Visible scintillation photodetector device incorporating chalcopyrite semiconductor crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stowe, Ashley C.; Burger, Arnold
2017-04-04
A photodetector device, including: a scintillator material operable for receiving incident radiation and emitting photons in response; a photodetector material coupled to the scintillator material operable for receiving the photons emitted by the scintillator material and generating a current in response, wherein the photodetector material includes a chalcopyrite semiconductor crystal; and a circuit coupled to the photodetector material operable for characterizing the incident radiation based on the current generated by the photodetector material. Optionally, the scintillator material includes a gamma scintillator material and the incident radiation received includes gamma rays. Optionally, the photodetector material is further operable for receiving thermalmore » neutrons and generating a current in response. The circuit is further operable for characterizing the thermal neutrons based on the current generated by the photodetector material.« less
Multi-mode radio frequency device
Gilbert, Ronald W [Morgan Hill, CA; Carrender, Curtis Lee [Morgan Hill, CA; Anderson, Gordon A [Benton City, WA; Steele, Kerry D [Kennewick, WA
2007-02-13
A transponder device having multiple modes of operation, such as an active mode and a passive mode, wherein the modes of operation are selected in response to the strength of a received radio frequency signal. A communication system is also provided having a transceiver configured to transmit a radio frequency signal and to receive a responsive signal, and a transponder configured to operate in a plurality of modes and to activate modes of operation in response to the radio frequency signal. Ideally, each mode of operation is activated and deactivated independent of the other modes, although two or more modes may be concurrently operational.
Application for managing model-based material properties for simulation-based engineering
Hoffman, Edward L [Alameda, CA
2009-03-03
An application for generating a property set associated with a constitutive model of a material includes a first program module adapted to receive test data associated with the material and to extract loading conditions from the test data. A material model driver is adapted to receive the loading conditions and a property set and operable in response to the loading conditions and the property set to generate a model response for the material. A numerical optimization module is adapted to receive the test data and the model response and operable in response to the test data and the model response to generate the property set.
Atnip, G W
1977-07-01
Separate groups of rats received 500 trials of lever-press training under autoshaping (food delivery followed 10-second lever presentations, or occurred immediately following a response); operant conditioning (responding was necessary for food delivery); and classical conditioning (food followed lever presentations regardless of responding). Each group then received 500 trials on an omission procedure in which food was omitted on trials with a response. Another group received 1000 trials on the omission procedure, and a fifth group, random control, received 1000 uncorrelated presentations of lever and food. The autoshaping, operant, and classical groups reached high response levels by the end of initial training. Acquisition was fastest in the autoshaping group. Responding remained consistently low in the control group. The omission group responded at a level between the control group and the other three groups. During omission training, responding in these three groups declined to the omission-group level. During omission training, the rats continued contacting the lever frequently after lever pressing had declined. Response maintenance under omission training seems not to require topographic similarity between the response and reinforcer-elicited consummatory behaviors.
Atnip, Gilbert W.
1977-01-01
Separate groups of rats received 500 trials of lever-press training under autoshaping (food delivery followed 10-second lever presentations, or occurred immediately following a response); operant conditioning (responding was necessary for food delivery); and classical conditioning (food followed lever presentations regardless of responding). Each group then received 500 trials on an omission procedure in which food was omitted on trials with a response. Another group received 1000 trials on the omission procedure, and a fifth group, random control, received 1000 uncorrelated presentations of lever and food. The autoshaping, operant, and classical groups reached high response levels by the end of initial training. Acquisition was fastest in the autoshaping group. Responding remained consistently low in the control group. The omission group responded at a level between the control group and the other three groups. During omission training, responding in these three groups declined to the omission-group level. During omission training, the rats continued contacting the lever frequently after lever pressing had declined. Response maintenance under omission training seems not to require topographic similarity between the response and reinforcer-elicited consummatory behaviors. PMID:16812014
Nada, Masahiro; Nakamura, Makoto; Matsuzaki, Hideaki
2014-01-13
25-Gbit/s error-free operation of an optical receiver is successfully demonstrated against burst-mode optical input signals without preambles. The receiver, with a high-sensitivity avalanche photodiode and burst-mode transimpedance amplifier, exhibits sufficient receiver sensitivity and an extremely quick response suitable for burst-mode operation in 100-Gbit/s optical packet switching.
Comparison of hypertonic saline versus normal saline on cytokine profile during CABG.
Mazandarani, Mahnaz; Yousefshahi, Fardin; Abdollahi, Mohammad; Hamishehkar, Hadi; Barkhordari, Khosro; Boroomand, Mohammad Ali; Jalali, Arash; Ahmadi, Arezoo; Moharari, Reza Shariat; Bashirzadeh, Mona; Mojtahedzadeh, Mojtaba
2012-10-08
Blood contact with artificial surfaces of the extracorporeal circuit and ischemia-reperfusion injury in CABG with CPB, may lead to a systemic inflammatory response. Hypertonic saline have been recently investigated as a fluid in order to decrease inflammatory response and cytokines generation in patients undergo cardiac operations. Our purpose is to study the prophylactic effect of HS 5% infusion versus NS on serum IL-6 as an inflammatory & IL-10 as an anti-inflammatory biomarker in CABG patients. The present study is a randomized double-blinded clinical trial. 40 patients undergoing CABG were randomized to receive HS 5% or NS before operation. Blood samples were obtained after receiving HS or NS, just before operation, 24 and 48 hours post-operatively. Plasma levels of IL-6 and IL-10 were measured by ELISA. Patients received HS had lower levels of IL-6 and higher level of IL-10 compared with NS group, however these differences were not statistically significant. Results of this study suggest that pre-treatment with small volume hypertonic saline 5% may have beneficial effects on inflammatory response following CABG operation.
Hardware support for software controlled fast multiplexing of performance counters
Salapura, Valentina; Wisniewski, Robert W
2013-10-01
Performance counters may be operable to collect one or more counts of one or more selected activities, and registers may be operable to store a set of performance counter configurations. A state machine may be operable to automatically select a register from the registers for reconfiguring the one or more performance counters in response to receiving a first signal. The state machine may be further operable to reconfigure the one or more performance counters based on a configuration specified in the selected register. The state machine yet further may be operable to copy data in selected one or more of the performance counters to a memory location, or to copy data from the memory location to the counters, in response to receiving a second signal. The state machine may be operable to store or restore the counter values and state machine configuration in response to a context switch event.
Hardware support for software controlled fast multiplexing of performance counters
Salapura, Valentina; Wisniewski, Robert W.
2013-01-01
Performance counters may be operable to collect one or more counts of one or more selected activities, and registers may be operable to store a set of performance counter configurations. A state machine may be operable to automatically select a register from the registers for reconfiguring the one or more performance counters in response to receiving a first signal. The state machine may be further operable to reconfigure the one or more performance counters based on a configuration specified in the selected register. The state machine yet further may be operable to copy data in selected one or more of the performance counters to a memory location, or to copy data from the memory location to the counters, in response to receiving a second signal. The state machine may be operable to store or restore the counter values and state machine configuration in response to a context switch event.
Radiant energy receiver having improved coolant flow control means
Hinterberger, H.
1980-10-29
An improved coolant flow control for use in radiant energy receivers of the type having parallel flow paths is disclosed. A coolant performs as a temperature dependent valve means, increasing flow in the warmer flow paths of the receiver, and impeding flow in the cooler paths of the receiver. The coolant has a negative temperature coefficient of viscosity which is high enough such that only an insignificant flow through the receiver is experienced at the minimum operating temperature of the receiver, and such that a maximum flow is experienced at the maximum operating temperature of the receiver. The valving is accomplished by changes in viscosity of the coolant in response to the coolant being heated and cooled. No remotely operated valves, comparators or the like are needed.
Comparison of hypertonic saline versus normal saline on cytokine profile during CABG
2012-01-01
Background and the purpose of the study Blood contact with artificial surfaces of the extracorporeal circuit and ischemia-reperfusion injury in CABG with CPB, may lead to a systemic inflammatory response. Hypertonic saline have been recently investigated as a fluid in order to decrease inflammatory response and cytokines generation in patients undergo cardiac operations. Our purpose is to study the prophylactic effect of HS 5% infusion versus NS on serum IL-6 as an inflammatory & IL-10 as an anti-inflammatory biomarker in CABG patients. Methods The present study is a randomized double-blinded clinical trial. 40 patients undergoing CABG were randomized to receive HS 5% or NS before operation. Blood samples were obtained after receiving HS or NS, just before operation, 24 and 48 hours post-operatively. Plasma levels of IL-6 and IL-10 were measured by ELISA. Results and major conclusion Patients received HS had lower levels of IL-6 and higher level of IL-10 compared with NS group, however these differences were not statistically significant. Results of this study suggest that pre-treatment with small volume hypertonic saline 5% may have beneficial effects on inflammatory response following CABG operation. PMID:23351427
NASA Astrophysics Data System (ADS)
Ishin, Artem; Voeykov, Sergey; Perevalova, Natalia; Khakhinov, Vitaliy
2017-12-01
As a part of the Plasma-Progress and Radar-Progress space experiments conducted from 2006 to 2014, effects of the Progress spacecraft engines on the ionosphere have been studied using data from Global Navigation Satellite System (GNSS) receivers. 72 experiments have been carried out. All these experiments were based on data from the International GNSS Service (IGS) to record ionospheric plasma irregularities caused by engine operation. 35 experiments used data from the ISTP SB RAS network SibNet. The analysis of the spatio-temporal structure of total electron content (TEC) variations has shown that the problem of identifying the TEC response to engine operation is complicated by a number of factors: 1) the engine effect on ionospheric plasma is strongly localized in space and has a relatively low intensity; 2) a small number of satellite-receiver radio rays due to the limited number of GNSS stations, particularly before 2013; 3) a potential TEC response is masked with background ionospheric disturbances of various intensities. However, TEC responses are identified with certainty when a satellite-receiver radio ray crosses a disturbed region within minutes after the impact. TEC responses have been registered in 7 experiments (10 % of cases). The amplitude of ionospheric response (0.3-0.16 TECU) exceeded the background TEC variations (~0.25 TECU) several times. The TEC data indicate that the ionospheric irregularity lifetime is from 4 to 10 minutes. According to the estimates we made, the transverse size of irregularities is from 12 to 30 km.
NASA Astrophysics Data System (ADS)
1982-07-01
Plant and system level operating instructions are provided for the Barstow Solar Pilot Plant. Individual status instructions are given that identify plant conditions, process controller responsibilities, process conditions and control accuracies, operating envelopes, and operator cautions appropriate to the operating condition. Transition operating instructions identify the sequence of activities to be carried out to accomplish the indicated transition. Most transitions involve the startup or shutdown of an individual flowpath. Background information is provided on collector field operations, and the heliostat groupings and specific commands used in support receiver startup are defined.
12 CFR 792.17 - What can I do if the time limit passes and I still have not received a response?
Code of Federal Regulations, 2014 CFR
2014-01-01
... still have not received a response? 792.17 Section 792.17 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR...
12 CFR 792.17 - What can I do if the time limit passes and I still have not received a response?
Code of Federal Regulations, 2012 CFR
2012-01-01
... still have not received a response? 792.17 Section 792.17 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR...
12 CFR 792.17 - What can I do if the time limit passes and I still have not received a response?
Code of Federal Regulations, 2013 CFR
2013-01-01
... still have not received a response? 792.17 Section 792.17 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR...
12 CFR 792.17 - What can I do if the time limit passes and I still have not received a response?
Code of Federal Regulations, 2011 CFR
2011-01-01
... still have not received a response? 792.17 Section 792.17 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR...
12 CFR 792.17 - What can I do if the time limit passes and I still have not received a response?
Code of Federal Regulations, 2010 CFR
2010-01-01
... still have not received a response? 792.17 Section 792.17 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR...
30 CFR 254.41 - Training your response personnel.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 254.41 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE OIL... the spill-response management team, including the spill-response coordinator and alternates, receives... strategies, and the operational and logistical requirements of response equipment; (2) Spill reporting...
23 CFR 710.201 - State responsibilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... REAL ESTATE Program Administration § 710.201 State responsibilities. (a) Organization. Each STD shall... responsibilities. (b) Program oversight. The STD shall have overall responsibility for the acquisition, management... Federal laws and regulations. (c) Right-of-way (ROW) operations manual. Each STD which receives funding...
23 CFR 710.201 - State responsibilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... REAL ESTATE Program Administration § 710.201 State responsibilities. (a) Organization. Each STD shall... responsibilities. (b) Program oversight. The STD shall have overall responsibility for the acquisition, management... Federal laws and regulations. (c) Right-of-way (ROW) operations manual. Each STD which receives funding...
76 FR 9039 - Emergency Responder Field Operations Guide
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-16
... Command System during incident operations. DATES: Comments must be received by March 18, 2011. ADDRESSES... (ER FOG) is intended for use when implementing the Incident Command System (ICS) in response to an...
The potential benefit of a home fire safety intervention during emergency medical services calls.
Pirrallo, R G; Rubin, J M; Murawsky, G A
1998-03-01
To determine how often house fires occur at 1- and 2-family dwellings visited previously by emergency medical services (EMS) personnel and whether these visits were missed opportunities for a point-of-contact home fire safety intervention. A retrospective, consecutive, case series analysis of all Milwaukee Fire Department alarm responses during 1994 was performed. Measurements included date of service, type of response, property type, dollar loss estimate, number of injuries and fatalities, cause of alarm, and presence of an operational smoke detector. Descriptive, chi2, and relative risk statistics were used to describe the relationship between EMS responses and fire responses at 1- and 2-family dwellings. The Milwaukee Fire Department dispatched 94,378 requests for service to 43,556 addresses. 16,150 addresses generated multiple requests; 7.2% (1,162/16,150) were for an "alarm of fire" response [relative risk 1.83 (95% CI: 1.69-1.99) for addresses with multiple requests vs those with a single request for service]. Most [62% (721/1,162)] of the addresses were visited by EMS personnel prior to the alarm; 28% (205/721) were 1- and 2-family dwellings. A mean of 1.8 (376/205) EMS responses occurred prior to the "alarm of fire" response; 121 addresses received 1 response, 46 received 2, 18 received 3, and 20 received > or = 4 responses. Of 169 addresses with complete data, there was a total fire dollar loss of $1,963,020 (1994) along with 32 injuries and 0 fatalities. While 47% (80/169) of the 1- and 2-family dwellings had a smoke detector present, only 17% (29/169) of the dwellings had an operational smoke detector. A point-of-contact home fire safety intervention appears of potential benefit for frequent users of EMS care. Determination of the presence of an operational smoke detector in 1- and 2-family dwellings may be a useful injury prevention act during such EMS calls.
25 CFR 142.3 - Who is responsible for the Alaska Resupply Operation?
Code of Federal Regulations, 2010 CFR
2010-04-01
... Alaska Resupply Operation, including the management of all facilities and equipment, personnel, and... conditions that must be published in a tariff. (b) All accounts receivable and accounts payable are handled...
25 CFR 142.3 - Who is responsible for the Alaska Resupply Operation?
Code of Federal Regulations, 2011 CFR
2011-04-01
... Alaska Resupply Operation, including the management of all facilities and equipment, personnel, and... conditions that must be published in a tariff. (b) All accounts receivable and accounts payable are handled...
25 CFR 142.3 - Who is responsible for the Alaska Resupply Operation?
Code of Federal Regulations, 2013 CFR
2013-04-01
... Alaska Resupply Operation, including the management of all facilities and equipment, personnel, and... conditions that must be published in a tariff. (b) All accounts receivable and accounts payable are handled...
25 CFR 142.3 - Who is responsible for the Alaska Resupply Operation?
Code of Federal Regulations, 2012 CFR
2012-04-01
... Alaska Resupply Operation, including the management of all facilities and equipment, personnel, and... conditions that must be published in a tariff. (b) All accounts receivable and accounts payable are handled...
25 CFR 142.3 - Who is responsible for the Alaska Resupply Operation?
Code of Federal Regulations, 2014 CFR
2014-04-01
... Alaska Resupply Operation, including the management of all facilities and equipment, personnel, and... conditions that must be published in a tariff. (b) All accounts receivable and accounts payable are handled...
Passive thermo-optic feedback for robust athermal photonic systems
Rakich, Peter T.; Watts, Michael R.; Nielson, Gregory N.
2015-06-23
Thermal control devices, photonic systems and methods of stabilizing a temperature of a photonic system are provided. A thermal control device thermally coupled to a substrate includes a waveguide for receiving light, an absorption element optically coupled to the waveguide for converting the received light to heat and an optical filter. The optical filter is optically coupled to the waveguide and thermally coupled to the absorption element. An operating point of the optical filter is tuned responsive to the heat from the absorption element. When the operating point is less than a predetermined temperature, the received light is passed to the absorption element via the optical filter. When the operating point is greater than or equal to the predetermined temperature, the received light is transmitted out of the thermal control device via the optical filter, without being passed to the absorption element.
Scott H. Stoleson; Todd E. Ristau; David S. deCalesta; Stephen B. Horsley
2011-01-01
Use of herbicides in forestry to direct successional trajectories has raised concerns over possible direct or indirect effects on non-target organisms. We studied the response of forest birds to an operational application of glyphosate and sulfometuron methyl herbicides, using a randomized block design in which half of each 8 ha block received herbicide and the other...
Shuttle GPS R/PA evaluation analysis and performance tradeoff study
NASA Technical Reports Server (NTRS)
Booth, R. W. D.; Lindsey, W. C.
1978-01-01
Primary responsibility was understanding and analyzing the various GPS receiver functions as they relate to the shuttle environment. These receiver functions included acquisition properties of the sequential detector, acquisition and tracking properties of the various receiver phase locked loops, and the techniques of sequential receiver operation. In addition to these areas, support was provided in the areas of oscillator stability requirements, antenna management, and navigation filter requirements, including preposition aiding.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-03
...In accordance with Section 122(i) of the Comprehensive Environmental Response, Compensation, and Liability Act, as amended (``CERCLA''), 42 U.S.C. 9622(i), notice is hereby given of a proposed administrative settlement for recovery of response costs concerning the North Hollywood Operable Unit of the San Fernando Valley Area 1 Superfund Site, located in the vicinity of Los Angeles, California, with the following settling party: Waste Management Recycling & Disposal Services of California, Inc., dba Bradley Landfill & Recycling Center. The settlement requires the settling party to pay a total of $185,734 to the North Hollywood Operable Unit Special Account within the Hazardous Substance Superfund. The settlement also includes a covenant not to sue the settling party pursuant to Section 107(a) of CERCLA, 42 U.S.C. 9607(a). For thirty (30) days following the date of publication of this notice, the Agency will receive written comments relating to the settlement. The Agency will consider all comments received and may modify or withdraw its consent to the settlement if comments received disclose facts or considerations which indicate that the settlement is inappropriate, improper, or inadequate. The Agency's response to any comments received will be available for public inspection at the City of Los Angeles Central Library, Science and Technology Department, 630 West 5th Street, Los Angeles CA 90071 and at the EPA Region 9 Superfund Records Center, Mail Stop SFD-7C, 95 Hawthorne Street, Room 403, San Francisco, CA 94105.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-13
...In accordance with Section 122(i) of the Comprehensive Environmental Response, Compensation, and Liability Act, as amended (``CERCLA''), 42 U.S.C. 9622(i), notice is hereby given of a proposed administrative settlement for recovery of response costs concerning the North Hollywood Operable Unit of the San Fernando Valley Area 1 Superfund Site, located in the vicinity of Los Angeles, California, with the following settling parties: Pick-Your-Part Auto Wrecking; Hayward Associates, LLC; and PNM Properties, LLC. The settlement requires the settling parties to pay a total of $102,161 to the North Hollywood Operable Unit Special Account within the Hazardous Substance Superfund. The settlement also includes a covenant not to sue the settling parties pursuant to Section 107(a) of CERCLA, 42 U.S.C. 9607(a). For thirty (30) days following the date of publication of this notice, the Agency will receive written comments relating to the settlement. The Agency will consider all comments received and may modify or withdraw its consent to the settlement if comments received disclose facts or considerations which indicate that the settlement is inappropriate, improper, or inadequate. The Agency's response to any comments received will be available for public inspection at the City of Los Angeles Central Library, Science and Technology Department, 630 West 5th Street, Los Angeles, CA 90071 and at the EPA Region 9 Superfund Records Center, Mail Stop SFD-7C, 95 Hawthorne Street, Room 403, San Francisco, CA 94105.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-22
...In accordance with Section 122(i) of the Comprehensive Environmental Response, Compensation, and Liability Act, as amended (``CERCLA''), 42 U.S.C. 9622(i), notice is hereby given of a proposed administrative settlement for recovery of response costs concerning the North Hollywood Operable Unit of the San Fernando Valley Area 1 Superfund Site, located in the vicinity of Los Angeles, California, with the following settling parties: Pick-Your-Part Auto Wrecking; Hayward Associates, LLC; and PNM Properties, LLC. The settlement requires the settling parties to pay a total of $102,161 to the North Hollywood Operable Unit Special Account within the Hazardous Substance Superfund. The settlement also includes a covenant not to sue the settling parties pursuant to Section 107(a) of CERCLA, 42 U.S.C. 9607(a). For thirty (30) days following the date of publication of this notice, the Agency will receive written comments relating to the settlement. The Agency will consider all comments received and may modify or withdraw its consent to the settlement if comments received disclose facts or considerations which indicate that the settlement is inappropriate, improper, or inadequate. The Agency's response to any comments received will be available for public inspection at the City of Los Angeles Central Library, Science and Technology Department, 630 West 5th Street, Los Angeles, CA 90071 and at the EPA Region 9 Superfund Records Center, Mail Stop SFD-7C, 95 Hawthorne Street, Room 403, San Francisco, CA 94105.
12 CFR 792.28 - What if I am not satisfied with the response I receive?
Code of Federal Regulations, 2012 CFR
2012-01-01
... receive? 792.28 Section 792.28 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR CLASSIFIED...
12 CFR 792.28 - What if I am not satisfied with the response I receive?
Code of Federal Regulations, 2011 CFR
2011-01-01
... receive? 792.28 Section 792.28 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR CLASSIFIED...
12 CFR 792.28 - What if I am not satisfied with the response I receive?
Code of Federal Regulations, 2013 CFR
2013-01-01
... receive? 792.28 Section 792.28 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR CLASSIFIED...
12 CFR 792.28 - What if I am not satisfied with the response I receive?
Code of Federal Regulations, 2010 CFR
2010-01-01
... receive? 792.28 Section 792.28 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR CLASSIFIED...
12 CFR 792.28 - What if I am not satisfied with the response I receive?
Code of Federal Regulations, 2014 CFR
2014-01-01
... receive? 792.28 Section 792.28 Banks and Banking NATIONAL CREDIT UNION ADMINISTRATION REGULATIONS AFFECTING THE OPERATIONS OF THE NATIONAL CREDIT UNION ADMINISTRATION REQUESTS FOR INFORMATION UNDER THE FREEDOM OF INFORMATION ACT AND PRIVACY ACT, AND BY SUBPOENA; SECURITY PROCEDURES FOR CLASSIFIED...
77 FR 24687 - Impact of Overdraft Programs on Consumers
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-25
..., is extended. Responses must now be received on or before June 29, 2012. ADDRESSES: You may submit...' operating policies; The economics of overdraft programs; and Long-term impacts on Consumers. The comment... period allotted for comments received pursuant to the Overdraft Notice. The comment period will now close...
Qin, Heng; Zuo, Yong; Zhang, Dong; Li, Yinghui; Wu, Jian
2017-03-06
Through slight modification on typical photon multiplier tube (PMT) receiver output statistics, a generalized received response model considering both scattered propagation and random detection is presented to investigate the impact of inter-symbol interference (ISI) on link data rate of short-range non-line-of-sight (NLOS) ultraviolet communication. Good agreement with the experimental results by numerical simulation is shown. Based on the received response characteristics, a heuristic check matrix construction algorithm of low-density-parity-check (LDPC) code is further proposed to approach the data rate bound derived in a delayed sampling (DS) binary pulse position modulation (PPM) system. Compared to conventional LDPC coding methods, better bit error ratio (BER) below 1E-05 is achieved for short-range NLOS UVC systems operating at data rate of 2Mbps.
Advanced development receiver thermal vacuum tests with cold wall
NASA Technical Reports Server (NTRS)
Sedgwick, Leigh M.
1991-01-01
The first ever testing of a full size solar dynamic heat receiver using high temperature thermal energy storage was completed. The heat receiver was designed to meet the requirements for operation on the Space Station Freedom. The purpose of the test program was to quantify the receiver thermodynamic performance, its operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber with liquid nitrogen cold shrouds and an aperture cold plate to partially simulate a low Earth orbit environment. The cavity of the receiver was heated by an infrared quartz lamp heater with 30 independently controllable zones to produce flux distributions typical of candidate concentrators. A closed Brayton cycle engine simulator conditioned a helium xenon gas mixture to specific interface conditions to simulate various operational modes of the solar dynamic power module. Inlet gas temperature, pressure, and flow rate were independently varied. A total of 58 simulated orbital cycles were completed during the test conduct period. The test hardware, execution of testing, test data, and post test inspections are described.
Pacing a data transfer operation between compute nodes on a parallel computer
Blocksome, Michael A [Rochester, MN
2011-09-13
Methods, systems, and products are disclosed for pacing a data transfer between compute nodes on a parallel computer that include: transferring, by an origin compute node, a chunk of an application message to a target compute node; sending, by the origin compute node, a pacing request to a target direct memory access (`DMA`) engine on the target compute node using a remote get DMA operation; determining, by the origin compute node, whether a pacing response to the pacing request has been received from the target DMA engine; and transferring, by the origin compute node, a next chunk of the application message if the pacing response to the pacing request has been received from the target DMA engine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Covered are: analytical laboratory operations (ALO) sample receipt and control, ALO data report/package preparation review and control, single shell tank (PST) project sample tracking system, sample receiving, analytical balances, duties and responsibilities of sample custodian, sample refrigerator temperature monitoring, security, assignment of staff responsibilities, sample storage, data reporting, and general requirements for glassware.
Resonant ultrasound spectrometer
Migliori, Albert; Visscher, William M.; Fisk, Zachary
1990-01-01
An ultrasound resonant spectrometer determines the resonant frequency spectrum of a rectangular parallelepiped sample of a high dissipation material over an expected resonant response frequency range. A sample holder structure grips corners of the sample between piezoelectric drive and receive transducers. Each transducer is mounted on a membrane for only weakly coupling the transducer to the holder structure and operatively contacts a material effective to remove system resonant responses at the transducer from the expected response range. i.e., either a material such as diamond to move the response frequencies above the range or a damping powder to preclude response within the range. A square-law detector amplifier receives the response signal and retransmits the signal on an isolated shield of connecting cabling to remove cabling capacitive effects. The amplifier also provides a substantially frequency independently voltage divider with the receive transducer. The spectrometer is extremely sensitive to enable low amplitude resonance to be detected for use in calculating the elastic constants of the high dissipation sample.
Forward-biased nanophotonic detector for ultralow-energy dissipation receiver
NASA Astrophysics Data System (ADS)
Nozaki, Kengo; Matsuo, Shinji; Fujii, Takuro; Takeda, Koji; Shinya, Akihiko; Kuramochi, Eiichi; Notomi, Masaya
2018-04-01
Generally, reverse-biased photodetectors (PDs) are used for high-speed optical receivers. The forward voltage region is only utilized in solar-cells, and this photovoltaic operation would not be concurrently obtained with high efficiency and high speed operation. Here we report that photonic-crystal waveguide PDs enable forward-biased high-speed operation at 40 Gbit/s with keeping high responsivity (0.88 A/W). Within our knowledge, this is the first demonstration of the forward-biased PDs with high responsivity. This achievement is attributed to the ultracompactness of our PD and the strong light confinement within the absorber and depleted regions, thereby enabling efficient photo-carrier generation and fast extraction. This result indicates that it is possible to construct a high-speed and ultracompact photo-receiver without an electrical amplifier nor an external bias circuit. Since there is no electrical energy required, our estimation shows that the consumption energy is just the optical energy of the injected signal pulse which is about 1 fJ/bit. Hence, it will lead to an ultimately efficient and highly integrable optical-to-electrical converter in a chip, which will be a key ingredient for dense nanophotonic communication and processors.
NASA Astrophysics Data System (ADS)
Brovchenko, Mariya; Duhamel, Isabelle; Dechenaux, Benjamin
2017-09-01
The present paper presents the study carried out in the frame of the DISCOMS project, which stands for "DIstributed Sensing for COrium Monitoring and Safety". This study concerns the calculation of the neutron and gamma radiations received by the considered instrumentation during the normal reactor operation as well as in case of a severe accident for the EPR reactor, outside the reactor pressure vessel and in the containment basemat. This paper summarizes the methods and hypotheses used for the particle transport simulation outside the vessel during normal reactor operation. The results of the simulations are then presented including the responses for distributed Optical Fiber Sensors (OFS), such as the gamma dose and the fast neutron fluence, and for Self Powered Neutron Detectors (SPNDs), namely the neutron and gamma spectra. Same responses are also evaluated for severe accident situations in order to design the SPNDs being sensitive to the both types of received neutron-gamma radiation. By contrast, fibers, involved as transducers in distributed OFS have to resist to the total radiation gamma dose and neutron fluence received during normal operation and the severe accident.
49 CFR 40.349 - What records may a service agent receive and maintain?
Code of Federal Regulations, 2010 CFR
2010-10-01
... TRANSPORTATION WORKPLACE DRUG AND ALCOHOL TESTING PROGRAMS Roles and Responsibilities of Service Agents § 40.349... part, as a service agent you may receive and maintain all records concerning DOT drug and alcohol... needed for operating a drug/alcohol program (e.g., CCFs, ATFs, names of employees in random pools, random...
2016-01-01
carpentry, masonry , and the operation of heavy equipment. Plans called for the NEB to receive at least $29 million in engineering equipment and...JTF Sapper, NMCB 25, and NMCB 28, had responsibility for training the NEB in such areas as plumbing, electrical work, carpentry, masonry , and
Attitudes of Operative Dentistry Faculty toward Rubber Dam Isolation.
ERIC Educational Resources Information Center
Brackett, William W.; And Others
1989-01-01
Dental faculty responses (N=332) to a survey concerning use of rubber dams for excluding fluids from the working field in operative dentistry procedures indicated students receive adequate instruction in rubber dam use and are proficient at graduation, though motivating students to its use is problematic and patient resistance a factor. (MSE)
Low latency, high bandwidth data communications between compute nodes in a parallel computer
Blocksome, Michael A
2014-04-01
Methods, systems, and products are disclosed for data transfers between nodes in a parallel computer that include: receiving, by an origin DMA on an origin node, a buffer identifier for a buffer containing data for transfer to a target node; sending, by the origin DMA to the target node, a RTS message; transferring, by the origin DMA, a data portion to the target node using a memory FIFO operation that specifies one end of the buffer from which to begin transferring the data; receiving, by the origin DMA, an acknowledgement of the RTS message from the target node; and transferring, by the origin DMA in response to receiving the acknowledgement, any remaining data portion to the target node using a direct put operation that specifies the other end of the buffer from which to begin transferring the data, including initiating the direct put operation without invoking an origin processing core.
Low latency, high bandwidth data communications between compute nodes in a parallel computer
Blocksome, Michael A
2014-04-22
Methods, systems, and products are disclosed for data transfers between nodes in a parallel computer that include: receiving, by an origin DMA on an origin node, a buffer identifier for a buffer containing data for transfer to a target node; sending, by the origin DMA to the target node, a RTS message; transferring, by the origin DMA, a data portion to the target node using a memory FIFO operation that specifies one end of the buffer from which to begin transferring the data; receiving, by the origin DMA, an acknowledgement of the RTS message from the target node; and transferring, by the origin DMA in response to receiving the acknowledgement, any remaining data portion to the target node using a direct put operation that specifies the other end of the buffer from which to begin transferring the data, including initiating the direct put operation without invoking an origin processing core.
Low latency, high bandwidth data communications between compute nodes in a parallel computer
Blocksome, Michael A
2013-07-02
Methods, systems, and products are disclosed for data transfers between nodes in a parallel computer that include: receiving, by an origin DMA on an origin node, a buffer identifier for a buffer containing data for transfer to a target node; sending, by the origin DMA to the target node, a RTS message; transferring, by the origin DMA, a data portion to the target node using a memory FIFO operation that specifies one end of the buffer from which to begin transferring the data; receiving, by the origin DMA, an acknowledgement of the RTS message from the target node; and transferring, by the origin DMA in response to receiving the acknowledgement, any remaining data portion to the target node using a direct put operation that specifies the other end of the buffer from which to begin transferring the data, including initiating the direct put operation without invoking an origin processing core.
Advanced capability RFID system
Gilbert, Ronald W.; Steele, Kerry D.; Anderson, Gordon A.
2007-09-25
A radio-frequency transponder device having an antenna circuit configured to receive radio-frequency signals and to return modulated radio-frequency signals via continuous wave backscatter, a modulation circuit coupled to the antenna circuit for generating the modulated radio-frequency signals, and a microprocessor coupled to the antenna circuit and the modulation circuit and configured to receive and extract operating power from the received radio-frequency signals and to monitor inputs on at least one input pin and to generate responsive signals to the modulation circuit for modulating the radio-frequency signals. The microprocessor can be configured to generate output signals on output pins to associated devices for controlling the operation thereof. Electrical energy can be extracted and stored in an optional electrical power storage device.
A Comparison of Responsive Interventions on Kindergarteners' Early Reading Achievement
ERIC Educational Resources Information Center
Little, Mary E.; Rawlinson, D'Ann; Simmons, Deborah C.; Kim, Minjung; Kwok, Oi-man; Hagan-Burke, Shanna; Simmons, Leslie E.; Fogarty, Melissa; Oslund, Eric; Coyne, Michael D.
2012-01-01
This study compared the effects of Tier 2 reading interventions that operated in response-to-intervention contexts. Kindergarten children (N = 90) who were identified as at risk for reading difficulties were stratified by school and randomly assigned to receive (a) Early Reading Intervention (ERI; Pearson/Scott Foresman, 2004) modified in response…
Billing and accounts receivable: fundamentals for improvement.
Bizon, M M
1993-07-01
If a healthcare facility's accounts receivable operation is experiencing problems, the patient accounts manager should survey all areas of his or her responsibility to determine the best method of resolving the difficulties. One effective technique to reduce billing problems is to take a proactive--not reactive--approach. If mistakes can be corrected before they get out of control, and if the patient accounts manager can ensure that claims will not be denied, a healthcare facility's accounts receivable should remain in good condition.
Development of a prototype real-time automated filter for operational deep space navigation
NASA Technical Reports Server (NTRS)
Masters, W. C.; Pollmeier, V. M.
1994-01-01
Operational deep space navigation has been in the past, and is currently, performed using systems whose architecture requires constant human supervision and intervention. A prototype for a system which allows relatively automated processing of radio metric data received in near real-time from NASA's Deep Space Network (DSN) without any redesign of the existing operational data flow has been developed. This system can allow for more rapid response as well as much reduced staffing to support mission navigation operations.
Thompson, J; Hogg, P; Thompson, S; Manning, D; Szczepura, K
2012-01-01
ROCView has been developed as an image display and response capture (IDRC) solution to image display and consistent recording of reader responses in relation to the free-response receiver operating characteristic paradigm. A web-based solution to IDRC for observer response studies allows observations to be completed from any location, assuming that display performance and viewing conditions are consistent with the study being completed. The simplistic functionality of the software allows observations to be completed without supervision. ROCView can display images from multiple modalities, in a randomised order if required. Following registration, observers are prompted to begin their image evaluation. All data are recorded via mouse clicks, one to localise (mark) and one to score confidence (rate) using either an ordinal or continuous rating scale. Up to nine “mark-rating” pairs can be made per image. Unmarked images are given a default score of zero. Upon completion of the study, both true-positive and false-positive reports can be downloaded and adapted for analysis. ROCView has the potential to be a useful tool in the assessment of modality performance difference for a range of imaging methods. PMID:22573294
Full-size solar dynamic heat receiver thermal-vacuum tests
NASA Technical Reports Server (NTRS)
Sedgwick, L. M.; Kaufmann, K. J.; Mclallin, K. L.; Kerslake, Thomas W.
1991-01-01
The testing of a full-size, 120 kW, solar dynamic heat receiver utilizing high-temperature thermal energy storage is described. The purpose of the test program was to quantify receiver thermodynamic performance, operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber with liquid nitrogen cold shrouds and an aperture cold plate to partly simulate a low-Earth-orbit environment. The cavity of the receiver was heated by an infrared quartz lamp heater with 30 independently controllable zones to allow axially and circumferentially varied flux distributions. A closed-Brayton cycle engine simulator conditioned a helium-xenon gas mixture to specific interface conditions to simulate the various operational modes of the solar dynamic power module on the Space Station Freedom. Inlet gas temperature, pressure, and flow rate were independently varied. A total of 58 simulated orbital cycles, each 94 minutes in duration, was completed during the test conduct period.
Full-size solar dynamic heat receiver thermal-vacuum tests
NASA Technical Reports Server (NTRS)
Sedgwick, L. M.; Kaufmann, K. J.; Mclallin, K. L.; Kerslake, T. W.
1991-01-01
The testing of a full-size, 102 kW, solar dynamic heat receiver utilizing high-temperature thermal energy storage is described. The purpose of the test program was to quantify receiver thermodynamic performance, operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber with liquid nitrogen cold shrouds and an aperture cold plate to partly simulate a low-Earth-orbit environment. The cavity of the receiver was heated by an infrared quartz lamp heater with 30 independently controllable zones to allow axially and circumferentially varied flux distributions. A closed-Brayton cycle engine simulator conditioned a helium-xenon gas mixture to specific interface conditions to simulate the various operational modes of the solar dynamic power module on the Space Station Freedom. Inlet gas temperature, pressure, and flow rate were independently varied. A total of 58 simulated orbital cycles, each 94 minutes in duration, was completed during the test period.
Full-size solar dynamic heat receiver thermal-vacuum tests
NASA Astrophysics Data System (ADS)
Sedgwick, L. M.; Kaufmann, K. J.; McLallin, K. L.; Kerslake, T. W.
The testing of a full-size, 102 kW, solar dynamic heat receiver utilizing high-temperature thermal energy storage is described. The purpose of the test program was to quantify receiver thermodynamic performance, operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber with liquid nitrogen cold shrouds and an aperture cold plate to partly simulate a low-Earth-orbit environment. The cavity of the receiver was heated by an infrared quartz lamp heater with 30 independently controllable zones to allow axially and circumferentially varied flux distributions. A closed-Brayton cycle engine simulator conditioned a helium-xenon gas mixture to specific interface conditions to simulate the various operational modes of the solar dynamic power module on the Space Station Freedom. Inlet gas temperature, pressure, and flow rate were independently varied. A total of 58 simulated orbital cycles, each 94 minutes in duration, was completed during the test period.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-03
...- AK03 Removal of Category IIIa, IIIb, and IIIc Definitions; Confirmation of Effective Date and Response... received on that direct final rule. In that document, the FAA proposed to remove the definitions of Category IIIa, IIIb, and IIIc operations because the definitions are outdated and no longer used for...
NASA Technical Reports Server (NTRS)
Grimes, Craig A. (Inventor); Stoyanov, Plamen G. (Inventor)
2002-01-01
An analyte, viscosity, or temperature sensing apparatus for operative arrangement within a time-varying magnetic field, including a sensor with an outer surface that is chemically, frictionally, or thermally responsive and adhered to a base magnetostrictive element, and a receiver to measure a first and second value for magneto-elastic emission intensity of the sensor taken at, respectively, a first and second interrogation frequency. A change in mass or a change in material stiffness of the sensor due to the responsiveness, the viscosity and mass density of a fluid therearound, or the temperature, can be identified. The receiver, alternatively, measures a plurality of successive values for magneto-elastic emission intensity of the sensor taken over an operating range of successive interrogation frequencies to identify a value for the sensor's magneto-elastic resonant frequency (a fundamental frequency or harmonic thereof). Several sensors in an ordered array will provide a package of information.
Apparatuses and method for converting electromagnetic radiation to direct current
Kotter, Dale K; Novack, Steven D
2014-09-30
An energy conversion device may include a first antenna and a second antenna configured to generate an AC current responsive to incident radiation, at least one stripline, and a rectifier coupled with the at least one stripline along a length of the at least one stripline. An energy conversion device may also include an array of nanoantennas configured to generate an AC current in response to receiving incident radiation. Each nanoantenna of the array includes a pair of resonant elements, and a shared rectifier operably coupled to the pair of resonant elements, the shared rectifier configured to convert the AC current to a DC current. The energy conversion device may further include a bus structure operably coupled with the array of nanoantennas and configured to receive the DC current from the array of nanoantennas and transmit the DC current away from the array of nanoantennas.
Hashida, Masahiro; Kamezaki, Ryousuke; Goto, Makoto; Shiraishi, Junji
2017-03-01
The ability to predict hazards in possible situations in a general X-ray examination room created for Kiken-Yochi training (KYT) is quantified by use of free-response receiver-operating characteristics (FROC) analysis for determining whether the total number of years of clinical experience, involvement in general X-ray examinations, occupation, and training each have an impact on the hazard prediction ability. Twenty-three radiological technologists (RTs) (years of experience: 2-28), four nurses (years of experience: 15-19), and six RT students observed 53 scenes of KYT: 26 scenes with hazardous points (hazardous points are those that might cause injury to patients) and 27 scenes without points. Based on the results of these observations, we calculated the alternative free-response receiver-operating characteristic (AFROC) curve and the figure of merit (FOM) to quantify the hazard prediction ability. The results showed that the total number of years of clinical experience did not have any impact on hazard prediction ability, whereas recent experience with general X-ray examinations greatly influenced this ability. In addition, the hazard prediction ability varied depending on the occupations of the observers while they were observing the same scenes in KYT. The hazard prediction ability of the radiologic technology students was improved after they had undergone patient safety training. This proposed method with FROC observer study enabled the quantification and evaluation of the hazard prediction capability, and the application of this approach to clinical practice may help to ensure the safety of examinations and treatment in the radiology department.
Kho, H G; Kloppenborg, P W; van Egmond, J
1993-05-01
The effects of acupuncture and transcutaneous electrical stimulation (TES) on plasma adrenaline (A) and noradrenaline (NA), adrenocorticotropic hormone (ACTH), beta-endorphin (beta E), anti-diuretic hormone (ADH) and hydrocortisone (cortisol) were evaluated during and, for four days after surgery in 42 male patients submitted to a standardized major abdominal operation in a comparative study of three different anaesthetic techniques. Group 1 received acupuncture and transcutaneous stimulation as the main non-pharmacological analgesic during surgery. Group 2 received moderate-dose fentanyl (initial bolus of 10 micrograms kg-1 followed by continuous infusion of 5 micrograms kg-1 h-1 for the first hour, and then 4 micrograms kg-1 h-1. Group 3 received a combination of both methods. In all three groups analgesia was supplemented, if necessary, by small bolus injections of 50 micrograms fentanyl. Anaesthesia was induced in all groups with thiopentone 5 mg kg-1 and vecuronium 0.1 mg kg-1 and patients were ventilated (N2O:O2 = 2:1) to achieve normocapnia without the use of a halogenated agent. Pre-operatively acupuncture plus TES in Groups 1 and 3 led to a rise in beta E (P < 0.05) without changes of haemodynamics. After intubation beta E did not increase further. Intubation in Group 2 led to an increase of beta E (P < 0.05) also, and to a rise in pulse rate and blood pressure (P < 0.05) in all three groups. Per-operatively acupuncture plus TES in Group 1 showed a response of circulating NA and cortisol similar to that in Groups 2 and 3, whereas the responses of the circulating A, ACTH, beta E and ADH in Group 1 were more pronounced (P < 0.01). Post-operatively no differences in the hormonal profiles could be discerned between the groups with or without acupuncture plus TES (Group 2 vs. Group 3) nor between those with or without moderate-dose fentanyl anaesthesia (Group 1 vs. Group 3). It is concluded that acupuncture and TES have no effect on the cardiovascular response to laryngoscopy and intubation. They can replace moderate-dose fentanyl anaesthesia in major abdominal surgery at the cost of a more enhanced per-operative neuroendocrine stress response, which does not, however, influence the postoperative hormonal profiles nor the rapidity of return to pre-operative values.
Kudravetz, M.K.; Greene, H.B.
1958-09-16
This patent relates to control systems for a calutron and, in particular, describes an electro-mechanical system for interrupting the collection of charged particles when the ratio between the two isotopes being receivcd deviates from a predetermined value. One embodiment of the invention includes means responsive to the ratio between two isotopes being received for opening a normally closed shutter over the receiver entrance when the isotope ratio is the desired value. In another form of the invention the collection operation is interrupted by changing the beam accelerating voltage to deflect the ion beam away from the receiver.
Singla, Neil; Rock, Amy; Pavliv, Leo
2010-01-01
Objective To determine whether pre- and post-operative administration of intravenous ibuprofen (IV-ibuprofen) can significantly decrease pain and morphine use when compared with placebo in adult orthopedic surgical patients. Design This was a multi-center, randomized, double-blind placebo-controlled trial. Setting This study was completed at eight hospitals; six in the United States and two in South Africa. Patients A total of 185 adult patients undergoing elective orthopedic surgery. Interventions Patients were randomized to receive either 800 mg IV-ibuprofen or placebo every 6 hours, with the first dose administered pre-operatively. Additionally, all patients had access to intravenous morphine for rescue. Outcome Measures Efficacy of IV-ibuprofen was demonstrated by measuring the patient's self assessment of pain using a visual analog scale (VAS; assessed with movement and at rest) and a verbal response scale (VRS). Morphine consumption during the post-operative period was also assessed. Results In the immediate post-operative period, there was a 25.8% reduction in mean area under the curve-VAS assessed with movement (AUC-VASM) in patients receiving IV-ibuprofen (P < 0.001); a 31.8% reduction in mean AUC-VAS assessed at rest (AUC-VASR; P < 0.001) and a 20.2% reduction in mean VRS (P < 0.001) compared to those receiving placebo. Patients receiving IV-ibuprofen used 30.9% less morphine (P < 0.001) compared to those receiving placebo. Similar treatment emergent adverse events occurred in both study groups and there were no significant differences in the incidence of serious adverse events. Conclusion Pre- and post-operative administration of IV-ibuprofen significantly reduced both pain and morphine use in orthopedic surgery patients in this prospective randomized placebo-controlled trial. PMID:20609131
Intraperitoneal photodynamic therapy for peritoneal carcinomatosis and sarcomatosis
NASA Astrophysics Data System (ADS)
Hahn, Stephen M.; Fraker, Douglas L.; Zhu, Timothy C.; Yodh, Arjun G.; Rodriguez, Carmen E.; Smith, Debbie; Currens, Ann; Glatstein, Eli
2000-03-01
The preliminary results of an ongoing Phase II trial of Photofrin-mediated intraperitoneal PDT (IP PDT) are presented. The clinical endpoints of this trial are to determine the response rates of patients with carcinomatosis and sarcomatosis to IP PDT and to document the toxicities of IP PDT in a defined patient population. Photofrin, 2.5 mg/kg, was administered intravenously 48 hours prior to debulking surgery and light delivery, 57 patients with ovarian cancer, gastrointestinal cancers, and sarcomas were enrolled. 44 patients received Photofrin and received light treatment. 39 patients are valuable for response. 8 of 39 patients had a complete radiographic response to IP PDT 3 months after treatment. 3 patients are alive without evidence of disease 6, 6 and 9 months after treatment. 1 patient is alive and has no evidence of intra-abdominal disease but has developed lung metastases. Toxicities include post-operative fluid shifts, hypotension, hydronephrosis, pleural effusions, enteric fistula, transient liver function test elevation, thrombocytopenia, and wound dehiscence. Toxicity is related to pre-operative tumor bulk and to the extensiveness of surgery required. IP PDT is feasible and leads to an initial clinical response rate of 25 percent in patients with incurable peritoneal carcinomatosis and sarcomatosis.
Density and delay of punishment of free-operant avoidance1
Baron, Alan; Kaufman, Arnold; Fazzini, Dan
1969-01-01
In two experiments, the free-operant shock-avoidance behavior of rats was punished by electric shock. Two aspects of the schedule of response-produced shock were varied: the frequency of punishment over time (punishment density) and the temporal interval between the punished response and the punishment (punishment delay). The general finding was that response-produced shock suppressed avoidance responding under most of the density-delay combinations studied, and suppression increased as a function of increases in density and decreases in delay. Rate increases of small magnitude also were observed, usually as an initial reaction to the lesser densities and longer delays. Response suppression, while decreasing the number of punishment shocks received, also increased the number of avoidance shocks, so that the total number of shocks received usually was greater than the minimal number possible. The results were discussed from the standpoint of similarities between the effects of punishing positively and negatively reinforced behavior. The finding that subjects did not minimize the total number of shocks suggested that when avoidance behavior is punished, responding is controlled more by the local consequences of responding than by overall shock frequencies during the course of the session. PMID:16811408
Method and apparatus for the measurement of signals from radiation sensors
De Geronimo, Gianluigi
2012-09-18
The preferred embodiments of the present invention include a device for measuring an ionizing event in a radiation sensor. The device can include a charge amplifier and a timing shaper. The charge amplifier receives a cathode signal and is configured to output an amplified cathode signal. The timing shaper is operatively connected to the charge amplifier to receive the amplified cathode signal. The timing shaper is configured to generate a first pulse in response to a beginning of the ionizing event and a second pulse in response to an end of the ionizing event. The first and second pulses are associated with a depth of interaction of the ionizing event and are generated in response to a slope of the amplified cathode signal changing.
System for controlling the operating temperature of a fuel cell
Fabis, Thomas R.; Makiel, Joseph M.; Veyo, Stephen E.
2006-06-06
A method and system are provided for improved control of the operating temperature of a fuel cell (32) utilizing an improved temperature control system (30) that varies the flow rate of inlet air entering the fuel cell (32) in response to changes in the operating temperature of the fuel cell (32). Consistent with the invention an improved temperature control system (30) is provided that includes a controller (37) that receives an indication of the temperature of the inlet air from a temperature sensor (39) and varies the heat output by at least one heat source (34, 36) to maintain the temperature of the inlet air at a set-point T.sub.inset. The controller (37) also receives an indication of the operating temperature of the fuel cell (32) and varies the flow output by an adjustable air mover (33), within a predetermined range around a set-point F.sub.set, in order to maintain the operating temperature of the fuel cell (32) at a set-point T.sub.opset.
NASA aviation safety reporting system
NASA Technical Reports Server (NTRS)
1976-01-01
During the second quarter of the Aviation Safety Reporting System (ASRS) operation, 1,497 reports were received from pilots, controllers, and others in the national aviation system. Details of the administration and results of the program to date are presented. Examples of alert bulletins disseminated to the aviation community are presented together with responses to those bulletins. Several reports received by ASRS are also presented to illustrate the diversity of topics covered by reports to the system.
77 FR 53882 - Combined Notice of Filings #2
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-04
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 2 Take notice that the Commission received the following electric rate filings: Docket Numbers: ER12-1928-000. Applicants: Midwest Independent Transmission System Operator, Inc. Description: Response of Midwest...
Sear, Rose; Rees, Jeremy; Buller, Zairah; Moore, Simon C
2018-05-01
To assess the feasibility of using short message service text messages to solicit dental patients' experiences of post-operative dental discomfort and sensitivity (PODDS) and whether responses characterise change in PODDS over time. Patients were recruited from clinics following routine dental procedures, such as simple restorations or root surface debridement. They completed a short questionnaire collecting information on socio-economic circumstances, their recent experience of PODDS, the acceptability of receiving text message questions and their telephone number. Participants received a short question by text to their telephone for five consecutive days that asked them to respond with an indication (on a 1 to 10 scale) of their experience of PODDS at that time. Questionnaires were completed by 34 participants, of whom text message responses were received from an average of 23.4 participants (min 20, max 26) across the five follow-up days. Regression analyses indicated that PODDS decreased over time (β = -0.24, 95% CI -0.36 to -0.12). Text messaging to solicit PODDS is feasible and can potentially be used to assess the efficacy of treatments designed to minimise or reduce PODDS. Copyright © 2018 Elsevier Ltd. All rights reserved.
MATLAB/Simulink Pulse-Echo Ultrasound System Simulator Based on Experimentally Validated Models.
Kim, Taehoon; Shin, Sangmin; Lee, Hyongmin; Lee, Hyunsook; Kim, Heewon; Shin, Eunhee; Kim, Suhwan
2016-02-01
A flexible clinical ultrasound system must operate with different transducers, which have characteristic impulse responses and widely varying impedances. The impulse response determines the shape of the high-voltage pulse that is transmitted and the specifications of the front-end electronics that receive the echo; the impedance determines the specification of the matching network through which the transducer is connected. System-level optimization of these subsystems requires accurate modeling of pulse-echo (two-way) response, which in turn demands a unified simulation of the ultrasonics and electronics. In this paper, this is realized by combining MATLAB/Simulink models of the high-voltage transmitter, the transmission interface, the acoustic subsystem which includes wave propagation and reflection, the receiving interface, and the front-end receiver. To demonstrate the effectiveness of our simulator, the models are experimentally validated by comparing the simulation results with the measured data from a commercial ultrasound system. This simulator could be used to quickly provide system-level feedback for an optimized tuning of electronic design parameters.
NASA aviation safety reporting system
NASA Technical Reports Server (NTRS)
Billings, C. E.; Lauber, J. K.; Funkhouser, H.; Lyman, E. G.; Huff, E. M.
1976-01-01
The origins and development of the NASA Aviation Safety Reporting System (ASRS) are briefly reviewed. The results of the first quarter's activity are summarized and discussed. Examples are given of bulletins describing potential air safety hazards, and the disposition of these bulletins. During the first quarter of operation, the ASRS received 1464 reports; 1407 provided data relevant to air safety. All reports are being processed for entry into the ASRS data base. During the reporting period, 130 alert bulletins describing possible problems in the aviation system were generated and disseminated. Responses were received from FAA and others regarding 108 of the alert bulletins. Action was being taken with respect to 70 of the 108 responses received. Further studies are planned of a number of areas, including human factors problems related to automation of the ground and airborne portions of the national aviation system.
2011-01-12
including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and...Contractor Sales Data 46 Recommendations, Management Comments, and Our Response 47 Appendices A. Scope and Methodology B. Prior Audit Coverage C. DRMO...the receiving offtcial verifies the item ’s condition and ensures the quantities of items received match the DTID data . If the DTID data is
Temperature offset control system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fried, M.
1987-07-28
This patent describes a temperature offset control system for controlling the operation of both heating and air conditioning systems simultaneously contained within the same premises each of which is set by local thermostats to operate at an appropriate temperature, the offset control system comprising: a central control station having means for presetting an offset temperature range, means for sensing the temperature at a central location, means for comparing the sensed temperature with the offset temperature range, means responsive to the comparison for producing a control signal indicative of whether the sensed temperature is within the offset temperature range or beyondmore » the offset temperature range, and means for transmitting the control signal onto the standard energy lines servicing the premises; and a receiving station respectively associated with each heating and air conditioning system, the receiving stations each comprising means for receiving the same transmitted control signal from the energy lines, and switch means for controlling the energization of the respective system in response to the received control signal. The heating systems and associated local thermostat are disabled by the control signal when the control signal originates from a sensed temperature above the lower end of the offset temperature range. The air conditioning systems and associated thermostats are disabled by the same control signal when the control signal originates from a sensed temperature below the upper end of the offset temperature range.« less
Motivation in vigilance - Effects of self-evaluation and experimenter-controlled feedback.
NASA Technical Reports Server (NTRS)
Warm, J. S.; Kanfer, F. H.; Kuwada, S.; Clark, J. L.
1972-01-01
Vigilance experiments have been performed to study the relative efficiency of feedback operations in enhancing vigilance performance. Two feedback operations were compared - i.e., experimenter-controlled feedback in the form of knowledge of results (KR) regarding response times to signal detections, and subject-controlled feedback in the form of self-evaluation (SE) of response times to signal detections. The subjects responded to the aperiodic offset of a visual signal during a 1-hr vigil. Both feedback operations were found to enhance performance efficiency: subjects in the KR and SE conditions had faster response times than controls receiving no evaluative feedback. Moreover, the data of the KR and SE groups did not differ significantly from each other. The results are discussed in terms of the hypothesis that self-evaluation is a critical factor underlying the incentive value of KR in vigilance tasks.
Bagley, Stephen J; Vitale, Steven; Zhang, Suhong; Aggarwal, Charu; Evans, Tracey L; Alley, Evan W; Cohen, Roger B; Langer, Corey J; Blair, Ian A; Vachani, Anil; Whitehead, Alexander S
2017-03-01
Pemetrexed inhibits folate-dependent enzymes involved in pyrimidine and purine synthesis. Previous studies of genetic variation in these enzymes as predictors of pemetrexed efficacy have yielded inconsistent results. We investigated whether red blood cell (RBC) total folate, a phenotypic rather than genotypic, marker of cellular folate status was associated with the response to pemetrexed-based chemotherapy in advanced nonsquamous non-small-cell lung cancer (NSCLC). We conducted a prospective cohort study of patients with stage IV nonsquamous NSCLC receiving first-line chemotherapy containing pemetrexed. The pretreatment RBC total folate level was quantified using liquid chromatography mass spectrometry. We then compared the objective response rate (ORR) between patients with RBC total folate concentrations greater than and less than an optimal cutoff value determined from the receiver operating characteristic curve. A logistic regression model was used to adjust for age, sex, and the use of bevacizumab. The ORR was 62% (32 of 52 patients). Receiver operating characteristic analysis was used to establish that a RBC total folate cutoff value of 364.6 nM optimally discriminated between pemetrexed responders and nonresponders. Patients with RBC total folate < 364.5 nM had an ORR of 27% compared with 71% for patients with RBC total folate > 364.5 nM (P = .01). This difference persisted after adjusting for age, sex, and the use of bevacizumab (odds ratio, 0.07; 95% confidence interval, 0.01-0.57; P = .01). A low pretreatment RBC total folate was associated with an inferior response to pemetrexed-based chemotherapy in stage IV nonsquamous NSCLC. Larger, multicenter studies are needed to validate RBC total folate as a predictive marker of pemetrexed response. Copyright © 2016 Elsevier Inc. All rights reserved.
Dunlop, Rebecca A; Noad, Michael J; McCauley, Robert D; Scott-Hayward, Lindsay; Kniest, Eric; Slade, Robert; Paton, David; Cato, Douglas H
2017-08-15
The effect of various anthropogenic sources of noise (e.g. sonar, seismic surveys) on the behaviour of marine mammals is sometimes quantified as a dose-response relationship, where the probability of an animal behaviourally 'responding' (e.g. avoiding the source) increases with 'dose' (or received level of noise). To do this, however, requires a definition of a 'significant' response (avoidance), which can be difficult to quantify. There is also the potential that the animal 'avoids' not only the source of noise but also the vessel operating the source, complicating the relationship. The proximity of the source is an important variable to consider in the response, yet difficult to account for given that received level and proximity are highly correlated. This study used the behavioural response of humpback whales to noise from two different air gun arrays (20 and 140 cubic inch air gun array) to determine whether a dose-response relationship existed. To do this, a measure of avoidance of the source was developed, and the magnitude (rather than probability) of this response was tested against dose. The proximity to the source, and the vessel itself, was included within the one-analysis model. Humpback whales were more likely to avoid the air gun arrays (but not the controls) within 3 km of the source at levels over 140 re. 1 µPa 2 s -1 , meaning that both the proximity and the received level were important factors and the relationship between dose (received level) and response is not a simple one. © 2017. Published by The Company of Biologists Ltd.
CESA-1 receiver design review. Phase 1. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1980-07-01
The Central Electrica Solar de Almeria CESA-1 is a 1.0 MWe water/steam solar central receiver electric power plant being built by the Spanish in Almeria, Spain. Centro de Estudios de la Energia (CEE) is responsible for the management, design, and construction of the project. At the request of the Solar Energy Research Institute and with the approval of the Department of Energy, Sandia National Laboratories, Livermore is providing technical assistance in areas unique to solar applications to CEE. At the request of CEE, Sandia contracted with Foster Wheeler Development Corporation (FWDC) to critically review and evaluate the CESA-1 receiver design.more » Foster Wheeler Iberia (FWI) was subcontracted to FWDC to coordinate efforts with CEE in Madrid. The FWDC program which was started on July 9, 1979, was subdivided into three tasks: (1) design basis review: critical review of the receiver design specifications and requirements; (2) design review and analyses: critical review of thermal/hydraulic, structural, and materials aspects of the receiver design and the design and analysis procedures used by the designer in critical areas of the design; and (3) operational review: critical review of receiver instrumentation and controls and the operational and safety aspects of the receiver. Results of the design review and evaluation are presented. (WHK)« less
PPS GPS: What Is It? And How Do I Get It
1994-06-01
Positioning Service, Selective Availabilit B.PRICE CODIE 17. SECURITY CLASSIFICATION II. SECURITY CLASSIFICATION 19. SECURITY CLASSIFICATION 20...the TEC Water Detection Response Team which operates in remote areas of the world. These activities, require the GPS receiver to be capable of removing
12 CFR 917.6 - Internal control system.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Banks and Banking FEDERAL HOUSING FINANCE BOARD GOVERNANCE AND MANAGEMENT OF THE FEDERAL HOME LOAN BANKS..., including specifying the nature and frequency of reports it receives. (c) Internal control responsibilities... the major business strategies and policies established by the Bank's board of directors into operating...
Development of an Operationally-Oriented Measure of Sustainability
1991-09-01
this through new ways of using the advertising media and distribution channels. Siminlarly, process innovations also erect economies of scale and other...profound effect on structure include sweeping regulations on entry into the industry, competitive practices, and profit structure. Policies that govern... advertised , Cramer received over 55,000 responses. A decision was made to follow up each response with a field visit; however, the sales force was not
2017-06-06
OMB No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for...Geophysical Mapping, Electromagnetic Induction, Instrument Verification Strip, Time Domain Electromagnetic, Unexploded Ordnance 16. SECURITY...Munitions Response QA Quality Assurance QC Quality Control ROC Receiver Operating Characteristic RTK Real- time Kinematic s Second SNR
2016-01-01
carpentry, masonry , and the operation of heavy equipment. Plans called for the NEB to receive at least $29 million in engineering equipment and...JTF Sapper, NMCB 25, and NMCB 28, had responsibility for training the NEB in such areas as plumbing, electrical work, carpentry, masonry , and...measurement tool consisted of five possible ratings: fully capable, capable, partially capable, developing, and established. USFOR-A used these
Wang, W; Zhai, Y; Zhang, Z H; Li, Y; Zhang, Z Y
2016-11-08
Objective: To investigate the clinical efficacy, safety and promotion value of TB type thermal balloon endometrial ablation in the treatment of abnormal uterine bleeding. Methods: Fourty three patients who had received TB type endometrial ablation system for treatment of abnormal uterine bleeding from January, 2015 to January, 2016 in theDepartment of gynecology, Beijing Chaoyang Hospital were enrolled in this study. The intra-operative and post-operative complications and improvement of abnormal uterine bleeding and dysmenorrhea were observed. Results: There were nointra-operative complication occurred, such as uterine perforation, massive hemorrhage or surrounding organ damage. At 6 months after operation, 32 patients developed amenorrhea, 6 developed menstrual spotting, 3 developed menstruation with a small volume and 1 had a normal menstruation. No menstruation with an increased volume occurred. The occurrence of amenorrhea was 76.19% and the response rate was 97.62%.At 6 months after operation, 1 case had no response, 2 cases had partial response and 11 cases had complete response among the 14 cases of pre-operative dysmenorrhea; only 3 cases still had anemia among the 23 cases of pre-operative anemia. Compared with before treatment, patients with dysmenorrhea and anemia both significantly reduced with a statistically significant difference( P <0.01). Conclusion: TB type thermal balloon endometrial ablation has a significant efficacy with high safety for the treatment of abnormal uterine bleeding, which could have clinical promotion practice.
Behavioral responses of humpback whales (Megaptera novaeangliae) to full-scale ATOC signals.
Frankel, A S; Clark, C W
2000-10-01
Loud (195 dB re 1 microPa at 1 m) 75-Hz signals were broadcast with an ATOC projector to measure ocean temperature. Respiratory and movement behaviors of humpback whales off North Kauai, Hawaii, were examined for potential changes in response to these transmissions and to vessels. Few vessel effects were observed, but there were fewer vessels operating during this study than in previous years. No overt responses to ATOC were observed for received levels of 98-109 dB re 1 microPa. An analysis of covariance, using the no-sound behavioral rate as a covariate to control for interpod variation, found that the distance and time between successive surfacings of humpbacks increased slightly with an increase in estimated received ATOC sound level. These responses are very similar to those observed in response to scaled-amplitude playbacks of ATOC signals [Frankel and Clark, Can. J. Zool. 76, 521-535 (1998)]. These similar results were obtained with different sound projectors, in different years and locations, and at different ranges creating a different sound field. The repeatability of the findings for these two different studies indicates that these effects, while small, are robust. This suggests that at least for the ATOC signal, the received sound level is a good predictor of response.
Whispering-gallery-mode-based seismometer
Fourguette, Dominique Claire; Otugen, M Volkan; Larocque, Liane Marie; Ritter, Greg Aan; Meeusen, Jason Jeffrey; Ioppolo, Tindaro
2014-06-03
A whispering-gallery-mode-based seismometer provides for receiving laser light into an optical fiber, operatively coupling the laser light from the optical fiber into a whispering-gallery-mode-based optical resonator, operatively coupling a spring of a spring-mass assembly to a housing structure; and locating the whispering-gallery-mode-based optical resonator between the spring-mass assembly and the housing structure so as to provide for compressing the whispering-gallery-mode-based optical resonator between the spring-mass assembly and the housing structure responsive to a dynamic compression force from the spring-mass assembly responsive to a motion of the housing structure relative to an inertial frame of reference.
Schneider, H
2018-05-16
In all phases, patients are entitled to receive medical treatment according to medical specialist standards. This does not mean that patients necessarily have to be treated by a medical specialist. Operations performed by "beginners", e. g. assistant physicians, are permitted. However, there are increased liability risks, both for the specialist and the assistant physician. Furthermore, there are risks of criminal responsibility for causing bodily harm by negligence or negligent manslaughter. This article portrays the requirements of civil liability and criminal responsibility concerning beginners' operations on the basis of cases and judgments of the Federal Court and the Higher Regional Courts in Germany. Additionally, the reception of the jurisprudence by the relevant legal literature will be discussed. Jurisprudence and legal literature categorize breaches of duty of care. Assistant physicians can be subject to contributory negligence liabilities, while specialists can bear liabilities for negligent selection, organization or supervision. Responsible specialist and assistant physicians can protect themselves (and the patient) and avoid legal risks by only performing operations adequate to their educational level or by delegating operations to beginners and ensuring intervention by a specialist by supervision of the operation which is suitable to the assistant physician's level of education.
Kim, Young K; Lee, Scott S; Suh, Euy H; Lee, Lyon; Lee, Hee C; Lee, Hyo J; Yeon, Seong C
2012-02-01
This study investigated the use of sprayed intraperitoneal bupivacaine to relieve postoperative pain behavior and biochemical stress response after laparoscopic ovariohysterectomy (LOVH) in dogs. Sixteen sexually intact female dogs were randomly assigned to two groups. The sprayed intraperitoneal bupivacaine (SIB) group received 4.4 mg/kg of sprayed intraperitoneal bupivacaine diluted to 0.25% with an equivalent volume of saline after pneumoperitoneum. The control group received 1.76 mL/kg of saline in a similar fashion. Both groups received preoperative periportal 5% bupivacaine (1 mL) before incision. Postoperative pain was measured using the short form of the Glasgow composite measures pain scale (CMPS-SF, 0-24). Serum cortisol and glucose concentrations were measured preoperatively and 0.5, 1, 2, 4, 6, 12, and 24h postoperatively. The SIB group had significantly lower CMPS-SF compared to the control group 1, 2, 4, 6, and 12h after the operation. Cortisol concentrations were significantly increased from preoperative concentrations in the control group at 0.5, 1, 2, and 4h post operation and at 0.5 and 1h post operation in the SIB group. No significant differences were seen in serum glucose within each group. This report suggests that the use of sprayed intraperitoneal bupivacaine can be used as part of a multimodal approach for pain management after LOVH in dogs. Copyright © 2011 Elsevier Ltd. All rights reserved.
The D-Region Ionospheric Response to the 2017 Solar Eclipse
NASA Astrophysics Data System (ADS)
Cohen, M.; McCormick, J.; Gross, N. C.; Higginson-Rollins, M. A.
2017-12-01
VLF/LF radio remote sensing (0.5-500 kHz) is an effective means for quantifying the D-region ionosphere (60-90 km altitude). Disturbances in the ionospheric electron density induce changes in the propagation of VLF/LF signals, so a network of transmitters and receivers can effectively "image" a disturbed region. VLF/LF signals can all be detected from 100s-1000s of km away. We utilize Georgia Tech's network of highly-sensitive VLF/LF receivers to quantify the lower ionospheric response to the "Great American Eclipse". Nine of these were deployed and operational across the Continental US, Alaska and Puerto Rico all operated successfully. Each receiver synchronously recorded the full radio spectrum between 0.5-470 kHz. The included figure shows the eclipse track at 80 km altitude with a green swath. The nine operational receivers are shown with blue stars, and operational VLF/LF transmitters in dark red. Gray lines are shown for each great-circle path linking a VLF/LF transmitter to a receiver. This constellation forms a dense spider's-web grid of radio links, with which we can effectively image the disturbed patch of the D-region ionosphere as it moves across the country. In addition, shown in yellow are NDGPS transmitters which lie between 285-325 kHz. The red dots are the 230,000 geolocated lightning strokes during the 90-mintue eclipse pass, each of which emitted an intense VLF/LF impulse. These are also detected by our receivers. We present our observations and comparison with a theoretical model, using a combination of three techniques established by a series of three 2017 journal papers: (1) Polarization measurements of VLF/LF transmitter signals, (2) Lightning-generated VLF sferics detected 1000s of km away, and (3) NDGPS beacons near 300 kHz for shorter-range sounding of a small patch of the ionosphere. We find evidence of large scale ionospheric changes which affect the D-region over the entire continental region with a slowly-varying signal perturbation. At some sites close to the totality zone, however, we have evidence of forward scattering from the shadow of the moon, which effectively is a patch of nighttime surrounded by daytime, that can only be observed in a narrower region around the totality zone. Implications of these results for D-region ionospheric dynamics are discussed.
Grilo, C. M.; White, M. A.; Wilson, G. T.; Gueorguieva, R.; Masheb, R. M.
2011-01-01
Background We examined rapid response in obese patients with binge-eating disorder (BED) in a clinical trial testing cognitive behavioral therapy (CBT) and behavioral weight loss (BWL). Method Altogether, 90 participants were randomly assigned to CBT or BWL. Assessments were performed at baseline, throughout and post-treatment and at 6- and 12-month follow-ups. Rapid response, defined as ≥70% reduction in binge eating by week four, was determined by receiver operating characteristic curves and used to predict outcomes. Results Rapid response characterized 57% of participants (67% of CBT, 47% of BWL) and was unrelated to most baseline variables. Rapid response predicted greater improvements across outcomes but had different prognostic significance and distinct time courses for CBT versus BWL. Patients receiving CBT did comparably well regardless of rapid response in terms of reduced binge eating and eating disorder psychopathology but did not achieve weight loss. Among patients receiving BWL, those without rapid response failed to improve further. However, those with rapid response were significantly more likely to achieve binge-eating remission (62% v. 13%) and greater reductions in binge-eating frequency, eating disorder psychopathology and weight loss. Conclusions Rapid response to treatment in BED has prognostic significance through 12-month follow-up, provides evidence for treatment specificity and has clinical implications for stepped-care treatment models for BED. Rapid responders who receive BWL benefit in terms of both binge eating and short-term weight loss. Collectively, these findings suggest that BWL might be a candidate for initial intervention in stepped-care models with an evaluation of progress after 1 month to identify non-rapid responders who could be advised to consider a switch to a specialized treatment. PMID:21923964
78 FR 17391 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-21
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 Take notice that the Commission received the following electric rate filings: Docket Numbers: ER109-1997-000; ER10-1997-001. Applicants: Midwest Independent Transmission System Operator, Inc. Description: Informational Response of The Midwest Independent...
40 CFR 240.211-3 - Recommended procedures: Operations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... measurements and laboratory analyses required by the responsible agency. (12) Complete records of monitoring... waste received and processed, summarized on a monthly basis. (2) A summary of the laboratory analyses including at least monthly averages. (3) Number and qualifications of personnel in each job category; total...
45 CFR 303.7 - Provision of services in interstate IV-D cases.
Code of Federal Regulations, 2010 CFR
2010-10-01
... ENFORCEMENT (CHILD SUPPORT ENFORCEMENT PROGRAM), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES STANDARDS FOR PROGRAM OPERATIONS § 303.7 Provision of services in interstate IV... central registry responsible for receiving, distributing and responding to inquiries on all incoming...
Sources of Financing for Community Colleges.
ERIC Educational Resources Information Center
Graham, Steve; Anderson, Duane
1985-01-01
Reports on a nationwide survey of community college funding sources to determine the level of overall college budgets, the percentages of funds received from various sources for operating and capital expenses, the funding role of college foundations, administrator responsibilities, and fund-raising methods used by two-year colleges. (DMM)
A memory-mapped output interface: Omega navigation output data from the JOLT (TM) microcomputer
NASA Technical Reports Server (NTRS)
Lilley, R. W.
1976-01-01
A hardware interface which allows both digital and analog data output from the JOLT microcomputer is described in the context of a software-based Omega Navigation receiver. The interface hardware described is designed for output of six (or eight with simple extensions) bits of binary output in response to a memory store command from the microcomputer. The interface was produced in breadboard form and is operational as an evaluation aid for the software Omega receiver.
NASA Astrophysics Data System (ADS)
Chen, Zhengwei; Wang, Yueshe; Hao, Yun; Wang, Qizhi
2013-07-01
The solar cavity receiver is an important light-energy to thermal-energy convector in the tower solar thermal power plant system. The heat flux in the inner surface of the cavity will show the characteristics of non-continuous step change especially in non-normal and transient weather conditions, which may result in a continuous dynamic variation of the characteristic parameters. Therefore, the research of dynamic characteristics of the receiver plays a very important role in the operation and the control safely in solar cavity receiver system. In this paper, based on the non-continuous step change of radiation flux, a non-linear dynamic model is put forward to obtain the effects of the non-continuous step change radiation flux and step change feed water flow on the receiver performance by sequential modular approach. The subject investigated in our study is a 1MW solar power station constructed in Yanqing County, Beijing. This study has obtained the dynamic responses of the characteristic parameters in the cavity receiver, such as drum pressure, drum water level, main steam flow and main steam enthalpy under step change radiation flux. And the influence law of step-change feed water flow to the dynamic characteristics in the receiver also has been analyzed. The results have a reference value for the safe operation and the control in solar cavity receiver system.
Influence of preoperative oral feeding on stress response after resection for colon cancer.
Zelić, Marko; Stimac, Davor; Mendrila, Davor; Tokmadžić, Vlatka Sotošek; Fišić, Elizabeta; Uravić, Miljenko; Sustić, Alan
2012-01-01
Preoperative management involves patients fasting from midnight on the evening prior to surgery. Fasting period is often long enough to change the metabolic condition of the patient which increases perioperative stress response. That could have a detrimental effect on clinical outcome. The aim of the present study was to investigate the possible effects of carbohydrate-rich beverage on stress response after colon resection. Randomized and double blinded study included 40 patients with colon, upper rectal or rectosigmoid cancer. Investigated group received a carbohydrate-rich beverage the day before and two hours before surgery. In the control group patients were in the standard preoperative regime: nothing by mouth from the evening prior to operation. Peripheral blood was sampled 24h before surgery, at the day of the surgery, and 6, 24 and 48h postoperatively. Colonic resection in both groups caused a significant increase in serum interleukin 6 (IL-6) levels 6, 24 and 48h after the operation. Increase was more evident and statistically significant in the group with fasting protocol. More significant increase of interleukin 10 (IL-10) occurred in patients who received preoperative nutrition. Smaller increase in IL-6 and higher in IL- 10 are indicators of reduced perioperative stress.
Lúcia, Marc; Crespo, Elena; Melilli, Edoardo; Cruzado, Josep M.; Luque, Sergi; Llaudó, Inés; Niubó, Jordi; Torras, Joan; Fernandez, Núria; Grinyó, Josep M.; Bestard, Oriol
2014-01-01
Background. Cytomegalovirus (CMV) infection remains a major complication after kidney transplantation. Baseline CMV risk is typically determined by the serological presence of preformed CMV-specific immunoglobulin (Ig) G antibodies, even though T-cell responses to major viral antigens are crucial when controlling viral replication. Some IgG-seronegative patients who receive an IgG-seropositive allograft do not develop CMV infection despite not receiving prophylaxis. We hypothesized that a more precise evaluation of pretransplant CMV-specific immune-sensitization using the B and T-cell enzyme-linked immunospot assays may identify CMV-sensitized individuals more accurately, regardless of serological evidence of CMV-specific IgG titers. Methods. We compared the presence of preformed CMV-specific memory B and T cells in kidney transplant recipients between 43 CMV IgG–seronegative (sR−) and 86 CMV IgG–seropositive (sR+) patients. Clinical outcome was evaluated in both groups. Results. All sR+ patients showed a wide range of CMV-specific memory T- and B-cell responses. High memory T- and B-cell frequencies were also clearly detected in 30% of sR− patients, and those with high CMV-specific T-cell frequencies had a significantly lower incidence of late CMV infection after prophylactic therapy. Receiver operating characteristic curve analysis for predicting CMV viremia and disease showed a high area under the receiver operating characteristic curve (>0.8), which translated into a high sensitivity and negative predictive value of the test. Conclusions. Assessment of CMV-specific memory T- and B-cell responses before kidney transplantation among sR− recipients may help identify immunized individuals more precisely, being ultimately at lower risk for CMV infection. PMID:25048845
A review of automatic mass detection and segmentation in mammographic images.
Oliver, Arnau; Freixenet, Jordi; Martí, Joan; Pérez, Elsa; Pont, Josep; Denton, Erika R E; Zwiggelaar, Reyer
2010-04-01
The aim of this paper is to review existing approaches to the automatic detection and segmentation of masses in mammographic images, highlighting the key-points and main differences between the used strategies. The key objective is to point out the advantages and disadvantages of the various approaches. In contrast with other reviews which only describe and compare different approaches qualitatively, this review also provides a quantitative comparison. The performance of seven mass detection methods is compared using two different mammographic databases: a public digitised database and a local full-field digital database. The results are given in terms of Receiver Operating Characteristic (ROC) and Free-response Receiver Operating Characteristic (FROC) analysis. Copyright 2009 Elsevier B.V. All rights reserved.
Tilburt, Jon C; Koller, Kathryn; Tiesinga, James J; Wilson, Robin T; Trinh, Anne C; Hill, Kristin; Hall, Ingrid J; Smith, Judith Lee; Ekwueme, Donatus U; Petersen, Wesley O
2013-11-01
To assess clinical treatment patterns and response times among American Indian/Alaska Native men with a newly elevated PSA. We retrospectively identified men ages 50-80 receiving care in one of three tribally-operated clinics in Northern Minnesota, one medical center in Alaska, and who had an incident PSA elevation (> 4 ng/ml) in a specified time period. A clinical response was considered timely if it was documented as occurring within 90 days of the incident PSA elevation. Among 82 AI/AN men identified from medical records with an incident PSA elevation, 49 (60%) received a timely clinical response, while 18 (22%) had no documented clinical response. One in five AI/AN men in our study had no documented clinical action following an incident PSA elevation. Although a pilot study, these findings suggest the need to improve the documentation, notification, and care following an elevated PSA at clinics serving AI/AN men.
A simple prediction tool for inhaled corticosteroid response in asthmatic children.
Wu, Yi-Fan; Su, Ming-Wei; Chiang, Bor-Luen; Yang, Yao-Hsu; Tsai, Ching-Hui; Lee, Yungling L
2017-12-07
Inhaled corticosteroids are recommended as the first-line controller medication for childhood asthma owing to their multiple clinical benefits. However, heterogeneity in the response towards these drugs remains a significant clinical problem. Children aged 5 to 18 years with mild to moderate persistent asthma were recruited into the Taiwanese Consortium of Childhood Asthma Study. Their responses to inhaled corticosteroids were assessed based on their improvements in the asthma control test and peak expiratory flow. The predictors of responsiveness were demographic and clinical features that were available in primary care settings. We have developed a prediction model using logistic regression and have simplified it to formulate a practical tool. We assessed its predictive performance using the area under the receiver operating characteristic curve. Of the 73 asthmatic children with baseline and follow-up outcome measurements for inhaled corticosteroids treatment, 24 (33%) were defined as non-responders. The tool we have developed consisted of three predictors yielding a total score between 0 and 5, which are comprised of the following parameters: the age at physician-diagnosis of asthma, sex, and exhaled nitric oxide. Sensitivity and specificity of the tool for prediction of inhaled corticosteroids non-responsiveness, for a score of 3, were 0.75 and 0.69, respectively. The areas under the receiver operating characteristic curve for the prediction tool was 0.763. Our prediction tool represents a simple and low-cost method for predicting the response of inhaled corticosteroids treatment in asthmatic children.
Ground test program for a full-size solar dynamic heat receiver
NASA Technical Reports Server (NTRS)
Sedgwick, L. M.; Kaufmann, K. J.; Mclallin, K. L.; Kerslake, T. W.
1991-01-01
Test hardware, facilities, and procedures were developed to conduct ground testing of a full-size, solar dynamic heat receiver in a partially simulated, low earth orbit environment. The heat receiver was designed to supply 102 kW of thermal energy to a helium and xenon gas mixture continuously over a 94 minute orbit, including up to 36 minutes of eclipse. The purpose of the test program was to quantify the receiver thermodynamic performance, its operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber using liquid nitrogen cold shrouds and an aperture cold plate. Special test equipment was designed to provide the required ranges in interface boundary conditions that typify those expected or required for operation as part of the solar dynamic power module on the Space Station Freedom. The support hardware includes an infrared quartz lamp heater with 30 independently controllable zones and a closed-Brayton cycle engine simulator to circulate and condition the helium-xenon gas mixture. The test article, test support hardware, facilities, and instrumentation developed to conduct the ground test program are all described.
Ground test program for a full-size solar dynamic heat receiver
NASA Technical Reports Server (NTRS)
Sedgwick, L. M.; Kaufmann, K. J.; Mclallin, K. L.; Kerslake, T. W.
1991-01-01
Test hardware, facilities, and procedures were developed to conduct ground testing of a full size, solar dynamic heat receiver in a partially simulated, low Earth orbit environment. The heat receiver was designed to supply 102 kW of thermal energy to a helium and xenon gas mixture continuously over a 94 minute orbit, including up to 36 minutes of eclipse. The purpose of the test program was to quantify the receiver thermodynamic performance, its operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber using liquid nitrogen cold shrouds and an aperture cold plate. Special test equipment were designed to provide the required ranges in interface boundary conditions that typify those expected or required for operation as part of the solar dynamic power module on the Space Station Freedom. The support hardware includes an infrared quartz lamp heater with 30 independently controllable zones and a closed Brayton cycle engine simulator to circulate and condition the helium xenon gas mixture. The test article, test support hardware, facilities, and instrumentation developed to conduct the ground test program are all described.
Ground test program for a full-size solar dynamic heat receiver
NASA Astrophysics Data System (ADS)
Sedgwick, L. M.; Kaufmann, K. J.; McLallin, K. L.; Kerslake, T. W.
Test hardware, facilities, and procedures were developed to conduct ground testing of a full-size, solar dynamic heat receiver in a partially simulated, low earth orbit environment. The heat receiver was designed to supply 102 kW of thermal energy to a helium and xenon gas mixture continuously over a 94 minute orbit, including up to 36 minutes of eclipse. The purpose of the test program was to quantify the receiver thermodynamic performance, its operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber using liquid nitrogen cold shrouds and an aperture cold plate. Special test equipment was designed to provide the required ranges in interface boundary conditions that typify those expected or required for operation as part of the solar dynamic power module on the Space Station Freedom. The support hardware includes an infrared quartz lamp heater with 30 independently controllable zones and a closed-Brayton cycle engine simulator to circulate and condition the helium-xenon gas mixture. The test article, test support hardware, facilities, and instrumentation developed to conduct the ground test program are all described.
The positive impact of structured teaching in the operating room.
Leung, Yee; Salfinger, Stuart; Mercer, Annette
2015-12-01
A survey of obstetric and gynaecology trainees in Australia found the trainee's opinion of the consultants' teaching ability for laparoscopic procedures and procedures dealing with complications as 'poor' in 21.2% and 23.4% of responses, respectively (Aust NZ J Obstet Gynaecol 2009; 49: 84). Surgical caseload per trainee is falling for a variety of reasons. Strategies need to be adopted to enhance the surgical learning experience of trainees in the operating room. We describe the use of a structured encounter template to facilitate the teaching of surgery in the operating room and report the response of the trainees to this intervention. Trainees attached to a gynaecologic surgery unit all underwent surgical training using a set format based on the surgical encounter template, including briefing, goal setting and intra-operative teaching aims as well as debriefing. Data on the trainees' experience and perception of their learning experience were then collected and analysed as quantitative and qualitative data sets. The trainees reported satisfaction with the use of a structured encounter template to facilitate the surgical teaching in the operating room. Some trainees had not received such clarity of feedback or the opportunity to complete a procedure independently prior to using the structured encounter template. A structured surgical encounter template based on andragogy principles to focus consultant teaching in the operating room is highly acceptable to obstetric and gynaecology trainees in Australia. Allowing the trainee the opportunity to set objectives and receive feedback empowers the trainee and enhances their educational experience. © 2015 The Royal Australian and New Zealand College of Obstetricians and Gynaecologists.
An Operations Manual for Achieving Nitrification in an Activated Sludge Plant.
ERIC Educational Resources Information Center
Ontario Ministry of the Environment, Toronto.
In Ontario, the attainment of nitrification (oxidation of ammonia) in activated sludge plants is receiving increased attention. Nitrification of waste water is a necessary requirement because it reduces plant discharge of nitrogenous oxygen demand and/or toxic ammonia. However, this new requirement will result in added responsibility for…
Stationary Engineering Laboratory Manual--2.
ERIC Educational Resources Information Center
Steingress, Frederick M.; Frost, Harold J.
The Stationary Engineering Laboratory Manual 2 was designed for vocational/technical high school students who have received instruction in the basics of stationary engineering. It was developed for students who will be operating a live plant and who will be responsible for supplying steam for heating, cooking, and baking. Each lesson in the manual…
Prevalence and Correlates of Autism in a State Psychiatric Hospital
ERIC Educational Resources Information Center
Mandell, David S.; Lawer, Lindsay J.; Branch, Kira; Brodkin, Edward S.; Healey, Kristin; Witalec, Robert; Johnson, Donielle N.; Gur, Raquel E.
2012-01-01
This study estimated the ASD prevalence in a psychiatric hospital and evaluated the Social Responsiveness Scale (SRS) combined with other information for differential diagnosis. Chart review, SRS and clinical interviews were collected for 141 patients at one hospital. Diagnosis was determined at case conference. Receiver operating characteristic…
Recognition Memory: Adding a Response Deadline Eliminates Recollection but Spares Familiarity
ERIC Educational Resources Information Center
Sauvage, Magdalena M.; Beer, Zachery; Eichenbaum, Howard
2010-01-01
A current controversy in memory research concerns whether recognition is supported by distinct processes of familiarity and recollection, or instead by a single process wherein familiarity and recollection reflect weak and strong memories, respectively. Recent studies using receiver operating characteristic (ROC) analyses in an animal model have…
42 CFR 476.78 - Responsibilities of health care facilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
... furnished to Medicare beneficiaries must maintain a written agreement with a QIO operating in the area in... information within 30 days of a request. QIOs pay providers paid under the prospective payment system for the... receive retrospective prepayment review, according to the review priority established by the QIO. (c...
Adaptive reconfigurable V-BLAST type equalizer for cognitive MIMO-OFDM radios
NASA Astrophysics Data System (ADS)
Ozden, Mehmet Tahir
2015-12-01
An adaptive channel shortening equalizer design for multiple input multiple output-orthogonal frequency division multiplexing (MIMO-OFDM) radio receivers is considered in this presentation. The proposed receiver has desirable features for cognitive and software defined radio implementations. It consists of two sections: MIMO decision feedback equalizer (MIMO-DFE) and adaptive multiple Viterbi detection. In MIMO-DFE section, a complete modified Gram-Schmidt orthogonalization of multichannel input data is accomplished using sequential processing multichannel Givens lattice stages, so that a Vertical Bell Laboratories Layered Space Time (V-BLAST) type MIMO-DFE is realized at the front-end section of the channel shortening equalizer. Matrix operations, a major bottleneck for receiver operations, are accordingly avoided, and only scalar operations are used. A highly modular and regular radio receiver architecture that has a suitable structure for digital signal processing (DSP) chip and field programable gate array (FPGA) implementations, which are important for software defined radio realizations, is achieved. The MIMO-DFE section of the proposed receiver can also be reconfigured for spectrum sensing and positioning functions, which are important tasks for cognitive radio applications. In connection with adaptive multiple Viterbi detection section, a systolic array implementation for each channel is performed so that a receiver architecture with high computational concurrency is attained. The total computational complexity is given in terms of equalizer and desired response filter lengths, alphabet size, and number of antennas. The performance of the proposed receiver is presented for two-channel case by means of mean squared error (MSE) and probability of error evaluations, which are conducted for time-invariant and time-variant channel conditions, orthogonal and nonorthogonal transmissions, and two different modulation schemes.
Low-energy neutron detector based upon lithium lanthanide borate scintillators
Czirr, John B.
1998-01-01
An apparatus for detecting neutrons includes a cerium activated scintillation crystal containing .sup.10 B, with the scintillation crystal emitting light in response to .alpha. particles emitted from the .sup.10 B(n,.alpha.)Li* reaction. The apparatus also includes a gamma scintillator positioned adjacent the crystal and which generates light in response to gamma rays emitted from the decay of Li*. The apparatus further includes a first and a second light-to-electronic signal converter each positioned to respectively receive light from the crystal and the gamma scintillator, and each respectively outputting first and second electronic signals representative of .alpha. particles from the .sup.10 B(n,.alpha.)Li* reaction and gamma rays from the .sup.10 B(n,.alpha.)Li* reaction. The apparatus includes a coincidence circuit connected to receive the first and second signals and which generates a coincidence signal when the first and second signals coincide. The apparatus also includes a data analyzer for receiving an additional signal from at least one of the first and second converters, and for operating in response to the coincidence signal.
Early hepatitis B viral DNA clearance predicts treatment response at week 96
Fu, Xiao-Yu; Tan, De-Ming; Liu, Cui-Mei; Gu, Bin; Hu, Li-Hua; Peng, Zhong-Tian; Chen, Bin; Xie, Yuan-Lin; Gong, Huan-Yu; Hu, Xiao-Xuan; Yao, Lian-Hui; Xu, Xiao-Ping; Fu, Zheng-Yuan; He, Lang-Qiu; Li, Si-Hai; Long, Yun-Zhu; Li, De-Hui; Gu, Ji-Long; Peng, Shi-Fang
2017-01-01
AIM To investigate whether hepatitis viral DNA load at 24 wk of treatment predicts response at 96 wk in patients with chronic hepatitis B. METHODS A total of 172 hepatitis B envelope antigen (HBeAg)-positive chronic hepatitis B patients who received initial treatment at 16 tertiary hospitals in Hunan Province, China were enrolled in this study. All patients received conventional doses of lamivudine and adefovir dipivoxil, telbivudine, entecavir dispersible tablets, or entecavir tablets for 96 wk. Patients who used other antiviral drugs or antitumor and immune regulation therapy were excluded. Patients were stratified into three groups according to their viral DNA load at 24 wk: < 10 IU/mL (group 1), 10-103 IU/mL (group 2), and > 103 IU/mL (group 3). Correlations of 24-wk DNA load with HBeAg negative status and HBeAg seroconversion at 96 wk were analyzed. Receiver operating characteristic curve analysis was used to test the predictive value of the HBV DNA load at 24 wk for long-term response. RESULTS The rates of conversion to HBeAg negative status and HBeAg seroconversion rates were 53.7% and 51.9%, respectively, in group 1; 35.21% and 32.39% in group 2; and 6.38% and 6.38% in group 3. The receiver operating characteristic curves for the three subgroups revealed that the lowest DNA load (< 10 IU/mL) was better correlated with response at 96 wk than a higher DNA load (10-103 IU/mL). Nested PCR was used for amplifying and sequencing viral DNA in patients with a viral DNA load > 200 IU/mL at 96 wk; resistance mutations involving different loci were present in 26 patients, and three of these patients had a viral DNA load 10-103 IU/mL at 96 wk. CONCLUSION Hepatitis B viral DNA load at 24 wk of antiviral treatment in patients with chronic hepatitis B is a predictor of the viral load and response rate at 96 wk. PMID:28522916
Team Electronic Gameplay Combining Different Means of Control
NASA Technical Reports Server (NTRS)
Palsson, Olafur S. (Inventor); Pope, Alan T. (Inventor)
2014-01-01
Disclosed are methods and apparatuses provided for modifying the effect of an operator controlled input device on an interactive device to encourage the self-regulation of at least one physiological activity by a person different than the operator. The interactive device comprises a display area which depicts images and apparatus for receiving at least one input from the operator controlled input device to thus permit the operator to control and interact with at least some of the depicted images. One effect modification comprises measurement of the physiological activity of a person different from the operator, while modifying the ability of the operator to control and interact with at least some of the depicted images by modifying the input from the operator controlled input device in response to changes in the measured physiological signal.
Aggregate Load Controllers and Associated Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chassin, David P.
Aggregate load controllers and associated methods are described. According to one aspect, a method of operating an aggregate load controller includes using an aggregate load controller having an initial state, applying a stimulus to a plurality of thermostatic controllers which are configured to control a plurality of respective thermostatic loads which receive electrical energy from an electrical utility to operate in a plurality of different operational modes, accessing data regarding a response of the thermostatic loads as a result of the applied stimulus, using the data regarding the response, determining a value of at least one design parameter of themore » aggregate load controller, and using the determined value of the at least one design parameter, configuring the aggregate load controller to control amounts of the electrical energy which are utilized by the thermostatic loads.« less
Voluntary modulation of anterior cingulate response to negative feedback.
Shane, Matthew S; Weywadt, Christina R
2014-01-01
Anterior cingulate and medial frontal cortex (dACC/mFC) response to negative feedback represents the actions of a generalized error-monitoring system critical for the management of goal-directed behavior. Magnitude of dACC/mFC response to negative feedback correlates with levels of post-feedback behavioral change, and with proficiency of operant learning processes. With this in mind, it follows that an ability to alter dACC/mFC response to negative feedback may lead to representative changes in operant learning proficiency. To this end, the present study investigated the extent to which healthy individuals would show modulation of their dACC/mFC response when instructed to try to either maximize or minimize their neural response to the presentation of contingent negative feedback. Participants performed multiple runs of a standard time-estimation task, during which they received feedback regarding their ability to accurately estimate a one-second duration. On Watch runs, participants were simply instructed to try to estimate as closely as possible the one second duration. On Increase and Decrease runs, participants performed the same task, but were instructed to "try to increase [decrease] their brain's response every time they received negative feedback". Results indicated that participants showed changes in dACC/mFC response under these differing instructional conditions: dACC/mFC activity following negative feedback was higher in the Increase condition, and dACC activity trended lower in the Decrease condition, compared to the Watch condition. Moreover, dACC activity correlated with post-feedback performance adjustments, and these adjustments were highest in the Increase condition. Potential implications for neuromodulation and facilitated learning are discussed.
The Spacecraft Emergency Response System (SERS) for Autonomous Mission Operations
NASA Technical Reports Server (NTRS)
Breed, Julia; Chu, Kai-Dee; Baker, Paul; Starr, Cynthia; Fox, Jeffrey; Baitinger, Mick
1998-01-01
Today, most mission operations are geared toward lowering cost through unmanned operations. 7-day/24-hour operations are reduced to either 5-day/8-hour operations or become totally autonomous, especially for deep-space missions. Proper and effective notification during a spacecraft emergency could mean success or failure for an entire mission. The Spacecraft Emergency Response System (SERS) is a tool designed for autonomous mission operations. The SERS automatically contacts on-call personnel as needed when crises occur, either on-board the spacecraft or within the automated ground systems. Plus, the SERS provides a group-ware solution to facilitate the work of the person(s) contacted. The SERS is independent of the spacecraft's automated ground system. It receives and catalogues reports for various ground system components in near real-time. Then, based on easily configurable parameters, the SERS determines whom, if anyone, should be alerted. Alerts may be issued via Sky-Tel 2-way pager, Telehony, or e-mail. The alerted personnel can then review and respond to the spacecraft anomalies through the Netscape Internet Web Browser, or directly review and respond from the Sky-Tel 2-way pager.
40 CFR 96.110 - Authorization and responsibilities of CAIR designated representative.
Code of Federal Regulations, 2012 CFR
2012-07-01
...)(4)(iv). (c) Upon receipt by the Administrator of a complete certificate of representation under § 96... representations, actions, inactions, or submissions, legally bind each owner and operator of the CAIR NOX source... received a complete certificate of representation under § 96.113 for a CAIR designated representative of...
40 CFR 96.110 - Authorization and responsibilities of CAIR designated representative.
Code of Federal Regulations, 2010 CFR
2010-07-01
...)(4)(iv). (c) Upon receipt by the Administrator of a complete certificate of representation under § 96... representations, actions, inactions, or submissions, legally bind each owner and operator of the CAIR NOX source... received a complete certificate of representation under § 96.113 for a CAIR designated representative of...
40 CFR 96.110 - Authorization and responsibilities of CAIR designated representative.
Code of Federal Regulations, 2014 CFR
2014-07-01
...)(4)(iv). (c) Upon receipt by the Administrator of a complete certificate of representation under § 96... representations, actions, inactions, or submissions, legally bind each owner and operator of the CAIR NOX source... received a complete certificate of representation under § 96.113 for a CAIR designated representative of...
40 CFR 96.110 - Authorization and responsibilities of CAIR designated representative.
Code of Federal Regulations, 2011 CFR
2011-07-01
...)(4)(iv). (c) Upon receipt by the Administrator of a complete certificate of representation under § 96... representations, actions, inactions, or submissions, legally bind each owner and operator of the CAIR NOX source... received a complete certificate of representation under § 96.113 for a CAIR designated representative of...
40 CFR 96.110 - Authorization and responsibilities of CAIR designated representative.
Code of Federal Regulations, 2013 CFR
2013-07-01
...)(4)(iv). (c) Upon receipt by the Administrator of a complete certificate of representation under § 96... representations, actions, inactions, or submissions, legally bind each owner and operator of the CAIR NOX source... received a complete certificate of representation under § 96.113 for a CAIR designated representative of...
Feasibility Study Concerning the Use of Volunteers at Germanna Community College.
ERIC Educational Resources Information Center
Germanna Community Coll., Locust Grove, VA.
In 1990, a feasibility study was conducted to determine the usefulness of volunteers in the day-to-day operations of Germanna Community College. A questionnaire was distributed to 18 administrative and support staff personnel; 17 responses were received. Questions focused on respondents' opinions of the need for volunteers, type of assistance…
45 CFR 98.30 - Parental choice.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Program Operations (Child Care Services)-Parental Rights and Responsibilities § 98.30 Parental choice. (a) The parent or parents of an eligible child who receives or is offered child care services shall be... available to a parent. (b) When a parent elects to enroll the child with a provider that has a grant or...
45 CFR 98.30 - Parental choice.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Program Operations (Child Care Services)-Parental Rights and Responsibilities § 98.30 Parental choice. (a) The parent or parents of an eligible child who receives or is offered child care services shall be... available to a parent. (b) When a parent elects to enroll the child with a provider that has a grant or...
45 CFR 98.30 - Parental choice.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Program Operations (Child Care Services)-Parental Rights and Responsibilities § 98.30 Parental choice. (a) The parent or parents of an eligible child who receives or is offered child care services shall be... available to a parent. (b) When a parent elects to enroll the child with a provider that has a grant or...
45 CFR 98.30 - Parental choice.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Program Operations (Child Care Services)-Parental Rights and Responsibilities § 98.30 Parental choice. (a) The parent or parents of an eligible child who receives or is offered child care services shall be... available to a parent. (b) When a parent elects to enroll the child with a provider that has a grant or...
45 CFR 98.30 - Parental choice.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Program Operations (Child Care Services)-Parental Rights and Responsibilities § 98.30 Parental choice. (a) The parent or parents of an eligible child who receives or is offered child care services shall be... available to a parent. (b) When a parent elects to enroll the child with a provider that has a grant or...
Federal support for state and local response operations - PHE
Electronic Benefits Transfer program, which provides summertime nutrition assistance to children who receive 15, a USDA Food and Nutrition Service nutritionist presented USDA nutrition information and menu Nutrition Program for Women, Infants, and Children (WIC) funds to conduct lead testing for WIC participants
ERIC Educational Resources Information Center
Dube, Chad; Starns, Jeffrey J.; Rotello, Caren M.; Ratcliff, Roger
2012-01-01
A classic question in the recognition memory literature is whether retrieval is best described as a continuous-evidence process consistent with signal detection theory (SDT), or a threshold process consistent with many multinomial processing tree (MPT) models. Because receiver operating characteristics (ROCs) based on confidence ratings are…
15 CFR 2004.8 - Fees in general.
Code of Federal Regulations, 2010 CFR
2010-01-01
... and printing records responsive to the FOIA request and operator/programmer salary attributable to the search. (c) Record reviews. Time devoted to reviewing records shall be charged on the same basis as under... the 20-day period described in § 2004.6(c)(1) shall be deemed to begin when the FOIA Officer receives...
15 CFR 2004.8 - Fees in general.
Code of Federal Regulations, 2011 CFR
2011-01-01
... and printing records responsive to the FOIA request and operator/programmer salary attributable to the search. (c) Record reviews. Time devoted to reviewing records shall be charged on the same basis as under... the 20-day period described in § 2004.6(c)(1) shall be deemed to begin when the FOIA Officer receives...
NASA Technical Reports Server (NTRS)
Lee, R. D. (Inventor)
1973-01-01
An intruder detection system is described. The system contains a transmitter which sends a frequency modulated and amplitude modulated signal to a remote receiver in response to a geophone detector which responds to seismic impulses created by the intruder. The signal makes it possible for an operator to determine the number of intruders and the manner of movement.
Logo Burn-In. Microcomputing Working Paper Series.
ERIC Educational Resources Information Center
Drexel Univ., Philadelphia, PA. Microcomputing Program.
This paper describes a hot-stamping operation undertaken at Drexel University in an attempt to prevent computer theft on campus. The program was initiated in response to the University's anticipated receipt of up to 3,000 Macintosh microcomputers per year and the consequent publicity the university was receiving. All clusters of computers (e.g.,…
Stationary Engineering Laboratory--2. Teacher's Guide.
ERIC Educational Resources Information Center
Steingress, Frederick M.; Frost, Harold J.
The Stationary Engineering Laboratory Manual 2 Teacher's Guide was designed as an aid to the instructors of vocational-technical high school students who have received instruction in the basics of stationary engineering. The course of study was developed for students who will be operating a live plant and who will be responsible for supplying…
Evans, Kris; Rotello, Caren M; Li, Xingshan; Rayner, Keith
2009-02-01
Cultural differences have been observed in scene perception and memory: Chinese participants purportedly attend to the background information more than did American participants. We investigated the influence of culture by recording eye movements during scene perception and while participants made recognition memory judgements. Real-world pictures with a focal object on a background were shown to both American and Chinese participants while their eye movements were recorded. Later, memory for the focal object in each scene was tested, and the relationship between the focal object (studied, new) and the background context (studied, new) was manipulated. Receiver-operating characteristic (ROC) curves show that both sensitivity and response bias were changed when objects were tested in new contexts. However, neither the decrease in accuracy nor the response bias shift differed with culture. The eye movement patterns were also similar across cultural groups. Both groups made longer and more fixations on the focal objects than on the contexts. The similarity of eye movement patterns and recognition memory behaviour suggests that both Americans and Chinese use the same strategies in scene perception and memory.
Petrini, Richard R.; Van Lue, Dorin F.
1983-01-01
A miniaturized inspection tool, for testing and inspection of metal objects in locations with difficult accessibility, which comprises eddy current sensing equipment (12) with a probe coil (11), and associated coaxial coil cable (13), coil energizing means (21), and circuit means (21, 12) responsive to impedance changes in the coil as effected by induced eddy currents in a test object to produce a data output signal proportional to such changes. The coil and cable are slideably received in the utility channel of the flexible insertion tube 17 of fiberoptic scope 10. The scope 10 is provided with light transmitting and receiving fiberoptics for viewing through the flexible tube, and articulation means (19, 20) for articulating the distal end of the tube and permitting close control of coil placement relative to a test object. The eddy current sensing equipment includes a tone generator 30 for generating audibly signals responsive to the data output signal. In one selected mode of operation, the tone generator responsive to the output signal above a selected level generates a constant single frequency tone for signalling detection of a discontinuity and, in a second selected mode, generates a tone whose frequency is proportional to the difference between the output signal and a predetermined selected threshold level.
Petrini, R.R.; Van Lue, D.F.
1983-10-25
A miniaturized inspection tool, for testing and inspection of metal objects in locations with difficult accessibility, which comprises eddy current sensing equipment with a probe coil, and associated coaxial coil cable, coil energizing means, and circuit means responsive to impedance changes in the coil as effected by induced eddy currents in a test object to produce a data output signal proportional to such changes. The coil and cable are slideably received in the utility channel of the flexible insertion tube of fiberoptic scope. The scope is provided with light transmitting and receiving fiberoptics for viewing through the flexible tube, and articulation means for articulating the distal end of the tube and permitting close control of coil placement relative to a test object. The eddy current sensing equipment includes a tone generator 30 for generating audibly signals responsive to the data output signal. In one selected mode of operation, the tone generator responsive to the output signal above a selected level generates a constant single frequency tone for signaling detection of a discontinuity and, in a second selected mode, generates a tone whose frequency is proportional to the difference between the output signal and a predetermined selected threshold level. 5 figs.
L-Band Ionosphere Scintillations Observed by A GNSS Receiver Array at HAARP
NASA Astrophysics Data System (ADS)
Morton, Y.; Pelgrum, W.; van Graas, F.
2011-12-01
As we enter a new solar maximum period, GNSS receivers, especially the ones operating in high latitude and equatorial regions, are facing an increasing threat from ionosphere scintillations. The increased solar activities, however, also offer a great opportunity to collect scintillation data to gain better understandings of scintillation effects on GNSS signals. During the past decade, many GPS receivers have been deployed around the globe to monitor ionosphere scintillations. Most of these GPS receivers are commercial receivers whose tracking mechanisms are not designed to operate under ionosphere scintillation. When strong scintillations occur, these receivers will either generate erroneous outputs or completely lose lock. Even when the scintillation is mild, the tracking loop outputs are not true representation of the signal parameters due the tracking loop transfer function. High quality, unprocessed GNSS receiver front end raw IF samples collected during ionosphere scintillations are necessary to produce realistic scintillation signal parameter estimations. In this presentation, we will update our effort in establishing a unique GNSS receiver array at HAARP, Alaska to collect GPS and GLONASS satellite signals at various stages of the GNSS receiver processing. Signal strength, carrier phase, and relative TEC measurements generated by the receiver array as well as additional on-site diagnostic instrumentation measurements obtained from two active heating experiment campaigns conducted in 2011 will be presented. Additionally, we will also highlight and contrast the artificial heating experiment results with observations of natural scintillation events captured by our receivers using an automatic event trigger mechanism during the past year. These interesting results demonstrate the feasibility and effectiveness of our experimental data collection system in providing insightful details of ionosphere responses to active perturbations and natural disturbances.
Structural analysis of a reflux pool-boiler solar receiver
NASA Astrophysics Data System (ADS)
Hoffman, E. L.; Stone, C. M.
1991-06-01
Coupled thermal-structural finite element calculations of a reflux pool-boiler solar receiver were performed to characterize the operating stresses and to address issues affecting the service life of the receiver. Analyses performed using shell elements provided information for receiver material selection and design optimization. Calculations based on linear elastic fracture mechanics principles were performed using continuum elements to assess the vulnerability of a seam-weld to fatigue crack growth. All calculations were performed using ABAQUS, a general purpose finite element code, and elements specifically formulated for coupled thermal-structural analysis. Two materials were evaluated: 316L SS and Haynes 230 alloys. The receiver response was simulated for a combination of structural and thermal loads that represent the startup and operating conditions of the receiver. For both materials, maximum stresses in the receiver developed shortly after startup due to uneven temperature distribution across the receiver surface. The largest effective stress was near yield in the 316L SS receiver and below 39 percent of yield in the Haynes 230 receiver. The calculations demonstrated that stress reductions of over 25 percent could be obtained by reducing the aft dome thickness to one closer to the absorber. The fatigue calculations demonstrated that the stress distribution near the seam-weld notch depends primarily on the structural load created by internal pressurization of the receiver rather than the thermal, indicating that the thermal loads can be neglected when assessing the stress intensity near the seam-weld notch. The stress intensity factor, computed using the J-integral method and crack opening-displacement field equations, was significantly below the fatigue threshold for most steels. The calculations indicated that the weld notch was always loaded in compression, a condition which is not conducive to fatigue crack growth.
Disaster preparedness of poison control centers in the USA: a 15-year follow-up study.
Darracq, Michael A; Clark, Richard F; Jacoby, Irving; Vilke, Gary M; DeMers, Gerard; Cantrell, F Lee
2014-03-01
There is limited published literature on the extent to which United States (US) Poison Control Centers (PCCs) are prepared for responding to disasters. We describe PCCs' disaster preparedness activities and compare and contrast these results to those previously reported in the medical literature. We also describe the extent to which PCCs are engaged in disaster and terrorism preparedness planning and other public health roles such as surveillance. An electronic questionnaire was sent via email to the managing directors of the 57 member PCCs of the American Association of Poison Control Centers. Collected data included the population served and number of calls received, extent of disaster preparedness including the presence of a written disaster plan and elements included in that plan, the presence and nature of regular disaster drills, experience with disaster including periods of inability to operate, involvement in terrorism and disaster preparedness/response policy development, and public health surveillance of US PCCs. Descriptive statistics were performed on collected data. Comparisons with the results from a previously published survey were performed. A response was obtained from 40/57 (70 %) PCCs. Each PCC serves a larger population (p < 0.0001) and receives more calls per year (p = 0.0009) than the previous descriptions of PCC preparedness. More centers report the presence of a written disaster plan (p < 0.0001), backup by another center (p < 0.0001), regular disaster drills (p < 0.0001), and comfort with ability to operate in a disaster (p < 0.0001) than previously described. PCCs are involved in disaster (34/40, 85 %) and terrorism (29/40, 73 %) preparedness at the local, state, or federal levels. PCCs (36/40, 90 %) are also involved in public health functions (illness surveillance or answering "after hours" public health calls). Despite an increase in calls received and population served per center as compared to previous descriptions, more PCCs report the presence of a written disaster plan, backup by another center, regular disaster drills, and comfort in ability to operate in a disaster. PCCs are actively involved in terrorism and disaster preparedness and response planning and traditional public health responsibilities such as surveillance.
Leasing of federal geothermal resources
NASA Technical Reports Server (NTRS)
Stone, R. T.
1974-01-01
Pursuant to the Geothermal Steam Act of 1970 and the regulations published on December 21, 1973, the first Federal geothermal competitive lease sale was held on January 22, 1974, by the Department of the Interior, offering 33 tracts totalling over 50,000 acres in three Known Geothermal Resource Areas in California. On January 1, 1974, Federal lands outside Known Geothermal Resource Areas were opened to noncompetitive lease applications, of which, 3,763 had been received by June 1, 1974. During fiscal year 1974, a total of 22 competitive leases had been issued in California and Oregon. The principal components in the Department involved in the leasing program are the Geological Survey and the Bureau of Land Management. The former has jurisdiction over drilling and production operations and other activities in the immediate area of operations. The latter receives applications and issues leases and is responsible for managing leased lands under its jurisdiction outside the area of operations. The interrelationships of the above agencies and the procedures in the leasing program are discussed.
NASA Astrophysics Data System (ADS)
Chen, Kai; Wei, Wen-Bo; Deng, Ming; Wu, Zhong-Liang; Yu, Gang
2015-09-01
In planning and executing marine controlled-source electromagnetic methods, seafloor electromagnetic receivers must overcome the problems of noise, clock drift, and power consumption. To design a receiver that performs well and overcomes the abovementioned problems, we performed forward modeling of the E-field abnormal response and established the receiver's characteristics. We describe the design optimization and the properties of each component, that is, low-noise induction coil sensor, low-noise Ag/AgCl electrode, low-noise chopper amplifier, digital temperature-compensated crystal oscillator module, acoustic telemetry modem, and burn wire system. Finally, we discuss the results of onshore and offshore field tests to show the effectiveness of the developed seafloor electromagnetic receiver and its performance: typical E-field noise of 0.12 nV/m/rt(Hz) at 0.5 Hz, dynamic range higher than 120 dB, clock drift lower than 1 ms/day, and continuous operation of at least 21 days.
[Patient information prior to sterilization].
Rasmussen, O V; Henriksen, L O; Baldur, B; Hansen, T
1992-09-14
The law in Denmark prescribes that the patient and the general practitioner to whom the patient directs his or her request for sterilization are obliged to confirm by their signatures that the patient has received information about sterilization, its risk and consequences. We asked 97 men and 96 women, if they had received this information prior to their sterilization. They were also asked about their knowledge about sterilization. 54% of the women and 35% of the men indicated that they had not received information. Only few of these wished further information by the hospital doctor. Knowledge about sterilization was good. It is concluded that the information to the patient prior to sterilization is far from optimal. The patients' signature confirming verbal information is not a sufficient safeguard. We recommend, among other things, that the patient should receive written information and that both the general practitioner and the hospital responsible for the operation should ensure that optimal information is received by the patient.
Optical rectenna operation: where Maxwell meets Einstein
NASA Astrophysics Data System (ADS)
Joshi, Saumil; Moddel, Garret
2016-07-01
Optical rectennas are antenna-coupled diode rectifiers that receive and convert optical-frequency electromagnetic radiation into DC output. The analysis of rectennas is carried out either classically using Maxwell’s wave-like approach, or quantum-mechanically using Einstein’s particle-like approach for electromagnetic radiation. One of the characteristics of classical operation is that multiple photons transfer their energy to individual electrons, whereas in quantum operation each photon transfers its energy to each electron. We analyze the correspondence between the two approaches by comparing rectenna response first to monochromatic illumination obtained using photon-assisted tunnelling theory and classical theory. Applied to broadband rectenna operation, this correspondence provides clues to designing a rectenna solar cell that has the potential to exceed the 44% quantum-limited conversion efficiency. The comparison of operating regimes shows how optical rectenna operation differs from microwave rectenna operation.
The factors influencing the decision making of operative treatment for proximal humeral fractures.
Hageman, Michiel G J S; Jayakumar, Prakash; King, John D; Guitton, Thierry G; Doornberg, Job N; Ring, David
2015-01-01
The factors influencing the decision making of operative treatment for fractures of the proximal humerus are debated. We hypothesized that there is no difference in treatment recommendations between surgeons shown radiographs alone and those shown radiographs and patient information. Secondarily, we addressed (1) factors associated with a recommendation for operative treatment, (2) factors associated with recommendation for arthroplasty, (3) concordance with the recommendations of the treating surgeons, and (4) factors affecting the inter-rater reliability of treatment recommendations. A total of 238 surgeons of the Science of Variation Group rated 40 radiographs of patients with proximal humerus fractures. Participants were randomized to receive information about the patient and mechanism of injury. The response variables included the choice of treatment (operative vs nonoperative) and the percentage of matches with the actual treatment. Participants who received patient information recommended operative treatment less than those who received no information. The patient information that had the greatest influence on treatment recommendations included age (55%) and fracture mechanism (32%). The only other factor associated with a recommendation for operative treatment was region of practice. There was no significant difference between participants who were and were not provided with information regarding agreement with the actual treatment (operative vs nonoperative) provided by the treating surgeon. Patient information-older age in particular-is associated with a higher likelihood of recommending nonoperative treatment than radiographs alone. Clinical information did not improve agreement of the Science of Variation Group with the actual treatment or the generally poor interobserver agreement on treatment recommendations. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Yang; Chen, Hung-Yu; Liang, Kevin; Wei, Liang-Yu; Chow, Chi-Wai; Yeh, Chien-Hung
2016-01-01
Traditional visible light communication (VLC) uses positive-intrinsic-negative photodiode (PD) or avalanche PD as the optical receivers (Rx). We demonstrate using a solar cell as the VLC Rx. The solar cell is flexible and low cost and converts the optical signal into an electrical signal directly without the need of external power supply. In addition to acting as the VLC passive Rx, the converted electrical signal from the solar cell can charge up the battery of the Rx nodes. Hence, the proposed scheme can be a promising candidate for the future Internet of Things network. However, a solar cell acting as a VLC Rx is very challenging, since the response of the solar cell is limited. Here, we propose and demonstrate using predistortion to significantly enhance the solar cell Rx response for the first time up to the authors' knowledge. Experimental results show that the response of the solar cell Rx is significantly enhanced; and the original 2-kHz detection bandwidth of the solar cell can be enhanced by 250 times for receiving 500-kbit/s VLC signal at a transmission distance of 1 m. The operation principle, the generated voltage by the solar cell, and the maximum data rates achieved at different transmission distances are also studied.
Characteristics of High Latitude Ionosphere Scintillations
NASA Astrophysics Data System (ADS)
Morton, Y.
2012-12-01
As we enter a new solar maximum period, global navigation satellite systems (GNSS) receivers, especially the ones operating in high latitude and equatorial regions, are facing an increasing threat from ionosphere scintillations. The increased solar activities, however, also offer a great opportunity to collect scintillation data to characterize scintillation signal parameters and ionosphere irregularities. While there are numerous GPS receivers deployed around the globe to monitor ionosphere scintillations, most of them are commercial receivers whose signal processing mechanisms are not designed to operate under ionosphere scintillation. As a result, they may distort scintillation signal parameters or lose lock of satellite signals under strong scintillations. Since 2008, we have established and continuously improved a unique GNSS receiver array at HAARP, Alaska. The array contains high ends commercial receivers and custom RF front ends which can be automatically triggered to collect high quality GPS and GLONASS satellite signals during controlled heating experiments and natural scintillation events. Custom designed receiver signal tracking algorithms aim to preserve true scintillation signatures are used to process the raw RF samples. Signal strength, carrier phase, and relative TEC measurements generated by the receiver array since its inception have been analyzed to characterize high latitude scintillation phenomena. Daily, seasonal, and solar events dependency of scintillation occurrence, spectral contents of scintillation activities, and plasma drifts derived from these measurements will be presented. These interesting results demonstrate the feasibility and effectiveness of our experimental data collection system in providing insightful details of ionosphere responses to active perturbations and natural disturbances.
A Sub-millimeter, Inductively Powered Neural Stimulator
Freeman, Daniel K.; O'Brien, Jonathan M.; Kumar, Parshant; Daniels, Brian; Irion, Reed A.; Shraytah, Louis; Ingersoll, Brett K.; Magyar, Andrew P.; Czarnecki, Andrew; Wheeler, Jesse; Coppeta, Jonathan R.; Abban, Michael P.; Gatzke, Ronald; Fried, Shelley I.; Lee, Seung Woo; Duwel, Amy E.; Bernstein, Jonathan J.; Widge, Alik S.; Hernandez-Reynoso, Ana; Kanneganti, Aswini; Romero-Ortega, Mario I.; Cogan, Stuart F.
2017-01-01
Wireless neural stimulators are being developed to address problems associated with traditional lead-based implants. However, designing wireless stimulators on the sub-millimeter scale (<1 mm3) is challenging. As device size shrinks, it becomes difficult to deliver sufficient wireless power to operate the device. Here, we present a sub-millimeter, inductively powered neural stimulator consisting only of a coil to receive power, a capacitor to tune the resonant frequency of the receiver, and a diode to rectify the radio-frequency signal to produce neural excitation. By replacing any complex receiver circuitry with a simple rectifier, we have reduced the required voltage levels that are needed to operate the device from 0.5 to 1 V (e.g., for CMOS) to ~0.25–0.5 V. This reduced voltage allows the use of smaller receive antennas for power, resulting in a device volume of 0.3–0.5 mm3. The device was encapsulated in epoxy, and successfully passed accelerated lifetime tests in 80°C saline for 2 weeks. We demonstrate a basic proof-of-concept using stimulation with tens of microamps of current delivered to the sciatic nerve in rat to produce a motor response. PMID:29230164
Code of Federal Regulations, 2010 CFR
2010-07-01
... of an annual evaluation of a concessioner's performance may not occur until after the selection of the best proposal submitted in response to a prospectus, the Director will make an annual performance... performance evaluation. In the event the concessioner receives a second less than satisfactory annual...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-22
... workstations located in the trading crowds for manual handling, and/ or to other order management terminals... orders that they receive at their PAR workstations at the best prices available to them under the... responsible for (a) operating the PAR workstation in a DPM trading crowd with respect to the classes of...
ERIC Educational Resources Information Center
Trippas, Dries; Handley, Simon J.; Verde, Michael F.
2013-01-01
When people evaluate conclusions, they are often influenced by prior beliefs. Prevalent theories claim that "belief bias" affects the quality of syllogistic reasoning. However, recent work by Dube, Rotello, and Heit (2010) has suggested that belief bias may be a simple response bias. In Experiment 1, receiver operating characteristic…
1975-01-01
Receiver operating characteristic (ROC) analysis of nerve messages is described. The hypothesis that quantum fluctuations provide the only limit to the ability of frog ganglion cells to signal luminance change information is examined using ROC analysis. In the context of ROC analysis, the quantum fluctuation hypothesis predicts (a) the detectability of a luminance change signal should rise proportionally to the size of the change, (b) detectability should decrease as the square root of background, an implication of which is the deVries-Rose law, and (c) ROC curves should exhibit a shape particular to underlying Poisson distributions. Each of these predictions is confirmed for the responses of dimming ganglion cells to brief luminance decrements at scotopic levels, but none could have been tested using classical nerve message analysis procedures. PMID:172597
Method and systems for a radiation tolerant bus interface circuit
NASA Technical Reports Server (NTRS)
Kinstler, Gary A. (Inventor)
2007-01-01
A bus management tool that allows communication to be maintained between a group of nodes operatively connected on two busses in the presence of radiation by transmitting periodically a first message from one to another of the nodes on one of the busses, determining whether the first message was received by the other of the nodes on the first bus, and when it is determined that the first message was not received by the other of the nodes, transmitting a recovery command to the other of the nodes on a second of the of busses. Methods, systems, and articles of manufacture consistent with the present invention also provide for a bus recovery tool on the other node that re-initializes a bus interface circuit operatively connecting the other node to the first bus in response to the recovery command.
Lahner, D; Kabon, B; Marschalek, C; Chiari, A; Pestel, G; Kaider, A; Fleischmann, E; Hetz, H
2009-09-01
Fluid management guided by oesophageal Doppler monitor has been reported to improve perioperative outcome. Stroke volume variation (SVV) is considered a reliable clinical predictor of fluid responsiveness. Consequently, the aim of the present trial was to evaluate the accuracy of SVV determined by arterial pulse contour (APCO) analysis, using the FloTrac/Vigileo system, to predict fluid responsiveness as measured by the oesophageal Doppler. Patients undergoing major abdominal surgery received intraoperative fluid management guided by oesophageal Doppler monitoring. Fluid boluses of 250 ml each were administered in case of a decrease in corrected flow time (FTc) to <350 ms. Patients were connected to a monitoring device, obtaining SVV by APCO. Haemodynamic variables were recorded before and after fluid bolus application. Fluid responsiveness was defined as an increase in stroke volume index >10%. The ability of SVV to predict fluid responsiveness was assessed by calculation of the area under the receiver operating characteristic (ROC) curve. Twenty patients received 67 fluid boluses. Fifty-two of the 67 fluid boluses administered resulted in fluid responsiveness. SVV achieved an area under the ROC curve of 0.512 [confidence interval (CI) 0.32-0.70]. A cut-off point for fluid responsiveness was found for SVV > or =8.5% (sensitivity: 77%; specificity: 43%; positive predictive value: 84%; and negative predictive value: 33%). This prospective, interventional observer-blinded study demonstrates that SVV obtained by APCO, using the FloTrac/Vigileo system, is not a reliable predictor of fluid responsiveness in the setting of major abdominal surgery.
A Methodology for Training International Space Station Crews to Respond to On-Orbit Emergencies
NASA Technical Reports Server (NTRS)
Balmain, Clinton; Fleming, Mark
2009-01-01
Most spaceflight crewmembers agree that emergency training is among the most important training they receive. If an emergency event occurs on-orbit crewmembers want to be able to rely on a thorough and proficient knowledge of emergency operations and procedures. The inherent complexity of ISS and the international nature of the onboard operations have resulted in emergency procedures that are complex by any measure; as a result, a very robust apparatus has been developed to give crewmembers initial training on emergency procedures and ensure proficiency up to (and even after) launch. One of the most important aspects of complex onboard operations in general, and emergency operations specifically, is learning how to coordinate roles and responsibilities with fellow crewmembers. A primary goal of NASA s emergency training program is to allow the crewmembers who will actually be together on-orbit to practice executing the emergency responses together before they fly. As with any operation that includes the use of software and hardware, the fidelity of the simulation environment is a critical element to successful training. The NASA training division has spent considerable time and effort to develop a simulator that addresses the most important aspects of emergency response, working within very difficult space and budgetary constraints.
Krank, Marvin D
2003-10-01
Conditioned incentive theories of addictive behavior propose that cues signaling a drug's reinforcing effects activate a central motivational state. Incentive motivation enhances drug-taking and drug-seeking behavior. We investigated the behavioral response to cues associated with ethanol and their interaction with operant self-administration of ethanol. In two experiments, rats received operant training to press a lever for a sweetened ethanol solution. After operant training, the animals were given Pavlovian pairings of a brief and localized cue light with the sweetened ethanol solution (no lever present). Lever pressing for ethanol was then re-established, and the behavioral effects of the cue light were tested during an ethanol self-administration session. The conditioned responses resulting from pairing cue lights with the opportunity to ingest ethanol had three main effects: (1) induction of operant behavior reinforced by ethanol, (2) stimulation of ethanol-seeking behavior (magazine entries), and (3) signal-directed behavior (i.e., autoshaping, or sign-tracking). Signal-directed behavior interacted with the other two effects in a manner predicted by the location of the cue light. These conditioned responses interact with operant responding for ethanol reinforcement. These findings demonstrate the importance of Pavlovian conditioning effects on ethanol self-administration and are consistent with conditioned incentive theories of addictive behavior.
Spaceborne receivers: Basic principles
NASA Technical Reports Server (NTRS)
Stacey, J. M.
1984-01-01
The underlying principles of operation of microwave receivers for space observations of planetary surfaces were examined. The design philosophy of the receiver as it is applied to operate functionally as an efficient receiving system, the principle of operation of the key components of the receiver, and the important differences among receiver types are explained. The operating performance and the sensitivity expectations for both the modulated and total power receiver configurations are outlined. The expressions are derived from first principles and are developed through the important intermediate stages to form practicle and easily applied equations. The transfer of thermodynamic energy from point to point within the receiver is illustrated. The language of microwave receivers is applied statistics.
Abuse Pattern of Toluene Exposure Alters Mouse Behavior in a Waiting-for-Reward Operant Task
Bowen, Scott E.; McDonald, Phillip
2009-01-01
Inhaling solvents for recreational purposes continues to be a world-wide public health concern. Toluene, a volatile solvent in many abused products, adversely affects the central nervous system. However, the long-term neurobehavioral effects of exposure to high-concentration, binge patterns typical of toluene abuse remain understudied. We studied the behavioral effects of repeated toluene exposure on cognitive function following binge toluene exposure on behavioral impulse control in Swiss Webster mice using a “wait-for-reward” operant task. Mice were trained on a fixed-ratio (FR) schedule using sweetened milk as a reward. Upon achieving FR15, a wait component was added which delivered free rewards in the absence of responses at increasing time intervals (2 sec, 4 sec, 6 sec, etc…). Mice continued to receive free rewards until they pressed a lever that reinstated the FR component (FR Reset). Once proficient in the FR-Wait task, mice were exposed to either 1,000 ppm, 3,600 ppm or 6,000 ppm toluene, or 0 ppm (air controls) for 30 min per day for 40 days. To avoid acute effects of toluene exposure, behavior was assessed 23 hours later. Repeated toluene exposure decreased response rates, the number of FR resets, and increased mean wait time, resulting in a higher response-to-reinforcer ratio than exhibited by controls. Mice receiving the higher exposure level (6,000 ppm) showed a dramatic decrease in the number of rewards received, which was reversed when toluene exposure ceased. Mice receiving the lower exposure level (1,000 ppm) showed little change in the number of rewards. These results indicate that repeated binge exposures to high concentrations of toluene can significantly interfere with performance as measured by a waiting-for-reward task, suggesting a significant impact on cognitive and/or psychomotor function. PMID:18832024
A comparison of ROC inferred from FROC and conventional ROC
NASA Astrophysics Data System (ADS)
McEntee, Mark F.; Littlefair, Stephen; Pietrzyk, Mariusz W.
2014-03-01
This study aims to determine whether receiver operating characteristic (ROC) scores inferred from free-response receiver operating characteristic (FROC) were equivalent to conventional ROC scores for the same readers and cases. Forty-five examining radiologists of the American Board of Radiology independently reviewed 47 PA chest radiographs under at least two conditions. Thirty-seven cases had abnormal findings and 10 cases had normal findings. Half the readers were asked to first locate any visualized lung nodules, mark them and assign a level of confidence [the FROC mark-rating pair] and second give an overall to the entire image on the same scale [the ROC score]. The second half of readers gave the ROC rating first followed by the FROC mark-rating pairs. A normal image was represented with number 1 and malignant lesions with numbers 2-5. A jackknife free-response receiver operating characteristic (JAFROC), and inferred ROC (infROC) was calculated from the mark-rating pairs using JAFROC V4.1 software. ROC based on the overall rating of the image calculated using DBM MRMC software, which was also used to compare infROC and ROC AUCs treating the methods as modalities. Pearson's correlations coefficient and linear regression were used to examine their relationship using SPSS, version 21.0; (SPSS, Chicago, IL). The results of this study showed no significant difference between the ROC and Inferred ROC AUCs (p≤0.25). While Pearson's correlation coefficient was 0.7 (p≤0.01). Inter-reader correlation calculated from Obuchowski- Rockette covariance's ranged from 0.43-0.86 while intra-reader agreement was greater than previously reported ranging from 0.68-0.82.
Solar thermochemical processing system and method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wegeng, Robert S.; Humble, Paul H.; Krishnan, Shankar
A solar thermochemical processing system is disclosed. The system includes a first unit operation for receiving concentrated solar energy. Heat from the solar energy is used to drive the first unit operation. The first unit operation also receives a first set of reactants and produces a first set of products. A second unit operation receives the first set of products from the first unit operation and produces a second set of products. A third unit operation receives heat from the second unit operation to produce a portion of the first set of reactants.
Eder, Andreas B; Rothermund, Klaus; Proctor, Robert W
2010-08-01
Advance preparation of action courses toward emotional stimuli is an effective means to regulate impulsive emotional behavior. Our experiment shows that performing intentional acts of approach and avoidance in an evaluation task influences the unintended activation of approach and avoidance tendencies in another task in which stimulus valence is irrelevant. For the evaluation-relevant blocks, participants received either congruent (positive-approach, negative-avoidance) or incongruent (positive-avoidance, negative-approach) mapping instructions. In the evaluation-irrelevant blocks, approach- and avoidance-related lever movements were selected in response to a stimulus feature other than valence (affective Simon task). Response mapping in the evaluation task influenced performance in the evaluation-irrelevant task: An enhanced affective Simon effect was observed with congruent mapping instructions; in contrast, the effect was reversed when the evaluation task required incongruent responses. Thus, action instructions toward affective stimuli received in one task determined affective response tendencies in another task where these instructions were not in effect. These findings suggest that intentionally prepared short-term links between affective valence and motor responses elicit associated responses without a deliberate act of will, operating like a "prepared reflex." Copyright 2010 APA
Internal controls over computer-processed financial data at Boeing Petroleum Services
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1992-02-14
The Strategic Petroleum Reserve (SPR) is responsible for purchasing and storing crude oil to mitigate the potential adverse impact of any future disruptions in crude oil imports. Boeing Petroleum Services, Inc. (BPS) operates the SPR under a US Department of Energy (DOE) management and operating contract. BPS receives support for various information systems and other information processing needs from a mainframe computer center. The objective of the audit was to determine if the internal controls implemented by BPS for computer systems were adequate to assure processing reliability.
Kashefi Marandi, Aref; Shojaiefard, Abolfazl; Soroush, Ahmadreza; Ghorbani Abdegah, Ali; Jafari, Mehdi; Khodadost, Mahmoud; Mahmoudzade, Hossein
2016-01-01
Gastroesophageal cancer is one of the most common types of cancer worldwide. Despite significant developments in management, 5-year survival in the developing world is less than 20 percent. Due to restricted research about the impact of preoperative chemotherapy (POC) on tumor resection, pathological response and postoperative complications in Iran, we designed and implemented the present retrospective cross- sectional study on 156 patients with gastroesophageal cancer (GEc) between 2013 and 2015 at Shariati Hospital of Tehran. Two groups were included, the first group had previously received preoperative chemotherapy and the second group had only undergone surgery. All patients were followed for at least one year after the operation in terms of tumor recurrence, relapse free survival and one-year survival. The two groups were eventually compared regarding tumor resection, pathological response, postoperative complications, recurrence rate and survival. The mean age was 66.5± 7.3 years and 78 percent were male. The tumor resectability, pathological response and postoperative complications in the group which received POC were 93.5%, 21.8% and 12.8%, respectively, and in the surgery alone group figures for tumor resection and postoperative complications were 76% and 29.5%, respectively. Also based on our study the 5-year survival in the POC group was better (79.5% vs. 66.5%). Using standard neoadjuvant regimens (preoperative chemotherapy/ chemoradiotherapy) beforesurgery could increase tumor resectability, pathological response, and improve the general status of the patients. Therefore using POC may be recommended over surgery alone.
Tomita, Tetsu; Yasui-Furukori, Norio; Norio, Yasui-Furukori; Sato, Yasushi; Nakagami, Taku; Tsuchimine, Shoko; Kaneda, Ayako; Kaneko, Sunao
2014-01-01
We investigated cutoff values for the early response of patients with major depressive disorder to paroxetine and their sex differences by using a receiver operating characteristic (ROC) curve analysis to predict the effectiveness of paroxetine. In total, 120 patients with major depressive disorder were enrolled and treated with 10-40 mg/day paroxetine for 6 weeks; 89 patients completed the protocol. A clinical evaluation using the Montgomery-Asberg Depression Rating Scale (MADRS) was performed at weeks 0, 1, 2, 4, and 6. In male subjects, the cutoff values for MADRS improvement rating in week 1, week 2, and week 4 were 20.9%, 34.9%, and 33.3%, respectively. The sensitivities and the specificities were 83.3% and 80.0%, 83.3% and 80.0%, and 100% and 90%, respectively. The areas under the curve (AUC) were 0.908, 0.821, and 0.979, respectively. In female subjects, the cutoff values for the MADRS improvement rating in week 1, week 2, and week 4 were 21.4%, 35.7%, and 32.3%, respectively. The sensitivities and the specificities were 71.4% and 84.6%, 73.8% and 76.9%, and 90.5% and 76.9%, respectively. The AUCs were 0.781, 0.735, and 0.904, respectively. Early improvement with paroxetine may predict the long-term response. The accuracy of the prediction for the response is higher in male subjects.
Marshall Installs Receiving Antenna for Next-Generation Weather Satellites
2016-12-16
Technicians assemble a hefty segment of a new antenna system in this 30-second time-lapse video captured Dec. 16 at NASA's Marshall Space Flight Center. The high-performance ground station is designed to receive meteorological and space weather data from instruments flown on the National Oceanic and Atmospheric Administration's new, game-changing Geostationary Operational Environmental Satellite series. The six-meter dish antenna near Building 4316 expands the capacity of Marshall’s Earth Science Office to use real-time GOES observations for studies of Earth and to deliver new forecasting, warning and disaster response tools to partners around the world. (NASA/MSFC)
Zollinger, Paul E; Kreis, Robert W; van der Meulen, Hub G; van der Elst, Maarten; Breederveld, Roelf S; Tuinebreijer, Wim E
2010-02-17
Operative and conservative treatment of wrist fractures might lead to complex regional pain syndrome (CRPS) type I.In our multicenter dose response study in which patients with distal radial fractures were randomly allocated to placebo or vitamin C in a daily dose of 200mg, 500mg or 1500mg during 50 days, an operated subgroup was analyzed.48 (of 427) fractures) were operated (11.2%). Twenty-nine patients (60%) were treated with external fixation, 14 patients (29%) with K-wiring according to Kapandji and five patients (10%) with internal plate fixation. The 379 remaining patients were treated with a plaster.In the operated group of patients who received vitamin C no CRPS (0/37) was seen in comparison with one case of CRPS (Kapandji technique) in the operated group who received placebo (1/11 = 9%, p=.23). There was no CRPS after external fixation.In the conservatively treated group 17 cases of CRPS (17/379 = 4.5%) occurred in comparison with one in case of CRPS in the operated group (1/48 = 2.1%, p=.71).External fixation doesn't necessarily lead to a higher incidence of CRPS in distal radial fractures. Vitamin C may also play a role in this. This subgroup analysis in operated distal radial fractures showed no CRPS occurrence with vitamin C prophylaxis.
Ploense, Kyle L; Kerstetter, Kerry A; Wade, Matthew A; Woodward, Nicholas C; Maliniak, Dan; Reyes, Michael; Uchizono, Russell S; Bredy, Timothy W; Kippin, Tod E
2013-06-01
Histone deacetylase inhibitors (HDACIs) strengthen memory following fear conditioning and cocaine-induced conditioned place preference. Here, we examined the effects of two nonspecific HDACIs, valproic acid (VPA) and sodium butyrate (NaB), on appetitive learning measured by conditioned stimulus (CS)-induced reinstatement of operant responding. Rats were trained to lever press for food reinforcement and then injected with VPA (50-200 mg/kg, i.p.), NaB (250-1000 mg/kg, i.p.), or saline vehicle (1.0 ml/kg), 2 h before receiving pairings of noncontingent presentation of food pellets preceded by a tone+light cue CS. Rats next underwent extinction of operant responding followed by response-contingent re-exposure to the CS. Rats receiving VPA (100 mg/kg) or NaB (1000 mg/kg) before conditioning displayed significantly higher cue-induced reinstatement than did saline controls. Rats that received either vehicle or VPA (100 mg/kg) before a conditioning session with a randomized relation between presentation of food pellets and the CS failed to show subsequent cue-induced reinstatement with no difference between the two groups. These findings indicate that, under certain contexts, HDACIs strengthen memory formation by specifically increasing the associative strength of the CS, not through an increasing motivation to seek reinforcement. © 2013 Wolters Kluwer Health | Lippincott Williams & Wilkins.
Ploense, Kyle L.; Kerstetter, Kerry A.; Wade, Matthew A.; Woodward, Nicholas C.; Maliniak, Dan; Reyes, Michael; Uchizono, Russell S.; Bredy, Timothy W.; Kippin, Tod E.
2014-01-01
Histone deacetylase inhibitors (HDACIs) strengthen memory following fear conditioning and cocaine-induced conditioned place preference. Here, we examined the effects of two non-specific HDACIs, valproic acid (VPA) and sodium butyrate (NaB), on appetitive learning measured via conditioned stimulus (CS)-induced reinstatement of operant responding. Rats were trained to lever press for food reinforcement and then injected with VPA (50–200 mg/kg, i.p.), NaB (250–1000 mg/kg, i.p.), or saline vehicle (1.0 ml/kg), 2h before receiving pairings of noncontingent presentation of food pellets preceded by a tone+light cue CS. Rats next underwent extinction of operant responding followed by response-contingent re-exposure to the CS. Rats receiving VPA (100 mg/kg) or NaB (1000 mg/kg) prior to conditioning displayed significantly higher cue-induced reinstatement than did saline controls. Rats that receiving either vehicle or VPA (100 mg/kg) prior to a conditioning session with a randomized relation between presentation of food pellets and the CS failed to show subsequent cue-induced reinstatement with no difference between the two groups. These findings indicate that, under certain contexts, HDACIs strengthen memory formation by specifically increasing the associative strength of the CS, not through an increasing motivation to seek reinforcement. PMID:23604166
Reducing spontaneous recovery and reinstatement of operant performance through extinction-cues.
Bernal-Gamboa, Rodolfo; Gámez, A Matías; Nieto, Javier
2017-02-01
It has been argued that the response recovery effects share a common mechanism. A possible way to test it is evaluating whether the techniques that impaired renewal would impair the other recovery effects as well. Two experiments with rats used a free operant procedure to explore whether an extinction-cue could prevent the spontaneous recovery and reinstatement of an extinguished lever-pressing. Both experiments consisted of four phases: Acquisition, Extinction and Test 1 and Test 2. First, all rats were trained to perform one instrumental response (R1) for food in context A, and a different instrumental response (R2) for food in context B. Then, responses were extinguished within the same context: R1 in context A and R2 in context B. Throughout this phase all rats received brief presentations of a tone (extinction-cue). In both experiments animals were tested twice. The first test was conducted immediately after the last extinction session. In this test, rats received the extinction-cue for both responses. During the second test, rats experienced the tone only for R1. In Experiment 1 rats were tested after 5days, while for Experiment 2 test 2 took place after a single session of re-exposure to the food. Both experiments showed a recovery effect (spontaneous recovery in Experiment 1 and reinstatement in Experiment 2) for both responses. However, a cue featured in extinction attenuated recovery of R1 in both experiments when presented on the test. The findings suggest that spontaneous recovery, reinstatement and renewal might share a common mechanism. In addition, the present data shows that using an extinction-cue could help to reduces relapsing of voluntary behaviors. Copyright © 2016 Elsevier B.V. All rights reserved.
Sasaki, Shin; Kojima, Tetsu; Hidemura, Akio; Hatanaka, Kazuhito; Uekusa, Toshimasa; Ishimaru, Masahiro
2010-10-01
We report herein the case of a 64-year-old male who presented with hematochezia. The patient was diagnosed with malignant melanoma of the anorectum using colonoscopy. Preoperative studies revealed no distant metastases, and he underwent Miles operation. Pathological exams revealed that the tumor had invaded the submucosa with lymphatic and venous invasion. Cancer cells were found in regional lymph nodes. Post-operative CT scan demonstrated multiple metastases in the liver, and he received two courses of combined chemotherapy, DAV regimen (dacarbazine: DTIC 100 mg iv days 1-5, nimustine hydrochloride: ACNU 100 mg iv day 1, vincristine sulfate: VCR 1 mg iv day 1), leading to a complete response. However, malignant melanoma cells were found in hernia contents at the operation for left inguinal hernia, which led to a diagnosis of recurrent malignant melanoma. The patient has subsequently been well without any sign of recurrence including liver metastases. To our knowledge, this is the first report of a complete response in a patient with multiple liver metastases of anorectal malignant melanoma after DAV regimen.
Sethi, Rakesh; Naqash, Imtiaz A; Bajwa, Sukhminder Jit Singh; Dutta, Vikas; Ramzan, Altaf Umar; Zahoor, Syed Amir
2016-01-01
The glucocorticoid dexamethasone in a bolus dose of 8-10 mg followed by quarterly dose of 4 mg is commonly used during intracranial surgery so as to reduce oedema and vascular permeability. However, the detrimental hyperglycaemic effects of dexamethasone may override its potentially beneficial effects. The present prospective, randomised study aimed at comparing the degree and magnitude of hyperglycaemia induced by prophylactic administration of dexamethasone in patients undergoing elective craniotomy. Sixty American Society of Anaesthesiologist (ASA) grade-I and II patients were randomly assigned to three groups of 20 patients each. Group-I received dexamethasone during surgery for the first time. Group-II received dexamethasone in addition to receiving it pre-operatively, whereas Group-III (control group) patients were administered normal saline as placebo. Baseline blood glucose (BG) was measured in all the three groups before induction of anaesthesia and thereafter after every hour for 4 h and then two-hourly. Besides intra- and intergroup comparison of BG, peak BG concentration was also recorded for each patient. Statistical analysis was carried out with analysis of variance (ANOVA) and Student's t-test and value of P < 0.05 was considered statistically significant. Baseline BG reading were higher and statistically significant in Group-II as compared with Group-I and Group-III (P < 0.05). However, peak BG levels were significantly higher in Group-I than in Group-II and III (P < 0.05). Similarly, the magnitude of change in peak BG was significantly higher in Group-I as compared to Group-II and III (P < 0.05). Peri-operative administration of dexamethasone during neurosurgical procedures can cause significant increase in BG concentration especially in patients who receive dexamethasone intra-operatively only.
Sethi, Rakesh; Naqash, Imtiaz A.; Bajwa, Sukhminder Jit Singh; Dutta, Vikas; Ramzan, Altaf Umar; Zahoor, Syed Amir
2016-01-01
Background and Aim: The glucocorticoid dexamethasone in a bolus dose of 8-10 mg followed by quarterly dose of 4 mg is commonly used during intracranial surgery so as to reduce oedema and vascular permeability. However, the detrimental hyperglycaemic effects of dexamethasone may override its potentially beneficial effects. The present prospective, randomised study aimed at comparing the degree and magnitude of hyperglycaemia induced by prophylactic administration of dexamethasone in patients undergoing elective craniotomy. Materials and Methods: Sixty American Society of Anaesthesiologist (ASA) grade-I and II patients were randomly assigned to three groups of 20 patients each. Group-I received dexamethasone during surgery for the first time. Group-II received dexamethasone in addition to receiving it pre-operatively, whereas Group-III (control group) patients were administered normal saline as placebo. Baseline blood glucose (BG) was measured in all the three groups before induction of anaesthesia and thereafter after every hour for 4 h and then two-hourly. Besides intra- and intergroup comparison of BG, peak BG concentration was also recorded for each patient. Statistical analysis was carried out with analysis of variance (ANOVA) and Student's t-test and value of P < 0.05 was considered statistically significant. Results: Baseline BG reading were higher and statistically significant in Group-II as compared with Group-I and Group-III (P < 0.05). However, peak BG levels were significantly higher in Group-I than in Group-II and III (P < 0.05). Similarly, the magnitude of change in peak BG was significantly higher in Group-I as compared to Group-II and III (P < 0.05). Conclusion: Peri-operative administration of dexamethasone during neurosurgical procedures can cause significant increase in BG concentration especially in patients who receive dexamethasone intra-operatively only. PMID:27057213
Missed deadline notification in best-effort schedulers
NASA Astrophysics Data System (ADS)
Banachowski, Scott A.; Wu, Joel; Brandt, Scott A.
2003-12-01
It is common to run multimedia and other periodic, soft real-time applications on general-purpose computer systems. These systems use best-effort scheduling algorithms that cannot guarantee applications will receive responsive scheduling to meet deadline or timing requirements. We present a simple mechanism called Missed Deadline Notification (MDN) that allows applications to notify the system when they do not receive their desired level of responsiveness. Consisting of a single system call with no arguments, this simple interface allows the operating system to provide better support for soft real-time applications without any a priori information about their timing or resource needs. We implemented MDN in three different schedulers: Linux, BEST, and BeRate. We describe these implementations and their performance when running real-time applications and discuss policies to prevent applications from abusing MDN to gain extra resources.
"Good Books": Is There a Future for Academic Writing within the Educational Publishing Industry?
ERIC Educational Resources Information Center
Nixon, Jon; Wellington, Jerry
2005-01-01
This paper draws on questionnaire responses received (via e-mail) during the period 2002-2003 from senior commissioning editors located within seven of the major UK publishing outlets. Drawing on the analytical framework of an earlier study by Nixon (1999), it focuses on the mediation of educational studies by market forces operating within and…
The Belief Bias Effect Is Aptly Named: A Reply to Klauer and Kellen (2011)
ERIC Educational Resources Information Center
Dube, Chad; Rotello, Caren M.; Heit, Evan
2011-01-01
In "Assessing the Belief Bias Effect With ROCs: It's a Response Bias Effect," Dube, Rotello, and Heit (2010) examined the form of receiver operating characteristic (ROC) curves for reasoning and the effects of belief bias on measurement indices that differ in whether they imply a curved or linear ROC function. We concluded that the ROC…
49 CFR 232.211 - Class III brake tests-trainline continuity inspection.
Code of Federal Regulations, 2012 CFR
2012-10-01
... pressure is being restored, the operator of the train shall know that the air brakes function as intended... determined that the brakes on the rear car of the train apply and release in response to air pressure changes... train that has previously received a Class I brake test and that has not been off air for more than four...
49 CFR 232.211 - Class III brake tests-trainline continuity inspection.
Code of Federal Regulations, 2011 CFR
2011-10-01
... pressure is being restored, the operator of the train shall know that the air brakes function as intended... determined that the brakes on the rear car of the train apply and release in response to air pressure changes... train that has previously received a Class I brake test and that has not been off air for more than four...
49 CFR 232.211 - Class III brake tests-trainline continuity inspection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... pressure is being restored, the operator of the train shall know that the air brakes function as intended... determined that the brakes on the rear car of the train apply and release in response to air pressure changes... train that has previously received a Class I brake test and that has not been off air for more than four...
49 CFR 232.211 - Class III brake tests-trainline continuity inspection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... pressure is being restored, the operator of the train shall know that the air brakes function as intended... determined that the brakes on the rear car of the train apply and release in response to air pressure changes... train that has previously received a Class I brake test and that has not been off air for more than four...
49 CFR 232.211 - Class III brake tests-trainline continuity inspection.
Code of Federal Regulations, 2014 CFR
2014-10-01
... pressure is being restored, the operator of the train shall know that the air brakes function as intended... determined that the brakes on the rear car of the train apply and release in response to air pressure changes... train that has previously received a Class I brake test and that has not been off air for more than four...
EDOS operations concept and development approach
NASA Technical Reports Server (NTRS)
Knoble, G.; Garman, C.; Alcott, G.; Ramchandani, C.; Silvers, J.
1994-01-01
The Earth Observing System (EOS) Data and Operations System (EDOS) is being developed by the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) for the capture, level zero processing, distribution, and backup archiving of high speed telemetry data received from EOS spacecraft. All data received will conform to the Consultative Committee for Space Data Standards (CCSDS) recommendations. The major EDOS goals are to: (1) minimize EOS program costs to implement and operate EDOS; (2) respond effectively to EOS growth requirements; and (3) maintain compatibility with existing and enhanced versions of NASA institutional systems required to support EOS spacecraft. In order to meet these goals, the following objectives have been defined for EDOS: (1) standardize EDOS interfaces to maximize utility for future requirements; (2) emphasize life-cycle cost (LCC) considerations (rather than procurement costs) in making design decisions and meeting reliability, maintainability, availability (RMA) and upgradability requirements; (3) implement data-driven operations to the maximum extent possible to minimize staffing requirements and to maximize system responsiveness; (4) provide a system capable of simultaneously supporting multiple spacecraft, each in different phases of their life-cycles; (5) provide for technology insertion features to accommodate growth and future LCC reductions during the operations phase; and (6) provide a system that is sufficiently robust to accommodate incremental performance upgrades while supporting operations. Operations concept working group meetings were facilitated to help develop the EDOS operations concept. This provided a cohesive concept that met with approval of responsible personnel from the start. This approach not only speeded up the development process by reducing review cycles, it also provided a medium for generating good ideas that were immediately molded into feasible concepts. The operations concept was then used as a basis for the EDOS specification. When it was felt that concept elements did not support detailed requirements, the facilitator process was used to resolve discrepancies or to add new concept elements to support the specification. This method provided an ongoing revisal of the operations concept and prevented large revisions at the end of the requirement analysis phase of system development.
Evans, Kris; Rotello, Caren M.; Li, Xingshan; Rayner, Keith
2009-01-01
Cultural differences have been observed in scene perception and memory: Chinese participants purportedly attend to the background information more than did American participants. We investigated the influence of culture by recording eye movements during scene perception and while participants made recognition memory judgements. Real-world pictures with a focal object on a background were shown to both American and Chinese participants while their eye movements were recorded. Later, memory for the focal object in each scene was tested, and the relationship between the focal object (studied, new) and the background context (studied, new) was manipulated. Receiver-operating characteristic (ROC) curves show that both sensitivity and response bias were changed when objects were tested in new contexts. However, neither the decrease in accuracy nor the response bias shift differed with culture. The eye movement patterns were also similar across cultural groups. Both groups made longer and more fixations on the focal objects than on the contexts. The similarity of eye movement patterns and recognition memory behaviour suggests that both Americans and Chinese use the same strategies in scene perception and memory. PMID:18785074
ACIRF user's guide: Theory and examples
NASA Astrophysics Data System (ADS)
Dana, Roger A.
1989-12-01
Design and evaluation of radio frequency systems that must operate through ionospheric disturbances resulting from high altitude nuclear detonations requires an accurate channel model. This model must include the effects of high gain antennas that may be used to receive the signals. Such a model can then be used to construct realizations of the received signal for use in digital simulations of trans-ionospheric links or for use in hardware channel simulators. The FORTRAN channel model ACIRF (Antenna Channel Impulse Response Function) generates random realizations of the impulse response function at the outputs of multiple antennas. This user's guide describes the FORTRAN program ACIRF (version 2.0) that generates realizations of channel impulse response functions at the outputs of multiple antennas with arbitrary beamwidths, pointing angles, and relatives positions. This channel model is valid under strong scattering conditions when Rayleigh fading statistics apply. Both frozen-in and turbulent models for the temporal fluctuations are included in this version of ACIRF. The theory of the channel model is described and several examples are given.
Using convolutional decoding to improve time delay and phase estimation in digital communications
Ormesher, Richard C [Albuquerque, NM; Mason, John J [Albuquerque, NM
2010-01-26
The time delay and/or phase of a communication signal received by a digital communication receiver can be estimated based on a convolutional decoding operation that the communication receiver performs on the received communication signal. If the original transmitted communication signal has been spread according to a spreading operation, a corresponding despreading operation can be integrated into the convolutional decoding operation.
Thermal buffering of receivers for parabolic dish solar thermal power plants
NASA Technical Reports Server (NTRS)
Manvi, R.; Fujita, T.; Gajanana, B. C.; Marcus, C. J.
1980-01-01
A parabolic dish solar thermal power plant comprises a field of parabolic dish power modules where each module is composed of a two-axis tracking parabolic dish concentrator which reflects sunlight (insolation) into the aperture of a cavity receiver at the focal point of the dish. The heat generated by the solar flux entering the receiver is removed by a heat transfer fluid. In the dish power module, this heat is used to drive a small heat engine/generator assembly which is directly connected to the cavity receiver at the focal point. A computer analysis is performed to assess the thermal buffering characteristics of receivers containing sensible and latent heat thermal energy storage. Parametric variations of the thermal inertia of the integrated receiver-buffer storage systems coupled with different fluid flow rate control strategies are carried out to delineate the effect of buffer storage, the transient response of the receiver-storage systems and corresponding fluid outlet temperature. It is concluded that addition of phase change buffer storage will substantially improve system operational characteristics during periods of rapidly fluctuating insolation due to cloud passage.
Detailed requirements document for the Interactive Financial Management System (IFMS), volume 1
NASA Technical Reports Server (NTRS)
Dodson, D. B.
1975-01-01
The detailed requirements for phase 1 (online fund control, subauthorization accounting, and accounts receivable functional capabilities) of the Interactive Financial Management System (IFMS) are described. This includes information on the following: systems requirements, performance requirements, test requirements, and production implementation. Most of the work is centered on systems requirements, and includes discussions on the following processes: resources authority, allotment, primary work authorization, reimbursable order acceptance, purchase request, obligation, cost accrual, cost distribution, disbursement, subauthorization performance, travel, accounts receivable, payroll, property, edit table maintenance, end-of-year, backup input. Other subjects covered include: external systems interfaces, general inquiries, general report requirements, communication requirements, and miscellaneous. Subjects covered under performance requirements include: response time, processing volumes, system reliability, and accuracy. Under test requirements come test data sources, general test approach, and acceptance criteria. Under production implementation come data base establishment, operational stages, and operational requirements.
Predicting significant torso trauma.
Nirula, Ram; Talmor, Daniel; Brasel, Karen
2005-07-01
Identification of motor vehicle crash (MVC) characteristics associated with thoracoabdominal injury would advance the development of automatic crash notification systems (ACNS) by improving triage and response times. Our objective was to determine the relationships between MVC characteristics and thoracoabdominal trauma to develop a torso injury probability model. Drivers involved in crashes from 1993 to 2001 within the National Automotive Sampling System were reviewed. Relationships between torso injury and MVC characteristics were assessed using multivariate logistic regression. Receiver operating characteristic curves were used to compare the model to current ACNS models. There were a total of 56,466 drivers. Age, ejection, braking, avoidance, velocity, restraints, passenger-side impact, rollover, and vehicle weight and type were associated with injury (p < 0.05). The area under the receiver operating characteristic curve (83.9) was significantly greater than current ACNS models. We have developed a thoracoabdominal injury probability model that may improve patient triage when used with ACNS.
Miao, Yi; Yan, Qin; Li, Shuangdi; Li, Bilan; Feng, Youji
2016-06-07
The aim of present study was to investigate the role of preoperative neutrophil to lymphocyte ratio (NLR) and platelet to lymphocyte ratio (PLR) used as prognostic markers for predicting chemotherapeutic response and survival outcomes in patients with epithelial ovarian cancer (EOC) who are receiving platinum-based chemotherapy. A total of 344 patients diagnosed with EOC who are receiving platinum-based chemotherapy from 2005 to 2010 in the hospital were enrolled. NLR and PLR were calculated from complete blood cell count taken before operation. The patients were divided into platinum-resistant (P-R) group and platinum-sensitive (P-S) group according to chemotherapeutic response. Clinicopathologic variables and outcomes were retrospectively collected and compared among groups. We used receiver operating characteristic (ROC) curves to calculate optimal cut-off values for NLR and PLR to predict chemotherapeutic response and prognosis. The AUC, sensitivity, specificity of NLR > 3.02 to predict platinum resistance were 0.819, 75.0% and 81.45%, respectively. The corresponding values of PLR > 207 were 0.727, 60.42% and 85.48%, respectively. Patients with lower value of NLR (NLR < 3.02) or PLR (PLR < 207) had a longer progression-free survival (PFS) and overall survival (OS). In multivariate analysis, NLR and PLR showed a significant association with PFS (hazard ratio [HR], 1.733; 95%CI, 1.225-2.453, P = 0.002 and HR, 1.952; 95%CI, 1.430-2.662, P < 0.001) and OS (HR, 1.616; 95%CI, 1.138-2.297, P = 0.007, and HR, 2.167; 95%CI, 1.565-3.000, P < 0.001). These results suggest that the assessment of NLR and PLR could assist the identification of patients with poor prognosis and had potential clinical value in predicting platinum resistance in patients with EOC.
P10.05 Establishment of team work awake craniotomy: clinical experience in Taiwan
Chen, P.; Chang, W.; Chao, Y.; Toh, C.; Wei, K.
2017-01-01
Abstract Introduction: Awake craniotomy provides the opportunity to maximize both extent of resection and preservation of neurological function. Serial preoperative and postoperative neurobehavial evaluation, magnetic resonance image examination and intraoperative task investigation need multidisciplinary experts to cooperate. Materials and Methods: From 2013, we gradually establish our team for awake craniotomy. Patient who had brain tumor with the symptom of aphasia or hemiparesis and are willing to cooperate would be entered the protocol of awake craniotomy. Patients would receive complete preoperative neurobehavial examination by psychologists and speech therapists and magnetic resonance image included diffuse tensor image. During operation, Patients went through asleep-awake-asleep anesthetic techniques. Direct electric stimulation was used for both cortical and subcortical mapping. Navigation included information of lesion and important fiber tract guided the direction of excision. Rehabilitation doctor performed the tasks and decided the positive response caused by stimulation or excisional procedure. After operation, post-operative image and neurobehavial examination would be performed within one week, 3 months, 6 months and one year later Results: We scheduled awake craniotomy on almost every Tuesday. In recent 89 patients who received awake craniotomy, Twenty-five participants with recurrent tumor underwent the operation. Seven patients received twice and one patient received three times of awake craniotomy. Two patients had controllable intraoperative seizure attack. Early termination of awake status was found in two patients due to general discomfort. Patients with modest preoperative performance status still benefit from the operation. Neurobehavioral functions improved over time and some specific feature correlate to certain aspect of quality of life. The grading of tumor and the extension of resection influence the recovery of neurobehavioral functions and progression free survival considerably. Conclusions: Awake craniotomy is a feasible and effective way to improve not only patient`s survival rate but also quality of life. A team with neurosurgeon, rehabilitation doctor, speech therapist, psychologist, anesthesiologist, nurses and other specialist is important to improve the quality of clinical care for patient who received awake craniotomy. This study is supported by Chang Gung Memorial Hospital with grant number: CMRPG3D0243
Operator assistant to support deep space network link monitor and control
NASA Technical Reports Server (NTRS)
Cooper, Lynne P.; Desai, Rajiv; Martinez, Elmain
1992-01-01
Preparing the Deep Space Network (DSN) stations to support spacecraft missions (referred to as pre-cal, for pre-calibration) is currently an operator and time intensive activity. Operators are responsible for sending and monitoring several hundred operator directivities, messages, and warnings. Operator directives are used to configure and calibrate the various subsystems (antenna, receiver, etc.) necessary to establish a spacecraft link. Messages and warnings are issued by the subsystems upon completion of an operation, changes of status, or an anomalous condition. Some points of pre-cal are logically parallel. Significant time savings could be realized if the existing Link Monitor and Control system (LMC) could support the operator in exploiting the parallelism inherent in pre-cal activities. Currently, operators may work on the individual subsystems in parallel, however, the burden of monitoring these parallel operations resides solely with the operator. Messages, warnings, and directives are all presented as they are received; without being correlated to the event that triggered them. Pre-cal is essentially an overhead activity. During pre-cal, no mission is supported, and no other activity can be performed using the equipment in the link. Therefore, it is highly desirable to reduce pre-cal time as much as possible. One approach to do this, as well as to increase efficiency and reduce errors, is the LMC Operator Assistant (OA). The LMC OA prototype demonstrates an architecture which can be used in concert with the existing LMC to exploit parallelism in pre-cal operations while providing the operators with a true monitoring capability, situational awareness and positive control. This paper presents an overview of the LMC OA architecture and the results from initial prototyping and test activities.
Insertion of operation-and-indicate instructions for optimized SIMD code
Eichenberger, Alexander E; Gara, Alan; Gschwind, Michael K
2013-06-04
Mechanisms are provided for inserting indicated instructions for tracking and indicating exceptions in the execution of vectorized code. A portion of first code is received for compilation. The portion of first code is analyzed to identify non-speculative instructions performing designated non-speculative operations in the first code that are candidates for replacement by replacement operation-and-indicate instructions that perform the designated non-speculative operations and further perform an indication operation for indicating any exception conditions corresponding to special exception values present in vector register inputs to the replacement operation-and-indicate instructions. The replacement is performed and second code is generated based on the replacement of the at least one non-speculative instruction. The data processing system executing the compiled code is configured to store special exception values in vector output registers, in response to a speculative instruction generating an exception condition, without initiating exception handling.
Genetic predisposition scores associate with muscular strength, size, and trainability.
Thomaes, Tom; Thomis, Martine; Onkelinx, Steven; Goetschalckx, Kaatje; Fagard, Robert; Lambrechts, Diether; Vanhees, Luc
2013-08-01
The number of studies trying to identify genetic sequence variation related to muscular phenotypes has increased enormously. The aim of this study was to identify the role of a genetic predisposition score (GPS) based on earlier identified gene variants for different muscular endophenotypes to explain the individual differences in muscular fitness characteristics and the response to training in patients with coronary artery disease. Two hundred and sixty coronary artery disease patients followed a standard ambulatory, 3-month supervised training program for cardiac patients. Maximal knee extension strength (KES) and rectus femoris diameter were measured at baseline and after rehabilitation. Sixty-five single nucleotide polymorphisms (SNP) in 30 genes were selected based on genotype-phenotype association literature. Backward regression analysis revealed subsets of SNP associated with the different phenotypes. GPS were constructed for all sets of SNP by adding up the strength-increasing alleles. General linear models and multiple stepwise regression analysis were used to test the explained variance of the GPS in baseline and strength responses. Receiver operating characteristic curve analyses were performed to discriminate between high- and low-responder status. GPS were significantly associated with the rectus femoris diameter (P < 0.01) and its response (P < 0.0001), the isometric KES (P < 0.05) and its response (P < 0.01), the isokinetic KES at 60° · s (P < 0.05) and 180° · s (P < 0.001) and their responses to training (P < 0.0001), and the isokinetic KES endurance (P < 0.001) and its change after training (P < 0.0001). The GPS was shown as an independent determinant in baseline and response phenotypes with partial explained variance up to 23%. Receiver operating characteristic analysis showed a significant discriminating accuracy of the models, including the GPS for responses to training, with areas under the curve ranging from 0.62 to 0.85. GPS for muscular phenotypes showed to be associated with baseline KES, muscle diameter, and the response to training in cardiac rehabilitation patients.
ERIC Educational Resources Information Center
Starns, Jeffrey J.; Ratcliff, Roger; McKoon, Gail
2012-01-01
We tested two explanations for why the slope of the z-transformed receiver operating characteristic (zROC) is less than 1 in recognition memory: the unequal-variance account (target evidence is more variable than lure evidence) and the dual-process account (responding reflects both a continuous familiarity process and a threshold recollection…
ERIC Educational Resources Information Center
Mackenzie, Catherine; Paton, Gillian; Kelly, Shona; Brady, Marian; Muir, Margaret
2012-01-01
Background: The broad life implications of acquired dysarthria are recognized, but they have received little attention in stroke management. Reports of group therapy, which may be a suitable approach to intervention, are not available for stroke-related dysarthria. Aims: To examine the operational feasibility of and response to a new eight-session…
75 FR 22724 - Drawbridge Operation Regulation; Chambers Creek, Steilacoom, WA, Schedule Change
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-30
... which two-hour notice would have been required for openings from 3:30 p.m. to 7 a.m. every day. The NPRM.... The primary point of objection was that 3:30 p.m. was too early in the day, especially in summer... the end of a day of boating. The Coast Guard received a total of 17 written responses. At least seven...
NASA Astrophysics Data System (ADS)
Smith, J. Torquil; Morrison, H. Frank; Doolittle, Lawrence R.; Tseng, Hung-Wen
2007-03-01
Equivalent dipole polarizabilities are a succinct way to summarize the inductive response of an isolated conductive body at distances greater than the scale of the body. Their estimation requires measurement of secondary magnetic fields due to currents induced in the body by time varying magnetic fields in at least three linearly independent (e.g., orthogonal) directions. Secondary fields due to an object are typically orders of magnitude smaller than the primary inducing fields near the primary field sources (transmitters). Receiver coils may be oriented orthogonal to primary fields from one or two transmitters, nulling their response to those fields, but simultaneously nulling to fields of additional transmitters is problematic. If transmitter coils are constructed symmetrically with respect to inversion in a point, their magnetic fields are symmetric with respect to that point. If receiver coils are operated in pairs symmetric with respect to inversion in the same point, then their differenced output is insensitive to the primary fields of any symmetrically constructed transmitters, allowing nulling to three (or more) transmitters. With a sufficient number of receivers pairs, object equivalent dipole polarizabilities can be estimated in situ from measurements at a single instrument sitting, eliminating effects of inaccurate instrument location on polarizability estimates. The method is illustrated with data from a multi-transmitter multi-receiver system with primary field nulling through differenced receiver pairs, interpreted in terms of principal equivalent dipole polarizabilities as a function of time.
Wogar, M A; Bradshaw, C M; Szabadi, E
1991-01-01
The possible involvement of the ascending 5-hydroxytryptaminergic (5HTergic) pathways in the maintenance of operant behaviour by positive reinforcement was examined using a quantitative paradigm based on Herrnstein's (1970) equation which defines a hyperbolic relationship between steady-state response rate and reinforcement frequency in variable-interval schedules. Nine rats received injections of 5,7-dihydroxytryptamine into the dorsal and median raphe nuclei; 12 rats received sham injections. The rats were trained to steady-state in a series of variable-interval schedules of sucrose reinforcement affording a range of reinforcement frequencies. Herrnstein's equation was fitted to the data obtained from each rat and to the averaged data obtained from the two groups. The value of KH (the parameter expressing the reinforcement frequency needed to obtain the half-maximum response rate) was significantly lower in the lesioned group than in the control group; the values of Rmax (the parameter expressing the maximum response rate) did not differ significantly between the two groups. The levels of 5HT and 5-hydroxyindoleacetic acid in the parietal cortex, hippocampus, nucleus accumbens and hypothalamus were markedly reduced in all four regions in the lesioned group, but the levels of noradrenaline and dopamine were not significantly affected. The results indicate that damage to the central 5HTergic pathways resulted in an increase in the "value" of the sucrose reinforcer, without affecting the animals' response capacity. The results are consistent with the suggestion that the 5HTergic pathways may exert some limiting control on the "values" of certain reinforcers.
Jackknife variance of the partial area under the empirical receiver operating characteristic curve.
Bandos, Andriy I; Guo, Ben; Gur, David
2017-04-01
Receiver operating characteristic analysis provides an important methodology for assessing traditional (e.g., imaging technologies and clinical practices) and new (e.g., genomic studies, biomarker development) diagnostic problems. The area under the clinically/practically relevant part of the receiver operating characteristic curve (partial area or partial area under the receiver operating characteristic curve) is an important performance index summarizing diagnostic accuracy at multiple operating points (decision thresholds) that are relevant to actual clinical practice. A robust estimate of the partial area under the receiver operating characteristic curve is provided by the area under the corresponding part of the empirical receiver operating characteristic curve. We derive a closed-form expression for the jackknife variance of the partial area under the empirical receiver operating characteristic curve. Using the derived analytical expression, we investigate the differences between the jackknife variance and a conventional variance estimator. The relative properties in finite samples are demonstrated in a simulation study. The developed formula enables an easy way to estimate the variance of the empirical partial area under the receiver operating characteristic curve, thereby substantially reducing the computation burden, and provides important insight into the structure of the variability. We demonstrate that when compared with the conventional approach, the jackknife variance has substantially smaller bias, and leads to a more appropriate type I error rate of the Wald-type test. The use of the jackknife variance is illustrated in the analysis of a data set from a diagnostic imaging study.
NASA Technical Reports Server (NTRS)
1981-01-01
This phase consists of the engineering design, fabrication, assembly, operation, economic analysis, and process support R&D for an Experimental Process System Development Unit (EPSDU). The mechanical bid package was issued and the bid responses are under evaluation. Similarly, the electrical bid package was issued, however, responses are not yet due. The majority of all equipment is on order or has been received at the EPSDU site. The pyrolysis/consolidation process design package was issued. Preparation of process and instrumentation diagram for the free-space reactor was started. In the area of melting/consolidation, Kayex successfully melted chunk silicon and have produced silicon shot. The free-space reactor powder was successfully transported pneumatically from a storage bin to the auger feeder twenty-five feet up and was melted. The fluid-bed PDU has successfully operated at silane feed concentrations up to 21%. The writing of the operating manual has started. Overall, the design phase is nearing completion.
Method and apparatus for determining position using global positioning satellites
NASA Technical Reports Server (NTRS)
Ward, John (Inventor); Ward, William S. (Inventor)
1998-01-01
A global positioning satellite receiver having an antenna for receiving a L1 signal from a satellite. The L1 signal is processed by a preamplifier stage including a band pass filter and a low noise amplifier and output as a radio frequency (RF) signal. A mixer receives and de-spreads the RF signal in response to a pseudo-random noise code, i.e., Gold code, generated by an internal pseudo-random noise code generator. A microprocessor enters a code tracking loop, such that during the code tracking loop, it addresses the pseudo-random code generator to cause the pseudo-random code generator to sequentially output pseudo-random codes corresponding to satellite codes used to spread the L1 signal, until correlation occurs. When an output of the mixer is indicative of the occurrence of correlation between the RF signal and the generated pseudo-random codes, the microprocessor enters an operational state which slows the receiver code sequence to stay locked with the satellite code sequence. The output of the mixer is provided to a detector which, in turn, controls certain routines of the microprocessor. The microprocessor will output pseudo range information according to an interrupt routine in response detection of correlation. The pseudo range information is to be telemetered to a ground station which determines the position of the global positioning satellite receiver.
Direct memory access transfer completion notification
Archer, Charles J. , Blocksome; Michael A. , Parker; Jeffrey, J [Rochester, MN
2011-02-15
Methods, systems, and products are disclosed for DMA transfer completion notification that include: inserting, by an origin DMA on an origin node in an origin injection FIFO, a data descriptor for an application message; inserting, by the origin DMA, a reflection descriptor in the origin injection FIFO, the reflection descriptor specifying a remote get operation for injecting a completion notification descriptor in a reflection injection FIFO on a reflection node; transferring, by the origin DMA to a target node, the message in dependence upon the data descriptor; in response to completing the message transfer, transferring, by the origin DMA to the reflection node, the completion notification descriptor in dependence upon the reflection descriptor; receiving, by the origin DMA from the reflection node, a completion packet; and notifying, by the origin DMA in response to receiving the completion packet, the origin node's processing core that the message transfer is complete.
System and technique for ultrasonic characterization of settling suspensions
Greenwood, Margaret S [Richland, WA; Panetta, Paul D [Richland, WA; Bamberger, Judith A [Richland, WA; Pappas, Richard A [Richland, WA
2006-11-28
A system for determining properties of settling suspensions includes a settling container, a mixer, and devices for ultrasonic interrogation transverse to the settling direction. A computer system controls operation of the mixer and the interrogation devices and records the response to the interrogating as a function of settling time, which is then used to determine suspension properties. Attenuation versus settling time for dilute suspensions, such as dilute wood pulp suspension, exhibits a peak at different settling times for suspensions having different properties, and the location of this peak is used as one mechanism for characterizing suspensions. Alternatively or in addition, a plurality of ultrasound receivers are arranged at different angles to a common transmitter to receive scattering responses at a variety of angles during particle settling. Angular differences in scattering as a function of settling time are also used to characterize the suspension.
Receiver psychology turns 20: is it time for a broader approach?
Miller, Cory T.; Bee, Mark A.
2013-01-01
Twenty years ago, a new conceptual paradigm known as ‘receiver psychology’ was introduced to explain the evolution of animal communication systems. This paradigm advanced the idea that psychological processes in the receiver's nervous system influence a signal's detectability, discriminability and memorability, and thereby serve as powerful sources of selection shaping signal design. While advancing our understanding of signal diversity, more recent studies make clear that receiver psychology, as a paradigm, has been structured too narrowly and does not incorporate many of the perceptual and cognitive processes of signal reception that operate between sensory transduction and a receiver's response. Consequently, the past two decades of research on receiver psychology have emphasized considerations of signal evolution but failed to ask key questions about the mechanisms of signal reception and their evolution. The primary aim of this essay is to advocate for a broader receiver psychology paradigm that more explicitly includes a research focus on receivers' psychological landscapes. We review recent experimental studies of hearing and sound communication to illustrate how considerations of several general perceptual and cognitive processes will facilitate future research on animal signalling systems. We also emphasize how a rigorous comparative approach to receiver psychology is critical to explicating the full range of perceptual and cognitive processes involved in receiving and responding to signals. PMID:24013277
Communications During Critical Mission Operations: Preparing for InSight's Landing on Mars
NASA Technical Reports Server (NTRS)
Asmar, Sami; Oudrhiri, Kamal; Kurtik, Susan; Weinstein-Weiss, Stacy
2014-01-01
Radio communications with deep space missions are often taken for granted due to the impressively successful records since, for decades, the technology and infrastructure have been developed for ground and flight systems to optimize telemetry and commanding. During mission-critical events such as the entry, descent, and landing of a spacecraft on the surface of Mars, the signal's level and frequency dynamics vary significantly and typically exceed the threshold of the budgeted links. The challenge is increased when spacecraft shed antennas with heat shields and other hardware during those risky few minutes. We have in the past successfully received signals on Earth during critical events even ones not intended for ground reception. These included the UHF signal transmitted by Curiosity to Marsorbiting assets. Since NASA's Deep Space Network does not operate in the UHF band, large radio telescopes around the world are utilized. The Australian CSIRO Parkes Radio Telescope supported the Curiosity UHF signal reception and DSN receivers, tools, and expertise were used in the process. In preparation for the InSight mission's landing on Mars in 2016, preparations are underway to support the UHF communications. This paper presents communication scenarios with radio telescopes, and the DSN receiver and tools. It also discusses the usefulness of the real-time information content for better response time by the mission team towards successful mission operations.
Parallel-Processing Equalizers for Multi-Gbps Communications
NASA Technical Reports Server (NTRS)
Gray, Andrew; Ghuman, Parminder; Hoy, Scott; Satorius, Edgar H.
2004-01-01
Architectures have been proposed for the design of frequency-domain least-mean-square complex equalizers that would be integral parts of parallel- processing digital receivers of multi-gigahertz radio signals and other quadrature-phase-shift-keying (QPSK) or 16-quadrature-amplitude-modulation (16-QAM) of data signals at rates of multiple gigabits per second. Equalizers as used here denotes receiver subsystems that compensate for distortions in the phase and frequency responses of the broad-band radio-frequency channels typically used to convey such signals. The proposed architectures are suitable for realization in very-large-scale integrated (VLSI) circuitry and, in particular, complementary metal oxide semiconductor (CMOS) application- specific integrated circuits (ASICs) operating at frequencies lower than modulation symbol rates. A digital receiver of the type to which the proposed architecture applies (see Figure 1) would include an analog-to-digital converter (A/D) operating at a rate, fs, of 4 samples per symbol period. To obtain the high speed necessary for sampling, the A/D and a 1:16 demultiplexer immediately following it would be constructed as GaAs integrated circuits. The parallel-processing circuitry downstream of the demultiplexer, including a demodulator followed by an equalizer, would operate at a rate of only fs/16 (in other words, at 1/4 of the symbol rate). The output from the equalizer would be four parallel streams of in-phase (I) and quadrature (Q) samples.
Martínez-Camblor, Pablo; Pardo-Fernández, Juan C
2017-01-01
Diagnostic procedures are based on establishing certain conditions and then checking if those conditions are satisfied by a given individual. When the diagnostic procedure is based on a continuous marker, this is equivalent to fix a region or classification subset and then check if the observed value of the marker belongs to that region. Receiver operating characteristic curve is a valuable and popular tool to study and compare the diagnostic ability of a given marker. Besides, the area under the receiver operating characteristic curve is frequently used as an index of the global discrimination ability. This paper revises and widens the scope of the receiver operating characteristic curve definition by setting the classification subsets in which the final decision is based in the spotlight of the analysis. We revise the definition of the receiver operating characteristic curve in terms of particular classes of classification subsets and then focus on a receiver operating characteristic curve generalization for situations in which both low and high values of the marker are associated with more probability of having the studied characteristic. Parametric and non-parametric estimators of the receiver operating characteristic curve generalization are investigated. Monte Carlo studies and real data examples illustrate their practical performance.
Evaluating the Validity Indices of the Personality Assessment Inventory-Adolescent Version.
Meyer, Justin K; Hong, Sang-Hwang; Morey, Leslie C
2015-08-01
Past research has established strong psychometric properties of several indicators of response distortion on the Personality Assessment Inventory (PAI). However, to date, it has been unclear whether the response distortion indicators of the adolescent version of the PAI (PAI-A) operate in an equally valid manner. The current study sought to examine several response distortion indicators on the PAI-A to determine their relative efficacy at the detection of distorted responding, including both positive distortion and negative distortion. Protocols of 98 college students asked to either overreport or underreport were compared with 98 age-matched individuals sampled from the clinical standardization sample and the community standardization sample, respectively. Comparisons between groups were accomplished through the examination of effect sizes and receiver operating characteristic curves. All indicators demonstrated the ability to distinguish between actual and feigned responding, including several newly developed indicators. This study provides support for the ability of distortion indicators developed for the PAI to also function appropriately on the PAI-A. © The Author(s) 2014.
Yin, J Y; Ho, K M
2012-07-01
This systematic review and meta-analysis assessed the accuracy of plethysmographic variability index derived from the Massimo(®) pulse oximeter to predict preload responsiveness in peri-operative and critically ill patients. A total of 10 studies were retrieved from the literature, involving 328 patients who met the selection criteria. Overall, the diagnostic odds ratio (16.0; 95% CI 5-48) and area under the summary receiver operating characteristic curve (0.87; 95% CI 0.78-0.95) for plethysmographic variability index to predict fluid or preload responsiveness was very good, but significant heterogeneity existed. This could be explained by a lower accuracy of plethysmographic variability index in spontaneously breathing or paediatric patients and those studies that used pre-load challenges other than colloid fluid. The results indicate specific directions for future studies. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.
Smooth time-dependent receiver operating characteristic curve estimators.
Martínez-Camblor, Pablo; Pardo-Fernández, Juan Carlos
2018-03-01
The receiver operating characteristic curve is a popular graphical method often used to study the diagnostic capacity of continuous (bio)markers. When the considered outcome is a time-dependent variable, two main extensions have been proposed: the cumulative/dynamic receiver operating characteristic curve and the incident/dynamic receiver operating characteristic curve. In both cases, the main problem for developing appropriate estimators is the estimation of the joint distribution of the variables time-to-event and marker. As usual, different approximations lead to different estimators. In this article, the authors explore the use of a bivariate kernel density estimator which accounts for censored observations in the sample and produces smooth estimators of the time-dependent receiver operating characteristic curves. The performance of the resulting cumulative/dynamic and incident/dynamic receiver operating characteristic curves is studied by means of Monte Carlo simulations. Additionally, the influence of the choice of the required smoothing parameters is explored. Finally, two real-applications are considered. An R package is also provided as a complement to this article.
O'Brien, Lisa; McKeough, Carly; Abbasi, Randa
2013-12-01
Multidisciplinary pre-admission patient education is commonly recommended for elective surgery patients, and may involve the provision of written information and presentations from the health team. However, the occupational therapy role with elective sternotomy patients in our setting is confined to the post-operative period. We aimed to evaluate cardiac surgery patients' perception of the effectiveness and timing of pre-admission multidisciplinary written information and post-operative verbal education provided by occupational therapy. This cross-sectional study involved a written survey, which was posted to 375 people who had undergone cardiac surgery in 2009-2010. Questions were designed to elicit patient perceptions of both pre-operative written information and post-operative education relating to post-operative precautions and return to activity received from occupational therapy. There were 118 surveys returned equalling a 31.4% response rate. Eighty-nine per cent of respondents recalled receiving and reading the pre-surgery information booklet, and this was significantly correlated with feeling prepared for the post-operative experience and adherence with precautions (P < 0.0001). Exactly 30.4% of respondents stated that they experienced stress and anxiety in relation to post-operative expectations, and 47.3% felt the information provided in the occupational therapy education sessions would have been more beneficial for their understanding and coping if provided prior to surgery. Multidisciplinary written pre-surgery education appears to be providing patients with a good understanding of what to expect following surgery. The results suggest that pre-operative verbal education from occupational therapy would assist in reducing anxiety in a subgroup of patients. © 2013 Occupational Therapy Australia.
System and method for quench protection of a superconductor
Huang, Xianrui; Sivasubramaniam, Kiruba Haran; Bray, James William; Ryan, David Thomas
2008-03-11
A system and method for protecting a superconductor from a quench condition. A quench protection system is provided to protect the superconductor from damage due to a quench condition. The quench protection system comprises a voltage detector operable to detect voltage across the superconductor. The system also comprises a frequency filter coupled to the voltage detector. The frequency filter is operable to couple voltage signals to a control circuit that are representative of a rise in superconductor voltage caused by a quench condition and to block voltage signals that are not. The system is operable to detect whether a quench condition exists in the superconductor based on the voltage signal received via the frequency filter and to initiate a protective action in response.
Room-temperature nine-µm-wavelength photodetectors and GHz-frequency heterodyne receivers.
Palaferri, Daniele; Todorov, Yanko; Bigioli, Azzurra; Mottaghizadeh, Alireza; Gacemi, Djamal; Calabrese, Allegra; Vasanelli, Angela; Li, Lianhe; Davies, A Giles; Linfield, Edmund H; Kapsalidis, Filippos; Beck, Mattias; Faist, Jérôme; Sirtori, Carlo
2018-04-05
Room-temperature operation is essential for any optoelectronics technology that aims to provide low-cost, compact systems for widespread applications. A recent technological advance in this direction is bolometric detection for thermal imaging, which has achieved relatively high sensitivity and video rates (about 60 hertz) at room temperature. However, owing to thermally induced dark current, room-temperature operation is still a great challenge for semiconductor photodetectors targeting the wavelength band between 8 and 12 micrometres, and all relevant applications, such as imaging, environmental remote sensing and laser-based free-space communication, have been realized at low temperatures. For these devices, high sensitivity and high speed have never been compatible with high-temperature operation. Here we show that a long-wavelength (nine micrometres) infrared quantum-well photodetector fabricated from a metamaterial made of sub-wavelength metallic resonators exhibits strongly enhanced performance with respect to the state of the art up to room temperature. This occurs because the photonic collection area of each resonator is much larger than its electrical area, thus substantially reducing the dark current of the device. Furthermore, we show that our photonic architecture overcomes intrinsic limitations of the material, such as the drop of the electronic drift velocity with temperature, which constrains conventional geometries at cryogenic operation. Finally, the reduced physical area of the device and its increased responsivity allow us to take advantage of the intrinsic high-frequency response of the quantum detector at room temperature. By mixing the frequencies of two quantum-cascade lasers on the detector, which acts as a heterodyne receiver, we have measured a high-frequency signal, above four gigahertz (GHz). Therefore, these wide-band uncooled detectors could benefit technologies such as high-speed (gigabits per second) multichannel coherent data transfer and high-precision molecular spectroscopy.
Room-temperature nine-µm-wavelength photodetectors and GHz-frequency heterodyne receivers
NASA Astrophysics Data System (ADS)
Palaferri, Daniele; Todorov, Yanko; Bigioli, Azzurra; Mottaghizadeh, Alireza; Gacemi, Djamal; Calabrese, Allegra; Vasanelli, Angela; Li, Lianhe; Davies, A. Giles; Linfield, Edmund H.; Kapsalidis, Filippos; Beck, Mattias; Faist, Jérôme; Sirtori, Carlo
2018-04-01
Room-temperature operation is essential for any optoelectronics technology that aims to provide low-cost, compact systems for widespread applications. A recent technological advance in this direction is bolometric detection for thermal imaging, which has achieved relatively high sensitivity and video rates (about 60 hertz) at room temperature. However, owing to thermally induced dark current, room-temperature operation is still a great challenge for semiconductor photodetectors targeting the wavelength band between 8 and 12 micrometres, and all relevant applications, such as imaging, environmental remote sensing and laser-based free-space communication, have been realized at low temperatures. For these devices, high sensitivity and high speed have never been compatible with high-temperature operation. Here we show that a long-wavelength (nine micrometres) infrared quantum-well photodetector fabricated from a metamaterial made of sub-wavelength metallic resonators exhibits strongly enhanced performance with respect to the state of the art up to room temperature. This occurs because the photonic collection area of each resonator is much larger than its electrical area, thus substantially reducing the dark current of the device. Furthermore, we show that our photonic architecture overcomes intrinsic limitations of the material, such as the drop of the electronic drift velocity with temperature, which constrains conventional geometries at cryogenic operation. Finally, the reduced physical area of the device and its increased responsivity allow us to take advantage of the intrinsic high-frequency response of the quantum detector at room temperature. By mixing the frequencies of two quantum-cascade lasers on the detector, which acts as a heterodyne receiver, we have measured a high-frequency signal, above four gigahertz (GHz). Therefore, these wide-band uncooled detectors could benefit technologies such as high-speed (gigabits per second) multichannel coherent data transfer and high-precision molecular spectroscopy.
Ripple gate drive circuit for fast operation of series connected IGBTs
Rockot, Joseph H.; Murray, Thomas W.; Bass, Kevin C.
2005-09-20
A ripple gate drive circuit includes a plurality of transistors having their power terminals connected in series across an electrical potential. A plurality of control circuits, each associated with one of the transistors, is provided. Each control circuit is responsive to a control signal and an optical signal received from at least one other control circuit for controlling the conduction of electrical current through the power terminals of the associated transistor. The control circuits are responsive to a first state of the control circuit for causing each transistor in series to turn on sequentially and responsive to a second state of the control signal for causing each transistor in series to turn off sequentially.
Agarwal, Prateek; Pierce, John; Welch, William C
2016-05-01
Lumbar spine surgery can be performed using various anesthetic modalities, most notably general or spinal anesthesia. Because data comparing the cost of these anesthetic modalities in spine surgery are scarce, this study asks whether spinal anesthesia is less costly than general anesthesia. A total of 542 patients who underwent elective lumbar diskectomy or laminectomy spine surgery between 2007 and 2011 were retrospectively identified, with 364 having received spinal anesthesia and 178 having received general anesthesia. Mean direct operating cost, indirect cost (general support staff, insurance, taxes, floor space, facility, and administrative costs), and total cost were compared among patients who received general and spinal anesthesia. Linear multiple regression analysis was used to identify the effect of anesthesia type on cost and determine the factors underlying this effect, while controlling for patient and procedure characteristics. When controlling for patient and procedure characteristics, use of spinal anesthesia was associated with a 41.1% lower direct operating cost (-$3629 ± $343, P < 0.001), 36.6% lower indirect cost (-$1603 ± $168, P < 0.001), and 39.6% lower total cost (-$5232 ± $482, P < 0.001) compared with general anesthesia. Shorter hospital stay, shorter duration of anesthesia, shorter duration of operation, and lower estimated blood loss contributed to lower costs for spinal anesthesia, but other factors beyond these were also responsible for lower direct operating and total costs. When comparing the benefits of spinal and general anesthesia, spinal anesthesia is less costly when used in patients undergoing lumbar diskectomy and laminectomy spine surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
Partitioned key-value store with atomic memory operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bent, John M.; Faibish, Sorin; Grider, Gary
A partitioned key-value store is provided that supports atomic memory operations. A server performs a memory operation in a partitioned key-value store by receiving a request from an application for at least one atomic memory operation, the atomic memory operation comprising a memory address identifier; and, in response to the atomic memory operation, performing one or more of (i) reading a client-side memory location identified by the memory address identifier and storing one or more key-value pairs from the client-side memory location in a local key-value store of the server; and (ii) obtaining one or more key-value pairs from themore » local key-value store of the server and writing the obtained one or more key-value pairs into the client-side memory location identified by the memory address identifier. The server can perform functions obtained from a client-side memory location and return a result to the client using one or more of the atomic memory operations.« less
Complex Dynamic Processes in Sign Tracking With an Omission Contingency (Negative Automaintenance)
Killeen, Peter R.
2008-01-01
Hungry pigeons received food periodically, signaled by the onset of a keylight. Key pecks aborted the feeding. Subjects responded for thousands of trials, despite the contingent nonreinforcement, with varying probability as the intertrial interval was varied. Hazard functions showed the dominant tendency to be perseveration in responding and not responding. Once perseveration was accounted for, a linear operator model of associative conditioning further improved predictions. Response rates during trials were correlated with the prior probabilities of a response. Rescaled range analyses showed that the behavioral trajectories were a kind of fractional Brownian motion. PMID:12561133
Complex dynamic processes in sign tracking with an omission contingency (negative automaintenance).
Killeen, Peter R
2003-01-01
Hungry pigeons received food periodically, signaled by the onset of a keylight. Key pecks aborted the feeding. Subjects responded for thousands of trials, despite the contingent nonreinforcement, with varying probability as the intertrial interval was varied. Hazard functions showed the dominant tendency to be perseveration in responding and not responding. Once perseveration was accounted for, a linear operator model of associative conditioning further improved predictions. Response rates during trials were correlated with the prior probabilities of a response. Rescaled range analyses showed that the behavioral trajectories were a kind of fractional Brownian motion.
Haydari, Mohammad Reza; Panjeshahin, Mohammad Reza; Mashghoolozekr, Elaheh; Nekooeian, Ali Akbar
2017-01-01
Background: Hawthorn species decreases blood pressure and relaxes precontracted vessels. This study aimed at examining the antihypertensive effect and related mechanisms of hydroalcoholic extract of Crataegus azarolus subspecies aronia fruit in rats with renovascular hypertension. Methods: Six groups of male Sprague-Dawley rats, each containing 6 to 8 rats, were studied. The groups comprised of one sham group and 5 renal artery-clipped groups. The sham group received vehicle (distilled water 0.5 ml/day) and the renal artery-clipped groups received vehicle or the extract at 5, 10, 20 or 30 mg/kg/day. Oral vehicle or extract was administered daily for 4 weeks following sham-operation or induction of hypertension. Systolic blood pressure and heart rate were measured weekly. Isolated aorta study was performed by last week and serum superoxide dismutase and glutathione reductase were measured. The findings were analyzed using one-way analysis of variance and Duncan’s multiple range tests at P≤0.05 using SigmaStat software. Results: The data obtained after 4 weeks of treatment showed that the renal artery-clipped group receiving vehicle had significantly higher systolic blood pressure (P=0.002) and phenylephrine maximal response (P=0.01); and lower acetylcholine maximal response (P=0.01), serum superoxide dismutase (P=0.006) and serum glutathione reductase (P=0.006) than those of the sham group. The renal artery-clipped group receiving extract had significantly lower systolic blood pressure (P=0.03) and phenylephrine maximal response (P=0.01); and significantly higher acetylcholine maximal response (P=0.01), serum superoxide dismutase (P=0.015), and serum glutathione reductase (P=0.015) than those of the renal artery-clipped group receiving vehicle. Conclusion: Our findings show that the hydroalcoholic extract of Crataegus azarolus subspecies aronia fruit has antihypertensive effects, which may be partly due to antioxidant and nitric oxide releasing effects. PMID:28533575
Haydari, Mohammad Reza; Panjeshahin, Mohammad Reza; Mashghoolozekr, Elaheh; Nekooeian, Ali Akbar
2017-05-01
Hawthorn species decreases blood pressure and relaxes precontracted vessels. This study aimed at examining the antihypertensive effect and related mechanisms of hydroalcoholic extract of Crataegus azarolus subspecies aronia fruit in rats with renovascular hypertension. Six groups of male Sprague-Dawley rats, each containing 6 to 8 rats, were studied. The groups comprised of one sham group and 5 renal artery-clipped groups. The sham group received vehicle (distilled water 0.5 ml/day) and the renal artery-clipped groups received vehicle or the extract at 5, 10, 20 or 30 mg/kg/day. Oral vehicle or extract was administered daily for 4 weeks following sham-operation or induction of hypertension. Systolic blood pressure and heart rate were measured weekly. Isolated aorta study was performed by last week and serum superoxide dismutase and glutathione reductase were measured. The findings were analyzed using one-way analysis of variance and Duncan's multiple range tests at P≤0.05 using SigmaStat software. The data obtained after 4 weeks of treatment showed that the renal artery-clipped group receiving vehicle had significantly higher systolic blood pressure (P=0.002) and phenylephrine maximal response (P=0.01); and lower acetylcholine maximal response (P=0.01), serum superoxide dismutase (P=0.006) and serum glutathione reductase (P=0.006) than those of the sham group. The renal artery-clipped group receiving extract had significantly lower systolic blood pressure (P=0.03) and phenylephrine maximal response (P=0.01); and significantly higher acetylcholine maximal response (P=0.01), serum superoxide dismutase (P=0.015), and serum glutathione reductase (P=0.015) than those of the renal artery-clipped group receiving vehicle. Our findings show that the hydroalcoholic extract of Crataegus azarolus subspecies aronia fruit has antihypertensive effects, which may be partly due to antioxidant and nitric oxide releasing effects.
Pagani, Olivia; Gelber, Shari; Simoncini, Edda; Castiglione-Gertsch, Monica; Price, Karen N; Gelber, Richard D; Holmberg, Stig B; Crivellari, Diana; Collins, John; Lindtner, Jurij; Thürlimann, Beat; Fey, Martin F; Murray, Elizabeth; Forbes, John F; Coates, Alan S; Goldhirsch, Aron
2009-08-01
To compare the efficacy of chemoendocrine treatment with that of endocrine treatment (ET) alone for postmenopausal women with highly endocrine responsive breast cancer. In the International Breast Cancer Study Group (IBCSG) Trials VII and 12-93, postmenopausal women with node-positive, estrogen receptor (ER)-positive or ER-negative, operable breast cancer were randomized to receive either chemotherapy or endocrine therapy or combined chemoendocrine treatment. Results were analyzed overall in the cohort of 893 patients with endocrine-responsive disease, and according to prospectively defined categories of ER, age and nodal status. STEPP analyses assessed chemotherapy effect. The median follow-up was 13 years. Adding chemotherapy reduced the relative risk of a disease-free survival event by 19% (P = 0.02) compared with ET alone. STEPP analyses showed little effect of chemotherapy for tumors with high levels of ER expression (P = 0.07), or for the cohort with one positive node (P = 0.03). Chemotherapy significantly improves disease-free survival for postmenopausal women with endocrine-responsive breast cancer, but the magnitude of the effect is substantially attenuated if ER levels are high.
Information and communication technology in disease surveillance, India: a case study
2010-01-01
India has made appreciable progress and continues to demonstrate a strong commitment for establishing and operating a disease surveillance programme responsive to the requirements of the International Health Regulations (IHR[2005]). Within five years of its launch, India has effectively used modern information and communication technology for collection, storage, transmission and management of data related to disease surveillance and effective response. Terrestrial and/or satellite based linkages are being established within all states, districts, state-run medical colleges, infectious disease hospitals, and public health laboratories. This network enables speedy data transfer, video conferencing, training and e-learning for outbreaks and programme monitoring. A 24x7 call centre is in operation to receive disease alerts. To complement these efforts, a media scanning and verification cell functions to receive reports of early warning signals. During the 2009 H1N1 outbreak, the usefulness of the information and communication technology (ICT) network was well appreciated. India is using ICT as part of its Integrated Disease Surveillance Project (IDSP) to help overcome the challenges in further expansion in hard-to-reach populations, to increase the involvement of the private sector, and to increase the use of other modes of communication like e-mail and voicemail. PMID:21143821
Autoshaping and automaintenance: a neural-network approach.
Burgos, José E
2007-07-01
This article presents an interpretation of autoshaping, and positive and negative automaintenance, based on a neural-network model. The model makes no distinction between operant and respondent learning mechanisms, and takes into account knowledge of hippocampal and dopaminergic systems. Four simulations were run, each one using an A-B-A design and four instances of feedfoward architectures. In A, networks received a positive contingency between inputs that simulated a conditioned stimulus (CS) and an input that simulated an unconditioned stimulus (US). Responding was simulated as an output activation that was neither elicited by nor required for the US. B was an omission-training procedure. Response directedness was defined as sensory feedback from responding, simulated as a dependence of other inputs on responding. In Simulation 1, the phenomena were simulated with a fully connected architecture and maximally intense response feedback. The other simulations used a partially connected architecture without competition between CS and response feedback. In Simulation 2, a maximally intense feedback resulted in substantial autoshaping and automaintenance. In Simulation 3, eliminating response feedback interfered substantially with autoshaping and automaintenance. In Simulation 4, intermediate autoshaping and automaintenance resulted from an intermediate response feedback. Implications for the operant-respondent distinction and the behavior-neuroscience relation are discussed.
Send-side matching of data communications messages
Archer, Charles J.; Blocksome, Michael A.; Ratterman, Joseph D.; Smith, Brian E.
2014-07-01
Send-side matching of data communications messages includes a plurality of compute nodes organized for collective operations, including: issuing by a receiving node to source nodes a receive message that specifies receipt of a single message to be sent from any source node, the receive message including message matching information, a specification of a hardware-level mutual exclusion device, and an identification of a receive buffer; matching by two or more of the source nodes the receive message with pending send messages in the two or more source nodes; operating by one of the source nodes having a matching send message the mutual exclusion device, excluding messages from other source nodes with matching send messages and identifying to the receiving node the source node operating the mutual exclusion device; and sending to the receiving node from the source node operating the mutual exclusion device a matched pending message.
Xiao-ting, Wang; Hua, Zhao; Da-wei, Liu; Hong-min, Zhang; Huai-wu, He; Yun, Long; Wen-zhao, Chai
2015-10-01
The objective is to explore the value of end-tidal carbon dioxide (ETCO2) in replacing cardiac index for evaluating fluid responsiveness during the passive leg raising (PLR) test and mini-fluid challenge (mini-FC). Patients experiencing septic shock and who were on mechanical ventilation in an intensive care unit were divided into responder and nonresponder groups according to whether their cardiac index increased by more than 10% after the FC. Before and after those tests, the changes in ETCO2, central venous pressure, heart rate, mean arterial pressure, pulse pressure, and cardiac output were recorded. Of the 48 patients in the study, 34 had fluid responsiveness according to the changes in cardiac output or stroke volume. The ΔCI and ΔETCO2 in the responder group were larger than the changes in the nonresponder group during the PLR test (1.1 ± 0.7 vs 0.2 ± 0.4 L/min per square meter, 3.0 ± 3.0 vs 0.5 ± 2.5 mm Hg; P < .05) but not during mini-FC. ΔETCO2 greater than or equal to 5% during the PLR test predicted fluid responsiveness with 93.4% specificity and 75.8% sensitivity in a receiver operating characteristic curve. The area under the curve was 0.849 (95% confidence interval, 0.739-0.930). ΔETCO2 greater than or equal to 3% during the mini-FC predicted fluid responsiveness with 93.4% specificity and 33.3% sensitivity in a receiver operating characteristic curve, and the area under the curve was 0.781 (95% confidence interval, 0.646-0.915). The changes in ETCO2 may predict fluid responsiveness during the PLR test in patients with septic shock, but similar results were not found with the mini-FC. Copyright © 2015 Elsevier Inc. All rights reserved.
Use of a wireless, inertial sensor-based system to objectively evaluate flexion tests in the horse.
Marshall, J F; Lund, D G; Voute, L C
2012-12-01
A wireless, inertial sensor-based system has previously been validated for evaluation of equine lameness. However, threshold values have not been determined for the assessment of responses to flexion tests. The aim of this investigation was to evaluate a sensor-based system for objective assessment of the response to flexion. Healthy adult horses (n = 17) in work were recruited prospectively. Horses were instrumented with sensors on the head (accelerometer), pelvis (accelerometer) and right forelimb (gyroscope), before trotting in a straight line (minimum 25 strides) for 2 consecutive trials. Sensors measured 1) vertical pelvic movement asymmetry (PMA) for both right and left hindlimb strides and 2) average difference in maximum and minimum pelvic height (PDMax and PDMin) between right and left hindlimb strides in millimetres. A hindlimb was randomly selected for proximal flexion (60 s), after which the horse trotted a minimum of 10 strides. Response to flexion was blindly assessed as negative or positive by an experienced observer. Changes in PMA, PDMax and PDMin between baseline and flexion examinations were calculated for each test. Statistical analysis consisted of a Pearson's product moment test and linear regression on baseline trials, Mann-Whitney rank sum test for effect of flexion and receiver operator curve (ROC) analysis of test parameters. There was a strong correlation between trials for PMA, PDMin and PDMax measurements (P < 0.001). A positive flexion test resulted in a significant increase in PMA (P = 0.021) and PDMax (P = 0.05) only. Receiver-operator curve analysis established cut-off values for change in PMA and PDMax of 0.068 and 4.47 mm, respectively (sensitivity = 0.71, specificity = 0.65) to indicate a positive response to flexion. A positive response to flexion resulted in significant changes to objective measurements of pelvic symmetry. Findings support the use of inertial sensor systems to objectively assess response to flexion tests. Further investigation is warranted to establish cut-off values for objective assessment of other diagnostic procedures.
Multiple layer optical memory system using second-harmonic-generation readout
Boyd, Gary T.; Shen, Yuen-Ron
1989-01-01
A novel optical read and write information storage system is described which comprises a radiation source such as a laser for writing and illumination, the radiation source being capable of radiating a preselected first frequency; a storage medium including at least one layer of material for receiving radiation from the radiation source and capable of being surface modified in response to said radiation source when operated in a writing mode and capable of generating a pattern of radiation of the second harmonic of the preselected frequency when illuminated by the radiation source at the preselected frequency corresponding to the surface modifications on the storage medium; and a detector to receive the pattern of second harmonic frequency generated.
Charging up the public for automated external defibrillators
Willoughby DeJesus, Paula
2005-01-01
Public training in the use of automated external defibrillators to treat out-of-hospital cardiac arrests has been receiving increased attention. The implementation of public access defibrillation programs has been the most significant intervention to improve survival in decades. Dramatic success came when we placed automated external defibrillators in the hands of the public to be utilized without an Emergency Medical Services response having to occur. The device is simple to operate – sixth-grade children have demonstrated safe and effective operation. Training should be taken to its elemental level. Cardiopulmonary resuscitation training should not be forgotten; it too should be taken to its simplest form. PMID:15774067
Rectennas at optical frequencies: How to analyze the response
NASA Astrophysics Data System (ADS)
Joshi, Saumil; Moddel, Garret
2015-08-01
Optical rectennas, antenna-coupled diode rectifiers that receive optical-frequency electromagnetic radiation and convert it to DC output, have been proposed for use in harvesting electromagnetic radiation from a blackbody source. The operation of these devices is qualitatively different from that of lower-frequency rectennas, and their design requires a new approach. To that end, we present a method to determine the rectenna response to high frequency illumination. It combines classical circuit analysis with classical and quantum-based photon-assisted tunneling response of a high-speed diode. We demonstrate the method by calculating the rectenna response for low and high frequency monochromatic illumination, and for radiation from a blackbody source. Such a blackbody source can be a hot body generating waste heat, or radiation from the sun.
Multiple-degree-of-freedom vehicle
Borenstein, Johann
1995-01-01
A multi-degree-of-freedom vehicle employs a compliant linkage to accommodate the need for a variation in the distance between drive wheels or drive systems which are independently steerable and drivable. The subject vehicle is provided with rotary encodes to provide signals representative of the orientation of the steering pivot associated with each such drive wheel or system, and a linear encoder which issues a signal representative of the fluctuations in the distance between the drive elements. The wheels of the vehicle are steered and driven in response to the linear encoder signal, there being provided a controller system for minimizing the fluctuations in the distance. The controller system is a software implementation of a plurality of controllers, operating at the chassis level and at the vehicle level. A trajectory interpolator receives x-displacement, y-displacement, and .theta.-displacement signals and produces to the vehicle level controller trajectory signals corresponding to interpolated control signals. The x-displacement, y-displacement, and .theta.-displacement signals are received from a human operator, via a manipulable joy stick.
NASA Astrophysics Data System (ADS)
Terada, Takahide; Yamanaka, Kazuhiro; Suzuki, Atsuro; Tsubota, Yushi; Wu, Wenjing; Kawabata, Ken-ichi
2017-07-01
Ultrasound computed tomography (USCT) is promising for a non-invasive, painless, operator-independent and quantitative system for breast-cancer screening. Assembly error, production tolerance, and aging-degradation variations of the hardwire components, particularly of plane-wave-based USCT systems, may hamper cost effectiveness, precise imaging, and robust operation. The plane wave is transmitted from a ring-shaped transducer array for receiving the signal at a high signal-to-noise-ratio and fast aperture synthesis. There are four signal-delay components: response delays in the transmitters and receivers and propagation delays depending on the positions of the transducer elements and their directivity. We developed a highly precise calibration method for calibrating these delay components and evaluated it with our prototype plane-wave-based USCT system. Our calibration method was found to be effective in reducing delay errors. Gaps and curves were eliminated from the plane wave, and echo images of wires were sharpened in the entire imaging area.
Range-gated field disturbance sensor with range-sensitivity compensation
McEwan, T.E.
1996-05-28
A field disturbance sensor operates with relatively low power, provides an adjustable operating range, is not hypersensitive at close range, allows co-location of multiple sensors, and is inexpensive to manufacture. The sensor includes a transmitter that transmits a sequence of transmitted bursts of electromagnetic energy. The transmitter frequency is modulated at an intermediate frequency. The sequence of bursts has a burst repetition rate, and each burst has a burst width and comprises a number of cycles at a transmitter frequency. The sensor includes a receiver which receives electromagnetic energy at the transmitter frequency, and includes a mixer which mixes a transmitted burst with reflections of the same transmitted burst to produce an intermediate frequency signal. Circuitry, responsive to the intermediate frequency signal indicates disturbances in the sensor field. Because the mixer mixes the transmitted burst with reflections of the transmitted burst, the burst width defines the sensor range. The burst repetition rate is randomly or pseudorandomly modulated so that bursts in the sequence of bursts have a phase which varies. 8 figs.
Range-gated field disturbance sensor with range-sensitivity compensation
McEwan, Thomas E.
1996-01-01
A field disturbance sensor operates with relatively low power, provides an adjustable operating range, is not hypersensitive at close range, allows co-location of multiple sensors, and is inexpensive to manufacture. The sensor includes a transmitter that transmits a sequence of transmitted bursts of electromagnetic energy. The transmitter frequency is modulated at an intermediate frequency. The sequence of bursts has a burst repetition rate, and each burst has a burst width and comprises a number of cycles at a transmitter frequency. The sensor includes a receiver which receives electromagnetic energy at the transmitter frequency, and includes a mixer which mixes a transmitted burst with reflections of the same transmitted burst to produce an intermediate frequency signal. Circuitry, responsive to the intermediate frequency signal indicates disturbances in the sensor field. Because the mixer mixes the transmitted burst with reflections of the transmitted burst, the burst width defines the sensor range. The burst repetition rate is randomly or pseudorandomly modulated so that bursts in the sequence of bursts have a phase which varies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richardson, W.J.; Greene, C.R.; Koski, W.R.
1991-10-01
The report concerns the effects of underwater noise from simulated oil production operations on the movements and behavior of bowhead and white whales migrating around northern Alaska in spring. An underwater sound projector suspended from pack ice was used to introduce recorded drilling noise and other test sounds into leads through the pack ice. These sounds were received and measured at various distances to determine the rate of sound attenuation with distance and frequency. The movements and behavior of bowhead and white whales approaching the operating projector were studied by aircraft- and ice-based observers. Some individuals of both species weremore » observed to approach well within the ensonified area. However, behavioral changes and avoidance reactions were evident when the received sound level became sufficiently high. Reactions to aircraft are also discussed.« less
Implementation of critical care response team.
Al Shimemeri, Abdullah
2014-04-01
Analyses of hospital deaths have indicated that a significant proportion of the reported deaths might have been prevented had the patients received intensive level care early enough. Over the past few decades the critical care response team has become an important means of preventing these deaths. As the proactive arm of intensive care delivery, the critical care response team places emphasis on early identification of signs of clinical deterioration, which then prompts the mobilization of intensive care brought right to the patient's bedside. However, the setting up of a critical care response team is a difficult undertaking involving different levels of cooperation between all service stakeholders, and a bringing together of professional expertise and experience in its operations. The implementation of a critical care response team often involves a high-level restructuring of a hospital's service orientation. In the present work, the various factors and different models to be considered in implementing a critical care response team are addressed.
Félix, Nuno M; Leal, Rodolfo O; Goy-Thollot, I; Walton, Ronald S; Gil, Solange A; Mateus, Luísa M; Matos, Ana S; Niza, Maria M R E
2017-01-01
Objective(s): Buprenorphine is a common analgesic in experimental research, due to effectiveness and having few side-effects, including a limited influence in the immune and endocrine systems. However, how buprenorphine affects cytokine levels and the adrenal and thyroid response during general anesthesia and surgery is incompletely understood. This study aimed to assess whether buprenorphine modulated significantly those responses in rats submitted to general anesthesia, mechanical ventilation, and surgical insertion of intravascular catheters. Materials and Methods: Animals were anesthetized with isoflurane, mechanically ventilated, and surgically instrumented for carotid artery and the femoral vein catheter placement. The test group (n=16), received buprenorphine subcutaneously before surgery, whereas the control group (n=16) received normal saline. Blood sampling to determine plasma levels of adrenocorticotropic hormone (ACTH), corticosterone (CS), total thyroxine (TT4), total triiodothyronine (TT3), thyroid-stimulating hormone (TSH), TNF-α, IL6, IL10, TNF-α, IL6, and IL10 mRNA was performed at 10 min after completion of all surgical procedures and at 90, 150, 240, and 300 min thereafter, with the animals still anesthetized and with mechanical ventilation. Results: Buprenorphine-treated animals had higher levels of ACTH, CS, and TT4 at several time points (P<0.05) and TSH and TT3 at all-time points (P<0.05). They also had increased IL10, TNF-α, and IL10 mRNA levels. Conclusion: In this model, buprenorphine significantly modulated the intra-operative cytokine and endocrine response to anesthesia, mechanical ventilation, and surgical placement of intravascular catheters. The mechanism and significance of these findings remain undetermined. Researchers should be aware of these effects when considering the use of buprenorphine for analgesic purposes. PMID:28804607
Centralization vs. decentralization in medical school libraries.
Crawford, H
1966-07-01
Does the medical school library in the United States operate more commonly under the university library or the medical school administration? University-connected medical school libraries were asked to indicate (a) the source of their budgets, whether from the central library or the medical school, and (b) the responsibility for their acquisitions and cataloging. Returns received from sixtyeight of the seventy eligible institutions showed decentralization to be much the most common: 71 percent of the libraries are funded by their medical schools; 79 percent are responsible for their own acquisitions and processing. The factor most often associated with centralization of both budget and operation is public ownership. Decentralization is associated with service to one or two rather than three or more professional schools. Location of the medical school in a different city from the university is highly favorable to autonomy. Other factors associated with these trends are discussed.
Centralization vs. Decentralization in Medical School Libraries
Crawford, Helen
1966-01-01
Does the medical school library in the United States operate more commonly under the university library or the medical school administration? University-connected medical school libraries were asked to indicate (a) the source of their budgets, whether from the central library or the medical school, and (b) the responsibility for their acquisitions and cataloging. Returns received from sixtyeight of the seventy eligible institutions showed decentralization to be much the most common: 71 percent of the libraries are funded by their medical schools; 79 percent are responsible for their own acquisitions and processing. The factor most often associated with centralization of both budget and operation is public ownership. Decentralization is associated with service to one or two rather than three or more professional schools. Location of the medical school in a different city from the university is highly favorable to autonomy. Other factors associated with these trends are discussed. PMID:5945568
Evaluation of an audience response system in a preclinical operative dentistry course.
Elashvili, Ana; Denehy, Gerald E; Dawson, Deborah V; Cunningham, Marsha A
2008-11-01
Student performance was compared on written and psychomotor skill tests of freshman dental students receiving conventional lectures versus the same lectures containing interactive components using TurningPoint, a wireless audience response system (ARS). The research design was a controlled crossover study with seventy-seven freshman dental students conducted in a preclinical operative dentistry course. Two randomized groups alternated the two study lectures, one with ARS and the other without ARS. Student knowledge retention was measured through written examination using immediate posttest, as well as questions on the unit and final examinations. Psychomotor skill tests were given on both lecture topics. Statistically significant differences indicating superiority of ARS were identified for performance on the immediate posttest and psychomotor skill test only for the lecture "Principles of Dental Bonding." The other examinations/skill testing showed no significant difference. These results indicate that ARS is a promising teaching tool for dental education.
A mixed Rasch model of dual-process conditional reasoning.
Bonnefon, Jean-François; Eid, Michael; Vautier, Stéphane; Jmel, Saïd
2008-05-01
A fine-grained dual-process approach to conditional reasoning is advocated: Responses to conditional syllogisms are reached through the operation of either one of two systems, each of which can rely on two different mechanisms. System1 relies either on pragmatic implicatures or on the retrieval of information from semantic memory; System2 operates first through inhibition of System1, then (but not always) through activation of analytical processes. It follows that reasoners will fall into one of four groups of increasing reasoning ability, each group being uniquely characterized by (a) the modal pattern of individual answers to blocks of affirming the consequent (AC), denying the antecedent (DA), and modus tollens (MT) syllogisms featuring the same conditional; and (b) the average rate of determinate answers to AC, DA, and MT. This account receives indirect support from the extant literature and direct support from a mixed Rasch model of responses given to 18 syllogisms by 486 adult reasoners.
Operative team communication during simulated emergencies: Too busy to respond?
Davis, W Austin; Jones, Seth; Crowell-Kuhnberg, Adrianna M; O'Keeffe, Dara; Boyle, Kelly M; Klainer, Suzanne B; Smink, Douglas S; Yule, Steven
2017-05-01
Ineffective communication among members of a multidisciplinary team is associated with operative error and failure to rescue. We sought to measure operative team communication in a simulated emergency using an established communication framework called "closed loop communication." We hypothesized that communication directed at a specific recipient would be more likely to elicit a check back or closed loop response and that this relationship would vary with changes in patients' clinical status. We used the closed loop communication framework to code retrospectively the communication behavior of 7 operative teams (each comprising 2 surgeons, anesthesiologists, and nurses) during response to a simulated, postanesthesia care unit "code blue." We identified call outs, check backs, and closed loop episodes and applied descriptive statistics and a mixed-effects negative binomial regression to describe characteristics of communication in individuals and in different specialties. We coded a total of 662 call outs. The frequency and type of initiation and receipt of communication events varied between clinical specialties (P < .001). Surgeons and nurses initiated fewer and received more communication events than anesthesiologists. For the average participant, directed communication increased the likelihood of check back by at least 50% (P = .021) in periods preceding acute changes in the clinical setting, and exerted no significant effect in periods after acute changes in the clinical situation. Communication patterns vary by specialty during a simulated operative emergency, and the effect of directed communication in eliciting a response depends on the clinical status of the patient. Operative training programs should emphasize the importance of quality communication in the period immediately after an acute change in the clinical setting of a patient and recognize that communication patterns and needs vary between members of multidisciplinary operative teams. Copyright © 2016 Elsevier Inc. All rights reserved.
Fry, Jillian P; Laestadius, Linnea I; Grechis, Clare; Nachman, Keeve E; Neff, Roni A
2014-01-01
Industrial food animal production (IFAP) operations adversely impact environmental public health through air, water, and soil contamination. We sought to determine how state permitting and agriculture agencies respond to these public health concerns. We conducted semi-structured qualitative interviews with staff at 12 state agencies in seven states, which were chosen based on high numbers or rapid increase of IFAP operations. The interviews served to gather information regarding agency involvement in regulating IFAP operations, the frequency and type of contacts received about public health concerns, how the agency responds to such contacts, and barriers to additional involvement. Permitting and agriculture agencies' responses to health-based IFAP concerns are constrained by significant barriers including narrow regulations, a lack of public health expertise within the agencies, and limited resources. State agencies with jurisdiction over IFAP operations are unable to adequately address relevant public health concerns due to multiple factors. Combining these results with previously published findings on barriers facing local and state health departments in the same states reveals significant gaps between these agencies regarding public health and IFAP. There is a clear need for regulations to protect public health and for public health professionals to provide complementary expertise to agencies responsible for regulating IFAP operations.
29 CFR 1917.155 - Air receivers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 29 Labor 7 2012-07-01 2012-07-01 false Air receivers. 1917.155 Section 1917.155 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.155 Air receivers. (a) Application. This section applies to compressed air receivers and equipment used for operations such as cleaning...
29 CFR 1917.155 - Air receivers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 29 Labor 7 2014-07-01 2014-07-01 false Air receivers. 1917.155 Section 1917.155 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.155 Air receivers. (a) Application. This section applies to compressed air receivers and equipment used for operations such as cleaning...
29 CFR 1917.155 - Air receivers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 29 Labor 7 2013-07-01 2013-07-01 false Air receivers. 1917.155 Section 1917.155 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.155 Air receivers. (a) Application. This section applies to compressed air receivers and equipment used for operations such as cleaning...
29 CFR 1917.155 - Air receivers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 29 Labor 7 2011-07-01 2011-07-01 false Air receivers. 1917.155 Section 1917.155 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.155 Air receivers. (a) Application. This section applies to compressed air receivers and equipment used for operations such as cleaning...
29 CFR 1917.155 - Air receivers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 29 Labor 7 2010-07-01 2010-07-01 false Air receivers. 1917.155 Section 1917.155 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.155 Air receivers. (a) Application. This section applies to compressed air receivers and equipment used for operations such as cleaning...
Afghanistan: Post-Taliban Governance, Security, and U.S. Policy
2014-12-02
collection of information is estimated to average 1 hour per response, including the time for reviewing instructions , searching existing data sources...notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a ...to operate informally .9 In March 2001, Administration officials received a Taliban envoy to discuss bilateral issues. In one significant departure
Early Change in Stroke Size Performs Best in Predicting Response to Therapy.
Simpkins, Alexis Nétis; Dias, Christian; Norato, Gina; Kim, Eunhee; Leigh, Richard
2017-01-01
Reliable imaging biomarkers of response to therapy in acute stroke are needed. The final infarct volume and percent of early reperfusion have been used for this purpose. Early fluctuation in stroke size is a recognized phenomenon, but its utility as a biomarker for response to therapy has not been established. This study examined the clinical relevance of early change in stroke volume and compared it with the final infarct volume and percent of early reperfusion in identifying early neurologic improvement (ENI). Acute stroke patients, enrolled between 2013 and 2014 with serial magnetic resonance imaging (MRI) scans (pretreatment baseline, 2 h post, and 24 h post), who received thrombolysis were included in the analysis. Early change in stroke volume, infarct volume at 24 h on diffusion, and percent of early reperfusion were calculated from the baseline and 2 h MRI scans were compared. ENI was defined as ≥4 point decrease in National Institutes of Health Stroke Scales within 24 h. Logistic regression models and receiver operator characteristics analysis were used to compare the efficacy of 3 imaging biomarkers. Serial MRIs of 58 acute stroke patients were analyzed. Early change in stroke volume was significantly associated with ENI by logistic regression analysis (OR 0.93, p = 0.048) and remained significant after controlling for stroke size and severity (OR 0.90, p = 0.032). Thus, for every 1 mL increase in stroke volume, there was a 10% decrease in the odds of ENI, while for every 1 mL decrease in stroke volume, there was a 10% increase in the odds of ENI. Neither infarct volume at 24 h nor percent of early reperfusion were significantly associated with ENI by logistic regression. Receiver-operator characteristic analysis identified early change in stroke volume as the only biomarker of the 3 that performed significantly different than chance (p = 0.03). Early fluctuations in stroke size may represent a more reliable biomarker for response to therapy than the more traditional measures of final infarct volume and percent of early reperfusion. © 2017 S. Karger AG, Basel.
Predictions of GPS X-Set Performance during the Places Experiment
1979-07-01
previously existing GPS X-set receiver simulation was modified to include the received signal spectrum and the receiver code correlation operation... CORRELATION OPERATION The X-set receiver simulation documented in Reference 3-1 is a direct sampled -data digital implementation of the GPS X-set...ul(t) -sin w2t From Carrier and Code Loops (wit +0 1 (t)) Figure 3-6. Simplified block diagram of code correlator operation and I-Q sampling . 6 I
Mitigating Photon Jitter in Optical PPM Communication
NASA Technical Reports Server (NTRS)
Moision, Bruce
2008-01-01
A theoretical analysis of photon-arrival jitter in an optical pulse-position-modulation (PPM) communication channel has been performed, and now constitutes the basis of a methodology for designing receivers to compensate so that errors attributable to photon-arrival jitter would be minimized or nearly minimized. Photon-arrival jitter is an uncertainty in the estimated time of arrival of a photon relative to the boundaries of a PPM time slot. Photon-arrival jitter is attributable to two main causes: (1) receiver synchronization error [error in the receiver operation of partitioning time into PPM slots] and (2) random delay between the time of arrival of a photon at a detector and the generation, by the detector circuitry, of a pulse in response to the photon. For channels with sufficiently long time slots, photon-arrival jitter is negligible. However, as durations of PPM time slots are reduced in efforts to increase throughputs of optical PPM communication channels, photon-arrival jitter becomes a significant source of error, leading to significant degradation of performance if not taken into account in design. For the purpose of the analysis, a receiver was assumed to operate in a photon- starved regime, in which photon counts follow a Poisson distribution. The analysis included derivation of exact equations for symbol likelihoods in the presence of photon-arrival jitter. These equations describe what is well known in the art as a matched filter for a channel containing Gaussian noise. These equations would yield an optimum receiver if they could be implemented in practice. Because the exact equations may be too complex to implement in practice, approximations that would yield suboptimal receivers were also derived.
Impact of signal scattering and parametric uncertainties on receiver operating characteristics
NASA Astrophysics Data System (ADS)
Wilson, D. Keith; Breton, Daniel J.; Hart, Carl R.; Pettit, Chris L.
2017-05-01
The receiver operating characteristic (ROC curve), which is a plot of the probability of detection as a function of the probability of false alarm, plays a key role in the classical analysis of detector performance. However, meaningful characterization of the ROC curve is challenging when practically important complications such as variations in source emissions, environmental impacts on the signal propagation, uncertainties in the sensor response, and multiple sources of interference are considered. In this paper, a relatively simple but realistic model for scattered signals is employed to explore how parametric uncertainties impact the ROC curve. In particular, we show that parametric uncertainties in the mean signal and noise power substantially raise the tails of the distributions; since receiver operation with a very low probability of false alarm and a high probability of detection is normally desired, these tails lead to severely degraded performance. Because full a priori knowledge of such parametric uncertainties is rarely available in practice, analyses must typically be based on a finite sample of environmental states, which only partially characterize the range of parameter variations. We show how this effect can lead to misleading assessments of system performance. For the cases considered, approximately 64 or more statistically independent samples of the uncertain parameters are needed to accurately predict the probabilities of detection and false alarm. A connection is also described between selection of suitable distributions for the uncertain parameters, and Bayesian adaptive methods for inferring the parameters.
Design and performance of the collective Thomson scattering receiver at ASDEX Upgrade.
Furtula, V; Salewski, M; Leipold, F; Michelsen, P K; Korsholm, S B; Meo, F; Moseev, D; Nielsen, S K; Stejner, M; Johansen, T
2012-01-01
Here we present the design of the fast-ion collective Thomson scattering receiver for millimeter wave radiation installed at ASDEX Upgrade, a tokamak for fusion plasma experiments. The receiver can detect spectral power densities of a few eV against the electron cyclotron emission background on the order of 100 eV under presence of gyrotron stray radiation that is several orders of magnitude stronger than the signal to be detected. The receiver down converts the frequencies of scattered radiation (100-110 GHz) to intermediate frequencies (IF) (4.5-14.5 GHz) by heterodyning. The IF signal is divided into 50 IF channels tightly spaced in frequency space. The channels are terminated by square-law detector diodes that convert the signal power into DC voltages. We present measurements of the transmission characteristics and performance of the main receiver components operating at mm-wave frequencies (notch, bandpass, and lowpass filters, a voltage-controlled variable attenuator, and an isolator), the down-converter unit, and the IF components (amplifiers, bandpass filters, and detector diodes). Furthermore, we determine the performance of the receiver as a unit through spectral response measurements and find reasonable agreement with the expectation based on the individual component measurements.
Performance prediction evaluation of ceramic materials in point-focusing solar receivers
NASA Technical Reports Server (NTRS)
Ewing, J.; Zwissler, J.
1979-01-01
A performance prediction was adapted to evaluate the use of ceramic materials in solar receivers for point focusing distributed applications. System requirements were determined including the receiver operating environment and system operating parameters for various engine types. Preliminary receiver designs were evolved from these system requirements. Specific receiver designs were then evaluated to determine material functional requirements.
Convexity of Energy-Like Functions: Theoretical Results and Applications to Power System Operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dvijotham, Krishnamurthy; Low, Steven; Chertkov, Michael
2015-01-12
Power systems are undergoing unprecedented transformations with increased adoption of renewables and distributed generation, as well as the adoption of demand response programs. All of these changes, while making the grid more responsive and potentially more efficient, pose significant challenges for power systems operators. Conventional operational paradigms are no longer sufficient as the power system may no longer have big dispatchable generators with sufficient positive and negative reserves. This increases the need for tools and algorithms that can efficiently predict safe regions of operation of the power system. In this paper, we study energy functions as a tool to designmore » algorithms for various operational problems in power systems. These have a long history in power systems and have been primarily applied to transient stability problems. In this paper, we take a new look at power systems, focusing on an aspect that has previously received little attention: Convexity. We characterize the domain of voltage magnitudes and phases within which the energy function is convex in these variables. We show that this corresponds naturally with standard operational constraints imposed in power systems. We show that power of equations can be solved using this approach, as long as the solution lies within the convexity domain. We outline various desirable properties of solutions in the convexity domain and present simple numerical illustrations supporting our results.« less
The use of UAS in disaster response operations
NASA Astrophysics Data System (ADS)
Gkotsis, I.; Eftychidis, G.; Kolios, P.
2017-09-01
The use of UAS by the emergency services has been received with great interest since UAS provide both informant and helper support in a flexible, effective and efficient manner. This is due to the fact that, UAS can strengthen the operational capabilities related to: prevention (e.g., patrolling of large and hard to reach areas), early detection (e.g., mapping of vulnerable elements), disaster preparedness (e.g., incident inspection), response (mapping damages, search and rescue, provide an ad hoc communication network, monitor evacuation, etc). Through PREDICATE, a project concerning civilian use of drones, the necessary methodologies to guide the selection and operational use of UAS in emergencies, are developed. To guide UAS selection, the project performed a detailed needs assessment in cooperation with civil protection and law enforcement agencies. As a result of this assessment, currently available technologies and market solutions were reviewed leading to the development of an online user-friendly tool to support selection of UAS based on operational requirements. To guide the use of UAS, PREDICATE developed an intelligent path planning toolkit to automate the operation of UAS and ease their use for the various civil protection operations. By employing the aforementioned tools, emergency services will be able to better understand how to select and make use of UAS for watch-keeping and patrolling of their own disaster-prone Regions of Interest. The research, innovation and applicability behind both these tools is detailed in this work.
van Helvoirt, Hans; Apeldoorn, Adri T; Knol, Dirk L; Arts, Mark P; Kamper, Steven J; van Tulder, Maurits W; Ostelo, Raymond W
2016-04-27
Prospective cohort study. Although lumbar radiculopathy is regarded as a specific diagnosis, the most effective treatment strategy is unclear. Commonly used treatments include transforaminal epidural steroid injections (TESIs) and Mechanical Diagnosis & Therapy (MDT), but no studies have investigated the effectiveness of this combination. MDT differentiates pain centralization (C) from non-centralization (NC), which indicates good vs. poor prognostic validity respectively. The main aims were 1) to determine changes in Mechanical Diagnosis and Therapy (MDT) pain response classifications after transforaminal epidural steroid injections (TESIs) in candidates for lumbar herniated disc surgery and 2) to evaluate differences in short and long term outcomes for patients with different pain response classifications. Candidates for lumbar herniated disc surgery were assessed with a MDT protocol and their pain response classified as centralizing or peripheralizing. For this study,only patients were eligible who showed a peripheralizing pain response at intake. All patients then received TESIs and were reassessed and classified using the MDT protocol, into groups according to pain response (resolved, centralizing, peripheralizing with less pain and peripheralising with severe pain). After receiving targeted treatment based on pain response after TESIs, ranging from advice, MDT or surgery, follow-up assessments were completed at discharge and at 12 months. The primary outcomes were disability (Roland-Morris Disability Questionnaire [RMDQ] for Sciatica), pain severity in leg (visual analogue scale [VAS], 0-100) and global perceived effect (GPE). Linear mixed-models were used to determine between-groups differences in outcome. A total of 77 patients with lumbar disc herniation and peripheralizing symptoms were included. Patients received an average of 2 (SD 0.7) TESIs. After TESIs, 17 patients (22%) were classified as peripheralizing with continuing severe pain.These patients underwent surgery and were not further evaluated. Eleven (14%) patients were classified as resolved, 37 (48%) as centralizing with significant less pain, and 12 (16%) as peripheralizing with significant less pain. None of these patients underwent surgery. Resolved and centralizer subgroups had better outcomes in terms of VAS and RMDQ than the non-operated peripheralizers at discharge and at 12 months. The succes rates (GPE) for the resolved, centralizing, and peripheralizing with less pain patients were 100%, 100% and 33% respectively at short term, and 100%, 92% and 50% respectively at long term. After TESIs, a peripheralizing pain pattern changed to resolved or centralizing in 62% of the patients. For the non-operated patients, those with a centralising pattern after TESIs reported better pain and disability outcomes than those with peripheralizing pattern at short and long term.
Self-pacing direct memory access data transfer operations for compute nodes in a parallel computer
Blocksome, Michael A
2015-02-17
Methods, apparatus, and products are disclosed for self-pacing DMA data transfer operations for nodes in a parallel computer that include: transferring, by an origin DMA on an origin node, a RTS message to a target node, the RTS message specifying an message on the origin node for transfer to the target node; receiving, in an origin injection FIFO for the origin DMA from a target DMA on the target node in response to transferring the RTS message, a target RGET descriptor followed by a DMA transfer operation descriptor, the DMA descriptor for transmitting a message portion to the target node, the target RGET descriptor specifying an origin RGET descriptor on the origin node that specifies an additional DMA descriptor for transmitting an additional message portion to the target node; processing, by the origin DMA, the target RGET descriptor; and processing, by the origin DMA, the DMA transfer operation descriptor.
NASA Astrophysics Data System (ADS)
Nordin, Noraimi Azlin Mohd; Omar, Mohd; Sharif, S. Sarifah Radiah
2017-04-01
Companies are looking forward to improve their productivity within their warehouse operations and distribution centres. In a typical warehouse operation, order picking contributes more than half percentage of the operating costs. Order picking is a benchmark in measuring the performance and productivity improvement of any warehouse management. Solving order picking problem is crucial in reducing response time and waiting time of a customer in receiving his demands. To reduce the response time, proper routing for picking orders is vital. Moreover, in production line, it is vital to always make sure the supplies arrive on time. Hence, a sample routing network will be applied on EP Manufacturing Berhad (EPMB) as a case study. The Dijkstra's algorithm and Dynamic Programming method are applied to find the shortest distance for an order picker in order picking. The results show that the Dynamic programming method is a simple yet competent approach in finding the shortest distance to pick an order that is applicable in a warehouse within a short time period.
Toyoda, Hidenori; Kumada, Takashi; Tada, Toshifumi; Yama, Tsuyoki; Mizuno, Kazuyuki
2018-06-01
On-treatment response of serum hepatitis C virus (HCV) is reportedly less useful to predict the outcome of anti-HCV therapy with interferon (IFN)-free regimen with direct-acting antivirals than with IFN-based regimens in clinical trials. We evaluated the significance of very early viral response after the start of therapy, which indicates direct HCV response to the drugs, on therapeutic outcome. Reductions in serum HCV-RNA levels were measured at 1 day after the start of therapy in 544 patients who underwent IFN-free direct-acting antiviral regimens. The association between these reductions and the achievement or failure of sustained virologic response (SVR) was evaluated. Patient characteristics did not influence 1-day reduction in serum HCV-RNA except for liver fibrosis. There was no difference in 1-day HCV reduction between SVR and non-SVR patients treated with a 24-week regimen. In contrast, in patients treated with a 12-week regimen, 1-day reduction was significantly greater in SVR than in non-SVR patients (P = 0.0013) and was predictive of SVR versus non-SVR (area under the receiver-operating characteristics curve: 0.80). Whereas the reduction in serum HCV-RNA levels at 1 day after the start of therapy was not associated with treatment outcomes in patients who underwent a 24-week regimen of IFN-free therapy, there was an association in patients receiving a 12-week regimen, and this reduction was predictive of SVR, thus potentially serving as a factor to identify patients at risk of treatment failure. © 2017 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.
PUNISHING AND CARDIOVASCULAR EFFECTS OF INTRAVENOUS HISTAMINE IN RATS: PHARMACOLOGICAL SELECTIVITY
Podlesnik, Christopher A.; Jimenez-Gomez, Corina
2014-01-01
Although drugs may serve as reinforcers or punishers of operant behavior, the punishing function has received much less experimental attention than the reinforcing function. A sensitive method for studying drug-induced punishment is to assess choice for a punished response over an unpunished response. In these experiments, rats chose between pressing one lever and receiving a sucrose pellet or pressing another lever and receiving a sucrose pellet plus an intravenous injection of histamine. When sucrose was delivered equally frequently for either the punished or the unpunished response, rats selected the unpunished lever consistently, but decreases in the punished response did not differ as a function of intravenous histamine dose (0.1–1 mg/kg/inj). Changing the procedure so that sucrose was delivered on the unpunished lever with p = .5 increased the rats’ responding on the punished lever with saline injections. In addition, the same range of histamine doses produced a much larger range of responses on the punished lever that was dose dependent. Using these procedures to assess the receptors mediating histamine’s effects, the histamine H1-receptor antagonists, pyrilamine and ketotifen, antagonized the punishing effect of histamine, but the histamine H2-receptor antagonist ranitidine did not. However, ranitidine pretreatments reduced histamine-induced heart-rate increases to a greater extent than did the histamine H1-receptor antagonists when administered at the same doses examined under conditions of histamine punishment. Overall, the present findings extend the general hypothesis that activation of histamine H1-receptors mediates the punishing effects of histamine. They also introduce methods for rapidly assessing pharmacological mechanisms underlying drug-induced punishment. PMID:23982898
Science operations planning and implementation for Rosetta
NASA Astrophysics Data System (ADS)
Koschny, Detlef; Sweeney, Mark; Montagon, Elsa; Hoofs, Raymond; van der Plas, Peter
2002-07-01
The Rosetta mission is a cornerstone mission of the Horizon 2000 programme of the European Space Agency. It will be launched to comet 46P/Wirtanen in January 2003. This mission is the first of a series of planetary missions, including Mars Express, Smart-I (to the Moon), and BepiColombo (to Mercury). All these missions have similar requirements for their scientific operations. The Experiments H/W and S/W are developed by Principal Investigators, working at scientific institutes. They are also responsible for the operation of their experiments and for the generation of related operational documentation. The Science Operations Centre (SOC) has the task to consolidate the inputs of the different experimenters and the Lander and ensure that the resulting science operations timeline is free of conflicts. It forwards this timeline to the Mission Operations Centre (MOC) which combines the science operations with the operations of the other spacecraft subsystems and the orbit and attitude of the spacecraft. The MOC is also responsible for uplinking the operational command sequences to the spacecraft and for returning the received telemetry to the user. In a collaboration between the team of the Rosetta Project Scientist at the Research and Science Support Department of ESA/ESTEC and the European Space Operations Centre (ESA/ESOC), a concept for the SOC/MOC and their interfaces was developed for the Rosetta mission. This concept is generic enough to allow its implementation also for the other planetary missions. The design phase is now complete, and implementation is on-going. This paper briefly presents the architecture of the complex ground segment, concentrating on the elements required for planning of scientific operations, and then details the software tools EPS (Experiment Planning System) and PTB (Project Test Bed) which are used in the planning process.
NASA Astrophysics Data System (ADS)
Wells, G. L.; Tapley, B. D.; Bettadpur, S. V.; Howard, T.; Porter, B.; Smith, S.; Teng, L.; Tapley, C.
2014-12-01
The effective use of remote sensing products as guidance to emergency managers and first responders during field operations requires close coordination and communication with state-level decision makers, incident commanders and the leaders of individual strike teams. Information must be tailored to meet the needs of different emergency support functions and must contain current (ideally near real-time) data delivered in standard formats in time to influence decisions made under rapidly changing conditions. Since 2003, a representative of the University of Texas Center for Space Research (CSR) has served as a member of the Governor's Emergency Management Council and has directed the flow of information from remote sensing observations and high performance computing modeling and simulations to the Texas Division of Emergency Management in the State Operations Center. The CSR team has supported response and recovery missions resulting from hurricanes, tornadoes, flash floods, wildfires, oil spills and other natural and man-made disasters in Texas and surrounding states. Through web mapping services, state emergency managers and field teams have received threat model forecasts, real-time vehicle tracking displays and imagery to support search-and-clear operations before hurricane landfall, search-and-rescue missions following floods, tactical wildfire suppression, pollution monitoring and hazardous materials detection. Data servers provide near real-time satellite imagery collected by CSR's direct broadcast receiving system and post data products delivered during activations of the United Nations International Charter on Space and Major Disasters. In the aftermath of large-scale events, CSR is charged with tasking state aviation resources, including the Air National Guard and Texas Civil Air Patrol, to acquire geolocated aerial photography of the affected region for wide area damage assessment. A data archive for each disaster is available online for years following the event to assist forensic studies and local plans for recovery. The use of portable devices, including commodity smartphones and tablets, will soon permit even more responsive data delivery during future disasters through the expansion of wireless Public Safety Broadband (FirstNet) targeted to serve first responders.
Bajpai, Jyoti; Gamnagatti, Shivanand; Kumar, Rakesh; Sreenivas, Vishnubhatla; Sharma, Mehar Chand; Khan, Shah Alam; Rastogi, Shishir; Malhotra, Arun; Safaya, Rajni; Bakhshi, Sameer
2011-04-01
Histological necrosis, the current standard for response evaluation in osteosarcoma, is attainable after neoadjuvant chemotherapy. To establish the role of surrogate markers of response prediction and evaluation using MRI in the early phases of the disease. Thirty-one treatment-naïve osteosarcoma patients received three cycles of neoadjuvant chemotherapy followed by surgery during 2006-2008. All patients underwent baseline and post-chemotherapy conventional, diffusion-weighted and dynamic contrast-enhanced MRI. Taking histological response (good response ≥90% necrosis) as the reference standard, various parameters of MRI were compared to it. A tumor was considered ellipsoidal; volume, average tumor plane and its relative value (average tumor plane relative/body surface area) was calculated using the standard formula for ellipse. Receiver operating characteristic curves were generated to assess best threshold and predictability. After deriving thresholds for each parameter in univariable analysis, multivariable analysis was carried out. Both pre-and post-chemotherapy absolute and relative-size parameters correlated well with necrosis. Apparent diffusion coefficient did not correlate with necrosis; however, on adjusting for volume, significant correlation was found. Thus, we could derive a new parameter: diffusion per unit volume. In osteosarcoma, chemotherapy response can be predicted and evaluated by conventional and diffusion-weighted MRI early in the disease course and it correlates well with necrosis. Further, newly derived parameter diffusion per unit volume appears to be a sensitive substitute for response evaluation in osteosarcoma.
Store-operate-coherence-on-value
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Dong; Heidelberger, Philip; Kumar, Sameer
A system, method and computer program product for performing various store-operate instructions in a parallel computing environment that includes a plurality of processors and at least one cache memory device. A queue in the system receives, from a processor, a store-operate instruction that specifies under which condition a cache coherence operation is to be invoked. A hardware unit in the system runs the received store-operate instruction. The hardware unit evaluates whether a result of the running the received store-operate instruction satisfies the condition. The hardware unit invokes a cache coherence operation on a cache memory address associated with the receivedmore » store-operate instruction if the result satisfies the condition. Otherwise, the hardware unit does not invoke the cache coherence operation on the cache memory device.« less
Does "smoker's paradox" exist in clopidogrel-treated Turkish patients with acute coronary syndrome.
Edem, Efe; Kirdök, Ali Hikmet; Kınay, Ahmet Ozan; Tekin, Ümit İlker; Taş, Sedat; Alpaslan, Erkan; Pabuccu, Mustafa Türker; Akdeniz, Bahri
2016-01-01
Previously conducted studies revealed that smoking enhanced the efficacy of clopidogrel by increasing formation of the active metabolite (AM) from the prodrug through induction of the cytochrome CYP1A2. The expression of cytochrome enzymes depends on genotype and no data exists in literature conducted in Turkish patients comparing the clopidogrel responsiveness between active smokers and non-active smokers treated with clopidogrel. In this study, our aim was to investigate the clopidogrel responsiveness in clopidogrel-treated Turkish acute coronary syndrome (ACS) patients according to their smoking status. We retrospectively enrolled 258 patients who were hospitalized due to ACS. Clinical variables of the patients, especially smoking status were recorded. Clopidogrel resistance was evaluated by using adenosine diphosphate (ADP) induced platelet aggregometry. Clopidogrel resistance was detected as a change in maximal aggregation ≤20% from baseline. A total of 139 patients were active smokers while 12 were former smokers. 107 patients did not have a history of smoking. Ten of the smokers were hyporesponsive to clopidogrel, whereas 36 of non-smokers were hyporesponsive to clopidogrel (p < 0.001). Receiver-operating characteristic curve analysis demonstrated that Au-min value >612.5 predicted the clopidogrel resistance with a sensitivity of 60% (OR: 100.65, %95 CI = 19.996-506.615 p < 0.001). Results of this study demonstrated that ADP responses were lower in smokers receiving clopidogrel and aspirin than in non-smokers receiving the same drug regimen. This finding indicates that smoking was related to an enhanced clopidogrel responsiveness in Turkish patients hospitalized due to ACS, suggesting that "smoker's paradox" probably exists in Turkish ACS patients.
Enhanced optical discrimination system based on switchable retroreflective films
NASA Astrophysics Data System (ADS)
Schultz, Phillip; Heikenfeld, Jason
2016-04-01
Reported herein is the design, characterization, and demonstration of a laser interrogation and response optical discrimination system based on large-area corner-cube retroreflective films. The switchable retroreflective films use light-scattering liquid crystal to modulate retroreflected intensity. The system can operate with multiple wavelengths (visible to infrared) and includes variable divergence optics for irradiance adjustments and ease of system alignment. The electronic receiver and switchable retroreflector offer low-power operation (<4 mW standby) on coin cell batteries with rapid interrogation to retroreflected signal reception response times (<15 ms). The entire switchable retroreflector film is <1 mm thick and is flexible for optimal placement and increased angular response. The system was demonstrated in high ambient lighting conditions (daylight, 18k lux) with a visible 10-mW output 635-nm source out to a distance of 400 m (naked eye detection). Nighttime demonstrations were performed using a 1.5-mW, 850-nm infrared laser diode out to a distance of 400 m using a night vision camera. This system could have tagging and conspicuity applications in commercial or military settings.
A survey of of uses and value of space weather information
NASA Astrophysics Data System (ADS)
Schrijver, C. J.; Rabanal, J.
2013-12-01
We analyze some 2,800 responses to a survey among subscribers of NOAA's Space Weather Prediction Center email services. Interest in, anticipated impacts from, and responses to solar flares, energetic particle events, and geomagnetic storms are quite uniform across societal sectors. Approximately 40% of the respondents expect serious to very serious impacts from space weather events if no action were taken to mitigate or in the absence of adequate space weather information. The impacts of space weather are deemed to be substantially reduced because of the availability of, and the response to, space-weather forecasts and alerts. Space weather information is primarily used as aid to understand anomalies, to implement mitigating strategies designed to avoid impacts on operations, and to prepare for potential contingencies related directly or indirectly to space weather. Current and near-future space-weather conditions are generally highly valued, considered useful, and generally, though not fully, adequate to avoid or mitigate societal impacts (related most frequently to human safety and reliability of operations). We conclude that even among those receiving space weather information, there is considerable uncertainty about how to act on the information provided.
NASA Scientific Data Purchase Project: From Collection to User
NASA Technical Reports Server (NTRS)
Nicholson, Lamar; Policelli, Fritz; Fletcher, Rose
2002-01-01
NASA's Scientific Data Purchase (SDP) project is currently a $70 million operation managed by the Earth Science Applications Directorate at Stennis Space Center. The SDP project was developed in 1997 to purchase scientific data from commercial sources for distribution to NASA Earth science researchers. Our current data holdings include 8TB of remote sensing imagery consisting of 18 products from 4 companies. Our anticipated data volume is 60 TB by 2004, and we will be receiving new data products from several additional companies. Our current system capacity is 24 TB, expandable to 89 TB. Operations include tasking of new data collections, archive ordering, shipment verification, data validation, distribution, metrics, finances, customer feedback, and technical support. The program has been included in the Stennis Space Center Commercial Remote Sensing ISO 9001 registration since its inception. Our operational system includes automatic quality control checks on data received (with MatLab analysis); internally developed, custom Web-based interfaces that tie into commercial-off-the-shelf software; and an integrated relational database that links and tracks all data through operations. We've distributed nearly 1500 datasets, and almost 18,000 data files have been downloaded from our public web site; on a 10-point scale, our customer satisfaction index is 8.32 at a 23% response level. More information about the SDP is available on our Web site.
Li, Wen; Arasu, Vignesh; Newitt, David C.; Jones, Ella F.; Wilmes, Lisa; Gibbs, Jessica; Kornak, John; Joe, Bonnie N.; Esserman, Laura J.; Hylton, Nola M.
2016-01-01
Functional tumor volume (FTV) measurements by dynamic contrast-enhanced magnetic resonance imaging can predict treatment outcomes for women receiving neoadjuvant chemotherapy for breast cancer. Here, we explore whether the contrast thresholds used to define FTV could be adjusted by breast cancer subtype to improve predictive performance. Absolute FTV and percent change in FTV (ΔFTV) at sequential time-points during treatment were calculated and investigated as predictors of pathologic complete response at surgery. Early percent enhancement threshold (PEt) and signal enhancement ratio threshold (SERt) were varied. The predictive performance of resulting FTV predictors was evaluated using the area under the receiver operating characteristic curve. A total number of 116 patients were studied both as a full cohort and in the following groups defined by hormone receptor (HR) and HER2 receptor subtype: 45 HR+/HER2−, 39 HER2+, and 30 triple negatives. High AUCs were found at different ranges of PEt and SERt levels in different subtypes. Findings from this study suggest that the predictive performance to treatment response by MRI varies by contrast thresholds, and that pathologic complete response prediction may be improved through subtype-specific contrast enhancement thresholds. A validation study is underway with a larger patient population. PMID:28066808
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1999-03-01
The US Department of Energy (DOE), prepared a draft Supplement Analysis (SA) for Continued Operation of Lawrence Livermore National Laboratory (LLNL) and Sandia National Laboratories, Livermore (SNL-L), in accordance with DOE`s requirements for implementation of the National Environmental Policy Act of 1969 (NEPA) (10 Code of Federal Regulations [CFR] Part 1021.314). It considers whether the Final Environmental Impact Statement and Environmental Impact Report for Continued Operation of Lawrence Livermore National Laboratory and Sandia National Laboratories, Livermore (1992 EIS/EIR) should be supplement3ed, whether a new environmental impact statement (EIS) should be prepared, or no further NEPA documentation is required. The SAmore » examines the current project and program plans and proposals for LLNL and SNL-L, operations to identify new or modified projects or operations or new information for the period from 1998 to 2002 that was not considered in the 1992 EIS/EIR. When such changes, modifications, and information are identified, they are examined to determine whether they could be considered substantial or significant in reference to the 1992 proposed action and the 1993 Record of Decision (ROD). DOE released the draft SA to the public to obtain stakeholder comments and to consider those comments in the preparation of the final SA. DOE distributed copies of the draft SA to those who were known to have an interest in LLNL or SNL-L activities in addition to those who requested a copy. In response to comments received, DOE prepared this Comment Response Document.« less
An effect of loudness of advisory speech on a choice response task
NASA Astrophysics Data System (ADS)
Utsuki, Narisuke; Takeuchi, Yoshinori; Nomiyama, Takenori
1995-03-01
Recent technologies have realized talking advisory/guidance systems in which machines give advice and guidance to operators in speech. However, nonverbal aspects of spoken messages may have significant effects on an operator's behavior. Twelve subjects participated in a TV game-like choice response task where they were asked to choose a 'true' target from three invader-like figures displayed on a CRT screen. The subjects had received a prerecorded advice designating either left, center, or right target that would be true before each choice. The position of the 'true' targets and advice were preprogrammed in pseudorandom sequences. In other words, there was no way for the subjects to predict the 'true' target and there was no relationship between spoken advice and the true target position. The subjects tended to make more choices corresponding to the presented messages when the messages were presented in a louder voice than in a softer voice. Choice response time was significantly shorter when the response was the same as the advice indicated. The shortening of response time was slightly greater when advice was presented in a louder voice. This study demonstrates that spoken advice may result in faster and less deliberate reponses in accordance with the presented messages which are given by talking guidance systems.
Ito, Toshiki; Kurita, Yutaka; Shinbo, Hitoshi; Yasumi, Yasuhiro; Ushiyama, Tomomi
2013-05-01
A 59-year-old woman who identified as a Jehovah's Witness was diagnosed with pheochromocytoma in the left adrenal gland, measuring 11 cm in diameter, during treatment for hypertension. Given her desire to undergo transfusion-less surgery for religious reasons, we obtained fully informed consent and had the patient sign both a transfusion refusal and exemption-from-responsibility certificate and received consent to instead use plasma derivatives, preoperative diluted autologous transfusion and intraoperative salvaged autologous transfusion. To manage anemia and maintain total blood volume, we preoperatively administered erythropoiesis-stimulating agents and alpha 1 blocker, respectively. During the left adrenalectomy, the patient underwent a transfusion of 400 mL of preoperative diluted autologous blood, ultimately receiving no intraoperative salvaged autologous blood. The operation took 4 hours 42 minutes, and the total volume of blood lost was 335 mL. In conclusion, to complete transfusion-less surgery for pheochromocytoma, it is necessary to have the patient sign a generic refusal form for transfusion and exemption-from-responsibility certificate as well as outline via another consent form exactly what sort of transfusion is permitted on a more specific basis. And doctors should become skilled in perioperative management and operative technique for pheochromocytoma and make the best effort by all alternative medical treatment in order to build trust confidence with a patient.
Adaptive frequency-domain equalization in digital coherent optical receivers.
Faruk, Md Saifuddin; Kikuchi, Kazuro
2011-06-20
We propose a novel frequency-domain adaptive equalizer in digital coherent optical receivers, which can reduce computational complexity of the conventional time-domain adaptive equalizer based on finite-impulse-response (FIR) filters. The proposed equalizer can operate on the input sequence sampled by free-running analog-to-digital converters (ADCs) at the rate of two samples per symbol; therefore, the arbitrary initial sampling phase of ADCs can be adjusted so that the best symbol-spaced sequence is produced. The equalizer can also be configured in the butterfly structure, which enables demultiplexing of polarization tributaries apart from equalization of linear transmission impairments. The performance of the proposed equalization scheme is verified by 40-Gbits/s dual-polarization quadrature phase-shift keying (QPSK) transmission experiments.
The ALMA Band 3 (84-116 GHz) receiver production plan
NASA Astrophysics Data System (ADS)
Yeung, Keith; Claude, Stéphane; Loop, David
2008-07-01
The NRC Herzberg Institute of Astrophysics (NRC-HIA) is currently responsible to contribute Band 3 (84-116 GHz) receivers to the international ALMA project - a partnership involving North America, Europe and, now, Asia. Not only are the technical requirements for these receivers far more stringent than those for any existing radio astronomy receivers operating at these frequencies, but the delivery schedule for these receivers is equally challenging. Since the Asian partnership joined the ALMA project in 2006, NRC-HIA has been asked to deliver an additional 11 cartridges, for a total of 73 units. Some of these new cartridges will be used for the ALMA Compact Array (ACA) and others as spares. Moreover, the project has also requested that these additional cartridges be delivered in the same time period as the original 62 units. To meet this requirement, production must increase from the existing rate of one unit every four weeks to one every two, taxing the existing production infrastructure at NRC-HIA. Additional test facilities and human resources must be planned to sustain the required production rate over the next several years. Industrial involvement is one of the important elements in our production plan. In order to supplement the existing human resources at NRC-HIA, we are planning to outsource a number of low-risk and labor-intensive tasks to industry. However, NRC-HIA will retain overall project management responsibility and will conduct all the cartridge integration and acceptance test activities in-house. This paper focuses on the resource estimation, planning and project management required to deliver the Band 3 receivers to the ALMA project on time and on budget.
Ricketts, Emily J; McGuire, Joseph F; Chang, Susanna; Bose, Deepika; Rasch, Madeline M; Woods, Douglas W; Specht, Matthew W; Walkup, John T; Scahill, Lawrence; Wilhelm, Sabine; Peterson, Alan L; Piacentini, John
2018-01-01
This study assessed the psychometric properties of a parent-reported tic severity measure, the Parent Tic Questionnaire (PTQ), and used the scale to establish guidelines for delineating clinically significant tic treatment response. Participants were 126 children ages 9 to 17 who participated in a randomized controlled trial of Comprehensive Behavioral Intervention for Tics (CBIT). Tic severity was assessed using the Yale Global Tic Severity Scale (YGTSS), Hopkins Motor/Vocal Tic Scale (HMVTS) and PTQ; positive treatment response was defined by a score of 1 (very much improved) or 2 (much improved) on the Clinical Global Impressions - Improvement (CGI-I) scale. Cronbach's alpha and intraclass correlations (ICC) assessed internal consistency and test-retest reliability, with correlations evaluating validity. Receiver- and Quality-Receiver Operating Characteristic analyses assessed the efficiency of percent and raw-reduction cutoffs associated with positive treatment response. The PTQ demonstrated good internal consistency (α = 0.80 to 0.86), excellent test-retest reliability (ICC = .84 to .89), good convergent validity with the YGTSS and HM/VTS, and good discriminant validity from hyperactive, obsessive-compulsive, and externalizing (i.e., aggression and rule-breaking) symptoms. A 55% reduction and 10-point decrease in PTQ Total score were optimal for defining positive treatment response. Findings help standardize tic assessment and provide clinicians with greater clarity in determining clinically meaningful tic symptom change during treatment. Copyright © 2017. Published by Elsevier Ltd.
Tixier, Florent; Le Rest, Catherine Cheze; Hatt, Mathieu; Albarghach, Nidal; Pradier, Olivier; Metges, Jean-Philippe; Corcos, Laurent; Visvikis, Dimitris
2011-03-01
(18)F-FDG PET is often used in clinical routine for diagnosis, staging, and response to therapy assessment or prediction. The standardized uptake value (SUV) in the primary or regional area is the most common quantitative measurement derived from PET images used for those purposes. The aim of this study was to propose and evaluate new parameters obtained by textural analysis of baseline PET scans for the prediction of therapy response in esophageal cancer. Forty-one patients with newly diagnosed esophageal cancer treated with combined radiochemotherapy were included in this study. All patients underwent pretreatment whole-body (18)F-FDG PET. Patients were treated with radiotherapy and alkylatinlike agents (5-fluorouracil-cisplatin or 5-fluorouracil-carboplatin). Patients were classified as nonresponders (progressive or stable disease), partial responders, or complete responders according to the Response Evaluation Criteria in Solid Tumors. Different image-derived indices obtained from the pretreatment PET tumor images were considered. These included usual indices such as maximum SUV, peak SUV, and mean SUV and a total of 38 features (such as entropy, size, and magnitude of local and global heterogeneous and homogeneous tumor regions) extracted from the 5 different textures considered. The capacity of each parameter to classify patients with respect to response to therapy was assessed using the Kruskal-Wallis test (P < 0.05). Specificity and sensitivity (including 95% confidence intervals) for each of the studied parameters were derived using receiver-operating-characteristic curves. Relationships between pairs of voxels, characterizing local tumor metabolic nonuniformities, were able to significantly differentiate all 3 patient groups (P < 0.0006). Regional measures of tumor characteristics, such as size of nonuniform metabolic regions and corresponding intensity nonuniformities within these regions, were also significant factors for prediction of response to therapy (P = 0.0002). Receiver-operating-characteristic curve analysis showed that tumor textural analysis can provide nonresponder, partial-responder, and complete-responder patient identification with higher sensitivity (76%-92%) than any SUV measurement. Textural features of tumor metabolic distribution extracted from baseline (18)F-FDG PET images allow for the best stratification of esophageal carcinoma patients in the context of therapy-response prediction.
To, Masako; Tajima, Makoto; Ogawa, Cyuhei; Otomo, Mamoru; Suzuki, Naohito; Sano, Yasuyuki
2002-01-01
Stimulation to bronchial mucosa is one of the major risk factor of asthma attack. When patients receive surgical intervention and general anesthesia, they are always exposed to stimulation to bronchial mucosa. Prevention method of bronchial asthma attack during surgical intervention is not established yet. We investigated that clinical course of patients with bronchial asthma who received general anesthesia and surgical intervention. Seventy-six patients with bronchial asthma were received general anesthesia and surgical intervention from 1993 to 1998. Twenty-four patients were mild asthmatic patients, 39 were moderate asthmatic patients and 13 were severe asthmatic patients. Preoperative treatment for preventing asthma attack was as follows; Eight patients were given intravenous infusion of aminophylline before operation. Fifty-two patients were given intravenous infusion of aminophylline and hydrocortisone before operation. Three patients were given intravenous infusion of hydrocortisone for consecutive 3 days before operation. Thirteen patients were given no treatment for preventing asthma attack. One patient was suffered from asthma attack during operation. She was given no preventing treatment for asthma attack before operation. Three patients were suffered from asthma attack after operation. No wound dehiscence was observed in all patients. To prevent asthma attack during operation, intravenous infusion of steroid before operation is recommended, when patients with asthma receive general anesthesia and surgical intervention.
Eddy current inspection tool. [Patent application
Petrini, R.R.; Van Lue, D.F.
1980-10-29
A miniaturized inspection tool, for testing and inspection of metal objects in locations with difficult accessibility, which comprises eddy current sensing equipment with a probe coil, and associated coaxial coil cable, oil energizing means, and circuit means responsive to impedance changes in the coil as effected by induced eddy currents in a test object to produce a data output signal proportional to such changes. The coil and cable are slideably received in the utility channel of the flexible insertion tube of a fiberoptic scope. The scope is provided with light transmitting and receiving fiberoptics for viewing through the flexible tube, and articulation means for articulating the distal end of the tube and permitting close control of coil placement relative to a test object. The eddy current sensing equipment includes a tone generator for generating audible signals responsive to the data output signal. In one selected mode of operation, the tone generator responsive to the output signal above a selected level generates a constant single frequency tone for signalling detection of a discontinuity and, in a second selected mode, generates a tone whose frequency is proportional to the difference between the output signal and a predetermined selected threshold level.
Rodríguez-Álvarez, María Xosé; Roca-Pardiñas, Javier; Cadarso-Suárez, Carmen; Tahoces, Pablo G
2018-03-01
Prior to using a diagnostic test in a routine clinical setting, the rigorous evaluation of its diagnostic accuracy is essential. The receiver-operating characteristic curve is the measure of accuracy most widely used for continuous diagnostic tests. However, the possible impact of extra information about the patient (or even the environment) on diagnostic accuracy also needs to be assessed. In this paper, we focus on an estimator for the covariate-specific receiver-operating characteristic curve based on direct regression modelling and nonparametric smoothing techniques. This approach defines the class of generalised additive models for the receiver-operating characteristic curve. The main aim of the paper is to offer new inferential procedures for testing the effect of covariates on the conditional receiver-operating characteristic curve within the above-mentioned class. Specifically, two different bootstrap-based tests are suggested to check (a) the possible effect of continuous covariates on the receiver-operating characteristic curve and (b) the presence of factor-by-curve interaction terms. The validity of the proposed bootstrap-based procedures is supported by simulations. To facilitate the application of these new procedures in practice, an R-package, known as npROCRegression, is provided and briefly described. Finally, data derived from a computer-aided diagnostic system for the automatic detection of tumour masses in breast cancer is analysed.
Science in Emergency Response at CDC: Structure and Functions.
Iskander, John; Rose, Dale A; Ghiya, Neelam D
2017-09-01
Recent high-profile activations of the US Centers for Disease Control and Prevention (CDC) Emergency Operations Center (EOC) include responses to the West African Ebola and Zika virus epidemics. Within the EOC, emergency responses are organized according to the Incident Management System, which provides a standardized structure and chain of command, regardless of whether the EOC activation occurs in response to an outbreak, natural disaster, or other type of public health emergency. By embedding key scientific roles, such as the associate director for science, and functions within a Scientific Response Section, the current CDC emergency response structure ensures that both urgent and important science issues receive needed attention. Key functions during emergency responses include internal coordination of scientific work, data management, information dissemination, and scientific publication. We describe a case example involving the ongoing Zika virus response that demonstrates how the scientific response structure can be used to rapidly produce high-quality science needed to answer urgent public health questions and guide policy. Within the context of emergency response, longer-term priorities at CDC include both streamlining administrative requirements and funding mechanisms for scientific research.
Shappell, Claire; Snyder, Ashley; Edelson, Dana P; Churpek, Matthew M
2018-07-01
Despite wide adoption of rapid response teams across the United States, predictors of in-hospital mortality for patients receiving rapid response team calls are poorly characterized. Identification of patients at high risk of death during hospitalization could improve triage to intensive care units and prompt timely reevaluations of goals of care. We sought to identify predictors of in-hospital mortality in patients who are subjects of rapid response team calls and to develop and validate a predictive model for death after rapid response team call. Analysis of data from the national Get with the Guidelines-Medical Emergency Team event registry. Two-hundred seventy four hospitals participating in Get with the Guidelines-Medical Emergency Team from June 2005 to February 2015. 282,710 hospitalized adults on surgical or medical wards who were subjects of a rapid response team call. None. The primary outcome was death during hospitalization; candidate predictors included patient demographic- and event-level characteristics. Patients who died after rapid response team were older (median age 72 vs 66 yr), were more likely to be admitted for noncardiac medical illness (70% vs 58%), and had greater median length of stay prior to rapid response team (81 vs 47 hr) (p < 0.001 for all comparisons). The prediction model had an area under the receiver operating characteristic curve of 0.78 (95% CI, 0.78-0.79), with systolic blood pressure, time since admission, and respiratory rate being the most important variables. Patients who die following rapid response team calls differ significantly from surviving peers. Recognition of these factors could improve postrapid response team triage decisions and prompt timely goals of care discussions.
Send-side matching of data communications messages
Archer, Charles J.; Blocksome, Michael A.; Ratterman, Joseph D.; Smith, Brian E.
2014-06-17
Send-side matching of data communications messages in a distributed computing system comprising a plurality of compute nodes, including: issuing by a receiving node to source nodes a receive message that specifies receipt of a single message to be sent from any source node, the receive message including message matching information, a specification of a hardware-level mutual exclusion device, and an identification of a receive buffer; matching by two or more of the source nodes the receive message with pending send messages in the two or more source nodes; operating by one of the source nodes having a matching send message the mutual exclusion device, excluding messages from other source nodes with matching send messages and identifying to the receiving node the source node operating the mutual exclusion device; and sending to the receiving node from the source node operating the mutual exclusion device a matched pending message.
NASA Astrophysics Data System (ADS)
Wang, Qingjie; Xin, Jingmin; Wu, Jiayi; Zheng, Nanning
2017-03-01
Microaneurysms are the earliest clinic signs of diabetic retinopathy, and many algorithms were developed for the automatic classification of these specific pathology. However, the imbalanced class distribution of dataset usually causes the classification accuracy of true microaneurysms be low. Therefore, by combining the borderline synthetic minority over-sampling technique (BSMOTE) with the data cleaning techniques such as Tomek links and Wilson's edited nearest neighbor rule (ENN) to resample the imbalanced dataset, we propose two new support vector machine (SVM) classification algorithms for the microaneurysms. The proposed BSMOTE-Tomek and BSMOTE-ENN algorithms consist of: 1) the adaptive synthesis of the minority samples in the neighborhood of the borderline, and 2) the remove of redundant training samples for improving the efficiency of data utilization. Moreover, the modified SVM classifier with probabilistic outputs is used to divide the microaneurysm candidates into two groups: true microaneurysms and false microaneurysms. The experiments with a public microaneurysms database shows that the proposed algorithms have better classification performance including the receiver operating characteristic (ROC) curve and the free-response receiver operating characteristic (FROC) curve.
Method and System for Name Resolution Across Heterogeneous Architectures
NASA Technical Reports Server (NTRS)
Sevilla, Spencer (Inventor); Garcia-Luna-Aceves, Jose J. (Inventor); Mahadevan, Priya (Inventor)
2018-01-01
One embodiment of the present invention provides a system for resolving a name request in a network comprising a plurality of groups that use different name-resolution schemes. During operation, the system receives, at a first group, the name request; identifies a parent group of the first group, which is a member of the parent group; and in response to failing to resolve the name request within the first group, forwards the name request to the identified parent group.
NASA Technical Reports Server (NTRS)
Carreno, Victor A.
2015-01-01
Pair-wise Trajectory Management (PTM) is a cockpit based delegated responsibility separation standard. When an air traffic service provider gives a PTM clearance to an aircraft and the flight crew accepts the clearance, the flight crew will maintain spacing and separation from a designated aircraft. A PTM along track algorithm will receive state information from the designated aircraft and from the own ship to produce speed guidance for the flight crew to maintain spacing and separation
COMMUNITY MENTAL HEALTH SERVICES ACT—Five Years of Operation Under the California Law
Rudin, Edward; McInnes, Robert S.
1963-01-01
The Short-Doyle program represents a small part of the needed response to the base problem of mental illness. However, in the five years since the signing of the original bill, programs receiving aid under the Short-Doyle Act for Community Mental Health Services have made impressive steps toward meeting the need for community mental health services. They have done so under local auspices and working closely with general health and medical programs available locally. PMID:13982995
Scuderi, Maria Grazia; Magro, Gaetano; Di Cataldo, Andrea; Pesce, Antonino; Scalora, Luisa; Vecchio, Giada Maria; Portale, Rosanna; Di Benedetto, Vincenzo; Puleo, Stefano
2013-08-01
Neoadjuvant chemotherapy for colorectal liver metastases in adults is responsible for chemotherapy-associated liver injury (CALI), characterized by steatosis, steatohepatitis, and sinusoidal obstruction syndrome. These alterations cause delayed operation to reduce the risk of hemorrhage, portal hypertension, and hepatic failure. Children with hepatic malignancies usually receive neoadjuvant chemotherapy prior to surgery. The aim of this study was to evaluate retrospectively whether the CALI occurs in this pediatric population. This study evaluated patients referred since 1996 for hepatic malignancies who received hepatectomy after chemotherapy. Liver resection material was reviewed, in order to investigate the presence of morphological changes compatible with the CALI in the peritumoral hepatic tissue. Twelve patients were recruited. All patients satisfied the inclusion criteria except one who did not receive neoadjuvant chemotherapy. Eleven children underwent surgery 1 month after the last chemotherapy cycle. All are alive disease-free. Histological examination of specimen revealed only mild changes such as diffuse swelling of hepatocytes and focal, mild portal inflammation. Severe hepatic changes such as steatosis, necrosis, or fibrosis were not identified. CALI-related morphological changes were not found in our patients. The absence of the CALI could be attributed to the younger age of patients (possible different response to stress) and/or to the different chemotherapy schedules compared to those in use for adults patients.
Characterization of Advanced Avalanche Photodiodes for Water Vapor Lidar Receivers
NASA Technical Reports Server (NTRS)
Refaat, Tamer F.; Halama, Gary E.; DeYoung, Russell J.
2000-01-01
Development of advanced differential absorption lidar (DIAL) receivers is very important to increase the accuracy of atmospheric water vapor measurements. A major component of such receivers is the optical detector. In the near-infrared wavelength range avalanche photodiodes (APD's) are the best choice for higher signal-to-noise ratio, where there are many water vapor absorption lines. In this study, characterization experiments were performed to evaluate a group of silicon-based APD's. The APD's have different structures representative of different manufacturers. The experiments include setups to calibrate these devices, as well as characterization of the effects of voltage bias and temperature on the responsivity, surface scans, noise measurements, and frequency response measurements. For each experiment, the setup, procedure, data analysis, and results are given and discussed. This research was done to choose a suitable APD detector for the development of an advanced atmospheric water vapor differential absorption lidar detection system operating either at 720, 820, or 940 nm. The results point out the benefits of using the super low ionization ratio (SLIK) structure APD for its lower noise-equivalent power, which was found to be on the order of 2 to 4 fW/Hz(sup (1/2)), with an appropriate optical system and electronics. The water vapor detection systems signal-to-noise ratio will increase by a factor of 10.
Clock distribution system for digital computers
Wyman, Robert H.; Loomis, Jr., Herschel H.
1981-01-01
Apparatus for eliminating, in each clock distribution amplifier of a clock distribution system, sequential pulse catch-up error due to one pulse "overtaking" a prior clock pulse. The apparatus includes timing means to produce a periodic electromagnetic signal with a fundamental frequency having a fundamental frequency component V'.sub.01 (t); an array of N signal characteristic detector means, with detector means No. 1 receiving the timing means signal and producing a change-of-state signal V.sub.1 (t) in response to receipt of a signal above a predetermined threshold; N substantially identical filter means, one filter means being operatively associated with each detector means, for receiving the change-of-state signal V.sub.n (t) and producing a modified change-of-state signal V'.sub.n (t) (n=1, . . . , N) having a fundamental frequency component that is substantially proportional to V'.sub.01 (t-.theta..sub.n (t) with a cumulative phase shift .theta..sub.n (t) having a time derivative that may be made uniformly and arbitrarily small; and with the detector means n+1 (1.ltoreq.n
Furukawa, Emi; Alsop, Brent; Sowerby, Paula; Jensen, Stephanie; Tripp, Gail
2017-03-01
The behavioral sensitivity of children with ADHD to punishment has received limited theoretical and experimental attention. This study evaluated the effects of punishment on the response allocation of children with ADHD and typically developing children. Two hundred and ten children, 145 diagnosed with ADHD, completed an operant task in which they chose between playing two simultaneously available games. Reward was arranged symmetrically across the games under concurrent variable interval schedules. Asymmetric punishment schedules were superimposed; responses on one game were punished four times as often as responses on the other. Both groups allocated more of their responses to the less frequently punished alternative. Response bias increased significantly in the ADHD group during later trials, resulting in missed reward trials and reduced earnings. Punishment exerted greater control over the response allocation of children with ADHD with increased time on task. Children with ADHD appear more sensitive to the cumulative effects of punishment than typically developing children. © 2016 Association for Child and Adolescent Mental Health.
Concentrating Solar Power Projects - Kimberlina Solar Thermal Power Plant |
MW Gross: 5.0 MW Status: Currently Non-Operational Start Year: 2008 Do you have more information , corrections, or comments? Background Technology: Linear Fresnel reflector Status: Currently Non-Operational Manufacturer: Ausra Receiver Manufacturer : Ausra Receiver Type: Non-evacuated Receiver Length: 385 m Heat
ROC curve analyses of eyewitness identification decisions: An analysis of the recent debate.
Rotello, Caren M; Chen, Tina
2016-01-01
How should the accuracy of eyewitness identification decisions be measured, so that best practices for identification can be determined? This fundamental question is under intense debate. One side advocates for continued use of a traditional measure of identification accuracy, known as the diagnosticity ratio , whereas the other side argues that receiver operating characteristic curves (ROCs) should be used instead because diagnosticity is confounded with response bias. Diagnosticity proponents have offered several criticisms of ROCs, which we show are either false or irrelevant to the assessment of eyewitness accuracy. We also show that, like diagnosticity, Bayesian measures of identification accuracy confound response bias with witnesses' ability to discriminate guilty from innocent suspects. ROCs are an essential tool for distinguishing memory-based processes from decisional aspects of a response; simulations of different possible identification tasks and response strategies show that they offer important constraints on theory development.
Ono, Yuichi; Hayakawa, Mineji; Iijima, Hiroaki; Maekawa, Kunihiko; Kodate, Akira; Sadamoto, Yoshihiro; Mizugaki, Asumi; Murakami, Hiromoto; Katabami, Kenichi; Sawamura, Atsushi; Gando, Satoshi
2016-10-01
It is well established that the period of time between a call being made to emergency medical services (EMS) and the time at which the EMS arrive at the scene (i.e. the response time) affects survival outcomes in patients who experience out-of-hospital cardiac arrest (OHCA). However, the relationship between the response time and favourable neurological outcomes remains unclear. We therefore aimed to determine a response time threshold in patients with bystander-witnessed OHCA that is associated with positive neurological outcomes and to assess the relationship between the response time and neurological outcomes in patients with OHCA. This study was a retrospective, observational analysis of data from 204,277 episodes of bystander-witnessed OHCA between 2006 and 2012 in Japan. We used classification and regression trees (CARTs) and receiver operating characteristic (ROC) curve analyses to determine the threshold of response time associated with favourable neurological outcomes (Cerebral Performance Category 1 or 2) 1 month after cardiac arrest. Both CARTs and ROC analyses indicated that a threshold of 6.5min was associated with improved neurological outcomes in all bystander-witnessed OHCA events of cardiac origin. Furthermore, bystander cardiopulmonary resuscitation (CPR) prolonged the threshold of response time by 1min (up to 7.5min). The adjusted odds ratio for favourable neurological outcomes in patients with OHCA who received care within ≤6.5min was 1.935 (95% confidential interval: 1.834-2.041, P<0.001). A response time of ≤6.5min was closely associated with favourable neurological outcomes in all bystander-witnessed patients with OHCA. Bystander CPR prolonged the response time threshold by 1min. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Morey, L C; Lanier, V W
1998-09-01
The characteristics of six different indicators of response distortion on the Personality Assessment Inventory (PAI; Morey, 1991) were evaluated by having college students complete the PAI under positive impression management, malingering, and honest responding conditions. The six indicators were the PAI Positive Impression (PIM) and Negative Impression (NIM) scales, the Malingering and Defensiveness Indexes, and two discriminant functions, one developed by Cashel and the other by Rogers. Protocols of students asked to malinger were compared with those of actual clinical patients, while protocols of students asked to manage their impression in a positive direction were compared with those of students asked to respond honestly. Comparisons between groups were accomplished through the examination of effect sizes and receiver operating characteristic (ROC) curves. All six indicators demonstrated the ability to distinguish between actual and feigned responding. The Rogers function was particularly effective in identifying malingering. The Cashel function was less effective than other measures in identifying positive impression management, although it appears to also have promise as an indicator of malingering.
Comparison of quality of life outcomes following different mastoid surgery techniques.
Joseph, J; Miles, A; Ifeacho, S; Patel, N; Shaida, A; Gatland, D; Watters, G; Kiverniti, E
2015-09-01
Mastoid surgery carried out to treat chronic otitis media can lead to improvement in objective and subjective measures post-operatively. This study investigated the subjective change in quality of life using the Glasgow Benefit Inventory relative to the type of mastoid surgery undertaken. A retrospective multicentre postal survey of 157 patients who underwent mastoid surgery from 2008 to 2012 was conducted. Eighty-three questionnaire responses were received from patients who underwent surgery at one of three different hospitals (a response rate of 53 per cent). Fifty-seven per cent of patients had a Glasgow Benefit Inventory score of 0, indicating no change in quality of life post-operatively. Thirty-five per cent scored over 50, indicating significant improvement. The only significant difference found was that women fared worse after surgery than men. The choice of mastoid surgery technique should be determined by clinical need and surgeon preference. There is no improvement in quality of life for most patients following mastoid surgery.
Mouret-Reynier, Marie-Ange; Savoye, Aude-Marie; Abrial, Catherine; Kwiatkowski, Fabrice; Garbar, Christian; DuBray-Longeras, Pascale; Eymard, Jean-Christophe; Lebouedec, Guillaume; Vanpraagh, Isabelle; Penault-Llorca, Frederique; Chollet, Philippe; Cure, Hervé
2015-01-01
Background. Neoadjuvant treatment provides a unique opportunity to evaluate individual tumor sensitivity. This study evaluated whether a response-guided strategy could improve clinical outcome compared with a standard treatment. Methods. Overall, 264 previously untreated stage II–III operable breast cancer patients were randomized to receive either standard treatment (arm A, n = 131), consisting of fluorouracil, epirubicin, and cyclophosphamide (FEC100: 500, 100, and 500 mg/m2, respectively, for 3 cycles) followed by docetaxel (100 mg/m2 for 3 cycles), or adapted treatment (arm B, n = 133), beginning with 2 cycles of FEC100 and switching to docetaxel if tumor size decreased by <30% after 2 cycles or <50% after 4 cycles of FEC100 (ultrasound assessments according to World Health Organization criteria). Otherwise, FEC100 was given for six cycles before surgery. Intent-to-treat analysis was performed. Results. Similar results were observed for clinical response (objective response was 54% vs 56%, p = .18), breast conservation surgery (BCS; 67% vs 68%, p = .97), and pathological complete response rate (Chevallier classification: 14% vs 11%, p = .68; Statloff classification: 16% vs 13%, p = .82) between arms A and B. Similar toxicities were observed, even with unbalanced numbers of FEC100 and docetaxel courses. Conclusion. Adapted and standard treatments had similar results in terms of tumor response, BCS rate, and tolerability. Further survival outcome data are expected. PMID:25637380
Superconductive hot-electron-bolometer mixer receiver for 800-GHz operation
NASA Astrophysics Data System (ADS)
Kawamura, J.; Blundell, R.; Tong, C.-Y. E.; Papa, D. C.; Hunter, T. R.; Paine, S. N.; Patt, F.; Gol'Tsman, G.; Cherednichenko, S.; Voronov, B.; Gershenzon, E.
2000-04-01
In this paper, we describe a superconductive hot-electron-bolometer mixer receiver designed to operate in the partially transmissive 350-μm atmospheric window. The receiver employs an NbN thin-film microbridge as the mixer element, in which the main cooling mechanism of the hot electrons is through electron-phonon interaction. At a local-oscillator frequency of 808 GHz, the measured double-sideband receiver noise temperature is Trx=970 K, across a 1-GHz intermediate-frequency bandwidth centered at 1.8 GHz. We have measured the linearity of the receiver and the amount of local-oscillator power incident on the mixer for optimal operation, which is PLO ≈ 1 microwatt. This receiver was used in making observations as a facility instrument at the Heinrich Hertz Telescope, Mt. Graham, AZ, during the 1998-1999 winter observing season.
Negahban, Hossein; Behtash, Zeinab; Sohani, Soheil Mansour; Salehi, Reza
2015-01-01
To identify the ability of the Persian-version of the Shoulder Pain and Disability Index (SPADI) and the Disabilities of the Arm, Shoulder, and Hand (DASH) to detect changes in shoulder function following physiotherapy intervention (i.e. responsiveness) and to determine the change score that indicates a meaningful change in functional ability of the patient (i.e. Minimally Clinically Important Difference (MCID)). A convenient sample of 200 Persian-speaking patients with shoulder disorders completed the SPADI and the DASH at baseline and then again 4 weeks after physiotherapy intervention. Furthermore, patients were asked to rate their global rating of shoulder function at follow-up. The responsiveness was evaluated using two methods: the receiver operating characteristics (ROC) method and the correlation analysis. Two useful statistics extracted from the ROC method are the area under curve (AUC) and the optimal cutoff point called as MCID. Both the SPADI and the DASH showed the AUC of greater than 0.70 (AUC ranges = 0.77-0.82). The best cutoff points (or change scores) for the SPADI-total, SPADI-pain, SPADI-disability and the DASH were 14.88, 26.36, 23.86, and 25.41, respectively. Additionally, moderate to good correlations (Gamma = -0.51 to -0.58) were found between the changes in SPADI/DASH and changes in global rating scale. The Persian SPADI and DASH have adequate responsiveness to clinical changes in patients with shoulder disorders. Moreover, the MCIDs obtained in this study will help the clinicians and researchers to determine if a Persian-speaking patient with shoulder disorder has experienced a true change following a physiotherapy intervention. Implications for Rehabilitation Responsiveness was evaluated using two methods; the receiver operating characteristics (ROC) method and the correlation analysis. The Persian SPADI and DASH can be used as two responsive instruments in both clinical practice and research settings. The MCIDs of 14.88 and 25.41 points obtained for the SPADI-total and DASH indicated that the change scores of at least 14.88 points on the SPADI-total and 25.41 points on the DASH is necessary to certain that a true change has occurred following a physiotherapy intervention.
Lightner, Amy L; Raffals, Laura E; Mathis, Kellie L; Cima, Robert R; Tse, Chung Sang; Pemberton, John H; Dozois, Eric J; Loftus, Edward V
2017-02-01
Vedolizumab was recently approved by the Food and Drug Administration for the treatment of moderate to severe ulcerative colitis [UC] and Crohn's disease [CD]. No study to date has examined the rate of postoperative infectious complications among patients who received vedolizumab in the perioperative period. We sought to determine the 30-day postoperative infectious complication rate among inflammatory bowel disease [IBD] patients who received vedolizumab within 12 weeks of an abdominal operation as compared to patients who received tumour necrosis factor α [TNFα] inhibitors or no biological therapy. A retrospective chart review between May 1, 2014 and December 31, 2015 of adult IBD patients who underwent an abdominal operation was performed. The study cohort comprised patients who received vedolizumab within 12 weeks of their abdominal operation and the control cohorts were patients who received TNFα inhibitors or no biological therapy. In total, 94 patients received vedolizumab within 12 weeks of an abdominal operation. Fifty experienced postoperative complications [53%], 35 of which were surgical site infections [SSIs] [36%]. The vedolizumab group experienced significantly higher rates of any postoperative infection [53% vs 33% anti-TNF and 28% non-biologics; p<0.001] and SSI [37% vs 10% and 13%; p<0.001]. On univariate and multivariate analysis, exposure to vedolizumab remained a significant predictor of postoperative SSI [p<0.001]. Thirty-seven per cent of IBD patients who received vedolizumab within 30 days of a major abdominal operation experienced a 30-day postoperative SSI, significantly higher than patients receiving TNFα inhibitors or no biological therapy. Vedolizumab within 12 weeks of surgery remained the only predictor of 30-day postoperative SSI on multivariate analysis. Copyright © 2016 European Crohn’s and Colitis Organisation (ECCO). Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kutscher, C.; Burkholder, F.; Stynes, K.
2010-10-01
The overall efficiency of a parabolic trough collector is a function of both the fraction of direct normal radiation absorbed by the receiver (the optical efficiency) and the heat lost to the environment when the receiver is at operating temperature. The overall efficiency can be determined by testing the collector under actual operating conditions or by separately measuring these two components. This paper describes how outdoor measurement of the optical efficiency is combined with laboratory measurements of receiver heat loss to obtain an overall efficiency curve. Further, it presents a new way to plot efficiency that is more robust overmore » a range of receiver operating temperatures.« less
The impact of a large-scale power outage on hemodialysis center operations.
Abir, Mahshid; Jan, Sophia; Jubelt, Lindsay; Merchant, Raina M; Lurie, Nicole
2013-12-01
On June 29, 2012, mid-Atlantic storms resulted in a large-scale power outage affecting up to three million people across multiple (US) states. Hemodialysis centers are dependent on electricity to provide dialysis care to end-stage renal disease patients. The objective of this study was to determine how the power outage impacted operations in a sample of hemodialysis centers in the impacted regions. The sample consisted of all hemodialysis centers located in the District of Columbia and a total of five counties with the largest power losses in West Virginia, Virginia, and Maryland. A semi-structured interview guide was developed, and the charge nurse or supervisor in each facility was interviewed. The survey questions addressed whether their centers lost power, if so, for how long, where their patients received dialysis, whether their centers had backup generators, and if so, whether they had any problems operating them, and whether their center received patients from other centers if they had power. Calls were placed to 90 dialysis centers in the sampled areas and a 90% response rate was achieved. Overall, hemodialysis operations at approximately 30% (n = 24) of the centers queried were impacted by the power outage. Of the 36 centers that lost power, 31% (n = 11) referred their patients to other dialysis centers, 22% (n = 8) accommodated their patients during a later shift or on a different day; the rest of the centers either experienced brief power outages that did not affect operations or experienced a power outage on days that the center is usually closed. Some centers in the study cohort reported receiving patients from other centers for dialysis 33% (n = 27). Thirty-two percent (n = 26) of the centers queried had backup generators on site. Eleven percent (n = 4) of the centers experiencing power outages reported that backup generators were brought in by their parent companies. Comprehensive emergency planning for dialysis centers should include provisions for having backup generators on site, having plans in place for the timely delivery of a generator during a power outage, or having predesignated backup dialysis centers for patients to receive dialysis during emergencies. Most dialysis centers surveyed in this study were able to sustain continuity of care by implementing such pre-existing emergency plans.
Kongara, K; Chambers, J P; Johnson, C B; Dukkipati, V S R
2013-11-01
To compare the effects of pre-operatively administered tramadol with those of morphine on electroencephalographic responses to surgery and post-operative pain in dogs undergoing castration. Dogs undergoing castration were treated with either pre-operative morphine (0.5 mg/kg S/C, n = 8) or tramadol (3 mg/kg S/C, n = 8). All dogs also received 0.05 mg/kg acepromazine and 0.04 mg/kg atropine S/C in addition to the test analgesic. Anaesthesia was induced with thiopentone administered I/V to effect and maintained with halothane in oxygen. Respiratory rate, heart rate, end-tidal halothane tension (EtHal) and end-tidal CO2 tension (EtCO2) were monitored throughout surgery. Electroencephalograms (EEG) were recorded continuously using a three electrode montage. Median frequency (F50), total power (Ptot) and 95% spectral edge frequency (F95) derived from EEG power spectra recorded before skin incision (baseline) were compared with those recorded during ligation of the spermatic cords of both testicles. Post-operatively, pain was assessed after 1, 3, 6 and 9 h using the short form of the Glasgow composite measure pain scale (CMPS-SF). Dogs premedicated with tramadol had higher mean F50 (12.2 (SD 0.2) Hz) and lower Ptot (130.39 (SD 12.1) µv(2)) compared with those premedicated with morphine (11.5 (SD 0.2) Hz and 161.8 (SD 15.1) µv(2), respectively; p<0.05) during ligation of testicle 1. There were no differences in EEG responses between the two treatment groups during ligation of testicle 2 (p>0.05). The F95 of the EEG did not differ between the two groups during the ligation of either testicle (p > 0.05). Post-operatively, no significant differences in the CMPS-SF score were found between animals premedicated with tramadol and morphine at any time during the post-operative period. No dog required rescue analgesia. Tramadol and morphine administered pre-operatively provided a similar degree of post-operative analgesia in male dogs at the doses tested.
Code of Federal Regulations, 2013 CFR
2013-01-01
... regulation (such as “originating depository financial institution,” “operator,” “originating gateway operator,” “receiving depository financial institution,” “receiving gateway operator,” and “third-party sender”) are... users to a computer server, including specifically a service or system that provides access to the...
Code of Federal Regulations, 2012 CFR
2012-07-01
... regulation (such as “originating depository financial institution,” “operator,” “originating gateway operator,” “receiving depository financial institution,” “receiving gateway operator,” and “third-party sender”) are... users to a computer server, including specifically a service or system that provides access to the...
NASA Technical Reports Server (NTRS)
Sun, Xiaoli; Neumann, Gregory A.; Abshire, James B.; Zuber, Maria T.
2005-01-01
The Mars Orbiter Laser Altimeter not only provides surface topography from the laser pulse time-of-flight, but also two radiometric measurements, the active measurement of transmitted and reflected laser pulse energy, and the passive measurement of reflected solar illumination. The passive radiometry measurement is accomplished in a novel fashion by monitoring the noise density at the output of the photodetector and solving for the amount of background light. The passive radiometry measurements provide images of Mars at 1064-nm wavelength over a 2 nm bandwidth with sub-km spatial resolution and with 2% or better precision under full illumination. We describe in this paper the principle of operation, the receiver mathematical model, its calibration, and performance assessment from sample measurement data.
12. VIEW OF OPERATING ROOMRCA COMMUNICATION REC STATION (THIS ROOM ...
12. VIEW OF OPERATING ROOM-RCA COMMUNICATION REC STATION (THIS ROOM WAS ORIGINALLY A MOTOR GENERATOR FACILITY AND SUPPLIED DC POWER TO AN EARLIER GENERATION OF POINT-TO-POINT RECEIVERS ON SECOND FLOOR). VIEW SHOWS TRANSMITTER CONTROL STATION AND AUDIO CONTROL STATION (LEFT, WATKINS-JOHNSON WJ-8718-23. HP RECEIVERS AND KENWOOD R-5000 COMMUNICATIONS RECEIVERS (220 DEGREES). - Marconi Radio Sites, Receiving, Point Reyes Station, Marin County, CA
Sodium reflux pool-boiler solar receiver on-sun test results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andraka, C E; Moreno, J B; Diver, R B
1992-06-01
The efficient operation of a Stirling engine requires the application of a high heat flux to the relatively small area occupied by the heater head tubes. Previous attempts to couple solar energy to Stirling engines generally involved directly illuminating the heater head tubes with concentrated sunlight. In this study, operation of a 75-kW{sub t} sodium reflux pool-boiler solar receiver has been demonstrated and its performance characterized on Sandia's nominal 75-kW{sub t} parabolic-dish concentrator, using a cold-water gas-gap calorimeter to simulate Stirling engine operation. The pool boiler (and more generally liquid-metal reflux receivers) supplies heat to the engine in the formmore » of latent heat released from condensation of the metal vapor on the heater head tubes. The advantages of the pool boiler include uniform tube temperature, leading to longer life and higher temperature available to the engine, and decoupling of the design of the solar absorber from the engine heater head. The two-phase system allows high input thermal flux, reducing the receiver size and losses, therefore improving system efficiency. The receiver thermal efficiency was about 90% when operated at full power and 800{degree}C. Stable sodium boiling was promoted by the addition of 35 equally spaced artificial cavities in the wetted absorber surface. High incipient boiling superheats following cloud transients were suppressed passively by the addition of small amounts of xenon gas to the receiver volume. Stable boiling without excessive incipient boiling superheats was observed under all operating conditions. The receiver developed a leak during performance evaluation, terminating the testing after accumulating about 50 hours on sun. The receiver design is reported here along with test results including transient operations, steady-state performance evaluation, operation at various temperatures, infrared thermography, x-ray studies of the boiling behavior, and a postmortem analysis.« less
Jahanshahi, Marjan
2013-01-01
Inhibition of inappropriate, habitual or prepotent responses is an essential component of executive control and a cornerstone of self-control. Via the hyperdirect pathway, the subthalamic nucleus (STN) receives inputs from frontal areas involved in inhibition and executive control. Evidence is reviewed from our own work and the literature suggesting that in Parkinson's disease (PD), deep brain stimulation (DBS) of the STN has an impact on executive control during attention-demanding tasks or in situations of conflict when habitual or prepotent responses have to be inhibited. These results support a role for the STN in an inter-related set of processes: switching from automatic to controlled processing, inhibitory and executive control, adjusting response thresholds and influencing speed-accuracy trade-offs. Such STN DBS-induced deficits in inhibitory and executive control may contribute to some of the psychiatric problems experienced by a proportion of operated cases after STN DBS surgery in PD. However, as no direct evidence for such a link is currently available, there is a need to provide direct evidence for such a link between STN DBS-induced deficits in inhibitory and executive control and post-surgical psychiatric complications experienced by operated patients. PMID:24399941
Singhal, Ash; Cheong, Alexander; Steinbok, Paul
2018-03-12
In 2003, pediatric neurosurgeons were surveyed under the auspices of the education committee of the International Society for Pediatric Neurosurgery (ISPN) to determine prevailing opinions regarding the management of Chiari I malformation (C1M) with and without associated syringomyelia. In the ensuing years, there has been further information from multiple C1M studies, with regards to indications, success rates of different surgical interventions, and complications. The purpose of this study was to re-evaluate current opinions and practices in pediatric C1M. Pediatric neurosurgeons worldwide were surveyed, using an e-mail list provided by the ISPN communication committee chairperson. Respondents were given scenarios similar to the 2003 C1M survey in order to determine opinions regarding whether to surgically intervene, and if so, with which operations. Of 300 surveys electronically distributed, 122 responses were received (40.6% response rate)-an improvement over the 30.8% response rate in 2003. Pediatric neurosurgeons from 34 different countries responded. There was broad consensus that non-operative management is appropriate in asymptomatic C1M (> 90%) as well as asymptomatic C1M with a small syrinx (> 65%). With a large syrinx, a majority (almost 80%) recommended surgical intervention. Scoliotic patients with CIM were generally offered surgery only when there was a large syrinx. There has been a shift in the surgical management over the past decade, with a bone-only decompression now being offered more commonly. There remains, however, great variability in the operation offered. This survey, with a relatively strong response rate, and with broad geographic representation, summarizes current worldwide expert opinion regarding management of pediatric C1M. Asymptomatic C1M and C1M with a small syrinx are generally managed non-operatively. When an operation is indicated, there has been a shift towards less invasive surgical approaches.
Operator control systems and methods for swing-free gantry-style cranes
Feddema, J.T.; Petterson, B.J.; Robinett, R.D. III
1998-07-28
A system and method are disclosed for eliminating swing motions in gantry-style cranes while subject to operator control. The present invention comprises an infinite impulse response (IIR) filter and a proportional-integral (PI) feedback controller. The IIR filter receives input signals (commanded velocity or acceleration) from an operator input device and transforms them into output signals in such a fashion that the resulting motion is swing free (i.e., end-point swinging prevented). The parameters of the IIR filter are updated in real time using measurements from a hoist cable length encoder. The PI feedback controller compensates for modeling errors and external disturbances, such as wind or perturbations caused by collision with objects. The PI feedback controller operates on cable swing angle measurements provided by a cable angle sensor. The present invention adjusts acceleration and deceleration to eliminate oscillations. An especially important feature of the present invention is that it compensates for variable-length cable motions from multiple cables attached to a suspended payload. 10 figs.
Operator control systems and methods for swing-free gantry-style cranes
Feddema, John T.; Petterson, Ben J.; Robinett, III, Rush D.
1998-01-01
A system and method for eliminating swing motions in gantry-style cranes while subject to operator control is presented. The present invention comprises an infinite impulse response ("IIR") filter and a proportional-integral ("PI") feedback controller (50). The IIR filter receives input signals (46) (commanded velocity or acceleration) from an operator input device (45) and transforms them into output signals (47) in such a fashion that the resulting motion is swing free (i.e., end-point swinging prevented). The parameters of the IIR filter are updated in real time using measurements from a hoist cable length encoder (25). The PI feedback controller compensates for modeling errors and external disturbances, such as wind or perturbations caused by collision with objects. The PI feedback controller operates on cable swing angle measurements provided by a cable angle sensor (27). The present invention adjusts acceleration and deceleration to eliminate oscillations. An especially important feature of the present invention is that it compensates for variable-length cable motions from multiple cables attached to a suspended payload.
Reducing cost with autonomous operations of the Deep Space Network radio science receiver
NASA Technical Reports Server (NTRS)
Asmar, S.; Anabtawi, A.; Connally, M.; Jongeling, A.
2003-01-01
This paper describes the Radio Science Receiver system and the savings it has brought to mission operations. The design and implementation of remote and autonomous operations will be discussed along with the process of including user feedback along the way and lessons learned and procedures avoided.
The development of an advanced generic solar dynamic heat receiver thermal model
NASA Technical Reports Server (NTRS)
Wu, Y. C.; Roschke, E. J.; Kohout, L.
1988-01-01
An advanced generic solar dynamic heat receiver thermal model under development which can analyze both orbital transient and orbital average conditions is discussed. This model can be used to study advanced receiver concepts, evaluate receiver concepts under development, analyze receiver thermal characteristics under various operational conditions, and evaluate solar dynamic system thermal performances in various orbit conditions. The model and the basic considerations that led to its creation are described, and results based on a set of baseline orbit, configuration, and operational conditions are presented to demonstrate the working of the receiver model.
Micromachined Millimeter- and Submillimeter-wave SIS Heterodyne Receivers for Remote Sensing
NASA Technical Reports Server (NTRS)
Hu, Qing
1997-01-01
This is a progress report for the second year of a NASA-sponsored project. The report discusses the design and fabrication of micromachined Superconductor Insulator Superconductor (SIS) heterodyne receivers with integrated tuning elements. These receivers tune out the functional capacitance at desired frequencies, resulting in less noise, lower temperatures and broader bandwidths. The report also discusses the design and fabrication of the first monolithic 3x3 focal-plane arrays for a frequency range of 170-210 GHz. Also addressed is the construction of a 9-channel bias and read-out system, as well as the redesign of the IF connections to reduce cross talk between SIS junctions, which become significant a frequency of 1.5 GHz IF. Uniformity of the junction arrays were measured and antenna beam patterns of several array elements under operating conditions also were measured. Finally, video and heterodyne responses of our focal-plane arrays were measured as well. Attached is a paper on: 'Development of a 170-210 GHz 3x3 micromachined SIS imaging array'.
DeRobertis, Christopher V.; Lu, Yantian T.
2010-02-23
A method, system, and program storage device for creating a new user account or user group with a unique identification number in a computing environment having multiple user registries is provided. In response to receiving a command to create a new user account or user group, an operating system of a clustered computing environment automatically checks multiple registries configured for the operating system to determine whether a candidate identification number for the new user account or user group has been assigned already to one or more existing user accounts or groups, respectively. The operating system automatically assigns the candidate identification number to the new user account or user group created in a target user registry if the checking indicates that the candidate identification number has not been assigned already to any of the existing user accounts or user groups, respectively.
Barret, Scott T; Bevins, Rick A
2013-12-01
Nicotine enhancement of reward has been implicated as an important contributor to tobacco addiction. Despite the attention that reward enhancement has received, the behavioral mechanisms whereby nicotine enhances operant responding remain largely unknown. The present study sought to extend previous work by evaluating the effects of nicotine on responding for two qualitatively different rewards (visual stimulation (VS) and 4% sucrose solution) under fixed-ratio (FR) maintenance and extinction conditions. Sprague–Dawley rats were trained to press an active lever for VS (Experiment 1) or 4% sucrose solution (Experiment 2) and evaluated over 15 sessions on a FR5 schedule of reinforcement. Nicotine (0.4 mg base/kg, SC) or saline were administered 5 min before each session; the alternate solution was given in the home cage after the session. The effects of nicotine on extinction responding were then assessed over 5 sessions and rats were divided into 4 groups based on drug of injection received during FR-maintenance and extinction phases (maintenance–extinction): Nic–Nic, Nic–Sal, Sal–Sal, and Sal–Nic. Nicotine increased active lever response rates for both VS and 4% sucrose under FR5 maintenance conditions. Nicotine also increased response rates in the Nic–Nic group relative to all other groups under extinction conditions in both experiments, though this effect had greater longevity following VS maintenance conditions than sucrose. Enhancement of responding during extinction does not appear dependent upon locomotor activation by nicotine.
Chen, Jan-Yow; Lin, Kuo-Hung; Chang, Kuan-Cheng; Chou, Che-Yi
2017-08-03
QRS duration has been associated with the response to cardiac resynchronization therapy (CRT). However, the methods for defining QRS duration to predict the outcome of CRT have discrepancies in previous reports. The aim of this study was to determine an optimal measurement of QRS duration to predict the response to CRT.Sixty-one patients who received CRT were analyzed. All patients had class III-IV heart failure, left ventricular ejection fraction not more than 35%, and complete left bundle branch block. The shortest, longest, and average QRS durations from the 12 leads of each electrocardiogram (ECG) were measured. The responses to CRT were determined using the changes in echocardiography after 6 months. Thirty-five (57.4%) patients were responders and 26 (42.6%) patients were non-responders. The pre-procedure shortest, average, and longest QRS durations and the QRS shortening (ΔQRS) of the shortest QRS duration were significantly associated with the response to CRT in a univariate logistic regression analysis (P = 0.002, P = 0.03, P = 0.04 and P = 0.04, respectively). Based on the measurement of the area under curve of the receiver operating characteristic curve, only the pre-procedure shortest QRS duration and the ΔQRS of the shortest QRS duration showed significant discrimination for the response to CRT (P = 0.002 and P = 0.038, respectively). Multivariable logistic regression showed the pre-procedure shortest QRS duration is an independent predictor for the response to CRT.The shortest QRS duration from the 12 leads of the electrocardiogram might be an optimal measurement to predict the response to CRT.
Bremner, James Douglas; Mishra, Sanskriti; Campanella, Carolina; Shah, Majid; Kasher, Nicole; Evans, Sarah; Fani, Negar; Shah, Amit Jasvant; Reiff, Collin; Davis, Lori L; Vaccarino, Viola; Carmody, James
2017-01-01
Brain imaging studies in patients with post-traumatic stress disorder (PTSD) have implicated a circuitry of brain regions including the medial prefrontal cortex, amygdala, hippocampus, parietal cortex, and insula. Pharmacological treatment studies have shown a reversal of medial prefrontal deficits in response to traumatic reminders. Mindfulness-based stress reduction (MBSR) is a promising non-pharmacologic approach to the treatment of anxiety and pain disorders. The purpose of this study was to assess the effects of MBSR on PTSD symptoms and brain response to traumatic reminders measured with positron-emission tomography (PET) in Operation Enduring Freedom/Operation Iraqi Freedom (OEF/OIF) combat veterans with PTSD. We hypothesized that MBSR would show increased prefrontal response to stress and improved PTSD symptoms in veterans with PTSD. Twenty-six OEF/OIF combat veterans with PTSD who had recently returned from a combat zone were block randomized to receive eight sessions of MBSR or present-centered group therapy (PCGT). PTSD patients underwent assessment of PTSD symptoms with the Clinician-Administered PTSD Scale (CAPS), mindfulness with the Five Factor Mindfulness Questionnaire (FFMQ) and brain imaging using PET in conjunction with exposure to neutral and Iraq combat-related slides and sound before and after treatment. Nine patients in the MBSR group and 8 in the PCGT group completed all study procedures. Post-traumatic stress disorder patients treated with MBSR (but not PCGT) had an improvement in PTSD symptoms measured with the CAPS that persisted for 6 months after treatment. MBSR also resulted in an increase in mindfulness measured with the FFMQ. MBSR-treated patients had increased anterior cingulate and inferior parietal lobule and decreased insula and precuneus function in response to traumatic reminders compared to the PCGT group. This study shows that MBSR is a safe and effective treatment for PTSD. Furthermore, MBSR treatment is associated with changes in brain regions that have been implicated in PTSD and are involved in extinction of fear responses to traumatic memories as well as regulation of the stress response.
NASA Astrophysics Data System (ADS)
Thomas, V. I.; Yu, E.; Acharya, P.; Jaramillo, J.; Chowdhury, F.
2015-12-01
Maintaining and archiving accurate site metadata is critical for seismic network operations. The Advanced National Seismic System (ANSS) Station Information System (SIS) is a repository of seismic network field equipment, equipment response, and other site information. Currently, there are 187 different sensor models and 114 data-logger models in SIS. SIS has a web-based user interface that allows network operators to enter information about seismic equipment and assign response parameters to it. It allows users to log entries for sites, equipment, and data streams. Users can also track when equipment is installed, updated, and/or removed from sites. When seismic equipment configurations change for a site, SIS computes the overall gain of a data channel by combining the response parameters of the underlying hardware components. Users can then distribute this metadata in standardized formats such as FDSN StationXML or dataless SEED. One powerful advantage of SIS is that existing data in the repository can be leveraged: e.g., new instruments can be assigned response parameters from the Incorporated Research Institutions for Seismology (IRIS) Nominal Response Library (NRL), or from a similar instrument already in the inventory, thereby reducing the amount of time needed to determine parameters when new equipment (or models) are introduced into a network. SIS is also useful for managing field equipment that does not produce seismic data (eg power systems, telemetry devices or GPS receivers) and gives the network operator a comprehensive view of site field work. SIS allows users to generate field logs to document activities and inventory at sites. Thus, operators can also use SIS reporting capabilities to improve planning and maintenance of the network. Queries such as how many sensors of a certain model are installed or what pieces of equipment have active problem reports are just a few examples of the type of information that is available to SIS users.
Preparing patients with cancer who work and treatment responsiveness.
Kamau, Caroline
2017-03-01
Many patients with life-limiting illnesses continue to work because of financial reasons and because work provides good psychosocial support. A lack of appropriate advice/support through patient education could, however, make having a job detrimental to well-being (eg, symptom worsening). This study investigated the frequency with which patients received information that empowers their understanding of their condition, treatment, side effects of treatment and the likely impact on occupational functioning. A cross-sectional study. An analysis of survey data from 3457 patients with cancer in employment. Logistic regression showed that patients who received information about the impact of cancer on work life or education are 1.72 times more likely to have a positive treatment outcome. Patients who receive written information about the type of cancer are 1.99 times more likely to have a positive treatment outcome. Also, patients who receive written information before a cancer-related operation are 1.90 times more likely to have a positive treatment outcome. Information about the side effects of cancer treatment produces worse odds of a positive treatment outcome (0.65-1). A stepwise logistic regression analysing the effects irrespective of current employment status in 6710 patients showed that preparing them produces nearly twice better odds of cancer treatment responsiveness. Palliative care teams should consider ways of actively advising patients who work. Whereas the results showed evidence of good practice in cancer care, there is a need to ensure that all working patients with potentially life-limiting illnesses receive similar support. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
25 CFR 47.3 - How does a Bureau-operated school find out how much funding it will receive?
Code of Federal Regulations, 2014 CFR
2014-04-01
... EDUCATION UNIFORM DIRECT FUNDING AND SUPPORT FOR BUREAU-OPERATED SCHOOLS § 47.3 How does a Bureau-operated school find out how much funding it will receive? The Office of Indian Education Programs (OIEP) will... 25 Indians 1 2014-04-01 2014-04-01 false How does a Bureau-operated school find out how much...
25 CFR 47.3 - How does a Bureau-operated school find out how much funding it will receive?
Code of Federal Regulations, 2011 CFR
2011-04-01
... EDUCATION UNIFORM DIRECT FUNDING AND SUPPORT FOR BUREAU-OPERATED SCHOOLS § 47.3 How does a Bureau-operated school find out how much funding it will receive? The Office of Indian Education Programs (OIEP) will... 25 Indians 1 2011-04-01 2011-04-01 false How does a Bureau-operated school find out how much...
25 CFR 47.3 - How does a Bureau-operated school find out how much funding it will receive?
Code of Federal Regulations, 2012 CFR
2012-04-01
... EDUCATION UNIFORM DIRECT FUNDING AND SUPPORT FOR BUREAU-OPERATED SCHOOLS § 47.3 How does a Bureau-operated school find out how much funding it will receive? The Office of Indian Education Programs (OIEP) will... 25 Indians 1 2012-04-01 2011-04-01 true How does a Bureau-operated school find out how much...
25 CFR 47.3 - How does a Bureau-operated school find out how much funding it will receive?
Code of Federal Regulations, 2013 CFR
2013-04-01
... EDUCATION UNIFORM DIRECT FUNDING AND SUPPORT FOR BUREAU-OPERATED SCHOOLS § 47.3 How does a Bureau-operated school find out how much funding it will receive? The Office of Indian Education Programs (OIEP) will... 25 Indians 1 2013-04-01 2013-04-01 false How does a Bureau-operated school find out how much...
25 CFR 47.3 - How does a Bureau-operated school find out how much funding it will receive?
Code of Federal Regulations, 2010 CFR
2010-04-01
... EDUCATION UNIFORM DIRECT FUNDING AND SUPPORT FOR BUREAU-OPERATED SCHOOLS § 47.3 How does a Bureau-operated school find out how much funding it will receive? The Office of Indian Education Programs (OIEP) will... 25 Indians 1 2010-04-01 2010-04-01 false How does a Bureau-operated school find out how much...
DeRuiter, Stacy L; Southall, Brandon L; Calambokidis, John; Zimmer, Walter M X; Sadykova, Dinara; Falcone, Erin A; Friedlaender, Ari S; Joseph, John E; Moretti, David; Schorr, Gregory S; Thomas, Len; Tyack, Peter L
2013-08-23
Most marine mammal- strandings coincident with naval sonar exercises have involved Cuvier's beaked whales (Ziphius cavirostris). We recorded animal movement and acoustic data on two tagged Ziphius and obtained the first direct measurements of behavioural responses of this species to mid-frequency active (MFA) sonar signals. Each recording included a 30-min playback (one 1.6-s simulated MFA sonar signal repeated every 25 s); one whale was also incidentally exposed to MFA sonar from distant naval exercises. Whales responded strongly to playbacks at low received levels (RLs; 89-127 dB re 1 µPa): after ceasing normal fluking and echolocation, they swam rapidly, silently away, extending both dive duration and subsequent non-foraging interval. Distant sonar exercises (78-106 dB re 1 µPa) did not elicit such responses, suggesting that context may moderate reactions. The observed responses to playback occurred at RLs well below current regulatory thresholds; equivalent responses to operational sonars could elevate stranding risk and reduce foraging efficiency.
Post-operative course of coronary artery bypass surgery patients who pre-donate autologous blood.
Jovin, Ion S; Stelzig, Georg; Strelitz, Joachim C; Taborski, Uwe; Jovin, Angelika; Heidinger, Kathrin; Klövekorn, Wolf-Peter; Müller-Berghaus, Gert
2003-12-01
Pre-operative autologous blood donation is used to reduce the need of allogeneic blood in patients undergoing coronary bypass surgery operations, but it is not clear what impact the blood donation has on the post-operative course of these patients. We studied the post-operative course of 210 patients who pre-donated autologous blood before their coronary bypass operation (donors) and of 67 patients who were eligible to pre-donate but did not (controls). The clinical variables and the technical operative parameters of the patients in the two groups were similar. There was no significant difference between the duration of assisted ventilation post-operatively (756 +/- 197 vs. 802 +/- 395 min; P=0.54) or length of stay in the intensive care unit (1.8 +/- 1.1 vs. 1.7 +/- 0.9 days; P=0.52) of the two groups. The number of autologous units of packed red cells and of fresh frozen plasma (FFP) received by the donors was significantly higher than the number of units of allogeneic packed red cells (1.5 +/- 0.9 vs. 0.3 +/- 0.9; P=0.001) and the units of homologous FFP received by the controls (2.3 +/- 0.8 vs. 0.6 +/- 1; P=0.001). We found no evidence that autologous blood donation exerted a negative influence on the post-operative course of patients undergoing coronary bypass surgery. Patients who pre-donated blood received no allogeneic blood products, but the number of autologous blood products received by donors was higher than the number of blood products received by patients who did not pre-donate.
Kramers-Kronig receiver operable without digital upsampling.
Bo, Tianwai; Kim, Hoon
2018-05-28
The Kramers-Kronig (KK) receiver is capable of retrieving the phase information of optical single-sideband (SSB) signal from the optical intensity when the optical signal satisfies the minimum phase condition. Thus, it is possible to direct-detect the optical SSB signal without suffering from the signal-signal beat interference and linear transmission impairments. However, due to the spectral broadening induced by nonlinear operations in the conventional KK algorithm, it is necessary to employ the digital upsampling at the beginning of the digital signal processing (DSP). The increased number of samples at the DSP would hinder the real-time implementation of this attractive receiver. Hence, we propose a new DSP algorithm for KK receiver operable at 2 samples per symbol. We adopt a couple of mathematical approximations to avoid the use of nonlinear operations such as logarithm and exponential functions. By using the proposed algorithm, we demonstrate the transmission of 112-Gb/s SSB orthogonal frequency-division-multiplexed signal over an 80-km fiber link. The results show that the proposed algorithm operating at 2 samples per symbol exhibits similar performance to the conventional KK one operating at 6 samples per symbol. We also present the error analysis of the proposed algorithm for KK receiver in comparison with the conventional one.
NASA Technical Reports Server (NTRS)
Parrish, E. A., Jr.; Aylor, J. H.
1975-01-01
To aid work being conducted on the feasibility of a low cost Omega navigational receiver, a control panel was designed and constructed according to supplied specifications. Since the proposed Omega receiver is designed around a microprocessor, software engineering necessary for control panel operation is included in the design. The control panel is to be used as an operational model for use in the design of a prototype receiver. A detailed description of the hardware design is presented along with a description of the software needed to operate the panel. A complete description of the operating procedures for the panel are also included.
Operational adaptability evaluation index system of pumped storage in UHV receiving-end grids
NASA Astrophysics Data System (ADS)
Yuan, Bo; Zong, Jin; Feng, Junshu
2017-01-01
Pumped storage is an effective solution to deal with the emergency reserve shortage, renewable energy accommodating and peak-shaving problems in ultra-high voltage (UHV) transmission receiving-end grids. However, governments and public opinion in China tend to evaluate the operational effectiveness of pumped storage using annual utilization hour, which may result in unreasonable and unnecessary dispatch of pumped storage. This paper built an operational adaptability evaluation index system for pumped storage in UHV-receiving end grids from three aspects: security insurance, peak-shaving and renewable energy accommodating, which can provide a comprehensive and objective way to evaluate the operational performance of a pumped storage station.
47 CFR 15.121 - Scanning receivers and frequency converters used with scanning receivers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... incapable of operating (tuning), or readily being altered by the user to operate, within the frequency bands...). Scanning receivers capable of “readily being altered by the user” include, but are not limited to, those... by this paragraph shall be placed in a prominent location in the instruction manual or pamphlet...
Theoretical Limits on Multiuser Molecular Communication in Internet of Nano-Bio Things.
Dinc, Ergin; Akan, Ozgur B
2017-06-01
In nano-bio networks, multiple transmitter-receiver pairs will operate in the same medium. Both inter-symbol interference and multi-user interference can cause saturation at the receiver side, and this effect may cause an outage. Thus, we propose a tractable framework to calculate the theoretical operating points for fully absorbing receiver.
Jani, Meghna; Chinoy, Hector; Warren, Richard B.; Griffiths, Christopher E. M.; Plant, Darren; Fu, Bo; Morgan, Ann W.; Wilson, Anthony G.; Isaacs, John D.; Hyrich, KimmeL.; Prouse, P. J.; Moitra, R. K.; Shawe, D. J.; Nisar, M.; Fairburn, K.; Nixon, J.; Barnes, T.; Hui, M.; Coady, D.; Wright, D.; Morley, C.; Raftery, G.; Bracewell, C.; Bridges, M.; Armstrong, D.; Chuck, A. J.; Hailwood, S.; Kumar, N.; Ashok, D.; Reece, R.; O'Reilly, S. C.; Ding, T.; Badcock, L. J.; Deighton, C. M.; Raj, N.; Regan, M. R.; Summers, G. D.; Williams, R. A.; Lambert, J. R.; Stevens, R.; Wilkinson, C.; Kelly, C. A.; Hamilton, J.; Heycock, C. R.; Saravanan, V.; Cope, A.; Garrood, T.; Ng, N.; Kirkham, B.; Green, M.; Gough, A.; Lawson, C.; Das, D.; Borbas, E.; Wazir, T.; Emery, P.; Bingham, S.; Bird, H. A.; Conaghan, P.G.; Pease, C. T.; Wakefield, R. J.; Buch, M.; Bruce, I.; Gorodkin, R.; Ho, P.; Parker, B.; Smith, W.; Jenkins, E.; Mukhtyar, C.; Gaffney, K.; Macgregor, A. J.; Marshall, T.; Merry, P.; DeSilva, C.; Birrell, F. N.; Crook, P. R.; Szebenyi, B.; Bates, D.; James, D.; Gillott, T.; Alvi, A.; Grey, C.; Browning, J.; McHale, J. F.; Gaywood, I.C.; Jones, A. C.; Lanyon, P.; Pande, I.; Doherty, M.; Gupta, A.; Courtney, P. A.; Srikanth, A.; Abhishek, A.; Das, L.; Pattrick, M.; Snowden, H. N.; Bowden, A. P.; Smith, E. E.; Klimiuk, P.; Speden, D. J.; Naz, S.; Ledingham, J. M.; Hull, R. G.; McCrae, F.; Cooper, A.; Young‐Min, S. A.; Wong, E.; Shaban, R.; Woolf, A. D.; Davis, M.; Hutchinson, D.; Endean, A.; Mewar, D.; Tunn, E. J.; Nelson, K.; Kennedy, T. D.; Dubois, C.; Pauling, J.; Korendowych, E.; Jenkinson, T.; Sengupta, R.; Bhalla, A.; McHugh, N.; O'Neil, T.; Herrick, A. L.; Jones, A. K.; Cooper, R. G.; Dixon, W. G.; Harrison, B.; Buckley, C. D.; Carruthers, D. C.; Elamanchi, R.; Gordon, P. C.; Grindulis, K. A.; Khattak, F.; Raza, K.; Situnayake, K.; Akil, M.; Till, S.; Dunkley, L.; Tattersall, R.; Kilding, R.; Tait, T.; Maxwell, J.; Till, S.; Kuet, K.-P.; Plant, M. J.; Clarke, F.; Fordham, J. N.; Tuck, S.; Pathare, S. K.; Paul, A.; Marguerie, C. P.; Rigby, S. P.; Dunn, N.; Abbas, I.; Filer, C.; Abernethy, V. E.; Clewes, A. R.; Dawson, J. K.; Kitas, G.; Erb, N.; Klocke, R.; Whallett, A. J.; Douglas, K.; Pace, A.; Sandhu, R.; John, H.; Shand, L.; Lane, S.; Foster, H.; Griffiths, B.; Griffiths, I.; Kay, L.; Ng, W.-F.; Platt, P. N.; Walker, D. J.; Peterson, P.; Lorenzi, A.; Friswell, M.; Thompson, B.; Lee, M.; Pratt, A.; Hopkinson, N. D.; Dunne, C. A.; Quilty, B.; Marks, J.; Mukherjee, S.; Mulherin, D.; Chalam, S. V.; Price, T.; Sheeran, T.; Venkatachalam, S.; Baskar, S.; Al- Allaf, W.; McKenna, F.; Shah, P.; Filer, A.; Bowman, S. J.; Jobanputra, P.; Rankin, E. C.; Allen, M.; Chaudhuri, K.; Dubey, S.; Price‐Forbes, A.; Ravindran, J.; Samanta, A.; Sheldon, P.; Hassan, W.; Francis, J.; Kinder, A.; Neame, R.; Moorthy, A.; Bukhari, M.; Ottewell, L.; Palkonyai, E.; Hider, S.; Hassell, A.; Menon, A.; Dowson, C.; Kamath, S.; Packham, J.; Dutta, S.; Price, S.; Roddy, E.; Paskins, Z.; O'Reilly, D. T.; Rajagopal, V.; Bhagat, S.; Chattopadhyay, C. B.; Green, M.; Quinn, D.; Isdale, A.; Brown, A.; Saleem, B.; Foo, B.; Al Saffar, Z.; Koduri, G.
2015-01-01
Objective To investigate whether antidrug antibodies and/or drug non‐trough levels predict the long‐term treatment response in a large cohort of patients with rheumatoid arthritis (RA) treated with adalimumab or etanercept and to identify factors influencing antidrug antibody and drug levels to optimize future treatment decisions. Methods A total of 331 patients from an observational prospective cohort were selected (160 patients treated with adalimumab and 171 treated with etanercept). Antidrug antibody levels were measured by radioimmunoassay, and drug levels were measured by enzyme‐linked immunosorbent assay in 835 serial serum samples obtained 3, 6, and 12 months after initiation of therapy. The association between antidrug antibodies and drug non‐trough levels and the treatment response (change in the Disease Activity Score in 28 joints) was evaluated. Results Among patients who completed 12 months of followup, antidrug antibodies were detected in 24.8% of those receiving adalimumab (31 of 125) and in none of those receiving etanercept. At 3 months, antidrug antibody formation and low adalimumab levels were significant predictors of no response according to the European League Against Rheumatism (EULAR) criteria at 12 months (area under the receiver operating characteristic curve 0.71 [95% confidence interval (95% CI) 0.57, 0.85]). Antidrug antibody–positive patients received lower median dosages of methotrexate compared with antidrug antibody–negative patients (15 mg/week versus 20 mg/week; P = 0.01) and had a longer disease duration (14.0 versus 7.7 years; P = 0.03). The adalimumab level was the best predictor of change in the DAS28 at 12 months, after adjustment for confounders (regression coefficient 0.060 [95% CI 0.015, 0.10], P = 0.009). Etanercept levels were associated with the EULAR response at 12 months (regression coefficient 0.088 [95% CI 0.019, 0.16], P = 0.012); however, this difference was not significant after adjustment. A body mass index of ≥30 kg/m2 and poor adherence were associated with lower drug levels. Conclusion Pharmacologic testing in anti–tumor necrosis factor–treated patients is clinically useful even in the absence of trough levels. At 3 months, antidrug antibodies and low adalimumab levels are significant predictors of no response according to the EULAR criteria at 12 months. PMID:26109489
Smith, J Joshua; Chow, Oliver S; Gollub, Marc J; Nash, Garrett M; Temple, Larissa K; Weiser, Martin R; Guillem, José G; Paty, Philip B; Avila, Karin; Garcia-Aguilar, Julio
2015-10-23
Treatment of patients with non-metastatic, locally advanced rectal cancer (LARC) includes pre-operative chemoradiation, total mesorectal excision (TME) and post-operative adjuvant chemotherapy. This trimodality treatment provides local tumor control in most patients; but almost one-third ultimately die from distant metastasis. Most survivors experience significant impairment in quality of life (QoL), due primarily to removal of the rectum. A current challenge lies in identifying patients who could safely undergo rectal preservation without sacrificing survival benefit and QoL. This multi-institutional, phase II study investigates the efficacy of total neoadjuvant therapy (TNT) and selective non-operative management (NOM) in LARC. Patients with MRI-staged Stage II or III rectal cancer amenable to TME will be randomized to receive FOLFOX/CAPEOX: a) before induction neoadjuvant chemotherapy (INCT); or b) after consolidation neoadjuvant chemotherapy (CNCT), with 5-FU or capecitabine-based chemoradiation. Patients in both arms will be re-staged after completing all neoadjuvant therapy. Those with residual tumor at the primary site will undergo TME. Patients with clinical complete response (cCR) will receive non-operative management (NOM). NOM patients will be followed every 3 months for 2 years, and every 6 months thereafter. TME patients will be followed according to NCCN guidelines. All will be followed for at least 5 years from the date of surgery or--in patients treated with NOM--the last day of treatment. The studies published thus far on the safety of NOM in LARC have compared survival between select groups of patients with a cCR after NOM, to patients with a pathologic complete response (pCR) after TME. The current study compares 3-year disease-free survival (DFS) in an entire population of patients with LARC, including those with cCR and those with pCR. We will compare the two arms of the study with respect to organ preservation at 3 years, treatment compliance, adverse events and surgical complications. We will measure QoL in both groups. We will analyze molecular indications that may lead to more individually tailored treatments in the future. This will be the first NOM trial utilizing a regression schema for response assessment in a prospective fashion. NCT02008656.
24 CFR 990.190 - Other formula expenses (add-ons).
Code of Federal Regulations, 2010 CFR
2010-04-01
... operating subsidy is determined to be zero based on the formula is still eligible to receive operating... formula expenses (add-ons). In addition to calculating operating subsidy based on the PEL and UEL, a PHA's... receive an amount for PILOT in accordance with section 6(d) of the 1937 Act, based on its cooperation...
24 CFR 990.190 - Other formula expenses (add-ons).
Code of Federal Regulations, 2011 CFR
2011-04-01
... operating subsidy is determined to be zero based on the formula is still eligible to receive operating... formula expenses (add-ons). In addition to calculating operating subsidy based on the PEL and UEL, a PHA's... receive an amount for PILOT in accordance with section 6(d) of the 1937 Act, based on its cooperation...
Crandall, David L [Idaho Falls, ID; Watson, Richard W [Blackfoot, ID
2008-03-04
A firearm frame which is adapted to be disposed in operative relationship as a component part of a firearm, the firearm having disposed in operative relationships each with one or more of the others, a barrel, a receiver, and at least one firing mechanism; wherein the barrel and receiver form operative parts of a movable assembly and the at least one firing mechanism is disposed in a substantially stationary operative relationship therewith; the firearm frame including at least one elongated support structure discrete from the barrel and receiver, the elongated support structure being adapted to directly support the movable assembly in an operative movable relationship therewith; whereby at least one of the barrel and receiver is in direct contact with and movable on the elongated support structure; and, a firing mechanism support structure connected to the at least one elongated support structure, the firing mechanism support structure being adapted to have the firing mechanism connected thereto; the firearm frame also directly supporting the movable assembly and the firing mechanism in corresponding movable and stationary operative relationships each with the other.
Christou, N V; Tellado-Rodriguez, J; Chartrand, L; Giannas, B; Kapadia, B; Meakins, J; Rode, H; Gordon, J
1989-01-01
We measured the delayed type hypersensitivity (DTH) skin test response, along with additional variables of host immunocompetence in 245 preoperative patients to determine which variables are associated with septic-related deaths following operation. Of the 14 deaths (5.7%), 12 were related to sepsis and in 2 sepsis was contributory. The DTH response (p less than 0.00001), age (p less than 0.0002), serum albumin (p less than 0.003), hemoglobin (p less than 0.02), and total hemolytic complement (p less than 0.03), were significantly different between those who died and those who lived. By logistic regression analysis, only the DTH skin test response (log likelihood = 41.7, improvement X2 = 6.24, p less than 0.012) and the serum albumin (log likelihood = 44.8, improvement X2 = 17.7, p less than 0.001) were significantly and independently associated with the deaths. The resultant probability of mortality calculation equation was tested in a separate validation group of 519 patients (mortality = 5%) and yielded a good predictive capability as assessed by (1) X2 = 0.08 between observed and expected deaths, NS; (2) Goodman-Kruskall G statistic = 0.673) Receiver-Operating-Characteristic (ROC) curve analysis with an area under the ROC curve, Az = 0.79 +/- 0.05. We conclude that a reduced immune response (DTH skin test anergy) plus a nutritional deficit and/or acute-phase response change are both associated with increased septic-related deaths in elective surgical patients. PMID:2472781
Renewal after the punishment of free operant behavior.
Bouton, Mark E; Schepers, Scott T
2015-01-01
Three experiments examined the role of context in punishment learning. In Experiment 1, rats were trained to lever press for food in Context A and then punished for responding in Context B (by presenting response-contingent footshock). Punishment led to complete suppression of the response. However, when responding was tested (in extinction) in Contexts A and B, a strong renewal of responding occurred in Context A. In Experiment 2, renewal also occurred when initial reinforcement occurred in Context A, punishment occurred in Context B, and testing occurred in a new context (Context C). In both experiments, behavioral suppression and renewal were not observed in groups that received noncontingent (yoked) footshocks in Context B. In Experiment 3, 2 responses (lever press and chain pull) were separately reinforced in Contexts A and B and then punished in the opposite context. Although the procedure equated the contexts on their association with reinforcement and punishment, renewal of each response was observed when it was tested in its nonpunished context. The contexts also influenced response choice. Overall, the results suggest that punishment is specific to the context in which it is learned, and establish that its context-specificity does not depend on a simple association between the context and shock. Like extinction, punishment may involve learning to inhibit a specific response in a specific context. Implications for theories of punishment and for understanding the cessation of problematic operant behavior (e.g., drug abuse) are discussed. PsycINFO Database Record (c) 2015 APA, all rights reserved.
Flight and ground tests of a GOES satellite time receiver for satellite communications applications
NASA Technical Reports Server (NTRS)
Swanson, R. L.; Nichols, S. A.
1981-01-01
A satellite time receiver was tested in various environmental conditions during the past year. The commercial receiver designed to work with the National Oceanic and Atmospheric Administration's (NOAA) Geostationary Operational Environmental Satellites (GOES). The test program included operation at low elevation during flight in a military cargo aircraft and long term comparison with laboratory standards. The GOES satellite time receiver offers an opportunity to provide easy wide area coverage synchronization at low cost.
Sideband characterization and atmospheric observations with various 340 GHz heterodyne receivers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Renker, Matthias, E-mail: renker@iap.unibe.ch; Murk, Axel; Rea, Simon P.
2014-08-15
This paper describes sideband response measurements and atmospheric observations with a double sideband and two Single Sideband (SSB) receiver prototypes developed for the multi-beam limb sounder instrument stratosphere-troposphere exchange and climate monitor radiometer. We first show an advanced Fourier-Transform Spectroscopy (FTS) method for sideband response and spurious signal characterization. We then present sideband response measurements of the different prototype receivers and we compare the results of the SSB receivers with sideband measurements by injecting a continuous wave signal into the upper and lower sidebands. The receivers were integrated into a total-power radiometer and atmospheric observations were carried out. The observedmore » spectra were compared to forward model spectra to conclude on the sideband characteristics of the different receivers. The two sideband characterization methods show a high degree of agreement for both SSB receivers with various local oscillator settings. The measured sideband response was used to correct the forward model simulations. This improves the agreement with the atmospheric observations and explains spectral features caused by an unbalanced sideband response. The FTS method also allows to quantify the influence of spurious harmonic responses of the receiver.« less
Effects of Oxytocin Administration on Receiving Help.
Human, Lauren J; Woolley, Joshua D; Mendes, Wendy Berry
2017-11-27
Receiving help can be a "mixed blessing." Despite the many psychosocial benefits it can carry, it sometimes has negative psychological consequences, such as loss in self-esteem or enhanced guilt. It is, therefore, important to understand the factors that modify responses to receiving help from others. We explored the role of the hormone oxytocin (OT) on affective and social responses to receiving help, given the putative role of OT in social bonding and attunement. To this end, we manipulated whether help was received from a same-sex interaction partner (confederate) versus a control condition, crossed with a double-blind administration of intranasal OT (vs. placebo), and examined subjective and observer-rated participant responses to help. We observed significant interactions between OT and the help manipulation. In the placebo condition, receiving help from the interaction partner compared with the control condition had negative consequences, such that participants reported greater negative affect and came to view themselves and their interaction partners more negatively after interacting together on several tasks. What is important, however, is that OT administration buffered against these negative subjective responses to receiving help. Further, outside observers rated participants who received OT administration as expressing greater happiness and gratitude in response to help, relative to those who received placebo. In sum, in the context of receiving help from a stranger, oxytocin administration fostered more positive affective and social responses. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Approaches to solar cell design for pulsed laser power receivers
NASA Technical Reports Server (NTRS)
Jain, Raj K.; Landis, Geoffrey A.
1993-01-01
Using a laser to beam power from Earth to a photovoltaic receiver in space could be a technology with applications to many space missions. Extremely high average-power lasers would be required in a wavelength range of 700-1000 nm. However, high-power lasers inherently operate in a pulsed format. Existing solar cells are not well designed to respond to pulsed incident power. To better understand cell response to pulsed illumination at high intensity, the PC-1D finite-element computer model was used to analyze the response of solar cells to continuous and pulsed laser illumination. Over 50 percent efficiency was calculated for both InP and GaAs cells under steady-state illumination near the optimum wavelength. The time-dependent response of a high-efficiency GaAs concentrator cell to a laser pulse was modeled, and the effect of laser intensity, wavelength, and bias point was studied. Three main effects decrease the efficiency of a solar cell under pulsed laser illumination: series resistance, L-C 'ringing' with the output circuit, and current limiting due to the output inductance. The problems can be solved either by changing the pulse shape or designing a solar cell to accept the pulsed input. Cell design possibilities discussed are a high-efficiency, light-trapping silicon cell, and a monolithic, low-inductance GaAs cell.
Simultaneous excitation system for efficient guided wave structural health monitoring
NASA Astrophysics Data System (ADS)
Hua, Jiadong; Michaels, Jennifer E.; Chen, Xin; Lin, Jing
2017-10-01
Many structural health monitoring systems utilize guided wave transducer arrays for defect detection and localization. Signals are usually acquired using the ;pitch-catch; method whereby each transducer is excited in turn and the response is received by the remaining transducers. When extensive signal averaging is performed, the data acquisition process can be quite time-consuming, especially for metallic components that require a low repetition rate to allow signals to die out. Such a long data acquisition time is particularly problematic if environmental and operational conditions are changing while data are being acquired. To reduce the total data acquisition time, proposed here is a methodology whereby multiple transmitters are simultaneously triggered, and each transmitter is driven with a unique excitation. The simultaneously transmitted waves are captured by one or more receivers, and their responses are processed by dispersion-compensated filtering to extract the response from each individual transmitter. The excitation sequences are constructed by concatenating a series of chirps whose start and stop frequencies are randomly selected from a specified range. The process is optimized using a Monte-Carlo approach to select sequences with impulse-like autocorrelations and relatively flat cross-correlations. The efficacy of the proposed methodology is evaluated by several metrics and is experimentally demonstrated with sparse array imaging of simulated damage.
Pandemics and health equity: lessons learned from the H1N1 response in Los Angeles County.
Plough, Alonzo; Bristow, Benjamin; Fielding, Jonathan; Caldwell, Stephanie; Khan, Sinan
2011-01-01
Pandemic preparedness and response (as with all public health actions) occur within a social, cultural, and historical context of preexisting health disparities and, in some populations, underlying mistrust in government. Almost 200,000 people received H1N1 vaccine at 109 free, public mass vaccination clinics operated by the Los Angeles County Department of Public Health between October 23, 2009, and December 8, 2009. Wide racial/ethnic disparities in vaccination rates were observed with African Americans having the lowest rate followed by whites. Demographic information, including race/ethnicity, was obtained for 163 087 of the Los Angeles County residents who received vaccine. This information was compared with estimates of the Los Angeles County population distribution by race/ethnicity. Rate ratios of vaccination were as follows: white, reference; African American, 0.5; Asian, 3.2; Hispanic, 1.5; Native American, 1.9; and Pacific Islander, 4.3. Significant political challenges and media coverage focused on equity in vaccination access specifically in the African American population. An important challenge was community-level informal messaging that ran counter to the "official" messages. Finally, we present a partnership strategy, developed in response to the challenges, to improve outreach and build trust and engagement with African Americans in Los Angeles County.
Al Oweidi, Abdelkarim S; Klasen, Joachim; Al-Mustafa, Mahmoud M; Abu-Halaweh, Sami A; Al-Zaben, Khaled R; Massad, Islam M; Qudaisat, Ibrahim Y
2010-06-01
Recent studies suggest that preemptive analgesia may be effective in reducing postoperative pain. One physiologic explanation may be interference with the endogenous opioid response. We investigated whether long-lasting preoperative preemptive analgesia may have an effect on the hormonal stress response after total hip replacement. 42 patients scheduled for elective hip replacement for coxarthrosis were randomized to receive, on the day before the operation, either 5 ml*h(-1) ropivacaine 0.2% (study group, n = 21) or 5 ml*h(-1) saline (control group, n = 21). Postoperative analgesia was achieved in both groups by patient-controlled epidural analgesia (PCEA) with ropivacaine 0.2%. The main outcome measure was the concentration of authentic beta-endorphin [1-31] in plasma up to 4 days after surgery. Additional parameters included concentrations of adrenocorticotrope hormone and cortisol. Both groups were comparable concerning preoperative parameters and pain scores. Epidural blocks were sufficient in all patients for operative analgesia. Preemptive analgesia was performed for 11-20 hours in both groups and led to significantly decreased pain scores before surgery. Preemptive analgesia with epidural ropivacaine did not lead to decreased concentrations of beta-endorphin [1-31] before the start of surgery or in the postoperative period. Furthermore, no differences could be detected in the time course of beta-endorphin and adrenocorticotrope hormone after surgery. However, cortisol concentrations differed significantly between groups before the operation, but showed a comparable rise after surgery. Differences in postoperative pain after preemptive analgesia do not seem to be due to an altered endogenous opioid response.
Transient simulation of molten salt central receiver
NASA Astrophysics Data System (ADS)
Doupis, Dimitri; Wang, Chuan; Carcorze-Soto, Jorge; Chen, Yen-Ming; Maggi, Andrea; Losito, Matteo; Clark, Michael
2016-05-01
Alstom is developing concentrated solar power (CSP) utilizing 60/40wt% NaNO3-KNO3 molten salt as the working fluid in a tower receiver for the global renewable energy market. In the CSP power generation cycle, receivers undergo a daily cyclic operation due to the transient nature of solar energy. Development of robust and efficient start-up and shut-down procedures is critical to avoiding component failures due to mechanical fatigue resulting from thermal transients, thus maintaining the performance and availability of the CSP plant. The Molten Salt Central Receiver (MSCR) is subject to thermal transients during normal daily operation, a cycle that includes warmup, filling, operation, draining, and shutdown. This paper describes a study to leverage dynamic simulation and finite element analysis (FEA) in development of start-up, shutdown, and transient operation concepts for the MSCR. The results of the FEA also verify the robustness of the MSCR design to the thermal transients anticipated during the operation of the plant.
Receiver-exciter controller design
NASA Technical Reports Server (NTRS)
Jansma, P. A.
1982-01-01
A description of the general design of both the block 3 and block 4 receiver-exciter controllers for the Deep Space Network (DSN) Mark IV-A System is presented along with the design approach. The controllers are designed to enable the receiver-exciter subsystem (RCV) to be configured, calibrated, initialized and operated from a central location via high level instructions. The RECs are designed to be operated under the control of the DMC subsystem. The instructions are in the form of standard subsystem blocks (SSBs) received via the local area network (LAN). The centralized control provided by RECs and other DSCC controllers in Mark IV-A is intended to reduce DSN operations costs from the Mark III era.
The correlation between ketamine and posttraumatic stress disorder in burned service members.
McGhee, Laura L; Maani, Christopher V; Garza, Thomas H; Gaylord, Kathryn M; Black, Ian H
2008-02-01
Predisposing factors for posttraumatic stress disorder (PTSD) include experiencing a traumatic event, threat of injury or death, and untreated pain. Ketamine, an anesthetic, is used at low doses as part of a multimodal anesthetic regimen. However, since ketamine is associated with psychosomatic effects, there is a concern that ketamine may increase the risk of developing PTSD. This study investigated the prevalence of PTSD in Operation Iraqi Freedom/Operation Enduring Freedom (OIF/OEF) service members who were treated for burns in a military treatment center. The PTSD Checklist-Military (PCL-M) is a 17-question screening tool for PTSD used by the military. A score of 44 or higher is a positive screen for PTSD. The charts of all OIF/OEF soldiers with burns who completed the PCL-M screening tool (2002-2007) were reviewed to determine the number of surgeries received, the anesthetic regime used, including amounts given, the total body surface area burned, and injury severity score. Morphine equivalent units were calculated using standard dosage conversion factors. The prevalence of PTSD in patients receiving ketamine during their operation(s) was compared with patients not receiving ketamine. Of the 25,000 soldiers injured in OIF/OEF, United States Army Institute of Surgical Research received 603 burned casualties, of which 241 completed the PCL-M. Of those, 147 soldiers underwent at least one operation. Among 119 patients who received ketamine during surgery and 28 who did not; the prevalence of PTSD was 27% (32 of 119) versus 46% (13 of 28), respectively (p = 0.044). Contrary to expectations, patients receiving perioperative ketamine had a lower prevalence of PTSD than soldiers receiving no ketamine during their surgeries despite having larger burns, higher injury severity score, undergoing more operations, and spending more time in the ICU.
Krieger, Kristian; Amlôt, Richard; Rogers, M Brooke
2014-11-01
This paper discusses the management of public responses to incidents involving chemical, biological, radiological and nuclear materials (CBRN). Given the extraordinary technical and operational challenges of a response to a CBRN release including, but not limited to, hazard detection and identification, casualty decontamination and multi-agency co-ordination, it is not surprising that public psychological and behavioural responses to such incidents have received limited attention by scholars and practitioners alike. As a result, a lack of understanding about the role of the public in effective emergency response constitutes a major gap in research and practice. This limitation must be addressed as a CBRN release has the potential to have wide-reaching psychological and behavioural impacts which, in turn, impact upon public morbidity and mortality rates. This paper addresses a number of key issues: why public responses matter; how responses have been conceptualised by practitioners; what factors have been identified as influencing public responses to a CBRN release and similar extreme events, and what further analysis is needed in order to generate a better understanding of public responses to inform the management of public responses to a CBRN release. Copyright © 2014 Elsevier Ltd. All rights reserved.
Quantum displacement receiver for M-ary phase-shift-keyed coherent states
DOE Office of Scientific and Technical Information (OSTI.GOV)
Izumi, Shuro; Takeoka, Masahiro; Fujiwara, Mikio
2014-12-04
We propose quantum receivers for 3- and 4-ary phase-shift-keyed (PSK) coherent state signals to overcome the standard quantum limit (SQL). Our receiver, consisting of a displacement operation and on-off detectors with or without feedforward, provides an error probability performance beyond the SQL. We show feedforward operations can tolerate the requirement for the detector specifications.
NASA Astrophysics Data System (ADS)
Vetrov, A.; Mejzr, I.
2010-12-01
While developing a new Helicopter Time Domain Electromagnetic system (P-THEM), Pico Envirotec Inc (PEI) has studied the effect of the transmitter assembly on the acquired data. The P-THEM system consists of a loop-transmitter assembly, powered by a motor generator, 3-axis coil receiver attached at the midpoint of a tow cable and an additional Z-axis (dB/dt) receiver installed on the rear section of the transmitter loop. The system is towed by a helicopter on a 230 foot long tow cable. The transmitter loop is designed to produce a peak magnetic moment of approximately 250,000 NIA with a base frequency of 30 Hz (adjustable to 25Hz) and a quarter length duty cycle (4 ms on-time). The secondary field acquired with a dB/dt receiver coil consists of a ground response and a system response: SF=Rg+Rsys, where SF - the secondary field, Rg - ground response, Rsys - system response. The system itself, especially the transmitter assembly, being a conductor in an induced magnetic field, creates a magnetic anomaly. The influence of the transmitter assembly anomaly on the received signal depends on the position of the receiver coil against the transmitter, the intensity of on-time pulse and transmitter electro-magnetic properties. At the same time, the ground response acquired with a receiver coil depends on the length and the moment of transmitter pulse, as well as the position and distance of the receiver coil from the ground. This can be for vertical field (Z) receiver coil described as RXz(t)=e(t)pz(t)Rgz(t)+d(t)k(t)j(t)TXz(t), where RXz(t) - receiver response, e(t) - elevation of the receiver over the ground, pz(t) - horizontal projection of the receiver coil, Rgz(t) - vertical component of ground response, d(t) - distance (elevation) between the receiver coil and the transmitter loop, k(t) - the position of the receiver in the transmitter field, j(t) - the transmitter assembly electromagnetic properties, TXz(t) -transmitter field (Primary field on-time, and transmitter assembly response off-time). Changes in the electromagnetic properties of the transmitter loop and mechanical vibrations of the transmitter and receiver are much lower frequency in comparison with the base frequency and can be omitted from consideration of a one cycle length period. The transmitter assembly response has to be subtracted from acquired off-time decay for a correct interpretation of ground response. The transmitter influence is very low when the receiving coil is placed far away. However, the transmitter influence is very important when the receiver is close to the transmitter assembly due to the transmitter anomaly decay which then becomes greater than the ground response. The transmitter assembly off-time response can be registered when the system is flown at a sufficiently high altitude and it is not affected by ground conductors. A number of experiments were conducted to determine the transmitter influence content in the acquired data. The secondary dB/dt receiver installed at different elevations over the transmitter loop in test flights It showed the influence change of the transmitter assembly on the acquired secondary field (OFF-time) dependent upon the distance between the transmitter assembly and the receiver loop.
Optical Vector Receiver Operating Near the Quantum Limit
NASA Astrophysics Data System (ADS)
Vilnrotter, V. A.; Lau, C.-W.
2005-05-01
An optical receiver concept for binary signals with performance approaching the quantum limit at low average-signal energies is developed and analyzed. A conditionally nulling receiver that reaches the quantum limit in the absence of background photons has been devised by Dolinar. However, this receiver requires ideal optical combining and complicated real-time shaping of the local field; hence, it tends to be difficult to implement at high data rates. A simpler nulling receiver that approaches the quantum limit without complex optical processing, suitable for high-rate operation, had been suggested earlier by Kennedy. Here we formulate a vector receiver concept that incorporates the Kennedy receiver with a physical beamsplitter, but it also utilizes the reflected signal component to improve signal detection. It is found that augmenting the Kennedy receiver with classical coherent detection at the auxiliary beamsplitter output, and optimally processing the vector observations, always improves on the performance of the Kennedy receiver alone, significantly so at low average-photon rates. This is precisely the region of operation where modern codes approach channel capacity. It is also shown that the addition of background radiation has little effect on the performance of the coherent receiver component, suggesting a viable approach for near-quantum-limited performance in high background environments.
NASA aviation safety reporting system
NASA Technical Reports Server (NTRS)
1977-01-01
During the third quarter of operation of the Aviation Safety Reporting System (ASRS), 1429 reports concerning aviation safety were received from pilots, air traffic controllers, and others in the national aviation system. Details of the administration and results of the program are discussed. The design and construction of the ASRS data base are briefly presented. Altitude deviations and potential aircraft conflicts associated with misunderstood clearances were studied and the results are discussed. Summary data regarding alert bulletins, examples of alert bulletins and responses to them, and a sample of deidentified ASRS reports are provided.
Toward Optimizing VEMP: Calculating VEMP Inhibition Depth With a Generic Template.
Noij, Kimberley S; van Tilburg, Mark J; Herrmann, Barbara S; Marciniak, Piotr; Rauch, Steven D; Guinan, John J
2018-04-05
Cervical vestibular evoked myogenic potentials (cVEMP) indirectly reveal the response of the saccule to acoustic stimuli through the inhibition of sternocleidomastoid muscle electromyographic response. VEMP inhibition depth (VEMPid) is a recently developed metric that estimates the percentage of saccular inhibition. VEMPid provides both normalization and better accuracy at low response levels than amplitude-normalized cVEMPs. Hopefully, VEMPid will aid in the clinical assessment of patients with vestibulopatholgy. To calculate VEMPid a template is needed. In the original method, a subject's own cVEMP was used as the template, but this method can be problematic in patients who do not have robust cVEMP responses. We hypothesize that a "generic" template, created by assembling cVEMPs from healthy subjects, can be used to compute VEMPid, which would facilitate the use of VEMPid in subjects with pathological conditions. A generic template was created by averaging cVEMP responses from 6 normal subjects. To compare VEMPid calculations using a generic versus a subject-specific template, cVEMPs were obtained in 40 healthy subjects using 500, 750, and 1000 Hz tonebursts at sound levels ranging from 98 to 123 dB peSPL. VEMPids were calculated both with the generic template and with the subject's own template. The ability of both templates to determine whether a cVEMP was present or not was compared with receiver operating characteristic curves. No significant differences were found between VEMPid calculations using a generic template versus using a subject-specific template for all frequencies and sound levels. Based on the receiver operating characteristic curves, the subject-specific and generic template did an equally good job at determining threshold. Within limits, the shape of the generic template did not affect these results. A generic template can be used instead of a subject-specific template to calculate VEMPid. Compared with cVEMP normalized by electromyographic amplitudes, VEMPid is advantageous because it averages zero when there is no sound stimulus and it allows the accumulating VEMPid value to be shown during data acquisition as a guide to deciding when enough data has been collected.
47 CFR 22.579 - Operation of mobile transmitters across U.S.-Canada border.
Code of Federal Regulations, 2010 CFR
2010-10-01
... authority of base stations licensed under this part may receive two-way service while in Canada from... Mobile Operation § 22.579 Operation of mobile transmitters across U.S.-Canada border. Mobile stations licensed by Canada may receive two-way service while in the United States from stations licensed under this...
Code of Federal Regulations, 2010 CFR
2010-04-01
... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false What entities are eligible to receive funds to operate centers and provide training and operational support services? 670.300 Section 670.300... OF THE WORKFORCE INVESTMENT ACT Funding and Selection of Service Providers § 670.300 What entities...
2002-10-31
association with the High-frequency Active Auroral Research Program ( HAARP ). In addition to a classic riometer and a GPS Total Electron Content (TEC...sensor previously operating at the HAARP site, NWRA also operates a set of Transit receivers for measurements of TEC and scintillation at VHF and UHF...supplementing the receiver at HAARP with a receiver north of the site and an additional receiver installed south of the HAARP site.
Code of Federal Regulations, 2014 CFR
2014-01-01
... quantification system; data management and maintenance system; and control, oversight, and validation system for...-supervised institution's advanced IRB systems, operational risk management processes, operational risk data...-length basis between the seller and the obligor (intercompany accounts receivable and receivables subject...
Scanning tunneling microscope assembly, reactor, and system
Tao, Feng; Salmeron, Miquel; Somorjai, Gabor A
2014-11-18
An embodiment of a scanning tunneling microscope (STM) reactor includes a pressure vessel, an STM assembly, and three spring coupling objects. The pressure vessel includes a sealable port, an interior, and an exterior. An embodiment of an STM system includes a vacuum chamber, an STM reactor, and three springs. The three springs couple the STM reactor to the vacuum chamber and are operable to suspend the scanning tunneling microscope reactor within the interior of the vacuum chamber during operation of the STM reactor. An embodiment of an STM assembly includes a coarse displacement arrangement, a piezoelectric fine displacement scanning tube coupled to the coarse displacement arrangement, and a receiver. The piezoelectric fine displacement scanning tube is coupled to the coarse displacement arrangement. The receiver is coupled to the piezoelectric scanning tube and is operable to receive a tip holder, and the tip holder is operable to receive a tip.
Narrow field electromagnetic sensor system and method
McEwan, Thomas E.
1996-01-01
A narrow field electromagnetic sensor system and method of sensing a characteristic of an object provide the capability to realize a characteristic of an object such as density, thickness, or presence, for any desired coordinate position on the object. One application is imaging. The sensor can also be used as an obstruction detector or an electronic trip wire with a narrow field without the disadvantages of impaired performance when exposed to dirt, snow, rain, or sunlight. The sensor employs a transmitter for transmitting a sequence of electromagnetic signals in response to a transmit timing signal, a receiver for sampling only the initial direct RF path of the electromagnetic signal while excluding all other electromagnetic signals in response to a receive timing signal, and a signal processor for processing the sampled direct RF path electromagnetic signal and providing an indication of the characteristic of an object. Usually, the electromagnetic signal is a short RF burst and the obstruction must provide a substantially complete eclipse of the direct RF path. By employing time-of-flight techniques, a timing circuit controls the receiver to sample only the initial direct RF path of the electromagnetic signal while not sampling indirect path electromagnetic signals. The sensor system also incorporates circuitry for ultra-wideband spread spectrum operation that reduces interference to and from other RF services while allowing co-location of multiple electronic sensors without the need for frequency assignments.
Narrow field electromagnetic sensor system and method
McEwan, T.E.
1996-11-19
A narrow field electromagnetic sensor system and method of sensing a characteristic of an object provide the capability to realize a characteristic of an object such as density, thickness, or presence, for any desired coordinate position on the object. One application is imaging. The sensor can also be used as an obstruction detector or an electronic trip wire with a narrow field without the disadvantages of impaired performance when exposed to dirt, snow, rain, or sunlight. The sensor employs a transmitter for transmitting a sequence of electromagnetic signals in response to a transmit timing signal, a receiver for sampling only the initial direct RF path of the electromagnetic signal while excluding all other electromagnetic signals in response to a receive timing signal, and a signal processor for processing the sampled direct RF path electromagnetic signal and providing an indication of the characteristic of an object. Usually, the electromagnetic signal is a short RF burst and the obstruction must provide a substantially complete eclipse of the direct RF path. By employing time-of-flight techniques, a timing circuit controls the receiver to sample only the initial direct RF path of the electromagnetic signal while not sampling indirect path electromagnetic signals. The sensor system also incorporates circuitry for ultra-wideband spread spectrum operation that reduces interference to and from other RF services while allowing co-location of multiple electronic sensors without the need for frequency assignments. 12 figs.
Surgical Burn Care by Médecins Sans Frontières-Operations Center Brussels: 2008 to 2014.
Stewart, Barclay T; Trelles, Miguel; Dominguez, Lynette; Wong, Evan; Fiozounam, Hervé Tribunal; Hassani, Ghulam Hiadar; Akemani, Clemence; Naseer, Aemer; Ntawukiruwabo, Innocent Bagura; Kushner, Adam L
Humanitarian organizations care for burns during crisis and while supporting healthcare facilities in low-income and middle-income countries. This study aimed to define the epidemiology of burn-related procedures to aid humanitarian response. In addition, operational data collected from humanitarian organizations are useful for describing surgical need otherwise unmet by national health systems. Procedures performed in operating theatres run by Médecins Sans Frontières-Operations Centre Brussels (MSF-OCB) from July 2008 through June 2014 were reviewed. Surgical specialist missions were excluded. Burn procedures were quantified, related to demographics and reason for humanitarian response, and described. A total of 96,239 operations were performed at 27 MSF-OCB projects in 15 countries between 2008 and 2014. Of the 33,947 general surgical operations, 4,280 (11%) were for burns. This proportion steadily increased from 3% in 2008 to 24% in 2014. People receiving surgical care from conflict relief missions had nearly twice the odds of having a burn operation compared with people requiring surgery in communities affected by natural disaster (adjusted odds ratio, 1.94; 95% confidence interval, 1.46-2.58). Nearly 70% of burn procedures were planned serial visits to the theatre. A diverse skill set was required. Unmet humanitarian assistance needs increased US$400 million dollars in 2013 in the face of an increasing number of individuals affected by crisis and a growing surgical burden. Given the high volume of burn procedures performed at MSF-OCB projects and the resource intensive nature of burn management, requisite planning and reliable funding are necessary to ensure quality for burn care in humanitarian settings.
Safety of remifentanil in transsphenoidal surgery: A single-center analysis of 540 patients.
Cote, David J; Burke, William T; Castlen, Joseph P; King, Chih H; Zaidi, Hasan A; Smith, Timothy R; Laws, Edward R; Aglio, Linda S
2017-04-01
Although some studies have examined the efficacy and safety of remifentanil in patients undergoing neurosurgical procedures, none has examined its safety in transsphenoidal operations specifically. In this study, all transsphenoidal operations performed by a single author from 2008 to 2015 were retrospectively reviewed to evaluate the safety of remifentanil in a consecutive series of patients. During the study period, 540 transsphenoidal operations were identified. Of these, 443 (82.0%) patients received remifentanil intra-operatively; 97 (18.0%) did not. The two groups were well-matched with regard to demographic categories, comorbidities, and pre-operative medications (p>0.05), except pre-operative tobacco use (p=0.021). Patients were also well-matched with regard to radiographic features and surgical techniques. Patients who received remifentanil were more likely to harbor a macroadenoma (78.1% vs. 67.0%, p=0.025), and had slightly longer anesthesia time on average (269.2minvs. 239.4min, p=0.024). All pathologic diagnoses were well-matched between the two groups, except that patients receiving remifentanil were more likely to harbor a non-functioning adenoma (46.5% vs. 26.8%, p<0.001). Analysis of post-operative complications showed no significant difference between patients who received remifentanil and those who did not, and length of stay and prevalence of ICU stay did not differ between the two groups. In a well-matched series of 540 patients undergoing transsphenoidal surgery, remifentanil was found to be a safe anesthetic adjunct. There were no significant differences in post-operative hospital course or complications in patients who did and did not receive intra-operative remifentanil. Copyright © 2016 Elsevier Ltd. All rights reserved.
Application of nomographs for analysis and prediction of receiver spurious response EMI
NASA Astrophysics Data System (ADS)
Heather, F. W.
1985-07-01
Spurious response EMI for the front end of a superheterodyne receiver follows a simple mathematic formula; however, the application of the formula to predict test frequencies produces more data than can be evaluated. An analysis technique has been developed to graphically depict all receiver spurious responses usig a nomograph and to permit selection of optimum test frequencies. The discussion includes the math model used to simulate a superheterodyne receiver, the implementation of the model in the computer program, the approach to test frequency selection, interpretation of the nomographs, analysis and prediction of receiver spurious response EMI from the nomographs, and application of the nomographs. In addition, figures are provided of sample applications. This EMI analysis and prediction technique greatly improves the Electromagnetic Compatibility (EMC) test engineer's ability to visualize the scope of receiver spurious response EMI testing and optimize test frequency selection.
[Is female sterilization voluntary in El Salvador]?].
Bertrand, J T; Landry, E G; Araya Zelaya, J D
1986-01-01
Sexual sterilization has become an increasingly important family planning method in developing countries, and notably so in Latin America, but some controversy has surrounded the practice because of the suggestion that individuals are coerced into undergoing sterilization. With the goal of examining allegations that low-income women in El Salvador are sterilized without their full knowledge or consent in family planning programs financed by the US, researchers interviewed 648 women who had received the operation in one of 7 facilities in El Salvador. In general, women were interviewed 1 month after their operation, by 6 trained female interviewers, with the assurance that the follow-up effort was not in any way connected with the facility performing the operation. An effort to sample approximately the same number of women from each facility was not entirely successful because of access difficulties. Most interviewees had been sterilized at below 30 years of age (average age at sterilization was 28 years), had begun having children in adolescence, and had not received more than a primary education. They had an average of 3.4 children and 1/3 had experienced the death of at least 1 child. The response to the survey indicated that female sterilization in El Salvador is voluntary. Women were shown to be aware of other contraception options. They had found out about sterilization and had become further informed about the method through providers and through communications with other women who had known about the operation at least 3 years before making a decision to submit to it, and many had waited between 1 month and 1 year before/between the decision and the actual operation. Only 1 women claimed to have felt pressured to be sterilized, identifying her mother as the source of the pressure.
Koul, Abhinav; Ferraris, Victor; Davenport, Daniel L; Ramaiah, Chandrashekhar
2012-01-01
Antifibrinolytic agents such as aprotinin and epsilon aminocaproic acid limit postoperative bleeding and blood transfusion in patients undergoing cardiac operations using cardiopulmonary bypass (CPB). Recent evidence suggests that these agents have adverse side effects that influence operative mortality and morbidity. We studied postoperative bleeding, transfusion rates, and operative outcomes in our patients in order to assess the efficacy of these agents during cardiac operations requiring CPB. We reviewed records of 520 patients undergoing a variety of cardiac operations between January 2005 and May 2009. We measured multiple variables including pre-operative risk factors, antifibrinolytic agent used, and outcomes of operation, such as measures of bleeding and blood transfusion, as well as serious operative morbidity and mortality. Postoperative bleeding rates varied significantly between patients receiving aprotinin and those receiving aminocaproic acid (P < 0.05). There was an associated 12% decrease in operative site bleeding in aprotinin-treated patients compared with aminocaproic acid. There was no significant difference in the transfusion rates of packed red blood cells between patients receiving aminocaproic acid or aprotinin (P > 0.05), though individuals in the aprotinin group did receive FFP more frequently than patients in the aminocaproic acid group (P < 0.05). There was no significant difference in morbidity and mortality rates between patients in either drug group (P > 0.05). Our study shows that aprotinin is more effective at controlling operative site bleeding than aminocaproic acid. Reduced operative site bleeding did not portend better outcome or differences in transfusion requirements. Aminocaproic acid remains a safe and cost-effective option for antifibrinolytic prophylaxis because of unavailability of aprotinin. PMID:23101999
Forwardly movable assembly for a firearm
Crandall, David L [Idaho Falls, ID; Watson, Richard W [Blackfoot, ID
2007-06-05
A forwardly movable assembly for a firearm, the forwardly movable assembly adapted to be disposed in operative relationship relative to the other operative parts of a firearm, the firearm having in operative relationship each with one or more of the others: a barrel, a receiver, and at least one firing mechanism; the forwardly movable assembly comprising: the barrel and the receiver operatively connected with each other; a movable hand support structure to which at least one of the barrel and the receiver is connected, the barrel being movable therewith, the movable hand support structure being adapted to be gripped by an operator of the firearm; the forwardly movable assembly being adapted to be moved forward by an operator upon gripping the movable hand support structure and manually maneuvering the hand support structure forwardly; and, as the forwardly movable assembly is moved forwardly, the firing mechanism is completely disengaged therefrom and held substantially stationary relative thereto.
Administrative Services Staff with New Teleticketing Machine
1968-02-21
Peggy Heintz, left, receives an airline ticket from supervisor Judy Kuebeler in the Administrative Services Building at the National Aeronautics and Space Administration (NASA) Lewis Research Center. The center had recently purchased a teleticket machine that automatically printed airline tickets as directed by the airline’s computer system. The Administrative Services Branch had 55 staff members performing a variety of roles. They served as telephone operators and set up communications with other centers. They operated the motor pool, handled all travel arrangements, prepared forms and work instructions, and planned offices. The staff was also responsible for records management and storage. It was reported that the staff processed 65 bags of incoming mail per day, which was said to be on par with a city of 15,000 to 20,000 people.
NASA Technical Reports Server (NTRS)
Lee, Sukhan (Inventor)
1990-01-01
An artificial dexterous hand is provided for conformally engaging and manipulating objects. The hand includes an articulated digit which is connected to an engagement sub-assembly and has a first shape adaption mechanism associated with it. The digit has a digit base and first and second phalanges. The digit base is operatively interconnected to the first phalange by a base joint having a base pulley. The phalanges are operatively interconnected by a separate first phalange joint having a first phalange pulley. The engagement sub-assembly includes a tendon, which is received by the base pulley and by the first phalange pulley, and an actuation device for selectively tensioning the tendon. The first shape adaption mechanism is responsive to and receives the tendon. It is also situated between the base joint and the first phalange joint and is connected to the first phalange. Upon actuation by the actuation device, the phalanges are caused to pivot relative to the base joint and the second phalange is caused to pivot relative to the first phalange. At the same time, the first shape adaption mechanism controls the sequence of the aforementioned pivoting of the phalanges through application of braking force to the tendon.
Performance of RVGui sensor and Kodak Ektaspeed Plus film for proximal caries detection.
Abreu, M; Mol, A; Ludlow, J B
2001-03-01
A high-resolution charge-coupled device was used to compare the diagnostic performances obtained with Trophy's new RVGui sensor and Kodak Ektaspeed Plus film with respect to caries detection. Three acquisition modes of the Trophy RVGui sensor were compared with Kodak Ektaspeed Plus film. Images of the proximal surfaces of 40 extracted posterior teeth were evaluated by 6 observers. The presence or absence of caries was scored by means of a 5-point confidence scale. The actual caries status of each surface was determined through ground-section histology. Responses were evaluated by means of receiver operating characteristic analysis. Areas under receiver operating characteristic curves (A(Z)) were assessed through analysis of variance. The mean A(Z) scores were 0.85 for film, 0.84 for the high-resolution caries mode, and 0.82 for both the low resolution caries mode and the high-resolution periodontal mode. These differences were not statistically significant (P =.70). The differences among observers also were not statistically significant (P =.23). The performance of the RVGui sensor in high- and low-resolution modes for proximal caries detection is comparable to that of Ektaspeed Plus film.
Pulse homodyne field disturbance sensor
McEwan, Thomas E.
1997-01-01
A field disturbance sensor operates with relatively low power, provides an adjustable operating range, is not hypersensitive at close range, allows co-location of multiple sensors, and is inexpensive to manufacture. The sensor includes a transmitter that transmits a sequence of transmitted bursts of electromagnetic energy. The transmitter frequency is modulated at an intermediate frequency. The sequence of bursts has a burst repetition rate, and each burst has a burst width and comprises a number of cycles at a transmitter frequency. The sensor includes a receiver which receives electromagnetic energy at the transmitter frequency, and includes a mixer which mixes a transmitted burst with reflections of the same transmitted burst to produce an intermediate frequency signal. Circuitry, responsive to the intermediate frequency signal indicates disturbances in the sensor field. Because the mixer mixes the transmitted burst with reflections of the transmitted burst, the burst width defines the sensor range. The burst repetition rate is randomly or pseudo-randomly modulated so that bursts in the sequence of bursts have a phase which varies. A second range-defining mode transmits two radio frequency bursts, where the time spacing between the bursts defines the maximum range divided by two.
Pulse homodyne field disturbance sensor
McEwan, T.E.
1997-10-28
A field disturbance sensor operates with relatively low power, provides an adjustable operating range, is not hypersensitive at close range, allows co-location of multiple sensors, and is inexpensive to manufacture. The sensor includes a transmitter that transmits a sequence of transmitted bursts of electromagnetic energy. The transmitter frequency is modulated at an intermediate frequency. The sequence of bursts has a burst repetition rate, and each burst has a burst width and comprises a number of cycles at a transmitter frequency. The sensor includes a receiver which receives electromagnetic energy at the transmitter frequency, and includes a mixer which mixes a transmitted burst with reflections of the same transmitted burst to produce an intermediate frequency signal. Circuitry, responsive to the intermediate frequency signal indicates disturbances in the sensor field. Because the mixer mixes the transmitted burst with reflections of the transmitted burst, the burst width defines the sensor range. The burst repetition rate is randomly or pseudo-randomly modulated so that bursts in the sequence of bursts have a phase which varies. A second range-defining mode transmits two radio frequency bursts, where the time spacing between the bursts defines the maximum range divided by two. 12 figs.
A Low Power 2.4 GHz CMOS Mixer Using Forward Body Bias Technique for Wireless Sensor Network
NASA Astrophysics Data System (ADS)
Yin, C. J.; Murad, S. A. Z.; Harun, A.; Ramli, M. M.; Zulkifli, T. Z. A.; Karim, J.
2018-03-01
Wireless sensor network (WSN) is a highly-demanded application since the evolution of wireless generation which is often used in recent communication technology. A radio frequency (RF) transceiver in WSN should have a low power consumption to support long operating times of mobile devices. A down-conversion mixer is responsible for frequency translation in a receiver. By operating a down-conversion mixer at a low supply voltage, the power consumed by WSN receiver can be greatly reduced. This paper presents a development of low power CMOS mixer using forward body bias technique for wireless sensor network. The proposed mixer is implemented using CMOS 0.13 μm Silterra technology. The forward body bias technique is adopted to obtain low power consumption. The simulation results indicate that a low power consumption of 0.91 mW is achieved at 1.6 V supply voltage. Moreover, the conversion gain (CG) of 21.83 dB, the noise figure (NF) of 16.51 dB and the input-referred third-order intercept point (IIP3) of 8.0 dB at 2.4 GHz are obtained. The proposed mixer is suitable for wireless sensor network.
2010-03-26
important events receive the most attention. Ensures that absentees and flank units receive changes to the operation order. Transmits changes to them...York: Vintage Books, 1991. Fuller, J. F. C. Generalship: Its Diseases and Their Cure . Harrisburg, PA: Military Service Publishing Co., 1936
Code of Federal Regulations, 2014 CFR
2014-01-01
... management and maintenance system; and control, oversight, and validation system for credit risk of wholesale... advanced IRB systems, operational risk management processes, operational risk data and assessment systems... the seller and the obligor (intercompany accounts receivable and receivables subject to contra...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kutscher, C.; Burkholder, F.; Stynes, J. K.
2012-02-01
The thermal efficiency of a parabolic trough collector is a function of both the fraction of direct normal radiation absorbed by the receiver (the optical efficiency) and the heat lost to the environment when the receiver is at operating temperature. The thermal efficiency can be determined by testing the collector under actual operating conditions or by separately measuring these two components. This paper describes how outdoor measurement of the optical efficiency is combined with laboratory measurements of receiver heat loss to obtain the thermal efficiency curve. This paper describes this approach and also makes the case that there are advantagesmore » to plotting collector efficiency versus the difference between the operating temperature and the ambient temperature at which the receiver heat loss was measured divided by radiation to a fractional power (on the order of 1/3 but obtained via data regression) - as opposed to the difference between operating and ambient temperatures divided by the radiation. The results are shown to be robust over wide ranges of ambient temperature, sky temperature, and wind speed.« less
Methods for Processing and Interpretation of AIS Signals Corrupted by Noise and Packet Collisions
NASA Astrophysics Data System (ADS)
Poļevskis, J.; Krastiņš, M.; Korāts, G.; Skorodumovs, A.; Trokšs, J.
2012-01-01
The authors deal with the operation of Automatic Identification System (AIS) used in the marine traffic monitoring to broadcast messages containing information about the vessel: id, payload, size, speed, destination etc., meant primarily for avoidance of ship collisions. To extend the radius of AIS operation, it is envisaged to dispose its receivers on satellites. However, in space, due to a large coverage area, interfering factors are especially pronounced - such as packet collision, Doppler's shift and noise impact on AIS message receiving, pre-processing and decoding. To assess the quality of an AIS receiver's operation, a test was carried out in which, varying automatically frequency, amplitude, noise, and other parameters, the data on the ability of the receiver's ability to decode AIS signals are collected. In the work, both hardware- and software-based AIS decoders were tested. As a result, quite satisfactory statistics has been gathered - both on the common and the differing features of such decoders when operating in space. To obtain reliable data on the software-defined radio AIS receivers, further research is envisaged.
Simulator of human visual perception
NASA Astrophysics Data System (ADS)
Bezzubik, Vitalii V.; Belashenkov, Nickolai R.
2016-04-01
Difference of Circs (DoC) model allowing to simulate the response of neurons - ganglion cells as a reaction to stimuli is represented and studied in relation with representation of receptive fields of human retina. According to this model the response of neurons is reduced to execution of simple arithmetic operations and the results of these calculations well correlate with experimental data in wide range of stimuli parameters. The simplicity of the model and reliability of reproducing of responses allow to propose the conception of a device which can simulate the signals generated by ganglion cells as a reaction to presented stimuli. The signals produced according to DoC model are considered as a result of primary processing of information received from receptors independently of their type and may be sent to higher levels of nervous system of living creatures for subsequent processing. Such device may be used as a prosthesis for disabled organ.
Thermal resistance model for CSP central receivers
NASA Astrophysics Data System (ADS)
de Meyer, O. A. J.; Dinter, F.; Govender, S.
2016-05-01
The receiver design and heliostat field aiming strategy play a vital role in the heat transfer efficiency of the receiver. In molten salt external receivers, the common operating temperature of the heat transfer fluid or molten salt ranges between 285°C to 565°C. The optimum output temperature of 565°C is achieved by adjusting the mass flow rate of the molten salt through the receiver. The reflected solar radiation onto the receiver contributes to the temperature rise in the molten salt by means of heat transfer. By investigating published work on molten salt external receiver operating temperatures, corresponding receiver tube surface temperatures and heat losses, a model has been developed to obtain a detailed thermographic representation of the receiver. The steady state model uses a receiver flux map as input to determine: i) heat transfer fluid mass flow rate through the receiver to obtain the desired molten salt output temperature of 565°C, ii) receiver surface temperatures iii) receiver tube temperatures iv) receiver efficiency v) pressure drop across the receiver and vi) corresponding tube strain per panel.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 20 Employees' Benefits 4 2014-04-01 2014-04-01 false What entities are eligible to receive funds to operate centers and provide training and operational support services? 670.300 Section 670.300... UNDER TITLE I OF THE WORKFORCE INVESTMENT ACT Funding and Selection of Service Providers § 670.300 What...
Improvement of Hungarian Joint Terminal Attack Program
2013-06-13
LST Laser Spot Tracker NVG Night Vision Goggle ROMAD Radio Operator Maintainer and Driver ROVER Remotely Operated Video Enhanced Receiver TACP...visual target designation. The other component consists of a laser spot tracker (LST), which identifies targets by tracking laser energy reflecting...capability for every type of night time missions, laser spot tracker for laser spot search missions, remotely operated video enhanced receiver
Wireless system for explosion detection in underground structures
NASA Astrophysics Data System (ADS)
Chikhradze, M.; Bochorishvili, N.; Akhvlediani, I.; Kukhalashvili, D.; Kalichava, I.; Mataradze, E.
2009-06-01
Considering the growing threat of terrorist or accidental explosions in underground stations, underground highway and railway sections improvement of system for protecting people from explosions appears urgent. Current automatic protective devices with blast identification module and blast damping absorbers of various designs as their basic elements cannot be considered effective. Analysis revealed that low reliability of blast detection and delayed generation of start signal for the activation of an absorber are the major disadvantages of protective devices. Besides the transmission of trigger signal to an energy absorber through cable communication reduces the reliability of the operation of protective device due to a possible damage of electric wiring under blast or mechanical attack. This paper presents the outcomes of the studies conducted to select accurate criteria for blast identification and to design wireless system of activation of defensive device. The results of testing of blast detection methods (seismic, EMP, optical, on overpressure) showed that the proposed method, which implies constant monitoring of overpressure in terms of its reliability and response speed, best meets the requirements. Proposed wireless system for explosions identification and activation of protective device consists of transmitter and receiver modules. Transmitter module contains sensor and microprocessor equipped with blast identification software. Receiver module produces activation signal for operation of absorber. Tests were performed in the underground experimental base of Mining Institute. The time between the moment of receiving signal by the sensor and activation of absorber - 640 microsecond; distance between transmitter and receiver in direct tunnel - at least 150m; in tunnel with 900 bending - 50m. This research is sponsored by NATO's Public Diplomacy Division in the framework of "Science for Peace".
A Descriptive Analysis of US Prehospital Care Response to Law Enforcement Tactical Incidents.
Aberle, Sara J; Lohse, Christine M; Sztajnkrycer, Matthew D
2015-01-01
Law enforcement tactical incidents involve high-risk operations that exceed the capabilities of regular, uniformed police. Despite the existence of tactical teams for 50 years, little is known about the frequency or nature of emergency medical services (EMS) response to tactical events in the United States. The purpose of this study was to perform a descriptive analysis of tactical events reported to a national EMS database. Descriptive analysis of the 2012 National Emergency Medical Services Information System (NEMSIS) Public Release research data set, containing EMS emergency response data from 41 states. A total of 17,479,328 EMS events were reported, of which 3,953 events were coded as "Activation-Tactical or SWAT Specialty Service/Response Team." The most common level of prehospital care present on scene was basic life support (55.2%). The majority (72.3%) of tactical incident activations involved a single patient; mass casualty incidents occurred in 0.5% of events. The most common EMS response locations were homes (48.4%), streets or highways (37.0%), and public buildings (6.3%). The mean age of treated patients was 44.1 years ± 22.0 years; 3.5% of tactical incident activation patients were aged 8 years or less. Injuries were coded as firearm assault in 14.8% and as chemical exposure in 8.9% of events. Cardiac arrest occurred in 5.1% of patients, with the majority (92.2%) occurring prior to EMS arrival. The primary symptoms reported by EMS personnel were pain (37.4%), change in responsiveness (13.1%), and bleeding (8.1%). Advanced airway procedures occurred in 30 patients. No patients were documented as receiving tourniquets or needle thoracostomy. Approximately 11 EMS responses in support of law enforcement tactical operations occur daily in the United States. The majority occur in homes and involve a single patient. Advanced airway procedures are required in a minority of patients. Cardiac arrest is rare and occurs prior to EMS response in the majority of cases. Better understanding of the nature and location of EMS responses to tactical incidents is required to develop consistent EMS policies in support of law enforcement tactical operations. 2015.
47 CFR 97.121 - Restricted operation.
Code of Federal Regulations, 2013 CFR
2013-10-01
... station causes general interference to the reception of transmissions from stations operating in the domestic broadcast service when receivers of good engineering design, including adequate selectivity characteristics, are used to receive such transmissions, and this fact is made known to the amateur station...
47 CFR 97.121 - Restricted operation.
Code of Federal Regulations, 2012 CFR
2012-10-01
... station causes general interference to the reception of transmissions from stations operating in the domestic broadcast service when receivers of good engineering design, including adequate selectivity characteristics, are used to receive such transmissions, and this fact is made known to the amateur station...
47 CFR 97.121 - Restricted operation.
Code of Federal Regulations, 2014 CFR
2014-10-01
... station causes general interference to the reception of transmissions from stations operating in the domestic broadcast service when receivers of good engineering design, including adequate selectivity characteristics, are used to receive such transmissions, and this fact is made known to the amateur station...
47 CFR 97.121 - Restricted operation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... station causes general interference to the reception of transmissions from stations operating in the domestic broadcast service when receivers of good engineering design, including adequate selectivity characteristics, are used to receive such transmissions, and this fact is made known to the amateur station...
47 CFR 97.121 - Restricted operation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... station causes general interference to the reception of transmissions from stations operating in the domestic broadcast service when receivers of good engineering design, including adequate selectivity characteristics, are used to receive such transmissions, and this fact is made known to the amateur station...
Ellakwa, Hamed E; Sanad, Zakaria F; Hamza, Haitham A; Emara, Mohamed A; Elsayed, Mohamed A
2016-04-01
To identify predictors of clomiphene citrate-induced ovulation in patients with polycystic ovary syndrome (PCOS). A prospective observational study of patients 18-40 years of age with PCOS experiencing infertility was conducted at Menoufia University Hospital between January 2011 and January 2013. A range of potential predictors of ovulation were recorded before patients received a 50-mg dose of clomiphene citrate. Following ovulation or no response to increasing clomiphene-citrate doses, correlations between predictors and treatment responses were analyzed. In total, 150 patients with PCOS experiencing infertility were enrolled. Following treatment, 110 (73.3%) patients ovulated. Highly significant differences were observed between treatment responders and non-responders in baseline amenorrhea, body mass index (BMI), waist circumference, total testosterone, anti-Müllerian hormone, fasting insulin, homeostatic model assessment of insulin resistance, and visceral fat area (P<0.001). Significant differences in mean ovarian volume (P<0.009) and ovarian stromal artery pulsatility index (P<0.003) were also observed. Total testosterone was the best individual predictor of clomiphene citrate treatment response. The area under the receiver operating characteristic curve in a multivariate prediction model was 0.98. A combination of patient amenorrhea, BMI, total testosterone, anti-Müllerian hormone, ovarian volume, ovarian stromal artery pulsatility index, and visceral fat area could be used to predict clomiphene-citrate treatment response in patients with PCOS experiencing infertility. ClinicalTrials.gov: NCT02269306. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
Review of laparoscopic training in pediatric surgery in the United Kingdom.
Stormer, Emma J; Sabharwal, Atul J
2009-04-01
To review the exposure pediatric surgery trainees have to laparoscopic surgery in the United Kingdom (UK). A confidential postal questionnaire was sent to all trainees working at registrar level in centers responsible for pediatric surgical training in the UK. Questions assessed the number of consultants with an interest in laparoscopic surgery, types of cases performed laparoscopically, and trainees' role in laparoscopic appendicectomy (LA). Questionnaires were sent to 112 trainees with a 55% response rate (62 replies). At least one response was received from each unit. Based on responses, 49 to 67 consultants in 21 training centers have an interest in laparoscopic surgery (0%-100% of consultants per unit). LA was offered in 20 out of 21 training centers. There was no significant difference in the proportion of appendicectomies performed laparoscopically by junior (years 1-3) and senior (years 4-6) trainees. A significantly higher proportion of junior trainees had not performed any LAs (P = 0.02). Seventy-three percent of trainees were the principal operator. For trainees who were principal operators, the cameraperson was a consultant in 52% and a junior trainee in 17%. The time of day affected the likelihood of a procedure being carried out laparoscopically in 43 (81%) responses. The majority of trainees' exposure to laparoscopic surgery could be viewed as suboptimal; however, the exposure gained varies significantly between different units throughout the UK. In an age moving in favor of minimal access surgery, all units must be in a position to offer pediatric laparoscopic surgical training.
The behavioural response of migrating humpback whales to a full seismic airgun array.
Dunlop, Rebecca A; Noad, Michael J; McCauley, Robert D; Kniest, Eric; Slade, Robert; Paton, David; Cato, Douglas H
2017-12-20
Despite concerns on the effects of noise from seismic survey airguns on marine organisms, there remains uncertainty as to the biological significance of any response. This study quantifies and interprets the response of migrating humpback whales ( Megaptera novaeangliae ) to a 3130 in 3 (51.3l) commercial airgun array. We compare the behavioural responses to active trials (array operational; n = 34 whale groups), with responses to control trials (source vessel towing the array while silent; n = 33) and baseline studies of normal behaviour in the absence of the vessel ( n = 85). No abnormal behaviours were recorded during the trials. However, in response to the active seismic array and the controls , the whales displayed changes in behaviour. Changes in respiration rate were of a similar magnitude to changes in baseline groups being joined by other animals suggesting any change group energetics was within their behavioural repertoire. However, the reduced progression southwards in response to the active treatments, for some cohorts, was below typical migratory speeds. This response was more likely to occur within 4 km from the array at received levels over 135 dB re 1 µPa 2 s. © 2017 The Author(s).
Effects of channel tap spacing on delay-lock tracking
NASA Astrophysics Data System (ADS)
Dana, Roger A.; Milner, Brian R.; Bogusch, Robert L.
1995-12-01
High fidelity simulations of communication links operating through frequency selective fading channels require both accurate channel models and faithful reproduction of the received signal. In modern radio receivers, processing beyond the analog-to-digital converter (A/D) is done digitally, so a high fidelity simulation is actually an emulation of this digital signal processing. The 'simulation' occurs in constructing the output of the A/D. One approach to constructing the A/D output is to convolve the channel impulse response function with the combined impulse response of the transmitted modulation and the A/D. For both link simulations and hardware channel simulators, the channel impulse response function is then generated with a finite number of samples per chip, and the convolution is implemented in a tapped delay line. In this paper we discuss the effects of the channel model tap spacing on the performance of delay locked loops (DLLs) in both direct sequence and frequency hopped spread spectrum systems. A frequency selective fading channel is considered, and the channel impulse response function is constructed with an integer number of taps per modulation symbol or chip. The tracking loop time delay is computed theoretically for this tapped delay line channel model and is compared to the results of high fidelity simulations of actual DLLs. A surprising result is obtained. The performance of the DLL depends strongly on the number of taps per chip. As this number increases the DLL delay approaches the theoretical limit.
Fuchs, Friederike; Schillinger, Daniela; Atreya, Raja; Hirschmann, Simon; Fischer, Sarah; Neufert, Clemens; Atreya, Imke; Neurath, Markus F; Zundler, Sebastian
2017-01-01
Despite large clinical success, deeper insights into the immunological effects of vedolizumab therapy for inflammatory bowel diseases are scarce. In particular, the reasons for differential clinical response in individual patients, the precise impact on the equilibrium of integrin-expressing T cell subsets, and possible associations between these issues are not clear. Blood samples from patients receiving clinical vedolizumab therapy were sequentially collected and analyzed for expression of integrins and chemokine receptors on T cells. Moreover, clinical and laboratory data from the patients were collected, and changes between homing marker expression and clinical parameters were analyzed for possible correlations. While no significant correlation of changes in integrin expression and changes in outcome parameters were identified in Crohn's disease (CD), increasing α4β7 levels in ulcerative colitis (UC) seemed to be associated with favorable clinical development, whereas increasing α4β1 and αEβ7 correlated with negative changes in outcome parameters. Changes in α4β1 integrin expression after 6 weeks were significantly different in responders and non-responders to vedolizumab therapy as assessed after 16 weeks with a cutoff of +4.2% yielding 100% sensitivity and 100% specificity in receiver-operator-characteristic analysis. Our data show that clinical response to vedolizumab therapy in UC but not in CD is associated with specific changes in integrin expression profiles opening novel avenues for mechanistic research and possibly prediction of response to therapy.
Ibuprofen timing for hand surgery in ambulatory care
Giuliani, Enrico; Bianchi, Anna; Marcuzzi, Augusto; Landi, Antonio; Barbieri, Alberto
2015-01-01
OBJECTIVE: To evaluate the effect of pre-operative administration of ibuprofen on post-operative pain control vs. early post-operative administration for hand surgery procedures performed under local anaesthesia in ambulatory care. METHODS: Candidates to trigger finger release by De Quervain tenosynovitis and carpal tunnel operation under local anesthesia were enrolled in the study. Group A received 400 mg ibuprofen before the operation and placebo after the procedure; group B received placebo before the operation and ibuprofen 400 mg at the end of the procedure; both groups received ibuprofen 400 mg every 6h thereafter. Visual analogue scale (VAS) was measured at fixed times before and every 6h after surgery, for a total follow-up of 18h. RESULTS: Groups were similar according to age, gender and type of surgery. Median VAS values did not produce any statistical significance, while there was a statistically significant difference on pre-operative and early post-operative VAS values between groups (A -8.53 mm vs. B 3.36 mm, p=0.0085). CONCLUSION: Average pain levels were well controlled by local anesthesia and post-operative ibuprofen analgesia. Pre-operative ibuprofen administration can contribute to improve early pain management. Level of Evidence II, Therapeutic Studies. PMID:26327799
49 CFR 350.207 - What response does a State receive to its CVSP submission?
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false What response does a State receive to its CVSP...) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY... response does a State receive to its CVSP submission? (a) The FMCSA will notify the State, in writing...
49 CFR 350.207 - What response does a State receive to its CVSP submission?
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false What response does a State receive to its CVSP...) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY... response does a State receive to its CVSP submission? (a) The FMCSA will notify the State, in writing...
49 CFR 350.207 - What response does a State receive to its CVSP submission?
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false What response does a State receive to its CVSP...) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY... response does a State receive to its CVSP submission? (a) The FMCSA will notify the State, in writing...
49 CFR 350.207 - What response does a State receive to its CVSP submission?
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false What response does a State receive to its CVSP...) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY... response does a State receive to its CVSP submission? (a) The FMCSA will notify the State, in writing...
49 CFR 350.207 - What response does a State receive to its CVSP submission?
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false What response does a State receive to its CVSP...) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY... response does a State receive to its CVSP submission? (a) The FMCSA will notify the State, in writing...
Performance of DBS-Radio using concatenated coding and equalization
NASA Technical Reports Server (NTRS)
Gevargiz, J.; Bell, D.; Truong, L.; Vaisnys, A.; Suwitra, K.; Henson, P.
1995-01-01
The Direct Broadcast Satellite-Radio (DBS-R) receiver is being developed for operation in a multipath Rayleigh channel. This receiver uses equalization and concatenated coding, in addition to open loop and closed loop architectures for carrier demodulation and symbol synchronization. Performance test results of this receiver are presented in both AWGN and multipath Rayleigh channels. Simulation results show that the performance of the receiver operating in a multipath Rayleigh channel is significantly improved by using equalization. These results show that fractional-symbol equalization offers a performance advantage over full symbol equalization. Also presented is the base-line performance of the DBS-R receiver using concatenated coding and interleaving.
Ransom, Danielle M; Burns, Alison R; Youngstrom, Eric A; Vaughan, Christopher G; Sady, Maegan D; Gioia, Gerard A
2016-11-01
The aim of this study was to demonstrate the utility of an evidence-based assessment (EBA) model to establish a multimodal set of tools for identifying students at risk for perceived post-injury academic problems. Participants included 142 students diagnosed with concussion (age: M=14.95; SD=1.80; 59% male), evaluated within 4 weeks of injury (median=16 days). Demographics, pre-injury history, self- and parent-report measures assessing symptom severity and executive functions, and cognitive test performance were examined as predictors of self-reported post-injury academic problems. Latent class analysis categorized participants into "high" (44%) and "low" (56%) levels of self-reported academic problems. Receiver operating characteristic analyses revealed significant discriminative validity for self- and parent-reported symptom severity and executive dysfunction and self-reported exertional response for identifying students reporting low versus high academic problems. Parent-reported symptom ratings [area under the receiver operating characteristic curve (AUC)=.79] and executive dysfunction (AUC=.74), and self-reported ratings of executive dysfunction (AUC=.84), symptoms (AUC=.80), and exertional response (AUC=.70) each classified students significantly better than chance (ps<.001). Hierarchical logistic regression indicated that, of the above, self-reported symptoms and executive dysfunction accounted for the most variance in the prediction of self-reported academic problems. Post-concussion symptom severity and executive dysfunction significantly predict perceived post-injury academic problems. EBA modeling identified the strongest set of predictors of academic challenges, offering an important perspective in the management of concussion by applying traditional strengths of neuropsychological assessment to clinical decision making. (JINS, 2016, 22, 1038-1049).
Srey, Chandra S; Maddux, Jean-Marie N; Chaudhri, Nadia
2015-01-01
Environmental stimuli that are reliably paired with alcohol may acquire incentive salience, a property that can operate in the use and abuse of alcohol. Here we investigated the incentive salience of Pavlovian alcohol cues using a preclinical animal model. Male, Long-Evans rats (Harlan) with unrestricted access to food and water were acclimated to drinking 15% ethanol (v/v) in their home-cages. Rats then received Pavlovian autoshaping training in which the 10 s presentation of a retractable lever served as the conditioned stimulus (CS) and 15% ethanol served as the unconditioned stimulus (US) (0.2 ml/CS; 12 CS presentations/session; 27 sessions). Next, in an operant test of conditioned reinforcement, nose pokes into an active aperture delivered presentations of the lever-CS, whereas nose pokes into an inactive aperture had no consequences. Across initial autoshaping sessions, goal-tracking behavior, as measured by entries into the fluid port where ethanol was delivered, developed rapidly. However, with extended training goal-tracking diminished, and sign-tracking responses, as measured by lever-CS activations, emerged. Control rats that received explicitly unpaired CS and US presentations did not show goal-tracking or sign-tracking responses. In the test for conditioned reinforcement, rats with CS-US pairings during autoshaping training made more active relative to inactive nose pokes, whereas rats in the unpaired control group did not. Moreover, active nose pokes were positively correlated with sign-tracking behavior during autoshaping. Extended training may produce a shift in the learned properties of Pavlovian alcohol cues, such that after initially predicting alcohol availability they acquire robust incentive salience.
Friton, Gabriele; Thompson, Caryn Marie; Karadzovska, Daniela; King, Stephen; King, Jonathan N
2017-06-26
Non-steroidal anti-inflammatory drugs (NSAIDs) have been proven to be effective in controlling peri-operative pain in dogs. Robenacoxib is an NSAID with high selectivity for the cyclooxygenase (COX)-2 isoform. The objective of this study was to assess the efficacy and safety of an oral tablet formulation of robenacoxib in client-owned dogs undergoing soft tissue surgery. The study was a prospective, multi-center, randomized, masked, placebo-controlled, parallel-group clinical trial. A total of 239 dogs were included and randomly allocated in a 1:1 ratio to receive either robenacoxib or placebo. Each dog received an oral tablet administration of either robenacoxib, at a target dose of 2 mg/kg, or placebo once prior to surgery and for two additional days post-operatively. All dogs also received a pre-anesthetic dose of 0.2 mg/kg butorphanol (intravenous or intramuscular). Pain assessments were performed using the short form of the Glasgow Composite Measure Pain Scale. Robenacoxib was compared to the placebo group on a success/failure basis. Treatment failure was defined as the need for rescue therapy to control post-operative pain. Significantly (P = 0.019) more dogs administered robenacoxib were considered treatment successes (89 of 116, 76.72%) compared to dogs given placebo (74 of 115, 64.35%). The percentage of treatment failure was therefore 23.28% in the robenacoxib and 35.65% in the placebo group. The least squares mean total pain scores were significantly different between groups and in favor of robenacoxib at 3 and 5 hours (P < 0.05) and 8 hours post-extubation (P < 0.01). Pain at the surgery sites (response to touch) was also significantly improved at 3, 5 and 8 hours post-extubation in dogs receiving robenacoxib versus placebo (P < 0.01). In addition, a significant overall improvement in posture/activity was revealed with robenacoxib having lower scores versus placebo (P < 0.01). No significant differences between the robenacoxib and placebo groups in the frequency of reported adverse events were observed. Robenacoxib by oral (tablet) administration was effective and well tolerated in the control of peri-operative pain and inflammation associated with soft tissue surgery in dogs.
Chansirinukor, Wunpen; Maher, Christopher G; Latimer, Jane; Hush, Julia
2005-01-01
Retrospective design. To compare the responsiveness and test-retest reliability of the Functional Rating Index and the 18-item version of the Roland-Morris Disability Questionnaire in detecting change in disability in patients with work-related low back pain. Many low back pain-specific disability questionnaires are available, including the Functional Rating Index and the 18-item version of the Roland-Morris Disability Questionnaire. No previous study has compared the responsiveness and reliability of these questionnaires. Files of patients who had been treated for work-related low back pain at a physical therapy clinic were reviewed, and those containing initial and follow-up Functional Rating Index and 18-item Roland-Morris Disability Questionnaires were selected. The responsiveness of both questionnaires was compared using two different methods. First, using the assumption that patients receiving treatment improve over time, various responsiveness coefficients were calculated. Second, using change in work status as an external criterion to identify improved and nonimproved patients, Spearman's rho and receiver operating characteristic curves were calculated. Reliability was estimated from the subset of patients who reported no change in their condition over this period and expressed with the intraclass correlation coefficient and the minimal detectable change. One hundred and forty-three patient files were retrieved. The responsiveness coefficients for the Functional Rating Index were greater than for the 18-item Roland-Morris Disability Questionnaire. The intraclass correlation coefficient values for both questionnaires calculated from 96 patient files were similar, but the minimal detectable change for the Functional Rating Index was less than for the 18-item Roland-Morris Disability Questionnaire. The Functional Rating Index seems preferable to the 18-item Roland-Morris Disability Questionnaire for use in clinical trials and clinical practice.
NASA Technical Reports Server (NTRS)
Grant, T. L.
1978-01-01
A hybrid receiver has been designed for the Galileo Project. The receiver, located on the Galileo Orbiter, will autonomously acquire and track signals from the first atmospheric probe of Jupiter as well as demodulate, bit-synchronize, and buffer the telemetry data. The receiver has a conventional RF and LF front end but performs multiple functions digitally under firmware control. It will be a self-acquiring receiver that operates under a large frequency uncertainty; it can accommodate different modulation types, bit rates, and other parameter changes via reprogramming. A breadboard receiver and test set demonstrate a preliminary version of the sequential detection process and verify the hypothesis that a fading channel does not reduce the probability of detection.
Kuo, Pao-Jen; Wu, Shao-Chun; Chien, Peng-Chen; Chang, Shu-Shya; Rau, Cheng-Shyuan; Tai, Hsueh-Ling; Peng, Shu-Hui; Lin, Yi-Chun; Chen, Yi-Chun; Hsieh, Hsiao-Yun; Hsieh, Ching-Hua
2018-03-02
The aim of this study was to develop an effective surgical site infection (SSI) prediction model in patients receiving free-flap reconstruction after surgery for head and neck cancer using artificial neural network (ANN), and to compare its predictive power with that of conventional logistic regression (LR). There were 1,836 patients with 1,854 free-flap reconstructions and 438 postoperative SSIs in the dataset for analysis. They were randomly assigned tin ratio of 7:3 into a training set and a test set. Based on comprehensive characteristics of patients and diseases in the absence or presence of operative data, prediction of SSI was performed at two time points (pre-operatively and post-operatively) with a feed-forward ANN and the LR models. In addition to the calculated accuracy, sensitivity, and specificity, the predictive performance of ANN and LR were assessed based on area under the curve (AUC) measures of receiver operator characteristic curves and Brier score. ANN had a significantly higher AUC (0.892) of post-operative prediction and AUC (0.808) of pre-operative prediction than LR (both P <0.0001). In addition, there was significant higher AUC of post-operative prediction than pre-operative prediction by ANN (p<0.0001). With the highest AUC and the lowest Brier score (0.090), the post-operative prediction by ANN had the highest overall predictive performance. The post-operative prediction by ANN had the highest overall performance in predicting SSI after free-flap reconstruction in patients receiving surgery for head and neck cancer.
Yang, F-Y; Bao, Y-Z; Liu, F-S; Zhu, Y-C; Zheng, J; Zhang, J-H; Zheng, X-F; Wei, G-C
2015-04-01
The objective of this study was to compare coronary artery bypass graft (CABG) surgery with non-extracorporeal vs. extracorporeal circulation. The study outcomes included operative time, number of graft vessels, pulmonary infection rates, and systemic inflammatory markers. 96 patients received selective CABG, either with non-extracorporeal (study group; n = 48) or extracorporeal circulation (control group; n = 48). Operative time, pulmonary infection rates, and blood levels of inflammatory markers TNF-α, IL-6, and IL-8 before and 4, 24, and 48 hours after the surgery were quantified. Graft vessels were quantified using computed tomography. Operative time was significantly shorter in study group (4.58 ± 0.91 vs. 5.36 ± 1.12 hours in control group; p < 0.05). The number of graft vessels and pulmonary infection rates were comparable between both techniques. However, systemic inflammatory markers were significantly (p < 0.05) lower in study group at 4 and, partly, 24 hours after the surgery. Extracorporeal circulation prolongs operation and can aggravate systemic inflammatory response. Therefore, CABG with non-extracorporeal circulation offers more beneficial outcomes.
Testosterone regulates bone response to inflammation.
Steffens, J P; Herrera, B S; Coimbra, L S; Stephens, D N; Rossa, C; Spolidorio, L C; Kantarci, A; Van Dyke, T E
2014-03-01
This study evaluated the alveolar bone response to testosterone and the impact of Resolvin D2 (RvD2) on testosterone-induced osteoblast function. For the in vivo characterization, 60 male adult rats were used. Treatments established sub-physiologic (L), normal (N), or supra-physiologic (H) concentrations of testosterone. Forty rats were subjected to orchiectomy; 20 rats received periodical testosterone injections while 20 rats received testicular sham-operation. Four weeks after the surgeries, 10 rats in each group received a subgingival ligature around the lower first molars to induce experimental periodontal inflammation and bone loss. In parallel, osteoblasts were differentiated from neonatal mice calvariae and treated with various doses of testosterone for 48 h. Cell lysates and conditioned media were used for the determination of alkaline phosphatase, osteocalcin, RANKL, and osteoprotegerin. Micro-computed tomography linear analysis demonstrated that bone loss was significantly increased for both L and H groups compared to animals with normal levels of testosterone. Gingival IL-1β expression was increased in the L group (p<0.05). Ten nM testosterone significantly decreased osteocalcin, RANKL, and OPG levels in osteoblasts; 100 nM significantly increased the RANKL:OPG ratio. RvD2 partially reversed the impact of 10 nM testosterone on osteocalcin, RANKL, and OPG. These findings suggest that both L and H testosterone levels increase inflammatory bone loss in male rats. While low testosterone predominantly increases the inflammatory response, high testosterone promotes a higher osteoblast-derived RANKL:OPG ratio. The proresolving mediator RvD2 ameliorates testosterone-derived downregulation of osteocalcin, RANKL, and OPG in primary murine osteoblasts suggesting a direct role of inflammation in osteoblast function. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Sekiya, N.
2016-08-01
We have developed two high-order high-temperature superconducting (HTS) dual-band bandpass filters (BPFs) with a receiver subsystem for future mobile communication systems. They feature stub-loaded hair-pin resonators with two types of microstrip lines between them. One has a six-pole design, and the other has an eight-pole design. Both were designed to operate at 2.15 GHz with a 43-MHz (2%) bandwidth for the lower passband and at 3.50 GHz with a 70-MHz (2%) bandwidth for the upper one. They were fabricated using YBa2Cu3Oy thin film on a CeO2-bufferd r-Al2O3 substrate. The measured results for both filters agree well with the simulated ones. The HTS dual-band BPF receiver subsystem uses a pulse tube cryocooler and a wideband low noise amplifier (LNA). We measured the frequency response of the six-pole dual-band BPF with and without a wideband LNA with a gain of 10 dB. The measured return losses were close.
Creep life management system for a turbine engine and method of operating the same
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tralshawala, Nilesh; Miller, Harold Edward; Badami, Vivek Venugopal
A creep life management system includes at least one sensor apparatus coupled to a first component. The at least one sensor apparatus is configured with a unique identifier. The creep life management system also includes at least one reader unit coupled to a second component. The at least one reader unit is configured to transmit an interrogation request signal to the at least one sensor apparatus and receive a measurement response signal transmitted from the at least one sensor apparatus. The creep life management system further includes at least one processor programmed to determine a real-time creep profile of themore » first component as a function of the measurement response signal transmitted from the at least one sensor apparatus.« less
Detection of Carbon Monoxide Using Polymer-Carbon Composite Films
NASA Technical Reports Server (NTRS)
Homer, Margie L.; Ryan, Margaret A.; Lara, Liana M.
2011-01-01
A carbon monoxide (CO) sensor was developed that can be incorporated into an existing sensing array architecture. The CO sensor is a low-power chemiresistor that operates at room temperature, and the sensor fabrication techniques are compatible with ceramic substrates. Sensors made from four different polymers were tested: poly (4-vinylpryridine), ethylene-propylene-diene-terpolymer, polyepichlorohydrin, and polyethylene oxide (PEO). The carbon black used for the composite films was Black Pearls 2000, a furnace black made by the Cabot Corporation. Polymers and carbon black were used as received. In fact, only two of these sensors showed a good response to CO. The poly (4-vinylpryridine) sensor is noisy, but it does respond to the CO above 200 ppm. The polyepichlorohydrin sensor is less noisy and shows good response down to 100 ppm.
Pulse oximeter as a sensor of fluid responsiveness: do we have our finger on the best solution?
Monnet, Xavier; Lamia, Bouchra; Teboul, Jean-Louis
2005-01-01
The pulse oximetry plethysmographic signal resembles the peripheral arterial pressure waveform, and the degree of respiratory variation in the pulse oximetry wave is close to the degree of respiratory arterial pulse pressure variation. Thus, it is tempting to speculate that pulse oximetry can be used to assess preload responsiveness in mechanically ventilated patients. In this commentary we briefly review the complex meaning of the pulse oximetry plethysmographic signal and highlight the advantages, limitations and pitfalls of the pulse oximetry method. Future studies including volume challenge must be performed to test whether the pulse oximetry waveform can really serve as a nonivasive tool for the guidance of fluid therapy in patients receiving mechanical ventilation in intensive care units and in operating rooms. PMID:16277729
Receiver System: Lessons Learned from Solar Two
NASA Astrophysics Data System (ADS)
Litwin, R. Z.
2002-03-01
The Boeing Company fabricated the Solar Two receiver as a subcontractor for the Solar Two project. The receiver absorbed sunlight reflected from the heliostat field. A molten-nitrate-salt heat transfer fluid was pumped from a storage tank at grade level, heated from 290 to 565DGC by the receiver mounted on top of a tower, then flowed back down into another storage tank. To make electricity, the hot salt was pumped through a steam generator to produce steam that powered a conventional Rankine steam turbine/generator. This evaluation identifies the most significant Solar Two receiver system lessons learned from the Mechanical Design, Instrumentation and Control, Panel Fabrication, Site Construction, Receiver System Operation, and Management from the perspective of the receiver designer/manufacturer. The lessons learned on the receiver system described here consist of two parts: the Problem and one or more identified Solutions. The appendix summarizes an inspection of the advanced receiver panel developed by Boeing that was installed and operated in the Solar Two receiver.
Receiver System: Lessons Learned From Solar Two
DOE Office of Scientific and Technical Information (OSTI.GOV)
LITWIN, ROBERT Z.; PACHECO, JAMES E.
The Boeing Company fabricated the Solar Two receiver as a subcontractor for the Solar Two project. The receiver absorbed sunlight reflected from the heliostat field. A molten-nitrate-salt heat transfer fluid was pumped from a storage tank at grade level, heated from 290 to 565 C by the receiver mounted on top of a tower, then flowed back down into another storage tank. To make electricity, the hot salt was pumped through a steam generator to produce steam that powered a conventional Rankine steam turbine/generator. This evaluation identifies the most significant Solar Two receiver system lessons learned from the Mechanical Design,more » Instrumentation and Control, Panel Fabrication, Site Construction, Receiver System Operation, and Management from the perspective of the receiver designer/manufacturer. The lessons learned on the receiver system described here consist of two parts: the Problem and one or more identified Solutions. The appendix summarizes an inspection of the advanced receiver panel developed by Boeing that was installed and operated in the Solar Two receiver.« less
Karichappan, Thirugnanasambandham; Venkatachalam, Sivakumar; Jeganathan, Prakash Maran
2014-01-10
Discharge of grey wastewater into the ecological system causes the negative impact effect on receiving water bodies. In this present study, electrocoagulation process (EC) was investigated to treat grey wastewater under different operating conditions such as initial pH (4-8), current density (10-30 mA/cm2), electrode distance (4-6 cm) and electrolysis time (5-25 min) by using stainless steel (SS) anode in batch mode. Four factors with five levels Box-Behnken response surface design (BBD) was employed to optimize and investigate the effect of process variables on the responses such as total solids (TS), chemical oxygen demand (COD) and fecal coliform (FC) removal. The process variables showed significant effect on the electrocoagulation treatment process. The results were analyzed by Pareto analysis of variance (ANOVA) and second order polynomial models were developed in order to study the electrocoagulation process statistically. The optimal operating conditions were found to be: initial pH of 7, current density of 20 mA/cm2, electrode distance of 5 cm and electrolysis time of 20 min. These results indicated that EC process can be scale up in large scale level to treat grey wastewater with high removal efficiency of TS, COD and FC.
Load-induced modulation of signal transduction networks.
Jiang, Peng; Ventura, Alejandra C; Sontag, Eduardo D; Merajver, Sofia D; Ninfa, Alexander J; Del Vecchio, Domitilla
2011-10-11
Biological signal transduction networks are commonly viewed as circuits that pass along information--in the process amplifying signals, enhancing sensitivity, or performing other signal-processing tasks--to transcriptional and other components. Here, we report on a "reverse-causality" phenomenon, which we call load-induced modulation. Through a combination of analytical and experimental tools, we discovered that signaling was modulated, in a surprising way, by downstream targets that receive the signal and, in doing so, apply what in physics is called a load. Specifically, we found that non-intuitive changes in response dynamics occurred for a covalent modification cycle when load was present. Loading altered the response time of a system, depending on whether the activity of one of the enzymes was maximal and the other was operating at its minimal rate or whether both enzymes were operating at submaximal rates. These two conditions, which we call "limit regime" and "intermediate regime," were associated with increased or decreased response times, respectively. The bandwidth, the range of frequency in which the system can process information, decreased in the presence of load, suggesting that downstream targets participate in establishing a balance between noise-filtering capabilities and a circuit's ability to process high-frequency stimulation. Nodes in a signaling network are not independent relay devices, but rather are modulated by their downstream targets.
Quantifying the tracking capability of space-based AIS systems
NASA Astrophysics Data System (ADS)
Skauen, Andreas Nordmo
2016-01-01
The Norwegian Defence Research Establishment (FFI) has operated three Automatic Identification System (AIS) receivers in space. Two are on dedicated nano-satellites, AISSat-1 and AISSat-2. The third, the NORAIS Receiver, was installed on the International Space Station. A general method for calculating the upper bound on the tracking capability of a space-based AIS system has been developed and the results from the algorithm applied to AISSat-1 and the NORAIS Receiver individually. In addition, a constellation of AISSat-1 and AISSat-2 is presented. The tracking capability is defined as the probability of re-detecting ships as they move around the globe and is explained to represent and upper bound on a space-based AIS system performance. AISSat-1 and AISSat-2 operates on the nominal AIS1 and AIS2 channels, while the NORAIS Receiver data used are from operations on the dedicated space AIS channels, AIS3 and AIS4. The improved tracking capability of operations on the space AIS channels is presented.
NASA Astrophysics Data System (ADS)
Hefni, Baligh El; Bourdil, Charles
2017-06-01
Molten salt technology represents nowadays the most cost-effective technology for electricity generation for solar power plant. The molten salt tower receiver is based on a field of individually sun-tracking mirrors (heliostats) that reflect the incident sunshine to a receiver at the top of a centrally located tower. The objective of this study is to assess the impact of several transients issued from different scenarios (failure or normal operation mode) on the receiver dynamic behavior. A dynamic detailed model of Solar Two molten salt central receiver has been developed. The component model is meant to be used for receiver modeling with the ThermoSysPro library, developed by EDF. The paper also gives the results of the dynamic simulation for the selected scenarios on Solar Two receiver.
Reconfigurable Auditory-Visual Display
NASA Technical Reports Server (NTRS)
Begault, Durand R. (Inventor); Anderson, Mark R. (Inventor); McClain, Bryan (Inventor); Miller, Joel D. (Inventor)
2008-01-01
System and method for visual and audible communication between a central operator and N mobile communicators (N greater than or equal to 2), including an operator transceiver and interface, configured to receive and display, for the operator, visually perceptible and audibly perceptible signals from each of the mobile communicators. The interface (1) presents an audible signal from each communicator as if the audible signal is received from a different location relative to the operator and (2) allows the operator to select, to assign priority to, and to display, the visual signals and the audible signals received from a specified communicator. Each communicator has an associated signal transmitter that is configured to transmit at least one of the visual signals and the audio signal associated with the communicator, where at least one of the signal transmitters includes at least one sensor that senses and transmits a sensor value representing a selected environmental or physiological parameter associated with the communicator.
A 128-Tap Highly Tunable CMOS IF Finite Impulse Response Filter for Pulsed Radar Applications
Mincey, John Stephen; Su, Eric C.; Silva-Martinez, Jose; ...
2018-02-28
A configurable-bandwidth (BW) filter is presented in this paper for pulsed radar applications. Also, to eliminate dispersion effects in the received waveform, a finite impulse response (FIR) topology is proposed, which has a measured standard deviation of an in-band group delay of 11 ns that is primarily dominated by the inherent, fully predictable delay introduced by the sample-and-hold. The filter operates at an IF of 20 MHz, and is tunable in BW from 1.5 to 15 MHz, which makes it optimal to be used with varying pulse widths in the radar. Employing a total of 128 taps, the FIR filtermore » provides greater than 50-dB sharp attenuation in the stopband in order to minimize all out-of-band noise in the low signal-to-noise received radar signal. Fabricated in a 0.18-μm silicon on insulator CMOS process, the proposed filter consumes approximately 3.5 mW/tap with a 1.8-V supply. Finally, a 20-MHz two-tone measurement with 200-kHz tone separation shows IIP3 greater than 8.5 dBm.« less
Monaural Sound Localization Based on Reflective Structure and Homomorphic Deconvolution
Park, Yeonseok; Choi, Anthony
2017-01-01
The asymmetric structure around the receiver provides a particular time delay for the specific incoming propagation. This paper designs a monaural sound localization system based on the reflective structure around the microphone. The reflective plates are placed to present the direction-wise time delay, which is naturally processed by convolutional operation with a sound source. The received signal is separated for estimating the dominant time delay by using homomorphic deconvolution, which utilizes the real cepstrum and inverse cepstrum sequentially to derive the propagation response’s autocorrelation. Once the localization system accurately estimates the information, the time delay model computes the corresponding reflection for localization. Because of the structure limitation, two stages of the localization process perform the estimation procedure as range and angle. The software toolchain from propagation physics and algorithm simulation realizes the optimal 3D-printed structure. The acoustic experiments in the anechoic chamber denote that 79.0% of the study range data from the isotropic signal is properly detected by the response value, and 87.5% of the specific direction data from the study range signal is properly estimated by the response time. The product of both rates shows the overall hit rate to be 69.1%. PMID:28946625
A 128-Tap Highly Tunable CMOS IF Finite Impulse Response Filter for Pulsed Radar Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mincey, John Stephen; Su, Eric C.; Silva-Martinez, Jose
A configurable-bandwidth (BW) filter is presented in this paper for pulsed radar applications. Also, to eliminate dispersion effects in the received waveform, a finite impulse response (FIR) topology is proposed, which has a measured standard deviation of an in-band group delay of 11 ns that is primarily dominated by the inherent, fully predictable delay introduced by the sample-and-hold. The filter operates at an IF of 20 MHz, and is tunable in BW from 1.5 to 15 MHz, which makes it optimal to be used with varying pulse widths in the radar. Employing a total of 128 taps, the FIR filtermore » provides greater than 50-dB sharp attenuation in the stopband in order to minimize all out-of-band noise in the low signal-to-noise received radar signal. Fabricated in a 0.18-μm silicon on insulator CMOS process, the proposed filter consumes approximately 3.5 mW/tap with a 1.8-V supply. Finally, a 20-MHz two-tone measurement with 200-kHz tone separation shows IIP3 greater than 8.5 dBm.« less
Global Positioning System Synchronized Active Light Autonomous Docking System
NASA Technical Reports Server (NTRS)
Howard, Richard T. (Inventor); Book, Michael L. (Inventor); Bryan, Thomas C. (Inventor); Bell, Joseph L. (Inventor)
1996-01-01
A Global Positioning System Synchronized Active Light Autonomous Docking System (GPSSALADS) for automatically docking a chase vehicle with a target vehicle comprising at least one active light emitting target which is operatively attached to the target vehicle. The target includes a three-dimensional array of concomitantly flashing lights which flash at a controlled common frequency. The GPSSALADS further comprises a visual tracking sensor operatively attached to the chase vehicle for detecting and tracking the target vehicle. Its performance is synchronized with the flash frequency of the lights by a synchronization means which is comprised of first and second internal clocks operatively connected to the active light target and visual tracking sensor, respectively, for providing timing control signals thereto, respectively. The synchronization means further includes first and second Global Positioning System receivers operatively connected to the first and second internal clocks, respectively, for repeatedly providing simultaneous synchronization pulses to the internal clocks, respectively. In addition, the GPSSALADS includes a docking process controller means which is operatively attached to the chase vehicle and is responsive to the visual tracking sensor for producing commands for the guidance and propulsion system of the chase vehicle.
Global Positioning System Synchronized Active Light Autonomous Docking System
NASA Technical Reports Server (NTRS)
Howard, Richard (Inventor)
1994-01-01
A Global Positioning System Synchronized Active Light Autonomous Docking System (GPSSALADS) for automatically docking a chase vehicle with a target vehicle comprises at least one active light emitting target which is operatively attached to the target vehicle. The target includes a three-dimensional array of concomitantly flashing lights which flash at a controlled common frequency. The GPSSALADS further comprises a visual tracking sensor operatively attached to the chase vehicle for detecting and tracking the target vehicle. Its performance is synchronized with the flash frequency of the lights by a synchronization means which is comprised of first and second internal clocks operatively connected to the active light target and visual tracking sensor, respectively, for providing timing control signals thereto, respectively. The synchronization means further includes first and second Global Positioning System receivers operatively connected to the first and second internal clocks, respectively, for repeatedly providing simultaneous synchronization pulses to the internal clocks, respectively. In addition, the GPSSALADS includes a docking process controller means which is operatively attached to the chase vehicle and is responsive to the visual tracking sensor for producing commands for the guidance and propulsion system of the chase vehicle.
Eat Smart! Ontario's Healthy Restaurant Program: a survey of participating restaurant operators.
Macaskill, Lesley A; Dwyer, John J M; Uetrecht, Connie L; Dombrow, Carol
2003-01-01
Eat Smart! Ontario's Healthy Restaurant Program is a standard provincial health promotion program. Public health units grant an award of excellence to restaurants that meet designated standards in nutrition, food safety, and non-smoking seating. The purpose of this study was to assess whether program objectives for participating restaurant operators were achieved during the first year of program implementation, and to obtain operators' recommendations for improving the program. Dillman's tailored design method was used to design a mail survey and implement it among participating operators (n = 434). The design method, which consisted of four mail-outs, yielded a 74% response rate. Fifty percent of respondents operated family-style or quick-service restaurants, and 82% of respondents learned about the program from public health inspectors. Almost all respondents (98%) participated in the program mainly to have their establishments known as clean and healthy restaurants, 65% received and used either point-of-purchase table stands or postcards to promote the program, and 98% planned to continue participating. The respondents' suggestions for improving the program were related to the award ceremony and program materials, media promotion, communication, education, and program standards. Program staff can use the findings to enhance the program.
Activities at the JSC Payload Operations Control Center During Spacelab Mission
NASA Technical Reports Server (NTRS)
1984-01-01
During a Spacelab flight, the hub of activity was the Payload Operations Control Center (POCC) at the Johnson Space Flight Center (JSC) in Houston, Texas. The POCC became home to the management and science teams who worked around the clock to guide and support the mission. All Spacelab principal investigators and their teams of scientists and engineers set up work areas in the POCC. Through the use of computers, they could send commands to their instruments and receive and analyze experiment data. Instantaneous video and audio communications made it possible for scientists on the ground to follow the progress of their research almost as if they were in space with the crew. This real-time interaction between investigators on the ground and the crew in space was probably the most exciting of Spacelab's many capabilities. As principal investigators talked to the payload specialists during the mission, they consulted on experiment operations, made decisions, and shared in the thrill of gaining new knowledge. In December 1990, a newly-established POCC at the Marshall Space Flight Center (MSFC) opened its door for the operations of the Spacelab payloads and experiments, while JSC monitored the Shuttle flight operations. MSFC had managing responsibilities for the Spacelab missions.
Cruise Ship Plume Tracking Survey Report
NASA Astrophysics Data System (ADS)
2002-09-01
The U. S. Environmental Protection Agency (EPA) is developing a Cruise Ship Discharge Assessment Report in response to a petition the agency received in March 2000. The petition requested that EPA assess and where necessary control discharges from cruise ships. Comments received during public hearings, in 2000, resulted in the EPA agreeing to conduct a survey to assess the discharge plumes resulting from cruise ships, operating in ocean waters off the Florida coast and to compare the results to the Alaska dispersion models. This survey report describes the daily activities of August 2001 Cruise Ship Plume Tracking Survey, and provides a synopsis of the observations from the survey. It also provides data that can be used to assess dispersion of cruise ship wastewater discharges, while in transit. A description of the survey methods is provided in Section 2. Survey results are presented in Section 3. Findings and conclusions are discussed in Section 4.
On the role of covarying functions in stimulus class formation and transfer of function.
Markham, Rebecca G; Markham, Michael R
2002-01-01
This experiment investigated whether directly trained covarying functions are necessary for stimulus class formation and transfer of function in humans. Initial class training was designed to establish two respondent-based stimulus classes by pairing two visual stimuli with shock and two other visual stimuli with no shock. Next, two operant discrimination functions were trained to one stimulus of each putative class. The no-shock group received the same training and testing in all phases, except no stimuli were ever paired with shock. The data indicated that skin conductance response conditioning did not occur for the shock groups or for the no-shock group. Tests showed transfer of the established discriminative functions, however, only for the shock groups, indicating the formation of two stimulus classes only for those participants who received respondent class training. The results suggest that transfer of function does not depend on first covarying the stimulus class functions. PMID:12507017
Olsen, Jaime A; Thomson, Maurine; O'Connell, Kathleen; Wyatt, Ken
2018-05-24
This retrospective study evaluates the progression-free interval and survival outcomes of 40 canine (Canis familiaris) patients with Patnaik grade II and III mast cell tumours treated with combination vinblastine, prednisolone and toceranib phosphate from 2011 to 2015. Patients were subdivided into three groups; patients who received neoadjuvant therapy for poorly operable lesions, patients who received adjuvant therapy following surgical resection and patients being palliated for gross metastatic disease. Median survival time (MST) for the neoadjuvant group was not reached. Median survival time for the remaining groups was 893 days and 218 days, respectively. This combination demonstrated response in 90% (26/29) patients with measurable disease. The predominant side effects related to this chemotherapy combination were gastrointestinal in origin. Further prospective studies are required to further validate the efficacy of this treatment protocol. © 2018 The Authors Veterinary Medicine and Science Published by John Wiley & Sons Ltd.
Entine, F; Bensimon Etzol, J; Bettencourt, C; Dondey, M; Michel, X; Gagna, G; Gellie, G; Corre, Y; Ugolin, N; Chevillard, S; Amabile, J-C
2018-07-01
Estimation of the dose received by accidentally irradiated victims is based on a tripod: clinical, biological, and physical dosimetry. The DosiKit system is an operational and mobile biodosimetry device allowing the measurement of external irradiation directly on the site of a radiological accident. This tool is based on capillary blood sample and hair follicle collection. The aim is to obtain a whole-body and local-surface dose assessment. This paper is about the technical evaluation of the DosiKit; the analytical process and scientific validation are briefly described. The Toulon exercise scenario was based on a major accident involving the reactor of a nuclear attack submarine. The design of the scenario made it impossible for several players (firefighters, medical team) to leave the area for a long time, and they were potentially exposed to high dose rates. The DosiKit system was fully integrated into a deployable radiological emergency laboratory, and the response to operational needs was very satisfactory.
[Research on infrared safety protection system for machine tool].
Zhang, Shuan-Ji; Zhang, Zhi-Ling; Yan, Hui-Ying; Wang, Song-De
2008-04-01
In order to ensure personal safety and prevent injury accident in machine tool operation, an infrared machine tool safety system was designed with infrared transmitting-receiving module, memory self-locked relay and voice recording-playing module. When the operator does not enter the danger area, the system has no response. Once the operator's whole or part of body enters the danger area and shades the infrared beam, the system will alarm and output an control signal to the machine tool executive element, and at the same time, the system makes the machine tool emergency stop to prevent equipment damaged and person injured. The system has a module framework, and has many advantages including safety, reliability, common use, circuit simplicity, maintenance convenience, low power consumption, low costs, working stability, easy debugging, vibration resistance and interference resistance. It is suitable for being installed and used in different machine tools such as punch machine, pour plastic machine, digital control machine, armor plate cutting machine, pipe bending machine, oil pressure machine etc.
Wideband fixed-tuned SIS receiver for 200-GHz operation
NASA Technical Reports Server (NTRS)
Blundell, Raymond; Tong, Cheuk-Yu E.; Papa, D. Cosmo; Leombruno, R. Louie; Zhang, Xiaolei; Paine, Scott; Stern, Jeffrey A.; Leduc, Henry G.; Bumble, Bruce
1995-01-01
We report on the design and development of a heterodyne receiver, designed to cover the frequency range 176-256 GHz. This receiver incorporates a niobium superconductor-insulator-superconductor (SIS) tunnel junction mixer, which, chiefly for reasons of reliability and ease of operation, is a fixed-tuned waveguide design. On-chip tuning is provided to resonate out the junction's geometric capacitance and produce a good match to the waveguide circuit. Laboratory measurements on the first test receiver indicate that the required input bandwidth (about 40%) is achieved with an average receiver noise temperature of below 50 K. Mixer conversion gain is observed at some frequencies, and the lowest measured receiver noise is less than 30 K. Furthermore, the SIS mixer used in this receiver is of simple construction, is easy to assemble and is therefore a good candidate for duplication.
Dual-Polarization, Sideband-Separating, Balanced Receiver for 1.5 THz
NASA Technical Reports Server (NTRS)
Chattopadhyay, Goutman; Ward, John; Manohara, Harish; Siegel, Peter
2009-01-01
A proposed heterodyne receiver would be capable of detecting electromagnetic radiation in both of two orthogonal linear polarizations, separating sidebands, and providing balanced outputs in a frequency band centered at 1.5 THz with a fractional bandwidth greater than 40 percent. Dual polarization, sideband-separating, and balanced-output receivers are well-known and have been used extensively at frequencies up to about 100 GHz; and there was an earlier proposal for such a receiver for frequencies up to 900 GHz. However, the present proposal represents the first realistic design concept for such a receiver capable of operating above 1 THz. The proposed receiver is intended to be a prototype of mass-producible receiver units, operating at frequencies up to 6 THz, that would be incorporated into highly sensitive heterodyne array instruments to be used in astronomical spectroscopic and imaging studies.
Williams, Benjamin B.; Dong, Ruhong; Nicolalde, Roberto J.; Matthews, Thomas P.; Gladstone, David J.; Demidenko, Eugene; Zaki, Bassem I.; Salikhov, Ildar K.; Lesniewski, Piotr N.; Swartz, Harold M.
2014-01-01
Purpose The ability to estimate individual exposures to radiation following a large attack or incident has been identified as a necessity for rational and effective emergency medical response. In vivo electron paramagnetic resonance (EPR) spectroscopy of tooth enamel has been developed to meet this need. Materials and methods A novel transportable EPR spectrometer, developed to facilitate tooth dosimetry in an emergency response setting, was used to measure upper incisors in a model system, in unirradiated subjects, and in patients who had received total body doses of 2 Gy. Results A linear dose response was observed in the model system. A statistically significant increase in the intensity of the radiation-induced EPR signal was observed in irradiated versus unirradiated subjects, with an estimated standard error of dose prediction of 0.9 + 0.3 Gy. Conclusions These results demonstrate the current ability of in vivo EPR tooth dosimetry to distinguish between subjects who have not been irradiated and those who have received exposures that place them at risk for acute radiation syndrome. Procedural and technical developments to further increase the precision of dose estimation and ensure reliable operation in the emergency setting are underway. With these developments EPR tooth dosimetry is likely to be a valuable resource for triage following potential radiation exposure of a large population. PMID:21696339
Fréchette, Eric; Buck, David A; Kaplan, Brian J; Chung, Theodore D; Shaw, James E; Kachnic, Lisa A; Neifeld, James P
2004-08-01
Neoadjuvant chemotherapy and radiation are being utilized with increasing frequency in the multimodal treatment of esophageal cancer, although their effects on morbidity, mortality, and survival remain unclear. The objective of this study was to determine the outcome of multimodal treatment in patients with localized esophageal cancer treated at a single institution. Between 1995 and 2002, 118 patients underwent treatment for localized esophageal cancer, utilizing surgery alone, chemoradiation alone, or surgery following neoadjuvant chemoradiation. There was no statistically significant difference in morbidity, mortality, or length of stay between the patients who received multimodal therapy when compared to surgery alone. A surgical resection after down-staging was possible in 9 out of 28 patients (32%) with a clinically non-resectable tumor (T4 or M1a). Forty-seven percent of the patients who received neoadjuvant therapy had a complete pathologic response with a 3-year survival of 59% as compared to only 20 months in those patients who did not achieve a complete response (P = 0.037). Neoadjuvant chemotherapy administered concomitantly with conformal radiotherapy can be performed safely in the treatment of esophageal cancer, without increasing the operative morbidity, mortality, or length of stay. The higher complete response rates to neoadjuvant treatment (as compared to other reports) may be due to the use of three-dimensional conformal radiation therapy or the novel use of weekly carboplatin and paclitaxel. Copyright 2004 Wiley-Liss, Inc.
Wan, Cai-Feng; Liu, Xue-Song; Wang, Lin; Zhang, Jie; Lu, Jin-Song; Li, Feng-Hua
2018-06-01
To clarify whether the quantitative parameters of contrast-enhanced ultrasound (CEUS) can be used to predict pathological complete response (pCR) in patients with locally advanced breast cancer receiving neoadjuvant chemotherapy (NAC). Fifty-one patients with histologically proved locally advanced breast cancer scheduled for NAC were enrolled. The quantitative data for CEUS and the tumor diameter were collected at baseline and before surgery, and compared with the pathological response. Multiple logistic regression analysis was performed to examine quantitative parameters at CEUS and the tumor diameter to predict the pCR, and receiver operating characteristic (ROC) curve analysis was used as a summary statistic. Multiple logistic regression analysis revealed that PEAK (the maximum intensity of the time-intensity curve during bolus transit), PEAK%, TTP% (time to peak), and diameter% were significant independent predictors of pCR, and the area under the ROC curve was 0.932(Az 1 ), and the sensitivity and specificity to predict pCR were 93.7% and 80.0%. The area under the ROC curve for the quantitative parameters was 0.927(Az 2 ), and the sensitivity and specificity to predict pCR were 81.2% and 94.3%. For diameter%, the area under the ROC curve was 0.786 (Az 3 ), and the sensitivity and specificity to predict pCR were 93.8% and 54.3%. The values of Az 1 and Az 2 were significantly higher than that of Az 3 (P = 0.027 and P = 0.034, respectively). However, there was no significant difference between the values of Az 1 and Az 2 (P = 0.825). Quantitative analysis of tumor blood perfusion with CEUS is superior to diameter% to predict pCR, and can be used as a functional technique to evaluate tumor response to NAC. Copyright © 2018. Published by Elsevier B.V.
3-dimensional telepresence system for a robotic environment
Anderson, Matthew O.; McKay, Mark D.
2000-01-01
A telepresence system includes a camera pair remotely controlled by a control module affixed to an operator. The camera pair provides for three dimensional viewing and the control module, affixed to the operator, affords hands-free operation of the camera pair. In one embodiment, the control module is affixed to the head of the operator and an initial position is established. A triangulating device is provided to track the head movement of the operator relative to the initial position. A processor module receives input from the triangulating device to determine where the operator has moved relative to the initial position and moves the camera pair in response thereto. The movement of the camera pair is predetermined by a software map having a plurality of operation zones. Each zone therein corresponds to unique camera movement parameters such as speed of movement. Speed parameters include constant speed, or increasing or decreasing. Other parameters include pan, tilt, slide, raise or lowering of the cameras. Other user interface devices are provided to improve the three dimensional control capabilities of an operator in a local operating environment. Such other devices include a pair of visual display glasses, a microphone and a remote actuator. The pair of visual display glasses are provided to facilitate three dimensional viewing, hence depth perception. The microphone affords hands-free camera movement by utilizing voice commands. The actuator allows the operator to remotely control various robotic mechanisms in the remote operating environment.
A national survey of antimicrobial prophylaxis in adult cardiac surgery across Canada
Paradiso-Hardy, Fran L; Cornish, Patti; Pharand, Chantal; Fremes, Stephen E
2002-01-01
OBJECTIVE: To characterize national and regional patterns of antimicrobial prophylaxis in adult cardiac surgery across Canada. DESIGN: Retrospective, cross-sectional analysis. SETTING: Thirty-three adult cardiac surgical centres across Canada. INTERVENTIONS: A one-page questionnaire collecting information regarding institutional demographics and antimicrobial prophylaxis regimens for adult cardiac surgical procedures was mailed to all adult surgical centres across Canada. If a response was not received within one month, a second survey was mailed, followed by a telephone reminder within two weeks of the second mailing. MAIN RESULTS: The Overall response rate was 100%. Prophylactic antimicrobials were used in all the adult cardiac centres; single-agent prophylaxis was used in 97% (32 of 33) of centres; Single-dose antimicrobial prophylaxis was used in only 3% (one of 33) of centres. Preoperative and postoperative antimicrobial prophylaxis regimens varied both between provinces and within provinces across Canada. Cefazolin was the antimicrobial used in 88% (38 of 43) and 87% (33 of 38) of the reported pre-operative and post-operative prophylaxis regimens, respectively. Antimicrobial prophylaxis was initiated in the operating room 72% (26 of 36) of the time and intra-operative supplemental antimicrobial doses were administered for cardiac procedures longer than a median of 4 hours (range 4 to 8 hr). Overall, the median duration of antimicrobial prophylaxis was 36 hours (range 8 to 96 hr). CONCLUSIONS: Despite the availability of various published guidelines, our survey identified several areas for improvement with respect to antimicrobial prophylaxis in adult cardiac surgery across Canada. PMID:18159370
Code of Federal Regulations, 2010 CFR
2010-04-01
... TOBACCO Operations by Manufacturers of Tobacco Products Inventories and Reports § 40.202 Reports. (a... shall be made regardless of whether any operations or transactions occurred during the month or portion...) Manufactured, (2) Received in bond, (3) Received by return to bond, (4) Disclosed by inventory as an overage...
A broadband THz receiver for low background space applications
NASA Technical Reports Server (NTRS)
Hagmann, C.; Benford, D. J.; Clapp, A. C.; Richards, P. L.; Timbie, P.
1992-01-01
We have developed a sensitive bolometric receiver for low background space applications. In a 10 percent bandwidth at 1 THz, this receiver is approximately 100 times more sensitive than a quantum limited heterodyne receiver with a 1 GHz IF bandwidth. This receiver is designed to be used for the long wavelength band (200-700 microns) in the MIPS instrument on NASA's SIRTF satellite. The bolometers are cooled to 100 mK by an adiabatic demagnetization refrigerator. Roughly 60 g of cesium chrome alum salt is partially demagnetized to 100 mK, followed by a slow regulated downramp to compensate for the heat leak. The hold time of the ADR system is about 18 hours with a temperature stability of delta T(sub rms) approx. equals 10 micro-K. The composite bolometers have electrical responsivities of 10(exp 9)V/W and electrical NEP's of about 3x10(exp -17) W/square root of Hz. The bolometer signals are read out by JFET preamplifiers located on the helium plate and operated at 120 K. We have addressed a number of space qualification issues, such as the development of an analog magnet controller, construction of a cryogenic shake-table for bolometers and selection of the paramagnetic salt CCA which can survive a bakeout at 50 C. The receiver is scheduled to be flown in the spring of 1992 on a balloon telescope. This flight has a dual purpose. One is to provide realistic test of the capabilities of the new receiver. The other is to search for anisotropies in the cosmic microwave background on scales of a few degrees.
Jani, Meghna; Chinoy, Hector; Warren, Richard B; Griffiths, Christopher E M; Plant, Darren; Fu, Bo; Morgan, Ann W; Wilson, Anthony G; Isaacs, John D; Hyrich, KimmeL; Barton, Anne
2015-05-01
To investigate whether antidrug antibodies and/or drug non-trough levels predict the long-term treatment response in a large cohort of patients with rheumatoid arthritis (RA) treated with adalimumab or etanercept and to identify factors influencing antidrug antibody and drug levels to optimize future treatment decisions. A total of 331 patients from an observational prospective cohort were selected (160 patients treated with adalimumab and 171 treated with etanercept). Antidrug antibody levels were measured by radioimmunoassay, and drug levels were measured by enzyme-linked immunosorbent assay in 835 serial serum samples obtained 3, 6, and 12 months after initiation of therapy. The association between antidrug antibodies and drug non-trough levels and the treatment response (change in the Disease Activity Score in 28 joints) was evaluated. Among patients who completed 12 months of followup, antidrug antibodies were detected in 24.8% of those receiving adalimumab (31 of 125) and in none of those receiving etanercept. At 3 months, antidrug antibody formation and low adalimumab levels were significant predictors of no response according to the European League Against Rheumatism (EULAR) criteria at 12 months (area under the receiver operating characteristic curve 0.71 [95% confidence interval (95% CI) 0.57, 0.85]). Antidrug antibody-positive patients received lower median dosages of methotrexate compared with antidrug antibody-negative patients (15 mg/week versus 20 mg/week; P = 0.01) and had a longer disease duration (14.0 versus 7.7 years; P = 0.03). The adalimumab level was the best predictor of change in the DAS28 at 12 months, after adjustment for confounders (regression coefficient 0.060 [95% CI 0.015, 0.10], P = 0.009). Etanercept levels were associated with the EULAR response at 12 months (regression coefficient 0.088 [95% CI 0.019, 0.16], P = 0.012); however, this difference was not significant after adjustment. A body mass index of ≥30 kg/m(2) and poor adherence were associated with lower drug levels. Pharmacologic testing in anti-tumor necrosis factor-treated patients is clinically useful even in the absence of trough levels. At 3 months, antidrug antibodies and low adalimumab levels are significant predictors of no response according to the EULAR criteria at 12 months. © 2015 The Authors. Arthritis & Rheumatology is published by Wiley Periodicals, Inc. on behalf of the American College of Rheumatology.
NASA Astrophysics Data System (ADS)
Virgen, Matthew Miguel
Two significant goals in solar plant operation are lower cost and higher efficiencies. To achieve those goals, a combined cycle gas turbine (CCGT) system, which uses the hot gas turbine exhaust to produce superheated steam for a bottoming Rankine cycle by way of a heat recovery steam generator (HRSG), is investigated in this work. Building off of a previous gas turbine model created at the Combustion and Solar Energy Laboratory at SDSU, here are added the HRSG and steam turbine model, which had to handle significant change in the mass flow and temperature of air exiting the gas turbine due to varying solar input. A wide range of cases were run to explore options for maximizing both power and efficiency from the proposed CSP CCGT plant. Variable guide vanes (VGVs) were found in the earlier model to be an effective tool in providing operational flexibility to address the variable nature of solar input. Combined cycle efficiencies in the range of 50% were found to result from this plant configuration. However, a combustor inlet temperature (CIT) limit leads to two distinct Modes of operation, with a sharp drop in both plant efficiency and power occurring when the air flow through the receiver exceeded the CIT limit. This drawback can be partially addressed through strategic use of the VGVs. Since system response is fully established for the relevant range of solar input and variable guide vane angles, the System Advisor Model (SAM) from NREL can be used to find what the actual expected solar input would be over the course of the day, and plan accordingly. While the SAM software is not yet equipped to model a Brayton cycle cavity receiver, appropriate approximations were made in order to produce a suitable heliostat field to fit this system. Since the SPHER uses carbon nano-particles as the solar absorbers, questions of particle longevity and how the particles might affect the flame behavior in the combustor were addressed using the chemical kinetics software ChemkinPro by modeling the combustion characteristics both with and without the particles. This work is presented in the Appendix.
Josso, Nicolas F; Ioana, Cornel; Mars, Jérôme I; Gervaise, Cédric
2010-12-01
Acoustic channel properties in a shallow water environment with moving source and receiver are difficult to investigate. In fact, when the source-receiver relative position changes, the underwater environment causes multipath and Doppler scale changes on the transmitted signal over low-to-medium frequencies (300 Hz-20 kHz). This is the result of a combination of multiple paths propagation, source and receiver motions, as well as sea surface motion or water column fast changes. This paper investigates underwater acoustic channel properties in a shallow water (up to 150 m depth) and moving source-receiver conditions using extracted time-scale features of the propagation channel model for low-to-medium frequencies. An average impulse response of one transmission is estimated using the physical characteristics of propagation and the wideband ambiguity plane. Since a different Doppler scale should be considered for each propagating signal, a time-warping filtering method is proposed to estimate the channel time delay and Doppler scale attributes for each propagating path. The proposed method enables the estimation of motion-compensated impulse responses, where different Doppler scaling factors are considered for the different time delays. It was validated for channel profiles using real data from the BASE'07 experiment conducted by the North Atlantic Treaty Organization Undersea Research Center in the shallow water environment of the Malta Plateau, South Sicily. This paper provides a contribution to many field applications including passive ocean tomography with unknown natural sources position and movement. Another example is active ocean tomography where sources motion enables to rapidly cover one operational area for rapid environmental assessment and hydrophones may be drifting in order to avoid additional flow noise.
Cieslak, Kasia P; Huisman, Floor; Bais, Thomas; Bennink, Roelof J; van Lienden, Krijn P; Verheij, Joanne; Besselink, Marc G; Busch, Olivier R C; van Gulik, Thomas M
2017-07-01
Preoperative portal vein embolization is widely used to increase the future remnant liver. Identification of nonresponders to portal vein embolization is essential because these patients may benefit from associating liver partition and portal vein ligation for staged hepatectomy (ALPPS), which induces a more powerful hypertrophy response. 99m Tc-mebrofenin hepatobiliary scintigraphy is a quantitative method for assessment of future remnant liver function with a calculated cutoff value for the prediction of postoperative liver failure. The aim of this study was to analyze future remnant liver function before portal vein embolization to predict sufficient functional hypertrophy response after portal vein embolization. Sixty-three patients who underwent preoperative portal vein embolization and computed tomography imaging were included. Hepatobiliary scintigraphy was performed to determine pre-portal vein embolization and post-portal vein embolization future remnant liver function. Receiver operator characteristic analysis of pre-portal vein embolization future remnant liver function was performed to identify patients who would meet the post-portal vein embolization cutoff value for sufficient function (ie, 2.7%/min/m 2 ). Mean pre-portal vein embolization future remnant liver function was 1.80% ± 0.45%/min/m 2 and increased to 2.89% ± 0.97%/min/m 2 post-portal vein embolization. Receiver operator characteristic analysis in 33 patients who did not receive chemotherapy revealed that a pre-portal vein embolization future remnant liver function of ≥1.72%/min/m 2 was able to identify patients who would meet the safe future remnant liver function cutoff value 3 weeks after portal vein embolization (area under the curve = 0.820). The predictive value was less pronounced in 30 patients treated with neoadjuvant chemotherapy (area under the curve = 0.618). A total of 45 of 63 patients underwent liver resection, of whom 5 of 45 developed postoperative liver failure; 4 of 5 patients had a post-portal vein embolization future remnant liver function below the cutoff value for safe resection. When selecting patients for portal vein embolization, future remnant liver function assessed with hepatobiliary scintigraphy can be used as a predictor of insufficient functional hypertrophy after portal vein embolization, especially in nonchemotherapy patients. These patients are potential candidates for ALPPS. Copyright © 2017 Elsevier Inc. All rights reserved.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false What responsibilities does the Federal Aviation Administration (FAA) have after receiving a copy of the notice (and a copy of... responsibilities does the Federal Aviation Administration (FAA) have after receiving a copy of the notice (and a...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false What responsibilities does the Federal Aviation Administration (FAA) have after receiving a copy of the notice (and a copy of... responsibilities does the Federal Aviation Administration (FAA) have after receiving a copy of the notice (and a...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false What responsibilities does the Federal Aviation Administration (FAA) have after receiving a copy of the notice (and a copy of... responsibilities does the Federal Aviation Administration (FAA) have after receiving a copy of the notice (and a...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false What responsibilities does the Federal Aviation Administration (FAA) have after receiving a copy of the notice (and a copy of... responsibilities does the Federal Aviation Administration (FAA) have after receiving a copy of the notice (and a...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What are the receiving agency's responsibilities in the transfer or donation of aircraft parts? 102-33.335 Section 102-33.335... agency's responsibilities in the transfer or donation of aircraft parts? An agency that receives...
Code of Federal Regulations, 2012 CFR
2012-01-01
... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false What are the receiving agency's responsibilities in the transfer or donation of aircraft parts? 102-33.335 Section 102-33.335... agency's responsibilities in the transfer or donation of aircraft parts? An agency that receives...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false What are the receiving agency's responsibilities in the transfer or donation of aircraft parts? 102-33.335 Section 102-33.335... agency's responsibilities in the transfer or donation of aircraft parts? An agency that receives...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false What are the receiving agency's responsibilities in the transfer or donation of aircraft parts? 102-33.335 Section 102-33.335... agency's responsibilities in the transfer or donation of aircraft parts? An agency that receives...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false What are the receiving agency's responsibilities in the transfer or donation of aircraft parts? 102-33.335 Section 102-33.335... agency's responsibilities in the transfer or donation of aircraft parts? An agency that receives...
Development of an Ultra-Wideband Receiver for the North America Array
NASA Astrophysics Data System (ADS)
Velazco, J. E.; Soriano, M.; Hoppe, D.; Russell, D.; D'Addario, L.; Long, E.; Bowen, J.; Samoska, L.; Lazio, J.
2016-11-01
The North America Array (NAA) is a concept for a radio astronomical interferometric array operating in the 1.2 GHz to 116 GHz frequency range. It has been designed to provide substantial improvements in sensitivity, angular resolution, and frequency coverage beyond the current Karl G. Jansky Very Large Array (VLA). It will have a continuous frequency coverage of 1.2 GHz to 50 GHz and 70 to 116 GHz, and a total aperture 10 times more sensitive than the VLA (and 25 times more sensitive than a 34-m-diameter antenna of the Deep Space Network [DSN]). One of the key goals for the NAA is to reduce the operating costs without sacrificing performance. We are designing an ultra-wideband receiver package designed to operate across the 8 to 48 GHz frequency range in contrast to the current VLA, which covers this frequency range with five receiver packages. Reducing the number of receiving systems required to cover the full frequency range would reduce operating costs. To minimize implementation, operational, and maintenance costs, we are developing a receiver that is compact, simple to assemble, and that consumes less power. The objective of this work is to develop a prototype integrated feed-receiver package with a sensitivity performance comparable to current narrower-band systems on radio telescopes and the DSN, but with a design that meets the requirement of low long-term operational costs. The ultra-wideband receiver package consists of a feedhorn, low-noise amplifier (LNA), and downconverters to analog intermediate frequencies. Both the feedhorn and the LNA are cryogenically cooled. Key features of this design are a quad-ridge feedhorn with dielectric loading and a cryogenic receiver with a noise temperature of no more than 30°K at the low end of the band. In this article, we report on the status of this receiver package development, including the feed design and LNA implementation. We present simulation studies of the feed horn carried out to optimize illumination efficiencies across the band of interest. In addition, we show experimental results of low-noise 70-nm gallium arsenide, metamorphic high-electron-mobility-transistor (HEMT) amplifier testing performed across the 1 to 18 GHz frequency range. Also presented are 8 to 48 GHz simulation results for 35-nm indium phosphide HEMT amplifiers.
The Army Meter Data Management System (MDMS): A Case Study for Army MDMS Pilot
2011-05-11
Academy (West Point, NY) • Meets DoD cyber-security requirements – Received Authority to Operate from Army NETCOM effective 23 April 2010 – Received...to Operate on DoD network – Received ATO from Army NETCOM effective 23 April 2010 – Received CoN from Army NETCOM on 26 July 2010 • Over 195 meters...SCH~ From I Aug 2010001D To 8 Aug 2010 00 00 En•l’iY f*ttk COnWtnptlon J96S9U81’ WII FillCilftl .. Totol , ......... ~ Metert - Met el\\ r;’l
A Brayton cycle solar dynamic heat receiver for space
NASA Technical Reports Server (NTRS)
Sedgwick, L. M.; Nordwall, H. L.; Kaufmann, K. J.; Johnson, S. D.
1989-01-01
The detailed design of a heat receiver developed to meet the requirements of the Space Station Freedom, which will be assembled and operated in low earth orbit beginning in the mid-1990's, is described. The heat receiver supplies thermal energy to a nominal 25-kW closed-Brayton-cycle power conversion unit. The receiver employs an integral thermal energy storage system utilizing the latent heat of a eutectic-salt phase-change mixture to store energy for eclipse operation. The salt is contained within a felt metal matrix which enhances heat transfer and controls the salt void distribution during solidification.
Remedial investigation/feasibility study report for Lower Watts Bar Reservoir Operable Unit
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-03-01
This document is the combined Remedial Investigation and Feasibility Study Report for the lower Watts Bar Reservoir (LWBR) Operable Unit (OU). The LWBR is located in Roane, Rhea, and Meigs counties, Tennessee, and consists of Watts Bar Reservoir downstream of the Clinch river. This area has received hazardous substances released over a period of 50 years from the US Department of Energy`s Oak Ridge Reservation (ORR), a National Priority List site established under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). As required by this law, the ORR and all off-site areas that have received contaminants, including LWBR, mustmore » be investigated to determine the risk to human health and the environment resulting from these releases, the need for any remedial action to reduce these risks, and the remedial actions that are most feasible for implementation in this OU. Contaminants from the ORR are primarily transported to the LWBR via the Clinch River. There is little data regarding the quantities of most contaminants potentially released from the ORR to the Clinch River, particularly for the early years of ORR operations. Estimates of the quantities released during this period are available for most radionuclides and some inorganic contaminants, indicating that releases 30 to 50 years ago were much higher than today. Since the early 1970s, the release of potential contaminants has been monitored for compliance with environmental law and reported in the annual environmental monitoring reports for the ORR.« less
NASA Technical Reports Server (NTRS)
OFarrell, Zachary L.
2013-01-01
The goal of this project is to create a website that displays video, countdown clock, and event times to customers during launches, without needing to be connected to the internal operations network. The requirements of this project are to also minimize the delay in the clock and events to be less than two seconds. The two parts of this are the webpage, which will display the data and videos to the user, and a server to send clock and event data to the webpage. The webpage is written in HTML with CSS and JavaScript. The JavaScript is responsible for connecting to the server, receiving new clock data, and updating the webpage. JavaScript is used for this because it can send custom HTTP requests from the webpage, and provides the ability to update parts of the webpage without having to refresh the entire page. The server application will act as a relay between the operations network, and the open internet. On the operations network side, the application receives multicast packets that contain countdown clock and events data. It will then parse the data into current countdown times and events, and create a packet with that information that can be sent to webpages. The other part will accept HTTP requests from the webpage, and respond to them with current data. The server is written in C# with some C++ files used to define the structure of data packets. The videos for the webpage will be shown in an embedded player from UStream.
Paratesticular Liposarcoma; a Case Report
Omidvari, Shapour; Hamedi, Seyyed Hasan; Moaddab-Shoar, Leila; Nasrollahi, Hamid; Daneshbod, Yahya; Mosleh-Shirazi, Mohammad Amin; Ansrai, Mansour; Mohammadianpanah, Mohammad; Ahmadloo, Niloofar; Mosalaei, Ahmad
2014-01-01
Paratesticular sarcomas have happened rarely. Due to the infrequency of this malignant disease and its diverse histopathologic subtypes, no standard treatment would be available. Multiple treatments have reported in literature with different results. We have reported a 55 years old man with a 30 years history of paratesticular mass. After multiple operations, radical orchiectomy has revealed liposarcoma. The patient has been receiving 50 Gy radiation to the scrotum and inguinal area. After 18 months follow up, the patient was well and disease free. He has shown good response to surgery and radiotherapy, so we have reported the disease and its clinical course. PMID:25628845
Paratesticular liposarcoma; a case report.
Omidvari, Shapour; Hamedi, Seyyed Hasan; Moaddab-Shoar, Leila; Nasrollahi, Hamid; Daneshbod, Yahya; Mosleh-Shirazi, Mohammad Amin; Ansrai, Mansour; Mohammadianpanah, Mohammad; Ahmadloo, Niloofar; Mosalaei, Ahmad
2014-01-01
Paratesticular sarcomas have happened rarely. Due to the infrequency of this malignant disease and its diverse histopathologic subtypes, no standard treatment would be available. Multiple treatments have reported in literature with different results. We have reported a 55 years old man with a 30 years history of paratesticular mass. After multiple operations, radical orchiectomy has revealed liposarcoma. The patient has been receiving 50 Gy radiation to the scrotum and inguinal area. After 18 months follow up, the patient was well and disease free. He has shown good response to surgery and radiotherapy, so we have reported the disease and its clinical course.
Proximal caries detection: Sirona Sidexis versus Kodak Ektaspeed Plus.
Khan, Emad A; Tyndall, Donald A; Ludlow, John B; Caplan, Daniel
2005-01-01
This study compared the accuracy of intraoral film and a charge-coupled device (CCD) receptor for proximal caries detection. Four observers evaluated images of the proximal surfaces of 40 extracted posterior teeth. The presence or absence of caries was scored using a five-point confidence scale. The actual status of each surface was determined from ground section histology. Responses were evaluated by means of receiver operating characteristic (ROC) analysis. Areas under ROC curves (Az) were assessed through a paired t-test. The performance of the CCD-based intraoral sensor was not different statistically from Ektaspeed Plus film in detecting proximal caries.
Ferdinand von Mueller's interactions with Charles Darwin and his response to Darwinism.
Lucas, A M
2010-01-01
Although Ferdinand Mueller (later von Mueller), Government Botanist of Victoria, opposed Darwin's theories when "On the origin of species" was published, there has been little detailed study of the nature of Mueller's opposition from 1860, when he received a presentation copy of "Origin," to his death in 1896. Analysis of Mueller's correspondence and publications shows that he remained a theist and misunderstood key aspects of Darwin's theory. However, Mueller did come to accept that natural selection could operate within a species, although never accepting it could produce speciation. Despite these differences he retained a cordial relationship with Darwin.
Network acceleration techniques
NASA Technical Reports Server (NTRS)
Crowley, Patricia (Inventor); Maccabe, Arthur Barney (Inventor); Awrach, James Michael (Inventor)
2012-01-01
Splintered offloading techniques with receive batch processing are described for network acceleration. Such techniques offload specific functionality to a NIC while maintaining the bulk of the protocol processing in the host operating system ("OS"). The resulting protocol implementation allows the application to bypass the protocol processing of the received data. Such can be accomplished this by moving data from the NIC directly to the application through direct memory access ("DMA") and batch processing the receive headers in the host OS when the host OS is interrupted to perform other work. Batch processing receive headers allows the data path to be separated from the control path. Unlike operating system bypass, however, the operating system still fully manages the network resource and has relevant feedback about traffic and flows. Embodiments of the present disclosure can therefore address the challenges of networks with extreme bandwidth delay products (BWDP).
Zador, Zsolt; Sperrin, Matthew; King, Andrew T
2016-01-01
Traumatic brain injury remains a global health problem. Understanding the relative importance of outcome predictors helps optimize our treatment strategies by informing assessment protocols, clinical decisions and trial designs. In this study we establish importance ranking for outcome predictors based on receiver operating indices to identify key predictors of outcome and create simple predictive models. We then explore the associations between key outcome predictors using Bayesian networks to gain further insight into predictor importance. We analyzed the corticosteroid randomization after significant head injury (CRASH) trial database of 10008 patients and included patients for whom demographics, injury characteristics, computer tomography (CT) findings and Glasgow Outcome Scale (GCS) were recorded (total of 13 predictors, which would be available to clinicians within a few hours following the injury in 6945 patients). Predictions of clinical outcome (death or severe disability at 6 months) were performed using logistic regression models with 5-fold cross validation. Predictive performance was measured using standardized partial area (pAUC) under the receiver operating curve (ROC) and we used Delong test for comparisons. Variable importance ranking was based on pAUC targeted at specificity (pAUCSP) and sensitivity (pAUCSE) intervals of 90-100%. Probabilistic associations were depicted using Bayesian networks. Complete AUC analysis showed very good predictive power (AUC = 0.8237, 95% CI: 0.8138-0.8336) for the complete model. Specificity focused importance ranking highlighted age, pupillary, motor responses, obliteration of basal cisterns/3rd ventricle and midline shift. Interestingly when targeting model sensitivity, the highest-ranking variables were age, severe extracranial injury, verbal response, hematoma on CT and motor response. Simplified models, which included only these key predictors, had similar performance (pAUCSP = 0.6523, 95% CI: 0.6402-0.6641 and pAUCSE = 0.6332, 95% CI: 0.62-0.6477) compared to the complete models (pAUCSP = 0.6664, 95% CI: 0.6543-0.679, pAUCSE = 0.6436, 95% CI: 0.6289-0.6585, de Long p value 0.1165 and 0.3448 respectively). Bayesian networks showed the predictors that did not feature in the simplified models were associated with those that did. We demonstrate that importance based variable selection allows simplified predictive models to be created while maintaining prediction accuracy. Variable selection targeting specificity confirmed key components of clinical assessment in TBI whereas sensitivity based ranking suggested extracranial injury as one of the important predictors. These results help refine our approach to head injury assessment, decision-making and outcome prediction targeted at model sensitivity and specificity. Bayesian networks proved to be a comprehensive tool for depicting probabilistic associations for key predictors giving insight into why the simplified model has maintained accuracy.
ERIC Educational Resources Information Center
Wang, Qiu; Diemer, Matthew A.; Maier, Kimberly S.
2013-01-01
This study integrated Bayesian hierarchical modeling and receiver operating characteristic analysis (BROCA) to evaluate how interest strength (IS) and interest differentiation (ID) predicted low–socioeconomic status (SES) youth's interest-major congruence (IMC). Using large-scale Kuder Career Search online-assessment data, this study fit three…
26 CFR 1.132-7 - Employer-operated eating facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Employer-operated eating facilities. (a) In general—(1) Condition for exclusion—(i) General rule. The value... determine the number of meals received by volunteers who receive food and beverages at a hospital, free or... volunteers. If an employer charges nonemployees a greater amount than employees, in determining whether the...
26 CFR 1.132-7 - Employer-operated eating facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Employer-operated eating facilities. (a) In general—(1) Condition for exclusion—(i) General rule. The value... determine the number of meals received by volunteers who receive food and beverages at a hospital, free or... volunteers. If an employer charges nonemployees a greater amount than employees, in determining whether the...
26 CFR 1.132-7 - Employer-operated eating facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Employer-operated eating facilities. (a) In general—(1) Condition for exclusion—(i) General rule. The value... determine the number of meals received by volunteers who receive food and beverages at a hospital, free or... volunteers. If an employer charges nonemployees a greater amount than employees, in determining whether the...
47 CFR 13.201 - Qualifying for a commercial operator license or endorsement.
Code of Federal Regulations, 2012 CFR
2012-10-01
... satisfactory knowledge of FCC rules and must have the ability to send correctly and receive correctly spoken...) Applicant must have one year of experience in sending and receiving public correspondence by radiotelegraph at a public coast station, a ship station, or both. (2) Second Class Radiotelegraph Operator's...
47 CFR 13.201 - Qualifying for a commercial operator license or endorsement.
Code of Federal Regulations, 2011 CFR
2011-10-01
... satisfactory knowledge of FCC rules and must have the ability to send correctly and receive correctly spoken...) Applicant must have one year of experience in sending and receiving public correspondence by radiotelegraph at a public coast station, a ship station, or both. (2) Second Class Radiotelegraph Operator's...
Risk is not our business: safety of thoracic surgery in patients using antiplatelet therapy.
Bertolaccini, Luca; Terzi, Alberto; Rizzardi, Giovanna; Gorla, Alberto; Viti, Andrea; Palmisano, Sarah; Coletta, Giuseppe
2012-02-01
American Heart Association recommendations have changed preoperative management of patients with antiplatelet therapy (APT). We assessed safety and outcomes of surgery in patients who were receiving APT. A prospective study of patients operated on while receiving APT was matched with those with no APT (ratio 1:4), using the propensity score method. Logistic regression analysis was used to identify covariates among imbalanced baseline patient variables. Both χ(2) test and Fisher's test were used to calculate the probability value for the comparison of dichotomous variables. Between January 2008 and December 2010, 38 patients who received APT at the time of surgery were matched with 141 patients who had not received APT. APT indications were a history of myocardial infarction, coronary artery by-pass graft and/or valve replacement (19), coronary artery stent (11) and severe peripheral vascular disease (8). None of the patients required re-operation for bleeding. Two patients received blood transfusions. The amount of chest tube drainage was not statistically significantly different. There were no statistically significant differences between the outcomes for the operative time, length of hospital stay, estimated blood loss or morbidity. The results show that thoracic surgical procedures can safely be performed in patients receiving APT at the time of surgery, with no increased risk of bleeding or morbidity and no differences in the operative time and the length of hospital stay.
Kuo, Pao-Jen; Wu, Shao-Chun; Chien, Peng-Chen; Chang, Shu-Shya; Rau, Cheng-Shyuan; Tai, Hsueh-Ling; Peng, Shu-Hui; Lin, Yi-Chun; Chen, Yi-Chun; Hsieh, Hsiao-Yun; Hsieh, Ching-Hua
2018-01-01
Background The aim of this study was to develop an effective surgical site infection (SSI) prediction model in patients receiving free-flap reconstruction after surgery for head and neck cancer using artificial neural network (ANN), and to compare its predictive power with that of conventional logistic regression (LR). Materials and methods There were 1,836 patients with 1,854 free-flap reconstructions and 438 postoperative SSIs in the dataset for analysis. They were randomly assigned tin ratio of 7:3 into a training set and a test set. Based on comprehensive characteristics of patients and diseases in the absence or presence of operative data, prediction of SSI was performed at two time points (pre-operatively and post-operatively) with a feed-forward ANN and the LR models. In addition to the calculated accuracy, sensitivity, and specificity, the predictive performance of ANN and LR were assessed based on area under the curve (AUC) measures of receiver operator characteristic curves and Brier score. Results ANN had a significantly higher AUC (0.892) of post-operative prediction and AUC (0.808) of pre-operative prediction than LR (both P<0.0001). In addition, there was significant higher AUC of post-operative prediction than pre-operative prediction by ANN (p<0.0001). With the highest AUC and the lowest Brier score (0.090), the post-operative prediction by ANN had the highest overall predictive performance. Conclusion The post-operative prediction by ANN had the highest overall performance in predicting SSI after free-flap reconstruction in patients receiving surgery for head and neck cancer. PMID:29568393
Powertrain with powersplit pump input and method of use thereof
Johnson, Kris W.; Rose, Charles E.
2009-04-28
A powertrain includes an engine operatively connected to a primary power consuming device to transmit power thereto. The powertrain also includes a motor and a pump. The power output of the motor is independent of the power output of the engine. An epicyclic geartrain includes first, second and third members. The first member is operatively connected to the engine to receive power therefrom. The second member is operatively connected to the motor to receive power therefrom. The third member is operatively connected to the pump to transmit power thereto.
Postoperative nausea and vomiting (PONV) in outpatient repair of inguinal hernia.
Palumbo, Piergaspare; Usai, Sofia; Amatucci, Chiara; Pulli, Valentina Taurisano; Illuminati, Giulio; Vietri, Francesco; Tellan, Guglielmo
2018-01-01
Nausea and vomiting are among the most frequent complications following anesthesia and surgery. Due to anesthesia seems to be primarily responsible for post operative nausea and vomiting (PONV) in Day Surgery facilities, the aim of the study is to evaluate how different methods of anesthesia could modify the onset of postoperative nausea and vomiting in a population of patients undergoing inguinal hernia repair. Ninehundredten patients, aged between 18 and 87 years, underwent open inguinal hernia repair. The PONV risk has been assessed according to Apfel Score. Local anesthetic infiltration, performed by the surgeon in any cases, has been supported by and analgo-sedation with Remifentanil in 740 patients; Fentanyl was used in 96 cases and the last 74 underwent deep sedation with Propofol . Among the 910 patients who underwent inguinal hernia repair, PONV occurred in 68 patients (7.5%). Among patients presenting PONV, 29 received Remifentanil, whereas 39 received Fentanyl. In the group of patients receiving Propofol, no one presented PONV. This difference is statistically significant (p < .01). Moreover, only 50 patients of the total sample received antiemetic prophylaxis, and amongst these, PONV occurred in 3 subjects. Compared to Remifentanil, Fentanyl has a major influence in causing PONV. Nonetheless, an appropriate antiemetic prophylaxis can significantly reduce this undesirable complication. Key words: Day Surgery, Fentanyl, Inguinal, Hernia repair, Nausea, Vomiting.
Structural positioning of nurse leaders and empowerment.
Hughes, Kerri-Ann; Carryer, Jennifer Barbara; White, Jill
2015-08-01
To analyse the reporting structures of nursing leaders of publicly funded hospitals and seek both the views of nurse leaders and Chief Executive Officers/Chief Operating Officers on the structural positioning of nurse leaders in the organisation. Concern that the continuing restructuring within hospital structures and focus on economic outputs in health services is diminishing the value of nursing leadership. Qualitative surveys with Nursing leaders and Chief Executive Officers of public hospitals. Seventeen Directors of Nursing and 10 Chief Executive Officer/Chief Operating Officers' responses were received using two semi-structured questionnaires. Themes were developed from data coded and analysed by hand. Four broad themes emerged from analysis of the data: (1) variable positional reporting between Director of Nursing and Chief Executive Officers occurred; (2) variable levels of inclusion and influence at the executive decision-making level; (3) ambiguous financial responsibilities and accountabilities held by Director of Nursing; and (4) blurred lines existed between operational and professional reporting lines. Findings unique to the research indicate that the varying levels of visibility and inclusion impact on the structural positioning of nurse leaders which influences authority and empowerment. Responses from the data analysis indicate that the structural power of nurse leaders defined by the factors of opportunity, power and proportion were hindered by dual accountability reporting lines and a lack of financial control. The structural positioning of nurse leaders is vital to ensure that they are empowered and able to meet the adaptations required in a changing environment that supports the delivery of effective, quality healthcare. © 2015 John Wiley & Sons Ltd.
Grolla, Allen; Jones, Steven M.; Fernando, Lisa; Strong, James E.; Ströher, Ute; Möller, Peggy; Paweska, Janusz T.; Burt, Felicity; Pablo Palma, Pedro; Sprecher, Armand; Formenty, Pierre; Roth, Cathy; Feldmann, Heinz
2011-01-01
Background Marburg virus (MARV), a zoonotic pathogen causing severe hemorrhagic fever in man, has emerged in Angola resulting in the largest outbreak of Marburg hemorrhagic fever (MHF) with the highest case fatality rate to date. Methodology/Principal Findings A mobile laboratory unit (MLU) was deployed as part of the World Health Organization outbreak response. Utilizing quantitative real-time PCR assays, this laboratory provided specific MARV diagnostics in Uige, the epicentre of the outbreak. The MLU operated over a period of 88 days and tested 620 specimens from 388 individuals. Specimens included mainly oral swabs and EDTA blood. Following establishing on site, the MLU operation allowed a diagnostic response in <4 hours from sample receiving. Most cases were found among females in the child-bearing age and in children less than five years of age. The outbreak had a high number of paediatric cases and breastfeeding may have been a factor in MARV transmission as indicated by the epidemiology and MARV positive breast milk specimens. Oral swabs were a useful alternative specimen source to whole blood/serum allowing testing of patients in circumstances of resistance to invasive procedures but limited diagnostic testing to molecular approaches. There was a high concordance in test results between the MLU and the reference laboratory in Luanda operated by the US Centers for Disease Control and Prevention. Conclusions/Significance The MLU was an important outbreak response asset providing support in patient management and epidemiological surveillance. Field laboratory capacity should be expanded and made an essential part of any future outbreak investigation. PMID:21629730
Pernar, Luise I M; Ashley, Stanley W; Smink, Douglas S; Zinner, Michael J; Peyre, Sarah E
2012-01-01
Practicing within the Halstedian model of surgical education, academic surgeons serve dual roles as physicians to their patients and educators of their trainees. Despite this significant responsibility, few surgeons receive formal training in educational theory to inform their practice. The goal of this work was to gain an understanding of how master surgeons approach teaching uncommon and highly complex operations and to determine the educational constructs that frame their teaching philosophies and approaches. Individuals included in the study were queried using electronically distributed open-ended, structured surveys. Responses to the surveys were analyzed and grouped using grounded theory and were examined for parallels to concepts of learning theory. Academic teaching hospital. Twenty-two individuals identified as master surgeons. Twenty-one (95.5%) individuals responded to the survey. Two primary thematic clusters were identified: global approach to teaching (90.5% of respondents) and approach to intraoperative teaching (76.2%). Many of the emergent themes paralleled principles of transfer learning theory outlined in the psychology and education literature. Key elements included: conferring graduated responsibility (57.1%), encouraging development of a mental set (47.6%), fostering or expecting deliberate practice (42.9%), deconstructing complex tasks (38.1%), vertical transfer of information (33.3%), and identifying general principles to structure knowledge (9.5%). Master surgeons employ many of the principles of learning theory when teaching uncommon and highly complex operations. The findings may hold significant implications for faculty development in surgical education. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
Dilmen, Ozlem Korkmaz; Yentur, Ercument; Tunali, Yusuf; Balci, Huriye; Bahar, Mois
2017-02-01
Surgical trauma produces metabolic and hormonal responses, which are characterized by insulin resistance. Due to extension of the preoperative fasting period, which increases the magnitude of postoperative insulin resistance, preoperative oral carbohydrates (POC) have been developed. This prospective, randomized, controlled study was performed on 43 ASA I-II patients undergoing elective microsurgical lumbar discectomy. The intervention group received oral carbohydrate solution 800mL the night before and 400mL 2h prior to operation. The other group fasted for 8h prior to operation. Blood samples were obtained the day before the operation, before induction of anesthesia, after skin incision, 1h, 2h, 6h and 24h following skin incision. Blood glucose, plasma insulin, cortisol and interleukin-6 (IL-6) levels were determined. The primary endpoint was to assess the effect of POC treatment on insulin resistance and surgical stress response following lumbar disc surgery. The secondary endpoint was to assess POC's effects on postoperative nausea and vomiting. The serum insulin levels were higher before induction of anesthesia in the study group and returned to fasted group levels by 2h after skin incision. The plasma IL-6 levels were higher in the intervention group at 6h after the skin incision. There were no differences between the two groups with respect to blood glucose, plasma cortisol levels and the incidence of nausea and vomiting. This study suggests that use of POC treatment does not attenuate development of insulin resistance in patients undergoing lumbar disc surgery. Copyright © 2016. Published by Elsevier B.V.
NASA Technical Reports Server (NTRS)
Pritchett, Amy R.; Hansman, R. John
1994-01-01
Current Air Traffic Control communications use shared very high frequency (VHF) voice frequencies from which pilots can obtain 'Party Line' Information (PLI) by overhearing communications addressed to other aircraft. A prior study has shown pilots perceive this PLI to be important. There is concern that some critical PLI may be lost in the proposed datalink environment where communications will be discretely addressed. Different types of flight operations will be, equipped with datalink equipment at different times, generating a 'mixed environment' where some pilots may rely on PLI while others will receive their information by datalink. To research the importance, availability and accuracy of PLI and to query pilots on the information they feel is necessary, a survey was distributed to pilots. The pilots were selected from four flight operation groups to study the variations in PLI requirements in the mixed datalink environment. Pilots perceived PLI to be important overall. Specific information elements pertaining to traffic and weather information were identified as Critical. Most PLI elements followed a pattern of higher perceived importance during terminal area operations, final approach and landing. Pilots from the different flight operation groups identified some elements as particularly important. Pilots perceived PLI to be only moderately available and accurate overall. Several PLI elements received very low availability and accuracy ratings but are perceived as important. In a free response question designed to find the information requirements for global situation awareness, pilots frequently indicated a need for traffic and weather information. These elements were also frequently cited by them as information that could be presented by a datalink system. The results of this survey identify specific concerns to be addressed when implementing datalink communications.
Weather satellite picture receiving stations, APT digital scan converter
NASA Technical Reports Server (NTRS)
Vermillion, C. H.; Kamowski, J. C.
1975-01-01
The automatic picture transmission digital scan converter is used at ground stations to convert signals received from scanning radiometers to data compatible with ground equipment designed to receive signals from vidicons aboard operational meteorological satellites. Information necessary to understand the circuit theory, functional operation, general construction and calibration of the converter is provided. Brief and detailed descriptions of each of the individual circuits are included, accompanied by a schematic diagram contained at the end of each circuit description. Listings of integral parts and testing equipment required as well as an overall wiring diagram are included. This unit will enable the user to readily accept and process weather photographs from the operational meteorological satellites.
Bushnell, M C; Weiss, S J
1977-03-01
In Experiments I and II, rats were trained to respond on one lever during light and another during tone. The absence of tone and light controlled response cessation. In the multiple schedule of Experiment I, all reinforcements were received for responding in tone or light; in the chain schedule of Experiment II, all reinforcements were received in no tone + no light for not responding. Experiment I subjects, for which tone and light were associated with response and reinforcement increase, responded significantly more to tone-plus-light than to tone or light alone (additive summation). Experiment II subjects, for which tone and light were associated with response increase and reinforcement decrease, responded comparably to tone, light, and tone + light. Thus, additive summation was observed when stimulus-response and stimulus-reinforcer associations in tone and light were both positive, but not when they were conflicting. All subjects in both experiments responded predominantly on the light-correlated lever during tone + light, even when light intensity was reduced in testing. Furthermore, when a light was presented to a subject engaged in tone-associated responding, all subjects immediately switched the locus of responding to the light-correlated lever. No change in locus occurred when a tone was presented to a subject engaged in light-associated responding, irrespective of the stimulus-reinforcer association conditioned to tone. The light-lever preference in tone + light indicates that the heightened responding observed in Experiment I was not the summation of tone-associated behavior with light-associated behavior. Rather, it appears to be the result of a facilitation of one operant (light-associated responding) by the reinforcement-associated cue for the other.
Bagley, Stephen J.; Vitale, Steven; Zhang, Suhong; Aggarwal, Charu; Evans, Tracey L.; Alley, Evan W.; Cohen, Roger B.; Langer, Corey J.; Blair, Ian A.; Vachani, Anil; Whitehead, Alexander S.
2016-01-01
Objectives Pemetrexed inhibits folate-dependent enzymes involved in pyrimidine and purine synthesis. Prior studies of genetic variation in these enzymes as predictors of pemetrexed efficacy have yielded inconsistent results. We investigated whether red blood cell (RBC) total folate, a phenotypic rather than genotypic marker of cellular folate status, was associated with response to pemetrexed-based chemotherapy in advanced non-squamous non-small-cell lung cancer (NSCLC). Materials and methods We conducted a prospective cohort study of patients with stage IV non-squamous NSCLC receiving first-line chemotherapy containing pemetrexed. Pretreatment RBC total folate was quantified using liquid chromatography/mass spectrometry. We then compared objective response rate (ORR) between patients with RBC total folate concentrations above and below an optimal cut-off value determined from the receiver operating characteristic (ROC) curve. A logistic regression model was used to adjust for age, sex, and use of bevacizumab. Results The ORR was 62% (32 of 52 patients). ROC analysis was used to establish that a RBC total folate cutoff value of 364.6 nM optimally discriminated between pemetrexed responders and non-responders. Patients with RBC total folate below 364.5 nM had an ORR of 27%, compared to 71% in patients with RBC total folate above this value (p=0.01). This difference persisted after adjusting for age, sex, and use of bevacizumab (OR 0.07, 95% CI 0.01 - 0.57, p=0.01). Conclusions Low pretreatment RBC total folate is associated with inferior response to pemetrexed-based chemotherapy in stage IV non-squamous NSCLC. Larger, multicenter studies are needed to validate RBC total folate as a predictive marker of pemetrexed response. PMID:27863923
NASA Astrophysics Data System (ADS)
Lv, Shu-Xin; Zhao, Zheng-Wei; Zhou, Ping
2018-01-01
We present a scheme for joint remote implementation of an arbitrary single-qubit operation following some ideas in one-way quantum computation. All the senders share the information of implemented quantum operation and perform corresponding single-qubit measurements according to their information of implemented operation. An arbitrary single-qubit operation can be implemented upon the remote receiver's quantum system if the receiver cooperates with all the senders. Moreover, we study the protocol of multiparty joint remote implementation of an arbitrary single-qubit operation with many senders by using a multiparticle entangled state as the quantum channel.
1993-06-01
additional source. For the past three years VNIIFTRI (Mendeleevo, Moscow Region, Russian Federation) and some other Russian time laboratories have used...Russian-built GLONASS navigation receivers for time 47 comparisons. Since June 1991, VNIIFTRI has operated a commercial CPS time receiver on loan from...the BIPM. Since February 1992, the BIPM has operated Russian GLONASS receiver on loan from the VNIIFTRI . This provides, for the first time, an
Houssami, Nehmat; Turner, Robin M; Morrow, Monica
2017-09-01
Although there is no consensus on whether pre-operative MRI in women with breast cancer (BC) benefits surgical treatment, MRI continues to be used pre-operatively in practice. This meta-analysis examines the association between pre-operative MRI and surgical outcomes in BC. A systematic review was performed to identify studies reporting quantitative data on pre-operative MRI and surgical outcomes (without restriction by type of surgery received or type of BC) and using a controlled design. Random-effects logistic regression calculated the pooled odds ratio (OR) for each surgical outcome (MRI vs. no-MRI groups), and estimated ORs stratified by study-level age. Subgroup analysis was performed for invasive lobular cancer (ILC). Nineteen studies met eligibility criteria: 3 RCTs and 16 comparative studies that included newly diagnosed BC of any type except for three studies restricted to ILC. Primary analysis (85,975 subjects) showed that pre-operative MRI was associated with increased odds of receiving mastectomy [OR 1.39 (1.23, 1.57); p < 0.001]; similar findings were shown in analyses stratified by study-level median age. Secondary analyses did not find statistical evidence of an effect of MRI on the rates of re-excision, re-operation, or positive margins; however, MRI was significantly associated with increased odds of receiving contralateral prophylactic mastectomy [OR 1.91 (1.25, 2.91); p = 0.003]. Subgroup analysis for ILC did not find any association between MRI and the odds of receiving mastectomy [OR 1.00 (0.75, 1.33); p = 0.988] or the odds of re-excision [OR 0.65 (0.35, 1.24); p = 0.192]. Pre-operative MRI is associated with increased odds of receiving ipsilateral mastectomy and contralateral prophylactic mastectomy as surgical treatment in newly diagnosed BC patients.
Radiological/Nuclear Human Monitoring Tabletop Exercise: Recommendations and Lessons Identified.
Chauhan, Vinita; Duncan, Devin; Wilkins, Ruth C
2017-06-01
Health Canada is the lead department for coordinating the federal response to a Canadian nuclear emergency event. The framework to manage a radiological consequence is outlined in the Federal Nuclear Emergency Plan (FNEP). In 2014, a full scale exercise (FSX) was held to test the capacity of the federal government to handle a nuclear facility emergency disaster in Canada. The FSX provided a means to demonstrate the integration of various departments and agencies in response to such an event, and although a number of task teams within FNEP were tested, the capacity to monitor humans for exposure post-event was not played out fully. To address this, a table top exercise (TTX) was held in 2015 that brought together experts from human monitoring groups (HMGs) in partnership with Provincial and Municipal emergency response organizations. The TTX took the form of a facilitated discussion centered around two types of radiological/nuclear (RN) emergency scenarios that commenced post-release. The purpose of the exercise was to integrate these communities and identify knowledge gaps in policies and concepts of operations pertaining to the human monitoring aspects of RN events including biodosimetry, bioassay, portal monitors, whole body counting, and the provision of personal dosimetry. It also tested the interoperability between first responders/receivers and Federal, Provincial, and Municipal emergency response organizations. The end outcome was the identification of clear knowledge gaps in existing and newly developed concepts of operation in the human population monitoring response to an RN emergency in Canada; these and possible recommendations are captured in this report.
40 CFR 445.1 - General applicability.
Code of Federal Regulations, 2010 CFR
2010-07-01
... landfill wastewater from landfills operated in conjunction with other industrial or commercial operations... landfills operated in conjunction with other industrial or commercial operations when the landfill receives... operation. (g) This part does not apply to landfills operated in conjunction with Centralized Waste...
Barrett-Muir, W; Breuer, J; Millar, C; Thomas, J; Jeffries, D; Yaqoob, M; Aitken, C
2000-07-15
Quantitative commercial assays for cytomegalovirus (CMV) detection have recently been developed. Their role in the management of patients after transplantation needs to be evaluated. Widespread use of these assays will allow for comparison of results between centers and meaningful interpretation of the significance of viral load measurements. Sequential samples from 52 patients after renal transplantation were tested in the murex hybrid capture assay (HCA) and the Roche Amplicor CMV DNA assay (QPCR) and correlated with the development of CMV disease. A comparison of viral loads in plasma and whole blood was also made. Both assays were sensitive and detected all cases of CMV disease. The specificity and positive predictive value increased from 0.34 and 0.36 to 0.85 and 0.96 for the HCA and 0.37, 0.37 to 0.72 and 0.63 for the QPCR following a receiver operator curve analysis. Higher viral loads were measured using the HCA compared to the QPCR. Response to ganciclovir was associated with a greater than 80% reduction in viral load by HCA or greater than 70% using the QPCR. Both assays were highly sensitive. By using a receiver operator curve analysis a cutoff viral load can be determined which maximizes the clinical utility of these assays.
Design of a receiver operating characteristic (ROC) study of 10:1 lossy image compression
NASA Astrophysics Data System (ADS)
Collins, Cary A.; Lane, David; Frank, Mark S.; Hardy, Michael E.; Haynor, David R.; Smith, Donald V.; Parker, James E.; Bender, Gregory N.; Kim, Yongmin
1994-04-01
The digital archiving system at Madigan Army Medical Center (MAMC) uses a 10:1 lossy data compression algorithm for most forms of computed radiography. A systematic study on the potential effect of lossy image compression on patient care has been initiated with a series of studies focused on specific diagnostic tasks. The studies are based upon the receiver operating characteristic (ROC) method of analysis for diagnostic systems. The null hypothesis is that observer performance with approximately 10:1 compressed and decompressed images is not different from using original, uncompressed images for detecting subtle pathologic findings seen on computed radiographs of bone, chest, or abdomen, when viewed on a high-resolution monitor. Our design involves collecting cases from eight pathologic categories. Truth is determined by committee using confirmatory studies performed during routine clinical practice whenever possible. Software has been developed to aid in case collection and to allow reading of the cases for the study using stand-alone Siemens Litebox workstations. Data analysis uses two methods, ROC analysis and free-response ROC (FROC) methods. This study will be one of the largest ROC/FROC studies of its kind and could benefit clinical radiology practice using PACS technology. The study design and results from a pilot FROC study are presented.
Receiver operating characteristic analysis of age-related changes in lineup performance.
Humphries, Joyce E; Flowe, Heather D
2015-04-01
In the basic face memory literature, support has been found for the late maturation hypothesis, which holds that face recognition ability is not fully developed until at least adolescence. Support for the late maturation hypothesis in the criminal lineup identification literature, however, has been equivocal because of the analytic approach that has been used to examine age-related changes in identification performance. Recently, receiver operator characteristic (ROC) analysis was applied for the first time in the adult eyewitness memory literature to examine whether memory sensitivity differs across different types of lineup tests. ROC analysis allows for the separation of memory sensitivity from response bias in the analysis of recognition data. Here, we have made the first ROC-based comparison of adults' and children's (5- and 6-year-olds and 9- and 10-year-olds) memory performance on lineups by reanalyzing data from Humphries, Holliday, and Flowe (2012). In line with the late maturation hypothesis, memory sensitivity was significantly greater for adults compared with young children. Memory sensitivity for older children was similar to that for adults. The results indicate that the late maturation hypothesis can be generalized to account for age-related performance differences on an eyewitness memory task. The implications for developmental eyewitness memory research are discussed. Copyright © 2014 Elsevier Inc. All rights reserved.
[The effect of parecoxib sodium for preemptive analgesia on nasal endoscopic surgery].
Kong, Yonggang; Yang, Xilin; Li, Xinchu
2015-08-01
To evaluate the perioperative analgesic effects of parecoxib sodium in patients undergoing nasal endoscopic surgery. In the randomized, double blind, controlled study, 120 patients undergoing septoplasty were divided into 3 groups (n = 40): A group received parecoxib at a dose of 40 mg by muscle injection 30 min before the operation followed by saline at the same volume every 24 h for 48 h; B group received parecoxib at a dose of 40 mg by muscle injection 30 min before the operation followed by 40 mg every 24 h for 48 h; C group received an equal volume of 0.9% saline at the same time points. Patients were assessed with respect to pain score (VAS), rescue analgesia requirement and the side effects during the operation as well as at 3, 24, 48 h after the surgery. Intra-operative as well as the postoperative pain scores were less in the A group and B group than in the.control group. Compared with group A, group B had significantly lower VAS score at 24 h after the operation, however there were no significant difference on other time points. Fewer participants of both the A and B groups required rescue medication after operation. Administration of parecoxib can provide ideal analgesic effects without serious adverse side effects at the perioperative period for patients who received nasal endoscopic operation. Intramuscular parecoxib (40 mg 30 min before the operation followed 40 mg qd for 48 h) designed as preoperative analgesia mode resulted in sufficient perioperative analgesia that deserves popularization in the clinical works.
Wide modulation bandwidth terahertz detection in 130 nm CMOS technology
NASA Astrophysics Data System (ADS)
Nahar, Shamsun; Shafee, Marwah; Blin, Stéphane; Pénarier, Annick; Nouvel, Philippe; Coquillat, Dominique; Safwa, Amr M. E.; Knap, Wojciech; Hella, Mona M.
2016-11-01
Design, manufacturing and measurements results for silicon plasma wave transistors based wireless communication wideband receivers operating at 300 GHz carrier frequency are presented. We show the possibility of Si-CMOS based integrated circuits, in which by: (i) specific physics based plasma wave transistor design allowing impedance matching to the antenna and the amplifier, (ii) engineering the shape of the patch antenna through a stacked resonator approach and (iii) applying bandwidth enhancement strategies to the design of integrated broadband amplifier, we achieve an integrated circuit of the 300 GHz carrier frequency receiver for wireless wideband operation up to/over 10 GHz. This is, to the best of our knowledge, the first demonstration of low cost 130 nm Si-CMOS technology, plasma wave transistors based fast/wideband integrated receiver operating at 300 GHz atmospheric window. These results pave the way towards future large scale (cost effective) silicon technology based terahertz wireless communication receivers.