Sample records for response time measures

  1. Computer Response Time Measurements of Mood, Fatigue and Symptom Scale Items: Implications for Scale Response Time Uses.

    ERIC Educational Resources Information Center

    Ryman, David H.; And Others

    1988-01-01

    Describes study conducted with U.S. Marine Corps enlisted personnel to measure response time to computer-administered questionnaire items, and to evaluate how measurement of response time might be useful in various research areas. Topics addressed include mood states; the occurrence of straight lining; and experimental effects of sleep loss and…

  2. Lighting Quality Affects Eyestrain of Operators at Sorting Station in Beverage Industry

    NASA Astrophysics Data System (ADS)

    Anizar; Erwin

    2017-03-01

    This study observes sorters’ performance in two beverage industries whose job is to separate defect products found. Sorters observe bottles quality and beverage quality continuously, therefore requiring more focused eyes which makes eyes’ load heavier. Sorters’ eyestrain causes more defect products pass the selection. In this study, measurement is conducted toward ilumintation, operators’ time response, and defect products that pass the selection. Measurement is hold in 2 beverage industries for four days with four measurements per day, twice in the morning and twice in the afternoon. Ilumination is measured with 4 in 1 environmental meter in grid 1m x 1m, while operators’ time response is measured with Flicker Fusion. Illuminance is generally higher in the morning than in the evening, but still under the standard of Indonesia. Overall, sorters’ time response is higher in the morning than in the afternoon. Higher time response shows that operators experiencing lower fatigue than lower time response. The sorting duration also affects operators’ time response and defect products which pass the selection.

  3. Estimation of Initial and Response Times of Laser Dew-Point Hygrometer by Measurement Simulation

    NASA Astrophysics Data System (ADS)

    Matsumoto, Sigeaki; Toyooka, Satoru

    1995-10-01

    The initial and the response times of the laser dew-point hygrometer were evaluated by measurement simulation. The simulation was based on loop computations of the surface temperature of a plate with dew deposition, the quantity of dew deposited and the intensity of scattered light from the surface at each short interval of measurement. The initial time was defined as the time necessary for the hygrometer to reach a temperature within ±0.5° C of the measured dew point from the start time of measurement, and the response time was also defined for stepwise dew-point changes of +5° C and -5° C. The simulation results are in approximate agreement with the recorded temperature and intensity of scattered light of the hygrometer. The evaluated initial time ranged from 0.3 min to 5 min in the temperature range from 0° C to 60° C, and the response time was also evaluated to be from 0.2 min to 3 min.

  4. Posterior Predictive Checks for Conditional Independence between Response Time and Accuracy

    ERIC Educational Resources Information Center

    Bolsinova, Maria; Tijmstra, Jesper

    2016-01-01

    Conditional independence (CI) between response time and response accuracy is a fundamental assumption of many joint models for time and accuracy used in educational measurement. In this study, posterior predictive checks (PPCs) are proposed for testing this assumption. These PPCs are based on three discrepancy measures reflecting different…

  5. Presentation and response timing accuracy in Adobe Flash and HTML5/JavaScript Web experiments.

    PubMed

    Reimers, Stian; Stewart, Neil

    2015-06-01

    Web-based research is becoming ubiquitous in the behavioral sciences, facilitated by convenient, readily available participant pools and relatively straightforward ways of running experiments: most recently, through the development of the HTML5 standard. Although in most studies participants give untimed responses, there is a growing interest in being able to record response times online. Existing data on the accuracy and cross-machine variability of online timing measures are limited, and generally they have compared behavioral data gathered on the Web with similar data gathered in the lab. For this article, we took a more direct approach, examining two ways of running experiments online-Adobe Flash and HTML5 with CSS3 and JavaScript-across 19 different computer systems. We used specialist hardware to measure stimulus display durations and to generate precise response times to visual stimuli in order to assess measurement accuracy, examining effects of duration, browser, and system-to-system variability (such as across different Windows versions), as well as effects of processing power and graphics capability. We found that (a) Flash and JavaScript's presentation and response time measurement accuracy are similar; (b) within-system variability is generally small, even in low-powered machines under high load; (c) the variability of measured response times across systems is somewhat larger; and (d) browser type and system hardware appear to have relatively small effects on measured response times. Modeling of the effects of this technical variability suggests that for most within- and between-subjects experiments, Flash and JavaScript can both be used to accurately detect differences in response times across conditions. Concerns are, however, noted about using some correlational or longitudinal designs online.

  6. Exploratory analysis of real personal emergency response call conversations: considerations for personal emergency response spoken dialogue systems.

    PubMed

    Young, Victoria; Rochon, Elizabeth; Mihailidis, Alex

    2016-11-14

    The purpose of this study was to derive data from real, recorded, personal emergency response call conversations to help improve the artificial intelligence and decision making capability of a spoken dialogue system in a smart personal emergency response system. The main study objectives were to: develop a model of personal emergency response; determine categories for the model's features; identify and calculate measures from call conversations (verbal ability, conversational structure, timing); and examine conversational patterns and relationships between measures and model features applicable for improving the system's ability to automatically identify call model categories and predict a target response. This study was exploratory and used mixed methods. Personal emergency response calls were pre-classified according to call model categories identified qualitatively from response call transcripts. The relationships between six verbal ability measures, three conversational structure measures, two timing measures and three independent factors: caller type, risk level, and speaker type, were examined statistically. Emergency medical response services were the preferred response for the majority of medium and high risk calls for both caller types. Older adult callers mainly requested non-emergency medical service responders during medium risk situations. By measuring the number of spoken words-per-minute and turn-length-in-words for the first spoken utterance of a call, older adult and care provider callers could be identified with moderate accuracy. Average call taker response time was calculated using the number-of-speaker-turns and time-in-seconds measures. Care providers and older adults used different conversational strategies when responding to call takers. The words 'ambulance' and 'paramedic' may hold different latent connotations for different callers. The data derived from the real personal emergency response recordings may help a spoken dialogue system classify incoming calls by caller type with moderate probability shortly after the initial caller utterance. Knowing the caller type, the target response for the call may be predicted with some degree of probability and the output dialogue could be tailored to this caller type. The average call taker response time measured from real calls may be used to limit the conversation length in a spoken dialogue system before defaulting to a live call taker.

  7. A method for determining the actual rate of orientation switching of DNA self-assembled monolayers using optical and electrochemical frequency response analysis.

    PubMed

    Casanova-Moreno, J; Bizzotto, D

    2015-02-17

    Electrostatic control of the orientation of fluorophore-labeled DNA strands immobilized on an electrode surface has been shown to be an effective bioanalytical tool. Modulation techniques and later time-resolved measurements were used to evaluate the kinetics of the switching between lying and standing DNA conformations. These measurements, however, are the result of a convolution between the DNA "switching" response time and the other frequency limited responses in the measurement. In this work, a method for analyzing the response of a potential driven DNA sensor is presented by calculating the potential effectively dropped across the electrode interface (using electrochemical impedance spectroscopy) as opposed to the potential applied to the electrochemical cell. This effectively deconvolutes the effect of the charging time on the observed frequency response. The corrected response shows that DNA is able to switch conformation faster than previously reported using modulation techniques. This approach will ensure accurate measurements independent of the electrochemical system, removing the uncertainty in the analysis of the switching response, enabling comparison between samples and measurement systems.

  8. Effect of time of day on the vertical spinal creep response.

    PubMed

    Puntumetakul, Rungthip; Trott, Patricia; Williams, Marie; Fulton, Ian

    2009-01-01

    Vertical spinal creep (VSC) is height loss during sustained postures over a set period of time. While total stature has been demonstrated to decrease throughout the day, whether a diurnal effect applies to the VSC response has not been reported. The aim of this study was to investigate whether time of day had an effect on the magnitude of the VSC response in young subjects asymptomatic for musculoskeletal pathologies. The VSC response was recorded over 25 min while subjects remained seated on the stadiometer, at three times (morning, midday and afternoon) on the same day, in 48 asymptomatic volunteers aged 20-39 years. While no significant differences were calculated for the magnitude of the VSC responses on the three occasions of testing, differences in magnitude of VSC response may have been confounded by preloading activities. Where magnitude of the VSC response is the primary outcome measure, measurement protocols should control preloading activities and continue to conduct measurements at the same time of day, until further studies conclusively refute the existence of a diurnal effect.

  9. Evidence of substantial development of inhibitory control and sustained attention between 6 and 8years of age on an unpredictable Go/No-Go task.

    PubMed

    Lewis, Frances C; Reeve, Robert A; Kelly, Simon P; Johnson, Katherine A

    2017-05-01

    Inhibitory control and sustained attention are important cognitive abilities; however, their developmental trajectories remain unclear. In total, 35 6-year-olds, 32 8-year-olds, and 37 10-year-olds performed a Go/No-Go task; this required frequent responding to stimuli with infrequent inhibition to a target that appeared unpredictably. Children performed this task three times over 12months. Response time variability and accuracy measures, linked to inhibition and sustained attention, were assessed. Specifically, fast Fourier transform and ex-Gaussian analyses of response time data provided several measures of response time variability; these measures are thought to represent different components of sustained attention. The 6-year-olds performed less well than the older groups on most measures. The 8-year-olds exhibited greater momentary fluctuations in response time and made more long responses than the 10-year-olds; otherwise, there were few differences between the two older groups. Response inhibition and sustained attention developed significantly between 6 and 8years of age, with subtle changes in attentional control between 8 and 11years of age. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Comparison of reliability and responsiveness of patient-reported clinical outcome measures in knee osteoarthritis rehabilitation.

    PubMed

    Williams, Valerie J; Piva, Sara R; Irrgang, James J; Crossley, Chad; Fitzgerald, G Kelley

    2012-08-01

    Secondary analysis, pretreatment-posttreatment observational study. To compare the reliability and responsiveness of the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), the Knee Outcome Survey activities of daily living subscale (KOS-ADL), and the Lower Extremity Functional Scale (LEFS) in individuals with knee osteoarthritis (OA). The WOMAC is the current standard in patient-reported measures of function in patients with knee OA. The KOS-ADL and LEFS were designed for potential use in patients with knee OA. If the KOS-ADL and LEFS are to be considered viable alternatives to the WOMAC for measuring patient-reported function in individuals with knee OA, they should have measurement properties comparable to the WOMAC. It would also be important to determine whether either of these instruments may be superior to the WOMAC in terms of reliability or responsiveness in this population. Data from 168 subjects with knee OA, who participated in a rehabilitation program, were used in the analyses. Reliability and responsiveness of each outcome measure were estimated at follow-ups of 2, 6, and 12 months. Reliability was estimated by calculating the intraclass correlation coefficient (ICC2,1) for subjects who were unchanged in status from baseline at each follow-up time, based on a global rating of change score. To examine responsiveness, the standard error of the measurement, minimal detectable change, minimal clinically important difference, and the Guyatt responsiveness index were calculated for each outcome measure at each follow-up time. All 3 outcome measures demonstrated reasonable reliability and responsiveness to change. Reliability and responsiveness tended to decrease somewhat with increasing follow-up time. There were no substantial differences between outcome measures for reliability or any of the 3 measures of responsiveness at any follow-up time. The results do not indicate that one outcome measure is more reliable or responsive than another when applied to subjects with knee OA. We believe that all 3 instruments are appropriate outcome measures to examine change in functional status of patients with knee OA.

  11. A unified method for evaluating real-time computer controllers: A case study. [aircraft control

    NASA Technical Reports Server (NTRS)

    Shin, K. G.; Krishna, C. M.; Lee, Y. H.

    1982-01-01

    A real time control system consists of a synergistic pair, that is, a controlled process and a controller computer. Performance measures for real time controller computers are defined on the basis of the nature of this synergistic pair. A case study of a typical critical controlled process is presented in the context of new performance measures that express the performance of both controlled processes and real time controllers (taken as a unit) on the basis of a single variable: controller response time. Controller response time is a function of current system state, system failure rate, electrical and/or magnetic interference, etc., and is therefore a random variable. Control overhead is expressed as a monotonically nondecreasing function of the response time and the system suffers catastrophic failure, or dynamic failure, if the response time for a control task exceeds the corresponding system hard deadline, if any. A rigorous probabilistic approach is used to estimate the performance measures. The controlled process chosen for study is an aircraft in the final stages of descent, just prior to landing. First, the performance measures for the controller are presented. Secondly, control algorithms for solving the landing problem are discussed and finally the impact of the performance measures on the problem is analyzed.

  12. Incorporating Response Times in Item Response Theory Models of Reading Comprehension Fluency

    ERIC Educational Resources Information Center

    Su, Shiyang

    2017-01-01

    With the online assessment becoming mainstream and the recording of response times becoming straightforward, the importance of response times as a measure of psychological constructs has been recognized and the literature of modeling times has been growing during the last few decades. Previous studies have tried to formulate models and theories to…

  13. Wind-instrument reflection function measurements in the time domain.

    PubMed

    Keefe, D H

    1996-04-01

    Theoretical and computational analyses of wind-instrument sound production in the time domain have emerged as useful tools for understanding musical instrument acoustics, yet there exist few experimental measurements of the air-column response directly in the time domain. A new experimental, time-domain technique is proposed to measure the reflection function response of woodwind and brass-instrument air columns. This response is defined at the location of sound regeneration in the mouthpiece or double reed. A probe assembly comprised of an acoustic source and microphone is inserted directly into the air column entryway using a foam plug to ensure a leak-free fit. An initial calibration phase involves measurements on a single cylindrical tube of known dimensions. Measurements are presented on an alto saxophone and euphonium. The technique has promise for testing any musical instrument air columns using a single probe assembly and foam plugs over a range of diameters typical of air-column entryways.

  14. Measuring older adults' sedentary time: reliability, validity, and responsiveness.

    PubMed

    Gardiner, Paul A; Clark, Bronwyn K; Healy, Genevieve N; Eakin, Elizabeth G; Winkler, Elisabeth A H; Owen, Neville

    2011-11-01

    With evidence that prolonged sitting has deleterious health consequences, decreasing sedentary time is a potentially important preventive health target. High-quality measures, particularly for use with older adults, who are the most sedentary population group, are needed to evaluate the effect of sedentary behavior interventions. We examined the reliability, validity, and responsiveness to change of a self-report sedentary behavior questionnaire that assessed time spent in behaviors common among older adults: watching television, computer use, reading, socializing, transport and hobbies, and a summary measure (total sedentary time). In the context of a sedentary behavior intervention, nonworking older adults (n = 48, age = 73 ± 8 yr (mean ± SD)) completed the questionnaire on three occasions during a 2-wk period (7 d between administrations) and wore an accelerometer (ActiGraph model GT1M) for two periods of 6 d. Test-retest reliability (for the individual items and the summary measure) and validity (self-reported total sedentary time compared with accelerometer-derived sedentary time) were assessed during the 1-wk preintervention period, using Spearman (ρ) correlations and 95% confidence intervals (CI). Responsiveness to change after the intervention was assessed using the responsiveness statistic (RS). Test-retest reliability was excellent for television viewing time (ρ (95% CI) = 0.78 (0.63-0.89)), computer use (ρ (95% CI) = 0.90 (0.83-0.94)), and reading (ρ (95% CI) = 0.77 (0.62-0.86)); acceptable for hobbies (ρ (95% CI) = 0.61 (0.39-0.76)); and poor for socializing and transport (ρ < 0.45). Total sedentary time had acceptable test-retest reliability (ρ (95% CI) = 0.52 (0.27-0.70)) and validity (ρ (95% CI) = 0.30 (0.02-0.54)). Self-report total sedentary time was similarly responsive to change (RS = 0.47) as accelerometer-derived sedentary time (RS = 0.39). The summary measure of total sedentary time has good repeatability and modest validity and is sufficiently responsive to change suggesting that it is suitable for use in interventions with older adults.

  15. A Strategy to Use Soft Data Effectively in Randomized Controlled Clinical Trials.

    ERIC Educational Resources Information Center

    Kraemer, Helena Chmura; Thiemann, Sue

    1989-01-01

    Sees soft data, measures having substantial intrasubject variability due to errors of measurement or response inconsistency, as important measures of response in randomized clinical trials. Shows that using intensive design and slope of response on time as outcome measure maximizes sample retention and decreases within-group variability, thus…

  16. Structural Equation Model Approach to the Use of Response Times for Improving Estimation in Item Response Models

    ERIC Educational Resources Information Center

    Sen, Rohini

    2012-01-01

    In the last five decades, research on the uses of response time has extended into the field of psychometrics (Schnikpe & Scrams, 1999; van der Linden, 2006; van der Linden, 2007), where interest has centered around the usefulness of response time information in item calibration and person measurement within an item response theory. framework.…

  17. Side-welded fast response sheathed thermocouple

    DOEpatents

    Carr, K.R.

    A method of fabricating the measuring junction of a grounded-junction sheathed thermocouple to obtain fast time response and good thermal cycling performance is provided. Slots are tooled or machined into the sheath wall at the measuring junction, the thermocouple wires are laser-welded into the slots. A thin metal closure cap is then laser-welded over the end of the sheath. Compared to a conventional grounded-junction thermocouple, the response time is 4 to 5 times faster and the thermal shock and cycling capabilities are substantially improved.

  18. Side-welded fast response sheathed thermocouple

    DOEpatents

    Carr, Kenneth R.

    1981-01-01

    A method of fabricating the measuring junction of a grounded-junction sheathed thermocouple to obtain fast time response and good thermal cycling performance is provided. Slots are tooled or machined into the sheath wall at the measuring junction, the thermocouple wires are laser-welded into the slots. A thin metal closure cap is then laser-welded over the end of the sheath. Compared to a conventional grounded-junction thermocouple, the response time is 4-5 times faster and the thermal shock and cycling capabilities are substantially improved.

  19. Rise time and response measurements on a LiSOCl2 cell

    NASA Technical Reports Server (NTRS)

    Bastien, Caroline; Lecomte, Eric J.

    1992-01-01

    Dynamic impedance tests were performed on a 180 Ah LiSOCl2 cell in the frame of a short term work contract awarded by Aerospatiale as part of the Hermes Space Plane development work. These tests consisted of rise time and response measurements. The rise time test was performed to show the ability to deliver 4 KW, in the nominal voltage range (75-115 V), within less than 100 microseconds, and after a period at rest of 13 days. The response measurements test consisted of step response and frequency response tests. The frequency response test was performed to characterize the response of the LiSOCl2 cell to a positive or negative load step of 10 A starting from various currents. The test was performed for various depths of discharge and various temperatures. The test results were used to build a mathematical, electrical model of the LiSOCl2 cell which are also presented. The test description, test results, electrical modelization description, and conclusions are presented.

  20. Workload Capacity: A Response Time-Based Measure of Automation Dependence.

    PubMed

    Yamani, Yusuke; McCarley, Jason S

    2016-05-01

    An experiment used the workload capacity measure C(t) to quantify the processing efficiency of human-automation teams and identify operators' automation usage strategies in a speeded decision task. Although response accuracy rates and related measures are often used to measure the influence of an automated decision aid on human performance, aids can also influence response speed. Mean response times (RTs), however, conflate the influence of the human operator and the automated aid on team performance and may mask changes in the operator's performance strategy under aided conditions. The present study used a measure of parallel processing efficiency, or workload capacity, derived from empirical RT distributions as a novel gauge of human-automation performance and automation dependence in a speeded task. Participants performed a speeded probabilistic decision task with and without the assistance of an automated aid. RT distributions were used to calculate two variants of a workload capacity measure, COR(t) and CAND(t). Capacity measures gave evidence that a diagnosis from the automated aid speeded human participants' responses, and that participants did not moderate their own decision times in anticipation of diagnoses from the aid. Workload capacity provides a sensitive and informative measure of human-automation performance and operators' automation dependence in speeded tasks. © 2016, Human Factors and Ergonomics Society.

  1. Norepinephrine genes predict response time variability and methylphenidate-induced changes in neuropsychological function in attention deficit hyperactivity disorder.

    PubMed

    Kim, Bung-Nyun; Kim, Jae-Won; Cummins, Tarrant D R; Bellgrove, Mark A; Hawi, Ziarih; Hong, Soon-Beom; Yang, Young-Hui; Kim, Hyo-Jin; Shin, Min-Sup; Cho, Soo-Churl; Kim, Ji-Hoon; Son, Jung-Woo; Shin, Yun-Mi; Chung, Un-Sun; Han, Doug-Hyun

    2013-06-01

    Noradrenergic dysfunction may be associated with cognitive impairments in attention-deficit/hyperactivity disorder (ADHD), including increased response time variability, which has been proposed as a leading endophenotype for ADHD. The aim of this study was to examine the relationship between polymorphisms in the α-2A-adrenergic receptor (ADRA2A) and norepinephrine transporter (SLC6A2) genes and attentional performance in ADHD children before and after pharmacological treatment.One hundred one medication-naive ADHD children were included. All subjects were administered methylphenidate (MPH)-OROS for 12 weeks. The subjects underwent a computerized comprehensive attention test to measure the response time variability at baseline before MPH treatment and after 12 weeks. Additive regression analyses controlling for ADHD symptom severity, age, sex, IQ, and final dose of MPH examined the association between response time variability on the comprehensive attention test measures and allelic variations in single-nucleotide polymorphisms of the ADRA2A and SLC6A2 before and after MPH treatment.Increasing possession of an A allele at the G1287A polymorphism of SLC6A2 was significantly related to heightened response time variability at baseline in the sustained (P = 2.0 × 10) and auditory selective attention (P = 1.0 × 10) tasks. Response time variability at baseline increased additively with possession of the T allele at the DraI polymorphism of the ADRA2A gene in the auditory selective attention task (P = 2.0 × 10). After medication, increasing possession of a G allele at the MspI polymorphism of the ADRA2A gene was associated with increased MPH-related change in response time variability in the flanker task (P = 1.0 × 10).Our study suggested an association between norepinephrine gene variants and response time variability measured at baseline and after MPH treatment in children with ADHD. Our results add to a growing body of evidence, suggesting that response time variability is a viable endophenotype for ADHD and suggesting its utility as a surrogate end point for measuring stimulant response in pharmacogenetic studies.

  2. Incorporating the gas analyzer response time in gas exchange computations.

    PubMed

    Mitchell, R R

    1979-11-01

    A simple method for including the gas analyzer response time in the breath-by-breath computation of gas exchange rates is described. The method uses a difference equation form of a model for the gas analyzer in the computation of oxygen uptake and carbon dioxide production and avoids a numerical differentiation required to correct the gas fraction wave forms. The effect of not accounting for analyzer response time is shown to be a 20% underestimation in gas exchange rate. The present method accurately measures gas exchange rate, is relatively insensitive to measurement errors in the analyzer time constant, and does not significantly increase the computation time.

  3. 40 CFR 1065.309 - Continuous gas analyzer system-response and updating-recording verification-for gas analyzers...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... change the system response. (b) Measurement principles. This procedure verifies that the updating and... gas detectors used to generate a continuously combined/compensated concentration measurement signal... verifies that the measurement system meets a minimum response time. For this procedure, ensure that all...

  4. The Combined Effects of Response Time and Message Content on Growth Patterns of Discussion Threads in Computer-Supported Collaborative Argumentation

    ERIC Educational Resources Information Center

    Jeong, Allan

    2004-01-01

    This study examined the effects of response time and message content on the growth patterns of discussion threads in computer-supported collaborative argumentation. Event sequence analysis was used to measure response times between threaded messages and responses containing arguments, evidence, critiques, evaluations, and other comments from…

  5. Time delay measurement in the frequency domain

    DOE PAGES

    Durbin, Stephen M.; Liu, Shih -Chieh; Dufresne, Eric M.; ...

    2015-08-06

    Pump–probe studies at synchrotrons using X-ray and laser pulses require accurate determination of the time delay between pulses. This becomes especially important when observing ultrafast responses with lifetimes approaching or even less than the X-ray pulse duration (~100 ps). The standard approach of inspecting the time response of a detector sensitive to both types of pulses can have limitations due to dissimilar pulse profiles and other experimental factors. Here, a simple alternative is presented, where the frequency response of the detector is monitored versus time delay. Measurements readily demonstrate a time resolution of ~1 ps. Improved precision is possible bymore » simply extending the data acquisition time.« less

  6. Two pilot studies of the effect of bicycling on balance and leg strength among older adults.

    PubMed

    Rissel, Chris; Passmore, Erin; Mason, Chloe; Merom, Dafna

    2013-01-01

    Study 1 examines whether age-related declines in balance are moderated by bicycling. Study 2 tests whether regular cycling can increase leg strength and improve balance. Study 1: a cross-sectional survey of 43 adults aged 44-79 was conducted. Leg strength was measured, and Balance was measured using the choice stepping reaction time (CSRT) test (decision time and response time), leg strength and timed single leg standing. Study 2: 18 older adults aged 49-72 were recruited into a 12-week cycling program. The same pre- and postmeasures as used in Study 1 were collected. Study 1: participants who had cycled in the last month performed significantly better on measures of decision time and response time. Study 2: cycling at least one hour a week was associated with significant improvements in balance (decision time and response time) and timed single leg standing. Cycling by healthy older adults appears promising for improving risk factors for falls.

  7. Two Pilot Studies of the Effect of Bicycling on Balance and Leg Strength among Older Adults

    PubMed Central

    Rissel, Chris; Passmore, Erin; Mason, Chloe; Merom, Dafna

    2013-01-01

    Objectives. Study 1 examines whether age-related declines in balance are moderated by bicycling. Study 2 tests whether regular cycling can increase leg strength and improve balance. Methods. Study 1: a cross-sectional survey of 43 adults aged 44–79 was conducted. Leg strength was measured, and Balance was measured using the choice stepping reaction time (CSRT) test (decision time and response time), leg strength and timed single leg standing. Study 2: 18 older adults aged 49–72 were recruited into a 12-week cycling program. The same pre- and postmeasures as used in Study 1 were collected. Results. Study 1: participants who had cycled in the last month performed significantly better on measures of decision time and response time. Study 2: cycling at least one hour a week was associated with significant improvements in balance (decision time and response time) and timed single leg standing. Conclusions. Cycling by healthy older adults appears promising for improving risk factors for falls. PMID:23690805

  8. Divergence compensation for hardware-in-the-loop simulation of stiffness-varying discrete contact in space

    NASA Astrophysics Data System (ADS)

    Qi, Chenkun; Zhao, Xianchao; Gao, Feng; Ren, Anye; Hu, Yan

    2016-11-01

    The hardware-in-the-loop (HIL) contact simulation for flying objects in space is challenging due to the divergence caused by the time delay. In this study, a divergence compensation approach is proposed for the stiffness-varying discrete contact. The dynamic response delay of the motion simulator and the force measurement delay are considered. For the force measurement delay, a phase lead based force compensation approach is used. For the dynamic response delay of the motion simulator, a response error based force compensation approach is used, where the compensation force is obtained from the real-time identified contact stiffness and real-time measured position response error. The dynamic response model of the motion simulator is not required. The simulations and experiments show that the simulation divergence can be compensated effectively and satisfactorily by using the proposed approach.

  9. The influence of physical and cognitive factors on reactive agility performance in men basketball players.

    PubMed

    Scanlan, Aaron; Humphries, Brendan; Tucker, Patrick S; Dalbo, Vincent

    2014-01-01

    This study explored the influence of physical and cognitive measures on reactive agility performance in basketball players. Twelve men basketball players performed multiple sprint, Change of Direction Speed Test, and Reactive Agility Test trials. Pearson's correlation analyses were used to determine relationships between the predictor variables (stature, mass, body composition, 5-m, 10-m and 20-m sprint times, peak speed, closed-skill agility time, response time and decision-making time) and reactive agility time (response variable). Simple and stepwise regression analyses determined the individual influence of each predictor variable and the best predictor model for reactive agility time. Morphological (r = -0.45 to 0.19), sprint (r = -0.40 to 0.41) and change-of-direction speed measures (r = 0.43) had small to moderate correlations with reactive agility time. Response time (r = 0.76, P = 0.004) and decision-making time (r = 0.58, P = 0.049) had large to very large relationships with reactive agility time. Response time was identified as the sole predictor variable for reactive agility time in the stepwise model (R(2) = 0.58, P = 0.004). In conclusion, cognitive measures had the greatest influence on reactive agility performance in men basketball players. These findings suggest reaction and decision-making drills should be incorporated in basketball training programmes.

  10. Annoyance due to railway vibration at different times of the day.

    PubMed

    Peris, Eulalia; Woodcock, James; Sica, Gennaro; Moorhouse, Andrew T; Waddington, David C

    2012-02-01

    The time of day when vibration occurs is considered as a factor influencing the human response to vibration. The aim of the present paper is to identify the times of day during which railway vibration causes the greatest annoyance, to measure the differences between annoyance responses for different time periods and to obtain estimates of the time of day penalties. This was achieved using data from case studies comprised of face-to-face interviews and internal vibration measurements (N=755). Results indicate that vibration annoyance differs with time of day and that separate time of day weights can be applied when considering exposure-response relationships from railway vibration in residential environments. © 2012 Acoustical Society of America

  11. Near-infrared signals associated with electrical stimulation of peripheral nerves

    NASA Astrophysics Data System (ADS)

    Fantini, Sergio; Chen, Debbie K.; Martin, Jeffrey M.; Sassaroli, Angelo; Bergethon, Peter R.

    2009-02-01

    We report our studies on the optical signals measured non-invasively on electrically stimulated peripheral nerves. The stimulation consists of the delivery of 0.1 ms current pulses, below the threshold for triggering any visible motion, to a peripheral nerve in human subjects (we have studied the sural nerve and the median nerve). In response to electrical stimulation, we observe an optical signal that peaks at about 100 ms post-stimulus, on a much longer time scale than the few milliseconds duration of the electrical response, or sensory nerve action potential (SNAP). While the 100 ms optical signal we measured is not a direct optical signature of neural activation, it is nevertheless indicative of a mediated response to neural activation. We argue that this may provide information useful for understanding the origin of the fast optical signal (also on a 100 ms time scale) that has been measured non-invasively in the brain in response to cerebral activation. Furthermore, the optical response to peripheral nerve activation may be developed into a diagnostic tool for peripheral neuropathies, as suggested by the delayed optical signals (average peak time: 230 ms) measured in patients with diabetic neuropathy with respect to normal subjects (average peak time: 160 ms).

  12. Non-invasive cortisol measurements as indicators of physiological stress responses in guinea pigs

    PubMed Central

    Pschernig, Elisabeth; Wallner, Bernard; Millesi, Eva

    2016-01-01

    Non-invasive measurements of glucocorticoid (GC) concentrations, including cortisol and corticosterone, serve as reliable indicators of adrenocortical activities and physiological stress loads in a variety of species. As an alternative to invasive analyses based on plasma, GC concentrations in saliva still represent single-point-of-time measurements, suitable for studying short-term or acute stress responses, whereas fecal GC metabolites (FGMs) reflect overall stress loads and stress responses after a species-specific time frame in the long-term. In our study species, the domestic guinea pig, GC measurements are commonly used to indicate stress responses to different environmental conditions, but the biological relevance of non-invasive measurements is widely unknown. We therefore established an experimental protocol based on the animals’ natural stress responses to different environmental conditions and compared GC levels in plasma, saliva, and fecal samples during non-stressful social isolations and stressful two-hour social confrontations with unfamiliar individuals. Plasma and saliva cortisol concentrations were significantly increased directly after the social confrontations, and plasma and saliva cortisol levels were strongly correlated. This demonstrates a high biological relevance of GC measurements in saliva. FGM levels measured 20 h afterwards, representing the reported mean gut passage time based on physiological validations, revealed that the overall stress load was not affected by the confrontations, but also no relations to plasma cortisol levels were detected. We therefore measured FGMs in two-hour intervals for 24 h after another social confrontation and detected significantly increased levels after four to twelve hours, reaching peak concentrations already after six hours. Our findings confirm that non-invasive GC measurements in guinea pigs are highly biologically relevant in indicating physiological stress responses compared to circulating levels in plasma in the short- and long-term. Our approach also underlines the importance of detailed investigations on how to use and interpret non-invasive measurements, including the determination of appropriate time points for sample collections. PMID:26839750

  13. A Measurement Model for Likert Responses that Incorporates Response Time

    ERIC Educational Resources Information Center

    Ferrando, Pere J.; Lorenzo-Seva, Urbano

    2007-01-01

    This article describes a model for response times that is proposed as a supplement to the usual factor-analytic model for responses to graded or more continuous typical-response items. The use of the proposed model together with the factor model provides additional information about the respondent and can potentially increase the accuracy of the…

  14. Measurements of speed of response of high-speed visible and IR optical detectors

    NASA Technical Reports Server (NTRS)

    Rowe, H. E.; Osmundson, J. S.

    1972-01-01

    A technique for measuring speed of response of high speed visible and IR optical detectors to mode-locked Nd:YAG laser pulses is described. Results of measurements of response times of four detectors are presented. Three detectors that can be used as receivers in a 500-MHz optical communication system are tested.

  15. DART: A Microcomputer Program for Response Latency Analysis.

    ERIC Educational Resources Information Center

    Greene, John O.; Greene, Barry F.

    1987-01-01

    Discusses how chronometric measures such as the DART (Display And Response Timing) computer program, have become virtually indispensable in testing cognitive theories of human social behavior. Describes how the DART (1) provides a way to collect response latency data; and (2) allows measurement of response latencies to a set of user-specified,…

  16. [Quenched fluorescein: a reference dye for instrument response function of TCSPC].

    PubMed

    Pan, Hai-feng; Ding, Jing-xin; Liang, Rong-rong; Tao, Zhan-dong; Liu, Meng-wei; Zhang, San-jun; Xu, Jian-hua

    2014-08-01

    Measuring the instrument response function (IRF) and fitting by reconvolution algorithms are routines to improve time resolution in fluorescence lifetime measurements. Iodide ions were successfully used to quench the fluorescence of fluorescein in this study. By systematically adding saturated NaI water solution in basic fluorescein solution, the lifetimes of fluorescein were reduced from 4 ns to 24 ps. The quenched lifetime of fluorescein obtained from the analysis of Time-Correlated Single Photon Counting (TCSPC) measurement agrees well with that from femtosecond frequency up-conversion measurement. In time resolved excitation spectra measurements, the IRF should be measured at various detection wavelengths providing scattring materials are used. This study could not only reduce the complexity of IRF measurement, but also avoid the existing color effect in system. This study should have wide applications in time resolved fluorescence spectroscopy and fluorescence lifetime imaging.

  17. Instantaneous velocity measurement of AC electroosmotic flows by laser induced fluorescence photobleaching anemometer with high temporal resolution

    NASA Astrophysics Data System (ADS)

    Zhao, Wei; Yang, Fang; Qiao, Rui; Wang, Guiren; Rui Qiao Collaboration

    2015-11-01

    Understanding the instantaneous response of flows to applied AC electric fields may help understand some unsolved issues in induced-charge electrokinetics and enhance performance of microfluidic devices. Since currently available velocimeters have difficulty in measuring velocity fluctuations with frequency higher than 1 kHz, most experimental studies so far focus only on the average velocity measurement in AC electrokinetic flows. Here, we present measurements of AC electroosmotic flow (AC-EOF) response time in microchannels by a novel velocimeter with submicrometer spatial resolution and microsecond temporal resolution, i.e. laser-induced fluorescence photobleaching anemometer (LIFPA). Several parameters affecting the AC-EOF response time to the applied electric signal were investigated, i.e. channel length, transverse position and solution conductivity. The experimental results show that the EOF response time under a pulsed electric field decreases with the reduction of the microchannel length, distance between the detection position to the wall and the conductivity of the solution. This work could provide a new powerful tool to measure AC electrokinetics and enhance our understanding of AC electrokinetic flows.

  18. In-situ response time testing of thermocouples

    NASA Astrophysics Data System (ADS)

    Hashemian, H. M.; Petersen, K. M.; Hashemian, M.; Beverly, D. D.; Miller, L. F.

    The Loop Current Step Response (LCSR) method has been developed for in situ response time testing of thermocouples and resistance thermometers. A means for measuring the sensor response for actual operating conditions and installation details is provided. This technology is ready to be assembled into an instrument for use in aerospace, nuclear, chemical and other industries where transient temperature measurements are important. The method provides time constant results within better than about 20 percent of value obtained from plunge tests. These results are based on tests performed in water at low flow rates (1M/sec) and in air flow rates ranging from a few meters per second to over a hundred kilometers per hour.

  19. Transient photoconductivity in the ferromagnetic semiconductor CdCr2Se4

    NASA Technical Reports Server (NTRS)

    Walser, A. D.; Alfano, R. R.

    1988-01-01

    The transient photoconductive response time of the ferromagnetic semiconductor CdCr2Se4 was measured to be smaller than 90 ps, the response time of the scope. The measurements were performed at room temperature (300 K) for 0.53 and 1.06 microns excitations using a mode locked frequency-doubled YAG laser.

  20. Systems for measuring response statistics of gigahertz bandwidth photomultipliers

    NASA Technical Reports Server (NTRS)

    Abshire, J. B.; Rowe, H. E.

    1977-01-01

    New systems have been developed for measuring the average impulse response, the pulse-height spectrum, the transit-time statistics as a function of signal level, and the dark-count spectrum of gigahertz bandwidth photomultipliers. Measurements showed that the 0.53 microns pulse used as an optical test source had a 30 picoseconds and less than 70 ps pulse width. Calibration data showed the system resolution to be less than 20 ps for root mean square transit-time measurements. Test data for a static crossed-field photomultiplier showed 2-photoelectron resolution and less than 30-ps time jitter over the 1- to 100-photoelectron range.

  1. Responsiveness of performance-based outcome measures for mobility, balance, muscle strength and manual dexterity in adults with myotonic dystrophy type 1.

    PubMed

    Kierkegaard, Marie; Petitclerc, Émilie; Hébert, Luc J; Mathieu, Jean; Gagnon, Cynthia

    2018-02-28

    To assess changes and responsiveness in outcome measures of mobility, balance, muscle strength and manual dexterity in adults with myotonic dystrophy type 1. A 9-year longitudinal study conducted with 113 patients. The responsiveness of the Timed Up and Go test, Berg Balance Scale, quantitative muscle testing, grip and pinch-grip strength, and Purdue Pegboard Test was assessed using criterion and construct approaches. Patient-reported perceived changes (worse/stable) in balance, walking, lower-limb weakness, stair-climbing and hand weakness were used as criteria. Predefined hypotheses about expected area under the receiver operating characteristic curves (criterion approach) and correlations between relative changes (construct approach) were explored. The direction and magnitude of median changes in outcome measures corresponded with patient-reported changes. Median changes in the Timed Up and Go test, grip strength, pinch-grip strength and Purdue Pegboard Test did not, in general, exceed known measurement errors. Most criterion (72%) and construct (70%) approach hypotheses were supported. Promising responsiveness was found for outcome measures of mobility, balance and muscle strength. Grip strength and manual dexterity measures showed poorer responsiveness. The performance-based outcome measures captured changes over the 9-year period and responsiveness was promising. Knowledge of measurement errors is needed to interpret the meaning of these longitudinal changes.

  2. Reliability and discriminative validity of sudden ankle inversion measurements in patients with chronic ankle instability.

    PubMed

    Eechaute, Christophe; Vaes, Peter; Duquet, William; Van Gheluwe, Bart

    2009-07-01

    Studies investigating peroneal muscle reaction times in chronically unstable ankle joints present conflicting results. The degree of reliability and accuracy of these measurements is unknown in patients with chronic ankle instability (CAI). 40 patients with CAI and 30 healthy subjects were tested using a sudden ankle inversion of 50 degrees while standing on a trapdoor device. Sudden ankle inversion measurements were registered using electromyography, accelerometry and electrogoniometry. For reliability testing, intra-class coefficients (ICCs; model 3,1) and standard errors of measurements of the latency time, motor response time and electromechanical delay of the peroneus longus muscle, the time and angular position of onset of decelerations, the mean and maximum inversion speed and the total inversion time were calculated in 15 patients with CAI. To assess between-group differences, t-tests for independent samples (p<.05) were used. ICCs ranged from .20 (angular position of onset of the second deceleration) to .98 (electromechanical delay of the peroneus longus muscle). Significant between-group differences were observed in only 2 of the 12 variables (for the electromechanical delay of the peroneus longus muscle, p=.001; time of onset of the second deceleration, p=.040). The latency time and motor response time of the peroneus longus muscle, the total inversion time and the mean inversion speed demonstrate acceptable reliability in healthy subjects and patients. The latency time and motor response time of the peroneus longus muscle are not delayed in patients with CAI. Ankle inversion measurements are not discriminative for CAI.

  3. Scalable and responsive event processing in the cloud

    PubMed Central

    Suresh, Visalakshmi; Ezhilchelvan, Paul; Watson, Paul

    2013-01-01

    Event processing involves continuous evaluation of queries over streams of events. Response-time optimization is traditionally done over a fixed set of nodes and/or by using metrics measured at query-operator levels. Cloud computing makes it easy to acquire and release computing nodes as required. Leveraging this flexibility, we propose a novel, queueing-theory-based approach for meeting specified response-time targets against fluctuating event arrival rates by drawing only the necessary amount of computing resources from a cloud platform. In the proposed approach, the entire processing engine of a distinct query is modelled as an atomic unit for predicting response times. Several such units hosted on a single node are modelled as a multiple class M/G/1 system. These aspects eliminate intrusive, low-level performance measurements at run-time, and also offer portability and scalability. Using model-based predictions, cloud resources are efficiently used to meet response-time targets. The efficacy of the approach is demonstrated through cloud-based experiments. PMID:23230164

  4. Measurements of NaI(Tl) Electron Response: Comparison of Different Samples

    NASA Astrophysics Data System (ADS)

    Hull, Giulia; Choong, Woon-Seng; Moses, William W.; Bizarri, Gregory; Valentine, John D.; Payne, Stephen A.; Cherepy, Nerine J.; Reutter, Bryan W.

    2009-02-01

    This paper measures the sample to sample variation in the light yield proportionality of NaI(Tl), and so explores whether this is an invariant characteristic of the material or whether it depends on the chemical and physical properties of the tested samples. We report on the electron response of nine crystals of NaI(Tl), differing in shape, volume, age, manufacturer and quality. The proportionality has been measured at the SLYNCI facility in the energy range between 3.5 to 460 keV. We observe that while samples produced by the same manufacturer at approximately the same time have virtually identical electron response curves, there are significant sample to sample variations among crystals produced by different manufacturers or at different times. In an effort to correlate changes in the electron response with details of the scintillation mechanism, we characterized other scintillation properties, including the gamma response and the x-ray excited emission spectra and decay times, for the nine crystals. While sample to sample differences in these crystals were observed, we have been unable to identify the underlying fundamental mechanisms that are responsible for these differences.

  5. On Some Stopping Times of Citation Processes. From Theory to Indicators.

    ERIC Educational Resources Information Center

    Glanzel, Wolfgang

    1992-01-01

    Proposes a new measure of the citation speed of scientific publications based on a stopping time approach. The stochastic process approach in bibliometrics is described, mean response time (MRT) is discussed, harmonic mean response time (HMRT) is explained, and examples are given. (six references) (LRW)

  6. On the validity of measuring change over time in routine clinical assessment: a close examination of item-level response shifts in psychosomatic inpatients.

    PubMed

    Nolte, S; Mierke, A; Fischer, H F; Rose, M

    2016-06-01

    Significant life events such as severe health status changes or intensive medical treatment often trigger response shifts in individuals that may hamper the comparison of measurements over time. Drawing from the Oort model, this study aims at detecting response shift at the item level in psychosomatic inpatients and evaluating its impact on the validity of comparing repeated measurements. Complete pretest and posttest data were available from 1188 patients who had filled out the ICD-10 Symptom Rating (ISR) scale at admission and discharge, on average 24 days after intake. Reconceptualization, reprioritization, and recalibration response shifts were explored applying tests of measurement invariance. In the item-level approach, all model parameters were constrained to be equal between pretest and posttest. If non-invariance was detected, these were linked to the different types of response shift. When constraining across-occasion model parameters, model fit worsened as indicated by a significant Satorra-Bentler Chi-square difference test suggesting potential presence of response shifts. A close examination revealed presence of two types of response shift, i.e., (non)uniform recalibration and both higher- and lower-level reconceptualization response shifts leading to four model adjustments. Our analyses suggest that psychosomatic inpatients experienced some response shifts during their hospital stay. According to the hierarchy of measurement invariance, however, only one of the detected non-invariances is critical for unbiased mean comparisons over time, which did not have a substantial impact on estimating change. Hence, the use of the ISR can be recommended for outcomes assessment in clinical routine, as change score estimates do not seem hampered by response shift effects.

  7. Recovery of balance function among individuals with total knee arthroplasty: Comparison of responsiveness among four balance tests.

    PubMed

    Chan, Andy C M; Ouyang, Xi H; Jehu, Deborah A M; Chung, Raymond C K; Pang, Marco Y C

    2018-01-01

    Balance deficits are common after total knee arthroplasty (TKA); however the responsiveness of commonly used balance measurement tools has not been well defined. The objective of this prospective study was to compare the internal and external responsiveness of four measurement tools in assessing recovery of balance function following TKA. A total of 134 individuals with TKA (95 women; age: 66.3±6.6years) completed the Balance Evaluation Systems Test (BESTest), Mini-BESTest, Brief-BESTest, and Berg Balance Scale (BBS) at 2, 4, 8, 12, and 24 weeks post-TKA. The Functional Gait Assessment (FGA) served as the anchor measure, and was also measured across these time points. Internal responsiveness was indicated by the standardized response mean (SRM), while external responsiveness was reflected by the degree of association of the changes of balance scores with those of FGA. The SRM ranged from 0.60-1.14 for the BESTest, 0.40-0.94 for the Mini-BESTest, 0.27-0.91 for the Brief-BESTest, and 0.19-0.70 for the BBS, over time. The change in BESTest and Mini-BESTest scores predicted the change in the FGA scores across all time periods, except for the Mini-BESTest between weeks 12-24, accounting for 13-27%, and 12-24% of the variance, respectively. The Brief-BESTest scores only predicted FGA scores between the weeks 2-4 (R 2 =20%). The changes in BBS scores were not associated with the FGA. The BESTest is the most responsive in measuring recovery of balance among individuals with TKA. The Mini-BESTest is a reasonable option during time constraints. Copyright © 2017. Published by Elsevier B.V.

  8. Respiratory sinus arrhythmia responses to induced emotional states: effects of RSA indices, emotion induction method, age, and sex.

    PubMed

    Overbeek, Thérèse J M; van Boxtel, Anton; Westerink, Joyce H D M

    2012-09-01

    The literature shows large inconsistencies in respiratory sinus arrhythmia (RSA) responses to induced emotional states. This may be caused by differences in emotion induction methods, RSA quantification, and non-emotional demands of the situation. In 83 healthy subjects, we studied RSA responses to pictures and film fragments eliciting six different discrete emotions relative to neutral baseline stimuli. RSA responses were quantified in the time and frequency domain and were additionally corrected for differences in mean heart rate and respiration rate, resulting in eight different RSA response measures. Subjective ratings of emotional stimuli and facial electromyographic responses indicated that pictures and film fragments elicited the intended emotions. Although RSA measures showed various emotional effects, responses were quite heterogeneous and frequently nonsignificant. They were substantially influenced by methodological factors, in particular time vs. frequency domain response measures, correction for changes in respiration rate, use of pictures vs. film fragments, and sex of participants. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Step responses of a torsional system with multiple clearances: Study of vibro-impact phenomenon using experimental and computational methods

    NASA Astrophysics Data System (ADS)

    Oruganti, Pradeep Sharma; Krak, Michael D.; Singh, Rajendra

    2018-01-01

    Recently Krak and Singh (2017) proposed a scientific experiment that examined vibro-impacts in a torsional system under a step down excitation and provided preliminary measurements and limited non-linear model studies. A major goal of this article is to extend the prior work with a focus on the examination of vibro-impact phenomena observed under step responses in a torsional system with one, two or three controlled clearances. First, new measurements are made at several locations with a higher sampling frequency. Measured angular accelerations are examined in both time and time-frequency domains. Minimal order non-linear models of the experiment are successfully constructed, using piecewise linear stiffness and Coulomb friction elements; eight cases of the generic system are examined though only three are experimentally studied. Measured and predicted responses for single and dual clearance configurations exhibit double sided impacts and time varying periods suggest softening trends under the step down torque. Non-linear models are experimentally validated by comparing results with new measurements and with those previously reported. Several metrics are utilized to quantify and compare the measured and predicted responses (including peak to peak accelerations). Eigensolutions and step responses of the corresponding linearized models are utilized to better understand the nature of the non-linear dynamic system. Finally, the effect of step amplitude on the non-linear responses is examined for several configurations, and hardening trends are observed in the torsional system with three clearances.

  10. A cavity radiometer for Earth albedo measurement, phase 1

    NASA Technical Reports Server (NTRS)

    1987-01-01

    Radiometric measurements of the directional albedo of the Earth requires a detector with a flat response from 0.2 to 50 microns, a response time of about 2 seconds, a sensitivity of the order of 0.02 mw/sq cm, and a measurement uncertainty of less than 5 percent. Absolute cavity radiometers easily meet the spectral response and accuracy requirements for Earth albedo measurements, but the radiometers available today lack the necessary sensitivity and response time. The specific innovations addressed were the development of a very low thermal mass cavity and printed/deposited thermocouple sensing elements which were incorporated into the radiometer design to produce a sensitive, fast response, absolute radiometer. The cavity is applicable to the measurement of the reflected and radiated fluxes from the Earth surface and lower atmosphere from low Earth orbit satellites. The effort consisted of requirements and thermal analysis; design, construction, and test of prototype elements of the black cavity and sensor elements to show proof-of-concept. The results obtained indicate that a black body cavity sensor that has inherently a flat response from 0.2 to 50 microns can be produced which has a sensitivity of at least 0.02 mw/sq cm per micro volt ouput and with a time constant of less than two seconds. Additional work is required to develop the required thermopile.

  11. Reducing ambulance response times using discrete event simulation.

    PubMed

    Wei Lam, Sean Shao; Zhang, Zhong Cheng; Oh, Hong Choon; Ng, Yih Ying; Wah, Win; Hock Ong, Marcus Eng

    2014-01-01

    The objectives of this study are to develop a discrete-event simulation (DES) model for the Singapore Emergency Medical Services (EMS), and to demonstrate the utility of this DES model for the evaluation of different policy alternatives to improve ambulance response times. A DES model was developed based on retrospective emergency call data over a continuous 6-month period in Singapore. The main outcome measure is the distribution of response times. The secondary outcome measure is ambulance utilization levels based on unit hour utilization (UHU) ratios. The DES model was used to evaluate different policy options in order to improve the response times, while maintaining reasonable fleet utilization. Three policy alternatives looking at the reallocation of ambulances, the addition of new ambulances, and alternative dispatch policies were evaluated. Modifications of dispatch policy combined with the reallocation of existing ambulances were able to achieve response time performance equivalent to that of adding 10 ambulances. The median (90th percentile) response time was 7.08 minutes (12.69 minutes). Overall, this combined strategy managed to narrow the gap between the ideal and existing response time distribution by 11-13%. Furthermore, the median UHU under this combined strategy was 0.324 with an interquartile range (IQR) of 0.047 versus a median utilization of 0.285 (IQR of 0.051) resulting from the introduction of additional ambulances. Response times were shown to be improved via a more effective reallocation of ambulances and dispatch policy. More importantly, the response time improvements were achieved without a reduction in the utilization levels and additional costs associated with the addition of ambulances. We demonstrated the effective use of DES as a versatile platform to model the dynamic system complexities of Singapore's national EMS systems for the evaluation of operational strategies to improve ambulance response times.

  12. Motivational Influences on Response Inhibition Measures

    ERIC Educational Resources Information Center

    Leotti, Lauren A.; Wager, Tor D.

    2010-01-01

    Psychological research has placed great emphasis on inhibitory control due to its integral role in normal cognition and clinical disorders. The stop-signal task and associated measure--stop-signal reaction time (SSRT)--provides a well-established paradigm for measuring response inhibition. However, motivational influences on stop-signal…

  13. A Method for Response Time Measurement of Electrosensitive Protective Devices.

    PubMed

    Dźwiarek, Marek

    1996-01-01

    A great step toward the improvement of safety at work was made when electrosensitive protective devices (ESPDs) were applied to the protection of press and robot-assisted manufacturing system operators. The way the device is mounted is crucial. The parameters of ESPD mounting that ensure safe distance from the controlled dangerous zone are response time, sensitivity, and the dimensions of the detection zone. The proposed experimental procedure of response time measurement is realized in two steps, with a test piece penetrating the detection zone twice. In the first step, low-speed penetration (at a speed v m ) enables the detection zone border to be localized. In the second step of measurement, the probe is injected at a high speed V d . The actuator rod position is measured and when it is equal to the value L registered by the earlier measurements, counting time begins as well as the monitoring of the state of the equipment under test (EUT) output relays. After the state changes, time tp is registered. The experimental procedure is realized on a special experimental stand. Because the stand has been constructed for certification purposes, the design satisfies the requirements imposed by Polski Komitet Normalizacyjny (PKN, 1995). The experimental results prove the measurement error to be smaller than ± 0.6 ms.

  14. Validity of the Instrumented Push and Release Test to Quantify Postural Responses in Persons With Multiple Sclerosis.

    PubMed

    El-Gohary, Mahmoud; Peterson, Daniel; Gera, Geetanjali; Horak, Fay B; Huisinga, Jessie M

    2017-07-01

    To test the validity of wearable inertial sensors to provide objective measures of postural stepping responses to the push and release clinical test in people with multiple sclerosis. Cross-sectional study. University medical center balance disorder laboratory. Total sample N=73; persons with multiple sclerosis (PwMS) n=52; healthy controls n=21. Stepping latency, time and number of steps required to reach stability, and initial step length were calculated using 3 inertial measurement units placed on participants' lumbar spine and feet. Correlations between inertial sensor measures and measures obtained from the laboratory-based systems were moderate to strong and statistically significant for all variables: time to release (r=.992), latency (r=.655), time to stability (r=.847), time of first heel strike (r=.665), number of steps (r=.825), and first step length (r=.592). Compared with healthy controls, PwMS demonstrated a longer time to stability and required a larger number of steps to reach stability. The instrumented push and release test is a valid measure of postural responses in PwMS and could be used as a clinical outcome measures for patient care decisions or for clinical trials aimed at improving postural control in PwMS. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. Measurement techniques investigated for detection of hydrogen chloride gas in ambient air

    NASA Technical Reports Server (NTRS)

    Gregory, G. L.

    1976-01-01

    Nine basic techniques are discussed, ranging from concentration (parts per million) to dosage only (parts per million-seconds) measurement techniques. Data for each technique include lower detection limit, response time, instrument status, and in some cases, specificity. Several techniques discussed can detect ambient hydrogen chloride concentrations below 1 part per million with a response time of seconds.

  16. A General Approach to Measuring Test-Taking Effort on Computer-Based Tests

    ERIC Educational Resources Information Center

    Wise, Steven L.; Gao, Lingyun

    2017-01-01

    There has been an increased interest in the impact of unmotivated test taking on test performance and score validity. This has led to the development of new ways of measuring test-taking effort based on item response time. In particular, Response Time Effort (RTE) has been shown to provide an assessment of effort down to the level of individual…

  17. Active doublet method for measuring small changes in physical properties

    DOEpatents

    Roberts, Peter M.; Fehler, Michael C.; Johnson, Paul A.; Phillips, W. Scott

    1994-01-01

    Small changes in material properties of a work piece are detected by measuring small changes in elastic wave velocity and attenuation within a work piece. Active, repeatable source generate coda wave responses from a work piece, where the coda wave responses are temporally displaced. By analyzing progressive relative phase and amplitude changes between the coda wave responses as a function of elapsed time, accurate determinations of velocity and attenuation changes are made. Thus, a small change in velocity occurring within a sample region during the time periods between excitation origin times (herein called "doublets") will produce a relative delay that changes with elapsed time over some portion of the scattered waves. This trend of changing delay is easier to detect than an isolated delay based on a single arrival and provides a direct measure of elastic wave velocity changes arising from changed material properties of the work piece.

  18. Person-Fit Statistics for Joint Models for Accuracy and Speed

    ERIC Educational Resources Information Center

    Fox, Jean-Paul; Marianti, Sukaesi

    2017-01-01

    Response accuracy and response time data can be analyzed with a joint model to measure ability and speed of working, while accounting for relationships between item and person characteristics. In this study, person-fit statistics are proposed for joint models to detect aberrant response accuracy and/or response time patterns. The person-fit tests…

  19. A common fluence threshold for first positive and second positive phototropism in Arabidopsis thaliana

    NASA Technical Reports Server (NTRS)

    Janoudi, A.; Poff, K. L.

    1990-01-01

    The relationship between the amount of light and the amount of response for any photobiological process can be based on the number of incident quanta per unit time (fluence rate-response) or on the number of incident quanta during a given period of irradiation (fluence-response). Fluence-response and fluence rate-response relationships have been measured for second positive phototropism by seedlings of Arabidopsis thaliana. The fluence-response relationships exhibit a single limiting threshold at about 0.01 micromole per square meter when measured at fluence rates from 2.4 x 10(-5) to 6.5 x 10(-3) micromoles per square meter per second. The threshold values in the fluence rate-response curves decrease with increasing time of irradiation, but show a common fluence threshold at about 0.01 micromole per square meter. These thresholds are the same as the threshold of about 0.01 micromole per square meter measured for first positive phototropism. Based on these data, it is suggested that second positive curvature has a threshold in time of about 10 minutes. Moreover, if the times of irradiation exceed the time threshold, there is a single limiting fluence threshold at about 0.01 micromole per square meter. Thus, the limiting fluence threshold for second positive phototropism is the same as the fluence threshold for first positive phototropism. Based on these data, we suggest that this common fluence threshold for first positive and second positive phototropism is set by a single photoreceptor pigment system.

  20. Measuring Intervention Effectiveness: The Benefits of an Item Response Theory Approach

    ERIC Educational Resources Information Center

    McEldoon, Katherine; Cho, Sun-Joo; Rittle-Johnson, Bethany

    2012-01-01

    Assessing the effectiveness of educational interventions relies on quantifying differences between interventions groups over time in a between-within design. Binary outcome variables (e.g., correct responses versus incorrect responses) are often assessed. Widespread approaches use percent correct on assessments, and repeated measures analysis of…

  1. Norepinephrine and impulsivity: Effects of acute yohimbine

    PubMed Central

    Swann, Alan C.; Lijffijt, Marijn; Lane, Scott D.; Cox, Blake; Steinberg, Joel L.; Moeller, F. Gerard

    2013-01-01

    Rationale Rapid-response impulsivity, characterized by inability to withhold response to a stimulus until it is adequately appraised, is associated with risky behavior and may be increased in a state-dependent manner by norepinephrine. Objective We assessed effects of yohimbine, which increases norepinephrine release by blocking alpha-2 noradrenergic receptors, on plasma catecholamine metabolites, blood pressure, subjective symptoms, and laboratory-measured rapid-response impulsivity. Methods Subjects were twenty-three healthy controls recruited from the community, with normal physical examination and ECG, and negative history for hypertension, cardiovascular illness, and Axis I or II disorder. Blood pressure, pulse, and behavioral measures were obtained before and periodically after 0.4 mg/kg oral yohimbine or placebo in a randomized, counterbalanced design. Metabolites of norepinephrine (3-methoxy-4-hydroxyphenylglycol, MHPG; vanillylmandelic acid, VMA) and dopamine (homovanillic acid, HVA) were measured by high pressure liquid chromatography with electrochemical detection. Rapid-response impulsivity was measured by commission errors and reaction times on the Immediate Memory Task (IMT), a continuous performance test designed to measure impulsivity and attention. Results Yohimbine increased plasma MHPG and VMA but not HVA. Yohimbine increased systolic and diastolic blood pressure and pulse rate. On the IMT, yohimbine increased impulsive errors and impulsive response bias and accelerated reaction times. Yohimbine-associated increase in plasma MHPG correlated with increased impulsive response rates. Time courses varied; effects on blood pressure generally preceded those on metabolites and test performance. Conclusions These effects are consistent with increased rapid-response impulsivity after pharmacological noradrenergic stimulation in healthy controls. Labile noradrenergic responses, or increased sensitivity to norepinephrine, may increase risk for impulsive behavior. PMID:23559222

  2. Age-related changes in human posture control: Motor coordination tests

    NASA Technical Reports Server (NTRS)

    Peterka, R. J.; Black, F. O.

    1989-01-01

    Postural responses to support surface displacements were measured in 214 normal human subjects ranging in age from 7 to 81 years. Motor tests measured leg muscle Electromyography (EMG) latencies, body sway, and the amplitude and timing of changes in center of pressure displacements in response to sudden forward and backward horizontal translations of the support surface upon which the subjects stood. There were small increases in both EMG latencies and the time to reach the peak amplitude of center of pressure responses with increasing age. The amplitude of center of pressure responses showed little change with age if the amplitude measures were normalized by a factor related to subject height. In general, postural responses to sudden translations showed minimal changes with age, and all age related trends which were identified were small relative to the variability within the population.

  3. Improving the psychometric properties of dot-probe attention measures using response-based computation.

    PubMed

    Evans, Travis C; Britton, Jennifer C

    2018-09-01

    Abnormal threat-related attention in anxiety disorders is most commonly assessed and modified using the dot-probe paradigm; however, poor psychometric properties of reaction-time measures may contribute to inconsistencies across studies. Typically, standard attention measures are derived using average reaction-times obtained in experimentally-defined conditions. However, current approaches based on experimentally-defined conditions are limited. In this study, the psychometric properties of a novel response-based computation approach to analyze dot-probe data are compared to standard measures of attention. 148 adults (19.19 ± 1.42 years, 84 women) completed a standardized dot-probe task including threatening and neutral faces. We generated both standard and response-based measures of attention bias, attentional orientation, and attentional disengagement. We compared overall internal consistency, number of trials necessary to reach internal consistency, test-retest reliability (n = 72), and criterion validity obtained using each approach. Compared to standard attention measures, response-based measures demonstrated uniformly high levels of internal consistency with relatively few trials and varying improvements in test-retest reliability. Additionally, response-based measures demonstrated specific evidence of anxiety-related associations above and beyond both standard attention measures and other confounds. Future studies are necessary to validate this approach in clinical samples. Response-based attention measures demonstrate superior psychometric properties compared to standard attention measures, which may improve the detection of anxiety-related associations and treatment-related changes in clinical samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Development of on-line laser power monitoring system

    NASA Astrophysics Data System (ADS)

    Ding, Chien-Fang; Lee, Meng-Shiou; Li, Kuan-Ming

    2016-03-01

    Since the laser was invented, laser has been applied in many fields such as material processing, communication, measurement, biomedical engineering, defense industries and etc. Laser power is an important parameter in laser material processing, i.e. laser cutting, and laser drilling. However, the laser power is easily affected by the environment temperature, we tend to monitor the laser power status, ensuring there is an effective material processing. Besides, the response time of current laser power meters is too long, they cannot measure laser power accurately in a short time. To be more precisely, we can know the status of laser power and help us to achieve an effective material processing at the same time. To monitor the laser power, this study utilize a CMOS (Complementary metal-oxide-semiconductor) camera to develop an on-line laser power monitoring system. The CMOS camera captures images of incident laser beam after it is split and attenuated by beam splitter and neutral density filter. By comparing the average brightness of the beam spots and measurement results from laser power meter, laser power can be estimated. Under continuous measuring mode, the average measuring error is about 3%, and the response time is at least 3.6 second shorter than thermopile power meters; under trigger measuring mode which enables the CMOS camera to synchronize with intermittent laser output, the average measuring error is less than 3%, and the shortest response time is 20 millisecond.

  5. ScriptingRT: A Software Library for Collecting Response Latencies in Online Studies of Cognition

    PubMed Central

    Schubert, Thomas W.; Murteira, Carla; Collins, Elizabeth C.; Lopes, Diniz

    2013-01-01

    ScriptingRT is a new open source tool to collect response latencies in online studies of human cognition. ScriptingRT studies run as Flash applets in enabled browsers. ScriptingRT provides the building blocks of response latency studies, which are then combined with generic Apache Flex programming. Six studies evaluate the performance of ScriptingRT empirically. Studies 1–3 use specialized hardware to measure variance of response time measurement and stimulus presentation timing. Studies 4–6 implement a Stroop paradigm and run it both online and in the laboratory, comparing ScriptingRT to other response latency software. Altogether, the studies show that Flash programs developed in ScriptingRT show a small lag and an increased variance in response latencies. However, this did not significantly influence measured effects: The Stroop effect was reliably replicated in all studies, and the found effects did not depend on the software used. We conclude that ScriptingRT can be used to test response latency effects online. PMID:23805326

  6. Microfossil measures of rapid sea-level rise: Timing of response of two microfossil groups to a sudden tidal-flooding experiment in Cascadia

    USGS Publications Warehouse

    Horton, B.P.; Milker, Yvonne; Dura, T.; Wang, Kelin; Bridgeland, W.T.; Brophy, Laura S.; Ewald, M.; Khan, Nicole; Engelhart, S.E.; Nelson, Alan R.; Witter, Robert C.

    2017-01-01

    Comparisons of pre-earthquake and post-earthquake microfossils in tidal sequences are accurate means to measure coastal subsidence during past subduction earthquakes, but the amount of subsidence is uncertain, because the response times of fossil taxa to coseismic relative sea-level (RSL) rise are unknown. We measured the response of diatoms and foraminifera to restoration of a salt marsh in southern Oregon, USA. Tidal flooding following dike removal caused an RSL rise of ∼1 m, as might occur by coseismic subsidence during momentum magnitude (Mw) 8.1–8.8 earthquakes on this section of the Cascadia subduction zone. Less than two weeks after dike removal, diatoms colonized low marsh and tidal flats in large numbers, showing that they can record seismically induced subsidence soon after earthquakes. In contrast, low-marsh foraminifera took at least 11 months to appear in sizeable numbers. Where subsidence measured with diatoms and foraminifera differs, their different response times may provide an estimate of postseismic vertical deformation in the months following past megathrust earthquakes.

  7. Assessment of a Rotating Time Sampling Procedure: Implications for Interobserver Agreement and Response Measurement

    ERIC Educational Resources Information Center

    Becraft, Jessica L.; Borrero, John C.; Davis, Barbara J.; Mendres-Smith, Amber E.

    2016-01-01

    The current study was designed to evaluate a rotating momentary time sampling (MTS) data collection system. A rotating MTS system has been used to measure activity preferences of preschoolers but not to collect data on responses that vary in duration and frequency (e.g., talking). We collected data on talking for 10 preschoolers using a 5-s MTS…

  8. REAL-TIME MEASUREMENT OF AIRWAY RESPONSES TO SULOFUR DIOXIDE (SO2) IN AN INTACT, AWAKE GUINEA PIG MODEL

    EPA Science Inventory

    Real-time measurment of airway responses to Sulfur Dioxide (SO2) in an intact, awake guinea pig model. J Stanek1,2, Q Krantz2, J Nolan2, D Winsett2, W Watkinson2, and D Costa2. 1College of Veterinary Medicine, NCSU, Raleigh, NC, USA; 2Pulmonary Toxicology Branch, ETD, NHEERL, US...

  9. Growth and characterization of high-performance photorefractive BaTiO3 crystals

    NASA Technical Reports Server (NTRS)

    Warde, C.; Garrett, M. H.; Chang, J. Y.; Jenssen, H. P.; Tuller, H. L.

    1991-01-01

    Barium titanate has been used for many nonlinear optical applications primarily because it has high grain and high self-pumped phase conjugate reflectivities. However, barium titanate has had a relatively slow response time, and thus low sensitivity. Therefore, it has not been suited to real-time operations. In this report we will describe the modifications in crystal growth, doping, reduction, and poling that have produced barium titanate crystals with the fastest photorefractive response time reported to date, approximately 21 microseconds with a beam-coupling gain coefficient of 38.7 cm(exp -1) and the highest sensitivity reported to date of 3.44 cm(exp 3)/kJ. The sensitivity of these barium titanate crystals is comparable to or greater than other photorefractive oxides. We will show, for the first time, beam-coupling in barium titanate at video frame rates. We infer from response time measurements that barium titanate has a phonon limited mobility. Also, photorefractive response time measurements as a function of the crystallographic orientation and grating wave vector for our cobalt-doped oxygen reduced crystals indicate that their faster response time arise because of an increase in the free carrier lifetime.

  10. Shock response of poly[methyl methacrylate] (PMMA) measured with embedded electromagnetic gauges

    NASA Astrophysics Data System (ADS)

    Lacina, David; Neel, Christopher; Dattelbaum, Dana

    2018-05-01

    The shock response of poly[methyl methacrylate] (PMMA) acquired from two providers, Spartech and Rohm & Haas, has been measured to investigate the shock response variations related to material pedigree. These measurements have also been used to examine the effects of viscoelasticity on Spartech PMMA. Measurements of the Hugoniot curves, release wave speeds, and index of refraction have been acquired up to previously unexplored stresses, ˜10.7 GPa, for Spartech PMMA. In-situ, time-resolved particle velocity wave profiles, as a function of time and depth, were obtained using twelve separate electromagnetic gauge elements embedded at different depths in the PMMA. A comparison of the new data to the shock response data for Rohm and Haas PMMA, used as a "standard" material in shock compression studies, shows that there are no significant differences in shock response for the two materials. From the index of refraction measurements, the apparent particle velocity correction for a PMMA window exhibits an interesting oscillation, increasing at up = 0.3 km/s after decreasing up to that point. The results are generalized into guidelines for sourcing PMMA for use in shock studies.

  11. Improving the Reliability of Student Scores from Speeded Assessments: An Illustration of Conditional Item Response Theory Using a Computer-Administered Measure of Vocabulary.

    PubMed

    Petscher, Yaacov; Mitchell, Alison M; Foorman, Barbara R

    2015-01-01

    A growing body of literature suggests that response latency, the amount of time it takes an individual to respond to an item, may be an important factor to consider when using assessment data to estimate the ability of an individual. Considering that tests of passage and list fluency are being adapted to a computer administration format, it is possible that accounting for individual differences in response times may be an increasingly feasible option to strengthen the precision of individual scores. The present research evaluated the differential reliability of scores when using classical test theory and item response theory as compared to a conditional item response model which includes response time as an item parameter. Results indicated that the precision of student ability scores increased by an average of 5 % when using the conditional item response model, with greater improvements for those who were average or high ability. Implications for measurement models of speeded assessments are discussed.

  12. Improving the Reliability of Student Scores from Speeded Assessments: An Illustration of Conditional Item Response Theory Using a Computer-Administered Measure of Vocabulary

    PubMed Central

    Petscher, Yaacov; Mitchell, Alison M.; Foorman, Barbara R.

    2016-01-01

    A growing body of literature suggests that response latency, the amount of time it takes an individual to respond to an item, may be an important factor to consider when using assessment data to estimate the ability of an individual. Considering that tests of passage and list fluency are being adapted to a computer administration format, it is possible that accounting for individual differences in response times may be an increasingly feasible option to strengthen the precision of individual scores. The present research evaluated the differential reliability of scores when using classical test theory and item response theory as compared to a conditional item response model which includes response time as an item parameter. Results indicated that the precision of student ability scores increased by an average of 5 % when using the conditional item response model, with greater improvements for those who were average or high ability. Implications for measurement models of speeded assessments are discussed. PMID:27721568

  13. Interdependency between Risk Assessments for Self and Other in the Field of Comparative Optimism: The Contribution of Response Times

    ERIC Educational Resources Information Center

    Spitzenstetter, Florence; Schimchowitsch, Sarah

    2012-01-01

    By introducing a response-time measure in the field of comparative optimism, this study was designed to explore how people estimate risk to self and others depending on the evaluation order (self/other or other/self). Our results show the interdependency between self and other answers. Indeed, while response time for risk assessment for the self…

  14. Development of Aeroservoelastic Analytical Models and Gust Load Alleviation Control Laws of a SensorCraft Wind-Tunnel Model Using Measured Data

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.; Vartio, Eric; Shimko, Anthony; Kvaternik, Raymond G.; Eure, Kenneth W.; Scott,Robert C.

    2007-01-01

    Aeroservoelastic (ASE) analytical models of a SensorCraft wind-tunnel model are generated using measured data. The data was acquired during the ASE wind-tunnel test of the HiLDA (High Lift-to-Drag Active) Wing model, tested in the NASA Langley Transonic Dynamics Tunnel (TDT) in late 2004. Two time-domain system identification techniques are applied to the development of the ASE analytical models: impulse response (IR) method and the Generalized Predictive Control (GPC) method. Using measured control surface inputs (frequency sweeps) and associated sensor responses, the IR method is used to extract corresponding input/output impulse response pairs. These impulse responses are then transformed into state-space models for use in ASE analyses. Similarly, the GPC method transforms measured random control surface inputs and associated sensor responses into an AutoRegressive with eXogenous input (ARX) model. The ARX model is then used to develop the gust load alleviation (GLA) control law. For the IR method, comparison of measured with simulated responses are presented to investigate the accuracy of the ASE analytical models developed. For the GPC method, comparison of simulated open-loop and closed-loop (GLA) time histories are presented.

  15. Development of Aeroservoelastic Analytical Models and Gust Load Alleviation Control Laws of a SensorCraft Wind-Tunnel Model Using Measured Data

    NASA Technical Reports Server (NTRS)

    Silva, Walter A.; Shimko, Anthony; Kvaternik, Raymond G.; Eure, Kenneth W.; Scott, Robert C.

    2006-01-01

    Aeroservoelastic (ASE) analytical models of a SensorCraft wind-tunnel model are generated using measured data. The data was acquired during the ASE wind-tunnel test of the HiLDA (High Lift-to-Drag Active) Wing model, tested in the NASA Langley Transonic Dynamics Tunnel (TDT) in late 2004. Two time-domain system identification techniques are applied to the development of the ASE analytical models: impulse response (IR) method and the Generalized Predictive Control (GPC) method. Using measured control surface inputs (frequency sweeps) and associated sensor responses, the IR method is used to extract corresponding input/output impulse response pairs. These impulse responses are then transformed into state-space models for use in ASE analyses. Similarly, the GPC method transforms measured random control surface inputs and associated sensor responses into an AutoRegressive with eXogenous input (ARX) model. The ARX model is then used to develop the gust load alleviation (GLA) control law. For the IR method, comparison of measured with simulated responses are presented to investigate the accuracy of the ASE analytical models developed. For the GPC method, comparison of simulated open-loop and closed-loop (GLA) time histories are presented.

  16. A Box-Cox normal model for response times.

    PubMed

    Klein Entink, R H; van der Linden, W J; Fox, J-P

    2009-11-01

    The log-transform has been a convenient choice in response time modelling on test items. However, motivated by a dataset of the Medical College Admission Test where the lognormal model violated the normality assumption, the possibilities of the broader class of Box-Cox transformations for response time modelling are investigated. After an introduction and an outline of a broader framework for analysing responses and response times simultaneously, the performance of a Box-Cox normal model for describing response times is investigated using simulation studies and a real data example. A transformation-invariant implementation of the deviance information criterium (DIC) is developed that allows for comparing model fit between models with different transformation parameters. Showing an enhanced description of the shape of the response time distributions, its application in an educational measurement context is discussed at length.

  17. Recovery cycle times of inferior colliculus neurons in the awake bat measured with spike counts and latencies

    PubMed Central

    Sayegh, Riziq; Aubie, Brandon; Fazel-Pour, Siavosh; Faure, Paul A.

    2012-01-01

    Neural responses in the mammalian auditory midbrain (inferior colliculus; IC) arise from complex interactions of synaptic excitation, inhibition, and intrinsic properties of the cell. Temporally selective duration-tuned neurons (DTNs) in the IC are hypothesized to arise through the convergence of excitatory and inhibitory synaptic inputs offset in time. Synaptic inhibition can be inferred from extracellular recordings by presenting pairs of pulses (paired tone stimulation) and comparing the evoked responses of the cell to each pulse. We obtained single unit recordings from the IC of the awake big brown bat (Eptesicus fuscus) and used paired tone stimulation to measure the recovery cycle times of DTNs and non-temporally selective auditory neurons. By systematically varying the interpulse interval (IPI) of the paired tone stimulus, we determined the minimum IPI required for a neuron's spike count or its spike latency (first- or last-spike latency) in response to the second tone to recover to within ≥50% of the cell's baseline count or to within 1 SD of it's baseline latency in response to the first tone. Recovery times of shortpass DTNs were significantly shorter than those of bandpass DTNs, and recovery times of bandpass DTNs were longer than allpass neurons not selective for stimulus duration. Recovery times measured with spike counts were positively correlated with those measured with spike latencies. Recovery times were also correlated with first-spike latency (FSL). These findings, combined with previous studies on duration tuning in the IC, suggest that persistent inhibition is a defining characteristic of DTNs. Herein, we discuss measuring recovery times of neurons with spike counts and latencies. We also highlight how persistent inhibition could determine neural recovery times and serve as a potential mechanism underlying the precedence effect in humans. Finally, we explore implications of recovery times for DTNs in the context of bat hearing and echolocation. PMID:22933992

  18. Does the rising placebo response impact antihypertensive clinical trial outcomes? An analysis of data from the Food and Drug Administration 1990-2016

    PubMed Central

    Fahl Mar, Kaysee; Schilling, Joshua; Brown, Walter A.

    2018-01-01

    Background Recent studies show that placebo response has grown significantly over time in clinical trials for antidepressants, ADHD medications, antiepileptics, and antidiabetics. Contrary to expectations, trial outcome measures and success rates have not been impacted. This study aimed to see if this trend of increasing placebo response and stable efficacy outcome measures is unique to the conditions previously studied or if it occurs in trials for conditions with physiologically-measured symptoms, such as hypertension. Method For this reason, we evaluated the efficacy data reported in the US Food and Drug Administration Medical and Statistical reviews for 23 antihypertensive programs (32,022 patients, 63 trials, 142 treatment arms). Placebo and medication response, effect sizes, and drug-placebo differences were calculated for each treatment arm and examined over time using meta-regression. We also explored the relationship of sample size, trial duration, baseline blood pressure, and number of treatment arms to placebo/drug response and efficacy outcome measures. Results Like trials of other conditions, placebo response has risen significantly over time (R2 = 0.093, p = 0.018) and effect size (R2 = 0.013, p = 0.187) drug-placebo difference (R2 = 0.013, p = 0.182) and success rate (134/142, 94.4%) have remained unaffected, likely due to a significant compensatory increase in antihypertensive response (R2 = 0.086, p<0.001). Treatment arms are likely overpowered with sample sizes increasing over time (R2 = 0.387, p<0.0001) and stable, large effect sizes (0.78 ±0.37). The exploratory analysis of sample size, trial duration, baseline blood pressure, and number of treatment arms yielded mixed results unlikely to explain the pattern of placebo response and efficacy outcomes over time. The magnitude of placebo response had no relationship to effect size (p = 0.877), antihypertensive-placebo differences (p = 0.752), or p-values (p = 0.963) but was correlated with antihypertensive response (R2 = 0.347, p<0.0001). Conclusions As hypothesized, this study shows that placebo response is increasing in clinical trials for hypertension without any evidence of this increase impacting trial outcomes. Attempting to control placebo response in clinical trials for hypertension may not be necessary for successful efficacy outcomes. In exploratory analysis, we noted that despite finding significant relationships, none of the trial or patient characteristics we examined offered a clear explanation of the rise in placebo and stability in outcome measures over time. Collectively, these data suggest that the phenomenon of increasing placebo response and stable efficacy outcomes may be a general trend, occurring across trials for various psychiatric and medical conditions with physiological and non-physiological endpoints. PMID:29489874

  19. The Assessment of Protective Behavioral Strategies: Comparing the Absolute Frequency and Contingent Frequency Response Scales

    PubMed Central

    Kite, Benjamin A.; Pearson, Matthew R.; Henson, James M.

    2016-01-01

    The purpose of the present studies was to examine the effects of response scale on the observed relationships between protective behavioral strategies (PBS) measures and alcohol-related outcomes. We reasoned that an ‘absolute frequency’ scale (stem: “how many times…”; response scale: 0 times to 11+ times) conflates the frequency of using PBS with the frequency of consuming alcohol; thus, we hypothesized that the use of an absolute frequency response scale would result in positive relationships between types of PBS and alcohol-related outcomes. Alternatively, a ‘contingent frequency’ scale (stem: “When drinking…how often…”; response scale: never to always) does not conflate frequency of alcohol use with use of PBS; therefore, we hypothesized that use of a contingent frequency scale would result in negative relationships between use of PBS and alcohol-related outcomes. Two published measures of PBS were used across studies: the Protective Behavioral Strategies Survey (PBSS) and the Strategy Questionnaire (SQ). Across three studies, we demonstrate that when measured using a contingent frequency response scale, PBS measures relate negatively to alcohol-related outcomes in a theoretically consistent manner; however, when PBS measures were measured on an absolute frequency response scale, they were non-significantly or positively related to alcohol-related outcomes. We discuss the implications of these findings for the assessment of PBS. PMID:23438243

  20. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.; Taylor, Bryant D.; Shams, Qamar A.; Fox, Robert L.

    2005-01-01

    A measurement acquisition method that alleviates many shortcomings of traditional measurement systems is presented in this paper. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed.

  1. Light beam range finder

    DOEpatents

    McEwan, Thomas E.

    1998-01-01

    A "laser tape measure" for measuring distance which includes a transmitter such as a laser diode which transmits a sequence of electromagnetic pulses in response to a transmit timing signal. A receiver samples reflections from objects within the field of the sequence of visible electromagnetic pulses with controlled timing, in response to a receive timing signal. The receiver generates a sample signal in response to the samples which indicates distance to the object causing the reflections. The timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the reflection such that the time between transmission of pulses in the sequence in sampling by the receiver sweeps over a range of delays. The transmit timing signal causes the transmitter to transmit the sequence of electromagnetic pulses at a pulse repetition rate, and the received timing signal sweeps over the range of delays in a sweep cycle such that reflections are sampled at the pulse repetition rate and with different delays in the range of delays, such that the sample signal represents received reflections in equivalent time. The receiver according to one aspect of the invention includes an avalanche photodiode and a sampling gate coupled to the photodiode which is responsive to the received timing signal. The transmitter includes a laser diode which supplies a sequence of visible electromagnetic pulses. A bright spot projected on to the target clearly indicates the point that is being measured, and the user can read the range to that point with precision of better than 0.1%.

  2. Light beam range finder

    DOEpatents

    McEwan, T.E.

    1998-06-16

    A ``laser tape measure`` for measuring distance is disclosed which includes a transmitter such as a laser diode which transmits a sequence of electromagnetic pulses in response to a transmit timing signal. A receiver samples reflections from objects within the field of the sequence of visible electromagnetic pulses with controlled timing, in response to a receive timing signal. The receiver generates a sample signal in response to the samples which indicates distance to the object causing the reflections. The timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the reflection such that the time between transmission of pulses in the sequence in sampling by the receiver sweeps over a range of delays. The transmit timing signal causes the transmitter to transmit the sequence of electromagnetic pulses at a pulse repetition rate, and the received timing signal sweeps over the range of delays in a sweep cycle such that reflections are sampled at the pulse repetition rate and with different delays in the range of delays, such that the sample signal represents received reflections in equivalent time. The receiver according to one aspect of the invention includes an avalanche photodiode and a sampling gate coupled to the photodiode which is responsive to the received timing signal. The transmitter includes a laser diode which supplies a sequence of visible electromagnetic pulses. A bright spot projected on to the target clearly indicates the point that is being measured, and the user can read the range to that point with precision of better than 0.1%. 7 figs.

  3. Time-frequency analysis of functional optical mammographic images

    NASA Astrophysics Data System (ADS)

    Barbour, Randall L.; Graber, Harry L.; Schmitz, Christoph H.; Tarantini, Frank; Khoury, Georges; Naar, David J.; Panetta, Thomas F.; Lewis, Theophilus; Pei, Yaling

    2003-07-01

    We have introduced working technology that provides for time-series imaging of the hemoglobin signal in large tissue structures. In this study we have explored our ability to detect aberrant time-frequency responses of breast vasculature for subjects with Stage II breast cancer at rest and in response to simple provocations. The hypothesis being explored is that time-series imaging will be sensitive to the known structural and functional malformations of the tumor vasculature. Mammographic studies were conducted using an adjustable hemisheric measuring head containing 21 source and 21 detector locations (441 source-detector pairs). Simultaneous dual-wavelength studies were performed at 760 and 830 nm at a framing rate of ~2.7 Hz. Optical measures were performed on women lying prone with the breast hanging in a pendant position. Two class of measures were performed: (1) 20- minute baseline measure wherein the subject was at rest; (2) provocation studies wherein the subject was asked to perform some simple breathing maneuvers. Collected data were analyzed to identify the time-frequency structure and central tendencies of the detector responses and those of the image time series. Imaging data were generated using the Normalized Difference Method (Pei et al., Appl. Opt. 40, 5755-5769, 2001). Results obtained clearly document three classes of anomalies when compared to the normal contralateral breast. 1) Breast tumors exhibit altered oxygen supply/demand imbalance in response to an oxidative challenge (breath hold). 2) The vasomotor response of the tumor vasculature is mainly depressed and exhibits an altered modulation. 3) The affected area of the breast wherein the altered vasomotor signature is seen extends well beyond the limits of the tumor itself.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manouchehrian, M.; Larijani, M.M., E-mail: mmojtahedfr@yahooo.com; Elahi, S.M.

    Highlights: • Tellurium thin films were prepared by thermal evaporation technique. • Tellurium thin films showed excellent gas-sensing properties to H{sub 2}S at room temperature. • Tellurium showed a remarkably enhanced response to H{sub 2}S gas under UV irradiation. • The reason of the enhanced response by UV irradiation was discussed. - Abstract: In this research, tellurium thin films were investigated for use as hydrogen sulfide gas sensors. To this end, a tellurium thin film has been deposited on Al{sub 2}O{sub 3} substrates by thermal evaporation, and the influence of thickness on the sensitivity of the tellurium thin film formore » measuring H{sub 2}S gas is studied. XRD patterns indicate that as the thickness increases, the crystallization improves. Observing the images obtained by SEM, it is seen that the grain size increases as the thickness increases. Studying the effect of thickness on H{sub 2}S gas measurement, it became obvious that as the thickness increases, the sensitivity decreases and the response and recovery times increase. To improve the response and recovery times of the tellurium thin film for measuring H{sub 2}S gas, the influence of UV radiation while measuring H{sub 2}S gas was also investigated. The results indicate that the response and recovery times strongly decrease using UV radiation.« less

  5. Response trajectories reveal conflict phase in image-word mismatch.

    PubMed

    van Vugt, Floris T; Cavanagh, Patrick

    2012-02-01

    In the present study, response trajectories were used in a picture–word conflict task to determine the timing of intermediate processing stages that are relatively inaccessible to response time measures. A marker was placed above or below the word ABOVE or BELOW so that its location was congruent or in conflict with the word's meaning. To report either word location(above or below the marker) or word meaning, participants moved a mouse upward toward the appropriate top left or right answer corner on the display screen.Their response trajectories showed a number of distinctive features: First, at about 200 ms after stimulus onset(the "decision moment"), the trajectory abruptly began to arc toward the appropriate answer corner; second,when the word's meaning and position were in conflict,the trajectory showed an interruption that continued until the conflict was resolved. By varying the SOA of the word and marker onsets, we found that the word meaning and word position became available at approximately 325 ms and 251 ms, respectively, after their onsets, and that the delay to resolve conflicts was about 138 ms. The timing of these response trajectory events was more stable than any extracted from the final response times, demonstrating the power of response trajectories to reveal processing stages that are only poorly resolved, if at all, by response time measures [added].

  6. Breaking Out of the Lab: Measuring Real-Time Responses to Televised Political Content in Real-World Settings.

    PubMed

    Maier, Jürgen; Hampe, J Felix; Jahn, Nico

    2016-01-01

    Real-time response (RTR) measurement is an important technique for analyzing human processing of electronic media stimuli. Although it has been demonstrated that RTR data are reliable and internally valid, some argue that they lack external validity. The reason for this is that RTR measurement is restricted to a laboratory environment due to its technical requirements. This paper introduces a smartphone app that 1) captures real-time responses using the dial technique and 2) provides a solution for one of the most important problems in RTR measurement, the (automatic) synchronization of RTR data. In addition, it explores the reliability and validity of mobile RTR measurement by comparing the real-time reactions of two samples of young and well-educated voters to the 2013 German televised debate. Whereas the first sample participated in a classical laboratory study, the second sample was equipped with our mobile RTR system and watched the debate at home. Results indicate that the mobile RTR system yields similar results to the lab-based RTR measurement, providing evidence that laboratory studies using RTR are externally valid. In particular, the argument that the artificial reception situation creates artificial results has to be questioned. In addition, we conclude that RTR measurement outside the lab is possible. Hence, mobile RTR opens the door for large-scale studies to better understand the processing and impact of electronic media content.

  7. Response of captive, breeding mallards to oiled water

    USGS Publications Warehouse

    Custer, T.W.; Albers, P.H.

    1980-01-01

    Behavioral response of mallard ducks to Prudhoe Bay crude oil slicks on water basins. Water basins were oiled with either 5 or 100 ul of oil and monitored with time-lapse cameras for 24 hr before and after water treatment. Measured time of first entry and amount of time spent on the water.

  8. Time-lapse and slow-motion tracking of temperature changes: response time of a thermometer

    NASA Astrophysics Data System (ADS)

    Moggio, L.; Onorato, P.; Gratton, L. M.; Oss, S.

    2017-03-01

    We propose the use of a smartphone based time-lapse and slow-motion video techniques together with tracking analysis as valuable tools for investigating thermal processes such as the response time of a thermometer. The two simple experimental activities presented here, suitable also for high school and undergraduate students, allow one to measure in a simple yet rigorous way the response time of an alcohol thermometer and show its critical dependence on the properties of the surrounding environment giving insight into instrument characteristics, heat transfer and thermal equilibrium concepts.

  9. A Multivariate Multilevel Approach to the Modeling of Accuracy and Speed of Test Takers

    ERIC Educational Resources Information Center

    Klein Entink, R. H.; Fox, J. P.; van der Linden, W. J.

    2009-01-01

    Response times on test items are easily collected in modern computerized testing. When collecting both (binary) responses and (continuous) response times on test items, it is possible to measure the accuracy and speed of test takers. To study the relationships between these two constructs, the model is extended with a multivariate multilevel…

  10. Time-dependent compressibility of poly (methyl methacrylate) (PMMA) : an experimental and molecular dynamics investigation

    NASA Astrophysics Data System (ADS)

    Sane, Sandeep Bhalchandra

    This thesis contains three chapters, which describe different aspects of an investigation of the bulk response of Poly(Methyl Methacrylate) (PMMA). The first chapter describes the physical measurements by means of a Belcher/McKinney-type apparatus. Used earlier for the measurement of the bulk response of Poly(Vinyl Acetate), it was now adapted for making measurements at higher temperatures commensurate with the glass transition temperature of PMMA. The dynamic bulk compliance of PMMA was measured at atmospheric pressure over a wide range of temperatures and frequencies, from which the master curves for the bulk compliance were generated by means of the time-temperature superposition principle. It was found that the extent of the transition ranges for the bulk and shear response were comparable. Comparison of the shift factors for bulk and shear responses supports the idea that different molecular mechanisms contribute to shear and bulk deformations. The second chapter delineates molecular dynamics computations for the bulk response for a range of pressures and temperatures. The model(s) consisted of 2256 atoms formed into three polymer chains with fifty monomer units per chain per unit cell. The time scales accessed were limited to tens of pico seconds. It was found that, in addition to the typical energy minimization and temperature annealing cycles for establishing equilibrium models, it is advantageous to subject the model samples to a cycle of relatively large pressures (GPa-range) for improving the equilibrium state. On comparing the computations with the experimentally determined "glassy" behavior, one finds that, although the computations were limited to small samples in a physical sense, the primary limitation rests in the very short times (pico seconds). The molecular dynamics computations do not model the physically observed temperature sensitivity of PMMA, even if one employs a hypothetical time-temperature shift to account for the large difference in time scales between experiment and computation. The values computed by the molecular dynamics method do agree with the values measured at the coldest temperature and at the highest frequency of one kiloHertz. The third chapter draws on measurements of uniaxial, shear and Poisson response conducted previously in our laboratory. With the availability of four time or frequency-dependent material functions for the same material, the process of interconversion between different material functions was investigated. Computed material functions were evaluated against the direct experimental measurements and the limitations imposed on successful interconversion due to the experimental errors in the underlying physical data were explored. Differences were observed that are larger than the experimental errors would suggest.

  11. Continuous performance task in ADHD: Is reaction time variability a key measure?

    PubMed

    Levy, Florence; Pipingas, Andrew; Harris, Elizabeth V; Farrow, Maree; Silberstein, Richard B

    2018-01-01

    To compare the use of the Continuous Performance Task (CPT) reaction time variability (intraindividual variability or standard deviation of reaction time), as a measure of vigilance in attention-deficit hyperactivity disorder (ADHD), and stimulant medication response, utilizing a simple CPT X-task vs an A-X-task. Comparative analyses of two separate X-task vs A-X-task data sets, and subgroup analyses of performance on and off medication were conducted. The CPT X-task reaction time variability had a direct relationship to ADHD clinician severity ratings, unlike the CPT A-X-task. Variability in X-task performance was reduced by medication compared with the children's unmedicated performance, but this effect did not reach significance. When the coefficient of variation was applied, severity measures and medication response were significant for the X-task, but not for the A-X-task. The CPT-X-task is a useful clinical screening test for ADHD and medication response. In particular, reaction time variability is related to default mode interference. The A-X-task is less useful in this regard.

  12. Visual motor response of crewmen during a simulated 90 day space mission as measured by the critical task battery

    NASA Technical Reports Server (NTRS)

    Allen, R. W.; Jex, H. R.

    1972-01-01

    In order to test various components of a regenerative life support system and to obtain data on the physiological and psychological effects of long-duration exposure to confinement in a space station atmosphere, four carefully screened young men were sealed in space station simulator for 90 days. A tracking test battery was administered during the above experiment. The battery included a clinical test (critical instability task) related to the subject's dynamic time delay, and a conventional steady tracking task, during which dynamic response (describing functions) and performance measures were obtained. Good correlation was noted between the clinical critical instability scores and more detailed tracking parameters such as dynamic time delay and gain-crossover frequency. The comprehensive data base on human operator tracking behavior obtained in this study demonstrate that sophisticated visual-motor response properties can be efficiently and reliably measured over extended periods of time.

  13. The Stability of Perceived Pubertal Timing across Adolescence

    PubMed Central

    Cance, Jessica Duncan; Ennett, Susan T.; Morgan-Lopez, Antonio A.; Foshee, Vangie A.

    2011-01-01

    It is unknown whether perceived pubertal timing changes as puberty progresses or whether it is an important component of adolescent identity formation that is fixed early in pubertal development. The purpose of this study is to examine the stability of perceived pubertal timing among a school-based sample of rural adolescents aged 11 to 17 (N=6,425; 50% female; 53% White). Two measures of pubertal timing were used, stage-normative, based on the Pubertal Development Scale, a self-report scale of secondary sexual characteristics, and peer-normative, a one-item measure of perceived pubertal timing. Two longitudinal methods were used: one-way random effects ANOVA models and latent class analysis. When calculating intraclass correlation coefficients using the one-way random effects ANOVA models, which is based on the average reliability from one time point to the next, both measures had similar, but poor, stability. In contrast, latent class analysis, which looks at the longitudinal response pattern of each individual and treats deviation from that pattern as measurement error, showed three stable and distinct response patterns for both measures: always early, always on-time, and always late. Study results suggest instability in perceived pubertal timing from one age to the next, but this instability is likely due to measurement error. Thus, it may be necessary to take into account the longitudinal pattern of perceived pubertal timing across adolescence rather than measuring perceived pubertal timing at one point in time. PMID:21983873

  14. Femtosecond timing measurement and control using ultrafast organic thin films

    NASA Astrophysics Data System (ADS)

    Naruse, Makoto; Mitsu, Hiroyuki; Furuki, Makoto; Iwasa, Izumi; Sato, Yasuhiro; Tatsuura, Satoshi; Tian, Minquan

    2003-12-01

    We show a femtosecond timing measurement and control technique using a squarylium dye J-aggregate film, which is an organic thin film that acts as an ultrafast two-dimensional optical switch. Optical pulse timing is directly mapped to space-domain position on the film, and the large area and ultrafast response offer a femtosecond-resolved, large dynamic range, real-time, multichannel timing measurement capability. A timing fluctuation (jitter, wander, and skew) reduction architecture is presented and experimentally demonstrated.

  15. Ambulant Measurements of Physiological Status and Cognitive Performance during Sustained Operations

    DTIC Science & Technology

    2009-10-01

    the target, reaction time, illegal responses, and missed responses were recorded. 2.4 Physiological measurements 2.4.1 Anthropometry ...system (SPi-Elite, GPsports Australia ) was mounted on the soldiers’ backpack. The system measured continuously during the training weeks. Walking or...the percentage missed stimuli were even more alike. 3.3 Physiological measurements 3.3.1 Anthropometry The soldiers who completed the training

  16. Comparing capacity coefficient and dual task assessment of visual multitasking workload

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blaha, Leslie M.

    Capacity coefficient analysis could offer a theoretically grounded alternative approach to subjective measures and dual task assessment of cognitive workload. Workload capacity or workload efficiency is a human information processing modeling construct defined as the amount of information that can be processed by the visual cognitive system given a specified of amount of time. In this paper, I explore the relationship between capacity coefficient analysis of workload efficiency and dual task response time measures. To capture multitasking performance, I examine how the relatively simple assumptions underlying the capacity construct generalize beyond the single visual decision making tasks. The fundamental toolsmore » for measuring workload efficiency are the integrated hazard and reverse hazard functions of response times, which are defined by log transforms of the response time distribution. These functions are used in the capacity coefficient analysis to provide a functional assessment of the amount of work completed by the cognitive system over the entire range of response times. For the study of visual multitasking, capacity coefficient analysis enables a comparison of visual information throughput as the number of tasks increases from one to two to any number of simultaneous tasks. I illustrate the use of capacity coefficients for visual multitasking on sample data from dynamic multitasking in the modified Multi-attribute Task Battery.« less

  17. UAS Integration into the NAS: iHTL: DAA Display Evaluation Preliminary Results

    NASA Technical Reports Server (NTRS)

    Fern, Lisa; Rorie, Conrad; Shively, Jay

    2014-01-01

    The integrated human-in-the-loop (iHITL) simulation examined the effect of four different Detect-and-Avoid (DAA) display concepts on unmanned aircraft system (UAS) pilots' ability to maintain safe separation. The displays varied in the type and amount of guidance they provided to pilots. The study's background and methodology are discussed, followed by a presentation of the preliminary 'measured response' data (i.e., pilots' end-to-end response time in reacting to traffic alerts on their DAA display). Results indicate that display type had moderate to no affect on pilot measured response times.

  18. Estimation of automobile-driver describing function from highway tests using the double steering wheel

    NASA Technical Reports Server (NTRS)

    Delp, P.; Crossman, E. R. F. W.; Szostak, H.

    1972-01-01

    The automobile-driver describing function for lateral position control was estimated for three subjects from frequency response analysis of straight road test results. The measurement procedure employed an instrumented full size sedan with known steering response characteristics, and equipped with a lateral lane position measuring device based on video detection of white stripe lane markings. Forcing functions were inserted through a servo driven double steering wheel coupling the driver to the steering system proper. Random appearing, Gaussian, and transient time functions were used. The quasi-linear models fitted to the random appearing input frequency response characterized the driver as compensating for lateral position error in a proportional, derivative, and integral manner. Similar parameters were fitted to the Gabor transformed frequency response of the driver to transient functions. A fourth term corresponding to response to lateral acceleration was determined by matching the time response histories of the model to the experimental results. The time histories show evidence of pulse-like nonlinear behavior during extended response to step transients which appear as high frequency remnant power.

  19. Damage detection and quantification in a structural model under seismic excitation using time-frequency analysis

    NASA Astrophysics Data System (ADS)

    Chan, Chun-Kai; Loh, Chin-Hsiung; Wu, Tzu-Hsiu

    2015-04-01

    In civil engineering, health monitoring and damage detection are typically carry out by using a large amount of sensors. Typically, most methods require global measurements to extract the properties of the structure. However, some sensors, like LVDT, cannot be used due to in situ limitation so that the global deformation remains unknown. An experiment is used to demonstrate the proposed algorithms: a one-story 2-bay reinforce concrete frame under weak and strong seismic excitation. In this paper signal processing techniques and nonlinear identification are used and applied to the response measurements of seismic response of reinforced concrete structures subject to different level of earthquake excitations. Both modal-based and signal-based system identification and feature extraction techniques are used to study the nonlinear inelastic response of RC frame using both input and output response data or output only measurement. From the signal-based damage identification method, which include the enhancement of time-frequency analysis of acceleration responses and the estimation of permanent deformation using directly from acceleration response data. Finally, local deformation measurement from dense optical tractor is also use to quantify the damage of the RC frame structure.

  20. Mixing times in a stirred vessel with a modified turbine.

    PubMed

    Bombač, Andrej; Beader, Dečan; Zun, Iztok

    2012-12-01

    We present a mixing-time analysis for a double-disk turbine (DDT, SI Pat.No. 22243) and the well-known Rushton turbine (RuT) based on liquid stirring in a baffled vessel. The mixing time was measured locally based on the pulse/response technique. A small quantity of hot water, poured into the liquid bulk, just above the measurement location, was used as the pulse, while the change in the liquid temperature represented the system response. The results were obtained in two ways: (i) from measurements on the set-up and (ii) based on a CFD analysis. The pouring of the hot water was numerically simulated through the initialization of the scalar field. The duration of the temperature-pulse initialization around the measuring location corresponded to the pouring time in the experiment. All the energy introduced was freely swept away by the flow. The CFD-analyzed mixing times were consistently higher than the measured ones across the whole testing range, from 150 to 460 min-1. When comparing our mixing-time results with those from the literature based on a dimensionless mixing time we found them to be in good agreement.

  1. Cardiovascular, electrodermal, and respiratory response patterns to fear- and sadness-inducing films.

    PubMed

    Kreibig, Sylvia D; Wilhelm, Frank H; Roth, Walton T; Gross, James J

    2007-09-01

    Responses to fear- and sadness-inducing films were assessed using a broad range of cardiovascular (heart rate, T-wave amplitude, low- and high-frequency heart rate variability, stroke volume, preejection period, left-ventricular ejection time, Heather index, blood pressure, pulse amplitude and transit time, and finger temperature), electrodermal (level, response rate, and response amplitude), and respiratory (rate, tidal volume and its variability, inspiratory flow rate, duty cycle, and end-tidal pCO(2)) measures. Subjective emotional experience and facial behavior (Corrugator Supercilii and Zygomaticus Major EMG) served as control measures. Results indicated robust differential physiological response patterns for fear, sadness, and neutral (mean classification accuracy 85%). Findings are discussed in terms of the fight-flight and conservation-withdrawal responses and possible limitations of a valence-arousal categorization of emotion in affective space.

  2. Response variables for evaluation of the effectiveness of conservation corridors.

    PubMed

    Gregory, Andrew J; Beier, Paul

    2014-06-01

    Many studies have evaluated effectiveness of corridors by measuring species presence in and movement through small structural corridors. However, few studies have assessed whether these response variables are adequate for assessing whether the conservation goals of the corridors have been achieved or considered the costs or lag times involved in measuring the response variables. We examined 4 response variables-presence of the focal species in the corridor, interpatch movement via the corridor, gene flow, and patch occupancy--with respect to 3 criteria--relevance to conservation goals, lag time (fewest generations at which a positive response to the corridor might be evident with a particular variable), and the cost of a study when applying a particular variable. The presence variable had the least relevance to conservation goals, no lag time advantage compared with interpatch movement, and only a moderate cost advantage over interpatch movement or gene flow. Movement of individual animals between patches was the most appropriate response variable for a corridor intended to provide seasonal migration, but it was not an appropriate response variable for corridor dwellers, and for passage species it was only moderately relevant to the goals of gene flow, demographic rescue, and recolonization. Response variables related to gene flow provided a good trade-off among cost, relevance to conservation goals, and lag time. Nonetheless, the lag time of 10-20 generations means that evaluation of conservation corridors cannot occur until a few decades after a corridor has been established. Response variables related to occupancy were most relevant to conservation goals, but the lag time and costs to detect corridor effects on occupancy were much greater than the lag time and costs to detect corridor effects on gene flow. © 2014 Society for Conservation Biology.

  3. Experimental investigation of stress-inducing properties of system response times.

    PubMed

    Kuhmann, W

    1989-03-01

    System response times are regarded as a major stressor in human-computer interaction. In two earlier studies short (2s) and long (8s) response times were found to have differential effects on psychological, subjective, and performance variables, but results did not favour either response time. Therefore, in another laboratory study with 48 subjects in four independent groups working at a stimulated computer workplace, system response times of 2, 4, 6 and 8s were introduced in the same error detection task as used before, during 3 training and 5 working trials of 20 min each, and the same physiological, subjective and performance measures were obtained. There were no global effects on physiological variables, possibly due to low work load as a result of missing time pressure, but subjective and performance variables clearly favoured the longer system response times. When task periods and response time-periods were analysed separately, a shift of electrodermal activity could be observed from task- to response time-periods during the course of trials in the 8s condition. This did not appear in any other condition, which points to psychophysiological excitement that develops when system response times are too long, thus providing support for the concept of optimal system response times.

  4. Method and apparatus for the measurement of signals from radiation sensors

    DOEpatents

    De Geronimo, Gianluigi

    2012-09-18

    The preferred embodiments of the present invention include a device for measuring an ionizing event in a radiation sensor. The device can include a charge amplifier and a timing shaper. The charge amplifier receives a cathode signal and is configured to output an amplified cathode signal. The timing shaper is operatively connected to the charge amplifier to receive the amplified cathode signal. The timing shaper is configured to generate a first pulse in response to a beginning of the ionizing event and a second pulse in response to an end of the ionizing event. The first and second pulses are associated with a depth of interaction of the ionizing event and are generated in response to a slope of the amplified cathode signal changing.

  5. A Common Fluence Threshold for First Positive and Second Positive Phototropism in Arabidopsis thaliana1

    PubMed Central

    Janoudi, Abdul; Poff, Kenneth L.

    1990-01-01

    The relationship between the amount of light and the amount of response for any photobiological process can be based on the number of incident quanta per unit time (fluence rate-response) or on the number of incident quanta during a given period of irradiation (fluence-response). Fluence-response and fluence rate-response relationships have been measured for second positive phototropism by seedlings of Arabidopsis thaliana. The fluence-response relationships exhibit a single limiting threshold at about 0.01 micromole per square meter when measured at fluence rates from 2.4 × 10−5 to 6.5 × 10−3 micromoles per square meter per second. The threshold values in the fluence rateresponse curves decrease with increasing time of irradiation, but show a common fluence threshold at about 0.01 micromole per square meter. These thresholds are the same as the threshold of about 0.01 micromole per square meter measured for first positive phototropism. Based on these data, it is suggested that second positive curvature has a threshold in time of about 10 minutes. Moreover, if the times of irradiation exceed the time threshold, there is a single limiting fluence threshold at about 0.01 micromole per square meter. Thus, the limiting fluence threshold for second positive phototropism is the same as the fluence threshold for first positive phototropism. Based on these data, we suggest that this common fluence threshold for first positive and second positive phototropism is set by a single photoreceptor pigment system. PMID:11537470

  6. Response Time as an Indicator of Test Taker Speed: Assumptions Meet Reality

    ERIC Educational Resources Information Center

    Wise, Steven L.

    2015-01-01

    The growing presence of computer-based testing has brought with it the capability to routinely capture the time that test takers spend on individual test items. This, in turn, has led to an increased interest in potential applications of response time in measuring intellectual ability and achievement. Goldhammer (this issue) provides a very useful…

  7. Response of Vibrio fischeri to repeated exposures over time in an Online Toxicity Monitor

    EPA Science Inventory

    Online Toxicity Monitors have been developed to provide continuous, time-relevant information regarding water quality. These systems measure a physiological or behavioral response of a sentinel organism to changes water quality. One such system, the Microlan Toxcontrol, is base...

  8. Response time scores on a reflexive attention task predict a child's inattention score from a parent report.

    PubMed

    Lundwall, Rebecca A; Sgro, Jordan F; Fanger, Julia

    2018-01-01

    Compared to sustained attention, only a small proportion of studies examine reflexive attention as a component of everyday attention. Understanding the significance of reflexive attention to everyday attention may inform better treatments for attentional disorders. Children from a general population (recruited when they were from 9-16 years old) completed an exogenously-cued task measuring the extent to which attention is captured by peripheral cue-target conditions. Parents completed a questionnaire reporting their child's day-to-day attention. A general linear model indicated that parent-rated inattention predicted the increase in response time over baseline when a bright cue preceded the target (whether it was valid or invalid) but not when a dim cue preceded the target. More attentive children had more pronounced response time increases from baseline. Our findings suggest a link between a basic measure of cognition (response time difference scores) and parent observations. The findings have implications for increased understanding of the role of reflexive attention in the everyday attention of children.

  9. Effect of processing time delay on the dose response of Kodak EDR2 film.

    PubMed

    Childress, Nathan L; Rosen, Isaac I

    2004-08-01

    Kodak EDR2 film is a widely used two-dimensional dosimeter for intensity modulated radiotherapy (IMRT) measurements. Our clinical use of EDR2 film for IMRT verifications revealed variations and uncertainties in dose response that were larger than expected, given that we perform film calibrations for every experimental measurement. We found that the length of time between film exposure and processing can affect the absolute dose response of EDR2 film by as much as 4%-6%. EDR2 films were exposed to 300 cGy using 6 and 18 MV 10 x 10 cm2 fields and then processed after time delays ranging from 2 min to 24 h. An ion chamber measured the relative dose for these film exposures. The ratio of optical density (OD) to dose stabilized after 3 h. Compared to its stable value, the film response was 4%-6% lower at 2 min and 1% lower at 1 h. The results of the 4 min and 1 h processing time delays were verified with a total of four different EDR2 film batches. The OD/dose response for XV2 films was consistent for time periods of 4 min and 1 h between exposure and processing. To investigate possible interactions of the processing time delay effect with dose, single EDR2 films were irradiated to eight different dose levels between 45 and 330 cGy using smaller 3 x 3 cm2 areas. These films were processed after time delays of 1, 3, and 6 h, using 6 and 18 MV photon qualities. The results at all dose levels were consistent, indicating that there is no change in the processing time delay effect for different doses. The difference in the time delay effect between the 6 and 18 MV measurements was negligible for all experiments. To rule out bias in selecting film regions for OD measurement, we compared the use of a specialized algorithm that systematically determines regions of interest inside the 10 x 10 cm2 exposure areas to manually selected regions of interest. There was a maximum difference of only 0.07% between the manually and automatically selected regions, indicating that the use of a systematic algorithm to determine regions of interest in large and fairly uniform areas is not necessary. Based on these results, we recommend a minimum time of 1 h between exposure and processing for all EDR2 film measurements.

  10. Flexible and inflexible response components: a Stroop study with typewritten output.

    PubMed

    Damian, Markus F; Freeman, Norman H

    2008-05-01

    Two experiments were directed at investigating the relationship between response selection and execution in typewriting, and specifically the extent to which concurrent processing takes place. In a Stroop paradigm adapted from [Logan, G. D., & Zbrodoff, N. J. (1998). Stroop-type interference: Congruity effects in colour naming with typewritten responses. Journal of Experimental Psychology: Human Perception and Performance, 24, 978-992], participants typed the names of colour patches with incongruent, congruent, or neutral distractors presented at various stimulus-onset asynchronies. Experiment 1 showed Stroop interference and facilitation for initial keystroke latencies and errors, contrasting with response durations (a measure of response execution) being unaffected by Stroop manipulation. Experiment 2 showed that all three measures were responsive to time pressure; again, Stroop effects were confined to latencies and errors only. The observation that response duration is both flexible under time pressure and protected from response competition, may imply either that response execution is structurally segregated from earlier processing stages, or that encapsulation develops during the acquisition of typing skills.

  11. Impulse response measurement in the HgCdTe avalanche photodiode

    NASA Astrophysics Data System (ADS)

    Singh, Anand; Pal, Ravinder

    2018-04-01

    HgCdTe based mid-wave infrared focal plane arrays (MWIR FPAs) are being developed for high resolution imaging and range determination of distant camouflaged targets. Effect of bandgap grading on the response time in the n+/ν/p+ HgCdTe electron avalanche photodiode (e-APD) is evaluated using impulse response measurement. Gain normalized dark current density of 2 × 10-9 A/cm2 at low reverse bias for passive mode and 2 × 10-4 A/cm2 at -8 V for active mode is measured in the fabricated APD device, yielding high gain bandwidth product of 2.4 THZ at the maximum gain. Diffusion of carriers is minimized to achieve transit time limited impulse response by introducing composition grading in the HgCdTe epilayer. The noise equivalent photon performance less than one is achievable in the FPA that is suitable for active cum passive imaging applications.

  12. Investigation of PACE™ software and VeriFax's Impairoscope device for quantitatively measuring the effects of stress

    NASA Astrophysics Data System (ADS)

    Morgenthaler, George W.; Nuñez, German R.; Botello, Aaron M.; Soto, Jose; Shrairman, Ruth; Landau, Alexander

    1998-01-01

    Many reaction time experiments have been conducted over the years to observe human responses. However, most of the experiments that were performed did not have quantitatively accurate instruments for measuring change in reaction time under stress. There is a great need for quantitative instruments to measure neuromuscular reaction responses under stressful conditions such as distraction, disorientation, disease, alcohol, drugs, etc. The two instruments used in the experiments reported in this paper are such devices. Their accuracy, portability, ease of use, and biometric character are what makes them very special. PACE™ is a software model used to measure reaction time. VeriFax's Impairoscope measures the deterioration of neuromuscular responses. During the 1997 Summer Semester, various reaction time experiments were conducted on University of Colorado faculty, staff, and students using the PACE™ system. The tests included both two-eye and one-eye unstressed trials and trials with various stresses such as fatigue, distractions in which subjects were asked to perform simple arithmetic during the PACE™ tests, and stress due to rotating-chair dizziness. Various VeriFax Impairoscope tests, both stressed and unstressed, were conducted to determine the Impairoscope's ability to quantitatively measure this impairment. In the 1997 Fall Semester, a Phase II effort was undertaken to increase test sample sizes in order to provide statistical precision and stability. More sophisticated statistical methods remain to be applied to better interpret the data.

  13. Measuring temperature dependence of soil respiration: importance of incubation time, soil type, moisture content and model fits

    NASA Astrophysics Data System (ADS)

    Schipper, L. A.; Robinson, J.; O'Neill, T.; Ryburn, J.; Arcus, V. L.

    2015-12-01

    Developing robust models of the temperature response and sensitivity of soil respiration is critical for determining changes carbon cycling in response to climate change and at daily to annual time scales. Currently, approaches for measuring temperature dependence of soil respiration generally use long incubation times (days to weeks and months) at a limited number of incubation temperatures. Long incubation times likely allow thermal adaptation by the microbial population so that results are poorly representative of in situ soil responses. Additionally, too few incubation temperatures allows for the fit and justification of many different predictive equations, which can lead to inaccuracies when used for carbon budgeting purposes. We have developed a method to rapidly determine the response of soil respiration rate to wide range of temperatures. An aluminium block with 44 sample slots is heated at one end and cooled at the other to give a temperature gradient from 0 to 55°C at about one degree increments. Soil respiration is measured within 5 hours to minimise the possibility of thermal adaptation. We have used this method to demonstrate the similarity of temperature sensitivity of respiration for different soils from the same location across seasons. We are currently testing whether long-term (weeks to months) incubation alter temperature response and sensitivity that occurs in situ responses. This method is also well suited for determining the most appropriate models of temperature dependence and sensitivity of soil respiration (including macromolecular rate theory MMRT). With additional testing, this method is expected to be a more reliable method of measuring soil respiration rate for soil quality and modelling of soil carbon processes.

  14. Responsiveness of physical function outcomes following physiotherapy intervention for osteoarthritis of the knee: an outcome comparison study.

    PubMed

    French, Helen P; Fitzpatrick, Martina; FitzGerald, Oliver

    2011-12-01

    To compare the responsiveness of two self-report measures and three physical performance measures of function following physiotherapy for osteoarthritis of the knee. Single centre study in acute hospital setting. Patients referred for physiotherapy with osteoarthritis of the knee were recruited. The Western Ontario and McMaster Universities (WOMAC), Lequesne Algofunctional Index (LAI), timed-up-and-go test (TUGT), timed-stand test (TST) and six-minute walk test (6MWT) were administered at first and final physiotherapy visits. Wilcoxon Signed Rank tests were used to determine the effect of physiotherapy on each outcome. Responsiveness was calculated using effect size, standardised response mean and a median-based measure of responsiveness due to some outlying data. Thirty-nine patients with a mean age of 65.3 (standard deviation 6.9) years were investigated before and after a course of exercise-based physiotherapy. There was a significant improvement in all outcomes except the WOMAC scores. All measures demonstrated small effect sizes for all statistics (<0.50), except the 6MWT which was in the moderate range for one of the indices (standardised response mean 0.54). The LAI was more responsive than the WOMAC total score and the WOMAC physical function subscale for all responsiveness statistics, whilst the 6MWT was more responsive than the TST and the TUGT. The median-based effect size index produced the smallest effect sizes for all measures (0.1 to 0.43). These results can be used to guide decision making about which physical function outcome measures should be used to evaluate effectiveness of rehabilitation of people with osteoarthritis of the knee at group level in a clinical setting. Copyright © 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  15. Pump-Probe Noise Spectroscopy of Molecular Junctions.

    PubMed

    Ochoa, Maicol A; Selzer, Yoram; Peskin, Uri; Galperin, Michael

    2015-02-05

    The slow response of electronic components in junctions limits the direct applicability of pump-probe type spectroscopy in assessing the intramolecular dynamics. Recently the possibility of getting information on a sub-picosecond time scale from dc current measurements was proposed. We revisit the idea of picosecond resolution by pump-probe spectroscopy from dc measurements and show that any intramolecular dynamics not directly related to charge transfer in the current direction is missed by current measurements. We propose a pump-probe dc shot noise spectroscopy as a suitable alternative. Numerical examples of time-dependent and average responses of junctions are presented for generic models.

  16. Definition of simulated driving tests for the evaluation of drivers' reactions and responses.

    PubMed

    Bartolozzi, Riccardo; Frendo, Francesco

    2014-01-01

    This article aims at identifying the most significant measures in 2 perception-response (PR) tests performed at a driving simulator: a braking test and a lateral skid test, which were developed in this work. Forty-eight subjects (26 females and 22 males) with a mean age of 24.9 ± 3.0 years were enrolled for this study. They were asked to perform a drive on the driving simulator at the University of Pisa (Italy) following a specific test protocol, including 8-10 braking tests and 8-10 lateral skid tests. Driver input signals and vehicle model signals were recorded during the drives and analyzed to extract measures such as the reaction time, first response time, etc. Following a statistical procedure (based on analysis of variance [ANOVA] and post hoc tests), all test measures (3 for the braking test and 8 for the lateral skid test) were analyzed in terms of statistically significant differences among different drivers. The presented procedure allows evaluation of the capability of a given test to distinguish among different drivers. In the braking test, the reaction time showed a high dispersion among single drivers, leading to just 4.8 percent of statistically significant driver pairs (using the Games-Howell post hoc test), whereas the pedal transition time scored 31.9 percent. In the lateral skid test, 28.5 percent of the 2 × 2 comparisons showed significantly different reaction times, 19.5 percent had different response times, 35.2 percent had a different second peak of the steering wheel signal, and 33 percent showed different values of the integral of the steering wheel signal. For the braking test, which has been widely employed in similar forms in the literature, it was shown how the reaction time, with respect to the pedal transition time, can have a higher dispersion due to the influence of external factors. For the lateral skid test, the following measures were identified as the most significant for application studies: the reaction time for the reaction phase, the second peak of the steering wheel angle for the first instinctive response, and the integral of the steering wheel angle for the complete response. The methodology used to analyze the test measures was founded on statistically based and objective evaluation criteria and could be applied to other tests. Even if obtained with a fixed-base simulator, the obtained results represent useful information for applications of the presented PR tests in experimental campaigns with driving simulators.

  17. Pursuit Latency for Chromatic Targets

    NASA Technical Reports Server (NTRS)

    Mulligan, Jeffrey B.; Ellis, Stephen R. (Technical Monitor)

    1998-01-01

    The temporal dynamics of eye movement response to a change in direction of stimulus motion has been used to compare the processing speeds of different types of stimuli (Mulligan, ARVO '97). In this study, the pursuit response to colored targets was measured to test the hypothesis that the slow response of the chromatic system (as measured using traditional temporal sensitivity measures such as contrast sensitivity) results in increased eye movement latencies. Subjects viewed a small (0.4 deg) Gaussian spot which moved downward at a speed of 6.6 deg/sec. At a variable time during the trajectory, the dot's direction of motion changed by 30 degrees, either to the right or left. Subjects were instructed to pursue the spot. Eye movements were measured using a video ophthalmoscope with an angular resolution of approximately 1 arc min and a temporal sampling rate of 60 Hz. Stimuli were modulated in chrominance for a variety of hue directions, combined with a range of small luminance increments and decrements, to insure that some of the stimuli fell in the subjects' equiluminance planes. The smooth portions of the resulting eye movement traces were fit by convolving the stimulus velocity with an exponential having variable onset latency, time constant and amplitude. Smooth eye movements with few saccades were observed for all stimuli. Pursuit responses to stimuli having a significant luminance component are well-fit by exponentials having latencies and time constants on the order of 100 msec. Increases in pursuit response latency on the order of 100-200 msec are observed in response to certain stimuli, which occur in pairs of complementary hues, corresponding to the intersection of the stimulus section with the subjects' equiluminant plane. Smooth eye movements can be made in response to purely chromatic stimuli, but are slower than responses to stimuli with a luminance component.

  18. Operational characteristics of a translation screen grid beam deflection system for a 5-cm Kaufman thruster

    NASA Technical Reports Server (NTRS)

    Lathem, W. C.; Hudson, W. R.

    1972-01-01

    Measurements of beam deflection angle with respect to spring positioning power and accelerator impingement current as a function of deflection angle were made on a 5-cm diameter system. Response time measurements on the translational grid beam deflection system showed that the time for the maximum deflection angle analyzed (+16.4 deg to -16.4 deg) could be reduced by a factor of nine by increasing the heating power applied to the positioning spring from 4 to 16 watts. At 14 watts the response time for maximum deflection was about 1 minute.

  19. Highly stretchable miniature strain sensor for large dynamic strain measurement

    DOE PAGES

    Song, Bo; Yao, Shurong; Nie, Xu; ...

    2016-01-01

    In this paper, a new type of highly stretchable strain sensor was developed to measure large strains. The sensor was based on the piezo-resistive response of carbon nanotube (CNT)/polydimethylsiloxane (PDMS) composite thin films. The piezo-resistive response of CNT composite gives accurate strain measurement with high frequency response, while the ultra-soft PDMS matrix provides high flexibility and ductility for large strain measurement. Experimental results show that the CNT/PDMS sensor measures large strains (up to 8 %) with an excellent linearity and a fast frequency response. The new miniature strain sensor also exhibits much higher sensitivities than the conventional foil strain gages,more » as its gauge factor is 500 times of that of the conventional foil strain gages.« less

  20. Determination of eddy current response with magnetic measurements.

    PubMed

    Jiang, Y Z; Tan, Y; Gao, Z; Nakamura, K; Liu, W B; Wang, S Z; Zhong, H; Wang, B B

    2017-09-01

    Accurate mutual inductances between magnetic diagnostics and poloidal field coils are an essential requirement for determining the poloidal flux for plasma equilibrium reconstruction. The mutual inductance calibration of the flux loops and magnetic probes requires time-varying coil currents, which also simultaneously drive eddy currents in electrically conducting structures. The eddy current-induced field appearing in the magnetic measurements can substantially increase the calibration error in the model if the eddy currents are neglected. In this paper, an expression of the magnetic diagnostic response to the coil currents is used to calibrate the mutual inductances, estimate the conductor time constant, and predict the eddy currents response. It is found that the eddy current effects in magnetic signals can be well-explained by the eddy current response determination. A set of experiments using a specially shaped saddle coil diagnostic are conducted to measure the SUNIST-like eddy current response and to examine the accuracy of this method. In shots that include plasmas, this approach can more accurately determine the plasma-related response in the magnetic signals by eliminating the field due to the eddy currents produced by the external field.

  1. It Takes Time to Prime: Semantic Priming in the Ocular Lexical Decision Task

    PubMed Central

    Hoedemaker, Renske S.; Gordon, Peter C.

    2014-01-01

    Two eye-tracking experiments were conducted in which the manual response mode typically used in lexical decision tasks (LDT) was replaced with an eye-movement response through a sequence of three words. This ocular LDT combines the explicit control of task goals found in LDTs with the highly practiced ocular response used in reading text. In Experiment 1, forward saccades indicated an affirmative LD on each word in the triplet. In Experiment 2, LD responses were delayed until all three letter strings had been read. The goal of the study was to evaluate the contribution of task goals and response mode to semantic priming. Semantic priming is very robust in tasks that involve recognition of words in isolation, such as LDT, while limited during text reading as measured using eye movements. Gaze durations in both experiments showed robust semantic priming even though ocular response times were much shorter than manual LDs for the same words in the English Lexicon Project. Ex-Gaussian distribution fits revealed that the priming effect was concentrated in estimates of τ, meaning that priming was most pronounced in the slow tail of the distribution. This pattern shows differential use of the prime information, which may be more heavily recruited in cases where the LD is difficult as indicated by longer response times. Compared to the manual LD responses, ocular LDs provide a more sensitive measure of this task-related influence on word recognition as measured by the LDT. PMID:25181368

  2. Rain pulses - how different data streams provide insight in response-times and help to attribute biophysical properties to ecosystem processes.

    NASA Astrophysics Data System (ADS)

    El-Madany, T. S.; Migliavacca, M.; Perez-Priego, O.; Luo, Y.; Kolle, O.; Carrara, A.; Moreno, G.; Reichstein, M.

    2017-12-01

    Rain pulses play a major role for the carbon cycle in semiarid ecosystems, as they can release large amounts of stored carbon. Physical and biological processes, triggered by the availability of water start to develop on various time scales and are dependent on the amount of available water. Especially, in savanna type ecosystems with an herbaceous understory and sparsely distributed trees the response time of the two plant functional types to rain pulses might be different. We present results from an ongoing large-scale nutrient manipulation experiment (MANIP) in a Mediterranean savanna type ecosystem and its response to rain pulses. Within MANIP the footprint areas from two out of three ecosystem eddy co-variance (EC) sites were fertilized with nitrogen (NT) and nitrogen plus phosphorous (NPT), the third served as the control (CT). The analysis combines EC data to determine the net ecosystem exchange, PhenoCam data to define the senescence and re-greening period, SAP-flow measurements to evaluate the response of trees to rain pulses, high frequency (1 Hz) CO2-concentration measurements to estimate the response time to of the ecosystem to rain pulses, and meteorological measurements to quantify the intensity of the rain pulses. Additionally, at NT canopy reflectance and SIF are measured continuously for trees and grasses. The combination of SIF and SAP-flow measurements allows to separate the contribution of trees to ecosystem fluxes and can be utilized to partition NEE into ecosystem respiration and gross primary productivity during the senescence period. The analyses focus on three topics; (i) utilizing high frequency dynamics of CO2 concentration to disentangle physical and biological responses to water availability; (ii) fertilization effect of respiration pulses on ecosystem fluxes; (iii) response of tree transpiration to rain pulses. CO2 concentrations show an instantaneous reaction to rain fall. Within minutes concentrations increase strongly and follow distinct patterns. The fertilization effect is not clear in terms of respiration magnitude triggered by the rain pulse but the fertilized areas show slightly more carbon uptake during daytime after a precipitation pulse. Sap-flow measurements indicate a response of the trees to the rain pulses which effect nocturnal and daytime sap velocities.

  3. Recovery from exercise at varying work loads - Time course of responses of heart rate and systolic intervals

    NASA Technical Reports Server (NTRS)

    Nandi, P. S.; Spodick, D. H.

    1977-01-01

    The time course of the recovery period was characterized by noninvasive measurements after 4 minute bicycle exercise at 3 separate work loads in volunteers with normal peak responses. Most responses started immediately to return toward resting control values. Left ventricular ejection time and stroke volume change are discussed. Changes in pre-ejection period were determined by changes in isovolume contraction time, and factors affecting the degree and rate of return are considered. The rates of change in the ejection time index and in the ratio pre-ejection period/left ventricular ejection time were virtually independent of load throughout most of recovery.

  4. Exposure and peritraumatic response as predictors of posttraumatic stress in children following the 1995 Oklahoma City bombing.

    PubMed

    Pfefferbaum, Betty; Doughty, Debby E; Reddy, Chandrashekar; Patel, Nilam; Gurwitch, Robin H; Nixon, Sara Jo; Tivis, Rick D

    2002-09-01

    Studies have demonstrated a positive relationship between exposure and posttraumatic stress, but one's subjective appraisal of danger and threat at the time of exposure may be a better predictor of posttraumatic stress than more objective measures of exposure. We examined the role of peritraumatic response in posttraumatic stress reactions in over 2,000 middle school children 7 weeks after the 1995 Oklahoma City, Oklahoma, bombing. While many children reported hearing and feeling the blast and knowing direct victims, most were in school at the time of the explosion and therefore were not in direct physical proximity to the incident. Physical, interpersonal, and television exposure accounted for 12% of the total variance in our measure of posttraumatic stress when peritraumatic response was ignored. Peritraumatic response and television exposure accounted for 25% of the total variance, and physical and interpersonal exposure were not significant in this context. These findings suggest the importance of peritraumatic response in children's reactions to terrorism. These early responses can be used to help determine which children may experience difficulty over time.

  5. Timing in Trace Conditioning of the Nictitating Membrane Response of the Rabbit ("Oryctolagus Cuniculus"): Scalar, Nonscalar, and Adaptive Features

    ERIC Educational Resources Information Center

    Kehoe, E. James; Ludvig, Elliot A.; Sutton, Richard S.

    2010-01-01

    Using interstimulus intervals (ISIs) of 125, 250, and 500 msec in trace conditioning of the rabbit nictitating membrane response, the offset times and durations of conditioned responses (CRs) were collected along with onset and peak latencies. All measures were proportional to the ISI, but only onset and peak latencies conformed to the criterion…

  6. Does spending time outdoors reduce stress? A review of real-time stress response to outdoor environments

    Treesearch

    Michelle C. Kondo; Sara F. Jacoby; Eugenia C. South

    2018-01-01

    Everyday environmental conditions impact human health. One mechanism underlying this relationship is the experience of stress. Through systematic review of published literature, we explore how stress has been measured in real-time non-laboratory studies of stress responses to deliberate exposure to outdoor environments. The types of exposures evaluated in this review...

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Bo; Yao, Shurong; Nie, Xu

    In this paper, a new type of highly stretchable strain sensor was developed to measure large strains. The sensor was based on the piezo-resistive response of carbon nanotube (CNT)/polydimethylsiloxane (PDMS) composite thin films. The piezo-resistive response of CNT composite gives accurate strain measurement with high frequency response, while the ultra-soft PDMS matrix provides high flexibility and ductility for large strain measurement. Experimental results show that the CNT/PDMS sensor measures large strains (up to 8 %) with an excellent linearity and a fast frequency response. The new miniature strain sensor also exhibits much higher sensitivities than the conventional foil strain gages,more » as its gauge factor is 500 times of that of the conventional foil strain gages.« less

  8. Response-time enhancement of a clinical gas analyzer facilitates measurement of breath-by-breath gas exchange.

    PubMed

    Farmery, A D; Hahn, C E

    2000-08-01

    Tidal ventilation gas-exchange models in respiratory physiology and medicine not only require solution of mass balance equations breath-by-breath but also may require within-breath measurements, which are instantaneous functions of time. This demands a degree of temporal resolution and fidelity of integration of gas flow and concentration signals that cannot be provided by most clinical gas analyzers because of their slow response times. We have characterized the step responses of the Datex Ultima (Datex Instrumentation, Helsinki, Finland) gas analyzer to oxygen, carbon dioxide, and nitrous oxide in terms of a Gompertz four-parameter sigmoidal function. By inversion of this function, we were able to reduce the rise times for all these gases almost fivefold, and, by its application to real on-line respiratory gas signals, it is possible to achieve a performance comparable to the fastest mass spectrometers. With the use of this technique, measurements required for non-steady-state and tidal gas-exchange models can be made easily and reliably in the clinical setting.

  9. Responsive upper limb and cognitive fatigue measures during light precision work: an 8-hour simulated micro-pipetting study.

    PubMed

    Yung, Marcus; Wells, Richard P

    2017-07-01

    Many contemporary occupations are characterised by long periods of low loads. These lower force levels, which are relevant to the development of work-related musculoskeletal disorders, are usually not the focus of fatigue studies. In studies that did measure fatigue in light manual or precision work, within and between measurement responses were inconsistent. The aim of this study was to identify fatigue measures that were responsive at lower force levels (<10% MVC) over the course of an 8-h period. A complementary set of fatigue measures, reflecting both neuromuscular and cognitive mechanisms, was measured during a light precision micro-pipetting task performed by 11 participants. Nine measures were found to be significantly responsive over the 8-h period, including: ratings of perceived fatigue, postural tremor, blink frequency and critical flicker fusion frequency threshold. Common field measures, specifically electromyography RMS amplitude and maximum voluntary contractions, did not lead to extraordinary time effects. Practitioner summary: The findings provide insight towards the responsiveness of a complementary set of field usable fatigue measures at low work intensities Although commonly used measures did not reveal significant increases in fatigue, nine alternative measures were significantly responsive over the 8-h period.

  10. Neutron response function characterization of 4He scintillation detectors

    DOE PAGES

    Kelley, Ryan P.; Rolison, Lucas M.; Lewis, Jason M.; ...

    2015-04-15

    Time-of-flight measurements were conducted to characterize the neutron energy response of pressurized 4He fast neutron scintillation detectors for the first time, using the Van de Graaff generator at Ohio University. The time-of-flight spectra and pulse height distributions were measured. This data was used to determine the light output response function, which was found to be linear at energies below 3.5 MeV. The intrinsic efficiency of the detector as a function of incident energy was also calculated: the average efficiency up to 10 MeV was 3.1%, with a maximum efficiency of 6.6% at 1.05 MeV. Furthermore, these results will enable developmentmore » of neutron spectrum unfolding algorithms for neutron spectroscopy applications with these detectors.« less

  11. Method and apparatus for measuring response time

    DOEpatents

    Johanson, Edward W.; August, Charles

    1985-01-01

    A method of measuring the response time of an electrical instrument which generates an output signal in response to the application of a specified input, wherein the output signal varies as a function of time and when subjected to a step input approaches a steady-state value, comprises the steps of: (a) applying a step input of predetermined value to the electrical instrument to generate an output signal; (b) simultaneously starting a timer; (c) comparing the output signal to a reference signal to generate a stop signal when the output signal is substantially equal to the reference signal, the reference signal being a specified percentage of the steady-state value of the output signal corresponding to the predetermined value of the step input; and (d) applying the stop signal when generated to stop the timer.

  12. Method and apparatus for measuring response time

    DOEpatents

    Johanson, E.W.; August, C.

    1983-08-11

    A method of measuring the response time of an electrical instrument which generates an output signal in response to the application of a specified input, wherein the output signal varies as a function of time and when subjected to a step input approaches a steady-state value, comprises the steps of: (a) applying a step input of predetermined value to the electrical instrument to generate an output signal; (b) simultaneously starting a timer; (c) comparing the output signal to a reference signal to generate a stop signal when the output signal is substantially equal to the reference signal, the reference signal being a specified percentage of the steady-state value of the output signal corresponding to the predetermined value of the step input; and (d) applying the stop signal when generated to stop the timer.

  13. Measurement of material nonlinearity using surface acoustic wave parametric interaction and laser ultrasonics.

    PubMed

    Stratoudaki, Theodosia; Ellwood, Robert; Sharples, Steve; Clark, Matthew; Somekh, Michael G; Collison, Ian J

    2011-04-01

    A dual frequency mixing technique has been developed for measuring velocity changes caused by material nonlinearity. The technique is based on the parametric interaction between two surface acoustic waves (SAWs): The low frequency pump SAW generated by a transducer and the high frequency probe SAW generated and detected using laser ultrasonics. The pump SAW stresses the material under the probe SAW. The stress (typically <5 MPa) is controlled by varying the timing between the pump and probe waves. The nonlinear interaction is measured as a phase modulation of the probe SAW and equated to a velocity change. The velocity-stress relationship is used as a measure of material nonlinearity. Experiments were conducted to observe the pump-probe interaction by changing the pump frequency and compare the nonlinear response of aluminum and fused silica. Experiments showed these two materials had opposite nonlinear responses, consistent with previously published data. The technique could be applied to life-time predictions of engineered components by measuring changes in nonlinear response caused by fatigue.

  14. Electrodermal responses during appetitive conditioning are sensitive to contingency instruction ambiguity.

    PubMed

    van den Akker, Karolien; Nederkoorn, Chantal; Jansen, Anita

    2017-08-01

    Studies on human appetitive conditioning using food rewards can benefit from including psychophysiological outcome measures. The present study tested whether the skin conductance response can function as a measure of differential responding in an appetitive conditioning paradigm including an acquisition and extinction phase, and examined which time window during a trial is most sensitive to conditioning effects. As a secondary aim, the effects of ambiguous vs. non-ambiguous contingency instructions on conditioned responses (skin conductance responses, US expectancies, chocolate desires, and CS evaluations) were assessed. Results indicated differential skin conductance responses in an anticipatory time window and during unexpected omission of the US in early extinction. Interestingly however, anticipatory responses were only found for participants who received ambiguous contingency instructions - possibly indicating a call for additional processing resources in response to the ambiguous CS+. Further, ambiguous instructions slowed the extinction of US expectancies but did not influence chocolate desires and CS evaluations. It is concluded that skin conductance can function as a sensitive measure of differential responding in appetitive conditioning, though its sensitivity might depend on the specific task context. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Quantitative assessment of responses of the eyeball based on data from the Corvis tonometer.

    PubMed

    Koprowski, Robert; Wilczyński, Sławomir; Nowinska, Anna; Lyssek-Boron, Anita; Teper, Sławomir; Wylegala, Edward; Wróbel, Zygmunt

    2015-03-01

    The "air-puff" tonometers, include the Corvis, are a type of device for measuring intraocular pressure and biomechanics parameters. The paper attempts to analyse this response and its relationship with other parameters measured in the Corvis tonometer. A number of 13,400 2D images were acquired from the Corvis device and analysed (32 healthy and 16 ill people). A new method has been proposed for the analysis of responses of the eyeball based on morphological transformations and contextual operations. The proposed algorithm enables to determine responses of the eyeball to an air puff coming from the Corvis tonometer. Additionally, responses of the eyeball have been linked to some selected features of corneal deformation. The results include, among others: (1) distinguishability between the left and right eye with an error of 7%; (2) the correlation between the area under the curve in corneal deformation and the response of the eyeball -0.26; (3) the correlation between the highest concavity time and the maximum deformation amplitude of 0.4. All these features are obtained fully automatically and repetitively at a time of 3.8s per patient (Core i7 10GB RAM). It is possible to measure additional parameters of the eye deformation which are not available in the original software of the Corvis tonometer. The use of the proposed methods of image analysis and processing provides results directly from the eye response measurement when measuring intraocular pressure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. [Construction of the Time Management Scale and examination of the influence of time management on psychological stress response].

    PubMed

    Imura, Tomoya; Takamura, Masahiro; Okazaki, Yoshihiro; Tokunaga, Satoko

    2016-10-01

    We developed a scale to measure time management and assessed its reliability and validity. We then used this scale to examine the impact of time management on psychological stress response. In Study 1-1, we developed the scale and assessed its internal consistency and criterion-related validity. Findings from a factor analysis revealed three elements of time management, “time estimation,” “time utilization,” and “taking each moment as it comes.” In Study 1-2, we assessed the scale’s test-retest reliability. In Study 1-3, we assessed the validity of the constructed scale. The results indicate that the time management scale has good reliability and validity. In Study 2, we performed a covariance structural analysis to verify our model that hypothesized that time management influences perceived control of time and psychological stress response, and perceived control of time influences psychological stress response. The results showed that time estimation increases the perceived control of time, which in turn decreases stress response. However, we also found that taking each moment as it comes reduces perceived control of time, which in turn increases stress response.

  17. Toward Online Measurement of Decision State

    NASA Technical Reports Server (NTRS)

    Lachter, Joel; Johnston, James C.; Corrado, Greg S.; McClelland, James L.

    2009-01-01

    In traditional perceptual decision-making experiments, two pieces of data are collected on each trial: response time and accuracy. But how confident were participants and how did their decision state evolve over time? We asked participants to provide a continuous readout of their decision state by moving a cursor along a sliding scale between a 100% certain left response and a 100% certain right response. Subjects did not terminate the trials; rather, trials were timed out at random and subjects were scored based on the cursor position at that time. Higher rewards for correct responses and higher penalties for errors were associated with extreme responses so that the response with the highest expected value was that which accurately reflected the participant's odds of being correct. This procedure encourages participants to expose the time-course of their evolving decision state. Evidence on how well they can do this will be presented.

  18. Toward Online Measurement of Decision State

    NASA Technical Reports Server (NTRS)

    Lachter, Joel; Johnston, James C.; Corrado, Greg S.; McClelland, James L.

    2009-01-01

    In traditional perceptual decision-making experiments, two pieces of data recollected on each trial: response time and accuracy. But how confident were participants and how did their decision state evolve over time? We asked participants to provide a continuous readout of their decision state by moving a cursor along a sliding scale between a 100% certain left response and a 100% certain right response. Subjects did not terminate the trials; rather, trials were timed out at random and subjects were scored based on the cursor position at the time. Higher rewards for correct responses and higher penalties for errors were associated with extreme responses so that the response with the highest ex[pected value was that which accurately reflected the participant's odds of being correct. This procedure encourages participants to expose the time-course of their evolving decision state. Evidence on how well they can do this will be presented.

  19. Cone responses in Usher syndrome types 1 and 2 by microvolt electroretinography.

    PubMed

    Zein, Wadih M; Falsini, Benedetto; Tsilou, Ekaterina T; Turriff, Amy E; Schultz, Julie M; Friedman, Thomas B; Brewer, Carmen C; Zalewski, Christopher K; King, Kelly A; Muskett, Julie A; Rehman, Atteeq U; Morell, Robert J; Griffith, Andrew J; Sieving, Paul A

    2014-11-25

    Progressive decline of psychophysical cone-mediated measures has been reported in type 1 (USH1) and type 2 (USH2) Usher syndrome. Conventional cone electroretinogram (ERG) responses in USH demonstrate poor signal-to-noise ratio. We evaluated cone signals in USH1 and USH2 by recording microvolt level cycle-by-cycle (CxC) ERG. Responses of molecularly genotyped USH1 (n = 18) and USH2 (n = 24) subjects (age range, 15-69 years) were compared with those of controls (n = 12). A subset of USH1 (n = 9) and USH2 (n = 9) subjects was examined two to four times over 2 to 8 years. Photopic CxC ERG and conventional 30-Hz flicker ERG were recorded on the same visits. Usher syndrome subjects showed considerable cone flicker ERG amplitude losses and timing phase delays (P < 0.01) compared with controls. USH1 and USH2 had similar rates of progressive logarithmic ERG amplitude decline with disease duration (-0.012 log μV/y). Of interest, ERG phase delays did not progress over time. Two USH1C subjects retained normal response timing despite reduced amplitudes. The CxC ERG method provided reliable responses in all subjects, whereas conventional ERG was undetectable in 7 of 42 subjects. Cycle-by-cycle ERG showed progressive loss of amplitude in both USH1 and USH2 subjects, comparable to that reported with psychophysical measures. Usher subjects showed abnormal ERG response latency, but this changed less than amplitude with time. In USH syndrome, CxC ERG is more sensitive than conventional ERG and warrants consideration as an outcome measure in USH treatment trials. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  20. Kinetic operational models of agonism for G-protein-coupled receptors.

    PubMed

    Hoare, Samuel R J; Pierre, Nicolas; Moya, Arturo Gonzalez; Larson, Brad

    2018-06-07

    The application of kinetics to research and therapeutic development of G-protein-coupled receptors has become increasingly valuable. Pharmacological models provide the foundation of pharmacology, providing concepts and measurable parameters such as efficacy and potency that have underlain decades of successful drug discovery. Currently there are few pharmacological models that incorporate kinetic activity in such a way as to yield experimentally-accessible drug parameters. In this study, a kinetic model of pharmacological response was developed that provides a kinetic descriptor of efficacy (the transduction rate constant, k τ ) and allows measurement of receptor-ligand binding kinetics from functional data. The model assumes: (1) receptor interacts with a precursor of the response ("Transduction potential") and converts it to the response. (2) The response can decay. Familiar response vs time plots emerge, depending on whether transduction potential is depleted and/or response decays. These are the straight line, the "association" exponential curve, and the rise-and-fall curve. Convenient, familiar methods are described for measuring the model parameters and files are provided for the curve-fitting program Prism (GraphPad Software) that can be used as a guide. The efficacy parameter k τ is straightforward to measure and accounts for receptor reserve; all that is required is measurement of response over time at a maximally-stimulating concentration of agonist. The modular nature of the model framework allows it to be extended. Here this is done to incorporate antagonist-receptor binding kinetics and slow agonist-receptor equilibration. In principle, the modular framework can incorporate other cellular processes, such as receptor desensitization. The kinetic response model described here can be applied to measure kinetic pharmacological parameters than can be used to advance the understanding of GPCR pharmacology and optimize new and improved therapeutics. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Development of a Transient Thrust Stand with Sub-Millisecond Resolution

    NASA Astrophysics Data System (ADS)

    Spells, Corbin Fraser

    The transient thrust stand has been developed to offer 0.1 ms time resolved thrust measurements for the characterization of mono-propellant thrusters for spacecraft applications. Results demonstrated that the system was capable of obtaining dynamic thrust profiles within 5 % and 0.1 ms. Measuring and improving the thrust performance of mono-propellant thrusters will require 1 ms time resolved forces to observe shot-to-shot variations, oscillations, and minimum impulse bits. To date, no thrust stand is capable of measuring up to 22 N forces with a time response of up to 10 kHz. Calibration forces up to 22 N with a frequency response greater than 0.1 ms were obtained using voice coil actuators. Steady state and low frequency measurements were obtained using displacement and velocity sensors and were combined with high frequency vibration modes measured using several accelerometers along the thrust stand arm. The system uses a predictor-based subspace algorithm to obtain a high order state space model of the thrust stand capable of defining the high frequency vibration modes. The high frequency vibration modes are necessary to provide the time response of 0.1 ms. Thruster forces are estimated using an augmented Kalman filter to combine sensor traces from four accelerometers, a velocity sensor, and displacement transducer. Combining low frequency displacement data with high frequency acceleration measurements provides accurate force data across a broad time domain. The transient thrust stand uses a torsional pendulum configuration to minimize influence from external vibration and achieve high force resolution independent of thruster weight.

  2. Count me in: response to sexual orientation measures among older adults.

    PubMed

    Fredriksen-Goldsen, Karen I; Kim, Hyun-Jun

    2015-07-01

    Health disparities exist among sexual minority older adults. Yet, health and aging surveys rarely include sexual orientation measures and when they do, they often exclude older adults from being asked about sexual orientation. This is the first population-based study to assess item nonresponse to sexual orientation measures by age and change over time. We compare response rates and examine time trends in response patterns using adjusted logistic regressions. Among adults aged 65 and older, the nonresponse rate on sexual orientation is lower than income. While older adults show higher nonresponse rates on sexual orientation than younger adults, the nonresponse rates have significantly decreased over time. By 2010, only 1.23% of older adults responded don't know/not sure, with 1.55% refusing to answer sexual orientation questions. Decisions to not ask sexual orientation among older adults must be reconsidered, given documented health disparities and rapidly changing social trends in the understanding of diverse sexualities. © The Author(s) 2014.

  3. Estimation of tropical forest canopy temperatures, thermal response numbers, and evapotranspiration using an aircraft-based thermal sensor

    NASA Technical Reports Server (NTRS)

    Luvall, Jeffrey C.; Lieberman, Diana; Lieberman, Milton; Hartshorn, Gary S.; Peralta, Rodolfo

    1990-01-01

    Thermal infrared Multispectral Scanner (TIMS) data were collected at a resolution of 5 to 10 m from a tropical rain forest over an elevation gradient from 35 to 2700 m in the Braulio Carrillo National Park in Costa Rica. Flight lines were repeated with a 15 to 30 minute time difference for measurement of forest canopy thermal response over time. Concurrent radiosonde measurements of atmospheric profiles of air temperature and moisture provided inputs to LOWTRAN6 for atmospheric radiance corrections of the TIMS data. Techniques for using calibrated aircraft-based thermal scanner data to examine tropical forest canopy thermal properties are described. Forest canopy temperature changes over time assessed between repeated, duplicated flight lines were combined with estimates of surface radiative energy measurements from towers above the forest canopy to determine temperature spatial variability, calculate Thermal Response Numbers (TRN), and estimate evapotranspiration along the elevation gradient from selected one hectare forest inventory plots.

  4. An Accuracy--Response Time Capacity Assessment Function that Measures Performance against Standard Parallel Predictions

    ERIC Educational Resources Information Center

    Townsend, James T.; Altieri, Nicholas

    2012-01-01

    Measures of human efficiency under increases in mental workload or attentional limitations are vital in studying human perception, cognition, and action. Assays of efficiency as workload changes have typically been confined to either reaction times (RTs) or accuracy alone. Within the realm of RTs, a nonparametric measure called the "workload…

  5. Consistency between subjectively and objectively measured hazard perception skills among young male drivers.

    PubMed

    Ābele, Līva; Haustein, Sonja; Møller, Mette; Martinussen, Laila M

    2018-03-01

    Young male drivers have lower hazard perception skills (HPS) than older and more experienced drivers and a tendency to overestimate their skills in hazardous situations. Both factors contribute to an over-representation in traffic accidents. Based on a sample of 63 drivers aged 18-24, this study compares the consistency of HPS measured by objective and subjective measures and the link between these measures is the key contribution of the study. Both visible and hidden hazards are included. Objective measures of HPS include responsiveness and eye movements while driving in a driving simulator. Subjective measures of HPS include self-reports derived based on the Hazard Perception Questionnaire (HPQ), Driving Skill Questionnaire (DSQ), and Brief Sensation Seeking Scale (BSSS). Results show that drivers who respond to the hazards on time, as compared to drivers who do not respond, have higher scores on subjective measures of HPS and higher driving skills in the visible but not in the hidden condition. Eye movement analysis confirms the difference and shows that response in time to hazards indicate higher HPS and young drivers are poor at detecting hidden hazards. Drivers with a response in time locate the hazard faster, have more fixations, but dwell less on the hazard. At the same time, those who do not respond have a later first fixation and fewer but longer fixations on the hazard. High sensation seeking drivers respond to visible hazards on time, suggesting that sensation seeking does not affect HPS negatively when the hazard is visible. To enhance the HPS among young drivers, the results of this study suggest that specific hazard perception training is relevant, especially for hazards that require more advanced HPS. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Dual Mode NOx Sensor: Measuring Both the Accumulated Amount and Instantaneous Level at Low Concentrations

    PubMed Central

    Groß, Andrea; Beulertz, Gregor; Marr, Isabella; Kubinski, David J.; Visser, Jaco H.; Moos, Ralf

    2012-01-01

    The accumulating-type (or integrating-type) NOx sensor principle offers two operation modes to measure low levels of NOx: The direct signal gives the total amount dosed over a time interval and its derivative the instantaneous concentration. With a linear sensor response, no baseline drift, and both response times and recovery times in the range of the gas exchange time of the test bench (5 to 7 s), the integrating sensor is well suited to reliably detect low levels of NOx. Experimental results are presented demonstrating the sensor’s integrating properties for the total amount detection and its sensitivity to both NO and to NO2. We also show the correlation between the derivative of the sensor signal and the known gas concentration. The long-term detection of NOx in the sub-ppm range (e.g., for air quality measurements) is discussed. Additionally, a self-adaption of the measurement range taking advantage of the temperature dependency of the sensitivity is addressed. PMID:22736980

  7. Evaluating Curriculum-Based Measurement from a Behavioral Assessment Perspective

    ERIC Educational Resources Information Center

    Ardoin, Scott P.; Roof, Claire M.; Klubnick, Cynthia; Carfolite, Jessica

    2008-01-01

    Curriculum-based measurement Reading (CBM-R) is an assessment procedure used to evaluate students' relative performance compared to peers and to evaluate their growth in reading. Within the response to intervention (RtI) model, CBM-R data are plotted in time series fashion as a means modeling individual students' response to varying levels of…

  8. Methodological Issues in Measures of Imitative Reaction Times

    ERIC Educational Resources Information Center

    Aicken, Michael D.; Wilson, Andrew D.; Williams, Justin H. G.; Mon-Williams, Mark

    2007-01-01

    Ideomotor (IM) theory suggests that observing someone else perform an action activates an internal motor representation of that behaviour within the observer. Evidence supporting the case for an ideomotor theory of imitation has come from studies that show imitative responses to be faster than the same behavioural measures performed in response to…

  9. Breast tumor oxygenation in response to carbogen intervention assessed simultaneously by three oxygen-sensitive parameters

    NASA Astrophysics Data System (ADS)

    Gu, Yueqing; Bourke, Vincent; Kim, Jae Gwan; Xia, Mengna; Constantinescu, Anca; Mason, Ralph P.; Liu, Hanli

    2003-07-01

    Three oxygen-sensitive parameters (arterial hemoglobin oxygen saturation SaO2, tumor vascular oxygenated hemoglobin concentration [HbO2], and tumor oxygen tension pO2) were measured simultaneously by three different optical techniques (pulse oximeter, near infrared spectroscopy, and FOXY) to evaluate dynamic responses of breast tumors to carbogen (5% CO2 and 95% O2) intervention. All three parameters displayed similar trends in dynamic response to carbogen challenge, but with different response times. These response times were quantified by the time constants of the exponential fitting curves, revealing the immediate and the fastest response from the arterial SaO2, followed by changes in global tumor vascular [HbO2], and delayed responses for pO2. The consistency of the three oxygen-sensitive parameters demonstrated the ability of NIRS to monitor therapeutic interventions for rat breast tumors in-vivo in real time.

  10. Forced guidance and distribution of practice in sequential information processing.

    NASA Technical Reports Server (NTRS)

    Decker, L. R.; Rogers, C. A., Jr.

    1973-01-01

    Distribution of practice and forced guidance were used in a sequential information-processing task in an attempt to increase the capacity of human information-processing mechanisms. A reaction time index of the psychological refractory period was used as the response measure. Massing of practice lengthened response times while forced guidance shortened them. Interpretation was in terms of load reduction upon the response-selection stage of the information-processing system.-

  11. Study on the effect of measuring methods on incident photon-to-electron conversion efficiency of dye-sensitized solar cells by home-made setup.

    PubMed

    Guo, Xiao-Zhi; Luo, Yan-Hong; Zhang, Yi-Duo; Huang, Xiao-Chun; Li, Dong-Mei; Meng, Qing-Bo

    2010-10-01

    An experimental setup is built for the measurement of monochromatic incident photon-to-electron conversion efficiency (IPCE) of solar cells. With this setup, three kinds of IPCE measuring methods as well as the convenient switching between them are achieved. The setup can also measure the response time and waveform of the short-circuit current of solar cell. Using this setup, IPCE results of dye-sensitized solar cells (DSCs) are determined and compared under different illumination conditions with each method. It is found that the IPCE values measured by AC method involving the lock-in technique are sincerely influenced by modulation frequency and bias illumination. Measurements of the response time and waveform of short-circuit current have revealed that this effect can be explained by the slow response of DSCs. To get accurate IPCE values by this method, the measurement should be carried out with a low modulation frequency and under bias illumination. The IPCE values measured by DC method under the bias light illumination will be disturbed since the short-circuit current increased with time continuously due to the temperature rise of DSC. Therefore, temperature control of DSC is considered necessary for IPCE measurement especially in DC method with bias light illumination. Additionally, high bias light intensity (>2 sun) is found to decrease the IPCE values due to the ion transport limitation of the electrolyte.

  12. Temperature Insensitivity and Behavioural Reduction of the Physiological Stress Response to Longline Capture by the Gummy Shark, Mustelus antarcticus.

    PubMed

    Guida, Leonardo; Walker, Terence I; Reina, Richard D

    2016-01-01

    Many factors influence the physiological stress response to fisheries capture in elasmobranchs. However, the influence of sea surface temperatures (SST) and behaviour are unknown and crucial considering global fishing pressures. We investigated the effect of SST and behaviour on the physiological stress response to capture of the gummy shark, Mustelus antarcticus, and compared our results to a laboratory study using similar conditions to test whether stress responses of in situ capture are consistent with those from laboratory simulations. Capture time for 23 M. antarcticus ranged 32-241 min as measured by hook timers or time depth recorders (TDR) in SSTs ranging 12-20°C. TDR data from 13 M. antarcticus were analysed to quantify capture behaviour as the percentage of time spent moving during capture. Several physiological variables measured from blood samples obtained immediately upon the animals' landing indicated that although warmer SSTs increased metabolic rate, the stress response to capture was not exacerbated by capture duration. During capture movement occurred for an average of 10% of the time and since M. antarcticus can respire whilst stationary, restricted movement probably mitigated potential influences of increased SSTs and capture duration on the stress response. Previous laboratory findings were also shown to be indicative of in situ conditions and we thus advise that studies control for water temperature given the influence it has on variables (e.g. lactate) used to measure capture stress in elasmobranchs. We highlight the importance of seasonal water temperatures and capture behaviour when assessing the resilience to fisheries capture and the implementation of appropriate fisheries management strategies.

  13. Method for suppressing noise in measurements

    NASA Technical Reports Server (NTRS)

    Carson, Paul L. (Inventor); Madsen, Louis A. (Inventor); Leskowitz, Garett M. (Inventor); Weitekamp, Daniel P. (Inventor)

    2000-01-01

    Methods for suppressing noise in measurements by correlating functions based on at least two different measurements of a system at two different times. In one embodiment, a measurement operation is performed on at least a portion of a system that has a memory. A property of the system is measured during a first measurement period to produce a first response indicative of a first state of the system. Then the property of the system is measured during a second measurement period to produce a second response indicative of a second state of the system. The second measurement is performed after an evolution duration subsequent to the first measurement period when the system still retains a degree of memory of an aspect of the first state. Next, a first function of the first response is combined with a second function of the second response to form a second-order correlation function. Information of the system is then extracted from the second-order correlation function.

  14. Electrochemical sensors applied to pollution monitoring: Measurement error and gas ratio bias - A volcano plume case study

    NASA Astrophysics Data System (ADS)

    Roberts, T. J.; Saffell, J. R.; Oppenheimer, C.; Lurton, T.

    2014-06-01

    There is an increasing scientific interest in the use of miniature electrochemical sensors to detect and quantify atmospheric trace gases. This has led to the development of ‘Multi-Gas' systems applied to measurements of both volcanic gas emissions, and urban air pollution. However, such measurements are subject to uncertainties introduced by sensor response time, a critical issue that has received limited attention to date. Here, a detailed analysis of output from an electrochemical SO2 sensor and two H2S sensors (contrasting in their time responses and cross-sensitivities) demonstrates how instrument errors arise under the conditions of rapidly fluctuating (by dilution) gas abundances, leading to scatter and importantly bias in the reported gas ratios. In a case study at Miyakejima volcano (Japan), electrochemical sensors were deployed at both the crater-rim and downwind locations, thereby exposed to rapidly fluctuating and smoothly varying plume gas concentrations, respectively. Discrepancies in the H2S/SO2 gas mixing ratios derived from these measurements are attributed to the sensors' differing time responses to SO2 and H2S under fluctuating plume conditions, with errors magnified by the need to correct for SO2 interference in the H2S readings. Development of a sensor response model that reproduces sensor t90 behaviour (the time required to reach 90% of the final signal following a step change in gas abundance) during calibration enabled this measurement error to be simulated numerically. The sensor response times were characterised as SO2 sensor (t90 ~ 13 s), H2S sensor without interference (t90 ~ 11 s), and H2S sensor with interference (t90 ~ 20 s to H2S and ~ 32 s to SO2). We show that a method involving data integration between periods of episodic plume exposure identifiable in the sensor output yields a less biased H2S/SO2 ratio estimate than that derived from standard analysis approaches. For the Miyakejima crater-rim dataset this method yields highly correlated H2S and SO2 abundances (R2 > 0.99) and the improved crater-rim data analysis combined with downwind measurements yields H2S/SO2 = 0.11 ± 0.01. Our analysis has significant implications for the reliance that can be placed on ‘Multi-Gas'-derived gas ratios, whether for volcanological or other purposes, in the absence of consideration of the complexities of sensor response times.

  15. Delayed system response times affect immediate physiology and the dynamics of subsequent button press behavior.

    PubMed

    Kohrs, Christin; Hrabal, David; Angenstein, Nicole; Brechmann, André

    2014-11-01

    System response time research is an important issue in human-computer interactions. Experience with technical devices and general rules of human-human interactions determine the user's expectation, and any delay in system response time may lead to immediate physiological, emotional, and behavioral consequences. We investigated such effects on a trial-by-trial basis during a human-computer interaction by measuring changes in skin conductance (SC), heart rate (HR), and the dynamics of button press responses. We found an increase in SC and a deceleration of HR for all three delayed system response times (0.5, 1, 2 s). Moreover, the data on button press dynamics was highly informative since subjects repeated a button press with more force in response to delayed system response times. Furthermore, the button press dynamics could distinguish between correct and incorrect decisions and may thus even be used to infer the uncertainty of a user's decision. Copyright © 2014 Society for Psychophysiological Research.

  16. The potential benefits of repeated measure experiments for fish disease-challenge host-pathogen investigations.

    PubMed

    Hall, L Malcolm; Collins, Catherine; Collet, Bertrand

    2018-02-02

    The utility of molecular response data arising from in-vivo single and repeated measure fish disease-challenge experiments is compared. An in-silico 'experiment' involving the generation of two imaginary immune-molecule quantity response profiles over time for individual animals was carried out. Daily 'observed' molecule quantities were drawn from the 'known' individual response profiles to mimic the results of single and repeated measurement. The results indicate that repeated measure experiments are required to infer individual level response profiles, and that these experiments also provide more accurate summary statistics and data more suited to inferring the dependent ordering of the molecular response. Additionally repeated measure experiments utilise fewer animals than single measure experiments. These results are described alongside a discussion of experimental methodological issues pertinent to the adoption of aquatic animal repeated measure experimental designs. We conclude that investigators need to take particular care when making inferences from single measure experiments and that serious consideration should be given to using repeated measure experiments for in-vivo fish disease-challenge investigations. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  17. Vibration monitoring of a helicopter blade model using the optical fiber distributed strain sensing technique.

    PubMed

    Wada, Daichi; Igawa, Hirotaka; Kasai, Tokio

    2016-09-01

    We demonstrate a dynamic distributed monitoring technique using a long-length fiber Bragg grating (FBG) interrogated by optical frequency domain reflectometry (OFDR) that measures strain at a speed of 150 Hz, spatial resolution of 1 mm, and measurement range of 20 m. A 5 m FBG is bonded to a 5.5 m helicopter blade model, and vibration is applied by the step relaxation method. The time domain responses of the strain distributions are measured, and the blade deflections are calculated based on the strain distributions. Frequency response functions are obtained using the time domain responses of the calculated deflection induced by the preload release, and the modal parameters are retrieved. Experimental results demonstrated the dynamic monitoring performances and the applicability to the modal analysis of the OFDR-FBG technique.

  18. Distinguishing Adolescents With ADHD From Their Unaffected Siblings and Healthy Comparison Subjects by Neural Activation Patterns During Response Inhibition.

    PubMed

    van Rooij, Daan; Hoekstra, Pieter J; Mennes, Maarten; von Rhein, Daniel; Thissen, Andrieke J A M; Heslenfeld, Dirk; Zwiers, Marcel P; Faraone, Stephen V; Oosterlaan, Jaap; Franke, Barbara; Rommelse, Nanda; Buitelaar, Jan K; Hartman, Catharina A

    2015-07-01

    Dysfunctional response inhibition is a key executive function impairment in attention deficit hyperactivity disorder (ADHD). Still, behavioral response inhibition measures do not consistently differentiate affected from unaffected individuals. The authors therefore investigated neural correlates of response inhibition and the familial nature of these neural correlates. Functional MRI measurements of neural activation during the stop-signal task and behavioral measures of response inhibition were obtained in adolescents and young adults with ADHD (N=185), their unaffected siblings (N=111), and healthy comparison subjects (N=124). Stop-signal task reaction times were longer and error rates were higher in participants with ADHD, but not in their unaffected siblings, while reaction time variability was higher in both groups than in comparison subjects. Relative to comparison subjects, participants with ADHD and unaffected siblings had neural hypoactivation in frontal-striatal and frontal-parietal networks, whereby activation in inferior frontal and temporal/parietal nodes in unaffected siblings was intermediate between levels of participants with ADHD and comparison subjects. Furthermore, neural activation in inferior frontal nodes correlated with stop-signal reaction times, and activation in both inferior frontal and temporal/parietal nodes correlated with ADHD severity. Neural activation alterations in ADHD are more robust than behavioral response inhibition deficits and explain variance in response inhibition and ADHD severity. Although only affected participants with ADHD have deficient response inhibition, hypoactivation in inferior frontal and temporal-parietal nodes in unaffected siblings supports the familial nature of the underlying neural process. Activation deficits in these nodes may be useful as endophenotypes that extend beyond the affected individuals in the family.

  19. Measurement of Gust Response on a Turbine Cascade

    NASA Technical Reports Server (NTRS)

    Kurkov, A. P.; Lucci, B. L.

    1995-01-01

    The paper presents benchmark experimental data on a gust response of an annular turbine cascade. The experiment was particularly designed to provide data for comparison with the results of a typical linearized gust-response analysis. Reduced frequency, Mach number, and incidence were varied independently. Except for the lowest reduced frequency, the gust velocity distribution was nearly sinusoidal. For the high inlet-velocity series of tests, the cascade was near choking. The mean flow was documented by measuring blade surface pressures and the cascade exit flow. High-response pressure transducers were used to measure the unsteady pressure distribution. Inlet-velocity components and turbulence parameters were measured using hot wire. In addition to the synchronous time-average pressure spectra, typical power spectra are included for several representative conditions.

  20. Adults' past-day recall of sedentary time: reliability, validity, and responsiveness.

    PubMed

    Clark, Bronwyn K; Winkler, Elisabeth; Healy, Genevieve N; Gardiner, Paul G; Dunstan, David W; Owen, Neville; Reeves, Marina M

    2013-06-01

    Past-day recall rather than recall of past week or a usual/typical day may improve the validity of self-reported sedentary time measures. This study examined the test-retest reliability, criterion validity, and responsiveness of the seven-item questionnaire, Past-day Adults' Sedentary Time (PAST). Participants (breast cancer survivors, n = 90, age = 33-75 yr, body mass index = 25-40 kg·m) in a 6-month randomized controlled trial of a lifestyle-based weight loss intervention completed the interviewer-administered PAST questionnaire about time spent sitting/lying on the previous day for work, transport, television viewing, nonwork computer use, reading, hobbies, and other purposes (summed for total sedentary time). The instrument was administered at baseline, 7 d later for test-retest reliability (n = 86), and at follow-up. ActivPAL3-assessed sit/lie time in bouts of ≥5 min during waking hours on the recall day was used as the validity criterion measure at both baseline (n = 72) and follow-up (n = 68). Analyses included intraclass correlation coefficients, Pearson's correlations (r), and Bland-Altman plots and responsiveness index. The PAST had fair to good test-retest reliability (intraclass correlation coefficient = 0.50, 95% confidence interval [CI] = 0.32-0.64). At baseline, the correlation between PAST and activPAL sit/lie time was r = 0.57 (95% CI = 0.39-0.71). The mean difference between PAST at baseline and retest was -25 min (5.2%), 95% limits of agreement = -5.9 to 5.0 h, and the activPAL sit/lie time was -9 min (1.8%), 95% limits of agreement = -4.9 to 4.6 h. The PAST showed small but significant responsiveness (-0.44, 95% CI = -0.92 to -0.04); responsiveness of activPAL sit/lie time was not significant. The PAST questionnaire provided an easy-to-administer measure of sedentary time in this sample. Validity and reliability findings compare favorably with other sedentary time questionnaires. Past-day recall of sedentary time shows promise for use in future health behavior, epidemiological, and population surveillance studies.

  1. Integrated Temperature and Hydrogen Sensors with MEMS Technology

    PubMed Central

    Jiang, Hongchuan; Huang, Min; Yu, Yibing; Tian, Xiaoyu; Zhang, Wanli; Zhang, Jianfeng; Huang, Yifan; Yu, Kun

    2017-01-01

    In this work, a PdNi thin film hydrogen gas sensor with integrated Pt thin film temperature sensor was designed and fabricated using the micro-electro-mechanical system (MEMS) process. The integrated sensors consist of two resistors: the former, based on Pt film, is used as a temperature sensor, while the latter had the function of hydrogen sensing and is based on PdNi alloy film. The temperature coefficient of resistance (TCR) in both devices was measured and the output response of the PdNi film hydrogen sensor was calibrated based on the temperature acquired by the Pt temperature sensor. The SiN layer was deposited on top of Pt film to inhibit the hydrogen diffusion and reduce consequent disturbance on temperature measurement. The TCR of the PdNi film and the Pt film was about 0.00122/K and 0.00217/K, respectively. The performances of the PdNi film hydrogen sensor were investigated with hydrogen concentrations from 0.3% to 3% on different temperatures from 294.7 to 302.2 K. With the measured temperature of the Pt resistor and the TCR of the PdNi film, the impact of the temperature on the performances of the PdNi film hydrogen sensor was reduced. The output response, response time and recovery time of the PdNi film hydrogen sensors under the hydrogen concentration of 0.5%, 1.0%, 1.5% and 2.0% were measured at 313 K. The output response of the PdNi thin film hydrogen sensors increased with increasing hydrogen concentration while the response time and recovery time decreased. A cycling test between pure nitrogen and 3% hydrogen concentration was performed at 313 K and PdNi thin film hydrogen sensor demonstrated great repeatability in the cycling test. PMID:29301220

  2. Spectral sensitivity of the photointrinsic iris in the red-eared slider turtle (Trachemys scripta elegans).

    PubMed

    Sipe, Grayson O; Dearworth, James R; Selvarajah, Brian P; Blaum, Justin F; Littlefield, Tory E; Fink, Deborah A; Casey, Corinne N; McDougal, David H

    2011-01-01

    Our goal in this study was to examine the red-eared slider turtle for a photomechanical response (PMR) and define its spectral sensitivity. Pupils of enucleated eyes constricted to light by ∼11%, which was one-third the response measured in alert behaving turtles at ∼33%. Rates of constriction in enucleated eyes that were measured by time constants (1.44-3.70 min) were similar to those measured in turtles at 1.97 min. Dilation recovery rates during dark adaptation for enucleated eyes were predicted using line equations and computed times for reaching maximum sizes between 26 and 44 min. Times were comparable to the measures in turtles where maximum pupil size occurred within 40 min and possessed a time constant of 12.78 min. Hill equations were used to derive irradiance threshold values from enucleated hemisected eyes and then plot a spectral sensitivity curve. The analysis of the slopes and maximum responses revealed contribution from at least two different photopigments, one with a peak at 410 nm and another with a peak at 480 nm. Fits by template equations suggest that contractions are triggered by multiple photopigments in the iris including an opsin-based visual pigment and some other novel photopigment, or a cryptochrome with an absorbance spectrum significantly different from that used in our model. In addition to being regulated by retinal feedback via parasympathetic nervous pathways, the results support that the iris musculature is photointrinsically responsive. In the turtle, the control of its direct pupillary light response (dPLR) includes photoreceptive mechanisms occurring both in its iris and in its retina. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Changes in auditory nerve responses across the duration of sinusoidally amplitude-modulated electric pulse-train stimuli.

    PubMed

    Hu, Ning; Miller, Charles A; Abbas, Paul J; Robinson, Barbara K; Woo, Jihwan

    2010-12-01

    Response rates of auditory nerve fibers (ANFs) to electric pulse trains change over time, reflecting substantial spike-rate adaptation that depends on stimulus parameters. We hypothesize that adaptation affects the representation of amplitude-modulated pulse trains used by cochlear prostheses to transmit speech information to the auditory system. We recorded cat ANF responses to sinusoidally amplitude-modulated (SAM) trains with 5,000 pulse/s carriers. Stimuli delivered by a monopolar intracochlear electrode had fixed modulation frequency (100 Hz) and depth (10%). ANF responses were assessed by spike-rate measures, while representation of modulation was evaluated by vector strength (VS) and the fundamental component of the fast Fourier transform (F(0) amplitude). These measures were assessed across the 400 ms duration of pulse-train stimuli, a duration relevant to speech stimuli. Different stimulus levels were explored and responses were categorized into four spike-rate groups to assess level effects across ANFs. The temporal pattern of rate adaptation to modulated trains was similar to that of unmodulated trains, but with less rate adaptation. VS to the modulator increased over time and tended to saturate at lower spike rates, while F(0) amplitude typically decreased over time for low driven rates and increased for higher driven rates. VS at moderate and high spike rates and degree of F(0) amplitude temporal changes at low and moderate spike rates were positively correlated with the degree of rate adaptation. Thus, high-rate carriers will modify the ANF representation of the modulator over time. As the VS and F(0) measures were sensitive to adaptation-related changes over different spike-rate ranges, there is value in assessing both measures.

  4. The Effect of Light-Intensity Cycling on Mood and Working Memory in Response to a Randomized, Placebo-Controlled Design.

    PubMed

    Lindheimer, Jacob B; OʼConnor, Patrick J; McCully, Kevin K; Dishman, Rod K

    Prior attempts to measure psychological responses to exercise are potentially limited by a failure to account for participants' expectations, the absence of a valid exercise placebo, and demand characteristics. The purpose of this study was to explore the main and interactive effects of a manipulation designed to increase expectations about the psychological benefits of an acute bout of active, light-intensity (treatment), and passive (placebo) cycling on mood and cognition. Demand characteristics were attenuated during recruitment, informed consent, and interactions with test administrators by communicating to participants that the study purpose was to assess the effects of active and passive cycling on respiration, heart rate, and muscle activation. A repeated-measures, randomized, placebo-controlled design (n = 60) was used with cycling (active, passive) and information (informed, not informed) as between-subjects factors. State anxiety, feelings of energy, and working memory (percent accuracy and reaction time for correct responses) were measured at baseline (time 1), immediately after cycling (time 2) and 20 minutes after cycling (time 3). Most participants did not guess the purpose of the study (~92%) or expect a reduction in state anxiety (85%) or an increase in energy (80%) or cognitive performance (~93%). Mood and cognitive performance were not improved by active or passive cycling (all p values ≥ .12). The methods used here to disguise the experimental hypotheses provide a potential framework for reducing demand characteristics and placebo responses in future investigations of psychological responses to exercise.

  5. Field camera measurements of gradient and shim impulse responses using frequency sweeps.

    PubMed

    Vannesjo, S Johanna; Dietrich, Benjamin E; Pavan, Matteo; Brunner, David O; Wilm, Bertram J; Barmet, Christoph; Pruessmann, Klaas P

    2014-08-01

    Applications of dynamic shimming require high field fidelity, and characterizing the shim field dynamics is therefore necessary. Modeling the system as linear and time-invariant, the purpose of this work was to measure the impulse response function with optimal sensitivity. Frequency-swept pulses as inputs are analyzed theoretically, showing that the sweep speed is a key factor for the measurement sensitivity. By adjusting the sweep speed it is possible to achieve any prescribed noise profile in the measured system response. Impulse response functions were obtained for the third-order shim system of a 7 Tesla whole-body MR scanner. Measurements of the shim fields were done with a dynamic field camera, yielding also cross-term responses. The measured shim impulse response functions revealed system characteristics such as response bandwidth, eddy currents and specific resonances, possibly of mechanical origin. Field predictions based on the shim characterization were shown to agree well with directly measured fields, also in the cross-terms. Frequency sweeps provide a flexible tool for shim or gradient system characterization. This may prove useful for applications involving dynamic shimming by yielding accurate estimates of the shim fields and a basis for setting shim pre-emphasis. Copyright © 2013 Wiley Periodicals, Inc.

  6. Maritime Evaluation of Aerosol Fire Knock Down Tools. Part 2: Toxicity and Corrosion Potential

    DTIC Science & Technology

    2014-02-01

    determined using paramagnetic sensor technology, while CO and CO2 concentrations were measured, respectively, via gas filter correlation and single...time response of each sensor in the unit. Since it is important to account for this delay in response during analysis and interpretation of measured...within, the compartment as well as confinement and extinguishment of the fire. 1 The initial response of the NOx analyzer and delay in sensor

  7. APD Response Time Measurements for Future TOF-E Systems

    NASA Astrophysics Data System (ADS)

    Starkey, M. J.; Ogasawara, K.; Dayeh, M. A.; Desai, M. I.

    2017-12-01

    In space physics, the ability to detect ions is crucial to understanding plasma distributions in the solar wind. This usually typically requires the determination of the particle's mass, charge, and total energy. Current ion detection schemes are implemented in three sequential parts; an electrostatic analyzer for energy per charge (E/Q) measurements, a time-of-flight (TOF) for mass per charge (M/Q) measurements, and a solid-state detector (SSD) for total energy (E) measurements. Recent work has suggested the use of avalanche photodiode detectors (APD) for a simultaneous TOF and total energy (TOF-E) measurement system, which would replace traditional SSDs, simplify design, and reduce costs. Although TOF based ion spectrometry typically requires timing resolution of <1ns, the timing profile for ion detection by APDs is not well understood. In this study we examine the timing profile of 3 different APDs for ion measurements over a suprathermal energy range of 50-300 keV. The three APDs differ by their doping type (N or P) and their detector thickness (30 μm or 150 μm). We find that APD P30, which is P doped and 30μm thick, provides the fastest rise times of the three APDs. Furthermore, these rise times are species independent and less than 1 ns. Our study shows that APDs are capable of sub-nanosecond response times for low energy ions and thus supports the future use of APDs in replacing SSDs in some TOF-E systems.

  8. Sleep-wake time perception varies by direct or indirect query.

    PubMed

    Alameddine, Y; Ellenbogen, J M; Bianchi, M T

    2015-01-15

    The diagnosis of insomnia rests on self-report of difficulty initiating or maintaining sleep. However, subjective reports may be unreliable, and possibly may vary by the method of inquiry. We investigated this possibility by comparing within-individual response to direct versus indirect time queries after overnight polysomnography. We obtained self-reported sleep-wake times via morning questionnaires in 879 consecutive adult diagnostic polysomnograms. Responses were compared within subjects (direct versus indirect query) and across groups defined by apnea-hypopnea index and by self-reported insomnia symptoms in pre-sleep questionnaires. Direct queries required a time duration response, while indirect queries required clock times from which we calculated time durations. Direct and indirect queries of sleep latency were the same in only 41% of cases, and total sleep time queries matched in only 5.4%. For both latency and total sleep, the most common discrepancy involved the indirect value being larger than the direct response. The discrepancy between direct and indirect queries was not related to objective sleep metrics. The degree of discrepancy was not related to the presence of insomnia symptoms, although patients reporting insomnia symptoms showed underestimation of total sleep duration by direct response. Self-reported sleep latency and total sleep time are often internally inconsistent when comparing direct and indirect survey queries of each measure. These discrepancies represent substantive challenges to effective clinical practice, particularly when diagnosis and management depends on self-reported sleep patterns, as with insomnia. Although self-reported sleep-wake times remains fundamental to clinical practice, objective measures provide clinically relevant adjunctive information. © 2015 American Academy of Sleep Medicine.

  9. Comparisons of methods for determining dominance rank in male and female prairie voles (Microtus ochrogastor)

    USGS Publications Warehouse

    Lanctot, Richard B.; Best, Louis B.

    2000-01-01

    Dominance ranks in male and female prairie voles (Microtus ochrogaster) were determined from 6 measurements that mimicked environmental situations that might be encountered by prairie voles in communal groups, including agonistic interactions resulting from competition for food and water and encounters in burrows. Male and female groups of 6 individuals each were tested against one another in pairwise encounters (i.e., dyads) for 5 of the measurements and together as a group in a 6th measurement. Two types of response variables, aggressive behaviors and possession time of a limiting resource, were collected during trials, and those data were used to determine cardinal ranks and principal component ranks for all animals within each group. Cardinal ranks and principal component ranks seldom yielded similar rankings for each animal across measurements. However, dominance measurements that were conducted in similar environmental contexts, regardless of the response variable recorded, ranked animals similarly. Our results suggest that individual dominance measurements assessed situation- or resource-specific responses. Our study demonstrates problems inherent in determining dominance rankings of individuals within groups, including choosing measurements, response variables, and statistical techniques. Researchers should avoid using a single measurement to represent social dominance until they have first demonstrated that a dominance relationship between 2 individuals has been learned (i.e., subsequent interactions show a reduced response rather than an escalation), that this relationship is relatively constant through time, and that the relationship is not context dependent. Such assessments of dominance status between all dyads then can be used to generate dominance rankings within social groups.

  10. Temporal accommodation response measured by photorefractive accommodation measurement device

    NASA Astrophysics Data System (ADS)

    Song, Byoungsub; Leportier, Thibault; Park, Min-Chul

    2017-02-01

    Although accommodation response plays an important role in the human vision system for perception of distance, some three-dimensional (3D) displays offer depth stimuli regardless of the accommodation response. The consequence is that most observers watching 3D displays have complained about visual fatigue. The measurement of the accommodation response is therefore necessary to develop human-friendly 3D displays. However, only few studies about accommodation measurement have been reported. Most of the investigations have been focused on the measurement and analysis of monocular accommodation responses only because the accommodation response works individually in each eye. Moreover, a main eye perceives dominantly the object distance. However, the binocular accommodation response should be examined because both eyes are used to watch the 3D display in natural conditions. The ophthalmic instrument that we developed enabled to measure changes in the accommodation response of the two eyes simultaneously. Two cameras acquired separately the infrared images reflected from each eyes after the reflected beams passed through a cylindrical lens. The changes in the accommodation response could then be estimated from the changes in the astigmatism ratio of the infrared images that were acquired in real time. In this paper, we compared the accommodation responses of main eye between the monocular and the binocular conditions. The two eyes were measured one by one, with only one eye opened, during measurement for monocular condition. Then the two eyes were examined simultaneously for binocular condition. The results showed similar tendencies for main eye accommodation response in both cases.

  11. Measurement of Responsibility: A Critical Evaluation of Level of Work Measurement by Time-Span of Discretion.

    ERIC Educational Resources Information Center

    Laner, S.; And Others

    This report is a critical evaluation based on extended field trials and theoretical analysis of the time-span technique of measuring level of work in organizational hierarchies. It is broadly concluded that the technique does possess many of the desirable features claimed by its originator, but that earlier, less highly structured versions based…

  12. Short hold times in dynamic vapor sorption measurements mischaracterize the equilibrium moisture content of wood

    Treesearch

    Samuel V. Glass; Charles R. Boardman; Samuel L. Zelinka

    2017-01-01

    Recently, the dynamic vapor sorption (DVS) technique has been used to measure sorption isotherms and develop moisture-mechanics models for wood and cellulosic materials. This method typically involves measuring the time-dependent mass response of a sample following step changes in relative humidity (RH), fitting a kinetic model to the data, and extrapolating the...

  13. In-pile Thermal Conductivity Characterization with Time Resolved Raman

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Xinwei; Hurley, David H.

    The project is designed to achieve three objectives: (1) Develop a novel time resolved Raman technology for direct measurement of fuel and cladding thermal conductivity. (2) Validate and improve the technology development by measuring ceramic materials germane to the nuclear industry. (3) Conduct instrumentation development to integrate optical fiber into our sensing system for eventual in-pile measurement. We have developed three new techniques: time-domain differential Raman (TD-Raman), frequency-resolved Raman (FR-Raman), and energy transport state-resolved Raman (ET-Raman). The TD-Raman varies the laser heating time and does simultaneous Raman thermal probing, the FR-Raman probes the material’s thermal response under periodical laser heatingmore » of different frequencies, and the ET-Raman probes the thermal response under steady and pulsed laser heating. The measurement capacity of these techniques have been fully assessed and verified by measuring micro/nanoscale materials. All these techniques do not need the data of laser absorption and absolute material temperature rise, yet still be able to measure the thermal conductivity and thermal diffusivity with unprecedented accuracy. It is expected they will have broad applications for in-pile thermal characterization of nuclear materials based on pure optical heating and sensing.« less

  14. The Speed of Visual Attention and Motor-Response Decisions in Adult Attention-Deficit/Hyperactivity Disorder.

    PubMed

    Cross-Villasana, Fernando; Finke, Kathrin; Hennig-Fast, Kristina; Kilian, Beate; Wiegand, Iris; Müller, Hermann Joseph; Möller, Hans-Jürgen; Töllner, Thomas

    2015-07-15

    Adults with attention-deficit/hyperactivity disorder (ADHD) exhibit slowed reaction times (RTs) in various attention tasks. The exact origins of this slowing, however, have not been established. Potential candidates are early sensory processes mediating the deployment of focal attention, stimulus response translation processes deciding upon the appropriate motor response, and motor processes generating the response. We combined mental chronometry (RT) measures of adult ADHD (n = 15) and healthy control (n = 15) participants with their lateralized event-related potentials during the performance of a visual search task to differentiate potential sources of slowing at separable levels of processing: the posterior contralateral negativity (PCN) was used to index focal-attentional selection times, while the lateralized readiness potentials synchronized to stimulus and response events were used to index the times taken for response selection and production, respectively. To assess the clinical relevance of event-related potentials, a correlation analysis between neural measures and subjective current and retrospective ADHD symptom ratings was performed. ADHD patients exhibited slower RTs than control participants, which were accompanied by prolonged PCN and lateralized readiness potentials synchronized to stimulus, but not lateralized readiness potentials synchronized to response events, latencies. Moreover, the PCN timing was positively correlated with ADHD symptom ratings. The behavioral RT slowing of adult ADHD patients was based on a summation of internal processing delays arising at perceptual and response selection stages; motor response production, by contrast, was not impaired. The correlation between PCN times and ADHD symptom ratings suggests that this brain signal may serve as a potential candidate for a neurocognitive endophenotype of ADHD. Copyright © 2015 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  15. Capturing the dynamics of response variability in the brain in ADHD.

    PubMed

    van Belle, Janna; van Raalten, Tamar; Bos, Dienke J; Zandbelt, Bram B; Oranje, Bob; Durston, Sarah

    2015-01-01

    ADHD is characterized by increased intra-individual variability in response times during the performance of cognitive tasks. However, little is known about developmental changes in intra-individual variability, and how these changes relate to cognitive performance. Twenty subjects with ADHD aged 7-24 years and 20 age-matched, typically developing controls participated in an fMRI-scan while they performed a go-no-go task. We fit an ex-Gaussian distribution on the response distribution to objectively separate extremely slow responses, related to lapses of attention, from variability on fast responses. We assessed developmental changes in these intra-individual variability measures, and investigated their relation to no-go performance. Results show that the ex-Gaussian measures were better predictors of no-go performance than traditional measures of reaction time. Furthermore, we found between-group differences in the change in ex-Gaussian parameters with age, and their relation to task performance: subjects with ADHD showed age-related decreases in their variability on fast responses (sigma), but not in lapses of attention (tau), whereas control subjects showed a decrease in both measures of variability. For control subjects, but not subjects with ADHD, this age-related reduction in variability was predictive of task performance. This group difference was reflected in neural activation: for typically developing subjects, the age-related decrease in intra-individual variability on fast responses (sigma) predicted activity in the dorsal anterior cingulate gyrus (dACG), whereas for subjects with ADHD, activity in this region was related to improved no-go performance with age, but not to intra-individual variability. These data show that using more sophisticated measures of intra-individual variability allows the capturing of the dynamics of task performance and associated neural changes not permitted by more traditional measures.

  16. Capturing the dynamics of response variability in the brain in ADHD

    PubMed Central

    van Belle, Janna; van Raalten, Tamar; Bos, Dienke J.; Zandbelt, Bram B.; Oranje, Bob; Durston, Sarah

    2014-01-01

    ADHD is characterized by increased intra-individual variability in response times during the performance of cognitive tasks. However, little is known about developmental changes in intra-individual variability, and how these changes relate to cognitive performance. Twenty subjects with ADHD aged 7–24 years and 20 age-matched, typically developing controls participated in an fMRI-scan while they performed a go-no-go task. We fit an ex-Gaussian distribution on the response distribution to objectively separate extremely slow responses, related to lapses of attention, from variability on fast responses. We assessed developmental changes in these intra-individual variability measures, and investigated their relation to no-go performance. Results show that the ex-Gaussian measures were better predictors of no-go performance than traditional measures of reaction time. Furthermore, we found between-group differences in the change in ex-Gaussian parameters with age, and their relation to task performance: subjects with ADHD showed age-related decreases in their variability on fast responses (sigma), but not in lapses of attention (tau), whereas control subjects showed a decrease in both measures of variability. For control subjects, but not subjects with ADHD, this age-related reduction in variability was predictive of task performance. This group difference was reflected in neural activation: for typically developing subjects, the age-related decrease in intra-individual variability on fast responses (sigma) predicted activity in the dorsal anterior cingulate gyrus (dACG), whereas for subjects with ADHD, activity in this region was related to improved no-go performance with age, but not to intra-individual variability. These data show that using more sophisticated measures of intra-individual variability allows the capturing of the dynamics of task performance and associated neural changes not permitted by more traditional measures. PMID:25610775

  17. Situation Awareness Measurement Techniques for Submarine Track Management

    DTIC Science & Technology

    2013-02-22

    efficient performance in work systems as diverse as combat aviation (Vidulich, McCoy, & Crabtree, 1995), anaesthesiology (Gaba, Howard, & Small, 1995), and...between when the experimenter asks the participant whether they were ‘ready’ to the time that the participant accepts the question. Following this, the...SA question is asked and SPAM response time is measured as the time between when the experimenter completes asking the question to the time the

  18. System implications of the ambulance arrival-to-patient contact interval on response interval compliance.

    PubMed

    Campbell, J P; Gratton, M C; Salomone, J A; Lindholm, D J; Watson, W A

    1994-01-01

    In some emergency medical services (EMS) system designs, response time intervals are mandated with monetary penalties for noncompliance. These times are set with the goal of providing rapid, definitive patient care. The time interval of vehicle at scene-to-patient access (VSPA) has been measured, but its effect on response time interval compliance has not been determined. To determine the effect of the VSPA interval on the mandated code 1 (< 9 min) and code 2 (< 13 min) response time interval compliance in an urban, public-utility model system. A prospective, observational study used independent third-party riders to collect the VSPA interval for emergency life-threatening (code 1) and emergency nonlife-threatening (code 2) calls. The VSPA interval was added to the 9-1-1 call-to-dispatch and vehicle dispatch-to-scene intervals to determine the total time interval from call received until paramedic access to the patient (9-1-1 call-to-patient access). Compliance with the mandated response time intervals was determined using the traditional time intervals (9-1-1 call-to-scene) plus the VSPA time intervals (9-1-1 call-to-patient access). Chi-square was used to determine statistical significance. Of the 216 observed calls, 198 were matched to the traditional time intervals. Sixty-three were code 1, and 135 were code 2. Of the code 1 calls, 90.5% were compliant using 9-1-1 call-to-scene intervals dropping to 63.5% using 9-1-1 call-to-patient access intervals (p < 0.0005). Of the code 2 calls, 94.1% were compliant using 9-1-1 call-to-scene intervals. Compliance decreased to 83.7% using 9-1-1 call-to-patient access intervals (p = 0.012). The addition of the VSPA interval to the traditional time intervals impacts system response time compliance. Using 9-1-1 call-to-scene compliance as a basis for measuring system performance underestimates the time for the delivery of definitive care. This must be considered when response time interval compliances are defined.

  19. Faster response time, effective use of resources : integrating transportation systems and emergency management systems.

    DOT National Transportation Integrated Search

    1999-01-01

    When emergency services agencies share : facilities and traffic monitoring resources : with transportation management agencies, : the efficiency and speed of incident : response are measurably improved.

  20. Development of measurement simulation of the laser dew-point hygrometer using an optical fiber cable

    NASA Astrophysics Data System (ADS)

    Matsumoto, Shigeaki

    2005-02-01

    In order to improve the initial and the response times of the Laser Dew-Point Hygrometer (LDH), the measurement simulation was developed on the basis of the loop computation of the surface temperature of a gold plate for dew depostition, the quantity of deposited dew and the intensity of scattered light from the surface of the plate at time interval of 5 sec during measurement. A more detailed relationship between the surface temperature of the plate and the cooling current, and the time constant of the integrator in the control circuit of the LDH were introduced in the simulation program as a function of atmospheric temperature. The simulation was more close to the actual measurement by the LDH. The simulation results indicated the possibility of improving both the times of teh LDH by the increase of the sensitivity of dew and that of the mass transfer coefficient of dew deposited on the plate surface. It was concluded that the initial and the response times could be improved to below 100sec and 120 sec, respectively in the dew-point range at room temperature, that are almost half of the those times of the original LDH.

  1. Measurement and Analysis of Thermal Energy Responses from Discrete Urban Surfaces Using Remote Sensing Data

    NASA Technical Reports Server (NTRS)

    Quattrochi, D. A.; Ridd, M. K.

    1993-01-01

    This study employs data from the airborne Thermal Infrared Multispectral Scanner (TIMS) to measure thermal (i.e., longwave) energy responses, emitted or upwelling, from discrete surfaces that are typical of the city landscape within Salt Lake City, Utah, over a single diurnal time period (i.e., a single day, night-time sequence). These data are used to quantify the disposition of thermal energy for selected urban surfaces during the daytime and night-time, and the amount of change in thermal response or flux recorded between day and night. An analysis is presented on the thermal interrelationships observed for common urban materials for day, night, and flux, as identified from the TIMS data through the delineation of discrete surface type polygons. The results from the study illustrate that such factors as heat capacity, thermal conductivity, and the amount of soil moisture available have a profound impact on the magnitude of thermal energy emanating from a specific surface and on the dynamics of longwave energy response between day and night.

  2. Terahertz dielectric response of photoexcited carriers in Si revealed via single-shot optical-pump and terahertz-probe spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minami, Yasuo; Horiuchi, Kohei; Masuda, Kaisei

    We have demonstrated accurate observations of terahertz (THz) dielectric response due to photoexcited carriers in a Si plate via single-shot optical-pump and THz-probe spectroscopy. In contrast to conventional THz time-domain spectroscopy, this spectroscopic technique allows single-shot detection of the THz response of materials at a given delay time between the pump and THz pulses, thereby sufficiently extending the time interval between the pump pulses. As a result, we can accurately measure the dielectric properties of materials, while avoiding artifacts in the response caused by the accumulation of long-lived photoexcited carriers. Using our single-shot scheme, the transmittance of a Si platemore » was measured in the range of 0.5–2.5 THz with different pump fluences. Based on a Drude model analysis, the optically induced complex dielectric constant, plasma frequency, and damping rate in the THz region were quantitatively evaluated.« less

  3. GADRAS-DRF 18.6 User's Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Horne, Steve M.; Thoreson, Greg G.; Theisen, Lisa A.

    2016-05-01

    The Gamma Detector Response and Analysis Software–Detector Response Function (GADRAS-DRF) application computes the response of gamma-ray and neutron detectors to incoming radiation. This manual provides step-by-step procedures to acquaint new users with the use of the application. The capabilities include characterization of detector response parameters, plotting and viewing measured and computed spectra, analyzing spectra to identify isotopes, and estimating source energy distributions from measured spectra. GADRAS-DRF can compute and provide detector responses quickly and accurately, giving users the ability to obtain usable results in a timely manner (a matter of seconds or minutes).

  4. Teacher and Peer Responsivity to Pro-Social Behaviour of High Aggressors in Preschool

    ERIC Educational Resources Information Center

    McComas, Jennifer J.; Johnson, LeAnne; Symons, Frank J.

    2005-01-01

    Naturally occurring aggressive and pro-social behaviour among 12 preschool children was examined in relation to teacher and peer responsiveness. A standardized real-time direct observational protocol was used in the context of a repeated measures design to measure the frequency and sequences of aggressive and pro-social behaviour of target…

  5. A Test of the Integration of the Hopelessness and Response Styles Theories of Depression in Middle Adolescence

    ERIC Educational Resources Information Center

    Abela, John R. Z.; Parkinson, Carolyn; Stolow, Darren; Starrs, Claire

    2009-01-01

    The current study examined several theories of depression in a sample of middle adolescents. At Time 1, 367 ninth graders completed measures assessing depressogenic inferential styles, the tendency to ruminate in response to depressed mood, and depressive symptoms. Six weeks later, participants completed measures assessing negative events and…

  6. Some Possible Responses to Social Needs from Academia.

    ERIC Educational Resources Information Center

    Congdon, Paul U.

    The University has a 3 part responsibility: academic excellence, research, and community service. This last responsibility tends to get short shrift in most institutions of higher learning, because an institution's excellence is generally not measured by its responsiveness to social needs. Yet, the time has come when higher education must face its…

  7. Objective and automated measurement of dynamic vision functions

    NASA Technical Reports Server (NTRS)

    Flom, M. C.; Adams, A. J.

    1976-01-01

    A phoria stimulus array and electro-oculographic (EOG) arrangements for measuring motor and sensory responses of subjects subjected to stress or drug conditions are described, along with experimental procedures. Heterophoria (as oculomotor function) and glare recovery time (time required for photochemical and neural recovery after exposure to a flash stimulus) are measured, in research aimed at developing automated objective measurement of dynamic vision functions. Onset of involuntary optokinetic nystagmus in subjects attempting to track moving stripes (while viewing through head-mounted binocular eyepieces) after exposure to glare serves as an objective measure of glare recovery time.

  8. Measurement, time-stamping, and analysis of electrodermal activity in fMRI

    NASA Astrophysics Data System (ADS)

    Smyser, Christopher; Grabowski, Thomas J.; Rainville, Pierre; Bechara, Antione; Razavi, Mehrdad; Mehta, Sonya; Eaton, Brent L.; Bolinger, Lizann

    2002-04-01

    A low cost fMRI-compatible system was developed for detecting electrodermal activity without inducing image artifact. Subject electrodermal activity was measured on the plantar surface of the foot using a standard recording circuit. Filtered analog skin conductance responses (SCR) were recorded with a general purpose, time-stamping data acquisition system. A conditioning paradigm involving painful thermal stimulation was used to demonstrate SCR detection and investigate neural correlates of conditioned autonomic activity. 128x128 pixel EPI-BOLD images were acquired with a GE 1.5T Signa scanner. Image analysis was performed using voxel-wise multiple linear regression. The covariate of interest was generated by convolving stimulus event onset with a standard hemodynamic response function. The function was time-shifted to determine optimal activation. Significance was tested using the t-statistic. Image quality was unaffected by the device, and conditioned and unconditioned SCRs were successfully detected. Conditioned SCRs correlated significantly with activity in the right anterior insular cortex. The effect was more robust when responses were scaled by SCR amplitude. The ability to measure and time register SCRs during fMRI acquisition enables studies of cognitive processes marked by autonomic activity, including those involving decision-making, pain, emotion, and addiction.

  9. Simultaneous measurement of time-domain fNIRS and physiological signals during a cognitive task

    NASA Astrophysics Data System (ADS)

    Jelzow, A.; Tachtsidis, I.; Kirilina, E.; Niessing, M.; Brühl, R.; Wabnitz, H.; Heine, A.; Ittermann, B.; Macdonald, R.

    2011-07-01

    Functional near-infrared spectroscopy (fNIRS) is a commonly used technique to measure the cerebral vascular response related to brain activation. It is known that systemic physiological processes, either independent or correlated with the stimulation task, can influence the optical signal making its interpretation challenging. The aim of the present work is to investigate the impact of task-evoked changes in the systemic physiology on fNIRS measurements for a cognitive paradigm. For this purpose we carried out simultaneous measurements of time-domain fNIRS on the forehead and systemic physiological signals, i.e. mean blood pressure, heart rate, respiration, galvanic skin response, scalp blood flow (flux) and red blood cell (RBC) concentration changes. We performed measurements on 15 healthy volunteers during a semantic continuous performance task (CPT). The optical data was analyzed in terms of depth-selective moments of distributions of times of flight of photons through the tissue. In addition, cerebral activation was localized by a subsequent fMRI experiment on the same subject population using the same task. We observed strong non-cerebral task-evoked changes in concentration changes of oxygenated hemoglobin in the forehead. We investigated the temporal behavior and mutual correlations between hemoglobin changes and the systemic processes. Mean blood pressure (BP), galvanic skin response (GSR) and heart rate exhibited significant changes during the activation period, whereby BP and GSR showed the highest correlation with optical measurements.

  10. On the time response of background obtained in γ-ray spectroscopy experiments using LaBr3(Ce) detectors with different shielding

    NASA Astrophysics Data System (ADS)

    Régis, J.-M.; Dannhoff, M.; Jolie, J.; Müller-Gatermann, C.; Saed-Samii, N.

    2016-03-01

    Employing the γ-γ fast-timing technique with LaBr3(Ce) scintillator detectors allows the direct determination of lifetimes of nuclear excited states with a lower limit of about 5 ps. This limit is increased as soon as background is present in the coincidence spectra underneath the full-energy peaks of the γ-γ cascade. Our aim was to identify the components of the γ-ray background by systematic γ-γ fast-timing measurements using different types of γ shielding within a large γ-ray spectrometer. The energy dependent physical zero-time response was measured using background-free full-energy peak events from the 152Eu γ-ray source. This is compared with the time response of the (Compton-) background distribution as obtained using the prompt 60Co γ-ray source. The time response of the typical Compton background is about 15 ps faster than the time response of background-free full-energy peak events. Below about 500 keV, a second type of background contributes by the detection of Compton-scattered γ rays generated in the materials of the spectrometer around the detector. Due to the additional time-of-flight of the Compton-scattered γ rays, this low-energy background is largely delayed. Compared with a bare cylindrical 1.5 in . × 1.5 in . LaBr3(Ce) detector, the BGO-shielded detector in the Compton-suppression mode improves the peak-to-total ratio by a factor of 1.66(5), while the Pb-shielded detector only slightly reduces the low-energy background.

  11. A Further Assessment of Momentary Time-Sampling across Extended Interval Lengths

    ERIC Educational Resources Information Center

    Alvero, Alicia M.; Rappaport, Eva; Taylor, Matthew A.

    2011-01-01

    The current study compared the estimation of momentary time-sampling (MTS) to actual safety performance of three ergonomic responses: back, shoulder, and feet. Actual safety performance was established for the five participants by measuring the target responses with a continuous procedure. MTS 90, 105, 120, 135, 150, 165, 180, 195, 210, 240, and…

  12. What Are the Shapes of Response Time Distributions in Visual Search?

    ERIC Educational Resources Information Center

    Palmer, Evan M.; Horowitz, Todd S.; Torralba, Antonio; Wolfe, Jeremy M.

    2011-01-01

    Many visual search experiments measure response time (RT) as their primary dependent variable. Analyses typically focus on mean (or median) RT. However, given enough data, the RT distribution can be a rich source of information. For this paper, we collected about 500 trials per cell per observer for both target-present and target-absent displays…

  13. Social Reinforcement Delays in Free-Flying Honey Bees (Apis mellifera L.)

    PubMed Central

    Craig, David Philip Arthur; Grice, James W.; Varnon, Chris A.; Gibson, B.; Sokolowski, Michel B. C.; Abramson, Charles I.

    2012-01-01

    Free-flying honey bees (Apis mellifera L.) reactions were observed when presented with varying schedules of post-reinforcement delays of 0 s, 300 s, or 600 s. We measured inter-visit-interval, response length, inter-response-time, and response rate. Honey bees exposed to these post-reinforcement delay intervals exhibit one of several patterns compared to groups not encountering delays, and had longer inter-visit-intervals. We observed no group differences in inter-response time. Honey bees with higher response rates tended to not finish the experiment. The removal of the delay intervals increased response rates for those subjects that completed the trials. PMID:23056425

  14. A Time Domain Impedance Probe For Ultra-Fast Measurements of Electron Parameters in the Ionosphere: Results From A NASA USIP Experiment

    NASA Astrophysics Data System (ADS)

    Clark, D. C.; Spencer, E. A.; Gollapalli, R.; Kerrigan, B.

    2016-12-01

    A plasma impedance probe is used to obtain plasma parameters in the ionosphere by measuring the magnitude, shape and location of resonances in the frequency spectrum when a probe structure is driven with RF excitation. We have designed and developed a new Time Domain Impedance Probe (TDIP) capable of making measurements of absolute electron density and electron neutral collision frequency at temporal and spatial resolutions not previously attained. A single measurement can be made in a time as short as 100 microseconds, which yields much higher spatial resolution than a frequency sweep method. This method essentially consists of applying a small amplitude time limited voltage signal into a probe and measuring the resulting current response. The frequency bandwidth of the voltage signal is selected in order that the electron plasma resonances are observable. A prototype of the new instrument was flown at 08:45 EST on March 1 2016 on a NASA Undergraduate Student Instrument Progam (USIP) sounding rocket launched out of Wallops Flight Facility (Flight time was around 20 minutes). Here we analyze the data from the sounding rocket experiment, using an adaptive system identification technique to compare the measured data with analytical formulas obtained from a theoretical consideration of the time domain response. The analytical formula is calibrated to a plasma fluid finite difference time domain (PFFDTD) numerical computation before using it to analyze the rocket data from 85 km to 170 km on both upleg and downleg. Our results show that the technique works as advertised, but several issues including payload charging and signal rectification remains to be resolved. A plasma impedance probe is used to obtain plasma parameters in the ionosphere by measuring the magnitude, shape and location of resonances in the frequency spectrum when a probe structure is driven with RF excitation. We have designed and developed a new Time Domain Impedance Probe (TDIP) capable of making measurements of absolute electron density and electron neutral collision frequency at temporal and spatial resolutions not previously attained. A single measurement can be made in a time as short as 100 microseconds, which yields much higher spatial resolution than a frequency sweep method. This method essentially consists of applying a small amplitude time limited voltage signal into a probe and measuring the resulting current response. The frequency bandwidth of the voltage signal is selected in order that the electron plasma resonances are observable. A prototype of the new instrument was flown at 08:45 EST on March 1 2016 on a NASA Undergraduate Student Instrument Progam (USIP) sounding rocket launched out of Wallops Flight Facility (Flight time was around 20 minutes). Here we analyze the data from the sounding rocket experiment, using an adaptive system identification technique to compare the measured data with analytical formulas obtained from a theoretical consideration of the time domain response. The analytical formula is calibrated to a plasma fluid finite difference time domain (PFFDTD) numerical computation before using it to analyze the rocket data from 85 km to 170 km on both upleg and downleg. Our results show that the technique works as advertised, but several issues including payload charging and signal rectification remains to be resolved.

  15. Probe shapes that measure time-averaged streamwise momentum and cross-stream turbulence intensity

    NASA Technical Reports Server (NTRS)

    Rossow, Vernon J. (Inventor)

    1993-01-01

    A method and apparatus for directly measuring the time-averaged streamwise momentum in a turbulent stream use a probe which has total head response which varies as the cosine-squared of the angle of incidence. The probe has a nose with a slight indentation on its front face for providing the desired response. The method of making the probe incorporates unique design features. Another probe may be positioned in a side-by-side relationship to the first probe to provide a direct measurement of the total pressure. The difference between the two pressures yields the sum of the squares of the cross-stream components of the turbulence level.

  16. Conditional Dependence between Response Time and Accuracy: An Overview of its Possible Sources and Directions for Distinguishing between Them

    PubMed Central

    Bolsinova, Maria; Tijmstra, Jesper; Molenaar, Dylan; De Boeck, Paul

    2017-01-01

    With the widespread use of computerized tests in educational measurement and cognitive psychology, registration of response times has become feasible in many applications. Considering these response times helps provide a more complete picture of the performance and characteristics of persons beyond what is available based on response accuracy alone. Statistical models such as the hierarchical model (van der Linden, 2007) have been proposed that jointly model response time and accuracy. However, these models make restrictive assumptions about the response processes (RPs) that may not be realistic in practice, such as the assumption that the association between response time and accuracy is fully explained by taking speed and ability into account (conditional independence). Assuming conditional independence forces one to ignore that many relevant individual differences may play a role in the RPs beyond overall speed and ability. In this paper, we critically consider the assumption of conditional independence and the important ways in which it may be violated in practice from a substantive perspective. We consider both conditional dependences that may arise when all persons attempt to solve the items in similar ways (homogeneous RPs) and those that may be due to persons differing in fundamental ways in how they deal with the items (heterogeneous processes). The paper provides an overview of what we can learn from observed conditional dependences. We argue that explaining and modeling these differences in the RPs is crucial to increase both the validity of measurement and our understanding of the relevant RPs. PMID:28261136

  17. Combined Characterization of the Time Response of Impression Materials via Traditional and FTIR Measurements

    PubMed Central

    Derchi, Giacomo; Manca, Enrico; Shayganpour, Amirreza; Barone, Antonio; Diaspro, Alberto; Salerno, Marco

    2015-01-01

    We investigated the temporal response of four dental impression materials, namely three siloxanes (Imprint 4, Flexitime, Aquasil) and one polyether (Impregum). The null hypothesis was that the nominal working times are confirmed by instrumental laboratory tests. We also aimed to identify alternative techniques with strong physical-chemical background for the assessment of temporal response. Traditional characterization was carried out by shark fin test device and durometer at both ambient and body temperature. Additionally, Fourier-transform infrared spectroscopy was performed at room temperature. From shark fin height and Shore hardness versus time the working time and the setting time of the materials were evaluated, respectively. These were in reasonable agreement with the nominal values, except for Impregum, which showed longer working time. Spectroscopy confirmed the different character of the two types of materials, and provided for Imprint 4 and Aquasil an independent evaluation of both evolution times, consistent with the results of the other techniques. Shark fin test and durometer measurements showed deviations in setting time, low sensitivity to temperature for Flexitime, and longer working time at higher temperature for Impregum. Deviations of working time appear in operating conditions from what specified by the manufacturers. Fourier-transform infrared spectroscopy can provide insight in the correlation between material properties and their composition and structure.

  18. Empirical STORM-E Model. [I. Theoretical and Observational Basis

    NASA Technical Reports Server (NTRS)

    Mertens, Christopher J.; Xu, Xiaojing; Bilitza, Dieter; Mlynczak, Martin G.; Russell, James M., III

    2013-01-01

    Auroral nighttime infrared emission observed by the Sounding of the Atmosphere using Broadband Emission Radiometry (SABER) instrument onboard the Thermosphere-Ionosphere-Mesosphere Energetics and Dynamics (TIMED) satellite is used to develop an empirical model of geomagnetic storm enhancements to E-region peak electron densities. The empirical model is called STORM-E and will be incorporated into the 2012 release of the International Reference Ionosphere (IRI). The proxy for characterizing the E-region response to geomagnetic forcing is NO+(v) volume emission rates (VER) derived from the TIMED/SABER 4.3 lm channel limb radiance measurements. The storm-time response of the NO+(v) 4.3 lm VER is sensitive to auroral particle precipitation. A statistical database of storm-time to climatological quiet-time ratios of SABER-observed NO+(v) 4.3 lm VER are fit to widely available geomagnetic indices using the theoretical framework of linear impulse-response theory. The STORM-E model provides a dynamic storm-time correction factor to adjust a known quiescent E-region electron density peak concentration for geomagnetic enhancements due to auroral particle precipitation. Part II of this series describes the explicit development of the empirical storm-time correction factor for E-region peak electron densities, and shows comparisons of E-region electron densities between STORM-E predictions and incoherent scatter radar measurements. In this paper, Part I of the series, the efficacy of using SABER-derived NO+(v) VER as a proxy for the E-region response to solar-geomagnetic disturbances is presented. Furthermore, a detailed description of the algorithms and methodologies used to derive NO+(v) VER from SABER 4.3 lm limb emission measurements is given. Finally, an assessment of key uncertainties in retrieving NO+(v) VER is presented

  19. Response Time Measurements of the NIF DANTE XRD-31 X-Ray Diodes (Pre-print)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Don Pellinen and Michael Griffin

    2009-01-23

    The XRD-31 is a fast, windowless X-ray vacuum photodiode developed by EG&G. It is currently the primary fast X-ray detector used to diagnose the X-rays on NIF and OMEGA on the multichannel DANTE spectrometer. The XRD-31 has a dynamic range of less than 1e-12 amps to more than 10 amps. A technique is described to measure the impulse response of the diodes to a 150 fs pulse of 200 nm laser light and a method to calculate the “risetime” for a square pulse and compare it with the computed electron transit time from the photocathode to the anode. Measured responsemore » time for 5 XRD-31s assembled in early 2004 was 149.7 ps +-2.75 ps.« less

  20. Response time to colored stimuli in the full visual field

    NASA Technical Reports Server (NTRS)

    Haines, R. F.; Dawson, L. M.; Galvan, T.; Reid, L. M.

    1975-01-01

    Peripheral visual response time was measured in seven dark adapted subjects to the onset of small (45' arc diam), brief (50 msec), colored (blue, yellow, green, red) and white stimuli imaged at 72 locations within their binocular field of view. The blue, yellow, and green stimuli were matched for brightness at about 2.6 sub log 10 units above their absolute light threshold, and they appeared at an unexpected time and location. These data were obtained to provide response time and no-response data for use in various design disciplines involving instrument panel layout. The results indicated that the retina possesses relatively concentric regions within each of which mean response time can be expected to be of approximately the same duration. These regions are centered near the fovea and extend farther horizontally than vertically. Mean foveal response time was fastest for yellow and slowest for blue. Three and one-half percent of the total 56,410 trials presented resulted in no-responses. Regardless of stimulus color, the lowest percentage of no-responses occurred within 30 deg arc from the fovea and the highest within 40 deg to 80 deg arc below the fovea.

  1. A window on perception: Response times of odontocete cetaceans in audiometric tests

    NASA Astrophysics Data System (ADS)

    Blackwood, Diane J.; Ridgway, Sam H.; Evans, William E.

    2002-05-01

    A standard psychometric measurement is response time, the interval elapsing between a stimulus and a response. While studies of response time have been published for humans and other terrestrial mammals, this study marks the first report of response times for odontocete cetaceans at threshold in an audiometric task. Two white whales (Delphinapterus leucas) and four Atlantic bottlenose dolphins (Tursiops truncatus) were given audiometric tests to determine masked hearing thresholds. Animals were tested at 26 frequencies over a range from 200 Hz to 100 kHz using pure tones. The test tone amplitudes covered a range of 20 dB re 1 microPascal including the hearing threshold of the animal at that frequency. Hearing thresholds varied from 87.5 dB to 125.5 dB depending on frequency, masking noise intensity and individual animal. Data was analyzed to determine characteristic relationships between response time and amplitude of test tone for each frequency and animal. The two whales responded significantly slower (640 ms, 0.001) than the four dolphins (430 ms). As in terrestrial animals, reaction time became shorter as stimulus strength increased. At threshold, median response time across frequencies within each animal varied about 150 ms.

  2. Innovations in Rheometer Controlled-Rate Control Loop Design: Ultra Low Angular Speed Control and New Applications

    NASA Astrophysics Data System (ADS)

    Schulz, Ulrich; Sierro, Philippe; Nijman, Jint

    2008-07-01

    The design and implementation of an angular speed control loop for a universal rheometer is not a trivial task. The combination of a highly dynamic, very low inertia (drag cup) motor (motor inertia is 10-5 kg m2) with samples which can range in viscosity from 10-3 Pas to 108 Pas, which can be between purely viscous and higly viscoelastic, which can exhibit yield-stresses, etc. asks for a highly adaptive digital control loop. For the HAAKE MARS rotational rheometer a new adaptive control loop was developed which allows the control of angular speeds as low 5×10-9 rad/s and response times a short as 10 ms. The adaptation of the control loop to "difficult" samples is performed by analysing the response of the complete system to a short pre-test. In this paper we will show that the (very) short response times at (very) low angular speeds are not only achieved with ideal samples, but due to the adaptable control loop, also with "difficult" samples. We will show measurement results on "difficult" samples like cosmetic creams and emulsions, a laponite gel, etc. to proof that angular speeds down to 10-4 rad/s are reached within 10 ms to 20 ms and angular speeds down to 10-7 rad/s within 1 s to 2 s. The response times for reaching ultra low angular speeds down to 5×10-9 rad/s are in the order of 10 s to 30 s. With this new control loop it is, for the first time, possible to measure yield stresses by applying a very low constant shear-rate to the sample and measuring the torque response as a function of time.

  3. Urban sprawl and delayed ambulance arrival in the U.S.

    PubMed

    Trowbridge, Matthew J; Gurka, Matthew J; O'Connor, Robert E

    2009-11-01

    Minimizing emergency medical service (EMS) response time is a central objective of prehospital care, yet the potential influence of built environment features such as urban sprawl on EMS system performance is often not considered. This study measures the association between urban sprawl and EMS response time to test the hypothesis that features of sprawling development increase the probability of delayed ambulance arrival. In 2008, EMS response times for 43,424 motor-vehicle crashes were obtained from the Fatal Analysis Reporting System, a national census of crashes involving > or =1 fatality. Sprawl at each crash location was measured using a continuous county-level index previously developed by Ewing et al. The association between sprawl and the probability of a delayed ambulance arrival (> or =8 minutes) was then measured using generalized linear mixed modeling to account for correlation among crashes from the same county. Urban sprawl is significantly associated with increased EMS response time and a higher probability of delayed ambulance arrival (p=0.03). This probability increases quadratically as the severity of sprawl increases while controlling for nighttime crash occurrence, road conditions, and presence of construction. For example, in sprawling counties (e.g., Fayette County GA), the probability of a delayed ambulance arrival for daytime crashes in dry conditions without construction was 69% (95% CI=66%, 72%) compared with 31% (95% CI=28%, 35%) in counties with prominent smart-growth characteristics (e.g., Delaware County PA). Urban sprawl is significantly associated with increased EMS response time and a higher probability of delayed ambulance arrival following motor-vehicle crashes in the U.S. The results of this study suggest that promotion of community design and development that follows smart-growth principles and regulates urban sprawl may improve EMS performance and reliability.

  4. Responsiveness of the Test of Basic Motor Skills of Children with Down Syndrome.

    PubMed

    van den Heuvel, Marieke E; de Jong, Inge; Lauteslager, Peter E M; Volman, M J M

    2009-01-01

    The aim of this study was to examine the responsiveness of the Test of Basic Motor Skills for Children with Down Syndrome (BMS). Forty-one children with Down Syndrome, 3 to 36 months of age, participated in the study. Gross motor skills were assessed three times using the BMS and the Gross Motor Function Measure (GMFM) before and after a baseline period of 2 weeks (T1-T2) and after a period of 16 weeks (T2-T3). Internal and external responsiveness of the BMS was analyzed using Guyatt's Responsiveness Index (GRI) and 2 x 2 repeated measures. Change in BMS scores was compared to change in GMFM scores and parent and physiotherapist ratings of change. The responsiveness of the BMS was large (GRI = 2.55). A significant Time x Age interaction [F(1,37) = 8.87, p < .01] indicated that BMS scores increased more for children

  5. Effects of repeated Valsalva maneuver straining on cardiac and vasoconstrictive baroreflex responses

    NASA Technical Reports Server (NTRS)

    Convertino, Victor A.; Ratliff, Duane A.; Doerr, Donald F.; Ludwig, David A.; Muniz, Gary W.; Benedetti, Erik; Chavarria, Jose; Koreen, Susan; Nguyen, Claude; Wang, Jeff

    2003-01-01

    INTRODUCTION: We hypothesized that repeated respiratory straining maneuvers (repeated SM) designed to elevate arterial BPs (arterial baroreceptor loading) would acutely increase baroreflex responses. METHODS: We tested this hypothesis by measuring cardiac baroreflex responses to carotid baroreceptor stimulation (neck pressures), and changes in heart rate and diastolic BP after reductions in BP induced by a 15-s Valsalva maneuver in 10 female and 10 male subjects at 1, 3, 6, and 24 h after performing repeated SM. Baroreflex responses were also measured in each subject at 1, 3, 6, and 24 h at the same time on a separate day without repeated SM (control) in a randomized, counter-balanced cross-over experimental design. RESULTS: There was no statistical difference in carotid-cardiac and peripheral vascular baroreflex responses measured across time following repeated SM compared with the control condition. Integrated cardiac baroreflex response (deltaHR/ deltaSBP) measured during performance of a Valsalva maneuver was increased by approximately 50% to 1.1 +/- 0.2 bpm x mm Hg(-1) at 1 h and 1.0 +/- 0.1 bpm x mm Hg(-1) at 3 h following repeated SM compared with the control condition (0.7 +/- 0.1 bpm x mm Hg(-1) at both 1 and 3 h, respectively). However, integrated cardiac baroreflex response after repeated SM returned to control levels at 6 and 24 h after training. These responses did not differ between men and women. CONCLUSIONS: Our results are consistent with the notion that arterial baroreceptor loading induced by repeated SM increased aortic, but not carotid, cardiac baroreflex responses for as long as 3 h after repeated SM. We conclude that repeated SM increases cardiac baroreflex responsiveness which may provide patients, astronauts, and high-performance aircraft pilots with protection from development of orthostatic hypotension.

  6. Temperature Insensitivity and Behavioural Reduction of the Physiological Stress Response to Longline Capture by the Gummy Shark, Mustelus antarcticus

    PubMed Central

    Guida, Leonardo; Walker, Terence I.; Reina, Richard D.

    2016-01-01

    Many factors influence the physiological stress response to fisheries capture in elasmobranchs. However, the influence of sea surface temperatures (SST) and behaviour are unknown and crucial considering global fishing pressures. We investigated the effect of SST and behaviour on the physiological stress response to capture of the gummy shark, Mustelus antarcticus, and compared our results to a laboratory study using similar conditions to test whether stress responses of in situ capture are consistent with those from laboratory simulations. Capture time for 23 M. antarcticus ranged 32–241 min as measured by hook timers or time depth recorders (TDR) in SSTs ranging 12–20°C. TDR data from 13 M. antarcticus were analysed to quantify capture behaviour as the percentage of time spent moving during capture. Several physiological variables measured from blood samples obtained immediately upon the animals’ landing indicated that although warmer SSTs increased metabolic rate, the stress response to capture was not exacerbated by capture duration. During capture movement occurred for an average of 10% of the time and since M. antarcticus can respire whilst stationary, restricted movement probably mitigated potential influences of increased SSTs and capture duration on the stress response. Previous laboratory findings were also shown to be indicative of in situ conditions and we thus advise that studies control for water temperature given the influence it has on variables (e.g. lactate) used to measure capture stress in elasmobranchs. We highlight the importance of seasonal water temperatures and capture behaviour when assessing the resilience to fisheries capture and the implementation of appropriate fisheries management strategies. PMID:26886126

  7. Understanding Customer Dissatisfaction with Underutilized Distributed File Servers

    NASA Technical Reports Server (NTRS)

    Riedel, Erik; Gibson, Garth

    1996-01-01

    An important trend in the design of storage subsystems is a move toward direct network attachment. Network-attached storage offers the opportunity to off-load distributed file system functionality from dedicated file server machines and execute many requests directly at the storage devices. For this strategy to lead to better performance, as perceived by users, the response time of distributed operations must improve. In this paper we analyze measurements of an Andrew file system (AFS) server that we recently upgraded in an effort to improve client performance in our laboratory. While the original server's overall utilization was only about 3%, we show how burst loads were sufficiently intense to lead to period of poor response time significant enough to trigger customer dissatisfaction. In particular, we show how, after adjusting for network load and traffic to non-project servers, 50% of the variation in client response time was explained by variation in server central processing unit (CPU) use. That is, clients saw long response times in large part because the server was often over-utilized when it was used at all. Using these measures, we see that off-loading file server work in a network-attached storage architecture has to potential to benefit user response time. Computational power in such a system scales directly with storage capacity, so the slowdown during burst period should be reduced.

  8. A behavioral window on the mind of the market: an application of the response time paradigm.

    PubMed

    Mast, Fred W; Zaltman, Gerald

    2005-11-15

    This article focuses on the role of implicit knowledge consumers have about particular brands, products or names. The major findings of several studies, conducted at the Mind of the Market Laboratory at Harvard Business School, are presented with specific emphasis on studies in which response time measurements were the core method. The results revealed that implicit measures provide a rich understanding of the meaning conveyed by a product or brand. Moreover, there is also considerable evidence that implicit measures may be better than traditional explicit measures as predictors of consumer behavior. We discuss the implications for the study of consumer behavior and the importance of combining several methods including neuroimaging, which has received recent attention by marketers, economists and social scientists.

  9. Methods of measurement for semiconductor materials, process control, and devices

    NASA Technical Reports Server (NTRS)

    Bullis, W. M. (Editor)

    1972-01-01

    Significant accomplishments include development of a procedure to correct for the substantial differences of transistor delay time as measured with different instruments or with the same instrument at different frequencies; association of infrared response spectra of poor quality germanium gamma ray detectors with spectra of detectors fabricated from portions of a good crystal that had been degraded in known ways; and confirmation of the excellent quality and cosmetic appearance of ultrasonic bonds made with aluminum ribbon wire. Work is continuing on measurement of resistivity of semiconductor crystals; study of gold-doped silicon, development of the infrared response technique; evaluation of wire bonds and die attachment; and measurement of thermal properties of semiconductor devices, delay time and related carrier transport properties in junction devices, and noise properties of microwave diodes.

  10. Characterization of multi-dye pressure-sensitive microbeads

    NASA Astrophysics Data System (ADS)

    Lacroix, Daniel; Viraye-Chevalier, Teddy; Seiter, Guillaume; Howard, Jonathan; Dabiri, Dana; Khalil, Gamal E.; Xia, Younan; Zhu, Cun

    2013-11-01

    The response times of pressure-sensitive particles to passing shockwaves were measured to investigate their ability to accurately determine pressure changes in unsteady flows. The particles tested were loaded with novel pressure-sensitive dyes such as Pt (II) meso-tetra(pentafluorophenyl)porphine, Pt(II) octaethylporphine, bis(3,5-difluoro-2-(2-pyridyl)phenyl-(2-carboxypyridyl))iridium III, and iridium(III) bis(4-phenylthieno[3,2-c] pyridinato-N,C2')acetylacetonate. For this work, porous silicon dioxide pressure-sensitive beads (PSBeads) were used. Two synthetic procedures were used to fabricate the particles. In the first, a one-step method loaded dyes during the synthesis of microbeads, in the second a two-step method synthesized the microbeads first, then loaded the dyes. The shock tube facility was used to measure the response times of microbeads to fast pressure jumps. The study involved testing multiple luminophors loaded in microbeads with various size distributions. Response times for the silica-based microbeads ranged between 26 μs and 462 μs (at 90% of the amplitude response), which are much faster than previously reported polystyrene-based microbead response times, which range from 507 μs to 1582 μs (at 90% of the amplitude response) [F. Kimura, M. Rodriguez, J. McCann, B. Carlson, D. Dabiri, G. Khalil, J. B. Callis, Y. Xia, and M. Gouterman, "Development and characterization of fast responding pressure sensitive microspheres," Rev. Sci. Instrum. 79, 074102 (2008)].

  11. Performance Measures in Out-of-School Time Evaluation. Out-of-School Time Evaluation Snapshot, Number 3.

    ERIC Educational Resources Information Center

    Harvard University Harvard Family Research Project, 2004

    2004-01-01

    Increasingly, out-of-school time programs are being asked to provide data that documents their progress and demonstrates their results. But for many OST programs and their over-worked staff this added responsibility is the "straw that broke the camel?s back." Across the country there is a cry from programs for help in deciding what to measure and…

  12. Sensitivity, reliability and the effects of diurnal variation on a test battery of field usable upper limb fatigue measures.

    PubMed

    Yung, Marcus; Wells, Richard P

    2017-07-01

    Fatigue has been linked to deficits in production quality and productivity and, if of long duration, work-related musculoskeletal disorders. It may thus be a useful risk indicator and design and evaluation tool. However, there is limited information on the test-retest reliability, the sensitivity and the effects of diurnal fluctuation on field usable fatigue measures. This study reports on an evaluation of 11 measurement tools and their 14 parameters. Eight measures were found to have test-retest ICC values greater than 0.8. Four measures were particularly responsive during an intermittent fatiguing condition. However, two responsive measures demonstrated rhythmic behaviour, with significant time effects from 08:00 to mid-afternoon and early evening. Action tremor, muscle mechanomyography and perceived fatigue were found to be most reliable and most responsive; but additional analytical considerations might be required when interpreting daylong responses of MMG and action tremor. Practitioner Summary: This paper presents findings from test-retest and daylong reliability and responsiveness evaluations of 11 fatigue measures. This paper suggests that action tremor, muscle mechanomyography and perceived fatigue were most reliable and most responsive. However, mechanomyography and action tremor may be susceptible to diurnal changes.

  13. The importance of measuring growth in response to intervention models: Testing a core assumption✩

    PubMed Central

    Schatschneider, Christopher; Wagner, Richard K.; Crawford, Elizabeth C.

    2011-01-01

    A core assumption of response to instruction or intervention (RTI) models is the importance of measuring growth in achievement over time in response to effective instruction or intervention. Many RTI models actively monitor growth for identifying individuals who need different levels of intervention. A large-scale (N=23,438), two-year longitudinal study of first grade children was carried out to compare the predictive validity of measures of achievement status, growth in achievement, and their combination for predicting future reading achievement. The results indicate that under typical conditions, measures of growth do not make a contribution to prediction that is independent of measures of achievement status. These results question the validity of a core assumption of RTI models. PMID:22224065

  14. An investigation of the validity of six measures of physical function in people awaiting joint replacement surgery of the hip or knee.

    PubMed

    Gill, Stephen D; de Morton, Natalie A; Mc Burney, Helen

    2012-10-01

    To assess and compare the validity of six physical function measures in people awaiting hip or knee joint replacement. Eighty-two people awaiting hip or knee replacement were assessed using six physical function measures including the WOMAC Function scale, SF-36 Physical Function scale, SF-36 Physical Component Summary scale, Patient Specific Functional Scale, 30-second chair stand test, and 50-foot timed walk. Validity was assessed using a head-to-head comparison design. Convergent validity was demonstrated with significant correlations between most measures (Spearman's rho 0.22 to 0.71). The Patient Specific Functional Scale had the lowest correlations with other measures of physical function. Discriminant validity was demonstrated with low correlations between mental health and physical function scores (Spearman's rho -0.12 to 0.33). Only the WOMAC Function scale, 30-second chair stand test, and 50-foot timed walk demonstrated known groups validity when scores for participants who walked with a gait aid were compared with those who did not. Standardized response means and Guyatt's responsiveness indexes indicated that the SF-36 was the least responsive measure. For those awaiting joint replacement surgery of the hip or knee, the current investigation found that the WOMAC Function scale, 30-second chair stand test, and 50-foot timed walk demonstrated the most evidence of validity. The Patient Specific Functional Scale might complement other measures by capturing a different aspect of physical function.

  15. Evidence for age-related changes to temporal attention and memory from the choice time production task

    PubMed Central

    Gooch, Cynthia M.; Stern, Yaakov; Rakitin, Brian C.

    2009-01-01

    The effect of aging on interval timing was examined using a choice time production task, which required participants to choose a key response based on the location of the stimulus, but to delay responding until after a learned time interval. Experiment 1 varied attentional demands of the response choice portion of the task by varying difficulty of stimulus-response mapping. Choice difficulty affected temporal accuracy equally in both age groups, but older participants’ response latencies were more variable under more difficult response choice conditions. Experiment 2 tested the contribution of long-term memory to differences in choice time production between age groups over 3 days of testing. Direction of errors in time production between the two age groups diverged over the 3 sessions, but variability did not differ. Results from each experiment separately show age-related changes to attention and memory in temporal processing using different measures and manipulations in the same task. PMID:19132578

  16. The Effect of Time on Word Learning: An Examination of Decay of the Memory Trace and Vocal Rehearsal in Children with and without Specific Language Impairment

    ERIC Educational Resources Information Center

    Alt, Mary; Spaulding, Tammie

    2011-01-01

    Purpose: The purpose of this study was to measure the effect of time to response in a fast-mapping word learning task for children with specific language impairment (SLI) and children with typically developing language skills (TD). Manipulating time to response allows us to examine decay of the memory trace, the use of vocal rehearsal, and their…

  17. Non-Ideal Compressible-Fluid Dynamics of Fast-Response Pressure Probes for Unsteady Flow Measurements in Turbomachinery

    NASA Astrophysics Data System (ADS)

    Gori, G.; Molesini, P.; Persico, G.; Guardone, A.

    2017-03-01

    The dynamic response of pressure probes for unsteady flow measurements in turbomachinery is investigated numerically for fluids operating in non-ideal thermodynamic conditions, which are relevant for e.g. Organic Rankine Cycles (ORC) and super-critical CO2 applications. The step response of a fast-response pressure probe is investigated numerically in order to assess the expected time response when operating in the non-ideal fluid regime. Numerical simulations are carried out exploiting the Non-Ideal Compressible Fluid-Dynamics (NICFD) solver embedded in the open-source fluid dynamics code SU2. The computational framework is assessed against available experimental data for air in dilute conditions. Then, polytropic ideal gas (PIG), i.e. constant specific heats, and Peng-Robinson Stryjek-Vera (PRSV) models are applied to simulate the flow field within the probe operating with siloxane fluid octamethyltrisiloxane (MDM). The step responses are found to depend mainly on the speed of sound of the working fluid, indicating that molecular complexity plays a major role in determining the promptness of the measurement devices. According to the PRSV model, non-ideal effects can increase the step response time with respect to the acoustic theory predictions. The fundamental derivative of gas-dynamic is confirmed to be the driving parameter for evaluating non-ideal thermodynamic effects related to the dynamic calibration of fast-response aerodynamic pressure probes.

  18. High-resolution measurement of DMS and volatile organic compounds dissolved in seawater using equilibrator inlet-proton transfer reaction-mass spectrometry (EI-PTR-MS)

    NASA Astrophysics Data System (ADS)

    Kameyama, S.; Tanimoto, H.; Inomata, S.; Tsunogai, U.; Ooki, A.; Yokouchi, Y.; Takeda, S.; Obata, H.; Tsuda, A.; Uematsu, M.

    2010-12-01

    We developed an equilibrator inlet-proton transfer reaction-mass spectrometry (EI-PTR-MS) for high-resolution measurement of multiple volatile organic compounds (VOCs) dissolved in seawater. The equilibration of six VOC species (dimethyl sulfide (DMS), isoprene, propene, acetone, acetaldehyde, and methanol) between seawater and carrier gas, and the response time of the system were evaluated in the laboratory. While isoprene and propene are not in equilibrium associated with slow response time (≈ 15 min) due to low solubility, other species achieve complete equilibrium with overall response time within 2 min under the condition without water droplets on the inner wall of the headspace of the equilibrator. The EI-PTR-MS instrument was deployed during a cruise in the western North Pacific. For DMS and isoprene, comparison of EI-PTR-MS with a membrane tube equilibrator-gas chromatography/mass spectrometry was made, showing generally good agreement. EI-PTR-MS captured temporal variations of dissolved VOCs including small-scale variability, demonstrating the performance of EI-PTR-MS technique for continuous measurement of multiple VOCs in seawater.

  19. Design and analysis of fractional order seismic transducer for displacement and acceleration measurements

    NASA Astrophysics Data System (ADS)

    Veeraian, Parthasarathi; Gandhi, Uma; Mangalanathan, Umapathy

    2018-04-01

    Seismic transducers are widely used for measurement of displacement, velocity, and acceleration. This paper presents the design of seismic transducer in the fractional domain for the measurement of displacement and acceleration. The fractional order transfer function for seismic displacement and acceleration transducer are derived using Grünwald-Letnikov derivative. Frequency response analysis of fractional order seismic displacement transducer (FOSDT) and fractional order seismic acceleration transducer (FOSAT) are carried out for different damping ratio with the different fractional order, and the maximum dynamic measurement range is identified. The results demonstrate that fractional order seismic transducer has increased dynamic measurement range and less phase distortion as compared to the conventional seismic transducer even with a lower damping ratio. Time response of FOSDT and FOSAT are derived analytically in terms of Mittag-Leffler function, the effect of fractional behavior in the time domain is evaluated from the impulse and step response. The fractional order system is found to have significantly reduced overshoot as compared to the conventional transducer. The fractional order seismic transducer design proposed in this paper is illustrated with a design example for FOSDT and FOSAT. Finally, an electrical equivalent of FOSDT and FOSAT is considered, and its frequency response is found to be in close agreement with the proposed fractional order seismic transducer.

  20. The hydrological response of a rocky head water basin to convective rainfalls

    NASA Astrophysics Data System (ADS)

    Gregoretti, Carlo; Bernard, Martino; Degetto, Massimo; Matteo, Berti; Alessandro, Simoni; Stefano, Lanzoni

    2015-04-01

    A sharp-crested weir is installed at the outlet (altitude 1770 m a.s.l) of a rocky channel incised on the walls of Dimai Peak in the area of Fiames (Cortina d'Ampezzo, Dolomites-North Eastern Italian Alps) at the purpose of measuring runoff discharges. The area of the headwater basin is just 0.032 km2 but sub-vertical cliffs are capable to generate notable discharge during severe rainstorms. Due to the severe environment only five runoff events were measured (two times the facility was destroyed by rock falls and avalanches; other times failure of sensors stopped the measurements). Hydrological response is characterized by peaked hydrographs with very high rising limb. A kinematic distributed hydrological model was used to simulate the response of the basin to the convective rainfalls with the help of two rain gauges placed upstream the basin head and downstream the outlet respectively. The hydrological model uses an hortonian simplified law for determining excess rainfall and satisfactorily simulates the measured hydrographs. Such measurements are important for the understanding the hydrological response of a rocky basin to a convective rainfall. Their modeling are important as well when focused on predicting both flash floods in mountain torrents and the triggering conditions and magnitude of runoff generated debris flows.

  1. Neural activation patterns during response inhibition distinguish adolescents with ADHD, their unaffected siblings, and healthy controls

    PubMed Central

    van Rooij, Daan; Hoekstra, Pieter J.; Mennes, Maarten; von Rhein, Daniel; Thissen, Andrieke J.A.M.; Heslenfeld, Dirk; Zwiers, Marcel P.; Faraone, Stephen V.; Oosterlaan, Jaap; Franke, Barbara; Rommelse, Nanda; Buitelaar, Jan K.; Hartman, Catharina A.

    2015-01-01

    Objective Impaired response inhibition is a key executive function deficit of attention-deficit/hyperactivity disorder (ADHD). Still, behavioral response inhibition measures do not consistently differentiate individuals with ADHD from unaffected individuals. We therefore investigated the neural correlates of response inhibition as well as the familial nature of these neural correlates. Methods fMRI measurements of neural activation during the stop-signal task along with behavioral measures of response inhibition were obtained in adolescents and young adults with ADHD (N=185), their unaffected siblings (N=111), and healthy controls (N=124). Results Stop-signal reaction times were longer in participants with ADHD, but not in their unaffected siblings, while reaction time variability and error rates were higher in both groups than in controls. Neural hypoactivation was observed in frontal-striatal and frontal-parietal networks of participants with ADHD and unaffected siblings compared to controls, whereby activation in inferior frontal and temporal/parietal nodes in unaffected siblings was intermediate between that of participants with ADHD and controls. Furthermore, neural activation in inferior frontal nodes correlated with stop-signal reaction times, and activation in both inferior frontal and temporal/parietal nodes correlated with ADHD severity. Conclusions Neural activation alterations in ADHD are more robust than behavioral response inhibition deficits and explain variance in response inhibition and ADHD severity. Although only affected participants with ADHD have deficient response inhibition, hypoactivation in inferior frontal and temporal-parietal nodes in unaffected siblings support the familial nature of the underlying neural process. Hypoactivation in these nodes may be useful as endophenotypes that extend beyond the affected individuals in the family. PMID:25615565

  2. Use of plant woody species electrical potential for irrigation scheduling

    PubMed Central

    Ríos-Rojas, Liliana; Morales-Moraga, David; Alcalde, José A; Gurovich, Luis A

    2015-01-01

    The electrical response of plants to environmental stimuli can be measured and quantitatively related to the intensity of several stimulating sources, like temperature, solar radiation, soil water content, evapotranspiration rates, sap flow and dendrometric cycles. These relations can be used to assess the influence of different environmental situations on soil water availability to plants, defined as a steady state condition between leaf transpirative flow and soil water flow to plant roots. A restricted soil water flow due to soil dryness can trigger water stress in plants, if the atmospheric evaporative demand is high, causing partial stomata closure as a physiological response to avoid plant dehydration; water stressed and unstressed plants manifest a differential electrical response. Real time plant electrical response measurements can anticipate actions that prevent the plant reaching actual stress conditions, optimizing stomata gas exchange and photosynthetic rates. An electrophysiological sensor developed in this work, allows remote real-time recording information on plant electrical potential (EP) in the field, which is highly related to EP measurements obtained with a laboratory Keithley voltmeter sensor used in an highly controlled experimental setup. Our electrophysiological sensor is a wireless, autonomous devise, which transmits EP information via Internet to a data server. Using both types of sensors (EP electrodes with a Keithley voltmeter and the electrophysiological sensor), we measured in real time the electrical responses of Persea americana and Prunus domestica plants, to induced water deficits. The differential response for 2 scenarios: irrigation and water restriction is identified by a progressive change in slope on the daily maximal and minimal electric signal values in stressed plants, and a zero-slope for similar signals for well-watered plants. Results show a correspondence between measured signals obtained by our electrophysiological sensor and the EP electrodes connected to the Keithley voltmeter in each irrigation stage. Also, both sensors show a daily cyclical signal (circadian cycle). PMID:25826257

  3. Use of plant woody species electrical potential for irrigation scheduling.

    PubMed

    Ríos-Rojas, Liliana; Morales-Moraga, David; Alcalde, José A; Gurovich, Luis A

    2015-01-01

    The electrical response of plants to environmental stimuli can be measured and quantitatively related to the intensity of several stimulating sources, like temperature, solar radiation, soil water content, evapotranspiration rates, sap flow and dendrometric cycles. These relations can be used to assess the influence of different environmental situations on soil water availability to plants, defined as a steady state condition between leaf transpirative flow and soil water flow to plant roots. A restricted soil water flow due to soil dryness can trigger water stress in plants, if the atmospheric evaporative demand is high, causing partial stomata closure as a physiological response to avoid plant dehydration; water stressed and unstressed plants manifest a differential electrical response. Real time plant electrical response measurements can anticipate actions that prevent the plant reaching actual stress conditions, optimizing stomata gas exchange and photosynthetic rates. An electrophysiological sensor developed in this work, allows remote real-time recording information on plant electrical potential (EP) in the field, which is highly related to EP measurements obtained with a laboratory Keithley voltmeter sensor used in an highly controlled experimental setup. Our electrophysiological sensor is a wireless, autonomous devise, which transmits EP information via Internet to a data server. Using both types of sensors (EP electrodes with a Keithley voltmeter and the electrophysiological sensor), we measured in real time the electrical responses of Persea americana and Prunus domestica plants, to induced water deficits. The differential response for 2 scenarios: irrigation and water restriction is identified by a progressive change in slope on the daily maximal and minimal electric signal values in stressed plants, and a zero-slope for similar signals for well-watered plants. Results show a correspondence between measured signals obtained by our electrophysiological sensor and the EP electrodes connected to the Keithley voltmeter in each irrigation stage. Also, both sensors show a daily cyclical signal (circadian cycle).

  4. Response Assessment in Paediatric Phase I Trials According to RECIST Guidelines: Survival Outcomes, Patterns of Progression and Relevance of Changes in Tumour Measurements.

    PubMed

    Carceller, Fernando; Bautista, Francisco J; Fowkes, Lucy A; Marshall, Lynley V; Sirvent, Sara I; Chisholm, Julia C; Pearson, Andrew D J; Koh, Dow-Mu; Moreno, Lucas

    2016-08-01

    RECIST guidelines constitute the reference for radiological response assessment in most paediatric trials of anticancer agents. However, these criteria have not been validated in children. We evaluated the outcomes and patterns of progression of children/adolescents enrolled in phase I trials in two paediatric drug development units. Patients aged ≤21 assessed with RECIST (v1.0 or v1.1) were eligible. Clinico-radiological data were analysed using Mann-Whitney U and log-rank tests to correlate response categories and sum of longest diameters (SLD) with time-to-event variables and overall survival (OS). Sixty-one patients (71 enrolments) were evaluated; median age: 12.7 years (range, 3.1-20.9). Overall, 7% achieved complete/partial response (n = 5) and 31% disease stabilisation (n = 22). Median (95% CI) OS (in months) was 29.1 (27.6-30.6) with complete/partial response, 8.9 (2.0-15.8) with stable disease and 2.8 (2.3-3.3) with disease progression (P < 0.001); 32.6% patients with measurable disease presented exclusive progression of existing non-target lesions and/or new lesions. The change in SLD at best response showed a linear correlation with duration of response (r = -0.605; P = 0.004) and time on trial (r = -0.61; P = 0.003), but the change in SLD at progression did not correlate with time to progression (r = -0.219; P = 0.206). Response assessment according to RECIST correlated with OS in children/adolescents treated on phase I trials. The reduction in SLD at best response correlated with more prolonged responses. Tumour size did not constitute an optimal method to assess disease progression in one third of patients with measurable disease. Further refinement of current response assessment guidelines will enable the development of paediatric-specific radiological criteria. © 2016 Wiley Periodicals, Inc.

  5. A Response Function Approach for Rapid Far-Field Tsunami Forecasting

    NASA Astrophysics Data System (ADS)

    Tolkova, Elena; Nicolsky, Dmitry; Wang, Dailin

    2017-08-01

    Predicting tsunami impacts at remote coasts largely relies on tsunami en-route measurements in an open ocean. In this work, these measurements are used to generate instant tsunami predictions in deep water and near the coast. The predictions are generated as a response or a combination of responses to one or more tsunameters, with each response obtained as a convolution of real-time tsunameter measurements and a pre-computed pulse response function (PRF). Practical implementation of this method requires tables of PRFs in a 3D parameter space: earthquake location-tsunameter-forecasted site. Examples of hindcasting the 2010 Chilean and the 2011 Tohoku-Oki tsunamis along the US West Coast and beyond demonstrated high accuracy of the suggested technology in application to trans-Pacific seismically generated tsunamis.

  6. Explicit and Implicit Verbal Response Inhibition in Preschool-Age Children Who Stutter.

    PubMed

    Anderson, Julie D; Wagovich, Stacy A

    2017-04-14

    The purpose of this study was to examine (a) explicit and implicit verbal response inhibition in preschool children who do stutter (CWS) and do not stutter (CWNS) and (b) the relationship between response inhibition and language skills. Participants were 41 CWS and 41 CWNS between the ages of 3;1 and 6;1 (years;months). Explicit verbal response inhibition was measured using a computerized version of the grass-snow task (Carlson & Moses, 2001), and implicit verbal response inhibition was measured using the baa-meow task. Main dependent variables were reaction time and accuracy. The CWS were significantly less accurate than the CWNS on the implicit task, but not the explicit task. The CWS also exhibited slower reaction times than the CWNS on both tasks. Between-group differences in performance could not be attributed to working memory demands. Overall, children's performance on the inhibition tasks corresponded with parents' perceptions of their children's inhibition skills in daily life. CWS are less effective and efficient than CWNS in suppressing a dominant response while executing a conflicting response in the verbal domain.

  7. Explicit and Implicit Verbal Response Inhibition in Preschool-Age Children Who Stutter

    PubMed Central

    Wagovich, Stacy A.

    2017-01-01

    Purpose The purpose of this study was to examine (a) explicit and implicit verbal response inhibition in preschool children who do stutter (CWS) and do not stutter (CWNS) and (b) the relationship between response inhibition and language skills. Method Participants were 41 CWS and 41 CWNS between the ages of 3;1 and 6;1 (years;months). Explicit verbal response inhibition was measured using a computerized version of the grass–snow task (Carlson & Moses, 2001), and implicit verbal response inhibition was measured using the baa–meow task. Main dependent variables were reaction time and accuracy. Results The CWS were significantly less accurate than the CWNS on the implicit task, but not the explicit task. The CWS also exhibited slower reaction times than the CWNS on both tasks. Between-group differences in performance could not be attributed to working memory demands. Overall, children's performance on the inhibition tasks corresponded with parents' perceptions of their children's inhibition skills in daily life. Conclusions CWS are less effective and efficient than CWNS in suppressing a dominant response while executing a conflicting response in the verbal domain. PMID:28384673

  8. Response moderation models for conditional dependence between response time and response accuracy.

    PubMed

    Bolsinova, Maria; Tijmstra, Jesper; Molenaar, Dylan

    2017-05-01

    It is becoming more feasible and common to register response times in the application of psychometric tests. Researchers thus have the opportunity to jointly model response accuracy and response time, which provides users with more relevant information. The most common choice is to use the hierarchical model (van der Linden, 2007, Psychometrika, 72, 287), which assumes conditional independence between response time and accuracy, given a person's speed and ability. However, this assumption may be violated in practice if, for example, persons vary their speed or differ in their response strategies, leading to conditional dependence between response time and accuracy and confounding measurement. We propose six nested hierarchical models for response time and accuracy that allow for conditional dependence, and discuss their relationship to existing models. Unlike existing approaches, the proposed hierarchical models allow for various forms of conditional dependence in the model and allow the effect of continuous residual response time on response accuracy to be item-specific, person-specific, or both. Estimation procedures for the models are proposed, as well as two information criteria that can be used for model selection. Parameter recovery and usefulness of the information criteria are investigated using simulation, indicating that the procedure works well and is likely to select the appropriate model. Two empirical applications are discussed to illustrate the different types of conditional dependence that may occur in practice and how these can be captured using the proposed hierarchical models. © 2016 The British Psychological Society.

  9. Using Network Science Measures to Predict the Lexical Decision Performance of Adults Who Stutter.

    PubMed

    Castro, Nichol; Pelczarski, Kristin M; Vitevitch, Michael S

    2017-07-12

    Methods from network science have examined various aspects of language processing. Clinical populations may also benefit from these novel analyses. Phonological and lexical factors have been examined in adults who stutter (AWS) as potential contributing factors to stuttering, although differences reported are often subtle. We reexamined the performance of AWS and adults who do not stutter (AWNS) from a previously conducted lexical decision task in an attempt to determine if network science measures would provide additional insight into the phonological network of AWS beyond traditional psycholinguistic measures. Multiple regression was used to examine the influence of several traditional psycholinguistic measures as well as several new measures from network science on response times. AWS responded to low-frequency words more slowly than AWNS; responses for both groups were equivalent for high-frequency words. AWS responded to shorter words more slowly than AWNS, producing a reverse word-length effect. For the network measures, degree/neighborhood density and closeness centrality, but not whether a word was inside or outside the giant component, influenced response times similarly between groups. Network analyses suggest that multiple levels of the phonological network might influence phonological processing, not just the micro-level traditionally considered by mainstream psycholinguistics.

  10. Effect of Mg doping in the gas-sensing performance of RF-sputtered ZnO thin films

    NASA Astrophysics Data System (ADS)

    Vinoth, E.; Gowrishankar, S.; Gopalakrishnan, N.

    2018-06-01

    Thin films of Mg-free and Mg-doped (3, 10 and 20 mol%) ZnO thin films have been deposited on Si (100) substrates by RF magnetron sputtering for gas-sensing application. Preferential orientation along (002) plane with hexagonal wurtzite structure has been observed in X-ray diffraction analysis. The conductivity, resistivity, and mobility of the deposited films have been measured by Hall effect measurement. The bandgap of the films has been calculated from the UV-Vis-NIR spectroscopy. It has been found that the bandgap was increased from 3.35 to 3.91 eV with Mg content in ZnO due to the radiative recombination of excitons. The change in morphology of the grown films has been investigated by scanning electron microscope. Gas-sensing measurements have been conducted for fabricated films. The sensor response, selectivity, and stability measurement were done for the fabricated films. Though better response was found towards ethanol, methanol, and ammonia for MZ2 (Mg at 10 mol%) film and maximum gas response was observed towards ammonia. The selectivity measurement reveals maximum sensitivity about 42% for ammonia. The low response time of 123 s and recovery time of 152 s towards ammonia were observed for MZ2 (Mg at 10 mol%). Stability of the Mg-doped ZnO thin film confirmed by the continuous sensing measurements for 4 months.

  11. Real-time hostile attribution measurement and aggression in children.

    PubMed

    Yaros, Anna; Lochman, John E; Rosenbaum, Jill; Jimenez-Camargo, Luis Alberto

    2014-01-01

    Hostile attributions are an important predictor of aggression in children, but few studies have measured hostile attributions as they occur in real-time. The current study uses an interactive video racing game to measure hostile attributions while children played against a presumed peer. A sample of 75 children, ages 10-13, used nonverbal and verbal procedures to respond to ambiguous provocation by their opponent. Hostile attributions were significantly positively related to parent-rated reactive aggression, when controlling for proactive aggression. Hostile attributions using a nonverbal response procedure were negatively related to proactive aggression, when controlling for reactive aggression. Results suggest hostile attributions in real-time occur quickly and simultaneously with social interaction, which differs from the deliberative, controlled appraisals measured with vignette-based instruments. The relation between real-time hostile attributions and reactive aggression could be accounted for by the impulsive response style that is characteristic of reactive aggression, whereas children exhibiting proactive aggression may be more deliberate and intentional in their responding, resulting in a negative relation with real-time hostile attributions. These findings can be used both to identify children at risk for aggression and to enhance preventive interventions. © 2014 Wiley Periodicals, Inc.

  12. Emotional Responses during Reading: Physiological Responses Predict Real-Time Reading Comprehension

    ERIC Educational Resources Information Center

    Daley, Samantha G.; Willett, John B.; Fischer, Kurt W.

    2014-01-01

    This study investigated the relationship between emotional responses and reading performance in middle-school students. Although a large number of prior studies have investigated the relationship between emotion and reading, those studies have concentrated primarily on relatively static and distal measures of emotion. In this research, we measured…

  13. Electronic mail was not better than postal mail for surveying residents and faculty.

    PubMed

    Akl, Elie A; Maroun, Nancy; Klocke, Robert A; Montori, Victor; Schünemann, Holger J

    2005-04-01

    To compare response rate, time to response, and data quality of electronic and postal surveys in the setting of postgraduate medical education. A randomized controlled trial in a university-based internal medicine residency program. We randomized 119 residents and 83 faculty to an electronic versus a postal survey with up to two reminders and measured response rate, time to response, and data quality. For residents, the e-survey resulted in a lower response rate than the postal survey (63.3% versus 79.7%; difference -16.3%, 95% confidence interval (95% CI) -32.3% to -0.4%%; P=.049), but a shorter mean response time, by 3.8 days (95% CI 0.2-7.4; P=.042). For faculty, the e-survey did not result in a significantly lower response rate than the postal survey (85.4% vs. 81.0%; difference 4.4%, 95% CI -11.7 to 20.5%; P=.591), but resulted in a shorter average response time, by 8.4 days (95% CI 4.4 to 12.4; P < 0.001). There were no differences in the quality of data or responses to the survey between the two methods. E-surveys were not superior to postal surveys in terms of response rate, but resulted in shorter time to response and equivalent data quality.

  14. Responses to Targets in the Visual Periphery in Deaf and Normal-Hearing Adults

    ERIC Educational Resources Information Center

    Rothpletz, Ann M.; Ashmead, Daniel H.; Tharpe, Anne Marie

    2003-01-01

    The purpose of this study was to compare the response times of deaf and normal-hearing individuals to the onset of target events in the visual periphery in distracting and nondistracting conditions. Visual reaction times to peripheral targets placed at 3 eccentricities to the left and right of a center fixation point were measured in prelingually…

  15. "I Think I Can, but I'm Afraid to Try": The Role of Self-Efficacy Beliefs and Mathematics Anxiety in Mathematics Problem-Solving Efficiency

    ERIC Educational Resources Information Center

    Hoffman, Bobby

    2010-01-01

    This study investigated the role of self-efficacy beliefs, mathematics anxiety, and working memory capacity in problem-solving accuracy, response time, and efficiency (the ratio of problem-solving accuracy to response time). Pre-service teachers completed a mathematics anxiety inventory measuring cognitive and affective dispositions for…

  16. Temporal dynamics of lactate concentration in the human brain during acute inspiratory hypoxia

    PubMed Central

    Harris, Ashley D; Roberton, Victoria H; Huckle, Danielle L; Saxena, Neeraj; Evans, C John; Murphy, Kevin; Hall, Judith E; Bailey, Damian M; Mitsis, Georgios; Edden, Richard A E; Wise, Richard G

    2012-01-01

    Purpose To demonstrate the feasibility of measuring the temporal dynamics of cerebral lactate concentration and examine these dynamics in human subjects using MRS during hypoxia. Methods A respiratory protocol consisting of 10 min baseline normoxia, 20 min inspiratory hypoxia and ending with 10 min normoxic recovery was used, throughout which lactate-edited MRS was performed. This was repeated four times in three subjects. A separate session was performed to measure blood lactate. Impulse response functions using end-tidal oxygen and blood lactate as system inputs and cerebral lactate as the system output were examined to describe the dynamics of the cerebral lactate response to a hypoxic challenge. Results The average lactate increase was 20%±15% during the last half of the hypoxic challenge. Significant changes in cerebral lactate concentration were observed after 400s. The average relative increase in blood lactate was 188%±95%. The temporal dynamics of cerebral lactate concentration was reproducibly demonstrated with 200s time bins of MRS data (coefficient of variation 0.063±0.035 between time bins in normoxia). The across subject coefficient of variation was 0.333. Conclusions The methods for measuring the dynamics of the cerebral lactate response developed here would be useful to further investigate the brain’s response to hypoxia. PMID:23197421

  17. Eye movements as a function of response contingencies measured by blackout technique1

    PubMed Central

    Doran, Judith; Holland, James G.

    1971-01-01

    A program may have a low error rate but, at the same time, require little of the student and teach him little. A measure to supplement error rate in evaluating a program has recently been developed. This measure, called the blackout ratio, is the percentage of material that may be deleted without increasing the error rate. In high blackout-ratio programs, obtaining a correct answer is contingent upon only a small portion of the item. The present study determined if such low response-contingent material is read less thoroughly than programmed material that is heavily response-contingent. Eye movements were compared for two versions of the same program that differed only in the choice of the omitted words. The alteration of the required responses resulted in a version with a higher blackout ratio than the original version, which had a low blackout ratio. Eighteen undergraduates received half their material from the high and half their material from the low blackout-ratio version. The order was counterbalanced. Location and duration of all eye fixations in each item were recorded by a Mackworth Eye Marker Camera. On high blackout-ratio material, subjects used fewer fixations, shorter fixation time, and shorter scanning time. High blackout-ratio material failed to evoke the students' attention. PMID:16795275

  18. The tonic immobility test: Do wild and captive golden mantella frogs (Mantella aurantiaca) have the same response?

    PubMed

    Passos, Luiza Figueiredo; Garcia, Gerardo; Young, Robert John

    2017-01-01

    Adaptations to captivity that reduce fitness are one of many reasons, which explain the low success rate of reintroductions. One way of testing this hypothesis is to compare an important behavioural response in captive and wild members of the same species. Thanatosis, is an anti-predator strategy that reduces the risk of death from predation, which is a common behavioral response in frogs. The study subjects for this investigation were captive and wild populations of Mantella aurantiaca. Thanatosis reaction was measured using the Tonic Immobility (TI) test, a method that consists of placing a frog on its back, restraining it in this position for a short period of time and then releasing it and measuring how much time was spent feigning death. To understand the pattern of reaction time, morphometric data were also collected as body condition can affect the duration of thanatosis. The significantly different TI times found in this study, one captive population with shorter responses, were principally an effect of body condition rather than being a result of rearing environment. However, this does not mean that we can always dismiss the importance of rearing environment in terms of behavioural skills expressed.

  19. Three-dimensional ultrasonography of the breast; An adequate replacement for MRI in neoadjuvant chemotherapy tumour response evaluation? - RESPONDER trial.

    PubMed

    van Egdom, L S E; Lagendijk, M; Heijkoop, E H M; Koning, A H J; van Deurzen, C H M; Jager, A; van Lankeren, W; Koppert, L B

    2018-07-01

    Accurate measurement of tumour response during and after neoadjuvant chemotherapy (NAC) is important and may influence treatment decisions in invasive breast cancer patients. Breast MRI forms the gold standard but is more burdensome, time consuming and costly. In this study response measurement was done with 3-D ultrasound by Automated Breast Volume Scanner (ABVS) and compared to breast MRI. Moreover, patient satisfaction with both techniques was compared. A single-institution, prospective observational pilot study evaluating tumour response by ABVS in addition to breast MRI (standard care) was performed in 25 invasive breast cancer patients receiving NAC. Tumour response was evaluated comparing longest tumour diameters as well as tumour volumes at predefined time points using Bland-Altman analysis. Volume measurements for breast MRI were obtained using a fully immersive virtual reality system (a Barco I-Space) and V-Scope software. Same software was used to obtain ABVS volume measurements using an in-house developed desktop VR system. Inter- and intra-observer agreement was evaluated by Intraclass Correlation Coefficient (ICC). Twenty-five patients were eligible for baseline measurement, 20 for a mid-NAC response evaluation, and five for a post-NAC response evaluation. MRI and ABVS showed absolute concordance in 73% of patients for the mid-NAC evaluation, with a 'good' correlation for the difference in longest diameter measurement (ICC 0.73, p < 0.01) as compared to baseline assessment. Concerning difference in volume measurement in the mid-NAC response evaluation showed a 'fair' correlation (ICC 0.52, p < 0.01) and in the post-NAC response evaluation an 'excellent' correlation (ICC 0.98, p < 0.01). 'Excellent' inter- and intra-observer agreement was found (ICC 0.88, p < 0.01) with comparable limits of agreement (LOA) for observer 1 and 2 in both diameter and volume measurement. Patient satisfaction was higher for ABVS compared to breast MRI, 93% versus 12% respectively. ABVS showed 'good' correlation with MRI tumour response evaluation in breast cancer patients during NAC with 'excellent' inter- and intra-observer agreement. ABVS has patients' preference over breast MRI and could be considered as alternative to breast MRI, in case results on an on-going prospective trial confirm these results (NTR6799). Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Dynamic surface acoustic response to a thermal expansion source on an anisotropic half space.

    PubMed

    Zhao, Peng; Zhao, Ji-Cheng; Weaver, Richard

    2013-05-01

    The surface displacement response to a distributed thermal expansion source is solved using the reciprocity principle. By convolving the strain Green's function with the thermal stress field created by an ultrafast laser illumination, the complete surface displacement on an anisotropic half space induced by laser absorption is calculated in the time domain. This solution applies to the near field surface displacement due to pulse laser absorption. The solution is validated by performing ultrafast laser pump-probe measurements and showing very good agreement between the measured time-dependent probe beam deflection and the computed surface displacement.

  1. Verifying the Performance of RTDs in Nuclear Power Plants

    NASA Astrophysics Data System (ADS)

    Hashemian, H. M.

    2003-09-01

    This paper describes a number of techniques that have been developed for nuclear power plants to ensure that optimum steady-state and transient performance is achieved with the resistance temperature detectors (RTDs) that are used in the plant for critical temperature measurements. This includes precision laboratory calibration of RTDs, the Loop Current Step Response (LCSR) method for in-situ response time measurements, a cross calibration technique to verify the steady-state performance of RTDs as installed in the plant, and the Time Domain Reflectometry (TDR) test that is used to identify the location of a problem along RTD cables.

  2. Lawsuit lead time prediction: Comparison of data mining techniques based on categorical response variable.

    PubMed

    Gruginskie, Lúcia Adriana Dos Santos; Vaccaro, Guilherme Luís Roehe

    2018-01-01

    The quality of the judicial system of a country can be verified by the overall length time of lawsuits, or the lead time. When the lead time is excessive, a country's economy can be affected, leading to the adoption of measures such as the creation of the Saturn Center in Europe. Although there are performance indicators to measure the lead time of lawsuits, the analysis and the fit of prediction models are still underdeveloped themes in the literature. To contribute to this subject, this article compares different prediction models according to their accuracy, sensitivity, specificity, precision, and F1 measure. The database used was from TRF4-the Tribunal Regional Federal da 4a Região-a federal court in southern Brazil, corresponding to the 2nd Instance civil lawsuits completed in 2016. The models were fitted using support vector machine, naive Bayes, random forests, and neural network approaches with categorical predictor variables. The lead time of the 2nd Instance judgment was selected as the response variable measured in days and categorized in bands. The comparison among the models showed that the support vector machine and random forest approaches produced measurements that were superior to those of the other models. The evaluation of the models was made using k-fold cross-validation similar to that applied to the test models.

  3. Development of a real-time transport performance optimization methodology

    NASA Technical Reports Server (NTRS)

    Gilyard, Glenn

    1996-01-01

    The practical application of real-time performance optimization is addressed (using a wide-body transport simulation) based on real-time measurements and calculation of incremental drag from forced response maneuvers. Various controller combinations can be envisioned although this study used symmetric outboard aileron and stabilizer. The approach is based on navigation instrumentation and other measurements found on state-of-the-art transports. This information is used to calculate winds and angle of attack. Thrust is estimated from a representative engine model as a function of measured variables. The lift and drag equations are then used to calculate lift and drag coefficients. An expression for drag coefficient, which is a function of parasite drag, induced drag, and aileron drag, is solved from forced excitation response data. Estimates of the parasite drag, curvature of the aileron drag variation, and minimum drag aileron position are produced. Minimum drag is then obtained by repositioning the symmetric aileron. Simulation results are also presented which evaluate the affects of measurement bias and resolution.

  4. Transient Response of Superconducting Microbridges to Supercritical Currents.

    DTIC Science & Technology

    1983-06-01

    KEY WMORS (Conitnue an revers. ide It necee.ary and Ide.ntfy by block umi. ) Time-resolved measurements voltage waveforms phase slip center...nonequilibrium superconductivity theory 10. ABSTRACT (Coninue a Faoed *#do it nocassety and identify by block ewher) We have made time-resolved measurements ... measurements were made on indium microbridges and represent an important extension of the work of Pals and Wolter (1979) to a higher critical temperature

  5. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.; Taylor,Bryant D.; Shams, Qamar A.; Fox, Robert L.

    2007-01-01

    This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

  6. Comparing Individual Differences in Inconsistency and Plasticity as Predictors of Cognitive Function in Older Adults

    PubMed Central

    Grand, Jacob H.G.; Stawski, Robert S.; MacDonald, Stuart W.S.

    2016-01-01

    Introduction Recent theorizing differentiates key constraints on cognition, including one’s current range of processing efficiency (i.e., flexibility or inconsistency) as well as the capacity to expand flexibility over time (i.e., plasticity). The present study uses intensive assessment of response time data to examine the interplay between markers of intraindividual variability (inconsistency) and gains across biweekly retest sessions (plasticity) in relation to age-related cognitive function. Method Participants included 304 adults (aged 64 to 92 years: M=74.02, SD=5.95) from Project MIND, a longitudinal burst design study assessing performance across micro and macro intervals (response latency trials, weekly bursts, annual retests). For two reaction time measures (choice RT and one-back choice RT), baseline measures of response time (RT) inconsistency (intraindividual standard deviation (ISD) across-trials at the first testing session) and plasticity (within-person performance gains in average RT across the 5 biweekly burst sessions) were computed, and then employed in linear mixed models as predictors of individual differences in cognitive function and longitudinal (6 year) rates of cognitive change. Results Independent of chronological age and years of education, higher RT inconsistency was associated uniformly with poorer cognitive function at baseline and with increased cognitive decline for measures of episodic memory and crystallized verbal ability. In contrast, predictive associations for plasticity were more modest for baseline cognitive function and were absent for 6-year cognitive change. Conclusions These findings underscore the potential utility of response times for articulating inconsistency and plasticity as dynamic predictors of cognitive function in older adults. PMID:26898536

  7. Method and system for improved resolution of a compensated calorimeter detector

    DOEpatents

    Dawson, John W.

    1991-01-01

    An improved method and system for a depleted uranium calorimeter detector used in high energy physics experiments. In a depleted uranium calorimeter detector, the energy of a particle entering the calorimeter detector is determined and the output response of the calorimeter detector is compensated so that the ratio of the integrated response of the calorimeter detector from a lepton to the integrated response of the calorimeter detector from a hadron of the same energy as the lepton is approximately equal to 1. In the present invention, the energy of a particle entering the calorimeter detector is determined as a function of time and the hadron content of the response of the calorimeter detector is inferred based upon the time structure of the energy pulse measured by the calorimeter detector. The energy measurement can be corrected based on the inference of the hadron content whereby the resolution of the calorimeter can be improved.

  8. Harnessing naturally occurring data to measure the response of spending to income

    PubMed Central

    Gelman, Michael; Kariv, Shachar; Shapiro, Matthew D.; Silverman, Dan; Tadelis, Steven

    2016-01-01

    This paper presents a new data infrastructure for measuring economic activity. The infrastructure records transactions and account balances, yielding measurements with scope and accuracy that have little precedent in economics. The data are drawn from a diverse population that overrepresents males and younger adults but contains large numbers of underrepresented groups. The data infrastructure permits evaluation of a benchmark theory in economics that predicts that individuals should use a combination of cash management, saving, and borrowing to make the timing of income irrelevant for the timing of spending. As in previous studies and in contrast to the predictions of the theory, there is a response of spending to the arrival of anticipated income. The data also show, however, that this apparent excess sensitivity of spending results largely from the coincident timing of regular income and regular spending. The remaining excess sensitivity is concentrated among individuals with less liquidity. PMID:25013075

  9. A comparison of visual inspection time measures in children with cerebral palsy.

    PubMed

    Kaufman, Jacqueline N; Donders, Jacobus; Warschausky, Seth

    2014-05-01

    This study examined the performance of children with and without cerebral palsy on two inspection time (IT) tests, as accessible nonspeeded response measures of cognitive processing speed. Participants, ages 8 to 16, included 66 children with congenital CP and 119 typically developing peers. Measures were two visual IT tasks with identical target stimuli but differential response strategies either via a traditional dual-key method or with an assistive technology pressure switch interface and response option scanning. The CP group had slower IT than the control group independent of test version. Log transformations were used to address skew, and transformed mean intraclass correlations showed moderate agreement between test versions for both participant groups. Bland-Altman plots showed that at higher mean IT thresholds, greater discrepancies between test version scores were observed. Findings support the feasibility of developing tests that reduce speeded motor response demands. Future test development should incorporate increased gradations of difficulty at the extremes of neuropsychological functioning to more accurately assess the performance of individuals whose conditions are associated with atypical performance levels. (c) 2014 APA, all rights reserved.

  10. Reusable Floating-Electrode Sensor for Real-Time Electrophysiological Monitoring of Nonadherent Cells

    NASA Astrophysics Data System (ADS)

    Pham Ba, Viet Anh; Ta, Van-Thao; Park, Juhun; Park, Eun Jin; Hong, Seunghun

    2015-03-01

    We herein report the development of a reusable floating-electrode sensor (FES) based on aligned single-walled carbon nanotubes, which allowed quantitatively monitoring the electrophysiological responses from nonadherent cells. The FES was used to measure the real-time responses of normal lung cells and small-cell lung cancer (SCLC) cells to the addition of nicotine. The SCLC cells exhibited rather large electrophysiological responses to nicotine compared to normal cells, which was attributed to the overexpressed nicotinic acetylcholine receptors (nAChRs) in the SCLC cells. Importantly, using only a single device could measure repeatedly the responses of multiple individual cells to various drugs, enabling statistically meaningful measurements without errors from the device-to-device variations of the sensor characteristics. As results, that the treatment with drugs such as genistin or daidzein reduced Ca2+ influx in SCLC cells was found. Moreover, tamoxifen, has been known as an anti-estrogen compound, was found to only partly block the binding of daidzein to nAChRs. Our FES can be a promising tool for various biomedical applications such as drug screening and therapy monitoring.

  11. Analysis of electrically evoked compound action potential of the auditory nerve in children with bilateral cochlear implants.

    PubMed

    Caldas, Fernanda Ferreira; Cardoso, Carolina Costa; Barreto, Monique Antunes de Souza Chelminski; Teixeira, Marina Santos; Hilgenberg, Anacléia Melo da Silva; Serra, Lucieny Silva Martins; Bahmad Junior, Fayez

    2016-01-01

    The cochlear implant device has the capacity to measure the electrically evoked compound action potential of the auditory nerve. The neural response telemetry is used in order to measure the electrically evoked compound action potential of the auditory nerve. To analyze the electrically evoked compound action potential, through the neural response telemetry, in children with bilateral cochlear implants. This is an analytical, prospective, longitudinal, historical cohort study. Six children, aged 1-4 years, with bilateral cochlear implant were assessed at five different intervals during their first year of cochlear implant use. There were significant differences in follow-up time (p=0.0082) and electrode position (p=0.0019) in the T-NRT measure. There was a significant difference in the interaction between time of follow-up and electrode position (p=0.0143) when measuring the N1-P1 wave amplitude between the three electrodes at each time of follow-up. The electrically evoked compound action potential measurement using neural response telemetry in children with bilateral cochlear implants during the first year of follow-up was effective in demonstrating the synchronized bilateral development of the peripheral auditory pathways in the studied population. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  12. Response time of mitochondrial oxygen consumption following stepwise changes in cardiac energy demand.

    PubMed

    van Beek, J H; Westerhof, N

    1990-01-01

    We determined the speed with which mitochondrial oxygen consumption and therefore the mitochondrial ATP-synthesis adapted to changes in metabolic demand in the rabbit heart. This was done by measuring the oxygen uptake of the whole heart during a stepwise change in heart rate and correcting for the time taken by diffusion and by convective transport in the blood vessels. Data for the correction for transport time were obtained from the response of venous oxygen concentration to a stepwise change of arterial oxygen concentration. The time constant of the response of mitochondrial oxygen consumption to a step change in heart rate was found to be 4-8 s.

  13. Granzyme B ELISPOT assay to measure influenza-specific cellular immunity.

    PubMed

    Salk, Hannah M; Haralambieva, Iana H; Ovsyannikova, Inna G; Goergen, Krista M; Poland, Gregory A

    2013-12-15

    The immunogenicity and efficacy of influenza vaccination are markedly lower in the elderly. Granzyme B (GrzB), quantified in fresh cell lysates, has been suggested to be a marker of cytotoxic T lymphocyte (CTL) response and a predictor of influenza illness among vaccinated older individuals. We have developed an influenza-specific GrzB ELISPOT assay using cryopreserved PBMCs. This method was tested on 106 healthy older subjects (ages 50-74) at baseline (Day 0) and three additional time points post-vaccination (Day 3, Day 28, Day 75) with influenza A/H1N1-containing vaccine. No significant difference was seen in GrzB response between any of the time points, although influenza-specific GrzB response appears to be elevated at all post-vaccination time points. There was no correlation between GrzB response and hemagglutination inhibition (HAI) titers, indicating no relationship between the cytolytic activity and humoral antibody levels in this cohort. Additionally, a significant negative correlation between GrzB response and age was observed. These results reveal a reduction in influenza-specific GrzB response as one ages. In conclusion, we have developed and optimized an influenza-specific ELISPOT assay for use with frozen cells to quantify the CTL-specific serine protease GrzB, as a measure of cellular immunity after influenza vaccination. © 2013.

  14. Home-made temperature monitoring system from four-channel K-type thermocouples via internet of thing technology platform

    NASA Astrophysics Data System (ADS)

    Detmod, Thitaporn; Özmen, Yiǧiter; Songkaitiwong, Kittiphot; Saenyot, Khanuengchat; Locharoenrat, Kitsakorn; Lekchaum, Sarai

    2018-06-01

    This paper is aimed to design and construct the home-made temperature monitoring system from four-channel K-type thermocouples in order to improve the temperature measurement based on standard evaluation measurements guidance. The temperature monitoring system was capable to record the temperature on SD card and to display the realtime temperature on Internet of Thing Technology platform. The temperature monitoring system was tested in terms of the temperature measurement accuracy and delay response time. It was found that a standard deviation was acceptable as compared to the Instrument Society of America. The response time of the microcontroller to SD card was 2 sec faster than that of the microcontroller to Thingspeak.

  15. Real-Time Functional Magnetic Resonance Imaging Amygdala Neurofeedback Changes Positive Information Processing in Major Depressive Disorder.

    PubMed

    Young, Kymberly D; Misaki, Masaya; Harmer, Catherine J; Victor, Teresa; Zotev, Vadim; Phillips, Raquel; Siegle, Greg J; Drevets, Wayne C; Bodurka, Jerzy

    2017-10-15

    In participants with major depressive disorder who are trained to upregulate their amygdalar hemodynamic responses during positive autobiographical memory recall with real-time functional magnetic resonance imaging neurofeedback (rtfMRI-nf) training, depressive symptoms diminish. This study tested whether amygdalar rtfMRI-nf also changes emotional processing of positive and negative stimuli in a variety of behavioral and imaging tasks. Patients with major depressive disorder completed two rtfMRI-nf sessions (18 received amygdalar rtfMRI-nf, 16 received control parietal rtfMRI-nf). One week before and following rtfMRI-nf training, participants performed tasks measuring responses to emotionally valenced stimuli including a backward-masking task, which measures the amygdalar hemodynamic response to emotional faces presented for traditionally subliminal duration and followed by a mask, and the Emotional Test Battery in which reaction times and performance accuracy are measured during tasks involving emotional faces and words. During the backward-masking task, amygdalar responses increased while viewing masked happy faces but decreased to masked sad faces in the experimental versus control group following rtfMRI-nf. During the Emotional Test Battery, reaction times decreased to identification of positive faces and during self-identification with positive words and vigilance scores increased to positive faces and decreased to negative faces during the faces dot-probe task in the experimental versus control group following rtfMRI-nf. rtfMRI-nf training to increase the amygdalar hemodynamic response to positive memories was associated with changes in amygdalar responses to happy and sad faces and improved processing of positive stimuli during performance of the Emotional Test Battery. These results may suggest that amygdalar rtfMRI-nf training alters responses to emotional stimuli in a manner similar to antidepressant pharmacotherapy. Copyright © 2017 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  16. Acidosis slows the response of oxidative phosphorylation to metabolic demand in isolated rabbit heart.

    PubMed

    Hak, J B; van Beek, J H; Westerhof, N

    1993-05-01

    The purpose of this study was to investigate the effect of acidosis on the mean response time of mitochondrial oxygen consumption to steps in heart rate and in left ventricular balloon volume. The mean response time may be viewed as the average delay between a change in adenosine triphosphate (ATP) hydrolysis and oxygen consumption. The mean response time is calculated by subtracting the transport time, required for diffusion of oxygen and for convective transport through the coronary vessels, from the response time measured in the coronary venous effluent. Eight isolated rabbit hearts were perfused according to Langendorff using Tyrode solution at 28 degrees C. Arterial perfusate pH was lowered from 7.30 +/- 0.03 (mean +/- SD) to 6.59 +/- 0.02 by increasing the CO2 tension. At pH 7.3 the mean response time was 12.6 +/- 1.6 s, independent of the time after isolation of the heart. During acidosis, applied 40-75 min after isolation of the heart, the mean response time was 21.4 +/- 0.7 s and increased to 32.6 +/- 4.3 s during acidosis, 85-120 min after isolation. Thus the retardation of the metabolic response by acidosis might depend on the condition of the heart. A decrease of mitochondrial ATP synthetic capacity during acidosis may contribute to the retardation of the metabolic response. Since determination of the mean response time at 37 degrees C is not yet feasible, the experiments were done at 28 degrees C. Extrapolation of our findings to 37 degrees C appears premature.

  17. Acquisition and Analysis of Dynamic Responses of a Historic Pedestrian Bridge using Video Image Processing

    NASA Astrophysics Data System (ADS)

    O'Byrne, Michael; Ghosh, Bidisha; Schoefs, Franck; O'Donnell, Deirdre; Wright, Robert; Pakrashi, Vikram

    2015-07-01

    Video based tracking is capable of analysing bridge vibrations that are characterised by large amplitudes and low frequencies. This paper presents the use of video images and associated image processing techniques to obtain the dynamic response of a pedestrian suspension bridge in Cork, Ireland. This historic structure is one of the four suspension bridges in Ireland and is notable for its dynamic nature. A video camera is mounted on the river-bank and the dynamic responses of the bridge have been measured from the video images. The dynamic response is assessed without the need of a reflector on the bridge and in the presence of various forms of luminous complexities in the video image scenes. Vertical deformations of the bridge were measured in this regard. The video image tracking for the measurement of dynamic responses of the bridge were based on correlating patches in time-lagged scenes in video images and utilisinga zero mean normalisedcross correlation (ZNCC) metric. The bridge was excited by designed pedestrian movement and by individual cyclists traversing the bridge. The time series data of dynamic displacement responses of the bridge were analysedto obtain the frequency domain response. Frequencies obtained from video analysis were checked against accelerometer data from the bridge obtained while carrying out the same set of experiments used for video image based recognition.

  18. Acquisition and Analysis of Dynamic Responses of a Historic Pedestrian Bridge using Video Image Processing

    NASA Astrophysics Data System (ADS)

    O'Byrne, Michael; Ghosh, Bidisha; Schoefs, Franck; O'Donnell, Deirdre; Wright, Robert; Pakrashi, Vikram

    2015-07-01

    Video based tracking is capable of analysing bridge vibrations that are characterised by large amplitudes and low frequencies. This paper presents the use of video images and associated image processing techniques to obtain the dynamic response of a pedestrian suspension bridge in Cork, Ireland. This historic structure is one of the four suspension bridges in Ireland and is notable for its dynamic nature. A video camera is mounted on the river-bank and the dynamic responses of the bridge have been measured from the video images. The dynamic response is assessed without the need of a reflector on the bridge and in the presence of various forms of luminous complexities in the video image scenes. Vertical deformations of the bridge were measured in this regard. The video image tracking for the measurement of dynamic responses of the bridge were based on correlating patches in time-lagged scenes in video images and utilisinga zero mean normalised cross correlation (ZNCC) metric. The bridge was excited by designed pedestrian movement and by individual cyclists traversing the bridge. The time series data of dynamic displacement responses of the bridge were analysedto obtain the frequency domain response. Frequencies obtained from video analysis were checked against accelerometer data from the bridge obtained while carrying out the same set of experiments used for video image based recognition.

  19. Time-of-flight radio location system

    DOEpatents

    McEwan, T.E.

    1996-04-23

    A bi-static radar configuration measures the direct time-of-flight of a transmitted RF pulse and is capable of measuring this time-of-flight with a jitter on the order of about one pico-second, or about 0.01 inch of free space distance for an electromagnetic pulse over a range of about one to ten feet. A transmitter transmits a sequence of electromagnetic pulses in response to a transmit timing signal, and a receiver samples the sequence of electromagnetic pulses with controlled timing in response to a receive timing signal, and generates a sample signal in response to the samples. A timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the sequence of electromagnetic pulses such that the time between transmission of pulses in the sequence and sampling by the receiver sweeps over a range of delays. The receive timing signal sweeps over the range of delays in a sweep cycle such that pulses in the sequence are sampled at the pulse repetition rate, and with different delays in the range of delays to produce a sample signal representing magnitude of a received pulse in equivalent time. Automatic gain control circuitry in the receiver controls the magnitude of the equivalent time sample signal. A signal processor analyzes the sample signal to indicate the time-of-flight of the electromagnetic pulses in the sequence. 7 figs.

  20. Time-of-flight radio location system

    DOEpatents

    McEwan, Thomas E.

    1996-01-01

    A bi-static radar configuration measures the direct time-of-flight of a transmitted RF pulse and is capable of measuring this time-of-flight with a jitter on the order of about one pico-second, or about 0.01 inch of free space distance for an electromagnetic pulse over a range of about one to ten feet. A transmitter transmits a sequence of electromagnetic pulses in response to a transmit timing signal, and a receiver samples the sequence of electromagnetic pulses with controlled timing in response to a receive timing signal, and generates a sample signal in response to the samples. A timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the sequence of electromagnetic pulses such that the time between transmission of pulses in the sequence and sampling by the receiver sweeps over a range of delays. The receive timing signal sweeps over the range of delays in a sweep cycle such that pulses in the sequence are sampled at the pulse repetition rate, and with different delays in the range of delays to produce a sample signal representing magnitude of a received pulse in equivalent time. Automatic gain control circuitry in the receiver controls the magnitude of the equivalent time sample signal. A signal processor analyzes the sample signal to indicate the time-of-flight of the electromagnetic pulses in the sequence.

  1. Determination of the water vapor continuum absorption by THz-TDS and Molecular Response Theory.

    PubMed

    Yang, Yihong; Mandehgar, Mahboubeh; Grischkowsky, D

    2014-02-24

    Determination of the water vapor continuum absorption from 0.35 to 1 THz is reported. The THz pulses propagate though a 137 m long humidity-controlled chamber and are measured by THz time-domain spectroscopy (THz-TDS). The average relative humidity along the entire THz path is precisely obtained by measuring the difference between transit times of the sample and reference THz pulses to an accuracy of 0.1 ps. Using the measured total absorption and the calculated resonance line absorption with the Molecular Response Theory lineshape, based on physical principles and measurements, an accurate continuum absorption is obtained within four THz absorption windows, that agrees well with the empirical theory. The absorption is significantly smaller than that obtained using the van Vleck-Weisskopf lineshape with a 750 GHz cut-off.

  2. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D.

    PubMed

    Chen, J; Ding, W X; Brower, D L; Finkenthal, D; Muscatello, C; Taussig, D; Boivin, R

    2016-11-01

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbations have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.

  3. Direct Measurement of the Photoelectric Response Time of Bacteriorhodopsin via Electro-Optic Sampling

    PubMed Central

    Xu, J.; Stickrath, A. B.; Bhattacharya, P.; Nees, J.; Váró, G.; Hillebrecht, J. R.; Ren, L.; Birge, R. R.

    2003-01-01

    The photovoltaic signal associated with the primary photochemical event in an oriented bacteriorhodopsin film is measured by directly probing the electric field in the bacteriorhodopsin film using an ultrafast electro-optic sampling technique. The inherent response time is limited only by the laser pulse width of 500 fs, and permits a measurement of the photovoltage with a bandwidth of better than 350 GHz. All previous published studies have been carried out with bandwidths of 50 GHz or lower. We observe a charge buildup with an exponential formation time of 1.68 ± 0.05 ps and an initial decay time of 31.7 ps. Deconvolution with a 500-fs Gaussian excitation pulse reduces the exponential formation time to 1.61 ± 0.04 ps. The photovoltaic signal continues to rise for 4.5 ps after excitation, and the voltage profile corresponds well with the population dynamics of the K state. The origin of the fast photovoltage is assigned to the partial isomerization of the chromophore and the coupled motion of the Arg-82 residue during the primary event. PMID:12885657

  4. Psychometric comparisons of the timed up and go, one-leg stand, functional reach, and Tinetti balance measures in community-dwelling older people.

    PubMed

    Lin, Mau-Roung; Hwang, Hei-Fen; Hu, Ming-Hsia; Wu, Hong-Dar Isaac; Wang, Yi-Wei; Huang, Fu-Chao

    2004-08-01

    To compare the practicality, reliability, validity, and responsiveness of the timed up and go (TUG), one-leg stand (OLS), functional reach (FR), and Tinetti balance (TB) performance measures in people aged 65 and older. A prospective study. Shin-Sher Township of Taichung County, west-central Taiwan. Twelve hundred community-dwelling older people. During an initial assessment at their residences, participants were interviewed for demographics, cognition, fall history, use of a walking aid, and activities of daily living (ADLs), in addition to completing the four balance tests. Falls were ascertained by telephone every 3 months for a 1-year follow-up; the four balance measures and ADLs were also reassessed at the end of the follow-up year. Of the four balance measures, the OLS had the lowest participation rate, and participation of people who were cognitively impaired had fallen in the previous year, used a walking aid, or suffered from an ADL disability was lower than for their counterparts. The time to complete the tests ranged from 58 seconds for OLS, to 160 seconds for the TB. All four balance measures exhibited excellent test-retest reliability and discriminant validity but poor responsiveness to fall status. The TB showed better discriminant, convergent, and predictive validities and responsiveness to ADL changes than the other three tests. According to psychometric properties, the most suitable performance measure for evaluating balance in community-dwelling older people was the TB, followed by the TUG.

  5. Go or No-Go? Developmental Improvements in the Efficiency of Response Inhibition in Mid-Childhood

    ERIC Educational Resources Information Center

    Cragg, Lucy; Nation, Kate

    2008-01-01

    This experiment used a modified go/no-go paradigm to investigate the processes by which response inhibition becomes more efficient during mid-childhood. The novel task, which measured trials on which a response was initiated but not completed, was sensitive to developmental changes in response inhibition. The effect of inducing time pressure by…

  6. Fission-neutrons source with fast neutron-emission timing

    NASA Astrophysics Data System (ADS)

    Rusev, G.; Baramsai, B.; Bond, E. M.; Jandel, M.

    2016-05-01

    A neutron source with fast timing has been built to help with detector-response measurements. The source is based on the neutron emission from the spontaneous fission of 252Cf. The time is provided by registering the fission fragments in a layer of a thin scintillation film with a signal rise time of 1 ns. The scintillation light output is measured by two silicon photomultipliers with rise time of 0.5 ns. Overall time resolution of the source is 0.3 ns. Design of the source and test measurements using it are described. An example application of the source for determining the neutron/gamma pulse-shape discrimination by a stilbene crystal is given.

  7. Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy.

    PubMed

    Bruza, Petr; Gollub, Sarah L; Andreozzi, Jacqueline M; Tendler, Irwin I; Williams, Benjamin B; Jarvis, Lesley A; Gladstone, David J; Pogue, Brian W

    2018-05-02

    The purpose of this study was to measure surface dose by remote time-gated imaging of plastic scintillators. A novel technique for time-gated, intensified camera imaging of scintillator emission was demonstrated, and key parameters influencing the signal were analyzed, including distance, angle and thickness. A set of scintillator samples was calibrated by using thermo-luminescence detector response as reference. Examples of use in total skin electron therapy are described. The data showed excellent room light rejection (signal-to-noise ratio of scintillation SNR  ≈  470), ideal scintillation dose response linearity, and 2% dose rate error. Individual sample scintillation response varied by 7% due to sample preparation. Inverse square distance dependence correction and lens throughput error (8% per meter) correction were needed. At scintillator-to-source angle and observation angle  <50°, the radiant energy fluence error was smaller than 1%. The achieved standard error of the scintillator cumulative dose measurement compared to the TLD dose was 5%. The results from this proof-of-concept study documented the first use of small scintillator targets for remote surface dosimetry in ambient room lighting. The measured dose accuracy renders our method to be comparable to thermo-luminescent detector dosimetry, with the ultimate realization of accuracy likely to be better than shown here. Once optimized, this approach to remote dosimetry may substantially reduce the time and effort required for surface dosimetry.

  8. Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy

    NASA Astrophysics Data System (ADS)

    Bruza, Petr; Gollub, Sarah L.; Andreozzi, Jacqueline M.; Tendler, Irwin I.; Williams, Benjamin B.; Jarvis, Lesley A.; Gladstone, David J.; Pogue, Brian W.

    2018-05-01

    The purpose of this study was to measure surface dose by remote time-gated imaging of plastic scintillators. A novel technique for time-gated, intensified camera imaging of scintillator emission was demonstrated, and key parameters influencing the signal were analyzed, including distance, angle and thickness. A set of scintillator samples was calibrated by using thermo-luminescence detector response as reference. Examples of use in total skin electron therapy are described. The data showed excellent room light rejection (signal-to-noise ratio of scintillation SNR  ≈  470), ideal scintillation dose response linearity, and 2% dose rate error. Individual sample scintillation response varied by 7% due to sample preparation. Inverse square distance dependence correction and lens throughput error (8% per meter) correction were needed. At scintillator-to-source angle and observation angle  <50°, the radiant energy fluence error was smaller than 1%. The achieved standard error of the scintillator cumulative dose measurement compared to the TLD dose was 5%. The results from this proof-of-concept study documented the first use of small scintillator targets for remote surface dosimetry in ambient room lighting. The measured dose accuracy renders our method to be comparable to thermo-luminescent detector dosimetry, with the ultimate realization of accuracy likely to be better than shown here. Once optimized, this approach to remote dosimetry may substantially reduce the time and effort required for surface dosimetry.

  9. Measurement of luminescence decays: High performance at low cost

    NASA Astrophysics Data System (ADS)

    Sulkes, Mark; Sulkes, Zoe

    2011-11-01

    The availability of inexpensive ultra bright LEDs spanning the visible and near-ultraviolet combined with the availability of inexpensive electronics equipment makes it possible to construct a high performance luminescence lifetime apparatus (˜5 ns instrumental response or better) at low cost. A central need for time domain measurement systems is the ability to obtain short (˜1 ns or less) excitation light pulses from the LEDs. It is possible to build the necessary LED driver using a simple avalanche transistor circuit. We describe first a circuit to test for small signal NPN transistors that can avalanche. We then describe a final optimized avalanche mode circuit that we developed on a prototyping board by measuring driven light pulse duration as a function of the circuit on the board and passive component values. We demonstrate that the combination of the LED pulser and a 1P28 photomultiplier tube used in decay waveform acquisition has a time response that allows for detection and lifetime determination of luminescence decays down to ˜5 ns. The time response and data quality afforded with the same components in time-correlated single photon counting are even better. For time-correlated single photon counting an even simpler NAND-gate based LED driver circuit is also applicable. We also demonstrate the possible utility of a simple frequency domain method for luminescence lifetime determinations.

  10. Reaction time in pilots during intervals of high sustained g.

    PubMed

    Truszczynski, Olaf; Lewkowicz, Rafal; Wojtkowiak, Mieczyslaw; Biernacki, Marcin P

    2014-11-01

    An important problem for pilots is visual disturbances occurring under +Gz acceleration. Assessment of the degree of intensification of these disturbances is generally accepted as the acceleration tolerance level (ATL) criterion determined in human centrifuges. The aim of this research was to evaluate the visual-motor responses of pilots during rapidly increasing acceleration contained in cyclic intervals of +6 Gz to the maximum ATL. The study involved 40 male pilots ages 32-41 yr. The task was a quick and faultless response to the light stimuli presented on a light bar during exposure to acceleration until reaching the ATL. Simple response time (SRT) measurements were performed using a visual-motor analysis system throughout the exposures which allowed assessment of a pilot's ATL. There were 29 pilots who tolerated the initial phase of interval acceleration and achieved +6 Gz, completing the test at ATL. Relative to the control measurements, the obtained results indicate a significant effect of the applied acceleration on response time. SRT during +6 Gz exposure was not significantly longer compared with the reaction time between each of the intervals. SRT and erroneous reactions indicated no statistically significant differences between the "lower" and "higher" ATL groups. SRT measurements over the +6-Gz exposure intervals did not vary between "lower" and "higher" ATL groups and, therefore, are not useful in predicting pilot performance. The gradual exposure to the maximum value of +6 Gz with exposure to the first three intervals on the +6-Gz plateau effectively differentiated pilots.

  11. Limitations of the ideal phase-Doppler system: Extension to spatially and temporally inhomogeneous particle flows with an application to diesel sprays

    NASA Astrophysics Data System (ADS)

    Marx, K. D.; Edwards, C. F.

    1992-12-01

    The effect of the single-particle constraint on the response of phase-Doppler instruments is determined for particle flows which are spatially nonuniform and time-dependent. Poisson statistics are applied to particle positions and arrival times within the phase-Doppler probe volume to determine the probability that a particle is measured successfully. It is shown that the single-particle constraint can be viewed as applying spatial and temporal filters to the particle flow. These filters have the same meaning as those that were defined previously for uniform, steady-state sprays, but in space- and time-dependent form. Criteria are developed for determining when a fully inhomogeneous analysis of a flow is required and when a quasi-steady analysis will suffice. A new bias due to particle arrival time displacement is identified and the conditions under which it must be considered are established. The present work provides the means to rigorously investigate the response of phase-Doppler measurement systems to transient sprays such as those which occur in diesel engines. To this end, the results are applied to a numerical simulation of a diesel spray. The calculated hypothetical response of the ideal instrument provides a quantitative demonstration of the regimes within which measurements can accurately be made in such sprays.

  12. The Impact of Non-attempted and Dually-Attempted Items on Person Abilities Using Item Response Theory

    PubMed Central

    Sideridis, Georgios D.; Tsaousis, Ioannis; Al Harbi, Khaleel

    2016-01-01

    The purpose of the present study was to relate response strategy with person ability estimates. Two behavioral strategies were examined: (a) the strategy to skip items in order to save time on timed tests, and, (b) the strategy to select two responses on an item, with the hope that one of them may be considered correct. Participants were 4,422 individuals who were administered a standardized achievement measure related to math, biology, chemistry, and physics. In the present evaluation, only the physics subscale was employed. Two analyses were conducted: (a) a person-based one to identify differences between groups and potential correlates of those differences, and, (b) a measure-based analysis in order to identify the parts of the measure that were responsible for potential group differentiation. For (a) person abilities the 2-PL model was employed and later the 3-PL and 4-PL models in order to estimate upper and lower asymptotes of person abilities. For (b) differential item functioning, differential test functioning, and differential distractor functioning were investigated. Results indicated that there were significant differences between groups with completers having the highest ability compared to both non-attempters and dual responders. There were no significant differences between no-attempters and dual responders. The present findings have implications for response strategy efficacy and measure evaluation, revision, and construction. PMID:27790174

  13. The Impact of Non-attempted and Dually-Attempted Items on Person Abilities Using Item Response Theory.

    PubMed

    Sideridis, Georgios D; Tsaousis, Ioannis; Al Harbi, Khaleel

    2016-01-01

    The purpose of the present study was to relate response strategy with person ability estimates. Two behavioral strategies were examined: (a) the strategy to skip items in order to save time on timed tests, and, (b) the strategy to select two responses on an item, with the hope that one of them may be considered correct. Participants were 4,422 individuals who were administered a standardized achievement measure related to math, biology, chemistry, and physics. In the present evaluation, only the physics subscale was employed. Two analyses were conducted: (a) a person-based one to identify differences between groups and potential correlates of those differences, and, (b) a measure-based analysis in order to identify the parts of the measure that were responsible for potential group differentiation. For (a) person abilities the 2-PL model was employed and later the 3-PL and 4-PL models in order to estimate upper and lower asymptotes of person abilities. For (b) differential item functioning, differential test functioning, and differential distractor functioning were investigated. Results indicated that there were significant differences between groups with completers having the highest ability compared to both non-attempters and dual responders. There were no significant differences between no-attempters and dual responders. The present findings have implications for response strategy efficacy and measure evaluation, revision, and construction.

  14. Comparison of measurement data at the impeller exit of a centrifugal compressor measured with both pneumatic and fast-response probes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roduner, C.; Koeppel, P.; Kupferschmied, P.

    1999-07-01

    The main goal of these investigations was the refined measurement of unsteady high speed flow in a centrifugal compressor using the advanced FRAP{reg_sign} fast-response aerodynamic probe system. The present contribution focuses on the impeller exit region and shows critical comparisons between fast-response (time-resolving) and conventional pneumatic probe measurement results. Three probes of identical geometry (one fast and two pneumatic) were used to perform wall-to-wall traverses close to impeller exit. The data shown refer to a single running condition near the best point of the stage. The mass flow obtained from different probe measurements and from the standard orifice measurement weremore » compared. Stage work obtained from temperature rise measured with a FRAP{reg_sign} probe and from impeller outlet velocity vectors fields by using Euler`s turbine equation are presented. The comparison in terms of velocity magnitude and angle distribution is quite satisfactory, indicating the superior DC measurement capabilities of the fast-response probe system.« less

  15. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E. (Inventor); Taylor, Bryant D. (Inventor); Shams, Qamar A. (Inventor); Fox, Robert L. (Inventor); Fox, Christopher L. (Inventor); Fox, Melanie L. (Inventor); Bryant, Robert G. (Inventor)

    2006-01-01

    Magnetic field response sensors designed as passive inductor-capacitor circuits produce magnetic field responses whose harmonic frequencies correspond to states of physical properties for which the sensors measure. Power to the sensing element is acquired using Faraday induction. A radio frequency antenna produces the time varying magnetic field used for powering the sensor, as well as receiving the magnetic field response of the sensor. An interrogation architecture for discerning changes in sensor s response kequency, resistance and amplitude is integral to the method thus enabling a variety of measurements. Multiple sensors can be interrogated using this method, thus eliminating the need to have a data acquisition channel dedicated to each sensor. The method does not require the sensors to be in proximity to any form of acquisition hardware. A vast array of sensors can be used as interchangeable parts in an overall sensing system.

  16. The Relationship of Item-Level Response Times with Test-Taker and Item Variables in an Operational CAT Environment. LSAC Research Report Series.

    ERIC Educational Resources Information Center

    Swygert, Kimberly A.

    In this study, data from an operational computerized adaptive test (CAT) were examined in order to gather information concerning item response times in a CAT environment. The CAT under study included multiple-choice items measuring verbal, quantitative, and analytical reasoning. The analyses included the fitting of regression models describing the…

  17. On the Reliability and Validity of a Numerical Reasoning Speed Dimension Derived from Response Times Collected in Computerized Testing

    ERIC Educational Resources Information Center

    Davison, Mark L.; Semmes, Robert; Huang, Lan; Close, Catherine N.

    2012-01-01

    Data from 181 college students were used to assess whether math reasoning item response times in computerized testing can provide valid and reliable measures of a speed dimension. The alternate forms reliability of the speed dimension was .85. A two-dimensional structural equation model suggests that the speed dimension is related to the accuracy…

  18. 75 FR 35813 - Notice of Public Information Collection(s) Being Submitted for Review and Approval to the Office...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-23

    ... requires station licensees to measure the carrier frequency, output power, and modulation of each..., 409,048 responses. Estimated Time per Response: .033 hours. Frequency of Response: Recordkeeping... installed and when any changes are made which would likely affect the modulation characteristics. Such...

  19. 75 FR 15430 - Notice of Public Information Collection Being Reviewed by the Federal Communications Commission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-29

    ... respondents; 409,048 responses. Estimated Time Per Response: .033 hours Frequency of Response: Recordkeeping... previous estimates. Section 90.215 requires station licensees to measure the carrier frequency, output power, and modulation of each transmitter authorized to operate with power in excess of two watts when...

  20. High-resolution continuous-flow analysis setup for water isotopic measurement from ice cores using laser spectroscopy

    NASA Astrophysics Data System (ADS)

    Emanuelsson, B. D.; Baisden, W. T.; Bertler, N. A. N.; Keller, E. D.; Gkinis, V.

    2015-07-01

    Here we present an experimental setup for water stable isotope (δ18O and δD) continuous-flow measurements and provide metrics defining the performance of the setup during a major ice core measurement campaign (Roosevelt Island Climate Evolution; RICE). We also use the metrics to compare alternate systems. Our setup is the first continuous-flow laser spectroscopy system that is using off-axis integrated cavity output spectroscopy (OA-ICOS; analyzer manufactured by Los Gatos Research, LGR) in combination with an evaporation unit to continuously analyze water samples from an ice core. A Water Vapor Isotope Standard Source (WVISS) calibration unit, manufactured by LGR, was modified to (1) enable measurements on several water standards, (2) increase the temporal resolution by reducing the response time and (3) reduce the influence from memory effects. While this setup was designed for the continuous-flow analysis (CFA) of ice cores, it can also continuously analyze other liquid or vapor sources. The custom setups provide a shorter response time (~ 54 and 18 s for 2013 and 2014 setup, respectively) compared to the original WVISS unit (~ 62 s), which is an improvement in measurement resolution. Another improvement compared to the original WVISS is that the custom setups have a reduced memory effect. Stability tests comparing the custom and WVISS setups were performed and Allan deviations (σAllan) were calculated to determine precision at different averaging times. For the custom 2013 setup the precision after integration times of 103 s is 0.060 and 0.070 ‰ for δ18O and δD, respectively. The corresponding σAllan values for the custom 2014 setup are 0.030, 0.060 and 0.043 ‰ for δ18O, δD and δ17O, respectively. For the WVISS setup the precision is 0.035, 0.070 and 0.042 ‰ after 103 s for δ18O, δD and δ17O, respectively. Both the custom setups and WVISS setup are influenced by instrumental drift with δ18O being more drift sensitive than δD. The σAllan values for δ18O are 0.30 and 0.18 ‰ for the custom 2013 and WVISS setup, respectively, after averaging times of 104 s (2.78 h). Using response time tests and stability tests, we show that the custom setups are more responsive (shorter response time), whereas the University of Copenhagen (UC) setup is more stable. More broadly, comparisons of different setups address the challenge of integrating vaporizer/spectrometer isotope measurement systems into a CFA campaign with many other analytical instruments.

  1. Test-retest reliability of sudden ankle inversion measurements in subjects with healthy ankle joints.

    PubMed

    Eechaute, Christophe; Vaes, Peter; Duquet, William; Van Gheluwe, Bart

    2007-01-01

    Sudden ankle inversion tests have been used to investigate whether the onset of peroneal muscle activity is delayed in patients with chronically unstable ankle joints. Before interpreting test results of latency times in patients with chronic ankle instability and healthy subjects, the reliability of these measures must be first demonstrated. To investigate the test-retest reliability of variables measured during a sudden ankle inversion movement in standing subjects with healthy ankle joints. Validation study. Research laboratory. 15 subjects with healthy ankle joints (30 ankles). Subjects stood on an ankle inversion platform with both feet tightly fixed to independently moveable trapdoors. An unexpected sudden ankle inversion of 50 degrees was imposed. We measured latency and motor response times and electromechanical delay of the peroneus longus muscle, along with the time and angular position of the first and second decelerating moments, the mean and maximum inversion speed, and the total inversion time. Correlation coefficients and standard error of measurements were calculated. Intraclass correlation coefficients ranged from 0.17 for the electromechanical delay of the peroneus longus muscle (standard error of measurement = 2.7 milliseconds) to 0.89 for the maximum inversion speed (standard error of measurement = 34.8 milliseconds). The reliability of the latency and motor response times of the peroneus longus muscle, the time of the first and second decelerating moments, and the mean and maximum inversion speed was acceptable in subjects with healthy ankle joints and supports the investigation of the reliability of these measures in subjects with chronic ankle instability. The lower reliability of the electromechanical delay of the peroneus longus muscle and the angular positions of both decelerating moments calls the use of these variables into question.

  2. C-terminal threonines and serines play distinct roles in the desensitization of rhodopsin, a G protein-coupled receptor

    PubMed Central

    Azevedo, Anthony W; Doan, Thuy; Moaven, Hormoz; Sokal, Iza; Baameur, Faiza; Vishnivetskiy, Sergey A; Homan, Kristoff T; Tesmer, John JG; Gurevich, Vsevolod V; Chen, Jeannie; Rieke, Fred

    2015-01-01

    Rod photoreceptors generate measurable responses to single-photon activation of individual molecules of the G protein-coupled receptor (GPCR), rhodopsin. Timely rhodopsin desensitization depends on phosphorylation and arrestin binding, which quenches G protein activation. Rhodopsin phosphorylation has been measured biochemically at C-terminal serine residues, suggesting that these residues are critical for producing fast, low-noise responses. The role of native threonine residues is unclear. We compared single-photon responses from rhodopsin lacking native serine or threonine phosphorylation sites. Contrary to expectation, serine-only rhodopsin generated prolonged step-like single-photon responses that terminated abruptly and randomly, whereas threonine-only rhodopsin generated responses that were only modestly slower than normal. We show that the step-like responses of serine-only rhodopsin reflect slow and stochastic arrestin binding. Thus, threonine sites play a privileged role in promoting timely arrestin binding and rhodopsin desensitization. Similar coordination of phosphorylation and arrestin binding may more generally permit tight control of the duration of GPCR activity. DOI: http://dx.doi.org/10.7554/eLife.05981.001 PMID:25910054

  3. Valve movement response of the freshwater clam Corbicula fluminea following exposure to waterborne arsenic.

    PubMed

    Liao, Chung-Min; Jau, Sheng-Feng; Lin, Chieh-Ming; Jou, Li-John; Liu, Chen-Wuing; Liao, Vivian Hsiu-Chuan; Chang, Fi-John

    2009-07-01

    We developed an inductance-based valvometry technique as a detection system to measure the valve daily activity in freshwater clam Corbicula fluminea in response to waterborne arsenic. Our findings reveal that C. fluminea experiences a valve opening in the absence of arsenic predominantly in the morning hours (03:00-08:00) with a mean daily opening/closing period of 21.32 (95% CI: 20.58-22.05) h. Amplification of daily activity occurred in the presence of arsenic. Behavioral toxicity assays revealed arsenic detection thresholds of 0.60 (95% CI: 0.53-0.66) mg l(-1) and 0.35 (95% CI: 0.30-0.40) mg l(-1) for response times of 60 and 300 min, respectively. The proposed valve daily activity model was linked with response time-specific Hill dose-response functions to predict valve opening/closing behavior in response to arsenic. The predictive capabilities were verified satisfactory with the measurements. Our results implicate a biomonitoring system by valve daily activity in C. fluminea to identify safe water uses in areas with elevated arsenic.

  4. High-resolution Measurements of Gas-Phase Hydrogen Chloride (HCl) in the Atmosphere by Cavity Ring Down Spectroscopy

    NASA Astrophysics Data System (ADS)

    Hoffnagle, John; Chen, Hongbing; Lee, Jim; Rella, Chris; Kim-Hak, David; Winkler, Renato; Markovic, Milos; Veres, Patrick

    2017-04-01

    Halogen radical species, such as chlorine and bromine atoms and their oxides, can greatly affect the chemical composition of the troposphere. Hydrogen chloride is the dominant (gas-phase) contributor to the tropospheric chlorine inventory. Real time in situ observations of HCl can provide an important window into the complex photochemical reaction pathways for chlorine in the atmosphere, including heterogeneous reactions on aerosol surfaces. In this work, we report a novel, commercially-available HCl gas-phase analyzer (G2108, Picarro Inc. Santa Clara, CA, USA) based upon Cavity Ring Down Spectroscopy (CRDS) in the near-infrared, and discuss its performance. With a measurement interval of approximately 2 seconds, a precision of better than 40 parts-per-trillion (1 sigma, 30 seconds), and a response time of approximately 1-2 minutes (10 - 90% rise time or 90 - 10% fall time), this analyzer is well-suited for measurements of atmospherically-relevant concentrations of HCl, in both laboratory and field. CRDS provides very stable measurements and low drift, requiring infrequent calibration of the instrument, and can therefore be operated remotely for extended periods of time. In this work we also present results from a laboratory intercomparison of the Picarro G2108 analyzer and an iodide ion time-of-flight Chemical Ionization Mass Spectrometer (CIMS), and the results of the analyzer time response tests.

  5. Measurement of respiratory rate and timing using a nasal thermocouple.

    PubMed

    Marks, M K; South, M; Carter, B G

    1995-05-01

    The aims of this study were to assess aspects of the response of a small thermocouple to temperature change, and to evaluate whether such a thermocouple could be used intermittently to measure respiratory rate and timing by detecting the changes in nasal temperature occurring with breathing. The study had three parts. First, three similar, fast-responding thermocouples were immersed repeatedly in warm water. Second, the influence of atmospheric temperature on the signal of a thermocouple placed at different sites within the nasal orifice was studied. The signals produced were continuously displayed and analyzed using a laptop computer to allow evaluation of the thermocouples' response characteristics. Third, simultaneous respiratory recordings were acquired using a nasal thermocouple and a nasal pneumotachograph in 12 teenaged subjects. The respiratory rate and the periods of time taken for inspiration (Ti) and expiration (Te) were calculated and compared. The thermocouples' responses to the temperature changes associated with breathing and immersion into water were rapid and consistent. The rate of the signals' decay, following the peak signal marking expiration, was influenced by the atmospheric temperature. The time constants of the thermocouples were similar (mean time constant = 0.41 sec, standard deviation (SD) = 0.07). Optimal respiratory recordings were obtained, with least discomfort, when the thermocouple was positioned at 0 to 4 mm within the nasal orifice. In comparing the respiratory recordings acquired simultaneously with a thermocouple and pneumotachograph, the respiratory rates were identical, and the Ti and Te values were similar (mean difference 0.04 sec (95% CI: -0.11 to 0.21 sec) and -0.04 sec (95% CI: -0.20 to 0.12 sec), respectively). Intermittent measurements of respiratory rate and timing using a nasal thermocouple accurately reflected measurements obtained from nasal airflow using a pneumotachograph.

  6. DEVELOPMENT AND PEER REVIEW OF TIME-TO-EFFECT MODELS FOR THE ANALYSIS OF NEUROTOXICITY AND OTHER TIME DEPENDENT DATA

    EPA Science Inventory

    Neurobehavioral studies pose unique challenges for dose-response modeling, including small sample size and relatively large intra-subject variation, repeated measurements over time, multiple endpoints with both continuous and ordinal scales, and time dependence of risk characteri...

  7. Poster - 16: Time-resolved diode dosimetry for in vivo proton therapy range verification: calibration through numerical modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toltz, Allison; Hoesl, Michaela; Schuemann, Jan

    Purpose: A method to refine the implementation of an in vivo, adaptive proton therapy range verification methodology was investigated. Simulation experiments and in-phantom measurements were compared to validate the calibration procedure of a time-resolved diode dosimetry technique. Methods: A silicon diode array system has been developed and experimentally tested in phantom for passively scattered proton beam range verification by correlating properties of the detector signal to the water equivalent path length (WEPL). The implementation of this system requires a set of calibration measurements to establish a beam-specific diode response to WEPL fit for the selected ‘scout’ beam in a solidmore » water phantom. This process is both tedious, as it necessitates a separate set of measurements for every ‘scout’ beam that may be appropriate to the clinical case, as well as inconvenient due to limited access to the clinical beamline. The diode response to WEPL relationship for a given ‘scout’ beam may be determined within a simulation environment, facilitating the applicability of this dosimetry technique. Measurements for three ‘scout’ beams were compared against simulated detector response with Monte Carlo methods using the Tool for Particle Simulation (TOPAS). Results: Detector response in water equivalent plastic was successfully validated against simulation for spread out Bragg peaks of range 10 cm, 15 cm, and 21 cm (168 MeV, 177 MeV, and 210 MeV) with adjusted R{sup 2} of 0.998. Conclusion: Feasibility has been shown for performing calibration of detector response for a given ‘scout’ beam through simulation for the time resolved diode dosimetry technique.« less

  8. The "Motor" in Implicit Motor Sequence Learning: A Foot-stepping Serial Reaction Time Task.

    PubMed

    Du, Yue; Clark, Jane E

    2018-05-03

    This protocol describes a modified serial reaction time (SRT) task used to study implicit motor sequence learning. Unlike the classic SRT task that involves finger-pressing movements while sitting, the modified SRT task requires participants to step with both feet while maintaining a standing posture. This stepping task necessitates whole body actions that impose postural challenges. The foot-stepping task complements the classic SRT task in several ways. The foot-stepping SRT task is a better proxy for the daily activities that require ongoing postural control, and thus may help us better understand sequence learning in real-life situations. In addition, response time serves as an indicator of sequence learning in the classic SRT task, but it is unclear whether response time, reaction time (RT) representing mental process, or movement time (MT) reflecting the movement itself, is a key player in motor sequence learning. The foot-stepping SRT task allows researchers to disentangle response time into RT and MT, which may clarify how motor planning and movement execution are involved in sequence learning. Lastly, postural control and cognition are interactively related, but little is known about how postural control interacts with learning motor sequences. With a motion capture system, the movement of the whole body (e.g., the center of mass (COM)) can be recorded. Such measures allow us to reveal the dynamic processes underlying discrete responses measured by RT and MT, and may aid in elucidating the relationship between postural control and the explicit and implicit processes involved in sequence learning. Details of the experimental set-up, procedure, and data processing are described. The representative data are adopted from one of our previous studies. Results are related to response time, RT, and MT, as well as the relationship between the anticipatory postural response and the explicit processes involved in implicit motor sequence learning.

  9. Mathematical modeling improves EC50 estimations from classical dose-response curves.

    PubMed

    Nyman, Elin; Lindgren, Isa; Lövfors, William; Lundengård, Karin; Cervin, Ida; Sjöström, Theresia Arbring; Altimiras, Jordi; Cedersund, Gunnar

    2015-03-01

    The β-adrenergic response is impaired in failing hearts. When studying β-adrenergic function in vitro, the half-maximal effective concentration (EC50 ) is an important measure of ligand response. We previously measured the in vitro contraction force response of chicken heart tissue to increasing concentrations of adrenaline, and observed a decreasing response at high concentrations. The classical interpretation of such data is to assume a maximal response before the decrease, and to fit a sigmoid curve to the remaining data to determine EC50 . Instead, we have applied a mathematical modeling approach to interpret the full dose-response curve in a new way. The developed model predicts a non-steady-state caused by a short resting time between increased concentrations of agonist, which affect the dose-response characterization. Therefore, an improved estimate of EC50 may be calculated using steady-state simulations of the model. The model-based estimation of EC50 is further refined using additional time-resolved data to decrease the uncertainty of the prediction. The resulting model-based EC50 (180-525 nm) is higher than the classically interpreted EC50 (46-191 nm). Mathematical modeling thus makes it possible to re-interpret previously obtained datasets, and to make accurate estimates of EC50 even when steady-state measurements are not experimentally feasible. The mathematical models described here have been submitted to the JWS Online Cellular Systems Modelling Database, and may be accessed at http://jjj.bio.vu.nl/database/nyman. © 2015 FEBS.

  10. Clinical responsiveness of self-report functional assessment measures for children with juvenile idiopathic arthritis undergoing intraarticular corticosteroid injections.

    PubMed

    Brown, G Ted; Wright, F Virginia; Lang, Bianca A; Birdi, Nina; Oen, Kim; Stephens, Derek; McComas, Joan; Feldman, Brian M

    2005-12-15

    The Childhood Health Assessment Questionnaire (CHAQ), Juvenile Arthritis Functional Assessment Report (JAFAR), and Juvenile Arthritis Functional Status Index (JASI) are widely used functional measures for juvenile idiopathic arthritis (JIA) that differ in content, format, and completion time. We compared the responsiveness and child-parent agreement of the JAFAR, CHAQ, and JASI in a prospective, multicenter study. Children and adolescents from 5 rheumatology centers were enrolled. Subjects were about to undergo therapy (intraarticular corticosteroid injections [IAS] and methotrexate or hip surgery (MTX/hip]) expected to produce a functional improvement. All subjects were studied before the intervention and at 6 weeks and 6 months posttreatment. At each study visit, the 3 measures were administered in randomized, balanced order to both parents and children. A total of 92 subjects (mean age 12.8 years) were enrolled in the study, 74 of which were in the IAS group. The responsiveness of all 3 measures was moderate to strong. The standardized response mean at 6 weeks for the IAS group on the JAFAR, CHAQ, and JASI was 0.41 (95% confidence interval [95% CI] 0.18, 0.64), 0.70 (95% CI 0.47, 0.93), and 0.36 (95% CI 0.13, 0.59), respectively. The CHAQ was somewhat more responsive to change at 6 weeks (IAS group: relative efficiency 0.34 [JAFAR], 0.27 [JASI]), but less responsive at 6 months (MTX/hip group: relative efficiency 5.1 [JAFAR], 3.9 [JASI]). All 3 questionnaires showed acceptable parent-child agreement, and overall, there were few differences between the 3 questionnaires. The functional outcome measures currently used for JIA are all adequately responsive for use in trials or in the clinic setting. The choice of which measure to use should therefore be based on the time available for completion, the intended clinical/research use, and the depth of content required.

  11. Novel method of measuring the mental workload of anaesthetists during clinical practice.

    PubMed

    Byrne, A J; Oliver, M; Bodger, O; Barnett, W A; Williams, D; Jones, H; Murphy, A

    2010-12-01

    Cognitive overload has been recognized as a significant cause of error in industries such as aviation and measuring mental workload has become a key method of improving safety. The aim of this study was to pilot the use of a new method of measuring mental workload in the operating theatre using a previously published methodology. The mental workload of the anaesthetists was assessed by measuring their response times to a wireless vibrotactile device and the NASA TLX subjective workload score during routine surgical procedures. Primary task workload was inferred from the phase of anaesthesia. Significantly increased response time was associated with the induction phase of anaesthesia compared with maintenance/emergence, non-consultant grade, and during more complex cases. Increased response was also associated with self-reported mental load, physical load, and frustration. These findings are consistent with periods of increased mental workload and with the findings of other studies using similar techniques. These findings confirm the importance of mental workload to the performance of anaesthetists and suggest that increased mental workload is likely to be a common problem in clinical practice. Although further studies are required, the method described may be useful for the measurement of the mental workload of anaesthetists.

  12. Effects of Extended Camera Baseline and Image Magnification on Target Detection Time and Target Recognition with a Stereoscopic TV System.

    DTIC Science & Technology

    1986-02-01

    rates. Target detection times were calculated by averaging response times for all trials within a treatment condition, excluding trials in which...responses in a treatment condition by the total number of valid trials within that condition. Each of these dependent measures was subjected to its own...or 1905 mm). Comparisons among the various treatment means for this effect revealed 13 4~ ~ q-. ~ ~ .-..... 2.309 A EXPERIMENT ONE. 2.29- 0 0 z 2.19

  13. Solar-Radiation Measuring Equipment and Glossary

    NASA Technical Reports Server (NTRS)

    Carter, E. A.; Patel, A. M.; Greenbaum, S. A.

    1982-01-01

    1976 listing of commercially available solar-radiation measuring equipment is presented in 50-page report. Sensor type, response time, cost data, and comments concerning specifications and intended usage are listed for 145 instruments from 38 manufactures.

  14. A Bivariate Generalized Linear Item Response Theory Modeling Framework to the Analysis of Responses and Response Times.

    PubMed

    Molenaar, Dylan; Tuerlinckx, Francis; van der Maas, Han L J

    2015-01-01

    A generalized linear modeling framework to the analysis of responses and response times is outlined. In this framework, referred to as bivariate generalized linear item response theory (B-GLIRT), separate generalized linear measurement models are specified for the responses and the response times that are subsequently linked by cross-relations. The cross-relations can take various forms. Here, we focus on cross-relations with a linear or interaction term for ability tests, and cross-relations with a curvilinear term for personality tests. In addition, we discuss how popular existing models from the psychometric literature are special cases in the B-GLIRT framework depending on restrictions in the cross-relation. This allows us to compare existing models conceptually and empirically. We discuss various extensions of the traditional models motivated by practical problems. We also illustrate the applicability of our approach using various real data examples, including data on personality and cognitive ability.

  15. Level of neurotic disorders among drivers causing traffic accidents.

    PubMed

    Durić, Predrag; Filipović, Danka

    2007-01-01

    Different aspects of driver personality may affect traffic safety. Extended driver reaction time causes deceleration of the reflexes, which is a major cause of traffic accidents. Cornell index was used in 30 drivers responsible for traffic accidents, with the aim to measure their level of neurotic disorder and compare them with results of controls (drivers not responsible for traffic accidents). Reaction time was maesured and compared among subjects with normal results of Cornell test and those with pathological findings. Drivers causing traffic accidents showed significantly higher Cornell index scores than drivers not responsible for traffic accidents. Drivers with pathological results of Cornell index showed a significantly longer reaction time.

  16. Observation of sub-100-fs optical response from spin-coated films of squarylium dye J aggregates

    NASA Astrophysics Data System (ADS)

    Furuki, Makoto; Tian, Minquan; Sato, Yasuhiro; Pu, Lyong Sun; Kawashima, Hitoshi; Tatsuura, Satoshi; Wada, Osamu

    2001-04-01

    For spin-coated films of squarylium dye J aggregates, ultrafast nonlinear optical responses were investigated by pump-probe measurements. By using a broadband mode-locked titanium:sapphire laser, we succeeded in observing the optical response with a time resolution of better than 60 fs. Time-resolved transmission data are shown for different excitation wavelengths, resonant to the excitonic absorption band and off-resonant. Relaxation times of the absorption saturation were evaluated to be 140 fs (fast component) and 950 fs (slow component) in the case of resonant excitation and 98 fs in the case of off-resonant excitation.

  17. Cognitive Reflection, Decision Biases, and Response Times

    PubMed Central

    Alós-Ferrer, Carlos; Garagnani, Michele; Hügelschäfer, Sabine

    2016-01-01

    We present novel evidence on response times and personality traits in standard questions from the decision-making literature where responses are relatively slow (medians around half a minute or above). To this end, we measured response times in a number of incentivized, framed items (decisions from description) including the Cognitive Reflection Test, two additional questions following the same logic, and a number of classic questions used to study decision biases in probability judgments (base-rate neglect, the conjunction fallacy, and the ratio bias). All questions create a conflict between an intuitive process and more deliberative thinking. For each item, we then created a non-conflict version by either making the intuitive impulse correct (resulting in an alignment question), shutting it down (creating a neutral question), or making it dominant (creating a heuristic question). For CRT questions, the differences in response times are as predicted by dual-process theories, with alignment and heuristic variants leading to faster responses and neutral questions to slower responses than the original, conflict questions. For decision biases (where responses are slower), evidence is mixed. To explore the possible influence of personality factors on both choices and response times, we used standard personality scales including the Rational-Experiential Inventory and the Big Five, and used them as controls in regression analysis. PMID:27713710

  18. Cognitive Reflection, Decision Biases, and Response Times.

    PubMed

    Alós-Ferrer, Carlos; Garagnani, Michele; Hügelschäfer, Sabine

    2016-01-01

    We present novel evidence on response times and personality traits in standard questions from the decision-making literature where responses are relatively slow (medians around half a minute or above). To this end, we measured response times in a number of incentivized, framed items (decisions from description) including the Cognitive Reflection Test, two additional questions following the same logic, and a number of classic questions used to study decision biases in probability judgments (base-rate neglect, the conjunction fallacy, and the ratio bias). All questions create a conflict between an intuitive process and more deliberative thinking. For each item, we then created a non-conflict version by either making the intuitive impulse correct (resulting in an alignment question), shutting it down (creating a neutral question), or making it dominant (creating a heuristic question). For CRT questions, the differences in response times are as predicted by dual-process theories, with alignment and heuristic variants leading to faster responses and neutral questions to slower responses than the original, conflict questions. For decision biases (where responses are slower), evidence is mixed. To explore the possible influence of personality factors on both choices and response times, we used standard personality scales including the Rational-Experiential Inventory and the Big Five, and used them as controls in regression analysis.

  19. Advanced structural analysis of nanoporous materials by thermal response measurements.

    PubMed

    Oschatz, Martin; Leistner, Matthias; Nickel, Winfried; Kaskel, Stefan

    2015-04-07

    Thermal response measurements based on optical adsorption calorimetry are presented as a versatile tool for the time-saving and profound characterization of the pore structure of porous carbon-based materials. This technique measures the time-resolved temperature change of an adsorbent during adsorption of a test gas. Six carbide and carbon materials with well-defined nanopore architecture including micro- and/or mesopores are characterized by thermal response measurements based on n-butane and carbon dioxide as the test gases. With this tool, the pore systems of the model materials can be clearly distinguished and accurately analyzed. The obtained calorimetric data are correlated with the adsorption/desorption isotherms of the materials. The pore structures can be estimated from a single experiment due to different adsorption enthalpies/temperature increases in micro- and mesopores. Adsorption/desorption cycling of n-butane at 298 K/1 bar with increasing desorption time allows to determine the pore structure of the materials in more detail due to different equilibration times. Adsorption of the organic test gas at selected relative pressures reveals specific contributions of particular pore systems to the increase of the temperature of the samples and different adsorption mechanisms. The use of carbon dioxide as the test gas at 298 K/1 bar provides detailed insights into the ultramicropore structure of the materials because under these conditions the adsorption of this test gas is very sensitive to the presence of pores smaller than 0.7 nm.

  20. THE LICK AGN MONITORING PROJECT: BROAD-LINE REGION RADII AND BLACK HOLE MASSES FROM REVERBERATION MAPPING OF Hbeta

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bentz, Misty C.; Walsh, Jonelle L.; Barth, Aaron J.

    2009-11-01

    We have recently completed a 64-night spectroscopic monitoring campaign at the Lick Observatory 3-m Shane telescope with the aim of measuring the masses of the black holes in 12 nearby (z < 0.05) Seyfert 1 galaxies with expected masses in the range approx10{sup 6}-10{sup 7} M {sub sun} and also the well-studied nearby active galactic nucleus (AGN) NGC 5548. Nine of the objects in the sample (including NGC 5548) showed optical variability of sufficient strength during the monitoring campaign to allow for a time lag to be measured between the continuum fluctuations and the response to these fluctuations in themore » broad Hbeta emission. We present here the light curves for all the objects in this sample and the subsequent Hbeta time lags for the nine objects where these measurements were possible. The Hbeta lag time is directly related to the size of the broad-line region (BLR) in AGNs, and by combining the Hbeta lag time with the measured width of the Hbeta emission line in the variable part of the spectrum, we determine the virial mass of the central supermassive black hole in these nine AGNs. The absolute calibration of the black hole masses is based on the normalization derived by Onken et al., which brings the masses determined by reverberation mapping into agreement with the local M {sub BH}-sigma{sub *}relationship for quiescent galaxies. We also examine the time lag response as a function of velocity across the Hbeta line profile for six of the AGNs. The analysis of four leads to rather ambiguous results with relatively flat time lags as a function of velocity. However, SBS 1116+583A exhibits a symmetric time lag response around the line center reminiscent of simple models for circularly orbiting BLR clouds, and Arp 151 shows an asymmetric profile that is most easily explained by a simple gravitational infall model. Further investigation will be necessary to fully understand the constraints placed on the physical models of the BLR by the velocity-resolved response in these objects.« less

  1. Responsive space: Concept analysis and theoretical framework

    NASA Astrophysics Data System (ADS)

    Saleh, Joseph H.; Dubos, Gregory F.

    2009-08-01

    Customers' needs are dynamic and evolve in response to unfolding environmental uncertainties. The ability of a company or an industry to address these changing customers' needs in a timely and cost-effective way is a measure of its responsiveness. In the space industry, a systemic discrepancy exists between the time constants associated with the change of customers' needs, and the response time of the industry in delivering on-orbit solutions to these needs. There are important penalties associated with such delays, and space responsiveness is recognized as a strategic imperative in commercial competitive and military environments. In this paper, we provide a critical assessment of the literature on responsive space and introduce a new multi-disciplinary framework for thinking about and addressing issues of space responsiveness. Our framework advocates three levels of responsiveness: a global industry-wide responsiveness, a local stakeholder responsiveness, and an interactive or inter-stakeholder responsiveness. We introduce and motivate the use of "responsiveness maps" for multiple stakeholders. We then identify "levers of responsiveness": technical spacecraft- and launch-centric, as well as "soft" levers (e.g., acquisition policies) for improving the responsiveness of the space industry. Finally, we propose a series of research questions to aggressively tackle problems associated with space responsiveness.

  2. Finding Outbreaks Faster

    PubMed Central

    Smolinski, Mark S.; Olsen, Jennifer M.

    2017-01-01

    Rapid detection, reporting, and response to an infectious disease outbreak are critical to prevent localized health events from emerging as pandemic threats. Metrics to evaluate the timeliness of these critical activities, however, are lacking. Easily understood and comparable measures for tracking progress and encouraging investment in rapid detection, reporting, and response are sorely needed. We propose that the timeliness of outbreak detection, reporting, laboratory confirmation, response, and public communication should be considered as measures for improving global health security at the national level, allowing countries to track progress over time and inform investments in disease surveillance. PMID:28384035

  3. Impaired Response Selection During Stepping Predicts Falls in Older People-A Cohort Study.

    PubMed

    Schoene, Daniel; Delbaere, Kim; Lord, Stephen R

    2017-08-01

    Response inhibition, an important executive function, has been identified as a risk factor for falls in older people. This study investigated whether step tests that include different levels of response inhibition differ in their ability to predict falls and whether such associations are mediated by measures of attention, speed, and/or balance. A cohort study with a 12-month follow-up was conducted in community-dwelling older people without major cognitive and mobility impairments. Participants underwent 3 step tests: (1) choice stepping reaction time (CSRT) requiring rapid decision making and step initiation; (2) inhibitory choice stepping reaction time (iCSRT) requiring additional response inhibition and response-selection (go/no-go); and (3) a Stroop Stepping Test (SST) under congruent and incongruent conditions requiring conflict resolution. Participants also completed tests of processing speed, balance, and attention as potential mediators. Ninety-three of the 212 participants (44%) fell in the follow-up period. Of the step tests, only components of the iCSRT task predicted falls in this time with the relative risk per standard deviation for the reaction time (iCSRT-RT) = 1.23 (95%CI = 1.10-1.37). Multiple mediation analysis indicated that the iCSRT-RT was independently associated with falls and not mediated through slow processing speed, poor balance, or inattention. Combined stepping and response inhibition as measured in a go/no-go test stepping paradigm predicted falls in older people. This suggests that integrity of the response-selection component of a voluntary stepping response is crucial for minimizing fall risk. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  4. Mentally simulated movements in virtual reality: does Fitts's law hold in motor imagery?

    PubMed

    Decety, J; Jeannerod, M

    1995-12-14

    This study was designed to investigate mentally simulated actions in a virtual reality environment. Naive human subjects (n = 15) were instructed to imagine themselves walking in a three-dimensional virtual environment toward gates of different apparent widths placed at three different apparent distances. Each subject performed nine blocks of six trials in a randomised order. The response time (reaction time and mental walking time) was measured as the duration between an acoustic go signal and a motor signal produced by the subject. There was a combined effect on response time of both gate width and distance. Response time increased for decreasing apparent gate widths when the gate was placed at different distances. These results support the notion that mentally simulated actions are governed by central motor rules.

  5. Comparing temporal order judgments and choice reaction time tasks as indices of exogenous spatial cuing.

    PubMed

    Eskes, Gail A; Klein, Raymond M; Dove, Mary Beth; Coolican, Jamesie; Shore, David I

    2007-11-30

    Attentional disorders are common in individuals with neurological or psychiatric conditions and impact on recovery and outcome. Thus, it is critical to develop theory-based measures of attentional function to understand potential mechanisms underlying the disorder and to evaluate the effect of intervention. The present study compared two alternative methods to measure the effects of attentional cuing that could be used in populations of individuals who may not be able to make manual responses normally or may show overall slowing in responses. Spatial attention was measured with speeded and unspeeded methods using either manual or voice responses in two standard attention paradigms: the cued target discrimination reaction time (RT) paradigm and the unspeeded temporal order judgment (TOJ) task. The comparison of speeded and unspeeded tasks specifically addresses the concern about interpreting RT differences between cued and uncued trials (taken as a proxy for attention) in the context of drastically different baseline RTs. We found significant cuing effects for both tasks (speeded RT and untimed TOJ) and both response types (vocal and manual) giving clinicians and researchers alternative methods with which to measure the effects of attention in different populations who may not be able to perform the standard speeded RT task.

  6. Metabolic Imaging in Multiple Time Scales

    PubMed Central

    Ramanujan, V Krishnan

    2013-01-01

    We report here a novel combination of time-resolved imaging methods for probing mitochondrial metabolism multiple time scales at the level of single cells. By exploiting a mitochondrial membrane potential reporter fluorescence we demonstrate the single cell metabolic dynamics in time scales ranging from milliseconds to seconds to minutes in response to glucose metabolism and mitochondrial perturbations in real time. Our results show that in comparison with normal human mammary epithelial cells, the breast cancer cells display significant alterations in metabolic responses at all measured time scales by single cell kinetics, fluorescence recovery after photobleaching and by scaling analysis of time-series data obtained from mitochondrial fluorescence fluctuations. Furthermore scaling analysis of time-series data in living cells with distinct mitochondrial dysfunction also revealed significant metabolic differences thereby suggesting the broader applicability (e.g. in mitochondrial myopathies and other metabolic disorders) of the proposed strategies beyond the scope of cancer metabolism. We discuss the scope of these findings in the context of developing portable, real-time metabolic measurement systems that can find applications in preclinical and clinical diagnostics. PMID:24013043

  7. Using the thermal infrared multispectral scanner (TIMS) to estimate surface thermal responses

    NASA Technical Reports Server (NTRS)

    Luvall, J. C.; Holbo, H. R.

    1987-01-01

    A series of measurements was conducted over the H.J. Andrews, Oregon, experimental coniferous forest, using airborne thermal infrared multispectral scanner (TIMS). Flight lines overlapped, with a 28-min time difference between flight lines. Concurrent radiosonde measurements of atmospheric profiles of air temperature and moisture were used for atmospheric radiance corrections of the TIMS data. Surface temperature differences over time between flight lines were used to develop thermal response numbers (TRNs) which characterized the thermal response (in KJ/sq m/C, where K is the measured incoming solar radiation) of the different surface types. The surface types included a mature forest (canopy dominated by dense crowns of Pseudosuga menziesii, with a secondary canopy of dense Tsuga heterophylla, and also a tall shrub layer of Acer circinatum) and a two-year-old clear-cut. The temperature distribution, within TIMS thermal images was found to reflect the surface type examined. The clear-cut surface had the lowest TRN, while mature Douglas fir the highest.

  8. Visual-motor response of crewmen during a simulated 90-day space mission as measured by the critical task battery

    NASA Technical Reports Server (NTRS)

    Allen, R. W.; Jex, H. R.

    1973-01-01

    In order to test various components of a regenerative life support system and to obtain data on the physiological and psychological effects of long duration exposure to confinement in a space station atmosphere, four carefully screened young men were sealed in a space station simulator for 90 days and administered a tracking test battery. The battery included a clinical test (Critical Instability Task) designed to measure a subject's dynamic time delay, and a more conventional steady tracking task, during which dynamic response (describing functions) and performance measures were obtained. Good correlation was noted between the clinical critical instability scores and more detailed tracking parameters such as dynamic time delay and gain-crossover frequency. The levels of each parameter span the range observed with professional pilots and astronaut candidates tested previously. The chamber environment caused no significant decrement on the average crewman's dynamic response behavior, and the subjects continued to improve slightly in their tracking skills during the 90-day confinement period.

  9. A kernel-based novelty detection scheme for the ultra-fast detection of chirp evoked Auditory Brainstem Responses.

    PubMed

    Corona-Strauss, Farah I; Delb, Wolfgang; Schick, Bernhard; Strauss, Daniel J

    2010-01-01

    Auditory Brainstem Responses (ABRs) are used as objective method for diagnostics and quantification of hearing loss. Many methods for automatic recognition of ABRs have been developed, but none of them include the individual measurement setup in the analysis. The purpose of this work was to design a fast recognition scheme for chirp-evoked ABRs that is adjusted to the individual measurement condition using spontaneous electroencephalographic activity (SA). For the classification, the kernel-based novelty detection scheme used features based on the inter-sweep instantaneous phase synchronization as well as energy and entropy relations in the time-frequency domain. This method provided SA discrimination from stimulations above the hearing threshold with a minimum number of sweeps, i.e., 200 individual responses. It is concluded that the proposed paradigm, processing procedures and stimulation techniques improve the detection of ABRs in terms of the degree of objectivity, i.e., automation of procedure, and measurement time.

  10. Effect of sleep deficit, knowledge of results, and stimulus quality on reaction time and response force.

    PubMed

    Jaśkowski, P; Włodarczyk, D

    1997-04-01

    Some recent findings suggested that response force measured during reaction time experiments might reflect changes in activation. We performed an experiment in which the effect of sleep deprivation, knowledge of results, and stimulus quality on response force was studied in simple and choice reaction tasks. As expected, both simple and choice reaction times increased with sleep deficit. Further, simple and choice reactions were faster with knowledge of results and slowed down when stimulus quality was degraded. As sleep deprivation affects both arousal and activation, we expected a detrimental effect of sleep on force amplitude. On the other hand, knowledge of results was expected to increase force by its compensatory effect on arousal and activation. No effect of sleep deprivation on response force was found. Knowledge of results increased response force independently of sleep deprivation.

  11. Förster resonance energy transfer (FRET)-based picosecond lifetime reference for instrument response evaluation

    NASA Astrophysics Data System (ADS)

    Luchowski, R.; Kapusta, P.; Szabelski, M.; Sarkar, P.; Borejdo, J.; Gryczynski, Z.; Gryczynski, I.

    2009-09-01

    Förster resonance energy transfer (FRET) can be utilized to achieve ultrashort fluorescence responses in time-domain fluorometry. In a poly(vinyl) alcohol matrix, the presence of 60 mM Rhodamine 800 acceptor shortens the fluorescence lifetime of a pyridine 1 donor to about 20 ps. Such a fast fluorescence response is very similar to the instrument response function (IRF) obtained using scattered excitation light. A solid fluorescent sample (e.g a film) with picosecond lifetime is ideal for IRF measurements and particularly useful for time-resolved microscopy. Avalanche photodiode detectors, commonly used in this field, feature color- dependent-timing responses. We demonstrate that recording the fluorescence decay of the proposed FRET-based reference sample yields a better IRF approximation than the conventional light-scattering method and therefore avoids systematic errors in decay curve analysis.

  12. LabVIEW-based control and data acquisition system for cathodoluminescence experiments.

    PubMed

    Bok, J; Schauer, P

    2011-11-01

    Computer automation of cathodoluminescence (CL) experiments using equipment developed in our laboratory is described. The equipment provides various experiments for CL efficiency, CL spectra, and CL time response studies. The automation was realized utilizing the graphical programming environment LabVIEW. The developed application software with procedures for equipment control and data acquisition during various CL experiments is presented. As the measured CL data are distorted by technical limitations of the equipment, such as equipment spectral sensitivity and time response, data correction algorithms were incorporated into the procedures. Some examples of measured data corrections are presented. © 2011 American Institute of Physics

  13. A new broadband square law detector. [microwave radiometers

    NASA Technical Reports Server (NTRS)

    Reid, M. S.; Gardner, R. A.; Stelzried, C. T.

    1975-01-01

    A broadband constant law detector was developed for precision power measurements, radio metric measurements, and other applications. It has a wide dynamic range and an accurate square law response. Other desirable characteristics, which are all included in a single compact unit, are: (1) high-level dc output with immunity to ground loop problems; (2) fast response times; (3) ability to insert known time constants; and (4) good thermal stability. The detector and its performance are described in detail. The detector can be operated in a programmable system with a ten-fold increase in accuracy. The use and performance of the detector in a noise-adding radiometer system is also discussed.

  14. Validity and Responsiveness of the Two-Minute Walk Test for Measuring Functional Recovery After Total Knee Arthroplasty.

    PubMed

    Unnanuntana, Aasis; Ruangsomboon, Pakpoom; Keesukpunt, Worawut

    2018-06-01

    The 2-minute walk test (2mwt) is a performance-based test that evaluates functional recovery after total knee arthroplasty (TKA). This study evaluated its validity compared with the modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), modified Knee Score, Numerical Pain Rating Scale, and Timed Up and Go test, and its responsiveness in assessing functional recovery in TKA patients. This prospective cohort study included 162 patients undergoing primary TKA between 2013 and 2015. We used patient-reported outcome measures (modified WOMAC, OKS, modified Knee Score, Numerical Pain Rating Scale) and performance-based tests (2mwt and Timed Up and Go test) at baseline and 3, 6, and 12 months postoperatively. The construct validity of 2mwt was determined between the 2mwt distances walked and other outcome measurements. To assess responsiveness, effect size and standardized response mean were analyzed. Minimal clinically important difference of 2mwt at 12 months after TKA was also calculated. All outcome measurements improved significantly from baseline to 3, 6, and 12 months postoperatively. Bivariate analysis revealed mild to moderate associations between the 2mwt and modified WOMAC function subscales, and moderate to strong associations with OKS. Mild to moderate correlations were found for pain and stiffness between 2mwt and other outcome measurements. The effect size and standardized response mean at 12 months were large, with a minimal clinically important difference of 12.7 m. 2mwt is a validated performance-based test with responsiveness properties. Being simple and easy to perform, it can be used routinely in clinical practice to evaluate functional recovery after TKA. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Even Shallower Exploration with Airborne Electromagnetics

    NASA Astrophysics Data System (ADS)

    Auken, E.; Christiansen, A. V.; Kirkegaard, C.; Nyboe, N. S.; Sørensen, K.

    2015-12-01

    Airborne electromagnetics (EM) is in many ways undergoing the same type rapid technological development as seen in the telecommunication industry. These developments are driven by a steadily increasing demand for exploration of minerals, groundwater and geotechnical targets. The latter two areas demand shallow and accurate resolution of the near surface geology in terms of both resistivity and spatial delineation of the sedimentary layers. Airborne EM systems measure the grounds electromagnetic response when subject to either a continuous discrete sinusoidal transmitter signal (frequency domain) or by measuring the decay of currents induced in the ground by rapid transmission of transient pulses (time domain). In the last decade almost all new developments of both instrument hardware and data processing techniques has focused around time domain systems. Here we present a concept for measuring the time domain response even before the transient transmitter current has been turned off. Our approach relies on a combination of new instrument hardware and novel modeling algorithms. The newly developed hardware allows for measuring the instruments complete transfer function which is convolved with the synthetic earth response in the inversion algorithm. The effect is that earth response data measured while the transmitter current is turned off can be included in the inversion, significantly increasing the amount of available information. We demonstrate the technique using both synthetic and field data. The synthetic examples provide insight on the physics during the turn off process and the field examples document the robustness of the method. Geological near surface structures can now be resolved to a degree that is unprecedented to the best of our knowledge, making airborne EM even more attractive and cost-effective for exploration of water and minerals that are crucial for the function of our societies.

  16. Switched integration amplifier-based photocurrent meter for accurate spectral responsivity measurement of photometers.

    PubMed

    Park, Seongchong; Hong, Kee-Suk; Kim, Wan-Seop

    2016-03-20

    This work introduces a switched integration amplifier (SIA)-based photocurrent meter for femtoampere (fA)-level current measurement, which enables us to measure a 107 dynamic range of spectral responsivity of photometers even with a common lamp-based monochromatic light source. We described design considerations and practices about operational amplifiers (op-amps), switches, readout methods, etc., to compose a stable SIA of low offset current in terms of leakage current and gain peaking in detail. According to the design, we made six SIAs of different integration capacitance and different op-amps and evaluated their offset currents. They showed an offset current of (1.5-85) fA with a slow variation of (0.5-10) fA for an hour under opened input. Applying a detector to the SIA input, the offset current and its variation were increased and the SIA readout became noisier due to finite shunt resistance and nonzero shunt capacitance of the detector. One of the SIAs with 10 pF nominal capacitance was calibrated using a calibrated current source at the current level of 10 nA to 1 fA and at the integration time of 2 to 65,536 ms. As a result, we obtained a calibration formula for integration capacitance as a function of integration time rather than a single capacitance value because the SIA readout showed a distinct dependence on integration time at a given current level. Finally, we applied it to spectral responsivity measurement of a photometer. It is demonstrated that the home-made SIA of 10 pF was capable of measuring a 107 dynamic range of spectral responsivity of a photometer.

  17. Enhanced Photoacoustic Gas Analyser Response Time and Impact on Accuracy at Fast Ventilation Rates during Multiple Breath Washout

    PubMed Central

    Horsley, Alex; Macleod, Kenneth; Gupta, Ruchi; Goddard, Nick; Bell, Nicholas

    2014-01-01

    Background The Innocor device contains a highly sensitive photoacoustic gas analyser that has been used to perform multiple breath washout (MBW) measurements using very low concentrations of the tracer gas SF6. Use in smaller subjects has been restricted by the requirement for a gas analyser response time of <100 ms, in order to ensure accurate estimation of lung volumes at rapid ventilation rates. Methods A series of previously reported and novel enhancements were made to the gas analyser to produce a clinically practical system with a reduced response time. An enhanced lung model system, capable of delivering highly accurate ventilation rates and volumes, was used to assess in vitro accuracy of functional residual capacity (FRC) volume calculation and the effects of flow and gas signal alignment on this. Results 10–90% rise time was reduced from 154 to 88 ms. In an adult/child lung model, accuracy of volume calculation was −0.9 to 2.9% for all measurements, including those with ventilation rate of 30/min and FRC of 0.5 L; for the un-enhanced system, accuracy deteriorated at higher ventilation rates and smaller FRC. In a separate smaller lung model (ventilation rate 60/min, FRC 250 ml, tidal volume 100 ml), mean accuracy of FRC measurement for the enhanced system was minus 0.95% (range −3.8 to 2.0%). Error sensitivity to flow and gas signal alignment was increased by ventilation rate, smaller FRC and slower analyser response time. Conclusion The Innocor analyser can be enhanced to reliably generate highly accurate FRC measurements down at volumes as low as those simulating infant lung settings. Signal alignment is a critical factor. With these enhancements, the Innocor analyser exceeds key technical component recommendations for MBW apparatus. PMID:24892522

  18. Relationship between Measures of Working Memory Capacity and the Time Course of Short-Term Memory Retrieval and Interference Resolution

    ERIC Educational Resources Information Center

    Oztekin, Ilke; McElree, Brian

    2010-01-01

    The response-signal speed-accuracy trade-off (SAT) procedure was used to investigate the relationship between measures of working memory capacity and the time course of short-term item recognition. High- and low-span participants studied sequentially presented 6-item lists, immediately followed by a recognition probe. Analyses of composite list…

  19. Measuring Food Use in School-Aged Children.

    ERIC Educational Resources Information Center

    Randall, Elizabeth

    1991-01-01

    Ideal measurement of food use in school-aged children possesses validity, reliability, interpretability, and feasibility. The article discusses dietary records and recalls and measures of patterns in food use. Issues to consider when constructing children's food frequency are food list, time intervals, response set, context of questioning, and…

  20. Evaluation of responses to vaccination of Angus cattle for four viruses that contribute to bovine respiratory disease complex.

    PubMed

    Kramer, L M; Mayes, M S; Fritz-Waters, E; Williams, J L; Downey, E D; Tait, R G; Woolums, A; Chase, C; Reecy, J M

    2017-11-01

    Although vaccination is an effective measure in reducing the risk of bovine respiratory disease complex (BRDC) in cattle, BRDC losses remain significant. Increasing the efficacy of vaccination depends on elucidating the protective immune response to different antigens included in vaccines, determining the best timing for vaccination, and understanding the impact of the age of the calf on vaccination. This study measured the serum antibodies present in calves following vaccination against 4 viruses commonly associated with BRDC: bovine viral diarrhea virus type 1 and 2 (BVDV1 and BVDV2), bovine respiratory syncytial virus (BRSV), and bovine herpesvirus 1 (BHV1). Serum antibody titers were measured in more than 1,600 calves at 3-wk intervals starting at the time of the first vaccination. This first vaccination occurred at weaning for approximately half of the individuals and 3 wk before weaning for the other half. Dam age (years), time of weaning (initial vaccination or booster vaccination), and age of calf within year-season (days within year-season) classification all were found to have a significant effect on measured traits such as the initial titer and overall response. An increased initial titer was negatively correlated with each response trait (initial, booster, and overall response). Calves that were weaned at initial vaccination had greater overall antibody response to BVDV1 and BVDV2 compared with calves weaned 3 wk before initial vaccination. In contrast, calves given their initial vaccination 3 wk before weaning had greater overall antibody response to BRSV and BHV1 compared with calves that were vaccinated at weaning. Furthermore, the circulating antibody titer at which each virus needed to be below for an individual calf to positively respond to vaccination was determined (log titer of 0.38 for BVDV1, 1.5 for BVDV2, 3.88 for BRSV, and 1.5 for BHV1). This information can be used to improve vaccination protocols to allow for a greater response rate of individuals to vaccination and, hopefully, improved protection.

  1. A calibration-free electrode compensation method

    PubMed Central

    Rossant, Cyrille; Fontaine, Bertrand; Magnusson, Anna K.

    2012-01-01

    In a single-electrode current-clamp recording, the measured potential includes both the response of the membrane and that of the measuring electrode. The electrode response is traditionally removed using bridge balance, where the response of an ideal resistor representing the electrode is subtracted from the measurement. Because the electrode is not an ideal resistor, this procedure produces capacitive transients in response to fast or discontinuous currents. More sophisticated methods exist, but they all require a preliminary calibration phase, to estimate the properties of the electrode. If these properties change after calibration, the measurements are corrupted. We propose a compensation method that does not require preliminary calibration. Measurements are compensated offline by fitting a model of the neuron and electrode to the trace and subtracting the predicted electrode response. The error criterion is designed to avoid the distortion of compensated traces by spikes. The technique allows electrode properties to be tracked over time and can be extended to arbitrary models of electrode and neuron. We demonstrate the method using biophysical models and whole cell recordings in cortical and brain-stem neurons. PMID:22896724

  2. Inmate responses to prison-based drug treatment: a repeated measures analysis.

    PubMed

    Welsh, Wayne N

    2010-06-01

    Using a sample of 347 prison inmates and general linear modeling (GLM) repeated measures analyses, this paper examined during-treatment responses (e.g., changes in psychological and social functioning) to prison-based TC drug treatment. These effects have rarely been examined in previous studies, and never with a fully multivariate model accounting for within-subjects effects (changes over time), between-subjects effects (e.g., levels of risk and motivation), and within/between-subjects interactions (timexriskxmotivation). The results provide evidence of positive inmate change in response to prison TC treatment, but the patterns of results varied depending upon: (a) specific indicators of psychological and social functioning, motivation, and treatment process; (b) the time periods examined (1, 6, and 12 months during treatment); and (c) baseline levels of risk and motivation. Significant interactions between time and type of inmate suggest important new directions for research, theory, and practice in offender-based substance abuse treatment. Copyright (c) 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Underlying neural alpha frequency patterns associated with intra-hemispheric inhibition during an interhemispheric transfer task.

    PubMed

    Simon-Dack, Stephanie L; Kraus, Brian; Walter, Zachary; Smith, Shelby; Cadle, Chelsea

    2018-05-18

    Interhemispheric transfer measured via differences in right- or left-handed motoric responses to lateralized visual stimuli, known as the crossed-uncrossed difference (CUD), is one way of identifying patterns of processing that are vital for understanding the transfer of neural signals. Examination of interhemispheric transfer by means of the CUD is not entirely explained by simple measures of response time. Multiple processes contribute to wide variability observed in CUD reaction times. Prior research has suggested that intra-hemispheric inhibitory processes may be involved in regulation of speed of transfer. Our study examined electroencephalography recordings and time-locked alpha frequency activity while 18 participants responded to lateralized targets during performance of the Poffenberger Paradigm. Our results suggest that there are alpha frequency differences at fronto-central lateral electrodes based on target, hand-of-response, and receiving hemisphere. These findings suggest that early motoric inhibitory mechanisms may help explain the wide range of variability typically seen with the CUD. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Measurement of the acoustic response of a wind instrument with application to bore reconstruction

    NASA Astrophysics Data System (ADS)

    van Walstijn, Maarten; Campbell, Murray

    2002-11-01

    Reconstruction of a bore from measured acoustic response data has been shown to be very useful in studying wind instruments. Such data may be obtained in different ways; directly measuring the frequency-domain response of an acoustic bore has some distinct advantages over directly measuring time-domain data (for example, by pulse reflectometry), but so far has been unsuitable for producing input data for deterministic bore reconstruction algorithms, due to the limited accuracy at high frequencies. In this paper a method is presented for large-bandwidth measurement of the input impedance of a wind instrument using a cylindrical measurement head with multiple wall-mounted microphones. The influence of the number of microphones and the types of calibration impedance on the accuracy will be discussed, and bore reconstructions derived using this technique will be compared with reconstructions obtained using pulse reflectometry. [Work supported by EPSRC.

  5. Near-Surface Geophysical Mapping of the Hydrological Response to an Intense Rainfall Event at the Field Scale

    NASA Astrophysics Data System (ADS)

    Martínez, G.; Vanderlinden, K.; Giraldez, J. V.; Espejo, A. J.; Muriel, J. L.

    2009-12-01

    Soil moisture plays an important role in a wide variety of biogeochemical fluxes in the soil-plant-atmosphere system and governs the (eco)hydrological response of a catchment to an external forcing such as rainfall. Near-surface electromagnetic induction (EMI) sensors that measure the soil apparent electrical conductivity (ECa) provide a fast and non-invasive means for characterizing this response at the field or catchment scale through high-resolution time-lapse mapping. Here we show how ECa maps, obtained before and after an intense rainfall event of 125 mm h-1, elucidate differences in soil moisture patterns and hydrologic response of an experimental field as a consequence of differed soil management. The dryland field (Vertisol) was located in SW Spain and cropped with a typical wheat-sunflower-legume rotation. Both, near-surface and subsurface ECa (ECas and ECad, respectively), were measured using the EM38-DD EMI sensor in a mobile configuration. Raw ECa measurements and Mean Relative Differences (MRD) provided information on soil moisture patterns while time-lapse maps were used to evaluate the hydrologic response of the field. ECa maps of the field, measured before and after the rainfall event showed similar patterns. The field depressions where most of water and sediments accumulated had the highest ECa and MRD values. The SE-oriented soil, which was deeper and more exposed to sun and wind, showed the lowest ECa and MRD. The largest differences raised in the central part of the field where a high ECa and MRD area appeared after the rainfall event as a consequence of the smaller soil depth and a possible subsurface flux concentration. Time-lapse maps of both ECa and MRD were also similar. The direct drill plots showed higher increments of ECa and MRD as a result of the smaller runoff production. Time-lapse ECa increments showed a bimodal distribution differentiating clearly the direct drill from the conventional and minimum tillage plots. However this kind of distribution could not be shown using MRD differences since they come from standardized distributions. Field-extend time-lapse ECa maps can provide useful images of the hydrological response of agricultural fields which can be used to evaluate different soil management strategies or to aid the assessment of biogeochemical fluxes at the field scale.

  6. New aspects of the ionospheric response to the October 2003 superstorms from multiple-satellite observations

    NASA Astrophysics Data System (ADS)

    Lei, Jiuhou; Wang, Wenbin; Burns, Alan G.; Yue, Xinan; Dou, Xiankang; Luan, Xiaoli; Solomon, Stanley C.; Liu, Yong C.-M.

    2014-03-01

    The total electron content (TEC) data measured by the Jason, CHAMP, GRACE, and SAC-C satellites, the in situ electron densities from CHAMP and GRACE, and the vertical E × B drifts from the ROCSAT, have been utilized to examine the ionospheric response to the October 2003 superstorms. The combination of observations from multiple satellites provides a unique global view of ionospheric storm effects, especially over the Pacific Ocean and American regions, which were under sunlit conditions during the main phases of the October 2003 superstorms. The main results of this study are as follows: (1) There were substantial increases in TEC in the daytime at low and middle latitudes during both superstorms. (2) The enhancements were greater during the 30 October superstorm and occurred over a wider range of local times. (3) They also tended to peak at earlier local times during this second event. (4) These TEC enhancement events occurred at the local times when there were enhancements in the upward vertical drift. (5) The strong upward vertical drifts are attributed to penetration electric fields, suggesting that these penetration electric fields played a significant role in the electron density enhancements during these superstorms. Overall, the main contribution of this study is the simultaneous view of the storm time ionospheric response from multiple satellites, and the association of local time differences in ionospheric plasma response with measured vertical drift variations.

  7. Third-order optical nonlinearities of sol-gel silica coating films containing metal porphyrin derivatives measured by resonant femtosecond degenerate four-wave mixing technique

    NASA Astrophysics Data System (ADS)

    Kasatani, Kazuo; Okamoto, Hiroaki; Takenaka, Shunsuke

    2003-11-01

    Third-order optical nonlinearities of sol-gel silica coating films containing metal porphyrin derivatives were measured under resonant conditions by the femtosecond degenerate four-wave mixing (DFWM) technique. Temporal profiles of the DFWM signal were measured with a time resolution of 0.3 ps, and were found to consist of two components, the coherent instantaneous nonlinear response and the delayed response with a decay time constant of several to several hundred ps. The latter can be attributed to population grating of an excited state, and contribution of slow component was very little for a zinc porphyrin derivative. The values of electronic component of the optical nonlinear susceptibility, χ(3) xxxx, for these films were ca. 2 x 10-10 esu.

  8. [Effects of an implicit internal working model on attachment in information processing assessed using Go/No-Go Association Task].

    PubMed

    Fujii, Tsutomu; Uebuchi, Hisashi; Yamada, Kotono; Saito, Masahiro; Ito, Eriko; Tonegawa, Akiko; Uebuchi, Marie

    2015-06-01

    The purposes of the present study were (a) to use both a relational-anxiety Go/No-Go Association Task (GNAT) and an avoidance-of-intimacy GNAT in order to assess an implicit Internal Working Model (IWM) of attachment; (b) to verify the effects of both measured implicit relational anxiety and implicit avoidance of intimacy on information processing. The implicit IWM measured by GNAT differed from the explicit IWM measured by questionnaires in terms of the effects on information processing. In particular, in subliminal priming tasks involving with others, implicit avoidance of intimacy predicted accelerated response times with negative stimulus words about attachment. Moreover, after subliminally priming stimulus words about self, implicit relational anxiety predicted delayed response times with negative stimulus words about attachment.

  9. Defining Hepatoblastoma Responsiveness to Induction Therapy as Measured by Tumor Volume and Serum α-fetoprotein Kinetics

    PubMed Central

    Lovvorn, Harold N.; Ayers, Dan; Zhao, Zhiguo; Hilmes, Melissa; Prasad, Pinki; Shinall, Myrick C.; Berch, Barry; Neblett, Wallace W.; O'Neill, James A.

    2010-01-01

    Purpose Hepatoblastoma is commonly unresectable at presentation, necessitating induction chemotherapy before definitive resection. To refine the paradigm for timing of resection, we questioned whether a plateau in hepatoblastoma responsiveness to neoadjuvant therapy could be detected by calculating tumor volume (TV) and serum α-fetoprotein (sAFP) kinetics. Methods To calculate TV and sAFP as measures of treatment responsiveness over time, infants having initially unresectable epithelial-type hepatoblastomas were identified at a single institution (1996-2008). Effects of therapy type, therapy duration, and lobe of liver involvement on TV, sAFP, margin status, and toxicity were analyzed. Results Of 24 infants treated for epithelial-type hepatoblastoma during this interval, 5 were resected primarily, and 15 had complete digital films for kinetics analysis. Both TV and sAFP decreased dramatically over time (p<0.0001). No statistically significant difference in mean TV or sAFP was detected after chemotherapy cycle 2. Left lobe tumors had greater presenting levels of and significantly slower decay in sAFP compared to right lobe tumors (p=0.005), although no statistically significant differences in TV existed between liver lobes. Resection margins did not change with therapy duration. Conclusions Measuring TV and sAFP kinetics accurately reflects hepatoblastoma responsiveness to induction therapy. Treatment toxicities may be reduced by earlier resection and tailoring of chemotherapeutic regimens. PMID:20105591

  10. Linking Tree Growth Response to Measured Microclimate - A Field Based Approach

    NASA Astrophysics Data System (ADS)

    Martin, J. T.; Hoylman, Z. H.; Looker, N. T.; Jencso, K. G.; Hu, J.

    2015-12-01

    The general relationship between climate and tree growth is a well established and important tenet shaping both paleo and future perspectives of forest ecosystem growth dynamics. Across much of the American west, water limits growth via physiological mechanisms that tie regional and local climatic conditions to forest productivity in a relatively predictable way, and these growth responses are clearly evident in tree ring records. However, within the annual cycle of a forest landscape, water availability varies across both time and space, and interacts with other potentially growth limiting factors such as temperature, light, and nutrients. In addition, tree growth responses may lag climate drivers and may vary in terms of where in a tree carbon is allocated. As such, determining when and where water actually limits forest growth in real time can be a significant challenge. Despite these challenges, we present data suggestive of real-time growth limitation driven by soil moisture supply and atmospheric water demand reflected in high frequency field measurements of stem radii and cell structure across ecological gradients. The experiment was conducted at the Lubrecht Experimental Forest in western Montana where, over two years, we observed intra-annual growth rates of four dominant conifer species: Douglas fir, Ponderosa Pine, Engelmann Spruce and Western Larch using point dendrometers and microcores. In all four species studied, compensatory use of stored water (inferred from stem water deficit) appears to exhibit a threshold relationship with a critical balance point between water supply and demand. The occurrence of this point in time coincided with a decrease in stem growth rates, and the while the timing varied up to one month across topographic and elevational gradients, the onset date of growth limitation was a reliable predictor of overall annual growth. Our findings support previous model-based observations of nonlinearity in the relationship between climate and annual ring formation, and suggest a rather immediate growth response to critical micro-meteorological conditions occurring at different times across the landscape by linking the timing and magnitude of tree growth responses to in situ measurements of environmental conditions.

  11. Special Tests for Monitoring Fetal Health

    MedlinePlus

    ... a nonstress test? The nonstress test measures the fetal heart rate in response to fetal movement over time. The ... A belt with a sensor that measures the fetal heart rate is placed around your abdomen. The fetal heart ...

  12. Faraday-effect polarimeter diagnostic for internal magnetic field fluctuation measurements in DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, J., E-mail: chenjie@ucla.edu; State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074; Ding, W. X.

    2016-11-15

    Motivated by the need to measure fast equilibrium temporal dynamics, non-axisymmetric structures, and core magnetic fluctuations (coherent and broadband), a three-chord Faraday-effect polarimeter-interferometer system with fast time response and high phase resolution has recently been installed on the DIII-D tokamak. A novel detection scheme utilizing two probe beams and two detectors for each chord results in reduced phase noise and increased time response [δb ∼ 1G with up to 3 MHz bandwidth]. First measurement results were obtained during the recent DIII-D experimental campaign. Simultaneous Faraday and density measurements have been successfully demonstrated and high-frequency, up to 100 kHz, Faraday-effect perturbationsmore » have been observed. Preliminary comparisons with EFIT are used to validate diagnostic performance. Principle of the diagnostic and first experimental results is presented.« less

  13. A review on creatinine measurement techniques.

    PubMed

    Mohabbati-Kalejahi, Elham; Azimirad, Vahid; Bahrami, Manouchehr; Ganbari, Ahmad

    2012-08-15

    This paper reviews the entire recent global tendency for creatinine measurement. Creatinine biosensors involve complex relationships between biology and micro-mechatronics to which the blood is subjected. Comparison between new and old methods shows that new techniques (e.g. Molecular Imprinted Polymers based algorithms) are better than old methods (e.g. Elisa) in terms of stability and linear range. All methods and their details for serum, plasma, urine and blood samples are surveyed. They are categorized into five main algorithms: optical, electrochemical, impedometrical, Ion Selective Field-Effect Transistor (ISFET) based technique and chromatography. Response time, detection limit, linear range and selectivity of reported sensors are discussed. Potentiometric measurement technique has the lowest response time of 4-10 s and the lowest detection limit of 0.28 nmol L(-1) belongs to chromatographic technique. Comparison between various techniques of measurements indicates that the best selectivity belongs to MIP based and chromatographic techniques. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. Method of detecting system function by measuring frequency response

    DOEpatents

    Morrison, John L.; Morrison, William H.; Christophersen, Jon P.; Motloch, Chester G.

    2013-01-08

    Methods of rapidly measuring an impedance spectrum of an energy storage device in-situ over a limited number of logarithmically distributed frequencies are described. An energy storage device is excited with a known input signal, and a response is measured to ascertain the impedance spectrum. An excitation signal is a limited time duration sum-of-sines consisting of a select number of frequencies. In one embodiment, magnitude and phase of each frequency of interest within the sum-of-sines is identified when the selected frequencies and sample rate are logarithmic integer steps greater than two. This technique requires a measurement with a duration of one period of the lowest frequency. In another embodiment, where selected frequencies are distributed in octave steps, the impedance spectrum can be determined using a captured time record that is reduced to a half-period of the lowest frequency.

  15. Imaging through Scattering Media with Grating-Based Interferometers.

    DTIC Science & Technology

    1980-12-01

    Theoretically, if the instantaneous impulse response nf the scat- tering medium can be measured and an inverse filter [7, 8] can be created in real time, it... impulse response of a time- varying volume scattering medium. Moreover, no modulator appears to possess the required temporal and spatial bandwidth for...or optical deblurring techniques. Thirdly, since the achromatic grating interferometric system discriminates by the directions of propa- gation, the

  16. Femtosecond response time measurements of a Cs2Te photocathode

    NASA Astrophysics Data System (ADS)

    Aryshev, A.; Shevelev, M.; Honda, Y.; Terunuma, N.; Urakawa, J.

    2017-07-01

    Success in design and construction of a compact, high-brightness accelerator system is strongly related to the production of ultra-short electron beams. Recently, the approach to generate short electron bunches or pre-bunched beams in RF guns directly illuminating a high quantum efficiency semiconductor photocathode with femtosecond laser pulses has become attractive. The measurements of the photocathode response time in this case are essential. With an approach of the interferometer-type pulse splitter deep integration into a commercial Ti:Sa laser system used for RF guns, it has become possible to generate pre-bunched electron beams and obtain continuously variable electron bunch separation. In combination with a well-known zero-phasing technique, it allows us to estimate the response time of the most commonly used Cs2Te photocathode. It was demonstrated that the peak-to-peak rms time response of Cs2Te is of the order of 370 fs, and thereby, it is possible to generate and control a THz sequence of relativistic electron bunches by a conventional S-band RF gun. This result can also be applied for investigation of other cathode materials and electron beam temporal shaping and further opens a possibility to construct wide-range tunable, table-top THz free electron laser.

  17. Across-Task Priming Revisited: Response and Task Conflicts Disentangled Using Ex-Gaussian Distribution Analysis

    ERIC Educational Resources Information Center

    Moutsopoulou, Karolina; Waszak, Florian

    2012-01-01

    The differential effects of task and response conflict in priming paradigms where associations are strengthened between a stimulus, a task, and a response have been demonstrated in recent years with neuroimaging methods. However, such effects are not easily disentangled with only measurements of behavior, such as reaction times (RTs). Here, we…

  18. Premature responding is associated with approach to a food cue in male and female heterogeneous stock rats.

    PubMed

    King, Christopher P; Palmer, Abraham A; Woods, Leah C Solberg; Hawk, Larry W; Richards, Jerry B; Meyer, Paul J

    2016-07-01

    Disorders of behavioral regulation, including attention deficit hyperactivity disorder (ADHD) and drug addiction, are in part due to poor inhibitory control, attentional deficits, and hyper-responsivity to reward-associated cues. To determine whether these traits are related, we tested genetically variable male and female heterogeneous stock rats in the choice reaction time (CRT) task and Pavlovian conditioned approach (PavCA). Sex differences in the response to methylphenidate during the CRT were also assessed. In the CRT task, rats were required to withhold responding until one of two lights indicated whether responses into a left or right port would be reinforced with water. Reaction time on correct trials and premature responses were the operational definitions of attention and response inhibition, respectively. Rats were also pretreated with oral methylphenidate (0, 2, 4 mg/kg) during the CRT task to determine whether this drug would improve performance. Subsequently, during PavCA, presentation of an illuminated lever predicted the delivery of a food pellet into a food-cup. Lever-directed approach (sign-tracking) and food-cup approach (goal-tracking) were the primary measures, and rats were categorized as "sign-trackers" and "goal-trackers" using an index based on these measures. Sign-trackers made more premature responses than goal-trackers but showed no differences in reaction time. There were sex differences in both tasks, with females having higher sign-tracking, completing more CRT trials, and making more premature responses after methylphenidate administration. These results indicate that response inhibition is related to reward-cue responsivity, suggesting that these traits are influenced by common genetic factors.

  19. Adapting cultural mixture modeling for continuous measures of knowledge and memory fluency.

    PubMed

    Tan, Yin-Yin Sarah; Mueller, Shane T

    2016-09-01

    Previous research (e.g., cultural consensus theory (Romney, Weller, & Batchelder, American Anthropologist, 88, 313-338, 1986); cultural mixture modeling (Mueller & Veinott, 2008)) has used overt response patterns (i.e., responses to questionnaires and surveys) to identify whether a group shares a single coherent attitude or belief set. Yet many domains in social science have focused on implicit attitudes that are not apparent in overt responses but still may be detected via response time patterns. We propose a method for modeling response times as a mixture of Gaussians, adapting the strong-consensus model of cultural mixture modeling to model this implicit measure of knowledge strength. We report the results of two behavioral experiments and one simulation experiment that establish the usefulness of the approach, as well as some of the boundary conditions under which distinct groups of shared agreement might be recovered, even when the group identity is not known. The results reveal that the ability to recover and identify shared-belief groups depends on (1) the level of noise in the measurement, (2) the differential signals for strong versus weak attitudes, and (3) the similarity between group attitudes. Consequently, the method shows promise for identifying latent groups among a population whose overt attitudes do not differ, but whose implicit or covert attitudes or knowledge may differ.

  20. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodward, Stanley E. (Inventor); Taylor, Bryant D. (Inventor)

    2007-01-01

    Magnetic field response sensors designed as passive inductor- capacit or circuits produce magnetic field responses whose harmonic frequenci es correspond to states of physical properties for which the sensors measure. Power to the sensing element is acquired using Faraday induc tion. A radio frequency antenna produces the time varying magnetic fi eld used for powering the sensor, as well as receiving the magnetic field response of the sensor. An interrogation architecture for disce rning changes in sensor's response frequency, resistance and amplitud e is integral to the method thus enabling a variety of measurements. Multiple sensors can be interrogated using this method, thus eliminat ing the need to have a data acquisition channel dedicated to each se nsor. The method does not require the sensors to be in proximity to a ny form of acquisition hardware. A vast array of sensors can be used as interchangeable parts in an overall sensing system.

  1. Effect of the fissile bead's and thermocouple wires' sizes on the response time of a fission couple.

    PubMed

    Liang, Wenfeng; Lu, Yi; Li, Meng; Fan, Xiaoqiang; Lu, Wei

    2014-05-01

    The fission couple is proposed as a fast response miniature neutron detector in the measurement of time dependent energy depositions within the fissile material based on theoretical analysis, but the response time of a fission couple is relatively slow in practice. The time lag originated from heat transfer process was demonstrated to be the dominating factor by theoretical simulations and experimental verification in this paper. The response of a fission couple as a function of the bead size and the thermocouple wires' sizes are simulated using ANSYS workbench. The decrease of wires' diameter results in the decrease of response time, and the increase of bead's diameter leads to a slight increase of response time. During a pulse heating transient in the fuel of Chinese Fast Burst Reactor II with a FWHM of 181 μs, the time lag originated from heat transfer process is about tens of microseconds for the peaks of the change rate of temperature, and is of the order of milliseconds to achieve 85% of the temperature rise for a typical fission couple with a Φ 1 mm fissile bead and two Φ 0.05 mm thermocouple wires. The results obtained provide foundation for the optimization of fission couples.

  2. Effect of the fissile bead's and thermocouple wires’ sizes on the response time of a fission couple

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, Wenfeng, E-mail: liang-wen-feng@163.com; Lu, Yi; Li, Meng

    The fission couple is proposed as a fast response miniature neutron detector in the measurement of time dependent energy depositions within the fissile material based on theoretical analysis, but the response time of a fission couple is relatively slow in practice. The time lag originated from heat transfer process was demonstrated to be the dominating factor by theoretical simulations and experimental verification in this paper. The response of a fission couple as a function of the bead size and the thermocouple wires’ sizes are simulated using ANSYS workbench. The decrease of wires’ diameter results in the decrease of response time,more » and the increase of bead's diameter leads to a slight increase of response time. During a pulse heating transient in the fuel of Chinese Fast Burst Reactor II with a FWHM of 181μs, the time lag originated from heat transfer process is about tens of microseconds for the peaks of the change rate of temperature, and is of the order of milliseconds to achieve 85% of the temperature rise for a typical fission couple with a Φ 1 mm fissile bead and two Φ 0.05 mm thermocouple wires. The results obtained provide foundation for the optimization of fission couples.« less

  3. Characterization of real-time computers

    NASA Technical Reports Server (NTRS)

    Shin, K. G.; Krishna, C. M.

    1984-01-01

    A real-time system consists of a computer controller and controlled processes. Despite the synergistic relationship between these two components, they have been traditionally designed and analyzed independently of and separately from each other; namely, computer controllers by computer scientists/engineers and controlled processes by control scientists. As a remedy for this problem, in this report real-time computers are characterized by performance measures based on computer controller response time that are: (1) congruent to the real-time applications, (2) able to offer an objective comparison of rival computer systems, and (3) experimentally measurable/determinable. These measures, unlike others, provide the real-time computer controller with a natural link to controlled processes. In order to demonstrate their utility and power, these measures are first determined for example controlled processes on the basis of control performance functionals. They are then used for two important real-time multiprocessor design applications - the number-power tradeoff and fault-masking and synchronization.

  4. The time course of corticospinal excitability during a simple reaction time task.

    PubMed

    Kennefick, Michael; Maslovat, Dana; Carlsen, Anthony N

    2014-01-01

    The production of movement in a simple reaction time task can be separated into two time periods: the foreperiod, which is thought to include preparatory processes, and the reaction time interval, which includes initiation processes. To better understand these processes, transcranial magnetic stimulation has been used to probe corticospinal excitability at various time points during response preparation and initiation. Previous research has shown that excitability decreases prior to the "go" stimulus and increases following the "go"; however these two time frames have been examined independently. The purpose of this study was to measure changes in CE during both the foreperiod and reaction time interval in a single experiment, relative to a resting baseline level. Participants performed a button press movement in a simple reaction time task and excitability was measured during rest, the foreperiod, and the reaction time interval. Results indicated that during the foreperiod, excitability levels quickly increased from baseline with the presentation of the warning signal, followed by a period of stable excitability leading up to the "go" signal, and finally a rapid increase in excitability during the reaction time interval. This excitability time course is consistent with neural activation models that describe movement preparation and response initiation.

  5. Noninvasive stress testing - Methodology for elimination of the phonocardiogram

    NASA Technical Reports Server (NTRS)

    Spodick, D. H.; Lance, V. Q.

    1976-01-01

    Measurement by systolic time intervals (STI) of cardiac responses requires extremely careful recording during actual stress test performance. Previous work indicated no significant changes in the pulse transmission time (PTT) during exercise and other challenges. Since external STI depend on the carotid pulse offset by the PTT as an aortic curve equivalent, stable PTT implies that timing of the carotid upstroke and the carotid incisura would respectively track the pre-ejection period and the aortic incisura. In ten subjects, STIs were recorded at supine rest, sitting, standing, during prompt and sustained squatting and during isometric and dynamic exercise. The results demonstrated the tracking of both points. Coefficients of correlation and of determination were uniformly high for all challenges except isometric handgrip (IHG). Since left ventricular ejection time is obtained directly from the pulse curve, with the exception of IHG, STI responses during stress testing can be measured without a phonocardiogram.

  6. Sleep hygiene behaviours: an application of the theory of planned behaviour and the investigation of perceived autonomy support, past behaviour and response inhibition.

    PubMed

    Kor, Kenny; Mullan, Barbara Ann

    2011-09-01

    This study investigated the sleep hygiene behaviour of university students within the framework of the Theory of Planned Behaviour (TPB [Ajzen, I. (1991). The theory of planned behavior. Organizational Behavior and Human Decision Processes, 50, 179-211.]), and examined the predictive validity of additional variables including perceived autonomy support, past behaviour and response inhibition. A total of 257 undergraduate students from an Australian university were administered two online questionnaires at two time points. At time 1, participants completed the TPB questionnaire and the Go/NoGo task as a measure of response inhibition. A week later at time 2, participants completed a questionnaire measuring the performance of sleep hygiene behaviours. Multiple and hierarchical regression analyses showed that the TPB model significantly predicted intention and behaviour. Although intention and perceived behavioural control were statistically significant in predicting behaviour, past behaviour and response inhibition accounted for more variance when added to the TPB model. Subjective norm was found to be the strongest predictor of intention implying the importance of normative influences in sleep hygiene behaviours. Response inhibition was the strongest predictor of behaviour, reinforcing the argument that the performance of health protective behaviours requires self-regulatory ability. Therefore, interventions should be targeted at enhancing self-regulatory capacity.

  7. Carbon Dioxide and Fruit Odor Transduction in Drosophila Olfactory Neurons. What Controls their Dynamic Properties?

    PubMed Central

    French, Andrew S.; Meisner, Shannon; Su, Chih-Ying; Torkkeli, Päivi H.

    2014-01-01

    We measured frequency response functions between odorants and action potentials in two types of neurons in Drosophila antennal basiconic sensilla. CO2 was used to stimulate ab1C neurons, and the fruit odor ethyl butyrate was used to stimulate ab3A neurons. We also measured frequency response functions for light-induced action potential responses from transgenic flies expressing H134R-channelrhodopsin-2 (ChR2) in the ab1C and ab3A neurons. Frequency response functions for all stimulation methods were well-fitted by a band-pass filter function with two time constants that determined the lower and upper frequency limits of the response. Low frequency time constants were the same in each type of neuron, independent of stimulus method, but varied between neuron types. High frequency time constants were significantly slower with ethyl butyrate stimulation than light or CO2 stimulation. In spite of these quantitative differences, there were strong similarities in the form and frequency ranges of all responses. Since light-activated ChR2 depolarizes neurons directly, rather than through a chemoreceptor mechanism, these data suggest that low frequency dynamic properties of Drosophila olfactory sensilla are dominated by neuron-specific ionic processes during action potential production. In contrast, high frequency dynamics are limited by processes associated with earlier steps in odor transduction, and CO2 is detected more rapidly than fruit odor. PMID:24466044

  8. Failing Tests: Commentary on "Adapting Educational Measurement to the Demands of Test-Based Accountability"

    ERIC Educational Resources Information Center

    Thissen, David

    2015-01-01

    In "Adapting Educational Measurement to the Demands of Test-Based Accountability" Koretz takes the time-honored engineering approach to educational measurement, identifying specific problems with current practice and proposing minimal modifications of the system to alleviate those problems. In response to that article, David Thissen…

  9. Calibration and Use of B Dot Probes for Electromagnetic Measuring

    DTIC Science & Technology

    1977-08-09

    response. E. Time Domain Reflectometry Measurements Pulse impedance measurements for the 1.75-in. diameter double-gap probe design were first performed...Far Field (Radiation) Patterns of a B Dot Probe 1. Anechoic Chamber The facility utilized for the probe patterns was the NASA 120-ft chamber at

  10. Fast-acting calorimeter measures heat output of plasma gun accelerator

    NASA Technical Reports Server (NTRS)

    Dethlefson, R.; Larson, A. V.; Liebing, L.

    1967-01-01

    Calorimeter measures the exhaust energy from a shot of a pulsed plasma gun accelerator. It has a fast response time and requires only one measurement to determine the total energy. It uses a long ribbon of copper foil wound around a glass frame to form a reentrant cavity.

  11. Assessment of humoral and cellular-mediated immune response in chickens treated with tilmicosin, florfenicol, or enrofloxacin at the time of Newcastle disease vaccination.

    PubMed

    Khalifeh, M S; Amawi, M M; Abu-Basha, E A; Yonis, I Bani

    2009-10-01

    The effect of tilmicosin, florfenicol, or enrofloxacin on humoral and cell-mediated immune response induced by Newcastle disease (ND) vaccination was evaluated in 20-wk-old specific-pathogen-free layer chickens. Humoral immunity was measured by detection of ND virus (NDV) antibody titer and anti-NDV IgG response using the hemagglutination inhibition (HI) test and ELISA, respectively, whereas cell-mediated immunity was evaluated by measurement of chicken interferon gamma (ChIFN-gamma) produced in splenocytes cell culture stimulated with concanavalin A, inactivated NDV antigen, or live attenuated La Sota strain using ELISA. Florfenicol hampered the ND antibody production measured by both HI and ELISA. Tilmicosin and enrofloxacin reduced the production of ND antibody in the first 3 wk after the last ND vaccination measured by HI test, which suggests that these antibiotics exert their effect mainly on the IgM isotype. The ND-vaccinated, but not treated group, showed an increase in ChIFN-gamma production after NDV antigen-specific stimulation above the nonstimulated cell culture, whereas this effect was masked in all the antibiotic-treated groups due to the stronger ChIFN-gamma production background value reported in the nonstimulated cell culture. In conclusion, our results showed, for the first time, that tilmicosin, florfenicol, or enrofloxacin reduced the humoral immune response and had beneficial effects on the cell-mediated immune response. In addition, we demonstrated that the combination of both inactivated and attenuated ND vaccine gave a strong immune response at both the humoral and cellular level.

  12. Predicting the response of a submillimeter bolometer to cosmic rays.

    PubMed

    Woodcraft, Adam L; Sudiwala, Rashmi V; Ade, Peter A R; Griffin, Matthew J; Wakui, Elley; Bhatia, Ravinder S; Lange, Andrew E; Bock, James J; Turner, Anthony D; Yun, Minhee H; Beeman, Jeffrey W

    2003-09-01

    Bolometers designed to detect submillimeter radiation also respond to cosmic, gamma, and x rays. Because detectors cannot be fully shielded from such energy sources, it is necessary to understand the effect of a photon or cosmic-ray particle being absorbed. The resulting signal (known as a glitch) can then be removed from raw data. We present measurements using an Americium-241 gamma radiation source to irradiate a prototype bolometer for the High Frequency Instrument in the Planck Surveyor satellite. Our measurements showed no variation in response depending on where the radiation was absorbed, demonstrating that the bolometer absorber and thermistor thermalize quickly. The bolometer has previously been fully characterized both electrically and optically. We find that using optically measured time constants underestimates the time taken for the detector to recover from a radiation absorption event. However, a full thermal model for the bolometer, with parameters taken from electrical and optical measurements, provides accurate time constants. Slight deviations from the model were seen at high energies; these can be accounted for by use of an extended model.

  13. Predicting the response of a submillimeter bolometer to cosmic rays

    NASA Astrophysics Data System (ADS)

    Woodcraft, Adam L.; Sudiwala, Rashmi V.; Ade, Peter A. R.; Griffin, Matthew J.; Wakui, Elley; Bhatia, Ravinder S.; Lange, Andrew E.; Bock, James J.; Turner, Anthony D.; Yun, Minhee H.; Beeman, Jeffrey W.

    2003-09-01

    Bolometers designed to detect submillimeter radiation also respond to cosmic, gamma, and x rays. Because detectors cannot be fully shielded from such energy sources, it is necessary to understand the effect of a photon or cosmic-ray particle being absorbed. The resulting signal (known as a glitch) can then be removed from raw data. We present measurements using an Americium-241 gamma radiation source to irradiate a prototype bolometer for the High Frequency Instrument in the Planck Surveyor satellite. Our measurements showed no variation in response depending on where the radiation was absorbed, demonstrating that the bolometer absorber and thermistor thermalize quickly. The bolometer has previously been fully characterized both electrically and optically. We find that using optically measured time constants underestimates the time taken for the detector to recover from a radiation absorption event. However, a full thermal model for the bolometer, with parameters taken from electrical and optical measurements, provides accurate time constants. Slight deviations from the model were seen at high energies; these can be accounted for by use of an extended model.

  14. 2D dosimetry in a proton beam with a scintillating GEM detector

    NASA Astrophysics Data System (ADS)

    Seravalli, E.; de Boer, M. R.; Geurink, F.; Huizenga, J.; Kreuger, R.; Schippers, J. M.; van Eijk, C. W. E.

    2009-06-01

    A two-dimensional position-sensitive dosimetry system based on a scintillating gas detector is being developed for pre-treatment verification of dose distributions in particle therapy. The dosimetry system consists of a chamber filled with an Ar/CF4 scintillating gas mixture, inside which two gas electron multiplier (GEM) structures are mounted (Seravalli et al 2008b Med. Phys. Biol. 53 4651-65). Photons emitted by the excited Ar/CF4 gas molecules during the gas multiplication in the GEM holes are detected by a mirror-lens-CCD camera system. The intensity distribution of the measured light spot is proportional to the 2D dose distribution. In this work, we report on the characterization of the scintillating GEM detector in terms of those properties that are of particular importance in relative dose measurements, e.g. response reproducibility, dose dependence, dose rate dependence, spatial and time response, field size dependence, response uniformity. The experiments were performed in a 150 MeV proton beam. We found that the detector response is very stable for measurements performed in succession (σ = 0.6%) and its response reproducibility over 2 days is about 5%. The detector response was found to be linear with the dose in the range 0.05-19 Gy. No dose rate effects were observed between 1 and 16 Gy min-1 at the shallow depth of a water phantom and 2 and 38 Gy min-1 at the Bragg peak depth. No field size effects were observed in the range 120-3850 mm2. A signal rise and fall time of 2 µs was recorded and a spatial response of <=1 mm was measured.

  15. Exposure to traffic pollution, acute inflammation and autonomic response in a panel of car commuters.

    PubMed

    Sarnat, Jeremy A; Golan, Rachel; Greenwald, Roby; Raysoni, Amit U; Kewada, Priya; Winquist, Andrea; Sarnat, Stefanie E; Dana Flanders, W; Mirabelli, Maria C; Zora, Jennifer E; Bergin, Michael H; Yip, Fuyuen

    2014-08-01

    Exposure to traffic pollution has been linked to numerous adverse health endpoints. Despite this, limited data examining traffic exposures during realistic commutes and acute response exists. We conducted the Atlanta Commuters Exposures (ACE-1) Study, an extensive panel-based exposure and health study, to measure chemically-resolved in-vehicle exposures and corresponding changes in acute oxidative stress, lipid peroxidation, pulmonary and systemic inflammation and autonomic response. We recruited 42 adults (21 with and 21 without asthma) to conduct two 2-h scripted highway commutes during morning rush hour in the metropolitan Atlanta area. A suite of in-vehicle particulate components were measured in the subjects' private vehicles. Biomarker measurements were conducted before, during, and immediately after the commutes and in 3 hourly intervals after commutes. At measurement time points within 3h after the commute, we observed mild to pronounced elevations relative to baseline in exhaled nitric oxide, C-reactive-protein, and exhaled malondialdehyde, indicative of pulmonary and systemic inflammation and oxidative stress initiation, as well as decreases relative to baseline levels in the time-domain heart-rate variability parameters, SDNN and rMSSD, indicative of autonomic dysfunction. We did not observe any detectable changes in lung function measurements (FEV1, FVC), the frequency-domain heart-rate variability parameter or other systemic biomarkers of vascular injury. Water soluble organic carbon was associated with changes in eNO at all post-commute time-points (p<0.0001). Our results point to measureable changes in pulmonary and autonomic biomarkers following a scripted 2-h highway commute. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Exposure to traffic pollution, acute inflammation and autonomic response in a panel of car commuters

    PubMed Central

    Sarnat, Jeremy A.; Golan, Rachel; Greenwald, Roby; Raysoni, Amit U.; Kewada, Priya; Winquist, Andrea; Sarnat, Stefanie E.; Flanders, W. Dana; Mirabelli, Maria C.; Zora, Jennifer E.; Bergin, Michael H.; Yip, Fuyuen

    2015-01-01

    Background Exposure to traffic pollution has been linked to numerous adverse health endpoints. Despite this, limited data examining traffic exposures during realistic commutes and acute response exists. Objectives: We conducted the Atlanta Commuters Exposures (ACE-1) Study, an extensive panel-based exposure and health study, to measure chemically-resolved in-vehicle exposures and corresponding changes in acute oxidative stress, lipid peroxidation, pulmonary and systemic inflammation and autonomic response. Methods We recruited 42 adults (21 with and 21 without asthma) to conduct two 2-h scripted highway commutes during morning rush hour in the metropolitan Atlanta area. A suite of in-vehicle particulate components were measured in the subjects’ private vehicles. Biomarker measurements were conducted before, during, and immediately after the commutes and in 3 hourly intervals after commutes. Results At measurement time points within 3 h after the commute, we observed mild to pronounced elevations relative to baseline in exhaled nitric oxide, C-reactive-protein, and exhaled malondialdehyde, indicative of pulmonary and systemic inflammation and oxidative stress initiation, as well as decreases relative to baseline levels in the time-domain heart-rate variability parameters, SDNN and rMSSD, indicative of autonomic dysfunction. We did not observe any detectable changes in lung function measurements (FEV1, FVC), the frequency-domain heart-rate variability parameter or other systemic biomarkers of vascular injury. Water soluble organic carbon was associated with changes in eNO at all post-commute time-points (p < 0.0001). Conclusions Our results point to measureable changes in pulmonary and autonomic biomarkers following a scripted 2-h highway commute. PMID:24906070

  17. Comparative Effects of Antihistamines on Aircrew Mission Effectiveness under Sustained Operations

    DTIC Science & Technology

    1992-06-01

    measures consist mainly of process measures. Process measures are measures of activities used to accomplish the mission and produce the final results...They include task completion times and response variability, and information processing rates as they relate to unique task assignment. Performance...contains process measures that assess the Individual contributions of hardware/software and human components to overall system performance. Measures

  18. Pulmonary tumor measurements from x-ray computed tomography in one, two, and three dimensions.

    PubMed

    Villemaire, Lauren; Owrangi, Amir M; Etemad-Rezai, Roya; Wilson, Laura; O'Riordan, Elaine; Keller, Harry; Driscoll, Brandon; Bauman, Glenn; Fenster, Aaron; Parraga, Grace

    2011-11-01

    We evaluated the accuracy and reproducibility of three-dimensional (3D) measurements of lung phantoms and patient tumors from x-ray computed tomography (CT) and compared these to one-dimensional (1D) and two-dimensional (2D) measurements. CT images of three spherical and three irregularly shaped tumor phantoms were evaluated by three observers who performed five repeated measurements. Additionally, three observers manually segmented 29 patient lung tumors five times each. Follow-up imaging was performed for 23 tumors and response criteria were compared. For a single subject, imaging was performed on nine occasions over 2 years to evaluate multidimensional tumor response. To evaluate measurement accuracy, we compared imaging measurements to ground truth using analysis of variance. For estimates of precision, intraobserver and interobserver coefficients of variation and intraclass correlations (ICC) were used. Linear regression and Pearson correlations were used to evaluate agreement and tumor response was descriptively compared. For spherical shaped phantoms, all measurements were highly accurate, but for irregularly shaped phantoms, only 3D measurements were in high agreement with ground truth measurements. All phantom and patient measurements showed high intra- and interobserver reproducibility (ICC >0.900). Over a 2-year period for a single patient, there was disagreement between tumor response classifications based on 3D measurements and those generated using 1D and 2D measurements. Tumor volume measurements were highly reproducible and accurate for irregular, spherical phantoms and patient tumors with nonuniform dimensions. Response classifications obtained from multidimensional measurements suggest that 3D measurements provide higher sensitivity to tumor response. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  19. Does the increasing placebo response impact outcomes of adult and pediatric ADHD clinical trials? Data from the US Food and Drug Administration 2000-2009.

    PubMed

    Khan, Arif; Fahl Mar, Kaysee; Brown, Walter A

    2017-11-01

    In a study of recent antidepressant clinical trial data, it was found placebo response had grown significantly over time and that contrary to expectations, trial outcome measures and success rate were not impacted. The aim of this paper was to evaluate if this trend of increasing placebo response and stable outcome measures could be seen in clinical trial data for Attention-Deficit Hyperactivity Disorder, a different psychiatric condition with susceptibility to placebo response. For this reason, we evaluated efficacy data reported in the FDA Medical and Statistical reviews for 10 ADHD medication programs (4917 patients, 17 trials, 29 treatment arms). Placebo and medication response were measured as percent symptom reduction and effect sizes and drug-placebo differences were calculated for each treatment arm and analyzed in relation to year of approval. We also investigated the potential role of age and medication class on trends and outcomes. Results showed a similar pattern to antidepressants wherein the placebo response is rising significantly over time (r = 0.636, p = 0.006) and effect size (r < 0.0001, p = 1.0), drug-placebo difference (r = -0.238, p = 0.214), and success rate (28/29 97%) have remained unaffected, likely due to a parallel, although not statistically significant increase in medication response (r = 0.326, p = 0.085). Age and medication class did not alter these observed time trends but pediatric trials and stimulants were found to have more robust treatment effects than adult trials and non-stimulants. The results of this study suggest that like antidepressants, the relationship between placebo response and the outcomes of ADHD clinical trials is weak at best. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. A model for incomplete longitudinal multivariate ordinal data.

    PubMed

    Liu, Li C

    2008-12-30

    In studies where multiple outcome items are repeatedly measured over time, missing data often occur. A longitudinal item response theory model is proposed for analysis of multivariate ordinal outcomes that are repeatedly measured. Under the MAR assumption, this model accommodates missing data at any level (missing item at any time point and/or missing time point). It allows for multiple random subject effects and the estimation of item discrimination parameters for the multiple outcome items. The covariates in the model can be at any level. Assuming either a probit or logistic response function, maximum marginal likelihood estimation is described utilizing multidimensional Gauss-Hermite quadrature for integration of the random effects. An iterative Fisher-scoring solution, which provides standard errors for all model parameters, is used. A data set from a longitudinal prevention study is used to motivate the application of the proposed model. In this study, multiple ordinal items of health behavior are repeatedly measured over time. Because of a planned missing design, subjects answered only two-third of all items at a given point. Copyright 2008 John Wiley & Sons, Ltd.

  1. INDIVIDUAL DIFFERENCES IN IMPULSIVE CHOICE AND TIMING IN RATS

    PubMed Central

    Galtress, Tiffany; Garcia, Ana; Kirkpatrick, Kimberly

    2012-01-01

    Individual differences in impulsive choice behavior have been linked to a variety of behavioral problems including substance abuse, smoking, gambling, and poor financial decision-making. Given the potential importance of individual differences in impulsive choice as a predictor of behavioral problems, the present study sought to measure the extent of individual differences in a normal sample of hooded Lister rats. Three experiments utilized variations of a delay discounting task to measure the degree of variation in impulsive choice behavior across individual rats. The individual differences accounted for 22–55% of the variance in choice behavior across the three experiments. In Experiments 2 and 3, the individual differences were still apparent when behavior was measured across multiple choice points. Large individual differences in the rate of responding, and modest individual differences in timing of responding were also observed during occasional peak trials. The individual differences in timing and rate, however, did not correlate consistently with individual differences in choice behavior. This suggests that a variety of factors may affect choice behavior, response rate, and response timing. PMID:22851792

  2. Emergency radiobioassay preparedness exercises through the NIST radiochemistry intercomparison program.

    PubMed

    Nour, Svetlana; LaRosa, Jerry; Inn, Kenneth G W

    2011-08-01

    The present challenge for the international emergency radiobioassay community is to analyze contaminated samples rapidly while maintaining high quality results. The National Institute of Standards and Technology (NIST) runs a radiobioassay measurement traceability testing program to evaluate the radioanalytical capabilities of participating laboratories. The NIST Radiochemistry Intercomparison Program (NRIP) started more than 10 years ago, and emergency performance testing was added to the program seven years ago. Radiobioassay turnaround times under the NRIP program for routine production and under emergency response scenarios are 60 d and 8 h, respectively. Because measurement accuracy and sample turnaround time are very critical in a radiological emergency, response laboratories' analytical systems are best evaluated and improved through traceable Performance Testing (PT) programs. The NRIP provides participant laboratories with metrology tools to evaluate their performance and to improve it. The program motivates the laboratories to optimize their methodologies and minimize the turnaround time of their results. Likewise, NIST has to make adjustments and periodical changes in the bioassay test samples in order to challenge the participating laboratories continually. With practice, radioanalytical measurements turnaround time can be reduced to 3-4 h.

  3. Unsaturated soil moisture drying and wetting diffusion coefficient measurements in the laboratory.

    DOT National Transportation Integrated Search

    2009-09-01

    ABSTRACTTransient moisture flow in an unsaturated soil in response to suction changes is controlled by the unsaturated moisture diffusion coefficient. The moisture diffusion coefficient can be determined by measuring suction profiles over time. The l...

  4. A FURTHER EVALUATION OF MICROCOULOMETRY FOR ATMOSPHERIC NITRIC ACID MONITORING

    EPA Science Inventory

    A coulometric instrument for measuring gaseous nitric acid is modified to improve response time characteristics and simplify operation. Possible interferences were investigated and found minimal. Comparison measurements of nitric acid by long path Fourier Transform infrared analy...

  5. Large Modal Survey Testing Using the Ibrahim Time Domain Identification Technique

    NASA Technical Reports Server (NTRS)

    Ibrahim, S. R.; Pappa, R. S.

    1985-01-01

    The ability of the ITD identification algorithm in identifying a complete set of structural modal parameters using a large number of free-response time histories simultaneously in one analysis, assuming a math model with a high number of degrees-of-freedom, has been studied. Identification results using simulated free responses of a uniform rectangular plate, with 225 measurement stations, and experimental responses from a ground vibration test of the Long Duration Exposure Facility (LDEF) Space Shuttle payload, with 142 measurement stations, are presented. As many as 300 degrees-of-freedom were allowed in analyzing these data. In general, the use of a significantly oversized math model in the identification process was found to maintain or increase identification accuracy and to identify modes of low response level that are not identified with smaller math model sizes. The concept of a Mode Shape Correlation Constant is introduced for use when more than one identification analysis of the same structure are conducted. This constant quantifies the degree of correlation between any two sets of complex mode shapes identified using different excitation conditions, different user-selectable algorithm constants, or overlapping sets of measurements.

  6. Large modal survey testing using the Ibrahim time domain /ITD/ identification technique

    NASA Technical Reports Server (NTRS)

    Ibrahim, S. R.; Pappa, R. S.

    1981-01-01

    The ability of the ITD identification algorithm in identifying a complete set of structural modal parameters using a large number of free-response time histories simultaneously in one analysis, assuming a math model with a high number of degrees-of-freedom, has been studied. Identification results using simulated free responses of a uniform rectangular plate, with 225 measurement stations, and experimental responses from a ground vibration test of the Long Duration Exposure Facility (LDEF) Space Shuttle payload, with 142 measurement stations, are presented. As many as 300 degrees-of-freedom were allowed in analyzing these data. In general, the use of a significantly oversized math model in the identification process was found to maintain or increase identification accuracy and to identify modes of low response level that are not identified with smaller math model sizes. The concept of a Mode Shape Correlation Constant is introduced for use when more than one identification analysis of the same structure are conducted. This constant quantifies the degree of correlation between any two sets of complex mode shapes identified using different excitation conditions, different user-selectable algorithm constants, or overlapping sets of measurements.

  7. The effects of self-induced mood states on behavior and physiological arousal.

    PubMed

    Matheny, K B; Blue, F R

    1977-10-01

    The effects of reading emotionally loaded statements on behavioral tasks and physiological measures were investigated. Statements were constructed to arouse elation, depression, or neutrality. Ss were both pre- and posttested on Writing Speed, Reaction Time, Decision Time, and Spontaneous Verbalizations. Base rates were obtained for heart rate and galvanic skin response. Elation Ss significantly outperformed both Neutral and Depression Ss on the Reaction Time task. Scores for Neutral Ss fell between those of Elation and Depression Ss on three of the four behavioral measures. No significant differneces were found on the physiological measures.

  8. Test-retest reliability of the multifocal photopic negative response.

    PubMed

    Van Alstine, Anthony W; Viswanathan, Suresh

    2017-02-01

    To assess the test-retest reliability of the multifocal photopic negative response (mfPhNR) of normal human subjects. Multifocal electroretinograms were recorded from one eye of 61 healthy adult subjects on two separate days using a Visual Evoked Response Imaging System software version 4.3 (EDI, San Mateo, California). The visual stimulus delivered on a 75-Hz monitor consisted of seven equal-sized hexagons each subtending 12° of visual angle. The m-step exponent was 9, and the m-sequence was slowed to include at least 30 blank frames after each flash. Only the first slice of the first-order kernel was analyzed. The mfPhNR amplitude was measured at a fixed time in the trough from baseline (BT) as well as at the same fixed time in the trough from the preceding b-wave peak (PT). Additionally, we also analyzed BT normalized either to PT (BT/PT) or to the b-wave amplitude (BT/b-wave). The relative reliability of test-retest differences for each test location was estimated by the Wilcoxon matched-pair signed-rank test and intraclass correlation coefficients (ICC). Absolute test-retest reliability was estimated by Bland-Altman analysis. The test-retest amplitude differences for neither of the two measurement techniques were statistically significant as determined by Wilcoxon matched-pair signed-rank test. PT measurements showed greater ICC values than BT amplitude measurements for all test locations. For each measurement technique, the ICC value of the macular response was greater than that of the surrounding locations. The mean test-retest difference was close to zero for both techniques at each of the test locations, and while the coefficient of reliability (COR-1.96 times the standard deviation of the test-retest difference) was comparable for the two techniques at each test location when expressed in nanovolts, the %COR (COR normalized to the mean test and retest amplitudes) was superior for PT than BT measurements. The ICC and COR were comparable for the BT/PT and BT/b-wave ratios and were better than the ICC and COR for BT but worse than PT. mfPhNR amplitude measured at a fixed time in the trough from the preceding b-wave peak (PT) shows greater test-retest reliability when compared to amplitude measurement from baseline (BT) or BT amplitude normalized to either the PT or b-wave amplitudes.

  9. A randomized, controlled trial of team-based competition to increase learner participation in quality-improvement education.

    PubMed

    Scales, Charles D; Moin, Tannaz; Fink, Arlene; Berry, Sandra H; Afsar-Manesh, Nasim; Mangione, Carol M; Kerfoot, B Price

    2016-04-01

    Several barriers challenge resident engagement in learning quality improvement (QI). We investigated whether the incorporation of team-based game mechanics into an evidence-based online learning platform could increase resident participation in a QI curriculum. Randomized, controlled trial. Tertiary-care medical center residency training programs. Resident physicians (n = 422) from nine training programs (anesthesia, emergency medicine, family medicine, internal medicine, ophthalmology, orthopedics, pediatrics, psychiatry and general surgery) randomly allocated to a team competition environment (n = 200) or the control group (n = 222). Specialty-based team assignment with leaderboards to foster competition, and alias assignment to de-identify individual participants. Participation in online learning, as measured by percentage of questions attempted (primary outcome) and additional secondary measures of engagement (i.e. response time). Changes in participation measures over time between groups were assessed with a repeated measures ANOVA framework. Residents in the intervention arm demonstrated greater participation than the control group. The percentage of questions attempted at least once was greater in the competition group (79% [SD ± 32] versus control, 68% [SD ± 37], P= 0.03). Median response time was faster in the competition group (P= 0.006). Differences in participation continued to increase over the duration of the intervention, as measured by average response time and cumulative percent of questions attempted (each P< 0.001). Team competition increases resident participation in an online course delivering QI content. Medical educators should consider game mechanics to optimize participation when designing learning experiences. Published by Oxford University Press in association with the International Society for Quality in Health Care 2016. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  10. Cognitive-behavioral therapy for children with functional abdominal pain and their parents decreases pain and other symptoms.

    PubMed

    Levy, Rona L; Langer, Shelby L; Walker, Lynn S; Romano, Joan M; Christie, Dennis L; Youssef, Nader; DuPen, Melissa M; Feld, Andrew D; Ballard, Sheri A; Welsh, Ericka M; Jeffery, Robert W; Young, Melissa; Coffey, Melissa J; Whitehead, William E

    2010-04-01

    Unexplained abdominal pain in children has been shown to be related to parental responses to symptoms. This randomized controlled trial tested the efficacy of an intervention designed to improve outcomes in idiopathic childhood abdominal pain by altering parental responses to pain and children's ways of coping and thinking about their symptoms. Two hundred children with persistent functional abdominal pain and their parents were randomly assigned to one of two conditions-a three-session intervention of cognitive-behavioral treatment targeting parents' responses to their children's pain complaints and children's coping responses, or a three-session educational intervention that controlled for time and attention. Parents and children were assessed at pretreatment, and 1 week, 3 months, and 6 months post-treatment. Outcome measures were child and parent reports of child pain levels, function, and adjustment. Process measures included parental protective responses to children's symptom reports and child coping methods. Children in the cognitive-behavioral condition showed greater baseline to follow-up decreases in pain and gastrointestinal symptom severity (as reported by parents) than children in the comparison condition (time x treatment interaction, P<0.01). Also, parents in the cognitive-behavioral condition reported greater decreases in solicitous responses to their child's symptoms compared with parents in the comparison condition (time x treatment interaction, P<0.0001). An intervention aimed at reducing protective parental responses and increasing child coping skills is effective in reducing children's pain and symptom levels compared with an educational control condition.

  11. Retinal blood flow during hyperoxia in humans revisited: concerted results using different measurement techniques.

    PubMed

    Kiss, Barbara; Polska, Elzbieta; Dorner, Guido; Polak, Kaija; Findl, Oliver; Mayrl, Gabriele Fuchsjäger; Eichler, Hans-Georg; Wolzt, Michael; Schmetterer, Leopold

    2002-07-01

    Retinal vasculature shows pronounced vasoconstriction in response to hyperoxia, which appears to be related to the constant oxygen demand of the retina. However, the exact amount of blood flow reduction and the exact time course of this phenomenon are still a matter of debate. We set out to investigate the retinal response to hyperoxia using innovative techniques for the assessment of retinal hemodynamics. In a total of 48 healthy volunteers we studied the effect of 100% O(2) breathing on retinal blood flow using two methods. Red blood cell movement in larger retinal veins was quantified with combined laser Doppler velocimetry and retinal vessel size measurement. Retinal white blood cell movement was quantified with the blue field entoptic technique. The time course of retinal vasoconstriction in response to hyperoxia was assessed by continuous vessel size determination using the Zeiss retinal vessel analyzer. The response to hyperoxia as measured with combined laser Doppler velocimetry and vessel size measurement was almost twice as high as that observed with the blue field technique. Vasoconstriction in response to 100% O(2) breathing occurred within the first 5 min and no counterregulatory or adaptive mechanisms were observed. Based on these results we hypothesize that hyperoxia-induced vasoconstriction differentially affects red and white blood cell movement in the human retina. This hypothesis is based on the complex interactions between red and white blood cells in microcirculation, which have been described in detail for other vascular beds.

  12. Is children's listening effort in background noise influenced by the speaker's voice quality?

    PubMed

    Sahlén, Birgitta; Haake, Magnus; von Lochow, Heike; Holm, Lucas; Kastberg, Tobias; Brännström, K Jonas; Lyberg-Åhlander, Viveka

    2018-07-01

    The present study aims at exploring the influence of voice quality on listening effort in children performing a language comprehension test with sentences of increasing difficulty. Listening effort is explored in relation to gender ( = cisgender). The study has a between-groups design. Ninety-three mainstreamed children aged 8;2 to 9;3 with typical language development participated. The children were randomly assigned to two groups (n = 46/47) with equal allocation of boys and girls and for the analysis to four groups depending of gender and voice condition. Working memory capacity and executive functions were tested in quiet. A digital version of a language comprehension test (the TROG-2) was used to measure the effect of voice quality on listening effort, measured as response time in a forced-choice paradigm. The groups listened to sentences through recordings of the same female voice, one group with a typical voice and one with a dysphonic voice, both in competing multi-talker babble noise. Response times were logged after a time buffer between the sentence-ending and indication of response. There was a significant increase in response times with increased task difficulty and response times between the two voice conditions differed significantly. The girls in the dysphonic condition were slower with increasing task difficulty. A dysphonic voice clearly adds to the noise burden and listening effort is greater in girls than in boys when the teacher speaks with dysphonic voice in a noisy background. These findings might mirror gender differences as for coping strategies in challenging contexts and have important implications for education.

  13. ChoiceKey: a real-time speech recognition program for psychology experiments with a small response set.

    PubMed

    Donkin, Christopher; Brown, Scott D; Heathcote, Andrew

    2009-02-01

    Psychological experiments often collect choice responses using buttonpresses. However, spoken responses are useful in many cases-for example, when working with special clinical populations, or when a paradigm demands vocalization, or when accurate response time measurements are desired. In these cases, spoken responses are typically collected using a voice key, which usually involves manual coding by experimenters in a tedious and error-prone manner. We describe ChoiceKey, an open-source speech recognition package for MATLAB. It can be optimized by training for small response sets and different speakers. We show ChoiceKey to be reliable with minimal training for most participants in experiments with two different responses. Problems presented by individual differences, and occasional atypical responses, are examined, and extensions to larger response sets are explored. The ChoiceKey source files and instructions may be downloaded as supplemental materials for this article from brm.psychonomic-journals.org/content/supplemental.

  14. THE LICK AGN MONITORING PROJECT: REVERBERATION MAPPING OF OPTICAL HYDROGEN AND HELIUM RECOMBINATION LINES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bentz, Misty C.; Walsh, Jonelle L.; Barth, Aaron J.

    2010-06-20

    We have recently completed a 64-night spectroscopic monitoring campaign at the Lick Observatory 3 m Shane telescope with the aim of measuring the masses of the black holes in 12 nearby (z < 0.05) Seyfert 1 galaxies with expected masses in the range {approx}10{sup 6}-10{sup 7} M{sub sun} and also the well-studied nearby active galactic nucleus (AGN) NGC 5548. Nine of the objects in the sample (including NGC 5548) showed optical variability of sufficient strength during the monitoring campaign to allow for a time lag to be measured between the continuum fluctuations and the response to these fluctuations in themore » broad H{beta} emission, which we have previously reported. We present here the light curves for the H{alpha}, H{gamma}, He II {lambda}4686, and He I {lambda}5876 emission lines and the time lags for the emission-line responses relative to changes in the continuum flux. Combining each emission-line time lag with the measured width of the line in the variable part of the spectrum, we determine a virial mass of the central supermassive black hole from several independent emission lines. We find that the masses are generally consistent within the uncertainties. The time-lag response as a function of velocity across the Balmer line profiles is examined for six of the AGNs. We find similar responses across all three Balmer lines for Arp 151, which shows a strongly asymmetric profile, and for SBS 1116+583A and NGC 6814, which show a symmetric response about zero velocity. For the other three AGNs, the data quality is somewhat lower and the velocity-resolved time-lag response is less clear. Finally, we compare several trends seen in the data set against the predictions from photoionization calculations as presented by Korista and Goad. We confirm several of their predictions, including an increase in responsivity and a decrease in the mean time lag as the excitation and ionization level for the species increases. Specifically, we find the time lags of the optical recombination lines to have weighted mean ratios of {tau}(H{alpha}):{tau}(H{beta}):{tau}(H{gamma}):{tau}(He I):{tau}(He II) = 1.54:1.00:0.61:0.36:0.25. Further confirmation of photoionization predictions for broad-line gas behavior will require additional monitoring programs for these AGNs while they are in different luminosity states.« less

  15. Acquisition of peak responding: what is learned?

    PubMed

    Balci, Fuat; Gallistel, Charles R; Allen, Brian D; Frank, Krystal M; Gibson, Jacqueline M; Brunner, Daniela

    2009-01-01

    We investigated how the common measures of timing performance behaved in the course of training on the peak procedure in C3H mice. Following fixed interval (FI) pre-training, mice received 16 days of training in the peak procedure. The peak time and spread were derived from the average response rates while the start and stop times and their relative variability were derived from a single-trial analysis. Temporal precision (response spread) appeared to improve in the course of training. This apparent improvement in precision was, however, an averaging artifact; it was mediated by the staggered appearance of timed stops, rather than by the delayed occurrence of start times. Trial-by-trial analysis of the stop times for individual subjects revealed that stops appeared abruptly after three to five sessions and their timing did not change as training was prolonged. Start times and the precision of start and stop times were generally stable throughout training. Our results show that subjects do not gradually learn to time their start or stop of responding. Instead, they learn the duration of the FI, with robust temporal control over the start of the response; the control over the stop of response appears abruptly later.

  16. Acquisition of peak responding: What is learned?

    PubMed Central

    Balci, Fuat; Gallistel, Charles R.; Allen, Brian D.; Frank, Krystal M.; Gibson, Jacqueline M.; Brunner, Daniela

    2009-01-01

    We investigated how the common measures of timing performance behaved in the course of training on the peak procedure in C3H mice. Following fixed interval (FI) pre-training, mice received 16 days of training in the peak procedure. The peak time and spread were derived from the average response rates while the start and stop times and their relative variability were derived from a single-trial analysis. Temporal precision (response spread) appeared to improve in the course of training. This apparent improvement in precision was, however, an averaging artifact; it was mediated by the staggered appearance of timed stops, rather than by the delayed occurrence of start times. Trial-by-trial analysis of the stop times for individual subjects revealed that stops appeared abruptly after three to five sessions and their timing did not change as training was prolonged. Start times and the precision of start and stop times were generally stable throughout training. Our results show that subjects do not gradually learn to time their start or stop of responding. Instead, they learn the duration of the FI, with robust temporal control over the start of the response; the control over the stop of response appears abruptly later. PMID:18950695

  17. On the timing performance of thin planar silicon sensors

    NASA Astrophysics Data System (ADS)

    Akchurin, N.; Ciriolo, V.; Currás, E.; Damgov, J.; Fernández, M.; Gallrapp, C.; Gray, L.; Junkes, A.; Mannelli, M.; Martin Kwok, K. H.; Meridiani, P.; Moll, M.; Nourbakhsh, S.; Pigazzini, S.; Scharf, C.; Silva, P.; Steinbrueck, G.; de Fatis, T. Tabarelli; Vila, I.

    2017-07-01

    We report on the signal timing capabilities of thin silicon sensors when traversed by multiple simultaneous minimum ionizing particles (MIP). Three different planar sensors, with depletion thicknesses 133, 211, and 285 μm, have been exposed to high energy muons and electrons at CERN. We describe signal shape and timing resolution measurements as well as the response of these devices as a function of the multiplicity of MIPs. We compare these measurements to simulations where possible. We achieve better than 20 ps timing resolution for signals larger than a few tens of MIPs.

  18. Comparison of response times of a mobile-web EHRs system using PHP and JSP languages.

    PubMed

    De la Torre-Díez, Isabel; Antón-Rodríguez, Míriam; Díaz-Pernas, Francisco Javier; Perozo-Rondón, Freddy José

    2012-12-01

    Performance evaluation is highly important in the Electronic Health Records (EHRs) system implementation. Response time's measurement can be considered as one manner to make that evaluation. In the e-health field, after the creation of EHRs available through different platforms such as Web and/or mobile, a performance evaluation is necessary. The operation of the system in the right way is essential. In this paper, a comparison of the response times for the MEHRmobile system is presented. The first version uses PHP language with a MySQL database and the second one employs JSP with an eXist database. Both versions have got the same functionalities. In addition to the technological aspects, a significant difference is the way the information is stored. The main goal of this paper is choosing the version which offers better response times. We have created a new benchmark to calculate the response times. Better results have been obtained for the PHP version. Nowadays, this version is being used for specialists from Fundación Intras, Spain.

  19. Appetitive and aversive motivation in dysphoria: A time-domain and time-frequency study of response inhibition.

    PubMed

    Messerotti Benvenuti, Simone; Buodo, Giulia; Palomba, Daniela

    2017-04-01

    The study of emotional response inhibition could provide novel insight into dysphoria-related deficits in appetitive and aversive motivational systems. Therefore, dysphoric (N=21) and nondysphoric (N=21) participants completed an emotional Go/Nogo paradigm, including the presentation of pleasant, neutral and unpleasant pictures. Behavioral measures [reaction times (RTs), accuracy to Go and Nogo stimuli] and neural correlates (Go/Nogo-N2 and Go/Nogo-P3) of response inhibition were compared between the two groups. Time-frequency analysis was also used as a novel approach to disentangle the multiple processes underlying time-domain ERP data. A reduced Go/Nogo effect for P3 and oscillatory delta activity was found in response to pleasant and neutral, but not unpleasant, stimuli in dysphoric relative to nondysphoric individuals. These findings showed that dysphoric individuals need a reduced and/or less effortful response inhibition to pleasant stimuli, suggesting that dysphoria is characterized by under-engagement of appetitive rather than over-engagement of aversive motivational system. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. High Resolution Flash Flood Forecasting Using a Wireless Sensor Network in the Dallas-Fort Worth Metroplex

    NASA Astrophysics Data System (ADS)

    Bartos, M. D.; Kerkez, B.; Noh, S.; Seo, D. J.

    2017-12-01

    In this study, we develop and evaluate a high resolution urban flash flood monitoring system using a wireless sensor network (WSN), a real-time rainfall-runoff model, and spatially-explicit radar rainfall predictions. Flooding is the leading cause of natural disaster fatalities in the US, with flash flooding in particular responsible for a majority of flooding deaths. While many riverine flood models have been operationalized into early warning systems, there is currently no model that is capable of reliably predicting flash floods in urban areas. Urban flash floods are particularly difficult to model due to a lack of rainfall and runoff data at appropriate scales. To address this problem, we develop a wide-area flood-monitoring wireless sensor network for the Dallas-Fort Worth metroplex, and use this network to characterize rainfall-runoff response over multiple heterogeneous catchments. First, we deploy a network of 22 wireless sensor nodes to collect real-time stream stage measurements over catchments ranging from 2-80 km2 in size. Next, we characterize the rainfall-runoff response of each catchment by combining stream stage data with gage and radar-based precipitation measurements. Finally, we demonstrate the potential for real-time flash flood prediction by joining the derived rainfall-runoff models with real-time radar rainfall predictions. We find that runoff response is highly heterogeneous among catchments, with large variabilities in runoff response detected even among nearby gages. However, when spatially-explicit rainfall fields are included, spatial variability in runoff response is largely captured. This result highlights the importance of increased spatial coverage for flash flood prediction.

  1. Standardization of UV LED measurements

    NASA Astrophysics Data System (ADS)

    Eppeldauer, G. P.; Larason, T. C.; Yoon, H. W.

    2015-09-01

    Traditionally used source spectral-distribution or detector spectral-response based standards cannot be applied for accurate UV LED measurements. Since the CIE standardized rectangular-shape spectral response function for UV measurements cannot be realized with small spectral mismatch when using filtered detectors, the UV measurement errors can be several times ten percent or larger. The UV LEDs produce broadband radiation and both their peaks or spectral bandwidths can change significantly. The detectors used for the measurement of these LEDs also have different spectral bandwidths. In the discussed example, where LEDs with 365 nm peak are applied for fluorescent crack-recognition using liquid penetrant (non-destructive) inspection, the broadband radiometric LED (signal) measurement procedure is standardized. A UV LED irradiance-source was calibrated against an FEL lamp standard to determine its spectral irradiance. The spectral irradiance responsivity of a reference UV meter was also calibrated. The output signal of the reference UV meter was calculated from the spectral irradiance of the UV source and the spectral irradiance responsivity of the reference UV meter. From the output signal, both the integrated irradiance (in the reference plane of the reference meter) and the integrated responsivity of the reference meter were determined. Test UV meters calibrated for integrated responsivity against the reference UV meter, can be used to determine the integrated irradiance from a field UV source. The obtained 5 % (k=2) measurement uncertainty can be decreased when meters with spectral response close to a constant value are selected.

  2. Transient response to three-phase faults on a wind turbine generator. Ph.D. Thesis - Toledo Univ.

    NASA Technical Reports Server (NTRS)

    Gilbert, L. J.

    1978-01-01

    In order to obtain a measure of its responses to short circuits a large horizontal axis wind turbine generator was modeled and its performance was simulated on a digital computer. Simulation of short circuit faults on the synchronous alternator of a wind turbine generator, without resort to the classical assumptions generally made for that analysis, indicates that maximum clearing times for the system tied to an infinite bus are longer than the typical clearing times for equivalent capacity conventional machines. Also, maximum clearing times are independent of tower shadow and wind shear. Variation of circuit conditions produce the modifications in the transient response predicted by analysis.

  3. Binocular summation and peripheral visual response time

    NASA Technical Reports Server (NTRS)

    Gilliland, K.; Haines, R. F.

    1975-01-01

    Six males were administered a peripheral visual response time test to the onset of brief small stimuli imaged in 10-deg arc separation intervals across the dark adapted horizontal retinal meridian under both binocular and monocular viewing conditions. This was done in an attempt to verify the existence of peripheral binocular summation using a response time measure. The results indicated that from 50-deg arc right to 50-deg arc left of the line of sight binocular summation is a reasonable explanation for the significantly faster binocular data. The stimulus position by viewing eye interaction was also significant. A discussion of these and other analyses is presented along with a review of related literature.

  4. Neural Reactivity to Angry Faces Predicts Treatment Response in Pediatric Anxiety.

    PubMed

    Bunford, Nora; Kujawa, Autumn; Fitzgerald, Kate D; Swain, James E; Hanna, Gregory L; Koschmann, Elizabeth; Simpson, David; Connolly, Sucheta; Monk, Christopher S; Phan, K Luan

    2017-02-01

    Although cognitive-behavioral psychotherapy (CBT) and pharmacotherapy are evidence-based treatments for pediatric anxiety, many youth with anxiety disorders fail to respond to these treatments. Given limitations of clinical measures in predicting treatment response, identifying neural predictors is timely. In this study, 35 anxious youth (ages 7-19 years) completed an emotional face-matching task during which the late positive potential (LPP), an event-related potential (ERP) component that indexes sustained attention towards emotional stimuli, was measured. Following the ERP measurement, youth received CBT or selective serotonin reuptake inhibitor (SSRI) treatment, and the LPP was examined as a predictor of treatment response. Findings indicated that, accounting for pre-treatment anxiety severity, neural reactivity to emotional faces predicted anxiety severity post- CBT and SSRI treatment such that enhanced electrocortical response to angry faces was associated with better treatment response. An enhanced LPP to angry faces may predict treatment response insofar as it may reflect greater emotion dysregulation or less avoidance and/or enhanced engagement with environmental stimuli in general, including with treatment.

  5. Technical Note: Response time evolution of XR-QA2 GafChromic™ film models.

    PubMed

    Aldelaijan, Saad; Tomic, Nada; Papaconstadopoulos, Pavlos; Schneider, James; Seuntjens, Jan; Shih, Shelley; Lewis, David; Devic, Slobodan

    2018-01-01

    To evaluate the response of the newest XR-QA2 GafChromic™ film model in terms of postexposure signal growth and energy response in comparison with the older XR-QA (Version 2) model. Pieces of film were irradiated to air kerma in air values up to 12 cGy with several beam qualities (5.3-8.25 mm Al) commonly used for CT scanning. Film response was scored in terms of net reflectance from scanned film images at various points in time postirradiation ranging from 1 to 7 days and 5 months postexposure. To reconstruct the measurement signal changes with postirradiation delay, we irradiated one film piece and then scanned it at different point times starting from 2" min and up to 3 days postexposure. For all beam qualities and dose range investigated, it appears that the XR-QA2 film signal completely saturated after 15 h. Compared to 15 h postirradiation scanning time, the observed variation in net reflectance were 3%, 2%, and 1% for film scanned 2" min, 20 min, and 3 h after exposure, respectively, which is well within the measurement uncertainty of the XR-QA2 based reference radiochromic film dosimetry system. A comparison between the XR-QA (Version 2) and the XR-QA2 film response after several months (relative to their responses after 24 h) show differences in up to 8% and 1% for each film model respectively. The replacement of cesium bromide in the older XR-QA (Version 2) film model with bismuth oxide in the newer XR-QA2 film, while keeping the same single sensitive layer structure, lead to a significantly more stable postexposure response. © 2017 American Association of Physicists in Medicine.

  6. Cognitive Resilience and Psychological Responses across a Collegiate Rowing Season.

    PubMed

    Shields, Morgan R; Brooks, M Alison; Koltyn, Kelli F; Kim, Jee-Seon; Cook, Dane B

    2017-11-01

    Student-athletes face numerous challenges across their competitive season. Although mood states have been previously studied, little is known about adaptations in other psychological responses, specifically cognition. The purpose of this study was to characterize cognitive function, mood, sleep, and stress responses at select time points of a season in collegiate rowers. It was hypothesized that during baseline, typical training, and recovery, athletes would show positive mental health profiles, in contrast to decreases in cognition with increases in negative mood and measurements of stress during peak training. Male and female Division I rowers (N = 43) and healthy controls (N = 23) were enrolled and assessed at baseline, typical training, peak training, and recovery. At each time point, measures of cognitive performance (Stroop color-naming task), academic and exercise load, perceived cognitive deficits, mood states, sleep, and stress (via self-report and salivary cortisol) were recorded. Repeated-measures ANOVA revealed significant group-time interactions for perceived exercise load, cognitive deficits, mood states, and perceived stress (P < 0.05). For athletes during peak training, the perception of cognitive deficits was positively correlated with mood disturbance (r = 0.54, P < 0.05) and perceived stress (r = 0.55, P < 0.05) and negatively correlated with response accuracy during incongruent Stroop trials (r = -0.38, P < 0.05). Cognitive performance did not change over the course of the season for either group. Cortisol and sleepiness changed over the course of the season but no significant interactions were observed. These results demonstrate that various psychological responses change over the course of a season, but they also highlight adaptation indicative of cognitive resilience among student-athletes.

  7. Characterization of charge trapping phenomena at III-N/dielectric interfaces

    NASA Astrophysics Data System (ADS)

    Stradiotto, Roberta; Pobegen, Gregor; Ostermaier, Clemens; Grasser, Tibor

    2016-11-01

    Charge trapping related phenomena are among the most serious reliability issues in GaN/AlGaN MIS-HEMTs technology. Today, many research efforts are undertaken to investigate and identify the defects responsible for device degradation. This work focuses on the trap sites located close to the interface with the dielectric, which are responsible for large voltage drifts in on-state conditions. We study the response of GaN/AlGaN/SiN systems to small and large signal excitation. Measurements performed with a lock-in amplifier enable us to deeply understand the dynamic behavior because of the improved time resolution and the versatility of the instrument. We investigate the frequency dispersion and the hysteresis of these devices and conclude that direct analysis of impedance characteristics is not sufficient to extract information about the interface trap response. We propose a methodology to study trapping phenomena based on transient measurement analysis, describing the approximations made and their effect on the accuracy of the result. Results on MIS test structures confirm the existence of a broad distribution of trap states. Capture time constants are found to be uniformly distributed in the experimental time window between 50 μs and 100 s.

  8. Monitoring the Single-Cell Stress Response of the Diatom Thalassiosira pseudonana by Quantitative Real-Time Reverse Transcription-PCR

    PubMed Central

    Shi, Xu; Gao, Weimin; Chao, Shih-hui

    2013-01-01

    Directly monitoring the stress response of microbes to their environments could be one way to inspect the health of microorganisms themselves, as well as the environments in which the microorganisms live. The ultimate resolution for such an endeavor could be down to a single-cell level. In this study, using the diatom Thalassiosira pseudonana as a model species, we aimed to measure gene expression responses of this organism to various stresses at a single-cell level. We developed a single-cell quantitative real-time reverse transcription-PCR (RT-qPCR) protocol and applied it to determine the expression levels of multiple selected genes under nitrogen, phosphate, and iron depletion stress conditions. The results, for the first time, provided a quantitative measurement of gene expression at single-cell levels in T. pseudonana and demonstrated that significant gene expression heterogeneity was present within the cell population. In addition, different expression patterns between single-cell- and bulk-cell-based analyses were also observed for all genes assayed in this study, suggesting that cell response heterogeneity needs to be taken into consideration in order to obtain accurate information that indicates the environmental stress condition. PMID:23315741

  9. Monitoring the single-cell stress response of the diatom Thalassiosira pseudonana by quantitative real-time reverse transcription-PCR.

    PubMed

    Shi, Xu; Gao, Weimin; Chao, Shih-hui; Zhang, Weiwen; Meldrum, Deirdre R

    2013-03-01

    Directly monitoring the stress response of microbes to their environments could be one way to inspect the health of microorganisms themselves, as well as the environments in which the microorganisms live. The ultimate resolution for such an endeavor could be down to a single-cell level. In this study, using the diatom Thalassiosira pseudonana as a model species, we aimed to measure gene expression responses of this organism to various stresses at a single-cell level. We developed a single-cell quantitative real-time reverse transcription-PCR (RT-qPCR) protocol and applied it to determine the expression levels of multiple selected genes under nitrogen, phosphate, and iron depletion stress conditions. The results, for the first time, provided a quantitative measurement of gene expression at single-cell levels in T. pseudonana and demonstrated that significant gene expression heterogeneity was present within the cell population. In addition, different expression patterns between single-cell- and bulk-cell-based analyses were also observed for all genes assayed in this study, suggesting that cell response heterogeneity needs to be taken into consideration in order to obtain accurate information that indicates the environmental stress condition.

  10. Wavenumber-frequency Spectra of Pressure Fluctuations Measured via Fast Response Pressure Sensitive Paint

    NASA Technical Reports Server (NTRS)

    Panda, J.; Roozeboom, N. H.; Ross, J. C.

    2016-01-01

    The recent advancement in fast-response Pressure-Sensitive Paint (PSP) allows time-resolved measurements of unsteady pressure fluctuations from a dense grid of spatial points on a wind tunnel model. This capability allows for direct calculations of the wavenumber-frequency (k-?) spectrum of pressure fluctuations. Such data, useful for the vibro-acoustics analysis of aerospace vehicles, are difficult to obtain otherwise. For the present work, time histories of pressure fluctuations on a flat plate subjected to vortex shedding from a rectangular bluff-body were measured using PSP. The light intensity levels in the photographic images were then converted to instantaneous pressure histories by applying calibration constants, which were calculated from a few dynamic pressure sensors placed at selective points on the plate. Fourier transform of the time-histories from a large number of spatial points provided k-? spectra for pressure fluctuations. The data provides first glimpse into the possibility of creating detailed forcing functions for vibro-acoustics analysis of aerospace vehicles, albeit for a limited frequency range.

  11. Acoustic emission monitoring system

    DOEpatents

    Romrell, Delwin M.

    1977-07-05

    Methods and apparatus for identifying the source location of acoustic emissions generated within an acoustically conductive medium. A plurality of acoustic receivers are communicably coupled to the surface of the medium at a corresponding number of spaced locations. The differences in the reception time of the respective sensors in response to a given acoustic event are measured among various sensor combinations prescribed by the monitoring mode employed. Acoustic reception response encountered subsequent to the reception by a predetermined number of the prescribed sensor combinations are inhibited from being communicated to the processing circuitry, while the time measurements obtained from the prescribed sensor combinations are translated into a position measurement representative of the location on the surface most proximate the source of the emission. The apparatus is programmable to function in six separate and five distinct operating modes employing either two, three or four sensory locations. In its preferred arrangement the apparatus of this invention will re-initiate a monitoring interval if the predetermined number of sensors do not respond to a particular emission within a given time period.

  12. Millisecond precision psychological research in a world of commodity computers: new hardware, new problems?

    PubMed

    Plant, Richard R; Turner, Garry

    2009-08-01

    Since the publication of Plant, Hammond, and Turner (2004), which highlighted a pressing need for researchers to pay more attention to sources of error in computer-based experiments, the landscape has undoubtedly changed, but not necessarily for the better. Readily available hardware has improved in terms of raw speed; multi core processors abound; graphics cards now have hundreds of megabytes of RAM; main memory is measured in gigabytes; drive space is measured in terabytes; ever larger thin film transistor displays capable of single-digit response times, together with newer Digital Light Processing multimedia projectors, enable much greater graphic complexity; and new 64-bit operating systems, such as Microsoft Vista, are now commonplace. However, have millisecond-accurate presentation and response timing improved, and will they ever be available in commodity computers and peripherals? In the present article, we used a Black Box ToolKit to measure the variability in timing characteristics of hardware used commonly in psychological research.

  13. Call progress time measurement in IP telephony

    NASA Astrophysics Data System (ADS)

    Khasnabish, Bhumip

    1999-11-01

    Usually a voice call is established through multiple stages in IP telephony. In the first stage, a phone number is dialed to reach a near-end or call-originating IP-telephony gateway. The next stages involve user identification through delivering an m-digit user-id to the authentication and/or billing server, and then user authentication by using an n- digit PIN. After that, the caller is allowed (last stage dial tone is provided) to dial a destination phone number provided that authentication is successful. In this paper, we present a very flexible method for measuring call progress time in IP telephony. The proposed technique can be used to measure the system response time at every stage. It is flexible, so that it can be easily modified to include new `tone' or a set of tones, or `voice begin' can be used in every stage to detect the system's response. The proposed method has been implemented using scripts written in Hammer visual basic language for testing with a few commercially available IP telephony gateways.

  14. Microeconomics. Harnessing naturally occurring data to measure the response of spending to income.

    PubMed

    Gelman, Michael; Kariv, Shachar; Shapiro, Matthew D; Silverman, Dan; Tadelis, Steven

    2014-07-11

    This paper presents a new data infrastructure for measuring economic activity. The infrastructure records transactions and account balances, yielding measurements with scope and accuracy that have little precedent in economics. The data are drawn from a diverse population that overrepresents males and younger adults but contains large numbers of underrepresented groups. The data infrastructure permits evaluation of a benchmark theory in economics that predicts that individuals should use a combination of cash management, saving, and borrowing to make the timing of income irrelevant for the timing of spending. As in previous studies and in contrast to the predictions of the theory, there is a response of spending to the arrival of anticipated income. The data also show, however, that this apparent excess sensitivity of spending results largely from the coincident timing of regular income and regular spending. The remaining excess sensitivity is concentrated among individuals with less liquidity. Copyright © 2014, American Association for the Advancement of Science.

  15. Fusions of Breast Carcinoma and Dendritic Cells as a Vaccine for the Treatment of Metatastic Breast Cancer

    DTIC Science & Technology

    2012-07-01

    well tolerated, induced immunologic responses in a majority of patients, and resulted in disease regression in subset. We postulated that...immunity are being obtained at serial time points following vaccination. Time to disease progression and RECIST measurable disease response will be...progressive disease , and one elected to pursue standard of care therapy only. Three participants, BV01, BV04 and BV06, completed vaccinations. Two patients

  16. Sustained attention to response task (SART) shows impaired vigilance in a spectrum of disorders of excessive daytime sleepiness.

    PubMed

    Van Schie, Mojca K M; Thijs, Roland D; Fronczek, Rolf; Middelkoop, Huub A M; Lammers, Gert Jan; Van Dijk, J Gert

    2012-08-01

    The sustained attention to response task comprises withholding key presses to one in nine of 225 target stimuli; it proved to be a sensitive measure of vigilance in a small group of narcoleptics. We studied sustained attention to response task results in 96 patients from a tertiary narcolepsy referral centre. Diagnoses according to ICSD-2 criteria were narcolepsy with (n=42) and without cataplexy (n=5), idiopathic hypersomnia without long sleep time (n=37), and obstructive sleep apnoea syndrome (n=12). The sustained attention to response task was administered prior to each of five multiple sleep latency test sessions. Analysis concerned error rates, mean reaction time, reaction time variability and post-error slowing, as well as the correlation of sustained attention to response task results with mean latency of the multiple sleep latency test and possible time of day influences. Median sustained attention to response task error scores ranged from 8.4 to 11.1, and mean reaction times from 332 to 366ms. Sustained attention to response task error score and mean reaction time did not differ significantly between patient groups. Sustained attention to response task error score did not correlate with multiple sleep latency test sleep latency. Reaction time was more variable as the error score was higher. Sustained attention to response task error score was highest for the first session. We conclude that a high sustained attention to response task error rate reflects vigilance impairment in excessive daytime sleepiness irrespective of its cause. The sustained attention to response task and the multiple sleep latency test reflect different aspects of sleep/wakefulness and are complementary. © 2011 European Sleep Research Society.

  17. Belief bias during reasoning among religious believers and skeptics.

    PubMed

    Pennycook, Gordon; Cheyne, James Allan; Koehler, Derek J; Fugelsang, Jonathan A

    2013-08-01

    We provide evidence that religious skeptics, as compared to believers, are both more reflective and effective in logical reasoning tasks. While recent studies have reported a negative association between an analytic cognitive style and religiosity, they focused exclusively on accuracy, making it difficult to specify potential underlying cognitive mechanisms. The present study extends the previous research by assessing both performance and response times on quintessential logical reasoning problems (syllogisms). Those reporting more religious skepticism made fewer reasoning errors than did believers. This finding remained significant after controlling for general cognitive ability, time spent on the problems, and various demographic variables. Crucial for the purpose of exploring underlying mechanisms, response times indicated that skeptics also spent more time reasoning than did believers. This novel finding suggests a possible role of response slowing during analytic problem solving as a component of cognitive style that promotes overriding intuitive first impressions. Implications for using additional processing measures, such as response time, to investigate individual differences in cognitive style are discussed.

  18. Slower is not always better: Response-time evidence clarifies the limited role of miserly information processing in the Cognitive Reflection Test

    PubMed Central

    Pitchford, Melanie; Ball, Linden J.; Hunt, Thomas E.; Steel, Richard

    2017-01-01

    We report a study examining the role of ‘cognitive miserliness’ as a determinant of poor performance on the standard three-item Cognitive Reflection Test (CRT). The cognitive miserliness hypothesis proposes that people often respond incorrectly on CRT items because of an unwillingness to go beyond default, heuristic processing and invest time and effort in analytic, reflective processing. Our analysis (N = 391) focused on people’s response times to CRT items to determine whether predicted associations are evident between miserly thinking and the generation of incorrect, intuitive answers. Evidence indicated only a weak correlation between CRT response times and accuracy. Item-level analyses also failed to demonstrate predicted response-time differences between correct analytic and incorrect intuitive answers for two of the three CRT items. We question whether participants who give incorrect intuitive answers on the CRT can legitimately be termed cognitive misers and whether the three CRT items measure the same general construct. PMID:29099840

  19. Preliminary Observations of Ionospheric Response to an Auroral Driver from the MICA (Magnetosphere-Ionosphere Coupling in the Alfvén Resonator) Sounding Rocket Campaign

    NASA Astrophysics Data System (ADS)

    Fernandes, P. A.; Lynch, K. A.; Hysell, D. L.; Powell, S.; Miceli, R.; Hampton, D. L.; Ahrns, J.; Lessard, M.; Cohen, I. J.; Moen, J. I.; Bekkeng, T.

    2012-12-01

    The nightside sounding rocket MICA (Magnetosphere-Ionosphere Coupling in the Alfvén Resonator) launched from Poker Flat, AK, on February 19, 2012, and reached an apogee of 325km. MICA was launched into several discrete, localized arcs in the wake of a westward traveling surge. The MICA instrumentation included both in situ and ground based instruments, and was designed to measure the response of the ionosphere to an auroral driver. More specifically, the science goal was to measure response of the ionosphere to a feedback instability in the ionospheric Alfvén resonator. The MICA payload included in situ particle, electric and magnetic field, and GPS instruments. The ground-based array consisted of a multitude of imagers, coherent and incoherent scatter radars, and a Fabry-Perot interferometer. We present observational characteristics of the response of the ionospheric plasma to the auroral drivers inferred from inverting camera data. We compare the measured precipitating electron population to inversions of camera images, which use a transport model to infer a 2D map of the precipitation. Comparisons show that as the payload passes through what appears to be an Alfvénic auroral arc, the in situ electron instrument shows dispersions indicative of Alfvénic activity. We then introduce measurements of the thermal ion distribution, to examine how the auroral arcs drive a response in the ionosphere. The thermal ion data show that the payload potential strengthens as the payload passes through the arc. When including electron density, temperature, and electric field data, we observe times in which the ionospheric environment changes as the precipitation changes, and times during which there is no measured response by the ionosphere. Future work will compare how the ion bulk flow as measured by the thermal ion instrument compares to the ExB drift as measured by the electric field instrument and to the neutral wind measurements from the Fabry-Perot interferometer. Further analysis of the particle data will yield the ion temperature, whose validity we will quantify by comparison to sheath models.

  20. CMOS image sensor with lateral electric field modulation pixels for fluorescence lifetime imaging with sub-nanosecond time response

    NASA Astrophysics Data System (ADS)

    Li, Zhuo; Seo, Min-Woong; Kagawa, Keiichiro; Yasutomi, Keita; Kawahito, Shoji

    2016-04-01

    This paper presents the design and implementation of a time-resolved CMOS image sensor with a high-speed lateral electric field modulation (LEFM) gating structure for time domain fluorescence lifetime measurement. Time-windowed signal charge can be transferred from a pinned photodiode (PPD) to a pinned storage diode (PSD) by turning on a pair of transfer gates, which are situated beside the channel. Unwanted signal charge can be drained from the PPD to the drain by turning on another pair of gates. The pixel array contains 512 (V) × 310 (H) pixels with 5.6 × 5.6 µm2 pixel size. The imager chip was fabricated using 0.11 µm CMOS image sensor process technology. The prototype sensor has a time response of 150 ps at 374 nm. The fill factor of the pixels is 5.6%. The usefulness of the prototype sensor is demonstrated for fluorescence lifetime imaging through simulation and measurement results.

  1. Graph-Based Semantic Web Service Composition for Healthcare Data Integration.

    PubMed

    Arch-Int, Ngamnij; Arch-Int, Somjit; Sonsilphong, Suphachoke; Wanchai, Paweena

    2017-01-01

    Within the numerous and heterogeneous web services offered through different sources, automatic web services composition is the most convenient method for building complex business processes that permit invocation of multiple existing atomic services. The current solutions in functional web services composition lack autonomous queries of semantic matches within the parameters of web services, which are necessary in the composition of large-scale related services. In this paper, we propose a graph-based Semantic Web Services composition system consisting of two subsystems: management time and run time. The management-time subsystem is responsible for dependency graph preparation in which a dependency graph of related services is generated automatically according to the proposed semantic matchmaking rules. The run-time subsystem is responsible for discovering the potential web services and nonredundant web services composition of a user's query using a graph-based searching algorithm. The proposed approach was applied to healthcare data integration in different health organizations and was evaluated according to two aspects: execution time measurement and correctness measurement.

  2. Graph-Based Semantic Web Service Composition for Healthcare Data Integration

    PubMed Central

    2017-01-01

    Within the numerous and heterogeneous web services offered through different sources, automatic web services composition is the most convenient method for building complex business processes that permit invocation of multiple existing atomic services. The current solutions in functional web services composition lack autonomous queries of semantic matches within the parameters of web services, which are necessary in the composition of large-scale related services. In this paper, we propose a graph-based Semantic Web Services composition system consisting of two subsystems: management time and run time. The management-time subsystem is responsible for dependency graph preparation in which a dependency graph of related services is generated automatically according to the proposed semantic matchmaking rules. The run-time subsystem is responsible for discovering the potential web services and nonredundant web services composition of a user's query using a graph-based searching algorithm. The proposed approach was applied to healthcare data integration in different health organizations and was evaluated according to two aspects: execution time measurement and correctness measurement. PMID:29065602

  3. Mach-Zehnder interferometry method for acoustic shock wave measurements in air and broadband calibration of microphones.

    PubMed

    Yuldashev, Petr; Karzova, Maria; Khokhlova, Vera; Ollivier, Sébastien; Blanc-Benon, Philippe

    2015-06-01

    A Mach-Zehnder interferometer is used to measure spherically diverging N-waves in homogeneous air. An electrical spark source is used to generate high-amplitude (1800 Pa at 15 cm from the source) and short duration (50 μs) N-waves. Pressure waveforms are reconstructed from optical phase signals using an Abel-type inversion. It is shown that the interferometric method allows one to reach 0.4 μs of time resolution, which is 6 times better than the time resolution of a 1/8-in. condenser microphone (2.5 μs). Numerical modeling is used to validate the waveform reconstruction method. The waveform reconstruction method provides an error of less than 2% with respect to amplitude in the given experimental conditions. Optical measurement is used as a reference to calibrate a 1/8-in. condenser microphone. The frequency response function of the microphone is obtained by comparing the spectra of the waveforms resulting from optical and acoustical measurements. The optically measured pressure waveforms filtered with the microphone frequency response are in good agreement with the microphone output voltage. Therefore, an optical measurement method based on the Mach-Zehnder interferometer is a reliable tool to accurately characterize evolution of weak shock waves in air and to calibrate broadband acoustical microphones.

  4. A Sensor-Independent Gust Hazard Metric

    NASA Technical Reports Server (NTRS)

    Stewart, Eric C.

    2001-01-01

    A procedure for calculating an intuitive hazard metric for gust effects on airplanes is described. The hazard metric is for use by pilots and is intended to replace subjective pilot reports (PIREPs) of the turbulence level. The hazard metric is composed of three numbers: the first describes the average airplane response to the turbulence, the second describes the positive peak airplane response to the gusts, and the third describes the negative peak airplane response to the gusts. The hazard metric is derived from any time history of vertical gust measurements and is thus independent of the sensor making the gust measurements. The metric is demonstrated for one simulated airplane encountering different types of gusts including those derived from flight data recorder measurements of actual accidents. The simulated airplane responses to the gusts compare favorably with the hazard metric.

  5. Time-of-flight Measurement Of Hole-tunneling Properties And Emission Color Control In Organic Light-emitting Diodes

    NASA Astrophysics Data System (ADS)

    Kurata, K.; Kashiwabara, K.; Nakajima, K.; Mizoguchi, Y.; Ohtani, N.

    2011-12-01

    Hole transport properties of organic light-emitting diodes (OLEDs) with a thin hole-blocking layer (HBL) were evaluated by time-of-flight measurement. Electroluminescence (EL) spectra of OLEDs with various HBL thicknesses were also evaluated. The results clearly show that the time-resolved photocurrent response and the emission color strongly depend on HBL thickness. This can be attributed to hole-tunneling through the thin HBL. We successfully fabricated a white OLED by controlling the thickness of HBL.

  6. Time-resolved explosion of intense-laser-heated clusters.

    PubMed

    Kim, K Y; Alexeev, I; Parra, E; Milchberg, H M

    2003-01-17

    We investigate the femtosecond explosive dynamics of intense laser-heated argon clusters by measuring the cluster complex transient polarizability. The time evolution of the polarizability is characteristic of competition in the optical response between supercritical and subcritical density regions of the expanding cluster. The results are consistent with time-resolved Rayleigh scattering measurements, and bear out the predictions of a recent laser-cluster interaction model [H. M. Milchberg, S. J. McNaught, and E. Parra, Phys. Rev. E 64, 056402 (2001)

  7. Maternal Responsiveness Predicts Child Language at Ages 3 and 4 in a Community-Based Sample of Slow-to-Talk Toddlers

    ERIC Educational Resources Information Center

    Hudson, Sophie; Levickis, Penny; Down, Kate; Nicholls, Ruth; Wake, Melissa

    2015-01-01

    Background: Maternal responsiveness has been shown to predict child language outcomes in clinical samples of children with language delay and non-representative samples of typically developing children. An effective and timely measure of maternal responsiveness for use at the population level has not yet been established. Aims: To determine…

  8. Body composition impacts appetite regulation in middle childhood. A prospective study of Norwegian community children.

    PubMed

    Steinsbekk, Silje; Llewellyn, Clare H; Fildes, Alison; Wichstrøm, Lars

    2017-05-30

    Research suggests a role for both fat mass and muscle mass in appetite regulation, but the longitudinal relationships between them have not yet been examined in children. The present study therefore aimed to explore the prospective relationships between fat mass, muscle mass and the appetitive traits food responsiveness and satiety responsiveness in middle childhood. Food responsiveness and satiety responsiveness were measured using the parent-reported Children's Eating Behavior Questionnaire in a representative sample of Norwegian 6 year olds, followed up at 8 and 10 years of age (n = 807). Body composition was measured by bioelectrical impedance. Applying a structural equation modeling framework we found that higher fat mass predicted greater increases in food responsiveness over time, whereas greater muscle mass predicted decreases in satiety responsiveness. This pattern was consistent both from ages 6 to 8 and from ages 8 to 10 years. Our study is the first to reveal that fat mass and muscle mass predict distinct changes in different appetitive traits over time. Replication of findings in non-European populations are needed, as are studies of children in other age groups. Future studies should also aim to reveal the underlying mechanisms.

  9. Low-frequency dynamic response of the bismuth strontium ferrite (Bi,Sr)FeO3- x

    NASA Astrophysics Data System (ADS)

    Pronin, A. A.; Torgashev, V. I.; Bush, A. A.; Gorshunov, B. P.; Volkov, A. A.; Prokhorov, A. S.

    2009-03-01

    Broad-range measurements of the dynamic response of polycrystalline samples of the (Bi,Sr)FeO3- x perovskite-like solid solution are performed over a frequency range from 10 Hz to 1 GHz at temperatures of 100-300 K for the first time. The colossal dielectric constant effect and the influence of electric contacts on the results of measurements are considered. It is shown that the frequency dependences of the permittivity and dynamic conductivity of (Bi,Sr)FeO3- x samples can be described within the universal dielectric response model.

  10. Real-time micro-vibration multi-spot synchronous measurement within a region based on heterodyne interference

    NASA Astrophysics Data System (ADS)

    Lan, Ma; Xiao, Wen; Chen, Zonghui; Hao, Hongliang; Pan, Feng

    2018-01-01

    Real-time micro-vibration measurement is widely used in engineering applications. It is very difficult for traditional optical detection methods to achieve real-time need in a relatively high frequency and multi-spot synchronous measurement of a region at the same time,especially at the nanoscale. Based on the method of heterodyne interference, an experimental system of real-time measurement of micro - vibration is constructed to satisfy the demand in engineering applications. The vibration response signal is measured by combing optical heterodyne interferometry and a high-speed CMOS-DVR image acquisition system. Then, by extracting and processing multiple pixels at the same time, four digital demodulation technique are implemented to simultaneously acquire the vibrating velocity of the target from the recorded sequences of images. Different kinds of demodulation algorithms are analyzed and the results show that these four demodulation algorithms are suitable for different interference signals. Both autocorrelation algorithm and cross-correlation algorithm meet the needs of real-time measurements. The autocorrelation algorithm demodulates the frequency more accurately, while the cross-correlation algorithm is more accurate in solving the amplitude.

  11. Millimeter-wave monolithic integrated circuit characterization by a picosecond optoelectronic technique

    NASA Astrophysics Data System (ADS)

    Hung, Hing-Loi A.; Smith, Thane; Huang, Ho C.; Polak-Dingels, Penny; Webb, Kevin J.

    1989-08-01

    The characterization of microwave and millimeter-wave monolithic integrated circits (MIMICs) using picosecond pulse-sampling techniques is developed with emphasis on improving broadband coverage and measurement accuracy. GaAs photoconductive swithces are used for signal generation and sampling operations. The measured time-domain response allows the spectral transfer function of the MIMIC to be obtained. This measurement technique is verified by characterization of the frequency response (magnitude and phase) of a reference 50-ohm microstrip line and a two-stage Ka-band MIMIC amplifier. The measured broadband results agree with those obtained from conventional frequency-domain measurements using a network analyzer. The application of this optical technique to on-wafer MIMIC characterization is described.

  12. Ionospheric convection during the magnetic storm of 20-21 March 1991

    NASA Technical Reports Server (NTRS)

    Taylor, J. R.; Yeoman, T. K.; Lester, M.; Buonsanto, M. J.; Scali, J. L.; Ruohoniemi, J. M.; Kelly, J. D.

    1994-01-01

    We report on the response of high-latitude ionospheric convection during the magnetic storm of March 20-21 1990. IMP-8 measurements of solar wind plasma and interplanetary magnetic field (IMF), ionospheric convection flow measurements from the Wick and Goose Bay coherent radars, EISCAT, Millstone Hill and Sondrestorm incoherent radars and three digisondes at Millstone Hill, Goose Bay and Qaanaaq are presented. Two intervals of particular interest have been indentified. The first starts with a storm sudden commencement at 2243 UT on March 20 and includes the ionospheric activity in the following 7 h. The response time of the ionospheric convection to the southward tuning of the IMF in the dusk to midnight local times is found to be approximately half that measured in a similar study at comparable local times during more normal solar wind conditions. A subsequent reconfiguration of the nightside convection pattern was also observed, although it was not possible to distinguish between effects due to possible changes in B(sub y) and effects due to substorm activity. The second interval, 1200-2100 UT 21 March 1990, included a southward turning of the IMF which resulted in the B(sub z) component becoming -10 nT. The response time on the dayside to this change in the IMF at the magnetopause was approximately 15 min to 30 min which is a factor of approximately 2 greater than those previously measured at higher latitudes. A movement of the nightside flow reversal, possibly driven by current systems associated with the substorm expansion phases, was observed, implying that the nightside convection pattern can be dominated by substorm activity.

  13. Characterization of swallow modulation in response to bolus volume in healthy subjects accounting for catheter diameter.

    PubMed

    Ferris, Lara; Schar, Mistyka; McCall, Lisa; Doeltgen, Sebastian; Scholten, Ingrid; Rommel, Nathalie; Cock, Charles; Omari, Taher

    2018-06-01

    Characterization of the pharyngeal swallow response to volume challenges is important for swallowing function assessment. The diameter of the pressure-impedance recording catheter may influence these results. In this study, we captured key physiological swallow measures in response to bolus volume utilizing recordings acquired by two catheters of different diameter. Ten healthy adults underwent repeat investigations with 8- and 10-Fr catheters. Liquid bolus swallows of volumes 2.5, 5, 10, 20, and 30 mL were recorded. Measures indicative of distension, contractility, and flow timing were assessed. Pressure-impedance recordings with pressure-flow analysis were used to capture key distension, contractility, and pressure-flow timing parameters. Larger bolus volumes increased upper esophageal sphincter distension diameter (P < .001) and distension pressures within the hypopharynx and upper esophageal sphincter (P < .05). Bolus flow timing measures were longer, particularly latency of bolus propulsion ahead of the pharyngeal stripping wave (P < .001). Use of a larger-diameter catheter produced higher occlusive pressures, namely upper esophageal sphincter basal pressure (P < .005) and upper esophageal sphincter postdeglutitive pressure peak (P < .001). The bolus volume swallowed changed measurements indicative of distension pressure, luminal diameter, and pressure-flow timing; this is physiologically consistent with swallow modulation to accommodate larger, faster-flowing boluses. Additionally, catheter diameter predominantly affects lumen occlusive pressures. Appropriate physiological interpretation of the pressure-impedance recordings of pharyngeal swallowing requires consideration of the effects of volume and catheter diameter. NA. Laryngoscope, 128:1328-1334, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  14. Average Dielectric Property Analysis of Complex Breast Tissue with Microwave Transmission Measurements

    PubMed Central

    Garrett, John D.; Fear, Elise C.

    2015-01-01

    Prior information about the average dielectric properties of breast tissue can be implemented in microwave breast imaging techniques to improve the results. Rapidly providing this information relies on acquiring a limited number of measurements and processing these measurement with efficient algorithms. Previously, systems were developed to measure the transmission of microwave signals through breast tissue, and simplifications were applied to estimate the average properties. These methods provided reasonable estimates, but they were sensitive to multipath. In this paper, a new technique to analyze the average properties of breast tissues while addressing multipath is presented. Three steps are used to process transmission measurements. First, the effects of multipath were removed. In cases where multipath is present, multiple peaks were observed in the time domain. A Tukey window was used to time-gate a single peak and, therefore, select a single path through the breast. Second, the antenna response was deconvolved from the transmission coefficient to isolate the response from the tissue in the breast interior. The antenna response was determined through simulations. Finally, the complex permittivity was estimated using an iterative approach. This technique was validated using simulated and physical homogeneous breast models and tested with results taken from a recent patient study. PMID:25585106

  15. Water Stress Impacts Tree-Atmosphere Interaction in the Amazon

    NASA Astrophysics Data System (ADS)

    van Emmerik, T. H. M.; Steele-Dunne, S. C.; Gentine, P.; Oliveira, R. S.; Van De Giesen, N.

    2017-12-01

    Land-atmosphere interactions depend on momentum exchange from the atmosphere to the canopy, which depends on the tree drag coefficient. It is known that the drag coefficient, and thus tree-atmosphere interaction, can vary strongly within a canopy. Yet, only few measurements are available to study the variation of tree-atmosphere interaction in time and space, and in response to vegetation water stress. Recent work [1] demonstrated how accelerometers can be used to study tree properties and responses. For this study, accelerometers were used to derive a measure of tree-atmosphere interaction for 19 individual trees of seven different species in the Brazilian Amazon. This study demonstrates that under field conditions, tree-atmosphere interaction can vary considerably in time and space. The five month measurement period included the transitioning from the wet to the dry season. We demonstrate that increased tree water deficit, measured with dendrometers, is related to observed changes in tree-atmosphere interaction, which is hypothesized to be caused by water stress induced changes in tree mass. References [1]. van Emmerik, T.; Steele-Dunne, S.; Hut, R.; Gentine, P.; Guerin, M.; Oliveira, R.S.; Wagner, J.; Selker, J.; van de Giesen, N. Measuring Tree Properties and Responses Using Low-Cost Accelerometers. Sensors 2017, 17, 1098.

  16. Dissolved oxygen measurements in aquatic environments: the effects of changing temperature and pressure on three sensor technologies.

    PubMed

    Markfort, Corey D; Hondzo, Miki

    2009-01-01

    Dissolved oxygen (DO) is probably the most important parameter related to water quality and biological habitat in aquatic environments. In situ DO sensors are some of the most valuable tools used by scientists and engineers for the evaluation of water quality in aquatic ecosystems. Presently, we cannot accurately measure DO concentrations under variable temperature and pressure conditions. Pressure and temperature influence polarographic and optical type DO sensors compared to the standard Winkler titration method. This study combines laboratory and field experiments to compare and quantify the accuracy and performance of commercially available macro and micro Clark-type oxygen sensors as well as optical sensing technology to the Winkler method under changing pressure and temperature conditions. Field measurements at various lake depths revealed sensor response time up to 11 min due to changes in water temperature, pressure, and DO concentration. Investigators should account for transient response in DO sensors before measurements are collected at a given location. We have developed an effective model to predict the transient response time for Clark-type oxygen sensors. The proposed procedure increases the accuracy of DO data collected in situ for profiling applications.

  17. Signal and background considerations for the MRSt on the National Ignition Facility (NIF).

    PubMed

    Wink, C W; Frenje, J A; Hilsabeck, T J; Bionta, R; Khater, H Y; Gatu Johnson, M; Kilkenny, J D; Li, C K; Séguin, F H; Petrasso, R D

    2016-11-01

    A Magnetic Recoil Spectrometer (MRSt) has been conceptually designed for time-resolved measurements of the neutron spectrum at the National Ignition Facility. Using the MRSt, the goals are to measure the time-evolution of the spectrum with a time resolution of ∼20-ps and absolute accuracy better than 5%. To meet these goals, a detailed understanding and optimization of the signal and background characteristics are required. Through ion-optics, MCNP simulations, and detector-response calculations, it is demonstrated that the goals and a signal-to background >5-10 for the down-scattered neutron measurement are met if the background, consisting of ambient neutrons and gammas, at the MRSt is reduced 50-100 times.

  18. The influence of urban, suburban, or rural locale on survival from refractory prehospital cardiac arrest.

    PubMed

    Vukmir, Rade B

    2004-03-01

    There are many variables that can have an effect on survival in cardiopulmonary arrest. This study examined the effect of urban, suburban, or rural location on the outcome of prehospital cardiac arrest as a secondary end point in a study evaluating the effect of bicarbonate on survival. The proportion of survivors within a type of EMS provider system as well as response times were compared. This prospective, randomized, double-blind clinical intervention trial enrolled 874 prehospital cardiopulmonary arrest patients encountered by prehospital urban, suburban, and rural regional EMS area. Population density (patients per square mile) calculation allowed classification into urban (>2000/mi2), suburban (>400/mi2), and rural (0-399/mi2) systems. This group underwent standard advanced cardiac life support (ACLS) intervention with or without early empiric administration of bicarbonate in a 1-mEq/kg dose. A group of demographic, diagnostic, and therapeutic variables were analyzed for their effect on survival. Times were measured from collapse until onset of medical intervention and survival measured as the presence of ED vital signs on arrival. Data analysis used chi-squared with Pearson correlation for survivorship and Student t test comparisons for response times. The overall survival rate was approximately 13.9% (110 of 793), ranging from 9% rural, 14% for suburban, and 23% for urban sites for 372 patients (P=.007). Survival differences were associated with classification of arrest locale in this sample-best for urban, suburban, followed by rural sites. There was no difference in time to bystander cardiopulmonary resuscitation, but medical response time (basic life support) was decreased for suburban or urban sites, and intervention (ACLS) and transport times were decreased for suburban sites alone. Although response times were differentiated by location, they were not necessarily predictive of survival. Factors other than response time such as patient population or resuscitation skill could influence survival from cardiac arrest occurring in diverse prehospital service areas.

  19. Spectral response model for a multibin photon-counting spectral computed tomography detector and its applications.

    PubMed

    Liu, Xuejin; Persson, Mats; Bornefalk, Hans; Karlsson, Staffan; Xu, Cheng; Danielsson, Mats; Huber, Ben

    2015-07-01

    Variations among detector channels in computed tomography can lead to ring artifacts in the reconstructed images and biased estimates in projection-based material decomposition. Typically, the ring artifacts are corrected by compensation methods based on flat fielding, where transmission measurements are required for a number of material-thickness combinations. Phantoms used in these methods can be rather complex and require an extensive number of transmission measurements. Moreover, material decomposition needs knowledge of the individual response of each detector channel to account for the detector inhomogeneities. For this purpose, we have developed a spectral response model that binwise predicts the response of a multibin photon-counting detector individually for each detector channel. The spectral response model is performed in two steps. The first step employs a forward model to predict the expected numbers of photon counts, taking into account parameters such as the incident x-ray spectrum, absorption efficiency, and energy response of the detector. The second step utilizes a limited number of transmission measurements with a set of flat slabs of two absorber materials to fine-tune the model predictions, resulting in a good correspondence with the physical measurements. To verify the response model, we apply the model in two cases. First, the model is used in combination with a compensation method which requires an extensive number of transmission measurements to determine the necessary parameters. Our spectral response model successfully replaces these measurements by simulations, saving a significant amount of measurement time. Second, the spectral response model is used as the basis of the maximum likelihood approach for projection-based material decomposition. The reconstructed basis images show a good separation between the calcium-like material and the contrast agents, iodine and gadolinium. The contrast agent concentrations are reconstructed with more than 94% accuracy.

  20. Spectral response model for a multibin photon-counting spectral computed tomography detector and its applications

    PubMed Central

    Liu, Xuejin; Persson, Mats; Bornefalk, Hans; Karlsson, Staffan; Xu, Cheng; Danielsson, Mats; Huber, Ben

    2015-01-01

    Abstract. Variations among detector channels in computed tomography can lead to ring artifacts in the reconstructed images and biased estimates in projection-based material decomposition. Typically, the ring artifacts are corrected by compensation methods based on flat fielding, where transmission measurements are required for a number of material-thickness combinations. Phantoms used in these methods can be rather complex and require an extensive number of transmission measurements. Moreover, material decomposition needs knowledge of the individual response of each detector channel to account for the detector inhomogeneities. For this purpose, we have developed a spectral response model that binwise predicts the response of a multibin photon-counting detector individually for each detector channel. The spectral response model is performed in two steps. The first step employs a forward model to predict the expected numbers of photon counts, taking into account parameters such as the incident x-ray spectrum, absorption efficiency, and energy response of the detector. The second step utilizes a limited number of transmission measurements with a set of flat slabs of two absorber materials to fine-tune the model predictions, resulting in a good correspondence with the physical measurements. To verify the response model, we apply the model in two cases. First, the model is used in combination with a compensation method which requires an extensive number of transmission measurements to determine the necessary parameters. Our spectral response model successfully replaces these measurements by simulations, saving a significant amount of measurement time. Second, the spectral response model is used as the basis of the maximum likelihood approach for projection-based material decomposition. The reconstructed basis images show a good separation between the calcium-like material and the contrast agents, iodine and gadolinium. The contrast agent concentrations are reconstructed with more than 94% accuracy. PMID:26839904

  1. A Review of Player Monitoring Approaches in Basketball: Current Trends and Future Directions.

    PubMed

    Fox, Jordan L; Scanlan, Aaron T; Stanton, Robert

    2017-07-01

    Fox, JL, Scanlan, AT, and Stanton, R. A review of player monitoring approaches in basketball: current trends and future directions. J Strength Cond Res 31(7): 2021-2029, 2017-Effective monitoring of players in team sports such as basketball requires an understanding of the external demands and internal responses, as they relate to training phases and competition. Monitoring of external demands and internal responses allows coaching staff to determine the dose-response associated with the imposed training load (TL), and subsequently, if players are adequately prepared for competition. This review discusses measures reported in the literature for monitoring the external demands and internal responses of basketball players during training and competition. The external demands of training and competition were primarily monitored using time-motion analysis, with limited use of microtechnology being reported. Internal responses during training were typically measured using hematological markers, heart rate, various TL models, and perceptual responses such as rating of perceived exertion (RPE). Heart rate was the most commonly reported indicator of internal responses during competition with limited reporting of hematological markers or RPE. These findings show a large discrepancy between the reporting of external and internal measures and training and competition demands. Microsensors, however, may be a practical and convenient method of player monitoring in basketball to overcome the limitations associated with current approaches while allowing for external demands and internal responses to be recorded simultaneously. The triaxial accelerometers of microsensors seem well suited for basketball and warrant validation to definitively determine their place in the monitoring of basketball players. Coaching staff should make use of this technology by tracking individual player responses across the annual plan and using real-time monitoring to minimize factors such as fatigue and injury risk.

  2. Lock-in amplifier error prediction and correction in frequency sweep measurements.

    PubMed

    Sonnaillon, Maximiliano Osvaldo; Bonetto, Fabian Jose

    2007-01-01

    This article proposes an analytical algorithm for predicting errors in lock-in amplifiers (LIAs) working with time-varying reference frequency. Furthermore, a simple method for correcting such errors is presented. The reference frequency can be swept in order to measure the frequency response of a system within a given spectrum. The continuous variation of the reference frequency produces a measurement error that depends on three factors: the sweep speed, the LIA low-pass filters, and the frequency response of the measured system. The proposed error prediction algorithm is based on the final value theorem of the Laplace transform. The correction method uses a double-sweep measurement. A mathematical analysis is presented and validated with computational simulations and experimental measurements.

  3. Measuring atmospheric visibility cavity attenuated phase shift spectroscopy

    NASA Astrophysics Data System (ADS)

    Jie, Guo; Ye, Shan-Shan; Yang, Xiao; Han, Ye-Xing; Tang, Huai-Wu; Yu, Zhi-Wei

    2016-10-01

    In the paper, an accurate and sensitive cavity attenuated phase shift spectroscopy (CAPS) system was used to monitor the atmospheric visibility coefficient in urban areas. The CAPS system, which detects the atmospheric visibility within a 10 nm bandpass centered at 532 nm, comprises a green LED with center wavelength in 532nm, a resonant optical cavity (36 cm length), a Photo Multiplier Tube detector and a lock in amplifier. The performance of the CAPS system was evaluated by measuring of the stability and response of the system. The minima ( 0.06 Mm-1) in the Allan plots show the optimum average time( 80s) for optimum detection performance of the CAPS system. The 2L/min flow rate, the CAPS system rise and fall response time is about 15 s, so as to realize the fast measurement of visibility. By comparing the forward scatter visibility meter measurement results, the CAPS system measurement results are verified reliably, and have high precision measurement. These figures indicate that this method has the potential to become one of the most sensitive on-line analytical techniques for atmospheric visibility detection.

  4. Time-of-flight radio location system

    DOEpatents

    McEwan, T.E.

    1997-08-26

    A bi-static radar configuration measures the direct time-of-flight of a transmitted RF pulse and is capable of measuring this time-of-flight with a jitter on the order of about one pico-second, or about 0.01 inch of free space distance for an electromagnetic pulse over a range of about one to ten feet. A transmitter transmits a sequence of electromagnetic pulses in response to a transmit timing signal, and a receiver samples the sequence of electromagnetic pulses with controlled timing in response to a receive timing signal, and generates a sample signal in response to the samples. A timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the sequence of electromagnetic pulses such that the time between transmission of pulses in the sequence and sampling by the receiver sweeps over a range of delays. The receive timing signal sweeps over the range of delays in a sweep cycle such that pulses in the sequence are sampled at the pulse repetition rate, and with different delays in the range of delays to produce a sample signal representing magnitude of a received pulse in equivalent time. Automatic gain control circuitry in the receiver controls the magnitude of the equivalent time sample signal. A signal processor analyzes the sample signal to indicate the time-of-flight of the electromagnetic pulses in the sequence. The sample signal in equivalent time is passed through an envelope detection circuit, formed of an absolute value circuit followed by a low pass filter, to convert the sample signal to a unipolar signal to eliminate effects of antenna misorientation. 8 figs.

  5. Time-of-flight radio location system

    DOEpatents

    McEwan, Thomas E.

    1997-01-01

    A bi-static radar configuration measures the direct time-of-flight of a transmitted RF pulse and is capable of measuring this time-of-flight with a jitter on the order of about one pico-second, or about 0.01 inch of free space distance for an electromagnetic pulse over a range of about one to ten feet. A transmitter transmits a sequence of electromagnetic pulses in response to a transmit timing signal, and a receiver samples the sequence of electromagnetic pulses with controlled timing in response to a receive timing signal, and generates a sample signal in response to the samples. A timing circuit supplies the transmit timing signal to the transmitter and supplies the receive timing signal to the receiver. The receive timing signal causes the receiver to sample the sequence of electromagnetic pulses such that the time between transmission of pulses in the sequence and sampling by the receiver sweeps over a range of delays. The receive timing signal sweeps over the range of delays in a sweep cycle such that pulses in the sequence are sampled at the pulse repetition rate, and with different delays in the range of delays to produce a sample signal representing magnitude of a received pulse in equivalent time. Automatic gain control circuitry in the receiver controls the magnitude of the equivalent time sample signal. A signal processor analyzes the sample signal to indicate the time-of-flight of the electromagnetic pulses in the sequence. The sample signal in equivalent time is passed through an envelope detection circuit, formed of an absolute value circuit followed by a low pass filter, to convert the sample signal to a unipolar signal to eliminate effects of antenna misorientation.

  6. Waveform difference between skin conductance and skin potential responses in relation to electrical and evaporative properties of skin.

    PubMed

    Tronstad, Christian; Kalvøy, Håvard; Grimnes, Sverre; Martinsen, Ørjan G

    2013-11-01

    The shapes of skin conductance (SC) and skin potential (SP) responses are often similar, but can also be very different due to an unexplained cause. Using a new method to measure SC and SP simultaneously at the same electrode, this difference was investigated in a new way by comparing their temporal peak differences. SC, SP, skin susceptance (SS), and transepidermal water loss (TEWL) were recorded from 40 participants during relaxation and stress. The SP response could peak anywhere between the onset of an SC response to some time after the peak of an SC response. This peak time difference was associated with the magnitude of the SCR, the hydration of the skin, and the filling of the sweat ducts. Interpretation of the results in light of existing biophysical theories suggests that this peak difference may indicate the hydraulic capacity state of the sweat ducts at the time of a response. Copyright © 2013 Society for Psychophysiological Research.

  7. Response preparation and intra-individual reaction time variability in schizophrenia.

    PubMed

    Dankinas, Denisas; Mėlynytė, Sigita; Šiurkutė, Aldona; Dapšys, Kastytis

    2016-01-01

    Background. It is important to prepare response in advance to increase the efficiency of its execution. The process of response preparation is usually studied using the precueing paradigm. In this paradigm subjects have to employ the preceding information about further imperative stimulus to perform proper response preparation, which shortens the reaction time of subsequent response execution. Previous studies detected the impairment of response preparation in schizophrenia only with the help of electroencephalographic parameters, but not with the assessing of reaction time. Therefore, in this study we attempted to find a behavioural parameter that could detect impairment in response preparation of schizophrenia patients. It was recently found that appropriate response preparation not only shortens the reaction time but also increases its stability, which is measured with the intra-individual reaction time variability. It was also revealed that response stability could better find cognitive dysfunction in some studies of schizophrenia disorder than classical behavioural parameters. Hence, the main goal of this study was to verify if intra-individual reaction time variability could detect the impairment of response preparation in schizophrenia patients. Materials and methods. In order to achieve the main purpose, we carried out a study with 14 schizophrenia patients and 14 control group subjects. We used precueing paradigm in our research, in which participants had to employ information about stimulus probability for the proper response preparation. Results. Our main result showed that despite the responses of schizophrenia patients were faster to the high-probability stimulus than to the low-probability one ( F (1, 13) = 30.9, p < 0.001), intra-individual reaction time variability did not differ in this group between the responses to more and less probable stimuli ( F (1, 13) = 0.64, p = 0.44). Conclusions. Results of the study suggest that people with schizophrenia were able to use precueing probabilistic information only to shorten their reaction time, but not to increase response stability. Therefore, it was found that intra-individual reaction time variability parameter could detect response preparation impairment in schizophrenia, and could be used in clinical purposes.

  8. Comparison of non-invasive measures of cholinergic and allergic airway responsiveness in rats.

    PubMed

    Glaab, T; Hecker, H; Stephan, M; Baelder, R; Braun, A; Korolewitz, R; Krug, N; Hoymann, H G

    2006-04-01

    Non-invasive analysis of tidal expiratory flow parameters such as Tme/TE (time needed to reach peak expiratory flow divided by total expiratory time) or midexpiratory tidal flow (EF50) has been shown useful for phenotypic characterization of lung function in humans and animal models. In this study, we aimed to compare the utility of two non-invasive measures, EF50 and Tme/TE, to monitor bronchoconstriction to inhaled cholinergic and allergic challenges in Brown-Norway rats. Non-invasive measurements of Tme/TE and EF50 were paralleled by invasive recordings of Tme/TE, EF50 and pulmonary conductance (GL). First, dose-response studies with acetylcholine were performed in naive rats, showing that EF50 better than Tme/TE reflected the dose-related changes as observed with the classical invasive outcome parameter GL. The subsequent determination of allergen-specific early airway responsiveness (EAR) showed that ovalbumin-sensitized and -challenged rats exhibited airway inflammation and allergen-specific EAR. Again, EF50 was more sensitive than Tme/TE in detecting the allergen-specific EAR recorded with invasive and non-invasive lung function methods and agreed well with classical GL measurements. We conclude that non-invasive assessment of EF50 is significantly superior to Tme/TE and serves as a suitable and valid tool for phenotypic screening of cholinergic and allergic airway responsiveness in rats.

  9. Real-time measurements of jet aircraft engine exhaust.

    PubMed

    Rogers, Fred; Arnott, Pat; Zielinska, Barbara; Sagebiel, John; Kelly, Kerry E; Wagner, David; Lighty, JoAnn S; Sarofim, Adel F

    2005-05-01

    Particulate-phase exhaust properties from two different types of ground-based jet aircraft engines--high-thrust and turboshaft--were studied with real-time instruments on a portable pallet and additional time-integrated sampling devices. The real-time instruments successfully characterized rapidly changing particulate mass, light absorption, and polycyclic aromatic hydrocarbon (PAH) content. The integrated measurements included particulate-size distributions, PAH, and carbon concentrations for an entire test run (i.e., "run-integrated" measurements). In all cases, the particle-size distributions showed single modes peaking at 20-40nm diameter. Measurements of exhaust from high-thrust F404 engines showed relatively low-light absorption compared with exhaust from a turboshaft engine. Particulate-phase PAH measurements generally varied in phase with both net particulate mass and with light-absorbing particulate concentrations. Unexplained response behavior sometimes occurred with the real-time PAH analyzer, although on average the real-time and integrated PAH methods agreed within the same order of magnitude found in earlier investigations.

  10. Input-output characterization of an ultrasonic testing system by digital signal analysis

    NASA Technical Reports Server (NTRS)

    Williams, J. H., Jr.; Lee, S. S.; Karagulle, H.

    1986-01-01

    Ultrasonic test system input-output characteristics were investigated by directly coupling the transmitting and receiving transducers face to face without a test specimen. Some of the fundamentals of digital signal processing were summarized. Input and output signals were digitized by using a digital oscilloscope, and the digitized data were processed in a microcomputer by using digital signal-processing techniques. The continuous-time test system was modeled as a discrete-time, linear, shift-invariant system. In estimating the unit-sample response and frequency response of the discrete-time system, it was necessary to use digital filtering to remove low-amplitude noise, which interfered with deconvolution calculations. A digital bandpass filter constructed with the assistance of a Blackman window and a rectangular time window were used. Approximations of the impulse response and the frequency response of the continuous-time test system were obtained by linearly interpolating the defining points of the unit-sample response and the frequency response of the discrete-time system. The test system behaved as a linear-phase bandpass filter in the frequency range 0.6 to 2.3 MHz. These frequencies were selected in accordance with the criterion that they were 6 dB below the maximum peak of the amplitude of the frequency response. The output of the system to various inputs was predicted and the results were compared with the corresponding measurements on the system.

  11. Control-enhanced multiparameter quantum estimation

    NASA Astrophysics Data System (ADS)

    Liu, Jing; Yuan, Haidong

    2017-10-01

    Most studies in multiparameter estimation assume the dynamics is fixed and focus on identifying the optimal probe state and the optimal measurements. In practice, however, controls are usually available to alter the dynamics, which provides another degree of freedom. In this paper we employ optimal control methods, particularly the gradient ascent pulse engineering (GRAPE), to design optimal controls for the improvement of the precision limit in multiparameter estimation. We show that the controlled schemes are not only capable to provide a higher precision limit, but also have a higher stability to the inaccuracy of the time point performing the measurements. This high time stability will benefit the practical metrology, where it is hard to perform the measurement at a very accurate time point due to the response time of the measurement apparatus.

  12. Two-color short-pulse laser altimeter measurements of ocean surface backscatter

    NASA Technical Reports Server (NTRS)

    Abshire, James B.; Mcgarry, Jan F.

    1987-01-01

    The timing and correlation properties of pulsed laser backscatter from the ocean surface have been measured with a two-color short-pulse laser altimeter. The Nd:YAG laser transmitted 70- and 35-ps wide pulses simultaneously at 532 and 355 nm at nadir, and the time-resolved returns were recorded by a receiver with 800-ps response time. The time-resolved backscatter measured at both 330-m and 1291-m altitudes showed little pulse broadening due to the submeter laser spot size. The differential delay of the 355-nm and 532-nm backscattered waveforms were measured with a rms error of about 75 ps. The change in aircraft altitudes also permitted the change in atmospheric pressure to be estimated by using the two-color technique.

  13. Physiological responses of low-time private pilots to cross-country flying.

    DOT National Transportation Integrated Search

    1971-04-01

    Various physiological, biochemical, and psychophysiological measurements were made on low-time private pilots who each flew three cross-country flights. The round-trip flights were 320, 520, and 960 NM in length. Heart rate was recorded continuously ...

  14. Time-domain reflectometry of water content in portland cement concrete

    DOT National Transportation Integrated Search

    1997-11-01

    Time-domain reflectometry is useful for measuring the moisture content of solids. However, little information exists on its use with portland cement concrete. By monitoring the response from TDR sensors embedded in concrete as the concrete dried, the...

  15. Emergency medical services and congestion : urban sprawl and pre-hospital emergency care time.

    DOT National Transportation Integrated Search

    2009-01-01

    This research measured the association between urban sprawl and emergency medical service (EMS) response time. The purpose was to test the hypothesis that features of the built environment increase the probability of delayed ambulance arrival. Using ...

  16. Micro-thermocouple probe for measurement of cellular thermal responses.

    PubMed

    Watanabe, M; Kakuta, N; Mabuchi, K; Yamada, Y

    2005-01-01

    We have produced micro-thermocouple probes for the measurement of cellular thermal responses. Cells generate heat with their metabolisms and more heat with reactions to a certain physical or chemical stimulation. Therefore, the analysis of the cellular thermal responses would provide new physiological information. However, a real-time thermal measurement technique on a target of a single cell has not been established. In this study, glass micropipettes, which are widely used in bioengineering and medicine, are used for the base of the thermocouple probes. Using microfabrication techniques, the junction of two different metal films is formed at the micropipette tip with a diameter of 1 μm. This probe can inject a chemical substance into a cell and to detect its subsequent temperature changes simultaneously.

  17. Effects of Microphallus turgidus (Trematoda: Microphallidae) on the predation, behavior, and swimming stamina of the grass shrimp Palaemonetes pugio.

    PubMed

    Kunz, Alyssa K; Pung, Oscar J

    2004-06-01

    The effect of the trematode Microphallus turgidus on its second intermediate host, the grass shrimp, Palaemonetes pugio, was tested. To do so, we measured the susceptibility of infected and uninfected shrimp to predation by the mummichog, Fundulus heteroclitus. Shrimp behavior was compared in the presence and absence of a fish predator, and the swimming stamina and backthrust escape responses of infected and uninfected shrimp were measured. Infected shrimp were more likely to be eaten by a predator than uninfected shrimp, had lower swimming stamina, and spent more time swimming and less time motionless in the presence of a predator. There was no difference between backthrust distances traveled in response to a stimulus by either infected or uninfected shrimp. Thus, M. turgidus may increase the predation of P. pugio in the wild, possibly by affecting the swimming stamina and predator avoidance responses of the shrimp.

  18. Turbulent wind at the equatorial segment of an operating Darrieus wind turbine blade

    NASA Astrophysics Data System (ADS)

    Connell, J. R.; Morris, V. R.

    1989-09-01

    Six turbulent wind time series, measured at equally spaced equator-height locations on a circle 3 m outside a 34-m Darrieus rotor, are analyzed to approximate the wind fluctuations experienced by the rotor. The flatwise lower root-bending stress of one blade was concurrently recorded. The wind data are analyzed in three ways: wind components that are radial and tangential to the rotation of a blade were rotationally sampled; induction and wake effects of the rotor were estimated from the six Eulerian time series; and turbulence spectra of both the measured wind and the modeled wind from the PNL theory of rotationally sampled turbulence. The wind and the rotor response are related by computing the spectral response function of the flatwise lower root-bending stress. Two bands of resonant response that surround the first and second flatwise modal frequencies shift with the rotor rotation rate.

  19. A Cartesian reflex assessment of face processing.

    PubMed

    Polewan, Robert J; Vigorito, Christopher M; Nason, Christopher D; Block, Richard A; Moore, John W

    2006-03-01

    Commands to blink were embedded within pictures of faces and simple geometric shapes or forms. The faces and shapes were conditioned stimuli (CSs), and the required responses were conditioned responses, or more properly, Cartesian reflexes (CRs). As in classical conditioning protocols, response times (RTs) were measured from CS onset. RTs provided a measure of the processing cost (PC) of attending to a CS. A PC is the extra time required to respond relative to RTs to unconditioned stimulus (US) commands presented alone. They reflect the interplay between attentional processing of the informational content of a CS and its signaling function with respect to the US command. This resulted in longer RTs to embedded commands. Differences between PCs of faces and geometric shapes represent a starting place for a new mental chronometry based on the traditional idea that differences in RT reflect differences in information processing.

  20. Heart rate autonomic regulation system at rest and during paced breathing among patients with CRPS as compared to age-matched healthy controls.

    PubMed

    Bartur, Gadi; Vatine, Jean-Jacques; Raphaely-Beer, Noa; Peleg, Sara; Katz-Leurer, Michal

    2014-09-01

    The objective of this study is to assess the autonomic nerve heart rate regulation system at rest and its immediate response to paced breathing among patients with complex regional pain syndrome (CRPS) as compared with age-matched healthy controls. Quasiexperimental. Outpatient clinic. Ten patients with CRPS and 10 age- and sex-matched controls. Participants underwent Holter ECG (NorthEast Monitoring, Inc., Maynard, MA, USA) recording during rest and biofeedback-paced breathing session. Heart rate variability (HRV), time, and frequency measures were assessed. HRV and time domain values were significantly lower at rest among patients with CRPS as compared with controls. A significant association was noted between pain rank and HRV frequency measures at rest and during paced breathing; although both groups reduced breathing rate significantly during paced breathing, HRV time domain parameters increased only among the control group. The increased heart rate and decreased HRV at rest in patients with CRPS suggest a general autonomic imbalance. The inability of the patients to increase HRV time domain values during paced breathing may suggest that these patients have sustained stress response with minimal changeability in response to slow-paced breathing stimuli. Wiley Periodicals, Inc.

  1. Urinary corticosterone metabolite responses to capture and captivity in the cane toad (Rhinella marina).

    PubMed

    Narayan, Edward J; Cockrem, John F; Hero, Jean-Marc

    2011-09-01

    Urinary corticosterone metabolite responses to capture have recently been shown for the first time in amphibians, and in the present study urinary corticosterone metabolite responses to capture and to confinement in captivity were measured in adult cane toads (Rhinella marina) in Queensland, Australia. An adrenocorticotropic hormone (ACTH) challenge was used to provide a biological validation for urinary corticosterone metabolite concentrations measured by radioimmunoassay (RIA). Urinary corticosterone metabolite increased 1-2 days after ACTH but not saline injection and then returned to initial values, indicating that the RIA could detect changes in corticosterone secretion in toads. Urinary corticosterone metabolite responses to short-term capture and restraint in plastic bags were first apparent 2h after capture of wild toads. Toads held communally in captivity for 5 days had elevated urinary corticosterone metabolite concentrations. Mean corticosterone concentrations declined significantly after a further 7 days in individual housing chambers. There was no sex difference in urinary corticosterone metabolite responses of toads to ACTH challenge, short-term capture or captivity. The relative amount of variation in the mean corticosterone responses was quantified by calculating coefficients of variation (CV) for each mean corticosterone response. Mean corticosterone at 0 min was more variable for captive toads than wild toads. Furthermore, initial corticosterone concentrations (0 min) were more variable than concentrations during the ACTH challenge, short-term capture and captivity. There was little change in the amount of variation of mean corticosterone levels between male and female toads with increasing time in captivity (12-29 days). This study has shown individual corticosterone responses of amphibians for the first-time, and has provided a novel method for quantifying the relative amount of variation in amphibian corticosterone responses. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Premature responding is associated with approach to a food cue in male and female heterogeneous stock rats

    PubMed Central

    King, Christopher P.; Palmer, Abraham A.; Solberg Woods, Leah C.; Hawk, Larry W.; Richards, Jerry B.; Meyer, Paul J.

    2016-01-01

    Rationale Disorders of behavioral regulation, including attention deficit hyperactivity disorder (ADHD) and drug addiction, are in part due to poor inhibitory control, attentional deficits, and hyper-responsivity to reward-associated cues. Objectives To determine whether these traits are related, we tested genetically variable male and female heterogeneous stock rats in the choice reaction time (CRT) task and Pavlovian conditioned approach (PavCA). Sex differences in the response to methylphenidate during the CRT were also assessed. Methods In the CRT task, rats were required to withhold responding until one of two lights indicated whether responses into a left or right port would be reinforced with water. Reaction time on correct trials and premature responses were the operational definitions of attention and response inhibition, respectively. Rats were also pre-treated with oral methylphenidate (0, 2, 4 mg/kg) during the CRT task to determine whether this drug would improve performance. Subsequently, during PavCA, presentation of an illuminated lever predicted the delivery of a food pellet into a food-cup. Lever-directed approach (sign-tracking) and food-cup approach (goal-tracking) were the primary measures, and rats were categorized as “sign-trackers” and “goal-trackers” using an index based on these measures. Results Sign-trackers made more premature responses than goal-trackers, but showed no differences in reaction time. There were sex differences in both tasks, with females having higher sign-tracking, completing more CRT trials, and making more premature responses after methylphenidate administration. Conclusions These results indicate that response inhibition is related to reward-cue responsivity, suggesting that these traits are influenced by common genetic factors. PMID:27146401

  3. Crossfit analysis: a novel method to characterize the dynamics of induced plant responses.

    PubMed

    Jansen, Jeroen J; van Dam, Nicole M; Hoefsloot, Huub C J; Smilde, Age K

    2009-12-16

    Many plant species show induced responses that protect them against exogenous attacks. These responses involve the production of many different bioactive compounds. Plant species belonging to the Brassicaceae family produce defensive glucosinolates, which may greatly influence their favorable nutritional properties for humans. Each responding compound may have its own dynamic profile and metabolic relationships with other compounds. The chemical background of the induced response is therefore highly complex and may therefore not reveal all the properties of the response in any single model. This study therefore aims to describe the dynamics of the glucosinolate response, measured at three time points after induction in a feral Brassica, by a three-faceted approach, based on Principal Component Analysis. First the large-scale aspects of the response are described in a 'global model' and then each time-point in the experiment is individually described in 'local models' that focus on phenomena that occur at specific moments in time. Although each local model describes the variation among the plants at one time-point as well as possible, the response dynamics are lost. Therefore a novel method called the 'Crossfit' is described that links the local models of different time-points to each other. Each element of the described analysis approach reveals different aspects of the response. The crossfit shows that smaller dynamic changes may occur in the response that are overlooked by global models, as illustrated by the analysis of a metabolic profiling dataset of the same samples.

  4. Crossfit analysis: a novel method to characterize the dynamics of induced plant responses

    PubMed Central

    2009-01-01

    Background Many plant species show induced responses that protect them against exogenous attacks. These responses involve the production of many different bioactive compounds. Plant species belonging to the Brassicaceae family produce defensive glucosinolates, which may greatly influence their favorable nutritional properties for humans. Each responding compound may have its own dynamic profile and metabolic relationships with other compounds. The chemical background of the induced response is therefore highly complex and may therefore not reveal all the properties of the response in any single model. Results This study therefore aims to describe the dynamics of the glucosinolate response, measured at three time points after induction in a feral Brassica, by a three-faceted approach, based on Principal Component Analysis. First the large-scale aspects of the response are described in a 'global model' and then each time-point in the experiment is individually described in 'local models' that focus on phenomena that occur at specific moments in time. Although each local model describes the variation among the plants at one time-point as well as possible, the response dynamics are lost. Therefore a novel method called the 'Crossfit' is described that links the local models of different time-points to each other. Conclusions Each element of the described analysis approach reveals different aspects of the response. The crossfit shows that smaller dynamic changes may occur in the response that are overlooked by global models, as illustrated by the analysis of a metabolic profiling dataset of the same samples. PMID:20015363

  5. Diabetic Driving Studies-Part 2: A Comparison of Brake Response Time Between Drivers With Diabetes With and Without Lower Extremity Sensorimotor Neuropathy.

    PubMed

    Spiess, Kerianne E; Sansosti, Laura E; Meyr, Andrew J

    We have previously demonstrated an abnormally delayed mean brake response time and an increased frequency of abnormally delayed brake responses in a group of neuropathic drivers with diabetes compared with a control group of drivers with neither diabetes nor lower extremity neuropathy. The objective of the present case-control study was to compare the mean brake response time between 2 groups of drivers with diabetes with and without lower extremity sensorimotor neuropathy. The braking performances of the participants were evaluated using a computerized driving simulator with specific measurement of the mean brake response time and the frequency of the abnormally delayed brake responses. We compared a control group of 25 active drivers with type 2 diabetes without lower extremity neuropathy and an experimental group of 25 active drivers with type 2 diabetes and lower extremity neuropathy from an urban U.S. podiatric medical clinic. The experimental group demonstrated an 11.49% slower mean brake response time (0.757 ± 0.180 versus 0.679 ± 0.120 second; p < .001), with abnormally delayed reactions occurring at a greater frequency (57.5% versus 35.0%; p < .001). Independent of a comparative statistical analysis, diabetic drivers with neuropathy demonstrated a mean brake response time slower than a suggested safety threshold of 0.70 second, and diabetic drivers without neuropathy demonstrated a mean brake response time faster than this threshold. The results of the present investigation provide evidence that the specific onset of lower extremity sensorimotor neuropathy associated with diabetes appears to impart a negative effect on automobile brake responses. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  6. Real-Time Assessment of Mechanical Tissue Trauma in Surgery.

    PubMed

    Chandler, James H; Mushtaq, Faisal; Moxley-Wyles, Benjamin; West, Nicholas P; Taylor, Gregory W; Culmer, Peter R

    2017-10-01

    This work presents a method to assess and prevent tissue trauma in real-time during surgery. Tissue trauma occurs routinely during laparoscopic surgery with potentially severe consequences. As such, it is crucial that a surgeon is able to regulate the pressure exerted by surgical instruments. We propose a novel method to assess the onset of tissue trauma by considering the mechanical response of tissue as it is loaded in real-time. We conducted a parametric study using a lab-based grasping model and differing load conditions. Mechanical stress-time data were analyzed to characterize the tissue response to grasps. Qualitative and quantitative histological analyses were performed to inspect damage characteristics of the tissue under different load conditions. These were correlated against the mechanical measures to identify the nature of trauma onset with respect to our predictive metric. Results showed increasing tissue trauma with load and a strong correlation with the mechanical response of the tissue. Load rate and load history also showed a clear effect on tissue response. The proposed method for trauma assessment was effective in identifying damage. The metric can be normalized with respect to loading rate and history, making it feasible in the unconstrained environment of intraoperative surgery. This work demonstrates that tissue trauma can be predicted using mechanical measures in real-time. Applying this technique to laparoscopic tools has the potential to reduce unnecessary tissue trauma and its associated complications by indicating through user feedback or actively regulating the mechanical impact of surgical instruments.

  7. How attention influences perceptual decision making: Single-trial EEG correlates of drift-diffusion model parameters

    PubMed Central

    Nunez, Michael D.; Vandekerckhove, Joachim; Srinivasan, Ramesh

    2016-01-01

    Perceptual decision making can be accounted for by drift-diffusion models, a class of decision-making models that assume a stochastic accumulation of evidence on each trial. Fitting response time and accuracy to a drift-diffusion model produces evidence accumulation rate and non-decision time parameter estimates that reflect cognitive processes. Our goal is to elucidate the effect of attention on visual decision making. In this study, we show that measures of attention obtained from simultaneous EEG recordings can explain per-trial evidence accumulation rates and perceptual preprocessing times during a visual decision making task. Models assuming linear relationships between diffusion model parameters and EEG measures as external inputs were fit in a single step in a hierarchical Bayesian framework. The EEG measures were features of the evoked potential (EP) to the onset of a masking noise and the onset of a task-relevant signal stimulus. Single-trial evoked EEG responses, P200s to the onsets of visual noise and N200s to the onsets of visual signal, explain single-trial evidence accumulation and preprocessing times. Within-trial evidence accumulation variance was not found to be influenced by attention to the signal or noise. Single-trial measures of attention lead to better out-of-sample predictions of accuracy and correct reaction time distributions for individual subjects. PMID:28435173

  8. How attention influences perceptual decision making: Single-trial EEG correlates of drift-diffusion model parameters.

    PubMed

    Nunez, Michael D; Vandekerckhove, Joachim; Srinivasan, Ramesh

    2017-02-01

    Perceptual decision making can be accounted for by drift-diffusion models, a class of decision-making models that assume a stochastic accumulation of evidence on each trial. Fitting response time and accuracy to a drift-diffusion model produces evidence accumulation rate and non-decision time parameter estimates that reflect cognitive processes. Our goal is to elucidate the effect of attention on visual decision making. In this study, we show that measures of attention obtained from simultaneous EEG recordings can explain per-trial evidence accumulation rates and perceptual preprocessing times during a visual decision making task. Models assuming linear relationships between diffusion model parameters and EEG measures as external inputs were fit in a single step in a hierarchical Bayesian framework. The EEG measures were features of the evoked potential (EP) to the onset of a masking noise and the onset of a task-relevant signal stimulus. Single-trial evoked EEG responses, P200s to the onsets of visual noise and N200s to the onsets of visual signal, explain single-trial evidence accumulation and preprocessing times. Within-trial evidence accumulation variance was not found to be influenced by attention to the signal or noise. Single-trial measures of attention lead to better out-of-sample predictions of accuracy and correct reaction time distributions for individual subjects.

  9. Delineation of subsurface hydrocarbon contamination at a former hydrogenation plant using spectral induced polarization imaging

    NASA Astrophysics Data System (ADS)

    Flores Orozco, Adrián; Kemna, Andreas; Oberdörster, Christoph; Zschornack, Ludwig; Leven, Carsten; Dietrich, Peter; Weiss, Holger

    2012-08-01

    Broadband spectral induced polarization (SIP) measurements were conducted at a former hydrogenation plant in Zeitz (NE Germany) to investigate the potential of SIP imaging to delineate areas with different BTEX (benzene, toluene, ethylbenzene, and xylene) concentrations. Conductivity images reveal a poor correlation with the distribution of contaminants; whereas phase images exhibit two main anomalies: low phase shift values (< 5 mrad) for locations with high BTEX concentrations, including the occurrence of free-phase product (BTEX concentrations > 1.7 g/l), and higher phase values for lower BTEX concentrations. Moreover, the spectral response of the areas with high BTEX concentration and free-phase products reveals a flattened spectrum in the low frequencies (< 40 Hz), while areas with lower BTEX concentrations exhibit a response characterized by a frequency peak. The SIP response was modelled using a Debye decomposition to compute images of the median relaxation-time. Consistent with laboratory studies, we observed an increase in the relaxation-time associated with an increase in BTEX concentrations. Measurements were also collected in the time domain (TDIP), revealing imaging results consistent with those obtained for frequency domain (SIP) measurements. Results presented here demonstrate the potential of the SIP imaging method to discriminate source and plume of dissolved contaminants at BTEX contaminated sites.

  10. Aqueous solvation from the water perspective.

    PubMed

    Ahmed, Saima; Pasti, Andrea; Fernández-Terán, Ricardo J; Ciardi, Gustavo; Shalit, Andrey; Hamm, Peter

    2018-06-21

    The response of water re-solvating a charge-transfer dye (deprotonated Coumarin 343) after photoexcitation has been measured by means of transient THz spectroscopy. Two steps of increasing THz absorption are observed, a first ∼10 ps step on the time scale of Debye relaxation of bulk water and a much slower step on a 3.9 ns time scale, the latter of which reflecting heating of the bulk solution upon electronic relaxation of the dye molecules from the S 1 back into the S 0 state. As an additional reference experiment, the hydroxyl vibration of water has been excited directly by a short IR pulse, establishing that the THz signal measures an elevated temperature within ∼1 ps. This result shows that the first step upon dye excitation (10 ps) is not limited by the response time of the THz signal; it rather reflects the reorientation of water molecules in the solvation layer. The apparent discrepancy between the relatively slow reorientation time and the general notion that water is among the fastest solvents with a solvation time in the sub-picosecond regime is discussed. Furthermore, non-equilibrium molecular dynamics simulations have been performed, revealing a close-to-quantitative agreement with experiment, which allows one to disentangle the contribution of heating to the overall THz response from that of water orientation.

  11. A urine volume measurement system

    NASA Technical Reports Server (NTRS)

    Poppendiek, H. F.; Mouritzen, G.; Sabin, C. M.

    1972-01-01

    An improved urine volume measurement system for use in the unusual environment of manned space flight is reported. The system utilizes a low time-constant thermal flowmeter. The time integral of the transient response of the flowmeter gives the urine volume during a void as it occurs. In addition, the two phase flows through the flowmeter present no problem. Developments of the thermal flowmeter and a verification of the predicted performance characteristics are summarized.

  12. Determining Energy Distributions of HF-Accelerated Electrons at HAARP

    DTIC Science & Technology

    2015-11-18

    altitude satellites , altitude- resolved side-view optical measurements of artificial airglow emissions combined with full ISR measurements of electron...for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data...3. DATES COVERED. Indicate the time during which the work was performed and the report was written, e.g., Jun 1997 - Jun 1998; 1-10 Jun 1996; May

  13. Acute Stress Dysregulates the LPP ERP Response to Emotional Pictures and Impairs Sustained Attention: Time-Sensitive Effects

    PubMed Central

    Alomari, Rima A.; Fernandez, Mercedes; Banks, Jonathan B.; Acosta, Juliana; Tartar, Jaime L.

    2015-01-01

    Stress can increase emotional vigilance at the cost of a decrease in attention towards non-emotional stimuli. However, the time-dependent effects of acute stress on emotion processing are uncertain. We tested the effects of acute stress on subsequent emotion processing up to 40 min following an acute stressor. Our measure of emotion processing was the late positive potential (LPP) component of the visual event-related potential (ERP), and our measure of non-emotional attention was the sustained attention to response task (SART). We also measured cortisol levels before and after the socially evaluated cold pressor test (SECPT) induction. We found that the effects of stress on the LPP ERP emotion measure were time sensitive. Specifically, the LPP ERP was only altered in the late time-point (30–40 min post-stress) when cortisol was at its highest level. Here, the LPP no longer discriminated between the emotional and non-emotional picture categories, most likely because neutral pictures were perceived as emotional. Moreover, compared to the non-stress condition, the stress-condition showed impaired performance on the SART. Our results support the idea that a limit in attention resources after an emotional stressor is associated with the brain incorrectly processing non-emotional stimuli as emotional and interferes with sustained attention. PMID:26010485

  14. Measuring Sound-Processor Threshold Levels for Pediatric Cochlear Implant Recipients Using Conditioned Play Audiometry via Telepractice

    PubMed Central

    Goehring, Jenny L.

    2017-01-01

    Purpose This study evaluated the use of telepractice for measuring cochlear implant (CI) behavioral threshold (T) levels in children using conditioned play audiometry (CPA). The goals were to determine whether (a) T levels measured via telepractice were not significantly different from those obtained in person, (b) response probability differed between remote and in-person conditions, and (c) the remote visit required more time than the in-person condition. Method An ABBA design (A, in-person; B, remote) was split across 2 visits. Nineteen children aged 2.6–7.1 years participated. T levels were measured using CPA for 3 electrodes per session. A “hit” rate was calculated to determine whether the likelihood of obtaining responses differed between conditions. Test time was compared across conditions. A questionnaire was administered to assess parent/caregiver attitudes about telepractice. Results Results indicated no significant difference in T levels between conditions. Hit rates were not significantly different between in-person and remote conditions (98% vs. 97%, respectively). Test time was similar between conditions. Questionnaire results revealed that 100% of caregivers would use telepractice for CI appointments either some or all of the time. Conclusion Telepractice is a viable option for routine pediatric programming appointments for children using CPA to set behavioral thresholds. PMID:28257529

  15. Acute Stress Dysregulates the LPP ERP Response to Emotional Pictures and Impairs Sustained Attention: Time-Sensitive Effects.

    PubMed

    Alomari, Rima A; Fernandez, Mercedes; Banks, Jonathan B; Acosta, Juliana; Tartar, Jaime L

    2015-05-20

    Stress can increase emotional vigilance at the cost of a decrease in attention towards non-emotional stimuli. However, the time-dependent effects of acute stress on emotion processing are uncertain. We tested the effects of acute stress on subsequent emotion processing up to 40 min following an acute stressor. Our measure of emotion processing was the late positive potential (LPP) component of the visual event-related potential (ERP), and our measure of non-emotional attention was the sustained attention to response task (SART). We also measured cortisol levels before and after the socially evaluated cold pressor test (SECPT) induction. We found that the effects of stress on the LPP ERP emotion measure were time sensitive. Specifically, the LPP ERP was only altered in the late time-point (30-40 min post-stress) when cortisol was at its highest level. Here, the LPP no longer discriminated between the emotional and non-emotional picture categories, most likely because neutral pictures were perceived as emotional. Moreover, compared to the non-stress condition, the stress-condition showed impaired performance on the SART. Our results support the idea that a limit in attention resources after an emotional stressor is associated with the brain incorrectly processing non-emotional stimuli as emotional and interferes with sustained attention.

  16. Aircraft Fault Detection Using Real-Time Frequency Response Estimation

    NASA Technical Reports Server (NTRS)

    Grauer, Jared A.

    2016-01-01

    A real-time method for estimating time-varying aircraft frequency responses from input and output measurements was demonstrated. The Bat-4 subscale airplane was used with NASA Langley Research Center's AirSTAR unmanned aerial flight test facility to conduct flight tests and collect data for dynamic modeling. Orthogonal phase-optimized multisine inputs, summed with pilot stick and pedal inputs, were used to excite the responses. The aircraft was tested in its normal configuration and with emulated failures, which included a stuck left ruddervator and an increased command path latency. No prior knowledge of a dynamic model was used or available for the estimation. The longitudinal short period dynamics were investigated in this work. Time-varying frequency responses and stability margins were tracked well using a 20 second sliding window of data, as compared to a post-flight analysis using output error parameter estimation and a low-order equivalent system model. This method could be used in a real-time fault detection system, or for other applications of dynamic modeling such as real-time verification of stability margins during envelope expansion tests.

  17. Impact of cold climates on vehicle emissions: the cold start air toxics pulse : final report.

    DOT National Transportation Integrated Search

    2016-09-21

    This project measured cold start emissions from four vehicles in winter using fast response instrumentation to accurately measure the : time variation of the cold start emission pulse. Seventeen successful tests were conducted over a temperature rang...

  18. Characterizing viscoelastic mechanical properties of highly compliant polymers and biological tissues using impact indentation.

    PubMed

    Mijailovic, Aleksandar S; Qing, Bo; Fortunato, Daniel; Van Vliet, Krystyn J

    2018-04-15

    Precise and accurate measurement of viscoelastic mechanical properties becomes increasingly challenging as sample stiffness decreases to elastic moduli <1 kPa, largely due to difficulties detecting initial contact with the compliant sample surface. This limitation is particularly relevant to characterization of biological soft tissues and compliant gels. Here, we employ impact indentation which, in contrast to shear rheology and conventional indentation, does not require contact detection a priori, and present a novel method to extract viscoelastic moduli and relaxation time constants directly from the impact response. We first validate our approach by using both impact indentation and shear rheology to characterize polydimethylsiloxane (PDMS) elastomers of stiffness ranging from 100 s of Pa to nearly 10 kPa. Assuming a linear viscoelastic constitutive model for the material, we find that the moduli and relaxation times obtained from fitting the impact response agree well with those obtained from fitting the rheological response. Next, we demonstrate our validated method on hydrated, biological soft tissues obtained from porcine brain, murine liver, and murine heart, and report the equilibrium shear moduli, instantaneous shear moduli, and relaxation time constants for each tissue. Together, our findings provide a new and straightforward approach capable of probing local mechanical properties of highly compliant viscoelastic materials with millimeter scale spatial resolution, mitigating complications involving contact detection or sample geometric constraints. Characterization and optimization of mechanical properties can be essential for the proper function of biomaterials in diverse applications. However, precise and accurate measurement of viscoelastic mechanical properties becomes increasingly difficult with increased compliance (particularly for elastic moduli <1 kPa), largely due to challenges detecting initial contact with the compliant sample surface and measuring response at short timescale or high frequency. By contrast, impact indentation has highly accurate contact detection and can be used to measure short timescale (glassy) response. Here, we demonstrate an experimental and analytical method that confers significant advantages over existing approaches to extract spatially resolved viscoelastic moduli and characteristic time constants of biological tissues (e.g., brain and heart) and engineered biomaterials. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  19. Analysis of the time-varying energy of brain responses to an oddball paradigm using short-term smoothed Wigner-Ville distribution.

    PubMed

    Tağluk, M E; Cakmak, E D; Karakaş, S

    2005-04-30

    Cognitive brain responses to external stimuli, as measured by event related potentials (ERPs), have been analyzed from a variety of perspectives to investigate brain dynamics. Here, the brain responses of healthy subjects to auditory oddball paradigms, standard and deviant stimuli, recorded on an Fz electrode site were studied using a short-term version of the smoothed Wigner-Ville distribution (STSW) method. A smoothing kernel was designed to preserve the auto energy of the signal with maximum time and frequency resolutions. Analysis was conducted mainly on the time-frequency distributions (TFDs) of sweeps recorded during successive trials including the TFD of averaged single sweeps as the evoked time-frequency (ETF) brain response and the average of TFDs of single sweeps as the time-frequency (TF) brain response. Also the power entropy and the phase angles of the signal at frequency f and time t locked to the stimulus onset were studied across single trials as the TF power-locked and the TF phase-locked brain responses, respectively. TFDs represented in this way demonstrated the ERP spectro-temporal characteristics from multiple perspectives. The time-varying energy of the individual components manifested interesting TF structures in the form of amplitude modulated (AM) and frequency modulated (FM) energy bursts. The TF power-locked and phase-locked brain responses provoked ERP energies in a manner modulated by cognitive functions, an observation requiring further investigation. These results may lead to a better understanding of integrative brain dynamics.

  20. Fully-reversible optical sensor for hydrogen peroxide with fast response.

    PubMed

    Ding, Longjiang; Chen, Siyu; Zhang, Wei; Zhang, Yinglu; Wang, Xu-Dong

    2018-05-09

    A fully reversible optical sensor for hydrogen peroxide with fast response is presented. The sensor was fabricated by in-situ growing ultra-small platinum nanoparticles (PtNPs) inside the pores of fibrous silica particles (KCC-1). The nanocomposite was then embedded into a hydrogel matrix and form a sensor layer, the immobilized PtNPs can catalytically convert hydrogen peroxide into molecular oxygen, which is measured via luminescent quenching based oxygen sensor underneath. Owing to the high porosity and permeability of KCC-1 and high local concentration of PtNPs, the sensor exhibits fast response (less than 1 min) and full reversibility. The measurement range of the sensor covers 1.0 μM to 10.0 mM, and very small amount of sample is required during measurement (200 μL). Because of its high stability, excellent reversibility and selectivity, and extremely fast response, the sensor could fulfill all industry requirements for real-time measurement, and fill market vacancy.

  1. Simulation of Thermographic Responses of Delaminations in Composites with Quadrupole Method

    NASA Technical Reports Server (NTRS)

    Winfree, William P.; Zalameda, Joseph N.; Howell, Patricia A.; Cramer, K. Elliott

    2016-01-01

    The application of the quadrupole method for simulating thermal responses of delaminations in carbon fiber reinforced epoxy composites materials is presented. The method solves for the flux at the interface containing the delamination. From the interface flux, the temperature at the surface is calculated. While the results presented are for single sided measurements, with ash heating, expansion of the technique to arbitrary temporal flux heating or through transmission measurements is simple. The quadrupole method is shown to have two distinct advantages relative to finite element or finite difference techniques. First, it is straight forward to incorporate arbitrary shaped delaminations into the simulation. Second, the quadrupole method enables calculation of the thermal response at only the times of interest. This, combined with a significant reduction in the number of degrees of freedom for the same simulation quality, results in a reduction of the computation time by at least an order of magnitude. Therefore, it is a more viable technique for model based inversion of thermographic data. Results for simulations of delaminations in composites are presented and compared to measurements and finite element method results.

  2. Evaluation of early bone response to fluoride-modified and anodically oxidized titanium implants through continuous removal torque analysis.

    PubMed

    Kwon, Taek-Ka; Lee, Hyo-Jung; Min, Seung-Ki; Yeo, In-Sung

    2012-10-01

    To compare between a bioactive and a bioinert implant with different geometries by continuous measurement of the removal torque and calculation of the angular momentum of each surfaced implant. Six New Zealand white rabbits were used in the study. Each rabbit received 2 implants. A bioactive fluoride-modified implant with a conical connection and microthread design was inserted into one tibia, and a bioinert anodically oxidized implant with an external connection design was inserted into the other. After 2 weeks of implant insertion, the removal torque values were continuously measured according to time. Using the time-torque curve resulting from the measurements, the maximum values were determined, and the angular momenta were calculated. The anodically oxidized implant had significantly higher peak removal torque and angular momentum values than the fluoride-modified implant (P < 0.05). The impact of the fluoride-modified bioactive implant on early bone response remains unclear. Considering the angular momentum of dental implants may assist in the elucidation of the effect of implant geometry on bone response.

  3. High-precision measurement of the light response of BC-418 plastic scintillator to protons with energies from 100 keV to 10 MeV

    NASA Astrophysics Data System (ADS)

    Henzl, Vladimir; Daub, Brian; French, Jennifer; Matthews, June; Kovash, Michael; Wender, Stephen; Famiano, Michael; Koehler, Katrina; Yuly, Mark

    2010-11-01

    The determination of the light response of many organic scintillators to various types of radiation has been a subject of numerous experimental as well as theoretical studies in the past. But while the data on light response to particles with energies above 1 MeV are precise and abundant, the information on light response to very low energy particles (i.e. below 1 MeV) is scarce or completely missing. In this study we measured the light response of a BC-418 scintillator to protons with energies from 100 keV to 10 MeV. The experiment was performed at Weapons Neutron Research Facility at LANSCE, Los Alamos. The neutron beam from a spallation source is used to irradiate the active target made from BC-418 plastic scintillator. The recoiled protons detected in the active target are measured in coincidence with elastically scattered incident neutrons detected by and adjacent liquid scintillator. Time of flight of the incident neutron and the knowledge of scattering geometry allow for a kinematically complete and high-precision measurement of the light response as a function of the proton energy.

  4. Sensing the heat stress by Mammalian cells.

    PubMed

    Cates, Jordan; Graham, Garrett C; Omattage, Natalie; Pavesich, Elizabeth; Setliff, Ian; Shaw, Jack; Smith, Caitlin Lee; Lipan, Ovidiu

    2011-08-11

    The heat-shock response network controls the adaptation and survival of the cell against environmental stress. This network is highly conserved and is connected with many other signaling pathways. A key element of the heat-shock network is the heat-shock transcription factor-1 (HSF), which is transiently activated by elevated temperatures. HSF translocates to the nucleus upon elevated temperatures, forming homotrimeric complexes. The HSF homotrimers bind to the heat shock element on the DNA and control the expression of the hsp70 gene. The Hsp70 proteins protect cells from thermal stress. Thermal stress causes the unfolding of proteins, perturbing thus the pathways under their control. By binding to these proteins, Hsp70 allows them to refold and prevents their aggregation. The modulation of the activity of the hsp70-promoter by the intensity of the input stress is thus critical for cell's survival. The promoter activity starts from a basal level and rapidly increases once the stress is applied, reaches a maximum level and attenuates slowely back to the basal level. This phenomenon is the hallmark of many experimental studies and of all computational network analysis. The molecular construct used as a measure of the response to thermal stress is a Hsp70-GFP fusion gene transfected in Chinese hamster ovary (CHO) cells. The time profile of the GFP protein depends on the transient activity, Transient(t), of the heat shock system. The function Transient(t) depends on hsp70 promoter activity, transcriptional regulation and the translation initiation effects elicited by the heat stress. The GFP time profile is recorded using flow cytometry measurements, a technique that allows a quantitative measurement of the fluorescence of a large number of cells (104). The GFP responses to one and two heat shocks were measured for 261 conditions of different temperatures and durations. We found that: (i) the response of the cell to two consecutive shocks (i.e., no recovery time in between shocks) depends on the order of the input shocks, that is the shocks do not commute; (ii) the responses may be classified as mild or severe, depending on the temperature level and the duration of the heat shock and (iii) the response is highly sensitive to small variations in temperature. We propose a mathematical model that maps temperature into the transient activity using experimental data that describes the time course of the response to input thermal stress. The model is built on thermotolerance without recovery time, sharp sensitivity to small variations in temperature and the existence of mild and severe classes of stress responses. The theoretical predictions are tested against experimental data using a series of double-shock inputs. The theoretical structure is represented by a sequence of three cascade processes that transform the input stress into the transient activity. The structure of the cascade is nonlinear-linear-nonlinear (NLN). The first nonlinear system (N) from the NLN structure represents the amplification of small changes in the environmental temperature; the linear system (L) represents the thermotolerance without recovery time, whereas the last system (N) represents the transition of the cell's response from a mild to a severe shock.

  5. High responsivity secondary ion energy analyzer

    NASA Astrophysics Data System (ADS)

    Belov, A. S.; Chermoshentsev, D. A.; Gavrilov, S. A.; Frolov, O. T.; Netchaeva, L. P.; Nikulin, E. S.; Zubets, V. N.

    2018-05-01

    The degree of space charge compensation of a 70 mA, 400 keV pulsed hydrogen ion beam has been measured with the use of an electrostatic energy analyzer of secondary ions. The large azimuthal angle of the analyzer enables a high responsivity, defined as the ratio of the slow secondary ion current emerging from the partially-compensated ion beam to the fast ion beam current. We measured 84% space charge compensation of the ion beam. The current from the slow ions and the rise time from the degree of space charge compensation were measured and compared with expected values.

  6. Behavioural benefits of multisensory processing in ferrets.

    PubMed

    Hammond-Kenny, Amy; Bajo, Victoria M; King, Andrew J; Nodal, Fernando R

    2017-01-01

    Enhanced detection and discrimination, along with faster reaction times, are the most typical behavioural manifestations of the brain's capacity to integrate multisensory signals arising from the same object. In this study, we examined whether multisensory behavioural gains are observable across different components of the localization response that are potentially under the command of distinct brain regions. We measured the ability of ferrets to localize unisensory (auditory or visual) and spatiotemporally coincident auditory-visual stimuli of different durations that were presented from one of seven locations spanning the frontal hemifield. During the localization task, we recorded the head movements made following stimulus presentation, as a metric for assessing the initial orienting response of the ferrets, as well as the subsequent choice of which target location to approach to receive a reward. Head-orienting responses to auditory-visual stimuli were more accurate and faster than those made to visual but not auditory targets, suggesting that these movements were guided principally by sound alone. In contrast, approach-to-target localization responses were more accurate and faster to spatially congruent auditory-visual stimuli throughout the frontal hemifield than to either visual or auditory stimuli alone. Race model inequality analysis of head-orienting reaction times and approach-to-target response times indicates that different processes, probability summation and neural integration, respectively, are likely to be responsible for the effects of multisensory stimulation on these two measures of localization behaviour. © 2016 The Authors. European Journal of Neuroscience published by Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  7. Higher energy prices are associated with diminished resources, performance and safety in Australian ambulance systems.

    PubMed

    Brown, Lawrence H; Chaiechi, Taha; Buettner, Petra G; Canyon, Deon V; Crawford, J Mac; Judd, Jenni

    2013-02-01

    To evaluate the impact of changing energy prices on Australian ambulance systems. Generalised estimating equations were used to analyse contemporaneous and lagged relationships between changes in energy prices and ambulance system performance measures in all Australian State/Territory ambulance systems for the years 2000-2010. Measures included: expenditures per response; labour-to-total expenditure ratio; full-time equivalent employees (FTE) per 10,000 responses; average salary; median and 90th percentile response time; and injury compensation claims. Energy price data included State average diesel price, State average electricity price, and world crude oil price. Changes in diesel prices were inversely associated with changes in salaries, and positively associated with changes in ambulance response times; changes in oil prices were also inversely associated with changes in salaries, as well with staffing levels and expenditures per ambulance response. Changes in electricity prices were positively associated with changes in expenditures per response and changes in salaries; they were also positively associated with changes in injury compensation claims per 100 FTE. Changes in energy prices are associated with changes in Australian ambulance systems' resource, performance and safety characteristics in ways that could affect both patients and personnel. Further research is needed to explore the mechanisms of, and strategies for mitigating, these impacts. The impacts of energy prices on other aspects of the health system should also be investigated. © 2013 The Authors. ANZJPH © 2013 Public Health Association of Australia.

  8. Evaluation of a fast single-photon avalanche photodiode for measurement of early transmitted photons through diffusive media.

    PubMed

    Mu, Ying; Valim, Niksa; Niedre, Mark

    2013-06-15

    We tested the performance of a fast single-photon avalanche photodiode (SPAD) in measurement of early transmitted photons through diffusive media. In combination with a femtosecond titanium:sapphire laser, the overall instrument temporal response time was 59 ps. Using two experimental models, we showed that the SPAD allowed measurement of photon-density sensitivity functions that were approximately 65% narrower than the ungated continuous wave case at very early times. This exceeds the performance that we have previously achieved with photomultiplier-tube-based systems and approaches the theoretical maximum predicted by time-resolved Monte Carlo simulations.

  9. Conceptual question response times in Peer Instruction classrooms

    NASA Astrophysics Data System (ADS)

    Miller, Kelly; Lasry, Nathaniel; Lukoff, Brian; Schell, Julie; Mazur, Eric

    2014-12-01

    Classroom response systems are widely used in interactive teaching environments as a way to engage students by asking them questions. Previous research on the time taken by students to respond to conceptual questions has yielded insights on how students think and change conceptions. We measure the amount of time students take to respond to in-class, conceptual questions [ConcepTests (CTs)] in two introductory physics courses taught using Peer Instruction and use item response theory to determine the difficulty of the CTs. We examine response time differences between correct and incorrect answers both before and after the peer discussion for CTs of varying difficulty. We also determine the relationship between response time and student performance on a standardized test of incoming physics knowledge, precourse self-efficacy, and gender. Our data reveal three results of interest. First, response time for correct answers is significantly faster than for incorrect answers, both before and after peer discussion, especially for easy CTs. Second, students with greater incoming physics knowledge and higher self-efficacy respond faster in both rounds. Third, there is no gender difference in response rate after controlling for incoming physics knowledge scores, although males register significantly more attempts before committing to a final answer than do female students. These results provide insight into effective CT pacing during Peer Instruction. In particular, in order to maintain a pace that keeps everyone engaged, students should not be given too much time to respond. When around 80% of the answers are in, the ratio of correct to incorrect responses rapidly approaches levels indicating random guessing and instructors should close the poll.

  10. Model for Correlating Real-Time Survey Results to Contaminant Concentrations - 12183

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Walker, Stuart A.

    2012-07-01

    The U.S. Environmental Protection Agency (EPA) Superfund program is developing a new Counts Per Minute (CPM) calculator to correlate real-time survey results, which are often expressed as counts per minute, to contaminant concentrations that are more typically provided in risk assessments or for cleanup levels, usually expressed in pCi/g or pCi/m{sup 2}. Currently there is no EPA guidance for Superfund sites on correlating count per minute field survey readings back to risk, dose, or other ARAR based concentrations. The CPM calculator is a web-based model that estimates a gamma detector response for a given level of contamination. The intent ofmore » the CPM calculator is to facilitate more real-time measurements within a Superfund response framework. The draft of the CPM calculator is still undergoing internal EPA review. This will be followed by external peer review. It is expected that the CPM calculator will at least be in peer review by the time of WM2012 and possibly finalized at that time. The CPM calculator should facilitate greater use of real-time measurement at Superfund sites. The CPM calculator may also standardize the process of converting lab data to real time measurements. It will thus lessen the amount of lab sampling that is needed for site characterization and confirmation surveys, but it will not remove the need for sampling. (authors)« less

  11. In-depth study of single photon time resolution for the Philips digital silicon photomultiplier

    NASA Astrophysics Data System (ADS)

    Liu, Z.; Gundacker, S.; Pizzichemi, M.; Ghezzi, A.; Auffray, E.; Lecoq, P.; Paganoni, M.

    2016-06-01

    The digital silicon photomultiplier (SiPM) has been commercialised by Philips as an innovative technology compared to analog silicon photomultiplier devices. The Philips digital SiPM, has a pair of time to digital converters (TDCs) connected to 12800 single photon avalanche diodes (SPADs). Detailed measurements were performed to understand the low photon time response of the Philips digital SiPM. The single photon time resolution (SPTR) of every single SPAD in a pixel consisting of 3200 SPADs was measured and an average value of 85 ps full width at half maximum (FWHM) was observed. Each SPAD sends the signal to the TDC with different signal propagation time, resulting in a so called trigger network skew. This distribution of the trigger network skew for a pixel (3200 SPADs) has been measured and a variation of 50 ps FWHM was extracted. The SPTR of the whole pixel is the combination of SPAD jitter, trigger network skew, and the SPAD non-uniformity. The SPTR of a complete pixel was 103 ps FWHM at 3.3 V above breakdown voltage. Further, the effect of the crosstalk at a low photon level has been studied, with the two photon time resolution degrading if the events are a combination of detected (true) photons and crosstalk events. Finally, the time response to multiple photons was investigated.

  12. Stability and Change in Posttraumatic Distress: A 7-Year Follow-Up Study of Mothers and Young Children Exposed to Cumulative Trauma.

    PubMed

    Pat-Horenczyk, Ruth; Cohen, Sarale; Ziv, Yuval; Achituv, M; Brickman, Sophie; Blanchard, Tamar; Brom, Danny

    2017-04-01

    In situations of cumulative trauma, it is often unclear why some people remain resilient, whereas others experience distress, and how likely these responses are to change over time. To investigate the constancy of responses to cumulative trauma, stability and change in posttraumatic distress and resistance (as defined by no evidence of clinical symptoms) were assessed twice in 140 Israeli children and mothers exposed to continual rocket attacks over approximately 7 years, when the children were 2-4 (Time 1) and 9-11 years of age (Time 2). Measures included trauma exposure, posttraumatic and depressive symptoms, and child behavioral problems. We identified 4 longitudinal courses (LCs): resilient (resistance at Time 1 and Time 2), recovered (clinical distress at Time 1 and resistance at Time 2), developed symptoms (resistance at Time 1 and clinical distress at Time 2), and chronic distress (clinical distress at Time 1 and Time 2). Results showed more stability than change in the frequencies of resistance at both times of measurement. The resilient LC was the most common longitudinal course for both mothers and children. Multinomial regression models indicated that maternal posttraumatic symptoms predicted the recovered and chronic distress LCs of the children. Copyright © 2017 International Society for Traumatic Stress Studies.

  13. The effect of orientation difference in fused deposition modeling of ABS polymer on the processing time, dimension accuracy, and strength

    NASA Astrophysics Data System (ADS)

    Tanoto, Yopi Y.; Anggono, Juliana; Siahaan, Ian H.; Budiman, Wesley

    2017-01-01

    There are several parameters that must be set before manufacturing a product using 3D printing. These parameters include the orientation deposition of that product, type of material, form fill, fill density, and other parameters. The finished product of 3D printing has some responses that can be observed, measured, and tested. Some of those responses are the processing time, the dimensions of the end product, its surface roughness and the mechanical properties, i.e. its yield strength, ultimate tensile strength, and impact resistance. This research was conducted to study the relationship between process parameters of 3D printing machine using a technology of fused deposition modeling (FDM) and the generated responses. The material used was ABS plastic that was commonly used in the industry. Understanding the relationship between the parameters and the responses thus the resulting product can be manufactured to meet the user needs. Three different orientations in depositing the ABS polymer named XY(first orientation), YX (second orientation), and ZX (third orientation) were studied. Processing time, dimensional accuracy, and the product strength were the responses that were measured and tested. The study reports that the printing process with third orientation was the fastest printing process with the processing time 2432 seconds followed by orientation 1 and 2 with a processing time of 2688 and 2780 seconds respectively. Dimension accuracy was also measured from the width and the length of gauge area of tensile test specimens printed in comparison with the dimensions required by ASTM 638-02. It was found that the smallest difference was in thickness dimension, i.e. 0.1 mm thicker in printed sample using second orientation than as required by the standard. The smallest thickness deviation from the standard was measured in width dimension of a sample printed using first orientation (0.13 mm). As with the length dimension, the closest dimension to the standard was resulted from the third orientation product, i.e 0.2 mm. Tensile test done on all the specimens produced with those three orientations shows that the highest tensile strength was obtained in sample from second orientation deposition, i.e. 7.66 MPa followed by the first and third orientations products, i.e. 6.8 MPa and 3.31 MPa, respectively.

  14. Fast response liquid crystal devices

    NASA Astrophysics Data System (ADS)

    Wu, Yung-Hsun

    Liquid crystal (LC) has been widely used for displays, spatial light modulators, variable optical attenuators (VOAs) and other tunable photonic devices. The response time of these devices is mainly determined by the employed liquid crystal material. The response time of a LC device depends on the visco-elastic coefficient (gamma1/K11), LC cell gap (d), and applied voltage. Hence, low visco-elastic coefficient LC materials and thinner cell gap are favorable for reducing the response time. However, low visco-elastic coefficient LCs are usually associated with a low birefringence because of shorter molecular conjugation. For display applications, such as LCD TVs, low birefringence (Deltan<0.1) LCs are commonly used. However, for optical communications at 1550 nm, low birefringence requires to a thick cell gap which, in turn, increases the response time. How to obtain fast response for the LC devices is a fundamentally important and technically challenging task. In this dissertation, we investigate several methods to improve liquid crystal response time, for examples, using dual-frequency liquid crystals, polymer stabilized liquid crystals, and sheared polymer network liquid crystals. We discover a new class of material, denoted as sheared polymer network liquid crystal (SPNLC) which exhibits a submillisecond response time. Moreover, this response time is insensitive to the LC cell gap. This is the first LC device exhibiting such an interesting property. Chapters 1 and 2 describe the motivation and background of this dissertation. From chapter 3 to chapter 6, dual-frequency liquid crystals and polymer network methods are demonstrated as examples for the variable optical attenuators. Variable optical attenuator (VOA) is a key component in optical communications. Especially, the sheared PNLC VOA shows the best result; its dynamic range reaches 43 dB while the response time is in the submillisecond range at 1550 nm wavelength, which is 50 times faster than the commercial LC-based VOA. In Chapter 7, we report a new device called axially-symmetric sheared polymer network liquid crystals (AS-SPNLC) and use it as LC devices. Through analyzing the structure of this axially-symmetric SPNLC, we construct a 3-D model to explain the observed phenomena. An axially-symmetric sheared polymer network liquid crystal has several attractive features: (1) it is polarization independent, (2) it has gradient phase change, and (3) its response time is fast. It can be used for polarization converter and divergent LC lens. In addition, a new method for simultaneously measuring the phase retardation and optic axis of a compensation film is demonstrated using an axially-symmetric sheared polymer network liquid crystal. By overlaying a tested compensation film with a calibrated SPNLC cell between crossed polarizers, the optic axis and phase retardation value of the compensation film can be determined. This simple technique can be used for simultaneously measuring the optic axis and phase retardations of both A- and C-plates. These compensation films have been used extensively in wide-view LCD industry. Therefore, this method will make an important impact to the LCD industry.

  15. High-Frequency Response of the Atmospheric Electric Potential Gradient Under Strong and Dry Boundary-Layer Convection

    NASA Astrophysics Data System (ADS)

    Conceição, Ricardo; Silva, Hugo Gonçalves; Bennett, Alec; Salgado, Rui; Bortoli, Daniele; Costa, Maria João; Collares Pereira, Manuel

    2018-01-01

    The spectral response of atmospheric electric potential gradient gives important information about phenomena affecting this gradient at characteristic time scales ranging from years (e.g., solar modulation) to fractions of a second (e.g., turbulence). While long-term time scales have been exhaustively explored, short-term scales have received less attention. At such frequencies, space-charge transport inside the planetary boundary layer becomes a sizeable contribution to the potential gradient variability. For the first time, co-located (Évora, Portugal) measurements of boundary-layer backscatter profiles and the 100-Hz potential gradient are reported. Five campaign days are analyzed, providing evidence for a relation between high-frequency response of the potential gradient and strong dry convection.

  16. Nonlinear finite element model updating for damage identification of civil structures using batch Bayesian estimation

    NASA Astrophysics Data System (ADS)

    Ebrahimian, Hamed; Astroza, Rodrigo; Conte, Joel P.; de Callafon, Raymond A.

    2017-02-01

    This paper presents a framework for structural health monitoring (SHM) and damage identification of civil structures. This framework integrates advanced mechanics-based nonlinear finite element (FE) modeling and analysis techniques with a batch Bayesian estimation approach to estimate time-invariant model parameters used in the FE model of the structure of interest. The framework uses input excitation and dynamic response of the structure and updates a nonlinear FE model of the structure to minimize the discrepancies between predicted and measured response time histories. The updated FE model can then be interrogated to detect, localize, classify, and quantify the state of damage and predict the remaining useful life of the structure. As opposed to recursive estimation methods, in the batch Bayesian estimation approach, the entire time history of the input excitation and output response of the structure are used as a batch of data to estimate the FE model parameters through a number of iterations. In the case of non-informative prior, the batch Bayesian method leads to an extended maximum likelihood (ML) estimation method to estimate jointly time-invariant model parameters and the measurement noise amplitude. The extended ML estimation problem is solved efficiently using a gradient-based interior-point optimization algorithm. Gradient-based optimization algorithms require the FE response sensitivities with respect to the model parameters to be identified. The FE response sensitivities are computed accurately and efficiently using the direct differentiation method (DDM). The estimation uncertainties are evaluated based on the Cramer-Rao lower bound (CRLB) theorem by computing the exact Fisher Information matrix using the FE response sensitivities with respect to the model parameters. The accuracy of the proposed uncertainty quantification approach is verified using a sampling approach based on the unscented transformation. Two validation studies, based on realistic structural FE models of a bridge pier and a moment resisting steel frame, are performed to validate the performance and accuracy of the presented nonlinear FE model updating approach and demonstrate its application to SHM. These validation studies show the excellent performance of the proposed framework for SHM and damage identification even in the presence of high measurement noise and/or way-out initial estimates of the model parameters. Furthermore, the detrimental effects of the input measurement noise on the performance of the proposed framework are illustrated and quantified through one of the validation studies.

  17. F45. THE EFFICACY AND SAFETY OF BLONASERIN AFTER SWITCHING FROM OTHER ATYPICAL ANTIPSYCHOTICS IN SCHIZOPHRENIC INPATIENTS: AN OPEN-LABEL, MULTI-CENTER TRIAL

    PubMed Central

    Yoon, Bo-Hyun; Bahk, Won-Myong; Kwon, Young Joon; Lee, Sang-Yeol; Lee, Kwanghun; Kim, Moon Doo; Park, Sung-Yong; Song, Min-Kyu

    2018-01-01

    Abstract Background The aim of this study was to investigate the efficacy and safety of blonanserin treatment after switching from other atypical antipsychotics in schizophrenic inpatients who showed inadequate efficacy and poor tolerability. Methods A total of 63 schizophrenic inpatients (inadequate response group=45 and poor tolerability group=18) were included in this study. They were already treated with atypical antipsychotics except blonanserin and not favored due to inadequate responses or intolerable adverse effects. Blonanserin was administered during 12 weeks after switching from their previous antispsychotics. Treatment response was evaluated with Brief Psychiatric Rating Scale (BPRS) and CGI-S, and safety profile were measured with Abnormal Involuntary Movement Scale (AIMS), Simpson-Angus Extrapyramidal Side effects Scale (SAR)S and Barnes Akathisia Rating Scale (BARS). Drug Attitude Inventory (DAI-10) and Subjective Well-being Under Neuroleptic Treatment (SWN) were used for subjective estimates. Assessments were done at baseline, 1, 2, 4, 8 and 12 weeks after blonanserin treatment. Repeated measures of ANOVA were done to analyze the group (inadequate vs. intolerable group) and time effects. Results CGI and BPRS were showed significant treatment responses after switching to Blonaserin. Time effects were significant at 2, 4, 8, 12 weeks after switching and group by time effect were also significant at that time. Mean changes of AIMS, SARS and BARS scores were not significant throughout test trial. Although SWN was significantly improved after switching to Blonaserin, it was not found significant group by time effect. Discussion The results suggest that blonanserin may be effective and well tolerable in schizophrenic patients who showed inadequate treatment response or poor tolerability.

  18. Thermal performance curves, phenotypic plasticity, and the time scales of temperature exposure.

    PubMed

    Schulte, Patricia M; Healy, Timothy M; Fangue, Nann A

    2011-11-01

    Thermal performance curves (TPCs) describe the effects of temperature on biological rate processes. Here, we use examples from our work on common killifish (Fundulus heteroclitus) to illustrate some important conceptual issues relating to TPCs in the context of using these curves to predict the responses of organisms to climate change. Phenotypic plasticity has the capacity to alter the shape and position of the TPCs for acute exposures, but these changes can be obscured when rate processes are measured only following chronic exposures. For example, the acute TPC for mitochondrial respiration in killifish is exponential in shape, but this shape changes with acclimation. If respiration rate is measured only at the acclimation temperature, the TPC is linear, concealing the underlying mechanistic complexity at an acute time scale. These issues are particularly problematic when attempting to use TPCs to predict the responses of organisms to temperature change in natural environments. Many TPCs are generated using laboratory exposures to constant temperatures, but temperature fluctuates in the natural environment, and the mechanisms influencing performance at acute and chronic time scales, and the responses of the performance traits at these time scales may be quite different. Unfortunately, our current understanding of the mechanisms underlying the responses of organisms to temperature change is incomplete, particularly with respect to integrating from processes occurring at the level of single proteins up to whole-organism functions across different time scales, which is a challenge for the development of strongly grounded mechanistic models of responses to global climate change. © The Author 2011. Published by Oxford University Press on behalf of the Society for Integrative and Comparative Biology. All rights reserved.

  19. Accounting for inter-annual and seasonal variability in regionalization of hydrologic response in the Great Lakes basin

    NASA Astrophysics Data System (ADS)

    Kult, J. M.; Fry, L. M.; Gronewold, A. D.

    2012-12-01

    Methods for predicting streamflow in areas with limited or nonexistent measures of hydrologic response typically invoke the concept of regionalization, whereby knowledge pertaining to gauged catchments is transferred to ungauged catchments. In this study, we identify watershed physical characteristics acting as primary drivers of hydrologic response throughout the US portion of the Great Lakes basin. Relationships between watershed physical characteristics and hydrologic response are generated from 166 catchments spanning a variety of climate, soil, land cover, and land form regimes through regression tree analysis, leading to a grouping of watersheds exhibiting similar hydrologic response characteristics. These groupings are then used to predict response in ungauged watersheds in an uncertainty framework. Results from this method are assessed alongside one historical regionalization approach which, while simple, has served as a cornerstone of Great Lakes regional hydrologic research for several decades. Our approach expands upon previous research by considering multiple temporal characterizations of hydrologic response. Due to the substantial inter-annual and seasonal variability in hydrologic response observed over the Great Lakes basin, results from the regression tree analysis differ considerably depending on the level of temporal aggregation used to define the response. Specifically, higher levels of temporal aggregation for the response metric (for example, indices derived from long-term means of climate and streamflow observations) lead to improved watershed groupings with lower within-group variance. However, this perceived improvement in model skill occurs at the cost of understated uncertainty when applying the regression to time series simulations or as a basis for model calibration. In such cases, our results indicate that predictions based on long-term characterizations of hydrologic response can produce misleading conclusions when applied at shorter time steps. This study suggests that measures of hydrologic response quantified at these shorter time steps may provide a more robust basis for making predictions in applications of water resource management, model calibration and simulations, and human health and safety.

  20. Cognitive-Behavioral Therapy for Children With Functional Abdominal Pain and Their Parents Decreases Pain and Other Symptoms

    PubMed Central

    Levy, Rona L.; Langer, Shelby L.; Walker, Lynn S.; Romano, Joan M.; Christie, Dennis L.; Youssef, Nader; DuPen, Melissa M.; Feld, Andrew D.; Ballard, Sheri A.; Welsh, Ericka M.; Jeffery, Robert W.; Young, Melissa; Coffey, Melissa J.; Whitehead, William E.

    2011-01-01

    OBJECTIVES Unexplained abdominal pain in children has been shown to be related to parental responses to symptoms. This randomized controlled trial tested the efficacy of an intervention designed to improve outcomes in idiopathic childhood abdominal pain by altering parental responses to pain and children's ways of coping and thinking about their symptoms. METHODS Two hundred children with persistent functional abdominal pain and their parents were randomly assigned to one of two conditions—a three-session intervention of cognitive-behavioral treatment targeting parents' responses to their children's pain complaints and children's coping responses, or a three-session educational intervention that controlled for time and attention. Parents and children were assessed at pretreatment, and 1 week, 3 months, and 6 months post-treatment. Outcome measures were child and parent reports of child pain levels, function, and adjustment. Process measures included parental protective responses to children's symptom reports and child coping methods. RESULTS Children in the cognitive-behavioral condition showed greater baseline to follow-up decreases in pain and gastrointestinal symptom severity (as reported by parents) than children in the comparison condition (time × treatment interaction, P < 0.01). Also, parents in the cognitive-behavioral condition reported greater decreases in solicitous responses to their child's symptoms compared with parents in the comparison condition (time × treatment interaction, P < 0.0001). CONCLUSIONS An intervention aimed at reducing protective parental responses and increasing child coping skills is effective in reducing children's pain and symptom levels compared with an educational control condition. PMID:20216531

  1. Preferred modes in jets: comparison between different measures of the receptivity

    NASA Astrophysics Data System (ADS)

    Garnaud, Xavier; Lesshafft, Lutz; Schmid, Peter J.; Huerre, Patrick

    2012-11-01

    The response of jets to frequency forcing is usually measured experimentally in terms of the maximum amplitude of velocity fluctuations reached along the axis (Crow & Champagne (1971)). In the present work, the preferred mode of isothermal jets is discussed in terms of the linear flow response to time-harmonic forcing (Trefethen et al. (1993)). The optimal frequency response is computed for different choices of the objective functional: the usual energy (L2) norm and the maximum amplitude over the entire domain (L∞ norm). The relevance and limitations of the different objective functionals are critically analyzed. Although the dominant flow structures are robustly identified in all cases, the measure of the flow response in terms of the maximum amplitude does not suffer from the continually slow axial growth of low frequency perturbations. The financial support of the EADS Foundation is gratefully acknowledged.

  2. Recovery of photoinduced reversible dark States utilized for molecular diffusion measurements.

    PubMed

    Chmyrov, Andriy; Sandén, Tor; Widengren, Jerker

    2010-12-15

    For a spatially restricted excitation volume, the effective modulation of the excitation in time is influenced by the passage times of the molecules through the excitation volume. By applying an additional time-modulated excitation, the buildup of photoinduced reversible dark states in fluorescent molecules can be made to vary significantly with their passage times through the excitation volume. The variations in the dark state populations are reflected by the time-averaged fluorescence intensity, which thus can be used to characterize the mobilities of the molecules. The concept was experimentally verified by measuring the fluorescence response of freely diffusing cyanine fluorophores (Cy5), undergoing trans-cis isomerization when subject to time-modulated excitation in a focused laser beam. From the fluorescence response, and by applying a simple photodynamic model, the transition times of the Cy5 molecules could be well reproduced when applying different laminar flow speeds through the detection volume. The presented approach puts no constraints on sample concentration, no requirements for high time resolution or sensitivity in the detection, nor requires a high fluorescence brightness of the characterized molecules. This can make the concept useful for a broad range of biomolecular mobility studies.

  3. Fast-timing Capabilities of Silicon Sensors for the CMS High-Granularity Calorimeter at the High-Luminosity LHC

    NASA Astrophysics Data System (ADS)

    Akchurin, Nural; CMS Collaboration

    2017-11-01

    We report on the signal timing capabilities of thin silicon sensors when traversed by multiple simultaneous minimum ionizing particles (MIP). Three different planar sensors, 133, 211, and 285 μm thick in depletion thickness, have been exposed to high energy muons and electrons at CERN. We describe signal shape and timing resolution measurements as well as the response of these devices as a function of the multiplicity of MIPs. We compare these measurements to simulations where possible. We achieve better than 20 ps timing resolution for signals larger than a few tens of MIPs.

  4. Effects of Phonation Time and Magnitude Dose on Vocal Fold Epithelial Genes, Barrier Integrity, and Function

    PubMed Central

    Kojima, Tsuyoshi; Valenzuela, Carla V.; Novaleski, Carolyn K.; Van Deusen, Mark; Mitchell, Joshua R.; Garrett, C. Gaelyn; Sivasankar, M. Preeti; Rousseau, Bernard

    2014-01-01

    Objective To investigate the effects of increasing time and magnitude doses of vibration exposure on transcription of the vocal fold's junctional proteins, structural alterations, and functional tissue outcomes. Study Design Animal study. Methods 100 New Zealand White breeder rabbits were studied. Dependent variables were measured in response to increasing time doses (30, 60, or 120 minutes) and magnitude doses (control, modal intensity, and raised intensity) of vibration exposure. Messenger RNA expression of occludin, zonula occluden-1 (ZO-1), E-cadherin, β-catenin, interleukin 1β (IL-1β), cyclooxygenase-2 (COX-2), transforming growth factor β-1 (TGFβ1), and fibronectin were measured. Tissue structural alterations were assessed using transmission electron microscopy (TEM). Transepithelial resistance was used to measure functional tissue outcomes. Results Occludin gene expression was downregulated in vocal folds exposed to 120 minute time doses of raised intensity phonation, relative to control, and modal intensity phonation. ZO-1 gene expression was upregulated following a 120 minute time dose of modal intensity phonation, compared to control, and downregulated after a 120 minute time dose of raised intensity phonation, compared to modal intensity phonation. E-cadherin gene expression was downregulated after a120 minute time dose of raised intensity phonation, compared to control and modal intensity phonation. TEM revealed extensive desquamation of the stratified squamous epithelial cells with increasing time and magnitude doses of vibration exposure. A general observation of lower transepithelial resistance measures was made in tissues exposed to raised intensity phonation, compared to all other groups. Conclusions This study provides evidence of vocal fold tissue responses to varying time and magnitude doses of vibration exposure. Level of Evidence N/A PMID:25073715

  5. Improved measurement linearity and precision for AMCW time-of-flight range imaging cameras.

    PubMed

    Payne, Andrew D; Dorrington, Adrian A; Cree, Michael J; Carnegie, Dale A

    2010-08-10

    Time-of-flight range imaging systems utilizing the amplitude modulated continuous wave (AMCW) technique often suffer from measurement nonlinearity due to the presence of aliased harmonics within the amplitude modulation signals. Typically a calibration is performed to correct these errors. We demonstrate an alternative phase encoding approach that attenuates the harmonics during the sampling process, thereby improving measurement linearity in the raw measurements. This mitigates the need to measure the system's response or calibrate for environmental changes. In conjunction with improved linearity, we demonstrate that measurement precision can also be increased by reducing the duty cycle of the amplitude modulated illumination source (while maintaining overall illumination power).

  6. Multiplexed Nanoplasmonic Temporal Profiling of T-Cell Response under Immunomodulatory Agent Exposure

    PubMed Central

    2016-01-01

    Immunomodulatory drugs—agents regulating the immune response—are commonly used for treating immune system disorders and minimizing graft versus host disease in persons receiving organ transplants. At the cellular level, immunosuppressant drugs are used to inhibit pro-inflammatory or tissue-damaging responses of cells. However, few studies have so far precisely characterized the cellular-level effect of immunomodulatory treatment. The primary challenge arises due to the rapid and transient nature of T-cell immune responses to such treatment. T-cell responses involve a highly interactive network of different types of cytokines, which makes precise monitoring of drug-modulated T-cell response difficult. Here, we present a nanoplasmonic biosensing approach to quantitatively characterize cytokine secretion behaviors of T cells with a fine time-resolution (every 10 min) that are altered by an immunosuppressive drug used in the treatment of T-cell-mediated diseases. With a microfluidic platform integrating antibody-conjugated gold nanorod (AuNR) arrays, the technique enables simultaneous multi-time-point measurements of pro-inflammatory (IL-2, IFN-γ, and TNF-α) and anti-inflammatory (IL-10) cytokines secreted by T cells. The integrated nanoplasmonic biosensors achieve precise measurements with low operating sample volume (1 μL), short assay time (∼30 min), heightened sensitivity (∼20–30 pg/mL), and negligible sensor crosstalk. Data obtained from the multicytokine secretion profiles with high practicality resulting from all of these sensing capabilities provide a comprehensive picture of the time-varying cellular functional state during pharmacologic immunosuppression. The capability to monitor cellular functional response demonstrated in this study has great potential to ultimately permit personalized immunomodulatory treatment. PMID:27478873

  7. Using perceptual cues for brake response to a lead vehicle: Comparing threshold and accumulator models of visual looming.

    PubMed

    Xue, Qingwan; Markkula, Gustav; Yan, Xuedong; Merat, Natasha

    2018-06-18

    Previous studies have shown the effect of a lead vehicle's speed, deceleration rate and headway distance on drivers' brake response times. However, how drivers perceive this information and use it to determine when to apply braking is still not quite clear. To better understand the underlying mechanisms, a driving simulator experiment was performed where each participant experienced nine deceleration scenarios. Previously reported effects of the lead vehicle's speed, deceleration rate and headway distance on brake response time were firstly verified in this paper, using a multilevel model. Then, as an alternative to measures of speed, deceleration rate and distance, two visual looming-based metrics (angular expansion rate θ˙ of the lead vehicle on the driver's retina, and inverse tau τ -1 , the ratio between θ˙ and the optical size θ), considered to be more in line with typical human psycho-perceptual responses, were adopted to quantify situation urgency. These metrics were used in two previously proposed mechanistic models predicting brake onset: either when looming surpasses a threshold, or when the accumulated evidence (looming and other cues) reaches a threshold. Results showed that the looming threshold model did not capture the distribution of brake response time. However, regardless of looming metric, the accumulator models fitted the distribution of brake response times better than the pure threshold models. Accumulator models, including brake lights, provided a better model fit than looming-only versions. For all versions of the mechanistic models, models using τ -1 as the measure of looming fitted better than those using θ˙, indicating that the visual cues drivers used during rear-end collision avoidance may be more close to τ -1 . Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. SU-E-I-88: The Effect of System Dead Time On Real-Time Plastic and GOS Based Fiber-Optic Dosimetry Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoerner, M; Hintenlang, D

    Purpose: A methodology is presented to correct for measurement inaccuracies at high detector count rates using a plastic and GOS scintillation fibers coupled to a photomultiplier tube with digital readout. This system allows temporal acquisition and manipulation of measured data. Methods: The detection system used was a plastic scintillator and a separate gadolinium scintillator, both (0.5 diameter) coupled to an optical fiber with a Hamamatsu photon counter with a built-in microcontroller and digital interface. Count rate performance of the system was evaluated using the nonparalzable detector model. Detector response was investigated across multiple radiation sources including: orthovoltage x-ray system, colbat-60more » gamma rays, proton therapy beam, and a diagnostic radiography x-ray tube. The dead time parameter was calculated by measuring the count rate of the system at different exposure rates using a reference detector. Results: The system dead time was evaluated for the following sources of radiation used clinically: diagnostic energy x-rays, cobalt-60 gamma rays, orthovoltage xrays, particle proton accelerator, and megavoltage x-rays. It was found that dead time increased significantly when exposing the detector to sources capable of generating Cerenkov radiation, all of the sources sans the diagnostic x-rays, with increasing prominence at higher photon energies. Percent depth dose curves generated by a dedicated ionization chamber and compared to the detection system demonstrated that correcting for dead time improves accuracy. On most sources, nonparalzable model fit provided an improved system response. Conclusion: Overall, the system dead time was variable across the investigated radiation particles and energies. It was demonstrated that the system response accuracy was greatly improved by correcting for dead time effects. Cerenkov radiation plays a significant role in the increase in the system dead time through transient absorption effects attributed to electron hole-pair creations within the optical waveguide.« less

  9. Interindividual Responses of Appetite to Acute Exercise: A Replicated Crossover Study.

    PubMed

    Goltz, Fernanda R; Thackray, Alice E; King, James A; Dorling, James L; Atkinson, Greg; Stensel, David J

    2018-04-01

    Acute exercise transiently suppresses appetite, which coincides with alterations in appetite-regulatory hormone concentrations. Individual variability in these responses is suspected, but replicated trials are needed to quantify them robustly. We examined the reproducibility of appetite and appetite-regulatory hormone responses to acute exercise and quantified the individual differences in responses. Fifteen healthy, recreationally active men completed two control (60-min resting) and two exercise (60-min fasted treadmill running at 70% peak oxygen uptake) conditions in randomized sequences. Perceived appetite and circulating concentrations of acylated ghrelin and total peptide YY (PYY) were measured immediately before and after the interventions. Interindividual differences were explored by correlating the two sets of response differences between exercise and control conditions. Within-participant covariate-adjusted linear mixed models were used to quantify participant-condition interactions. Compared with control, exercise suppressed mean acylated ghrelin concentrations and appetite perceptions (all ES = 0.62-1.47, P < 0.001) and elevated total PYY concentrations (ES = 1.49, P < 0.001). For all variables, the standard deviation of the change scores was substantially greater in the exercise versus control conditions. Moderate-to-large positive correlations were observed between the two sets of control-adjusted exercise responses for all variables (r = 0.54-0.82, P ≤ 0.036). After adjusting for baseline measurements, participant-condition interactions were present for all variables (P ≤ 0.053). Our replicated crossover study allowed, for the first time, the interaction between participant and acute exercise response in appetite parameters to be quantified. Even after adjustment for individual baseline measurements, participants demonstrated individual differences in perceived appetite and hormone responses to acute exercise bouts beyond any random within-subject variability over time.

  10. Identification of Scattering Mechanisms from Measured Impulse Response Signatures of Several Conducting Objects.

    DTIC Science & Technology

    1984-02-01

    conducting sphere 35 compared to inverse transform of exact solution. 4-5. Measured impulse response of a conducting 2:1 right 37 circular cylinder with...frequency domain. This is equivalent to multiplication in the time domain by the inverse transform of w(n), which is shown in Figure 3-1 for N=15. The...equivalent pulse width from 0.066 T for the rectangular window to 0.10 T for the Hanning window. The inverse transform of the Hanning window is shown

  11. A High Resolution Liquid Xenon Imaging Telescope for 0.3-10 MeV Gamma Ray Astrophysics: Construction and Initial Balloon Flights

    NASA Technical Reports Server (NTRS)

    Aprile, Elena

    1993-01-01

    The results achieved with a 3.5 liter liquid xenon time projection chamber (LXe-TPC) prototype during the first year include: the efficiency of detecting the primary scintillation light for event triggering has been measured to be higher than 85%; the charge response has been measured to be stable to within 0.1% for a period of time of about 30 hours; the electron lifetime has been measured to be in excess of 1.3 ms; the energy resolution has been measured to be consistent with previous results obtained with small volume chambers; X-Y gamma ray imaging has been demonstrated with a nondestructive orthogonal wires readout; Monte Carlo simulation results on detection efficiency, expected background count rate at balloon altitude, background reduction algorithms, telescope response to point-like and diffuse sources, and polarization sensitivity calculations; and work on a 10 liter LXe-TPC prototype and gas purification/recovery system.

  12. Effect of Occupational Therapy-Led Playgroups in Early Intervention on Child Playfulness and Caregiver Responsiveness: A Repeated-Measures Design.

    PubMed

    Fabrizi, Sarah E; Ito, Max A; Winston, Kristin

    2016-01-01

    This study's objective was to investigate the effects of a community playgroup on the playfulness of children with special needs ages 15 mo to 3 yr and the responsiveness of their caregivers. Using a pretest-posttest, repeated-measures design, we evaluated 8 child-caregiver dyads participating in an 8-wk occupational therapist-led community playgroup recruited from a purposive sample enrolled in early intervention. Video recordings from four time points over 4 mo were used to determine playfulness (Test of Playfulness) of the child and the responsiveness of the caregiver. Blinded raters assessed playfulness and responsiveness outcomes. A repeated-measures analysis of variance demonstrated that participation in the playgroup significantly increased child playfulness (ηp² = .89, p < .01). Analysis did not detect a change in caregiver responsiveness. The results of this study have implications for the use of playgroups in comprehensive occupational therapy practice in early intervention. Copyright © 2016 by the American Occupational Therapy Association, Inc.

  13. Postural effects on the noninvasive baselines of ventricular performance

    NASA Technical Reports Server (NTRS)

    Lance, V. Q.; Spodick, D. H.

    1977-01-01

    The effects of posture on time-based noninvasive measurements were determined utilizing the sequence supine-sitting-standing in a formal protocol in which observer biases were eliminated by blinding the measurement and calculation phases. Compared to the supine posture, the sitting and standing postures produced significant increases in heart rate, isovolumic contraction time, pre-ejection period and pre-ejection period/left-ventricular ejection time and significant decreases in ejection time and ejection time index. The response patterns are consistent with the hemodynamic correlates cited in the literature which show increased adrenergic activity and decreased venous return in the sitting and standing postures, the effect on venous return being dominant.

  14. Preserved search asymmetry in the detection of fearful faces among neutral faces in individuals with Williams syndrome revealed by measurement of both manual responses and eye tracking.

    PubMed

    Hirai, Masahiro; Muramatsu, Yukako; Mizuno, Seiji; Kurahashi, Naoko; Kurahashi, Hirokazu; Nakamura, Miho

    2017-01-01

    Individuals with Williams syndrome (WS) exhibit an atypical social phenotype termed hypersociability. One theory accounting for hypersociability presumes an atypical function of the amygdala, which processes fear-related information. However, evidence is lacking regarding the detection mechanisms of fearful faces for individuals with WS. Here, we introduce a visual search paradigm to elucidate the mechanisms for detecting fearful faces by evaluating the search asymmetry; the reaction time when both the target and distractors were swapped was asymmetrical. Eye movements reflect subtle atypical attentional properties, whereas, manual responses are unable to capture atypical attentional profiles toward faces in individuals with WS. Therefore, we measured both eye movements and manual responses of individuals with WS and typically developed children and adults in visual searching for a fearful face among neutral faces or a neutral face among fearful faces. Two task measures, namely reaction time and performance accuracy, were analyzed for each stimulus as well as gaze behavior and the initial fixation onset latency. Overall, reaction times in the WS group and the mentally age-matched control group were significantly longer than those in the chronologically age-matched group. We observed a search asymmetry effect in all groups: when a neutral target facial expression was presented among fearful faces, the reaction times were significantly prolonged in comparison with when a fearful target facial expression was displayed among neutral distractor faces. Furthermore, the first fixation onset latency of eye movement toward a target facial expression showed a similar tendency for manual responses. Although overall responses in detecting fearful faces for individuals with WS are slower than those for control groups, search asymmetry was observed. Therefore, cognitive mechanisms underlying the detection of fearful faces seem to be typical in individuals with WS. This finding is discussed with reference to the amygdala account explaining hypersociability in individuals with WS.

  15. Psychological traits influence autonomic nervous system recovery following esophageal intubation in health and functional chest pain.

    PubMed

    Farmer, A D; Coen, S J; Kano, M; Worthen, S F; Rossiter, H E; Navqi, H; Scott, S M; Furlong, P L; Aziz, Q

    2013-12-01

    Esophageal intubation is a widely utilized technique for a diverse array of physiological studies, activating a complex physiological response mediated, in part, by the autonomic nervous system (ANS). In order to determine the optimal time period after intubation when physiological observations should be recorded, it is important to know the duration of, and factors that influence, this ANS response, in both health and disease. Fifty healthy subjects (27 males, median age 31.9 years, range 20-53 years) and 20 patients with Rome III defined functional chest pain (nine male, median age of 38.7 years, range 28-59 years) had personality traits and anxiety measured. Subjects had heart rate (HR), blood pressure (BP), sympathetic (cardiac sympathetic index, CSI), and parasympathetic nervous system (cardiac vagal tone, CVT) parameters measured at baseline and in response to per nasum intubation with an esophageal catheter. CSI/CVT recovery was measured following esophageal intubation. In all subjects, esophageal intubation caused an elevation in HR, BP, CSI, and skin conductance response (SCR; all p < 0.0001) but concomitant CVT and cardiac sensitivity to the baroreflex (CSB) withdrawal (all p < 0.04). Multiple linear regression analysis demonstrated that longer CVT recovery times were independently associated with higher neuroticism (p < 0.001). Patients had prolonged CSI and CVT recovery times in comparison to healthy subjects (112.5 s vs 46.5 s, p = 0.0001 and 549 s vs 223.5 s, p = 0.0001, respectively). Esophageal intubation activates a flight/flight ANS response. Future studies should allow for at least 10 min of recovery time. Consideration should be given to psychological traits and disease status as these can influence recovery. © 2013 John Wiley & Sons Ltd.

  16. Selective resolution of photocurrent generating pathways in transition metal dichalcogenides by ultrafast microscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Graham, Matthew W.

    2017-02-01

    Presently, there exists no reliable in-situ time-resolved method that selectively isolates both the recombination and escape times relevant to photocurrent generation in the ultrafast regime. Transport based measurements lack the required time resolution, while purely optical measurement give a convoluted weighted-average of all electronic dynamics, offering no selectivity for photocurrent generating pathways. Recently, the ultrafast photocurrent (U-PC) autocorrelation method has successfully measured the rate limiting electronic relaxation processes in materials such as graphene, carbon nanotubes, and transition metal dichalcogenide (TMD) materials. Here, we unambiguously derive and experimentally confirm a generic U-PC response function by simultaneously resolving the transient absorption (TA) and U-PC response for highly-efficient (48% IQE at 0 bias) WSe2 devices and twisted bilayer graphene. Surprisingly, both optical TA and electrical U-PC responses give the same E-field-dependent electronic escape and recombination rates. These rates further accurately quantify a material's intrinsic PC generation efficiency. We demonstrate that the chirality of the incident light impacts the U-PC kinetics, suggesting such measurements directly access the ultrafast dynamics need to complex electronic physics such as the valley-Hall effect. By combining E-field dependent ultrafast photocurrent with transient absorption microscopy, we have selectively imaged the dominant kinetic bottlenecks that inhibit photocurrent production in devices made from stacked few-layer TMD materials. This provides a new methodology to intelligently select materials that intrinsically avoid recombination bottlenecks and maximize photocurrent yield.

  17. The Influence of Noise Reduction on Speech Intelligibility, Response Times to Speech, and Perceived Listening Effort in Normal-Hearing Listeners.

    PubMed

    van den Tillaart-Haverkate, Maj; de Ronde-Brons, Inge; Dreschler, Wouter A; Houben, Rolph

    2017-01-01

    Single-microphone noise reduction leads to subjective benefit, but not to objective improvements in speech intelligibility. We investigated whether response times (RTs) provide an objective measure of the benefit of noise reduction and whether the effect of noise reduction is reflected in rated listening effort. Twelve normal-hearing participants listened to digit triplets that were either unprocessed or processed with one of two noise-reduction algorithms: an ideal binary mask (IBM) and a more realistic minimum mean square error estimator (MMSE). For each of these three processing conditions, we measured (a) speech intelligibility, (b) RTs on two different tasks (identification of the last digit and arithmetic summation of the first and last digit), and (c) subjective listening effort ratings. All measurements were performed at four signal-to-noise ratios (SNRs): -5, 0, +5, and +∞ dB. Speech intelligibility was high (>97% correct) for all conditions. A significant decrease in response time, relative to the unprocessed condition, was found for both IBM and MMSE for the arithmetic but not the identification task. Listening effort ratings were significantly lower for IBM than for MMSE and unprocessed speech in noise. We conclude that RT for an arithmetic task can provide an objective measure of the benefit of noise reduction. For young normal-hearing listeners, both ideal and realistic noise reduction can reduce RTs at SNRs where speech intelligibility is close to 100%. Ideal noise reduction can also reduce perceived listening effort.

  18. Direct Observation of Electron Capture and Reemission by the Divacancy via Charge Transient Positron Spectroscopy

    NASA Astrophysics Data System (ADS)

    Edwardson, C. J.; Coleman, P. G.; Paez, D. J.; Doylend, J. K.; Knights, A. P.

    2013-03-01

    Electron capture during forward bias and reemission at zero bias by divacancies in the depletion region of a silicon diode structure at room temperature have been studied for the first time using monoenergetic positrons. The positron response increases essentially linearly with electron current, as a result of increased positron trapping by negatively charged divacancies. The measurements indicate that ≤1% of the divacancies become negatively charged in the steady state at a forward bias of 1 V. Changes in the mean positron response when applying a square wave bias to the sample (1 V forward bias and 0 V, duty cycle 1∶4, times at 0 V in the range 0.1-100μs), were consistent with a rapid conversion of doubly to singly charged divacancies (in ˜101ns), followed by slower defilling of the singly charged divacancies with a time constant of ˜101μs. These ac measurements allow determination of the relative populations of singly and doubly charged divacancies. The results provide confirmation of consistency between the positron’s response to the silicon divacancy and previously extracted capture and emission kinetics determined through charge transient measurements and assigned to the same defect. The possibility of combining these two, orthogonal techniques suggest a promising new and powerful approach to defect spectroscopy in which the structure and electrical properties of a defect may be determined in a single measurement.

  19. Design, fabrication, and measurement of two silicon-based ultraviolet and blue-extended photodiodes

    NASA Astrophysics Data System (ADS)

    Chen, Changping; Wang, Han; Jiang, Zhenyu; Jin, Xiangliang; Luo, Jun

    2014-12-01

    Two silicon-based ultraviolet (UV) and blue-extended photodiodes are presented, which were fabricated for light detection in the ultraviolet/blue spectral range. Stripe-shaped and octagon-ring-shaped structures were designed to verify parameters of the UV-responsivity, UV-selectivity, breakdown voltage, and response time. The ultra-shallow lateral pn junction had been successfully realized in a standard 0.5-μm complementary metal oxide semiconductor (CMOS) process to enlarge the pn junction area, enhance the absorption of UV light, and improve the responsivity and quantum efficiency. The test results illustrated that the stripe-shaped structure has the lower breakdown voltage, higher UV-responsicity, and higher UV-selectivity. But the octagon-ring-shaped structure has the lower dark current. The response time of both structures was almost the same.

  20. Sources of uncertanity as a basis to fill the information gap in a response to flood

    NASA Astrophysics Data System (ADS)

    Kekez, Toni; Knezic, Snjezana

    2016-04-01

    Taking into account uncertainties in flood risk management remains a challenge due to difficulties in choosing adequate structural and/or non-structural risk management options. Despite stated measures wrong decisions are often being made when flood occurs. Parameter and structural uncertainties which include model and observation errors as well as lack of knowledge about system characteristics are the main considerations. Real time flood risk assessment methods are predominantly based on measured water level values and vulnerability as well as other relevant characteristics of flood affected area. The goal of this research is to identify sources of uncertainties and to minimize information gap between the point where the water level is measured and the affected area, taking into consideration main uncertainties that can affect risk value at the observed point or section of the river. Sources of uncertainties are identified and determined using system analysis approach and relevant uncertainties are included in the risk assessment model. With such methodological approach it is possible to increase response time with more effective risk assessment which includes uncertainty propagation model. Response phase could be better planned with adequate early warning systems resulting in more time and less costs to help affected areas and save human lives. Reliable and precise information is necessary to raise emergency operability level in order to enhance safety of citizens and reducing possible damage. The results of the EPISECC (EU funded FP7) project are used to validate potential benefits of this research in order to improve flood risk management and response methods. EPISECC aims at developing a concept of a common European Information Space for disaster response which, among other disasters, considers the floods.

Top