Response Time Analysis and Test of Protection System Instrument Channels for APR1400 and OPR1000
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Chang Jae; Han, Seung; Yun, Jae Hee
2015-07-01
Safety limits are required to maintain the integrity of physical barriers designed to prevent the uncontrolled release of radioactive materials in nuclear power plants. The safety analysis establishes two critical constraints that include an analytical limit in terms of a measured or calculated variable, and a specific time after the analytical limit is reached to begin protective action. Keeping with the nuclear regulations and industry standards, satisfying these two requirements will ensure that the safety limit will not be exceeded during the design basis event, either an anticipated operational occurrence or a postulated accident. Various studies on the setpoint determinationmore » methodology for the safety-related instrumentation have been actively performed to ensure that the requirement of the analytical limit is satisfied. In particular, the protection setpoint methodology for the advanced power reactor 1400 (APP1400) and the optimized power reactor 1000 (OPR1000) has been recently developed to cover both the design basis event and the beyond design basis event. The developed setpoint methodology has also been quantitatively validated using specific computer programs and setpoint calculations. However, the safety of nuclear power plants cannot be fully guaranteed by satisfying the requirement of the analytical limit. In spite of the response time verification requirements of nuclear regulations and industry standards, it is hard to find the studies on the systematically integrated methodology regarding the response time evaluation. In cases of APR1400 and OPR1000, the response time analysis for the plant protection system is partially included in the setpoint calculation and the response time test is separately performed via the specific plant procedure. The test technique has a drawback which is the difficulty to demonstrate completeness of timing test. The analysis technique has also a demerit of resulting in extreme times that not actually possible. Thus, the establishment of the systematic response time evaluation methodology is needed to justify the conformance to the response time requirement used in the safety analysis. This paper proposes the response time evaluation methodology for APR1400 and OPR1000 using the combined analysis and test technique to confirm that the plant protection system can meet the analytical response time assumed in the safety analysis. In addition, the results of the quantitative evaluation performed for APR1400 and OPR1000 are presented in this paper. The proposed response time analysis technique consists of defining the response time requirement, determining the critical signal path for the trip parameter, allocating individual response time to each component on the signal path, and analyzing the total response time for the trip parameter, and demonstrates that the total analyzed response time does not exceed the response time requirement. The proposed response time test technique is composed of defining the response time requirement, determining the critical signal path for the trip parameter, determining the test method for each component on the signal path, performing the response time test, and demonstrates that the total test result does not exceed the response time requirement. The total response time should be tested in a single test that covers from the sensor to the final actuation device on the instrument channel. When the total channel is not tested in a single test, separate tests on groups of components or single components including the total instrument channel shall be combined to verify the total channel response. For APR1400 and OPR1000, the ramp test technique is used for the pressure and differential pressure transmitters and the step function testing technique is applied to the signal processing equipment and final actuation device. As a result, it can be demonstrated that the response time requirement is satisfied by the combined analysis and test technique. Therefore, the proposed methodology in this paper plays a crucial role in guaranteeing the safety of the nuclear power plants systematically satisfying one of two critical requirements from the safety analysis. (authors)« less
A Flexible Latent Trait Model for Response Times in Tests
ERIC Educational Resources Information Center
Ranger, Jochen; Kuhn, Jorg-Tobias
2012-01-01
Latent trait models for response times in tests have become popular recently. One challenge for response time modeling is the fact that the distribution of response times can differ considerably even in similar tests. In order to reduce the need for tailor-made models, a model is proposed that unifies two popular approaches to response time…
Testing for Aberrant Behavior in Response Time Modeling
ERIC Educational Resources Information Center
Marianti, Sukaesi; Fox, Jean-Paul; Avetisyan, Marianna; Veldkamp, Bernard P.; Tijmstra, Jesper
2014-01-01
Many standardized tests are now administered via computer rather than paper-and-pencil format. In a computer-based testing environment, it is possible to record not only the test taker's response to each question (item) but also the amount of time spent by the test taker in considering and answering each item. Response times (RTs) provide…
Rise time and response measurements on a LiSOCl2 cell
NASA Technical Reports Server (NTRS)
Bastien, Caroline; Lecomte, Eric J.
1992-01-01
Dynamic impedance tests were performed on a 180 Ah LiSOCl2 cell in the frame of a short term work contract awarded by Aerospatiale as part of the Hermes Space Plane development work. These tests consisted of rise time and response measurements. The rise time test was performed to show the ability to deliver 4 KW, in the nominal voltage range (75-115 V), within less than 100 microseconds, and after a period at rest of 13 days. The response measurements test consisted of step response and frequency response tests. The frequency response test was performed to characterize the response of the LiSOCl2 cell to a positive or negative load step of 10 A starting from various currents. The test was performed for various depths of discharge and various temperatures. The test results were used to build a mathematical, electrical model of the LiSOCl2 cell which are also presented. The test description, test results, electrical modelization description, and conclusions are presented.
Lourenço, Felipe Rebello; Botelho, Túlia De Souza; Pinto, Terezinha De Jesus Andreoli
2012-01-01
The limulus amebocyte lysate (LAL) test is the simplest and most widely used procedure for detection of endotoxin in parenteral drugs. The LAL test demands optimal pH, ionic strength, temperature, and time of incubation. Slight changes in these parameters may increase the frequency of false-positive responses and the estimated uncertainty of the LAL test. The aim of this paper is to evaluate how changes in the pH, temperature, and time of incubation affect the occurrence of false-positive responses in the LAL test. LAL tests were performed in nominal conditions (37 °C, 60 min, and pH 7) and in different conditions of temperature (36 °C and 38 °C), time of incubation (58 and 62 min), and pH (6 and 8). Slight differences in pH increase the frequency of false-positive responses 5-fold (relative risk 5.0), resulting in an estimated of uncertainty 7.6%. Temperature and time of incubation affect the LAL test less, showing relative risks of 1.5 and 1.0, respectively. Estimated uncertainties in 36 °C or 38 °C temperatures and 58 or 62 min of incubation were found to be 2.0% and 1.0%, respectively. Simultaneous differences in these parameters significantly increase the frequency of false-positive responses. The limulus amebocyte lysate (LAL) gel-clot test is a simple test for detection of endotoxin from Gram-negative bacteria. The test is based on a gel formation when a certain amount of endotoxin is present; it is a pass/fail test. The LAL test requires optimal pH, ionic strength, temperature, and time of incubation. Slight difference in these parameters may increase the frequency of false-positive responses. The aim of this paper is to evaluate how changes in the pH, temperature, and time of incubation affect the occurrence of false-positive responses in the LAL test. We find that slight differences in pH increase the frequency of false-positive responses 5-fold. Temperature and time of incubation affect the LAL test less. Simultaneous differences in these parameters significantly increase the frequency of false-positive responses.
A Multivariate Multilevel Approach to the Modeling of Accuracy and Speed of Test Takers
ERIC Educational Resources Information Center
Klein Entink, R. H.; Fox, J. P.; van der Linden, W. J.
2009-01-01
Response times on test items are easily collected in modern computerized testing. When collecting both (binary) responses and (continuous) response times on test items, it is possible to measure the accuracy and speed of test takers. To study the relationships between these two constructs, the model is extended with a multivariate multilevel…
An Analysis of Variance Approach for the Estimation of Response Time Distributions in Tests
ERIC Educational Resources Information Center
Attali, Yigal
2010-01-01
Generalizability theory and analysis of variance methods are employed, together with the concept of objective time pressure, to estimate response time distributions and the degree of time pressure in timed tests. By estimating response time variance components due to person, item, and their interaction, and fixed effects due to item types and…
A window on perception: Response times of odontocete cetaceans in audiometric tests
NASA Astrophysics Data System (ADS)
Blackwood, Diane J.; Ridgway, Sam H.; Evans, William E.
2002-05-01
A standard psychometric measurement is response time, the interval elapsing between a stimulus and a response. While studies of response time have been published for humans and other terrestrial mammals, this study marks the first report of response times for odontocete cetaceans at threshold in an audiometric task. Two white whales (Delphinapterus leucas) and four Atlantic bottlenose dolphins (Tursiops truncatus) were given audiometric tests to determine masked hearing thresholds. Animals were tested at 26 frequencies over a range from 200 Hz to 100 kHz using pure tones. The test tone amplitudes covered a range of 20 dB re 1 microPascal including the hearing threshold of the animal at that frequency. Hearing thresholds varied from 87.5 dB to 125.5 dB depending on frequency, masking noise intensity and individual animal. Data was analyzed to determine characteristic relationships between response time and amplitude of test tone for each frequency and animal. The two whales responded significantly slower (640 ms, 0.001) than the four dolphins (430 ms). As in terrestrial animals, reaction time became shorter as stimulus strength increased. At threshold, median response time across frequencies within each animal varied about 150 ms.
An Analysis of Task-Scheduling for a Generic Avionics Mission Computer
2006-04-01
3 3. 1. 3 Response Time Analysis........................................................................... 8 3. 2 Non - Preemptive ...Fixed Priority Scheduling ...................................................... 10 3. 2. 1 Simple Non - Preemptive Response Time Test...10 3. 2. 2 Non - Preemptive Response Time Test .................................................. 12 3. 3 Asynchronous Fixed
Using Response Times for Item Selection in Adaptive Testing
ERIC Educational Resources Information Center
van der Linden, Wim J.
2008-01-01
Response times on items can be used to improve item selection in adaptive testing provided that a probabilistic model for their distribution is available. In this research, the author used a hierarchical modeling framework with separate first-level models for the responses and response times and a second-level model for the distribution of the…
Factors Influencing Ball-Player Impact Probability in Youth Baseball
Matta, Philip A.; Myers, Joseph B.; Sawicki, Gregory S.
2015-01-01
Background: Altering the weight of baseballs for youth play has been studied out of concern for player safety. Research has shown that decreasing the weight of baseballs may limit the severity of both chronic arm and collision injuries. Unfortunately, reducing the weight of the ball also increases its exit velocity, leaving pitchers and nonpitchers with less time to defend themselves. The purpose of this study was to examine impact probability for pitchers and nonpitchers. Hypothesis: Reducing the available time to respond by 10% (expected from reducing ball weight from 142 g to 113 g) would increase impact probability for pitchers and nonpitchers, and players’ mean simple response time would be a primary predictor of impact probability for all participants. Study Design: Nineteen subjects between the ages of 9 and 13 years performed 3 experiments in a controlled laboratory setting: a simple response time test, an avoidance response time test, and a pitching response time test. Methods: Each subject performed these tests in order. The simple reaction time test tested the subjects’ mean simple response time, the avoidance reaction time test tested the subjects’ ability to avoid a simulated batted ball as a fielder, and the pitching reaction time test tested the subjects’ ability to avoid a simulated batted ball as a pitcher. Results: Reducing the weight of a standard baseball from 142 g to 113 g led to a less than 5% increase in impact probability for nonpitchers. However, the results indicate that the impact probability for pitchers could increase by more than 25%. Conclusion: Pitching may greatly increase the amount of time needed to react and defend oneself from a batted ball. Clinical Relevance: Impact injuries to youth baseball players may increase if a 113-g ball is used. PMID:25984261
King, P M
1997-01-01
The purpose of this study was to determine if a correlation exists between touch-pressure threshold testing and sensory discrimination function, specifically tactile gnosis for texture and object recognition. Twenty-nine patients diagnosed with carpal tunnel syndrome (CTS), as confirmed by electromyography or nerve conduction velocity tests, were administered three sensibility tests: the Semmes-Weinstein monofilament test, a texture discrimination test, and an object identification test. Norms were established for texture and object recognition tests using 100 subjects (50 females and 50 males) with normal touch-pressure thresholds as assessed by the Semmes-Weinstein monofilament test. The CTS patients were grouped into three categories of sensibility as determined by their performance on the Semmes-Weinstein monofilament test: normal, diminished light touch, and diminished protective sensation. Through an independent t test statistical procedure, each of the three categories mean response times for identification of textures of objects were compared with the normed response times. Accurate responses were given for identification of all textures and objects. No significant difference (p < .05) was noted in mean response times of the CTS patients with normal touch-pressure thresholds. A significant difference (p < .05) in response times by those CTS patients with diminished light touch was detected in identification in four out of six objects. Subjects with diminished protective sensation had significantly longer response times (p < .05) for identification of the textures of cork, coarse and fine sandpaper, and rubber. Significantly longer response times were recorded by the same subjects for identification of such objects as a screw and a button, and for the shapes of a square, triangle, and oval.
ESTIMATION OF ACUTE TOXICITY BY FITTING A DOSE-TIME RESPONSE SURFACE
In acute toxicity testing, organisms are continuously exposed to progressively increasing concentrations of a chemical and deaths of test organisms are recorded at several selected times. he results of the test are traditionally summarized by a dose-response curve, and the time c...
Response Time as an Indicator of Test Taker Speed: Assumptions Meet Reality
ERIC Educational Resources Information Center
Wise, Steven L.
2015-01-01
The growing presence of computer-based testing has brought with it the capability to routinely capture the time that test takers spend on individual test items. This, in turn, has led to an increased interest in potential applications of response time in measuring intellectual ability and achievement. Goldhammer (this issue) provides a very useful…
Input-output characterization of an ultrasonic testing system by digital signal analysis
NASA Technical Reports Server (NTRS)
Williams, J. H., Jr.; Lee, S. S.; Karagulle, H.
1986-01-01
Ultrasonic test system input-output characteristics were investigated by directly coupling the transmitting and receiving transducers face to face without a test specimen. Some of the fundamentals of digital signal processing were summarized. Input and output signals were digitized by using a digital oscilloscope, and the digitized data were processed in a microcomputer by using digital signal-processing techniques. The continuous-time test system was modeled as a discrete-time, linear, shift-invariant system. In estimating the unit-sample response and frequency response of the discrete-time system, it was necessary to use digital filtering to remove low-amplitude noise, which interfered with deconvolution calculations. A digital bandpass filter constructed with the assistance of a Blackman window and a rectangular time window were used. Approximations of the impulse response and the frequency response of the continuous-time test system were obtained by linearly interpolating the defining points of the unit-sample response and the frequency response of the discrete-time system. The test system behaved as a linear-phase bandpass filter in the frequency range 0.6 to 2.3 MHz. These frequencies were selected in accordance with the criterion that they were 6 dB below the maximum peak of the amplitude of the frequency response. The output of the system to various inputs was predicted and the results were compared with the corresponding measurements on the system.
A New Procedure for Detection of Students' Rapid Guessing Responses Using Response Time
ERIC Educational Resources Information Center
Guo, Hongwen; Rios, Joseph A.; Haberman, Shelby; Liu, Ou Lydia; Wang, Jing; Paek, Insu
2016-01-01
Unmotivated test takers using rapid guessing in item responses can affect validity studies and teacher and institution performance evaluation negatively, making it critical to identify these test takers. The authors propose a new nonparametric method for finding response-time thresholds for flagging item responses that result from rapid-guessing…
Jerosch-Herold, Christina
2003-06-01
A longitudinal dynamic cohort study was conducted on patients with median nerve injuries to evaluate the relative responsiveness of five sensibility tests: touch threshold using the WEST (monofilaments), static two-point discrimination, locognosia, a pick-up test and an object recognition test. Repeated assessments were performed starting at 6 months after surgery. In order to compare the relative responsiveness of each test, effect size and the standard response mean were calculated for sensibility changes occurring between 6 and 18 months after repair. Large effect sizes (>0.8) and standard response means (>0.8) were obtained for the WEST, locognosia, pick-up and object recognition tests. Two-point discrimination was hardly measurable at any time point and exhibited strong flooring effects. Further analysis of all time points was undertaken to assess the strength of the monotonic relationship between test scores and time elapsed since surgery. Comparison of monotonicity between the five tests indicated that the WEST performed best, whereas two-point discrimination performed worst. These results suggest that the monofilament test (WEST), locognosia test, Moberg pick-up test and tactile gnosis test capture sensibility changes over time well and should be considered for inclusion in the outcome assessment of patients with median nerve injury.
A Semiparametric Model for Jointly Analyzing Response Times and Accuracy in Computerized Testing
ERIC Educational Resources Information Center
Wang, Chun; Fan, Zhewen; Chang, Hua-Hua; Douglas, Jeffrey A.
2013-01-01
The item response times (RTs) collected from computerized testing represent an underutilized type of information about items and examinees. In addition to knowing the examinees' responses to each item, we can investigate the amount of time examinees spend on each item. Current models for RTs mainly focus on parametric models, which have the…
A Comparison of Pictorial and Speech Warning Messages in the Modern Cockpit.
1984-12-01
Significance Tests for Video Game Score in Experiment One .................................... 81 5. Significance Tests for Response Time in...91 7. Significance Tests for Video Game Score in Experiment Two ..................................... 96 8. Significance Tests for Response Time in...107 10. Significance Tests for Video Game Score in Experiment Three ................................. 112 Appendix Table 1C. Chi-Square Tests for
Effect of prolonged bedrest and plus Gz acceleration on peripheral visual response time
NASA Technical Reports Server (NTRS)
Haines, R. F.
1973-01-01
Peripheral visual response time changes during +G sub z acceleration following fourteen days of bedrest are considered as well as what effect prolonged bedrest has upon this response. Eighteen test lights, placed 10 deg are apart along the horizontal meridian of the subject's field of view, were presented in a random sequence. The subject was instructed to press a button as soon as a light appeared. Response time testing occurred periodically during bedrest and continuously during centrifugation testing. The results indicate that: (1) mean response time is significantly longer to stimuli imaged in the far periphery than to stimuli imaged closer to the line of sight; (2) mean response time at each stimulus position tends to be longer at plateau g than during the preacceleration baseline period; (3) mean response time tends to lengthen as the g level is increased; (4) peripheral visual response time during +G sub x acceleration at 2, 3.2, and 3.8 g was not a reliable advanced indicator that blackout was going to occur; and (5) the subject's field of view collapsed rapidly just before blackout. Bedrest data showed that the distribution of response times to stimuli imaged across the subject's horizontal retinal meridian remained remarkably constant from day to day during both the bedrest and recovery periods.
In-situ response time testing of thermocouples
NASA Astrophysics Data System (ADS)
Hashemian, H. M.; Petersen, K. M.; Hashemian, M.; Beverly, D. D.; Miller, L. F.
The Loop Current Step Response (LCSR) method has been developed for in situ response time testing of thermocouples and resistance thermometers. A means for measuring the sensor response for actual operating conditions and installation details is provided. This technology is ready to be assembled into an instrument for use in aerospace, nuclear, chemical and other industries where transient temperature measurements are important. The method provides time constant results within better than about 20 percent of value obtained from plunge tests. These results are based on tests performed in water at low flow rates (1M/sec) and in air flow rates ranging from a few meters per second to over a hundred kilometers per hour.
Definition of simulated driving tests for the evaluation of drivers' reactions and responses.
Bartolozzi, Riccardo; Frendo, Francesco
2014-01-01
This article aims at identifying the most significant measures in 2 perception-response (PR) tests performed at a driving simulator: a braking test and a lateral skid test, which were developed in this work. Forty-eight subjects (26 females and 22 males) with a mean age of 24.9 ± 3.0 years were enrolled for this study. They were asked to perform a drive on the driving simulator at the University of Pisa (Italy) following a specific test protocol, including 8-10 braking tests and 8-10 lateral skid tests. Driver input signals and vehicle model signals were recorded during the drives and analyzed to extract measures such as the reaction time, first response time, etc. Following a statistical procedure (based on analysis of variance [ANOVA] and post hoc tests), all test measures (3 for the braking test and 8 for the lateral skid test) were analyzed in terms of statistically significant differences among different drivers. The presented procedure allows evaluation of the capability of a given test to distinguish among different drivers. In the braking test, the reaction time showed a high dispersion among single drivers, leading to just 4.8 percent of statistically significant driver pairs (using the Games-Howell post hoc test), whereas the pedal transition time scored 31.9 percent. In the lateral skid test, 28.5 percent of the 2 × 2 comparisons showed significantly different reaction times, 19.5 percent had different response times, 35.2 percent had a different second peak of the steering wheel signal, and 33 percent showed different values of the integral of the steering wheel signal. For the braking test, which has been widely employed in similar forms in the literature, it was shown how the reaction time, with respect to the pedal transition time, can have a higher dispersion due to the influence of external factors. For the lateral skid test, the following measures were identified as the most significant for application studies: the reaction time for the reaction phase, the second peak of the steering wheel angle for the first instinctive response, and the integral of the steering wheel angle for the complete response. The methodology used to analyze the test measures was founded on statistically based and objective evaluation criteria and could be applied to other tests. Even if obtained with a fixed-base simulator, the obtained results represent useful information for applications of the presented PR tests in experimental campaigns with driving simulators.
Predictive Control of Speededness in Adaptive Testing
ERIC Educational Resources Information Center
van der Linden, Wim J.
2009-01-01
An adaptive testing method is presented that controls the speededness of a test using predictions of the test takers' response times on the candidate items in the pool. Two different types of predictions are investigated: posterior predictions given the actual response times on the items already administered and posterior predictions that use the…
2012-05-01
Settling Time Test .............................................................................................. 3-16 3.13 Overload Recovery Test...6-7 6.7 Inter-message Gap Time Test...6-8 6.8 Response Time Test ............................................................................................. 6-9 6.9
A General Approach to Measuring Test-Taking Effort on Computer-Based Tests
ERIC Educational Resources Information Center
Wise, Steven L.; Gao, Lingyun
2017-01-01
There has been an increased interest in the impact of unmotivated test taking on test performance and score validity. This has led to the development of new ways of measuring test-taking effort based on item response time. In particular, Response Time Effort (RTE) has been shown to provide an assessment of effort down to the level of individual…
A Box-Cox normal model for response times.
Klein Entink, R H; van der Linden, W J; Fox, J-P
2009-11-01
The log-transform has been a convenient choice in response time modelling on test items. However, motivated by a dataset of the Medical College Admission Test where the lognormal model violated the normality assumption, the possibilities of the broader class of Box-Cox transformations for response time modelling are investigated. After an introduction and an outline of a broader framework for analysing responses and response times simultaneously, the performance of a Box-Cox normal model for describing response times is investigated using simulation studies and a real data example. A transformation-invariant implementation of the deviance information criterium (DIC) is developed that allows for comparing model fit between models with different transformation parameters. Showing an enhanced description of the shape of the response time distributions, its application in an educational measurement context is discussed at length.
Sant'Ana, Jader; Franchini, Emerson; da Silva, Vinicius; Diefenthaeler, Fernando
2017-06-01
Reaction time and response time are considered important abilities and can potentially affect combat performance. This study investigated the effect of a specific fatigue protocol on reaction time, response time, performance time, and kick impact. Seven male athletes reported to the laboratory on two different days. During day one, athletes performed a specific progressive taekwondo test, and on day two, a protocol for determining reaction time, response time, performance time, and kick impact before and after a time to exhaustion test at an intensity level corresponding to the maximal kick frequency obtained during the specific progressive taekwondo test. Muscle activation from rectus femoris and kick impact of the preferred limb were assessed. No differences were observed for response time and performance time. However, kick impact decreased (43 ± 27 to 13 ± 10 g, p < 0.01) while reaction time increased (145 ± 51 to 223 ± 133 ms, p < 0.05). Moderate correlation was observed between kick impact and response time (r = 0.565; p < 0.01), and kick impact and performance time (r = 0.494; p < 0.05). Results indicate that coaches and athletes may use taekwondo training programmes on coordination-based exercises leading to improve response time and to reduce fatigue effects in order to improve technique effectiveness and enhance the possibilities of scoring in a competitive situation.
Three Essays on Teacher Education Programs and Test-Takers' Response Times on Test Items
ERIC Educational Resources Information Center
Qian, Hong
2013-01-01
This dissertation includes three essays: one essay focuses on the effect of teacher preparation programs on teacher knowledge while the other two focus on test-takers' response times on test items. Essay One addresses the problem of how opportunities to learn in teacher preparation programs influence future elementary mathematics teachers'…
ERIC Educational Resources Information Center
van der Linden, Wim J.; Scrams, David J.; Schnipke, Deborah L.
This paper proposes an item selection algorithm that can be used to neutralize the effect of time limits in computer adaptive testing. The method is based on a statistical model for the response-time distributions of the test takers on the items in the pool that is updated each time a new item has been administered. Predictions from the model are…
Van Schie, Mojca K M; Thijs, Roland D; Fronczek, Rolf; Middelkoop, Huub A M; Lammers, Gert Jan; Van Dijk, J Gert
2012-08-01
The sustained attention to response task comprises withholding key presses to one in nine of 225 target stimuli; it proved to be a sensitive measure of vigilance in a small group of narcoleptics. We studied sustained attention to response task results in 96 patients from a tertiary narcolepsy referral centre. Diagnoses according to ICSD-2 criteria were narcolepsy with (n=42) and without cataplexy (n=5), idiopathic hypersomnia without long sleep time (n=37), and obstructive sleep apnoea syndrome (n=12). The sustained attention to response task was administered prior to each of five multiple sleep latency test sessions. Analysis concerned error rates, mean reaction time, reaction time variability and post-error slowing, as well as the correlation of sustained attention to response task results with mean latency of the multiple sleep latency test and possible time of day influences. Median sustained attention to response task error scores ranged from 8.4 to 11.1, and mean reaction times from 332 to 366ms. Sustained attention to response task error score and mean reaction time did not differ significantly between patient groups. Sustained attention to response task error score did not correlate with multiple sleep latency test sleep latency. Reaction time was more variable as the error score was higher. Sustained attention to response task error score was highest for the first session. We conclude that a high sustained attention to response task error rate reflects vigilance impairment in excessive daytime sleepiness irrespective of its cause. The sustained attention to response task and the multiple sleep latency test reflect different aspects of sleep/wakefulness and are complementary. © 2011 European Sleep Research Society.
Code of Federal Regulations, 2011 CFR
2011-07-01
... meets a minimum response time. You may use the results of this test to determine transformation time, t... you use any analog or real-time digital filters during emission testing, you must operate those... the rise time and fall time as needed. You may also configure analog or digital filters before...
Reaction times to weak test lights. [psychophysics biological model
NASA Technical Reports Server (NTRS)
Wandell, B. A.; Ahumada, P.; Welsh, D.
1984-01-01
Maloney and Wandell (1984) describe a model of the response of a single visual channel to weak test lights. The initial channel response is a linearly filtered version of the stimulus. The filter output is randomly sampled over time. Each time a sample occurs there is some probability increasing with the magnitude of the sampled response - that a discrete detection event is generated. Maloney and Wandell derive the statistics of the detection events. In this paper a test is conducted of the hypothesis that the reaction time responses to the presence of a weak test light are initiated at the first detection event. This makes it possible to extend the application of the model to lights that are slightly above threshold, but still within the linear operating range of the visual system. A parameter-free prediction of the model proposed by Maloney and Wandell for lights detected by this statistic is tested. The data are in agreement with the prediction.
40 CFR 1066.245 - Response time verification.
Code of Federal Regulations, 2013 CFR
2013-07-01
... dynamometer's automated process to verify response time. Perform this test at two different inertia settings... observed settling response time must be less than 100 milliseconds for each inertia setting. ER15SE11.085 ...
40 CFR 1066.245 - Response time verification.
Code of Federal Regulations, 2012 CFR
2012-07-01
... dynamometer's automated process to verify response time. Perform this test at two different inertia settings... observed settling response time must be less than 100 milliseconds for each inertia setting. ER15SE11.085 ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erickson, Phillip A.; O'Hagan, Ryan; Shumaker, Brent
The Advanced Test Reactor (ATR) has always had a comprehensive procedure to verify the performance of its critical transmitters and sensors, including RTDs, and pressure, level, and flow transmitters. These transmitters and sensors have been periodically tested for response time and calibration verification to ensure accuracy. With implementation of online monitoring techniques at ATR, the calibration verification and response time testing of these transmitters and sensors are verified remotely, automatically, hands off, include more portions of the system, and can be performed at almost any time during process operations. The work was done under a DOE funded SBIR project carriedmore » out by AMS. As a result, ATR is now able to save the manpower that has been spent over the years on manual calibration verification and response time testing of its temperature and pressure sensors and refocus those resources towards more equipment reliability needs. More importantly, implementation of OLM will help enhance the overall availability, safety, and efficiency. Together with equipment reliability programs of ATR, the integration of OLM will also help with I&C aging management goals of the Department of Energy and long-time operation of ATR.« less
Hidden Markov Item Response Theory Models for Responses and Response Times.
Molenaar, Dylan; Oberski, Daniel; Vermunt, Jeroen; De Boeck, Paul
2016-01-01
Current approaches to model responses and response times to psychometric tests solely focus on between-subject differences in speed and ability. Within subjects, speed and ability are assumed to be constants. Violations of this assumption are generally absorbed in the residual of the model. As a result, within-subject departures from the between-subject speed and ability level remain undetected. These departures may be of interest to the researcher as they reflect differences in the response processes adopted on the items of a test. In this article, we propose a dynamic approach for responses and response times based on hidden Markov modeling to account for within-subject differences in responses and response times. A simulation study is conducted to demonstrate acceptable parameter recovery and acceptable performance of various fit indices in distinguishing between different models. In addition, both a confirmatory and an exploratory application are presented to demonstrate the practical value of the modeling approach.
Testing the Race Model Inequality in Redundant Stimuli with Variable Onset Asynchrony
ERIC Educational Resources Information Center
Gondan, Matthias
2009-01-01
In speeded response tasks with redundant signals, parallel processing of the signals is tested by the race model inequality. This inequality states that given a race of two signals, the cumulative distribution of response times for redundant stimuli never exceeds the sum of the cumulative distributions of response times for the single-modality…
Aircraft Fault Detection Using Real-Time Frequency Response Estimation
NASA Technical Reports Server (NTRS)
Grauer, Jared A.
2016-01-01
A real-time method for estimating time-varying aircraft frequency responses from input and output measurements was demonstrated. The Bat-4 subscale airplane was used with NASA Langley Research Center's AirSTAR unmanned aerial flight test facility to conduct flight tests and collect data for dynamic modeling. Orthogonal phase-optimized multisine inputs, summed with pilot stick and pedal inputs, were used to excite the responses. The aircraft was tested in its normal configuration and with emulated failures, which included a stuck left ruddervator and an increased command path latency. No prior knowledge of a dynamic model was used or available for the estimation. The longitudinal short period dynamics were investigated in this work. Time-varying frequency responses and stability margins were tracked well using a 20 second sliding window of data, as compared to a post-flight analysis using output error parameter estimation and a low-order equivalent system model. This method could be used in a real-time fault detection system, or for other applications of dynamic modeling such as real-time verification of stability margins during envelope expansion tests.
Analyzing Response Times in Tests with Rank Correlation Approaches
ERIC Educational Resources Information Center
Ranger, Jochen; Kuhn, Jorg-Tobias
2013-01-01
It is common practice to log-transform response times before analyzing them with standard factor analytical methods. However, sometimes the log-transformation is not capable of linearizing the relation between the response times and the latent traits. Therefore, a more general approach to response time analysis is proposed in the current…
Input-output characterization of an ultrasonic testing system by digital signal analysis
NASA Technical Reports Server (NTRS)
Karaguelle, H.; Lee, S. S.; Williams, J., Jr.
1984-01-01
The input/output characteristics of an ultrasonic testing system used for stress wave factor measurements were studied. The fundamentals of digital signal processing are summarized. The inputs and outputs are digitized and processed in a microcomputer using digital signal processing techniques. The entire ultrasonic test system, including transducers and all electronic components, is modeled as a discrete-time linear shift-invariant system. Then the impulse response and frequency response of the continuous time ultrasonic test system are estimated by interpolating the defining points in the unit sample response and frequency response of the discrete time system. It is found that the ultrasonic test system behaves as a linear phase bandpass filter. Good results were obtained for rectangular pulse inputs of various amplitudes and durations and for tone burst inputs whose center frequencies are within the passband of the test system and for single cycle inputs of various amplitudes. The input/output limits on the linearity of the system are determined.
Controlling silver nanoparticle exposure in algal toxicity testing – A matter of timing
Baun, Anders
2015-01-01
The aquatic ecotoxicity testing of nanoparticles is complicated by unstable exposure conditions resulting from various transformation processes of nanoparticles in aqueous suspensions. In this study, we investigated the influence of exposure timing on the algal test response to silver nanoparticles (AgNPs), by reducing the incubation time and by aging the AgNPs in algal medium prior to testing. The freshwater green algae Pseudokirchneriella subcapitata were exposed to AgNO3, NM-300 K (a representative AgNP) and citrate stabilized AgNPs from two different manufacturers (AgNP1 and AgNP2) in a standard algal growth inhibition test (ISO 8692:2004) for 48 h and a short-term (2 h) 14C-assimilation test. For AgNO3, similar responses were obtained in the two tests, whereas freshly prepared suspensions of citrate stabilized AgNPs were less toxic in the 2-h tests compared to the 48-h tests. The 2-h test was found applicable for dissolved silver, but yielded non-monotonous concentration–response relationships and poor reproducibility for freshly prepared AgNP suspensions. However, when aging AgNPs in algal medium 24 h prior to testing, clear concentration–response patterns emerged and reproducibility increased. Prolonged aging to 48 h increased toxicity in the 2-h tests whereas aging beyond 48 h reduced toxicity. Our results demonstrate that the outcome of algal toxicity testing of AgNPs is highly influenced not only by the test duration, but also by the time passed from the moment AgNPs are added to the test medium. This time-dependency should be considered when nanomaterial dispersion protocols for ecotoxicity testing are developed. PMID:24842597
Random local temporal structure of category fluency responses.
Meyer, David J; Messer, Jason; Singh, Tanya; Thomas, Peter J; Woyczynski, Wojbor A; Kaye, Jeffrey; Lerner, Alan J
2012-04-01
The Category Fluency Test (CFT) provides a sensitive measurement of cognitive capabilities in humans related to retrieval from semantic memory. In particular, it is widely used to assess progress of cognitive impairment in patients with dementia. Previous research shows that, in the first approximation, the intensity of tested individuals' responses within a standard 60-s test period decays exponentially with time, with faster decay rates for more cognitively impaired patients. Such decay rate can then be viewed as a global (macro) diagnostic parameter of each test. In the present paper we focus on the statistical properties of the properly de-trended time intervals between consecutive responses (inter-call times) in the Category Fluency Test. In a sense, those properties reflect the local (micro) structure of the response generation process. We find that a good approximation for the distribution of the de-trended inter-call times is provided by the Weibull Distribution, a probability distribution that appears naturally in this context as a distribution of a minimum of independent random quantities and is the standard tool in industrial reliability theory. This insight leads us to a new interpretation of the concept of "navigating a semantic space" via patient responses.
ERIC Educational Resources Information Center
Israel, Richard G.
A study determined the effects of fatigue produced in the upper extremities on the reaction time, movement time, and response time of the lower extremities in 30 male subjects, 19-25 years old. Each subject participated in a 10 trial practice session one day prior to the experiment and immediately preceding the pre-test. The pre-test consisted of…
Spinning Reserve From Hotel Load Response: Initial Progress
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kueck, John D; Kirby, Brendan J
2008-11-01
This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby andmore » Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.« less
Reliability of Autonomic Responses and Malaise Across Multiple Motion Sickness Stimulation Tests
NASA Technical Reports Server (NTRS)
Stout, Cynthia S.; Toscano, William B.; Cowings, Patricia S.
1993-01-01
There is general agreement that a high degree of variability exists between subjects in their autonomic nervous system responses to motion sickness stimulation. Additionally, a paucity of data exists that examines the variability within an individual across repeated motion sickness tests. Investigators have also examined the relationship of autonomic responses to motion sickness development. These investigations have used analyses at discrete points in time to describe this relationship. This approach fails to address the time course of autonomic responses and malaise development throughout the motion sickness test. Our objectives were to examine the reliability of autonomic responses and malaise using the final minute of the motion sickness test across five testing occasions, to examine the reliability of the change in autonomic responses and the change in malaise across five testing occasions, and to examine the relationship between changes in autonomic responses and changes in malaise level across the entire motion sickness test. Our results indicate that, based on the final minute of testing, the autonomic responses of heart rate, blood volume pulse, and respiration rate are moderately stable across multiple tests. Changes in heart rate, blood volume pulse, respiration rate, and malaise throughout the test duration were less stable across the tests. We attribute this instability to variations in individual susceptibility and the error associated with estimating a measure of autonomic gain.
Holden, Ronald R; Lambert, Christine E
2015-12-01
Van Hooft and Born (Journal of Applied Psychology 97:301-316, 2012) presented data challenging both the correctness of a congruence model of faking on personality test items and the relative merit (i.e., effect size) of response latencies for identifying fakers. We suggest that their analysis of response times was suboptimal, and that it followed neither from a congruence model of faking nor from published protocols on appropriately filtering the noise in personality test item answering times. Using new data and following recommended analytic procedures, we confirmed the relative utility of response times for identifying personality test fakers, and our obtained results, again, reinforce a congruence model of faking.
Tilt angles and positive response of head-up tilt test in children with orthostatic intolerance.
Lin, Jing; Wang, Yuli; Ochs, Todd; Tang, Chaoshu; Du, Junbao; Jin, Hongfang
2015-01-01
This study aimed at examining three tilt angle-based positive responses and the time to positive response in a head-up tilt test for children with orthostatic intolerance, and the psychological fear experienced at the three angles during head-up tilt test. A total of 174 children, including 76 boys and 98 girls, aged from 4 to 18 years old (mean 11.3±2.8 years old), with unexplained syncope, were randomly divided into three groups, to undergo head-up tilt test at the angles of 60°, 70° and 80°, respectively. The diagnostic rates and times were analysed, and Wong-Baker face pain rating scale was used to access the children's psychological fear. There were no significant differences in diagnostic rates of postural orthostatic tachycardia syndrome and vasovagal syncope at different tilt angles during the head-up tilt test (p>0.05). There was a significant difference, however, in the psychological fear at different tilt angles utilising the Kruskal-Wallis test (χ2=36.398, p<0.01). It was mildest at tilt angle 60° utilising the Kolmogorov-Smirnov test (p<0.01). A positive rank correlation was found between the psychological fear and the degree of tilt angle (r(s)=0.445, p<0.01). Positive response appearance time was 15.1±14.0 minutes at 60° for vasovagal syncope children. There was no significant difference in the time to positive response, at different tilt angles during the head-up tilt test for vasovagal syncope or for postural orthostatic tachycardia syndrome. Hence, it is suggested that a tilt angle of 60° and head-up tilt test time of 45 minutes should be suitable for children with vasovagal syncope.
Affiliation and aggression as related to gender in domestic chicks (Gallus gallus).
Vallortigara, G
1992-03-01
Social discrimination in male and female domestic chicks (Gallus gallus) was investigated by using (a) latencies of approach response, (b) simultaneous free choice, and (c) intersubject aggressive-pecking tests. In approach-response tests, females showed shorter latencies when tested with cagemates than when tested with strangers, whereas males showed shorter latencies when tested with strangers than when tested with cagemates. In simultaneous-choice tests, females spent more time near a cagemate, whereas males spent more time near a strange chick. In aggressive-pecking tests, both sexes pecked more at strangers than at cagemates; aggressive pecking at strangers, however, was higher in males than in females. It is argued that gender effects in social discrimination can be accounted for in terms of stronger social attachment in females and aggressive responses in males.
Chen, R; Hahn, C E W; Farmery, A D
2012-08-15
The development of a methodology for testing the time response, linearity and performance characteristics of ultra fast fibre optic oxygen sensors in the liquid phase is presented. Two standard medical paediatric oxygenators are arranged to provide two independent extracorporeal circuits. Flow from either circuit can be diverted over the sensor under test by means of a system of rapid cross-over solenoid valves exposing the sensor to an abrupt change in oxygen partial pressure, P O2. The system is also capable of testing the oxygen sensor responses to changes in temperature, carbon dioxide partial pressure P CO2 and pH in situ. Results are presented for a miniature fibre optic oxygen sensor constructed in-house with a response time ≈ 50 ms and a commercial fibre optic sensor (Ocean Optics Foxy), when tested in flowing saline and stored blood. Copyright © 2012 Elsevier B.V. All rights reserved.
Impaired Response Selection During Stepping Predicts Falls in Older People-A Cohort Study.
Schoene, Daniel; Delbaere, Kim; Lord, Stephen R
2017-08-01
Response inhibition, an important executive function, has been identified as a risk factor for falls in older people. This study investigated whether step tests that include different levels of response inhibition differ in their ability to predict falls and whether such associations are mediated by measures of attention, speed, and/or balance. A cohort study with a 12-month follow-up was conducted in community-dwelling older people without major cognitive and mobility impairments. Participants underwent 3 step tests: (1) choice stepping reaction time (CSRT) requiring rapid decision making and step initiation; (2) inhibitory choice stepping reaction time (iCSRT) requiring additional response inhibition and response-selection (go/no-go); and (3) a Stroop Stepping Test (SST) under congruent and incongruent conditions requiring conflict resolution. Participants also completed tests of processing speed, balance, and attention as potential mediators. Ninety-three of the 212 participants (44%) fell in the follow-up period. Of the step tests, only components of the iCSRT task predicted falls in this time with the relative risk per standard deviation for the reaction time (iCSRT-RT) = 1.23 (95%CI = 1.10-1.37). Multiple mediation analysis indicated that the iCSRT-RT was independently associated with falls and not mediated through slow processing speed, poor balance, or inattention. Combined stepping and response inhibition as measured in a go/no-go test stepping paradigm predicted falls in older people. This suggests that integrity of the response-selection component of a voluntary stepping response is crucial for minimizing fall risk. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
van der Linden, Wim J.
2011-01-01
It is shown how the time limit on a test can be set to control the probability of a test taker running out of time before completing it. The probability is derived from the item parameters in the lognormal model for response times. Examples of curves representing the probability of running out of time on a test with given parameters as a function…
NASA Astrophysics Data System (ADS)
Wei, Jing; Zhang, Lisheng; Zhao, Chong; Feng, Wenping; Sun, Ping; Chang, Yaqing
2016-11-01
Complex marine benthic environments shape a number of ecologically important behaviors in sea urchins, including covering and righting behaviors. The present study correlated covering and righting behaviors to a series of fitness-related traits in sea urchins. Righting response time of Glyptocidaris crenularis was significantly positively correlated with body size, but significantly negatively correlated with food consumption. Covering behavior was not significantly correlated with test diameter, test height or body weight, but covering response time was negatively correlated with body weight. A significantly negative correlation was found between righting response time and covering response time. Glyptocidaris crenularis showed a significantly positive correlation in covering response time with and without exposure to poured sand, but no significance in covering ability (number of shells used to cover). The present study provides new insight into internal mechanisms and evolutionary drives of covering and righting behaviors of sea urchins.
Posterior Predictive Checks for Conditional Independence between Response Time and Accuracy
ERIC Educational Resources Information Center
Bolsinova, Maria; Tijmstra, Jesper
2016-01-01
Conditional independence (CI) between response time and response accuracy is a fundamental assumption of many joint models for time and accuracy used in educational measurement. In this study, posterior predictive checks (PPCs) are proposed for testing this assumption. These PPCs are based on three discrepancy measures reflecting different…
Modeling Response Signal and Response Time Data
ERIC Educational Resources Information Center
Ratcliff, Roger
2006-01-01
The diffusion model (Ratcliff, 1978) and the leaky competing accumulator model (LCA, Usher & McClelland, 2001) were tested against two-choice data collected from the same subjects with the standard response time procedure and the response signal procedure. In the response signal procedure, a stimulus is presented and then, at one of a number of…
Winston, Richard B.; Shapiro, Allen M.
2007-01-01
The BAT3 Analyzer provides real-time display and interpretation of fluid pressure responses and flow rates measured during geochemical sampling, hydraulic testing, or tracer testing conducted with the Multifunction Bedrock-Aquifer Transportable Testing Tool (BAT3) (Shapiro, 2007). Real-time display of the data collected with the Multifunction BAT3 allows the user to ensure that the downhole apparatus is operating properly, and that test procedures can be modified to correct for unanticipated hydraulic responses during testing. The BAT3 Analyzer can apply calibrations to the pressure transducer and flow meter data to display physically meaningful values. Plots of the time-varying data can be formatted for a specified time interval, and either saved to files, or printed. Libraries of calibrations for the pressure transducers and flow meters can be created, updated and reloaded to facilitate the rapid set up of the software to display data collected during testing with the Multifunction BAT3. The BAT3 Analyzer also has the functionality to estimate calibrations for pressure transducers and flow meters using data collected with the Multifunction BAT3 in conjunction with corroborating check measurements. During testing with the Multifunction BAT3, and also after testing has been completed, hydraulic properties of the test interval can be estimated by comparing fluid pressure responses with model results; a variety of hydrogeologic conceptual models of the formation are available for interpreting fluid-withdrawal, fluid-injection, and slug tests.
Using chaotic forcing to detect damage in a structure
Moniz, L.; Nichols, J.; Trickey, S.; Seaver, M.; Pecora, D.; Pecora, L.
2005-01-01
In this work we develop a numerical test for Holder continuity and apply it and another test for continuity to the difficult problem of detecting damage in structures. We subject a thin metal plate with incremental damage to the plate changes, its filtering properties, and therefore the phase space trajectories of the response chaotic excitation of various bandwidths. Damage to the plate changes its filtering properties and therefore the phase space of the response. Because the data are multivariate (the plate is instrumented with multiple sensors) we use a singular value decomposition of the set of the output time series to reduce the embedding dimension of the response time series. We use two geometric tests to compare an attractor reconstructed from data from an undamaged structure to that reconstructed from data from a damaged structure. These two tests translate to testing for both generalized and differentiable synchronization between responses. We show loss of synchronization of responses with damage to the structure. ?? 2005 American Institute of Physics.
Using chaotic forcing to detect damage in a structure.
Moniz, L.; Nichols, J.; Trickey, S.; Seaver, M.; Pecora, D.; Pecora, L.
2005-01-01
In this work we develop a numerical test for Holder continuity and apply it and another test for continuity to the difficult problem of detecting damage in structures. We subject a thin metal plate with incremental damage to the plate changes, its filtering properties, and therefore the phase space trajectories of the response chaotic excitation of various bandwidths. Damage to the plate changes its filtering properties and therefore the phase space of the response. Because the data are multivariate (the plate is instrumented with multiple sensors) we use a singular value decomposition of the set of the output time series to reduce the embedding dimension of the response time series. We use two geometric tests to compare an attractor reconstructed from data from an undamaged structure to that reconstructed from data from a damaged structure. These two tests translate to testing for both generalized and differentiable synchronization between responses. We show loss of synchronization of responses with damage to the structure.
Gooch, Cynthia M.; Stern, Yaakov; Rakitin, Brian C.
2009-01-01
The effect of aging on interval timing was examined using a choice time production task, which required participants to choose a key response based on the location of the stimulus, but to delay responding until after a learned time interval. Experiment 1 varied attentional demands of the response choice portion of the task by varying difficulty of stimulus-response mapping. Choice difficulty affected temporal accuracy equally in both age groups, but older participants’ response latencies were more variable under more difficult response choice conditions. Experiment 2 tested the contribution of long-term memory to differences in choice time production between age groups over 3 days of testing. Direction of errors in time production between the two age groups diverged over the 3 sessions, but variability did not differ. Results from each experiment separately show age-related changes to attention and memory in temporal processing using different measures and manipulations in the same task. PMID:19132578
New developments in supra-threshold perimetry.
Henson, David B; Artes, Paul H
2002-09-01
To describe a series of recent enhancements to supra-threshold perimetry. Computer simulations were used to develop an improved algorithm (HEART) for the setting of the supra-threshold test intensity at the beginning of a field test, and to evaluate the relationship between various pass/fail criteria and the test's performance (sensitivity and specificity) and how they compare with modern threshold perimetry. Data were collected in optometric practices to evaluate HEART and to assess how the patient's response times can be analysed to detect false positive response errors in visual field test results. The HEART algorithm shows improved performance (reduced between-eye differences) over current algorithms. A pass/fail criterion of '3 stimuli seen of 3-5 presentations' at each test location reduces test/retest variability and combines high sensitivity and specificity. A large percentage of false positive responses can be detected by comparing their latencies to the average response time of a patient. Optimised supra-threshold visual field tests can perform as well as modern threshold techniques. Such tests may be easier to perform for novice patients, compared with the more demanding threshold tests.
Sangenstedt, Susanne; Jaljuli, Iman; Sachser, Norbert; Kaiser, Sylvia
2017-04-01
The early social environment can profoundly affect behavioral and physiological phenotypes. We investigated how male wild cavy offspring, whose mothers had either lived in a stable (SE) or an unstable social environment (UE) during pregnancy and lactation, differed in their anxiety-like behavior and stress responsiveness. At two different time points in life, we tested the offspring's anxiety-like behavior in a dark-light test and their endocrine reaction to challenge in a cortisol reactivity test. Furthermore, we analyzed whether individual traits remained stable over time. There was no effect of the early social environment on anxiety-like behavior and stress responsiveness. However, at an individual level, anxiety-like behavior was stable over time in UE- but not in SE-sons. Stress responsiveness, in turn, was rather inconsistent in UE-sons and temporally stable in SE-sons. Conclusively, we showed for the first time that the early social environment differentially shapes the stability of behavioral and endocrine traits. At first glance, these results may be surprising, but they can be explained by the different functions anxiety-like behavior and stress responsiveness have. Copyright © 2017 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Bergert, F. Bryan; Nosofsky, Robert M.
2007-01-01
The authors develop and test generalized versions of take-the-best (TTB) and rational (RAT) models of multiattribute paired-comparison inference. The generalized models make allowances for subjective attribute weighting, probabilistic orders of attribute inspection, and noisy decision making. A key new test involves a response-time (RT)…
Modeling Information Accumulation in Psychological Tests Using Item Response Times
ERIC Educational Resources Information Center
Ranger, Jochen; Kuhn, Jörg-Tobias
2015-01-01
In this article, a latent trait model is proposed for the response times in psychological tests. The latent trait model is based on the linear transformation model and subsumes popular models from survival analysis, like the proportional hazards model and the proportional odds model. Core of the model is the assumption that an unspecified monotone…
ERIC Educational Resources Information Center
Sung, Kyongje
2008-01-01
Participants searched a visual display for a target among distractors. Each of 3 experiments tested a condition proposed to require attention and for which certain models propose a serial search. Serial versus parallel processing was tested by examining effects on response time means and cumulative distribution functions. In 2 conditions, the…
Response Time Differences between Computers and Tablets
ERIC Educational Resources Information Center
Kong, Xiaojing; Davis, Laurie Laughlin; McBride, Yuanyuan; Morrison, Kristin
2018-01-01
Item response time data were used in investigating the differences in student test-taking behavior between two device conditions: computer and tablet. Analyses were conducted to address the questions of whether or not the device condition had a differential impact on rapid guessing and solution behaviors (with response time effort used as an…
van Maanen, Leendert; de Jong, Ritske; van Rijn, Hedderik
2014-01-01
When multiple strategies can be used to solve a type of problem, the observed response time distributions are often mixtures of multiple underlying base distributions each representing one of these strategies. For the case of two possible strategies, the observed response time distributions obey the fixed-point property. That is, there exists one reaction time that has the same probability of being observed irrespective of the actual mixture proportion of each strategy. In this paper we discuss how to compute this fixed-point, and how to statistically assess the probability that indeed the observed response times are generated by two competing strategies. Accompanying this paper is a free R package that can be used to compute and test the presence or absence of the fixed-point property in response time data, allowing for easy to use tests of strategic behavior. PMID:25170893
A Conditional Joint Modeling Approach for Locally Dependent Item Responses and Response Times
ERIC Educational Resources Information Center
Meng, Xiang-Bin; Tao, Jian; Chang, Hua-Hua
2015-01-01
The assumption of conditional independence between the responses and the response times (RTs) for a given person is common in RT modeling. However, when the speed of a test taker is not constant, this assumption will be violated. In this article we propose a conditional joint model for item responses and RTs, which incorporates a covariance…
NASA Technical Reports Server (NTRS)
Cotton, Will; Liechty, John
2015-01-01
This paper describes a testing methodology undertaken on the Facilities Development and Operations Contract (FDOC) by Lockheed Martin. The methodology was defined with the intent of reducing project schedule time to enable NASA's Johnson Space Center (JSC) to be able to deliver the Mission Control Center (MCC) 21 project as quickly as possible. 21 represents the 21st century where NASA JSC is updating its control center with new technology and operational concepts in order to support NASA customers wanting to use control center assets to support space vehicle operations. In collaboration with the NASA customer, a new test concept was conceived early during MCC21 project planning with the goal of reducing project delivery time. One enabler that could help reduce delivery time was testing. Within the project, testing was performed by two entities, software development responsible for subsystem testing and system test responsible for system integration testing. The MCC21 project took a deliberate review of testing to determine how it could be performed differently to realize an overall reduction in test time to support the goal of a more rapid project delivery.
Modeling Student Test-Taking Motivation in the Context of an Adaptive Achievement Test
ERIC Educational Resources Information Center
Wise, Steven L.; Kingsbury, G. Gage
2016-01-01
This study examined the utility of response time-based analyses in understanding the behavior of unmotivated test takers. For the data from an adaptive achievement test, patterns of observed rapid-guessing behavior and item response accuracy were compared to the behavior expected under several types of models that have been proposed to represent…
Molenaar, Dylan; Tuerlinckx, Francis; van der Maas, Han L J
2015-01-01
A generalized linear modeling framework to the analysis of responses and response times is outlined. In this framework, referred to as bivariate generalized linear item response theory (B-GLIRT), separate generalized linear measurement models are specified for the responses and the response times that are subsequently linked by cross-relations. The cross-relations can take various forms. Here, we focus on cross-relations with a linear or interaction term for ability tests, and cross-relations with a curvilinear term for personality tests. In addition, we discuss how popular existing models from the psychometric literature are special cases in the B-GLIRT framework depending on restrictions in the cross-relation. This allows us to compare existing models conceptually and empirically. We discuss various extensions of the traditional models motivated by practical problems. We also illustrate the applicability of our approach using various real data examples, including data on personality and cognitive ability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ringgenberg, P.D.; Burris, W.J.
1988-06-28
A method is described of flow testing a formation in a wellbore, comprising: providing a testing string including at least one annulus pressure responsive tool bore closure valve; providing a packer and setting the packer in the wellbore to seal thereacross; running the testing string into the wellbore with the tool bore closure valve in an open position; stinging into the set packer with the bottom of the testing string; increasing pressure a first time in the wellbore annulus around the testing string and above the set packer without cycling the tool bore closure valve; reducing pressure in the wellboremore » annulus; closing the tool bore closure valve responsive to the pressure reduction; increasing pressure a second time in the wellbore annulus; reopening the tool bore closure valve responsive to the second increase; and flowing fluids from the formation through the reopened tool bore closure valve.« less
ERIC Educational Resources Information Center
Swygert, Kimberly A.
In this study, data from an operational computerized adaptive test (CAT) were examined in order to gather information concerning item response times in a CAT environment. The CAT under study included multiple-choice items measuring verbal, quantitative, and analytical reasoning. The analyses included the fitting of regression models describing the…
ERIC Educational Resources Information Center
Davison, Mark L.; Semmes, Robert; Huang, Lan; Close, Catherine N.
2012-01-01
Data from 181 college students were used to assess whether math reasoning item response times in computerized testing can provide valid and reliable measures of a speed dimension. The alternate forms reliability of the speed dimension was .85. A two-dimensional structural equation model suggests that the speed dimension is related to the accuracy…
Chen, Chien-Liang; Tang, Jing-Shia; Li, Ping-Chia; Chou, Pi-Ling
2015-01-01
This study compared the immediate effects of smoking on cardiorespiratory responses to dynamic arm and leg exercises. This randomized crossover study recruited 14 college students. Each participant underwent two sets of arm-cranking (AC) and leg-cycling (LC) exercise tests. The testing sequences of the control trial (participants refrained from smoking for 8 h before testing) and the experimental trial (participants smoked two cigarettes immediately before testing) were randomly chosen. We observed immediate changes in pulmonary function and heart rate variability after smoking and before the exercise test. The participants then underwent graded exercise tests of their arms and legs until reaching exhaustion. We compared the peak work achieved and time to exhaustion during the exercise tests with various cardiorespiratory indices [i.e., heart rate, oxygen consumption (VO2), minute ventilation (VE)]. The differences between the smoking and control trials were calculated using paired t-tests. For the exercise test periods, VO2, heart rate, and VE values were calculated at every 10% increment of the maximal effort time. The main effects of the time and trial, as well as their trial-by-time (4 × 10) interaction effects on the outcome measures, were investigated using repeated measure ANOVA with trend analysis. 5 min after smoking, the participants exhibited reduced forced vital capacities and forced expiratory volumes in the first second (P < 0.05), in addition to elevated resting heart rates (P < 0.001). The high-frequency, low-frequency, and the total power of the heart rate variability were also reduced (P < 0.05) at rest. For the exercise test periods, smoking reduced the time to exhaustion (P = 0.005) and the ventilatory threshold (P < 0.05) in the LC tests, whereas no significant effects were observed in the AC tests. A trend analysis revealed a significant trial-by-time interaction effect for heart rate, VO2, and VE during the graded exercise test (all P < 0.001). Lower VO2 and VE levels were exhibited in the exercise response of the smoking trial than in those of the control LC trials, whereas no discernable inter-trial difference was observed in the AC trials. Moreover, the differences in heart rate and VE response between the LC and AC exercises were significantly smaller after the participants smoked. This study verified that smoking significantly decreased performance and cardiorespiratory responses to leg exercises. However, the negative effects of smoking on arm exercise performance were not as pronounced.
Allum, John H J; Cleworth, T; Honegger, Flurin
2016-07-01
We investigated how response asymmetries and deficit side response amplitudes for head accelerations used clinically to test the vestibular ocular reflex (VOR) are correlated with caloric canal paresis (CP) values. 30 patients were examined at onset of an acute unilateral peripheral vestibular deficit (aUPVD) and 3, 6, and 13 weeks later with three different VOR tests: caloric, rotating chair (ROT), and video head impulse tests (vHIT). Response changes over time were fitted with an exponential decay model and compared with using linear regression analysis. Recovery times (to within 10% of steady state) were similar for vHIT-asymmetry and CP (>10 weeks) but shorter for ROT asymmetry (<4 weeks). Regressions with CP were similar (vHIT asymmetry, R = 0.68, ROT, R = 0.62). Responses to the deficit side were also equally well correlated with CP values (R = 0.71). Specificity for vHIT and 20 degrees/s ROT deficit side responses was 100% in comparison to CP values, sensitivity was 74% for vHIT, 75% for ROT. A decrease in normal side responses occurred for ROT but not for vHIT at 3 weeks. Normal side responses were weekly correlated with CP for ROT (R = 0.49) but not for vHIT (R = 0.17). These results indicate that vHIT deficit side VOR gains are slightly better correlated with CP values than ROT, probably because of similar recovery time courses of vHIT and caloric responses and the lack of normal side vHIT changes. However, specificity and sensitivity is the same for vHIT and ROT tests.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-09
... Number of Total Responses: 100. Estimated Time per Response: 75 minutes. Estimated Total Burden Hours: 125. Record Keeping: Estimated Number of Record Keepers: 100. Estimated Time per Record Keeper: 60...
Study of Laser Reflectivity on Skin
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oidor-Garcia, J. J. J.; Trevino-Palacios, C. G.
2008-08-11
The response to the light on the skin can be manifested as temperature increase or creation of biochemical byproducts, in which further studies are required to asset the light effect. This response changes the average response over time and can produce discrepancies between similar studies. In this work we present a Low Level Laser Therapy (LLLT) study with feedback. We study the time response reflectivity of a 980 nm laser diode of 25 mW modulated at frequencies close to 40 kHz and detect the reflected light on a silicon photodiode, finding no direct correlation between different test points or individuals,more » while finding reproducible responses within the same individual and test point.« less
Computer-aided testing of pilot response to critical in-flight events
NASA Technical Reports Server (NTRS)
Giffin, W. C.; Rockwell, T. H.
1984-01-01
This research on pilot response to critical in-flight events employs a unique methodology including an interactive computer-aided scenario-testing system. Navigation displays, instrument-panel displays, and assorted textual material are presented on a touch-sensitive CRT screen. Problem diagnosis scenarios, destination-diversion scenarios and combined destination/diagnostic tests are available. A complete time history of all data inquiries and responses is maintained. Sample results of diagnosis scenarios obtained from testing 38 licensed pilots are presented and discussed.
ERIC Educational Resources Information Center
van der Linden, Wim J.
2011-01-01
A critical component of test speededness is the distribution of the test taker's total time on the test. A simple set of constraints on the item parameters in the lognormal model for response times is derived that can be used to control the distribution when assembling a new test form. As the constraints are linear in the item parameters, they can…
Tollitt, James; Flanagan, Emma; McCorkindale, Sheila; Glynn-Atkins, Sam; Emmett, Lauren; Darby, Denise; Ritchie, James; Bennett, Brandon; Sinha, Smeeta; Poulikakos, Dimitrios
2018-04-28
Acute kidney injury (AKI) detected in primary care is associated with increased morbidity and mortality. AKI electronic alerts (e-alerts) and educational programmes have recently been implemented but their contribution to improve AKI care is unknown. This project aimed to improve response to AKI detected in primary care and used a factorial design to evaluate the impact of the UK National Health Service (NHS) AKI e-alert and AKI educational outreach sessions on time to response to primary care AKI stages 2 and 3 between April and August 2016. A total of 46 primary care practices were randomized into four groups. A 2 × 2 factorial design exposed each group to different combinations of two interventions. The primary outcome was 'time to repeat test' or hospitalization following AKI e-alert for stages 2 and 3. Yates algorithm was used to evaluate the impact of each intervention. Time to response and mortality pre- and post-intervention were analysed using Mann-Whitney U test and chi-square test respectively. The factorial design included two interventions: an AKI educational outreach programme and the NHS AKI e-alerts. 1807 (0.8%) primary care blood tests demonstrated AKI 1-3 (78.3% stage 1, 14.8% stage 2, 6.9% stage 3). There were 391 stage 2 and 3 events from 251 patients. E-alerts demonstrated a reduction in mean response time (-29 hours). Educational outreach had a smaller effect (-3 hours). Median response time to AKI 2 and 3 pre- and post-interventions was 27 hours versus 16 hours respectively (P = 0.037). Stage 2 and 3 event-related 30-day all-cause mortality decreased following the interventions (15.6% versus 3.9% P = 0.036). AKI e-alerts in primary care hasten response to AKI 2 and 3 and reduce all-cause mortality. Educational outreach sessions further improve response time.
Ferm, Inga; Lightfoot, Guy; Stevens, John
2013-06-01
To evaluate the auditory brainstem response (ABR) amplitudes evoked by tone pip and narrowband chirp (NB CE-Chirp) stimuli when testing post-screening newborns and to determine the difference in estimated hearing level correction values. Tests were performed with tone pips and NB CE-Chirps at 4 kHz or 1 kHz. The response amplitude, response quality (Fmp), and residual noise were compared for both stimuli. Thirty babies (42 ears) who passed our ABR discharge criterion at 4 kHz following referral from their newborn hearing screen. Overall, NB CE-Chirp responses were 64% larger than the tone pip responses, closer to those evoked by clicks. Fmp was significantly higher for NB CE-Chirps. It is anticipated that there could be significant reductions in test time for the same signal to noise ratio by using NB CE-Chirps when testing newborns. This effect may vary in practice and is likely to be most beneficial for babies with low amplitude ABR responses. We propose that the ABR nHL threshold to eHL correction for NB CE-Chirps should be approximately 5 dB less than the corrections for tone pips at 4 and 1 kHz.
Item Response Theory Models for Performance Decline during Testing
ERIC Educational Resources Information Center
Jin, Kuan-Yu; Wang, Wen-Chung
2014-01-01
Sometimes, test-takers may not be able to attempt all items to the best of their ability (with full effort) due to personal factors (e.g., low motivation) or testing conditions (e.g., time limit), resulting in poor performances on certain items, especially those located toward the end of a test. Standard item response theory (IRT) models fail to…
NASA Technical Reports Server (NTRS)
Bragg-Sitton, S. M.; Webster, K. L.
2007-01-01
Nonnuclear testing can be a valuable tool in the development of an in-space nuclear power or propulsion system. In a nonnuclear test facility, electric heaters are used to simulate heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and full nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response and response characteristics, and assess potential design improvements with a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE 100a heat pipe cooled, electrically heated reactor and heat exchanger hardware. This Technical Memorandum discusses the status of the planned dynamic test methodology for implementation in the direct-drive gas-cooled reactor testing and assesses the additional instrumentation needed to implement high-fidelity dynamic testing.
Petscher, Yaacov; Mitchell, Alison M; Foorman, Barbara R
2015-01-01
A growing body of literature suggests that response latency, the amount of time it takes an individual to respond to an item, may be an important factor to consider when using assessment data to estimate the ability of an individual. Considering that tests of passage and list fluency are being adapted to a computer administration format, it is possible that accounting for individual differences in response times may be an increasingly feasible option to strengthen the precision of individual scores. The present research evaluated the differential reliability of scores when using classical test theory and item response theory as compared to a conditional item response model which includes response time as an item parameter. Results indicated that the precision of student ability scores increased by an average of 5 % when using the conditional item response model, with greater improvements for those who were average or high ability. Implications for measurement models of speeded assessments are discussed.
Petscher, Yaacov; Mitchell, Alison M.; Foorman, Barbara R.
2016-01-01
A growing body of literature suggests that response latency, the amount of time it takes an individual to respond to an item, may be an important factor to consider when using assessment data to estimate the ability of an individual. Considering that tests of passage and list fluency are being adapted to a computer administration format, it is possible that accounting for individual differences in response times may be an increasingly feasible option to strengthen the precision of individual scores. The present research evaluated the differential reliability of scores when using classical test theory and item response theory as compared to a conditional item response model which includes response time as an item parameter. Results indicated that the precision of student ability scores increased by an average of 5 % when using the conditional item response model, with greater improvements for those who were average or high ability. Implications for measurement models of speeded assessments are discussed. PMID:27721568
A comparison of visual inspection time measures in children with cerebral palsy.
Kaufman, Jacqueline N; Donders, Jacobus; Warschausky, Seth
2014-05-01
This study examined the performance of children with and without cerebral palsy on two inspection time (IT) tests, as accessible nonspeeded response measures of cognitive processing speed. Participants, ages 8 to 16, included 66 children with congenital CP and 119 typically developing peers. Measures were two visual IT tasks with identical target stimuli but differential response strategies either via a traditional dual-key method or with an assistive technology pressure switch interface and response option scanning. The CP group had slower IT than the control group independent of test version. Log transformations were used to address skew, and transformed mean intraclass correlations showed moderate agreement between test versions for both participant groups. Bland-Altman plots showed that at higher mean IT thresholds, greater discrepancies between test version scores were observed. Findings support the feasibility of developing tests that reduce speeded motor response demands. Future test development should incorporate increased gradations of difficulty at the extremes of neuropsychological functioning to more accurately assess the performance of individuals whose conditions are associated with atypical performance levels. (c) 2014 APA, all rights reserved.
NASA Astrophysics Data System (ADS)
Dong, Dai; Li, Xiaoning
2015-03-01
High-pressure solenoid valve with high flow rate and high speed is a key component in an underwater driving system. However, traditional single spool pilot operated valve cannot meet the demands of both high flow rate and high speed simultaneously. A new structure for a high pressure solenoid valve is needed to meet the demand of the underwater driving system. A novel parallel-spool pilot operated high-pressure solenoid valve is proposed to overcome the drawback of the current single spool design. Mathematical models of the opening process and flow rate of the valve are established. Opening response time of the valve is subdivided into 4 parts to analyze the properties of the opening response. Corresponding formulas to solve 4 parts of the response time are derived. Key factors that influence the opening response time are analyzed. According to the mathematical model of the valve, a simulation of the opening process is carried out by MATLAB. Parameters are chosen based on theoretical analysis to design the test prototype of the new type of valve. Opening response time of the designed valve is tested by verifying response of the current in the coil and displacement of the main valve spool. The experimental results are in agreement with the simulated results, therefore the validity of the theoretical analysis is verified. Experimental opening response time of the valve is 48.3 ms at working pressure of 10 MPa. The flow capacity test shows that the largest effective area is 126 mm2 and the largest air flow rate is 2320 L/s. According to the result of the load driving test, the valve can meet the demands of the driving system. The proposed valve with parallel spools provides a new method for the design of a high-pressure valve with fast response and large flow rate.
USDA-ARS?s Scientific Manuscript database
The internal consistency of the Test of Variables of Attention (TOVA) was examined in a cohort of 6- to 12-year-old children (N = 63) strictly diagnosed with ADHD. The internal consistency of errors of omission (OMM), errors of commission (COM), response time (RT), and response time variability (RTV...
Chen, David D; Pei, Laura; Chan, John S Y; Yan, Jin H
2012-10-01
Recent research using deliberate amplification of spatial errors to increase motor learning leads to the question of whether amplifying temporal errors may also facilitate learning. We investigated transfer effects caused by manipulating temporal constraints on learning a two-choice reaction time (CRT) task with varying degrees of stimulus-response compatibility. Thirty-four participants were randomly assigned to one of the three groups and completed 120 trials during acquisition. For every fourth trial, one group was instructed to decrease CRT by 50 msec. relative to the previous trial and a second group was instructed to increase CRT by 50 msec. The third group (the control) was told not to change their responses. After a 5-min. break, participants completed a 40-trial no-feedback transfer test. A 40-trial delayed transfer test was administered 24 hours later. During acquisition, the Decreased Reaction Time group responded faster than the two other groups, but this group also made more errors than the other two groups. In the 5-min. delayed test (immediate transfer), the Decreased Reaction Time group had faster reaction times than the other two groups, while for the 24-hr. delayed test (delayed transfer), both the Decreased Reaction Time group and Increased Reaction Time group had significantly faster reaction times than the control. For delayed transfer, both Decreased and Increased Reaction Time groups reacted significantly faster than the control group. Analyses of error scores in the transfer tests indicated revealed no significant group differences. Results were discussed with regard to the notion of practice variability and goal-setting benefits.
Hines, Jarrod C.; Touron, Dayna R.; Hertzog, Christopher
2009-01-01
The current study evaluated a metacognitive account of study time allocation, which argues that metacognitive monitoring of recognition test accuracy and latency influences subsequent strategic control and regulation. We examined judgments of learning (JOLs), recognition test confidence judgments (CJs), and subjective response time (RT) judgments by younger and older adults in an associative recognition task involving two study-test phases, with self-paced study in phase 2. Multilevel regression analyses assessed the degree to which age and metacognitive variables predicted phase 2 study time independent of actual test accuracy and RT. Outcomes supported the metacognitive account – JOLs and CJs predicted study time independent of recognition accuracy. For older adults with errant RT judgments, subjective retrieval fluency influenced response confidence as well as (mediated through confidence) subsequent study time allocation. Older adults studied items longer which had been assigned lower CJs, suggesting no age deficit in using memory monitoring to control learning. PMID:19485662
Modeling Nonignorable Missing Data in Speeded Tests
ERIC Educational Resources Information Center
Glas, Cees A. W.; Pimentel, Jonald L.
2008-01-01
In tests with time limits, items at the end are often not reached. Usually, the pattern of missing responses depends on the ability level of the respondents; therefore, missing data are not ignorable in statistical inference. This study models data using a combination of two item response theory (IRT) models: one for the observed response data and…
Subjective response to sonic booms having different shapes, rise times, and durations
NASA Technical Reports Server (NTRS)
Mccurdy, David A.
1994-01-01
Two laboratory experiments were conducted to quantify the subjective response of people to simulated outdoor sonic booms having different pressure signatures. The specific objectives of the experiments were to compare subjective response to sonic booms when described in terms of 'loudness' and 'annoyance'; to determine the ability of various noise metrics to predict subjective response to sonic booms; to determine the effects on subjective response of rise time, duration, and level; and to compare the subjective response to 'N-wave' sonic boom signatures with the subjective response to 'minimized' sonic boom signatures. The experiments were conducted in a computer-controlled, man-rated sonic boom simulator capable of reproducing user-specified pressure signatures for a wide range of sonic boom parameters. One hundred and fifty sonic booms representing different combinations of two wave shapes, four rise times, seven durations, and three peak overpressures were presented to 36 test subjects in each experiment. The test subjects in the first experiment made judgments of 'loudness' while the test subjects in the second experiment judged 'annoyance.' Subjective response to sonic booms was the same whether expressed in terms of loudness or in terms of annoyance. Analyses of several different noise metrics indicated that A-weighted sound exposure level and Perceived Level were the best predictors of subjective response. Further analyses indicated that, of these two noise metrics, only Perceived Level completely accounted for the effects of wave shape, rise time, and peak overpressure. Neither metric fully accounted for the effect of duration. However, the magnitude of the duration effect was small over the very wide range of durations considered.
Two pilot studies of the effect of bicycling on balance and leg strength among older adults.
Rissel, Chris; Passmore, Erin; Mason, Chloe; Merom, Dafna
2013-01-01
Study 1 examines whether age-related declines in balance are moderated by bicycling. Study 2 tests whether regular cycling can increase leg strength and improve balance. Study 1: a cross-sectional survey of 43 adults aged 44-79 was conducted. Leg strength was measured, and Balance was measured using the choice stepping reaction time (CSRT) test (decision time and response time), leg strength and timed single leg standing. Study 2: 18 older adults aged 49-72 were recruited into a 12-week cycling program. The same pre- and postmeasures as used in Study 1 were collected. Study 1: participants who had cycled in the last month performed significantly better on measures of decision time and response time. Study 2: cycling at least one hour a week was associated with significant improvements in balance (decision time and response time) and timed single leg standing. Cycling by healthy older adults appears promising for improving risk factors for falls.
Two Pilot Studies of the Effect of Bicycling on Balance and Leg Strength among Older Adults
Rissel, Chris; Passmore, Erin; Mason, Chloe; Merom, Dafna
2013-01-01
Objectives. Study 1 examines whether age-related declines in balance are moderated by bicycling. Study 2 tests whether regular cycling can increase leg strength and improve balance. Methods. Study 1: a cross-sectional survey of 43 adults aged 44–79 was conducted. Leg strength was measured, and Balance was measured using the choice stepping reaction time (CSRT) test (decision time and response time), leg strength and timed single leg standing. Study 2: 18 older adults aged 49–72 were recruited into a 12-week cycling program. The same pre- and postmeasures as used in Study 1 were collected. Results. Study 1: participants who had cycled in the last month performed significantly better on measures of decision time and response time. Study 2: cycling at least one hour a week was associated with significant improvements in balance (decision time and response time) and timed single leg standing. Conclusions. Cycling by healthy older adults appears promising for improving risk factors for falls. PMID:23690805
Coiro, Vittorio; Volpi, Riccardo; Casti, Amos; Maffei, Maria Ludovica; Stella, Adriano; Volta, Elio; Chiodera, Paolo
2011-01-01
AIMS To establish the possible involvement of alprazolam (ALP) and/or opiates in the mechanism underlying the ACTH/cortisol response to physical exercise. METHODS Tests were carried out under basal conditions (exercise control test), exercise plus ALP (50 µg at time −90 min), naloxone (10 mg at time 0) or ALP plus naloxone. Plasma ACTH and serum cortisol concentrations were evaluated in blood samples taken before, during and after the bicycle ergometer tests. RESULTS ACTH and cortisol concentrations rose significantly after physical exercise. Maximum peak at time 15 min (P≤ 0.01 vs. baseline) for ACTH and at time 30 min (P≤ 0.01 vs. baseline) for cortisol. In the presence of naloxone, the ACTH and cortisol responses were significantly increased (maximum peak at time 20 min, P≤ 0.02 vs. control test for ACTH, and at time 30 min (P≤ 0.01 vs. baseline) for cortisol) whereas they were abolished by ALP. When ALP and naloxone were given together, the inhibitory effect of ALP was partial. CONCLUSIONS These data demonstrate an inhibitory effect of ALP in the regulation of the ACTH/cortisol response to physical exercise in man and suggest that GABAergic receptor activating benzodiazepines and opioids interact in the neuroendocrine secretion of ACTH/cortisol. PMID:21564163
Measuring older adults' sedentary time: reliability, validity, and responsiveness.
Gardiner, Paul A; Clark, Bronwyn K; Healy, Genevieve N; Eakin, Elizabeth G; Winkler, Elisabeth A H; Owen, Neville
2011-11-01
With evidence that prolonged sitting has deleterious health consequences, decreasing sedentary time is a potentially important preventive health target. High-quality measures, particularly for use with older adults, who are the most sedentary population group, are needed to evaluate the effect of sedentary behavior interventions. We examined the reliability, validity, and responsiveness to change of a self-report sedentary behavior questionnaire that assessed time spent in behaviors common among older adults: watching television, computer use, reading, socializing, transport and hobbies, and a summary measure (total sedentary time). In the context of a sedentary behavior intervention, nonworking older adults (n = 48, age = 73 ± 8 yr (mean ± SD)) completed the questionnaire on three occasions during a 2-wk period (7 d between administrations) and wore an accelerometer (ActiGraph model GT1M) for two periods of 6 d. Test-retest reliability (for the individual items and the summary measure) and validity (self-reported total sedentary time compared with accelerometer-derived sedentary time) were assessed during the 1-wk preintervention period, using Spearman (ρ) correlations and 95% confidence intervals (CI). Responsiveness to change after the intervention was assessed using the responsiveness statistic (RS). Test-retest reliability was excellent for television viewing time (ρ (95% CI) = 0.78 (0.63-0.89)), computer use (ρ (95% CI) = 0.90 (0.83-0.94)), and reading (ρ (95% CI) = 0.77 (0.62-0.86)); acceptable for hobbies (ρ (95% CI) = 0.61 (0.39-0.76)); and poor for socializing and transport (ρ < 0.45). Total sedentary time had acceptable test-retest reliability (ρ (95% CI) = 0.52 (0.27-0.70)) and validity (ρ (95% CI) = 0.30 (0.02-0.54)). Self-report total sedentary time was similarly responsive to change (RS = 0.47) as accelerometer-derived sedentary time (RS = 0.39). The summary measure of total sedentary time has good repeatability and modest validity and is sufficiently responsive to change suggesting that it is suitable for use in interventions with older adults.
Linnemann, Birgit; Prochnow, Stephanie; Mani, Helen; Schwonberg, Jan; Lindhoff-Last, Edelgard
2009-10-01
Non-responsiveness to aspirin as detected by laboratory tests may identify patients at high risk for future vascular events. The aim of this prospective study was to evaluate whether non-responsiveness to aspirin is stable over time. Ninety-eight patients with stable peripheral arterial occlusive disease (PAOD) treated with 100 mg/d aspirin were followed over a median timeframe of 17 months. Platelet function tests were performed initially and at follow-up using arachidonic acid-induced light transmittance aggregometry (LTA) in native platelet-rich plasma with the Behring Coagulation Timer and by measuring the collagen-epinephrine closure time (CT) on a Platelet Function Analyzer (PFA-100). When determining platelet function using LTA, four patients (4.1%) had residual platelet function (i.e., MaxAggr > or =78%) despite aspirin treatment, whereas, according to the PFA-100 results, 12 patients (12.2%) were identified as non-responders (i.e., CT <192 s). Fifty-seven patients who were still under treatment with 100 mg/d aspirin at the time of follow-up provided a second blood sample. Further platelet function tests with the PFA-100 system identified a persistent non-responsiveness to aspirin over time in three patients (5.3%) whereas four (7.0%) and 15 (26.3%) patients had changes in response status when platelet function was assessed by LTA and on the PFA-100(R), respectively. We conclude that true non-responsiveness to aspirin is a rare phenomenon in stable PAOD patients. Furthermore, we conclude that in a number of patients, aspirin non-responsiveness is not stable over time.
Fung, Helene H; Carstensen, Laura L
2004-03-01
Socioemotional selectivity theory contends that when people perceive time as limited, they prioritize emotionally meaningful goals. Although empirical support for the theory has been found in several studies, 2 alternative explanations for the pattern of findings remain: (a) emotional goals are pursued by default because nonemotional goals are blocked, and (b) emotional goals are pursued in search of emotional support rather than emotional meaning. This study tested these alternatives by examining social goals in response to blocked goals and foreshortened time. Findings reveal distinct motivational patterns, as reflected in social preferences and self-reported social goals, in response to the 2 types of constraints.
Derchi, Giacomo; Manca, Enrico; Shayganpour, Amirreza; Barone, Antonio; Diaspro, Alberto; Salerno, Marco
2015-01-01
We investigated the temporal response of four dental impression materials, namely three siloxanes (Imprint 4, Flexitime, Aquasil) and one polyether (Impregum). The null hypothesis was that the nominal working times are confirmed by instrumental laboratory tests. We also aimed to identify alternative techniques with strong physical-chemical background for the assessment of temporal response. Traditional characterization was carried out by shark fin test device and durometer at both ambient and body temperature. Additionally, Fourier-transform infrared spectroscopy was performed at room temperature. From shark fin height and Shore hardness versus time the working time and the setting time of the materials were evaluated, respectively. These were in reasonable agreement with the nominal values, except for Impregum, which showed longer working time. Spectroscopy confirmed the different character of the two types of materials, and provided for Imprint 4 and Aquasil an independent evaluation of both evolution times, consistent with the results of the other techniques. Shark fin test and durometer measurements showed deviations in setting time, low sensitivity to temperature for Flexitime, and longer working time at higher temperature for Impregum. Deviations of working time appear in operating conditions from what specified by the manufacturers. Fourier-transform infrared spectroscopy can provide insight in the correlation between material properties and their composition and structure.
Pitchford, Melanie; Ball, Linden J.; Hunt, Thomas E.; Steel, Richard
2017-01-01
We report a study examining the role of ‘cognitive miserliness’ as a determinant of poor performance on the standard three-item Cognitive Reflection Test (CRT). The cognitive miserliness hypothesis proposes that people often respond incorrectly on CRT items because of an unwillingness to go beyond default, heuristic processing and invest time and effort in analytic, reflective processing. Our analysis (N = 391) focused on people’s response times to CRT items to determine whether predicted associations are evident between miserly thinking and the generation of incorrect, intuitive answers. Evidence indicated only a weak correlation between CRT response times and accuracy. Item-level analyses also failed to demonstrate predicted response-time differences between correct analytic and incorrect intuitive answers for two of the three CRT items. We question whether participants who give incorrect intuitive answers on the CRT can legitimately be termed cognitive misers and whether the three CRT items measure the same general construct. PMID:29099840
Molenaar, Dylan; Bolsinova, Maria
2017-05-01
In generalized linear modelling of responses and response times, the observed response time variables are commonly transformed to make their distribution approximately normal. A normal distribution for the transformed response times is desirable as it justifies the linearity and homoscedasticity assumptions in the underlying linear model. Past research has, however, shown that the transformed response times are not always normal. Models have been developed to accommodate this violation. In the present study, we propose a modelling approach for responses and response times to test and model non-normality in the transformed response times. Most importantly, we distinguish between non-normality due to heteroscedastic residual variances, and non-normality due to a skewed speed factor. In a simulation study, we establish parameter recovery and the power to separate both effects. In addition, we apply the model to a real data set. © 2017 The Authors. British Journal of Mathematical and Statistical Psychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.
Lost time: Bindings do not represent temporal order information.
Moeller, Birte; Frings, Christian
2018-06-04
Many accounts of human action control assume bindings between features of stimuli and responses of individual events. One widely accepted assumption about these bindings is that they do not contain temporal-order representations regarding the integrated elements. Even though several theories either explicitly or implicitly include it, this assumption has never been tested directly. One reason for this lack of evidence is likely that typical stimulus-response binding paradigms are inapt for such a test. Adapting a new paradigm of response-response binding to include order switches between response integration and retrieval, we were able to analyze possible representation of order information in bindings for the first time. Binding effects were identical for intact and switched response orders, indicating that bindings indeed include no temporal-order information.
NASA Technical Reports Server (NTRS)
Proctor, Margaret P.; Gunter, Edgar J.
2005-01-01
Synchronous and nonsynchronous whirl response analysis of a double overhung, high-speed seal test rotor with ball bearings supported in 5.84- and 12.7-mm-long, un-centered squeeze-film oil dampers is presented. Test performance with the original damper of length 5.84 mm was marginal, with nonsynchronous whirling at the overhung seal test disk and high amplitude synchronous response above 32,000 rpm near the drive spline section occurring. A system critical speed analysis of the drive system and the high-speed seal test rotor indicated that the first two critical speeds are associated with the seal test rotor. Nonlinear synchronous unbalance and time transient whirl studies were conducted on the seal test rotor with the original and extended damper lengths. With the original damper design, the nonlinear synchronous response showed that unbalance could cause damper lockup at 33,000 rpm. Alford cross-coupling forces were also included at the overhung seal test disk for the whirl analysis. Sub-synchronous whirling at the seal test disk was observed in the nonlinear time transient analysis. With the extended damper length of 12.7 mm, the sub-synchronous motion was eliminated and the rotor unbalance response was acceptable to 45,000 rpm with moderate rotor unbalance. However, with high rotor unbalance, damper lockup could still occur at 33,000 rpm, even with the extended squeeze-film dampers. Therefore, the test rotor must be reasonably balanced in order for the un-centered dampers to be effective.
Clinical utility and validity of minoxidil response testing in androgenetic alopecia.
Goren, Andy; Shapiro, Jerry; Roberts, Janet; McCoy, John; Desai, Nisha; Zarrab, Zoulikha; Pietrzak, Aldona; Lotti, Torello
2015-01-01
Clinical response to 5% topical minoxidil for the treatment of androgenetic alopecia (AGA) is typically observed after 3-6 months. Approximately 40% of patients will regrow hair. Given the prolonged treatment time required to elicit a response, a diagnostic test for ruling out nonresponders would have significant clinical utility. Two studies have previously reported that sulfotransferase enzyme activity in plucked hair follicles predicts a patient's response to topical minoxidil therapy. The aim of this study was to assess the clinical utility and validity of minoxidil response testing. In this communication, the present authors conducted an analysis of completed and ongoing studies of minoxidil response testing. The analysis confirmed the clinical utility of a sulfotransferase enzyme test in successfully ruling out 95.9% of nonresponders to topical minoxidil for the treatment of AGA. © 2014 Wiley Periodicals, Inc.
LIMO EEG: a toolbox for hierarchical LInear MOdeling of ElectroEncephaloGraphic data.
Pernet, Cyril R; Chauveau, Nicolas; Gaspar, Carl; Rousselet, Guillaume A
2011-01-01
Magnetic- and electric-evoked brain responses have traditionally been analyzed by comparing the peaks or mean amplitudes of signals from selected channels and averaged across trials. More recently, tools have been developed to investigate single trial response variability (e.g., EEGLAB) and to test differences between averaged evoked responses over the entire scalp and time dimensions (e.g., SPM, Fieldtrip). LIMO EEG is a Matlab toolbox (EEGLAB compatible) to analyse evoked responses over all space and time dimensions, while accounting for single trial variability using a simple hierarchical linear modelling of the data. In addition, LIMO EEG provides robust parametric tests, therefore providing a new and complementary tool in the analysis of neural evoked responses.
LIMO EEG: A Toolbox for Hierarchical LInear MOdeling of ElectroEncephaloGraphic Data
Pernet, Cyril R.; Chauveau, Nicolas; Gaspar, Carl; Rousselet, Guillaume A.
2011-01-01
Magnetic- and electric-evoked brain responses have traditionally been analyzed by comparing the peaks or mean amplitudes of signals from selected channels and averaged across trials. More recently, tools have been developed to investigate single trial response variability (e.g., EEGLAB) and to test differences between averaged evoked responses over the entire scalp and time dimensions (e.g., SPM, Fieldtrip). LIMO EEG is a Matlab toolbox (EEGLAB compatible) to analyse evoked responses over all space and time dimensions, while accounting for single trial variability using a simple hierarchical linear modelling of the data. In addition, LIMO EEG provides robust parametric tests, therefore providing a new and complementary tool in the analysis of neural evoked responses. PMID:21403915
21 CFR 864.7275 - Euglobulin lysis time tests.
Code of Federal Regulations, 2012 CFR
2012-04-01
... time required for the lysis (dissolution) of a clot formed from fibrinogen in the euglobulin fraction (that fraction of the plasma responsible for the formation of plasmin, a clot lysing enzyme). This test evaluates natural fibrinolysis (destruction of a blood clot after bleeding has been arrested). The test also...
21 CFR 864.7275 - Euglobulin lysis time tests.
Code of Federal Regulations, 2013 CFR
2013-04-01
... time required for the lysis (dissolution) of a clot formed from fibrinogen in the euglobulin fraction (that fraction of the plasma responsible for the formation of plasmin, a clot lysing enzyme). This test evaluates natural fibrinolysis (destruction of a blood clot after bleeding has been arrested). The test also...
21 CFR 864.7275 - Euglobulin lysis time tests.
Code of Federal Regulations, 2011 CFR
2011-04-01
... time required for the lysis (dissolution) of a clot formed from fibrinogen in the euglobulin fraction (that fraction of the plasma responsible for the formation of plasmin, a clot lysing enzyme). This test evaluates natural fibrinolysis (destruction of a blood clot after bleeding has been arrested). The test also...
21 CFR 864.7275 - Euglobulin lysis time tests.
Code of Federal Regulations, 2014 CFR
2014-04-01
... time required for the lysis (dissolution) of a clot formed from fibrinogen in the euglobulin fraction (that fraction of the plasma responsible for the formation of plasmin, a clot lysing enzyme). This test evaluates natural fibrinolysis (destruction of a blood clot after bleeding has been arrested). The test also...
Kierkegaard, Marie; Petitclerc, Émilie; Hébert, Luc J; Mathieu, Jean; Gagnon, Cynthia
2018-02-28
To assess changes and responsiveness in outcome measures of mobility, balance, muscle strength and manual dexterity in adults with myotonic dystrophy type 1. A 9-year longitudinal study conducted with 113 patients. The responsiveness of the Timed Up and Go test, Berg Balance Scale, quantitative muscle testing, grip and pinch-grip strength, and Purdue Pegboard Test was assessed using criterion and construct approaches. Patient-reported perceived changes (worse/stable) in balance, walking, lower-limb weakness, stair-climbing and hand weakness were used as criteria. Predefined hypotheses about expected area under the receiver operating characteristic curves (criterion approach) and correlations between relative changes (construct approach) were explored. The direction and magnitude of median changes in outcome measures corresponded with patient-reported changes. Median changes in the Timed Up and Go test, grip strength, pinch-grip strength and Purdue Pegboard Test did not, in general, exceed known measurement errors. Most criterion (72%) and construct (70%) approach hypotheses were supported. Promising responsiveness was found for outcome measures of mobility, balance and muscle strength. Grip strength and manual dexterity measures showed poorer responsiveness. The performance-based outcome measures captured changes over the 9-year period and responsiveness was promising. Knowledge of measurement errors is needed to interpret the meaning of these longitudinal changes.
NASA Technical Reports Server (NTRS)
Allen, R. W.; Jex, H. R.
1972-01-01
In order to test various components of a regenerative life support system and to obtain data on the physiological and psychological effects of long-duration exposure to confinement in a space station atmosphere, four carefully screened young men were sealed in space station simulator for 90 days. A tracking test battery was administered during the above experiment. The battery included a clinical test (critical instability task) related to the subject's dynamic time delay, and a conventional steady tracking task, during which dynamic response (describing functions) and performance measures were obtained. Good correlation was noted between the clinical critical instability scores and more detailed tracking parameters such as dynamic time delay and gain-crossover frequency. The comprehensive data base on human operator tracking behavior obtained in this study demonstrate that sophisticated visual-motor response properties can be efficiently and reliably measured over extended periods of time.
Bojcic, Jamie L; Sue, Valerie M; Huon, Tomy S; Maletis, Gregory B; Inacio, Maria C S
2014-01-01
This study compared response rates of paper and electronic versions of the Knee injury Osteoarthritis and Outcome Score questionnaire and examined the characteristics of patients who responded to each survey method. A total of 1486 patients registered by the Kaiser Permanente Anterior Cruciate Ligament Reconstruction Registry between 2005 and 2010 were included in this study. Response rates by survey modality for the overall cohort, by the specific time periods, and by age and sex at time of anterior cruciate ligament reconstruction were compared using χ(2) tests or the Fisher exact test when appropriate. Independent Student t tests were used to compare the Knee injury Osteoarthritis and Outcome Scores of survey respondents. The overall survey response rate was 42%. The 36% response rate in the electronic-survey group was significantly higher than the 22% response rate in the paper-survey group (p < 0.001). The electronic response rate was also significantly higher than the paper response rate at all follow-up times (35% vs 25% at 1 year, p = 0.004, 38% vs 20% at 2 years, p < 0.001, and 35% vs 21% at 3 years; p < 0.001) and among all age groups 19 years and older. Although the electronic survey produced higher response rates, it is not sufficient alone to replace the traditional paper version among this Kaiser Permanente population.
Scanlan, Aaron; Humphries, Brendan; Tucker, Patrick S; Dalbo, Vincent
2014-01-01
This study explored the influence of physical and cognitive measures on reactive agility performance in basketball players. Twelve men basketball players performed multiple sprint, Change of Direction Speed Test, and Reactive Agility Test trials. Pearson's correlation analyses were used to determine relationships between the predictor variables (stature, mass, body composition, 5-m, 10-m and 20-m sprint times, peak speed, closed-skill agility time, response time and decision-making time) and reactive agility time (response variable). Simple and stepwise regression analyses determined the individual influence of each predictor variable and the best predictor model for reactive agility time. Morphological (r = -0.45 to 0.19), sprint (r = -0.40 to 0.41) and change-of-direction speed measures (r = 0.43) had small to moderate correlations with reactive agility time. Response time (r = 0.76, P = 0.004) and decision-making time (r = 0.58, P = 0.049) had large to very large relationships with reactive agility time. Response time was identified as the sole predictor variable for reactive agility time in the stepwise model (R(2) = 0.58, P = 0.004). In conclusion, cognitive measures had the greatest influence on reactive agility performance in men basketball players. These findings suggest reaction and decision-making drills should be incorporated in basketball training programmes.
Preference as a Function of Active Interresponse Times: A Test of the Active Time Model
ERIC Educational Resources Information Center
Misak, Paul; Cleaveland, J. Mark
2011-01-01
In this article, we describe a test of the active time model for concurrent variable interval (VI) choice. The active time model (ATM) suggests that the time since the most recent response is one of the variables controlling choice in concurrent VI VI schedules of reinforcement. In our experiment, pigeons were trained in a multiple concurrent…
NASA Technical Reports Server (NTRS)
Bragg-Sitton, Shannon M.; Hervol, David S.; Godfroy, Thomas J.
2009-01-01
A Direct Drive Gas-Cooled (DDG) reactor core simulator has been coupled to a Brayton Power Conversion Unit (BPCU) for integrated system testing at NASA Glenn Research Center (GRC) in Cleveland, OH. This is a closed-cycle system that incorporates an electrically heated reactor core module, turbo alternator, recuperator, and gas cooler. Nuclear fuel elements in the gas-cooled reactor design are replaced with electric resistance heaters to simulate the heat from nuclear fuel in the corresponding fast spectrum nuclear reactor. The thermodynamic transient behavior of the integrated system was the focus of this test series. In order to better mimic the integrated response of the nuclear-fueled system, a simulated reactivity feedback control loop was implemented. Core power was controlled by a point kinetics model in which the reactivity feedback was based on core temperature measurements; the neutron generation time and the temperature feedback coefficient are provided as model inputs. These dynamic system response tests demonstrate the overall capability of a non-nuclear test facility in assessing system integration issues and characterizing integrated system response times and response characteristics.
NASA Technical Reports Server (NTRS)
Bragg-Sitton, Shannon M.; Hervol, David S.; Godfroy, Thomas J.
2010-01-01
A Direct Drive Gas-Cooled (DDG) reactor core simulator has been coupled to a Brayton Power Conversion Unit (BPCU) for integrated system testing at NASA Glenn Research Center (GRC) in Cleveland, Ohio. This is a closed-cycle system that incorporates an electrically heated reactor core module, turboalternator, recuperator, and gas cooler. Nuclear fuel elements in the gas-cooled reactor design are replaced with electric resistance heaters to simulate the heat from nuclear fuel in the corresponding fast spectrum nuclear reactor. The thermodynamic transient behavior of the integrated system was the focus of this test series. In order to better mimic the integrated response of the nuclear-fueled system, a simulated reactivity feedback control loop was implemented. Core power was controlled by a point kinetics model in which the reactivity feedback was based on core temperature measurements; the neutron generation time and the temperature feedback coefficient are provided as model inputs. These dynamic system response tests demonstrate the overall capability of a non-nuclear test facility in assessing system integration issues and characterizing integrated system response times and response characteristics.
Fried, Itzhak; Koch, Christof
2014-01-01
Peristimulus time histograms are a widespread form of visualizing neuronal responses. Kernel convolution methods transform these histograms into a smooth, continuous probability density function. This provides an improved estimate of a neuron's actual response envelope. We here develop a classifier, called the h-coefficient, to determine whether time-locked fluctuations in the firing rate of a neuron should be classified as a response or as random noise. Unlike previous approaches, the h-coefficient takes advantage of the more precise response envelope estimation provided by the kernel convolution method. The h-coefficient quantizes the smoothed response envelope and calculates the probability of a response of a given shape to occur by chance. We tested the efficacy of the h-coefficient in a large data set of Monte Carlo simulated smoothed peristimulus time histograms with varying response amplitudes, response durations, trial numbers, and baseline firing rates. Across all these conditions, the h-coefficient significantly outperformed more classical classifiers, with a mean false alarm rate of 0.004 and a mean hit rate of 0.494. We also tested the h-coefficient's performance in a set of neuronal responses recorded in humans. The algorithm behind the h-coefficient provides various opportunities for further adaptation and the flexibility to target specific parameters in a given data set. Our findings confirm that the h-coefficient can provide a conservative and powerful tool for the analysis of peristimulus time histograms with great potential for future development. PMID:25475352
Li, Yi; Chen, Yuren
2016-12-30
To make driving assistance system more humanized, this study focused on the prediction and assistance of drivers' perception-response time on mountain highway curves. Field tests were conducted to collect real-time driving data and driver vision information. A driver-vision lane model quantified curve elements in drivers' vision. A multinomial log-linear model was established to predict perception-response time with traffic/road environment information, driver-vision lane model, and mechanical status (last second). A corresponding assistance model showed a positive impact on drivers' perception-response times on mountain highway curves. Model results revealed that the driver-vision lane model and visual elements did have important influence on drivers' perception-response time. Compared with roadside passive road safety infrastructure, proper visual geometry design, timely visual guidance, and visual information integrality of a curve are significant factors for drivers' perception-response time.
Passos, Luiza Figueiredo; Garcia, Gerardo; Young, Robert John
2017-01-01
Adaptations to captivity that reduce fitness are one of many reasons, which explain the low success rate of reintroductions. One way of testing this hypothesis is to compare an important behavioural response in captive and wild members of the same species. Thanatosis, is an anti-predator strategy that reduces the risk of death from predation, which is a common behavioral response in frogs. The study subjects for this investigation were captive and wild populations of Mantella aurantiaca. Thanatosis reaction was measured using the Tonic Immobility (TI) test, a method that consists of placing a frog on its back, restraining it in this position for a short period of time and then releasing it and measuring how much time was spent feigning death. To understand the pattern of reaction time, morphometric data were also collected as body condition can affect the duration of thanatosis. The significantly different TI times found in this study, one captive population with shorter responses, were principally an effect of body condition rather than being a result of rearing environment. However, this does not mean that we can always dismiss the importance of rearing environment in terms of behavioural skills expressed.
ERIC Educational Resources Information Center
Patching, Geoffrey R.; Englund, Mats P.; Hellstrom, Ake
2012-01-01
Despite the importance of both response probability and response time for testing models of choice, there is a dearth of chronometric studies examining systematic asymmetries that occur over time- and space-orders in the method of paired comparisons. In this study, systematic asymmetries in discriminating the magnitude of paired visual stimuli are…
NASA Technical Reports Server (NTRS)
Mantus, M.; Pardo, H.
1973-01-01
Computer programming, data processing, and a correlation study that employed data collected in the first phase test were used to demonstrate that standard test procedures and equipment could be used to collect a significant number of transfer functions from tests of the Lunar Module test article LTA-11. The testing consisted of suspending the vehicle from the apex fittings of the outrigger trusses through a set of air springs to simulate the free-free state. Impulsive loadings were delivered, one at a time, at each of the landing gear's attachment points, in three mutually perpendicular directions; thus a total of 36 impulses were applied to the vehicle. Time histories of each pulse were recorded on magnetic tape along with 40 channels of strain gage response and 28 channels of accelerometer response. Since an automated data processing system was not available, oscillograph playbacks were made of all 2400 time histories as a check on the validity of the data taken. In addition, one channel of instrumentation was processed to determine its response to a set of forcing functions from a prior LTA-11 drop test. This prediction was compared with drop test results as a first measure of accuracy.
Modeling and design of challenge tests: Inflammatory and metabolic biomarker study examples.
Gabrielsson, Johan; Hjorth, Stephan; Vogg, Barbara; Harlfinger, Stephanie; Gutierrez, Pablo Morentin; Peletier, Lambertus; Pehrson, Rikard; Davidsson, Pia
2015-01-25
Given the complexity of pharmacological challenge experiments, it is perhaps not surprising that design and analysis, and in turn interpretation and communication of results from a quantitative point of view, is often suboptimal. Here we report an inventory of common designs sampled from anti-inflammatory, respiratory and metabolic disease drug discovery studies, all of which are based on animal models of disease involving pharmacological and/or patho/physiological interaction challenges. The corresponding data are modeled and analyzed quantitatively, the merits of the respective approach discussed and inferences made with respect to future design improvements. Although our analysis is limited to these disease model examples, the challenge approach is generally applicable to the vast majority of pharmacological intervention studies. In the present five Case Studies results from pharmacodynamic effect models from different therapeutic areas were explored and analyzed according to five typical designs. Plasma exposures of test compounds were assayed by either liquid chromatography/mass spectrometry or ligand binding assays. To describe how drug intervention can regulate diverse processes, turnover models of test compound-challenger interaction, transduction processes, and biophase time courses were applied for biomarker response in eosinophil count, IL6 response, paw-swelling, TNFα response and glucose turnover in vivo. Case Study 1 shows results from intratracheal administration of Sephadex, which is a glucocorticoid-sensitive model of airway inflammation in rats. Eosinophils in bronchoalveolar fluid were obtained at different time points via destructive sampling and then regressed by the mixed-effects modeling. A biophase function of the Sephadex time course was inferred from the modeled eosinophil time courses. In Case Study 2, a mouse model showed that the time course of cytokine-induced IL1β challenge was altered with or without drug intervention. Anakinra reversed the IL1β induced cytokine IL6 response in a dose-dependent manner. This Case Study contained time courses of test compound (drug), challenger (IL1β) and cytokine response (IL6), which resulted in high parameter precision. Case Study 3 illustrates collagen-induced arthritis progression in the rat. Swelling scores (based on severity of hind paw swelling) were used to describe arthritis progression after the challenge and the inhibitory effect of two doses of an orally administered test compound. In Case Study 4, a cynomolgus monkey model for lipopolysaccharide LPS-induced TNFα synthesis and/or release was investigated. This model provides integrated information on pharmacokinetics and in vivo potency of the test compounds. Case Study 5 contains data from an oral glucose tolerance test in rats, where the challenger is the same as the pharmacodynamic response biomarker (glucose). It is therefore convenient to model the extra input of glucose simultaneously with baseline data and during intervention of a glucose-lowering compound at different dose levels. Typically time-series analyses of challenger- and biomarker-time data are necessary if an accurate and precise estimate of the pharmacodynamic properties of a test compound is sought. Erosion of data, resulting in the single-point assessment of drug action after a challenge test, should generally be avoided. This is particularly relevant for situations where one expects time-curve shifts, tolerance/rebound, impact of disease, or hormetic concentration-response relationships to occur. Copyright © 2014 Elsevier B.V. All rights reserved.
40 CFR 1066.245 - Response time verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... automated process to verify response time. You may perform this test either at two different inertia... base inertia and two acceleration rates that cover the range of acceleration rates experienced during... less than 100 milliseconds for each inertia setting. ER28AP14.066 ...
Nishi, Toshiko; Kamogashira, Teru; Fujimoto, Chisato; Kinoshita, Makoto; Egami, Naoya; Sugasawa, Keiko; Yamasoba, Tatsuya; Iwasaki, Shinichi
2017-06-01
To investigate the influence of vestibular function on dynamic postural stability assessed by the functional reach test (FRT) and the timed up and go test (TUG). Retrospective study. Tertiary referral center. The FRT and TUG were performed in 399 patients with dizziness. The effects of peripheral vestibular dysfunction assessed by the caloric test and cervical vestibular evoked myogenic potentials (cVEMPs) to air-conducted sound (500 Hz, tone burst) on the results of FRT and TUG were analyzed. Neither FRT nor TUG scores showed significant differences in relation to the results of the caloric test ( P > .3). The FRT scores in patients who showed abnormal cVEMP responses on both sides were significantly smaller than those in patients who showed normal cVEMP responses ( P < .01). The TUG scores in patients who showed abnormal cVEMP responses on both sides were significantly greater than those in patients who showed normal cVEMP responses ( P < .05). The vestibulo-spinal reflex mediated by the saccule and its afferents is one of the factors that influence the maintenance of dynamic postural stability as measured by FRT and TUG.
El-Gohary, Mahmoud; Peterson, Daniel; Gera, Geetanjali; Horak, Fay B; Huisinga, Jessie M
2017-07-01
To test the validity of wearable inertial sensors to provide objective measures of postural stepping responses to the push and release clinical test in people with multiple sclerosis. Cross-sectional study. University medical center balance disorder laboratory. Total sample N=73; persons with multiple sclerosis (PwMS) n=52; healthy controls n=21. Stepping latency, time and number of steps required to reach stability, and initial step length were calculated using 3 inertial measurement units placed on participants' lumbar spine and feet. Correlations between inertial sensor measures and measures obtained from the laboratory-based systems were moderate to strong and statistically significant for all variables: time to release (r=.992), latency (r=.655), time to stability (r=.847), time of first heel strike (r=.665), number of steps (r=.825), and first step length (r=.592). Compared with healthy controls, PwMS demonstrated a longer time to stability and required a larger number of steps to reach stability. The instrumented push and release test is a valid measure of postural responses in PwMS and could be used as a clinical outcome measures for patient care decisions or for clinical trials aimed at improving postural control in PwMS. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Commercial Building Motor Protection Response Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
James, Daniel P.; Kueck, John
2015-06-17
When voltages recover, motors may immediately reenergize and reaccelerate, or delay for a few minutes, or stay stalled. The estimated motor response is given for both the voltage sag magnitude and voltage sag duration. These response estimates are based on experience and available test data. Good data is available for voltage sag response for many components such as relays and contactors, but little data is available for both voltage sag and recovery response. The tables in Appendix A include data from recent voltage sag and recovery tests performed by SCE and BPA on air conditioners and energy management systems. Themore » response of the motor can vary greatly depending on the type of protection and control. The time duration for the voltage sag consists of those times that are of interest for bulk power system modelers.« less
Modal identification of structures from the responses and random decrement signatures
NASA Technical Reports Server (NTRS)
Brahim, S. R.; Goglia, G. L.
1977-01-01
The theory and application of a method which utilizes the free response of a structure to determine its vibration parameters is described. The time-domain free response is digitized and used in a digital computer program to determine the number of modes excited, the natural frequencies, the damping factors, and the modal vectors. The technique is applied to a complex generalized payload model previously tested using sine sweep method and analyzed by NASTRAN. Ten modes of the payload model are identified. In case free decay response is not readily available, an algorithm is developed to obtain the free responses of a structure from its random responses, due to some unknown or known random input or inputs, using the random decrement technique without changing time correlation between signals. The algorithm is tested using random responses from a generalized payload model and from the space shuttle model.
NASA Technical Reports Server (NTRS)
Delp, P.; Crossman, E. R. F. W.; Szostak, H.
1972-01-01
The automobile-driver describing function for lateral position control was estimated for three subjects from frequency response analysis of straight road test results. The measurement procedure employed an instrumented full size sedan with known steering response characteristics, and equipped with a lateral lane position measuring device based on video detection of white stripe lane markings. Forcing functions were inserted through a servo driven double steering wheel coupling the driver to the steering system proper. Random appearing, Gaussian, and transient time functions were used. The quasi-linear models fitted to the random appearing input frequency response characterized the driver as compensating for lateral position error in a proportional, derivative, and integral manner. Similar parameters were fitted to the Gabor transformed frequency response of the driver to transient functions. A fourth term corresponding to response to lateral acceleration was determined by matching the time response histories of the model to the experimental results. The time histories show evidence of pulse-like nonlinear behavior during extended response to step transients which appear as high frequency remnant power.
Real-time open-loop frequency response analysis of flight test data
NASA Technical Reports Server (NTRS)
Bosworth, J. T.; West, J. C.
1986-01-01
A technique has been developed to compare the open-loop frequency response of a flight test aircraft real time with linear analysis predictions. The result is direct feedback to the flight control systems engineer on the validity of predictions and adds confidence for proceeding with envelope expansion. Further, gain and phase margins can be tracked for trends in a manner similar to the techniques used by structural dynamics engineers in tracking structural modal damping.
Fitts' Law? a Test of the Relationship Between Information Load and Movement Precision
NASA Technical Reports Server (NTRS)
Zalaski, M.; Sanderson, P.
1984-01-01
The independence of information load (Hick's Law) and movement precision (Fitts' Law) was tested using additive factors methodology. Subjects were required to classify stimuli according to a decision rule with a variable entropy. The stimuli were presented in the center of the CRT screen. In response, subjects had to move a cursor from a starting point near the stimulus to the appropriate target. The precision of the response movement was varied by manipulating the ratio of the radius of the annulus to the width of the target area. The dependent measure was elapsed time between onset of the stimulus and completion of the response movement. Independence of the Hick's Law and Fitts' Law components of the reaction time was tested with an analysis of variance. Presence of an interaction would suggest that a decision stage and a response stage are dependent, and cannot be considered discrete steps in a serial process.
Conceptual question response times in Peer Instruction classrooms
NASA Astrophysics Data System (ADS)
Miller, Kelly; Lasry, Nathaniel; Lukoff, Brian; Schell, Julie; Mazur, Eric
2014-12-01
Classroom response systems are widely used in interactive teaching environments as a way to engage students by asking them questions. Previous research on the time taken by students to respond to conceptual questions has yielded insights on how students think and change conceptions. We measure the amount of time students take to respond to in-class, conceptual questions [ConcepTests (CTs)] in two introductory physics courses taught using Peer Instruction and use item response theory to determine the difficulty of the CTs. We examine response time differences between correct and incorrect answers both before and after the peer discussion for CTs of varying difficulty. We also determine the relationship between response time and student performance on a standardized test of incoming physics knowledge, precourse self-efficacy, and gender. Our data reveal three results of interest. First, response time for correct answers is significantly faster than for incorrect answers, both before and after peer discussion, especially for easy CTs. Second, students with greater incoming physics knowledge and higher self-efficacy respond faster in both rounds. Third, there is no gender difference in response rate after controlling for incoming physics knowledge scores, although males register significantly more attempts before committing to a final answer than do female students. These results provide insight into effective CT pacing during Peer Instruction. In particular, in order to maintain a pace that keeps everyone engaged, students should not be given too much time to respond. When around 80% of the answers are in, the ratio of correct to incorrect responses rapidly approaches levels indicating random guessing and instructors should close the poll.
Flores-Serrano, Ana G; Zaldívar-Rae, Jaime; Salgado, Humberto; Pineda, Juan C
2015-03-25
Among the main issues in the pharmacological treatment of depression are the wide variation in response to antidepressants among individual patients and the lack of indexes that allow prediction of which drug will be effective in a particular case. We evaluated whether differential sensitivity to amitriptyline is related to dichotomous categorization of individuals on the basis of their behavioral responses to two common paradigms used to evaluate the potential of tricyclic drugs as antidepressants. Hence, we categorized a cohort of 38 female rats on the basis of their immobility time in the conditioning phase of the forced swimming test [FST; high immobility (HI) vs. low immobility (LI) rats] and their locomotor behavior in the circular corridor test [high locomotor response (HR) vs. low locomotor response (LR) rats]. We subjected the rodents to the FST while under the influence of vehicle (n=20) or amitriptyline (15 mg/kg; n=18). We found no statistical evidence of dependence between categorizations of rats on the basis of their behavior in the FST and circular corridor test. Rats categorized as HI/LI and HR/LR significantly differed in their sensitivity/resistance to amitriptyline, as evidenced by changes (or lack thereof) in their immobility time, climbing time, and swimming time during the FST. These results confirm that different behavioral styles among rats are linked to differential sensitivity/resistance to antidepressants. However, we specifically found that categorizing rats as HI/LI better reflected sensitivity to amitriptyline, whereas categorizing them as HR/LR better revealed resistance to the drug. These differential responses should be considered in experimental approaches. Copyright © 2015 Wolters Kluwer Health, Inc. All rights reserved.
On-Line, Self-Learning, Predictive Tool for Determining Payload Thermal Response
NASA Technical Reports Server (NTRS)
Jen, Chian-Li; Tilwick, Leon
2000-01-01
This paper will present the results of a joint ManTech / Goddard R&D effort, currently under way, to develop and test a computer based, on-line, predictive simulation model for use by facility operators to predict the thermal response of a payload during thermal vacuum testing. Thermal response was identified as an area that could benefit from the algorithms developed by Dr. Jeri for complex computer simulations. Most thermal vacuum test setups are unique since no two payloads have the same thermal properties. This requires that the operators depend on their past experiences to conduct the test which requires time for them to learn how the payload responds while at the same time limiting any risk of exceeding hot or cold temperature limits. The predictive tool being developed is intended to be used with the new Thermal Vacuum Data System (TVDS) developed at Goddard for the Thermal Vacuum Test Operations group. This model can learn the thermal response of the payload by reading a few data points from the TVDS, accepting the payload's current temperature as the initial condition for prediction. The model can then be used as a predictive tool to estimate the future payload temperatures according to a predetermined shroud temperature profile. If the error of prediction is too big, the model can be asked to re-learn the new situation on-line in real-time and give a new prediction. Based on some preliminary tests, we feel this predictive model can forecast the payload temperature of the entire test cycle within 5 degrees Celsius after it has learned 3 times during the beginning of the test. The tool will allow the operator to play "what-if' experiments to decide what is his best shroud temperature set-point control strategy. This tool will save money by minimizing guess work and optimizing transitions as well as making the testing process safer and easier to conduct.
Miller, M R; Atkins, P R; Pedersen, O F
2003-05-01
Recent evidence suggests that the frequency response requirements for peak expiratory flow (PEF) meters are higher than was first thought and that the American Thoracic Society (ATS) waveforms to test PEF meters may not be adequate for the purpose. The dynamic response of mini-Wright (MW), Vitalograph (V), TruZone (TZ), MultiSpiro (MS) and pneumotachograph (PT) flow meters was tested by delivering two differently shaped flow-time profiles from a computer controlled explosive decompression device fitted with a fast response solenoid valve. These profiles matched population 5th and 95th centiles for rise time from 10% to 90% of PEF and dwell time of flow above 90% PEF. Profiles were delivered five times with identical chamber pressure and solenoid aperture at PEF. Any difference in recorded PEF for the two profiles indicates a poor dynamic response. The absolute (% of mean) flow differences in l/min for the V, MW, and PT PEF meters were 25 (4.7), 20 (3.9), and 2 (0.3), respectively, at PEF approximately 500 l/min, and 25 (10.5), 20 (8.7) and 6 (3.0) at approximately 200 l/min. For TZ and MS meters at approximately 500 l/min the differences were 228 (36.1) and 257 (39.2), respectively, and at approximately 200 l/min they were 51 (23.9) and 1 (0.5). All the meters met ATS accuracy requirements when tested with their waveforms. An improved method for testing the dynamic response of flow meters detects marked overshoot (underdamping) of TZ and MS responses not identified by the 26 ATS waveforms. This error could cause patient misclassification when using such meters with asthma guidelines.
NASA Technical Reports Server (NTRS)
Reda, Daniel C.; Muratore, Joseph J., Jr.; Heineck, James T.
1993-01-01
Time and flow-direction responses of shearstress-sensitive liquid crystal coatings were explored experimentally. For the time-response experiments, coatings were exposed to transient, compressible flows created during the startup and off-design operation of an injector-driven supersonic wind tunnel. Flow transients were visualized with a focusing Schlieren system and recorded with a 1000 frame/sec color video camera. Liquid crystal responses to these changing-shear environments were then recorded with the same video system, documenting color-play response times equal to, or faster than, the time interval between sequential frames (i.e., 1 millisecond). For the flow-direction experiments, a planar test surface was exposed to equal-magnitude and known-direction surface shear stresses generated by both normal and tangential subsonic jet-impingement flows. Under shear, the sense of the angular displacement of the liquid crystal dispersed (reflected) spectrum was found to be a function of the instantaneous direction of the applied shear. This technique thus renders dynamic flow reversals or flow divergences visible over entire test surfaces at image recording rates up to 1 KHz. Extensions of the technique to visualize relatively small changes in surface shear stress direction appear feasible.
Molenaar, Dylan; de Boeck, Paul
2018-06-01
In item response theory modeling of responses and response times, it is commonly assumed that the item responses have the same characteristics across the response times. However, heterogeneity might arise in the data if subjects resort to different response processes when solving the test items. These differences may be within-subject effects, that is, a subject might use a certain process on some of the items and a different process with different item characteristics on the other items. If the probability of using one process over the other process depends on the subject's response time, within-subject heterogeneity of the item characteristics across the response times arises. In this paper, the method of response mixture modeling is presented to account for such heterogeneity. Contrary to traditional mixture modeling where the full response vectors are classified, response mixture modeling involves classification of the individual elements in the response vector. In a simulation study, the response mixture model is shown to be viable in terms of parameter recovery. In addition, the response mixture model is applied to a real dataset to illustrate its use in investigating within-subject heterogeneity in the item characteristics across response times.
Reversing the picture superiority effect: a speed-accuracy trade-off study of recognition memory.
Boldini, Angela; Russo, Riccardo; Punia, Sahiba; Avons, S E
2007-01-01
Speed-accuracy trade-off methods have been used to contrast single- and dual-process accounts of recognition memory. With these procedures, subjects are presented with individual test items and required to make recognition decisions under various time constraints. In three experiments, we presented words and pictures to be intentionally learned; test stimuli were always visually presented words. At test, we manipulated the interval between the presentation of each test stimulus and that of a response signal, thus controlling the amount of time available to retrieve target information. The standard picture superiority effect was significant in long response deadline conditions (i.e., > or = 2,000 msec). Conversely, a significant reverse picture superiority effect emerged at short response-signal deadlines (< 200 msec). The results are congruent with views suggesting that both fast familiarity and slower recollection processes contribute to recognition memory. Alternative accounts are also discussed.
One process is not enough! A speed-accuracy tradeoff study of recognition memory.
Boldini, Angela; Russo, Riccardo; Avons, S E
2004-04-01
Speed-accuracy tradeoff (SAT) methods have been used to contrast single- and dual-process accounts of recognition memory. In these procedures, subjects are presented with individual test items and are required to make recognition decisions under various time constraints. In this experiment, we presented word lists under incidental learning conditions, varying the modality of presentation and level of processing. At test, we manipulated the interval between each visually presented test item and a response signal, thus controlling the amount of time available to retrieve target information. Study-test modality match had a beneficial effect on recognition accuracy at short response-signal delays (< or =300 msec). Conversely, recognition accuracy benefited more from deep than from shallow processing at study only at relatively long response-signal delays (> or =300 msec). The results are congruent with views suggesting that both fast familiarity and slower recollection processes contribute to recognition memory.
Voltage controlled current source
Casne, Gregory M.
1992-01-01
A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.
Donovan, Oliver O; Cheung, Jeanette; Catley, Maria; McGregor, Alison H; Strutton, Paul H
2006-01-01
The purpose of this study was to investigate trunk and knee strength in practitioners of hard-style martial arts. An additional objective was to examine reaction times in these participants by measuring simple reaction times (SRT), choice reaction times (CRT) and movement times (MT). Thirteen high-level martial artists and twelve sedentary participants were tested under isokinetic and isometric conditions on an isokinetic dynamometer. Response and movement times were also measured in response to simple and choice auditory cues. Results indicated that the martial arts group generated a greater body-weight adjusted peak torque with both legs at all speeds during isokinetic extension and flexion, and in isometric extension but not flexion. In isokinetic and isometric trunk flexion and extension, martial artists tended to have higher peak torques than controls, but they were not significantly different (p > 0.05). During the SRT and CRT tasks the martial artists were no quicker in lifting their hand off a button in response to the stimulus [reaction time (RT)] but were significantly faster in moving to press another button [movement time (MT)]. In conclusion, the results reveal that training in a martial art increases the strength of both the flexors and extensors of the leg. Furthermore, they have faster movement times to auditory stimuli. These results are consistent with the physical aspects of the martial arts. Key PointsMartial artists undertaking hard-style martial arts have greater strength in their knee flexor and extensor muscles as tested under isokinetic testing. Under isometric testing conditions they have stronger knee extensors only.The trunk musculature is generally higher under both conditions of testing in the martial artists, although not significantly.The total reaction times of the martial artists to an auditory stimulus were significantly faster than the control participants. When analysed further it was revealed that the decrease in reaction time was due to the movement time component of the total reaction time.The training involved for the practice of the hard-style martial arts increases the strength of muscles involved in kicking. This increased strength is not seen in the trunk muscles. Furthermore, martial artists have a faster response time; the cause of which appears to be only the faster movement time.
Donovan, Oliver O; Cheung, Jeanette; Catley, Maria; McGregor, Alison H.; Strutton, Paul H.
2006-01-01
The purpose of this study was to investigate trunk and knee strength in practitioners of hard-style martial arts. An additional objective was to examine reaction times in these participants by measuring simple reaction times (SRT), choice reaction times (CRT) and movement times (MT). Thirteen high-level martial artists and twelve sedentary participants were tested under isokinetic and isometric conditions on an isokinetic dynamometer. Response and movement times were also measured in response to simple and choice auditory cues. Results indicated that the martial arts group generated a greater body-weight adjusted peak torque with both legs at all speeds during isokinetic extension and flexion, and in isometric extension but not flexion. In isokinetic and isometric trunk flexion and extension, martial artists tended to have higher peak torques than controls, but they were not significantly different (p > 0.05). During the SRT and CRT tasks the martial artists were no quicker in lifting their hand off a button in response to the stimulus [reaction time (RT)] but were significantly faster in moving to press another button [movement time (MT)]. In conclusion, the results reveal that training in a martial art increases the strength of both the flexors and extensors of the leg. Furthermore, they have faster movement times to auditory stimuli. These results are consistent with the physical aspects of the martial arts. Key Points Martial artists undertaking hard-style martial arts have greater strength in their knee flexor and extensor muscles as tested under isokinetic testing. Under isometric testing conditions they have stronger knee extensors only. The trunk musculature is generally higher under both conditions of testing in the martial artists, although not significantly. The total reaction times of the martial artists to an auditory stimulus were significantly faster than the control participants. When analysed further it was revealed that the decrease in reaction time was due to the movement time component of the total reaction time. The training involved for the practice of the hard-style martial arts increases the strength of muscles involved in kicking. This increased strength is not seen in the trunk muscles. Furthermore, martial artists have a faster response time; the cause of which appears to be only the faster movement time. PMID:24376366
Code of Federal Regulations, 2014 CFR
2014-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2010 CFR
2010-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2013 CFR
2013-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Code of Federal Regulations, 2011 CFR
2011-07-01
....2Response Time Test. Conduct this test once prior to each test series. Introduce zero gas into the... analysis. 3.0Definitions 3.1Capture efficiency (CE). The weight per unit time of SF6 entering the control device divided by the weight per unit time of SF6 released through manifolds at multiple locations within...
Testing of the anemometer circuit: Data report
NASA Technical Reports Server (NTRS)
Moen, Michael J.
1992-01-01
The following text discusses results from the electronic step testing and the beginning of velocity step testing in the shock tube. It should be kept in mind that frequency response is always measured as the time from the beginning of the event to the minimum (positive inflection) of the 'bucket' that immediately follows the response. This report is not a complete account of the results from square wave testing. Some data is still in the process of being analyzed and efforts are being made to fit the data to both Freymuth's third order theory and modelled responses from SPICE circuit simulation software.
NASA Technical Reports Server (NTRS)
Brown, A. H.; Chapman, D. K.; Johnsson, A.; Heathcote, D.
1995-01-01
We conducted a series of gravitropic experiments on Avena coleoptiles in the weightlessness environment of Spacelab. The purpose was to test the threshold stimulus, reciprocity rule and autotropic reactions to a range of g-force stimulations of different intensities and durations The tests avoided the potentially complicating effects of earth's gravity and the interference from clinostat ambiguities. Using slow-speed centrifuges, coleoptiles received transversal accelerations in the hypogravity range between 0.l and 1.0 g over periods that ranged from 2 to 130 min. All responses that occurred in weightlessness were compared to clinostat experiments on earth using the same apparatus. Characteristic gravitropistic response patterns of Atuena were not substantially different from those observed in ground-based experiments. Gravitropic presentation times were extrapolated. The threshold at 1.0 g was less than 1 min (shortest stimulation time 2 min), in agreement with values obtained on the ground. The least stimulus tested, 0.1 g for 130 min, produced a significant response. Therefore the absolute threshold for a gravitropic response is less than 0.1 g.
Pollet-Villard, Marie; Cartier, Régine; Gaucherand, Pascal; Doret, Muriel
2011-06-01
We compared two biochemical tests of premature rupture of membranes (PROM) in vitro: Actim PROM (Medix Biochemica, Kauniainen, Finland), which detects insulin-like growth factor binding protein-1, and AmniSure (AmniSure International LLC, Cambridge, MA), which detects placental alpha microglobulin-1. Samples of amniotic fluid were collected during caesarean section in 41 patients. A dilution series was prepared and both tests were performed twice at each dilution. Sensitivity, detection limit, response time, and reproducibility of both tests were compared. Both tests' sensitivity was 100% at dilution 1:10 and 1:20. AmniSure sensitivity was higher at dilution 1:40 and 1:80 ( P < 0.05). In 29 of 40 cases, AmniSure had a lower detection limit than Actim PROM. AmniSure response times were shorter and reproducibility was higher than Actim PROM ( P < 0.05). AmniSure had a lower detection limit of amniotic fluid than Actim PROM, with a shorter response time, a higher sensitivity, and a better reproducibility. © Thieme Medical Publishers.
NASA Astrophysics Data System (ADS)
Lenferna, Georges Alexandre; Russotto, Rick D.; Tan, Amanda; Gardiner, Stephen M.; Ackerman, Thomas P.
2017-06-01
In this paper, we focus on stratospheric sulfate injection as a geoengineering scheme, and provide a combined scientific and ethical analysis of climate response tests, which are a subset of outdoor tests that would seek to impose detectable and attributable changes to climate variables on global or regional scales. We assess the current state of scientific understanding on the plausibility and scalability of climate response tests. Then, we delineate a minimal baseline against which to consider whether certain climate response tests would be relevant for a deployment scenario. Our analysis shows that some climate response tests, such as those attempting to detect changes in regional climate impacts, may not be deployable in time periods relevant to realistic geoengineering scenarios. This might pose significant challenges for justifying stratospheric sulfate aerosol injection deployment overall. We then survey some of the major ethical challenges that proposed climate response tests face. We consider what levels of confidence would be required to ethically justify approving a proposed test; whether the consequences of tests are subject to similar questions of justice, compensation, and informed consent as full-scale deployment; and whether questions of intent and hubris are morally relevant for climate response tests. We suggest further research into laboratory-based work and modeling may help to narrow the scientific uncertainties related to climate response tests, and help inform future ethical debate. However, even if such work is pursued, the ethical issues raised by proposed climate response tests are significant and manifold.
Type testing of the Siemens Plessey electronic personal dosemeter.
Hirning, C R; Yuen, P S
1995-07-01
This paper presents the results of a laboratory assessment of the performance of a new type of personal dosimeter, the Electronic Personal Dosemeter made by Siemens Plessey Controls Limited. Twenty pre-production dosimeters and a reader were purchased by Ontario Hydro for the assessment. Tests were performed on radiological performance, including reproducibility, accuracy, linearity, detection threshold, energy response, angular response, neutron response, and response time. There were also tests on the effects of a variety of environmental factors, such as temperature, humidity, pulsed magnetic and electric fields, low- and high-frequency electromagnetic fields, light exposure, drop impact, vibration, and splashing. Other characteristics that were tested were alarm volume, clip force, and battery life. The test results were compared with the relevant requirements of three standards: an Ontario Hydro standard for personal alarming dosimeters, an International Electrotechnical Commission draft standard for direct reading personal dose monitors, and an International Electrotechnical Commission standard for thermoluminescence dosimetry systems for personal monitoring. In general, the performance of the Electronic Personal Dosemeter was found to be quite acceptable: it met most of the relevant requirements of the three standards. However, the following deficiencies were found: slow response time; sensitivity to high-frequency electromagnetic fields; poor resistance to dropping; and an alarm that was not loud enough. In addition, the response of the electronic personal dosimeter to low-energy beta rays may be too low for some applications. Problems were experienced with the reliability of operation of the pre-production dosimeters used in these tests.
Memarian, Negar; Venetsanopoulos, Anastasios N; Chau, Tom
2011-01-01
This study reports a client-centred development of a non-contact access switch based on an infrared thermal imaging of mouth opening-closing activity of an individual with severe spastic quadriplegic cerebral palsy. Over a 6-month period, the client participated in five test sessions to inform the development of an infrared thermal switch. The client completed eight stimulus-response trials (switch test) and eight word-matching trials (scan test) using the infrared thermal switch and provided subjective feedback throughout. For the switch test, the client achieved an average correct activation rate of 90% and average response time of 2.4 s. His mean correct activation rate on the scan test improved from 65 to 80% over the course of system development, with an average response time of 11.7 s. An infrared thermography switch tuned to a client's extant orofacial gestures is a practical non-invasive access solution and warrants further research in clients with severe physical disability.
2013-01-01
Background Knowledge about tumour gene mutation status is essential for the treatment of increasing numbers of cancer patients, and testing quality has a major impact on treatment response and cost. In 2012, 4,629 tests for BRAF p.V600 were performed in France, in patients with melanomas. Methods Two batches of unstained melanoma sections were sent, in May and November 2012, to the 46 laboratories supported by the French National Institute of Cancer (INCa). An external quality assessment (EQA) evaluated mutation status, response times and compliance with INCa recommendations. Results All the French laboratories involved in testing participated in the EQA. Fourteen different methods were used to detect BRAF mutations, most consisting of combinations of in-house techniques. False responses were noted in 25/520 cases (4.8%), 11 of which concerned confusion between p.V600E and p.V600K. Thus, 2.7% of responses would have led to inappropriate treatment. Within six months, mean response times decreased from 22 to 12 days (P<0.001), and the percentage of samples evaluated by a pathologist for tumour cell content increased, from 75.2% to 96.9% (P<0.001). Conclusion Despite the use of non-certified methods, the false response rate was low. Nationwide EQA can improve the quality of molecular pathology tests on tumours. PMID:24119386
ERIC Educational Resources Information Center
Schmitt, T. A.; Sass, D. A.; Sullivan, J. R.; Walker, C. M.
2010-01-01
Imposed time limits on computer adaptive tests (CATs) can result in examinees having difficulty completing all items, thus compromising the validity and reliability of ability estimates. In this study, the effects of speededness were explored in a simulated CAT environment by varying examinee response patterns to end-of-test items. Expectedly,…
Statistical studies of animal response data from USF toxicity screening test method
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Machado, A. M.
1978-01-01
Statistical examination of animal response data obtained using Procedure B of the USF toxicity screening test method indicates that the data deviate only slightly from a normal or Gaussian distribution. This slight departure from normality is not expected to invalidate conclusions based on theoretical statistics. Comparison of times to staggering, convulsions, collapse, and death as endpoints shows that time to death appears to be the most reliable endpoint because it offers the lowest probability of missed observations and premature judgements.
Diniz, Cassiano R A F; Casarotto, Plínio C; Joca, Sâmia R L
2016-07-01
Hodological and genetic differences between dorsal (DH) and ventral (VH) hippocampus may convey distinct behavioral roles. DH is responsible for mediating cognitive process, such as learning and memory, while VH modulates neuroendocrine and emotional-motivational responses to stress. Manipulating glutamatergic NMDA receptors and nitric oxide (NO) systems of the hippocampus induces important changes in behavioral responses to stress. Nevertheless, there is no study concerning functional differences between DH and VH in the modulation of behavioral responses induced by stress models predictive of antidepressant effects. Thus, this study showed that reversible blockade of the DH or VH of animals submitted to the forced swimming test (FST), by using cobalt chloride (calcium-dependent synaptic neurotransmission blocker), was not able to change immobility time. Afterwards, the NMDA-NO system was evaluated in the FST by means of intra-DH or intra-VH administration of NMDA receptor antagonist (AP7), NOS1 and sGC inhibitors (N-PLA and ODQ, respectively). Bilateral intra-DH injections after pretest or before test were able to induce antidepressant-like effects in the FST. On the other hand, bilateral VH administration of AP-7, N-PLA and ODQ induced antidepressant-like effects only when injected before the test. Administration of NO scavenger (C-PTIO) intra-DH, after pretest and before test, or intra-VH before test induced similar results. Increased NOS1 levels was associated to stress exposure in the DH. These results suggest that the glutamatergic-NO system of the DH and VH are both able to modulate behavioral responses in the FST, albeit with differential participation along time after stress exposure. Copyright © 2016 Elsevier B.V. All rights reserved.
Azin, Mahdieh; Zangiabadi, Nasser; Moghadas Tabrizi, Yousef; Iranmanesh, Farhad; Baneshi, Mohammad Reza
2016-08-01
Mental rotation is a cognitive motor process which was impaired in different neurologic disorders. We investigated whether there were deficits in response pattern, reaction time and response accuracy rate of mental rotation in multiple sclerosis (MS) patients compared to healthy subjects and whether cognitive dysfunctions in MS patients were correlated with mental rotation deficits. Moreover, we showed whether there was a difference between upper and lower-limbs mental rotation in MS patients. Thirty-five MS patients and 25 healthy subjects performed hand mental rotation (HMR) and foot mental rotation (FMR) tasks. Visual information processing speed, spatial learning and memory ability, and visuospatial processing were assessed by Symbol Digit Modalities Test (SDMT), Brief Visuospatial Memory Test-Revised (BVMT-R), and Judgment of Line Orientation Test (JLO) respectively in MS patients. Reaction time for both hand and foot stimuli increased, and response accuracy rate for hand stimuli decreased in MS patients compared to healthy subjects, but response pattern of mental rotation in MS patients persisted. Similar to healthy subjects, MS patients performed upper-limbs mental rotation more easily than a lower-limbs mental rotation with more speed and response accuracy rate. Reaction time and response accuracy rate were correlated with the mentioned cognitive functions. MS patients made use of the correct response pattern for problem solving of increasing orientation from upright stimuli. Reaction time and response accuracy rate altered in these patients and this alteration might occur along with impairment in motor planning. Subjects' better responding to hand stimuli was due to more familiarity with hand stimuli. The correlation of mental rotation ability with cognitive functions indicates the possible role of cognitive functions in mental rotation.
Exercise Blood Pressure Guidelines: Time to Re-evaluate What is Normal and Exaggerated?
Currie, Katharine D; Floras, John S; La Gerche, Andre; Goodman, Jack M
2018-03-24
Blood pressure responses to graded exercise testing can provide important diagnostic and prognostic information. While published guidelines outline what constitutes a "normal" and "abnormal" (i.e., exaggerated) blood pressure response to exercise testing, the widespread use of exaggerated blood pressure responses as a clinical tool is limited due to sparse and inconsistent data. A review of the original sources from these guidelines reveals an overall lack of empirical evidence to support both the normal blood pressure responses and their upper limits. In this current opinion, we critically evaluate the current exercise blood pressure guidelines including (1) the normal blood pressure responses to graded exercise testing; (2) the upper limits of this normal response; (3) the blood pressure criteria for test termination; and (4) the thresholds for exaggerated blood pressure responses. We provide evidence that exercise blood pressure responses vary according to subject characteristics, and subsequently a re-evaluation of what constitutes normal and abnormal responses is necessary to strengthen the clinical utility of this assessment.
Optimizing the Use of Response Times for Item Selection in Computerized Adaptive Testing
ERIC Educational Resources Information Center
Choe, Edison M.; Kern, Justin L.; Chang, Hua-Hua
2018-01-01
Despite common operationalization, measurement efficiency of computerized adaptive testing should not only be assessed in terms of the number of items administered but also the time it takes to complete the test. To this end, a recent study introduced a novel item selection criterion that maximizes Fisher information per unit of expected response…
Abulebda, Kamal; Patel, Vinit J; Ahmed, Sheikh S; Tori, Alvaro J; Lutfi, Riad; Abu-Sultaneh, Samer
2017-10-28
The use of diagnostic auditory brainstem response testing under sedation is currently the "gold standard" in infants and young children who are not developmentally capable of completing the test. The aim of the study is to compare a propofol-ketamine regimen to an oral chloral hydrate regimen for sedating children undergoing auditory brainstem response testing. Patients between 4 months and 6 years who required sedation for auditory brainstem response testing were included in this retrospective study. Drugs doses, adverse effects, sedation times, and the effectiveness of the sedative regimens were reviewed. 73 patients underwent oral chloral hydrate sedation, while 117 received propofol-ketamine sedation. 12% of the patients in the chloral hydrate group failed to achieve desired sedation level. The average procedure, recovery and total nursing times were significantly lower in the propofol-ketamine group. Propofol-ketamine group experienced higher incidence of transient hypoxemia. Both sedation regimens can be successfully used for sedating children undergoing auditory brainstem response testing. While deep sedation using propofol-ketamine regimen offers more efficiency than moderate sedation using chloral hydrate, it does carry a higher incidence of transient hypoxemia, which warrants the use of a highly skilled team trained in pediatric cardio-respiratory monitoring and airway management. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Supin, Alexander Ya; Popov, Vladimir V
2015-05-01
Auditory evoked potentials (AEPs) were recorded in a beluga whale Delphinapterus leucas using a double-pulse stimulation paradigm, specifically measuring the recovery (release from masking) of the second (test) response as a function of delay after the first (conditioning) pulse at various levels of the conditioning and test stimuli. The conditioning/test stimulus level ratio influenced the recovery time (the higher the ratio, the longer the recovery). This interrelation was used to evaluate the intensity/time trade in release from forward masking. Trade was evaluated as 32.2 dB per time decade. Data were considered as simulating interactions between the transmitted pulse and echo during echolocation, assuming that a transmitted sonar pulse produces forward masking of the echo response. With increased target distance, the attenuation of the echo may be compensated by the release from masking. According to the model, the compensation results in substantial stabilization of the echo response even if the intensity/time trade of release from masking is not precisely equal to the rate of echo attenuation with distance.
NASA Astrophysics Data System (ADS)
Baker, Erik Reese
A repeated-measures, within-subjects design was conducted on 58 participant pilots to assess mean differences on energy management situation awareness response time and response accuracy between a conventional electronic aircraft display, a primary flight display (PFD), and an ecological interface design aircraft display, the OZ concept display. Participants were associated with a small Midwestern aviation university, including student pilots, flight instructors, and faculty with piloting experience. Testing consisted of observing 15 static screenshots of each cockpit display type and then selecting applicable responses from 27 standardized responses for each screen. A paired samples t-test was computed comparing accuracy and response time for the two displays. There was no significant difference in means between PFD Response Time and OZ Response Time. On average, mean PFD Accuracy was significantly higher than mean OZ Accuracy (MDiff = 13.17, SDDiff = 20.96), t(57) = 4.78, p < .001, d = 0.63. This finding showed operational potential for the OZ display, since even without first training to proficiency on the previously unseen OZ display, participant performance differences were not operationally remarkable. There was no significant correlation between PFD Response Time and PFD Accuracy, but there was a significant correlation between OZ Response Time and OZ Accuracy, r (58) = .353, p < .01. These findings suggest the participant familiarity of the PFD resulted in accuracy scores unrelated to response time, compared to the participants unaccustomed with the OZ display where longer response times manifested in greater understanding of the OZ display. PFD Response Time and PFD Accuracy were not correlated with pilot flight hours, which was not expected. It was thought that increased experience would translate into faster and more accurate assessment of the aircraft stimuli. OZ Response Time and OZ Accuracy were also not correlated with pilot flight hours, but this was expected. This was consistent with previous research that observed novice operators performing as well as experienced professional pilots on dynamic flight tasks with the OZ display. A demographic questionnaire and a feedback survey were included in the trial. An equivalent three-quarters majority of participants rated the PFD as "easy" and the OZ as "confusing", yet performance accuracy and response times between the two displays were not operationally different.
Calculating Nozzle Side Loads using Acceleration Measurements of Test-Based Models
NASA Technical Reports Server (NTRS)
Brown, Andrew M.; Ruf, Joe
2007-01-01
As part of a NASA/MSFC research program to evaluate the effect of different nozzle contours on the well-known but poorly characterized "side load" phenomena, we attempt to back out the net force on a sub-scale nozzle during cold-flow testing using acceleration measurements. Because modeling the test facility dynamics is problematic, new techniques for creating a "pseudo-model" of the facility and nozzle directly from modal test results are applied. Extensive verification procedures were undertaken, resulting in a loading scale factor necessary for agreement between test and model based frequency response functions. Side loads are then obtained by applying a wide-band random load onto the system model, obtaining nozzle response PSD's, and iterating both the amplitude and frequency of the input until a good comparison of the response with the measured response PSD for a specific time point is obtained. The final calculated loading can be used to compare different nozzle profiles for assessment during rocket engine nozzle development and as a basis for accurate design of the nozzle and engine structure to withstand these loads. The techniques applied within this procedure have extensive applicability to timely and accurate characterization of all test fixtures used for modal test.A viewgraph presentation on a model-test based pseudo-model used to calculate side loads on rocket engine nozzles is included. The topics include: 1) Side Loads in Rocket Nozzles; 2) Present Side Loads Research at NASA/MSFC; 3) Structural Dynamic Model Generation; 4) Pseudo-Model Generation; 5) Implementation; 6) Calibration of Pseudo-Model Response; 7) Pseudo-Model Response Verification; 8) Inverse Force Determination; 9) Results; and 10) Recent Work.
Test benches for studying the properties of car tyres
NASA Astrophysics Data System (ADS)
Kuznetsov, N. Yu.; Fedotov, A. I.; Vlasov, V. G.
2017-12-01
The article describes the design of the measuring systems of test benches used to study the properties of elastic tyres. The bench has two autonomous systems - for testing the braking properties of elastic tyres rolling in a plane parallel way and for testing tyre slip properties. The system for testing braking properties determines experimental characteristics of elastic tyres as the following dependencies: longitudinal response vs time, braking torque vs slip, angular velocity vs slip, and longitudinal response vs slip. The system for studying tyre slip properties determines both steady (dependence of the lateral response in a contact area on the slipping angle) and non-steady characteristics (time variation of the slipping angle as a result of turning from -40 to +40 degrees) of tyre slip. The article presents the diagrams of bench tests of elastic tyres. The experimental results show metrological parameters and functional capabilities of the bench for studying tyre properties in driving and braking modes. The metrological indices of the recorded parameters of the measuring system for studying tyre properties are presented in the table.
Age-related changes in human posture control: Motor coordination tests
NASA Technical Reports Server (NTRS)
Peterka, R. J.; Black, F. O.
1989-01-01
Postural responses to support surface displacements were measured in 214 normal human subjects ranging in age from 7 to 81 years. Motor tests measured leg muscle Electromyography (EMG) latencies, body sway, and the amplitude and timing of changes in center of pressure displacements in response to sudden forward and backward horizontal translations of the support surface upon which the subjects stood. There were small increases in both EMG latencies and the time to reach the peak amplitude of center of pressure responses with increasing age. The amplitude of center of pressure responses showed little change with age if the amplitude measures were normalized by a factor related to subject height. In general, postural responses to sudden translations showed minimal changes with age, and all age related trends which were identified were small relative to the variability within the population.
Response-Time Tests of Logical-Rule Models of Categorization
ERIC Educational Resources Information Center
Little, Daniel R.; Nosofsky, Robert M.; Denton, Stephen E.
2011-01-01
A recent resurgence in logical-rule theories of categorization has motivated the development of a class of models that predict not only choice probabilities but also categorization response times (RTs; Fific, Little, & Nosofsky, 2010). The new models combine mental-architecture and random-walk approaches within an integrated framework and…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-29
... Record Keepers: 100. Estimated Time per Record Keeper: 60 minutes. Estimated Total Burden Hours: 100... or record keepers from the collection of information (total capital/ startup costs and operations and.... Estimated Number of Responses per Respondent: 1. Estimated Number of Total Responses: 100. Estimated Time...
Spinning Reserve from Responsive Load
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kueck, John D; Kirby, Brendan J; Laughner, T
2009-01-01
As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host a spinning reserve test. The Tennessee Valley Authority (TVA) supplied real-time metering and monitoring expertise to record total hotel load during both normal operations and testing. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. The load drop was very rapid, essentially as fast as the 2 second metering couldmore » detect.« less
Eechaute, Christophe; Vaes, Peter; Duquet, William; Van Gheluwe, Bart
2009-07-01
Studies investigating peroneal muscle reaction times in chronically unstable ankle joints present conflicting results. The degree of reliability and accuracy of these measurements is unknown in patients with chronic ankle instability (CAI). 40 patients with CAI and 30 healthy subjects were tested using a sudden ankle inversion of 50 degrees while standing on a trapdoor device. Sudden ankle inversion measurements were registered using electromyography, accelerometry and electrogoniometry. For reliability testing, intra-class coefficients (ICCs; model 3,1) and standard errors of measurements of the latency time, motor response time and electromechanical delay of the peroneus longus muscle, the time and angular position of onset of decelerations, the mean and maximum inversion speed and the total inversion time were calculated in 15 patients with CAI. To assess between-group differences, t-tests for independent samples (p<.05) were used. ICCs ranged from .20 (angular position of onset of the second deceleration) to .98 (electromechanical delay of the peroneus longus muscle). Significant between-group differences were observed in only 2 of the 12 variables (for the electromechanical delay of the peroneus longus muscle, p=.001; time of onset of the second deceleration, p=.040). The latency time and motor response time of the peroneus longus muscle, the total inversion time and the mean inversion speed demonstrate acceptable reliability in healthy subjects and patients. The latency time and motor response time of the peroneus longus muscle are not delayed in patients with CAI. Ankle inversion measurements are not discriminative for CAI.
Young Learners' Response Processes When Taking Computerized Tasks for Speaking Assessment
ERIC Educational Resources Information Center
Lee, Shinhye; Winke, Paula
2018-01-01
We investigated how young language learners process their responses on and perceive a computer-mediated, timed speaking test. Twenty 8-, 9-, and 10-year-old non-native English-speaking children (NNSs) and eight same-aged, native English-speaking children (NSs) completed seven computerized sample TOEFL® Primary™ speaking test tasks. We investigated…
Young, Kymberly D; Misaki, Masaya; Harmer, Catherine J; Victor, Teresa; Zotev, Vadim; Phillips, Raquel; Siegle, Greg J; Drevets, Wayne C; Bodurka, Jerzy
2017-10-15
In participants with major depressive disorder who are trained to upregulate their amygdalar hemodynamic responses during positive autobiographical memory recall with real-time functional magnetic resonance imaging neurofeedback (rtfMRI-nf) training, depressive symptoms diminish. This study tested whether amygdalar rtfMRI-nf also changes emotional processing of positive and negative stimuli in a variety of behavioral and imaging tasks. Patients with major depressive disorder completed two rtfMRI-nf sessions (18 received amygdalar rtfMRI-nf, 16 received control parietal rtfMRI-nf). One week before and following rtfMRI-nf training, participants performed tasks measuring responses to emotionally valenced stimuli including a backward-masking task, which measures the amygdalar hemodynamic response to emotional faces presented for traditionally subliminal duration and followed by a mask, and the Emotional Test Battery in which reaction times and performance accuracy are measured during tasks involving emotional faces and words. During the backward-masking task, amygdalar responses increased while viewing masked happy faces but decreased to masked sad faces in the experimental versus control group following rtfMRI-nf. During the Emotional Test Battery, reaction times decreased to identification of positive faces and during self-identification with positive words and vigilance scores increased to positive faces and decreased to negative faces during the faces dot-probe task in the experimental versus control group following rtfMRI-nf. rtfMRI-nf training to increase the amygdalar hemodynamic response to positive memories was associated with changes in amygdalar responses to happy and sad faces and improved processing of positive stimuli during performance of the Emotional Test Battery. These results may suggest that amygdalar rtfMRI-nf training alters responses to emotional stimuli in a manner similar to antidepressant pharmacotherapy. Copyright © 2017 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.
Frýbort, Pavel; Kokštejn, Jakub; Musálek, Martin; Süss, Vladimír
2016-06-01
A soccer player's capability to control and manage his behaviour in a game situation is a prerequisite, reflecting not only swift and accurate tactical decision-making, but also prompt implementation of a motor task during intermittent exercise conditions. The purpose of this study was to analyse the relationship between varying exercise intensity and the visual-motor response time and the accuracy of motor response in an offensive game situation in soccer. The participants (n = 42) were male, semi-professional, soccer players (M age 18.0 ± 0.9 years) and trained five times a week. Each player performed four different modes of exercise intensity on the treadmill (motor inactivity, aerobic, intermittent and anaerobic activity). After the end of each exercise, visual-motor response time and accuracy of motor response were assessed. Players' motion was captured by digital video camera. ANOVA indicated no significant difference (p = 0.090) in the accuracy of motor response between the four exercise intensity modes. Practical significance (Z-test = 0.31) was found in visual-motor response time between exercise with dominant involvement of aerobic metabolism, and intense intermittent exercise. A medium size effect (Z-test = 0.34) was also found in visual-motor response time between exercise with dominant involvement of aerobic metabolism and exercise with dominant involvement of anaerobic metabolism, which was confirmed by ANOVA (897.02 ± 57.46 vs. 940.95 ± 71.14; p = 0.002). The results showed that different modes of exercise intensity do not adversely affect the accuracy of motor responses; however, high-intensity exercise has a negative effect on visual-motor response time in comparison to moderate intensity exercise. Key pointsDifferent exercise intensity modes did not affect the accuracy of motor response.Anaerobic, highly intensive short-term exercise significantly decreased the visual-motor response time in comparison with aerobic exercise.Further research should focus on the assessment of VMRT from a player's real - field position view rather than a perspective view.
Test-retest reliability of the multifocal photopic negative response.
Van Alstine, Anthony W; Viswanathan, Suresh
2017-02-01
To assess the test-retest reliability of the multifocal photopic negative response (mfPhNR) of normal human subjects. Multifocal electroretinograms were recorded from one eye of 61 healthy adult subjects on two separate days using a Visual Evoked Response Imaging System software version 4.3 (EDI, San Mateo, California). The visual stimulus delivered on a 75-Hz monitor consisted of seven equal-sized hexagons each subtending 12° of visual angle. The m-step exponent was 9, and the m-sequence was slowed to include at least 30 blank frames after each flash. Only the first slice of the first-order kernel was analyzed. The mfPhNR amplitude was measured at a fixed time in the trough from baseline (BT) as well as at the same fixed time in the trough from the preceding b-wave peak (PT). Additionally, we also analyzed BT normalized either to PT (BT/PT) or to the b-wave amplitude (BT/b-wave). The relative reliability of test-retest differences for each test location was estimated by the Wilcoxon matched-pair signed-rank test and intraclass correlation coefficients (ICC). Absolute test-retest reliability was estimated by Bland-Altman analysis. The test-retest amplitude differences for neither of the two measurement techniques were statistically significant as determined by Wilcoxon matched-pair signed-rank test. PT measurements showed greater ICC values than BT amplitude measurements for all test locations. For each measurement technique, the ICC value of the macular response was greater than that of the surrounding locations. The mean test-retest difference was close to zero for both techniques at each of the test locations, and while the coefficient of reliability (COR-1.96 times the standard deviation of the test-retest difference) was comparable for the two techniques at each test location when expressed in nanovolts, the %COR (COR normalized to the mean test and retest amplitudes) was superior for PT than BT measurements. The ICC and COR were comparable for the BT/PT and BT/b-wave ratios and were better than the ICC and COR for BT but worse than PT. mfPhNR amplitude measured at a fixed time in the trough from the preceding b-wave peak (PT) shows greater test-retest reliability when compared to amplitude measurement from baseline (BT) or BT amplitude normalized to either the PT or b-wave amplitudes.
Coad, Michael; Clifford, Derek; Rhodes, Shelley G; Hewinson, R Glyn; Vordermeier, H Martin; Whelan, Adam O
2010-01-01
The principal surveillance tool used to control bovine tuberculosis in cattle is the removal of animals that provide a positive response to the tuberculin skin-test. In this study we performed a longitudinal investigation of the immunological and diagnostic consequences of repeated short-interval skin-tests in cattle naturally infected with Mycobacterium bovis. Tuberculin skin-test positive cattle were subjected to up to four further intradermal comparative cervical skin-tests at approximately 60-day intervals. A significant progressive reduction in the strength of the skin-test was observed after successive tests. In contrast, the magnitude of interferon-gamma (IFN-gamma) responses was not influenced by repeat skin-testing either transiently around the time of each skin-test or longitudinally following repeated tests. A significant boost in blood interleukin-10 (IL-10) production was observed within 3 days following each skin-test although the magnitude of this boosted response returned to lower levels by day 10 post-test. The application of a novel multiplex assay to simultaneously measure seven cytokines and chemokines also identified that skin-testing resulted in a significant and progressive reduction in antigen specific interleukin-1beta (IL-1beta) whilst confirming stable IFN-gamma and elevated IL-10 responses in the blood. Therefore, we have demonstrated that in cattle naturally infected with M. bovis, repeat short-interval skin-testing can lead to a progressive reduction in skin-test responsiveness which has potential negative consequences for the detection of infected animals with marginal or inconclusive skin-test responses. The desensitising effect is associated with decreased IL-1beta and elevated IL-10 responses, but importantly, does not influence antigen specific IFN-gamma responses. INRA, EDP Sciences, 2009
Morningness/eveningness and the synchrony effect for spatial attention.
Dorrian, Jillian; McLean, Benjamin; Banks, Siobhan; Loetscher, Tobias
2017-02-01
There is evidence that a decrease in alertness is associated with a rightward shift of attention. Alertness fluctuates throughout the day and peak times differ between individuals. Some individuals feel most alert in the morning; others in the evening. Our aim was to investigate the influence of morningness/eveningness and time of testing on spatial attention. It was predicted that attention would shift rightwards when individuals were tested at their non-optimal time as compared to tests at peak times. A crowdsourcing internet marketplace, Amazon Mechanical Turk (AMT) was used to collect data. Given questions surrounding the quality of data drawn from such virtual environments, this study also investigated the sensitivity of data to demonstrate known effects from the literature. Five-hundred and thirty right-handed participants took part between 6 am and 11 pm. Participants answered demographic questions, completed a question from the Horne and Östberg Morningness/Eveningness Scale, and performed a spatial attentional task (landmark task). For the landmark task, participants indicated whether the left or right segment of each of 72 pre-bisected lines was longer (longer side counterbalanced). Response bias was calculated by subtracting the 'number of left responses' from the 'number of right responses', and dividing by the number of trials. Negative values indicate a leftward attentional bias, and positive values a rightward bias. Well-supported relationships between variables were reflected in the dataset. Controlling for age, there was a significant interaction between morningness/eveningness and time of testing (morning=6 am-2.30 pm, evening=2.30 pm-11 pm) (p<0.05) such that there was a relative rightward shift of attention from peak to off-peak times of testing for those identifying as morning types, but not evening types. Findings support the utility of crowdsourcing internet marketplaces as data collection vehicles for research. Results also suggest that the deployment of spatial attention is modulated by an individual's peak time (morningness/eveningness) and time of testing. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Reis, Louis G.
With the increasing prevalence of diabetes in the United States and worldwide, blood glucose monitoring must be accurate and reliable. Current enzymatic sensors have numerous disadvantages that make them unreliable and unfavorable among patients. Recent research in glucose affinity sensors correct some of the problems that enzymatic sensors experience. Dextran and concanavalin A are two of the more common components used in glucose affinity sensors. When these sensors were first explored, a model was derived to predict the response time of a glucose affinity sensor using concanavalin A and dextran. However, the model assumed the system was linear and fell short of calculating times representative of the response times determined through experimental tests with the sensors. In this work, a new model that uses the Stokes-Einstein Equation to demonstrate the nonlinear behavior of the glucose affinity assay was developed to predict the response times of similar glucose affinity sensors. In addition to the device tested by the original linear model, additional devices were identified and tested with the proposed model. The nonlinear model was designed to accommodate the many different variations between systems. The proposed model was able to accurately calculate response times for sensors using the concanavalin A-dextran affinity assay with respect to the experimentally reported times by the independent research groups. Parameter studies using the nonlinear model were able to identify possible setbacks that could compromise the response of thesystem. Specifically, the model showed that the improper use of asymmetrical membranes could increase the response time by as little as 20% or more as the device is miniaturized. The model also demonstrated that systems using the concanavalin Adextran assay would experience higher response times in the hypoglycemic range. This work attempted to replicate and improve an osmotic glucose affinity sensor. The system was designed to negate additional effects that could cause artifacts or irregular readings such as external osmotic differences and external pressure differences. However, the experimental setup and execution faced numerous setbacks that highlighted the additional difficulty that sensors using asymmetrical ceramic membranes and the concanavalin A-dextran affinity assay may experience.
Laboratory testing of alcohol safety interlock systems employing divided attention tests
DOT National Transportation Integrated Search
1975-12-01
Author's abstract: Prototype Alcohol Safety Interlock Systems employing measurements of tracking ability, reaction time, and response accuracy to discern alcohol impairment were submitted to laboratory testing. These systems were modified versions of...
Noninvasive stress testing - Methodology for elimination of the phonocardiogram
NASA Technical Reports Server (NTRS)
Spodick, D. H.; Lance, V. Q.
1976-01-01
Measurement by systolic time intervals (STI) of cardiac responses requires extremely careful recording during actual stress test performance. Previous work indicated no significant changes in the pulse transmission time (PTT) during exercise and other challenges. Since external STI depend on the carotid pulse offset by the PTT as an aortic curve equivalent, stable PTT implies that timing of the carotid upstroke and the carotid incisura would respectively track the pre-ejection period and the aortic incisura. In ten subjects, STIs were recorded at supine rest, sitting, standing, during prompt and sustained squatting and during isometric and dynamic exercise. The results demonstrated the tracking of both points. Coefficients of correlation and of determination were uniformly high for all challenges except isometric handgrip (IHG). Since left ventricular ejection time is obtained directly from the pulse curve, with the exception of IHG, STI responses during stress testing can be measured without a phonocardiogram.
NASA Astrophysics Data System (ADS)
Fischer, P.; Jardani, A.; Cardiff, M.; Lecoq, N.; Jourde, H.
2018-04-01
In a karstic field, the flow paths are very complex as they globally follow the conduit network. The responses generated from an investigation in this type of aquifer can be spatially highly variable. Therefore, the aim of the investigation in this case is to define a degree of connectivity between points of the field, in order to understand these flow paths. Harmonic pumping tests represent a possible investigation method for characterizing the subsurface flow of groundwater. They have several advantages compared to a constant-rate pumping (more signal possibilities, ease of extracting the signal in the responses and possibility of closed loop investigation). We show in this work that interpreting the responses from a harmonic pumping test is very useful for delineating a degree of connectivity between measurement points. We have firstly studied the amplitude and phase offset of responses from a harmonic pumping test in a theoretical synthetic modeling case in order to define a qualitative interpretation method in the time and frequency domains. Three different type of responses have been separated: a conduit connectivity response, a matrix connectivity, and a dual connectivity (response of a point in the matrix, but close to a conduit). We have then applied this method to measured responses at a field research site. Our interpretation method permits a quick and easy reconstruction of the main flow paths, and the whole set of field responses appear to give a similar range of responses to those seen in the theoretical synthetic case.
Systems for measuring response statistics of gigahertz bandwidth photomultipliers
NASA Technical Reports Server (NTRS)
Abshire, J. B.; Rowe, H. E.
1977-01-01
New systems have been developed for measuring the average impulse response, the pulse-height spectrum, the transit-time statistics as a function of signal level, and the dark-count spectrum of gigahertz bandwidth photomultipliers. Measurements showed that the 0.53 microns pulse used as an optical test source had a 30 picoseconds and less than 70 ps pulse width. Calibration data showed the system resolution to be less than 20 ps for root mean square transit-time measurements. Test data for a static crossed-field photomultiplier showed 2-photoelectron resolution and less than 30-ps time jitter over the 1- to 100-photoelectron range.
Is children's listening effort in background noise influenced by the speaker's voice quality?
Sahlén, Birgitta; Haake, Magnus; von Lochow, Heike; Holm, Lucas; Kastberg, Tobias; Brännström, K Jonas; Lyberg-Åhlander, Viveka
2018-07-01
The present study aims at exploring the influence of voice quality on listening effort in children performing a language comprehension test with sentences of increasing difficulty. Listening effort is explored in relation to gender ( = cisgender). The study has a between-groups design. Ninety-three mainstreamed children aged 8;2 to 9;3 with typical language development participated. The children were randomly assigned to two groups (n = 46/47) with equal allocation of boys and girls and for the analysis to four groups depending of gender and voice condition. Working memory capacity and executive functions were tested in quiet. A digital version of a language comprehension test (the TROG-2) was used to measure the effect of voice quality on listening effort, measured as response time in a forced-choice paradigm. The groups listened to sentences through recordings of the same female voice, one group with a typical voice and one with a dysphonic voice, both in competing multi-talker babble noise. Response times were logged after a time buffer between the sentence-ending and indication of response. There was a significant increase in response times with increased task difficulty and response times between the two voice conditions differed significantly. The girls in the dysphonic condition were slower with increasing task difficulty. A dysphonic voice clearly adds to the noise burden and listening effort is greater in girls than in boys when the teacher speaks with dysphonic voice in a noisy background. These findings might mirror gender differences as for coping strategies in challenging contexts and have important implications for education.
NASA Technical Reports Server (NTRS)
Proctor, Margaret P.; Gunter, Edgar J.
2007-01-01
A case study of a high-speed seal test rotor shows how rotor dynamic analysis can be used to diagnose the source of high vibrations and evaluate a proposed remedy. Experimental results are compared with the synchronous and non-synchronous whirl response analysis of a double overhung, high-speed seal test rotor with ball bearings supported in 5.84- and 12.7-mm-long, un-centered squeeze-film oil dampers. Test performance with the original damper of length 5.84 mm was marginal. Non-synchronous whirling occurred at the overhung seal test disk and there was a high amplitude synchronous response near the drive spline above 32,000 rpm. Nonlinear synchronous unbalance and time transient whirl studies were conducted on the seal test rotor with the original and extended damper lengths. With the original damper design, the nonlinear synchronous response showed that unbalance could cause damper lockup at 33,000 rpm. Alford cross-coupling forces were also included at the overhung seal test disk for the whirl analysis. Sub-synchronous whirling at the seal test disk was observed in the nonlinear time transient analysis. With the extended damper length of 12.7 mm, the sub-synchronous motion was eliminated and the rotor unbalance response was acceptable to 45,000 rpm with moderate rotor unbalance. Seal test rotor orbits and vibration levels with the extended squeeze film dampers showed smooth operation to 40,444 rpm.
Evaluation of a Singular Value Decomposition Approach for Impact Dynamic Data Correlation
NASA Technical Reports Server (NTRS)
Horta, Lucas G.; Lyle, Karen H.; Lessard, Wendy B.
2003-01-01
Impact dynamic tests are used in the automobile and aircraft industries to assess survivability of occupants during crash, to assert adequacy of the design, and to gain federal certification. Although there is no substitute for experimental tests, analytical models are often developed and used to study alternate test conditions, to conduct trade-off studies, and to improve designs. To validate results from analytical predictions, test and analysis results must be compared to determine the model adequacy. The mathematical approach evaluated in this paper decomposes observed time responses into dominant deformation shapes and their corresponding contribution to the measured response. To correlate results, orthogonality of test and analysis shapes is used as a criterion. Data from an impact test of a composite fuselage is used and compared to finite element predictions. In this example, the impact response was decomposed into multiple shapes but only two dominant shapes explained over 85% of the measured response
Cardiovascular responses in type A and type B men to a series of stressors.
Ward, M M; Chesney, M A; Swan, G E; Black, G W; Parker, S D; Rosenman, R H
1986-02-01
Fifty-six healthy adult males were administered the Type A Structured Interview and assessed as exhibiting either Type A (N = 42) or Type B (N = 14) behavior pattern. They were monitored for systolic (SBP) and diastolic blood pressure (DBP) and heart rate (HR) responses during a series of six challenging tasks: Mental Arithmetic, Hypothesis Testing, Reaction Time, Video Game, Handgrip, and Cold Pressor. The results indicated that Type A subjects exhibited greater cardiovascular responses than did Type B subjects during some (Hypothesis Testing, Reaction Time, Video Game and Mental Arithmetic) but not all (Handgrip and Cold Pressor) of the tasks. These results are discussed in terms of previously reported findings on conditions that do and do not produce differences in Type A/B cardiovascular stress responses.
Evaluation of acoustic testing techniques for spacecraft systems
NASA Technical Reports Server (NTRS)
Cockburn, J. A.
1971-01-01
External acoustic environments, structural responses, noise reductions, and the internal acoustic environments have been predicted for a typical shroud/spacecraft system during lift-off and various critical stages of flight. Spacecraft responses caused by energy transmission from the shroud via mechanical and acoustic paths have been compared and the importance of the mechanical path has been evaluated. Theoretical predictions have been compared extensively with available laboratory and in-flight measurements. Equivalent laboratory acoustic fields for simulation of shroud response during the various phases of flight have been derived and compared in detail. Techniques for varying the time-space correlations of laboratory acoustic fields have been examined, together with methods for varying the time and spatial distribution of acoustic amplitudes. Possible acoustic testing configurations for shroud/spacecraft systems have been suggested and trade-off considerations have been reviewed. The problem of simulating the acoustic environments versus simulating the structural responses has been considered and techniques for testing without the shroud installed have been discussed.
Test Generation Algorithm for Fault Detection of Analog Circuits Based on Extreme Learning Machine
Zhou, Jingyu; Tian, Shulin; Yang, Chenglin; Ren, Xuelong
2014-01-01
This paper proposes a novel test generation algorithm based on extreme learning machine (ELM), and such algorithm is cost-effective and low-risk for analog device under test (DUT). This method uses test patterns derived from the test generation algorithm to stimulate DUT, and then samples output responses of the DUT for fault classification and detection. The novel ELM-based test generation algorithm proposed in this paper contains mainly three aspects of innovation. Firstly, this algorithm saves time efficiently by classifying response space with ELM. Secondly, this algorithm can avoid reduced test precision efficiently in case of reduction of the number of impulse-response samples. Thirdly, a new process of test signal generator and a test structure in test generation algorithm are presented, and both of them are very simple. Finally, the abovementioned improvement and functioning are confirmed in experiments. PMID:25610458
Unnanuntana, Aasis; Ruangsomboon, Pakpoom; Keesukpunt, Worawut
2018-06-01
The 2-minute walk test (2mwt) is a performance-based test that evaluates functional recovery after total knee arthroplasty (TKA). This study evaluated its validity compared with the modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), modified Knee Score, Numerical Pain Rating Scale, and Timed Up and Go test, and its responsiveness in assessing functional recovery in TKA patients. This prospective cohort study included 162 patients undergoing primary TKA between 2013 and 2015. We used patient-reported outcome measures (modified WOMAC, OKS, modified Knee Score, Numerical Pain Rating Scale) and performance-based tests (2mwt and Timed Up and Go test) at baseline and 3, 6, and 12 months postoperatively. The construct validity of 2mwt was determined between the 2mwt distances walked and other outcome measurements. To assess responsiveness, effect size and standardized response mean were analyzed. Minimal clinically important difference of 2mwt at 12 months after TKA was also calculated. All outcome measurements improved significantly from baseline to 3, 6, and 12 months postoperatively. Bivariate analysis revealed mild to moderate associations between the 2mwt and modified WOMAC function subscales, and moderate to strong associations with OKS. Mild to moderate correlations were found for pain and stiffness between 2mwt and other outcome measurements. The effect size and standardized response mean at 12 months were large, with a minimal clinically important difference of 12.7 m. 2mwt is a validated performance-based test with responsiveness properties. Being simple and easy to perform, it can be used routinely in clinical practice to evaluate functional recovery after TKA. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Special Tests for Monitoring Fetal Health
... a nonstress test? The nonstress test measures the fetal heart rate in response to fetal movement over time. The ... A belt with a sensor that measures the fetal heart rate is placed around your abdomen. The fetal heart ...
Behavioral momentum and resurgence: Effects of time in extinction and repeated resurgence tests
Shahan, Timothy A.
2014-01-01
Resurgence is an increase in a previously extinguished operant response that occurs if an alternative reinforcement introduced during extinction is removed. Shahan and Sweeney (2011) developed a quantitative model of resurgence based on behavioral momentum theory that captures existing data well and predicts that resurgence should decrease as time in extinction and exposure to the alternative reinforcement increases. Two experiments tested this prediction. The data from Experiment 1 suggested that without a return to baseline, resurgence decreases with increased exposure to alternative reinforcement and to extinction of the target response. Experiment 2 tested the predictions of the model across two conditions, one with constant alternative reinforcement for five sessions, and the other with alternative reinforcement removed three times. In both conditions, the alternative reinforcement was removed for the final test session. Experiment 2 again demonstrated a decrease in relapse across repeated resurgence tests. Furthermore, comparably little resurgence was observed at the same time point in extinction in the final test, despite dissimilar previous exposures to alternative reinforcement removal. The quantitative model provided a good description of the observed data in both experiments. More broadly, these data suggest that increased exposure to extinction may be a successful strategy to reduce resurgence. The relationship between these data and existing tests of the effect of time in extinction on resurgence is discussed. PMID:23982985
Imura, Tomoya; Takamura, Masahiro; Okazaki, Yoshihiro; Tokunaga, Satoko
2016-10-01
We developed a scale to measure time management and assessed its reliability and validity. We then used this scale to examine the impact of time management on psychological stress response. In Study 1-1, we developed the scale and assessed its internal consistency and criterion-related validity. Findings from a factor analysis revealed three elements of time management, “time estimation,” “time utilization,” and “taking each moment as it comes.” In Study 1-2, we assessed the scale’s test-retest reliability. In Study 1-3, we assessed the validity of the constructed scale. The results indicate that the time management scale has good reliability and validity. In Study 2, we performed a covariance structural analysis to verify our model that hypothesized that time management influences perceived control of time and psychological stress response, and perceived control of time influences psychological stress response. The results showed that time estimation increases the perceived control of time, which in turn decreases stress response. However, we also found that taking each moment as it comes reduces perceived control of time, which in turn increases stress response.
ERIC Educational Resources Information Center
Billiet, Cassandra R.; Bellis, Teri James
2011-01-01
Purpose: Studies using speech stimuli to elicit electrophysiologic responses have found approximately 30% of children with language-based learning problems demonstrate abnormal brainstem timing. Research is needed regarding how these responses relate to performance on behavioral tests of central auditory function. The purpose of the study was to…
Item Type and Gender Differences on the Mental Rotations Test
ERIC Educational Resources Information Center
Voyer, Daniel; Doyle, Randi A.
2010-01-01
This study investigated gender differences on the Mental Rotations Test (MRT) as a function of item and response types. Accordingly, 86 male and 109 female undergraduate students completed the MRT without time limits. Responses were coded as reflecting two correct (CC), one correct and one wrong (CW), two wrong (WW), one correct and one blank…
ERIC Educational Resources Information Center
Hendrickson, Amy; Patterson, Brian; Ewing, Maureen
2010-01-01
The psychometric considerations and challenges associated with including constructed response items on tests are discussed along with how these issues affect the form assembly specifications for mixed-format exams. Reliability and validity, security and fairness, pretesting, content and skills coverage, test length and timing, weights, statistical…
Linking Outcomes from Peabody Picture Vocabulary Test Forms Using Item Response Models
ERIC Educational Resources Information Center
Hoffman, Lesa; Templin, Jonathan; Rice, Mabel L.
2012-01-01
Purpose: The present work describes how vocabulary ability as assessed by 3 different forms of the Peabody Picture Vocabulary Test (PPVT; Dunn & Dunn, 1997) can be placed on a common latent metric through item response theory (IRT) modeling, by which valid comparisons of ability between samples or over time can then be made. Method: Responses…
ERIC Educational Resources Information Center
Sahin, Füsun
2017-01-01
Examining the testing processes, as well as the scores, is needed for a complete understanding of validity and fairness of computer-based assessments. Examinees' rapid-guessing and insufficient familiarity with computers have been found to be major issues that weaken the validity arguments of scores. This study has three goals: (a) improving…
Time domain modal identification/estimation of the mini-mast testbed
NASA Technical Reports Server (NTRS)
Roemer, Michael J.; Mook, D. Joseph
1991-01-01
The Mini-Mast is a 20 meter long 3-dimensional, deployable/retractable truss structure designed to imitate future trusses in space. Presented here are results from a robust (with respect to measurement noise sensitivity), time domain, modal identification technique for identifying the modal properties of the Mini-Mast structure even in the face of noisy environments. Three testing/analysis procedures are considered: sinusoidal excitation near resonant frequencies of the Mini-Mast, frequency response function averaging of several modal tests, and random input excitation with a free response period.
Tarkan, Sureyya; Plaisant, Catherine; Shneiderman, Ben; Hettinger, A. Zachary
2011-01-01
Researchers have conducted numerous case studies reporting the details on how laboratory test results of patients were missed by the ordering medical providers. Given the importance of timely test results in an outpatient setting, there is limited discussion of electronic versions of test result management tools to help clinicians and medical staff with this complex process. This paper presents three ideas to reduce missed results with a system that facilitates tracking laboratory tests from order to completion as well as during follow-up: (1) define a workflow management model that clarifies responsible agents and associated time frame, (2) generate a user interface for tracking that could eventually be integrated into current electronic health record (EHR) systems, (3) help identify common problems in past orders through retrospective analyses. PMID:22195201
Graphite Ablation and Thermal Response Simulation Under Arc-Jet Flow Conditions
NASA Technical Reports Server (NTRS)
Chen, Y.-K.; Milos, F. S.; Reda, D. C.; Stewart, D. A.; Venkatapathy, Ethiraj (Technical Monitor)
2002-01-01
The Two-dimensional Implicit Thermal Response and Ablation program, TITAN, was developed and integrated with a Navier-Stokes solver, GIANTS, for multidimensional ablation and shape change simulation of thermal protection systems in hypersonic flow environments. The governing equations in both codes are demoralized using the same finite-volume approximation with a general body-fitted coordinate system. Time-dependent solutions are achieved by an implicit time marching technique using Gauess-Siedel line relaxation with alternating sweeps. As the first part of a code validation study, this paper compares TITAN-GIANTS predictions with thermal response and recession data obtained from arc-jet tests recently conducted in the Interaction Heating Facility (IHF) at NASA Ames Research Center. The test models are graphite sphere-cones. Graphite was selected as a test material to minimize the uncertainties from material properties. Recession and thermal response data were obtained from two separate arc-jet test series. The first series was at a heat flux where graphite ablation is mainly due to sublimation, and the second series was at a relatively low heat flux where recession is the result of diffusion-controlled oxidation. Ablation and thermal response solutions for both sets of conditions, as calculated by TITAN-GIANTS, are presented and discussed in detail. Predicted shape change and temperature histories generally agree well with the data obtained from the arc-jet tests.
NASA Technical Reports Server (NTRS)
Allen, R. W.; Jex, H. R.
1973-01-01
In order to test various components of a regenerative life support system and to obtain data on the physiological and psychological effects of long duration exposure to confinement in a space station atmosphere, four carefully screened young men were sealed in a space station simulator for 90 days and administered a tracking test battery. The battery included a clinical test (Critical Instability Task) designed to measure a subject's dynamic time delay, and a more conventional steady tracking task, during which dynamic response (describing functions) and performance measures were obtained. Good correlation was noted between the clinical critical instability scores and more detailed tracking parameters such as dynamic time delay and gain-crossover frequency. The levels of each parameter span the range observed with professional pilots and astronaut candidates tested previously. The chamber environment caused no significant decrement on the average crewman's dynamic response behavior, and the subjects continued to improve slightly in their tracking skills during the 90-day confinement period.
Adults' past-day recall of sedentary time: reliability, validity, and responsiveness.
Clark, Bronwyn K; Winkler, Elisabeth; Healy, Genevieve N; Gardiner, Paul G; Dunstan, David W; Owen, Neville; Reeves, Marina M
2013-06-01
Past-day recall rather than recall of past week or a usual/typical day may improve the validity of self-reported sedentary time measures. This study examined the test-retest reliability, criterion validity, and responsiveness of the seven-item questionnaire, Past-day Adults' Sedentary Time (PAST). Participants (breast cancer survivors, n = 90, age = 33-75 yr, body mass index = 25-40 kg·m) in a 6-month randomized controlled trial of a lifestyle-based weight loss intervention completed the interviewer-administered PAST questionnaire about time spent sitting/lying on the previous day for work, transport, television viewing, nonwork computer use, reading, hobbies, and other purposes (summed for total sedentary time). The instrument was administered at baseline, 7 d later for test-retest reliability (n = 86), and at follow-up. ActivPAL3-assessed sit/lie time in bouts of ≥5 min during waking hours on the recall day was used as the validity criterion measure at both baseline (n = 72) and follow-up (n = 68). Analyses included intraclass correlation coefficients, Pearson's correlations (r), and Bland-Altman plots and responsiveness index. The PAST had fair to good test-retest reliability (intraclass correlation coefficient = 0.50, 95% confidence interval [CI] = 0.32-0.64). At baseline, the correlation between PAST and activPAL sit/lie time was r = 0.57 (95% CI = 0.39-0.71). The mean difference between PAST at baseline and retest was -25 min (5.2%), 95% limits of agreement = -5.9 to 5.0 h, and the activPAL sit/lie time was -9 min (1.8%), 95% limits of agreement = -4.9 to 4.6 h. The PAST showed small but significant responsiveness (-0.44, 95% CI = -0.92 to -0.04); responsiveness of activPAL sit/lie time was not significant. The PAST questionnaire provided an easy-to-administer measure of sedentary time in this sample. Validity and reliability findings compare favorably with other sedentary time questionnaires. Past-day recall of sedentary time shows promise for use in future health behavior, epidemiological, and population surveillance studies.
ERIC Educational Resources Information Center
Agoston, Anna M.; Rudolph, Karen D.
2011-01-01
This study examined transactional associations between responses to peer stress and depression in youth. Specifically, it tested the hypotheses that (a) depression would predict fewer effortful responses and more involuntary, dysregulated responses to peer stress over time; and (b) fewer adaptive and more maladaptive responses would predict…
Kim, Bung-Nyun; Kim, Jae-Won; Cummins, Tarrant D R; Bellgrove, Mark A; Hawi, Ziarih; Hong, Soon-Beom; Yang, Young-Hui; Kim, Hyo-Jin; Shin, Min-Sup; Cho, Soo-Churl; Kim, Ji-Hoon; Son, Jung-Woo; Shin, Yun-Mi; Chung, Un-Sun; Han, Doug-Hyun
2013-06-01
Noradrenergic dysfunction may be associated with cognitive impairments in attention-deficit/hyperactivity disorder (ADHD), including increased response time variability, which has been proposed as a leading endophenotype for ADHD. The aim of this study was to examine the relationship between polymorphisms in the α-2A-adrenergic receptor (ADRA2A) and norepinephrine transporter (SLC6A2) genes and attentional performance in ADHD children before and after pharmacological treatment.One hundred one medication-naive ADHD children were included. All subjects were administered methylphenidate (MPH)-OROS for 12 weeks. The subjects underwent a computerized comprehensive attention test to measure the response time variability at baseline before MPH treatment and after 12 weeks. Additive regression analyses controlling for ADHD symptom severity, age, sex, IQ, and final dose of MPH examined the association between response time variability on the comprehensive attention test measures and allelic variations in single-nucleotide polymorphisms of the ADRA2A and SLC6A2 before and after MPH treatment.Increasing possession of an A allele at the G1287A polymorphism of SLC6A2 was significantly related to heightened response time variability at baseline in the sustained (P = 2.0 × 10) and auditory selective attention (P = 1.0 × 10) tasks. Response time variability at baseline increased additively with possession of the T allele at the DraI polymorphism of the ADRA2A gene in the auditory selective attention task (P = 2.0 × 10). After medication, increasing possession of a G allele at the MspI polymorphism of the ADRA2A gene was associated with increased MPH-related change in response time variability in the flanker task (P = 1.0 × 10).Our study suggested an association between norepinephrine gene variants and response time variability measured at baseline and after MPH treatment in children with ADHD. Our results add to a growing body of evidence, suggesting that response time variability is a viable endophenotype for ADHD and suggesting its utility as a surrogate end point for measuring stimulant response in pharmacogenetic studies.
42 CFR 493.1256 - Standard: Control procedures.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Systems § 493.1256 Standard: Control procedures. (a) For each test system, the laboratory is responsible... test system failure, adverse environmental conditions, and operator performance. (2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system...
42 CFR 493.1256 - Standard: Control procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Systems § 493.1256 Standard: Control procedures. (a) For each test system, the laboratory is responsible... test system failure, adverse environmental conditions, and operator performance. (2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system...
42 CFR 493.1256 - Standard: Control procedures.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Systems § 493.1256 Standard: Control procedures. (a) For each test system, the laboratory is responsible... test system failure, adverse environmental conditions, and operator performance. (2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system...
42 CFR 493.1256 - Standard: Control procedures.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Systems § 493.1256 Standard: Control procedures. (a) For each test system, the laboratory is responsible... test system failure, adverse environmental conditions, and operator performance. (2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system...
Lauber, M C; Hemsworth, P H; Barnett, J L
2009-11-01
Three experiments examined the impact of breed, time spent with dam (TWD), gender, and late pregnancy induction of parturition and caesarean on the behavioural and heart rate responses of dairy calves at 2 and 6 weeks of age to Open field, Novel object and Startle tests and a Learning task. In Experiment 1 with male Jersey, Friesian and Friesian x Angus calves, there were some significant breed effects on responses to the Open field and the Novel object tests; Jersey calves appeared more curious and less fearful than Friesian x Angus calves. In Experiment 2, in which male and female Friesian calves were removed from their dams either between 0 and 12h or 12 and 24h after birth, there were no significant effects of gender or TWD. In Experiment 3, which studied the effect of induction of parturition using a long-acting glucocorticoid combined with short-acting progesterone 10 days prior to due calving date, there were no significant effects of late pregnancy induction of parturition. Across all three experiments, age at testing was the main factor influencing the responses of the calves. However, a number of interactions suggest that gender, time spent with dam and late pregnancy induction of parturition modified some of the responses to the tests as the calves developed.
Test anxiety and cardiovascular responses to daily academic stressors.
Conley, Kristen M; Lehman, Barbara J
2012-02-01
Routine academic events may cause stress and produce temporary elevations in blood pressure. Students who experience test anxiety may be especially prone to cardiovascular activation in response to academic stress. This study drew on self-reported stress and ambulatory blood pressure measurements provided by 99 undergraduate participants (30% men, mean age=21 years) who participated over 4 days. Posture, activity level, recent consumption and the previous same-day reading were considered as covariates in a series of hierarchical linear models. Results indicate elevations in systolic blood pressure at times of acute academic stressors; neither diastolic blood pressure nor heart rate was linked with academic stress. In addition, those participants higher in test anxiety exhibited especially pronounced elevations in systolic blood pressure during times of acute academic stress. This research suggests that everyday academic stressors are linked with temporary increases in blood pressure and that test anxiety may contribute to these elevations. Test anxiety has implications for future academic and job success, and cardiovascular responses to everyday stress may contribute to health problems later in life. Copyright © 2011 John Wiley & Sons, Ltd.
Keohane, Bernie M; Mason, Steve M; Baguley, David M
2004-02-01
A novel auditory brainstem response (ABR) detection and scoring algorithm, entitled the Vector algorithm is described. An independent clinical evaluation of the algorithm using 464 tests (120 non-stimulated and 344 stimulated tests) on 60 infants, with a mean age of approximately 6.5 weeks, estimated test sensitivity greater than 0.99 and test specificity at 0.87 for one test. Specificity was estimated to be greater than 0.95 for a two stage screen. Test times were of the order of 1.5 minutes per ear for detection of an ABR and 4.5 minutes per ear in the absence of a clear response. The Vector algorithm is commercially available for both automated screening and threshold estimation in hearing screening devices.
Ear swelling test by using laser speckle imaging with a long exposure time
NASA Astrophysics Data System (ADS)
Kalchenko, Vyacheslav; Kuznetsov, Yuri; Preise, Dina; Meglinski, Igor; Harmelin, Alon
2014-06-01
Laser speckle imaging with long exposure time has been applied noninvasively to visualize the immediate reaction of cutaneous vessels in mice in response to a known primary irritant and potential allergen-methyl salicylate. The compound has been used topically on the surface of the pinna and the reaction of the vascular network was examined. We demonstrate that irritant-induced acute vascular reaction can be effectively and accurately detected by laser speckle imaging technique. The current approach holds a great promise for application in routine screening of the cutaneous vascular response induced by contact agents, screenings of mouse ear swelling test, and testing the allergenic potential of new synthetic materials and healthcare pharmaceutical products.
Ahmed, Sameh; Alqurshi, Abdulmalik; Mohamed, Abdel-Maaboud Ismail
2018-07-01
A new robust and reliable high-performance liquid chromatography (HPLC) method with multi-criteria decision making (MCDM) approach was developed to allow simultaneous quantification of atenolol (ATN) and nifedipine (NFD) in content uniformity testing. Felodipine (FLD) was used as an internal standard (I.S.) in this study. A novel marriage between a new interactive response optimizer and a HPLC method was suggested for multiple response optimizations of target responses. An interactive response optimizer was used as a decision and prediction tool for the optimal settings of target responses, according to specified criteria, based on Derringer's desirability. Four independent variables were considered in this study: Acetonitrile%, buffer pH and concentration along with column temperature. Eight responses were optimized: retention times of ATN, NFD, and FLD, resolutions between ATN/NFD and NFD/FLD, and plate numbers for ATN, NFD, and FLD. Multiple regression analysis was applied in order to scan the influences of the most significant variables for the regression models. The experimental design was set to give minimum retention times, maximum resolution and plate numbers. The interactive response optimizer allowed prediction of optimum conditions according to these criteria with a good composite desirability value of 0.98156. The developed method was validated according to the International Conference on Harmonization (ICH) guidelines with the aid of the experimental design. The developed MCDM-HPLC method showed superior robustness and resolution in short analysis time allowing successful simultaneous content uniformity testing of ATN and NFD in marketed capsules. The current work presents an interactive response optimizer as an efficient platform to optimize, predict responses, and validate HPLC methodology with tolerable design space for assay in quality control laboratories. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Gloss, B. B.
1980-01-01
In order to aid in the design of the National Transonic Facility (NTF) control system, test section/plenum response studies were carried out in a 0.186 scale model of the NTF high speed duct. Two types of disturbances, those induced by the model and those induced by the compressor inlet guide vanes were simulated. Some observations with regard to the test section/plenum response tests are summarized as follows. A resonance frequency for the test section/plenum area of the tunnel of approximately 50 Hz was observed for Mach numbers from 0.40 to 0.90. However, since the plenum is 3.1 times (based on volume) too large for the scaled size of the test section, care must be taken in extrapolating these data to NTF conditions. The plenum pressure data indicate the existence of pressure gradients in the plenum. The test results indicate that the difference between test section static pressure and plenum pressure is dependent on test section flow conditions. Plenum response to inlet guide vane type disturbances appears to be slower than plenum response to test section disturbances.
Advanced structural analysis of nanoporous materials by thermal response measurements.
Oschatz, Martin; Leistner, Matthias; Nickel, Winfried; Kaskel, Stefan
2015-04-07
Thermal response measurements based on optical adsorption calorimetry are presented as a versatile tool for the time-saving and profound characterization of the pore structure of porous carbon-based materials. This technique measures the time-resolved temperature change of an adsorbent during adsorption of a test gas. Six carbide and carbon materials with well-defined nanopore architecture including micro- and/or mesopores are characterized by thermal response measurements based on n-butane and carbon dioxide as the test gases. With this tool, the pore systems of the model materials can be clearly distinguished and accurately analyzed. The obtained calorimetric data are correlated with the adsorption/desorption isotherms of the materials. The pore structures can be estimated from a single experiment due to different adsorption enthalpies/temperature increases in micro- and mesopores. Adsorption/desorption cycling of n-butane at 298 K/1 bar with increasing desorption time allows to determine the pore structure of the materials in more detail due to different equilibration times. Adsorption of the organic test gas at selected relative pressures reveals specific contributions of particular pore systems to the increase of the temperature of the samples and different adsorption mechanisms. The use of carbon dioxide as the test gas at 298 K/1 bar provides detailed insights into the ultramicropore structure of the materials because under these conditions the adsorption of this test gas is very sensitive to the presence of pores smaller than 0.7 nm.
Psihogios, Alexandra M; Murray, Caitlin; Zebracki, Kathy; Acevedo, Laura; Holmbeck, Grayson N
2017-10-01
The present longitudinal, multi-method, and multi-informant study examined biological, neuropsychological, and social predictors of medical adherence and responsibility among early adolescents with spina bifida (SB). Youth with SB (M age = 11.40 at Time 1) and their parents and teachers completed surveys, and families and peers completed observational assessments, at two biennial data collection time points (n = 112 for both time points). Multinomial logistic regressions tested predictors of group membership (adherent vs. nonadherent and child responsible vs. not responsible with SB medical tasks). Consistent with the bio-neuropsychosocial model, several risk factors emerged for SB management. Impaired gross motor classification and low IQ were barriers to obtaining medical responsibility, and high family stress and executive dysfunction were barriers to adherence and responsibility. This study offered intervention targets to promote self-management and adherence for youth with SB and their families, including parent stress-management and family problem-solving. © The Author 2016. Published by Oxford University Press on behalf of the Society of Pediatric Psychology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Artieda, J; Valencia, M; Alegre, M; Olaziregi, O; Urrestarazu, E; Iriarte, J
2004-03-01
Steady-state potentials are oscillatory responses generated by a rhythmic stimulation of a sensory pathway. The frequency of the response, which follows the frequency of stimulation, is maximal at a stimulus rate of 40 Hz for auditory stimuli. The exact cause of these maximal responses is not known, although some authors have suggested that they might be related to the 'working frequency' of the auditory cortex. Testing of the responses to different frequencies of stimulation may be lengthy if a single frequency is studied at a time. Our aim was to develop a fast technique to explore the oscillatory response to auditory stimuli, using a tone modulated in amplitude by a sinusoid whose frequency increases linearly in frequency ('chirp') from 1 to 120 Hz. Time-frequency transforms were used for the analysis of the evoked responses in 10 subjects. Also, we analyzed whether the peaks in these responses were due to increases of amplitude or to phase-locking phenomena, using single-sweep time-frequency transforms and inter-trial phase analysis. The pattern observed in the time-frequency transform of the chirp-evoked potential was very similar in all subjects: a diagonal band of energy was observed, corresponding to the frequency of modulation at each time instant. Two components were present in the band, one around 45 Hz (30-60 Hz) and a smaller one between 80 and 120 Hz. Inter-trial phase analysis showed that these components were mainly due to phase locking phenomena. A simultaneous testing of the amplitude-modulation-following oscillatory responses to auditory stimulation is feasible using a tone modulated in amplitude at increasing frequencies. The maximal energies found at stimulation frequencies around 40 Hz are probably due to increased phase-locking of the individual responses.
DART: A Microcomputer Program for Response Latency Analysis.
ERIC Educational Resources Information Center
Greene, John O.; Greene, Barry F.
1987-01-01
Discusses how chronometric measures such as the DART (Display And Response Timing) computer program, have become virtually indispensable in testing cognitive theories of human social behavior. Describes how the DART (1) provides a way to collect response latency data; and (2) allows measurement of response latencies to a set of user-specified,…
Acquisition and Retention of Esperanto: The Case for Error Correction and Immediate Feedback
ERIC Educational Resources Information Center
Brosvic, Gary M.; Epstein, Michael L.; Dihoff, Roberta E.; Cook, Michael J.
2006-01-01
Participants completed 5 laboratory examinations during which the number of responses permitted (1 response, up to 4 responses) and the timing of feedback (no feedback control: Scantron form; delayed feedback: end-of-test, 24-hr delay; immediate feedback: assistant, response form) were manipulated. Participants completed a 100-item cumulative…
Real-Time Frequency Response Estimation Using Joined-Wing SensorCraft Aeroelastic Wind-Tunnel Data
NASA Technical Reports Server (NTRS)
Grauer, Jared A; Heeg, Jennifer; Morelli, Eugene A
2012-01-01
A new method is presented for estimating frequency responses and their uncertainties from wind-tunnel data in real time. The method uses orthogonal phase-optimized multi- sine excitation inputs and a recursive Fourier transform with a least-squares estimator. The method was first demonstrated with an F-16 nonlinear flight simulation and results showed that accurate short period frequency responses were obtained within 10 seconds. The method was then applied to wind-tunnel data from a previous aeroelastic test of the Joined- Wing SensorCraft. Frequency responses describing bending strains from simultaneous control surface excitations were estimated in a time-efficient manner.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Wenzhong; Wang, Xiao; Muljadi, Eduard
With increasing penetrations of wind power on electric grids, the stability and reliability of interconnected power systems may be impacted. In some countries that have developed renewable energy sources and systems, grid codes have been revised to require wind power plants (WPPs) to provide ancillary services to support the power system frequency in case of severe grid events. To do this, wind turbine generators (WTGs) should be deloaded to reserve a certain amount of active power for primary frequency response; however, deloading curtails annual energy production, and the market for this type of service needs to be further developed. Inmore » this report, we focus on the temporary frequency support provided by WTGs through inertial response. WTGs have potential to provide inertial response, but appropriate control methods should be implemented. With the implemented inertial control methods, wind turbines are capable of increasing their active power output by releasing some of their stored kinetic energy when a frequency excursion occurs. Active power can be temporarily boosted above the maximum power points, after which the rotor speed decelerates, and subsequently an active power output reduction restores the kinetic energy. In this report, we develop two types of models for wind power systems: the first is common, based on the wind power aerodynamic equation, and the power coefficient can be regressed using nonlinear functions; the second is much more complicated, wherein the wind turbine system is modeled using the Fatigue, Aerodynamics, Structures, and Turbulence Modeling (FAST) tool with several degrees of freedoms. A nine-bus test power system is built in Simulink and the Real-Time Digital Simulator, respectively, which are used to evaluate the frequency support performance of the WPPs. We implement two distinct types of inertial control methods in the modeled wind turbines: frequency-based inertial control (FBIC) and stepwise inertial control (SIC). We compare the performances of the two methods in terms of their frequency nadirs, rates of change of frequency, and recovery times. We conclude the results under various wind speeds and penetration cases, which provide insight into designing the inertial response of WTGs. Further, we discuss the impact of the parameters on the performance of the inertial control methods. We evaluate both the scaling factors for the FBIC method and the slope values for the TLIC methods. The simulation work shows the characteristics of different inertial responses compared to conventional synchronous generators. Based on the simulation results, we modify, improve, and test the inertial control methods under a more realistic wind turbine model based on FAST. We then validate the inertial responses under highly turbulent wind conditions generated by TurbSim, and we examine their influences on the turbine mechanical components. The extensive simulation proves the effectiveness of the proposed inertial control methods as well as the nine-bus test power system. We then reconsider the parameters. We rebuild the same test power system using Real time Simulator Computer Aided Design (RSCAD), and we implement the inertial control methods in the real Controls Advanced Research Turbine (CART3), which is prepared for the hardware-in-the-loop field-test simulation. After the setups for the hardware and software hybrid simulation platform are complete, the inertial response is further tested on a real wind turbine for the first time, in which CART3 release the controlled inertial response against the emulated frequency excursion, provided by the real-time simulated power system test bed in RTDS.« less
Rocco, Isadora Salvador; Viceconte, Marcela; Pauletti, Hayanne Osiro; Matos-Garcia, Bruna Caroline; Marcondi, Natasha Oliveira; Bublitz, Caroline; Bolzan, Douglas William; Moreira, Rita Simone Lopes; Reis, Michel Silva; Hossne, Nelson Américo; Gomes, Walter José; Arena, Ross; Guizilini, Solange
2017-12-26
We aimed to investigate the ability of oxygen uptake kinetics to predict short-term outcomes after off-pump coronary artery bypass grafting. Fifty-two patients aged 60.9 ± 7.8 years waiting for off-pump coronary artery bypass surgery were evaluated. The 6-min walk test distance was performed pre-operatively, while simultaneously using a portable cardiopulmonary testing device. The transition of oxygen uptake kinetics from rest to exercise was recorded to calculate oxygen uptake kinetics fitting a monoexponential regression model. Oxygen uptake at steady state, constant time, and mean response time corrected by work rate were analysed. Short-term clinical outcomes were evaluated during the early post-operative of off-pump coronary artery bypass surgery. Multivariate analysis showed body mass index, surgery time, and mean response time corrected by work rate as independent predictors for short-term outcomes. The optimal mean response time corrected by work rate cut-off to estimate short-term clinical outcomes was 1.51 × 10 -3 min 2 /ml. Patients with slower mean response time corrected by work rate demonstrated higher rates of hypertension, diabetes, EuroSCOREII, left ventricular dysfunction, and impaired 6-min walk test parameters. The per cent-predicted distance threshold of 66% in the pre-operative was associated with delayed oxygen uptake kinetics. Pre-operative oxygen uptake kinetics during 6-min walk test predicts short-term clinical outcomes after off-pump coronary artery bypass surgery. From a clinically applicable perspective, a threshold of 66% of pre-operative predicted 6-min walk test distance indicated slower kinetics, which leads to longer intensive care unit and post-surgery hospital length of stay. Implications for rehabilitation Coronary artery bypass grafting is a treatment aimed to improve expectancy of life and prevent disability due to the disease progression; The use of pre-operative submaximal functional capacity test enabled the identification of patients with high risk of complications, where patients with delayed oxygen uptake kinetics exhibited worse short-term outcomes; Our findings suggest the importance of the rehabilitation in the pre-operative in order to "pre-habilitate" the patients to the surgical procedure; Faster oxygen uptake on-kinetics could be achieved by improving the oxidative capacity of muscles and cardiovascular conditioning through rehabilitation, adding better results following cardiac surgery.
Rapid Generation and Testing of a Lassa Fever Vaccine Using VaxCelerate Platform
2014-08-28
essentially the same way each time but is capable to producing effective vaccine responses to a range of pathogens, and to do this without the use of...this distributed vaccine development consortium to rapidly produce and test a novel vaccine of relevance to public health responses. In parallel...with this effort, the consortium produced and tested a modified version of its self-assembling vaccine protein that used a subunit of the full
Modeling Pacing Behavior and Test Speededness Using Latent Growth Curve Models
ERIC Educational Resources Information Center
Kahraman, Nilufer; Cuddy, Monica M.; Clauser, Brian E.
2013-01-01
This research explores the usefulness of latent growth curve modeling in the study of pacing behavior and test speededness. Examinee response times from a high-stakes, computerized examination, collected before and after the examination was subjected to a timing change, were analyzed using a series of latent growth curve models to detect…
Evaluation of near-critical overdamping effects in slug-test response
Weeks, Edwin P.; Clark, Arthur C.
2013-01-01
A slug test behaves as a harmonic oscillator, subject to both inertial effects and viscous damping. When viscous and inertial forces are closely balanced, the system is nearly critically damped, and water-level recovery is affected by inertial effects, but does not exhibit oscillation. These effects were investigated by use of type curves, generated both by modification of Kipp's (1985) computer program and by use of the Butler-Zhan (2004) model. Utility of the type curves was verified by re-analysis of the Regina slug test previously analyzed by Kipp. These type curves indicate that near-critical inertial effects result in early-time delayed water-level response followed by merger with, or more rapid recovery than, response for the fully damped case. Because of this early time response, slug tests in the moderately over-damped range are best analyzed using log-log type curves of (1 − H/H0) vs. Tt/. Failure to recognize inertial effects in slug test data could result in an over-estimate of transmissivity, and a too-small estimate of storage coefficient or too-large estimate of well skin. However, application of the widely used but highly empirical Hvorslev (1951) method to analyze both the Regina slug test and type-curve generated data indicate that such analyses provide T values within a factor of 2 of the true value.
Nour, Svetlana; LaRosa, Jerry; Inn, Kenneth G W
2011-08-01
The present challenge for the international emergency radiobioassay community is to analyze contaminated samples rapidly while maintaining high quality results. The National Institute of Standards and Technology (NIST) runs a radiobioassay measurement traceability testing program to evaluate the radioanalytical capabilities of participating laboratories. The NIST Radiochemistry Intercomparison Program (NRIP) started more than 10 years ago, and emergency performance testing was added to the program seven years ago. Radiobioassay turnaround times under the NRIP program for routine production and under emergency response scenarios are 60 d and 8 h, respectively. Because measurement accuracy and sample turnaround time are very critical in a radiological emergency, response laboratories' analytical systems are best evaluated and improved through traceable Performance Testing (PT) programs. The NRIP provides participant laboratories with metrology tools to evaluate their performance and to improve it. The program motivates the laboratories to optimize their methodologies and minimize the turnaround time of their results. Likewise, NIST has to make adjustments and periodical changes in the bioassay test samples in order to challenge the participating laboratories continually. With practice, radioanalytical measurements turnaround time can be reduced to 3-4 h.
NASA Technical Reports Server (NTRS)
Bragg-Sitton, Shannon M.; Dickens, Ricky; Dixon, David; Kapernick, Richard
2007-01-01
Non-nuclear testing can be a valuable tool in the development of a space nuclear power system, providing system characterization data and allowing one to work through various fabrication, assembly and integration issues without the cost and time associated with a full ground nuclear test. In a non-nuclear test bed, electric heaters are used to simulate the heat from nuclear fuel. Testing with non-optimized heater elements allows one to assess thermal, heat transfer. and stress related attributes of a given system, but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. High fidelity thermal simulators that match both the static and the dynamic fuel pin performance that would be observed in an operating, fueled nuclear reactor can vastly increase the value of non-nuclear test results. With optimized simulators, the integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and fueled nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response characteristics and assess potential design improvements at relatively small fiscal investment. Initial conceptual thermal simulator designs are determined by simple one-dimensional analysis at a single axial location and at steady state conditions; feasible concepts are then input into a detailed three-dimensional model for comparison to expected fuel pin performance. Static and dynamic fuel pin performance for a proposed reactor design is determined using SINDA/FLUINT thermal analysis software, and comparison is made between the expected nuclear performance and the performance of conceptual thermal simulator designs. Through a series of iterative analyses, a conceptual high fidelity design is developed: this is followed by engineering design, fabrication, and testing to validate the overall design process. Test results presented in this paper correspond to a "first cut" simulator design for a potential liquid metal (NaK) cooled reactor design that could be applied for Lunar surface power. Proposed refinements to this simulator design are also presented.
ERIC Educational Resources Information Center
Kehoe, E. James; Ludvig, Elliot A.; Sutton, Richard S.
2014-01-01
The present experiment tested whether or not the time course of a conditioned eyeblink response, particularly its duration, would expand and contract, as the magnitude of the conditioned response (CR) changed massively during acquisition, extinction, and reacquisition. The CR duration remained largely constant throughout the experiment, while CR…
ERIC Educational Resources Information Center
Fific, Mario; Little, Daniel R.; Nosofsky, Robert M.
2010-01-01
We formalize and provide tests of a set of logical-rule models for predicting perceptual classification response times (RTs) and choice probabilities. The models are developed by synthesizing mental-architecture, random-walk, and decision-bound approaches. According to the models, people make independent decisions about the locations of stimuli…
NASA Technical Reports Server (NTRS)
Pierson, Duane L.; Mehta, Satish K.; Cooley, Helen; Dubow, Robin; Lugg, Desmond
1999-01-01
Reactivation of Epstein-Barr virus (EBV) and cell-mediated immune (CMI) responses were followed in 16 Antarctic expeditioners during winter-over isolation at two Australian National Antarctic Research Expedition stations. Delayed-type hypersensitivity skin testing was used as an indicator of the CMI response, which was evaluated two times before winter isolation and three times during isolation. At all five evaluation times, 8 or more of the 16 subjects had a diminished. CMI response. Diminished CMI was observed on every test occasion in 4/16 subjects; only 2/16 subjects exhibited normal CMI responses for all five tests. A polymerase chain reaction (PCR) assay was used to detect EBV DNA in saliva specimens collected before, after, and during the winter isolation. EBV DNA was present in 17% (111/642) of the saliva specimens; all 16 subjects shed EBV in their saliva on at least one occasion. The probability of EBV shedding increased (p=0.013) from 6% before or after winter isolation to 13% during the winter period. EBV appeared in saliva during the winter isolation more frequently (p<0.0005) when CMI responsiveness was diminished than when CMI status was normal. The findings indicate that the psychosocial, physical, and other stresses associated with working and living in physical isolation during the Antarctic winter results in diminished CMI and an accompanying increased reactivation and shedding of latent viruses.
NASA Technical Reports Server (NTRS)
Mehta, S. K.; Pierson, D. L.; Cooley, H.; Dubow, R.; Lugg, D.
2000-01-01
Epstein-Barr virus (EBV) reactivation and cell-mediated immune (CMI) responses were followed in 16 Antarctic expeditioners during winter-over isolation at 2 Australian National Antarctic Research Expedition stations. Delayed-type hypersensitivity (DTH) skin testing was used as an indicator of the CMI response, that was evaluated 2 times before winter isolation and 3 times during isolation. At all 5 evaluation times, 8 or more of the 16 subjects had a diminished CMI response. Diminished DTH was observed on every test occasion in 4/16 subjects; only 2/16 subjects exhibited normal DTH responses for all 5 tests. A polymerase chain reaction (PCR) assay was used to detect EBV DNA in saliva specimens collected before, during, and after the winter isolation. EBV DNA was present in 17% (111/642) of the saliva specimens; all 16 subjects shed EBV in their saliva on at least 1 occasion. The probability of EBV shedding increased (P = 0.013) from 6% before or after winter isolation to 13% during the winter period. EBV appeared in saliva during the winter isolation more frequently (P < 0.0005) when DTH response was diminished than when DTH was normal. The findings indicate that the psychosocial, physical, and other stresses associated with working and living in physical isolation during the Antarctic winter result in diminished CMI and an accompanying increased reactivation and shedding of latent viruses.
Health responsibility and workplace health promotion among women: early detection of cancer.
Kushnir, T; Rabinowitz, S; Melamed, S; Weisberg, E; Ribak, J
1995-01-01
The importance of health responsibility as one aspect of a health-promoting lifestyle has been emphasized repeatedly. Yet there are only a few empirical studies of its role in preventive behavior. We examined the relationship between health responsibility and early-detection practices for breast and cervical cancer. A group of 253 women employees of a large industrial company participated in a cancer screening program subsidized by the employer. They completed questionnaires assessing health responsibility and reported early-detection practices: frequency of breast self-examination and physician breast examinations, frequency of Pap tests, and time lapsed since last Pap test and breast examinations. Health responsibility was a significant independent predictor of breast examination indicators but not of Pap tests. Education level was an important predictor for Pap tests, and age predicted most early-detection practices. The findings lend some support to the role of health responsibility in initiating breast examinations. Better prediction of early-detection practices could be achieved by adding cognitive and emotional components to the existing responsibility scale and by distinguishing between retrospective and prospective responsibility.
Coiro, Vittorio; Volpi, Riccardo; Casti, Amos; Maffei, Maria Ludovica; Stella, Adriano; Volta, Elio; Chiodera, Paolo
2011-06-01
• Alprazolam (ALP), a benzodiazepine activating GABAergic receptors, is involved in ACTH secretion. • This study demonstrates a partial opioid influence in the inhibitory effect of ALP on the release of ACTH/cortisol during physical exercise. To establish the possible involvement of alprazolam (ALP) and/or opiates in the mechanism underlying the ACTH/cortisol response to physical exercise. Tests were carried out under basal conditions (exercise control test), exercise plus ALP (50 µg at time -90 min), naloxone (10 mg at time 0) or ALP plus naloxone. Plasma ACTH and serum cortisol concentrations were evaluated in blood samples taken before, during and after the bicycle ergometer tests. ACTH and cortisol concentrations rose significantly after physical exercise. Maximum peak at time 15 min (P ≤ 0.01 vs. baseline) for ACTH and at time 30 min (P ≤ 0.01 vs. baseline) for cortisol. In the presence of naloxone, the ACTH and cortisol responses were significantly increased (maximum peak at time 20 min, P ≤ 0.02 vs. control test for ACTH, and at time 30 min (P ≤ 0.01 vs. baseline) for cortisol) whereas they were abolished by ALP. When ALP and naloxone were given together, the inhibitory effect of ALP was partial. These data demonstrate an inhibitory effect of ALP in the regulation of the ACTH/cortisol response to physical exercise in man and suggest that GABAergic receptor activating benzodiazepines and opioids interact in the neuroendocrine secretion of ACTH/cortisol. © 2011 The Authors. British Journal of Clinical Pharmacology © 2011 The British Pharmacological Society.
NASA Astrophysics Data System (ADS)
Morgenthaler, George W.; Nuñez, German R.; Botello, Aaron M.; Soto, Jose; Shrairman, Ruth; Landau, Alexander
1998-01-01
Many reaction time experiments have been conducted over the years to observe human responses. However, most of the experiments that were performed did not have quantitatively accurate instruments for measuring change in reaction time under stress. There is a great need for quantitative instruments to measure neuromuscular reaction responses under stressful conditions such as distraction, disorientation, disease, alcohol, drugs, etc. The two instruments used in the experiments reported in this paper are such devices. Their accuracy, portability, ease of use, and biometric character are what makes them very special. PACE™ is a software model used to measure reaction time. VeriFax's Impairoscope measures the deterioration of neuromuscular responses. During the 1997 Summer Semester, various reaction time experiments were conducted on University of Colorado faculty, staff, and students using the PACE™ system. The tests included both two-eye and one-eye unstressed trials and trials with various stresses such as fatigue, distractions in which subjects were asked to perform simple arithmetic during the PACE™ tests, and stress due to rotating-chair dizziness. Various VeriFax Impairoscope tests, both stressed and unstressed, were conducted to determine the Impairoscope's ability to quantitatively measure this impairment. In the 1997 Fall Semester, a Phase II effort was undertaken to increase test sample sizes in order to provide statistical precision and stability. More sophisticated statistical methods remain to be applied to better interpret the data.
Dynamic Response Testing in an Electrically Heated Reactor Test Facility
NASA Astrophysics Data System (ADS)
Bragg-Sitton, Shannon M.; Morton, T. J.
2006-01-01
Non-nuclear testing can be a valuable tool in the development of a space nuclear power or propulsion system. In a non-nuclear test bed, electric heaters are used to simulate the heat from nuclear fuel. Standard testing allows one to fully assess thermal, heat transfer, and stress related attributes of a given system, but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. The integration of thermal hydraulic hardware tests with simulated neutronic response provides a bridge between electrically heated testing and fueled nuclear testing. By implementing a neutronic response model to simulate the dynamic response that would be expected in a fueled reactor system, one can better understand system integration issues, characterize integrated system response times and response characteristics, and assess potential design improvements at a relatively small fiscal investment. Initial system dynamic response testing was demonstrated on the integrated SAFE-100a heat pipe (HP) cooled, electrically heated reactor and heat exchanger hardware, utilizing a one-group solution to the point kinetics equations to simulate the expected neutronic response of the system. Reactivity feedback calculations were then based on a bulk reactivity feedback coefficient and measured average core temperature. This paper presents preliminary results from similar dynamic testing of a direct drive gas cooled reactor system (DDG), demonstrating the applicability of the testing methodology to any reactor type and demonstrating the variation in system response characteristics in different reactor concepts. Although the HP and DDG designs both utilize a fast spectrum reactor, the method of cooling the reactor differs significantly, leading to a variable system response that can be demonstrated and assessed in a non-nuclear test facility. Planned system upgrades to allow implementation of higher fidelity dynamic testing are also discussed. Proposed DDG testing will utilize a higher fidelity point kinetics model to control core power transients, and reactivity feedback will be based on localized feedback coefficients and several independent temperature measurements taken within the core block. This paper presents preliminary test results and discusses the methodology that will be implemented in follow-on DDG testing and the additional instrumentation required to implement high fidelity dynamic testing.
Code of Federal Regulations, 2010 CFR
2010-04-01
... missed. If the merit pay increase that the employee missed during service is based on a skills test or... reemployment position and then give him or her the skills test or examination. No fixed amount of time for... typical time necessary to prepare or study for the test, the duties and responsibilities of the...
10 CFR 50.59 - Changes, tests, and experiments.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 1 2012-01-01 2012-01-01 false Changes, tests, and experiments. 50.59 Section 50.59..., Limitations, and Conditions of Licenses and Construction Permits § 50.59 Changes, tests, and experiments. (a... operator actions and response times). (6) Tests or experiments not described in the final safety analysis...
10 CFR 50.59 - Changes, tests, and experiments.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 1 2013-01-01 2013-01-01 false Changes, tests, and experiments. 50.59 Section 50.59..., Limitations, and Conditions of Licenses and Construction Permits § 50.59 Changes, tests, and experiments. (a... operator actions and response times). (6) Tests or experiments not described in the final safety analysis...
10 CFR 50.59 - Changes, tests, and experiments.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 1 2014-01-01 2014-01-01 false Changes, tests, and experiments. 50.59 Section 50.59..., Limitations, and Conditions of Licenses and Construction Permits § 50.59 Changes, tests, and experiments. (a... operator actions and response times). (6) Tests or experiments not described in the final safety analysis...
Frýbort, Pavel; Kokštejn, Jakub; Musálek, Martin; Süss, Vladimír
2016-01-01
A soccer player’s capability to control and manage his behaviour in a game situation is a prerequisite, reflecting not only swift and accurate tactical decision-making, but also prompt implementation of a motor task during intermittent exercise conditions. The purpose of this study was to analyse the relationship between varying exercise intensity and the visual-motor response time and the accuracy of motor response in an offensive game situation in soccer. The participants (n = 42) were male, semi-professional, soccer players (M age 18.0 ± 0.9 years) and trained five times a week. Each player performed four different modes of exercise intensity on the treadmill (motor inactivity, aerobic, intermittent and anaerobic activity). After the end of each exercise, visual-motor response time and accuracy of motor response were assessed. Players’ motion was captured by digital video camera. ANOVA indicated no significant difference (p = 0.090) in the accuracy of motor response between the four exercise intensity modes. Practical significance (Z-test = 0.31) was found in visual-motor response time between exercise with dominant involvement of aerobic metabolism, and intense intermittent exercise. A medium size effect (Z-test = 0.34) was also found in visual-motor response time between exercise with dominant involvement of aerobic metabolism and exercise with dominant involvement of anaerobic metabolism, which was confirmed by ANOVA (897.02 ± 57.46 vs. 940.95 ± 71.14; p = 0.002). The results showed that different modes of exercise intensity do not adversely affect the accuracy of motor responses; however, high-intensity exercise has a negative effect on visual-motor response time in comparison to moderate intensity exercise. Key points Different exercise intensity modes did not affect the accuracy of motor response. Anaerobic, highly intensive short-term exercise significantly decreased the visual-motor response time in comparison with aerobic exercise. Further research should focus on the assessment of VMRT from a player’s real - field position view rather than a perspective view. PMID:27274671
NASA Astrophysics Data System (ADS)
Hwang, James Ho-Jin; Duran, Adam
2016-08-01
Most of the times pyrotechnic shock design and test requirements for space systems are provided in Shock Response Spectrum (SRS) without the input time history. Since the SRS does not describe the input or the environment, a decomposition method is used to obtain the source time history. The main objective of this paper is to develop a decomposition method producing input time histories that can satisfy the SRS requirement based on the pyrotechnic shock test data measured from a mechanical impact test apparatus. At the heart of this decomposition method is the statistical representation of the pyrotechnic shock test data measured from the MIT Lincoln Laboratory (LL) designed Universal Pyrotechnic Shock Simulator (UPSS). Each pyrotechnic shock test data measured at the interface of a test unit has been analyzed to produce the temporal peak acceleration, Root Mean Square (RMS) acceleration, and the phase lag at each band center frequency. Maximum SRS of each filtered time history has been calculated to produce a relationship between the input and the response. Two new definitions are proposed as a result. The Peak Ratio (PR) is defined as the ratio between the maximum SRS and the temporal peak acceleration at each band center frequency. The ratio between the maximum SRS and the RMS acceleration is defined as the Energy Ratio (ER) at each band center frequency. Phase lag is estimated based on the time delay between the temporal peak acceleration at each band center frequency and the peak acceleration at the lowest band center frequency. This stochastic process has been applied to more than one hundred pyrotechnic shock test data to produce probabilistic definitions of the PR, ER, and the phase lag. The SRS is decomposed at each band center frequency using damped sinusoids with the PR and the decays obtained by matching the ER of the damped sinusoids to the ER of the test data. The final step in this stochastic SRS decomposition process is the Monte Carlo (MC) simulation. The MC simulation identifies combinations of the PR and decays that can meet the SRS requirement at each band center frequency. Decomposed input time histories are produced by summing the converged damped sinusoids with the MC simulation of the phase lag distribution.
Gravitropic responses of the Avena coleoptile in space and on clinostats. II. Is reciprocity valid?
NASA Technical Reports Server (NTRS)
Johnsson, A.; Brown, A. H.; Chapman, D. K.; Heathcote, D.; Karlsson, C.
1995-01-01
Experiments were undertaken to determine if the reciprocity rule is valid for gravitropic responses of oat coleoptiles in the acceleration region below 1 g. The rule predicts that the gravitropic response should be proportional to the product of the applied acceleration and the stimulation time. Seedlings were cultivated on 1 g centrifuges and transferred to test centrifuges to apply a transverse g-stimulation. Since responses occurred in microgravity, the uncertainties about the validity of clinostat simulation of weightlessness was avoided. Plants at two stages of coleoptile development were tested. Plant responses were obtained using time-lapse video recordings that were analyzed after the flight. Stimulus intensities and durations were varied and ranged from 0.1 to 1.0 g and from 2 to 130 min, respectively. For threshold g-doses the reciprocity rule was obeyed. The threshold dose was of the order of 55 g s and 120 g s, respectively, for two groups of plants investigated. Reciprocity was studied also at bending responses which are from just above the detectable level to about 10 degrees. The validity of the rule could not be confirmed for higher g-doses, chiefly because the data were more variable. It was investigated whether the uniformity of the overall response data increased when the gravitropic dose was defined as (gm x t) with m-values different from unity. This was not the case and the reciprocity concept is, therefore, valid also in the hypogravity region. The concept of gravitropic dose, the product of the transverse acceleration and the stimulation time, is also well-defined in the acceleration region studied. With the same hardware, tests were done on earth where responses occurred on clinostats. The results did not contradict the reciprocity rule but scatter in the data was large.
Son, Byungjik; Jeon, Seunggon
2018-01-01
A disaster preventive structural health monitoring (SHM) system needs to be equipped with the following abilities: First, it should be able to simultaneously measure diverse types of data (e.g., displacement, velocity, acceleration, strain, load, temperature, humidity, etc.) for accurate diagnosis. Second, it also requires standalone power supply to guarantee its immediate response in crisis (e.g., sudden interruption of normal AC power in disaster situations). Furthermore, it should be capable of prompt processing and realtime wireless communication of a huge amount of data. Therefore, this study is aimed at developing a wireless unified-maintenance system (WUMS) that would satisfy all the requirements for a disaster preventive SHM system of civil structures. The WUMS is designed to measure diverse types of structural responses in realtime based on wireless communication, allowing users to selectively use WiFi RF band and finally working in standalone mode by means of the field-programmable gate array (FPGA) technology. To verify its performance, the following tests were performed: (i) A test to see how far communication is possible in open field, (ii) a test on a shaker to see how accurate responses are, (iii) a modal test on a bridge to see how exactly characteristic real-time dynamic responses are of structures. The test results proved that the WUMS was able to secure stable communication far up to nearly 800 m away by acquiring wireless responses in realtime accurately, when compared to the displacement and acceleration responses which were acquired through wired communication. The analysis of dynamic characteristics also showed that the wireless acceleration responses in real-time represented satisfactorily the dynamic properties of structures. Therefore, the WUMS is proved valid as a SHM, and its outstanding performance is also proven. PMID:29747403
Heo, Gwanghee; Son, Byungjik; Kim, Chunggil; Jeon, Seunggon; Jeon, Joonryong
2018-05-09
A disaster preventive structural health monitoring (SHM) system needs to be equipped with the following abilities: First, it should be able to simultaneously measure diverse types of data (e.g., displacement, velocity, acceleration, strain, load, temperature, humidity, etc.) for accurate diagnosis. Second, it also requires standalone power supply to guarantee its immediate response in crisis (e.g., sudden interruption of normal AC power in disaster situations). Furthermore, it should be capable of prompt processing and realtime wireless communication of a huge amount of data. Therefore, this study is aimed at developing a wireless unified-maintenance system (WUMS) that would satisfy all the requirements for a disaster preventive SHM system of civil structures. The WUMS is designed to measure diverse types of structural responses in realtime based on wireless communication, allowing users to selectively use WiFi RF band and finally working in standalone mode by means of the field-programmable gate array (FPGA) technology. To verify its performance, the following tests were performed: (i) A test to see how far communication is possible in open field, (ii) a test on a shaker to see how accurate responses are, (iii) a modal test on a bridge to see how exactly characteristic real-time dynamic responses are of structures. The test results proved that the WUMS was able to secure stable communication far up to nearly 800 m away by acquiring wireless responses in realtime accurately, when compared to the displacement and acceleration responses which were acquired through wired communication. The analysis of dynamic characteristics also showed that the wireless acceleration responses in real-time represented satisfactorily the dynamic properties of structures. Therefore, the WUMS is proved valid as a SHM, and its outstanding performance is also proven.
Characterization of multi-dye pressure-sensitive microbeads
NASA Astrophysics Data System (ADS)
Lacroix, Daniel; Viraye-Chevalier, Teddy; Seiter, Guillaume; Howard, Jonathan; Dabiri, Dana; Khalil, Gamal E.; Xia, Younan; Zhu, Cun
2013-11-01
The response times of pressure-sensitive particles to passing shockwaves were measured to investigate their ability to accurately determine pressure changes in unsteady flows. The particles tested were loaded with novel pressure-sensitive dyes such as Pt (II) meso-tetra(pentafluorophenyl)porphine, Pt(II) octaethylporphine, bis(3,5-difluoro-2-(2-pyridyl)phenyl-(2-carboxypyridyl))iridium III, and iridium(III) bis(4-phenylthieno[3,2-c] pyridinato-N,C2')acetylacetonate. For this work, porous silicon dioxide pressure-sensitive beads (PSBeads) were used. Two synthetic procedures were used to fabricate the particles. In the first, a one-step method loaded dyes during the synthesis of microbeads, in the second a two-step method synthesized the microbeads first, then loaded the dyes. The shock tube facility was used to measure the response times of microbeads to fast pressure jumps. The study involved testing multiple luminophors loaded in microbeads with various size distributions. Response times for the silica-based microbeads ranged between 26 μs and 462 μs (at 90% of the amplitude response), which are much faster than previously reported polystyrene-based microbead response times, which range from 507 μs to 1582 μs (at 90% of the amplitude response) [F. Kimura, M. Rodriguez, J. McCann, B. Carlson, D. Dabiri, G. Khalil, J. B. Callis, Y. Xia, and M. Gouterman, "Development and characterization of fast responding pressure sensitive microspheres," Rev. Sci. Instrum. 79, 074102 (2008)].
Richardson-Klavehn, A; Gardiner, J M
1998-05-01
Depth-of-processing effects on incidental perceptual memory tests could reflect (a) contamination by voluntary retrieval, (b) sensitivity of involuntary retrieval to prior conceptual processing, or (c) a deficit in lexical processing during graphemic study tasks that affects involuntary retrieval. The authors devised an extension of incidental test methodology--making conjunctive predictions about response times as well as response proportions--to discriminate among these alternatives. They used graphemic, phonemic, and semantic study tasks, and a word-stem completion test with incidental, intentional, and inclusion instructions. Semantic study processing was superior to phonemic study processing in the intentional and inclusion tests, but semantic and phonemic study processing produced equal priming in the incidental test, showing that priming was uncontaminated by voluntary retrieval--a conclusion reinforced by the response-time data--and that priming was insensitive to prior conceptual processing. The incidental test nevertheless showed a priming deficit following graphemic study processing, supporting the lexical-processing hypothesis. Adding a lexical decision to the 3 study tasks eliminated the priming deficit following graphemic study processing, but did not influence priming following phonemic and semantic processing. The results provide the first clear evidence that depth-of-processing effects on perceptual priming can reflect lexical processes, rather than voluntary contamination or conceptual processes.
Zhao, Ziyan; Henowitz, Liza; Zweifach, Adam
2018-05-01
We previously developed a flow cytometry assay that monitored lytic granule exocytosis in cytotoxic T lymphocytes stimulated by contacting beads coated with activating anti-CD3 antibodies. That assay was multiplexed in that responses of cells that did or did not receive the activating stimulus were distinguished via changes in light scatter accompanying binding of cells to beads, allowing us to discriminate compounds that activate responses on their own from compounds that enhance responses in cells that received the activating stimulus, all within a single sample. Here we add a second dimension of multiplexing by developing means to assess in a single sample the effects of treating cells with test compounds for different times. Bar-coding cells before adding them to test wells lets us determine compound treatment time while also monitoring activation status and response amplitude at the point of interrogation. This multiplexed assay is suitable for screening 96-well plates. We used it to screen compounds from the National Cancer Institute, identifying several compounds that enhance anti-LAMP1 responses. Multiple-treatment-time (MTT) screening enabled by bar-coding and read via high-throughput flow cytometry may be a generally useful method for facilitating the discovery of compounds of interest.
NASA Technical Reports Server (NTRS)
King, H. J.; Schnelker, D.; Ward, J. W.; Dulgeroff, C.; Vahrenkamp, R.
1972-01-01
The design, fabrication, and testing of thrust vectorable ion optical systems capable of controlling the thrust direction from both 5- and 30-cm diameter ion thrusters is described. Both systems are capable of greater than 10 deg thrust deflection in any azimuthal direction. The 5-cm system is electrostatic and hence has a short response time and minimal power consumption. It has recently been tested for more than 7500 hours on an operational thruster. The 30-cm system is mechanical, has a response time of the order of 1 min, and consumes less than 0.3% of the total system input power at full deflection angle.
French, Helen P; Fitzpatrick, Martina; FitzGerald, Oliver
2011-12-01
To compare the responsiveness of two self-report measures and three physical performance measures of function following physiotherapy for osteoarthritis of the knee. Single centre study in acute hospital setting. Patients referred for physiotherapy with osteoarthritis of the knee were recruited. The Western Ontario and McMaster Universities (WOMAC), Lequesne Algofunctional Index (LAI), timed-up-and-go test (TUGT), timed-stand test (TST) and six-minute walk test (6MWT) were administered at first and final physiotherapy visits. Wilcoxon Signed Rank tests were used to determine the effect of physiotherapy on each outcome. Responsiveness was calculated using effect size, standardised response mean and a median-based measure of responsiveness due to some outlying data. Thirty-nine patients with a mean age of 65.3 (standard deviation 6.9) years were investigated before and after a course of exercise-based physiotherapy. There was a significant improvement in all outcomes except the WOMAC scores. All measures demonstrated small effect sizes for all statistics (<0.50), except the 6MWT which was in the moderate range for one of the indices (standardised response mean 0.54). The LAI was more responsive than the WOMAC total score and the WOMAC physical function subscale for all responsiveness statistics, whilst the 6MWT was more responsive than the TST and the TUGT. The median-based effect size index produced the smallest effect sizes for all measures (0.1 to 0.43). These results can be used to guide decision making about which physical function outcome measures should be used to evaluate effectiveness of rehabilitation of people with osteoarthritis of the knee at group level in a clinical setting. Copyright © 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Macedo, Christiane de Souza Guerino; Vicente, Rafael Chagas; Cesário, Mauricio Donini; Guirro, Rinaldo Roberto de Jesus
2016-01-01
The purpose of this study was to evaluate the effects of cold-water immersion on the electromyographic (EMG) response of the lower limb and balance during unipodal jump landing. The evaluation comprised 40 individuals (20 basketball players and 20 non-athletes). The EMG response in the lateral gastrocnemius, tibialis anterior, fibular longus, rectus femoris, hamstring and gluteus medius; amplitude and mean speed of the centre of pressure, flight time and ground reaction force (GRF) were analysed. All volunteers remained for 20 min with their ankle immersed in cold-water, and were re-evaluated immediately post and after 10, 20 and 30 min of reheating. The Shapiro-Wilk test, Friedman test and Dunn's post test (P < 0.05) were used. The EMG response values decreased for the lateral gastrocnemius, tibialis anterior, fibular longus and rectus femoris of both athletes and non-athletes (P < 0.05). The comparison between the groups showed that the EMG response was lower for the athletes. Lower jump flight time and GRF, greater amplitude and mean speed of centre of pressure were predominant in the athletes. Cold-water immersion decreased the EMG activity of the lower limb, flight time and GRF and increased the amplitude and mean speed of centre of pressure.
Karsten, Bettina; Baker, Jonathan; Naclerio, Fernando; Klose, Andreas; Bianco, Antonino; Nimmerichter, Alfred
2018-02-01
To investigate single-day time-to-exhaustion (TTE) and time-trial (TT) -based laboratory tests values of critical power (CP), W prime (W'), and respective oxygen-uptake-kinetic responses. Twelve cyclists performed a maximal ramp test followed by 3 TTE and 3 TT efforts interspersed by 60 min recovery between efforts. Oxygen uptake ( V ˙ O 2 ) was measured during all trials. The mean response time was calculated as a description of the overall [Formula: see text]-kinetic response from the onset to 2 min of exercise. TTE-determined CP was 279 ± 52 W, and TT-determined CP was 276 ± 50 W (P = .237). Values of W' were 14.3 ± 3.4 kJ (TTE W') and 16.5 ± 4.2 kJ (TT W') (P = .028). While a high level of agreement (-12 to 17 W) and a low prediction error of 2.7% were established for CP, for W' limits of agreements were markedly lower (-8 to 3.7 kJ), with a prediction error of 18.8%. The mean standard error for TTE CP values was significantly higher than that for TT CP values (2.4% ± 1.9% vs 1.2% ± 0.7% W). The standard errors for TTE W' and TT W' were 11.2% ± 8.1% and 5.6% ± 3.6%, respectively. The [Formula: see text] response was significantly faster during TT (~22 s) than TTE (~28 s). The TT protocol with a 60-min recovery period offers a valid, time-saving, and less error-filled alternative to conventional and more recent testing methods. Results, however, cannot be transferred to W'.
Evaluation of an Indoor Sonic Boom Subjective Test Facility at NASA Langley Research Center
NASA Technical Reports Server (NTRS)
Loubeau, Alexandra; Rathsam, Jonathan; Klos, Jacob
2011-01-01
A sonic boom simulator at NASA Langley Research Center has been constructed for research on human response to low-amplitude sonic booms heard indoors. Research in this facility will ultimately lead to development of a psychoacoustic model for single indoor booms. The first subjective test was designed to explore indoor human response to variations in sonic boom rise time and amplitude. Another goal was to identify loudness level variability across listener locations within the facility. Finally, the test also served to evaluate the facility as a laboratory research tool for studying indoor human response to sonic booms. Subjects listened to test sounds and were asked to rate their annoyance relative to a reference boom. Measurements of test signals were conducted for objective analysis and correlation with subjective responses. Results confirm the functionality of the facility and effectiveness of the test methods and indicate that loudness level does not fully describe indoor annoyance to the selected sonic boom signals.
Structural-Vibration-Response Data Analysis
NASA Technical Reports Server (NTRS)
Smith, W. R.; Hechenlaible, R. N.; Perez, R. C.
1983-01-01
Computer program developed as structural-vibration-response data analysis tool for use in dynamic testing of Space Shuttle. Program provides fast and efficient time-domain least-squares curve-fitting procedure for reducing transient response data to obtain structural model frequencies and dampings from free-decay records. Procedure simultaneously identifies frequencies, damping values, and participation factors for noisy multiple-response records.
Metabolomics biomarkers to predict acamprosate treatment response in alcohol-dependent subjects.
Hinton, David J; Vázquez, Marely Santiago; Geske, Jennifer R; Hitschfeld, Mario J; Ho, Ada M C; Karpyak, Victor M; Biernacka, Joanna M; Choi, Doo-Sup
2017-05-31
Precision medicine for alcohol use disorder (AUD) allows optimal treatment of the right patient with the right drug at the right time. Here, we generated multivariable models incorporating clinical information and serum metabolite levels to predict acamprosate treatment response. The sample of 120 patients was randomly split into a training set (n = 80) and test set (n = 40) five independent times. Treatment response was defined as complete abstinence (no alcohol consumption during 3 months of acamprosate treatment) while nonresponse was defined as any alcohol consumption during this period. In each of the five training sets, we built a predictive model using a least absolute shrinkage and section operator (LASSO) penalized selection method and then evaluated the predictive performance of each model in the corresponding test set. The models predicted acamprosate treatment response with a mean sensitivity and specificity in the test sets of 0.83 and 0.31, respectively, suggesting our model performed well at predicting responders, but not non-responders (i.e. many non-responders were predicted to respond). Studies with larger sample sizes and additional biomarkers will expand the clinical utility of predictive algorithms for pharmaceutical response in AUD.
Sierra-Guzmán, Rafael; Jiménez, Fernando; Abián-Vicén, Javier
2018-05-01
Previous studies have reported the factors contributing to chronic ankle instability, which could lead to more effective treatments. However, factors such as the reflex response and ankle muscle strength have not been taken into account in previous investigations. Fifty recreational athletes with chronic ankle instability and 55 healthy controls were recruited. Peroneal reaction time in response to sudden inversion, isokinetic evertor muscle strength and dynamic balance with the Star Excursion Balance Test and the Biodex Stability System were measured. The relationship between the Cumberland Ankle Instability Tool score and performance on each test was assessed and a backward multiple linear regression analysis was conducted. Participants with chronic ankle instability showed prolonged peroneal reaction time, poor performance in the Biodex Stability System and decreased reach distance in the Star Excursion Balance Test. No significant differences were found in eversion and inversion peak torque. Moderate correlations were found between the Cumberland Ankle Instability Tool score and the peroneal reaction time and performance on the Star Excursion Balance Test. Peroneus brevis reaction time and the posteromedial and lateral directions of the Star Excursion Balance Test accounted for 36% of the variance in the Cumberland Ankle Instability Tool. Dynamic balance deficits and delayed peroneal reaction time are present in participants with chronic ankle instability. Peroneus brevis reaction time and the posteromedial and lateral directions of the Star Excursion Balance Test were the main contributing factors to the Cumberland Ankle Instability Tool score. No clear strength impairments were reported in unstable ankles. Copyright © 2018 Elsevier Ltd. All rights reserved.
Simulation test beds for the space station electrical power system
NASA Technical Reports Server (NTRS)
Sadler, Gerald G.
1988-01-01
NASA Lewis Research Center and its prime contractor are responsible for developing the electrical power system on the space station. The power system will be controlled by a network of distributed processors. Control software will be verified, validated, and tested in hardware and software test beds. Current plans for the software test bed involve using real time and nonreal time simulations of the power system. This paper will discuss the general simulation objectives and configurations, control architecture, interfaces between simulator and controls, types of tests, and facility configurations.
Resiliency in the Face of Adversity: A Short Longitudinal Test of the Trait Hypothesis.
Karaırmak, Özlem; Figley, Charles
2017-01-01
Resilience represents coping with adversity and is in line with a more positive paradigm for viewing responses to adversity. Most research has focused on resilience as coping-a state-based response to adversity. However, a competing hypothesis views resilience or resiliency as a trait that exists across time and types of adversity. We tested undergraduates enrolled in social work classes at a large southern university at two time periods during a single semester using measures of adversity, positive and negative affect, and trait-based resiliency. Consistent with the trait-based resiliency, and in contrast to state-based resilience, resiliency scores were not strongly correlated with adversity at both testing points but were with positive affect, and resiliency scores remained the same over time despite adversity variations. There was no gender or ethnic group difference in resilience scores. Black/African Americans reported significantly less negative affect and more positive affect than White/Caucasians.
46 CFR 4.06-1 - Responsibilities of the marine employer.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Responsibilities of the marine employer. 4.06-1 Section... MARINE CASUALTIES AND INVESTIGATIONS Mandatory Chemical Testing Following Serious Marine Incidents Involving Vessels in Commercial Service § 4.06-1 Responsibilities of the marine employer. (a) At the time of...
46 CFR 4.06-1 - Responsibilities of the marine employer.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Responsibilities of the marine employer. 4.06-1 Section... MARINE CASUALTIES AND INVESTIGATIONS Mandatory Chemical Testing Following Serious Marine Incidents Involving Vessels in Commercial Service § 4.06-1 Responsibilities of the marine employer. (a) At the time of...
46 CFR 4.06-1 - Responsibilities of the marine employer.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Responsibilities of the marine employer. 4.06-1 Section... MARINE CASUALTIES AND INVESTIGATIONS Mandatory Chemical Testing Following Serious Marine Incidents Involving Vessels in Commercial Service § 4.06-1 Responsibilities of the marine employer. (a) At the time of...
46 CFR 4.06-1 - Responsibilities of the marine employer.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Responsibilities of the marine employer. 4.06-1 Section... MARINE CASUALTIES AND INVESTIGATIONS Mandatory Chemical Testing Following Serious Marine Incidents Involving Vessels in Commercial Service § 4.06-1 Responsibilities of the marine employer. (a) At the time of...
46 CFR 4.06-1 - Responsibilities of the marine employer.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Responsibilities of the marine employer. 4.06-1 Section... MARINE CASUALTIES AND INVESTIGATIONS Mandatory Chemical Testing Following Serious Marine Incidents Involving Vessels in Commercial Service § 4.06-1 Responsibilities of the marine employer. (a) At the time of...
Anxiety responses to maximal exercise testing.
O'Connor, P J; Petruzzello, S J; Kubitz, K A; Robinson, T L
1995-01-01
The influence of maximal exercise testing on state anxiety was examined in three separate studies. Highly trained male distance runners (Study 1, n = 12) as well as college students with average (Study 2, n = 16) and below average (Study 3, n = 32) physical fitness levels completed graded maximal exercise tests. This last group was also randomly assigned to either a control or an 8 week training programme in order to determine the effect of increased fitness on the psychological responses to maximal exercise testing. Physical fitness was determined by the measurement of maximal oxygen uptake. State anxiety (State-Trait Anxiety Inventory) was assessed before and from 2-15 min following exercise. It was found that the state anxiety responses to maximal exercise testing were not influenced by re-testing or by 8 weeks of endurance training. Across the three study groups, the anxiety response was variable during the first 5 min following exercise testing; increases, decreases and no changes in anxiety were observed when compared to pre-exercise levels. The anxiety response to maximal exercise appeared to be dependent on the pre-exercise anxiety levels as well as the timing of the post-exercise assessments. It is concluded that maximal exercise testing can be associated with negative mood shifts during the first 5 min after exercise; however, this response is transitory and followed by positive mood shifts 10-15 min following such tests. PMID:7551769
Hardigan, Patrick C; Popovici, Ioana; Carvajal, Manuel J
2016-01-01
There is a gap between increasing demands from pharmacy journals, publishers, and reviewers for high survey response rates and the actual responses often obtained in the field by survey researchers. Presumably demands have been set high because response rates, times, and costs affect the validity and reliability of survey results. Explore the extent to which survey response rates, average response times, and economic costs are affected by conditions under which pharmacist workforce surveys are administered. A random sample of 7200 U.S. practicing pharmacists was selected. The sample was stratified by delivery method, questionnaire length, item placement, and gender of respondent for a total of 300 observations within each subgroup. A job satisfaction survey was administered during March-April 2012. Delivery method was the only classification showing significant differences in response rates and average response times. The postal mail procedure accounted for the highest response rates of completed surveys, but the email method exhibited the quickest turnaround. A hybrid approach, consisting of a combination of postal and electronic means, showed the least favorable results. Postal mail was 2.9 times more cost effective than the email approach and 4.6 times more cost effective than the hybrid approach. Researchers seeking to increase practicing pharmacists' survey participation and reduce response time and related costs can benefit from the analytical procedures tested here. Copyright © 2016 Elsevier Inc. All rights reserved.
Responsiveness of the Test of Basic Motor Skills of Children with Down Syndrome
ERIC Educational Resources Information Center
van den Heuvel, Marieke E.; de Jong, Inge; Lauteslager, Peter E. M.; Volman, M. J. M.
2009-01-01
The aim of this study was to examine the responsiveness of the Test of Basic Motor Skills for Children with Down Syndrome (BMS). Forty-one children with Down Syndrome, 3 to 36 months of age, participated in the study. Gross motor skills were assessed three times using the BMS and the Gross Motor Function Measure (GMFM) before and after a baseline…
ERIC Educational Resources Information Center
Group of Eight (NJ1), 2010
2010-01-01
The Group of Eight (Go8) applauds the government's intention to comprehensively reform the skilled migration program, and it welcomes the opportunity to submit this response to the General Skilled Migration (GSM) Points Test Discussion Paper. The Go8 has argued for some time that it is inappropriate to link international education to the skilled…
Stability of Rasch Scales over Time
ERIC Educational Resources Information Center
Taylor, Catherine S.; Lee, Yoonsun
2010-01-01
Item response theory (IRT) methods are generally used to create score scales for large-scale tests. Research has shown that IRT scales are stable across groups and over time. Most studies have focused on items that are dichotomously scored. Now Rasch and other IRT models are used to create scales for tests that include polytomously scored items.…
Yu Wei; Michael Bevers; Erin J. Belval
2015-01-01
Initial attack dispatch rules can help shorten fire suppression response times by providing easy-to-follow recommendations based on fire weather, discovery time, location, and other factors that may influence fire behavior and the appropriate response. A new procedure is combined with a stochastic programming model and tested in this study for designing initial attack...
McAuley, J D; Stewart, A L; Webber, E S; Cromwell, H C; Servatius, R J; Pang, K C H
2009-12-01
Inbred Wistar-Kyoto (WKY) rats have been proposed as a model of anxiety vulnerability as they display behavioral inhibition and a constellation of learning and reactivity abnormalities relative to outbred Sprague-Dawley (SD) rats. Together, the behaviors of the WKY rat suggest a hypervigilant state that may contribute to its anxiety vulnerability. To test this hypothesis, open-field behavior, acoustic startle, pre-pulse inhibition and timing behavior were assessed in WKY and Sprague-Dawley (SD) rats. Timing behavior was evaluated using a modified version of the peak-interval timing procedure. Training and testing of timing first occurred without audio-visual (AV) interference. Following this initial test, AV interference was included on some trials. Overall, WKY rats took much longer to leave the center of the arena, made fewer line crossings, and reared less, than did SD rats. WKY rats showed much greater startle responses to acoustic stimuli and significantly greater pre-pulse inhibition than did the SD rats. During timing conditions without AV interference, timing accuracy for both strains was similar; peak times for WKY and SD rats were not different. During interference conditions, however, the timing behavior of the two strains was very different. Whereas peak times for SD rats were similar between non-interference and interference conditions, peak times for WKY rats were shorter and response rates higher in interference conditions than in non-interference conditions. The enhanced acoustic startle response, greater prepulse inhibition and altered timing behavior with audio-visual interference supports a characterization of WKY strain as hypervigilant and provides further evidence for the use of the WKY strain as a model of anxiety vulnerability.
ERIC Educational Resources Information Center
Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.
2012-01-01
Background: Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods: Feasibility and test-retest reliability of a physical fitness test battery (Box and Block Test, Response Time Test, walking…
Pietsch, Hollie A; Bosch, Kelly E; Weyland, David R; Spratley, E Meade; Henderson, Kyvory A; Salzar, Robert S; Smith, Terrance A; Sagara, Brandon M; Demetropoulos, Constantine K; Dooley, Christopher J; Merkle, Andrew C
2016-11-01
Three laboratory simulated sub-injurious under-body blast (UBB) test conditions were conducted with whole-body Post Mortem Human Surrogates (PMHS) and the Warrior Assessment Injury Manikin (WIAMan) Technology Demonstrator (TD) to establish and assess UBB biofidelity of the WIAMan TD. Test conditions included a rigid floor and rigid seat with independently varied pulses. On the floor, peak velocities of 4 m/s and 6 m/s were applied with a 5 ms time to peak (TTP). The seat peak velocity was 4 m/s with varied TTP of 5 and 10 ms. Tests were conducted with and without personal protective equipment (PPE). PMHS response data was compiled into preliminary biofidelity response corridors (BRCs), which served as evaluation metrics for the WIAMan TD. Each WIAMan TD response was evaluated against the PMHS preliminary BRC for the loading and unloading phase of the signal time history using Correlation Analysis (CORA) software to assign a numerical score between 0 and 1. A weighted average of all responses was calculated to determine body region and whole body biofidelity scores for each test condition. The WIAMan TD received UBB biofidelity scores of 0.62 in Condition A, 0.59 in Condition B, and 0.63 in Condition C, putting it in the fair category (0.44-0.65). Body region responses with scores below a rating of good (0.65-0.84) indicate potential focus areas for the next generation of the WIAMan design.
Engineering evaluation of 24 channel multispectral scanner. [from flight tests
NASA Technical Reports Server (NTRS)
Lambeck, P. F.
1973-01-01
The results of flight tests to evaluate the performance of the 24 channel multispectral scanner are reported. The flight plan and test site are described along with the time response and channel registration. The gain and offset drift, and moire patterns are discussed. Aerial photographs of the test site are included.
Enhancing a Computer-Based Testing Environment with Optimum Item Response Time
ERIC Educational Resources Information Center
Delen, Erhan
2015-01-01
As technology has become more advanced and accessible in instructional settings, there has been an upward trend in computer-based testing in the last decades. The present experimental study examines students' behaviors during computer-based testing in two different conditions and explores how these conditions affect the test results. Results…
Speededness and Adaptive Testing
ERIC Educational Resources Information Center
van der Linden, Wim J.; Xiong, Xinhui
2013-01-01
Two simple constraints on the item parameters in a response--time model are proposed to control the speededness of an adaptive test. As the constraints are additive, they can easily be included in the constraint set for a shadow-test approach (STA) to adaptive testing. Alternatively, a simple heuristic is presented to control speededness in plain…
Effect of post cure time and temperature on the properties of two phenolic-fiber composites
NASA Technical Reports Server (NTRS)
Lucy, M. H.; Price, H. L.
1975-01-01
Some effects of post-cure time and temperature on the physicomechanical properties of a phenolic-asbestos and a phenolic-glass composite are studied. The molding and post-curing procedures are discussed along with physical and mechanical test results. It is found that the specific gravity of the panels tested decreased slightly but the hardness always increased with post cure, and that the mechanical properties had different patterns of response to increasing post-cure time and temperature. For tensile properties, strength decreased, modulus increased, and elongation at break exhibited little change. In general, the phenolic-asbestos showed more positive response to post cure than did the phenolic-glass. Mold venting is found to impart better properties to the composites concerned.
A PC parallel port button box provides millisecond response time accuracy under Linux.
Stewart, Neil
2006-02-01
For psychologists, it is sometimes necessary to measure people's reaction times to the nearest millisecond. This article describes how to use the PC parallel port to receive signals from a button box to achieve millisecond response time accuracy. The workings of the parallel port, the corresponding port addresses, and a simple Linux program for controlling the port are described. A test of the speed and reliability of button box signal detection is reported. If the reader is moderately familiar with Linux, this article should provide sufficient instruction for him or her to build and test his or her own parallel port button box. This article also describes how the parallel port could be used to control an external apparatus.
Effect of time of day on the vertical spinal creep response.
Puntumetakul, Rungthip; Trott, Patricia; Williams, Marie; Fulton, Ian
2009-01-01
Vertical spinal creep (VSC) is height loss during sustained postures over a set period of time. While total stature has been demonstrated to decrease throughout the day, whether a diurnal effect applies to the VSC response has not been reported. The aim of this study was to investigate whether time of day had an effect on the magnitude of the VSC response in young subjects asymptomatic for musculoskeletal pathologies. The VSC response was recorded over 25 min while subjects remained seated on the stadiometer, at three times (morning, midday and afternoon) on the same day, in 48 asymptomatic volunteers aged 20-39 years. While no significant differences were calculated for the magnitude of the VSC responses on the three occasions of testing, differences in magnitude of VSC response may have been confounded by preloading activities. Where magnitude of the VSC response is the primary outcome measure, measurement protocols should control preloading activities and continue to conduct measurements at the same time of day, until further studies conclusively refute the existence of a diurnal effect.
NASA Astrophysics Data System (ADS)
Guo, Yunlong
This dissertation focuses on nonisothermal physical aging of polymers from both experimental and theoretical aspects. The study concentrates on pure polymers rather than fiber-reinforced composites; this step removes several complicating factors to simplify the study. It is anticipated that the findings of this work can then be applied to composite materials applications. The physical aging tests in this work are performed using a dynamic mechanical analyzer (DMA). The viscoelastic response of glassy polymers under various loading and thermal histories are observed as stress-strain data at a series of time points. The first stage of the experimental work involves the characterization of the isothermal physical aging behavior of two advanced thermoplastics. The second stage conducts tests on the same materials with varying thermal histories and with long-term test duration. This forms the basis to assess and modify a nonisothermal physical aging model (KAHR-ate model). Based on the experimental findings, the KAHR-ate model has been revised by new correlations between aging shift factors and volume response; this revised model performed well in predicting the nonisothermal physical aging behavior of glassy polymers. In the work on isothermal physical aging, short-term creep and stress relaxation tests were performed at several temperatures within 15-35°C below the glass transition temperature (Tg) at various aging times, using the short-term test method established by Struik. Stress and strain levels were such that the materials remained in the linear viscoelastic regime. These curves were then shifted together to determine momentary master curves and shift rates. In order to validate the obtained isothermal physical aging behavior, the results of creep and stress relaxation testing were compared and shown to be consistent with one another using appropriate interconversion of the viscoelastic material functions. Time-temperature superposition of the master curves was also performed. The temperature shift factors and aging shift rates for both PEEK and PPS were consistent for both creep and stress relaxation test results. Nonisothermal physical aging was monitored by sequential short-term creep tests after a series of temperature jumps; the resulting strain histories were analyzed to determine aging shift factors (ate) for each of the creep tests. The nonisothermal aging response was predicted using the KAHR-ate model, which combines the KAHR model of volume recovery with a suitable linear relationship between aging shift factors and specific volume. The KAHR-ate model can be utilized to both predict aging response and to determine necessary model parameters from a set of aging shift factor data. For the PEEK and PPS materials considered in the current study, predictions of mechanical response were demonstrated to be in good agreement with the experimental results for several complicated thermal histories. In addition to short-term nonisothermal aging, long-term creep tests under identical thermal conditions were also analyzed. Effective time theory was unitized to predict long-term response under both isothermal and nonisothermal temperature histories. The long-term compliance after a series of temperature changes was predicted by the KAHR- ate model, and the theoretical predictions and experimental data showed good agreement for various thermal histories. Lastly, physical aging behavior of PPS near the glass transition temperature was investigated, in order to observe the mechanical response in the process of the evolution of the material into equilibrium. At several temperatures near Tg, the time need to reach equilibrium were determined by the creep test results at various aging times. In addition to isothermal physical aging, mechanical shift factors in the period of approaching equilibrium at a common temperature after temperature up-jumps and down-jumps are monitored from creep tests; prior to these temperature jumps, the materials were aged to reach equilibrium states. From these tests, asymmetry of approaching equilibrium phenomenon in ate was observed, which is first-time reported in the literature. This finding shows the similarity between the thermodynamic and mechanical properties during structural relaxation. This work will lead to improved understanding of the viscoelastic behavior of glassy polymers, which is important for better understanding and design of PMCs in elevated temperature applications. With the above findings, this dissertation deals with nonisothermal physical aging of glassy polymers, including both experimental characterization and constructing a framework for predictions of mechanical behavior of polymeric materials under complicated thermal conditions. (Abstract shortened by UMI.)
Excitation and desensitization of mouse rod photoreceptors in vivo following bright adapting light
Kang Derwent, Jennifer J; Qtaishat, Nasser M; Pepperberg, David R
2002-01-01
Electroretinographic (ERG) methods were used to determine response properties of mouse rod photoreceptors in vivo following adapting illumination that produced a significant extent of rhodopsin bleaching. Bleaching levels prevailing at ∼10 min and ∼20 min after the adapting exposure were on average 14% and 9%, respectively, based on the analysis of visual cycle retinoids in the eye tissues. Recovery of the rod response to the adapting light was monitored by analysing the ERG a-wave response to a bright probe flash presented at varying times during dark adaptation. A paired-flash procedure, in which the probe flash was presented at defined times after a weak test flash of fixed strength, was used to determine sensitivity of the rod response to the test flash. Recovery of the response to the adapting light was 80% complete at 13.5 ± 3.0 min (mean ± s.d.; n = 7) after adapting light offset. The adapting light caused prolonged desensitization of the weak-flash response derived from paired-flash data. By comparison with results obtained in the absence of the adapting exposure, desensitization determined with a test-probe interval of 80 ms was ∼fourfold after 5 min of dark adaptation and ∼twofold after 20 min. The results indicate, for mouse rods in vivo, that the time scale for recovery of weak-flash sensitivity substantially exceeds that for the recovery of circulating current following significant rhodopsin bleaching. The lingering desensitization may reflect a reduced efficiency of signal transmission in the phototransduction cascade distinct from that due to residual excitation. PMID:12015430
Computational Analysis of Arc-Jet Wedge Tests Including Ablation and Shape Change
NASA Technical Reports Server (NTRS)
Goekcen, Tahir; Chen, Yih-Kanq; Skokova, Kristina A.; Milos, Frank S.
2010-01-01
Coupled fluid-material response analyses of arc-jet wedge ablation tests conducted in a NASA Ames arc-jet facility are considered. These tests were conducted using blunt wedge models placed in a free jet downstream of the 6-inch diameter conical nozzle in the Ames 60-MW Interaction Heating Facility. The fluid analysis includes computational Navier-Stokes simulations of the nonequilibrium flowfield in the facility nozzle and test box as well as the flowfield over the models. The material response analysis includes simulation of two-dimensional surface ablation and internal heat conduction, thermal decomposition, and pyrolysis gas flow. For ablating test articles undergoing shape change, the material response and fluid analyses are coupled in order to calculate the time dependent surface heating and pressure distributions that result from shape change. The ablating material used in these arc-jet tests was Phenolic Impregnated Carbon Ablator. Effects of the test article shape change on fluid and material response simulations are demonstrated, and computational predictions of surface recession, shape change, and in-depth temperatures are compared with the experimental measurements.
Testing of focal plane arrays at the AEDC
NASA Astrophysics Data System (ADS)
Nicholson, Randy A.; Mead, Kimberly D.; Smith, Robert W.
1992-07-01
A facility was developed at the Arnold Engineering Development Center (AEDC) to provide complete radiometric characterization of focal plane arrays (FPAs). The highly versatile facility provides the capability to test single detectors, detector arrays, and hybrid FPAs. The primary component of the AEDC test facility is the Focal Plane Characterization Chamber (FPCC). The FPCC provides a cryogenic, low-background environment for the test focal plane. Focal plane testing in the FPCC includes flood source testing, during which the array is uniformly irradiated with IR radiation, and spot source testing, during which the target radiation is focused onto a single pixel or group of pixels. During flood source testing, performance parameters such as power consumption, responsivity, noise equivalent input, dynamic range, radiometric stability, recovery time, and array uniformity can be assessed. Crosstalk is evaluated during spot source testing. Spectral response testing is performed in a spectral response test station using a three-grating monochromator. Because the chamber can accommodate several types of testing in a single test installation, a high throughput rate and good economy of operation are possible.
THE INFLUENCE OF EXTRINSIC REINFORCEMENT ON CHILDREN WITH HEAVY PRENATAL ALCOHOL EXPOSURE
Graham, Diana M.; Glass, Leila; Mattson, Sarah N.
2016-01-01
Background Prenatal alcohol exposure affects inhibitory control and other aspects of attention and executive function. However, the efficacy of extrinsic reinforcement on these behaviors has not been tested. Methods Alcohol-exposed children (AE; n=34), children with ADHD (ADHD; n=23), and controls (CON; n=31) completed a flanker task with four reward conditions (no reward, reward, reward+occasional response cost, equal probability of reward+response cost). Inhibitory control was tested in the no reward conditions using a 3(group) x 2(flanker type) ANCOVA. Response to reinforcement was tested using 3(group) x 4(reward condition) x 4(flanker type) ANCOVA. Response time (RT) and accuracy were tested independently. Results Groups did not differ on demographic variables. The flanker task was successful in taxing interference control, an aspect of executive attention (i.e., responses to incongruent stimuli were slower than to congruent stimuli) and the AE group demonstrated impaired executive control over the other groups. Overall, the AE group had significantly slower response times compared to the CON and ADHD groups, which did not differ. However, reinforcement improved RT in all groups. While occasional response cost had the greatest benefit in the CON group, the type of reinforcement did not differentially affect the AE and ADHD groups. Accuracy across reward conditions did not differ by group, but was dependent on flanker type and reward condition. Conclusions Alcohol-exposed children, but not children with ADHD, had impaired interference control in comparison to controls, supporting a differential neurobehavioral profile in these two groups. Both clinical groups were equally affected by introduction of reinforcement, although the type of reinforcement did not differentially affect performance as it did in the control group, suggesting that reward or response cost could be used interchangeably to result in the same benefit. PMID:26842253
Aircraft Cargo Compartment Fire Test Simulation Program
NASA Technical Reports Server (NTRS)
Blumke, R. E.
1977-01-01
The objective of the test was to assess fire containment and fire extinguishment in the cargo by reducing the ventilation through the cargo compartment. Parameters which were measured included ignition time, burnthrough time, and physical damage to the cargo liner, composition of selected combustible gases, temperature-time histories, heat flux, and detector response. The ignitor load was made of a typical cargo consisting of filled cardboard cartons occupying 50% of the compartment volume.
ERIC Educational Resources Information Center
Okanda, Mako; Itakura, Shoji
2011-01-01
Previous studies have suggested that younger preschoolers exhibit a yes bias due to underdeveloped cognitive abilities, whereas older preschoolers exhibit a response bias due to other factors. To test this hypothesis, we investigated the response latency to yes-no questions pertaining to familiar and unfamiliar objects in 3- to 6-year-olds. The…
The effect of lithium chloride on one-trial passive avoidance learning in rats.
Johnson, F N
1976-01-01
1 Expression of a one-trial passive avoidance learning response in rats was examined following injections of lithium chloride or sodium chloride before and after initial training and before the first day of testing. Five tests were given at daily intervals, 24 h after training being the time of the first test. 2. Lithium given before the first day of testing impaired response expression on the first and all subsequent days of testing; the rate of extinction was unaffected. 3. Given both before and immediately after initial training, lithium impaired response expression on the first day of testing but slowed down the subsequent rate of extinction, leading eventually to improved performance on the fifth day, as compared with placebo-treated control subjects. 4. The results are interpreted in the light of the hypothesis that lithium impaired the central processing of sensory information. PMID:1252666
Response moderation models for conditional dependence between response time and response accuracy.
Bolsinova, Maria; Tijmstra, Jesper; Molenaar, Dylan
2017-05-01
It is becoming more feasible and common to register response times in the application of psychometric tests. Researchers thus have the opportunity to jointly model response accuracy and response time, which provides users with more relevant information. The most common choice is to use the hierarchical model (van der Linden, 2007, Psychometrika, 72, 287), which assumes conditional independence between response time and accuracy, given a person's speed and ability. However, this assumption may be violated in practice if, for example, persons vary their speed or differ in their response strategies, leading to conditional dependence between response time and accuracy and confounding measurement. We propose six nested hierarchical models for response time and accuracy that allow for conditional dependence, and discuss their relationship to existing models. Unlike existing approaches, the proposed hierarchical models allow for various forms of conditional dependence in the model and allow the effect of continuous residual response time on response accuracy to be item-specific, person-specific, or both. Estimation procedures for the models are proposed, as well as two information criteria that can be used for model selection. Parameter recovery and usefulness of the information criteria are investigated using simulation, indicating that the procedure works well and is likely to select the appropriate model. Two empirical applications are discussed to illustrate the different types of conditional dependence that may occur in practice and how these can be captured using the proposed hierarchical models. © 2016 The British Psychological Society.
NASA Astrophysics Data System (ADS)
Fisher, Lee E.; Ayers, Christopher A.; Ciollaro, Mattia; Ventura, Valérie; Weber, Douglas J.; Gaunt, Robert A.
2014-06-01
Objective. This study describes results of primary afferent neural microstimulation experiments using microelectrode arrays implanted chronically in the lumbar dorsal root ganglia (DRG) of four cats. The goal was to test the stability and selectivity of these microelectrode arrays as a potential interface for restoration of somatosensory feedback after damage to the nervous system such as amputation. Approach. A five-contact nerve-cuff electrode implanted on the sciatic nerve was used to record the antidromic compound action potential response to DRG microstimulation (2-15 µA biphasic pulses, 200 µs cathodal pulse width), and the threshold for eliciting a response was tracked over time. Recorded responses were segregated based on conduction velocity to determine thresholds for recruiting Group I and Group II/Aβ primary afferent fibers. Main results. Thresholds were initially low (5.1 ± 2.3 µA for Group I and 6.3 ± 2.0 µA for Group II/Aβ) and increased over time. Additionally the number of electrodes with thresholds less than or equal to 15 µA decreased over time. Approximately 12% of tested electrodes continued to elicit responses at 15 µA up to 26 weeks after implantation. Higher stimulation intensities (up to 30 µA) were tested in one cat at 23 weeks post-implantation yielding responses on over 20 additional electrodes. Within the first six weeks after implantation, approximately equal numbers of electrodes elicited only Group I or Group II/Aβ responses at threshold, but the relative proportion of Group II/Aβ responses decreased over time. Significance. These results suggest that it is possible to activate Group I or Group II/Aβ primary afferent fibers in isolation with penetrating microelectrode arrays implanted in the DRG, and that those responses can be elicited up to 26 weeks after implantation, although it may be difficult to achieve a consistent response day-to-day with currently available electrode technology. The DRG are compelling targets for sensory neuroprostheses with potential to achieve recruitment of a range of sensory fiber types over multiple months after implantation.
End-to-end test of the electron-proton spectrometer
NASA Technical Reports Server (NTRS)
Cash, B. L.
1972-01-01
A series of end-to-end tests were performed to demonstrate the proper functioning of the complete Electron-Proton Spectrometer (EPS). The purpose of the tests was to provide experimental verification of the design and to provide a complete functional performance check of the instrument from the excitation of the sensors to and including the data processor and equipment test set. Each of the channels of the EPS was exposed to a calibrated beam of energetic particles, and counts were accumulated for a predetermined period of time for each of several energies. The counts were related to the known flux of particles to give a monodirectional response function for each channel. The measured response function of the test unit was compared to the response function determined for the calibration sensors from the data taken from the calibration program.
Patterson, Shane B.; Landrum, Michael L; Okulicz, Jason F.
2014-01-01
Background Delayed-type hypersensitivity (DTH) test responsiveness is associated with HIV disease progression; however it is unknown whether other immune markers, such as hepatitis B virus (HBV) vaccine seroresponse, also predict HIV outcomes. Methods Eligible participants received HBV vaccine after HIV diagnosis, had non-anergic DTH testing at the time of last HBV vaccination, and available post-vaccine HBV antibody responses. The risk of progression to AIDS or death from the time of last HBV vaccination was evaluated. Results Of 369 eligible participants with non-anergic DTH responses, 148 (40%) were HBV vaccine responders. In a multivariate model adjusted for age, CD4 count, viral load, and number of vaccinations, HBV vaccine non-responders had an increased risk of progression to AIDS or death (HR 1.81; 95% CI, 1.03–3.19). Conclusions HBV vaccine seroresponses were independent of DTH responses which suggest that non-response to HBV vaccine is not solely due to cell-mediated immune dysfunction in HIV-infected persons. PMID:24793945
Tiwari, Nishidha; Tiwari, Shilpi; Thakur, Ruchi; Agrawal, Nikita; Shashikiran, N D; Singla, Shilpy
2015-01-01
Dental treatment is usually a poignant phenomenon for children. Projective scales are preferred over psychometric scales to recognize it, and to obtain the self-report from children. The aims were to evaluate treatment related fear using a newly developed fear scale for children, fear assessment picture scale (FAPS), and anxiety with colored version of modified facial affective scale (MFAS) - three faces along with physiologic responses (pulse rate and oxygen saturation) obtained by pulse oximeter before and during pulpectomy procedure. Total, 60 children of age 6-8 years who were visiting the dental hospital for the first time and needed pulpectomy treatment were selected. Children selected were of sound physical, physiological, and mental condition. Two projective scales were used; one to assess fear - FAPS and to assess anxiety - colored version of MFAS - three faces. These were co-related with the physiological responses (oxygen saturation and pulse rate) of children obtained by pulse oximeter before and during the pulpectomy procedure. Shapiro-Wilk test, McNemar's test, Wilcoxon signed ranks test, Kruskal-Wallis test, Mann-Whitney test were applied in the study. The physiological responses showed association with FAPS and MFAS though not significant. However, oxygen saturation with MFAS showed a significant change between "no anxiety" and "some anxiety" as quantified by Kruskal-Wallis test value 6.287, P = 0.043 (<0.05) before pulpectomy procedure. The FAPS can prove to be a pragmatic tool in spotting the fear among young children. This test is easy and fast to apply on children and reduces the chair-side time.
NASA Technical Reports Server (NTRS)
Wunsch, S. A.; Muller-Delp, J.; Delp, M. D.
2000-01-01
At the onset of dynamic exercise, muscle blood flow increases within 1-2 s. It has been postulated that local vasodilatory agents produced by the vascular endothelium or the muscle itself contribute to this response. We hypothesized that only vasodilators that act directly on the vascular smooth muscle could produce vasodilation of skeletal muscle arterioles in <2 s. To test this hypothesis, we determined the time course of the vasodilatory response of isolated skeletal muscle arterioles to direct application of potassium chloride, adenosine, acetylcholine, and sodium nitroprusside. Soleus and gastrocnemius muscles were dissected from the hindlimbs of male Sprague-Dawley rats. First-order arterioles (100-200 microm) were isolated, cannulated on micropipettes, and pressurized to 60 cmH(2)O in an organ bath. Vasodilatory agents were added directly to the bath, and diameter responses of the arterioles were recorded in real time on a videotape recorder. Frame-by-frame analysis of the diameter responses indicated that none of the vasodilator agents tested produced significant diameter increases in <4 s in either soleus or gastrocnemius muscle arterioles. These results indicate that, although these local vasodilators produce significant vasodilation of skeletal muscle resistance arterioles, these responses are not rapid enough (within 1-2 s) to contribute to the initiation of the exercise hyperemic response at the onset of dynamic exercise.
Code of Federal Regulations, 2011 CFR
2011-07-01
... limitation is not dependent upon any past production or activity level. (1) If the expected mix of products... acceptable if the response from the high-level calibration gas is at least 20 times the standard deviation of..., appendix A is acceptable if the response from the high-level calibration gas is at least 20 times the...
Dwight K. Lauer; Harold E. Quicke; David Adams
2006-01-01
The use of Chopper® (BASF Corporation, Research Triangle Park, NC) herbicide applied with an oil and water carrier was tested for site preparation. Tests were installed at eight locations to examine slash pine (Pinus elliottii Engelm.) response and vegetation control with different vegetation types and timings of bedding. Chopper was applied in...
Predicting Assessment Outcomes: The Effect of Full-Time and Part-Time Faculty
ERIC Educational Resources Information Center
Gerlich, R. Nicholas; Sollosy, Marc
2010-01-01
Assessments have risen in prominence in colleges of business, in response to requirements of accrediting agencies. Among the forms of assessment are embedded exams within courses, often in the form of multiple-choice tests near the end of the semester. These tests can be stand-alone comprehensive exercises, or comprise a small portion of a larger…
Pulse-train Stimulation of Primary Somatosensory Cortex Blocks Pain Perception in Tail Clip Test
Lee, Soohyun; Hwang, Eunjin; Lee, Dongmyeong
2017-01-01
Human studies of brain stimulation have demonstrated modulatory effects on the perception of pain. However, whether the primary somatosensory cortical activity is associated with antinociceptive responses remains unknown. Therefore, we examined the antinociceptive effects of neuronal activity evoked by optogenetic stimulation of primary somatosensory cortex. Optogenetic transgenic mice were subjected to continuous or pulse-train optogenetic stimulation of the primary somatosensory cortex at frequencies of 15, 30, and 40 Hz, during a tail clip test. Reaction time was measured using a digital high-speed video camera. Pulse-train optogenetic stimulation of primary somatosensory cortex showed a delayed pain response with respect to a tail clip, whereas no significant change in reaction time was observed with continuous stimulation. In response to the pulse-train stimulation, video monitoring and local field potential recording revealed associated paw movement and sensorimotor rhythms, respectively. Our results show that optogenetic stimulation of primary somatosensory cortex at beta and gamma frequencies blocks transmission of pain signals in tail clip test. PMID:28442945
DOT National Transportation Integrated Search
1995-10-01
REAL-TIME TRAFFIC INFORMATION, ROUTE GUIDANCE, ROUTE PLANNING, INTELLIGENT VEHICLE INITIATIVE OR IVI ">">KEYWORDS: OPERATIONAL TESTS, TRAVTEK, ADVANCED TRAVELER INFORMATION SYSTEMS OR ATIS, ADVANCED TRAFFIC MANAGEMENT SYSTEMS OR ATMS, INTELLI...
Effect of Students' Perceptions of Course Load on Test Anxiety
Sansgiry, Sujit S.; Sail, Kavita
2006-01-01
Objectives The objective of this study was to examine the association between student perceptions of course load, their ability to manage time, and test anxiety. Methods A survey was self-administered to all students (professional years 1 through 4) enrolled in the PharmD curriculum at the University of Houston (2001) with items measuring test anxiety, perceived course load, and ability to manage time. Results One hundred ninety-eight students participated in the survey (response rate P1 = 48%, P2 = 52%, P3 = 52%, P4 = 72%). There was a significant difference in students' perception of course load, ability to manage time, and test anxiety scores across the 4 years. Test anxiety was positively correlated with students' perceptions of course load and negatively related to their ability to manage time with course work. Conclusions Students' perception of course load and their ability to manage time with their course work is associated with test anxiety. Future studies should evaluate the role of stress/time management programs to reduce stress and anxiety. PMID:17149404
Effect of students' perceptions of course load on test anxiety.
Sansgiry, Sujit S; Sail, Kavita
2006-04-15
The objective of this study was to examine the association between student perceptions of course load, their ability to manage time, and test anxiety. A survey was self-administered to all students (professional years 1 through 4) enrolled in the PharmD curriculum at the University of Houston (2001) with items measuring test anxiety, perceived course load, and ability to manage time. One hundred ninety-eight students participated in the survey (response rate P1 = 48%, P2 = 52%, P3 = 52%, P4 = 72%). There was a significant difference in students' perception of course load, ability to manage time, and test anxiety scores across the 4 years. Test anxiety was positively correlated with students' perceptions of course load and negatively related to their ability to manage time with course work. Students' perception of course load and their ability to manage time with their course work is associated with test anxiety. Future studies should evaluate the role of stress/time management programs to reduce stress and anxiety.
On the Issue of Item Selection in Computerized Adaptive Testing with Response Times
ERIC Educational Resources Information Center
Veldkamp, Bernard P.
2016-01-01
Many standardized tests are now administered via computer rather than paper-and-pencil format. The computer-based delivery mode brings with it certain advantages. One advantage is the ability to adapt the difficulty level of the test to the ability level of the test taker in what has been termed computerized adaptive testing (CAT). A second…
46 CFR 162.050-35 - Bilge alarm: Approval tests.
Code of Federal Regulations, 2012 CFR
2012-10-01
... water only and any zero drift must be recorded. (h) Test No. 7A Response Time Test. (1) The bilge alarm... using the method described in § 162.050-39. (b) Test No. 1A Calibration and Zero Test. (1) The bilge alarm is calibrated and zeroed to manufacturer's instructions. (2) It is then fed with water for 15...
46 CFR 162.050-35 - Bilge alarm: Approval tests.
Code of Federal Regulations, 2014 CFR
2014-10-01
... water only and any zero drift must be recorded. (h) Test No. 7A Response Time Test. (1) The bilge alarm... using the method described in § 162.050-39. (b) Test No. 1A Calibration and Zero Test. (1) The bilge alarm is calibrated and zeroed to manufacturer's instructions. (2) It is then fed with water for 15...
46 CFR 162.050-35 - Bilge alarm: Approval tests.
Code of Federal Regulations, 2013 CFR
2013-10-01
... water only and any zero drift must be recorded. (h) Test No. 7A Response Time Test. (1) The bilge alarm... using the method described in § 162.050-39. (b) Test No. 1A Calibration and Zero Test. (1) The bilge alarm is calibrated and zeroed to manufacturer's instructions. (2) It is then fed with water for 15...
ERIC Educational Resources Information Center
Brom, Michael Wayde
2016-01-01
Studies have shown that test anxiety has become more prevalent since the adoption of the No Child Left Behind Act in 2001 and that test anxiety negatively affects student achievement. Early research viewed test anxiety as being a unidimensional construct; however, recent research has purported that test anxiety is a multidimensional construct.…
Trends in computer applications in science assessment
NASA Astrophysics Data System (ADS)
Kumar, David D.; Helgeson, Stanley L.
1995-03-01
Seven computer applications to science assessment are reviewed. Conventional test administration includes record keeping, grading, and managing test banks. Multiple-choice testing involves forced selection of an answer from a menu, whereas constructed-response testing involves options for students to present their answers within a set standard deviation. Adaptive testing attempts to individualize the test to minimize the number of items and time needed to assess a student's knowledge. Figurai response testing assesses science proficiency in pictorial or graphic mode and requires the student to construct a mental image rather than selecting a response from a multiple choice menu. Simulations have been found useful for performance assessment on a large-scale basis in part because they make it possible to independently specify different aspects of a real experiment. An emerging approach to performance assessment is solution pathway analysis, which permits the analysis of the steps a student takes in solving a problem. Virtually all computer-based testing systems improve the quality and efficiency of record keeping and data analysis.
Characteristics of ground motion at permafrost sites along the Qinghai-Tibet railway
Wang, L.; Wu, Z.; Sun, Jielun; Liu, Xiuying; Wang, Z.
2009-01-01
Based on 14 typical drilling holes distributed in the permafrost areas along the Qinghai-Tibet railway, the distribution of wave velocities of soils in the permafrost regions were determined. Using results of dynamic triaxial tests, the results of dynamic triaxiality test and time histories of ground motion acceleration in this area, characteristics of ground motion response were analyzed for these permafrost sites for time histories of ground accelerations with three exceedance probabilities (63%, 10% and 2%). The influence of ground temperature on the seismic displacement, velocity, acceleration and response spectrum on the surface of permafrost were also studied. ?? 2008 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Grana, D. C.
1979-01-01
The results of two research programs to determine the optimum detector design for measuring fecal coliforms in saline waters for operational systems are presented. One program was concerned with the effects of temperature and salinity on endpoint response time, and the other, the interaction between electrode configurations and the test organisms. Test results show that the endpoint response time is related to salinity and seawater temperature; however, these results can be minimized by the correct choice of growth media. Electrode configurations were developed from stainless steel, Parlodion-coated stainless steel, and platinum that circumvented problems associated with the commercial redox electrodes.
Fundamental investigation of vacuum PD tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suyama, M.; Hirano, K.; Asakura, N.
1994-08-01
As a fundamental study of photodiodes (PDs) for electron bombardment, two types of PDs have been experimentally investigated to be applied in electron tubes. A PD bombarded from the front surface (FB-PD), where pn junction of planer structure existed, was evaluated to measure fast response characteristics such as 2.1ns in rise time, however, more than an order of magnitude increase of dark current was also confirmed after a long term stability test of 1,000 hours. On the other hand, a PD bombarded by electrons from the rear surface (RB-PD) showed no increase of dark current after the stability test andmore » fast rise time of 2.7ns. However, it was clarified that the rise time of RB-PD depended on applied voltage to the PD, and applied voltage of 200 V was necessary to achieve such fast response. Since it was a much higher voltage than expected, some modifications may be necessary to achieve fast response with lower applied voltage, considering the yield of the PDs. Comparison of two types of PDs on some other characteristics are discussed. Preliminary test results of an electron bombardment APD are also discussed.« less
ERIC Educational Resources Information Center
Thissen, David
2015-01-01
In "Adapting Educational Measurement to the Demands of Test-Based Accountability" Koretz takes the time-honored engineering approach to educational measurement, identifying specific problems with current practice and proposing minimal modifications of the system to alleviate those problems. In response to that article, David Thissen…
How gender and task difficulty affect a sport-protective response in young adults
Lipps, David B.; Eckner, James T.; Richardson, James K.; Ashton-Miller, James A.
2013-01-01
We tested the hypotheses that gender and task difficulty affect the reaction, movement, and total response times associated with performing a head protective response. Twenty-four healthy young adults (13 females) performed a protective response of raising their hands from waist level to block a foam ball fired at their head from an air cannon. Participants initially stood 8.25 m away from the cannon (‘low difficulty’), and were moved successively closer in 60 cm increments until they failed to block at least 5 of 8 balls (‘high difficulty’). Limb motion was quantified using optoelectronic markers on the participants’ left wrist. Males had significantly faster total response times (p = 0.042), a trend towards faster movement times (p = 0.054), and faster peak wrist velocity (p < .001) and acceleration (p = 0.032) than females. Reaction time, movement time, and total response time were significantly faster under high difficulty conditions for both genders (p < .001). This study suggests that baseball and softball pitchers and fielders should have sufficient time to protect their head from a batted ball under optimal conditions if they are adequately prepared for the task. PMID:23234296
A Study of Computer-Administered Stradaptive Ability Testing. Research Report 75-4.
ERIC Educational Resources Information Center
Vale, C. David; Weiss, David J.
A conventional vocabulary test and two forms of a stradaptive vocabulary test were administered by a time-shared computer system to undergraduate college students. The two stradaptive tests differed in that one counted question mark responses (i.e., omitted items) as incorrect and the other ignored items responded to with question marks.…
Arbes, Samuel J; Gergen, Peter J; Elliott, Leslie; Zeldin, Darryl C
2005-08-01
Allergy skin tests were administered in the second and third National Health and Nutrition Examination Surveys (NHANES II and III) conducted in the United States from 1976 through 1980 and 1988 through 1994, respectively. This study estimated positive skin test response rates in NHANES III and identified predictors of one or more positive test responses. Comparisons with NHANES II were also made. In NHANES III, 10 allergens and 2 controls were tested in all subjects aged 6 to 19 years and a random half-sample of subjects aged 20 to 59 years. A wheal-based definition of a positive test response was used. In NHANES III, 54.3% of the population had positive test responses to 1 or more allergens. Prevalences were 27.5% for dust mite, 26.9% for perennial rye, 26.2% for short ragweed, 26.1% for German cockroach, 18.1% for Bermuda grass, 17.0% for cat, 15.2% for Russian thistle, 13.2% for white oak, 12.9% for Alternaria alternata, and 8.6% for peanut. Among those with positive test responses, the median number of positive responses was 3.0. Adjusted odds of a positive test response were higher for the following variables: age of 20 to 29 years, male sex, minority race, western region, old homes, and lower serum cotinine levels. For the 6 allergens common to NHANES II and III, prevalences were 2.1 to 5.5 times higher in NHANES III. The majority of the US population represented in NHANES III was sensitized to 1 or more allergens. Whether the higher prevalences observed in NHANES III reflect true changes in prevalence or methodological differences between the surveys cannot be determined with certainty.
van Schie, Mojca K M; Werth, Esther; Lammers, Gert Jan; Overeem, Sebastiaan; Baumann, Christian R; Fronczek, Rolf
2016-08-01
This two-centre observational study of vigilance measurements assessed the feasibility of vigilance measurements on multiple days using the Sustained Attention to Response Task and the Psychomotor Vigilance Test with portable task equipment, and subsequently assessed the effect of sodium oxybate treatment on vigilance in patients with narcolepsy. Twenty-six patients with narcolepsy and 15 healthy controls were included. The study comprised two in-laboratory days for the Maintenance of Wakefulness Test and the Oxford Sleep Resistance test, followed by 7-day portable vigilance battery measurements. This procedure was repeated for patients with narcolepsy after at least 3 months of stable treatment with sodium oxybate. Patients with narcolepsy had a higher Sustained Attention to Response Task error count, lower Psychomotor Vigilance Test reciprocal reaction time, higher Oxford Sleep Resistance test omission error count adjusted for test duration (Oxford Sleep Resistance testOMIS / MIN ), and lower Oxford Sleep Resistance test and Maintenance of Wakefulness Test sleep latency compared with controls (all P < 0.01). Treatment with sodium oxybate was associated with a longer Maintenance of Wakefulness Test sleep latency (P < 0.01), lower Oxford Sleep Resistance testOMIS / MIN (P = 0.01) and a lower Sustained Attention to Response Task error count (P = 0.01) in patients with narcolepsy, but not with absolute changes in Oxford Sleep Resistance test sleep latency or Psychomotor Vigilance Test reciprocal reaction time. It was concluded that portable measurements of sustained attention as well as in-laboratory Oxford Sleep Resistance test and Maintenance of Wakefulness Test measurements revealed worse performance for narcoleptic patients compared with controls, and that sodium oxybate was associated with an improvement of sustained attention and a better resistance to sleep. © 2016 European Sleep Research Society.
Distinguishing Fast and Slow Processes in Accuracy - Response Time Data.
Coomans, Frederik; Hofman, Abe; Brinkhuis, Matthieu; van der Maas, Han L J; Maris, Gunter
2016-01-01
We investigate the relation between speed and accuracy within problem solving in its simplest non-trivial form. We consider tests with only two items and code the item responses in two binary variables: one indicating the response accuracy, and one indicating the response speed. Despite being a very basic setup, it enables us to study item pairs stemming from a broad range of domains such as basic arithmetic, first language learning, intelligence-related problems, and chess, with large numbers of observations for every pair of problems under consideration. We carry out a survey over a large number of such item pairs and compare three types of psychometric accuracy-response time models present in the literature: two 'one-process' models, the first of which models accuracy and response time as conditionally independent and the second of which models accuracy and response time as conditionally dependent, and a 'two-process' model which models accuracy contingent on response time. We find that the data clearly violates the restrictions imposed by both one-process models and requires additional complexity which is parsimoniously provided by the two-process model. We supplement our survey with an analysis of the erroneous responses for an example item pair and demonstrate that there are very significant differences between the types of errors in fast and slow responses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1990-01-01
The present conference on flight testing encompasses avionics, flight-testing programs, technologies for flight-test predictions and measurements, testing tools, analysis methods, targeting techniques, and flightline testing. Specific issues addressed include flight testing of a digital terrain-following system, a digital Doppler rate-of-descent indicator, a high-technology testbed, a low-altitude air-refueling flight-test program, techniques for in-flight frequency-response testing for helicopters, limit-cycle oscillation and flight-flutter testing, and the research flight test of a scaled unmanned air vehicle. Also addressed are AV-8B V/STOL performance analysis, incorporating pilot-response time in failure-case testing, the development of pitot static flightline testing, targeting techniques for ground-based hover testing, a low-profilemore » microsensor for aerodynamic pressure measurement, and the use of a variable-capacitance accelerometer for flight-test measurements.« less
Analysis and testing of a space crane articulating joint testbed
NASA Technical Reports Server (NTRS)
Sutter, Thomas R.; Wu, K. Chauncey
1992-01-01
The topics are presented in viewgraph form and include: space crane concept with mobile base; mechanical versus structural articulating joint; articulating joint test bed and reference truss; static and dynamic characterization completed for space crane reference truss configuration; improved linear actuators reduce articulating joint test bed backlash; 1-DOF space crane slew maneuver; boom 2 tip transient response finite element dynamic model; boom 2 tip transient response shear-corrected component modes torque driver profile; peak root member force vs. slew time torque driver profile; and open loop control of space crane motion.
Otero, Carles; Aldaba, Mikel; López, Silvia; Díaz-Doutón, Fernando; Vera-Díaz, Fuensanta A; Pujol, Jaume
2018-06-01
To study the accommodative dynamics for predictable and unpredictable stimuli using manual and automated accommodative facility tests Materials and Methods: Seventeen young healthy subjects were tested monocularly in two consecutive sessions, using five different conditions. Two conditions replicated the conventional monocular accommodative facility tests for far and near distances, performed with manually held flippers. The other three conditions were automated and conducted using an electro-optical system and open-field autorefractor. Two of the three automated conditions replicated the predictable manual accommodative facility tests. The last automated condition was a hybrid approach using a novel method whereby far and near-accommodative-facility tests were randomly integrated into a single test of four unpredictable accommodative demands. The within-subject standard deviations for far- and near-distance-accommodative reversals were (±1,±1) cycles per minute (cpm) for the manual flipper accommodative facility conditions and (±3, ±4) cpm for the automated conditions. The 95% limits of agreement between the manual and the automated conditions for far and near distances were poor: (-18, 12) and (-15, 3). During the hybrid unpredictable condition, the response time and accommodative response parameters were significantly (p < 0.05) larger for accommodation than disaccommodation responses for high accommodative demands only. The response times during the transitions 0.17/2.17 D and 0.50/4.50 D appeared to be indistinguishable between the hybrid unpredictable and the conventional predictable automated tests. The automated accommodative facility test does not agree with the manual flipper test results. Operator delays in flipping the lens may account for these differences. This novel test, using unpredictable stimuli, provides a more comprehensive examination of accommodative dynamics than conventional manual accommodative facility tests. Unexpectedly, the unpredictability of the stimulus did not to affect accommodation dynamics. Further studies are needed to evaluate the sensitivity of this novel hybrid technique on individuals with accommodative anomalies.
NASA Technical Reports Server (NTRS)
Torres-Pomales, Wilfredo; Malekpour, Mahyar R.; Miner, Paul S.; Koppen, Sandra V.
2008-01-01
This report describes the design of the test articles and monitoring systems developed to characterize the response of a fault-tolerant computer communication system when stressed beyond the theoretical limits for guaranteed correct performance. A high-intensity radiated electromagnetic field (HIRF) environment was selected as the means of injecting faults, as such environments are known to have the potential to cause arbitrary and coincident common-mode fault manifestations that can overwhelm redundancy management mechanisms. The monitors generate stimuli for the systems-under-test (SUTs) and collect data in real-time on the internal state and the response at the external interfaces. A real-time health assessment capability was developed to support the automation of the test. A detailed description of the nature and structure of the collected data is included. The goal of the report is to provide insight into the design and operation of these systems, and to serve as a reference document for use in post-test analyses.
Virtual geotechnical laboratory experiments using a simulator
NASA Astrophysics Data System (ADS)
Penumadu, Dayakar; Zhao, Rongda; Frost, David
2000-04-01
The details of a test simulator that provides a realistic environment for performing virtual laboratory experimentals in soil mechanics is presented. A computer program Geo-Sim that can be used to perform virtual experiments, and allow for real-time observations of material response is presented. The results of experiments, for a given set of input parameters, are obtained with the test simulator using well-trained artificial neural-network-based soil models for different soil types and stress paths. Multimedia capabilities are integrated in Geo-Sim, using software that links and controls a laser disc player with a real-time parallel processing ability. During the simulation of a virtual experiment, relevant portions of the video image of a previously recorded test on an actual soil specimen are dispalyed along with the graphical presentation of response from the feedforward ANN model predictions. The pilot simulator developed to date includes all aspects related to performing a triaxial test on cohesionless soil under undrained and drained conditions. The benefits of the test simulator are also presented.
Dispersion of Response Times Reveals Cognitive Dynamics
ERIC Educational Resources Information Center
Holden, John G.; Van Orden, Guy C.; Turvey, Michael T.
2009-01-01
Trial-to-trial variation in word-pronunciation times exhibits 1/f scaling. One explanation is that human performances are consequent on multiplicative interactions among interdependent processes-interaction dominant dynamics. This article describes simulated distributions of pronunciation times in a further test for multiplicative interactions and…
Level of neurotic disorders among drivers causing traffic accidents.
Durić, Predrag; Filipović, Danka
2007-01-01
Different aspects of driver personality may affect traffic safety. Extended driver reaction time causes deceleration of the reflexes, which is a major cause of traffic accidents. Cornell index was used in 30 drivers responsible for traffic accidents, with the aim to measure their level of neurotic disorder and compare them with results of controls (drivers not responsible for traffic accidents). Reaction time was maesured and compared among subjects with normal results of Cornell test and those with pathological findings. Drivers causing traffic accidents showed significantly higher Cornell index scores than drivers not responsible for traffic accidents. Drivers with pathological results of Cornell index showed a significantly longer reaction time.
Experimental Evaluations of Selected Immersion Hypothermia Protection Equipment.
1979-10-12
Temperature Response ............... 30 Figure 1-3 Estimated Survival Times for Average Men ..... 49 Figure 1-4 Metabolic Rate Response :Subject BS...51 Figure 1-5 Metabolic Rate Response : Subject GE ............... 52 Figure 1-6 Selected Elementary Movements ............... 58 Figure 1-7 Fatigue... responses to cold-Immersion, while wearing the test articles, could be observed or-vs over a narrow range of body core temperatures Involving the mildest
Reflective-impulsive style and conceptual tempo in a gross motor task.
Keller, J; Ripoll, H
2001-06-01
The reflective-impulsive construct refers to responses made slowly or quickly in a situation with high uncertainty. Children who are labeled "reflective" take a longer time to respond and make few errors, whereas "impulsive" children are fast and inaccurate. Although the validity of the test and the definition of reflective-impulsive style are well accepted, whether such respond fast or slow to all tasks is questioned. Some children do not fit the dichotomy. Two other groups arise, the fast-accurate and the slow-inaccurate. The response styles of 86 boys, ages 5, 7, and 9 years performing a gross motor task, i.e., hitting a ball with a racquet, were studied. Analysis indicated that the slowest children on the Matching Familiar Figures Test can be faster than the fastest ones and remain more accurate. As the definition of the reflective-impulsive style is based on time, the reflective ones might better be viewed as children who can adapt the response time to the context and thus be more efficient at problem-solving.
Wopereis, Suzan; Stroeve, Johanna H M; Stafleu, Annette; Bakker, Gertruud C M; Burggraaf, Jacobus; van Erk, Marjan J; Pellis, Linette; Boessen, Ruud; Kardinaal, Alwine A F; van Ommen, Ben
2017-01-01
A key feature of metabolic health is the ability to adapt upon dietary perturbations. Recently, it was shown that metabolic challenge tests in combination with the new generation biomarkers allow the simultaneous quantification of major metabolic health processes. Currently, applied challenge tests are largely non-standardized. A systematic review defined an optimal nutritional challenge test, the "PhenFlex test" (PFT). This study aimed to prove that PFT modulates all relevant processes governing metabolic health thereby allowing to distinguish subjects with different metabolic health status. Therefore, 20 healthy and 20 type 2 diabetic (T2D) male subjects were challenged both by PFT and oral glucose tolerance test (OGTT). During the 8-h response time course, 132 parameters were quantified that report on 26 metabolic processes distributed over 7 organs (gut, liver, adipose, pancreas, vasculature, muscle, kidney) and systemic stress. In healthy subjects, 110 of the 132 parameters showed a time course response. Patients with T2D showed 18 parameters to be significantly different after overnight fasting compared to healthy subjects, while 58 parameters were different in the post-challenge time course after the PFT. This demonstrates the added value of PFT in distinguishing subjects with different health status. The OGTT and PFT response was highly comparable for glucose metabolism as identical amounts of glucose were present in both challenge tests. Yet the PFT reports on additional processes, including vasculature, systemic stress, and metabolic flexibility. The PFT enables the quantification of all relevant metabolic processes involved in maintaining or regaining homeostasis of metabolic health. Studying both healthy subjects and subjects with impaired metabolic health showed that the PFT revealed new processes laying underneath health. This study provides the first evidence towards adopting the PFT as gold standard in nutrition research.
Dynamic performance of MEMS deformable mirrors for use in an active/adaptive two-photon microscope
NASA Astrophysics Data System (ADS)
Zhang, Christian C.; Foster, Warren B.; Downey, Ryan D.; Arrasmith, Christopher L.; Dickensheets, David L.
2016-03-01
Active optics can facilitate two-photon microscopic imaging deep in tissue. We are investigating fast focus control mirrors used in concert with an aberration correction mirror to control the axial position of focus and system aberrations dynamically during scanning. With an adaptive training step, sample-induced aberrations may be compensated as well. If sufficiently fast and precise, active optics may be able to compensate under-corrected imaging optics as well as sample aberrations to maintain diffraction-limited performance throughout the field of view. Toward this end we have measured a Boston Micromachines Corporation Multi-DM 140 element deformable mirror, and a Revibro Optics electrostatic 4-zone focus control mirror to characterize dynamic performance. Tests for the Multi-DM included both step response and sinusoidal frequency sweeps of specific Zernike modes. For the step response we measured 10%-90% rise times for the target Zernike amplitude, and wavefront rms error settling times. Frequency sweeps identified the 3dB bandwidth of the mirror when attempting to follow a sinusoidal amplitude trajectory for a specific Zernike mode. For five tested Zernike modes (defocus, spherical aberration, coma, astigmatism and trefoil) we find error settling times for mode amplitudes up to 400nm to be less than 52 us, and 3 dB frequencies range from 6.5 kHz to 10 kHz. The Revibro Optics mirror was tested for step response only, with error settling time of 80 μs for a large 3 um defocus step, and settling time of only 18 μs for a 400nm spherical aberration step. These response speeds are sufficient for intra-scan correction at scan rates typical of two-photon microscopy.
Built-In Diagnostics (BID) Of Equipment/Systems
NASA Technical Reports Server (NTRS)
Granieri, Michael N.; Giordano, John P.; Nolan, Mary E.
1995-01-01
Diagnostician(TM)-on-Chip (DOC) technology identifies faults and commands systems reconfiguration. Smart microcontrollers operating in conjunction with other system-control circuits, command self-correcting system/equipment actions in real time. DOC microcontroller generates commands for associated built-in test equipment to stimulate unit of equipment diagnosed, collects and processes response data obtained by built-in test equipment, and performs diagnostic reasoning on response data, using diagnostic knowledge base derived from design data.
Saini, Devashish; Mazza, Giovanni; Shah, Najaf; Mirza, Muzna; Gori, Mandar M; Nandigam, Hari Krishna; Orthner, Helmuth F
2006-01-01
Response times for pre-hospital emergency care may be improved with the use of algorithms that analyzes historical patterns in incident location and suggests optimal places for prepositioning of emergency response units. We will develop such an algorithm based on cluster analysis and test whether it leads to significant improvement in mileage when compared to actual historical data of dispatching based on fixed stations. PMID:17238702
Saini, Devashish; Mazza, Giovanni; Shah, Najaf; Mirza, Muzna; Gori, Mandar M; Nandigam, Hari Krishna; Orthner, Helmuth F
2006-01-01
Response times for pre-hospital emergency care may be improved with the use of algorithms that analyzes historical patterns in incident location and suggests optimal places for pre-positioning of emergency response units. We will develop such an algorithm based on cluster analysis and test whether it leads to significant improvement in mileage when compared to actual historical data of dispatching based on fixed stations.
Boulet, Lindsey M; Tymko, Michael M; Jamieson, Alenna N; Ainslie, Philip N; Skow, Rachel J; Day, Trevor A
2016-07-01
What is the central question of this study? We characterized and compared the cardiorespiratory and cerebrovascular responses to the 'Duffin' modified hyperoxic CO2 rebreathing test by randomly altering the prior hyperventilation duration. What is the main finding and its importance? Our main finding was that prior hyperventilation duration (1, 3 or 5 min) had no effect on cardiorespiratory and cerebrovascular responses to the hyperoxic rebreathing test, within individuals. These findings suggest that the standard 5 min prior hyperventilation duration used to clear body CO2 stores is unnecessary and can reasonably be shortened to 1 min, reducing protocol times and improving participant comfort. The 'Duffin' modified hyperoxic rebreathing test allows investigators to characterize and quantify the ventilatory and cerebrovascular responses to CO2 across a large physiological range, allowing quantification of basal ventilation and the ventilatory recruitment threshold (VRT). Although the standard protocol includes 5 min of prior hyperventilation to clear body CO2 stores, there is no experimental evidence that a full 5 min is required. We hypothesized that there would be no within-individual differences in the cardiorespiratory or cerebrovascular responses to rebreathing with shortened hyperventilation duration prior to hyperoxic rebreathing. Using a rebreathing apparatus, transcranial Doppler ultrasound and beat-to-beat blood pressure monitoring, we tested 19 participants in the supine position using three randomly assigned hyperoxic rebreathing tests with 1, 3 or 5 min of prior hyperventilation. We measured VRT (in Torr CO2 ), time to VRT (in seconds), central respiratory chemoreflex (breathing frequency, tidal volume and minute ventilation), cerebrovascular (middle and posterior cerebral artery velocity) and cardiovascular (heart rate and mean arterial pressure) responses to CO2 during hyperoxic rebreathing. Using linear regression and repeated-measures ANOVAs, we found no differences in any of the cardiorespiratory or cerebrovascular response magnitudes between trials (P > 0.05). The only difference observed was in the time to VRT (in seconds), whereby 1 min prior hyperventilation duration was shorter (135.4 ± 19.7 s) than with 3 or 5 min prior hyperventilation (176.3 ± 15.1 and 187.2 ± 11.6 s, respectively; P < 0.001). Our findings indicate that 5 min of prior hyperventilation is unnecessary during modified rebreathing when using it to quantify respiratory or cerebrovascular responses and can be reasonably shortened to 1 min, reducing protocol times and improving participant comfort. © 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.
Effects of the antidepressant drug moclobemide on learning and memory in rats.
Getova, D; Dimitrova, D; Roukounakis, I
2003-12-01
Moclobemide is a well known drug with antidepressant action. The aim of this study was to investigate the effects of moclobemide on learning and memory processes in Sprague Dawley rats. Over a 5-day period, learning sessions with 30 trials per day and memory retention tests were performed. The conditioned responses (avoidances), the unconditioned responses (escapes) and the intertrial crossings were observed. An active avoidance test was carried out using a shuttle box. Two passive avoidance tests were used: step-through (using a light chamber) and step-down (using a platform). In the step-through passive avoidance test, the learning and retention sessions consisted of three trials each and the latency of reaction times (the rat remaining in the light chamber for more than 180 sec) was used as criterion. In the step-down passive avoidance test, learning and retention sessions consisted of two trials and the latency of reaction times (the rat remaining on the platform for 60 sec) was used as criterion. In the active avoidance tests, moclobemide dose-dependently increased the number of avoidances during learning sessions and maintained this number in memory retention tests. Moclobemide did not alter the number of escapes, but did increase motor activity. In the passive avoidance tests, moclobemide also increased the latency of reaction times in learning and short memory retrieval tests. These findings suggest that moclobemide improves learning and memory processes in active and passive avoidance tests and has a cognition-enhancing effect. (c) 2003 Prous Science
Dual channel photoplethysmography studies of cardio-vascular response to the body position changes
NASA Astrophysics Data System (ADS)
Erts, R.; Kukulis, I.; Spigulis, J.; Kere, L.
2005-08-01
The dual-channel photoplethysmography studies of physiological responses during 3-stage orthostatic test were performed. Clear differences in heartbeat rate, pulse wave transit time and blood pressure variations of healthy volunteers and diabetic patients have been observed.
Molecular Weight Effects on the Viscoelastic Response of a Polyimide
NASA Technical Reports Server (NTRS)
Nicholson, Lee M.; Whitley, Karen S.; Gates, Thomas S.
2000-01-01
The effect of molecular weight on the viscoelastic performance of an advanced polymer (LaRC -SI) was investigated through the use of creep compliance tests. Testing consisted of short-term isothermal creep and recovery with the creep segments performed under constant load. The tests were conducted at three temperatures below the glass transition temperature of each material with different molecular weight. Through the use of time-aging-time superposition procedures, the material constants, material master curves and aging-related parameters were evaluated at each temperature for a given molecular weight. The time-temperature superposition technique helped to describe the effect of temperature on the timescale of the viscoelastic response of each molecular weight. It was shown that the low molecular weight materials have increased creep compliance and creep compliance rate, and are more sensitive to temperature than the high molecular weight materials. Furthermore, a critical molecular weight transition was observed to occur at a weight-average molecular weight of approximately 25000 g/mol below which, the temperature sensitivity of the time-temperature superposition shift factor increases rapidly.
Measurements of speed of response of high-speed visible and IR optical detectors
NASA Technical Reports Server (NTRS)
Rowe, H. E.; Osmundson, J. S.
1972-01-01
A technique for measuring speed of response of high speed visible and IR optical detectors to mode-locked Nd:YAG laser pulses is described. Results of measurements of response times of four detectors are presented. Three detectors that can be used as receivers in a 500-MHz optical communication system are tested.
Hangar Fire Suppression Utilizing Novec 1230
2018-01-01
The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing...fuel fires in aircraft hangars. A 30×30×8-ft concrete-and-steel test structure was constructed for this test series . Four discharge assemblies...structure. System discharge parameters---discharge time , discharge rate, and quantity of agent discharged---were adjusted to produce the desired Novec 1230
Normalization methods in time series of platelet function assays
Van Poucke, Sven; Zhang, Zhongheng; Roest, Mark; Vukicevic, Milan; Beran, Maud; Lauwereins, Bart; Zheng, Ming-Hua; Henskens, Yvonne; Lancé, Marcus; Marcus, Abraham
2016-01-01
Abstract Platelet function can be quantitatively assessed by specific assays such as light-transmission aggregometry, multiple-electrode aggregometry measuring the response to adenosine diphosphate (ADP), arachidonic acid, collagen, and thrombin-receptor activating peptide and viscoelastic tests such as rotational thromboelastometry (ROTEM). The task of extracting meaningful statistical and clinical information from high-dimensional data spaces in temporal multivariate clinical data represented in multivariate time series is complex. Building insightful visualizations for multivariate time series demands adequate usage of normalization techniques. In this article, various methods for data normalization (z-transformation, range transformation, proportion transformation, and interquartile range) are presented and visualized discussing the most suited approach for platelet function data series. Normalization was calculated per assay (test) for all time points and per time point for all tests. Interquartile range, range transformation, and z-transformation demonstrated the correlation as calculated by the Spearman correlation test, when normalized per assay (test) for all time points. When normalizing per time point for all tests, no correlation could be abstracted from the charts as was the case when using all data as 1 dataset for normalization. PMID:27428217
NASA Technical Reports Server (NTRS)
DeLoach, Richard; Micol, John R.
2011-01-01
The factors that determine data volume requirements in a typical wind tunnel test are identified. It is suggested that productivity in wind tunnel testing can be enhanced by managing the inference error risk associated with evaluating residuals in a response surface modeling experiment. The relationship between minimum data volume requirements and the factors upon which they depend is described and certain simplifications to this relationship are realized when specific model adequacy criteria are adopted. The question of response model residual evaluation is treated and certain practical aspects of response surface modeling are considered, including inference subspace truncation. A wind tunnel test plan developed by using the Modern Design of Experiments illustrates the advantages of an early estimate of data volume requirements. Comparisons are made with a representative One Factor At a Time (OFAT) wind tunnel test matrix developed to evaluate a surface to air missile.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burton, G.A. Jr.
The use of traditional laboratory toxicity test species in field exposures have proven to be a valuable assessment tool for monitoring effluent, water, sediment and storm water quality. Mimicking fluctuating exposures of stressors with associated interactions with differing physico-chemical variables is difficult. In situ exposures are conducted for similar time periods measuring similar response endpoints as in more traditional laboratory tests. However, organisms are transferred to the field and exposed in various types of test chambers. The author has observed responses which are similar and which are significantly different from simultaneous laboratory exposures. Temperature, dissolved oxygen, suspended solids, natural light,more » flow, and predation may affect in situ responses, but are often removed from laboratory exposures. The strengths and weaknesses observed with these test systems over the past few years will be reviewed.« less
Cardiorespiratory response to exercise testing in individuals with Alzheimer's disease.
Billinger, Sandra A; Vidoni, Eric D; Honea, Robyn A; Burns, Jeffrey M
2011-12-01
To examine exercise testing response in Alzheimer's disease (AD) and possible disease-related change over time. Retrospective assessment of a 2-year observational study. University medical center. Individuals without dementia (n=50) and with AD (n=31). Not applicable. Participants underwent a clinical dementia evaluation and performed an incremental exercise test using a treadmill and the modified Bruce protocol at baseline and at a 2-year follow-up. We examined oxygen consumption, minute ventilation, heart rate, and ventilatory equivalents for oxygen and carbon dioxide at submaximal and peak exercise intensities to determine whether the measures were different between groups or over time. Participants with AD and those without dementia performed similarly at submaximal effort, and both groups showed similar changes in exercise response over 2 years. However, nondemented individuals had consistently higher values of oxygen consumption (P≤.02) and minute ventilation at peak effort at baseline (P=.003). Individuals with AD demonstrate physiologic responses to submaximal exercise effort that are not significantly different than individuals without dementia. However, differences are apparent at the extreme of effort. Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Rybacka-Mossakowska, J; Ramlau, R; Gazdulska, J; Gołda-Gocka, I; Kozubski, W; Michalak, S
2016-01-01
Cognitive impairment develops as a clinical manifestation of immune-mediated indirect effects of malignancy in lung cancer patients. This study aimed to evaluate the effects of humoral immune response on cognition in lung cancer patients. Fifty-one lung cancer patients were subjected to neurological examination: Mini Mental State Examination (MMSE), Trail Making Test (TMT), and Hamilton scale. The Psychology Experiment Building Language software was used for the evaluation of digit span, simple reaction time (SRT), and choice reaction time (CRT) tests. Serum samples were tested for the presence of onconeuronal antibodies and antineural antibodies. The results demonstrate that autoantibodies were found in 31 % patients. MMSE scores were lower (26.7 ± 2.7) in seropositive patients than in seronegative subjects (28.7 ± 1.2; p = 0.013). Executive functions were also influenced by the presence of autoantibodies. The humoral immune response in lung cancer patients affected both SRT and CRT. We conclude that the humoral immune response in lung cancer patients is associated with cognitive impairment. Cognitive impairment is associated with both specific reactions against onconeuronal or antineural antigens and non-organ specific reactions against nucleosome antigens.
OSL response bleaching of BeO samples, using fluorescent light and blue LEDs
NASA Astrophysics Data System (ADS)
Groppo, D. P.; Caldas, L. V. E.
2016-07-01
The optically stimulated luminescence (OSL) is widely used as a dosimetric technique for many applications. In this work, the OSL response bleaching of BeO samples was studied. The samples were irradiated using a beta radiation source (90Sr+90Y); the bleaching treatments (fluorescent light and blue LEDs) were performed, and the results were compared. Various optical treatment time intervals were tested until reaching the complete bleaching of the OSL response. The best combination of the time interval and bleaching type was analyzed.
Use of a Self-Instructional Radiographic Anatomy Module for Dental Hygiene Faculty Calibration.
Brame, Jennifer L; AlGheithy, Demah Salem; Platin, Enrique; Mitchell, Shannon H
2017-06-01
Purpose: Dental hygiene educators often provide inconsistent instruction in clinical settings and various attempts to address the lack of consistency have been reported in the literature. The purpose of this pilot study was to determine if the use of a use of a self-instructional, radiographic anatomy (SIRA) module improved DH faculty calibration regarding the identifica-tion of normal intraoral and extraoral radiographic anatomy and whether its effect could be sustained over a period of four months. Methods: A convenience sample consisting of all dental hygiene faculty members involved in clinical instruction (N=23) at the University of North Carolina (UNC) was invited to complete the four parts of this online pilot study: a pre-test, review of the SIRA module, an immediate post-test, and a four-month follow-up post-test. Descriptive analyses, the Friedman's ANOVA, and the exact form of the Wilcoxon-Signed-Rank test were used to an-alyze the data. Level of significance was set at 0.05. Participants who did not complete all parts of the study were omitted from data analysis comparing the pre to post-test performance. Results: The pre-test response rate was 73.9% (N=17), and 88.2% (N=15) of those initial participants completed both the immediate and follow-up post-tests. Faculty completing all parts of the study consisted of: 5 full-time faculty, 5 part-time faculty, and 5 graduate teaching assistants. The Friedman's ANOVA revealed no statistically significant difference (P=0.179) in percentages of correct responses between the three tests (pre, post and follow-up). The exact form of the Wilcoxon-Signed-Rank test revealed marginal significance when comparing percent of correct responses at pre-test and immediate post-test (P=0.054), and no statistically significant difference when comparing percent of correct responses at immediate post-test and the follow-up post-test four months later (P=0.106). Conclusions: Use of a SIRA module did not significantly affect DH faculty test performance. Lack of statistical significance in the percentages of correct responses between the three tests may have been affected by the small number of participants completing all four parts of the study (N=15). Additional research is needed to identify and improve methods for faculty calibration. Copyright © 2017 The American Dental Hygienists’ Association.
Cognitive Reflection, Decision Biases, and Response Times
Alós-Ferrer, Carlos; Garagnani, Michele; Hügelschäfer, Sabine
2016-01-01
We present novel evidence on response times and personality traits in standard questions from the decision-making literature where responses are relatively slow (medians around half a minute or above). To this end, we measured response times in a number of incentivized, framed items (decisions from description) including the Cognitive Reflection Test, two additional questions following the same logic, and a number of classic questions used to study decision biases in probability judgments (base-rate neglect, the conjunction fallacy, and the ratio bias). All questions create a conflict between an intuitive process and more deliberative thinking. For each item, we then created a non-conflict version by either making the intuitive impulse correct (resulting in an alignment question), shutting it down (creating a neutral question), or making it dominant (creating a heuristic question). For CRT questions, the differences in response times are as predicted by dual-process theories, with alignment and heuristic variants leading to faster responses and neutral questions to slower responses than the original, conflict questions. For decision biases (where responses are slower), evidence is mixed. To explore the possible influence of personality factors on both choices and response times, we used standard personality scales including the Rational-Experiential Inventory and the Big Five, and used them as controls in regression analysis. PMID:27713710
Cognitive Reflection, Decision Biases, and Response Times.
Alós-Ferrer, Carlos; Garagnani, Michele; Hügelschäfer, Sabine
2016-01-01
We present novel evidence on response times and personality traits in standard questions from the decision-making literature where responses are relatively slow (medians around half a minute or above). To this end, we measured response times in a number of incentivized, framed items (decisions from description) including the Cognitive Reflection Test, two additional questions following the same logic, and a number of classic questions used to study decision biases in probability judgments (base-rate neglect, the conjunction fallacy, and the ratio bias). All questions create a conflict between an intuitive process and more deliberative thinking. For each item, we then created a non-conflict version by either making the intuitive impulse correct (resulting in an alignment question), shutting it down (creating a neutral question), or making it dominant (creating a heuristic question). For CRT questions, the differences in response times are as predicted by dual-process theories, with alignment and heuristic variants leading to faster responses and neutral questions to slower responses than the original, conflict questions. For decision biases (where responses are slower), evidence is mixed. To explore the possible influence of personality factors on both choices and response times, we used standard personality scales including the Rational-Experiential Inventory and the Big Five, and used them as controls in regression analysis.
Association of Marijuana Use With Blunted Nucleus Accumbens Response to Reward Anticipation.
Martz, Meghan E; Trucco, Elisa M; Cope, Lora M; Hardee, Jillian E; Jester, Jennifer M; Zucker, Robert A; Heitzeg, Mary M
2016-08-01
Marijuana use may alter ventral striatal response to reward, which might heighten susceptibility to substance use disorder. Longitudinal research is needed to determine the effects of marijuana use on neural function involved in reward response. To determine whether marijuana use among young adults prospectively affects nucleus accumbens (NAcc) activation during reward anticipation. One hundred eight young adults were recruited from the Michigan Longitudinal Study, an ongoing study of youth at high risk for substance use disorder and a contrast sample of control families. Participants underwent 3 consecutive functional magnetic resonance imaging scans at approximate ages of 20 (time 1), 22 (time 2), and 24 (time 3) years. Self-report data on marijuana and other drug use occasions were collected annually since age 11 years. Cross-lagged models were used to test the association of marijuana use with neural response in the NAcc to reward anticipation during a monetary incentive delay task controlling for sex, age, other substance use, and family history of substance use disorder. Of 108 participants, 39 (36.1%) were female and mean (SD) age at baseline was 20.1 (1.4) years. Greater marijuana use was associated with later blunted activation in the NAcc during reward anticipation (time 1 to time 2: β = -0.26, P = .04; time 2 to time 3: β = -0.25, P = .01). When the cross-lagged model was tested with the inclusion of previous and concurrent cigarette use, the effect of marijuana use from time 2 to time 3 remained significant (β = -0.29; P = .005) and the effect of cigarette use was nonsignificant. The findings of this study indicate that marijuana use is associated with decreased neural response in the NAcc during the anticipation of nondrug rewards. Over time, marijuana use may alter anticipatory reward processing in the NAcc, which may increase the risk for continued drug use and later addiction.
Bergert, F Bryan; Nosofsky, Robert M
2007-01-01
The authors develop and test generalized versions of take-the-best (TTB) and rational (RAT) models of multiattribute paired-comparison inference. The generalized models make allowances for subjective attribute weighting, probabilistic orders of attribute inspection, and noisy decision making. A key new test involves a response-time (RT) approach. TTB predicts that RT is determined solely by the expected time required to locate the 1st discriminating attribute, whereas RAT predicts that RT is determined by the difference in summed evidence between the 2 alternatives. Critical test pairs are used that partially decouple these 2 factors. Under conditions in which ideal observer TTB and RAT strategies yield equivalent decisions, both the RT results and the estimated attribute weights suggest that the vast majority of subjects adopted the generalized TTB strategy. The RT approach is also validated in an experimental condition in which use of a RAT strategy is essentially forced upon subjects. (c) 2007 APA, all rights reserved.
Wilkins, Nicolas J; Rawson, Katherine A
2013-10-01
In Rickard, Lau, and Pashler's (2008) investigation of the lag effect on memory-based automaticity, response times were faster and proportion of trials retrieved was higher at the end of practice for short lag items than for long lag items. However, during testing after a delay, response times were slower and proportion of trials retrieved was lower for short lag items than for long lag items. The current study investigated the extent to which the lag effect on the durability of memory-based automaticity is due to interference or to the loss of memory strength with time. Participants repeatedly practiced alphabet subtraction items in short lag and long lag conditions. After practice, half of the participants were immediately tested and the other half were tested after a 7-day delay. Results indicate that the lag effect on the durability of memory-based automaticity is primarily due to interference. We discuss potential modification of current memory-based processing theories to account for these effects. © 2013.
Retarding field energy analyzer for high energy pulsed electron beam measurements.
Hu, Jing; Rovey, Joshua L; Zhao, Wansheng
2017-01-01
A retarding field energy analyzer (RFEA) designed specifically for high energy pulsed electron beam measurements is described in this work. By proper design of the entrance grid, attenuation grid, and beam collector, this RFEA is capable of determining the time-resolved energy distribution of high energy pulsed electron beams normally generated under "soft vacuum" environment. The performance of the RFEA is validated by multiple tests of the leakage current, attenuation coefficient, and response time. The test results show that the retarding potential in the RFEA can go up to the same voltage as the electron beam source, which is 20 kV for the maximum in this work. Additionally, an attenuation coefficient of 4.2 is obtained in the RFEA while the percent difference of the rise time of the electron beam pulse before and after attenuation is lower than 10%. When compared with a reference source, the percent difference of the RFEA response time is less than 10% for fall times greater than 35 ns. Finally, the test results of the 10 kV pseudospark-based pulsed electron beam currents collected under varying retarding potentials are presented in this paper.
Quality improvement utilizing in-situ simulation for a dual-hospital pediatric code response team.
Yager, Phoebe; Collins, Corey; Blais, Carlene; O'Connor, Kathy; Donovan, Patricia; Martinez, Maureen; Cummings, Brian; Hartnick, Christopher; Noviski, Natan
2016-09-01
Given the rarity of in-hospital pediatric emergency events, identification of gaps and inefficiencies in the code response can be difficult. In-situ, simulation-based medical education programs can identify unrecognized systems-based challenges. We hypothesized that developing an in-situ, simulation-based pediatric emergency response program would identify latent inefficiencies in a complex, dual-hospital pediatric code response system and allow rapid intervention testing to improve performance before implementation at an institutional level. Pediatric leadership from two hospitals with a shared pediatric code response team employed the Institute for Healthcare Improvement's (IHI) Breakthrough Model for Collaborative Improvement to design a program consisting of Plan-Do-Study-Act cycles occurring in a simulated environment. The objectives of the program were to 1) identify inefficiencies in our pediatric code response; 2) correlate to current workflow; 3) employ an iterative process to test quality improvement interventions in a safe environment; and 4) measure performance before actual implementation at the institutional level. Twelve dual-hospital, in-situ, simulated, pediatric emergencies occurred over one year. The initial simulated event allowed identification of inefficiencies including delayed provider response, delayed initiation of cardiopulmonary resuscitation (CPR), and delayed vascular access. These gaps were linked to process issues including unreliable code pager activation, slow elevator response, and lack of responder familiarity with layout and contents of code cart. From first to last simulation with multiple simulated process improvements, code response time for secondary providers coming from the second hospital decreased from 29 to 7 min, time to CPR initiation decreased from 90 to 15 s, and vascular access obtainment decreased from 15 to 3 min. Some of these simulated process improvements were adopted into the institutional response while others continue to be trended over time for evidence that observed changes represent a true new state of control. Utilizing the IHI's Breakthrough Model, we developed a simulation-based program to 1) successfully identify gaps and inefficiencies in a complex, dual-hospital, pediatric code response system and 2) provide an environment in which to safely test quality improvement interventions before institutional dissemination. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Collecting and Applying Usability Data from Distance Learners
ERIC Educational Resources Information Center
Mitchell, Emily; West, Brandon
2017-01-01
Growth of their college's off-campus and online course offerings led librarians at SUNY Oswego to run usability tests with off-campus students to compensate for a lack of responses from this population during earlier usability testing. Constraints on testing with off-campus students included lack of funding and librarian time, as well as…
Evaluation of ride quality measurement procedures by subjective experiments using simulators
NASA Technical Reports Server (NTRS)
Klauder, L. T., Jr.; Clevenson, S. A.
1975-01-01
Since ride quality is, by definition, a matter of passenger response, there is need for a qualification procedure (QP) for establishing the degree to which any particular ride quality measurement procedure (RQMP) does correlate with passenger responses. Once established, such a QP will provide very useful guidance for optimal adjustment of the various parameters which any given RQMP contains. A QP is proposed based on use of a ride motion simulator and on test subject responses to recordings of actual vehicle motions. Test subject responses are used to determine simulator gain settings for the individual recordings such as to make all of the simulated rides equally uncomfortable to the test subjects. Simulator platform accelerations vs. time are recorded with each ride at its equal discomfort gain setting. The equal discomfort platform acceleration recordings are then digitzed.
Arneja, Jugpal S; Narasimhan, Kailash; Bouwman, David; Bridge, Patrick D
2009-12-01
In-training evaluations in graduate medical education have typically been challenging. Although the majority of standardized examination delivery methods have become computer-based, in-training examinations generally remain pencil-paper-based, if they are performed at all. Audience response systems present a novel way to stimulate and evaluate the resident-learner. The purpose of this study was to assess the outcomes of audience response systems testing as compared with traditional testing in a plastic surgery residency program. A prospective 1-year pilot study of 10 plastic surgery residents was performed using audience response systems-delivered testing for the first half of the academic year and traditional pencil-paper testing for the second half. Examination content was based on monthly "Core Quest" curriculum conferences. Quantitative outcome measures included comparison of pretest and posttest and cumulative test scores of both formats. Qualitative outcomes from the individual participants were obtained by questionnaire. When using the audience response systems format, pretest and posttest mean scores were 67.5 and 82.5 percent, respectively; using traditional pencil-paper format, scores were 56.5 percent and 79.5 percent. A comparison of the cumulative mean audience response systems score (85.0 percent) and traditional pencil-paper score (75.0 percent) revealed statistically significantly higher scores with audience response systems (p = 0.01). Qualitative outcomes revealed increased conference enthusiasm, greater enjoyment of testing, and no user difficulties with the audience response systems technology. The audience response systems modality of in-training evaluation captures participant interest and reinforces material more effectively than traditional pencil-paper testing does. The advantages include a more interactive learning environment, stimulation of class participation, immediate feedback to residents, and immediate tabulation of results for the educator. Disadvantages include start-up costs and lead-time preparation.
ERIC Educational Resources Information Center
Schroeders, Ulrich; Robitzsch, Alexander; Schipolowski, Stefan
2014-01-01
C-tests are a specific variant of cloze tests that are considered time-efficient, valid indicators of general language proficiency. They are commonly analyzed with models of item response theory assuming local item independence. In this article we estimated local interdependencies for 12 C-tests and compared the changes in item difficulties,…
Guarascio-Howard, Linda
2011-01-01
A medical-surgical unit in a southwestern United States hospital examined the results of adding wireless communication technology to assist nurses in identifying patient bed status changes and enhancing team communication. Following the addition of wireless communication, response time to patient calls and the number of nurse-initiated communications were compared to pre-wireless calls and response time sampling period. In the baseline study, nurse-initiated communications and response time to patient calls were investigated for a team nursing model (Guarascio-Howard & Malloch, 2007). At this time, technology consisted of a nurse call system and telephones located at each decentralized nurse station and health unit coordinator (HUC) station. For this follow-up study, a wireless device was given to nurses and their team members following training on device use and privacy issues. Four registered nurses (RNs) were shadowed for 8 hours (32 hours total) before and after the introduction of the wireless devices. Data were collected regarding patient room visits, number of patient calls, bed status calls, response time to calls, and the initiator of the communication episodes. Follow-up study response time to calls significantly decreased (t-test p = .03). RNs and licensed practical nurses responded to bed status calls in less than 1 minute-62% of the 37 calls. Communication results indicated a significant shift (One Proportion Z Test) in RN-initiated communications, suggesting an enhanced ability to communicate with team members and to assist in monitoring patient status. Patient falls trended downward, although not significantly (p > .05), for a 6-month period of wireless technology use compared to the same period the previous year. The addition of a wireless device has advantages in team nursing, namely increasing communication with staff members and decreasing response time to patient and bed status calls. Limitations of the study included a change in caregiver team members and issues regarding wireless device and locator badge compliance. Administrative issues that arose during this field study included bed and cable maintenance, device battery charging, and the training of new and floating team members.
A novel structure of transmission line pulse transformer with mutually coupled windings.
Yu, Binxiong; Su, Jiancang; Li, Rui; Zhao, Liang; Zhang, Xibo; Wang, Junjie
2014-03-01
A novel structure of transmission line transformer (TLT) with mutually coupled windings is described in this paper. All transmission lines except the first stage of the transformer are wound on a common ferrite core for the TLT with this structure. A referral method was introduced to analyze the TLT with this structure, and an analytic expression of the step response was derived. It is shown that a TLT with this structure has a significantly slower droop rate than a TLT with other winding structures and the number of ferrite cores needed is largely reduced. A four-stage TLT with this structure was developed, whose input and output impedance were 4.2 Ω and 67.7 Ω, respectively. A frequency response test of the TLT was carried out. The test results showed that pulse response time of the TLT is several nanoseconds. The TLT described in this paper has the potential to be used as a rectangle pulse transformer with very fast response time.
ERIC Educational Resources Information Center
Bookard, Katina L.
2014-01-01
The purpose of this correlational study was to test to see if there was a relationship between time reduction of the roles and responsibilities of a school counselor and the Response to Intervention (RTI) process in an elementary school setting. This study examined the perceived effects of the RTI process on the roles and responsibilities of a…
Gulati, Abhishek; Faed, James M; Isbister, Geoffrey K; Duffull, Stephen B
2015-10-01
Dosing of enoxaparin, like other anticoagulants, may result in bleeding following excessive doses and clot formation if the dose is too low. We recently showed that a factor Xa based clotting time test could potentially assess the effect of enoxaparin on the clotting system. However, the test did not perform well in subsequent individuals and effectiveness of an exogenous phospholipid, Actin FS, in reducing the variability in the clotting time was assessed. The aim of this work was to conduct an adaptive pilot study to determine the range of concentrations of Xa and Actin FS to take forward into a proof-of-concept study. A nonlinear parametric function was developed to describe the response surface over the factors of interest. An adaptive method was used to estimate the parameters using a D-optimal design criterion. In order to provide a reasonable probability of observing a success of the clotting time test, a P-optimal design criterion was incorporated using a loss function to describe the hybrid DP-optimality. The use of adaptive DP-optimality method resulted in an efficient estimation of model parameters using data from only 6 healthy volunteers. The use of response surface modelling identified a range of sets of Xa and Actin FS concentrations, any of which could be used for the proof-of-concept study. This study shows that parsimonious adaptive DP-optimal designs may provide both precise parameter estimates for response surface modelling as well as clinical confidence in the potential benefits of the study.
Batenburg, Anika; Das, Enny
2014-01-01
How can we best support others in difficult times? Studies testing the effects of supportive communication revealed mixed findings. The current study focuses on the effects of supportive communication following different disclosure styles, and includes outcome measures to assess emotional well-being. Hypotheses were tested in a 2 (disclosure style: cognitive reappraisal disclosure vs. emotional disclosure) ×3 (support message: cognitive reappraisal response vs. socio-affective response vs. no response) between subjects factorial design. Receiving a cognitive reappraisal response, rather than a socio-affective response or no response, decreased emotional distress in the emotional disclosure group. Support messages showed no effects in the cognitive reappraisal disclosure group. Although socio-affective responses were positively evaluated, cognitive reappraisal responses may be more effective during emotional upheaval because they provide a positive way out of negative emotions. PMID:25531509
Cheetham, Tara J; Turner-Cobb, Julie M
2016-01-01
Whilst acute stress paradigms in adults make use of adult panel members, similar paradigms modified for child participants have not manipulated the panel. Most work has utilised an audience of adult confederates, regardless of the age of the population being tested. The aim of this study was to trial a social stress test for children that provided a meaningful environment using age-matched child peers as panel actors. Thirty-three participants (7-11 years) underwent the Bath Experimental Stress Test for Children (BEST-C). Based on the Trier Social Stress Test (TSST), it comprises a shortened six-minute public speaking task and four-minute maths challenge. It differs from previous stress tests by using age-matched children on the panel, pre-recorded and presented as a live feed, and includes an expanded manipulation check of subjective experience. Salivary cortisol was assessed at four time points, pre-post stress testing; life events, daily hassles and coping strategies were measured through questionnaires. A simple numerical coding scheme was applied to post-test interview data. The BEST-C generated a typical stress and adaptation response in salivary cortisol (p=.032). Age and gender differences were observed during recovery. Cortisol responses mapped directly onto three distinct subjective response patterns: (i) expected response and recovery; (ii) expected response, no recovery; (iii) no response. The BEST-C, utilising child confederates of participant target age is a meaningful social stress test for children. This is the first social stress test developed specifically for children that manipulates panel characteristics by using child confederates and a pre-recorded sham panel. Greater cortisol responses to the test were also found to match subjective verbal accounts of the experience. It offers a meaningful acute stress paradigm with potential applications to other child and adolescent age groups. Furthermore, it leads the way in the use of panel manipulation in social stress testing. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Granaas, Michael M.; Rhea, Donald C.
1989-01-01
The requirements for the development of real-time displays are reviewed. Of particular interest are the psychological aspects of design such as the layout, color selection, real-time response rate, and the interactivity of displays. Some existing Western Aeronautical Test Range displays are analyzed.
Aspects of Motor Performance and Preacademic Learning.
ERIC Educational Resources Information Center
Feder, Katya; Kerr, Robert
1996-01-01
The Miller Assessment for Preschoolers (MAP) and a number/counting test were given to 50 4- and 5-year-olds. Low performance on counting was related to significantly slower average response time, overshoot movement time, and reaction time, indicating perceptual-motor difficulty. Low MAP scores indicated difficulty processing visual spatial…
High Fidelity Thermal Simulators for Non-Nuclear Testing: Analysis and Initial Results
NASA Technical Reports Server (NTRS)
Bragg-Sitton, Shannon M.; Dickens, Ricky; Dixon, David
2007-01-01
Non-nuclear testing can be a valuable tool in the development of a space nuclear power system, providing system characterization data and allowing one to work through various fabrication, assembly and integration issues without the cost and time associated with a full ground nuclear test. In a non-nuclear test bed, electric heaters are used to simulate the heat from nuclear fuel. Testing with non-optimized heater elements allows one to assess thermal, heat transfer, and stress related attributes of a given system, but fails to demonstrate the dynamic response that would be present in an integrated, fueled reactor system. High fidelity thermal simulators that match both the static and the dynamic fuel pin performance that would be observed in an operating, fueled nuclear reactor can vastly increase the value of non-nuclear test results. With optimized simulators, the integration of thermal hydraulic hardware tests with simulated neutronie response provides a bridge between electrically heated testing and fueled nuclear testing, providing a better assessment of system integration issues, characterization of integrated system response times and response characteristics, and assessment of potential design improvements' at a relatively small fiscal investment. Initial conceptual thermal simulator designs are determined by simple one-dimensional analysis at a single axial location and at steady state conditions; feasible concepts are then input into a detailed three-dimensional model for comparison to expected fuel pin performance. Static and dynamic fuel pin performance for a proposed reactor design is determined using SINDA/FLUINT thermal analysis software, and comparison is made between the expected nuclear performance and the performance of conceptual thermal simulator designs. Through a series of iterative analyses, a conceptual high fidelity design can developed. Test results presented in this paper correspond to a "first cut" simulator design for a potential liquid metal (NaK) cooled reactor design that could be applied for Lunar surface power. Proposed refinements to this simulator design are also presented.
Validation of Clinical Testing for Warfarin Sensitivity
Langley, Michael R.; Booker, Jessica K.; Evans, James P.; McLeod, Howard L.; Weck, Karen E.
2009-01-01
Responses to warfarin (Coumadin) anticoagulation therapy are affected by genetic variability in both the CYP2C9 and VKORC1 genes. Validation of pharmacogenetic testing for warfarin responses includes demonstration of analytical validity of testing platforms and of the clinical validity of testing. We compared four platforms for determining the relevant single nucleotide polymorphisms (SNPs) in both CYP2C9 and VKORC1 that are associated with warfarin sensitivity (Third Wave Invader Plus, ParagonDx/Cepheid Smart Cycler, Idaho Technology LightCycler, and AutoGenomics Infiniti). Each method was examined for accuracy, cost, and turnaround time. All genotyping methods demonstrated greater than 95% accuracy for identifying the relevant SNPs (CYP2C9 *2 and *3; VKORC1 −1639 or 1173). The ParagonDx and Idaho Technology assays had the shortest turnaround and hands-on times. The Third Wave assay was readily scalable to higher test volumes but had the longest hands-on time. The AutoGenomics assay interrogated the largest number of SNPs but had the longest turnaround time. Four published warfarin-dosing algorithms (Washington University, UCSF, Louisville, and Newcastle) were compared for accuracy for predicting warfarin dose in a retrospective analysis of a local patient population on long-term, stable warfarin therapy. The predicted doses from both the Washington University and UCSF algorithms demonstrated the best correlation with actual warfarin doses. PMID:19324988
Langley, Michael R; Booker, Jessica K; Evans, James P; McLeod, Howard L; Weck, Karen E
2009-05-01
Responses to warfarin (Coumadin) anticoagulation therapy are affected by genetic variability in both the CYP2C9 and VKORC1 genes. Validation of pharmacogenetic testing for warfarin responses includes demonstration of analytical validity of testing platforms and of the clinical validity of testing. We compared four platforms for determining the relevant single nucleotide polymorphisms (SNPs) in both CYP2C9 and VKORC1 that are associated with warfarin sensitivity (Third Wave Invader Plus, ParagonDx/Cepheid Smart Cycler, Idaho Technology LightCycler, and AutoGenomics Infiniti). Each method was examined for accuracy, cost, and turnaround time. All genotyping methods demonstrated greater than 95% accuracy for identifying the relevant SNPs (CYP2C9 *2 and *3; VKORC1 -1639 or 1173). The ParagonDx and Idaho Technology assays had the shortest turnaround and hands-on times. The Third Wave assay was readily scalable to higher test volumes but had the longest hands-on time. The AutoGenomics assay interrogated the largest number of SNPs but had the longest turnaround time. Four published warfarin-dosing algorithms (Washington University, UCSF, Louisville, and Newcastle) were compared for accuracy for predicting warfarin dose in a retrospective analysis of a local patient population on long-term, stable warfarin therapy. The predicted doses from both the Washington University and UCSF algorithms demonstrated the best correlation with actual warfarin doses.
Arantes, Joana
2008-06-01
The present research tested the generality of the "context effect" previously reported in experiments using temporal double bisection tasks [e.g., Arantes, J., Machado, A. Context effects in a temporal discrimination task: Further tests of the Scalar Expectancy Theory and Learning-to-Time models. J. Exp. Anal. Behav., in press]. Pigeons learned two temporal discriminations in which all the stimuli appear successively: 1s (red) vs. 4s (green) and 4s (blue) vs. 16s (yellow). Then, two tests were conducted to compare predictions of two timing models, Scalar Expectancy Theory (SET) and the Learning-to-Time (LeT) model. In one test, two psychometric functions were obtained by presenting pigeons with intermediate signal durations (1-4s and 4-16s). Results were mixed. In the critical test, pigeons were exposed to signals ranging from 1 to 16s and followed by the green or the blue key. Whereas SET predicted that the relative response rate to each of these keys should be independent of the signal duration, LeT predicted that the relative response rate to the green key (compared with the blue key) should increase with the signal duration. Results were consistent with LeT's predictions, showing that the context effect is obtained even when subjects do not need to make a choice between two keys presented simultaneously.
NASA Technical Reports Server (NTRS)
Lamarr, Michael; Chinske, Chris; Williams, Ethan; Law, Cameron; Skoog, Mark; Sorokowski, Paul
2016-01-01
The NASA improved Ground Collision Avoidance System (iGCAS) team conducted an onsite usability study at Experimental Aircraft Association (EAA) Air Venture in Oshkosh, Wisconsin from July 19 through July 26, 2015. EAA Air Venture had approximately 550,000 attendees from which the sample pool of pilots were selected. The objectives of this study were to assess the overall appropriateness and acceptability of iGCAS as a warning system for General Aviation aircraft, usability of the iGCAS displays and audio cues, test terrain avoidance characteristics, performance, functionality, pilot response time, and correlate terrain avoidance performance and pilot response time data.
Sung, Kyongje
2008-12-01
Participants searched a visual display for a target among distractors. Each of 3 experiments tested a condition proposed to require attention and for which certain models propose a serial search. Serial versus parallel processing was tested by examining effects on response time means and cumulative distribution functions. In 2 conditions, the results suggested parallel rather than serial processing, even though the tasks produced significant set-size effects. Serial processing was produced only in a condition with a difficult discrimination and a very large set-size effect. The results support C. Bundesen's (1990) claim that an extreme set-size effect leads to serial processing. Implications for parallel models of visual selection are discussed.
A mercury flow meter for ion thruster testing. [response time, thermal sensitivity
NASA Technical Reports Server (NTRS)
Wilbur, P. J.
1973-01-01
The theory of operation of the thermal flow meter is presented, and a theoretical model is used to determine design parameters for a device capable of measuring mercury flows in the range of 0 to 5 gm/hr. Flow meter construction is described. Tests performed using a positive displacement mercury pump as well as those performed with the device in the feed line of an operating thruster are discussed. A flow meter response time of about a minute and a sensitivity of about 10 mv/gm/hr are demonstrated. Additional work to relieve a sensitivity of the device to variations in ambient temperature is indicated to improve its quantitative performance.
NASA Technical Reports Server (NTRS)
Doggett, William; Vazquez, Sixto
2000-01-01
A visualization system is being developed out of the need to monitor, interpret, and make decisions based on the information from several thousand sensors during experimental testing to facilitate development and validation of structural health monitoring algorithms. As an added benefit the system will enable complete real-time sensor assessment of complex test specimens. Complex structural specimens are routinely tested that have hundreds or thousands of sensors. During a test, it is impossible for a single researcher to effectively monitor all the sensors and subsequently interesting phenomena occur that are not recognized until post-test analysis. The ability to detect and alert the researcher to these unexpected phenomena as the test progresses will significantly enhance the understanding and utilization of complex test articles. Utilization is increased by the ability to halt a test when the health monitoring algorithm response is not satisfactory or when an unexpected phenomenon occurs, enabling focused investigation potentially through the installation of additional sensors. Often if the test continues, structural changes make it impossible to reproduce the conditions that exhibited the phenomena. The prohibitive time and costs associated with fabrication, sensoring, and subsequent testing of additional test articles generally makes it impossible to further investigate the phenomena. A scalable architecture is described to address the complex computational demands of structural health monitoring algorithm development and laboratory experimental test monitoring. The researcher monitors the test using a photographic quality 3D graphical model with actual sensor locations identified. In addition, researchers can quickly activate plots displaying time or load versus selected sensor response along with the expected values and predefined limits. The architecture has several key features. First, distributed dissimilar computers may be seamlessly integrated into the information flow. Second, virtual sensors may be defined that are complex functions of existing sensors or other virtual sensors. Virtual sensors represent a calculated value not directly measured by particular physical instrument. They can be used, for example, to represent the maximum difference in a range of sensors or the calculated buckling load based on the current strains. Third, the architecture enables autonomous response to preconceived events, where by the system can be configured to suspend or abort a test if a failure is detected in the load introduction system. Fourth, the architecture is designed to allow cooperative monitoring and control of the test progression from multiple stations both remote and local to the test system. To illustrate the architecture, a preliminary implementation is described monitoring the Stitched Composite Wing recently tested at LaRC.
Espinosa, Enrique; Calderas, Tania; Flores-Muciño, Oscar; Pérez-García, Georgina; Vázquez-Camacho, Ana C; Bermúdez-Rattoni, Federico
2004-01-01
New research in conditioned enhancement of antibody response requires a general paradigm effective with different antigens. In this experiment series we applied a one-trial protocol using keyhole limpet hemocyanin immunization as an unconditioned stimulus. Several different conditions were tested. Two different times between conditioning and test trial, two relevant antigen doses and the use of an antigen booster during test trial were investigated. We did not find a conditioned effect in any of the conditions used. In contrast, we found a reliable albeit modest conditioned effect using hen egg lysozyme as unconditioned stimulus. By comparing these and other findings we conclude that the number of conditioning trials is a possible requirement for a more reliable conditioning of antibody response.
Germline APC mutations in hepatoblastoma.
Yang, Adeline; Sisson, Rebecca; Gupta, Anita; Tiao, Greg; Geller, James I
2018-04-01
Conflicting reports on the frequency of germline adenomatous polyposis coli (APC) gene mutations in patients with hepatoblastoma (HB) have called into question the clinical value of APC mutation testing on apparently sporadic HB. An Institutional Review Board approved retrospective review of clinical data collected from patients with HB who received APC testing at our institution was conducted. All HB patients seen at Cincinnati Children's Hospital Medical Center were eligible for testing. Potential genotype/phenotype correlations were assessed. As of July 2015, 29 patients with HB had received constitutional APC testing. Four (14%) were found to have APC pathogenic truncations of the APC protein and in addition two (7%) had APC missense variants of unknown clinical significance. Two patients (7%) had family histories indicative of familial adenomatous polyposis (FAP). Response to chemotherapy tracked differently in APC pathogenic cases, with a slower imaging response despite an equivalent or slightly faster α-fetoprotein (AFP) response. The prevalence of pathogenic APC variants in apparently sporadic HB may be higher than previously detected. Differences in time to imaging response, despite similar AFP response, may impact surgical planning. All patients with HB warrant germline APC mutation testing for underlying FAP. © 2017 Wiley Periodicals, Inc.
Using Combined Diagnostic Test Results to Hindcast Trends of Infection from Cross-Sectional Data
Rydevik, Gustaf; Innocent, Giles T.; Marion, Glenn; White, Piran C. L.; Billinis, Charalambos; Barrow, Paul; Mertens, Peter P. C.; Gavier-Widén, Dolores; Hutchings, Michael R.
2016-01-01
Infectious disease surveillance is key to limiting the consequences from infectious pathogens and maintaining animal and public health. Following the detection of a disease outbreak, a response in proportion to the severity of the outbreak is required. It is thus critical to obtain accurate information concerning the origin of the outbreak and its forward trajectory. However, there is often a lack of situational awareness that may lead to over- or under-reaction. There is a widening range of tests available for detecting pathogens, with typically different temporal characteristics, e.g. in terms of when peak test response occurs relative to time of exposure. We have developed a statistical framework that combines response level data from multiple diagnostic tests and is able to ‘hindcast’ (infer the historical trend of) an infectious disease epidemic. Assuming diagnostic test data from a cross-sectional sample of individuals infected with a pathogen during an outbreak, we use a Bayesian Markov Chain Monte Carlo (MCMC) approach to estimate time of exposure, and the overall epidemic trend in the population prior to the time of sampling. We evaluate the performance of this statistical framework on simulated data from epidemic trend curves and show that we can recover the parameter values of those trends. We also apply the framework to epidemic trend curves taken from two historical outbreaks: a bluetongue outbreak in cattle, and a whooping cough outbreak in humans. Together, these results show that hindcasting can estimate the time since infection for individuals and provide accurate estimates of epidemic trends, and can be used to distinguish whether an outbreak is increasing or past its peak. We conclude that if temporal characteristics of diagnostics are known, it is possible to recover epidemic trends of both human and animal pathogens from cross-sectional data collected at a single point in time. PMID:27384712
Theoretical frameworks for testing relativistic gravity: A review
NASA Technical Reports Server (NTRS)
Thorne, K. S.; Will, C. M.; Ni, W.
1971-01-01
Metric theories of gravity are presented, including the definition of metric theory, evidence for its existence, and response of matter to gravity with test body trajectories, gravitational red shift, and stressed matter responses. Parametrized post-Newtonian framework and interpretations are reviewed. Gamma, beta and gamma, and varied other parameters were measured. Deflection of electromagnetic waves, radar time delay, geodetic gyroscope precession, perihelion shifts, and periodic effects in orbits are among various studies carried out for metric theory experimentation.
Analysis of Accelerometer Data from a Woven Inflatable Creep Burst Test
NASA Technical Reports Server (NTRS)
James, George H.; Grygier, Michael; Selig, Molly M.
2015-01-01
Accelerometers were used to montor an inflatable test article during a creep test to failure. The test article experienced impulse events that were classified based on the response of the sensors and their time-dependent manifestation. These impulse events required specialized techniques to process the structural dynamics data. However, certain phenomena were defined as worthy of additional study. An assessment of one phenomena (a frequency near 1000Hz) showed a time dependent frequency and an amplitude that increased significantly near the end of the test. Hence, these observations are expected to drive future understanding of and utility in inflatable space structures.
Speed accuracy trade-off under response deadlines
Karşılar, Hakan; Simen, Patrick; Papadakis, Samantha; Balcı, Fuat
2014-01-01
Perceptual decision making has been successfully modeled as a process of evidence accumulation up to a threshold. In order to maximize the rewards earned for correct responses in tasks with response deadlines, participants should collapse decision thresholds dynamically during each trial so that a decision is reached before the deadline. This strategy ensures on-time responding, though at the cost of reduced accuracy, since slower decisions are based on lower thresholds and less net evidence later in a trial (compared to a constant threshold). Frazier and Yu (2008) showed that the normative rate of threshold reduction depends on deadline delays and on participants' uncertainty about these delays. Participants should start collapsing decision thresholds earlier when making decisions under shorter deadlines (for a given level of timing uncertainty) or when timing uncertainty is higher (for a given deadline). We tested these predictions using human participants in a random dot motion discrimination task. Each participant was tested in free-response, short deadline (800 ms), and long deadline conditions (1000 ms). Contrary to optimal-performance predictions, the resulting empirical function relating accuracy to response time (RT) in deadline conditions did not decline to chance level near the deadline; nor did the slight decline we typically observed relate to measures of endogenous timing uncertainty. Further, although this function did decline slightly with increasing RT, the decline was explainable by the best-fitting parameterization of Ratcliff's diffusion model (Ratcliff, 1978), whose parameters are constant within trials. Our findings suggest that at the very least, typical decision durations are too short for participants to adapt decision parameters within trials. PMID:25177265
Use of Lean response to improve pandemic influenza surge in public health laboratories.
Isaac-Renton, Judith L; Chang, Yin; Prystajecky, Natalie; Petric, Martin; Mak, Annie; Abbott, Brendan; Paris, Benjamin; Decker, K C; Pittenger, Lauren; Guercio, Steven; Stott, Jeff; Miller, Joseph D
2012-01-01
A novel influenza A (H1N1) virus detected in April 2009 rapidly spread around the world. North American provincial and state laboratories have well-defined roles and responsibilities, including providing accurate, timely test results for patients and information for regional public health and other decision makers. We used the multidisciplinary response and rapid implementation of process changes based on Lean methods at the provincial public health laboratory in British Columbia, Canada, to improve laboratory surge capacity in the 2009 influenza pandemic. Observed and computer simulating evaluation results from rapid processes changes showed that use of Lean tools successfully expanded surge capacity, which enabled response to the 10-fold increase in testing demands.
In Vitro Evaluation of Fluorescence Glucose Biosensor Response
Aloraefy, Mamdouh; Pfefer, T. Joshua; Ramella-Roman, Jessica C.; Sapsford, Kim E.
2014-01-01
Rapid, accurate, and minimally-invasive glucose biosensors based on Förster Resonance Energy Transfer (FRET) for glucose measurement have the potential to enhance diabetes control. However, a standard set of in vitro approaches for evaluating optical glucose biosensor response under controlled conditions would facilitate technological innovation and clinical translation. Towards this end, we have identified key characteristics and response test methods, fabricated FRET-based glucose biosensors, and characterized biosensor performance using these test methods. The biosensors were based on competitive binding between dextran and glucose to concanavalin A and incorporated long-wavelength fluorescence dye pairs. Testing characteristics included spectral response, linearity, sensitivity, limit of detection, kinetic response, reversibility, stability, precision, and accuracy. The biosensor demonstrated a fluorescence change of 45% in the presence of 400 mg/dL glucose, a mean absolute relative difference of less than 11%, a limit of detection of 25 mg/dL, a response time of 15 min, and a decay in fluorescence intensity of 72% over 30 days. The battery of tests presented here for objective, quantitative in vitro evaluation of FRET glucose biosensors performance have the potential to form the basis of future consensus standards. By implementing these test methods for a long-visible-wavelength biosensor, we were able to demonstrate strengths and weaknesses with a new level of thoroughness and rigor. PMID:25006996
In vitro evaluation of fluorescence glucose biosensor response.
Aloraefy, Mamdouh; Pfefer, T Joshua; Ramella-Roman, Jessica C; Sapsford, Kim E
2014-07-08
Rapid, accurate, and minimally-invasive glucose biosensors based on Förster Resonance Energy Transfer (FRET) for glucose measurement have the potential to enhance diabetes control. However, a standard set of in vitro approaches for evaluating optical glucose biosensor response under controlled conditions would facilitate technological innovation and clinical translation. Towards this end, we have identified key characteristics and response test methods, fabricated FRET-based glucose biosensors, and characterized biosensor performance using these test methods. The biosensors were based on competitive binding between dextran and glucose to concanavalin A and incorporated long-wavelength fluorescence dye pairs. Testing characteristics included spectral response, linearity, sensitivity, limit of detection, kinetic response, reversibility, stability, precision, and accuracy. The biosensor demonstrated a fluorescence change of 45% in the presence of 400 mg/dL glucose, a mean absolute relative difference of less than 11%, a limit of detection of 25 mg/dL, a response time of 15 min, and a decay in fluorescence intensity of 72% over 30 days. The battery of tests presented here for objective, quantitative in vitro evaluation of FRET glucose biosensors performance have the potential to form the basis of future consensus standards. By implementing these test methods for a long-visible-wavelength biosensor, we were able to demonstrate strengths and weaknesses with a new level of thoroughness and rigor.
Fink, Elian; de Rosnay, Marc; Wierda, Marlies; Koot, Hans M; Begeer, Sander
2014-09-01
The empirical literature has presented inconsistent evidence for deficits in the recognition of basic emotion expressions in children with autism spectrum disorders (ASD), which may be due to the focus on research with relatively small sample sizes. Additionally, it is proposed that although children with ASD may correctly identify emotion expression they rely on more deliberate, more time-consuming strategies in order to accurately recognize emotion expressions when compared to typically developing children. In the current study, we examine both emotion recognition accuracy and response time in a large sample of children, and explore the moderating influence of verbal ability on these findings. The sample consisted of 86 children with ASD (M age = 10.65) and 114 typically developing children (M age = 10.32) between 7 and 13 years of age. All children completed a pre-test (emotion word-word matching), and test phase consisting of basic emotion recognition, whereby they were required to match a target emotion expression to the correct emotion word; accuracy and response time were recorded. Verbal IQ was controlled for in the analyses. We found no evidence of a systematic deficit in emotion recognition accuracy or response time for children with ASD, controlling for verbal ability. However, when controlling for children's accuracy in word-word matching, children with ASD had significantly lower emotion recognition accuracy when compared to typically developing children. The findings suggest that the social impairments observed in children with ASD are not the result of marked deficits in basic emotion recognition accuracy or longer response times. However, children with ASD may be relying on other perceptual skills (such as advanced word-word matching) to complete emotion recognition tasks at a similar level as typically developing children.
Neurocognitive Effects of Radiotherapy
2015-10-01
performance of the two groups on the Audiovisual Attentional Shift Test did not differ. These tests have not been used previously within the proton...Timing Functions, Serial Response, and Audiovisual Attentional Shift) Table 2. Organs at Risk. #The percent of patients with radiation doses exceeding the
White, Nicholas A; Danelson, Kerry A; Gayzik, F Scott; Stitzel, Joel D
2014-11-01
A finite element (FE) simulation environment has been developed to investigate aviator head and neck response during a simulated rotary-wing aircraft impact using both an FE anthropomorphic test device (ATD) and an FE human body model. The head and neck response of the ATD simulation was successfully validated against an experimental sled test. The majority of the head and neck transducer time histories received a CORrelation and analysis (CORA) rating of 0.7 or higher, indicating good overall correlation. The human body model simulation produced a more biofidelic head and neck response than the ATD experimental test and simulation, including change in neck curvature. While only the upper and lower neck loading can be measured in the ATD, the shear force, axial force, and bending moment were reported for each level of the cervical spine in the human body model using a novel technique involving cross sections. This loading distribution provides further insight into the biomechanical response of the neck during a rotary-wing aircraft impact.
Matsumoto, N.; Roeloffs, E.A.
2003-01-01
28 coseismic groundwater level decreases have been observed at the Haibara well, Shizuoka prefecture, central Japan, from 1981 to 1997. These groundwater level changes cannot be explained as the poroelastic response to coseismic static strain. We use the atmospheric pressure and tidal responses of the well, rock properties measured on core samples from the same formation and pumping test results to characterize the hydraulic and mechanical properties of the aquifer. The responses of the Haibara well to the M2 Earth tide constituent and to atmospheric pressure have varied over time. In particular, increasing amplitude and decreasing phase lags were observed after the 1993 pumping test, as well as after earthquakes that caused coseismic water level changes. The tidal response, together with the surface load efficiency derived from the atmospheric pressure response, is used to estimate the mechanical properties of the aquifer. The largest amplitude of the M2 constituent, 2.2 mm, is small enough to imply that pore fluid in this system is approximately twice as compressible as water, possibly due to the presence of a small amount of exsolved gas. Diffusion of a coseismic pressure drop near the well could account for the observed time histories of the water level changes. The time histories of the water level drops are well matched by the decay of a coseismic pressure drop at least 80 m away from the well. Removal of a small amount of gas from the formation in that location might in turn explain the coseismic pressure drops.
Yu, Xiao-cui; Liu, Gao-feng; Wang, Xin
2011-02-01
To optimize the preparation technics of wumeitougu oral liquid (WTOL) by response surface methodology. Based on the single-factor tests, the times of WTOL extraction, alcohol precipitation concentration and pH value were selected as three factors for box-behnken central composite design. The response surface methodology was used to optimize the parameters of the preparation. Under the condition of extraction time 1.5 h, extraction times 2.772, the relative density 1.12, alcohol precipitation concentration 68.704%, and pH value 5.0, he theory highest content of Asperosaponin VI was up to 549.908 mg/L. Considering the actual situation, the conditions were amended to three extract times, alcohol precipitation concentration 69%, pH value 5.0, and the content of Dipsacaceae VI saponin examined was 548.63 mg/L which was closed to the theoretical value. The optimized preparation technics of WTOL by response surface methodology is reasonable and feasible.
Response time effects of alerting tone and semantic context for synthesized voice cockpit warnings
NASA Technical Reports Server (NTRS)
Simpson, C. A.; Williams, D. H.
1980-01-01
Some handbooks and human factors design guides have recommended that a voice warning should be preceded by a tone to attract attention to the warning. As far as can be determined from a search of the literature, no experimental evidence supporting this exists. A fixed-base simulator flown by airline pilots was used to test the hypothesis that the total 'system-time' to respond to a synthesized voice cockpit warning would be longer when the message was preceded by a tone because the voice itself was expected to perform both the alerting and the information transfer functions. The simulation included realistic ATC radio voice communications, synthesized engine noise, cockpit conversation, and realistic flight routes. The effect of a tone before a voice warning was to lengthen response time; that is, responses were slower with an alerting tone. Lengthening the voice warning with another work, however, did not increase response time.
Williamson, A M; Feyer, A M; Mattick, R P; Friswell, R; Finlay-Brown, S
2001-05-01
The effects of 28 h of sleep deprivation were compared with varying doses of alcohol up to 0.1% blood alcohol concentration (BAC) in the same subjects. The study was conducted in the laboratory. Twenty long-haul truck drivers and 19 people not employed as professional drivers acted as subjects. Tests were selected that were likely to be affected by fatigue, including simple reaction time, unstable tracking, dual task, Mackworth clock vigilance test, symbol digit coding, visual search, sequential spatial memory and logical reasoning. While performance effects were seen due to alcohol for all tests, sleep deprivation affected performance on most tests, but had no effect on performance on the visual search and logical reasoning tests. Some tests showed evidence of a circadian rhythm effect on performance, in particular, simple reaction time, dual task, Mackworth clock vigilance, and symbol digit coding, but only for response speed and not response accuracy. Drivers were slower but more accurate than controls on the symbol digit test, suggesting that they took a more conservative approach to performance of this test. This study demonstrated which tests are most sensitive to sleep deprivation and fatigue. The study therefore has established a set of tests that can be used in evaluations of fatigue and fatigue countermeasures.
NASA Technical Reports Server (NTRS)
Nicholson, Lee M.; Whitley, Karen S.; Gates, Thomas S.
2000-01-01
The effect of molecular weight on the viscoelastic performance of an advanced polymer (LaRC-SI) was investigated through the use of creep compliance tests. Testing consisted of short-term isothermal creep and recovery with the creep segments performed under constant load. The tests were conducted at three temperatures below the glass transition temperature of five materials of different molecular weight. Through the use of time-aging-time superposition procedures, the material constants, material master curves and aging-related parameters were evaluated at each temperature for a given molecular weight. The time-temperature superposition technique helped to describe the effect of temperature on the timescale of the viscoelastic response of each molecular weight. It was shown that the low molecular weight materials have higher creep compliance and creep rate, and are more sensitive to temperature than the high molecular weight materials. Furthermore, a critical molecular weight transition was observed to occur at a weight-average molecular weight of M (bar) (sub w) 25000 g/mol below which, the temperature sensitivity of the time-temperature superposition shift factor increases rapidly. The short-term creep compliance data were used in association with Struik's effective time theory to predict the long-term creep compliance behavior for the different molecular weights. At long timescales, physical aging serves to significantly decrease the creep compliance and creep rate of all the materials tested.
Real-time simulation of the nonlinear visco-elastic deformations of soft tissues.
Basafa, Ehsan; Farahmand, Farzam
2011-05-01
Mass-spring-damper (MSD) models are often used for real-time surgery simulation due to their fast response and fairly realistic deformation replication. An improved real time simulation model of soft tissue deformation due to a laparoscopic surgical indenter was developed and tested. The mechanical realization of conventional MSD models was improved using nonlinear springs and nodal dampers, while their high computational efficiency was maintained using an adapted implicit integration algorithm. New practical algorithms for model parameter tuning, collision detection, and simulation were incorporated. The model was able to replicate complex biological soft tissue mechanical properties under large deformations, i.e., the nonlinear and viscoelastic behaviors. The simulated response of the model after tuning of its parameters to the experimental data of a deer liver sample, closely tracked the reference data with high correlation and maximum relative differences of less than 5 and 10%, for the tuning and testing data sets respectively. Finally, implementation of the proposed model and algorithms in a graphical environment resulted in a real-time simulation with update rates of 150 Hz for interactive deformation and haptic manipulation, and 30 Hz for visual rendering. The proposed real time simulation model of soft tissue deformation due to a laparoscopic surgical indenter was efficient, realistic, and accurate in ex vivo testing. This model is a suitable candidate for testing in vivo during laparoscopic surgery.
Nolte, S; Mierke, A; Fischer, H F; Rose, M
2016-06-01
Significant life events such as severe health status changes or intensive medical treatment often trigger response shifts in individuals that may hamper the comparison of measurements over time. Drawing from the Oort model, this study aims at detecting response shift at the item level in psychosomatic inpatients and evaluating its impact on the validity of comparing repeated measurements. Complete pretest and posttest data were available from 1188 patients who had filled out the ICD-10 Symptom Rating (ISR) scale at admission and discharge, on average 24 days after intake. Reconceptualization, reprioritization, and recalibration response shifts were explored applying tests of measurement invariance. In the item-level approach, all model parameters were constrained to be equal between pretest and posttest. If non-invariance was detected, these were linked to the different types of response shift. When constraining across-occasion model parameters, model fit worsened as indicated by a significant Satorra-Bentler Chi-square difference test suggesting potential presence of response shifts. A close examination revealed presence of two types of response shift, i.e., (non)uniform recalibration and both higher- and lower-level reconceptualization response shifts leading to four model adjustments. Our analyses suggest that psychosomatic inpatients experienced some response shifts during their hospital stay. According to the hierarchy of measurement invariance, however, only one of the detected non-invariances is critical for unbiased mean comparisons over time, which did not have a substantial impact on estimating change. Hence, the use of the ISR can be recommended for outcomes assessment in clinical routine, as change score estimates do not seem hampered by response shift effects.
Chan, Andy C M; Ouyang, Xi H; Jehu, Deborah A M; Chung, Raymond C K; Pang, Marco Y C
2018-01-01
Balance deficits are common after total knee arthroplasty (TKA); however the responsiveness of commonly used balance measurement tools has not been well defined. The objective of this prospective study was to compare the internal and external responsiveness of four measurement tools in assessing recovery of balance function following TKA. A total of 134 individuals with TKA (95 women; age: 66.3±6.6years) completed the Balance Evaluation Systems Test (BESTest), Mini-BESTest, Brief-BESTest, and Berg Balance Scale (BBS) at 2, 4, 8, 12, and 24 weeks post-TKA. The Functional Gait Assessment (FGA) served as the anchor measure, and was also measured across these time points. Internal responsiveness was indicated by the standardized response mean (SRM), while external responsiveness was reflected by the degree of association of the changes of balance scores with those of FGA. The SRM ranged from 0.60-1.14 for the BESTest, 0.40-0.94 for the Mini-BESTest, 0.27-0.91 for the Brief-BESTest, and 0.19-0.70 for the BBS, over time. The change in BESTest and Mini-BESTest scores predicted the change in the FGA scores across all time periods, except for the Mini-BESTest between weeks 12-24, accounting for 13-27%, and 12-24% of the variance, respectively. The Brief-BESTest scores only predicted FGA scores between the weeks 2-4 (R 2 =20%). The changes in BBS scores were not associated with the FGA. The BESTest is the most responsive in measuring recovery of balance among individuals with TKA. The Mini-BESTest is a reasonable option during time constraints. Copyright © 2017. Published by Elsevier B.V.
Distinguishing Fast and Slow Processes in Accuracy - Response Time Data
Coomans, Frederik; Hofman, Abe; Brinkhuis, Matthieu; van der Maas, Han L. J.; Maris, Gunter
2016-01-01
We investigate the relation between speed and accuracy within problem solving in its simplest non-trivial form. We consider tests with only two items and code the item responses in two binary variables: one indicating the response accuracy, and one indicating the response speed. Despite being a very basic setup, it enables us to study item pairs stemming from a broad range of domains such as basic arithmetic, first language learning, intelligence-related problems, and chess, with large numbers of observations for every pair of problems under consideration. We carry out a survey over a large number of such item pairs and compare three types of psychometric accuracy-response time models present in the literature: two ‘one-process’ models, the first of which models accuracy and response time as conditionally independent and the second of which models accuracy and response time as conditionally dependent, and a ‘two-process’ model which models accuracy contingent on response time. We find that the data clearly violates the restrictions imposed by both one-process models and requires additional complexity which is parsimoniously provided by the two-process model. We supplement our survey with an analysis of the erroneous responses for an example item pair and demonstrate that there are very significant differences between the types of errors in fast and slow responses. PMID:27167518
NASA Technical Reports Server (NTRS)
Silva, Walter A.; Vartio, Eric; Shimko, Anthony; Kvaternik, Raymond G.; Eure, Kenneth W.; Scott,Robert C.
2007-01-01
Aeroservoelastic (ASE) analytical models of a SensorCraft wind-tunnel model are generated using measured data. The data was acquired during the ASE wind-tunnel test of the HiLDA (High Lift-to-Drag Active) Wing model, tested in the NASA Langley Transonic Dynamics Tunnel (TDT) in late 2004. Two time-domain system identification techniques are applied to the development of the ASE analytical models: impulse response (IR) method and the Generalized Predictive Control (GPC) method. Using measured control surface inputs (frequency sweeps) and associated sensor responses, the IR method is used to extract corresponding input/output impulse response pairs. These impulse responses are then transformed into state-space models for use in ASE analyses. Similarly, the GPC method transforms measured random control surface inputs and associated sensor responses into an AutoRegressive with eXogenous input (ARX) model. The ARX model is then used to develop the gust load alleviation (GLA) control law. For the IR method, comparison of measured with simulated responses are presented to investigate the accuracy of the ASE analytical models developed. For the GPC method, comparison of simulated open-loop and closed-loop (GLA) time histories are presented.
NASA Technical Reports Server (NTRS)
Silva, Walter A.; Shimko, Anthony; Kvaternik, Raymond G.; Eure, Kenneth W.; Scott, Robert C.
2006-01-01
Aeroservoelastic (ASE) analytical models of a SensorCraft wind-tunnel model are generated using measured data. The data was acquired during the ASE wind-tunnel test of the HiLDA (High Lift-to-Drag Active) Wing model, tested in the NASA Langley Transonic Dynamics Tunnel (TDT) in late 2004. Two time-domain system identification techniques are applied to the development of the ASE analytical models: impulse response (IR) method and the Generalized Predictive Control (GPC) method. Using measured control surface inputs (frequency sweeps) and associated sensor responses, the IR method is used to extract corresponding input/output impulse response pairs. These impulse responses are then transformed into state-space models for use in ASE analyses. Similarly, the GPC method transforms measured random control surface inputs and associated sensor responses into an AutoRegressive with eXogenous input (ARX) model. The ARX model is then used to develop the gust load alleviation (GLA) control law. For the IR method, comparison of measured with simulated responses are presented to investigate the accuracy of the ASE analytical models developed. For the GPC method, comparison of simulated open-loop and closed-loop (GLA) time histories are presented.
Impaired Enterohormone Response Following a Liquid Test Meal in Gastrectomized Patients.
Santarpia, Lidia; Pagano, Maria Carmen; Cioffi, Iolanda; Alfonsi, Lucia; Cuomo, Rosario; Labruna, Giuseppe; Sacchetti, Lucia; Contaldo, Franco; Pasanisi, Fabrizio
2017-01-01
Total gastrectomy (TG) is responsible for symptoms or disturbance of alimentary status (changes in body weight, food intake per meal and frequency of meal per day) which, in turn are responsible for weight loss and malnutrition. The study evaluates the gut hormone responses in totally gastrectomized (TG) patients after a liquid meal test. Twenty total gastrectomized cancer-free patients (12 M, 8 F, 56.4 ± 10.2 years, BMI 21.4 ± 2.2 kg/m2) and 10 healthy volunteers (4 M, 6 F, 48.0 ± 12.7 years, BMI 26.7 ± 3.0 kg/m2 ) drank a liquid meal (1.25 kcal/mL) at the rate of 50 mL/5' min for a maximum of 30 min. Satiety score was assessed and blood sample was taken at different time points. The time response course, particularly for insulin, glucose-like pepetide-1, and cholecystokinin, significantly differed between TG patients and controls. Our results may help to better understand hormone responses triggered by the faster arrival of nutrients in the small bowel and to explain some post-TG symptoms. © 2017 S. Karger AG, Basel.
Prediction of Flutter Boundary Using Flutter Margin for The Discrete-Time System
NASA Astrophysics Data System (ADS)
Dwi Saputra, Angga; Wibawa Purabaya, R.
2018-04-01
Flutter testing in a wind tunnel is generally conducted at subcritical speeds to avoid damages. Hence, The flutter speed has to be predicted from the behavior some of its stability criteria estimated against the dynamic pressure or flight speed. Therefore, it is quite important for a reliable flutter prediction method to estimates flutter boundary. This paper summarizes the flutter testing of a wing cantilever model in a wind tunnel. The model has two degree of freedom; they are bending and torsion modes. The flutter test was conducted in a subsonic wind tunnel. The dynamic data responses was measured by two accelerometers that were mounted on leading edge and center of wing tip. The measurement was repeated while the wind speed increased. The dynamic responses were used to determine the parameter flutter margin for the discrete-time system. The flutter boundary of the model was estimated using extrapolation of the parameter flutter margin against the dynamic pressure. The parameter flutter margin for the discrete-time system has a better performance for flutter prediction than the modal parameters. A model with two degree freedom and experiencing classical flutter, the parameter flutter margin for the discrete-time system gives a satisfying result in prediction of flutter boundary on subsonic wind tunnel test.
Al-Sabah, Suleiman; Alasfar, Fahad; Al-Khaledi, Ghanim; Dinesh, Reshma; Al-Saleh, Mervat; Abul, Habib
2014-01-01
Currently, the most effective treatment for obesity is bariatric surgery. Gastroduodenal bypass surgery produces sustained weight loss and improves glycemic control and insulin sensitivity. Previous studies have shown that sleeve gastrectomy (SG) produces similar results and implicate changes in incretin hormone release in these effects. Male Sprague-Dawley rats were divided into four groups; lean control (lean), diet-induced obesity (DIO), DIO animals that had undergone SG (SG), and DIO animals that had undergone a sham operation (sham). After a 2-week recovery period, the incretin response to a standard test meal was measured. Blood sampling was performed in free-moving rats at various time points using chronic vascular access to the right jugular vein. There was a significant increase in the bodyweight of DIO animals fed a high-fat/high-sugar diet compared with the lean animals, which was reversed by SG. DIO caused an impairment of the GLP-1 response to a standard test meal, but not the GIP response. SG resulted in a dramatic increase in the GLP-1 response to a standard test meal but had no effect on the GIP response. A rapid rise in blood sugar was observed in the SG group following a standard test meal that was followed by reactive hypoglycemia. SG dramatically increases the GLP-1 response to a standard test meal but has no effect on GIP in a rat model of DIO.
On use of the multistage dose-response model for assessing laboratory animal carcinogenicity
Nitcheva, Daniella; Piegorsch, Walter W.; West, R. Webster
2007-01-01
We explore how well a statistical multistage model describes dose-response patterns in laboratory animal carcinogenicity experiments from a large database of quantal response data. The data are collected from the U.S. EPA’s publicly available IRIS data warehouse and examined statistically to determine how often higher-order values in the multistage predictor yield significant improvements in explanatory power over lower-order values. Our results suggest that the addition of a second-order parameter to the model only improves the fit about 20% of the time, while adding even higher-order terms apparently does not contribute to the fit at all, at least with the study designs we captured in the IRIS database. Also included is an examination of statistical tests for assessing significance of higher-order terms in a multistage dose-response model. It is noted that bootstrap testing methodology appears to offer greater stability for performing the hypothesis tests than a more-common, but possibly unstable, “Wald” test. PMID:17490794
Investigations in site response from ground motion observations in vertical arrays
NASA Astrophysics Data System (ADS)
Baise, Laurie Gaskins
The aim of the research is to improve the understanding of earthquake site response and to improve the techniques available to investigate issues in this field. Vertical array ground motion data paired with the empirical transfer function (ETF) methodology is shown to accurately characterize site response. This manuscript draws on methods developed in the field of signal processing and statistical time series analysis to parameterize the ETF as an autoregressive moving-average (ARMA) system which is justified theoretically, historically, and by example. Site response is evaluated at six sites in California, Japan, and Taiwan using ETF estimates, correlation analysis, and full waveform modeling. Correlation analysis is proposed as a required data quality evaluation imperative to any subsequent site response analysis. ETF estimates and waveform modeling are used to decipher the site response at sites with simple and complex geologic structure, which provide simple time-invariant and time-variant methods for evaluating both linear site transfer functions and nonlinear site response for sites experiencing liquefaction of the soils. The Treasure and Yerba Buena Island sites, however, require 2-D waveform modeling to accurately evaluate the effects of the shallow sedimentary basin. ETFs are used to characterize the Port Island site and corresponding shake table tests before, during, and after liquefaction. ETFs derived from the shake table tests were demonstrated to consistently predict the linear field ground response below 16 m depth and the liquefied behavior above 15 m depth. The liquefied interval response was demonstrated to gradually return to pre-liquefied conditions within several weeks of the 1995 Hyogo-ken Nanbu earthquake. Both the site's and the shake table test's response were shown to be effectively linear up to 0.5 g in the native materials below 16 m depth. The effective linearity of the site response at GVDA, Chiba, and Lotting up to 0.1 g, 0.33 g, and 0.49 g, respectively, further confirms that site response in the field may be more linear than expected from laboratory tests. Strong motions were predicted at these sites with normalized mean square error less than 0.10 using ETFs generated from weak motions. The Treasure Island site response was shown to be dominated by surface waves propagating in the shallow sediments of the San Francisco Bay. Low correlation of the ground motions recorded on rock at Yerba Buena Island and in rock beneath the Treasure Island site intimates that the Yerba Buena site is an inappropriate reference site for Treasure Island site response studies. Accurate simulation of the Treasure Island site response was achieved using a 2-D velocity structure comprised of a 100 m uniform soil basin (Vs = 400 m/s) over a weathered rock veneer (Vs = 1.5 km/s) to 200 m depth.
Binocular summation and peripheral visual response time
NASA Technical Reports Server (NTRS)
Gilliland, K.; Haines, R. F.
1975-01-01
Six males were administered a peripheral visual response time test to the onset of brief small stimuli imaged in 10-deg arc separation intervals across the dark adapted horizontal retinal meridian under both binocular and monocular viewing conditions. This was done in an attempt to verify the existence of peripheral binocular summation using a response time measure. The results indicated that from 50-deg arc right to 50-deg arc left of the line of sight binocular summation is a reasonable explanation for the significantly faster binocular data. The stimulus position by viewing eye interaction was also significant. A discussion of these and other analyses is presented along with a review of related literature.
Efficient and optimized identification of generalized Maxwell viscoelastic relaxation spectra
Babaei, Behzad; Davarian, Ali; Pryse, Kenneth M.; Elson, Elliot L.; Genin, Guy M.
2017-01-01
Viscoelastic relaxation spectra are essential for predicting and interpreting the mechanical responses of materials and structures. For biological tissues, these spectra must usually be estimated from viscoelastic relaxation tests. Interpreting viscoelastic relaxation tests is challenging because the inverse problem is expensive computationally. We present here an efficient algorithm that enables rapid identification of viscoelastic relaxation spectra. The algorithm was tested against trial data to characterize its robustness and identify its limitations and strengths. The algorithm was then applied to identify the viscoelastic response of reconstituted collagen, revealing an extensive distribution of viscoelastic time constants. PMID:26523785
Wavelet Applications for Flight Flutter Testing
NASA Technical Reports Server (NTRS)
Lind, Rick; Brenner, Marty; Freudinger, Lawrence C.
1999-01-01
Wavelets present a method for signal processing that may be useful for analyzing responses of dynamical systems. This paper describes several wavelet-based tools that have been developed to improve the efficiency of flight flutter testing. One of the tools uses correlation filtering to identify properties of several modes throughout a flight test for envelope expansion. Another tool uses features in time-frequency representations of responses to characterize nonlinearities in the system dynamics. A third tool uses modulus and phase information from a wavelet transform to estimate modal parameters that can be used to update a linear model and reduce conservatism in robust stability margins.
Rossion, Bruno; Michel, Caroline
2018-03-16
We report normative data from a large (N = 307) sample of young adult participants tested with a computerized version of the long form of the classical Benton Facial Recognition Test (BFRT; Benton & Van Allen, 1968). The BFRT-c requires participants to match a target face photograph to either one or three of six face photographs presented simultaneously. We found that the percent accuracy on the BFRT-c (81%-83%) was below ceiling yet well above chance level, with little interindividual variance in this typical population sample, two important aspects of a sensitive clinical test. Although the split-half reliability on response accuracy was relatively low, due to the large variability in difficulty across items, the correct response times measured in this version-completed in 3 min, on average-provide a reliable and critical complementary measure of performance at individual unfamiliar-face matching. In line with previous observations from other measures, females outperformed male participants at the BFRT-c, especially for female faces. In general, performance was also lower following lighting changes than following head rotations, in line with previous studies that have emphasized participants' limited ability to match pictures of unfamiliar faces with important variations in illumination. Overall, this normative data set supports the validity of the BFRT-c as a key component of a battery of tests to identify clinical impairments in individual face recognition, such as observed in acquired prosopagnosia. However, this analysis strongly recommends that researchers consider the full test results: Beyond global indexes of performance based on accuracy rates only, they should consider the time taken to match individual faces as well as the variability in performance across items.
75 FR 67227 - Relocation Cost Sharing in the Broadcast Auxiliary Service
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-02
... relocating parties. In the process, the Commission balances the responsibilities for and benefits of... well as to balance the responsibilities for and benefits of relocating incumbent BAS operations among... adhere closely to these time-tested principles to balance the interest of incumbent licensees, new...
Yung, Marcus; Wells, Richard P
2017-07-01
Fatigue has been linked to deficits in production quality and productivity and, if of long duration, work-related musculoskeletal disorders. It may thus be a useful risk indicator and design and evaluation tool. However, there is limited information on the test-retest reliability, the sensitivity and the effects of diurnal fluctuation on field usable fatigue measures. This study reports on an evaluation of 11 measurement tools and their 14 parameters. Eight measures were found to have test-retest ICC values greater than 0.8. Four measures were particularly responsive during an intermittent fatiguing condition. However, two responsive measures demonstrated rhythmic behaviour, with significant time effects from 08:00 to mid-afternoon and early evening. Action tremor, muscle mechanomyography and perceived fatigue were found to be most reliable and most responsive; but additional analytical considerations might be required when interpreting daylong responses of MMG and action tremor. Practitioner Summary: This paper presents findings from test-retest and daylong reliability and responsiveness evaluations of 11 fatigue measures. This paper suggests that action tremor, muscle mechanomyography and perceived fatigue were most reliable and most responsive. However, mechanomyography and action tremor may be susceptible to diurnal changes.
Norepinephrine and impulsivity: Effects of acute yohimbine
Swann, Alan C.; Lijffijt, Marijn; Lane, Scott D.; Cox, Blake; Steinberg, Joel L.; Moeller, F. Gerard
2013-01-01
Rationale Rapid-response impulsivity, characterized by inability to withhold response to a stimulus until it is adequately appraised, is associated with risky behavior and may be increased in a state-dependent manner by norepinephrine. Objective We assessed effects of yohimbine, which increases norepinephrine release by blocking alpha-2 noradrenergic receptors, on plasma catecholamine metabolites, blood pressure, subjective symptoms, and laboratory-measured rapid-response impulsivity. Methods Subjects were twenty-three healthy controls recruited from the community, with normal physical examination and ECG, and negative history for hypertension, cardiovascular illness, and Axis I or II disorder. Blood pressure, pulse, and behavioral measures were obtained before and periodically after 0.4 mg/kg oral yohimbine or placebo in a randomized, counterbalanced design. Metabolites of norepinephrine (3-methoxy-4-hydroxyphenylglycol, MHPG; vanillylmandelic acid, VMA) and dopamine (homovanillic acid, HVA) were measured by high pressure liquid chromatography with electrochemical detection. Rapid-response impulsivity was measured by commission errors and reaction times on the Immediate Memory Task (IMT), a continuous performance test designed to measure impulsivity and attention. Results Yohimbine increased plasma MHPG and VMA but not HVA. Yohimbine increased systolic and diastolic blood pressure and pulse rate. On the IMT, yohimbine increased impulsive errors and impulsive response bias and accelerated reaction times. Yohimbine-associated increase in plasma MHPG correlated with increased impulsive response rates. Time courses varied; effects on blood pressure generally preceded those on metabolites and test performance. Conclusions These effects are consistent with increased rapid-response impulsivity after pharmacological noradrenergic stimulation in healthy controls. Labile noradrenergic responses, or increased sensitivity to norepinephrine, may increase risk for impulsive behavior. PMID:23559222
The impact of anxiety and catastrophizing on interleukin-6 responses to acute painful stress
Lazaridou, Asimina; Martel, Marc O; Cahalan, Christine M; Cornelius, Marise C; Franceschelli, Olivia; Campbell, Claudia M; Haythornthwaite, Jennifer A; Smith, Michael; Riley, Joseph; Edwards, Robert R
2018-01-01
Objective To examine the influence of anxiety and pain-related catastrophizing on the time course of acute interleukin-6 (IL-6) responses to standardized noxious stimulation among patients with chronic pain. Methods Data were collected from 48 participants in the following demographically matched groups: patients with chronic pain (n=36) and healthy controls (n=12). Participants underwent a series of Quantitative Sensory Testing (QST) procedures assessing responses to mechanical and thermal stimuli during two separate visits, in a randomized order. One visit consisted of standard, moderately painful QST procedures, while the other visit involved nonpainful analogs to these testing procedures. Blood samples were taken at baseline, and then for up to 2 hours after QST in order to study the time course of IL-6 responses. Results Results of multilevel analyses revealed that IL-6 responses increased across assessment time points in both visits (p<0.001). While patients with chronic pain and healthy controls did not differ in the magnitude of IL-6 responses, psychological factors influenced IL-6 trajectories only in the chronic pain group. Among patients, increases in catastrophizing over the course of the QST session were associated with elevated IL-6 responses only during the painful QST session (p<0.05). When controlling for anxiety, results indicated that the main multilevel model among patients remained significant (p<0.05). Conclusion Under specific conditions (eg, application of a painful stressor), catastrophizing may be associated with amplified proinflammatory responses in patients with persistent pain. These findings suggest that psychosocial interventions that reduce negative pain-related cognitions may benefit patients’ inflammatory profiles. PMID:29636630
Viscoplastic Characterization of Ti-6-4: Experiments
NASA Technical Reports Server (NTRS)
Lerch, Bradley A.; Arnold, Steven M.
2016-01-01
As part of a continued effort to improve the understanding of material time-dependent response, a series of mechanical tests have been conducted on the titanium alloy, Ti-6Al-4V. Tensile, creep, and stress relaxation tests were performed over a wide range of temperatures and strain rates to engage various amounts of time-dependent behavior. Additional tests were conducted that involved loading steps, overloads, dwell periods, and block loading segments to characterize the interaction between plasticity and time-dependent behavior. These data will be used to characterize a recently developed, viscoelastoplastic constitutive model with a goal toward better estimates of aerospace component behavior, resulting in improved safety.
Stansfield, Kirstie H; Kirstein, Cheryl L
2007-04-01
Adolescence is a time of high-risk behavior and increased exploration. This developmental period is marked by a greater probability to initiate drug use and is associated with an increased risk to develop addiction and adulthood dependency and drug use at this time is associated with an increased risk. Human adolescents are predisposed toward an increased likelihood of risk-taking behaviors [Zuckerman M. Sensation seeking and the endogenous deficit theory of drug abuse. NIDA Res Monogr 1986;74:59-70.], including drug use or initiation. In the present study, adolescent animals were exposed to twenty days of either saline (0.9% sodium chloride), cocaine (20 mg/kg) or ethanol (1 g/kg) i.p. followed by a fifteen-day washout period. All animals were tested as adults on several behavioral measures including locomotor activity induced by a novel environment, time spent in the center of an open field, novelty preference and novel object exploration. Animals exposed to cocaine during adolescence and tested as adults exhibited a greater locomotor response in a novel environment, spent less time in the center of the novel open field and spent less time with a novel object, results that are indicative of a stress or anxiogenic response to novelty or a novel situation. Adolescent animals chronically administered ethanol and tested as adults, unlike cocaine-exposed were not different from controls in a novel environment, indicated by locomotor activity or time spent with a novel object. However, ethanol-exposed animals approached the novel object more, suggesting that exposure to ethanol during development may result in less-inhibited behaviors during adulthood. The differences in adult behavioral responses after drug exposure during adolescence are likely due to differences in the mechanisms of action of the drugs and subsequent reward and/or stress responsivity. Future studies are needed to determine the neural substrates of these long lasting drug-induced changes.
Emergency medical services and congestion : urban sprawl and pre-hospital emergency care time.
DOT National Transportation Integrated Search
2009-01-01
This research measured the association between urban sprawl and emergency medical service (EMS) response time. The purpose was to test the hypothesis that features of the built environment increase the probability of delayed ambulance arrival. Using ...
Cooper, Simon B; Dring, Karah J; Morris, John G; Sunderland, Caroline; Bandelow, Stephan; Nevill, Mary E
2018-05-08
An acute bout of exercise elicits a beneficial effect on subsequent cognitive function in adolescents. The effect of games-based activity, an ecologically valid and attractive exercise model for young people, remains unknown; as does the moderating effect of fitness on the acute exercise-cognition relationship. Therefore, the aim of the present study was to examine the effect of games-based activity on subsequent cognition in adolescents, and the moderating effect of fitness on this relationship. Following ethical approval, 39 adolescents (12.3 ± 0.7 year) completed an exercise and resting trial in a counterbalanced, randomised crossover design. During familiarisation, participants completed a multi-stage fitness test to predict VO 2 peak. The exercise trial consisted of 60-min games-based activity (basketball), during which heart rate was 158 ± 11 beats∙min - 1 . A battery of cognitive function tests (Stroop test, Sternberg paradigm, trail making and d2 tests) were completed 30-min before, immediately following and 45-min following the basketball. Response times on the complex level of the Stroop test were enhanced both immediately (p = 0.021) and 45-min (p = 0.035) post-exercise, and response times on the five item level of the Sternberg paradigm were enhanced immediately post-exercise (p = 0.023). There were no effects on the time taken to complete the trail making test or any outcome of the d2 test. In particular, response times were enhanced in the fitter adolescents 45-min post-exercise on both levels of the Stroop test (simple, p = 0.005; complex, p = 0.040) and on the three item level of the Sternberg paradigm immediately (p = 0.017) and 45-min (p = 0.008) post-exercise. Games-based activity enhanced executive function and working memory scanning speed in adolescents, an effect particularly evident in fitter adolescents, whilst the high intensity intermittent nature of games-based activity may be too demanding for less fit children.
Kim, Nancy; Boone, Kyle B; Victor, Tara; Lu, Po; Keatinge, Carolyn; Mitchell, Cary
2010-08-01
Recently published practice standards recommend that multiple effort indicators be interspersed throughout neuropsychological evaluations to assess for response bias, which is most efficiently accomplished through use of effort indicators from standard cognitive tests already included in test batteries. The present study examined the utility of a timed recognition trial added to standard administration of the WAIS-III Digit Symbol subtest in a large sample of "real world" noncredible patients (n=82) as compared with credible neuropsychology clinic patients (n=89). Scores from the recognition trial were more sensitive in identifying poor effort than were standard Digit Symbol scores, and use of an equation incorporating Digit Symbol Age-Corrected Scaled Scores plus accuracy and time scores from the recognition trial was associated with nearly 80% sensitivity at 88.7% specificity. Thus, inclusion of a brief recognition trial to Digit Symbol administration has the potential to provide accurate assessment of response bias.
Blyth, T; Hunter, J A; Stirling, A
1994-05-01
Since the introduction of intra-articular steroid therapy 40 yr ago there have been many changes in the treatment of rheumatoid patients. Previous studies suggest differing times of response for the same agents. This study reports the response, measured by a five-point pain chart, of 300 patients with painful rheumatoid knees. Sixty received hydrocortisone succinate (HC), 150 received triamcinolone acetonide (TA), and 120 triamcinolone hexacetonide (TH). Results demonstrated little effect with HC, but good responses with TA and TH. More patients were rendered painfree for a longer time with TH; 18% at 12 weeks, as against 9% with TA (chi 2 test P < 0.005). At 12 weeks 59% showed continued improvement with TH as against 44% with TA (chi 2 test P < 0.05). TH is the preferred preparation for injection of the rheumatoid knee.
The efficacy of the new SCD response compression system in the prevention of venous stasis.
Kakkos, S K; Szendro, G; Griffin, M; Daskalopoulou, S S; Nicolaides, A N
2000-11-01
The current commercially available sequential intermittent pneumatic compression device used for the prevention of deep venous thrombosis has a constant cycle of 11 seconds' compression and 60 seconds' deflation. This deflation period ensures that the veins are filled before the subsequent cycle begins. It has been suggested that in some positions (eg, semirecumbent or sitting) and with different patients (eg, those with venous reflux), refilling of the veins may occur much earlier than 60 seconds, and thus a more frequent cycle may be more effective in expelling blood proximally. The aim of the study was to test the effectiveness of a new sequential compression system (the SCD Response Compression System), which has the ability to detect the change in the venous volume and to respond by initiating the subsequent cycle when the veins are substantially full. In an open controlled trial at an academic vascular laboratory, the SCD Response Compression System was tested against the existing SCD Sequel Compression System in 12 healthy volunteers who were in supine, semirecumbent, and sitting positions. The refilling time sensed by the device was compared with that determined from recordings of femoral vein flow velocity by the use of duplex ultrasound scan. The total volume of blood expelled per hour during compression was compared with that produced by the existing SCD system in the same volunteers and positions. The refilling time determined automatically by the SCD Response Compression System varied from 24 to 60 seconds in the subjects tested, demonstrating individual patient variation. The refilling time (mean +/- SD) in the sitting position was 40.6 +/- 10. 0 seconds, which was significantly longer (P <.001) than that measured in the supine and semirecumbent positions, 33.8 +/- 4.1 and 35.6 +/- 4.9 seconds, respectively. There was a linear relationship between the duplex scan-derived refill time (mean of 6 readings per leg) and the SCD Response device-derived refill time (r = 0.85, P <. 001). The total volume of blood (mean +/- SD) expelled per hour by the existing SCD Sequel device in the supine, semirecumbent, and sitting positions was 2.23 +/- 0.90 L/h, 2.47 +/- 0.86 L/h, and 3.28 +/- 1.24 L/h, respectively. The SCD Response device increased the volume expelled to 3.92 +/- 1.60 L/h or a 76% increase (P =.001) in the supine position, to 3.93 +/- 1.55 L/h or a 59% increase (P =. 001) in the semirecumbent position, and to 3.97 +/- 1.42 L/h or a 21% increase (P =.026) in the sitting position. By achieving more appropriately timed compression cycles over time, the new SCD Response System is effective in preventing venous stasis by means of a new method that improves on the clinically documented effectiveness of the existing SCD system. Further studies testing its potential for improved efficacy in preventing deep venous thrombosis are justified.
Extending surgeon response times in tier 2 traumas does not adversely affect patient outcomes.
Zimmerman, Steven Anthony; Reed, Christopher S; Reed, Alexander N; Jones, Ronald J; Chard, Annette; Reed, Donald N
2018-06-01
The presence of a trauma surgeon during patient resuscitations is required at most American College of Surgeons-verified trauma centers despite little evidence showing improved patient outcomes in the less-than-critically injured (Tier 2) trauma patients. This study was designed to identify the impact of extending required surgeon response times on outcomes in tier 2 trauma patients. An American College of Surgeons-verified level 2 trauma center extended the maximum allowed surgeon response time for tier 2 activations from 60 min to 120 min on November 1, 2011. Surgeon response time and patient outcomes of the retrospective control group (January 1, 2008-October 31, 2011) were then compared with the prospective test group (November 1, 2011-December 31, 2014). Primary outcomes included mortality and hospital length of stay (HLOS). Secondary outcomes were emergency department length of stay, and time from ED arrival to CT scan. A subset analysis of all patients evaluated by a surgeon within 60 min of arrival versus those evaluated by a surgeon after 60 min was also performed. The control and test groups were composed of 757 and 792 patients, and their mean injury severity score was 9.0 and 6.0, respectively. Emergency department length of stay showed a statistically significant increase of 12 min, whereas HLOS was unchanged throughout the study. Mortality was not significantly different between the groups. Subset analysis revealed a median surgeon arrival time of 15 min in the <60-min group and 85 min in the >60-min group, whereas the injury severity score, HLOS, and mortality were not significantly different between these subsets. No correlation existed between these outcomes and surgeon arrival time. Doubling required surgeon response time in tier 2 trauma patients does not produce negative outcomes in this patient group. Mandatory surgeon response times in similar patient groups can be re-evaluated to allow for greater flexibility of a limited surgeon workforce while still providing safe care. Copyright © 2018 Elsevier Inc. All rights reserved.
Spiliopoulos, Leonidas
2018-03-01
The investigation of response time and behavior has a long tradition in cognitive psychology, particularly for non-strategic decision-making. Recently, experimental economists have also studied response time in strategic interactions, but with an emphasis on either one-shot games or repeated social-dilemmas. I investigate the determinants of response time in a repeated (pure-conflict) game, admitting a unique mixed strategy Nash equilibrium, with fixed partner matching. Response times depend upon the interaction of two decision models embedded in a dual-process framework (Achtziger and Alós-Ferrer, 2014; Alós-Ferrer, 2016). The first decision model is the commonly used win-stay/lose-shift heuristic and the second the pattern-detecting reinforcement learning model in Spiliopoulos (2013b). The former is less complex and can be executed more quickly than the latter. As predicted, conflict between these two models (i.e., each one recommending a different course of action) led to longer response times than cases without conflict. The dual-process framework makes other qualitative response time predictions arising from the interaction between the existence (or not) of conflict and which one of the two decision models the chosen action is consistent with-these were broadly verified by the data. Other determinants of RT were hypothesized on the basis of existing theory and tested empirically. Response times were strongly dependent on the actions chosen by both players in the previous rounds and the resulting outcomes. Specifically, response time was shortest after a win in the previous round where the maximum possible payoff was obtained; response time after losses was significantly longer. Strongly auto-correlated behavior (regardless of its sign) was also associated with longer response times. I conclude that, similar to other tasks, there is a strong coupling in repeated games between behavior and RT, which can be exploited to further our understanding of decision making. Copyright © 2017 Elsevier B.V. All rights reserved.
An Examination of the Flynn Effect in the National Intelligence Test in Estonia
ERIC Educational Resources Information Center
Shiu, William
2012-01-01
This study examined the Flynn Effect (FE; i.e., the rise in IQ scores over time) in Estonia from Scale B of the National Intelligence Test using both classical test theory (CTT) and item response theory (IRT) methods. Secondary data from two cohorts (1934, n = 890 and 2006, n = 913) of students were analyzed, using both classical test theory (CTT)…
ERIC Educational Resources Information Center
Paek, Insu; Park, Hyun-Jeong; Cai, Li; Chi, Eunlim
2014-01-01
Typically a longitudinal growth modeling based on item response theory (IRT) requires repeated measures data from a single group with the same test design. If operational or item exposure problems are present, the same test may not be employed to collect data for longitudinal analyses and tests at multiple time points are constructed with unique…
Response Characteristics of a Stable Mixed Potential Ammonia Sensor in Simulated Diesel Exhaust
Ramaiyan, Kannan P.; Pihl, Josh A.; Kreller, Cortney R.; ...
2017-07-15
A mixed potential sensor using Au and Pt dense wire electrodes embedded between tape-casted layers of 8 mol% yttria stabilized zirconia (YSZ) was tested for application toward NH 3, NO, NO 2, C 3H 6 and C 3H 8. In single-gas testing, the sensor exhibited the highest response toward NH 3, while still exhibiting reasonably high sensitivity toward other interferent gases. We tested the sensor in a high-flow reactor at the National Transportation Research Center (NTRC) in order to simulate exhaust gas constituents and flow rates produced by lean-burn vehicles powered by Compression-Ignition Direct-Injection (CIDI), diesel engines. The sensor wasmore » characterized at 525 and 625°C for NH 3, CO, C 3H 6, C 3H 8, and NO x in a base gas composition of 10% O 2, 5% H 2O, and 5% CO 2 flowing at 15 slpm. The sensor exhibited fast response time equal to the response time of the system's switching valve (T90<0.6s). Furthermore, in simulations of overdosing a selective catalytic reduction (SCR) system, the sensor was able to selectively respond to 20ppm injections of NH 3 slip despite the presence of the interferent gas species at combined concentrations ten times higher than that of the NH 3. The laboratory sensor construct was transitioned to a pre-commercial, automotive stick sensor configuration that was demonstrated to retain the advantageous characteristics of the tape-cast device.« less
Response Characteristics of a Stable Mixed Potential Ammonia Sensor in Simulated Diesel Exhaust
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramaiyan, Kannan P.; Pihl, Josh A.; Kreller, Cortney R.
A mixed potential sensor using Au and Pt dense wire electrodes embedded between tape-casted layers of 8 mol% yttria stabilized zirconia (YSZ) was tested for application toward NH 3, NO, NO 2, C 3H 6 and C 3H 8. In single-gas testing, the sensor exhibited the highest response toward NH 3, while still exhibiting reasonably high sensitivity toward other interferent gases. We tested the sensor in a high-flow reactor at the National Transportation Research Center (NTRC) in order to simulate exhaust gas constituents and flow rates produced by lean-burn vehicles powered by Compression-Ignition Direct-Injection (CIDI), diesel engines. The sensor wasmore » characterized at 525 and 625°C for NH 3, CO, C 3H 6, C 3H 8, and NO x in a base gas composition of 10% O 2, 5% H 2O, and 5% CO 2 flowing at 15 slpm. The sensor exhibited fast response time equal to the response time of the system's switching valve (T90<0.6s). Furthermore, in simulations of overdosing a selective catalytic reduction (SCR) system, the sensor was able to selectively respond to 20ppm injections of NH 3 slip despite the presence of the interferent gas species at combined concentrations ten times higher than that of the NH 3. The laboratory sensor construct was transitioned to a pre-commercial, automotive stick sensor configuration that was demonstrated to retain the advantageous characteristics of the tape-cast device.« less
ERIC Educational Resources Information Center
Namdar, Sara; Bagheri, Mohammad Sadegh
2012-01-01
Speaking proceeds under the constraint of time. While speaking, speakers are under constant pressure to follow the message being received and to formulate rapid responses to their partners. In the IELTS (International English Language Testing System) Speaking Test, the communicative nature of the interview creates an ideal situation for applicants…
Modeling Ballistic Response of Ultra-High-Molecular-Weight Polyethylene (UHMWPE)
2016-07-01
posttest panels. Fig. 5 Variables to be compared between model and experiments The 6 tests and available test data are listed in Table 2. The first 3...Time history of center BFD for the 3 BFD tests Figure 24 shows the damages in the panels from posttest CT scan of the UHMWPE panels and the
NREL Research Proves Wind Can Provide Ancillary Grid Fault Response | News
controllable grid interface (CGI) test facility, which simulates the real-time conditions of a utility-scale power grid. This began an ongoing, Energy Department-funded research effort to test how wind turbines test their equipment under any possible grid fault condition. Researchers such as Mark McDade, project
Two Versions of "Common" Test Eyed
ERIC Educational Resources Information Center
Gewertz, Catherine
2012-01-01
An unprecedented assessment project involving half the states is planning a significant shift: Instead of designing one test for all of them, it will offer a choice of a longer and a shorter version. The pivot came in response to some states' resistance to spending more time and money on testing for the common standards. The plan under discussion…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-27
... recordkeeping of self-testing subject to the regulation would affect 1,375 firms, with an average annual burden... of any corrective action as a result of self-testing would affect 10% of them, i.e., 138 firms, with... minute of skilled technical time. Recordkeeping for the self-test responsibility and of any corrective...
Ansai, Satoshi; Hosokawa, Hiroshi; Maegawa, Shingo; Kinoshita, Masato
2016-04-15
Medaka (Oryzias latipes) is a small freshwater teleost that is an emerging model system for neurobehavioral research and toxicological testing. The selective serotonin reuptake inhibitor class of antidepressants such as fluoxetine is one of the widely prescribed drugs, but little is known about the effects of these drugs on medaka behaviors. To assess the behavioral effects of fluoxetine, we chronically administrated fluoxetine to medaka adult fish and analyzed the anxiety-related and social behaviors using five behavioral paradigms (diving, open-field, light-dark transition, mirror-biting, and social interaction) with an automated behavioral testing system. Fish chronically treated with fluoxetine exhibited anxiolytic responses such as an overall increased time spent in the top area in the diving test and an increased time spent in center area in the open-field test. Analysis of socially evoked behavior showed that chronic fluoxetine administration decreased the number of mirror biting times in the mirror-biting test and increased latency to first contact in the social interaction test. Additionally, chronic fluoxetine administration reduced the horizontal locomotor activity in the open-field test but not the vertical activity in the diving test. These investigations are mostly consistent with previous reports in the other teleost species and rodent models. These results indicate that behavioral assessment in medaka adult fish will become useful for screening of effects of pharmaceutical and toxicological compounds in animal behaviors. Copyright © 2016 Elsevier B.V. All rights reserved.
The Phenylephrine Test Revisited.
Barsegian, Arpine; Botwinick, Adam; Reddy, Harsha S
To characterize the phenylephrine test in ptotic patients to help clinicians perform the test more efficiently. Adults with involutional ptosis (n = 24, 30 eyes) were assessed with digital photographs for response to topical 2.5% phenylephrine drop instillation. Patient characteristics (age, gender, iris color, dermatochalasis, brow ptosis, and baseline marginal reflex distance-1 [MRD-1] height) were recorded. From the photographs, change in (MRD-1), presence of conjunctival blanching, pupillary dilation, and Hering effect were recorded at specified time intervals, 1 minute to 1 hour after drop placement. Correlations between patient characteristics and measured outcomes were evaluated using analysis of variance, Pearson coefficient, or chi-square tests. The authors found that 73% of eyes had eyelid elevation with phenylephrine. Of these, 50% reached maximal eyelid elevation by 5 minutes, and 86% by 10 minutes after drop placement, but 14% did not reach maximal MRD-1 until 30 minutes. There is a negative correlation between the maximum MRD-1 and the baseline MRD-1 eyelid height (r = -0.5330, p < 0.01). There is no significant relationship between time to pupillary dilation with either time to max eyelid elevation or max eyelid elevation. No patient characteristic studied affected the likelihood of eyelid response to phenylephrine or presence of Hering effect. Although most ptotic eyelids demonstrate a response to 2.5% phenylephrine within 10 minutes, there is a subset of patients that respond much later. More ptotic eyelids had greater eyelid elevation with phenylephrine. Pupillary dilation and conjunctival blanching are neither predictive of nor temporally associated with eyelid height elevation. The authors did not identify any patient factors (e.g., dermatochalasis, brow ptosis) that can predict the likelihood of response to phenylephrine.
NASA Astrophysics Data System (ADS)
Troncossi, M.; Di Sante, R.; Rivola, A.
2016-10-01
In the field of vibration qualification testing, random excitations are typically imposed on the tested system in terms of a power spectral density (PSD) profile. This is the one of the most popular ways to control the shaker or slip table for durability tests. However, these excitations (and the corresponding system responses) exhibit a Gaussian probability distribution, whereas not all real-life excitations are Gaussian, causing the response to be also non-Gaussian. In order to introduce non-Gaussian peaks, a further parameter, i.e., kurtosis, has to be controlled in addition to the PSD. However, depending on the specimen behaviour and input signal characteristics, the use of non-Gaussian excitations with high kurtosis and a given PSD does not automatically imply a non-Gaussian stress response. For an experimental investigation of these coupled features, suitable measurement methods need to be developed in order to estimate the stress amplitude response at critical failure locations and consequently evaluate the input signals most representative for real-life, non-Gaussian excitations. In this paper, a simple test rig with a notched cantilevered specimen was developed to measure the response and examine the kurtosis values in the case of stationary Gaussian, stationary non-Gaussian, and burst non-Gaussian excitation signals. The laser Doppler vibrometry technique was used in this type of test for the first time, in order to estimate the specimen stress amplitude response as proportional to the differential displacement measured at the notch section ends. A method based on the use of measurements using accelerometers to correct for the occasional signal dropouts occurring during the experiment is described. The results demonstrate the ability of the test procedure to evaluate the output signal features and therefore to select the most appropriate input signal for the fatigue test.
78 FR 3407 - Proposed Information Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-16
... technical assistance programs by administering pre- and post-test instruments to participants. CNCS will.... Frequency: Annually. Average Time Per Response: Five minutes for the pre-test and 5 minutes for the post... analysis of client satisfaction feedback with aggregations of post training-participant evaluations...
Laboratory Surge Response to Pandemic (H1N1) 2009 Outbreak, New York City Metropolitan Area, USA
Crawford, James M.; Stallone, Robert; Zhang, Fan; Gerolimatos, Mary; Korologos, Diamanto D.; Sweetapple, Carolyn; de Geronimo, Marcella; Dlugacz, Yosef; Armellino, Donna M.
2010-01-01
The North Shore–Long Island Jewish Health System Laboratories serve 15 hospitals and affiliated regional physician practices in the New York City metropolitan area, with virus testing performed at a central reference laboratory. The influenza A pandemic (H1N1) 2009 outbreak began in this area on April 24, 2009, and within weeks respiratory virus testing increased 7.5 times. In response, laboratory and client service workforces were increased, physical plant build-out was completed, testing paradigms were converted from routine screening tests and viral culture to a high-capacity molecular assay for respiratory viruses, laboratory information system interfaces were built, and same-day epidemiologic reports were produced. Daily review by leadership of data from emergency rooms, hospital facilities, and the Health System Laboratories enabled real-time management of unfolding events. The ability of System laboratories to rapidly increase to high-volume comprehensive diagnostics, including influenza A subtyping, provided key epidemiologic information for local and state public health departments. PMID:20031036
Laboratory surge response to pandemic (H1N1) 2009 outbreak, New York City metropolitan area, USA.
Crawford, James M; Stallone, Robert; Zhang, Fan; Gerolimatos, Mary; Korologos, Diamanto D; Sweetapple, Carolyn; de Geronimo, Marcella; Dlugacz, Yosef; Armellino, Donna M; Ginocchio, Christine C
2010-01-01
The North Shore-Long Island Jewish Health System Laboratories serve 15 hospitals and affiliated regional physician practices in the New York City metropolitan area, with virus testing performed at a central reference laboratory. The influenza A pandemic (H1N1) 2009 outbreak began in this area on April 24, 2009, and within weeks respiratory virus testing increased 7.5 times. In response, laboratory and client service workforces were increased, physical plant build-out was completed, testing paradigms were converted from routine screening tests and viral culture to a high-capacity molecular assay for respiratory viruses, laboratory information system interfaces were built, and same-day epidemiologic reports were produced. Daily review by leadership of data from emergency rooms, hospital facilities, and the Health System Laboratories enabled real-time management of unfolding events. The ability of System laboratories to rapidly increase to high-volume comprehensive diagnostics, including influenza A subtyping, provided key epidemiologic information for local and state public health departments.
American cutaneous leishmaniasis: use of a skin test as a predictor of relapse after treatment.
Passos, V. M.; Barreto, S. M.; Romanha, A. J.; Krettli, A. U.; Volpini, A. C.; Lima e Costa, M. F.
2000-01-01
While relapses following clinical cure of American cutaneous leishmaniasis are frequent, no test has been described until now to predict such relapses. A cohort of 318 American cutaneous leishmaniasis patients was followed up for two years after treatment with meglumine antimoniate, during which time 32 relapses occurred, 30 in the first year and two in the second (accumulated risk: 10.5%). No association was found between these relapses and the parasite-specific antibody response before and after treatment, or between the relapses and stratification by sociodemographic and clinical characteristics. However when Leishmania was used as antigen, patients with a negative skin test at the time of diagnosis presented a 3.4-fold higher risk (hazard risk = 3.4; 95% confidence interval, 1.7-7.0) of American cutaneous leishmaniasis relapse, compared with patients with a positive response. This result shows that the skin test can be a predictor of American cutaneous leishmaniasis relapse after treatment. PMID:10994280
Verbal suppression and strategy use: a role for the right lateral prefrontal cortex?
Robinson, Gail A; Cipolotti, Lisa; Walker, David G; Biggs, Vivien; Bozzali, Marco; Shallice, Tim
2015-04-01
Verbal initiation, suppression and strategy generation/use are cognitive processes widely held to be supported by the frontal cortex. The Hayling Test was designed to tap these cognitive processes within the same sentence completion task. There are few studies specifically investigating the neural correlates of the Hayling Test but it has been primarily used to detect frontal lobe damage. This study investigates the components of the Hayling Test in a large sample of patients with unselected focal frontal (n = 60) and posterior (n = 30) lesions. Patients and controls (n = 40) matched for education, age and sex were administered the Hayling Test as well as background cognitive tests. The standard Hayling Test clinical measures (initiation response time, suppression response time, suppression errors and overall score), composite errors scores and strategy-based responses were calculated. Lesions were analysed by classical frontal/posterior subdivisions as well as a finer-grained frontal localization method and a specific contrast method that is somewhat analogous to voxel-based lesion mapping methods. Thus, patients with right lateral, left lateral and superior medial lesions were compared to controls and patients with right lateral lesions were compared to all other patients. The results show that all four standard Hayling Test clinical measures are sensitive to frontal lobe damage although only the suppression error and overall scores were specific to the frontal region. Although all frontal patients produced blatant suppression errors, a specific right lateral frontal effect was revealed for producing errors that were subtly wrong. In addition, frontal patients overall produced fewer correct responses indicative of developing an appropriate strategy but only the right lateral group showed a significant deficit. This problem in strategy attainment and implementation could explain, at least in part, the suppression error impairment. Contrary to previous studies there was no specific frontal effect for verbal initiation. Overall, our results support a role for the right lateral frontal region in verbal suppression and, for the first time, in strategy generation/use. © The Author (2015). Published by Oxford University Press on behalf of the Guarantors of Brain. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Gravitropic responses of plants in the absence of a complicating G-force (6-IML-1)
NASA Technical Reports Server (NTRS)
Brown, Allan H.
1992-01-01
On the Earth it is patently impossible to measure any tropistic, physiologic, or morphogenic reactions to environmental stimuli without taking into account our planet's gravitational influence on the time course of the test subject's response. It follows that all published reports of quantitative measurements of such responses must have been contaminated by an additional gravity dependent component which probably was not trivial. Our research effort has as its principal scientific objective, the acquisition of experimental data from tests in a microgravity environment that will address a number of basic questions about plants' gravitropic responses to the perception of transversely applied g forces in the hypogravity range, from essentially zero to unit g. Comparable tests on Earth but in the same flight hardware, referred to as the Gravitational Plant Physiology Facility (GPPF), will provide 1 g data for various useful comparisons. Four specific scientific questions are addressed.
A Method for Response Time Measurement of Electrosensitive Protective Devices.
Dźwiarek, Marek
1996-01-01
A great step toward the improvement of safety at work was made when electrosensitive protective devices (ESPDs) were applied to the protection of press and robot-assisted manufacturing system operators. The way the device is mounted is crucial. The parameters of ESPD mounting that ensure safe distance from the controlled dangerous zone are response time, sensitivity, and the dimensions of the detection zone. The proposed experimental procedure of response time measurement is realized in two steps, with a test piece penetrating the detection zone twice. In the first step, low-speed penetration (at a speed v m ) enables the detection zone border to be localized. In the second step of measurement, the probe is injected at a high speed V d . The actuator rod position is measured and when it is equal to the value L registered by the earlier measurements, counting time begins as well as the monitoring of the state of the equipment under test (EUT) output relays. After the state changes, time tp is registered. The experimental procedure is realized on a special experimental stand. Because the stand has been constructed for certification purposes, the design satisfies the requirements imposed by Polski Komitet Normalizacyjny (PKN, 1995). The experimental results prove the measurement error to be smaller than ± 0.6 ms.
Enginar, Nurhan; Yamantürk-Çelik, Pınar; Nurten, Asiye; Güney, Dilvin Berrak
2016-07-01
The antidepressant-induced reduction in immobility time in the forced swimming test may depend on memory impairment due to the drug's anticholinergic efficacy. Therefore, the present study evaluated learning and memory of the immobility response in rats after the pretest and test administrations of antidepressants having potent, comparatively lower, and no anticholinergic activities. Immobility was measured in the test session performed 24 h after the pretest session. Scopolamine and MK-801, which are agents that have memory impairing effects, were used as reference drugs for a better evaluation of the memory processes in the test. The pretest administrations of imipramine (15 and 30 mg/kg), amitriptyline (7.5 and 15 mg/kg), trazodone (10 mg/kg), fluoxetine (10 and 20 mg/kg), and moclobemide (10 and 20 mg/kg) were ineffective, whereas the pretest administrations of scopolamine (0.5 mg/kg) and MK-801 (0.1 mg/kg) decreased immobility time suggesting impaired "learning to be immobile" in the animals. The test administrations of imipramine (30 mg/kg), amitriptyline (15 mg/kg), moclobemide (10 mg/kg), scopolamine (0.5 and 1 mg/kg), and MK-801 (0.1 mg/kg) decreased immobility time, which suggested that the drugs exerted antidepressant activity or the animals did not recall that attempting to escape was futile. The test administrations of trazodone (10 mg/kg) and fluoxetine (10 and 20 mg/kg) produced no effect on immobility time. Even though the false-negative and positive responses made it somewhat difficult to interpret the findings, this study demonstrated that when given before the pretest antidepressants with or without anticholinergic activity seemed to be devoid of impairing the learning process in the test.
Bitter tastant responses in the amoeba Dictyostelium correlate with rat and human taste assays.
Cocorocchio, Marco; Ives, Robert; Clapham, David; Andrews, Paul L R; Williams, Robin S B
2016-01-01
Treatment compliance is reduced when pharmaceutical compounds have a bitter taste and this is particularly marked for paediatric medications. Identification of bitter taste liability during drug discovery utilises the rat in vivo brief access taste aversion (BATA) test which apart from animal use is time consuming with limited throughput. We investigated the suitability of using a simple, non-animal model, the amoeba Dictyostelium discoideum to investigate taste-related responses and particularly identification of compounds with a bitter taste liability. The effect of taste-related compounds on Dictyostelium behaviour following acute exposure (15 minutes) was monitored. Dictyostelium did not respond to salty, sour, umami or sweet tasting compounds, however, cells rapidly responded to bitter tastants. Using time-lapse photography and computer-generated quantification to monitor changes in cell membrane movement, we developed an assay to assess the response of Dictyostelium to a wide range of structurally diverse known bitter compounds and blinded compounds. Dictyostelium showed varying responses to the bitter tastants, with IC50 values providing a rank order of potency. Comparison of Dictyostelium IC50 values to those observed in response to a similar range of compounds in the rat in vivo brief access taste aversion test showed a significant (p = 0.0172) positive correlation between the two models, and additionally a similar response to that provided by a human sensory panel assessment test. These experiments demonstrate that Dictyostelium may provide a suitable model for early prediction of bitterness for novel tastants and drugs. Interestingly, a response to bitter tastants appears conserved from single-celled amoebae to humans.
2011-01-01
Background Several clinical measures of sensory and motor function are used alongside patient-rated questionnaires to assess outcomes of carpal tunnel decompression. However there is a lack of evidence regarding which clinical tests are most responsive to clinically important change over time. Methods In a prospective cohort study 63 patients undergoing carpal tunnel decompression were assessed using standardised clinician-derived and patient reported outcomes before surgery, at 4 and 8 months follow up. Clinical sensory assessments included: touch threshold with monofilaments (WEST), shape-texture identification (STI™ test), static two-point discrimination (Mackinnon-Dellon Disk-Criminator) and the locognosia test. Motor assessments included: grip and tripod pinch strength using a digital grip analyser (MIE), manual muscle testing of abductor pollicis brevis and opponens pollicis using the Rotterdam Intrinsic Handheld Myometer (RIHM). The Boston Carpal Tunnel Questionnaire (BCTQ) was used as a patient rated outcome measure. Results Relative responsiveness at 4 months was highest for the BCTQ symptom severity scale with moderate to large effects sizes (ES = -1.43) followed by the BCTQ function scale (ES = -0.71). The WEST and STI™ were the most responsive sensory tests at 4 months showing moderate effect sizes (WEST ES = 0.55, STI ES = 0.52). Grip and pinch strength had a relatively higher responsiveness compared to thenar muscle strength but effect sizes for all motor tests were very small (ES ≤0.10) or negative indicating a decline compared to baseline in some patients. Conclusions For clinical assessment of sensibility touch threshold assessed by monofilaments (WEST) and tactile gnosis measured with the STI™ test are the most responsive tests and are recommended for future studies. The use of handheld myometry (RIHM) for manual muscle testing, despite more specifically targeting thenar muscles, was less responsive than grip or tripod pinch testing using the digital grip analyser (MIE). When assessing power and pinch strength the effect of other concomitant conditions such as degenerative joint disease on strength needs to be considered. PMID:22032626
A comprehensive approach to predicting chronic toxicity from acute.toxicity data was developed in which simultaneous consideration is given to concentration, degree of response, and time course of effect. onsistent endpoint (lethality) and degree of response (O%) were used to com...
Analyzing Longitudinal Item Response Data via the Pairwise Fitting Method
ERIC Educational Resources Information Center
Fu, Zhi-Hui; Tao, Jian; Shi, Ning-Zhong; Zhang, Ming; Lin, Nan
2011-01-01
Multidimensional item response theory (MIRT) models can be applied to longitudinal educational surveys where a group of individuals are administered different tests over time with some common items. However, computational problems typically arise as the dimension of the latent variables increases. This is especially true when the latent variable…
McKay, Rachel Eshima; Hall, Kathryn T; Hills, Nancy
2016-02-01
Nonintubated patients receiving sevoflurane have slower protective airway reflex recovery after anesthesia compared with patients receiving desflurane. We asked whether this difference would remain significant among intubated patients receiving rocuronium or whether the impact of variable neuromuscular recovery would predominate and thus minimize differences between anesthetics. After obtaining written informed consent, patients were randomly assigned to receive sevoflurane (n = 41) or desflurane (n = 40), with neuromuscular monitoring by quantitative train-of-four (TOF) method using accelerometry. Intubation was facilitated by administration of 1 mg/kg rocuronium. Neuromuscular block was produced, with the goal of maintaining 10% to 15% of baseline function. After surgery, neostigmine 70 µg/kg + glycopyrrolate 14 µg/kg was administered. When TOF ratio reached ≥ 0.7, anesthetic was discontinued and fresh gas flow was raised to 15 L/m. The time of first response to command was noted, after which patients were given a 20-mL water swallowing test at 2, 6, 14, 22, 30, and 60 minutes. The following average time intervals were compared between the 2 intervention groups: anesthetic discontinuation to first response to command (T1); first response to command to first successful passing of swallow test (T2); and anesthetic discontinuation to first successful passing of swallow test (T3). We also compared the rates of successful swallow tests at 2 minutes after first response to command in the 2 groups, first categorizing as failures all those who were unable to take the test at 2 minutes, and then excluding 10 patients unable to take the test at this time for reasons other than somnolence (n = 10). Patients receiving desflurane passed the swallowing test at shorter time intervals after first response to command than did patients receiving sevoflurane (Wilcoxon-Mann-Whitney odds = 1.60; 95% confidence interval [CI], 1.01-2.69; P = 0.054). Two minutes after the first response to command, among all 81 patients, the chance of passing the swallowing test was higher after desflurane compared with sevoflurane anesthesia (relative risk = 1.6; 95% CI, 1.0-2.5; P = 0.04). Of the 71 patients (as above), we observed a significantly higher chance of passing at 2 minutes after first response to command (relative risk = 1.8; 95% CI, 1.2-2.7; P = 0.006) in patients receiving desflurane (25/33) compared with those receiving sevoflurane (16/38). In 18 of 81 and 16 of 71 patients, the neuromuscular monitoring and reversal protocols were not followed (neostigmine underdosed, extubation at TOF <0.7, or reliance on tactile as opposed to quantitative TOF measurement). In both the total cohort and the subset of 71, neuromuscular protocol adherence increased the chance of passing the swallow test, independent of anesthetic assignment in multivariable logistic regression (P = 0.02 and P = 0.006, respectively), demonstrating significant effect on airway reflex recovery independent of chosen anesthetic. Compared with sevoflurane, desflurane allowed faster recovery of airway reflexes after anesthesia in intubated patients. Clinical management of neuromuscular block, including full reversal and the use of quantitative TOF, affects airway reflex recovery-an effect that may be at least as profound as the choice of potent inhaled anesthetic.
Dynamic stability and handling qualities tests on a highly augmented, statically unstable airplane
NASA Technical Reports Server (NTRS)
Gera, Joseph; Bosworth, John T.
1987-01-01
This paper describes some novel flight tests and analysis techniques in the flight dynamics and handling qualities area. These techniques were utilized during the initial flight envelope clearance of the X-29A aircraft and were largely responsible for the completion of the flight controls clearance program without any incidents or significant delays. The resulting open-loop and closed-loop frequency responses and the time history comparison using flight and linear simulation data are discussed.
Schneid, Stephen D; Armour, Chris; Park, Yoon Soo; Yudkowsky, Rachel; Bordage, Georges
2014-10-01
Despite significant evidence supporting the use of three-option multiple-choice questions (MCQs), these are rarely used in written examinations for health professions students. The purpose of this study was to examine the effects of reducing four- and five-option MCQs to three-option MCQs on response times, psychometric characteristics, and absolute standard setting judgements in a pharmacology examination administered to health professions students. We administered two versions of a computerised examination containing 98 MCQs to 38 Year 2 medical students and 39 Year 3 pharmacy students. Four- and five-option MCQs were converted into three-option MCQs to create two versions of the examination. Differences in response time, item difficulty and discrimination, and reliability were evaluated. Medical and pharmacy faculty judges provided three-level Angoff (TLA) ratings for all MCQs for both versions of the examination to allow the assessment of differences in cut scores. Students answered three-option MCQs an average of 5 seconds faster than they answered four- and five-option MCQs (36 seconds versus 41 seconds; p = 0.008). There were no significant differences in item difficulty and discrimination, or test reliability. Overall, the cut scores generated for three-option MCQs using the TLA ratings were 8 percentage points higher (p = 0.04). The use of three-option MCQs in a health professions examination resulted in a time saving equivalent to the completion of 16% more MCQs per 1-hour testing period, which may increase content validity and test score reliability, and minimise construct under-representation. The higher cut scores may result in higher failure rates if an absolute standard setting method, such as the TLA method, is used. The results from this study provide a cautious indication to health professions educators that using three-option MCQs does not threaten validity and may strengthen it by allowing additional MCQs to be tested in a fixed amount of testing time with no deleterious effect on the reliability of the test scores. © 2014 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Argueello, J.G.; Dohrmann, C.R.; Carne, T.G.
The combined analysis/test effort described in this paper compares predictions with measured data from a step-relaxation test in the absence of significant wind-driven aerodynamic loading. The process described here is intended to illustrate a method for validation of time domain codes for structural analysis of wind turbine structures. Preliminary analyses were performed to investigate the transient dynamic response that the rotating Sandia 34 m Vertical Axis Wind Turbine (VAWT) would undergo when one of the two blades was excited by step-relaxation. The calculations served two purposes. The first was for pretest planning to evaluate the relative importance of the variousmore » forces that would be acting on the structure during the test and to determine if the applied force in the step-relaxation would be sufficient to produce an excitation that was distinguishable from that produced by the aerodynamic loads. The second was to provide predictions that could subsequently be compared to the data from the test. The test was carried out specifically to help in the validation of the time-domain structural dynamics code, VAWT-SDS, which predicts the dynamic response of VAWTs subject to transient events. Post-test comparisons with the data were performed and showed a qualitative agreement between pretest predictions and measured response. However, they also showed that there was significantly more damping in the measurements than included in the predictions. Efforts to resolve this difference, including post-test analyses, were undertaken and are reported herein. The overall effort described in this paper represents a major step in the process of arriving at a validated structural dynamics code.« less
Imanaka, A; Morinobu, S; Toki, S; Yamamoto, S; Matsuki, A; Kozuru, T; Yamawaki, S
2008-01-10
It is well known that early life events induce long-lasting psychophysiological and psychobiological influences in later life. In rodent studies, environmental enrichment after weaning prevents the adulthood behavioral and emotional disturbances in response to early adversities. We compared the behavioral effect of neonatal isolation (NI) with the effect of NI accompanied by tactile stimulation (NTS) to determine whether NTS could reverse or prevent the effects of NI on the adulthood behavioral and emotional responses to environmental stimuli. In addition, we also examined the sex difference of the NTS effect. Measurements of body weights, an open-field locomotor test, an elevated plus maze test, a hot-plate test, and a contextual fear-conditioning test were performed on postnatal day 60. As compared with rats subjected to NI, rats subjected to NTS showed significantly higher activity and exploration in the open-field locomotor test, lower anxiety-like behavior in the elevated plus maze test, and significantly prolonged latencies in the hot-plate test, and this effect was equal among males and females. In the contextual fear-conditioning test, whereas NTS significantly reduced the enhanced freezing time due to NI in females, no significant difference in the freezing time between NI and NTS was found in males. These findings indicate that adequate tactile stimulation in early life plays an important role in the prevention of disturbances in the behavioral and emotional responses to environmental stimuli in adulthood induced by early adverse experiences.
Fast logic?: Examining the time course assumption of dual process theory.
Bago, Bence; De Neys, Wim
2017-01-01
Influential dual process models of human thinking posit that reasoners typically produce a fast, intuitive heuristic (i.e., Type-1) response which might subsequently be overridden and corrected by slower, deliberative processing (i.e., Type-2). In this study we directly tested this time course assumption. We used a two response paradigm in which participants have to give an immediate answer and afterwards are allowed extra time before giving a final response. In four experiments we used a range of procedures (e.g., challenging response deadline, concurrent load) to knock out Type 2 processing and make sure that the initial response was intuitive in nature. Our key finding is that we frequently observe correct, logical responses as the first, immediate response. Response confidence and latency analyses indicate that these initial correct responses are given fast, with high confidence, and in the face of conflicting heuristic responses. Findings suggest that fast and automatic Type 1 processing also cues a correct logical response from the start. We sketch a revised dual process model in which the relative strength of different types of intuitions determines reasoning performance. Copyright © 2016 Elsevier B.V. All rights reserved.
Ferreira, Amanda M J; Farias-Junior, Luiz F; Mota, Thaynan A A; Elsangedy, Hassan M; Marcadenti, Aline; Lemos, Telma M A M; Okano, Alexandre H; Fayh, Ana P T
2018-01-01
The hypothesis of the central effect of carbohydrate mouth rinse (CMR) on performance improvement in a fed state has not been established, and its psychophysiological responses have not yet been described. The aim of this study was to evaluate the effect of CMR in athletes fed state on performance, biochemical and psychophysiological responses compared to ad libitum water intake. Eleven trained male cyclists completed a randomized, crossover trial, which consisted of a 30 km cycle ergometer at self-selected intensity and in a fed state. Subjects were under random influence of the following interventions: CMR with a 6% unflavored maltodextrin solution; mouth rinsing with a placebo solution (PMR); drinking "ad libitum" (DAL). The time for completion of the test (min), heart rate (bpm) and power (watts), rating of perceived exertion (RPE), affective response, blood glucose (mg/dL) and lactate (mmol/DL), were evaluated before, during and immediately after the test, while insulin (uIL/mL), cortisol (μg/dL) and creatine kinase (U/L) levels were measured before, immediately after the test and 30 min after the test. Time for completion of the 30 km trial did not differ significantly among CMR, PMR and DAL interventions (means = 54.5 ± 2.9, 54.7 ± 2.9 and 54.5 ± 2.5 min, respectively; p = 0.82). RPE and affective response were higher in DAL intervention ( p < 0.01). Glucose, insulin, cortisol and creatine kinase responses showed no significant difference among interventions. In a fed state, CMR has not caused metabolic changes, and it has not improved physical performance compared to ad libitum water intake, but demonstrated a possible central effect. ReBec registration number: RBR-4vpwkg. Available in http://www.ensaiosclinicos.gov.br/rg/?q=RBR-4vpwkg.
Lin, Mau-Roung; Hwang, Hei-Fen; Hu, Ming-Hsia; Wu, Hong-Dar Isaac; Wang, Yi-Wei; Huang, Fu-Chao
2004-08-01
To compare the practicality, reliability, validity, and responsiveness of the timed up and go (TUG), one-leg stand (OLS), functional reach (FR), and Tinetti balance (TB) performance measures in people aged 65 and older. A prospective study. Shin-Sher Township of Taichung County, west-central Taiwan. Twelve hundred community-dwelling older people. During an initial assessment at their residences, participants were interviewed for demographics, cognition, fall history, use of a walking aid, and activities of daily living (ADLs), in addition to completing the four balance tests. Falls were ascertained by telephone every 3 months for a 1-year follow-up; the four balance measures and ADLs were also reassessed at the end of the follow-up year. Of the four balance measures, the OLS had the lowest participation rate, and participation of people who were cognitively impaired had fallen in the previous year, used a walking aid, or suffered from an ADL disability was lower than for their counterparts. The time to complete the tests ranged from 58 seconds for OLS, to 160 seconds for the TB. All four balance measures exhibited excellent test-retest reliability and discriminant validity but poor responsiveness to fall status. The TB showed better discriminant, convergent, and predictive validities and responsiveness to ADL changes than the other three tests. According to psychometric properties, the most suitable performance measure for evaluating balance in community-dwelling older people was the TB, followed by the TUG.
Second Language Interference during First Language Processing by Arabic–English Bilinguals
Alsaigh, Tahani; Kennison, Shelia M.
2017-01-01
The research investigated whether a bilinguals’ second language (L2) is activated during a task involving only the first language (L1). We tested the hypothesis that the amount of L2 interference can vary across settings, with less interference occurring in testing locations where L2 is rarely used. In Experiment 1, we compared language processing for 50 Arabic–English bilinguals tested in Saudi Arabia and 49 Arabic–English tested in the United States. In the task, participants viewed a picture and judged whether a phoneme presented over headphones was part of the L1 picture name. The results showed no effect of testing location on processing. For both groups of bilinguals, we observed L2 interference in mean error rates, but not in mean response times. We also found evidence for L2 interference in correlational analyses between response times and (a) participants’ weekly L2 usage and (b) frequency of English picture names. A second experiment with 24 Arabic monolinguals supported the conclusion that the results with bilinguals were due to L2 interference. Implications for theories of bilingual memory are discussed. PMID:29163322
Aloui, K; Abedelmalek, S; Chtourou, H; Wong, D P; Boussetta, N; Souissi, N
2017-03-01
The aim of this study was to investigate the effect of time-of-day on oxidative stress, cardiovascular parameters, muscle damage parameters, and hormonal responses following the level-1 Yo-Yo intermittent recovery test (YYIRT). A total of 11 healthy subjects performed an intermittent test (YYIRT) at two times-of-day (i.e., 07:00 h and 17:00 h), with a recovery period of ≥36 h in-between, in a randomized order. Blood samples were taken at the rest (baseline) and immediately (post-YYIRT) after the YYIRT for measuring oxidative stress, biochemical markers, and hormonal response. Data were statistically analyzed using one-way and two-way repeated measures ANOVA and Bonferroni test at p < 0.05. Observed power (α = 0.05) and partial eta-squared were used. Our results showed that oxygen uptake (VO 2max ), maximal aerobic speed, and the total distance covered tended to be higher in the evening (17:00 h). There was also a main effect of time-of-day for cortisol and testosterone concentration, which were higher after the YYIRT in the morning (p < 0.05). The heart rate peak and the rating of perceived exertion scales were lower in the morning (p < 0.05). However, the plasma glucose (p < 0.01), malondialdehyde, creatine kinase (p < 0.01), lactate dehydrogenase (p < 0.05), high-density lipoprotein (p < 0.01), total cholesterol (p < 0.01), and triglycerides (p < 0.05) were higher after the YYIRT in the evening. Low-density lipoprotein, systolic blood pressure, diastolic blood pressure, and lactate levels (p > 0.05) were similar for the morning and evening test. In conclusion, our findings suggest that aerobic performance presents diurnal variation with great result observed in the evening accompanied by an improvement of hormonal, metabolic, and oxidative responses. These data may help to guide athletes and coaches and contribute to public health recommendations on exercise and muscle damage particularly in the competitive periods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chakraborty, Sudipta; Nelson, Austin; Hoke, Anderson
2016-12-12
Traditional testing methods fall short in evaluating interactions between multiple smart inverters providing advanced grid support functions due to the fact that such interactions largely depend on their placements on the electric distribution systems with impedances between them. Even though significant concerns have been raised by the utilities on the effects of such interactions, little effort has been made to evaluate them. In this paper, power hardware-in-the-loop (PHIL) based testing was utilized to evaluate autonomous volt-var operations of multiple smart photovoltaic (PV) inverters connected to a simple distribution feeder model. The results provided in this paper show that depending onmore » volt-var control (VVC) parameters and grid parameters, interaction between inverters and between the inverter and the grid is possible in some extreme cases with very high VVC slopes, fast response times and large VVC response delays.« less
Akpinar, Selçuk
2016-01-01
Previous research suggests that older persons show cognitive deficits in standardized laboratory tests, but not in more natural tests such as the Multiple Errands Task (MET). The absence of deficits in the latter tests has been attributed to the compensation of deficits by strategies based on life-long experience. To scrutinize this view, we primed older participants with positive or negative stereotypes about old age before administering MET. We found that compared to unprimed controls, priming with positive age stereotypes reduced the number of errors without changing response times, while priming with negative stereotypes changed neither errors not response times. We interpret our findings as evidence that positive age priming improved participants’ cognitive functions while leaving intact their experience-based compensation, and that negative age priming degraded participants’ cognitive functions which, however, was balanced by an even stronger experience-based compensation. PMID:27649296
Bock, Otmar; Akpinar, Selçuk
2016-01-01
Previous research suggests that older persons show cognitive deficits in standardized laboratory tests, but not in more natural tests such as the Multiple Errands Task (MET). The absence of deficits in the latter tests has been attributed to the compensation of deficits by strategies based on life-long experience. To scrutinize this view, we primed older participants with positive or negative stereotypes about old age before administering MET. We found that compared to unprimed controls, priming with positive age stereotypes reduced the number of errors without changing response times, while priming with negative stereotypes changed neither errors not response times. We interpret our findings as evidence that positive age priming improved participants' cognitive functions while leaving intact their experience-based compensation, and that negative age priming degraded participants' cognitive functions which, however, was balanced by an even stronger experience-based compensation.
NASA Astrophysics Data System (ADS)
Tanoto, Yopi Y.; Anggono, Juliana; Siahaan, Ian H.; Budiman, Wesley
2017-01-01
There are several parameters that must be set before manufacturing a product using 3D printing. These parameters include the orientation deposition of that product, type of material, form fill, fill density, and other parameters. The finished product of 3D printing has some responses that can be observed, measured, and tested. Some of those responses are the processing time, the dimensions of the end product, its surface roughness and the mechanical properties, i.e. its yield strength, ultimate tensile strength, and impact resistance. This research was conducted to study the relationship between process parameters of 3D printing machine using a technology of fused deposition modeling (FDM) and the generated responses. The material used was ABS plastic that was commonly used in the industry. Understanding the relationship between the parameters and the responses thus the resulting product can be manufactured to meet the user needs. Three different orientations in depositing the ABS polymer named XY(first orientation), YX (second orientation), and ZX (third orientation) were studied. Processing time, dimensional accuracy, and the product strength were the responses that were measured and tested. The study reports that the printing process with third orientation was the fastest printing process with the processing time 2432 seconds followed by orientation 1 and 2 with a processing time of 2688 and 2780 seconds respectively. Dimension accuracy was also measured from the width and the length of gauge area of tensile test specimens printed in comparison with the dimensions required by ASTM 638-02. It was found that the smallest difference was in thickness dimension, i.e. 0.1 mm thicker in printed sample using second orientation than as required by the standard. The smallest thickness deviation from the standard was measured in width dimension of a sample printed using first orientation (0.13 mm). As with the length dimension, the closest dimension to the standard was resulted from the third orientation product, i.e 0.2 mm. Tensile test done on all the specimens produced with those three orientations shows that the highest tensile strength was obtained in sample from second orientation deposition, i.e. 7.66 MPa followed by the first and third orientations products, i.e. 6.8 MPa and 3.31 MPa, respectively.
A voltage to frequency converter for astronomical photometry
NASA Technical Reports Server (NTRS)
Dunham, E.; Elliot, J. L.
1978-01-01
A voltage to frequency converter (VFC) for general use with photomultipliers is described. For high light levels, when the dead-time corrections for a photon counter would be excessive, the VFC maintains a linear response and allows the recording of data at high time resolution. Results of laboratory tests are given for the signal-to-noise characteristics, linearity, stability, and transient response of the VFC when used in conjunction with EMI 9658 and RCA C31034 photomultipliers.
Population density and racial differences in the performance of emergency medical services.
David, Guy; Harrington, Scott E
2010-07-01
This paper analyzes the existence and scope of possible racial differences/disparities in the provision of emergency medical services (EMS) response capability (time from dispatch to arrival at the scene and level of training of the responding team) using data on approximately 120,000 cardiac incidents in the state of Mississippi during 1995-2004. The conceptual framework and empirical analysis focus on the likely effects of population density on the efficient production of EMS as a local public good subject to congestion, and on the need to control adequately for population density to avoid bias in testing for racial differences. Models that control for aggregate population density at the county-level indicate "reverse" disparities: faster estimated response times for African-Americans than for whites. When a refined county-level measure of population density is used that incorporates differences in African-American and white population density by Census tract, the reverse disparity in response times disappears. There also is little or no evidence of race-related differences in the certification level of EMS responders. However, there is evidence that, controlling for response time, African-Americans on average were significantly more likely to be deceased than whites upon EMS arrival at the scene. The overall results are germane to the debate over the scope of conditioning variables that should be included when testing for racial disparities in health care.
Dynamic response characteristics of two transport models tested in the National Transonic Facility
NASA Technical Reports Server (NTRS)
Young, Clarence P., Jr.
1993-01-01
This paper documents recent experiences with measuring the dynamic response characteristics of a commercial transport and a military transport model during full scale Reynolds number tests in the National Transonic Facility. Both models were limited in angle of attack while testing at full scale Reynolds number and cruise Mach number due to pitch or stall buffet response. Roll buffet (wing buzz) was observed for both models at certain Mach numbers while testing at high Reynolds number. Roll buffet was more severe and more repeatable for the military transport model at cruise Mach number. Miniature strain-gage type accelerometers were used for the first time for obtaining dynamic data as a part of the continuing development of miniature dynamic measurements instrumentation for cryogenic applications. This paper presents the results of vibration measurements obtained for both the commercial and military transport models and documents the experience gained in the use of miniature strain gage type accelerometers.
Acoustic testing of high temperature panels
NASA Technical Reports Server (NTRS)
Leatherwood, Jack D.; Clevenson, Sherman A.; Powell, Clemans A.; Daniels, Edward F.
1990-01-01
Results are presented of a series of thermal-acoustic tests conducted on the NASA Langley Research Center Thermal-Acoustic Test Apparatus to (1) investigate techniques for obtaining strain measurements on metallic and carbon-carbon materials at elevated temperature; (2) document the dynamic strain response characteristics of several superalloy honeycomb thermal protection system panels at elevated temperatures of up to 1200 F; and (3) determine the strain response and sonic fatigue behavior of four carbon-carbon panels at both ambient and elevated temperatures. A second study tested four carbon-carbon panels to document panel dynamic response characteristics at ambient and elevated temperature, determine time to failure and faliure modes, and collect continuous strain data up to panel failure. Strain data are presented from both types of panels, and problems encountered in obtaining reliable strain data on the carbon-carbon panels are described. The failure modes of the carbon-carbon panels are examined.
2010-01-01
Background Unilateral constrictive sciatic nerve injury (uCCI) is a common neuropathic pain model. However, the bilateral constrictive injury (bCCI) model is less well studied, and shows unique characteristics. In the present study, we sought to correlate effects of bCCI on nocifensive responses to cold and mechanical stimuli with selected dorsal horn anatomic markers. bCCI or sham ligation of both rat sciatic nerves were followed up to 90 days of behavioural testing. Additional rats sacrificed at 15, 30 and 90 days were used for anatomic analyses. Behavioural tests included hindpaw withdrawal responses to topical acetone, cold plate testing, an operant thermal preference task and hindpaw withdrawal thresholds to mechanical probing. Results All nocifensive responses to cold increased and remained enhanced for >45 days. Mechanical withdrawal thresholds decreased for 25 days only. Densitometric analyses of immunoperoxidase staining in the superficial dorsal horn at L4-5 revealed decreased cholecystokinin (CCK) staining at all times after bCCI, decreased mu opiate receptor (MOR) staining, maximal at 15 days, increased neuropeptide Y (NPY) staining only at days 15 and 30, and increased neurokinin-1 receptor (NK-1R) staining at all time points, maximal at 15 days. Correlation analyses at 45 days post-bCCI, were significant for individual rat nocifensive responses in each cold test and CCK and NK-1R, but not for MOR or NPY. Conclusions These results confirm the usefulness of cold testing in bCCI rats, a new approach using CCI to model neuropathic pain, and suggest a potential value of studying the roles of dorsal horn CCK and substance P in chronic neuropathic pain. Compared to human subjects with neuropathic pain, responses to cold stimuli in rats with bCCI may be a useful model of neuropathic pain. PMID:20105332
Datta, Sukdeb; Chatterjee, Koel; Kline, Robert H; Wiley, Ronald G
2010-01-27
Unilateral constrictive sciatic nerve injury (uCCI) is a common neuropathic pain model. However, the bilateral constrictive injury (bCCI) model is less well studied, and shows unique characteristics. In the present study, we sought to correlate effects of bCCI on nocifensive responses to cold and mechanical stimuli with selected dorsal horn anatomic markers. bCCI or sham ligation of both rat sciatic nerves were followed up to 90 days of behavioural testing. Additional rats sacrificed at 15, 30 and 90 days were used for anatomic analyses. Behavioural tests included hindpaw withdrawal responses to topical acetone, cold plate testing, an operant thermal preference task and hindpaw withdrawal thresholds to mechanical probing. All nocifensive responses to cold increased and remained enhanced for >45 days. Mechanical withdrawal thresholds decreased for 25 days only. Densitometric analyses of immunoperoxidase staining in the superficial dorsal horn at L4-5 revealed decreased cholecystokinin (CCK) staining at all times after bCCI, decreased mu opiate receptor (MOR) staining, maximal at 15 days, increased neuropeptide Y (NPY) staining only at days 15 and 30, and increased neurokinin-1 receptor (NK-1R) staining at all time points, maximal at 15 days. Correlation analyses at 45 days post-bCCI, were significant for individual rat nocifensive responses in each cold test and CCK and NK-1R, but not for MOR or NPY. These results confirm the usefulness of cold testing in bCCI rats, a new approach using CCI to model neuropathic pain, and suggest a potential value of studying the roles of dorsal horn CCK and substance P in chronic neuropathic pain. Compared to human subjects with neuropathic pain, responses to cold stimuli in rats with bCCI may be a useful model of neuropathic pain.
Luna, Fernando Gabriel; Marino, Julián; Roca, Javier; Lupiáñez, Juan
2018-05-20
Vigilance is generally understood as the ability to detect infrequent critical events through long time periods. In tasks like the Sustained Attention to Response Task (SART), participants tend to detect fewer events across time, a phenomenon known as "vigilance decrement". However, vigilance might also involve sustaining a tonic arousal level. In the Psychomotor Vigilance Test (PVT), the vigilance decrement corresponds to an increment across time in both mean and variability of reaction time. The present study aimed to develop a single task -Attentional Networks Test for Interactions and Vigilance - executive and arousal components (ANTI-Vea)- to simultaneously assess both components of vigilance (i.e., the executive vigilance as in the SART, and the arousal vigilance as in the PVT), while measuring the classic attentional functions (phasic alertness, orienting, and executive control). In Experiment #1, the executive vigilance decrement was found as an increment in response bias. In Experiment #2, this result was replicated, and the arousal vigilance decrement was simultaneously observed as an increment in reaction time. The ANTI-Vea solves some issues observed in the previous ANTI-V task with the executive vigilance measure (e.g., a low hit rate and no vigilance decrement). Furthermore, the new ANTI-Vea task assesses both components of vigilance together with others typical attentional functions. The new attentional networks test developed here may be useful to provide a better understanding of the human attentional system. The role of sensitivity and response bias in the executive vigilance decrement are discussed. Copyright © 2018 Elsevier B.V. All rights reserved.
2016-10-01
new version of the stimulator will be manufactured and tested again. This design-build-test cycle will be repeated multiple times during the second...AWARD NUMBER: W81XWH-15-C-0066 TITLE: Development of an Implantable Pudendal Nerve Stimulator To Restore Bladder Function in Humans After SCI...response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and
ERIC Educational Resources Information Center
Brosvic, Gary M.; Epstein, Michael L.; Cook, Michael J.; Dihoff, Roberta E.
2005-01-01
Participants completed 5 classroom examinations during which the timing of knowledge of results (no feedback: Scantron form; delayed feedback: end-of-test, 24 hour delay; immediate feedback: educator, response form) and iterative responding (1 response, up to 4 responses) were manipulated. At the end of the semester, each participant completed a…
Determination of the Proper Rest Time for a Cyclic Mental Task Using ACT-R Architecture.
Atashfeshan, Nooshin; Razavi, Hamideh
2017-03-01
Objective Analysis of the effect of mental fatigue on a cognitive task and determination of the right start time for rest breaks in work environments. Background Mental fatigue has been recognized as one of the most important factors influencing individual performance. Subjective and physiological measures are popular methods for analyzing fatigue, but they are restricted to physical experiments. Computational cognitive models are useful for predicting operator performance and can be used for analyzing fatigue in the design phase, particularly in industrial operations and inspections where cognitive tasks are frequent and the effects of mental fatigue are crucial. Method A cyclic mental task is modeled by the ACT-R architecture, and the effect of mental fatigue on response time and error rate is studied. The task includes visual inspections in a production line or control workstation where an operator has to check products' conformity to specifications. Initially, simulated and experimental results are compared using correlation coefficients and paired t test statistics. After validation of the model, the effects are studied by human and simulated results, which are obtained by running 50-minute tests. Results It is revealed that during the last 20 minutes of the tests, the response time increased by 20%, and during the last 12.5 minutes, the error rate increased by 7% on average. Conclusion The proper start time for the rest period can be identified by setting a limit on the error rate or response time. Application The proposed model can be applied early in production planning to decrease the negative effects of mental fatigue by predicting the operator performance. It can also be used for determining the rest breaks in the design phase without an operator in the loop.
Cardiorespiratory response to exercise testing in individuals with Alzheimer’s disease
Billinger, Sandra A.; Vidoni, Eric D.; Honea, Robyn A.; Burns, Jeffrey M.
2011-01-01
Objective To exercise testing in AD and possible disease-related change over time. Though physical activity and fitness are receiving increased attention as a possible adjunct treatment for Alzheimer’s disease (AD), relatively little work has been done characterizing their physiologic response to exercise Design Retrospective assessment of a 2-year, observational study Setting University medical center Participants 50 nondemented individuals and 31 with AD Interventions None Main Outcome Measures Participants underwent a clinical dementia evaluation and performed an incremental exercise test using a treadmill and the modified Bruce protocol at baseline and at a two year follow-up. We examined oxygen consumption, minute ventilation, heart rate and ventilatory equivalents for oxygen and carbon dioxide at submaximal and peak exercise intensities to determine if the measures were different between groups or over time. Results AD and nondemented participants performed similarly at submaximal effort and both groups showed similar change in exercise response over 2 years. However, nondemented individuals had consistently higher values of oxygen consumption (p≤0.02) and minute ventilation at peak effort at baseline (p=0.003). Conclusions Individuals with AD demonstrate physiologic responses to submaximal exercise effort that are not significantly different than individuals without dementia. However, differences are apparent at the extreme of effort. PMID:22133248
Ferraresi, Cleber; de Sousa, Marcelo Victor Pires; Huang, Ying-Ying; Bagnato, Vanderlei Salvador; Parizotto, Nivaldo Antonio; Hamblin, Michael R
2015-05-01
Recently, low-level laser (light) therapy has been used to increase muscle performance in intense exercises. However, there is a lack of understanding of the time response of muscles to light therapy. The first purpose of this study was to determine the time response for light-emitting diode therapy (LEDT)-mediated increase in adenosine triphosphate (ATP) in the soleus and gastrocnemius muscles in mice. Second purpose was to test whether LEDT can increase the resistance of muscles to fatigue during intense exercise. Fifty male Balb/c mice were randomly allocated into two equal groups: LEDT-ATP and LEDT-fatigue. Both groups were subdivided into five equal subgroups: LEDT-sham, LEDT-5 min, LEDT-3 h, LEDT-6 h, and LEDT-24 h. Each subgroup was analyzed for muscle ATP content or fatigue at specified time after LEDT. The fatigue test was performed by mice repeatedly climbing an inclined ladder bearing a load of 150 % of body weight until exhaustion. LEDT used a cluster of LEDs with 20 red (630 ± 10 nm, 25 mW) and 20 infrared (850 ± 20 nm, 50 mW) delivering 80 mW/cm(2) for 90 s (7.2 J/cm(2)) applied to legs, gluteus, and lower back muscles. LEDT-6 h was the subgroup with the highest ATP content in soleus and gastrocnemius compared to all subgroups (P < 0.001). In addition, mice in LEDT-6 h group performed more repetitions in the fatigue test (P < 0.001) compared to all subgroups: LEDT-sham and LEDT-5 min (~600 %), LEDT-3 h (~200 %), and LEDT-24 h (~300 %). A high correlation between the fatigue test repetitions and the ATP content in soleus (r = 0.84) and gastrocnemius (r = 0.94) muscles was observed. LEDT increased ATP content in muscles and fatigue resistance in mice with a peak at 6 h. Although the time response in mice and humans is not the same, athletes might consider applying LEDT at 6 h before competition.
Signal Processing Methods for Liquid Rocket Engine Combustion Stability Assessments
NASA Technical Reports Server (NTRS)
Kenny, R. Jeremy; Lee, Erik; Hulka, James R.; Casiano, Matthew
2011-01-01
The J2X Gas Generator engine design specifications include dynamic, spontaneous, and broadband combustion stability requirements. These requirements are verified empirically based high frequency chamber pressure measurements and analyses. Dynamic stability is determined with the dynamic pressure response due to an artificial perturbation of the combustion chamber pressure (bomb testing), and spontaneous and broadband stability are determined from the dynamic pressure responses during steady operation starting at specified power levels. J2X Workhorse Gas Generator testing included bomb tests with multiple hardware configurations and operating conditions, including a configuration used explicitly for engine verification test series. This work covers signal processing techniques developed at Marshall Space Flight Center (MSFC) to help assess engine design stability requirements. Dynamic stability assessments were performed following both the CPIA 655 guidelines and a MSFC in-house developed statistical-based approach. The statistical approach was developed to better verify when the dynamic pressure amplitudes corresponding to a particular frequency returned back to pre-bomb characteristics. This was accomplished by first determining the statistical characteristics of the pre-bomb dynamic levels. The pre-bomb statistical characterization provided 95% coverage bounds; these bounds were used as a quantitative measure to determine when the post-bomb signal returned to pre-bomb conditions. The time for post-bomb levels to acceptably return to pre-bomb levels was compared to the dominant frequency-dependent time recommended by CPIA 655. Results for multiple test configurations, including stable and unstable configurations, were reviewed. Spontaneous stability was assessed using two processes: 1) characterization of the ratio of the peak response amplitudes to the excited chamber acoustic mode amplitudes and 2) characterization of the variability of the peak response's frequency over the test duration. This characterization process assists in evaluating the discreteness of a signal as well as the stability of the chamber response. Broadband stability was assessed using a running root-mean-square evaluation. These techniques were also employed, in a comparative analysis, on available Fastrac data, and these results are presented here.
Relationships Between Gum Chewing and Stroop Test: A Pilot Study.
Kawakami, Y; Takeda, T; Konno, M; Suzuki, Y; Kawano, Y; Ozawa, T; Kondo, Y; Sakatani, K
2017-01-01
Cognitive function tends to decrease with aging, therefore maintenance of this function in an aging society is an important issue. The role of chewing in nutrition is important. Although several studies indicate that gum chewing is thought to improve cognitive function, it remains debatable whether gum-chewing does in fact improve cognitive function. The Stroop test is a psychological tool used to measure cognition. A shorter reaction time indicates a mean higher behavioral performance and higher levels of oxy-Hb concentration. fNIRS is a powerful, non-invasive imaging technique offering many advantages, including compact size, no need for specially equipped facilities, and the potential for real-time measurement. The left dorsolateral prefrontal cortex (DLPFC) seems to be mainly involved in the Stroop task.The aim of the present study was to investigate the hypothesis that gum-chewing changes cerebral blood flow in the left DLPFC during the Stroop test, and also changes the reaction time. Fourteen healthy volunteers (mean age 26.9 years) participated in this study after providing written informed consent. A piece of tasteless gum weighing 1.0 g was used. Each session was designed in a block manner, i.e. 4 rests (30 s) and 3 blocks of task (30 s). A computerized Stroop test was used (including both congruent and incongruent Stroop tasks) which calculates a response time automatically. The Binominal test was used for comparisons (p < 0.05). The results show activation of the left DLPFC during the Stroop task and that gum chewing significantly increases responses/oxy-Hb concentration and significantly shortens the reaction time.
Waning of vaccine-induced immunity to measles in kidney transplanted children.
Rocca, Salvatore; Santilli, Veronica; Cotugno, Nicola; Concato, Carlo; Manno, Emma Concetta; Nocentini, Giulia; Macchiarulo, Giulia; Cancrini, Caterina; Finocchi, Andrea; Guzzo, Isabella; Dello Strologo, Luca; Palma, Paolo
2016-09-01
Vaccine-preventable diseases are a significant cause of morbidity and mortality in solid organ transplant recipients who undergo immunosuppression after transplantation. Data on immune responses and long-term maintenance after vaccinations in such population are still limited.We cross-sectionally evaluated the maintenance of immune response to measles vaccine in kidney transplanted children on immunosuppressive therapy. Measles-specific enzyme-linked immunosorbent assay and B-cell enzyme-linked immunosorbent spot were performed in 74 kidney transplant patients (Tps) and in 23 healthy controls (HCs) previously vaccinated and tested for humoral protection against measles. The quality of measles antibody response was measured by avidity test. B-cell phenotype, investigated via flow cytometry, was further correlated to the ability of Tps to maintain protective humoral responses to measles over time.We observed the loss of vaccine-induced immunity against measles in 19% of Tps. Nonseroprotected children showed signs of impaired B-cell distribution as well as immune senescence and lower antibody avidity. We further reported as time elapsed between vaccination and transplantation, as well as the vaccine administration during dialysis are clinical factors affecting the maintenance of the immune memory response against measles.Tps present both quantitative and qualitative alterations in the maintenance of protective immunity to measles vaccine. Prospective studies are needed to optimize the vaccination schedules in kidney transplant recipients in order to increase the immunization coverage over time in this population.
VO2 responses to intermittent swimming sets at velocity associated with VO2max.
Libicz, Sebastien; Roels, Belle; Millet, Gregoire P
2005-10-01
While the physiological adaptations following endurance training are relatively well understood, in swimming there is a dearth of knowledge regarding the metabolic responses to interval training (IT). The hypothesis tested predicted that two different endurance swimming IT sets would induce differences in the total time the subjects swam at a high percentage of maximal oxygen consumption (VO(2)max). Ten trained triathletes underwent an incremental test to exhaustion in swimming so that the swimming velocity associated with VO(2)max (vVO(2)max) could be determined. This was followed by a maximal 400-m test and two intermittent sets at vVO(2)max: (a) 16 x 50 m with 15-s rest (IT(50)); (b) 8 x 100 m with 30-s rest (IT(100)). The times sustained above 95% VO(2)max (68.50 +/- 62.69 vs. 145.01 +/- 165.91 sec) and 95% HRmax (146.67 +/- 131.99 vs. 169.78 +/- 203.45 sec, p = 0.54) did not differ between IT(50) and IT(100)(values are mean +/- SD). In conclusion, swimming IT sets of equal time duration at vVO(2)max but of differing work-interval durations led to slightly different VO(2)and HR responses. The time spent above 95% of VO(2)max was twice as long in IT(100) as in IT (50), and a large variability between mean VO(2)and HR values was also observed.
Optimizing DER Participation in Inertial and Primary-Frequency Response
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dall-Anese, Emiliano; Zhao, Changhong; Guggilam, Swaroop
This paper develops an approach to enable the optimal participation of distributed energy resources (DERs) in inertial and primary-frequency response alongside conventional synchronous generators. Leveraging a reduced-order model description of frequency dynamics, DERs' synthetic inertias and droop coefficients are designed to meet time-domain performance objectives of frequency overshoot and steady-state regulation. Furthermore, an optimization-based method centered around classical economic dispatch is developed to ensure that DERs share the power injections for inertial- and primary-frequency response in proportion to their power ratings. Simulations for a modified New England test-case system composed of ten synchronous generators and six instances of the IEEEmore » 37-node test feeder with frequency-responsive DERs validate the design strategy.« less
Use of Lean Response to Improve Pandemic Influenza Surge in Public Health Laboratories
Chang, Yin; Prystajecky, Natalie; Petric, Martin; Mak, Annie; Abbott, Brendan; Paris, Benjamin; Decker, K.C.; Pittenger, Lauren; Guercio, Steven; Stott, Jeff; Miller, Joseph D.
2012-01-01
A novel influenza A (H1N1) virus detected in April 2009 rapidly spread around the world. North American provincial and state laboratories have well-defined roles and responsibilities, including providing accurate, timely test results for patients and information for regional public health and other decision makers. We used the multidisciplinary response and rapid implementation of process changes based on Lean methods at the provincial public health laboratory in British Columbia, Canada, to improve laboratory surge capacity in the 2009 influenza pandemic. Observed and computer simulating evaluation results from rapid processes changes showed that use of Lean tools successfully expanded surge capacity, which enabled response to the 10-fold increase in testing demands. PMID:22257385
Step-control of electromechanical systems
Lewis, Robert N.
1979-01-01
The response of an automatic control system to a general input signal is improved by applying a test input signal, observing the response to the test input signal and determining correctional constants necessary to provide a modified input signal to be added to the input to the system. A method is disclosed for determining correctional constants. The modified input signal, when applied in conjunction with an operating signal, provides a total system output exhibiting an improved response. This method is applicable to open-loop or closed-loop control systems. The method is also applicable to unstable systems, thus allowing controlled shut-down before dangerous or destructive response is achieved and to systems whose characteristics vary with time, thus resulting in improved adaptive systems.
Xu, Z M; De Vel, E; Vinck, B; Van Cauwenberge, P
1995-01-01
The effects of rise-fall and plateau times for the Pa component of the middle-latency response (MLR) were investigated in normally hearing subjects, and an objective MLR threshold was measured in patients with low- and middle-tone hearing losses, using a selected stimulus-envelope time. Our results showed that the stimulus-envelope time (the rise-fall time and plateau time groups) affected the Pa component of the MLR (quality was determined by the (chi 2-test and amplitude by the F-test). The 4-2-4 tone-pips produced good Pa quality by visual inspection. However, our data revealed no statistically significant Na-Pa amplitude differences between the two subgroups studied when comparing the 2- and 4-ms rise-fall times and the 0- and 2-ms plateau times. In contrast, Na-Pa became significantly smaller from the 4-ms to the 6-ms rise-fall time and from the 2-ms to the 4-ms plateau time (paired t-test). This result allowed us to select the 2- or 4-ms rise-fall time and the 0- or 2-ms plateau time without influencing amplitude. Analysis of the stimulus spectral characteristics demonstrated that a rise-fall time of at least 2ms could prevent spectral splatter and indicated that a stimulus with a 5-ms rise-fall time had a greater frequency-specificity than a stimulus of 2-ms rise-fall time. When considering the synchronous discharge and frequency-specificity of MLR, our findings show that a rise-fall time of four periods with a plateau of two periods is an acceptable compromise for estimating the objective MLR threshold.(ABSTRACT TRUNCATED AT 250 WORDS)
Reynolds, Jason; Rogers, Amber; Medellin, Eduardo; Guzman, Jonathan A; Watcha, Mehernoor F
2016-03-01
Dexmedetomidine is increasingly used by various routes for pediatric sedation. However, there are few randomized controlled trials comparing the efficacy of dexmedetomidine to other commonly used sedatives. To compare the efficacy of sedation with intranasal dexmedetomidine to oral chloral hydrate for auditory brainstem response (ABR) testing. In this double-blind, double-dummy study, children undergoing ABR testing were randomized to receive intranasal dexmedetomidine 3 mcg · kg(-1) plus oral placebo (Group IN DEX) or oral chloral hydrate 50 mg · kg(-1) plus intranasal saline placebo (Group CH). We recorded demographic data, times from sedative administration to start and completion of testing, quality of sedation, occurrence of predefined adverse events, discharge times, and return to baseline activity on the day of testing. Testing completion rates with a single dose of medication were higher in the IN DEX group (89% vs 66% for CH, odds ratio with 95% confidence intervals 4.04 [1.3-12.6], P = 0.018). The median [95% CI)] time to successful testing start was shorter (25 [20-29] min vs 30 [20-49] min for IN DEX and CH, respectively, log rank test P = 0.02) and the proportion of children whose parents reported a return to baseline activity on the day of testing was greater for the IN DEX than the CH group (89% vs 64%, OR [95% CI] 4.71 [1.34-16.6], P = 0.02). There were no major adverse events in either group and no significant differences in the incidence of minor events. Intranasal dexmedetomidine is an effective alternative to oral chloral hydrate sedation for ABR testing, with the advantages of a higher incidence of testing completion with a single dose, shorter time to desired sedation level, and with significantly more patients reported to return to baseline activity on the same day. © 2016 John Wiley & Sons Ltd.
Academic self-concept of ability and cortisol reactivity.
Minkley, N; Westerholt, D M; Kirchner, W H
2014-05-01
The present study aimed to clarify the relationship between a school-specific trait (academic self-concept of ability [ASCA]) and hormonal stress response by using a trait-compatible stressor (test). First, we determined 52 students' ASCA scores for biology and measured their salivary cortisol concentration before and after a biology test (experimental group, n=28) or a free writing task (control group, n=24). For participants who took the test, statistical analysis indicated a significant negative correlation between ASCA score and cortisol response. In contrast, the control group showed a decrease in cortisol concentrations between test times and no correlation between cortisol concentration and ASCA scores were found. These findings indicated an interaction between ASCA scores and hormonal stress response when an academic-related stressor is present. Furthermore, these variables might influence each other adversely: high cortisol concentrations during a test situation may lead to greater feelings of insecurity, resulting in low ASCA scores and awareness of these low scores may lead to a further increase in cortisol, creating a vicious cycle.
Barbosa, Juliana Cristina; Guida, Heraldo L; Fontes, Anne M G; Antonio, Ana M S; de Abreu, Luiz Carlos; Barnabé, Viviani; Marcomini, Renata S; Vanderlei, Luiz Carlos M; da Silva, Meire L; Valenti, Vitor E
2014-08-01
We investigated the acute effects of musical auditory stimulation on cardiac autonomic responses to a mental task in 28 healthy men (18-22 years old). In the control protocol (no music), the volunteers remained at seated rest for 10 min and the test was applied for five minutes. After the end of test the subjects remained seated for five more minutes. In the music protocol, the volunteers remained at seated rest for 10 min, then were exposed to music for 10 min; the test was then applied over five minutes, and the subjects remained seated for five more minutes after the test. In the control and music protocols the time domain and frequency domain indices of heart rate variability remained unchanged before, during and after the test. We found that musical auditory stimulation with baroque music did not influence cardiac autonomic responses to the mental task. Copyright © 2014 Elsevier Ltd. All rights reserved.
P-Them Response for Geologically Active and Non-Active Areas
NASA Astrophysics Data System (ADS)
Vetrov, A.
2011-12-01
Time Domain Electromagnetic air-borne systems are widely used in geological exploration for minerals associated with conductive rocks, underground water resources and geological underground mapping. The newly designed P-THEM system has been test-flown at the Reid Mahaffy geological test site in Northern Ontario, Canada; and then over an area near Newmarket, north of Toronto. While the flight in Reid Mahaffy was made to verify real characteristics of the system: stability and repeatability of results, the flight over the Newmarket area was made to verify correct operation of the EM system with a magnetometer and gamma-ray spectrometer. Interesting and significant response of the TDEM observations to geological, agricultural and engineering objects were observed during the test flights. These results demonstrate a possibility of TDEM method for mineral research and environmental tasks. The Reid Mahaffy Test Site is located in the Abitibi Subprovince, immediately east of the Mattagami River Fault in Ontario, Canada. The test site was created in 1999 by the Ontario Geological Survey, initially to enable various airborne geophysical systems to demonstrate their basic performance capabilities. The general geology of the site contains known overburden thickness based on almost 50 diamond drill holes, with geological logs available for these. The survey flights over Reid Mahaffy test site were performed in April 2010. The altitude and direction tests were flown on three lines over the test survey area. The response of early times represents overburden and correlates with its known thickness. The conductive body appears on later time channels and remains detectable over noise level. The electrical inversion of the results allows distinguishing a structure of several vertical conductor slices, forming the conductive body. The Newmarket area selected for tests in June 2010 is a highly developed urban zone in the Greater Toronto Area, Ontario, Canada. Geologically, the area is represented with Quadrennial sediments with underlying bedrocks of the Ordovician formation. The main area is represented with sand and gravel of Glacial lake, River and Moraine deposits. The main purpose of the test flights was to check the functional integration of the P-THEM system with a Magnetometer and Gamma-Ray Spectrometer system. The results indicated a very good agricultural response of the P-THEM system after the interpretation of the observed data. The salty soils along roads, where the salt is spread during winter time, the grounded industrial constructions and powerline towers can be observed on the mapped data (see image). The achieved results of the survey show the possibility of the TDEM airborne system for applications in characterization of environmental and engineering properties, such as detection of surface and near surface pollution, grounding of metal constructions and other, over large areas of interest.
Responsiveness of the Test of Basic Motor Skills of Children with Down Syndrome.
van den Heuvel, Marieke E; de Jong, Inge; Lauteslager, Peter E M; Volman, M J M
2009-01-01
The aim of this study was to examine the responsiveness of the Test of Basic Motor Skills for Children with Down Syndrome (BMS). Forty-one children with Down Syndrome, 3 to 36 months of age, participated in the study. Gross motor skills were assessed three times using the BMS and the Gross Motor Function Measure (GMFM) before and after a baseline period of 2 weeks (T1-T2) and after a period of 16 weeks (T2-T3). Internal and external responsiveness of the BMS was analyzed using Guyatt's Responsiveness Index (GRI) and 2 x 2 repeated measures. Change in BMS scores was compared to change in GMFM scores and parent and physiotherapist ratings of change. The responsiveness of the BMS was large (GRI = 2.55). A significant Time x Age interaction [F(1,37) = 8.87, p < .01] indicated that BMS scores increased more for children
DVA as a Diagnostic Test for Vestibulo-Ocular Reflex Function
NASA Technical Reports Server (NTRS)
Wood, Scott J.; Appelbaum, Meghan
2010-01-01
The vestibulo-ocular reflex (VOR) stabilizes vision on earth-fixed targets by eliciting eyes movements in response to changes in head position. How well the eyes perform this task can be functionally measured by the dynamic visual acuity (DVA) test. We designed a passive, horizontal DVA test to specifically study the acuity and reaction time when looking in different target locations. Visual acuity was compared among 12 subjects using a standard Landolt C wall chart, a computerized static (no rotation) acuity test and dynamic acuity test while oscillating at 0.8 Hz (+/-60 deg/s). In addition, five trials with yaw oscillation randomly presented a visual target in one of nine different locations with the size and presentation duration of the visual target varying across trials. The results showed a significant difference between the static and dynamic threshold acuities as well as a significant difference between the visual targets presented in the horizontal plane versus those in the vertical plane when comparing accuracy of vision and reaction time of the response. Visual acuity increased proportional to the size of the visual target and increased between 150 and 300 msec duration. We conclude that dynamic visual acuity varies with target location, with acuity optimized for targets in the plane of rotation. This DVA test could be used as a functional diagnostic test for visual-vestibular and neuro-cognitive impairments by assessing both accuracy and reaction time to acquire visual targets.
Using hyperspectral imagery to predict post-wildfire soil water repellency
Sarah A. Lewis; Peter R. Robichaud; Bruce E. Frazier; Joan Q. Wu; Denise Y. M. Laes
2008-01-01
A principal task of evaluating large wildfires is to assess fire's effect on the soil in order to predict the potential watershed response. Two types of soil water repellency tests, the water drop penetration time (WDPT) test and the mini-disk infiltrometer (MDI) test, were performed after the Hayman Fire in Colorado, in the summer of 2002 to assess the...
ERIC Educational Resources Information Center
Miller, Jeff; Van Nes, Fenna
2007-01-01
Two experiments tested predictions of the hemispheric coactivation model for redundancy gain (J. O. Miller, 2004). Simple reaction time was measured in divided attention tasks with visual stimuli presented to the left or right of fixation or redundantly to both sides. Experiment 1 tested the prediction that redundancy gain--the decrease in…
Testing the Data Assimilation Capability of the Profiler Virtual Module
2016-02-01
ARL-TR-7601 ● FEB 2016 US Army Research Laboratory Testing the Data Assimilation Capability of the Profiler Virtual Module by...originator. ARL-TR-7601 ● FEB 2016 US Army Research Laboratory Testing the Data Assimilation Capability of the Profiler Virtual...hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and
Vaithilingam, Vijayaganapathy; Kollarikova, Gabriella; Qi, Meirigeng; Lacik, Igor; Oberholzer, Jose; Guillemin, Gilles J; Tuch, Bernard E
2011-01-01
Pericapsular fibrotic overgrowth (PFO) may be attributed to an immune response against microcapsules themselves or to antigen shedding through microcapsule pores from encapsulated islet tissue. Modification of microcapsules aimed at reducing pore size should prevent PFO and improve graft survival. This study investigated the effect of increased gelling time (20 vs. 2 min) in barium chloride on intrinsic properties of alginate microcapsules and tested their biocompatibility in vivo. Prolonged gelling time affected neither permeability nor size of the microcapsules. However, prolonged gelling time for 20 min produced brittle microcapsules compared to 2 min during compression test. Encapsulation of human islets in both types of microcapsules affected neither islet viability nor function. The presence of PFO when transplanted into a large animal model such as baboon and its absence in small animal models such as rodents suggest that the host immune response towards alginate microcapsules is species rather than alginate specific.
Mitchell, W G; Chavez, J M; Baker, S A; Guzman, B L; Azen, S P
1990-07-01
Maturation of sustained attention was studied in a group of 52 hyperactive elementary school children and 152 controls using a microcomputer-based test formatted to resemble a video game. In nonhyperactive children, both simple and complex reaction time decreased with age, as did variability of response time. Omission errors were extremely infrequent on simple reaction time and decreased with age on the more complex tasks. Commission errors had an inconsistent relationship with age. Hyperactive children were slower, more variable, and made more errors on all segments of the game than did controls. Both motor speed and calculated mental speed were slower in hyperactive children, with greater discrepancy for responses directed to the nondominant hand, suggesting that a selective right hemisphere deficit may be present in hyperactives. A summary score (number of individual game scores above the 95th percentile) of 4 or more detected 60% of hyperactive subjects with a false positive rate of 5%. Agreement with the Matching Familiar Figures Test was 75% in the hyperactive group.
The social environment influences the behavioural responses of beef cattle to handling.
Grignard; Boissy; Boivin; Garel; Le Neindre P
2000-05-05
In cattle, a gregarious species, the social group influences individual stress responses to fear-eliciting situations. As handling can be stressful for farm animals, it can be hypothesised that social partners modify individual responses to handling. The present experiment investigated the effect of the presence or absence of social partners on behavioural reactions of beef calves in a handling test. At the age of 10 months, 38 calves from two breeds (Salers and Limousine) were individually subjected to the docility test, once while in visual contact with four familiar peers, and once in the absence of peers, following a crossover design. The docility test procedure included physical separation from peers (30 s; period 1), exposition to a stationary human (30 s; period 2), and handling by human (30 s-2.5 min, according to the success in handling; period 3). In absence of human (period 1), calves in visual contact with their peers spent more time motionless than when peers were totally absent (P<0.001). The social environment also influenced the duration of handling (period 3); the human required more time to successfully handle calves when peers were present (P<0.05). In conclusion, the presence of peers affects individual calves' reactions to the docility test.
'Omics analysis of low dose acetaminophen intake demonstrates novel response pathways in humans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jetten, Marlon J.A.; Gaj, Stan; Ruiz-Aracama, Ainhoa
2012-03-15
Acetaminophen is the primary cause of acute liver toxicity in Europe/USA, which led the FDA to reconsider recommendations concerning safe acetaminophen dosage/use. Unfortunately, the current tests for liver toxicity are no ideal predictive markers for liver injury, i.e. they only measure acetaminophen exposure after profound liver toxicity has already occurred. Furthermore, these tests do not provide mechanistic information. Here, 'omics techniques (global analysis of metabolomic/gene-expression responses) may provide additional insight. To better understand acetaminophen-induced responses at low doses, we evaluated the effects of (sub-)therapeutic acetaminophen doses on metabolite formation and global gene-expression changes (including, for the first time, full-genome humanmore » miRNA expression changes) in blood/urine samples from healthy human volunteers. Many known and several new acetaminophen-metabolites were detected, in particular in relation to hepatotoxicity-linked, oxidative metabolism of acetaminophen. Transcriptomic changes indicated immune-modulating effects (2 g dose) and oxidative stress responses (4 g dose). For the first time, effects of acetaminophen on full-genome human miRNA expression have been considered and confirmed the findings on mRNA level. 'Omics techniques outperformed clinical chemistry tests and revealed novel response pathways to acetaminophen in humans. Although no definitive conclusion about potential immunotoxic effects of acetaminophen can be drawn from this study, there are clear indications that the immune system is triggered even after intake of low doses of acetaminophen. Also, oxidative stress-related gene responses, similar to those seen after high dose acetaminophen exposure, suggest the occurrence of possible pre-toxic effects of therapeutic acetaminophen doses. Possibly, these effects are related to dose-dependent increases in levels of hepatotoxicity-related metabolites. -- Highlights: ► 'Omics techniques outperformed classic clinical chemistry tests. ► Metabolomic analyses led to the detection of five new acetaminophen metabolites. ► Low dose APAP changed immune and oxidative stress related gene expression in blood. ► APAP-induced full-genome human blood miRNA profiles were assessed for the first time.« less
NASA Astrophysics Data System (ADS)
Schipper, L. A.; Robinson, J.; O'Neill, T.; Ryburn, J.; Arcus, V. L.
2015-12-01
Developing robust models of the temperature response and sensitivity of soil respiration is critical for determining changes carbon cycling in response to climate change and at daily to annual time scales. Currently, approaches for measuring temperature dependence of soil respiration generally use long incubation times (days to weeks and months) at a limited number of incubation temperatures. Long incubation times likely allow thermal adaptation by the microbial population so that results are poorly representative of in situ soil responses. Additionally, too few incubation temperatures allows for the fit and justification of many different predictive equations, which can lead to inaccuracies when used for carbon budgeting purposes. We have developed a method to rapidly determine the response of soil respiration rate to wide range of temperatures. An aluminium block with 44 sample slots is heated at one end and cooled at the other to give a temperature gradient from 0 to 55°C at about one degree increments. Soil respiration is measured within 5 hours to minimise the possibility of thermal adaptation. We have used this method to demonstrate the similarity of temperature sensitivity of respiration for different soils from the same location across seasons. We are currently testing whether long-term (weeks to months) incubation alter temperature response and sensitivity that occurs in situ responses. This method is also well suited for determining the most appropriate models of temperature dependence and sensitivity of soil respiration (including macromolecular rate theory MMRT). With additional testing, this method is expected to be a more reliable method of measuring soil respiration rate for soil quality and modelling of soil carbon processes.
Stress and anxiety effects on positive skin test responses in young adults with allergic rhinitis.
Heffner, Kathi L; Kiecolt-Glaser, Janice K; Glaser, Ronald; Malarkey, William B; Marshall, Gailen D
2014-07-01
Anxiety and psychological stress affect allergy-related immune function. How these relations influence the evaluations of patients with allergic rhinitis is unknown. To examine whether anxiety and stress exposure affect skin prick test (SPT) responses to common allergens for which patients with atopy showed no prior positive SPT response. Patients with allergic rhinitis, evidenced by clinical history and SPT results, were admitted twice to a hospital research unit for 4 hours. In a crossover design, SPT wheals were assessed before and after the Trier Social Stress Test and then the following morning; for comparison, SPT wheals were assessed before and after a laboratory session without a stressor. Analyses focused on wheal responses for common allergens that tested negative (wheal size <3 mm larger than saline) from SPTs performed at multiple baseline assessments. After the Trier Social Stress Test, more anxious patients with atopy had a higher incidence of positive SPT reactions to antigens that previously tested negative. Anxiety was unrelated to positive SPT incidence under nonstressful conditions. Based on clinical symptom reports, newly positive SPT reactions after the stressor were apparently corrections of previously false-negative SPT reactions. The SPT wheal responses for allergens previously testing negative were enhanced after a stressor. Histamine (positive control) or saline (negative control) SPT responses were not affected. A laboratory stressor affected allergen SPT responses in more anxious patients with allergic rhinitis. In addition to clinical history, assessment of anxiety and current stress at the time of the SPT may provide valuable information about a patient's allergic status and aid in clinical decision making. Copyright © 2014 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Thermal Response Testing Takes a Step Forward
Clemenzi, Rick; Ewbank, Garen; Siglin, Judy; ...
2017-09-01
Oak Ridge National Labs has independently confirmed the accuracy of a new breakthrough Advanced Thermal Response Test (TRT) method that it claims “uses less than half of the test time, allows for a fluctuating or interruptible heat flux, performs quality validation of a GHEX installation, and yields new insights into ground thermal conductivity that warrant further research.” The new Advanced TRT approach will reduce costs and, for the first time, also determine the actual thermal conductivity of grout as it is installed. As everyone in the ground source heat pump (GSHP) industry knows, assuring the quality of the grout jobmore » of a ground heat exchanger (GHEX) is an especially vexing problem. Unless one is standing at the borehole head the entire time grouting is underway, they basically have no idea how good or bad the grouting job is or even if the loop pipe itself is installed correctly. This problem has been further brought to light with formal third party grout reports confirming that grout had been poured from the surface and that many loops were shorter than the specified depth in several projects« less
Thermal Response Testing Takes a Step Forward
DOE Office of Scientific and Technical Information (OSTI.GOV)
Clemenzi, Rick; Ewbank, Garen; Siglin, Judy
Oak Ridge National Labs has independently confirmed the accuracy of a new breakthrough Advanced Thermal Response Test (TRT) method that it claims “uses less than half of the test time, allows for a fluctuating or interruptible heat flux, performs quality validation of a GHEX installation, and yields new insights into ground thermal conductivity that warrant further research.” The new Advanced TRT approach will reduce costs and, for the first time, also determine the actual thermal conductivity of grout as it is installed. As everyone in the ground source heat pump (GSHP) industry knows, assuring the quality of the grout jobmore » of a ground heat exchanger (GHEX) is an especially vexing problem. Unless one is standing at the borehole head the entire time grouting is underway, they basically have no idea how good or bad the grouting job is or even if the loop pipe itself is installed correctly. This problem has been further brought to light with formal third party grout reports confirming that grout had been poured from the surface and that many loops were shorter than the specified depth in several projects« less
Evaluation of a Reverse Gradient Garment for prevention of bed-rest deconditioning
NASA Technical Reports Server (NTRS)
Sandler, H.; Dolkas, D.; Newsom, B.; Webb, P.; Annis, J.; Pace, N.; Grunbaum, B. W.
1983-01-01
A Reverse Gradient Garment (RGG) was used to intermittently induce venous pooling in the extremities of a magnitude similar to that seen in going from a lying to standing position during the course of a 15-d period of horizontal bed rest. Venous pooling failed to improve bed-rest-induced losses in +2.5 Gz and +3.0 Gz centrifugation tolerance or to prevent increased heart-rate responses to lower-body negative pressure (LBNP). Four subjects served as controls, four were treated. Tests during the 7-d recovery period showed fluid/electrolyte and body composition values to have returned to pre-bed-rest levels with continued depression of acceleration tolerance times (56% decreased at +2.5 Gz and 74% decreased at +3.0 Gz compared to pre-bed-rest levels) and exaggerated blood insulin response on glucose tolerance testing (blood insulin for treated group increased 95% at 1 h before bed rest and 465% during recovery). This study demonstrates that the physiologic changes after bed rest persist for significant periods of time. Acceleration tolerance time proved to be a sensitive test for the deconditioning process.
Relationship of Selected Abilities to Problem Solving Performance.
ERIC Educational Resources Information Center
Harmel, Sarah Jane
This study investigated five ability tests related to the water-jug problem. Previous analyses identified two processes used during solution: means-ends analysis and memory of visited states. Subjects were 240 undergraduate psychology students. A real-time computer system presented the problem and recorded responses. Ability tests were paper and…
5 CFR 315.608 - Noncompetitive appointment of certain former overseas employees.
Code of Federal Regulations, 2011 CFR
2011-01-01
... written test after determining that the duties and responsibilities of the applicant's overseas position were similar enough to make the written test unnecessary. (1) Tenure. A person appointed under this... individual, for example, ill health or personal interest in relocating. (d) Time limit on eligibility. An...
5 CFR 315.608 - Noncompetitive appointment of certain former overseas employees.
Code of Federal Regulations, 2013 CFR
2013-01-01
... written test after determining that the duties and responsibilities of the applicant's overseas position were similar enough to make the written test unnecessary. (1) Tenure. A person appointed under this... individual, for example, ill health or personal interest in relocating. (d) Time limit on eligibility. An...
Efficient and optimized identification of generalized Maxwell viscoelastic relaxation spectra.
Babaei, Behzad; Davarian, Ali; Pryse, Kenneth M; Elson, Elliot L; Genin, Guy M
2015-03-01
Viscoelastic relaxation spectra are essential for predicting and interpreting the mechanical responses of materials and structures. For biological tissues, these spectra must usually be estimated from viscoelastic relaxation tests. Interpreting viscoelastic relaxation tests is challenging because the inverse problem is expensive computationally. We present here an efficient algorithm that enables rapid identification of viscoelastic relaxation spectra. The algorithm was tested against trial data to characterize its robustness and identify its limitations and strengths. The algorithm was then applied to identify the viscoelastic response of reconstituted collagen, revealing an extensive distribution of viscoelastic time constants. Copyright © 2015 Elsevier Ltd. All rights reserved.
Normal Pressure Hydrocephalus: Diagnosis and Treatment
Shprecher, David; Schwalb, Jason; Kurlan, Roger
2009-01-01
Normal pressure hydrocephalus (NPH) is a syndrome of gait dysfunction and enlarged cerebral ventricles in the absence of another cause. It is frequently accompanied by frontal and subcortical cognitive deficits and bladder detrusor overactivity. NPH is rare relative to other potential causes of these symptoms in the elderly, but timely diagnosis can lead to reversal of symptoms through ventricular shunting. There are many tests used to predict possible response to surgery, such as MRI of the brain, formalized neuropsychological and gait testing, large-volume lumbar puncture, and prolonged lumbar drainage, but no one test has been validated to rule out potential response to surgery. PMID:18713572
Vu, Wendy T; Chang, Peter L; Moriuchi, Ken S; Friesen, Maren L
2015-04-01
Transgenerational plasticity provides phenotypic variation that contributes to adaptation. For plants, the timing of seed germination is critical for offspring survival in stressful environments, as germination timing can alter the environmental conditions a seedling experiences. Stored seed transcripts are important determinants of seed germination, but have not previously been linked with transgenerational plasticity of germination behavior. In this study we used RNAseq and growth chamber experiments of the model legume M. trucantula to test whether parental exposure to salinity stress influences the expression of stored seed transcripts and early offspring traits and test for genetic variation. We detected genotype-dependent parental environmental effects (transgenerational plasticity) on the expression levels of stored seed transcripts, seed size, and germination behavior of four M. truncatula genotypes. More than 50% of the transcripts detected in the mature, ungerminated seed transcriptome were annotated as regulating seed germination, some of which are involved in abiotic stress response and post-embryonic development. Some genotypes showed increased seed size in response to parental exposure to salinity stress, but no parental environmental influence on germination timing. In contrast, other genotypes showed no seed size differences across contrasting parental conditions but displayed transgenerational plasticity for germimation timing, with significantly delayed germination in saline conditions when parental plants were exposed to salinity. In genotypes that show significant transgenerational plastic germination response, we found significant coexpression networks derived from salt responsive transcripts involved in post-transcriptional regulation of the germination pathway. Consistent with the delayed germination response to saline conditions in these genotypes, we found genes associated with dormancy and up-regulation of abscisic acid (ABA). Our results demonstrate genetic variation in transgenerational plasticity within M. truncatula and show that parental exposure to salinity stress influences the expression of stored seed transcripts, seed weight, and germination behavior. Furthermore, we show that the parental environment influences gene expression to modulate biological pathways that are likely responsible for offspring germination responses to salinity stress.
Clock Controller For Ac Self-Timing Analysis Of Logic System
Lo, Tinchee; Flanagan, John D.
2004-05-18
A clock controller and clock generating method are provided for AC self-test timing analysis of a logic system. The controller includes latch circuitry which receives a DC input signal at a data input, and a pair of continuous out-of-phase clock signals at capture and launch clock inputs thereof. The latch circuitry outputs two overlapping pulses responsive to the DC input signal going high. The two overlapping pulses are provided to waveform shaper circuitry which produces therefrom two non-overlapping pulses at clock speed of the logic system to be tested. The two non-overlapping pulses are a single pair of clock pulses which facilitate AC self-test timing analysis of the logic system.
LLNL Small-Scale Friction sensitivity (BAM) Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpson, L.R.; Foltz, M.F.
1996-06-01
Small-scale safety testing of explosives, propellants and other energetic materials, is done to determine their sensitivity to various stimuli including friction, static spark, and impact. Testing is done to discover potential handling problems for either newly synthesized materials of unknown behavior, or materials that have been stored for long periods of time. This report describes the existing {open_quotes}BAM{close_quotes} Small-Scale Friction Test, and the methods used to determine the friction sensitivity pertinent to handling energetic materials. The accumulated data for the materials tested is not listed here - that information is in a database. Included is, however, a short list ofmore » (1) materials that had an unusual response, and (2), a few {open_quotes}standard{close_quotes} materials representing the range of typical responses usually seen.« less
Xu, Xiaojuan; Weber, Daniel; Burge, Rebekah; VanAmberg, Kelsey
2016-01-01
The zebrafish has become a useful animal model for studying the effects of environmental contaminants on neurobehavioral development due to its ease of breeding, high number of eggs per female, short generation times, and a well-established avoidance conditioning paradigm. Using avoidance conditioning as the behavioral paradigm, the present study investigated the effects of embryonic exposure to lead (Pb) on learning in adult zebrafish and the third (F3) generation of those fish. In Experiment 1, adult zebrafish that were developmentally exposed to 0.0, 0.1, 1.0 or 10.0μM Pb (2-24h post fertilization) as embryos were trained and tested for avoidance responses. The results showed that adult zebrafish hatched from embryos exposed to 0.0 or 0.1μM Pb learned avoidance responses during training and displayed significantly increased avoidance responses during testing, while those hatched from embryos exposed to 1.0 or 10.0μM Pb displayed no significant increases in avoidance responses from training to testing. In Experiment 2, the F3 generation of zebrafish that were developmentally exposed to an identical exposure regimen as in Experiment 1 were trained and tested for avoidance responses. The results showed that the F3 generation of zebrafish developmentally exposed as embryos to 0.0 or 0.1μM Pb learned avoidance responses during training and displayed significantly increased avoidance responses during testing, while the F3 generation of zebrafish developmentally exposed as embryos to 1.0 or 10.0μM Pb displayed no significant changes in avoidance responses from training to testing. Thus, developmental Pb exposure produced learning impairments that persisted for at least three generations, demonstrating trans-generational effects of embryonic exposure to Pb. Copyright © 2015. Published by Elsevier B.V.
Tsuru, Jusen; Tanaka, Yoshihiro; Ishitobi, Yoshinobu; Maruyama, Yoshihiro; Inoue, Ayako; Kawano, Aimi; Ikeda, Rie; Ando, Tomoko; Oshita, Harumi; Aizawa, Saeko; Masuda, Koji; Higuma, Haruka; Kanehisa, Masayuki; Ninomiya, Taiga; Akiyoshi, Jotaro
2014-01-01
Decreased expression of brain-derived neurotrophic factor (BDNF) is implicated in enhanced stress responses. The BDNF Val66Met polymorphism is associated with psychological changes; for example, carriers of the Met allele exhibit increased harm avoidance as well as a higher prevalence of depression and anxiety disorder. To analyze the effects of BDNF Val66Met on stress responses, we tested 226 university students (88 women and 138 men) using a social stress procedure (Trier Social Stress Test [TSST]) and an electrical stimulation stress test. Stress indices were derived from repeated measurements of salivary α-amylase, salivary cortisol, heart rate, and psychological testing during the stress tests. All subjects were genotyped for the Val66Met polymorphism (G196A). A significant three-way interaction (time [3 levels] × BDNF [Val/Val, Val/Met, Met/Met]; P<0.05) was demonstrated that revealed different salivary cortisol responses in the TSST but not in electrical stimulation. Met/Met women had stronger cortisol responses than Val/Met and Val/Val individuals in the TSST. Met/Met men exhibited stronger salivary cortisol responses than Val/Met and Val/Val individuals in the TSST. These results indicate that a common, functionally significant polymorphism in BDNF had different effects on hypothalamic-pituitary-adrenocortical axis reactivity but not on sympathetic adrenomedullary reactivity in TSST and electrical stimulation tests.
Design, fabrication, and measurement of two silicon-based ultraviolet and blue-extended photodiodes
NASA Astrophysics Data System (ADS)
Chen, Changping; Wang, Han; Jiang, Zhenyu; Jin, Xiangliang; Luo, Jun
2014-12-01
Two silicon-based ultraviolet (UV) and blue-extended photodiodes are presented, which were fabricated for light detection in the ultraviolet/blue spectral range. Stripe-shaped and octagon-ring-shaped structures were designed to verify parameters of the UV-responsivity, UV-selectivity, breakdown voltage, and response time. The ultra-shallow lateral pn junction had been successfully realized in a standard 0.5-μm complementary metal oxide semiconductor (CMOS) process to enlarge the pn junction area, enhance the absorption of UV light, and improve the responsivity and quantum efficiency. The test results illustrated that the stripe-shaped structure has the lower breakdown voltage, higher UV-responsicity, and higher UV-selectivity. But the octagon-ring-shaped structure has the lower dark current. The response time of both structures was almost the same.
Novel MCP-Based Electron Source Studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haughey, M.; Shiltsev V., Shiltsev V.; Stancari, G.
Microchannel plates (MCPs) were recently proposed as novel type of cathodes for electron guns [1], suitable for applications in design of electron lenses. We report results of the first systematic study of microchannel plate based photomultiplier time response and maximum cur-rent density tests using different sources of light pulses. The Burle 85011-501 MCP-PMT is found to have good time response properties being capable of producing na-nosecond long pulses with modest maximum current density and performance strongly dependent on magnetic field strength.
Effect of Ovarian Hormone Therapy on Cognition in the Aged Female Rhesus Macaque.
Kohama, Steven G; Renner, Lauren; Landauer, Noelle; Weiss, Alison R; Urbanski, Henryk F; Park, Byung; Voytko, Mary Lou; Neuringer, Martha
2016-10-05
Studies of the effect of hormone therapy on cognitive function in menopausal women have been equivocal, in part due to differences in the type and timing of hormone treatment. Here we cognitively tested aged female rhesus macaques on (1) the delayed response task of spatial working memory, (2) a visuospatial attention task that measured spatially and temporally cued reaction times, and (3) a simple reaction time task as a control for motor speed. After task acquisition, animals were ovariectomized (OVX). Their performance was compared with intact controls for 2 months, at which time no group differences were found. The OVX animals were then assigned to treatment with either a subcutaneous sham implant (OVX), 17-β estradiol (E) implant (OVX+E) or E implant plus cyclic oral progesterone (OVX+EP). All groups were then tested repeatedly over 12 months. The OVX+E animals performed significantly better on the delayed response task than all of the other groups for much of the 12 month testing period. The OVX+EP animals also showed improved performance in the delayed response task, but only at 30 s delays and with performance levels below that of OVX+E animals. The OVX+E animals also performed significantly better in the visuospatial attention task, particularly in the most challenging invalid cue condition; this difference also was maintained across the 12 month testing period. Simple reaction time was not affected by hormonal manipulation. These data demonstrate that chronic, continuous administration of E can exert multiple beneficial cognitive effects in aged, OVX rhesus macaque females. Hormone therapy after menopause is controversial. We tested the effects of hormone replacement in aged rhesus macaques, soon after surgically-induced menopause [ovariectomy (OVX)], on tests of memory and attention. Untreated ovarian-intact and OVX animals were compared with OVX animals receiving estradiol (E) alone or E with progesterone (P). E was administered in a continuous fashion via subcutaneous implant, whereas P was administered orally in a cyclic fashion. On both tests, E-treated animals performed better than the other 3 experimental groups across 1 year of treatment. Thus, in this monkey model, chronic E administered soon after the loss of ovarian hormones had long-term benefits for cognitive function. Copyright © 2016 the authors 0270-6474/16/3610416-09$15.00/0.
Most toxicological testing focuses on defining concentration/dose-response relationships, with little consideration given to temporal aspects of the expression of chemical effects. Yet, both variablesdose and timeare critical to robust evaluations of potential risks. Over the p...
Utilizing Response Time Distributions for Item Selection in CAT
ERIC Educational Resources Information Center
Fan, Zhewen; Wang, Chun; Chang, Hua-Hua; Douglas, Jeffrey
2012-01-01
Traditional methods for item selection in computerized adaptive testing only focus on item information without taking into consideration the time required to answer an item. As a result, some examinees may receive a set of items that take a very long time to finish, and information is not accrued as efficiently as possible. The authors propose two…