Science.gov

Sample records for resulting radiation doses

  1. Estimation of the committed radiation dose resulting from gamma radionuclides ingested with food.

    PubMed

    Godyń, Piotr; Dołhańczuk-Śródka, Agnieszka; Ziembik, Zbigniew; Moliszewska, Ewa

    The objective of the study was to estimate the value of the radiation dose absorbed in consequence of consumption of popular food products for individual age groups. Potatoes, corn and sugar beet were selected for the study. Edible parts of these plants were collected in experimental fields of the KWS Lochów Polska Sp. z o.o. seeding company in Kondratowice (Poland). On the basis of the obtained study results, it can be stated that in consequence of consumption of the selected food products, people may receive increased doses from both natural and artificial radioactive isotopes. The doses calculated for several age groups do not show any health hazards in consequence of consumption of the tested food. One of the determined radionuclides was (137)Cs; however, its presence in the absorbed dose is lower than the doses from natural radioactive isotopes, in particular (40)K.

  2. Radiation doses resulting from variations in spent fuel/waste management systems without Monitored Retrievable Storage

    SciTech Connect

    Schneider, K.J.; Pelto, P.J.; Lavender, J.C.; Daling, P.M.; Fecht, B.A.

    1987-02-01

    This paper presents results of analyses of radiological dose impacts on the public and the workers of nine potential transportation-related changes in the operation of a hypothetical high-level waste management system that does not include a Monitored Retrievable Storage (MRS) facility. The analyses were performed for the US Department of Energy (DOE) to determine if some of the benefits proposed for the improved performance waste management system (one with an MRS facility) could also benefit the authorized system (one without an MRS facility). The study showed that most of the alternatives evaluated would reduce the radiation doses to the public and the workers. Of the alternatives evaluated, the primary means for reducing these radiation doses is to increase the capacity of the transportation casks.

  3. Variation in CT pediatric head examination radiation dose: results from a national survey.

    PubMed

    Kanal, Kalpana M; Graves, Janessa M; Vavilala, Monica S; Applegate, Kimberly E; Jarvik, Jeffrey G; Rivara, Frederick P

    2015-03-01

    OBJECTIVE. The purpose of this article is to examine the variation in radiation dose, CT dose index volume (CTDIvol), and dose-length product (DLP) for pediatric head CT examinations as a function of hospital characteristics across the United States. MATERIALS AND METHODS. A survey inquiring about hospital information, CT scanners, pediatric head examination protocol, CTDIvol, and DLP was mailed to a representative sample of U.S. hospitals. Follow-up mailings were sent to nonrespondents. Descriptive characteristics of respondents and nonrespondents were compared using design-based Pearson chi-square tests. Dose estimates were compared across hospital characteristics using Bonferroni-adjusted Wald test. Hospital-level factors associated with dose estimates were evaluated using multiple linear regressions and modified Poisson regression models. RESULTS. Surveys were sent out to 751 hospitals; 292 responded to the survey, of which 253 were eligible (35.5% response rate, calculated as number of hospitals who completed surveys [n = 253] divided by sum of number who were eligible and initially consented [n = 712] plus estimated number who were eligible among those who refused [n = 1]). Most respondents reported using MDCT scanners (99.2%) and having a dedicated pediatric head CT protocol (93%). Estimated mean reported CTDIvol values were 27.3 mGy (95% CI, 24.4-30.1 mGy), and DLP values were 390.9 mGy × cm (95% CI, 346.6-435.1 mGy × cm). These values did not vary significantly by region, trauma level, teaching status, CT accreditation, number of CT scanners, or report of a dedicated pediatric CT protocol. However, estimated CTDIvol reported by children's hospitals was 19% lower than that reported by general hospitals (p < 0.01). CONCLUSION. Most hospitals (82%) report doses that meet American College of Radiology accreditation levels. However, [corrected] the mean CTDI(vol) at children's hospitals was approximately 7 mGy (21%, adjusted for covariates), lower than that

  4. Higher Chest Wall Dose Results in Improved Locoregional Outcome in Patients Receiving Postmastectomy Radiation

    SciTech Connect

    Panoff, Joseph E.; Takita, Cristiane; Hurley, Judith; Reis, Isildinha M.; Zhao, Wei; Rodgers, Steven E.; Gunaseelan, Vijayalakshmi; Wright, Jean L.

    2012-03-01

    Purpose: Randomized trials demonstrating decreased locoregional recurrence (LRR) and improved overall survival (OS) in women receiving postmastectomy radiation therapy (PMRT) used up to 50 Gy to the chest wall (CW), but in practice, many centers boost the CW dose to {>=}60 Gy, despite lack of data supporting this approach. We evaluated the relationship between CW dose and clinical outcome. Methods and Materials: We retrospectively reviewed medical records of 582 consecutively treated patients who received PMRT between January 1999 and December 2009. We collected data on patient, disease, treatment characteristics, and outcomes of LRR, progression-free survival (PFS) and OS. Results: Median follow-up from the date of diagnosis was 44.7 months. The cumulative 5-year incidence of LRR as first site of failure was 6.2%. CW dose for 7% (43 patients) was {<=}50.4 Gy (range, 41.4-50.4 Gy) and 93% received >50.4 Gy (range, 52.4-74.4 Gy). A CW dose of >50.4 Gy vs. {<=}50.4 Gy was associated with lower incidence of LRR, a 60-month rate of 5.7% (95% confidence interval [CI], 3.7-8.2) vs. 12.7% (95% CI, 4.5-25.3; p = 0.054). Multivariate hazard ratio (HR) for LRR controlling for race, receptor status, and stage was 2.62 (95% CI, 1.02-7.13; p = 0.042). All LRR in the low-dose group occurred in patients receiving 50 to 50.4 Gy. Lower CW dose was associated with worse PFS (multivariate HR, 2.73; 95% CI, 1.64-4.56; p < 0.001) and OS (multivariate HR, 3.88; 95% CI, 2.16-6.99; p < 0.001). Conclusions: The addition of a CW boost above 50.4 Gy resulted in improved locoregional control and survival in this cohort patients treated with PMRT for stage II-III breast cancer. The addition of a CW boost to standard-dose PMRT is likely to benefit selected high-risk patients. The optimal technique, target volume, and patient selection criteria are unknown. The use of a CW boost should be studied prospectively, as has been done in the setting of breast conservation.

  5. Offsite radiation doses from Hanford Operations for the years 1983 through 1987: A comparison of results calculated by two methods

    SciTech Connect

    Soldat, J.K.

    1989-10-01

    This report compares the results of the calculation of potential radiation doses to the public by two different environmental dosimetric systems for the years 1983 through 1987. Both systems project the environmental movement of radionuclides released with effluents from Hanford operations; their concentrations in air, water, and foods; the intake of radionuclides by ingestion and inhalation; and, finally, the potential radiation doses from radionuclides deposited in the body and from external sources. The first system, in use for the past decade at Hanford, calculates radiation doses in terms of 50-year cumulative dose equivalents to body organs and to the whole body, based on the methodology defined in ICRP Publication 2. This system uses a suite of three computer codes: PABLM, DACRIN, and KRONIC. In the new system, 50-year committed doses are calculated in accordance with the recommendations of the ICRP Publications 26 and 30, which were adopted by the US Department of Energy (DOE) in 1985. This new system calculates dose equivalent (DE) to individual organs and effective dose equivalent (EDE). The EDE is a risk-weighted DE that is designed to be an indicator of the potential health effects arising from the radiation dose. 16 refs., 1 fig., 38 tabs.

  6. SU-E-J-204: Radiation Dose to Patients Resulting From Image Guidance Procedures and AAPM TG-180 Update

    SciTech Connect

    Ding, G; Alaei, P

    2014-06-01

    Purpose: Image-guided radiation therapy (IGRT) is the new paradigm for patient positioning and target localization in radiotherapy. Daily imaging procedures add additional dose to the patient's treatment volume and normal tissues and may expose the organs at risk to unaccounted doses. This presentation is to update the progress of AAPM TG-180 which aims to provide strategies to quantify and account the dose from both MV and kV imaging in patient treatment planning. Methods: Our current knowledge on image guidance dose is presented. A summary of doses from image guidance procedures delivered to patients in relationship with therapeutic doses is given. Different techniques in reducing the image guidance dose are summarized. Typical organ doses resulting from different image acquisition procedures used in IGRT are tabulated. Results: Many techniques to reduce the imaging doses are available in clinical applications. There are large variations between dose to bone and dose to soft tissues for x-rays at kilovoltage energy range. Methods for clinical implementation of accounting for the imaging dose from an imaging procedure are available. Beam data from imaging systems can be generated by combining Monte Carlo simulations and experimental measurements for commissioning imaging beams in the treatment planning. Conclusion: The current treatment planning systems are not yet equipped to perform patient specific dose calculations resulting from kV imaging procedures. The imaging dose from current kV image devices has been significantly reduced and is generally much less than that resulting from MV. Because the magnitude of kV imaging dose is significantly low and the variation between patients is modest, it is feasible to estimate dose based on imaging producers or protocols using tabulated values which provides an alternative to accomplish the task of accounting and reporting imaging doses.

  7. Measurements of natural radioactivity and the resulting radiation doses from commercial granites.

    PubMed

    Aydarous, A Sh; Zeghib, Sadek; Al-Dughmah, Mohammed

    2010-12-01

    Saudi Arabia is becoming a relatively large market for local and foreign marble and granite use in dwellings. Due to increasing concern about environmental radiological protection, different types of locally widely used granite tiles were collected from different suppliers in the Jeddah province, Saudi Arabia. The analysis for these granite tiles for gamma radiation was conducted by means of a high-resolution HPGe gamma-spectroscopy system. The activity concentrations of (232)Th, (226)Ra and 40K in the selected granite samples ranged from 4.9 to 144, 9.7 to 133 and 168 to 1806 Bq kg(-1), respectively. The data were compared with other granite types and building materials used all over the world. The absorbed dose rates, effective dose rates, radium equivalent activities as well as the radiation hazard indices were estimated. The radium equivalent activities (Ra(eq)) are lower than the limit of 370 Bq kg(-1) set by the Organisation for Economic Cooperation and Development (Exposure to radiation from the natural radioactivity in building materials. Report by a Group of Experts of the OECD, Nuclear Energy Agency, OECD, Paris, 1979) except in three samples.

  8. Radiation Dose Survey for Common Computed Tomography Exams: 2013 British Columbia Results.

    PubMed

    Thakur, Yogesh; Bjarnason, Thorarin A; Baxter, Patricia; Griffith, Mitch; Eaton, Kirk

    2016-02-01

    In 2013 Health Canada conducted a national survey of computed tomography (CT) radiation usage. We analysed contributions from all 7 public health authorities in the province of British Columbia, which covered scanner age, number of slices, and common adult protocols (≥ 19 years: 70 ± 20 kg, head, chest, abdomen/pelvis, and trunk). Patient doses were recorded for common protocols. Diagnostic reference levels (DRLs) was calculated using scanner data with >10 patient doses recorded for each protocol. Data was analysed based on image reconstruction (filtered backprojection vs iterative reconstruction [IR] vs IR available but not in use). Provincial response was 92%, with 59 of 64 CT data used for analysis. The average scanner age was 5.5 years old, with 39% of scanners installed between 2008-2013; 78.5% of scanners were multislice (>64 slices), and 44% of scanners had IR available. Overall British Columbia DRLs were: head = 1305, chest = 529, abdomen/pelvis = 819, and trunk = 1225. DRLs were consistent with Health Canada recommendations and other Canadian published values, but above international standards. For sites with IR available, less than 50% used this technology routinely for head, chest and trunk exams. Overall, use of IR reduced radiation usage between 11%-32% compared to filtered backprojection, while sites using IR vs IR available used 30%/43% less radiation for head/chest exams (P < .05). No significant difference was observed for abdomen/pelvis exams (P = .385). With the fast pace of CT technical advancement, DRLs should reflect the technology used, instead of just globally applied to anatomical regions. Federal guidelines should be updated at a higher frequency to reflect new technology. In addition, new technologies must be utilised to optimize image quality vs radiation usage. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  9. Acute Exposure to High Dose γ-Radiation Results in Transient Activation of Bone Lining Cells

    PubMed Central

    Turner, Russell T.; Iwaniec, Urszula T.; Wong, Carmen P.; Lindenmaier, Laurence B.; Wagner, Lindsay A.; Branscum, Adam J.; Menn, Scott A.; Taylor, James; Zhang, Ye; Wu, Honglu; Sibonga, Jean D.

    2014-01-01

    The present studies investigated the cellular mechanisms for the detrimental effects of high dose whole body γ-irradiation on bone. In addition, radioadaptation and bone marrow transplantation were assessed as interventions to mitigate the skeletal complications of irradiation. Increased trabecular thickness and separation and reduced fractional cancellous bone volume, connectivity density, and trabecular number were detected in proximal tibia and lumbar vertebra 14 days following γ-irradiation with 6 Gy. To establish the cellular mechanism for the architectural changes, vertebrae were analyzed by histomorphometry 1, 3, and 14 days following irradiation. Marrow cell density decreased within 1 day (67% reduction, p<0.0001), reached a minimum value after 3 days (86% reduction, p<0.0001), and partially rebounded by 14 days (30% reduction, p=0.0025) following irradiation. In contrast, osteoblast-lined bone perimeter was increased by 290% (1 day, p=0.04), 1230% (3 days, p<0.0001), and 530% (14 days, p=0.003), respectively. There was a strong association between radiation-induced marrow cell death and activation of bone lining cells to express the osteoblast phenotype (Pearson correlation −0.85, p<0.0001). An increase (p=0.004) in osteoclast-lined bone perimeter was also detected with irradiation. A priming dose of γ-radiation (0.5 mGy), previously shown to reduce mortality, had minimal effect on the cellular responses to radiation and did not prevent detrimental changes in bone architecture. Bone marrow transplantation normalized marrow cell density, bone turnover, and most indices of bone architecture following irradiation. In summary, radiation-induced death of marrow cells is associated with 1) a transient increase in bone formation due, at least in part, to activation of bone lining cells, and 2) an increase in bone resorption due to increased osteoclast perimeter. Bone marrow transplantation is effective in mitigating the detrimental effects of acute exposure

  10. Radiation dose in dental radiology.

    PubMed

    Cohnen, M; Kemper, J; Möbes, O; Pawelzik, J; Mödder, U

    2002-03-01

    The aim of this study was to compare radiation exposure in panoramic radiography (PR), dental CT, and digital volume tomography (DVT). An anthropomorphic Alderson-Rando phantom and two anatomical head phantoms with thermoluminescent dosimeters fixed at appropriate locations were exposed as in a dental examination. In PR and DVT, standard parameters were used while variables in CT included mA, pitch, and rotation time. Image noise was assessed in dental CT and DVT. Radiation doses to the skin and internal organs within the primary beam and resulting from scatter radiation were measured and expressed as maximum doses in mGy. For PR, DVT, and CT, these maximum doses were 0.65, 4.2, and 23 mGy. In dose-reduced CT protocols, radiation doses ranged from 10.9 to 6.1 mGy. Effective doses calculated on this basis showed values below 0.1 mSv for PR, DVT, and dose-reduced CT. Image noise was similar in DVT and low-dose CT. As radiation exposure and image noise of DVT is similar to low-dose CT, this imaging technique cannot be recommended as a general alternative to replace PR in dental radiology.

  11. Preliminary results of radiation dose escalation for locally advanced nasopharyngeal carcinoma

    SciTech Connect

    Kwong, Dora L.W. . E-mail: dlwkwong@hkucc.hku.hk; Sham, Jonathan S.T.; Leung, Lucullus H.T.; Cheng, Ashley C.K.; Ng, W.M.; Kwong, Philip W.K.; Lui, W.M.; Yau, C.C.; Wu, P.M.; Wei, William; Au, Gordon

    2006-02-01

    Purpose: To study the safety and efficacy of dose escalation in tumor for locally advanced nasopharyngeal carcinoma (NPC). Methods and Materials: From September 2000 to June 2004, 50 patients with T3-T4 NPC were treated with intensity-modulated radiotherapy (IMRT). Fourteen patients had Stage III and 36 patients had Stage IVA-IVB disease. The prescribed dose was 76 Gy to gross tumor volume (GTV), 70 Gy to planning target volume (PTV), and 72 Gy to enlarged neck nodes (GTVn). All doses were given in 35 fractions over 7 weeks. Thirty-four patients also had concurrent cisplatin and induction or adjuvant PF (cisplatin and 5-fluorouracil). Results: The average mean dose achieved in GTV, GTVn, and PTV were 79.5 Gy, 75.3 Gy, and 74.6 Gy, respectively. The median follow-up was 25 months, with 4 recurrences: 2 locoregional and 2 distant failures. All patients with recurrence had IMRT alone without chemotherapy. The 2-year locoregional control rate, distant metastases-free and disease-free survivals were 95.7%, 94.2%, and 93.1%, respectively. One treatment-related death caused by adjuvant chemotherapy occurred. The 2-year overall survival was 92.1%. Conclusions: Dose escalation to 76 Gy in tumor is feasible with T3-T4 NPC and can be combined with chemotherapy. Initial results showed good local control and survival.

  12. Radiation dose estimates for radiopharmaceuticals

    SciTech Connect

    Stabin, M.G.; Stubbs, J.B.; Toohey, R.E.

    1996-04-01

    Tables of radiation dose estimates based on the Cristy-Eckerman adult male phantom are provided for a number of radiopharmaceuticals commonly used in nuclear medicine. Radiation dose estimates are listed for all major source organs, and several other organs of interest. The dose estimates were calculated using the MIRD Technique as implemented in the MIRDOSE3 computer code, developed by the Oak Ridge Institute for Science and Education, Radiation Internal Dose Information Center. In this code, residence times for source organs are used with decay data from the MIRD Radionuclide Data and Decay Schemes to produce estimates of radiation dose to organs of standardized phantoms representing individuals of different ages. The adult male phantom of the Cristy-Eckerman phantom series is different from the MIRD 5, or Reference Man phantom in several aspects, the most important of which is the difference in the masses and absorbed fractions for the active (red) marrow. The absorbed fractions for flow energy photons striking the marrow are also different. Other minor differences exist, but are not likely to significantly affect dose estimates calculated with the two phantoms. Assumptions which support each of the dose estimates appears at the bottom of the table of estimates for a given radiopharmaceutical. In most cases, the model kinetics or organ residence times are explicitly given. The results presented here can easily be extended to include other radiopharmaceuticals or phantoms.

  13. Atmospheric radiation flight dose rates

    NASA Astrophysics Data System (ADS)

    Tobiska, W. K.

    2015-12-01

    Space weather's effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun's photons, particles, and fields. Of the domains that are affected by space weather, the coupling between the solar and galactic high-energy particles, the magnetosphere, and atmospheric regions can significantly affect humans and our technology as a result of radiation exposure. Space Environment Technologies (SET) has been conducting space weather observations of the atmospheric radiation environment at aviation altitudes that will eventually be transitioned into air traffic management operations. The Automated Radiation Measurements for Aerospace Safety (ARMAS) system and Upper-atmospheric Space and Earth Weather eXperiment (USEWX) both are providing dose rate measurements. Both activities are under the ARMAS goal of providing the "weather" of the radiation environment to improve aircraft crew and passenger safety. Over 5-dozen ARMAS and USEWX flights have successfully demonstrated the operation of a micro dosimeter on commercial aviation altitude aircraft that captures the real-time radiation environment resulting from Galactic Cosmic Rays and Solar Energetic Particles. The real-time radiation exposure is computed as an effective dose rate (body-averaged over the radiative-sensitive organs and tissues in units of microsieverts per hour); total ionizing dose is captured on the aircraft, downlinked in real-time, processed on the ground into effective dose rates, compared with NASA's Langley Research Center (LaRC) most recent Nowcast of Atmospheric Ionizing Radiation System (NAIRAS) global radiation climatology model runs, and then made available to end users via the web and smart phone apps. Flight altitudes now exceed 60,000 ft. and extend above commercial aviation altitudes into the stratosphere. In this presentation we describe recent ARMAS and USEWX results.

  14. Multileaf Collimator Tracking Improves Dose Delivery for Prostate Cancer Radiation Therapy: Results of the First Clinical Trial

    SciTech Connect

    Colvill, Emma; Booth, Jeremy T.; O'Brien, Ricky T.; Eade, Thomas N.; Kneebone, Andrew B.; Poulsen, Per R.; Keall, Paul J.

    2015-08-01

    Purpose: To test the hypothesis that multileaf collimator (MLC) tracking improves the consistency between the planned and delivered dose compared with the dose without MLC tracking, in the setting of a prostate cancer volumetric modulated arc therapy trial. Methods and Materials: Multileaf collimator tracking was implemented for 15 patients in a prostate cancer radiation therapy trial; in total, 513 treatment fractions were delivered. During each treatment fraction, the prostate trajectory and treatment MLC positions were collected. These data were used as input for dose reconstruction (multiple isocenter shift method) to calculate the treated dose (with MLC tracking) and the dose that would have been delivered had MLC tracking not been applied (without MLC tracking). The percentage difference from planned for target and normal tissue dose-volume points were calculated. The hypothesis was tested for each dose-volume value via analysis of variance using the F test. Results: Of the 513 fractions delivered, 475 (93%) were suitable for analysis. The mean difference and standard deviation between the planned and treated MLC tracking doses and the planned and without-MLC tracking doses for all 475 fractions were, respectively, PTV D{sub 99%} −0.8% ± 1.1% versus −2.1% ± 2.7%; CTV D{sub 99%} −0.6% ± 0.8% versus −0.6% ± 1.1%; rectum V{sub 65%} 1.6% ± 7.9% versus −1.2% ± 18%; and bladder V{sub 65%} 0.5% ± 4.4% versus −0.0% ± 9.2% (P<.001 for all dose-volume results). Conclusion: This study shows that MLC tracking improves the consistency between the planned and delivered doses compared with the modeled doses without MLC tracking. The implications of this finding are potentially improved patient outcomes, as well as more reliable dose-volume data for radiobiological parameter determination.

  15. Prenatal radiation exposure: dose calculation.

    PubMed

    Scharwächter, C; Röser, A; Schwartz, C A; Haage, P

    2015-05-01

    The unborn child requires special protection. In this context, the indication for an X-ray examination is to be checked critically. If thereupon radiation of the lower abdomen including the uterus cannot be avoided, the examination should be postponed until the end of pregnancy or alternative examination techniques should be considered. Under certain circumstances, either accidental or in unavoidable cases after a thorough risk assessment, radiation exposure of the unborn may take place. In some of these cases an expert radiation hygiene consultation may be required. This consultation should comprise the expected risks for the unborn while not perturbing the mother or the involved medical staff. For the risk assessment in case of an in-utero x-ray exposition deterministic damages with a defined threshold dose are distinguished from stochastic damages without a definable threshold dose. The occurrence of deterministic damages depends on the dose and the developmental stage of the unborn at the time of radiation. To calculate the risks of an in-utero radiation exposure a three-stage concept is commonly applied. Depending on the amount of radiation, the radiation dose is either estimated, roughly calculated using standard tables or, in critical cases, accurately calculated based on the individual event. The complexity of the calculation thereby increases from stage to stage. An estimation based on stage one is easily feasible whereas calculations based on stages two and especially three are more complex and often necessitate execution by specialists. This article demonstrates in detail the risks for the unborn child pertaining to its developmental phase and explains the three-stage concept as an evaluation scheme. It should be noted, that all risk estimations are subject to considerable uncertainties. • Radiation exposure of the unborn child can result in both deterministic as well as stochastic damage und hitherto should be avoided or reduced to a minimum

  16. 60Co contamination in recycled steel resulting in elevated civilian radiation doses: causes and challenges.

    PubMed

    Chang, W P; Chan, C C; Wang, J D

    1997-09-01

    Since late 1992, more than 100 building complexes containing public and private schools and nearly 1,000 apartments have been identified in Taiwan with elevated levels of gamma-radiation from construction steel contaminated with 60Co. Due to improper handling of 60Co contaminated scrap steel in late 1982 and 1983, contaminated construction materials have been widely distributed throughout the country. These contaminated construction materials have generated elevated radiation exposures to members of the public in Taiwan. As of early 1996, more than 4,000 people, including young students, have been identified as receiving more than 1 mSv y(-1) above the local background for up to 12 y. This report provides a detailed discussion of the sources of the 60Co contamination in construction steel, its discovery in the building complexes, and preliminary evaluation and remediation activities.

  17. Temporal and spatial evolution of the solar energetic particle event on 20 January 2005 and resulting radiation doses in aviation

    NASA Astrophysics Data System (ADS)

    Matthiä, D.; Heber, B.; Reitz, G.; Meier, M.; Sihver, L.; Berger, T.; Herbst, K.

    2009-08-01

    The solar energetic particle event on 20 January 2005 was one of the largest ground level events ever observed. Neutron monitor stations in the Antarctic recorded count rate increases of several thousand percent caused by secondary energetic particles, and it took more than 36 h to return to background level. Such huge increases in high energetic solar cosmic radiation on the ground are obviously accompanied by considerable changes in the radiation environment at aviation altitudes. Measurements of 28 neutron monitor stations were used in this work to numerically approximate the primary solar proton spectra during the first 12 h of the event by minimizing the differences between measurements and the results of Monte-Carlo calculated count rate increases. The primary spectrum of solar energetic protons was approximated by a power law in rigidity and a linear angular distribution. The incoming direction of the solar energetic particles was determined and compared to the interplanetary magnetic field direction during the event. The effects on the radiation exposure at altitudes of about 12 km during that time were estimated to range from none at low latitudes up to almost 2 mSv/h for a very short time in the Antarctic region and about 0.1 mSv/h at high latitudes on the Northern Hemisphere. After 12 h, dose rates were still increased by 50% at latitudes above 60° whereas no increases at all occurred at latitudes below 40° during the whole event.

  18. Randomized Trial Comparing Conventional-Dose With High-Dose Conformal Radiation Therapy in Early-Stage Adenocarcinoma of the Prostate: Long-Term Results From Proton Radiation Oncology Group/American College of Radiology 95-09

    PubMed Central

    Zietman, Anthony L.; Bae, Kyounghwa; Slater, Jerry D.; Shipley, William U.; Efstathiou, Jason A.; Coen, John J.; Bush, David A.; Lunt, Margie; Spiegel, Daphna Y.; Skowronski, Rafi; Jabola, B. Rodney; Rossi, Carl J.

    2010-01-01

    Purpose To test the hypothesis that increasing radiation dose delivered to men with early-stage prostate cancer improves clinical outcomes. Patients and Methods Men with T1b-T2b prostate cancer and prostate-specific antigen ≤ 15 ng/mL were randomly assigned to a total dose of either 70.2 Gray equivalents (GyE; conventional) or 79.2 GyE (high). No patient received androgen suppression therapy with radiation. Local failure (LF), biochemical failure (BF), and overall survival (OS) were outcomes. Results A total of 393 men were randomly assigned, and median follow-up was 8.9 years. Men receiving high-dose radiation therapy were significantly less likely to have LF, with a hazard ratio of 0.57. The 10-year American Society for Therapeutic Radiology and Oncology BF rates were 32.4% for conventional-dose and 16.7% for high-dose radiation therapy (P < .0001). This difference held when only those with low-risk disease (n = 227; 58% of total) were examined: 28.2% for conventional and 7.1% for high dose (P < .0001). There was a strong trend in the same direction for the intermediate-risk patients (n = 144; 37% of total; 42.1% v 30.4%, P = .06). Eleven percent of patients subsequently required androgen deprivation for recurrence after conventional dose compared with 6% after high dose (P = .047). There remains no difference in OS rates between the treatment arms (78.4% v 83.4%; P = .41). Two percent of patients in both arms experienced late grade ≥ 3 genitourinary toxicity, and 1% of patients in the high-dose arm experienced late grade ≥ 3 GI toxicity. Conclusion This randomized controlled trial shows superior long-term cancer control for men with localized prostate cancer receiving high-dose versus conventional-dose radiation. This was achieved without an increase in grade ≥ 3 late urinary or rectal morbidity. PMID:20124169

  19. Integrated retrospective radiation dose assessment.

    PubMed

    Goldman, M

    1997-01-01

    Radiation dose reconstruction is used to estimate exposure to radiation that has occurred externally, e.g., from an atomic bomb, or internally, e.g., from radionuclide ingestion. This commentary reviews techniques for biological dosimetry that have been developed to estimate radiation doses from internal exposures, but which can also be used to estimate external exposures. The author argues for increased development and use of these biological tools.

  20. Assessment of the effective dose equivalent for external photon radiation. Volume 1, Calculational results for beam and point source geometries: Final report

    SciTech Connect

    Reece, W.D.; Poston, J.W.; Xu, X.G.

    1993-02-01

    Beginning in January 1994, US nuclear power plants must change the way that they determine the radiation exposure to their workforce. At that time, revisions to Title 10 Part 20 of the Code of Federal Regulations will be in force requiring licensees to evaluate worker radiation exposure using a risk-based methodology termed the ``effective dose equivalent.`` A research project was undertaken to improve upon the conservative method presently used for assessing effective dose equivalent. In this project effective dose equivalent was calculated using a mathematical model of the human body, and tracking photon interactions for a wide variety of radiation source geometries using Monte Carlo computer code simulations. Algorithms were then developed to relate measurements of the photon flux on the surface of the body (as measured by dosimeters) to effective dose equivalent. This report (Volume I of a two-part study) describes: the concept of effective dose equivalent, the evolution of the concept and its incorporation into regulations, the variations in human organ susceptibility to radiation, the mathematical modeling and calculational techniques used, the results of effective dose equivalent calculations for a broad range of photon energiesand radiation source geometries. The study determined that for beam radiation sources the highest effective dose equivalent occurs for beams striking the front of the torso. Beams striking the rear of the torsoproduce the next highest effective dose equivalent, with effective dose equivalent falling significantly as one departs from these two orientations. For point sources, the highest effective dose equivalent occurs when the sources are in contact with the body on the front of the torso. For females the highest effective dose equivalent occurs when the source is on the sternum, for males when it is on the gonads.

  1. Radiation: Doses, Effects, Risks.

    ERIC Educational Resources Information Center

    Lean, Geoffrey, Ed.

    Few scientific issues arouse as much public controversy as the effects of radiation. This booklet is an attempt to summarize what is known about radiation and provide a basis for further discussion and debate. The first four chapters of the booklet are based on the most recent reports to the United Nations' General Assembly by the United Nations…

  2. Recommendations to the Technical Steering Panel regarding approach for estimating individual radiation doses resulting from releases of radionuclides to the Columbia River

    SciTech Connect

    Napier, B.A.; Brothers, A.J.

    1992-07-01

    At the direction of the Technical Steering Panel (TSP) of the Hanford Environmental Dose Reconstruction (HEDR) Project, Battelle staff have reviewed and analyzed available data regarding possible historical radiation doses to individuals resulting from radionuclide releases to the Columbia River. The objective of this review was to recommend to the TSP the spatial and temporal scope and level of effort on Columbia River work to most effectively extend work performed in Phase I of the project (PNL 1991a, PNL 1991b) to meet the project objectives. A number of options were analyzed. Four stretches of the Columbia River and adjacent Pacific coastal waters were defined and investigated for four time periods. Radiation doses arising from ten potentially major exposure pathways were evaluated for each of the time/location combinations, and several alternative methods were defined for estimating the doses from each pathway. Preliminary cost estimates were also developed for implementing dose estimation activities for each of the possible combinations.

  3. Occupational radiation doses during interventional procedures

    NASA Astrophysics Data System (ADS)

    Nuraeni, N.; Hiswara, E.; Kartikasari, D.; Waris, A.; Haryanto, F.

    2016-03-01

    Digital subtraction angiography (DSA) is a type of fluoroscopy technique used in interventional radiology to clearly visualize blood vessels in a bony or dense soft tissue environment. The use of DSA procedures has been increased quite significantly in the Radiology departments in various cities in Indonesia. Various reports showed that both patients and medical staff received a noticeable radiation dose during the course of this procedure. A study had been carried out to measure these doses among interventionalist, nurse and radiographer. The results show that the interventionalist and the nurse, who stood quite close to the X-ray beams compared with the radiographer, received radiation higher than the others. The results also showed that the radiation dose received by medical staff were var depending upon the duration and their position against the X-ray beams. Compared tothe dose limits, however, the radiation dose received by all these three medical staff were still lower than the limits.

  4. Escalated radiation dose alone vs. concurrent chemoradiation for locally advanced and unresectable rectal cancers: results from phase II randomized study.

    PubMed

    Engineer, Reena; Mohandas, K M; Shukla, P J; Shrikhande, S V; Mahantshetty, U; Chopra, S; Goel, M; Mehta, S; Patil, P; Ramadwar, M; Deodhar, K; Arya, S; Shrivastava, Shyam Kishore

    2013-07-01

    This trial was undertaken to compare the rates of resectability between patients treated with neoadjuvant concurrent chemoradiation vs. boosted radiotherapy alone. Patients with clinically unresectable rectal cancer were randomized to receive external beam radiation therapy (EBRT) to pelvis (45 Gy) with concurrent oral Capecitabine (CRT group; Arm 1) or EBRT to pelvis (45 Gy) alone followed by 20 Gy dose of localized radiotherapy boost to the primary tumor site (RT with boost group, Arm 2). All patients were assessed for resectability after 6 weeks by clinical examination and by CT scan and those deemed resectable underwent surgery. A total of 90 patients were randomized, 46 to Arm 1 and 44 to Arm 2. Eighty seven patients (44 in Arm 1 and 41 in Arm 2) completed the prescribed treatment protocol. Overall resectability rate was low in both the groups; R0 resection was achieved in 20 (43 %) patients in Arm 1 vs. 15 (34 %) in Arm 2. Adverse factors that significantly affected the resectability rate in both the groups were extension of tumor to pelvic bones and signet ring cell pathology. Complete pathological response was seen in 7 and 11 %, respectively. There was greater morbidity such as wound infection and delayed wound healing in Arm 2 (16 vs. 40 %; p = 0.03). Escalated radiation dose without chemotherapy does not achieve higher complete (R0) tumor resectability in locally advanced inoperable rectal cancers, compared to concurrent chemoradiation.

  5. Radiation dose optimization in thoracic imaging.

    PubMed

    Tack, D

    2010-01-01

    Guidelines for reduction of CT radiation dose were introduced in 1997 and are now more than 12 years old. The process initiated by the European Regulatory authorities to reduce the excess of radiation from CT has however not produced the expected results. Reference diagnostic levels (DRL) from surveys are still twice as high as needed in most European countries and were not significantly reduced as compared to the initial European ones. Many factors may at least explain partially the lack of dose reduction. One of them is the complexity of the dose optimization process while maintaining image quality at a diagnostically acceptable level. Chest is an anatomical region where radiation dose could be substantially reduced because of high natural contrasts between structures, such as air in the lungs and fat in the mediastinum. In this article, the concept of CT radiation dose optimization and the factors that contribute to maintain global excess in radiation dose are reviewed and a brief summary of results from research in the field of chest CT radiation dose is given.

  6. Effects of Proton Radiation Dose, Dose Rate and Dose Fractionation on Hematopoietic Cells in Mice

    PubMed Central

    Ware, J. H.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X. S.; Rusek, A.; Kennedy, A. R.

    2012-01-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05–0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons. PMID:20726731

  7. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice.

    PubMed

    Ware, J H; Sanzari, J; Avery, S; Sayers, C; Krigsfeld, G; Nuth, M; Wan, X S; Rusek, A; Kennedy, A R

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  8. Effects of proton radiation dose, dose rate and dose fractionation on hematopoietic cells in mice

    SciTech Connect

    Ware, J.H.; Rusek, A.; Sanzari, J.; Avery, S.; Sayers, C.; Krigsfeld, G.; Nuth, M.; Wan, X.S.; Kennedy, A.R.

    2010-09-01

    The present study evaluated the acute effects of radiation dose, dose rate and fractionation as well as the energy of protons in hematopoietic cells of irradiated mice. The mice were irradiated with a single dose of 51.24 MeV protons at a dose of 2 Gy and a dose rate of 0.05-0.07 Gy/min or 1 GeV protons at doses of 0.1, 0.2, 0.5, 1, 1.5 and 2 Gy delivered in a single dose at dose rates of 0.05 or 0.5 Gy/min or in five daily dose fractions at a dose rate of 0.05 Gy/min. Sham-irradiated animals were used as controls. The results demonstrate a dose-dependent loss of white blood cells (WBCs) and lymphocytes by up to 61% and 72%, respectively, in mice irradiated with protons at doses up to 2 Gy. The results also demonstrate that the dose rate, fractionation pattern and energy of the proton radiation did not have significant effects on WBC and lymphocyte counts in the irradiated animals. These results suggest that the acute effects of proton radiation on WBC and lymphocyte counts are determined mainly by the radiation dose, with very little contribution from the dose rate (over the range of dose rates evaluated), fractionation and energy of the protons.

  9. EXOMARS IRAS (DOSE) radiation measurements.

    NASA Astrophysics Data System (ADS)

    Federico, C.; Di Lellis, A. M.; Fonte, S.; Pauselli, C.; Reitz, G.; Beaujean, R.

    The characterization and the study of the radiations on their interaction with organic matter is of great interest in view of the human exploration on Mars. The Ionizing RAdiation Sensor (IRAS) selected in the frame of the ExoMars/Pasteur ESA mission is a lightweight particle spectrometer combining various techniques of radiation detection in space. It characterizes the first time the radiation environment on the Mars surface, and provide dose and dose equivalent rates as precursor information absolutely necessary to develop ways to mitigate the radiation risks for future human exploration on Mars. The Martian radiation levels are much higher than those found on Earth and they are relatively low for space. Measurements on the surface will show if they are similar or not to those seen in orbit (modified by the presence of ``albedo'' neutrons produced in the regolith and by the thin Martian atmosphere). IRAS consists of a telescope based on segmented silicon detectors of about 40\\userk\\milli\\metre\\user;k diameter and 300\\user;k\\micro\\metre\\user;k thickness, a segmented organic scintillator, and of a thermoluminescence dosimeter. The telescope will continuously monitor temporal variation of the particle count rate, the dose rate, particle and LET (Linear Energy Transfer) spectra. Tissue equivalent BC430 scintillator material will be used to measure the neutron dose. Neutrons are selected by a criteria requiring no signal in the anti-coincidence. Last, the passive thermoluminescence dosimeter, based on LiF:Mg detectors, regardless the on board operation timing, will measure the total dose accumulated during the exposure period and due to beta and gamma radiation, with a responsivity very close to that of a human tissue.

  10. Low-dose radiation exposure and carcinogenesis.

    PubMed

    Suzuki, Keiji; Yamashita, Shunichi

    2012-07-01

    Absorption of energy from ionizing radiation by the genetic material in the cell leads to damage to DNA, which in turn leads to cell death, chromosome aberrations and gene mutations. While early or deterministic effects result from organ and tissue damage caused by cell killing, latter two are considered to be involved in the initial events that lead to the development of cancer. Epidemiological studies have demonstrated the dose-response relationships for cancer induction and quantitative evaluations of cancer risk following exposure to moderate to high doses of low-linear energy transfer radiation. A linear, no-threshold model has been applied to assessment of the risks resulting from exposure to moderate and high doses of ionizing radiation; however, a statistically significant increase has hardly been described for radiation doses below 100 mSv. This review summarizes our current knowledge of the physical and biological features of low-dose radiation and discusses the possibilities of induction of cancer by low-dose radiation.

  11. Radiation dose reduction in chest CT: a review.

    PubMed

    Kubo, Takeshi; Lin, Pei-Jan Paul; Stiller, Wolfram; Takahashi, Masaya; Kauczor, Hans-Ulrich; Ohno, Yoshiharu; Hatabu, Hiroto

    2008-02-01

    This article aims to summarize the available data on reducing radiation dose exposure in routine chest CT protocols. First, the general aspects of radiation dose in CT and radiation risk are discussed, followed by the effect of changing parameters on image quality. Finally, the results of previous radiation dose reduction studies are reviewed, and important information contributing to radiation dose reduction will be shared. A variety of methods and techniques for radiation dose reduction should be used to ensure that radiation exposure is kept as low as is reasonably achievable.

  12. Doses from Medical Radiation Sources

    MedlinePlus

    ... that the best approach is to make individual measurements of breast milk activity and individual-specific projections ... 70:437–439; 1997. (5,000 patient dose measurements from 375 hospitals) International Commission on Radiation Protection. ...

  13. Mapping of cosmic radiation dose in Croatia.

    PubMed

    Poje, M; Vuković, B; Radolić, V; Miklavčić, I; Faj, D; Varga Pajtler, M; Planinić, J

    2012-01-01

    The Earth is continually bombarded by high-energy particles coming from the outer space and the sun. These particles, termed cosmic radiation, interact with nuclei of atmospheric constituents and decrease in intensity with depth in the atmosphere. Measurements of photon and gamma radiation, performed with a Radiameter at 1 m above the ground, indicated dose rates of 50-100 nSv/h. The neutron dose rate was measured with the CR-39 track etch detector calibrated by the CERN-EU high-energy Reference Field (CERF) facility. Correlation between neutron dose rates and altitudes at 36 sites was examined in order to obtain a significant positive correlation coefficient; the resulting linear regression enabled estimation of a neutron dose at particular altitude. The measured neutron dose rate in Osijek (altitude of 89 m, latitude of 45.31° N) was 110 nSv/h. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. The Dose Response Relationship for Radiation Carcinogenesis

    NASA Astrophysics Data System (ADS)

    Hall, Eric

    2008-03-01

    case of radiation oncology, modern innovations such as Intensity Modulated Radiation Oncology or Proton Therapy both result in a substantial total-body dose to the patient, which must result in an increased incidence of second cancers. The technology exists to reduce these total body doses and the problem needs to be addressed.

  15. [Results of statistical analysis of the dynamics of ionizing radiation dose fields in the service module of the International Space Station in 2000-2012].

    PubMed

    Mitrikas, V G

    2014-01-01

    The on-going 24th solar cycle (SC) is distinguished from the previous ones by low activity. On the contrary, levels of proton fluxes from galactic cosmic rays (GCR) are high, which increases the proton flow striking the Earth's radiation belts (ERB). Therefore, at present the absorbed dose from ERB protons should be calculated with consideration of the tangible increase of protons intensity built into the model descriptions based on experimental measurements during the minimum between cycles 19 and 20, and the cycle 21 maximum. The absorbed dose from GCR and ERB protons copies galactic protons dynamics, while the ERB electrons dose copies SC dynamics. The major factors that determine the absorbed dose value are SC phase, ISS orbital altitude and shielding of the dosimeter readings of which are used in analysis. The paper presents the results of dynamic analysis of absorbed doses measured by a variety of dosimeters, namely, R-16 (2 ionization chambers), DB8-1, DB8-2, DB8-3, DB8-4 as a function of ISS orbit altitude and SC phase. The existence of annual variation in the absorbed dose dynamics has been confirmed; several additional variations with the periods of 17 and 52 months have been detected. Modulation of absorbed dose variations by the SC and GCR amplitudes has been demonstrated.

  16. Preliminary Results of a Phase 1 Dose-Escalation Trial for Early-Stage Breast Cancer Using 5-Fraction Stereotactic Body Radiation Therapy for Partial-Breast Irradiation.

    PubMed

    Rahimi, Asal; Thomas, Kimberly; Spangler, Ann; Rao, Roshni; Leitch, Marilyn; Wooldridge, Rachel; Rivers, Aeisha; Seiler, Stephen; Albuquerque, Kevin; Stevenson, Stella; Goudreau, Sally; Garwood, Dan; Haley, Barbara; Euhus, David; Heinzerling, John; Ding, Chuxiong; Gao, Ang; Ahn, Chul; Timmerman, Robert

    2017-05-01

    To evaluate the tolerability of a dose-escalated 5-fraction stereotactic body radiation therapy for partial-breast irradiation (S-PBI) in treating early-stage breast cancer after partial mastectomy; the primary objective was to escalate dose utilizing a robotic stereotactic radiation system treating the lumpectomy cavity without exceeding the maximum tolerated dose. Eligible patients included those with ductal carcinoma in situ or invasive nonlobular epithelial histologies and stage 0, I, or II, with tumor size <3 cm. Patients and physicians completed baseline and subsequent cosmesis outcome questionnaires. Starting dose was 30 Gy in 5 fractions and was escalated by 2.5 Gy total for each cohort to 40 Gy. In all, 75 patients were enrolled, with a median age of 62 years. Median follow-up for 5 cohorts was 49.9, 42.5, 25.7, 20.3, and 13.5 months, respectively. Only 3 grade 3 toxicities were experienced. There was 1 dose-limiting toxicity in the overall cohort. Ten patients experienced palpable fat necrosis (4 of which were symptomatic). Physicians scored cosmesis as excellent or good in 95.9%, 100%, 96.7%, and 100% at baseline and 6, 12, and 24 months after S-PBI, whereas patients scored the same periods as 86.5%, 97.1%, 95.1%, and 95.3%, respectively. The disagreement rates between MDs and patients during those periods were 9.4%, 2.9%, 1.6%, and 4.7%, respectively. There have been no recurrences or distant metastases. Dose was escalated to the target dose of 40 Gy in 5 fractions, with the occurrence of only 1 dose-limiting toxicity. Patients felt cosmetic results improved within the first year after surgery and stereotactic body radiation therapy. Our results show minimal toxicity with excellent cosmesis; however, further follow-up is warranted in future studies. This study is the first to show the safety, tolerability, feasibility, and cosmesis results of a 5-fraction dose-escalated S-PBI treatment for early-stage breast cancer in the adjuvant setting

  17. Pediatric CT: Strategies to Lower Radiation Dose

    PubMed Central

    Zacharias, Claudia; Alessio, Adam M.; Otto, Randolph K.; Iyer, Ramesh S.; Philips, Grace S.; Swanson, Jonathan O.; Thapa, Mahesh M.

    2016-01-01

    OBJECTIVE The introduction of MDCT has increased the utilization of CT in pediatric radiology along with concerns for radiation sequelae. This article reviews general principles of lowering radiation dose, the basic physics that impact radiation dose, and specific CT integrated dose-reduction tools focused on the pediatric population. CONCLUSION The goal of this article is to provide a comprehensive review of the recent literature regarding CT dose reduction methods, their limitations, and an outlook on future developments with a focus on the pediatric population. The discussion will initially focus on general considerations that lead to radiation dose reduction, followed by specific technical features that influence the radiation dose. PMID:23617474

  18. Radiation Dose Estimation by Automated Cytogenetic Biodosimetry.

    PubMed

    Rogan, Peter K; Li, Yanxin; Wilkins, Ruth C; Flegal, Farrah N; Knoll, Joan H M

    2016-12-01

    The dose from ionizing radiation exposure can be interpolated from a calibration curve fit to the frequency of dicentric chromosomes (DCs) at multiple doses. As DC counts are manually determined, there is an acute need for accurate, fully automated biodosimetry calibration curve generation and analysis of exposed samples. Software, the Automated Dicentric Chromosome Identifier (ADCI), is presented which detects and discriminates DCs from monocentric chromosomes, computes biodosimetry calibration curves and estimates radiation dose. Images of metaphase cells from samples, exposed at 1.4-3.4 Gy, that had been manually scored by two reference laboratories were reanalyzed with ADCI. This resulted in estimated exposures within 0.4-1.1 Gy of the physical dose. Therefore, ADCI can determine radiation dose with accuracies comparable to standard triage biodosimetry. Calibration curves were generated from metaphase images in ~10 h, and dose estimations required ~0.8 h per 500 image sample. Running multiple instances of ADCI may be an effective response to a mass casualty radiation event. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Biodosimetry and assessment of radiation dose

    PubMed Central

    Crespo, Rafael Herranz; Domene, Mercedes Moreno; Rodríguez, María Jesús Prieto

    2011-01-01

    Aim When investigating radiation accidents, it is very important to determine the exposition dose to the individuals. In the case of exposures over 1 Gy, clinicians may expect deterministic effects arising the following weeks and months, in these cases dose estimation will help physicians in the planning of therapy. Nevertheless, for doses below 1 Gy, biodosimetry data are important due to the risk of developing late stochastic effects. Finally, some accidental overexposures are lack of physical measurements and the only way of quantifying dose is by biological dosimetry. Background The analysis of chromosomal aberrations by different techniques is the most developed method of quantifying dose to individuals exposed to ionising radiations.1,2 Furthermore, the analysis of dicentric chromosomes observed in metaphases from peripheral lymphocytes is the routine technique used in case of acute exposures to assess radiation doses. Materials and methods Solid stain of chromosomes is used to determine dicentric yields for dose estimation. Fluorescence in situ hybridization (FISH) for translocations analysis is used when delayed sampling or suspected chronically irradiation dose assessment. Recommendations in technical considerations are based mainly in the IAEA Technical Report No. 405.2 Results Experience in biological dosimetry at Gregorio Marañón General Hospital is described, including own calibration curves used for dose estimation, background studies and real cases of overexposition. Conclusion Dose assessment by biological dosimeters requires a large previous standardization work and a continuous update. Individual dose assessment involves high qualification professionals and its long time consuming, therefore requires specific Centres. For large mass casualties cooperation among specialized Institutions is needed. PMID:24376970

  20. Low-dose ionizing radiation limitations to seed germination: Results from a model linking physiological characteristics and developmental-dynamics simulation strategy.

    PubMed

    Liu, Hui; Hu, Dawei; Dong, Chen; Fu, Yuming; Liu, Guanghui; Qin, Youcai; Sun, Yi; Liu, Dianlei; Li, Lei; Liu, Hong

    2017-08-01

    There is much uncertainty about the risks of seed germination after repeated or protracted environmental low-dose ionizing radiation exposure. The purpose of this study is to explore the influence mechanism of low-dose ionizing radiation on wheat seed germination using a model linking physiological characteristics and developmental-dynamics simulation. A low-dose ionizing radiation environment simulator was built to investigate wheat (Triticum aestivum L.) seeds germination process and then a kinetic model expressing the relationship between wheat seed germination dynamics and low-dose ionizing radiation intensity variations was developed by experimental data, plant physiology, relevant hypotheses and system dynamics, and sufficiently validated and accredited by computer simulation. Germination percentages were showing no differences in response to different dose rates. However, root and shoot lengths were reduced significantly. Plasma governing equations were set up and the finite element analysis demonstrated H2O, CO2, O2 as well as the seed physiological responses to the low-dose ionizing radiation. The kinetic model was highly valid, and simultaneously the related influence mechanism of low-dose ionizing radiation on wheat seed germination proposed in the modeling process was also adequately verified. Collectively these data demonstrate that low-dose ionizing radiation has an important effect on absorbing water, consuming O2 and releasing CO2, which means the risk for embryo and endosperm development was higher. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Epigenomic Adaptation to Low Dose Radiation

    SciTech Connect

    Gould, Michael N.

    2015-06-30

    The overall hypothesis of this grant application is that the adaptive responses elicited by low dose ionizing radiation (LDIR) result in part from heritable DNA methylation changes in the epigenome. In the final budget period at the University of Wisconsin-Madison, we will specifically address this hypothesis by determining if the epigenetically labile, differentially methylated regions (DMRs) that regulate parental-specific expression of imprinted genes are deregulated in agouti mice by low dose radiation exposure during gestation. This information is particularly important to ascertain given the 1) increased human exposure to medical sources of radiation; 2) increased number of people predicted to live and work in space; and 3) enhanced citizen concern about radiation exposure from nuclear power plant accidents and terrorist ‘dirty bombs.’

  2. Radiation-induced genomic instability: radiation quality and dose response

    NASA Technical Reports Server (NTRS)

    Smith, Leslie E.; Nagar, Shruti; Kim, Grace J.; Morgan, William F.

    2003-01-01

    Genomic instability is a term used to describe a phenomenon that results in the accumulation of multiple changes required to convert a stable genome of a normal cell to an unstable genome characteristic of a tumor. There has been considerable recent debate concerning the importance of genomic instability in human cancer and its temporal occurrence in the carcinogenic process. Radiation is capable of inducing genomic instability in mammalian cells and instability is thought to be the driving force responsible for radiation carcinogenesis. Genomic instability is characterized by a large collection of diverse endpoints that include large-scale chromosomal rearrangements and aberrations, amplification of genetic material, aneuploidy, micronucleus formation, microsatellite instability, and gene mutation. The capacity of radiation to induce genomic instability depends to a large extent on radiation quality or linear energy transfer (LET) and dose. There appears to be a low dose threshold effect with low LET, beyond which no additional genomic instability is induced. Low doses of both high and low LET radiation are capable of inducing this phenomenon. This report reviews data concerning dose rate effects of high and low LET radiation and their capacity to induce genomic instability assayed by chromosomal aberrations, delayed lethal mutations, micronuclei and apoptosis.

  3. Radiation-induced genomic instability: radiation quality and dose response

    NASA Technical Reports Server (NTRS)

    Smith, Leslie E.; Nagar, Shruti; Kim, Grace J.; Morgan, William F.

    2003-01-01

    Genomic instability is a term used to describe a phenomenon that results in the accumulation of multiple changes required to convert a stable genome of a normal cell to an unstable genome characteristic of a tumor. There has been considerable recent debate concerning the importance of genomic instability in human cancer and its temporal occurrence in the carcinogenic process. Radiation is capable of inducing genomic instability in mammalian cells and instability is thought to be the driving force responsible for radiation carcinogenesis. Genomic instability is characterized by a large collection of diverse endpoints that include large-scale chromosomal rearrangements and aberrations, amplification of genetic material, aneuploidy, micronucleus formation, microsatellite instability, and gene mutation. The capacity of radiation to induce genomic instability depends to a large extent on radiation quality or linear energy transfer (LET) and dose. There appears to be a low dose threshold effect with low LET, beyond which no additional genomic instability is induced. Low doses of both high and low LET radiation are capable of inducing this phenomenon. This report reviews data concerning dose rate effects of high and low LET radiation and their capacity to induce genomic instability assayed by chromosomal aberrations, delayed lethal mutations, micronuclei and apoptosis.

  4. Radiation Leukemogenesis at Low Dose Rates

    SciTech Connect

    Weil, Michael; Ullrich, Robert

    2013-09-25

    The major goals of this program were to study the efficacy of low dose rate radiation exposures for the induction of acute myeloid leukemia (AML) and to characterize the leukemias that are caused by radiation exposures at low dose rate. An irradiator facility was designed and constructed that allows large numbers of mice to be irradiated at low dose rates for protracted periods (up to their life span). To the best of our knowledge this facility is unique in the US and it was subsequently used to study radioprotectors being developed for radiological defense (PLoS One. 7(3), e33044, 2012) and is currently being used to study the role of genetic background in susceptibility to radiation-induced lung cancer. One result of the irradiation was expected; low dose rate exposures are ineffective in inducing AML. However, another result was completely unexpected; the irradiated mice had a very high incidence of hepatocellular carcinoma (HCC), approximately 50%. It was unexpected because acute exposures are ineffective in increasing HCC incidence above background. This is a potential important finding for setting exposure limits because it supports the concept of an 'inverse dose rate effect' for some tumor types. That is, for the development of some tumor types low dose rate exposures carry greater risks than acute exposures.

  5. Radiation dose measurements in coronary CT angiography

    PubMed Central

    Sabarudin, Akmal; Sun, Zhonghua

    2013-01-01

    Coronary computed tomography (CT) angiography is associated with high radiation dose and this has raised serious concerns in the literature. Awareness of various parameters for dose estimates and measurements of coronary CT angiography plays an important role in increasing our understanding of the radiation exposure to patients, thus, contributing to the implementation of dose-saving strategies. This article provides an overview of the radiation dose quantity and its measurement during coronary CT angiography procedures. PMID:24392190

  6. Radiation dose-reduction strategies in thoracic CT.

    PubMed

    Moser, J B; Sheard, S L; Edyvean, S; Vlahos, I

    2017-05-01

    Modern computed tomography (CT) machines have the capability to perform thoracic CT for a range of clinical indications at increasingly low radiation doses. This article reviews several factors, both technical and patient-related, that can affect radiation dose and discusses current dose-reduction methods relevant to thoracic imaging through a review of current techniques in CT acquisition and image reconstruction. The fine balance between low radiation dose and high image quality is considered throughout, with an emphasis on obtaining diagnostic quality imaging at the lowest achievable radiation dose. The risks of excessive radiation dose reduction are also considered. Inappropriately low dose may result in suboptimal or non-diagnostic imaging that may reduce diagnostic confidence, impair diagnosis, or result in repeat examinations incurring incremental ionising radiation exposure. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  7. Coronary CT angiography with low radiation dose.

    PubMed

    Xu, Lei; Zhang, Zhaoqi

    2010-02-01

    With the introduction of 64-slice CT and dual-source CT technology, coronary CT angiography(CCTA) has emerged as a useful diagnostic imaging modality for the noninvasive assessment of coronary heart disease. Recently, the risks associated with ionizing radiation on CT have raised serious concerns.The main concern of exposure to ionizing radiation is the potential risk of cancer. CCTA involves much higher radiation dose with the advances in the spatial and temporal resolution of cardiac CT. Currently,various dose-saving algorithms, such as ECG (electrocardiography)-based dose modulation, reduced tube voltage, and prospective ECG gating, high-pitch helical scanning are available to lower radiation exposure during cardiac CT. Therefore, careful selection of CT scanning protocols is needed to keep the radiation exposure 'as low as reasonably achievable (ALARA)'. In this review we will discuss the radiation dose safety issues, the measurement of radiation dose and current use of dose-saving techniques in CCTA.

  8. Awareness of radiation protection and dose levels of imaging procedures among medical students, radiography students, and radiology residents at an academic hospital: Results of a comprehensive survey.

    PubMed

    Faggioni, Lorenzo; Paolicchi, Fabio; Bastiani, Luca; Guido, Davide; Caramella, Davide

    2017-01-01

    To evaluate the awareness of radiation protection issues and the knowledge of dose levels of imaging procedures among medical students, radiology residents, and radiography students at an academic hospital. A total of 159 young doctors and students (including 60 radiology residents, 56 medical students, and 43 radiography students) were issued a questionnaire consisting of 16 multiple choice questions divided into three separated sections (i.e., demographic data, awareness about radiation protection issues, and knowledge about radiation dose levels of common radiological examinations). Medical students claimed to have at least a good knowledge of radiation protection issues more frequently than radiology residents and radiography students (94.4% vs 55% and 35.7%, respectively; P<0.05), with no cases of perceived excellent knowledge among radiography students. However, the actual knowledge of essential radiation protection topics such as regulations, patient and tissue susceptibility to radiation damage, professional radiation risk and dose optimisation, as well as of radiation doses delivered by common radiological procedures was significantly worse among medical students than radiology residents and radiography students (P<0.05). Those latter significantly outperformed radiology residents as to knowledge of radiation protection issues (P<0.01). Overall, less than 50% of survey respondents correctly answered all questions of the survey. Radiology residents, radiography students and medical students have a limited awareness about radiation protection, with a specific gap of knowledge concerning real radiation doses of daily radiological examinations. Both undergraduate and postgraduate teaching needs to be effectively implemented with radiation safety courses. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  9. Dose versus diagnosis: iatrogenic radiation exposure by multidetector computerised tomography in an academic emergency department with measurement of clinically actionable results and emergently treatable findings.

    PubMed

    Baskerville, J R; Chang, J H; Viator, M; Rutledge, W; Miryala, R; Duval, K E; Nishino, T K

    2009-01-01

    To determine the iatrogenic absorbed dosage of radiation of the patient in milligray (mGy) computerised tomography dose index volume (CTDIvol) when tested with multidetector computerised tomography (MDCT) in the emergency department (ED) setting and calculate the absorbed dosage of radiation per clinically actionable result and emergently treatable finding (ETF). The University of Texas Medical Branch (UTMB) ED located in Galveston, Texas, USA, is a level 1 trauma and tertiary referral centre treating 70,000 patients per annum. A retrospective cross-sectional data analysis of 770 emergency patients investigated by MDCT in July 2007. The presence of actionable results and ETF were determined by chart review. A total of 5320 emergency patients was treated in the UTMB ED in July 2007. This included 4508 medical and 812 trauma patients. A total of 1094 MDCT studies was performed, of which complete data were available on 1046. A total of 770 patients was investigated by MDCT, representing 14.47% of all emergency patients. This included 33.99% of trauma patients and 10.96% of medical patients. Actionable results were found in 341 studies and ETF in 105 studies. The mean radiation was 163.27 and 530.23 mGy CTDIvol for actionable results and ETF, respectively, for all studies. The mean radiation was 53.27 and 106.36 mGy CTDIvol for medical and trauma patients, respectively. The absorbed dosage of radiation of patients investigated by MDCT is clinically significant. The actionable results and ETF in our study demonstrate considerable opportunity for improvement in the utilisation of this technology by physicians.

  10. Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi-centre diagnostic reference level in Queensland public hospitals

    PubMed Central

    Crowhurst, James A; Whitby, Mark; Thiele, David; Halligan, Toni; Westerink, Adam; Crown, Suzanne; Milne, Jillian

    2014-01-01

    Introduction Radiation dose to patients undergoing invasive coronary angiography (ICA) is relatively high. Guidelines suggest that a local benchmark or diagnostic reference level (DRL) be established for these procedures. This study sought to create a DRL for ICA procedures in Queensland public hospitals. Methods Data were collected for all Cardiac Catheter Laboratories in Queensland public hospitals. Data were collected for diagnostic coronary angiography (CA) and single-vessel percutaneous intervention (PCI) procedures. Dose area product (PKA), skin surface entrance dose (KAR), fluoroscopy time (FT), and patient height and weight were collected for 3 months. The DRL was set from the 75th percentile of the PKA. Results 2590 patients were included in the CA group where the median FT was 3.5 min (inter-quartile range = 2.3–6.1). Median KAR = 581 mGy (374–876). Median PKA = 3908 uGym2 (2489–5865) DRL = 5865 uGym2. 947 patients were included in the PCI group where median FT was 11.2 min (7.7–17.4). Median KAR = 1501 mGy (928–2224). Median PKA = 8736 uGym2 (5449–12,900) DRL = 12,900 uGym2. Conclusion This study established a benchmark for radiation dose for diagnostic and interventional coronary angiography in Queensland public facilities. PMID:26229649

  11. Esophageal self-expandable stent material and mesh grid density are the major determining factors of external beam radiation dose perturbation: results from a phantom model.

    PubMed

    Abu Dayyeh, B K; Vandamme, J J; Miller, R C; Baron, T H

    2013-01-01

    Self-expandable esophageal stents are increasingly used for palliation or as an adjunct to chemoradiation for esophageal neoplasia. The optimal esophageal stent design and material to minimize dose perturbation with external beam radiation are unknown. We sought to quantify the deviation from intended radiation dose as a function of stent material and mesh density design. A laboratory dosimetric film model was used to quantify perturbation of intended radiation dose among 16 different esophageal stents with varying material and stent mesh density design. Radiation dose enhancement due to stent backscatter ranged from 0 % to 7.3 %, collectively representing a standard difference from the intended mean radiation dose of 1.9 (95 % confidence interval [CI] 1.5 - 2.2). This enhancement was negligible for polymer-based stents and approached 0 % for the biodegradable stents. In contrast, all metal alloy stents had significant radiation backscatter; this was largely determined by the density of mesh design and not by the type of alloy used. Stent characteristics should be considered when selecting the optimal stent for treatment and palliation of malignant esophageal strictures, especially when adjuvant or neo-adjuvant radiotherapy is planned. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Estimated radiation dose from timepieces containing tritium

    SciTech Connect

    McDowell-Boyer, L M

    1980-01-01

    Luminescent timepieces containing radioactive tritium, either in elemental form or incorporated into paint, are available to the general public. The purpose of this study was to estimate potential radiation dose commitments received by the public annually as a result of exposure to tritium which may escape from the timepieces during their distribution, use, repair, and disposal. Much uncertainty is associated with final dose estimates due to limitations of empirical data from which exposure parameters were derived. Maximum individual dose estimates were generally less than 3 ..mu..Sv/yr, but ranged up to 2 mSv under worst-case conditions postulated. Estimated annual collective (population) doses were less than 5 person/Sv per million timepieces distributed.

  13. Radiation Dose Optimization For Critical Organs

    NASA Astrophysics Data System (ADS)

    Khodadadegan, Yasaman

    Ionizing radiation used in the patient diagnosis or therapy has negative effects on the patient body in short term and long term depending on the amount of exposure. More than 700,000 examinations are everyday performed on Interventional Radiology modalities, however; there is no patient-centric information available to the patient or the Quality Assurance for the amount of organ dose received. In this study, we are exploring the methodologies to systematically reduce the absorbed radiation dose in the Fluoroscopically Guided Interventional Radiology procedures. In the first part of this study, we developed a mathematical model which determines a set of geometry settings for the equipment and a level for the energy during a patient exam. The goal is to minimize the amount of absorbed dose in the critical organs while maintaining image quality required for the diagnosis. The model is a large-scale mixed integer program. We performed polyhedral analysis and derived several sets of strong inequalities to improve the computational speed and quality of the solution. Results present the amount of absorbed dose in the critical organ can be reduced up to 99% for a specific set of angles. In the second part, we apply an approximate gradient method to simultaneously optimize angle and table location while minimizing dose in the critical organs with respect to the image quality. In each iteration, we solve a sub-problem as a MIP to determine the radiation field size and corresponding X-ray tube energy. In the computational experiments, results show further reduction (up to 80%) of the absorbed dose in compare with previous method. Last, there are uncertainties in the medical procedures resulting imprecision of the absorbed dose. We propose a robust formulation to hedge from the worst case absorbed dose while ensuring feasibility. In this part, we investigate a robust approach for the organ motions within a radiology procedure. We minimize the absorbed dose for the critical

  14. CT radiation dose awareness among paediatricians.

    PubMed

    Al-Rammah, Tamader Y

    2016-08-31

    The radiation dose delivered from computed tomography (CT) scanning and the risks associated with ionising radiation are major concerns in paediatric imaging. Compared to adults, children have increased organ sensitivity and a longer expected lifetime in which cancer may develop. Therefore, it is important to investigate the awareness of paediatricians (referring physicians) regarding radiation doses and the associated risks. A multiple-choice survey was distributed among paediatricians in 8 hospitals in Riyadh, the capital of Saudi Arabia. Among the 162 respondents, only 24 (15 %) were aware of the As Low As Reasonably Achievable (ALARA) principle. Approximately half (54 %) of the respondents believed that multi-slice CT delivered a low radiation dose, and 100 (62 %) of the respondents were not aware that radiation is considered carcinogenic by the Food and Drug Administration in the United States. Among the respondents, 110 (68 %) did not have any specific education regarding radiation during their training. There was an overall underestimation (83 %) of the CT radiation dose, and 70 % thought that magnetic resonance imaging (MRI) delivered some level of ionising radiation. Among paediatricians in Saudi Arabian hospitals, there was a wide underestimation of the CT radiation dose and the associated risks for children. We should improve paediatricians' knowledge about radiation doses. Radiologists, paediatricians, radiation technologists and medical physicists should work together to optimise CT guidelines and protocols to reduce the radiation risks for children.

  15. Very Low Dose Fetal Exposure to Chernobyl Contamination Resulted in Increases in Infant Leukemia in Europe and Raises Questions about Current Radiation Risk Models

    PubMed Central

    Busby, Christopher C.

    2009-01-01

    Following contamination from the Chernobyl accident in April 1986 excess infant leukemia (0–1 y) was reported from five different countries, Scotland, Greece, Germany, Belarus and Wales and Scotland combined. The cumulative absorbed doses to the fetus, as conventionally assessed, varied from 0.02 mSv in the UK through 0.06 mSv in Germany, 0.2 mSv in Greece and 2 mSv in Belarus, where it was highest. Nevertheless, the effect was real and given the specificity of the cohort raised questions about the safety of applying the current radiation risk model of the International Commission on Radiological Protection (ICRP) to these internal exposures, a matter which was discussed in 2000 by Busby and Cato [7,8] and also in the reports of the UK Committee examining Radiation Risk from Internal Emitters. Data on infant leukemia in the United Kingdom, chosen on the basis of the cohorts defined by the study of Greece were supplied by the UK Childhood Cancer Research Group. This has enabled a study of leukemia in the combined infant population of 15,466,845 born in the UK, Greece, and Germany between 1980 and 1990. Results show a statistically significant excess risk RR = 1.43 (95% CI 1.13 < RR < 1.80 (2-tailed); p = 0.0025) in those born during the defined peak exposure period of 01/07/86 to 31/12/87 compared with those born between 01/01/80 and 31/12/85 and 01/01/88 and 31/12/90. The excess risks in individual countries do not increase monotonically with the conventionally calculated doses, the relation being biphasic, increasing sharply at low doses and falling at high doses. This result is discussed in relation to fetal/cell death at higher doses and also to induction of DNA repair. Since the cohort is chosen specifically on the basis of exposure to internal radionuclides, the result can be expressed as evidence for a significant error in the conventional modeling for such internal fetal exposures. PMID:20049249

  16. Risk of Late Toxicity in Men Receiving Dose-Escalated Hypofractionated Intensity Modulated Prostate Radiation Therapy: Results From a Randomized Trial

    SciTech Connect

    Hoffman, Karen E. Voong, K. Ranh; Pugh, Thomas J.; Skinner, Heath; Levy, Lawrence B.; Takiar, Vinita; Choi, Seungtaek; Du, Weiliang; Frank, Steven J.; Johnson, Jennifer; Kanke, James; Kudchadker, Rajat J.; Lee, Andrew K.; Mahmood, Usama; McGuire, Sean E.; Kuban, Deborah A.

    2014-04-01

    Objective: To report late toxicity outcomes from a randomized trial comparing conventional and hypofractionated prostate radiation therapy and to identify dosimetric and clinical parameters associated with late toxicity after hypofractionated treatment. Methods and Materials: Men with localized prostate cancer were enrolled in a trial that randomized men to either conventionally fractionated intensity modulated radiation therapy (CIMRT, 75.6 Gy in 1.8-Gy fractions) or to dose-escalated hypofractionated IMRT (HIMRT, 72 Gy in 2.4-Gy fractions). Late (≥90 days after completion of radiation therapy) genitourinary (GU) and gastrointestinal (GI) toxicity were prospectively evaluated and scored according to modified Radiation Therapy Oncology Group criteria. Results: 101 men received CIMRT and 102 men received HIMRT. The median age was 68, and the median follow-up time was 6.0 years. Twenty-eight percent had low-risk, 71% had intermediate-risk, and 1% had high-risk disease. There was no difference in late GU toxicity in men treated with CIMRT and HIMRT. The actuarial 5-year grade ≥2 GU toxicity was 16.5% after CIMRT and 15.8% after HIMRT (P=.97). There was a nonsignificant numeric increase in late GI toxicity in men treated with HIMRT compared with men treated with CIMRT. The actuarial 5-year grade ≥2 GI toxicity was 5.1% after CIMRT and 10.0% after HIMRT (P=.11). In men receiving HIMRT, the proportion of rectum receiving 36.9 Gy, 46.2 Gy, 64.6 Gy, and 73.9 Gy was associated with the development of late GI toxicity (P<.05). The 5-year actuarial grade ≥2 GI toxicity was 27.3% in men with R64.6Gy ≥ 20% but only 6.0% in men with R64.6Gy < 20% (P=.016). Conclusions: Dose-escalated IMRT using a moderate hypofractionation regimen (72 Gy in 2.4-Gy fractions) can be delivered safely with limited grade 2 or 3 late toxicity. Minimizing the proportion of rectum that receives moderate and high dose decreases the risk of late rectal toxicity after this

  17. Hypofractionated High-Dose Radiation Therapy for Prostate Cancer: Long-Term Results of a Multi-Institutional Phase II Trial

    SciTech Connect

    Fonteyne, Valerie; Soete, Guy; Arcangeli, Stefano; De Neve, Wilfried; Rappe, Bernard; Storme, Guy; Strigari, Lidia; Arcangeli, Giorgio; De Meerleer, Gert

    2012-11-15

    Purpose: To report late gastrointestinal (GI) and genitourinary (GU) toxicity, biochemical and clinical outcomes, and overall survival after hypofractionated radiation therapy for prostate cancer (PC). Methods and Materials: Three institutions included 113 patients with T1 to T3N0M0 PC in a phase II study. Patients were treated with 56 Gy in 16 fractions over 4 weeks. Late toxicity was scored using Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer criteria extended with additional symptoms. Biochemical outcome was reported according to the Phoenix definition for biochemical failure. Results: The incidence of late GI and GU toxicity was low. The 3-year actuarial risk of developing late GU and GI toxicity of grade {>=}2 was 13% and 8% respectively. Five-year biochemical non-evidence of disease (bNED) was 94%. Risk group, T stage, and deviation from planned hormone treatment were significant predictive factors for bNED. Deviation from hormone treatment remained significant in multivariate analysis. Five-year clinical non evidence of disease and overall survival was 95% and 91% respectively. No patient died from PC. Conclusions: Hypofractionated high-dose radiation therapy is a valuable treatment option for patients with PC, with excellent biochemical and clinical outcome and low toxicity.

  18. A Novel Form of Breast Intraoperative Radiation Therapy With CT-Guided High-Dose-Rate Brachytherapy: Results of a Prospective Phase 1 Clinical Trial.

    PubMed

    Showalter, Shayna L; Petroni, Gina; Trifiletti, Daniel M; Libby, Bruce; Schroen, Anneke T; Brenin, David R; Dalal, Parchayi; Smolkin, Mark; Reardon, Kelli A; Showalter, Timothy N

    2016-09-01

    Existing intraoperative radiation therapy (IORT) techniques are criticized for the lack of image guided treatment planning and energy deposition with, at times, poor resultant dosimetry and low radiation dose. We pioneered a novel method of IORT that incorporates customized, computed tomography (CT)-based treatment planning and high-dose-rate (HDR) brachytherapy to overcome these drawbacks: CT-HDR-IORT. A phase 1 study was conducted to demonstrate the feasibility and safety of CT-HDR-IORT. Eligibility criteria included age ≥50 years, invasive or in situ breast cancer, tumor size <3 cm, and N0 disease. Patients were eligible before or within 30 days of breast-conserving surgery (BCS). BCS was performed, and a multilumen balloon catheter was placed. CT images were obtained, a customized HDR brachytherapy plan was created, and a dose of 12.5 Gy was delivered to 1-cm depth from the balloon surface. The catheter was removed, and the skin was closed. The primary endpoints were feasibility and acute toxicity. Feasibility was defined as IORT treatment interval (time from CT acquisition until IORT completion) ≤90 minutes. The secondary endpoints included dosimetry, cosmetic outcome, quality of life, and late toxicity. Twenty-eight patients were enrolled. The 6-month follow-up assessments were completed by 93% of enrollees. The median IORT treatment interval was 67.2 minutes (range, 50-108 minutes). The treatment met feasibility criteria in 26 women (93%). The dosimetric goals were met in 22 patients (79%). There were no Radiation Therapy Oncology Group grade 3+ toxicities; 6 patients (21%) experienced grade 2 events. Most patients (93%) had good/excellent cosmetic outcomes at the last follow-up visit. CT-HDR-IORT is feasible and safe. This promising approach for a conformal, image-based, higher-dose breast IORT is being evaluated in a phase 2 trial. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. SU-C-18C-06: Radiation Dose Reduction in Body Interventional Radiology: Clinical Results Utilizing a New Imaging Acquisition and Processing Platform

    SciTech Connect

    Kohlbrenner, R; Kolli, KP; Taylor, A; Kohi, M; Fidelman, N; LaBerge, J; Kerlan, R; Gould, R

    2014-06-01

    Purpose: To quantify the patient radiation dose reduction achieved during transarterial chemoembolization (TACE) procedures performed in a body interventional radiology suite equipped with the Philips Allura Clarity imaging acquisition and processing platform, compared to TACE procedures performed in the same suite equipped with the Philips Allura Xper platform. Methods: Total fluoroscopy time, cumulative dose area product, and cumulative air kerma were recorded for the first 25 TACE procedures performed to treat hepatocellular carcinoma (HCC) in a Philips body interventional radiology suite equipped with Philips Allura Clarity. The same data were collected for the prior 85 TACE procedures performed to treat HCC in the same suite equipped with Philips Allura Xper. Mean values from these cohorts were compared using two-tailed t tests. Results: Following installation of the Philips Allura Clarity platform, a 42.8% reduction in mean cumulative dose area product (3033.2 versus 1733.6 mGycm∧2, p < 0.0001) and a 31.2% reduction in mean cumulative air kerma (1445.4 versus 994.2 mGy, p < 0.001) was achieved compared to similar procedures performed in the same suite equipped with the Philips Allura Xper platform. Mean total fluoroscopy time was not significantly different between the two cohorts (1679.3 versus 1791.3 seconds, p = 0.41). Conclusion: This study demonstrates a significant patient radiation dose reduction during TACE procedures performed to treat HCC after a body interventional radiology suite was converted to the Philips Allura Clarity platform from the Philips Allura Xper platform. Future work will focus on evaluation of patient dose reduction in a larger cohort of patients across a broader range of procedures and in specific populations, including obese patients and pediatric patients, and comparison of image quality between the two platforms. Funding for this study was provided by Philips Healthcare, with 5% salary support provided to authors K. Pallav

  20. Radiation Doses to Members of the U.S. Population from Ubiquitous Radionuclides in the Body: Part 3, Results, Variability, and Uncertainty

    SciTech Connect

    Watson, David J.; Strom, Daniel J.

    2011-02-25

    This paper is part three of a three-part series investigating annual effective doses to residents of the United States from intakes of ubiquitous radionuclides, including radionuclides occurring naturally, radionuclides whose concentrations are technologically enhanced, and anthropogenic radionuclides. The radionuclides of interest are the 238U series (14 nuclides), the actinium series (headed by 235U; 11 nuclides), and the 232Th series (11 nuclides); primordial radionuclides 87Rb and 40K; cosmogenic and fallout radionuclides 14C and 3H; and purely anthropogenic radionuclides 137Cs-137mBa, 129I and 90Sr-90Y. This series of papers explicitly excludes intakes from inhaling 222Rn, 220Rn, and their short-lived decay products; it also excludes intakes of radionuclides in occupational and medical settings. Part one reviewed, summarized, characterized, and grouped all published and some unpublished data for U.S. residents on ubiquitous radionuclide concentrations in tissues and organs. Part two described the methods used to organize the data collected in part one and segregate it into the ages and genders defined by the study, imputed missing values from the existing data, apportioned activity in bone, and imputed activity in hollow organ contents and the remainder of the body. This paper estimates equivalent doses to target tissues from source regions and maps target tissues to lists of tissues with International Commission on Radiation Protection (ICRP) tissue-weighting factors or to surrogate tissue regions when there is no direct match. Effective doses, using ICRP tissue-weighting factors recommended in 1977, 1990, and 2007, are then calculated, and an upper bound of variability of the effective dose is estimated by calculating the average coefficients of variation (CV), assuming all variance is due to variability. Most of the data were for adult males, whose average annual effective dose is estimated to be 337 μSv (CV = 0.65, geometric mean = 283 μSv, geometric

  1. Low-dose radiation epidemiology studies: status and issues.

    PubMed

    Shore, Roy E

    2009-11-01

    Although the Japanese atomic bomb study and radiotherapy studies have clearly documented cancer risks from high-dose radiation exposures, radiation risk assessment groups have long recognized that protracted or low exposures to low-linear energy transfer radiations are key radiation protection concerns because these are far more common than high-exposure scenarios. Epidemiologic studies of human populations with low-dose or low dose-rate exposures are one approach to addressing those concerns. A number of large studies of radiation workers (Chernobyl clean-up workers, U.S. and Chinese radiological technologists, and the 15-country worker study) or of persons exposed to environmental radiation at moderate to low levels (residents near Techa River, Semipalatinsk, Chernobyl, or nuclear facilities) have been conducted. A variety of studies of medical radiation exposures (multiple-fluoroscopy, diagnostic (131)I, scatter radiation doses from radiotherapy, etc.) also are of interest. Key results from these studies are summarized and compared with risk estimates from the Japanese atomic bomb study. Ideally, one would like the low-dose and low dose-rate studies to guide radiation risk estimation regarding the shape of the dose-response curve, DDREF (dose and dose-rate effectiveness factor), and risk at low doses. However, the degree to which low-dose studies can do so is subject to various limitations, especially those pertaining to dosimetric uncertainties and limited statistical power. The identification of individuals who are particularly susceptible to radiation cancer induction also is of high interest in terms of occupational and medical radiation protection. Several examples of studies of radiation-related cancer susceptibility are discussed, but none thus far have clearly identified radiation-susceptible genotypes.

  2. ["Dose-risk" relationships at low doses of radiation].

    PubMed

    Stefanou, E P

    1988-01-01

    The ionizing radiation is inherently harmful to human beings, and people must be protected from unnecessary or excessive exposure to it. The harmful nature of high doses of x rays has been known for many years. However, for low doses such as those commonly employed in dental radiographic procedures the magnitude of the risk (or even if there is a risk) remains uncertain. The purpose of this paper is to do an analysis of the Dose-risk relationships at low doses of radiation according to the latest recommendations and philosophy of the International Commission on Radiological Protection (ICRP).

  3. Potential radiation doses from 1994 Hanford Operations

    SciTech Connect

    Soldat, J.K.; Antonio, E.J.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the potential radiation doses to the public from releases originating at the Hanford Site. Members of the public are potentially exposed to low-levels of radiation from these effluents through a variety of pathways. The potential radiation doses to the public were calculated for the hypothetical MEI and for the general public residing within 80 km (50 mi) of the Hanford Site.

  4. Measurement of dose in radionuclide therapy by using Cerenkov radiation.

    PubMed

    Ai, Yao; Tang, Xiaobin; Shu, Diyun; Shao, Wencheng; Gong, Chunhui; Geng, Changran; Zhang, Xudong; Yu, Haiyan

    2017-08-14

    This work aims to determine the relationship between Cerenkov photon emission and radiation dose from internal radionuclide irradiation. Water and thyroid phantoms were used to simulate the distribution of Cerenkov photon emission and dose deposition through Monte Carlo method. The relationship between Cerenkov photon emission and dose deposition was quantitatively analyzed. A neck phantom was also used to verify Cerenkov photon detection for thyroid radionuclide therapy. Results show that Cerenkov photon emission and dose deposition exhibit the same distribution pattern in water phantom, and this relative distribution relationship also existed in the thyroid phantom. Moreover, Cerenkov photon emission exhibits a specific quantitative relation to dose deposition. For thyroid radionuclide therapy, only a part of Cerenkov photon produced by thyroid could penetrate the body for detection; therefore, the use of Cerenkov radiation for measurement of radionuclide therapy dose may be more suitable for superficial tumors. This study demonstrated that Cerenkov radiation has the potential to be used for measuring radiation dose for radionuclide therapy.

  5. Breast cancer risk from low-dose exposures to ionizing radiation: results of parallel analysis of three exposed populations of women

    SciTech Connect

    Land, C.E.; Boice, J.D. Jr.; Shore, R.E.; Norman, J.E.; Tokunaga, M.

    1980-08-01

    Breast cancer incidence data were analyzed from three populations of women exposed to ionizing radiation: survivors of the Hiroshima and Nagasaki atomic bombs, patients in Massachusetts tuberculosis sanitoria who were exposed to multiple chest fluoroscopies, and patients treated by X-rays for acute postpartum mastitis in Rochester, New York. Parallel analyses by radiation dose, age at exposure, and time after exposure suggested that risk of radiation-induced cancer increased approximately linearly with increasing dose and was heavily dependent on age at exposure; however, the risk was otherwise remarkably similar among the three populations, at least for ages 10 to 40 years at exposure, and followed the same temporal pattern of occurrence as did breast cancer incidence in nonexposed women of similar ages.

  6. Adaption By Low Dose Radiation Exposure

    PubMed Central

    2015-01-01

    The procedures and dose limitations used for radiation protection in the nuclear industry are founded on the assumption that risk is directly proportional to dose, without a threshold. Based on this idea that any dose, no matter how small, will increase risk, radiation protection regulations generally attempt to reduce any exposure to “as low as reasonably achievable” (ALARA). We know however, that these regulatory assumptions are inconsistent with the known biological effects of low doses. Low doses induce protective effects, and these adaptive responses are part of a general response to low stress. Adaptive responses have been tightly conserved during evolution, from single celled organisms up to humans, indicating their importance. Here we examine cellular and animal studies that show the influence of radiation induced protective effects on diverse diseases, and examine the radiation dose range that is effective for different tissues in the same animal. The concept of a dose window, with upper and lower effective doses, as well as the effect of multiple stressors and the influence of genetics will also be examined. The effect of the biological variables on low dose responses will be considered from the point of view of the limitations they may impose on any revised radiation protection regulations. PMID:26672725

  7. Radiation dose estimates for copper-64 citrate in man

    SciTech Connect

    Crook, J.E.; Carlton, J.E.; Stabin, M.; Watson, E.

    1985-01-01

    Tumor imaging agents suitable for use with positron emission tomographs are constantly sought. We have performed studies with animal-tumor-bearing models that have demonstrated the rapid uptake of copper-64. The radiation dose estimates for man indicate that the intravenous administration of 7.0 mCi would result in radiation doses to the kidney of 9.8 to 10.5 rads with other organs receiving substantially less radiation. 5 refs., 3 tabs.

  8. Radiation dose rates from UF{sub 6} cylinders

    SciTech Connect

    Friend, P.J.

    1991-12-31

    This paper describes the results of many studies, both theoretical and experimental, which have been carried out by Urenco over the last 15 years into radiation dose rates from uranium hexafluoride (UF{sub 6}) cylinders. The contents of the cylinder, its history, and the geometry all affect the radiation dose rate. These factors are all examined in detail. Actual and predicted dose rates are compared with levels permitted by IAEA transport regulations.

  9. Radiation dose distributions due to sudden ejection of cobalt device.

    PubMed

    Abdelhady, Amr

    2016-09-01

    The evaluation of the radiation dose during accident in a nuclear reactor is of great concern from the viewpoint of safety. One of important accident must be analyzed and may be occurred in open pool type reactor is the rejection of cobalt device. The study is evaluating the dose rate levels resulting from upset withdrawal of co device especially the radiation dose received by the operator in the control room. Study of indirect radiation exposure to the environment due to skyshine effect is also taken into consideration in order to evaluate the radiation dose levels around the reactor during the ejection trip. Microshield, SHLDUTIL, and MCSky codes were used in this study to calculate the radiation dose profiles during cobalt device ejection trip inside and outside the reactor building. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Low Dose Ionizing Radiation Modulates Immune Function

    SciTech Connect

    Nelson, Gregory A.

    2016-01-12

    In order to examine the effects of low dose ionizing radiation on the immune system we chose to examine an amplified adaptive cellular immunity response. This response is Type IV delayed-type hypersensitivity also called contact hypersensitivity. The agent fluorescein isothiocyanate (FITC) is a low molecular weight, lipophilic, reactive, fluorescent molecule that can be applied to the skin where it (hapten) reacts with proteins (carriers) to become a complete antigen. Exposure to FITC leads to sensitization which is easily measured as a hypersensitivity inflammatory reaction following a subsequent exposure to the ear. Ear swelling, eosinophil infiltration, immunoglobulin E production and cytokine secretion patterns characteristic of a “Th2 polarized” immune response are the components of the reaction. The reaction requires successful implementation of antigen processing and presentation by antigen presenting Langerhans cells, communication with naïve T lymphocytes in draining lymph nodes, expansion of activated T cell clones, migration of activated T cells to the circulation, and recruitment of memory T cells, macrophages and eosinophils to the site of the secondary challenge. Using this model our approach was to quantify system function rather than relying only on indirect biomarkers of cell. We measured the FITC-induced hypersensitivity reaction over a range of doses from 2 cGy to 2 Gy. Irradiations were performed during key events or prior to key events to deplete critical cell populations. In addition to quantifying the final inflammatory response, we assessed cell populations in peripheral blood and spleen, cytokine signatures, IgE levels and expression of genes associated with key processes in sensitization and elicitation/recall. We hypothesized that ionizing radiation would produce a biphasic effect on immune system function resulting in an enhancement at low doses and a depression at higher doses and suggested that this transition would occur in the

  11. Impact of dose and volume on radiation-induced mucositis.

    PubMed

    Mantini, Giovanna; Manfrida, Stefania; Cellini, Francesco; Giammarino, Daniela; Petrone, Adelina; Vitucci, Pasquale; Cellini, Numa

    2005-01-01

    There is a relationship between a given radiation dose and the resulting biological effect in the management of head and neck cancer. Radiation mucositis represents a frequent complication in cancer chemoradiation. Its prevention and treatment are major goals in radiation therapy schedules. Critical tissues can be spared using high conformal radiation therapy (3DCRT) based on consensus guidelines for target volume. Current approaches to radiation mucositis with respect to the dose and volume impact are illustrated. The monitoring system of late toxicity used by the authors is presented.

  12. The impact of x-ray tube stabilization on localized radiation dose in axial CT scans: initial results in CTDI phantoms

    NASA Astrophysics Data System (ADS)

    Mathieu, Kelsey B.; McNitt-Gray, Michael F.; Cody, Dianna D.

    2016-10-01

    Rise, fall, and stabilization of the x-ray tube output occur immediately before and after data acquisition on some computed tomography (CT) scanners and are believed to contribute additional dose to anatomy facing the x-ray tube when it powers on or off. In this study, we characterized the dose penalty caused by additional radiation exposure during the rise, stabilization, and/or fall time (referred to as overscanning). A 32 cm CT dose-index (CTDI) phantom was scanned on three CT scanners: GE Healthcare LightSpeed VCT, GE Healthcare Discovery CT750 HD, and Siemens Somatom Definition Flash. Radiation exposure was detected for various x-ray tube start acquisition angles using a 10 cm pencil ionization chamber placed in the peripheral chamber hole at the phantom’s 12 o’clock position. Scan rotation time, ionization chamber location, phantom diameter, and phantom centering were varied to quantify their effects on the dose penalty caused by overscanning. For 1 s single, axial rotations, CTDI at the 12 o’clock chamber position (CTDI100, 12:00) was 6.1%, 4.0%, and 4.4% higher when the start angle of the x-ray tube was aligned at the top of the gantry (12 o’clock) versus when the start angle was aligned at 9 o’clock for the Siemens Flash, GE CT750 HD, and GE VCT scanner, respectively. For the scanners’ fastest rotation times (0.285 s for the Siemens and 0.4 s for both GE scanners), the dose penalties increased to 22.3%, 10.7%, and 10.5%, respectively, suggesting a trade-off between rotation speed and the dose penalty from overscanning. In general, overscanning was shown to have a greater radiation dose impact for larger diameter phantoms, shorter rotation times, and to peripheral phantom locations. Future research is necessary to determine an appropriate method for incorporating the localized dose penalty from overscanning into standard dose metrics, as well as to assess the impact on organ dose.

  13. Radiation dose to the global flying population.

    PubMed

    Alvarez, Luis E; Eastham, Sebastian D; Barrett, Steven R H

    2016-03-01

    Civil airliner passengers and crew are exposed to elevated levels of radiation relative to being at sea level. Previous studies have assessed the radiation dose received in particular cases or for cohort studies. Here we present the first estimate of the total radiation dose received by the worldwide civilian flying population. We simulated flights globally from 2000 to 2013 using schedule data, applying a radiation propagation code to estimate the dose associated with each flight. Passengers flying in Europe and North America exceed the International Commission on Radiological Protection annual dose limits at an annual average of 510 or 420 flight hours per year, respectively. However, this falls to 160 or 120 h on specific routes under maximum exposure conditions.

  14. Patient Radiation Doses from Diagnostic Radiology.

    ERIC Educational Resources Information Center

    Hart, D.

    1996-01-01

    Explains how x-ray doses to patients are measured. Describes how different techniques expose patients to differing amounts of ionizing radiation. Compares these figures with other natural and man-made sources. (Author/MKR)

  15. Gamma Radiation Doses In Sweden

    SciTech Connect

    Almgren, Sara; Isaksson, Mats; Barregaard, Lars

    2008-08-07

    Gamma dose rate measurements were performed in one urban and one rural area using thermoluminescence dosimeters (TLD) worn by 46 participants and placed in their dwellings. The personal effective dose rates were 0.096{+-}0.019(1 SD) and 0.092{+-}0.016(1 SD){mu}Sv/h in the urban and rural area, respectively. The corresponding dose rates in the dwellings were 0.11{+-}0.042(1 SD) and 0.091{+-}0.026(1 SD){mu}Sv/h. However, the differences between the areas were not significant. The values were higher in buildings made of concrete than of wood and higher in apartments than in detached houses. Also, {sup 222}Rn measurements were performed in each dwelling, which showed no correlation with the gamma dose rates in the dwellings.

  16. A Phase I/II Radiation Dose Escalation Study With Concurrent Chemotherapy for Patients With Inoperable Stages I to III Non-Small-Cell Lung Cancer: Phase I Results of RTOG 0117

    SciTech Connect

    Bradley, Jeffrey D.; Moughan, Jennifer; Graham, Mary V.; Byhardt, Roger; Govindan, Ramaswamy; Fowler, Jack; Purdy, James A.; Michalski, Jeff M.; Gore, Elizabeth; Choy, Hak

    2010-06-01

    Purpose: In preparation for a Phase III comparison of high-dose versus standard-dose radiation therapy, this Phase I/II study was initiated to establish the maximum tolerated dose of radiation therapy in the setting of concurrent chemotherapy, using three-dimensional conformal radiation therapy for non-small-cell lung cancer. Methods and Materials: Eligibility included patients with histologically proven, unresectable Stages I to III non-small-cell lung cancer. Concurrent chemotherapy consisted of paclitaxel, 50 mg/m{sup 2}, and carboplatin, AUC of 2, given weekly. The radiation dose was to be sequentially intensified by increasing the daily fraction size, starting from 75.25 Gy/35 fractions. Results: The Phase I portion of this study accrued 17 patients from 10 institutions and was closed in January 2004. After the initial 8 patients were accrued to cohort 1, the trial closed temporarily on September 26, 2002, due to reported toxicity. Two acute treatment-related dose-limiting toxicities (DLTs) were reported at the time: a case of grade 5 and grade 3 radiation pneumonitis. The protocol, therefore, was revised to de-escalate the radiation therapy dose (74 Gy/37 fractions). Patients in cohort 1 continued to develop toxicity, with 6/8 (75%) patients eventually developing grade >=3 events. Cohort 2 accrued 9 patients. There was one DLT, a grade 3 esophagitis, in cohort 2 in the first 5 patients (1/5 patients) and no DLTs for the next 2 patients (0/2 patients). Conclusions: The maximum tolerated dose was determined to be 74 Gy/37 fractions (2.0 Gy per fraction) using three-dimensional conformal radiation therapy with concurrent paclitaxel and carboplatin therapy. This dose level in the Phase II portion has been well tolerated, with low rates of acute and late lung toxicities.

  17. Dose estimation software for radiation biodosimetry.

    PubMed

    Ainsbury, Elizabeth A; Lloyd, David C

    2010-02-01

    Cytogenetic analysis of chromosome damage in blood lymphocytes is widely used for radiation biodosimetry. Mathematical and statistical analysis is extremely important for accurate assessment of the data and results, and there are a number of classical statistical methods which are routinely employed. However, the large number of different mathematical techniques, the dependence of the models on certain statistical principles, and the complexity of some of the methods can lead to errors in data analysis and thus misinterpretation of results. Cytogenetic dose estimation software has been developed to address these problems by simplifying mathematical and statistical analysis of the cytogenetic data. "Dose Estimate" is a collection of mathematical and statistical methods based on the cytogenetic methods that are used for biodosimetry at the Health Protection Agency and elsewhere in the radiation cytogenetics community. Details of the biological and mathematical tools incorporated into the software are presented. Preliminary testing has been carried out, and the results demonstrate the accuracy and usefulness of the software in its current form. Proposals for improving the software through implementation of recently published Bayesian analysis techniques for cytogenetics are also outlined. An evaluation copy of the software is available on request from the authors.

  18. Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi-centre diagnostic reference level in Queensland public hospitals

    SciTech Connect

    Crowhurst, James A; Whitby, Mark; Thiele, David; Halligan, Toni; Westerink, Adam; Crown, Suzanne; Milne, Jillian

    2014-09-15

    Radiation dose to patients undergoing invasive coronary angiography (ICA) is relatively high. Guidelines suggest that a local benchmark or diagnostic reference level (DRL) be established for these procedures. This study sought to create a DRL for ICA procedures in Queensland public hospitals. Data were collected for all Cardiac Catheter Laboratories in Queensland public hospitals. Data were collected for diagnostic coronary angiography (CA) and single-vessel percutaneous intervention (PCI) procedures. Dose area product (P{sub KA}), skin surface entrance dose (K{sub AR}), fluoroscopy time (FT), and patient height and weight were collected for 3 months. The DRL was set from the 75th percentile of the P{sub KA.} 2590 patients were included in the CA group where the median FT was 3.5 min (inter-quartile range = 2.3–6.1). Median K{sub AR} = 581 mGy (374–876). Median P{sub KA} = 3908 uGym{sup 2} (2489–5865) DRL = 5865 uGym{sup 2}. 947 patients were included in the PCI group where median FT was 11.2 min (7.7–17.4). Median K{sub AR} = 1501 mGy (928–2224). Median P{sub KA} = 8736 uGym{sup 2} (5449–12,900) DRL = 12,900 uGym{sup 2}. This study established a benchmark for radiation dose for diagnostic and interventional coronary angiography in Queensland public facilities.

  19. Radiation measurements and doses at SST altitudes

    NASA Technical Reports Server (NTRS)

    Foelsche, T.

    1972-01-01

    Radiation components and dose equivalents due to galactic and solar cosmic rays in the high atmosphere, especially at SST altitudes, are presented. The dose equivalent rate for the flight personnel flying 500 hours per year in cruise altitudes of 60,000-65,000 feet (18-19.5 km) in high magnetic latitudes is about 0.75-1.0 rem per year averaged over the solar cycle, or about 15-20 percent of the maximum permissible dose rate.

  20. Radiation Dose from Reentrant Electrons

    NASA Technical Reports Server (NTRS)

    Badhwar, G.D.; Cleghorn, T. E.; Watts, J.

    2003-01-01

    In estimating the crew exposures during an EVA, the contribution of reentrant electrons has always been neglected. Although the flux of these electrons is small compared to the flux of trapped electrons, their energy spectrum extends to several GeV compared to about 7 MeV for trapped electrons. This is also true of splash electrons. Using the measured reentrant electron energy spectra, it is shown that the dose contribution of these electrons to the blood forming organs (BFO) is more than 10 times greater than that from the trapped electrons. The calculations also show that the dose-depth response is a very slowly changing function of depth, and thus adding reasonable amounts of additional shielding would not significantly lower the dose to BFO.

  1. Randomized Noninferiority Trial of Reduced High-Dose Volume Versus Standard Volume Radiation Therapy for Muscle-Invasive Bladder Cancer: Results of the BC2001 Trial (CRUK/01/004)

    SciTech Connect

    Huddart, Robert A.; Hall, Emma; Hussain, Syed A.; Jenkins, Peter; Rawlings, Christine; Tremlett, Jean; Crundwell, Malcolm; Adab, Fawzi A.; Sheehan, Denise; Syndikus, Isabel; Hendron, Carey; Lewis, Rebecca; Waters, Rachel; James, Nicholas D.

    2013-10-01

    Purpose: To test whether reducing radiation dose to uninvolved bladder while maintaining dose to the tumor would reduce side effects without impairing local control in the treatment of muscle-invasive bladder cancer. Methods and Materials: In this phase III multicenter trial, 219 patients were randomized to standard whole-bladder radiation therapy (sRT) or reduced high-dose volume radiation therapy (RHDVRT) that aimed to deliver full radiation dose to the tumor and 80% of maximum dose to the uninvolved bladder. Participants were also randomly assigned to receive radiation therapy alone or radiation therapy plus chemotherapy in a partial 2 × 2 factorial design. The primary endpoints for the radiation therapy volume comparison were late toxicity and time to locoregional recurrence (with a noninferiority margin of 10% at 2 years). Results: Overall incidence of late toxicity was less than predicted, with a cumulative 2-year Radiation Therapy Oncology Group grade 3/4 toxicity rate of 13% (95% confidence interval 8%, 20%) and no statistically significant differences between groups. The difference in 2-year locoregional recurrence free rate (RHDVRT − sRT) was 6.4% (95% confidence interval −7.3%, 16.8%) under an intention to treat analysis and 2.6% (−12.8%, 14.6%) in the “per-protocol” population. Conclusions: In this study RHDVRT did not result in a statistically significant reduction in late side effects compared with sRT, and noninferiority of locoregional control could not be concluded formally. However, overall low rates of clinically significant toxicity combined with low rates of invasive bladder cancer relapse confirm that (chemo)radiation therapy is a valid option for the treatment of muscle-invasive bladder cancer.

  2. Automated extraction of radiation dose information for CT examinations.

    PubMed

    Cook, Tessa S; Zimmerman, Stefan; Maidment, Andrew D A; Kim, Woojin; Boonn, William W

    2010-11-01

    Exposure to radiation as a result of medical imaging is currently in the spotlight, receiving attention from Congress as well as the lay press. Although scanner manufacturers are moving toward including effective dose information in the Digital Imaging and Communications in Medicine headers of imaging studies, there is a vast repository of retrospective CT data at every imaging center that stores dose information in an image-based dose sheet. As such, it is difficult for imaging centers to participate in the ACR's Dose Index Registry. The authors have designed an automated extraction system to query their PACS archive and parse CT examinations to extract the dose information stored in each dose sheet. First, an open-source optical character recognition program processes each dose sheet and converts the information to American Standard Code for Information Interchange (ASCII) text. Each text file is parsed, and radiation dose information is extracted and stored in a database which can be queried using an existing pathology and radiology enterprise search tool. Using this automated extraction pipeline, it is possible to perform dose analysis on the >800,000 CT examinations in the PACS archive and generate dose reports for all of these patients. It is also possible to more effectively educate technologists, radiologists, and referring physicians about exposure to radiation from CT by generating report cards for interpreted and performed studies. The automated extraction pipeline enables compliance with the ACR's reporting guidelines and greater awareness of radiation dose to patients, thus resulting in improved patient care and management.

  3. Low-dose radiation: a cause of breast cancer

    SciTech Connect

    Land, C.E.

    1980-08-15

    It is likely that the breast is the organ most sensitive to radiation carcinogenesis in postpubertal women. Studies of different exposed populations have yielded remarkably consistent results, in spite of wide differences in underlying breast cancer rates and conditions of exposure. Excess risk is approximately proportional to dose, and is relatively independent of ionization density and fractionization of dose. This implies that the risk associated with low-dose exposures to ionizing radiation can be estimated with some confidence from higher-dose data. Excess risk is heavily dependent on age at exposure but relatively independent of population differences in normal risk. The temporal patterns after exposure of both radiation-induced and naturally occurring breast cancer are similar, suggesting a strong influence of factors other than radiation on radiation-induced breast cancer. Uncertainties remain about risks from exposures before puberty and after menopause.

  4. A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results.

    PubMed

    Doran, S J; Koerkamp, K K; Bero, M A; Jenneson, P; Morton, E J; Gilboy, W B

    2001-12-01

    Methods based on magnetic resonance imaging for the measurement of three-dimensional distributions of radiation dose are highly developed. However, relatively little work has been done on optical computed tomography (OCT). This paper describes a new OCT scanner based on a broad beam light source and a two-dimensional charge-coupled device (CCD) detector. A number of key design features are discussed including the light source; the scanning tank, turntable and stepper motor control; the diffuser screen onto which images are projected and the detector. It is shown that the non-uniform pixel sensitivity of the low-cost CCD detector used and the granularity of the diffuser screen lead to a serious ring artefact in the reconstructed images. Methods are described for eliminating this. The problems arising from reflection and refraction at the walls of the gel container are explained. Optical ray-tracing simulations are presented for cylindrical containers with a variety of radii and verified experimentally. Small changes in the model parameters lead to large variations in the signal intensity observed in the projection data. The effect of imperfect containers on data quality is discussed and a method based on a 'correction scan' is shown to be successful in correcting many of the related image artefacts. The results of two tomography experiments are presented. In the first experiment, a radiochromic Fricke gel sample was exposed four times in different positions to a 100 kVp x-ray beam perpendicular to the plane of imaging. Images of absorbed dose with slice thickness of 140 microm were acquired. with 'true' in-plane resolution of 560 x 560 microm2 at the edge of the 72 mm field of view and correspondingly higher resolution at the centre. The nominal doses measured correlated well with the known exposure times. The second experiment demonstrated the well known phenomenon of diffusion in the dosemeter gels and yielded a value of (0.12 +/- 0.02) mm2 s(-1) for the diffusion

  5. Radiation dose from cigarette tobacco

    SciTech Connect

    Papastefanou, C.

    2008-08-07

    The radioactivity in tobacco leaves collected from 15 different regions of Greece before cigarette production was studied in order to estimate the effective dose from cigarette tobacco due to the naturally occurring primordial radionuclides, such as {sup 226}Ra and {sup 210}Pb of the uranium series and {sup 228}Ra of the thorium series and/or man-made produced radionuclides, such as {sup 137}Cs of Chernobyl origin. Gamma-ray spectrometry was applied using Ge planar and coaxial type detectors of high resolution and high efficiency. It was concluded that the annual effective dose due to inhalation for adults (smokers) for {sup 226}Ra varied from 42.5 to 178.6 {mu}Sv y{sup -1} (average 79.7 {mu}Sv y{sup -1}), while for {sup 228}Ra from 19.3 to 116.0 {mu}Sv y{sup -1} (average 67.1 {mu}Sv y{sup -1}) and for {sup 210}Pb from 47.0 to 134.9 {mu}Sv y{sup -1} (average 104.7 {mu}Sv y{sup -1}), that is the same order of magnitude for each radionuclide. The sum of the effective dose of the three natural radionuclides varied from 151.9 to 401.3 {mu}Sv y{sup -1} (average 251.5 {mu}Sv y{sup -1}). The annual effective dose from {sup 137}Cs of Chernobyl origin was three orders of magnitude lower as it varied from 70.4 to 410.4 nSv y{sup -1} (average 199.3 nSv y{sup -1})

  6. Radiation Dose from Cigarette Tobacco

    NASA Astrophysics Data System (ADS)

    Papastefanou, C.

    2008-08-01

    The radioactivity in tobacco leaves collected from 15 different regions of Greece before cigarette production was studied in order to estimate the effective dose from cigarette tobacco due to the naturally occurring primordial radionuclides, such as 226Ra and 210Pb of the uranium series and 228Ra of the thorium series and/or man-made produced radionuclides, such as 137Cs of Chernobyl origin. Gamma-ray spectrometry was applied using Ge planar and coaxial type detectors of high resolution and high efficiency. It was concluded that the annual effective dose due to inhalation for adults (smokers) for 226Ra varied from 42.5 to 178.6 μSv y-1 (average 79.7 μSv y-1), while for 228Ra from 19.3 to 116.0 μSv y-1 (average 67.1 μSv y-1) and for 210Pb from 47.0 to 134.9 μSv y-1 (average 104.7 μSv y-1), that is the same order of magnitude for each radionuclide. The sum of the effective dose of the three natural radionuclides varied from 151.9 to 401.3 μSv y-1 (average 251.5 μSv y-1). The annual effective dose from 137Cs of Chernobyl origin was three orders of magnitude lower as it varied from 70.4 to 410.4 nSv y-1 (average 199.3 nSv y-1).

  7. Commentary 2 to Cox and Little: radiation-induced oncogenic transformation: the interplay between dose, dose protraction, and radiation quality

    NASA Technical Reports Server (NTRS)

    Brenner, D. J.; Hall, E. J.

    1992-01-01

    There is now a substantial body of evidence for end points such as oncogenic transformation in vitro, and carcinogenesis and life shortening in vivo, suggesting that dose protraction leads to an increase in effectiveness relative to a single, acute exposure--at least for radiations of medium linear energy transfer (LET) such as neutrons. Table I contains a summary of the pertinent data from studies in which the effect is seen. [table: see text] This phenomenon has come to be known as the "inverse dose rate effect," because it is in marked contrast to the situation at low LET, where protraction in delivery of a dose of radiation, either by fractionation or low dose rate, results in a decreased biological effect; additionally, at medium and high LET, for radiobiological end points such as clonogenic survival, the biological effectiveness is independent of protraction. The quantity and quality of the published reports on the "inverse dose rate effect" leaves little doubt that the effect is real, but the available evidence indicates that the magnitude of the effect is due to a complex interplay between dose, dose rate, and radiation quality. Here, we first summarize the available data on the inverse dose rate effect and suggest that it follows a consistent pattern in regard to dose, dose rate, and radiation quality; second, we describe a model that predicts these features; and, finally, we describe the significance of the effect for radiation protection.

  8. Commentary 2 to Cox and Little: radiation-induced oncogenic transformation: the interplay between dose, dose protraction, and radiation quality

    NASA Technical Reports Server (NTRS)

    Brenner, D. J.; Hall, E. J.

    1992-01-01

    There is now a substantial body of evidence for end points such as oncogenic transformation in vitro, and carcinogenesis and life shortening in vivo, suggesting that dose protraction leads to an increase in effectiveness relative to a single, acute exposure--at least for radiations of medium linear energy transfer (LET) such as neutrons. Table I contains a summary of the pertinent data from studies in which the effect is seen. [table: see text] This phenomenon has come to be known as the "inverse dose rate effect," because it is in marked contrast to the situation at low LET, where protraction in delivery of a dose of radiation, either by fractionation or low dose rate, results in a decreased biological effect; additionally, at medium and high LET, for radiobiological end points such as clonogenic survival, the biological effectiveness is independent of protraction. The quantity and quality of the published reports on the "inverse dose rate effect" leaves little doubt that the effect is real, but the available evidence indicates that the magnitude of the effect is due to a complex interplay between dose, dose rate, and radiation quality. Here, we first summarize the available data on the inverse dose rate effect and suggest that it follows a consistent pattern in regard to dose, dose rate, and radiation quality; second, we describe a model that predicts these features; and, finally, we describe the significance of the effect for radiation protection.

  9. Wide-range radiation dose monitor

    DOEpatents

    Kopp, M.K.

    1984-09-20

    A radiation dose-rate monitor is provided which operates in a conventional linear mode for radiation in the 0 to 0.5 R/h range and utilizes a nonlinear mode of operation for sensing radiation from 0.5 R/h to over 500 R/h. The nonlinear mode is achieved by a feedback circuit which adjusts the high voltage bias of the proportional counter, and hence its gas gain, in accordance with the amount of radiation being monitored. This allows compression of readout onto a single scale over the range of 0 to greater than 500 R/h without scale switching operations.

  10. Wide-range radiation dose monitor

    DOEpatents

    Kopp, Manfred K.

    1986-01-01

    A radiation dose-rate monitor is provided which operates in a conventional linear mode for radiation in the 0 to 0.5 R/h range and utilizes a nonlinear mode of operation for sensing radiation from 0.5 R/h to over 500 R/h. The nonlinear mode is achieved by a feedback circuit which adjusts the high voltage bias of the proportional counter, and hence its gas gain, in accordance with the amount of radiation being monitored. This allows compression of readout onto a single scale over the range of 0 to greater than 500 R/h without scale switching operations.

  11. A Biodosimeter for Multiparametric Determination of Radiation Dose, Radiation Quality, and Radiation Risk

    NASA Technical Reports Server (NTRS)

    Richmond, Robert; Cruz, Angela; Jansen, Heather; Bors, Karen

    2003-01-01

    the quality of the radiation dose absorbed by individual cells. The principal value of this reported potential multiparametric cellular biodosimeter is suggested to be that it justifies a search for similar but more robust radiogenic assays. That is, K18 is only one radiation dose-sensitive expressed protein, whereas analytical techniques of genomics and proteomics can be used to simultaneously analyze multiple gene and protein expressions resulting from radiation-dose absorption. The potential usefulness of multiparametric cellular biodosimeters will be best realized from quantitatively profiling these multiple markers using these modern techniques.

  12. A Biodosimeter for Multiparametric Determination of Radiation Dose, Radiation Quality, and Radiation Risk

    NASA Technical Reports Server (NTRS)

    Richmond, Robert; Cruz, Angela; Jansen, Heather; Bors, Karen

    2003-01-01

    the quality of the radiation dose absorbed by individual cells. The principal value of this reported potential multiparametric cellular biodosimeter is suggested to be that it justifies a search for similar but more robust radiogenic assays. That is, K18 is only one radiation dose-sensitive expressed protein, whereas analytical techniques of genomics and proteomics can be used to simultaneously analyze multiple gene and protein expressions resulting from radiation-dose absorption. The potential usefulness of multiparametric cellular biodosimeters will be best realized from quantitatively profiling these multiple markers using these modern techniques.

  13. Results of radiation treatment of cerebellar medulloblastoma

    SciTech Connect

    Chin, H.W.; Maruyama, Y.

    1981-06-01

    A review of 20 patients with medulloblastoma who were treated with radiation treatment at the University of Kentucky Medical Center is presented. The age range was 1.5 to 31 years; only five patients were older than 16 years of age. A relationship between radiation dose and survival was obtained. A 5-year disease-free survival of 80% was obtained with a radiation dose of 5000 rad and more whereas only 15% of patients survived five years with a radiation dose of less than 5000. Treatment failures were mainly a result of local recurrence. This occurred in 78% of patients who were treated with radiation dosage of less than 5000 rad. The development of hydrocephalus appeared to be because of advanced disease and no 5-year survivors were noted in five patients who underwent systemic shunting procedure. A review of published data also supports a dose-dependent 5-year survival. Effective radiation treatment methods, along with doses to 5000 to 5500 rad, appear to lead to long term survival, frequent tumor cure and high performance outcome.

  14. Nuclear cardiology practice and associated radiation doses in Europe: results of the IAEA Nuclear Cardiology Protocols Study (INCAPS) for the 27 European countries.

    PubMed

    Lindner, Oliver; Pascual, Thomas N B; Mercuri, Mathew; Acampa, Wanda; Burchert, Wolfgang; Flotats, Albert; Kaufmann, Philipp A; Kitsiou, Anastasia; Knuuti, Juhani; Underwood, S Richard; Vitola, João V; Mahmarian, John J; Karthikeyan, Ganesan; Better, Nathan; Rehani, Madan M; Kashyap, Ravi; Dondi, Maurizio; Paez, Diana; Einstein, Andrew J

    2016-04-01

    Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 - 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the

  15. Radiation dose measurement for various parameters in MDCT

    NASA Astrophysics Data System (ADS)

    Lee, Chang-Lae; Kim, Hee-Joung; Jeon, Seong Su; Cho, Hyo-Min; Nam, So Ra; Jung, Ji-Young

    2008-03-01

    The MDCT parameters affecting radiation dose include tube voltage, tube current, change of beam collimation, and size of the human body. The purpose of this study was to measure and evaluate radiation dose for MDCT parameters. A comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber was performed. The ionization chamber was used for measuring radiation dose in the MDCT, as well as of CTDI W according to temperature and pressure correction factors in the CT room. As a result, the patient dose of CTDI W values linearly increased as tube voltage and current were increased, and nonlinearly decreased as beam collimation was increased. And the CTDI W value which was reflected calibration factors, as well as correction factors of temperature and pressure, was found to be greater by the range of 0.479 ~ 3.162 mGy in effective radiation dose than the uncorrected value. Also, Under the abdomen routine CT conditions used in hospitals, patient exposure dose showed a difference of a maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the application of temperature and pressure of the CT room are crucial in measuring and calculating patient exposure dose.

  16. Imaging of Radiation Dose for Stereotactic Radiosurgery

    SciTech Connect

    Guan, Timothy Y.; Almond, Peter R.; Park, Hwan C.; Lindberg, Robert D.; Shields, Christopher B.

    2015-01-15

    The distributions of radiation dose for stereotactic radiosurgery, using a modified linear accelerator (Philips SL-25 and SRS-200), have been studied by using three different dosimeters: (1) ferrous-agarose-xylenol orange (FAX) gels, (2) TLD, and (3) thick-emulsion GafChromic dye film. These dosimeters were loaded into a small volume of defect in a phantom head. A regular linac stereotactic radiosurgery treatment was then given to the phantom head for each type of dosimeter. The measured radiation dose and its distributions were found to be in good agreement with those calculated by the treatment planning computer.

  17. Radiation dose in temporomandibular joint zonography

    SciTech Connect

    Coucke, M.E.; Bourgoignie, R.R.; Dermaut, L.R.; Bourgoignie, K.A.; Jacobs, R.J. )

    1991-06-01

    Temporomandibular joint morphology and function can be evaluated by panoramic zonography. Thermoluminescent dosimetry was applied to evaluate the radiation dose to predetermined sites on a phantom eye, thyroid, pituitary, and parotid, and the dose distribution on the skin of the head and neck when the TMJ program of the Zonarc panoramic x-ray unit was used. Findings are discussed with reference to similar radiographic techniques.

  18. Estimation of the fluence of high-energy electron bursts produced by thunderclouds and the resulting radiation doses received in aircraft

    NASA Astrophysics Data System (ADS)

    Dwyer, J. R.; Smith, D. M.; Uman, M. A.; Saleh, Z.; Grefenstette, B.; Hazelton, B.; Rassoul, H. K.

    2010-05-01

    Using recent X-ray and gamma-ray observations of terrestrial gamma-ray flashes (TGFs) from spacecraft and of natural and rocket-triggered lightning from the ground, along with detailed models of energetic particle transport, we calculate the fluence (integrated flux) of high-energy (million electronvolt) electrons, X rays, and gamma rays likely to be produced inside or near thunderclouds in high electric field regions. We find that the X-ray/gamma-ray fluence predicted for lightning leaders propagating inside thunderclouds agrees well with the fluence calculated for TGFs, suggesting a possible link between these two phenomena. Furthermore, based on reasonable meteorological assumptions about the magnitude and extent of the electric fields, we estimate that the fluence of high-energy runaway electrons can reach biologically significant levels at aircraft altitudes. If an aircraft happened to be in or near the high-field region when either a lightning discharge or a TGF event is occurring, then the radiation dose received by passengers and crew members inside that aircraft could potentially approach 0.1 Sv (10 rem) in less than 1 ms. Considering that commercial aircraft are struck by lightning, on average, one to two times per year, the risk of such large radiation doses should be investigated further.

  19. Principles of CT: radiation dose and image quality.

    PubMed

    Goldman, Lee W

    2007-12-01

    This article discusses CT radiation dose, the measurement of CT dose, and CT image quality. The most commonly used dose descriptor is CT dose index, which represents the dose to a location (e.g., depth) in a scanned volume from a complete series of slices. A weighted average of the CT dose index measured at the center and periphery of dose phantoms provides a convenient single-number estimate of patient dose for a procedure, and this value (or a related indicator that includes the scanned length) is often displayed on the operator's console. CT image quality, as in most imaging, is described in terms of contrast, spatial resolution, image noise, and artifacts. A strength of CT is its ability to visualize structures of low contrast in a subject, a task that is limited primarily by noise and is therefore closely associated with radiation dose: The higher the dose contributing to the image, the less apparent is image noise and the easier it is to perceive low-contrast structures. Spatial resolution is ultimately limited by sampling, but both image noise and resolution are strongly affected by the reconstruction filter. As a result, diagnostically acceptable image quality at acceptable doses of radiation requires appropriately designed clinical protocols, including appropriate kilovolt peaks, amperages, slice thicknesses, and reconstruction filters.

  20. KERMA-based radiation dose management system for real-time patient dose measurement

    NASA Astrophysics Data System (ADS)

    Kim, Kyo-Tae; Heo, Ye-Ji; Oh, Kyung-Min; Nam, Sang-Hee; Kang, Sang-Sik; Park, Ji-Koon; Song, Yong-Keun; Park, Sung-Kwang

    2016-07-01

    Because systems that reduce radiation exposure during diagnostic procedures must be developed, significant time and financial resources have been invested in constructing radiation dose management systems. In the present study, the characteristics of an existing ionization-based system were compared to those of a system based on the kinetic energy released per unit mass (KERMA). Furthermore, the feasibility of using the KERMA-based system for patient radiation dose management was verified. The ionization-based system corrected the effects resulting from radiation parameter perturbations in general radiography whereas the KERMA-based system did not. Because of this difference, the KERMA-based radiation dose management system might overestimate the patient's radiation dose due to changes in the radiation conditions. Therefore, if a correction factor describing the correlation between the systems is applied to resolve this issue, then a radiation dose management system can be developed that will enable real-time measurement of the patient's radiation exposure and acquisition of diagnostic images.

  1. Assessment of the effective dose equivalent for external photon radiation

    SciTech Connect

    Reece, W.D.; Poston, J.W.; Xu, X.G. )

    1993-02-01

    Beginning in January 1994, US nuclear power plants must change the way that they determine the radiation exposure to their workforce. At that time, revisions to Title 10 Part 20 of the Code of Federal Regulations will be in force requiring licensees to evaluate worker radiation exposure using a risk-based methodology termed the effective dose equivalent.'' A research project was undertaken to improve upon the conservative method presently used for assessing effective dose equivalent. In this project effective dose equivalent was calculated using a mathematical model of the human body, and tracking photon interactions for a wide variety of radiation source geometries using Monte Carlo computer code simulations. Algorithms were then developed to relate measurements of the photon flux on the surface of the body (as measured by dosimeters) to effective dose equivalent. This report (Volume I of a two-part study) describes: the concept of effective dose equivalent, the evolution of the concept and its incorporation into regulations, the variations in human organ susceptibility to radiation, the mathematical modeling and calculational techniques used, the results of effective dose equivalent calculations for a broad range of photon energiesand radiation source geometries. The study determined that for beam radiation sources the highest effective dose equivalent occurs for beams striking the front of the torso. Beams striking the rear of the torsoproduce the next highest effective dose equivalent, with effective dose equivalent falling significantly as one departs from these two orientations. For point sources, the highest effective dose equivalent occurs when the sources are in contact with the body on the front of the torso. For females the highest effective dose equivalent occurs when the source is on the sternum, for males when it is on the gonads.

  2. Methods of calculating radiation absorbed dose.

    PubMed

    Wegst, A V

    1987-01-01

    The new tumoricidal radioactive agents being developed will require a careful estimate of radiation absorbed tumor and critical organ dose for each patient. Clinical methods will need to be developed using standard imaging or counting instruments to determine cumulated organ activities with tracer amounts before the therapeutic administration of the material. Standard MIRD dosimetry methods can then be applied.

  3. Low-dose radiation and leukemia

    SciTech Connect

    Linos, A.; Gray, J.E.; Orvis, A.L.; Kyle, R.A.; O'Fallon, W.M.; Kurland, L.T.

    1980-05-15

    We investigated the effect of diagnostic and low-level therapeutic radiation (less than 300 rads to bone marrow) on the development of leukemia. During this study, 138 patients with leukemia (representing all known incidence cases of leukemia in residents of Olmsted County, Minnesota, between 1955 and 1974) were each matched with two controls, and the lifelong experiences of both groups with regard to diagnostic and therapeutic radiation were ascertained. No statistically significant increase was found in the risk of developing leukemia after radiation doses of 0 to 300 rads (3 Gy) to the bone marrow when these amounts were administered in small doses over long periods of time, as in routine medical care.

  4. 10 CFR 20.1004 - Units of radiation dose.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Units of radiation dose. 20.1004 Section 20.1004 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION General Provisions § 20.1004 Units of radiation dose. (a) Definitions. As used in this part, the units of radiation dose are:...

  5. 10 CFR 20.1004 - Units of radiation dose.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Units of radiation dose. 20.1004 Section 20.1004 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION General Provisions § 20.1004 Units of radiation dose. (a) Definitions. As used in this part, the units of radiation dose are:...

  6. 10 CFR 20.1004 - Units of radiation dose.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Units of radiation dose. 20.1004 Section 20.1004 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION General Provisions § 20.1004 Units of radiation dose. (a) Definitions. As used in this part, the units of radiation dose are: Gray...

  7. 10 CFR 20.1004 - Units of radiation dose.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Units of radiation dose. 20.1004 Section 20.1004 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION General Provisions § 20.1004 Units of radiation dose. (a) Definitions. As used in this part, the units of radiation dose are: Gray...

  8. 10 CFR 20.1004 - Units of radiation dose.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Units of radiation dose. 20.1004 Section 20.1004 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION General Provisions § 20.1004 Units of radiation dose. (a) Definitions. As used in this part, the units of radiation dose are: Gray...

  9. Radiation dose reduction in the invasive cardiovascular laboratory: implementing a culture and philosophy of radiation safety.

    PubMed

    Fetterly, Kenneth A; Mathew, Verghese; Lennon, Ryan; Bell, Malcolm R; Holmes, David R; Rihal, Charanjit S

    2012-08-01

    This paper investigates the effects of sustained practice and x-ray system technical changes on the radiation dose administered to adult patients during invasive cardiovascular procedures. It is desirable to reduce radiation dose associated with medical imaging to minimize the risk of adverse radiation effects to both patients and staff. Several clinical practice and technical changes to elevate radiation awareness and reduce patient radiation dose were implemented under the guidance of a cardiovascular invasive labs radiation safety committee. Practice changes included: intraprocedure radiation dose announcements; reporting of procedures for which the air-kerma exceeded 6,000 mGy, including procedure air-kerma in the clinical report; and establishing compulsory radiation safety training for fellows. Technical changes included establishing standard x-ray imaging protocols, increased use of x-ray beam spectral filters, reducing the detector target dose for fluoroscopy and acquisition imaging, and reducing the fluoroscopy frame rate to 7.5 s(-1). Patient- and procedure-specific cumulative skin dose was calculated from air-kerma values and evaluated retrospectively over a period of 3 years. Data were categorized to include all procedures, percutaneous coronary interventions, coronary angiography, noncardiac vascular angiography and interventions, and interventions to treat structural heart disease. Statistical analysis was based on a comparison of the cumulative skin dose for procedures performed during the first and last quarters of the 3-year study period. A total of 18,115 procedures were performed by 27 staff cardiologists and 65 fellows-in-training. Considering all procedures, the mean cumulative skin dose decreased from 969 to 568 mGy (40% reduction) over 3 years. This work demonstrates that a philosophy of radiation safety, implemented through a collection of sustained practice and x-ray system changes, can result in a significant decrease in the radiation dose

  10. [Forecast of collective radiation dose decrease of the population of Belarus as the result of optimization of moveable potassium contents in soils contaminated by 137Cs].

    PubMed

    Putiatin, Iu V; Adianova, O B

    2010-01-01

    Results of study on an efficiency of potassium moveable content for decrease of a collective dose from 137Cs to the population of Belarus are presented. On the basis of the "cost-benefit" analysis it is shown, that expenses for decreasing averted collective dose due to increase of potassium contents on arable lands amounts to more than 80 thousand US dollars per 1 man.-Sv depending on density of soil contamination of rural districts by 137Cs. It is found that high effect (costs less than 40 thousand US dollars per 1 man.-Sv on hectare of arable land) on averted collective dose from 137Cs at cultivation of cereals can be expected at an optimization of mobile potassium contents in sod-podzolic loamy sand soils with density of 137Cs contamination more than 925 kBq/m2, sand soils--more than 1184, light loam soils--more than 629 kBq/m2.

  11. Agriculture-related radiation dose calculations

    SciTech Connect

    Furr, J.M.; Mayberry, J.J.; Waite, D.A.

    1987-10-01

    Estimates of radiation dose to the public must be made at each stage in the identification and qualification process leading to siting a high-level nuclear waste repository. Specifically considering the ingestion pathway, this paper examines questions of reliability and adequacy of dose calculations in relation to five stages of data availability (geologic province, region, area, location, and mass balance) and three methods of calculation (population, population/food production, and food production driven). Calculations were done using the model PABLM with data for the Permian and Palo Duro Basins and the Deaf Smith County area. Extra effort expended in gathering agricultural data at succeeding environmental characterization levels does not appear justified, since dose estimates do not differ greatly; that effort would be better spent determining usage of food types that contribute most to the total dose; and that consumption rate and the air dispersion factor are critical to assessment of radiation dose via the ingestion pathway. 17 refs., 9 figs., 32 tabs.

  12. Strategies for reducing radiation dose in CT.

    PubMed

    McCollough, Cynthia H; Primak, Andrew N; Braun, Natalie; Kofler, James; Yu, Lifeng; Christner, Jodie

    2009-01-01

    In recent years, the media has focused on the potential danger of radiation exposure from CT, even though the potential benefit of a medically indicated CT far outweighs the potential risks. This attention has reminded the radiology community that doses must be as low as reasonably achievable (ALARA) while maintaining diagnostic image quality. To satisfy the ALARA principle, the dose reduction strategies described in this article must be well understood and properly used. The use of CT must also be justified for the specific diagnostic task.

  13. Peripheral Doses from Noncoplanar IMRT for Pediatric Radiation Therapy

    SciTech Connect

    Kan, Monica W.K.; Leung, Lucullus H.T.; Kwong, Dora L.W.; Wong, Wicger; Lam, Nelson

    2010-01-01

    The use of noncoplanar intensity-modulated radiation therapy (IMRT) might result in better sparing of some critical organs because of a higher degree of freedom in beam angle optimization. However, this can lead to a potential increase in peripheral dose compared with coplanar IMRT. The peripheral dose from noncoplanar IMRT has not been previously quantified. This study examines the peripheral dose from noncoplanar IMRT compared with coplanar IMRT for pediatric radiation therapy. Five cases with different pediatric malignancies in head and neck were planned with both coplanar and noncoplanar IMRT techniques. The plans were performed such that the tumor coverage, conformality, and dose uniformity were comparable for both techniques. To measure the peripheral doses of the 2 techniques, thermoluminescent dosimeters (TLD) were placed in 10 different organs of a 5-year-old pediatric anthropomorphic phantom. With the use of noncoplanar beams, the peripheral doses to the spinal cord, bone marrow, lung, and breast were found to be 1.8-2.5 times of those using the coplanar technique. This is mainly because of the additional internal scatter dose from the noncoplanar beams. Although the use of noncoplanar technique can result in better sparing of certain organs such as the optic nerves, lens, or inner ears depending on how the beam angles were optimized on each patient, oncologists should be alert of the possibility of significantly increasing the peripheral doses to certain radiation-sensitive organs such as bone marrow and breast. This might increase the secondary cancer risk to patients at young age.

  14. Space radiation absorbed dose distribution in a human phantom

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Atwell, W.; Badavi, F. F.; Yang, T. C.; Cleghorn, T. F.

    2002-01-01

    The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose

  15. Space radiation absorbed dose distribution in a human phantom

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Atwell, W.; Badavi, F. F.; Yang, T. C.; Cleghorn, T. F.

    2002-01-01

    The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose

  16. Space radiation absorbed dose distribution in a human phantom.

    PubMed

    Badhwar, G D; Atwell, W; Badavi, F F; Yang, T C; Cleghorn, T F

    2002-01-01

    The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose

  17. A Phase I/II Radiation Dose Escalation Study with Concurrent Chemotherapy for Patients with Inoperable Stages I-III Non-Small Cell Lung Cancer: The Phase I Results of RTOG 0117

    PubMed Central

    Bradley, Jeffrey D.; Moughan, Jennifer; Graham, Mary V.; Byhardt, Roger; Govindan, Ramaswamy; Fowler, Jack; Purdy, James A.; Michalski, Jeff M; Gore, Elizabeth; Choy, Hak

    2009-01-01

    Background In preparation for a Phase III comparison of high-dose versus standard dose radiation therapy, this Phase I/II study was initiated to establish the maximum tolerated dose (MTD) of radiation therapy, in the setting of concurrent chemotherapy, using 3DCRT for NSCLC. Methods Eligibility included patients with histologically proven, unresectable Stages I-III NSCLC. Concurrent chemotherapy consisted of paclitaxel 50 mg/m2 and carboplatin AUC=2 given weekly. Radiation dose was to be sequentially intensified by increasing the daily fraction size starting from 75.25 Gy/35 fractions. Results The Phase I portion of this study accrued 17 patients from 10 institutions and was closed in January 2004. After the initial eight patients were accrued to Cohort 1, the trial closed temporarily on September 26, 2002 due to reported toxicity. Two acute treatment-related DLTs were reported at the time: a grade 5 and a grade 3 radiation pneumonitis. The protocol, therefore, was revised to de-escalate the RT dose (74 Gy/37 fractions). Patients in Cohort 1 continued to develop toxicity with 6/8 (75%) eventually developing ≥ grade 3 events. Cohort 2 accrued 9 patients. There was one DLT, a grade 3 esophagitis, in Cohort 2 in the first 5 patients (1/5) and no DLTs for the next 2 patients (0/2). Conclusions The MTD was determined to be 74 Gy/37 fractions (2.0 Gy per fraction) using 3DCRT with concurrent paclitaxel and carboplatin. This dose level, in the Phase II portion, has been well tolerated with low rates of acute and late lung toxicities. PMID:20457350

  18. Low-Dose Radiation Cataract and Genetic Determinants of Radiosensitivity

    SciTech Connect

    Kleiman, Norman Jay

    2013-11-30

    The lens of the eye is one of the most radiosensitive tissues in the body. Ocular ionizing radiation exposure results in characteristic, dose related, progressive lens changes leading to cataract formation. While initial, early stages of lens opacification may not cause visual disability, the severity of such changes progressively increases with dose until vision is impaired and cataract extraction surgery may be required. Because of the transparency of the eye, radiation induced lens changes can easily be followed non-invasively over time. Thus, the lens provides a unique model system in which to study the effects of low dose ionizing radiation exposure in a complex, highly organized tissue. Despite this observation, considerable uncertainties remain surrounding the relationship between dose and risk of developing radiation cataract. For example, a growing number of human epidemiological findings suggest significant risk among various groups of occupationally and accidentally exposed individuals and confidence intervals that include zero dose. Nevertheless, questions remain concerning the relationship between lens opacities, visual disability, clinical cataract, threshold dose and/or the role of genetics in determining radiosensitivity. Experimentally, the response of the rodent eye to radiation is quite similar to that in humans and thus animal studies are well suited to examine the relationship between radiation exposure, genetic determinants of radiosensitivity and cataractogenesis. The current work has expanded our knowledge of the low-dose effects of X-irradiation or high-LET heavy ion exposure on timing and progression of radiation cataract and has provided new information on the genetic, molecular, biochemical and cell biological features which contribute to this pathology. Furthermore, findings have indicated that single and/or multiple haploinsufficiency for various genes involved in DNA repair and cell cycle checkpoint control, such as Atm, Brca1 or Rad9

  19. Optical fibres for high radiation dose environments

    NASA Astrophysics Data System (ADS)

    Henschel, H.; Kohn, O.; Schmidt, H. U.; Bawirzanski, E.; Landers, A.

    1994-06-01

    A variety of modern single mode (SM) and graded index (GI) fibres as well as a new pure silica multimode step index (MMSI) fibre with high OH content were irradiated at a Co-60 gamma ray source with a dose rate of approximately = 1.5Gy/s up to a total dose of 10(exp 6)Gy. The radiation-induced loss of all fibres was measured continuously during and after irradiation at discrete wavelengths (approximately = 850, approximately = 1070, approximately = 1300, approximately = 1550nm). With one SM fibre type also the 'breaking stress' before and after irradiation was determined. Radiation-induced losses of approximately less than 5dB/50m (at approximately = 1300nm) were found with some of the SM fibres, whereas the MMSI fibre showed a final induced loss of only 0.5dB/50m at 1070nm wavelength. The breaking stress of the SM fibre increased by about 10%.

  20. Effects of low doses of radiation.

    PubMed

    Fry, R J

    1996-06-01

    This is a brief review of what is known from experimental studies about the effects of low doses of radiation, and approaches that might improve risk estimates are discussed. The dose-response relationships for cancer induction by radiation vary markedly between tissues. The evidence suggests that 1) the induction of the initial events is dependent on the cell type because the size and/or the number of targets and how the cells handle the initial lesions differs between cell types; and 2) there are marked differences among tissues how initial lesions are expressed and proceed to overt cancer. The recent findings about adaptive responses are discussed in the context of what they contribute to our understanding about the response to irradiation. Lastly, the possibility of extending the approach of determining "The probability of causation," which Vic Bond played such an important role in establishing, is raised.

  1. SU-E-J-08: Comparison of Unintended Radiation Doses to Organs at Risk Resulting From the Out-Of-Field Therapeutic Beams and From Image-Guidance X-Ray Procedures

    SciTech Connect

    Ding, G; Wang, L

    2015-06-15

    Purpose: The unintended radiation dose to organs at risk (OAR) can be contributed from imaging guidance procedures as well as from leakage and scatter of therapeutic beams. This study compares the imaging dose with the unintended out-of-field therapeutic dose to patient sensitive organs. Methods: The Monte Carlo EGSnrc user codes, BEAMnrc and DOSXYZnrc, were used to simulate kV X-ray sources from imaging devices as well as the therapeutic IMRT/VMAT beams and to calculate doses to target and OARs on patient treatment planning CT images. The accuracy of the Monte Carlo simulations was benchmarked against measurements in phantoms. The dose-volume histogram was utilized in analyzing the patient organ doses. Results: The dose resulting from Standard Head kV-CBCT scans to bone and soft tissues ranges from 0.7 to 1.1 cGy and from 0.03 to 0.3 cGy, respectively. The dose resulting from Thorax scans on the chest to bone and soft tissues ranges from 1.1 to 1.8 cGy and from 0.3 to 0.6 cGy, respectively. The dose resulting from Pelvis scans on the abdomen to bone and soft tissues range from 3.2 to 4.2 cGy and from 1.2 to 2.2 cGy, respectively. The out-of-field doses to OAR are sensitive to the distance between the treated target and the OAR. For a typical Head-and-Neck IMRT/VMAT treatment the out-of-field doses to eyes are 1–3% of the target dose, or 2–6 cGy per fraction. Conclusion: The imaging doses to OAR are predictable based on the imaging protocols used when OARs are within the imaged volume and can be estimated and accounted for by using tabulated values. The unintended out-of-field doses are proportional to the target dose, strongly depend on the distance between the treated target and OAR, and are generally higher comparing to the imaging dose. This work was partially supported by Varian research grant VUMC40590.

  2. Radiation exposure of LDEF: Initial results

    NASA Technical Reports Server (NTRS)

    Benton, E. V.; Frank, A. L.; Benton, E. R.; Csige, I.; Parnell, T. A.; Watts, J. W., Jr.

    1992-01-01

    Initial results from LDEF include radiation detector measurements from four experiments, P0006, P0004, M0004, and A0015. The detectors were located on both the leading and trailing edges of the orbiter and also on the Earthside end. This allowed the directional dependence of the incoming radiation to be measured. Total absorbed doses from thermoluminescent detectors (TLDs) verified the predicted spatial east-west dose ratio dependence of a factor approx. 2.5, due to trapped proton anisotropy in the South Atlantic Anomaly. On the trailing edge of the orbiter a range of doses from 6.64 to 2.91 Gy were measured under Al equivalent shielding of 0.42 to 1.11 g/sq cm. A second set of detectors near this location yielded doses of 6.48 to 2.66 Gy under Al equivalent shielding of 0.48 to 15.4 g/sq cm. On the leading edge, doses of 2.58 to 2.10 Gy were found under Al equivalent shielding of 1.37 to 2.90 g/sq cm. Initial charged particle LET (linear energy transfer) spectra, fluxes, doses and dose equivalents, for LET in H2O greater than or = 8 keV/micron, were measured with plastic nuclear track detectors (PNTDs) located in two experiments. Also preliminary data on low energy neutrons were obtained from detectors containing (6)LiF foils.

  3. Digital radiography: image quality and radiation dose.

    PubMed

    Seibert, J Anthony

    2008-11-01

    Digital radiography devices, rapidly replacing analog screen-film detectors, are now common in diagnostic radiological imaging, where implementation has been accelerated by the commodity status of electronic imaging and display systems. The shift from narrow latitude, fixed-speed screen-film detectors to wide latitude, variable-speed digital detectors has created a flexible imaging system that can easily result in overexposures to the patient without the knowledge of the operator, thus potentially increasing the radiation burden of the patient population from radiographic examinations. In addition, image processing can be inappropriately applied causing inconsistent or artifactual appearance of anatomy, which can lead to misdiagnosis. On the other hand, many advantages can be obtained from the variable-speed digital detector, such as an ability to lower dose in many examinations, image post-processing for disease-specific conditions, display flexibility to change the appearance of the image and aid the physician in making a differential diagnosis, and easy access to digital images. An understanding of digital radiography is necessary to minimize the possibility of overexposures and inconsistent results, and to achieve the principle of as low as reasonably achievable (ALARA) for the safe and effective care of all patients. Thus many issues must be considered for optimal implementation of digital radiography, as reviewed in this article.

  4. Radiation-induced biomarkers for the detection and assessment of absorbed radiation doses

    PubMed Central

    Rana, Sudha; Kumar, Raj; Sultana, Sarwat; Sharma, Rakesh Kumar

    2010-01-01

    Radiation incident involving living organisms is an uncommon but a very serious situation. The first step in medical management including triage is high-throughput assessment of the radiation dose received. Radiation exposure levels can be assessed from viability of cells, cellular organelles such as chromosome and different intermediate metabolites. Oxidative damages by ionizing radiation result in carcinogenesis, lowering of the immune response and, ultimately, damage to the hematopoietic system, gastrointestinal system and central nervous system. Biodosimetry is based on the measurement of the radiation-induced changes, which can correlate them with the absorbed dose. Radiation biomarkers such as chromosome aberration are most widely used. Serum enzymes such as serum amylase and diamine oxidase are the most promising biodosimeters. The level of gene expression and protein are also good biomarkers of radiation. PMID:21829314

  5. Extended range radiation dose-rate monitor

    DOEpatents

    Valentine, Kenneth H.

    1988-01-01

    An extended range dose-rate monitor is provided which utilizes the pulse pileup phenomenon that occurs in conventional counting systems to alter the dynamic response of the system to extend the dose-rate counting range. The current pulses from a solid-state detector generated by radiation events are amplified and shaped prior to applying the pulses to the input of a comparator. The comparator generates one logic pulse for each input pulse which exceeds the comparator reference threshold. These pulses are integrated and applied to a meter calibrated to indicate the measured dose-rate in response to the integrator output. A portion of the output signal from the integrator is fed back to vary the comparator reference threshold in proportion to the output count rate to extend the sensitive dynamic detection range by delaying the asymptotic approach of the integrator output toward full scale as measured by the meter.

  6. [Mechanism of cytogenetic adaptive response induced by low dose radiation].

    PubMed

    Cai, L; Liu, S

    1990-11-01

    Cytogenetic observation on human lymphocytes indicated that pre-exposure of 10, 50 and 75 mGy X-rays could induced the adaptive response. Experimental results with different temperature treatment showed that the adaptive response induced by low dose radiation could be enhanced by 41 degrees C and 43 degrees C, but inhibited by 4 degrees C in addition the treatment by 41 degrees C for one hour could also cause the adaptive response as did low dose radiation. Results showed that adaptive response induced by low dose radiation (10 or 50 mGy X-rays) could be eliminated by the protein synthesis inhibitor, implying that the adaptive response is related with the metabolism of cells, especially with the production of certain protective proteins.

  7. Radiation exposure of LDEF: Initial results

    NASA Technical Reports Server (NTRS)

    Benton, E. V.; Frank, A. L.; Benton, E. R.; Csige, I.; Parnell, T. A.; Watts, John W., Jr.

    1991-01-01

    Initial results from Long Duration Exposure Facility (LDEF) include radiation detector measurements from four experiments; P0006, P0004, M0004, and A0015. The detectors were located on both the leading and trailing edges of the orbiter and also at the Earthside end. This allowed the directional dependence of the incoming radiation to be measured. Total absorbed doses from thermoluminescent detectors (TLDs) verified the predicted spatial east-west dose dependence of a factor of approx. 2.5, due to trapped proton anisotropy in the South Atlantic Anomaly (SAA). On the trailing edge of the orbiter, a range of doses from 664 to 291 rad were measured under nominal shielding of 0.42 to 8.45 g/sq cm. A second set of detectors near this locations results are also given. On the leading edge, doses of 258 to 210 rad were found under shielding of 1.25 to 2.48 g/sq cm. Initial charged particle LET (linear energy transfer) spectra, fluxes, doses, and dose equivalents, for LET in H2O greater than or = 5 keV/micron, were measured with plastic nuclear track detectors located in the four experiments. Also, preliminary data on low energy neutrons were obtained from detectors containing (6)LiF foils.

  8. Radiation exposure of LDEF: Initial results

    NASA Technical Reports Server (NTRS)

    Benton, E. V.; Frank, A. L.; Benton, E. R.; Csige, I.; Parnell, T. A.; Watts, John W., Jr.

    1991-01-01

    Initial results from Long Duration Exposure Facility (LDEF) include radiation detector measurements from four experiments; P0006, P0004, M0004, and A0015. The detectors were located on both the leading and trailing edges of the orbiter and also at the Earthside end. This allowed the directional dependence of the incoming radiation to be measured. Total absorbed doses from thermoluminescent detectors (TLDs) verified the predicted spatial east-west dose dependence of a factor of approx. 2.5, due to trapped proton anisotropy in the South Atlantic Anomaly (SAA). On the trailing edge of the orbiter, a range of doses from 664 to 291 rad were measured under nominal shielding of 0.42 to 8.45 g/sq cm. A second set of detectors near this locations results are also given. On the leading edge, doses of 258 to 210 rad were found under shielding of 1.25 to 2.48 g/sq cm. Initial charged particle LET (linear energy transfer) spectra, fluxes, doses, and dose equivalents, for LET in H2O greater than or = 5 keV/micron, were measured with plastic nuclear track detectors located in the four experiments. Also, preliminary data on low energy neutrons were obtained from detectors containing (6)LiF foils.

  9. Ependymomas: results of radiation treatment

    SciTech Connect

    Garrett, P.G.; Simpson, W.J.K.

    1983-08-01

    Between 1958 and 1980, 102 patients with the diagnosis of ependymoma were seen at the Princess Margaret Hospital. Eleven patients had recurrent disease or were treated elsewhere and 91 patients received radiation therapy following their primary surgical procedure. Fifty patients had cranial tumors and 41 had spinal tumors. The overall survival at five years was 60% and at 10 years was 54%. Those patients with spinal tumors did significantly better with a five year survival of 83% versus 43% for the group with cranial tumors. The other prognostic factors included tumor grade, functional status, age of the patient and interval from surgery to radiation. The most common site of relapse was at the original tumor location, but five patients did show spread through the craniospinal axis. An analysis of dose and the volume treated are made and recommendations for therapy given.

  10. Methods for estimating radiation doses received by commercial aircrew.

    PubMed

    Lantos, Pierre; Fuller, Nicolas; Bottollier-Depois, Jean-François

    2003-07-01

    Radiation doses received onboard aircraft are monitored in Europe to protect aircrew in accordance with a European Union directive. The French Aviation Authorities have developed a system called SIEVERT, using calculation codes to monitor effective radiation doses. For the galactic cosmic ray component, a 3-D world map of effective dose rates is computed using available operational codes. Detailed flight plans are used to ensure sufficient precision. For the solar particle event component, a semi-empirical model called SiGLE has been developed to calculate a time-dependent map of effective dose rates in the course of the event. SiGLE is based on particle transport code results and measurements during solar particle events onboard Concorde airplanes. We present a comparison of the calculated effective radiation dose and measured dose equivalent for various flights onboard Air France aircraft. The agreement is within 15%, which is about the precision of the state-of-the-art dosimetric measurements. Meteorological effects on the dose calculation appear to be negligible. Preliminary results based on solar particle events observed since 1942 with ionization chambers and neutron monitors are given. The present analysis shows that for the galactic cosmic ray component, monthly world maps based on neutron monitor observations are sufficient to ensure a precision of about 20% on the dose estimate for each flight. For the past 40 yr, according to the model SiGLE, none of the solar events has given an effective radiation dose larger than 1 mSv for flights on the most exposed routes.

  11. 42 CFR 81.6 - Use of radiation dose information.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Use of radiation dose information. 81.6 Section 81... Probability of Causation § 81.6 Use of radiation dose information. Determining probability of causation will require the use of radiation dose information provided to DOL by the National Institute for...

  12. 42 CFR 81.6 - Use of radiation dose information.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Use of radiation dose information. 81.6 Section 81... Probability of Causation § 81.6 Use of radiation dose information. Determining probability of causation will require the use of radiation dose information provided to DOL by the National Institute for Occupational...

  13. 42 CFR 81.6 - Use of radiation dose information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Use of radiation dose information. 81.6 Section 81... Probability of Causation § 81.6 Use of radiation dose information. Determining probability of causation will require the use of radiation dose information provided to DOL by the National Institute for Occupational...

  14. 42 CFR 81.6 - Use of radiation dose information.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Use of radiation dose information. 81.6 Section 81... Probability of Causation § 81.6 Use of radiation dose information. Determining probability of causation will require the use of radiation dose information provided to DOL by the National Institute for Occupational...

  15. 42 CFR 81.6 - Use of radiation dose information.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Use of radiation dose information. 81.6 Section 81... Probability of Causation § 81.6 Use of radiation dose information. Determining probability of causation will require the use of radiation dose information provided to DOL by the National Institute for Occupational...

  16. A molecular fraction method for measuring personnel radiation doses

    NASA Astrophysics Data System (ADS)

    Fadel, M. A.; Khalil, W. A.; Krodja, R. P.; Sheta, N.; Abd El-Baset, M. S.

    1987-02-01

    This work represents a development in fast and albedo neutron and gamma ray dosimetry, using cellulose nitrate, as a tissue equivalent material, in which radiation damage was registered. The changes in molecular fractions of the polymer were measured after irradiation with neutron fluences from a 252Cf source in the range 10 5-10 10 n/cm 2 and gamma doses in the range 10 -4-10 -1 Gy through the use of gel filtration chromatography. Effects of irradiation on phantom, phantom to dosimeter distance, phantom thickness and storage at extreme environmental conditions were studied on the detector response and readout. The results showed that main chain scission followed by formation of new molecular configurations is the predominant effect of radiation on the polymer. The method enables measurements of neutron fluences and gamma doses in mixed radiation fields. Empirical formulae for calculating the absorbed dose from the measured changes in molecular fraction intensities are given.

  17. Alanine Dosimetry Accurately Determines Radiation Dose in Nonhuman Primates

    DTIC Science & Technology

    2007-10-01

    b) utility of CIP in managing postirradiation infection related to bacterial translocation from the alimentary canal, and (c) side effects of...sequelae seen after these ra- diation doses and prior to death (and at post mortem) is infection , generally of an endog- enous origin arising from...promised situations, can result in opportu- nistic infections . Radiation dose selection Taken together, these data support the use of 6.5 Gy cobalt-60

  18. Preliminary results of radiation measurements on EURECA

    SciTech Connect

    Benton, E.V.; Frank, A.L.

    1995-03-01

    The eleven-month duration of the EURECA mission allows long-term radiation effects to be studied similarly to those of the Long Duration Exposure Facility (LDEF). Basic data can be generated for projections to crew doses and electronic and computer reliability on spacecraft missions. A radiation experiment has been designed for EURECA which uses passive integrating detectors to measure average radiation levels. The components include a Trackoscope, which employs fourteen plastic nuclear track detector (PNTD) stacks to measure the angular dependence of high LET (greater than or equal to 6 keV/micro m) radiation. Also included are TLD`s for total absorbed doses, thermal/resonance neutron detectors (TRND`s) for low energy neutron fluences and a thick PNTD stack for depth dependence measurements. LET spectra are derived from the PNTD measurements. Preliminary TLD results from seven levels within the detector array show that integrated dose inside the flight canister varied from 18.8 +/- 0.6 cGy to 38.9 +/- 1.2 cGy. The TLD`s oriented toward the least shielded direction averaged 53% higher in dose than those oriented away from the least shielded direction (minimum shielding toward the least shielded direction varied from 1.13 to 7.9 g/cm(exp 2), Al equivalent). The maximum dose rate on EURECA (1.16 mGy/day) was 37% of the maximum measured on LDEF and dose rates at all depths were less than measured on LDEF. The shielding external to the flight canister covered a greater solid angle about the canister than the LDEF experiments.

  19. Radiation dose from cardiac computed tomography before and after implementation of radiation dose-reduction techniques.

    PubMed

    Raff, Gilbert L; Chinnaiyan, Kavitha M; Share, David A; Goraya, Tauqir Y; Kazerooni, Ella A; Moscucci, Mauro; Gentry, Ralph E; Abidov, Aiden

    2009-06-10

    Cardiac computed tomography angiography (CCTA) can accurately diagnose coronary artery disease, but radiation dose from this procedure is of concern. To determine whether a collaborative radiation dose-reduction program would be associated with reduced radiation dose in patients undergoing CCTA in a statewide registry over a 1-year period and to define its effect on image quality. A prospective, controlled, nonrandomized study conducted during a control period (July-August 2007), an intervention period (September 2007-April 2008), and a follow-up period (May-June 2008) at 15 hospital imaging centers participating in the Advanced Cardiovascular Imaging Consortium in Michigan, which included small community hospitals and large academic medical centers. A total of 4995 sequential patients undergoing CCTA for suspected coronary artery disease were enrolled; 4862 patients (97.3%) had complete radiation data for analysis. A best-practice CCTA scan model was used, which included minimized scan range, heart rate reduction, electrocardiographic-gated tube current modulation, and reduced tube voltage in suitable patients. Primary outcomes included dose-length product and effective radiation dose from all phases of the CCTA scan. Secondary outcomes were image quality assessed by a 4-point scale (1 indicated excellent; 2, good; 3, adequate; and 4, nondiagnostic) and frequency of diagnostic-quality scans. Compared with the control period, patients' estimated median radiation dose in the follow-up period was reduced by 53.3% (dose-length product decreased from 1493 mGy x cm [interquartile range {IQR}, 855-1823 mGy x cm] to 697 mGy x cm [IQR, 407-1163 mGy x cm]; P < .001) and effective dose from 21 mSv (IQR, 12-26 mSv) to 10 mSv (IQR, 6-16 mSv) (P < .001). The greatest reduction in dose occurred at low-volume sites. There were no significant changes in median image quality assessment during the control period compared with the follow-up period (median image quality of 2 [images

  20. Space Radiation Absorbed Dose Distribution in a Human Phantom Torso

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Yang, T.; Atwell, W.

    2000-01-01

    The flight of a human phantom torso with head that containing active dosimeters at 5 organ sites and 1400 TLDs distributed in 34 1" thick sections is described. Experimental dose rates and quality factors are compared with calculations for shielding distributions at the sites using the Computerized Anatomical Male (CAM) model. The measurements were complemented with those obtained from other instruments. These results have provided the most comprehensive data set to map the dose distribution inside a human and to assess the accuracy of radiation transport models and astronaut radiation risk.

  1. Radiation Dose and Safety in Cardiac Computed Tomography

    PubMed Central

    Gerber, Thomas C; Kantor, Birgit; McCollough, Cynthia H.

    2009-01-01

    Synopsis As a result of the changes in utilization of imaging procedures that rely on ionizing radiation, the collective dose has increased by over 700% and the annual per-capita dose, by almost 600% over recent years. It is certainly possible that this growing use may have significant effects on public health. Although there are uncertainties related to the accuracy of calculated radiation exposure and the estimated biologic risk, there are measures that can be taken to reduce any potential risks while maintaining diagnostic accuracy. This article will review the existing data regarding biological hazards of radiation exposure associated to medical diagnostic testing, the methodology used to estimate radiation exposure and the measures that can be taken to effectively reduce it. PMID:19766923

  2. Ultraviolet radiation therapy and UVR dose models

    SciTech Connect

    Grimes, David Robert

    2015-01-15

    Ultraviolet radiation (UVR) has been an effective treatment for a number of chronic skin disorders, and its ability to alleviate these conditions has been well documented. Although nonionizing, exposure to ultraviolet (UV) radiation is still damaging to deoxyribonucleic acid integrity, and has a number of unpleasant side effects ranging from erythema (sunburn) to carcinogenesis. As the conditions treated with this therapy tend to be chronic, exposures are repeated and can be high, increasing the lifetime probability of an adverse event or mutagenic effect. Despite the potential detrimental effects, quantitative ultraviolet dosimetry for phototherapy is an underdeveloped area and better dosimetry would allow clinicians to maximize biological effect whilst minimizing the repercussions of overexposure. This review gives a history and insight into the current state of UVR phototherapy, including an overview of biological effects of UVR, a discussion of UVR production, illness treated by this modality, cabin design and the clinical implementation of phototherapy, as well as clinical dose estimation techniques. Several dose models for ultraviolet phototherapy are also examined, and the need for an accurate computational dose estimation method in ultraviolet phototherapy is discussed.

  3. Ultraviolet radiation therapy and UVR dose models.

    PubMed

    Grimes, David Robert

    2015-01-01

    Ultraviolet radiation (UVR) has been an effective treatment for a number of chronic skin disorders, and its ability to alleviate these conditions has been well documented. Although nonionizing, exposure to ultraviolet (UV) radiation is still damaging to deoxyribonucleic acid integrity, and has a number of unpleasant side effects ranging from erythema (sunburn) to carcinogenesis. As the conditions treated with this therapy tend to be chronic, exposures are repeated and can be high, increasing the lifetime probability of an adverse event or mutagenic effect. Despite the potential detrimental effects, quantitative ultraviolet dosimetry for phototherapy is an underdeveloped area and better dosimetry would allow clinicians to maximize biological effect whilst minimizing the repercussions of overexposure. This review gives a history and insight into the current state of UVR phototherapy, including an overview of biological effects of UVR, a discussion of UVR production, illness treated by this modality, cabin design and the clinical implementation of phototherapy, as well as clinical dose estimation techniques. Several dose models for ultraviolet phototherapy are also examined, and the need for an accurate computational dose estimation method in ultraviolet phototherapy is discussed.

  4. Impact of Drug Therapy, Radiation Dose, and Dose Rate on Renal Toxicity Following Bone Marrow Transplantation

    SciTech Connect

    Cheng, Jonathan C.; Schultheiss, Timothy E. Wong, Jeffrey Y.C.

    2008-08-01

    Purpose: To demonstrate a radiation dose response and to determine the dosimetric and chemotherapeutic factors that influence the incidence of late renal toxicity following total body irradiation (TBI). Methods and Materials: A comprehensive retrospective review was performed of articles reporting late renal toxicity, along with renal dose, fractionation, dose rate, chemotherapy regimens, and potential nephrotoxic agents. In the final analysis, 12 articles (n = 1,108 patients), consisting of 24 distinct TBI/chemotherapy conditioning regimens were included. Regimens were divided into three subgroups: adults (age {>=}18 years), children (age <18 years), and mixed population (both adults and children). Multivariate logistic regression was performed to identify dosimetric and chemotherapeutic factors significantly associated with late renal complications. Results: Individual analysis was performed on each population subgroup. For the purely adult population, the only significant variable was total dose. For the mixed population, the significant variables included total dose, dose rate, and the use of fludarabine. For the pediatric population, only the use of cyclosporin or teniposide was significant; no dose response was noted. A logistic model was generated with the exclusion of the pediatric population because of its lack of dose response. This model yielded the following significant variables: total dose, dose rate, and number of fractions. Conclusion: A dose response for renal damage after TBI was identified. Fractionation and low dose rates are factors to consider when delivering TBI to patients undergoing bone marrow transplantation. Drug therapy also has a major impact on kidney function and can modify the dose-response function.

  5. Optimizing Radiation Doses for Computed Tomography Across Institutions: Dose Auditing and Best Practices.

    PubMed

    Demb, Joshua; Chu, Philip; Nelson, Thomas; Hall, David; Seibert, Anthony; Lamba, Ramit; Boone, John; Krishnam, Mayil; Cagnon, Christopher; Bostani, Maryam; Gould, Robert; Miglioretti, Diana; Smith-Bindman, Rebecca

    2017-06-01

    the audit and meeting, head CT doses varied less, although some institutions increased and some decreased mean head CT doses and the proportion above benchmarks. Reviewing institutional doses and sharing dose-optimization best practices resulted in lower radiation doses for chest and abdominal CT and more consistent doses for head CT.

  6. High-Dose Hypofractionated Proton Beam Radiation Therapy Is Safe and Effective for Central and Peripheral Early-Stage Non-Small Cell Lung Cancer: Results of a 12-Year Experience at Loma Linda University Medical Center

    SciTech Connect

    Bush, David A.; Cheek, Gregory; Zaheer, Salman; Wallen, Jason; Mirshahidi, Hamid; Katerelos, Ari; Grove, Roger; Slater, Jerry D.

    2013-08-01

    Purpose: We update our previous reports on the use of hypofractionated proton beam radiation therapy for early-stage lung cancer patients. Methods and Materials: Eligible subjects had biopsy-proven non-small cell carcinoma of the lung and were medically inoperable or refused surgery. Clinical workup required staging of T1 or T2, N0, M0. Subjects received hypofractionated proton beam therapy to the primary tumor only. The dose delivered was sequentially escalated from 51 to 60 Gy, then to 70 Gy in 10 fractions over 2 weeks. Endpoints included toxicity, pulmonary function, overall survival (OS), disease-specific survival (DSS), and local control (LC). Results: One hundred eleven subjects were analyzed for treatment outcomes. The patient population had the following average characteristics; age 73.2 years, tumor size 3.6 cm, and 1.33 L forced expiratory volume in 1 second. The entire group showed improved OS with increasing dose level (51, 60, and 70 Gy) with a 4-year OS of 18%, 32%, and 51%, respectively (P=.006). Peripheral T1 tumors exhibited LC of 96%, DSS of 88%, and OS of 60% at 4 years. Patients with T2 tumors showed a trend toward improved LC and survival with the 70-Gy dose level. On multivariate analysis, larger tumor size was strongly associated with increased local recurrence and decreased survival. Central versus peripheral location did not correlate with any outcome measures. Clinical radiation pneumonitis was not found to be a significant complication, and no patient required steroid therapy after treatment for radiation pneumonitis. Pulmonary function was well maintained 1 year after treatment. Conclusions: High-dose hypofractionated proton therapy achieves excellent outcomes for lung carcinomas that are peripherally or centrally located. The 70-Gy regimen has been adopted as standard therapy for T1 tumors at our institution. Larger T2 tumors show a trend toward improved outcomes with higher doses, suggesting that better results could be seen with

  7. Radiation Dose from Medical Imaging: A Primer for Emergency Physicians

    PubMed Central

    Jones, Jesse G.A; Mills, Christopher N.; Mogensen, Monique A.; Lee, Christoph I.

    2012-01-01

    Introduction Medical imaging now accounts for most of the US population's exposure to ionizing radiation. A substantial proportion of this medical imaging is ordered in the emergency setting. We aim to provide a general overview of radiation dose from medical imaging with a focus on computed tomography, as well as a literature review of recent efforts to decrease unnecessary radiation exposure to patients in the emergency department setting. Methods We conducted a literature review through calendar year 2010 for all published articles pertaining to the emergency department and radiation exposure. Results The benefits of imaging usually outweigh the risks of eventual radiation-induced cancer in most clinical scenarios encountered by emergency physicians. However, our literature review identified 3 specific clinical situations in the general adult population in which the lifetime risks of cancer may outweigh the benefits to the patient: rule out pulmonary embolism, flank pain, and recurrent abdominal pain in inflammatory bowel disease. For these specific clinical scenarios, a physician-patient discussion about such risks and benefits may be warranted. Conclusion Emergency physicians, now at the front line of patients' exposure to ionizing radiation, should have a general understanding of the magnitude of radiation dose from advanced medical imaging procedures and their associated risks. Future areas of research should include the development of protocols and guidelines that limit unnecessary patient radiation exposure. PMID:22900113

  8. Radiation dose study in nuclear medicine using GATE

    NASA Astrophysics Data System (ADS)

    Aguwa, Kasarachi

    Dose as a result of radiation exposure is the notion generally used to disclose the imparted energy in a volume of tissue to a potential biological effect. The basic unit defined by the international system of units (SI system) is the radiation absorbed dose, which is expressed as the mean imparted energy in a mass element of the tissue known as "gray" (Gy) or J/kg. The procedure for ascertaining the absorbed dose is complicated since it involves the radiation transport of numerous types of charged particles and coupled photon interactions. The most precise method is to perform a full 3D Monte Carlo simulation of the radiation transport. There are various Monte Carlo toolkits that have tool compartments for dose calculations and measurements. The dose studies in this thesis were performed using the GEANT4 Application for Emission Tomography (GATE) software (Jan et al., 2011) GATE simulation toolkit has been used extensively in the medical imaging community, due to the fact that it uses the full capabilities of GEANT4. It also utilizes an easy to-learn GATE macro language, which is more accessible than learning the GEANT4/C++ programming language. This work combines GATE with digital phantoms generated using the NCAT (NURBS-based cardiac-torso phantom) toolkit (Segars et al., 2004) to allow efficient and effective estimation of 3D radiation dose maps. The GATE simulation tool has developed into a beneficial tool for Monte Carlo simulations involving both radiotherapy and imaging experiments. This work will present an overview of absorbed dose of common radionuclides used in nuclear medicine and serve as a guide to a user who is setting up a GATE simulation for a PET and SPECT study.

  9. Can radiation therapy treatment planning system accurately predict surface doses in postmastectomy radiation therapy patients?

    SciTech Connect

    Wong, Sharon; Back, Michael; Tan, Poh Wee; Lee, Khai Mun; Baggarley, Shaun; Lu, Jaide Jay

    2012-07-01

    Skin doses have been an important factor in the dose prescription for breast radiotherapy. Recent advances in radiotherapy treatment techniques, such as intensity-modulated radiation therapy (IMRT) and new treatment schemes such as hypofractionated breast therapy have made the precise determination of the surface dose necessary. Detailed information of the dose at various depths of the skin is also critical in designing new treatment strategies. The purpose of this work was to assess the accuracy of surface dose calculation by a clinically used treatment planning system and those measured by thermoluminescence dosimeters (TLDs) in a customized chest wall phantom. This study involved the construction of a chest wall phantom for skin dose assessment. Seven TLDs were distributed throughout each right chest wall phantom to give adequate representation of measured radiation doses. Point doses from the CMS Xio Registered-Sign treatment planning system (TPS) were calculated for each relevant TLD positions and results correlated. There were no significant difference between measured absorbed dose by TLD and calculated doses by the TPS (p > 0.05 (1-tailed). Dose accuracy of up to 2.21% was found. The deviations from the calculated absorbed doses were overall larger (3.4%) when wedges and bolus were used. 3D radiotherapy TPS is a useful and accurate tool to assess the accuracy of surface dose. Our studies have shown that radiation treatment accuracy expressed as a comparison between calculated doses (by TPS) and measured doses (by TLD dosimetry) can be accurately predicted for tangential treatment of the chest wall after mastectomy.

  10. Radiation doses in paediatric interventional cardiology procedures.

    PubMed

    Tsapaki, Virginia; Kottou, Sofia; Korniotis, Sarantis; Nikolaki, Niki; Rammos, Spyridon; Apostolopoulou, Sotiria C

    2008-01-01

    The objective was to investigate paediatric doses in coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) in the largest cardiac hospital in Greece. Forty procedures were carried out by two board-certified senior interventional cardiologists. Data collected were: patient weight, height, age, fluoroscopy time (FT), total number of images (N) and kerma-area product (KAP). Median (range) age was 7.5 y (17 d to 17 y). Median FT, N and KAP were 4 min, 655, 2.1 Gy cm2 for CA and 12.1 min, 1296, 14.7 Gy cm2 for PTCA (corresponding adult diagnostic reference levels (DRLs) are: 6.5 min, 700, 45 Gy cm2 for CA and 15.5 min, 1000 and 85 Gy cm2 for PTCA). The highest percentage of cine dose was in newborns (0-1 y) (CA: 92% and PTCA: 100%). As age increased, cine dose percentage decreased, whereas total radiation dose increased. Median paediatric FT and N recorded reached or even exceeded adult DRL and should be optimised. Paediatric DRL should be set.

  11. Radiation dose to physicians’ eye lens during interventional radiology

    NASA Astrophysics Data System (ADS)

    Bahruddin, N. A.; Hashim, S.; Karim, M. K. A.; Sabarudin, A.; Ang, W. C.; Salehhon, N.; Bakar, K. A.

    2016-03-01

    The demand of interventional radiology has increased, leading to significant risk of radiation where eye lens dose assessment becomes a major concern. In this study, we investigate physicians' eye lens doses during interventional procedures. Measurement were made using TLD-100 (LiF: Mg, Ti) dosimeters and was recorded in equivalent dose at a depth of 0.07 mm, Hp(0.07). Annual Hp(0.07) and annual effective dose were estimated using workload estimation for a year and Von Boetticher algorithm. Our results showed the mean Hp(0.07) dose of 0.33 mSv and 0.20 mSv for left and right eye lens respectively. The highest estimated annual eye lens dose was 29.33 mSv per year, recorded on left eye lens during fistulogram procedure. Five physicians had exceeded 20 mSv dose limit as recommended by international commission of radiological protection (ICRP). It is suggested that frequent training and education on occupational radiation exposure are necessary to increase knowledge and awareness of the physicians’ thus reducing dose during the interventional procedure.

  12. Estimating the Radiation Dose to the Fetus in Prophylactic Internal Iliac Artery Balloon Occlusion: Three Cases

    PubMed Central

    Kai, Kentaro; Hamada, Tomohiro; Yuge, Akitoshi; Kiyosue, Hiro; Nishida, Yoshihiro; Nasu, Kaei; Narahara, Hisashi

    2015-01-01

    Background. Although radiation exposure is of great concern to expecting patients, little information is available on the fetal radiation dose associated with prophylactic internal iliac artery balloon occlusion (IIABO). Here we estimated the fetal radiation dose associated with prophylactic IIABO in Caesarean section (CS). Cases. We report our experience with the IIABO procedure in three consecutive patients with suspected placenta previa/accreta. Fetal radiation dose measurements were conducted prior to each CS by using an anthropomorphic phantom. Based on the simulated value, we calculated the fetal radiation dose as the absorbed dose. We found that the fetal radiation doses ranged from 12.88 to 31.6 mGy. The fetal radiation dose during the prophylactic IIABOs did not exceed 50 mGy. Conclusion. The IIABO procedure could result in a very small increase in the risk of harmful effects to the fetus. PMID:26180648

  13. High-dose hypofractionated proton beam radiation therapy is safe and effective for central and peripheral early-stage non-small cell lung cancer: results of a 12-year experience at Loma Linda University Medical Center.

    PubMed

    Bush, David A; Cheek, Gregory; Zaheer, Salman; Wallen, Jason; Mirshahidi, Hamid; Katerelos, Ari; Grove, Roger; Slater, Jerry D

    2013-08-01

    We update our previous reports on the use of hypofractionated proton beam radiation therapy for early-stage lung cancer patients. Eligible subjects had biopsy-proven non-small cell carcinoma of the lung and were medically inoperable or refused surgery. Clinical workup required staging of T1 or T2, N0, M0. Subjects received hypofractionated proton beam therapy to the primary tumor only. The dose delivered was sequentially escalated from 51 to 60 Gy, then to 70 Gy in 10 fractions over 2 weeks. Endpoints included toxicity, pulmonary function, overall survival (OS), disease-specific survival (DSS), and local control (LC). One hundred eleven subjects were analyzed for treatment outcomes. The patient population had the following average characteristics; age 73.2 years, tumor size 3.6 cm, and 1.33 L forced expiratory volume in 1 second. The entire group showed improved OS with increasing dose level (51, 60, and 70 Gy) with a 4-year OS of 18%, 32%, and 51%, respectively (P=.006). Peripheral T1 tumors exhibited LC of 96%, DSS of 88%, and OS of 60% at 4 years. Patients with T2 tumors showed a trend toward improved LC and survival with the 70-Gy dose level. On multivariate analysis, larger tumor size was strongly associated with increased local recurrence and decreased survival. Central versus peripheral location did not correlate with any outcome measures. Clinical radiation pneumonitis was not found to be a significant complication, and no patient required steroid therapy after treatment for radiation pneumonitis. Pulmonary function was well maintained 1 year after treatment. High-dose hypofractionated proton therapy achieves excellent outcomes for lung carcinomas that are peripherally or centrally located. The 70-Gy regimen has been adopted as standard therapy for T1 tumors at our institution. Larger T2 tumors show a trend toward improved outcomes with higher doses, suggesting that better results could be seen with intensified treatment. Copyright © 2013 Elsevier Inc. All

  14. The Monte Carlo calculation of integral radiation dose in xeromammography.

    PubMed

    Dance, D R

    1980-01-01

    A Monte Carlo computer program has been developed for the computation of integral radiation dose to the breast in xeromammography. The results are given in terms of the integral dose per unit area of the breast per unit incident exposure. The calculations have been made for monoenergetic incident photons and the results integrated over a variety of X-ray spectra from both tungsten and molybdenum targets. This range incorporates qualities used in conventional and xeromammography. The program includes the selenium plate used in xeroradiography; the energy absorbed in this detector has also been investigated. The latter calculations have been used to predict relative values of exposure and of integral dose to the breast for xeromammograms taken at various radiation qualities. The results have been applied to recent work on the reduction of patient exposure in xeromammography by the addition of aluminium filters to the X-ray beam.

  15. Prototype Operational Advances for Atmospheric Radiation Dose Rate Specification

    NASA Astrophysics Data System (ADS)

    Tobiska, W. K.; Bouwer, D.; Bailey, J. J.; Didkovsky, L. V.; Judge, K.; Garrett, H. B.; Atwell, W.; Gersey, B.; Wilkins, R.; Rice, D.; Schunk, R. W.; Bell, D.; Mertens, C. J.; Xu, X.; Crowley, G.; Reynolds, A.; Azeem, I.; Wiltberger, M. J.; Wiley, S.; Bacon, S.; Teets, E.; Sim, A.; Dominik, L.

    2014-12-01

    Space weather's effects upon the near-Earth environment are due to dynamic changes in the energy transfer processes from the Sun's photons, particles, and fields. The coupling between the solar and galactic high-energy particles, the magnetosphere, and atmospheric regions can significantly affect humans and our technology as a result of radiation exposure. Space Environment Technologies (SET) has developed innovative, new space weather observations that will become part of the toolset that is transitioned into operational use. One prototype operational system for providing timely information about the effects of space weather is SET's Automated Radiation Measurements for Aerospace Safety (ARMAS) system. ARMAS will provide the "weather" of the radiation environment to improve aircraft crew and passenger safety. Through several dozen flights the ARMAS project has successfully demonstrated the operation of a micro dosimeter on commercial aviation altitude aircraft that captures the real-time radiation environment resulting from Galactic Cosmic Rays and Solar Energetic Particles. The real-time radiation exposure is computed as an effective dose rate (body-averaged over the radiative-sensitive organs and tissues in units of microsieverts per hour); total ionizing dose is captured on the aircraft, downlinked in real-time via Iridium satellites, processed on the ground into effective dose rates, compared with NASA's Langley Research Center (LaRC) most recent Nowcast of Atmospheric Ionizing Radiation System (NAIRAS) global radiation climatology model runs, and then made available to end users via the web and smart phone apps. We are extending the dose measurement domain above commercial aviation altitudes into the stratosphere with a collaborative project organized by NASA's Armstrong Flight Research Center (AFRC) called Upper-atmospheric Space and Earth Weather eXperiment (USEWX). In USEWX we will be flying on the ER-2 high altitude aircraft a micro dosimeter for

  16. [Sensitivity of Jatropha curcas seeds to (60)Co-gamma radiation and their medial lethal doses in radiation breeding].

    PubMed

    Wang, Zhao-Yu; Lin, Jing-Ming; Luo, Li; Xu, Zeng-Fu

    2009-03-01

    To study the sensitivity of Jatropha curcas seeds from three different locations to (60)Co-gamma radiation and to determine the medial lethal doses (LD50) of (60)Co-gamma radiation for these seeds. Six different radiation doses (0, 100, 150, 200, 250 and 300 Gy) were used. Based on the germination rate 50%, LD50 doses of (60)Co-gamma radiation for the seeds were calculated using linear regression equation. LD50 doses of (60)Co-gamma radiation for these seeds were 178 Gy (seeds from Guangdong), 132 Gy (seeds from Hainan) and 198 Gy (seeds from India) respectively. Increasing radiation doses caused more significant changes in leaf shape of the M1 seedlings. The results provides an important experimental basis for the radiation breeding of the important herbal and energy plant J. curcas.

  17. Imaging practices and radiation doses from imaging in radiotherapy.

    PubMed

    Siiskonen, Teemu; Kaijaluoto, Sampsa; Florea, Tudor

    2017-03-25

    Modern radiotherapy treatments require frequent imaging for accurate patient positioning relative to the therapeutic radiation beam. Imaging practices in five Finnish radiotherapy clinics were assessed and discussed from the patient dose optimization point of view. The results show that imaging strategies are not jointly established and variations exist. The organ absorbed doses depend on imaging technique and imaging frequency. In particular, organ doses from the cone beam computed tomography can have very large variations (a factor of 10-50 in breast imaging and factor of 5 in prostate imaging). The cumulative imaging organ dose from the treatment can vary by a factor of ten or more for the same treatment, depending on the chosen technique and imaging frequency. Awareness and optimization of the imaging dose in image-guided radiotherapy should be strengthened.

  18. Relevance of biotic pathways to the long-term regulation of nuclear waste disposal. Estimation of radiation dose to man resulting from biotic transport: the BIOPORT/MAXI1 software package. Volume 5

    SciTech Connect

    McKenzie, D.H.; Cadwell, L.L.; Gano, K.A.; Kennedy, W.E. Jr.; Napier, B.A.; Peloquin, R.A.; Prohammer, L.A.; Simmons, M.A.

    1985-10-01

    BIOPORT/MAXI1 is a collection of five computer codes designed to estimate the potential magnitude of the radiation dose to man resulting from biotic transport processes. Dose to man is calculated for ingestion of agricultural crops grown in contaminated soil, inhalation of resuspended radionuclides, and direct exposure to penetrating radiation resulting from the radionuclide concentrations established in the available soil surface by the biotic transport model. This document is designed as both an instructional and reference document for the BIOPORT/MAXI1 computer software package and has been written for two major audiences. The first audience includes persons concerned with the mathematical models of biological transport of commercial low-level radioactive wastes and the computer algorithms used to implement those models. The second audience includes persons concerned with exercising the computer program and exposure scenarios to obtain results for specific applications. The report contains sections describing the mathematical models, user operation of the computer programs, and program structure. Input and output for five sample problems are included. In addition, listings of the computer programs, data libraries, and dose conversion factors are provided in appendices.

  19. Follow-Up Study on Fetal CT Radiation Dose in Japan: Validating the Decrease in Radiation Dose.

    PubMed

    Miyazaki, Osamu; Sawai, Hideaki; Yamada, Takahiro; Murotsuki, Jun; Nishimura, Gen

    2017-04-01

    In 2011, we collected data on fetal CT radiation dose to determine the diagnostic reference level (DRL); however, continuous evaluation of the DRL is necessary. The hypothesis of this study is that the fetal CT radiation dose has decreased, and we predict a widespread use of iterative reconstruction (IR). We also predict that the national decrease in exposure is because of the DRL reported as a result of the previous national study. Various testing protocols from each site were summarized as part of the study results. The minimum, one-fourth (25th percentile), median, three-fourths (75th percentile), and maximum values were obtained for volume CT dose index (CTDIvol), dose-length product (DLP), and scan length of 120 fetal CT examinations. The trends for IR usage and tube voltage were also investigated. Compared to the results of the 2011 study (n = 119), the minimum, 25th percentile, median, and 75th percentile values for CTDIvol and DLP have decreased for the tabulated results in 2015 (n = 120). The 75th percentile value for CTDIvol was 4.9 mGy, which is 43% of the previous value. IR was used in 70% of the sites. The radiation dose was significantly lower among groups that used IR. Four years passed between our initial survey on DRL and the present follow-up survey, and it appears that the previous report sufficiently fulfilled its objective and role in contributing to the decrease in DRL observed in this follow-up study.

  20. Radiation dose-rate meter using an energy-sensitive counter

    DOEpatents

    Kopp, Manfred K.

    1988-01-01

    A radiation dose-rate meter is provided which uses an energy-sensitive detector and combines charge quantization and pulse-rate measurement to monitor radiation dose rates. The charge from each detected photon is quantized by level-sensitive comparators so that the resulting total output pulse rate is proportional to the dose-rate.

  1. Radiation Dose-Volume Effects of Optic Nerves and Chiasm

    SciTech Connect

    Mayo, Charles; Martel, Mary K.; Marks, Lawrence B.; Flickinger, John; Nam, Jiho; Kirkpatrick, John

    2010-03-01

    Publications relating radiation toxicity of the optic nerves and chiasm to quantitative dose and dose-volume measures were reviewed. Few studies have adequate data for dose-volume outcome modeling. The risk of toxicity increased markedly at doses >60 Gy at {approx}1.8 Gy/fraction and at >12 Gy for single-fraction radiosurgery. The evidence is strong that radiation tolerance is increased with a reduction in the dose per fraction. Models of threshold tolerance were examined.

  2. Practical strategies to reduce pediatric CT radiation dose.

    PubMed

    Nelson, Thomas R

    2014-03-01

    The objective of this article is to provide a brief review of CT scanning radiation sensitivity in children and explain CT scan parameters that affect radiation dose. We discuss key factors influencing radiation dose and study quality and how these factors can be used to optimize scan protocols with the goal of reducing pediatric CT radiation dose without compromising diagnostic quality. Finally, we provide some practical tips for reducing radiation doses to children. Copyright © 2014 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  3. Estimation of thyroid radiation doses for the hanford thyroid disease study: results and implications for statistical power of the epidemiological analyses.

    PubMed

    Kopecky, Kenneth J; Davis, Scott; Hamilton, Thomas E; Saporito, Mark S; Onstad, Lynn E

    2004-07-01

    Residents of eastern Washington, northeastern Oregon, and western Idaho were exposed to I released into the atmosphere from operations at the Hanford Nuclear Site from 1944 through 1972, especially in the late 1940's and early 1950's. This paper describes the estimated doses to the thyroid glands of the 3,440 evaluable participants in the Hanford Thyroid Disease Study, which investigated whether thyroid morbidity was increased in people exposed to radioactive iodine from Hanford during 1944-1957. The participants were born during 1940-1946 to mothers living in Benton, Franklin, Walla Walla, Adams, Okanogan, Ferry, or Stevens Counties in Washington State. Whenever possible someone with direct knowledge of the participant's early life (preferably the participant's mother) was interviewed about the participant's individual dose-determining characteristics (residence history, sources and quantities of food, milk, and milk products consumed, production and processing techniques for home-grown food and milk products). Default information was used if no interview respondent was available. Thyroid doses were estimated using the computer program Calculation of Individual Doses from Environmental Radionuclides (CIDER) developed by the Hanford Environmental Dose Reconstruction Project. CIDER provided 100 sets of doses to represent uncertainty of the estimates. These sets were not generated independently for each participant, but reflected the effects of uncertainties in characteristics shared by participants. Estimated doses (medians of each participant's 100 realizations) ranged from 0.0029 mGy to 2823 mGy, with mean and median of 174 and 97 mGy, respectively. The distribution of estimated doses provided the Hanford Thyroid Disease Study with sufficient statistical power to test for dose-response relationships between thyroid outcomes and exposure to Hanford's I.

  4. Measurement of radiation dose in dental radiology.

    PubMed

    Helmrot, Ebba; Alm Carlsson, Gudrun

    2005-01-01

    Patient dose audit is an important tool for quality control and it is important to have a well-defined and easy to use method for dose measurements. In dental radiology, the most commonly used dose parameters for the setting of diagnostic reference levels (DRLs) are the entrance surface air kerma (ESAK) for intraoral examinations and dose width product (DWP) for panoramic examinations. DWP is the air kerma at the front side of the secondary collimator integrated over the collimator width and an exposure cycle. ESAK or DWP is usually measured in the absence of the patient but with the same settings of tube voltage (kV), tube current (mA) and exposure time as with the patient present. Neither of these methods is easy to use, and, in addition, DWP is not a risk related quantity. A better method of monitoring patient dose would be to use a dose area product (DAP) meter for all types of dental examinations. In this study, measurements with a DAP meter are reported for intraoral and panoramic examinations. The DWP is also measured with a pencil ionisation chamber and the product of DWP and the height H (DWP x H) of the secondary collimator (measured using film) was compared to DAP. The results show that it is feasible to measure DAP using a DAP meter for both intraoral and panoramic examinations. The DAP is therefore recommended for the setting of DRLs.

  5. Methionine Uptake and Required Radiation Dose to Control Glioblastoma

    SciTech Connect

    Iuchi, Toshihiko; Hatano, Kazuo; Uchino, Yoshio; Itami, Makiko; Hasegawa, Yuzo; Kawasaki, Koichiro; Sakaida, Tsukasa; Hara, Ryusuke

    2015-09-01

    Purpose: The purpose of this study was to retrospectively assess the feasibility of radiation therapy planning for glioblastoma multiforme (GBM) based on the use of methionine (MET) positron emission tomography (PET), and the correlation among MET uptake, radiation dose, and tumor control. Methods and Materials: Twenty-two patients with GBM who underwent MET-PET prior to radiation therapy were enrolled. MET uptake in 30 regions of interest (ROIs) from 22 GBMs, biologically effective doses (BEDs) for the ROIs and their ratios (MET uptake:BED) were compared in terms of whether the ROIs were controlled for >12 months. Results: MET uptake was significantly correlated with tumor control (odds ratio [OR], 10.0; P=.005); however, there was a higher level of correlation between MET uptake:BED ratio and tumor control (OR, 40.0; P<.0001). These data indicated that the required BEDs for controlling the ROIs could be predicted in terms of MET uptake; BED could be calculated as [34.0 × MET uptake] Gy from the optimal threshold of the MET uptake:BED ratio for tumor control. Conclusions: Target delineation based on MET-PET was demonstrated to be feasible for radiation therapy treatment planning. MET-PET could not only provide precise visualization of infiltrating tumor cells but also predict the required radiation doses to control target regions.

  6. PET/CT-guided Interventions: Personnel Radiation Dose

    SciTech Connect

    Ryan, E. Ronan Thornton, Raymond; Sofocleous, Constantinos T.; Erinjeri, Joseph P.; Hsu, Meier; Quinn, Brian; Dauer, Lawrence T.; Solomon, Stephen B.

    2013-08-01

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

  7. Monte Carlo dose enhancement studies in microbeam radiation therapy

    SciTech Connect

    Martinez-Rovira, I.; Prezado, Y.

    2011-07-15

    Purpose: A radical radiation therapy treatment for gliomas requires extremely high absorbed doses resulting in subsequent deleterious side effects in healthy tissue. Microbeam radiation therapy (MRT) is an innovative technique based on the fact that normal tissue can withstand high radiation doses in small volumes without any significant damage. The synchrotron-generated x-ray beam is collimated and delivered to an array of narrow micrometer-sized planar rectangular fields. Several preclinical experiments performed at the Brookhaven National Laboratory (BNL) and at the European Synchrotron Radiation Facility (ESRF) confirmed that MRT yields a higher therapeutic index than nonsegmented beams of the same characteristics. This index can be greatly improved by loading the tumor with high atomic number (Z) contrast agents. The aim of this work is to find the high-Z element that provides optimum dose enhancement. Methods: Monte Carlo simulations (PENELOPE/penEasy) were performed to assess the peak and valley doses as well as their ratio (PVDR) in healthy tissue and in the tumor, loaded with different contrast agents. The optimization criteria used were maximization of the ratio between the PVDR values in healthy tissue respect to the PVDR in the tumor and minimization of bone and brain valley doses. Results: Dose enhancement factors, PVDR, and valley doses were calculated for different high-Z elements. A significant decrease of PVDR values in the tumor, accompanied by a gain in the valley doses, was found in the presence of high-Z elements. This enables the deposited dose in the healthy tissue to be reduced. The optimum high-Z element depends on the irradiation configuration. As a general trend, the best outcome is provided by the highest Z contrast agents considered, i.e., gold and thallium. However, lanthanides (especially Lu) and hafnium also offer a satisfactory performance. Conclusions: The remarkable therapeutic index in microbeam radiation therapy can be further

  8. Comparative transcriptome analysis of rice seedlings induced by different doses of heavy ion radiation

    NASA Astrophysics Data System (ADS)

    Zhao, Qian; Sun, Yeqing; Wang, Wei

    2016-07-01

    Highly ionizing radiation (HZE) in space is considered as a main factor causing biological effects on plant seeds. To investigate the different effects on genome-wide gene expression of low-dose and high-dose ion radiation, we carried out ground-base carbon particle HZE experiments with different cumulative doses (0Gy, 0.2Gy, 2Gy) to rice seeds and then performed comparative transcriptome analysis of the rice seedlings. We identified a total of 2551 and 1464 differentially expressed genes (DEGs) in low-dose and high-dose radiation groups, respectively. Gene ontology analyses indicated that low-dose and high-dose ion radiation both led to multiple physiological and biochemical activities changes in rice. By Gene Ontology analyses, the results showed that only one process-oxidation reduction process was enriched in the biological process category after high-dose ion radiation, while more processes such as response to biotic stimulus, heme binding, tetrapyrrole binding, oxidoreductase activity, catalytic activity and oxidoreductase activity were significantly enriched after low-dose ion radiation. The results indicated that the rice plants only focused on the process of oxidation reduction to response to high-dose ion radiation, whereas it was a coordination of multiple biological processes to response to low-dose ion radiation. To elucidate the transcriptional regulation of radiation stress-responsive genes, we identified several DEGs-encoding TFs. AP2/EREBP, bHLH, C2H2, MYB and WRKY TF families were altered significantly in response to ion radiation. Mapman analysis speculated that the biological effects on rice seedlings caused by the radiation stress might share similar mechanisms with the biotic stress. Our findings highlight important alterations in the expression of radiation response genes, metabolic pathways, and TF-encoding genes in rice seedlings exposed to low-dose and high-dose ion radiation.

  9. Modeling Dose-response at Low Dose: A Systems Biology Approach for Ionization Radiation.

    PubMed

    Zhao, Yuchao; Ricci, Paolo F

    2010-03-18

    For ionization radiation (IR) induced cancer, a linear non-threshold (LNT) model at very low doses is the default used by a number of national and international organizations and in regulatory law. This default denies any positive benefit from any level of exposure. However, experimental observations and theoretical biology have found that both linear and J-shaped IR dose-response curves can exist at those very low doses. We develop low dose J-shaped dose-response, based on systems biology, and thus justify its use regarding exposure to IR. This approach incorporates detailed, molecular and cellular descriptions of biological/toxicological mechanisms to develop a dose-response model through a set of nonlinear, differential equations describing the signaling pathways and biochemical mechanisms of cell cycle checkpoint, apoptosis, and tumor incidence due to IR. This approach yields a J-shaped dose response curve while showing where LNT behaviors are likely to occur. The results confirm the hypothesis of the J-shaped dose response curve: the main reason is that, at low-doses of IR, cells stimulate protective systems through a longer cell arrest time per unit of IR dose. We suggest that the policy implications of this approach are an increasingly correct way to deal with precautionary measures in public health.

  10. PET/CT-guided interventions: personnel radiation dose.

    PubMed

    Ryan, E Ronan; Thornton, Raymond; Sofocleous, Constantinos T; Erinjeri, Joseph P; Hsu, Meier; Quinn, Brian; Dauer, Lawrence T; Solomon, Stephen B

    2013-08-01

    To quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures. In this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound). The median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremity dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06). The operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.

  11. Measurement of 226Ra, 232Th, 137Cs and 40K activities of Wheat and Corn Products in Ilam Province – Iran and Resultant Annual Ingestion Radiation Dose

    PubMed Central

    CHANGIZI, Vahid; SHAFIEI, Elham; ZAREH, Mohammad Reza

    2013-01-01

    Background: Background: Natural background radiation is the main source of human exposure to radioactive material. Soils naturally have radioactive mineral contents. The aim of this study is to determine natural (238 U, 232 Th, 40 K) and artificial (137 Cs) radioactivity levels in wheat and corn fields of Eilam province. Methods: HPGe detector was used to measure the concentration activity of 238 U and 232 Th series, 40 K and 137 Cs in wheat and corn samples taken from different regions of Eilam province, in Iran. Results: In wheat and corn samples, the average activity concentrations of 226 Ra, 232 Th, 40 K and 137 Cs were found to be 1, 67, 0.5, 91.73, 0.01 and 0.81, 0.85, 101.52, 0.07 Bq/kg (dry weight), respectively. H ex and H in in the present work are lower than 1. The average value of H ex was found to be 0.02 and 0.025 and average value of H in to be found 0.025 and 0.027 in wheat fields samples and corn samples in Eilam provinces, respectively. The obtained values of AGDE are 30.49 mSv/yr for wheat filed samples and 37.89 mSv/yr for corn samples; the AEDE rate values are 5.28 mSv/yr in wheat filed samples and this average value was found to be 6.13 mSv/yr in corn samples in Eilam. Transfer factors (TFs) of long lived radionuclide such as 137 Cs, 226 Ra, 232 Th and 40 K from soils to corn and wheat plants have been studied by radiotracer experiments. Conclusion: The natural radioactivity levels in Eilam province are not at the range of high risk of morbidity and are under international standards. PMID:26056646

  12. Radiation Dose Estimation for Pediatric Patients Undergoing Cardiac Catheterization

    NASA Astrophysics Data System (ADS)

    Wang, Chu

    Patients undergoing cardiac catheterization are potentially at risk of radiation-induced health effects from the interventional fluoroscopic X-ray imaging used throughout the clinical procedure. The amount of radiation exposure is highly dependent on the complexity of the procedure and the level of optimization in imaging parameters applied by the clinician. For cardiac catheterization, patient radiation dosimetry, for key organs as well as whole-body effective, is challenging due to the lack of fixed imaging protocols, unlike other common X-ray based imaging modalities. Pediatric patients are at a greater risk compared to adults due to their greater cellular radio-sensitivities as well as longer remaining life-expectancy following the radiation exposure. In terms of radiation dosimetry, they are often more challenging due to greater variation in body size, which often triggers a wider range of imaging parameters in modern imaging systems with automatic dose rate modulation. The overall objective of this dissertation was to develop a comprehensive method of radiation dose estimation for pediatric patients undergoing cardiac catheterization. In this dissertation, the research is divided into two main parts: the Physics Component and the Clinical Component. A proof-of-principle study focused on two patient age groups (Newborn and Five-year-old), one popular biplane imaging system, and the clinical practice of two pediatric cardiologists at one large academic medical center. The Physics Component includes experiments relevant to the physical measurement of patient organ dose using high-sensitivity MOSFET dosimeters placed in anthropomorphic pediatric phantoms. First, the three-dimensional angular dependence of MOSFET detectors in scatter medium under fluoroscopic irradiation was characterized. A custom-made spherical scatter phantom was used to measure response variations in three-dimensional angular orientations. The results were to be used as angular dependence

  13. Radiation doses from computed tomography practice in Johor Bahru, Malaysia

    NASA Astrophysics Data System (ADS)

    Karim, M. K. A.; Hashim, S.; Bradley, D. A.; Bakar, K. A.; Haron, M. R.; Kayun, Z.

    2016-04-01

    Radiation doses for Computed Tomography (CT) procedures have been reported, encompassing a total of 376 CT examinations conducted in one oncology centre (Hospital Sultan Ismail) and three diagnostic imaging departments (Hospital Sultanah Aminah, Hospital Permai and Hospital Sultan Ismail) at Johor hospital's. In each case, dose evaluations were supported by data from patient questionnaires. Each CT examination and radiation doses were verified using the CT EXPO (Ver. 2.3.1, Germany) simulation software. Results are presented in terms of the weighted computed tomography dose index (CTDIw), dose length product (DLP) and effective dose (E). The mean values of CTDIw, DLP and E were ranged between 7.6±0.1 to 64.8±16.5 mGy, 170.2±79.2 to 943.3±202.3 mGy cm and 1.6±0.7 to 11.2±6.5 mSv, respectively. Optimization techniques in CT are suggested to remain necessary, with well-trained radiology personnel remaining at the forefront of such efforts.

  14. Variations of the radiation dose onboard Mir station.

    PubMed

    Panasyuk, M I; Teltsov, M V; Shumshurov, V I; Tsetlin, V V

    1998-01-01

    Dose variations, associated with the 11-year solar activity cycle, seasonal variations of particle fluxes in the Earth's radiation belts at the station orbit, and solar proton events are studied, using prolonged measurements of radiation doses inside orbital station Mir. Daily averages of radiation doses during the declining phase of the 22nd solar cycle and during transition to the 23rd solar activity cycle reached very large values for astronauts and significantly exceed the values calculated according to existing models.

  15. Radiation-Induced Leukemia at Doses Relevant to Radiation Therapy: Modeling Mechanisms and Estimating Risks

    NASA Technical Reports Server (NTRS)

    Shuryak, Igor; Sachs, Rainer K.; Hlatky, Lynn; Mark P. Little; Hahnfeldt, Philip; Brenner, David J.

    2006-01-01

    Because many cancer patients are diagnosed earlier and live longer than in the past, second cancers induced by radiation therapy have become a clinically significant issue. An earlier biologically based model that was designed to estimate risks of high-dose radiation induced solid cancers included initiation of stem cells to a premalignant state, inactivation of stem cells at high radiation doses, and proliferation of stem cells during cellular repopulation after inactivation. This earlier model predicted the risks of solid tumors induced by radiation therapy but overestimated the corresponding leukemia risks. Methods: To extend the model to radiation-induced leukemias, we analyzed in addition to cellular initiation, inactivation, and proliferation a repopulation mechanism specific to the hematopoietic system: long-range migration through the blood stream of hematopoietic stem cells (HSCs) from distant locations. Parameters for the model were derived from HSC biologic data in the literature and from leukemia risks among atomic bomb survivors v^ ho were subjected to much lower radiation doses. Results: Proliferating HSCs that migrate from sites distant from the high-dose region include few preleukemic HSCs, thus decreasing the high-dose leukemia risk. The extended model for leukemia provides risk estimates that are consistent with epidemiologic data for leukemia risk associated with radiation therapy over a wide dose range. For example, when applied to an earlier case-control study of 110000 women undergoing radiotherapy for uterine cancer, the model predicted an excess relative risk (ERR) of 1.9 for leukemia among women who received a large inhomogeneous fractionated external beam dose to the bone marrow (mean = 14.9 Gy), consistent with the measured ERR (2.0, 95% confidence interval [CI] = 0.2 to 6.4; from 3.6 cases expected and 11 cases observed). As a corresponding example for brachytherapy, the predicted ERR of 0.80 among women who received an inhomogeneous low-dose

  16. Radiation-Induced Leukemia at Doses Relevant to Radiation Therapy: Modeling Mechanisms and Estimating Risks

    NASA Technical Reports Server (NTRS)

    Shuryak, Igor; Sachs, Rainer K.; Hlatky, Lynn; Mark P. Little; Hahnfeldt, Philip; Brenner, David J.

    2006-01-01

    Because many cancer patients are diagnosed earlier and live longer than in the past, second cancers induced by radiation therapy have become a clinically significant issue. An earlier biologically based model that was designed to estimate risks of high-dose radiation induced solid cancers included initiation of stem cells to a premalignant state, inactivation of stem cells at high radiation doses, and proliferation of stem cells during cellular repopulation after inactivation. This earlier model predicted the risks of solid tumors induced by radiation therapy but overestimated the corresponding leukemia risks. Methods: To extend the model to radiation-induced leukemias, we analyzed in addition to cellular initiation, inactivation, and proliferation a repopulation mechanism specific to the hematopoietic system: long-range migration through the blood stream of hematopoietic stem cells (HSCs) from distant locations. Parameters for the model were derived from HSC biologic data in the literature and from leukemia risks among atomic bomb survivors v^ ho were subjected to much lower radiation doses. Results: Proliferating HSCs that migrate from sites distant from the high-dose region include few preleukemic HSCs, thus decreasing the high-dose leukemia risk. The extended model for leukemia provides risk estimates that are consistent with epidemiologic data for leukemia risk associated with radiation therapy over a wide dose range. For example, when applied to an earlier case-control study of 110000 women undergoing radiotherapy for uterine cancer, the model predicted an excess relative risk (ERR) of 1.9 for leukemia among women who received a large inhomogeneous fractionated external beam dose to the bone marrow (mean = 14.9 Gy), consistent with the measured ERR (2.0, 95% confidence interval [CI] = 0.2 to 6.4; from 3.6 cases expected and 11 cases observed). As a corresponding example for brachytherapy, the predicted ERR of 0.80 among women who received an inhomogeneous low-dose

  17. Measurement and assessment of radiation dose of astronauts in space

    NASA Astrophysics Data System (ADS)

    Zhang, Binquan; Sun, Yue-qiang; Yang, Chuibai; Zhang, Shenyi; Liang, Jinbao

    Astronauts in flight are exposed by the space radiation, which is mainly composed of proton, electron, heavy ion, and neutron. To assess the radiation risk, measurement and assessment of radiation dose of astronauts is indispensable. Especially, measurement for heavy ion radiation is most important as it contributes the major dose. Until now, most of the measurements and assessments of radiation dose of astronauts are based on the LET (Linear Energy Transfer) spectrum of space radiation. However, according to the ICRP Publication 123, energy and charge number of heavy ions should be measured in order to assess space radiation exposure to astronauts. In addition, from the publication, quality factors for each organs or tissues of astronauts are different and they should be calculated or measured independently. Here, a method to measure the energy and charge number of heavy ion and a voxel phantom based on the anatomy of Chinese adult male are presented for radiation dose assessment of astronauts.

  18. APS undulator radiation: First results

    SciTech Connect

    Cai, Z.; Dejus, R.J.; Hartog, P.D.

    1995-12-31

    The first undulator radiation has been extracted from the Advanced Photon Source (APS). The results from the characterization of this radiation are very satisfactory. With the undulator set at a gap of 15.8 mm (K=1.61), harmonics as high as the 17th were observed using a crystal spectrometer. The angular distribution of the third-harmonic radiation was measured, and the source was imaged using a zone plate to determine the particle beam emittance. The horizontal beam emittance was found to be 6.9 {plus_minus} 1.0 nm-rad, and the vertical emittance coupling was found to be less than 3%. The absolute spectral flux was measured over a wide range of photon energies, and it agrees remarkably well with the theoretical calculations based on the measured undulator magnetic field profile and the measured beam emittance. These results indicate that both the emittance of the electron beam and the undulator magnetic field quality exceed the original specifications.

  19. Risk of cancer subsequent to low-dose radiation

    SciTech Connect

    Warren, S.

    1980-01-01

    The author puts low dose irradiation risks in perspective using average background radiation doses for standards. He assailed irresponsible media coverage during the height of public interest in the Three-Mile Island Reactor incident. (PCS)

  20. Contribution of maternal radionuclide burdens to prenatal radiation doses

    SciTech Connect

    Sikov, M.R.; Hui, T.E.

    1996-05-01

    This report describes approaches to calculating and expressing radiation doses to the embryo/fetus from internal radionuclides. Information was obtained for selected, occupationally significant radioelements that provide a spectrum of metabolic and dosimetric characteristics. Evaluations are also presented for inhaled inert gases and for selected radiopharmaceuticals. Fractional placental transfer and/or ratios of concentration in the embryo/fetus to that in the woman were calculated for these materials. The ratios were integrated with data from biokinetic transfer models to estimate radioactivity levels in the embryo/fetus as a function of stage of pregnancy and time after entry into the transfer compartment or blood of the pregnant woman. These results are given as tables of deposition and retention in the embryo/fetus as a function of gestational age at exposure and elapsed time following exposure. Methodologies described by MIRD were extended to formalize and describe details for calculating radiation absorbed doses to the embryo/fetus. Calculations were performed using a model situation that assumed a single injection of 1 {mu}Ci into a woman`s blood; independent calculations were performed for administration at successive months of pregnancy. Gestational -stage-dependent dosimetric tabulations are given together with tables of correlations and relationships. Generalized surrogate dose factors and categorizations are provided in the report to provide for use in operational radiological protection situations. These approaches to calculation yield radiation absorbed doses that can be converted to dose equivalent by multiplication by quality factor. Dose equivalent is the most common quantity for stating prenatal dose limits in the United States and is appropriate for the types of effect that are usually associated with prenatal exposure. If it is desired to obtain alternatives for other purposes, this value can be multiplied by appropriate weighting factors.

  1. Low dose ionizing radiation detection using conjugated polymers

    SciTech Connect

    Silva, E.A.B.; Borin, J.F.; Nicolucci, P.; Graeff, C.F.O.; Netto, T. Ghilardi; Bianchi, R.F.

    2005-03-28

    In this work, the effect of gamma radiation on the optical properties of poly[2-methoxy-5-(2{sup '}-ethylhexyloxy)-p-phenylenevinylene] (MEH-PPV) is studied. The samples were irradiated at room temperature with different doses from 0 Gy to 152 Gy using a {sup 60}Co gamma ray source. For thin films, significant changes in the UV-visible spectra were only observed at high doses (>1 kGy). In solution, shifts in absorption peaks are observed at low doses (<10 Gy), linearly dependent on dose. The shifts are explained by conjugation reduction, and possible causes are discussed. Our results indicate that MEH-PPV solution can be used as a dosimeter adequate for medical applications.

  2. Increased occupational radiation doses: nuclear fuel cycle.

    PubMed

    Bouville, André; Kryuchkov, Victor

    2014-02-01

    The increased occupational doses resulting from the Chernobyl nuclear reactor accident that occurred in Ukraine in April 1986, the reactor accident of Fukushima that took place in Japan in March 2011, and the early operations of the Mayak Production Association in Russia in the 1940s and 1950s are presented and discussed. For comparison purposes, the occupational doses due to the other two major reactor accidents (Windscale in the United Kingdom in 1957 and Three Mile Island in the United States in 1979) and to the main plutonium-producing facility in the United States (Hanford Works) are also covered but in less detail. Both for the Chernobyl nuclear reactor accident and the routine operations at Mayak, the considerable efforts made to reconstruct individual doses from external irradiation to a large number of workers revealed that the recorded doses had been overestimated by a factor of about two.Introduction of Increased Occupational Exposures: Nuclear Industry Workers. (Video 1:32, http://links.lww.com/HP/A21).

  3. Monitoring of radiation dose rates around a clinical nuclear medicine site

    NASA Astrophysics Data System (ADS)

    Shao, Chia-Ho; Lu, Cheng-Chang; Chen, Tou-Rong; Weng, Jui-Hung; Kao, Pan-Fu; Dong, Shang-Lung; Chou, Ming-Jen

    2014-11-01

    The monitoring of radiation dose around the nuclear medicine site is an important study issue. In this study, TLD-100H radiation dosimeters were used to measure the ambient radiation dose rates around a clinical nuclear medicine site in order to investigate the latent hot zones of radiation exposure. Results of this study showed that the radiation doses measured from all piping and storage systems were comparable to the background dose. A relatively high dose was observed at the single bend point of waste water piping of the PET/CT. Another important finding was the unexpected high dose rates observed at the non-restricted waiting area (NRWA) of SPECT. To conclude, this study provides useful information for further determination of an appropriate dose reduction strategy to achieve the ALARA principle in a clinical nuclear medicine site.

  4. Radiation dose in computed tomography of the chest.

    PubMed

    Tack, D; Gevenois, P A

    2004-01-01

    Since the beginning of the eighties, computed tomography (CT) has been more and more widely used as this technique provides precise anatomical details on the lungs, the mediastinum, and the chest wall. However, CT requires the use of ionizing radiations. The collective radiation from CT is therefore in constant increase. As evaluated on atomic bomb survivors, ionizing radiations increase the mortality by cancer. The risk is proportional to the dose and the dose related to CT is much higher than that related to a chest radiograph, both being in the field "of low-level radiations" a range of radiation dose from which no increase in cancer mortality could be demonstrated. This article outlines the risk estimation in the field of low-level radiations, the various methods to measure and estimate the radiation dose, the CT parameters influencing the radiation dose, dose comparisons between CT and most other imaging techniques of the chest, the newly developed so called "Low-Dose" CT techniques and highlights some of the unresolved questions related to radiation dose in clinical CT practice.

  5. Low-dose or low-dose-rate ionizing radiation-induced bioeffects in animal models.

    PubMed

    Tang, Feng Ru; Loke, Weng Keong; Khoo, Boo Cheong

    2017-03-01

    Animal experimental studies indicate that acute or chronic low-dose ionizing radiation (LDIR) (≤100 mSv) or low-dose-rate ionizing radiation (LDRIR) (<6 mSv/h) exposures may be harmful. It induces genetic and epigenetic changes and is associated with a range of physiological disturbances that includes altered immune system, abnormal brain development with resultant cognitive impairment, cataractogenesis, abnormal embryonic development, circulatory diseases, weight gain, premature menopause in female animals, tumorigenesis and shortened lifespan. Paternal or prenatal LDIR/LDRIR exposure is associated with reduced fertility and number of live fetuses, and transgenerational genomic aberrations. On the other hand, in some experimental studies, LDIR/LDRIR exposure has also been reported to bring about beneficial effects such as reduction in tumorigenesis, prolonged lifespan and enhanced fertility. The differences in reported effects of LDIR/LDRIR exposure are dependent on animal genetic background (susceptibility), age (prenatal or postnatal days), sex, nature of radiation exposure (i.e. acute, fractionated or chronic radiation exposure), type of radiation, combination of radiation with other toxic agents (such as smoking, pesticides or other chemical toxins) or animal experimental designs. In this review paper, we aimed to update radiation researchers and radiologists on the current progress achieved in understanding the LDIR/LDRIR-induced bionegative and biopositive effects reported in the various animal models. The roles played by a variety of molecules that are implicated in LDIR/LDRIR-induced health effects will be elaborated. The review will help in future investigations of LDIR/LDRIR-induced health effects by providing clues for designing improved animal research models in order to clarify the current controversial/contradictory findings from existing studies. © The Author 2017. Published by Oxford University Press on behalf of The Japan Radiation Research

  6. Radiation absorbed dose estimates for 18F-BPA PET.

    PubMed

    Kono, Yuzuru; Kurihara, Hiroaki; Kawamoto, Hiroshi; Yasui, Naoko; Honda, Naoki; Igaki, Hiroshi; Itami, Jun

    2017-01-01

    Background Boron neutron capture therapy (BNCT) is a molecular radiation therapy approach based on the (10)B (n, α) (7)Li nuclear reaction in cancer cells. In BNCT, delivery of (10)B in the form of 4-borono-phenylalanine conjugated with fructose (BPA-fr) to the cancer cells is important. The PET tracer 4-borono-2-18F-fluoro-phenylalanine (FBPA) has been used to predict the accumulation of BPA-fr before BNCT. Purpose To determine the biodistribution and dosimetric parameters in 18F-BPA PET/CT studies. Material and Methods Human biokinetic data were obtained during clinical 18F-BPA PET studies between February and June 2015 at one institution. Nine consecutive patients were studied prospectively. The internal radiation dose was calculated on the basis of radioactivity data from blood, urine, and normal tissue of the heart, liver, spleen, kidney, and other parts of the body at each time point using OLINDA/EXM1.1 program. We compared our calculations with published 18F-FDG data. Results Adult patients (3 men, 3 women; age range, 28-68 years) had significantly smaller absorbed doses than pediatric patients (3 patients; age range, 5-12 years) ( P = 0.003). The mean effective dose was 57% lower in adult patients compared with pediatric patients. Mean effective doses for 18F-BPA were 25% lower than those for 18F-FDG presented in International Commission of Radiation Protection (ICRP) publication 106. Conclusion We found significant differences in organ absorbed doses for 18F-BPA against those for 18F-FDG presented in ICRP publication 106. Mean effective doses for 18F-BPA were smaller than those for 18F-FDG in the publication by 0.5-38% (mean difference, 25%).

  7. Strategies to reduce radiation dose in cardiac PET/CT

    NASA Astrophysics Data System (ADS)

    Wu, Tung Hsin; Wu, Nien-Yun; Wang, Shyh-Jen; Wu, Jay; S. P. Mok, Greta; Yang, Ching-Ching; Huang, Tzung-Chi

    2011-08-01

    Our aim was to investigate CT dose reduction strategies on a hybrid PET/CT scanner for cardiac applications.MaterialsImage quality and dose estimation of different CT scanning protocols for CT coronary angiography (CTCA), and CT-based attenuation correction for PET imaging were investigated. Fifteen patients underwent CTCA, perfusion PET imaging at rest and under stress, and FDG PET for myocardial viability. These patients were divided into three groups based on the CTCA technique performed: retrospectively gated helical (RGH), ECG tube current modulation (ETCM), and prospective gated axial (PGA) acquisitions. All emission images were corrected for photon attenuation using CT images obtained by default setting and an ultra-low dose CT (ULDCT) scan.ResultsRadiation dose in RGH technique was 22.2±4.0 mSv. It was reduced to 10.95±0.82 and 4.13±0.31 mSv using ETCM and PGA techniques, respectively. Radiation dose in CT transmission scan was reduced by 96.5% (from 4.53±0.5 to 0.16±0.01 mSv) when applying ULDCT as compared to the default CT. No significant difference in terms of image quality was found among various protocols.ConclusionThe proposed CT scanning strategies, i.e. ETCM or PGA for CTCA and ULDCT for PET attenuation correction, could reduce radiation dose up to 47% without degrading imaging quality in an integrated cardiac PET/CT coronary artery examination.

  8. The Inhibitory Effects of Low-Dose Ionizing Radiation in IgE-Mediated Allergic Responses

    PubMed Central

    Nam, Seon Young; Yang, Kwang Hee; Kim, Cha Soon; Lee, In Kyung; Kim, Ji Young

    2015-01-01

    Ionizing radiation has different biological effects according to dose and dose rate. In particular, the biological effect of low-dose radiation is unclear. Low-dose whole-body gamma irradiation activates immune responses in several ways. However, the effects and mechanism of low-dose radiation on allergic responses remain poorly understood. Previously, we reported that low-dose ionizing radiation inhibits mediator release in IgE-mediated RBL-2H3 mast cell activation. In this study, to have any physiological relevance, we investigated whether low-dose radiation inhibits allergic responses in activated human mast cells (HMC-1(5C6) and LAD2 cells), mouse models of passive cutaneous anaphylaxis and the late-phase cutaneous response. High-dose radiation induced cell death, but low-dose ionizing radiation of <0.5 Gy did not induce mast cell death. Low-dose ionizing radiation that did not induce cell death significantly suppressed mediator release from human mast cells (HMC-1(5C6) and LAD2 cells) that were activated by antigen-antibody reaction. To determine the inhibitory mechanism of mediator released by low-dose ionizing radiation, we examined the phosphorylation of intracellular signaling molecules such as Lyn, Syk, phospholipase Cγ, and protein kinase C, as well as the intracellular free Ca2+ concentration ([Ca2+]i). The phosphorylation of signaling molecules and [Ca2+]i following stimulation of FcεRI receptors was inhibited by low dose ionizing radiation. In agreement with its in vitro effect, ionizing radiation also significantly inhibited inflammatory cells infiltration, cytokine mRNA expression (TNF-α, IL-4, IL-13), and symptoms of passive cutaneous anaphylaxis reaction and the late-phase cutaneous response in anti-dinitrophenyl IgE-sensitized mice. These results indicate that ionizing radiation inhibits both mast cell-mediated immediate- and delayed-type allergic reactions in vivo and in vitro. PMID:26317642

  9. The Inhibitory Effects of Low-Dose Ionizing Radiation in IgE-Mediated Allergic Responses.

    PubMed

    Joo, Hae Mi; Kang, Su Jin; Nam, Seon Young; Yang, Kwang Hee; Kim, Cha Soon; Lee, In Kyung; Kim, Ji Young

    2015-01-01

    Ionizing radiation has different biological effects according to dose and dose rate. In particular, the biological effect of low-dose radiation is unclear. Low-dose whole-body gamma irradiation activates immune responses in several ways. However, the effects and mechanism of low-dose radiation on allergic responses remain poorly understood. Previously, we reported that low-dose ionizing radiation inhibits mediator release in IgE-mediated RBL-2H3 mast cell activation. In this study, to have any physiological relevance, we investigated whether low-dose radiation inhibits allergic responses in activated human mast cells (HMC-1(5C6) and LAD2 cells), mouse models of passive cutaneous anaphylaxis and the late-phase cutaneous response. High-dose radiation induced cell death, but low-dose ionizing radiation of <0.5 Gy did not induce mast cell death. Low-dose ionizing radiation that did not induce cell death significantly suppressed mediator release from human mast cells (HMC-1(5C6) and LAD2 cells) that were activated by antigen-antibody reaction. To determine the inhibitory mechanism of mediator released by low-dose ionizing radiation, we examined the phosphorylation of intracellular signaling molecules such as Lyn, Syk, phospholipase Cγ, and protein kinase C, as well as the intracellular free Ca2+ concentration ([Ca2+]i). The phosphorylation of signaling molecules and [Ca2+]i following stimulation of FcεRI receptors was inhibited by low dose ionizing radiation. In agreement with its in vitro effect, ionizing radiation also significantly inhibited inflammatory cells infiltration, cytokine mRNA expression (TNF-α, IL-4, IL-13), and symptoms of passive cutaneous anaphylaxis reaction and the late-phase cutaneous response in anti-dinitrophenyl IgE-sensitized mice. These results indicate that ionizing radiation inhibits both mast cell-mediated immediate- and delayed-type allergic reactions in vivo and in vitro.

  10. CARCINOGENIC EFFECTS OF LOW DOSES OF IONIZING RADIATION

    EPA Science Inventory

    Carcinogenic Effects of Low Doses of Ionizing Radiation

    R Julian Preston, Environmental Carcinogenesis Division, NHEERL, U.S. Environmental Protection Agency, Research Triangle Park, NC 27711

    The form of the dose-response curve for radiation-induced cancers, particu...

  11. CARCINOGENIC EFFECTS OF LOW DOSES OF IONIZING RADIATION

    EPA Science Inventory

    Carcinogenic Effects of Low Doses of Ionizing Radiation

    R Julian Preston, Environmental Carcinogenesis Division, NHEERL, U.S. Environmental Protection Agency, Research Triangle Park, NC 27711

    The form of the dose-response curve for radiation-induced cancers, particu...

  12. Biological-Based Modeling of Low Dose Radiation Risks

    SciTech Connect

    Scott, Bobby R., Ph.D.

    2006-11-08

    The objective of this project was to refine a biological-based model (called NEOTRANS2) for low-dose, radiation-induced stochastic effects taking into consideration newly available data, including data on bystander effects (deleterious and protective). The initial refinement led to our NEOTRANS3 model which has undergone further refinement (e.g., to allow for differential DNA repair/apoptosis over different dose regions). The model has been successfully used to explain nonlinear dose-response curves for low-linear-energy-transfer (LET) radiation-induced mutations (in vivo) and neoplastic transformation (in vitro). Relative risk dose-response functions developed for neoplastic transformation have been adapted for application to cancer relative risk evaluation for irradiated humans. Our low-dose research along with that conducted by others collectively demonstrate the following regarding induced protection associated with exposure to low doses of low-LET radiation: (1) protects against cell killing by high-LET alpha particles; (2) protects against spontaneous chromosomal damage; (3) protects against spontaneous mutations and neoplastic transformations; (4) suppresses mutations induced by a large radiation dose even when the low dose is given after the large dose; (5) suppresses spontaneous and alpha-radiation-induced cancers; (6) suppresses metastasis of existing cancer; (7) extends tumor latent period; (8) protects against diseases other than cancer; and (9) extends life expectancy. These forms of radiation-induced protection are called adapted protection as they relate to induced adaptive response. Thus, low doses and dose rates of low-LET radiation generally protect rather than harm us. These findings invalidate the linear not threshold (LNT) hypothesis which is based on the premise that any amount of radiation is harmful irrespective of its type. The hypothesis also implicates a linear dose-response curve for cancer induction that has a positive slope and no

  13. Measuring radiation dose to patients undergoing fluoroscopically-guided interventions

    NASA Astrophysics Data System (ADS)

    Lubis, L. E.; Badawy, M. K.

    2016-03-01

    The increasing prevalence and complexity of fluoroscopically guided interventions (FGI) raises concern regarding radiation dose to patients subjected to the procedure. Despite current evidence showing the risk to patients from the deterministic effects of radiation (e.g. skin burns), radiation induced injuries remain commonplace. This review aims to increase the awareness surrounding radiation dose measurement for patients undergoing FGI. A review of the literature was conducted alongside previous researches from the authors’ department. Studies pertaining to patient dose measurement, its formalism along with current advances and present challenges were reviewed. Current patient monitoring techniques (using available radiation dosimeters), as well as the inadequacy of accepting displayed dose as patient radiation dose is discussed. Furthermore, advances in real-time patient radiation dose estimation during FGI are considered. Patient dosimetry in FGI, particularly in real time, remains an ongoing challenge. The increasing occurrence and sophistication of these procedures calls for further advances in the field of patient radiation dose monitoring. Improved measuring techniques will aid clinicians in better predicting and managing radiation induced injury following FGI, thus improving patient care.

  14. Has the use of computers in radiation therapy improved the accuracy in radiation dose delivery?

    NASA Astrophysics Data System (ADS)

    Van Dyk, J.; Battista, J.

    2014-03-01

    Purpose: It is well recognized that computer technology has had a major impact on the practice of radiation oncology. This paper addresses the question as to how these computer advances have specifically impacted the accuracy of radiation dose delivery to the patient. Methods: A review was undertaken of all the key steps in the radiation treatment process ranging from machine calibration to patient treatment verification and irradiation. Using a semi-quantitative scale, each stage in the process was analysed from the point of view of gains in treatment accuracy. Results: Our critical review indicated that computerization related to digital medical imaging (ranging from target volume localization, to treatment planning, to image-guided treatment) has had the most significant impact on the accuracy of radiation treatment. Conversely, the premature adoption of intensity-modulated radiation therapy has actually degraded the accuracy of dose delivery compared to 3-D conformal radiation therapy. While computational power has improved dose calibration accuracy through Monte Carlo simulations of dosimeter response parameters, the overall impact in terms of percent improvement is relatively small compared to the improvements accrued from 3-D/4-D imaging. Conclusions: As a result of computer applications, we are better able to see and track the internal anatomy of the patient before, during and after treatment. This has yielded the most significant enhancement to the knowledge of "in vivo" dose distributions in the patient. Furthermore, a much richer set of 3-D/4-D co-registered dose-image data is thus becoming available for retrospective analysis of radiobiological and clinical responses.

  15. Pacemaker failure resulting from radiation damage

    SciTech Connect

    Quertermous, T.; Megahy, M.S.; Das Gupta, D.S.; Griem, M.L.

    1983-07-01

    The authors present a case of radiation-induced pacemaker failure. After 2000 rad (20 Gy) of photon irradiation for metastatic bronchogenic carcinoma, the pulse generator circuitry failed, producing a runaway rhythm. This suggests that present pacemaker circuitry may be more susceptible to irradiation than previously believed, and that even modest radiation doses can induce life-threatening arrhythmias.

  16. [About Dose-Effect Relationship in the Environment Radiation Protection].

    PubMed

    Udalova, A A

    2015-01-01

    One of the most important stages in the development of a methodology for the environment radiation protection is the assessment and justification of critical radiation exposure levels for ecosystem components. In this study application of the approach for critical dose level estimation is demonstrated on the example of the data about ionizing radiation effect on reproduction and survival of agricultural plants after acute and chronic exposures. Influence of the type of dose-effect relationship on the estimated values of the critical doses and dose rates is studied using three models (linear, logarithmic and logistic). The findings obtained do not provide any robust recommendations in favor of one of the three tested functions. The models of dose-effect relationship (threshold or non-threshold) and types of radiation-induced effects (stochastic and deterministic) are discussed from the viewpoint of developing a system for radiation protection of human and non-human biota.

  17. Radiation dose reduction in multidetector CT in fracture evaluation.

    PubMed

    Yi, Jung Woo; Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Hong, Hyun Pyo; Choi, Yoon Jung; Kim, Mi Sung

    2017-08-01

    To evaluate whether multidetector CT with low-dose radiation (low-dose CT) of joints can be useful when evaluating fractures. Our study included CT scans of 398 patients, 103 shoulder cases, 109 wrist cases, 98 pelvis cases and 88 ankle cases. There were 191 females and 207 males. The low-dose CTs were performed using identical voltage and parameters with the exception of decreased (half of standard dose) tube current. Low-dose and standard-dose images were compared with regards to objective image quality, subjective evaluation of image quality and diagnostic performance for the fractures. There was no significant difference of image noise between standard-dose CT and low-dose CT in every joint (p > 0.05). Each mean value of subjective score did not show significant difference according to the dosage of the CT scan. There were no statistically significant differences in the sensitivity (96-100%), specificity (95.2-100%) or accuracy (97.9-100%) between standard-dose CT and low-dose CT (p values, 0.1336-1.000). The evaluation of extremities for fractures using low-dose CT can reduce radiation exposure by about 50% compared with standard-dose CT without affecting image quality or diagnostic performance. Advances in knowledge: Low-dose CT of the extremities (shoulder, pelvis, ankle and wrist) can reduce radiation dose by about 50% compared with standard-dose CT and does not significantly affect image quality or diagnostic performance in fracture detection.

  18. Radiation leakage dose from Elekta electron collimation system.

    PubMed

    Pitcher, Garrett M; Hogstrom, Kenneth R; Carver, Robert L

    2016-09-08

    This study provided baseline data required for a greater project, whose objective was to design a new Elekta electron collimation system having significantly lighter electron applicators with equally low out-of field leakage dose. Specifically, off-axis dose profiles for the electron collimation system of our uniquely configured Elekta Infinity accelerator with the MLCi2 treatment head were measured and calculated for two primary purposes: 1) to evaluate and document the out-of-field leakage dose in the patient plane and 2) to validate the dose distributions calculated using a BEAMnrc Monte Carlo (MC) model for out-of-field dose profiles. Off-axis dose profiles were measured in a water phantom at 100 cm SSD for 1 and 2 cm depths along the in-plane, cross-plane, and both diagonal axes using a cylindrical ionization chamber with the 10 × 10 and 20 × 20 cm2 applicators and 7, 13, and 20 MeV beams. Dose distributions were calculated using a previously developed BEAMnrc MC model of the Elekta Infinity accelerator for the same beam energies and applicator sizes and compared with measurements. Measured results showed that the in-field beam flatness met our acceptance criteria (± 3% on major and ±4% on diagonal axes) and that out-of-field mean and maximum percent leakage doses in the patient plane met acceptance criteria as specified by the International Electrotechnical Commission (IEC). Cross-plane out-of-field dose profiles showed greater leakage dose than in-plane profiles, attributed to the curved edges of the upper X-ray jaws and multileaf collimator. Mean leakage doses increased with beam energy, being 0.93% and 0.85% of maximum central axis dose for the 10 × 10 and 20 × 20 cm2 applicators, respectively, at 20 MeV. MC calculations predicted the measured dose to within 0.1% in most profiles outside the radiation field; however, excluding model-ing of nontrimmer applicator components led to calculations exceeding measured data by as much as 0.2% for some regions

  19. A Bayesian Semiparametric Model for Radiation Dose-Response Estimation.

    PubMed

    Furukawa, Kyoji; Misumi, Munechika; Cologne, John B; Cullings, Harry M

    2016-06-01

    In evaluating the risk of exposure to health hazards, characterizing the dose-response relationship and estimating acceptable exposure levels are the primary goals. In analyses of health risks associated with exposure to ionizing radiation, while there is a clear agreement that moderate to high radiation doses cause harmful effects in humans, little has been known about the possible biological effects at low doses, for example, below 0.1 Gy, which is the dose range relevant to most radiation exposures of concern today. A conventional approach to radiation dose-response estimation based on simple parametric forms, such as the linear nonthreshold model, can be misleading in evaluating the risk and, in particular, its uncertainty at low doses. As an alternative approach, we consider a Bayesian semiparametric model that has a connected piece-wise-linear dose-response function with prior distributions having an autoregressive structure among the random slope coefficients defined over closely spaced dose categories. With a simulation study and application to analysis of cancer incidence data among Japanese atomic bomb survivors, we show that this approach can produce smooth and flexible dose-response estimation while reasonably handling the risk uncertainty at low doses and elsewhere. With relatively few assumptions and modeling options to be made by the analyst, the method can be particularly useful in assessing risks associated with low-dose radiation exposures.

  20. Non linear processes modulated by low doses of radiation exposure

    NASA Astrophysics Data System (ADS)

    Mariotti, Luca; Ottolenghi, Andrea; Alloni, Daniele; Babini, Gabriele; Morini, Jacopo; Baiocco, Giorgio

    The perturbation induced by radiation impinging on biological targets can stimulate the activation of several different pathways, spanning from the DNA damage processing to intra/extra -cellular signalling. In the mechanistic investigation of radiobiological damage this complex “system” response (e.g. omics, signalling networks, micro-environmental modifications, etc.) has to be taken into account, shifting from a focus on the DNA molecule solely to a systemic/collective view. An additional complication comes from the finding that the individual response of each of the involved processes is often not linear as a function of the dose. In this context, a systems biology approach to investigate the effects of low dose irradiations on intra/extra-cellular signalling will be presented, where low doses of radiation act as a mild perturbation of a robustly interconnected network. Results obtained through a multi-level investigation of both DNA damage repair processes (e.g. gamma-H2AX response) and of the activation kinetics for intra/extra cellular signalling pathways (e.g. NFkB activation) show that the overall cell response is dominated by non-linear processes - such as negative feedbacks - leading to possible non equilibrium steady states and to a poor signal-to-noise ratio. Together with experimental data of radiation perturbed pathways, different modelling approaches will be also discussed.

  1. Low dose radiation damage effects in silicon strip detectors

    NASA Astrophysics Data System (ADS)

    Wiącek, P.; Dąbrowski, W.

    2016-11-01

    The radiation damage effects in silicon segmented detectors caused by X-rays have become recently an important research topic driven mainly by development of new detectors for applications at the European X-ray Free Electron Laser (E-XFEL). However, radiation damage in silicon strip is observed not only after extreme doses up to 1 GGy expected at E-XFEL, but also at doses in the range of tens of Gy, to which the detectors in laboratory instruments like X-ray diffractometers or X-ray spectrometers can be exposed. In this paper we report on investigation of radiation damage effects in a custom developed silicon strip detector used in laboratory diffractometers equipped with X-ray tubes. Our results show that significant degradation of detector performance occurs at low doses, well below 200 Gy, which can be reached during normal operation of laboratory instruments. Degradation of the detector energy resolution can be explained by increasing leakage current and increasing interstrip capacitance of the sensor. Another observed effect caused by accumulation of charge trapped in the surface oxide layer is change of charge division between adjacent strips. In addition, we have observed unexpected anomalies in the annealing process.

  2. Radiation dose to the pediatric cardiac catheterization and intervention patient.

    PubMed

    Chida, Koichi; Ohno, Tadayuki; Kakizaki, Shuhei; Takegawa, Mika; Yuuki, Hiroko; Nakada, Mitsuru; Takahashi, Shoki; Zuguchi, Masayuki

    2010-11-01

    The radiation dose from cardiac catheterization is particularly relevant when treating children because of their greater radiosensitivity compared with adults. Moreover, cardiac catheterization is being used increasingly for interventional radiology procedures, possibly resulting in higher patient radiation doses. This article reports the radiation doses and related factors, such as fluoroscopy time, for children who underwent cardiac catheterization and children who underwent other interventional radiology procedures. We evaluated 239 consecutive patients who underwent cardiac catheterization (n = 205) or another interventional radiology procedure (n = 34) for which the dose-area product (DAP) was measured. The number of cine runs and fluoroscopic time for each procedure and the body mass index and body weight of each patient were recorded. We also used the double product combined with body weight, which is the weight- fluoroscopic time product. The average DAP ± SD of cardiac catheterization and of an interventional radiology procedure was 1,702.6 ± 2,110.1 cGy × cm² and 2,242.2 ± 2,509.4 cGy × cm², respectively. The average fluoroscopic time ± SD of cardiac catheterization and of an interventional radiology procedure was 24.1 ± 16.8 minutes and 37.2 ± 20.0 minutes. For children who underwent cardiac catheterization and those who underwent an interventional radiology procedure, a strong correlation was seen between the DAP and weight-fluoroscopic time product (cardiac catheterization, r = 0.906; interventional radiology procedure, r = 0.885) and a good correlation was detected between the DAP and weight (r = 0.819 and 0.895, respectively). There was a good correlation between the DAP and weight and between DAP and weight-fluoroscopic time product for children who underwent cardiac catheterization or an interventional radiology procedure. Therefore, body weight is important for determining radiation dose to children undergoing cardiac catheterization or

  3. Patient radiation dose audits for fluoroscopically guided interventional procedures

    SciTech Connect

    Balter, Stephen; Rosenstein, Marvin; Miller, Donald L.; Schueler, Beth; Spelic, David

    2011-03-15

    Purpose: Quality management for any use of medical x-ray imaging should include monitoring of radiation dose. Fluoroscopically guided interventional (FGI) procedures are inherently clinically variable and have the potential for inducing deterministic injuries in patients. The use of a conventional diagnostic reference level is not appropriate for FGI procedures. A similar but more detailed quality process for management of radiation dose in FGI procedures is described. Methods: A method that takes into account both the inherent variability of FGI procedures and the risk of deterministic injuries from these procedures is suggested. The substantial radiation dose level (SRDL) is an absolute action level (with regard to patient follow-up) below which skin injury is highly unlikely and above which skin injury is possible. The quality process for FGI procedures collects data from all instances of a given procedure from a number of facilities into an advisory data set (ADS). An individual facility collects a facility data set (FDS) comprised of all instances of the same procedure at that facility. The individual FDS is then compared to the multifacility ADS with regard to the overall shape of the dose distributions and the percent of instances in both the ADS and the FDS that exceed the SRDL. Results: Samples of an ADS and FDS for percutaneous coronary intervention, using the dose metric of reference air kerma (K{sub a,r}) (i.e., the cumulative air kerma at the reference point), are used to illustrate the proposed quality process for FGI procedures. Investigation is warranted whenever the FDS is noticeably different from the ADS for the specific FGI procedure and particularly in two circumstances: (1) When the facility's local median K{sub a,r} exceeds the 75th percentile of the ADS and (2) when the percent of instances where K{sub a,r} exceeds the facility-selected SRDL is greater for the FDS than for the ADS. Conclusions: Analysis of the two data sets (ADS and FDS) and

  4. Ionizing Radiation Dose Due to the Use of Agricultural Fertilizers

    NASA Astrophysics Data System (ADS)

    Umisedo, Nancy K.; Okuno, Emico; Colacioppo, Sérgio; Medina, Nilberto H.; Hiodo, Francisco Y.

    2008-08-01

    The transference of radionuclides from the fertilizers to/and from soils to the foodstuffs can represent an increment in the internal dose when the vegetables are consumed by the human beings. This work evaluates the contribution of fertilizers to the increase of radiation level in the environment and of dose to the people. Samples of fertilizers, soils and vegetables produced in farms located in the neighbourhood of São Paulo city in the State of São Paulo, Brazil were analysed through gamma spectroscopy. The values of specific activity of 40K, 238U and 232Th show that there is no significant transference of natural radionuclides from fertilizers to the final product of the food chain. The annual committed effective dose due to the ingestion of 40K contained in the group of consumed vegetables analysed in this work resulted in the very low value of 0.882 μSv.

  5. Ionizing Radiation Dose Due to the Use of Agricultural Fertilizers

    SciTech Connect

    Umisedo, Nancy K.; Okuno, Emico; Medina, Nilberto H.; Colacioppo, Sergio; Hiodo, Francisco Y.

    2008-08-07

    The transference of radionuclides from the fertilizers to/and from soils to the foodstuffs can represent an increment in the internal dose when the vegetables are consumed by the human beings. This work evaluates the contribution of fertilizers to the increase of radiation level in the environment and of dose to the people. Samples of fertilizers, soils and vegetables produced in farms located in the neighbourhood of Sao Paulo city in the State of Sao Paulo, Brazil were analysed through gamma spectroscopy. The values of specific activity of {sup 40}K, {sup 238}U and {sup 232}Th show that there is no significant transference of natural radionuclides from fertilizers to the final product of the food chain. The annual committed effective dose due to the ingestion of {sup 40}K contained in the group of consumed vegetables analysed in this work resulted in the very low value of 0.882 {mu}Sv.

  6. Effect of radiation energy and intracellular iron dose on iron oxide nanoparticle enhancement of radiation cytotoxicity

    NASA Astrophysics Data System (ADS)

    Mazur, Courtney M.; Strawbridge, Rendall R.; Thompson, Ella S.; Petryk, Alicia A.; Gladstone, David J.; Hoopes, P. Jack

    2015-03-01

    Iron oxide nanoparticles (IONPs) are one of several high-Z materials currently being investigated for their ability to enhance the cytotoxic effects of therapeutic ionizing radiation. Studies with iron oxide, silver, gold, and hafnium oxide suggest radiation dose, radiation energy, cell type, and the type and level of metallic nanoparticle are all critical factors in achieving radiation enhancement in tumor cells. Using a single 4 Gy radiation dose, we compared the level of tumor cell cytotoxicity at two different intracellular iron concentrations and two different radiation energies in vitro. IONPs were added to cell culture media at concentrations of 0.25 mg Fe/mL and 1.0 mg Fe/mL and incubated with murine breast adenocarcinoma (MTG-B) cells for 72 hours. Extracellular iron was then removed and cells were irradiated at either 662 keV or 10 MV. At the 0.25 mg Fe/mL dose (4 pg Fe/cell), radiation energy did not affect the level of cytotoxicity. However with 1.0 mg Fe/mL (9 pg Fe/cell), the higher 10 MV radiation energy resulted in 50% greater cytotoxicity as compared to cells without IONPs irradiated at this energy. These results suggest IONPs may be able to significantly enhance the cytotoxic effects of radiation and improve therapeutic ratio if they can be selectively associated with cancer cells and/or tumors. Ongoing in vivo studies of IONP radiation enhancement in a murine tumor model are too immature to draw conclusions from at this time, however preliminary data suggests similar effectiveness of IONP radiation enhancement at 6 MV and 18 MV energy levels. In addition to the IONP-based radiation enhancement demonstrated here, the use of tumor-localized IONP with an externally delivered, non-toxic alternating magnetic field affords the opportunity to selectively heat and kill tumor cells. Combining IONP-based radiation sensitization and heat-based cytotoxicity provides a unique and potentially highly effective opportunity for therapeutic ratio enhancement.

  7. Radiation Dose Assessments for Shore-Based Individuals in Operation Tomodachi, Revision 1

    DTIC Science & Technology

    2012-12-31

    potentially exposed to radioactive fallout resulting from the Fukushima Daiichi nuclear power station units’ radiological releases that followed the...2012, which will support public inquiries. 15. SUBJECT TERMS Operation Tomodachi, Radiation Dose, Department of Defense, Japan, Fukushima ...external radiation dose monitoring station in Fukushima Prefecture (2.5 meters above ground level

  8. Radiation Dose Assessments for Shore-Based Individuals in Operation Tomodachi

    DTIC Science & Technology

    2012-09-30

    radioactive fallout resulting from the Fukushima Daiichi nuclear power station units’ radiological releases that followed the earthquake and tsunami on March...public inquiries. 15. SUBJECT TERMS Operation Tomodachi, Radiation Dose, Department of Defense, Japan, Fukushima , Earthquake, Tsunami 16...Yokosuka NB ......... 35 Figure 7. MEXT external radiation dose monitoring station in Fukushima Prefecture (2.5 meters above ground level

  9. Radiation dose of CT coronary angiography in clinical practice: objective evaluation of strategies for dose optimization.

    PubMed

    Yerramasu, Ajay; Venuraju, Shreenidhi; Atwal, Satvir; Goodman, Dennis; Lipkin, David; Lahiri, Avijit

    2012-07-01

    CT coronary angiography (CTCA) is an evolving modality for the diagnosis of coronary artery disease. Radiation burden associated with CTCA has been a major concern in the wider application of this technique. It is important to reduce the radiation dose without compromising the image quality. To estimate the radiation dose of CTCA in clinical practice and evaluate the effect of dose-saving algorithms on radiation dose and image quality. Effective radiation dose was measured from the dose-length product in 616 consecutive patients (mean age 58 ± 12 years; 70% males) who underwent clinically indicated CTCA at our institution over 1 year. Image quality was assessed subjectively using a 4-point scale and objectively by measuring the signal- and contrast-to-noise ratios in the coronary arteries. Multivariate linear regression analysis was used to identify factors independently associated with radiation dose. Mean effective radiation dose of CTCA was 6.6 ± 3.3 mSv. Radiation dose was significantly reduced by dose saving algorithms such as 100 kV imaging (-47%; 95% CI, -44% to -50%), prospective gating (-35%; 95% CI, -29% to -40%) and ECG controlled tube current modulation (-23%; 95% CI, -9% to -34%). None of the dose saving algorithms were associated with a significant reduction in mean image quality or the frequency of diagnostic scans (P = non-significant for all comparisons). Careful application of radiation-dose saving algorithms in appropriately selected patients can reduce the radiation burden of CTCA significantly, without compromising the image quality. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  10. Total dose performance of radiation hardened voltage regulators and references

    NASA Technical Reports Server (NTRS)

    McClure, S.; Gorelick, J.; Pease, R.; Rax, B.; Ladbury, R.

    2001-01-01

    Total dose test of commercially available radiation hardened bipolar voltage regulators and references show reduced sensitivity to dose rate and varying sensitivity to bias under pressure. Behavior of critical parameters in different dose rate and bias conditions is compared and the impact to hardness assurance methodology is discussed.

  11. RADIANCE: An automated, enterprise-wide solution for archiving and reporting CT radiation dose estimates.

    PubMed

    Cook, Tessa S; Zimmerman, Stefan L; Steingall, Scott R; Maidment, Andrew D A; Kim, Woojin; Boonn, William W

    2011-01-01

    There is growing interest in the ability to monitor, track, and report exposure to radiation from medical imaging. Historically, however, dose information has been stored on an image-based dose sheet, an arrangement that precludes widespread indexing. Although scanner manufacturers are beginning to include dose-related parameters in the Digital Imaging and Communications in Medicine (DICOM) headers of imaging studies, there remains a vast repository of retrospective computed tomographic (CT) data with image-based dose sheets. Consequently, it is difficult for imaging centers to monitor their dose estimates or participate in the American College of Radiology (ACR) Dose Index Registry. An automated extraction software pipeline known as Radiation Dose Intelligent Analytics for CT Examinations (RADIANCE) has been designed that quickly and accurately parses CT dose sheets to extract and archive dose-related parameters. Optical character recognition of information in the dose sheet leads to creation of a text file, which along with the DICOM study header is parsed to extract dose-related data. The data are then stored in a relational database that can be queried for dose monitoring and report creation. RADIANCE allows efficient dose analysis of CT examinations and more effective education of technologists, radiologists, and referring physicians regarding patient exposure to radiation at CT. RADIANCE also allows compliance with the ACR's dose reporting guidelines and greater awareness of patient radiation dose, ultimately resulting in improved patient care and treatment.

  12. Estimation of Internal Radiation Dose from both Immediate Releases and Continued Exposures to Contaminated Materials

    SciTech Connect

    Napier, Bruce A.

    2012-03-26

    A brief description is provided of the basic concepts related to 'internal dose' and how it differs from doses that result from radioactive materials and direct radiation outside of the body. The principles of radiation dose reconstruction, as applied to both internal and external doses, is discussed based upon a recent publication prepared by the US National Council on Radiation Protection and Measurements. Finally, ideas are introduced related to residual radioactive contamination in the environment that has resulted from the releases from the damaged reactors and also to the management of wastes that may be generated in both regional cleanup and NPP decommissioning.

  13. Radiation dose estimate in small animal SPECT and PET.

    PubMed

    Funk, Tobias; Sun, Mingshan; Hasegawa, Bruce H

    2004-09-01

    Calculations of radiation dose are important in assessing the medical and biological implications of ionizing radiation in medical imaging techniques such as SPECT and PET. In contrast, radiation dose estimates of SPECT and PET imaging of small animals are not very well established. For that reason we have estimated the whole-body radiation dose to mice and rats for isotopes such as 18F, 99mTc, 201Tl, (111)In, 123I, and 125I that are used commonly for small animal imaging. We have approximated mouse and rat bodies with uniform soft tissue equivalent ellipsoids. The mouse and rat sized ellipsoids had a mass of 30 g and 300 g, respectively, and a ratio of the principal axes of 1:1:4 and 0.7:1:4. The absorbed fractions for various photon energies have been calculated using the Monte Carlo software package MCNP. Using these values, we then calculated MIRD S-values for two geometries that model the distribution of activity in the animal body: (a) a central point source and (b) a homogeneously distributed source, and compared these values against S-value calculations for small ellipsoids tabulated in MIRD Pamphlet 8 to validate our results. Finally we calculated the radiation dose taking into account the biological half-life of the radiopharmaceuticals and the amount of activity administered. Our calculations produced S-values between 1.06 x 10(-13) Gy/Bq s and 2.77 x 10(-13) Gy/Bq s for SPECT agents, and 15.0 x 10(-13) Gy/Bq s for the PET agent 18F, assuming mouse sized ellipsoids with uniform source distribution. The S-values for a central point source in an ellipsoid are about 10% higher than the values obtained for the uniform source distribution. Furthermore, the S-values for mouse sized ellipsoids are approximately 10 times higher than for the rat sized ellipsoids reflecting the difference in mass. We reviewed published data to obtain administered radioactivity and residence times for small animal imaging. From these values and our computed S-values we estimated

  14. The Radiation Dose-Response of the Human Spinal Cord

    SciTech Connect

    Schultheiss, Timothy E.

    2008-08-01

    Purpose: To characterize the radiation dose-response of the human spinal cord. Methods and Materials: Because no single institution has sufficient data to establish a dose-response function for the human spinal cord, published reports were combined. Requisite data were dose and fractionation, number of patients at risk, number of myelopathy cases, and survival experience of the population. Eight data points for cervical myelopathy were obtained from five reports. Using maximum likelihood estimation correcting for the survival experience of the population, estimates were obtained for the median tolerance dose, slope parameter, and {alpha}/{beta} ratio in a logistic dose-response function. An adequate fit to thoracic data was not possible. Hyperbaric oxygen treatments involving the cervical cord were also analyzed. Results: The estimate of the median tolerance dose (cervical cord) was 69.4 Gy (95% confidence interval, 66.4-72.6). The {alpha}/{beta} = 0.87 Gy. At 45 Gy, the (extrapolated) probability of myelopathy is 0.03%; and at 50 Gy, 0.2%. The dose for a 5% myelopathy rate is 59.3 Gy. Graphical analysis indicates that the sensitivity of the thoracic cord is less than that of the cervical cord. There appears to be a sensitizing effect from hyperbaric oxygen treatment. Conclusions: The estimate of {alpha}/{beta} is smaller than usually quoted, but values this small were found in some studies. Using {alpha}/{beta} = 0.87 Gy, one would expect a considerable advantage by decreasing the dose/fraction to less than 2 Gy. These results were obtained from only single fractions/day and should not be applied uncritically to hyperfractionation.

  15. Concurrent image and dose reconstruction for image guided radiation therapy

    NASA Astrophysics Data System (ADS)

    Sheng, Ke

    The importance of knowing the patient actual position is essential for intensity modulated radiation therapy (IMRT). This procedure uses tightened margin and escalated tumor dose. In order to eliminate the uncertainty of the geometry in IMRT, daily imaging is prefered. The imaging dose, limited field of view and the imaging concurrency of the MVCT (mega-voltage computerized tomography) are investigated in this work. By applying partial volume imaging (PVI), imaging dose can be reduced for a region of interest (ROI) imaging. The imaging dose and the image quality are quantitatively balanced with inverse imaging dose planning. With PVI, 72% average imaging dose reduction was observed on a typical prostate patient case. The algebraic reconstruction technique (ART) based projection onto convex sets (POCS) shows higher robustness than filtered back projection when available imaging data is not complete and continuous. However, when the projection is continuous as in the actual delivery, a non-iterative wavelet based multiresolution local tomography (WMLT) is able to achieve 1% accuracy within the ROI. The reduction of imaging dose is dependent on the size of ROI. The improvement of concurrency is also discussed based on the combination of PVI and WMLT. Useful target images were acquired with treatment beams and the temporal resolution can be increased to 20 seconds in tomotherapy. The data truncation problem with the portal imager was also studied. Results show that the image quality is not adversely affected by truncation when WMLT is employed. When the online imaging is available, a perturbation dose calculation (PDC) that estimates the actual delivered dose is proposed. Corrected from the Fano's theorem, PDC counts the first order term in the density variation to calculate the internal and external anatomy change. Although change in the dose distribution that is caused by the internal organ motion is less than 1% for 6 MV beams, the external anatomy change has

  16. Cone beam computed tomography radiation dose and image quality assessments.

    PubMed

    Lofthag-Hansen, Sara

    2010-01-01

    Diagnostic radiology has undergone profound changes in the last 30 years. New technologies are available to the dental field, cone beam computed tomography (CBCT) as one of the most important. CBCT is a catch-all term for a technology comprising a variety of machines differing in many respects: patient positioning, volume size (FOV), radiation quality, image capturing and reconstruction, image resolution and radiation dose. When new technology is introduced one must make sure that diagnostic accuracy is better or at least as good as the one it can be expected to replace. The CBCT brand tested was two versions of Accuitomo (Morita, Japan): 3D Accuitomo with an image intensifier as detector, FOV 3 cm x 4 cm and 3D Accuitomo FPD with a flat panel detector, FOVs 4 cm x 4 cm and 6 cm x 6 cm. The 3D Accuitomo was compared with intra-oral radiography for endodontic diagnosis in 35 patients with 46 teeth analyzed, of which 41 were endodontically treated. Three observers assessed the images by consensus. The result showed that CBCT imaging was superior with a higher number of teeth diagnosed with periapical lesions (42 vs 32 teeth). When evaluating 3D Accuitomo examinations in the posterior mandible in 30 patients, visibility of marginal bone crest and mandibular canal, important anatomic structures for implant planning, was high with good observer agreement among seven observers. Radiographic techniques have to be evaluated concerning radiation dose, which requires well-defined and easy-to-use methods. Two methods: CT dose index (CTDI), prevailing method for CT units, and dose-area product (DAP) were evaluated for calculating effective dose (E) for both units. An asymmetric dose distribution was revealed when a clinical situation was simulated. Hence, the CTDI method was not applicable for these units with small FOVs. Based on DAP values from 90 patient examinations effective dose was estimated for three diagnostic tasks: implant planning in posterior mandible and

  17. Radiation doses to insertion devices at the Advanced Photon Source

    SciTech Connect

    Moog, E.R.; Den Hartog, P.K.; Semones, E.J.; Job, P.K.

    1997-09-01

    Dose measurements made on and around the insertion devices (IDs) at the Advanced Photon Source are reported. Attempts are made to compare these dose rates to dose rates that have been reported to cause radiation-induced demagnetization, but comparisons are complicated by such factors as the particular magnet material and the techniques used in its manufacture, the spectrum and type of radiation, and the demagnetizing field seen by the magnet. The spectrum of radiation at the IDs. It has almost no effect on the dose to the downstream ends of the IDs, however, since much of the radiation travels through the ID vacuum chamber and cannot be readily shielded. Opening the gaps of the IDs during injection and at other times also helps decrease the radiation exposure.

  18. The Dose Window for Radiation-Induced Protective Adaptive Responses

    PubMed Central

    Mitchel, Ronald E. J.

    2009-01-01

    Adaptive responses to low doses of low LET radiation occur in all organisms thus far examined, from single cell lower eukaryotes to mammals. These responses reduce the deleterious consequences of DNA damaging events, including radiation-induced or spontaneous cancer and non-cancer diseases in mice. The adaptive response in mammalian cells and mammals operates within a certain window that can be defined by upper and lower dose thresholds, typically between about 1 and 100 mGy for a single low dose rate exposure. However, these thresholds for protection are not a fixed function of total dose, but also vary with dose rate, additional radiation or non-radiation stressors, tissue type and p53 functional status. Exposures above the upper threshold are generally detrimental, while exposures below the lower threshold may or may not increase either cancer or non-cancer disease risk. PMID:20585438

  19. A technique for multi-dimensional optimization of radiation dose, contrast dose, and image quality in CT imaging

    NASA Astrophysics Data System (ADS)

    Sahbaee, Pooyan; Abadi, Ehsan; Sanders, Jeremiah; Becchetti, Marc; Zhang, Yakun; Agasthya, Greeshma; Segars, Paul; Samei, Ehsan

    2016-03-01

    The purpose of this study was to substantiate the interdependency of image quality, radiation dose, and contrast material dose in CT towards the patient-specific optimization of the imaging protocols. The study deployed two phantom platforms. First, a variable sized phantom containing an iodinated insert was imaged on a representative CT scanner at multiple CTDI values. The contrast and noise were measured from the reconstructed images for each phantom diameter. Linearly related to iodine-concentration, contrast to noise ratio (CNR), was calculated for different iodine-concentration levels. Second, the analysis was extended to a recently developed suit of 58 virtual human models (5D-XCAT) with added contrast dynamics. Emulating a contrast-enhanced abdominal image procedure and targeting a peak-enhancement in aorta, each XCAT phantom was "imaged" using a CT simulation platform. 3D surfaces for each patient/size established the relationship between iodine-concentration, dose, and CNR. The Sensitivity of Ratio (SR), defined as ratio of change in iodine-concentration versus dose to yield a constant change in CNR was calculated and compared at high and low radiation dose for both phantom platforms. The results show that sensitivity of CNR to iodine concentration is larger at high radiation dose (up to 73%). The SR results were highly affected by radiation dose metric; CTDI or organ dose. Furthermore, results showed that the presence of contrast material could have a profound impact on optimization results (up to 45%).

  20. Patient radiation doses for electron beam CT

    SciTech Connect

    Castellano, Isabel A.; Dance, David R.; Skinner, Claire L.; Evans, Phil M.

    2005-08-15

    A Monte Carlo based computer model has been developed for electron beam computed tomography (EBCT) to calculate organ and effective doses in a humanoid hermaphrodite phantom. The program has been validated by comparison with experimental measurements of the CT dose index in standard head and body CT dose phantoms; agreement to better than 8% has been found. The robustness of the model has been established by varying the input parameters. The amount of energy deposited at the 12:00 position of the standard body CT dose phantom is most susceptible to rotation angle, whereas that in the central region is strongly influenced by the beam quality. The program has been used to investigate the changes in organ absorbed doses arising from partial and full rotation about supine and prone subjects. Superficial organs experience the largest changes in absorbed dose with a change in subject orientation and for partial rotation. Effective doses for typical clinical scan protocols have been calculated and compared with values obtained using existing dosimetry techniques based on full rotation. Calculations which make use of Monte Carlo conversion factors for the scanner that best matches the EBCT dosimetric characteristics consistently overestimate the effective dose in supine subjects by typically 20%, and underestimate the effective dose in prone subjects by typically 13%. These factors can therefore be used to correct values obtained in this way. Empirical dosimetric techniques based on the dose-length product yield errors as great as 77%. This is due to the sensitivity of the dose length product to individual scan lengths. The magnitude of these errors is reduced if empirical dosimetric techniques based on the average absorbed dose in the irradiated volume (CTDI{sub vol}) are used. Therefore conversion factors specific to EBCT have been calculated to convert the CTDI{sub vol} to an effective dose.

  1. Low radiation dose in computed tomography: the role of iodine.

    PubMed

    Aschoff, Andrik J; Catalano, Carlo; Kirchin, Miles A; Krix, Martin; Albrecht, Thomas

    2017-08-01

    Recent approaches to reducing radiation exposure during CT examinations typically utilize automated dose modulation strategies on the basis of lower tube voltage combined with iterative reconstruction and other dose-saving techniques. Less clearly appreciated is the potentially substantial role that iodinated contrast media (CM) can play in low-radiation-dose CT examinations. Herein we discuss the role of iodinated CM in low-radiation-dose examinations and describe approaches for the optimization of CM administration protocols to further reduce radiation dose and/or CM dose while maintaining image quality for accurate diagnosis. Similar to the higher iodine attenuation obtained at low-tube-voltage settings, high-iodine-signal protocols may permit radiation dose reduction by permitting a lowering of mAs while maintaining the signal-to-noise ratio. This is particularly feasible in first pass examinations where high iodine signal can be achieved by injecting iodine more rapidly. The combination of low kV and IR can also be used to reduce the iodine dose. Here, in optimum contrast injection protocols, the volume of CM administered rather than the iodine concentration should be reduced, since with high-iodine-concentration CM further reductions of iodine dose are achievable for modern first pass examinations. Moreover, higher concentrations of CM more readily allow reductions of both flow rate and volume, thereby improving the tolerability of contrast administration.

  2. Low radiation dose in computed tomography: the role of iodine

    PubMed Central

    Aschoff, Andrik J; Catalano, Carlo; Krix, Martin; Albrecht, Thomas

    2017-01-01

    Recent approaches to reducing radiation exposure during CT examinations typically utilize automated dose modulation strategies on the basis of lower tube voltage combined with iterative reconstruction and other dose-saving techniques. Less clearly appreciated is the potentially substantial role that iodinated contrast media (CM) can play in low-radiation-dose CT examinations. Herein we discuss the role of iodinated CM in low-radiation-dose examinations and describe approaches for the optimization of CM administration protocols to further reduce radiation dose and/or CM dose while maintaining image quality for accurate diagnosis. Similar to the higher iodine attenuation obtained at low-tube-voltage settings, high-iodine-signal protocols may permit radiation dose reduction by permitting a lowering of mAs while maintaining the signal-to-noise ratio. This is particularly feasible in first pass examinations where high iodine signal can be achieved by injecting iodine more rapidly. The combination of low kV and IR can also be used to reduce the iodine dose. Here, in optimum contrast injection protocols, the volume of CM administered rather than the iodine concentration should be reduced, since with high-iodine-concentration CM further reductions of iodine dose are achievable for modern first pass examinations. Moreover, higher concentrations of CM more readily allow reductions of both flow rate and volume, thereby improving the tolerability of contrast administration. PMID:28471242

  3. Radiation effects on livestock: physiological effects, dose response

    SciTech Connect

    Bell, M.C.

    1985-06-01

    Farm livestock show no measurable effects from being exposed to ionizing radiation unless the level is greatly in excess of the natural background radiation. Possible sources of ionizing radiation which might affect livestock or contribute to radioactivity in the food chain to humans are reactor accidents, fuel reprocessing plant accidents and thermonuclear explosions. Most data on ionizing radiation effects on livestock are from whole body gamma doses near the LD 50/60 level. However, grazing livestock would be subjected to added beta exposure from ingested and skin retained radioactive particles. Results of attempts to simulate exposure of the Hereford cattle at Alamogardo, NM show that cattle are more sensitive to ingested fallout radiation than other species. Poultry LD 50/60 for gamma exposure is about twice the level for mammals, and swine appear to have the most efficient repair system being able to withstand the most chronic gamma exposure. Productivity of most livestock surviving an LD 50/60 exposure is temporarily reduced and longterm effects are small. Livestock are good screeners against undesirables in our diet and with the exception of radiosotopes of iodine in milk, very little fission product radioactivity would be expected to be transferred through the food chain in livestock products for humans. Feeding of stored feed or moving livestock to uncontaminated pastures would be the best protective action to follow. 29 references.

  4. The Concentration Of Tritium In Urine And Internal Radiation Dose Estimation Of PTNBR Radiation Workers

    SciTech Connect

    Tjahaja, Poppy Intan; Sukmabuana, Putu; Aisyah, Neneng Nur

    2010-12-23

    The operation of Triga 2000 reactor in Nuclear Technology Center for Materials and Radiometry (PTNBR BATAN) normally produce tritium radionuclide which is the activation product of deuterium atom in reactor primary cooling water. According to previous monitoring, tritium was detected with the concentration of 8.236{+-}0.677 kBq/L and 1.704{+-}0.046 Bq/L in the primary cooling water and in reactor hall air, respectively. The tritium in reactor hall air chronically can be inhaled by the workers. In this research, tritium content in radiation workers' urine was determined to estimate the internal radiation doses received by the workers. About 50-100 mL of urine samples were collected from 48 PTNBR workers that is classified as 24 radiation workers and 24 administration staffs as a control. Urine samples of 25 mL were then prepared by active charcoal and KMnO{sub 4} addition and followed with complete distillation. The 2 mL of distillate was added with 13 mL scintillator, shaked vigorously and remained in cool and dark condition for about 24 hours. The tritium in the samples was then measured using liquid scintillation counter (LSC) for 1 hour. From the measurement results it was obtained that the tritium concentration in the urine of radiation workers were in the range of not detected and 5.191 Bq/mL, whereas in the administration staffs the concentration were between not detected and 4.607 Bq/mL. Internally radiation doses were calculated using the tritium concentration data, and it was found the averages about 0.602 {mu}Sv/year and 0.532 {mu}Sv/year for radiation workers and administration staffs, respectively. The doses received by the workers were lower than that of the permissible doses from tritium, i.e. 40 {mu}Sv/year.

  5. Health Benefits of Exposure to Low-dose Radiation.

    PubMed

    Rithidech, Kanokporn Noy

    2016-03-01

    Although there is no doubt that exposure to high doses of radiation (delivered at a high dose-rate) induces harmful effects, the health risks and benefits of exposure to low levels (delivered at a low dose-rate) of toxic agents is still a challenging public health issue. There has been a considerable amount of published data against the linear no-threshold (LNT) model for assessing risk of cancers induced by radiation. The LNT model for risk assessment creates "radiophobia," which is a serious public health issue. It is now time to move forward to a paradigm shift in health risk assessment of low-dose exposure by taking the differences between responses to low and high doses into consideration. Moreover, future research directed toward the identification of mechanisms associated with responses to low-dose radiation is critically needed to fully understand their beneficial effects.

  6. SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT.

    PubMed

    Halliburton, Sandra S; Abbara, Suhny; Chen, Marcus Y; Gentry, Ralph; Mahesh, Mahadevappa; Raff, Gilbert L; Shaw, Leslee J; Hausleiter, Jörg

    2011-01-01

    Over the last few years, computed tomography (CT) has developed into a standard clinical test for a variety of cardiovascular conditions. The emergence of cardiovascular CT during a period of dramatic increase in radiation exposure to the population from medical procedures and heightened concern about the subsequent potential cancer risk has led to intense scrutiny of the radiation burden of this new technique. This has hastened the development and implementation of dose reduction tools and prompted closer monitoring of patient dose. In an effort to aid the cardiovascular CT community in incorporating patient-centered radiation dose optimization and monitoring strategies into standard practice, the Society of Cardiovascular Computed Tomography has produced a guideline document to review available data and provide recommendations regarding interpretation of radiation dose indices and predictors of risk, appropriate use of scanner acquisition modes and settings, development of algorithms for dose optimization, and establishment of procedures for dose monitoring.

  7. SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT

    PubMed Central

    Halliburton, Sandra S.; Abbara, Suhny; Chen, Marcus Y.; Gentry, Ralph; Mahesh, Mahadevappa; Raff, Gilbert L.; Shaw, Leslee J.; Hausleiter, Jörg

    2012-01-01

    Over the last few years, computed tomography (CT) has developed into a standard clinical test for a variety of cardiovascular conditions. The emergence of cardiovascular CT during a period of dramatic increase in radiation exposure to the population from medical procedures and heightened concern about the subsequent potential cancer risk has led to intense scrutiny of the radiation burden of this new technique. This has hastened the development and implementation of dose reduction tools and prompted closer monitoring of patient dose. In an effort to aid the cardiovascular CT community in incorporating patient-centered radiation dose optimization and monitoring strategies into standard practice, the Society of Cardiovascular Computed Tomography has produced a guideline document to review available data and provide recommendations regarding interpretation of radiation dose indices and predictors of risk, appropriate use of scanner acquisition modes and settings, development of algorithms for dose optimization, and establishment of procedures for dose monitoring. PMID:21723512

  8. Ultraviolet Radiation Dose National Standard of México

    NASA Astrophysics Data System (ADS)

    Cardoso, R.; Rosas, E.

    2006-09-01

    We present the Ultraviolet (UV) Radiation Dose National Standard for México. The establishment of this measurement reference at Centro Nacional de Metrología (CENAM) eliminates the need of contacting foreign suppliers in the search for traceability towards the SI units when calibrating instruments at 365 nm. Further more, the UV Radiation Dose National Standard constitutes a highly accurate and reliable source for the UV radiation dose measurements performed in medical and cosmetic treatments as in the the food and pharmaceutics disinfection processes, among other.

  9. Total-dose radiation effects data for semiconductor devices, volume 2

    NASA Technical Reports Server (NTRS)

    Price, W. E.; Martin, K. E.; Nichols, D. K.; Gauthier, M. K.; Brown, S. F.

    1981-01-01

    Total ionizing dose radiation test data on integrated circuits are analyzed. Tests were performed with the electron accelerator (Dynamitron) that provides a steady state 2.5 MeV electron beam. Some radiation exposures were made with a Cobalt-60 gamma ray source. The results obtained with the Cobalt-60 source are considered an approximate measure of the radiation damage that would be incurred by an equivalent dose of electrons.

  10. Austrian results from Matroshka poncho and organ dose determination

    NASA Astrophysics Data System (ADS)

    Hajek, M.; Bergmann, R.; Fugger, M.; Vana, N.

    Cosmic rays in low-earth orbits LEO primarily consist of high-energy charged particles originating from galactic cosmic radiation GCR energetic solar particle events SPE and trapped radiation belts These radiations of high linear energy transfer LET generally inflict greater biological damage than that resulting from typical terrestrial radiation hazards Particle and energy spectra are attenuated in interaction processes within shielding structures and within the human body Reliable assessment of health risks to astronaut crews is pivotal in the design of future expeditions into interplanetary space and requires knowledge of absorbed radiation doses in critical radiosensitive organs and tissues The European Space Agency ESA Matroshka experiment---conducted under the aegis of the German Aerospace Center DLR ---is aimed at simulating an astronaut s body during extravehicular activities EVA Matroshka basically consists of a human phantom torso attached to a base structure and covered with a protective carbon-fibre container acting as a spacesuit model The phantom is divided into 33 tissue-equivalent polyurethane slices of specific density for tissue and organs Natural bones are embedded Channels and cut-outs enable accommodation of active and passive radiation monitors The torso is dressed by a skin-equivalent poncho which is also designed for dosimeter integration The phantom houses in total 7 active and more than 6000 passive radiation sensors Thereof the Atomic Institute of the Austrian Universities ATI provided more than

  11. The development of remote wireless radiation dose monitoring system

    SciTech Connect

    Lee, Jin-woo; Jeong, Kyu-hwan; Kim, Jong-il; Im, Chae-wan

    2015-07-01

    Internet of things (IoT) technology has recently shown a large flow of IT trends in human life. In particular, our lives are now becoming integrated with a lot of items around the 'smart-phone' with IoT, including Bluetooth, Near Field Communication (NFC), Beacons, WiFi, and Global Positioning System (GPS). Our project focuses on the interconnection of radiation dosimetry and IoT technology. The radiation workers at a nuclear facility should hold personal dosimeters such as a Thermo-Luminescence Dosimeter (TLD), an Optically Stimulated Luminescence Dosimeter (OSL), pocket ionization chamber dosimeters, an Electronic Personal Dosimeter (EPD), or an alarm dosimeter on their body. Some of them have functions that generate audible or visible alarms to radiation workers in a real working area. However, such devices used in radiation fields these days have no functions for communicating with other areas or the responsible personnel in real time. In particular, when conducting a particular task in a high dose area, or a number of repair works within a radiation field, radiation dose monitoring is important for the health of the workers and the work efficiency. Our project aims at the development of a remote wireless radiation dose monitoring system (RWRD) that can be used to monitor the radiation dose in a nuclear facility for radiation workers and a radiation protection program In this project, a radiation dosimeter is the detection device for personal radiation dose, a smart phone is the mobile wireless communication tool, and, Beacon is the wireless starter for the detection, communication, and position of the worker using BLE (Bluetooth Low Energy). In this report, we report the design of the RWRD and a demonstration case in a real radiation field. (authors)

  12. Wound Trauma Alters Ionizing Radiation Dose Assessment

    DTIC Science & Technology

    2012-06-11

    the Chernobyl reactor meltdown, 10% of 237 victims exposed to radiation received thermal burns [3]. In animals including mice [4,5], rats [6,7...Barabanova AV: Significance of beta-radiation skin burns in Chernobyl patients for the theory and practice of radiopathology. Vojnosanit Pregl 2006, 63

  13. Microelectronic Chips For Radiation-Dose Tests

    NASA Technical Reports Server (NTRS)

    Buehler, Martin G.; Lin, Yu-Sang; Ray, Kevin P.; Sokoloski, Martin M.

    1993-01-01

    Custom-made single-chip complementary metal-oxide semiconductor (CMOS) integrated circuit designed to reveal effects of ionizing radiation on itself and similar integrated circuits. Potential terrestrial use: safety-oriented monitoring of ionizing radiation at nuclear powerplants, nuclear-waste sites, and the like.

  14. Second Solid Cancers After Radiation Therapy: A Systematic Review of the Epidemiologic Studies of the Radiation Dose-Response Relationship

    SciTech Connect

    Berrington de Gonzalez, Amy; Gilbert, Ethel; Curtis, Rochelle; Inskip, Peter; Kleinerman, Ruth; Morton, Lindsay; Rajaraman, Preetha; Little, Mark P.

    2013-06-01

    Rapid innovations in radiation therapy techniques have resulted in an urgent need for risk projection models for second cancer risks from high-dose radiation exposure, because direct observation of the late effects of newer treatments will require patient follow-up for a decade or more. However, the patterns of cancer risk after fractionated high-dose radiation are much less well understood than those after lower-dose exposures (0.1-5 Gy). In particular, there is uncertainty about the shape of the dose-response curve at high doses and about the magnitude of the second cancer risk per unit dose. We reviewed the available evidence from epidemiologic studies of second solid cancers in organs that received high-dose exposure (>5 Gy) from radiation therapy where dose-response curves were estimated from individual organ-specific doses. We included 28 eligible studies with 3434 second cancer patients across 11 second solid cancers. Overall, there was little evidence that the dose-response curve was nonlinear in the direction of a downturn in risk, even at organ doses of ≥60 Gy. Thyroid cancer was the only exception, with evidence of a downturn after 20 Gy. Generally the excess relative risk per Gray, taking account of age and sex, was 5 to 10 times lower than the risk from acute exposures of <2 Gy among the Japanese atomic bomb survivors. However, the magnitude of the reduction in risk varied according to the second cancer. The results of our review provide insights into radiation carcinogenesis from fractionated high-dose exposures and are generally consistent with current theoretical models. The results can be used to refine the development of second solid cancer risk projection models for novel radiation therapy techniques.

  15. The effect of radiation dose on the onset and progression of radiation-induced brain necrosis in the rat model.

    PubMed

    Hartl, Brad A; Ma, Htet S W; Hansen, Katherine S; Perks, Julian; Kent, Michael S; Fragoso, Ruben C; Marcu, Laura

    2017-07-01

    To provide a comprehensive understanding of how the selection of radiation dose affects the temporal and spatial progression of radiation-induced necrosis in the rat model. Necrosis was induced with a single fraction of radiation exposure, at doses ranging between 20 and 60 Gy, to the right hemisphere of 8-week-old Fischer rats from a linear accelerator. The development and progression of necrosis in the rats was monitored and quantified every other week with T1- and T2-weighted gadolinium contrast-enhanced MRI studies. The time to onset of necrosis was found to be dose-dependent, but after the initial onset, the necrosis progression rate and total volume generated was constant across different doses ranging between 30 and 60 Gy. Radiation doses less than 30 Gy did not develop necrosis within 33 weeks after treatment, indicating a dose threshold existing between 20 and 30 Gy. The highest dose used in this study led to the shortest time to onset of radiation-induced necrosis, while producing comparable disease progression dynamics after the onset. Therefore, for the radiation-induced necrosis rat model using a linear accelerator, the most optimum results were generated from a dose of 60 Gy.

  16. CT Radiation Dose Optimization and Estimation: an Update for Radiologists

    PubMed Central

    2012-01-01

    In keeping with the increasing utilization of CT examinations, the greater concern about radiation hazards from examinations has been addressed. In this regard, CT radiation dose optimization has been given a great deal of attention by radiologists, referring physicians, technologists, and physicists. Dose-saving strategies are continuously evolving in terms of imaging techniques as well as dose management. Consequently, regular updates of this issue are necessary especially for radiologists who play a pivotal role in this activity. This review article will provide an update on how we can optimize CT dose in order to maximize the benefit-to-risk ratio of this clinically useful diagnostic imaging method. PMID:22247630

  17. CT radiation dose optimization and estimation: an update for radiologists.

    PubMed

    Goo, Hyun Woo

    2012-01-01

    In keeping with the increasing utilization of CT examinations, the greater concern about radiation hazards from examinations has been addressed. In this regard, CT radiation dose optimization has been given a great deal of attention by radiologists, referring physicians, technologists, and physicists. Dose-saving strategies are continuously evolving in terms of imaging techniques as well as dose management. Consequently, regular updates of this issue are necessary especially for radiologists who play a pivotal role in this activity. This review article will provide an update on how we can optimize CT dose in order to maximize the benefit-to-risk ratio of this clinically useful diagnostic imaging method.

  18. Radiation dose reduction in computed tomography: techniques and future perspective

    PubMed Central

    Yu, Lifeng; Liu, Xin; Leng, Shuai; Kofler, James M; Ramirez-Giraldo, Juan C; Qu, Mingliang; Christner, Jodie; Fletcher, Joel G; McCollough, Cynthia H

    2011-01-01

    Despite universal consensus that computed tomography (CT) overwhelmingly benefits patients when used for appropriate indications, concerns have been raised regarding the potential risk of cancer induction from CT due to the exponentially increased use of CT in medicine. Keeping radiation dose as low as reasonably achievable, consistent with the diagnostic task, remains the most important strategy for decreasing this potential risk. This article summarizes the general technical strategies that are commonly used for radiation dose management in CT. Dose-management strategies for pediatric CT, cardiac CT, dual-energy CT, CT perfusion and interventional CT are specifically discussed, and future perspectives on CT dose reduction are presented. PMID:22308169

  19. Radiation dose reduction in computed tomography: techniques and future perspective.

    PubMed

    Yu, Lifeng; Liu, Xin; Leng, Shuai; Kofler, James M; Ramirez-Giraldo, Juan C; Qu, Mingliang; Christner, Jodie; Fletcher, Joel G; McCollough, Cynthia H

    2009-10-01

    Despite universal consensus that computed tomography (CT) overwhelmingly benefits patients when used for appropriate indications, concerns have been raised regarding the potential risk of cancer induction from CT due to the exponentially increased use of CT in medicine. Keeping radiation dose as low as reasonably achievable, consistent with the diagnostic task, remains the most important strategy for decreasing this potential risk. This article summarizes the general technical strategies that are commonly used for radiation dose management in CT. Dose-management strategies for pediatric CT, cardiac CT, dual-energy CT, CT perfusion and interventional CT are specifically discussed, and future perspectives on CT dose reduction are presented.

  20. Effects of Chronic Low-Dose Radiation on Human Neural Progenitor Cells

    NASA Astrophysics Data System (ADS)

    Katsura, Mari; Cyou-Nakamine, Hiromasa; Zen, Qin; Zen, Yang; Nansai, Hiroko; Amagasa, Shota; Kanki, Yasuharu; Inoue, Tsuyoshi; Kaneki, Kiyomi; Taguchi, Akashi; Kobayashi, Mika; Kaji, Toshiyuki; Kodama, Tatsuhiko; Miyagawa, Kiyoshi; Wada, Youichiro; Akimitsu, Nobuyoshi; Sone, Hideko

    2016-01-01

    The effects of chronic low-dose radiation on human health have not been well established. Recent studies have revealed that neural progenitor cells are present not only in the fetal brain but also in the adult brain. Since immature cells are generally more radiosensitive, here we investigated the effects of chronic low-dose radiation on cultured human neural progenitor cells (hNPCs) derived from embryonic stem cells. Radiation at low doses of 31, 124 and 496 mGy per 72 h was administered to hNPCs. The effects were estimated by gene expression profiling with microarray analysis as well as morphological analysis. Gene expression was dose-dependently changed by radiation. By thirty-one mGy of radiation, inflammatory pathways involving interferon signaling and cell junctions were altered. DNA repair and cell adhesion molecules were affected by 124 mGy of radiation while DNA synthesis, apoptosis, metabolism, and neural differentiation were all affected by 496 mGy of radiation. These in vitro results suggest that 496 mGy radiation affects the development of neuronal progenitor cells while altered gene expression was observed at a radiation dose lower than 100 mGy. This study would contribute to the elucidation of the clinical and subclinical phenotypes of impaired neuronal development induced by chronic low-dose radiation.

  1. Effects of Chronic Low-Dose Radiation on Human Neural Progenitor Cells

    PubMed Central

    Katsura, Mari; Cyou-Nakamine, Hiromasa; Zen, Qin; Zen, Yang; Nansai, Hiroko; Amagasa, Shota; Kanki, Yasuharu; Inoue, Tsuyoshi; Kaneki, Kiyomi; Taguchi, Akashi; Kobayashi, Mika; Kaji, Toshiyuki; Kodama, Tatsuhiko; Miyagawa, Kiyoshi; Wada, Youichiro; Akimitsu, Nobuyoshi; Sone, Hideko

    2016-01-01

    The effects of chronic low-dose radiation on human health have not been well established. Recent studies have revealed that neural progenitor cells are present not only in the fetal brain but also in the adult brain. Since immature cells are generally more radiosensitive, here we investigated the effects of chronic low-dose radiation on cultured human neural progenitor cells (hNPCs) derived from embryonic stem cells. Radiation at low doses of 31, 124 and 496 mGy per 72 h was administered to hNPCs. The effects were estimated by gene expression profiling with microarray analysis as well as morphological analysis. Gene expression was dose-dependently changed by radiation. By thirty-one mGy of radiation, inflammatory pathways involving interferon signaling and cell junctions were altered. DNA repair and cell adhesion molecules were affected by 124 mGy of radiation while DNA synthesis, apoptosis, metabolism, and neural differentiation were all affected by 496 mGy of radiation. These in vitro results suggest that 496 mGy radiation affects the development of neuronal progenitor cells while altered gene expression was observed at a radiation dose lower than 100 mGy. This study would contribute to the elucidation of the clinical and subclinical phenotypes of impaired neuronal development induced by chronic low-dose radiation. PMID:26795421

  2. Effects of Chronic Low-Dose Radiation on Human Neural Progenitor Cells.

    PubMed

    Katsura, Mari; Cyou-Nakamine, Hiromasa; Zen, Qin; Zen, Yang; Nansai, Hiroko; Amagasa, Shota; Kanki, Yasuharu; Inoue, Tsuyoshi; Kaneki, Kiyomi; Taguchi, Akashi; Kobayashi, Mika; Kaji, Toshiyuki; Kodama, Tatsuhiko; Miyagawa, Kiyoshi; Wada, Youichiro; Akimitsu, Nobuyoshi; Sone, Hideko

    2016-01-22

    The effects of chronic low-dose radiation on human health have not been well established. Recent studies have revealed that neural progenitor cells are present not only in the fetal brain but also in the adult brain. Since immature cells are generally more radiosensitive, here we investigated the effects of chronic low-dose radiation on cultured human neural progenitor cells (hNPCs) derived from embryonic stem cells. Radiation at low doses of 31, 124 and 496 mGy per 72 h was administered to hNPCs. The effects were estimated by gene expression profiling with microarray analysis as well as morphological analysis. Gene expression was dose-dependently changed by radiation. By thirty-one mGy of radiation, inflammatory pathways involving interferon signaling and cell junctions were altered. DNA repair and cell adhesion molecules were affected by 124 mGy of radiation while DNA synthesis, apoptosis, metabolism, and neural differentiation were all affected by 496 mGy of radiation. These in vitro results suggest that 496 mGy radiation affects the development of neuronal progenitor cells while altered gene expression was observed at a radiation dose lower than 100 mGy. This study would contribute to the elucidation of the clinical and subclinical phenotypes of impaired neuronal development induced by chronic low-dose radiation.

  3. Ionizing Radiation Doses Detected at the Eye Level of the Primary Surgeon During Orthopaedic Procedures.

    PubMed

    Cheriachan, Deepak; Hughes, Adrian M; du Moulin, William S M; Williams, Christopher; Molnar, Robert

    2016-07-01

    To evaluate the ionizing radiation dose received by the eyes of orthopaedic surgeons during various orthopaedic procedures. Secondary objective was to compare the ionizing radiation dose received between differing experience level. Prospective comparative study between January 2013 and May 2014. Westmead Hospital, a Level 1 Trauma Centre for Greater Western Sydney. A total of 26 surgeons volunteered to participate within the study. Experience level, procedure performed, fluoroscopy time, dose area product, total air kerma, and eye dose received was recorded. Participants were evaluated on procedure and experience level. Radiation dose received at eye level by the primary surgeon during an orthopaedic procedure. Data from a total of 131 cases was recorded and included for analysis. The mean radiation dose detected at the eye level of the primary surgeon was 0.02 mSv (SD = 0.05 mSv) per procedure. Radiation at eye level was only detected in 31 of the 131 cases. The highest registered dose for a single procedure was 0.31 mSv. Femoral nails and pelvic fixation procedures had a significantly higher mean dose received than other procedure groups (0.04 mSv (SD = 0.07 mSv) and 0.04 mSv (SD = 0.06 mSv), respectively). Comparing the eye doses received by orthopaedic consultants and trainees, there was no significant difference between the 2 groups. The risk of harmful levels of radiation exposure at eye level to orthopaedic surgeons is low. This risk is greatest during insertion of femoral intramedullary nails and pelvic fixation, and it is recommended that in these situations, surgeons take all reasonable precautions to minimize radiation dose. The orthopaedic trainees in this study were not subjected to higher doses of radiation than their consultant trainers. On the basis of these results, most of the orthopaedic surgeons remain well below the yearly radiation dose of 20 mSv as recommended by the International Commission on Radiological Protection.

  4. Radiation Dose to Newborns in Neonatal Intensive Care Units

    PubMed Central

    Bahreyni Toossi, Mohammad Taghi; Malekzadeh, Malakeh

    2012-01-01

    Background With the increase of X-ray use for medical diagnostic purposes, knowing the given doses is necessary in patients for comparison with reference levels. The concept of reference doses or diagnostic reference levels (DRLs) has been developed as a practical aid in the optimization of patient protection in diagnostic radiology. Objectives To assess the radiation doses to neonates from diagnostic radiography (chest and abdomen). This study has been carried out in the neonatal intensive care unit of a province in Iran. Patients and Methods Entrance surface dose (ESD) was measured directly with thermoluminescent dosimeters (TLDs). The population included 195 neonates admitted for a diagnostic radiography, in eight NICUs of different hospital types. Results The mean ESD for chest and abdomen examinations were 76.3 µGy and 61.5 µGy, respectively. DRLs for neonate in NICUs of the province were 88 µGy for chest and 98 µGy for abdomen examinations that were slightly higher than other studies. Risk of death due to radiation cancer incidence of abdomens examination was equal to 1.88 × 10 -6 for male and 4.43 × 10 -6 for female. For chest X-ray, it was equal to 2.54 × 10 -6 for male and 1.17 × 10 -5 for female patients. Conclusion DRLs for neonates in our province were slightly higher than values reported by other studies such as European national diagnostic reference levels and the NRPB reference dose. The main reason was related to using a high mAs and a low kVp applied in most departments and also a low focus film distance (FFD). Probably lack of collimation also affected some exams in the NICUs. PMID:23329980

  5. Contribution of maternal radionuclide burdens to prenatal radiation doses

    SciTech Connect

    Sikov, M.R.; Hui, T.E.; Meznarich, H.K.; Thrall, K.D. . Div. of Regulatory Applications); Traub, R.J. )

    1992-03-01

    This report discusses approaches to calculating and expressing radiation doses to the embryo/fetus from internal radionuclides. Information was obtained for selected, occupationally significant radionuclides in chemical forms that provided a spectrum of metabolic and dosimetric characteristics. Fractional placental transfer and/or ratios of concentration in the embryo/fetus to that in the woman were estimated for these materials, and were combined with data from biokinetic transfer models to predict radioactivity levels in the embryo/fetus as a function of stage of pregnancy and time after entry into the transfer compartment or blood of the pregnant woman. Medical Internal Radiation Dosimetry (MIRD) methodologies were extended to formalize and describe details for calculating radiation absorbed doses to the embryo/fetus. Calculations were performed for representative situations; introduction of 1 {mu}Ci into a woman's blood at successive months of pregnancy was assumed to accommodate the stage dependence of geometric relationships and biological behaviors. Summary tables of results, correlations, and dosimetric relations, and of tentative generalized categorizations, are provided in the report.

  6. Prefecture-wide multi-centre radiation dose survey as a useful tool for CT dose optimisation: report of Gunma radiation dose study.

    PubMed

    Fukushima, Yasuhiro; Taketomi-Takahashi, Ayako; Nakajima, Takahito; Tsushima, Yoshito

    2015-12-01

    The aim of this study was to verify the usefulness for the dose optimisation of setting a diagnostic reference level (DRL) based on the results of a prefecture-wide multi-centre radiation dose survey and providing data feedback. All hospitals/clinics in the authors' prefecture with computed tomography (CT) scanners were requested to report data. The first survey was done in July 2011, and the results of dose-length products (DLPs) for each CT scanner were fed back to all hospitals/clinics, with DRL set from all the data. One year later, a second survey was done in the same manner. The medians of DLP in the upper abdomen, whole body and coronary CT in 2012 were significantly smaller than those of the 2011 survey. The interquartile ranges of DLP in the head, chest, pelvis and coronary CT were also smaller in 2012. Radiation dose survey with data feedback may be helpful for CT dose optimisation. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Modeling the radiation doses from terrestrial gamma-ray flashes

    NASA Astrophysics Data System (ADS)

    Dwyer, Joseph; Liu, Ningyu; Rassoul, Hamid

    2013-04-01

    Terrestrial gamma-ray flashes (TGFs) are intense bursts of gamma-rays that originate from thunderclouds, from altitudes that commercial aircraft fly. Based upon the fluence of gamma-rays measured by the RHESSI spacecraft, Dwyer et al. [2010] inferred radiation doses to individuals inside aircraft in the 0.001 - 0.1 Sv range, depending upon the assumed size of the TGF source region. The largest doses occur when an aircraft is directly struck by the energetic electron beam that produces the TGF. The relativistic feedback discharge model is a self-consistent model that includes the generation of runaway electrons via the positron and x-ray feedback mechanisms and the electric field changes due to the resulting ionization and low-energy electron and ion currents. This model has successfully explained many properties of TGFs, including the gamma-ray intensities, durations, multi-pulsed structures as well as discharge currents and radio emissions. In this presentation we discuss new radiation dose calculations based upon the relativistic feedback discharge model and compare these calculations to previous work.

  8. Effective Dose from Stray Radiation for a Patient Receiving Proton Therapy for Liver Cancer

    NASA Astrophysics Data System (ADS)

    Taddei, Phillip J.; Krishnan, Sunil; Mirkovic, Dragan; Yepes, Pablo; Newhauser, Wayne D.

    2009-03-01

    Because of its advantageous depth-dose relationship, proton radiotherapy is an emerging treatment modality for patients with liver cancer. Although the proton dose distribution conforms to the target, healthy tissues throughout the body receive low doses of stray radiation, particularly neutrons that originate in the treatment unit or in the patient. The aim of this study was to calculate the effective dose from stray radiation and estimate the corresponding risk of second cancer fatality for a patient receiving proton beam therapy for liver cancer. Effective dose from stray radiation was calculated using detailed Monte Carlo simulations of a double-scattering proton therapy treatment unit and a voxelized human phantom. The treatment plan and phantom were based on CT images of an actual adult patient diagnosed with primary hepatocellular carcinoma. For a prescribed dose of 60 Gy to the clinical target volume, the effective dose from stray radiation was 370 mSv; 61% of this dose was from neutrons originating outside of the patient while the remaining 39% was from neutrons originating within the patient. The excess lifetime risk of fatal second cancer corresponding to the total effective dose from stray radiation was 1.2%. The results of this study establish a baseline estimate of the stray radiation dose and corresponding risk for an adult patient undergoing proton radiotherapy for liver cancer and provide new evidence to corroborate the suitability of proton beam therapy for the treatment of liver tumors.

  9. Painting Dose: The ART of Radiation.

    PubMed

    Roberts, Hannah J; Zietman, Anthony L; Efstathiou, Jason A

    2016-11-15

    The discovery of X rays in 1895 captivated society like no other scientific advance. Radiation instantly became the subject not only of numerous scientific papers but also of circus bazaars, poetry, fiction, costume design, comics, and marketing for household items. Its spread was "viral." What is not well known, however, is its incorporation into visual art, despite the long tradition of medicine and surgery as a subject in art. Using several contemporary search methods, we identified 5 examples of paintings or sculpture that thematically feature radiation therapy. All were by artists with exhibited careers in art: Georges Chicotot, Marcel Duchamp, David Alfaro Siqueiros, Robert Pope, and Cookie Kerxton. Each artist portrays radiation differently, ranging from traditional healer, to mysterious danger, to futuristic propaganda, to the emotional challenges of undergoing cancer therapy. This range captures the complex role of radiation as both a therapy and a hazard. Whereas some of these artists are now world famous, none of these artworks are as well known as their surgical counterparts. The penetration of radiation into popular culture was rapid and pervasive; yet, its role as a thematic subject in art never fully caught on, perhaps because of a lack of understanding of the technology, radiation's intangibility, or even a suppressive effect of society's ambivalent relationship with it. These 5 artists have established a rich foundation upon which pop culture and art can further develop with time to reflect the extraordinary progress of modern radiation therapy.

  10. Estimation of Effective Doses for Radiation Cancer Risks on ISS, Lunar, and Mars Missions with Space Radiation Measurement

    NASA Technical Reports Server (NTRS)

    Kim, M.Y.; Cucinotta, F.A.

    2005-01-01

    Radiation protection practices define the effective dose as a weighted sum of equivalent dose over major sites for radiation cancer risks. Since a crew personnel dosimeter does not make direct measurement of effective dose, it has been estimated with skin-dose measurements and radiation transport codes for ISS and STS missions. The Phantom Torso Experiment (PTE) of NASA s Operational Radiation Protection Program has provided the actual flight measurements of active and passive dosimeters which were placed throughout the phantom on STS-91 mission for 10 days and on ISS Increment 2 mission. For the PTE, the variation in organ doses, which is resulted by the absorption and the changes in radiation quality with tissue shielding, was considered by measuring doses at many tissue sites and at several critical body organs including brain, colon, heart, stomach, thyroid, and skins. These measurements have been compared with the organ dose calculations obtained from the transport models. Active TEPC measurements of lineal energy spectra at the surface of the PTE also provided the direct comparison of galactic cosmic ray (GCR) or trapped proton dose and dose equivalent. It is shown that orienting the phantom body as actual in ISS is needed for the direct comparison of the transport models to the ISS data. One of the most important observations for organ dose equivalent of effective dose estimates on ISS is the fractional contribution from trapped protons and GCR. We show that for most organs over 80% is from GCR. The improved estimation of effective doses for radiation cancer risks will be made with the resultant tissue weighting factors and the modified codes.

  11. Estimation of Effective Doses for Radiation Cancer Risks on ISS, Lunar, and Mars Missions with Space Radiation Measurement

    NASA Technical Reports Server (NTRS)

    Kim, M.Y.; Cucinotta, F.A.

    2005-01-01

    Radiation protection practices define the effective dose as a weighted sum of equivalent dose over major sites for radiation cancer risks. Since a crew personnel dosimeter does not make direct measurement of effective dose, it has been estimated with skin-dose measurements and radiation transport codes for ISS and STS missions. The Phantom Torso Experiment (PTE) of NASA s Operational Radiation Protection Program has provided the actual flight measurements of active and passive dosimeters which were placed throughout the phantom on STS-91 mission for 10 days and on ISS Increment 2 mission. For the PTE, the variation in organ doses, which is resulted by the absorption and the changes in radiation quality with tissue shielding, was considered by measuring doses at many tissue sites and at several critical body organs including brain, colon, heart, stomach, thyroid, and skins. These measurements have been compared with the organ dose calculations obtained from the transport models. Active TEPC measurements of lineal energy spectra at the surface of the PTE also provided the direct comparison of galactic cosmic ray (GCR) or trapped proton dose and dose equivalent. It is shown that orienting the phantom body as actual in ISS is needed for the direct comparison of the transport models to the ISS data. One of the most important observations for organ dose equivalent of effective dose estimates on ISS is the fractional contribution from trapped protons and GCR. We show that for most organs over 80% is from GCR. The improved estimation of effective doses for radiation cancer risks will be made with the resultant tissue weighting factors and the modified codes.

  12. Daily Sodium Butyrate Enema for the Prevention of Radiation Proctitis in Prostate Cancer Patients Undergoing Radical Radiation Therapy: Results of a Multicenter Randomized Placebo-Controlled Dose-Finding Phase 2 Study

    SciTech Connect

    Maggio, Angelo; Magli, Alessandro; Rancati, Tiziana; Fiorino, Claudio; Valvo, Francesca; Fellin, Giovanni; Ricardi, Umberto; Munoz, Fernando; Cosentino, Dorian; Cazzaniga, Luigi Franco; Valdagni, Riccardo; Vavassori, Vittorio

    2014-07-01

    Purpose: To evaluate the efficacy of sodium butyrate enemas (NABUREN) in prostate cancer radiation therapy (RT) in reducing the incidence, severity, and duration of acute RT-induced proctitis. Methods and Materials: 166 patients, randomly allocated to 1 of 4 groups (rectal sodium butyrate 1 g, 2 g, or 4 g daily or placebo), were treated with NABUREN during and 2 weeks after RT. The grade of proctitis was registered in a daily diary. The correlation between NABUREN and proctitis was investigated through χ{sup 2} statistics. The toxicity endpoints considered were as follows: total number of days with grade ≥1 proctitis (≥G1); total number of days with grade ≥2 proctitis (≥G2); ≥G1 and ≥G2 proctitis lasting at least 3 and 5 consecutive days starting from week 4 (≥G1+3d, ≥G2+3d); damaging effects of RT on rectal mucosa as measured by endoscopy. The relationship between endpoints and pretreatment morbidities, hormonal therapy, presence of diabetes or hypertension, abdominal surgery, or hemorrhoids was investigated by univariate analysis. Results: The patients were randomly allocated to the 4 arms. No difference in the distribution of comorbidities among the arms was observed (P>.09). The mean ≥G1 and ≥G2 proctitis were 7.8 and 4.9 for placebo and 8.9 and 4.7 for the NABUREN group, respectively. No favorable trend in reduction of incidence, severity, and duration of ≥G1 and ≥G2 proctitis was observed with NABUREN use. In univariate analysis, ≥G1+3d toxicity was found to be related to hemorrhoids (P=.008), and a slight correlation was found between ≥G2 proctitis and hormonal therapy (P=.06). The RT effects on rectal mucosa as based on endoscopic assessment were mainly related to diabetes (P<.01). Endoscopy data at 6 week showed no significant difference between the placebo and butyrate arms. The other investigated endpoints were not correlated with any of the clinical risk factors analyzed. Conclusion: There was no evidence of efficacy

  13. Perspectives on radiation dose estimates for A-bomb survivors

    SciTech Connect

    Loewe, W.E.

    1986-12-01

    Four decades after the actual events, quantitative characterization of the radiation fields at Hiroshima and Nagasaki continues to be sought, with high accuracy a goal justified by the unique contribution to radiation protection standards that is represented by the medical records of exposed survivors. The most recent effort is distinguished by its reliance on computer modeling and concomitant detail, and by its decentralized direction, both internationally and internally to the US and Japan, with resultant ongoing peer review and wide scope of inquiry. A new system for individual dose estimation has been agreed upon, and its scientific basis has been elaborated in the literature as well as in a comprehensive treatise to be published in the Spring of 1987. In perspective, this new system appears to be an unusually successful achievement that offers the expectation of reliable estimates with the desired accuracy. Some aspects leading to this expectation, along with a caveat, are discussed here. 4 refs., 8 figs., 3 tabs.

  14. Radiation quality and the shape of dose-effect curves at low doses of ionizing radiation for eukaryotic cells.

    PubMed

    Petin, V G; Kapultcevich, Yu G

    2014-06-01

    To explain different yeast and mammalian cell response to low and high linear energy transfer (LET) radiation in low dose region, the dependence of fine target structure on the stage of cell growth was supposed. Theoretical consideration based on this suggestion was carried out. Results of calculations are qualitatively in agreement with experimental data under assuming that hit-event for both mammalian and yeast cells is a group of ionizations produced by the same ionizing particle. In the dependence of cell cycle phase, sensitive sites (presumable the vulnerable sections of chromosomes) can be located either in periphery of cell nucleus forming a thin layer inside the nucleus or distributed evenly over the whole nucleus. Such rearrangement of the target results in the alteration of the dependence of both survival curve shape and the relative biological effectiveness values on radiation quality. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. COSMIC: A Regimen of Intensity Modulated Radiation Therapy Plus Dose-Escalated, Raster-Scanned Carbon Ion Boost for Malignant Salivary Gland Tumors: Results of the Prospective Phase 2 Trial

    SciTech Connect

    Jensen, Alexandra D.; Nikoghosyan, Anna V.; Lossner, Karen; Haberer, Thomas; Jäkel, Oliver; Münter, Marc W.; Debus, Jürgen

    2015-09-01

    Purpose: To investigate the effect of intensity modulated radiation therapy (IMRT) and dose-escalated carbon ion (C12) therapy in adenoid cystic carcinoma (ACC) and other malignant salivary gland tumors (MSGTs) of the head and neck. Patients and Methods: COSMIC (combined treatment of malignant salivary gland tumors with intensity modulated radiation therapy and carbon ions) is a prospective phase 2 trial of 24 Gy(RBE) C12 followed by 50 Gy IMRT in patients with pathologically confirmed MSGT. The primary endpoint is mucositis Common Terminology Criteria grade 3; the secondary endpoints are locoregional control (LC), progression-free survival (PFS), overall survival (OS), and toxicity. Toxicity was scored according to the Common Terminology Criteria for Adverse Events version 3; treatment response was scored according to Response Evaluation Criteria in Solid Tumors 1.1. Results: Between July 2010 and August 2011, 54 patients were accrued, and 53 were available for evaluation. The median follow-up time was 42 months; patients with microscopically incomplete resections (R1, n=20), gross residual disease (R2, n=17), and inoperable disease (n=16) were included. Eighty-nine percent of patients had ACC, and 57% had T4 tumors. The most common primary sites were paranasal sinus (34%), submandibular gland, and palate. At the completion of radiation therapy, 26% of patients experienced grade 3 mucositis, and 20 patients reported adverse events of the ear (38%). The most common observed late effects were grade 1 xerostomia (49%), hearing impairment (25%, 2% ipsilateral hearing loss), and adverse events of the eye (20%), but no visual impairment or loss of vision. Grade 1 central nervous system necrosis occurred in 6%, and 1 grade 4 ICA hemorrhage without neurologic sequelae. The best response was 54% (complete response/partial remission). At 3 years, the LC, PFS, and OS were 81.9%, 57.9%, and 78.4%, respectively. No difference was found regarding resection status. The

  16. Digital radiography in paediatrics: radiation dose considerations and magnitude of possible dose reduction.

    PubMed

    Hufton, A P; Doyle, S M; Carty, H M

    1998-02-01

    The purpose of this study was to evaluate the radiation doses received by paediatric patients examined using a digital radiography unit, and to compare these doses with those received from conventional screen-film systems. In this way, guidelines could be drawn up concerning the magnitude of possible dose reductions achievable using digital radiography. The study was undertaken on approximately 900 patients undergoing abdomen, chest, pelvis and skull examinations. Patients were categorized into the following age groups: 0-1 month, 1-12 months, 1-5 years, 5-10 years and 10-15 years. Approximately half were X-rayed using a Fuji computed radiography system and half using a conventional screen-film system. Entrance surface dose was calculated from the recorded exposure parameters and measured X-ray tube outputs. Dose-area product was recorded directly. Image quality was assessed clinically using criteria recommended by a working group of the Commission of the European Communities. Apart from chest examinations, it was found possible to reduce doses by about 40% on average, by using a computed radiography system instead of a 600 speed screen-film combination. There was no significant difference in the dose for chest examinations. Satisfactory image quality can therefore be achieved by using computed radiography as a 1000 speed system for abdomen, pelvis and skull examinations, and as a 600 speed system for chests. Since very few departments appear to use screen-film systems of speeds greater than 400, then, for most departments, the use of computed radiography would result in dose reductions of at least 60%, or 33% for chests.

  17. Source term calculations for assessing radiation dose to equipment

    SciTech Connect

    Denning, R.S.; Freeman-Kelly, R.; Cybulskis, P.; Curtis, L.A.

    1989-07-01

    This study examines results of analyses performed with the Source Term Code Package to develop updated source terms using NUREG-0956 methods. The updated source terms are to be used to assess the adequacy of current regulatory source terms used as the basis for equipment qualification. Time-dependent locational distributions of radionuclides within a containment following a severe accident have been developed. The Surry reactor has been selected in this study as representative of PWR containment designs. Similarly, the Peach Bottom reactor has been used to examine radionuclide distributions in boiling water reactors. The time-dependent inventory of each key radionuclide is provided in terms of its activity in curies. The data are to be used by Sandia National Laboratories to perform shielding analyses to estimate radiation dose to equipment in each containment design. See NUREG/CR-5175, Beta and Gamma Dose Calculations for PWR and BWR Containments.'' 6 refs., 11 tabs.

  18. Strategies for reduction of radiation dose in cardiac multislice CT.

    PubMed

    Paul, Jean-François; Abada, Hicham T

    2007-08-01

    Because cardiac computed tomography (CT) (mainly coronary CT angiography) is a very promising technique, used more and more for coronary artery evaluation, the benefits and risks of this new low-invasive technique must be balanced. Radiation dose is a major concern for coronary CT angiography, especially in case of repeated examinations or in particular subgroups of patients (for example young female patients). Radiation dose to patient tends to increase from 16- to 64-slice CT. Radiation exposure in ECG-gated acquisitions may reach up to 40 mSv; considerable differences are attributable to the performance of CT machines, to technical dose-sparing tools, but also to radiological habits. Setting radiation dose at the lowest level possible should be a constant goal for the radiologist. Current technological tools are detailed in regard to their efficiency. Optimisation is necessary, by a judicious use of technological tools and also by individual adaptation of kV or mAs. This paper reviews the different current strategies for radiation dose reduction, keeping image quality constant. Data from the literature are discussed, and future technological developments are considered in regards to radiation dose reduction. The particular case of paediatric patients with congenital heart disease is also addressed.

  19. Methodology for estimating radiation dose rates to freshwater biota exposed to radionuclides in the environment

    SciTech Connect

    Blaylock, B.G.; Frank, M.L.; O`Neal, B.R.

    1993-08-01

    The purpose of this report is to present a methodology for evaluating the potential for aquatic biota to incur effects from exposure to chronic low-level radiation in the environment. Aquatic organisms inhabiting an environment contaminated with radioactivity receive external radiation from radionuclides in water, sediment, and from other biota such as vegetation. Aquatic organisms receive internal radiation from radionuclides ingested via food and water and, in some cases, from radionuclides absorbed through the skin and respiratory organs. Dose rate equations, which have been developed previously, are presented for estimating the radiation dose rate to representative aquatic organisms from alpha, beta, and gamma irradiation from external and internal sources. Tables containing parameter values for calculating radiation doses from selected alpha, beta, and gamma emitters are presented in the appendix to facilitate dose rate calculations. The risk of detrimental effects to aquatic biota from radiation exposure is evaluated by comparing the calculated radiation dose rate to biota to the U.S. Department of Energy`s (DOE`s) recommended dose rate limit of 0.4 mGy h{sup {minus}1} (1 rad d{sup {minus}1}). A dose rate no greater than 0.4 mGy h{sup {minus}1} to the most sensitive organisms should ensure the protection of populations of aquatic organisms. DOE`s recommended dose rate is based on a number of published reviews on the effects of radiation on aquatic organisms that are summarized in the National Council on Radiation Protection and Measurements Report No. 109 (NCRP 1991). DOE recommends that if the results of radiological models or dosimetric measurements indicate that a radiation dose rate of 0. 1 mGy h{sup {minus}1} will be exceeded, then a more detailed evaluation of the potential ecological consequences of radiation exposure to endemic populations should be conducted.

  20. Space Radiation Quality Factors and the Delta Ray Dose and Dose-Rate Reduction Effectiveness Factor.

    PubMed

    Cucinotta, Francis A; Cacao, Eliedonna; Alp, Murat

    2016-03-01

    In this paper, the authors recommend that the dose and dose-rate effectiveness factor used for space radiation risk assessments should be based on a comparison of the biological effects of energetic electrons produced along a cosmic ray particles path in low fluence exposures to high dose-rate gamma-ray exposures of doses of about 1 Gy. Methods to implement this approach are described.

  1. Galactic cosmic radiation doses to astronauts outside the magnetosphere

    SciTech Connect

    Letaw, J.R.

    1987-12-06

    The dose and dose equivalent from galactic cosmic radiation outside the magnetosphere were computed. The principal radiation components considered include primary cosmic rays, spallation fragments of the heavy ions, and secondary products (protons, neutrons, alphas, and recoil nuclei) from interactions in tissue. Three mission environments were considered: free space, the lunar surface, and the martian surface. The annual dose equivalents to the blood-forming organs in these environments are approximately 500 mSv, 250 mSv, and 120 mSv, respectively (1 mSv = 0.1 rem). The dose on the lunar surface is one-half of free space because there is only a single hemisphere of exposure. The dose on the martian surface is half again the dose on the moon because of the shielding provided by a thin, carbon dioxide atmosphere. Dose versus aluminum shielding thickness functions have been computed for the free space exposure. Galactic cosmic radiation is energetic and highly penetrating. 30 cm of aluminum shielding reduces the dose equivalent 25% to 40% (depending on the phase of the solar cycle). Aiming for conformity with the draft NCRP annual dose limit for space station crew members, which is 500 mSv/yr, we recommend 7.5 cm of aluminum shielding in all habitable areas of spacecraft designed for long-duration missions outside Earth's magnetosphere. This shielding thickness reduces the galactic cosmic ray dose and diminishes the risk to astronauts from energetic particle events.

  2. High and Low Doses of Ionizing Radiation Induce Different Secretome Profiles in a Human Skin Model

    SciTech Connect

    Zhang, Qibin; Matzke, Melissa M.; Schepmoes, Athena A.; Moore, Ronald J.; Webb-Robertson, Bobbie-Jo M.; Hu, Zeping; Monroe, Matthew E.; Qian, Weijun; Smith, Richard D.; Morgan, William F.

    2014-03-18

    It is postulated that secreted soluble factors are important contributors of bystander effect and adaptive responses observed in low dose ionizing radiation. Using multidimensional liquid chromatography-mass spectrometry based proteomics, we quantified the changes of skin tissue secretome – the proteins secreted from a full thickness, reconstituted 3-dimensional skin tissue model 48 hr after exposure to 3, 10 and 200 cGy of X-rays. Overall, 135 proteins showed statistical significant difference between the sham (0 cGy) and any of the irradiated groups (3, 10 or 200 cGy) on the basis of Dunnett adjusted t-test; among these, 97 proteins showed a trend of downregulation and 9 proteins showed a trend of upregulation with increasing radiation dose. In addition, there were 21 and 8 proteins observed to have irregular trends with the 10 cGy irradiated group either having the highest or the lowest level among all three radiated doses. Moreover, two proteins, carboxypeptidase E and ubiquitin carboxyl-terminal hydrolase isozyme L1 were sensitive to ionizing radiation, but relatively independent of radiation dose. Conversely, proteasome activator complex subunit 2 protein appeared to be sensitive to the dose of radiation, as rapid upregulation of this protein was observed when radiation doses were increased from 3, to 10 or 200 cGy. These results suggest that different mechanisms of action exist at the secretome level for low and high doses of ionizing radiation.

  3. Awakening the immune system with radiation: Optimal dose and fractionation.

    PubMed

    Gandhi, Saumil J; Minn, Andy J; Vonderheide, Robert H; Wherry, E John; Hahn, Stephen M; Maity, Amit

    2015-11-28

    The importance of ionizing radiation has historically been limited to achieving local control of tumor cells. However, emerging evidence over the last decade suggests an increasingly important role for radiation in amplifying the antitumor immune response elicited by immunomodulatory agents. Combination of radiation with immunotherapy has been shown to elicit powerful systemic responses in several pre-clinical tumor models. Additionally, recent clinical observations support the use of radiation therapy for augmenting antitumor immunity in the metastatic setting. However, radiation dose and fractionation schedules for optimal synergy between radiotherapy and immunotherapy are not well defined. Here we review pre-clinical and clinical data relating to radiation dose and fractionation in the setting of immunotherapy and discuss optimal strategies for combining the two therapies. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. [Multislice CT in a diagnostic imaging department: radiation doses delivered in 1 year.].

    PubMed

    Salmerón, Isabel; Calzado, Alfonso; Ruiz-López, Laura; Alonso, Verónica; Cordeiro, César; Fraile, Eduardo

    2009-01-01

    To determine the usage of CT in our diagnostic imaging department and the dose of radiation CT delivered to patients. We carried out two studies, a retrospective study on the administrative data from one year and a prospective study over one month, to determine the amount of activity of the two multislice CT scanners in our department. We recorded the total number of examinations, the different types of examination performed, and the age distributions of the patients examined. We used these data and the results of dosimetric measurements to estimate the typical radiation dose for each type of examination, its contribution to the collective radiation dose, and the total collective radiation dose from CT examinations at our hospital. The retrospective study found that 15038 examinations were performed in 12678 patients in one year. The most common CT examinations were cranial (38.2%), abdomen-pelvis (17.5%), chest-abdomen (11.7%), chest (9.3%), and lumbar-sacral spine (6.8%). Some protocols used doses of radiation that were higher than those recommended by European experts. The total collective dose of radiation delivered to patients at our hospital by CT was estimated at 70 person.Sv. Abdomen-pelvis examinations contributed 31% of the total dose. This study has provided detailed knowledge about the use of CT in our diagnostic imaging department, about the dose of radiation delivered, and about possibilities for improving the use of our CT scanners.

  5. Does clinical indication play a role in CT radiation dose in pediatric patients?

    PubMed

    Triantopoulou, Sotiria; Tsapaki, Virginia

    2017-09-01

    The purpose of this study was to identify the main pathologies for which CT is applied on pediatric patients and the related radiation doses as reported in the literature in order to facilitate justification and CT optimization. A critical analysis of a literature review was performed. Different search engines were used such as PubMed, Google Scholar and Science Direct. Various terms and keywords were used to locate pertinent articles such as Pediatric, Computed tomography, Radiation Dose, Organ dose, Effective dose. The results showed that the main pathologies for which CT is applied are: Crohn's disease, hydrocephalus, cystic fibrosis and pediatric malignancies-mainly lymphoma. The related radiation dose data are extremely scarce and are in the range of 3.48-17.56, 0.2-15.3mSv, 0.14-6.20mSv, and 2.8-518.0mSv, respectively. The radiation doses reported are high especially in pediatric oncology. Pediatric patients with malignancies are those exposed to the higher levels of radiation during CT imaging. Literature is lacking reporting of dose in Pediatric CT imaging. More studies need to be realized for the determination of radiation dose in those patients. Special protocols need to be recommended in order to reduce the exposure of children in radiation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  6. Method for inserting noise in digital mammography to simulate reduction in radiation dose

    NASA Astrophysics Data System (ADS)

    Borges, Lucas R.; de Oliveira, Helder C. R.; Nunes, Polyana F.; Vieira, Marcelo A. C.

    2015-03-01

    The quality of clinical x-ray images is closely related to the radiation dose used in the imaging study. The general principle for selecting the radiation is ALARA ("as low as reasonably achievable"). The practical optimization, however, remains challenging. It is well known that reducing the radiation dose increases the quantum noise, which could compromise the image quality. In order to conduct studies about dose reduction in mammography, it would be necessary to acquire repeated clinical images, from the same patient, with different dose levels. However, such practice would be unethical due to radiation related risks. One solution is to simulate the effects of dose reduction in clinical images. This work proposes a new method, based on the Anscombe transformation, which simulates dose reduction in digital mammography by inserting quantum noise into clinical mammograms acquired with the standard radiation dose. Thus, it is possible to simulate different levels of radiation doses without exposing the patient to new levels of radiation. Results showed that the achieved quality of simulated images generated with our method is the same as when using other methods found in the literature, with the novelty of using the Anscombe transformation for converting signal-independent Gaussian noise into signal-dependent quantum noise.

  7. Malignant melanoma of the tongue following low-dose radiation

    SciTech Connect

    Kalemeris, G.C.; Rosenfeld, L.; Gray, G.F. Jr.; Glick, A.D.

    1985-03-01

    A 47-year-old man had a spindly malignant melanoma of the tongue many years after low-dose radiation therapy for lichen planus. To our knowledge, only 12 melanomas of the tongue have been reported previously, and in none of these was radiation documented.

  8. Perception of Radiation Risk by Japanese Radiation Specialists Evaluated as a Safe Dose Before the Fukushima Nuclear Accident.

    PubMed

    Miura, Miwa; Ono, Koji; Yamauchi, Motohiro; Matsuda, Naoki

    2016-06-01

    From October to December 2010, just before the radiological accident at the Fukushima Daiichi nuclear power plant, 71 radiation professionals from radiation facilities in Japan were asked what they considered as a "safe dose" of radiation for themselves, their partners, parents, children, siblings, and friends. Although the 'safe dose' they noted varied widely, from less than 1 mSv y to more than 100 mSv y, the average dose was 35.6 mSv y, which is around the middle point between the legal exposure dose limits for the annual average and for any single year. Similar results were obtained from other surveys of members of the Japan Radioisotope Association (36.9 mSv y) and of the Oita Prefectural Hospital (36.8 mSv y). Among family members and friends, the minimum average "safe" dose was 8.5 mSv y for children, for whom 50% of the responders claimed a "safe dose" of less than 1 mSv. Gender, age and specialty of the radiation professional also affected their notion of a "safe dose." These findings suggest that the perception of radiation risk varies widely even for radiation professionals and that the legal exposure dose limits derived from regulatory science may act as an anchor of safety. The different levels of risk perception for different target groups among radiation professionals appear similar to those in the general population. The gap between these characteristics of radiation professionals and the generally accepted picture of radiation professionals might have played a role in the state of confusion after the radiological accident.

  9. Dose-dependent radiation-induced hypotension in the canine

    SciTech Connect

    Cockerham, L.G.; Hampton, J.D.; Doyle, T.F.

    1986-01-01

    Radiation-induced early transient incapacitation (ETI) is often accompanied by severe systemic hypotension. However, postradiation hypotension does not occur with equal frequency in all species and is not reported with consistency in the canine. In an attempt to clarify the differences in reported canine post-radiation blood pressures, canine systemic blood pressures were determined both before and after exposure to gamma radiation of either 80 or 100 Gy. Data obtained from six sham-radiated beagles and 12 radiated beagles indicated that 100-Gy, whole-body, gamma radiation produced a decrease in systemic mean blood pressure while 80-Gy, whole-body, gamma radiation did not. Analysis of this data could be consistent with a quantal response to a gamma radiation dose between 80 Gy and 100 Gy.

  10. The susceptibility of TaOx-based memristors to high dose rate ionizing radiation and total ionizing dose

    DOE PAGES

    McLain, Michael Lee; Sheridan, Timothy J.; Hjalmarson, Harold Paul; ...

    2014-11-11

    This paper investigates the effects of high dose rate ionizing radiation and total ionizing dose (TID) on tantalum oxide (TaOx) memristors. Transient data were obtained during the pulsed exposures for dose rates ranging from approximately 5.0 ×107 rad(Si)/s to 4.7 ×108 rad(Si)/s and for pulse widths ranging from 50 ns to 50 μs. The cumulative dose in these tests did not appear to impact the observed dose rate response. Static dose rate upset tests were also performed at a dose rate of ~3.0 ×108 rad(Si)/s. This is the first dose rate study on any type of memristive memory technology. Inmore » addition to assessing the tolerance of TaOx memristors to high dose rate ionizing radiation, we also evaluated their susceptibility to TID. The data indicate that it is possible for the devices to switch from a high resistance off-state to a low resistance on-state in both dose rate and TID environments. The observed radiation-induced switching is dependent on the irradiation conditions and bias configuration. Furthermore, the dose rate or ionizing dose level at which a device switches resistance states varies from device to device; the enhanced susceptibility observed in some devices is still under investigation. As a result, numerical simulations are used to qualitatively capture the observed transient radiation response and provide insight into the physics of the induced current/voltages.« less

  11. Effects Of Dose Rates On Radiation Damage In CMOS Parts

    NASA Technical Reports Server (NTRS)

    Goben, Charles A.; Coss, James R.; Price, William E.

    1990-01-01

    Report describes measurements of effects of ionizing-radiation dose rate on consequent damage to complementary metal oxide/semiconductor (CMOS) electronic devices. Depending on irradiation time and degree of annealing, survivability of devices in outer space, or after explosion of nuclear weapons, enhanced. Annealing involving recovery beyond pre-irradiation conditions (rebound) detrimental. Damage more severe at lower dose rates.

  12. Radiation Dose-Volume Effects in the Esophagus

    SciTech Connect

    Werner-Wasik, Maria; Yorke, Ellen; Deasy, Joseph; Nam, Jiho; Marks, Lawrence B.

    2010-03-01

    Publications relating esophageal radiation toxicity to clinical variables and to quantitative dose and dose-volume measures derived from three-dimensional conformal radiotherapy for non-small-cell lung cancer are reviewed. A variety of clinical and dosimetric parameters have been associated with acute and late toxicity. Suggestions for future studies are presented.

  13. Fetal radiation dose in computed tomography.

    PubMed

    Kelaranta, Anna; Kaasalainen, Touko; Seuri, Raija; Toroi, Paula; Kortesniemi, Mika

    2015-07-01

    The connection between recorded volumetric CT dose index (CTDI vol) and determined mean fetal dose (Df) was examined from metal-oxide-semiconductor field-effect transistor dose measurements on an anthropomorphic female phantom in four stages of pregnancy in a 64-slice CT scanner. Automated tube current modulation kept the mean Df fairly constant through all pregnancy stages in trauma (4.4-4.9 mGy) and abdomino-pelvic (2.1-2.4 mGy) protocols. In pulmonary angiography protocol, the mean Df increased exponentially as the distance from the end of the scan range decreased (0.01-0.09 mGy). For trauma protocol, the relative mean Df as a function of gestational age were in the range 0.80-0.97 compared with the mean CTDI vol. For abdomino-pelvic protocol, the relative mean Df was 0.57-0.79 and for pulmonary angiography protocol, 0.01-0.05 compared with the mean CTDI vol, respectively. In conclusion, if the fetus is in the primary beam, the CTDI vol can be used as an upper estimate of the fetal dose. If the fetus is not in the primary beam, the fetal dose can be estimated by considering also the distance of the fetus from the scan range.

  14. Flight attendant radiation dose from solar particle events.

    PubMed

    Anderson, Jeri L; Mertens, Christopher J; Grajewski, Barbara; Luo, Lian; Tseng, Chih-Yu; Cassinelli, Rick T

    2014-08-01

    Research has suggested that work as a flight attendant may be related to increased risk for reproductive health effects. Air cabin exposures that may influence reproductive health include radiation dose from galactic cosmic radiation and solar particle events. This paper describes the assessment of radiation dose accrued during solar particle events as part of a reproductive health study of flight attendants. Solar storm data were obtained from the National Oceanic and Atmospheric Administration Space Weather Prediction Center list of solar proton events affecting the Earth environment to ascertain storms relevant to the two study periods (1992-1996 and 1999-2001). Radiation dose from exposure to solar energetic particles was estimated using the NAIRAS model in conjunction with galactic cosmic radiation dose calculated using the CARI-6P computer program. Seven solar particle events were determined to have potential for significant radiation exposure, two in the first study period and five in the second study period, and over-lapped with 24,807 flight segments. Absorbed (and effective) flight segment doses averaged 6.5 μGy (18 μSv) and 3.1 μGy (8.3 μSv) for the first and second study periods, respectively. Maximum doses were as high as 440 μGy (1.2 mSv) and 20 flight segments had doses greater than 190 μGy (0.5 mSv). During solar particle events, a pregnant flight attendant could potentially exceed the equivalent dose limit to the conceptus of 0.5 mSv in a month recommended by the National Council on Radiation Protection and Measurements.

  15. Intensity Modulated Radiation Therapy With Dose Painting to Treat Rhabdomyosarcoma

    SciTech Connect

    Yang, Joanna C.; Dharmarajan, Kavita V.; Wexler, Leonard H.; La Quaglia, Michael P.; Happersett, Laura; Wolden, Suzanne L.

    2012-11-01

    Purpose: To examine local control and patterns of failure in rhabdomyosarcoma patients treated with intensity modulated radiation therapy (RT) with dose painting (DP-IMRT). Patients and Methods: A total of 41 patients underwent DP-IMRT with chemotherapy for definitive treatment. Nineteen also underwent surgery with or without intraoperative RT. Fifty-six percent had alveolar histologic features. The median interval from beginning chemotherapy to RT was 17 weeks (range, 4-25). Very young children who underwent second-look procedures with or without intraoperative RT received reduced doses of 24-36 Gy in 1.4-1.8-Gy fractions. Young adults received 50.4 Gy to the primary tumor and lower doses of 36 Gy in 1.8-Gy fractions to at-risk lymph node chains. Results: With 22 months of median follow-up, the actuarial local control rate was 90%. Patients aged {<=}7 years who received reduced overall and fractional doses had 100% local control, and young adults had 79% (P=.07) local control. Three local failures were identified in young adults whose primary target volumes had received 50.4 Gy in 1.8-Gy fractions. Conclusions: DP-IMRT with lower fractional and cumulative doses is feasible for very young children after second-look procedures with or without intraoperative RT. DP-IMRT is also feasible in adolescents and young adults with aggressive disease who would benefit from prophylactic RT to high-risk lymph node chains, although dose escalation might be warranted for improved local control. With limited follow-up, it appears that DP-IMRT produces local control rates comparable to those of sequential IMRT in patients with rhabdomyosarcoma.

  16. Radiation dose and image quality for paediatric interventional cardiology.

    PubMed

    Vano, E; Ubeda, C; Leyton, F; Miranda, P

    2008-08-07

    Radiation dose and image quality for paediatric protocols in a biplane x-ray system used for interventional cardiology have been evaluated. Entrance surface air kerma (ESAK) and image quality using a test object and polymethyl methacrylate (PMMA) phantoms have been measured for the typical paediatric patient thicknesses (4-20 cm of PMMA). Images from fluoroscopy (low, medium and high) and cine modes have been archived in digital imaging and communications in medicine (DICOM) format. Signal-to-noise ratio (SNR), figure of merit (FOM), contrast (CO), contrast-to-noise ratio (CNR) and high contrast spatial resolution (HCSR) have been computed from the images. Data on dose transferred to the DICOM header have been used to test the values of the dosimetric display at the interventional reference point. ESAK for fluoroscopy modes ranges from 0.15 to 36.60 microGy/frame when moving from 4 to 20 cm PMMA. For cine, these values range from 2.80 to 161.10 microGy/frame. SNR, FOM, CO, CNR and HCSR are improved for high fluoroscopy and cine modes and maintained roughly constant for the different thicknesses. Cumulative dose at the interventional reference point resulted 25-45% higher than the skin dose for the vertical C-arm (depending of the phantom thickness). ESAK and numerical image quality parameters allow the verification of the proper setting of the x-ray system. Knowing the increases in dose per frame when increasing phantom thicknesses together with the image quality parameters will help cardiologists in the good management of patient dose and allow them to select the best imaging acquisition mode during clinical procedures.

  17. Radiation dose and image quality for paediatric interventional cardiology

    NASA Astrophysics Data System (ADS)

    Vano, E.; Ubeda, C.; Leyton, F.; Miranda, P.

    2008-08-01

    Radiation dose and image quality for paediatric protocols in a biplane x-ray system used for interventional cardiology have been evaluated. Entrance surface air kerma (ESAK) and image quality using a test object and polymethyl methacrylate (PMMA) phantoms have been measured for the typical paediatric patient thicknesses (4-20 cm of PMMA). Images from fluoroscopy (low, medium and high) and cine modes have been archived in digital imaging and communications in medicine (DICOM) format. Signal-to-noise ratio (SNR), figure of merit (FOM), contrast (CO), contrast-to-noise ratio (CNR) and high contrast spatial resolution (HCSR) have been computed from the images. Data on dose transferred to the DICOM header have been used to test the values of the dosimetric display at the interventional reference point. ESAK for fluoroscopy modes ranges from 0.15 to 36.60 µGy/frame when moving from 4 to 20 cm PMMA. For cine, these values range from 2.80 to 161.10 µGy/frame. SNR, FOM, CO, CNR and HCSR are improved for high fluoroscopy and cine modes and maintained roughly constant for the different thicknesses. Cumulative dose at the interventional reference point resulted 25-45% higher than the skin dose for the vertical C-arm (depending of the phantom thickness). ESAK and numerical image quality parameters allow the verification of the proper setting of the x-ray system. Knowing the increases in dose per frame when increasing phantom thicknesses together with the image quality parameters will help cardiologists in the good management of patient dose and allow them to select the best imaging acquisition mode during clinical procedures.

  18. Results from the Martian Radiation Environment Experiment

    NASA Astrophysics Data System (ADS)

    Zeitlin, C.; Cleghorn, T. F.; Cucinotta, F. A.; Saganti, P.

    2003-12-01

    Ionizing radiation in space presents a potentially serious health hazard to astronauts on long-duration missions outside the geomagnetosphere. As a precursor to possible human exploration, the Martian Radiation Environment Experiment, MARIE, is returning the first detailed radiation data from Mars. MARIE is designed to measure the nearly constant flux of energetic Galactic Cosmic Rays (GCR) and intermittent Solar Particle Events (SPE). Despite considerable uncertainties in the normalization of MARIE data, comparisons to model calculations show good agreement, well within the estimated errors. The radiation dose equivalent on Mars from GCR is predicted to be 0.2 - 0.3 Sieverts/yr. (This is approximately 1000 times higher than the cosmic ray dose received on Earth.) In Mars orbit, over the first 16 months of operation, MARIE data show an annual dose equivalent of 0.4 +- 0.1 Sv/yr. That the measured rate is higher than the calculation is expected, since in orbit there is a contribution from low-energy particles that do not survive transport through the atmosphere. Additionally, SPE during this period have contributed about 0.04 Sv/yr to the average annual dose equivalent, a figure that can vary substantially over the course of the solar cycle. The implications of these data for human exploration will be discussed.

  19. Radiation Dose-Response Relationships and Risk Assessment

    SciTech Connect

    Strom, Daniel J.

    2005-07-05

    The notion of a dose-response relationship was probably invented shortly after the discovery of poisons, the invention of alcoholic beverages, and the bringing of fire into a confined space in the forgotten depths of ancient prehistory. The amount of poison or medicine ingested can easily be observed to affect the behavior, health, or sickness outcome. Threshold effects, such as death, could be easily understood for intoxicants, medicine, and poisons. As Paracelsus (1493-1541), the 'father' of modern toxicology said, 'It is the dose that makes the poison.' Perhaps less obvious is the fact that implicit in such dose-response relationships is also the notion of dose rate. Usually, the dose is administered fairly acutely, in a single injection, pill, or swallow; a few puffs on a pipe; or a meal of eating or drinking. The same amount of intoxicants, medicine, or poisons administered over a week or month might have little or no observable effect. Thus, before the discovery of ionizing radiation in the late 19th century, toxicology ('the science of poisons') and pharmacology had deeply ingrained notions of dose-response relationships. This chapter demonstrates that the notion of a dose-response relationship for ionizing radiation is hopelessly simplistic from a scientific standpoint. While useful from a policy or regulatory standpoint, dose-response relationships cannot possibly convey enough information to describe the problem from a quantitative view of radiation biology, nor can they address societal values. Three sections of this chapter address the concepts, observations, and theories that contribute to the scientific input to the practice of managing risks from exposure to ionizing radiation. The presentation begins with irradiation regimes, followed by responses to high and low doses of ionizing radiation, and a discussion of how all of this can inform radiation risk management. The knowledge that is really needed for prediction of individual risk is presented

  20. Radiation dose to the lens and cataract formation

    SciTech Connect

    Henk, J.M.; Whitelocke, R.A.F.; Warrington, A.P.; Bessell, E.M. )

    1993-04-02

    The purpose of this work was to determine the radiation tolerance of the lens of the eye and the incidence of radiation-induced lens changes in patients treated by fractionated supervoltage radiation therapy for orbital tumors. Forty patients treated for orbital lymphoma and pseudotumor with tumor doses of 20--40 Gy were studied. The lens was partly shielded using lead cylinders in most cases. The dose to the germinative zone of the lens was estimated by measurements in a tissue equivalent phantom using both film densitometry and thermoluminescent dosimetry. Opthalmological examination was performed at 6 monthly intervals after treatment. The lead shield was found to reduce the dose to the germinative zone of the lens to between 36--50% of the tumor dose for Cobalt beam therapy, and to between 11--18% for 5 MeV x-rays. Consequently, the lens doses were in the range 4.5--30 Gy in 10--20 fractions. Lens opacities first appeared from between 3 and 9 years after irradiation. Impairment of visual acuity ensued in 74% of the patients who developed lens opacities. The incidence of lens changes was strongly dose-related. None was seen after doses of 5 Gy or lower, whereas doses of 16.5 Gy or higher were all followed by lens opacities which impaired visual acuity. The largest number of patients received a maximum lens dose of 15 Gy; in this group the actuarial incidence of lens opacities at 8 years was 57% with visual impairment in 38%. The adult lens can tolerate a total dose of 5 Gy during a fractionated course of supervoltage radiation therapy without showing any changes. Doses of 16.5 Gy or higher will almost invariably lead to visual impairment. The dose which causes a 50% probability of visual impairment is approximately 15 Gy. 10 refs., 4 figs., 1 tab.

  1. Some cosmic radiation dose measurements aboard flights connecting Zagreb Airport.

    PubMed

    Vuković, B; Radolić, V; Lisjak, I; Vekić, B; Poje, M; Planinić, J

    2008-02-01

    When primary particles from space, mainly protons, enter the atmosphere, they produce interactions with air nuclei, and cosmic-ray showers are induced. The radiation field at aircraft altitude is complex, with different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The non-neutron component of cosmic radiation dose aboard A320 and ATR40 aircraft was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter; the neutron dose was measured with the neutron dosimeter consisted of LR-115 track detector and boron foil BN-1 or 10B converter. The estimated occupational effective dose for the aircraft crew (A320) working 500 h per year was 1.64 mSv. Another experiment was performed at the flights Zagreb-Paris-Buenos Aires and reversely, when one measured non-neutron cosmic radiation dose; for 26.7 h of flight, the MINI 6100 dosimeter gave an average dose rate of 2.3 microSv/h and the TLD dosimeter registered the dose equivalent of 75 microSv or the average dose rate of 2.7 microSv/h; the neutron dosimeter gave the dose rate of 2.4 microSv/h. In the same month, February 2005, a traveling to Japan (24-h-flight: Zagreb-Frankfurt-Tokyo and reversely) and the TLD-100 measurement showed the average dose rate of 2.4microSv/h; the neutron dosimeter gave the dose rate of 2.5 microSv/h. Comparing dose rates of the non-neutron component (low LET) and the neutron one (high LET) of the radiation field at the aircraft flight level, we could conclude that the neutron component carried about 50% of the total dose, that was near other known data.

  2. Radiation Dose from Lunar Neutron Albedo

    NASA Technical Reports Server (NTRS)

    Adams, J. H., Jr.; Bhattacharya, M.; Lin, Zi-Wei; Pendleton, G.

    2006-01-01

    The lunar neutron albedo from thermal energies to 8 MeV was measured on the Lunar Prospector Mission in 1998-1999. Using GEANT4 we have calculated the neutron albedo due to cosmic ray bombardment of the moon and found a good-agreement with the measured fast neutron spectra. We then calculated the total effective dose from neutron albedo of all energies, and made comparisons with the effective dose contributions from both galactic cosmic rays and solar particle events to be expected on the lunar surface.

  3. Radiation doses in Sweden after the Chernobyl accident

    SciTech Connect

    Haegg, N.C.

    1989-01-01

    The reactor accident at Chernobyl led to releases of large amounts of radioactive matter that was spread over the world and particularly over Europe. The radioactive material released gave rise to radiation doses originating from inhalation, external radiation from both the passing cloud and radioactive material deposited on the ground, and internal irradiation from consumption of food stuffs. This paper summarizes the consequences in Sweden after the Chernobyl accident. The emphasis is mainly on radiation doses received by the public and the long-term effects in Sweden.

  4. Acute radiation enteritis caused by dose-dependent radiation exposure in dogs: experimental research.

    PubMed

    Xu, Wenda; Chen, Jiang; Xu, Liu; Li, Hongyu; Guo, Xiaozhong

    2014-12-01

    Accidental or intended radiation exposure in mass casualty settings presents a serious and on-going threat. The development of mitigating and treating agents requires appropriate animal models. Unfortunately, the majority of research on radiation enteritis in animals has lacked specific assessments and targeted therapy. Our study showed beagle dogs, treated by intensity-modulated radiation therapy (IMRT) for abdominal irradiation, were administered single X-ray doses of 8-30 Gy. The degree of intestinal tract injury for all of the animals after radiation exposure was evaluated with regard to clinical syndrome, endoscopic findings, histological features, and intestinal function. The range of single doses (8 Gy, 10-14 Gy, and 16-30 Gy) represented the degree of injury (mild, moderate, and severe, respectively). Acute radiation enteritis included clinical syndrome with fever, vomiting, diarrhea, hemafecia, and weight loss; typical endoscopic findings included edema, bleeding, mucosal abrasions, and ulcers; and intestinal biopsy results revealed mucosal necrosis, erosion, and loss, inflammatory cell infiltration, hemorrhage, and congestion. Changes in serum diamine oxides (DAOs) and d-xylose represented intestinal barrier function and absorption function, respectively, and correlated with the extent of damage (P < 0.05 and P < 0.05, respectively). We successfully developed a dog model of acute radiation enteritis, thus obtaining a relatively objective evaluation of intestinal tract injury based on clinical performance and laboratory examination. The method of assessment of the degree of intestinal tract injury after abdominal irradiation could be beneficial in the development of novel and effective therapeutic strategies for acute radiation enteritis.

  5. Effect of real-time radiation dose feedback on pediatric interventional radiology staff radiation exposure.

    PubMed

    Racadio, John; Nachabe, Rami; Carelsen, Bart; Racadio, Judy; Hilvert, Nicole; Johnson, Neil; Kukreja, Kamlesh; Patel, Manish

    2014-01-01

    To measure and compare individual staff radiation dose levels during interventional radiologic (IR) procedures with and without real-time feedback to evaluate whether it has any impact on staff radiation dose. A prospective trial was performed in which individuals filling five different staff roles wore radiation dosimeters during all IR procedures during two phases: a 12-week "closed" phase (measurements recorded but display was off, so no feedback was provided) and a 17-week "open" phase (display was on and provided real-time feedback). Radiation dose rates were recorded and compared by Mann-Whitney U test. There was no significant difference in median procedure time, fluoroscopy time, or patient dose (dose-area product normalized to fluoroscopy time) between the two phases. Overall, the median staff dose was lower in the open phase (0.56 µSv/min of fluoroscopy time) than in the closed phase (3.01 µSv/min; P < .05). The IR attending physician dose decreased significantly for procedures for which the physicians were close to the patient, but not for ones for which they were far away. A radiation dose monitoring system that provides real-time feedback to the interventional staff can significantly reduce radiation exposure to the primary operator, most likely by increasing staff compliance with use of radiation protection equipment and dose reduction techniques. Copyright © 2014. Published by Elsevier Inc.

  6. Radiation dose reduction in chest CT--review of available options.

    PubMed

    Kubo, Takeshi; Ohno, Yoshiharu; Kauczor, Hans Ulrich; Hatabu, Hiroto

    2014-10-01

    Computed tomography currently accounts for the majority of radiation exposure related to medical imaging. Although technological improvement of CT scanners has reduced the radiation dose of individual examinations, the benefit was overshadowed by the rapid increase in the number of CT examinations. Radiation exposure from CT examination should be kept as low as reasonably possible for patient safety. Measures to avoid inappropriate CT examinations are needed. Principles and information on radiation dose reduction in chest CT are reviewed in this article. The reduction of tube current and tube potential are the mainstays of dose reduction methods. Study results indicate that routine protocols with reduced tube current are feasible with diagnostic results comparable to conventional standard dose protocols. Tube current adjustment is facilitated by the advent of automatic tube current modulation systems by setting the appropriate image quality level for the purpose of the examination. Tube potential reduction is an effective method for CT pulmonary angiography. Tube potential reduction often requires higher tube current for satisfactory image quality, but may still contribute to significant radiation dose reduction. Use of lower tube potential also has considerable advantage for smaller patients. Improvement in image production, especially the introduction of iterative reconstruction methods, is expected to lower radiation dose significantly. Radiation dose reduction in CT is a multifaceted issue. Understanding these aspects leads to an optimal solution for various indications of chest CT. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Radiation Dose-Volume Effects in the Heart

    SciTech Connect

    Gagliardi, Giovanna; Constine, Louis S.; Moiseenko, Vitali; Correa, Candace; Pierce, Lori J.; Allen, Aaron M.; Marks, Lawrence B.

    2010-03-01

    The literature is reviewed to identify the main clinical and dose-volume predictors for acute and late radiation-induced heart disease. A clear quantitative dose and/or volume dependence for most cardiac toxicity has not yet been shown, primarily because of the scarcity of the data. Several clinical factors, such as age, comorbidities and doxorubicin use, appear to increase the risk of injury. The existing dose-volume data is presented, as well as suggestions for future investigations to better define radiation-induced cardiac injury.

  8. Total-dose radiation hardness assurance for space electronics

    SciTech Connect

    Winokur, P.S.; Fleetwood, D.M. )

    1991-01-05

    An improved standard total-dose test method is described to qualify electronics for a low-dose-rate radiation environment typical of space systems. The method consists of {sup 60}Co irradiation at a dose rate of 1--3 Gy(Si)/s (100--300 rad(Si)/s) and a subsequent 373 K (100 {degree}C) bake. New initatives in radiation hardness assurance are also briefly discussed, including the Qualified Manufactures List (QML) test methodology and the possible use of 1/f noise measurements as a nondestructive screen for oxide-trap charge related failure.

  9. A CONCEPTUAL FRAMEWORK FOR MANAGING RADIATION DOSE TO PATIENTS IN DIAGNOSTIC RADIOLOGY USING REFERENCE DOSE LEVELS.

    PubMed

    Almén, Anja; Båth, Magnus

    2016-06-01

    The overall aim of the present work was to develop a conceptual framework for managing radiation dose in diagnostic radiology with the intention to support optimisation. An optimisation process was first derived. The framework for managing radiation dose, based on the derived optimisation process, was then outlined. The outset of the optimisation process is four stages: providing equipment, establishing methodology, performing examinations and ensuring quality. The optimisation process comprises a series of activities and actions at these stages. The current system of diagnostic reference levels is an activity in the last stage, ensuring quality. The system becomes a reactive activity only to a certain extent engaging the core activity in the radiology department, performing examinations. Three reference dose levels-possible, expected and established-were assigned to the three stages in the optimisation process, excluding ensuring quality. A reasonably achievable dose range is also derived, indicating an acceptable deviation from the established dose level. A reasonable radiation dose for a single patient is within this range. The suggested framework for managing radiation dose should be regarded as one part of the optimisation process. The optimisation process constitutes a variety of complementary activities, where managing radiation dose is only one part. This emphasises the need to take a holistic approach integrating the optimisation process in different clinical activities.

  10. Individual and collective doses from cosmic radiation in Ireland.

    PubMed

    Colgan, P A; Synnott, H; Fenton, D

    2007-01-01

    This paper assesses the individual and collective doses in Ireland due to cosmic radiation. Information on the exposure to cosmic radiation at ground level is reviewed and published data on the frequency of routes flown by Irish residents is used to calculate the dose due to air travel. Occupational exposure of aircrew is also evaluated. Experimental data on cosmic radiation exposure at ground level is in good agreement with international estimates and the average individual dose is calculated as 300 microSv annually. Published data on international air travel by Irish residents shows a 50% increase in the number of flights taken between 2001 and 2005. This increase is primarily on short-haul flights to Europe, but there have been significant percentage increases in all long-haul flights, with the exception of flights to Africa. The additional per capita dose due to air travel is estimated to be 45 muSv, of which 51% is accumulated on European routes and 34% on routes to the United States. Exposure of aircrew to cosmic radiation is now controlled by legislation and all airlines holding an Air Operator's Certificate issued by the Irish Aviation Authority are required to report annually the doses received by their employees in the previous year. There has been a 75% increase in the number of aircrew receiving doses >1 mSv since 2002. In 2004 and 2005 the average individual doses received by Irish aircrew were 1.8 and 2.0, mSv, respectively. The corresponding per caput dose for the entire population is <3 muSv. While this is low compared with the per caput doses from other sources of cosmic radiation, aircrew exposure represents a higher collective dose than any other identified group of exposed workers in Ireland.

  11. Cytokine profile of breast cell lines after different radiation doses.

    PubMed

    Bravatà, Valentina; Minafra, Luigi; Forte, Giusi Irma; Cammarata, Francesco Paolo; Russo, Giorgio; Di Maggio, Federica Maria; Augello, Giuseppa; Lio, Domenico; Gilardi, Maria Carla

    2017-09-01

    Ionizing radiation (IR) treatment activates inflammatory processes causing the release of a great amount of molecules able to affect the cell survival. The aim of this study was to analyze the cytokine signature of conditioned medium produced by non-tumorigenic mammary epithelial cell line MCF10A, as well as MCF7 and MDA-MB-231 breast cancer cell lines, after single high doses of IR in order to understand their role in high radiation response. We performed a cytokine profile of irradiated conditioned media of MCF10A, MCF7 and MDA-MB-231 cell lines treated with 9 or 23 Gy, by Luminex and ELISA analyses. Overall, our results show that both 9 Gy and 23 Gy of IR induce the release within the first 72 h of cytokines and growth factors potentially able to influence the tumor outcome, with a dose-independent and cell-line dependent signature. Moreover, our results show that the cell-senescence phenomenon does not correlate with the amount of 'senescence-associated secretory phenotype' (SASP) molecules released in media. Thus, additional mechanisms are probably involved in this process. These data open the possibility to evaluate cytokine profile as useful marker in modulating the personalized radiotherapy in breast cancer care.

  12. Radiation Doses to Hanford Workers from Natural Potassium-40

    SciTech Connect

    Strom, Daniel J.; Lynch, Timothy P.; Weier, Dennis R.

    2009-02-01

    The chemical element potassium is an essential mineral in people and is subject to homeostatic regulation. Natural potassium comprises three isotopes, 39K, 40K, and 41K. Potassium-40 is radioactive, with a half life of 1.248 billion years. In most transitions, it emits a β particle with a maximum energy of 0.560 MeV, and sometimes a gamma photon of 1.461 MeV. Because it is ubiquitous, 40K produces radiation dose to all human beings. This report contains the results of new measurements of 40K in 248 adult females and 2,037 adult males performed at the Department of Energy Hanford Site in 2006 and 2007. Potassium concentrations diminish with age, are generally lower in women than in men, and decrease with body mass index (BMI). The average annual effective dose from 40K in the body is 0.149 mSv y-1 for men and 0.123 mSv y-1 women respectively. Averaged over both men and women, the average effective dose per year is 0.136 mSv y-1. Calculated effective doses range from 0.069 to 0.243 mSv y-1 for adult males, and 0.067 to 0.203 mSv y-1 for adult females, a roughly three-fold variation for each gender. The need for dosimetric phantoms with a greater variety of BMI values should be investigated. From our data, it cannot be determined whether the potassium concentration in muscle in people with large BMI values differs from that in people with small BMI values. Similarly, it would be important to know the potassium concentration in other soft tissues, since much of the radiation dose is due to beta radiation, in which the source and target tissues are the same. These uncertainties should be evaluated to determine their consequences for dosimetry.

  13. High and low dose radiation effects on mammary adenocarcinoma cells – an epigenetic connection

    PubMed Central

    Luzhna, Lidia; Filkowski, Jody; Kovalchuk, Olga

    2016-01-01

    The successful treatment of cancer, including breast cancer, depends largely on radiation therapy and proper diagnostics. The effect of ionizing radiation on cells and tissues depends on the radiation dose and energy level, but there is insufficient evidence concerning how tumor cells respond to the low and high doses of radiation that are often used in medical diagnostic and treatment modalities. The purpose of this study was to investigate radiation-induced gene expression changes in the MCF-7 breast adenocarcinoma cell line. Using microarray technology tools, we were able to screen the differential gene expressions profiles between various radiation doses applied to MCF-7 cells. Here, we report the substantial alteration in the expression level of genes after high-dose treatment. In contrast, no dramatic gene expression alterations were noticed after the application of low and medium doses of radiation. In response to a high radiation dose, MCF-7 cells exhibited down-regulation of biological pathways such as cell cycle, DNA replication, and DNA repair and activation of the p53 pathway. Similar dose-dependent responses were seen on the epigenetic level, which was tested by a microRNA expression analysis. MicroRNA analysis showed dose-dependent radiation-induced microRNA expression alterations that were associated with cell cycle arrest and cell death. An increased rate of apoptosis was determined by an Annexin V assay. The results of this study showed that high doses of radiation affect gene expression genetically and epigenetically, leading to alterations in cell cycle, DNA replication, and apoptosis. PMID:27226982

  14. High and low dose radiation effects on mammary adenocarcinoma cells - an epigenetic connection.

    PubMed

    Luzhna, Lidia; Filkowski, Jody; Kovalchuk, Olga

    2016-01-01

    The successful treatment of cancer, including breast cancer, depends largely on radiation therapy and proper diagnostics. The effect of ionizing radiation on cells and tissues depends on the radiation dose and energy level, but there is insufficient evidence concerning how tumor cells respond to the low and high doses of radiation that are often used in medical diagnostic and treatment modalities. The purpose of this study was to investigate radiation-induced gene expression changes in the MCF-7 breast adenocarcinoma cell line. Using microarray technology tools, we were able to screen the differential gene expressions profiles between various radiation doses applied to MCF-7 cells. Here, we report the substantial alteration in the expression level of genes after high-dose treatment. In contrast, no dramatic gene expression alterations were noticed after the application of low and medium doses of radiation. In response to a high radiation dose, MCF-7 cells exhibited down-regulation of biological pathways such as cell cycle, DNA replication, and DNA repair and activation of the p53 pathway. Similar dose-dependent responses were seen on the epigenetic level, which was tested by a microRNA expression analysis. MicroRNA analysis showed dose-dependent radiation-induced microRNA expression alterations that were associated with cell cycle arrest and cell death. An increased rate of apoptosis was determined by an Annexin V assay. The results of this study showed that high doses of radiation affect gene expression genetically and epigenetically, leading to alterations in cell cycle, DNA replication, and apoptosis.

  15. KREAM: Korean Radiation Exposure Assessment Model for Aviation Route Dose

    NASA Astrophysics Data System (ADS)

    Hwang, J.; Dokgo, K.; Choi, E. J.; Kim, K. C.; Kim, H. P.; Cho, K. S. F.

    2014-12-01

    Since Korean Air has begun to use the polar route from Seoul/ICN airport to New York/JFK airport on August 2006, there are explosive needs for the estimation and prediction against cosmic radiation exposure for Korean aircrew and passengers in South Korea from public. To keep pace with those needs of public, Korean government made the law on safety standards and managements of cosmic radiation for the flight attendants and the pilots in 2013. And we have begun to develop our own Korean Radiation Exposure Assessment Model (KREAM) for aviation route dose since last year funded by Korea Meteorological Administration (KMA). GEANT4 model and NRLMSIS 00 model are used for calculation of the energetic particles' transport in the atmosphere and for obtaining the background atmospheric neutral densities depending on altitude. For prediction the radiation exposure in many routes depending on the various space weather effects, we constructed a database from pre-arranged simulations using all possible combinations of R, S, and G, which are the space weather effect scales provided by the National Oceanic and Atmospheric Administration (NOAA). To get the solar energetic particles' spectrum at the 100 km altitude which we set as a top of the atmospheric layers in the KREAM, we use ACE and GOES satellites' proton flux observations. We compare the results between KREAM and the other cosmic radiation estimation programs such as CARI-6M which is provided by the Federal Aviation Agency (FAA). We also validate KREAM's results by comparison with the measurement from Liulin-6K LET spectrometer onboard Korean commercial flights and Korean Air Force reconnaissance flights.

  16. Occupational radiation doses among diagnostic radiation workers in South Korea, 1996-2006.

    PubMed

    Lee, Won Jin; Cha, Eun Shil; Ha, Mina; Jin, Young-Woo; Hwang, Seung-Sik; Kong, Kyoung Ae; Lee, Seung Won; Lee, Hyun Koo; Lee, Kwang-Yong; Kim, Hyeog Ju

    2009-08-01

    This study details the distribution and trends of doses of occupational radiation among diagnostic radiation workers by using the national dose registry between 1996 and 2006 by the Korea Food and Drug Administration. Dose measurements were collected quarterly by the use of thermoluminescent dosimeter personal monitors. A total of 61 732 workers were monitored, including 18 376 radiologic technologists (30 %), 13 762 physicians (22 %), 9858 dentists (16 %) and 6114 dental hygienists (9.9 %). The average annual effective doses of all monitored workers decreased from 1.75 to 0.80 mSv over the study period. Among all diagnostic radiation workers, radiologic technologists received both the highest effective and collective doses. Male radiologic technologists aged 30-49 y composed the majority of workers receiving more than 5 mSv in a quarter. More intensive monitoring of occupational radiation exposure and investigation into its health effects on diagnostic radiation workers are required in South Korea.

  17. Low dose radiation-induced endothelial cell retraction.

    PubMed

    Kantak, S S; Diglio, C A; Onoda, J M

    1993-09-01

    We characterized in vitro the effects of gamma-radiation (12.5-100 cGy) on pulmonary microvascular endothelial cell (PMEC) morphology and F-actin organization. Cellular retraction was documented by phase-contrast microscopy and the organization of actin microfilaments was determined by immunofluorescence. Characterization included radiation dose effects, their temporal duration and reversibility of the effects. A dose-dependent relationship between the level of exposure (12.5-100 cGy) and the rate and extent of endothelial retraction was observed. Moreover, analysis of radiation-induced depolymerization of F-actin microfilament stress fibres correlated positively with the changes in PMEC morphology. The depolymerization of the stress fibre bundles was dependent on radiation dose and time. Cells recovered from exposure to reform contact inhibited monolayers > or = 24 h post-irradiation. Concomitantly, the depolymerized microfilaments reorganized to their preirradiated state as microfilament stress fibres arrayed parallel to the boundaries of adjacent contact-inhibited cells. The data presented here are representative of a series of studies designed to characterize low-dose radiation effects on pulmonary microvascular endothelium. Our data suggest that post-irradiation lung injuries (e.g. oedema) may be induced with only a single fraction of therapeutic radiation, and thus microscopic oedema may initiate prior to the lethal effects of radiation on the microvascular endothelium, and much earlier than would be suggested by the time course for clinically-detectable oedema.

  18. Linking Doses with Clinical Scores of Hematopoietic Acute Radiation Syndrome.

    PubMed

    Hu, Shaowen

    2016-10-01

    In radiation accidents, determining the radiation dose the victim received is a key step for medical decision making and patient prognosis. To reconstruct and evaluate the absorbed dose, researchers have developed many physical devices and biological techniques during the last decades. However, using the physical parameter "absorbed dose" alone is not sufficient to predict the clinical development of the various organs injured in an individual patient. In operational situations for radiation accidents, medical responders need more urgently to classify the severity of the radiation injury based on the signs and symptoms of the patient. In this work, the author uses a unified hematopoietic model to describe dose-dependent dynamics of granulocytes, lymphocytes, and platelets, and the corresponding clinical grading of hematopoietic acute radiation syndrome. This approach not only visualizes the time course of the patient's probable outcome in the form of graphs but also indirectly gives information of the remaining stem and progenitor cells, which are responsible for the autologous recovery of the hematopoietic system. Because critical information on the patient's clinical evolution can be provided within a short time after exposure and only peripheral cell counts are required for the simulation, these modeling tools will be useful to assess radiation exposure and injury in human-involved radiation accident/incident scenarios.

  19. Time-dependent radiation dose simulations during interplanetary space flights

    NASA Astrophysics Data System (ADS)

    Dobynde, Mikhail; Shprits, Yuri; Drozdov, Alexander; Hoffman, Jeffrey; Li, Ju

    2016-07-01

    Space radiation is one of the main concerns in planning long-term interplanetary human space missions. There are two main types of hazardous radiation - Solar Energetic Particles (SEP) and Galactic Cosmic Rays (GCR). Their intensities and evolution depend on the solar activity. GCR activity is most enhanced during solar minimum, while the most intense SEPs usually occur during the solar maximum. SEPs are better shielded with thick shields, while GCR dose is less behind think shields. Time and thickness dependences of the intensity of these two components encourage looking for a time window of flight, when radiation intensity and dose of SEP and GCR would be minimized. In this study we combine state-of-the-art space environment models with GEANT4 simulations to determine the optimal shielding, geometry of the spacecraft, and launch time with respect to the phase of the solar cycle. The radiation environment was described by the time-dependent GCR model, and the SEP spectra that were measured during the period from 1990 to 2010. We included gamma rays, electrons, neutrons and 27 fully ionized elements from hydrogen to nickel. We calculated the astronaut's radiation doses during interplanetary flights using the Monte-Carlo code that accounts for the primary and the secondary radiation. We also performed sensitivity simulations for the assumed spacecraft size and thickness to find an optimal shielding. In conclusion, we present the dependences of the radiation dose as a function of launch date from 1990 to 2010, for flight durations of up to 3 years.

  20. MIRD Dose Estimate Report No. 20: Radiation Absorbed-Dose Estimates for 111In- and 90Y-Ibritumomab Tiuxetan

    SciTech Connect

    Fisher, Darrell R.; Shen, Sui; Meredith, Ruby F.

    2009-04-16

    Absorbed dose calculations provide a scientific basis for evaluating the biological effects associated with administered radiopharmaceuticals. In cancer therapy, radiation dosimetry also supports treatment planning, dose-response analyses, predictions of therapy effectiveness, and completeness of patient medical records. In this study, we evaluated the organ radiation absorbed doses resulting from intravenously administered 111In- and 90Y-Ibritumomab Tiuxetan (Zevalin). Methods: Ten patients (six male, four female) with non-Hodgkin’s lymphoma, cared for at three different medical centers, were administered tracer 111In-Ibritumomab Tiuxetan and were assessed using planar scintillation camera imaging at five time points, blood clearance measurements, and CT-organ volumetrics, to determine patient-specific organ biokinetics and dosimetry. Explicit attenuation correction based on transmission scan or transmission measurements provided the fraction of 111In administered activity in seven major organs, the whole body, and remainder tissues over time through complete decay. Activity-time curves were constructed, and radiation doses were calculated using MIRD methods and implementing software (OLINDA-EXM). Results: Mean radiation absorbed doses in 10 cancer patients for 111In- and for 90-Y-Ibritumomab Tiuxetan are reported for 24 organs and the whole body. Biological uptake and retention data are given for seven major source organs, remainder tissues, and the whole body. Median absorbed dose values calculated by this method were compared to previously published dosimetry for Zevalin and the product package insert. Conclusions: Careful dosimetry techniques provide useful information on absorbed dose from administered radiopharmaceuticals in patients. The importance of patient-specific dosimetry emerges in high-dose radioimmunotherapy when the objective of treatment planning is to achieve disease cures safely by limiting radiation doses to any critical normal organ to a

  1. Investigation of radiation doses in open space using TLD detectors.

    PubMed

    Reitz, G; Facius, R; Bilski, P; Olko, P

    2002-01-01

    The low energy component of the cosmic radiation field is strongly modified by the shielding of the spacecraft and it is time and location dependent. Thermoluminescent lithium fluoride detectors have been applied to determine the radiation doses inside the ESA-Facility BIOPAN. The BIOPAN facility was mounted outside and launched on a Foton spacecraft and opened to space to allow exposure of several experiments to open space. Standard TLD-600. TLD-700 chips, two layers MTS-Ns sintered pellets with different effective thickness of the sensitive layer and MTS-N of different thickness have been exposed with different shielding thicknesses in front of them. The measured TL signal in the 0.1 mm thick detector just shielded by an aluminised Kapton foil of 25 microm thickness in front yielded a dose of 29.8 Gy (calibrated with 137Cs gamma rays) for an exposure time of 12.7 days: after 2.5 g.cm(-2) shielding the doses dropped to 3 mGy. The monitoring of radiation doses and its depth dose distribution outside the spacecraft are of great interest for radiation protection of astronauts working in open space. The knowledge of depth-dose distribution is a prerequisite to determine the organ doses an astronaut will receive during an extravehicular activity (EVA). The BIOPAN experiments are to be continued in the future.

  2. Cancer risks attributable to low doses of ionizing radiation: assessing what we really know.

    PubMed

    Brenner, David J; Doll, Richard; Goodhead, Dudley T; Hall, Eric J; Land, Charles E; Little, John B; Lubin, Jay H; Preston, Dale L; Preston, R Julian; Puskin, Jerome S; Ron, Elaine; Sachs, Rainer K; Samet, Jonathan M; Setlow, Richard B; Zaider, Marco

    2003-11-25

    High doses of ionizing radiation clearly produce deleterious consequences in humans, including, but not exclusively, cancer induction. At very low radiation doses the situation is much less clear, but the risks of low-dose radiation are of societal importance in relation to issues as varied as screening tests for cancer, the future of nuclear power, occupational radiation exposure, frequent-flyer risks, manned space exploration, and radiological terrorism. We review the difficulties involved in quantifying the risks of low-dose radiation and address two specific questions. First, what is the lowest dose of x- or gamma-radiation for which good evidence exists of increased cancer risks in humans? The epidemiological data suggest that it is approximately 10-50 mSv for an acute exposure and approximately 50-100 mSv for a protracted exposure. Second, what is the most appropriate way to extrapolate such cancer risk estimates to still lower doses? Given that it is supported by experimentally grounded, quantifiable, biophysical arguments, a linear extrapolation of cancer risks from intermediate to very low doses currently appears to be the most appropriate methodology. This linearity assumption is not necessarily the most conservative approach, and it is likely that it will result in an underestimate of some radiation-induced cancer risks and an overestimate of others.

  3. Dose-dependent hepatic transcriptional responses in Atlantic salmon (Salmo salar) exposed to sublethal doses of gamma radiation.

    PubMed

    Song, You; Salbu, Brit; Teien, Hans-Christian; Heier, Lene Sørlie; Rosseland, Bjørn Olav; Tollefsen, Knut Erik

    2014-11-01

    Due to the production of free radicals, gamma radiation may pose a hazard to living organisms. The high-dose radiation effects have been extensively studied, whereas the ecotoxicity data on low-dose gamma radiation is still limited. The present study was therefore performed using Atlantic salmon (Salmo salar) to characterize effects of low-dose (15, 70 and 280 mGy) gamma radiation after short-term (48h) exposure. Global transcriptional changes were studied using a combination of high-density oligonucleotide microarrays and quantitative real-time reverse transcription polymerase chain reaction (qPCR). Differentially expressed genes (DEGs; in this article the phrase gene expression is taken as a synonym of gene transcription, although it is acknowledged that gene expression can also be regulated, e.g., at protein stability and translational level) were determined and linked to their biological meanings predicted using both Gene Ontology (GO) and mammalian ortholog-based functional analyses. The plasma glucose level was also measured as a general stress biomarker at the organism level. Results from the microarray analysis revealed a dose-dependent pattern of global transcriptional responses, with 222, 495 and 909 DEGs regulated by 15, 70 and 280 mGy gamma radiation, respectively. Among these DEGs, only 34 were commonly regulated by all radiation doses, whereas the majority of differences were dose-specific. No GO functions were identified at low or medium doses, but repression of DEGs associated with GO functions such as DNA replication, cell cycle regulation and response to reactive oxygen species (ROS) were observed after 280mGy gamma exposure. Ortholog-based toxicity pathway analysis further showed that 15mGy radiation affected DEGs associated with cellular signaling and immune response; 70mGy radiation affected cell cycle regulation and DNA damage repair, cellular energy production; and 280mGy radiation affected pathways related to cell cycle regulation and DNA

  4. Radon Release and Its Simulated Effect on Radiation Doses.

    PubMed

    Orabi, Momen

    2017-03-01

    One of the main factors that affect the uncertainty in calculating the gamma-radiation absorbed dose rate inside a room is the variation in the degree of secular equilibrium of the considered radioactive series. A component of this factor, considered in this paper, is the release of radon (Rn) from building materials to the living space of the room. This release takes place through different steps. These steps are represented and mathematically formulated. The diffusion of radon inside the material is described by Fick's second law. Some of the factors affecting the radon release rate (e.g. covering walls, moisture, structure of the building materials, etc.) are discussed. This scheme is used to study the impact of radon release on the gamma-radiation absorbed dose rate inside a room. The investigation is carried out by exploiting the MCNP simulation software. Different building materials are considered with different radon release rates. Special care is given to Rn due to its relatively higher half-life and higher indoor concentration than the other radon isotopes. The results of the presented model show that the radon release is of a significant impact in some building materials.

  5. Contribution of maternal radionuclide burdens to prenatal radiation doses

    SciTech Connect

    Sikov, M.R.; Traub, R.J.; Meznarich, H.K. )

    1990-10-01

    This report describes approaches to calculating and expressing radiation doses to the embryo/fetus from internal radionuclides. Information was obtained for selected, occupationally significant radioelements to provide a spectrum of metabolic and dosimetric characteristics. Fractional placental transfer and ratios of concentration in the embryo/fetus to that in the woman were calculated for these materials, and were integrated with data from biokinetic transfer models to estimate radioactivity levels in the embryo/fetus as a function of stage of pregnancy and time after entry. The MIRD methodologies were extended to formalize and describe details for calculating radiation adsorbed doses to the embryo/fetus. Calculations were performed for representative situations; introduction of 1 {mu}Ci into a woman's blood at successive months of pregnancy was assumed to accommodate the stage dependence of geometric relationships and biological behaviors. Summary tables of results, correlations, and dosimetric relations, and of tentative generalized categorizations are provided in the report. 60 refs., 3 figs., 3 tabs.

  6. Radiation dose reduction in time-resolved CT angiography using highly constrained back projection reconstruction

    PubMed Central

    Supanich, Mark; Tao, Yinghua; Nett, Brian; Pulfer, Kari; Hsieh, Jiang; Turski, Patrick; Mistretta, Charles; Rowley, Howard; Chen, Guang-Hong

    2010-01-01

    Recently dynamic, time-resolved three-dimensional computed tomography angiography (CTA) has been introduced to the neurological imaging community. However, the radiation dose delivered to patients in time-resolved CTA protocol is a high and potential risk associated with the ionizing radiation dose. Thus, minimizing the radiation dose is highly desirable for time-resolved CTA. In order to reduce the radiation dose delivered during dynamic, contrast-enhanced CT applications, we introduce here the CT formulation of HighlY constrained back PRojection (HYPR) imaging. We explore the radiation dose reduction approaches of both acquiring a reduced number of projections for each image and lowering the tube current used during acquisition. We then apply HYPR image reconstruction to produce image sets at a reduced patient dose and with low image noise. Numerical phantom experiments and retrospective analysis of in vivo canine studies are used to assess the accuracy and quality of HYPR reduced dose image sets and validate our approach. Experimental results demonstrated that a factor of 6–8 times radiation dose reduction is possible when the HYPR algorithm is applied to time-resolved CTA exams. PMID:19567941

  7. Errors and Uncertainties in Dose Reconstruction for Radiation Effects Research

    SciTech Connect

    Strom, Daniel J.

    2008-04-14

    Dose reconstruction for studies of the health effects of ionizing radiation have been carried out for many decades. Major studies have included Japanese bomb survivors, atomic veterans, downwinders of the Nevada Test Site and Hanford, underground uranium miners, and populations of nuclear workers. For such studies to be credible, significant effort must be put into applying the best science to reconstructing unbiased absorbed doses to tissues and organs as a function of time. In many cases, more and more sophisticated dose reconstruction methods have been developed as studies progressed. For the example of the Japanese bomb survivors, the dose surrogate “distance from the hypocenter” was replaced by slant range, and then by TD65 doses, DS86 doses, and more recently DS02 doses. Over the years, it has become increasingly clear that an equal level of effort must be expended on the quantitative assessment of uncertainty in such doses, and to reducing and managing uncertainty. In this context, this paper reviews difficulties in terminology, explores the nature of Berkson and classical uncertainties in dose reconstruction through examples, and proposes a path forward for Joint Coordinating Committee for Radiation Effects Research (JCCRER) Project 2.4 that requires a reasonably small level of effort for DOSES-2008.

  8. Total ionizing dose radiation effects on NMOS parasitic transistors in advanced bulk CMOS technology devices

    NASA Astrophysics Data System (ADS)

    Baoping, He; Zujun, Wang; Jiangkun, Sheng; Shaoyan, Huang

    2016-12-01

    In this paper, total ionizing dose effect of NMOS transistors in advanced CMOS technology are examined. The radiation tests are performed at 60Co sources at the dose rate of 50 rad (Si)/s. The investigation's results show that the radiation-induced charge buildup in the gate oxide can be ignored, and the field oxide isolation structure is the main total dose problem. The total ionizing dose (TID) radiation effects of field oxide parasitic transistors are studied in detail. An analytical model of radiation defect charge induced by TID damage in field oxide is established. The I - V characteristics of the NMOS parasitic transistors at different doses are modeled by using a surface potential method. The modeling method is verified by the experimental I - V characteristics of 180 nm commercial NMOS device induced by TID radiation at different doses. The model results are in good agreement with the radiation experimental results, which shows the analytical model can accurately predict the radiation response characteristics of advanced bulk CMOS technology device. Project supported by the National Natural Science Foundation of China (No. 11305126).

  9. Radiation dose assessment of exposure to depleted uranium.

    PubMed

    Li, Wei Bo; Gerstmann, Udo C; Höllriegl, Vera; Szymczak, Wilfried; Roth, Paul; Hoeschen, Christoph; Oeh, Uwe

    2009-07-01

    Depleted uranium (DU) is claimed to contribute to human health problems, known as the Gulf War Syndrome and the Balkan Syndrome. Quantitative radiation dose is required to estimate the health risk of DU materials. The influences of the solubility parameters in the human alimentary tract and the respiratory tract systems and the aerosol particles size on the radiation dose of DU materials were evaluated. The dose conversion factor of daily urinary excretion of DU is provided. The retention and excretion of DU in the human body after a contamination at a wound site were predicted. Dose coefficients of DU after ingestion and inhalation were calculated using the solubility parameters of the DU corrosion products in simulated gastric and simulated lung fluid, which were determined in the Helmholtz Zentrum München. (238)U is the main radiation dose contributor per 1 Bq of DU materials. The dose coefficients of DU materials were estimated to be 3.5 x 10(-8) and 2.1 x 10(-6) Sv Bq(-1) after ingestion and inhalation for members of the public. The ingestion dose coefficient of DU materials is about 75% of the natural uranium value. The inhalation dose coefficient of DU material is in between those for Type M and Type S according to the category for inhaled materials defined by the International Commission on Radiological Protection. Radiation dose possibly received from DU materials can directly be estimated by using the dose conversion factor provided in this study, if daily urinary excretion of DU is measured.

  10. Radiation dose to the walls of hollow organs

    SciTech Connect

    Stabin, M.G.; Stubbs, J.B.

    1994-05-01

    The radiation doses to the walls of hollow organs, from activity in their contents, have traditionally been estimated as the sum of the photon dose to the wall and the maximum electron/beta dose. The photon dose is usually estimated by Monte Carlo methods, and the nonpenetrating dose estimated as the surface dose, equal to one half of the average dose to the volume. Some clinical experience, such as lack of radiotoxicity in patients estimated to have received more than 10 Gy to the walls of organs in the GI tract, led us to investigate the appropriateness of this approach. While the photon dose is thought to be fairly uniform throughout the walls of hollow organs, the electron and beta doses drop off rapidly from a maximum at the surface of the organ`s contents to zero at distances dependent on emission energy. The degree to which the activity is separated from the target cells in the wall, the uniformity of activity distribution within the contents, and the location of the cells at risk for tissue injury and carcinogenesis are some of the issues which determine the appropriate dose(s) to report. For example, in the stomach, the wall thickness varies from 0.6-1.3 cm. The epithelial surface mucus cells are 20-40 micrometers in height, and are located beneath a mucus layer which varies typically between about 0.18 and 0.6 mm in thickness This layer is thus thick enough to attenuate almost all of the electron energy emitted from Tc-99m and I-123 and 26-50% of the beta energy of Y-90. The maximum dose to the surface mucus cells, or a volume averaged dose to these and other cells, may be a better predictor of radiation effects than the maximum dose at the surface of the contents.

  11. Radiation dose detection by imaging response in biological targets.

    PubMed

    Jakob, B; Durante, M

    2012-04-01

    Imaging was one of the earliest techniques to quantify radiation dose. While films and active fluorescent detectors are still commonly used in physical dosimetry, biological imaging is emerging as a new method to visualize and quantify radiation dose in biological targets. Methods for biological imaging are normally based on molecular fluorescent probes, labeling chromatin-conjugated molecules or specific repair proteins. Examples are chromatin-binding coumarin compounds, which become fluorescent under irradiation, or the H2AX histone, which is rapidly phosphorylated at sites of DNA double-strand breaks and can be visualized by immunostaining. Many other DNA repair proteins can be expressed with fluorescent targets, such as green fluorescent protein, thus becoming visible for dose estimation in vivo. The possibility to visualize radiation damage in living biological targets is particularly important for repair kinetic studies, for estimating individual radiation response, and for remote control of living samples exposed to radiation, for instance in robotic space missions. In vivo dose monitoring in particle therapy exploits the production of positron emitters by nuclear interaction of the incident beam in the patient's body. Positron emission tomography (PET) can then be used to visualize and quantify the particle dose in the patient, and it can in principle also be used for radiotherapy with high-energy X rays. Alternatively, prompt γ rays or scattered secondary particles are under study for in vivo dosimetry of ion beams in therapy.

  12. Head and Neck Radiation Dose and Radiation Safety for Interventional Physicians.

    PubMed

    Fetterly, Kenneth; Schueler, Beth; Grams, Michael; Sturchio, Glenn; Bell, Malcolm; Gulati, Rajiv

    2017-03-13

    The first aim of this study was to assess the magnitude of radiation dose to tissues of the head and neck of physicians performing x-ray-guided interventional procedures. The second aim was to assess protection of tissues of the head offered by select wearable radiation safety devices. Radiation dose to tissues of the head and neck is of significant interest to practicing interventional physicians. However, methods to estimate radiation dose are not generally available, and furthermore, some of the available research relating to protection of these tissues is misleading. Using a single representative geometry, scatter radiation dose to a humanoid phantom was measured using radiochromic film and normalized by the radiation dose to the left collar of the radioprotective thorax apron. Radiation protection offered by leaded glasses and by a radioabsorbent surgical cap was measured. In the test geometry, average radiation doses to the unprotected brain, carotid arteries, and ocular lenses were 8.4%, 17%, and 50% of the dose measured at the left collar, respectively. Two representative types of leaded glasses reduced dose to the ocular lens on the side of the physician from which the scatter originates by 27% to 62% but offered no protection to the contralateral eye. The radioabsorbent surgical cap reduced brain dose by only 3.3%. A method by which interventional physicians can estimate dose to head and neck tissues on the basis of their personal dosimeter readings is described. Radiation protection of the ocular lenses by leaded glasses may be incomplete, and protection of the brain by a radioabsorbent surgical cap was minimal. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  13. Measurement of radiation dose in cerebral CT perfusion study.

    PubMed

    Hirata, Masaaki; Sugawara, Yoshifumi; Fukutomi, Yukimi; Oomoto, Kenji; Murase, Kenya; Miki, Hitoshi; Mochizuki, Teruhito

    2005-03-01

    To evaluate radiation dose in cerebral perfusion studies with a multi-detector row CT (MDCT) scanner on various voltage and current settings by using a human head phantom. Following the CT perfusion study protocol, continuous cine scans (1 sec/rotation x60 sec) consisting of four 5-mm-thick contiguous slices were performed three times at variable tube voltages of 80 kV, 100 kV, 120 kV, and 140 kV with the same tube current setting of 200 mA and on variable current settings of 50 mA, 100 mA, 150 mA, and 200 mA with the same tube voltage of 80 kV. Radiation doses were measured using a total of 41 theroluminescent dosimeters (TLDs) placed in the human head phantom. Thirty-six TLDs were inside and three were on the surface of the slice of the X-ray beam center, and two were placed on the surface 3 cm caudal assuming the lens position. Average radiation doses of surface, inside, and lens increased in proportion to the increases of tube voltage and tube current. The lowest inside dose was 87.6+/-15.3 mGy, and the lowest surface dose was 162.5+/-6.7 mGy at settings of 80 kV and 50 mA. The highest inside dose was 1,591.5+/-179.7 mGy, and the highest surface dose was 2,264.6+/-123.7 mGy at 140 kV-200 mA. At 80 kV-50 mA, the average radiation dose of lens was the lowest at 5.5+/-0.0 mGy. At 140 kV-200 mA the radiation dose of lens was the highest at 127.2+/-0.6 mGy. In cerebral CT perfusion study, radiation dose can vary considerably. Awareness of the patient's radiation dose is recommended.

  14. Photon: the minimum dose of electromagnetic radiation

    NASA Astrophysics Data System (ADS)

    Suntola, Tuomo

    2005-08-01

    A radio engineer can hardly think about smaller amount of electromagnetic radiation than given by a single oscillation cycle of a unit charge in a dipole. When solved from Maxwell's equations for a dipole of one wavelength, the energy of the emitted radiation cycle obtains the form Eλ = 2/3 hf, where the Planck constant h can be expressed in terms of the unit charge, e, the vacuum permeability, μ0, the velocity of light, c, and a numerical factor as h = 1.1049*2π3e2μ0c=6.62607*10-34 [kgm2/s]. A point emitter like an atom can be regarded as a dipole in the fourth dimension. The length of such dipole is measured in the direction of the line element cdt, which in one oscillation cycle means the length of one wavelength. For a dipole in the fourth dimension, three space directions are in the normal plane which eliminates the factor 2/3 from the energy expression thus leading to Planck's equation Eλ = hf for the radiation emitted by a single electron transition in an atom. The expression of the Planck constant obtained from Maxwell's equations leads to a purely numerical expression of the fine structure constant α=1/(1.1049*4π3) = 1/137 and shows that the Planck constant is directly proportional to the velocity of light. When applied to Balmer's formula, the linkage of the Planck constant to the velocity of light shows, that the frequency of an atomic oscillator is directly proportional to the velocity of light. This implies that the velocity of light is observed as constant in local measurements. Such an interpretation makes it possible to convert relativistic spacetime with variable time coordinates into space with variable clock frequencies in universal time, and thus include relativistic phenomena in the framework of quantum mechanics.

  15. Radiation Dose Testing on Juno High Voltage Cables

    NASA Technical Reports Server (NTRS)

    Green, Nelson W.; Kirkham, Harold; Kim, Wousik; McAlpine, Bill

    2008-01-01

    The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10-6 torr and cooled to -50 C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.

  16. Radiation Dose Testing on Juno High Voltage Cables

    NASA Technical Reports Server (NTRS)

    Green, Nelson W.; Kirkham, Harold; Kim, Wousik; McAlpine, Bill

    2008-01-01

    The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10(exp -6) torr and cooled to -50(deg)C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.

  17. Differential Response and Priming Dose Effect on the Proteome of Human Fibroblast and Stem Cells Induced by Exposure to Low Doses of Ionizing Radiation.

    PubMed

    Hauptmann, Monika; Haghdoost, Siamak; Gomolka, Maria; Sarioglu, Hakan; Ueffing, Marius; Dietz, Anne; Kulka, Ulrike; Unger, Kristian; Babini, Gabriele; Harms-Ringdahl, Mats; Ottolenghi, Andrea; Hornhardt, Sabine

    2016-03-01

    It has been suggested that a mechanistic understanding of the cellular responses to low dose and dose rate may be valuable in reducing some of the uncertainties involved in current risk estimates for cancer- and non-cancer-related radiation effects that are inherited in the linear no-threshold hypothesis. In this study, the effects of low-dose radiation on the proteome in both human fibroblasts and stem cells were investigated. Particular emphasis was placed on examining: 1. the dose-response relationships for the differential expression of proteins in the low-dose range (40-140 mGy) of low-linear energy transfer (LET) radiation; and 2. the effect on differential expression of proteins of a priming dose given prior to a challenge dose (adaptive response effects). These studies were performed on cultured human fibroblasts (VH10) and human adipose-derived stem cells (ADSC). The results from the VH10 cell experiments demonstrated that low-doses of low-LET radiation induced unique patterns of differentially expressed proteins for each dose investigated. In addition, a low priming radiation dose significantly changed the protein expression induced by the subsequent challenge exposure. In the ADSC the number of differentially expressed proteins was markedly less compared to VH10 cells, indicating that ADSC differ in their intrinsic response to low doses of radiation. The proteomic results are further discussed in terms of possible pathways influenced by low-dose irradiation.

  18. Multiple Testing, Cumulative Radiation Dose, and Clinical Indications in Patients Undergoing Myocardial Perfusion Imaging

    PubMed Central

    Einstein, Andrew J.; Weiner, Shepard D.; Bernheim, Adam; Kulon, Michal; Bokhari, Sabahat; Johnson, Lynne L.; Moses, Jeffrey W.; Balter, Stephen

    2013-01-01

    Context Myocardial perfusion imaging (MPI) is the single medical test with the highest radiation burden to the US population. While many patients undergoing MPI receive repeat MPI testing, or additional procedures involving ionizing radiation, no data are available characterizing their total longitudinal radiation burden and relating radiation burden with reasons for testing. Objective To characterize procedure counts, cumulative estimated effective doses of radiation, and clinical indications, for patients undergoing MPI. Design, Setting, Patients Retrospective cohort study evaluating, for 1097 consecutive patients undergoing index MPI during the first 100 days of 2006 at Columbia University Medical Center, all preceding medical imaging procedures involving ionizing radiation undergone beginning October 1988, and all subsequent procedures through June 2008, at that center. Main Outcome Measures Cumulative estimated effective dose of radiation, number of procedures involving radiation, and indications for testing. Results Patients underwent a median (interquartile range, mean) of 15 (6–32, 23.9) procedures involving radiation exposure; 4 (2–8, 6.5) were high-dose (≥3 mSv, i.e. one year's background radiation), including 1 (1–2, 1.8) MPI studies per patient. 31% of patients received cumulative estimated effective dose from all medical sources >100mSv. Multiple MPIs were performed in 39% of patients, for whom cumulative estimated effective dose was 121 (81–189, 149) mSv. Men and whites had higher cumulative estimated effective doses, and there was a trend towards men being more likely to undergo multiple MPIs than women (40.8% vs. 36.6%, Odds ratio 1.29, 95% confidence interval 0.98–1.69). Over 80% of initial and 90% of repeat MPI exams were performed in patients with known cardiac disease or symptoms consistent with it. Conclusion In this institution, multiple testing with MPI was very common, and in many patients associated with very high cumulative

  19. Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

    SciTech Connect

    Ebert, Martin A.; Foo, Kerwyn; Haworth, Annette; Gulliford, Sarah L.; Kennedy, Angel; Joseph, David J.; Denham, James W.

    2015-03-01

    Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with a comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for

  20. Analysis of Radiation Impact on White Mice through Radiation Dose Mapping in Medical Physics Laboratory

    NASA Astrophysics Data System (ADS)

    Sutikno, Madnasri; Susilo; Arya Wijayanti, Riza

    2016-08-01

    A study about X-ray radiation impact on the white mice through radiation dose mapping in Medical Physic Laboratory is already done. The purpose of this research is to determine the minimum distance of radiologist to X-ray instrument through treatment on the white mice. The radiation exposure doses are measured on the some points in the distance from radiation source between 30 cm up to 80 with interval of 30 cm. The impact of radiation exposure on the white mice and the effects of radiation measurement in different directions are investigated. It is founded that minimum distance of radiation worker to radiation source is 180 cm and X-ray has decreased leukocyte number and haemoglobin and has increased thrombocyte number in the blood of white mice.

  1. SYNCHROTRON RADIATION, FREE ELECTRON LASER, APPLICATION OF NUCLEAR TECHNOLOGY, ETC.: Measurement of radiation dose at the north interaction point of BEPC II

    NASA Astrophysics Data System (ADS)

    Mo, Xiao-Hu; Zhang, Jian-Yong; Zhang, Tian-Bao; Zhang, Qing-Jiang; Achasov, Mikhail; Fu, Cheng-Dong; Muchnoi, Nikolay; Qin, Qing; Qu, Hua-Min; Wang, Yi-Fang; Wu, Jing-Min; Xu, Jin-Qiang; Yu, Bo-Xiang

    2009-10-01

    The technique details for measuring radiation dose are expounded. The results of gamma and neutron radiation levels are presented and the corresponding radiation shielding is discussed based on the simplified estimation. In addition, the photon radiation level move as background for future experiments is measured by a NaI(Tl) detector.

  2. [Comparison of chest and abdominal x-ray radiation dose and its image quality-a multi-center study].

    PubMed

    Uto, Tomoyuki; Ishiyama, Akihiro; Kimura, Hiroya; Katuragi, Yuji; Masunari, Toyokazu; Shibutani, Takayuki; Ishiki, Koichi; Nakanishi, Ken; Anai, Tatuya; Sumida, Shigeru; Morimatu, Takashi; Miyano, Hideto

    2011-01-01

    While radiography provides us clinically valuable information, it increases the risk of radiation exposure. Previous studies have reported great variations in radiation doses among institutions. It is concerning that radiation doses will increase and vary greatly from institution to institution when digital radiographic modalities become more common. In the present study, we measured chest and abdominal radiation doses at 10 institutions that had X-ray digital imaging systems. Differences in radiation doses among the institutions were evaluated and compared with the previous reports. The image quality at the measured radiation doses were also evaluated. The doses were measured by the same dosimeter, and the image quality at a specific dose was evaluated using the standard deviation of the digital values and Wiener spectrum. Our results indicate that the difference in radiation among institutions was approximately five-fold at a maximum and smaller than the previous reports had indicated. The image quality was improved as the dose was increased. We considered the five-fold difference to be the result of variations in optimum image quality and associated radiation doses among institutions. In summary, evaluating the radiation dose along with the image quality is important to optimize the doses.

  3. Equivalent dose and effective dose from stray radiation during passively scattered proton radiotherapy for prostate cancer

    NASA Astrophysics Data System (ADS)

    Fontenot, Jonas; Taddei, Phillip; Zheng, Yuanshui; Mirkovic, Dragan; Jordan, Thomas; Newhauser, Wayne

    2008-03-01

    Proton therapy reduces the integral therapeutic dose required for local control in prostate patients compared to intensity-modulated radiotherapy. One proposed benefit of this reduction is an associated decrease in the incidence of radiogenic secondary cancers. However, patients are also exposed to stray radiation during the course of treatment. The purpose of this study was to quantify the stray radiation dose received by patients during proton therapy for prostate cancer. Using a Monte Carlo model of a proton therapy nozzle and a computerized anthropomorphic phantom, we determined that the effective dose from stray radiation per therapeutic dose (E/D) for a typical prostate patient was approximately 5.5 mSv Gy-1. Sensitivity analysis revealed that E/D varied by ±30% over the interval of treatment parameter values used for proton therapy of the prostate. Equivalent doses per therapeutic dose (HT/D) in specific organs at risk were found to decrease with distance from the isocenter, with a maximum of 12 mSv Gy-1 in the organ closest to the treatment volume (bladder) and 1.9 mSv Gy-1 in the furthest (esophagus). Neutrons created in the nozzle predominated effective dose, though neutrons created in the patient contributed substantially to the equivalent dose in organs near the proton field. Photons contributed less than 15% to equivalent doses.

  4. Metaphase chromosome aberrations as markers of radiation exposure and dose

    SciTech Connect

    Brooks, A.L.; Khan, M.A.; Jostes, R.F.; Cross, F.T.

    1992-10-01

    Chromosome aberration frequency provides the most reliable biological marker of dose for detecting acute accidental radiation exposure. Significant radiation-induced changes in the frequency of chromosome aberrations can be detected at very low doses. Our paper provides information on using molecular chromosome probes paints'' to score chromosome damage and illustrates how technical advances make it possible to understand mechanisms involved during formation of chromosome aberrations. In animal studies chromosome aberrations provide a method to relate cellular damage to cellular dose. Using an In vivo/In vitro approach aberrations provided a biological marker of dose from radon progeny exposure which was used to convert WLM to dose in rat tracheal epithelial cells. Injection of Chinese hamsters with [sup 144]Ce which produced a low dose rate exposure of bone marrow to either low-LET radiation increased the sensitivity of the cells to subsequent external exposure to [sup 60]Co. These studies demonstrated the usefulness of chromosome damage as a biological marker of dose and cellular responsiveness.

  5. Metaphase chromosome aberrations as markers of radiation exposure and dose

    SciTech Connect

    Brooks, A.L.; Khan, M.A.; Jostes, R.F.; Cross, F.T.

    1992-10-01

    Chromosome aberration frequency provides the most reliable biological marker of dose for detecting acute accidental radiation exposure. Significant radiation-induced changes in the frequency of chromosome aberrations can be detected at very low doses. Our paper provides information on using molecular chromosome probes ``paints`` to score chromosome damage and illustrates how technical advances make it possible to understand mechanisms involved during formation of chromosome aberrations. In animal studies chromosome aberrations provide a method to relate cellular damage to cellular dose. Using an In vivo/In vitro approach aberrations provided a biological marker of dose from radon progeny exposure which was used to convert WLM to dose in rat tracheal epithelial cells. Injection of Chinese hamsters with {sup 144}Ce which produced a low dose rate exposure of bone marrow to either low-LET radiation increased the sensitivity of the cells to subsequent external exposure to {sup 60}Co. These studies demonstrated the usefulness of chromosome damage as a biological marker of dose and cellular responsiveness.

  6. Estimation of organ dose equivalents from residents of radiation-contaminated buildings with Rando phantom measurements.

    PubMed

    Lee, J S; Dong, S L; Wu, T H

    1999-05-01

    Since August 1996, a dose reconstruction model has been conducted with thermoluminescent dosimeter (TLD)-embedded chains, belts and badges for external dose measurements on the residents in radiation-contaminated buildings. The TLD dosimeters, worn on the front of the torso, would not be adequate for dose measurement in cases when the radiation is anisotropic or the incident angles of radiation sources are not directed in the front-to-back direction. The shielding and attenuation by the body would result in the dose equivalent estimation being somewhat skewed. An organ dose estimation method with a Rando phantom under various exposure geometries is proposed. The conversion factors, obtained from the phantom study, may be applicable to organ dose estimations for residents in the contaminated buildings if the incident angles correspond to the phantom simulation results. There is a great demand for developing a mathematical model or Monte Carlo calculation to deal with complicated indoor layout geometry problems involving ionizing radiation. Further research should be directed toward conducting laboratory simulation by investigating the relationship between doses delivered from multiple radiation sources. It is also necessary to collaborate with experimental biological dosimetry, such as chromosome aberration analysis, fluorescence in situ hybridization (FISH) and retrospective ESR-dosimetry with teeth, applied to the residents, so that the organ dose equivalent estimations may be more reliable for radio-epidemiological studies.

  7. Evaluation of radiation dose to anthropomorphic paediatric models from positron-emitting labelled tracers

    NASA Astrophysics Data System (ADS)

    Xie, Tianwu; Zaidi, Habib

    2014-03-01

    PET uses specific molecules labelled with positron-emitting radionuclides to provide valuable biochemical and physiological information. However, the administration of radiotracers to patients exposes them to low-dose ionizing radiation, which is a concern in the paediatric population since children are at a higher cancer risk from radiation exposure than adults. Therefore, radiation dosimety calculations for commonly used positron-emitting radiotracers in the paediatric population are highly desired. We evaluate the absorbed dose and effective dose for 19 positron-emitting labelled radiotracers in anthropomorphic paediatric models including the newborn, 1-, 5-, 10- and 15-year-old male and female. This is achieved using pre-calculated S-values of positron-emitting radionuclides of UF-NCI paediatric phantoms and published biokinetic data for various radiotracers. The influence of the type of anthropomorphic model, tissue weight factors and direct human- versus mouse-derived biokinetic data on the effective dose for paediatric phantoms was also evaluated. In the case of 18F-FDG, dosimetry calculations of reference paediatric patients from various dose regimens were also calculated. Among the considered radiotracers, 18F-FBPA and 15O-water resulted in the highest and lowest effective dose in the paediatric phantoms, respectively. The ICRP 103 updated tissue-weighting factors decrease the effective dose in most cases. Substantial differences of radiation dose were observed between direct human- versus mouse-derived biokinetic data. Moreover, the effect of using voxel- versus MIRD-type models on the calculation of the effective dose was also studied. The generated database of absorbed organ dose and effective dose for various positron-emitting labelled radiotracers using new generation computational models and the new ICRP tissue-weighting factors can be used for the assessment of radiation risks to paediatric patients in clinical practice. This work also contributes

  8. Radiation dose to personnel during percutaneous renal calculus removal

    SciTech Connect

    Bush, W.H.; Jones, D.; Brannen, G.E.

    1985-12-01

    Radiation dose to the radiologist and other personnel was measured during 102 procedures for percutaneous removal of renal calculi from the upper collecting system. A mobile C-arm image intensifier was used to guide entrance to the kidney and stone removal. Average fluoroscopy time was 25 min. Exposure to personnel was monitored by quartz-fiber dosimeters at the collar level above the lead apron. Average radiation dose to the radiologist was 10 mrem (0.10 mSv) per case; to the surgical nurse, 4 mrem (0.04 mSv) per case; to the radiologic technologist, 4 mrem (0.04 mSv) per case; and to the anesthesiologist, 3 mrem (0.03 mSv) per case. Radiation dose to the uroradiologic team during percutaneous nephrostolithotomy is similar to that from other interventional fluoroscopic procedures and is within acceptable limits for both physicians and assisting personnel.

  9. Radiation dose and radiation protection principle awareness: a survey among Nigerian paediatricians.

    PubMed

    Famurewa, O C; Obiajunwa, P O; Elusiyan, J B; Ibitoye, B O

    2014-03-01

    This study is aimed at determining the knowledge of Paediatricians in Nigeria about the basic principle of radiation protection ALARA (As Low As Reasonably Achievable) and their knowledge of the radiation doses that children receive during some common radiological procedures. Two hundred and fifty questionnaires were circulated among paediatricians at the 2012 annual Paediatricians' Association of Nigeria Conference. The questionnaires contain 10 questions designed to asses the pediatricians' general knowledge on : ionising radiation and the risks, doses children receive during some common radiological procedures and awareness of the radiation protection principle, ALARA ( As Low As Reasonably Achievable). Of the 162 Paediatricians that participated, 69% named at least one non medical source of ionising radiation, 54.9% would not recommend CXR to screen an apparently healthy child for tuberculosis and 87% believe that children are at greater risk of adverse effects of ionising radiation. For dose estimation, 51.9% and 51.2% of the paediatricians underestimated doses received during Cranial and abdominal computerised tomography respectively while 13.6% and 37% respectively erroneously believed that abdominal ultrasound and brain magnetic resonance imaging utilise ionising radiation. 13.6% gave the correct meaning of the Acronym ALARA. The Paediatricians' knowledge about the basic principle of radiation protection ALARA and the doses that children receive during some common radiological procedures is poor. There is need to ensure adequate training on radiation hazards and protection at all levels of medical education.

  10. Measurements of individual radiation doses in residents living around the Fukushima Nuclear Power Plant.

    PubMed

    Nagataki, Shigenobu; Takamura, Noboru; Kamiya, Kenji; Akashi, Makoto

    2013-11-01

    effects. In particular, the schedule of decontamination needs reconsideration. The decontamination map is determined based on the results of airborne monitoring and the radiation dose calculated from readings taken at the monitoring posts at the initial period of the accident. The decontamination protocol should be reevaluated based on the individual doses of the people who desire to live in those areas.

  11. Study of UV radiation dose received by the Spanish population.

    PubMed

    Gurrea, Gonzalo; Cañada, Javier

    2007-01-01

    Excess exposure to UV radiation can affect our health by causing sunburn, skin cancer, etc. It is therefore useful to determine the UV dosage received by people as a way of protecting them from the possible negative effects that this kind of radiation can cause. In this work, the personal outdoor percentage, which shows the time spent in outdoor activities, as well as personal UV doses, has been calculated by means of global UV radiation on a horizontal plane. A database of average daily UVB radiation on the horizontal plane given by the National Institute of Meteorology has been used. In this work we evaluate the standard erythema dose of the Spanish population throughout the year.

  12. Radiation dose in 320-slice multidetector cardiac CT: a single center experience of evolving dose minimization.

    PubMed

    Tung, Matthew K; Cameron, James D; Casan, Joshua M; Crossett, Marcus; Troupis, John M; Meredith, Ian T; Seneviratne, Sujith K

    2013-01-01

    Minimization of radiation exposure remains an important subject that occurs in parallel with advances in scanner technology. We report our experience of evolving radiation dose and its determinants after the introduction of 320-multidetector row cardiac CT within a single tertiary cardiology referral service. Four cohorts of consecutive patients (total 525 scans), who underwent cardiac CT at defined time points as early as 2008, are described. These include a cohort just after scanner installation, after 2 upgrades of the operating system, and after introduction of an adaptive iterative image reconstruction algorithm. The proportions of nondiagnostic coronary artery segments and studies with nondiagnostic segments were compared between cohorts. Significant reductions were observed in median radiation doses in all cohorts compared with the initial cohort (P < .001). Median dose-length product fell from 944 mGy · cm (interquartile range [IQR], 567.3-1426.5 mGy · cm) to 156 mGy · cm (IQR, 99.2-265.0 mGy · cm). Although the proportion of prospectively triggered scans has increased, reductions in radiation dose have occurred independently of distribution of scan formats. In multiple regression that combined all groups, determinants of dose-length product were tube output, the number of cardiac cycles scanned, tube voltage, scan length, scan format, body mass index, phase width, and heart rate (adjusted R(2) = 0.85, P < .001). The proportion of nondiagnostic coronary artery segments was slightly increased in group 4 (2.9%; P < .01). While maintaining diagnostic quality in 320-multidetector row cardiac CT, the radiation dose has decreased substantially because of a combination of dose-reduction protocols and technical improvements. Continued minimization of radiation dose will increase the potential for cardiac CT to expand as a cardiac imaging modality. Copyright © 2013 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  13. Radiation dose from medical imaging: a primer for emergency physicians.

    PubMed

    Jones, Jesse G A; Mills, Christopher N; Mogensen, Monique A; Lee, Christoph I

    2012-05-01

    Medical imaging now accounts for most of the US population's exposure to ionizing radiation. A substantial proportion of this medical imaging is ordered in the emergency setting. We aim to provide a general overview of radiation dose from medical imaging with a focus on computed tomography, as well as a literature review of recent efforts to decrease unnecessary radiation exposure to patients in the emergency department setting. We conducted a literature review through calendar year 2010 for all published articles pertaining to the emergency department and radiation exposure. The benefits of imaging usually outweigh the risks of eventual radiation-induced cancer in most clinical scenarios encountered by emergency physicians. However, our literature review identified 3 specific clinical situations in the general adult population in which the lifetime risks of cancer may outweigh the benefits to the patient: rule out pulmonary embolism, flank pain, and recurrent abdominal pain in inflammatory bowel disease. For these specific clinical scenarios, a physician-patient discussion about such risks and benefits may be warranted. Emergency physicians, now at the front line of patients' exposure to ionizing radiation, should have a general understanding of the magnitude of radiation dose from advanced medical imaging procedures and their associated risks. Future areas of research should include the development of protocols and guidelines that limit unnecessary patient radiation exposure.

  14. Radiation dose reduction in parasinus CT by spectral shaping.

    PubMed

    May, Matthias S; Brand, Michael; Lell, Michael M; Sedlmair, Martin; Allmendinger, Thomas; Uder, Michael; Wuest, Wolfgang

    2017-02-01

    Spectral shaping aims to narrow the X-ray spectrum of clinical CT. The aim of this study was to determine the image quality and the extent of radiation dose reduction that can be achieved by tin prefiltration for parasinus CT. All scans were performed with a third generation dual-source CT scanner. A study protocol was designed using 100 kV tube voltage with tin prefiltration (200 mAs) that provides image noise levels comparable to a low-dose reference protocol using 100 kV without spectral shaping (25 mAs). One hundred consecutive patients were prospectively enrolled and randomly assigned to the study or control group. All patients signed written informed consent. The study protocol was approved by the local Institutional Review Board and applies to the HIPAA. Subjective and objective image quality (attenuation values, image noise, and contrast-to-noise ratio (CNR)) were assessed. Radiation exposure was assessed as volumetric CT dose index, and effective dose was estimated. Mann-Whitney U test was performed for radiation exposure and for image noise comparison. All scans were of diagnostic image quality. Image noise in air, in the retrobulbar fat, and in the eye globe was comparable between both groups (all p > 0.05). CNReye globe/air did not differ significantly between both groups (p = 0.7). Radiation exposure (1.7 vs. 2.1 mGy, p < 0.01) and effective dose (0.055 vs. 0.066 mSv, p < 0.01) were significantly reduced in the study group. Radiation dose can be further reduced by 17% for low-dose parasinus CT by tin prefiltration maintaining diagnostic image quality.

  15. Exposure of luminous marine bacteria to low-dose gamma-radiation.

    PubMed

    Kudryasheva, N S; Petrova, A S; Dementyev, D V; Bondar, A A

    2017-04-01

    The study addresses biological effects of low-dose gamma-radiation. Radioactive (137)Cs-containing particles were used as model sources of gamma-radiation. Luminous marine bacterium Photobacterium phosphoreum was used as a bioassay with the bioluminescent intensity as the physiological parameter tested. To investigate the sensitivity of the bacteria to the low-dose gamma-radiation exposure (≤250 mGy), the irradiation conditions were varied as follows: bioluminescence intensity was measured at 5, 10, and 20°С for 175, 100, and 47 h, respectively, at different dose rates (up to 4100 μGy/h). There was no noticeable effect of gamma-radiation at 5 and 10°С, while the 20°С exposure revealed authentic bioluminescence inhibition. The 20°С results of gamma-radiation exposure were compared to those for low-dose alpha- and beta-radiation exposures studied previously under comparable experimental conditions. In contrast to ionizing radiation of alpha and beta types, gamma-emission did not initiate bacterial bioluminescence activation (adaptive response). As with alpha- and beta-radiation, gamma-emission did not demonstrate monotonic dose-effect dependencies; the bioluminescence inhibition efficiency was found to be related to the exposure time, while no dose rate dependence was found. The sequence analysis of 16S ribosomal RNA gene did not reveal a mutagenic effect of low-dose gamma radiation. The exposure time that caused 50% bioluminescence inhibition was suggested as a test parameter for radiotoxicity evaluation under conditions of chronic low-dose gamma irradiation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Radiation dose required for the vulcanization of natural rubber latex

    NASA Astrophysics Data System (ADS)

    Haque, M. E.; Dafader, N. C.; Akhtar, F.; Ahmad, M. U.

    1996-10-01

    The radiation dose required for the vulcanization of natural rubber latex was optimized. To enhance the crosslinking, several sensitizers were used. Among the sensitizers, n-butyl acrylate ( n-BA) alone was found to be the best one. The effects of concentration of n-Ba, mixing and standing time of latex with n-BA on the tensile properties of latex film were investigated. 12 kGy radiation dose, 5 phr n-BA and 30-40 min of mixing time were found to be the optimum conditions for irradiation.

  17. Justification of permissible doses of radiation during prolonged space flights

    NASA Technical Reports Server (NTRS)

    Grigoryev, Y. G.; Abel, K.; Varteres, V.; Nilolov, N.; Karpfel, Z.; Prislichka, M.

    1974-01-01

    Maximum permissible radiation doses for astronauts are reported based on chronic radiation experiments with dogs and actual measurements during space flights. Observed were clinical conditions, peripheral blood and marrow, the state of the cardiovascular system, higher nervous activity, the state of the vestibular analyzer, the organ of vision, spermatogenic function and the ability to reproduce, the state of immunity and a number of biological indices in blood and tissues. The following maximum permissible doses are determined as preliminary values: 1 year of flight - 200 rem; 2 years of flight - 250 rem; 3 years of flight - 275 rem.

  18. Dosimeter for measuring skin dose and more deeply penetrating radiation

    DOEpatents

    Jones, Donald E.; Parker, DeRay; Boren, Paul R.

    1981-01-01

    A personnel dosimeter includes a plurality of compartments containing thermoluminescent dosimeter phosphors for registering radiation dose absorbed in the wearer's sensitive skin layer and for registering more deeply penetrating radiation. Two of the phosphor compartments communicate with thin windows of different thicknesses to obtain a ratio of shallowly penetrating radiation, e.g. beta. A third phosphor is disposed within a compartment communicating with a window of substantially greater thickness than the windows of the first two compartments for estimating the more deeply penetrating radiation dose. By selecting certain phosphors that are insensitive to neutrons and by loading the holder material with netruon-absorbing elements, energetic neutron dose can be estimated separately from other radiation dose. This invention also involves a method of injection molding of dosimeter holders with thin windows of consistent thickness at the corresponding compartments of different holders. This is achieved through use of a die insert having the thin window of precision thickness in place prior to the injection molding step.

  19. Cell-oriented alternatives to dose, quality factor, and dose equivalent for low-level radiation

    SciTech Connect

    Sondhaus, C.A.; Bond, V.P.; Feinendegen, L.E. )

    1990-07-01

    Randomly occurring energy deposition events produced by low levels of ionizing radiation interacting with tissue deliver variable amounts of energy to sensitive target volumes within a small fraction of the tissue cell population. A model is described in which an experimentally derived function relating event size to cell response probability operates mathematically on the microdosimetric event size distribution characterizing a given irradiation and thus determines the total fractional number of responding cells; this fraction measures the effectiveness of the given radiation. Applying this cell response or hit size effectiveness function (HSEF) to different radiations and normalizing to equal numbers of responses produced by each radiation should define its radiation quality, or relative effectiveness, on a more nearly absolute basis than do the absorbed dose and dose equivalent, both of which are confounded when applied to low-level irradiations. Similar cell response probability functions calculated from different experimental data are presented.

  20. Cell-oriented alternatives to dose, quality factor, and dose equivalent for low-level radiation.

    PubMed

    Sondhaus, C A; Bond, V P; Feinendegen, L E

    1990-07-01

    Randomly occurring energy deposition events produced by low levels of ionizing radiation interacting with tissue deliver variable amounts of energy to sensitive target volumes within a small fraction of the tissue cell population. A model is described in which an experimentally derived function relating event size to cell response probability operates mathematically on the microdosimetric event size distribution characterizing a given irradiation and thus determines the total fractional number of responding cells; this fraction measures the effectiveness of the given radiation. Applying this cell response or hit size effectiveness function (HSEF) to different radiations and normalizing to equal numbers of responses produced by each radiation should define its radiation quality, or relative effectiveness, on a more nearly absolute basis than do the absorbed dose and dose equivalent, both of which are confounded when applied to low-level irradiations. Similar cell response probability functions calculated from different experimental data are presented.

  1. Impact of the Fukushima nuclear accident on background radiation doses measured by control dosimeters in Japan.

    PubMed

    Romanyukha, Alexander; King, David L; Kennemur, Lisa K

    2012-05-01

    After the 9.0 magnitude earthquake and subsequent massive tsunami on 11 March 2011 in Japan, several reactors at the Fukushima Daiichi Nuclear Power Plant suffered severe damage. There was immediate participation of U.S. Navy vessels and other United States Department of Defense (DoD) teams that were already in the area at the time of the disaster or arrived shortly thereafter. The correct determination of occupational dose equivalent requires estimation of the background dose component measured by control dosimeters, which is subsequently subtracted from the total dose equivalent measured by personal dosimeters. The purpose of the control dosimeters is to determine the amount of radiation dose equivalent that has accumulated on the dosimeter from background or other non-occupational sources while they are in transit or being stored. Given the release of radioactive material and potential exposure to radiation from the Fukushima Daiichi Nuclear Power Plant and the process by which the U.S. Navy calculates occupational exposure to ionizing radiation, analysis of pre- and post-event control dosimeters is warranted. Several hundred historical dose records from the Naval Dosimetry Center (NDC) database were analyzed and compared with the post-accident dose equivalent data of control dosimeters. As result, it was shown that the dose contribution of the radiation and released radiological materials from the Fukushima nuclear accident to background radiation doses is less than 0.375 μSv d for shallow and deep photon dose equivalent. There is no measurable effect on neutron background exposure. The latter has at least two important conclusions. First, the NDC can use doses measured by control dosimeters at issuing sites in Japan for determination of personnel dose equivalents; second, the dose data from control dosimeters prior to and after the Fukushima accident may be used to assist in dose reconstruction of non-radiological (non-badged) personnel at these locations.

  2. Occupational radiation dose estimation for Finnish aircraft cabin attendants.

    PubMed

    Kojo, Katja; Aspholm, Rafael; Auvinen, Anssi

    2004-04-01

    The objective of this study was to develop a method for assessing dose radiation on the basis of individual flight history and to estimate whether this method is applicable for cabin attendants without flight log data. Questionnaire data were collected to determine attendants' flight history covering up to three decades. Finnair timetables and an expert panel of pilots were used to determine one to four representative flights in five route categories. The cumulative career and annual doses were calculated on the basis of the flight histories and route-specific exposure data. Questionnaire data were obtained from 544 flight attendants. The mean number of active workyears was 10.5 (range 0-30) years, and the mean cosmic radiation dose was 3.2 (range 0-9.5) mSv per active workyear. The mean cumulative career dose for all the cabin attendants was 34.0 (range 0-156.8) mSv. If no flight log data are available, survey data are needed for individual dose estimation when possible radiation effects on cabin crew are evaluated in epidemiologic studies. This method provides a crude procedure for assessing cosmic radiation exposure among attendants when survey data are missing.

  3. Management of pediatric radiation dose using Agfa computed radiography.

    PubMed

    Schaetzing, R

    2004-10-01

    Radiation dose to patients and its management have become important considerations in modern radiographic imaging procedures, but they acquire particular significance in the imaging of children. Because of their longer life expectancy, children exposed to radiation are thought to have a significantly increased risk of radiation-related late sequelae compared to adults first exposed to radiation later in life. Therefore, current clinical thinking dictates that dose in pediatric radiography be minimized, while simultaneously ensuring sufficient diagnostic information in the image, and reducing the need for repeat exposures. Dose management obviously starts with characterization and control of the exposure technique. However, it extends farther through the imaging chain to the acquisition system, and even to the image processing techniques used to optimize acquired images for display. Further, other factors, such as quality control procedures and the ability to handle special pediatric procedures, like scoliosis exams, also come into play. The need for dose management in modern radiography systems has spawned a variety of different solutions, some of which are similar across different manufacturers, and some of which are unique. This paper covers the techniques used in Agfa Computed Radiography (CR) systems to manage dose in a pediatric environment.

  4. Consideration of the radiation dose delivered away from the treatment field to patients in radiotherapy

    PubMed Central

    Taylor, Michael L.; Kron, Tomas

    2011-01-01

    Radiation delivery to cancer patients for radiotherapy is invariably accompanied by unwanted radiation to other parts of the patient’s body. Traditionally, considerable effort has been made to calculate and measure the radiation dose to the target as well as to nearby critical structures. Only recently has attention been focused also on the relatively low doses that exist far from the primary radiation beams. In several clinical scenarios, such doses have been associated with cardiac toxicity as well as an increased risk of secondary cancer induction. Out-of-field dose is a result of leakage and scatter and generally difficult to predict accurately. The present review aims to present existing data, from measurements and calculations, and discuss its implications for radiotherapy. PMID:21731221

  5. Do changes in biomarkers from space radiation reflect dose or risk?

    NASA Astrophysics Data System (ADS)

    Brooks, A.

    The space environment is made up of many different kinds of radiation so that the proper use of biomarkers is essential to estimate radiation risk. This presentation will evaluate differences between biomarkers of dose and risk and demonstrate why they should not be confused following radiation exposures in deep space. Dose is a physical quantity, while risk is a biological quantity. Many examples exist w ereh dose or changes in biomarkers of dose are inappropriately used as predictors of risk. Without information on the biology of the system, the biomarkers of dose provide little help in predicting risk in tissues or radiation exposure types where no excess risk can be demonstrated. Many of these biomarkers of dose only reflect changes in radiation dose or exposure. However, these markers are often incorrectly used to predict risk. For example, exposure of the trachea or of the deep lung to high-LET alpha particles results in similar changes in the biomarker chromosome damage in these two tissues. Such an observation would predict that the risk for cancer induction would be similar in these two tissues. It has been noted , however, that there has never been a tracheal tumor observed in rats that inhaled radon, but with the same exposure, large numbers of tumors were produced in the deep lung. The biology of the different tissues is the major determinant of the risk rather than the radiation dose. Recognition of this fact has resulted in the generation of tissue weighting factors for use in radiation protection. When tissue weighting factors are used the values derived are still called "dose". It is important to recognize that tissue specific observations have been corrected to reflect risk, and therefore should no longer be viewed as dose. The relative biological effectiveness (RBE) is also used to estimate radiation risk. The use of biomarkers to derive RBE is a difficult since it involves the use of a biological response to a standard low-LET reference radiation

  6. Methodology for Estimating Radiation Dose Rates to Freshwater Biota Exposed to Radionuclides in the Environment

    SciTech Connect

    Blaylock, B.G.

    1993-01-01

    The purpose of this report is to present a methodology for evaluating the potential for aquatic biota to incur effects from exposure to chronic low-level radiation in the environment. Aquatic organisms inhabiting an environment contaminated with radioactivity receive external radiation from radionuclides in water, sediment, and from other biota such as vegetation. Aquatic organisms receive internal radiation from radionuclides ingested via food and water and, in some cases, from radionuclides absorbed through the skin and respiratory organs. Dose rate equations, which have been developed previously, are presented for estimating the radiation dose rate to representative aquatic organisms from alpha, beta, and gamma irradiation from external and internal sources. Tables containing parameter values for calculating radiation doses from selected alpha, beta, and gamma emitters are presented in the appendix to facilitate dose rate calculations. The risk of detrimental effects to aquatic biota from radiation exposure is evaluated by comparing the calculated radiation dose rate to biota to the U.S. Department of Energy's (DOE's) recommended dose rate limit of 0.4 mGy h{sup -1} (1 rad d{sup -1}). A dose rate no greater than 0.4 mGy h{sup -1} to the most sensitive organisms should ensure the protection of populations of aquatic organisms. DOE's recommended dose rate is based on a number of published reviews on the effects of radiation on aquatic organisms that are summarized in the National Council on Radiation Protection and Measurements Report No. 109 (NCRP 1991). The literature identifies the developing eggs and young of some species of teleost fish as the most radiosensitive organisms. DOE recommends that if the results of radiological models or dosimetric measurements indicate that a radiation dose rate of 0.1 mGy h{sup -1} will be exceeded, then a more detailed evaluation of the potential ecological consequences of radiation exposure to endemic populations should be

  7. Gamma-radiation-induced corrosion of aluminum alloy: low dose effect

    NASA Astrophysics Data System (ADS)

    Kanjana, K.; Ampornrat, P.; Channuie, J.

    2017-06-01

    Gamma-radiation-induced corrosion of aluminium alloy 6061 (AA6061) immersed in demineralized water was studied at radiation dose up to 206 kGy using a Co-60 gamma radiation source. The surface morphology and chemical composition of the oxide produced on the post-irradiated samples were investigated using SEM-EDS. The electrochemical corrosion potentials (Ecorr ) of the post-irradiated samples were measured. The corrosion behavior of AA6061 appeared to be dose dependent under the experimental conditions. A dramatic change in surface morphology was observed in the samples exposed to gamma radiation at 206 kGy. At this radiation dose the aluminium oxide scale developed can be clearly seen. The results from electrochemical corrosion tests have shown that the corrosion potentials (Ecorr ) can be undoubtedly decreased by gamma irradiation, giving corrosion rate of 7 × 10-4 mm/yr.

  8. Absorbed dose thresholds and absorbed dose rate limitations for studies of electron radiation effects on polyetherimides

    NASA Technical Reports Server (NTRS)

    Long, Edward R., Jr.; Long, Sheila Ann T.; Gray, Stephanie L.; Collins, William D.

    1989-01-01

    The threshold values of total absorbed dose for causing changes in tensile properties of a polyetherimide film and the limitations of the absorbed dose rate for accelerated-exposure evaluation of the effects of electron radiation in geosynchronous orbit were studied. Total absorbed doses from 1 kGy to 100 MGy and absorbed dose rates from 0.01 MGy/hr to 100 MGy/hr were investigated, where 1 Gy equals 100 rads. Total doses less than 2.5 MGy did not significantly change the tensile properties of the film whereas doses higher than 2.5 MGy significantly reduced elongation-to-failure. There was no measurable effect of the dose rate on the tensile properties for accelerated electron exposures.

  9. Implications of Intercellular Signaling for Radiation Therapy: A Theoretical Dose-Planning Study

    SciTech Connect

    McMahon, Stephen J.; McGarry, Conor K.; Butterworth, Karl T.; O'Sullivan, Joe M.; Hounsell, Alan R.; Prise, Kevin M.

    2013-12-01

    Purpose: Recent in vitro results have shown significant contributions to cell killing from signaling effects at doses that are typically used in radiation therapy. This study investigates whether these in vitro observations can be reconciled with in vivo knowledge and how signaling may have an impact on future developments in radiation therapy. Methods and Materials: Prostate cancer treatment plans were generated for a series of 10 patients using 3-dimensional conformal therapy, intensity modulated radiation therapy (IMRT), and volumetric modulated arc therapy techniques. These plans were evaluated using mathematical models of survival following modulated radiation exposures that were developed from in vitro observations and incorporate the effects of intercellular signaling. The impact on dose–volume histograms and mean doses were evaluated by converting these survival levels into “signaling-adjusted doses” for comparison. Results: Inclusion of intercellular communication leads to significant differences between the signalling-adjusted and physical doses across a large volume. Organs in low-dose regions near target volumes see the largest increases, with mean signaling-adjusted bladder doses increasing from 23 to 33 Gy in IMRT plans. By contrast, in high-dose regions, there is a small decrease in signaling-adjusted dose due to reduced contributions from neighboring cells, with planning target volume mean doses falling from 74 to 71 Gy in IMRT. Overall, however, the dose distributions remain broadly similar, and comparisons between the treatment modalities are largely unchanged whether physical or signaling-adjusted dose is compared. Conclusions: Although incorporating cellular signaling significantly affects cell killing in low-dose regions and suggests a different interpretation for many phenomena, their effect in high-dose regions for typical planning techniques is comparatively small. This indicates that the significant signaling effects observed in vitro

  10. Dose build up correction for radiation monitors in high-energy bremsstrahlung photon radiation fields.

    PubMed

    Nair, Haridas G; Nayak, M K; Dev, Vipin; Thakkar, K K; Sarkar, P K; Sharma, D N

    2006-01-01

    Conventional radiation monitors have been found to underestimate the personal dose equivalent in the high-energy bremsstrahlung photon radiation fields encountered near electron storage rings. Depth-dose measurements in a water phantom were carried out with a radiation survey meter in the bremsstrahlung photon radiation fields from a 450 MeV electron storage ring to find out the magnitude of the underestimation. Dose equivalent indicated by the survey meter was found to build up with increase in thickness of water placed in front of the meter up to certain depth and then reduce with further increase in thickness. A dose equivalent build up factor was estimated from the measurements. An absorbed dose build up factor in a water phantom was also estimated from calculations performed using the Monte Carlo codes, EGS-4 and EGSnrc. The calculations are found to be in very good agreement with the measurements. The studies indicate inadequacy of commercially available radiation monitors for radiation monitoring within shielded enclosures and in streaming high-energy photon radiation fields from electron storage rings, and the need for proper correction for use in such radiation fields.

  11. Changing Attitude Toward Radiation Carcinogenesis and Prospects for Novel Low-Dose Radiation Treatments.

    PubMed

    Socol, Yehoshua; Welsh, James S

    2016-12-01

    All procedures involving ionizing radiation, whether diagnostic or therapeutic, are subject to strict regulation, and public concerns have been raised about even the low levels of radiation exposures involved in diagnostic imaging. During the last 2 decades, there are signs of more balanced attitude to ionizing radiation hazards, as opposed to the historical "radiophobia." The linear no-threshold hypothesis, based on the assumption that every radiation dose increment constitutes increased cancer risk for humans, is increasingly debated. In particular, the recent memorandum of the International Commission on Radiological Protection admits that the linear no-threshold hypothesis predictions at low doses (that International Commission on Radiological Protection itself has used and continues to use) are "speculative, unproven, undetectable, and 'phantom'." Moreover, numerous experimental, ecological, and epidemiological studies suggest that low doses of ionizing radiation may actually be beneficial to human health. Although these advances in scientific understanding have not yet yielded significant changes in radiation regulation and policy, we are hopeful such changes may happen in the relatively near future. This article reviews the present status of the low-dose radiation hazard debate and outlines potential opportunities in the field of low-dose radiation therapy. © The Author(s) 2015.

  12. A Radiation Dose Reduction Technology to Improve Patient Safety During Cardiac Catheterization Interventions.

    PubMed

    Bracken, John A; Mauti, Maria; Kim, Michael S; Messenger, John C; Carroll, John D

    2015-10-01

    A novel radiation dose reduction technology was evaluated in a cardiac catheterization laboratory during routine clinical care to determine if it could reduce radiation dose to patients undergoing coronary angiography and percutaneous coronary intervention. These results were compared to patients undergoing similar procedures in a cardiac catheterization laboratory without this technology. There is a safety priority in clinical care to reduce X-ray radiation dose to patients in order to lower the risk of deterministic and stochastic effects. Dose reduction technologies must be verified in clinical settings to prove if they reduce X-ray radiation dose and to what extent. Radiation dose data and procedure characteristics of 268 consecutive patients were collected and analyzed from a cardiac catheterization laboratory with dose reduction technology installed (referred to as Lab A, n = 135) and from a cardiac catheterization laboratory without this technology (referred as Lab B, n = 133). For diagnostic procedures, the median total dose-area product in Lab A was reduced by 46% (P < 0.0001) compared to Lab B, with no differences in terms of body mass index (P = 0.180), total fluoroscopy times (P = 1), number of acquired images (P = 0.920), and contrast medium (P = 0.660). For interventional procedures, the median total dose-area product in Lab A was reduced by 34% (P = 0.015) compared to Lab B, with no differences in terms of body mass index (P = 0.665), total fluoroscopy times (P = 0.765), number of acquired images (P = 0.923), and contrast medium (P = 0.969). This new dose reduction technology significantly reduces X-ray radiation dose without affecting fluoroscopy time, number of images, and contrast medium used during diagnostic and interventional coronary procedures. © 2015, Wiley Periodicals, Inc.

  13. Radiation dose dependent change in physiochemical, mechanical and barrier properties of guar gum based films.

    PubMed

    Saurabh, Chaturbhuj K; Gupta, Sumit; Bahadur, Jitendra; Mazumder, S; Variyar, Prasad S; Sharma, Arun

    2013-11-06

    Mechanical and water vapor barrier properties of biodegradable films prepared from radiation processed guar gum were investigated. Films prepared from GG irradiated up to 500 Gy demonstrated significantly higher tensile strength as compared to non-irradiated control films. This improvement in tensile strength observed was demonstrated to be due to the ordering of polymer structures as confirmed by small angle X-ray scattering analysis. Exposure to doses higher than 500 Gy, however, resulted in a dose dependent decrease in tensile strength. A dose dependent decrease in puncture strength with no significant differences in the percent elongation was also observed at all the doses studied. Water vapor barrier properties of films improved up to 15% due to radiation processing. Radiation processing at lower doses for improving mechanical and barrier properties of guar based packaging films is demonstrated here for the first time.

  14. Comprehensive assessment of radiation dose estimates for the CORE320 study.

    PubMed

    Rybicki, Frank J; Mather, Richard T; Kumamaru, Kanako K; Brinker, Jeffrey; Chen, Marcus Y; Cox, Christopher; Matheson, Matthew B; Dewey, Marc; DiCarli, Marcelo F; Miller, Julie M; Geleijns, Jacob; George, Richard T; Paul, Narinder; Texter, John; Vavere, Andrea; Yaw, Tan Swee; Lima, Joao A C; Clouse, Melvin E

    2015-01-01

    OBJECTIVE. The purpose of this study was to comprehensively study estimated radiation doses for subjects included in the main analysis of the Combined Non-invasive Coronary Angiography and Myocardial Perfusion Imaging Using 320 Detector Computed Tomography (CORE320) study ( ClinicalTrials.gov identifier NCT00934037), a clinical trial comparing combined CT angiography (CTA) and perfusion CT with the reference standard catheter angiography plus myocardial perfusion SPECT. SUBJECTS AND METHODS. Prospectively acquired data on 381 CORE320 subjects were analyzed in four groups of testing related to radiation exposure. Radiation dose estimates were compared between modalities for combined CTA and perfusion CT with respect to covariates known to influence radiation exposure and for the main clinical outcomes defined by the trial. The final analysis assessed variations in radiation dose with respect to several factors inherent to the trial. RESULTS. The mean radiation dose estimate for the combined CTA and perfusion CT protocol (8.63 mSv) was significantly (p < 0.0001 for both) less than the average dose delivered from SPECT (10.48 mSv) and the average dose from diagnostic catheter angiography (11.63 mSv). There was no significant difference in estimated CTA-perfusion CT radiation dose for subjects who had false-positive or false-negative results in the CORE320 main analyses in a comparison with subjects for whom the CTA-perfusion CT findings were in accordance with the reference standard SPECT plus catheter angiographic findings. CONCLUSION. Radiation dose estimates from CORE320 support clinical implementation of a combined CT protocol for assessing coronary anatomy and myocardial perfusion.

  15. Compelling Issues Compounding the Understanding of Low Dose Radiation Effects: But Do They Matter?

    PubMed

    Morgan, William F

    2016-03-01

    Recent advances in low dose radiation research have raised a number of compelling issues that have compounded the understanding of low dose radiation effects. Here some of them are outlined: the linear no-threshold model for predicting effects at low radiation doses, dose rate effectiveness factor, attributability, and public perception of low dose radiation effects. The impact of changes in any of these hotly debated issues on radiation protection is considered.

  16. Detecting ionizing radiation with optical fibers down to biomedical doses

    NASA Astrophysics Data System (ADS)

    Avino, S.; D'Avino, V.; Giorgini, A.; Pacelli, R.; Liuzzi, R.; Cella, L.; De Natale, P.; Gagliardi, G.

    2013-10-01

    We report on a passive ionizing radiation sensor based on a fiber-optic resonant cavity interrogated by a high resolution interferometric technique. After irradiation in clinical linear accelerators, we observe significant variations of the fiber thermo-optic coefficient. Exploiting this effect, we demonstrate an ultimate detection limit of 160 mGy with an interaction volume of only 6 × 10-4 mm3. Thanks to its reliability, compactness, and sensitivity at biomedical dose levels, our system lends itself to real applications in radiation therapy procedures as well as in radiation monitoring and protection in medicine, aerospace, and nuclear power plants.

  17. Radiation dose due to radon and thoron progeny inhalation in high-level natural radiation areas of Kerala, India.

    PubMed

    Omori, Yasutaka; Tokonami, Shinji; Sahoo, Sarata Kumar; Ishikawa, Tetsuo; Sorimachi, Atsuyuki; Hosoda, Masahiro; Kudo, Hiromi; Pornnumpa, Chanis; Nair, Raghu Ram K; Jayalekshmi, Padmavaty Amma; Sebastian, Paul; Akiba, Suminori

    2017-03-20

    In order to evaluate internal exposure to radon and thoron, concentrations for radon, thoron, and thoron progeny were measured for 259 dwellings located in high background radiation areas (HBRAs, outdoor external dose: 3-5 mGy y(-1)) and low background radiation areas (control areas, outdoor external dose: 1 mGy y(-1)) in Karunagappally Taluk, Kerala, India. The measurements were conducted using passive-type radon-thoron detectors and thoron progeny detectors over two six-month measurement periods from June 2010 to June 2011. The results showed no major differences in radon and thoron progeny concentrations between the HBRAs and the control areas. The geometric mean of the annual effective dose due to radon and thoron was calculated as 0.10 and 0.44 mSv, respectively. The doses were small, but not negligible compared with the external dose in the two areas.

  18. Ambient dose and dose rate measurements in the vicinity of Elekta Precise accelerators for radiation therapy.

    PubMed

    Zutz, H; Hupe, O

    2014-12-01

    In radiation therapy, commercially available medical linear accelerators (LINACs) are used. At high primary beam energies in the 10-MeV range, the leakage dose of the accelerator head and the backscatter from the room walls, the air and the patient become more important. Therefore, radiation protection measurements of photon dose rates in the treatment room and in the maze are performed to quantify the radiation field. Since the radiation of the LINACs is usually pulsed with short radiation pulse durations in the microsecond range, there are problems with electronic dose (rate) meters commonly used in radiation protection. In this paper measurements with ionisation chambers are presented and electronic dosemeters are used for testing at selected positions. The measured time-averaged dose rate ranges from a few microsieverts per hour in the maze to some millisieverts per hour in the vicinity of the accelerator head and up to some sieverts per hour in the blanked primary beam and several hundred sieverts per hour in the direct primary beam.

  19. Effect of radiation protraction on BED in the case of large fraction dose

    SciTech Connect

    Kuperman, V. Y.

    2013-08-15

    Purpose: To investigate the effect of radiation protraction on biologically effective dose (BED) in the case when dose per fraction is significantly greater than the standard dose of 2 Gy.Methods: By using the modified linear-quadratic model with monoexponential repair, the authors investigate the effect of long treatment times combined with dose escalation.Results: The dependences of the protraction factor and the corresponding BED on fraction time were determined for different doses per fraction typical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT). In the calculations, the authors consider changes in the BED to the normal tissue under the condition of fixed BED to the target.Conclusion: The obtained results demonstrate that simultaneous increase in fraction time and dose per fraction can be beneficial for SRS and SBRT because of the related decrease in BED to normal structures while BED to the target is fixed.

  20. Biological equivalent dose studies for dose escalation in the stereotactic synchrotron radiation therapy clinical trials

    SciTech Connect

    Prezado, Y.; Fois, G.; Edouard, M.; Nemoz, C.; Renier, M.; Requardt, H.; Esteve, F.; Adam, JF.; Elleaume, H.; Bravin, A.

    2009-03-15

    Synchrotron radiation is an innovative tool for the treatment of brain tumors. In the stereotactic synchrotron radiation therapy (SSRT) technique a radiation dose enhancement specific to the tumor is obtained. The tumor is loaded with a high atomic number (Z) element and it is irradiated in stereotactic conditions from several entrance angles. The aim of this work was to assess dosimetric properties of the SSRT for preparing clinical trials at the European Synchrotron Radiation Facility (ESRF). To estimate the possible risks, the doses received by the tumor and healthy tissues in the future clinical conditions have been calculated by using Monte Carlo simulations (PENELOPE code). The dose enhancement factors have been determined for different iodine concentrations in the tumor, several tumor positions, tumor sizes, and different beam sizes. A scheme for the dose escalation in the various phases of the clinical trials has been proposed. The biological equivalent doses and the normalized total doses received by the skull have been calculated in order to assure that the tolerance values are not reached.

  1. Experimental investigation of radiation effect on erbium-ytterbium co-doped fiber amplifier for space optical communication in low-dose radiation environment.

    PubMed

    Ma, Jing; Li, Mi; Tan, Liying; Zhou, Yanping; Yu, Siyuan; Ran, Qiwen

    2009-08-31

    High power erbium-ytterbium co-doped fiber amplifier (EYDFA) has been radiated to the dose of 50 krad at the dose rate of 40 rad/s. Some key parameters have been measured to investigate the radiation effect on the EYDFA for space optical communication. Considering the dose of 50 krad is big enough to the most of low-dose radiation environment, these experimental results will be a good reference for the low-dose inter-satellite optical communication designers.

  2. Lack of protective effect of thromboxane synthetase inhibitor (CGS-13080) on single dose radiated canine intestine.

    PubMed

    Barter, J F; Marlow, D; Kamath, R K; Harbert, J; Torrisi, J R; Barnes, W A; Potkul, R K; Newsome, J T; Delgado, G

    1991-03-01

    The effect of a thromboxane A2 synthetase inhibitor (CGS-13080) on canine intestine was studied using a single dose of radiation, and radioactive microspheres were used to determine resultant blood flow. Thromboxane A2 causes vasospasm and platelet aggregation and may play a dominant role in radiation injury. However, there was no effect on the intestinal blood flow diminution occurring after radiation in this laboratory model using this thromboxane A2 synthetase inhibitor.

  3. Lack of protective effect of thromboxane synthetase inhibitor (CGS-13080) on single dose radiated canine intestine

    SciTech Connect

    Barter, J.F.; Marlow, D.; Kamath, R.K.; Harbert, J.; Torrisi, J.R.; Barnes, W.A.; Potkul, R.K.; Newsome, J.T.; Delgado, G. )

    1991-03-01

    The effect of a thromboxane A2 synthetase inhibitor (CGS-13080) on canine intestine was studied using a single dose of radiation, and radioactive microspheres were used to determine resultant blood flow. Thromboxane A2 causes vasospasm and platelet aggregation and may play a dominant role in radiation injury. However, there was no effect on the intestinal blood flow diminution occurring after radiation in this laboratory model using this thromboxane A2 synthetase inhibitor.

  4. NAIRAS aircraft radiation model development, dose climatology, and initial validation

    PubMed Central

    Mertens, Christopher J; Meier, Matthias M; Brown, Steven; Norman, Ryan B; Xu, Xiaojing

    2013-01-01

    [1] The Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) is a real-time, global, physics-based model used to assess radiation exposure to commercial aircrews and passengers. The model is a free-running physics-based model in the sense that there are no adjustment factors applied to nudge the model into agreement with measurements. The model predicts dosimetric quantities in the atmosphere from both galactic cosmic rays (GCR) and solar energetic particles, including the response of the geomagnetic field to interplanetary dynamical processes and its subsequent influence on atmospheric dose. The focus of this paper is on atmospheric GCR exposure during geomagnetically quiet conditions, with three main objectives. First, provide detailed descriptions of the NAIRAS GCR transport and dosimetry methodologies. Second, present a climatology of effective dose and ambient dose equivalent rates at typical commercial airline altitudes representative of solar cycle maximum and solar cycle minimum conditions and spanning the full range of geomagnetic cutoff rigidities. Third, conduct an initial validation of the NAIRAS model by comparing predictions of ambient dose equivalent rates with tabulated reference measurement data and recent aircraft radiation measurements taken in 2008 during the minimum between solar cycle 23 and solar cycle 24. By applying the criterion of the International Commission on Radiation Units and Measurements (ICRU) on acceptable levels of aircraft radiation dose uncertainty for ambient dose equivalent greater than or equal to an annual dose of 1 mSv, the NAIRAS model is within 25% of the measured data, which fall within the ICRU acceptable uncertainty limit of 30%. The NAIRAS model predictions of ambient dose equivalent rate are generally within 50% of the measured data for any single-point comparison. The largest differences occur at low latitudes and high cutoffs, where the radiation dose level is low. Nevertheless, analysis

  5. NAIRAS aircraft radiation model development, dose climatology, and initial validation.

    PubMed

    Mertens, Christopher J; Meier, Matthias M; Brown, Steven; Norman, Ryan B; Xu, Xiaojing

    2013-10-01

    [1] The Nowcast of Atmospheric Ionizing Radiation for Aviation Safety (NAIRAS) is a real-time, global, physics-based model used to assess radiation exposure to commercial aircrews and passengers. The model is a free-running physics-based model in the sense that there are no adjustment factors applied to nudge the model into agreement with measurements. The model predicts dosimetric quantities in the atmosphere from both galactic cosmic rays (GCR) and solar energetic particles, including the response of the geomagnetic field to interplanetary dynamical processes and its subsequent influence on atmospheric dose. The focus of this paper is on atmospheric GCR exposure during geomagnetically quiet conditions, with three main objectives. First, provide detailed descriptions of the NAIRAS GCR transport and dosimetry methodologies. Second, present a climatology of effective dose and ambient dose equivalent rates at typical commercial airline altitudes representative of solar cycle maximum and solar cycle minimum conditions and spanning the full range of geomagnetic cutoff rigidities. Third, conduct an initial validation of the NAIRAS model by comparing predictions of ambient dose equivalent rates with tabulated reference measurement data and recent aircraft radiation measurements taken in 2008 during the minimum between solar cycle 23 and solar cycle 24. By applying the criterion of the International Commission on Radiation Units and Measurements (ICRU) on acceptable levels of aircraft radiation dose uncertainty for ambient dose equivalent greater than or equal to an annual dose of 1 mSv, the NAIRAS model is within 25% of the measured data, which fall within the ICRU acceptable uncertainty limit of 30%. The NAIRAS model predictions of ambient dose equivalent rate are generally within 50% of the measured data for any single-point comparison. The largest differences occur at low latitudes and high cutoffs, where the radiation dose level is low. Nevertheless, analysis

  6. Pathology effects at radiation doses below those causing increased mortality

    NASA Technical Reports Server (NTRS)

    Carnes, Bruce A.; Gavrilova, Natalia; Grahn, Douglas

    2002-01-01

    Mortality data from experiments conducted at the Argonne National Laboratory (ANL) on the long-term effects of external whole-body irradiation on B6CF(1) mice were used to investigate radiation-induced effects at intermediate doses of (60)Co gamma rays or fission-spectrum neutrons either delivered as a single exposure or protracted over 60 once-weekly exposures. Kaplan-Meier analyses were used to identify the lowest dose in the ANL data (within radiation quality, pattern of exposure, and sex) at which radiation-induced mortality caused by primary tumors could be detected (approximately 1-2 Gy for gamma rays and 10-15 cGy for neutrons). Doses at and below these levels were then examined for radiation-induced shifts in the spectrum of pathology detected at death. To do this, specific pathology events were pooled into larger assemblages based on whether they were cancer, cardiovascular disease or non-neoplastic diseases detected within the lungs and pleura, liver and biliary tract, reproductive organs, or urinary tract. Cancer and cardiovascular disease were further subdivided into categories based on whether they caused death, contributed to death, or were simply observed at death. Counts of how often events falling within each of these combined pathology categories occurred within a mouse were then used as predictor variables in logistic regression to determine whether irradiated mice could be distinguished from control mice. Increased pathology burdens were detected in irradiated mice at doses lower than those causing detectable shifts in mortality-22 cGy for gamma rays and 2 cGy for neutrons. These findings suggest that (1) models based on mortality data alone may underestimate radiation effects, (2) radiation may have adverse health consequences (i.e. elevated health risks) even when mortality risks are not detected, and (3) radiation-induced pathologies other than cancer do occur, and they involve multiple organ systems.

  7. Earth Radiation Budget Experiment - Preliminary seasonal results

    NASA Technical Reports Server (NTRS)

    Barkstrom, Bruce R.; Harrison, Edwin F.; Lee, Robert B., III

    1990-01-01

    Data from the Earth Radiation Budget Satellite (ERBS) and from the operational NOAA-9 satellite being placed in the archive of the earth Radiation Budget Experiment (ERBE) are discussed. The results of the ERBE data validation effort are reviewed along with ERBE solar constant observations and earth-viewing results. The latter include monthly average results for July 1985, annual average clear-sky fluxes, and annual average, zonal, and global results.

  8. Use of EORTC Target Definition Guidelines for Dose-Intensified Salvage Radiation Therapy for Recurrent Prostate Cancer: Results of the Quality Assurance Program of the Randomized Trial SAKK 09/10

    SciTech Connect

    Sassowsky, Manfred; Gut, Philipp; Hölscher, Tobias; Hildebrandt, Guido; Müller, Arndt-Christian; Najafi, Yousef; Kohler, Götz; Kranzbühler, Helmut; Guckenberger, Matthias; Zwahlen, Daniel R.; Azinwi, Ngwa C.; Plasswilm, Ludwig; Takacs, Istvan; Reuter, Christiane; Sumila, Marcin; Manser, Peter; Ost, Piet; Böhmer, Dirk; Pilop, Christiane; Aebersold, Daniel M.; and others

    2013-11-01

    Purpose: Different international target volume delineation guidelines exist and different treatment techniques are available for salvage radiation therapy (RT) for recurrent prostate cancer, but less is known regarding their respective applicability in clinical practice. Methods and Materials: A randomized phase III trial testing 64 Gy vs 70 Gy salvage RT was accompanied by an intense quality assurance program including a site-specific and study-specific questionnaire and a dummy run (DR). Target volume delineation was performed according to the European Organisation for the Research and Treatment of Cancer guidelines, and a DR-based treatment plan was established for 70 Gy. Major and minor protocol deviations were noted, interobserver agreement of delineated target contours was assessed, and dose-volume histogram (DVH) parameters of different treatment techniques were compared. Results: Thirty European centers participated, 43% of which were using 3-dimensional conformal RT (3D-CRT), with the remaining centers using intensity modulated RT (IMRT) or volumetric modulated arc technique (VMAT). The first submitted version of the DR contained major deviations in 21 of 30 (70%) centers, mostly caused by inappropriately defined or lack of prostate bed (PB). All but 5 centers completed the DR successfully with their second submitted version. The interobserver agreement of the PB was moderate and was improved by the DR review, as indicated by an increased κ value (0.59 vs 0.55), mean sensitivity (0.64 vs 0.58), volume of total agreement (3.9 vs 3.3 cm{sup 3}), and decrease in the union volume (79.3 vs 84.2 cm{sup 3}). Rectal and bladder wall DVH parameters of IMRT and VMAT vs 3D-CRT plans were not significantly different. Conclusions: The interobserver agreement of PB delineation was moderate but was improved by the DR. Major deviations could be identified for the majority of centers. The DR has improved the acquaintance of the participating centers with the trial

  9. Radiation effect in mouse skin: Dose fractionation and wound healing

    SciTech Connect

    Gorodetsky, R.; Mou, X.D.; Fisher, D.R.; Taylor, J.M.; Withers, H.R. )

    1990-05-01

    Radiation induced dermal injury was measured by the gain in the physical strength of healing wounds in mouse skin. A sigmoid dose response for the inhibition of wound healing 14 days after surgery was found for single doses of X rays. The sparing of dermal damage from fractionation of the X-ray dose was quantified in terms of the alpha/beta ratio in the linear-quadratic (LQ) model, at a wide range of doses per fraction reaching as low as about 1 Gy. The fit and the appropriateness of the LQ model for the skin wound healing assay was examined with the use of the Fe-plot in which inverse total dose is plotted versus dose per fraction for wound strength isoeffects. The alpha/beta ratio of the skin was about 2.5 Gy (95% confidence of less than +/- 1 Gy) and was appropriate over a dose range of 1 Gy to about 8 Gy. The low alpha/beta value is typical for a late responding tissue. This assay, therefore, has the advantage of measuring and forecasting late radiation responses of the dermis within a short time after irradiation.

  10. Radiation Doses and Associated Risk From the Fukushima Nuclear Accident.

    PubMed

    Ishikawa, Tetsuo

    2017-03-01

    The magnitude of dose due to the Fukushima Daiichi Accident was estimated by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR) 2013 report published in April 2014. Following this, the UNSCEAR white paper, which comprises a digest of new information for the 2013 Fukushima report, was published in October 2015. Another comprehensive report on radiation dose due to the accident is the International Atomic Energy Agency (IAEA) report on the Fukushima Daiichi Accident published in August 2015. Although the UNSCEAR and IAEA publications well summarize doses received by residents, they review only literature published before the end of December 2014 and the end of March 2015, respectively. However, some studies on dose estimation have been published since then. In addition, the UNSCEAR 2013 report states it was likely that some overestimation had been introduced generally by the methodology used by the Committee. For example, effects of decontamination were not considered in the lifetime external dose estimated. Decontamination is in progress for most living areas in Fukushima Prefecture, which could reduce long-term external dose to residents. This article mainly reviews recent English language articles that may add new information to the UNSCEAR and IAEA publications. Generally, recent articles suggest lower doses than those presented by the UNSCEAR 2013 report.

  11. Proton tissue dose for the blood forming organ in human geometry: Isotropic radiation

    NASA Technical Reports Server (NTRS)

    Khandelwal, G. S.; Wilson, J. W.

    1974-01-01

    A computer program is described which calculates doses averaged within five major segments of the blood forming organ in the human body taking into account selfshielding of the detailed body geometry and nuclear star effects for proton radiation of arbitrary energy spectrum (energy less than 1 GeV) and isotropic angular distribution. The dose calculation includes the first term of an asymptotic series expansion of transport theory which is known to converge rapidly for most points in the human body. The result is always a conservative estimate of dose and is given as physical dose (rad) and dose equivalent (rem).

  12. Methods of space radiation dose analysis with applications to manned space systems

    NASA Technical Reports Server (NTRS)

    Langley, R. W.; Billings, M. P.

    1972-01-01

    The full potential of state-of-the-art space radiation dose analysis for manned missions has not been exploited. Point doses have been overemphasized, and the critical dose to the bone marrow has been only crudely approximated, despite the existence of detailed man models and computer codes for dose integration in complex geometries. The method presented makes it practical to account for the geometrical detail of the astronaut as well as the vehicle. Discussed are the major assumptions involved and the concept of applying the results of detailed proton dose analysis to the real-time interpretation of on-board dosimetric measurements.

  13. HOSPITAL PHYSICS: Patient radiation doses from diagnostic radiology

    NASA Astrophysics Data System (ADS)

    Hart, D.

    1996-03-01

    X-ray examinations may be of great benefit but they also carry a slight risk. This article explains how doses to patients are measured and describes how different techniques expose patients to differing amounts of ionizing radiation. These figures are compared with other natural and man-made sources.

  14. Integrated Worker Radiation Dose Assessment for the K Basins

    SciTech Connect

    NELSON, J.V.

    1999-10-27

    This report documents an assessment of the radiation dose workers at the K Basins are expected to receive in the process of removing spent nuclear fuel from the storage basins. The K Basins (K East and K West) are located in the Hanford 100K Area.

  15. ULTRAVIOLET RADIATION DOSE AND AMPHIBIAN DISTRIBUTIONS IN NATIONAL PARKS

    EPA Science Inventory

    Ultraviolet Radiation Dose and Amphibian Distributions in National Parks. Diamond, S. A., Detenbeck, N. E., USEPA, Duluth, MN, USA, Bradford, D. F., USEPA, Las Vegas, NV, USA, Trenham, P. C., University of California, Davis, CA., USA, Adams, M. J., Corn, P. S., Hossack, B., USGS,...

  16. ULTRAVIOLET RADIATION DOSE AND AMPHIBIAN DISTRIBUTIONS IN NATIONAL PARKS

    EPA Science Inventory

    Ultraviolet Radiation Dose and Amphibian Distributions in National Parks. Diamond, S. A., Detenbeck, N. E., USEPA, Duluth, MN, USA, Bradford, D. F., USEPA, Las Vegas, NV, USA, Trenham, P. C., University of California, Davis, CA., USA, Adams, M. J., Corn, P. S., Hossack, B., USGS,...

  17. Estimation of effective dose and radiation risk in pediatric barium studies procedures.

    PubMed

    Sulieman, A; Elhag, B; Alkhorayef, M; Babikir, E; Theodorou, K; Kappas, C; Bradley, D

    2017-07-21

    The objectives of this study are to assess pediatric radiation exposure in certain barium studies and to quantify the organ and effective doses and radiation risk resultant from patients' irradiation. A total of 69 pediatric barium studies for upper and lower gastrointestinal tract. Patients' radiation dose was quantified in terms of Entrance surface air kerma (ESAKs) using exposure parameters and DosCal software. Organ and effective doses (E) were extrapolated using national Radiological Protection Board software (NRPB-R279). The mean ± (SD) and the range of patient doses per procedure were 3.7 ± 0.4 (1.0-13.0)mGy, 7.4 ± 1.7(5.5-8.0)mGy and 1.4 ± 0.9 (0.5-3.6)mGy for barium meal, swallow and enema, respectively. The mean effective doses were 0.3 ± 0.03 (0.08-1.1)mSv, 0.2 ± 1.6 (0.44-0.7)mSv and 0.3 ± 0.9 (0.1-0.8)mSv at the same order. The radiation dose were higher compared to previous studies. Therefore, pediatrics are exposed to avoidable radiation exposure. Certain optimization measures are recommended along with establishing national diagnostic reference level (DRL) to reduce the radiation risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Clinical usefulness of the management and delivery of radiation dose-distribution images using the Internet.

    PubMed

    Nakagawa, K; Onogi, Y; Aoki, Y; Kozuka, T; Ohtomo, K

    1998-01-01

    Dose distribution images in radiation therapy play important roles in the management of cancer patients. To date, hard copies of these images have been stored for referral by radiation oncologists as needed. In most cases, these images are not available to medical personnel outside the radiation oncology department. We have developed a means to access these dose distribution images from the hospital via the World-Wide Web (WWW). A screen snapshot of a dose distribution image on the CRT of a treatment planning unit is copied to the WWW server and converted to a GIF (graphic interchange format) image. Similarly, we can register dose volume histograms and digitally reconstructed radiographs (DRR) on the WWW. Medical personnel can view these images through the WWW browser from anywhere in the hospital. As a result, radiation oncologists are given detailed information on target definition in treatment planning by expert physicians. The system also helps co-medical personnel in understanding dose distribution and predicting radiation injury. At the same time, it actualizes an electronic archive of dose distribution images, which is a database for quick and reliable review, evaluation, and comparison of treatment plans. This technique also fosters closer relationships among radiation oncologists, physicians, and co-medical personnel.

  19. Estimated ultraviolet radiation doses in wetlands in six national parks

    USGS Publications Warehouse

    Diamond, S.A.; Trenham, P.C.; Adams, Michael J.; Hossack, B.R.; Knapp, R.A.; Stark, L.; Bradford, D.; Corn, P.S.; Czarnowski, K.; Brooks, P.D.; Fagre, D.B.; Breen, B.; Dentenbeck, N.E.; Tonnessen, K.

    2005-01-01

    Ultraviolet-B radiation (UV-B, 280–320-nm wavelengths) doses were estimated for 1024 wetlands in six national parks: Acadia (Acadia), Glacier (Glacier), Great Smoky Mountains (Smoky), Olympic (Olympic), Rocky Mountain (Rocky), and Sequoia/Kings Canyon (Sequoia). Estimates were made using ground-based UV-B data (Brewer spectrophotometers), solar radiation models, GIS tools, field characterization of vegetative features, and quantification of DOC concentration and spectral absorbance. UV-B dose estimates were made for the summer solstice, at a depth of 1 cm in each wetland. The mean dose across all wetlands and parks was 19.3 W-h m−2 (range of 3.4–32.1 W-h m−2). The mean dose was lowest in Acadia (13.7 W-h m−2) and highest in Rocky (24.4 W-h m−2). Doses were significantly different among all parks. These wetland doses correspond to UV-B flux of 125.0 μW cm−2 (range 21.4–194.7 μW cm−2) based on a day length, averaged among all parks, of 15.5 h. Dissolved organic carbon (DOC), a key determinant of water-column UV-B flux, ranged from 0.6 (analytical detection limit) to 36.7 mg C L−1 over all wetlands and parks, and reduced potential maximal UV-B doses at 1-cm depth by 1%–87 %. DOC concentration, as well as its effect on dose, was lowest in Sequoia and highest in Acadia (DOC was equivalent in Acadia, Glacier, and Rocky). Landscape reduction of potential maximal UV-B doses ranged from zero to 77% and was lowest in Sequoia. These regional differences in UV-B wetland dose illustrate the importance of considering all aspects of exposure in evaluating the potential impact of UV-B on aquatic organisms.

  20. Space radiation dose estimates on the surface of Mars.

    PubMed

    Simonsen, L C; Nealy, J E; Townsend, L W; Wilson, J W

    1990-01-01

    A future goal of the U.S. space program is a commitment to the manned exploration and habitation of Mars. An important consideration of such missions is the exposure of crew members to the damaging effects of ionizing radiation from high-energy galactic cosmic ray fluxes and solar proton flares. The crew will encounter the most harmful radiation environment in transit to Mars from which they must be adequately protected. However, once on the planet's surface, the Martian environment should provide a significant amount of protection from free-space radiative fluxes. In current Mars scenario descriptions, the crew flight time to Mars is estimated to be anywhere from 7 months to over a year each way, with stay times on the surface ranging from 20 days to 2 years. To maintain dose levels below established astronaut limits, dose estimates need to be determined for the entire mission length. With extended crew durations on the surface anticipated, the characterization of the Mars radiation environment is important in assessing all radiation protection requirements. This synopsis focuses on the probable doses incurred by surface inhabitants from the transport of galactic cosmic rays and solar protons through the Mars atmosphere.

  1. Differentially Expressed Genes Associated with Low-Dose Gamma Radiation

    NASA Astrophysics Data System (ADS)

    Hegyesi, Hargita; Sándor, Nikolett; Schilling, Boglárka; Kis, Enikő; Lumniczky, Katalin; Sáfrány, Géza

    We have studied low dose radiation induced gene expression alterations in a primary human fibroblast cell line using Agilent's whole human genome microarray. Cells were irradiated with 60Co γ-rays (0; 0.1; 0.5 Gy) and 2 hours later total cellular RNA was isolated. We observed differential regulation of approximately 300-500 genes represented on the microarray. Of these, 126 were differentially expressed at both doses, among them significant elevation of GDF-15 and KITLG was confirmed by qRT-PCR. Based on the transcriptional studies we selected GDF-15 to assess its role in radiation response, since GDF-15 is one of the p53 gene targets and is believed to participate in mediating p53 activities. First we confirmed gamma-radiation induced dose-dependent changes in GDF-15 expression by qRT-PCR. Next we determined the effect of GDF-15 silencing on radiosensitivity. Four GDF-15 targeting shRNA expressing lentiviral vectors were transfected into immortalized human fibroblast cells. We obtained efficient GDF-15 silencing in one of the four constructs. RNA interference inhibited GDF-15 gene expression and enhanced the radiosensitivity of the cells. Our studies proved that GDF-15 plays an essential role in radiation response and may serve as a promising target in radiation therapy.

  2. Scattered radiation doses to some critical organs during pediatric radiotherapy.

    PubMed

    Agard, E T; Ehlers, G; Kirchberg, S

    1985-04-01

    The levels of scattered radiation doses imparted to the eyes, thyroid and gonads of pediatric patients treated with orthovoltage radiation (300 kVp, 2.0 mmCu HVL) and with a 4-MV linear accelerator, were determined by making thermoluminescent dosimeter (TLD) measurements in three paraffin phantoms of different sizes. These phantoms were made from molds of mannequins used for store display, of approximate heights 30", 40" and 50", representing children of ages 1-2, 4-5 and 8-10 yr, respectively. The sites chosen for irradiation were (1) the whole brain, (2) the chest, (3) the kidney bed, (4) the whole abdomen and (5) the spinal column. These sites are normally treated in such pediatric malignancies as medulloblastoma, neuroblastoma and Wilms' tumor. Some of the doses measured are less than 10 rad for an entire treatment regimen, and would therefore be categorized as low-level doses. Where radiation was the only mode of treatment for long-term survivors of such malignancies, especially those treated 20-30 yr ago with orthovoltage radiation, useful data may be extracted for contributing to our knowledge about the long-term effects of low levels of radiation.

  3. Background radiation dose of dumpsites in Ota and Environs

    NASA Astrophysics Data System (ADS)

    Usikalu, M. R.; Ola, O. O.; Achuka, J. A.; Babarimisa, I. O.; Ayara, W. A.

    2017-05-01

    In-situ measurement of background radiation dose from selected dumpsites in Ota and its environs was done using Radialert Nuclear Radiation Monitor (Digilert 200). Ten measurements were taken from each dumpsite. The measured background radiation range between 0.015 mRhr-1 for AOD and 0.028 mRhr-1 for SUS dumpsites. The calculated annual equivalent doses vary between 1.31 mSvyr-1 for AOD and 2.28 mSv/yr for SUS dumpsites. The air absorbed dose calculated ranged from 150 nGyhr-1 to 280 nGy/hr for AOD and SUS dumpsites respectively with an average value of 217 nGyhr-1 for all the locations. All the estimated parameters were higher than permissible limit set for background radiation for the general public. Conclusively, the associated challenge and radiation burden posed by the wastes on the studied locations and scavengers is high. Therefore, there is need by the regulatory authorities to look into the way and how waste can be properly managed so as to alleviate the effects on the populace leaving and working in the dumpsites vicinity.

  4. Is There a Dose-Response Relationship for Heart Disease With Low-Dose Radiation Therapy?

    SciTech Connect

    Chung, Eugene; Corbett, James R.; Moran, Jean M.; Griffith, Kent A.; Marsh, Robin B.; Feng, Mary; Jagsi, Reshma; Kessler, Marc L.; Ficaro, Edward C.; Pierce, Lori J.

    2013-03-15

    Purpose: To quantify cardiac radiation therapy (RT) exposure using sensitive measures of cardiac dysfunction; and to correlate dysfunction with heart doses, in the setting of adjuvant RT for left-sided breast cancer. Methods and Materials: On a randomized trial, 32 women with node-positive left-sided breast cancer underwent pre-RT stress single photon emission computed tomography (SPECT-CT) myocardial perfusion scans. Patients received RT to the breast/chest wall and regional lymph nodes to doses of 50 to 52.2 Gy. Repeat SPECT-CT scans were performed 1 year after RT. Perfusion defects (PD), summed stress defects scores (SSS), and ejection fractions (EF) were evaluated. Doses to the heart and coronary arteries were quantified. Results: The mean difference in pre- and post-RT PD was −0.38% ± 3.20% (P=.68), with no clinically significant defects. To assess for subclinical effects, PD were also examined using a 1.5-SD below the normal mean threshold, with a mean difference of 2.53% ± 12.57% (P=.38). The mean differences in SSS and EF before and after RT were 0.78% ± 2.50% (P=.08) and 1.75% ± 7.29% (P=.39), respectively. The average heart Dmean and D95 were 2.82 Gy (range, 1.11-6.06 Gy) and 0.90 Gy (range, 0.13-2.17 Gy), respectively. The average Dmean and D95 to the left anterior descending artery were 7.22 Gy (range, 2.58-18.05 Gy) and 3.22 Gy (range, 1.23-6.86 Gy), respectively. No correlations were found between cardiac doses and changes in PD, SSS, and EF. Conclusions: Using sensitive measures of cardiac function, no clinically significant defects were found after RT, with the average heart Dmean <5 Gy. Although a dose response may exist for measures of cardiac dysfunction at higher doses, no correlation was found in the present study for low doses delivered to cardiac structures and perfusion, SSS, or EF.

  5. [Fetus radiation doses from nuclear medicine and radiology diagnostic procedures. Potential risks and radiation protection instructions].

    PubMed

    Markou, Pavlos

    2007-01-01

    Although in pregnancy it is strongly recommended to avoid diagnostic nuclear medicine and radiology procedures, in cases of clinical necessity or when pregnancy is not known to the physician, these diagnostic procedures are to be applied. In such cases, counseling based on accurate information and comprehensive discussion about the risks of radiation exposure to the fetus should follow. In this article, estimations of the absorbed radiation doses due to nuclear medicine and radiology diagnostic procedures during the pregnancy and their possible risk effects to the fetus are examined and then discussed. Stochastic and detrimental effects are evaluated with respect to other risk factors and related to the fetus absorbed radiation dose and to the post-conception age. The possible termination of a pregnancy, due to radiation exposure is discussed. Special radiation protection instructions are given for radiation exposures in cases of possible, confirmed or unknown pregnancies. It is concluded that nuclear medicine and radiology diagnostic procedures, if not repeated during the pregnancy, are rarely an indication for the termination of pregnancy, because the dose received by the fetus is expected to be less than 100 mSv, which indicates the threshold dose for having deterministic effects. Therefore, the risk for the fetus due to these diagnostic procedures is low. However, stochastic effects are still possible but will be minimized if the radiation absorbed dose to the fetus is kept as low as possible.

  6. Sensitivity to low-dose radiation in radiosensitive wasted mice

    SciTech Connect

    Paunesku, T.; Protic, M.; Woloschak, G. E.

    1999-11-12

    Mice homozygous for the autosomal recessive wasted mutation (wst/wst) have abnormalities in T-lymphocytes and in the anterior motor neuron cells of the spinal cord, leading to sensitivity to low doses of ionizing radiation, hind limb paralysis, and immunodeficiency. This defect results in a failure to gain weight by 20 days and death at 28 days of age. The wasted mutation (previously mapped to mouse chromosome 2) is shown to be a 3-bp deletion in a T-cell-specific (and perhaps motor-neuron-specific) regulatory region (promoter) of the proliferating cell nuclear antigen (PCNA) gene on mouse chromosome 2. A regulatory element is also shown to be important in PCNA expression in T-lymphocytes and motor neuron cells afflicted by the 3-bp deletion in the PCNA promoter. The model is as follows: Absence of PCNA expression in the thymuses (and motor neurons) of wasted mice causes cellular apoptosis; this absence of expression is mediated by a positive transactor that can bind to the wild-type but not the wasted mutant PCNA promoter; the bound protein induces late expression of PCNA in T-lymphocytes and prevents onset of radiation sensitivity in the cells.

  7. The annual effective dose from natural sources of ionising radiation in Canada.

    PubMed

    Grasty, R L; LaMarre, J R

    2004-01-01

    A review and analysis of published information combined with the results of recent gamma ray surveys were used to determine the annual effective dose to Canadians from natural sources of radiation. The dose due to external radiation was determined from ground gamma ray surveys carried out in the cities of Toronto, Ottawa, Montreal and Winnipeg and was calculated to be 219 microSv. A compilation of airborne gamma ray data from Canada and the United States shows that there are large variations in external radiation with the highest annual outdoor level of 1424 microSv being found in northern Canada. The annual effective inhalation dose of 926 microSv from 222Rn and 220Rn was calculated from approximately 14,000 measurements across Canada. This value includes a contribution of 128 microSv from 222Rn in the outdoor air together with 6 microSv from long-lived uranium and thorium series radionuclides in dust particles. Based on published information, the annual effective dose due to internal radioactivity is 306 microSv. A program developed by the Federal Aviation Administration was used to calculate a population-weighted annual effective dose from cosmic radiation of 318 microSv. The total population-weighted average annual effective dose to Canadians from all sources of natural background radiation was calculated to be 1769 microSv but varies significantly from city to city, largely due to differences in the inhalation dose from 222Rn.

  8. Mechanisms of action for an anti-radiation vaccine in reducing the biological impact of high dose and dose-rate, low-linear energy transfer radiation exposure.

    PubMed

    Maliev, V; Popov, D; Casey, R C; Jones, J A

    2007-01-01

    were irradiated with doses known to induce the development of cerebral (SRD-1), non-specific toxic effects (SRD-2), gastrointestinal (SRD-3) and hematological (bone marrow) (SRD-4) syndromes. Our results suggest that an anti-radiation vaccine can be developed for prophylactic use against radiation damage induced by acute exposure to significant doses of low Linear Energy Transfer (LET) radiation for humans, including nuclear power workers, commercial and military pilots, cosmonauts/astronauts, nuclear-powered engine vessel operators and possibly even the civilian population in the case of a nuclear terrorism event.

  9. High dose bystander effects in spatially fractionated radiation therapy

    PubMed Central

    Asur, Rajalakshmi; Butterworth, Karl T.; Penagaricano, Jose A.; Prise, Kevin M.; Griffin, Robert J.

    2014-01-01

    Traditional radiotherapy of bulky tumors has certain limitations. Spatially fractionated radiation therapy (GRID) and intensity modulated radiotherapy (IMRT) are examples of advanced modulated beam therapies that help in significant reductions in normal tissue damage. GRID refers to the delivery of a single high dose of radiation to a large treatment area that is divided into several smaller fields, while IMRT allows improved dose conformity to the tumor target compared to conventional three-dimensional conformal radiotherapy. In this review, we consider spatially fractionated radiotherapy approaches focusing on GRID and IMRT, and present complementary evidence from different studies which support the role of radiation induced signaling effects in the overall radiobiological rationale for these treatments. PMID:24246848

  10. Trans-Atlantic Comparison of CT Radiation Doses in the Era of Radiation Dose-Tracking Software.

    PubMed

    Parakh, Anushri; Euler, Andre; Szucs-Farkas, Zsolt; Schindera, Sebastian T

    2017-09-12

    The purpose of this study is to compare diagnostic reference levels from a local European CT dose registry, using radiation-tracking software from a large patient sample, with preexisting European and North American diagnostic reference levels. Data (n = 43,761 CT scans obtained over the course of 2 years) for the European local CT dose registry were obtained from eight CT scanners at six institutions. Means, medians, and interquartile ranges of volumetric CT dose index (CTDIvol), dose-length product (DLP), size-specific dose estimate, and effective dose values for CT examinations of the head, paranasal sinuses, thorax, pulmonary angiogram, abdomen-pelvis, renal-colic, thorax-abdomen-pelvis, and thoracoabdominal angiogram were obtained using radiation-tracking software. Metrics from this registry were compared with diagnostic reference levels from Canada and California (published in 2015), the American College of Radiology (ACR) dose index registry (2015), and national diagnostic reference levels from local CT dose registries in Switzerland (2010), the United Kingdom (2011), and Portugal (2015). Our local registry had a lower 75th percentile CTDIvol for all protocols than did the individual internationally sourced data. Compared with our study, the ACR dose index registry had higher 75th percentile CTDIvol values by 55% for head, 240% for thorax, 28% for abdomen-pelvis, 42% for thorax-abdomen-pelvis, 128% for pulmonary angiogram, 138% for renal-colic, and 58% for paranasal sinus studies. Our local registry had lower diagnostic reference level values than did existing European and North American diagnostic reference levels. Automated radiation-tracking software could be used to establish and update existing diagnostic reference levels because they are capable of analyzing large datasets meaningfully.

  11. Pediatric cardiac-gated CT angiography: assessment of radiation dose.

    PubMed

    Hollingsworth, Caroline L; Yoshizumi, Terry T; Frush, Donald P; Chan, Frandics P; Toncheva, Greta; Nguyen, Giao; Lowry, Carolyn R; Hurwitz, Lynne M

    2007-07-01

    The purpose of our study was to determine a dose range for cardiac-gated CT angiography (CTA) in children. ECG-gated cardiac CTA simulating scanning of the heart was performed on an anthropomorphic phantom of a 5-year-old child on a 16-MDCT scanner using variable parameters (small field of view; 16 x 0.625 mm configuration; 0.5-second gantry cycle time; 0.275 pitch; 120 kVp at 110, 220, and 330 mA; and 80 kVp at 385 mA). Metal oxide semiconductor field effect transistor (MOSFET) technology measured 20 organ doses. Effective dose calculated using the dose-length product (DLP) was compared with effective dose determined from measured absorbed organ doses. Highest organ doses included breast (3.5-12.6 cGy), lung (3.3-12.1 cGy), and bone marrow (1.7-7.6 cGy). The 80 kVp/385 mA examination produced lower radiation doses to all organs than the 120 kVp/220 mA examination. MOSFET effective doses (+/- SD) were as follows: 110 mA: 7.4 mSv (+/- 0.6 mSv), 220 mA: 17.2 mSv (+/- 0.3 mSv), 330 mA: 25.7 mSv (+/- 0.3 mSv), 80 kVp/385 mA: 10.6 mSv (+/- 0.2 mSv). DLP effective doses for diagnostic runs were as follows: 110 mA: 8.7 mSv, 220 mA: 19 mSv, 330 mA: 28 mSv, 80 kVp/385 mA: 12 mSv. DLP effective doses exceeded MOSFET effective doses by 9.7-17.2%. Radiation doses for a 5-year-old during cardiac-gated CTA vary greatly depending on parameters. Organ doses can be high; the effective dose may reach 28.4 mSv. Further work, including determination of size-appropriate mA and image quality, is important before routine use of this technique in children.

  12. Radiation environments and absorbed dose estimations on manned space missions

    NASA Technical Reports Server (NTRS)

    Curtis, S. B.; Atwell, W.; Beever, R.; Hardy, A.

    1986-01-01

    The dose and dose-equivalent estimates that astronauts might be expected to receive in space were assessed for the development of new radiation protection guidelines, considering several space mission scenarios. These scenarios included a 90-day LEO mission at 450 km altitude with orbital inclinations appropriate for NASA's Space Station (28.5, 57, and 90 deg), a 15-day sortie to GEO, and a 90-day lunar mission. All the missions contemplated would present space travelers with dose equivalents between 5 and 10 rem to the blood-forming organs, assuming no encounter with a large solar particle event; a large particle event could add considerable exposure for all scenarios except for the one at 28.5 orbital inclination. Adequate shielding must be included to guard against the radiation produced by such events.

  13. Impact of dose calculation algorithm on radiation therapy

    PubMed Central

    Chen, Wen-Zhou; Xiao, Ying; Li, Jun

    2014-01-01

    The quality of radiation therapy depends on the ability to maximize the tumor control probability while minimize the normal tissue complication probability. Both of these two quantities are directly related to the accuracy of dose distributions calculated by treatment planning systems. The commonly used dose calculation algorithms in the treatment planning systems are reviewed in this work. The accuracy comparisons among these algorithms are illustrated by summarizing the highly cited research papers on this topic. Further, the correlation between the algorithms and tumor control probability/normal tissue complication probability values are manifested by several recent studies from different groups. All the cases demonstrate that dose calculation algorithms play a vital role in radiation therapy. PMID:25431642

  14. Dose and volume impact on radiation-induced xerostomia.

    PubMed

    Marmiroli, Luca; Salvi, Giovanna; Caiazza, Adolfo; Di Rienzo, Luigi; Massaccesi, Mariangela; Murino, Paola; Macchia, Gabriella

    2005-01-01

    Radiation-induced xerostomia consists in the chronic dryness of the mouth caused by parotid gland irradiation. Parotid glands produce approximately 60% of saliva while the rest is secreted by submandibular and accessory salivary glands. Methods of measuring the salivary output are essentially represented by 99mTc-pertechnate scintigraphy or simpler albeit less accurate methods in stimulated or unstimulated saliva. There are subjective and objective criteria of classification and grading of the secretion of saliva. Radiation-induced xerostomia, namely the residual salivary gland function is evidently associated with the mean dose absorbed. The salivary output tends to decrease after the end of radiotherapy. The partial dose-volume is substantially correlated with the mean dose to the whole gland. As for ipsilateral irradiation for head and neck cancer, conformal RT or IMRT allow to spare the contralateral parotid gland without increasing the risk of contralateral nodal recurrences. The monitoring system of late toxicity used by the authors is presented.

  15. Dose-response effect of human equivalent radiation in the murine mandible: A radiomorphometric assessment

    PubMed Central

    Monson, Laura A.; Jing, X. Lin; Donneys, Alexis; Farberg, Aaron S.; Buchman, Steven R.

    2016-01-01

    Background Despite widespread use of adjuvant irradiation for head and neck cancer, the extent of damage to the underlying bone is not fully understood, but is associated with pathologic fractures, nonunion, and osteoradionecrosis. The authors’ laboratory previously demonstrated that radiation significantly impedes new bone formation in the murine mandible. We hypothesize that the detrimental effects of human equivalent radiation on the murine mandible results in a dose-dependent degradation in traditional micro-CT metrics. Methods Fifteen male Sprague-Dawley rats were randomized into three radiation dosage groups: low (5.91 Gy), middle (7 Gy), and high (8.89 Gy), delivered in five daily fractions. These dosages approximated 75, 100 and 150 percent, respectively, of the biologically equivalent dose that the human mandible receives during radiation treatment. Hemimandibles were harvested 56 days after radiation and scanned using microCT. Bone mineral density, tissue mineral density, and bone volume fraction were measured along with microdensitometry measurements. Results Animals demonstrated dose dependent side effects of mucositis, alopecia, weight loss and mandibular atrophy with increasing radiation. Traditional microCT parameters were not sensitive enough to demonstrate statistically significant differences between the radiated groups; however microdensitometry analysis showed clear differences between radiated groups and statistically significant changes between radiated and non-radiated groups. Conclusions The authors report dose-dependent and clinically significant side effects of fractionated human equivalent radiation to the murine mandible. The authors further report the limited capacity of traditional micro-CT metrics to adequately capture key changes in bone composition and present microdensitometric histogram analysis in order to demonstrate significant radiation induced changes in mineralization patterns. PMID:24036733

  16. Results from the Martian Radiation Environment Experiment

    NASA Astrophysics Data System (ADS)

    Zeitlin, C.; Cleghorn, T.; Cucinotta, F.; Saganti, P.; Andersen, V.; Lee, K.; Pinsky, L.; Atwell, W.; Turner, R.

    2003-04-01

    One of the three science instruments aboard the 2001 Mars Odyssey spacecraft is the Martian Radiation Environment Experiment, MARIE. The experiment consists of a stack of silicon detectors, augmented by a Cerenkov detector. MARIE is designed to measure a portion of the particle spectrum of the Galactic Cosmic Rays (GCR), as well as the high fluxes of low-energy protons (energies less than about 100 MeV) that are intermittently produced by active regions on the sun in Solar Particle Events (SPE). MARIE is providing the first detailed information about the radiation environment near Mars. The silicon detectors record the ionization energy loss of incident particles. For the particle energies measured by MARIE, the energy depositions in silicon are, to a good approximation, proportional to radiation dose in tissue. Thus pulse-height data from the silicon detectors provide a reliable measurement of the dose. Preliminary comparisons with the HZETRN model of the GCR show good agreement during solar quiet times, although more work is needed to adjust the model for some of the limitations of the detector. Also, several solar particle events of considerable interest have been observed. Detailed comparisons of these events as seen at Mars and as seen by near-Earth detectors such as GOES-8 provide information about the CME-driven shockwaves that accelerate the particles.

  17. Micro RNA responses to chronic or acute exposures to low dose ionizing radiation

    PubMed Central

    Chaudhry, M. Ahmad; Omaruddin, Romaica A.; Kreger, Bridget; de Toledo, Sonia M.; Azzam, Edouard I.

    2014-01-01

    Human health risks of exposure to low dose ionizing radiation remain ambiguous and are the subject of intense debate. A wide variety of biological effects are induced after cellular exposure to ionizing radiation, but the underlying molecular mechanism(s) remain to be completely understood. We hypothesized that low dose c-radiation-induced effects are controlled by the modulation of micro RNA (miRNA) that participate in the control of gene expression at the posttranscriptional level and are involved in many cellular processes. We monitored the expression of several miRNA in human cells exposed to acute or chronic low doses of 10 cGy or a moderate dose of 400 cGy of 137Cs γ-rays. Dose, dose rate and time dependent differences in the relative expression of several miRNA were investigated. The expression patterns of many miRNA differed after exposure to either chronic or acute 10 cGy. The expression of miRNA let-7e, a negative regulator of RAS oncogene, and the c-MYC miRNA cluster were upregulated after 10 cGy chronic dose but were downregulated after 3 h of acute 10 cGy. The miR-21 was upregulated in chronic or acute low dose and moderate dose treated cells and its target genes hPDCD4, hPTEN, hSPRY2, and hTPM1 were found to be downregulated. These findings provide evidence that low dose and dose rate c-irradiation dictate the modulation of miRNA, which can result in a differential cellular response than occurs at high doses. This information will contribute to understanding the risks to human health after exposure to low dose radiation. PMID:22367372

  18. The Radiation Dose Determination of the Pulsed X-ray Source

    NASA Astrophysics Data System (ADS)

    Miloichikova, I.; Stuchebrov, S.; Zhaksybayeva, G.; Wagner, A.

    2014-10-01

    In this paper the radiation dose measurement technique of the pulsed X-ray source RAP-160-5 is described. The dose rate measurement results from the pulsed X-ray beams at the different distance between the pulsed X-ray source focus and the detector obtained with the help of the thermoluminescent detectors DTL-02, the universal dosimeter UNIDOS E equipped with the plane-parallel ionization chamber type 23342, the dosimeter-radiometer DKS-96 and the radiation dosimeter AT 1123 are demonstrated. The recommendations for the dosimetry measurements of the pulsed X-ray generator RAP-160-5 under different radiation conditions are proposed.

  19. Effect of different prosthetic materials on radiation dose distribution in an orbital defect: a clinical report.

    PubMed

    Ozçelik, Tuncer Burak; Onal, Cem; Efe, Esma; Yilmaz, Burak

    2012-04-01

    It is challenging to treat and irradiate empty cavities with external-beam radiation therapy (EBRT) because body contour irregularities can result in dose heterogeneities. The use of compensator materials to fill the empty cavities can provide a more homogeneous radiation dose distribution. The purposes of this clinical report are to describe the use of 3 different materials (elastomeric material, water-filled balloon, and acrylic resin) in an orbital defect and compare the dosimetric parameters and photon-electron dose distribution during EBRT. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  20. Chernobyl doses. Volume 1. Analysis of forest canopy radiation response from multispectral imagery and the relationship to doses. Technical report, 29 July 1987-30 September 1993

    SciTech Connect

    McClennan, G.E.; Anno, G.H.; Whicker, F.W.

    1994-09-01

    This volume of the report Chernobyl Doses presents details of a new, quantitative method for remotely sensing ionizing radiation dose to vegetation. Analysis of Landsat imagery of the area within a few kilometers of the Chernobyl nuclear reactor station provides maps of radiation dose to pine forest canopy resulting from the accident of April 26, 1986. Detection of the first date of significant, persistent deviation from normal of the spectral reflectance signature of pine foliage produces contours of radiation dose in the 20 to 80 Gy range extending up to 4 km from the site of the reactor explosion. The effective duration of exposure for the pine foliage is about 3 weeks. For this exposure time, the LD50 of Pinus sylvestris (Scotch pine) is about 23 Gy. The practical lower dose limit for the remote detection of radiation dose to pine foliage with the Landsat Thematic Mapper is about 5 Gy or 1/4 of the LD50.

  1. The Effect of High-Dose Ionizing Radiation on the Astrobiological Model Lichen Circinaria gyrosa.

    PubMed

    de la Torre, Rosa; Miller, Ana Zélia; Cubero, Beatriz; Martín-Cerezo, M Luisa; Raguse, Marina; Meeßen, Joachim

    2017-02-01

    The lichen Circinaria gyrosa is an astrobiological model defined by its high capacity of resistance to space conditions and to a simulated martian environment. Therefore, it became part of the currently operated BIOMEX experiment on board the International Space Station and the recent STARLIFE campaign to study the effects of four types of space-relevant ionizing radiation. The samples were irradiated with helium and iron ions at doses up to 2 kGy, with X-rays at doses up to 5 kGy and with γ rays at doses from 6 to 113 kGy. Results on C. gyrosa's resistance to simulated space ionizing radiation and its post-irradiation viability were obtained by (i) chlorophyll a fluorescence of photosystem II (PSII), (ii) epifluorescence microscopy, (iii) confocal laser scanning microscopy (CLSM), and (iv) field emission scanning electron microscopy (FESEM). Results of photosynthetic activity and epifluorescence show no significant changes up to a dose of 1 kGy (helium ions), 2 kGy (iron ions), 5 kGy (X-rays)-the maximum doses applied for those radiation qualities-as well as a dose of 6 kGy of γ irradiation, which was the lowest dose applied for this low linear energy transfer (LET) radiation. Significant damage in a dose-related manner was observed only at much higher doses of γ irradiation (up to 113 kGy). These data corroborate the findings of the parallel STARLIFE studies on the effects of ionizing radiation on the lichen Circinaria gyrosa, its isolated photobiont, and the lichen Xanthoria elegans. Key Words: Simulated space ionizing radiation-Gamma rays-Extremotolerance-Lichens-Circinaria gyrosa-Photosynthetic activity. Astrobiology 17, 145-153.

  2. Increasing Use of Dose-Escalated External Beam Radiation Therapy for Men With Nonmetastatic Prostate Cancer

    SciTech Connect

    Swisher-McClure, Samuel; Mitra, Nandita; Woo, Kaitlin; Smaldone, Marc; Uzzo, Robert; Bekelman, Justin E.

    2014-05-01

    Purpose: To examine recent practice patterns, using a large national cancer registry, to understand the extent to which dose-escalated external beam radiation therapy (EBRT) has been incorporated into routine clinical practice for men with prostate cancer. Methods and Materials: We conducted a retrospective observational cohort study using the National Cancer Data Base, a nationwide oncology outcomes database in the United States. We identified 98,755 men diagnosed with nonmetastatic prostate cancer between 2006 and 2011 who received definitive EBRT and classified patients into National Comprehensive Cancer Network (NCCN) risk groups. We defined dose-escalated EBRT as total prescribed dose of ≥75.6 Gy. Using multivariable logistic regression, we examined the association of patient, clinical, and demographic characteristics with the use of dose-escalated EBRT. Results: Overall, 81.6% of men received dose-escalated EBRT during the study period. The use of dose-escalated EBRT did not vary substantially by NCCN risk group. Use of dose-escalated EBRT increased from 70.7% of patients receiving treatment in 2006 to 89.8% of patients receiving treatment in 2011. On multivariable analysis, year of diagnosis and use of intensity modulated radiation therapy were significantly associated with receipt of dose-escalated EBRT. Conclusions: Our study results indicate that dose-escalated EBRT has been widely adopted by radiation oncologists treating prostate cancer in the United States. The proportion of patients receiving dose-escalated EBRT increased nearly 20% between 2006 and 2011. We observed high utilization rates of dose-escalated EBRT within all disease risk groups. Adoption of intensity modulated radiation therapy was strongly associated with use of dose-escalated treatment.

  3. Dose Response for Chromosome Aberrations in Human Lymphocytes and Fibroblasts After Exposure to Very Low Dose of High Let Radiation

    NASA Technical Reports Server (NTRS)

    Hada, M.; George, K.; Chappell, L.; Cucinotta, F. A.

    2011-01-01

    The relationship between biological effects and low doses of absorbed radiation is still uncertain, especially for high LET radiation exposure. Estimates of risks from low-dose and low-dose-rates are often extrapolated using data from Japanese atomic bomb survivor with either linear or linear quadratic models of fit. In this study, chromosome aberrations were measured in human peripheral blood lymphocytes and normal skin fibroblasts cells after exposure to very low dose (0.01 - 0.20 Gy) of 170 MeV/u Si-28 ions or 600 MeV/u Fe-56 ions, including doses where on average less than one direct ion traversal per cell nucleus occurs. Chromosomes were analyzed using the whole-chromosome fluorescence in situ hybridization (FISH) technique during the first cell division after irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving >2 breaks in 2 or more chromosomes). The responses for doses above 0.1 Gy (more than one ion traverses a cell) showed linear dose responses. However, for doses less than 0.1 Gy, both Si-28 ions and Fe-56 ions showed a dose independent response above background chromosome aberrations frequencies. Possible explanations for our results are non-targeted effects due to aberrant cell signaling [1], or delta-ray dose fluctuations [2] where a fraction of cells receive significant delta-ray doses due to the contributions of multiple ion tracks that do not directly traverse cell nuclei where chromosome aberrations are scored.

  4. Radiation dose-reduction strategies for neuroradiology CT protocols.

    PubMed

    Smith, A B; Dillon, W P; Gould, R; Wintermark, M

    2007-10-01

    Within the past 2 decades, the number of CT examinations performed has increased almost 10-fold. This is in large part due to advances in multidetector-row CT technology, which now allows faster image acquisition and improved isotropic imaging. The increased use, along with multidetector technique, has led to a significantly increased radiation dose to the patient from CT studies. This places increased responsibility on the radiologist to ensure that CT examinations are indicated and that the "as low as reasonably achievable" concept is adhered to. Neuroradiologists are familiar with factors that affect patient dose such as pitch, milliamperes, kilovolt peak (kVp), collimation, but with increasing attention being given to dose reduction, they are looking for additional ways to further reduce the radiation associated with their CT protocols. In response to increasing concern, CT manufacturers have developed dose-reduction tools, such as dose modulation, in which the tube current is adjusted along with the CT acquisition, according to patient's attenuation. This review will describe the available techniques for reducing dose associated with neuroradiologic CT imaging protocols.

  5. Changes in biomarkers from space radiation may reflect dose not risk

    NASA Astrophysics Data System (ADS)

    Brooks, Antone L.; Lei, Xingye C.; Rithidech, Kanokporn

    This presentation evaluates differences between radiation biomarkers of dose and risk and demonstrates the consequential problems associated with using biomarkers to do risk calculations following radiation exposures to the complex radiation environment found in deep space. Dose is a physical quantity, while risk is a biological quantity. Dose does not predict risk. This manuscript discusses species sensitivity factors, tissue weighting factors, and radiation quality factors derived from relative biological effectiveness (RBE). These factors are used to modify dose to make it a better predictor of risk. At low doses, where it is not possible to measure changes in risk, biomarkers have been used incorrectly as an intermediate step in predicting risk. Examples of biomarkers that do not predict risk are reviewed. Species sensitivity factors were evaluated using the Syrian hamster and the Wistar rat. Although the frequency of chromosome damage is very similar in these two species, the Wistar rat is very sensitive to radiation-induced lung cancer while the Syrian hamster is very resistant. To illustrate problems involved in using tissue weighting factors, rat trachea and deep lung tissues were compared. The similar level of chromosome damage observed in these two tissues would predict that the risk for cancer induction would be the same. However, even though large numbers of deep lung tumors result from inhaled radon, under the same exposure conditions there has never been a tracheal tumor observed. Finally, the Relative Biological Effectiveness (RBE) used to generate "quality factors" that convert exposure and dose from different types of radiation to a single measure of risk, is discussed. Important risk comparisons are done at very low doses, where the response to the reference radiation has been shown to either increase or decrease as a function of dose. Thus, the RBE and the subsequent risk predicted is more dependent on the background response of the endpoint and

  6. Influence of Flat-Panel Fluoroscopic Equipment Variables on Cardiac Radiation Doses

    SciTech Connect

    Nickoloff, Edward L. Lu Zhengfeng; Dutta, Ajoy; So, James; Balter, Stephen; Moses, Jeffrey

    2007-04-15

    Purpose. To assess the influence of physician-selectable equipment variables on the potential radiation dose reductions during cardiac catheterization examinations using modern imaging equipment. Materials. A modern bi-plane angiography unit with flat-panel image receptors was used. Patients were simulated with 15-30 cm of acrylic plastic. The variables studied were: patient thickness, fluoroscopy pulse rates, record mode frame rates, image receptor field-of-view (FoV), automatic dose control (ADC) mode, SID/SSD geometry setting, automatic collimation, automatic positioning, and others. Results. Patient radiation doses double for every additional 3.5-4.5 cm of soft tissue. The dose is directly related to the imaging frame rate; a decrease from 30 pps to 15 pps reduces the dose by about 50%. The dose is related to [(FoV){sup -N}] where 2.0 < N < 3.0. Suboptimal positioning of the patient can nearly double the dose. The ADC system provides three selections that can vary the radiation level by 50%. For pediatric studies (2-5 years old), the selection of equipment variables can result in entrance radiation doses that range between 6 and 60 cGy for diagnostic cases and between 15 and 140 cGy for interventional cases. For adult studies, the equipment variables can produce entrance radiation doses that range between 13 and 130 cGy for diagnostic cases and between 30 and 400 cGy for interventional cases. Conclusions. Overall dose reductions of 70-90% can be achieved with pediatric patients and about 90% with adult patients solely through optimal selection of equipment variables.

  7. Low-dose ionising radiation and cardiovascular diseases--Strategies for molecular epidemiological studies in Europe.

    PubMed

    Kreuzer, Michaela; Auvinen, Anssi; Cardis, Elisabeth; Hall, Janet; Jourdain, Jean-Rene; Laurier, Dominique; Little, Mark P; Peters, Annette; Raj, Ken; Russell, Nicola S; Tapio, Soile; Zhang, Wei; Gomolka, Maria

    2015-01-01

    It is well established that high-dose ionising radiation causes cardiovascular diseases. In contrast, the evidence for a causal relationship between long-term risk of cardiovascular diseases after moderate doses (0.5-5 Gy) is suggestive and weak after low doses (<0.5 Gy). However, evidence is emerging that doses under 0.5 Gy may also increase long-term risk of cardiovascular disease. This would have major implications for radiation protection with respect to medical use of radiation for diagnostic purposes and occupational or environmental radiation exposure. Therefore, it is of great importance to gain information about the presence and possible magnitude of radiation-related cardiovascular disease risk at doses of less than 0.5 Gy. The biological mechanisms implicated in any such effects are unclear and results from epidemiological studies are inconsistent. Molecular epidemiological studies can improve the understanding of the pathogenesis and the risk estimation of radiation-induced circulatory disease at low doses. Within the European DoReMi (Low Dose Research towards Multidisciplinary Integration) project, strategies to conduct molecular epidemiological studies in this field have been developed and evaluated. Key potentially useful European cohorts are the Mayak workers, other nuclear workers, uranium miners, Chernobyl liquidators, the Techa river residents and several diagnostic or low-dose radiotherapy patient cohorts. Criteria for informative studies are given and biomarkers to be investigated suggested. A close collaboration between epidemiology, biology and dosimetry is recommended, not only among experts in the radiation field, but also those in cardiovascular diseases.

  8. Recent Radiation Test Results for Power MOSFETs

    NASA Technical Reports Server (NTRS)

    Lauenstein, Jean-Marie; Topper, Alyson D.; Casey, Megan C.; Wilcox, Edward P.; Phan, Anthony M.; Kim, Hak S.; LaBel, Kenneth A.

    2013-01-01

    Single-event effect (SEE) and total ionizing dose (TID) test results are presented for various hardened and commercial power metal-oxide-semiconductor field effect transistors (MOSFETs), including vertical planar, trench, superjunction, and lateral process designs.

  9. Radiation Leukemogenesis: Applying Basic Science of Epidemiological Estimates of Low Dose Risks and Dose-Rate Effects

    SciTech Connect

    Hoel, D. G.

    1998-11-01

    The next stage of work has been to examine more closely the A-bomb leukemia data which provides the underpinnings of the risk estimation of CML in the above mentioned manuscript. The paper by Hoel and Li (Health Physics 75:241-50) shows how the linear-quadratic model has basic non-linearities at the low dose region for the leukemias including CML. Pierce et. al., (Radiation Research 123:275-84) have developed distributions for the uncertainty in the estimated exposures of the A-bomb cohort. Kellerer, et. al., (Radiation and Environmental Biophysics 36:73-83) has further considered possible errors in the estimated neutron values and with changing RBE values with dose and has hypothesized that the tumor response due to gamma may not be linear. We have incorporated his neutron model and have constricted new A-bomb doses based on his model adjustments. The Hoel and Li dose response analysis has also been applied using the Kellerer neutron dose adjustments for the leukemias. Finally, both Pierce's dose uncertainties and Kellerer neutron adjustments are combined as well as the varying RBE with dose as suggested by Rossi and Zaider and used for leukemia dose-response analysis. First the results of Hoel and Li showing a significantly improved fit of the linear-quadratic dose response by the inclusion of a threshold (i.e. low-dose nonlinearity) persisted. This work has been complete for both solid tumor as well as leukemia for both mortality as well as incidence data. The results are given in the manuscript described below which has been submitted to Health Physics.

  10. Key clinical beam parameters for nanoparticle-mediated radiation dose amplification

    PubMed Central

    Detappe, Alexandre; Kunjachan, Sijumon; Drané, Pascal; Kotb, Shady; Myronakis, Marios; Biancur, Douglas E.; Ireland, Thomas; Wagar, Matthew; Lux, Francois; Tillement, Olivier; Berbeco, Ross

    2016-01-01

    As nanoparticle solutions move towards human clinical trials in radiation therapy, the influence of key clinical beam parameters on therapeutic efficacy must be considered. In this study, we have investigated the clinical radiation therapy delivery variables that may significantly affect nanoparticle-mediated radiation dose amplification. We found a benefit for situations which increased the proportion of low energy photons in the incident beam. Most notably, “unflattened” photon beams from a clinical linear accelerator results in improved outcomes relative to conventional “flat” beams. This is measured by significant DNA damage, tumor growth suppression, and overall improvement in survival in a pancreatic tumor model. These results, obtained in a clinical setting, clearly demonstrate the influence and importance of radiation therapy parameters that will impact clinical radiation dose amplification with nanoparticles. PMID:27658637

  11. Cumulative effects of repeated subthreshold doses of ultraviolet radiation

    SciTech Connect

    Parrish, J.A.; Zaynoun, S.; Anderson, R.R.

    1981-05-01

    For fair Caucasian skin, the minimal delayed erythema dose (MED) 24 hr after exposure to broadband UVA is about 1200 times greater than the MED of broadband UVB, for both single and multiple daily exposures. Repeated daily exposure to doses less than MED results in cumulative effects manifest by gradual lowering of the daily dose threshold for delayed erythema and pigmentation induced by UVA or UVB. At threshold doses, UVB is more erythemogenic than melanogenic; the opposite is true for UVA. Repeated daily UVA exposure greatly enhances melanogenesis such that markedly suberythemogenic exposure doses of UVA result in true melanogenesis.

  12. Radiation Resistance Study of Semi-Insulating GaAs-Based Radiation Detectors to Extremely High Gamma Doses

    NASA Astrophysics Data System (ADS)

    Ly Anh, T.; Perd'ochová, A.; Nečas, V.; Pavlicová, V.

    2006-01-01

    In our previous paper [V. Nečas et al.: Nucl. Inst. and Meth. A 458 (2001) 348-351] we reported on the study on radiation stability of semi-insulating (SI) LEG GaAs detectors to doses of photons from 60Co up to 19.2 kGy. Later we presented a study, which covered radiation hardness to the same doses on the base of detector material itself, where strong dependence has been proved [T. Ly Anh et al., Proceedings of the XII th International Conference on Semiconducting and Insulating Materials (SIMC-XII-2002). Smolenice Castle, Slovakia (2002) 292-295 (0-7803-7418-5)]. In this paper we present both the key electrical and detection characteristics of SI GaAs radiation detectors prepared using substrates from four various supplies and two different types of contacts, which were exposed to several gamma doses from 60Co up to the integral dose of about 1 MGy. The obtained results show that SI LEG GaAs detectors provide good spectroscopic performances and even their slight improvement after low to middle gamma irradiation doses (3 -10 kGy) was observed. Further dose exposure caused the degradation of detection properties with an extreme and following improvement depending on detector material properties. SI GaAs detector still retains its working capabilities even after very high doses applied, up to 1 MGy.

  13. Radiosensitization of Human Cervical Cancer Cells by Inhibiting Ribonucleotide Reductase: Enhanced Radiation Response at Low-Dose Rates

    SciTech Connect

    Kunos, Charles A.; Colussi, Valdir C.; Pink, John; Radivoyevitch, Tomas; Oleinick, Nancy L.

    2011-07-15

    Purpose: To test whether pharmacologic inhibition of ribonucleotide reductase (RNR) by 3-aminopyridine-2-carboxaldehyde thiosemicarbazone (3-AP, NSC no. 663249) enhances radiation sensitivity during low-dose-rate ionizing radiation provided by a novel purpose-built iridium-192 cell irradiator. Methods and Materials: The cells were exposed to low-dose-rate radiation (11, 23, 37, 67 cGy/h) using a custom-fabricated cell irradiator or to high-dose-rate radiation (330 cGy/min) using a conventional cell irradiator. The radiation sensitivity of human cervical (CaSki, C33-a) cancer cells with or without RNR inhibition by 3-AP was evaluated using a clonogenic survival and an RNR activity assay. Alteration in the cell cycle distribution was monitored using flow cytometry. Results: Increasing radiation sensitivity of both CaSki and C33-a cells was observed with the incremental increase in radiation dose rates. 3-AP treatment led to enhanced radiation sensitivity in both cell lines, eliminating differences in cell cytotoxicity from the radiation dose rate. RNR blockade by 3-AP during low-dose-rate irradiation was associated with low RNR activity and extended G{sub 1}-phase cell cycle arrest. Conclusions: We conclude that RNR inhibition by 3-AP impedes DNA damage repair mechanisms that rely on deoxyribonucleotide production and thereby increases radiation sensitivity of human cervical cancers to low-dose-rate radiation.

  14. Radiation environments and absorbed dose estimations on manned space missions.

    PubMed

    Curtis, S B; Atwell, W; Beever, R; Hardy, A

    1986-01-01

    In order to make an assessment of radiation risk during manned missions in space, it is necessary first to have as accurate an estimation as possible of the radiation environment within the spacecraft to which the astronauts will be exposed. Then, with this knowledge and the inclusion of body self-shielding, estimations can be made of absorbed doses for various body organs (skin, eye, blood-forming organs, etc.). A review is presented of our present knowledge of the radiation environments and absorbed doses expected for several space mission scenarios selected for our development of the new radiation protection guidelines. The scenarios selected are a 90-day mission at an altitude (450 km) and orbital inclinations (28.5 degrees, 57 degrees and 90 degrees) appropriate for NASA's Space Station, a 15-day sortie to geosynchronous orbit and a 90-day lunar mission. All scenarios chosen yielded dose equivalents between five and ten rem to the blood forming organs if no large solar particle event were encountered. Such particle events could add considerable exposure particularly to the skin and eye for all scenarios except the one at 28.5 degrees orbital inclination.

  15. Hormetic Response to Low-Dose Radiation: Focus on the Immune System and Its Clinical Implications.

    PubMed

    Cui, Jiuwei; Yang, Guozi; Pan, Zhenyu; Zhao, Yuguang; Liang, Xinyue; Li, Wei; Cai, Lu

    2017-01-27

    The interrelationship between ionizing radiation and the immune system is complex, multifactorial, and dependent on radiation dose/quality and immune cell type. High-dose radiation usually results in immune suppression. On the contrary, low-dose radiation (LDR) modulates a variety of immune responses that have exhibited the properties of immune hormesis. Although the underlying molecular mechanism is not fully understood yet, LDR has been used clinically for the treatment of autoimmune diseases and malignant tumors. These advancements in preclinical and clinical studies suggest that LDR-mediated immune modulation is a well-orchestrated phenomenon with clinical potential. We summarize recent developments in the understanding of LDR-mediated immune modulation, with an emphasis on its potential clinical applications.

  16. Hormetic Response to Low-Dose Radiation: Focus on the Immune System and Its Clinical Implications

    PubMed Central

    Cui, Jiuwei; Yang, Guozi; Pan, Zhenyu; Zhao, Yuguang; Liang, Xinyue; Li, Wei; Cai, Lu

    2017-01-01

    The interrelationship between ionizing radiation and the immune system is complex, multifactorial, and dependent on radiation dose/quality and immune cell type. High-dose radiation usually results in immune suppression. On the contrary, low-dose radiation (LDR) modulates a variety of immune responses that have exhibited the properties of immune hormesis. Although the underlying molecular mechanism is not fully understood yet, LDR has been used clinically for the treatment of autoimmune diseases and malignant tumors. These advancements in preclinical and clinical studies suggest that LDR-mediated immune modulation is a well-orchestrated phenomenon with clinical potential. We summarize recent developments in the understanding of LDR-mediated immune modulation, with an emphasis on its potential clinical applications. PMID:28134809

  17. Galactic cosmic ray-induced radiation dose on terrestrial exoplanets.

    PubMed

    Atri, Dimitra; Hariharan, B; Grießmeier, Jean-Mathias

    2013-10-01

    This past decade has seen tremendous advancements in the study of extrasolar planets. Observations are now made with increasing sophistication from both ground- and space-based instruments, and exoplanets are characterized with increasing precision. There is a class of particularly interesting exoplanets that reside in the habitable zone, which is defined as the area around a star where the planet is capable of supporting liquid water on its surface. Planetary systems around M dwarfs are considered to be prime candidates to search for life beyond the Solar System. Such planets are likely to be tidally locked and have close-in habitable zones. Theoretical calculations also suggest that close-in exoplanets are more likely to have weaker planetary magnetic fields, especially in the case of super-Earths. Such exoplanets are subjected to a high flux of galactic cosmic rays (GCRs) due to their weak magnetic moments. GCRs are energetic particles of astrophysical origin that strike the planetary atmosphere and produce secondary particles, including muons, which are highly penetrating. Some of these particles reach the planetary surface and contribute to the radiation dose. Along with the magnetic field, another factor governing the radiation dose is the depth of the planetary atmosphere. The higher the depth of the planetary atmosphere, the lower the flux of secondary particles will be on the surface. If the secondary particles are energetic enough, and their flux is sufficiently high, the radiation from muons can also impact the subsurface regions, such as in the case of Mars. If the radiation dose is too high, the chances of sustaining a long-term biosphere on the planet are very low. We have examined the dependence of the GCR-induced radiation dose on the strength of the planetary magnetic field and its atmospheric depth, and found that the latter is the decisive factor for the protection of a planetary biosphere.

  18. Missing dose from mortality studies of radiation effects among workers at Oak Ridge National Laboratory.

    PubMed

    Kerr, G D

    1994-02-01

    Missing dose is a problem that has not been adequately addressed in the mortality studies of radiation effects among workers at Oak Ridge National Laboratory. The missing dose is a result of recording a zero for below-detectable doses, especially for frequent (weekly) film badge readings. To make the thorough dosimetry assessment needed in the current Oak Ridge National Laboratory worker studies, it will probably be necessary to consider all data at hand including personnel dose records, daily pocket meter readings used to supplement weekly and quarterly readings from other dosimeters, and monitoring results from both building surveys and fixed stations. The fixed-station data should be extremely useful in developing a better understanding of the unusual temporal variation of the external radiation doses to Oak Ridge National Laboratory workers during the high exposure-rate periods of the 1950s and early 1960s.

  19. Analysis of radiation doses from operation of postulated commercial spent fuel transportation systems: Main report

    SciTech Connect

    Schneider, K.J.; Hostick, C.J.; Ross, W.A.; Peterson, R.W.; Smith, R.I.; Stiles, D.L.; Daling, P.M.; Weakley, S.A.; Grinde, R.B.; Young, J.R.

    1987-11-01

    This report contains a system study of estimated radiation doses to the public and workers resulting from the transport of spent fuel from commercial nuclear power reactors to a geologic repository. The report contains a detailed breakdown of activities and a description of time/distance/dose-rate estimates for each activity within the system. Collective doses are estimated for each of the major activities at the reactor site, in transit, and at the repository receiving facility. Annual individual doses to the maximally exposed individuals or groups of individuals are also estimated. A total of 17 alternatives and subalternatives to the postulated reference transportation system are identified, conceptualized, and their dose-reduction potentials and costs estimated. Resulting ratios of ..delta..cost/..delta..collective system dose for each alternative relative to the postulated reference transportation system are given. Most of the alternatives evaluated are estimated to provide both cost and dose reductions. Major reductions in transportation system dose and cost are estimated to result from using higher-capacity rail and truck casks, and particularly when replacing legalweight truck casks with ''advanced design'' overweight truck casks. The greatest annual dose reduction to the highest exposed individual workers (i.e., at the repository) is estimated to be achieved by using remote handling equipment for the cask handling operations at the repository. Additional shielding is also effective in reducing doses to both radiation workers at the reactor and repository and to transport workers. 69 refs., 36 figs., 156 tabs.

  20. Dose-dependent effects of gamma radiation on lettuce (Lactuca sativa var. capitata) seedlings.

    PubMed

    Marcu, Delia; Cristea, Victoria; Daraban, Liviu

    2013-03-01

    Abstract Purpose: The objectives of this study were to determine the effects of gamma radiation on lettuce growth and development, as well as on the content of photosynthetic pigments in 28 days lettuce leaf. Lettuce dry seeds were exposed to a (60)Co [Cobalt-60] gamma source at doses ranging from 2-70 Gray (Gy). The photosynthetic pigment content was determined spectrophotometrically. Our results showed that an irradiation dose between of 2-30 Gy enhanced the growth parameters (final germination percentage, germination index, root and hypocotyl length) as compared to untreated plants. Seed germination test revealed that 30 Gy irradiation dose induced the highest increase of growth parameters, while at 70 Gy a significant decrease of plant vegetative growth was recorded. The results indicated that exposing the seeds at doses ranging from 2-30 Gy enhanced the photosynthetic pigments (chlorophyll a, chlorophyll b, carotenoids) content, while at higher doses (70 Gy)) the decrease of the assimilatory pigments was noticed. The present results suggested that seed treatment with gamma radiations (0-30 Gy) was effective in stimulating plant growth and development, as well as the content of assimilatory pigments. At a higher dose of 70 Gy, there was a drastic reduction in the length of shoots and roots and also in the total chlorophyll content. These observations confirm that ionizing radiation stimulates physiological parameters up to certain low doses, and then it inhibits these parameters at higher doses.

  1. Delayed Numerical Chromosome Aberrations in Human Fibroblasts by Low Dose of Radiation

    PubMed Central

    Cho, Yoon Hee; Kim, Su Young; Woo, Hae Dong; Kim, Yang Jee; Ha, Sung Whan; Chung, Hai Won

    2015-01-01

    Radiation-induced genomic instability refers to a type of damage transmitted over many generations following irradiation. This delayed impact of radiation exposure may pose a high risk to human health and increases concern over the dose limit of radiation exposure for both the public and radiation workers. Therefore, the development of additional biomarkers is still needed for the detection of delayed responses following low doses of radiation exposure. In this study, we examined the effect of X-irradiation on delayed induction of numerical chromosomal aberrations in normal human fibroblasts irradiated with 20, 50 and 100 cGy of X-rays using the micronucleus-centromere assay. Frequencies of centromere negative- and positive-micronuclei, and aneuploidy of chromosome 1 and 4 were analyzed in the surviving cells at 28, 88 and 240 h after X-irradiation. X-irradiation increased the frequency of micronuclei (MN) in a dose-dependent manner in the cells at all measured time-points, but no significant differences in MN frequency among cell passages were observed. Aneuploid frequency of chromosomes 1 and 4 increased with radiation doses, and a significantly higher frequency of aneuploidy was observed in the surviving cells analyzed at 240 h compared to 28 h. These results indicate that low-dose of X-irradiation can induce delayed aneuploidy of chromosomes 1 and 4 in normal fibroblasts. PMID:26633443

  2. Radiation equivalent dose simulations for long-term interplanetary flights

    NASA Astrophysics Data System (ADS)

    Dobynde, M. I.; Drozdov, A.; Shprits, Y. Y.

    2016-12-01

    Cosmic particle radiation is a limiting factor for the human interplanetary flights. The unmanned flights inside heliosphere and human flights inside of magnetosphere tend to become a routine procedure, whereas there have been only few shot term human flights out of it (Apollo missions 1969-1972) with maximum duration less than a month. Long-term human flights set much higher requirements to the radiation shielding, primarily because of long exposition to cosmic radiation. Inside the helosphere there are two main sources of cosmic radiation: galactic cosmic rays (GCR) and soalr particle events (SPE). GCR come from the outside of heliosphere forming a background of overall radiation that affects the spacecraft. The intensity of GCR is varied according to solar activity, increasing with solar activity decrease and backward, with the modulation time (time between nearest maxima) of 11 yeas. SPE are shot term events, comparing to GCR modulation time, but particle fluxes are much more higher. The probability of SPE increases with the increase of solar activity. Time dependences of the intensity of these two components encourage looking for a time window of flight, when intensity and effect of GCR and SPE would be minimized. Combining GEANT4 Monte Carlo simulations with time dependent model of GCR spectra and data on SPE spectra we show the time dependence of the radiation dose in an anthropomorphic human phantom inside the shielding capsule. Different types of particles affect differently on the human providing more or less harm to the tissues. We use quality factors to recalculate absorbed dose into biological equivalent dose, which give more information about risks for astronaut's health. Incident particles provide a large amount of secondary particles while propagating through the shielding capsule. We try to find an optimal combination of shielding material and thickness, that will effectively decrease the incident particle energy, at the same time minimizing flow

  3. Predictive aging results in radiation environments

    NASA Astrophysics Data System (ADS)

    Gillen, Kenneth T.; Clough, Roger L.

    1993-06-01

    We have previously derived a time-temperature-dose rate superposition methodology, which, when applicable, can be used to predict polymer degradation versus dose rate, temperature and exposure time. This methodology results in predictive capabilities at the low dose rates and long time periods appropriate, for instance, to ambient nuclear power plant environments. The methodology was successfully applied to several polymeric cable materials and then verified for two of the materials by comparisons of the model predictions with 12 year, low-dose-rate aging data on these materials from a nuclear environment. In this paper, we provide a more detailed discussion of the methodology and apply it to data obtained on a number of additional nuclear power plant cable insulation (a hypalon, a silicone rubber and two ethylene-tetrafluoroethylenes) and jacket (a hypalon) materials. We then show that the predicted, low-dose-rate results for our materials are in excellent agreement with long-term (7-9 year) low-dose-rate results recently obtained for the same material types actually aged under bnuclear power plant conditions. Based on a combination of the modelling and long-term results, we find indications of reasonably similar degradation responses among several different commercial formulations for each of the following "generic" materials: hypalon, ethylene-tetrafluoroethylene, silicone rubber and PVC. If such "generic" behavior can be further substantiated through modelling and long-term results on additional formulations, predictions of cable life for other commercial materials of the same generic types would be greatly facilitated.

  4. High-dose radiation sensor with wireless optical detection

    NASA Astrophysics Data System (ADS)

    Knapkiewicz, Paweł; Augustyniak, Izabela; Sareło, Katarzyna; Gorecka-Drzazga, Anna; Dziuban, Jan

    2017-05-01

    We present a miniature silicon-glass MEMS sensor for measurement of high doses of ionizing radiation (above 10 kGy) using a novel wireless optical detection method. The radiation sensor is a miniaturized version of the so-called hydrogen dosimeter. An amount of high-density polyethylene, located inside the MEMS sensor, degrades under ionizing radiation, releasing gaseous hydrogen. The increasing pressure deflects the thin silicon membrane. The sensor’s destructive and proportional modes of work are also proposed. In the destructive mode, sensors provide in situ information on excessive and discrete levels of radiation. The optical detection method is based on an optical head consisting of a moving membrane and a silicon screen with a matrix of micro-holes. Laser light is reflected from the membrane and scattered when the membrane is deflected, in the process illuminating the holes on the silicon screen. The number of illuminated holes is a function of the degree of membrane deflection; the transformation of the holes to the deflection allows for the calculation of pressure and eventually the dose of ionizing radiation.

  5. Non-uniform dose distributions in cranial radiation therapy

    NASA Astrophysics Data System (ADS)

    Bender, Edward T.

    Radiation treatments are often delivered to patients with brain metastases. For those patients who receive radiation to the entire brain, there is a risk of long-term neuro-cognitive side effects, which may be due to damage to the hippocampus. In clinical MRI and CT scans it can be difficult to identify the hippocampus, but once identified it can be partially spared from radiation dose. Using deformable image registration we demonstrate a semi-automatic technique for obtaining an estimated location of this structure in a clinical MRI or CT scan. Deformable image registration is a useful tool in other areas such as adaptive radiotherapy, where the radiation oncology team monitors patients during the course of treatment and adjusts the radiation treatments if necessary when the patient anatomy changes. Deformable image registration is used in this setting, but there is a considerable level of uncertainty. This work represents one of many possible approaches at investigating the nature of these uncertainties utilizing consistency metrics. We will show that metrics such as the inverse consistency error correlate with actual registration uncertainties. Specifically relating to brain metastases, this work investigates where in the brain metastases are likely to form, and how the primary cancer site is related. We will show that the cerebellum is at high risk for metastases and that non-uniform dose distributions may be advantageous when delivering prophylactic cranial irradiation for patients with small cell lung cancer in complete remission.

  6. Influence of flat-panel fluoroscopic equipment variables on cardiac radiation doses.

    PubMed

    Nickoloff, Edward L; Lu, Zheng Feng; Dutta, Ajoy; So, James; Balter, Stephen; Moses, Jeffrey

    2007-01-01

    To assess the influence of physician-selectable equipment variables on the potential radiation dose reductions during cardiac catheterization examinations using modern imaging equipment. A modern bi-plane angiography unit with flat-panel image receptors was used. Patients were simulated with 15-30 cm of acrylic plastic. The variables studied were: patient thickness, fluoroscopy pulse rates, record mode frame rates, image receptor field-of-view (FoV), automatic dose control (ADC) mode, SID/SSD geometry setting, automatic collimation, automatic positioning, and others. Patient radiation doses double for every additional 3.5-4.5 cm of soft tissue. The dose is directly related to the imaging frame rate; a decrease from 30 pps to 15 pps reduces the dose by about 50%. The dose is related to [(FoV)(-N )] where 2.0 < N < 3.0. Suboptimal positioning of the patient can nearly double the dose. The ADC system provides three selections that can vary the radiation level by 50%. For pediatric studies (2-5 years old), the selection of equipment variables can result in entrance radiation doses that range between 6 and 60 cGy for diagnostic cases and between 15 and 140 cGy for interventional cases. For adult studies, the equipment variables can produce entrance radiation doses that range between 13 and 130 cGy for diagnostic cases and between 30 and 400 cGy for interventional cases. Overall dose reductions of 70-90% can be achieved with pediatric patients and about 90% with adult patients solely through optimal selection of equipment variables.

  7. A comparative study of space radiation organ doses and associated cancer risks using PHITS and HZETRN.

    PubMed

    Bahadori, Amir A; Sato, Tatsuhiko; Slaba, Tony C; Shavers, Mark R; Semones, Edward J; Van Baalen, Mary; Bolch, Wesley E

    2013-10-21

    NASA currently uses one-dimensional deterministic transport to generate values of the organ dose equivalent needed to calculate stochastic radiation risk following crew space exposures. In this study, organ absorbed doses and dose equivalents are calculated for 50th percentile male and female astronaut phantoms using both the NASA High Charge and Energy Transport Code to perform one-dimensional deterministic transport and the Particle and Heavy Ion Transport Code System to perform three-dimensional Monte Carlo transport. Two measures of radiation risk, effective dose and risk of exposure-induced death (REID) are calculated using the organ dose equivalents resulting from the two methods of radiation transport. For the space radiation environments and simplified shielding configurations considered, small differences (<8%) in the effective dose and REID are found. However, for the galactic cosmic ray (GCR) boundary condition, compensating errors are observed, indicating that comparisons between the integral measurements of complex radiation environments and code calculations can be misleading. Code-to-code benchmarks allow for the comparison of differential quantities, such as secondary particle differential fluence, to provide insight into differences observed in integral quantities for particular components of the GCR spectrum.

  8. [Management and delivery of radiation dose distribution images using the Internet].

    PubMed

    Onogi, Y; Nakagawa, K; Aoki, Y; Kozuka, T; Toyoda, T; Sasaki, Y

    1998-01-01

    Dose distribution images play important roles in the management of cancer patients. To date hard copies of these images have been stored and referred to by radiation oncologists as needed. In most cases, these images were not available to medical personnel outside the radiation oncology department. We have developed a mechanism in the hospital to access these dose distribution images via WWW (World Wide Web). A screen snapshot of a dose distribution image on the CRT of a treatment planning machine is copied to the WWW server and converted to a GIF image. Similarly, we can register dose volume histograms and digitally reconstructed radiographs on the WWW. Medical personnel throughout the hospital can access the images through the WWW browser. As a result, radiation oncologists are given detailed information on target definition in treatment planning by expert physicians. The system also helps co-medical staff in understanding dose distributions and predicting radiation injuries. At the same time, it actualizes an electronic archive of dose distribution images, which is a database for quick and reliable review, evaluation and comparison of treatment plans. This technique also furthers a close relationship among radiation oncologists, physicians, and co-medical personnel.

  9. Review and Evaluation of Updated Research on the Health Effects Associated with Low-Dose Ionizing Radiation

    SciTech Connect

    Dauer, Lawrence T.; Brooks, Antone L.; Hoel, David G.; Morgan, William F.; Stram, Daniel; Tran, Phung

    2010-07-01

    Potential health effects of low levels of radiation have predominantly been based on those effects observed at high levels of radiation. The authors have reviewed more than 200 percent publications in radiobiology and epidermiology related to low dose radiation and concluded that recent radiobiological studies at low-doses; that doses <100 mSv in a single exposure appear to be too small to allow epidermiological detection of statistically significant excess cancers in the presence of naturally occurring cancers; that low dose radiation research should to holistic, systems-based approaches to develop models that define the shape of the dose-response relationships at low doses; and that these results should be combined with the latest epidermiology to produce a comprehensive understanding of radiation effects that addresses both damage, likely with a linear effect, and response, possibly with non-linear consequences.

  10. Estimation of radiation-induced cancer from three-dimensional dose distributions: Concept of organ equivalent dose

    SciTech Connect

    Schneider, Uwe . E-mail: uwe.schneider@psi.ch; Zwahlen, Daniel; Ross, Dieter; Kaser-Hotz, Barbara

    2005-04-01

    Purpose: Estimates of secondary cancer risk after radiotherapy are becoming more important for comparative treatment planning. Modern treatment planning systems provide accurate three-dimensional dose distributions for each individual patient. These data open up new possibilities for more precise estimates of secondary cancer incidence rates in the irradiated organs. We report a new method to estimate organ-specific radiation-induced cancer incidence rates. The concept of an organ equivalent dose (OED) for radiation-induced cancer assumes that any two dose distributions in an organ are equivalent if they cause the same radiation-induced cancer incidence. Methods and Materials: The two operational parameters of the OED concept are the organ-specific cancer incidence rate at low doses, which is taken from the data of the atomic bomb survivors, and cell sterilization at higher doses. The effect of cell sterilization in various organs was estimated by analyzing the secondary cancer incidence data of patients with Hodgkin's disease who were treated with radiotherapy in between 1962 and 1993. The radiotherapy plans used at the time the patients had been treated were reconstructed on a fully segmented whole body CT scan. The dose distributions were calculated in individual organs for which cancer incidence data were available. The model parameter that described cell sterilization was obtained by analyzing the dose and cancer incidence rates for the individual organs. Results: We found organ-specific cell radiosensitivities that varied from 0.017 for the mouth and pharynx up to 1.592 for the bladder. Using the two model parameters (organ-specific cancer incidence rate and the parameter characterizing cell sterilization), the OED concept can be applied to any three-dimensional dose distribution to analyze cancer incidence. Conclusion: We believe that the concept of OED presented in this investigation represents a first step in assessing the potential risk of secondary

  11. Problems in evaluating radiation dose via terrestrial and aquatic pathways.

    PubMed

    Vaughan, B E; Soldat, J K; Schreckhise, R G; Watson, E C; McKenzie, D H

    1981-12-01

    This review is concerned with exposure risk and the environmental pathways models used for predictive assessment of radiation dose. Exposure factors, the adequacy of available data, and the model subcomponents are critically reviewed from the standpoint of absolute error propagation. Although the models are inherently capable of better absolute accuracy, a calculated dose is usually overestimated by from two to six orders of magnitude, in practice. The principal reason for so large an error lies in using "generic" concentration ratios in situations where site specific data are needed. Major opinion of the model makers suggests a number midway between these extremes, with only a small likelihood of ever underestimating the radiation dose. Detailed evaluations are made of source considerations influencing dose (i.e., physical and chemical status of released material); dispersal mechanisms (atmospheric, hydrologic and biotic vector transport); mobilization and uptake mechanisms (i.e., chemical and other factors affecting the biological availability of radioelements); and critical pathways. Examples are shown of confounding in food-chain pathways, due to uncritical application of concentration ratios. Current thoughts of replacing the critical pathways approach to calculating dose with comprehensive model calculations are also shown to be ill-advised, given present limitations in the comprehensive data base. The pathways models may also require improved parametrization, as they are not at present structured adequately to lend themselves to validation. The extremely wide errors associated with predicting exposure stand in striking contrast to the error range associated with the extrapolation of animal effects data to the human being.

  12. Biological detection of low radiation doses with integrated photothermal assay

    NASA Astrophysics Data System (ADS)

    Zharov, Vladimir P.; Viegas, Mark; Soderberg, Lee S. F.

    2005-04-01

    The goal of this paper was to evaluate the diagnostic value of integrated photothermal (PT) assay with additional fluorescent and photoacoustic (PA) modules to assess both the "safety limit" of exposure to ionizing γ-radiation and optimal therapeutic doses for cancer treatment. With this assay, the influences of γ irradiation on cancer cells (pancreatic-AR42J and hepatocytes-hepG2) and healthy cells (mouse lymphocytes and erythrocytes) was examined as a function of exposure dose (0.6-5 Gy) and time after irradiation, in vitro and in vivo. Independent verification of data obtained with conventional assays revealed that integrated PT assay allowed us to detect the different stages of radiation impact, including changes in cell metabolism at low dose, or stages related to cell death (apoptosis and necrosis) at high doses with a threshold sensitivity of at least three orders of magnitude better than existing assays. Also, PT assay was capable of quantitatively differentiating the biological action of γ irradiation alone and in combination with drug and nicotine impact. Finally, we demonstrated on an animal model that IPT assay has the potential for use in routine rapid evaluation of biological consequences of low-dose exposure a few days after irradiation.

  13. Occupational doses in radiation oncology in Manitoba--1980 to 1986

    SciTech Connect

    Huda, W.; Bews, J.; Sourkes, A.M. )

    1989-10-01

    The province of Manitoba (population of 1.0 million) has two radiotherapy centers employing a number of people, of whom about 60 are exposed to radiation during the course of their work. The individual and collective radiation doses to these workers, as recorded by thermoluminescent dosimeter plaques, were reviewed for the period 1980 to 1986. Whole-body doses to radiotherapy technologists responsible for operating the treatment machines and brachytherapy afterloading procedures ranged from 0.5 to 2.5 mSv y-1, whereas the corresponding doses to nursing staff working on a hospital brachytherapy ward were about 1.0 mSv y-1. The collective occupational dose from radiotherapy in Manitoba was approximately 70 person-mSv. Trends show individual operator and collective doses to be increasing at a higher rate than the number of patients undergoing radiotherapy. Occupational exposure in radiotherapy in this province was found to be comparable to that encountered in nuclear medicine in Manitoba and greater than that in diagnostic radiology.

  14. Radiological mapping of Kelantan, Malaysia, using terrestrial radiation dose rate.

    PubMed

    Garba, Nuraddeen Nasiru; Ramli, Ahmad Termizi; Saleh, Muneer Aziz; Sanusi, Syazwan Mohd; Gabdo, Hamman Tukur

    2016-06-01

    Measurements of the environmental terrestrial gamma radiation dose rate (TGRD) in each district of Kelantan state, Malaysia, were carried out using a portable hand-held radiation survey meter and global positioning system. The measurements were done based on geology and soil types of the area. The mean TGRD was found to be 209 nGy h(-1). Few areas of relatively enhanced activity were observed in Pasir Mas, Tanah Merah and Jeli districts, which have a mean TGRD between 300 and 500 nGy h(-1). An isodose map of the area was produced using ArcGIS software version 9.3.

  15. Radiation dose of cardiac CT--what is the evidence?

    PubMed

    Alkadhi, Hatem

    2009-06-01

    Current evidence and most pertinent literature on the radiation dose of cardiac computed tomography (CT) for the noninvasive assessment of coronary artery disease are reviewed. The various means for adjusting CT protocols to lower the radiation to a level that is as low as reasonably achievable are discussed. It is shown that for the target population of cardiac CT, the direct visualization of the heart and coronary arteries outweighs the hypothetical risk of the investigation, provided that indications are prudent and the protocols appropriate.

  16. The effects of x-ray beam hardening on detective quantum efficiency and radiation dose.

    PubMed

    Wong, Molly Donovan; Wu, Xizeng; Liu, Hong

    2011-01-01

    The goal of this preliminary study was to investigate the effects of x-ray beam hardening on the detective quantum efficiency (DQE) and the radiation dose of an inline x-ray imaging system. The ability to decrease the risk of harmful radiation to the patient without compromising the detection capability would more effectively balance the tradeoff between image quality and radiation dose, and therefore benefit the fields of diagnostic x-ray imaging, especially mammography. The DQE and the average glandular dose were both calculated under the same experimental conditions for a range of beam hardening levels, corresponding to no added beam hardening and two thicknesses each of Rhodium (Rh) and Molybdenum (Mo) filters. The dose calculation results demonstrate a reduction of 15% to 24% for the range of beam hardening levels. The comparison of all quantities comprising the DQE exhibit very close correlation between the results obtained without added beam hardening to the results corresponding to the range of beam hardening levels. For the specific experimental conditions utilized in this preliminary study, the results are an indication that the use of beam hardening holds the potential to reduce the radiation dose without decreasing the performance of the system. Future studies will seek to apply this method in a clinical environment and perform a comprehensive image quality evaluation, in an effort to further evaluate the potential of beam hardening to balance the tradeoff between dose and image quality.

  17. Radiation doses from Hanford site releases to the atmosphere

    SciTech Connect

    Farris, W.T.; Napier, B.A.; Ikenberry, T.A.

    1994-06-01

    Radiation doses to individuals were estimated for the years 1944-1992. The dose estimates were based on the radioactive-releases from the Hanford Site in south central Washington. Conceptual models and computer codes were used to reconstruct doses through the early 1970s. The published Hanford Site annual environmental data were used to complete the does history through 1992. The most significant exposure pathway was found to be the consumption of cow`s milk containing iodine-131. For the atmospheric pathway, median cumulative dose estimates to the thyroid of children ranged from < 0.1 to 235 rad throughout the area studied. The geographic distribution of the dose levels was directly related to the pattern of iodine-131 deposition and was affected by the distribution of commercial milk and leafy vegetables. For the atmospheric pathway, the-highest estimated cumulative-effective-dose-equivalent (EDE) to an adult was estimated to be 1 rem at Ringold, Washington for the period 1944-1992. For the Columbia River pathway, cumulative EDE estimates ranged from <0.5 to l.5 rem cumulative dose to maximally exposed adults downriver from the Hanford Site for the years 1944-1992. The most significant river exposure pathway was consumption of resident fish containing phosphorus-32 and zinc-65.

  18. Radiation doses in interventional radiology procedures: the RAD-IR study: part I: overall measures of dose.

    PubMed

    Miller, Donald L; Balter, Stephen; Cole, Patricia E; Lu, Hollington T; Schueler, Beth A; Geisinger, Michael; Berenstein, Alejandro; Albert, Robin; Georgia, Jeffrey D; Noonan, Patrick T; Cardella, John F; St George, James; Russell, Eric J; Malisch, Tim W; Vogelzang, Robert L; Miller, George L; Anderson, Jon

    2003-06-01

    To determine patient radiation doses for interventional radiology and neuroradiology procedures, to identify procedures associated with higher radiation doses, and to determine the effects of various parameters on patient doses. A prospective observational study was performed at seven academic medical centers. Each site contributed demographic and radiation dose data for subjects undergoing specific procedures in fluoroscopic suites equipped with built-in cumulative dose (CD) and dose-area-product (DAP) measurement capability compliant with International Electrotechnical Commission standard 60601-2-43. The accuracy of the dosimetry was confirmed by comprehensive measurements and by frequent consistency checks performed over the course of the study. Data were collected on 2,142 instances of interventional radiology procedures, 48 comprehensive physics evaluations, and 581 periodic consistency checks from the 12 fluoroscopic units in the study. There were wide variations in dose and statistically significant differences in fluoroscopy time, number of images, DAP, and CD for different instances of the same procedure, depending on the nature of the lesion, its anatomic location, and the complexity of the procedure. For the 2,142 instances, observed CD and DAP correlate well overall (r = 0.83, P <.000001), but correlation in individual instances is poor. The same is true for the correlation between fluoroscopy time and CD (r = 0.79, P <.000001). The correlation between fluoroscopy time and DAP (r = 0.60, P <.000001) is not as good. In 6% of instances (128 of 2,142), which were principally embolization procedures, transjugular intrahepatic portosystemic shunt (TIPS) procedures, and renal/visceral artery stent placements, CD was greater than 5 Gy. Most procedures studied can result in clinically significant radiation dose to the patient, even when performed by trained operators with use of dose-reducing technology and modern fluoroscopic equipment. Embolization procedures

  19. Marked reduction of effective radiation dose in patients undergoing CT coronary angiography using prospective ECG gating.

    PubMed

    Freeman, Anthony; Learner, Ruth; Eggleton, Simon; Lambros, John; Friedman, Daniel

    2011-08-01

    Coronary CT angiography (CCTA) is a rapidly evolving technology which can characterise and image sub clinical atherosclerotic plaque and visualise anatomy and quantitate stenosis. Concern about radiation exposure has limited the uptake of this technology. The aim of this study was to review the radiation dose data in 2298 consecutive patients referred to a single centre in an Australian outpatient setting over 27 months using all available radiation dose reduction strategies. Prospective ECG gating ("step and shoot") was used preferentially in 2025 patients with a mean effective dose of 3.39 ± 1.84 mSv (range 0.86-12.6 mSv). For clinical reasons only 273 patients required retrospective ECG gating, mean dose 19.21 ± 5.58 mSv (range 2.4-34.9 mSv) resulting in an 85.7% reduction in dose for the majority of patients with the low dose technique. In conclusion, most patients referred for routine CCTA can be studied with a radiation dose comparable to invasive X-ray angiography and less than radionuclide myocardial perfusion imaging. Copyright © 2011 Australasian Society of Cardiac and Thoracic Surgeons and the Cardiac Society of Australia and New Zealand. Published by Elsevier B.V. All rights reserved.

  20. Ionizing radiation-induced mutagenesis: radiation studies in Neurospora predictive for results in mammalian cells

    NASA Technical Reports Server (NTRS)

    Evans, H. H.; DeMarini, D. M.

    1999-01-01

    Ionizing radiation was the first mutagen discovered and was used to develop the first mutagenicity assay. In the ensuing 70+ years, ionizing radiation became a fundamental tool in understanding mutagenesis and is still a subject of intensive research. Frederick de Serres et al. developed and used the Neurospora crassa ad-3 system initially to explore the mutagenic effects of ionizing radiation. Using this system, de Serres et al. demonstrated the dependence of the frequency and spectra of mutations induced by ionizing radiation on the dose, dose rate, radiation quality, repair capabilities of the cells, and the target gene employed. This work in Neurospora predicted the subsequent observations of the mutagenic effects of ionizing radiation in mammalian cells. Modeled originally on the mouse specific-locus system developed by William L. Russell, the N. crassa ad-3 system developed by de Serres has itself served as a model for interpreting the results in subsequent systems in mammalian cells. This review describes the primary findings on the nature of ionizing radiation-induced mutagenesis in the N. crassa ad-3 system and the parallel observations made years later in mammalian cells.

  1. Ionizing radiation-induced mutagenesis: radiation studies in Neurospora predictive for results in mammalian cells

    NASA Technical Reports Server (NTRS)

    Evans, H. H.; DeMarini, D. M.

    1999-01-01

    Ionizing radiation was the first mutagen discovered and was used to develop the first mutagenicity assay. In the ensuing 70+ years, ionizing radiation became a fundamental tool in understanding mutagenesis and is still a subject of intensive research. Frederick de Serres et al. developed and used the Neurospora crassa ad-3 system initially to explore the mutagenic effects of ionizing radiation. Using this system, de Serres et al. demonstrated the dependence of the frequency and spectra of mutations induced by ionizing radiation on the dose, dose rate, radiation quality, repair capabilities of the cells, and the target gene employed. This work in Neurospora predicted the subsequent observations of the mutagenic effects of ionizing radiation in mammalian cells. Modeled originally on the mouse specific-locus system developed by William L. Russell, the N. crassa ad-3 system developed by de Serres has itself served as a model for interpreting the results in subsequent systems in mammalian cells. This review describes the primary findings on the nature of ionizing radiation-induced mutagenesis in the N. crassa ad-3 system and the parallel observations made years later in mammalian cells.

  2. Systematic measurements of whole-body imaging dose distributions in image-guided radiation therapy

    SciTech Connect

    Haelg, Roger A.; Besserer, Juergen; Schneider, Uwe

    2012-12-15

    Purpose: The full benefit of the increased precision of contemporary treatment techniques can only be exploited if the accuracy of the patient positioning is guaranteed. Therefore, more and more imaging modalities are used in the process of the patient setup in clinical routine of radiation therapy. The improved accuracy in patient positioning, however, results in additional dose contributions to the integral patient dose. To quantify this, absorbed dose measurements from typical imaging procedures involved in an image-guided radiation therapy treatment were measured in an anthropomorphic phantom for a complete course of treatment. The experimental setup, including the measurement positions in the phantom, was exactly the same as in a preceding study of radiotherapy stray dose measurements. This allows a direct combination of imaging dose distributions with the therapy dose distribution. Methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The dose distributions from imaging devices used with treatment machines from the manufacturers Accuray, Elekta, Siemens, and Varian and from computed tomography scanners from GE Healthcare were determined and the resulting effective dose was calculated. The list of investigated imaging techniques consisted of cone beam computed tomography (kilo- and megavoltage), megavoltage fan beam computed tomography, kilo- and megavoltage planar imaging, planning computed tomography with and without gating methods and planar scout views. Results: A conventional 3D planning CT resulted in an effective dose additional to the treatment stray dose of less than 1 mSv outside of the treated volume, whereas a 4D planning CT resulted in a 10 times larger dose. For a daily setup of the patient with two planar kilovoltage images or with a fan beam CT at the TomoTherapy unit, an additional effective dose outside of the treated volume of less than 0.4 mSv and 1

  3. The Effect of High-Dose Ionizing Radiation on the Astrobiological Model Lichen Circinaria gyrosa

    NASA Astrophysics Data System (ADS)

    de la Torre, Rosa; Zélia Miller, Ana; Cubero, Beatriz; Martín-Cerezo, M. Luisa; Raguse, Marina; Meeßen, Joachim

    2017-02-01

    The lichen Circinaria gyrosa is an astrobiological model defined by its high capacity of resistance to space conditions and to a simulated martian environment. Therefore, it became part of the currently operated BIOMEX experiment on board the International Space Station and the recent STARLIFE campaign to study the effects of four types of space-relevant ionizing radiation. The samples were irradiated with helium and iron ions at doses up to 2 kGy, with X-rays at doses up to 5 kGy and with γ rays at doses from 6 to 113 kGy. Results on C. gyrosa's resistance to simulated space ionizing radiation and its post-irradiation viability were obtained by (i) chlorophyll a fluorescence of photosystem II (PSII), (ii) epifluorescence microscopy, (iii) confocal laser scanning microscopy (CLSM), and (iv) field emission scanning electron microscopy (FESEM). Results of photosynthetic activity and epifluorescence show no significant changes up to a dose of 1 kGy (helium ions), 2 kGy (iron ions), 5 kGy (X-rays) - the maximum doses applied for those radiation qualities - as well as a dose of 6 kGy of γ irradiation, which was the lowest dose applied for this low linear energy transfer (LET) radiation. Significant damage in a dose-related manner was observed only at much higher doses of γ irradiation (up to 113 kGy). These data corroborate the findings of the parallel STARLIFE studies on the effects of ionizing radiation on the lichen Circinaria gyrosa, its isolated photobiont, and the lichen Xanthoria elegans.

  4. Meta-analysis of non-tumour doses for radiation-induced cancer on the basis of dose-rate.

    PubMed

    Tanooka, Hiroshi

    2011-07-01

    Quantitative analysis of cancer risk of ionising radiation as a function of dose-rate. Non-tumour dose, D(nt), defined as the highest dose of radiation at which no statistically significant tumour increase was observed above the control level, was analysed as a function of dose-rate of radiation. An inverse correlation was found between D(nt) and dose-rate of the radiation. D(nt) increased 20-fold with decreasing dose-rate from 1-10(-8) Gy/min for whole body irradiation with low linear energy transfer (LET) radiation. Partial body radiation also showed a dose-rate dependence with a 5- to 10-fold larger D(nt) as dose rate decreased. The dose-rate effect was also found for high LET radiation but at 10-fold lower D(nt) levels. The cancer risk of ionising radiation varies 1000-fold depending on the dose-rate of radiation and exposure conditions. This analysis explains the discrepancy of cancer risk between A-bomb survivors and radium dial painters.

  5. Radiation doses received in the United Kingdom breast screening programme in 2010 to 2012

    PubMed Central

    Oduko, Jennifer M

    2016-01-01

    Objectives: To review the radiation doses received by women attending the UK breast-screening programme between 2010 and 2012. To compare doses with previous years and to quantify the impact on dose of changing from analogue to digital imaging and to analyse doses by type of imaging system. Methods: Measurements of doses to samples of about 50–100 women attending for screening were collected across the whole of the UK breast-screening programme. Results: Data were collected for 87,122 exposures, using 449 X-ray sets, for 25,408 women. The average mean glandular dose (MGD) was 1.79 mGy for mediolateral oblique images and 1.58 mGy for craniocaudal images. The average MGD per two-view examination was 4.01 mGy for film-screen imaging and 3.03 mGy for direct digital radiography (DR) and 4.69 mGy for computed radiography. Conclusion: The MGD to women attending breast screening has been reduced on average by about 25% where DR systems have replaced film-screen systems. The dose reduction was greatest for breasts with the largest compressed thickness. There are large variations in dose between the different models of DR system provided by different manufacturers. There should be further work to ensure that all DR systems are operated at the optimal dose level to ensure the best cancer detection while balancing the detriment caused by using radiation. Advances in knowledge: Changes in the radiation dose in breast screening over time have been determined. Specifically, the impact on radiation dose of introducing different types of DR and computed radiography system into breast screening has been quantified. PMID:26654386

  6. Radiation dose to workers due to the inhalation of dust during granite fabrication.

    PubMed

    Zwack, L M; McCarthy, W B; Stewart, J H; McCarthy, J F; Allen, J G

    2014-03-01

    There has been very little research conducted to determine internal radiation doses resulting from worker exposure to ionising radiation in granite fabrication shops. To address this issue, we estimated the effective radiation