Sample records for reverse isotope dilution

  1. Reverse isotope dilution method for determining benzene and metabolites in tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bechtold, W.E.; Sabourin, P.J.; Henderson, R.F.

    1988-07-01

    A method utilizing reverse isotope dilution for the analysis of benzene and its organic soluble metabolites in tissues of rats and mice is presented. Tissues from rats and mice that had been exposed to radiolabeled benzene were extracted with ethyl acetate containing known, excess quantities of unlabeled benzene and metabolites. Butylated hydroxytoluene was added as an antioxidant. The ethyl acetate extracts were analyzed with semipreparative reversed-phase HPLC. Isolated peaks were collected and analyzed for radioactivity (by liquid scintillation spectrometry) and for mass (by UV absorption). The total amount of each compound present was calculated from the mass dilution of themore » radiolabeled isotope. This method has the advantages of high sensitivity, because of the high specific activity of benzene, and relative stability of the analyses, because of the addition of large amounts of unlabeled carrier analogue.« less

  2. Gluconeogenesis from labeled carbon: estimating isotope dilution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kelleher, J.K.

    1986-03-01

    To estimate the rate of gluconeogenesis from steady-state incorporation of labeled 3-carbon precursors into glucose, isotope dilution must be considered so that the rate of labeling of glucose can be quantitatively converted to the rate of gluconeogenesis. An expression for the value of this isotope dilution can be derived using mathematical techniques and a model of the tricarboxylic acid (TCA) cycle. The present investigation employs a more complex model than that used in previous studies. This model includes the following pathways that may affect the correction for isotope dilution: 1) flux of 3-carbon precursor to the oxaloacetate pool via acetyl-CoAmore » and the TCA cycle; 2) flux of 4- or 5-carbon compounds into the TCA cycle; 3) reversible flux between oxaloacetate (OAA) and pyruvate and between OAA and fumarate; 4) incomplete equilibrium between OAA pools; and 5) isotope dilution of 3-carbon tracers between the experimentally measured pool and the precursor for the TCA-cycle OAA pool. Experimental tests are outlined which investigators can use to determine whether these pathways are significant in a specific steady-state system. The study indicated that flux through these five pathways can significantly affect the correction for isotope dilution. To correct for the effects of these pathways an alternative method for calculating isotope dilution is proposed using citrate to relate the specific activities of acetyl-CoA and OAA.« less

  3. Evaluation of the combined measurement uncertainty in isotope dilution by MC-ICP-MS.

    PubMed

    Fortunato, G; Wunderli, S

    2003-09-01

    The combination of metrological weighing, the measurement of isotope amount ratios by a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) and the use of high-purity reference materials are the cornerstones to achieve improved results for the amount content of lead in wine by the reversed isotope dilution technique. Isotope dilution mass spectrometry (IDMS) and reversed IDMS have the potential to be a so-called primary method, with which close comparability and well-stated combined measurement uncertainties can be obtained. This work describes the detailed uncertainty budget determination using the ISO-GUM approach. The traces of lead in wine were separated from the matrix by ion exchange chromatography after HNO(3)/H(2)O(2) microwave digestion. The thallium isotope amount ratio ( n((205)Tl)/ n((203)Tl)) was used to correct for mass discrimination using an exponential model approach. The corrected lead isotope amount ratio n((206)Pb)/ n((208)Pb) for the isotopic standard SRM 981 measured in our laboratory was compared with ratio values considered to be the least uncertain. The result has been compared in a so-called pilot study "lead in wine" organised by the CCQM (Comité Consultatif pour la Quantité de Matière, BIPM, Paris; the highest measurement authority for analytical chemical measurements). The result for the lead amount content k(Pb) and the corresponding expanded uncertainty U given by our laboratory was:k(Pb)=1.329 x 10-10mol g-1 (amount content of lead in wine)U[k(Pb)]=1.0 x 10-12mol g-1 (expanded uncertainty U=kxuc, k=2)The uncertainty of the main influence parameter of the combined measurement uncertainty was determined to be the isotope amount ratio R(206,B) of the blend between the enriched spike and the sample.

  4. Hyperpolarization of “Neat” Liquids by NMR Signal Amplification by Reversible Exchange

    PubMed Central

    2016-01-01

    We report NMR Signal Amplification by Reversible Exchange (SABRE) hyperpolarization of the rare isotopes in “neat” liquids, each composed only of an otherwise pure target compound with isotopic natural abundance (n.a.) and millimolar concentrations of dissolved catalyst. Pyridine (Py) or Py derivatives are studied at 0.4% isotopic natural abundance 15N, deuterated, 15N enriched, and in various combinations using the SABRE-SHEATH variant (microTesla magnetic fields to permit direct 15N polarization from parahydrogen via reversible binding and exchange with an Ir catalyst). We find that the dilute n.a. 15N spin bath in Py still channels spin order from parahydrogen to dilute 15N spins, without polarization losses due to the presence of 14N or 2H. We demonstrate P15N ≈ 1% (a gain of 2900 fold relative to thermal polarization at 9.4 T) at high substrate concentrations. This fundamental finding has a significant practical benefit for screening potentially hyperpolarizable contrast agents without labeling. The capability of screening at n.a. level of 15N is demonstrated on examples of mono- and dimethyl-substituted Py (picolines and lutidines previously identified as promising pH sensors), showing that the presence of a methyl group in the ortho position significantly decreases SABRE hyperpolarization. PMID:26029349

  5. A novel reversed-phase HPLC method for the determination of urinary creatinine by pre-column derivatization with ethyl chloroformate: comparative studies with the standard Jaffé and isotope-dilution mass spectrometric assays.

    PubMed

    Leung, Elvis M K; Chan, Wan

    2014-02-01

    Creatinine is an important biomarker for renal function diagnosis and normalizing variations in urinary drug/metabolites concentration. Quantification of creatinine in biological fluids such as urine and plasma is important for clinical diagnosis as well as in biomonitoring programs and urinary metabolomics/metabonomics research. Current methods for creatinine determination either are nonselective or involve the use of expensive mass spectrometers. In this paper, a novel reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of creatinine of high hydrophilicity by pre-column derivatization with ethyl chloroformate is presented. N-Ethyloxycarbonylation of creatinine significantly enhanced the hydrophobicity of creatinine, facilitating its chromatographic retention as well as quantification by HPLC. Factors governing the derivatization reaction were studied and optimized. The developed method was validated and applied for the determination of creatinine in rat urine samples. Comparative studies with isotope-dilution mass spectrometric method revealed that the two methods do not yield systematic differences in creatinine concentrations, indicating the HPLC method is suitable for the determination of creatinine in urine samples.

  6. Rapid and precise measurement of serum branched-chain and aromatic amino acids by isotope dilution liquid chromatography tandem mass spectrometry.

    PubMed

    Yang, Ruiyue; Dong, Jun; Guo, Hanbang; Li, Hongxia; Wang, Shu; Zhao, Haijian; Zhou, Weiyan; Yu, Songlin; Wang, Mo; Chen, Wenxiang

    2013-01-01

    Serum branched-chain and aromatic amino acids (BCAAs and AAAs) have emerged as predictors for the future development of diabetes and may aid in diabetes risk assessment. However, the current methods for the analysis of such amino acids in biological samples are time consuming. An isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) method for serum BCAAs and AAAs was developed. The serum was mixed with isotope-labeled BCAA and AAA internal standards and the amino acids were extracted with acetonitrile, followed by analysis using LC/MS/MS. The LC separation was performed on a reversed-phase C18 column, and the MS/MS detection was performed via the positive electronic spray ionization in multiple reaction monitoring mode. Specific analysis of the amino acids was achieved within 2 min. Intra-run and total CVs for the amino acids were less than 2% and 4%, respectively, and the analytical recoveries ranged from 99.6 to 103.6%. A rapid and precise method for the measurement of serum BCAAs and AAAs was developed and may serve as a quick tool for screening serum BCAAs and AAAs in studies assessing diabetes risk.

  7. Liquid chromatography/electrospray ionization/isotopic dilution mass spectrometry analysis of n-(phosphonomethyl) glycine and mass spectrometry analysis of aminomethyl phosphonic acid in environmental water and vegetation matrixes.

    PubMed

    Grey, L; Nguyen, B; Yang, P

    2001-01-01

    A liquid chromatography/electrospray/mass spectrometry (LC/ES/MS) method was developed for the analysis of glyphosate (n-phosphonomethyl glycine) and its metabolite, aminomethyl phosphonic acid (AMPA) using isotope-labelled glyphosate as a method surrogate. Optimized parameters were achieved to derivatize glyphosate and AMPA using 9-fluorenylmethyl chloroformate (FMOC-Cl) in borate buffer prior to a reversed-phase LC analysis. Method spike recovery data obtained using laboratory and real world sample matrixes indicated an excellent correlation between the recovery of the native and isotope-labelled glyphosate. Hence, the first performance-based, isotope dilution MS method with superior precision, accuracy, and data quality was developed for the analysis of glyphosate. There was, however, no observable correlation between the isotope-labelled glyphosate and AMPA. Thus, the use of this procedure for the accurate analysis of AMPA was not supported. Method detection limits established using standard U.S. Environmental Protection Agency protocol were 0.06 and 0.30 microg/L, respectively, for glyphosate and AMPA in water matrixes and 0.11 and 0.53 microg/g, respectively, in vegetation matrixes. Problems, solutions, and the method performance data related to the analysis of chlorine-treated drinking water samples are discussed. Applying this method to other environmental matrixes, e.g., soil, with minimum modifications is possible, assuring accurate, multimedia studies of glyphosate concentration in the environment and the delivery of useful multimedia information for regulatory applications.

  8. Isotope dilution ICP-MS with laser-assisted sample introduction for direct determination of sulfur in petroleum products.

    PubMed

    Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G

    2005-08-01

    Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.

  9. Stable isotope dilution analysis of hydrologic samples by inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Garbarino, John R.; Taylor, Howard E.

    1987-01-01

    Inductively coupled plasma mass spectrometry is employed in the determination of Ni, Cu, Sr, Cd, Ba, Ti, and Pb in nonsaline, natural water samples by stable isotope dilution analysis. Hydrologic samples were directly analyzed without any unusual pretreatment. Interference effects related to overlapping isobars, formation of metal oxide and multiply charged ions, and matrix composition were identified and suitable methods of correction evaluated. A comparability study snowed that single-element isotope dilution analysis was only marginally better than sequential multielement isotope dilution analysis. Accuracy and precision of the single-element method were determined on the basis of results obtained for standard reference materials. The instrumental technique was shown to be ideally suited for programs associated with certification of standard reference materials.

  10. Determination of serum calcium levels by 42Ca isotope dilution inductively coupled plasma mass spectrometry.

    PubMed

    Han, Bingqing; Ge, Menglei; Zhao, Haijian; Yan, Ying; Zeng, Jie; Zhang, Tianjiao; Zhou, Weiyan; Zhang, Jiangtao; Wang, Jing; Zhang, Chuanbao

    2017-11-27

    Serum calcium level is an important clinical index that reflects pathophysiological states. However, detection accuracy in laboratory tests is not ideal; as such, a high accuracy method is needed. We developed a reference method for measuring serum calcium levels by isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS), using 42Ca as the enriched isotope. Serum was digested with 69% ultrapure nitric acid and diluted to a suitable concentration. The 44Ca/42Ca ratio was detected in H2 mode; spike concentration was calibrated by reverse IDMS using standard reference material (SRM) 3109a, and sample concentration was measured by a bracketing procedure. We compared the performance of ID ICP-MS with those of three other reference methods in China using the same serum and aqueous samples. The relative expanded uncertainty of the sample concentration was 0.414% (k=2). The range of repeatability (within-run imprecision), intermediate imprecision (between-run imprecision), and intra-laboratory imprecision were 0.12%-0.19%, 0.07%-0.09%, and 0.16%-0.17%, respectively, for two of the serum samples. SRM909bI, SRM909bII, SRM909c, and GBW09152 were found to be within the certified value interval, with mean relative bias values of 0.29%, -0.02%, 0.10%, and -0.19%, respectively. The range of recovery was 99.87%-100.37%. Results obtained by ID ICP-MS showed a better accuracy than and were highly correlated with those of other reference methods. ID ICP-MS is a simple and accurate candidate reference method for serum calcium measurement and can be used to establish and improve serum calcium reference system in China.

  11. Monitoring Microbial Mineralization Using Reverse Stable Isotope Labeling Analysis by Mid-Infrared Laser Spectroscopy

    PubMed Central

    2017-01-01

    Assessing the biodegradation of organic compounds is a frequent question in environmental science. Here, we present a sensitive, inexpensive, and simple approach to monitor microbial mineralization using reverse stable isotope labeling analysis (RIL) of dissolved inorganic carbon (DIC). The medium for the biodegradation assay contains regular organic compounds and 13C-labeled DIC with 13C atom fractions (x(13C)DIC) higher than natural abundance (typically 2–50%). The produced CO2 (x(13C) ≈ 1.11%) gradually dilutes the initial x(13C)DIC allowing to quantify microbial mineralization using mass-balance calculations. For 13C-enriched CO2 samples, a newly developed isotope ratio mid-infrared spectrometer was introduced with a precision of x(13C) < 0.006%. As an example for extremely difficult and slowly degradable compounds, CO2 production was close to the theoretical stoichiometry for anaerobic naphthalene degradation by a sulfate-reducing enrichment culture. Furthermore, we could measure the aerobic degradation of dissolved organic carbon (DOC) adsorbed to granular activated carbon in a drinking water production plant, which cannot be labeled with 13C. Thus, the RIL approach can be applied to sensitively monitor biodegradation of various organic compounds under anoxic or oxic conditions. PMID:28903553

  12. Measurement of isotope ratios on transient signals by MC-ICP-MS.

    PubMed

    Günther-Leopold, Ines; Wernli, Beat; Kopajtic, Zlatko; Günther, Detlef

    2004-01-01

    Precise and accurate isotope ratio measurements are an important task in many applications such as isotope-dilution mass spectrometry, bioavailability studies, or the determination of isotope variations in geological or nuclear samples. The technique of MC-ICP-MS has attracted much attention because it permits the precise measurement of isotope compositions for a wide range of elements combined with excellent detection limits due to high ionisation efficiencies. However, the results are based mainly on measurements using continuous sample introduction. In the present study the determination of isotope ratios on various transient signals with a time duration of 30 to 60 s has been achieved by coupling high-performance liquid chromatography to a multicollector inductively coupled plasma mass spectrometer. In order to investigate the origin of ratio drifts across the transient signals for this hyphenated technique, measurements with the same standard solutions were also carried out using a flow-injection device for sample introduction. As a result of this application it could be concluded that the main source of the bias in the measured isotope ratios is within the ICP-MS instead of fractionation effects on the chromatographic column material. Preliminary studies on short transient signals of gaseous samples (dry plasma) showed a reverse fractionation effect compared with wet plasma conditions (flow injection and HPLC).

  13. Determination of 241Am in sediments by isotope dilution high resolution inductively coupled plasma mass spectrometry (ID HR ICP-MS).

    PubMed

    Agarande, M; Benzoubir, S; Bouisset, P; Calmet, D

    2001-08-01

    Trace levels (pg kg(-1)) of 241Am in sediments were determined by isotope dilution high resolution inductively coupled plasma mass spectrometry (ID HR ICP-MS) using a microconcentric nebulizer. 241Am was isolated from major elements like Ca and Fe by different selective precipitations. In further steps. Am was first separated from other transuranic elements and purified by anion exchange and extraction chromatography prior to the mass spectrometric measurements. The ID HR ICP-MS results are compared with isotope dilution alpha spectrometry.

  14. Quantitative Analysis by Isotopic Dilution Using Mass Spectroscopy: The Determination of Caffeine by GC-MS.

    ERIC Educational Resources Information Center

    Hill, Devon W.; And Others

    1988-01-01

    Describes a laboratory technique for quantitative analysis of caffeine by an isotopic dilution method for coupled gas chromatography-mass spectroscopy. Discusses caffeine analysis and experimental methodology. Lists sample caffeine concentrations found in common products. (MVL)

  15. Congener-specific determination of ultratrace levels of chlorinated and brominated polycyclic aromatic hydrocarbons in atmosphere and industrial stack gas by isotopic dilution gas chromatography/high resolution mass spectrometry method.

    PubMed

    Jin, Rong; Liu, Guorui; Zheng, Minghui; Fiedler, Heidelore; Jiang, Xiaoxu; Yang, Lili; Wu, Xiaolin; Xu, Yang

    2017-08-04

    Isotopic dilution gas chromatography combined with high resolution mass spectrometry (GC/HRMS) has overwhelming advantages with respect to the accuracy of congener-specific ultratrace analysis of complex persistent organic pollutants (POPs) in environmental matrices. However, an isotopic dilution GC/HRMS method for analysis of chlorinated and brominated polycyclic aromatic hydrocarbons (Cl-PAHs and Br-PAHs) using 13 C-labelled congeners as internal standards has not been established. In this study, a method for identification and quantification of 38 congeners of Cl-PAHs and Br-PAHs in atmosphere and stack gas samples from waste incinerators was developed using the isotopic dilution GC/HRMS technique. The instrumental detection limits of the GC/HRMS method ranged from 0.2pg to 1.8pg for Cl-PAH congeners, and 0.7pg to 2.7pg for Br-PAH congeners, which were about three orders of magnitude lower than those of the GC/quadrupole MS method. This new method developed was also the first to enable determination of Cl-PAH and Br-PAH homologs comprising congeners with the same molecular skeleton and chlorine or bromine substitution numbers. Among the detected congeners, seven Cl-PAH congeners and thirteen Br-PAH congeners that were abundant in the atmosphere and stack gases released from waste incinerators were firstly detected in real samples and reported using the established isotopic dilution GC/HRMS method. The developed isotopic dilution GC/HRMS is significant and needed for better studying the environmental behavior and health risk of Cl-PAHs and Br-PAHs. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Short communication: milk output in llamas (Lama glama) in relation to energy intake and water turnover measured by an isotope dilution technique.

    PubMed

    Riek, A; Klinkert, A; Gerken, M; Hummel, J; Moors, E; Südekum, K-H

    2013-03-01

    Despite the fact that llamas have become increasingly popular as companion and farm animals in both Europe and North America, scientific knowledge on their nutrient requirements is scarce. Compared with other livestock species, relatively little is known especially about the nutrient and energy requirements for lactating llamas. Therefore, we aimed to measure milk output in llama dams using an isotope dilution technique and relate it to energy intakes at different stages of lactation. We also validated the dilution technique by measuring total water turnover (TWT) directly and comparing it with values estimated by the isotope dilution technique. Our study involved 5 lactating llama dams and their suckling young. Milk output and TWT were measured at 4 stages of lactation (wk 3, 10, 18, and 26 postpartum). The method involved the application of the stable hydrogen isotope deuterium ((2)H) to the lactating dam. Drinking water intake and TWT decreased significantly with lactation stage, whether estimated by the isotope dilution technique or calculated from drinking water and water ingested from feeds. In contrast, lactation stage had no effect on dry matter intake, metabolizable energy (ME) intake, or the milk water fraction (i.e., the ratio between milk water excreted and TWT). The ratios between TWT measured and TWT estimated (by isotope dilution) did not differ with lactation stage and were close to 100% in all measurement weeks, indicating that the D(2)O dilution technique estimated TWT with high accuracy and only small variations. Calculating the required ME intakes for lactation from milk output data and gross energy content of milk revealed that, with increasing lactation stage, ME requirements per day for lactation decreased but remained constant per kilogram of milk output. Total measured ME intakes at different stages of lactation were similar to calculated ME intakes from published recommendation models for llamas. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Application of isotope dilution inductively coupled plasma mass spectrometry to the analysis of marine sediments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McLaren, J.W.; Beauchemin, D.; Berman, S.S.

    1987-02-15

    Isotope dilution inductively coupled plasma mass spectrometry (ICP-MS) has been applied to the determination of 11 trace elements (Cr, Ni, Zn, Sr, Mo, Cd, Sn, Sb, Tl, Pb, and U) in the marine sediment reference materials MESS-1 and BCSS-1. Accuracy and, especially, precision are better than those that can be easily achieved by other ICP-MS calibration strategies, as long as isotopic equilibration is achieved and the isotopes used for the ratio measurement are free of isobaric interferences by molecular species. The measurement of the isotope ratios on unspiked samples provides a sensitive diagnostic of such interferences.

  18. STATISTICAL ESTIMATES OF VARIANCE FOR 15N ISOTOPE DILUTION MEASUREMENTS OF GROSS RATES OF NITROGEN CYCLE PROCESSES

    EPA Science Inventory

    It has been fifty years since Kirkham and Bartholmew (1954) presented the conceptual framework and derived the mathematical equations that formed the basis of the now commonly employed method of 15N isotope dilution. Although many advances in methodology and analysis have been ma...

  19. Application of isotope dilution technique in vitamin A nutrition.

    PubMed

    Wasantwisut, Emorn

    2002-09-01

    The isotope dilution technique involving deuterated retinol has been developed to quantitatively estimate total body reserves of vitamin A in humans. The technique provided good estimates in comparison to hepatic vitamin A concentrations in Bangladeshi surgical patients. Kinetic studies in the United States, Bangladesh, and Guatemala indicated the mean equilibration time of 17 to 20 days irrespective of the size of hepatic reserves. Due to the controversy surrounding the efficacy of a carotene-rich diet on improvement of vitamin A status, the isotope dilution technique was proposed to pursue this research question further (IAEA's coordinated research program). In the Philippines, schoolchildren with low serum retinol concentrations showed significant improvement in total body vitamin A stores following intake of carotene-rich foods (orange fruits and vegetables), using a three-day deuterated-retinol-dilution procedure. When Chinese kindergarten children were fed green and yellow vegetables during the winter, their total body vitamin A stores were sustained as compared to a steady decline of vitamin A stores in the control children. Likewise, daily consumption of purified beta-carotene or diet rich in provitamin A carotenoids were shown to prevent a loss in total body vitamin A stores among Thai lactating women during the rice-planting season. These studies demonstrate potentials of the isotope dilution technique to evaluate the impact of provitamin A carotenoid intervention programs.

  20. High accuracy method for the application of isotope dilution to gas chromatography/mass spectrometric analysis of gases.

    PubMed

    Milton, Martin J T; Wang, Jian

    2003-01-01

    A new isotope dilution mass spectrometry (IDMS) method for high-accuracy quantitative analysis of gases has been developed and validated by the analysis of standard mixtures of carbon dioxide in nitrogen. The method does not require certified isotopic reference materials and does not require direct measurements of the highly enriched spike. The relative uncertainty of the method is shown to be 0.2%. Reproduced with the permission of Her Majesty's Stationery Office. Copyright Crown copyright 2003.

  1. Theoretical implications for the estimation of dinitrogen fixation by large perennial plant species using isotope dilution

    Treesearch

    Dwight D. Baker; Maurice Fried; John A. Parrotta

    1995-01-01

    Estimation of symbiotic N2 fixation associated with large perennial plant species, especially trees, poses special problems because the process must be followed over a potentially long period of time to integrate the total amount of fixation. Estimations using isotope dilution methodology have begun to be used for trees in field studies. Because...

  2. Evaluation of sulfur isotopic enrichment of urine metabolites for the differentiation of healthy and prostate cancer mice after the administration of 34S labelled yeast.

    PubMed

    Galilea San Blas, Oscar; Moreno Sanz, Fernando; Herrero Espílez, Pilar; Sainz Menéndez, Rosa María; Mayo Barallo, Juan Carlos; Marchante-Gayón, Juan Manuel; García Alonso, José Ignacio

    2017-01-01

    Sulfur isotopic enrichment of urine metabolites in healthy and prostate cancer mice using 34 S enriched yeast and High Performance Liquid Chromatography coupled to Multicollector Inductively Coupled Plasma Mass Spectrometry (HPLC-MC-ICP-MS) has been evaluated. A 30 weeks experiment (since the eleventh to the fortieth week of life) was carried out collecting the urine of three healthy mice and three transgenic mice with prostate cancer during 24h after a single oral administration of a 34 S enriched yeast slurry. The isotopic enrichment of different sulphur metabolites was monitored by coupling a C18 reverse phase HPLC column with a multicollector ICP-MS using a membrane desolvating system. Quantification of sulfur in the chromatographic peaks was carried out by post-column isotope dilution using a 33 S enriched spike. Differences between the 34 S enrichment in the urine metabolites of healthy and prostate cancer mice were found from the beginning of the disease. Both populations could be differentiated using a principal component analysis (PCA). Finally, 7 unknown mice were correctly classified in each population using a linear discriminant analysis. Copyright © 2016 Elsevier GmbH. All rights reserved.

  3. Microwave-assisted deuterium exchange: the convenient preparation of isotopically labelled analogues for stable isotope dilution analysis of volatile wine phenols.

    PubMed

    Crump, Anna M; Sefton, Mark A; Wilkinson, Kerry L

    2014-11-01

    This study reports the convenient, low cost, one-step synthesis of labelled analogues of six volatile phenols, guaiacol, 4-methylguaiacol, 4-ethylguaiacol, 4-ethylphenol, eugenol and vanillin, using microwave-assisted deuterium exchange, for use as internal standards for stable isotope dilution analysis. The current method improves on previous strategies in that it enables incorporation of deuterium atoms on the aromatic ring, thereby ensuring retention of the isotope label during mass spectrometry fragmentation. When used as standards for SIDA, these labelled volatile phenols will improve the accuracy and reproducibility of quantitative food and beverage analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Simultaneous determination of creatinine and creatine in human serum by double-spike isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS).

    PubMed

    Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio

    2015-04-07

    This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors derived from the sample preparation step.

  5. Chemical Warfare Agent Operational Exposure Hazard Assessment Research: FY07 Report and Analysis

    DTIC Science & Technology

    2010-07-01

    of the nerve agents sarin, soman, cyclohexylsarin, VX, and Russian VX in human urine using isotope-dilution gas chromatography-tandem mass...Needham L.L.; Barr, D.B. Quantitation of organophosphorous nerve agent metabolites in human urine using isotope dilution gas chromatography-tandem mass... nerve agents , VX, GB, or GF, and to determine lethal percutaneous (PC) levels of VX. Calibration of Physiologically-based pharmacokinetic biomarkers

  6. Comparison of Dilution, Filtration, and Microwave Digestion Sample Pretreatments in Elemental Profiling of Wine by ICP-MS.

    PubMed

    Godshaw, Joshua; Hopfer, Helene; Nelson, Jenny; Ebeler, Susan E

    2017-09-25

    Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the 63 Cu: 65 Cu instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.

  7. Direct determination of halogens in powdered geological and environmental samples using isotope dilution laser ablation ICP-MS

    NASA Astrophysics Data System (ADS)

    Boulyga, Sergei F.; Heumann, Klaus G.

    2005-04-01

    Laser ablation inductively coupled plasma isotope dilution mass spectrometry (LA-ICP-IDMS) with a special laser ablation system for bulk analyses (LINA-Spark(TM)-Atomiser) was applied for direct determinations of chlorine, bromine, and iodine in rock and sediment samples. Special attention was focused on possible inter-halogen fractionations and analyte/spike isotope fractionations by using LA-ICP-MS and LA-ICP-IDMS, respectively. A variation of Br/Cl and I/Cl element intensity ratios by a factor of 1.3-3 was observed when changing the nebulizer gas flow rate in the range of 0.84-1.0 L min-1 and the laser power density in the range of 2-10 GW cm-2, respectively. When using an internal standard for halogen quantification in LA-ICP-MS, this inter-element fractionation can cause systematic errors, which can be avoided by applying the isotope dilution technique. However, at high laser power densities (>5.7 GW cm-2 for iodine and >4.0 GW cm-2 for bromine and chlorine) the corresponding measured isotope ratio of the isotope-diluted sample deviates significantly from the target value. Under optimised conditions concentrations in the range of 30 [mu]g g-1-16 × 103 [mu]g g-1 for chlorine, <2-140 [mu]g g-1 for bromine, and <0.1-31 [mu]g g-1 for iodine were determined by LA-ICP-IDMS in two sediment reference materials (SRM 1646, SRM 2704) and three rock reference samples (GS-N, Granite; BX-N, Bauxite; DT-N, Disthene), which have not been certified for these halogens. The sediment results agree well within the given uncertainties with indicative values by different methods and the results of the rock samples with those obtained by negative thermal ionisation isotope dilution mass spectrometry. The detection limits of LA-ICP-IDMS are 8 [mu]g g-1 for chlorine, 1.7 [mu]g g-1 for bromine, and 0.1 [mu]g g-1 for iodine.

  8. Guideline on Isotope Dilution Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaffney, Amy

    Isotope dilution mass spectrometry is used to determine the concentration of an element of interest in a bulk sample. It is a destructive analysis technique that is applicable to a wide range of analytes and bulk sample types. With this method, a known amount of a rare isotope, or ‘spike’, of the element of interest is added to a known amount of sample. The element of interest is chemically purified from the bulk sample, the isotope ratio of the spiked sample is measured by mass spectrometry, and the concentration of the element of interest is calculated from this result. Thismore » method is widely used, although a mass spectrometer required for this analysis may be fairly expensive.« less

  9. Determination of cadmium in sediments by diluted HCI extraction and isotope dilution ICP-MS.

    PubMed

    Terán-Baamonde, Javier; Soto-Ferreiro, Rosa-María; Carlosena, Alatzne; Andrade, José-Manuel; Prada, Darío

    2018-08-15

    Isotope dilution ICP-MS is proposed to measure the mass fraction of Cd extracted by diluted HCl in marine sediments, using a fast and simple extraction procedure based on ultrasonic probe agitation. The 111 Cd isotope was added before the extraction to achieve isotope equilibration with native Cd solubilized from the sample. The parameters affecting trueness and precision of isotope ratio measurements were evaluated carefully and subsequently corrected in order to minimize errors; they were: detector dead time, spectral interferences, mass discrimination factor and optimum sample/spike ratio. The mass fraction of Cd extracted was compared with the sum of the certified contents of the three steps of the sequential extraction procedure of the Standards, Measurements and Testing Programme (SM&T) analysing the BCR 701 sediment to validate the method. The certified and measured values agreed, giving a measured / certified mass fraction ratio of 1.05. Further, the extraction procedure itself was studied by adding the enriched isotope after the extraction step, which allowed verifying that analyte losses occurred during this process. Two additional reference sediments with certified total cadmium contents were also analysed. The method provided very good precision (0.9%, RSD) and a low detection limit, 1.8 ng g -1 . The procedural uncertainty budget was estimated following the EURACHEM Guide by means of the 'GUM Workbench' software, obtaining a relative expanded uncertainty of 1.5%. The procedure was applied to determine the bioaccessible mass fraction of Cd in sediments from two environmentally and economically important areas of Galicia (rias of Arousa and Vigo, NW of Spain). Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Determination of copper by isotopic dilution.

    PubMed

    Faquim, E S; Munita, C S

    1994-01-01

    A rapid and selective method was used for the determination of copper by isotopic dilution employing substoichiometric extraction with dithizone in carbon tetrachloride. The appropriate pH range for the substoichiometric extraction was 2-7. In the analysis, even a large excess of elements forming extractable complexes with dithizone does not interfere. The accuracy and precision of the method were evaluated. The method has been applied to analysis of reference materials, wheat flour, wine, and beer.

  11. Determination of Glyphosate, its Degradation Product Aminomethylphosphonic Acid, and Glufosinate, in Water by Isotope Dilution and Online Solid-Phase Extraction and Liquid Chromatography/Tandem Mass Spectrometry

    USGS Publications Warehouse

    Meyer, Michael T.; Loftin, Keith A.; Lee, Edward A.; Hinshaw, Gary H.; Dietze, Julie E.; Scribner, Elisabeth A.

    2009-01-01

    The U.S. Geological Survey method (0-2141-09) presented is approved for the determination of glyphosate, its degradation product aminomethylphosphonic acid (AMPA), and glufosinate in water. It was was validated to demonstrate the method detection levels (MDL), compare isotope dilution to standard addition, and evaluate method and compound stability. The original method USGS analytical method 0-2136-01 was developed using liquid chromatography/mass spectrometry and quantitation by standard addition. Lower method detection levels and increased specificity were achieved in the modified method, 0-2141-09, by using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The use of isotope dilution for glyphosate and AMPA and pseudo isotope dilution of glufosinate in place of standard addition was evaluated. Stable-isotope labeled AMPA and glyphosate were used as the isotope dilution standards. In addition, the stability of glyphosate and AMPA was studied in raw filtered and derivatized water samples. The stable-isotope labeled glyphosate and AMPA standards were added to each water sample and the samples then derivatized with 9-fluorenylmethylchloroformate. After derivatization, samples were concentrated using automated online solid-phase extraction (SPE) followed by elution in-line with the LC mobile phase; the compounds separated and then were analyzed by LC/MS/MS using electrospray ionization in negative-ion mode with multiple-reaction monitoring. The deprotonated derivatized parent molecule and two daughter-ion transition pairs were identified and optimized for glyphosate, AMPA, glufosinate, and the glyphosate and AMPA stable-isotope labeled internal standards. Quantitative comparison between standard addition and isotope dilution was conducted using 473 samples analyzed between April 2004 and June 2006. The mean percent difference and relative standard deviation between the two quantitation methods was 7.6 plus or minus 6.30 (n = 179), AMPA 9.6 plus or minus 8.35 (n = 206), and glufosinate 9.3 plus or minus 9.16 (n = 16). The analytical variation of the method, comparison of quantitation by isotope dilution and multipoint linear regressed standard curves, and method detection levels were evaluated by analyzing six sets of distilled-water, groundwater, and surface-water samples spiked in duplicate at 0.0, 0.05, 0.10 and 0.50 microgram per liter and analyzed on 6 different days during 1 month. The grand means of the normalized concentration percentage recovery for glyphosate, AMPA, and glufosinate among all three matrices and spiked concentrations ranged from 99 to 114 plus or minus 2 to 7 percent of the expected spiked concentration. The grand mean of the percentage difference between concentrations calculated by standard addition and linear regressed multipoint standard curves ranged from 8 to 15 plus or minus 2 to 9 percent for the three compounds. The method reporting levels calculated from all the 0.05- microgram per liter spiked samples were 0.02 microgram per liter for all three compounds. Compound stability experiments were conducted on 10 samples derivatized four times for periods between 136 to 269 days. The glyphosate and AMPA concentrations remained relatively constant in samples held up to 136 days before derivatization. The half life of glyphosate varied from 169 to 223 days in the underivatized samples. Derivatized samples were analyzed the day after derivitization, and again 54 and 64 days after derivatization. The derivatized samples analyzed at days 52 and 64 were within 20 percent of the concentrations of the derivatized samples analyzed the day after derivatization.

  12. Method to make accurate concentration and isotopic measurements for small gas samples

    NASA Astrophysics Data System (ADS)

    Palmer, M. R.; Wahl, E.; Cunningham, K. L.

    2013-12-01

    Carbon isotopic ratio measurements of CO2 and CH4 provide valuable insight into carbon cycle processes. However, many of these studies, like soil gas, soil flux, and water head space experiments, provide very small gas sample volumes, too small for direct measurement by current constant-flow Cavity Ring-Down (CRDS) isotopic analyzers. Previously, we addressed this issue by developing a sample introduction module which enabled the isotopic ratio measurement of 40ml samples or smaller. However, the system, called the Small Sample Isotope Module (SSIM), does dilute the sample during the delivery with inert carrier gas which causes a ~5% reduction in concentration. The isotopic ratio measurements are not affected by this small dilution, but researchers are naturally interested accurate concentration measurements. We present the accuracy and precision of a new method of using this delivery module which we call 'double injection.' Two portions of the 40ml of the sample (20ml each) are introduced to the analyzer, the first injection of which flushes out the diluting gas and the second injection is measured. The accuracy of this new method is demonstrated by comparing the concentration and isotopic ratio measurements for a gas sampled directly and that same gas measured through the SSIM. The data show that the CO2 concentration measurements were the same within instrument precision. The isotopic ratio precision (1σ) of repeated measurements was 0.16 permil for CO2 and 1.15 permil for CH4 at ambient concentrations. This new method provides a significant enhancement in the information provided by small samples.

  13. Measurement of isotope abundance variations in nature by gravimetric spiking isotope dilution analysis (GS-IDA).

    PubMed

    Chew, Gina; Walczyk, Thomas

    2013-04-02

    Subtle variations in the isotopic composition of elements carry unique information about physical and chemical processes in nature and are now exploited widely in diverse areas of research. Reliable measurement of natural isotope abundance variations is among the biggest challenges in inorganic mass spectrometry as they are highly sensitive to methodological bias. For decades, double spiking of the sample with a mix of two stable isotopes has been considered the reference technique for measuring such variations both by multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS) and multicollector-thermal ionization mass spectrometry (MC-TIMS). However, this technique can only be applied to elements having at least four stable isotopes. Here we present a novel approach that requires measurement of three isotope signals only and which is more robust than the conventional double spiking technique. This became possible by gravimetric mixing of the sample with an isotopic spike in different proportions and by applying principles of isotope dilution for data analysis (GS-IDA). The potential and principle use of the technique is demonstrated for Mg in human urine using MC-TIMS for isotopic analysis. Mg is an element inaccessible to double spiking methods as it consists of three stable isotopes only and shows great potential for metabolically induced isotope effects waiting to be explored.

  14. A direct evidence of vibrationally delocalized response at ice surface.

    PubMed

    Ishiyama, Tatsuya; Morita, Akihiro

    2014-11-14

    Surface-specific vibrational spectroscopic responses at isotope diluted ice and amorphous ice are investigated by molecular dynamics (MD) simulations combined with quantum mechanics/molecular mechanics calculations. The intense response specific to the ordinary crystal ice surface is predicted to be significantly suppressed in the isotopically diluted and amorphous ices, demonstrating the vibrational delocalization at the ordinary ice surface. The collective vibration at the ice surface is also analyzed with varying temperature by the MD simulation.

  15. Stable isotope dilution microquantification of creatine metabolites in plasma, whole blood and dried blood spots for pharmacological studies in mouse models of creatine deficiency.

    PubMed

    Tran, C; Yazdanpanah, M; Kyriakopoulou, L; Levandovskiy, V; Zahid, H; Naufer, A; Isbrandt, D; Schulze, A

    2014-09-25

    To develop an accurate stable isotope dilution assay for simultaneous quantification of creatine metabolites ornithine, arginine, creatine, creatinine, and guanidinoacetate in very small blood sample volumes to study creatine metabolism in mice. Liquid-chromatography (C18) tandem mass spectrometry with butylation was performed in positive ionization mode. Stable isotope dilution assay with external calibration was applied to three different specimen types, plasma, whole blood and dried blood spot (DBS). Analytical separation, sensitivity, accuracy, and linearity of the assay were adequate. The stable isotope dilution assay in plasma revealed no significant bias to gold standard methods for the respective analytes. Compared to plasma, we observed an overestimate of creatine and creatinine (2- to 5-fold and 1.2- to 2-fold, respectively) in whole-blood and DBS, and an underestimate of arginine (2.5-fold) in DBS. Validation of the assay in mouse models of creatine deficiency revealed plasma creatine metabolite pattern in good accordance with those observed in human GAMT and AGAT deficiency. Single dose intraperitoneal application of ornithine in wild-type mice lead to fast ornithine uptake (Tmax ≤ 10 min) and elimination (T1/2=24 min), and a decline of guanidinoacetate. The assay is fast and reliable to study creatine metabolism and pharmacokinetics in mouse models of creatine deficiency. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Separation processes using expulsion from dilute supercritical solutions

    DOEpatents

    Cochran, Jr., Henry D.

    1993-01-01

    A process for separating isotopes as well as other mixtures by utilizing the behavior of dilute repulsive or weakly attractive elements of the mixtures as the critical point of the solvent is approached.

  17. Simultaneous determination of the quantity and isotopic ratios of uranium in individual micro-particles by isotope dilution thermal ionization mass spectrometry (ID-TIMS).

    PubMed

    Park, Jong-Ho; Choi, Eun-Ju

    2016-11-01

    A method to determine the quantity and isotopic ratios of uranium in individual micro-particles simultaneously by isotope dilution thermal ionization mass spectrometry (ID-TIMS) has been developed. This method consists of sequential sample and spike loading, ID-TIMS for isotopic measurement, and application of a series of mathematical procedures to remove the contribution of uranium in the spike. The homogeneity of evaporation and ionization of uranium content was confirmed by the consistent ratio of n((233)U)/n((238)U) determined by TIMS measurements. Verification of the method was performed using U030 solution droplets and U030 particles. Good agreements of resulting uranium quantity, n((235)U)/n((238)U), and n((236)U)/n((238)U) with the estimated or certified values showed the validity of this newly developed method for particle analysis when simultaneous determination of the quantity and isotopic ratios of uranium is required. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Quantitation of Rotundone in Grapefruit (Citrus paradisi) Peel and Juice by Stable Isotope Dilution Assay.

    PubMed

    Nakanishi, Akira; Fukushima, Yusuke; Miyazawa, Norio; Yoshikawa, Keisuke; Maeda, Tomoko; Kurobayashi, Yoshiko

    2017-06-21

    Aroma extract dilution analyses of the aromas of peels and juices of white and pink grapefruits revealed that rotundone, responsible for peppery, spicy, and woody odors, was detected for the first time at high flavor dilution factors of 256-1024. In both juices, rotundone was detected at the highest flavor dilution factor of 1024. Rotundone in grapefruits was quantitated by a stable isotope dilution assay with a newly synthesized deuterium-labeled internal standard, rotundone-d 2,3 : its levels were 2180 and 1920 ng/kg in white and pink grapefruit peels and 29.6 and 49.8 ng/kg in white and pink grapefruit juices, respectively. On the basis of these results, sensory analysis was performed to assess the effects of rotundone on a white grapefruit juice aroma reconstitute. This sensory analysis revealed that rotundone does not impart a woody odor or affect any of the existing attributes, but increases various attributes, thus confirming that rotundone is indispensable for the aroma of grapefruit juice.

  19. Separation processes using expulsion from dilute supercritical solutions

    DOEpatents

    Cochran, H.D. Jr.

    1993-04-20

    A process is described for separating isotopes as well as other mixtures by utilizing the behavior of dilute repulsive or weakly attractive elements of the mixtures as the critical point of the solvent is approached.

  20. Carbon and hydrogen isotopic reversals in deep basin gas: Evidence for limits to the stability of hydrocarbons

    USGS Publications Warehouse

    Burruss, R.C.; Laughrey, C.D.

    2010-01-01

    During studies of unconventional natural gas reservoirs of Silurian and Ordovician age in the northern Appalachian basin we observed complete reversal of the normal trend of carbon isotopic composition, such that ??13C methane (C1) >??13C ethane (C2) >??13C propane (C3). In addition, we have observed isotopic reversals in the ??2H in the deepest samples. Isotopic reversals cannot be explained by current models of hydrocarbon gas generation. Previous observations of partial isotopic reversals have been explained by mixing between gases from different sources and thermal maturities. We have constructed a model which, in addition to mixing, requires Rayleigh fractionation of C2 and C3 to cause enrichment in 13C and create reversals. In the deepest samples, the normal trend of increasing enrichment of 13C and 2H in methane with increasing depth reverses and 2H becomes depleted as 13C becomes enriched. We propose that the reactions that drive Rayleigh fractionation of C2 and C3 involve redox reactions with transition metals and water at late stages of catagenesis at temperatures on the order of 250-300??C. Published ab initio calculated fractionation factors for C-C bond breaking in ethane at these temperatures are consistent with our observations. The reversed trend in ??2H in methane appears to be caused by isotopic exchange with formation water at the same temperatures. Our interpretation that Rayleigh fractionation during redox reactions is causing isotopic reversals has important implications for natural gas resources in deeply buried sedimentary basins. ?? 2010.

  1. Determination of uranium and thorium in materials associated with real time electronic solar neutrino detectors

    NASA Astrophysics Data System (ADS)

    Fassett, J. D.; Kelly, W. R.

    1992-07-01

    The application of isotope dilution thermal ionization mass spectrometry to the determination of both uranium and thorium in four different target materials used or proposed for electronic neutrino detectors is described. Isotope dilution analysis is done using highly enriched 233U and 230Th separated isotopes. Sensitivity of the technique is such that sub-picogram amounts of material are readily measured. The overall limit to measurement is caused by contamination of these elements during the measurement process. Uranium is more easily measured than thorium because both the instrumental sensitivity is higher and contamination is better controlled. The materials analyzed were light and heavy water, pseudocumene, and mineral oil.

  2. Deuterium dilution technique for body composition assessment: resolving methodological issues in children with moderate acute malnutrition.

    PubMed

    Fabiansen, Christian; Yaméogo, Charles W; Devi, Sarita; Friis, Henrik; Kurpad, Anura; Wells, Jonathan C

    2017-08-01

    Childhood malnutrition is highly prevalent and associated with high mortality risk. In observational and interventional studies among malnourished children, body composition is increasingly recognised as a key outcome. The deuterium dilution technique has generated high-quality data on body composition in studies of infants and young children in several settings, but its feasibility and accuracy in children suffering from moderate acute malnutrition requires further study. Prior to a large nutritional intervention trial among children with moderate acute malnutrition, we conducted pilot work to develop and adapt the deuterium dilution technique. We refined procedures for administration of isotope doses and collection of saliva. Furthermore, we established that equilibration time in local context is 3 h. These findings and the resulting standard operating procedures are important to improve data quality when using the deuterium dilution technique in malnutrition studies in field conditions, and may encourage a wider use of isotope techniques.

  3. Production of highly-enriched 134Ba for a reference material for isotope dilution mass spectrometry measurements

    DOE PAGES

    Horkley, J. J.; Carney, K. P.; Gantz, E. M.; ...

    2015-03-17

    Isotope dilution mass spectrometry (IDMS) is an analytical technique capable of providing accurate and precise quantitation of trace isotope abundance and assay providing measurement uncertainties below 1 %. To achieve these low uncertainties, the IDMS method ideally utilizes chemically pure “spike” solutions that consist of a single highly enriched isotope that is well-characterized relating to the abundance of companion isotopes and concentration in solution. To address a current demand for accurate 137Cs/137Ba ratio measurements for “age” determination of radioactive 137Cs sources, Idaho National Laboratory (INL) is producing enriched 134Ba isotopes that are tobe used for IDMS spikes to accurately determinemore » 137Ba accumulation from the decay of 137Cs. The final objective of this work it to provide a homogenous set of reference materials that the National Institute of Standards and Technology can certify as standard reference materials used for IDMS. The process that was developed at INL for the separation and isolation of Ba isotopes, chemical purification of the isotopes in solution, and the encapsulation of the materials will be described.« less

  4. A novel technique to determine cobalt exchangeability in soils using isotope dilution.

    PubMed

    Wendling, Laura A; Kirby, Jason K; McLaughlin, Michael J

    2008-01-01

    The environmental risk posed by Co contamination is largely a function of its oxidation state. Our objective was to assess the potential biological availability of Co and the reactions and fate of soluble Co(II) after addition to soils with varying physical and chemical characteristics. A potential risk in quantifying exchangeable Co in soils using isotope dilution techniques is the possible presence of two species of Co in soil solution and adsorbed on soil solid phases [Co(II) and Co(III)], coupled with the possibility that when an isotope of Co is added it may undergo a change in oxidation state during the measurement phase. In this study, we have utilized an isotope dilution technique with cation exchange and high-performance liquid chromatography-inductively coupled plasma-mass spectrometry to determine the isotopically exchangeable Co fraction in several soils with varying characteristics such as differing Al, Fe, and Mn oxide content; pH; and organic carbon content. The application of the cation exchange procedure adjusts measurements of isotopically exchangeable Co to correct for the presence of non-exchangeable 57Co not in equilibrium with the solution phase. Results indicated that oxidation of added 57Co(II) to 57Co(III) or precipitation of 57Co(II) may occur on the surfaces of some soils, particularly those with a high pH or substantial quantities of Mn oxide minerals. No detectable Co(III)(aq) was found in the aqueous extracts of the soils examined.

  5. Isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS) for the certification of lead and cadmium in environmental standard reference materials.

    PubMed

    Murphy, K E; Beary, E S; Rearick, M S; Vocke, R D

    2000-10-01

    Lead (Pb) and cadmium (Cd) have been determined in six new environmental standard reference materials (SRMs) using isotope dilution inductively coupled plasma mass spectrometry (ID ICP-MS). The SRMs are the following: SRM 1944, New York-New Jersey Waterway Sediment, SRMs 2583 and 2584, Trace Elements in Indoor Dust, Nominal 90 mg/kg and 10,000 mg/kg Lead, respectively, SRMs 2586 and 2587, Trace Elements in Soil Containing Lead from Paint, Nominal 500 mg/kg and 3,000 mg/kg Lead, respectively, and SRM 2782, Industrial Sludge. The capabilities of ID ICP-MS for the certification of Pb and Cd in these materials are assessed. Sample preparation and ratio measurement uncertainties have been evaluated. Reproducibility and accuracy of the established procedures are demonstrated by determination of gravimetrically prepared primary standard solutions and by comparison with isotope dilution thermal ionization mass spectrometry (ID TIMS). Material heterogeneity was readily demonstrated to be the dominant source of uncertainty in the certified values.

  6. Representative Atmospheric Plume Development for Elevated Releases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eslinger, Paul W.; Lowrey, Justin D.; McIntyre, Justin I.

    2014-02-01

    An atmospheric explosion of a low-yield nuclear device will produce a large number of radioactive isotopes, some of which can be measured with airborne detection systems. However, properly equipped aircraft may not arrive in the region where an explosion occurred for a number of hours after the event. Atmospheric conditions will have caused the radioactive plume to move and diffuse before the aircraft arrives. The science behind predicting atmospheric plume movement has advanced enough that the location of the maximum concentrations in the plume can be determined reasonably accurately in real time, or near real time. Given the assumption thatmore » an aircraft can follow a plume, this study addresses the amount of atmospheric dilution expected to occur in a representative plume as a function of time past the release event. The approach models atmospheric transport of hypothetical releases from a single location for every day in a year using the publically available HYSPLIT code. The effective dilution factors for the point of maximum concentration in an elevated plume based on a release of a non-decaying, non-depositing tracer can vary by orders of magnitude depending on the day of the release, even for the same number of hours after the release event. However, the median of the dilution factors based on releases for 365 consecutive days at one site follows a power law relationship in time, as shown in Figure S-1. The relationship is good enough to provide a general rule of thumb for estimating typical future dilution factors in a plume starting at the same point. However, the coefficients of the power law function may vary for different release point locations. Radioactive decay causes the effective dilution factors to decrease more quickly with the time past the release event than the dilution factors based on a non-decaying tracer. An analytical expression for the dilution factors of isotopes with different half-lives can be developed given the power law expression for the non-decaying tracer. If the power-law equation for the median dilution factor, Df, based on a non-decaying tracer has the general form Df=a(×t)^(-b) for time t after the release event, then the equation has the form Df=e^(-λt)×a×t^(-b) for a radioactive isotope, where λ is the decay constant for the isotope.« less

  7. Highly enriched multiply-labeled stable isotopic compounds as atmospheric tracers

    DOEpatents

    Goldblatt, M.; McInteer, B.B.

    1974-01-29

    Compounds multiply-labeled with stable isotopes and highly enriched in these isotopes are readily capable of detection in tracer experiments involving high dilutions. Thus, for example, /sup 13/C/sup 18/O/sub 2/ provides a useful tracer for following atmospheric pol lution produced as a result of fossil fuel burning. (Official Gazette)

  8. Reduction of Solvent Effect in Reverse Phase Gradient Elution LC-ICP-MS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sullivan, Patrick Allen

    2005-12-17

    Quantification in liquid chromatography (LC) is becoming very important as more researchers are using LC, not as an analytical tool itself, but as a sample introduction system for other analytical instruments. The ability of LC instrumentation to quickly separate a wide variety of compounds makes it ideal for analysis of complex mixtures. For elemental speciation, LC is joined with inductively coupled plasma mass spectrometry (ICP-MS) to separate and detect metal-containing, organic compounds in complex mixtures, such as biological samples. Often, the solvent gradients required to perform complex separations will cause matrix effects within the plasma. This limits the sensitivity ofmore » the ICP-MS and the quantification methods available for use in such analyses. Traditionally, isotope dilution has been the method of choice for LC-ICP-MS quantification. The use of naturally abundant isotopes of a single element in quantification corrects for most of the effects that LC solvent gradients produce within the plasma. However, not all elements of interest in speciation studies have multiple naturally occurring isotopes; and polyatomic interferences for a given isotope can develop within the plasma, depending on the solvent matrix. This is the case for reverse phase LC separations, where increasing amounts of organic solvent are required. For such separations, an alternative to isotope dilution for quantification would be is needed. To this end, a new method was developed using the Apex-Q desolvation system (ESI, Omaha, NE) to couple LC instrumentation with an ICP-MS device. The desolvation power of the system allowed greater concentrations of methanol to be introduced to the plasma prior to destabilization than with direct methanol injection into the plasma. Studies were performed, using simulated and actual linear methanol gradients, to find analyte-internal standard (AIS) pairs whose ratio remains consistent (deviations {+-} 10%) over methanol concentration ranges of 5%-35% (simulated) and 8%-32% (actual). Quadrupole (low resolution) and sector field (high resolution) ICP-MS instrumentation were utilized in these studies. Once an AIS pair is determined, quantification studies can be performed. First, an analysis is performed by adding both elements of the AIS pair post-column while performing the gradient elution without sample injection. A comparison of the ratio of the measured intensities to the atomic ratio of the two standards is used to determine a correction factor that can be used to account for the matrix effects caused by the mobile phase. Then, organic and/or biological molecules containing one of the two elements in the AIS pair are injected into the LC column. A gradient method is used to vary the methanol-water mixture in the mobile phase and to separate out the compounds in a given sample. A standard solution of the second ion in the AIS pair is added continuously post-column. By comparing the ratio of the measured intensities to the atomic ratio of the eluting compound and internal standard, the concentration of the injected compound can be determined.« less

  9. Estrogens in seminal plasma of human and animal species: identification and quantitative estimation by gas chromatography-mass spectrometry associated with stable isotope dilution.

    PubMed

    Reiffsteck, A; Dehennin, L; Scholler, R

    1982-11-01

    Estrone, 2-methoxyestrone and estradiol-17 beta have been definitely identified in seminal plasma of man, bull, boar and stallion by high resolution gas chromatography associated with selective monitoring of characteristic ions of suitable derivatives. Quantitative estimations were performed by isotope dilution with deuterated analogues and by monitoring molecular ions of trimethylsilyl ethers of labelled and unlabelled compounds. Concentrations of unconjugated and total estrogens are reported together with the statistical evaluation of accuracy and precision.

  10. Trace determination of zinc by substoichiometric isotope dilution analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sandhya, D.; Priya, S.; Subramanian, M.O.S.

    1996-09-01

    A radiometric method based on substoichiometric isotope dilution analysis using 1,10-phenanthroline and a substoichiometric amount of eosin was developed for determining trace amounts of zinc. Evaluation of various metal ion interferences shows that as little as 0.2 {mu}g Zn could be determined in an aqueous-phase volume of 60 mL. The method has been successfully applied to the determination of Zn in city waste incineration ash, cadmium metal, Fourts-B tablets, Boro-plus ointment, and magnesium alloy samples. 12 refs., 3 figs., 3 tabs.

  11. Species specific isotope dilution for the accurate and SI traceable determination of arsenobetaine and methylmercury in cuttlefish and prawn.

    PubMed

    Kumkrong, Paramee; Thiensong, Benjaporn; Le, Phuong Mai; McRae, Garnet; Windust, Anthony; Deawtong, Suladda; Meija, Juris; Maxwell, Paulette; Yang, Lu; Mester, Zoltán

    2016-11-02

    Methods based on species specific isotope dilution were developed for the accurate and SI traceable determination of arsenobetaine (AsBet) and methylmercury (MeHg) in prawn and cuttlefish tissues by LC-MS/MS and SPME GC-ICPMS. Quantitation of AsBet and MeHg were achieved by using a 13 C-enriched AsBet spike (NRC CRM CBET-1) and an enriched spike of Me 198 Hg (NRC CRM EMMS-1), respectively, wherein analyte mass fractions in enriched spikes were determined by reverse isotope dilution using natural abundance AsBet and MeHg primary standards. Purity of these primary standards were characterized by quantitative 1 H-NMR with the use of NIST SRM 350b benzoic acid as a primary calibrator, ensuring the final measurement results traceable to SI. Validation of employed methods of ID LC-MS/MS and ID SPME GC-ICPMS was demonstrated by analysis of several biological CRMs (DORM-4, TORT-3, DOLT-5, BCR-627 and BCR-463) with satisfying results. The developed methods were applied for the determination of AsBet and MeHg in two new certified reference materials (CRMs) prawn (PRON-1) and cuttlefish (SQID-1) produced jointly by Thailand Institute of Scientific and Technological Research (TISTR) and National Research Council Canada (NRC). With additional measurements of AsBet using LC-ICPMS with standard additions calibration and external calibration at NRC and TISTR, respectively, certified values of 1.206 ± 0.058 and 13.96 ± 0.54 mg kg -1 for AsBet as As (expanded uncertainty, k = 2) were obtained for the new CRMs PRON-1 and SQID-1, respectively. The reference value of 0.324 ± 0.028 mg kg -1 as Hg (expanded uncertainty, k = 2) for MeHg was obtained for the SQID-1 based on the results obtained by ID SPME GC-ICPMS method only, whereas MeHg in PRON-1 was found to be < 0.015 mg kg -1 . It was found that AsBet comprised 69.7% and 99.0% of total As in the prawn and cuttlefish, respectively, whereas MeHg comprised 94.5% of total Hg in cuttlefish. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  12. The micro-scale synthesis of (117)Sn-enriched tributyltin chloride and its characterization by GC-ICP-MS and NMR techniques.

    PubMed

    Peeters, Kelly; Iskra, Jernej; Zuliani, Tea; Ščančar, Janez; Milačič, Radmila

    2014-07-01

    Organotin compounds (OTCs) are among the most toxic substances ever introduced to the environment by man. They are common pollutants in marine ecosystems, but are also present in the terrestrial environment, accumulated mainly in sewage sludge and landfill leachates. In investigations of the degradation and methylation processes of OTC in environmental samples, the use of enriched isotopic tracers represents a powerful analytical tool. Sn-enriched OTC are also necessary in application of the isotope dilution mass spectrometry technique for their accurate quantification. Since Sn-enriched monobutyltin (MBT), dibutyltin (DBT) and tributyltin (TBT) are not commercially available as single species, "in house" synthesis of individual butyltin-enriched species is necessary. In the present work, the preparation of the most toxic butyltin, namely TBT, was performed via a simple synthetic path, starting with bromination of metallic Sn, followed by butylation with butyl lithium. The tetrabutyltin (TeBT) formed was transformed to tributyltin chloride (TBTCl) using concentrated hydrochloric acid (HCl). The purity of the synthesized TBT was verified by speciation analysis using the techniques of gas chromatography coupled to inductively coupled plasma mass spectrometry (GC-ICP-MS) and nuclear magnetic resonance (NMR). The results showed that TBT had a purity of more than 97%. The remaining 3% corresponded to DBT. TBT was quantified by reverse isotope dilution GC-ICP-MS. The synthesis yield was around 60%. The advantage of this procedure over those previously reported lies in its possibility to be applied on a micro-scale (starting with 10mg of metallic Sn). This feature is of crucial importance, since enriched metallic Sn is extremely expensive. The procedure is simple and repeatable, and was successfully applied for the preparation of (117)Sn-enriched TBTCl from (117)Sn-enriched metal. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Quantitative Mass Spectrometry by Isotope Dilution and Multiple Reaction Monitoring (MRM).

    PubMed

    Russo, Paul; Hood, Brian L; Bateman, Nicholas W; Conrads, Thomas P

    2017-01-01

    Selected reaction monitoring (SRM) is used in molecular profiling to detect and quantify specific known proteins in complex mixtures. Using isotope dilution (Barnidge et al., Anal Chem 75(3):445-451, 2003) methodologies, peptides can be quantified without the need for an antibody-based method. Selected reaction monitoring assays employ electrospray ionization mass spectrometry (ESI-MS) followed by two stages of mass selection: a first stage where the mass of the peptide ion is selected and, after fragmentation by collision-induced dissociation (CID), a second stage (tandem MS) where either a single (e.g., SRM) or multiple (multiple reaction monitoring, MRM) specific peptide fragment ions are transmitted for detection. The MRM experiment is accomplished by specifying the parent masses of the selected endogenous and isotope-labeled peptides for MS/MS fragmentation and then monitoring fragment ions of interest, using their intensities/abundances and relative ratios to quantify the parent protein of interest. In this example protocol, we will utilize isotope dilution MRM-MS to quantify in absolute terms the total levels of the protein of interest, ataxia telangiectasia mutated (ATM) serine/threonine protein kinase. Ataxia telangiectasia mutated (ATM) phosphorylates several key proteins that initiate activation of the DNA damage checkpoint leading to cell cycle arrest.

  14. Determination of (187)Os in molybdenite by ICP-MS with neutron-induced (186)Os and (188)Os spikes.

    PubMed

    Qu, W; Du, A; Zhao, D

    2001-10-31

    The article describes a method for the determination of (187)Os in molybdenite by isotope dilution inductively coupled plasma-mass spectrometry (ID-ICP-MS) with neutron-induced (186)Os and (188)Os spike. The spike used in the present work was prepared in line with the principle by which artificial nuclides are produced in a nuclear reaction. The concentration and isotopic composition of osmium in the prepared spike were evaluated accurately with the isotope dilution method, using negative thermal ion mass spectrometry (N-TIMS). The advantage of this method is that using (186)Os and (188)Os double spikes can effectively compensate for the mass discrimination effects of ICP-MS. Thus, the common correction practice for mass bias in the isotope dilution method with a single spike is unnecessary. In addition, the method enables one to reduce the determined error arising from instrumental instability. The precision for the (187)Os/((186)Os+(188)Os) ratio was approximately 2% (2sigma, RSD), but in the case of (187)Os/(186)Os, (187)Os/(188)Os and (186)Os/(188)Os, precision ranged from 2.0 to 8% (2sigma, RSD). The results for (187)Os concentration in a molybdenite sample determined with this method showed good agreement with reference values.

  15. Target analyte quantification by isotope dilution LC-MS/MS directly referring to internal standard concentrations--validation for serum cortisol measurement.

    PubMed

    Maier, Barbara; Vogeser, Michael

    2013-04-01

    Isotope dilution LC-MS/MS methods used in the clinical laboratory typically involve multi-point external calibration in each analytical series. Our aim was to test the hypothesis that determination of target analyte concentrations directly derived from the relation of the target analyte peak area to the peak area of a corresponding stable isotope labelled internal standard compound [direct isotope dilution analysis (DIDA)] may be not inferior to conventional external calibration with respect to accuracy and reproducibility. Quality control samples and human serum pools were analysed in a comparative validation protocol for cortisol as an exemplary analyte by LC-MS/MS. Accuracy and reproducibility were compared between quantification either involving a six-point external calibration function, or a result calculation merely based on peak area ratios of unlabelled and labelled analyte. Both quantification approaches resulted in similar accuracy and reproducibility. For specified analytes, reliable analyte quantification directly derived from the ratio of peak areas of labelled and unlabelled analyte without the need for a time consuming multi-point calibration series is possible. This DIDA approach is of considerable practical importance for the application of LC-MS/MS in the clinical laboratory where short turnaround times often have high priority.

  16. Odorant Screening and Quantitation of Thiols in Carmenere Red Wine by Gas Chromatography-Olfactometry and Stable Isotope Dilution Assays.

    PubMed

    Pavez, Carolina; Agosin, Eduardo; Steinhaus, Martin

    2016-05-04

    The sensory impact of thiols in Vitis vinifera 'Carmenere' red wines was evaluated. For this purpose, aroma extract dilution analysis was applied to the thiols isolated from a Carmenere red wine by affinity chromatography with a mercurated agarose gel. Results revealed the presence of four odorants, identified as 2-furanylmethanethiol, 3-sulfanylhexyl acetate, 3-sulfanyl-1-hexanol, and 2-methyl-3-sulfanyl-1-butanol, with the latter being described here for the first time in Carmenere red wines. Quantitation of the four thiols in the Carmenere wine screened by aroma extract dilution analysis and in three additional Carmenere wines by stable isotope dilution assays resulted in concentrations above the respective orthonasal odor detection threshold values. Triangle tests applied to wine model solutions with and without the addition of the four thiols showed significant differences, thus suggesting that the compounds do have the potential to influence the overall aroma of red wine.

  17. Reductive amination derivatization for the quantification of garlic components by isotope dilution analysis.

    PubMed

    Lin, Yi-Reng; Huang, Mei-Fang; Wu, You-Ying; Liu, Meng-Chieh; Huang, Jing-Heng; Chen, Ziyu; Shiue, Yow-Ling; Wu, Chia-En; Liang, Shih-Shin

    2017-09-01

    In this work, we synthesized internal standards for four garlic organosulfur compounds (OSCs) by reductive amination with 13 C, D 2 -formaldehyde, and developed an isotope dilution analysis method to quantitate these organosulfur components in garlic samples. Internal standards were synthesized for internal absolute quantification of S-allylcysteine (SAC), S-allylcysteine sulfoxide (alliin), S-methylcysteine (SMC), and S-ethylcysteine (SEC). We used a multiple reaction monitoring (MRM) to detect 13 C, D 2 -formaldehyde-modified OSCs by ultrahigh-performance liquid phase chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) and obtained MS spectra showing different ratios of 13 C, D 2 -formaldehyde-modified and H 2 -formaldehyde-modified compounds. The resulting labeled and unlabeled OSCs were exhibited correlation coefficient (R 2 ) ranged from 0.9989 to 0.9994, respectively. The average recoveries for four OSCs at three concentration levels ranged from 89% to 105%. By 13 C, D 2 -formaldehyde and sodium cyanoborohydride, the reductive amination-based method can be utilized to generate novel internal standard for isotope dilution and to extend the quantitative application. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Total synthesis of isotopically enriched Si-29 silica NPs as potential spikes for isotope dilution quantification of natural silica NPs.

    PubMed

    Pálmai, Marcell; Szalay, Roland; Bartczak, Dorota; Varga, Zoltán; Nagy, Lívia Naszályi; Gollwitzer, Christian; Krumrey, Michael; Goenaga-Infante, Heidi

    2015-05-01

    A new method was developed for the preparation of highly monodisperse isotopically enriched Si-29 silica nanoparticles ((29)Si-silica NPs) with the purpose of using them as spikes for isotope dilution mass spectrometry (IDMS) quantification of silica NPs with natural isotopic distribution. Si-29 tetraethyl orthosilicate ((29)Si-TEOS), the silica precursor was prepared in two steps starting from elementary silicon-29 pellets. In the first step Si-29 silicon tetrachloride ((29)SiCl4) was prepared by heating elementary silicon-29 in chlorine gas stream. By using a multistep cooling system and the dilution of the volatile and moisture-sensitive (29)SiCl4 in carbon tetrachloride as inert medium we managed to reduce product loss caused by evaporation. (29)Si-TEOS was obtained by treating (29)SiCl4 with absolute ethanol. Structural characterisation of (29)Si-TEOS was performed by using (1)H and (13)C nuclear magnetic resonance (NMR) spectroscopy and Fourier-transform infrared (FTIR) spectroscopy. For the NP preparation, a basic amino acid catalysis route was used and the resulting NPs were analysed using transmission electron microscopy (TEM), small angle X-ray scattering (SAXS), dynamic light scattering (DLS) and zeta potential measurements. Finally, the feasibility of using enriched NPs for on-line field-flow fractionation coupled with multi-angle light scattering and inductively coupled plasma mass spectrometry (FFF/MALS/ICP-MS) has been demonstrated. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. STUDIES ON ANALYTICAL METHODS FOR TRACE ELEMENTS IN METALS BY USING RADIOACTIVE ISOTOPE. III. DETERMINATION OF TANTALUM BY MEANS OF ISOTOPE DILUTION METHOD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amano, H.

    1959-10-01

    The determination of tantalum by the isotope dilution method in the presence of niobium was investigated by the use of the radioisotope Ta/sup 185/. Tantalum was separated from niobium as tantalum-tannin precipitate under the optimum conditions of a pH of 1.9 to 2.5 and a tantalum/niobium ratio of up to 1/ 50. If niobium was present in amounts 100 times or more that of tantalum, reprecipitation was needed. The reciprocal of the specific activity of tanthlum pentoxide precipitate was in a linear relation to the change in the amount of tantalum added. The recommended method gave an accurate result inmore » the determination of tantalum in steal. (auth)« less

  20. An Isotopic Dilution Experiment Using Liquid Scintillation: A Simple Two-System, Two-Phase Analysis.

    ERIC Educational Resources Information Center

    Moehs, Peter J.; Levine, Samuel

    1982-01-01

    A simple isotonic, dilution analysis whose principles apply to methods of more complex radioanalyses is described. Suitable for clinical and instrumental analysis chemistry students, experimental manipulations are kept to a minimum involving only aqueous extraction before counting. Background information, procedures, and results are discussed.…

  1. Determination of human-use pharmaceuticals in filtered water by direct aqueous injection: high-performance liquid chromatography/tandem mass spectrometry

    USGS Publications Warehouse

    Furlong, Edward T.; Noriega, Mary C.; Kanagy, Christopher J.; Kanagy, Leslie K.; Coffey, Laura J.; Burkhardt, Mark R.

    2014-01-01

    This report describes a method for the determination of 110 human-use pharmaceuticals using a 100-microliter aliquot of a filtered water sample directly injected into a high-performance liquid chromatograph coupled to a triple-quadrupole tandem mass spectrometer using an electrospray ionization source operated in the positive ion mode. The pharmaceuticals were separated by using a reversed-phase gradient of formic acid/ammonium formate-modified water and methanol. Multiple reaction monitoring of two fragmentations of the protonated molecular ion of each pharmaceutical to two unique product ions was used to identify each pharmaceutical qualitatively. The primary multiple reaction monitoring precursor-product ion transition was quantified for each pharmaceutical relative to the primary multiple reaction monitoring precursor-product transition of one of 19 isotope-dilution standard pharmaceuticals or the pesticide atrazine, using an exact stable isotope analogue where possible. Each isotope-dilution standard was selected, when possible, for its chemical similarity to the unlabeled pharmaceutical of interest, and added to the sample after filtration but prior to analysis. Method performance for each pharmaceutical was determined for reagent water, groundwater, treated drinking water, surface water, treated wastewater effluent, and wastewater influent sample matrixes that this method will likely be applied to. Each matrix was evaluated in order of increasing complexity to demonstrate (1) the sensitivity of the method in different water matrixes and (2) the effect of sample matrix, particularly matrix enhancement or suppression of the precursor ion signal, on the quantitative determination of pharmaceutical concentrations. Recovery of water samples spiked (fortified) with the suite of pharmaceuticals determined by this method typically was greater than 90 percent in reagent water, groundwater, drinking water, and surface water. Correction for ambient environmental concentrations of pharmaceuticals hampered the determination of absolute recoveries and method sensitivity of some compounds in some water types, particularly for wastewater effluent and influent samples. The method detection limit of each pharmaceutical was determined from analysis of pharmaceuticals fortified at multiple concentrations in reagent water. The calibration range for each compound typically spanned three orders of magnitude of concentration. Absolute sensitivity for some compounds, using isotope-dilution quantitation, ranged from 0.45 to 94.1 nanograms per liter, primarily as a result of the inherent ionization efficiency of each pharmaceutical in the electrospray ionization process. Holding-time studies indicate that acceptable recoveries of pharmaceuticals can be obtained from filtered water samples held at 4 °C for as long as 9 days after sample collection. Freezing samples to provide for storage for longer periods currently (2014) is under evaluation by the National Water Quality Laboratory.

  2. Calcium tracer kinetics show decreased irreversible flow to bone in glucocorticoid treated patients.

    PubMed

    Goans, R E; Weiss, G H; Abrams, S A; Perez, M D; Yergey, A L

    1995-06-01

    Osteopenia resulting from pharmacologic doses of glucocorticoids is well known. Previously, there has been no satisfactory quantitative model describing the kinetics of calcium flow in subjects on chronic steroid use. A mathematical model of calcium isotope interaction with bone is described and applied to determine an estimate of kinetic parameters characterizing these changes. Calcium tracer dilution kinetics after a bolus injection of 42Ca were measured in 14 subjects with juvenile dermatomyositis, 6 on prednisone regimens and 8 on treatment regimens without prednisone. Irreversible tracer loss from plasma bone is found to be significantly reduced (P = 0.043) in the glucocorticoid-treated patients compared with patients on nonsteroid regimens. Reversible flow to bone is noted to be similar in the two groups. These results suggest a direct effect of glucocorticoids on osteoblast function.

  3. Isotopic determinations of rhenium and osmium in meteorites by using fusion, distillation and ion-exchange separations

    USGS Publications Warehouse

    Morgan, J.W.; Walker, R.J.

    1989-01-01

    A stable isotope-dilution method using resonance ionization mass spectrometry is suitable for the determination of rhenium and osmium abundances and osmium isotopic composition in carbonaceous chondrites and iron meteorites. The chemical procedure involves sodium peroxide fusion, followed by distillation of osmium from sulfuric acid/hydrogen peroxide and subsequent anion-exchange separation of rhenium from the same solution. ?? 1989.

  4. Is the gas-particle partitioning in alpha-pinene secondary organic aerosol reversible?

    NASA Astrophysics Data System (ADS)

    Grieshop, Andrew P.; Donahue, Neil M.; Robinson, Allen L.

    2007-07-01

    This paper discusses the reversibility of gas-particle partitioning in secondary organic aerosol (SOA) formed from α-pinene ozonolysis in a smog chamber. Previously, phase partitioning has been studied quantitatively via SOA production experiments and qualitatively by perturbing temperature and observing particle evaporation. In this work, two methods were used to isothermally dilute the SOA: an external dilution sampler and an in-chamber technique. Dilution caused some evaporation of SOA, but repartitioning took place on a time scale of tens of minutes to hours-consistent with an uptake coefficient on the order of 0.001-0.01. However, given sufficient time, α-pinene SOA repartitions reversibly based on comparisons with data from conventional SOA yield experiments. Further, aerosol mass spectrometer (AMS) data indicate that the composition of SOA varies with partitioning. These results suggest that oligomerization observed in high-concentration laboratory experiments may be a reversible process and underscore the complexity of the kinetics of formation and evaporation of SOA.

  5. Simultaneous Measurement of Tabun, Sarin, Soman, Cyclosarin, VR, VX, and VM Adducts to Tyrosine in Blood Products by Isotope Dilution UHPLC-MS/MS

    PubMed Central

    Crow, Brian S.; Pantazides, Brooke G.; Quiñones-González, Jennifer; Garton, Joshua W.; Carter, Melissa D.; Perez, Jonas W.; Watson, Caroline M.; Tomcik, Dennis J.; Crenshaw, Michael D.; Brewer, Bobby N.; Riches, James R.; Stubbs, Sarah J.; Read, Robert W.; Evans, Ronald A.; Thomas, Jerry D.; Blake, Thomas A.; Johnson, Rudolph C.

    2015-01-01

    This work describes a new specific, sensitive, and rapid stable isotope dilution method for the simultaneous detection of the organophosphorus nerve agents (OPNAs) tabun (GA), sarin (GB), soman (GD), cyclosarin (GF), VR, VX, and VM adducts to tyrosine (Tyr). Serum, plasma, and lysed whole blood samples (50 µL) were prepared by protein precipitation followed by digestion with Pronase. Specific Tyr adducts were isolated from the digest by a single solid phase extraction (SPE) step, and the analytes were separated by reversed-phase ultra high performance liquid chromatography (UHPLC) gradient elution in less than 2 min. Detection was performed on a triple quadrupole tandem mass spectrometer using time-triggered selected reaction monitoring (SRM) in positive electrospray ionization (ESI) mode. The calibration range was characterized from 0.100–50.0 ng/mL for GB– and VR– Tyr and 0.250–50.0 ng/mL for GA–, GD–, GF–, and VX/VM–Tyr (R2 ≥ 0.995). Inter- and intra-assay precision had coefficients of variation of ≤17 and ≤10%, respectively, and the measured concentration accuracies of spiked samples were within 15% of the targeted value for multiple spiking levels. The limit of detection was calculated to be 0.097, 0.027, 0.018, 0.074, 0.023, and 0.083 ng/mL for GA–, GB–, GD–, GF–, VR–, and VX/VM–Tyr, respectively. A convenience set of 96 serum samples with no known nerve agent exposure was screened and revealed no baseline values or potential interferences. This method provides a simple and highly specific diagnostic tool that may extend the time postevent that a confirmation of nerve agent exposure can be made with confidence. PMID:25286390

  6. Simultaneous measurement of tabun, sarin, soman, cyclosarin, VR, VX, and VM adducts to tyrosine in blood products by isotope dilution UHPLC-MS/MS.

    PubMed

    Crow, Brian S; Pantazides, Brooke G; Quiñones-González, Jennifer; Garton, Joshua W; Carter, Melissa D; Perez, Jonas W; Watson, Caroline M; Tomcik, Dennis J; Crenshaw, Michael D; Brewer, Bobby N; Riches, James R; Stubbs, Sarah J; Read, Robert W; Evans, Ronald A; Thomas, Jerry D; Blake, Thomas A; Johnson, Rudolph C

    2014-10-21

    This work describes a new specific, sensitive, and rapid stable isotope dilution method for the simultaneous detection of the organophosphorus nerve agents (OPNAs) tabun (GA), sarin (GB), soman (GD), cyclosarin (GF), VR, VX, and VM adducts to tyrosine (Tyr). Serum, plasma, and lysed whole blood samples (50 μL) were prepared by protein precipitation followed by digestion with Pronase. Specific Tyr adducts were isolated from the digest by a single solid phase extraction (SPE) step, and the analytes were separated by reversed-phase ultra high performance liquid chromatography (UHPLC) gradient elution in less than 2 min. Detection was performed on a triple quadrupole tandem mass spectrometer using time-triggered selected reaction monitoring (SRM) in positive electrospray ionization (ESI) mode. The calibration range was characterized from 0.100-50.0 ng/mL for GB- and VR-Tyr and 0.250-50.0 ng/mL for GA-, GD-, GF-, and VX/VM-Tyr (R(2) ≥ 0.995). Inter- and intra-assay precision had coefficients of variation of ≤17 and ≤10%, respectively, and the measured concentration accuracies of spiked samples were within 15% of the targeted value for multiple spiking levels. The limit of detection was calculated to be 0.097, 0.027, 0.018, 0.074, 0.023, and 0.083 ng/mL for GA-, GB-, GD-, GF-, VR-, and VX/VM-Tyr, respectively. A convenience set of 96 serum samples with no known nerve agent exposure was screened and revealed no baseline values or potential interferences. This method provides a simple and highly specific diagnostic tool that may extend the time postevent that a confirmation of nerve agent exposure can be made with confidence.

  7. Simultaneous determination of iron, cadmium, zinc, copper, nickel, lead, and uranium in seawater by stable isotope dilution spark source mass spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mykytiuk, A.P.; Russell, D.S.; Sturgeon, R.E.

    Trace concentrations (ng/mL) of Fe, Cd, Zn, Cu, Ni, Pb, U, and Co have been determined in seawater by stable isotope dilution spark source mass spectrometry. The seawater samples were preconcentrated on the ion exchanger Chelex-100 and the concentrate was evaporated on a graphite or silver electrode. The results are compared with those obtained by graphite furnace atomic absorption spectrometry and inductively coupled plasma emission spectrometry. The technique avoids the use of calibration standards and is capable of producing results in cases where the analyte is only partially recovered. 2 tables.

  8. Gravitational effects on plant growth hormone concentration

    NASA Astrophysics Data System (ADS)

    Bandurski, Robert S.; Schulze, Aga

    Numerous studies, particularly those of H. Dolk in the 1930's, established by means of bio-assay, that more growth hormone diffused from the lower, than from the upper side of a gravity-stimulated plant shoot. Now, using an isotope dilution assay, with 4,5,6,7 tetradeutero indole-3-acetic acid as internal standard, and selected ion monitoring-gas chromatography-mass spectrometry as the method of determination, we have confirmed Dolk's finding and established that the asymmetrically distributed hormone is, in fact, indole-3-acetic acid (IAA). This is the first physico-chemical demonstration that there is more free IAA on the lower sides of a geo-stimulated plant shoot. We have also shown that free IAA occurs primarily in the conductive vascular tissues of the shoot, whereas IAA esters predominate in the growing cortical cells. Now, using an especially sensitive gas chromatographic isotope dilution assay we have found that the hormone asymmetry also occurs in the non-vascular tissue. Currently, efforts are directed to developing isotope dilution assays, with picogram sensitivity, to determine how this asymmetry of IAA distribution is attained so as to better understand how the plant perceives the geo-stimulus.

  9. Fate and lability of silver in soils: Effect of ageing

    EPA Science Inventory

    The fate and lability of added soluble Ag in soils over time was examined by measurement of labile metal (E-value) by isotopic dilution using the 110mAg radioactive isotope and the solid-phase speciation of Ag by X-ray absorption near edge structure (XANES) spectrosco...

  10. Uranium disequilibrium in groundwater: An isotope dilution approach in hydrologic investigations

    USGS Publications Warehouse

    Osmond, J.K.; Rydell, H.S.; Kaufman, M.I.

    1968-01-01

    The distribution and environmental disequilibrium patterns of naturally occurring uranium isotopes (U234 and U238) in waters of the Floridan aquifer suggest that variations in the ratios of isotopic activity and concentrations can be used quantitatively to evaluate mixing proportions of waters from differing sources. Uranium is probably unique in its potential for this approach, which seems to have general usefulness in hydrologic investigations.

  11. Isotopic separation of acetaldehyde and methanol from their deuterated isotopologues on a porous layer open tubular column allows quantification by stable isotope dilution without mass spectrometric detection.

    PubMed

    Schmarr, Hans-Georg; Wacker, Michael; Mathes, Maximilian

    2017-01-20

    An isotopic separation of acetaldehyde and acetaldehyde-2,2,2-d3 was achieved in a temperature programmed run on a porous layer open tubular (PLOT) capillary column coated with particles of divinylbenzene ethylene glycol/dimethylacrylate (Rt ® -U-BOND). This is the prerequisite for the development of quantitative analytical methods based on a stable isotope dilution assay (SIDA) without a mass spectrometric detection (non-MS SIDA). For routine analysis a flame ionization detector (FID) can thus be applied as a robust and low-cost alternative. In a preliminary study, static headspace extraction and gas chromatographic separation (HS-GC-FID) of acetaldehyde in aqueous solutions was shown as an application. Good linearity was obtained in a calibration range from 0.4 to 40mgL -1 , with peak integration benefitting from the inverse isotope effect encountered on the specific porous polymer. Furthermore, separation of methanol and deuterated methanol (d3) could also be achieved under the same chromatographic conditions. The achieved isotopic separation of these important volatile compounds now allows non-MS SIDA-based methods that are still to be developed. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Development of a direct procedure for the measurement of sulfur isotope variability in beers by MC-ICP-MS.

    PubMed

    Giner Martínez-Sierra, J; Santamaria-Fernandez, R; Hearn, R; Marchante Gayón, J M; García Alonso, J I

    2010-04-14

    In this work, a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS) was evaluated for the direct measurement of sulfur stable isotope ratios in beers as a first step toward a general study of the natural isotope variability of sulfur in foods and beverages. Sample preparation consisted of a simple dilution of the beers with 1% (v/v) HNO(3). It was observed that different sulfur isotope ratios were obtained for different dilutions of the same sample indicating that matrix effects affected differently the transmission of the sulfur ions at masses 32, 33, and 34 in the mass spectrometer. Correction for mass bias related matrix effects was evaluated using silicon internal standardization. For that purpose, silicon isotopes at masses 29 and 30 were included in the sulfur cup configuration and the natural silicon content in beers used for internal mass bias correction. It was observed that matrix effects on differential ion transmission could be corrected adequately using silicon internal standardization. The natural isotope variability of sulfur has been evaluated by measuring 26 different beer brands. Measured delta(34)S values ranged from -0.2 to 13.8 per thousand. Typical combined standard uncertainties of the measured delta(34)S values were < or = 2 per thousand. The method has therefore great potential to study sulfur isotope variability in foods and beverages.

  13. Headspace solid-phase microextraction and gas chromatographic analysis of low-molecular-weight sulfur volatiles with pulsed flame photometric detection and quantification by a stable isotope dilution assay.

    PubMed

    Ullrich, Sebastian; Neef, Sylvia K; Schmarr, Hans-Georg

    2018-02-01

    Low-molecular-weight volatile sulfur compounds such as thiols, sulfides, disulfides as well as thioacetates cause a sulfidic off-flavor in wines even at low concentration levels. The proposed analytical method for quantification of these compounds in wine is based on headspace solid-phase microextraction, followed by gas chromatographic analysis with sulfur-specific detection using a pulsed flame photometric detector. Robust quantification was achieved via a stable isotope dilution assay using commercial and synthesized deuterated isotopic standards. The necessary chromatographic separation of analytes and isotopic standards benefits from the inverse isotope effect realized on an apolar polydimethylsiloxane stationary phase of increased film thickness. Interferences with sulfur-specific detection in wine caused by sulfur dioxide were minimized by addition of propanal. The method provides adequate validation data, with good repeatability and limits of detection and quantification. It suits the requirements of wine quality management, allowing the control of oenological treatments to counteract an eventual formation of excessively high concentration of such malodorous compounds. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Quantification of isotope-labelled and unlabelled folates in plasma, ileostomy and food samples.

    PubMed

    Büttner, Barbara E; Öhrvik, Veronica E; Witthöft, Cornelia M; Rychlik, Michael

    2011-01-01

    New stable isotope dilution assays were developed for the simultaneous quantitation of [(13)C(5)]-labelled and unlabelled 5-methyltetrahydrofolic acid, 5-formyltetrahydrofolic acid, folic acid along with unlabelled tetrahydrofolic acid and 10-formylfolic acid in clinical samples deriving from human bioavailability studies, i.e. plasma, ileostomy samples, and food. The methods were based on clean-up by strong anion exchange followed by LC-MS/MS detection. Deuterated analogues of the folates were applied as the internal standards in the stable isotope dilution assays. Assay sensitivity was sufficient to detect all relevant folates in the respective samples as their limits of detection were below 0.62 nmol/L in plasma and below 0.73 μg/100 g in food or ileostomy samples. Quantification of the [(13)C(5)]-label in clinical samples offers the possibility to differentiate between folate from endogenous body pools and the administered dose when executing bioavailability trials.

  15. Strong coupling effects in the polarized IR spectra of the chain hydrogen bond systems in imidazole crystals: H/D isotopic ?self-organization? effects in the IR spectra of isotopically diluted imidazole single crystals

    NASA Astrophysics Data System (ADS)

    Flakus, Henryk T.; Michta, Anna

    2004-11-01

    This paper presents the investigation results of the polarized IR spectra of H1245 imidazole crystals and of D1H245, D1245 and H1D245 imidazole deuterium derivative crystals. The spectra were measured using polarized light at the room temperature and at 77 K by a transmission method, for two different crystalline faces. Theoretical analysis of the results concerned linear dichroic effects, H/D isotopic and temperature effects, observed in the spectra of the hydrogen and of the deuterium bonds in imidazole crystals, at the frequency ranges of νN-H and νN-D bands. The basic crystal spectral properties can be satisfactorily interpreted in a quantitative way for a hydrogen bond linear dimer model. Such a model explains not only a two-branch structure of the νN-H and νN-D bands in crystalline spectra, but also some essential linear dichroic effects in the band frequency ranges, for isotopically diluted crystals. Model calculations, performed within the limits of the strong-coupling model, allowed for quantitative interpretation and for understanding of the basic properties of the hydrogen bond IR spectra of imidazole crystals, H/D isotopic, temperature and dichroic effects included. The results allowed verification of theoretical models proposed recently for the imidazole crystal spectra generation mechanisms. In the scope of our studies, the mechanism of H/D isotopic self-organization processes, taking place in the crystal hydrogen bond lattices, was also recognized. It was proved that for isotopically diluted crystalline samples of imidazole, a non-random distribution of protons and deuterons exclusively occurs in some restricted fragments (domains) of open chains of the hydrogen-bonded molecules. Nevertheless, these co-operative interactions between the hydrogen bonds do not concern adjacent fragments of neighboring hydrogen bond chains in the lattice. Analysis of the isotopic self-organization effects in the spectra of imidazole crystals delivered crucial arguments for understanding of the nature of the hydrogen bond spectra generation mechanisms.

  16. Isotope dilution inductively coupled plasma quadrupole mass spectrometry in connection with a chromatographic separation for ultra trace determinations of platinum group elements (Pt, Pd, Ru, Ir) in environmental samples.

    PubMed

    Müller, M; Heumann, K G

    2000-09-01

    An isotope dilution inductively coupled plasma quadrupole mass spectrometric (ID-ICP-QMS) method was developed for the simultaneous determination of the platinum group elements Pt, Pd, Ru, and Ir in environmental samples. Spike solutions, enriched with the isotopes 194Pt, 108Pd, 99Ru, and 191Ir, were used for the isotope dilution step. Interfering elements were eliminated by chromatographic separation using an anion-exchange resin. Samples were dissolved with aqua regia in a high pressure asher. Additional dissolution of possible silicate portions by hydrofluoric acid was usually not necessary. Detection limits of 0.15 ng x g(-1), 0.075 ng x g(-1), and 0.015 ng x g(-1) were achieved for Pt, Pd, Ru, and Ir, respectively, using sample weights of only 0.2 g. The reliability of the ID-ICP-QMS method was demonstrated by analyzing a Canadian geological reference material and by participating in an interlaboratory study for the determination of platinum and palladium in a homogenized road dust sample. Surface soil, sampled at different distances from a highway, showed concentrations in the range of 0.1-87 ng x g(-1). An exponential decrease of the platinum and palladium concentration with increasing distance and a small anthropogenic contribution to the natural background concentration of ruthenium and iridium was found in these samples.

  17. Stable isotope tracer dilution for quantifying very low-density lipoprotein-triacylglycerol kinetics in man.

    PubMed

    Sidossis, Labros S; Magkos, Faidon; Mittendorfer, Bettina; Wolfe, Robert R

    2004-08-01

    A number of approaches have been employed in the past to measure very low-density lipoprotein (VLDL) triacylglycerol (TG) kinetics in humans in vivo, varying in the selection of tracer and mode of administration. All, however, make use of labeled TG precursors and more or less complicated mathematical models to derive the kinetic parameters of interest. The aim of the present study was to develop a conceptually straightforward method, based on the traditional tracer infusion technique, for quantifying VLDL-TG production rates in man using stable isotopes. Our approach involves ingestion of [U-13C3]glycerol to endogenously label the glycerol in VLDL-TG, plasmapheresis, isolation of the newly 13C-labeled VLDL from plasma, and administration within the next 2-3 days via a primed constant autologous reinfusion. This procedure produces enough tracer for a priming dose plus 2-3 h of infusion. In the physiological conditions examined (basal and hyperglycemic states, fat- and carbohydrate-rich diets), with almost 3-fold ranging VLDL-TG pool sizes, a steady state in plasma VLDL-TG glycerol tracer-to-tracee ratio was readily achieved within 2 h. Consequently, calculations are made according to the isotope dilution principle, thus avoiding assumptions implicit in more complicated models. The stable isotope VLDL-TG tracer dilution method offers an alternative and reliable tool for the determination of endogenous VLDL-TG kinetics in man under a variety of metabolic states. Copyright 2003 Elsevier Ltd.

  18. Modification of a commercial gas chromatography isotope ratio mass spectrometer for on-line carbon isotope dilution: Evaluation of its analytical characteristics for the quantification of organic compounds.

    PubMed

    Alonso Sobrado, Laura; Robledo Fernández, Mario; Cueto Díaz, Sergio; Ruiz Encinar, Jorge; García Alonso, J Ignacio

    2015-11-06

    We describe the instrumental modification of a commercial gas chromatography isotope ratio mass spectrometer (GC-IRMS) and its application for on-line carbon isotope dilution. The main modification consisted in the addition of a constant flow of enriched (13)CO2 diluted in helium after the chromatographic column through the splitter holder located inside the chromatographic oven of the instrument. In addition, and in contrast to the conventional mode of operation of GC-IRMS instruments where the signal at m/z 45 is amplified 100-fold with respect to the signal at m/z 44, the same signal amplification was used in both Faraday cups at m/z 44 and 45. Under these conditions isotope ratio precision for the ratio 44/45 was around 0.05% RSD (n=50). The evaluation of the instrument was performed with mixtures of organic compounds including 11 n-alkanes, 16 PAHs, 12 PCBs and 3 benzothiophenes. It was observed that compounds of very different boiling points could be analysed without discrimination in the injector when a Programmable Temperature Vaporizer (PTV) injector was employed. Moreover, the presence of heteroatoms (Cl or S) in the structure of the organic compounds did not affect their combustion efficiency and therefore the trueness of the results. Quantitative results obtained for all the analytes assayed were excellent in terms of precision (<3% RSD) and accuracy (average relative error≤4%) and what is more important using a single and simple generic internal standard for quantification. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry-recommended reference measurement procedure and reference materials for glycated albumin determination.

    PubMed

    Takei, Izumi; Hoshino, Tadao; Tominaga, Makoto; Ishibashi, Midori; Kuwa, Katsuhiko; Umemoto, Masao; Tani, Wataru; Okahashi, Mikiko; Yasukawa, Keiko; Kohzuma, Takuji; Sato, Asako

    2016-01-01

    Glycated albumin is an intermediate glycaemic control marker for which there are several measurement procedures with entirely different reference intervals. We have developed a reference measurement procedure for the purpose of standardizing glycated albumin measurements. The isotope dilution liquid chromatography/tandem mass spectrometry method was developed as a reference measurement procedure for glycated albumin. The stable isotopes of lysine and fructosyl-lysine, which serve as an internal standard, were added to albumin isolated from serum, followed by hydrogenation. After hydrolysis of albumin with hot hydrochloric acid, the liberated lysine and fructosyl-lysine were measured by liquid chromatography/tandem mass spectrometry, and their concentrations were determined from each isotope ratio. The reference materials (JCCRM611) for determining of glycated albumin were prepared from pooled patient blood samples. The isotope dilution-tandem mass spectrometry calibration curve of fructosyl-lysine and lysine showed good linearity (r = 0.999). The inter-assay and intra-assay coefficient of variation values of glycated albumin measurement were 1.2 and 1.4%, respectively. The glycated albumin values of serum in patients with diabetes assessed through the use of this method showed a good relationship with routine measurement procedures (r = 0.997). The relationship of glycated albumin values of the reference material (JCCRM611) between these two methods was the same as the relationship with the patient serum samples. The Committee on Diabetes Mellitus Indices of the Japan Society of Clinical Chemistry recommends the isotope dilution liquid chromatography/tandem mass spectrometry method as a reference measurement procedure, and JCCRM611 as a certified reference material for glycated albumin measurement. In addition, we recommend the traceability system for glycated albumin measurement. © The Author(s) 2015.

  20. Analysis of hydrazine in drinking water by isotope dilution gas chromatography/tandem mass spectrometry with derivatization and liquid-liquid extraction.

    PubMed

    Davis, William E; Li, Yongtao

    2008-07-15

    A new isotope dilution gas chromatography/chemical ionization/tandem mass spectrometric method was developed for the analysis of carcinogenic hydrazine in drinking water. The sample preparation was performed by using the optimized derivatization and multiple liquid-liquid extraction techniques. Using the direct aqueous-phase derivatization with acetone, hydrazine and isotopically labeled hydrazine-(15)N2 used as the surrogate standard formed acetone azine and acetone azine-(15)N2, respectively. These derivatives were then extracted with dichloromethane. Prior to analysis using methanol as the chemical ionization reagent gas, the extract was dried with anhydrous sodium sulfate, concentrated through evaporation, and then fortified with isotopically labeled N-nitrosodimethylamine-d6 used as the internal standard to quantify the extracted acetone azine-(15)N2. The extracted acetone azine was quantified against the extracted acetone azine-(15)N2. The isotope dilution standard calibration curve resulted in a linear regression correlation coefficient (R) of 0.999. The obtained method detection limit was 0.70 ng/L for hydrazine in reagent water samples, fortified at a concentration of 1.0 ng/L. For reagent water samples fortified at a concentration of 20.0 ng/L, the mean recoveries were 102% with a relative standard deviation of 13.7% for hydrazine and 106% with a relative standard deviation of 12.5% for hydrazine-(15)N2. Hydrazine at 0.5-2.6 ng/L was detected in 7 out of 13 chloraminated drinking water samples but was not detected in the rest of the chloraminated drinking water samples and the studied chlorinated drinking water sample.

  1. Quantification of N-acetyl- and N-glycolylneuraminic acids by a stable isotope dilution assay using high-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Allevi, Pietro; Femia, Eti Alessandra; Costa, Maria Letizia; Cazzola, Roberta; Anastasia, Mario

    2008-11-28

    The present report describes a method for the quantification of N-acetyl- and N-glycolylneuraminic acids without any derivatization, using their (13)C(3)-isotopologues as internal standards and a C(18) reversed-phase column modified by decylboronic acid which allows for the first time a complete chromatographic separation between the two analytes. The method is based on high-performance liquid chromatographic coupled with electrospray ion-trap mass spectrometry. The limit of quantification of the method is 0.1mg/L (2.0ng on column) for both analytes. The calibration curves are linear for both sialic acids over the range of 0.1-80mg/L (2.0-1600ng on column) with a correlation coefficient greater than 0.997. The proposed method was applied to the quantitative determination of sialic acids released from fetuin as a model of glycoproteins.

  2. Easy and Fast Method for the Determination of Biogenic Amines in Fish and Fish Products with Liquid Chromatography Coupled to Orbitrap Tandem Mass Spectrometry.

    PubMed

    Kaufmann, Anton; Maden, Kathryn

    2018-03-01

    A quantitative method for the determination of biogenic amines was developed. The method is characterized by the virtual absence of sample cleanup and does not require a derivatization reaction. Diluted extracts are centrifuged, filtrated, and directly injected into an ultra-HPLC column, which is coupled to a single-stage high-resolution mass spectrometer (Orbitrap). The chromatography is based on a reversed-phase column and an eluent containing an ion-pairing agent (heptafluorobutyric acid). The high sensitivity of the instrument permits the injection of very diluted extracts, which ensures stable retention times and the virtual absence of signal suppression effects. In addition, the quantification of histamine (a regulated compound) is further aided by the use of an isotopically labeled internal standard. The method was validated for three fish-based matrixes. Both the sample processing and the analytical measurement are very fast; hence, the methodology is ideal for high-throughput work. In addition, the method is significantly more selective than conventional methods (i.e., derivatization followed by LC with UV/fluorescence (FL) detection) for biogenic amines. A comparison showed that LC-UV/FL methods can produce false-positive findings due to coeluting matrix compounds.

  3. Online extraction LC-MS/MS method for the simultaneous quantitative confirmation of urine drugs of abuse and metabolites: amphetamines, opiates, cocaine, cannabis, benzodiazepines and methadone.

    PubMed

    de Jager, Andrew D; Bailey, Neville L

    2011-09-01

    A rapid LC-MS/MS method for confirmatory testing of five major categories of drugs of abuse (amphetamine-type substances, opiates, cocaine, cannabis metabolites and benzodiazepines) in urine has been developed. All drugs of abuse mandated by the Australian/New Zealand Standard AS/NZS 4308:2008 are quantified in a single chromatographic run. Urine samples are diluted with a mixture of isotope labelled internal standards. An on-line trap-and-flush approach, followed by LC-ESI-MS/MS has been successfully used to process samples in a functioning drugs of abuse laboratory. Following injection of diluted urine samples, compounds retained on the trap cartridge are flushed onto a reverse-phase C18 HPLC column (5-μm particle size) with embedded hydrophylic functionality. A total chromatographic run-time of 15 min is required for adequate resolution. Automated quantitation software algorithms have been developed in-house using XML scripting to partially automate the identification of positive samples, taking into account ion ratio (IR) and retention times (Rt). The sensitivity of the assay was found to be adequate for the quantitation of drugs in urine at and below the confirmation cut-off concentrations prescribed by AS/NZS 4308:2008. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Determination of lead, uranium, thorium, and thallium in silicate glass standard materials by isotope dilution mass spectrometry

    USGS Publications Warehouse

    Barnes, I.L.; Garner, E.L.; Gramlich, J.W.; Moore, L.J.; Murphy, T.J.; Machlan, L.A.; Shields, W.R.; Tatsumoto, M.; Knight, R.J.

    1973-01-01

    A set of four standard glasses has been prepared which have been doped with 61 different elements at the 500-, 50-, 1-, and 0.02-ppm level. The concentrations of lead, uranium, thorium, and thallium have been determined by isotope dilution mass spectrometry at a number of points in each of the glasses. The results obtained from independent determinations in two laboratories demonstrate the homogeneity of the samples and that precision of the order of 0.5% (95% L.E.) may be obtained by the method even at the 20-ppb level for these elements. The chemical and mass spectrometric procedures necessary are presented.

  5. Filling the gap in Ca input-output budgets in base-poor forest ecosystems: The contribution of non-crystalline phases evidenced by stable isotopic dilution

    NASA Astrophysics Data System (ADS)

    van der Heijden, Gregory; Legout, Arnaud; Mareschal, Louis; Ranger, Jacques; Dambrine, Etienne

    2017-07-01

    In terrestrial ecosystems, plant-available pools of magnesium and calcium are assumed to be stored in the soil as exchangeable cations adsorbed on the surface of mineral and/or organic particles. The pools of exchangeable magnesium and calcium are measured by ion-exchange soil extractions. These pools are sustained in the long term by the weathering of primary minerals in the soil and atmospheric inputs. This conceptual model is the base of input-output budgets from which soil acidification and the sustainability of soil chemical fertility is inferred. However, this model has been questioned by data from long-term forest ecosystem monitoring sites, particularly for calcium. Quantifying the contribution of atmospheric inputs, ion exchange and weathering of both primary, secondary and non-crystalline phases to tree nutrition in the short term is challenging. In this study, we developed and applied a novel isotopic dilution technique using the stable isotopes of magnesium and calcium to study the contribution of the different soil phases to soil solution chemistry in a very acidic soil. The labile pools of Mg and Ca in the soil (pools in equilibrium with the soil solution) were isotopically labeled by spraying a solution enriched in 26Mg and 44Ca on the soil. Labeled soil columns were then percolated with a dilute acid solution during a 3-month period and the isotopic dilution of the tracers was monitored in the leaching solution, in the exchangeable (2 sequential 1 mol L-1 ammonium acetate extractions) and non-crystalline (2 sequential soil digestions: oxalic acid followed by nitric acid) phases. Significant amounts of Mg and Ca isotope tracer were recovered in the non-crystalline soil phases. These phases represented from 5% to 25% and from 24% to 50%, respectively, of the Mg and Ca labile pools during the experiment. Our results show that non-crystalline phases act as both a source and a sink of calcium and magnesium in the soil, and contribute directly to soil solution chemistry on very short-term time scales. These phases are very abundant in acid soils and, in the present study, represent a substantial calcium pool (equivalent in size to the Ca exchangeable pool). The gradual isotopic dilution of Mg and Ca isotope ratios in the leaching solution during the experiment evidenced an input flux of Mg and Ca originating from a pool other than the labile pool. While the Mg input flux originated primarily from the weathering of primary minerals and secondarily from the non-crystalline phases, the Ca input flux originated primarily from the non-crystalline phases. Our results also show that the net calcium release flux from these phases may represent a significant source of calcium in forest ecosystems and actively contribute to compensating the depletion of Ca exchangeable pools in the soil. Non-crystalline phases therefore should be taken into account when computing input-output nutrient budgets and soil acid neutralizing capacity.

  6. MG Isotopic Measurement of FIB-Isolated Presolar Silicate Grains

    NASA Technical Reports Server (NTRS)

    Messenger, Scott R.; Nguyen, A.; Ito, M.; Rahman, Z.

    2010-01-01

    The majority of presolar oxide and silicate grains are ascribed to origins in low-mass red giant and asymptotic giant branch (AGB) stars based on their O isotopic ratios. However, a minor population of these grains (< 10%) has O isotopic ratios incompatible with these sources. Two principle alternative sources are higher-than-solar metallicity (Z) stars or, more likely, supernovae (SN) [1-3]. These rare (Group 4) grains [3] are characterized by enrichments in O-18, and typically also enrichments in O-17. An even rarer subset of grains with extremely large enrichments in O-17 and smaller depletions in O-18 were suggested to come from binary star systems [2]. To establish the origins of these isotopically unusual grains, it is necessary to examine isotopic systems in addition to O. Presolar silicates offer several elements diagnostic of their stellar sources and nuclear processes, including O, Si, Mg, Fe and Ca. However, the database for minor element isotopic compositions in silicates is seriously lacking. To date only two silicate grains have been analyzed for Mg [4] or Fe [5]. One major complicating factor is their small size (average 230 nm), which greatly limits the number of measurements that can be performed on any one grain and makes it more difficult to obtain statistically relevant data. This problem is compounded because the grains are identified among isotopically solar silicates, which contribute a diluting signal in isotopic measurements [1]. Thus, relatively small isotopic anomalies are missed due to this dilution effect. By applying focused ion beam (FIB) milling, we obtain undiluted Mg isotopic ratios of isolated rare presolar silicate grains to investigate their sources.

  7. Determination of the alkylpyrazine composition of coffee using stable isotope dilution-gas chromatography-mass spectrometry (SIDA-GC-MS).

    PubMed

    Pickard, Stephanie; Becker, Irina; Merz, Karl-Heinz; Richling, Elke

    2013-07-03

    A stable isotope dilution analysis based on gas chromatography-mass spectrometry analysis (SIDA-GC-MS) was developed for the quantitative analysis of 12 alkylpyrazines found in commercially available coffee samples. These compounds contribute to coffee flavor. The accuracy of this method was tested by analyzing model mixtures of alkylpyrazines. Comparisons of alkylpyrazine-concentrations suggested that water as extraction solvent was superior to dichloromethane. The distribution patterns of alkylpyrazines in different roasted coffees were quite similar. The most abundant alkylpyrazine in each coffee sample was 2-methylpyrazine, followed by 2,6-dimethylpyrazine, 2,5-dimethylpyrazine, 2-ethylpyrazine, 2-ethyl-6-methylpyrazine, 2-ethyl-5-methylpyrazine, and 2,3,5-trimethylpyrazine, respectively. Among the alkylpyrazines tested, 2,3-dimethylpyrazine, 2-ethyl-3-methylpyrazine, 2-ethyl-3,6-dimethylpyrazine, and 2-ethyl-3,5-dimethylpyrazine revealed the lowest concentrations in roasted coffee. By the use of isotope dilution analysis, the total concentrations of alkylpyrazines in commercially available ground coffee ranged between 82.1 and 211.6 mg/kg, respectively. Decaffeinated coffee samples were found to contain lower amounts of alkylpyrazines than regular coffee samples by a factor of 0.3-0.7, which might be a result of the decaffeination procedure.

  8. Solvent kinetic isotope effects of human placental alkaline phosphatase in reverse micelles.

    PubMed Central

    Huang, T M; Hung, H C; Chang, T C; Chang, G G

    1998-01-01

    Human placental alkaline phosphatase was embedded in a reverse micellar system prepared by dissolving the surfactant sodium bis(2-ethylhexyl) sulphosuccinate (Aerosol-OT) in 2,2, 4-trimethylpentane. This microemulsion system provides a convenient instrumental tool to study the possible kinetic properties of the membranous enzyme in an immobilized form. The pL (pH/p2H) dependence of hydrolysis of 4-nitrophenyl phosphate has been examined over a pL range of 8.5-12.5 in both aqueous and reverse micellar systems. Profiles of log V versus pL were Ha-bell shaped in the acidic region but reached a plateau in the basic region in which two pKa values of 9.01-9.71 and 9.86-10.48, respectively, were observed in reverse micelles. However, only one pKa value of 9.78-10.27 in aqueous solution was detected. Profiles of log V/K versus pL were bell-shaped in the acidic region. However, they were wave-shaped in the basic region in which a residue of pKa 9.10-9.44 in aqueous solution and 8.07-8.78 in reverse micelles must be dehydronated for the reaction to reach an optimum. The V/K value shifted to a lower value upon dehydronation of a pKa value of 9.80-10.62 in aqueous solution and 11.23-12.17 in reverse micelles. Solvent kinetic isotope effects were measured at three pL values. At pL 9.5, the observed isotope effect was a product of equilibrium isotope effect and a kinetic isotope effect; at pL 10.4, the log V/K value was identical in water and deuterium. The deuterium kinetic isotope effect on V/K was 1.14 in an aqueous solution and 1.16 in reverse micelles. At pL 11.0 at which the log V values reached a plateau in either solvent system, the deuterium kinetic isotope effect on V was 2.08 in an aqueous solution and 0.62 in reverse micelles. Results from a proton inventory experiment suggested that a hydron transfer step is involved in the transition state of the catalytic reaction. The isotopic fractionation factor (pi) for deuterium for the transition state (piT) increased when the pH of the solution was raised. At pL 11.0, the piT was 1.07 in reverse micelles, which corresponds to the inverse-isotope effect of the reaction in this solvent system. Normal viscosity effects on kcat and kcat/Km were observed in aqueous solution, corresponding to a diffusional controlled physical step as the rate-limiting step. We propose that the rate-limiting step of the hydrolytic reaction changes from phosphate releasing in aqueous solution to a covalent phosphorylation or dephosphorylation step in reverse micelles. PMID:9461520

  9. Solvent kinetic isotope effects of human placental alkaline phosphatase in reverse micelles.

    PubMed

    Huang, T M; Hung, H C; Chang, T C; Chang, G G

    1998-02-15

    Human placental alkaline phosphatase was embedded in a reverse micellar system prepared by dissolving the surfactant sodium bis(2-ethylhexyl) sulphosuccinate (Aerosol-OT) in 2,2, 4-trimethylpentane. This microemulsion system provides a convenient instrumental tool to study the possible kinetic properties of the membranous enzyme in an immobilized form. The pL (pH/p2H) dependence of hydrolysis of 4-nitrophenyl phosphate has been examined over a pL range of 8.5-12.5 in both aqueous and reverse micellar systems. Profiles of log V versus pL were Ha-bell shaped in the acidic region but reached a plateau in the basic region in which two pKa values of 9.01-9.71 and 9.86-10.48, respectively, were observed in reverse micelles. However, only one pKa value of 9.78-10.27 in aqueous solution was detected. Profiles of log V/K versus pL were bell-shaped in the acidic region. However, they were wave-shaped in the basic region in which a residue of pKa 9.10-9.44 in aqueous solution and 8.07-8.78 in reverse micelles must be dehydronated for the reaction to reach an optimum. The V/K value shifted to a lower value upon dehydronation of a pKa value of 9.80-10.62 in aqueous solution and 11.23-12.17 in reverse micelles. Solvent kinetic isotope effects were measured at three pL values. At pL 9.5, the observed isotope effect was a product of equilibrium isotope effect and a kinetic isotope effect; at pL 10.4, the log V/K value was identical in water and deuterium. The deuterium kinetic isotope effect on V/K was 1.14 in an aqueous solution and 1.16 in reverse micelles. At pL 11.0 at which the log V values reached a plateau in either solvent system, the deuterium kinetic isotope effect on V was 2.08 in an aqueous solution and 0.62 in reverse micelles. Results from a proton inventory experiment suggested that a hydron transfer step is involved in the transition state of the catalytic reaction. The isotopic fractionation factor (pi) for deuterium for the transition state (piT) increased when the pH of the solution was raised. At pL 11.0, the piT was 1.07 in reverse micelles, which corresponds to the inverse-isotope effect of the reaction in this solvent system. Normal viscosity effects on kcat and kcat/Km were observed in aqueous solution, corresponding to a diffusional controlled physical step as the rate-limiting step. We propose that the rate-limiting step of the hydrolytic reaction changes from phosphate releasing in aqueous solution to a covalent phosphorylation or dephosphorylation step in reverse micelles.

  10. The Osmium Isotopic Composition of Tagish Lake and Other Chondrites, Implications for Late Terrestrial Planetary Accretion

    NASA Technical Reports Server (NTRS)

    Brandon, A. D.

    2003-01-01

    The goals of this investigation are twofold. First, obtain high-precision Os isotope measurements of Tagish Lake and other chondrites by TIMS. Second, measure Re, Os, Pt, and other HSE concentrations by isotope dilution using TIMS and ICPMS. These measurements will determine whether this meteorite does in fact represent C-chondrite material with timeintegrated elevated Re/Os and Pt/Os with the implications to late accretion material characteristics.

  11. h5-HT1B receptor-mediated constitutive Gαi3-protein activation in stably transfected Chinese hamster ovary cells: an antibody capture assay reveals protean efficacy of 5-HT

    PubMed Central

    Newman-Tancredi, Adrian; Cussac, Didier; Marini, Laetitia; Touzard, Manuelle; Millan, Mark J

    2003-01-01

    Serotonin 5-HT1B receptors couple to G-proteins of the Gi/o family. However, their activation of specific G-protein subtypes is poorly characterised. Using an innovative antibody capture/guanosine-5′-0-(3-[35S]thio)-triphosphate ([35S]GTPγS) binding strategy, we characterised Gαi3 subunit activation by h5-HT1B receptors stably expressed in Chinese hamster ovary (CHO) cells. The agonists, 5-HT, alniditan and BMS181,101, stimulated Gαi3, whereas methiothepin and SB224,289 behaved as inverse agonists. The selective 5-HT1B receptor ligand, S18127, modestly stimulated Gαi3 and reversed the actions of both 5-HT and methiothepin. S18127 (1 μM) also produced parallel, dextral shifts of the 5-HT and methiothepin isotherms. Isotopic dilution experiments ([35S]GTPγS versus GTPγS) revealed high-affinity [35S]GTPγS binding to Gαi3 subunits in the absence of receptor ligands indicating constitutive activity. High-affinity [35S]GTPγS binding was increased 2.8-fold by 5-HT with an increase in the affinity of GTPγS for Gαi3 subunits. In contrast, methiothepin halved the number of high-affinity binding sites and decreased their affinity. h5-HT1B receptor-mediated Gαi3 subunit activation was dependent on the concentration of NaCl. At 300 mM, 5-HT stimulated [35S]GTPγS binding, basal Gαi3 activation was low and methiothepin was inactive. In contrast, at 10 mM NaCl, basal activity was enhanced and the inverse agonist activity of methiothepin was accentuated. Under these conditions, 5-HT decreased Gαi3 activation. In conclusion, at h5-HT1B receptors expressed in CHO cells: (i) inverse agonist induced inhibition of Gαi3, and its reversal by S18127, reveals constitutive activation of this Gα subunit; (ii) constitutive Gαi3 activation can be quantified by isotopic dilution [35S]GTPγS binding and (iii) decreasing NaCl concentrations enhances Gαi3 activation and leads to protean agonist properties of 5-HT: that is a switch to inhibition of Gαi3. PMID:12684263

  12. h5-HT(1B) receptor-mediated constitutive Galphai3-protein activation in stably transfected Chinese hamster ovary cells: an antibody capture assay reveals protean efficacy of 5-HT.

    PubMed

    Newman-Tancredi, Adrian; Cussac, Didier; Marini, Laetitia; Touzard, Manuelle; Millan, Mark J

    2003-03-01

    1. Serotonin 5-HT(1B) receptors couple to G-proteins of the Gi/o family. However, their activation of specific G-protein subtypes is poorly characterised. Using an innovative antibody capture/guanosine-5'-0-(3-[(35)S]thio)-triphosphate ([(35)S]GTPgammaS) binding strategy, we characterised Galpha(i3) subunit activation by h5-HT(1B) receptors stably expressed in Chinese hamster ovary (CHO) cells. 2. The agonists, 5-HT, alniditan and BMS181,101, stimulated Galpha(i3), whereas methiothepin and SB224,289 behaved as inverse agonists. The selective 5-HT(1B) receptor ligand, S18127, modestly stimulated Galpha(i3) and reversed the actions of both 5-HT and methiothepin. S18127 (1 micro M) also produced parallel, dextral shifts of the 5-HT and methiothepin isotherms. 3. Isotopic dilution experiments ([(35)S]GTPgammaS versus GTPgammaS) revealed high-affinity [(35)S]GTPgammaS binding to Galpha(i3) subunits in the absence of receptor ligands indicating constitutive activity. High-affinity [(35)S]GTPgammaS binding was increased 2.8-fold by 5-HT with an increase in the affinity of GTPgammaS for Galpha(i3) subunits. In contrast, methiothepin halved the number of high-affinity binding sites and decreased their affinity. 4. h5-HT(1B) receptor-mediated Galpha(i3) subunit activation was dependent on the concentration of NaCl. At 300 mM, 5-HT stimulated [(35)S]GTPgammaS binding, basal Galpha(i3) activation was low and methiothepin was inactive. In contrast, at 10 mM NaCl, basal activity was enhanced and the inverse agonist activity of methiothepin was accentuated. Under these conditions, 5-HT decreased Galpha(i3) activation. 5. In conclusion, at h5-HT(1B) receptors expressed in CHO cells: (i) inverse agonist induced inhibition of Galpha(i3), and its reversal by S18127, reveals constitutive activation of this Galpha subunit; (ii) constitutive Galpha(i3) activation can be quantified by isotopic dilution [(35)S]GTPgammaS binding and (iii) decreasing NaCl concentrations enhances Galpha(i3) activation and leads to protean agonist properties of 5-HT: that is a switch to inhibition of Galpha(i3).

  13. Reference measurement procedure for total glycerides by isotope dilution GC-MS.

    PubMed

    Edwards, Selvin H; Stribling, Shelton L; Pyatt, Susan D; Kimberly, Mary M

    2012-04-01

    The CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing. The CA RMP has several disadvantages, including lack of ruggedness. It uses obsolete instrumentation and hazardous reagents. To overcome these problems the CDC developed an isotope dilution GC-MS (ID-GC-MS) RMP for total glycerides in serum. We diluted serum samples with Tris-HCl buffer solution and spiked 200-μL aliquots with [(13)C(3)]-glycerol. These samples were incubated and hydrolyzed under basic conditions. The samples were dried, derivatized with acetic anhydride and pyridine, extracted with ethyl acetate, and analyzed by ID-GC-MS. Linearity, imprecision, and accuracy were evaluated by analyzing calibrator solutions, 10 serum pools, and a standard reference material (SRM 1951b). The calibration response was linear for the range of calibrator concentrations examined (0-1.24 mmol/L) with a slope and intercept of 0.717 (95% CI, 0.7123-0.7225) and 0.3122 (95% CI, 0.3096-0.3140), respectively. The limit of detection was 14.8 μmol/L. The mean %CV for the sample set (serum pools and SRM) was 1.2%. The mean %bias from NIST isotope dilution MS values for SRM 1951b was 0.7%. This ID-GC-MS RMP has the specificity and ruggedness to accurately quantify total glycerides in the serum pools used in the CDC's Lipid Standardization Program and demonstrates sufficiently acceptable agreement with the NIST primary RMP for total glyceride measurement.

  14. Effect of dilution in sperm maturation media and time of storage on sperm motility and fertilizing capacity of cryopreserved semen of sex-reversed female rainbow trout.

    PubMed

    Judycka, Sylwia; Ciereszko, Andrzej; Dobosz, Stefan; Zalewski, Tomasz; Dietrich, Grzegorz J

    2017-05-01

    Masculinized females, also called neomales or sex-reversed females have a male phenotype but retain the female genotype (XX). Therefore, all spermatozoa produced in their functional testes carry an X chromosome, which is desired for the production of all-female rainbow trout populations. Semen of sex-reversed female rainbow trout is of low quality and in vitro maturation is required, which includes dilution of sperm suspensions with specially formulated maturation solutions. The aim of this study was to determine the effect of dilution in different maturation media on sperm quality (sperm motility characteristics and fertilizing capacity) of frozen/thawed sperm of sex-reversed female rainbow trout. The effect of time of post-thaw storage (0, 15, 60 and 120min) on semen quality was also tested. Sperm motility parameters and fertilization rate at the eyed and hatching stages were assessed for post-thaw semen diluted in different media. The cryopreservation procedure resulted in high post-thaw sperm motility of about 57% and did not differ from fresh semen. Unexpectedly, maturation media decreased sperm activation capacity immediately after dilution; however, sperm motility increased over time. Fertilization rates of frozen/thawed semen were high (71-87%) and did not differ significantly between experimental variants at any of tested periods of storage. Our results demonstrated that the effect of the maturation media on frozen/thawed sperm is different from that of fresh sperm. The progressive increase in post-thaw sperm motility in maturation media can potentially be applied to routine hatchery practice. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Predicting the solubility and lability of Zn, Cd, and Pb in soils from a minespoil-contaminated catchment by stable isotopic exchange

    NASA Astrophysics Data System (ADS)

    Marzouk, E. R.; Chenery, S. R.; Young, S. D.

    2013-12-01

    The Rookhope catchment of Weardale, England, has a diverse legacy of contaminated soils due to extensive lead mining activity over four centuries. We measured the isotopically exchangeable content of Pb, Cd and Zn (E-values) in a large representative subset of the catchment soils (n = 246) using stable isotope dilution. All three metals displayed a wide range of %E-values (c. 1-100%) but relative lability followed the sequence Cd > Pb > Zn. A refinement of the stable isotope dilution approach also enabled detection of non-reactive metal contained within suspended sub-micron (<0.22 μm) colloidal particles (SCP-metal). For most soils, the presence of non-labile SCP-metal caused only minor over-estimation of E-values (<2%) but the effect was greater for soils with particularly large humus or carbonate contents. Approximately 80%, 53% and 66% of the variability in Zn, Cd and Pb %E-values (respectively) could be explained by pH, loss on ignition and total metal content. E-values were affected by the presence of ore minerals at high metal contents leading to an inconsistent trend in the relationship between %E-value and soil metal concentration. Metal solubility, in the soil suspensions used to measure E-values, was predicted using the WHAM geochemical speciation model (versions VI and VII). The use of total and isotopically exchangeable metal as alternative input variables was compared; the latter provided significantly better predictions of solubility, especially in the case of Zn. Lead solubility was less well predicted by either version of WHAM, with over-prediction at low pH and under-prediction at high soil pH values. Quantify the isotopically exchangeable fractions of Zn, Cd and Pb (E-values), and assess their local and regional variability, using multi-element stable isotope dilution, in a diverse range of soil ecosystems within the catchment of an old Pb/Zn mining area. Assess the controlling influences of soil properties on metal lability and develop predictive algorithms for metal lability in the contaminated catchment based on simple soil properties (such as pH, organic matter (LOI), and total metal content). Examine the incidence of non-isotopically-exchangeable metal held within suspended colloidal particles (SCP-metal) in filtered soil solutions (<0.22 μm) by comparing E-values from isotopic abundance in solutions equilibrated with soil and in a resin phase equilibrated with the separated solution. Assess the ability of a geochemical speciation model, WHAM(VII), to predict metal solubility using isotopically exchangeable metal as an input variable.

  16. Application and validation of isotope dilution method (IDM) for predicting bioavailability of hydrophobic organic contaminants in soil.

    PubMed

    Wang, Jie; Taylor, Allison; Schlenk, Daniel; Gan, Jay

    2018-05-01

    Risk assessment of hydrophobic organic contaminants (HOCs) using the total chemical concentration following exhaustive extraction may overestimate the actual availability of HOCs to non-target organisms. Existing methods for estimating HOC bioavailability in soil have various operational limitations. In this study, we explored the application of isotope dilution method (IDM) to quantify the accessible fraction (E) of DDTs and PCBs in both historically-contaminated and freshly-spiked soils. After addition of 13 C or deuterated analogues to a soil sample, the phase distribution of isotope-labeled and native chemicals reached an apparent equilibrium within 48 h of mixing. The derived E values in the three soils ranged from 0.19 to 0.82, depending on the soil properties and also the contact time of HOCs (i.e., aging). The isotope dilution method consistently predicted greater accumulation into earthworm (Eisenia fetida) than that by polyethylene (PE) or solid phase microextraction (SPME) sampler, likely because desorption in the gut enhanced bioavailability of soil-borne HOCs. A highly significant linear regression (R 2  = 0.91) was found between IDM and 24-h Tenax desorption, with a slope statistically identical to 1. The IDM-derived accessible concentration (C e ) was further shown to accurately predict tissue residues in earthworm exposed in the same soils. Given the relatively short duration and simple steps, IDM has the potential to be readily adopted for measuring HOC bioaccessibility in soil and for improving risk assessment and evaluation of remediation efficiency. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Gravitational effects on plant growth hormone concentration

    NASA Technical Reports Server (NTRS)

    Bandurski, R. S.; Schulze, A.

    1983-01-01

    Dolk's (1936) finding that more growth hormone diffuses from the lower side of a gravity-stimulated plant shoot than from the upper side is presently confirmed by means of both an isotope dilution assay and selected ion monitoring-gas chromatography-mass spectrometry, and it is established that the asymmetrically distributed hormone is indole-3-acetic acid (IAA). This is the first physicochemical demonstration that there is more IAA on the lower sides of a geostimulated plant shoot. It is also found that free IAA primarily occurs in the conductive vascular tissues of the shoot, while IAA esters predominate in the growing cortical cells. A highly sensitive gas chromatographic isotope dilution assay shows that the hormone asymmetry also occurs in the nonvascular tissue.

  18. Uranium Measurement Improvements at the Savannah River Technology Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shick, C. Jr.

    Uranium isotope ratio and isotope dilution methods by mass spectrometry are used to achieve sensitivity, precision and accuracy for various applications. This report presents recent progress made at SRTC in the analysis of minor isotopes of uranium. Comparison of routine measurements of NBL certified uranium (U005a) using the SRTC Three Stage Mass Spectrometer (3SMS) and the SRTC Single Stage Mass Spectrometer (SSMS). As expected, the three stage mass spectrometer yielded superior sensitivity, precision, and accuracy for this application.

  19. Current capabilities and limitations of the stable isotope technologies and applied mathematical equations in determining whole body vitamin A status

    USDA-ARS?s Scientific Manuscript database

    Vitamin A (VA) stable isotope dilution methodology provides a quantitative estimate of total body VA stores and is the best method currently available for assessing VA status in adults and children. The methodology has also been used to test the efficacy of VA interventions in a number of low-incom...

  20. High-accuracy measurements of N2O concentration and site-specific nitrogen isotopes in small or high concentration samples

    NASA Astrophysics Data System (ADS)

    Palmer, M. R.; Arata, C.; Huang, K.

    2014-12-01

    Nitrous oxide (N2O) gas is among the major contributors to global warming and ozone depletion in stratosphere. Quantitative estimate of N­2O production in various pathways and N­2O fluxes across different reservoirs is the key to understanding the role of N­2O in the global change. To achieve this goal, accurate and concurrent measurement of both N2O concentration ([N2O]) and its site-specific isotopic composition (SP-δ15N), namely δ15Nα and δ15Nβ, is desired. Recent developments in Cavity Ring-Down Spectroscopy (CRDS) have enabled high precision measurements of [N2O] and SP-δ15N of a continuous gas flow. However, many N­­2O samples are discrete with limited volume (< 500 ml), and/or high [N2O] (> 2 ppm), and are not suitable for direct measurements by CRDS. Here we present results of a Small Sample Isotope Module 2 (SSIM2) which is coupled to and automatically coordinated with a Picarro isotopic N2O CRDS analyzer to handle and measure high concentration and/or small volume samples. The SSIM2 requires 20 ml of sample per analysis, and transfers the sample to the CRDS for high precision measurement. When the sample injection is < 20 ml, a zero gas is optionally filled to make up the volume. We used the SSIM2 to dilute high [N2O] samples and < 20 ml samples, and tested the effect of dilution on the measured SP-δ15N. In addition, we employed and tested a newly developed double injection method for samples adequate for two 20 ml injections. After the SSIM2 and the CRDS cavity was primed with the first injection, the second injection, which has negligible dilution of the sample, can be accurately measured for both [N2O] and SP-δ15N. Results of these experiments indicate that the precision of SSIM2-CRDS is similar to that of the continuous measurements using the CRDS alone, and that dilution has minimal effect on SP-δ15N, as along as the [N2O] is > 300 ppb after dilution. Overall, the precision of SP-δ15N measured using the SSIM2 is < 0.5 ‰.

  1. Development and Interlaboratory Study of a Liquid Chromatography Tandem Mass Spectrometric Methodfor the Determination of Multiple Mycotoxins inCereals Using Stable Isotope Dilution.

    PubMed

    Ye, Jin; Wu, Yu; Guo, Qilei; Lu, Meiling; Wang, Songshan; Xin, Yuanyuan; Xie, Gang; Zhang, Yan; Mariappan, Meena; Wang, Songxue

    2018-05-01

    An efficient, rapid, accurate, and cost-effective method based on stable isotope dilution and LC tandem MS was developed for the determination of multimycotoxins in cereals. The samples were extracted using acetonitrile-water-acetic acid (70 + 29 + 1, v/v/v), followed by dilution and centrifugation without any further cleanup. The mycotoxins were separated on a C18 column. Interference due to matrix effects was efficiently compensated for with [13C]-labeled stable isotope internal standards. The method demonstrated excellent linear relations, with regression coefficients above 0.999. Spiked recoveries at three different concentrations ranged from 80.9 to 115.9%, and RSDs were below 14% for all mycotoxins. The trueness of the method was also verified by participating in two proficiency tests, and satisfactory z-scores (|z| < 1.1) were obtained. In addition, an international interlaboratory study was organized to evaluate the methods. Eight laboratories characterized recovery, repeatability, and reproducibility studies in wheat, maize, and barley. The interlaboratory results were analyzed according to ISO 5725-2. Cochran and Grubbs tests were used to remove outliers. The mean recoveries of all 16 mycotoxins ranged from 87 to 111%. Repeatability, reproducibility, and Horwitz ratio values were 3.5-16.2, 5.4-33.6, and 0.16-1.65%, respectively. The results demonstrate that the method is reliable to determine multimycotoxins in cereals.

  2. Validation of highly sensitive simultaneous targeted and untargeted analysis of keto-steroids by Girard P derivatization and stable isotope dilution-liquid chromatography-high resolution mass spectrometry.

    PubMed

    Frey, Alexander J; Wang, Qingqing; Busch, Christine; Feldman, Daniel; Bottalico, Lisa; Mesaros, Clementina A; Blair, Ian A; Vachani, Anil; Snyder, Nathaniel W

    2016-12-01

    A multiplexed quantitative method for the analysis of three major unconjugated steroids in human serum by stable isotope dilution liquid chromatography-high resolution mass spectrometry (LC-HRMS) was developed and validated on a Q Exactive Plus hybrid quadrupole/Orbitrap mass spectrometer. This quantification utilized isotope dilution and Girard P derivatization on the keto-groups of testosterone (T), androstenedione (AD) and dehydroepiandrosterone (DHEA) to improve ionization efficiency using electrospray ionization. Major isomeric compounds to T and DHEA; the inactive epimer of testosterone (epiT), and the metabolite of AD, 5α-androstanedione (5α-AD) were completely resolved on a biphenyl column within an 18min method. Inter- and intra-day method validation using LC-HRMS with qualifying product ions was performed and acceptable analytical performance was achieved. The method was further validated by comparing steroid levels from 100μL of serum from young vs older subjects. Since this approach provides high-dimensional HRMS data, untargeted analysis by age group was performed. DHEA and T were detected among the top analytes most significantly different across the two groups after untargeted LC-HRMS analysis, as well as a number of other still unknown metabolites, indicating the potential for combined targeted/untargeted analysis in steroid analysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Isotope Dilution-Based Targeted and Nontargeted Carbonyl Neurosteroid/Steroid Profiling.

    PubMed

    Sharp, Sheila; Mitchell, Scott J; Vallée, Monique; Kuzmanova, Elena; Cooper, Michelle; Belelli, Delia; Lambert, Jeremy J; Huang, Jeffrey T-J

    2018-04-17

    Neurosteroids are brain-derived steroids, capable of rapidly modulating neuronal excitability in a nongenomic manner. Dysregulation of their synthesis or metabolism has been implicated in many pathological conditions. Here, we describe an isotope dilution based targeted and nontargeted (ID-TNT) profiling of carbonyl neurosteroids/steroids. The method combines stable isotope dilution, hydroxylamine derivatization, high-resolution MS scanning, and data-dependent MS/MS analysis, allowing absolute quantification of pregnenolone, progesterone, 5α-dihydroprogesterone, 3α,5α-tetrahydroprogesterone, and 3β,5α-tetrahydroprogesterone, and relative quantification of other carbonyl containing steroids. The utility and validity of this approach was tested in an acute stress mouse model and via pharmacological manipulation of the steroid metabolic pathway with finasteride. We report that brain levels of 3α,5α-tetrahydroprogesterone, a potent enhancer of GABA A receptor (GABA A R-mediated inhibitory function, from control mice is in the 5-40 pmol/g range, a value greater than previously reported. The approach allows the use of data from targeted analysis to guide the normalization strategy for nontargeted data. Furthermore, novel findings, including a striking increase of brain pregnenolone following finasteride administration were discovered in this study. Collectively, our results indicate that this approach has distinct advantages for examining targeted and nontargeted neurosteroid/steroid pathways in animal models and could facilitate a better understanding of the physiological and pathological roles of neurosteroids as modulators of brain excitability.

  4. Simultaneous quantification of endogenous and exogenous plasma glucose by isotope dilution LC-MS/MS with indirect MRM of the derivative tag.

    PubMed

    Yu, Lingling; Wen, Chao; Li, Xing; Fang, Shiqi; Yang, Lichuan; Wang, Tony; Hu, Kaifeng

    2018-03-01

    Quantification of endogenous and exogenous plasma glucose can help more comprehensively evaluate the glucose metabolic status. A ratio-based approach using isotope dilution liquid chromatography tandem mass spectrometry (ID LC-MS/MS) with indirect multiple reaction monitoring (MRM) of the derivative tag was developed to simultaneously quantify endo-/exogenous plasma glucose. Using diluted D-[ 13 C 6 ] glucose as tracer of exogenous glucose, 12 C 6 / 13 C 6 glucoses were first derivatized and then data were acquired in MRM mode. The metabolism of exogenous glucose can be tracked and the concentration ratio of endo/exo-genous glucose can be measured by calculating the endo-/exo-genous glucose concentrations from peak area ratio of specific daughter ions. Joint application of selective derivatization and MRM analysis not only improves the sensitivity but also minimizes the interference from the background of plasma, which warrants the accuracy and reproducibility. Good agreement between the theoretical and calculated concentration ratios was obtained with a linear correlation coefficient (R) of 0.9969 in the range of D-glucose from 0.5 to 20.0 mM, which covers the healthy and diabetic physiological scenarios. Satisfactory reproducibility was obtained by evaluation of the intra- and inter-day precisions with relative standard deviations (RSDs) less than 5.16%, and relative recoveries of 85.96 to 95.92% were obtained at low, medium, and high concentration, respectively. The method was successfully applied to simultaneous determination of the endo-/exogenous glucose concentration in plasma of non-diabetic and type II diabetic cynomolgus monkeys. Graphical Abstract The scheme of the proposed ratio-based approach using isotope dilution LC-MS/MS with indirect MRM of the derivative tag for simultaneous quantification of endogenous and exogenous plasma glucose.

  5. Impact of different dilution techniques on boar sperm quality and sperm distribution of the extended ejaculate.

    PubMed

    Schulze, M; Ammon, C; Schaefer, J; Luther, A-M; Jung, M; Waberski, D

    2017-07-01

    The dilution of ejaculates is a fundamental step for the production of liquid-preserved boar semen. For a long time, it has been recommended to add the extender to the ejaculate. The aim of the present study was to first compare the effect of the position ('center' vs. 'wall') where the extender is added to the semen-mixing cylinder (height 32.5cm; diameter 12.7cm) using an automatic dispenser (n=11). In experiment 2 (n=30), we analyzed the two main dilution methods (extender to the semen ('control') vs. 'reverse'). Experiment 3 was carried out to study the dilution effect on kinematics. In Experiments 1 and 2, the sperm distribution 10min after the dilution and the sperm quality parameters during long-term storage (d1, d3, d5, and d7) were evaluated. In Experiment 3, sperm quality was assessed during short-term storage at 0, 10, 20, 30 and 60min after semen dilution ('control' vs. 'reverse'; n=6). There were no significant differences (P>0.05) between the treatments in the specific response to bicarbonate, mitochondrial activity, membrane status, thermo-resistance or sperm motility immediately after dilution or long-term storage. The sperm distribution was significantly (P=0.029) affected by the dilution method in Experiment 2. In summary, treatment with the extender first, which is used by only a few European boar studs, leads to comparable results in sperm quality during storage and better results in sperm distribution after dilution. This procedure is also less time consuming, less foam formation occurs during the semen dilution and the procedure is more hygienic. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. On-line double isotope dilution laser ablation inductively coupled plasma mass spectrometry for the quantitative analysis of solid materials.

    PubMed

    Fernández, Beatriz; Rodríguez-González, Pablo; García Alonso, J Ignacio; Malherbe, Julien; García-Fonseca, Sergio; Pereiro, Rosario; Sanz-Medel, Alfredo

    2014-12-03

    We report on the determination of trace elements in solid samples by the combination of on-line double isotope dilution and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). The proposed method requires the sequential analysis of the sample and a certified natural abundance standard by on-line IDMS using the same isotopically-enriched spike solution. In this way, the mass fraction of the analyte in the sample can be directly referred to the certified standard so the previous characterization of the spike solution is not required. To validate the procedure, Sr, Rb and Pb were determined in certified reference materials with different matrices, including silicate glasses (SRM 610, 612 and 614) and powdered samples (PACS-2, SRM 2710a, SRM 1944, SRM 2702 and SRM 2780). The analysis of powdered samples was carried out both by the preparation of pressed pellets and by lithium borate fusion. Experimental results for the analysis of powdered samples were in agreement with the certified values for all materials. Relative standard deviations in the range of 6-21% for pressed pellets and 3-21% for fused solids were obtained from n=3 independent measurements. Minimal sample preparation, data treatment and consumption of the isotopically-enriched isotopes are the main advantages of the method over previously reported approaches. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Investigations of interhydrogen bond dynamical coupling effects in the polarized IR spectra of acetanilide crystals.

    PubMed

    Flakus, Henryk T; Michta, Anna

    2010-02-04

    This Article presents the investigation results of the polarized IR spectra of the hydrogen bond in acetanilide (ACN) crystals measured in the frequency range of the proton and deuteron stretching vibration bands, nu(N-H) and nu(N-D). The basic spectral properties of the crystals were interpreted quantitatively in terms of the "strong-coupling" theory. The model of the centrosymmetric dimer of hydrogen bonds postulated by us facilitated the explanation of the well-developed, two-branch structure of the nu(N-H) and nu(N-D) bands as well as the isotopic dilution effects in the spectra. On the basis of the linear dichroic and temperature effects in the polarized IR spectra of ACN crystals, the H/D isotopic "self-organization" effects were revealed. A nonrandom distribution of hydrogen isotope atoms (H or D) in the lattice was deduced from the spectra of isotopically diluted ACN crystals. It was also determined that identical hydrogen isotope atoms occupy both hydrogen bonds in the dimeric systems, where each hydrogen bond belongs to a different chain. A more complex fine structure pattern of nu(N-H) and nu(N-D) bands in ACN spectra in comparison with the spectra of other secondary amides (e.g., N-methylacetamide) can be explained in terms of the "relaxation" theory of the IR spectra of hydrogen-bonded systems.

  8. Distribution of the hallucinogens N,N-dimethyltryptamine and 5-methoxy-N,N-dimethyltryptamine in rat brain following intraperitoneal injection: application of a new solid-phase extraction LC-APcI-MS-MS-isotope dilution method.

    PubMed

    Barker, S A; Littlefield-Chabaud, M A; David, C

    2001-02-10

    A method for the solid-phase extraction (SPE) and liquid chromatographic-atmospheric pressure chemical ionization-mass spectrometric-mass spectrometric-isotope dilution (LC-APcI-MS-MS-ID) analysis of the indole hallucinogens N,N-dimethyltryptamine (DMT) and 5-methoxy DMT (or O-methyl bufotenin, OMB) from rat brain tissue is reported. Rats were administered DMT or OMB by the intraperitoneal route at a dose of 5 mg/kg and sacrificed 15 min post treatment. Brains were dissected into discrete areas and analyzed by the methods described as a demonstration of the procedure's applicability. The synthesis and use of two new deuterated internal standards for these purposes are also reported.

  9. Determination of urea kinetics by isotope dilution with [13C]urea and gas chromatography-isotope ratio mass spectrometry (GC-IRMS) analysis.

    PubMed

    Kloppenburg, W D; Wolthers, B G; Stellaard, F; Elzinga, H; Tepper, T; de Jong, P E; Huisman, R M

    1997-07-01

    1. Stable urea isotopes can be used to study urea kinetics in humans. The use of stable urea isotopes for studying urea kinetic parameters in humans on a large scale is hampered by the high costs of the labelled material. We devised a urea dilution for measurement of the distribution volume, production rate and clearance of urea in healthy subjects and renal failure patients using the inexpensive single labelled [13C]urea isotope with subsequent analysis by headspace chromatography-isotope ratio MS (GC-IRMS) of the [13C]urea enrichment. 2. The method involves measurement of the molar percentage excess of [13C]urea in plasma samples taken over a 4 h period after an intravenous bolus injection of [13C]urea. During the sample processing procedure, the plasma samples together with calibration samples containing a known molar percentage excess of [13C]urea are acidified with phosphoric acid to remove endogenous CO2, and are subsequently incubated with urease to convert the urea present in the plasma samples into CO2. The 13C enrichment of the generated CO2 is analysed by means of GC-IRMS. This method allows measurement of the molar percentage excess of [13C]urea to an accuracy of 0.02%. 3. Reproducibility studies showed that the sample processing procedure [within-run coefficient of variation (CV) < 2.8% and between-run CV < 8.8%] and the GC-IRMS analysis (within-day CV < 1.3% and between-day CV < 1.3%) could be repeated with good reproducibility. 4. In clinical urea kinetic studies in a healthy subject and in a renal failure patient without residual renal function, reproducible values of the distribution volume, production rate and clearance of urea were determined using minimal amounts of [13C]urea (25-50 mg). 5. Because only low [13C]urea enrichments are needed in this urea dilution method using GC-IRMS analysis, the costs of urea kinetic studies are reduced considerably, especially in patients with renal failure.

  10. A double-spike method for K-Ar measurement: A technique for high precision in situ dating on Mars and other planetary surfaces

    NASA Astrophysics Data System (ADS)

    Farley, K. A.; Hurowitz, J. A.; Asimow, P. D.; Jacobson, N. S.; Cartwright, J. A.

    2013-06-01

    A new method for K-Ar dating using a double isotope dilution technique is proposed and demonstrated. The method is designed to eliminate known difficulties facing in situ dating on planetary surfaces, especially instrument complexity and power availability. It may also have applicability in some terrestrial dating applications. Key to the method is the use of a solid tracer spike enriched in both 39Ar and 41K. When mixed with lithium borate flux in a Knudsen effusion cell, this tracer spike and a sample to be dated can be successfully fused and degassed of Ar at <1000 °C. The evolved 40Ar∗/39Ar ratio can be measured to high precision using noble gas mass spectrometry. After argon measurement the sample melt is heated to a slightly higher temperature (˜1030 °C) to volatilize potassium, and the evolved 39K/41K ratio measured by Knudsen effusion mass spectrometry. Combined with the known composition of the tracer spike, these two ratios define the K-Ar age using a single sample aliquot and without the need for extreme temperature or a mass determination. In principle the method can be implemented using a single mass spectrometer. Experiments indicate that quantitative extraction of argon from a basalt sample occurs at a sufficiently low temperature that potassium loss in this step is unimportant. Similarly, potassium isotope ratios measured in the Knudsen apparatus indicate good sample-spike equilibration and acceptably small isotopic fractionation. When applied to a flood basalt from the Viluy Traps, Siberia, a K-Ar age of 351 ± 19 Ma was obtained, a result within 1% of the independently known age. For practical reasons this measurement was made on two separate mass spectrometers, but a scheme for combining the measurements in a single analytical instrument is described. Because both parent and daughter are determined by isotope dilution, the precision on K-Ar ages obtained by the double isotope dilution method should routinely approach that of a pair of isotope ratio determinations, likely better than ±5%.

  11. Determination of agmatine using isotope dilution UPLC-tandem mass spectrometry: application to the characterization of the arginine decarboxylase pathway in Pseudomonas aeruginosa.

    PubMed

    Dalluge, Joseph J; McCurtain, Jennifer L; Gilbertsen, Adam J; Kalstabakken, Kyle A; Williams, Bryan J

    2015-07-01

    A method has been developed for the direct determination of agmatine in bacterial culture supernatants using isotope dilution ultra performance liquid chromatography (UPLC)-tandem mass spectrometry (UPLC-MS/MS). Agmatine determination in bacterial supernatants is comprised of spiking culture or isolate supernatants with a fixed concentration of uniformly labeled (13)C5,(15)N4-agmatine (synthesized by decarboxylation of uniformly labeled (13)C6,(15)N4-arginine using arginine decarboxylase from Pseudomonas aeruginosa) as an internal standard, followed by derivatization with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBDF) to improve the reversed-phase chromatographic retention characteristics of agmatine, as well as the selectivity and sensitivity of UPLC-MS/MS detection of this amine in complex biologically derived mixtures. Intrasample precisions for measurement of agmatine in culture supernatants average 4.1% (relative standard deviation). Calibration curves are linear over the range 5 nM to 10 μM, and the detection limit is estimated at 1.5 nM. To demonstrate the utility of the method, agmatine levels in supernatants of overnight cultures of wild-type (UCBPP-PA14), as well as arginine decarboxylase and agmatine deiminase mutant strains of P. aeruginosa strain UCBPP-PA14 were measured. This method verified that the mutant strains are lacking the specific metabolic capabilities to produce and metabolize agmatine. In addition, measurement of agmatine in supernatants of a panel of clinical isolates from patients with cystic fibrosis revealed that three of the P. aeruginosa isolates hyper-secreted agmatine into the supernatant, hypothesized to be a result of a mutation in the aguA gene. Because agmatine has potential inflammatory activities in the lung, this phenotype may be a virulence factor for P. aeruginosa in the lung environment of cystic fibrosis patients.

  12. Determination of agmatine using isotope dilution UPLC-tandem mass spectrometry: application to the characterization of the arginine decarboxylase pathway in Pseudomonas aeruginosa

    PubMed Central

    McCurtain, Jennifer L.; Gilbertsen, Adam J.; Kalstabakken, Kyle A.; Williams, Bryan J.

    2018-01-01

    A method has been developed for the direct determination of agmatine in bacterial culture supernatants using isotope dilution ultra performance liquid chromatography (UPLC)-tandem mass spectrometry (UPLC-MS/MS). Agmatine determination in bacterial supernatants is comprised of spiking culture or isolate supernatants with a fixed concentration of uniformly labeled 13C5,15N4-agmatine (synthesized by decarboxylation of uniformly labeled 13C6,15N4-arginine using arginine decarboxylase from Pseudomonas aeruginosa) as an internal standard, followed by derivatization with 4-fluoro-7-nitro-2,l,3-benzoxadiazole (NBDF) to improve the reversed-phase chromatographic retention characteristics of agmatine, as well as the selectivity and sensitivity of UPLC-MS/MS detection of this amine in complex biologically derived mixtures. Intrasample precisions for measurement of agmatine in culture supernatants average 4.1 % (relative standard deviation). Calibration curves are linear over the range 5 nM to 10 μM, and the detection limit is estimated at 1.5 nM. To demonstrate the utility of the method, agmatine levels in supernatants of overnight cultures of wild-type (UCBPP-PA14), as well as arginine decarboxylase and agmatine deiminase mutant strains of P. aeruginosa strain UCBPP-PA14 were measured. This method verified that the mutant strains are lacking the specific metabolic capabilities to produce and metabolize agmatine. In addition, measurement of agmatine in supernatants of a panel of clinical isolates from patients with cystic fibrosis revealed that three of the P. aeruginosa isolates hyper-secreted agmatine into the supernatant, hypothesized to be a result of a mutation in the aguA gene. Because agmatine has potential inflammatory activities in the lung, this phenotype may be a virulence factor for P. aeruginosa in the lung environment of cystic fibrosis patients. PMID:25957842

  13. A reversible dendrite-free high-areal-capacity lithium metal electrode

    PubMed Central

    Wang, Hui; Matsui, Masaki; Kuwata, Hiroko; Sonoki, Hidetoshi; Matsuda, Yasuaki; Shang, Xuefu; Takeda, Yasuo; Yamamoto, Osamu; Imanishi, Nobuyuki

    2017-01-01

    Reversible dendrite-free low-areal-capacity lithium metal electrodes have recently been revived, because of their pivotal role in developing beyond lithium ion batteries. However, there have been no reports of reversible dendrite-free high-areal-capacity lithium metal electrodes. Here we report on a strategy to realize unprecedented stable cycling of lithium electrodeposition/stripping with a highly desirable areal-capacity (12 mAh cm−2) and exceptional Coulombic efficiency (>99.98%) at high current densities (>5 mA cm−2) and ambient temperature using a diluted solvate ionic liquid. The essence of this strategy, that can drastically improve lithium electrodeposition kinetics by cyclic voltammetry premodulation, lies in the tailoring of the top solid-electrolyte interphase layer in a diluted solvate ionic liquid to facilitate a two-dimensional growth mode. We anticipate that this discovery could pave the way for developing reversible dendrite-free metal anodes for sustainable battery chemistries. PMID:28440299

  14. Improvements in Cd stable isotope analysis achieved through use of liquid-liquid extraction to remove organic residues from Cd separates obtained by extraction chromatography.

    PubMed

    Murphy, Katy; Rehkämper, Mark; Kreissig, Katharina; Coles, Barry; van de Flierdt, Tina

    2016-01-23

    Organic compounds released from resins that are commonly employed for trace element separations are known to have a detrimental impact on the quality of isotopic analyses by MC-ICP-MS. A recent study highlighted that such effects can be particularly problematic for Cd stable isotope measurements (M. Gault-Ringold and C. H. Stirling, J. Anal. At. Spectrom. , 2012, 27 , 449-459). In this case, the final stage of sample purification commonly applies extraction chromatography with Eichrom TRU resin, which employs particles coated with octylphenyl- N , N -di-isobutyl carbamoylphosphine oxide (CMPO) dissolved in tri- n -butyl phosphate (TBP). During chromatography, it appears that some of these compounds are eluted alongside Cd and cannot be removed by evaporation due to their high boiling points. When aliquots of the zero-ε reference material were processed through the purification procedure, refluxed in concentrated HNO 3 and analyzed at minimum dilution (in 1 ml 0.1 M HNO 3 ), they yielded Cd isotopic compositions (ε 114/110 Cd = 4.6 ± 3.4, 2SD, n = 4) that differed significantly from the expected value, despite the use of a double spike technique to correct for instrumental mass fractionation. This result was accompanied by a 35% reduction in instrumental sensitivity for Cd. With increasing dilution of the organic resin residue, both of these effects are reduced and they are insignificant when the eluted Cd is dissolved in ≥3 ml 0.1 M HNO 3 . Our results, furthermore, indicate that the isotopic artefacts are most likely related to anomalous mass bias behavior. Previous studies have shown that perchloric acid can be effective at avoiding such effects (Gault-Ringold and Stirling, 2012; K. C. Crocket, M. Lambelet, T. van de Flierdt, M. Rehkämper and L. F. Robinson, Chem. Geol. , 2014, 374-375 , 128-140), presumably by oxidizing the resin-derived organics, but there are numerous disadvantages to its use. Here we show that liquid-liquid extraction with n -heptane removes the organic compounds, dramatically improving quality of the Cd isotope data for samples that are analyzed at or close to minimum dilution factors. This technique is quick, simple and may be of use prior to analysis of other isotope systems where similar resins are employed.

  15. Rapid and highly reproducible analysis of rare earth elements by multiple collector inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Baker, Joel; Waight, Tod; Ulfbeck, David

    2002-10-01

    A method has been developed for the rapid chemical separation and highly reproducible analysis of the rare earth elements (REE) by isotope dilution analysis by means of a multiple collector inductively coupled plasma mass spectrometer (MC-ICP-MS). This technique is superior in terms of the analytical reproducibility or rapidity of analysis compared with quadrupole ICP-MS or with thermal ionization mass spectrometric isotope dilution techniques. Samples are digested by standard hydrofluoric-nitric acid-based techniques and spiked with two mixed spikes. The bulk REE are separated from the sample on a cation exchange column, collecting the middle-heavy and light REE as two groups, which provides a middle-heavy REE cut with sufficient separation of the light from the heavier REE to render oxide interferences trivial, and a Ba-free light REE cut. The heavy (Er-Lu), middle (Eu-Gd), and light REE (La-Eu) concentrations are determined by three short (1 to 2 min) analyses with a CETAC Aridus desolvating nebulizer introduction system. Replicate digestions of international rock standards demonstrate that concentrations can be reproduced to <1%, which reflects weighing errors during digestion and aliquotting as inter-REE ratios reproduce to ≤0.2% (2 SD). Eu and Ce anomalies reproduce to <0.15%. In addition to determining the concentrations of polyisotopic REE by isotope dilution analysis, the concentration of monoisotopic Pr can be measured during the light REE isotope dilution run, by reference to Pr/Ce and Pr/Nd ratios measured in a REE standard solution. Pr concentrations determined in this way reproduce to <1%, and Pr/REE ratios reproduce to <0.4%. Ce anomalies calculated with La and Pr also reproduce to <0.15% (2 SD). The precise Ce (and Eu) anomaly measurements should allow greater use of these features in studying the recycling of materials with these anomalies into the mantle, or redox-induced effects on the REE during recycling and dehydration of oceanic lithosphere, partial melting, metamorphism, alteration, or sedimentation processes. Moreover, this technique consumes very small amounts (subnanograms) of the REE and will allow precise REE determinations to be made on much smaller samples than hitherto possible.

  16. Dilution Jet Behavior in the Turn Section of a Reverse Flow Combuster

    NASA Technical Reports Server (NTRS)

    Riddlebaugh, S. M.; Lipshitz, A.; Greber, I.

    1982-01-01

    Measurements of the temperature field produced by a single jet and a row of dilution jets issued into a reverse flow combustor are presented. The temperature measurements are presented in the form of consecutive normalized temperature profiles, and jet trajectories. Single jet trajectories were swept toward the inner wall of the turn, whether injection was from the inner or outer wall. This behavior is explained by the radially inward velocity component necessary to support irrotational flow through the turn. Comparison between experimental results and model calculations showed poor agreement due to the model's not including the radial velocity component. A widely spaced row of jets produced trajectories similar to single jets at similar test conditions, but as spacing ratio was reduced, penetration was reduced to the point where the dilution jet flow attached to the wall.

  17. Differential Phosphoprotein Profiling of Tamoxifen Response

    DTIC Science & Technology

    2010-08-01

    extent serine, glycine, histidine , methionine, valine, and tyrosine. The most common isotopes in SILAC are 13C and 15N, since they demonstrate less...Rose, K. Development of an isotope dilution assay for precise determination of insulin, C-peptide, and proinsulin levels in non- diabetic and type II... diabetic individuals with comparison to immunoassay. J. Biol. Chem., 1997, 272(19), 12513-12522. [66] Barnidge, D.R.; Dratz, E.A.; Martin, T

  18. Quantitation using a stable isotope dilution assay (SIDA) and thresholds of taste-active pyroglutamyl decapeptide ethyl esters (PGDPEs) in sake.

    PubMed

    Hashizume, Katsumi; Ito, Toshiko; Igarashi, Shinya

    2017-03-01

    A stable isotope dilution assay (SIDA) for two taste-active pyroglutamyl decapeptide ethyl esters (PGDPE1; (pGlu)LFGPNVNPWCOOC 2 H 5 , PGDPE2; (pGlu)LFNPSTNPWCOOC 2 H 5 ) in sake was developed using deuterated isotopes and high-resolution mass spectrometry. Recognition thresholds of PGDPEs in sake were estimated as 3.8 μg/L for PGDPE1 and 8.1 μg/L for PGDPE2, evaluated using 11 student panelists aged in their twenties. Quantitated concentrations in 18 commercial sake samples ranged from 0 to 27 μg/L for PGDPE1 and from 0 to 202 μg/L for PGDPE2. The maximum levels of PGDPE1 and PGDPE2 in the sake samples were approximately 8 and 25 times higher than the estimated recognition thresholds, respectively. The results indicated that PGDPEs may play significant sensory roles in the sake. The level of PGDPEs in unpasteurized sake samples decreased during storage for 50 days at 6 °C, suggesting PGDPEs may be enzymatically decomposed.

  19. Development and validation of a liquid chromatography-isotope dilution tandem mass spectrometry for determination of olanzapine in human plasma and its application to bioavailability study.

    PubMed

    Zhang, Meng-Qi; Jia, Jing-Ying; Lu, Chuan; Liu, Gang-Yi; Yu, Cheng-Yin; Gui, Yu-Zhou; Liu, Yun; Liu, Yan-Mei; Wang, Wei; Li, Shui-Jun; Yu, Chen

    2010-06-01

    A simple, reliable and sensitive liquid chromatography-isotope dilution mass spectrometry (LC-ID/MS) was developed and validated for quantification of olanzapine in human plasma. Plasma samples (50 microL) were extracted with tert-butyl methyl ether and isotope-labeled internal standard (olanzapine-D3) was used. The chromatographic separation was performed on XBridge Shield RP 18 (100 mm x 2.1 mm, 3.5 microm, Waters). An isocratic program was used at a flow rate of 0.4 m x min(-1) with mobile phase consisting of acetonitrile and ammonium buffer (pH 8). The protonated ions of analytes were detected in positive ionization by multiple reactions monitoring (MRM) mode. The plasma method, with a lower limit of quantification (LLOQ) of 0.1 ng x mL(-1), demonstrated good linearity over a range of 0.1 - 30 ng x mL(-1) of olanzapine. Specificity, linearity, accuracy, precision, recovery, matrix effect and stability were evaluated during method validation. The validated method was successfully applied to analyzing human plasma samples in bioavailability study.

  20. Application of stable isotope ratio analysis for biodegradation monitoring in groundwater

    USGS Publications Warehouse

    Hatzinger, Paul B.; Böhlke, John Karl; Sturchio, Neil C.

    2013-01-01

    Stable isotope ratio analysis is increasingly being applied as a tool to detect, understand, and quantify biodegradation of organic and inorganic contaminants in groundwater. An important feature of this approach is that it allows degradative losses of contaminants to be distinguished from those caused by non-destructive processes such as dilution, dispersion, and sorption. Recent advances in analytical techniques, and new approaches for interpreting stable isotope data, have expanded the utility of this method while also exposing complications and ambiguities that must be considered in data interpretations. Isotopic analyses of multiple elements in a compound, and multiple compounds in the environment, are being used to distinguish biodegradative pathways by their characteristic isotope effects. Numerical models of contaminant transport, degradation pathways, and isotopic composition are improving quantitative estimates of in situ contaminant degradation rates under realistic environmental conditions.

  1. Key Aroma Compounds in Lippia dulcis (Dushi Button).

    PubMed

    Schmitt, Rainer; Cappi, Michael; Pollner, Gwendola; Greger, Veronika

    2018-03-14

    An aroma extract dilution analysis (AEDA) applied on aroma extracts prepared from the edible flower Dushi Button ( Lippia dulcis) resulted in the detection of 34 odor-active compounds. The highest flavor dilution (FD) factors were determined for methyl 2-methylbutanoate, ethyl 2-methylbutanoate, 4-mercapto-4-methyl-2-pentanone, an unknown caramel-like compound, and vanillin. Quantitative measurements performed by application of stable isotope dilution assays (SIDA), followed by a calculation of odor activity values (OAVs), resulted in the revelation of 4-mercapto-4-methyl-2-pentanone, linalool, myrcene, ethyl 2-methylbutanoate, methyl 2-methylbutanoate, and ( Z)-3-hexenal as important contributors to the flavor of Dushi Buttons.

  2. Validation of an isotope dilution, ICP-MS method based on internal mass bias correction for the determination of trace concentrations of Hg in sediment cores.

    PubMed

    Ciceri, E; Recchia, S; Dossi, C; Yang, L; Sturgeon, R E

    2008-01-15

    The development and validation of a method for the determination of mercury in sediments using a sector field inductively coupled plasma mass spectrometer (SF-ICP-MS) for detection is described. The utilization of isotope dilution (ID) calibration is shown to solve analytical problems related to matrix composition. Mass bias is corrected using an internal mass bias correction technique, validated against the traditional standard bracketing method. The overall analytical protocol is validated against NRCC PACS-2 marine sediment CRM. The estimated limit of detection is 12ng/g. The proposed procedure was applied to the analysis of a real sediment core sampled to a depth of 160m in Lake Como, where Hg concentrations ranged from 66 to 750ng/g.

  3. Integrated modelling of enhanced in situ biodenitrification in a fractured aquifer: biogeochemistry and isotope geochemistry

    NASA Astrophysics Data System (ADS)

    Rodríguez-Escales, Paula; Folch, Albert; van Breukelen, Boris M.; Vidal-Gavilan, Georgina; Soler, Albert

    2014-05-01

    Enhanced in-situ biodenitrification is a feasible technology to recovery groundwater polluted by nitrates and achieves drinking water standards. Under optimum conditions, nitrate is reduced by autochthonous bacteria trough different reactions until arrive to harmless dinitrogen gas. Isotopic fractionation monitoring in field applications allows knowing the exact degree and the real scope of this technology. Using the Rayleigh equation the change in the isotope ratio of the nitrate molecule (δ15N-NO3-, δ18O-NO3-) is related to the fraction of molecules remaining as a result of biodenitrification. However, Rayleigh application at field scale is sometimes limited due to other processes involved during groundwater flow such as dispersion or adsorption and geological media heterogeneities that interferes in concentration values. Then, include isotope fractionation processes in reactive transport models is a useful tool to interpret and predict data from in-situ biodenitrification. We developed a reactive transport model of enhanced in situ application at field scale in a fractured aquifer that considers biogeochemical processes as well as isotope fractionation to enable better monitoring and management of this technology. Processes considered were: microbiological- exogenous and endogenous nitrate and sulfate respiration coupled with microbial growth and decay, geochemical reactions (precipitation of calcite) and isotopic fractionation (δ15N-NO3-; δ18O- NO3- and carbon isotope network). The 2-D simulations at field scale were developed using PHAST code. Modeling of nitrate isotope geochemistry has allowed determining the extent of biodenitrification in model domain. We have quantified which is the importance in decreasing of nitrate concentrations due to biodegradation (percentage of biodegradation, 'B%') and due to dilution process (percentage of dilution, 'D%'). On the other hand, the stable carbon isotope geochemistry has been modeled. We have considered the isotopic carbon fractionation of different carbon species involved in enhanced biodenitrification: external organic carbon, biomass, inorganic carbon (in different forms) and calcite. The inclusion of carbon isotopes in the model, which are involved in both direct (oxidation of organic carbon) and indirect (carbonate mineral interaction) processes of enhanced biodenitrification, improves the evaluation of the overall model consistency due to the central role of carbon in the reaction network.

  4. Reference measurements for total mercury and methyl mercury content in marine biota samples using direct or species-specific isotope dilution inductively coupled plasma mass spectrometry.

    PubMed

    Krata, Agnieszka; Vassileva, Emilia; Bulska, Ewa

    2016-11-01

    The analytical procedures for reference measurements of the total Hg and methyl mercury (MeHg) mass fractions at various concentration levels in marine biota samples, candidates for certified reference materials (oyster and clam Gafrarium tumidum), were evaluated. Two modes of application of isotope dilution inductively coupled plasma mass spectrometry method (ID ICP-MS), namely direct isotope dilution and species-specific isotope dilution analysis with the use of two different quantification mass spectrometry techniques were compared. The entire ID ICP-MS measurement procedure was described by mathematical modelling and the combined uncertainty of measurement results was estimated. All factors influencing the final results as well as isotopic equilibrium were systematically investigated. This included the procedural blank, the moisture content in the biota samples and all factors affecting the blend ratio measurements (instrumental background, spectral interferences, dead time and mass discrimination effects as well as the repeatability of measured isotopic ratios). Modelling of the entire measurement procedures and the use of appropriate certified reference materials enable to assure the traceability of obtained values to the International System of Units (SI): the mole or the kilogram. The total mass fraction of mercury in oyster and clam biota samples, after correction for moisture contents, was found to be: 21.1 (1.1) 10(-9) kg kg(-1) (U =5.1% relative, k=2) and 390.0 (9.4) 10(-9) kg kg(-1) (U=2.4% relative, k=2), respectively. For the determination of mercury being present as methyl mercury, the non-chromatographic separation on anion-exchange resin AG1-X8 of the blended samples was applied. The content of MeHg (as Hg) in oyster sample was found: 4.81 (24) 10(-9)kgkg(-1) (U=5.0%, k=2) and 4.84 (21) 10(-9)kgkg(-1) (U=4.3%, k=2) with the use of quadrupole (ICP QMS) or sector field (ICP SFMS) inductively coupled plasma mass spectrometers, respectively. In the case of clam sample, the concentration of MeHg (as Hg) was found to be: 61.0 (2.3) 10(-)(9)kgkg(-1) (U=3.8%, k=2) and 61.3 (2.2) 10(-)(9)kgkg(-1) (U=3.6%, k=2), respectively. The mass fractions for total Hg and MeHg determined in this study were used as a contribution of the International Atomic Energy Agency (IAEA) Environment Laboratories in the characterisation of the IAEA 461 and IAEA 470 certified reference materials. The obtained good agreement with the reference values further validated the methods developed in this study. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Radioisotope dilution analyses of geological samples using 236U and 229Th

    USGS Publications Warehouse

    Rosholt, J.N.

    1984-01-01

    The use of 236U and 229Th in alpha spectrometric measurements has some advantages over the use of other tracers and measurement techniques in isotope dilution analyses of most geological samples. The advantages are: (1) these isotopes do not occur in terrestrial rocks, (2) they have negligible decay losses because of their long half lives, (3) they cause minimal recoil contamination to surface-barrier detectors, (4) they allow for simultaneous determination of the concentration and isotopic composition of uranium and thorium in a variety of sample types, and (5) they allow for simple and constant corrections for spectral inferences, 0.5% of the 238U activity is subtracted for the contribution of 235U in the 236U peak and 1% of the 229Th activity is subtracted from the 230Th activity. Disadvantages in using 236U and 229Th are: (1) individual separates of uranium and thorium must be prepared as very thin sources for alpha spectrometry, (2) good resolution in the spectrometer system is required for thorium isotopic measurements where measurement times may extend to 300 h, and (3) separate calibrations of the 236U and 229Th spike solution with both uranium and thorium standards are required. The use of these tracers in applications of uranium-series disequilibrium studies has simplified the measurements required for the determination of the isotopic composition of uranium and thorium because of the minimal corrections needed for alpha spectral interferences. ?? 1984.

  6. Identification of an Extremely 180-Rich Presolar Silicate Grain in Acfer 094

    NASA Technical Reports Server (NTRS)

    Nguyen, A. N.; Messenger, S.

    2009-01-01

    Presolar silicate grains have been abundantly identified since their first discovery less than a decade ago [1,2,3]. The O isotopic compositions of both silicate and oxide stardust indicate the vast majority (>90%) condensed around Orich asymptotic giant branch (AGB) stars. Though both presolar phases have average sizes of 300 nm, grains larger than 1 m are extremely uncommon for presolar silicates. Thus, while numerous isotopic systems have been measured in presolar oxide grains [4], very few isotopic analyses for presolar silicates exist outside of O and Si [2,5]. And still, these measurements suffer from isotopic dilution with surrounding matrix material [6]. We conduct a search for presolar silicates in the primitive carbonaceous chondrite Acfer 094 and in some cases obtain high spatial resolution, high precision isotopic ratios.

  7. Analytical Chemistry Developmental Work Using a 243Am Solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spencer, Khalil J.; Stanley, Floyd E.; Porterfield, Donivan R.

    2015-02-24

    This project seeks to reestablish our analytical capability to characterize Am bulk material and develop a reference material suitable to characterizing the purity and assay of 241Am oxide for industrial use. The tasks associated with this phase of the project included conducting initial separations experiments, developing thermal ionization mass spectrometry capability using the 243Am isotope as an isotope dilution spike , optimizing the spike for the determination of 241Pu- 241 Am radiochemistry, and, additionally, developing and testing a methodology which can detect trace to ultra- trace levels of Pu (both assay and isotopics) in bulk Am samples .

  8. Lung microvascular transport properties measured by multiple indicator dilution methods in patients with adult respiratory distress syndrome. A comparison between patients reversing respiratory failure and those failing to reverse

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, T.R.; Bernard, G.R.; Brigham, K.L.

    1990-02-01

    We conducted indicator dilution studies on the lungs of patients in the early phases of adult respiratory distress syndrome (ARDS) to test the hypothesis that capillary permeability was increased in patients with respiratory failure. Indicator dilution studies were performed using 51Cr-erythrocytes, 125I-albumin, 14C-urea, and 3H-water as tracers. The injectate was infused as a bolus into a central venous line. Peripheral arterial blood was collected and counted for radioactivity. Mathematical analysis of the indicator curves yielded cardiac output, measures of the product of capillary permeability and surface area for urea (PS and D1/2S), the intravascular lung volume (Vv), and the extravascularmore » lung water volume (Ve). Permeability was separated from surface area by normalizing PS and D1/2S to Vv. Patients could be divided into 16 in whom blood gas determinations and radiologic criteria for ARDS were reversed and 23 in whom they were not. We examined indicator dilution and other measures of lung function in the two groups to determine whether significant differences in microvascular function existed. PS and PS/Vv were significantly higher in the nonreversal patients. Ve was above normal, but not different between groups. Linear regression analysis showed significant correlations for all of the following in the nonreversal group: Ve and all measures of permeability, pulmonary vascular resistance (PVR), and the inverse of permeability-surface area measures and AaDO2 and PVR. Only measures of Ve and PS correlated in the reversal group. These results support the hypothesis that capillary permeability is increased in patients with early ARDS and continuing respiratory failure.« less

  9. Rhenium-osmium isotope systematics of ordinary chondrites and iron meteorites

    NASA Technical Reports Server (NTRS)

    Walker, R. J.; Morgan, J. W.; Horan, M. F.; Grossman, J. N.

    1993-01-01

    Using negative thermal ionization mass spectrometry, Re and Os abundances were determined by isotope dilution and Os-187/Os-186 measured in 11 ordinary chondrites, and also in 1 IIB and 3 IIIB irons. In addition, Os-186/Os-188 and Os-189/Os-188 ratios were precisely determined for 3 unspiked ordinary chondrites as a means of constraining the intensity of any neutron irradiation these meteorites may have experienced.

  10. Osmium, tungsten, and chromium isotopes in sediments and in Ni-rich spinel at the K-T boundary: Signature of a chondritic impactor

    NASA Astrophysics Data System (ADS)

    Quitté, Ghylaine; Robin, Eric; Levasseur, Sylvain; Capmas, Françoise; Rocchia, Robert; Birck, Jean-Louis; Allègre, Claude Jean

    It is now established that a large extraterrestrial object hit the Earth at the end of the Cretaceous period, about 65 Ma ago. We have investigated Re-Os, Hf-W, and Mn-Cr isotope systems in sediments from the Cretaceous and the Paleogene in order to characterize the type of impactor. Within the Cretaceous-Tertiary (K-T) boundary layer, extraterrestrial material is mixed with terrestrial material, causing a dilution of the extraterrestrial isotope signature that is difficult to quantify. A phase essentially composed of Ni-rich spinel, formed in the atmosphere mainly from melted projectile material, is likely to contain the extraterrestrial isotopic signature of the impactor. We show that the analysis of spinel is indeed the best approach to determine the initial isotope composition of the impactor, and that W and Cr isotopes confirm that the projectile was a carbonaceous chondrite.

  11. Inoculation of Bacillus sphaericus UPMB-10 to Young Oil Palm and Measurement of Its Uptake of Fixed Nitrogen Using the 15N Isotope Dilution Technique

    PubMed Central

    Zakry, Fitri Abdul Aziz; Shamsuddin, Zulkifli H.; Rahim, Khairuddin Abdul; Zakaria, Zin Zawawi; Rahim, Anuar Abdul

    2012-01-01

    There are increasing applications of diazotrophic rhizobacteria in the sustainable agriculture system. A field experiment on young immature oil palm was conducted to quantify the uptake of N derived from N2 fixation by the diazotroph Bacillus sphaericus strain UPMB-10, using the 15N isotope dilution method. Eight months after 15N application, young immature oil palms that received 67% of standard N fertilizer application together with B. sphaericus inoculation had significantly lower 15N enrichment than uninoculated palms that received similar N fertilizers. The dilution of labeled N served as a marker for the occurrence of biological N2 fixation. The proportion of N uptake that was derived from the atmosphere was estimated as 63% on the whole plant basis. The inoculation process increased the N and dry matter yields of the palm leaflets and rachis significantly. Field planting of young, immature oil palm in soil inoculated with B. sphaericus UPMB-10 might mitigate inorganic fertilizer-N application through supplementation by biological nitrogen fixation. This could be a new and important source of nitrogen biofertilizer in the early phase of oil palm cultivation in the field. PMID:22446306

  12. Hillslope-Riparian-Streamflow Interactions in a Discontinuous Permafrost Alpine Environment

    NASA Astrophysics Data System (ADS)

    Carey, S. K.

    2004-12-01

    Hillslope-riparian-streamflow interactions are poorly characterized in mountainous discontinuous permafrost environments. Permafrost underlain soils have a distinct soil profile, characterized by thick near-surface organic horizons atop ice-rich mineral substrates, whereas slopes without permafrost have thinner or absent organic soils overlying well drained mineral horizons. Riparian areas occur at the base of both seasonally frozen and permafrost slopes, yet a stronger hydrologic and soil transition occurs at slope bases with only seasonal frost. In a subarctic alpine catchment within the Wolf Creek Research Basin, Yukon, Canada, experiments were conducted between 2001 and 2003 to evaluate linkages along the slope-riparian-stream continuum during melt and post-melt periods. Water table, hydraulic head, stable isotope (d2H, d18O) and simple geochemical (pH, SpC, DOC) data were collected along transects during melt and summer periods. In soils with only seasonal frost, there was a downward piezometric gradient in slopes and upward gradient in riparian areas during melt. In contrast, permafrost soils did not show a recharge/discharge gradient between the slope and riparian zone. DOC declined and SpC increased with depth at all sites during melt. DOC was lower in riparian zones and areas without organic soils. SpC declined in soils as dilute meltwater entered the soil, yet it was difficult to establish spatial relations due to differences in melt timing. The similarity in stable isotope composition among sites indicated that the slopes were well flushed with snowmelt water to depth. DOC in streamflow was greatest on the ascending freshet hydrograph, and declined rapidly following melt. Streamflow SpC declined dramatically in response to dilute meltwater inputs and a decline in stream pH indicates flowpaths through organic horizons. Following melt, DOC concentrations declined rapidly in both slopes and riparian areas. In summer, water tables lowered in seasonally frozen slopes, yet an upward hydraulic gradient and near-surface water table was maintained in the riparian area. In permafrost slopes, water tables fell into mineral soils, increasing SpC and reducing DOC. Riparian water tables remained high and DOC was greater than the seasonally frozen soils, yet riparian zone hydraulic gradient reversed suggesting a small recharge gradient. In permafrost soil, riparian zone DOC was an order of magnitude higher than seasonally frozen riparian zones, which had DOC concentrations similar to streamflow. The similarity in stable isotope ratios among sites throughout the summer indicated that soil waters were dominated by water supplied during melt period. Rainfall waters had little long-term effect on slope and riparian isotopic ratios. Mixing analysis of geochemical and isotopic parameters indicates that during melt, most water was supplied via near surface organic layers, whereas later in the year, subsurface pathways predominated. Permafrost slope-riparian zones have a different hydraulic and geochemical interaction than seasonally frozen ones, yet their respective contribution to streamflow during different times of the year remains unclear at this time.

  13. [Uncertainty evaluation of the determination of toxic equivalent quantity of polychlorinated dibenzo-p-dioxins and dibenzofurans in soil by isotope dilution high resolution gas chromatography and high resolution mass spectrometry].

    PubMed

    Du, Bing; Liu Aimin; Huang, Yeru

    2014-09-01

    Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in soil samples were analyzed by isotope dilution method with high resolution gas chromatography and high resolution mass spectrometry (ID-HRGC/HRMS), and the toxic equivalent quantity (TEQ) were calculated. The impacts of major source of measurement uncertainty are discussed, and the combined relative standard uncertainties were calculated for each 2, 3, 7, 8 substituted con- gener. Furthermore, the concentration, combined uncertainty and expanded uncertainty for TEQ of PCDD/Fs in a soil sample in I-TEF, WHO-1998-TEF and WHO-2005-TEF schemes are provided as an example. I-TEF, WHO-1998-TEF and WHO-2005-TEF are the evaluation schemes of toxic equivalent factor (TEF), and are all currently used to describe 2,3,7,8 sub- stituted relative potencies.

  14. Determination of gamma-aminobutyric acid in food matrices by isotope dilution hydrophilic interaction chromatography coupled to mass spectrometry.

    PubMed

    Zazzeroni, Raniero; Homan, Andrew; Thain, Emma

    2009-08-01

    The estimation of the dietary intake of gamma-aminobutyric acid (GABA) is dependent upon the knowledge of its concentration values in food matrices. To this end, an isotope dilution liquid chromatography-mass spectrometry method has been developed employing the hydrophilic interaction chromatography technique for analyte separation. This approach enabled accurate quantification of GABA in apple, potato, soybeans, and orange juice without the need of a pre- or post-column derivatization reaction. A selective and precise analytical measurement has been obtained with a triple quadrupole mass spectrometer operating in multiple reaction monitoring using the method of standard additions and GABA-d(6) as an internal standard. The concentrations of GABA found in the matrices tested are 7 microg/g of apple, 342 microg/g of potatoes, 211 microg/g of soybeans, and 344 microg/mL of orange juice.

  15. Quantitation of (R)- and (S)-linalool in beer using solid phase microextraction (SPME) in combination with a stable isotope dilution assay (SIDA).

    PubMed

    Steinhaus, Martin; Fritsch, Helge T; Schieberle, Peter

    2003-11-19

    A stable isotope dilution assay (SIDA) was developed for the quantitation of both linalool enantiomers using synthesized [2H(2)]R/S-linalool as the internal standard. For enrichment of the target compound from beer, a solid phase microextraction method (SPME) was developed. In comparison to the more time-consuming extraction/distillation cleanup of the beer samples, the results obtained by SPME/SIDA were very similar, even under nonequilibration conditions. Analysis of five different types of beer showed significant differences in the linalool concentrations, which were clearly correlated with the intensity of the hoppy aroma note as evaluated by a sensory panel. In addition, significant differences in the R/S ratios were measured in the beers. The SPME/SIDA yielded exact data independently from headspace sampling parameters, such as exposure time or ionic strength of the solution.

  16. Improvements in Cd stable isotope analysis achieved through use of liquid–liquid extraction to remove organic residues from Cd separates obtained by extraction chromatography† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c5ja00115c Click here for additional data file.

    PubMed Central

    Rehkämper, Mark; Kreissig, Katharina; Coles, Barry; van de Flierdt, Tina

    2016-01-01

    Organic compounds released from resins that are commonly employed for trace element separations are known to have a detrimental impact on the quality of isotopic analyses by MC-ICP-MS. A recent study highlighted that such effects can be particularly problematic for Cd stable isotope measurements (M. Gault-Ringold and C. H. Stirling, J. Anal. At. Spectrom., 2012, 27, 449–459). In this case, the final stage of sample purification commonly applies extraction chromatography with Eichrom TRU resin, which employs particles coated with octylphenyl-N,N-di-isobutyl carbamoylphosphine oxide (CMPO) dissolved in tri-n-butyl phosphate (TBP). During chromatography, it appears that some of these compounds are eluted alongside Cd and cannot be removed by evaporation due to their high boiling points. When aliquots of the zero-ε reference material were processed through the purification procedure, refluxed in concentrated HNO3 and analyzed at minimum dilution (in 1 ml 0.1 M HNO3), they yielded Cd isotopic compositions (ε114/110Cd = 4.6 ± 3.4, 2SD, n = 4) that differed significantly from the expected value, despite the use of a double spike technique to correct for instrumental mass fractionation. This result was accompanied by a 35% reduction in instrumental sensitivity for Cd. With increasing dilution of the organic resin residue, both of these effects are reduced and they are insignificant when the eluted Cd is dissolved in ≥3 ml 0.1 M HNO3. Our results, furthermore, indicate that the isotopic artefacts are most likely related to anomalous mass bias behavior. Previous studies have shown that perchloric acid can be effective at avoiding such effects (Gault-Ringold and Stirling, 2012; K. C. Crocket, M. Lambelet, T. van de Flierdt, M. Rehkämper and L. F. Robinson, Chem. Geol., 2014, 374–375, 128–140), presumably by oxidizing the resin-derived organics, but there are numerous disadvantages to its use. Here we show that liquid–liquid extraction with n-heptane removes the organic compounds, dramatically improving quality of the Cd isotope data for samples that are analyzed at or close to minimum dilution factors. This technique is quick, simple and may be of use prior to analysis of other isotope systems where similar resins are employed. PMID:27284213

  17. Fast methodology for the reliable determination of nonylphenol in water samples by minimal labeling isotope dilution mass spectrometry.

    PubMed

    Fabregat-Cabello, Neus; Castillo, Ángel; Sancho, Juan V; González, Florenci V; Roig-Navarro, Antoni Francesc

    2013-08-02

    In this work we have developed and validated an accurate and fast methodology for the determination of 4-nonylphenol (technical mixture) in complex matrix water samples by UHPLC-ESI-MS/MS. The procedure is based on isotope dilution mass spectrometry (IDMS) in combination with isotope pattern deconvolution (IPD), which provides the concentration of the analyte directly from the spiked sample without requiring any methodological calibration graph. To avoid any possible isotopic effect during the analytical procedure the in-house synthesized (13)C1-4-(3,6-dimethyl-3-heptyl)phenol was used as labeled compound. This proposed surrogate was able to compensate the matrix effect even from wastewater samples. A SPE pre-concentration step together with exhaustive efforts to avoid contamination were included to reach the signal-to-noise ratio necessary to detect the endogenous concentrations present in environmental samples. Calculations were performed acquiring only three transitions, achieving limits of detection lower than 100ng/g for all water matrix assayed. Recoveries within 83-108% and coefficients of variation ranging from 1.5% to 9% were obtained. On the contrary a considerable overestimation was obtained with the most usual classical calibration procedure using 4-n-nonylphenol as internal standard, demonstrating the suitability of the minimal labeling approach. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Stable Isotopic Constraints on Abiogenic Hydrocarbon gas Contributions to Thermogenic Natural gas Resources in the Northern Appalachian Basin, USA

    NASA Astrophysics Data System (ADS)

    Burruss, R. C.; Laughrey, C. D.

    2006-05-01

    The generation of abiogenic methane by serpentinization or by graphite-water reactions in high-grade metamorphic rocks is well documented by isotopic, fluid inclusion, and petrographic studies. However, geochemical evidence is equivocal for abiogenic generation of higher hydrocarbon gases (ethane through pentane) in economic resources. Thermogenic hydrocarbon gases, generated by thermal cracking of sedimentary organic matter of biological origin, are progressively enriched in 13C as a function of increasing number of carbon atoms in the molecule. The isotopic composition is controlled by the kinetic isotope effect (KIE) during carbon-carbon bond breaking with the largest KIE for methane. Published work on gases in Precambrian rocks in Canada and South Africa suggest that some were generated by abiogenic Fischer-Tropsch type reactions that produced gases with carbon isotopic compositions that are reversed from the thermogenic trend. We have documented reversed isotopic compositions in natural gas accumulations in lower Paleozoic reservoirs of the Appalachian basin regionally from West Virginia and eastern Ohio through Pennsylvania to central New York. The regional accumulation in lower Silurian age strata shows progressive enhancement of the isotopic reversal with increasing depth in the basin. Multivariate analysis of the molecular and isotopic data define an end-member in the deep basin with an approximate composition of 98 mol % CH4, 1-2 mol % C2H6, << 1 mol % C3H8, and δ13C (CH4) = -27 ‰, δ13C (C2H6) = -40 ‰, δ13C (C3H8) = - 41‰. The nominal similarity of isotopic reversals in the gases from Precambrian rocks to those in the lower Paleozoic rocks of the Appalachian basin suggests that abiogenic F-T reactions may have generated some fraction of the gases in the deep basin. Comparison of molecular and hydrogen isotopic compositions show that the gases of putative abiogenic F-T origin are significantly different from Appalachian basin gases. All the Precambrian gases have extremely light hydrogen isotopic compositions of CH4 (δ2H < -300‰) and are depleted in CH4 (Canada gases C1/C2+ < 10, S. Africa gases C1/C2+ < 60) compared to gases in lower Paleozoic reservoirs of the Appalachian basin (δ2H (CH4) > -150‰, C1/C2+ up to 220). New isotopic studies of gas accumulations, gases in fluid inclusions, and of sedimentary organic matter in the Appalachian basin are in progress to constrain the possible contribution of abiogenic hydrocarbon generation to gas accumulations in this basin.

  19. Development of a candidate reference measurement procedure for the analysis of cortisol in human serum samples by isotope dilution-gas chromatography-mass spectrometry.

    PubMed

    Kawaguchi, Migaku; Takatsu, Akiko

    2009-08-01

    A candidate reference measurement procedure involving isotope dilution coupled with gas chromatography-mass spectrometry (GC-MS) has been developed and critically evaluated. An isotopically labeled internal standard, cortisol-d(2), was added to a serum sample. After equilibration, solid-phase extractions (SPE) for sample preparation and derivatization with heptafluorobutyric anhydride (HFBA) were performed for GC-MS analysis. The limit of detection (LOD) and the limit of quantification (LOQ) were 5 and 20 ng g(-1), respectively. The recovery of the added cortisol ranged from 99.8 to 101.0%. Excellent precision was obtained with a within-day variation (RSD) of 0.7% for GC-MS analysis. The accuracy of the measurement was evaluated by comparing of results of this reference measurement procedure on lyophilized human serum reference materials for cortisol (European Reference Materials (ERM)-DA 192) as Certified Reference Materials (CRMs). The results of this method for total cortisol agreed with the certified values within some uncertainty. This method, which demonstrates simply, easy, good accuracy, high precision, and is free from interferences from structural analogues, qualifies as a reference measurement procedure.

  20. Stable isotope dilution HILIC-MS/MS method for accurate quantification of glutamic acid, glutamine, pyroglutamic acid, GABA and theanine in mouse brain tissues.

    PubMed

    Inoue, Koichi; Miyazaki, Yasuto; Unno, Keiko; Min, Jun Zhe; Todoroki, Kenichiro; Toyo'oka, Toshimasa

    2016-01-01

    In this study, we developed the stable isotope dilution hydrophilic interaction liquid chromatography with tandem mass spectrometry (HILIC-MS/MS) technique for the accurate, reasonable and simultaneous quantification of glutamic acid (Glu), glutamine (Gln), pyroglutamic acid (pGlu), γ-aminobutyric acid (GABA) and theanine in mouse brain tissues. The quantification of these analytes was accomplished using stable isotope internal standards and the HILIC separating mode to fully correct the intramolecular cyclization during the electrospray ionization. It was shown that linear calibrations were available with high coefficients of correlation (r(2)  > 0.999, range from 10 pmol/mL to 50 mol/mL). For application of the theanine intake, the determination of Glu, Gln, pGlu, GABA and theanine in the hippocampus and central cortex tissues was performed based on our developed method. In the region of the hippocampus, the concentration levels of Glu and pGlu were significantly reduced during reality-based theanine intake. Conversely, the concentration level of GABA increased. This result showed that transited theanine has an effect on the metabolic balance of Glu analogs in the hippocampus. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Evaluation of Adsorbed Arsenic and Potential Contribution to Shallow Groundwater in Tulare Lake Bed Area, Tulare Basin, California

    USGS Publications Warehouse

    Gao, S.; Fujii, R.; Chalmers, A.T.; Tanji, K.K.

    2004-01-01

    Elevated As concentrations in shallow groundwater in parts of the Tulare Basin, California, are a concern because of potential migration into deeper aquifers that could serve as a source of future drinking water. The objectives of this study were to evaluate adsorbed As and the potential contribution to groundwater using (i) isotopic dilution, (ii) successive extraction with an electrolyte solution resembling the pore-water chemical composition, and (iii) PO4 exchange for As. Sediment samples collected from 2 to 4 m below land surface in the Tulare Lake bed area contained a total As concentration of 24 mg As kg-1. Pore water extracted under hydraulic pressure contained a total As concentration of 590 ??g As L-1, which predominantly contained As as arsenate [As(V), 97%], a minor amount of arsenite [As(III), 3%], and non-detectable organic As. The isotopic dilution method [73As(V)] estimated that the concentration of adsorbed As(V) on the sediment was 5.7 mg As kg-1 at pH 8.5 and 6.7 mg As kg-1 at pH 7.5, respectively. Fourteen successive 24-h extractions with the artificial pore water released up to 57 to 61% of the adsorbed As(V) that was determined by isotopic dilution, indicating that only a portion of the adsorbed As could be released to groundwater. The phosphate-exchangeable As (0.1 M PO4, pH 8.5 or 7.5) was 63% of the isotopically exchangeable As(V). Thus, extraction of As by 0.1 M PO4 at ambient pHs is recommended as a method to determine the potential amount of As(V) on sediments that could be released to the solution phase. The overall results indicated that adsorbed As could be a significant source of As to groundwater. However, other factors that affect As transport such as the leaching rate need to be considered.

  2. Comparisons among Equations Used for Retinol Isotope Dilution in the Assessment of Total Body Stores and Total Liver Reserves.

    PubMed

    Gannon, Bryan M; Tanumihardjo, Sherry A

    2015-05-01

    Vitamin A plays an essential role in animal biology and has negative effects associated with both hypo- and hypervitaminosis A. Many notable interventions are being done globally to eliminate vitamin A deficiency, including supplementation, fortification, and biofortification. At the same time, it is important to monitor vitamin A status in nations where preformed vitamin A intake is high because of consumption of animal source foods (e.g., liver, dairy, eggs), fortified foods (e.g., milk, cereals, oil, sugar, margarine), or vitamin supplements (e.g., one-a-day multivitamins) to ensure the population does not reach hypervitaminosis A. To accurately assess population status and evaluate interventions aimed at improving vitamin A status, accurate assessment methods are needed. The primary storage site of vitamin A is the liver; however, routinely obtaining liver samples from humans is impractical and unethical. Isotope dilution using deuterium- or (13)C-labeled retinol is currently the most sensitive indirect biomarker of vitamin A status across a wide range of liver reserves. The major drawback to its application is the increased technicality in sample analysis and data calculations when compared to less sensitive methodology, such as serum retinol concentrations and dose response tests. Two main equations have emerged for calculating vitamin A body pool size or liver concentrations from isotope dilution data: the "Olson equation" and the "mass balance equation." Different applications of these equations can lead to confusion and lack of consistency if the underlying principles and assumptions used are not clarified. The purpose of this focused review is to describe the evolution of the equations used in retinol stable-isotope work and the assumptions appropriate to different applications of the test. Ultimately, the 2 main equations are shown to be fundamentally the same and differ only in assumptions made for each specific research application. © 2015 American Society for Nutrition.

  3. A critical review of inductively coupled plasma-mass spectrometry for geoanalysis, geochemistry and hydrology, Part 1. Analytical performance

    USGS Publications Warehouse

    Brenner, I.B.; Taylor, Howard E.

    1992-01-01

    Present-day inductively coupled plasma-mass spectrometry (ICP-MS) instrumentation is described briefly. Emphasis is placed on performance characteristics for geoanalysis, geochemistry, and hydrology. Applications where ICP-MS would be indispensable are indicated. Determination of geochemically diagnostic trace elements (such as the rare earth elements [REE], U and Th), of isotope ratios for fingerprinting, tracer and other geo-isotope applications, and benchmark isotope dilution determinations are considered to be typical priority applications for ICP-MS. It is concluded that ICP-MS furnishes unique geoanalytical and environmental data that are not readily provided by conventional spectroscopic (emission and absorption) techniques.

  4. Isotope pattern deconvolution as rising tool for isotope tracer studies in environmental research

    NASA Astrophysics Data System (ADS)

    Irrgeher, Johanna; Zitek, Andreas; Prohaska, Thomas

    2014-05-01

    During the last decade stable isotope tracers have emerged as versatile tool in ecological research. Besides 'intrinsic' isotope tracers caused by the natural variation of isotopes, the intentional introduction of 'extrinsic' enriched stable isotope tracers into biological systems has gained significant interest. Hereby the induced change in the natural isotopic composition of an element allows amongst others for studying the fate and fluxes of metals, trace elements and species in organisms or provides an intrinsic marker or tag of particular biological samples. Due to the shoreless potential of this methodology, the number of publications dealing with applications of isotope (double) spikes as tracers to address research questions in 'real world systems' is constantly increasing. However, some isotope systems like the natural Sr isotopic system, although potentially very powerful for this type of application, are still rarely used, mainly because their adequate measurement/determination poses major analytical challenges; as e.g. Sr is available in significant amounts in natural samples. In addition, biological systems underlie complex processes such as metabolism, adsorption/desorption or oxidation/reduction. As a consequence, classic evaluation approaches such as the isotope dilution mass spectrometry equation are often not applicable because of the unknown amount of tracer finally present in the sample. Isotope pattern deconvolution (IPD), based on multiple linear regression, serves as simplified alternative data processing strategy to double spike isotope dilution calculations. The outstanding advantage of this mathematical tool lies in the possibility of deconvolving the isotope pattern in a spiked sample without knowing the quantities of enriched isotope tracer being incorporated into the natural sample matrix as well as the degree of impurities and species-interconversion (e.g. from sample preparation). Here, the potential of IPD for environmental tracer studies is critically discussed, where special emphasis is set on evaluating different data processing strategies on the example of enriched stable Sr isotopes.1 The analytical key parameters such as blank (Kr, Sr and Rb), variation of the natural Sr isotopic composition in the sample, mass bias, interferences (Rb) and total combined uncertainty are considered. A full metrological protocol for data processing using IPD is presented based on data gained during two transgenerational marking studies of fish, where the transfer of a Sr isotope double spike (84Sr and 86Sr) from female spawners of common carp (Cyprinus carpio L.) and brown trout (Salmo trutta f.f.)2 to the centre of the otoliths of their offspring was studied by (LA)-MC-ICP-MS. 1J. Irrgeher, A. Zitek, M. Cervicek and T. Prohaska, J. Anal. At. Spectrom., 2014, 29, 193-200. 2A. Zitek, J. Irrgeher, M. Kletzl, T. Weismann and T. Prohaska, Fish. Manage. Ecol., 2013, 20, 654-361.

  5. Translating Thermal Response of Triblock Copolymer Assemblies in Dilute Solution to Macroscopic Gelation and Phase Separation

    DOE PAGES

    Sun, Zhe; Tian, Ye; Hom, Wendy L.; ...

    2016-12-28

    The thermal response of semi-dilute solutions (5 w/w%) of two amphiphilic thermoresponsive poly(ethylene oxide)-b-poly(N,N-diethylacrylamide)-b-poly(N,N-dibutylacrylamide) (PEO 45-PDEAm x-PDBAm 12) triblock copolymers, which differ only in the size of the central responsive block, in water was examined in this paper. Aqueous PEO45-PDEAm41-PDBAm12 solutions, which undergo a thermally induced sphere-to-worm transition in dilute solution, were found to reversibly form soft (G'≈10 Pa) free-standing physical gels after 10 min at 55 °C. PEO 45-PDEAm 89-PDBAm 12 copolymer solutions, which undergo a thermally induced transition from spheres to large compound micelles (LCM) in dilute solution, underwent phase separation after heating at 55 °C for 10more » min owing to sedimentation of LCMs. The reversibility of LCM formation was investigated as a non-specific method for removal of a water-soluble dye from aqueous solution. Finally, the composition and size of the central responsive block in these polymers dictate the microscopic and macroscopic response of the polymer solutions as well as the rates of transition between assemblies.« less

  6. Simple, rapid method for the preparation of isotopically labeled formaldehyde

    DOEpatents

    Hooker, Jacob Matthew [Port Jefferson, NY; Schonberger, Matthias [Mains, DE; Schieferstein, Hanno [Aabergen, DE; Fowler, Joanna S [Bellport, NY

    2011-10-04

    Isotopically labeled formaldehyde (*C.sup..sctn.H.sub.2O) is prepared from labeled methyl iodide (*C.sup..sctn.H.sub.3I) by reaction with an oxygen nucleophile having a pendant leaving group. The mild and efficient reaction conditions result in good yields of *C.sup..sctn.H.sub.2O with little or no *C isotopic dilution. The simple, efficient production of .sup.11CH.sub.2O is described. The use of the .sup.11CH.sub.2O for the formation of positron emission tomography tracer compounds is described. The reaction can be incorporated into automated equipment available to radiochemistry laboratories. The isotopically labeled formaldehyde can be used in a variety of reactions to provide radiotracer compounds for imaging studies as well as for scintillation counting and autoradiography.

  7. Simultaneous quantification of 21 water soluble vitamin circulating forms in human plasma by liquid chromatography-mass spectrometry.

    PubMed

    Meisser Redeuil, Karine; Longet, Karin; Bénet, Sylvie; Munari, Caroline; Campos-Giménez, Esther

    2015-11-27

    This manuscript reports a validated analytical approach for the quantification of 21 water soluble vitamins and their main circulating forms in human plasma. Isotope dilution-based sample preparation consisted of protein precipitation using acidic methanol enriched with stable isotope labelled internal standards. Separation was achieved by reversed-phase liquid chromatography and detection performed by tandem mass spectrometry in positive electrospray ionization mode. Instrumental lower limits of detection and quantification reached <0.1-10nM and 0.2-25nM, respectively. Commercially available pooled human plasma was used to build matrix-matched calibration curves ranging 2-500, 5-1250, 20-5000 or 150-37500nM depending on the analyte. The overall performance of the method was considered adequate, with 2.8-20.9% and 5.2-20.0% intra and inter-day precision, respectively and averaged accuracy reaching 91-108%. Recovery experiments were also performed and reached in average 82%. This analytical approach was then applied for the quantification of circulating water soluble vitamins in human plasma single donor samples. The present report provides a sensitive and reliable approach for the quantification of water soluble vitamins and main circulating forms in human plasma. In the future, the application of this analytical approach will give more confidence to provide a comprehensive assessment of water soluble vitamins nutritional status and bioavailability studies in humans. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. RADIOISOTOPES USED IN PHARMACY. 5. IONIZING RADIATION IN PHARMACEUTICAL ANALYSIS (in Danish)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kristensen, K.

    1962-09-01

    The use of radioisotope methods for analyzing drugs is reviewed. It is pointed out that heretofore most methods have been based on isotope dilution principles whereas in the future radioactivation analysis, especially with neutron sources, offers great possibilities. (BBB)

  9. Optimization and application of ICPMS with dynamic reaction cell for precise determination of 44Ca/40Ca isotope ratios.

    PubMed

    Boulyga, Sergei F; Klötzli, Urs; Stingeder, Gerhard; Prohaska, Thomas

    2007-10-15

    An inductively coupled plasma mass spectrometer with dynamic reaction cell (ICP-DRC-MS) was optimized for determining (44)Ca/(40)Ca isotope ratios in aqueous solutions with respect to (i) repeatability, (ii) robustness, and (iii) stability. Ammonia as reaction gas allowed both the removal of (40)Ar+ interference on (40)Ca+ and collisional damping of ion density fluctuations of an ion beam extracted from an ICP. The effect of laboratory conditions as well as ICP-DRC-MS parameters such a nebulizer gas flow rate, rf power, lens potential, dwell time, or DRC parameters on precision and mass bias was studied. Precision (calculated using the "unbiased" or "n - 1" method) of a single isotope ratio measurement of a 60 ng g(-1) calcium solution (analysis time of 6 min) is routinely achievable in the range of 0.03-0.05%, which corresponded to the standard error of the mean value (n = 6) of 0.012-0.020%. These experimentally observed RSDs were close to theoretical precision values given by counting statistics. Accuracy of measured isotope ratios was assessed by comparative measurements of the same samples by ICP-DRC-MS and thermal ionization mass spectrometry (TIMS) by using isotope dilution with a (43)Ca-(48)Ca double spike. The analysis time in both cases was 1 h per analysis (10 blocks, each 6 min). The delta(44)Ca values measured by TIMS and ICP-DRC-MS with double-spike calibration in two samples (Ca ICP standard solution and digested NIST 1486 bone meal) coincided within the obtained precision. Although the applied isotope dilution with (43)Ca-(48)Ca double-spike compensates for time-dependent deviations of mass bias and allows achieving accurate results, this approach makes it necessary to measure an additional isotope pair, reducing the overall analysis time per isotope or increasing the total analysis time. Further development of external calibration by using a bracketing method would allow a wider use of ICP-DRC-MS for routine calcium isotopic measurements, but it still requires particular software or hardware improvements aimed at reliable control of environmental effects, which might influence signal stability in ICP-DRC-MS and serve as potential uncertainty sources in isotope ratio measurements.

  10. A practical method for the determination of total selenium in environmental samples using isotope dilution-hydride generation-inductively coupled plasma-mass spectrometry

    USGS Publications Warehouse

    Kleckner, Amy E.; Kakouros, Evangelos; Stewart, A. Robin

    2017-01-01

    A safe, practical, and accurate method for the determination of selenium (Se) in range of environmental samples was developed. Small sample masses, 5–20 mg, were amended with 82Se enriched isotope for the isotope dilution (ID), preceding a multi-step wet digestion with nitric acid (HNO3) and hydrogen peroxide (H2O2). Samples were incubated in an autoclave for 3 h at 20 psi and 126°C. Digestates were subsequently reduced with concentrated hydrochloric acid to Se(IV) the most favorable valence for hydride generation (HG). The solutions were then analyzed on an ICP-MS equipped with Flow Injection system (FIAS-400). Polyatomic, isobaric, and background interferences were removed through the use of HG and ID with an 82Se enriched isotope spike. Recoveries for certified reference materials were determined and averaged 96% for biological tissues (NRCC DOLT3, DOLT4, DORM2, TORT2, and TORT3, and NIST 2976) and 108% for estuarine sediment (NRCC PACS2) with an average coefficient of variation for replicate measurements of ∼ 3.5%. Limit of detection was 0.13 ng Se g−1 dry weight or 0.19 ng Se L−1. This method can be broadly applied to biological tissues, sediments, suspended particulates, and water samples with minimal modifications making this method highly useful for assessing the ecotoxicology of total Se in aquatic ecosystems.

  11. An algorithm for U-Pb isotope dilution data reduction and uncertainty propagation

    NASA Astrophysics Data System (ADS)

    McLean, N. M.; Bowring, J. F.; Bowring, S. A.

    2011-06-01

    High-precision U-Pb geochronology by isotope dilution-thermal ionization mass spectrometry is integral to a variety of Earth science disciplines, but its ultimate resolving power is quantified by the uncertainties of calculated U-Pb dates. As analytical techniques have advanced, formerly small sources of uncertainty are increasingly important, and thus previous simplifications for data reduction and uncertainty propagation are no longer valid. Although notable previous efforts have treated propagation of correlated uncertainties for the U-Pb system, the equations, uncertainties, and correlations have been limited in number and subject to simplification during propagation through intermediary calculations. We derive and present a transparent U-Pb data reduction algorithm that transforms raw isotopic data and measured or assumed laboratory parameters into the isotopic ratios and dates geochronologists interpret without making assumptions about the relative size of sample components. To propagate uncertainties and their correlations, we describe, in detail, a linear algebraic algorithm that incorporates all input uncertainties and correlations without limiting or simplifying covariance terms to propagate them though intermediate calculations. Finally, a weighted mean algorithm is presented that utilizes matrix elements from the uncertainty propagation algorithm to propagate random and systematic uncertainties for data comparison between other U-Pb labs and other geochronometers. The linear uncertainty propagation algorithms are verified with Monte Carlo simulations of several typical analyses. We propose that our algorithms be considered by the community for implementation to improve the collaborative science envisioned by the EARTHTIME initiative.

  12. Development and validation of a liquid chromatography isotope dilution mass spectrometry method for the reliable quantification of alkylphenols in environmental water samples by isotope pattern deconvolution.

    PubMed

    Fabregat-Cabello, Neus; Sancho, Juan V; Vidal, Andreu; González, Florenci V; Roig-Navarro, Antoni Francesc

    2014-02-07

    We present here a new measurement method for the rapid extraction and accurate quantification of technical nonylphenol (NP) and 4-t-octylphenol (OP) in complex matrix water samples by UHPLC-ESI-MS/MS. The extraction of both compounds is achieved in 30min by means of hollow fiber liquid phase microextraction (HF-LPME) using 1-octanol as acceptor phase, which provides an enrichment (preconcentration) factor of 800. On the other hand we have developed a quantification method based on isotope dilution mass spectrometry (IDMS) and singly (13)C1-labeled compounds. To this end the minimal labeled (13)C1-4-(3,6-dimethyl-3-heptyl)-phenol and (13)C1-t-octylphenol isomers were synthesized, which coelute with the natural compounds and allows the compensation of the matrix effect. The quantification was carried out by using isotope pattern deconvolution (IPD), which permits to obtain the concentration of both compounds without the need to build any calibration graph, reducing the total analysis time. The combination of both extraction and determination techniques have allowed to validate for the first time a HF-LPME methodology at the required levels by legislation achieving limits of quantification of 0.1ngmL(-1) and recoveries within 97-109%. Due to the low cost of HF-LPME and total time consumption, this methodology is ready for implementation in routine analytical laboratories. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. An isotope-dilution standard GC/MS/MS method for steroid hormones in water

    USGS Publications Warehouse

    Foreman, William T.; Gray, James L.; ReVello, Rhiannon C.; Lindley, Chris E.; Losche, Scott A.

    2013-01-01

    An isotope-dilution quantification method was developed for 20 natural and synthetic steroid hormones and additional compounds in filtered and unfiltered water. Deuterium- or carbon-13-labeled isotope-dilution standards (IDSs) are added to the water sample, which is passed through an octadecylsilyl solid-phase extraction (SPE) disk. Following extract cleanup using Florisil SPE, method compounds are converted to trimethylsilyl derivatives and analyzed by gas chromatography with tandem mass spectrometry. Validation matrices included reagent water, wastewater-affected surface water, and primary (no biological treatment) and secondary wastewater effluent. Overall method recovery for all analytes in these matrices averaged 100%; with overall relative standard deviation of 28%. Mean recoveries of the 20 individual analytes for spiked reagent-water samples prepared along with field samples analyzed in 2009–2010 ranged from 84–104%, with relative standard deviations of 6–36%. Detection levels estimated using ASTM International’s D6091–07 procedure range from 0.4 to 4 ng/L for 17 analytes. Higher censoring levels of 100 ng/L for bisphenol A and 200 ng/L for cholesterol and 3-beta-coprostanol are used to prevent bias and false positives associated with the presence of these analytes in blanks. Absolute method recoveries of the IDSs provide sample-specific performance information and guide data reporting. Careful selection of labeled compounds for use as IDSs is important because both inexact IDS-analyte matches and deuterium label loss affect an IDS’s ability to emulate analyte performance. Six IDS compounds initially tested and applied in this method exhibited deuterium loss and are not used in the final method.

  14. On Presolar Stardust Grains from CO Classical Novae

    NASA Astrophysics Data System (ADS)

    Iliadis, Christian; Downen, Lori N.; José, Jordi; Nittler, Larry R.; Starrfield, Sumner

    2018-03-01

    About 30%–40% of classical novae produce dust 20–100 days after the outburst, but no presolar stardust grains from classical novae have been unambiguously identified yet. Although several studies claimed a nova paternity for certain grains, the measured and simulated isotopic ratios could only be reconciled, assuming that the grains condensed after the nova ejecta mixed with a much larger amount of close-to-solar matter. However, the source and mechanism of this potential post-explosion dilution of the ejecta remains a mystery. A major problem with previous studies is the small number of simulations performed and the implied poor exploration of the large nova parameter space. We report the results of a different strategy, based on a Monte Carlo technique, that involves the random sampling over the most important nova model parameters: the white dwarf composition; the mixing of the outer white dwarf layers with the accreted material before the explosion; the peak temperature and density; the explosion timescales; and the possible dilution of the ejecta after the outburst. We discuss and take into account the systematic uncertainties for both the presolar grain measurements and the simulation results. Only those simulations that are consistent with all measured isotopic ratios of a given grain are accepted for further analysis. We also present the numerical results of the model parameters. We identify 18 presolar grains with measured isotopic signatures consistent with a CO nova origin, without assuming any dilution of the ejecta. Among these, the grains G270_2, M11-334-2, G278, M11-347-4, M11-151-4, and Ag26 have the highest probability of a CO nova paternity.

  15. Evaluation of analytical methodology for the detection of hormones and their attenuation during aquifer recharge and recovery cycles.

    PubMed

    de Lima Stebbins, Daniela; Docs, Jon; Lowe, Paula; Cohen, Jason; Lei, Hongxia

    2016-05-18

    The hormones listed in the screening survey list 2 of the Unregulated Contaminant Monitoring Rule 3 (estrone, 17-β-estradiol, 17-α-ethynylestradiol, 16-α-hydroxyestradiol (estriol), equilin, testosterone and 4-androstene-3,17-dione) were analyzed by liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Two analytical methods were compared: EPA method 539 and the isotope dilution method. EPA method 539 was successfully utilized in river and drinking water matrices with fortified recoveries of 98.9 to 108.5%. Samples from the Hillsborough River reflected levels below the method detection limit (MDL) for the majority of the analytes, except estrone (E1), which was detected at very low concentrations (<0.5 to 1 ng L(-1)) in the majority of samples. No hormones were detected in drinking water samples. The isotope dilution method was used to analyze reclaimed and aquifer storage and recovery (ASR) water samples as a result of strong matrix/solid phase extraction (SPE) losses observed in these more complex matrices. Most of the compounds were not detected or found at relatively low concentrations in the ASR samples. Attenuation of 50 to 99.1% was observed as a result of the ASR recharge/recovery cycles for most of the hormones, except for estriol (E3). Relatively stable concentrations of E3 were found, with only 10% attenuation at one of the sites and no measureable attenuation at another location. These results have substantiated that while EPA method 539 works well for most environmental samples, the isotope dilution method is more robust when dealing with complex matrices such as reclaimed and ASR samples.

  16. Determination of low methylmercury concentrations in peat soil samples by isotope dilution GC-ICP-MS using distillation and solvent extraction methods.

    PubMed

    Pietilä, Heidi; Perämäki, Paavo; Piispanen, Juha; Starr, Mike; Nieminen, Tiina; Kantola, Marjatta; Ukonmaanaho, Liisa

    2015-04-01

    Most often, only total mercury concentrations in soil samples are determined in environmental studies. However, the determination of extremely toxic methylmercury (MeHg) in addition to the total mercury is critical to understand the biogeochemistry of mercury in the environment. In this study, N2-assisted distillation and acidic KBr/CuSO4 solvent extraction methods were applied to isolate MeHg from wet peat soil samples collected from boreal forest catchments. Determination of MeHg was performed using a purge and trap GC-ICP-MS technique with a species-specific isotope dilution quantification. Distillation is known to be more prone to artificial MeHg formation compared to solvent extraction which may result in the erroneous MeHg results, especially with samples containing high amounts of inorganic mercury. However, methylation of inorganic mercury during the distillation step had no effect on the reliability of the final MeHg results when natural peat soil samples were distilled. MeHg concentrations determined in peat soil samples after distillation were compared to those determined after the solvent extraction method. MeHg concentrations in peat soil samples varied from 0.8 to 18 μg kg(-1) (dry weight) and the results obtained with the two different methods did not differ significantly (p=0.05). The distillation method with an isotope dilution GC-ICP-MS was shown to be a reliable method for the determination of low MeHg concentrations in unpolluted soil samples. Furthermore, the distillation method is solvent-free and less time-consuming and labor-intensive when compared to the solvent extraction method. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. A Sequential Leach Method and Pb Isotope Approach to Studying Apatite Weathering in Granitoid Soils at Hubbard Brook Experimental Forest, NH, USA

    NASA Astrophysics Data System (ADS)

    Nezat, C. A.; Blum, J. D.

    2005-12-01

    Easily dissolved minerals such as calcite and apatite can be important in controlling stream and ground water chemistry even though these minerals are only present in trace amounts in granitoid rocks. Because of its solubility, apatite, a calcium phosphate mineral, may be a significant source of essential nutrients (especially phosphorous) for vegetation, and has been shown to strongly influence stream and soil water composition (e.g, calcium, strontium and rare earth elements). There are additional sources of Ca (e.g., feldspars, hornblende) and P (e.g., organic matter or bound to Fe and Al oxides) in granitoid soils. In order to distinguish the chemical constituents of apatite from other pools in the bulk soil, we selectively dissolved apatite with a dilute acid leach, and measured Pb isotopic ratios of apatite, feldspar, and leachates. We tested the leaching procedure on mineral separates and verified that a dilute nitric solution primarily dissolves apatite. Silicates were dissolved in subsequent steps by successively stronger acids. We then applied this method to bulk soils collected from several soil pits across a small watershed at the Hubbard Brook Experimental Forest (HBEF), New Hampshire, USA, to determine the spatial distribution of Ca and P pools, and determine the depth of apatite depletion in the soil. We also measured Pb isotope ratios in the soil leachates to distinguish among the various sources of Pb (e.g., apatite, feldspars and anthropogenic sources). We found that Pb in the dilute nitric leach of the HBEF organic soils is dominated by anthropogenic sources and that Pb from apatite becomes increasingly important with depth.

  18. Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion.

    PubMed

    Heilmann, Jens; Boulyga, Sergei F; Heumann, Klaus G

    2004-09-01

    Inductively coupled plasma isotope-dilution mass spectrometry (ICP-IDMS) with direct injection of isotope-diluted samples into the plasma, using a direct injection high-efficiency nebulizer (DIHEN), was applied for accurate sulfur determinations in sulfur-free premium gasoline, gas oil, diesel fuel, and heating oil. For direct injection a micro-emulsion consisting of the corresponding organic sample and an aqueous 34S-enriched spike solution with additions of tetrahydronaphthalene and Triton X-100, was prepared. The ICP-MS parameters were optimized with respect to high sulfur ion intensities, low mass-bias values, and high precision of 32S/34S ratio measurements. For validation of the DIHEN-ICP-IDMS method two certified gas oil reference materials (BCR 107 and BCR 672) were analyzed. For comparison a wet-chemical ICP-IDMS method was applied with microwave-assisted digestion using decomposition of samples in a closed quartz vessel inserted into a normal microwave system. The results from both ICP-IDMS methods agree well with the certified values of the reference materials and also with each other for analyses of other samples. However, the standard deviation of DIHEN-ICP-IDMS was about a factor of two higher (5-6% RSD at concentration levels above 100 mircog g(-1)) compared with those of wet-chemical ICP-IDMS, mainly due to inhomogeneities of the micro-emulsion, which causes additional plasma instabilities. Detection limits of 4 and 18 microg g(-1) were obtained for ICP-IDMS in connection with microwave-assisted digestion and DIHEN-ICP-IDMS, respectively, with a sulfur background of the used Milli-Q water as the main limiting factor for both methods.

  19. Assessment of Stable Isotope Distribution in Complex Systems

    NASA Astrophysics Data System (ADS)

    He, Y.; Cao, X.; Wang, J.; Bao, H.

    2017-12-01

    Biomolecules in living organisms have the potential to approach chemical steady state and even apparent isotope equilibrium because enzymatic reactions are intrinsically reversible. If an apparent local equilibrium can be identified, enzymatic reversibility and its controlling factors may be quantified, which helps to understand complex biochemical processes. Earlier research on isotope fractionation tends to focus on specific process and compare mostly two different chemical species. Using linear regression, "Thermodynamic order", which refers to correlated δ13C and 13β values, has been proposed to be present among many biomolecules by Galimov et al. However, the concept "thermodynamic order" they proposed and the approach they used has been questioned. Here, we propose that the deviation of a complex system from its equilibrium state can be rigorously described as a graph problem as is applied in discrete mathematics. The deviation of isotope distribution from equilibrium state and apparent local isotope equilibrium among a subset of biomolecules can be assessed using an apparent fractionation difference matrix (|Δα|). Applying the |Δα| matrix analysis to earlier published data of amino acids, we show the existence of apparent local equilibrium among different amino acids in potato and a kind of green alga. The existence of apparent local equilibrium is in turn consistent with the notion that enzymatic reactions can be reversible even in living systems. The result also implies that previous emphasis on external carbon source intake may be misplaced when studying isotope distribution in physiology. In addition to the identification of local equilibrium among biomolecules, the difference matrix approach has the potential to explore chemical or isotope equilibrium state in extraterrestrial bodies, to distinguish living from non-living systems, and to classify living species. This approach will benefit from large numbers of systematic data and advanced pattern recognition techniques.

  20. New Hf isotope data from the Jack Hills zircons: constraints on the Hadean crustal evolution

    NASA Astrophysics Data System (ADS)

    Amelin, Y.; Davis, D.; Lee, D.

    2004-05-01

    Here we present a follow-up of our study of the "older" population of detrital zircons from the Jack Hills metaconglomerate W-74 [1]. We report Lu-Hf data for zircon grains, which have been previously analyzed with a number of techniques: BSE and CL imaging, detailed U-Pb SHRIMP geochronology, trace element concentrations, and oxygen isotopic compositions. After completion of non-destructive SIMS analyses and imaging, the zircons were extracted from the mounts, dissolved and analyzed for U-Pb and Lu-Hf using isotope dilution. Twenty five grains were air abraded before digestion, and eight grains were digested without abrasion. Four grains were cut, and the fragments were analyzed for U-Pb and Lu-Hf separately. The 207Pb/206Pb ages determined by isotope dilution vary between 3788-4186 Ma; the maximum SHRIMP spot 207Pb/206Pb ages of the same grains are between 3871-4276 Ma. The spot 207Pb/206Pb ages averaged over each grain are close to the whole grain isotope dilution values. The U-Pb discordance depends mainly on whether the grains were abraded: the median discordance of 27 abraded grains and fragments is 2.7 (the range is -0.4 to 20.2), whereas the median discordance of 11 unabraded grains and fragments is 66.5 (the range is 20.5 to 83.5). The epsilon176Hf values, calculated using the whole grain TIMS 207Pb/206Pb ages and the 176Lu decay constant of 1.865*10-11, are between -1.4 and -10.6. Using maximum SHRIMP spot 207Pb/206Pb ages and the same decay constant yields the range of epsilon176Hf of 0.1 to -8.6. If the decay constant of 1.983*10-11 is used instead, then the range of epsilon176Hf becomes 4.7 to -5.0 using the whole grain ages, or 6.3 to -3.0 using the maximum SHRIMP spot ages. Grain fragment analyses show internal variations of initial 176Hf/177Hf in three grains out of five. This observation is consistent with multi-episodic zircon growth rather than with ancient Pb loss. In the presentation we shall discuss the prospect of reliable interpretation of the Hf isotope from the Jack Hills detrital zircons and from other complex ancient zircon populations. [1] Amelin et al. 2001, Proceedings of the Archean-2001 symposium, Perth, WA.

  1. Headspace solid phase microextraction--GC/C-IRMS for delta13CVPDB measurements of mono-aromatic hydrocarbons using EA-IRMS calibration.

    PubMed

    Ebongué, Véronique Woule; Geypens, Benny; Berglund, Michael; Taylor, Philip

    2009-03-01

    This work aims at comparing the delta(13)C(VPDB) of mono-aromatic hydrocarbons benzene, toluene, ethylbenzene and xylene isomers (BTEX) measured by elemental analyser (EA)-isotope ratio mass spectrometer (IRMS) with the delta(13)C(VPDB) measured on the same compounds by headspace solid phase microextraction - GC/C-IRMS (hSPME - GC/C-IRMS) with the final goal of using these compounds as internal standards on the latter system. The EA-IRMS measurements were done using calcium and lithium carbonate isotopic reference materials: NBS19 and L-SVEC for establishing the delta(13)C(VPDB) scale. The EA-IRMS measurements with helium dilution of a set of five reference materials (USGS40, USGS41, IAEA-CH-6, IAEA-CH-3 and IAEA-601) show systematic bias of 1 per thousand relative to their assigned values. This bias due to the dilution mechanism in the used ConfloII interface device could not be avoided. As the selected hydrocarbons: BTEX could not be analysed by EA-IRMS without helium dilution, their delta(13)C(VPDB) must be corrected from this observed bias using an external calibration. The CO(2) gas calibrated using EA-IRMS without helium dilution, was used as an in-house reference for the delta(13)C(VPDB) measurements of the BTEX by the hSPME - GC/C-IRMS system. The comparison made between the delta(13)C(VPDB) measured on the same BTEX compounds by EA-IRMS (with external calibration) and by hSPME - GC/C-IRMS techniques showed good agreement.

  2. Ultrasonication extraction and gel permeation chromatography clean-up for the determination of polycyclic aromatic hydrocarbons in edible oil by an isotope dilution gas chromatography–mass spectrometry.

    PubMed

    Wang, Jian-Hua; Guo, Cui

    2010-07-09

    An analytical method for the determination of US EPA priority pollutant 16 polycyclic aromatic hydrocarbons (PAHs) in edible oil was developed by an isotope dilution gas chromatography-mass spectrometry (GC-MS). Extraction was performed with ultrasonication mode using acetonitrile as solvent, and subsequent clean-up was applied using narrow gel permeation chromatographic column. Three deuterated PAHs surrogate standards were used as internal standards for quantification and analytical quality control. The limits of quantification (LOQs) were globally below 0.5 ng/g, the recoveries were in the range of 81-96%, and the relative standard deviations (RSDs) were lower than 20%. Further trueness assessment of the method was also verified through participation in international cocoa butter proficiency test (T0638) organised by the FAPAS with excellent results in 2008. The results obtained with the described method were satisfying (z ≤ 2). The method has been applied to determine PAH in real edible oil samples.

  3. A comparative study on the skin penetration of pure tryptanthrin and tryptanthrin in Isatis tinctoria extract by dermal microdialysis coupled with isotope dilution ESI-LC-MS.

    PubMed

    Oberthür, Christine; Heinemann, Christian; Elsner, Peter; Benfeldt, Eva; Hamburger, Matthias

    2003-05-01

    The indolo[2,1- b]quinazoline alkaloid tryptanthrin has recently been identified as a pharmacologically active compound in Isatis tinctoria, with potent dual inhibitory activity on prostaglandin and leukotriene synthesis. To investigate the skin penetration of tryptanthrin from solutions of pure compound and Isatis extracts, we developed and validated a cutaneous microdialysis model using ex vivo pig foreleg. Microdialysis was performed by placing linear probes in the dermis of the skin in situ, and tryptanthrin concentrations in the dialysates were determined by isotope dilution electrospray ionization LC-MS in the selected ion mode. Measurable concentrations of tryptanthrin were detected 30 min after application. A dose-dependent increase in tryptanthrin concentrations in the dialysate was observed for the Isatis extracts, but not for pure tryptanthrin. Microscopic analysis showed that the pure compound crystallized from the solution but remained in an amorphous state in the extracts.

  4. Quantification of four artificial sweeteners in Finnish surface waters with isotope-dilution mass spectrometry.

    PubMed

    Perkola, Noora; Sainio, Pirjo

    2014-01-01

    The artificial sweeteners sucralose (SCL), acesulfame (ACS), saccharin (SAC), and cyclamate (CYC) have been detected in environmental waters in Europe and North America. Higher environmental levels are expected in view of the increasing consumption of these food additives. In this study, an isotope-dilution mass spectrometry (IDMS) LC-MS/MS method was developed and validated for quantifying the four artificial sweeteners in boreal lakes (n = 3) and rivers (n = 12). The highest concentrations of ACS, SAC, CYC and SCL were 9,600, 490, 210 and 1000 ng/L, respectively. ACS and SAC were detected in all studied samples, and CYC and SCL in 98% and 56% of the samples. Seasonal trends of ACS and SAC were observed in some rivers. ACS and SCL concentrations in rivers correlated linearly with population equivalents of the wastewater treatment plants in the catchment areas, whereas SAC and CYC concentrations depend more on the source. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Modifications to the NIST reference measurement procedure (RMP) for the determination of serum glucose by isotope dilution gas chromatography/mass spectrometry.

    PubMed

    Prendergast, Jocelyn L; Sniegoski, Lorna T; Welch, Michael J; Phinney, Karen W

    2010-07-01

    The definitive method (DM), now known as the reference measurement procedure (RMP), for the analysis of glucose in serum was originally published in 1982 by the National Institute of Standards and Technology (NIST). Over the years the method has been subject to a number of modifications to adapt to newer technologies and simplify sample preparation. We discuss here an adaptation of the method associated with serum glucose measurements using a modified isotope dilution gas chromatography/mass spectrometry (ID-GC/MS) method. NIST has used this modified method to certify the concentrations of glucose in SRM 965b, Glucose in Frozen Human Serum, and SRM 1950, Metabolites in Human Plasma. Comparison of results from the revised method with certified values for existing Standard Reference Materials (SRMs) demonstrated that these modifications have not affected the quality of the measurements, giving both good precision and accuracy, while reducing the sample preparation time by a day and a half.

  6. Bioaccumulation and trophic dilution of human pharmaceuticals across trophic positions of an effluent-dependent wadeable stream

    PubMed Central

    Du, Bowen; Haddad, Samuel P.; Luek, Andreas; Scott, W. Casan; Saari, Gavin N.; Kristofco, Lauren A.; Connors, Kristin A.; Rash, Christopher; Rasmussen, Joseph B.; Chambliss, C. Kevin; Brooks, Bryan W.

    2014-01-01

    Though pharmaceuticals are increasingly observed in a variety of organisms from coastal and inland aquatic systems, trophic transfer of pharmaceuticals in aquatic food webs have not been reported. In this study, bioaccumulation of select pharmaceuticals was investigated in a lower order effluent-dependent stream in central Texas, USA, using isotope dilution liquid chromatography–tandem mass spectrometry (MS). A fish plasma model, initially developed from laboratory studies, was tested to examine observed versus predicted internal dose of select pharmaceuticals. Pharmaceuticals accumulated to higher concentrations in invertebrates relative to fish; elevated concentrations of the antidepressant sertraline and its primary metabolite desmethylsertraline were observed in the Asian clam, Corbicula fluminea, and two unionid mussel species. Trophic positions were determined from stable isotopes (δ15N and δ13C) collected by isotope ratio-MS; a Bayesian mixing model was then used to estimate diet contributions towards top fish predators. Because diphenhydramine and carbamazepine were the only target compounds detected in all species examined, trophic magnification factors (TMFs) were derived to evaluate potential trophic transfer of both compounds. TMFs for diphenhydramine (0.38) and carbamazepine (1.17) indicated neither compound experienced trophic magnification, which suggests that inhalational and not dietary exposure represented the primary route of uptake by fish in this effluent-dependent stream. PMID:25313153

  7. Experimental design-based isotope-dilution SPME-GC/MS method development for the analysis of smoke flavouring products.

    PubMed

    Giri, Anupam; Zelinkova, Zuzana; Wenzl, Thomas

    2017-12-01

    For the implementation of Regulation (EC) No 2065/2003 related to smoke flavourings used or intended for use in or on foods a method based on solid-phase micro extraction (SPME) GC/MS was developed for the characterisation of liquid smoke products. A statistically based experimental design (DoE) was used for method optimisation. The best general conditions to quantitatively analyse the liquid smoke compounds were obtained with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre, 60°C extraction temperature, 30 min extraction time, 250°C desorption temperature, 180 s desorption time, 15 s agitation time, and 250 rpm agitation speed. Under the optimised conditions, 119 wood pyrolysis products including furan/pyran derivatives, phenols, guaiacol, syringol, benzenediol, and their derivatives, cyclic ketones, and several other heterocyclic compounds were identified. The proposed method was repeatable (RSD% <5) and the calibration functions were linear for all compounds under study. Nine isotopically labelled internal standards were used for improving quantification of analytes by compensating matrix effects that might affect headspace equilibrium and extractability of compounds. The optimised isotope dilution SPME-GC/MS based analytical method proved to be fit for purpose, allowing the rapid identification and quantification of volatile compounds in liquid smoke flavourings.

  8. Development of a QuEChERS-Based Stable-Isotope Dilution LC-MS/MS Method To Quantitate Ferulic Acid and Its Main Microbial and Hepatic Metabolites in Milk.

    PubMed

    Waterstraat, Martin; Hildebrand, Andreas; Rosler, Margit; Bunzel, Mirko

    2016-11-16

    Forage plants of the Poaceae family are grown as pasturage or used for the production of hay, straw, corn stover, etc. Although ferulic acid contents of grasses are generally high, the amount of ingested ferulic acid differs depending on the type of forage, resulting in varying contents of ferulic acid and its microbial and hepatic metabolites in milk. Concentrations and patterns of these metabolites may be used as markers to track different forages in livestock feeding. Therefore, we developed a stable isotope dilution assay to quantitate ferulic acid, 12 ferulic acid-based metabolites, p-coumaric acid, and cinnamic acid in milk. Because most analytes were not commercially available as stable isotope labeled standard compounds, they were synthesized as 13 C- or deuterium-labeled standard compounds. A modification of the QuEChERS method, a Quick, Easy, Cheap, Effective, Rugged, and Safe approach usually applied to analyze pesticides in plant-based products, was used to extract the phenolic acids from milk. Determination was carried out by LC-ESI-MS/MS in scheduled multiple reaction monitoring modus. By using three different milk samples, the applicability of the validated approach was demonstrated.

  9. Steps toward identifying a biogeochemical signal in non-equilibrium methane clumped isotope measurements

    NASA Astrophysics Data System (ADS)

    Douglas, P. M.; Eiler, J. M.; Sessions, A. L.; Dawson, K.; Walter Anthony, K. M.; Smith, D. A.; Lloyd, M. K.; Yanay, E.

    2016-12-01

    Microbially produced methane is a globally important greenhouse gas, energy source, and biological substrate. Methane clumped isotope measurements have recently been developed as a new analytical tool for understanding the source of methane in different environments. When methane forms in isotopic equilibrium clumped isotope values are determined by formation temperature, but in many cases microbial methane clumped isotope values deviate strongly from expected equilibrium values. Indeed, we observe a very wide range of clumped isotope values in microbial methane, which are likely strongly influenced by kinetic isotope effects, but thus far the biological and environmental parameters controlling this variability are not understood. We will present data from both culture experiments and natural environments to explore patterns of variability in non-equilibrium clumped isotope values on temporal and spatial scales. In methanogen batch cultures sampled at different time points along a growth curve we observe significant variability in clumped isotope values, with values decreasing from early to late exponential growth. Clumped isotope values then increase during stationary growth. This result is consistent with previous work suggesting that differences in the reversibility of methanogenesis related to metabolic rates control non-equilibrium clumped isotope values. Within single lakes in Alaska and Sweden we observe substantial variability in clumped isotope values on the order of 5‰. Lower clumped isotope values are associated with larger 2H isotopic fractionation between water and methane, which is also consistent with a kinetic isotope effect determined by the reversibility of methanogenesis. Finally, we analyzed a time-series clumped isotope compositions of methane emitted from two seeps in an Alaskan lake over several months. Temporal variability in these seeps is on the order of 2‰, which is much less than the observed spatial variability within the lake. Comparing carbon isotope fractionation between CO2 and CH4 with clumped isotope data suggests the temporal variability may result from changes in methane oxidation.

  10. Ring test evaluation of the detection of influenza A virus in swine oral fluids by real-time reverse-transcription polymerase chain reaction and virus isolation

    PubMed Central

    Goodell, Christa K.; Zhang, Jianqiang; Strait, Erin; Harmon, Karen; Patnayak, Devi; Otterson, Tracy; Culhane, Marie; Christopher-Hennings, Jane; Clement, Travis; Leslie-Steen, Pamela; Hesse, Richard; Anderson, Joe; Skarbek, Kevin; Vincent, Amy; Kitikoon, Pravina; Swenson, Sabrina; Jenkins-Moore, Melinda; McGill, Jodi; Rauh, Rolf; Nelson, William; O’Connell, Catherine; Shah, Rohan; Wang, Chong; Main, Rodger; Zimmerman, Jeffrey J.

    2016-01-01

    The probability of detecting influenza A virus (IAV) in oral fluid (OF) specimens was calculated for each of 13 assays based on real-time reverse-transcription polymerase chain reaction (rRT-PCR) and 7 assays based on virus isolation (VI). The OF specimens were inoculated with H1N1 or H3N2 IAV and serially diluted 10-fold (10−1 to 10−8). Eight participating laboratories received 180 randomized OF samples (10 replicates × 8 dilutions × 2 IAV subtypes plus 20 IAV-negative samples) and performed the rRT-PCR and VI procedure(s) of their choice. Analysis of the results with a mixed-effect logistic-regression model identified dilution and assay as variables significant (P < 0.0001) for IAV detection in OF by rRT-PCR or VI. Virus subtype was not significant for IAV detection by either rRT-PCR (P = 0.457) or VI (P = 0.101). For rRT-PCR the cycle threshold (Ct) values increased consistently with dilution but varied widely. Therefore, it was not possible to predict VI success on the basis of Ct values. The success of VI was inversely related to the dilution of the sample; the assay was generally unsuccessful at lower virus concentrations. Successful swine health monitoring and disease surveillance require assays with consistent performance, but significant differences in reproducibility were observed among the assays evaluated. PMID:26733728

  11. Fractionation of stable isotopes in perchlorate and nitrate during in situ biodegradation in a sandy aquifer

    USGS Publications Warehouse

    Hatzinger, P.B.; Bohlke, John Karl; Sturchio, N.C.; Gu, B.; Heraty, L.J.; Borden, R.C.

    2009-01-01

    An in situ experiment was performed in a shallow alluvial aquifer in Maryland to quantify the fractionation of stable isotopes in perchlorate (Cl and O) and nitrate (N and O) during biodegradation. An emulsified soybean oil substrate that was previously injected into this aquifer provided the electron donor necessary for biological perchlorate reduction and denitrification. During the field experiment, groundwater extracted from an upgradient well was pumped into an injection well located within the in situ oil barrier, and then groundwater samples were withdrawn for the next 30 h. After correction for dilution (using Br– as a conservative tracer of the injectate), perchlorate concentrations decreased by 78% and nitrate concentrations decreased by 82% during the initial 8.6 h after the injection. The observed ratio of fractionation effects of O and Cl isotopes in perchlorate (e18O/e37Cl) was 2.6, which is similar to that observed in the laboratory using pure cultures (2.5). Denitrification by indigenous bacteria fractionated O and N isotopes in nitrate at a ratio of ~0.8 (e18O/e15N), which is within the range of values reported previously for denitrification. However, the magnitudes of the individual apparent in situ isotope fractionation effects for perchlorate and nitrate were appreciably smaller than those reported in homogeneous closed systems (0.2 to 0.6 times), even after adjustment for dilution. These results indicate that (1) isotope fractionation factor ratios (e18O/e37Cl, e18O/e15N) derived from homogeneous laboratory systems (e.g. pure culture studies) can be used qualitatively to confirm the occurrence of in situ biodegradation of both perchlorate and nitrate, but (2) the magnitudes of the individual apparent e values cannot be used quantitatively to estimate the in situ extent of biodegradation of either anion.

  12. Fractionation of stable isotopes in perchlorate and nitrate during in situ biodegradation in a sandy aquifer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hatzinger, Paul B.; Bohlke, J. K.; Sturchio, N. C.

    An in situ experiment was performed in a shallow alluvial aquifer in Maryland to quantify the fractionation of stable isotopes in perchlorate (Cl and O) and nitrate (N and O) during biodegradation. An emulsified soybean oil substrate that was previously injected into this aquifer provided the electron donor necessary for biological perchlorate reduction and denitrification. During the field experiment, groundwater extracted from an upgradient well was pumped into an injection well located within the in situ oil barrier, and then groundwater samples were withdrawn for the next 30 h. After correction for dilution (using Br-as a conservative tracer of themore » injectate), perchlorate concentrations decreased by 78 % and nitrate concentrations decreased by 87 %, during the initial 8.6 h after the injection. The observed ratio of fractionation effects of O and Cl isotopes in perchlorate (ε18O/ε37Cl) was 2.6, which is similar to that observed in the laboratory using pure cultures (2.5). Denitrification by indigenous bacteria fractionated O and N isotopes in nitrate at a ratio of approximately 0.8 (ε18O/ε15N), which is within the range of values reported previously for denitrification. However, the magnitudes of the individual apparent in situ isotope fractionation effects for perchlorate and nitrate were appreciably smaller than those reported in homogeneous closed systems (0.2 to 0.6 times), even after adjustment for dilution. These results indicate that (1) isotope fractionation factor ratios (ε18O/ε37Cl, ε18O/ε15N) derived from homogeneous laboratory systems (e.g., pure culture studies) can be used qualitatively to confirm the occurrence of in situ biodegradation of both perchlorate and nitrate, but (2) the magnitudes of the individual apparent  values cannot be used quantitatively to estimate the in situ extent of biodegradation of either anion.« less

  13. Synergistic cosolubilization of omega-3 fatty acid esters and CoQ10 in dilutable microemulsions.

    PubMed

    Deutch-Kolevzon, Rivka; Aserin, Abraham; Garti, Nissim

    2011-10-01

    Water-dilutable microemulsions were prepared and loaded with two types of omega-3 fatty acid esters (omega-3 ethyl esters, OEE; and omega-3 triacylglycerides, OTG), each separately and together with ubiquinone (CoQ(10)). The microemulsions showed high and synergistic loading capabilities. The linear fatty acid ester (OEE) solubilization capacity was greater than that of the bulky and robust OTG. The location of the guest molecules within the microemulsions at any dilution point were determined by electrical conductivity, viscosity, DSC, SAXS, cryo-TEM, SD-NMR, and DLS. We found that OEE molecules pack well within the surfactant tails to form reverse micelles that gradually, upon water dilution, invert into bicontinuous phase and finally into O/W droplets. The CoQ(10) increases the stabilization and solubilization of the omega-3 fatty acid esters because it functions as a kosmotropic agent in the micellar system. The hydrophobic and bulky OTG molecule strongly interferes with the tail packing and spaces them significantly - mainly in the low and medium range water dilutions. When added to the micellar system, CoQ(10) forms some reverse hexagonal mesophases. The inversion into direct micelles is more difficult in comparison to the OEE system and requires additional water dilution. The OTG with or without CoQ(10) destabilizes the structures and decreases the solubilization capacity since it acts as a chaotropic agent to the micellar system and as a kosmotropic agent to hexagonal packing. These results explain the differences in the behavior of these molecules with vehicles that solubilize them in aqueous phases. Temperature disorders the bicontinuous structures and reduces the supersaturation of the system containing OEE with CoQ(10); as a result CoQ(10) crystallization is retarded. Copyright © 2011. Published by Elsevier Ireland Ltd.

  14. Effect of brewery wastewater obtained from different phases of treatment plant on seed germination of chickpea (Cicer arietinum), maize (Zea mays), and pigeon pea (Cajanus cajan).

    PubMed

    Salian, Rupa; Wani, Suhas; Reddy, Ramamohan; Patil, Mukund

    2018-03-01

    Brewing industry releases large quantities of wastewater after product generation. Brewery wastewater contains organic compounds which are biodegradable in nature. These biodegradable wastes can be recycled and reused and hence considered as suitable products for agriculture. But before using wastewater for agriculture, it is better to evaluate the phytotoxic effects of wastewater on crops. Hence, the main objective of this study is to evaluate the effects of brewery effluent on seed germination and growth parameters of selected crop species like chickpea (Cicer arietinum), maize (Zea mays), and pigeon pea (Cajanus cajan). Study comprised seven types of water treatments-tap water as control, diluted UASBR effluent (50% effluent + 50% distilled water): UASBR50, undiluted UASBR effluent: UASBR100, diluted TC effluent (50% effluent + 50% distilled water): ETP50,TC effluent without dilution: ETP100, 10% diluted reverse osmosis (RO10) reject (10% RO reject + 90% distilled water), and 25% diluted reverse osmosis(RO25) reject (25% RO reject + 75% distilled water) with three replications in completely randomized design. Germination test was performed in petri plates for 5 days. Parameters like germination percentage, germination rate index, seedling length, phytotoxicity index, seed vigor index, and biomass were calculated. All parameters decreased with increase in respective effluent concentration. Among all treatments, RO25 showed highest inhibitory effect on all three crops. Even though undiluted effluent of UASBR and ETP effluent showed positive effect on germination, seedling growth of three crops was promoted to the maximum by UASBR50 and ETP50. Hence, from the study, it was concluded that dilution of brewery effluent can be recommended before using it for irrigational purpose.

  15. Compound-specific carbon isotope analysis of instantaneous gas generated from shaly coal during hydrous pyrolysis

    NASA Astrophysics Data System (ADS)

    Tsai, Wen-Yu; Sun, Chih-Hsien; Huang, Wuu-Liang

    2010-05-01

    Isotopes of natural gases have provided important information for indicating their maturation, origins and influencing factors during the generation processes. In order to distinguish compositions of gas generated at different intervals of maturities, the present study investigates the variation of compound-specific carbon isotope (CSI) ratios of hydrocarbon gases from a shaly coal by instantaneous hydrous pyrolysis, during which the earlier generated gas was evacuated before the start of next maturation stage. The experiments were conducted at ten different maturity stages (0.65 to 2.02 % Ro) from a terrestrial shaly coal with 0.48 % Ro. The gas products were analyzed by GC-IR-MS. The results show that, in general, the δ13C values of methane (C1), ethane (C2), propane (C3) slightly increase, then decrease and finally increase with increasing maturities. This reverse phenomenon indicates the heterogeneous and complex compositions of the kerogen. The isotope compositions of gases exhibit three distinct clusters in natural gas plot of δ13C values versus 1/n (where n is carbon number of the gaseous molecule), corresponding to three different groups of maturity stages. By linking the same maturity stage of δ13C values, all lines show nearly parallel in each group with consistently reverse trend of δ13C3 < δ13C2 > δ13C1. These three distinct clusters were also observed in the cross plotting of iC4/nC4 versus iC5/nC5 isomer ratios. This may imply that the kerogen is composed of three discrete structural domains which were progressively cracked at three major groups of maturity stages. The reverse trend was inconsistent with data for gas collected cumulatively in most prior pyrolysis experiments and the linear relationship predicted from kinetic isotope effect (KIE) model. Although the non-linear relationship or reverse trend, δ13C3 < δ13C2, was also reported for some natural gases, it was interpreted as a result of mixing from different source rocks or other processes. Our results, however, suggest that this non-linear relationship or reverse phenomenon can also be attributed to the mixing of gases generated from different maturity stages solely from a single source formation. Therefore, our results provide a new interpretation for the variation of isotope data of the cumulative and instantaneous gases in hydrous pyrolysis experiments and isotope variation in natural gas.

  16. Cadmium determination in natural waters at the limit imposed by European legislation by isotope dilution and TiO2 solid-phase extraction.

    PubMed

    García-Ruiz, Silvia; Petrov, Ivan; Vassileva, Emilia; Quétel, Christophe R

    2011-11-01

    The cadmium content in surface water is regulated by the last European Water Framework Directive to a maximum between 0.08 and 0.25 μg L(-1) depending on the water type and hardness. Direct measurement of cadmium at this low level is not straightforward in real samples, and we hereby propose a validated method capable of addressing cadmium content below μg L(-1) level in natural water. It is based on solid-phase extraction using TiO(2) nanoparticles as solid sorbent (0.05 g packed in mini-columns) to allow the separation and preconcentration of cadmium from the sample, combined to direct isotope dilution and detection by inductively coupled plasma mass spectrometry (ID-ICP-MS). The extraction setup is miniaturised and semi-automated to reduce risks of sample contamination and improve reproducibility. Procedural blanks for the whole measurement process were 5.3 ± 2.8 ng kg(-1) (1 s) for 50 g of ultrapure water preconcentrated ten times. Experimental conditions influencing the separation (including loading pH, sample flow rates, and acid concentration in the eluent) were evaluated. With isotope dilution the Cd recovery rate does not have to be evaluated carefully. Moreover, the mathematical model associated to IDMS is known, and provides transparency for the uncertainty propagation. Our validation protocol was in agreement with guidelines of the ISO/IEC 17025 standard (chapter 5.4.5). Firstly, we assessed the experimental factors influencing the final result. Secondly, we compared the isotope ratios measured after our separation procedure to the reference values obtained with a different protocol for the digested test material IMEP-111 (mineral feed). Thirdly, we analysed the certified reference material BCR-609 (groundwater). Finally, combined uncertainties associated to our results were estimated according to ISO-GUM guidelines (typically, 3-4% k = 2 for a cadmium content of around 100 ng kg(-1)). We applied the developed method to the groundwater and wastewater samples ERM-CA615 and BCR-713, respectively, and results agreed with certificate values within uncertainty statements.

  17. Unusual Recharge Processes near Arroyos of the Rio Grande Aquifer, El Paso/Juarez Area

    NASA Astrophysics Data System (ADS)

    Merino, M.; Hibbs, B. J.; Hogan, J.; Eastoe, C. J.; Druhan, J.

    2005-12-01

    The twin-cities of El Paso and Juarez share the water resources of the Hueco Bolson aquifer and overlying Rio Grande aquifer. Both aquifers span the international border between Mexico and the United States. Salinity in the Rio Grande aquifer varies widely, some parts of the shallow aquifer containing less than 1,000 mg/L total dissolved solids (TDS), other parts of the aquifer exceeding 5,000 mg/L TDS. One sizable part of the "Lower Valley" area, approximately 45 km below El Paso contains very dilute water near the outer edge of the floodplain. Historically it had been thought that the dilute waters in this location were derived from recharge from arroyos that drained proximal parts of the Hueco Bolson. Instead, our hydrogen and oxygen isotope data and carbon-14 data indicate that these dilute waters were derived from pre-dam infiltration of the Rio Grande. Relatively light and slightly evaporated pre-dam waters (-11.5 del O18) at the arroyos are also relatively young (60 to 90 percent modern carbon), tagging them as runoff waters from pre-dam snowmelt in Colorado. These isotopically light waters are found up to 110 meters beneath land surface. Prior to Rio Grande rectification and channelization of the mid-1930's, the Rio Grande flowed near the outer edge of the floodplain where these pre-dam, dilute waters are found at depth. Review of predevelopment drill stem tests indicated a permeable zone about 150 to 230 meters deep that had a lower hydraulic head than the overlying Rio Grande aquifer. The permeable zone acted as a predevelopment sink for flow that induced recharge from the Rio Grande and Rio Grande aquifer. Thus, we can account for local predevelopment recharge of the Rio Grande aquifer from infiltration of dilute water from the Rio Grande prior to the historic era of channel rectification, and not from recharge from flanking arroyos as had been postulated by previous researchers.

  18. Influence of uncertainties of isotopic composition of the reprocessed uranium on effectiveness of its enrichment in gas centrifuge cascades

    NASA Astrophysics Data System (ADS)

    Smirnov, A. Yu; Mustafin, A. R.; Nevinitsa, V. A.; Sulaberidze, G. A.; Dudnikov, A. A.; Gusev, V. E.

    2017-01-01

    The effect of the uncertainties of the isotopic composition of the reprocessed uranium on its enrichment process in gas centrifuge cascades while diluting it by adding low-enriched uranium (LEU) and waste uranium. It is shown that changing the content of 232U and 236U isotopes in the initial reprocessed uranium within 15% (rel.) can significantly change natural uranium consumption and separative work (up to 2-3%). However, even in case of increase of these parameters is possible to find the ratio of diluents, where the cascade with three feed flows (depleted uranium, LEU and reprocessed uranium) will be more effective than ordinary separation cascade with one feed point for producing LEU from natural uranium.

  19. Dietary change and stable isotopes: a model of growth and dormancy in cave bears.

    PubMed Central

    Lidén, K; Angerbjörn, A

    1999-01-01

    In order to discuss dietary change over time by the use of stable isotopes, it is necessary to sort out the underlying processes in isotopic variation. Together with the dietary signal other processes have been investigated, namely metabolic processes, collagen turnover and physical growth. However, growth and collagen turnover time have so far been neglected in dietary reconstruction based on stable isotopes. An earlier study suggested that cave bears (Ursus spelaeus) probably gave birth to cubs during dormancy. We provide an estimate of the effect on stable isotopes of growth and metabolism and discuss collagen turnover in a population of cave bears. Based on a quantitative model, we hypothesized that bear cubs lactated their mothers during their first and second winters, but were fed solid food together with lactation during their first summer. This demonstrates the need to include physical growth, metabolism and collagen turnover in dietary reconstruction. Whereas the effects of diet and metabolism are due to fractionation, growth and collagen turnover are dilution processes. PMID:10518325

  20. Constraints on Martian Differentiation Processes from Rb-Sr and Sm-Nd Isotopic Analyses of the Basaltic Shergottite QUE 94201

    NASA Technical Reports Server (NTRS)

    Borg, Lars E.; Nyquist, Larry E.; Taylor, Larry A.; Wiesmann, Henry; Shih, Chi-Y.

    1997-01-01

    Isotopic analyses of mineral, leachate, and whole rock fractions from the Martian shergottite meteorite QUE 94201 yield Rb-Sr and Sm-Nd crystallization ages of 327 +/- 12 and 327 +/- 19 Ma, respectively. These ages are concordant, although the isochrons are defined by different fractions within the meteorite. Comparison of isotope dilution Sm and Nd data for the various QUE 94201 fractions with in situ ion microprobe data for QUE 94201 minerals from the literature demonstrate the presence of a leachable crustal component in the meteorite. This component is likely to have been added to QUE 94201 by secondary alteration processes on Mars, and can affect the isochrons by selectively altering the isotopic systematics of the leachates and some of the mineral fractions. The absence of crustal recycling processes on Mars may preserve the geochemical evidence for early differentiation and the decoupling of the Rb-Sr and Sm-Nd isotopic systems, underscoring one of the fundamental differences between geologic processes on Mars and the Earth.

  1. Neodymium and strontium isotopic study of Australasian tektites - New constraints on the provenance and age of target materials

    NASA Technical Reports Server (NTRS)

    Blum, Joel D.; Papanastassiou, D. A.; Wasserburg, G. J.; Koeberl, C.

    1992-01-01

    The Nd and Sr isotopic compositions of Australasian tectites (including two flanged Australian tectites, two low-SiO2 Muong Nong-type tectites, and three high-SiO2 Muong Nong-type tectites) and the Nd, Sm, Sr, and Rb concentrations were investigated by isotope-dilution thermal ionization mass spectrometry, and the Sm-Nd and Rb-Sr isotope systematics were used to study the characteristics of the parental material. It is shown that the Nd and Sr isotopic data provide evidence that all Australasian tektites were derived from a single sedimentary formation with a narrow range of stratigraphic ages close to 170 Ma. It is suggested that all of the Australasian tektites were derived from a single impact event and that the australites represent the upper part of a melt sheet ejected at high velocity, whereas the indochinites represent melts formed at a lower level in the target material distributed closer to the area of the impact.

  2. ISOTOPE DILUTION ANALYSIS OF BROMATE IN DRINKING WATER MATRIXES BY ION CHROMATOGRAPHY WITH INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRIC DETECTION

    EPA Science Inventory

    Bromate is a disinfection byproduct in drinking water which is formed during the ozonation of source water containing bromide. This paper described the analysis of bromate via ion chromatography-inductively coupled plasma mass spectrometry. The separation of bromate from interfer...

  3. Analysis of thyroid hormones in biological samples using stable isotope dilution liquid chromatography-tandem mass spectrometry

    EPA Science Inventory

    This poster presentation will describe analytical chemistry methods for measuring thyroid hormones and related precursors and metabolites in very small tissue or plasma samples. These methods are amenable to measure thyroid hormones in amphibian tadpoles or small mammals used as ...

  4. Nature and Analysis of Chemical Species.

    ERIC Educational Resources Information Center

    Shuman, Mark S.; Fogleman, Wavell W.

    1978-01-01

    Presents a literature review of the nature and analysis of chemical species in water, covering publications of 1976-77. This review is concerned with inorganics, and it covers: (1) electrochemical analysis; (2) spectroscopy; (3) neutron activation, radiochemical analysis, and isotope dilution. A list of 262 references is also presented. (HM)

  5. High Resolution Gamma Ray Analysis of Medical Isotopes

    NASA Astrophysics Data System (ADS)

    Chillery, Thomas

    2015-10-01

    Compton-suppressed high-purity Germanium detectors at the University of Massachusetts Lowell have been used to study medical radioisotopes produced at Brookhaven Linac Isotope Producer (BLIP), in particular isotopes such as Pt-191 used for cancer therapy in patients. The ability to precisely analyze the concentrations of such radio-isotopes is essential for both production facilities such as Brookhaven and consumer hospitals across the U.S. Without accurate knowledge of the quantities and strengths of these isotopes, it is possible for doctors to administer incorrect dosages to patients, thus leading to undesired results. Samples have been produced at Brookhaven and shipped to UML, and the advanced electronics and data acquisition capabilities at UML have been used to extract peak areas in the gamma decay spectra. Levels of Pt isotopes in diluted samples have been quantified, and reaction cross-sections deduced from the irradiation parameters. These provide both cross checks with published work, as well as a rigorous quantitative framework with high quality state-of-the-art detection apparatus in use in the experimental nuclear physics community.

  6. Method And Apparatus For Production Of Bi-213 From The Activity Ac-225 Source

    DOEpatents

    Egorov, Oleg B.; O'Hara, Matthew J.

    2005-12-06

    A method and apparatus for isolating and purifying a .sup.213 Bi radioactive isotope from an .sup.225 Ac source using a primary column and a primary sorbent which preferentially retains .sup.225 Ac over .sup.213 Bi when exposed to a compatible solvent in combination with a secondary column having a secondary sorbent which retains .sup.213 Bi when exposed to a mixture of the compatible solvent and .sup.213 Bi. A "compatible solvent" is a solvent which will preferentially remove .sup.213 Bi radioactive isotopes from a primary sorbent without removing .sup.225 Ac radioactive isotopes, and then allow .sup.213 Bi radioactive isotopes removed from the primary sorbent to be retained on a secondary sorbent, without having to dilute or otherwise chemically or physically modify the compatible solvent in between exposure to the primary and secondary sorbents.

  7. Isotope Labeling for Solution and Solid-State NMR Spectroscopy of Membrane Proteins

    PubMed Central

    Verardi, Raffaello; Traaseth, Nathaniel J.; Masterson, Larry R.; Vostrikov, Vitaly V.; Veglia, Gianluigi

    2013-01-01

    In this chapter, we summarize the isotopic labeling strategies used to obtain high-quality solution and solid-state NMR spectra of biological samples, with emphasis on integral membrane proteins (IMPs). While solution NMR is used to study IMPs under fast tumbling conditions, such as in the presence of detergent micelles or isotropic bicelles, solid-state NMR is used to study the structure and orientation of IMPs in lipid vesicles and bilayers. In spite of the tremendous progress in biomolecular NMR spectroscopy, the homogeneity and overall quality of the sample is still a substantial obstacle to overcome. Isotopic labeling is a major avenue to simplify overlapped spectra by either diluting the NMR active nuclei or allowing the resonances to be separated in multiple dimensions. In the following we will discuss isotopic labeling approaches that have been successfully used in the study of IMPs by solution and solid-state NMR spectroscopy. PMID:23076578

  8. Pb and Sr isotope measurements by inductively coupled plasma mass spectrometer: efficient time management for precision improvement

    NASA Astrophysics Data System (ADS)

    Monna, F.; Loizeau, J.-L.; Thomas, B. A.; Guéguen, C.; Favarger, P.-Y.

    1998-08-01

    One of the factors limiting the precision of inductively coupled plasma mass spectrometry is the counting statistics, which depend upon acquisition time and ion fluxes. In the present study, the precision of the isotopic measurements of Pb and Sr is examined. The time of measurement is optimally shared for each isotope, using a mathematical simulation, to provide the lowest theoretical analytical error. Different algorithms of mass bias correction are also taken into account and evaluated in term of improvement of overall precision. Several experiments allow a comparison of real conditions with theory. The present method significantly improves the precision, regardless of the instrument used. However, this benefit is more important for equipment which originally yields a precision close to that predicted by counting statistics. Additionally, the procedure is flexible enough to be easily adapted to other problems, such as isotopic dilution.

  9. Differences in energy expenditures and growth dilution explain higher PCB concentrations in male summer flounder

    USGS Publications Warehouse

    Madenjian, Charles P.; Jensen, Olaf P.; Rediske, Richard R.; O'Keefe, James P.; Vastano, Anthony R.; Pothoven, Steven A.

    2016-01-01

    Comparison of polychlorinated biphenyl (PCB) concentrations between the sexes of mature fish may reveal important behavioral and physiological differences between the sexes. We determined whole-fish PCB concentrations in 23 female summer flounder Paralichthys dentatus and 27 male summer flounder from New Jersey coastal waters. To investigate the potential for differences in diet or habitat utilization between the sexes, carbon and nitrogen stable isotope ratios were also determined. In 5 of the 23 female summer flounder, PCB concentrations in the somatic tissue and ovaries were determined. In addition, we used bioenergetics modeling to assess the contribution of the growth dilution effect to the observed difference in PCB concentrations between the sexes. Whole-fish PCB concentrations for females and males averaged 87 and 124 ng/g, respectively; thus males were 43% higher in PCB concentration compared with females. Carbon and nitrogen stable isotope ratios did not significantly differ between the sexes, suggesting that diet composition and habitat utilization did not vary between the sexes. Based on PCB determinations in the somatic tissue and ovaries, we predicted that PCB concentration of females would increase by 0.6%, on average, immediately after spawning due to release of eggs. Thus, the change in PCB concentration due to release of eggs did not explain the higher PCB concentrations observed in males. Bioenergetics modeling results indicated that the growth dilution effect could account for males being 19% higher in PCB concentration compared with females. Thus, the bulk of the observed difference in PCB concentrations between the sexes was not explained by growth dilution. We concluded that a higher rate of energy expenditure in males, stemming from greater activity and a greater resting metabolic rate, was most likely the primary driver for the observed difference in PCB concentrations between the sexes.

  10. Differences in Energy Expenditures and Growth Dilution Explain Higher PCB Concentrations in Male Summer Flounder.

    PubMed

    Madenjian, Charles P; Jensen, Olaf P; Rediske, Richard R; O'Keefe, James P; Vastano, Anthony R; Pothoven, Steven A

    2016-01-01

    Comparison of polychlorinated biphenyl (PCB) concentrations between the sexes of mature fish may reveal important behavioral and physiological differences between the sexes. We determined whole-fish PCB concentrations in 23 female summer flounder Paralichthys dentatus and 27 male summer flounder from New Jersey coastal waters. To investigate the potential for differences in diet or habitat utilization between the sexes, carbon and nitrogen stable isotope ratios were also determined. In 5 of the 23 female summer flounder, PCB concentrations in the somatic tissue and ovaries were determined. In addition, we used bioenergetics modeling to assess the contribution of the growth dilution effect to the observed difference in PCB concentrations between the sexes. Whole-fish PCB concentrations for females and males averaged 87 and 124 ng/g, respectively; thus males were 43% higher in PCB concentration compared with females. Carbon and nitrogen stable isotope ratios did not significantly differ between the sexes, suggesting that diet composition and habitat utilization did not vary between the sexes. Based on PCB determinations in the somatic tissue and ovaries, we predicted that PCB concentration of females would increase by 0.6%, on average, immediately after spawning due to release of eggs. Thus, the change in PCB concentration due to release of eggs did not explain the higher PCB concentrations observed in males. Bioenergetics modeling results indicated that the growth dilution effect could account for males being 19% higher in PCB concentration compared with females. Thus, the bulk of the observed difference in PCB concentrations between the sexes was not explained by growth dilution. We concluded that a higher rate of energy expenditure in males, stemming from greater activity and a greater resting metabolic rate, was most likely the primary driver for the observed difference in PCB concentrations between the sexes.

  11. Differences in Energy Expenditures and Growth Dilution Explain Higher PCB Concentrations in Male Summer Flounder

    PubMed Central

    Madenjian, Charles P.; Jensen, Olaf P.; Rediske, Richard R.; O’Keefe, James P.; Vastano, Anthony R.; Pothoven, Steven A.

    2016-01-01

    Comparison of polychlorinated biphenyl (PCB) concentrations between the sexes of mature fish may reveal important behavioral and physiological differences between the sexes. We determined whole-fish PCB concentrations in 23 female summer flounder Paralichthys dentatus and 27 male summer flounder from New Jersey coastal waters. To investigate the potential for differences in diet or habitat utilization between the sexes, carbon and nitrogen stable isotope ratios were also determined. In 5 of the 23 female summer flounder, PCB concentrations in the somatic tissue and ovaries were determined. In addition, we used bioenergetics modeling to assess the contribution of the growth dilution effect to the observed difference in PCB concentrations between the sexes. Whole-fish PCB concentrations for females and males averaged 87 and 124 ng/g, respectively; thus males were 43% higher in PCB concentration compared with females. Carbon and nitrogen stable isotope ratios did not significantly differ between the sexes, suggesting that diet composition and habitat utilization did not vary between the sexes. Based on PCB determinations in the somatic tissue and ovaries, we predicted that PCB concentration of females would increase by 0.6%, on average, immediately after spawning due to release of eggs. Thus, the change in PCB concentration due to release of eggs did not explain the higher PCB concentrations observed in males. Bioenergetics modeling results indicated that the growth dilution effect could account for males being 19% higher in PCB concentration compared with females. Thus, the bulk of the observed difference in PCB concentrations between the sexes was not explained by growth dilution. We concluded that a higher rate of energy expenditure in males, stemming from greater activity and a greater resting metabolic rate, was most likely the primary driver for the observed difference in PCB concentrations between the sexes. PMID:26794728

  12. Labile pools of Pb in vegetable-growing soils investigated by an isotope dilution method and its influence on soil pH.

    PubMed

    Xie, Hong; Huang, Zhi-Yong; Cao, Ying-Lan; Cai, Chao; Zeng, Xiang-Cheng; Li, Jian

    2012-08-01

    Pollution of Pb in the surface of agricultural soils is of increasing concern due to its serious impact on the plant growth and the human health through the food chain. However, the mobility, activity and bioavailability of Pb rely mainly on its various chemical species in soils. In the present study, E and L values, the labile pools of isotopically exchangeable Pb, were estimated using the method of isotope dilution in three vegetable-growing soils. The experiments involved adding a stable enriched isotope ((206)Pb > 96%) to a soil suspension and to soils in which plants are subsequently grown, the labile pools of Pb were then estimated by measuring the isotopic composition of Pb in soil solutions and in the plant tissues, respectively. In addition, the correlation of E values and soil pH was investigated at the ranges of pH 4.5-7.0. The amount of labile Pb in soils was also estimated using different single chemical extractants and a modified BCR approach. The results showed that after spiking the enriched isotopes of (206)Pb (>96%) for 24 hours an equilibration of isotopic exchanges in soil suspensions was achieved, and the isotope ratios of (208)Pb/(206)Pb measured at that time was used for calculating the E(24 h) values. The labile pools of Pb by %E(24 h) values, ranging from 53.2% to 61.7% with an average 57%, were found to be significantly higher (p < 0.05) than the values estimated with L values, single chemical extractants and the Σ(BCR) values obtained with the BCR approach, respectively. A strong negative correlation (R(2) = 0.984) between E(24 h) values and soil pH was found in the tested soil sample. The results indicate that the %E(24 h) value can more rapidly and easily predict the labile pools of Pb in soils compared with L values, but it might be readily overestimated because of the artificial soil acidity derived from the spiked isotopic tracer and the excess of spiked enriched isotopes. The results also suggest that the amounts of Pb extracted with EDTA and the Σ(BCR) values extracted with the modified BCR approach are helpful to detect the labile pools of Pb in soils. In addition, the negative correlation between soil pH and the labile pools of Pb in soils may be useful for further remediation to reduce the bioavailability of Pb in contaminated soils.

  13. Fractionation of stable isotopes in perchlorate and nitrate during in situ biodegradation in a sandy aquifer

    USGS Publications Warehouse

    Hatzinger, P.B.; Böhlke, J.K.; Sturchio, N.C.; Gu, B.; Heraty, L.J.; Borden, R.C.

    2009-01-01

    Environmental context. Perchlorate (ClO4-) and nitrate (NO3-) are common co-contaminants in groundwater, with both natural and anthropogenic sources. Each of these compounds is biodegradable, so in situ enhanced bioremediation is one alternative for treating them in groundwater. Because bacteria typically fractionate isotopes during biodegradation, stable isotope analysis is increasingly used to distinguish this process from transport or mixing-related decreases in contaminant concentrations. However, for this technique to be useful in the field to monitor bioremediation progress, isotope fractionation must be quantified under relevant environmental conditions. In the present study, we quantify the apparent in situ fractionation effects for stable isotopes in ClO4- (Cl and O) and NO3- (N and O) resulting from biodegradation in an aquifer. Abstract. An in situ experiment was performed in a shallow alluvial aquifer in Maryland to quantify the fractionation of stable isotopes in perchlorate (Cl and O) and nitrate (N and O) during biodegradation. An emulsified soybean oil substrate that was previously injected into this aquifer provided the electron donor necessary for biological perchlorate reduction and denitrification. During the field experiment, groundwater extracted from an upgradient well was pumped into an injection well located within the in situ oil barrier, and then groundwater samples were withdrawn for the next 30 h. After correction for dilution (using Br- as a conservative tracer of the injectate), perchlorate concentrations decreased by 78% and nitrate concentrations decreased by 82% during the initial 8.6 h after the injection. The observed ratio of fractionation effects of O and Cl isotopes in perchlorate (18O/37Cl) was 2.6, which is similar to that observed in the laboratory using pure cultures (2.5). Denitrification by indigenous bacteria fractionated O and N isotopes in nitrate at a ratio of ???0.8 (18O/15N), which is within the range of values reported previously for denitrification. However, the magnitudes of the individual apparent in situ isotope fractionation effects for perchlorate and nitrate were appreciably smaller than those reported in homogeneous closed systems (0.2 to 0.6 times), even after adjustment for dilution. These results indicate that (1) isotope fractionation factor ratios (18O/37Cl, 18O/15N) derived from homogeneous laboratory systems (e.g. pure culture studies) can be used qualitatively to confirm the occurrence of in situ biodegradation of both perchlorate and nitrate, but (2) the magnitudes of the individual apparent values cannot be used quantitatively to estimate the in situ extent of biodegradation of either anion. ?? CSIRO 2009.

  14. FE and MG Isotopic Analyses of Isotopically Unusual Presolar Silicate Grains

    NASA Technical Reports Server (NTRS)

    Nguyen, A. N.; Messenger, S.; Ito, M.; Rahman, Z.

    2011-01-01

    Interstellar and circumstellar silicate grains are thought to be Mg-rich and Fe-poor, based on astronomical observations and equilibrium condensation models of silicate dust formation in stellar outflows. On the other hand, presolar silicates isolated from meteorites have surprisingly high Fe contents and few Mg-rich grains are observed. The high Fe contents in meteoritic presolar silicates may indicate they formed by a non-equilibrium condensation process. Alternatively, the Fe in the stardust grains could have been acquired during parent body alteration. The origin of Fe in presolar silicates may be deduced from its isotopic composition. Thus far, Fe isotopic measurements of presolar silicates are limited to the Fe-54/Fe-56 ratios of 14 grains. Only two slight anomalies (albeit solar within error) were observed. However, these measurements suffered from contamination of Fe from the adjacent meteorite matrix, which diluted any isotopic anomalies. We have isolated four presolar silicates having unusual O isotopic compositions by focused ion beam (FIB) milling and obtained their undiluted Mg and Fe isotopic compositions. These compositions help to identify the grains stellar sources and to determine the source of Fe in the grains.

  15. Production of isotopically labeled standards from a uniformly labeled precursor for quantitative volatile metabolomic studies.

    PubMed

    Gómez-Cortés, Pilar; Brenna, J Thomas; Sacks, Gavin L

    2012-06-19

    Optimal accuracy and precision in small-molecule profiling by mass spectrometry generally requires isotopically labeled standards chemically representative of all compounds of interest. However, preparation of mixed standards from commercially available pure compounds is often prohibitively expensive and time-consuming, and many labeled compounds are not available in pure form. We used a single-prototype uniformly labeled [U-(13)C]compound to generate [U-(13)C]-labeled volatile standards for use in subsequent experimental profiling studies. [U-(13)C]-α-Linolenic acid (18:3n-3, ALA) was thermally oxidized to produce labeled lipid degradation volatiles which were subsequently characterized qualitatively and quantitatively. Twenty-five [U-(13)C]-labeled volatiles were identified by headspace solid-phase microextraction-gas chromatography/time-of-flight mass spectrometry (HS-SPME-GC/TOF-MS) by comparison of spectra with unlabeled volatiles. Labeled volatiles were quantified by a reverse isotope dilution procedure. Using the [U-(13)C]-labeled standards, limits of detection comparable to or better than those of previous HS-SPME reports were achieved, 0.010-1.04 ng/g. The performance of the [U-(13)C]-labeled volatile standards was evaluated using a commodity soybean oil (CSO) oxidized at 60 °C from 0 to 15 d. Relative responses of n-decane, an unlabeled internal standard otherwise absent from the mixture, and [U-(13)C]-labeled oxidation products changed by up to 8-fold as the CSO matrix was oxidized, demonstrating that reliance on a single standard in volatile profiling studies yields inaccurate results due to changing matrix effects. The [U-(13)C]-labeled standard mixture was used to quantify 25 volatiles in oxidized CSO and low-ALA soybean oil with an average relative standard deviation of 8.5%. Extension of this approach to other labeled substrates, e.g., [U-(13)C]-labeled sugars and amino acids, for profiling studies should be feasible and can dramatically improve quantitative results compared to use of a single standard.

  16. A noncoding melanophilin gene (MLPH) SNP at the splice donor of exon 1 represents a candidate causal mutation for coat color dilution in dogs.

    PubMed

    Drögemüller, Cord; Philipp, Ute; Haase, Bianca; Günzel-Apel, Anne-Rose; Leeb, Tosso

    2007-01-01

    Coat color dilution in several breeds of dog is characterized by a specific pigmentation phenotype and sometimes accompanied by hair loss and recurrent skin inflammation, the so-called color dilution alopecia or black hair follicular dysplasia. Coat color dilution (d) is inherited as a Mendelian autosomal recessive trait. In a previous study, MLPH polymorphisms showed perfect cosegregation with the dilute phenotype within breeds. However, different dilute haplotypes were found in different breeds, and no single polymorphism was identified in the coding sequence that was likely to be causative for the dilute phenotype. We resequenced the 5'-region of the canine MLPH gene and identified a strong candidate single nucleotide polymorphism within the nontranslated exon 1, which showed perfect association to the dilute phenotype in 65 dilute dogs from 7 different breeds. The A/G polymorphism is located at the last nucleotide of exon 1 and the mutant A-allele is predicted to reduce splicing efficiency 8-fold. An MLPH mRNA expression study using quantitative reverse transcriptase-polymerase chain reaction confirmed that dd animals had only about approximately 25% of the MLPH transcript compared with DD animals. These results provide preliminary evidence that the reported regulatory MLPH mutation might represent a causal mutation for coat color dilution in dogs.

  17. Semi-automated solid phase extraction method for the mass spectrometric quantification of 12 specific metabolites of organophosphorus pesticides, synthetic pyrethroids, and select herbicides in human urine.

    PubMed

    Davis, Mark D; Wade, Erin L; Restrepo, Paula R; Roman-Esteva, William; Bravo, Roberto; Kuklenyik, Peter; Calafat, Antonia M

    2013-06-15

    Organophosphate and pyrethroid insecticides and phenoxyacetic acid herbicides represent important classes of pesticides applied in commercial and residential settings. Interest in assessing the extent of human exposure to these pesticides exists because of their widespread use and their potential adverse health effects. An analytical method for measuring 12 biomarkers of several of these pesticides in urine has been developed. The target analytes were extracted from one milliliter of urine by a semi-automated solid phase extraction technique, separated from each other and from other urinary biomolecules by reversed-phase high performance liquid chromatography, and detected using tandem mass spectrometry with isotope dilution quantitation. This method can be used to measure all the target analytes in one injection with similar repeatability and detection limits of previous methods which required more than one injection. Each step of the procedure was optimized to produce a robust, reproducible, accurate, precise and efficient method. The required selectivity and sensitivity for trace-level analysis (e.g., limits of detection below 0.5ng/mL) was achieved using a narrow diameter analytical column, higher than unit mass resolution for certain analytes, and stable isotope labeled internal standards. The method was applied to the analysis of 55 samples collected from adult anonymous donors with no known exposure to the target pesticides. This efficient and cost-effective method is adequate to handle the large number of samples required for national biomonitoring surveys. Published by Elsevier B.V.

  18. [Determination of endogenous agmatine in rat plasma by isotope dilution-gas chromatography-mass spectrometry].

    PubMed

    Qiu, Zhongli; Lin, Ying; Xiong, Zhili; Xie, Jianwei

    2014-07-01

    A method for the determination of endogenous agmatine in rat plasma was developed by isotope dilution-gas chromatography-negative chemical ionization mass spectrometry (GC-NCI/MS). The plasma samples were analyzed after protein precipitation, evaporation, derivatization by hexafluoroacetone (HFAA), and clean-up on a Florisil SPE column. The GC-MS analysis utilized stable isotope d8-agmatine as internal standard. The samples after treatme were tested by negative chemical ionization with selected ion monitoring (SIM) which was set at m/z 492 (molecular ion of agmatine) and m/z 500 (molecular ion of internal standard). The limit of detection (LOD) of agmatine standard solution was 0.005 7 ng/mL. The calibration curve of the agmatine spiked in rat plasma showed a good linear relationship at the range of 1.14-57.0 ng/mL (r = 0.997). The recoveries of agmatine spiked in rat plasma ranged from 92.3% to 109.8%. Inter-day and intra-day precisions were less than 15%. The average concentration level of agmatine in rat plasma was (22 +/- 9) ng/mL, and there was no significant difference between male and female SD rats (p > 0.05). The method is high sensitive and specific, and can be used for the determination of endogenous agmatine in plasma. It provides a strong support for the subsequent research of agmatine.

  19. Introducing AAA-MS, a rapid and sensitive method for amino acid analysis using isotope dilution and high-resolution mass spectrometry.

    PubMed

    Louwagie, Mathilde; Kieffer-Jaquinod, Sylvie; Dupierris, Véronique; Couté, Yohann; Bruley, Christophe; Garin, Jérôme; Dupuis, Alain; Jaquinod, Michel; Brun, Virginie

    2012-07-06

    Accurate quantification of pure peptides and proteins is essential for biotechnology, clinical chemistry, proteomics, and systems biology. The reference method to quantify peptides and proteins is amino acid analysis (AAA). This consists of an acidic hydrolysis followed by chromatographic separation and spectrophotometric detection of amino acids. Although widely used, this method displays some limitations, in particular the need for large amounts of starting material. Driven by the need to quantify isotope-dilution standards used for absolute quantitative proteomics, particularly stable isotope-labeled (SIL) peptides and PSAQ proteins, we developed a new AAA assay (AAA-MS). This method requires neither derivatization nor chromatographic separation of amino acids. It is based on rapid microwave-assisted acidic hydrolysis followed by high-resolution mass spectrometry analysis of amino acids. Quantification is performed by comparing MS signals from labeled amino acids (SIL peptide- and PSAQ-derived) with those of unlabeled amino acids originating from co-hydrolyzed NIST standard reference materials. For both SIL peptides and PSAQ standards, AAA-MS quantification results were consistent with classical AAA measurements. Compared to AAA assay, AAA-MS was much faster and was 100-fold more sensitive for peptide and protein quantification. Finally, thanks to the development of a labeled protein standard, we also extended AAA-MS analysis to the quantification of unlabeled proteins.

  20. A new thorium-229 reference material

    DOE PAGES

    Essex, Richard M.; Mann, Jaqueline L.; Williams, Ross W.; ...

    2017-07-27

    A new reference material was characterized for 229Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230Th)/n( 229Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232Th)/n( 229Th) ratio is (3.815 ± 0.092)×10 -4.

  1. Chromatographic hydrogen isotope separation

    DOEpatents

    Aldridge, Frederick T.

    1981-01-01

    Intermetallic compounds with the CaCu.sub.5 type of crystal structure, particularly LaNiCo.sub.4 and CaNi.sub.5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation colum. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale mutli-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  2. A new thorium-229 reference material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Essex, Richard M.; Mann, Jaqueline L.; Williams, Ross W.

    A new reference material was characterized for 229Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230Th)/n( 229Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232Th)/n( 229Th) ratio is (3.815 ± 0.092)×10 -4.

  3. Chromatographic hydrogen isotope separation

    DOEpatents

    Aldridge, F.T.

    Intermetallic compounds with the CaCu/sub 5/ type of crystal structure, particularly LaNiCo/sub 4/ and CaNi/sub 5/, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation column. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale multi-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen cn produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  4. MULTISPECIES INVESTIGATION OF NITROGEN AND OXYGEN ISOTOPES IN A CONTAMINATED GROUND-WATER PLUME UNDERGOING DILUTION, OXYGEN CONSUMPTION, AND DENITRIFICATION, CAPE COD, MA. (R824787)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  5. Reactions of Solvated Ions Final Report

    DOE R&D Accomplishments Database

    Taube, H.

    1962-09-24

    Brief summaries are presented on isotopic dilution studies on salts dissolved in CH{sub 3}OH, studies on metal and metal salts in solvents of the amine type, and studies on phosphato complexes of the pentammine Co(III) series. A list of papers published on reactions of solvated ions is included. (N.W.R.)

  6. Stable isotope dilution assay (SIDA) and HS-SPME-GCMS quantification of key aroma volatiles for fruit and sap of Australian mango cultivars.

    PubMed

    San, Anh T; Joyce, Daryl C; Hofman, Peter J; Macnish, Andrew J; Webb, Richard I; Matovic, Nicolas J; Williams, Craig M; De Voss, James J; Wong, Siew H; Smyth, Heather E

    2017-04-15

    Reported herein is a high throughput method to quantify in a single analysis the key volatiles that contribute to the aroma of commercially significant mango cultivars grown in Australia. The method constitutes stable isotope dilution analysis (SIDA) in conjunction with headspace (HS) solid-phase microextraction (SPME) coupled with gas-chromatography mass spectrometry (GCMS). Deuterium labelled analogues of the target analytes were either purchased commercially or synthesised for use as internal standards. Seven volatiles, hexanal, 3-carene, α-terpinene, p-cymene, limonene, α-terpinolene and ethyl octanoate, were targeted. The resulting calibration functions had determination coefficients (R 2 ) ranging from 0.93775 to 0.99741. High recovery efficiencies for spiked mango samples were also achieved. The method was applied to identify the key aroma volatile compounds produced by 'Kensington Pride' and 'B74' mango fruit and by 'Honey Gold' mango sap. This method represents a marked improvement over current methods for detecting and measuring concentrations of mango fruit and sap volatiles. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in beer.

    PubMed

    Habler, Katharina; Gotthardt, Marina; Schüler, Jan; Rychlik, Michael

    2017-03-01

    A stable isotope dilution LC-MS/MS multi-mycotoxin method was developed for 12 different Fusarium toxins including modified mycotoxins in beer (deoxynivalenol-3-glucoside, deoxynivalenol, 3-acetyldeoxynivalenol, 15-acetyl-deoxynivalenol, HT2-toxin, T2-toxin, enniatin B, B1, A1, A, beauvericin and zearalenone). As sample preparation and purification of beer a combined solid phase extraction for trichothecenes, enniatins, beauvericin and zearalenone was firstly developed. The validation of the new method gave satisfying results: intra-day and inter-day precision and recoveries were 1-5%, 2-8% and 72-117%, respectively. In total, 61 different organic and conventional beer samples from Germany and all over the world were analyzed by using the newly developed multi-mycotoxin method. In summary, deoxynivalenol, deoxynivalenol-3-glucoside, 3-acetyldeoxynivaleneol and enniatin B were quantified in rather low contents in the investigated beer samples. None of the other monitored Fusarium toxins like 15-acetyldeoxynivalenol, HT2- and T2-toxin, zearalenone, enniatin B1, A1, A or beauvericin were detectable. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Regional water-quality analysis of 2,4-D and dicamba in river water using gas chromatography-isotope dilution mass spectrometry

    USGS Publications Warehouse

    Thurman, E.M.; Zimmerman, L.R.; Aga, D.S.; Gilliom, R.J.

    2001-01-01

    Gas chromatography with isotope dilution mass spectrometry (GC-MS) and enzyme-linked immunosorbent assay (ELISA) were used in regional National Water Quality Assessment studies of the herbicides, 2,4-D and dicamba, in river water across the United States. The GC-MS method involved solid-phase extraction, derivatized with deutemted 2,4-D, and analysis by selected ion monitoring. The ELISA method was applied after preconcentration with solid-phase extraction. The ELISA method was unreliable because of interference from humic substances that were also isolated by solid-phase extraction. Therefore, GC-MS was used to analyzed 80 samples from river water from 14 basins. The frequency of detection of dicamba (28%) was higher than that for 2,4-D (16%). Concentrations were higher for dicamba than for 2,4-D, ranging from less than the detection limit (<0.05 ??g/L) to 3.77 ??g/L, in spite of 5 times more annual use of 2,4-D as compared to dicamba. These results suggest that 2,4-D degrades more rapidly in the environment than dicamba.

  9. Development of two stable isotope dilution assays for the quantitation of acrolein in heat-processed fats.

    PubMed

    Ewert, Alice; Granvogl, Michael; Schieberle, Peter

    2011-04-27

    Two stable isotope dilution assays were developed for the quantitation of acrolein in fats and oils using [(13)C(3)]-acrolein as the internal standard. First, a direct GC-MS headspace method, followed by an indirect GC-MS method using derivatization with pentafluorophenyl hydrazine, was established. Analysis of six different types of oils varying in their pattern of fatty acids showed significant differences in the amounts of acrolein formed after heating at various temperatures and for various times. For example, after 24 h at 140 °C, coconut oil contained 6.7 mg/kg, whereas linseed oil was highest with 242.3 mg/kg. A comparison of the results showed that the extent of acrolein formation seemed to be correlated with the amount of linolenic acid in the oils. Although the acrolein concentrations were lowered in all six oils after frying of potato crisps, linseed and rapeseed oil still contained the highest amounts of acrolein after frying. By applying both methods on different thermally treated fats and oils, nearly identical quantitative data were obtained.

  10. Effects of conventional heating on the stability of major olive oil phenolic compounds by tandem mass spectrometry and isotope dilution assay.

    PubMed

    Attya, Mohamed; Benabdelkamel, Hicham; Perri, Enzo; Russo, Anna; Sindona, Giovanni

    2010-12-01

    The quality of olive oils is sensorially tested by accurate and well established methods. It enables the classification of the pressed oils into the classes of extra virgin oil, virgin oil and lampant oil. Nonetheless, it would be convenient to have analytical methods for screening oils or supporting sensorial analysis using a reliable independent approach based on exploitation of mass spectrometric methodologies. A number of methods have been proposed to evaluate deficiencies of extra virgin olive oils resulting from inappropriate technological treatments, such as high or low temperature deodoration, and home cooking processes. The quality and nutraceutical value of extra virgin olive oil (EVOO) can be related to the antioxidant property of its phenolic compounds. Olive oil is a source of at least 30 phenolic compounds, such as oleuropein, oleocanthal, hydroxytyrosol, and tyrosol, all acting as strong antioxidants, radical scavengers and NSAI-like drugs. We now report the efficacy of MRM tandem mass spectrometry, assisted by the isotope dilution assay, in the evaluation of the thermal stability of selected active principles of extra virgin olive oil.

  11. Application of the isotope-dilution principle to the analysis of factors affecting the incorporation of [3H]uridine and [3H]cytidine into cultured lymphocytes. Evaluation of pools in serum and culture media

    PubMed Central

    Forsdyke, D. R.

    1971-01-01

    1. Rat lymph-node cells were incubated in serum and medium 199 with [5-3H]uridine or [5-3H]cytidine and acid-precipitable radioactivity was measured. Results were interpreted in terms of an isotope-dilution model. 2. Both serum and medium 199 contained pools that inhibited radioactive labelling in a competitive manner. The serum activity was diffusible and inhibited labelling with [3H]cytidine more than with [3H]uridine; in these respects the activity resembled cytidine (14μm). 3. The pools in serum and plasma were the same size; however, the rate of labelling was greater in plasma, owing to a diffusible factor. 4. Paradoxically, relatively simple media (Earle's salts and Eagle's minimum essential) appeared to have a larger pool than the more complex pyrimidine-containing medium 199; this suggests a contribution to the pool by cells in the simple media. 5. In the absence of pools the average cell was capable of incorporating 2000 radioactive nucleoside molecules/s. PMID:4947658

  12. Quantification of Nε-(2-Furoylmethyl)-L-lysine (furosine), Nε-(Carboxymethyl)-L-lysine (CML), Nε-(Carboxyethyl)-L-lysine (CEL) and total lysine through stable isotope dilution assay and tandem mass spectrometry.

    PubMed

    Troise, Antonio Dario; Fiore, Alberto; Wiltafsky, Markus; Fogliano, Vincenzo

    2015-12-01

    The control of Maillard reaction (MR) is a key point to ensure processed foods quality. Due to the presence of a primary amino group on its side chain, lysine is particularly prone to chemical modifications with the formation of Amadori products (AP), Nε-(Carboxymethyl)-L-lysine (CML), Nε-(Carboxyethyl)-L-lysine (CEL). A new analytical strategy was proposed which allowed to simultaneously quantify lysine, CML, CEL and the Nε-(2-Furoylmethyl)-L-lysine (furosine), the indirect marker of AP. The procedure is based on stable isotope dilution assay followed by liquid chromatography tandem mass spectrometry. It showed high sensitivity and good reproducibility and repeatability in different foods. The limit of detection and the RSD% were lower than 5 ppb and below 8%, respectively. Results obtained with the new procedure not only improved the knowledge about the reliability of thermal treatment markers, but also defined new insights in the relationship between Maillard reaction products and their precursors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Nicotine demethylation in Nicotiana cell suspension cultures: N'-formylnornicotine is not involved.

    PubMed

    Bartholomeusz, Trixie Ann; Bhogal, Ramneek K; Molinié, Roland; Felpin, François-Xavier; Mathé-Allainmat, Monique; Meier, Anna-Carolin; Dräger, Birgit; Lebreton, Jacques; Roscher, Albrecht; Robins, Richard J; Mesnard, François

    2005-10-01

    Nicotine or nornicotine enriched with stable isotopes in either the N'-methyl group or the pyrrolidine-N were fed to Nicotiana plumbaginifolia suspension cell cultures that do not form endogenous nicotine. The metabolism of these compounds was investigated by analysing the incorporation of isotope into other alkaloids using gas chromatography-mass spectroscopy (GC-MS). Nicotine metabolism primarily resulted in the accumulation of nornicotine, the N'-demethylation product. In addition, six minor metabolites appeared during the course of nicotine metabolism, four of which were identified as cotinine, myosmine, N'-formylnornicotine and N'-carboethoxynornicotine. While cotinine was formed from [(13)C,(2)H(3)-methyl]nicotine without dilution of label, N'-formylnornicotine was labelled at only about 6% of the level of nicotine and N'-carboethoxynornicotine was unlabelled. Feeding with [1'-(15)N]nornicotine resulted in incorporation without dilution of label into both N'-formylnornicotine and N'-carboethoxynornicotine. This pattern strongly indicates that, while nornicotine and cotinine are derived directly from nicotine, N'-formylnornicotine and N'-carboethoxynornicotine are metabolites of nornicotine. Thus, it is directly demonstrated that N'-formylnornicotine is not an intermediate in nicotine demethylation.

  14. Quantification of Labile Soil Mercury by Stable Isotope Dilution Techniques

    NASA Astrophysics Data System (ADS)

    Shetaya, Waleed; Huang, Jen-How; Osterwalder, Stefan; Alewell, Christine

    2016-04-01

    Mercury (Hg) is a toxic element that can cause severe health problems to humans. Mercury is emitted to the atmosphere from both natural and anthropogenic sources and can be transported over long distances before it is deposited to aquatic and terrestrial environments. Aside from accumulation in soil solid phases, Hg deposited in soils may migrate to surface- and ground-water or enter the food chain, depending on its lability. There are many operationally-defined extraction methods proposed to quantify soil labile metals. However, these methods are by definition prone to inaccuracies such as non-selectivity, underestimation or overestimation of the labile metal pool. The isotopic dilution technique (ID) is currently the most promising method for discrimination between labile and non-labile metal fractions in soil with a minimum disturbance to soil-solid phases. ID assesses the reactive metal pool in soil by defining the fraction of metal both in solid and solution phases that is isotopically-exchangeable known as the 'E-value'. The 'E-value' represents the metal fraction in a dynamic equilibrium with the solution phase and is potentially accessible to plants. This is carried out by addition of an enriched metal isotope to soil suspensions and quantifying the fraction of metal that is able to freely exchange with the added isotope by measuring the equilibrium isotopic ratio by ICP-MS. E-value (mg kg-1) is then calculated as follows: E-Value = (Msoil/ W) (CspikeVspike/ Mspike) (Iso1IAspike -Iso2IAspikeRss / Iso2IAsoil Rss - Iso1IAsoil) where M is the average atomic mass of the metal in the soil or the spike, W is the mass of soil (kg), Cspike is the concentration of the metal in the spike (mg L-1), Vspike is the volume of spike (L), IA is isotopic abundance, and Rss is the equilibrium ratio of isotopic abundances (Iso1:Iso2). Isotopic dilution has been successfully applied to determine E-values for several elements. However, to our knowledge, this method has not yet been applied to estimate the labile pool of mercury in contaminated soils. We performed a series of soil incubations spiked with 196Hg2+aiming at measuring and modelling the progressive assimilation of Hg ions into less labile forms. Soils with a wide range of characteristics are taken for our research purpose, inclusive of Hg concentrations ranging from 0.1 to 390 mg kg-1, pH between 3.5 - 7.5 and total organic carbon (TOC) between 2.5 - 8 %. In parallel, the labile pool of Hg estimated using ID will be compared with that determined using conventional extraction methods, e.g. sequential extraction procedures. These altogether allows us to answer (1) how the E-value of Hg in soils is comparable to those estimated based on selective extraction methods, (2) how the labile Hg correlates with the total soil Hg, soil pH and TOC, and (3) how the solubility of added Hg (e.g. via rainfall) decreased in soils of different properties during aging. The obtained results fills the knowledge gap concerning Hg biogeochemistry in the terrestrial environment and serves as a basis for estimating (and predicting) the risk of soil Hg diffusion from a point source to the adjacent environments.

  15. Development of a thermodynamic model for a cold cycle 3He-4He dilution refrigerator

    NASA Astrophysics Data System (ADS)

    Mueller, B. W.; Miller, F. K.

    2016-10-01

    A thermodynamic model of a 3He-4He cold cycle dilution refrigerator with no actively-driven mechanical components is developed and investigated. The refrigerator employs a reversible superfluid magnetic pump, passive check valves, a phase separation chamber, and a series of recuperative heat exchangers to continuously circulate 3He-4He and maintain a 3He concentration gradient across the mixing chamber. The model predicts cooling power and mixing chamber temperature for a range of design and operating parameters, allowing an evaluation of feasibility for potential 3He-4He cold cycle dilution refrigerator prototype designs. Model simulations for a prototype refrigerator design are presented.

  16. Reverse weathering in marine sediments and the geochemical cycle of potassium in seawater: Insights from the K isotopic composition (41K/39K) of deep-sea pore-fluids

    USGS Publications Warehouse

    Santiago Ramos, Danielle P.; Morgan, Leah; Lloyd, Nicholas S.; Higgins, John A.

    2018-01-01

    In situ Al-silicate formation, also known as “reverse weathering,” is an important sink of many of the major and minor cations in seawater (e.g. Mg, K, and Li). However, the importance of this sink in global geochemical cycles and isotopic budgets of these elements remains poorly constrained. Here, we report on the potassium isotopic composition (41">41K/39">39K) of deep-sea sediment pore-fluids from four (Integrated) Ocean Drilling Program sites (1052, U1378, U1395 and U1403) to characterize potassium isotopic fractionation associated with the formation of authigenic Al-silicate minerals in marine sediments and its role in elevating the 41">41K/39">39K of seawater relative to bulk silicate Earth. Isotopic ratios are obtained by high-resolution multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) in cold plasma conditions with a long-term external reproducibility of ca. 0.17‰. We find that, although all sites are characterized by pore-fluid K concentrations that decline with increasing depth, their K isotopic profiles vary systematically from site-to-site; at sites characterized by rapid sedimentation rates, pore-fluid profiles of 41">41K/39">39K are relatively invariant whereas at sites characterized by slow sedimentation rates, 41">41K/39">39K declines with depth by up to 1.8‰. Results from 1-D diffusion-advection-reaction models suggest that these differences may result from a complex interplay between sedimentation rate and fractionation of K isotopes during diffusion, Al-silicate authigenesis, and ion exchange. Model simulations suggest fractionation factors between 0.9980 and 1.0000 for reverse weathering reactions in deep-sea sediments. Although deep-sea sites do not constitute major sinks of K in seawater, some of the processes responsible for K isotopic fractionation at these sites (diffusion and Al-silicate authigenesis) likely play a role in determining the 41">41K/39">39K of seawater.

  17. Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results

    PubMed Central

    Tonyushkina, Ksenia; Nichols, James H.

    2009-01-01

    Glucose meters are universally utilized in the management of hypoglycemic and hyperglycemic disorders in a variety of healthcare settings. Establishing the accuracy of glucose meters, however, is challenging. Glucose meters can only analyze whole blood, and glucose is unstable in whole blood. Technical accuracy is defined as the closeness of agreement between a test result and the true value of that analyte. Truth for glucose is analysis by isotope dilution mass spectrometry, and frozen serum standards analyzed by this method are available from the National Institute of Standards and Technology. Truth for whole blood has not been established, and cells must be separated from the whole blood matrix before analysis by a method like isotope dilution mass spectrometry. Serum cannot be analyzed by glucose meters, and isotope dilution mass spectrometry is not commonly available in most hospitals and diabetes clinics to evaluate glucose meter accuracy. Consensus standards recommend comparing whole blood analysis on a glucose meter against plasma/serum centrifuged from a capillary specimen and analyzed by a clinical laboratory comparative method. Yet capillary samples may not provide sufficient volume to test by both methods, and venous samples may be used as an alternative when differences between venous and capillary blood are considered. There are thus multiple complexities involved in defining technical accuracy and no clear consensus among standards agencies and professional societies on accuracy criteria. Clinicians, however, are more concerned with clinical agreement of the glucose meter with a serum/plasma laboratory result. Acceptance criteria for clinical agreement vary across the range of glucose concentrations and depend on how the result will be used in screening or management of the patient. A variety of factors can affect glucose meter results, including operator technique, environmental exposure, and patient factors, such as medication, oxygen therapy, anemia, hypotension, and other disease states. This article reviews the challenges involved in obtaining accurate glucose meter results. PMID:20144348

  18. Simultaneous quantification of GM1 and GM2 gangliosides by isotope dilution tandem mass spectrometry.

    PubMed

    Gu, Jianghong; Tifft, Cynthia J; Soldin, Steven J

    2008-04-01

    Gangliosides (GGs) are considered as diagnostic biomarkers and therapeutic targets and agents. The goal of this study was to develop a tandem mass spectrometry (MS/MS) method for the simultaneous measurement of both GM1 and GM2 gangliosides in human cerebrospinal fluid (CSF) samples in order to be able to determine their concentrations in patients with Tay-Sachs and Sandhoff disease and assess whether drugs or transplantation affect their concentrations. An API-4000 tandem mass spectrometer equipped with TurboIonSpray source and Shimadzu HPLC system was employed to perform the analysis using isotope dilution with deuterium labeled internal standards. To a 1.5 mL conical plastic Eppendorf centrifuge tube, 40 microL of human CSF sample was added and mixed with 400 microL of internal standard solution for deproteinization. After centrifugation, 100 microL of supernatant was injected onto a C-18 column. After a 2.5 min wash, the switching valve was activated and the analytes were eluted from the column with a water/methanol gradient into the MS/MS system. Quantification by multiple reaction-monitoring (MRM) analysis was performed in the negative mode. The within-day coefficients of variation were <3% for GM1 and <2% for GM2 and the between-day coefficients of variation were <5% for both GM1 and GM2 at all concentrations tested. Accuracy ranged between 98% and 102% for both analytes. Good linearity was also obtained within the concentration range of 10-200 ng/mL (6.5-129.3 nmol/L) for GM1 and 5-100 ng/mL (3.6-72.3 nmol/L) for GM2 (r> or =0.995). A new simple, accurate, and fast isotope dilution tandem mass spectrometry method was developed for the simultaneous quantification of GM1 and GM2 gangliosides in a small amount of human CSF. Concentrations were measured in "normal" CSF and in CSF from patients with Tay-Sachs disease.

  19. Analysis of nitrosamines in water by automated SPE and isotope dilution GC/HRMS Occurrence in the different steps of a drinking water treatment plant, and in chlorinated samples from a reservoir and a sewage treatment plant effluent.

    PubMed

    Planas, Carles; Palacios, Oscar; Ventura, Francesc; Rivera, Josep; Caixach, Josep

    2008-08-15

    A method based on automated solid-phase extraction (SPE) and isotope dilution gas chromatography/high resolution mass spectrometry (GC/HRMS) has been developed for the analysis of nine nitrosamines in water samples. The combination of automated SPE and GC/HRMS for the analysis of nitrosamines has not been reported previously. The method shows as advantages the selectivity and sensitivity of GC/HRMS analysis and the high efficiency of automated SPE with coconut charcoal EPA 521 cartridges. Low method detection limits (MDLs) were achieved, along with a greater facility of the procedure and less dependence on the operator with regard to the methods based on manual SPE. Quality requirements for isotope dilution-based methods were accomplished for most analysed nitrosamines, regarding to trueness (80-120%), method precision (<15%) and MDLs (0.08-1.7 ng/L). Nineteen water samples (16 samples from a drinking water treatment plant {DWTP}, 2 chlorinated samples from a sewage treatment plant {STP} effluent, and 1 chlorinated sample from a reservoir) were analysed. Concentrations of nitrosamines in the STP effluent were 309.4 and 730.2 ng/L, being higher when higher doses of chlorine were applied. N-Nitrosodimethylamine (NDMA) and N-nitrosodiethylamine (NDEA) were the main compounds identified in the STP effluent, and NDEA was detected above 200 ng/L, regulatory level for NDMA in effluents stated in Ontario (Canada). Lower concentrations of nitrosamines were found in the reservoir (20.3 ng/L) and in the DWTP samples (n.d. -28.6 ng/L). NDMA and NDEA were respectively found in the reservoir and in treated and highly chlorinated DWTP samples at concentrations above 10 ng/L (guide value established in different countries). The highest concentrations of nitrosamines were found after chlorination and ozonation processes (ozonated, treated and highly chlorinated water) in DWTP samples.

  20. An isotope-dilution UPLC-MS/MS technique for the human biomonitoring of the internal exposure to glycidol via a valine adduct at the N-terminus of hemoglobin.

    PubMed

    Hielscher, Jan; Monien, Bernhard H; Abraham, Klaus; Jessel, Sönke; Seidel, Albrecht; Lampen, Alfonso

    2017-08-01

    Fatty acid esters of glycidol (glycidyl esters) are processing contaminants generated as a byproduct of the industrial deodorization of vegetable oils and fats. Oral intake of glycidyl esters leads to the release of glycidol in the gastrointestinal tract. Glycidol is carcinogenic, genotoxic and teratogenic in rodents. It is rated as probably carcinogenic to humans (IARC group 2A). The determination of internal exposure of glycidol may support the assessment of the possible human health risks related to glycidyl ester intake. For this purpose, hemoglobin adducts of glycidol may be suitable biomarkers reflecting the cumulative exposure of up to four months. We applied a modified Edman degradation to assess the glycidol adduct at the N-terminal valine, N-(2,3-dihydroxypropyl)-valine (2,3-diHOPr-Val), of hemoglobin. The modified valine was cleaved with fluorescein-5-isothiocyanate (FITC), resulting in the formation of N-(2,3-dihydroxypropyl)-valine fluorescein thiohydantoin (DHP-Val-FTH). An isotope-dilution technique was developed for the quantification of the thiohydantoin analyte by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) and DHP-Val-d 7 -FTH as reference standard. The limit of detection was 4 fmol DHP-Val-FTH per injection corresponding to 0.7pmol 2,3-diHOPr-Val/g hemoglobin. The adduct levels in blood samples of 12 non-smoking participants were in the range of 2.2-4.9pmol 2,3-diHOPr-Val/g hemoglobin. The current work presents the first isotope-dilution technique using UPLC-MS/MS for the quantification of 2,3-diHOPr-Val at the N-terminus of hemoglobin as a sensitive and convenient alternative to earlier GC-MS methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Determination of 90Sr / 238U ratio by double isotope dilution inductively coupled plasma mass spectrometer with multiple collection in spent nuclear fuel samples with in situ 90Sr / 90Zr separation in a collision-reaction cell

    NASA Astrophysics Data System (ADS)

    Isnard, H.; Aubert, M.; Blanchet, P.; Brennetot, R.; Chartier, F.; Geertsen, V.; Manuguerra, F.

    2006-02-01

    Strontium-90 is one of the most important fission products generated in nuclear industry. In the research field concerning nuclear waste disposal in deep geological environment, it is necessary to quantify accurately and precisely its concentration (or the 90Sr / 238U atomic ratio) in irradiated fuels. To obtain accurate analysis of radioactive 90Sr, mass spectrometry associated with isotope dilution is the most appropriated method. But, in nuclear fuel samples the interference with 90Zr must be previously eliminated. An inductively coupled plasma mass spectrometer with multiple collection, equipped with an hexapole collision cell, has been used to eliminate the 90Sr / 90Zr interference by addition of oxygen in the collision cell as a reactant gas. Zr + ions are converted into ZrO +, whereas Sr + ions are not reactive. A mixed solution, prepared from a solution of enriched 84Sr and a solution of enriched 235U was then used to quantify the 90Sr / 238U ratio in spent fuel sample solutions using the double isotope dilution method. This paper shows the results, the reproducibility and the uncertainties that can be obtained with this method to quantify the 90Sr / 238U atomic ratio in an UOX (uranium oxide) and a MOX (mixed oxide) spent fuel samples using the collision cell of an inductively coupled plasma mass spectrometer with multiple collection to perform the 90Sr / 90Zr separation. A comparison with the results obtained by inductively coupled plasma mass spectrometer with multiple collection after a chemical separation of strontium from zirconium using a Sr spec resin (Eichrom) has been performed. Finally, to validate the analytical procedure developed, measurements of the same samples have been performed by thermal ionization mass spectrometry, used as an independent technique, after chemical separation of Sr.

  2. Key Aroma Compounds in Smoked Cooked Loin.

    PubMed

    Kosowska, Monika; Majcher, Małgorzata A; Jeleń, Henryk H; Fortuna, Teresa

    2018-04-11

    Smoked cooked loin is one of the most popular meat products in Poland. In this study, key volatile compounds in this traditional Polish meat product were determined using gas chromatography-olfactometry and aroma extract dilution analysis (AEDA). In total, 27 odor-active volatile compounds were identified, with flavor dilution (FD) factors ranging from 4 to 1024, with the highest FD factors noted for 2-methoxyphenol, 2-methoxy-4-(prop-2-enyl)phenol, and 2-methoxy-4-( E)-(prop-1-en-1-yl)phenol. Results of the quantitative analyses based on determinations with stable isotope dilution assays (SIDAs) and standard addition (SA), followed by calculations of the odor activity value (OAV), enabled identifying 24 of the volatile compounds responsible for flavor development in the analyzed smoked cooked loin. The highest OAVs were obtained for 2-methoxyphenol, 2-methyl-3-furanthiol, 1-octen-3-one, and 2-methyl-3-(methyldithio)furan.

  3. Identification and Quantitation of Potent Odorants in Spearmint Oils.

    PubMed

    Kelley, Lauren E; Cadwallader, Keith R

    2018-03-14

    Potent odorants in Native spearmint, Scotch spearmint, and Macho mint oils were determined by the combined use of gas chromatography-olfactometry (GCO), gas chromatography-mass spectrometry (GC-MS), and aroma extract dilution analysis (AEDA). Of the 85 odorants detected, ( R)-(-)-carvone was the most potent odorant in all three spearmint oils. Additional predominant odorants in all spearmint oils included eugenol, ethyl ( S)-(+)-2-methylbutanoate, ( E)-β-damascenone, and (3 E,5 Z)-1,3,5-undecatriene. Forty-six compounds were quantitated using various methods, including 19 by gas chromatography with flame ionization detection (GC-FID), 20 by stable isotope dilution analysis (SIDA), and 14 by GCO dilution analysis. Concentrations were used to calculate the odor activity values (OAVs) for predominant odorants in the oils. Among the compounds quantitated, those with the highest OAVs were ( R)-(-)-carvone, 1,8-cineole, ( E, Z)-2,6-nonadienal, ( E)-β-damascenone, and (3 E,5 Z)-1,3,5-undecatriene.

  4. Mercury dilution by autochthonous organic matter in a fertilized mangrove wetland.

    PubMed

    Machado, Wilson; Sanders, Christian J; Santos, Isaac R; Sanders, Luciana M; Silva-Filho, Emmanoel V; Luiz-Silva, Wanilson

    2016-06-01

    A dated sediment core from a highly-fertilized mangrove wetland located in Cubatão (SE Brazil) presented a negative correlation between mercury (Hg) and organic carbon contents. This is an unusual result for a metal with well-known affinity to organic matter. A dilution of Hg concentrations by autochthonous organic matter explained this observation, as revealed by carbon stable isotopes signatures (δ(13)C). Mercury dilution by the predominant mangrove-derived organic matter counterbalanced the positive influences of algal-derived organic matter and clay contents on Hg levels, suggesting that deleterious effects of Hg may be attenuated. Considering the current paradigm on the positive effect of organic matter on Hg concentrations in coastal sediments and the expected increase in mangrove organic matter burial due to natural and anthropogenic stimulations of primary production, predictions on the influences of organic matter on Hg accumulation in mangrove wetlands deserve caution. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Gas chromatography/isotope ratio mass spectrometry: analysis of methanol, ethanol and acetic acid by direct injection of aqueous alcoholic and acetic acid samples.

    PubMed

    Ai, Guomin; Sun, Tong; Dong, Xiuzhu

    2014-08-15

    Methanol, ethanol, and acetic acid are not easily extracted from aqueous samples and are susceptible to isotope fractionation in gas chromatography/isotope ratio mass spectrometry (GC/IRMS) analysis. Developing a direct dilution GC/IRMS method for aqueous samples, by adjusting the sample concentrations in common solvents to be similar to each other and using a fixed GC split ratio, is very convenient and important because any linearity effects caused by amount-dependent isotope fractionation can be avoided. The suitability of acetonitrile and acetone solvents for the GC/IRMS analysis of pure methanol, ethanol and acetic acid, and commercial liquor and vinegar samples was evaluated using n-hexane and water as control solvents. All the solvents including water were separated from the analyte on a HP-INNOWAX column and were diverted away from the combustion interface. The influence of liquor matrix on the ethanol GC/IRMS analyses was evaluated by adding pure ethanol to liquor samples. Acetonitrile and acetone gave similar δ(13) C values for pure ethanol and pure acetic acid to those obtained in water and n-hexane, and also gave similar δ(13) C values of ethanol in liquor and acetic acid in white vinegar to that obtained in water. For methanol analysis, acetonitrile and refined acetone gave similar δ(13) C values to that obtained in water, but n-hexane was not a suitable solvent. In addition, isotopic fractionation caused by solvent and solute interactions was observed. We recommend using acetonitrile for the GC/IRMS analysis of aqueous alcoholic samples, and acetone for the analysis of aqueous acetic acid samples. This direct dilution method can provide high accurate and precise GC/IRMS analysis of the relative changes in δ(13) C values of methanol, ethanol, and acetic acid. Copyright © 2014 John Wiley & Sons, Ltd.

  6. Creation of a predictive equation to estimate fat-free mass and the ratio of fat-free mass to skeletal size using morphometry in lean working farm dogs.

    PubMed

    Leung, Y M; Cave, N J; Hodgson, B A S

    2018-06-27

    To develop an equation that accurately estimates fat-free mass (FFM) and the ratio of FFM to skeletal size or mass, using morphometric measurements in lean working farm dogs, and to examine the association between FFM derived from body condition score (BCS) and FFM measured using isotope dilution. Thirteen Huntaway and seven Heading working dogs from sheep and beef farms in the Waikato region of New Zealand were recruited based on BCS (BCS <3, 3-4, >4) using a nine-point scale. Bodyweight, BCS, and morphometric measurements (head length and circumference, body length, thoracic girth, and fore and hind limb length) were recorded for each dog, and body composition was measured using an isotopic dilution technique. A new variable using morphometric measurements, termed skeletal size, was created using principal component analysis. Models for predicting FFM, leanST (FFM minus skeletal mass) and ratios of FFM and leanST to skeletal size or mass were generated using multiple linear regression analysis. Mean FFM of the 20 dogs, measured by isotope dilution, was 22.1 (SD 4.4) kg and the percentage FFM of bodyweight was 87.0 (SD 5.0)%. Median BCS was 3.0 (min 1, max 6). Bodyweight, breed, age and skeletal size or mass were associated with measured FFM (p<0.001). There was a good correlation between predicted FFM and measured FFM (R 2 =0.96), and for the ratio of predicted FFM to skeletal size and measured values (R 2 =0.99). Correlation coefficients were higher for the ratio FFM and leanST to skeletal size than for ratios using skeletal mass. There was a positive correlation between BCS-derived fat mass as a percentage of bodyweight and fat mass percentage determined using isotope dilution (R 2 =0.65). As expected, the predictive equation was accurate in estimating FFM when tested on the same group of dogs used to develop the equation. The significance of breed, independent of skeletal size, in predicting FFM indicates that individual breed formulae may be required. Future studies that apply these equations on a greater population of working Huntaway and Heading dogs are needed to establish the utility of these equations on a large scale. Such studies could ascertain if there is a ratio for lean mass to skeletal size below which the risk of injury or disease increases. If these equations prove useful they would provide an objective and non-invasive measure to determine when welfare in individual dogs is compromised by underfeeding.

  7. Determination of the relative uptake of ground vs. surface water by Populus deltoides during phytoremediation

    USGS Publications Warehouse

    Clinton, B.D.; Vose, J.M.; Vroblesky, D.A.; Harvey, G.J.

    2004-01-01

    The use of plants to remediate polluted groundwater is becoming an attractive alternative to more expensive traditional techniques. In order to adequately assess the effectiveness of the phytoremediation treatment, a clear understanding of water-use habits by the selected plant species is essential. We examined the relative uptake of surface water (i.e., precipitation) vs. groundwater by mature Populus deltoides by applying irrigation water at a rate equivalent to a 5-cm rain event. We used stable isotopes of hydrogen (D) and oxygen (18O) to identify groundwater and surface water (irrigation water) in the xylem sap water. Pretreatment isotopic ratios of both deuterium and 18O, ranked from heaviest to lightest, were irrigation water > groundwater > xylem sap. The discrepancy in preirrigation isotopic signatures between groundwater and xylem sap suggests that in the absence of a surface source of water (i.e., between rain events) there is an unknown amount of water being extracted from sources other than groundwater (i.e., soil surface water). We examined changes in volumetric soil water content (%), total hourly sapflux rates, and trichloroethene (TCE) concentrations. Following the irrigation treatment, volumetric soil water increased by 86% and sapflux increased by as much as 61%. Isotopic signatures of the xylem sap became substantially heavier following irrigation, suggesting that the applied irrigation water was quickly taken up by the plants. TCE concentrations in the xylem sap were diluted by an average of 21% following irrigation; however, dilution was low relative to the increase in sapflux. Our results show that water use by Populus deltoides is variable. Hence, studies addressing phytoremediation effectiveness must account for the relative proportion of surface vs. groundwater uptake.

  8. Determination of low-level (sub-microgram) sulfur concentrations by isotope dilution multi-collector inductively couple plasma mass spectrometry using a 33S spike and internal normalization for mass bias correction.

    PubMed

    Mann, Jacqueline L; Vocke, Robert D; Kelly, W Robert

    2012-05-30

    The certification of sulfur (S) in Standard Reference Materials™ by the National Institute of Standards and Technology (NIST) has been exclusively performed using isotope dilution thermal ionization mass spectrometry (ID-TIMS). The ID-TIMS measurement method is limited in its capability for low concentration measurements (<1 µg/g) due to the blank associated with the chemical reduction procedure (≈0.2 S µg). Newly developed materials and applications, such as biofuels made from soy and nanomedicine, pose a challenge to the ID-TIMS technique because of their very low concentrations (<1 µg/g) of S. As described here, a measurement technique with low S blanks is essential for low-level S measurements. An isotope dilution (ID) multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) method combined with an internal normalization approach for mass bias correction has been used to determine low-level S concentrations in synthetically prepared mixtures using a (33)S-enriched spike material. Dilute sulfur solutions (1 µg S/g) were prepared from NIST SRM 3154 (Sulfate Spectrometric Solution) to test the capability of this technique for measuring very low-level S concentrations. The concentration results for each solution were 0.983 ± 0.004 µg/g (95% CI, n = 2, k = 2), 1.006 ± 0.005 µg/g (95% CI, n = 2, k = 2), and 0.999 ± 0.003 µg/g (95% CI, n = 2, k = 2), in excellent agreement with the gravimetric determination, deviating less than 0.35% and suggesting the technique can yield unbiased and accurate results. The blanks averaged 13 ± 0.0017 ng S (1s). The data results provide a clear indication that the ID-MC-ICP-MS method for the determination of low-level S concentrations is feasible. The more than one order of magnitude reduction of the blanks suggests that it is a better alternative to the ID-TIMS method for very low S materials such as are encountered in biofuels and some biochemical species. Published 2012. This article is a US Government work and is in the public domain in the USA. Published 2012. This article is a US Government work and is in the public domain in the USA.

  9. Drinking behaviour and water turnover rates of Antarctic fur seal pups: implications for the estimation of milk intake by isotopic dilution.

    PubMed

    Lea, Mary-Anne; Bonadonna, Francesco; Hindell, Mark A; Guinet, Christophe; Goldsworthy, Simon D

    2002-06-01

    The estimation of milk consumption in free-ranging seals using tritium dilution techniques makes the key assumption that the animals drink no pre-formed water during the experimental period. However, frequent observations of unweaned Antarctic fur seal pups drinking water at Iles Kerguelen necessitated the testing of this assumption. We estimated water flux rates of 30 pups (10.7+/-0.3 kg) in four experimental groups by isotopic dilution over 4 days. The groups were: (1) pups held in an open air enclosure without access to water to estimate fasting metabolic water production (MWP); (2) free-ranging pups not administered additional water; (3) pups held in an open air enclosure and given a total of 300 ml of fresh water to verify technique accuracy; and (4) free-ranging pups given 200 ml of fresh water. Pups without access to water exhibited water flux rates (20.5+/-0.8 ml kg(-1)d(-1)), which were significantly lower than those observed for the free-ranging group (33.0+/-1.7 ml kg(-1) d(-1)). Mean estimated pre-formed water intake for the free-ranging experimental groups was 12.6 ml kg(-1) d(-1). Thus, MWP, measured as total water intake during fasting, may be significantly over-estimated in free-ranging Antarctic fur seal pups at Iles Kerguelen and at other sites and subsequently milk intake rates may be underestimated.

  10. Protein quantification using a cleavable reporter peptide.

    PubMed

    Duriez, Elodie; Trevisiol, Stephane; Domon, Bruno

    2015-02-06

    Peptide and protein quantification based on isotope dilution and mass spectrometry analysis are widely employed for the measurement of biomarkers and in system biology applications. The accuracy and reliability of such quantitative assays depend on the quality of the stable-isotope labeled standards. Although the quantification using stable-isotope labeled peptides is precise, the accuracy of the results can be severely biased by the purity of the internal standards, their stability and formulation, and the determination of their concentration. Here we describe a rapid and cost-efficient method to recalibrate stable isotope labeled peptides in a single LC-MS analysis. The method is based on the equimolar release of a protein reference peptide (used as surrogate for the protein of interest) and a universal reporter peptide during the trypsinization of a concatenated polypeptide standard. The quality and accuracy of data generated with such concatenated polypeptide standards are highlighted by the quantification of two clinically important proteins in urine samples and compared with results obtained with conventional stable isotope labeled reference peptides. Furthermore, the application of the UCRP standards in complex samples is described.

  11. Triple-Label β Liquid Scintillation Counting

    PubMed Central

    Bukowski, Thomas R.; Moffett, Tyler C.; Revkin, James H.; Ploger, James D.; Bassingthwaighte, James B.

    2010-01-01

    The detection of radioactive compounds by liquid scintillation has revolutionized modern biology, yet few investigators make full use of the power of this technique. Even though multiple isotope counting is considerably more difficult than single isotope counting, many experimental designs would benefit from using more than one isotope. The development of accurate isotope counting techniques enabling the simultaneous use of three β-emitting tracers has facilitated studies in our laboratory using the multiple tracer indicator dilution technique for assessing rates of transmembrane transport and cellular metabolism. The details of sample preparation, and of stabilizing the liquid scintillation spectra of the tracers, are critical to obtaining good accuracy. Reproducibility is enhanced by obtaining detailed efficiency/quench curves for each particular set of tracers and solvent media. The numerical methods for multiple-isotope quantitation depend on avoiding error propagation (inherent to successive subtraction techniques) by using matrix inversion. Experimental data obtained from triple-label β counting illustrate reproducibility and good accuracy even when the relative amounts of different tracers in samples of protein/electrolyte solutions, plasma, and blood are changed. PMID:1514684

  12. Natural isotope correction of MS/MS measurements for metabolomics and (13)C fluxomics.

    PubMed

    Niedenführ, Sebastian; ten Pierick, Angela; van Dam, Patricia T N; Suarez-Mendez, Camilo A; Nöh, Katharina; Wahl, S Aljoscha

    2016-05-01

    Fluxomics and metabolomics are crucial tools for metabolic engineering and biomedical analysis to determine the in vivo cellular state. Especially, the application of (13)C isotopes allows comprehensive insights into the functional operation of cellular metabolism. Compared to single MS, tandem mass spectrometry (MS/MS) provides more detailed and accurate measurements of the metabolite enrichment patterns (tandem mass isotopomers), increasing the accuracy of metabolite concentration measurements and metabolic flux estimation. MS-type data from isotope labeling experiments is biased by naturally occurring stable isotopes (C, H, N, O, etc.). In particular, GC-MS(/MS) requires derivatization for the usually non-volatile intracellular metabolites introducing additional natural isotopes leading to measurements that do not directly represent the carbon labeling distribution. To make full use of LC- and GC-MS/MS mass isotopomer measurements, the influence of natural isotopes has to be eliminated (corrected). Our correction approach is analyzed for the two most common applications; (13)C fluxomics and isotope dilution mass spectrometry (IDMS) based metabolomics. Natural isotopes can have an impact on the calculated flux distribution which strongly depends on the substrate labeling and the actual flux distribution. Second, we show that in IDMS based metabolomics natural isotopes lead to underestimated concentrations that can and should be corrected with a nonlinear calibration. Our simulations indicate that the correction for natural abundance in isotope based fluxomics and quantitative metabolomics is essential for correct data interpretation. © 2015 Wiley Periodicals, Inc.

  13. Atomic substitutions in synthetic apatite; Insights from solid-state NMR spectroscopy

    NASA Astrophysics Data System (ADS)

    Vaughn, John S.

    Apatite, Ca5(PO4)3X (where X = F, Cl, or OH), is a unique mineral group capable of atomic substitutions for cations and anions of varied size and charge. Accommodation of differing substituents requires some kind of structural adaptation, e.g. new atomic positions, vacancies, or coupled substitutions. These structural adaptations often give rise to important physicochemical properties relevant to a range of scientific disciplines. Examples include volatile trapping during apatite crystallization, substitution for large radionuclides for long-term storage of nuclear fission waste, substitution for fluoride to improve acid resistivity in dental enamel composed dominantly of hydroxylapatite, and the development of novel biomaterials with enhanced biocompatibility. Despite the importance and ubiquity of atomic substitutions in apatite materials, many of the mechanisms by which these reactions occur are poorly understood. Presence of substituents at dilute concentration and occupancy of disordered atomic positions hinder detection by bulk characterization methods such as X-ray diffraction (XRD) and infrared (IR) spectroscopy. Solid-state nuclear magnetic resonance (NMR) spectroscopy is an isotope-specific structural characterization technique that does not require ordered atomic arrangements, and is therefore well suited to investigate atomic substitutions and structural adaptations in apatite. In the present work, solid-state NMR is utilized to investigate structural adaptations in three different types of apatite materials; a series of near-binary F, Cl apatite, carbonate-hydroxylapatite compositions prepared under various synthesis conditions, and a heat-treated hydroxylapatite enriched in 17O. The results indicate that hydroxyl groups in low-H, near binary F,Cl apatite facilitate solid-solution between F and Cl via column reversals, which result in average hexagonal symmetry despite very dilute OH concentration ( 2 mol percent). In addition, 19F NMR spectra indicate that fluorine occupies a complex distribution of atomic positions, which give rise to complex 19F peak shapes owing to varied F-Ca distance. 13C NMR analysis of carbonate-hydroxylapatite indicates that AB-type carbonate hydroxylapatite can be prepared without the presence of sodium or heat treatment. Isotopic 17O enrichment of hydroxylapatite and 17O NMR analysis reveals distinct signals corresponding to phosphate and hydroxyl oxygens, and heat treatment under vacuum results in loss of hydroxyl signal due to decomposition to tricalcium phosphate, which was observed by powder X-Ray diffraction (PXRD).

  14. Sex Reversal and Analyses of Possible Involvement of Sex Steroids in Scallop Gonadal Development in Newly Established Organ-Culture Systems.

    PubMed

    Otani, Ayano; Nakajima, Tadaaki; Okumura, Tomomi; Fujii, Shiro; Tomooka, Yasuhiro

    2017-04-01

    Many molluscs perform sex reversal, and sex hormones may be involved in the process. In adult scallops, Patinopecten yessoensis, gonadotropin releasing hormone and 17β-estradiol (E 2 ) are involved in male sexual maturation, however, little is known about the effects of E 2 and testosterone (T) on the gonadal differentiation in young scallops. In the present study, scallop gonadal development was analyzed to determine the sex reversal stage in Funka bay, and effects of E 2 and T were examined. In Funka bay, almost all scallops were male at month 12. Scallops equipped with ambiguous gonads were 61.1% at month 16 and disappeared at month 18. Therefore, sex reversal in Funka bay occurs at around month 16. For establishment of organ culture systems for bivalves, Manila clam gonads were cultured in 15% L-15 medium diluted with HBSS containing 10% KSR on agarose gel at 10°C, and the gonads survived for 14 days. Scallop gonads were also able to be cultured in 30% L15 medium diluted with ASW containing 10% KSR on agarose gel for seven days. At mature stage, Foxl2 and Tesk were predominantly expressed in ovary and testis, respectively. When scallop gonads at sex reversal stage were organ-cultured, sex steroid treatment decreased Tesk expression in the majority of scallop gonads at sex reversal stage. However, no obvious change in Foxl2 and Tesk expression was detected in mature gonads in response to either E 2 or T in culture, suggesting sex steroid treatment might affect gonadal development at sex reversal stage.

  15. Iodine retention during evaporative volume reduction

    DOEpatents

    Godbee, H.W.; Cathers, G.I.; Blanco, R.E.

    1975-11-18

    An improved method for retaining radioactive iodine in aqueous waste solutions during volume reduction is disclosed. The method applies to evaporative volume reduction processes whereby the decontaminated (evaporated) water can be returned safely to the environment. The method generally comprises isotopically diluting the waste solution with a nonradioactive iodide and maintaining the solution at a high pH during evaporation.

  16. Trace element geochemistry of Archean volcanic rocks

    NASA Technical Reports Server (NTRS)

    Jahn, B.-M.; Shih, C.-Y.; Murthy, V. R.

    1974-01-01

    The K, Rb, Sr, Ba and rare-earth-element contents of some Archean volcanic rocks from the Vermilion greenstone belt, northeast Minnesota, were determined by the isotopic dilution method. The characteristics of trace element abundances, supported by the field occurrences and major element chemistry, suggest that these volcanic rocks were formed in an ancient island arc system.

  17. Repletion of branched chain amino acids reverses mTORC1 signaling but not improved metabolism during dietary protein dilution.

    PubMed

    Maida, Adriano; Chan, Jessica S K; Sjøberg, Kim A; Zota, Annika; Schmoll, Dieter; Kiens, Bente; Herzig, Stephan; Rose, Adam J

    2017-08-01

    Dietary protein dilution (PD) has been associated with metabolic advantages such as improved glucose homeostasis and increased energy expenditure. This phenotype involves liver-induced release of FGF21 in response to amino acid insufficiency; however, it has remained unclear whether dietary dilution of specific amino acids (AAs) is also required. Circulating branched chain amino acids (BCAAs) are sensitive to protein intake, elevated in the serum of obese humans and mice and thought to promote insulin resistance. We tested whether replenishment of dietary BCAAs to an AA-diluted (AAD) diet is sufficient to reverse the glucoregulatory benefits of dietary PD. We conducted AA profiling of serum from healthy humans and lean and high fat-fed or New Zealand obese (NZO) mice following dietary PD. We fed wildtype and NZO mice one of three amino acid defined diets: control, total AAD, or the same diet with complete levels of BCAAs (AAD + BCAA). We quantified serum AAs and characterized mice in terms of metabolic efficiency, body composition, glucose homeostasis, serum FGF21, and tissue markers of the integrated stress response (ISR) and mTORC1 signaling. Serum BCAAs, while elevated in serum from hyperphagic NZO, were consistently reduced by dietary PD in humans and murine models. Repletion of dietary BCAAs modestly attenuated insulin sensitivity and metabolic efficiency in wildtype mice but did not restore hyperglycemia in NZO mice. While hepatic markers of the ISR such as P-eIF2α and FGF21 were unabated by dietary BCAA repletion, hepatic and peripheral mTORC1 signaling were fully or partially restored, independent of changes in circulating glucose or insulin. Repletion of BCAAs in dietary PD is sufficient to oppose changes in somatic mTORC1 signaling but does not reverse the hepatic ISR nor induce insulin resistance in type 2 diabetes during dietary PD.

  18. Qualification and initial characterization of a high-purity 233U spike for use in uranium analyses

    DOE PAGES

    Mathew, K. J.; Canaan, R. D.; Hexel, C.; ...

    2015-08-20

    Several high-purity 233U items potentially useful as isotope dilution mass spectrometry standards for safeguards, non-proliferation, and nuclear forensics measurements are identified and rescued from downblending. By preserving the supply of 233U materials of different pedigree for use as source materials for certified reference materials (CRMs), it is ensured that the safeguards community has high quality uranium isotopic standards required for calibration of the analytical instruments. One of the items identified as a source material for a high-purity CRM is characterized for the uranium isotope-amount ratios using thermal ionization mass spectrometry (TIMS). Additional verification measurements on this material using quadrupole inductivelymore » coupled plasma mass spectrometry (ICPMS) are also performed. As a result, the comparison of the ICPMS uranium isotope-amount ratios with the TIMS data, with much smaller uncertainties, validated the ICPMS measurement practices. ICPMS is proposed for the initial screening of the purity of items in the rescue campaign.« less

  19. A simple physical mechanism enables homeostasis in primitive cells

    NASA Astrophysics Data System (ADS)

    Engelhart, Aaron E.; Adamala, Katarzyna P.; Szostak, Jack W.

    2016-05-01

    The emergence of homeostatic mechanisms that enable maintenance of an intracellular steady state during growth was critical to the advent of cellular life. Here, we show that concentration-dependent reversible binding of short oligonucleotides, of both specific and random sequence, can modulate ribozyme activity. In both cases, catalysis is inhibited at high concentrations, and dilution activates the ribozyme via inhibitor dissociation, thus maintaining near-constant ribozyme specific activity throughout protocell growth. To mimic the result of RNA synthesis within non-growing protocells, we co-encapsulated high concentrations of ribozyme and oligonucleotides within fatty acid vesicles, and ribozyme activity was inhibited. Following vesicle growth, the resulting internal dilution produced ribozyme activation. This simple physical system enables a primitive homeostatic behaviour: the maintenance of constant ribozyme activity per unit volume during protocell volume changes. We suggest that such systems, wherein short oligonucleotides reversibly inhibit functional RNAs, could have preceded sophisticated modern RNA regulatory mechanisms, such as those involving miRNAs.

  20. Application of iron and zinc isotopes to track the sources and mechanisms of metal loading in a mountain watershed

    USGS Publications Warehouse

    Borrok, D.M.; Wanty, R.B.; Ian, Ridley W.; Lamothe, P.J.; Kimball, B.A.; Verplanck, P.L.; Runkel, R.L.

    2009-01-01

    Here the hydrogeochemical constraints of a tracer dilution study are combined with Fe and Zn isotopic measurements to pinpoint metal loading sources and attenuation mechanisms in an alpine watershed impacted by acid mine drainage. In the tested mountain catchment, ??56Fe and ??66Zn isotopic signatures of filtered stream water samples varied by ???3.5??? and 0.4???, respectively. The inherent differences in the aqueous geochemistry of Fe and Zn provided complimentary isotopic information. For example, variations in ??56Fe were linked to redox and precipitation reactions occurring in the stream, while changes in ??66Zn were indicative of conservative mixing of different Zn sources. Fen environments contributed distinctively light dissolved Fe (<-2.0???) and isotopically heavy suspended Fe precipitates to the watershed, while Zn from the fen was isotopically heavy (>+0.4???). Acidic drainage from mine wastes contributed heavier dissolved Fe (???+0.5???) and lighter Zn (???+0.2???) isotopes relative to the fen. Upwelling of Fe-rich groundwater near the mouth of the catchment was the major source of Fe (??56Fe ??? 0???) leaving the watershed in surface flow, while runoff from mining wastes was the major source of Zn. The results suggest that given a strong framework for interpretation, Fe and Zn isotopes are useful tools for identifying and tracking metal sources and attenuation mechanisms in mountain watersheds. ?? 2009 Elsevier Ltd.

  1. Radiochemical separation of gallium by amalgam exchange

    USGS Publications Warehouse

    Ruch, R.R.

    1969-01-01

    An amalgam-exchange separation of radioactive gallium from a number of interfering radioisotopes has been developed. A dilute (ca. 0.3%) gallium amalgam is agitated with a slightly acidic solution of 72Ga3+ containing concentrations of sodium thiocyanate and either perchlorate or chloride. The amalgam is then removed and the radioactive gallium stripped by agitation with dilute nitric acid. The combined exchange yield of the perchlorate-thiocyanate system is 90??4% and that of the chloride-thiocyanate system is 75??4%. Decontamination yields of most of the 11 interfering isotopes studied were less than 0.02%. The technique is applicable for use with activation analysis for the determination of trace amounts of gallium. ?? 1969.

  2. An approach for quantification of platinum distribution in tissues by LA-ICP-MS imaging using isotope dilution analysis.

    PubMed

    Moraleja, I; Mena, M L; Lázaro, A; Neumann, B; Tejedor, A; Jakubowski, N; Gómez-Gómez, M M; Esteban-Fernández, D

    2018-02-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) has been revealed as a convenient technique for trace elemental imaging in tissue sections, providing elemental 2D distribution at a quantitative level. For quantification purposes, in the last years several approaches have been proposed in the literature such as the use of CRMs or matrix matched standards. The use of Isotope Dilution (ID) for quantification by LA-ICP-MS has been also described, being mainly useful for bulk analysis but not feasible for spatial measurements so far. In this work, a quantification method based on ID analysis was developed by printing isotope-enriched inks onto kidney slices from rats treated with antitumoral Pt-based drugs using a commercial ink-jet device, in order to perform an elemental quantification in different areas from bio-images. For the ID experiments 194 Pt enriched platinum was used. The methodology was validated by deposition of natural Pt standard droplets with a known amount of Pt onto the surface of a control tissue, where could be quantified even 50pg of Pt, with recoveries higher than 90%. The amount of Pt present in the whole kidney slices was quantified for cisplatin, carboplatin and oxaliplatin-treated rats. The results obtained were in accordance with those previously reported. The amount of Pt distributed between the medullar and cortical areas was also quantified, observing different behavior for the three drugs. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Capture of the volatile carbonyl metabolite of flecainide on 2,4-dinitrophenylhydrazine cartridge for quantitation by stable-isotope dilution mass spectrometry coupled with chromatography

    PubMed Central

    Prokai, Laszlo; Szarka, Szabolcs; Wang, Xiaoli; Prokai-Tatrai, Katalin

    2012-01-01

    Carbonyl compounds are common byproducts of many metabolic processes. These volatile chemical entities are usually derivatized before mass spectrometric analysis to enhance the sensitivity of their detections. The classically used reagent for this purpose is 2,4-dinitrophenylhydrazine (DNPH) that forms the corresponding hydrazones. When DNPH is immobilized on specific cartridges it permits solvent-free collection and simultaneous derivatization of aldehydes and ketones from gaseous samples. The utility of this approach was tested by assembling a simple apparatus for the in vitro generation of trifluoroacetaldehyde (TFAA) and its subsequent capture on the attached DNPH cartridge. TFAA was generated via cytochrome P450-catalyzed dealkylation of flecainide, an antiarrhythmic agent, in pooled human liver microsomes. Stable-isotope dilution mass spectrometry coupled with GC and LC using negative chemical ionization (NCI) and electrospray ionization (ESI) was evaluated for quantitative analyses. To eliminate isotope effects observed with the use of deuterium-labeled DNPH, we selected its 15N4-labeled analog to synthesize the appropriate TFAA adduct, as internal standard. Quantitation by GC–NCI-MS using selected-ion monitoring outperformed LC–ESI-MS methods considering limits of detection and linearity of the assays. The microsomal metabolism of 1.5 μmol of flecainide for 1.5 h resulted in 2.6 ± 0.5 μg TFAA-DNPH, corresponding to 9.3 ± 1.7 nmol TFAA, captured by the cartridge. PMID:22342210

  4. Capture of the volatile carbonyl metabolite of flecainide on 2,4-dinitrophenylhydrazine cartridge for quantitation by stable-isotope dilution mass spectrometry coupled with chromatography.

    PubMed

    Prokai, Laszlo; Szarka, Szabolcs; Wang, Xiaoli; Prokai-Tatrai, Katalin

    2012-04-06

    Carbonyl compounds are common byproducts of many metabolic processes. These volatile chemicals are usually derivatized before mass spectrometric analysis to enhance the sensitivity of their detections. The classically used reagent for this purpose is 2,4-dinitrophenylhydrazine (DNPH) that forms the corresponding hydrazones. When DNPH is immobilized on specific cartridges it permits solvent-free collection and simultaneous derivatization of aldehydes and ketones from gaseous samples. The utility of this approach was tested by assembling a simple apparatus for the in vitro generation of trifluoroacetaldehyde (TFAA) and its subsequent capture on the attached DNPH cartridge. TFAA was generated via cytochrome P450-catalyzed dealkylation of flecainide, an antiarrhythmic agent, in pooled human liver microsomes. Stable-isotope dilution mass spectrometry coupled with GC and LC using negative chemical ionization (NCI) and electrospray ionization (ESI) was evaluated for quantitative analyses. To eliminate isotope effects observed with the use of deuterium-labeled DNPH, we selected its (15)N(4)-labeled analog to synthesize the appropriate TFAA adduct, as internal standard. Quantitation by GC-NCI-MS using selected-ion monitoring outperformed LC-ESI-MS methods considering limits of detection and linearity of the assays. The microsomal metabolism of 1.5 μmol of flecainide for 1.5h resulted in 2.6 ± 0.5 μg TFAA-DNPH, corresponding to 9.3 ± 1.7 nmol TFAA, captured by the cartridge. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Non-labile silver species in biosolids remain stable throughout ...

    EPA Pesticide Factsheets

    Increasing commercial use of nanosilver has focussed attention on the fate of silver (Ag) in the wastewater release pathway. This paper reports the speciation and lability of Ag in archived, stockpiled, and contemporary biosolids from the UK, USA and Australia, and indicates that biosolids Ag concentrations have decreased significantly over recent decades. XANES revealed the importance of reduced-sulfur binding environments for Ag speciation in materials ranging from freshly produced sludge to biosolids weathered under ambient environmental conditions for more than 50 years. Isotopic dilution with 110mAg showed that Ag was predominantly non-labile in both fresh and aged biosolids (13.7% mean lability), with E-values ranging from 0.3 to 60 mg/kg and 5 mM CaNO3 extractable Ag from 1.2 to 609 µg/kg (0.002 - 3.4% of the total Ag). This study indicates that at the time of soil application, biosolids Ag will be predominantly Ag-sulfides and characterised by low isotopic lability. This paper presents an overview of biosolids Ag chemistry in historic and contemporary biosolids sourced from the UK, USA and Australia from the 1950s until today by drawing on a unique collection of archived, stockpiled and contemporary biosolids samples. Characteristics of biosolids Ag chemistry determined in this study included total Ag measurement by neutron activation analysis (NAA); the assessment of Ag lability by 110mAg isotopic dilution (E-values); and Ag speciation by X-ray Absorp

  6. Evaluation of online carbon isotope dilution mass spectrometry for the purity assessment of synthetic peptide standards.

    PubMed

    Cueto Díaz, Sergio; Ruiz Encinar, Jorge; García Alonso, J Ignacio

    2014-09-24

    We present a novel method for the purity assessment of peptide standards which is applicable to any water soluble peptide. The method is based on the online (13)C isotope dilution approach in which the peptide is separated from its related impurities by liquid chromatography (LC) and the eluent is mixed post-column with a continuous flow of (13)C-enriched sodium bicarbonate. An online oxidation step using sodium persulfate in acidic media at 99°C provides quantitative oxidation to (12)CO2 and (13)CO2 respectively which is extracted to a gaseous phase with the help of a gas permeable membrane. The measurement of the isotope ratio 44/45 in the mass spectrometer allows the construction of the mass flow chromatogram. As the only species that is finally measured in the mass spectrometer is CO2, the peptide content in the standard can be quantified, on the base of its carbon content, using a generic primary standard such as potassium hydrogen phthalate. The approach was validated by the analysis of a reference material (NIST 8327), and applied to the quantification of two commercial synthetic peptide standards. In that case, the results obtained were compared with those obtained using alternative methods, such as amino acid analysis and ICP-MS. The results obtained proved the value of the method for the fast, accurate and precise mass purity assignment of synthetic peptide standards. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Isotope pattern deconvolution as a tool to study iron metabolism in plants.

    PubMed

    Rodríguez-Castrillón, José Angel; Moldovan, Mariella; García Alonso, J Ignacio; Lucena, Juan José; García-Tomé, Maria Luisa; Hernández-Apaolaza, Lourdes

    2008-01-01

    Isotope pattern deconvolution is a mathematical technique for isolating distinct isotope signatures from mixtures of natural abundance and enriched tracers. In iron metabolism studies measurement of all four isotopes of the element by high-resolution multicollector or collision cell ICP-MS allows the determination of the tracer/tracee ratio with simultaneous internal mass bias correction and lower uncertainties. This technique was applied here for the first time to study iron uptake by cucumber plants using 57Fe-enriched iron chelates of the o,o and o,p isomers of ethylenediaminedi(o-hydroxyphenylacetic) acid (EDDHA) and ethylenediamine tetraacetic acid (EDTA). Samples of root, stem, leaves, and xylem sap, after exposure of the cucumber plants to the mentioned 57Fe chelates, were collected, dried, and digested using nitric acid. The isotopic composition of iron in the samples was measured by ICP-MS using a high-resolution multicollector instrument. Mass bias correction was computed using both a natural abundance iron standard and by internal correction using isotope pattern deconvolution. It was observed that, for plants with low 57Fe enrichment, isotope pattern deconvolution provided lower tracer/tracee ratio uncertainties than the traditional method applying external mass bias correction. The total amount of the element in the plants was determined by isotope dilution analysis, using a collision cell quadrupole ICP-MS instrument, after addition of 57Fe or natural abundance Fe in a known amount which depended on the isotopic composition of the sample.

  8. High Throughput Determination of Ricinine Abrine and Alpha ...

    EPA Pesticide Factsheets

    Analytical Method This document provides the standard operating procedure for determination of ricinine (RIC), abrine (ABR), and α-amanitin (AMAN) in drinking water by isotope dilution liquid chromatography tandem mass spectrometry (LC/MS/MS). This method is designed to support site-specific cleanup goals of environmental remediation activities following a homeland security incident involving one or a combination of these analytes.

  9. Quantitation of 4-Methyl-4-sulfanylpentan-2-one (4MSP) in Hops by a Stable Isotope Dilution Assay in Combination with GC×GC-TOFMS: Method Development and Application To Study the Influence of Variety, Provenance, Harvest Year, and Processing on 4MSP Concentrations.

    PubMed

    Reglitz, Klaas; Steinhaus, Martin

    2017-03-22

    A stable isotope dilution assay was developed for quantitation of 4-methyl-4-sulfanylpentan-2-one (4MSP) in hops. The approach included the use of 4-( 13 C)methyl-4-sulfanyl(1,3,5- 13 C 3 )pentan-2-one as internal standard, selective isolation of hop thiols by mercurated agarose, and GC×GC-TOFMS analysis. Application of the method to 53 different hop samples revealed 4MSP concentrations between <1 and 114 μg/kg. Notably high concentrations were associated with United States varieties such as Citra, Eureka, Simcoe, and Apollo, whereas 4MSP was absent from traditional German and English varieties. Further experiments showed that besides the variety, also harvest year and storage vitally influenced 4MSP concentrations, whereas the impact of provenance was less pronounced. Hop processing such as drying and pelletizing had only a minor impact on 4MSP concentrations. Like the majority of other hop volatiles, 4MSP is predominantly located in the lupulin glands.

  10. Fast and solvent-free quantitation of boar taint odorants in pig fat by stable isotope dilution analysis-dynamic headspace-thermal desorption-gas chromatography/time-of-flight mass spectrometry.

    PubMed

    Fischer, Jochen; Haas, Torsten; Leppert, Jan; Lammers, Peter Schulze; Horner, Gerhard; Wüst, Matthias; Boeker, Peter

    2014-09-01

    Boar taint is a specific off-odour of boar meat products, known to be caused by at least three unpleasant odorants, with very low odour thresholds. Androstenone is a boar pheromone produced in the testes, whereas skatole and indole originate from the microbial breakdown of tryptophan in the intestinal tract. A new procedure, applying stable isotope dilution analysis (SIDA) and dynamic headspace-thermal desorption-gas chromatography/time-of-flight mass spectrometry (dynHS-TD-GC/TOFMS) for the simultaneous quantitation of these boar taint compounds in pig fat was elaborated and validated in this paper. The new method is characterised by a simple and solvent-free dynamic headspace sampling. The deuterated compounds d3-androstenone, d3-skatole and d6-indole were used as internal standards to eliminate matrix effects. The method validation performed revealed low limits of detection (LOD) and quantitation (LOQ) with high accuracy and precision, thus confirming the feasibility of the new dynHS-TD-GC/TOFMS approach for routine analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Isotope dilution gas chromatography with mass spectrometry for the analysis of 4-octyl phenol, 4-nonylphenol, and bisphenol A in vegetable oils.

    PubMed

    Wu, Pinggu; Zhang, Liqun; Yang, Dajin; Zhang, Jing; Hu, Zhengyan; Wang, Liyuan; Ma, Bingjie

    2016-03-01

    By the combination of solid-phase extraction as well as isotope dilution gas chromatography with mass spectrometry, a sensitive and reliable method for the determination of endocrine-disrupting chemicals including bisphenol A, 4-octylphenol, and 4-nonylphenol in vegetable oils was established. The application of a silica/N-(n-propyl)ethylenediamine mixed solid-phase extraction cartridge achieved relatively low matrix effects for bisphenol A, 4-octylphenol, and 4-nonylphenol in vegetable oils. Experiments were designed to evaluate the effects of derivatization, and the extraction parameters were optimized. The estimated limits of detection and quantification for bisphenol A, 4-octylphenol, and 4-nonylphenol were 0.83 and 2.5 μg/kg, respectively. In a spiked experiment in vegetable oils, the recovery of the added bisphenol A was 97.5-110.3%, recovery of the added 4-octylphenol was 64.4-87.4%, and that of 4-nonylphenol was 68.2-89.3%. This sensitive method was then applied to real vegetable oil samples from Zhejiang Province of China, and none of the target compounds were detected. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Determination of mercury in SRM crude oils and refined products by isotope dilution cold vapor ICP-MS using closed-system combustion.

    PubMed

    Kelly, W Robert; Long, Stephen E; Mann, Jacqueline L

    2003-07-01

    Mercury was determined by isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICP-MS) in four different liquid petroleum SRMs. Samples of approximately 0.3 g were spiked with stable (201)Hg and wet ashed in a closed system (Carius tube) using 6 g of high-purity nitric acid. Three different types of commercial oils were measured: two Texas crude oils, SRM 2721 (41.7+/-5.7 pg g(-1)) and SRM 2722 (129+/-13 pg g(-1)), a low-sulfur diesel fuel, SRM 2724b (34+/-26 pg g(-1)), and a low-sulfur residual fuel oil, SRM 1619b (3.5+/-0.74 ng g(-1)) (mean value and 95% CI). The Hg values for the crude oils and the diesel fuel are the lowest values ever reported for these matrices. The method detection limit, which is ultimately limited by method blank uncertainty, is approximately 10 pg g(-1) for a 0.3 g sample. Accurate Hg measurements in petroleum products are needed to assess the contribution to the global Hg cycle and may be needed in the near future to comply with reporting regulations for toxic elements.

  13. Quantitation of Thioprolines in Grape Wine by Isotope Dilution-Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Liu, Jingjing; Meng, Xiangpeng; Chan, Wan

    2016-02-17

    Cysteine reacts with reactive carbonyls to form thioprolines, which have been demonstrated to possess various pharmaceutical properties. Therefore, thioproline formation is considered as a major detoxification pathway for carcinogenic reactive carbonyls. In this study, we report the initial identification of thiazolidine-4-carboxylic acid (1) and 2-methylthiazolidine-4-carboxylic acid (2), two very common thioprolines, formed by reacting formaldehyde and acetaldehyde with cysteine in grape wine samples. We have developed an isotope dilution-liquid chromatography-tandem mass spectrometry method featuring high sensitivity (limit of detection of ≤1.5 ng/mL) and selectivity to quantitate compounds 1 and 2. The method after validated to be highly accurate (recovery of ≥92%) and precise [intraday relative standard deviation (RSD) of ≤4.1% and interday RSD of ≤9.7%] was applied to determine the varying compound 1 and 2 contents in grape wine samples. Results revealed the grape type and storage duration-dependent formation of thioprolines in grape wines. Overall, the results are expected to facilitate compound-dependent investigations of the health benefits of grape wine, and our findings could be adopted to predict the age of grape wine.

  14. Effects of inertia on the steady shear rheology of concentrated emulsions: sign reversal of normal stress differences

    NASA Astrophysics Data System (ADS)

    Srivastava, Priyesh; Sarkar, Kausik

    2012-11-01

    The shear rheology of moderately concentrated emulsions (5-27% volume fraction) in the presence of inertia is numerically investigated. Typically, an emulsion of viscous drops experiences positive first normal stress difference (N1) and negative second normal stress difference (N2) , as has also been predicted by perturbative analysis (Choi-Schowalter model) and numerical simulation. However, recently using single drop results we have shown [Li and Sarkar, 2005, J. Rheo, 49, 1377] that introduction of inertia reverses the signs of the normal stress difference in the dilute limit. Here, we numerically investigate the effects of interactions between drops in a concentrated system. The simulation is validated against the dilute results as well as analytical relations. It also shows the reversal of signs for N1 and N2 for small Capillary numbers above a critical Reynolds number. The physics is explained by the inertia-induced orientation of the individual drops in shear. Increasing volume fraction increases the critical Reynolds number at which N1 and N2change sign. The breakdown of linearity with volume fraction with increasing concentration is also analyzed. Partially supported by NSF.

  15. Platinum isotopes in iron meteorites: Galactic cosmic ray effects and nucleosynthetic homogeneity in the p-process isotope 190Pt and the other platinum isotopes

    NASA Astrophysics Data System (ADS)

    Hunt, Alison C.; Ek, Mattias; Schönbächler, Maria

    2017-11-01

    Platinum isotopes are sensitive to the effects of galactic cosmic rays (GCR), which can alter isotope ratios and mask nucleosynthetic isotope variations. Platinum also features one p-process isotope, 190Pt, which is very low abundance and therefore challenging to analyse. Platinum-190 is relevant for early solar-system chronology because of its decay to 186Os. Here, we present new Pt isotope data for five iron meteorite groups (IAB, IIAB, IID, IIIAB and IVA), including high-precision measurements of 190Pt for the IAB, IIAB and IIIAB irons, determined by multi-collector ICPMS. New data are in good agreement with previous studies and display correlations between different Pt isotopes. The slopes of these correlations are well-reproduced by the available GCR models. We report Pt isotope ratios for the IID meteorite Carbo that are consistently higher than the predicted effects from the GCR model. This suggests that the model predictions do not fully account for all the GCR effects on Pt isotopes, but also that the pre-atmospheric radii and exposure times calculated for Carbo may be incorrect. Despite this, the good agreement of relative effects in Pt isotopes with the predicted GCR trends confirms that Pt isotopes are a useful in-situ neutron dosimeter. Once GCR effects are accounted for, our new dataset reveals s- and r-process homogeneity between the iron meteorite groups studied here and the Earth. New 190Pt data for the IAB, IIAB and IIIAB iron meteorites indicate the absence of GCR effects and homogeneity in the p-process isotope between these groups and the Earth. This corresponds well with results from other heavy p-process isotopes and suggests their homogenous distribution in the inner solar system, although it does not exclude that potential p-process isotope variations are too diluted to be currently detectable.

  16. Continuous countercurrent membrane column for the separation of solute/solvent and solvent/solvent systems

    DOEpatents

    Nerad, Bruce A.; Krantz, William B.

    1988-01-01

    A reverse osmosis membrane process or hybrid membrane - complementary separator process for producing enriched product or waste streams from concentrated and dilute feed streams for both solvent/solvent and solute/solvent systems is described.

  17. Myosin Va Bound to Phagosomes Binds to F-Actin and Delays Microtubule-dependent Motility

    PubMed Central

    Al-Haddad, Ahmed; Shonn, Marion A.; Redlich, Bärbel; Blocker, Ariel; Burkhardt, Janis K.; Yu, Hanry; Hammer, John A.; Weiss, Dieter G.; Steffen, Walter; Griffiths, Gareth; Kuznetsov, Sergei A.

    2001-01-01

    We established a light microscopy-based assay that reconstitutes the binding of phagosomes purified from mouse macrophages to preassembled F-actin in vitro. Both endogenous myosin Va from mouse macrophages and exogenous myosin Va from chicken brain stimulated the phagosome–F-actin interaction. Myosin Va association with phagosomes correlated with their ability to bind F-actin in an ATP-regulated manner and antibodies to myosin Va specifically blocked the ATP-sensitive phagosome binding to F-actin. The uptake and retrograde transport of phagosomes from the periphery to the center of cells in bone marrow macrophages was observed in both normal mice and mice homozygous for the dilute-lethal spontaneous mutation (myosin Va null). However, in dilute-lethal macrophages the accumulation of phagosomes in the perinuclear region occurred twofold faster than in normal macrophages. Motion analysis revealed saltatory phagosome movement with temporarily reversed direction in normal macrophages, whereas almost no reversals in direction were observed in dilute-lethal macrophages. These observations demonstrate that myosin Va mediates phagosome binding to F-actin, resulting in a delay in microtubule-dependent retrograde phagosome movement toward the cell center. We propose an “antagonistic/cooperative mechanism” to explain the saltatory phagosome movement toward the cell center in normal macrophages. PMID:11553713

  18. Proxy Records of the Indonesian Low and the El Ni{tilde n}o-Southern Oscillation (ENSO) from Stable Isotope Measurements of Indonesian Reef Corals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, M.D.

    1995-12-31

    The Earth`s largest atmospheric convective center is the Indonesian Low. It generates the Australasian monsoon, drives the zonal tropospheric Walker Circulation, and is implicated in the genesis of the El Nino-Southern Oscillation (ENSO). The long-term variability of the Indonesian Low is poorly characterized, yet such information is crucial for evaluating whether changes in the strength and frequency of ENSO events are a possible manifestation of global warming. Stable oxygen isotope ratios ({delta}{sup 18}O) in shallow-water reef coral skeletons track topical convective activity over hundreds of years because the input of isotopically-depleted rainwater dilutes seawater {delta}{sup 18}O. Corals also impose amore » temperature-dependent fractionation on {delta}{sup 18}O, but where annual rainfall is high and sea surface temperature (SST) variability is low the freshwater flux effect dominates.« less

  19. Evaluation of carbon isotope fractionation during anaerobic reductive dehalogenation of chlorinated and brominated benzenes.

    PubMed

    Sohn, Seo Yean; Kuntze, Kevin; Nijenhuis, Ivonne; Häggblom, Max M

    2018-02-01

    Compound specific stable isotope analysis (CSIA) has been established as a useful tool to evaluate in situ biodegradation. Here, CSIA was used to determine microbial dehalogenation of chloro- and bromobenzenes in microcosms derived from Hackensack River sediments. Gas chromatography-isotope ratio mass spectrometry (GC-IRMS) was used to measure carbon isotope fractionation during reductive dehalogenation of hexachlorobenzene (HCB), pentachlorobenzene (PeCB), 1,2,3,5-tetrachlorobenzene (TeCB), 1,2,3,5-tetrabromobenzene (TeBB), and 1,3,5-tribromobenzene (TriBB). Strong evidence of isotope fractionation coupled to dehalogenation was not observed in the substrate, possibly due to the low solubilities of the highly halogenated benzene substrates and a dilution of the isotope signal. Nonetheless, we could measure a depletion of the δ 13 C value in the dichlorobenzene product during dechlorination of HCB, the sequential depletion and enrichment of δ 13 C value for trichlorobenzene in TeCB dechlorinating cultures, and the enrichment of δ 13 C during debromination of TriBB. This indicates that a measurable isotope fractionation occurred during reductive dehalogenation of highly halogenated chloro- and bromobenzenes in aquatic sediments. Thus, although more quantitative measurements will be needed, the data suggests that CSIA may have application for monitoring in situ microbial reductive dehalogenation of highly halogenated benzenes. Copyright © 2017. Published by Elsevier Ltd.

  20. Polarization IR spectra of hydrogen bonded pyrazole crystals: self-organization effects in proton and deuteron mixture systems. Long-range H/D isotopic effects

    NASA Astrophysics Data System (ADS)

    Flakus, Henryk T.; Machelska, Aleksandra

    2002-02-01

    This paper deals with experimental studies of the polarization IR spectra of solid-state pyrazole H1345, as well as of its H1D345, D1H345 and D1345 deuterium derivatives. Spectra were measured for the νNH and νND band frequency ranges at temperatures of 298 and 77 K. The spectra were found to strongly change their intensity distribution and their polarization properties with the decrease of temperature. These effects were ascribed to some temperature-induced conformational changes in the hydrogen bond lattices. The studies reported allowed the finding of new kind of isotopic effects H/D in the open-chain hydrogen bond systems, i.e. the self-organization effects. It was found that the spectrally active aggregates of hydrogen bonds remain unchanged despite the growing isotope H/D exchange rate. This statement was supported by analysis of the residual polarized νNH and νND band properties, measured for the isotopically diluted crystalline samples. Analysis of the band shapes of the four hydrogen isotope derivative crystals proved the existence of another kind of H/D isotopic effect, i.e. the long-range isotopic effect. It depends on an influence of the pyrazole ring hydrogen atoms onto the νNH and νND band widths and onto the band fine structures.

  1. Odor-active constituents in fresh pineapple (Ananas comosus [L.] Merr.) by quantitative and sensory evaluation.

    PubMed

    Tokitomo, Yukiko; Steinhaus, Martin; Büttner, Andrea; Schieberle, Peter

    2005-07-01

    By application of aroma extract dilution analysis (AEDA) to an aroma distillate prepared from fresh pineapple using solvent-assisted flavor evaporation (SAFE), 29 odor-active compounds were detected in the flavor dilution (FD) factor range of 2 to 4,096. Quantitative measurements performed by stable isotope dilution assays (SIDA) and a calculation of odor activity values (OAVs) of 12 selected odorants revealed the following compounds as key odorants in fresh pineapple flavor: 4-hydroxy-2,5-dimethyl-3(2H)-furanone (HDF; sweet, pineapple-like, caramel-like), ethyl 2-methylpropanoate (fruity), ethyl 2-methylbutanoate (fruity) followed by methyl 2-methylbutanoate (fruity, apple-like) and 1-(E,Z)-3,5-undecatriene (fresh, pineapple-like). A mixture of these 12 odorants in concentrations equal to those in the fresh pineapple resulted in an odor profile similar to that of the fresh juice. Furthermore, the results of omission tests using the model mixture showed that HDF and ethyl 2-methylbutanoate are character impact odorants in fresh pineapple.

  2. Odor-Active Compounds in the Special Flavor Hops Huell Melon and Polaris.

    PubMed

    Neiens, Silva D; Steinhaus, Martin

    2018-02-14

    The volatiles isolated from samples of the special flavor hop varieties, Huell Melon and Polaris, and from the aroma hop variety, Hallertau Tradition, by solvent extraction and solvent-assisted flavor evaporation (SAFE) were subjected to a comparative aroma extract dilution analysis (cAEDA), which resulted in 46 odor-active compounds in the flavor dilution (FD) factor range of 16 to 2048. On the basis of high FD factors, myrcene, (3R)-linalool, and 2- and 3-methylbutanoic acid were confirmed as important variety-independent hop odorants. (1R,4S)-Calamenene was identified for the first time as an odor-active compound in hops. Clear differences in the FD factors and their subsequent objectification by stable isotope dilution quantitation suggested that high concentrations of the esters ethyl 2-methylbutanoate, ethyl 2-methylpropanoate, and propyl 2-methylbutanoate cause the characteristic fruity, cantaloupe-like odor note in Huell Melon hops, whereas the fruity and minty odor notes in Polaris are associated with high amounts of 3-methylbutyl acetate and 1,8-cineole.

  3. Laser ablation inductively coupled plasma mass spectrometry for direct isotope ratio measurements on solid samples

    NASA Astrophysics Data System (ADS)

    Pickhardt, Carola; Dietze, Hans-Joachim; Becker, J. Sabine

    2005-04-01

    Isotope ratio measurements have been increasingly used in quite different application fields, e.g., for the investigation of isotope variation in nature, in geoscience (geochemistry and geochronology), in cosmochemistry and planetary science, in environmental science, e.g., in environmental monitoring, or by the application of the isotope dilution technique for quantification purposes using stable or radioactive high-enriched isotope tracers. Due to its high sensitivity, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is today a challenging mass spectrometric technique for the direct determination of precise and accurate isotope ratios in solid samples. In comparison to laser ablation quadrupole ICP-MS (LA-ICP-QMS), laser ablation coupled to a double-focusing sector field ICP-MS (LA-ICP-SFMS) with single ion detection offers a significant improvement of sensitivity at low mass resolution, whereby isotope ratios can be measured with a precision to 0.1% relative standard deviation (R.S.D.). In LA-ICP-SFMS, many disturbing isobaric interferences of analyte and molecular ions can be separated at the required mass resolution (e.g., 40Ar16O+ and 56Fe+ for iron isotope ratio measurements). The precision on isotope ratio measurements was improved by one order of magnitude via the simultaneous detection of mass-separated ion currents of isotopes using multiple ion collectors in LA-ICP-MS (LA-MC-ICP-MS). The paper discusses the state of the art, the challenges and limits in isotope ratio measurements by LA-ICP-MS using different instrumentations at the trace and ultratrace level in different fields of application as in environmental and biological research, geochemistry and geochronology with respect to their precision and accuracy.

  4. Distribution of neptunium and plutonium in New Mexico lichen samples ( Usnea arizonica) contaminated by atmospheric fallout

    DOE PAGES

    Oldham, Jr., Warren J.; Hanson, Susan K.; Lavelle, Kevin B.; ...

    2015-08-30

    In this study, the concentrations of 237Np, 239Pu and 240Pu were determined in lichen samples ( Usnea arizonica) that were collected from ten locations in New Mexico between 2011 and 2013 using isotope dilution inductively-coupled plasma mass spectrometry (ID-ICP-MS). The observed isotopic ratios for 237Np/ 239Pu and 240Pu/ 239Pu indicate trace contamination from global and regional fallout (e.g. Trinity test and atmospheric testing at the Nevada Test Site). The fact that actinide contamination is detected in recent lichen collections suggests continuous re-suspension of fallout radionuclides even 50 years after ratification of the Limited Test Ban Treaty.

  5. Clustering Aspects in Nuclear Structure and Collisions

    NASA Astrophysics Data System (ADS)

    Horiuchi, H.

    Four topics on nuclear clustering are discussed. The first subject is about the cluster formation in dilute matter which we think is now observed in heavy ion collisions at hundreds MeV/nucleon. The second subject is about our new proposal of the existense of alpha condensed states in light nuclei. Two other subjects are both about the clustering in neutron-rich nuclei. One is the cluster structures in neutron-rich Be and B isotopes. In these isotopes, the clustering prevails as fundamental characters of nuclear structure. The other is the report of our recent study about the possible relation of the clustering with the breaking of the neutron magic number N=20 in 32Mg and 30Ne.

  6. Stable isotope labeling by essential nutrients in cell culture for preparation of labeled coenzyme A and its thioesters.

    PubMed

    Basu, Sankha S; Mesaros, Clementina; Gelhaus, Stacy L; Blair, Ian A

    2011-02-15

    Stable isotope dilution mass spectrometry (MS) represents the gold standard for quantification of endogenously formed cellular metabolites. Although coenzyme A (CoA) and acyl-CoA thioester derivatives are central players in numerous metabolic pathways, the lack of a commercially available isotopically labeled CoA limits the development of rigorous MS-based methods. In this study, we adapted stable isotope labeling by amino acids in cell culture (SILAC) methodology to biosynthetically generate stable isotope labeled CoA and thioester analogues for use as internal standards in liquid chromatography/multiple reaction monitoring mass spectrometry (LC/MRM-MS) assays. This was accomplished by incubating murine hepatocytes (Hepa 1c1c7) in media in which pantothenate (a precursor of CoA) was replaced with [(13)C(3)(15)N(1)]-pantothenate. Efficient incorporation into various CoA species was optimized to >99% [(13)C(3)(15)N(1)]-pantothenate after three passages of the murine cells in culture. Charcoal-dextran-stripped fetal bovine serum (FBS) was found to be more efficient for serum supplementation than dialyzed or undialyzed FBS, due to lower contaminating unlabeled pantothenate content. Stable isotope labeled CoA species were extracted and utilized as internal standards for CoA thioester analysis in cell culture models. This methodology of stable isotope labeling by essential nutrients in cell culture (SILEC) can serve as a paradigm for using vitamins and other essential nutrients to generate stable isotope standards that cannot be readily synthesized.

  7. New methods allowing the detection of protein aggregates

    PubMed Central

    Demeule, Barthélemy; Palais, Caroline; Machaidze, Gia; Gurny, Robert

    2009-01-01

    Aggregation compromises the safety and efficacy of therapeutic proteins. According to the manufacturer, the therapeutic immunoglobulin trastuzumab (Herceptin®) should be diluted in 0.9% sodium chloride before administration. Dilution in 5% dextrose solutions is prohibited. The reason for the interdiction is not mentioned in the Food and Drug Administration (FDA) documentation, but the European Medicines Agency (EMEA) Summary of Product Characteristics states that dilution of trastuzumab in dextrose solutions results in protein aggregation. In this paper, asymmetrical flow field-flow fractionation (FFF), fluorescence spectroscopy, fluorescence microscopy and transmission electron microscopy (TEM) have been used to characterize trastuzumab samples diluted in 0.9% sodium chloride, a stable infusion solution, as well as in 5% dextrose (a solution prone to aggregation). When trastuzumab samples were injected in the FFF channel using a standard separation method, no difference could be seen between trastuzumab diluted in sodium chloride and trastuzumab diluted in dextrose. However, during FFF measurements made with appropriate protocols, aggregates were detected in 5% dextrose. The parameters enabling the detection of reversible trastuzumab aggregates are described. Aggregates could also be documented by fluorescence microscopy and TEM. Fluorescence spectroscopy data were indicative of conformational changes consistent with increased aggregation and adsorption to surfaces. The analytical methods presented in this study were able to detect and characterize trastuzumab aggregates. PMID:20061815

  8. Fast switching of bistable magnetic nanowires through collective spin reversal

    NASA Astrophysics Data System (ADS)

    Vindigni, Alessandro; Rettori, Angelo; Bogani, Lapo; Caneschi, Andrea; Gatteschi, Dante; Sessoli, Roberta; Novak, Miguel A.

    2005-08-01

    The use of magnetic nanowires as memory units is made possible by the exponential divergence of the characteristic time for magnetization reversal at low temperature, but the slow relaxation makes the manipulation of the frozen magnetic states difficult. We suggest that finite-size segments can show a fast switching if collective reversal of the spins is taken into account. This mechanism gives rise at low temperatures to a scaling law for the dynamic susceptibility that has been experimentally observed for the dilute molecular chain Co(hfac)2NitPhOMe. These results suggest a possible way of engineering nanowires for fast switching of the magnetization.

  9. Determination of nitrogen-15 isotope fractionation in tropine: evaluation of extraction protocols for isotope ratio measurement by isotope ratio mass spectrometry.

    PubMed

    Molinié, Roland; Kwiecień, Renata A; Silvestre, Virginie; Robins, Richard J

    2009-12-01

    N-Demethylation of tropine is an important step in the degradation of this compound and related metabolites. With the purpose of understanding the reaction mechanism(s) involved, it is desirable to measure the 15N kinetic isotope effects (KIEs), which can be accessed through the 15N isotope shift (Deltadelta15N) during the reaction. To measure the isotope fractionation in 15N during tropine degradation necessitates the extraction of the residual substrate from dilute aqueous solution without introducing artefactual isotope fractionation. Three protocols have been compared for the extraction and measurement of the 15N/14N ratio of tropine from aqueous medium, involving liquid-liquid phase partitioning or silica-C18 solid-phase extraction. Quantification was by gas chromatography (GC) on the recovered organic phase and delta15N values were obtained by isotope ratio measurement mass spectrometry (irm-MS). Although all the protocols used can provide satisfactory data and both irm-EA-MS and irm-GC-MS can be used to obtain the delta15N values, the most convenient method is liquid-liquid extraction from a reduced aqueous volume combined with irm-GC-MS. The protocols are applied to the measurement of 15N isotope shifts during growth of a Pseudomonas strain that uses tropane alkaloids as sole source of carbon and nitrogen. The accuracy of the determination of the 15N/14N ratio is sufficient to be used for the determination of 15N-KIEs. Copyright 2009 John Wiley & Sons, Ltd.

  10. Water in the hydration shell of halide ions has significantly reduced Fermi resonance and moderately enhanced Raman cross section in the OH stretch regions.

    PubMed

    Ahmed, Mohammed; Singh, Ajay K; Mondal, Jahur A; Sarkar, Sisir K

    2013-08-22

    Water in the presence of electrolytes plays an important role in biological and industrial processes. The properties of water, such as the intermolecular coupling, Fermi resonance (FR), hydrogen-bonding, and Raman cross section were investigated by measuring the Raman spectra in the OD and OH stretch regions in presence of alkali halides (NaX; X = F, Cl, Br, I). It is observed that the changes in spectral characteristics by the addition of NaX in D2O are similar to those obtained by the addition of H2O in D2O. The spectral width decreases significantly by the addition of NaX in D2O (H2O) than that in the isotopically diluted water. Quantitative estimation, on the basis of integrated Raman intensity, revealed that the relative Raman cross section, σ(H)/σ(b) (σ(H) and σ(b) are the average Raman cross section of water in the first hydration shell of X(-) and in bulk, respectively), in D2O and H2O is higher than those in the respective isotopically diluted water. These results suggest that water in the hydration shell has reduced FR and intermolecular coupling compared to those in bulk. In the isotopically diluted water, the relative Raman cross section increases with increase in size of the halide ions (σ(H)/σ(b) = 0.6, 1.1, 1.5, and 1.9 for F(-), Cl(-), Br(-), and I(-), respectively), which is assignable to the enhancement of Raman cross section by charge transfer from halide ions to the hydrating water. Nevertheless, the experimentally determined σ(H)/σ(b) is lower than the calculated values obtained on the basis of the energy of the charge transfer state of water. The weak enhancement of σ(H)/σ(b) signifies that the charge transfer transition in the hydration shell of halide ions causes little change in the OD (OH) bond lengths of hydrating water.

  11. Use of chemistry and stable sulfur isotopes to determine sources of trends in sulfate of Colorado lakes

    USGS Publications Warehouse

    Turk, J.T.; Campbell, D.H.; Spahr, N.E.

    1993-01-01

    The chemistry of lakes in the Mt. Zukel Wilderness Area (MZWA) and the Weminuche Wilderness Area (WWA) of Colorado has been monitored since 1985. The initial results indicate that changes have occurred in the chemistry of some lakes in both areas. Increased concentration of sulfate in lakes may be related to increased atmospheric deposition of sulfate or to changes of sulfate released by weathering and to changing dilution of sulfate by snowmelt. Stable S isotopes seem to be capable of separating the fraction of change in sulfate that is related to atmospheric and watershed sources. Because of the short period of record, it is not possible to determine whether the changes are part of a long-term trend or are merely natural fluctuations about some baseline.The chemistry of lakes in th Mt. Zirkel Wilderness Area (MZWA) and Weminche Wilderness Area (WWA) of Colorado has been monitored since 1985. The initial results indicate that changes have occured in the chemistry of some lakes in both areas. Increased concentration of sulfate in lakes may be related to increased atmospheric deposition of sulfateor to changes of sulfate released by weathering and to changing dilution of sulfate by snowmelt. Stable S isotopes seem to be capable of separating the fraction of change in sulfate that is related to atmospheric and watershed sources. Because of the short period of record, it is not possible to determine whether the changes are part of long-term or are merely natural fluctuations about some baseline.

  12. Simultaneous determination of PPCPs, EDCs, and artificial sweeteners in environmental water samples using a single-step SPE coupled with HPLC-MS/MS and isotope dilution.

    PubMed

    Tran, Ngoc Han; Hu, Jiangyong; Ong, Say Leong

    2013-09-15

    A high-throughput method for the simultaneous determination of 24 pharmaceuticals and personal care products (PPCPs), endocrine disrupting chemicals (EDCs) and artificial sweeteners (ASs) was developed. The method was based on a single-step solid phase extraction (SPE) coupled with high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and isotope dilution. In this study, a single-step SPE procedure was optimized for simultaneous extraction of all target analytes. Good recoveries (≥ 70%) were observed for all target analytes when extraction was performed using Chromabond(®) HR-X (500 mg, 6 mL) cartridges under acidic condition (pH 2). HPLC-MS/MS parameters were optimized for the simultaneous analysis of 24 PPCPs, EDCs and ASs in a single injection. Quantification was performed by using 13 isotopically labeled internal standards (ILIS), which allows correcting efficiently the loss of the analytes during SPE procedure, matrix effects during HPLC-MS/MS and fluctuation in MS/MS signal intensity due to instrument. Method quantification limit (MQL) for most of the target analytes was below 10 ng/L in all water samples. The method was successfully applied for the simultaneous determination of PPCPs, EDCs and ASs in raw wastewater, surface water and groundwater samples collected in a local catchment area in Singapore. In conclusion, the developed method provided a valuable tool for investigating the occurrence, behavior, transport, and the fate of PPCPs, EDCs and ASs in the aquatic environment. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Quantification of ferritin bound iron in human serum using species-specific isotope dilution mass spectrometry.

    PubMed

    Ren, Yao; Walczyk, Thomas

    2014-09-01

    Ferritin is a hollow sphere protein composed of 24 subunits that can store up to 4500 iron atoms in its inner cavity. It is mainly found in the liver and spleen but also in serum at trace levels. Serum ferritin is considered as the best single indicator in assessing body iron stores except liver or bone marrow biopsy. However, it is confounded by other disease conditions. Ferritin bound iron (FBI) and ferritin saturation have been suggested as more robust biomarkers. The current techniques for FBI determination are limited by low antibody specificity, low instrument sensitivity and possible analyte losses during sample preparation. The need for a highly sensitive and reliable method is widely recognized. Here we describe a novel technique to detect serum FBI using species-specific isotope dilution mass spectrometry (SS-IDMS). [(57)Fe]-ferritin was produced by biosynthesis and in vitro labeling with the (57)Fe spike in the form of [(57)Fe]-citrate after cell lysis and heat treatment. [(57)Fe]-ferritin for sample spiking was further purified by fast liquid protein chromatography. Serum ferritin and added [(57)Fe]-ferritin were separated from other iron species by ultrafiltration followed by isotopic analysis of FBI using negative thermal ionization mass spectrometry. Repeatability of our assay is 8% with an absolute detection limit of 18 ng FBI in the sample. As compared to other speciation techniques, SS-IDMS offers maximum control over sample losses and species conversion during analysis. The described technique may therefore serve as a reference technique for clinical applications of FBI as a new biomarker for assessing body iron status.

  14. SHRIMP-RG U-Pb isotopic systematics of zircon from the Angel Lake orthogneiss, East Humboldt Range, Nevada: Is this really archean crust?

    USGS Publications Warehouse

    Premo, Wayne R.; Castineiras, Pedro; Wooden, Joseph L.

    2008-01-01

    New SHRIMP-RG (sensitive high-resolution ion microprobe-reverse geometry) data confirm the existence of Archean components within zircon grains of a sample from the orthogneiss of Angel Lake, Nevada, United States, previously interpreted as a nappe of Archean crust. However, the combined evidence strongly suggests that this orthogneiss is a highly deformed, Late Cretaceous monzogranite derived from melting of a sedimentary source dominated by Archean detritus. Zircon grains from the same sample used previously for isotope dilution-thermal ionization mass spectrometry (ID-TIMS) isotopic work were analyzed using the SHRIMP-RG to better define the age and origin of the orthogneiss. Prior to analysis, imaging revealed a morphological variability and intragrain, polyphase nature of the zircon population. The SHRIMP-RG yielded 207Pb/206Pb ages between ca. 2430 and 2580 Ma (a best-fit mean 207Pb/206Pb age of 2531 ± 19 Ma; 95% confidence) from mostly rounded to subrounded zircons and zircon components (cores). In addition, several analyses from rounded to subrounded cores or grains yielded discordant 207Pb/206Pb ages between ca. 1460 and ca. 2170 Ma, consistent with known regional magmatic events. All cores of Proterozoic to latest Archean age were encased within clear, typically low Th/U (206Pb/238U ages between 72 and 91 Ma, consistent with magmatic ages from Lamoille Canyon to the south. An age of ca. 90 Ma is suggested, the younger 206Pb/238U ages resulting from Pb loss. The Cretaceous and Precambrian zircon components also have distinct trace element characteristics, indicating that these age groups are not related to the same igneous source. These results support recent geophysical interpretations and negate the contention that the Archean-Proterozoic boundary extends into the central Great Basin area. They further suggest that the world-class gold deposits along the Carlin Trend are not underlain by Archean cratonal crust, but rather by the Proterozoic Mojave province and Neoproterozoic and Paleozoic metasedimentary sequences dominated by detritus derived from Late Archean sources rather than Proterozoic sources, as is evident farther to the south in the Ruby Mountains.

  15. A new dimethyl labeling-based SID-MRM-MS method and its application to three proteases involved in insulin maturation.

    PubMed

    Cheng, Dongwan; Zheng, Li; Hou, Junjie; Wang, Jifeng; Xue, Peng; Yang, Fuquan; Xu, Tao

    2015-01-01

    The absolute quantification of target proteins in proteomics involves stable isotope dilution coupled with multiple reactions monitoring mass spectrometry (SID-MRM-MS). The successful preparation of stable isotope-labeled internal standard peptides is an important prerequisite for the SID-MRM absolute quantification methods. Dimethyl labeling has been widely used in relative quantitative proteomics and it is fast, simple, reliable, cost-effective, and applicable to any protein sample, making it an ideal candidate method for the preparation of stable isotope-labeled internal standards. MRM mass spectrometry is of high sensitivity, specificity, and throughput characteristics and can quantify multiple proteins simultaneously, including low-abundance proteins in precious samples such as pancreatic islets. In this study, a new method for the absolute quantification of three proteases involved in insulin maturation, namely PC1/3, PC2 and CPE, was developed by coupling a stable isotope dimethyl labeling strategy for internal standard peptide preparation with SID-MRM-MS quantitative technology. This method offers a new and effective approach for deep understanding of the functional status of pancreatic β cells and pathogenesis in diabetes.

  16. Optimized demineralization technique for the measurement of stable isotope ratios of nonexchangeable H in soil organic matter.

    PubMed

    Ruppenthal, Marc; Oelmann, Yvonne; Wilcke, Wolfgang

    2013-01-15

    To make use of the isotope ratio of nonexchangeable hydrogen (δ(2)H(n (nonexchangeable))) of bulk soil organic matter (SOM), the mineral matrix (containing structural water of clay minerals) must be separated from SOM and samples need to be analyzed after H isotope equilibration. We present a novel technique for demineralization of soil samples with HF and dilute HCl and recovery of the SOM fraction solubilized in the HF demineralization solution via solid-phase extraction. Compared with existing techniques, organic C (C(org)) and organic N (N(org)) recovery of demineralized SOM concentrates was significantly increased (C(org) recovery using existing techniques vs new demineralization method: 58% vs 78%; N(org) recovery: 60% vs 78%). Chemicals used for the demineralization treatment did not affect δ(2)H(n) values as revealed by spiking with deuterated water. The new demineralization method minimized organic matter losses and thus artificial H isotope fractionation, opening up the opportunity to use δ(2)H(n) analyses of SOM as a new tool in paleoclimatology or geospatial forensics.

  17. Elicitor-Induced Association of Isoflavone O-Methyltransferase with Endomembranes Prevents the Formation and 7-O-Methylation of Daidzein during Isoflavonoid Phytoalexin Biosynthesis

    PubMed Central

    Liu, Chang-Jun; Dixon, Richard A.

    2001-01-01

    The bioactive isoflavonoids of the Leguminosae often are methylated on the 4′-position of their B-rings. Paradoxically, reverse genetic evidence implicates alfalfa isoflavone O-methyltransferase (IOMT) in the biosynthesis of 4′-O-methylated isoflavonoids such as the phytoalexin medicarpin in vivo, whereas biochemical studies indicate that IOMT has strict specificity for methylation of the A-ring 7-hydroxyl of daidzein, the presumed substrate for O-methylation, in vitro. Radiolabeling and isotope dilution studies now confirm that daidzein is not an intermediate in isoflavonoid phytoalexin biosynthesis in alfalfa. Furthermore, protein gel blot analysis and confocal microscopy of a transiently expressed IOMT–green fluorescent protein fusion in alfalfa leaves show that the operationally soluble IOMT localizes to endomembranes after elicitation of the isoflavonoid pathway. We propose that IOMT colocalizes with the endoplasmic reticulum–associated isoflavone synthase cytochrome P450 to ensure rapid B-ring methylation of the unstable 2,4′,7-trihydroxyisoflavanone product of isoflavone synthase, thereby preventing its dehydration to daidzein and subsequent A-ring methylation by free IOMT. In this way, metabolic channeling at the entry point into isoflavonoid phytoalexin biosynthesis protects an unstable intermediate from an unproductive metabolic conversion. PMID:11752378

  18. Enhanced attrition bioreactor for enzyme hydrolysis of cellulosic materials

    DOEpatents

    Scott, Timothy C.; Scott, Charles D.; Faison, Brendlyn D.; Davison, Brian H.; Woodward, Jonathan

    1997-01-01

    A process for converting cellulosic materials, such as waste paper, into fuels and chemicals, such as sugars and ethanol, utilizing enzymatic hydrolysis of the major carbohydrate of paper: cellulose. A waste paper slurry is contacted by cellulase in an agitated hydrolyzer. An attritor and a cellobiase reactor are coupled to the agitated hydrolyzer to improve reaction efficiency. Additionally, microfiltration, ultrafiltration and reverse osmosis steps are included to further increase reaction efficiency. The resulting sugars are converted to a dilute product in a fluidized-bed bioreactor utilizing a biocatalyst, such as microorganisms. The dilute product is then concentrated and purified.

  19. Enhanced attrition bioreactor for enzyme hydrolysis or cellulosic materials

    DOEpatents

    Scott, Timothy C.; Scott, Charles D.; Faison, Brendlyn D.; Davison, Brian H.; Woodward, Jonathan

    1996-01-01

    A process for converting cellulosic materials, such as waste paper, into fuels and chemicals, such as sugars and ethanol, utilizing enzymatic hydrolysis of the major carbohydrate of paper: cellulose. A waste paper slurry is contacted by cellulase in an agitated hydrolyzer. An attritor and a cellobiase reactor are coupled to the agitated hydrolyzer to improve reaction efficiency. Additionally, microfiltration, ultrafiltration and reverse osmosis steps are included to further increase reaction efficiency. The resulting sugars are converted to a dilute product in a fluidized-bed bioreactor utilizing a biocatalyst, such as microorganisms. The dilute product is then concentrated and purified.

  20. Degradation and Volatilization of Chlorofluorocarbons in Contaminated Groundwater Explored by Stable Carbon Isotope Analysis

    NASA Astrophysics Data System (ADS)

    Horst, A.; Lacrampe-Couloume, G.; Sherwood Lollar, B.

    2015-12-01

    Chlorofluorocarbons (CFCs) are ozone depleting compounds whose production was phased out by the regulations of the Montreal Protocol (1987). Accidental release and disposal also led to contamination of groundwater at many locations, however, and this legacy persists. Although very stable, CFCs may degrade via abiotic and biotic pathways. Quantification of the degree of transformation of CFCs has been challenging due to other processes such as dilution, sorption and volatilization. Compound specific stable carbon isotope analysis (CSIA) has been successfully applied for a variety of priority pollutants to distinguish degradation from other processes and to quantify transformation rates. A Purge & Trap - CSIA method developed in our lab was applied to determine the stable carbon isotopic signature of CFCs and HCFCs (hydrochlorofluorocarbons) in groundwater samples from a contaminated site. Preliminary results suggest that degradation of CFCs and HCFCs may result in enriched δ13C values, consistent with fractionation during bond breakage as has been reported for many other hydrocarbon pollutants. The effect of volatile loss during sampling on the isotopic signatures of CFCs was examined in laboratory experiments. Volatilization from pure phase CFCs showed a small inverse isotope effect during open system volatilization, opposite to the normal isotope effect generally observed during biodegradation. For volatilization of CFCs dissolved in water a much smaller isotope effect was observed. An important result from this work is that any volatile loss may introduce only a small change in CFC isotopic signatures in groundwater, and importantly, due to the opposite direction of isotope effects associated with volatilization versus degradation, any effects of volatile loss on the isotopic signatures cannot be confused with transformation of CFCs. At most, volatilization might contribute to a conservative estimate of the extent of degradation.

  1. Assessing connectivity of estuarine fishes based on stable isotope ratio analysis

    NASA Astrophysics Data System (ADS)

    Herzka, Sharon Z.

    2005-07-01

    Assessing connectivity is fundamental to understanding the population dynamics of fishes. I propose that isotopic analyses can greatly contribute to studies of connectivity in estuarine fishes due to the high diversity of isotopic signatures found among estuarine habitats and the fact that variations in isotopic composition at the base of a food web are reflected in the tissues of consumers. Isotopic analysis can be used for identifying nursery habitats and estimating their contribution to adult populations. If movement to a new habitat is accompanied by a shift to foods of distinct isotopic composition, recent immigrants and residents can be distinguished based on their isotopic ratios. Movement patterns thus can be reconstructed based on information obtained from individuals. A key consideration is the rate of isotopic turnover, which determines the length of time that an immigrant to a given habitat will be distinguishable from a longtime resident. A literature survey indicated that few studies have measured turnover rates in fishes and that these have focused on larvae and juveniles. These studies reveal that biomass gain is the primary process driving turnover rates, while metabolic turnover is either minimal or undetectable. Using a simple dilution model and biomass-specific growth rates, I estimated that young fishes with fast growth rates will reflect the isotopic composition of a new diet within days or weeks. Older or slower-growing individuals may take years or never fully equilibrate. Future studies should evaluate the factors that influence turnover rates in fishes during various stages of the life cycle and in different tissues, as well as explore the potential for combining stable isotope and otolith microstructure analyses to examine the relationship between demographic parameters, movement and connectivity.

  2. Molecules and elements for quantitative bioanalysis: The allure of using electrospray, MALDI, and ICP mass spectrometry side-by-side.

    PubMed

    Linscheid, Michael W

    2018-03-30

    To understand biological processes, not only reliable identification, but quantification of constituents in biological processes play a pivotal role. This is especially true for the proteome: protein quantification must follow protein identification, since sometimes minute changes in abundance tell the real tale. To obtain quantitative data, many sophisticated strategies using electrospray and MALDI mass spectrometry (MS) have been developed in recent years. All of them have advantages and limitations. Several years ago, we started to work on strategies, which are principally capable to overcome some of these limits. The fundamental idea is to use elemental signals as a measure for quantities. We began by replacing the radioactive 32 P with the "cold" natural 31 P to quantify modified nucleotides and phosphorylated peptides and proteins and later used tagging strategies for quantification of proteins more generally. To do this, we introduced Inductively Coupled Plasma Mass Spectrometry (ICP-MS) into the bioanalytical workflows, allowing not only reliable and sensitive detection but also quantification based on isotope dilution absolute measurements using poly-isotopic elements. The detection capability of ICP-MS becomes particularly attractive with heavy metals. The covalently bound proteins tags developed in our group are based on the well-known DOTA chelate complex (1,4,7,10-tetraazacyclododecane-N,N',N″,N‴-tetraacetic acid) carrying ions of lanthanoides as metal core. In this review, I will outline the development of this mutual assistance between molecular and elemental mass spectrometry and discuss the scope and limitations particularly of peptide and protein quantification. The lanthanoide tags provide low detection limits, but offer multiplexing capabilities due to the number of very similar lanthanoides and their isotopes. With isotope dilution comes previously unknown accuracy. Separation techniques such as electrophoresis and HPLC were used and just slightly adapted workflows, already in use for quantification in bioanalysis. Imaging mass spectrometry (MSI) with MALDI and laser ablation ICP-MS complemented the range of application in recent years. © 2018 Wiley Periodicals, Inc.

  3. Separation of isotopes by cyclical processes

    DOEpatents

    Hamrin, Jr., Charles E.; Weaver, Kenny

    1976-11-02

    Various isotopes of hydrogen are separated by a cyclic sorption process in which a gas stream containing the isotopes is periodically passed through a high pressure column containing a palladium sorbent. A portion of the product from the high pressure column is passed through a second column at lower pressure to act as a purge. Before the sorbent in the high pressure column becomes saturated, the sequence is reversed with the stream flowing through the former low-pressure column now at high pressure, and a portion of the product purging the former high pressure column now at low pressure. The sequence is continued in cyclic manner with the product being enriched in a particular isotope.

  4. Effects of must concentration techniques on wine isotopic parameters.

    PubMed

    Guyon, Francois; Douet, Christine; Colas, Sebastien; Salagoïty, Marie-Hélène; Medina, Bernard

    2006-12-27

    Despite the robustness of isotopic methods applied in the field of wine control, isotopic values can be slightly influenced by enological practices. For this reason, must concentration technique effects on wine isotopic parameters were studied. The two studied concentration techniques were reverse osmosis (RO) and high-vacuum evaporation (HVE). Samples (must and extracted water) have been collected in various French vineyards. Musts were microfermented at the laboratory, and isotope parameters were determined on the obtained wine. Deuterium and carbon-13 isotope ratios were studied on distilled ethanol by nuclear magnetic resonance (NMR) and isotope ratio mass spectrometry (IRMS), respectively. The oxygen-18 ratio was determined on extracted and wine water using IRMS apparatus. The study showed that the RO technique has a very low effect on isotopic parameters, indicating that this concentration technique does not create any isotopic fractionation, neither at sugar level nor at water level. The effect is notable for must submitted to HVE concentration: water evaporation leads to a modification of the oxygen-18 ratio of the must and, as a consequence, ethanol deuterium concentration is also modified.

  5. Identifying apparent local stable isotope equilibrium in a complex non-equilibrium system.

    PubMed

    He, Yuyang; Cao, Xiaobin; Wang, Jianwei; Bao, Huiming

    2018-02-28

    Although being out of equilibrium, biomolecules in organisms have the potential to approach isotope equilibrium locally because enzymatic reactions are intrinsically reversible. A rigorous approach that can describe isotope distribution among biomolecules and their apparent deviation from equilibrium state is lacking, however. Applying the concept of distance matrix in graph theory, we propose that apparent local isotope equilibrium among a subset of biomolecules can be assessed using an apparent fractionation difference (|Δα|) matrix, in which the differences between the observed isotope composition (δ') and the calculated equilibrium fractionation factor (1000lnβ) can be more rigorously evaluated than by using a previous approach for multiple biomolecules. We tested our |Δα| matrix approach by re-analyzing published data of different amino acids (AAs) in potato and in green alga. Our re-analysis shows that biosynthesis pathways could be the reason for an apparently close-to-equilibrium relationship inside AA families in potato leaves. Different biosynthesis/degradation pathways in tubers may have led to the observed isotope distribution difference between potato leaves and tubers. The analysis of data from green algae does not support the conclusion that AAs are further from equilibrium in glucose-cultured green algae than in the autotrophic ones. Application of the |Δα| matrix can help us to locate potential reversible reactions or reaction networks in a complex system such as a metabolic system. The same approach can be broadly applied to all complex systems that have multiple components, e.g. geochemical or atmospheric systems of early Earth or other planets. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Stable Carbon and Nitrogen Isotopes in a Peat Profile Are Influenced by Early Stage Diagenesis and Changes in Atmospheric CO(2) and N Deposition.

    PubMed

    Esmeijer-Liu, Alice J; Kürschner, Wolfram M; Lotter, André F; Verhoeven, Jos T A; Goslar, Tomasz

    2012-06-01

    In this study, we test whether the δ(13)C and δ(15)N in a peat profile are, respectively, linked to the recent dilution of atmospheric δ(13)CO(2) caused by increased fossil fuel combustion and changes in atmospheric δ(15)N deposition. We analysed bulk peat and Sphagnum fuscum branch C and N concentrations and bulk peat, S. fuscum branch and Andromeda polifolia leaf δ(13)C and δ(15)N from a 30-cm hummock-like peat profile from an Aapa mire in northern Finland. Statistically significant correlations were found between the dilution of atmospheric δ(13)CO(2) and bulk peat δ(13)C, as well as between historically increasing wet N deposition and bulk peat δ(15)N. However, these correlations may be affected by early stage kinetic fractionation during decomposition and possibly other processes. We conclude that bulk peat stable carbon and nitrogen isotope ratios may reflect the dilution of atmospheric δ(13)CO(2) and the changes in δ(15)N deposition, but probably also reflect the effects of early stage kinetic fractionation during diagenesis. This needs to be taken into account when interpreting palaeodata. There is a need for further studies of δ(15)N profiles in sufficiently old dated cores from sites with different rates of decomposition: These would facilitate more reliable separation of depositional δ(15)N from patterns caused by other processes. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11270-011-1001-8) contains supplementary material, which is available to authorized users.

  7. Simultaneous Quantification of Free Cholesterol, Cholesteryl Esters, and Triglycerides without Ester Hydrolysis by UHPLC Separation and In-Source Collision Induced Dissociation Coupled MS/MS

    NASA Astrophysics Data System (ADS)

    Gardner, Michael S.; McWilliams, Lisa G.; Jones, Jeffrey I.; Kuklenyik, Zsuzsanna; Pirkle, James L.; Barr, John R.

    2017-08-01

    We demonstrate the application of in-source nitrogen collision-induced dissociation (CID) that eliminates the need for ester hydrolysis before simultaneous analysis of esterified cholesterol (EC) and triglycerides (TG) along with free cholesterol (FC) from human serum, using normal phase liquid chromatography (LC) coupled to atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MS/MS). The analysis requires only 50 μL of 1:100 dilute serum with a high-throughput, precipitation/evaporation/extraction protocol in one pot. Known representative mixtures of EC and TG species were used as calibrators with stable isotope labeled analogs as internal standards. The APCI MS source was operated with nitrogen source gas. Reproducible in-source CID was achieved with the use of optimal cone voltage (declustering potential), generating FC, EC, and TG lipid class-specific precursor fragment ions for multiple reaction monitoring (MRM). Using a representative mixture of purified FC, CE, and TG species as calibrators, the method accuracy was assessed with analysis of five inter-laboratory standardization materials, showing -10% bias for Total-C and -3% for Total-TG. Repeated duplicate analysis of a quality control pool showed intra-day and inter-day variation of 5% and 5.8% for FC, 5.2% and 8.5% for Total-C, and 4.1% and 7.7% for Total-TG. The applicability of the method was demonstrated on 32 serum samples and corresponding lipoprotein sub-fractions collected from normolipidemic, hypercholesterolemic, hypertriglyceridemic, and hyperlipidemic donors. The results show that in-source CID coupled with isotope dilution UHPLC-MS/MS is a viable high precision approach for translational research studies where samples are substantially diluted or the amounts of archived samples are limited. [Figure not available: see fulltext.

  8. Prostate Specific or Enriched Genes as Composite Biomarkers for Prostate Cancer

    DTIC Science & Technology

    2008-02-01

    isotope dilution by comparing to the 13C- or 15N-labeled reference peptides. The MRM method is best practiced utilizing a triple quadrupole mass...specific, androgen- regulated gene. Here, we evaluate its utility as a prostate cancer tissue marker for diagnosis and prognostic evaluation. Experimental...prevalence of adverse prognostic factors such as capsular penetration, seminal vesicle invasion, and positive surgical margins is rather high compared with

  9. High Throughput Determination of Tetramine in Drinking ...

    EPA Pesticide Factsheets

    Report The sampling and analytical procedure (SAP) presented herein, describes a method for the high throughput determination of tetramethylene disulfotetramine in drinking water by solid phase extraction and isotope dilution gas chromatography/mass spectrometry. This method, which will be included in the SAM, is expected to provide the Water Laboratory Alliance, as part of EPA’s Environmental Response Laboratory Network, with a more reliable and faster means of analyte collection and measurement.

  10. Geochemical aspects of some Japanese lavas.

    NASA Technical Reports Server (NTRS)

    Philpotts, J. A.; Martin, W.; Schnetzler, C. C.

    1971-01-01

    K, Rb, Sr, Ba and rare-earth concentrations in some Japanese lavas have been determined by mass-spectrometric stable-isotope dilution. The samples fall into three rare-earth groups corresponding to tholeiitic, high alumina and alkali basalts. Japanese tholeiites have trace element characteristics similar to those of oceanic ridge tholeiites except for distinctly higher relative concentrations of Ba. Japanese lavas may result from various degrees of partial fusion of amphibole eclogite.

  11. Oxotremorine does not enhance acetylcholine release from rat diaphragm preparations.

    PubMed Central

    Gundersen, C. B.; Jenden, D. J.

    1980-01-01

    We have reinvestigated the dramatic effect of oxotremorine on acetylcholine release from the rat diaphragm reported by Das, Ganguly & Vedasiromoni (1978), using a rigorous gas chromatographic mass spectrometric/isotope dilution method for identification and measurement of acetylcholine and choline. Oxotremorine (10 microM) causes no significant change in the spontaneous or evoked (1 or 10 Hz) release or in the tissue levels of acetylcholine or choline. PMID:7426831

  12. Preparation, certification and validation of a stable solid spike of uranium and plutonium coated with a cellulose derivative for the measurement of uranium and plutonium content in dissolved nuclear fuel by isotope dilution mass spectrometry.

    PubMed

    Surugaya, Naoki; Hiyama, Toshiaki; Verbruggen, André; Wellum, Roger

    2008-02-01

    A stable solid spike for the measurement of uranium and plutonium content in nitric acid solutions of spent nuclear fuel by isotope dilution mass spectrometry has been prepared at the European Commission Institute for Reference Materials and Measurements in Belgium. The spike contains about 50 mg of uranium with a 19.838% (235)U enrichment and 2 mg of plutonium with a 97.766% (239)Pu abundance in each individual ampoule. The dried materials were covered with a thin film of cellulose acetate butyrate as a protective organic stabilizer to resist shocks encountered during transportation and to eliminate flaking-off during long-term storage. It was found that the cellulose acetate butyrate has good characteristics, maintaining a thin film for a long time, but readily dissolving on heating with nitric acid solution. The solid spike containing cellulose acetate butyrate was certified as a reference material with certified quantities: (235)U and (239)Pu amounts and uranium and plutonium amount ratios, and was validated by analyzing spent fuel dissolver solutions of the Tokai reprocessing plant in Japan. This paper describes the preparation, certification and validation of the solid spike coated with a cellulose derivative.

  13. A rapid procedure for the determination of thorium, uranium, cadmium and molybdenum in small sediment samples by inductively coupled plasma-mass spectrometry: Application in Chesapeake Bay

    USGS Publications Warehouse

    Zheng, Yen; Weinman, B.; Cronin, T.; Fleisher, M.Q.; Anderson, Robert F.

    2003-01-01

    This paper describes a rapid procedure that allows precise analysis of Mo, Cd, U and Th in sediment samples as small as 10 mg by using a novel approach that utilizes a "pseudo" isotope dilution for Th and conventional isotope dilution for Mo, Cd and U by ICP-MS. Long-term reproducibility of the method is between 2.5 and 5% with an advantage of rapid analysis on a single digestion of sediment sample and the potential of adding other elements of interest if so desired. Application of this method to two piston cores collected near the mouth of the Patuxent River in Chesapeake Bay showed that the accumulation of authigenic Mo and Cd varied in response to the changing bottom water redox conditions, with anoxia showing consistent oscillations throughout both pre-industrial and industrial times. Accumulation of authigenic U shows consistent oscillations as well, without any apparent increase in productivity related to anoxic trends. Degrees of Mo and Cd enrichment also inversely correlate to halophilic microfaunal assemblages already established as paleoclimate proxies within the bay indicating that bottom water anoxia is driven in part by the amount of freshwater discharge that the area receives. ?? 2002 Elsevier Science Ltd. All rights reserved.

  14. Synthesis and stable isotope dilution assay of ethanethiol and diethyl disulfide in wine using solid phase microextraction. Effect of aging on their levels in wine.

    PubMed

    Belancic Majcenovic, Andrea; Schneider, Rémi; Lepoutre, Jean-Paul; Lempereur, Valérie; Baumes, Raymond

    2002-11-06

    Ethanethiol and diethyl disulfide (DEDS) most often occurred at levels above their olfactive threshold in wines with nauseous sulfur-linked smells. As ethanethiol is very oxidizable and chemically reactive, a stable isotopic dilution analysis of both ethanethiol and its disulfide in wines using solid phase microextraction and GC-MS was developed. The latter involved the determination of the proportion of DEDS formed by oxidation of the thiol during the analysis conditions, which was obtained by the use of two differently labeled disulfide standards. An original synthesis of labeled ethanethiol standards in conditions minimizing oxidation was developed, and the corresponding labeled diethyl disulfides were obtained from these thiols. This analytical method was used to follow the levels of these sulfur compounds during aging in a young red wine spiked with ethanethiol and added with enological tannins, with or without oxygen addition. The total levels of these two sulfur compounds were shown to decrease steadily after 60 days of aging, up to 83%. The effect of oxygen sped this decrease, but the effect of enological tannins was very slight. Residual ethanethiol was detected in its disulfide form from approximately 36% in the nonoxygenated wines to 69% in the oxygenated samples.

  15. Evaluation of the key aroma compounds in beef and pork vegetable gravies a la chef by stable isotope dilution assays and aroma recombination experiments.

    PubMed

    Christlbauer, Monika; Schieberle, Peter

    2011-12-28

    Although the aroma compounds of meat processed as such have been studied previously, data on complete homemade dishes containing beef and pork meat were scarcely studied. Recently, 38 odor-active compounds were characterized in beef and pork vegetable gravies using GC-olfactometry. In the present investigation, the most odor-active compounds were quantitated in a freshly prepared stewed beef vegetable gravy (BVG) as well as a stewed pork vegetable gravy (PVG) by means of stable isotope dilution assays. Calculation of odor activity values (OAVs; ratio of concentration to odor threshold) revealed 3-mercapto-2-methylpentan-1-ol, (E,E)-2,4-decadienal, (E,Z)-2,6-nonadienal, (E)-2-decenal, (E)-2-undecanal, and 3-hydroxy-4,5-dimethyl-2(5H)-furanone as the most potent odorants in both gravies. However, significantly different OAVs were found for 12-methyltridecanal, which was much higher in the BVG, whereas (E,Z)-2,4-decadienal showed a clearly higher OAV in the PVG. Aroma recombination experiments performed on the basis of the actual concentrations of the odorants in both gravies revealed a good similarity of the aromas of both model mixtures containing all odorants with OAVs > 1 with those of the original gravies.

  16. Simultaneous analysis of six aldehyde-DNA adducts in salivary DNA of nonsmokers and smokers using stable isotope dilution liquid chromatography electrospray ionization-tandem mass spectrometry.

    PubMed

    Li, Xiangyu; Liu, Lujuan; Wang, Hongjuan; Chen, Jian; Zhu, Beibei; Chen, Huan; Hou, Hongwei; Hu, Qingyuan

    2017-08-15

    A stable method, using isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS), to simultaneously determine six aldehyde-DNA adducts was developed and applied to the analysis of human salivary DNA samples. The detection limit of these six DNA adducts was in the range of 0.006-0.014ng/mL and that of the quantification limit was 0.017-0.026ng/mL. The intra-day and inter-day precision of all aldehyde-DNA adducts was <10%. The analysis was completed within 25min. Additionally, a noninvasive technique was used to collect the DNA samples from human saliva. The new method was successfully applied for the analysis of salivary DNA of nonsmokers and smokers. Five aldehyde-DNA adducts were detected in both smoker and nonsmoker salivary DNA, while α-Acr-dG was not detected in all the samples. Among these detected DNA adducts, no significant differences were found between smoker and nonsmoker (p>0.05). This may due to the individual detoxifying differences or environmental and endogenous exposure. Our study provides a rapid and selective method to simultaneously detect six aldehyde-DNA adducts and to assess potential DNA damage induced by aldehydes. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Quantification of four major metabolites of embryotoxic N-methyl- and N-ethyl-2-pyrrolidone in human urine by cooled-injection gas chromatography and isotope dilution mass spectrometry.

    PubMed

    Schindler, Birgit K; Koslitz, Stephan; Meier, Swetlana; Belov, Vladimir N; Koch, Holger M; Weiss, Tobias; Brüning, Thomas; Käfferlein, Heiko U

    2012-04-17

    N-Methyl- and N-ethyl-2-pyrollidone (NMP and NEP) are frequently used industrial solvents and were shown to be embryotoxic in animal experiments. We developed a sensitive, specific, and robust analytical method based on cooled-injection (CIS) gas chromatography and isotope dilution mass spectrometry to analyze 5-hydroxy-N-ethyl-2-pyrrolidone (5-HNEP) and 2-hydroxy-N-ethylsuccinimide (2-HESI), two newly identified presumed metabolites of NEP, and their corresponding methyl counterparts (5-HNMP, 2-HMSI) in human urine. The urine was spiked with deuterium-labeled analogues of these metabolites. The analytes were separated from urinary matrix by solid-phase extraction and silylated prior to quantification. Validation of this method was carried out by using both, spiked pooled urine samples and urine samples from 56 individuals of the general population with no known occupational exposure to NMP and NEP. Interday and intraday imprecision was better than 8% for all metabolites, while the limits of detection were between 5 and 20 μg/L depending on the analyte. The high sensitivity of the method enables us to quantify NMP and NEP metabolites at current environmental exposures by human biomonitoring.

  18. An isotope dilution ultra high performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of sugars and humectants in tobacco products.

    PubMed

    Wang, Liqun; Cardenas, Roberto Bravo; Watson, Clifford

    2017-09-08

    CDC's Division of Laboratory Sciences developed and validated a new method for the simultaneous detection and measurement of 11 sugars, alditols and humectants in tobacco products. The method uses isotope dilution ultra high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) and has demonstrated high sensitivity, selectivity, throughput and accuracy, with recoveries ranging from 90% to 113%, limits of detection ranging from 0.0002 to 0.0045μg/mL and coefficients of variation (CV%) ranging from 1.4 to 14%. Calibration curves for all analytes were linear with linearity R 2 values greater than 0.995. Quantification of tobacco components is necessary to characterize tobacco product components and their potential effects on consumer appeal, smoke chemistry and toxicology, and to potentially help distinguish tobacco product categories. The researchers analyzed a variety of tobacco products (e.g., cigarettes, little cigars, cigarillos) using the new method and documented differences in the abundance of selected analytes among product categories. Specifically, differences were detected in levels of selected sugars found in little cigars and cigarettes, which could help address appeal potential and have utility when product category is unknown, unclear, or miscategorized. Copyright © 2017. Published by Elsevier B.V.

  19. Sulfur-based absolute quantification of proteins using isotope dilution inductively coupled plasma mass spectrometry

    NASA Astrophysics Data System (ADS)

    Lee, Hyun-Seok; Heun Kim, Sook; Jeong, Ji-Seon; Lee, Yong-Moon; Yim, Yong-Hyeon

    2015-10-01

    An element-based reductive approach provides an effective means of realizing International System of Units (SI) traceability for high-purity biological standards. Here, we develop an absolute protein quantification method using double isotope dilution (ID) inductively coupled plasma mass spectrometry (ICP-MS) combined with microwave-assisted acid digestion for the first time. We validated the method and applied it to certify the candidate protein certified reference material (CRM) of human growth hormone (hGH). The concentration of hGH was determined by analysing the total amount of sulfur in hGH. Next, the size-exclusion chromatography method was used with ICP-MS to characterize and quantify sulfur-containing impurities. By subtracting the contribution of sulfur-containing impurities from the total sulfur content in the hGH CRM, we obtained a SI-traceable certification value. The quantification result obtained with the present method based on sulfur analysis was in excellent agreement with the result determined via a well-established protein quantification method based on amino acid analysis using conventional acid hydrolysis combined with an ID liquid chromatography-tandem mass spectrometry. The element-based protein quantification method developed here can be generally used for SI-traceable absolute quantification of proteins, especially pure-protein standards.

  20. [Preparation and certification of mussel reference material for organochlorine pesticides and polychlorinated biphenyls using isotope dilution-high resolution mass spectrometry].

    PubMed

    Lu, Xianbo; Chen, Jiping; Wang, Shuqiu; Zou, Lili; Tian, Yuzeng; Ni, Yuwen; Su, Fan

    2012-09-01

    A method for the preparation and certification of the reference material of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in mussel tissue is described. The mussel tissue from Dalian Bay was frozen-dried, comminuted, sieved, homogenized, packaged, and sterilized by 60Co radiation sterilization in turn. The certified values for 18 OCPs and 16 PCBs were determined by high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) using isotope dilution and internal standard quantitation techniques. The certified values were validated and given based on seven accredited laboratories, and these values are traceable to the SI (international system of units) through gravimetrically prepared standards of established purity and measurement intercomparisons. The certified values of PCBs and OCPs in mussel span 4 orders of magnitude with a relative uncertainty of about 10%. This material is a natural biological material with confirmed good homogeneity and stability, and it was approved as the grade "primary reference material" (GBW10069) in June 2012 in China. This reference material provided necessary quality control products for our country to implement the Stockholm Treaty on the monitoring of persistent organic pollutants (POPs). The material is intended to be used for the method validation and quality control in the determination of OCPs and PCBs in biota samples.

  1. Development and co-validation of porcine insulin certified reference material by high-performance liquid chromatography-isotope dilution mass spectrometry.

    PubMed

    Wu, Liqing; Takatsu, Akiko; Park, Sang-Ryoul; Yang, Bin; Yang, Huaxin; Kinumi, Tomoya; Wang, Jing; Bi, Jiaming; Wang, Yang

    2015-04-01

    This article concerns the development and co-validation of a porcine insulin (pINS) certified reference material (CRM) produced by the National Institute of Metrology, People's Republic of China. Each CRM unit contained about 15 mg of purified solid pINS. The moisture content, amount of ignition residue, molecular mass, and purity of the pINS were measured. Both high-performance liquid chromatography-isotope dilution mass spectrometry and a purity deduction method were used to determine the mass fraction of the pINS. Fifteen units were selected to study the between-bottle homogeneity, and no inhomogeneity was observed. A stability study concluded that the CRM was stable for at least 12 months at -20 °C. The certified value of the CRM was (0.892 ± 0.036) g/g. A co-validation of the CRM was performed among Chinese, Japanese, and Korean laboratories under the framework of the Asian Collaboration on Reference Materials. The co-validation results agreed well with the certified value of the CRM. Consequently, the pINS CRM may be used as a calibration material or as a validation standard for pharmaceutical purposes to improve the quality of pharmaceutical products.

  2. Testing sequential extraction methods for the analysis of multiple stable isotope systems from a bone sample

    NASA Astrophysics Data System (ADS)

    Sahlstedt, Elina; Arppe, Laura

    2017-04-01

    Stable isotope composition of bones, analysed either from the mineral phase (hydroxyapatite) or from the organic phase (mainly collagen) carry important climatological and ecological information and are therefore widely used in paleontological and archaeological research. For the analysis of the stable isotope compositions, both of the phases, hydroxyapatite and collagen, have their more or less well established separation and analytical techniques. Recent development in IRMS and wet chemical extraction methods have facilitated the analysis of very small bone fractions (500 μg or less starting material) for PO43-O isotope composition. However, the uniqueness and (pre-) historical value of each archaeological and paleontological finding lead to preciously little material available for stable isotope analyses, encouraging further development of microanalytical methods for the use of stable isotope analyses. Here we present the first results in developing extraction methods for combining collagen C- and N-isotope analyses to PO43-O-isotope analyses from a single bone sample fraction. We tested sequential extraction starting with dilute acid demineralization and collection of both collagen and PO43-fractions, followed by further purification step by H2O2 (PO43-fraction). First results show that bone sample separates as small as 2 mg may be analysed for their δ15N, δ13C and δ18OPO4 values. The method may be incorporated in detailed investigation of sequentially developing skeletal material such as teeth, potentially allowing for the investigation of interannual variability in climatological/environmental signals or investigation of the early life history of an individual.

  3. The development of a new technical platform to measure soil organic nitrogen cycling processes by microbes

    NASA Astrophysics Data System (ADS)

    Hu, Yuntao; Richter, Andreas; Wanek, Wolfgang

    2016-04-01

    Soil organic matter (SOM) decomposition is one of the most important processes of the global nitrogen cycle, having strong implications on soil N availability, terrestrial carbon cycling and soil carbon sequestration. During SOM decomposition low-molecular weight organic nitrogen (LMWON) is released which can be taken up by microbes (and plants). The breakdown of high-molecular weight organic nitrogen (HMWON, e.g. proteins, peptidoglycan, chitin, nucleic acids) represents the bottleneck of soil HMWON decomposition and is performed by extracellular enzymes released mainly by soil microorganisms. Despite that, the current understanding of the controls of these processes is incomplete. The only way to measure gross decomposition rates of these polymers is to use isotope pool dilution (IPD) techniques. In IPD approaches the product pool is isotopically enriched (by e.g. 15N) and the isotope dilution of this pool is measured over time. We have pioneered an IPD for protein and cellulose depolymerization, but IPD approaches for other polymers, specifically for important microbial necromass components such as chitin (fungi) and peptidoglycan (bacteria), or nucleic acids have not yet been developed. Here we present a workflow based on a universally applicable technical platform that allows to estimate the gross depolymerization rate of SOM (HMWON) at the molecular level, using ultra high performance liquid chromatography/high resolution Orbitrap mass spectrometry (UPLC/HRMS) combined with IPD techniques. The necessary isotopically labeled organic polymers (chitin, peptidoglycan and others) are extracted from laboratory bacterial and fungal cultures grown in fully isotopically labeled nutrient media (15N, 13C or both). A purification scheme for the different polymers is currently established. Labeled potential decomposition products (e.g. amino sugars and muropeptides from peptidoglycan, amino sugars and chitooligosaccharides from chitin, nucleotides and nucleosides from nucleic acids) are prepared by enzymatic and/or acid digestion of the polymers. Different UPLC separation columns (Hypercarb, HiliC and C18) make it possible to separate more than 100 related monomers and oligomers produced during polymer decomposition, a prerequisite for analyzing the concentrations and isotope kinetics of decomposition products in complex soil samples. The benchtop Orbitrap mass analyzer has a nominal mass resolving power of 100,000 (FWHM at m/z 200), which enables us to separate compounds that are 13C- and 15N-labelled (mass difference: 0.00632) in the same compound, allowing tracing carbon and nitrogen isotopes in the same compound in IPD experiments. With the accurate masses, retention times and the isotopic pattern we can quantify and qualify the target decomposition products and their isotope kinetics during soil incubation experiments. This will enable us to estimate in situ decomposition rates of the major organic nitrogen polymers in soils, allowing new insights into the major controls of the most important step in soil organic nitrogen recycling.

  4. Kinetic fractionation of stable nitrogen isotopes during amino acid transamination

    NASA Astrophysics Data System (ADS)

    Macko, Stephen A.; Estep, Marilyn L. Fogel; Engel, Michael H.; Hare, P. E.

    1986-10-01

    This study evaluates a kinetic isotope effect involving 15N, during the transamination reactions catalyzed by glutamic oxalacetic transaminase. During the transfer of amino nitrogen from glutamic acid to oxaloacetate to form aspartic acid, 14NH 2 reacted 1.0083 times faster than 14NH 2. In the reverse reaction transferring NH 2 from aspartic acid to α-ketoglutarate, 14NH 2 was incorporated 1.0017 times faster than 15NH 2. Knowledge of the magnitude and sign of these isotope effects will be useful in the interpretation of the distribution of 15N in biological and geochemical systems.

  5. Contrasting dual (C, Cl) isotope fractionation offers potential to distinguish reductive chloroethene transformation from breakdown by permanganate.

    PubMed

    Doğan-Subaşı, Eylem; Elsner, Martin; Qiu, Shiran; Cretnik, Stefan; Atashgahi, Siavash; Shouakar-Stash, Orfan; Boon, Nico; Dejonghe, Winnie; Bastiaens, Leen

    2017-10-15

    cis-1,2-Dichloroethene (cis-DCE) and trichloroethene (TCE) are persistent, toxic and mobile pollutants in groundwater systems. They are both conducive to reductive dehalogenation and to oxidation by permanganate. In this study, the potential of dual element (C, Cl) compound specific isotope analyses (CSIA) for distinguishing between chemical oxidation and anaerobic reductive dechlorination of cis-DCE and TCE was investigated. Well-controlled cis-DCE degradation batch tests gave similar carbon isotope enrichment factors ε C (‰), but starkly contrasting dual element isotope slopes Δδ 13 C/Δδ 37 Cl for permanganate oxidation (ε C =-26‰±6‰, Δδ 13 C/Δδ 37 Cl≈-125±47) compared to reductive dechlorination (ε C =-18‰±4‰, Δδ 13 C/Δδ 37 Cl≈4.5±3.4). The difference can be tracked down to distinctly different chlorine isotope fractionation: an inverse isotope effect during chemical oxidation (ε Cl =+0.2‰±0.1‰) compared to a large normal isotope effect in reductive dechlorination (ε Cl =-3.3‰±0.9‰) (p≪0.05). A similar trend was observed for TCE. The dual isotope approach was evaluated in the field before and up to 443days after a pilot scale permanganate injection in the subsurface. Our study indicates, for the first time, the potential of the dual element isotope approach for distinguishing cis-DCE (and TCE) concentration drops caused by dilution, oxidation by permanganate and reductive dechlorination both at laboratory and field scale. Copyright © 2017. Published by Elsevier B.V.

  6. Rb-Sr, Sm-Nd, K-Ca, O, and H isotopic study of Cretaceous-Tertiary boundary sediments, Caravaca, Spain Evidence for an oceanic impact site

    NASA Technical Reports Server (NTRS)

    Depaolo, D. J.; Kyte, F. T.; Marshall, B. D.; Oneil, J. R.; Smit, J.

    1983-01-01

    The results of isotopic and trace-element-abundance analyses of Ir-enriched Cretaceous-Tertiary-boundary clay sediments from Caravaca, Spain, and of adjacent carbonate and marl layers, are presented. Acetic-acid and HCl leachates and residues were analyzed by isotope dilution to determine K, Rb, Sr, Sm, and Nd concentrations and Sr-87/Sr-86 and Nd-143/Nd-144 ratios. The stable isotope ratios delta-D, delta-(C-13), and delta-(0-18) were also determined. The results are presented in tables and graphs and compared with published data on the Caravaca sediments and on samples from other locations. The boundary clay is found to be distinguished from the adjacent layers by its isotopic ratios and to be of mainly terrestrial, lithospheric (deeper than 3-km) origin. Although submarine-weathering effects are evident and difficult to quantify, the degree of variation in Ni, Ir, Sr, and REE concentrations is considered too large to be attributed to postdepositional processes alone. These findings are seen as evidence for the ocean impact of a large single asteroid producing a worldwide blanket of ejecta, a large injection of water vapor into the atmosphere, and perhaps a gigantic tsunami, at the end of the Cretaceous period.

  7. Novel and non-traditional use of stable isotope tracers to study metal bioavailability from natural particles

    USGS Publications Warehouse

    Croteau, Marie-Noële; Cain, Daniel J.; Fuller, Christopher C.

    2013-01-01

    We devised a novel tracing approach that involves enriching test organisms with a stable metal isotope of low natural abundance prior to characterizing metal bioavailability from natural inorganic particles. In addition to circumventing uncertainties associated with labeling natural particles and distinguishing background metals, the proposed "reverse labeling" technique overcomes many drawbacks inherent to using radioisotope tracers. Specifically, we chronically exposed freshwater snails (Lymnaea stagnalis) to synthetic water spiked with Cu that was 99.4% 65Cu to increase the relative abundance of 65Cu in the snail’s tissues from 32% to >80%. The isotopically enriched snails were then exposed to benthic algae mixed with Cu-bearing Fe–Al particles collected from the Animas River (Colorado), an acid mine drainage impacted river. We used 63Cu to trace Cu uptake from the natural particles and inferred their bioavailability from calculation of Cu assimilation into tissues. Cu assimilation from these particles was 44%, indicating that 44% of the particulate Cu was absorbed by the invertebrate. This demonstrates that inorganic particulate Cu can be bioavailable. The reverse labeling approach shows great potential in various scientific areas such as environmental contamination and nutrition for addressing questions involving uptake of an element that naturally has multiple isotopes.

  8. Physiology of spermatozoa at high dilution rates: the influence of seminal plasma.

    PubMed

    Maxwell, W M; Johnson, L A

    1999-12-01

    Extensive dilution of spermatozoa, as occurs during flow-cytometric sperm sorting, can reduce their motility and viability. These effects may be minimized by the use of appropriate dilution and collection media, containing balanced salts, energy sources, egg yolk and some protein. Dilution and flow-cytometric sorting of spermatozoa, which involves the removal of seminal plasma, also destabilizes sperm membranes leading to functional capacitation. This membrane destabilization renders the spermatozoa immediately capable of fertilization in vitro, or in vivo after deposition close to the site of fertilization, but shortens their lifespan, resulting in premature death if the cells are deposited in the female tract distant from the site of fertilization or are held in vitro at standard storage temperatures. This functional capacitation can be reversed in boar spermatozoa by inclusion of seminal plasma in the medium used to collect the cells from the cell sorter and, consequently, reduces their in vitro fertility. It has yet to be determined whether seminal plasma would have similar effects on flow cytometrically sorted spermatozoa of other species, and what its effects might be on the in vivo fertility of flow sorted boar.

  9. Development and Validation of a Rapid (13)C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices.

    PubMed

    Matsunami, Risë K; Angelides, Kimon; Engler, David A

    2015-05-18

    There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using (13)C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and (13)C6-glucose. The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance. © 2015 Diabetes Technology Society.

  10. Development and Validation of a Rapid 13C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices

    PubMed Central

    Matsunami, Risë K.; Angelides, Kimon; Engler, David A.

    2015-01-01

    Background: There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. Methods: An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using 13C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and 13C6-glucose. Results: The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. Conclusions: The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance. PMID:25986627

  11. Isotope dilution technique for quantitative analysis of endogenous trace element species in biological systems

    NASA Astrophysics Data System (ADS)

    Schaumlöffel, Dirk; Lobinski, Ryszard

    2005-04-01

    The aim of this study was to develop an inductively coupled plasma mass spectrometry (ICPMS) method for the determination of enriched species-specific mercury tracers at ng L-1 levels (ppt) in zooplankton and aquatic samples from biological tracer experiments. Applying a cold vapor sector field ICPMS method a high sensitivity was obtained, i.e., 106 cps for 1 [mu]g L-1 of natural mercury measured on 202Hg+, which in turn enabled the measurement of mercury isotope ratios with a 0.6-1.4%R.S.D. precision for a 50 ng L-1 standard. This method was used to quantify CH3201Hg+ and 200Hg2+ tracers in zooplankton from a biological tracer experiment with the aim of investigating the effects of algal density and zooplankton density on mercury bioaccumulation in zooplankton in a fresh water system. For quantification purposes a known amount of 199Hg+ was added to the zooplankton samples before digestion. The digested samples were analyzed and the resulting ICPMS spectra split into four spectra one for each of the four sources of mercury present in the sample (CH3201Hg+, 200Hg2+, 199Hg2+ and natural mercury) using algebraic de-convoluting. The CH3201Hg+ and 200Hg2+ tracers were quantified using an isotope dilution approach with the added 199Hg+. Detection limits were 0.6 and 0.2 ng L-1 for 200Hg+ and CH3201Hg+, respectively. The coefficient of variation on the tracer determinations was approximately 18% CV estimated from the analysis of real samples with tracer concentrations in the <0.1-100 ng L-1 range. The developed method was successfully applied for the determination of species-specific mercury tracers in zooplankton samples from a biological tracer experiment.

  12. Macronutrient supply, uptake and recycling in the coastal ocean of the west Antarctic Peninsula

    NASA Astrophysics Data System (ADS)

    Henley, Sian F.; Tuerena, Robyn E.; Annett, Amber L.; Fallick, Anthony E.; Meredith, Michael P.; Venables, Hugh J.; Clarke, Andrew; Ganeshram, Raja S.

    2017-05-01

    Nutrient supply, uptake and cycling underpin high primary productivity over the continental shelf of the west Antarctic Peninsula (WAP). Here we use a suite of biogeochemical and isotopic data collected over five years in northern Marguerite Bay to examine these macronutrient dynamics and their controlling biological and physical processes in the WAP coastal ocean. We show pronounced nutrient drawdown over the summer months by primary production which drives a net seasonal nitrate uptake of 1.83 mol N m-2 yr-1, equivalent to net carbon uptake of 146 g C m-2 yr-1. High primary production fuelled primarily by deep-sourced macronutrients is diatom-dominated, but non-siliceous phytoplankton also play a role. Strong nutrient drawdown in the uppermost surface ocean has the potential to cause transient nitrogen limitation before nutrient resupply and/or regeneration. Interannual variability in nutrient utilisation corresponds to winter sea ice duration and the degree of upper ocean mixing, implying susceptibility to physical climate change. The nitrogen isotope composition of nitrate (δ15NNO3) shows a utilisation signal during the growing seasons with a community-level net isotope effect of 4.19 ± 0.29‰. We also observe significant deviation of our data from modelled and observed utilisation trends, and argue that this is driven primarily by water column nitrification and meltwater dilution of surface nitrate. This study is important because it provides a detailed description of the nutrient biogeochemistry underlying high primary productivity at the WAP, and shows that surface ocean nutrient inventories in the Antarctic sea ice zone can be affected by intense recycling in the water column, meltwater dilution and sea ice processes, in addition to utilisation in the upper ocean.

  13. Revisiting N2 fixation in Guerrero Negro intertidal microbial mats with a functional single-cell approach

    PubMed Central

    Woebken, Dagmar; Burow, Luke C; Behnam, Faris; Mayali, Xavier; Schintlmeister, Arno; Fleming, Erich D; Prufert-Bebout, Leslie; Singer, Steven W; Cortés, Alejandro López; Hoehler, Tori M; Pett-Ridge, Jennifer; Spormann, Alfred M; Wagner, Michael; Weber, Peter K; Bebout, Brad M

    2015-01-01

    Photosynthetic microbial mats are complex, stratified ecosystems in which high rates of primary production create a demand for nitrogen, met partially by N2 fixation. Dinitrogenase reductase (nifH) genes and transcripts from Cyanobacteria and heterotrophic bacteria (for example, Deltaproteobacteria) were detected in these mats, yet their contribution to N2 fixation is poorly understood. We used a combined approach of manipulation experiments with inhibitors, nifH sequencing and single-cell isotope analysis to investigate the active diazotrophic community in intertidal microbial mats at Laguna Ojo de Liebre near Guerrero Negro, Mexico. Acetylene reduction assays with specific metabolic inhibitors suggested that both sulfate reducers and members of the Cyanobacteria contributed to N2 fixation, whereas 15N2 tracer experiments at the bulk level only supported a contribution of Cyanobacteria. Cyanobacterial and nifH Cluster III (including deltaproteobacterial sulfate reducers) sequences dominated the nifH gene pool, whereas the nifH transcript pool was dominated by sequences related to Lyngbya spp. Single-cell isotope analysis of 15N2-incubated mat samples via high-resolution secondary ion mass spectrometry (NanoSIMS) revealed that Cyanobacteria were enriched in 15N, with the highest enrichment being detected in Lyngbya spp. filaments (on average 4.4 at% 15N), whereas the Deltaproteobacteria (identified by CARD-FISH) were not significantly enriched. We investigated the potential dilution effect from CARD-FISH on the isotopic composition and concluded that the dilution bias was not substantial enough to influence our conclusions. Our combined data provide evidence that members of the Cyanobacteria, especially Lyngbya spp., actively contributed to N2 fixation in the intertidal mats, whereas support for significant N2 fixation activity of the targeted deltaproteobacterial sulfate reducers could not be found. PMID:25303712

  14. Determination of Mercury Content in a Shallow Firn Core from Summit, Greenland by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

    NASA Technical Reports Server (NTRS)

    Mann, Jacqueline L.; Long, Stephen E.; Shuman, Christopher A.; Kelly, W. Robert

    2003-01-01

    The total mercury Hg content was determined in 6 cm sections of a near-surface 7 m firn core and in surrounding surface snow from Summit, Greenland (elevation: 3238 m, 72.58 N, 38.53 W) in May 2001 by isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICP-MS). The focus of this research was to evaluate the capability of the ID-CV-ICPMS technique for measuring trace levels of Hg typical of polar snow and firn. Highly enriched Hg-201 isotopic spike is added to approximately 10 ml melted core and thoroughly mixed. The Hg(+2) in the sample is reduced on line with tin (II) chloride (SnCl2) and the elemental Hg (Hg(0)) vapor pre-concentrated on to gold gauze using a commercial amalgam system. The Hg is then thermally desorbed and introduced into a quadrupole ICP-MS. The blank corrected Hg concentrations determined for all samples ranged from 0.25 ng/L to 1.74 ng/L (ppt) (average 0.59 ng/L plus or minus 0.28 ng/L) and fall within the range of those previously determined by Boutron et al., 1998 (less than or equal to 0.05 ng/L to 2.0 ng/L) for the Summit site. The average blank value was 0.19 ng/L plus or minus 0.045 ng/L (n=6). The Hg values specifically for the firn core range from 0.25 ng/L to 0.87 ng/L (average 0.51 ng/L plus or minus 0.13 ng/L) and show both values declining with time and larger variability in concentration in the top 1.8 m.

  15. Revisiting N 2 fixation in Guerrero Negro intertidal microbial mats with a functional single-cell approach

    DOE PAGES

    Woebken, Dagmar; Burow, Luke C.; Behnam, Faris; ...

    2014-10-10

    Photosynthetic microbial mats are complex, stratified ecosystems in which high rates of primary production create a demand for nitrogen, met partially by N 2 fixation. Dinitrogenase reductase ( nifH) genes and transcripts from Cyanobacteria and heterotrophic bacteria (for example, Deltaproteobacteria) were detected in these mats, yet their contribution to N 2 fixation is poorly understood. We used a combined approach of manipulation experiments with inhibitors, nifH sequencing and single-cell isotope analysis to investigate the active diazotrophic community in intertidal microbial mats at Laguna Ojo de Liebre near Guerrero Negro, Mexico. Acetylene reduction assays with specific metabolic inhibitors suggested that bothmore » sulfate reducers and members of the Cyanobacteria contributed to N 2 fixation, whereas 15N 2 tracer experiments at the bulk level only supported a contribution of Cyanobacteria. Cyanobacterial and nifH Cluster III (including deltaproteobacterial sulfate reducers) sequences dominated the nifH gene pool, whereas the nifH transcript pool was dominated by sequences related to Lyngbya spp. Single-cell isotope analysis of 15N 2-incubated mat samples via high-resolution secondary ion mass spectrometry (NanoSIMS) revealed that Cyanobacteria were enriched in 15N, with the highest enrichment being detected in Lyngbya spp. filaments (on average 4.4 at% 15N), whereas the Deltaproteobacteria (identified by CARD-FISH) were not significantly enriched. We investigated the potential dilution effect from CARD-FISH on the isotopic composition and concluded that the dilution bias was not substantial enough to influence our conclusions. As a result, our combined data provide evidence that members of the Cyanobacteria, especially Lyngbya spp., actively contributed to N 2 fixation in the intertidal mats, whereas support for significant N 2 fixation activity of the targeted deltaproteobacterial sulfate reducers could not be found.« less

  16. Body composition in Nepalese children using isotope dilution: the production of ethnic-specific calibration equations and an exploration of methodological issues.

    PubMed

    Devakumar, Delan; Grijalva-Eternod, Carlos S; Roberts, Sebastian; Chaube, Shiva Shankar; Saville, Naomi M; Manandhar, Dharma S; Costello, Anthony; Osrin, David; Wells, Jonathan C K

    2015-01-01

    Background. Body composition is important as a marker of both current and future health. Bioelectrical impedance (BIA) is a simple and accurate method for estimating body composition, but requires population-specific calibration equations. Objectives. (1) To generate population specific calibration equations to predict lean mass (LM) from BIA in Nepalese children aged 7-9 years. (2) To explore methodological changes that may extend the range and improve accuracy. Methods. BIA measurements were obtained from 102 Nepalese children (52 girls) using the Tanita BC-418. Isotope dilution with deuterium oxide was used to measure total body water and to estimate LM. Prediction equations for estimating LM from BIA data were developed using linear regression, and estimates were compared with those obtained from the Tanita system. We assessed the effects of flexing the arms of children to extend the range of coverage towards lower weights. We also estimated potential error if the number of children included in the study was reduced. Findings. Prediction equations were generated, incorporating height, impedance index, weight and sex as predictors (R (2) 93%). The Tanita system tended to under-estimate LM, with a mean error of 2.2%, but extending up to 25.8%. Flexing the arms to 90° increased the lower weight range, but produced a small error that was not significant when applied to children <16 kg (p 0.42). Reducing the number of children increased the error at the tails of the weight distribution. Conclusions. Population-specific isotope calibration of BIA for Nepalese children has high accuracy. Arm position is important and can be used to extend the range of low weight covered. Smaller samples reduce resource requirements, but leads to large errors at the tails of the weight distribution.

  17. Rapid quantification of free cholesterol in tears using direct insertion/electron ionization-mass spectrometry.

    PubMed

    Wei, Xiaojia Eric; Korth, John; Brown, Simon H J; Mitchell, Todd W; Truscott, Roger J W; Blanksby, Stephen J; Willcox, Mark D P; Zhao, Zhenjun

    2013-12-09

    To establish a simple and rapid analytical method, based on direct insertion/electron ionization-mass spectrometry (DI/EI-MS), for measuring free cholesterol in tears from humans and rabbits. A stable-isotope dilution protocol employing DI/EI-MS in selected ion monitoring mode was developed and validated. It was used to quantify the free cholesterol content in human and rabbit tear extracts. Tears were collected from adult humans (n = 15) and rabbits (n = 10) and lipids extracted. Screening, full-scan (m/z 40-600) DI/EI-MS analysis of crude tear extracts showed that diagnostic ions located in the mass range m/z 350 to 400 were those derived from free cholesterol, with no contribution from cholesterol esters. DI/EI-MS data acquired using selected ion monitoring (SIM) were analyzed for the abundance ratios of diagnostic ions with their stable isotope-labeled analogues arising from the D6-cholesterol internal standard. Standard curves of good linearity were produced and an on-probe limit of detection of 3 ng (at 3:1 signal to noise) and limit of quantification of 8 ng (at 10:1 signal to noise). The concentration of free cholesterol in human tears was 15 ± 6 μg/g, which was higher than in rabbit tears (10 ± 5 μg/g). A stable-isotope dilution DI/EI-SIM method for free cholesterol quantification without prior chromatographic separation was established. Using this method demonstrated that humans have higher free cholesterol levels in their tears than rabbits. This is in agreement with previous reports. This paper provides a rapid and reliable method to measure free cholesterol in small-volume clinical samples.

  18. An improved reference measurement procedure for triglycerides and total glycerides in human serum by isotope dilution gas chromatography-mass spectrometry.

    PubMed

    Chen, Yizhao; Liu, Qinde; Yong, Sharon; Teo, Hui Ling; Lee, Tong Kooi

    2014-01-20

    Triglycerides are widely tested in clinical laboratories using enzymatic methods for lipid profiling. As enzymatic methods can be affected by interferences from biological samples, this together with the non-specific nature of triglycerides measurement makes it necessary to verify the accuracy of the test results with a reference measurement procedure. Several such measurement procedures had been published. These procedures generally involved lengthy and laborious sample preparation steps. In this paper, an improved reference measurement procedure for triglycerides and total glycerides was reported which simplifies the sample preparation steps and greatly shortens the time taken. The procedure was based on isotope dilution gas chromatography-mass spectrometry (IDGC-MS)with tripalmitin as the calibration standard. Serum samples were first spiked with isotope-labeled tripalmitin. For the measurement of triglycerides, the serum samples were subjected to lipid extraction followed by separation of triglycerides from diglycerides and monoglycerides. Triglycerides were then hydrolyzed to glycerol, derivatized and injected into the GC–MS for quantification. For the measurement of total glycerides, the serum samples were hydrolyzed directly and derivatized before injection into the GC-MS for quantification. All measurement results showed good precision with CV <1%. A certified reference material (CRM) of lipids in frozen human serum was used to verify the accuracy of the measurement. The obtained values for both triglycerides and total glycerides were well within the certified ranges of the CRM, with deviation <0.4% from the certified values. The relative expanded uncertainties were also comparable with the uncertainties associated with the certified values of the CRM. The validated procedure was used in an External Quality Assessment (EQA) Program organized by our laboratory to establish the assigned values for triglycerides and total glycerides.

  19. Cortisol production rates in subjects with suspected Cushing's syndrome: assessment by stable isotope dilution methodology and comparison to other diagnostic methods.

    PubMed

    Samuels, M H; Brandon, D D; Isabelle, L M; Cook, D M; Graham, K E; Purnell, J Q; Loriaux, D L

    2000-01-01

    It can be difficult to establish the diagnosis of Cushing's Syndrome (CS) in patients with mild or nonspecific clinical and biochemical findings, because available diagnostic tests have limited predictive values. We hypothesized that measurement of 24-h cortisol production rates (CPRs) might be a more sensitive indicator of CS in such patients. We measured CPRs in 28 patients with suspected CS (but equivocal biochemical findings) and in 22 healthy control subjects, by infusing tracer amounts of deuterated cortisol, with simultaneous measurements of 24-h urine free cortisol (UFC) levels; and we frequently sampled serum cortisol levels. CPRs were calculated from the ratio of isotopic enrichment to isotopic dilution of cortisol measured by gas chromatography-negative ion chemical ionization mass spectrometry. Nine of the patients proved to have CS by surgery (CS-Yes), whereas 19 patients were determined not to have CS by biochemical testing (CS-No). Mean 24-h UFCs, nocturnal serum cortisol levels, and CPRs were higher in CS-Yes, compared with CS-No and normal subjects. However, one CS-Yes patient had a normal 24-h UFC, two had normal nocturnal serum cortisol levels, and two had normal 24-h CPRs. There was extensive overlap in all of the biochemical parameters between the CS-Yes and the CS-No groups. Thus, measurement of CPR does not seem to offer any diagnostic advantage over available tests for the diagnosis of CS. Patients with proven CS can have normal UFC levels, normal CPRs, or normal nocturnal cortisol levels, whereas patients not thought to have CS may have elevated levels of any one or more these parameters.

  20. High resolution ID-ICP-MS certification of an estuary water reference material (LGC 6016) and analysis of matrix induced polyatomic interferences.

    PubMed

    Evans, P; Fairman, B

    2001-10-01

    Reliable trace metal analysis of environmental samples is dependent upon the availability of high accuracy, matrix reference standards. Here, we present Cd, Cu, Ni, Pb and Zn isotope dilution determination for an estuary water certified reference material (LGC 6016). This work highlights the need for high-accuracy techniques in the development of trace element CRMs rather than conventional inter-laboratory trials. Certification of the estuary water LGC6016 was initially determined from a consensus mean from 14 laboratories but this was found to be unsatisfactory due to the large discrepancies in the reported concentrations. The material was re-analysed using isotope dilution ICP-MS techniques. Pb and Cd were determined using a conventional quadrupole ICP-MS (Elan 5000). Cu, Zn and Ni were determined using a magnetic sector ICP-MS (Finnigan Element), which allowed significant polyatomic interferences to be overcome. Using the magnetic sector instrument, precise mass calibration to within 0.02 amu permitted identification of the interferences. Most interferences derived from the sample matrix. For example, the high Na content causes interferences on 63Cu, due to the formation of 40Ar23Na and 23Na2 16O1H, which in a conventional quadrupole instrument would relate to an erroneous increase in signal intensity by up to 20%. For each analyte a combined uncertainty calculation was performed following the Eurachem/GTAC and ISO guideline. For each element a combined uncertainty of 2-3% was found, which represents a 10-fold improvement compared to certification by inter-laboratory comparison. Analysis of the combined uncertainty budget indicates that the majority of systematic uncertainty derives from the instrumental isotope ratio measurements.

  1. Determination of ultratrace levels of tributyltin in waters by isotope dilution and gas chromatography coupled to tandem mass spectrometry.

    PubMed

    Rodríguez-Cea, Andrés; Rodríguez-González, Pablo; Font Cardona, Nuria; Aranda Mares, José Luís; Ballester Nebot, Salomé; García Alonso, J Ignacio

    2015-12-18

    The current EU legislation lays down the Environmental Quality Standards (EQS) of 45 priority substances in surface water bodies. In particular, the concentration of tributyltin (TBT) must not exceed 0.2ngL(-1) and analytical methodologies with a Limit of Quantification (LOQ) equal or below 0.06ngL(-1) are urged to be developed. This work presents a procedure for the determination of ultratrace levels of TBT in water samples by Isotope Dilution and GC-MS/MS operating in Selected Reaction Monitoring (SRM) mode which meets current EU requirements. The method requires the monitorization of five consecutive transitions (287>175 to 291>179) for the sensitive and selective detection of TBT. The measured isotopic distribution of TBT fragment ions was in agreement with the theoretical values computed by a polynomial expansion algorithm. The combined use of Tandem Mass Spectrometry, a sample volume of 250mL, the preconcentration of 1mL of organic phase to 30μL and an injection volume of 25μL by Programmed Temperature Vaporization provided a LOQ of 0.0426ngL(-1) for TBT (calculated as ten times the standard deviation of nine independent blanks). The recovery for TBT calculated in Milli-Q water at the EQS level was 106.3±4%. A similar procedure was also developed for the quantification of dibutyltin (DBT) and monobutyltin (MBT) in water samples showing satisfactory results. The method was finally implemented in a routine testing laboratory to demonstrate its applicability to real samples obtaining quantitative recoveries for TBT at the EQS level in mineral water, river water and seawater. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. A novel method for the quantitation of gingerol glucuronides in human plasma or urine based on stable isotope dilution assays.

    PubMed

    Schoenknecht, Carola; Andersen, Gaby; Schieberle, Peter

    2016-11-15

    The bio-active compounds of ginger (Zingiber officinale Roscoe), the gingerols, are gaining considerable attention due to their numerous beneficial health effects. In order to elucidate the physiological relevance of the ascribed effects their bioavailability has to be determined taking their metabolization into account. To quantitate in vivo generated [6]-, [8]- and [10]-gingerol glucuronides in human plasma and urine after ginger tea consumption, a simultaneous and direct liquid chromatography-tandem mass spectrometry method based on stable isotope dilution assays was established and validated. The respective references as well as the isotopically labeled substances were synthesized and characterized by mass spectrometry and NMR. Selective isolation of gingerol glucuronides from human plasma and urine by a mixed-phase anion-exchange SPE method led to recovery rates between 80.8 and 98.2%. LC-MS/MS analyses in selected reaction monitoring modus enabled a highly sensitive quantitation of gingerol glucuronides with LoQs between 3.9-9.8nmol/L in plasma and 39.3-161.1nmol/L in urine. The method precision in plasma and urine varied in the range±15%, whereas the intra-day accuracy in plasma and urine showed values between 78 and 122%. The developed method was then applied to a pilot study in which two volunteers consumed one liter ginger tea. Pharmacokinetic parameters like the maximum concentration (c max ), the time to reach c max (t max ), area under the curve (AUC), elimination rate constant (k el ) and elimination half-life (t 1/2 ) were calculated from the concentration-time curve of each gingerol glucuronide. The obtained results will enable more detailed investigation of gingerol glucuronides as bioactives in their physiologically relevant concentrations. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Deuterium and oxygen-18 isotope effects on nucleophilic displacement by water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, J.

    1981-01-01

    Kinetic deuterium isotope effects (k/sub H/sub 2/O//k/sub D/sub 2/O/) have been measured for nucleophilic attack by water at primary alkyl carbon (S-methylthiophenium ion (MeTh+), methyl trifluoromethane-sulfonate (MeOTf), methyl and ethyl perchlorate (MeOClO/sub 3/, EtOClO/sub 3/)) in aprotic solvents (acetonitrile (MeCN) and tetrahydrothiophene-1, 1-dioxide (TMSO/sub 2/; solfolane)) and L/sub 2/O. In L/sub 2/O solvent k/sub H/sub 2/O//k/sub D/sub 2/O/ is significantly greater than unity while it is reduced to near unity in aprotic solvents. The oxygen-18 isotope effect has also been observed to be 1.002 +- 0.004 for the reaction of MeTh/sup +/ with dilute H/sub 2/O in TMSO/sub 2/ atmore » 35/sup 0/C. For the reaction of MeTh/sup +/ and MeOClO/sub 3/ in aprotic solvents the chemical reaction kinetics are discussed.« less

  4. Re-Os Systematics and HSE Distribution in Metal from Ochansk (H4) Chondrite

    NASA Technical Reports Server (NTRS)

    Smoliar, M. I.; Horan, M. F.; Alexander, C. M. OD.; Walker, R. J.

    2003-01-01

    Previous studies of the Re-Os systematics of chondrites have documented considerable variation in the Re/Os ratios of whole rock samples. For some whole rock chondrites, Re-Os systematics display large deviations from the primitive isochron that are considerably larger than deviations in other isotope systems. Possible interpretation of these facts is that the Re-Os system in chondrites is particularly sensitive to post-formation alteration processes, thus providing a useful tool to examine such processes. Significant variations that have been detected in highly siderophile element (HSE) patterns for ordinary chondrites support this conclusion. We report Re-Os isotope data for metal separates from the Ochansk H4 chondrite coupled with abundance data for Ru, Pd, Ir, and Pt, determined in the same samples by isotope dilution. We chose this meteorite mainly because it is an observed fall with minimal signs of weathering, and its low metamorphic grade (H4) and shock stage (S3).

  5. Enhanced attrition bioreactor for enzyme hydrolysis or cellulosic materials

    DOEpatents

    Scott, T.C.; Scott, C.D.; Faison, B.D.; Davison, B.H.; Woodward, J.

    1996-04-16

    A process is described for converting cellulosic materials, such as waste paper, into fuels and chemicals, such as sugars and ethanol, utilizing enzymatic hydrolysis of the major carbohydrate of paper: cellulose. A waste paper slurry is contacted by cellulase in an agitated hydrolyzer. An attritor and a cellobiase reactor are coupled to the agitated hydrolyzer to improve reaction efficiency. Additionally, microfiltration, ultrafiltration and reverse osmosis steps are included to further increase reaction efficiency. The resulting sugars are converted to a dilute product in a fluidized-bed bioreactor utilizing a biocatalyst, such as microorganisms. The dilute product is then concentrated and purified. 1 fig.

  6. Enhanced attrition bioreactor for enzyme hydrolysis of cellulosic materials

    DOEpatents

    Scott, T.C.; Scott, C.D.; Faison, B.D.; Davison, B.H.; Woodward, J.

    1997-06-10

    A process is described for converting cellulosic materials, such as waste paper, into fuels and chemicals, such as sugars and ethanol, utilizing enzymatic hydrolysis of the major carbohydrate of paper: cellulose. A waste paper slurry is contacted by cellulase in an agitated hydrolyzer. An attritor and a cellobiase reactor are coupled to the agitated hydrolyzer to improve reaction efficiency. Additionally, microfiltration, ultrafiltration and reverse osmosis steps are included to further increase reaction efficiency. The resulting sugars are converted to a dilute product in a fluidized-bed bioreactor utilizing a biocatalyst, such as microorganisms. The dilute product is then concentrated and purified. 1 fig.

  7. Complementing approaches to demonstrate chlorinated solvent biodegradation in a complex pollution plume: Mass balance, PCR and compound-specific stable isotope analysis

    NASA Astrophysics Data System (ADS)

    Courbet, Christelle; Rivière, Agnès; Jeannottat, Simon; Rinaldi, Sandro; Hunkeler, Daniel; Bendjoudi, Hocine; de Marsily, Ghislain

    2011-11-01

    This work describes the use of different complementing methods (mass balance, polymerase chain reaction assays and compound-specific stable isotope analysis) to demonstrate the existence and effectiveness of biodegradation of chlorinated solvents in an alluvial aquifer. The solvent-contaminated site is an old chemical factory located in an alluvial plain in France. As most of the chlorinated contaminants currently found in the groundwater at this site were produced by local industries at various times in the past, it is not enough to analyze chlorinated solvent concentrations along a flow path to convincingly demonstrate biodegradation. Moreover, only a few data were initially available to characterize the geochemical conditions at this site, which were apparently complex at the source zone due to (i) the presence of a steady oxygen supply to the groundwater by irrigation canal losses and river infiltration and (ii) an alkaline pH higher than 10 due to former underground lime disposal. A demonstration of the existence of biodegradation processes was however required by the regulatory authority within a timeframe that did not allow a full geochemical characterization of such a complex site. Thus a combination of different fast methods was used to obtain a proof of the biodegradation occurrence. First, a mass balance analysis was performed which revealed the existence of a strong natural attenuation process (biodegradation, volatilization or dilution), despite the huge uncertainty on these calculations. Second, a good agreement was found between carbon isotopic measurements and PCR assays (based on 16S RNA gene sequences and functional genes), which clearly indicated reductive dechlorination of different hydrocarbons (Tetrachloroethene—PCE-, Trichloroethene—TCE-, 1,2- cisDichloroethene— cis-1,2-DCE-, 1,2- transDichloroethene— trans-1,2-DCE-, 1,1-Dichloroethene—1,1-DCE-, and Vinyl Chloride—VC) to ethene. According to these carbon isotope measurements, although TCE biodegradation seems to occur only in the upgradient part of the studied zone, DCE and VC dechlorination (originating from the initial TCE dechlorination) occurs along the entire flowpath. TCE reductase was not detected among the Dehalococcoides bacteria identified by quantitative PCR (qPCR), while DCE and VC reductases were present in the majority of the population. Reverse transcriptase PCR assays (rt-PCR) also indicated that bacteria and their DCE and VC reductases were active. Mass balance calculations showed moreover that 1,1-DCE was the predominant DCE isomer produced by TCE dechlorination in the upgradient part of the site. Consequently, coupling rt-PCR assays with isotope measurements removes the uncertainties inherent in a simple mass balance approach, so that when the three methods are used jointly, they allow the identification and quantification of natural biodegradation, even under apparently complex geochemical and hydraulic conditions.

  8. Fluoride Ion Regeneration of Cyclosarin (Gf) from Minipig Tissue and Fluids Following Whole Body GF Vapor Exposure

    DTIC Science & Technology

    2006-11-01

    Quantitation of organophosphorus nerve agent metabolites in human urine using isotope dilution gas chromatography- tandem mass spectrometry. J. Anal...Recent developments to improve nerve agent biomarker techniques include methods for measuring fluoride regenerated Sarin (GB) in blood and tissue...Our efforts extend the fluoride ion regeneration method to be able to determine cyclosarin (GF) in red blood cells, plasma, and tissue of minipig

  9. GCMS/MS Analyses of Biological Samples in Support of Evaluation of Toxicity Associated with Intravenous Exposure to VX Stereoisomers in Guinea Pigs

    DTIC Science & Technology

    2017-07-01

    14. ABSTRACT: This report documents the results of the gas chromatography–tandem mass spectrometry analyses of blood, tissues, and organs (heart...quantified using chemical ionization mass spectrometry with isotope dilution. 15. SUBJECT TERMS Gas chromatography–tandem mass spectrometry (GC–MS...characterize the pharmacokinetics of the individual stereoisomers and their racemic mixtures. This report details the results of gas chromatography–tandem

  10. Pharmacokinetics and pharmacodynamics of orally administered acetylenic tricyclic bis(cyanoenone), a highly potent Nrf2 activator with a reversible covalent mode of action

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kostov, Rumen V.; Knatko, Elena V.; McLaughlin, Lesley A.

    The acetylenic tricyclic bis(cyanoenone) TBE-31 is a highly potent cysteine targeting compound with a reversible covalent mode of action; its best-characterized target being Kelch-like ECH-associated protein-1 (Keap1), the cellular sensor for oxidants and electrophiles. TBE-31 reacts with cysteines of Keap1, impairing its ability to target nuclear factor-erythroid 2 p45-related factor 2 (Nrf2) for degradation. Consequently, Nrf2 accumulates and orchestrates cytoprotective gene expression. In this study we investigated the pharmacokinetic and pharmacodynamic properties of TBE-31 in C57BL/6 mice. After a single oral dose of 10 μmol/kg (∼200 nmol/animal), the concentration of TBE-31 in blood exhibited two peaks, at 22.3 nM and at 15.5 nM, 40 minmore » and 4 h after dosing, respectively, as determined by a quantitative stable isotope dilution LC-MS/MS method. The AUC{sub 0–24h} was 195.5 h/nmol/l, the terminal elimination half-life was 10.2 h, and the k{sub el} was 0.068 h{sup −1}. To assess the pharmacodynamics of Nrf2 activation by TBE-31, we determined the enzyme activity of its prototypic target, NAD(P)H:quinone oxidoreductase 1 (NQO1) and found it elevated by 2.4- and 1.5-fold in liver and heart, respectively. Continuous feeding for 18 days with diet delivering the same daily doses of TBE-31 under conditions of concurrent treatment with the immunosuppressive agent azathioprine had a similar effect on Nrf2 activation without any indications of toxicity. Together with previous reports showing the cytoprotective effects of TBE-31 in animal models of carcinogenesis, our results demonstrate the high potency, efficacy and suitability for chronic administration of cysteine targeting reversible covalent drugs. - Highlights: • TBE-31 is a cysteine targeting compound with a reversible covalent mode of action. • After a single oral dose, the blood concentration of TBE-31 exhibits two peaks. • Oral TBE-31 is a potent activator of Nrf2-dependent enzymes in multiple organs. • Chronic dietary administration of TBE-31 at doses that show efficacy is not toxic.« less

  11. Isotopic tracking of Hanford 300 area derived uranium in the Columbia River.

    PubMed

    Christensen, John N; Dresel, P Evan; Conrad, Mark E; Patton, Gregory W; DePaolo, Donald J

    2010-12-01

    Our objectives in this study are to quantify the discharge rate of uranium (U) to the Columbia River from the Hanford Site's 300 Area and to follow that U downriver to constrain its fate. Uranium from the Hanford Site has variable isotopic composition due to nuclear industrial processes carried out at the site. This characteristic makes it possible to use high-precision isotopic measurements of U in environmental samples to identify even trace levels of contaminant U, determine its sources, and estimate discharge rates. Our data on river water samples indicate that as much as 3.2 kg/day can enter the Columbia River from the 300 Area, which is only a small fraction of the total load of dissolved natural background U carried by the Columbia River. This very low level of Hanford-derived U can be discerned, despite dilution to <1% of natural background U, 400 km downstream from the Hanford Site. These results indicate that isotopic methods can allow the amounts of U from the 300 Area of the Hanford Site entering the Columbia River to be measured accurately to ascertain whether they are an environmental concern or insignificant relative to natural uranium background in the Columbia River.

  12. Production of stable isotope-labeled acyl-coenzyme A thioesters by yeast stable isotope labeling by essential nutrients in cell culture

    PubMed Central

    Snyder, Nathaniel W.; Tombline, Gregory; Worth, Andrew J.; Parry, Robert C.; Silvers, Jacob A.; Gillespie, Kevin P.; Basu, Sankha S.; Millen, Jonathan; Goldfarb, David S.; Blair, Ian A.

    2015-01-01

    Acyl-coenzyme A (CoA) thioesters are key metabolites in numerous anabolic and catabolic pathways, including fatty acid biosynthesis and β-oxidation, the Krebs cycle, and cholesterol and isoprenoid biosynthesis. Stable isotope dilution-based methodology is the gold standard for quantitative analyses by mass spectrometry. However, chemical synthesis of families of stable isotope labeled metabolites such as acyl-coenzyme A thioesters is impractical. Previously, we biosynthetically generated a library of stable isotope internal standard analogs of acyl-CoA thioesters by exploiting the essential requirement in mammals and insects for pantothenic acid (vitamin B5) as a metabolic precursor for the CoA backbone. By replacing pantothenic acid in the cell media with commercially available [13C3 15N1]-pantothenic acid, mammalian cells exclusively incorporated [13C3 15N1]-pantothenate into the biosynthesis of acyl-CoA and acyl-CoA thioesters. We have now developed a much more efficient method for generating stable isotope labeled CoA and acyl-CoAs from [13C3 15N1]-pantothenate using Stable Isotope Labeling by Essential nutrients in Cell culture (SILEC) in Pan6 deficient yeast cells. Efficiency and consistency of labeling were also increased, likely due to the stringently defined and reproducible conditions used for yeast culture. The yeast SILEC method greatly enhances the ease of use and accessibility of labeled CoA thioesters and also provides proof-of-concept for generating other labeled metabolites in yeast mutants. PMID:25572876

  13. Continual in situ monitoring of pore water stable isotopes in the subsurface

    NASA Astrophysics Data System (ADS)

    Volkmann, T. H. M.; Weiler, M.

    2014-05-01

    Stable isotope signatures provide an integral fingerprint of origin, flow paths, transport processes, and residence times of water in the environment. However, the full potential of stable isotopes to quantitatively characterize subsurface water dynamics is yet unfolded due to the difficulty in obtaining extensive, detailed, and repeated measurements of pore water in the unsaturated and saturated zone. This paper presents a functional and cost-efficient system for non-destructive continual in situ monitoring of pore water stable isotope signatures with high resolution. Automatic controllable valve arrays are used to continuously extract diluted water vapor in soil air via a branching network of small microporous probes into a commercial laser-based isotope analyzer. Normalized liquid-phase isotope signatures are then obtained based on a specific on-site calibration approach along with basic corrections for instrument bias and temperature dependent isotopic fractionation. The system was applied to sample depth profiles on three experimental plots with varied vegetation cover in southwest Germany. Two methods (i.e., based on advective versus diffusive vapor extraction) and two modes of sampling (i.e., using multiple permanently installed probes versus a single repeatedly inserted probe) were tested and compared. The results show that the isotope distribution along natural profiles could be resolved with sufficiently high accuracy and precision at sampling intervals of less than four minutes. The presented in situ approaches may thereby be used interchangeably with each other and with concurrent laboratory-based direct equilibration measurements of destructively collected samples. It is thus found that the introduced sampling techniques provide powerful tools towards a detailed quantitative understanding of dynamic and heterogeneous shallow subsurface and vadose zone processes.

  14. Integrated Extraction Chromatographic Separation of the Lithophile Elements Involved in Long-Lived Radiogenic Isotope Systems (Rb-Sr, U-Th-Pb, Sm-Nd, La-Ce, and Lu-Hf) Useful in Geochemical and Environmental Sciences.

    PubMed

    Pin, Christian; Gannoun, Abdelmouhcine

    2017-02-21

    A fast and efficient sample preparation method in view of isotope ratio measurements is described, allowing the separation of 11 elements involved, either as "parent" or as "daughter" isotopes, in six radiogenic isotope systems used as chronometers and tracers in earth, planetary, and environmental sciences. The protocol is based on small extraction chromatographic columns, used either alone or in tandem, through which a single nitric acid solution is passed, without any intervening evaporation step. The columns use commercially available extraction resins (Sr resin, TRU resin, Ln resin, RE resin, and again Ln resin for isolating Sr and Pb, LREE then La-Ce-Nd-Sm, Lu(Yb), and Hf, Th, and U, respectively) along with an additional, in-house prepared resin for separating Rb. A simplified scheme is proposed for samples requiring the separation of Sr, Pb, Nd, and Hf only. Adverse effects of troublesome major elements (Fe 3+ , Ti) are circumvented by masking with ascorbic acid and hydrofluoric acid, respectively. Typical recoveries in the 85-95% range are achieved, with procedural blanks of 10-100 pg, negligible with regard to the amounts of analytes processed. The fractions separated are suitable for high precision isotope ratio measurements by TIMS or MC-ICP-MS, as demonstrated by the repeat analyses of several international reference materials of basaltic composition for 87 Sr/ 86 Sr, 208,207,206 Pb/ 204 Pb, 143 Nd/ 144 Nd, 176 Hf/ 177 Hf, and 230 Th/ 232 Th. Concentration data could be obtained by spiking and equilibrating the sample with appropriate isotopic tracers before the onset of the separation process and, finally, measuring the isotope ratios modified by the isotope dilution process.

  15. Study of hydrogen bond polarized IR spectra of cinnamic acid crystals

    NASA Astrophysics Data System (ADS)

    Flakus, Henryk T.; Jabłońska, Magdalena

    2004-11-01

    This paper presents the results of investigation of the polarized IR spectra of cinnamic acid and of its deuterium derivative crystals. The spectra were measured by a transmission method, using polarized light, at the room temperature and at 77 K, for two different crystalline faces. Theoretical analysis of the results concerned linear dichroic effects, H/D isotopic and temperature effects, observed in the spectra of the hydrogen and of the deuterium bonds in cinnamic acid crystals, at the frequency ranges of the νO-H and the νO-D bands. The basic crystal spectral properties could be satisfactorily interpreted in a quantitative way for a centrosymmetric cyclic hydrogen bond dimer model. Such a model explains not only a two-branch structure of the νO-H and νO-D bands in crystalline spectra, but also some essential linear dichroic effects in the band frequency ranges, measured for isotopically diluted crystals. Model calculations, performed within the limits of the 'strong-coupling' model, allowed for quantitative interpretation and for understanding of the basic properties of the hydrogen bond IR spectra of cinnamic acid crystals, H/D isotopic, temperature and dichroic effects included. In the scope of our studies the mechanism of H/D isotopic 'self-organization' processes, taking place in the crystal hydrogen bond lattices, was also recognized. It was proved that for isotopically diluted crystalline samples of cinnamic acid, a non-random distribution of protons and deuterons occurs exclusively in the hydrogen bond dimers. Nevertheless, these co-operative interactions between the hydrogen bonds do not involve the adjacent hydrogen bond dimers in each unit cell. The two-branch fine structure pattern of the νO-H and νO-D bands was ascribed to the vibronic mechanism of vibrational dipole selection rule breaking in centrosymmetric hydrogen bond dimers. The observed in the spectra very high intensity of the forbidden transition sub-band in the analyzed νO-H and νO-D bands is a manifestation of an extremely effective symmetry rule breaking mechanism. It correlates with a relatively large excess electron charge on the cinnamic aid dimer carboxyl groups. This effect is a result of a partial withdrawal of the electron charge, from the conjugated π-bond systems of the styryl substituents, by the carboxyl groups. This statement has been supported by ab initio calculations.

  16. Paleohydrology and paleochemistry of Lake Manitoba, Canada: the isotope and ostracode records

    USGS Publications Warehouse

    Last, W.M.; Teller, J.T.; Forester, R.M.

    1994-01-01

    Lake Manitoba, the largest lake in the Prairie region of North America, contains a fine-grained sequence of late Pleistocene and Holocene sediment that documents a complex postglacial history. This record indicates that differential isostatic rebound and changing climate have interacted with varying drainage basin size and hydrologic budget to create significant variations in lake level and limnological conditions. During the initial depositional period in the basin, the Lake Agassiz phase (???12-9 ka), ??18O of ostracodes ranged from -16??? to -5??? (PDB), implying the lake was variously dominated by cold, dilute glacial meltwater and warm to cold, slightly saline water. Candona subtriangulata, which prefers cold, dilute water, dominates the most negative ??18O intervals, when the basin was part of proglacial Lake Agassiz. At times during this early phase, the ??18O of the lake abruptly shifted to higher values; euryhaline taxa such as C. rawsoni or Limnocythere ceriotuberosa, and halobiont taxa such as L. staplini or L. sappaensis are dominant in these intervals. This positive covariance of isotope and ostracode records implies that the lake level episodically fell, isolating the Lake Manitoba basin from the main glacial lake. ??18O values from inorganic endogenic Mg-calcite in the post-Agassiz phase of Lake Manitoba trend from -4??? at 8 ka to -11??? at 4.5 ka. We interpret that this trend indicates a gradually increasing influence of isotopically low (-20??? SMOW) Paleozoic groundwater inflow, although periods of increased evaporation during this time may account for zones of less negative isotopic values. The ??18O of this inorganic calcite abruptly shifts to higher values (-6???) after ???4.5 ka due to the combined effects of increased evaporative enrichment in a closed basin lake and the increased contribution of isotopically high surface water inflow on the hydrologic budget. After ???2 ka, the ??18O of the Mg-calcite fluctuates between -13??? and -7???, implying short-term variability in the lake's hydrologic budget, with values indicating the lake varied from outflow-dominated to evaporation-dominated. The ??13C values of Mg-calcite remain nearly constant from 8 to 4.5 ka and then trend to higher values upward in the section. This pattern suggests primary productivity in the lake was initially constant but gradually increased after 4.5 ka. ?? 1994 Kluwer Academic Publishers.

  17. Validation of uranium determination in urine by ICP-MS.

    PubMed

    Bouvier-Capely, C; Baglan, N; Montègue, A; Ritt, J; Cossonnet, C

    2003-08-01

    A rapid procedure--dilution of urine+ICP-MS measurement--for the determination of uranium in urine was validated. Large ranges of concentration and isotopic composition were studied on urine samples excreted by occupationally exposed workers. The results were consistent with those obtained by fluorimetry and by alpha spectrometry after a purification procedure, two currently used techniques. However, the proposed procedure is limited for determination of the minor isotope 234U. Thus for worker monitoring, the conversion of 234U mass concentration into activity concentration can lead to an erroneous value of the effective dose, in particular for a contamination at very low level with highly enriched uranium. A solution to avoid this hazard is to perform a chemical purification prior to ICP-MS measurement to lower uncertainty and detection limit for 234U.

  18. Fall fertilization enhanced nitrogen storage and translocation in Larix olgensis seedlings

    Treesearch

    Y. Zhu; R. K. Dumroese; G. L. Li; J. R. Pinto; Y. Liu

    2013-01-01

    Fall nutrient loading of deciduous forest nursery seedlings is of special interest because of foliage abscission and varied translocation patterns. For non-deciduous seedlings in the nursery, fall fertilization typically can reverse nutrient dilution and possibly increase nutrient reserves; however, this technique has received little attention with deciduous conifer...

  19. Estimates of Radioxenon Released from Southern Hemisphere Medical isotope Production Facilities Using Measured Air Concentrations and Atmospheric Transport Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eslinger, Paul W.; Friese, Judah I.; Lowrey, Justin D.

    2014-09-01

    Abstract The International Monitoring System (IMS) of the Comprehensive-Nuclear-Test-Ban-Treaty monitors the atmosphere for radioactive xenon leaking from underground nuclear explosions. Emissions from medical isotope production represent a challenging background signal when determining whether measured radioxenon in the atmosphere is associated with a nuclear explosion prohibited by the treaty. The Australian Nuclear Science and Technology Organisation (ANSTO) operates a reactor and medical isotope production facility in Lucas Heights, Australia. This study uses two years of release data from the ANSTO medical isotope production facility and Xe-133 data from three IMS sampling locations to estimate the annual releases of Xe-133 from medicalmore » isotope production facilities in Argentina, South Africa, and Indonesia. Atmospheric dilution factors derived from a global atmospheric transport model were used in an optimization scheme to estimate annual release values by facility. The annual releases of about 6.8×1014 Bq from the ANSTO medical isotope production facility are in good agreement with the sampled concentrations at these three IMS sampling locations. Annual release estimates for the facility in South Africa vary from 1.2×1016 to 2.5×1016 Bq and estimates for the facility in Indonesia vary from 6.1×1013 to 3.6×1014 Bq. Although some releases from the facility in Argentina may reach these IMS sampling locations, the solution to the objective function is insensitive to the magnitude of those releases.« less

  20. An Investigation into the Relationship Between Distillate Yield and Stable Isotope Fractionation

    NASA Astrophysics Data System (ADS)

    Sowers, T.; Wagner, A. J.

    2016-12-01

    Recent breakthroughs in laser spectrometry have allowed for faster, more efficient analyses of stable isotopic ratios in water samples. Commercially available instruments from Los Gatos Research and Picarro allow users to quickly analyze a wide range of samples, from seawater to groundwater, with accurate isotope ratios of D/H to within ± 0.2 ‰ and 18O/16O to within ± 0.03 ‰. While these instruments have increased the efficiency of stable isotope laboratories, they come with some major limitations, such as not being able to analyze hypersaline waters. The Los Gatos Research Liquid Water Isotope Analyzer (LWIA) can accurately and consistently measure the stable isotope ratios in waters with salinities ranging from 0 to 4 grams per liter (0 to 40 parts per thousand). In order to analyze water samples with salinities greater than 4 grams per liter, however, it was necessary to develop a consistent method through which to reduce salinity while causing as little fractionation as possible. Using a consistent distillation method, predictable fractionation of δ 18O and δ 2 H values was found to occur. This fractionation occurs according to a linear relationship with respect to the percent yield of the water in the sample. Using this method, samples with high salinity can be analyzed using laser spectrometry instruments, thereby enabling laboratories with Los Gatos or Picarro instruments to analyze those samples in house without having to dilute them using labor-intensive in-house standards or expensive premade standards.

  1. Manganese Nitride Sorption Joule-Thomson Refrigerator

    NASA Technical Reports Server (NTRS)

    Jones, Jack A.; Phillips, Wayne M.

    1992-01-01

    Proposed sorption refrigeration system of increased power efficiency combines MnxNy sorption refrigeration stage with systems described in "Regenerative Sorption Refrigerator" (NPO-17630). Measured pressure-vs-composition isotherms for reversible chemisorption of N2 in MnxNy suggest feasibility to incorporate MnxNy chemisorption stage in Joule-Thomson cryogenic system. Discovery represents first known reversible nitrogen chemisorption compression system. Has potential in nitrogen-isotope separation, nitrogen purification, or contamination-free nitrogen compression.

  2. Noninvasive measurement of smoking-associated N(3)-ethyladenine and N(7)-ethylguanine in human salivary DNA by stable isotope dilution nanoflow liquid chromatography-nanospray ionization tandem mass spectrometry.

    PubMed

    Chen, Hauh-Jyun Candy; Lin, Chao-Ray

    2014-02-10

    Evidence showed that ethylating agents are contained in cigarette smoke, which damage DNA producing ethylated DNA adducts, including N(3)-ethyladenine (3-EtAde) and N(7)-ethylguanine (7-EtGua). These two ethylpurines can be depurinated spontaneously and be repaired by enzymes and they have been detected in human urine. In this study, a highly specific and sensitive assay based on stable isotope dilution nanoflow liquid chromatography nanospray ionization tandem mass spectrometry (nanoLC-NSI/MS/MS) was used to measure 3-EtAde and 7-EtGua in human salivary DNA. These ethylpurines were released from DNA by neutral thermal hydrolysis and then enriched by a solid-phase extraction column before nanoLC-NSI/MS/MS analysis. The detection limits (S/N≥3) of 3-EtA and 7-EtG were 15 fg (92 amol) and 10 fg (56 amol), respectively, injected on-column. The lower quantification limits of 3-EtAde and 7-EtGua were both 100 fg, i.e. 620 and 560 amol, respectively, corresponding to 9.4 and 8.6 adducts in 10(9) normal nucleotides, respectively, starting with as little as 20 μg of DNA isolated from an average of 3 mL of saliva. The mean (±SD) levels of 3-EtAde in 15 smokers and 15 nonsmokers were 12.6±7.0 and 9.7±5.3 in 10(8) normal nucleotides, respectively, while those of 7-EtGua were 14.1±8.2 and 3.8±2.8 in 10(8) normal nucleotides in smokers and nonsmokers, respectively. Levels of 7-EtGua, but not 3-EtAde, were statistically significantly higher in smokers than in nonsmokers (p<0.0001). Furthermore, salivary 7-EtGua levels are significantly correlated with the number of cigarettes smoked per day as well as with the smoking index. This highly specific and sensitive stable isotope dilution nanoLC-NSI/MS/MS assay might be feasible in measuring 7-EtGua in human salivary DNA as a noninvasive biomarker for DNA damage induced by cigarette smoking. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Developing an Age Model for the Cryogenian: the South China perspective

    NASA Astrophysics Data System (ADS)

    Condon, D. J.; Zhu, M.; Macdonald, F. A.; Tapster, S.

    2014-12-01

    The Neoproterozoic stratigraphic record of South China contains distributed volcanic ash beds, which can be dated and used to provide a backbone for Cryogenian and Ediacaran 'age models'. When integrated with geochemical and paleontological data, both locally and from other regions, these successions inform our understanding of environmental and biological change from these intervals. At present the South China stratigraphy provides the dates that best approximate the termination of the Marinoan glaciation (ca. 635 Ma, U-Pb single zircon isotope dilution1) from a dated volcanic ash bed that occurs in the cap carbonate sequence (Doushantuo Formation) which directly overlies the Nantuo Tillite (Marinoan glaciation equivalent). A number of other ash beds have been documented in both the Nantuo Tillite and throughout the Datangpo Formation (pre-Marinoan non-glacial succession) and have been variably dated using U-Pb microbeam and multi-grain isotope dilution studies2-4. These published data sets have produced dates that have uncertainties on the order of 4 Myr but are built upon single-analyses data points, which have uncertainties on the order of 10 Myr or greater thereby limiting their utility for assessing temporal relationship with other dated section. We present new U-Pb single zircon isotope dilution geochronology data from a suite of samples from the Datangpo, Nantuo and Doushantuo Formations. New dates from the base of the Datangpo Formation confirm a ca. 660 Ma end to the Sturtian glacial epoch, which is represented by underlying glacial deposits. Additional dates from ash beds from the Datangpo Formation and the lower Nantuo Tillite will refine the duration of the Cryogenian non-glacial interlude and Marinoan glaciation as recorded in South China. Combined with published data from Namibia, Australia and Canada, these new data will permit the development of a more highly resolved age model for the Cryogenian, enabling estimation of duration and synchronicity of proxy records. They will also provide further tests and input data for numerical models that seek to simulate Cryogenian climate drivers and responses. 1. D. Condon et al., (2005) Science308, 95; 2. C. M. Zhou et al., (2004) Geology32, 437; 3. S. Zhang, et al., (2008) Terra Nova20, 289; 4. S. Zhang et al., (2005) Geology 33, 473

  4. Reversible and irreversible heat transfer by radiation

    NASA Astrophysics Data System (ADS)

    del Río, Fernando; de la Selva, Sara María Teresa

    2015-05-01

    The theme of heat transfer by radiation is absent from most textbooks on thermodynamics, and its treatment in the applied literature presents some basic discrepancies concerning the validity of the Clausius relation between the quantity of heat exchanged, δ Q, and the accompanying entropy change, dS. We review the reversible and irreversible heat transfers by radiation to clarify the validity of the Clausius relation, and we show that in both cases, the Clausius relation is obeyed, as it should be. We also deal with radiation diluted by the presence of matter, introducing a dilution coefficient, ϕ, and an irreversibility factor, χ (φ ). This treatment requires the use of the correct relation between energy and heat fluxes, the spectral fluxes of energy and entropy, and Planck’s equation for the entropy of monochromatic radiation. For the irreversible case of diluted radiation, we recover the ratio between the fluxes of heat and entropy that agree with Clausius’ inequality, including an irreversibility factor, (4/3)χ (φ ). An improved modification for the explicit function χ (φ ) is given. As an illustration, the fluxes of energy and entropy from the Sun to the Earth are obtained. We also calculate the fluxes re-emitted by the Earth, taking into account the greenhouse effect. We find the value of 1.258 W{{m}-2}{{K}-1} for the re-emitted entropy flux after the radiation has been thermalized, which is much larger than the incident flux, in agreement with other authors.

  5. Small Barriers Trigger Liftoff of Unconfined Dilute Heated Laboratory Density Currents

    NASA Astrophysics Data System (ADS)

    Fauria, K.; Andrews, B. J.; Manga, M.

    2015-12-01

    Dilute pyroclastic density currents (PDCs) are hot, turbulent, particle-laden flows that propagate because they are denser than air. PDCs can traverse tens to hundreds of kilometers and surmount ridges 100s of m tall, yet the effects of complex topography on PDC liftoff and runout distance are uncertain. Here we used scaled laboratory experiments to explore how barriers affect dilute density current dynamics and the occurrence of liftoff. We created dilute density currents by heating and suspending 20 μm diameter talc in air in an 8.5 x 6.1 x 2.6 m tank. We scaled the currents with respect to Froude, densimetric and thermal Richardson, particle Stokes and Settling numbers such that they were dynamically similar to natural PDCs. While currents were fully turbulent, their Reynolds numbers were not as high as those for natural PDCs. We performed the first set of experiments in a laterally unconfined volume, used laser sheets to illuminate the currents, measured bulk sedimentation rates down the current centerlines, and positioned four to twenty-four cm tall ridge-like barriers in the path of the currents. We found that relatively small barriers (~ half the current height) caused PDC liftoff. By comparison, conservation of kinetic and potential energy predicts that incompressible density currents are able to surmount barriers twice their height. Furthermore, we observed increased sedimentation immediately upstream of barriers and conclude that small barriers initiated buoyancy reversal through a combination of increased air entrainment and sedimentation. We conducted a second set of experiments with the same thermal scaling and mass flux rates but where the currents were laterally confined within a 0.6 m wide channel. We found that small barriers also triggered liftoff of confined currents, but that the body of these currents reattached after liftoff. Those results suggest that lateral confinement inhibits buoyancy reversal by limiting the surface area of the current-air interface and air entrainment. Real dilute PDCs that originate in confined valleys may therefore have different fates and longer runout distances than those on unconfined planes.

  6. Improved Stable Isotope Dilution Assay for Dietary Folates Using LC-MS/MS and Its Application to Strawberries

    PubMed Central

    Striegel, Lisa; Chebib, Soraya; Netzel, Michael E.; Rychlik, Michael

    2018-01-01

    Folates play an important role in the human body and a deficiency of this vitamin can cause several diseases. Therefore, a reliable analytical method is crucial for the determination of folate vitamers in strawberries and other dietary folate sources. A stable isotope dilution LC-MS/MS method for analyzing folates in food was developed and validated. The folate vitamers Pteroylmonoglutamic acid, tetrahydrofolate, 5-methyltetrahydrofolate, and 5-formyltetrahydrofolate were quantified using 13C-labeled internal standards. Validation of the assay was accomplished by determining linearity, precision, recovery, limit of detection, and limit of quantification and revealed to be a precise, sensitive, and accurate method to determine folate vitamers. Strawberries are worldwide consumed and known to be a good dietary source of nutritive compounds. Using this method, folate concentrations in selected commercial strawberry cultivars and experimental breeding lines grown in Germany and Australia were investigated. Total folates varied from 59 to 153 μg/100 g on fresh weight basis. Furthermore, folate content after lyophilizing or freezing did not show any significant differences compared to fresh strawberries. However, significant losses of total folates in pureed strawberries could be observed after 5 days of storage with only 16% of the original concentration retained. In summary, some of the investigated strawberry cultivars/breeding lines can be considered as rich dietary sources of natural folates. PMID:29468149

  7. Analysis of acrylamide in coffee and cocoa by isotope dilution liquid chromatography-tandem mass spectrometry.

    PubMed

    Aguas, Patricia C; Fitzhenry, Matthew J; Giannikopoulos, Georgina; Varelis, Peter

    2006-08-01

    An accurate and precise method for the quantification of acrylamide using stable isotope dilution liquid chromatography-tandem mass spectrometry was developed and used to measure acrylamide in coffee and cocoa samples. The sample preparation involved extraction of the analyte and its internal standard, 13C3-acrylamide, into water and subsequent defatting of the aqueous extract with dichloromethane. An aliquot of the resulting aqueous extract was then azeotropically dried under reduced pressure and subsequently purified using an aminopropyl-bonded silica cartridge. The purified extracts were then chromatographed on a 5-microm 2.1 x 150 mm Hypercarb column, the effluent of which was monitored for the analyte and its internal standard using positive-ion APCI-selected reaction monitoring. The intra-laboratory reproducibility of the method, expressed as a relative coefficient of variation (%, n=5), was determined at four levels of concentration (12.3, 42.3, 139.3 and 464.8 microg kg(-1)) and was found to vary between 0.6-2.5%. The accuracy of the method was assessed using a reference sample of coffee. The average result obtained using our method differed from the assigned value of the reference material by less than 1%. An analysis of a cocoa sample revealed that the method is capable of precisely estimating acrylamide in challenging matrices down to a level of at least 12.3 microg kg(-1).

  8. Use of recombinantly produced 15N3-labelled nicotianamine for fast and sensitive stable isotope dilution ultra-performance liquid chromatography/electrospray ionization time-of-flight mass spectrometry.

    PubMed

    Schmidt, Holger; Böttcher, Christoph; Trampczynska, Aleksandra; Clemens, Stephan

    2011-01-01

    Nicotianamine (NA) is an important metal chelator, implicated in the intra- and intercellular trafficking of several transition metal ions in plants. To decipher its roles in physiological processes such as micronutrient acquisition, distribution or storage, fast and sensitive analytical techniques for quantification of this non-proteinogenic amino acid will be required. The use of a recombinant Schizosaccharomyces pombe strain expressing a nicotianamine synthase (NAS) gene allowed for the production of [(15)N(3)]-NA, which was enriched from cell extracts through cation exchange and used for stable isotope dilution analysis of NA. Such an approach should be widely applicable to important bioanalytes that are difficult to synthesize. The analytical procedure comprises mild aqueous extraction and rapid Fmoc derivatization, followed by fast separation using ultra-performance liquid chromatography (UPLC) and sensitive detection by positive ion electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS) with a chromatographic cycle time of only 8 min. Derivatization was optimized with respect to incubation time and species suitable for quantification. The limit of detection was 0.14 to 0.23 pmol in biological matrices with the response being linear up to 42 pmol. Recovery rates were between 83% and 104% in various biological matrices including fission yeast cells, fungal mycelium, plant leaves and roots.

  9. Determination of bisphenol A, triclosan and their metabolites in human urine using isotope-dilution liquid chromatography-tandem mass spectrometry.

    PubMed

    Provencher, Gilles; Bérubé, René; Dumas, Pierre; Bienvenu, Jean-François; Gaudreau, Eric; Bélanger, Patrick; Ayotte, Pierre

    2014-06-27

    Bisphenol A (BPA) and triclosan (TCS) are ubiquitous environmental phenols exhibiting endocrine disrupting activities that may be involved in various health disorders in humans. There is a need to measure separately free forms and conjugated metabolites because only the former are biologically active. We have developed sensitive methods using isotope-dilution liquid chromatography-tandem mass spectrometry for individual measurements of free BPA and TCS as well as their metabolites, BPA glucuronide (BPAG), BPA monosulfate (BPAS), BPA disulfate (BPADS), TCS glucuronide (TCSG) and TCS sulfate (TCSS) in urine. Comparative analyses of urine samples from 46 volunteers living in the Quebec City area using the new methods and a GC-MS/MS method previously used in our laboratory revealed very strong correlations for total BPA (Spearman's rs=0.862, p<0.0001) and total TCS concentrations (rs=0.942, p<0.0001). Glucuronide metabolites were the most abundant BPA and TCS species in urine samples (>94% of total urinary concentrations). Unconjugated TCS concentrations represented a small proportion of total TCS species (median=1.6%) but its concentration was likely underestimated due to losses by adsorption to the surface of polypropylene tubes used for sample storage. To our knowledge, we are the first to report levels of free, sulfated and glucuronidated TCS levels in human urine. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Simultaneous determination of nine neonicotinoids in human urine using isotope-dilution ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Zhang, Quan; Wang, Ximing; Li, Zhe; Jin, Hangbiao; Lu, Zhengbiao; Yu, Chang; Huang, Yu-Fang; Zhao, Meirong

    2018-05-14

    Neonicotinoids (neonics), a class of systemic insecticides, have been frequently detected in pollen, vegetables, and fruits. Recently, an increasing concern has been aroused for human exposure to neonics. However, biological monitoring for quantifying body burden of neonics has rarely been reported. In this study, we developed an isotope-dilution ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) method to simultaneously quantify nine neonics, including acetamiprid (ACE), thiamethoxam (THIAM), imidacloprid (IMIP), clothianidin (CLO), flonicamid (FLO), thiacloprid (THIAC), dinotefuran (DIN), nitenpyram (NIT), and imidaclothiz (IMIT) in urine. The limits of quantification were 0.1 μg/L for ACE, FLO, DIN, NIT and IMIT, and 0.2 μg/L for THIAM, IMIP, CLO, and THIAC. The overall recoveries were 80.8-103%, 81.5-91.7% and 83.0-92.3% for QA/QC samples fortifying at 1, 25, and 100 μg/L levels, respectively. UPLC/MS/MS method was used to analyze urine samples obtained from 10 children in Hangzhou, China. The detection frequencies were 80% for ACE and IMIP, 70% for THIAM and CLO, 20% for DIN and IMIT and 10% for THIAC. FLO and NIT were not detected in those urine samples. The data provided here will be helpful for conducting biological monitoring of neonics exposure in the future. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Determination of cadmium in grains by isotope dilution ICP-MS and coprecipitation using sample constituents as carrier precipitants.

    PubMed

    Inagaki, Kazumi; Narukawa, Tomohiro; Yarita, Takashi; Takatsu, Akiko; Okamoto, Kensaku; Chiba, Koichi

    2007-10-01

    A coprecipitation method using sample constituents as carrier precipitants was developed that can remove molybdenum, which interferes with the determination of cadmium in grain samples via isotope dilution inductively coupled plasma mass spectrometry (ID-ICPMS). Samples were digested with HNO3, HF, and HClO4, and then purified 6 M sodium hydroxide solution was added to generate colloidal hydrolysis compounds, mainly magnesium hydroxide. Cadmium can be effectively separated from molybdenum because the cadmium forms hydroxides and adsorbs onto and/or is occluded in the colloid, while the molybdenum does not form hydroxides or adsorb onto the hydrolysis colloid. The colloid was separated by centrifugation and then dissolved with 0.2 M HNO3 solution to recover the cadmium. The recovery of Cd achieved using the coprecipitation was >97%, and the removal efficiency of Mo was approximately 99.9%. An extremely low procedural blank (below the detection limit of ICPMS) was achieved by purifying the 6 M sodium hydroxide solution via Mg coprecipitation using Mg(NO3)2 solution. The proposed method was applied to two certified reference materials (NIST SRM 1567a wheat flour and SRM 1568a rice flour) and CCQM-P64 soybean powder. Good analytical results with small uncertainties were obtained for all samples. This method is simple and reliable for the determination of Cd in grain samples by ID-ICPMS.

  12. Quantitative determination of four nitrofuran metabolites in meat by isotope dilution liquid chromatography-electrospray ionisation-tandem mass spectrometry.

    PubMed

    Mottier, Pascal; Khong, Seu-Ping; Gremaud, Eric; Richoz, Janique; Delatour, Thierry; Goldmann, Till; Guy, Philippe A

    2005-03-04

    A confirmatory method based on isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed for the low-level determination of residues of four nitrofuran veterinary drugs in meat, e.g., furazolidone, furaltadone, nitrofurantoin, and nitrofurazone. The procedure entails an acid-catalysed release of protein-bound metabolites, followed by their in situ conversion into the 2-nitrobenzaldehyde (NBA) imine-type derivatives. Liquid-liquid extraction and clean-up on a polymeric solid phase extraction cartridge are then performed before LC-MS/MS analysis by positive electrospray ionisation (ESI) applying multiple reaction monitoring of three transition reactions for each compound. Reliable quantitation is obtained by using one deuterated analogue per analyte (d4-NBA derivative) as internal standard (IS). Validation of the method in chicken meat was conducted following the European Union (EU) criteria for the analysis of veterinary drug residues in foods. The decision limits (CCalpha) were 0.11-0.21 microg/kg, and the detection capabilities (CCbeta) 0.19-0.36 microg/kg, thus below the minimum required performance limit (MRPL) set at 1 microg/kg by the EU. The method is robust and suitable for routine quality control operations, and more than 200 sample injections were performed without excessive pollution of the mass spectrometer or loss of LC column performance.

  13. Improved stable isotope dilution assay for dietary folates using LC-MS/MS and its application to strawberries

    NASA Astrophysics Data System (ADS)

    Striegel, Lisa; Chebib, Soraya; Netzel, Michael E.; Rychlik, Michael

    2018-02-01

    Folates play an important role in the human body and a deficiency of this vitamin can cause several diseases. Therefore, a reliable analytical method is crucial for the determination of folate vitamers in strawberries and other dietary folate sources. A stable isotope dilution LC-MS/MS method for analyzing folates in food was developed and validated. The folate vitamers Pteroylmonoglutamic acid, tetrahydrofolate, 5-methyltetrahydrofolate and 5-formyltetrahydrofolate were quantified using 13C-labelled internal standards. Validation of the assay was accomplished by determining linearity, precision, recovery, limit of detection and limit of quantification and revealed to be a precise, sensitive and accurate method to determine folate vitamers. Strawberries are worldwide consumed and known to be a good dietary source of nutritive compounds. Using this method, folate concentrations in selected commercial strawberry cultivars and experimental breeding lines grown in Germany were investigated. Total folates varied from 59 to 153 µg/100 g on fresh weight basis. Furthermore, folate content after lyophilizing or freezing did not show any significant differences compared to fresh strawberries. However, significant losses of total folates in pureed strawberries could be observed after 5 days of storage with only 16 % of the original concentration retained. In summary, some of the investigated strawberry cultivars/breeding lines can be considered as rich dietary sources of natural folates.

  14. Simultaneous determination of water-soluble vitamins in SRM 1849 Infant/Adult Nutritional Formula powder by liquid chromatography-isotope dilution mass spectrometry.

    PubMed

    Goldschmidt, Robert J; Wolf, Wayne R

    2010-05-01

    Assessing dietary intake of vitamins from all sources, including foods, dietary supplements, and fortified foods, would be aided considerably by having analytical methodologies that are capable of simultaneous determination of several vitamins. Vitamins naturally present in foods may occur in different chemical forms, with levels ranging over several orders of magnitude. Vitamins in dietary supplements and fortified foods, however, are typically added in a single chemical form, and matrix issues are usually not as complex. These sources should thus be relatively amenable to approaches that aim for simultaneous determination of multiple vitamins. Our recent work has focused on development of liquid chromatography (LC)-UV/fluorescence and LC-tandem mass spectrometry methods for the simultaneous determination of water-soluble vitamins (thiamine, niacin, pyridoxine, pantothenic acid, folic acid, biotin, and riboflavin) in dietary supplement tablets and fortified foods, such as formula powders and breakfast cereals. As part of the validation of our methods and collaboration in characterization of a new NIST SRM 1849 Infant/Adult Nutritional Formula powder, we report data on SRM 1849 using isotope dilution mass spectrometric methods. Use of available NIST Standard Reference Materials(R) as test matrices in our method development and validation gives a benchmark for future application of these methods. We compare three chromatographic approaches and provide data on stability of vitamin standard solutions for LC-based multiple vitamin determinations.

  15. Body Composition of Bangladeshi Children: Comparison and Development of Leg-to-Leg Bioelectrical Impedance Equation

    PubMed Central

    Khan, I.; Hawlader, Sophie Mohammad Delwer Hossain; Arifeen, Shams El; Moore, Sophie; Hills, Andrew P.; Wells, Jonathan C.; Persson, Lars-Åke; Kabir, Iqbal

    2012-01-01

    The aim of this study was to investigate the validity of the Tanita TBF 300A leg-to-leg bioimpedance analyzer for estimating fat-free mass (FFM) in Bangladeshi children aged 4-10 years and to develop novel prediction equations for use in this population, using deuterium dilution as the reference method. Two hundred Bangladeshi children were enrolled. The isotope dilution technique with deuterium oxide was used for estimation of total body water (TBW). FFM estimated by Tanita was compared with results of deuterium oxide dilution technique. Novel prediction equations were created for estimating FFM, using linear regression models, fitting child's height and impedance as predictors. There was a significant difference in FFM and percentage of body fat (BF%) between methods (p<0.01), Tanita underestimating TBW in boys (p=0.001) and underestimating BF% in girls (p<0.001). A basic linear regression model with height and impedance explained 83% of the variance in FFM estimated by deuterium oxide dilution technique. The best-fit equation to predict FFM from linear regression modelling was achieved by adding weight, sex, and age to the basic model, bringing the adjusted R2 to 89% (standard error=0.90, p<0.001). These data suggest Tanita analyzer may be a valid field-assessment technique in Bangladeshi children when using population-specific prediction equations, such as the ones developed here. PMID:23082630

  16. Tubulin Dimer Reversible Dissociation

    PubMed Central

    Schuck, Peter; Sackett, Dan L.

    2016-01-01

    Tubulins are evolutionarily conserved proteins that reversibly polymerize and direct intracellular traffic. Of the tubulin family only αβ-tubulin forms stable dimers. We investigated the monomer-dimer equilibrium of rat brain αβ-tubulin using analytical ultracentrifugation and fluorescence anisotropy, observing tubulin in virtually fully monomeric and dimeric states. Monomeric tubulin was stable for a few hours and exchanged into preformed dimers, demonstrating reversibility of dimer dissociation. Global analysis combining sedimentation velocity and fluorescence anisotropy yielded Kd = 84 (54–123) nm. Dimer dissociation kinetics were measured by analyzing the shape of the sedimentation boundary and by the relaxation of fluorescence anisotropy following rapid dilution of labeled tubulin, yielding koff in the range 10−3–10−2 s−1. Thus, tubulin dimers reversibly dissociate with moderately fast kinetics. Monomer-monomer association is much less sensitive than dimer-dimer association to solution changes (GTP/GDP, urea, and trimethylamine oxide). PMID:26934918

  17. Low-temperature, non-stoichiometric oxygen isotope exchange coupled to Fe(II)-goethite interactions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frierdich, Andrew J.; Beard, Brian L.; Rosso, Kevin M.

    2015-07-01

    The oxygen isotope composition of natural iron oxide minerals has been widely used as a paleoclimate proxy. Interpretation of their stable isotope compositions, however, requires accurate knowledge of isotopic fractionation factors and an understanding of their isotopic exchange kinetics, the latter of which informs us how diagenetic processes may alter their isotopic compositions. Prior work has demonstrated that crystalline iron oxides do not significantly exchange oxygen isotopes with pure water at low temperature, which has restricted studies of isotopic fractionation factors to precipitation experiments or theoretical calculations. Using a double three-isotope method (¹⁸O-¹⁷O-¹⁶O and ⁵⁷Fe-⁵⁶Fe-⁵⁴Fe) we compare O and Femore » isotope exchange kinetics, and demonstrate, for the first time, that O isotope exchange between structural O in crystalline goethite and water occurs in the presence of aqueous Fe(II) (Fe(II) aq) at ambient temperature (i.e., 22–50 °C). The three-isotope method was used to extrapolate partial exchange results to infer the equilibrium, mass-dependent isotope fractionations between goethite and water. In addition, this was combined with a reversal approach to equilibrium by reacting goethite in two unique waters that vary in composition by about 16‰ in ¹⁸O/¹⁶O ratios. Our results show that interactions between Fe(II) aq and goethite catalyzes O isotope exchange between the mineral and bulk fluid; no exchange (within error) is observed when goethite is suspended in ¹⁷O-enriched water in the absence of Fe(II) aq. In contrast, Fe(II)-catalyzed O isotope exchange is accompanied by significant changes in ¹⁸O/¹⁶O ratios. Despite significant O exchange, however, we observed disproportionate amounts of Fe versus O exchange, where Fe isotope exchange in goethite was roughly three times that of O. This disparity provides novel insight into the reactivity of oxide minerals in aqueous solutions, but presents a challenge for utilizing such an approach to determine equilibrium isotope fractionation factors. Despite the uncertainty from extrapolation, there is consistency in goethite-water fractionation factors for our reversal approach to equilibrium, with final weighted average fractionation factor values of Δ¹⁸O Gth-wate r = 0.2 (±0.9‰) and 3.0 (±2.5‰) at 22 °C and -1.6 (±0.8‰) and 1.9 (±1.5‰) at 50 °C for micron-sized and nano-particulate goethite, respectively (errors at 2σ level). Reaction of ferrihydrite with Fe(II) aq in two distinct waters resulted in a quantitative conversion to goethite and complete O isotope exchange in each case, and similar fractionation factors were observed for experiments using the two waters. Comparison of our results with previous studies of O isotope fractionation between goethite and water suggests that particle size may be a contributing factor to the disparity among experimental studies.« less

  18. Toward a simple, repeatable, non-destructive approach to measuring stable-isotope ratios of water within tree stems

    NASA Astrophysics Data System (ADS)

    Raulerson, S.; Volkmann, T.; Pangle, L. A.

    2017-12-01

    Traditional methodologies for measuring ratios of stable isotopes within the xylem water of trees involve destructive coring of the stem. A recent approach involves permanently installed probes within the stem, and an on-site assembly of pumps, switching valves, gas lines, and climate-controlled structure for field deployment of a laser spectrometer. The former method limits the possible temporal resolution of sampling, and sample size, while the latter may not be feasible for many research groups. We present results from initial laboratory efforts towards developing a non-destructive, temporally-resolved technique for measuring stable isotope ratios within the xylem flow of trees. Researchers have used direct liquid-vapor equilibration as a method to measure isotope ratios of the water in soil pores. Typically, this is done by placing soil samples in a fixed container, and allowing the liquid water within the soil to come into isotopic equilibrium with the headspace of the container. Water can also be removed via cryogenic distillation or azeotropic distillation, with the resulting liquid tested for isotope ratios. Alternatively, the isotope ratios of the water vapor can be directly measured using a laser-based water vapor isotope analyzer. Well-established fractionation factors and the isotope ratios in the vapor phase are then used to calculate the isotope ratios in the liquid phase. We propose a setup which would install a single, removable chamber onto a tree, where vapor samples could non-destructively and repeatedly be taken. These vapor samples will be injected into a laser-based isotope analyzer by a recirculating gas conveyance system. A major part of what is presented here is in the procedure of taking vapor samples at 100% relative humidity, appropriately diluting them with completely dry N2 calibration gas, and injecting them into the gas conveyance system without inducing fractionation in the process. This methodology will be helpful in making temporally resolved measurements of the stable isotopes in xylem water, using a setup that can be easily repeated by other research groups. The method is anticipated to find broad application in ecohydrological analyses, and in tracer studies aimed at quantifying age distributions of soil water extracted by plant roots.

  19. Energy-efficient membrane separations in the sweetener industry. Final report for Phase I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Babcock, W.C.

    1984-02-14

    The objective of the program is to investigate the use of membrane processes as energy-efficient alternatives to conventional separation processes in current use in the corn sweetener industry. Two applications of membranes were studied during the program: (1) the concentration of corn steep water by reverse osmosis; and (2) the concentration of dilute wastes called sweetwater with a combination of reverse osmosis and a process known as countercurrent reverse osmosis. Laboratory experiments were conducted for both applications, and the results were used to conduct technical and economic analyses of the process. It was determined that the concentration of steep watermore » by reverse osmosis plus triple-effect evaporation offers savings of a factor of 2.5 in capital costs and a factor of 4.5 in operating costs over currently used triple-effect evaporation. In the concentration of sweetwater by reverse osmosis and countercurrent reverse osmosis, capital costs would be about the same as those for triple-effect evaporation, but operating costs would be only about one-half those of triple-effect evaporation.« less

  20. Predicting solubilisation features of ternary phase diagrams of fully dilutable lecithin linker microemulsions.

    PubMed

    Nouraei, Mehdi; Acosta, Edgar J

    2017-06-01

    Fully dilutable microemulsions (μEs), used to design self-microemulsifying delivery system (SMEDS), are formulated as concentrate solutions containing oil and surfactants, without water. As water is added to dilute these systems, various μEs are produced (water-swollen reverse micelles, bicontinuous systems, and oil-swollen micelles), without the onset of phase separation. Currently, the formulation dilutable μEs follows a trial and error approach that has had a limited success. The objective of this work is to introduce the use of the hydrophilic-lipophilic-difference (HLD) and net-average-curvature (NAC) frameworks to predict the solubilisation features of ternary phase diagrams of lecithin-linker μEs and the use of these predictions to guide the formulation of dilutable μEs. To this end, the characteristic curvatures (Cc) of soybean lecithin (surfactant), glycerol monooleate (lipophilic linker) and polyglycerol caprylate (hydrophilic linker) and the equivalent alkane carbon number (EACN) of ethyl caprate (oil) were obtained via phase scans with reference surfactant-oil systems. These parameters were then used to calculate the HLD of lecithin-linkers-ethyl caprate microemulsions. The calculated HLDs were able to predict the phase transitions observed in the phase scans. The NAC was then used to fit and predict phase volumes obtained from salinity phase scans, and to predict the solubilisation features of ternary phase diagrams of the lecithin-linker formulations. The HLD-NAC predictions were reasonably accurate, and indicated that the largest region for dilutable μEs was obtained with slightly negative HLD values. The NAC framework also predicted, and explained, the changes in microemulsion properties along dilution lines. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Honey dilution impact on in vitro wound healing: Normoxic and hypoxic condition.

    PubMed

    Chaudhary, Amrita; Bag, Swarnendu; Barui, Ananya; Banerjee, Provas; Chatterjee, Jyotirmoy

    2015-01-01

    Honey is known as a popular healing agent against tropical infections and wounds. However, the effects of honey dilutions on keratinocyte (HaCaT) wound healing under hypoxic condition is still not explored. In this study, we examined whether honey dilution have wound healing potential under hypoxic stress. The antioxidant potential and healing efficacy of honey dilution on in vitro wound of human epidermal keratinocyte (HaCaT cells) under hypoxia (3% O2 ), and normoxia is explored by nitro blue tetrazolium assay. The cell survival % quantified by MTT assay to select four honey dilutions like 10, 1, 0.1, and 0.01 v/v% and the changes in cellular function was observed microscopically. Further, the cell proliferation, migration, cell-cell adhesion, and relevant gene expression were studied by flow cytometry, migration/scratch assay, immunocytochemistry, and reverse transcription-polymerase chain reaction, respectively. The expression pattern of cardinal molecular features viz. E-cadherin, cytoskeletal protein F-actin, p63, and hypoxia marker Hif 1α were examined. Honey dilution in 0.1% v/v combat wound healing limitations in vitro under normoxia and hypoxia (3%). Its wound healing potential was quantified by immunocytochemistry and real-time PCR for the associated molecular features that were responsible for cell proliferation and migration. Our data showed that honey dilution can be effective in hypoxic wound healing. Additionally, it reduced superoxide generation and supplied favorable bioambience for cell proliferation, migration, and differentiation during hypoxic wound healing. These findings may reveal the importance of honey as an alternative and cost effective therapeutic natural product for wound healing in hypoxic condition. © 2015 by the Wound Healing Society.

  2. Isotope Effects and Mechanism of the Asymmetric BOROX Brønsted Acid Catalyzed Aziridination Reaction

    PubMed Central

    Vetticatt, Mathew J.; Desai, Aman A.; Wulff, William D.

    2013-01-01

    The mechanism of the chiral VANOL-BOROX Brønsted acid catalyzed aziridination reaction of imines and ethyldiazoacetate has been studied using a combination of experimental kinetic isotope effects and theoretical calculations. A stepwise mechanism where reversible formation of a diazonium ion intermediate precedes rate-limiting ring-closure to form the cis-aziridine is implicated. A revised model for the origin of enantio- and diastereoselectivity is proposed based on relative energies of the ring closing transition structures. PMID:23687986

  3. Pressure-dependent boron isotopic fractionation observed by column chromatography

    NASA Astrophysics Data System (ADS)

    Musashi, M.; Oi, T.; Matsuo, M.; Nomura, M.

    2007-12-01

    Boron isotopic fractionation factor ( S ) between boron taken up in strongly basic anion exchange resin and boron in aqueous solution was determined by breakthrough column chromatography at 5 and 17 MPa at 25°C, using 0.1 mmol/L boric acid solution as feed solution. The S values obtained were 1.018 and 1.012, respectively, which were smaller than the value reported by using the same chromatographic method at atmospheric pressure at 25°C with the boron concentration of 10 mmol/L, but were larger than the values at the same condition with much higher concentration of 100 and 501 mmol/L, indicating that borate-polymerization reducing the isotopic fractionation was negligible. However, calculations based on the theory of isotope distribution between two phases estimated that 21% (5MPa) and 47% (17MPa) of boron taken up in the resin phase was in the three-coordinated B(OH)3-form, instead of in the four-coordinated B(OH)4--form, at high pressures even with the very diluted solution. We discussed this discrepancy by introducing (1) hydration or (2) a partial molar volume difference between isotopic molecules. It was inferred that borate ions were partially dehydrated upon transfer from the solution phase to the resin phase at high pressures, which resulted in smaller S values compared with those at the atmospheric pressure. Alternatively, it was likely that the S value decreased with increasing pressure, because the difference of the partial isotopic molar volumes between 10B(OH)3 and 11B(OH)3 was larger than that between 10B(OH)4- and 11B(OH)4-. If either will be the case, the influence of a pressure upon the isotope effect may not be negligible for boron isotopic exchange equilibrium. This knowledge is crucial for the principle of the boron isotopic pH-metry reconstructing a chemical variation at the paleo-deep oceanic environment where the early life may have been evolved.

  4. Correlated XANES, TEM, and NanoSIMS of presolar graphite grains

    NASA Astrophysics Data System (ADS)

    Groopman, Evan E.; Nittler, Larry R.

    2018-01-01

    We report correlated XANES, TEM, and NanoSIMS measurements of twelve presolar graphite grains extracted from primitive meteorites and for which isotopic data indicate predominantly Type-II supernovae origins. We find continued evidence for isotopic heterogeneities in presolar graphite grains, including the first observation of a radial gradient in the inferred initial 26Al/27Al within a presolar graphite grain. The XANES spectra of these samples show a variety of minor absorbances near the C K-edge, attributable to vinyl-keto, aliphatic, carboxyl, and carbonate molecules, as well as possible damage during sample preparation. Each sample exhibits homogeneous C K-edge XANES spectra within the graphite, however, showing no correlation with isotopic heterogeneities. Gradients in the isotope ratios of C, N, O, and Al could be due to both processes during condensation, e.g., mixing in stellar ejecta and granular transport, and post-condensation effects, such as isotope dilution and exchange with isotopically normal material in the early Solar System or laboratory, the latter of which is a significant issue for high-density presolar graphite grains. It remains unknown whether the mechanisms behind isotope exchange would also affect the local chemistry and therefore the XANES spectra. Ti L-edge XANES from most Ti-rich subgrains match standard spectra for TiC and potentially TiCN. A rare rutile (TiO2) subgrain has been identified, though it lacks the lowest energy L3 peak typically seen in standard spectra. Ca has also been identified by EDXS in TiC subgrains, likely due to the decay of live 44Ti at the time of formation. Future NanoSIMS measurements will determine the variability of initial 44Ti in TiC subgrains, an important constraint on mixing in the ejecta of the grains' parent supernovae.

  5. Intrinsic ratios of glucose, fructose, glycerol and ethanol 13C/12C isotopic ratio determined by HPLC-co-IRMS: toward determining constants for wine authentication.

    PubMed

    Guyon, François; Gaillard, Laetitia; Salagoïty, Marie-Hélène; Médina, Bernard

    2011-09-01

    High-performance liquid chromatography linked to isotope ratio mass spectrometry (HPLC-co-IRMS) via a Liquiface© interface has been used to simultaneously determine (13)C isotope ratios of glucose (G), fructose (F), glycerol (Gly) and ethanol (Eth) in sweet and semi-sweet wines. The data has been used the study of wine authenticity. For this purpose, 20 authentic wines from various French production areas and various vintages have been analyzed after dilution in pure water from 20 to 200 times according to sugar content. If the (13)C isotope ratios vary according to the production area and the vintage, it appears that internal ratios of (13)C isotope ratios (R((13)C)) of the four compounds studied can be considered as a constant. Thus, ratios of isotope ratios are found to be 1.00 ± 0.04 and 1.02 ± 0.08 for R((13)C(G/F)) and R((13)C(Gly/Eth)), respectively. Moreover, R((13)C(Eth/Sugar)) is found to be 1.15 ± 0.10 and 1.16 ± 0.08 for R((13)C(Gly/Sugar)). Additions of glucose, fructose and glycerol to a reference wine show a variation of the R((13)C) value for a single product addition as low as 2.5 g/L(-1). Eighteen commercial wines and 17 concentrated musts have been analyzed. Three wine samples are suspicious as the R((13)C) values are out of range indicating a sweetening treatment. Moreover, concentrated must analysis shows that (13)C isotope ratio can be also used directly to determine the authenticity of the matrix.

  6. Nuclear and isotopic techniques for addressing nutritional problems, with special reference to current applications in developing countries.

    PubMed

    Iyengar, Venkatesh

    2002-03-01

    Nuclear and isotopic techniques are valuable tools in human nutritional research studies. Isotopes, both radioactive and nonradioactive, enable detailed evaluations of nutrient intake, body composition, energy expenditure, status of micronutrients, and nutrient bioavailability. In recent times, isotopic methods have been widely used in a number of coordinated research projects and technical cooperation projects of the International Atomic Energy Agency's Nutrition Programme. The doubly labeled water technique combines the use of the stable isotopes oxygen-18 and hydrogen-2 (deuterium) to measure total energy expenditure in free-living human subjects, and to investigate the magnitude and causes of both undernutrition and the emergence of obesity in developing countries. The deuterium dilution technique is a reliable tool to measure breastmilk intake and thereby infant growth and development. In collaboration with the World Health Organization's Growth Monitoring Program, this technique is being used to generate new data on growth standards for children in developing countries. This technique is also used in the measurement of body composition by the estimation of lean body mass and fat mass in individuals. Stable isotopes of iron and zinc have been successfully used to assess the nutritional impact of several nationwide food supplementation-programs conducted on pregnant and lactating women and children in both industrialized and developing countries. Isotopic techniques are especially suitable for monitoring changes in body composition, energy metabolism, and mineral status (with particular reference to osteoporosis) in the elderly. Nuclear methods have also served to develop models for a physiological reference man in Asia in support of radiological health and safety issues, for establishing elemental composition of foods, and for measurement of pollutants in the environment.

  7. Using multiple geochemical tracers to characterize the hydrogeology of the submarine spring off Crescent Beach, Florida

    USGS Publications Warehouse

    Swarzenski, P.W.; Reich, C.D.; Spechler, R.M.; Kindinger, J.L.; Moore, W.S.

    2001-01-01

    A spectacular submarine spring is located about 4 km east of Crescent Beach, FL, in the Atlantic Ocean. The single vent feature of Crescent Beach Spring provides a unique opportunity to examine onshore-offshore hydrogeologic processes, as well as point source submarine ground water discharge. The Floridan aquifer system in northeastern Florida consists of Tertiary interspersed limestone and dolomite strata. Impermeable beds confine the water-bearing zones under artesian pressure. Miocene and younger confining strata have been eroded away at the vent feature, enabling direct hydrologic communication of Eocene ground water with coastal bottom waters. The spring water had a salinity of 6.02, which was immediately diluted by ambient seawater during advection/mixing. The concentration of major solutes in spring water and onshore well waters confirm a generalized easterly flow direction of artesian ground water. Nutrient concentrations were generally low in the reducing vent samples, and the majority of the total nitrogen species existed as NH3. The submarine ground water tracers, Rn-222 (1174 dpm I-1, dpm), methane (232 nM) and barium (294.5 nM) were all highly enriched in the spring water relative to ambient seawater. The concentrations of the reverse redox elements U, V and Mo were expectedly low in the submarine waters. The strontium isotope ratio of the vent water (87Sr/86Sr = 0.70798) suggests that the spring water contain an integrated signature indicative of Floridan aquifer system ground water. Additional Sr isotopic ratios from a series of surficial and Lower Floridan well samples suggest dynamic ground water mixing, and do not provide clear evidence for a single hydrogeologic water source at the spring vent. In this karst-dominated aquifer, such energetic mixing at the vent feature is expected, and would be facilitated by conduit and fractured flow. Radium isotope activities were utilized to estimate flow-path trajectories and to provide information on potential travel times between an onshore well and the spring. Using either 223Ra and 224Ra or 228Ra, and qualifying this approach with several key assumptions, estimates of water mass travel times from an upper Floridan well in Crescent Beach to the submarine vent feature (distance =4050 m) are in the order of ??? 0.01-0.1 m min-1. ?? 2001 Elsevier Science B.V. All rights reserved.

  8. Serum apolipoprotein A-1 quantification by LC–MS with a SILAC internal standard reveals reduced levels in smokers

    PubMed Central

    Wang, Qingqing; Zhang, Suhong; Guo, Lili; Busch, Christine M; Jian, Wenying; Weng, Naidong; Snyder, Nathaniel W; Rangiah, Kannan; Mesaros, Clementina; Blair, Ian A

    2015-01-01

    Background: Absolute quantification of protein biomarkers such as serum apolipoprotein A1 by both immunoassays and LC–MS can provide misleading results. Results: Recombinant ApoA-1 internal standard was prepared using stable isotope labeling by amino acids in cell culture with [13C615N2]-lysine and [13C915N1]-tyrosine in human cells. A stable isotope dilution LC–MS method for serum ApoA-1 was validated and levels analyzed for 50 nonsmokers and 50 smokers. Conclusion: The concentration of ApoA-1 in nonsmokers was 169.4 mg/dl with an 18.4% reduction to 138.2 mg/dl in smokers. The validated assay will have clinical utility for assessing effects of smoking cessation and therapeutic or dietary interventions in high-risk populations. PMID:26394123

  9. Isotopic geochemistry of Panama rivers

    USGS Publications Warehouse

    Harmon, Russell S.; Worner, Gerhard; Pribil, Michael; Kern, Zoltan; Forizs, Istvan; Lyons, W. Berry; Gardner, Christopher B.; Goldsmith, Steven T.

    2015-01-01

    River water samples collected from 78 watersheds rivers along a 500-km transect across a Late Cretaceous-Tertiary andesitic volcanic arc terrane in west-central Panama provide a synoptic overview of riverine geochemistry, chemical denudation, and CO2 consumption in the tropics. D/H and 18O/16O relationships indicate that bedrock dissolution of andesitic arc crust in Panama is driven by water-rock interaction with meteoric precipitation as it passes through the critical zone, with no evidence of a geothermal or hydrothermal input. Sr-isotope relationships suggest a geochemical evolution for Panama riverine waters that involves mixing of bedrock pore water with water having 87Sr/86Sr ratios between 0.7037-0.7043 and relatively high Sr-contents with waters of low Sr content that enriched in radiogenic Sr that are diluted by infiltrating rainfall to variable extents.

  10. Rhenium-osmium isotope systematics in meteorites. I - Magmatic iron meteorite groups IIAB and IIIAB

    NASA Technical Reports Server (NTRS)

    Morgan, John W.; Walker, Richard J.; Grossman, Jeffery N.

    1992-01-01

    Resonance ionization mass spectrometry is used to determine the Re and Os abundances by isotope dilution (ID) and to measure Os-187/Os-186 ratios from 19 iron meteorites. Abundances range from 1.4 to 4800 ppb Re, and from 13 to 65,000 ppb Os, and generally agree well with previous ID and neutron activation results. The Re and Os data suggest that abundance trends in these iron groups may be entirely explained by fractional crystallization. Whole-rock isochrons for the IIAB and IIIAB groups are statistically indistinguishable. Pooled data yield an initial Os-187/Os-186 of 0.794 +/- 0.010 Ga. Given the errors in the slope and half life, this age does not differ significantly from the canonical chondrite age of 4.56 Ga, but could be as young as 4.46 Ga.

  11. Microstructure characterization of a food-grade U-type microemulsion system by differential scanning calorimetry and electrical conductivity techniques.

    PubMed

    Zhang, Hui; Taxipalati, Maierhaba; Que, Fei; Feng, Fengqin

    2013-12-01

    The microstructure transitions of a food-grade U-type microemulsion system containing glycerol monolaurate and propionic acid at a 1:1 mass ratio as oil phase and Tween 80 as surfactant were investigated along a water dilution line at a ratio of 80:20 mass% surfactant/oil phase, based on a previously studied phase diagram. From the water thermal behaviours detected by differential scanning calorimetry, three structural regions are identified along the dilution line. In the first region, all water molecules are confined to the water core of the reverse micelles, leading to the formation of w/o microemulsion. As the water content increases, the water gains mobility, transforms into bicontinuous in the second region, and finally the microemulsion become o/w in the third region. The thermal transition points coincide with the structural phase transitions by electrical conductivity measurements, indicating that the structural transitions occur at 35 and 65 mass% of water along the dilution line. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Characterization of commercial slovenian and cypriot fruit juices using stable isotopes.

    PubMed

    Ogrinc, Nives; Bat, Karmen; Kosir, Iztok Joze; Golob, Terezija; Kokkinofta, Rebecca

    2009-08-12

    The compositions of commercially available fruit juices on the Slovenian and Cypriot markets have been compared and checked against the corresponding declarations on the packaging. Values of delta(13)C in the pulp, sugars, and ethanol (produced by fermentation and distillation) have been obtained by isotope ratio mass spectrometry and (D/H)(I) and (D/H)(II) ratios determined by Site-specific Natural Isotope Fractionation NMR and compared with literature data. These data show that some juices on the Slovenian and Cypriot markets were adulterated. Measurements of delta(18)O in the water and of (D/H)(II) in the ethanol indicated a significant difference in commercially available juices due to differences of the "tap" water in Slovenia and Cyprus, as most of the juices were diluted from concentrate. Using Principal Component Analysis, very clear differentiation can be made between juices from the two countries, arising from their distinct aquatic environments and climates. The identification of botanical origin of fruit juices was possible only in the case of Slovenian orange and apple fruit juices.

  13. Round-robin 230Th– 234U age dating of bulk uranium for nuclear forensics

    DOE PAGES

    Gaffney, Amy M.; Hubert, Amélie; Kinman, William S.; ...

    2015-07-30

    We report that in an inter-laboratory measurement comparison study, four laboratories determined 230Th– 234U model ages of uranium certified reference material NBL U050 using isotope dilution mass spectrometry. The model dates determined by the participating laboratories range from 9 March 1956 to 19 October 1957, and are indistinguishable given the associated measurement uncertainties. These model ages are concordant with to slightly older than the known production age of NBL U050.

  14. Energetic Polyoxetane Thermoplastic Elastomers: Synthesis and Characterization

    DTIC Science & Technology

    1988-12-01

    Stockmayer, L. D. Moore, M. Fixman, and B. N. Epstein, Copolymers in Dilute Solution. I. Preliminary Results for Styrene- Methyl Methacrylate , J. Polym. Sci... methyl groups of p-dicumyl chloride showed a singlet peak at about 2.0 ppm. The integration ratio of the peak at 2.0 ppm and 7.6 ppm is about 3 within...were prepared by Aerojet. 1H and 13C NMR spectra of polymer solutions in deuteriochloro- form (CDCl3), MSD Isotopes, Montreal, Quebec, Canada, were

  15. Round-robin 230Th– 234U age dating of bulk uranium for nuclear forensics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gaffney, Amy M.; Hubert, Amélie; Kinman, William S.

    We report that in an inter-laboratory measurement comparison study, four laboratories determined 230Th– 234U model ages of uranium certified reference material NBL U050 using isotope dilution mass spectrometry. The model dates determined by the participating laboratories range from 9 March 1956 to 19 October 1957, and are indistinguishable given the associated measurement uncertainties. These model ages are concordant with to slightly older than the known production age of NBL U050.

  16. Quantitative Determination of Caffeine in Beverages Using a Combined SPME-GC/MS Method

    NASA Astrophysics Data System (ADS)

    Pawliszyn, Janusz; Yang, Min J.; Orton, Maureen L.

    1997-09-01

    Solid-phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS) has been applied to the analysis of various caffeinated beverages. Unlike the current methods, this technique is solvent free and requires no pH adjustments. The simplicity of the SPME-GC/MS method lends itself to a good undergraduate laboratory practice. This publication describes the analytical conditions and presents the data for determination of caffeine in coffee, tea, and coke. Quantitation by isotopic dilution is also illustrated.

  17. Major- and minor-metal composition of three distinct solid material fractions associated with Juan de Fuca hydrothermal fluids (northeast Pacific), and calculation of dilution fluid samples

    USGS Publications Warehouse

    Hinkley, T.K.; Seeley, J.L.; Tatsumoto, M.

    1988-01-01

    Three distinct types of solid material are associated with each sample of the hydrothermal fluid that was collected from the vents of the Southern Juan de Fuca Ridge. The solid materials appear to be representative of deposits on ocean floors near mid-ocean ridges, and interpretation of the chemistry of the hydrothermal solutions requires understanding of them. Sr isotopic evidence indicates that at least two and probably all three of these solid materials were removed from the solution with which they are associated, by precipitation or adsorption. This occurred after the "pure" hydrothermal fluid was diluted and thoroughly mixed with ambient seawater. The three types of solid materials, are, respectively, a coarse Zn- and Fe-rich material with small amounts of Na and Ca; a finer material also rich in Zn and Fe, but with alkali and alkaline-earth metals; and a scum composed of Ba or Zn, with either considerable Fe or Si, and Sr. Mineral identification is uncertain because of uncertain anion composition. Only in the cases of Ba and Zn were metal masses greater in solid materials than in the associated fluids. For all other metals measured, masses in fluids dwarf those in solids. The fluids themselves contain greater concentrations of all metals measured, except Mg, than seawater. We discuss in detail the relative merits of two methods of determining the mixing proportions of "pure" hydrothermal solution and seawater in the fluids, one based on Sr isotopes, and another previously used method based on Mg concentrations. Comparison of solute concentrations in the several samples shows that degree of dilution of "pure" hydrothermal solutions by seawater, and amounts of original solutes that were removed from it as solid materials, are not related. There is no clear evidence that appreciable amounts of solid materials were not conserved (lost) either during or prior to sample collection. ?? 1988.

  18. Measurement of late-night salivary cortisol with an automated immunoassay system.

    PubMed

    Vogeser, Michael; Durner, Jürgen; Seliger, Ewald; Auernhammer, Christoph

    2006-01-01

    Measurement of late-night salivary cortisol concentrations is increasingly used as a screening test in suspected Cushing's syndrome. Cortisol concentrations are typically extremely low in late-night samples and discordant assay-specific reference ranges have been reported. Therefore, the aim of our study was to assess the analytical performance of the first automated cortisol immunoassay specified for salivary measurements and to establish late-night sampling reference-range data for this test. Salivary cortisol was measured using the Roche Cobas Cortisol assay (Roche Diagnostics). Five salivary pools in different concentration ranges were used to assess the inter-assay imprecision of this test in a two-centre evaluation protocol including two reagent lots. Linearity was tested by serial dilution. Salivary samples were obtained at 23:00 h from 100 apparently healthy volunteers using a commercially available salivary sampling device (Salivette, Sarstedt). A subset of 20 samples was used for method comparison with isotope dilution liquid chromatography-tandem mass spectrometry. Inter-assay coefficients of variation (n=20) between 11.6% and 40.4% were found for mean cortisol concentrations between 12.9 and 2.6 nmol/L, with an estimated functional sensitivity of approximately 5.0 nmol/L. The test also gave linear results in the lowest concentration range between 1.0 and 8.3 nmol/L. Mean late-night salivary cortisol of 5.0 nmol/L was found for healthy individuals; the absolute range was 1.4-16.7 nmol/L, and the 95th percentile was 8.9 nmol/L. Substantially lower concentrations were found with isotope dilution LC-MS/MS compared to immunoassay results (mean concentrations 1.8 and 4.4 nmol/L, respectively). The automated assay investigated was found to offer acceptable analytical performance in the very low concentration range required for late-night salivary cortisol, despite a very short turn-around time. Using this assay, late-night salivary cortisol concentrations below 8.9 nmol/L are typically found in healthy volunteers.

  19. Waters associated with an active basaltic volcano, Kilauea, Hawaii: Variation in solute sources, 1973-1991

    USGS Publications Warehouse

    Tilling, R.I.; Jones, B.F.

    1996-01-01

    Chemical and isotopic analyses of samples collected from a 1262-m-deep research borehole at the summit of Kilauea Volcano provide unique time-series data for composition of waters in the uppermost part of its hydrothermal system. These waters have a distinctive geochemical signature: a very low proportion of chloride relative to other anions compared with other Hawaiian wa-ters - thermal (???30 ??C) or nonthermal (<30 ??C) - and with most thermal waters of the world. Isotope data demonstrate that the borehole waters are of essentially meteoric origin, with minimal magmatic input. The water chemistry exhibits marked temporal variations, including pronounced short-term (days to weeks) effects of rainfall dilution and longer term (months to years) decline of total solutes. The 1973-1974 samples are Na-sulfate-dominant, but samples collected after July 1975 are (Mg + Ca)-bicarbonate-dominant. This compositional shift, probably abrupt, was associated with an increase in the partial pressure of CO2 (PCO2) related to volcanic degassing of CO2 accompanying a large eruption (December 31, 1974) and associated intense seismicity. Following the initial sharp increase, the PCO2 then decreased, approaching preemption values in April 1976. Beginning in mid-1975, solute concentrations of the borehole waters decreased substantially, from ???45 meq/L to <25 meq/L in only eight months; by 1991, total solute concentrations were <17 meq/L. This decline in solutes cannot be attributed to rainfall dilution and is inferred to reflect the decreasing availability with time of the easily leachable salts of alkali metals and sulfate, which originated in sublimates and fumarolic encrustations in fractures and cavities of rocks along the hydrologic flow paths. The overall chemistry of the summit-borehole waters is largely determined by hydrolysis reactions associated with normal weathering of host tholeiitic basalts on a geologic time scale, despite short-term perturbations in composition caused by rainfall dilution or volcanic activity.

  20. The end-Permian regression in the western Tethys: sedimentological and geochemical evidence from offshore the Persian Gulf, Iran

    NASA Astrophysics Data System (ADS)

    Tavakoli, Vahid; Naderi-Khujin, Mehrangiz; Seyedmehdi, Zahra

    2018-04-01

    Detailed sedimentological and geochemical records across the Permian-Triassic boundary (PTB) in five offshore wells of the central Persian Gulf served to interpret the end-Permian sea-level change in this region. A decrease in sea level at the PTB was established by petrographical and geochemical study of the boundary. Thin sections showed that Upper Permian strata are composed of dolomite with minor anhydrite, changing into limestone in Lower Triassic sediments. Brine dilution toward the boundary supports sea-level fall in the Permian-Triassic transition, reflected by a decrease in anhydrite content and a shallowing-upward trend from lagoonal to peritidal facies. Isotopic changes at the boundary are in favor of sea-level fall. Changes in both carbon (from about 4 to -1‰) and oxygen (from 2 to -5‰) stable isotopes show negative excursions. The shift in carbon isotope values is a global phenomenon and is interpreted as resulting from carbonate sediment interaction with 12C-rich waters at the end-Permian sea-level fall. However, the oxygen isotope shift is attributed to the effect of meteoric waters with negative oxygen isotope values. The increase in strontium isotope ratios is also consistent with the high rate of terrestrial input at the boundary. The effect of meteoric conditions during diagenesis is evident from vuggy and moldic porosities below the PTB. The following transgression at the base of the Triassic is evident from the presence of reworked fossils and intraclasts resulting from deposition from agitated water.

  1. Escherichia coli cell-free protein synthesis and isotope labeling of mammalian proteins.

    PubMed

    Terada, Takaho; Yokoyama, Shigeyuki

    2015-01-01

    This chapter describes the cell-free protein synthesis method, using an Escherichia coli cell extract. This is a cost-effective method for milligram-scale protein production and is particularly useful for the production of mammalian proteins, protein complexes, and membrane proteins that are difficult to synthesize by recombinant expression methods, using E. coli and eukaryotic cells. By adjusting the conditions of the cell-free method, zinc-binding proteins, disulfide-bonded proteins, ligand-bound proteins, etc., may also be produced. Stable isotope labeling of proteins can be accomplished by the cell-free method, simply by using stable isotope-labeled amino acid(s) in the cell-free reaction. Moreover, the cell-free protein synthesis method facilitates the avoidance of stable isotope scrambling and dilution over the recombinant expression methods and is therefore advantageous for amino acid-selective stable isotope labeling. Site-specific stable isotope labeling is also possible with a tRNA molecule specific to the UAG codon. By the cell-free protein synthesis method, coupled transcription-translation is performed from a plasmid vector or a PCR-amplified DNA fragment encoding the protein. A milligram quantity of protein can be produced with a milliliter-scale reaction solution in the dialysis mode. More than a thousand solution structures have been determined by NMR spectroscopy for uniformly labeled samples of human and mouse functional domain proteins, produced by the cell-free method. Here, we describe the practical aspects of mammalian protein production by the cell-free method for NMR spectroscopy. © 2015 Elsevier Inc. All rights reserved.

  2. Geochemistry of waters from springs, wells, and snowpack on and adjacent to Medicine Lake volcano, northern California

    USGS Publications Warehouse

    Mariner, R.H.; Lowenstern, Jacob B.

    1999-01-01

    Chemical analyses of waters from cold springs and wells of the Medicine Lake volcano and surrounding region indicate small chloride anomalies that may be due to water-rock interaction or limited mixing with high-temperature geothermal fluids. The Fall River Springs (FRS) with a combined discharge of approximately 37 m3/s, show a negative correlation between chloride (Cl) and temperature, implying that the Cl is not derived from a high-temperature geothermal fluid. The high discharge from the FRS indicates recharge over a large geographic region. Chemical and isotopic variations in the FRS show that they contain a mixture of three distinct waters. The isotopic composition of recharge on and adjacent to the volcano are estimated from the isotopic composition of snow and precipitation amounts adjusted for evapotranspiration. Enough recharge of the required isotopic composition (-100 parts per thousand ??D) is available from a combination of the Medicine Lake caldera, the Fall River basin and the Long Bell basin to support the slightly warmer components of the FRS (32 m3/s). The cold-dilute part of the FRS (approximately 5 m3/s) may recharge in the Bear Creek basin or at lower elevations in the Fall River basin.

  3. Use of Zn isotopes as a probe of anthropogenic contamination and biogeochemical processes in the Seine River, France

    NASA Astrophysics Data System (ADS)

    Chen, J.; Gaillardet, J.; Louvat, P.; Birck, J.

    2009-05-01

    Metal contamination is a major issue of human impact on the aqueous environment. River water is particularly susceptible to contamination for both dissolved and particulate loads, displaying a major challenge in understanding the dominant sources and pathways of metals in polluted drainage basins. Recent improvements in mass spectrometry allow isotopic measurements of "non-traditional" metals (Zn, Cu, Fe, etc.), making their isotopes a new potential device to investigate contamination of metals under dissolved and particulate forms in rivers. We focus here on Zn isotope geochemistry in the largely anthropized Seine River (France). A new protocol of two-column separation of Zn from dilute aqueous solution has been developed and proven to be reproducible and satisfactory for accurate measurement of Zn isotopic ratios in water samples by MC-ICP-MS (2σ = 0.04‰). Preliminary results show a total variation of 0.65‰ for δ66Zn in dissolved phases of the Seine basin, and a light isotope enrichment in anthropogenic sources compared to other water samples. The determined conservative behavior of Zn in river water makes its isotopes an effective probe of anthropogenic contamination. The natural and anthropogenic inputs were clearly identified and calculated based on Zn isotope compositions for dissolved loads. Suspended particular matters (SPM) display different Zn isotope compositions compared to dissolved loads, with a total δ66Zn variation of 0.22‰. Zn concentrations and its isotope compositions in SPM reveal inverse relationships as function of the distance from the headwater and the SPM content for geographical and temporal samples, respectively. The δ66Zn data in SPM are interpreted as reflecting the mixture of natural and anthropogenic particles. The correlation between dissolved and particulate δ66Zn shows that adsorption processes are not the dominant process making Zn enrichment in SPM. We report here for the first time systematic δ66Zn data in waters of a whole river basin, showing Zn isotopes a powerful probe to trace contamination sources and biogeochemical processes in hydrologic systems.

  4. Dual isotope plots reflect transformation pathways of pesticides: Potential to assess pesticide fate and elucidate transformation mechanisms

    NASA Astrophysics Data System (ADS)

    Meyer, Armin; Penning, Holger; Sorensen, Sebastian; Aamand, Jens; Elsner, Martin

    2010-05-01

    The degradation of pesticides in deeper soil layers and groundwater is of growing interest, because they have repeatedly been found in drinking water supply wells and may pose a risk to future water resources. Current assessment schemes face a common problem, however: natural degradation often cannot be reliably assessed by concentration measurements alone, since mass balances are difficult to establish and transformation cannot be distinguished from sorption or dilution. Even detection of metabolites may only give an incomplete picture. When several transformation pathways occur, some metabolites may be degraded or form bound residues so that the associated pathways may be missed. Our research shows that dual isotope plots derived from compound specific isotope analysis offer a novel approach to give additional, complementary insight into the natural degradation of pesticides. Detection of metabolites is not required, since the isotope fractionation can be fully observed in the pesticide itself. Specifically, different initial biotransformation reactions of the phenylurea herbicide isoproturon (3-(4-isopropylphenyl)-1,1-dimethylurea) in pure culture experiments with bacterial and fungal strains showed strongly pathway-dependent isotope fractionation. When analyzing isotopic changes in different parts of the isoproturon molecule, hydroxylation of the isopropyl group by fungi was found to be associated with C and H isotope fractionation. In contrast, hydrolysis by Arthrobacter globiformis D47 caused strong C and N isotope fractionation, albeit in a different manner than abiotic hydrolysis so that isotope measurements can distinguish between both modes of transformation. Likewise, we observed highly pathway-dependent C and N isotope fractionation of atrazine (1-chloro-3-ethylamino-5-isopropylamino-2,4,6-triazine). Desalkylation of atrazine by Rhodococcus sp. strain NI86/21 resulted in enrichment of both 13-C and 15-N in atrazine, whereas hydrolysis to hydroxyatrazine by Chelatobacter heintzii, Pseudomonas sp. ADP and Arthrobacter aurescens TC1 gave enrichment of 13-C, but depletion of 15-N. Comparison with abiotic reference experiments provided novel insight into the underlying enzymatic transformation mechanisms. Our investigations show how characteristic isotope patterns may significantly add to the present understanding of the environmental fate of pesticides.

  5. Nitrogen isotope effects induced by anammox bacteria

    PubMed Central

    Brunner, Benjamin; Contreras, Sergio; Lehmann, Moritz F.; Matantseva, Olga; Rollog, Mark; Kalvelage, Tim; Klockgether, Gabriele; Lavik, Gaute; Jetten, Mike S. M.; Kartal, Boran; Kuypers, Marcel M. M.

    2013-01-01

    Nitrogen (N) isotope ratios (15N/14N) provide integrative constraints on the N inventory of the modern ocean. Anaerobic ammonium oxidation (anammox), which converts ammonium and nitrite to dinitrogen gas (N2) and nitrate, is an important fixed N sink in marine ecosystems. We studied the so far unknown N isotope effects of anammox in batch culture experiments. Anammox preferentially removes 14N from the ammonium pool with an isotope effect of +23.5‰ to +29.1‰, depending on factors controlling reversibility. The N isotope effects during the conversion of nitrite to N2 and nitrate are (i) inverse kinetic N isotope fractionation associated with the oxidation of nitrite to nitrate (−31.1 ± 3.9‰), (ii) normal kinetic N isotope fractionation during the reduction of nitrite to N2 (+16.0 ± 4.5‰), and (iii) an equilibrium N isotope effect between nitrate and nitrite (−60.5 ± 1.0‰), induced when anammox is exposed to environmental stress, leading to the superposition of N isotope exchange effects upon kinetic N isotope fractionation. Our findings indicate that anammox may be responsible for the unresolved large N isotope offsets between nitrate and nitrite in oceanic oxygen minimum zones. Irrespective of the extent of N isotope exchange between nitrate and nitrite, N removed from the combined nitrite and nitrate (NOx) pool is depleted in 15N relative to NOx. This net N isotope effect by anammox is superimposed on the N isotope fractionation by the co-occurring reduction of nitrate to nitrite in suboxic waters, possibly enhancing the overall N isotope effect for N loss from oxygen minimum zones. PMID:24191043

  6. A mass-balance code for the quantitative interpretation of fluid column profiles in ground-water studies

    NASA Astrophysics Data System (ADS)

    Paillet, Frederick

    2012-08-01

    A simple mass-balance code allows effective modeling of conventional fluid column resistivity logs in dilution tests involving column replacement with either distilled water or dilute brine. Modeling a series of column profiles where the inflowing formation water introduces water quality interfaces propagating along the borehole gives effective estimates of the rate of borehole flow. Application of the dilution model yields estimates of borehole flow rates that agree with measurements made with the heat-pulse flowmeter under ambient and pumping conditions. Model dilution experiments are used to demonstrate how dilution logging can extend the range of borehole flow measurement at least an order of magnitude beyond that achieved with flowmeters. However, dilution logging has the same dynamic range limitation encountered with flowmeters because it is difficult to detect and characterize flow zones that contribute a small fraction of total flow when that contribution is superimposed on a larger flow. When the smaller contribution is located below the primary zone, ambient downflow may disguise the zone if pumping is not strong enough to reverse the outflow. This situation can be addressed by increased pumping. But this is likely to make the moveout of water quality interfaces too fast to measure in the upper part of the borehole, so that a combination of flowmeter and dilution method may be more appropriate. Numerical experiments show that the expected weak horizontal flow across the borehole at conductive zones would be almost impossible to recognize if any ambient vertical flow is present. In situations where natural water quality differences occur such as flowing boreholes or injection experiments, the simple mass-balance code can be used to quantitatively model the evolution of fluid column logs. Otherwise, dilution experiments can be combined with high-resolution flowmeter profiles to obtain results not attainable using either method alone.

  7. A comparison of DNA extraction protocols from blood spotted on FTA cards for the detection of tick-borne pathogens by Reverse Line Blot hybridization.

    PubMed

    Hailemariam, Zerihun; Ahmed, Jabbar Sabir; Clausen, Peter-Henning; Nijhof, Ard Menzo

    2017-01-01

    An essential step in the molecular detection of tick-borne pathogens (TBPs) in blood is the extraction of DNA. When cooled storage of blood under field conditions prior to DNA extraction in a dedicated laboratory is not possible, the storage of blood on filter paper forms a promising alternative. We evaluated six DNA extraction methods from blood spotted on FTA Classic ® cards (FTA cards), to determine the optimal protocol for the subsequent molecular detection of TBPs by PCR and the Reverse Line Blot hybridization assay (RLB). Ten-fold serial dilutions of bovine blood infected with Babesia bovis, Theileria mutans, Anaplasma marginale or Ehrlichia ruminantium were made by dilution with uninfected blood and spotted on FTA cards. Subsequently, DNA was extracted from FTA cards using six different DNA extraction protocols. DNA was also isolated from whole blood dilutions using a commercial kit. PCR/RLB results showed that washing of 3mm discs punched from FTA cards with FTA purification reagent followed by DNA extraction using Chelex ® resin was the most sensitive procedure. The detection limit could be improved when more discs were used as starting material for the DNA extraction, whereby the use of sixteen 3mm discs proved to be most practical. The presented best practice method for the extraction of DNA from blood spotted on FTA cards will facilitate epidemiological studies on TBPs. It may be particularly useful for field studies where a cold chain is absent. Copyright © 2016 Elsevier GmbH. All rights reserved.

  8. Minimising reversion, using seawater and magnesium chloride, caused by the dissolution of tricalcium aluminate hexahydrate.

    PubMed

    Palmer, Sara J; Frost, Ray L; Smith, Matthew K

    2011-01-15

    The increase in pH and aluminium concentration after the neutralisation of bauxite refinery residues is commonly known as reversion. This investigation reports the extent of reversion in synthetic supernatant liquor and possible methods to reduce reversion. This work is based on bauxite refinery residues produced from alumina refineries, where reversion is a real life situation in neutralised refinery residues. Tricalcium aluminate hexahydrate, a common phase in bauxite refinery residues, has been found to cause reversion. It has been established that reductions in both pH and aluminium from the seawater neutralisation process are due to the formation of 'Bayer' hydrotalcite Mg(7)Al(2)(OH)(18)(CO(3)(2-),SO(4)(2-))·xH(2)O. This is the primary mechanism involved in the removal of aluminium from solution. Increasing the volume of seawater used for the neutralisation process minimises the extent of reversion for both synthetic supernatant liquor and red mud slurry. The addition of MgCl(2)·6H(2)O also showed a reduction in reversion and confirmed that the decrease in aluminium and hydroxyl ions is due to the formation of Bayer hydrotalcite and not simply a dilution effect. Copyright © 2010 Elsevier Inc. All rights reserved.

  9. Discriminating fluid source regions in orogenic gold deposits using B-isotopes

    NASA Astrophysics Data System (ADS)

    Lambert-Smith, James S.; Rocholl, Alexander; Treloar, Peter J.; Lawrence, David M.

    2016-12-01

    The genesis of orogenic gold deposits is commonly linked to hydrothermal ore fluids derived from metamorphic devolatilization reactions. However, there is considerable debate as to the ultimate source of these fluids and the metals they transport. Tourmaline is a common gangue mineral in orogenic gold deposits. It is stable over a very wide P-T range, demonstrates limited volume diffusion of major and trace elements and is the main host of B in most rock types. We have used texturally resolved B-isotope analysis by secondary ion mass spectrometry (SIMS) to identify multiple fluid sources within a single orogenic gold ore district. The Loulo Mining District in Mali, West Africa hosts several large orogenic gold ore bodies with complex fluid chemistry, associated with widespread pre-ore Na- and multi-stage B-metasomatism. The Gara deposit, as well as several smaller satellites, formed through partial mixing between a dilute aqueous-carbonic fluid and a hypersaline brine. Hydrothermal tourmaline occurs as a pre-ore phase in the matrix of tourmalinite units, which host mineralization in several ore bodies. Clasts of these tourmalinites occur in mineralized breccias. Disseminated hydrothermal and vein hosted tourmaline occur in textural sites which suggest growth during and after ore formation. Tourmalines show a large range in δ11B values from -3.5 to 19.8‰, which record a change in fluid source between paragenetic stages of tourmaline growth. Pre-mineralization tourmaline crystals show heavy δ11B values (8-19.8‰) and high X-site occupancy (Na ± Ca; 0.69-1 apfu) suggesting a marine evaporite source for hydrothermal fluids. Syn-mineralization and replacement phases show lighter δ11B values (-3.5 to 15.1‰) and lower X-site occupancy (0.62-0.88 apfu), suggesting a subsequent influx of more dilute fluids derived from devolatilization of marine carbonates and clastic metasediments. The large, overlapping range in isotopic compositions and a skew toward the opposing population in the δ11B data for both tourmaline groups reflects continual tourmaline growth throughout mineralization, which records the process of fluid mixing. A peak in δ11B values at ∼8‰ largely controlled by tourmalines of syn- to post-ore timing represents a mixture of the two isotopically distinct fluids. This paper demonstrates that B-isotopes in tourmaline can be instrumental in interpreting complex and dynamic hydrothermal systems. The importance of B as an integral constituent of orogenic ore forming fluids and as a gangue phase in orogenic gold deposits makes B-isotope analysis a powerful tool for testing the level of source region variability in these fluids, and by extension, that of metal sources.

  10. Intraoperative anaphylaxis to sugammadex and a protocol for intradermal skin testing.

    PubMed

    Sadleir, P H M; Russell, T; Clarke, R C; Maycock, E; Platt, P R

    2014-01-01

    Sugammadex is a selective binding agent for aminosteroid neuromuscular blockers whose use is increasing in anaesthetic practice. We present three cases of severe anaphylaxis coincident with sugammadex administration. Subsequent intradermal testing confirmed sugammadex as the triggering agent, with all patients having positive skin responses to a 1:100 dilution of the standard 100 mg/ml solution and two out of three having a positive response to a 1:1000 dilution. As all patients were administered sugammadex to reverse neuromuscular blockade with rocuronium, we considered that sugammadex-rocuronium complexes were a potential unique allergen. In the two patients who were additionally tested with a rocuronium-sugammadex (3.6:1 molecular ratio) mixture, the wheal-and-flare response was significantly attenuated.

  11. Reversing DNA Methylation: Mechanisms, Genomics, and Biological Functions

    PubMed Central

    Wu, Hao; Zhang, Yi

    2014-01-01

    Methylation of cytosines in the mammalian genome represents a key epigenetic modification and is dynamically regulated during development. Compelling evidence now suggests that dynamic regulation of DNA methylation is mainly achieved through a cyclic enzymatic cascade comprised of cytosine methylation, iterative oxidation of methyl group by TET dioxygenases, and restoration of unmodified cytosines by either replication-dependent dilution or DNA glycosylase-initiated base excision repair. In this review, we discuss the mechanism and function of DNA demethylation in mammalian genomes, focusing particularly on how developmental modulation of the cytosine-modifying pathway is coupled to active reversal of DNA methylation in diverse biological processes. PMID:24439369

  12. Effect of flow rate and concentration difference on reverse electrodialysis system

    NASA Astrophysics Data System (ADS)

    Kwon, Kilsugn; Han, Jaesuk; Kim, Daejoong

    2013-11-01

    Various energy conversion technologies have been developed to reduce dependency on limited fossil fuels, including wind power, solar power, hydropower, ocean power, and geothermal power. Among them, reverse electrodialysis (RED), which is one type of salinity gradient power (SGP), has received much attention due to high reliability and simplicity without moving parts. Here, we experimentally evaluated the RED performance with several parameters like flow rate of concentrated and dilute solution, concentration difference, and temperature. RED was composed of endplates, electrodes, spacers, anion exchange membrane, and cation exchange membrane. Endplates are made by a polypropylene. It included the electrodes, flow field for the electrode rinse solution, and path to supply a concentrated and dilute solution. Titanium coated by iridium and ruthenium was used as the electrode. The electrode rinse solution based on hexacyanoferrate system is used to reduce the power loss generated by conversion process form ionic current to electric current. Maximum power monotonously increases as increasing flow rate and concentration difference. Net power has optimal point because pumping power consumption increases with flow rate. This work was supported by Basic Science Research Program (Grat No. NRF-2011-0009993) through the National Research Foundation of Korea.

  13. Coupling Influences SMM Properties for Pure 4 f Systems.

    PubMed

    Zhang, Xuejing; Liu, Shuang; Vieru, Veacheslav; Xu, Na; Gao, Chen; Wang, Bing-Wu; Shi, Wei; Chibotaru, Liviu F; Gao, Song; Cheng, Peng; Powell, Annie K

    2018-04-20

    Increasing both the energy barrier for magnetization reversal and the coercive field of the hysteresis loop are significant challenges in the field of single-molecule magnets (SMMs). Coordination geometries of lanthanide ions and magnetic interactions between lanthanide ions are both important for guiding the magnetic behavior of SMMs. We report a high energy barrier of 657 K (457 cm -1 ) in a diamagnetic-ion-diluted lanthanide chain compound with a constrained bisphenoid symmetry (D 2d ); this energy barrier is substantially higher than the barrier of 567 K (394 cm -1 ) of the non-diluted chain compound with intrachain ferromagnetic interactions. Although intrachain magnetic interaction lowers the energy barrier for magnetization reversal, it can greatly enhance the coercive fields and zero-field remanence of the hysteresis loops, which is crucial for the rational design of high-performance SMMs. Factors related to the coordination sphere of the lanthanide center, which govern the high magnetic relaxation barriers through the second excited Kramer's doublets and the magnetic interactions that affect the hysteresis loops, were revealed through ab initio calculations. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. A dilute-and-shoot flow-injection tandem mass spectrometry method for quantification of phenobarbital in urine.

    PubMed

    Alagandula, Ravali; Zhou, Xiang; Guo, Baochuan

    2017-01-15

    Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized. This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard. The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections. Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Direct aqueous determination of glyphosate and related compounds by liquid chromatography/tandem mass spectrometry using reversed-phase and weak anion-exchange mixed-mode column.

    PubMed

    Hao, Chunyan; Morse, David; Morra, Franca; Zhao, Xiaoming; Yang, Paul; Nunn, Brian

    2011-08-19

    Analysis of the broad-spectrum herbicide glyphosate and its related compounds is quite challenging. Tedious and time-consuming derivatization is often required for these substances due to their high polarity, high water solubility, low volatility and molecular structure which lacks either a chromophore or fluorophore. A novel liquid chromatography/tandem mass spectrometry (LC/MS-MS) method has been developed for the determination of glyphosate, aminomethylphosphonic acid (AMPA) and glufosinate using a reversed-phase and weak anion-exchange mixed-mode Acclaim® WAX-1 column. Aqueous environmental samples are directly injected and analyzed in 12 min with no sample concentration or derivatization steps. Two multiple reaction monitoring (MRM) channels are monitored in the method for each target compound to achieve true positive identification, and ¹³C, ¹⁵N-glyphosate is used as an internal standard to carry out isotope dilution mass spectrometric (IDMS) measurement for glyphosate. The instrument detection limits (IDLs) for glyphosate, AMPA and glufosinate are 1, 2 and 0.9 μg/L, respectively. Linearity of the detector response with a minimum coefficient of determination (R² value (R² > 0.995) was demonstrated in the range of ∼10 to 10³ μg/L for each analytes. Spiked drinking water, surface water and groundwater samples were analyzed using this method and the average recoveries of analytes in three matrices ranged from 77.0 to 102%, 62.1 to 101%, 66.1 to 93.7% while relative standard deviation ranged from 6.3 to 10.2%, 2.7 to 14.8%, 2.9 to 10.7%, respectively. Factors that may affect method performance, such as metal ions, sample preservation, and storage time, are also discussed. Crown Copyright © 2011. Published by Elsevier B.V. All rights reserved.

  16. Nuclear astrophysics with radioactive ions at FAIR

    NASA Astrophysics Data System (ADS)

    Reifarth, R.; Altstadt, S.; Göbel, K.; Heftrich, T.; Heil, M.; Koloczek, A.; Langer, C.; Plag, R.; Pohl, M.; Sonnabend, K.; Weigand, M.; Adachi, T.; Aksouh, F.; Al-Khalili, J.; AlGarawi, M.; AlGhamdi, S.; Alkhazov, G.; Alkhomashi, N.; Alvarez-Pol, H.; Alvarez-Rodriguez, R.; Andreev, V.; Andrei, B.; Atar, L.; Aumann, T.; Avdeichikov, V.; Bacri, C.; Bagchi, S.; Barbieri, C.; Beceiro, S.; Beck, C.; Beinrucker, C.; Belier, G.; Bemmerer, D.; Bendel, M.; Benlliure, J.; Benzoni, G.; Berjillos, R.; Bertini, D.; Bertulani, C.; Bishop, S.; Blasi, N.; Bloch, T.; Blumenfeld, Y.; Bonaccorso, A.; Boretzky, K.; Botvina, A.; Boudard, A.; Boutachkov, P.; Boztosun, I.; Bracco, A.; Brambilla, S.; Briz Monago, J.; Caamano, M.; Caesar, C.; Camera, F.; Casarejos, E.; Catford, W.; Cederkall, J.; Cederwall, B.; Chartier, M.; Chatillon, A.; Cherciu, M.; Chulkov, L.; Coleman-Smith, P.; Cortina-Gil, D.; Crespi, F.; Crespo, R.; Cresswell, J.; Csatlós, M.; Déchery, F.; Davids, B.; Davinson, T.; Derya, V.; Detistov, P.; Diaz Fernandez, P.; DiJulio, D.; Dmitry, S.; Doré, D.; Dueñas, J.; Dupont, E.; Egelhof, P.; Egorova, I.; Elekes, Z.; Enders, J.; Endres, J.; Ershov, S.; Ershova, O.; Fernandez-Dominguez, B.; Fetisov, A.; Fiori, E.; Fomichev, A.; Fonseca, M.; Fraile, L.; Freer, M.; Friese, J.; Borge, M. G.; Galaviz Redondo, D.; Gannon, S.; Garg, U.; Gasparic, I.; Gasques, L.; Gastineau, B.; Geissel, H.; Gernhäuser, R.; Ghosh, T.; Gilbert, M.; Glorius, J.; Golubev, P.; Gorshkov, A.; Gourishetty, A.; Grigorenko, L.; Gulyas, J.; Haiduc, M.; Hammache, F.; Harakeh, M.; Hass, M.; Heine, M.; Hennig, A.; Henriques, A.; Herzberg, R.; Holl, M.; Ignatov, A.; Ignatyuk, A.; Ilieva, S.; Ivanov, M.; Iwasa, N.; Jakobsson, B.; Johansson, H.; Jonson, B.; Joshi, P.; Junghans, A.; Jurado, B.; Körner, G.; Kalantar, N.; Kanungo, R.; Kelic-Heil, A.; Kezzar, K.; Khan, E.; Khanzadeev, A.; Kiselev, O.; Kogimtzis, M.; Körper, D.; Kräckmann, S.; Kröll, T.; Krücken, R.; Krasznahorkay, A.; Kratz, J.; Kresan, D.; Krings, T.; Krumbholz, A.; Krupko, S.; Kulessa, R.; Kumar, S.; Kurz, N.; Kuzmin, E.; Labiche, M.; Langanke, K.; Lazarus, I.; Le Bleis, T.; Lederer, C.; Lemasson, A.; Lemmon, R.; Liberati, V.; Litvinov, Y.; Löher, B.; Lopez Herraiz, J.; Münzenberg, G.; Machado, J.; Maev, E.; Mahata, K.; Mancusi, D.; Marganiec, J.; Martinez Perez, M.; Marusov, V.; Mengoni, D.; Million, B.; Morcelle, V.; Moreno, O.; Movsesyan, A.; Nacher, E.; Najafi, M.; Nakamura, T.; Naqvi, F.; Nikolski, E.; Nilsson, T.; Nociforo, C.; Nolan, P.; Novatsky, B.; Nyman, G.; Ornelas, A.; Palit, R.; Pandit, S.; Panin, V.; Paradela, C.; Parkar, V.; Paschalis, S.; Pawłowski, P.; Perea, A.; Pereira, J.; Petrache, C.; Petri, M.; Pickstone, S.; Pietralla, N.; Pietri, S.; Pivovarov, Y.; Potlog, P.; Prokofiev, A.; Rastrepina, G.; Rauscher, T.; Ribeiro, G.; Ricciardi, M.; Richter, A.; Rigollet, C.; Riisager, K.; Rios, A.; Ritter, C.; Rodriguez Frutos, T.; Rodriguez Vignote, J.; Röder, M.; Romig, C.; Rossi, D.; Roussel-Chomaz, P.; Rout, P.; Roy, S.; Söderström, P.; Saha Sarkar, M.; Sakuta, S.; Salsac, M.; Sampson, J.; Sanchez, J.; Rio Saez, del; Sanchez Rosado, J.; Sanjari, S.; Sarriguren, P.; Sauerwein, A.; Savran, D.; Scheidenberger, C.; Scheit, H.; Schmidt, S.; Schmitt, C.; Schnorrenberger, L.; Schrock, P.; Schwengner, R.; Seddon, D.; Sherrill, B.; Shrivastava, A.; Sidorchuk, S.; Silva, J.; Simon, H.; Simpson, E.; Singh, P.; Slobodan, D.; Sohler, D.; Spieker, M.; Stach, D.; Stan, E.; Stanoiu, M.; Stepantsov, S.; Stevenson, P.; Strieder, F.; Stuhl, L.; Suda, T.; Sümmerer, K.; Streicher, B.; Taieb, J.; Takechi, M.; Tanihata, I.; Taylor, J.; Tengblad, O.; Ter-Akopian, G.; Terashima, S.; Teubig, P.; Thies, R.; Thoennessen, M.; Thomas, T.; Thornhill, J.; Thungstrom, G.; Timar, J.; Togano, Y.; Tomohiro, U.; Tornyi, T.; Tostevin, J.; Townsley, C.; Trautmann, W.; Trivedi, T.; Typel, S.; Uberseder, E.; Udias, J.; Uesaka, T.; Uvarov, L.; Vajta, Z.; Velho, P.; Vikhrov, V.; Volknandt, M.; Volkov, V.; von Neumann-Cosel, P.; von Schmid, M.; Wagner, A.; Wamers, F.; Weick, H.; Wells, D.; Westerberg, L.; Wieland, O.; Wiescher, M.; Wimmer, C.; Wimmer, K.; Winfield, J. S.; Winkel, M.; Woods, P.; Wyss, R.; Yakorev, D.; Yavor, M.; Zamora Cardona, J.; Zartova, I.; Zerguerras, T.; Zgura, M.; Zhdanov, A.; Zhukov, M.; Zieblinski, M.; Zilges, A.; Zuber, K.

    2016-01-01

    The nucleosynthesis of elements beyond iron is dominated by neutron captures in the s and r processes. However, 32 stable, proton-rich isotopes cannot be formed during those processes, because they are shielded from the s-process flow and r-process, β-decay chains. These nuclei are attributed to the p and rp process. For all those processes, current research in nuclear astrophysics addresses the need for more precise reaction data involving radioactive isotopes. Depending on the particular reaction, direct or inverse kinematics, forward or time-reversed direction are investigated to determine or at least to constrain the desired reaction cross sections. The Facility for Antiproton and Ion Research (FAIR) will offer unique, unprecedented opportunities to investigate many of the important reactions. The high yield of radioactive isotopes, even far away from the valley of stability, allows the investigation of isotopes involved in processes as exotic as the r or rp processes.

  17. H-O isotopic and chemical characteristics of a precipitation-lake water-groundwater system in a desert area

    NASA Astrophysics Data System (ADS)

    Jin, Ke; Rao, Wenbo; Tan, Hongbing; Song, Yinxian; Yong, Bin; Zheng, Fangwen; Chen, Tangqing; Han, Liangfeng

    2018-04-01

    The recharge mechanism of groundwater in the Badain Jaran Desert, North China has been a focus of research and still disputable in the past two decades. In this study, the chemical and hydrogen (H) and oxygen (O) isotopic characteristics of shallow groundwater, lake water and local precipitation in the Badain Jaran Desert and neighboring areas were investigated to reveal the relationships between various water bodies and the recharge source of shallow groundwater. Isotopic and hydrogeochemical results show that (1) shallow groundwater was associated with local precipitation in the Ayouqi and Yabulai regions, (2) lake water was mainly recharged by groundwater in the desert hinterland, (3) shallow groundwater of the desert hinterland, Yabulai Mountain and Gurinai Grassland had a common recharge source. Shallow groundwater of the desert hinterland had a mean recharge elevation of 1869 m a.s.l. on the basis of the isotope-altitude relationship and thus originated chiefly from lateral infiltration of precipitation in the Yabulai Mountain. It is further concluded that shallow groundwater flowed towards the Gurinai Grassland according to the groundwater table contour map. Along the flow pathway, the H-O isotopic variations were primarily caused by the evaporation effect but chemical variations of shallow groundwater were affected by multiple factors, e.g., evaporation effect, dilution effect of occasional heavy-precipitation and dissolution of aquifer evaporites. Our findings provide new insight into the groundwater cycle and benefit the management of the limited water resources in the arid desert area.

  18. Analysis of gas membrane ultra-high purification of small quantities of mono-isotopic silane

    DOE PAGES

    de Almeida, Valmor F.; Hart, Kevin J.

    2017-01-03

    A small quantity of high-value, crude, mono-isotopic silane is a prospective gas for a small-scale, high-recovery, ultra-high membrane purification process. This is an unusual application of gas membrane separation for which we provide a comprehensive analysis of a simple purification model. The goal is to develop direct analytic expressions for estimating the feasibility and efficiency of the method, and guide process design; this is only possible for binary mixtures of silane in the dilute limit which is a somewhat realistic case. In addition, analytic solutions are invaluable to verify numerical solutions obtained from computer-aided methods. Hence, in this paper wemore » provide new analytic solutions for the purification loops proposed. Among the common impurities in crude silane, methane poses a special membrane separation challenge since it is chemically similar to silane. Other potential problematic compounds are: ethylene, diborane and ethane (in this order). Nevertheless, we demonstrate, theoretically, that a carefully designed membrane system may be able to purify mono-isotopic, crude silane to electronics-grade level in a reasonable amount of time and expenses. We advocate a combination of membrane materials that preferentially reject heavy impurities based on mobility selectivity, and light impurities based on solubility selectivity. We provide estimates for the purification of significant contaminants of interest. In this study, we suggest cellulose acetate and polydimethylsiloxane as examples of membrane materials on the basis of limited permeability data found in the open literature. We provide estimates on the membrane area needed and priming volume of the cell enclosure for fabrication purposes when using the suggested membrane materials. These estimates are largely theoretical in view of the absence of reliable experimental data for the permeability of silane. And finally, future extension of this work to the non-dilute limit may apply to the recovery of silane from rejected streams of natural silicon semi-conductor processes.« less

  19. Analysis of gas membrane ultra-high purification of small quantities of mono-isotopic silane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Almeida, Valmor F.; Hart, Kevin J.

    A small quantity of high-value, crude, mono-isotopic silane is a prospective gas for a small-scale, high-recovery, ultra-high membrane purification process. This is an unusual application of gas membrane separation for which we provide a comprehensive analysis of a simple purification model. The goal is to develop direct analytic expressions for estimating the feasibility and efficiency of the method, and guide process design; this is only possible for binary mixtures of silane in the dilute limit which is a somewhat realistic case. In addition, analytic solutions are invaluable to verify numerical solutions obtained from computer-aided methods. Hence, in this paper wemore » provide new analytic solutions for the purification loops proposed. Among the common impurities in crude silane, methane poses a special membrane separation challenge since it is chemically similar to silane. Other potential problematic compounds are: ethylene, diborane and ethane (in this order). Nevertheless, we demonstrate, theoretically, that a carefully designed membrane system may be able to purify mono-isotopic, crude silane to electronics-grade level in a reasonable amount of time and expenses. We advocate a combination of membrane materials that preferentially reject heavy impurities based on mobility selectivity, and light impurities based on solubility selectivity. We provide estimates for the purification of significant contaminants of interest. In this study, we suggest cellulose acetate and polydimethylsiloxane as examples of membrane materials on the basis of limited permeability data found in the open literature. We provide estimates on the membrane area needed and priming volume of the cell enclosure for fabrication purposes when using the suggested membrane materials. These estimates are largely theoretical in view of the absence of reliable experimental data for the permeability of silane. And finally, future extension of this work to the non-dilute limit may apply to the recovery of silane from rejected streams of natural silicon semi-conductor processes.« less

  20. Analysis of Gas Membrane Ultra-High Purification of Small Quantities of Mono-Isotopic Silane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Almeida, Valmor F.; Hart, Kevin J.

    A small quantity of high-value, crude, mono-isotopic silane is a prospective gas for a small-scale, high-recovery, ultra-high membrane purification process. This is an unusual application of gas membrane separation for which we provide a comprehensive analysis of a simple purification model. The goal is to develop direct analytic expressions for estimating the feasibility and efficiency of the method, and guide process design; this is only possible for binary mixtures of silane in the dilute limit which is a somewhat realistic case. Among the common impurities in crude silane, methane poses a special membrane separation challenge since it is chemically similarmore » to silane. Other potential problematic surprises are: ethylene, diborane and ethane (in this order). Nevertheless, we demonstrate, theoretically, that a carefully designed membrane system may be able to purify mono-isotopic, crude silane to electronics-grade level in a reasonable amount of time and expenses. We advocate a combination of membrane materials that preferentially reject heavy impurities based on mobility selectivity, and light impurities based on solubility selectivity. We provide estimates for the purification of significant contaminants of interest. To improve the separation selectivity, it is advantageous to use a permeate chamber under vacuum, however this also requires greater control of in-leakage of impurities in the system. In this study, we suggest cellulose acetate and polydimethylsiloxane as examples of membrane materials on the basis of limited permeability data found in the open literature. We provide estimates on the membrane area needed and priming volume of the cell enclosure for fabrication purposes when using the suggested membrane materials. These estimates are largely theoretical in view of the absence of reliable experimental data for the permeability of silane. Last but not least, future extension of this work to the non-dilute limit may apply to the recovery of silane from rejected streams of natural silicon semi-conductor processes.« less

  1. Large-Scale Interlaboratory Study to Develop, Analytically Validate and Apply Highly Multiplexed, Quantitative Peptide Assays to Measure Cancer-Relevant Proteins in Plasma*

    PubMed Central

    Abbatiello, Susan E.; Schilling, Birgit; Mani, D. R.; Zimmerman, Lisa J.; Hall, Steven C.; MacLean, Brendan; Albertolle, Matthew; Allen, Simon; Burgess, Michael; Cusack, Michael P.; Gosh, Mousumi; Hedrick, Victoria; Held, Jason M.; Inerowicz, H. Dorota; Jackson, Angela; Keshishian, Hasmik; Kinsinger, Christopher R.; Lyssand, John; Makowski, Lee; Mesri, Mehdi; Rodriguez, Henry; Rudnick, Paul; Sadowski, Pawel; Sedransk, Nell; Shaddox, Kent; Skates, Stephen J.; Kuhn, Eric; Smith, Derek; Whiteaker, Jeffery R.; Whitwell, Corbin; Zhang, Shucha; Borchers, Christoph H.; Fisher, Susan J.; Gibson, Bradford W.; Liebler, Daniel C.; MacCoss, Michael J.; Neubert, Thomas A.; Paulovich, Amanda G.; Regnier, Fred E.; Tempst, Paul; Carr, Steven A.

    2015-01-01

    There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma. PMID:25693799

  2. Evolution of carbon isotope signatures during reactive transport of hydrocarbons in heterogeneous aquifers.

    PubMed

    Höyng, Dominik; Prommer, Henning; Blum, Philipp; Grathwohl, Peter; D'Affonseca, Fernando Mazo

    2015-03-01

    Compound-specific isotope analysis (CSIA) of organic pollutants has become a well-established tool for assessing the occurrence and extent of biodegradation processes in contaminated aquifers. However, the precision of CSIA is influenced by the degree to which assumptions underlying CSIA data interpretation hold under realistic field-scale conditions. For the first time this study demonstrates how aquifer analogs combined with reactive transport models offer an underexplored way to develop generic process understanding, evaluate monitoring and quantification strategies in highly heterogeneous subsurface settings. Data from high-resolution aquifer analogs were used in numerical experiments to track the propagation of a representative oxidizable organic compound (toluene) within a variety of realistic heterogeneous aquifers and to investigate its detailed fate. The simulations were used to analyze (1) the effects of physical aquifer heterogeneities on spatiotemporal patterns of contaminant concentrations and isotope signatures, (2) the performance of the commonly applied Rayleigh equation and (3) the applicability of an extension of the Rayleigh equation for complex hydrogeological conditions. The results indicate that if field-derived enrichment factors are applied without corrections for dilution, the conventional Rayleigh equation is inaccurate and estimates for biodegradation are typically overestimated and unreliable in heterogeneous aquifers. Underestimations can occur due to the partial source zone depletion. In contrast, if dilution can be accurately accounted for, field-derived enrichment factors comprise a suitable alternative to laboratory-derived and redox-specific enrichment factors. The study also examines to what extent variations in monitoring/sampling strategies influence the obtained results. Especially measurements from long-screened wells (>1 m) reveal to be inappropriate for the application of the Rayleigh equation in the investigated aquifer analogs, as low resolution data sampled from the simulated scenarios only enable a qualitative assessment of biodegradation. Measurements from both long- and short-screened wells employing the Rayleigh equation streamline approach are only partly viable for in situ biodegradation measurements in heterogeneous systems. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Assessing the fate of radioactive nickel in cultivated soil cores.

    PubMed

    Denys, Sébastien; Echevarria, Guillaume; Florentin, Louis; Leclerc, Elisabeth; Morel, Jean-Louis

    2009-10-01

    Parameters regarding fate of (63)Ni in the soil-plant system (soil: solution distribution coefficient, K(d) and soil plant concentration ratio, CR) are mostly determined in controlled pot experiments or from simple models involving a limited set of soil parameters. However, as migration of pollutants in soil is strongly linked to the water migration, variation of soil structure in the field and seasonal variation of evapotranspiration will affect these two parameters. The aim of this work was to explore to what extent the downward transfer of (63)Ni and its uptake by plants from surface-contaminated undisturbed soil cores under cultivation can be explained by isotopic dilution of this radionuclide in the pool of stable Ni of soils. Undisturbed soil cores (50 cm x 50 cm) were sampled from a brown rendzina (Rendzic Leptosol), a colluvial brown soil (Fluvic Cambisol) and an acidic brown soil (Dystric Cambisol) using PVC lysimeter tubes (three lysimeters sampled per soil type). Each core was equipped with a leachate collector. Cores were placed in a greenhouse and maize (DEA, Pioneer) was sown. After 44 days, an irrigation was simulated at the core surfaces to supply 10 000 Bq (63)NiCl(2). Maize was harvested 135 days after (63)Ni input and radioactivity determined in both vegetal and water samples. Effective uptake of (63)Ni by maize was calculated for leaves and kernels. Water drainage and leaching of (63)Ni were monitored over the course of the experiment. Values of K(d) in surface soil samples were calculated from measured parameters of isotopic exchange kinetics. Results confirmed that (63)Ni was strongly retained at the soil surface. Prediction of the (63)Ni downward transfer could not be reliably assessed using the K(d) values, since the soil structure, which controls local water fluxes, also affected both water and Ni transport. In terms of (63)Ni plant uptake, the effective uptake in undisturbed soil cores is controlled by isotope dilution as previously shown at the pot experiment scale.

  4. Application of isotope-dilution laser ablation ICP-MS for direct determination of Pu concentrations in soils at pg g(-1) levels.

    PubMed

    Boulyga, Sergei F; Tibi, Markus; Heumann, Klaus G

    2004-01-01

    The methods available for determination of environmental contamination by plutonium at ultra-trace levels require labor-consuming sample preparation including matrix removal and plutonium extraction in both nuclear spectroscopy and mass spectrometry. In this work, laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was applied for direct analysis of Pu in soil and sediment samples. Application of a LINA-Spark-Atomizer system (a modified laser ablation system providing high ablation rates) coupled with a sector-field ICP-MS resulted in detection limits as low as 3x10(-13) g g(-1) for Pu isotopes in soil samples containing uranium at a concentration of a few microg g(-1). The isotope dilution (ID) technique was used for quantification, which compensated for matrix effects in LA-ICP-MS. Interferences by UH+ and PbO2+ ions and by the peak tail of 238U+ ions were reduced or separated by use of dry plasma conditions and a mass resolution of 4000, respectively. No other effects affecting measurement accuracy, except sample inhomogeneity, were revealed. Comparison of results obtained for three contaminated soil samples by use of alpha-spectrometry, ICP-MS with sample decomposition, and LA-ICP-IDMS showed, in general, satisfactory agreement of the different methods. The specific activity of (239+240)Pu (9.8 +/- 3.0 mBq g(-1)) calculated from LA-ICP-IDMS analysis of SRM NIST 4357 coincided well with the certified value of 10.4 +/- 0.2 mBq g(-1). However, the precision of LA-ICP-MS for determination of plutonium in inhomogeneous samples, i.e. if "hot" particles are present, is limited. As far as we are aware this paper reports the lowest detection limits and element concentrations yet measured in direct LA-ICP-MS analysis of environmental samples.

  5. Boron isotope fractionation in liquid chromatography with boron-specific resins as column packing material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oi, Takao; Shimazaki, Hiromi; Ishii, Reiko

    1997-07-01

    Boron-specific resins with n-methyl glucamine as the functional group were used as column packing material of liquid chromatography for boron isotope separation. The shapes of chromatograms in reverse breakthrough experiments were heavily dependent on the pH of the eluents, and there existed a pH value at which a chromatogram of the displacement type was realized nearly ideally. The value of the single-stage separation factor for the boron isotopes varied between 1.010 and 1.022, depending on the temperature and the form of the resins. The existence of the three-coordinate boron species in addition to the four-coordinate species in the resin phasemore » is suggested.« less

  6. A Collaborative Study: Determination of Mycotoxins in Corn, Peanut Butter, and Wheat Flour Using Stable Isotope Dilution Assay (SIDA) and Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS).

    PubMed

    Zhang, Kai; Schaab, Matthew R; Southwood, Gavin; Tor, Elizabeth R; Aston, Linda S; Song, Wenlu; Eitzer, Brian; Majumdar, Sanghamitra; Lapainis, Theodore; Mai, Huy; Tran, Kevin; El-Demerdash, Aref; Vega, Victor; Cai, Yanxuan; Wong, Jon W; Krynitsky, Alexandra J; Begley, Timothy H

    2017-08-23

    A collaborative study was conducted to evaluate stable isotope dilution assay (SIDA) and LC-MS/MS for the simultaneous determination of aflatoxins B 1 , B 2 , G 1 , and G 2 ; deoxynivalenol; fumonisins B 1 , B 2 , and B 3 ; ochratoxin A; HT-2 toxin; T-2 toxin; and zearalenone in foods. Samples were fortified with 12 13 C uniformly labeled mycotoxins ( 13 C-IS) corresponding to the native mycotoxins and extracted with acetonitrile/water (50:50 v/v), followed by centrifugation, filtration, and LC-MS/MS analysis. In addition to certified reference materials, the six participating laboratories analyzed corn, peanut butter, and wheat flour fortified with the 12 mycotoxins at concentrations ranging from 1.0 to 1000 ng/g. Using their available LC-MS/MS platform, each laboratory developed in-house instrumental conditions for analysis. The majority of recoveries ranged from 80 to 120% with relative standard derivations (RSDs) <20%. Greater than 90% of the average recoveries of the participating laboratories were in the range of 90-110%, with repeatability RSD r (within laboratory) < 10% and reproducibility RSD R (among laboratory) < 15%. All Z scores of the results of certified reference materials were between -2 and 2. Using 13 C-IS eliminated the need for matrix-matched calibration standards for quantitation, simplified sample preparation, and achieved simultaneous identification and quantitation of multiple mycotoxins in a simple LC-MS/MS procedure.

  7. Estimating total body water content in suckling and lactating llamas (Lama glama) by isotope dilution.

    PubMed

    Riek, Alexander; Gerken, Martina

    2010-08-01

    Total body water (TBW) in 17 suckling and six lactating llamas was estimated from isotope dilution at three different post natum and lactation stages using both (18)O and deuterium oxide (D(2)O). In total, 69 TBW measurements were undertaken. While TBW in lactating dams, expressed in kilogram, remained stable during the three measurement periods (91.8 +/- 15.0 kg), the body water fraction (TBW expressed in percent of body mass) increased slightly (P = 0.042) from 62.9% to 65.8%. In contrast, TBW (kilogram) in suckling llamas increased significantly (P < 0.001) with age and decreased slightly when expressed as a percentage of body mass (P = 0.016). Relating TBW to body mass across all animals yielded a highly significant regression equation (TBW in kilogram = 2.633 + 0.623 body mass in kilogram, P < 0.001, n = 69) explaining 99.5% of the variation. The water fraction instead decreased in a curve linear fashion with increasing body mass (TBW in percent of body mass = 88.23 body mass in kilogram(-0.064), P < 0.001, R (2) = 0.460). The present results on TBW can serve as reference values for suckling and lactating llamas, e.g., for the evaluation of fluid losses during disease. Additionally, the established regression equations can be used to predict TBW from body mass, providing that the body masses fall inside the range of masses used to derive the equations.

  8. Blank corrections for ramped pyrolysis radiocarbon dating of sedimentary and soil organic carbon.

    PubMed

    Fernandez, Alvaro; Santos, Guaciara M; Williams, Elizabeth K; Pendergraft, Matthew A; Vetter, Lael; Rosenheim, Brad E

    2014-12-16

    Ramped pyrolysis (RP) targets distinct components of soil and sedimentary organic carbon based on their thermochemical stabilities and allows the determination of the full spectrum of radiocarbon ((14)C) ages present in a soil or sediment sample. Extending the method into realms where more precise ages are needed or where smaller samples need to be measured involves better understanding of the blank contamination associated with the method. Here, we use a compiled data set of RP measurements of samples of known age to evaluate the mass of the carbon blank and its associated (14)C signature, and to assess the performance of the RP system. We estimate blank contamination during RP using two methods, the modern-dead and the isotope dilution method. Our results indicate that during one complete RP run samples are contaminated by 8.8 ± 4.4 μg (time-dependent) of modern carbon (MC, fM ∼ 1) and 4.1 ± 5.5 μg (time-independent) of dead carbon (DC, fM ∼ 0). We find that the modern-dead method provides more accurate estimates of uncertainties in blank contamination; therefore, the isotope dilution method should be used with caution when the variability of the blank is high. Additionally, we show that RP can routinely produce accurate (14)C dates with precisions ∼100 (14)C years for materials deposited in the last 10,000 years and ∼300 (14)C years for carbon with (14)C ages of up to 20,000 years.

  9. Determination of Os by isotope dilution-inductively coupled plasma-mass spectrometry with the combination of laser ablation to introduce chemically separated geological samples

    NASA Astrophysics Data System (ADS)

    Sun, Yali; Ren, Minghao; Xia, Xiaoping; Li, Congying; Sun, Weidong

    2015-11-01

    A method was developed for the determination of trace Os in geological samples by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) with the combination of chemical separation and preconcentration. Samples are digested using aqua regia in Carius tubes, and the Os analyte is converted into volatile OsO4, which is distilled and absorbed with HBr. The HBr solution is concentrated for further Os purification using the microdistillation technique. The purified Os is dissolved in 10 μl of 0.02% sucrose-0.005% H3PO4 solution and then evaporated on pieces of perfluoroalkoxy (PFA) film, resulting in the formation of a tiny object (< 3 × 104 μm2 superficial area). Using LA-ICP-MS measurements, the object can give Os signals at least 100 times higher than those provided by routine solution-ICP-MS while successfully avoiding the memory effect. The procedural blank and detection limit in the developed technique are 3.0 pg and 1.8 pg for Os, respectively when 1 g of samples is taken. Reference materials (RM) are analyzed, and their Os concentrations obtained by isotope dilution are comparable to reference or literature values. Based on the individual RM results, the precision is estimated within the range of 0.6 to 9.4% relative standard deviation (RSD), revealing that this method is applicable to the determination of trace Os in geological samples.

  10. Preparation of a sewage sludge laboratory quality control material for butyltin compounds and their determination by isotope-dilution mass spectrometry.

    PubMed

    Zuliani, Tea; Milačič, Radmila; Ščančar, Janez

    2012-05-01

    The characterisation of a laboratory quality control material (QCM) for dibutyltin (DBT) and tributyltin (TBT) in sewage sludge is described. The reference values were determined by the use of two different types of isotope-dilution mass spectrometry: gas chromatography-mass spectrometry and gas chromatography-inductively coupled plasma mass spectrometry. To avoid possible analytical errors such as non-quantitative extraction and species degradation during sample preparation, different extraction methods were tested (microwave- and ultrasound-assisted extraction and mechanical stirring). The reference values were based on the unweighted means of results from the homogenisation and characterisation studies. The reference values obtained were 1,553 ± 87 and 534 ± 38 ng Sn g(-1) for DBT and TBT, respectively. In the uncertainty budget estimation, the sample inhomogeneity and between-method imprecision were taken into account. The concentrations of DBT and TBT in QCM are similar to those in the harbour sediment certified reference material PACS-2. Likewise, the levels of DBT and TBT are in the range of these compounds normally present in sewage sludge worldwide. In the future, the QCM will be used for an intercomparison study on DBT and TBT in sewage sludge, and as a day-to-day QCM during studies concerning the application of sewage sludge as an additive to artificial soil or as a raw material in civil engineering construction.

  11. Validity of the methods to assess body fat in children and adolescents using multi-compartment models as the reference method: a systematic review.

    PubMed

    Silva, Danilo R P; Ribeiro, Alex S; Pavão, Fernando H; Ronque, Enio R V; Avelar, Ademar; Silva, Analiza M; Cyrino, Edilson S

    2013-01-01

    To analyze the validity of methods to assess body fat in children and adolescents using a systematic review. The search was conducted by two independent researchers using the MEDLINE, BioMed Central, SciELO and LILACS electronic databases. For inclusion, the articles should be written in English or Portuguese, and must have used multi-compartment models as the criterion measure of the model, with body fat measurement of whole body in non-athlete children and adolescents. A preliminary search resulted in 832 studies. After all selection steps were performed, 12 articles were included. The selected studies were published between 1997 and 2010, whose samples consisted of children and adolescents with levels of relative body fat ranging from 20.7% to 41.4%. The methods used were: dual energy X-ray absorptiometry (58.3%), isotope dilution (41.6%), skinfold thickness (33.3%), hydrostatic weighing (25%), bioelectrical impedance analysis (25%), air displacement plethysmography (16.6%), and total body electrical conductivity (8.3%). Based on the analysis of the studies, isotope dilution and air displacement plethysmography methods were the most reliable, despite the limited number of studies. As for clinical use or for population-based studies, the equation of Slaughter et al. (1998), which uses the triceps and subscapular skinfolds thickness, showed the best results for assessment of body fat in this population. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.

  12. Determination of six sulfonamide antibiotics, two metabolites and trimethoprim in wastewater by isotope dilution liquid chromatography/tandem mass spectrometry.

    PubMed

    Le-Minh, Nhat; Stuetz, Richard M; Khan, Stuart J

    2012-01-30

    A highly sensitive method for the analysis of six sulfonamide antibiotics (sulfadiazine, sulfathiazole, sulfapyridine, sulfamerazine, sulfamethazine and sulfamethoxazole), two sulfonamide metabolites (N(4)-acetyl sulfamethazine and N(4)-acetyl sulfamethoxazole) and the commonly co-applied antibiotic trimethoprim was developed for the analysis of complex wastewater samples. The method involves solid phase extraction of filtered wastewater samples followed by liquid chromatography-tandem mass spectral detection. Method detection limits were shown to be matrix-dependent but ranged between 0.2 and 0.4 ng/mL for ultrapure water, 0.4 and 0.7 ng/mL for tap water, 1.4 and 5.9 ng/mL for a laboratory-scale membrane bioreactor (MBR) mixed liquor, 0.7 and 1.7 ng/mL for biologically treated effluent and 0.5 and 1.5 ng/g dry weight for MBR activated sludge. An investigation of analytical matrix effects was undertaken, demonstrating the significant and largely unpredictable nature of signal suppression observed for variably complex matrices compared to an ultrapure water matrix. The results demonstrate the importance of accounting for such matrix effects for accurate quantitation, as done in the presented method by isotope dilution. Comprehensive validation of calibration linearity, reproducibility, extraction recovery, limits of detection and quantification are also presented. Finally, wastewater samples from a variety of treatment stages in a full-scale wastewater treatment plant were analysed to illustrate the effectiveness of the method. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Sensitive analysis of steroid estrogens and bisphenol a in small volumes of water using isotope-dilution ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Chang, Hong; Shen, Xiaoyan; Shao, Bing; Wu, Fengchang

    2018-04-01

    An isotope-dilution ultra-performance liquid chromatography-electrospray tandem mass spectrometry method combined with dansylation was established to sensitively quantify four steroid estrogens (estrone, 17α-estradiol, 17β-estradiol and 17α-ethynylestradiol) and bisphenol A in sewage influent and effluent. A simple hexane extraction was performed from a small volume (10 mL), followed by dansyl chloride derivatization and purification with a silica cartridge. The method effectively reduced the matrix effects in sample extract and permitted the selective and sensitive determination of target compounds from complicated matrices. The detection limits of the method for steroid estrogens were 0.20-0.90 ng L -1 in influent and 0.10-0.20 ng L -1 in effluent samples. For bisphenol A, the limits detection of the method were 20 and 0.80 for influent and effluent samples, respectively. Recoveries of 85%-96% were observed in all matrices. The method was applied to analyze residual estrogens and bisphenol A in sewage influent and effluent samples from Beijing, China. The concentrations of bisphenol A (636-1200 ng L -1 ) were up to 250 times higher than those of steroid estrogens. Estrone was the dominant estrogen in influent and effluent samples, while similar concentrations of 17α-estradiol and 17β-estradiol were detected in all samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Quantitation of DNA adducts by stable isotope dilution mass spectrometry

    PubMed Central

    Tretyakova, Natalia; Goggin, Melissa; Janis, Gregory

    2012-01-01

    Exposure to endogenous and exogenous chemicals can lead to the formation of structurally modified DNA bases (DNA adducts). If not repaired, these nucleobase lesions can cause polymerase errors during DNA replication, leading to heritable mutations potentially contributing to the development of cancer. Due to their critical role in cancer initiation, DNA adducts represent mechanism-based biomarkers of carcinogen exposure, and their quantitation is particularly useful for cancer risk assessment. DNA adducts are also valuable in mechanistic studies linking tumorigenic effects of environmental and industrial carcinogens to specific electrophilic species generated from their metabolism. While multiple experimental methodologies have been developed for DNA adduct analysis in biological samples – including immunoassay, HPLC, and 32P-postlabeling – isotope dilution high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) generally has superior selectivity, sensitivity, accuracy, and reproducibility. As typical DNA adducts concentrations in biological samples are between 0.01 – 10 adducts per 108 normal nucleotides, ultrasensitive HPLC-ESI-MS/MS methodologies are required for their analysis. Recent developments in analytical separations and biological mass spectrometry – especially nanoflow HPLC, nanospray ionization MS, chip-MS, and high resolution MS – have pushed the limits of analytical HPLC-ESI-MS/MS methodologies for DNA adducts, allowing researchers to accurately measure their concentrations in biological samples from patients treated with DNA alkylating drugs and in populations exposed to carcinogens from urban air, drinking water, cooked food, alcohol, and cigarette smoke. PMID:22827593

  15. Direct determination of fatty acid esters of 3-chloro-1, 2-propanediol in edible vegetable oils by isotope dilution - ultra high performance liquid chromatography - triple quadrupole mass spectrometry.

    PubMed

    Li, Heli; Chen, Dawei; Miao, Hong; Zhao, Yunfeng; Shen, Jianzhong; Wu, Yongning

    2015-09-04

    A selective and sensitive ultra-high performance liquid chromatography - triple quadrupole mass spectrometry (UHPLC-MS/MS) method coupled with matrix solid phase dispersion (MSPD) extraction was developed for the direct determination of fatty acid esters of 3-chloro-1,2-propanediol (3-MCPD esters) in edible vegetable oils. The method integrated the isotope dilution technique, MSPD extraction and UHPLC - MS/MS analysis with multi-reaction monitoring mode (MRM). Matrix-matched calibration curves showed good linearity within the range of 0.01-10mgL(-1) with the correlation coefficient not less than 0.999. Limits of detection (LODs) and limit of quantification (LOQs) of the 3-MCPD esters fell into the range of 0.0001-0.02mgkg(-1) and 0.0004-0.05mgkg(-1), respectively. The recoveries for the spiked extra virgin olive oils ranged from 94.4% to 108.3%, with the relative standard deviations (RSD) ranging from 0.6% to 10.5%. The method was applied for the oil sample (T2642) of the official Food Analysis Performance Assessment Scheme (FAPAS) in 2014 and other real samples from supermarket, and the results showed that the present method was comparative to the gas chromatography-mass spectrometry (GC-MS) method based on the improved German Society for Fat Science (DGF) standard method C-III 18 (09) except for palm oil. Copyright © 2015. Published by Elsevier B.V.

  16. Existing and emerging technologies for measuring stable isotope labelled retinol in biological samples: isotope dilution analysis of body retinol stores.

    PubMed

    Preston, Tom

    2014-01-01

    This paper discusses some of the recent improvements in instrumentation used for stable isotope tracer measurements in the context of measuring retinol stores, in vivo. Tracer costs, together with concerns that larger tracer doses may perturb the parameter under study, demand that ever more sensitive mass spectrometric techniques are developed. GCMS is the most widely used technique. It has high sensitivity in terms of sample amount and uses high resolution GC, yet its ability to detect low isotope ratios is limited by background noise. LCMSMS may become more accessible for tracer studies. Its ability to measure low level stable isotope tracers may prove superior to GCMS, but it is isotope ratio MS (IRMS) that has been designed specifically for low level stable isotope analysis through accurate analysis of tracer:tracee ratios (the tracee being the unlabelled species). Compound-specific isotope analysis, where GC is interfaced to IRMS, is gaining popularity. Here, individual 13C-labelled compounds are separated by GC, combusted to CO2 and transferred on-line for ratiometric analysis by IRMS at the ppm level. However, commercially-available 13C-labelled retinol tracers are 2 - 4 times more expensive than deuterated tracers. For 2H-labelled compounds, GC-pyrolysis-IRMS has now become more generally available as an operating mode on the same IRMS instrument. Here, individual compounds are separated by GC and pyrolysed to H2 at high temperature for analysis by IRMS. It is predicted that GC-pyrolysis-IRMS will facilitate low level tracer procedures to measure body retinol stores, as has been accomplished in the case of fatty acids and amino acids. Sample size requirements for GC-P-IRMS may exceed those of GCMS, but this paper discusses sample preparation procedures and predicts improvements, particularly in the efficiency of sample introduction.

  17. Submicrometer Organic Grains: Widespread Constituents of the Early Solar System

    NASA Technical Reports Server (NTRS)

    Messenger, Scott; Nakamuri-Messenger, Keiko; Keller, Lindsay; Matrajt, Graciela; Clemett, Simon; Ito, Motoo

    2007-01-01

    Primitive meteorites and interplanetary dust particles (IDPs) contain remants of interstellar organic matter, marked by anomalous H and N isotopic ratios. These isotopic anomalies are attributed to mass fractionation during chemical reactions at cryogenic temperatures (10-100K) in a cold molecular cloud. Significant variations in the chemistry and isotopic compositions of organic compounds within and between these samples suggest varying histories of alteration and dilution of the presolar components. Recent studies have reported large H and N isotopic anomalies preserved in sub-m organic inclusions in both meteorites and IDPs. In the Tagish Lake meteorite, the largest H and N isotopic anomalies are associated with sub-m, hollow organic globules. The common physical, chemical, and isotopic characteristics of these globules suggest that they formed before being incorporated into their parent meteorite. These organic globules probably originated as organic ice coatings that formed on preexisting ice or mineral grains in a cold molecular cloud. Radiation driven photochemistry may have processed them into refractory organic grains. This model implies that submicrometer organic grains were widely distributed throughout the solar nebula during the epoch of planet formation. Submicrometer organic particles were detected by the Giotto and Vega encounters with comet Halley, termed CHON particles based on their major element chemistry. The first direct samples of cometary dust (comet Wild-2) were returned by the Stardust spacecraft in January 2006. These samples exhibit widely varying, fine grained mineralogy similar to anhydrous IDPs, including submicrometer carbonaceous grains. The submicrometer organic grains from comet Wild-2 exhibit H and N isotopic anomalies of similar magnitude to those commonly observed in primitive meteorites and IDPs. Isotopically anomalous, submicrometer organic grains have now been observed in meteorites, IDPs, the Oort-cloud comet Halley, and the Kuiper-belt comet Wild-2, suggesting that such grains were prevalent throughout the protoplanetary disk.

  18. A dendrimer chiroptical switch based on the reversible intramolecular photoreaction of anthracene and benzene rings.

    PubMed

    Liu, Wenjie; Cao, Derong; Peng, Jinan; Zhang, Hong; Meier, Herbert

    2010-08-02

    A series of Fréchet-type dendrimers with 9-benzyloxymethylanthracene cores were synthesized and characterized. The chiral source for the dendrimers was an (S)-2-methyl-1-butoxy group in the 3-position of the benzene ring. Irradiation at 366 nm of a dilute benzene solution led to the formation of two diastereomers (1:1) through a quantitative intramolecular [4pi+4pi] cycloaddition between the central anthracene ring and the neighboring benzene ring. The process can be reversed with 254 nm UV light or heat. The benzene rings in the dendrons work as a light-harvesting system. The optical rotation values measured for the reversible process showed fatigue resistance. Thus, a promising new type of chiroptical switch has been created that has optical rotation values as output signals.

  19. On the atomic structure of liquid Ni-Si alloys: a neutron diffraction study

    NASA Astrophysics Data System (ADS)

    Gruner, S.; Marczinke, J.; Hennet, L.; Hoyer, W.; Cuello, G. J.

    2009-09-01

    The atomic structure of the liquid NiSi and NiSi2 alloys is investigated by means of neutron diffraction experiments with isotopic substitution. From experimental data-sets obtained using four Ni isotopes, partial structure factors and pair correlation functions are obtained by applying a reverse Monte Carlo modelling approach. Both alloys were found to exhibit a strong tendency to hetero-coordination within the first coordination shell. In particular, covalent Si-Si bonds with somewhat greater distances seem to influence the structure of the liquid NiSi alloy.

  20. On the atomic structure of liquid Ni-Si alloys: a neutron diffraction study.

    PubMed

    Gruner, S; Marczinke, J; Hennet, L; Hoyer, W; Cuello, G J

    2009-09-23

    The atomic structure of the liquid NiSi and NiSi(2) alloys is investigated by means of neutron diffraction experiments with isotopic substitution. From experimental data-sets obtained using four Ni isotopes, partial structure factors and pair correlation functions are obtained by applying a reverse Monte Carlo modelling approach. Both alloys were found to exhibit a strong tendency to hetero-coordination within the first coordination shell. In particular, covalent Si-Si bonds with somewhat greater distances seem to influence the structure of the liquid NiSi alloy.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eppich, Gary R.; Williams, Ross W.; Gaffney, Amy M.

    Here, age dating of nuclear material can provide insight into source and suspected use in nuclear forensic investigations. We report here a method for the determination of the date of most recent chemical purification for uranium materials using the 235U- 231Pa chronometer. Protactinium is separated from uranium and neptunium matrices using anion exchange resin, followed by sorption of Pa to an SiO 2 medium. The concentration of 231Pa is measured by isotope dilution mass spectrometry using 233Pa spikes prepared from an aliquot of 237Np and calibrated in-house using the rock standard Table Mountain Latite and the uranium isotopic standard U100.more » Combined uncertainties of age dates using this method are 1.5 to 3.5 %, an improvement over alpha spectrometry measurement methods. Model ages of five uranium standard reference materials are presented; all standards have concordant 235U- 231Pa and 234U- 230Th model ages.« less

  2. Collaborative trial validation study of two methods, one based on high performance liquid chromatography-tandem mass spectrometry and on gas chromatography-mass spectrometry for the determination of acrylamide in bakery and potato products.

    PubMed

    Wenzl, Thomas; Karasek, Lubomir; Rosen, Johan; Hellenaes, Karl-Erik; Crews, Colin; Castle, Laurence; Anklam, Elke

    2006-11-03

    A European inter-laboratory study was conducted to validate two analytical procedures for the determination of acrylamide in bakery ware (crispbreads, biscuits) and potato products (chips), within a concentration range from about 20 microg/kg to about 9000 microgg/kg. The methods are based on gas chromatography-mass spectrometry (GC-MS) of the derivatised analyte and on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) of native acrylamide. Isotope dilution with isotopically labelled acrylamide was an integral part of both methods. The study was evaluated according to internationally accepted guidelines. The performance of the HPLC-MS/MS method was found to be superior to that of the GC-MS method and to be fit-for-the-purpose.

  3. Search for extinct natural radioactivity of Pb205 via thallium-isotope anomalies in chondrites and lunar soil.

    NASA Technical Reports Server (NTRS)

    Huey, J. M.; Kohman, T. P.

    1972-01-01

    Thallium and Pb204 contents were determined by stable-isotope-dilution analysis in 16 chondrites, one achondrite, and Apollo 11 and 12 lunar fines. Meteoritic thallium contents vary over a large range, 0.02 to 100 ppb, corresponding to the fact that thallium is a highly fractionated volatile element. Lunar thallium contents are less than 5 ppb. The Tl205/Tl203 ratio was determined in most of the samples, with precision ranging from 0.03% to several percent depending mainly on the amount of thallium present. No variations from the terrestrial ratio were observed. The chondritic isochron slope for Pb205 (13.8-m.y. half-life) is less than or equal to 0.00009 (99% confidence level), corresponding to an interval of at least 60 m.y. and possibly exceeding 120 m.y. between the termination of s-process nucleosynthesis and the lead-thallium fractionations.

  4. Geochemical evaluation of the geothermal resources in the San Marcos region, Guatemala

    USGS Publications Warehouse

    Fournier, R.O.; Hanshaw, B.B.

    1986-01-01

    The chemical and isotopic compositions of hot springs in the San Marcos region of Guatemala are internally consistent with a hydrologic model in which a deep 240??C reservoir and one or more shallow 195-200??C reservoirs are present. Variations in hot-spring water compositions results from a combination of boiling, mixing with cold, dilute water, and chemical re-equilibration with decreasing temperature. The recharge water for the deep 240??C reservoir is isotopically heavier than the local meteoric water and probably comes from many kilometers to the west or southwest. The water in the shallow reservoir is a mixture of the 240??C water with about 20 ?? 5% of cold, locally derived meteoric water. After mixing, the water in the shallow reservoir re-equilibrates with reservoir rock at 195-200??C. In some places additional mixing with cold water occurs after water leaves the shallow reservoir. ?? 1986.

  5. Geologic map showing springs rich in carbon dioxide or or chloride in California

    USGS Publications Warehouse

    Barnes, Ivan; Irwin, William P.; Gibson, H.A.

    1975-01-01

    Carbon dioxide- and chloride-rich springs occur in all geologic provinces in California, but are most abundant in the Coast Ranges and the Great Valley. The carbon-dioxide-rich springs issue mainly from Franciscan terrane; they also are rich in boron and are of the metamorphic type (White, 1957). Based on isotopic data, either the carbon dioxide or the water, or both, may be of metamorphic origin. Because of high magnesium values, the water of many of the carbon-dioxide-rich springs is thought to have passed through serpentinite. The chloride-rich waters are most common in rocks of the Great Valley sequence. Nearly all are more dilute than present-day sea water. The similarity in isotopic compositions of the metamorphic carbon-dioxide-rich water and the chloride-rich water may indicate a similar extent of water-rock interaction.

  6. Airborne measurements of sulfur dioxide, dimethyl sulfide, carbon disulfide, and carbonyl sulfide by isotope dilution gas chromatography/mass spectrometry

    NASA Technical Reports Server (NTRS)

    Bandy, Alan R.; Thornton, Donald C.; Driedger, Arthur R., III

    1993-01-01

    A gas chromatograph/mass spectrometer is described for determining atmospheric sulfur dioxide, carbon disulfide, dimethyl sulfide, and carbonyl sulfide from aircraft and ship platforms. Isotopically labelled variants of each analyte were used as internal standards to achieve high precision. The lower limit of detection for each species for an integration time of 3 min was 1 pptv for sulfur dioxide and dimethyl sulfide and 0.2 pptv for carbon disulfide and carbonyl sulfide. All four species were simultaneously determined with a sample frequency of one sample per 6 min or greater. When only one or two species were determined, a frequency of one sample per 4 min was achieved. Because a calibration is included in each sample, no separate calibration sequence was needed. Instrument warmup was only a few minutes. The instrument was very robust in field deployments, requiring little maintenance.

  7. Reduction of ion transport and turbulence via dilution with nitrogen and neon injection in C-Mod deuterium plasmas

    NASA Astrophysics Data System (ADS)

    Porkolab, M.; Ennever, P.; Baek, S. G.; Creely, A. J.; Edlund, E. M.; Hughes, J.; Rice, J. E.; Rost, J. C.; White, A. E.; Reinke, M. L.; Staebler, G.; Candy, J.; Alcator C-Mod Team

    2016-10-01

    Recent experiments on C-Mod ohmic plasmas and gyrokinetic studies indicated that dilution of deuterium plasmas by injection of nitrogen decreased the ion diffusivity and may also alter the direction of intrinsic toroidal rotation. Simulations with TGLF and GYRO showed that dilution of deuterium ions in low density (LOC) plasmas increased the critical ion temperature gradient, while in high density (SOC) plasmas it decreased the stiffness. The density fluctuation spectrum measured in low q95 plasmas with Phase Contrast Imaging (PCI), and corroborated with spatially localized reflectometer measurements show a reduction of turbulence near r/a = 0.8 with kρs <= 1, in agreement with modeling predictions in this region where the ion turbulence is well above marginal stability. Measurements also indicate that reversal of the toroidal rotation direction near the SOC-LOC transition may depend on ion collisionality rather than that of electrons. New experiments with neon seeding, which may be more relevant to ITER than with nitrogen seeding, show similar results. The impact of dilution on Te turbulence as measured with CECE diagnostic will also be presented. Supported by US DOE Awards DE-FG02-94-ER54235 and DE-FC02-99-ER54512.

  8. A cost-effective approach to produce 15N-labelled amino acids employing Chlamydomonas reinhardtii CC503.

    PubMed

    Nicolás Carcelén, Jesús; Marchante-Gayón, Juan Manuel; González, Pablo Rodríguez; Valledor, Luis; Cañal, María Jesús; Alonso, José Ignacio García

    2017-08-18

    The use of enriched stable isotopes is of outstanding importance in chemical metrology as it allows the application of isotope dilution mass spectrometry (IDMS). Primary methods based on IDMS ensure the quality of the analytical measurements and traceability of the results to the international system of units. However, the synthesis of isotopically labelled molecules from enriched stable isotopes is an expensive and a difficult task. Either chemical and biochemical methods to produce labelled molecules have been proposed, but so far, few cost-effective methods have been described. The aim of this study was to use the microalgae Chlamydomonas reinhardtii to produce, at laboratory scale, 15 N-labelled amino acids with a high isotopic enrichment. To do that, a culture media containing 15 NH 4 Cl was used. No kinetic isotope effect (KIE) was observed. The labelled proteins biosynthesized by the microorganism were extracted from the biomass and the 15 N-labelled amino acids were obtained after a protein hydrolysis with HCl. The use of the wall deficient strain CC503 cw92 mt+ is fit for purpose, as it only assimilates ammonia as nitrogen source, avoiding isotope contamination with nitrogen from the atmosphere or the reagents used in the culture medium, and enhancing the protein extraction efficiency compared to cell-walled wild type Chlamydomonas. The isotopic enrichment of the labelled amino acids was calculated from their isotopic composition measured by gas chromatography mass spectrometry (GC-MS). The average isotopic enrichment for the 16 amino acids characterized was 99.56 ± 0.05% and the concentration of the amino acids in the hydrolysate ranged from 18 to 90 µg/mL. Previously reported biochemical methods to produce isotopically labelled proteins have been applied in the fields of proteomics and fluxomics. For these approaches, low amounts of products are required and the isotopic enrichment of the molecules has never been properly determined. So far, only 13 C-labelled fatty acids have been isolated from labelled microalga biomass as valuable industrial products. In this study, we propose Chlamydomonas reinhardtii CC503 as a feasible microorganism and strain to produce labelled biomass from which a standard containing sixteen 15 N-labelled amino acids could be obtained.

  9. Assay of S for Quantitation of PEG and TNF Ligated Au Nanoparticles using ID-HR-MC-ICP-MS

    NASA Astrophysics Data System (ADS)

    Mann, J. L.; Vocke, R. D.; Newman, J. D.; Kelly, W. R.

    2009-12-01

    The use of nanomaterials in medicine has recently increased with the discovery that these materials can deliver drugs to specific sites within the body. An active area of nanomedicine involves the use of gold nanoparticles (AuNPs) as a delivery platform for anti-cancer agents such as tumor necrosis factor-α (TNF-α). TNF-α molecules attack the blood vessels in a tumor causing them to hemorrhage profusely. TNF-α is also highly toxic to normal cells, making targeted delivery to the tumor site crucial. AuNPs ensure the ligated TNF-α is delivered to its appropriate target, mitigating systemic toxicity. Additionally, coating AuNPs with the surface modifier polyethylene glycol (PEG) promotes bioavailability and biodistribution of TNF-α by preventing protein binding and bodily uptake thereby increasing the lifetime in the bloodstream. The FDA will likely mandate all nanotechnologies of this sort undergo quality control to ensure the nanoplatforms are modified with approximately the same number of drug molecules and other surface modifiers. Quality control methods, such as visible spectroscopy, can be used to qualitatively assess the total amounts of TNF-α and PEG on AuNPs, however, these methods need to be validated via calibration by an absolute technique. The sulfur content can be used as a proxy for both PEG and TNF-α concentrations because of the presence of at least one thiol in each of the ligands. The goal of this work was to provide a benchmark for future spectroscopic results by providing an accurate assessment of the TNF-α and PEG concentrations through the accurate quantitation of S. The sulfur concentration was assayed using isotope dilution (ID) combined with high resolution multi-collector inductively coupled plasma mass spectrometry (HR-MC-ICPMS). The measurement of S using ICPMS instrumentation is challenging because 1) molecular interferences (e.g. oxides, nitrides, and hydrides) exist on each of the S isotopes and 2) the need to perform the measurements in high-resolution (HR) mode to resolve these interferences reduces the overall signal intensity. To further reduce the effects of the interferences and limit the signal attentuation resulting from running in HR mode, an Aridus II desolvator was used to introduce the sample as a dry aerosol. The signal intensities obtained on the most abundant isotope mass 32 are typically 6 x 10-11 A per ug S/g solution. A small sulfur hydride, however, remains 3 x 10-14 A at mass 33S. By using a 33S enriched spike for isotope dilution, the overall effect of the hydride on mass 33 is significantly reduced (<0.2 %). The samples and standards were spiked in both a 1:1 and 2:1 ratio 32S:33S and the 32S/34S ratio was used as the internal normalization ratio for mass bias determination. Using an iterative procedure, the mass bias and measured 32S/33S ratios were successively corrected until the values converged. This calculation removes the spike contribution to the sample to obtain the mass bias corrected 33S/32S. The corrected 33S/32S ratios were then used in the isotope dilution calculation for S quantitation. Preliminary results on pure sulfur solutions and PEG solutions at a concentration of approximately 1 ppm S (≈ 38 nM PEG/g), show comparable results with rsd’s in the 0.5 to 1% range.

  10. ASSESSING NITROGEN SOURCES IN LAKES WITH MUSSEL STABLE ISOTOPE RATIOS

    EPA Science Inventory

    Despite progress made in the past several decades towards limiting nutrient inputs, human-induced eutrophication in lakes, ponds, and reservoirs continues to be of concern. Although many successes in reversing the effects of nutrient enrichment were realized by regulating phospho...

  11. Chemical Sample Processing for Combined Selenium Isotope and Selenium-Tellurium Elemental Investigation of the Earth's Igneous Reservoirs

    NASA Astrophysics Data System (ADS)

    Yierpan, Aierken; König, Stephan; Labidi, Jabrane; Kurzawa, Timon; Babechuk, Michael G.; Schoenberg, Ronny

    2018-02-01

    The redox-sensitive, chalcophile, and volatile Se stable isotope system offers new perspectives to investigate the origin and evolution of terrestrial volatiles and the roles of magmatic and recycling processes in the development of the redox contrast between Earth's reservoirs. Selenium isotope systematics become more robust in a well-constrained petrogenetic context as can be inferred from Se-Te elemental signatures of sulfides and igneous rocks. In this study, we present a high-yield chemical sample processing method that allows the determination of Se-Te concentrations and Se isotope composition from the same sample digest of silicate rocks by hydride generation isotope dilution (ID) quadrupole inductively coupled plasma mass spectrometry (ICP-MS) and double spike (DS) multicollector (MC)-ICP-MS, respectively. Our procedure yields ˜80% Se-Te recoveries with quantitative separation of relevant interfering elements such as Ge and HG-buffering metals. Replicate analyses of selected international reference materials yield uncertainties better than 0.11‰ (2 s.d.) on δ82/76Se and 3% (r.s.d.) on Se concentration for DS MC-ICP-MS determinations for as low as ˜10 ng sample Se. The precision of Se-Te concentration measurements by ID ICP-MS is better than 3% and 5% (r.s.d.) for total amounts of ˜0.5-1 ng Se and ˜0.2-0.5 ng Te, respectively. The basaltic reference materials have variable Se-Te contents, but their δ82/76Se values are rather uniform (on average 0.23 ± 0.14‰; 2 s.d.) and different from the chondritic value. This altogether provides the methodology and potential to extend the limited data set of coupled Se isotope and Se-Te elemental systematics of samples relevant to study the terrestrial igneous inventory.

  12. Automated solid-phase extraction coupled online with HPLC-FLD for the quantification of zearalenone in edible oil.

    PubMed

    Drzymala, Sarah S; Weiz, Stefan; Heinze, Julia; Marten, Silvia; Prinz, Carsten; Zimathies, Annett; Garbe, Leif-Alexander; Koch, Matthias

    2015-05-01

    Established maximum levels for the mycotoxin zearalenone (ZEN) in edible oil require monitoring by reliable analytical methods. Therefore, an automated SPE-HPLC online system based on dynamic covalent hydrazine chemistry has been developed. The SPE step comprises a reversible hydrazone formation by ZEN and a hydrazine moiety covalently attached to a solid phase. Seven hydrazine materials with different properties regarding the resin backbone, pore size, particle size, specific surface area, and loading have been evaluated. As a result, a hydrazine-functionalized silica gel was chosen. The final automated online method was validated and applied to the analysis of three maize germ oil samples including a provisionally certified reference material. Important performance criteria for the recovery (70-120 %) and precision (RSDr <25 %) as set by the Commission Regulation EC 401/2006 were fulfilled: The mean recovery was 78 % and RSDr did not exceed 8 %. The results of the SPE-HPLC online method were further compared to results obtained by liquid-liquid extraction with stable isotope dilution analysis LC-MS/MS and found to be in good agreement. The developed SPE-HPLC online system with fluorescence detection allows a reliable, accurate, and sensitive quantification (limit of quantification, 30 μg/kg) of ZEN in edible oils while significantly reducing the workload. To our knowledge, this is the first report on an automated SPE-HPLC method based on a covalent SPE approach.

  13. Use of high-performance liquid chromatography with diode array detection coupled to electrospray-Qq-time-of-flight mass spectrometry for the direct characterization of the phenolic fraction in organic commercial juices.

    PubMed

    Rodríguez-Medina, I C; Segura-Carretero, A; Fernández-Gutiérrez, A

    2009-06-05

    We have developed a direct method for the qualitative analysis of polyphenols in commercial organic fruit juices. The juices were diluted with water (50/50), filtered and directly injected. The analysis of phenolic compounds was carried out by reversed-phase high-performance liquid chromatography (RP-HPLC) coupled to photodiode array detection (DAD) and electrospray ionisation-Qq-time-of-flight mass spectrometry (ESI-Qq-TOF-MS). A unique gradient program has been optimized for the separation of several phenolic classes and the analysis time was only 5 min. The fruit juice samples were successfully analysed in positive and negative ionisation modes. In positive mode the anthocyanins were identified whereas the vast majority of polyphenols were identified using the negative ionisation mode. The sensitivity, together with mass accuracy and true isotopic pattern of the Qq-TOF-MS, allowed the identification of the phenolic compounds. Moreover, the advantage of the proposed method is the combined search of MS and MS/MS spectra, which improves the identification of compounds considerably, reducing ambiguities and false positive hits. Therefore the total fragmentation of the compound ion leading to the aglycone ion or other fragments was corroborated by MS-MS. The method was successfully employed to characterize diverse phenolic families in commercially available organic juices from four different fruits and consequently could be used in the future for the quantification purposes to compare different content of polyphenols in juices.

  14. A validated ultra-high-performance liquid chromatography-tandem mass spectrometry method for the selective analysis of free and total folate in plasma and red blood cells.

    PubMed

    Kiekens, Filip; Van Daele, Jeroen; Blancquaert, Dieter; Van Der Straeten, Dominique; Lambert, Willy E; Stove, Christophe P

    2015-06-12

    A stable isotope dilution LC-MS/MS method is the method of choice for the selective quantitative determination of several folate species in clinical samples. By implementing an integrated approach to determine both the plasma and red blood cell (RBC) folate status, the use of consumables and time remains limited. Starting from a single 300μl whole blood sample, the folate status in plasma and RBCs can be determined after separating plasma and RBCs and sequential washing of the latter with isotonic buffer, followed by reproducible lysis using an ammonium-based buffer. Acidification combines both liberation of protein bound folates and protein precipitation. Sample cleanup is performed using a 96-well reversed-phase solid-phase extraction procedure, similar for both plasma and RBC samples. Analyses are performed by UHPLC-MS/MS. Method validation was successfully performed based on EMA-guidelines and encompassed selectivity, carry-over, linearity, accuracy, precision, recovery, matrix effect and stability. Plasma and RBC folates could be quantified in the range of 1-150nmol/l and 5-1500nmol/l, respectively. This method allows for the determination of 6 folate monoglutamates in both plasma and RBCs. It can be used to determine short and long term folate status in both normal and severely deficient subjects in a single analytical sequence. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Quantification of γ-Aminobutyric Acid in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    PubMed

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of γ-aminobutyric acid (GABA), a major inhibitory neurotransmitter in human cerebrospinal fluid (CSF) as a clinical diagnostic test. Determination of GABA in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Analysis of free and total GABA requires two individual sample preparations and mass spectrometry analyses. Free GABA in CSF is determined by a 1:2 dilution with internal standard (GABA-D2) and injected directly onto the HPLC-ESI-MS/MS system. Determination of total GABA in CSF requires additional sample preparation in order to hydrolyze all the bound GABA in the sample to the free form. This requires hydrolyzing the sample by boiling in acidic conditions (hydrochloric acid) for 4 h. The sample is then further diluted 1:10 with a 90 % acetonitrile/0.1 % formic acid solution and injected into the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve and is linear from 6 nM to 1000 nM and 0.63 μM to 80 μM for free and total GABA, respectively.

  16. Insights into the Key Aroma Compounds in Mango (Mangifera indica L. 'Haden') Fruits by Stable Isotope Dilution Quantitation and Aroma Simulation Experiments.

    PubMed

    Munafo, John P; Didzbalis, John; Schnell, Raymond J; Steinhaus, Martin

    2016-06-01

    Thirty-four aroma-active compounds, previously identified with high flavor dilution factors by application of an aroma extract dilution analysis, were quantified in tree-ripened fruits of mango (Mangifera indica L. 'Haden'). From the results, the odor activity value (OAV) was calculated for each compound as the ratio of its concentration in the mangoes to its odor threshold in water. OAVs > 1 were obtained for 24 compounds, among which ethyl 2-methylbutanoate (fruity; OAV 2100), (3E,5Z)-undeca-1,3,5-triene (pineapple-like; OAV 1900), ethyl 3-methylbutanoate (fruity; OAV 1600), and ethyl butanoate (fruity; OAV 980) were the most potent, followed by (2E,6Z)-nona-2,6-dienal (cucumber-like), ethyl 2-methylpropanoate (fruity), (E)-β-damascenone (cooked apple-like), ethyl hexanoate (fruity), 4-hydroxy-2,5-dimethyl-3(2H)-furanone (caramel-like), 3-methylbut-2-ene-1-thiol (sulfurous), γ-decalactone (peach-like), β-myrcene (terpeny), (3Z)-hex-3-enal (green), 4-methyl-4-sulfanylpentan-2-one (tropical fruit-like), and ethyl octanoate (fruity). Aroma simulation and omission experiments revealed that these 15 compounds, when combined in a model mixture in their natural concentrations, were able to mimic the aroma of the fruits.

  17. Analysis of polonium-210 in food products and bioassay samples by isotope-dilution alpha spectrometry.

    PubMed

    Lin, Zhichao; Wu, Zhongyu

    2009-05-01

    A rapid and reliable radiochemical method coupled with a simple and compact plating apparatus was developed, validated, and applied for the analysis of (210)Po in variety of food products and bioassay samples. The method performance characteristics, including accuracy, precision, robustness, and specificity, were evaluated along with a detailed measurement uncertainty analysis. With high Po recovery, improved energy resolution, and effective removal of interfering elements by chromatographic extraction, the overall method accuracy was determined to be better than 5% with measurement precision of 10%, at 95% confidence level.

  18. Carbon and nitrogen stable isotope analysis of three types of oyster tissue in an impacted estuary

    NASA Astrophysics Data System (ADS)

    Piola, Richard F.; Moore, Stephanie K.; Suthers, Iain M.

    2006-01-01

    The stable isotope ratios of carbon ( δ13C) and nitrogen ( δ15N) of the muscle, ctenidia and viscera of the Sydney rock oyster, Saccostrea glomerata, showed the dilution and assimilation of tertiary treated sewage along an estuarine gradient. The enriched 15N values of oyster ctenidia and viscera from within 50 m of the sewage outfall indicated the use of 15N-enriched tertiary treated sewage effluent (16 ± 2.3‰) as a nutrient source. The effect of sewage nitrogen on oyster δ15N was localised, with oysters 5 km upstream and downstream of the outfall not significantly enriched. Viscera δ15N was most sensitive to sewage nutrients and δ13C significantly defined an ocean-to-estuarine gradient. High variance in isotope ratios of viscera compromised its use as an indicator of anthropogenic nutrients, and this also reduced the utility of whole-body stable isotope ratios. Ctenidia was the most useful indicator tissue of sewage discharge at the scale of this study, being consistently and significantly enriched in δ15N close to the sewage outfall and δ13C clearly defined an estuarine gradient with less internal variability than viscera. Muscle δ15N was least sensitive to sewage effluent and showed the least variability, making it more suited to investigations of anthropogenic nutrient enrichment over larger spatio-temporal scales.

  19. Thermal effects on rare earth element and strontium isotope chemistry in single conodont elements

    NASA Astrophysics Data System (ADS)

    Armstrong, H. A.; Pearson, D. G.; Griselin, M.

    2001-02-01

    A low-blank, high sensitivity isotope dilution, ICP-MS analytical technique has been used to obtain REE abundance data from single conodont elements weighing as little as 5 μg. Sr isotopes can also be measured from the column eluants enabling Sr isotope ratios and REE abundance to be determined from the same dissolution. Results are comparable to published analyses comprising tens to hundreds of elements. To study the effects of thermal metamorphism on REE and strontium mobility in conodonts, samples were selected from a single bed adjacent to a basaltic dyke and from the internationally used colour alteration index (CAI) "standard set." Our analyses span the range of CAI 1 to 8. Homogeneous REE patterns, "bell-shaped" shale-normalised REE patterns are observed across the range of CAI 1 to 6 in both sample sets. This pattern is interpreted as the result of adsorption during early diagenesis and could reflect original seawater chemistry. Above CAI 6 REE patterns become less predictable and perturbations from the typical REE pattern are likely to be due to the onset of apatite recrystallisation. Samples outside the contact aureole of the dyke have a mean 87Sr/ 86Sr ratio of 0.708165, within the broad range of published mid-Carboniferous seawater values. Our analysis indicates conodonts up to CAI 6 record primary geochemical signals that may be a proxy for ancient seawater.

  20. Multivariate Stable Isotope Analysis to Determine Linkages between Benzocaine Seizures

    NASA Astrophysics Data System (ADS)

    Kemp, H. F.; Meier-Augenstein, W.; Collins, M.; Salouros, H.; Cunningham, A.; Harrison, M.

    2012-04-01

    In July 2010, a woman was jailed for nine years in the UK after the prosecution successfully argued that attempting to import a cutting agent was proof of involvement in a conspiracy to supply Cocaine. That landmark ruling provided law enforcement agencies with much greater scope to tackle those involved in this aspect of the drug trade, specifically targeting those importing the likes of benzocaine or lidocaine. Huge quantities of these compounds are imported into the UK and between May and August 2010, four shipments of Benzocaine amounting to more then 4 tons had been seized as part of Operation Kitley, a joint initiative between the UK Border Agency and the Serious Organised Crime Agency (SOCA). By diluting cocaine, traffickers can make it go a lot further for very little cost, leading to huge profits. In recent years, dealers have moved away from inert substances, like sugar and baby milk powder, in favour of active pharmaceutical ingredients (APIs), including anaesthetics like Benzocaine and Lidocaine. Both these mimic the numbing effect of cocaine, and resemble it closely in colour, texture and some chemical behaviours, making it easier to conceal the fact that the drug has been diluted. API cutting agents have helped traffickers to maintain steady supplies in the face of successful interdiction and even expand the market in the UK, particularly to young people aged from their mid teens to early twenties. From importation to street-level, the purity of the drug can be reduced up to a factor of 80 and street level cocaine can have a cocaine content as low as 1%. In view of the increasing use of Benzocaine as cutting agent for Cocaine, a study was carried out to investigate if 2H, 13C, 15N and 18O stable isotope signatures could be used in conjunction with multivariate chemometric data analysis to determine potential linkage between benzocaine exhibits seized from different locations or individuals to assist with investigation and prosecution of drug distribution network. More than 40 Benzocaine samples comprising both seized and control samples were analysed by two stable isotope forensic laboratories in two different countries (Australia and Scotland) to assess intra-lab reproducibility as well as inter-lab repeatability of measured stable isotope abundance values.

  1. The Practical Application of Aqueous Geochemistry in Mapping Groundwater Flow Systems in Fractured Rock Masses

    NASA Astrophysics Data System (ADS)

    Bursey, G.; Seok, E.; Gale, J. E.

    2017-12-01

    Flow to underground mines and open pits takes place through an interconnected network of regular joints/fractures and intermediate to large scale structural features such as faults and fracture zones. Large scale features can serve either as high permeability pathways or as barriers to flow, depending on the internal characteristics of the structure. Predicting long term water quality in barrier-well systems and long-term mine water inflows over a mine life, as a mine expands, requires the use of a 3D numerical flow and transport code. The code is used to integrate the physical geometry of the fractured-rock mass with porosity, permeability, hydraulic heads, storativity and recharge data and construct a model of the flow system. Once that model has been calibrated using hydraulic head and permeability/inflow data, aqueous geochemical and isotopic data provide useful tools for validating flow-system properties, when one is able to recognize and account for the non-ideal or imperfect aspects of the sampling methods used in different mining environments. If groundwater samples are collected from discrete depths within open boreholes, water in those boreholes have the opportunity to move up or down in response to the forces that drive groundwater flow, whether they be hydraulic gradients, gas pressures, or density differences associated with variations in salinity. The use of Br/Cl ratios, for example, can be used to determine if there is active flow into, or out of, the boreholes through open discontinuities in the rock mass (i.e., short-circuiting). Natural groundwater quality can also be affected to varying degrees by mixing with drilling fluids. The combined use of inorganic chemistry and stable isotopes can be used effectively to identify dilution signals and map the dilution patterns through a range of fresh, brackish and saline water types. The stable isotopes of oxygen and hydrogen are nearly ideal natural tracers of water, but situations occur when deep groundwater samples can plot to the left of the meteoric water line as a result of isotopic exchange between meteoric water and silicate rock in near-surface environments at low temperatures. These and other examples are considered in the practical application of aqueous geochemistry in helping to map flow systems in fractured-rock systems.

  2. Probing Reversible Chemistry in Coenzyme B12-Dependent Ethanolamine Ammonia Lyase with Kinetic Isotope Effects

    PubMed Central

    Jones, Alex R; Rentergent, Julius; Scrutton, Nigel S; Hay, Sam

    2015-01-01

    Coenzyme B12-dependent enzymes such as ethanolamine ammonia lyase have remarkable catalytic power and some unique properties that enable detailed analysis of the reaction chemistry and associated dynamics. By selectively deuterating the substrate (ethanolamine) and/or the β-carbon of the 5′-deoxyadenosyl moiety of the intrinsic coenzyme B12, it was possible to experimentally probe both the forward and reverse hydrogen atom transfers between the 5′-deoxyadenosyl radical and substrate during single-turnover stopped-flow measurements. These data are interpreted within the context of a kinetic model where the 5′-deoxyadenosyl radical intermediate may be quasi-stable and rearrangement of the substrate radical is essentially irreversible. Global fitting of these data allows estimation of the intrinsic rate constants associated with CoC homolysis and initial H-abstraction steps. In contrast to previous stopped-flow studies, the apparent kinetic isotope effects are found to be relatively small. PMID:25950663

  3. The mechanism of hydroaminoalkylation catalyzed by group 5 metal binaphtholate complexes.

    PubMed

    Reznichenko, Alexander L; Hultzsch, Kai C

    2012-02-15

    The intermolecular hydroaminoalkylation of unactivated alkenes and vinyl arenes with secondary amines occurs readily in the presence of tantalum and niobium binaphtholate catalysts with high regio- and enantioselectivity (up to 98% ee). Mechanistic studies have been conducted in order to determine the kinetic order of the reaction in all reagents and elucidate the rate- and stereodetermining steps. The effects of substrate steric and electronic properties on the overall reaction rate have been evaluated. The reaction is first order in amine and the catalyst, while exhibiting saturation in alkene at high alkene concentration. Unproductive reaction events including reversible amine binding and arene C-H activation have been observed. The formation of the metallaaziridine is a fast reversible nondissociative process and the overall reaction rate is limited either by amide exchange or alkene insertion, as supported by reaction kinetics, kinetic isotope effects, and isotopic labeling studies. These results suggest that the catalytic activity can be enhanced by employing a more electron-deficient ligand backbone.

  4. Effects of Lubrol detergents on adenylate cyclases.

    PubMed

    Bär, H P; Kulshrestha, S

    1975-04-01

    The nonionic detergent Lubrol WX showed diverse, concentration-dependent effects onbasal and stimulated adenylate cyclases. Above concentrations of 0.001-0.01% Lubrol WX, the basal activity of cyclase from Ehrlich ascites cells was inhibed about 50%, and that from rat fat cells was doubled. In both cases, hormonal sensitivity was lost at 0.01%. These effects were reversed upon dilution of the detergent. It is suggested that solubilization of adenylate cyclases at such low concentrations of Lubrol should be attempted since it is conceivable that loss of hormone sensitivity may then be reversible. Different Lubrol-type detergents may also offer centain advantages, since Lubrol PX effects were not identical with those of Lubrol WX.

  5. A model for osmium isotopic evolution of metallic solids at the core-mantle boundary

    NASA Astrophysics Data System (ADS)

    Humayun, Munir

    2011-03-01

    Some plumes are thought to originate at the core-mantle boundary, but geochemical evidence of core-mantle interaction is limited to Os isotopes in samples from Hawaii, Gorgona (89 Ma), and Kostomuksha (2.7 Ga). The Os isotopes have been explained by physical entrainment of Earth's liquid outer core into mantle plumes. This model has come into conflict with geophysical estimates of the timing of core formation, high-pressure experimental determinations of the solid metal-liquid metal partition coefficients (D), and the absence of expected 182W anomalies. A new model is proposed where metallic liquid from the outer core is partially trapped in a compacting cumulate pile of Fe-rich nonmetallic precipitates (FeO, FeS, Fe3Si, etc.) at the top of the core and undergoes fractional crystallization precipitating solid metal grains, followed by expulsion of the residual metallic liquid back to the outer core. The Os isotopic composition of the solids and liquids in the cumulate pile is modeled as a function of the residual liquid remaining and the emplacement age using 1 bar D values, with variable amounts of oxygen (0-10 wt %) as the light element. The precipitated solids evolve Os isotope compositions that match the trends for Hawaii (at an emplacement age of 3.5-4.5 Ga; 5%-10% oxygen) and Gorgona (emplacement age < 1.5 Ga; 0%-5% oxygen). The Fe-rich matrix of the cumulate pile dilutes the precipitated solid metal decoupling the Fe/Mn ratio from Os and W isotopes. The advantages to using precipitated solid metal as the Os host include a lower platinum group element and Ni content to the mantle source region relative to excess iron, miniscule anomalies in 182W (<0.1 ɛ), and no effects for Pb isotopes, etc. A gradual thermomechanical erosion of the cumulate pile results in incorporation of this material into the base of the mantle, where mantle plumes subsequently entrain it. Fractional crystallization of metallic liquids within the CMB provides a consistent explanation of both Os isotope correlations, Os-W isotope systematics, and Fe/Mn evidence for core-mantle interaction over the entire Hawaiian source.

  6. Uranium isotopes in groundwater occurring at Amazonas State, Brazil.

    PubMed

    da Silva, Márcio Luiz; Bonotto, Daniel Marcos

    2015-03-01

    This paper reports the behavior of the dissolved U-isotopes (238)U and (234)U in groundwater providing from 15 cities in Amazonas State, Brazil. The isotope dilution technique accompanied by alpha spectrometry were utilized for acquiring the U content and (234)U/(238)U activity ratio (AR) data, 0.01-1.4µgL(-1) and 1.0-3.5, respectively. These results suggest that the water is circulating in a reducing environment and leaching strata containing minerals with low uranium concentration. A tendency to increasing ARs values following the groundwater flow direction is identified in Manaus city. The AR also increases according to the SW-NE directions: Uarini→Tefé; Manacapuru→Manaus; Presidente Figueiredo→São Sebastião do Uatumã; and Boa Vista do Ramos→Parintins. Such trends are possibly related to several factors, among them the increasing acid character of the waters. The waters analyzed are used for human consumption and the highest dissolved U content is much lower than the maximum established by the World Health Organization. Therefore, in view of this radiological parameter they can be used for drinking purposes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. A novel paper-based assay for the simultaneous determination of Rh typing and forward and reverse ABO blood groups.

    PubMed

    Noiphung, Julaluk; Talalak, Kwanrutai; Hongwarittorrn, Irin; Pupinyo, Naricha; Thirabowonkitphithan, Pannawich; Laiwattanapaisal, Wanida

    2015-05-15

    We propose a new, paper-based analytical device (PAD) for blood typing that allows for the simultaneous determination of ABO and Rh blood groups on the same device. The device was successfully fabricated by using a combination of wax printing and wax dipping methods. A 1:2 blood dilution was used for forward grouping, whereas whole blood could be used for reverse grouping. A 30% cell suspension of A-cells or B-cells was used for haemagglutination on the reverse grouping side. The total assay time was 10 min. The ratio between the distance of red blood cell movement and plasma separation is the criterion for agglutination and indicates the presence of the corresponding antigen or antibody. The proposed PAD has excellent reproducibility in that the same blood groups, namely A, AB, and O, were reported by using different PADs that were fabricated on the same day (n=10). The accuracy for detecting blood group A (n=12), B (n=13), AB (n=9), O (n=14), and Rh (n=48) typing were 92%, 85%, 89%, 93%, and 96%, respectively, in comparison with the conventional slide test method. The haematocrit of the sample affects the accuracy of the results, and appropriate dilution is suggested before typing. In conclusion, this study proposes a novel method that is straightforward, time-saving, and inexpensive for the simultaneous determination of ABO and Rh blood groups, which is promising for use in developing countries. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Reversal of spontaneous magnetization and spontaneous exchange bias for Sm1-xYxCrO3: The effect of Y doping

    NASA Astrophysics Data System (ADS)

    Zhang, Hongguang; Wang, Jianhua; Xie, Liang; Fu, Dexiang; Guo, Yanyan; Li, Yongtao

    2017-11-01

    We report the crystal and electronic structures and magnetic properties of non-magnetic Y3+ ion doped SmCrO3 crystals. Structural distortion and electronic structure variation are caused by cation disorder due to Y doping. Although the spin moment of Sm3+ is diluted by nonmagnetic Y ions, spin reorientation continues to exist, and the temperature-dependent magnetization reversal effect and the spontaneous exchange bias effect under zero field cooling are simultaneously induced below Neel temperature. Significantly, the method of doping promotes the achievement of temperature dependent tunable switching of magnetization and sign of a spontaneous exchange bias from positive to negative. Our work provides more tunable ways to the sign reversal of magnetization and exchange bias, which have potential application in designing magnetic random access memory devices, thermomagnetic switches and spin-valve devices.

  9. Speciation and isotopic exchangeability of nickel in soil solution.

    PubMed

    Nolan, Annette L; Ma, Yibing; Lombi, Enzo; McLaughlin, Mike J

    2009-01-01

    Knowledge of trace metal speciation in soil pore waters is important in addressing metal bioavailability and risk assessment of contaminated soils. In this study, free Ni(2+) activities were determined in pore waters of long-term Ni-contaminated soils using a Donnan dialysis membrane technique. The pore water free Ni(2+) concentration as a percentage of total soluble Ni ranged from 21 to 80% (average 53%), and the average amount of Ni bound to dissolved organic matter estimated by Windermere Humic Aqueous Model VI was < or = 17%. These data indicate that complexed forms of Ni can constitute a significant fraction of total Ni in solution. Windermere Humic Aqueous Model VI provided reasonable estimates of free Ni(2+) fractions in comparison to the measured fractions (R(2) = 0.83 with a slope of 1.0). Also, the isotopically exchangeable pools (E value) of soil Ni were measured by an isotope dilution technique using water extraction, with and without resin purification, and 0.1 mol L(-1) CaCl(2) extraction, and the isotopic exchangeability of Ni species in soil water extracts was investigated. The concentrations of isotopically non-exchangeable Ni in water extracts were <9% of total water soluble Ni concentrations for all soils. The resin E values expressed as a percentage of the total Ni concentrations in soil showed that the labile Ni pool ranged from 0.9 to 32.4% (average 12.4%) of total soil Ni. Therefore the labile Ni pool in these well-equilibrated contaminated soils appears to be relatively small in relation to total Ni concentrations.

  10. Inductively coupled plasma mass spectrometry for stable isotope metabolic tracer studies of living systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luong, Elise

    1999-05-10

    This dissertation focuses on the development of methods for stable isotope metabolic tracer studies in living systems using inductively coupled plasma single and dual quadrupole mass spectrometers. Sub-nanogram per gram levels of molybdenum (Mo) from human blood plasma are isolated by the use of anion exchange alumina microcolumns. Million-fold more concentrated spectral and matrix interferences such as sodium, chloride, sulfate, phosphate, etc. in the blood constituents are removed from the analyte. The recovery of Mo from the alumina column is 82 ± 5% (n = 5). Isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is utilized for the quantitative ultra-tracemore » concentration determination of Mo in bovine and human blood samples. The average Mo concentration in reference bovine serum determined by this method is 10.2 ± 0.4 ng/g, while the certified value is 11.5 ± 1.1 ng/g (95% confidence interval). The Mo concentration of one pool of human blood plasma from two healthy male donors is 0.5 ± 0.1 ng/g. The inductively coupled plasma twin quadrupole mass spectrometer (ICP-TQMS) is used to measure the carbon isotope ratio from non-volatile organic compounds and bio-organic molecules to assess the ability as an alternative analytical method to gas chromatography combustion isotope ratio mass spectrometry (GC-combustion-IRMS). Trytophan, myoglobin, and β-cyclodextrin are chosen for the study, initial observation of spectral interference of 13C + with 12C 1H + comes from the incomplete dissociation of myoglobin and/or β-cyclodextrin.« less

  11. Quantitation of 5-Methyltetrahydrofolate in Cerebrospinal Fluid Using Liquid Chromatography-Electrospray Tandem Mass Spectrometry.

    PubMed

    Arning, Erland; Bottiglieri, Teodoro

    2016-01-01

    We describe a simple stable isotope dilution method for accurate and precise measurement of cerebrospinal fluid (CSF) 5-methyltetrahydrofolate (5-MTHF) as a clinical diagnostic test. 5-MTHF is the main biologically active form of folic acid and is involved in regulation of homocysteine and DNA synthesis. Measurement of 5-MTHF in CSF provides diagnostic information regarding diseases affecting folate metabolism within the central nervous system, in particular inborn errors of folate metabolism. Determination of 5-MTHF in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). 5-MTHF in CSF is determined by a 1:2 dilution with internal standard (5-MTHF-(13)C5) and injected directly onto the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve (25-400 nM) and has an analytical measurement range of 3-1000 nM.

  12. Nuclear applications of inorganic mass spectrometry.

    PubMed

    De Laeter, John

    2010-01-01

    There are several basic characteristics of mass spectrometry that are not always fully appreciated by the science community. These characteristics include the distinction between relative and absolute isotope abundances, and the influence of isotope fractionation on the accuracy of isotopic measurements. These characteristics can be illustrated in the field of nuclear physics with reference to the measurement of nuclear parameters, which involve the use of enriched isotopes, and to test models of s-, r-, and p-process nucleosynthesis. The power of isotope-dilution mass spectrometry (IDMS) to measure trace elements in primitive meteorites to produce accurate Solar System abundances has been essential to the development of nuclear astrophysics. The variety of mass spectrometric instrumentation used to measure the isotopic composition of elements has sometimes been accompanied by a lack of implementation of basic mass spectrometric protocols which are applicable to all instruments. These metrological protocols are especially important in atomic weight determinations, but must also be carefully observed in cases where the anomalies might be very small, such as in studies of the daughter products of extinct radionuclides to decipher events in the early history of the Solar System. There are occasions in which misleading conclusions have been drawn from isotopic data derived from mass spectrometers where such protocols have been ignored. It is important to choose the mass spectrometer instrument most appropriate to the proposed experiment. The importance of the integrative nature of mass spectrometric measurements has been demonstrated by experiments in which long, double beta decay and geochronological decay half-lives have been measured as an alternative to costly radioactive-counting experiments. This characteristic is also illustrated in the measurement of spontaneous fission yields, which have accumulated over long periods of time. Mass spectrometry is also a valuable tool in the determination of neutron capture cross-section measurements and the application of such determinations in Planetary Science. 2009 Wiley Periodicals, Inc.

  13. Mineral associations and character of isotopically anomalous organic material in the Tagish Lake carbonaceous chondrite

    NASA Astrophysics Data System (ADS)

    Zega, Thomas J.; Alexander, Conel M. O.'D.; Busemann, Henner; Nittler, Larry R.; Hoppe, Peter; Stroud, Rhonda M.; Young, Andrea F.

    2010-10-01

    We report a coordinated analytical study of matrix material in the Tagish Lake carbonaceous chondrite in which the same small (⩽20 μm) fragments were measured by secondary ion mass spectrometry (SIMS), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDS), electron energy-loss spectroscopy (EELS), and X-ray absorption near-edge spectroscopy (XANES). SIMS analysis reveals H and N isotopic anomalies (hotspots), ranging from hundreds to thousands of nanometers in size, which are present throughout the fragments. Although the differences in spatial resolution of the SIMS techniques we have used introduce some uncertainty into the exact location of the hotspots, in general, the H and N isotopic anomalies are spatially correlated with C enrichments, suggesting an organic carrier. TEM analysis, enabled by site-specific extraction using a focused-ion-beam scanning-electron microscope, shows that the hotspots contain an amorphous component, Fe-Ni sulfides, serpentine, and mixed-cation carbonates. TEM imaging reveals that the amorphous component occurs in solid and porous forms, EDS indicates that it contains abundant C, and EELS and XANES at the C K edge reveal that it is largely aromatic. This amorphous component is probably macromolecular C, likely the carrier of the isotopic anomalies, and similar to the material extracted from bulk samples as insoluble organic matter. However, given the large sizes of some of the hotspots, the disparity in spatial resolution among the various techniques employed in our study, and the phases with which they are associated, we cannot entirely rule out that some of the isotopic anomalies are carried by inorganic material, e.g., sheet silicates. The isotopic composition of the organic matter points to an initially primitive origin, quite possibly within cold interstellar clouds or the outer reaches of the solar protoplanetary disk. The association of organic material with secondary phases, e.g., serpentine and carbonates, suggests that the organic matter was susceptible to parent-body processing, and thus, isotopic dilution.

  14. The effects of isotope-labeled analogs on the LC-IDMS measurement by comparison of ESI responses and matrix effect of melamine, 13C3-melamine, 13C3+15N3-melamine, and 15N3-melamine.

    PubMed

    Li, Xiu Qin; Zhang, Qing He; Yang, Zong; Li, Hong Mei; Huang, Dong Feng

    2017-05-01

    In this paper, the effect of isotope-labeled analogs on the liquid chromatography-isotope dilution mass spectrometry (LC-IDMS) measurement was evaluated based on the comparison research of electrospray ionization responses (ESI) and matrix effect of melamine, 13 C 3 -melamine, 13 C 3 + 15 N 3 -melamine, and 15 N 3 -melamine. The isotope-labeled melamines had similar ionization efficiency with melamine in the electrospray ionization source, but the intensity of corresponding quantitative fragment ions had distinctive differences. Based on the density functional theory at the B3LYP/6-311+G** level, this phenomenon was explained very well. The rare cleavage pathways of melamine, which just could be exactly identified by 15 N-labeled melamines, resulted in the difference of quantitative fragment ions between 15 N-labeled melamines and melamine. The interaction of ESI response between melamine and isotope-labeled melamines was investigated using MRM monitor mode. 15 N-labeled melamine had significant ion inter-suppression effect on melamine, while 13 C-labeled melamine had little influence on melamine. Finally, the influence of different isotope-labeled melamines on the LC-IDMS result was evaluated using the IDMS correction factor (θ). Taking the determination of melamine in milk powder as an example, the matrix effects of different isotope-labeled melamines and melamine had notable difference and the impact of this difference on the measurement results depended on the concentrations of analyte and matrix solution. It was worth noting that 15 N 3 -melamine exhibited significant ion suppression to melamine in matrix solution. The deviation of the results from IDMS method might reach 59% using 15 N 3 -melamine as internal standard in special matrix solution. Graphical Abstract The comparison of ESI responses of melamine, 13 C 3 -melamine, 13 C 3 + 15 N 3 -melamine and 15 N 3 -melamine.

  15. A review of lunar chronology revealing a preponderance of 4.34-4.37 Ga ages

    DOE PAGES

    Borg, Lars E.; Gaffney, Amy M.; Shearer, Charles K.

    2014-11-24

    In this study, data obtained from Sm-Nd and Rb-Sr isotopic measurements of lunar highlands’ samples are renormalized to common standard values and then used to define ages with a common isochron regression algorithm. The reliability of these ages is evaluated using five criteria that include whether: (1) the ages are defined by multiple isotopic systems, (2) the data demonstrate limited scatter outside uncertainty, (3) initial isotopic compositions are consistent with the petrogenesis of the samples, (4) the ages are defined by an isotopic system that is resistant to disturbance by impact metamorphism, and (5) the rare-earth element abundances determined bymore » isotope dilution of bulk of mineral fractions match those measured by in situ analyses. From this analysis, it is apparent that the oldest highlands’ rock ages are some of the least reliable, and that there is little support for crustal ages older than ~4.40 Ga. A model age for ur-KREEP formation calculated using the most reliable Mg-suite Sm-Nd isotopic systematics, in conjunction with Sm-Nd analyses of KREEP basalts, is 4389 ± 45 Ma. This age is a good match to the Lu-Hf model age of 4353 ± 37 Ma determined using a subset of this sample suite, the average model age of 4353 ± 25 Ma determined on mare basalts with the 146Sm- 142Nd isotopic system, with a peak in Pb-Pb ages observed in lunar zircons of ~4340 ± 20 Ma, and the oldest terrestrial zircon age of 4374 ± 6 Ma. The preponderance of ages between 4.34 and 4.37 Ga reflect either primordial solidification of a lunar magma ocean or a widespread secondary magmatic event on the lunar nearside. The first scenario is not consistent with the oldest ages reported for lunar zircons, whereas the second scenario does not account for concordance between ages of crustal rocks and mantle reservoirs.« less

  16. 40Ar/39Ar Dating of the Brunhes-Matuyama Geomagnetic Field Reversal.

    PubMed

    Baksi, A K; Hsu, V; McWilliams, M O; Farrar, E

    1992-04-17

    Magnetostratigraphic studies are widely used in conjunction with the geomagnetic polarity time scale (GPTS) to date events in the range 0 to 5 million years ago. A critical tie point on the GPTS is the potassium-argon age of the most recent (Brunhes-Matuyama) geomagnetic field reversal. Astronomical values for the forcing frequencies observed in the oxygen isotope record in Ocean Drilling Project site 677 suggest that the age of this last reversal is 780 ka (thousand years ago), whereas the potassium-argon-based estimate is 730 ka. Results from 4039; Ar incremental heating studies on a series of lavas from Maui that straddle the Brunhes-Matuyama reversal give an age of 783 + 11 ka, in agreement with the astronomically derived value. The astronomically based technique appears to be a viable tool for dating young sedimentary sequences.

  17. Sr and Nd isotopes of suspended sediments from rivers of the Amazon basin

    NASA Astrophysics Data System (ADS)

    Hatting, Karina; Santos, Roberto V.; Sondag, Francis

    2014-05-01

    The Rb-Sr and Sm-Nd isotopic systems are important tools to constrain the provenance of sediment load in river systems. This study presents the isotopic composition of Sr and Nd isotopes and major and minor elements in suspended sediments from the Marañón-Solimões, Amazonas and Beni-Madeira rivers. The data were used to constrain the source region of the sediments and to better understand the main seasonal and spatial transport processes within the basin based on the variations of the chemical and isotopic signals. They also allow establishing a relationship between sediment concentrations and flow rate values. The study presents data collected during a hydrological year between 2009 and 2010. The Marañón-Solimões River presents low Sr isotopic values (0.7090-0.7186), broad EpslonNd(0) range (-15.17 to -8.09) and Nd model (TDM) ages varying from 0.99 to 1.81 Ga. Sources of sediments to the Marañón-Solimões River include recent volcanic rocks in northern Peru and Ecuador, as well as rocks with long crustal residence time and carbonates from the Marañón Basin, Peru. The Beni-Madeira River has more radiogenic Sr isotope values (0.7255-0.7403), more negative EpslonNd(0) values (-20.46 to -10.47), and older Nd isotope model ages (from 1.40 to 2.35 Ga) when compared to the Marañón-Solimões River. These isotope data were related to the erosion of Paleozoic and Cenozoic foreland basins that are filled with Precambrian sediments derived from the Amazonian Craton. These basins are located in Bolivian Subandina Zone. The Amazon River presents intermediate isotopic values when compared to those found in the Marañón-Solimões and Beni-Madeira rivers. Its Sr isotope ratios range between 0.7193 and 0.7290, and its EpslonNd(0) values varies between -11.09 and -9.51. The Nd isotope model ages of the suspended sediments vary between 1.28 and 1.77 Ga. Concentrations of soluble and insoluble elements indicate a more intense weathering activity in sediments of the Beni-Madeira River. This river has a larger difference in the Sr isotopic composition between the diluted and solid phases, which has been assigned to the high level of weathering of its sediment source area. In the Beni-Madeira River sub-basin dominates weathering of silicate rocks, while in the Marañón-Solimões River sub-basin there also weathering of carbonate and evaporitic rocks.

  18. Mean-field studies of time reversal breaking states in super-heavy nuclei with the Gogny force

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robledo, L. M., E-mail: luis.robledo@uam.es

    2015-10-15

    Recent progress on the description of time reversal breaking (odd mass and multi-quasiparticle excitation) states in super-heavy nuclei within a mean field framework and using several flavors of the Gogny interaction is reported. The study includes ground and excited states in selected odd mass isotopes of nobelium and mendelevium as well as high K isomeric states in {sup 254}No. These are two and four-quasiparticle excitations that are treated in the same self-consistent HFB plus blocking framework as the odd mass states.

  19. F-T Jet Fuel Reverse Mutation Assay and Chromosome Aberration Test

    DTIC Science & Technology

    2010-11-01

    Assay The test item was dissolved in ethanol and diluted prior to treatment. The solvent was compatible with the survival of the bacteria and the S9...demonstrated the effective performance of the test. Negative solvent controls, consisting of solvent or vehicle alone as well as untreated controls...without Metabolic Activation S. typhimurium Strain Control Supplier Purity Solvent Concentration Without metabolic activation TA 100, TA 1535

  20. High field hyperpolarization-EXSY experiment for fast determination of dissociation rates in SABRE complexes

    NASA Astrophysics Data System (ADS)

    Hermkens, Niels K. J.; Feiters, Martin C.; Rutjes, Floris P. J. T.; Wijmenga, Sybren S.; Tessari, Marco

    2017-03-01

    SABRE (Signal Amplification By Reversible Exchange) is a nuclear spin hyperpolarization technique based on the reversible concurrent binding of small molecules and para-hydrogen (p-H2) to an iridium metal complex in solution. At low magnetic field, spontaneous conversion of p-H2 spin order to enhanced longitudinal magnetization of the nuclear spins of the other ligands occurs. Subsequent complex dissociation results in hyperpolarized substrate molecules in solution. The lifetime of this complex plays a crucial role in attained SABRE NMR signal enhancements. Depending on the ligands, vastly different dissociation rates have been previously measured using EXSY or selective inversion experiments. However, both these approaches are generally time-consuming due to the long recycle delays (up to 2 min) necessary to reach thermal equilibrium for the nuclear spins of interest. In the cases of dilute solutions, signal averaging aggravates the problem, further extending the experimental time. Here, a new approach is proposed based on coherent hyperpolarization transfer to substrate protons in asymmetric complexes at high magnetic field. We have previously shown that such asymmetric complexes are important for application of SABRE to dilute substrates. Our results demonstrate that a series of high sensitivity EXSY spectra can be collected in a short experimental time thanks to the NMR signal enhancement and much shorter recycle delay.

  1. Phosphatidylcholine embedded micellar systems: enhanced permeability through rat skin.

    PubMed

    Spernath, Aviram; Aserin, Abraham; Sintov, Amnon C; Garti, Nissim

    2008-02-15

    Micellar and microemulsion systems are excellent potential vehicles for delivery of drugs because of their high solubilization capacity and improved transmembrane bioavailability. Mixtures of propylene glycol (PG) and nonionic surfactants with sodium diclofenac (DFC) were prepared in the presence of phosphatidylcholine (PC) as transmembrane transport enhancers. Fully dilutable systems with maximum DFC solubilization capacity (SC) at pH 7 are presented. It was demonstrated that the concentrates underwent phase transitions from reverse micelles to swollen reverse micelles and, via the bicontinuous transitional mesophase, into inverted O/W microstructures. The SC decreases as a function of dilution. DFC transdermal penetration using rat skin in vitro correlated with SC, water content, effect of phospholipid content, presence of an oil phase, and ethanol. Skin penetration from the inverted bicontinuous mesophase and the skin penetration from the O/W-like microstructure were higher than that measured from the W/O-like droplets, especially when the micellar system containing the nonionic surfactant, sugar ester L-1695, and hexaglycerol laurate. PC embedded within the micelle interface significantly increased the penetration flux across the skin compared to micellar systems without the embedded PC at their interface. Moreover, the combination of PC with HECO40 improved the permeation rate (P) and shortened the lag-time (T(L)).

  2. Oxygen isotope analysis of phosphate: improved precision using TC/EA CF-IRMS.

    PubMed

    LaPorte, D F; Holmden, C; Patterson, W P; Prokopiuk, T; Eglington, B M

    2009-06-01

    Oxygen isotope values of biogenic apatite have long demonstrated considerable promise for paleothermometry potential because of the abundance of material in the fossil record and greater resistance of apatite to diagenesis compared to carbonate. Unfortunately, this promise has not been fully realized because of relatively poor precision of isotopic measurements, and exceedingly small size of some substrates for analysis. Building on previous work, we demonstrate that it is possible to improve precision of delta18O(PO4) measurements using a 'reverse-plumbed' thermal conversion elemental analyzer (TC/EA) coupled to a continuous flow isotope ratio mass spectrometer (CF-IRMS) via a helium stream [Correction made here after initial online publication]. This modification to the flow of helium through the TC/EA, and careful location of the packing of glassy carbon fragments relative to the hot spot in the reactor, leads to narrower, more symmetrically distributed CO elution peaks with diminished tailing. In addition, we describe our apatite purification chemistry that uses nitric acid and cation exchange resin. Purification chemistry is optimized for processing small samples, minimizing isotopic fractionation of PO4(-3) and permitting Ca, Sr and Nd to be eluted and purified further for the measurement of delta44Ca and 87Sr/86Sr in modern biogenic apatite and 143Nd/144Nd in fossil apatite. Our methodology yields an external precision of +/- 0.15 per thousand (1sigma) for delta18O(PO4). The uncertainty is related to the preparation of the Ag3PO4 salt, conversion to CO gas in a reversed-plumbed TC/EA, analysis of oxygen isotopes using a CF-IRMS, and uncertainty in constructing calibration lines that convert raw delta18O data to the VSMOW scale. Matrix matching of samples and standards for the purpose of calibration to the VSMOW scale was determined to be unnecessary. Our method requires only slightly modified equipment that is widely available. This fact, and the demonstrated improvement in precision, should help to make apatite paleothermometry far more accessible to paleoclimate researchers. Copyright 2009 John Wiley & Sons, Ltd.

  3. Oxidoreductive capability of boar sperm mitochondria in fresh semen and during their preservation in BTS extender.

    PubMed

    Gaczarzewicz, Dariusz; Piasecka, Małgorzata; Udała, Jan; Błaszczyk, Barbara; Laszczyńska, Maria; Kram, Andrzej

    2003-07-01

    The purpose of our study was to determine the effect of dilution and liquid-preservation of boar sperm on oxidoreductive capability of their mitochondria. The semen was diluted with BTS extender produced from water purified by destillation or by reverse osmosis. The spermatozoa were stored over a four-day period at 16-18 degrees C. The function of sperm mitochondria was assessed using the screening cytochemical test for NADH-dependent oxidoreductases (diaphorase/NADH, related to flavoprotein). Morphological assessment of cytochemical reaction was carried out using a light microscope. The intensity of the reaction was evaluated by means of a computer image analysing system (Quantimet 600S), measuring the integrated optical density (IOD) and mean optical density (MOD) of the reaction product (formazans) occurring in the sperm midpieces. In the non-diluted semen, intensive cytochemical reaction throughout the length of the sperm midpiece was observed. Furthermore, spermatozoa with the intensive reaction displayed the high optical density values. After dilution the semen with two variants of experimental extender, and as the conservation time expired, the cytochemical reaction was less intensive. Moreover, the absence of formazan deposits in various parts of the sperm midpiece was also noted. These morphological features corresponded to low values of optical density. These findings suggest that the dilution of semen and the time of sperm preservation may be critical factors that handicap energy metabolism of sperm mitochondria. The type of water used in preparing BTS extender does not have any significant effect on the oxidoreductive capability of sperm boar mitochondria.

  4. Improved Quaternary North Atlantic stratigraphy using relative paleointensity (RPI), oxygen isotopes, and magnetic excursions (Invited)

    NASA Astrophysics Data System (ADS)

    Channell, J. E.

    2013-12-01

    Improving the resolution of Quaternary marine stratigraphy is one of the major challenges in paleoceanography. IODP Expedition 303/306, and ODP Legs 162 and 172, have yielded multiple high-resolution records (mean sedimentation rates in the 7-20 cm/kyr range) of relative paleointensity (RPI) that are accompanied by oxygen isotope data and extend through much of the Quaternary. Tandem fit of RPI and oxygen isotope data to calibrated templates (LR04 and PISO), using the Match protocol, yields largely consistent stratigraphies, implying that both RPI and oxygen isotope data are dominated by regional/global signals. Based on the recent geomagnetic field, RPI can be expected to be a global signal (i.e. dominated by the axial dipole field) when recorded at sedimentation rates less than several decimeters/kyr. Magnetic susceptibility, on the other hand, is a local/regional lithologic signal, and therefore less useful for long-distance correlation. Magnetic excursions are directional phenomena and, when adequately recorded, are manifest as paired reversals in which the virtual geomagnetic poles (VGPs) reach high latitudes in the opposite hemisphere, and they occupy minima in RPI records. Reversed VGPs imply that excursions are attributable to the main axial dipole, and therefore provide global stratigraphy. The so-called Iceland Basin excursion is recorded at many IODP/ODP sites and lies at the MIS 6/7 boundary at ~188 ka, with a duration of 2-3 kyr. Other excursions in the Brunhes chron are less commonly recorded because their duration (perhaps <~1 kyr) requires sedimentation rates >20 cm/kyr to be adequately recorded. On the other hand, several excursions within the Matuyama Chron are more commonly recorded in North Atlantic drift sediments due to relatively elevated durations. With some notable exceptions (e.g. Iberian Margin), high quality RPI records from North Atlantic sediments, together with magnetic excursions, can be used in tandem with oxygen isotope data to strengthen Quaternary (North Atlantic) stratigraphy.

  5. Accurate analysis of parabens in human urine using isotope-dilution ultrahigh-performance liquid chromatography-high resolution mass spectrometry.

    PubMed

    Zhou, Hui-Ting; Chen, Hsin-Chang; Ding, Wang-Hsien

    2018-02-20

    An analytical method that utilizes isotope-dilution ultrahigh-performance liquid chromatography coupled with hybrid quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS or called UHPLC-HRMS) was developed, and validated to be highly precise and accurate for the detection of nine parabens (methyl-, ethyl-, propyl-, isopropyl-, butyl-, isobutyl-, pentyl-, hexyl-, and benzyl-parabens) in human urine samples. After sample preparation by ultrasound-assisted emulsification microextraction (USAEME), the extract was directly injected into UHPLC-HRMS. By using negative electrospray ionization in the multiple reaction monitoring (MRM) mode and measuring the peak area ratios of both the natural and the labeled-analogues in the samples and calibration standards, the target analytes could be accurately identified and quantified. Another use for the labeled-analogues was to correct for systematic errors associated with the analysis, such as the matrix effect and other variations. The limits of quantitation (LOQs) were ranging from 0.3 to 0.6 ng/mL. High precisions for both repeatability and reproducibility were obtained ranging from 1 to 8%. High trueness (mean extraction recovery, or called accuracy) ranged from 93 to 107% on two concentration levels. According to preliminary results, the total concentrations of four most detected parabens (methyl-, ethyl-, propyl- and butyl-) ranged from 0.5 to 79.1 ng/mL in male urine samples, and from 17 to 237 ng/mL in female urine samples. Interestingly, two infrequently detected pentyl- and hexyl-parabens were found in one of the male samples in this study. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Quantification of 16 polycyclic aromatic hydrocarbons in cigarette smoke condensate using stable isotope dilution liquid chromatography with atmospheric-pressure photoionization tandem mass spectrometry.

    PubMed

    Zhang, Xiaotao; Hou, Hongwei; Chen, Huan; Liu, Yong; Wang, An; Hu, Qingyuan

    2015-09-17

    A stable isotope dilution liquid chromatography with tandem mass spectrometry method for the analysis of 16 polycyclic aromatic hydrocarbons in cigarette smoke condensate was developed and validated. Compared with previously reported methods, this method has lower limits of detection (0.04-1.35 ng/cig). Additionally, the proposed method saves time, reduces the number of separation steps, and reduces the quantity of solvent needed. The new method was applied to evaluate polycyclic aromatic hydrocarbon content in 213 commercially available cigarettes in China, under the International Standardization Organization smoking regime and the Health Canadian intense smoking regime. The results showed that the total polycyclic aromatic hydrocarbon content was more than two times higher in samples from the Health Canadian intense smoking regime than in samples from the International Standardization Organization smoking regime (1189.23 vs. 2859.50 ng/cig, p<0.05). Meanwhile, the concentration of individual polycyclic aromatic hydrocarbons (and total polycyclic aromatic hydrocarbons) increased with labeled tar content in both of the tested smoking regimes. There was a positive correlation between total polycyclic aromatic hydrocarbons under the International Standardization Organization smoking regime with that under the Health Canadian intense smoking regime. The proposed liquid chromatography with tandem mass spectrometry method is satisfactory for the rapid, sensitive, and accurately quantitative evaluation of polycyclic aromatic hydrocarbon content in cigarette smoke condensate, and it can be applied to assess potential health risks from smoking. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  7. Parkinson-dementia complex and development of a new stable isotope dilution assay for BMAA detection in tissue

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Snyder, Laura R.; Cruz-Aguado, Reyniel; Sadilek, Martin

    2009-10-15

    {beta}-Methylamino-L-alanine (BMAA) has been proposed as a global contributor to neurodegenerative diseases, including Parkinson-dementia complex (PDC) of Guam and Alzheimer's disease (AD). The literature on the effects of BMAA is conflicting with some but not all in vitro data supporting a neurotoxic action, and experimental animal data failing to replicate the pattern of neurodegeneration of these human diseases, even at very high exposures. Recently, BMAA has been reported in human brain from individuals afflicted with PDC or AD. Some of the BMAA in human tissue reportedly is freely extractable (free) while some is protein-associated and liberated by techniques that hydrolyzemore » the peptide bond. The latter is especially intriguing since BMAA is a non-proteinogenic amino acid that has no known tRNA. We attempted to replicate these findings with techniques similar to those used by others; despite more than adequate sensitivity, we were unable to detect free BMAA. Recently, using a novel stable isotope dilution assay, we again were unable to detect free or protein-associated BMAA in human cerebrum. Here we review the development of our new assay for tissue detection of BMAA and show that we are able to detect free BMAA in liver but not cerebrum, nor do we detect any protein-associated BMAA in mice fed this amino acid. These studies demonstrate the importance of a sensitive and specific assay for tissue BMAA and seriously challenge the proposal that BMAA is accumulating in human brain.« less

  8. Neuronal metabolomics by ion mobility mass spectrometry: cocaine effects on glucose and selected biogenic amine metabolites in the frontal cortex, striatum, and thalamus of the rat.

    PubMed

    Kaplan, Kimberly A; Chiu, Veronica M; Lukus, Peter A; Zhang, Xing; Siems, William F; Schenk, James O; Hill, Herbert H

    2013-02-01

    We report results of studies of global and targeted neuronal metabolomes by ambient pressure ion mobility mass spectrometry. The rat frontal cortex, striatum, and thalamus were sampled from control nontreated rats and those treated with acute cocaine or pargyline. Quantitative evaluations were made by standard additions or isotopic dilution. The mass detection limit was ~100 pmol varying with the analyte. Targeted metabolites of dopamine, serotonin, and glucose followed the rank order of distribution expected between the anatomical areas. Data was evaluated by principal component analysis on 764 common metabolites (identified by m/z and reduced mobility). Differences between anatomical areas and treatment groups were observed for 53 % of these metabolites using principal component analysis. Global and targeted metabolic differences were observed between the three anatomical areas with contralateral differences between some areas. Following drug treatments, global and targeted metabolomes were found to shift relative to controls and still maintained anatomical differences. Pargyline reduced 3,4-dihydroxyphenylacetic acid below detection limits, and 5-HIAA varied between anatomical regions. Notable findings were: (1) global metabolomes were different between anatomical areas and were altered by acute cocaine providing a broad but targeted window of discovery for metabolic changes produced by drugs of abuse; (2) quantitative analysis was demonstrated using isotope dilution and standard addition; (3) cocaine changed glucose and biogenic amine metabolism in the anatomical areas tested; and (4) the largest effect of cocaine was on the glycolysis metabolome in the thalamus confirming inferences from previous positron emission tomography studies using 2-deoxyglucose.

  9. Isotope-dilution gas chromatography-mass spectrometry coupled with injection-port butylation for the determination of 4-t-octylphenol, 4-nonylphenols and bisphenol A in human urine.

    PubMed

    Chung, Shuang-Hung; Ding, Wang-Hsien

    2018-02-05

    An analytical method that utilizes isotope-dilution gas chromatography-mass spectrometry (ID-GC-MS) coupled with injection-port butylation was developed. The method was validated, and confirmed to be able to determine the presence of three commonly detected endocrine-disrupting chemicals (EDCs: 4-tert-octylphenol (4-t-OP), 4-nonylphenols (4-NPs) and bisphenol A (BPA)) in human urine with high precision and accuracy. After sample preparation by solid-phase extraction, the extract was introduced into GC-MS via injection-port butylation. The butylated target analytes were identified and quantified by using ion-trap mass spectrometry operating in the selected-ion-storage mode, and employing the measurement of peak area ratios of the butylated target analytes and labeled-analogues in the samples and calibration standards. The labeled-analogues were also used to correct the variations associated with the analysis and matrix effect. The limits of quantitation (LOQs) ranged from 0.1 to 0.3ng/mL. High precisions for both intra- and inter-day analysis ranged from 1 to 6%, and excellent accuracy (mean recovery) ranged from 92 to 105% on two concentration levels. In human urine, the total concentrations of three selected EDCs varied from 1.28 to 7.14ng/mL. 4-NPs were detected within all collected samples. The developed method allows accurate analysis of trace-level of EDCs in urine, and these target EDCs could act as useful biomarkers to assess exposure in biomonitoring studies and programs. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Preparation and value assignment of standard reference material 968e fat-soluble vitamins, carotenoids, and cholesterol in human serum.

    PubMed

    Thomas, Jeanice B; Duewer, David L; Mugenya, Isaac O; Phinney, Karen W; Sander, Lane C; Sharpless, Katherine E; Sniegoski, Lorna T; Tai, Susan S; Welch, Michael J; Yen, James H

    2012-01-01

    Standard Reference Material 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum provides certified values for total retinol, γ- and α-tocopherol, total lutein, total zeaxanthin, total β-cryptoxanthin, total β-carotene, 25-hydroxyvitamin D(3), and cholesterol. Reference and information values are also reported for nine additional compounds including total α-cryptoxanthin, trans- and total lycopene, total α-carotene, trans-β-carotene, and coenzyme Q(10). The certified values for the fat-soluble vitamins and carotenoids in SRM 968e were based on the agreement of results from the means of two liquid chromatographic methods used at the National Institute of Standards and Technology (NIST) and from the median of results of an interlaboratory comparison exercise among institutions that participate in the NIST Micronutrients Measurement Quality Assurance Program. The assigned values for cholesterol and 25-hydroxyvitamin D(3) in the SRM are the means of results obtained using the NIST reference method based upon gas chromatography-isotope dilution mass spectrometry and liquid chromatography-isotope dilution tandem mass spectrometry, respectively. SRM 968e is currently one of two available health-related NIST reference materials with concentration values assigned for selected fat-soluble vitamins, carotenoids, and cholesterol in human serum matrix. This SRM is used extensively by laboratories worldwide primarily to validate methods for determining these analytes in human serum and plasma and for assigning values to in-house control materials. The value assignment of the analytes in this SRM will help support measurement accuracy and traceability for laboratories performing health-related measurements in the clinical and nutritional communities.

  11. Automated on-line column-switching high performance liquid chromatography isotope dilution tandem mass spectrometry method for the quantification of bisphenol A, bisphenol F, bisphenol S, and 11 other phenols in urine.

    PubMed

    Zhou, Xiaoliu; Kramer, Joshua P; Calafat, Antonia M; Ye, Xiaoyun

    2014-01-01

    Human exposure to bisphenol A (BPA) is widespread. However, in recent years, bisphenol analogs such as bisphenol S (BPS) and bisphenol F (BPF) are replacing BPA in the production of some consumer products. Because human exposure to these alternative bisphenols may occur, biomonitoring of these bisphenol analogs is warranted. In the present study, we developed and validated a sensitive and selective method that uses on-line solid phase extraction coupled to high performance liquid chromatography-isotope dilution tandem mass spectrometry with peak focusing to measure BPA, BPF, BPS, and 11 other environmental phenols in urine. The method required a small amount of sample (100μL) and minimal sample pretreatment. The limits of detection were 0.03ng/mL (BPS), 0.06ng/mL (BPF), 0.10ng/mL (BPA), and ranged from 0.1ng/mL to 1.0ng/mL for the other 11 phenols. In 100 urine samples collected in 2009-2012 from a convenience group of anonymous adults in the United States, of the three bisphenols, we detected BPA at the highest frequency and median concentrations (95%, 0.72ng/mL), followed by BPS (78%, 0.13ng/mL) and BPF (55%, 0.08ng/mL). This sensitive, rugged, and labor and cost-effective method could be used for the analysis of large number of samples for epidemiologic studies. Published by Elsevier B.V.

  12. Effects of Iron and Nitrogen Limitation on Sulfur Isotope Fractionation during Microbial Sulfate Reduction

    PubMed Central

    Ono, Shuhei; Bosak, Tanja

    2012-01-01

    Sulfate-reducing microbes utilize sulfate as an electron acceptor and produce sulfide that is depleted in heavy isotopes of sulfur relative to sulfate. Thus, the distribution of sulfur isotopes in sediments can trace microbial sulfate reduction (MSR), and it also has the potential to reflect the physiology of sulfate-reducing microbes. This study investigates the relationship between the availability of iron and reduced nitrogen and the magnitude of S-isotope fractionation during MSR by a marine sulfate-reducing bacterium, DMSS-1, a Desulfovibrio species, isolated from salt marsh in Cape Cod, MA. Submicromolar levels of iron increase sulfur isotope fractionation by about 50% relative to iron-replete cultures of DMSS-1. Iron-limited cultures also exhibit decreased cytochrome c-to-total protein ratios and cell-specific sulfate reduction rates (csSRR), implying changes in the electron transport chain that couples carbon and sulfur metabolisms. When DMSS-1 fixes nitrogen in ammonium-deficient medium, it also produces larger fractionation, but it occurs at faster csSRRs than in the ammonium-replete control cultures. The energy and reducing power required for nitrogen fixation may be responsible for the reverse trend between S-isotope fractionation and csSRR in this case. Iron deficiency and nitrogen fixation by sulfate-reducing microbes may lead to the large observed S-isotope effects in some euxinic basins and various anoxic sediments. PMID:23001667

  13. Chromatographic speciation of Cr(III)-species, inter-species equilibrium isotope fractionation and improved chemical purification strategies for high-precision isotope analysis.

    PubMed

    Larsen, K K; Wielandt, D; Schiller, M; Bizzarro, M

    2016-04-22

    Chromatographic purification of chromium (Cr), which is required for high-precision isotope analysis, is complicated by the presence of multiple Cr-species with different effective charges in the acid digested sample aliquots. The differing ion exchange selectivity and sluggish reaction rates of these species can result in incomplete Cr recovery during chromatographic purification. Because of large mass-dependent inter-species isotope fractionation, incomplete recovery can affect the accuracy of high-precision Cr isotope analysis. Here, we demonstrate widely differing cation distribution coefficients of Cr(III)-species (Cr(3+), CrCl(2+) and CrCl2(+)) with equilibrium mass-dependent isotope fractionation spanning a range of ∼1‰/amu and consistent with theory. The heaviest isotopes partition into Cr(3+), intermediates in CrCl(2+) and the lightest in CrCl2(+)/CrCl3°. Thus, for a typical reported loss of ∼25% Cr (in the form of Cr(3+)) through chromatographic purification, this translates into 185 ppm/amu offset in the stable Cr isotope ratio of the residual sample. Depending on the validity of the mass-bias correction during isotope analysis, this further results in artificial mass-independent effects in the mass-bias corrected (53)Cr/(52)Cr (μ(53)Cr* of 5.2 ppm) and (54)Cr/(52)Cr (μ(54)Cr* of 13.5 ppm) components used to infer chronometric and nucleosynthetic information in meteorites. To mitigate these fractionation effects, we developed strategic chemical sample pre-treatment procedures that ensure high and reproducible Cr recovery. This is achieved either through 1) effective promotion of Cr(3+) by >5 days exposure to HNO3H2O2 solutions at room temperature, resulting in >∼98% Cr recovery for most types of sample matrices tested using a cationic chromatographic retention strategy, or 2) formation of Cr(III)-Cl complexes through exposure to concentrated HCl at high temperature (>120 °C) for several hours, resulting in >97.5% Cr recovery using a chromatographic elution strategy that takes advantage of the slow reaction kinetics of de-chlorination of Cr in dilute HCl at room temperature. These procedures significantly improve cation chromatographic purification of Cr over previous methods and allow for high-purity Cr isotope analysis with a total recovery of >95%. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Chromatographic speciation of Cr(III)-species, inter-species equilibrium isotope fractionation and improved chemical purification strategies for high-precision isotope analysis

    PubMed Central

    Larsen, K.K.; Wielandt, D.; Schiller, M.; Bizzarro, M.

    2016-01-01

    Chromatographic purification of chromium (Cr), which is required for high-precision isotope analysis, is complicated by the presence of multiple Cr-species with different effective charges in the acid digested sample aliquots. The differing ion exchange selectivity and sluggish reaction rates of these species can result in incomplete Cr recovery during chromatographic purification. Because of large mass-dependent inter-species isotope fractionation, incomplete recovery can affect the accuracy of high-precision Cr isotope analysis. Here, we demonstrate widely differing cation distribution coefficients of Cr(III)-species (Cr3+, CrCl2+ and CrCl2+) with equilibrium mass-dependent isotope fractionation spanning a range of ~1‰/amu and consistent with theory. The heaviest isotopes partition into Cr3+, intermediates in CrCl2+ and the lightest in CrCl2+/CrCl3°. Thus, for a typical reported loss of ~25% Cr (in the form of Cr3+) through chromatographic purification, this translates into 185 ppm/amu offset in the stable Cr isotope ratio of the residual sample. Depending on the validity of the mass-bias correction during isotope analysis, this further results in artificial mass-independent effects in the mass-bias corrected 53Cr/52Cr (μ53 Cr* of 5.2 ppm) and 54Cr/52Cr (μ54Cr* of 13.5 ppm) components used to infer chronometric and nucleosynthetic information in meteorites. To mitigate these fractionation effects, we developed strategic chemical sample pre-treatment procedures that ensure high and reproducible Cr recovery. This is achieved either through 1) effective promotion of Cr3+ by >5 days exposure to HNO3 —H2O2 solutions at room temperature, resulting in >~98% Cr recovery for most types of sample matrices tested using a cationic chromatographic retention strategy, or 2) formation of Cr(III)-Cl complexes through exposure to concentrated HCl at high temperature (>120 °C) for several hours, resulting in >97.5% Cr recovery using a chromatographic elution strategy that takes advantage of the slow reaction kinetics of de-chlorination of Cr in dilute HCl at room temperature. These procedures significantly improve cation chromatographic purification of Cr over previous methods and allow for high-purity Cr isotope analysis with a total recovery of >95%. PMID:27036208

  15. Silicon isotope ratio measurements by inductively coupled plasma tandem mass spectrometry for alteration studies of nuclear waste glasses.

    PubMed

    Gourgiotis, Alkiviadis; Ducasse, Thomas; Barker, Evelyne; Jollivet, Patrick; Gin, Stéphane; Bassot, Sylvain; Cazala, Charlotte

    2017-02-15

    High-level, long-lived nuclear waste arising from spent fuel reprocessing is vitrified in silicate glasses for final disposal in deep geologic formations. In order to better understand the mechanisms driving glass dissolution, glass alteration studies, based on silicon isotope ratio monitoring of 29 Si-doped aqueous solutions, were carried out in laboratories. This work explores the capabilities of the new type of quadrupole-based ICP-MS, the Agilent 8800 tandem quadrupole ICP-MS/MS, for accurate silicon isotope ratio determination for alteration studies of nuclear waste glasses. In order to avoid silicon polyatomic interferences, a new analytical method was developed using O 2 as the reaction gas in the Octopole Reaction System (ORS), and silicon isotopes were measured in mass-shift mode. A careful analysis of the potential polyatomic interferences on SiO + and SiO 2 + ion species was performed, and we found that SiO + ion species suffer from important polyatomic interferences coming from the matrix of sample and standard solutions (0.5M HNO 3 ). For SiO 2 + , no interferences were detected, and thus, these ion species were chosen for silicon isotope ratio determination. A number of key settings for accurate isotope ratio analysis like, detector dead time, integration time, number of sweeps, wait time offset, memory blank and instrumental mass fractionation, were considered and optimized. Particular attention was paid to the optimization of abundance sensitivity of the quadrupole mass filter before the ORS. We showed that poor abundance sensitivity leads to a significant shift of the data away from the Exponential Mass Fractionation Law (EMFL) due to the spectral overlaps of silicon isotopes combined with different oxygen isotopes (i.e. 28 Si 16 O 18 O + , 30 Si 16 O 16 O + ). The developed method was validated by measuring a series of reference solutions with different 29 Si enrichment. Isotope ratio trueness, uncertainty and repeatability were found to be <0.2%, <0.5% and <0.6%, respectively. These performances meet the requirements of the studies of nuclear glasses alteration and open up possibilities to use this method for precise determination of silicon content in natural samples by Isotope Dilution. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. One-step large-scale synthesis of micrometer-sized silver nanosheets by a template-free electrochemical method

    NASA Astrophysics Data System (ADS)

    Park, Sun Hwa; Son, Jin Gyeong; Lee, Tae Geol; Park, Hyun Min; Song, Jae Yong

    2013-05-01

    We have synthesized micrometer-sized Ag nanosheets via a facile, one-step, template-free electrochemical deposition in an ultra-dilute silver nitrate aqueous electrolyte. The nanosheet growth was revealed to occur in three stages: (1) formation of polygonal Ag nuclei on a substrate, (2) growth of {112}-faceted nanowire from the nuclei, and (3) anisotropic growth of (111)-planar nanosheets, approximately 20 to 50 nm in thickness and 10 μm in width, in the <112>-direction. The vertical growth of the facet nanowire was induced by the strong interface anisotropy between the deposit and electrolyte due to the ultra-dilute concentration of electrolyte and high reduction potential. The thickness of Ag nanosheets was controllable by the adjustment of the reduction/oxidation potential and frequency of the reverse-pulse potentiodynamic mode.

  17. Molecular differences between deuterated and protonated polystyrenes using reversed-phase high-performance liquid chromatography.

    PubMed

    Kayillo, Sindy; Gray, Michael J; Shalliker, R Andrew; Dennis, Gary R

    2005-05-06

    Isotopic substitution is a technique used to highlight particular bonds within a molecule for kinetic, spectroscopic and structure analysis. It is presumed that although some properties such as stretching frequencies will not be the same for substituted analogues, the chemical interactions will not vary appreciably as a function of labelling. Reversed-phase liquid chromatography has been used to demonstrate that there are significant differences between the chromatographic behaviour of a sequence of deuterated and protonated oligomeric polystyrenes. Two-dimensional reversed-phase liquid chromatography was used to show that even the diasteromers of the oligomers (n = 5) have retention mechanisms that are dependent on the subtle changes to the molecular conformation and electronic structure, which are a consequence of deuteration.

  18. The ID-KArD technique: In-situ dating on Mars

    NASA Astrophysics Data System (ADS)

    Cartwright, J. A.; Farley, K. A.; Hurowitz, J.; Asimow, P. D.; Jacobson, N. S.

    2013-12-01

    The ability to measure absolute ages on the Martian surface is crucial for understanding the planet's evolution. A detailed geological history of the Moon has been determined through analysis of returned samples from specific units, and relative ages calculated by crater counting techniques. However, without returned samples or in-situ dating analyses, we lack absolute age markers for Mars and thus cannot accurately or precisely date its well-documented surface. Instead, we have relied on an estimated Mars/Moon cratering ratio and relative crater counting techniques in an attempt to calculate surface ages and classify geological units. The use of such relative parameters diminishes the precision and accuracy for surface age calculations, and thus highlights the need for independent age determinations from returned samples or in-situ dating. In this research, we describe our technique - ID-KArD (Isotope Dilution K-Ar Dating) - intended for in-situ age dating of geological units on the Martian surface. ID-KArD resolves two challenges that have previously obstructed in-situ age dating on Mars: 1) High fusion temperatures are avoided with the use of a lithium-borate flux; 2) Sample mass measurement is not required, due to the addition of an isotope dilution doubly-spiked glass. The glass has a known 39Ar/41K ratio, which removes the need for concentration measurements. Thus, only isotope ratios are required for a K-Ar age determination. ID-KArD has the potential to address Mars chronology inaccuracies, and would be a suitable technique for consideration on future missions. In the first phase of ID-KArD proof of concept, we selected a Viluy trap basalt (K2O ~ 0.7 wt%), with concordant K-Ar and Ar-Ar ages of 354.3 × 3.5 and 357.7 × 1.4 Ma respectively (Courtillot et al., 2010). An aliquot was combined into a crucible with the flux and the spike glass for separate Ar (MAP 215:50, Caltech), followed by K (KEMS, GRC) isotopic analysis. Combining our results, we obtained an age of 351 × 19 Ma (Farley et al., 2013), in good agreement with the previously published ages. For the second phase, we have designed and built a single instrument, capable of analysing both Ar and K from a single sample. The instrument includes two ionisation sources for separate K (thermal) and Ar (electron impact) ionsiation, and a quadrupole mass spectrometer. In addition, we have designed a sample heating mechanism that allows degassing of flux prior to sample addition, and achieves temperatures in the range of the SAM oven on Curiosity. Thus far, the instrument has successfully measured both isotopic systems, and following further testing in the coming weeks, we will date Martian surface analogues, age standards, and finally meteoritic material.

  19. Development of Reverse Transcription Thermostable Helicase-Dependent DNA Amplification for the Detection of Tomato Spotted Wilt Virus.

    PubMed

    Wu, Xinghai; Chen, Chanfa; Xiao, Xizhi; Deng, Ming Jun

    2016-11-01

    A protocol for the reverse transcription-helicase-dependent amplification (RT-HDA) of isothermal DNA was developed for the detection of tomato spotted wilt virus (TSWV). Specific primers, which were based on the highly conserved region of the N gene sequence in TSWV, were used for the amplification of virus's RNA. The LOD of RT-HDA, reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP), and reverse transcriptase-polymerase chain reaction (RT-PCR) assays were conducted using 10-fold serial dilution of RNA eluates. TSWV sensitivity in RT-HDA and RT-LAMP was 4 pg RNA compared with 40 pg RNA in RT-PCR. The specificity of RT-HDA for TSWV was high, showing no cross-reactivity with other tomato and Tospovirus viruses including cucumber mosaic virus (CMV), tomato black ring virus (TBRV), tomato mosaic virus (ToMV), or impatiens necrotic spot virus (INSV). The RT-HDA method is effective for the detection of TSWV in plant samples and is a potential tool for early and rapid detection of TSWV.

  20. The size-isotopic evolution connection among layered mafic instrusions: Clues from a Sr-Nd isotopic study of a small complex

    NASA Astrophysics Data System (ADS)

    Poitrasson, Franck; Pin, Christian; Duthou, Jean-Louis; Platevoet, Bernard

    1994-05-01

    Several theoretical and experimental works have focused on the processes occuring in continental mafic magma chambers. In contrast, systematic isotopic studies of natural remnants of these latter remain scarce, although they can give fundamental constraints for theoretical studies. This is especially true if different layered complex with contrasting characteristics (e.g., different size) are compared. For this reason, we present the results of a Sr-Nd isotopic profile across a small layered mafic intrusion of Permian age exposed near Fozzano (SW Corsica). In the main zone of the layered section, decreasing Sr-87/Sr(sub i)-86 and increasing Nd-143/Nd(sub i)-144 are observed from less evolved (bottom) to more evolved (top) rocks. This peculiar pattern precludes assimilation and fractional crystallization (AFC) as a dominant mechanism in the petrogenesis of this body. Instead, we interpret this trend as reflecting the dilution of an early stage contaminated magma by several reinjections of fresh basalt in the chamber. In agreement with mineralogical and structural data, every cyclic unit is interpreted as a new magmatic input. On the basis of rough refill and fractional crystallization (RFC) calculations, the average volume for each reinjection is estimated to have been about 0.04 cu km. The cumulative volume of these injections would amount to about 75% of the total volume of the layered complex. This implies that reinjections were accompanied by an important increase of the volume of the chamber or by magma withdrawal by surface eruptions. The RFC mechanism documented within this small layered body constrasts with the isotopic pattern observed between several intrusions at the regional scale in SW Corsica, and within large continental mafic magma chambers elsewhere. In these cases the isotopic evolution is dominated by AFC processes, and there is no clear isotopic evidence for reinjections, unless major influx of fresh magma occurred. It is suggested that there is a close relationship between the assimilation rate and the magma chamber volume. Small magma chambers are quickly isolated from their country rocks and better preserve the subtle isotopic signature of reinjection processes.

  1. Proxies of Tropical Cyclone Isotope Spikes in Precipitation: Landfall Site Selection

    NASA Astrophysics Data System (ADS)

    Lawrence, J. R.; Maddocks, R.

    2011-12-01

    The human experience of climate change is not one of gradual changes in seasonal or yearly changes in temperature or rainfall. Despite that most paleoclimatic reconstructions attempt to provide just such information. Humans experience climate change on much shorter time scales. We remember hurricanes, weeks of drought or overwhelming rainy periods. Tropical cyclones produce very low isotope ratios in both rainfall and in atmospheric water vapor. Thus, climate proxies that potentially record these low isotope ratios offer the most concrete record of climate change to which humans can relate. The oxygen isotopic composition of tropical cyclone rainfall has the potential to be recorded in fresh water carbonate fossil material, cave deposits and corals. The hydrogen isotopic composition of tropical cyclone rainfall has the potential to be recorded in tree ring cellulose and organic matter in fresh water bodies. The Class of carbonate organisms known as Ostracoda form their carapaces very rapidly. Thus fresh water ephemeral ponds in the subtropics are ideal locations for isotopic studies because they commonly are totally dry when tropical cyclones make landfall. The other proxies suffer primarily from a dilution effect. The water from tropical cyclones is mixed with pre-existing water. In cave deposits tropical cyclone rains mix with soil and ground waters. In the near shore coral environment the rain mixes with seawater. For tree rings there are three sources of water: soil water, atmospheric water vapor that exchanges with leaf water and tropical cyclone rain. In lakes because of their large size rainfall runoff mixes with ground water and preexisting water in the lake. A region that shows considerable promise is Texas / Northeast Mexico. In a study of surface waters that developed from the passage of Tropical Storm Allison (2001) in SE Texas both the pond water and Ostracoda that bloomed recorded the low oxygen isotope signal of that storm (Lawrence et al, 2008). In 2010 rain from Hurricane Alex, Tropical Depression 2 and Tropical Storm Hermine flooded ephemeral ponds in south Texas. Isotopic analysis of water and fossil Ostracoda from ephemeral ponds in south Texas is planned. Cores (50 cm in length) were taken in one of these ponds where living Ostracoda were found and collected.

  2. Mass Dependent Fractionation of Hg Isotopes in Source Rocks, Mineral Deposits and Spring Waters of the California Coast Ranges, USA

    NASA Astrophysics Data System (ADS)

    Smith, C. N.; Kesler, S. E.; Blum, J. D.; Rytuba, J. J.

    2007-12-01

    We present here the first study of the isotopic composition of Hg in rocks, ore deposits, and active hydrothermal systems from the California Coast Ranges, one of Earth's largest Hg-depositing systems. The Franciscan Complex and Great Valley Sequence, which form the bedrock in the California Coast Ranges, are intruded and overlain by Tertiary volcanic rocks including the Clear Lake Volcanic Sequence. These rocks contain two types of Hg deposits, hot-spring deposits that form at shallow depths (<300 m) and silica-carbonate deposits that extend to greater depths (200 to 1000 m), as well as active springs and geothermal systems that release Hg to the present surface. The Franciscan Complex and Great Valley Sequence contain clastic sedimentary rocks with higher concentrations of Hg than volcanic rocks of the Clear Lake Volcanic Field. Mean Hg isotope compositions for all three rock units are similar, although the range of values in Franciscan Complex rocks is greater than in either Great Valley or Clear Lake rocks. Hot spring and silica-carbonate Hg deposits have similar average isotopic compositions that are indistinguishable from averages for the three rock units, although δ202Hg values for the Hg deposits have a greater variance than the country rocks. Precipitates from dilute spring and saline thermal waters in the area have similarly large variance and a mean δ202Hg value that is significantly lower than the ore deposits and rocks. These observations indicate there is little or no isotopic fractionation during release of Hg from its source rocks into hydrothermal solutions. Isotopic fractionation does appear to take place during transport and concentration of Hg in deposits, especially in their uppermost parts. Boiling of hydrothermal fluids is likely the most important process causing of the observed Hg isotope fractionation. This should result in the release of Hg with low δ202Hg values into the atmosphere from the top of these hydrothermal systems and a consequent enrichment in heavy Hg isotopes in the upper crust through time.

  3. Effect of sample preparation techniques for carbon and nitrogen stable isotope analysis of hydroxyapatite structures in the form of elasmobranch vertebral centra.

    PubMed

    Christiansen, Heather M; Hussey, Nigel E; Wintner, Sabine P; Cliff, Geremy; Dudley, Sheldon F J; Fisk, Aaron T

    2014-03-15

    Bulk stable isotope analysis (SIA) provides an important tool for the study of animal ecology. Elasmobranch vertebral centra can be serially sampled to obtain an isotopic history of an individual over ontogeny. The measured total δ(13)C value, however, may be misinterpreted due to the inclusion of the (13)C-rich inorganic portion. Hydrochloric acid (HCl) is commonly used to remove the inorganic portion of hydroxyapatite structures before undertaking SIA, but more recently ethylenediaminetetraacetic acid (EDTA) has been recommended for elasmobranch vertebrae. These acid treatments may introduce uncertainty on measured δ(13)C and δ(15)N values above instrument precision and the effect of small sample size remains untested for elasmobranch vertebrae. Using a non-dilution program on an isotope ratio mass spectrometer the minimum sample weight of vertebrae required to obtain accurate isotopic values was determined for three shark species: white (Carcharodon carcharias), tiger (Galeocerdo cuvier), and sand tiger (Carcharias taurus). To examine if acid treatment completely removes the inorganic component of the vertebrae or whether the technique introduces its own uncertainty on measured δ(13)C and δ(15)N values, vertebrae samples were analyzed untreated and following EDTA treatment. The minimum sample weight required for accurate stable isotope values and the percentage sample yield following EDTA treatment varied within and among species. After EDTA treatment, white shark vertebrae were all enriched in (13)C and depleted in (15) N, tiger shark vertebrae showed both enrichment and depletion of (13)C and (15)N, and sand tiger shark vertebrae were all depleted in (13)C and (15)N. EDTA treatment of elasmobranch vertebrae produces unpredictable effects (i.e. non-linear and non-correctable) among species in both the percentage sample yield and the measured δ(13)C and δ(15)N values. Prior to initiating a large-scale study, we strongly recommend investigating (i) the minimum weight of vertebral material required to obtain consistent isotopic values and (ii) the effects of EDTA treatment, specific to the study species and the isotope ratio mass spectrometer employed. Copyright © 2014 John Wiley & Sons, Ltd.

  4. Development and evaluation of a suite of isotope reference gases for methane in air

    NASA Astrophysics Data System (ADS)

    Sperlich, Peter; Uitslag, Nelly A. M.; Richter, Jürgen M.; Rothe, Michael; Geilmann, Heike; van der Veen, Carina; Röckmann, Thomas; Blunier, Thomas; Brand, Willi A.

    2016-08-01

    Measurements from multiple laboratories have to be related to unifying and traceable reference material in order to be comparable. However, such fundamental reference materials are not available for isotope ratios in atmospheric methane, which led to misinterpretations of combined data sets in the past. We developed a method to produce a suite of synthetic CH4-in-air standard gases that can be used to unify methane isotope ratio measurements of laboratories in the atmospheric monitoring community. Therefore, we calibrated a suite of pure methane gases of different methanogenic origin against international referencing materials that define the VSMOW (Vienna Standard Mean Ocean Water) and VPDB (Vienna Pee Dee Belemnite) isotope scales. The isotope ratios of our pure methane gases range between -320 and +40 ‰ for δ2H-CH4 and between -70 and -40 ‰ for δ13C-CH4, enveloping the isotope ratios of tropospheric methane (about -85 and -47 ‰ for δ2H-CH4 and δ13C-CH4 respectively). Estimated uncertainties, including the full traceability chain, are < 1.5 ‰ and < 0.2 ‰ for δ2H and δ13C calibrations respectively. Aliquots of the calibrated pure methane gases have been diluted with methane-free air to atmospheric methane levels and filled into 5 L glass flasks. The synthetic CH4-in-air standards comprise atmospheric oxygen/nitrogen ratios as well as argon, krypton and nitrous oxide mole fractions to prevent gas-specific measurement artefacts. The resulting synthetic CH4-in-air standards are referred to as JRAS-M16 (Jena Reference Air Set - Methane 2016) and will be available to the atmospheric monitoring community. JRAS-M16 may be used as unifying isotope scale anchor for isotope ratio measurements in atmospheric methane, so that data sets can be merged into a consistent global data frame.

  5. Assessment of body fat in the pony: part II. Validation of the deuterium oxide dilution technique for the measurement of body fat.

    PubMed

    Dugdale, A H A; Curtis, G C; Milne, E; Harris, P A; Argo, C Mc

    2011-09-01

    Excessive accumulations or depletions of body fat have been associated with increased morbidity and mortality in horses and ponies. An objective, minimally-invasive method to accurately quantify body fat in living animals is required to aid nutritional management and define welfare/performance limits. To compare deuterium oxide (D(2) O) dilution-derived estimates of total body water (TBW) and body fat with values obtained by 'gold standard' proximate analysis and cadaver dissection. D(2) O dilution offers a valid method for the determination of TBW and body fat in equids. Seven mature (mean ± s.e. 13 ± 3 years, 212 ± 14 kg, body condition scores 1.25-7/9), healthy, Welsh Mountain pony mares, destined for euthanasia (for nonresearch purposes) were used. Blood samples were collected before and 4 h after D(2) O (0.11-0.13 g/kg bwt, 99.8 atom percent excess) administration. Plasma was analysed by gas isotope ratio mass spectrometry following filtration and zinc reduction. After euthanasia, white adipose tissue (WAT) mass was recorded before all body tissues were analysed by proximate chemical analyses. D(2) O-derived estimates of TBW and body fat were strongly associated with proximate analysis- and dissection-derived values (all r(2) >0.97, P≤0.0001). Bland-Altman analyses demonstrated good agreements between methods. D(2) O dilution slightly overestimated TBW (0.79%, limits of agreement (LoA) -3.75-2.17%) and underestimated total body lipid (1.78%, LoA -0.59-4.15%) and dissected WAT (0.72%, LoA -2.77-4.21%). This study provides the first validation of the D(2) O dilution method for the minimally-invasive, accurate, repeatable and objective measurement of body water and fat in living equids. © 2011 EVJ Ltd.

  6. Motor Cortex Stimulation Reverses Maladaptive Plasticity Following Spinal Cord Injury

    DTIC Science & Technology

    2011-09-01

    Additional anesthesia (10 mg/kg intraperitoneal, diluted ketamine 1:10 in saline) was administered whenneeded. Local anesthetic (2% lidocaine)was applied to...cord lesion. Under aseptic conditions, and using ketamine/xylazine anesthesia Figure 5. A representative example of a PO neuron in response to the... localized (Task 1b). • We found that the majority of ZI units enhanced by MCS receive direct inputs from the motor cortex (Task 1b). • We

  7. Bistability in Doped Organic Thin Film Transistors (Preprint)

    DTIC Science & Technology

    2007-03-01

    small molecules (e.g. pentacene ). As such, they do not necessarily compete with these more typical organic transistors, but rather have pertinence...involves dipping a substrate between two dilute polyelectrolyte solutions of opposite charge to build up a thin film via the electrostatic interactions...recovery is due to trapped O2(g) remaining in the film, which causes the reverse of reaction (1) to occur and the concomitant increase in the level of

  8. A Comparative Analysis of the Influence of Surface Mining on Hydrological and Geochemical Response of Selected Headwater Streams in the Elk Valley, British Columbia, Canada.

    NASA Astrophysics Data System (ADS)

    Carey, S. K.; Shatilla, N. J.; Szmudrowska, B.; Rastelli, J.; Wellen, C.

    2014-12-01

    Surface mining is a common method of accessing coal. Blasting of overburden rock allows access to mineable ore. In high-elevation environments, the removed overburden rock is deposited in adjacent valleys as waste rock spoils. As part of a multi-year R&D program examining the influence of surface mining on watershed hydrological and water quality responses in the Elk Valley, British Columbia, this study reports on how surface mining affects streamflow hydrological and geochemical response at four reference and four mine-influenced catchments. The hydrology of this environment is dominated by snowmelt and steep topographic gradients. Flows were attenuated in mine-influenced catchments, with spring freshet delayed and more muted responses to precipitation events observed. Dissolved ions were an order of magnitude greater in mine-influenced streams, with more dilution-based responses to flows compared with chemostatic behavior observed in reference streams. Stable isotope signatures in stream water suggested that in both mine-influenced and reference watersheds, stream water was derived from well mixed groundwater as annual variability of stream isotope signatures was dampened compared with precipitation signatures. However, deflection of stream isotopes in response to precipitation were more apparent in reference watersheds. As a group, mine influenced catchments had a heavier isotope signature than reference watersheds, suggesting an enhanced influence of rainfall on recharge. Transit time distributions indicate existing waste rock spoils increase the average time water takes to move through the catchment.

  9. Determination of lead, cadmium, indium, thallium and silver in ancient ices from Antarctica by isotope dilution-thermal ionization mass spectrometry

    USGS Publications Warehouse

    Matsumoto, A.; Hinkley, T.K.

    1997-01-01

    The concentrations of five chalcophile elements (Pb, Cd, In, Tl and Ag) and the lead isotope rarios in ancient ices from the Taylor Dome near coastal Antarctica, have been determined by the isotope dilutionthermal ionization mass spectrometry (ID-TIMS), with ultra-clean laboratory techniques. The samples were selected from segments of cores, one of which included a visible ash layer. Electric conductivity measurement (ECM) or dielectric properties (DEP) gave distinctive sharp peaks for some of the samples c hosen. Exterior portions of the sample segments were trimmed away by methods described here. Samples w ere evaporated to dryness and later separated into fractions for the five elements using an HBr-HNO3 a nion exchange column method. The concentrations are in the range 2.62-36.7 pg Pb/g of ice, 0.413-2.83 pg Cd/g, 0.081-0.34 pg In/g, 0.096-2.8 pg Tl/g and 0.15-0.84 pg Ag/g. respectively. The dispersions in duplicate analyses are about ??1% for lead and cadmium, ??2% for indium. ??4% for thallium and ??6% for silver, respectively. The concentrations of lead obtained are commonly higher than those in the present-day Antarctic surface snows, but the isotope ratios are distinctively higher than those of the present-day snows and close to those of the other ancient ice collected from a different Antarctic area.

  10. Hydrologic exchanges and baldcypress water use on deltaic hummocks, Louisiana, USA

    USGS Publications Warehouse

    Hsueh, Yu-Hsin; Chambers, Jim L.; Krauss, Ken W.; Allen, Scott T.; Keim, Richard F.

    2016-01-01

    Coastal forested hummocks support clusters of trees in the saltwater–freshwater transition zone. To examine how hummocks support trees in mesohaline sites that are beyond physiological limits of the trees, we used salinity and stable isotopes (2H and 18O) of water as tracers to understand water fluxes in hummocks and uptake by baldcypress (Taxodium distichum (L.) Rich.), which is the most abundant tree species in coastal freshwater forests of the southeastern U.S. Hummocks were always partially submerged and were completely submerged 1 to 8% of the time during the two studied growing seasons, in association with high water in the estuary. Salinity, δ18O, and δ2H varied more in the shallow open water than in groundwater. Surface water and shallow groundwater were similar to throughfall in isotopic composition, which suggested dominance by rainfall. Salinity of groundwater in hummocks increased with depth, was higher than in swales, and fluctuated little over time. Isotopic composition of xylem water in baldcypress was similar to the vadose zone and unlike other measured sources, indicating that trees preferentially use unsaturated hummock tops as refugia from higher salinity and saturated soil in swales and the lower portions of hummocks. Sustained upward gradients of salinity from groundwater to surface water and vadose water, and low variation in groundwater salinity and isotopic composition, suggested long residence time, limited exchange with surface water, and that the shallow subsurface of hummocks is characterized by episodic salinization and slow dilution.

  11. Influence of molecular electronic properties on the IR spectra of dimeric hydrogen bond systems: polarized spectra of 2-hydroxybenzothiazole and 2-mercaptobenzothiazole crystals

    NASA Astrophysics Data System (ADS)

    Flakus, Henryk T.; Miros, Artur; Jones, Peter G.

    2002-01-01

    We have studied the polarized IR spectra of the hydrogen-bonded molecular crystals of 2-hydroxybenzothiazole (HBT) and 2-mercaptobenzothiazole (MBT). The crystal structure of 2-hydroxybenzothiazole was determined by X-ray diffraction. The polarized spectra of the crystals were measured, in the frequency ranges of the νN-H and νN-D bands, at room temperature, and at 77 K. In both systems an extremely strong H/D isotopic effect in the spectra was observed, involving reduction of the well-developed νN-H band fine structure to a single prominent νN-D line only. The two νN-H bands were also shown to exhibit almost identical properties, band shapes, temperature and dichroic properties included. The spectra were quantitatively reconstituted, along with the strong isotopic effect, when calculated using the 'strong-coupling' theory, assuming the centrosymmetric dimers of HBT or MBT to be the structural units responsible for the crystalline spectral properties. The similarity of the spectra of the two crystalline systems was considered to be a result of longer-distance couplings between the proton vibrations in the dimers, via the aromatic ring electrons. When investigating the 'residual' νN-H band shapes for crystals isotopically diluted by deuterium, we observed some 'self-organization' effects in the spectra, indicating the energetically favored presence of two identical hydrogen isotopes in each hydrogen bond dimer.

  12. Seventh Annual V. M. Goldschmidt Conference

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Topics considered include: Subduction of the Aseismic Cocos Ridge Displaced Magma Sources Beneath the Cordillera de Talamanca, Costa Rica; Topography of Transition Zone Discontinuities: A Measure of 'Olivine' Content and Evidence for Deep Cratonic Roots; Uranium Enrichment in Lithospheric Mantle: Case Studies from French Massif Central; Rare-Earth-Element Anomalies in the Decollement Zone of the nankai Accretionary Prism, Japan: Evidence of Fluid Flow?; Rare Earth Elements in Japanese Mudrocks: The Influence of Provenance; The Evolution of Seawater Strontium Isotopes in the Last Hundred Million Years: Reinterpretation and Consequences for Erosion and Climate Models; From Pat to Tats: The Lead Isotope Legacy in the Studies of the Continental Crust-Upper Mantle System; Geochronology of the Jack Hills Detrital Zircons by Precise Uranium-Lead Isotope-Dilution Analysis of Crystal Fragments; Iridium in the Oceans; The Helium-Heat-Lead Paradox; Control of Distribution Patterns of Heavy Metals in Ganga Plain Around Kanpur Region, India, by Fluvial Geomorphic Domains; Geochemical and Isotopic Features of Ferrar Magmatic Provience (Victoria Land, Antarctica); Rare Earth Elements in Marine Fine-Grained Sediments from the Northwestern Portuguese Shelf (Atlantic); Aspects of Arc Fluxes; General Kinetic Model for Dolomite Precipitation Rate with Application to the Secular History of Seawater Composition; High-Precision Uranium-series Chronology from Speleothems; Trace-Element Modeling of Aqueous Fluid-Peridotite Interaction in the Mantle Wedge of Subduction Zones; Rainfall Variations in Southeastern Australia over the Last 500,000 Years from Speleothem Deposition; The Role of Water in High-Pressure Fluids; The Kinetic Conditions of Metamorphic Minearogenesis: Evidence from Minerals and Assemblages.

  13. First results of a simultaneous measurement of tritium and 14C in an ultra-low-background proportional counter for environmental sources of methane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mace, Emily K.; Aalseth, Craig E.; Day, Anthony R.

    Abstract Simultaneous measurement of tritium and 14C would provide an added tool for tracing organic compounds through environmental systems and is possible via beta energy spectroscopy of sample-derived methane in internal-source gas proportional counters. Since the mid-1960’s atmospheric tritium and 14C have fallen dramatically as the isotopic injections from above-ground nuclear testing have been diluted into the ocean and biosphere. In this work, the feasibility of simultaneous tritium and 14C measurements via proportional counters is revisited in light of significant changes in both the atmospheric and biosphere isotopics and the development of new ultra-low-background gas proportional counting capabilities for smallmore » samples (roughly 50 cc methane). A Geant4 Monte Carlo model of a Pacific Northwest National Laboratory (PNNL) proportional counter response to tritium and 14C is used to analyze small samples of two different methane sources to illustrate the range of applicability of contemporary simultaneous measurements and their limitations. Because the two methane sources examined were not sample size limited, we could compare the small-sample measurements performed at PNNL with analysis of larger samples performed at a commercial laboratory. The dual-isotope simultaneous measurement is well matched for methane samples that are atmospheric or have an elevated source of tritium (i.e. landfill gas). For samples with low/modern tritium isotopics (rainwater), commercial separation and counting is a better fit.« less

  14. Geochemistry of Apollo 15 basalt 15555 and soil 15531.

    NASA Technical Reports Server (NTRS)

    Schnetzler, C. C.; Philpotts, J. A.; Nava, D. F.; Schuhmann, S.; Thomas, H. H.

    1972-01-01

    Data are presented on major and trace element concentrations determined by atomic absorption spectrophotometry, colorimetry, and isotope dilution in Apollo 15 mare basalt 15555 from the Hadley Rille area, as well as on trace element concentrations determined in plagioclase and pyroxene separates from basalt 15555 and in soil 15531 from the same area. Most of the chemical differences between basalt 15555 and soil 15531 could be accounted for if the soil were a mixture of 88% basalt, 6% KREEP (a component, identified in other Apollo soils, rich in potassium, rare-earth elements, and phosphorus), and 6% plagioclase.

  15. Determination of Trace Level Iodine in Biological and Botanical Reference Materials by Isotope Dilution Mass Spectrometry

    PubMed Central

    Gramlich, John W.; Murphy, Thomas J.

    1989-01-01

    A method has been developed for the determination of trace level iodine in biological and botanical materials. The method consists of spiking a sample with 129I, equilibration of the spike with the natural iodine, wet ashing under carefully controlled conditions, and separation of the iodine by co-precipitation with silver chloride. Measurement of the 129I/127I ratio is accomplished by negative thermal ionization mass spectrometry using LaB6 for ionization enhancement. The application of the method to the certification of trace iodine in two Standard Reference Materials is described. PMID:28053411

  16. Atmospheric plume progression as a function of time and distance from the release point for radioactive isotopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eslinger, Paul W.; Bowyer, Ted W.; Cameron, Ian M.

    2015-10-01

    The International Monitoring System contains up to 80 stations around the world that have aerosol and xenon monitoring systems designed to detect releases of radioactive materials to the atmosphere from nuclear tests. A rule of thumb description of plume concentration and duration versus time and distance from the release point is useful when designing and deploying new sample collection systems. This paper uses plume development from atmospheric transport modeling to provide a power-law rule describing atmospheric dilution factors as a function of distance from the release point.

  17. High Throughput Determination of VX in Drinking Water by ...

    EPA Pesticide Factsheets

    Methods Report This document provides the standard operating procedure for determination of the chemical warfare agent VX (O-Ethyl S-2-Diisopropylamino-Ethyl Methylphosphonothioate) in drinking water by isotope dilution liquid chromatography tandem mass spectrometer (LC/MS/MS). This method was adapted from one that was initially developed by the Centers for Disease Control and Prevention, in the National Center for Environmental Health for the determination and quantitation of VX in aqueous matrices. This method is designed to support site-specific cleanup goals of environmental remediation activities following a homeland security incident involving this analyte.

  18. Predicting water quality changes from artificial recharge sources to nearby wellfields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moran, J.E.

    1998-01-23

    Isotope tracer technologies have proven to be powerful tools for addressing questions related to surface water-ground water interactions. The Alameda County Water District artificially recharges tens of thousands of acre-ft of water annually, delivered from Alameda Creek in order to augment dwindling ground water supplies, and to maintain a barrier to seawater intrusion. The authors are using a suite of isotope tracers to track water movement, source characteristics and accompanying water quality changes from ACWD recharge facilities to nearby wells. The data gathered during the three year project will allow quantification of dilution by ambient basin ground water, subsurface travelmore » times, and several key water quality parameters, including degree of degradation of organic compounds, the fate of trace metals during recharge and subsurface transport, and sources and transport of major ions (salts). Reconnaissance work was carried out on naturally occurring isotopes in order to better understand the hydrogeology of the ground water basin. The basin is dissected by the Hayward Fault, and geologic conditions vary greatly on either side of the fault. Stable isotopes of oxygen, carbon, helium and other noble gases, along with radiocarbon and tritium were measured on water samples from production and monitoring wells. The goal of the reconnaissance work was to age date the water at various depths and distances from the recharge ponds, to examine the chemical evolution of the water with age, and to examine the water for source-related variations in isotope composition. Ground water ages were calculated by the tritium-helium method for three production wells in the Peralta-Tyson wellfield (in the Above Hayward Fault sub-basin), and for a monitoring well positioned between the recharge facilities and production wells, screened at three discreet intervals.« less

  19. Improved sample preparation of glyphosate and methylphosphonic acid by EPA method 6800A and time-of-flight mass spectrometry using novel solid-phase extraction.

    PubMed

    Wagner, Rebecca; Wetzel, Stephanie J; Kern, John; Kingston, H M Skip

    2012-02-01

    The employment of chemical weapons by rogue states and/or terrorist organizations is an ongoing concern in the United States. The quantitative analysis of nerve agents must be rapid and reliable for use in the private and public sectors. Current methods describe a tedious and time-consuming derivatization for gas chromatography-mass spectrometry and liquid chromatography in tandem with mass spectrometry. Two solid-phase extraction (SPE) techniques for the analysis of glyphosate and methylphosphonic acid are described with the utilization of isotopically enriched analytes for quantitation via atmospheric pressure chemical ionization-quadrupole time-of-flight mass spectrometry (APCI-Q-TOF-MS) that does not require derivatization. Solid-phase extraction-isotope dilution mass spectrometry (SPE-IDMS) involves pre-equilibration of a naturally occurring sample with an isotopically enriched standard. The second extraction method, i-Spike, involves loading an isotopically enriched standard onto the SPE column before the naturally occurring sample. The sample and the spike are then co-eluted from the column enabling precise and accurate quantitation via IDMS. The SPE methods in conjunction with IDMS eliminate concerns of incomplete elution, matrix and sorbent effects, and MS drift. For accurate quantitation with IDMS, the isotopic contribution of all atoms in the target molecule must be statistically taken into account. This paper describes two newly developed sample preparation techniques for the analysis of nerve agent surrogates in drinking water as well as statistical probability analysis for proper molecular IDMS. The methods described in this paper demonstrate accurate molecular IDMS using APCI-Q-TOF-MS with limits of quantitation as low as 0.400 mg/kg for glyphosate and 0.031 mg/kg for methylphosphonic acid. Copyright © 2012 John Wiley & Sons, Ltd.

  20. Amino Acid Selective 13C Labeling and 13C Scrambling Profile Analysis of Protein α and Side-Chain Carbons in Escherichia coli Utilized for Protein Nuclear Magnetic Resonance.

    PubMed

    Sugiki, Toshihiko; Furuita, Kyoko; Fujiwara, Toshimichi; Kojima, Chojiro

    2018-06-20

    Amino acid selective isotope labeling is an important nuclear magnetic resonance technique, especially for larger proteins, providing strong bases for the unambiguous resonance assignments and information concerning the structure, dynamics, and intermolecular interactions. Amino acid selective 15 N labeling suffers from isotope dilution caused by metabolic interconversion of the amino acids, resulting in isotope scrambling within the target protein. Carbonyl 13 C atoms experience less isotope scrambling than the main-chain 15 N atoms do. However, little is known about the side-chain 13 C atoms. Here, the 13 C scrambling profiles of the Cα and side-chain carbons were investigated for 15 N scrambling-prone amino acids, such as Leu, Ile, Tyr, Phe, Thr, Val, and Ala. The level of isotope scrambling was substantially lower in 13 Cα and 13 C side-chain labeling than in 15 N labeling. We utilized this reduced scrambling-prone character of 13 C as a simple and efficient method for amino acid selective 13 C labeling using an Escherichia coli cold-shock expression system and high-cell density fermentation. Using this method, the 13 C labeling efficiency was >80% for Leu and Ile, ∼60% for Tyr and Phe, ∼50% for Thr, ∼40% for Val, and 30-40% for Ala. 1 H- 15 N heteronuclear single-quantum coherence signals of the 15 N scrambling-prone amino acid were also easily filtered using 15 N-{ 13 Cα} spin-echo difference experiments. Our method could be applied to the assignment of the 55 kDa protein.

Top