Engineering of a multi-station shoulder simulator.
Smith, Simon L; Li, Lisa; Joyce, Thomas J
2016-05-01
This work aimed to engineer a multi-station shoulder simulator in order to wear test shoulder prostheses using recognized shoulder activities of daily living. A bespoke simulator was designed, built and subject to commissioning trials before a first wear test was conducted. Five JRI Orthopaedics Reverse Shoulder VAIOS 42 mm prostheses were tested for 2.0 million cycles and a mean wear rate and standard deviation of 14.2 ± 2.1 mm(3)/10(6) cycles measured for the polymeric glenoid components. This result when adjusted for prostheses diameters and test conditions showed excellent agreement with results from hip simulator studies of similar materials in a lubricant of bovine serum. The Newcastle Shoulder Simulator is the first multi-station shoulder simulator capable of applying physiological motion and loading for typical activities of daily living. © IMechE 2016.
Emerging Indications for Reverse Shoulder Arthroplasty.
Urch, Ekaterina; Dines, Joshua S; Dines, David M
2016-01-01
Historically, reverse shoulder arthroplasty was reserved for older, low-demand patients in whom rotator cuff arthropathy was diagnosed. Other common indications included sequelae of previously treated proximal humerus fractures, failed anatomic total shoulder arthroplasty, tumor resection, and rheumatoid arthritis in the elderly population. Unpredictable implant durability and high complication rates have limited the use of reverse shoulder arthroplasty to a narrow group of patients. Over the past decade, however, research has led to an improved understanding of the biomechanics behind reverse shoulder prostheses, which has improved implant design and surgical techniques. Consequently, orthopaedic surgeons have slowly begun to expand the indications for reverse shoulder arthroplasty to include a wider spectrum of shoulder pathologies. Recent studies have shown promising results for patients who undergo reverse shoulder arthroplasty for the treatment of acute proximal humerus fractures, massive rotator cuff tears without arthropathy, primary osteoarthritis, and chronic anterior dislocation, as well as for younger patients who have rheumatoid arthritis. These data suggest that, with judicious patient selection, reverse shoulder arthroplasty can be an excellent treatment option for a growing patient cohort.
de Toledo, Joelly Mahnic; Loss, Jefferson Fagundes; Janssen, Thomas W; van der Scheer, Jan W; Alta, Tjarco D; Willems, W Jaap; Veeger, DirkJan H E J
2012-10-01
Following shoulder arthroplasty, any well-planned rehabilitation program should include muscle strengthening. However, it is not always clear how different external loads influence shoulder kinematics in patients with shoulder prostheses. The objective of this study was to describe shoulder kinematics and determine the contribution of the scapulothoracic joint to total shoulder motion of patients with total and reverse shoulder arthroplasties and of healthy individuals during rehabilitation exercises (anteflexion and elevation in the scapular plane) using different loading conditions (without external load, 1 kg and elastic resistance). Shoulder motions were measured using an electromagnetic tracking device. A force transducer was used to record force signals during loaded conditions using elastic resistance. Statistical comparisons were made using a three-way repeated-measures analysis of variance with a Bonferroni post hoc testing. The scapula contributed more to movement of the arm in subjects with prostheses compared to healthy subjects. The same applies for loaded conditions (1 kg and elastic resistance) relative to unloaded tasks. For scapular internal rotation, upward rotation and posterior tilt no significant differences among groups were found during both exercises. Glenohumeral elevation angles during anteflexion were significantly higher in the total shoulder arthroplasty group compared to the reverse shoulder arthroplasty group. Differences in contribution of the scapula to total shoulder motion between patients with different types of arthroplasties were not significant. However, compared to healthy subjects, they were. Furthermore, scapular kinematics of patients with shoulder arthroplasty was influenced by implementation of external loads, but not by the type of load. Copyright © 2012 Elsevier Ltd. All rights reserved.
Two-stage reimplantation for treating prosthetic shoulder infections.
Sabesan, Vani J; Ho, Jason C; Kovacevic, David; Iannotti, Joseph P
2011-09-01
Two-stage reimplantation for prosthetic joint infection reportedly has the lowest risk for recurrent infection. Most studies to date have evaluated revision surgery for infection using an anatomic prosthetic. As compared with anatomic prostheses, reverse total shoulder arthroplasty is reported to have a higher rate of infection. We determined reinfection rates, functional improvement, types and rates of complications, and influence of rotator cuff tissue on function for two-stage reimplantation for prosthetic joint infection treated with reverse shoulder arthroplasty. We retrospectively reviewed 27 patients treated with a two-stage reimplantation for prosthetic shoulder infection using a uniform protocol for management of infection; of these, 17 had reverse shoulder arthroplasty at second-stage surgery. Types of organisms cultured, recurrence rates, complications, function, and radiographic followup were reviewed for all patients. One of the 17 patients had recurrence of infection. The mean (± SD) Penn shoulder scores for patients treated with reverse shoulder arthroplasty improved from 24.9 ± 22.3 to 66.4 ± 20.8. The average motion at last followup was 123° ± 33° of forward flexion and 26° ± 8° of external rotation in patients treated with a reverse shoulder arthroplasty. The major complication rate was 35% in reverse shoulder arthroplasty, with five dislocations and one reinfection. There was no difference in final Penn score between patients with and without external rotation weakness. Shoulder function and pain improved in patients treated with a second-stage reimplantation of a reverse prosthesis and the reinfection rate was low. Level IV, case series. See Guidelines for Authors for a complete description of levels of evidence.
Alta, Tjarco D W; Veeger, DirkJan H E J; de Toledo, Joelly M; Janssen, Thomas W J; Willems, W Jaap
2014-11-01
Range of motion after total shoulder arthroplasty is better than after reverse shoulder arthroplasty, however with similar clinical outcome. It is unclear if this difference can only be found in the different range of motion or also in the force generating capacity. (1) are isokinetically produced joint torques of reverse shoulder arthroplasty comparable to those of total shoulder arthroplasty? (2) Does this force-generating capacity correlate with functional outcome? Eighteen reverse shoulder arthroplasty patients (71years (SD 9years)) (21 shoulders, follow-up of 21months (SD 10months)) were recruited, 12 total shoulder arthroplasty patients (69years (SD 9years)) (14 shoulders, follow-up of 35months (SD 11months)). Pre- and post-operative Constant-Murley scores were obtained; two isokinetic protocols (ab-/adduction and ex-/internal rotations) at 60°/s were performed. Twelve of 18 reverse shoulder arthroplasty patients generated enough speed to perform the test (13 shoulders). Mean ab-/adduction torques are 16.3Nm (SD 5.6Nm) and 20.4Nm (SD 11.8Nm). All total shoulder arthroplasty patients generated enough speed (14 shoulders). Mean ab-/adduction torques are 32.1Nm (SD 13.3Nm) and 43.1Nm (SD 21.5Nm). Only 8 reverse shoulder arthroplasty patients (9 shoulders) could perform ex-/internal rotation tasks and all total shoulder arthroplasty patients. Mean ex-/internal rotation torques are 9.3Nm (SD 4.7Nm) and 9.2Nm (SD 2.1Nm) for reverse shoulder arthroplasty, and 17.9Nm (SD 7.7Nm) and 23.5Nm (SD 10.6Nm) for total shoulder arthroplasty. Significant correlations between sub-scores: activity, mobility and strength and external rotation torques for reverse shoulder arthroplasty. Moderate to strong correlation for sub-scores: strength in relation to abduction, adduction and internal rotation torques for total shoulder arthroplasty. Shoulders with a total shoulder arthroplasty are stronger. This can be explained by the absence of rotator cuff muscles and (probably) medialized center of rotation in reverse shoulder arthroplasty. The strong correlation between external rotation torques and post-operative Constant-Murley sub-scores demonstrates that external rotation is essential for good clinical functioning in reverse shoulder arthroplasty. Copyright © 2014 Elsevier Ltd. All rights reserved.
Nerve stress during reverse total shoulder arthroplasty: a cadaveric study.
Lenoir, Hubert; Dagneaux, Louis; Canovas, François; Waitzenegger, Thomas; Pham, Thuy Trang; Chammas, Michel
2017-02-01
Neurologic lesions are relatively common after total shoulder arthroplasty. These injuries are mostly due to traction. We aimed to identify the arm manipulations and steps during reverse total shoulder arthroplasty (RTSA) that affect nerve stress. Stress was measured in 10 shoulders of 5 cadavers by use of a tensiometer on each nerve from the brachial plexus, with shoulders in different arm positions and during different surgical steps of RTSA. When we studied shoulder position without prostheses, relative to the neutral position, internal rotation increased stress on the radial and axillary nerves and external rotation increased stress on the musculocutaneous, median, and ulnar nerves. Extension was correlated with increase in stress on all nerves. Abduction was correlated with increase in stress for the radial nerve. We identified 2 high-risk steps during RTSA: humeral exposition, particularly when the shoulder was in a position of more extension, and glenoid exposition. The thickness of polyethylene humeral cups used was associated with increased nerve stress in all but the ulnar nerve. During humeral preparation, the surgeon must be careful to limit shoulder extension. Care must be taken during exposure of the glenoid. Extreme rotation and oversized implants should be avoided to minimize stretch-induced neuropathies. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Polyethylene Wear in Retrieved Reverse Total Shoulder Components
Day, Judd S; MacDonald, Daniel W; Olsen, Madeline; Getz, Charles; Williams, Gerald R; Kurtz, Steven M
2011-01-01
Background Reverse total shoulder arthroplasty has been used to treat rotator cuff tear arthropathy, proximal humeral fractures and for failed conventional total shoulder prostheses. It has been suggested that polyethylene wear is potentially higher in reverse shoulder replacements than in conventional shoulder replacements. The modes and degree of polyethylene wear have not been completely elucidated. The purpose of this study was to evaluate polyethylene wear patterns in seven specimens retrieved at revision arthroplasty and identify factors that may be associated with increased wear. Methods Reverse total shoulder components were retrieved from 7 patients during revision arthroplasty for loosening and/or pain. Pre-operative glenoid tilt and placement, and scapular notching were evaluated using pre-operative radiographs. Polyethylene wear was evaluated using microCT and optical microscopy. Results Wear on the rim of the polyethylene humeral cup, was identified on all retrieved components. The extent of rim wear varied from a penetration depth of 0.1 to 4.7 mm. We could not demonstrate a correlation between scapular notching and rim wear. However, rim wear was more extensive when the inferior screw had made contact with the liner. Metal on metal wear between the humeral component and the inferior screw of one component was also observed. Wear of the intended bearing surface was minimal. Discussion Rim damage was the predominant cause of polyethylene wear in our retrieved specimens. Direct contact between the humeral component and inferior metaglene screws is concerning because this could lead to accelerated UHMWPE wear and also induce mechanical loosening of the glenoid component. PMID:21724419
Petrillo, S; Longo, U G; Papalia, R; Denaro, V
2017-08-01
To report the outcomes and complications of reverse shoulder arthroplasty (RSA) in massive irreparable rotator cuff tears (MIRCT) and cuff tear arthropathy (CTA). A systematic review of the literature contained in Medline, Cochrane, EMBASE, Google Scholar and Ovid databases was conducted on May 1, 2016, according to PRISMA guidelines. The key words "reverse total shoulder arthroplasty" or "reverse total shoulder prostheses" with "rotator cuff tears"; "failed rotator cuff surgery"; "massive rotator cuff tears"; "irreparable rotator cuff tears"; "cuff tear arthropathy"; "outcomes"; "complications" were matched. All articles reporting outcomes and complications of RSA for the management of MIRCT or CTA were included. The comparison between preoperative and postoperative clinical scores, as well as range of motion (ROM), was performed using the Wilcoxon-Mann-Whitney test. P values lower than 0.05 were considered statistically significant. Seven articles were included in our qualitative synthesis. A statistically significant improvement in all clinical scores and ROM was found comparing the preoperative value with the postoperative value. The degrees of retroversion of the humeral stem of the RSA do not influence the functional outcomes in a statistically significant fashion. There were 17.4% of complications. The most frequent was heterotopic ossification, occurring in 6.6% of patients. Revision surgery was necessary in 7.3% of patients. RSA restores pain-free ROM and improves function of the shoulder in patients with MIRCT or CTA. However, complications occur in a high percentage of patients. The lack of level I studies limits the real understanding of the potentials and limitations of RSA for the management of MIRCT and CTA.
Guery, Jacques; Favard, Luc; Sirveaux, François; Oudet, Didier; Mole, Daniel; Walch, Gilles
2006-08-01
Reverse total shoulder arthroplasty is currently being used to treat selected patients with disabling shoulder arthropathy. The purposes of this study were to investigate the medium-term results of reverse total shoulder arthroplasty and to analyze the influence of etiology on the result. We carried out a multicenter study with a minimum follow-up of five years and determined the survival rate of the prosthesis according to the initial etiology of the shoulder arthropathy. Eighty prostheses were implanted in seventy-seven patients between 1992 and 1998. Sixty-six shoulders had an arthropathy with a massive rotator cuff tear, and fourteen shoulders had a disorder with another etiology (rheumatoid arthritis, trauma, or revision arthropathy). At the time of review, eighteen patients had died and two were lost to follow-up. The remaining fifty-seven patients (sixty shoulders) were examined or interviewed by telephone at a mean follow-up of 69.6 months. Cumulative survival curves were generated with replacement of the prosthesis, glenoid loosening, and a functional Constant score of <30 as the end points. The survival rate with replacement of the prosthesis and glenoid loosening as the end points were 91% and 84%, respectively, at 120 months, with shoulders that had arthropathy with a massive rotator cuff tear demonstrating a significantly better result than those that had a disorder with another etiology (p < 0.05). On the other hand, the survival rate with an absolute Constant score of <30 as an end point was 58% at 120 months, with no significant difference with respect to etiology. Two breaks were observed in the survival curves. The first concerned survival until replacement of the prosthesis and occurred at around three years, reflecting early loosening of the prosthesis. The curve then became stable. A second break started at around six years and reflected progressive deterioration of the functional result. Our findings indicate that the reverse total prosthesis should be reserved for the treatment of very disabling shoulder arthropathy with a massive rotator cuff rupture, and it should be used exclusively in patients over seventy years old with low functional demands.
Berhouet, Julien; Kontaxis, Andreas; Gulotta, Lawrence V; Craig, Edward; Warren, Russel; Dines, Joshua; Dines, David
2015-04-01
Recent shoulder prostheses have introduced a concept of a universal humeral stem component platform that has an onlay humeral tray for the reverse total shoulder arthroplasty (RTSA). No studies have reported how humeral tray positioning can affect the biomechanics of RTSA. The Newcastle Shoulder Model was used to investigate the biomechanical effect of humeral tray positioning in the Biomet Comprehensive Total Shoulder System (Biomet, Warsaw, IN, USA) RTSA. Five humeral tray configuration positions were tested: no offset, and 5 mm offset in the anterior, posterior, medial, and lateral positions. Superior and inferior impingement were evaluated for abduction, scapular plane elevation, forward flexion, and external/internal rotation with the elbow at the side (adduction) and at 90° of shoulder abduction. Muscle lengths and moment arms (elevating and rotational) were calculated for the deltoid, the infraspinatus, the teres minor, and the subscapularis. Inferior impingement was not affected by the humeral tray position. There was less superior impingement during abduction, scapular plane elevation, and rotation with the shoulder when the tray was placed laterally or posteriorly. The subscapularis rotational moment arm was increased with a posterior offset, whereas infraspinatus and teres minor rotational moment arms were increased with an anterior offset. Very little change was observed for the deltoid elevating moment arm or for its muscle length. Positioning the humeral tray with posterior offset offers a biomechanical advantage for patients needing RTSA by decreasing superior impingement and increasing the internal rotational moment arm of the subscapularis, without creating inferior impingement. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Levy, Ofer; Narvani, Ali; Hous, Nir; Abraham, Ruben; Relwani, Jai; Pradhan, Riten; Bruguera, Juan; Sforza, Giuseppe; Atoun, Ehud
2016-08-01
Reverse shoulder prostheses are increasingly used in recent years for treatment of glenohumeral arthropathy with deficient rotator cuff. Bone preservation is becoming a major goal in shoulder replacement surgery. Metaphyseal humeral components without a stem were developed to minimize bone resection and preserve bone. This study evaluated the clinical and radiologic outcomes at 2 to 7 years using a novel short metaphyseal reverse total shoulder arthroplasty (rTSA) prosthesis without a diaphyseal stem. Between 2005 and 2010, 102 consecutive patients underwent rTSA with this implant, and 98 (20 men, 78 women) were available for follow-up. Mean age was 74.4 years (range, 38-93 years). Indications were cuff tear arthropathy, 65; fracture sequelae, 12; rheumatoid arthritis, 13; failed rotator cuff repair, 3; cuff deficiency with loosening of anatomic prosthesis, 3; and acute trauma, 2; with 17 of these as revisions. Patients' satisfaction (Subjective Shoulder Value) improved from 8 of 100 to 85 of 100. The Constant score improved from 14 to 59 (age- and sex-adjusted, 86; P < .0001). Range of motion improved from 47° to 129° in elevation, 10° to 51° in external rotation, and 21° to 65° in internal rotation. Radiographic analysis showed no lucencies, subsidence, or stress shielding around the humeral or glenoid components. Glenoid notching was found in 21 patients (18 grade 1-2; 3 grade 3). The short metaphyseal rTSA design without a diaphyseal stem shows encouraging short- to midterm results, with excellent pain relief and shoulder function, restoration of good active range of motion, and high patient satisfaction scores. The design of this implant seems to result in improved rotational movements, low incidence of glenoid notching, and no implant loosening, subsidence, or stress shielding. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Tightening force and torque of nonlocking screws in a reverse shoulder prosthesis.
Terrier, A; Kochbeck, S H; Merlini, F; Gortchacow, M; Pioletti, D P; Farron, A
2010-07-01
Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone. Copyright (c) 2010 Elsevier Ltd. All rights reserved.
Torrens, Carlos; Corrales, Monica; Gonzalez, Gemma; Solano, Alberto; Cáceres, Enrique
2008-01-01
Purpose The purpose of this study is to analyze the morphology of the scapula with reference to the glenoid component implantation in reversed shoulder prosthesis, in order to improve primary fixation of the component. Methods Seventy-three 3-dimensional computed tomography of the scapula and 108 scapular dry specimens were analyzed to determine the anterior and posterior length of the glenoid neck, the angle between the glenoid surface and the upper posterior column of the scapula and the angle between the major craneo-caudal glenoid axis and the base of the coracoid process and the upper posterior column. Results The anterior and posterior length of glenoid neck was classified into two groups named "short-neck" and "long-neck" with significant differences between them. The angle between the glenoid surface and the upper posterior column of the scapula was also classified into two different types: type I (mean 50°–52°) and type II (mean 62,50°–64°), with significant differences between them (p < 0,001). The angle between the major craneo-caudal glenoid axis and the base of the coracoid process averaged 18,25° while the angle with the upper posterior column of the scapula averaged 8°. Conclusion Scapular morphological variability advices for individual adjustments of glenoid component implantation in reversed total shoulder prosthesis. Three-dimensional computed tomography of the scapula constitutes an important tool when planning reversed prostheses implantation. PMID:18847487
Torrens, Carlos; Corrales, Monica; Gonzalez, Gemma; Solano, Alberto; Cáceres, Enrique
2008-10-10
The purpose of this study is to analyze the morphology of the scapula with reference to the glenoid component implantation in reversed shoulder prosthesis, in order to improve primary fixation of the component. Seventy-three 3-dimensional computed tomography of the scapula and 108 scapular dry specimens were analyzed to determine the anterior and posterior length of the glenoid neck, the angle between the glenoid surface and the upper posterior column of the scapula and the angle between the major craneo-caudal glenoid axis and the base of the coracoid process and the upper posterior column. The anterior and posterior length of glenoid neck was classified into two groups named "short-neck" and "long-neck" with significant differences between them. The angle between the glenoid surface and the upper posterior column of the scapula was also classified into two different types: type I (mean 50 degrees-52 degrees ) and type II (mean 62.50 degrees-64 degrees ), with significant differences between them (p < 0.001). The angle between the major craneo-caudal glenoid axis and the base of the coracoid process averaged 18,25 degrees while the angle with the upper posterior column of the scapula averaged 8 degrees . Scapular morphological variability advices for individual adjustments of glenoid component implantation in reversed total shoulder prosthesis. Three-dimensional computed tomography of the scapula constitutes an important tool when planning reversed prostheses implantation.
Effect of lateralized design on muscle and joint reaction forces for reverse shoulder arthroplasty.
Liou, William; Yang, Yang; Petersen-Fitts, Graysen R; Lombardo, Daniel J; Stine, Sasha; Sabesan, Vani J
2017-04-01
Manufacturers of reverse shoulder arthroplasty (RSA) implants have recently designed innovative implants to optimize performance in rotator cuff-deficient shoulders. These advancements are not without tradeoffs and can have negative biomechanical effects. The objective of this study was to develop an integrated finite element analysis-kinematic model to compare the muscle forces and joint reaction forces (JRFs) of 3 different RSA designs. A kinematic model of a normal shoulder joint was adapted from the Delft model and integrated with the well-validated OpenSim shoulder model. Static optimizations then allowed for calculation of the individual muscle forces, moment arms, and JRFs relative to net joint moments. Three-dimensional computer models of 3 RSA designs-humeral lateralized design (HLD), glenoid lateralized design, and Grammont design-were integrated, and parametric studies were performed. Overall, there were decreases in deltoid and rotator cuff muscle forces for all 3 RSA designs. These decreases were greatest in the middle deltoid of the HLD model for abduction and flexion and in the rotator cuff muscles under both internal rotation and external rotation. The JRFs in abduction and flexion decreased similarly for all RSA designs compared with the normal shoulder model, with the greatest decrease seen in the HLD model. These findings demonstrate that the design characteristics implicit in these modified RSA prostheses result in mechanical differences most prominently seen in the deltoid muscle and overall JRFs. Further research using this novel integrated model can help guide continued optimization of RSA design and clinical outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Costantini, Oren; Choi, Daniel S; Kontaxis, Andreas; Gulotta, Lawrence V
2015-07-01
There has been a renewed interest in lateralizing the center of rotation (CoR) in implants used in reverse shoulder arthroplasty. The aim of this study was to determine the sensitivity of lateralization of the CoR on the glenohumeral joint contact forces, muscle moment arms, torque across the bone-implant interface, and the stability of the implant. A 3-dimensional virtual model was used to investigate how lateralization affects deltoid muscle moment arm and glenohumeral joint contact forces. This model was virtually implanted with 5 progressively lateralized reverse shoulder prostheses. The joint contact loads and deltoid moment arms were calculated for each lateralization over the course of 3 simulated standard humerothoracic motions. Lateralization of the CoR leads to an increase in the overall joint contact forces across the glenosphere. Most of this increased loading occurred through compression, although increases in anterior/posterior and superior/inferior shear were also observed. Moment arms of the deltoid consistently decreased with lateralization. Bending moments at the implant interface increased with lateralization. Progressive lateralization resulted in improved stability ratios. Lateralization results in increased joint loading. Most of that loading occurs through compression, although there were also increases in shear forces. Anterior/posterior shear is currently not accounted for in implant fixation studies, leaving its effect on implant fixation unknown. Future studies should incorporate shear forces into their models to more accurately assess fixation methods. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Bayona, Carlos Eduardo Afanador; Somerson, Jeremy S; Matsen, Frederick A
2018-02-01
National registries are valuable tools for understanding the results of shoulder arthroplasty across populations. These databases provide an unselected view of shoulder joint replacement within geographical areas that cannot be obtained from case series or prospective studies. They can be particularly helpful in determining which diagnoses, patients, procedures, and prostheses have higher than expected rates of revision. In an attempt to determine the generalizability of registry data, we asked, 'how similar are the patients and procedures among the different national registries?' We analyzed national shoulder arthroplasty registries and databases accessed via Internet portals and through a PubMed literature search. Seven national/regional registries and five publications regarding national shoulder arthroplasty data were identified; these sources contained a combined total of 261,484 shoulder arthroplasty cases. The percentages of hemiarthroplasty, anatomic (aTSA) and reverse total shoulders (rTSA), the diagnoses leading to arthroplasty, the mean patient age, and the distribution of patient gender varied significantly among these different databases. This study indicates that the indications for and application of shoulder arthroplasty have important geographical variations and that these variations must be considered when comparing outcomes of shoulder arthroplasty from different locations. Without controlling for age, gender, diagnosis and procedure type, the results from one national registry may not be applicable to patients from a different location. In that national data provide the opportunity to reduce costs by identifying implants and procedures with higher failure rates, the funding of registries needs to be free of conflicts of interest.
Merolla, Giovanni; Walch, Gilles; Ascione, Francesco; Paladini, Paolo; Fabbri, Elisabetta; Padolino, Antonio; Porcellini, Giuseppe
2018-04-01
There are few investigations comparing lateralized and medialized reverse total shoulder arthroplasty (RTSA) in patients with cuff tear arthropathy. This study assessed the outcomes of 2 RTSA designs. Sixty-eight consecutive cuff tear arthropathy patients (74 shoulders) with a follow-up of at least 24 months received a Grammont or an onlay curved short-stem humeral component, with or without glenoid lateralization; a cementless humeral stem was implanted in >90%. Clinical outcome measures included active range of motion (anterior and lateral elevation, external and internal rotation), pain, and the Constant-Murley score. Radiologic outcomes included radiolucency, condensation lines, cortical thinning, spot weld, loosening and subsidence, and tuberosity resorption for the humeral component and radiolucency, scapular notching, formation of scapular bone spurs, ossifications, and loosening for the glenoid component. Both prostheses provided significant differences between preoperative and postoperative scores and showed a similar complication rate. Scapular fractures were found only in the patients who received the curved short-stem implant. Glenoid bone grafting did not significantly affect clinical scores. Both implants provided similar postoperative shoulder mobility, even though the lateralized curved stem was associated with higher delta scores for external rotation (P = .002) and lower rates of scapular notching (P = .0003), glenoid radiolucency (P = .016), and humeral bone remodeling (P = .004 and P = .030 for cortical thinning and spot weld, respectively). Medialized and short-stem lateralized RTSA implants provided similar midterm clinical outcomes and range of motion. The curved short stem was associated with higher delta scores for external rotation and a lower rate of radiographic risk factors. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Computer-aided dental prostheses construction using reverse engineering.
Solaberrieta, E; Minguez, R; Barrenetxea, L; Sierra, E; Etxaniz, O
2014-01-01
The implementation of computer-aided design/computer-aided manufacturing (CAD/CAM) systems with virtual articulators, which take into account the kinematics, constitutes a breakthrough in the construction of customised dental prostheses. This paper presents a multidisciplinary protocol involving CAM techniques to produce dental prostheses. This protocol includes a step-by-step procedure using innovative reverse engineering technologies to transform completely virtual design processes into customised prostheses. A special emphasis is placed on a novel method that permits a virtual location of the models. The complete workflow includes the optical scanning of the patient, the use of reverse engineering software and, if necessary, the use of rapid prototyping to produce CAD temporary prostheses.
Targeted Muscle Reinnervation for Transradial Amputation: Description of Operative Technique.
Morgan, Emily N; Kyle Potter, Benjamin; Souza, Jason M; Tintle, Scott M; Nanos, George P
2016-12-01
Targeted muscle reinnervation (TMR) is a revolutionary surgical technique that, together with advances in upper extremity prostheses and advanced neuromuscular pattern recognition, allows intuitive and coordinated control in multiple planes of motion for shoulder disarticulation and transhumeral amputees. TMR also may provide improvement in neuroma-related pain and may represent an opportunity for sensory reinnervation as advances in prostheses and haptic feedback progress. Although most commonly utilized following shoulder disarticulation and transhumeral amputations, TMR techniques also represent an exciting opportunity for improvement in integrated prosthesis control and neuroma-related pain improvement in patients with transradial amputations. As there are no detailed descriptions of this technique in the literature to date, we provide our surgical technique for TMR in transradial amputations.
Stemless shoulder arthroplasty: a literature review
PETRICCIOLI, DARIO; BERTONE, CELESTE; MARCHI, GIACOMO
2015-01-01
The design of humeral implants for shoulder arthroplasty has evolved over the years. The new-generation modular shoulder prostheses have an anatomical humeral stem that replicates the three-dimensional parameters of the proximal humerus. An anatomical reconstruction is the best way to restore stability and mobility of the prosthetic shoulder and improve implant durability. However, a perfect anatomical match is not always possible in, for example, patients with post-traumatic osteoarthritis of the shoulder and deformities in the metaphyseal region. To avoid stem-related complications while retaining the advantages of the fourth generation of shoulder implants, different stemless implants have been developed. The stemless shoulder prosthesis is a new concept in shoulder arthroplasty. The authors review the indications, surgical technique, clinical and radiological midterm results, and complications of these humeral implants. PMID:26151038
A history of reverse total shoulder arthroplasty.
Flatow, Evan L; Harrison, Alicia K
2011-09-01
Management of the cuff-deficient arthritic shoulder has long been challenging. Early unconstrained shoulder arthroplasty systems were associated with high complication and implant failure rates. The evolution toward the modern reverse shoulder arthroplasty includes many variables of constrained shoulder arthroplasty designs. This review explores the development of reverse shoulder arthroplasty, specifically describing (1) the evolution of reverse shoulder arthroplasty designs, (2) the biomechanical variations in the evolution of this arthroplasty, and (3) the current issues relevant to reverse shoulder arthroplasty today. Using a PubMed search, the literature was explored for articles addressing reverse shoulder arthroplasty, focusing on those papers with historical context. Results of the early designs were apparently poor, although they were not subjected to rigorous clinical research and usually reported only in secondary literature. We identified a trend of glenoid component failure in the early reverse designs. This trend was recognized and reported by authors as the reverse shoulder evolved. Authors reported greater pain relief and better function in reverse shoulder arthroplasty with the fundamental change of Grammont's design (moving the center of rotation medially and distally). However, current reports suggest lingering concerns and challenges with today's designs. The history of reverse shoulder arthroplasty involves the designs of many forward-thinking surgeons. Many of these highly constrained systems failed, although more recent designs have demonstrated improved longevity and implant performance. Reverse shoulder arthroplasty requires ongoing study, with challenges and controversies remaining around present-day designs.
How reverse shoulder arthroplasty works.
Walker, Matthew; Brooks, Jordan; Willis, Matthew; Frankle, Mark
2011-09-01
The reverse total shoulder arthroplasty was introduced to treat the rotator cuff-deficient shoulder. Since its introduction, an improved understanding of the biomechanics of rotator cuff deficiency and reverse shoulder arthroplasty has facilitated the development of modern reverse arthroplasty designs. We review (1) the basic biomechanical challenges associated with the rotator cuff-deficient shoulder; (2) the biomechanical rationale for newer reverse shoulder arthroplasty designs; (3) the current scientific evidence related to the function and performance of reverse shoulder arthroplasty; and (4) specific technical aspects of reverse shoulder arthroplasty. A PubMed search of the English language literature was conducted using the key words reverse shoulder arthroplasty, rotator cuff arthropathy, and biomechanics of reverse shoulder arthroplasty. Articles were excluded if the content fell outside of the biomechanics of these topics, leaving the 66 articles included in this review. Various implant design factors as well as various surgical implantation techniques affect stability of reverse shoulder arthroplasty and patient function. To understand the implications of individual design factors, one must understand the function of the normal and the cuff-deficient shoulder and coalesce this understanding with the pathology presented by each patient to choose the proper surgical technique for reconstruction. Several basic science and clinical studies improve our understanding of various design factors in reverse shoulder arthroplasty. However, much work remains to further elucidate the performance of newer designs and to evaluate patient outcomes using validated instruments such as the American Society for Elbow Surgery, simple shoulder test, and the Constant-Murley scores.
Prevalence of neurologic lesions after total shoulder arthroplasty.
Lädermann, A; Lübbeke, A; Mélis, B; Stern, R; Christofilopoulos, P; Bacle, G; Walch, G
2011-07-20
Clinically evident neurologic injury of the involved limb after total shoulder arthroplasty is not uncommon, but the subclinical prevalence is unknown. The purposes of this prospective study were to determine the subclinical prevalence of neurologic lesions after reverse shoulder arthroplasty and anatomic shoulder arthroplasty, and to evaluate the correlation of neurologic injury to postoperative lengthening of the arm. All patients undergoing either a reverse or an anatomic shoulder arthroplasty were included during the period studied. This study focused on the clinical, radiographic, and preoperative and postoperative electromyographic evaluation, with measurement of arm lengthening in patients who had reverse shoulder arthroplasty according to a previously validated protocol. Between November 2007 and February 2009, forty-one patients (forty-two shoulders) underwent reverse shoulder arthroplasty (nineteen shoulders) or anatomic primary shoulder arthroplasty (twenty-three shoulders). The two groups were similar with respect to sex distribution, preoperative neurologic lesions, and Constant score. Electromyography performed at a mean of 3.6 weeks postoperatively in the reverse shoulder arthroplasty group showed subclinical electromyographic changes in nine shoulders, involving mainly the axillary nerve; eight resolved in less than six months. In the anatomic shoulder arthroplasty group, a brachial plexus lesion was evident in one shoulder. The prevalence of acute postoperative nerve injury was significantly more frequent in the reverse shoulder arthroplasty group (p = 0.002), with a 10.9 times higher risk (95% confidence interval, 1.5 to 78.5). Mean lengthening (and standard deviation) of the arm after reverse shoulder arthroplasty was 2.7 ± 1.8 cm (range, 0 to 5.9 cm) compared with the normal, contralateral side. The occurrence of peripheral neurologic lesions following reverse shoulder arthroplasty is relatively common, but usually transient. Arm lengthening with a reverse shoulder arthroplasty may be responsible for these nerve injuries.
Rosenberg, Nahum; Neumann, Lars; Modi, Amit; Mersich, Istvan J; Wallace, Angus W
2007-01-01
Background The uncemented Nottingham Total Shoulder Replacement prosthesis system (Nottingham TSR) was developed from the previous BioModular® shoulder prosthesis taking into consideration the causes of the initial implant's failure. We investigated the impact of changes in the design of Nottingham TSR prosthesis on its survivorship rate. Methods Survivorship analyses of three types of uncemented total shoulder arthroplasty prostheses (BioModular®, initial Nottingham TSR and current Nottingham TSR systems with 11, 8 and 4 year survivorship data respectively) were compared. All these prostheses were implanted for the treatment of disabling pain in the shoulder due to primary and secondary osteoarthritis or rheumatoid arthritis. Each type of the prosthesis studied was implanted in consecutive group of patients – 90 patients with BioModular® system, 103 with the initial Nottingham TSR and 34 patients with the current Nottingham TSR system. The comparison of the annual cumulative survivorship values in the compatible time range between the three groups was done according to the paired t test. Results The 8-year and 11-year survivorship rates for the initially used modified BioModular® uncemented prosthesis were relatively low (75.6% and 71.7% respectively) comparing to the reported survivorship of the conventional cemented implants. The 8-year survivorship for the uncemented Nottingham TSR prosthesis was significantly higher (81.8%), but still not in the desired range of above 90%, that is found in other cemented designs. Glenoid component loosening was the main factor of prosthesis failure in both prostheses and mainly occurred in the first 4 postoperative years. The 4-year survivorship of the currently re-designed Nottingham TSR prosthesis, with hydroxylapatite coating of the glenoid baseplate, was significantly higher, 93.1% as compared to 85.1% of the previous Nottingham TSR. Conclusion The initial Nottingham shoulder prosthesis showed significantly higher survivorship than the BioModular® uncemented prosthesis, but lower than expected. Subsequently re-designed Nottingham TSR system presented a high short term survivorship rate that encourages its ongoing use PMID:17683577
Mattei, Lorenza; Di Puccio, Francesca; Joyce, Thomas J; Ciulli, Enrico
2015-03-01
In the present study, numerical and experimental wear investigations on reverse total shoulder arthroplasties (RTSAs) were combined in order to estimate specific wear coefficients, currently not available in the literature. A wear model previously developed by the authors for metal-on-plastic hip implants was adapted to RTSAs and applied in a double direction: firstly, to evaluate specific wear coefficients for RTSAs from experimental results and secondly, to predict wear distribution. In both cases, the Archard wear law (AR) and the wear law of UHMWPE (PE) were considered, assuming four different k functions. The results indicated that both the wear laws predict higher wear coefficients for RTSA with respect to hip implants, particularly the AR law, with k values higher than twofold the hip ones. Such differences can significantly affect predictive wear model results for RTSA, when non-specific wear coefficients are used. Moreover, the wear maps simulated with the two laws are markedly different, although providing the same wear volume. A higher wear depth (+51%) is obtained with the AR law, located at the dome of the cup, while with the PE law the most worn region is close to the edge. Taking advantage of the linear trend of experimental volume losses, the wear coefficients obtained with the AR law should be valid despite having neglected the geometry update in the model. Copyright © 2015 Elsevier Ltd. All rights reserved.
Kaliki, Rahul R; Davoodi, Rahman; Loeb, Gerald E
2013-03-01
C5/C6 tetraplegic patients and transhumeral amputees may be able to use voluntary shoulder motion as command signals for a functional electrical stimulation system or transhumeral prosthesis. Stereotyped relationships, termed "postural synergies," among the shoulder, forearm, and wrist joints emerge during goal-oriented reaching and transport movements as performed by able-bodied subjects. Thus, the posture of the shoulder can potentially be used to infer the desired posture of the elbow and forearm joints during reaching and transporting movements. We investigated how well able-bodied subjects could learn to use a noninvasive command scheme based on inferences from these postural synergies to control a simulated transhumeral prosthesis in a virtual reality task. We compared the performance of subjects using the inferential command scheme (ICS) with subjects operating the simulated prosthesis in virtual reality according to complete motion tracking of their actual arm and hand movements. Initially, subjects performed poorly with the ICS but improved rapidly with modest amounts of practice, eventually achieving performance only slightly less than subjects using complete motion tracking. Thus, inferring the desired movement of distal joints from voluntary shoulder movements appears to be an intuitive and noninvasive approach for obtaining command signals for prostheses to restore reaching and grasping functions.
Hernandez, Nicholas M; Chalmers, Brian P; Wagner, Eric R; Sperling, John W; Cofield, Robert H; Sanchez-Sotelo, Joaquin
2017-11-01
Instability after shoulder arthroplasty remains a complication with limited salvage options. Reoperation for instability with anatomic designs has led to high rates of persistent instability, therefore we aimed to evaluate the use of RSA for treatment of prosthetic instability. (1) After revision shoulder arthroplasty to a reverse prosthesis (RSA), what is the survivorship free from dislocations at 2 and 5 years? (2) What factors are associated with dislocations? (3) What is the survivorship free from revision after revision to RSA? (4) From preoperation to postrevision to RSA, what are the clinical outcomes-the proportion of patients with moderate to severe pain, shoulder elevation and external rotation ROM, American Shoulder and Elbow Surgeons scores, and Simple Shoulder Test scores? All shoulder arthroplasties revised for prosthetic instability using RSA components between January 2004 and July 2014 were retrospectively studied. During the period in question, we performed 82 revisions for instability of an anatomic total shoulder arthroplasty (TSA) (n = 62), hemiarthroplasty (n = 13), or reverse TSA (n = 7). We typically used a reverse TSA to treat this problem, but we identified 12 treated in other ways, including revision of a TSA to hemiarthroplasty (n = 3), revision of a reverse TSA to hemiarthroplasty (n = 2), revision of hemiarthroplasty to a hemiarthroplasty (n = 1), and revision of an anatomic TSA to another anatomic TSA (n = 6). This left 70 patients for evaluation; of those, 65 (93%) were available for analysis at a mean of 3 years (range, 2-10 years). A total of seven patients died. Eight of the 65 shoulders were not evaluated during the last 5 years, including three in patients who died earlier. The mean age of the patients at the time of revision RSA was 65 years (range, 40-89 years). Data were obtained from a longitudinally maintained institutional joint registry. Instability was defined as severe subluxation confirmed on clinical and radiographic examinations. We evaluated pain and ROM, and Kaplan-Meier curves were used to estimate survivorship. The survivorship free from dislocation at 2 and 5 years was 87% (95% CI, 80%-94%) and 79% (95% CI, 67%-91%) respectively, with 10 of 65 (15%) patients having an episode of dislocation after revision surgery. Persistent instability was more common in those with a BMI greater than 35 kg/m 2 (hazard ratio [HR], 5; 95% CI, 2-16; p = 0.008) and prior hemiarthroplasty (HR, 5; 95% CI, 2-16; p = 0.005), whereas patients who had undergone a previous TSA were less likely to have persistent instability (HR, 0.08; 95% CI, 0.0-0.30; p < 0.001) The survival free from rerevision for any indication at 2 and 5 years was 85% (95% CI, 76%-94%) and 78% (95% CI, 66%-90%) respectively; with the numbers available, we were not able to find associated factors. Fewer patients had moderate or severe pain after revision to RSA (preoperative: 48 of 65 [74%]; postoperative: nine of 65 [14%]; p < 0.001). After surgery, patients showed improvement in shoulder elevation (preoperative: 42° [± 30°], postoperative: 112° [42°]; mean difference, 70° [95% CI, - 83 o to 57°]; p < 0.001) and external rotation (preoperative: 20° [± 22°], postoperative: 42° [± 23°]; mean difference, 22° [95% CI, - 30° to - 14°]; p < 0.001). American Shoulder and Elbow Surgeons scores improved (preoperative: 21 [± 10], postoperative: 68 [± 14], mean difference, 46 [95% CI, - 58 to - 35]; p < 0.001); where a higher score is better. Simple Shoulder Test scores also improved (preoperative: 2/12 [± 2], postoperative: 7/12 [± 3]; mean difference, 5 [95% CI, - 7 to - 2.17]; p < 0.001); where a higher score is better. Revision RSA for prosthetic instability after shoulder arthroplasty is associated with reasonable implant survival and few complications. Approximately one in seven patients will have a recurrent dislocation. In patients with persistent instability or with risk factors for instability, consideration should be given for use of larger glenospheres and increasing the lateral offset at the time of RSA. Level IV, therapeutic study.
Computational reverse shoulder prosthesis model: Experimental data and verification.
Martins, A; Quental, C; Folgado, J; Ambrósio, J; Monteiro, J; Sarmento, M
2015-09-18
The reverse shoulder prosthesis aims to restore the stability and function of pathological shoulders, but the biomechanical aspects of the geometrical changes induced by the implant are yet to be fully understood. Considering a large-scale musculoskeletal model of the upper limb, the aim of this study is to evaluate how the Delta reverse shoulder prosthesis influences the biomechanical behavior of the shoulder joint. In this study, the kinematic data of an unloaded abduction in the frontal plane and an unloaded forward flexion in the sagittal plane were experimentally acquired through video-imaging for a control group, composed of 10 healthy shoulders, and a reverse shoulder group, composed of 3 reverse shoulders. Synchronously, the EMG data of 7 superficial muscles were also collected. The muscle force sharing problem was solved through the minimization of the metabolic energy consumption. The evaluation of the shoulder kinematics shows an increase in the lateral rotation of the scapula in the reverse shoulder group, and an increase in the contribution of the scapulothoracic joint to the shoulder joint. Regarding the muscle force sharing problem, the musculoskeletal model estimates an increased activity of the deltoid, teres minor, clavicular fibers of the pectoralis major, and coracobrachialis muscles in the reverse shoulder group. The comparison between the muscle forces predicted and the EMG data acquired revealed a good correlation, which provides further confidence in the model. Overall, the shoulder joint reaction force was lower in the reverse shoulder group than in the control group. Copyright © 2015 Elsevier Ltd. All rights reserved.
Estimation of distal arm joint angles from EMG and shoulder orientation for transhumeral prostheses.
Akhtar, Aadeel; Aghasadeghi, Navid; Hargrove, Levi; Bretl, Timothy
2017-08-01
In this paper, we quantify the extent to which shoulder orientation, upper-arm electromyography (EMG), and forearm EMG are predictors of distal arm joint angles during reaching in eight subjects without disability as well as three subjects with a unilateral transhumeral amputation and targeted reinnervation. Prior studies have shown that shoulder orientation and upper-arm EMG, taken separately, are predictors of both elbow flexion/extension and forearm pronation/supination. We show that, for eight subjects without disability, shoulder orientation and upper-arm EMG together are a significantly better predictor of both elbow flexion/extension during unilateral (R 2 =0.72) and mirrored bilateral (R 2 =0.72) reaches and of forearm pronation/supination during unilateral (R 2 =0.77) and mirrored bilateral (R 2 =0.70) reaches. We also show that adding forearm EMG further improves the prediction of forearm pronation/supination during unilateral (R 2 =0.82) and mirrored bilateral (R 2 =0.75) reaches. In principle, these results provide the basis for choosing inputs for control of transhumeral prostheses, both by subjects with targeted motor reinnervation (when forearm EMG is available) and by subjects without target motor reinnervation (when forearm EMG is not available). In particular, we confirm that shoulder orientation and upper-arm EMG together best predict elbow flexion/extension (R 2 =0.72) for three subjects with unilateral transhumeral amputations and targeted motor reinnervation. However, shoulder orientation alone best predicts forearm pronation/supination (R 2 =0.88) for these subjects, a contradictory result that merits further study. Copyright © 2017 Elsevier Ltd. All rights reserved.
Uncommon Indications for Reverse Total Shoulder Arthroplasty
Hyun, Yoon Suk; Huri, Gazi; Garbis, Nickolas G.
2013-01-01
Total shoulder arthroplasty and shoulder hemiarthroplasty have been the traditional method for treating a variety of shoulder conditions, including arthritis, cuff tear arthropathy, and some fracture types. However, these procedures did not provide consistently good results for patients with torn rotator cuffs. The development of the reverse prosthesis by Grammont in the late 20th century revolutionized the treatment of the rotator-cuff-deficient shoulder with arthritis. The main indication for the reverse prosthesis remains the patient with cuff tear arthropathy who has pain and loss of motion. Because the reverse total shoulder arthroplasty produced such good results in these patients, the indications for the reverse prosthesis have expanded to include other shoulder conditions that have previously been difficult to treat successfully and predictably. This review discusses and critically reviews these newer indications for the reverse total shoulder arthroplasty. PMID:24340143
The Contribution of Reverse Shoulder Arthroplasty to Utilization of Primary Shoulder Arthroplasty
Jain, Nitin B.; Yamaguchi, Ken
2014-01-01
Background We assessed the contribution of reverse shoulder arthroplasty to overall utilization of primary shoulder arthroplasty, and present age and sex stratified national rates of shoulder arthroplasty. We also assessed contemporary complication rates, mortality, and indications for shoulder arthroplasty, as well as estimates and indications for revision arthroplasty. Methods We used the Nationwide Inpatient Samples for 2009–2011 to calculate estimates of shoulder arthroplasty and assessed trends using joinpoint regression. Results The cumulative estimated utilization of primary shoulder arthroplasty (total anatomical, hemi, and reverse) increased significantly from 52,397 procedures (95% CI=47,093–57,701) in 2009 to 67,184 cases (95% CI=60,638–73,731) in 2011. Reverse shoulder arthroplasty accounted for 42% of all primary shoulder arthroplasty procedures in 2011. The diagnosis of concomitant diagnosis of osteoarthritis and rotator cuff impairment was found in only 29.8% of reverse shoulder arthroplasty cases. The highest rate of reverse shoulder arthroplasty was in the 75–84 year female sub-group (77; 95% CI=67–87). Revision cases were 8.8% and 8.2% of all shoulder arthroplasties in 2009 and 2011, respectively, and 35% of revision cases were secondary to mechanical complications/loosening while 18% were due to dislocation. Conclusions The utilization of primary shoulder arthroplasty significantly increased in just a three year time span, with a major contribution from reverse shoulder arthroplasty in 2011. Indications appear to have expanded as a large percentage of patients did not have rotator cuff pathology. The burden from revision arthroplasties was also substantial and efforts to optimize outcomes and longevity of primary shoulder arthroplasty are needed. Level of evidence Epidemiology Study, Database Analysis PMID:25304043
Sekine, Masashi; Kita, Kahori; Yu, Wenwei
2015-01-01
Unlike forearm amputees, transhumeral amputees have residual stumps that are too small to provide a sufficient range of operation for their prosthetic parts to perform usual activities of daily living. Furthermore, it is difficult for small residual stumps to provide sufficient impact absorption for safe manipulation in daily living, as intact arms do. Therefore, substitution of upper limb function in transhumeral amputees requires a sufficient range of motion and sufficient viscoelasticity for shoulder prostheses under critical weight and dimension constraints. We propose the use of two different types of actuators, ie, pneumatic elastic actuators (PEAs) and servo motors. PEAs offer high power-to-weight performance and have intrinsic viscoelasticity in comparison with motors or standard industrial pneumatic cylinder actuators. However, the usefulness of PEAs in large working spaces is limited because of their short strokes. Servo motors, in contrast, can be used to achieve large ranges of motion. In this study, the relationship between the force and stroke of PEAs was investigated. The impact absorption of both types of actuators was measured using a single degree-of-freedom prototype to evaluate actuator compliance for safety purposes. Based on the fundamental properties of the actuators identified, a four degree-of-freedom robotic arm is proposed for prosthetic use. The configuration of the actuators and functional parts was designed to achieve a specified range of motion and torque calculated from the results of a simulation of typical movements performed in usual activities of daily living. Our experimental results showed that the requirements for the shoulder prostheses could be satisfied.
Effect of reverse shoulder design philosophy on muscle moment arms.
Hamilton, Matthew A; Diep, Phong; Roche, Chris; Flurin, Pierre Henri; Wright, Thomas W; Zuckerman, Joseph D; Routman, Howard
2015-04-01
This study analyzes the muscle moment arms of three different reverse shoulder design philosophies using a previously published method. Digital bone models of the shoulder were imported into a 3D modeling software and markers placed for the origin and insertion of relevant muscles. The anatomic model was used as a baseline for moment arm calculations. Subsequently, three different reverse shoulder designs were virtually implanted and moment arms were analyzed in abduction and external rotation. The results indicate that the lateral offset between the joint center and the axis of the humerus specific to one reverse shoulder design increased the external rotation moment arms of the posterior deltoid relative to the other reverse shoulder designs. The other muscles analyzed demonstrated differences in the moment arms, but none of the differences reached statistical significance. This study demonstrated how the combination of variables making up different reverse shoulder designs can affect the moment arms of the muscles in different and statistically significant ways. The role of humeral offset in reverse shoulder design has not been previously reported and could have an impact on external rotation and stability achieved post-operatively. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Multibody system of the upper limb including a reverse shoulder prosthesis.
Quental, C; Folgado, J; Ambrósio, J; Monteiro, J
2013-11-01
The reverse shoulder replacement, recommended for the treatment of several shoulder pathologies such as cuff tear arthropathy and fractures in elderly people, changes the biomechanics of the shoulder when compared to the normal anatomy. Although several musculoskeletal models of the upper limb have been presented to study the shoulder joint, only a few of them focus on the biomechanics of the reverse shoulder. This work presents a biomechanical model of the upper limb, including a reverse shoulder prosthesis, to evaluate the impact of the variation of the joint geometry and position on the biomechanical function of the shoulder. The biomechanical model of the reverse shoulder is based on a musculoskeletal model of the upper limb, which is modified to account for the properties of the DELTA® reverse prosthesis. Considering two biomechanical models, which simulate the anatomical and reverse shoulder joints, the changes in muscle lengths, muscle moment arms, and muscle and joint reaction forces are evaluated. The muscle force sharing problem is solved for motions of unloaded abduction in the coronal plane and unloaded anterior flexion in the sagittal plane, acquired using video-imaging, through the minimization of an objective function related to muscle metabolic energy consumption. After the replacement of the shoulder joint, significant changes in the length of the pectoralis major, latissimus dorsi, deltoid, teres major, teres minor, coracobrachialis, and biceps brachii muscles are observed for a reference position considered for the upper limb. The shortening of the teres major and teres minor is the most critical since they become unable to produce active force in this position. Substantial changes of muscle moment arms are also observed, which are consistent with the literature. As expected, there is a significant increase of the deltoid moment arms and more fibers are able to elevate the arm. The solutions to the muscle force sharing problem support the biomechanical advantages attributed to the reverse shoulder design and show an increase in activity from the deltoid, teres minor, and coracobrachialis muscles. The glenohumeral joint reaction forces estimated for the reverse shoulder are up to 15% lower than those in the normal shoulder anatomy. The data presented here complements previous publications, which, all together, allow researchers to build a biomechanical model of the upper limb including a reverse shoulder prosthesis.
The anterior deltoid's importance in reverse shoulder arthroplasty: a cadaveric biomechanical study.
Schwartz, Daniel G; Kang, Sang Hoon; Lynch, T Sean; Edwards, Sara; Nuber, Gordon; Zhang, Li-Qun; Saltzman, Matthew
2013-03-01
Frequently, patients who are candidates for reverse shoulder arthroplasty have had prior surgery that may compromise the anterior deltoid muscle. There have been conflicting reports on the necessity of the anterior deltoid thus it is unclear whether a dysfunctional anterior deltoid muscle is a contraindication to reverse shoulder arthroplasty. The purpose of this study was to determine the 3-dimensional (3D) moment arms for all 6 deltoid segments, and determine the biomechanical significance of the anterior deltoid before and after reverse shoulder arthroplasty. Eight cadaveric shoulders were evaluated with a 6-axis force/torque sensor to assess the direction of rotation and 3D moment arms for all 6 segments of the deltoid both before and after placement of a reverse shoulder prosthesis. The 2 segments of anterior deltoid were unloaded sequentially to determine their functional role. The 3D moment arms of the deltoid were significantly altered by placement of the reverse shoulder prosthesis. The anterior and middle deltoid abduction moment arms significantly increased after placement of the reverse prosthesis (P < .05). Furthermore, the loss of the anterior deltoid resulted in a significant decrease in both abduction and flexion moments (P < .05). The anterior deltoid is important biomechanically for balanced function after a reverse total shoulder arthroplasty. Losing 1 segment of the anterior deltoid may still allow abduction; however, losing both segments of the anterior deltoid may disrupt balanced abduction. Surgeons should be cautious about performing reverse shoulder arthroplasty in patients who do not have a functioning anterior deltoid muscle. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Willing, Ryan; Lapner, Michael; King, Graham J W; Johnson, James A
2014-11-01
Distal humeral hemiarthroplasty alters cartilage contact mechanics, which may predispose to osteoarthritis. Current prostheses do not replicate the native anatomy, and therefore contribute to these changes. We hypothesized that prostheses reverse-engineered from the native bone shape would provide similar contact patterns as the native articulation. Reverse-engineered hemiarthroplasty prostheses were manufactured for five cadaveric elbows based on CT images of the distal humerus. Passive flexion trials with constant muscle forces were performed with the native articulation intact while bone motions were recorded using a motion tracking system. Motion trials were then repeated after the distal humerus was replaced with a corresponding reverse-engineered prosthesis. Contact areas and patterns were reconstructed using computer models created from CT scan images combined with the motion tracker data. The total contact areas, as well as the contact area within smaller sub-regions of the ulna and radius, were analyzed for changes resulting from hemiarthroplasty using repeated-measures ANOVAs. Contact area at the ulna and radius decreased on average 42% (SD 19%, P=.008) and 41% (SD 42%, P=.096), respectively. Contact area decreases were not uniform throughout the different sub-regions, suggesting that contact patterns were also altered. Reverse-engineered prostheses did not reproduce the same contact pattern as the native joints, possibly because the thickness of the distal humerus cartilage layer was neglected when generating the prosthesis shapes or as a consequence of the increased stiffness of the metallic implants. Alternative design strategies and materials for hemiarthroplasty should be considered in future work. Copyright © 2014 Elsevier Ltd. All rights reserved.
Biomechanics of Reverse Shoulder Arthroplasty: Current Concepts.
Lorenzetti, Adam J; Stone, Geoffrey P; Simon, Peter; Frankle, Mark A
2016-01-01
The evolution of reverse shoulder arthroplasty has provided surgeons with new solutions for many complex shoulder problems. A primary goal of orthopaedics is the restoration or re-creation of functional anatomy to reduce pain and improve function, which can be accomplished by either repairing injured structures or replacing them as anatomically as possible. If reconstructible tissue is lacking or not available, which is seen in patients who have complex shoulder conditions such as an irreparable rotator cuff-deficient shoulder, cuff tear arthropathy, or severe glenoid bone loss, substantial problems may arise. Historically, hemiarthroplasty or glenoid grafting with total shoulder arthroplasty yielded inconsistent and unsatisfactory results. Underlying pathologies in patients who have an irreparable rotator cuff-deficient shoulder, cuff tear arthropathy, or severe glenoid bone loss can considerably alter the mechanical function of the shoulder and create treatment dilemmas that are difficult to overcome. A better biomechanical understanding of these pathologic adaptations has improved treatment options. In the past three decades, reverse total shoulder arthroplasty was developed to treat these complex shoulder conditions not by specifically re-creating the anatomy but by using the remaining functional tissue to improve shoulder balance. Reverse total shoulder arthroplasty has achieved reliable improvements in both pain and function. Initial implant designs lacked scientific evidence to support the design rationale, and many implants failed because surgeons did not completely understand the forces involved or the pathology being treated. Implant function and clinical results will continue to improve as surgeons' biomechanical understanding of shoulder disease and reverse shoulder arthroplasty implants increases.
Young, Simon W; Zhu, Mark; Walker, Cameron G; Poon, Peter C
2013-05-15
Rotator cuff-tear arthropathy has traditionally represented a challenge to the shoulder arthroplasty surgeon. The poor results of conventional total shoulder arthroplasty in rotator-cuff-deficient shoulders due to glenoid component loosening have led to hemiarthroplasty being the traditional preferred surgical option. Recently, reverse total shoulder arthroplasty has gained increasing popularity because of a clinical perception of an improved functional outcome, despite the lack of comparative data. The aim of this study was to compare the early functional results of hemiarthroplasty with those of reverse shoulder arthroplasty in the management of cuff-tear arthropathy. The results of 102 primary hemiarthroplasties for rotator cuff-tear arthropathy were compared with those of 102 reverse shoulder arthroplasties performed for the same diagnosis. Patients were identified from the New Zealand Joint Registry and matched for age, sex, and American Society of Anesthesiologists (ASA) scores. Oxford Shoulder Scores (OSS) collected at six months postoperatively as well as mortality and revision rates were compared between the two groups. There were fifty-one men and fifty-one women in each group, with a mean age of 71.6 years in the hemiarthroplasty group and 72.6 years in the reverse shoulder arthroplasty group. The mean OSS at six months was 31.1 in the hemiarthroplasty group and 37.5 in the reverse shoulder arthroplasty group. At the time of follow-up, there were nine revisions in the hemiarthroplasty group and five in the reverse shoulder arthroplasty group. No difference in mortality rate was seen between the two groups. In this unselected population with rotator cuff-tear arthropathy, controlled for age, sex, and ASA score, reverse shoulder arthroplasty resulted in a functional outcome that was superior to that of hemiarthroplasty. Longer-term follow-up is needed to confirm these findings.
Holschen, M; Franetzki, B; Witt, K-A; Liem, D; Steinbeck, J
2017-08-01
Is reverse total shoulder arthroplasty a feasible treatment option for failed shoulder arthroplasty? A retrospective study of 44 cases with special regards to stemless and stemmed primary implants. Due to humeral or glenoid bone-loss and rotator cuff insufficiency reverse total shoulder arthroplasty often means the only remaining treatment option in revision shoulder arthroplasty. This study investigates the clinical outcome of patients treated with a reverse total shoulder in revision cases with special regard to stemless and stemmed primary implants. From 2010 to 2012 60 failed shoulder arthroplasties were converted to reverse total shoulder arthroplasty. Forty-four patients were available for follow-up after a mean of 24 months. Patients were assessed with X-rays, Constant- and ASES Score and a questionnaire about their subjective satisfaction. The total number of observed complications was seven (16%). Ninety-eight percent of the patients were satisfied with their clinical result. Patients achieved a mean normalized constant score of 70.2% and a mean ASES Score of 65.3. Patients with stemless primary implants achieved a higher normalized constant score than patients with stemmed primary implants (82 vs. 61.8%; p = 0009). Reverse total shoulder arthroplasty provides satisfactory clinical results and a high patient satisfaction in revision shoulder arthroplasty. The complication rate needs to be considered and discussed with the patient prior to surgery. Presence or absence of a stem of revised shoulder arthroplasties interferes with the outcome. LEVEL OF EVIDENCE IV: (Retrospective study).
Composite Materials for Maxillofacial Prostheses.
1979-08-01
block number) MAXILLOFACIAL PROSTHESES; PROSTHETIC MATERIALS; MICROCAPSULES ; SOFT FILLERS; ELASTuMER COMPOSITES 20,_ ABSTRACT ’Continue on reverse side...approaches were pursued toward making such microcapsules . One approach involves coaxial extrusion of a catalyzed elastomer precursor and core liquid into a...fabrication of maxillofacial prostheses. The projected composite systems are elastomeric-shelled, liquid-filled microcapsules . Two experimental approaches were
A novel dynamic mechanical testing technique for reverse shoulder replacements.
Dabirrahmani, Danè; Bokor, Desmond; Appleyard, Richard
2014-04-01
In vitro mechanical testing of orthopedic implants provides information regarding their mechanical performance under simulated biomechanical conditions. Current in vitro component stability testing methods for reverse shoulder implants are based on anatomical shoulder designs, which do not capture the dynamic nature of these loads. With glenoid component loosening as one of the most prevalent modes of failure in reverse shoulder replacements, it is important to establish a testing protocol with a more realistic loading regime. This paper introduces a novel method of mechanically testing reverse shoulder implants, using more realistic load magnitudes and vectors, than is currently practiced. Using a custom made jig setup within an Instron mechanical testing system, it is possible to simulate the change in magnitude and direction of the joint load during arm abduction. This method is a step towards a more realistic testing protocol for measuring reverse shoulder implant stability.
Reverse shoulder arthroplasty.
Jarrett, Claudius D; Brown, Brandon T; Schmidt, Christopher C
2013-07-01
The reverse shoulder arthroplasty is considered to be one of the most significant technological advancements in shoulder reconstructive surgery over the past 30 years. It is able to successfully decrease pain and improve function for patients with rotator cuff-deficient shoulders. The glenoid is transformed into a sphere that articulates with a humeral socket. The current reverse prosthesis shifts the center of rotation more medial and distal, improving the deltoid's mechanical advantage. This design has resulted in successful improvement in both active shoulder elevation and in quality of life. Copyright © 2013 Elsevier Inc. All rights reserved.
Formation of a physiological reverse shoulder joint.
Lerner, Markus; Turkmen, Ismail; Bernd, Ludger
2016-01-20
Congenital shoulder deformities are rarely seen in orthopaedic practice. Proximal humeral defects and glenoid hypoplasia have been reported separately in the literature. We present a case involving a 31-year-old woman having a cosmetic problem with her upper arm who was diagnosed with reverse shoulder joint deformity. This article presents the clinical, radiological and biomechanical findings of a physiological reverse shoulder joint. This is the first such reported case. 2016 BMJ Publishing Group Ltd.
Design and evaluation of prosthetic shoulder controller
Barton, Joseph E.; Sorkin, John D.
2015-01-01
We developed a 2-degree-of-freedom (DOF) shoulder position transducer (sensing shoulder protraction-retraction and elevation-depression) that can be used to control two of a powered prosthetic humerus' DOFs. We also developed an evaluation protocol based on Fitts' law to assess the performance of our device. The primary motivation for this work was to support development of powered prosthetic shoulder joints of a new generation of prosthetic arms for people with shoulder disarticulation and very high-level transhumeral amputation. We found that transducers that provided resistance to shoulder movement performed better than those providing no resistance. We also found that a position control scheme, where effector position is proportional to shoulder position, performed better than a velocity control scheme, where effector velocity is proportional to shoulder position. More generally, our transducer can be used to control motion along any two DOFs. It can also be used in a more general 4-DOF control scheme by sequentially controlling two DOFs at a time. The evaluation protocol has general applicability for researchers and practitioners. Researchers can employ it to compare different prosthesis designs and control schemes, while practitioners may find the evaluation protocol useful in evaluating and training people with amputation in the use of prostheses. PMID:25357185
Losier, Y; Englehart, K; Hudgins, B
2007-01-01
The integration of multiple input sources within a control strategy for powered upper limb prostheses could provide smoother, more intuitive multi-joint reaching movements based on the user's intended motion. The work presented in this paper presents the results of using myoelectric signals (MES) of the shoulder area in combination with the position of the shoulder as input sources to multiple linear discriminant analysis classifiers. Such an approach may provide users with control signals capable of controlling three degrees of freedom (DOF). This work is another important step in the development of hybrid systems that will enable simultaneous control of multiple degrees of freedom used for reaching tasks in a prosthetic limb.
Makhni, Eric C; Swart, Eric; Steinhaus, Michael E; Mather, Richard C; Levine, William N; Bach, Bernard R; Romeo, Anthony A; Verma, Nikhil N
2016-09-01
To compare the cost-effectiveness within the United States health care system of arthroscopic rotator cuff repair versus reverse total shoulder arthroplasty in patients with symptomatic large and massive rotator cuff tears without cuff-tear arthropathy. An expected-value decision analysis was constructed comparing the costs and outcomes of patients undergoing arthroscopic rotator cuff repair and reverse total shoulder arthroplasty for large and massive rotator cuff tears (and excluding cases of cuff-tear arthropathy). Comprehensive literature search provided input data to extrapolate costs and health utility states for these outcomes. The primary outcome assessed was that of incremental cost-effectiveness ratio (ICER) of reverse total shoulder arthroplasty versus rotator cuff repair. For the base case, both arthroscopic rotator cuff repair and reverse total shoulder were superior to nonoperative care, with an ICER of $15,500/quality-adjusted life year (QALY) and $37,400/QALY, respectively. Arthroscopic rotator cuff repair was dominant over primary reverse total shoulder arthroplasty, with lower costs and slightly improved clinical outcomes. Arthroscopic rotator cuff repair was the preferred strategy as long as the lifetime progression rate from retear to end-stage cuff-tear arthropathy was less than 89%. However, when the model was modified to account for worse outcomes when reverse shoulder arthroplasty was performed after a failed attempted rotator cuff repair, primary reverse total shoulder had superior outcomes with an ICER of $90,000/QALY. Arthroscopic rotator cuff repair-despite high rates of tendon retearing-for patients with large and massive rotator cuff tears may be a more cost-effective initial treatment strategy when compared with primary reverse total shoulder arthroplasty and when assuming no detrimental impact of previous surgery on outcomes after arthroplasty. Clinical judgment should still be prioritized when formulating treatment plans for these patients. LEVEL OF EVIDENCE: Level II, economic decision analysis. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Magosch, P; Habermeyer, P; Lichtenberg, S; Tauber, M; Gohlke, F; Mauch, F; Boehm, D; Loew, M; Zeifang, F; Pötzl, W
2017-12-01
Anatomic shoulder arthroplasty in osteoarthritis with biconcave glenoid wear results in decreased functional results and a higher rate of early glenoid loosening. The aim of the data analysis of the German shoulder arthroplasty register was to clarify whether reverse shoulder arthroplasty can provide better functional results and a lower complication rate than anatomic arthroplasty in osteoarthritis with biconcave glenoid wear. The analysis included 1052 completely documented primary implanted arthroplasties with a minimum follow-up of 2 years. In 119 cases, a B2-type glenoid was present. Out of these cases, 86 were treated with an anatomic shoulder arthroplasty, and in 33 cases a reverse shoulder arthroplasty was implanted. The mean follow-up was 47.6 months. The Constant score with its subcategories, as well as the active range of movement improved significantly after anatomic and after reverse shoulder arthroplasty. We observed no difference in functional results between both types of arthroplasty; however, reverse arthroplasty showed a significant higher revision rate (21.2%) (3% glenoid loosening, 6% prosthetic instability) than anatomic shoulder arthroplasty (12.8%) (11.6% glenoid loosening, 1.2% prosthetic instability), whereas anatomic shoulder arthroplasty showed a higher rate of glenoid loosening. Functional and radiographic results of both types of arthroplasty are comparable with the results reported in the literature, although our analysis represents results from an implant registry (data pertaining to medical care quality).
Dosari, Mohamed Al Ateeq Al; Hameed, Shamsi; Mukhtar, Khalid; Elmhiregh, Aissam
2017-01-01
The usual indication for reverse shoulder arthroplasty is glenohumeral arthritis with inadequate rotator cuff and intact deltoid muscle. We report here a case of reverse shoulder arthroplasty using a lattisimus dorsi flap in a patient with deltoid-deficient shoulder following a gunshot injury. The patient was an otherwise healthy 51-year-old male with a history of gunshot injury of the left shoulder 2006. Upon presentation in 2011, the patient had a loss of most of his shoulder bony and muscular structures. Due to deltoid muscle deficiency, the patient underwent Lattisimus Dorsi muscle flap followed by reverse shoulder arthroplasty in order to establish an upper limb function. Upon discharge, 11days after the surgery, the patient was able to achieve 150° flexion and 90° abduction while in the supine position and 45° in each direction, while sitting. He was able to perform internal rotation (behind back) up to the level of the L1 vertebra, assisted active abduction of 90°, and external rotation of 20°. Power tests showed power of grade 4/5 for both shoulder flexion and extension and grade 2+/5 for both abduction and adduction. At the last follow up one year after the operation, The patient still had passive pain-free full range of motion, but no progress in active range of motion beyond that upon discharge. Reverse shoulder arthroplasty after Latissmus dori flap in patient with deltoid deficient shoulders can be a successful and reproducible approach to treat such conditions. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Boileau, Pascal; Moineau, Grégory; Roussanne, Yannick; O'Shea, Kieran
2011-09-01
Scapular notching, prosthetic instability, limited shoulder rotation and loss of shoulder contour are associated with conventional medialized design reverse shoulder arthroplasty. Prosthetic (ie, metallic) lateralization increases torque at the baseplate-glenoid interface potentially leading to failure. We asked whether bony lateralization of reverse shoulder arthroplasty would avoid the problems caused by humeral medialization without increasing torque or shear force applied to the glenoid component. We prospectively followed 42 patients with rotator cuff deficiency treated with bony increased-offset reverse shoulder arthroplasty. A cylinder of autologous cancellous bone graft, harvested from the humeral head, was placed between the reamed glenoid surface and baseplate. Graft and baseplate fixation was achieved using a lengthened central peg (25 mm) and four screws. Patients underwent clinical, radiographic, and CT assessment at a minimum of 2 years after surgery. The humeral graft incorporated completely in 98% of cases (41 of 42) and partially in one. At a mean of 28 months postoperatively, no graft resorption, glenoid loosening, or postoperative instability was observed. Inferior scapular notching occurred in 19% (eight of 42). The absolute Constant-Murley score improved from 31 to 67. Thirty-six patients (86%) were able to internally rotate sufficiently to reach their back over the sacrum. Grafting of the glenoid surface during reverse shoulder arthroplasty effectively creates a long-necked scapula, providing the benefits of lateralization. Bony increased-offset reverse shoulder arthroplasty is associated with low rates of inferior scapular notching, improved shoulder rotation, no prosthetic instability and improved shoulder contour. In contrast to metallic lateralization, bony lateralization has the advantage of maintaining the prosthetic center of rotation at the prosthesis-bone interface, thus minimizing torque on the glenoid component. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Hierarchy of stability factors in reverse shoulder arthroplasty.
Gutiérrez, Sergio; Keller, Tony S; Levy, Jonathan C; Lee, William E; Luo, Zong-Ping
2008-03-01
Reverse shoulder arthroplasty is being used more frequently to treat irreparable rotator cuff tears in the presence of glenohumeral arthritis and instability. To date, however, design features and functions of reverse shoulder arthroplasty, which may be associated with subluxation and dislocation of these implants, have been poorly understood. We asked: (1) what is the hierarchy of importance of joint compressive force, prosthetic socket depth, and glenosphere size in relation to stability, and (2) is this hierarchy defined by underlying and theoretically predictable joint contact characteristics? We examined the intrinsic stability in terms of the force required to dislocate the humerosocket from the glenosphere of eight commercially available reverse shoulder arthroplasty devices. The hierarchy of factors was led by compressive force followed by socket depth; glenosphere size played a much lesser role in stability of the reverse shoulder arthroplasty device. Similar results were predicted by a mathematical model, suggesting the stability was determined primarily by compressive forces generated by muscles.
Stroud, Nicholas J; DiPaola, Matthew J; Martin, Brian L; Steiler, Cindy A; Flurin, Pierre-Henri; Wright, Thomas W; Zuckerman, Joseph D; Roche, Christopher P
2013-11-01
Numerous glenoid implant designs have been introduced into the global marketplace in recent years; however, little comparative biomechanical data exist to substantiate one design consideration over another. This study dynamically evaluated reverse shoulder glenoid baseplate fixation and compared the initial fixation associated with 2 reverse shoulder designs having an equivalent center of rotation in low-density and high-density bone substitute substrates. Significant differences in fixation were observed between implant designs, where the circular-porous reverse shoulder was associated with approximately twice the micromotion per equivalent test than the oblong-grit-blasted design. Additionally, 6 of the 7 circular-porous reverse shoulders failed catastrophically in the low-density bone model at an average of 2603 ± 981 cycles. None of the oblong-grit-blasted designs failed in the low-or high-density bone models and none of the circular-porous designs failed in the high-density bone models after 10,000 cycles of loading. These results demonstrate that significant differences in initial fixation exist between reverse shoulder implants having an equivalent center of rotation and suggest that design parameters, other than the position of the center of rotation, significantly affect fixation in low-density and high-density polyurethane bone substitutes. Subtle changes in glenoid baseplate design can dramatically affect fixation, particularly in low-density bone substitutes that are intended to simulate the bone quality of the recipient population for reverse shoulders. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Development of novel 3D-printed robotic prosthetic for transradial amputees.
Gretsch, Kendall F; Lather, Henry D; Peddada, Kranti V; Deeken, Corey R; Wall, Lindley B; Goldfarb, Charles A
2016-06-01
Upper extremity myoelectric prostheses are expensive. The Robohand demonstrated that three-dimensional printing reduces the cost of a prosthetic extremity. The goal of this project was to develop a novel, inexpensive three-dimensional printed prosthesis to address limitations of the Robohand. The prosthesis was designed for patients with transradial limb amputation. It is shoulder-controlled and externally powered with an anthropomorphic terminal device. The user can open and close all five fingers, and move the thumb independently. The estimated cost is US$300. After testing on a patient with a traumatic transradial amputation, several advantages were noted. The independent thumb movement facilitated object grasp, the device weighed less than most externally powered prostheses, and the size was easily scalable. Limitations of the new prosthetic include low grip strength and decreased durability compared to passive prosthetics. Most children with a transradial congenital or traumatic amputation do not use a prosthetic. A three-dimensional printed shoulder-controlled robotic prosthesis provides a cost effective, easily sized and highly functional option which has been previously unavailable. © The International Society for Prosthetics and Orthotics 2015.
Reverse shoulder arthroplasty due to glenoid bone defects.
Díaz Miñarro, J C; Izquierdo Fernández, A; Muñoz Reyes, F; Carpintero Lluch, R; Uceda Carrascosa, P; Muñoz Luna, F; López Jordán, A; Carpintero Benítez, P
2016-01-01
Reverse shoulder arthroplasty is becoming a useful tool for many diseases of the shoulder. Any severe glenoid bone defect may affect the fixing of the glenoid component. The aim of this paper is to evaluate the medium-term outcomes of reverse shoulder arthroplasty associated with a glenoplasty. A retrospective study was conducted on 5 patients from our hospital, selected due to glenoid defects of different etiology. All of them where treated with reverse shoulder arthroplasty associated with glenoplasty with bone graft. The minimum follow-up was one year (mean 30.4 months). All grafts were radiologically integrated, with no signs of resorption or necrosis being observed. At 12 months, the Constant score was 66.75 and the mean EVA score was 1. Glenoplasty surgery is technically demanding for restoring original bone size in patients with glenoid structural defects, enabling a reverse shoulder arthroplasty to be implanted. Thus improving both the function and clinical outcomes in selected patients with glenohumeral pathology and providing them with a solution. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Evaluation of transradial body-powered prostheses using a robotic simulator.
Ayub, Rafi; Villarreal, Dario; Gregg, Robert D; Gao, Fan
2017-04-01
Transradial body-powered prostheses are extensively used by upper-limb amputees. This prosthesis requires large muscle forces and great concentration by the patient, often leading to discomfort, muscle fatigue, and skin breakdown, limiting the capacity of the amputee to conduct daily activities. Since body-powered prostheses are commonplace, understanding their optimal operation to mitigate these drawbacks would be clinically meaningful. To find the optimal operation of the prosthesis where the activation force is minimized and the grip force is maximized. Experimental design. A computer-controlled robotic amputee simulator capable of rapidly testing multiple elbow, shoulder, and scapular combinations of the residual human arm was constructed. It was fitted with a transradial prosthesis and used to systematically test multiple configurations. We found that increased shoulder flexion, scapular abduction, elbow extension, and the placement of the ring harness near the vertebra C7 correlate with higher gripper operation efficiency, defined as the ratio of grip force to cable tension. We conclude that force transmission efficiency is closely related to body posture configuration. These results could help guide practitioners in clinical practice as well as motivate future studies in optimizing the operation of a body-powered prosthesis. Clinical relevance The results from this study suggest that clinicians ought to place the ring harness inferior and to the sound side of the vertebra prominens in order to maximize grip efficiency. The results will also help clinicians better instruct patients in body posture during prosthesis operation to minimize strain.
2018-02-13
Osteoarthritis; Rheumatoid Arthritis; Post-traumatic Arthritis; Ununited Humeral Head Fracture; Irreducible 3-and 4-part Proximal Humeral Fractures; Avascular Necrosis; Gross Rotator Cuff Deficiency; Failed Total Shoulder Arthroplasty (Both Glenoid and Humeral Components Require Revision
King, Joseph J; Nystrom, Lukas M; Reimer, Nickolas B; Gibbs, C Parker; Scarborough, Mark T; Wright, Thomas W
2016-01-01
Proximal humerus reconstructions after resection of tumors are challenging. Early success of the reverse shoulder arthroplasty for reconstructions has recently been reported. The reverse allograft-prosthetic composite offers the advantage of improved glenohumeral stability compared with hemiarthroplasty for proximal humeral reconstructions as it uses the deltoid for stability. This article describes the technique for treating proximal humeral tumors, including preoperative planning, biopsy principles, resection pearls, soft tissue tensioning, and specifics about reconstruction using the reverse allograft-prosthetic composite. Two cases are presented along with the functional outcomes with use of this technique. Biomechanical considerations during reconstruction are reviewed, including techniques to improve the deltoid compression force. Reported instability rates are less with reverse shoulder arthroplasty reconstruction as opposed to hemiarthroplasty or total shoulder arthroplasty reconstructions of tumor resections. Reported functional outcomes are promising for the reverse allograft-prosthetic composite reconstructions, although complications are reported. Reverse allograft-prosthetic composites are a promising option for proximal humeral reconstructions, although nonunion of the allograft-host bone junction continues to be a challenge for this technique. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Mattei, Lorenza; Di Puccio, Francesca; Joyce, Thomas J; Ciulli, Enrico
2016-08-01
Although huge research efforts have been devoted to wear analysis of ultra-high molecular weight polyethylene (UHMWPE) in hip and knee implants, shoulder prostheses have been studied only marginally. Recently, the authors presented a numerical wear model of reverse total shoulder arthroplasties (RTSAs), and its application for estimating the wear coefficient k from experimental data according to different wear laws. In this study, such model and k expressions are exploited to investigate the sensitivity of UHMWPE wear to implant size and dimensional tolerance. A set of 10 different geometries was analysed, considering nominal diameters in the range 36-42mm, available on the market, and a cup dimensional tolerance of +0.2, -0.0mm (resulting in a diametrical clearance ranging between 0.04-0.24mm), estimated from measurements on RTSAs. Since the most reliable wear law and wear coefficient k for UHMWPE are still controversial in the literature, both the Archard law (AR) and the wear law of UHMWPE (PE), as well as four different k expressions were considered, carrying out a total of 40 simulations. Results showed that the wear volume increases with the implant size and decreases with the dimensional tolerance for both the wear laws. Interestingly, different trends were obtained for the maximum wear depth vs. clearance: the best performing implants should have a high conformity according to the AR law but low conformity for the PE law. However, according to both laws, wear is highly affected by both implant size and dimensional tolerance, although it is much more sensitive to the latter, with up to a twofold variation of wear predicted. Indeed, dimensional tolerance directly alters the clearance, and therefore the lubrication and contact pressure distribution in the implant. Rather surprisingly the role of dimensional tolerance has been completely disregarded in the literature, as well as in the standards. Furthermore, this study notes some important issues for future work, such as the validation of wear laws and predictive wear models and the sensitivity of k to implant geometry. Copyright © 2016 Elsevier Ltd. All rights reserved.
Thangarajah, Tanujan; Higgs, Deborah; Bayley, J I L; Lambert, Simon M
2016-01-01
AIM: To report the results of fixed-fulcrum fully constrained reverse shoulder arthroplasty for the treatment of recurrent shoulder instability in patients with epilepsy. METHODS: A retrospective review was conducted at a single facility. Cases were identified using a computerized database and all clinic notes and operative reports were reviewed. All patients with epilepsy and recurrent shoulder instability were included for study. Between July 2003 and August 2011 five shoulders in five consecutive patients with epilepsy underwent fixed-fulcrum fully constrained reverse shoulder arthroplasty for recurrent anterior shoulder instability. The mean duration of epilepsy in the cohort was 21 years (range, 5-51) and all patients suffered from grand mal seizures. RESULTS: Mean age at the time of surgery was 47 years (range, 32-64). The cohort consisted of four males and one female. Mean follow-up was 4.7 years (range, 4.3-5 years). There were no further episodes of instability, and no further stabilisation or revision procedures were performed. The mean Oxford shoulder instability score improved from 8 preoperatively (range, 5-15) to 30 postoperatively (range, 16-37) (P = 0.015) and the mean subjective shoulder value improved from 20 (range, 0-50) preoperatively to 60 (range, 50-70) postoperatively (P = 0.016). Mean active forward elevation improved from 71° preoperatively (range, 45°-130°) to 100° postoperatively (range, 80°-90°) and mean active external rotation improved from 15° preoperatively (range, 0°-30°) to 40° (20°-70°) postoperatively. No cases of scapular notching or loosening were noted. CONCLUSION: Fixed-fulcrum fully constrained reverse shoulder arthroplasty should be considered for the treatment of recurrent shoulder instability in patients with epilepsy. PMID:27458554
Esteban, J; Alvarez-Alvarez, B; Blanco, A; Fernández-Roblas, R; Gadea, I; Garcia-Cañete, J; Sandoval, E; Valdazo, M
2013-07-01
We have designed a prospective study to evaluate the usefulness of prolonged incubation of cultures from sonicated orthopaedic implants. During the study period 124 implants from 113 patients were processed (22 osteosynthetic implants, 46 hip prostheses, 54 knee prostheses, and two shoulder prostheses). Of these, 70 patients had clinical infection; 32 had received antibiotics at least seven days before removal of the implant. A total of 54 patients had sonicated samples that produced positive cultures (including four patients without infection). All of them were positive in the first seven days of incubation. No differences were found regarding previous antibiotic treatment when analysing colony counts or days of incubation in the case of a positive result. In our experience, extending incubation of the samples to 14 days does not add more positive results for sonicated orthopaedic implants (hip and knee prosthesis and osteosynthesis implants) compared with a conventional seven-day incubation period.
Troncossi, Marco; Borghi, Corrado; Chiossi, Marco; Davalli, Angelo; Parenti-Castelli, Vincenzo
2009-05-01
The application of a design methodology for the determination of the optimal prosthesis architecture for a given upper limb amputee is presented in this paper along with the discussion of its results. In particular, a novel procedure was used to provide the main guidelines for the design of an actuated shoulder articulation for externally powered prostheses. The topology and the geometry of the new articulation were determined as the optimal compromise between wearability (for the ease of use and the patient's comfort) and functionality of the device (in terms of mobility, velocity, payload, etc.). This choice was based on kinematic and kinetostatic analyses of different upper limb prosthesis models and on purpose-built indices that were set up to evaluate the models from different viewpoints. Only 12 of the 31 simulated prostheses proved a sufficient level of functionality: among these, the optimal solution was an articulation having two actuated revolute joints with orthogonal axes for the elevation of the upper arm in any vertical plane and a frictional joint for the passive adjustment of the humeral intra-extra rotation. A prototype of the mechanism is at the clinical test stage.
Merolla, Giovanni; Tartarone, Antonio; Porcellini, Giuseppe
2016-01-01
Objectives: To obtain outcomes data on anatomical and reverse total shoulder arthroplasty by analysis of clinical scores and standard radiographs. Subject selection and enrollment: 400 consecutive series of patients replaced with anatomical and reverse total shoulder arthroplasty (minimum 3 years follow-up). Study Design: retrospective monocenter. Preoperative assessment: Demographics, clinical scores (Constant-Murley) as available, shoulder X-ray (AP, outlet and axillary views) . Last follow-up: Postoperative radiographhs and clinical scores. Adverse events and complications to be reported as occurred since implantation. Statistical analysis: Data collected will be summarized and analyzed for statistical significance. PMID:27326389
Klages, A; Hurschler, C; Wülker, N; Windhagen, H
2001-09-01
Modern shoulder prostheses permit an anatomic reconstruction of the joint, although the biomechanical advantages are not proven. The goal of this study was to investigate the relationship between position of the humeral head and function of the shoulder prosthesis (muscle efficiency). Shoulder elevation-motion and rotator cuff defects were simulated in vitro in a robot-assisted shoulder simulator. The EPOCA Custom Offset shoulder prosthesis (Argomedical AG, Cham, CH) was implanted in seven normal shoulders (77 +/- 20 kg, 55 +/- 14 years). Active elevation was simulated by hydraulic cylinders, and scapulothoratic motion by a specially programmed industrial robot. Muscle efficiency (elevation-angle/muscle-force of the deltoid muscle) was measured in anatomic (ANA), medialised (MED) and lateralised (LAT) positions of the humeral head, with or without rotator cuff muscle deficiency. Medialisation increased efficiency by 0.03 +/- 0.04 deg/N (p = 0.022), lateralisation decreased it by 0.04 +/- 0.06 deg/N (p = 0.009). Supraspinatus muscle deficiency increased the deltoid force required to elevate the arm, and thus decreased efficiency (ANA p = 0.091, MED p = 0.018, LAT p = 0.028). The data confirm that the position of the humeral head affects the mechanics of total shoulder arthroplasty. Medialisation increases efficiency of the deltoid muscle and may prove useful in compensating isolated supraspinatus muscle deficiency. Lateralisation, in contrast, leads to an unfavorable situation.
Glenoid bone grafting in primary reverse total shoulder arthroplasty.
Ernstbrunner, Lukas; Werthel, Jean-David; Wagner, Eric; Hatta, Taku; Sperling, John W; Cofield, Robert H
2017-08-01
Severe glenoid bone loss remains a challenge in patients requiring shoulder arthroplasty and may necessitate glenoid bone grafting. The purpose of this study was to determine results, complications, and rates of failure of glenoid bone grafting in primary reverse shoulder arthroplasty. Forty-one shoulders that underwent primary reverse arthroplasty between 2006 and 2013 with a minimum follow-up of 2 years (mean, 2.8 years; range, 2-6 years) were reviewed. Thirty-four (83%) received corticocancellous grafts and 7 (17%) structural grafts. Active range of motion and pain levels were significantly improved (P < .001), with mean American Shoulder and Elbow Surgeons score of 77, Simple Shoulder Test score of 9, and patient satisfaction of 93% at the most recent follow-up. Preoperative severe glenoid erosion and increasing body mass index were significantly associated with worse American Shoulder and Elbow Surgeons scores (P = .04). On radiographic evaluation, 7 patients (18%) had grade 1 or grade 2 glenoid lucency. Glenoid bone graft incorporation was observed in 31 patients (78%). Twelve patients (30%) suffered from grade 1 or grade 2 scapular notching. All of the patients with structural grafts showed graft incorporation and no signs of glenoid lucency. Although glenoid lucency, glenoid graft resorption, and scapular notching were present at short-term to midterm follow-up, none of the patients needed revision surgery. Primary reverse shoulder arthroplasty with glenoid reconstruction using bone graft relieved pain and restored shoulder function and stability. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
The effect of surgeon and hospital volume on shoulder arthroplasty perioperative quality metrics.
Singh, Anshu; Yian, Edward H; Dillon, Mark T; Takayanagi, Miwa; Burke, Mary F; Navarro, Ronald A
2014-08-01
There has been a significant increase in both the incidence of shoulder arthroplasty and the number of surgeons performing these procedures. Literature regarding the relationship between surgeon or hospital volume and the performance of modern shoulder arthroplasty is limited. This study examines the effect of surgeon or hospital shoulder arthroplasty volume on perioperative metrics related to shoulder hemiarthroplasty, total shoulder arthroplasty, and reverse shoulder arthroplasty. Blood loss, length of stay, and operative time were the main endpoints analyzed. Prospective data were analyzed from a multicenter shoulder arthroplasty registry; 1176 primary shoulder arthroplasty cases were analyzed. Correlation and analysis of covariance were used to examine the association between surgeon and hospital volume and perioperative metrics adjusting for age, sex, and body mass index. Surgeon volume is inversely correlated with length of stay for hemiarthroplasty and total shoulder arthroplasty and with blood loss and operative time for all 3 procedures. Hospital volume is inversely correlated with length of stay for hemiarthroplasty, with blood loss for total and reverse shoulder arthroplasty, and with operative time for all 3 procedures. High-volume surgeons performed shoulder arthroplasty 30 to 50 minutes faster than low-volume surgeons did. Higher surgeon and hospital case volumes led to improved perioperative metrics with all shoulder arthroplasty procedures, including reverse total shoulder arthroplasty, which has not been previously described in the literature. Surgeon volume had a larger effect on metrics than hospital volume did. This study supports the concept that complex shoulder procedures are, on average, performed more efficiently by higher volume surgeons in higher volume centers. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Mastrokalos, Dimitrios S; Panagopoulos, Georgios N; Galanopoulos, Ioannis P; Papagelopoulos, Panayiotis J
2017-10-01
Management of a posterior shoulder dislocation with an associated reverse Hill-Sachs lesion is challenging, both diagnostically and therapeutically. Diagnosis is frequently delayed or missed, whereas the resulting humeral head defect is often larger and more difficult to salvage than in anterior shoulder dislocations. This report presents the case of a 29-year-old male with a recurrent posterior shoulder dislocation associated with a large reverse Hill-Sachs defect, treated with bone augmentation of the lesion with a combination of fresh femoral head allograft and a locally harvested humeral head autograft transfer, with a successful outcome. Level of evidence V.
Henninger, Heath B; King, Frank K; Tashjian, Robert Z; Burks, Robert T
2014-05-01
Numerous studies have examined the biomechanics of isolated variables in reverse total shoulder arthroplasty. This study directly compared the composite performance of two reverse total shoulder arthroplasty systems; each system was designed around either a medialized or a lateralized glenohumeral center of rotation. Seven pairs of shoulders were tested on a biomechanical simulator. Center of rotation, position of the humerus, passive and active range of motion, and force to abduct the arm were quantified. Native arms were tested, implanted with a Tornier Aequalis or DJO Surgical Reverse Shoulder Prosthesis (RSP), and then retested. Differences from the native state were then documented. Both systems shifted the center of rotation medially and inferiorly relative to native. Medial shifts were greater in the Aequalis implant (P < .037). All humeri shifted inferior compared with native but moved medially with the Aequalis (P < .001). Peak passive abduction, internal rotation, and external rotation did not differ between systems (P > .05). Both reverse total shoulder arthroplasty systems exhibited adduction deficits, but the RSP implant deficit was smaller (P = .046 between implants). Both systems reduced forces to abduct the arm compared with native, although the Aequalis required more force to initiate motion from the resting position (P = .022). Given the differences in system designs and configurations, outcome variables were generally comparable. The RSP implant allowed slightly more adduction, had a more lateralized humeral position, and required less force to initiate elevation. These factors may play roles in limiting scapular notching, improving active external rotation by normalizing the residual rotator cuff length, and limiting excessive stress on the deltoid. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Effect of Humeral Component Version on Outcomes in Reverse Shoulder Arthroplasty.
Aleem, Alexander W; Feeley, Brian T; Austin, Luke S; Ma, C Benjamin; Krupp, Ryan J; Ramsey, Matthew L; Getz, Charles L
2017-05-01
Although reverse shoulder arthroplasty provides excellent clinical results in appropriately selected patients, loss of external and internal rotation may occur. Component selection, design, and placement affect postoperative results. Recent studies considered the effect of humeral component version on functional results. The current study investigated whether humeral stem retroversion affects the outcomes of reverse shoulder arthroplasty with a retrospective review of a multisurgeon, industry-sponsored, prospectively gathered database of a single reverse shoulder arthroplasty implant. All patients had at least 2-year follow-up. Clinical outcomes, including American Shoulder and Elbow Surgeons score, visual analog scale pain score, Short Form-12 Mental and Physical Component scores, range of motion, and internal rotation function, were compared between patients with humeral retroversion of 10° or less (group A) and those with humeral retroversion of 20° or greater (group B). Radiographic outcomes were compared. The analysis included 64 patients (group A, 29 patients; group B, 35 patients). No clinical or statistically significant difference was found in American Shoulder and Elbow Surgeons scores. Both groups showed statistical and clinical improvement vs preoperative scores, with group A averaging 77.8 and group B averaging 79.2 at final follow-up. No differences were found between groups in range of motion or ability to perform tasks that require shoulder internal rotation. Patients can expect good clinical improvement after reverse shoulder arthroplasty. No difference was found in clinical or radiologic outcomes based on humeral component retroversion. Despite the theoretical increase in external rotation when the humeral component is placed closer to native retroversion, the results did not show this effect. [Orthopedics. 2017; 40(3):179-186.]. Copyright 2017, SLACK Incorporated.
Reverse total shoulder arthroplasty: research models
PETRILLO, STEFANO; LONGO, UMILE GIUSEPPE; GULOTTA, LAWRENCE V.; BERTON, ALESSANDRA; KONTAXIS, ANDREAS; WRIGHT, TIMOTHY; DENARO, VINCENZO
2016-01-01
Purpose the past decade has seen a considerable increase in the use of research models to study reverse total shoulder arthroplasty (RTSA). Nevertheless, none of these models has been shown to completely reflect real in vivo conditions. Methods we performed a systematic review of the literature matching the following key words: “reverse total shoulder arthroplasty” or “reverse total shoulder replacement” or “reverse total shoulder prosthesis” and “research models” or “biomechanical models” or “physical simulators” or “virtual simulators”. The following databases were screened: Medline, Google Scholar, EMBASE, CINAHIL and Ovid. We identified and included all articles reporting research models of any kind, such as physical or virtual simulators, in which RTSA and the glenohumeral joint were reproduced. Results computer models and cadaveric models are the most commonly used, and they were shown to be reliable in simulating in vivo conditions. Bone substitute models have been used in a few studies. Mechanical testing machines provided useful information on stability factors in RTSA. Conclusion because of the limitations of each individual model, additional research is required to develop a research model of RTSA that may reduce the limitations of those presently available, and increase the reproducibility of this technique in the clinical setting. PMID:28217660
Kim, Seok-Gyu; Park, Jae-Uk; Jeong, Jae-Heon; Bae, Chang; Bae, Tae-Soo; Chee, Winston
2009-01-01
The purpose of this study was to evaluate the clinical efficacy of implant prostheses retained by screws and cement (SCPs) by examining the reverse torque values (RTVs) of the abutment screws and the marginal openings of the implant prostheses. Two implants (3.8 x 13 mm; Camlog Biotechnologies) were embedded in an acrylic resin block 5 mm apart. Eighteen copies of this resin specimen were fabricated and randomly divided into two groups. Two-unit implant prostheses with two different designs-purely cement-retained implant prostheses (group 1) and SCPs (group 2)-were made out of type IV gold alloy and placed on the implants. After tightening to about 30 Ncm, the preloading RTVs of the abutment screws were measured. After retightening the abutment screws or cementing the prostheses, followed by cyclic loading, the postloading RTVs of the abutment screws were examined. Also, the marginal openings of the prostheses in the two groups were measured under a stereomicroscope. These measurements were compared statistically. The postloading RTVs and their differences from the preloading RTVs of the abutment screws demonstrated no significant differences between groups (P > .05). Group 2 prostheses showed significantly smaller marginal openings than group 1 prostheses (P < .05). The forces generated when torquing the abutment screw of the SCP did not cause more loosening of the abutment screws than the purely cement-retained implant prosthesis. The SCP showed better marginal adaptation of the cement-retained part than the purely cement-retained implant prosthesis, possibly as a result of the screw-retained abutment seating the restoration. Within the limitations of this in vitro test, the SCP showed no significant difference in RTV of the abutment screw and a smaller marginal gap compared to a purely cement-retained implant prosthesis.
Use of a shorter humeral stem in revision reverse shoulder arthroplasty.
Wagner, Eric R; Statz, Joseph M; Houdek, Matthew T; Cofield, Robert H; Sánchez-Sotelo, Joaquín; Sperling, John W
2017-08-01
The purpose of this study was to examine the outcomes of revision reverse arthroplasty using short bone-preserving humeral components in revising a long-stemmed component. During a 7-year period, 39 patients who underwent revision reverse shoulder arthroplasty using the long to short humeral component technique were included. The mean age was 72 years. Prior implants used in the primary setting included anatomic (n = 26), hemiarthroplasty (n = 11), and reverse (n = 2). At a follow-up of 3 years (2-5), 5 shoulders (13%) required revision surgery, including 1 for a periprosthetic humerus fracture and 4 for glenoid component loosening. The survival free of revision for any reason and revision for humeral disease was 84% and 94%, respectively. One patient experienced a nondisplaced greater tuberosity fracture at 18 months postoperatively that healed without operative intervention. There were no dislocations or infections. Overall, patients experienced excellent overall improvements in their pain levels and shoulder motion (P < .001), with a postoperative 91% satisfaction rate as well as postoperative American Shoulder and Elbow Surgeons score of 68 and Simple Shoulder Test score of 6.7. At most recent radiographic follow-up, 1 (5%) patient had grade 3 humeral lucency. Preserving bone stock through conversion to a shorter reverse humeral stem in the revision setting is a reasonable option with good short- to intermediate-term results and low rates of humeral complications. Using the shorter stem components provides adequate stability and high rates of humeral component ingrowth. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Irlenbusch, U; Kohut, G
2015-04-01
To minimize notching problem associated with reversed prostheses, inferior positioning of base plate is recommended. This reduces the risk of notching, but does not eliminate it completely. Both polyethylene/PE-induced osteolysis and implant-to-bone or implant-to-implant contact may still occur, contributing to the risk of screw-breakage and resulting long-term failure. Therefore, the stability and integration of a newly developed base plate without inferior screw and inversion of bearing materials was investigated. Biomechanical assessment of primary stability of the two types of glenoid baseplate (1- and 2-pegged) was carried out according to ASTM F-2028-02 (American Society for Testing and Materials). Patients with a follow-up period of at least 2 years were clinically (n=78) and for most of them radiologically (n=61) examined. The X-rays were evaluated for loosening and scapular notching. The mean values of micromotions after 100,000 cycles showed no relevant differences between the 2-peg and the 1-peg base plates (47 μm for the 2-peg design and 43 μm for the 1-peg design), i.e. both were below the borderline for secure Osseointegration of 150 μm. Radiologically, no signs of loosening or radiolucent lines/RLL were found for both base plates. The mean incidence of inferior scapular notching was 23.6% (42 mm glenoid sphere: 15.8%). Only grade 1 and grade 2 notching was observed. Additionally as result of absence of PE-induced osteolysis shape, size, borderline and location of notching differed from those observed with conventional reverse total shoulder arthroplasty bearing materials. In combination with modified inferior operating technique, the newly designed implant has the potential to reduce the incidence of scapular notching and to avoid both PE-induced osteolysis and metal-screw contact. The new design did not compromise stability of the base plate in any way during the investigation period, as demonstrated both by the data from the biomechanical investigation and also by the radiological follow-up. Level III, case-control study. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Raiss, Patric; Zeifang, Felix; Pons-Villanueva, Juan; Smithers, Christopher J; Loew, Markus; Walch, Gilles
2014-07-01
Osteoarthritis in combination with rotator cuff deficiency following previous shoulder stabilisation surgery and after failed surgical treatment for chronic anterior shoulder dislocation is a challenging condition. The aim of this study was to analyse the results of reverse shoulder arthroplasty in such patients. Thirteen patients with a median follow-up of 3.5 (range two to eight) years and a median age of 70 (range 48-82) years were included. In all shoulders a tear of at least one rotator cuff tendon in combination with osteoarthritis was present at the time of arthroplasty. The Constant score, shoulder flexion and external and internal rotation with the elbow at the side were documented pre-operatively and at the final follow-up. Pre-operative, immediate post-operative and final follow-up radiographs were analysed. All complications and revisions were documented. Twelve patients were either satisfied or very satisfied with the procedure. The median Constant score increased from 26 points pre-operatively to 67 points at the final follow-up (p = 0.001). The median shoulder flexion increased significantly from 70° to 130° and internal rotation from two to four points (p = 0.002). External rotation did not change significantly (p = 0.55). Glenoid notching was present in five cases and was graded as mild in three cases and moderate in two. One complication occurred leading to revision surgery. Reverse arthroplasty leads to high satisfaction rates for patients with osteoarthritis and rotator cuff deficiency who had undergone previous shoulder stabilisation procedures. The improvements in clinical outcome as well as the radiographic results seem to be comparable with those of other studies reporting on the outcome of reverse shoulder arthroplasty for other conditions.
Pompa, Giorgio; Di Carlo, Stefano; De Angelis, Francesca; Cristalli, Maria Paola; Annibali, Susanna
2015-01-01
This study assessed whether there are differences in marginal fit between laser-fusion and conventional techniques to produce fixed dental prostheses (FDPs). A master steel die with 2 abutments was produced to receive a posterior 4-unit FDPs and single copings. These experimental models were divided into three groups (n = 20/group) manufactured: group 1, Ni-Cr alloy, with a lost-wax casting technique; group 2, Co-Cr alloy, with selective laser melting (SLM); and group 3, yttria-tetragonal zirconia polycrystal (Y-TZP), with a milling system. All specimens were cut along the longitudinal axis and their adaptation was measured at the marginal and shoulder areas on the right and left sides of each abutment. Measurements were made using a stereomicroscope (×60 magnification) and a scanning electron microscope (×800 magnification). The data were analyzed using one-way analysis of variance and the Bonferroni post hoc test, with a significance cutoff of 5%. Significant differences (P < 0.05) were observed between group 3 and the other groups. The marginal opening was smallest with Co-Cr alloy substructures, while the shoulder opening was smallest with Ni-Cr alloy substructures. Within the limitations of this study, the marginal fit of an FDP is better with rapid prototyping (RP) via SLM than conventional manufacturing systems.
Henninger, Heath B; Barg, Alexej; Anderson, Andrew E; Bachus, Kent N; Tashjian, Robert Z; Burks, Robert T
2012-04-01
No clear recommendations exist regarding optimal humeral component version and deltoid tension in reverse total shoulder arthroplasty (TSA). A biomechanical shoulder simulator tested humeral versions (0°, 10°, 20° retroversion) and implant thicknesses (-3, 0, +3 mm from baseline) after reverse TSA in human cadavers. Abduction and external rotation ranges of motion as well as abduction and dislocation forces were quantified for native arms and arms implanted with 9 combinations of humeral version and implant thickness. Resting abduction angles increased significantly (up to 30°) after reverse TSA compared with native shoulders. With constant posterior cuff loads, native arms externally rotated 20°, whereas no external rotation occurred in implanted arms (20° net internal rotation). Humeral version did not affect rotational range of motion but did alter resting abduction. Abduction forces decreased 30% vs native shoulders but did not change when version or implant thickness was altered. Humeral center of rotation was shifted 17 mm medially and 12 mm inferiorly after implantation. The force required for lateral dislocation was 60% less than anterior and was not affected by implant thickness or version. Reverse TSA reduced abduction forces compared with native shoulders and resulted in limited external rotation and abduction ranges of motion. Because abduction force was reduced for all implants, the choice of humeral version and implant thickness should focus on range of motion. Lateral dislocation forces were less than anterior forces; thus, levering and inferior/posterior impingement may be a more probable basis for dislocation (laterally) than anteriorly directed forces. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
The accuracy and precision of radiostereometric analysis in upper limb arthroplasty.
Ten Brinke, Bart; Beumer, Annechien; Koenraadt, Koen L M; Eygendaal, Denise; Kraan, Gerald A; Mathijssen, Nina M C
2017-06-01
Background and purpose - Radiostereometric analysis (RSA) is an accurate method for measurement of early migration of implants. Since a relation has been shown between early migration and future loosening of total knee and hip prostheses, RSA plays an important role in the development and evaluation of prostheses. However, there have been few RSA studies of the upper limb, and the value of RSA of the upper limb is not yet clear. We therefore performed a systematic review to investigate the accuracy and precision of RSA of the upper limb. Patients and methods - PRISMA guidelines were followed and the protocol for this review was published online at PROSPERO under registration number CRD42016042014. A systematic search of the literature was performed in the databases Embase, Medline, Cochrane, Web of Science, Scopus, Cinahl, and Google Scholar on April 25, 2015 based on the keywords radiostereometric analysis, shoulder prosthesis, elbow prosthesis, wrist prosthesis, trapeziometacarpal joint prosthesis, humerus, ulna, radius, carpus. Articles concerning RSA for the analysis of early migration of prostheses of the upper limb were included. Quality assessment was performed using the MINORS score, Downs and Black checklist, and the ISO RSA Results - 23 studies were included. Precision values were in the 0.06-0.88 mm and 0.05-10.7° range for the shoulder, the 0.05-0.34 mm and 0.16-0.76° range for the elbow, and the 0.16-1.83 mm and 11-124° range for the TMC joint. Accuracy data from marker- and model-based RSA were not reported in the studies included. Interpretation - RSA is a highly precise method for measurement of early migration of orthopedic implants in the upper limb. However, the precision of rotation measurement is poor in some components. Challenges with RSA in the upper limb include the symmetrical shape of prostheses and the limited size of surrounding bone, leading to over-projection of the markers by the prosthesis. We recommend higher adherence to RSA guidelines and encourage investigators to publish long-term follow-up RSA studies.
Scalise, J; Jaczynski, A; Jacofsky, M
2016-02-01
The eccentric glenosphere was principally introduced into reverse shoulder arthroplasty to reduce the incidence of scapular notching. There is only limited information about the influence of its design on deltoid power and joint reaction forces. The aim of our study was to investigate how the diameter and eccentricity of the glenosphere affect the biomechanics of the deltoid and the resultant joint reaction forces. Different sizes of glenosphere and eccentricity were serially tested in ten cadaveric shoulders using a custom shoulder movement simulator. Increasing the diameter of the glenosphere alone did not alter the deltoid moment arm. However, using an eccentric glenosphere increased the moment arm of the deltoid, lowered the joint reaction force and required less deltoid force to generate movement. Eccentricity is an independent variable which increases deltoid efficiency and lowers joint reaction forces in a reverse shoulder arthroplasty. Cite this article: Bone Joint J 2016;98-B:218-23. ©2016 The British Editorial Society of Bone & Joint Surgery.
Favre, Philippe; Loeb, Michael D; Helmy, Naeder; Gerber, Christian
2008-01-01
In patients with pseudoparesis of the shoulder resulting from irreparable rotator cuff tears, reverse shoulder arthroplasty (RSA) can restore active elevation, but external rotation remains less predictable. Latissimus dorsi transfer (LDT) has been shown to be effective in restoring external rotation in patients with posterosuperior tears of the rotator cuff. The aim of this study is to determine the capacity of the LDT to restore external rotation in combination with RSA and to investigate the mechanical advantage produced by 3 different insertion sites. A biomechanical model was created using a reverse total shoulder prosthesis with 3 different transfer insertions. Moment arms were measured for 2 static positions and 1 motion of the humerus. The moment arm analysis showed that LDT can improve active external rotation in the setting of a reverse prosthesis. An insertion site on the posterior side of the greater tuberosity (adjacent to the teres minor insertion) produced a greater external rotation moment arm.
Complications in reverse shoulder arthroplasty
Barco, Raul; Savvidou, Olga D.; Sperling, John W.; Sanchez-Sotelo, Joaquín; Cofield, Robert H.
2016-01-01
The reported rate of complications of reverse shoulder arthroplasty (RSA) seems to be higher than the complication rate of anatomical total shoulder arthroplasty. The reported overall complication rate of primary RSA is approximately 15%; when RSA is used in the revision setting, the complication rate may approach 40%. The most common complications of RSA include instability, infection, notching, loosening, nerve injury, acromial and scapular spine fractures, intra-operative fractures and component disengagement. Careful attention to implant design and surgical technique, including implantation of components in the correct version and height, selection of the best glenosphere-humeral bearing match, avoidance of impingement, and adequate management of the soft tissues will hopefully translate in a decreasing number of complications in the future. Cite this article: Barco R, Savvidou OD, Sperling JW, Sanchez-Sotelo J, Cofield RH. Complications in reverse shoulder arthroplasty. EFORT Open Rev 2016;1:72-80. DOI: 10.1302/2058-5241.1.160003. PMID:28461931
Complications in reverse shoulder arthroplasty.
Barco, Raul; Savvidou, Olga D; Sperling, John W; Sanchez-Sotelo, Joaquín; Cofield, Robert H
2016-03-01
The reported rate of complications of reverse shoulder arthroplasty (RSA) seems to be higher than the complication rate of anatomical total shoulder arthroplasty.The reported overall complication rate of primary RSA is approximately 15%; when RSA is used in the revision setting, the complication rate may approach 40%.The most common complications of RSA include instability, infection, notching, loosening, nerve injury, acromial and scapular spine fractures, intra-operative fractures and component disengagement.Careful attention to implant design and surgical technique, including implantation of components in the correct version and height, selection of the best glenosphere-humeral bearing match, avoidance of impingement, and adequate management of the soft tissues will hopefully translate in a decreasing number of complications in the future. Cite this article: Barco R, Savvidou OD, Sperling JW, Sanchez-Sotelo J, Cofield RH. Complications in reverse shoulder arthroplasty. EFORT Open Rev 2016;1:72-80. DOI: 10.1302/2058-5241.1.160003.
Reverse total shoulder replacement for nonunion of a fracture of the proximal humerus.
Zafra, M; Uceda, P; Flores, M; Carpintero, P
2014-09-01
Patients with pain and loss of shoulder function due to nonunion of a fracture of the proximal third of the humerus may benefit from reverse total shoulder replacement. This paper reports a prospective, multicentre study, involving three hospitals and three surgeons, of 35 patients (28 women, seven men) with a mean age of 69 years (46 to 83) who underwent a reverse total shoulder replacement for the treatment of nonunion of a fracture of the proximal humerus. Using Checchia's classification, nine nonunions were type I, eight as type II, 12 as type III and six as type IV. The mean follow-up was 51 months (24 to 99). Post-operatively, the patients had a significant decrease in pain (p < 0.001), and a significant improvement in flexion, abduction, external rotation and Constant score (p < 0.001), but not in internal rotation. A total of nine complications were recorded in seven patients: six dislocations, one glenoid loosening in a patient who had previously suffered dislocation, one transitory paresis of the axillary nerve and one infection. Reverse total shoulder replacement may lead to a significant reduction in pain, improvement in function and a high degree of satisfaction. However, the rate of complications, particularly dislocation, was high. ©2014 The British Editorial Society of Bone & Joint Surgery.
Journal of Rehabilitation Research and Development.
1984-05-01
results of this study also port VA Contract V1O1(134)P-561, indicated that shoulder-effected position control of 1980 . prosthesis function has considerably...multiple axis artifi- cial arm control. J Biomech Eng 102:199-207, 1980 . 5. Simpson DC: The control and supply of a multimovement externally pow- ered...Above-elbow Prostheses. Final Re- port VA Contract V1O1(134)P-561, 1980 . 8. Carlson LE and Primmer KR: Ex- tended physiological proprioception for
Pompa, Giorgio; Di Carlo, Stefano; De Angelis, Francesca; Cristalli, Maria Paola; Annibali, Susanna
2015-01-01
This study assessed whether there are differences in marginal fit between laser-fusion and conventional techniques to produce fixed dental prostheses (FDPs). A master steel die with 2 abutments was produced to receive a posterior 4-unit FDPs and single copings. These experimental models were divided into three groups (n = 20/group) manufactured: group 1, Ni-Cr alloy, with a lost-wax casting technique; group 2, Co-Cr alloy, with selective laser melting (SLM); and group 3, yttria-tetragonal zirconia polycrystal (Y-TZP), with a milling system. All specimens were cut along the longitudinal axis and their adaptation was measured at the marginal and shoulder areas on the right and left sides of each abutment. Measurements were made using a stereomicroscope (×60 magnification) and a scanning electron microscope (×800 magnification). The data were analyzed using one-way analysis of variance and the Bonferroni post hoc test, with a significance cutoff of 5%. Significant differences (P < 0.05) were observed between group 3 and the other groups. The marginal opening was smallest with Co-Cr alloy substructures, while the shoulder opening was smallest with Ni-Cr alloy substructures. Within the limitations of this study, the marginal fit of an FDP is better with rapid prototyping (RP) via SLM than conventional manufacturing systems. PMID:26576419
Scapulohumeral rhythm in shoulders with reverse shoulder arthroplasty.
Walker, David; Matsuki, Keisuke; Struk, Aimee M; Wright, Thomas W; Banks, Scott A
2015-07-01
Little is known about kinematic function of reverse total shoulder arthroplasty (RTSA). Scapulohumeral rhythm (SHR) is a common metric for assessing muscle function and shoulder joint motion. The purpose of this study was to compare SHR in shoulders with RTSA to normal shoulders. Twenty-eight subjects, more than 12 months after unilateral RTSA, were recruited for an Institutional Review Board-approved study. Subjects performed arm abduction in the coronal plane with and without a 1.4-kg hand-held weight. Three-dimensional model-image registration techniques were used to measure orientation and position for the humerus and scapula from fluoroscopic images. Analysis of variance and Tukey tests were used to assess groupwise and pairwise differences. SHR in RTSA shoulders (1.3:1) was significantly lower than in normal shoulders (3:1). Below 30° abduction, RTSA and normal shoulders show a wide range of SHR (1.3:1 to 17:1). Above 30° abduction, SHR in RTSA shoulders was 1.3:1 for unweighted abduction and 1.3:1 for weighted abduction. Maximum RTSA shoulder abduction in weighted trials was lower than in unweighted trials. SHR variability in RTSA shoulders decreased with increasing arm elevation. RTSA shoulders show kinematics that are significantly different from normal shoulders. SHR in RTSA shoulders was significantly lower than in normal shoulders, indicating that RTSA shoulders use more scapulothoracic motion and less glenohumeral motion to elevate the arm. With these observations, it may be possible to improve rehabilitation protocols, with particular attention to the periscapular muscles, and implant design or placement to optimize functional outcomes in shoulders with RTSA. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Gigis, Ioannis; Nenopoulos, Alexandros; Giannekas, Dimitrios; Heikenfeld, Roderich; Beslikas, Theodoros; Hatzokos, Ippokratis
2017-01-01
Background: Proximal humeral fractures in elderly patients present with severe comminution and osteoporotic bone quality. Reverse shoulder arthroplasty has lately been proven beneficial in treating patients with complex proximal humeral fractures. The above technique is recommended and has better results in elderly than in younger individuals. Methods: We performed a literature search in the databases Pubmed, Medline, EMBASE and Cochrane Library for published articles between 1970 and 2016 using the terms: proximal humerus fractures and reverse shoulder arthroplasty. Results: Significant benefits with the use of reverse prosthesis, especially in patients older than 70 years with a proximal humeral fracture, include reduced rehabilitation time as well as conservation of a fixed fulcrum for deltoid action in case of rotator cuff failure. Compared with hemiarthroplasty and internal fixation, reverse prosthesis may be particularly useful and give superior outcomes in older patients, due to comminuted fractures in osteopenic bones. However, significant disadvantages of this technique are potential complications and a demanding learning curve.Therefore, trained surgeons should follow specific indications when applying the particular treatment of proximal humeral fractures and be familiar with the surgical technique. Conclusion: Although long-term results and randomized studies for reverse prosthesis are lacking, short and mid- term outcomes have given promising results encouraging more shoulder surgeons to use this type of prosthesis in proximal humeral fractures. PMID:28400879
Soft tissue balancing in total shoulder replacement.
Mueller, Maike; Hoy, Gregory
2014-03-01
Total shoulder arthroplasty is now capable of recreating near anatomic reproduction of native bony shoulder anatomy, but the function and longevity of anatomic shoulder replacement is dependent on a competent soft tissue envelope and adequate motoring of all musculo-tendinous units about the shoulder. Balancing the soft tissues requires understanding of the anatomy and pathology, as well as technical skills. The advent of reverse shoulder biomechanics has brought with it special requirements of understanding of the soft tissue elements still left in the shoulder despite major rotator cuff deficiency.
Humeral component retroversion in reverse total shoulder arthroplasty: a biomechanical study.
Gulotta, Lawrence V; Choi, Dan; Marinello, Patrick; Knutson, Zakary; Lipman, Joseph; Wright, Timothy; Cordasco, Frank A; Craig, Edward V; Warren, Russell F
2012-09-01
Reverse total shoulder arthroplasty offers pain relief and functional improvement for patients with rotator cuff-deficient shoulders. The purpose of this study was to determine the optimal amount of humeral retroversion for this prosthesis. Six cadaveric shoulders underwent computed tomography (CT) imaging and were then dissected of soft tissues, except for their tendinous attachments. A reverse total shoulder arthroplasty was implanted in 0°, 20°, 30°, and 40° of retroversion, and the shoulders were mounted on a simulator to determine the muscle forces required to achieve 30° and 60° of scaption. CT images were converted into 3-dimensional models, and the amount of internal and external rotation was determined with computer modeling at various scaption angles. No differences were found in the forces required for 30° or 60° of scaption for any muscle, at any retroversion. With increasing retroversion, more impingement-free external rotation was obtained, with a concomitant decrease in the amount of internal rotation. Above 60°, the humerus was allowed to rotate around the glenosphere unencumbered. Increasing retroversion did not affect the muscle force requirements for scaption across the shoulder. Placing the humeral component in 0° to 20° of retroversion allows maximum internal rotation with the arm at the side, a movement that is required for daily activities. This limits external rotation with the arm at the side, but has no effect on external rotation with the arm elevated. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Tiusanen, Hannu; Sarantsin, Pjotor; Stenholm, Miika; Mattie, Ryan; Saltychev, Mikhail
2016-07-01
To evaluate the trajectory of the change in range of motion after reverse shoulder joint replacement during 3-year follow-up among patients with rheumatoid arthritis. Retrospective cohort longitudinal study of 76 shoulder replacements performed in a university clinic. The range of shoulder motion was assessed by a physiotherapist using a manual goniometer with 5-degree precision before the surgery and 1, 3, 6, 12, and 36 months postoperatively. The shapes of the regression curves suggest that the improvement or decline observed in joint motion was happening mostly during the first year after surgery. After 1 year, the trajectories become flat and they remained unchanged until the end of follow-up. After shoulder joint replacement, the range of shoulder motion showed substantial changes during the first year only. This should be taken into account when scheduling control visits, planning rehabilitation, and predicting the use of community services after the surgery.
Hernández-Elena, J; de la Red-Gallego, M Á; Garcés-Zarzalejo, C; Pascual-Carra, M A; Pérez-Aguilar, M D; Rodríguez-López, T; Alfonso-Fernández, A; Pérez-Núñez, M I
2015-01-01
An analysis was made on relationship between Notching and functional and radiographic parameters after treatment of acute proximal humeral fractures with reverse total shoulder arthroplasty. A retrospective evaluation was performed on 37 patients with acute proximal humeral fracture treated by reversed shoulder arthroplasty. The mean follow-up was 24 months. Range of motion, intraoperative and postoperative complications were recorded. Nerot's classification was used to evaluate Notching. Patient satisfaction was evaluated with the Constant Score (CS). Statistical analysis was performed to evaluate the relationship between Notching and glenosphere position, or functional outcomes. Mean range of elevation, abduction, external and internal rotation were 106.22°, 104.46°, 46.08° and 40.27°, respectively. Mean CS was 63. Notching was present at 12 months in 29% of patients. Statistical analysis showed significance differences between age and CS, age and notching development, and tilt with notching. No statistical significance differences were found between elevation, abduction, internal and external rotation and CS either with scapular or glenosphere-neck angle. Reverse shoulder arthroplasty is a valuable option for acute humeral fractures in patients with osteoporosis and cuff-tear arthropathy. It leads to early pain relief and shoulder motion. Nevertheless, it is not exempt from complications, and long-term studies are needed to determine the importance of notching. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Morris, Brent J; Haigler, Richard E; Cochran, John M; Laughlin, Mitzi S; Elkousy, Hussein A; Gartsman, Gary M; Edwards, T Bradley
2016-01-01
The potential adverse effect of body mass index (BMI) on shoulder function scores after reverse shoulder arthroplasty (RSA) has not been investigated. We conducted a study to examine outcomes of RSA performed for rotator cuff tear arthropathy (RCTA) across BMI categories (normal weight, overweight, obese). We hypothesized that, compared with normal-weight patients, obese patients would have worse shoulder function scores, worse mobility, and more complications. Using a prospective shoulder arthroplasty registry, we identified 77 primary RSAs performed for RCTA with minimum 2-year follow-up. Thirty-four patients had normal weight (BMI <25 kg/m2), 21 were overweight (BMI 25-30 kg/m2), and 22 were obese (BMI >30 kg/m2). Shoulder function scores, mobility, and satisfaction were evaluated before surgery and at final follow-up. The 3 BMI groups were not significantly different on demographic factors, preoperative shoulder function scores, or preoperative mobility (P > .05). For each group, shoulder function scores and mobility significantly improved between the preoperative and final follow-up assessments (P < .001). Patient satisfaction was similar between groups (P = .967). Improved shoulder function scores, mobility, and patient satisfaction can be expected after RSA for RCTA in patients regardless of BMI.
NASA Astrophysics Data System (ADS)
Deng, Jie; Yao, Jun; Dewald, Julius P. A.
2005-12-01
In this paper, we attempt to determine a subject's intention of generating torque at the shoulder or elbow, two neighboring joints, using scalp electroencephalogram signals from 163 electrodes for a brain-computer interface (BCI) application. To achieve this goal, we have applied a time-frequency synthesized spatial patterns (TFSP) BCI algorithm with a presorting procedure. Using this method, we were able to achieve an average recognition rate of 89% in four healthy subjects, which is comparable to the highest rates reported in the literature but now for tasks with much closer spatial representations on the motor cortex. This result demonstrates, for the first time, that the TFSP BCI method can be applied to separate intentions between generating static shoulder versus elbow torque. Furthermore, in this study, the potential application of this BCI algorithm for brain-injured patients was tested in one chronic hemiparetic stroke subject. A recognition rate of 76% was obtained, suggesting that this BCI method can provide a potential control signal for neural prostheses or other movement coordination improving devices for patients following brain injury.
Kinematic analysis of dynamic shoulder motion in patients with reverse total shoulder arthroplasty.
Kwon, Young W; Pinto, Vivek J; Yoon, Jangwhon; Frankle, Mark A; Dunning, Page E; Sheikhzadeh, Ali
2012-09-01
Reverse total shoulder arthroplasty (rTSA) has been used to treat patients with irreparable rotator cuff dysfunction. Despite the proven clinical efficacy, there is minimal information regarding the underlying changes to the shoulder kinematics associated with this construct. Therefore, we sought to examine the kinematics of dynamic shoulder motion in patients with well-functioning rTSA. We tested 12 healthy subjects and 17 patients with rTSA. All rTSA patients were able to elevate their arms to at least 90° and received the implant as the primary arthroplasty at least 6 months before testing. On average, the rTSA patients elevated their arms to 112° ± 12° (mean ± SD) and reported an American Shoulder and Elbow Surgeons outcome score of 90.6 ± 6.3. A 3-dimensional electromagnetic motion capture device was used to detect the dynamic motion of the trunk, scapula, and humerus during bilateral active shoulder elevation along the sagittal, scapular, and coronal planes. In both healthy and rTSA shoulders, the majority of the humeral-thoracic motion was provided by the glenohumeral motion. Therefore, the ratio of glenohumeral to scapulothoracic (ST) motion was always greater than 1.62 during elevation along the scapular plane. In comparison to healthy subjects, however, the contribution of ST motion to overall shoulder motion was significantly increased in the rTSA shoulders. This increased contribution was noted in all planes of shoulder elevation and was maintained when weights were attached to the arm. Kinematics of the rTSA shoulders are significantly altered, and more ST motion is used to achieve shoulder elevation. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Cox, Ryan M; Padegimas, Eric M; Abboud, Joseph A; Getz, Charles L; Lazarus, Mark D; Ramsey, Matthew L; Williams, Gerald R; Horneff, John G
2018-06-01
It is common for patients to require staged bilateral shoulder arthroplasties. There is a unique cohort of patients who require an anatomic total shoulder arthroplasty (TSA) and a contralateral reverse shoulder arthroplasty (RSA). This study compared the outcomes of patients with a TSA in 1 shoulder and an RSA in the contralateral shoulder. Our institutional database was queried to identify all patients with a TSA and a contralateral RSA. Data collection included patient demographics, preoperative and latest follow-up shoulder range of motion, radiographic analysis, and postoperative complications. Identified patients were assessed at follow-up visits or contacted by phone for functional outcome scores. Nineteen patients met our inclusion/exclusion criteria. There was statistically significant greater internal rotation in the TSA shoulder (P= .044) but no significant difference in forward elevation (P = .573) or external rotation (P= .368). There was no radiographic evidence of humeral or glenoid component loosening of any arthroplasty implants. There were no significant differences between TSA and RSA shoulders for the American Shoulder and Elbow Surgeons Standardized Shoulder Assessment (P= .381), Simple Shoulder Test (P = .352), Single Assessment Numerical Evaluation (P = .709), and visual analog scale satisfaction (P= .448) or pain scores (P= .305). Thirteen patients (68.4%) preferred the RSA side, 1 patient (5.3%; z = 4.04, P < .001) patient preferred the TSA side, and 5 patients expressed no preference. Despite known limitations and differences between TSA and RSA designs, patients who have received both implants are highly satisfied with both. The only parameter in which the TSA had superior outcomes was internal rotation. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Walker, David R; Kinney, Allison L; Wright, Thomas W; Banks, Scott A
2016-06-01
Reverse total shoulder arthroplasty commonly treats cuff-deficient or osteoarthritic shoulders not amenable to rotator cuff repair. This study investigates deltoid moment arm sensitivity to variations in the joint center and humeral offset of 3 representative reverse total shoulder arthroplasty subjects. We hypothesized that a superior joint implant placement may exist, indicated by muscle moment arms, compared with the current actual surgical implant configuration. Moment arms for the anterior, lateral, and posterior aspects of the deltoid muscle were determined for 1521 perturbations of the humeral offset location away from the surgical placement in a subject-specific musculoskeletal model with motion defined by subject-specific in vivo abduction kinematics. The humeral offset was varied from its surgical position ±4 mm in the anterior/posterior direction, ±12 mm in the medial/lateral direction, and -10 to 14 mm in the superior/inferior direction. The anterior deltoid moment arm varied in humeral offset and center of rotation up to 20 mm, primarily in the medial/lateral and superior/inferior directions. The lateral deltoid moment arm varied in humeral offset up to 20 mm, primarily in the medial/lateral and anterior/posterior directions. The posterior deltoid moment arm varied up to 15 mm, primarily in early abduction, and was most sensitive to humeral offset changes in the superior/inferior direction. High variations in muscle moment arms were found for all 3 deltoid components, presenting an opportunity to dramatically change the deltoid moment arms through surgical placement of the reverse shoulder components and by varying the overall offset of the humerus. Basic Science Study; Computer Modeling. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Lee, Kwang Won; Kim, Yong In; Kim, Ha Yong; Yang, Dae Suk; Lee, Gyu Sang; Choy, Won Sik
2016-09-01
There have been few reports on altered kinematics of the shoulder after reverse total shoulder arthroplasty (RTSA). We investigated differences in 3-dimensional (3D) scapular motions assessed using an optical tracking system between RTSA treated shoulders and asymptomatic contralateral shoulders during arm motion. Thirteen patients who underwent RTSA were assessed for active arm elevation in 2 distinct elevation planes (sagittal plane flexion and scapular plane abduction). Their mean age was 72 years (range, 69 to 79 years) and the mean follow-up was 24.4 months (range, 13 to 48 months). The dominant side was the right side in all the 13 patients, and it was also the side treated with RTSA. Scapular kinematics was recorded with an optical tracking system. The scapular kinematics and the scapulohumeral rhythm (SHR) of the RTSA shoulders and asymptomatic contralateral shoulders were recorded and analyzed during arm elevation. There were no significant differences in internal/external rotation and anterior/posterior tilting of the scapula between shoulders during arm motion (p > 0.05). However, upward rotation of the scapula differed significantly during arm motion (p = 0.035 for sagittal plane flexion; p = 0.046 for scapular plane abduction). There were significant differences in the SHR between the two shoulders (p = 0.016 for sagittal plane flexion; p = 0.021 for scapular plane abduction). The shoulder kinematics after RTSA showed significant differences from the contralateral asymptomatic shoulders. Increased upward rotation and decreased SHR after RTSA indicate that RTSA shoulders use more scapulothoracic motion and less glenohumeral motion to elevate the arm.
Lee, Kwang Won; Kim, Ha Yong; Yang, Dae Suk; Lee, Gyu Sang; Choy, Won Sik
2016-01-01
Background There have been few reports on altered kinematics of the shoulder after reverse total shoulder arthroplasty (RTSA). We investigated differences in 3-dimensional (3D) scapular motions assessed using an optical tracking system between RTSA treated shoulders and asymptomatic contralateral shoulders during arm motion. Methods Thirteen patients who underwent RTSA were assessed for active arm elevation in 2 distinct elevation planes (sagittal plane flexion and scapular plane abduction). Their mean age was 72 years (range, 69 to 79 years) and the mean follow-up was 24.4 months (range, 13 to 48 months). The dominant side was the right side in all the 13 patients, and it was also the side treated with RTSA. Scapular kinematics was recorded with an optical tracking system. The scapular kinematics and the scapulohumeral rhythm (SHR) of the RTSA shoulders and asymptomatic contralateral shoulders were recorded and analyzed during arm elevation. Results There were no significant differences in internal/external rotation and anterior/posterior tilting of the scapula between shoulders during arm motion (p > 0.05). However, upward rotation of the scapula differed significantly during arm motion (p = 0.035 for sagittal plane flexion; p = 0.046 for scapular plane abduction). There were significant differences in the SHR between the two shoulders (p = 0.016 for sagittal plane flexion; p = 0.021 for scapular plane abduction). Conclusions The shoulder kinematics after RTSA showed significant differences from the contralateral asymptomatic shoulders. Increased upward rotation and decreased SHR after RTSA indicate that RTSA shoulders use more scapulothoracic motion and less glenohumeral motion to elevate the arm. PMID:27583116
Achieving fixation in glenoids with superior wear using reverse shoulder arthroplasty.
Roche, Christopher P; Stroud, Nicholas J; Martin, Brian L; Steiler, Cindy A; Flurin, Pierre-Henri; Wright, Thomas W; Zuckerman, Joseph D; Dipaola, Matthew J
2013-12-01
Superior glenoid wear is a common challenge with reverse shoulder arthroplasty and, if left uncorrected, can result in superior glenoid tilt, which increases the risk of aseptic glenoid loosening. This study evaluates the impact of an E2 superior defect on reverse shoulder glenoid fixation in composite scapulae after correction of glenoid tilt by use of 2 different glenoid reaming techniques: eccentric reaming and off-axis reaming. A superior glenoid defect was created in 14 composite scapulae. The superior defect was corrected by 2 different glenoid reaming techniques: (1) eccentric reaming with implantation of a standard glenoid baseplate and (2) off-axis reaming with implantation of a superior-augment glenoid baseplate. Each corrected superior-defect scapula was then cyclically loaded (along with a control group consisting of 7 non-worn scapulae) for 10,000 cycles at 750 N; glenoid baseplate displacement was measured for each group to quantify fixation before and after cyclic loading. Regardless of the glenoid reaming technique or the glenoid baseplate type, each standard and superior-augment glenoid baseplate remained well fixed in this superior-defect model scenario after cyclic loading. No differences in baseplate displacement were observed either before or after cyclic loading between groups. Our results suggest that either glenoid reaming technique may be used to achieve fixation in the clinically challenging situation of superior wear with reverse shoulder arthroplasty. Basic science, biomechanical study. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Grubhofer, Florian; Wieser, Karl; Meyer, Dominik C; Catanzaro, Sabrina; Beeler, Silvan; Riede, Ulf; Gerber, Christian
2016-10-01
Anatomic reduction and stable internal fixation of complex proximal humeral fractures in the elderly is challenging. Secondary displacement, screw perforation, and humeral head necrosis are common complications. The outcome of hemiarthroplasty is unpredictable and strongly dependent on the uncertain healing of the greater tuberosity. This multicenter study retrospectively analyzes the midterm results of primary reverse total shoulder arthroplasty for the treatment of acute, complex fractures of the humerus in an elderly population. Fifty-two shoulders in 51 patients with a mean age of 77 years treated with reverse total shoulder arthroplasty for an acute, complex fracture of the proximal humerus were clinically and radiographically analyzed after a mean follow-up period of 35 months (range, 12-90 months). There were no intraoperative complications. Revision surgery was performed in 4 shoulders. At final follow-up, the absolute and relative Constant scores averaged 62 points (range, 21-83 points) and 86% (range, 30%-100%), respectively, with a mean Subjective Shoulder Value of 83% (range, 30%-100%). Of the patients, 92% rated the treatment outcome as excellent or good. Patients with a resected or secondarily displaced greater tuberosity had an inferior clinical outcome to those with a healed greater tuberosity. The midterm clinical results are predictably good, with low complication rates and a rapid postoperative recovery of painfree everyday function. If secondary displacement of the greater tuberosity occurs, revision surgery may warrant consideration in view of potential improvement of ultimate outcome. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Functional outcomes after shoulder resection: the patient's perspective.
Stevens, Nicole M; Kim, H Mike; Armstrong, April D
2015-09-01
Resection arthroplasty is a salvage procedure used for the treatment of deep-seated infections after total shoulder arthroplasty, hemiarthroplasty, and reverse total shoulder arthroplasty. Previous studies have reported a 50% to 66% rate of pain relief after resection arthroplasty but with significant functional limitations. Our study aimed to qualify the perspective of the patients on their limitations and satisfaction with resection arthroplasty. A retrospective record review of resection arthroplasties performed between September 2003 and December 2012 yielded 14 patients, and 7 completed the survey. The patients completed surveys with the focus on the "patient perspective." Functional scores, including American Shoulder and Elbow Surgeons, Simple Shoulder Test, Disabilities of the Arm, Shoulder, and Hand (DASH), DASH work, and DASH sports, were determined. Pain reduction and functional outcomes were similar to past reports of resection arthroplasty. Five of the 7 patients (71%) reported satisfaction with their resection arthroplasty, and 6 of the 7 patients (86%) would undergo the procedure again if given the choice. Five of the 7 patients (71%) were able to most of activities of daily living. Patients in our study were generally satisfied with their resection arthroplasty. Resection arthroplasty is a reasonable option for treatment of deep-seated periprosthetic infections or for patients with multiple previous failed procedures for total shoulder arthroplasty, hemiarthroplasty. and reverse shoulder arthroplasty. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Skedros, John G.; Keenan, Kendra E.; Updike, Wanda S.; Oliver, Marquam R.
2014-01-01
This report describes a 58-year-old insulin-dependent diabetic male patient who initially sustained a proximal humerus fracture from a fall. The fracture fixation failed and then was converted to a humeral hemiarthroplasty, which became infected with Candida glabrata and Serratia marcescens. After these infections were believed to be cured with antibacterial and antifungal treatments and two-stage irrigation and debridement, he underwent conversion to a reverse total shoulder arthroplasty. Unfortunately, the C. glabrata infection recurred and, nearly 1.5 years after implantation of the reverse total shoulder, he had a resection arthroplasty (removal of all implants and cement). His surgical and pharmacologic treatment concluded with (1) placement of a tobramycin-impregnated cement spacer also loaded with amphotericin B, with no plan for revision arthroplasty (i.e., the spacer was chronically retained), and (2) chronic use of daily oral fluconazole. We located only three reported cases of Candida species causing infection in shoulder arthroplasties (two C. albicans, one C. parapsilosis). To our knowledge, a total shoulder arthroplasty infected with C. glabrata has not been reported, nor has a case of a C. glabrata and S. marcescens periprosthetic coinfection in any joint. In addition, it is well known that S. marcescens infections are uncommon in periprosthetic joint infections. PMID:25431708
Graves, Stephen; Sedrakyan, Art; Baste, Valborg; Gioe, Terence J; Namba, Robert; Martínez Cruz, Olga; Stea, Susanna; Paxton, Elizabeth; Banerjee, Samprit; Isaacs, Abby J; Robertsson, Otto
2014-12-17
Posterior-stabilized total knee prostheses were introduced to address instability secondary to loss of posterior cruciate ligament function, and they have either fixed or mobile bearings. Mobile bearings were developed to improve the function and longevity of total knee prostheses. In this study, the International Consortium of Orthopaedic Registries used a distributed health data network to study a large cohort of posterior-stabilized prostheses to determine if the outcome of a posterior-stabilized total knee prosthesis differs depending on whether it has a fixed or mobile-bearing design. Aggregated registry data were collected with a distributed health data network that was developed by the International Consortium of Orthopaedic Registries to reduce barriers to participation (e.g., security, proprietary, legal, and privacy issues) that have the potential to occur with the alternate centralized data warehouse approach. A distributed health data network is a decentralized model that allows secure storage and analysis of data from different registries. Each registry provided data on mobile and fixed-bearing posterior-stabilized prostheses implanted between 2001 and 2010. Only prostheses associated with primary total knee arthroplasties performed for the treatment of osteoarthritis were included. Prostheses with all types of fixation were included except for those with the rarely used reverse hybrid (cementless tibial and cemented femoral components) fixation. The use of patellar resurfacing was reported. The outcome of interest was time to first revision (for any reason). Multivariate meta-analysis was performed with linear mixed models with survival probability as the unit of analysis. This study includes 137,616 posterior-stabilized knee prostheses; 62% were in female patients, and 17.6% had a mobile bearing. The results of the fixed-effects model indicate that in the first year the mobile-bearing posterior-stabilized prostheses had a significantly higher hazard ratio (1.86) than did the fixed-bearing posterior-stabilized prostheses (95% confidence interval, 1.28 to 2.7; p = 0.001). For all other time intervals, the mobile-bearing posterior-stabilized prostheses had higher hazard ratios; however, these differences were not significant. Mobile-bearing posterior-stabilized prostheses had an increased rate of revision compared with fixed-bearing posterior-stabilized prostheses. This difference was evident in the first year. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Masjedi, Milad; Lovell, Cara; Johnson, Garth R
2011-12-01
Patients with rotator cuff tear and degenerative shoulder joint disease commonly experience severe pain and reduced performance during activities of daily living. A popular way to treat these patients is by means of reverse anatomy shoulder prosthesis. Studying the kinematics of subjects with reverse anatomy implant would be useful in order to gain knowledge about functionality of different designs. It is hypothesized that the kinematics of these subjects, in the absence of rotator cuff muscles, differs from that of normal subjects. In this study the upper limb kinematics of 12 subjects with a Bayley-Walker reverse anatomy shoulder prosthesis while performing tasks common in everyday activities and those that represent the range of motion was analyzed and compared to that of 12 normal subjects. Each patient also completed an Oxford Shoulder Score. Substantial reduction in the Bayley-Walker subjects' ranges of motion was observed compared to normal subjects. The mean abduction angle decreased from 109° (±20) for normal subjects to 64° (±25). A similar trend was observed during flexion and axial rotation tasks. Furthermore, the normal group showed less variable ranges of motion performing the standard tasks, whereas for the prosthetic group this varied greatly, which is likely to be dependent on muscle strength. Although the decreased range of motion was prominent, subjects were able to complete most of the tasks by compensating with their elbow and trunk. The most challenging task for Bayley-Walker subjects was lifting an object to head height. Copyright © 2010 Elsevier B.V. All rights reserved.
Revision shoulder arthroplasty from resurfacing to non-cemented short-stem reverse prosthesis.
Natera, L; Bruguera, J; Atoun, E; Levy, O
2016-01-01
To assess the surgical parameters and the clinical and radiological outcomes of revisions of resurfacing shoulder arthroplasty to non-cemented short-stem reverse total shoulder arthroplasty. A total of 23 revisions from resurfacing shoulder arthroplasty to reverse total shoulder arthroplasty were performed. The mean age was 70.3±11.95 years. The patients included 82.6% (19/23) revised for cuff failure; 13.04% (3/23) cuff failure and aseptic loosening, and 4.35% (1/23) peri-prosthetic fracture. The need for humeral osteotomy or structural allograft, operation length, blood loss, blood transfusions and intraoperative fractures were recorded. Minimum follow-up 25 months. No humeral osteotomy or humeral structural allograft was required, and 2/23 (8.69%) required allograft for glenoid reconstruction. The mean operation time was 113.35±21.30minutes. Intra-operative blood loss was 374±245.09 mls. Blood transfusion was required in one case. Intra-operative fracture occurred in 1 case. The Constant score improved from 17.32 to 59.78 (age/sex adjusted, 84). Overall satisfaction improved from 1.37 to 8.04. The range of motion increased 79.57° in forward elevation; 72.88° in abduction; 38.06° in internal rotation; and 13.57° in external rotation. There was no evidence of radiolucency, subsidence, or bone resorption. Revisions of resurfacing implants to non-cemented short-stem reverse prosthesis show good clinical and radiological outcomes, with minimal intra-operative complexities. IV, case series. Copyright © 2016 SECOT. Published by Elsevier Espana. All rights reserved.
Gutiérrez, Sergio; Greiwe, R Michael; Frankle, Mark A; Siegal, Steven; Lee, William E
2007-01-01
There has been renewed interest in reverse shoulder arthroplasty for the treatment of glenohumeral arthritis with concomitant rotator cuff deficiency. Failure of the prosthesis at the glenoid attachment site remains a concern. The purpose of this study was to examine glenoid component stability with regard to the angle of implantation. This investigation entailed a biomechanical analysis to evaluate forces and micromotion in glenoid components attached to 12 polyurethane blocks at -15 degrees, 0 degrees, and +15 degrees of superior and inferior tilt. The 15 degrees inferior tilt had the most uniform compressive forces and the least amount of tensile forces and micromotion when compared with the 0 degrees and 15 degrees superiorly tilted baseplate. Our results suggest that implantation with an inferior tilt will reduce the incidence of mechanical failure of the glenoid component in a reverse shoulder prosthesis.
Kurowicki, Jennifer; Triplet, Jacob J; Momoh, Enesi; Moor, Molly A; Levy, Jonathan C
2016-12-01
Locked anterior shoulder (LAS) with static instability and anterior glenoid bone loss is challenging in the elderly population. Reverse shoulder arthroplasty (RSA) has been employed in treating these patients. No study has compared RSA for LAS with classically indicated RSA. A retrospective case-control study of patients treated with RSA for LAS with glenoid bone loss and static instability was performed using matched controls treated with primary RSA for classic indications. Twenty-four cases and 48 controls were evaluated. Average follow-up was 25.5 months, and median age was 76 years. Motion, outcome assessments, and postoperative radiographs were compared. Preoperatively, LAS had significantly less rotation and lower baseline outcome scores. Glenoid bone grafting was more common (P = .05) in the control group (26%) than in the LAS group (6.3%). Larger glenospheres were used more often (P = .001) in the LAS group (75%) than in the control group (29%). Both groups demonstrated significant improvements in pain, function, and outcome scores. Postoperatively, the control group had significantly better elevation and functional outcome scores. With the exception of flexion and Simple Shoulder Test score, effectiveness of treatment was similar between groups. Postoperative acromion stress fractures were seen in 21% of LAS patients and 9% of controls (P = .023) with a predominance of type 3 fractures in LAS. Two LAS patients remained dislocated. Patients with LAS treated with RSA can anticipate improvements in pain and function by use of larger glenospheres, often without the need for glenoid bone grafting. Worse postoperative motion and function and a higher incidence of acromion stress fracture may be expected. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Accuracy of patient-specific guided glenoid baseplate positioning for reverse shoulder arthroplasty.
Levy, Jonathan C; Everding, Nathan G; Frankle, Mark A; Keppler, Louis J
2014-10-01
The accuracy of reproducing a surgical plan during shoulder arthroplasty is improved by computer assistance. Intraoperative navigation, however, is challenged by increased surgical time and additional technically difficult steps. Patient-matched instrumentation has the potential to reproduce a similar degree of accuracy without the need for additional surgical steps. The purpose of this study was to examine the accuracy of patient-specific planning and a patient-specific drill guide for glenoid baseplate placement in reverse shoulder arthroplasty. A patient-specific glenoid baseplate drill guide for reverse shoulder arthroplasty was produced for 14 cadaveric shoulders based on a plan developed by a virtual preoperative 3-dimensional planning system using thin-cut computed tomography images. Using this patient-specific guide, high-volume shoulder surgeons exposed the glenoid through a deltopectoral approach and drilled the bicortical pathway defined by the guide. The trajectory of the drill path was compared with the virtual preoperative planned position using similar thin-cut computed tomography images to define accuracy. The drill pathway defined by the patient-matched guide was found to be highly accurate when compared with the preoperative surgical plan. The translational accuracy was 1.2 ± 0.7 mm. The accuracy of inferior tilt was 1.2° ± 1.2°. The accuracy of glenoid version was 2.6° ± 1.7°. The use of patient-specific glenoid baseplate guides is highly accurate in reproducing a virtual 3-dimensional preoperative plan. This technique delivers the accuracy observed using computerized navigation without any additional surgical steps or technical challenges. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Reverse Shoulder Arthroplasty Prosthesis Design Classification System.
Routman, Howard D; Flurin, Pierre-Henri; Wright, Thomas W; Zuckerman, Joseph D; Hamilton, Matthew A; Roche, Christopher P
2015-12-01
Multiple different reverse total shoulder arthroplasty (rTSA) prosthesis designs are available in the global marketplace for surgeons to perform this growing procedure. Subtle differences in rTSA prosthesis design parameters have been shown to have significant biomechanical impact and clinical consequences. We propose an rTSA prosthesis design classification system to objectively identify and categorize different designs based upon their specific glenoid and humeral prosthetic characteristics for the purpose of standardizing nomenclature that will help the orthopaedic surgeon determine which combination of design configurations best suit a given clinical scenario. The impact of each prosthesis classification type on shoulder muscle length and deltoid wrapping are also described to illustrate how each prosthesis classification type impacts these biomechanical parameters.
Dedy, Nicolas J; Gouk, Conor J; Taylor, Fraser J; Thomas, Michael; Tan, S L Ezekiel
2018-06-01
The deltopectoral approach for reverse shoulder arthroplasty (RSA) requires subscapularis tenotomy or lesser tuberosity osteotomy. Whether the subscapularis should be repaired at the conclusion of the procedure remains controversial. The present study sonographically assessed the subscapularis after RSA and evaluated the effect of tendon integrity on functional outcome. All patients who had undergone RSA in the Gold Coast University Hospital between 2005 and 2016 were included. Sonography was performed by a blinded examiner. Function was assessed using the Disabilities of the Arm, Shoulder and Hand, the Constant-Murley, and Oxford Shoulder scores. Internal rotation ability was recorded on a 6-point scale. The study included 43 patients (48 shoulders). Median length of follow-up was 19 months (range, 4-132 months). On sonography, the subscapularis was graded intact in 6 shoulders (13%), intact with mild attenuation in 16 (33%), severely attenuated in 15 (31%), and not intact or absent in 11 (23%). Differences in Disabilities of the Arm, Shoulder and Hand, Constant-Murley, or Oxford Shoulder scores between intact and attenuated or absent subscapularis shoulders were not significant. Internal rotation scores were significantly higher in the intact and mildly attenuated tendon group than in the absent tendon group (U = 1.0, P = .001 and U = 28.5, P = .007, respectively). The present work is the first long-term outcome study of RSA using sonography to assess the subscapularis. Subscapularis integrity did not appear to have a measurable effect on patient outcome as measured by standard scores but was important for internal rotation ability after RSA. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.
Stübig, Timo; Petri, Maximilian; Zeckey, Christian; Hawi, Nael; Krettek, Christian; Citak, Musa; Meller, Rupert
2013-12-01
Reversed shoulder arthroplasty is an alternative to total shoulder arthroplasty for various indications. The long-term results depend on stable bone fixation, and correct positioning of the glenoid component. The potential contribution of image guidance for reversed shoulder arthroplasty procedures was tested in vitro. 27 positioning procedures (15 navigated, 12 non-navigated) of the glenoid baseplate in reverse shoulder arthroplasty were performed by a single experienced orthopaedic surgeon. A Kirschner wire was placed freehand or with the use of a navigated drill guide. For the navigated procedures, a flat detector 3D C-arm with navigation system was used. The Kirschner wire was to be inserted 12 mm from the inferior glenoid, with an inferior tilt of 10° and centrally in the axial scapular axis. The insertion point in the glenoid as well as the position of the K-wire in the axial and sagittal planes were measured. For statistical analysis, t-tests were performed with a significance level of 0.05. The inferior glenoid drilling distance was 14.1 ± 3.4 mm for conventional placement and 15.1 ± 3.4 mm for the navigated procedure (P = 0.19). The inferior tilt showed no significant difference between the two methods (conventional 7.4 ± 5.2°, navigated 7.7 ± 4.9°, P = 0.63). The glenoid version in the axial plane showed significantly higher accuracy for the navigated procedure, with a mean deviation of 1.6 ±4.5° for the navigated procedure compared with 11.5 ± 6.5° for the conventional procedure(P = 0.004). Accurate positioning of the glenoidal baseplate in the axial scapular plane can be improved using 3D C-arm navigation for reversed shoulder arthroplasty. However, computer navigation may not improve the inferior tilt of the component or the position in the inferior glenoid to avoid scapular notching. Nevertheless, further studies are required to confirm these findings in the clinical setup. Copyright © 2013 John Wiley & Sons, Ltd.
Reverse total shoulder arthroplasty
Familiari, Filippo; Rojas, Jorge; Nedim Doral, Mahmut; Huri, Gazi; McFarland, Edward G.
2018-01-01
Since the introduction of reverse total shoulder arthroplasty (RTSA) in 1987 (in Europe) and 2004 (in the United States), the number of RTSAs performed annually has increased. Although the main indication for RTSA has been rotator cuff tears, indications have expanded to include several shoulder conditions, many of which involve dysfunction of the rotator cuff. RTSA complications have been reported to affect 19% to 68% of patients and include acromial fracture, haematoma, infection, instability, mechanical baseplate failure, neurological injury, periprosthetic fracture and scapular notching. Current controversies in RTSA include optimal baseplate positioning, humeral neck-shaft angle (135° versus 155°), glenosphere placement (medial, lateral or bony increased offset RTSA) and subscapularis repair. Improvements in prosthesis design, surgeon experience and clinical results will need to occur to optimize this treatment for many shoulder conditions. Cite this article: EFORT Open Rev 2018;3:58–69 DOI: 10.1302/2058-5241.3.170044 PMID:29657846
Trouilloud, P; Gonzalvez, M; Martz, P; Charles, H; Handelberg, F; Nyffeler, R W; Baulot, E
2014-05-01
We describe our experience with a new system of patient-specific template called Personal Fit(®), which is unique in shoulder surgery and used in combination with Duocentric(®) prosthesis. The reverse prosthesis's concept is the invention of Paul Grammont, developed with Grammont's team of Dijon University as from 1981, which led to the first reversed total shoulder prosthesis called Trumpet in 1985. The Duocentric(®) prosthesis developed in 2001 is the third-generation prosthesis, coming from the Trumpet and the second-generation prosthesis Delta(®) (DePuy). This prosthesis provides a novel solution to the notching problem with an inferior overhang integrated onto the glenoid baseplate. Personal Fit(®) system is based on reconstructing the shoulder joint bones in three dimensions using CT scan data, placing a landmark on the scapula and locating points on the glenoid and humerus. That will be used as a reference for the patient-specific templates. We study the glenoid position planned with Personal Fit(®) software relative to native glenoid position in 30 cases. On average, the difference between the planned retroversion (or anteversion in one case) and native retroversion was 8.6°.
Cuff, Derek J; Pupello, Derek R; Santoni, Brandon G; Clark, Rachel E; Frankle, Mark A
2017-11-15
We previously evaluated 94 patients (96 shoulders) who underwent reverse shoulder arthroplasty using a central compressive screw with 5.0-mm peripheral locking screws for baseplate fixation and a center of rotation lateral to the glenoid as treatment for end-stage rotator cuff deficiency. The purpose of this study was to report updated results at a minimum follow-up of 10 years. Forty patients (42 shoulders) were available for clinical follow-up. In the patients available for study, implant survivorship, with the end point being revision for any reason, was 90.7%. Since our 5-year report, 2 patients underwent revision surgery; 1 patient sustained a periprosthetic fracture 7 years postoperatively and 1 patient had a dislocation because of chronic shoulder instability at 8 years postoperatively. At a minimum follow-up of 10 years, the patients continued to maintain their improved outcome scores and range of motion, which were comparable with earlier follow-up evaluations. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Prieto-Borja, Laura; Rodriguez-Sevilla, Graciela; Auñon, Alvaro; Pérez-Jorge, Concepción; Sandoval, Enrique; Garcia-Cañete, Joaquín; Gadea, Ignacio; Fernandez-Roblas, Ricardo; Blanco, Antonio; Esteban, Jaime
2017-04-01
The development of sonication protocols over the last few years has improved the sensitivity of conventional cultures for the diagnosis of prosthetic-joint infection (PJI). However, the development of a new, specifically designed kit for the molecular diagnosis of PJI could provide a major improvement in this field. Prostheses retrieved from patients who underwent implant removal from May 2014 to May 2015 were sent for culture, and processed according to a previously defined protocol that included sonication. Furthermore, 180 microlitres of sonication fluid were used to carry out the multiplex PCR test (Unyvero i60 system ® ). A comparison of the sensitivity, specificity, positive (PPV) and negative (NPV) predictive value, was performed. The study was approved by the Clinical Research Ethics Committee. The analysis included 88 prostheses from 68 patients (1.29 prostheses/patient). The type of prostheses studied were knee (n=55), total hip (n=26), partial hip (n=5), and shoulder (n=2). Twenty-nine patients were diagnosed with a PJI (15 delayed, 12 acute, and 2 haematogenous infections). In 24 cases, the result of the PCR was positive, all but 1 corresponding to patients with clinical criteria of PJI. Nine resistance mechanisms were detected from 5 samples. The Unyvero i60 system ® showed slightly better results than traditional culture in terms of specificity and PPV. The Unyvero i60 system ® may play a role in rapid diagnosis of PJI, due to its high specificity and PPV. However, despite these results, cultures have to be performed to detect organisms not detected by the system. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Reverse shoulder arthroplasty in patients with os acromiale.
Aibinder, William R; Schoch, Bradley S; Cofield, Robert H; Sperling, John W; Sánchez-Sotelo, Joaquin
2017-09-01
Os acromiale has been reported in up to 15% of the general population. Reverse total shoulder arthroplasty (RTSA) increases deltoid tension, which could potentially lead to excessive stress on a pre-existent os acromiale. The purpose of this study was to determine the outcome and complications of primary RTSA in patients with radiographic evidence of an os acromiale. Between 2005 and 2013, 25 shoulders underwent primary RTSA with an associated os acromiale, which was classified preacromion (3), mesoacromion (20), and meta-acromion (2). All patients were observed for a minimum of 2 years or until reoperation. Mean follow-up time was 30.8 (range, 1-81.4) months. Outcomes included pain scores, range of motion, patient satisfaction, American Shoulder and Elbow Surgeons scores, and radiographic outcomes. RTSA led to an improvement in pain scores in 24 of 25 shoulders. Mean elevation, external rotation, and internal rotation were improved at final follow-up (124°, 46°, and L4, respectively). Three patients required reoperation, including revision surgery for dislocation (2) and excision of a painful os acromiale (1). Postoperative tilting of the os acromiale was noted in 7 shoulders (28%). There was no statistically significant difference in any outcome measures between shoulders with and shoulders without postoperative tilt of the os acromiale. The outcome of RTSA does not seem to be negatively affected by the presence of an os acromiale. Pain around an os acromiale after RTSA is rare. Inferior tilting is observed in approximately one-third of the shoulders after RTSA and does not seem to change the overall outcome. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
[Modelling metallic bars in an orthopaedic laboratory: postural and biomechanical analysis].
Draicchio, F; Miccio, A; Mari, S; Silvetti, A; Forzano, F; Ranavolo, A
2012-01-01
Aim of this work is to assess, with an objective technique (i.e. surface electromyography), the upper limb biomechanical load in workers specialized in manufacturing of orthopedic prostheses. We considered two different working configurations (workstation height at 105 and 110 cm) and three different materials to be modeled (aluminum, steel and titanium). Our results showed significant differences between aluminum/steel and titanium bars. As regards the working configurations, we found differences in the muscle activation patterns between the two heights, with an increased exertion of the shoulder muscles at 110 cm with respect to 105.
Denard, Patrick J; Lädermann, Alexandre; Brady, Paul C; Narbona, Pablo; Adams, Christopher R; Arrigoni, Paolo; Huberty, Dave; Zlatkin, Michael B; Sanders, Timothy G; Burkhart, Stephen S
2015-10-01
Pseudoparalysis is defined as active forward flexion less than 90° with full passive motion. There is controversy about the ideal surgical management of a massive rotator cuff tear with pseudoparalysis. The purpose of this study was to prospectively analyze the ability to reverse pseudoparalysis with an arthroscopic rotator cuff repair (ARCR). The hypothesis was that in the absence of substantial glenohumeral arthritis, preoperative fatty infiltration of grade 3 or higher and an acromiohumeral interval (AHI) of less than 7 mm would not prevent reversal of pseudoparalysis with an ARCR. Case series; Level of evidence, 4. A prospective multicenter study of ARCR performed for preoperative pseudoparalysis was conducted. The minimum follow-up was 1 year. The mean patient age was 63 years, and pseudoparalysis was present for a mean of 4.2 months preoperatively. Preoperative radiographic evaluation included plain film evaluation of the AHI and Hamada classification and MRI evaluation of fatty degeneration and rotator cuff retraction. Functional outcome was determined by the Simple Shoulder Test (SST), American Shoulder and Elbow Surgeons (ASES) Shoulder Score, visual analog scale (VAS), and subjective shoulder value (SSV). Of the 58 patients enrolled, 56 had at least 1 year of follow-up. Mean active forward flexion improved from 47° preoperatively to 159° postoperatively (P < .001). Statistically significant improvements were seen in the SST (from 2.8 preoperatively to 10.1 postoperatively), SSV (from 28 to 83), ASES Shoulder Score (from 37 to 88), and VAS (from 5.7 to 1.1) (P < .001). Pseudoparalysis was reversed in 53 of 56 patients (95%). There was no difference in the rate of reversal of pseudoparalysis between those patients with an AHI of less than 7 mm (88.2%) and those with an AHI of 7 mm or more (96.9%) (P =.289). Pseudoparalysis was reversed in all 8 of the patients with fatty degeneration of grade 3 or higher in 1 or more of the rotator cuff muscles. ARCR can lead to reversal of preoperative pseudoparalysis in patients with minimal preoperative glenohumeral arthritis. ARCR is a viable first line of treatment for patients with pseudoparalysis in the absence of advanced glenohumeral arthritis. © 2015 The Author(s).
[Cuff tear arthropathy – long-term results of reverse total shoulder arthroplasty].
Brunner, U; Rückl, K; Fruth, M
2013-07-01
The results after reverse total shoulder arthroplasty for cuff tear arthropathy are superior and the complications fewer than for other etiologies, such as rheumatoid arthritis, fracture, fracture sequelae or even revision. The improvements in function and pain are excellent whereas rotation may be unaffected. Revisions and complications can be encountered in the first 3 years and the survival curve of the prosthesis is still good after 10 years with 90%. Progressive functional and radiological deterioration is observed after 9 years in approximately 30% of the patients without apparent problems with the prosthesis. Notching is progressive with incidence and size over time, without a proven correlation to the functional results but remains a major concern. Modification of the implants, the operative techniques and experience could significantly improve the results and reduce the rate of complications. Lateralization of the center of rotation and smaller inclination angles have a positive effect on the rate of notching and the range of motion, especially for the rotation. New prosthetic designs and operative techniques attempt to implement a combination of the biomechanical improvements. Reverse shoulder arthroplasty remains a challenging operation with a high rate of complications. The results depend on the etiology and the function of the remaining muscles and therefore on the experience and the skill of the surgeon to implement the appropriate biomechanical factors. Because of the concerns regarding the longevity, reverse shoulder arthroplasty should be reserved for the elderly over 70 years of age.
Alkaduhimi, Hassanin; van den Bekerom, Michel P J; van Deurzen, Derek F P
2017-06-01
Posterior shoulder dislocations are accompanied by high forces and can result in an anteromedial humeral head impression fracture called a reverse Hill-Sachs lesion. This reverse Hill-Sachs lesion can result in serious complications including posttraumatic osteoarthritis, posterior dislocations, osteonecrosis, persistent joint stiffness, and loss of shoulder function. Treatment is challenging and depends on the amount of bone loss. Several techniques have been reported to describe the surgical treatment of lesions larger than 20%. However, there is still limited evidence with regard to the optimal procedure. Favorable results have been reported by performing segmental reconstruction of the reverse Hill-Sachs lesion with bone allograft. Although the procedure of segmental reconstruction has been used in several studies, its technique has not yet been well described in detail. In this report we propose a step-by-step description of the technique how to perform a segmental reconstruction of a reverse Hill-Sachs defect.
Wirth, Barbara; Kolling, Christoph; Schwyzer, Hans-Kaspar; Flury, Matthias; Audigé, Laurent
2016-07-01
Bilateral reverse shoulder arthroplasty (RSA) is controversial because of potential rotational deficits impairing daily living activities. We assessed achievement of insufficient internal rotation (IR) and associated factors in bilateral RSA patients. Fifty-seven staged bilateral RSA patients with a minimum of 1 year of follow-up after the second intervention were identified from our local monocentric register. Shoulder range of motion (including IR using the Apley scratch test), strength, and Constant and Shoulder Pain and Disability Index scores were assessed preoperatively and 6, 12, and 24 months postoperatively. Before surgery, both shoulders were similar regarding imaging parameters, but first operated shoulders tended to have poorer function. One year after the first RSA, 21% of patients had insufficient IR (not reaching the lumbosacral junction) compared with 33% after the second intervention (P = .180). At 2 years, 5% of patients had insufficient IR on both sides. Patients with insufficient IR on the second side at baseline (relative risk [RR], 1.8 [1.0-3.2]) and patients with insufficient IR 1 year after the first RSA (RR, 3.0 [1.6-5.6]) were more likely to have insufficient IR 1 year after the second RSA. Constant and Shoulder Pain and Disability Index scores and abduction of the second side were significantly worse 1 year after the second RSA (P ≤ .047); at 2 years, there were no differences in functional outcome between shoulders. A minority of bilateral RSA patients did not achieve sufficient IR on at least 1 side. Staged surgery is justified, particularly when the outcome of the initial operation is satisfactory. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
A Critical Review on Prosthetic Features Available for Reversed Total Shoulder Arthroplasty
De Wilde, Lieven
2016-01-01
Reversed total shoulder arthroplasty is a popular treatment in rotator cuff arthropathy and in displaced proximal humeral fractures in elderly. In 2016, 29 models of commercially available designs express this popularity. This study describes all the different design parameters available on the market. Prosthetic differences are found for the baseplate, glenosphere, polyethylene, and humeral component and these differences need to be weighed out carefully for each patient knowing that a gain in one mechanical parameter can balance the loss of another. Patient specific implants may help in the future. PMID:28105417
Sanchez-Sotelo, Joaquin; Wagner, Eric R; Sim, Franklin H; Houdek, Matthew T
2017-12-20
Reverse total shoulder arthroplasty (RTSA) performed in the setting of massive proximal humeral bone loss often requires special reconstructive techniques. Restoration of the proximal part of the humerus with an allograft provides a number of theoretical benefits, including implant support, restoration of humeral length, deltoid tensioning, and an opportunity to repair the posterior aspect of the cuff to improve strength in external rotation and repair of the subscapularis to improve stability. However, reverse allograft-prosthesis composites (APCs) are costly, are technically demanding to use, and can be compromised by progressive allograft resorption. Between 2005 and 2012, the lead author used an APC reconstruction in 8 primary and 18 revision RTSAs (26 patients; mean age, 62 years; mean body mass index, 27.9 kg/m). The indications for the primary RTSAs included severe proximal humeral bone loss after trauma (n = 5) and tumor resection (n = 3). The indications in the revision setting were failed hemiarthroplasty (n = 11), anatomic total shoulder arthroplasty (n = 4), and reverse arthroplasty (n = 3). The most common reason for revision was instability (n = 10). A compression plate was used for graft-to-host fixation in all shoulders. Shoulders were assessed for pain, motion, American Shoulder and Elbow Surgeons (ASES) score, Simple Shoulder Test (SST) score, Neer score, revision or reoperation, radiographic evidence of graft union or resorption, and implant fixation. The mean duration of follow-up was 4 years (range, 2 to 10 years). RTSA using an APC construct resulted in substantial improvements in pain scores (p < 0.0001), elevation (p < 0.0001), and external rotation (p = 0.004). With the numbers available, there were no significant differences in clinical outcomes between primary and revision cases. No patients required revision surgery for nonunion at the host-allograft junction. The mean time to union was 7 months, with 1 patient requiring bone-grafting for delayed union. Other complications included dislocation, deep infection, graft fracture, and periprosthetic fracture distal to the previous APC construct in 1 patient each. The 2 and 5-year revision-free survival rate was 96%. Reconstruction of proximal humeral bone loss with an APC at the time of primary or revision RTSA is safe and effective, with acceptable functional outcomes and complication rates. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
How do deltoid muscle moment arms change after reverse total shoulder arthroplasty?
Walker, David R; Struk, Aimee M; Matsuki, Keisuke; Wright, Thomas W; Banks, Scott A
2016-04-01
Although many advantages of reverse total shoulder arthroplasty (RTSA) have been demonstrated, a variety of complications indicate there is much to learn about how RTSA modifies normal shoulder function. This study used a subject-specific computational model driven by in vivo kinematic data to assess how RTSA affects deltoid muscle moment arms after surgery. A subject-specific 12 degree-of-freedom musculoskeletal model was used to analyze the shoulders of 26 individuals (14 RTSA and 12 normal). The model was modified from the work of Holzbaur to directly input 6 degree-of-freedom humeral and scapular kinematics obtained using fluoroscopy. The moment arms of the anterior, lateral, and posterior aspects of the deltoid were significantly different when RTSA and normal cohorts were compared at different abduction angles. Anterior and lateral deltoid moment arms were significantly larger in the RTSA group at the initial elevation of the arm. The posterior deltoid was significantly larger at maximum elevation. There was large intersubject variability within the RTSA group. Placement of implant components during RTSA can directly affect the geometric relationship between the humerus and scapula and the muscle moment arms in the RTSA shoulder. RTSA shoulders maintain the same anterior and posterior deltoid muscle moment-arm patterns as healthy shoulders but show much greater intersubject variation and larger moment-arm magnitudes. These observations provide a basis for determining optimal implant configuration and surgical placement to maximize RTSA function in a patient-specific manner. Published by Elsevier Inc.
Brand, Henk S; Kamell, Hassib; Kharbanda, Aron K; Dozic, Alma
2013-09-01
The aim of this study was to explore the materials and procedures used by students in dental schools across Europe for teaching fixed prosthodontics. An online questionnaire, containing twenty-eight dichotomous, multiple-choice, and Likert scale rating questions, was sent to students in forty dental schools. After excluding dental schools in which less than 10 percent of the students responded, 775 questionnaires from ten schools remained for statistical analysis. Among these respondents, acrylic resin teeth were said to be the most commonly used material during preclinical practice (46-96 percent), and use of extracted teeth varied from 8 to 65 percent. At nine of the ten institutions, metal-ceramic was reported to be most commonly used for fixed dental prostheses. There was large variation in the type of finish line for a metal-ceramic fixed dental prosthesis: students at five institutions reported using a shoulder finish line, three a chamfer finish line, and two a shoulder-bevel finish line. A similar variation was observed with regard to the final cementation of metal-ceramic fixed dental prostheses: students at four institutions reporting most frequently using glass ionomer cement, with three using zinc phosphate cement and three using carboxylate cement. The responding European dental students varied considerably in their opinions about whether they were preclinically properly trained for the first preparation on a patient and in their overall rating of their education in fixed prosthodontics. Responding students in the United Kingdom, Sweden, and Nijmegen, The Netherlands, rated their fixed prosthodontics training overall the highest. Overall, this study found a wide variation amongst dental schools with regard to their education in fixed prosthodontics and their rating of this teaching.
Shoulder Arthroplasty Imaging: What’s New
Gregory, T.M
2017-01-01
Background: Shoulder arthroplasty, in its different forms (hemiarthroplasty, total shoulder arthroplasty and reverse total shoulder arthroplasty) has transformed the clinical outcomes of shoulder disorders. Improvement of general clinical outcome is the result of stronger adequacy of the treatment to the diagnosis, enhanced surgical techniques, specific implanted materials, and more accurate follow up. Imaging is an important tool in each step of these processes. Method: This article is a review article declining recent imaging processes for shoulder arthroplasty. Results: Shoulder imaging is important for shoulder arthroplasty pre-operative planning but also for post-operative monitoring of the prosthesis and this article has a focus on the validity of plain radiographs for detecting radiolucent line and on new Computed Tomography scan method established to eliminate the prosthesis metallic artefacts that obscure the component fixation visualisation. Conclusion: Number of shoulder arthroplasties implanted have grown up rapidly for the past decade, leading to an increase in the number of complications. In parallel, new imaging system have been established to monitor these complications, especially component loosening PMID:29152007
Crosby, Lynn A; Wright, Thomas W; Yu, Stephen; Zuckerman, Joseph D
2017-05-03
Revision shoulder arthroplasty is a technically challenging procedure. It is associated with increased blood loss and operative time, and it frequently necessitates revision implants, augments, and bone-grafting. Shoulder arthroplasty systems with a convertible-platform humeral stem have been developed to reduce the complexity of revision procedures by eliminating the need for humeral component explantation when converting from anatomic shoulder arthroplasty (hemiarthroplasty or total shoulder arthroplasty) to reverse total shoulder arthroplasty (rTSA). A multicenter, retrospective analysis involving 102 consecutive shoulders (102 patients) that underwent revision of an anatomic shoulder arthroplasty to an rTSA was conducted. During the revision, 73 of the shoulders needed exchange of the humeral stem (the exchange group) and 29 had retention of a convertible-platform humeral component (the retention group). Patient demographics, operative time, blood management, range of motion, complications, and patient-reported outcomes were compared between the 2 groups. Patients with retention had significantly shorter operative time (mean and standard deviation, 130 ± 48 versus 195 ± 58 minutes; p < 0.001) and lower estimated blood loss (292 ± 118 versus 492 ± 334 mL; p = 0.034). The rate of intraoperative complications was lower in the retention group (0% versus 15%; p = 0.027). Patients with retention had slightly better postoperative range of motion (active external rotation, 26° ± 23° versus 11° ± 23° [p = 0.006]; active forward elevation, 112° ± 37° versus 96° ± 33° [p = 0.055]). Shoulder arthroplasty systems that utilize a convertible-platform humeral stem offer an advantage for rTSA conversion in that a well-fixed, well-positioned humeral stem can be retained. There were significantly fewer complications as well as significantly decreased blood loss and operative time when a convertible-platform stem was utilized (p < 0.050). Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alcaraz, Olga; Trullàs, Joaquim, E-mail: quim.trullas@upc.edu; Tahara, Shuta
2016-09-07
The results of the structural properties of molten copper chloride are reported from high-energy X-ray diffraction measurements, reverse Monte Carlo modeling method, and molecular dynamics simulations using a polarizable ion model. The simulated X-ray structure factor reproduces all trends observed experimentally, in particular the shoulder at around 1 Å{sup −1} related to intermediate range ordering, as well as the partial copper-copper correlations from the reverse Monte Carlo modeling, which cannot be reproduced by using a simple rigid ion model. It is shown that the shoulder comes from intermediate range copper-copper correlations caused by the polarized chlorides.
Salesky, Madeleine A; Grace, Trevor R; Feeley, Brian T; Ma, C Benjamin; Zhang, Alan L
2018-05-01
The influence of primary humeral stem fixation method (cemented or press fit) on intraoperative or postoperative outcomes in the setting of revision shoulder arthroplasty is unknown. A retrospective analysis of a prospectively collected cohort of revision shoulder arthroplasty patients from a single tertiary center was performed. Demographic variables, intraoperative data, and 90-day complication rates were compared between cemented and press-fit primary stem fixation cohorts. Follow-up radiographs were graded and compared using a modified Gruen system for humeral lucencies. Eighty-six primary shoulder replacements (34 hemiarthroplasties, 39 anatomic total shoulder arthroplasties, 13 reverse total shoulder arthroplasties) underwent revision arthroplasty with humeral stem removal between 2004 and 2017. Forty-five patients had cemented primary humeral fixation and 41 had press-fit fixation. The cemented cohort was older than the cementless cohort (66.6 vs. 61.4 years; P = .03) but otherwise demonstrated no difference in gender, body mass index, type of primary prosthesis (hemi, total, or reverse), or time between primary and revision operations. The cemented and cementless cohorts showed similar rates of humeral osteotomy (28.9% vs. 29.3%; P = .97), operative time (133.5 vs. 121.3 minutes; P = .16), and 90-day complication rates (13.3% vs. 9.8%; P = .61). Cemented vs. press-fit primary stems also had similar rates of humeral lucencies seen on follow-up radiographs after revision (77.1% vs. 60.6%; P = .14). Humeral stem fixation with or without cement during primary shoulder arthroplasty demonstrated similar operative time, need for intraoperative humeral osteotomy, and postoperative complication rates in the setting of revision arthroplasty. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Outcomes of reverse shoulder arthroplasty using a mini 25-mm glenoid baseplate.
Athwal, George S; Faber, Kenneth J
2016-01-01
As worldwide use of reverse shoulder arthroplasty (RSA) increases, a range of implant sizes may be required to match regional and ethnic variation in patients' height and bone size. The purpose of this study was to report the outcomes of RSA using a mini 25-mm-diameter glenoid baseplate in smaller patients with rotator cuff arthropathy. Between 2009 and 2012, 28 patients underwent RSA for cuff-tear arthropathy using a 25-mm circular glenoid baseplate (Aequlais Reversed, Tornier, Bloomington, MN, USA). Twenty-four patients were able to return for comprehensive follow-up. The mean height of the entire cohort was 158 ± 10 cm (5 ft. 2 in.). The indication to use a smaller baseplate was a combination of preoperative templating using computed tomography (CT) and intraoperative measurements of glenoid width. At a mean of 36 ± 8 months' follow-up, there were no revisions or glenoid-sided failures. The mean American Shoulder and Elbow Surgeons (ASES) score was 70 ± 10, the Simple Shoulder Test (SST) was 10 ± 2, the Constant was 60 ± 10 and the Disabilities of the Arm, Shoulder and Hand (DASH) was 18 ± 15. Mean active forward elevation was 140 ± 15°, active external rotation was 21 ± 15° and active internal rotation was to the sacroiliac joint. Mean shoulder strength in flexion was 5.2 ± 1.7 kg, in external rotation was 2.9 ± 1.4 kg and in internal rotation was 4.3 ± 1.2 kg. Radiographs demonstrated no evidence of glenoid loosening. There was, however, a 62 % rate of scapular notching. Short-term outcomes of mini 25-mm baseplate RSA in proportionally smaller patients are good and demonstrate implant safety and effectiveness. Scapular notching rates are worrisome, and additional follow-up is necessary to determine if notching is progressive and becomes symptomatic.
Fritz, Jan; U-Thainual, Paweena; Ungi, Tamas; Flammang, Aaron J.; Fichtinger, Gabor; Iordachita, Iulian I.
2012-01-01
Purpose: To prospectively assess overlay technology in providing accurate and efficient targeting for magnetic resonance (MR) imaging–guided shoulder and hip joint arthrography. Materials and Methods: A prototype augmented reality image overlay system was used in conjunction with a clinical 1.5-T MR imager. A total of 24 shoulder joint and 24 hip joint injections were planned in 12 human cadavers. Two operators (A and B) participated, each performing procedures on different cadavers using image overlay guidance. MR imaging was used to confirm needle positions, monitor injections, and perform MR arthrography. Accuracy was assessed according to the rate of needle adjustment, target error, and whether the injection was intraarticular. Efficiency was assessed according to arthrography procedural time. Operator differences were assessed with comparison of accuracy and procedure times between the operators. Mann-Whitney U test and Fisher exact test were used to assess group differences. Results: Forty-five arthrography procedures (23 shoulders, 22 hips) were performed. Three joints had prostheses and were excluded. Operator A performed 12 shoulder and 12 hip injections. Operator B performed 11 shoulder and 10 hip injections. Needle adjustment rate was 13% (six of 45; one for operator A and five for operator B). Target error was 3.1 mm ± 1.2 (standard deviation) (operator A, 2.9 mm ± 1.4; operator B, 3.5 mm ± 0.9). Intraarticular injection rate was 100% (45 of 45). The average arthrography time was 14 minutes (range, 6–27 minutes; 12 minutes [range, 6–25 minutes] for operator A and 16 minutes [range, 6–27 min] for operator B). Operator differences were not significant with regard to needle adjustment rate (P = .08), target error (P = .07), intraarticular injection rate (P > .99), and arthrography time (P = .22). Conclusion: Image overlay technology provides accurate and efficient MR guidance for successful shoulder and hip arthrography in human cadavers. © RSNA, 2012 Supplemental material: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12112640/-/DC1 PMID:22843764
Failure after reverse total shoulder arthroplasty: what is the success of component revision?
Black, Eric M; Roberts, Susanne M; Siegel, Elana; Yannopoulos, Paul; Higgins, Laurence D; Warner, Jon J P
2015-12-01
Complication rates remain high after reverse total shoulder arthroplasty (RTSA). Salvage options after implant failure have not been well defined. This study examines the role of reimplantation and revision RTSA after failed RTSA, reporting outcomes and complications of this salvage technique. Sixteen patients underwent component revision and reimplantation after a prior failed RTSA from 2004 to 2011. Indications included baseplate failure (7 patients, 43.8%), instability (6 patients, 37.5%), infection (2 patients, 12.5%), and humeral loosening (1 patient, 6.3%). The average age of the patient during revision surgery was 68.6 years. Outcomes information at follow-up was recorded, including visual analog scale score for pain, subjective shoulder value, American Shoulder and Elbow Surgeons score, and Simple Shoulder Test score, and these were compared with pre-revision values. Repeated surgeries and complications were noted. Average time to follow-up from revision was 58.9 months (minimum, 2 years; range, 24-103 months). The average postoperative visual analog scale score for pain was 1.7/10 (7.5/10 preoperatively; P < .0001), and the subjective shoulder value was 62% (17% preoperatively; P < .0001). The average postoperative American Shoulder and Elbow Surgeons score was 66.7, and the Simple Shoulder Test score was 52.6. Fourteen patients (88%) noted that they felt "better" postoperatively than before their original RTSA and would go through the procedure again if given the option. Nine patients suffered major complications (56%), and 6 of these ultimately underwent further procedures (38% of cohort). Salvage options after failure of RTSA remain limited. Component revision and reimplantation can effectively relieve pain and improve function compared with baseline values, and patient satisfaction levels are moderately high. However, complication rates and reoperation rates are significant. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Periprosthetic shoulder infection in the United States: incidence and economic burden.
Padegimas, Eric M; Maltenfort, Mitchell; Ramsey, Matthew L; Williams, Gerald R; Parvizi, Javad; Namdari, Surena
2015-05-01
Periprosthetic joint infection (PJI) is a major cause of morbidity after shoulder arthroplasty. PJI epidemiology has not been well studied. We aimed to analyze the historical incidence, predisposing factors, and economic burden of PJI after shoulder arthroplasty in the United States. Primary shoulder arthroplasty patients were identified by the International Classification of Diseases, Ninth Revision, Clinical Modification codes 81.80 (total shoulder arthroplasty), 81.81 (hemiarthroplasty), and 81.88 (reverse arthroplasty) in the Nationwide Inpatient Sample from 2002 to 2011. PJI was identified by codes 80.01 (arthrotomy for device removal) and 996.66 (prosthetic infection). Multivariate logistic regression analysis was used to identify predisposing factors for PJI. PJI rate was 0.98% from 2002 to 2011 and did not vary significantly. Comorbidities associated with PJI were weight loss/nutritional deficiency (odds ratio [OR], 2.62; 95% confidence interval [CI], 1.53-4.51; P = .00047), drug abuse (OR, 2.38; 95% CI, 1.41-4.02; P = .0011), and anemia from blood loss (OR, 2.43; 95% CI, 1.50-3.93; P = .00031) or iron deficiency (OR, 2.05; 95% CI, 1.69-2.49; P < .0001). Demographic factors associated with PJI were younger age (OR, 1.020; 95% CI, 1.017-1.024; P < .0001) and male gender (OR, 1.961; 95% CI, 1.816-2.117; P < .0001). In 2011, median hospitalization costs for PJI were $17,163.57 compared with $16,132.68, $13,955.83, and $20,007.87 for total shoulder arthroplasty, hemiarthroplasty, and reverse arthroplasty, respectively. Increasing incidence of shoulder arthroplasty and a constant infection rate will result in greater overall PJI burden. Whereas hospitalization costs for PJI are comparable to those of primary arthroplasty, they are incurred after the original cost of shoulder arthroplasty. Certain identifiable patient variables correlate with higher PJI rates. Risk factor modification may decrease PJI incidence and help contain costs. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Villodre-Jiménez, J; Estrems-Díaz, V; Diranzo-García, J; Bru-Pomer, A
The treatment of 3and 4 part proximal humeral fractures in elderly patients is still controversial. The frequent co-existence of poor quality bone and rotator cuff abnormalities in patients with multiple clinical conditions and with difficulties for physical rehabilitation leads to disappointing clinical results, even when the radiological images are acceptable. To evaluate the clinical, radiological, and functional results in patients over 65 years old with complex proximal humerus fractures treated with reverse shoulder arthroplasty. A prospective review was carried out on 30 patients (26 women and 4 men) with proximal humeral fractures treated with reverse shoulder arthroplasty in our department. The mean age was 74.9 years (SD=6.3), and the mean follow-up was 34.5 months (SD=19.3). Clinical and functional results were acceptable, with a mean forward flexion of 124° and a mean external rotation of 13°. The mean abbreviated Constant abbreviated score was 49.1 (SD=14.1), 27 (SD=6.3) in the UCLA scale, and 32.2 (SD=19.2) in the QuickDASH questionnaire. The large majority (80%) of the patients are pain free, and they do not need medication to do daily activities. The complication rate was 13.3%. We consider that reverse shoulder arthroplasty is a valid option to treat 3and 4 part proximal humeral fractures in elderly patients. The surgical goals should include the anatomical reconstruction of the tuberosities, avoiding enlargement of the operated arm greater than 2cm. Copyright © 2016 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Scapular notching in reverse shoulder arthroplasty: validation of a computer impingement model.
Roche, Christopher P; Marczuk, Yann; Wright, Thomas W; Flurin, Pierre-Henri; Grey, Sean G; Jones, Richard B; Routman, Howard D; Gilot, Gregory J; Zuckerman, Joseph D
2013-01-01
The purpose of this study is to validate a reverse shoulder computer impingement model and quantify the impact of implant position on scapular impingement by comparing it to that of a radiographic analysis of 256 patients who received the same prosthesis and were followed postoperatively for an average of 22.2 months. A geometric computer analysis quantified anterior and posterior scapular impingement as the humerus was internally and externally rotated at varying levels of abduction and adduction relative to a fixed scapula at defined glenoid implant positions. These impingement results were compared to radiographic study of 256 patients who were analyzed for notching, glenoid baseplate position, and glenosphere overhang. The computer model predicted no impingement at 0° humeral abduction in the scapular plane for the 38 mm, 42 mm, and 46 mm devices when the glenoid baseplate cage peg is positioned 18.6 mm, 20.4 mm, and 22.7 mm from the inferior glenoid rim (of the reamed glenoid) or when glenosphere overhang of 4.6 mm, 4.7 mm, and 4.5 mm was obtained with each size glenosphere, respectively. When compared to the radiographic analysis, the computer model correctly predicted impingement based upon glenoid base- plate position in 18 of 26 patients with scapular notching and based upon glenosphere overhang in 15 of 26 patients with scapular notching. Reverse shoulder implant positioning plays an important role in scapular notching. The results of this study demonstrate that the computer impingement model can effectively predict impingement based upon implant positioning in a majority of patients who developed scapular notching clinically. This computer analysis provides guidance to surgeons on implant positions that reduce scapular notching, a well-documented complication of reverse shoulder arthroplasty.
Levy, Jonathan C; Everding, Nathan G; Gil, Carlos C; Stephens, Scott; Giveans, M Russell
2014-12-01
Whereas patient expectations after anatomic total shoulder arthroplasty (TSA) and reverse shoulder arthroplasty (RSA) relate to sustained improvements in pain, function, and motion, the time necessary to reach these goals is unclear. Our purpose was to investigate the speed of recovery and to compare the effectiveness of primary TSA and RSA. We analyzed (preoperative, 3 month, 6 month, 1-year, and 2-year scores) pain scores, functional scores, and motion for 122 patients treated with primary RSA and 166 patients treated with primary TSA with a minimum of 1 year of follow-up. Comparisons were made to determine the effectiveness of treatment, time required to reach a plateau in improvement, and percentage of overall improvement at 3 and 6 months. Significant improvements were observed for both TSA and RSA at all intervals (P < .001), except with internal rotation for RSA. Pain relief was rapid after both TSA and RSA. TSA patients reached a consistent plateau for pain and function by 6 months and for shoulder elevation by 1 year. RSA patients demonstrated variability with multiple false plateau points. By 6 months, TSA patients had achieved 90% to 100% of functional improvement, whereas RSA patients reached 72% to 91%. The effectiveness of TSA was greater than that of RSA for all measures with the exception of elevation and abduction. Whereas patients treated with primary TSA and RSA can expect rapid improvements in pain, those treated with TSA can anticipate a more consistent and effective recovery of pain, function, and shoulder rotation. Patients receiving RSA can expect a variable length of recovery with greater improvements in forward elevation and abduction. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Merolla, Giovanni; Wagner, Eric; Sperling, John W; Paladini, Paolo; Fabbri, Elisabetta; Porcellini, Giuseppe
2018-01-01
There remains a paucity of studies examining the conversion of failed hemiarthroplasty (HA) to reverse total shoulder arthroplasty (RTSA). Therefore, the purpose of this study was to examine a large series of revision HA to RTSA. A population of 157 patients who underwent conversion of a failed HA to a revision RTSA from 2006 through 2014 were included. The mean follow-up was 49 months (range, 24-121 months). The indications for revision surgery included instability with rotator cuff insufficiency (n = 127) and glenoid wear (n = 30); instability and glenoid wear were associated in 38 cases. Eight patients with infection underwent 2-stage reimplantation. Patients experienced significant improvements in their preoperative to postoperative pain and shoulder range of motion (P < .0001), with median American Shoulder and Elbow Surgeons and Simple Shoulder Test scores of 60 and 6 points, respectively. There were 11 (7%) repeated revision surgeries, secondary to glenoid component loosening (n = 3), instability (n = 3), humeral component disassembly (n = 2), humeral stem loosening (n = 1), and infection (n = 2). Implant survivorship was 95.5% at 2 years and 93.3% at 5 years. There were 4 reoperations including axillary nerve neurolysis (n = 2), heterotopic ossification removal (n = 1), and hardware removal for rupture of the metal cerclage for an acromial fracture (n = 1). At final follow-up, there were 5 "at-risk" glenoid components. Patients experience satisfactory pain relief and recovery of reasonable shoulder function after revision RTSA from a failed HA. There was a relatively low revision rate, with glenoid loosening and instability being the most common causes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Pastor, Marc-Frederic; Kraemer, Manuel; Wellmann, Mathias; Hurschler, Christof; Smith, Tomas
2016-11-01
The aim of this study was to investigate the stabilizing influence of the rotator cuff as well as the importance of glenosphere and onlay configuration on the anterior stability of the reverse total shoulder replacement (RTSR). A reverse total shoulder replacement was implanted into eight human cadaveric shoulders, and biomechanical testing was performed under three conditions: after implantation of the RTSR, after additional dissection of the subscapularis tendon, and after additional dissection of the infraspinatus and teres minor tendon. Testing was performed in 30° of abduction and three rotational positions: 30° internal rotation, neutral rotation, and 30° external rotation. Furthermore, the 38-mm and 42-mm glenospheres were tested in combination with a standard and a high-mobility humeral onlay. A gradually increased force was applied to the glenohumeral joint in anterior direction until the RTSR dislocated. The 42-mm glenosphere showed superior stability compared with the 38-mm glenosphere. The standard humeral onlay required significantly higher anterior dislocation forces than the more shallow high-mobility onlay. External rotation was the most stable position. Furthermore, isolated detachment of the subscapularis and combined dissection of the infraspinatus, teres minor, and subscapularis tendon increased anterior instability. This study showed superior stability with the 42-mm glenosphere and the more conforming standard onlay. External rotation was the most stable position. Detachment of the subscapularis as well as dissection of the complete rotator cuff decreased anterior stability.
Impact of Posterior Wear on Muscle Length with Reverse Shoulder Arthroplasty.
Roche, Christopher P; Diep, Phong; Hamilton, Matthew A; Wright, Thomas W; Flurin, Pierre-Henri; Zuckerman, Joseph D; Routman, Howard D
2015-12-01
The use of reverse total shoulder arthroplasty (rTSA) in patients with posterior glenoid wear can be challenging. Implanting a baseplate in the correct version may require significant eccentric reaming, which further medializes the joint line and results in greater rotator cuff muscle shortening. To restore the joint line, bone graft may be required, though it is associated with additional risks. As an alternative solution, augmented glenoid baseplates offer the potential to restore the joint line and improve rotator cuff muscle tensioning without the need for eccentric reaming or supplemental bone graft. To that end, this computer analysis quantifies the rotator cuff muscle length for standard and augmented rTSA when used in a normal and posteriorly worn glenoid. These results demonstrate that shortening of the rotator cuff occurred for both the standard and posterior augmented reverse shoulder designs with additional muscle shortening occurring in scapula with posteriorly worn glenoids. More anatomic rotator cuff muscle tensioning was observed with augmented glenoid baseplates. The use of posterior augmented glenoid baseplates has the potential to improve stability and better restore active internal and external rotation, a current limitation of rTSA. However, clinical follow-up is necessary to confirm these favorable biomechanical results.
Gulotta, L V; Choi, D; Marinello, P; Wright, T; Cordasco, F A; Craig, E V; Warren, R F
2012-12-01
Reverse total shoulder replacement (RTSR) depends on adequate deltoid function for a successful outcome. However, the anterior deltoid and/or axillary nerve may be damaged due to prior procedures or injury. The purpose of this study was to determine the compensatory muscle forces required for scapular plane elevation following RTSR when the anterior deltoid is deficient. The soft tissues were removed from six cadaver shoulders, except for tendon attachments. After implantation of the RTSR, the shoulders were mounted on a custom-made shoulder simulator to determine the mean force in each muscle required to achieve 30° and 60° of scapular plane elevation. Two conditions were tested: 1) Control with an absent supraspinatus and infraspinatus; and 2) Control with anterior deltoid deficiency. Anterior deltoid deficiency resulted in a mean increase of 195% in subscapularis force at 30° when compared with the control (p = 0.02). At 60°, the subscapularis force increased a mean of 82% (p < 0.001) and the middle deltoid force increased a mean of 26% (p = 0.04). Scapular plane elevation may still be possible following an RTSR in the setting of anterior deltoid deficiency. When the anterior deltoid is deficient, there is a compensatory increase in the force required by the subscapularis and middle deltoid. Attempts to preserve the subscapularis, if present, might maximise post-operative function.
Allen, Summer
2016-01-01
Forty years ago, Les Baugh lost both of his arms in an electrical accident. With bilateral shoulder-level amputations, his options for prosthetic arms were limited. That changed two years ago, when Baugh underwent a surgical procedure at Johns Hopkins Hospital in Baltimore that allowed him to control state-of-the-art robotic arms using nerves that had been rerouted to his chest. Within ten days of training, he was able to control both arms simultaneously and move a cup from a lower shelf to a higher shelf-a task that previously had been impossible-just by thinking about how he wanted to move his arm.
Cáceres-Sánchez, L; Mesa-Mateo, A; Barrionuevo-Sánchez, F J; García-Benítez, B; Expósito-Triano, S
2015-01-01
To evaluate the clinical results and analyse the complications of total reverse shoulder replacement performed in our centre over an 8 year period. A retrospective study was conducted on 50 patients (52 shoulders), with a mean age of 70.15 years (range 51 to 84 years) between December 2004 and December 2012, who received a total reverse shoulder replacement, all performed by the same surgeon. The results have been evaluated according to clinical data, radiography study, a satisfaction scale, and the Constant scale, with a minimum follow-up of 16 months. Five of the cases (9.62%) had been intervened due to fractures of the proximal end of the humerus, 6 cases (11.53%) as surgical consequence of a prosthesis revision, 10 cases (19.23%) due to fracture sequelae, and 30 cases (59.62%) were patients with arthropathy due to a massive fracture of the rotator cuff. After a mean follow up of 35.78 months (range, 16-82), satisfactory clinical results were obtained in 80% of cases, with a mean preoperative Constant of 27.7 points, and reaching 67.1 points 12 months after the operation. On the visual analogue scale, 8.25 points were obtained before the surgery, which decreased to 2.25 points 12 months later. The complications rate was 15.38%, which were due to an intra-operative fracture (1.92%), deep infection (3.84%), instability (3.84%), and early mechanical loosening (3.84%). Scapular notching was observed in the radiographic study in 9 (17.3%) cases. After the results obtained, it could be said that total reverse shoulder replacement achieved encouraging results in the short term for the treatment of glenohumeral arthrosis and massive tears of the rotary cuff. On analysing our series, it can be seen that the complications rate is much higher when it is used to treat fracture sequelae in which there is a loss of proximal humerus bone stock. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.
Preventing brachial plexus injury during shoulder surgery: a real-time cadaveric study.
Kam, Andrew W; Lam, Patrick H; Haen, Pieter S W A; Tan, Martin; Shamsudin, Aminudin; Murrell, George A C
2018-05-01
Brachial plexopathy is not uncommon after shoulder surgery. Although thought to be due to stretch neuropathy, its etiology is poorly understood. This study aimed to identify arm positions and maneuvers that may risk causing brachial plexopathy during shoulder arthroplasty. Tensions in the cords of the brachial plexuses of 6 human cadaveric upper limbs were measured using load cells while each limb was placed in different arm positions and while they underwent shoulder hemiarthroplasty and revision reverse arthroplasty. Arthroplasty procedures in 4 specimens were performed with standard limb positioning (unsupported), and 2 specimens were supported from under the elbow (supported). Each cord then underwent biomechanical testing to identify tension corresponding to 10% strain (the stretch neuropathy threshold in animal models). Tensions exceeding 15 N, 11 N, and 9 N in the lateral, medial, and posterior cords, respectively, produced 10% strain. Shoulder abduction >70° and combined external rotation >60° with extension >50° increased medial cord tension above the 10% strain threshold. Medial cord tensions (mean ± standard error of the mean) in unsupported specimens increased over baseline during hemiarthroplasty (sounder insertion [4.7 ± 0.6 N, P = .04], prosthesis impaction [6.1 ± 0.8 N, P = .04], and arthroplasty reduction [5.0 ± 0.7 N, P = .04]) and revision reverse arthroplasty (retractor positioning [7.2 ± 0.8 N, P = .02]). Supported specimens experienced lower tensions than unsupported specimens. Shoulder abduction >70°, combined external rotation >60° with extension >50°, and downward forces on the humeral shaft may risk causing brachial plexopathy. Retractor placement, sounder insertion, humeral prosthesis impaction, and arthroplasty reduction increase medial cord tensions during shoulder arthroplasty. Supporting the arm from under the elbow protected the brachial plexus in this cadaveric model. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Indications for reverse total shoulder arthroplasty in rotator cuff disease.
Drake, Gregory N; O'Connor, Daniel P; Edwards, T Bradley
2010-06-01
Reverse total shoulder arthroplasty (RTSA) was introduced to treat rotator cuff tear arthropathy but is now used to treat a variety of problems. Although its use has expanded substantially since the FDA's approval in 2004, the appropriateness in patients with rotator cuff disease is unclear. We review the use of RTSA in patients with rotator cuff disease to (1) describe classification of rotator cuff tear reparability and the concept of a balanced shoulder; (2) explore the theory behind RTSA design relative to rotator cuff arthropathy; (3) discuss the indications and contraindications for RTSA; and (4) review published outcomes of RTSA for rotator cuff arthropathy. We performed a selective review of the literature on the use of RTSA in the treatment of rotator cuff disease. Modern RTSA designs restore deltoid tension and a functional fulcrum to the rotator cuff deficient shoulder, which allows recovery of active shoulder elevation and effectively restores function in short- and medium-term followup studies. In short-term followup the RTSA relieves symptoms and restores function for patients with cuff tear arthropathy and irreparable rotator cuff tears with pseudoparalysis (preserved deltoid contraction but loss of active elevation). Severely impaired deltoid function, an isolated supraspinatus tear, and the presence of full active shoulder elevation with a massive rotator cuff tear and arthritis are contraindications to RTSA. For properly selected patients who have symptomatic and disabling rotator cuff deficiency, RTSA can result in life-changing improvements in pain, motion, function, and patient satisfaction. Level V therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Herrmann, Sebastian; König, Christian; Heller, Markus; Perka, Carsten; Greiner, Stefan
2011-08-16
After reverse shoulder arthroplasty (RSA) external and internal rotation will often remain restricted. A postoperative alteration of the biomechanics in the remaining cuff is discussed as a contributing factor to these functional deficits. In this study, muscle moment arms as well as origin-to-insertion distance (OID) were calculated using three-dimensional models of the shoulder derived from CT scans of seven cadaveric specimens. Moment arms for humeral rotation are significantly smaller for the cranial segments of SSC and all segments of TMIN in abduction angles of 30 degrees and above (p ≤ 0.05). Abduction moment arms were significantly decreased for all segments (p ≤ 0.002). OID was significantly smaller for all muscles at the 15 degree position (p ≤ 0.005), apart from the cranial SSC segment. Reduced rotational moment arms in conjunction with the decrease of OID may be a possible explanation for the clinically observed impaired external and internal rotation.
Tauro, Joseph C
2018-04-01
Are we doing too many reverse total shoulder replacements and not fixing enough repairable rotator cuff tears? A convincing argument can be made for attempting to repair most, not all, very large rotator cuff tears in patients who do not have a significant arthritic change in the shoulder. My experience over more than 25 years of arthroscopic rotator cuff repair (ARCR) is that the only good way to know if it is repairable is to try. But some patients really do not pass my "eyeball test" as to whether they can rehabilitate and heal enough to make an ARCR reasonable. Magnetic resonance imaging scans are useful, mostly to help me with tear pattern recognition, how much time and skill I might need for the repair, and to help me council my patients as to their ultimate functional recovery. I have had surprises both ways: some ARCRs that I thought would be easy turned out to be very challenging and others that I thought would be "mission impossible" turned out to be "mission accomplished"! The rationale for jumping ahead primarily to reverse total shoulder replacements reminds me of certain tax cut plans I have heard talk of lately. Sounds great now (well, maybe the complication rate is a little high) but there might be a price to pay down the road. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Williams, Matthew D; Edwards, Thomas Bradley; Walch, Gilles
2018-03-01
Although the teres minor is often overlooked in a normal shoulder, it becomes a key component in maintaining shoulder function when other rotator cuff tendons fail. The teres minor maintains a balanced glenohumeral joint and changes from an insignificant to the most significant external rotator in the presence of major rotator cuff pathology. The presence or absence of the teres minor provides prognostic information on the outcomes of reverse total shoulder arthroplasty and tendon transfers. Clinical tests include the Patte test, the Neer dropping sign, the external rotation lag sign, and the Hertel drop sign. Advanced imaging of the teres minor can be used for classification using the Walch system. Understanding the function and pathology surrounding the teres minor is paramount in comprehensive management of the patient with shoulder pathology. Appropriate clinical examination and imaging of the teres minor are important for preoperative stratification and postoperative expectations.
Shoulder Arthroplasty, from Indications to Complications: What the Radiologist Needs to Know.
Lin, Dana J; Wong, Tony T; Kazam, Jonathan K
2016-01-01
The replaced shoulder is increasingly encountered by the radiologist, both on a dedicated and incidental basis, in this era of the growing population of aging patients wishing to preserve their mobility and function. Knowledge of the normal biomechanics of the glenohumeral joint-particularly the function of the rotator cuff and the unique relationship of the humeral head to the glenoid-is essential for understanding the need for shoulder replacement and its subsequent complications, because the intent of shoulder arthroplasty is to approximate the normal joint as closely as possible. The most common indications for shoulder arthroplasty are osteoarthritis, inflammatory arthritis, proximal humerus fractures, irreparable rotator cuff tears, rotator cuff arthropathy, and avascular necrosis of the humeral head. Knowledge of the key imaging features of these indications helps facilitate a correlative understanding between the initial diagnosis and the choice of which type of arthroplasty is used-total shoulder arthroplasty, reverse total shoulder arthroplasty, or partial joint replacement (humeral head resurfacing arthroplasty or hemiarthroplasty). The preoperative requirements and usual postoperative appearance of each arthroplasty type are summarized, as well as the complications of shoulder arthroplasty, including those unique to or closely associated with each type of arthroplasty and those that can be encountered with any type of shoulder arthroplasty. ©RSNA, 2016.
[Total Joint Replacement and Return to Sports].
Oehler, N; Schmidt, T; Niemeier, A
2016-12-01
Background: An increasing number of physically active patients not only need to know if they will basically be able to engage in sports after undergoing arthroplasty. They also would like to know whether or not they will be able to resume their preoperative activity levels. This article aims to provide an overview of recent data regarding the following questions on hip, knee and shoulder arthroplasty: (1) What is the impact of physical activity on an endoprosthesis? (2) What level of sports can be achieved after an arthroplasty procedure? (3) What types of sport are recommended for patients with an endoprosthesis? Methods: PubMed-based review of the literature. Narrative review focusing on current data from the years 2010 to 2016. Results: The commonly known recommendation to exercise low-impact sports such as hiking, swimming, cycling or golf at a moderate intensity remains valid for all types of prostheses in all joints. There is broad consensus that the benefits of these sports outweigh the negative effects. Having undergone total hip or knee arthroplasty, most patients with a high preoperative activity level return to sports after 3-6 months, albeit with a clear tendency to lower intensity and a shift from high-impact to low-impact sports. Some key questions have to be answered regarding the effects of low-impact sports that are exercised with high intensity, the effects resulting from high-impact sports, effects specific to different types of sport, and possibilities provided by different prosthesis types. In this context, a lot remains to be done to investigate the limits between positive and negative effects resulting from physical activity of varying intensity. New data suggests that generally a higher physical performance level may be achieved than has been traditionally recommended. Early results of unicondylar knee prostheses are far better than those achieved with bicondylar prostheses. In contrast to expert recommendations, shoulder endoprostheses show the highest postoperative activity levels after inverted arthroplasty, followed by anatomic arthroplasty, and the lowest activity level after the implantation of a hemiprosthesis. Conclusion: There is a significant discrepancy between previous expert recommendations and the actual activity levels that may be achieved after the implantation of a joint prosthesis. Future studies have to define the sports level, the type of sports and the type of prosthesis that provide a positive benefit-risk ratio using state-of-the-art low-abrasion bearing surfaces and prosthesis designs. © Georg Thieme Verlag KG Stuttgart · New York.
Oh, Joo Han; Shin, Sang-Jin; McGarry, Michelle H; Scott, Jonathan H; Heckmann, Nathanael; Lee, Thay Q
2014-08-01
The variability in functional outcomes and the occurrence of scapular notching and instability after reverse total shoulder arthroplasty remain problems. The objectives of this study were to measure the effect of reverse humeral component neck-shaft angle on impingement-free range of motion, abduction moment, and anterior dislocation force and to evaluate the effect of subscapularis loading on dislocation force. Six cadaveric shoulders were tested with 155°, 145°, and 135° reverse shoulder humeral neck-shaft angles. The adduction angle at which bone contact occurred and the internal and external rotational impingement-free range of motion angles were measured. Glenohumeral abduction moment was measured at 0° and 30° of abduction, and anterior dislocation forces were measured at 30° of internal rotation, 0°, and 30° of external rotation with and without subscapularis loading. Adduction deficit angles for 155°, 145°, and 135° neck-shaft angle were 2° ± 5° of abduction, 7° ± 4° of adduction, and 12° ± 2° of adduction (P < .05). Impingement-free angles of humeral rotation and abduction moments were not statistically different between the neck-shaft angles. The anterior dislocation force was significantly higher for the 135° neck-shaft angle at 30° of external rotation and significantly higher for the 155° neck-shaft angle at 30° of internal rotation (P < .01). The anterior dislocation forces were significantly higher when the subscapularis was loaded (P < .01). The 155° neck-shaft angle was more prone to scapular bone contact during adduction but was more stable at the internally rotated position, which was the least stable humeral rotation position. Subscapularis loading gave further anterior stability with all neck-shaft angles at all positions. Published by Mosby, Inc.
Throckmorton, Thomas W; Gulotta, Lawrence V; Bonnarens, Frank O; Wright, Stephen A; Hartzell, Jeffrey L; Rozzi, William B; Hurst, Jason M; Frostick, Simon P; Sperling, John W
2015-06-01
The purpose of this study was to compare the accuracy of patient-specific guides for total shoulder arthroplasty (TSA) with traditional instrumentation in arthritic cadaver shoulders. We hypothesized that the patient-specific guides would place components more accurately than standard instrumentation. Seventy cadaver shoulders with radiographically confirmed arthritis were randomized in equal groups to 5 surgeons of varying experience levels who were not involved in development of the patient-specific guidance system. Specimens were then randomized to patient-specific guides based off of computed tomography scanning, standard instrumentation, and anatomic TSA or reverse TSA. Variances in version or inclination of more than 10° and more than 4 mm in starting point were considered indications of significant component malposition. TSA glenoid components placed with patient-specific guides averaged 5° of deviation from the intended position in version and 3° in inclination; those with standard instrumentation averaged 8° of deviation in version and 7° in inclination. These differences were significant for version (P = .04) and inclination (P = .01). Multivariate analysis of variance to compare the overall accuracy for the entire cohort (TSA and reverse TSA) revealed patient-specific guides to be significantly more accurate (P = .01) for the combined vectors of version and inclination. Patient-specific guides also had fewer instances of significant component malposition than standard instrumentation did. Patient-specific targeting guides were more accurate than traditional instrumentation and had fewer instances of component malposition for glenoid component placement in this multi-surgeon cadaver study of arthritic shoulders. Long-term clinical studies are needed to determine if these improvements produce improved functional outcomes. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Henninger, Heath B; Barg, Alexej; Anderson, Andrew E; Bachus, Kent N; Burks, Robert T; Tashjian, Robert Z
2012-09-01
Lateral offset center of rotation (COR) reduces the incidence of scapular notching and potentially increases external rotation range of motion (ROM) after reverse total shoulder arthroplasty (rTSA). The purpose of this study was to determine the biomechanical effects of changing COR on abduction and external rotation ROM, deltoid abduction force, and joint stability. A biomechanical shoulder simulator tested cadaveric shoulders before and after rTSA. Spacers shifted the COR laterally from baseline rTSA by 5, 10, and 15 mm. Outcome measures of resting abduction and external rotation ROM, and abduction and dislocation (lateral and anterior) forces were recorded. Resting abduction increased 20° vs native shoulders and was unaffected by COR lateralization. External rotation decreased after rTSA and was unaffected by COR lateralization. The deltoid force required for abduction significantly decreased 25% from native to baseline rTSA. COR lateralization progressively eliminated this mechanical advantage. Lateral dislocation required significantly less force than anterior dislocation after rTSA, and both dislocation forces increased with lateralization of the COR. COR lateralization had no influence on ROM (adduction or external rotation) but significantly increased abduction and dislocation forces. This suggests the lower incidence of scapular notching may not be related to the amount of adduction deficit after lateral offset rTSA but may arise from limited impingement of the humeral component on the lateral scapula due to a change in joint geometry. Lateralization provides the benefit of increased joint stability, but at the cost of increasing deltoid abduction forces. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Hartzler, Robert U; Steen, Brandon M; Hussey, Michael M; Cusick, Michael C; Cottrell, Benjamin J; Clark, Rachel E; Frankle, Mark A
2015-11-01
Some patients unexpectedly have poor functional improvement after reverse shoulder arthroplasty (RSA) for massive rotator cuff tear without glenohumeral arthritis. Our aim was to identify risk factors for this outcome. We also assessed the value of RSA for cases with poor functional improvement vs. The study was a retrospective case-control analysis for primary RSA performed for massive rotator cuff tear without glenohumeral arthritis with minimum 2-year follow-up. Cases were defined as Simple Shoulder Test (SST) score improvement of ≤1, whereas controls improved SST score ≥2. Risk factors were chosen on the basis of previous association with poor outcomes after shoulder arthroplasty. Latissimus dorsi tendon transfer results were analyzed as a subgroup. Value was defined as improvement in American Shoulder and Elbow Surgeons (ASES) score per $10,000 hospital cost. In a multivariate binomial logistic regression analysis, neurologic dysfunction (P = .006), age <60 years (P = .02), and high preoperative SST score (P = .03) were independently associated with poor functional improvement. Latissimus dorsi tendon transfer patients significantly improved in active external rotation (-0.3° to 38.7°; P < .01). The value of RSA (ΔASES/$10,000 cost) for cases was 0.8 compared with 17.5 for controls (P < .0001). Young age, high preoperative function, and neurologic dysfunction were associated with poor functional improvement. Surgeons should consider these associations in counseling and selection of patients. Concurrent latissimus dorsi transfer was successful in restoring active external rotation in a subgroup of patients. The critical economic importance of improved patient selection is emphasized by the very low value of the procedure in the case group. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Song, Kwang-Soon; Koo, Tae-Won
2017-01-01
Background The purpose of this study was to investigate the results and complications during the learning curve of reverse total shoulder arthroplasty (RTSA) for rotator cuff deficiency. Methods We retrospectively reviewed the first 40 cases of RTSA performed by a single surgeon. The mean age of patients was 72.7 years (range, 63 to 81 years) and mean follow-up period was 26.7 months (range, 9 to 57 months). Clinical outcomes were evaluated using a visual analog scale (VAS) for pain, the University of California at Los Angeles (UCLA) shoulder score, American Shoulder and Elbow Surgeon (ASES) score, subjective shoulder value (SSV), and active range of motion (ROM). Intraoperative and postoperative complications were also evaluated. Results The average VAS pain score, UCLA score, ASES score, and SSV improved from 6.9%, 12.8%, 29.0%, and 29.0% before surgery to 1.6%, 27.0%, 73.3%, and 71.5% after surgery, respectively (p < 0.001). The mean forward flexion, abduction, and external rotation improved from 68.0°, 56.9°, and 28.0° before surgery to 131.0°, 112.3°, and 38.8° after surgery, respectively (p < 0.001, p < 0.001, and p = 0.021). However, the mean internal rotation did not improve after surgery (p = 0.889). Scapular notching was observed in 33 patients (51.5%). Eight shoulders (20%) had complications, including 2 major (1 deep infection and 1 glenoid fixation failure) and 6 minor complications (3 brachial plexus injuries, 2 acromial fractures, and 1 intraoperative periprosthetic fracture). Conclusions The first 40 cases of RTSA performed by a single surgeon during the learning curve period showed satisfactory short-term follow-up results with an acceptable complication rate. PMID:28567225
Shoulder arthroplasty for sequelae of poliomyelitis.
Werthel, Jean-David; Schoch, Bradley; Sperling, John W; Cofield, Robert; Elhassan, Bassem T
2016-05-01
Polio infection can often lead to orthopedic complications such as arthritis, osteoporosis, muscle weakness, skeletal deformation, and chronic instability of the joints. The purpose of this study was to assess the outcomes and associated complications of arthroplasty in shoulders with sequelae of poliomyelitis. Seven patients (average age, 70 years) were treated between 1976 and 2013 with shoulder arthroplasty for the sequelae of polio. One patient underwent reverse shoulder arthroplasty, 2 had a hemiarthroplasty, and 4 had total shoulder arthroplasty. Average follow-up was 87 months. Outcome measures included pain, range of motion, and postoperative modified Neer ratings. Overall pain scores improved from 5 to 1.6 points (on a 5-point scale) after shoulder arthroplasty. Six shoulders had no or mild pain at latest follow-up, and 6 shoulders rated the result as much better or better. Mean shoulder elevation improved from 72° to 129°, and external rotation improved from 11° to 56°. Average strength in elevation decreased from 3.9 to 3.4 postoperatively, and external rotation strength decreased from 3.9 to 3.3. This, however, did not reach significance. Evidence of muscle imbalance with radiographic instability was found in 4 shoulders that demonstrated superior subluxation, anterior subluxation, or both. This remained asymptomatic. No shoulder required revision or reoperation. Shoulder arthroplasty provides significant pain relief and improved motion in patients with sequelae of poliomyelitis. Muscle weakness may be responsible for postoperative instability, and careful selection of the patient with good upper extremity muscles must be made. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Laver, Lior; Garrigues, Grant E
2014-10-01
Superior tilt of the baseplate component in reverse total shoulder arthroplasty leads to tensile baseplate forces and may be a contributor to early loosening. The risk factors for this implant malposition include inadequate exposure through a superior approach and superior glenoid bone deficiency that obscures the native glenoid tilt. Here we review our preoperative evaluation and surgical management strategies to avoid superior tilt. Adequate exposure with a superior approach can be achieved but requires not just proper surgical technique but also careful patient selection. We propose that the superior approach be considered only for acute proximal humerus fractures or in patients when the following criteria are met: no prior open surgery on the shoulder; more than 30° of passive external rotation at 0° of abduction; no medial humeral osteophytes; and any superior migration must be reducible with a sulcus test during examination under anesthesia. Avoiding superior tilt when there is significant superior glenoid erosion can be accomplished with humeral head autograft, most easily performed through a deltopectoral approach. Preoperative templating is critical to determine proper graft thickness, inclination, reaming depth, and harvest technique. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Shi, Lewis L; Cahill, Kirk E; Ek, Eugene T; Tompson, Jeffrey D; Higgins, Laurence D; Warner, Jon J P
2015-10-01
In patients with rotator cuff dysfunction, reverse shoulder arthroplasty can restore active forward flexion, but it does not provide a solution for the lack of active external rotation because of infraspinatus and the teres minor dysfunction. A modified L'Episcopo procedure can be performed in the same setting wherein the latissimus dorsi and teres major tendons are transferred to the lateral aspect of proximal humerus in an attempt to restore active external rotation. (1) Do latissimus dorsi and teres major tendon transfers with reverse shoulder arthroplasty improve external rotation function in patients with posterosuperior rotator cuff dysfunction? (2) Do patients experience less pain and have improved outcome scores after surgery? (3) What are the complications associated with reverse shoulder arthroplasty with latissimus dorsi and teres major transfer? Between 2007 and 2010, we treated all patients undergoing shoulder arthroplasty who had a profound external rotation lag sign and advanced fatty degeneration of the posterosuperior rotator cuff (infraspinatus plus teres minor) with this approach. A total of 21 patients (mean age 66 years; range, 58-82 years) were treated this way and followed for a minimum of 2 years (range, 26-81 months); none was lost to followup, and all have been seen in the last 5 years. We compared pre- and postoperative ranges of motion, pain, and functional status; scores were drawn from chart review. We also categorized major and minor complications. Active forward flexion improved from 56° ± 36° to 120° ± 38° (mean difference: 64° [95% confidence interval {CI}, 45°-83°], p < 0.001). Active external rotation with the arm adducted improved from 6° ± 16° to 38° ± 14° (mean difference: 30° [95% CI, 21°-39°], p < 0.001); active external rotation with the arm abducted improved from 19° ± 25° to 74° ± 22° (mean difference: 44° [95% CI, 22°-65°], p < 0.001). Pain visual analog score improved from 8.4 ± 2.3 to 1.7 ± 2.1 (mean difference: -6.9 [95% CI, -8.7 to -5.2], p < 0.001), and Single Assessment Numeric Evaluation score improved from 28% ± 21% to 80% ± 24% (mean difference: 46% [95% CI, 28%-64%], p < 0.001). There were six major complications, five of which were treated operatively. Overall, three patients' latissimus and teres major transfer failed based on persistent lack of external rotation. In patients with posterior and superior cuff deficiency, reverse shoulder arthroplasty combined with latissimus dorsi and teres major transfer through a single deltopectoral incision can reliably increase active forward flexion and external rotation. Patients experience pain relief and functional improvement but have a high rate of complications; therefore, we recommend the procedure be limited to patients indicated for reverse who have profound external rotation loss and a high grade of infraspinatus/teres minor fatty atrophy. Level IV, therapeutic study.
Return to sports after shoulder arthroplasty
Johnson, Christine C; Johnson, Daniel J; Liu, Joseph N; Dines, Joshua S; Dines, David M; Gulotta, Lawrence V; Garcia, Grant H
2016-01-01
Many patients prioritize the ability to return to sports following shoulder replacement surgeries, including total shoulder arthroplasty (TSA), reverse total shoulder arthroplasty (RTSA), and hemiarthroplasty (HA). While activity levels after hip and knee replacements have been well-established in the literature, studies on this topic in the field of shoulder arthroplasty are relatively limited. A review of the literature regarding athletic activity after shoulder arthroplasty was performed using the PubMed database. All studies relevant to shoulder arthroplasty and return to sport were included. The majority of patients returned to their prior level of activity within six months following TSA, RTSA, and shoulder HA. Noncontact, low demand activities are permitted by most surgeons postoperatively and generally have higher return rates than contact sports or high-demand activities. In some series, patients reported an improvement in their ability to participate in sports following the arthroplasty procedure. The rates of return to sports following TSA (75%-100%) are slightly higher than those reported for HA (67%-76%) and RTSA (75%-85%). Patients undergoing TSA, RTSA, and shoulder HA should be counseled that there is a high probability that they will be able to return to their preoperative activity level within six months postoperatively. TSA has been associated with higher rates of return to sports than RTSA and HA, although this may reflect differences in patient population or surgical indication. PMID:27672564
van den Broek, M; Verborgt, O; Declercq, G
2017-11-01
Skeletal dysplasia in achondroplasia can affect all body joints - including the glenohumeral joint - and is prone to develop to degenerative osteoarthritis (OA). This may cause pain and mobility problems at young age. Surgical treatment is challenging due to the dysplastic anatomy of the shoulder joint - with a dysplastic deformed short humerus, a small, hypoplastic medialized glenoid and lateralized acromion - and the long life expectancy of these patients. The indications for reverse shoulder arthroplasty (RSA) evolved during years with rotator cuff tears and rotator cuff arthropathy in combination with or without glenohumeral OA as the main indicator, with good short to mid-term results. Long term results of RSA are rarely found in literature, especially in young patients. The use of a RSA in glenohumeral OA with an intact rotator cuff has rarely been reported. In this case report we present the ten-year clinical and radiographic results of a RSA for the treatment of degenerative OA with glenohumeral dysplasia in a young patient with achondroplasia. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Valenti, Philippe; Maqdes, Ali; Werthel, Jean-David
2017-10-01
The purpose of this study was to report clinical and radiological results of reverse shoulder arthroplasty (RSA) after failure of either a deltoid and/or a latissimus dorsi transfer. Between 2001 and 2011, ten patients (average age, 61 years) underwent primary RSA after a failed tendon transfer for irreparable postero-superior rotator cuff tear (five deltoid muscle transfers, four latissimus dorsi transfers and one both). Average follow-up was 48 months. Outcome measures included pain, range of motion and postoperative Constant-Murley score. Pain score improved significantly from a mean 8.3 to a mean 0.3. Mean shoulder elevation improved from 66 to 134°, and absolute Constant-Murley scores increased from 25.8 to 62.8 The mean improvement in external rotation was limited to 7.5°. Subjectively, six patients rated the result as much better and three rated it as better than before surgery. Failure of the tendon transfer with deterioration of the functional outcomes can be salvaged with a RSA with no impact on the expected outcome.
Factors affecting the stability of reverse shoulder arthroplasty: a biomechanical study.
Clouthier, Allison L; Hetzler, Markus A; Fedorak, Graham; Bryant, J Tim; Deluzio, Kevin J; Bicknell, Ryan T
2013-04-01
Despite the success of reverse shoulder arthroplasty (RSA) in treating patients with painful pseudoparalytic shoulders, instability is a common complication and currently the factors affecting stability are not well understood. The objective of this study was to investigate a number of factors as well as the interactions between factors to determine how they affect the stability of the prosthesis. These factors included: active arm posture (abduction and abduction plane angles), loading direction, glenosphere diameter and eccentricity, and humeral socket constraint. Force required to dislocate the joint, determined using a biomechanical shoulder simulator, was used as a measure of stability. A factorial design experiment was implemented to examine the factors and interactions. Actively increasing the abduction angle by 15° leads to a 30% increase in stability and use of an inferior-offset rather than a centered glenosphere improved stability by 17%. Use of a more constrained humeral socket also increased stability; but the effect was dependent on loading direction, with a 88% improvement for superior loading, 66% for posterior, 36% for anterior, and no change for inferior loading. Abduction plane angle and glenosphere diameter had no effect on stability. Increased glenohumeral abduction and the use of an inferior-offset glenosphere were found to increase the stability of RSA. Additionally, use of a more constrained humeral socket increased stability for anterior, posterior, and superior loading. These identified factor effects have the potential to decrease the risk of dislocation following RSA. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Aim, Florence; Werthel, Jean-David; Deranlot, Julien; Vigan, Marie; Nourissat, Geoffroy
2018-04-01
One of the most frequent demands from patients after shoulder replacement surgery is to return to sport. To determine the rate of return to sport after shoulder arthroplasty (total shoulder arthroplasty, reverse shoulder arthroplasty, hemiarthroplasty) in recreational athletes. Meta-analysis and systematic review. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were followed to perform this systematic review and meta-analysis of the results in the literature as well as the presentation of results. A search of the literature was performed in the electronic databases MEDLINE, Scopus, Embase, and the Cochrane Library. The quality of the included studies was evaluated according to the MINORS (Methodological Index for Nonrandomized Studies) score. Inclusion criteria were studies in English evaluating return to sport after shoulder replacement surgery and on patients practicing a sport regularly, whatever the level, with all ages and sports included. The main criterion was the rate of patients who returned to a sport activity. Nine studies were selected among the 35 identified, including a total of 613 patients (39% male and 61% female) with a mean age of 71.7 years (range, 22.6-92.6 years). All the included patients practiced sports before surgery. The most common reported sports were golf (n = 140), swimming (n = 128), and tennis (n = 54). The mean rate of return to sport was 80.7% (range, 57.1%-97.3%). All patients who returned to sport were practicing in the 3 months before surgery. No radiological data were reported in the literature. The subgroup analysis for resuming golf after shoulder arthroplasty revealed a rate of return to sport of 79.2% (95% CI, 62.9%-89.5%). In the swimming subgroup, the rate was 75.6% (95% CI, 61.3%-85.8%) and in the tennis subgroup was 63.5% (95% CI, 34.1%-85.5%). The subgroup analysis for reverse shoulder arthroplasty reported a lower rate of return to sport than for all types of shoulder arthroplasty combined: 76.5% (95% CI, 60%-87%) versus 80.7% (95% CI, 70.9%-87.8%), respectively. Most patients returned to sport after surgery, and all who returned to sport were practicing their sport in the 3 months before surgery. No radiological data were reported in the literature.
Shoulder Arthroplasty for Sequelae of Obstetrical Brachial Plexus Injury.
Werthel, Jean-David; Schoch, Bradley; Frankle, Mark; Cofield, Robert; Elhassan, Bassem T
2018-03-29
Shoulder arthroplasty following obstetrical brachial plexus injury (OBPI) is technically challenging because glenoid morphology, muscle balance, and humeral version are substantially altered compared with the neurologically intact shoulder. The purpose of this study is to report the outcome of shoulder arthroplasty in a group of patients with end-stage arthritis secondary to OBPI. Seven patients with OBPI and secondary glenohumeral arthritis were treated with shoulder arthroplasty between 1976 and 2014. Two underwent hemiarthroplasty (HA), 2 underwent total shoulder arthroplasty (TSA), and 3 underwent reverse shoulder arthroplasty (RSA). One HA was lost to follow-up and was excluded. The remaining 6 patients (mean age, 62.5 years old at the time of surgery) were followed for a minimum of 2 years (mean, 7.5 years; range, 2-13 years) Outcome measures included pain, range of motion, and postoperative modified Neer ratings. Pain improved in all shoulders. Mean forward flexion was unchanged. No shoulders treated with HA/TSA regained forward elevation above 90°, compared with 1 out of the 3 RSAs. External rotation improved from a mean of -10° to 20°. Active internal rotation decreased from L1 to L5. Immediate postoperative radiographs showed either severe posterior or posterosuperior subluxation in all 3 patients treated with nonconstrained implants. Shoulder arthroplasty is an acceptable option to relieve pain in patients with symptomatic shoulder arthritis as a sequel of OBPI. However, range of motion improvements are not expected. Therapeutic V. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Reverse total shoulder glenoid baseplate stability with superior glenoid bone loss.
Martin, Elise J; Duquin, Thomas R; Ehrensberger, Mark T
2017-10-01
Superior wear of the glenoid bone is common in patients with rotator cuff arthropathy. This can become a treatment challenge for patients who require shoulder arthroplasty. In reverse shoulder arthroplasty (RSA), glenoid bone loss may affect the stability of baseplate fixation. The primary purpose of this biomechanical laboratory study was to assess the initial fixation stability of RSA glenosphere baseplates in the presence of variable amounts of superior glenoid bone loss. High-density solid rigid polyurethane foam (30 pounds/cubic foot) was machined to model the glenoid with variable superior defects that provided different levels of support (100%, 90%, 75%, and 50%) for the glenosphere baseplate. The samples were cyclically loaded (0-750 N at 1 Hz for 5000 cycles) at a 60° glenohumeral angle. The micromotion and migration of the baseplate were calculated from displacement data captured during the loading tests with an array of 3 linear variable differential transformers mounted around the baseplate. Micromotion was significantly greater in samples with 50% defects compared with those with smaller defects. Migration was significantly greater after testing for all defect sizes. Initial fixation of RSA glenosphere baseplates was significantly reduced in models with 50% bone loss on the superior edge compared with models with less bone loss in this high-density bone foam model. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Patch-Augmented Rotator Cuff Repair and Superior Capsule Reconstruction
Petri, M.; Greenspoon, J.A.; Moulton, S.G.; Millett, P.J.
2016-01-01
Background: Massive rotator cuff tears in active patients with minimal glenohumeral arthritis remain a particular challenge for the treating surgeon. Methods: A selective literature search was performed and personal surgical experiences are reported. Results: For patients with irreparable rotator cuff tears, a reverse shoulder arthroplasty or a tendon transfer are often performed. However, both procedures have rather high complication rates and debatable long-term results, particularly in younger patients. Therefore, patch-augmented rotator cuff repair or superior capsule reconstruction (SCR) have been recently developed as arthroscopically applicable treatment options, with promising biomechanical and early clinical results. Conclusion: For younger patients with irreparable rotator cuff tears wishing to avoid tendon transfers or reverse total shoulder arthroplasty, both patch-augmentation and SCR represent treatment options that may delay the need for more invasive surgery. PMID:27708733
Ostlie, Kristin; Franklin, Rosemary J; Skjeldal, Ola H; Skrondal, Anders; Magnus, Per
2011-10-01
To describe physical function in adult acquired major upper-limb amputees (ULAs) by combining self-assessed arm function and physical measures obtained by clinical examinations; to estimate associations between background factors and self-assessed arm function in ULAs; and to assess whether clinical examination findings may be used to detect reduced arm function in unilateral ULAs. postal questionnaires and clinical examinations. Norwegian ULA population. Clinical examinations performed at 3 clinics. Questionnaires: population-based sample (n=224; 57.4% response rate). Clinical examinations: combined referred sample and convenience sample of questionnaire responders (n=70; 83.3% of those invited). SURVEY inclusion criteria: adult acquired major upper-limb amputation, resident in Norway, mastering of spoken and written Norwegian. Not applicable. The Disabilities of the Arm, Shoulder and Hand (DASH) Outcome Questionnaire, and clinical examination of joint motion and muscle strength with and without prostheses. Mean DASH score was 22.7 (95% confidence interval [CI], 20.3-25.0); in bilateral amputees, 35.7 (95% CI, 23.0-48.4); and in unilateral amputees, 22.1 (95% CI, 19.8-24.5). A lower unilateral DASH score (better function) was associated with paid employment (vs not in paid employment: adjusted regression coefficient [aB]=-5.40, P=.033; vs students: aB=-13.88, P=.022), increasing postamputation time (aB=-.27, P=.001), and Norwegian ethnicity (aB=-14.45, P<.001). At clinical examination, we found a high frequency of impaired neck mobility and varying frequencies of impaired joint motion and strength at the shoulder, elbow, and forearm level. Prosthesis wear was associated with impaired joint motion in all upper-limb joints (P<.006) and with reduced shoulder abduction strength (P=.002). Impaired without-prosthesis joint motion in shoulder flexion (ipsilateral: aB=12.19, P=.001) and shoulder abduction (ipsilateral: aB=12.01, P=.005; contralateral: aB=28.82, P=.004) was associated with increased DASH scores. Upper-limb loss clearly affects physical function. DASH score limitation profiles may be useful in individual clinical assessments. Targeted clinical examination may indicate patients with extra rehabilitational needs. Such examinations may be of special importance in relation to prosthesis function. Copyright © 2011 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Berhouet, J; Garaud, P; Favard, L
2013-12-01
A common disadvantage of reverse shoulder arthroplasty is limitation of the range of arm rotation. Several changes to the prosthesis design and implantation technique have been suggested to improve rotation range of motion (ROM). Glenoid component design and degree of humeral component retroversion influence rotation ROM after reverse shoulder arthroplasty. The Aequalis Reversed™ shoulder prosthesis (Tornier Inc., Edina, MN, USA) was implanted into 40 cadaver shoulders. Eight glenoid component combinations were tested, five with the 36-mm sphere (centred seating, eccentric seating, inferior tilt, centred with a 5-mm thick lateralised spacer, and centred with a 7-mm thick lateralised spacer) and three with the 42-mm sphere (centred with no spacer or with a 7-mm or 10-mm spacer). Humeral component position was evaluated with 0°, 10°, 20°, 30°, and 40° of retroversion. External and internal rotation ROMs to posterior and anterior impingement on the scapular neck were measured with the arm in 20° of abduction. The large glenosphere (42 mm) was associated with significantly (P<0.05) greater rotation ROMs, particularly when combined with a lateralised spacer (46° internal and 66° external rotation). Rotation ROMs were smallest with the 36-mm sphere. Greater humeral component retroversion was associated with a decrease in internal rotation and a significant increase (P<0.05) in external rotation. The best balance between rotation ROMs was obtained with the native retroversion, which was estimated at 17.5° on average in this study. Our anatomic study in a large number of cadavers involved a detailed and reproducible experimental protocol. However, we did not evaluate the variability in scapular anatomy. Earlier studies of the influence of technical parameters did not take humeral component retroversion into account. In addition, no previous studies assessed rotation ROMs. Rotation ROM should be improved by the use of a large-diameter glenosphere with a spacer to lateralise the centre of rotation of the gleno-humeral joint, as well as by positioning the humeral component at the patient's native retroversion value. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Progressive glenoid bone loss caused by erosion in humeral head resurfacing.
Werner, B S; Stehle, J; Abdelkawi, A; Plumhoff, P; Hudek, R; Gohlke, F
2017-12-01
Cementless surface replacement of the shoulder represents an alternative to conventional stemmed anatomic prostheses. Glenoid erosion is a well-known complication in hemiarthroplasty. However, there is limited data concerning radiographic evaluation and prognostic factors for this phenomenon. The aim of our study was to determine the development of glenoid erosion following shoulder resurfacing using a new measurement technique and detect potential prognostic factors. We performed a retrospective analysis on 38 shoulders undergoing humeral head resurfacing with a mean follow-up of 65.4 ± 43 months. Clinical and radiographic evaluation followed a standardized protocol including pre- and postoperative Constant score, active range of motion, and X‑rays in true anteroposterior view. Three independent observers performed measurements of glenoid erosion. We found good interobserver reliability for glenoid erosion measurements (intraclass correlation coefficient [ICC] 0.74-0.78). Progressive glenoid erosion was present in all cases, averaging 5.5 ± 3.9 mm at more than 5 years' follow-up. Male patients demonstrated increased glenoid bone loss within the first 5 years (p < 0.04). The mean Constant score improved to 55.4 ± 23.6 points at the latest follow-up. Younger age was correlated to increased functional outcome. Revision rate due to painful glenoid erosion was 37%. Glenoid erosion can be routinely expected in patients undergoing humeral head resurfacing. Painful glenoid erosion leads to deterioration in functional outcome and necessitates revision surgery in a high percentage of cases.
Chronic Irreducible Anterior Dislocation of the Shoulder without Significant Functional Deficit.
Chung, Hoejeong; Yoon, Yeo-Seung; Shin, Ji-Soo; Shin, John Junghun; Kim, Doosup
2016-09-01
Shoulder dislocation is frequently encountered by orthopedists, and closed manipulation is often sufficient to treat the injury in an acute setting. Although most dislocations are diagnosed and managed promptly, there are rare cases that are missed or neglected, leading to a chronically dislocated state of the joint. They are usually irreducible and cause considerable pain and functional disability in most affected patients, prompting the need to find a surgical method to reverse the worsening conditions caused by the dislocated joint. However, there are cases of even greater rarity in which chronic shoulder dislocations are asymptomatic with minimal functional or structural degeneration in the joint. These patients are usually left untreated, and most show good tolerance to their condition without developing disabling symptoms or significant functional loss over time. We report on one such patient who had a chronic shoulder dislocation for more than 2 years without receiving treatment.
NASA Astrophysics Data System (ADS)
Kawahara, Toshio; Tabuchi, Norikazu; Arai, Takashi; Sato, Yoshikazu; Morimoto, Jun; Matsumura, Hideki
2005-02-01
We measured structure factors of hydrogenated amorphous Si by x-ray diffraction and analysed the obtained structures using a reverse Monte Carlo (RMC) technique. A small shoulder in the measured structure factor S(Q) was observed on the larger Q side of the first peak. The RMC results with an unconstrained model did not clearly show the small shoulder. Adding constraints for coordination numbers 2 and 3, the small shoulder was reproduced and the agreement with the experimental data became better. The ratio of the constrained coordination numbers was consistent with the ratio of Si-H and Si-H2 bonds which was estimated by the Fourier transformed infrared spectra of the same sample. This shoulder and the oscillation of the corresponding pair distribution function g(r) at large r seem to be related to the low randomness of cat-CVD deposited a-Si:H.
Voorde, Pia C Ten; Rasmussen, Jeppe V; Olsen, Bo S; Brorson, Stig
2015-06-01
There is no consensus on which type of shoulder prosthesis should be used in patients with rheumatoid arthritis (RA). We describe patients with RA who were treated with shoulder replacement, regarding patient-reported outcome, prosthesis survival, and causes of revision, and we compare outcome after resurfacing hemi-arthroplasty (RHA) and stemmed hemi-arthroplasty (SHA). We used data from the national Danish Shoulder Arthroplasty Registry and included patients with RA who underwent shoulder arthroplasty in Denmark between 2006 and 2010. Patient-reported outcome was obtained 1-year postoperatively using the Western Ontario Osteoarthritis of the Shoulder index (WOOS), and rates of revision were calculated by checking revisions reported until December 2011. The patient-reported outcome of RHA was compared to that of SHA using regression analysis with adjustment for age, sex, and previous surgery. During the study period, 167 patients underwent shoulder arthroplasty because of rheumatoid arthritis, 80 (48%) of whom received RHA and 34 (26%) of whom received SHA. 16 patients were treated with total stemmed shoulder arthroplasty (TSA), and 24 were treated with reverse shoulder arthroplasty (rTSA). 130 patients returned a completed questionnaire, and the total mean WOOS score was 63. The cumulative 5-year revision rate was 7%. Most revisions occurred after RHA, with a revision rate of 14%. Mean WOOS score was similar for RHA and for SHA. This study shows that shoulder arthroplasty, regardless of design, is a good option in terms of reducing pain and improving function in RA patients. The high revision rate in the RHA group suggests that other designs may offer better implant survival. However, this should be confirmed in larger studies.
Elwell, Josie; Choi, Joseph; Willing, Ryan
2017-02-08
Lateralizing the center of rotation (COR) of reverse total shoulder arthroplasty (rTSA) could improve functional outcomes and mitigate scapular notching, a commonly occurring complication of the procedure. However, resulting increases in torque at the bone-implant interface may negatively affect initial fixation of the glenoid-side component, especially if only two fixation screws can be placed. Shoulder-specific finite element (FE) models of four fresh-frozen cadaveric shoulders were constructed. Scapular geometry and material property distributions were derived from CT data. Generic baseplates with two and four fixation screws were virtually implanted, after which superiorly-oriented shear loads, accompanied by a compressive load, were applied incrementally further from the glenoid surface to simulate lateralization of the COR. Relationships between lateralization, adduction range of motion (ROM), the number of fixation screws and micromotion of the baseplate (initial implant fixation) were characterized. Lateralization significantly increases micromotion (p=0.015) and adduction ROM (p=0.001). Using two, versus four, baseplate fixation screws significantly increases micromotion (p=0.008). The effect of lateralization and the number of screws on adduction ROM and baseplate fixation is variable on a shoulder-specific basis. Trade-offs exist between functional outcomes, namely adduction ROM, and initial implant fixation and the negative effect of lateralization on implant fixation is amplified when only two fixation screws are used. The possibility of lateralizing the COR in order to improve functional outcomes of the procedure should be considered on a patient-specific basis accounting for factors such as availability and quality of bone stock. Copyright © 2016 Elsevier Ltd. All rights reserved.
Liu, Joseph N; Garcia, Grant H; Mahony, Gregory; Wu, Hao-Hua; Dines, David M; Warren, Russell F; Gulotta, Lawrence V
2016-06-01
Traditionally, fewer postoperative sport restrictions are imposed on hemiarthroplasty (HHA) patients on than reverse total shoulder arthroplasty (RTSA) patients. However, functional outcomes have been shown to be superior in RTSA. No direct comparison of RTSA vs HHA has been done on rates of return to sports in patients with glenohumeral arthritis and rotator cuff dysfunction, proximal humeral fractures, or rheumatoid arthritis. This is a retrospective review of consecutive RTSA and HHA patients collected from our institution's shoulder arthroplasty registry. All patients playing sports preoperatively with minimum 1-year follow-up were included. Final follow-up included an additional patient-reported questionnaire with questions regarding physical fitness and sport activities. The study included 102 RTSA and 71 HHA patients. Average age at surgery was 72.3 years for RTSA compared with 65.6 years for HHA (P < .001). Patients undergoing RTSA had improved visual analog scale scores compared with HHA (-5.6 vs -4.2, P = .007), returned to sports after RTSA at a significantly higher rate (85.9% vs 66.7%, P = .02), and were more likely to be satisfied with their ability to play sports (P = .013). HHA patients were also more likely to have postoperative complaints than RTSA patients (63% vs 29%, P < .0001). No sports-related complications occurred. Female sex, age <70 years, surgery on the dominant extremity, and a preoperative diagnosis of arthritis with rotator cuff dysfunction predicted a higher likelihood of return to sports for patients undergoing RTSA compared with HHA. Despite traditional sport restrictions placed on RTSA, patients undergoing RTSA can return to sports at rates higher than those undergoing HHA, with fewer postoperative complaints. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
[The Bridgelok system for additional retention of bonded prostheses].
Maroto García, J; Gutiérrez Molero, F; López Montero, M V
1989-04-01
The partial protesis with metal carving and cemented with composite resin is used frequently as a reversible method in order to substitute teeth, due to the light preparation necessary for the original teeth. Recently, a new system (Bridgelok) with pins has been proposed as safer for this kind of protesis. This paper studies if this new system originates a higher resistance compared to other system without pins.
De Santis, Roberto; Gloria, Antonio; Russo, Teresa; D'Amora, Ugo; Varriale, Angelo; Veltri, Mario; Balleri, Piero; Mollica, Francesco; Riccitiello, Francesco; Ambrosio, Luigi
2014-12-18
This study aimed at investigating the effects of titanium implants and different configurations of full-arch prostheses on the biomechanics of edentulous mandibles. Reverse engineered, composite, anisotropic, edentulous mandibles made of a poly(methylmethacrylate) core and a glass fibre reinforced outer shell were rapid prototyped and instrumented with strain gauges. Brånemark implants RP platforms in conjunction with titanium Procera one-piece or two-piece bridges were used to simulate oral rehabilitations. A lateral load through the gonion regions was used to test the biomechanical effects of the rehabilitations. In addition, strains due to misfit of the one-piece titanium bridge were compared to those produced by one-piece cast gold bridges. Milled titanium bridges had a better fit than cast gold bridges. The stress distribution in mandibular bone rehabilitated with a one-piece bridge was more perturbed than that observed with a two-piece bridge. In particular the former induced a stress concentration and stress shielding in the molar and symphysis regions, while for the latter design these stresses were strongly reduced. In conclusion, prosthetic frameworks changed the biomechanics of the mandible as a result of both their design and manufacturing technology. Copyright © 2014 Elsevier Ltd. All rights reserved.
Osinga, R; Mazzone, L; Meuli, M; Meuli-Simmen, C; von Campe, A
2014-08-01
The latissimus dorsi flap (LDF) has been employed very successfully over decades to cover large soft-tissue defects. Its donor-site morbidity has been extensively investigated in adults - but not in children - and is considered to be nonrestrictive. The aim of this long-term study was to assess donor-site morbidity with the modified Constant score more than 8 years after coverage of large myelomeningocele (MMC) defects with a reverse latissimus dorsi flap. Within the first days after birth, the reverse latissimus dorsi muscle flap was used uni- or bilaterally in three neonates to cover a large MMC defect. Bilateral shoulder function was tested more than 8 years postoperatively according to the modified Constant score. The mean age at follow-up was 11.7 years. None of the patients experienced any pain or shoulder restrictions during normal daily activities. They all managed to position both of their arms comfortably above the head. Forward flexion was normal in all patients as was abduction and external rotation. Dorsal extension was minimally reduced on the operated side. Internal rotation was symmetric in all patients; the extent of active movement varied from excellent to poor. Our long-term data suggest that there is no specific and significant impairment of shoulder function after using the distally pedicled reverse LDF for neonatal MMC repair. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Aoyagi, Yoichiro; Tsubahara, Akio
2004-01-01
Upper extremity hemiplegia after stroke is common and disabling. Apart from conventional physical and occupational therapy, a number of additional approaches that use devices such as orthoses, prostheses, electrical stimulation, and robots have been introduced. The purpose of this review was to assess the clinical efficacy of such devices used for the affected upper extremities of acute, subacute, and chronic stroke patients. Assessments of their effectiveness and recommendations were based on the weight of published scientific evidence. The amount of evidence with respect to hand splints and shoulder slings is limited. Further study with a well-designed randomized controlled trial (RCT) is required to investigate accurately their short- and long-term efficacy. A number of studies suggested that the use of electrical stimulation for reducing shoulder subluxation or improving the function of wrist and finger extensors is effective during or shortly after the daily treatment period. The robotic approach to hemiplegic upper extremities appears to be a novel therapeutic strategy that may help improve hand and arm function. However, the longer term effectiveness after discontinuation as well as the motor recovery mechanism of electrical stimulation or robotic devices remains unclear. More research is needed to determine the evidence-based effectiveness of electrical stimulation or other devices for stroke survivors.
Outcomes and Costs of Reverse Shoulder Arthroplasty in the Morbidly Obese: A Case Control Study.
Pappou, Ioannis; Virani, Nazeem A; Clark, Rachel; Cottrell, Benjamin J; Frankle, Mark A
2014-07-16
The rising number of morbidly obese patients has important consequences for the health-care system. We investigated the effect of morbid obesity on outcomes, complications, discharge disposition, and costs in patients undergoing reverse shoulder arthroplasty. Our joint registry was searched for all patients who had undergone primary reverse shoulder arthroplasty for a reason other than fracture from 2003 to 2010 and had a minimum of twenty-four months of follow-up. Twenty-one patients with a body mass index (BMI) of ≥40 kg/m 2 were identified (follow-up, 45 ± 16 months; sex, seventeen female and four male; age, 69 ± 7 years) and were compared with sixty-three matched control patients with a BMI of <30 kg/m 2 (follow-up, 48 ± 20 months; sex, fifty female and thirteen male; age, 71 ± 6 years) after an a priori sample size calculation. Outcome instrument data were obtained preoperatively and postoperatively. The Charlson-Deyo comorbidity index (CDI) score, total comorbidities, operative time, blood loss, duration of hospital stay, discharge disposition, costs, and complications were recorded. Compared with nonobese patients, morbidly obese patients had similar improvements in functional outcomes (e.g., American Shoulder and Elbow Surgeons score, 32 to 69 compared with 40 to 78) and in shoulder motion (e.g., forward flexion, 61° to 140° compared with 74° to 153°); all improvements were significant (p < 0.05). Morbidly obese patients had a similar rate of scapular notching (odds ratio [OR] = 0.58, p = 0.63), more total comorbidities excluding obesity (six compared with four, p = 0.001), a higher CDI (2 compared with 1, p = 0.025), and a higher rate of obstructive sleep apnea (OR = 27.7, p = 0.0001). Their operative time was thirteen minutes longer (p = 0.014) and their blood loss was 40 mL greater (p = 0.008). Morbidly obese patients had a similar duration of stay (3.1 compared with 2.6 days, p = 0.823) and hospital readmission rate (OR = 16.3, p = 0.08) but a sixfold higher rate of discharge to rehabilitation facilities rather than to home (OR = 8, p < 0.0001). Hospital costs were higher by $2974 (p = 0.009). The rates of major complications (n = 4 compared with 8, p = 0.479) and of minor complications (n = 3 compared with 14, p = 0.440) were similar. No intraoperative complications or mechanical device failures were noted in either group. Reverse shoulder arthroplasty appears to be as safe and effective in morbidly obese patients, although it has an increased cost and patients have a lower rate of discharge to home and greater care needs after discharge. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.
Cemented or cementless humeral fixation in reverse total shoulder arthroplasty? a systematic review.
Phadnis, J; Huang, T; Watts, A; Krishnan, J; Bain, G I
2016-01-01
To date, there is insufficient evidence available to compare the outcome of cemented and uncemented fixation of the humeral stem in reverse shoulder arthroplasty (RSA). A systemic review comprising 41 clinical studies was performed to compare the functional outcome and rate of complications of cemented and uncemented stems in RSA. These included 1455 cemented and 329 uncemented shoulders. The clinical characteristics of the two groups were similar. Variables were compared using pooled frequency-weighted means and relative risk ratios (RR). Uncemented stems had a significantly higher incidence of early humeral stem migration (p < 0.001, RR 18.1, 95% confidence interval (CI) 5.0 to 65.2) and non-progressive radiolucent lines (p < 0.001, RR 2.4, 95% CI 1.7 to 3.4), but a significantly lower incidence of post-operative fractures of the acromion compared with cemented stems (p = 0.004, RR 14.3, 95% CI 0.9 to 232.8). There was no difference in the risk of stem loosening or revision between the groups. The cemented stems had a greater relative risk of infection (RR 3.3, 95% CI 0.8 to 13.7), nerve injury (RR 5.7, 95% CI 0.7 to 41.5) and thromboembolism (RR 3.9, 95% CI 0.2 to 66.6). The functional outcome and range of movement were equivalent in the two groups. RSA performed with an uncemented stem gives them equivalent functional outcome and a better complication profile than with a cemented stem. The natural history and clinical relevance of early stem migration and radiolucent lines found with uncemented stems requires further long-term study. This study demonstrates that uncemented stems have at least equivalent clinical and radiographic outcomes compared with cemented stems when used for reverse total shoulder arthroplasty. ©2016 The British Editorial Society of Bone & Joint Surgery.
Analysis of a retrieved delta III total shoulder prosthesis.
Nyffeler, R W; Werner, C M L; Simmen, B R; Gerber, C
2004-11-01
A reversed Delta III total shoulder prosthesis was retrieved post-mortem, eight months after implantation. A significant notch was evident at the inferior pole of the scapular neck which extended beyond the inferior fixation screw. This bone loss was associated with a corresponding, erosive defect of the polyethylene cup. Histological examination revealed a chronic foreign-body reaction in the joint capsule. There were, however, no histological signs of loosening of the glenoid base plate and the stability of the prosthetic articulation was only slightly reduced by the eroded rim of the cup.
Kim, Hyun-Min Mike; Chacon, Alexander C; Andrews, Seth H; Roush, Evan P; Cho, Edward; Conaway, William K; Kunselman, Allen R; Lewis, Gregory S
2016-04-01
Restoration of joint stability during total shoulder arthroplasty can be challenging in the face of severe glenoid retroversion. A novel technique of humeral head component anterior-offsetting has been proposed to address posterior instability. We evaluated the biomechanical benefits of this technique in cadaveric specimens. Total shoulder arthroplasty was performed in 14 cadaveric shoulders from 7 donors. Complementary shoulders were assigned to either 10° or 20° glenoid retroversion, with retroversion created by eccentric reaming. Two humeral head component offset positions were tested in each specimen: The anatomic (posterior) and anterior (reverse). With loads applied to the rotator cuff and deltoid, joint contact pressures and the force and energy required for posterior humeral head translation were measured. The force and energy required to displace the humeral head posteriorly increased significantly with the anterior offset position compared to the anatomic offset position. The joint contact pressures were significantly shifted anteriorly, and the joint contact area significantly increased with the anterior offset position. Anterior offsetting of the humeral head component increased the resistance to posterior humeral head translation, shifted joint contact pressures anteriorly, and increased joint contact area, thus, potentially increasing the joint stability in total shoulder arthroplasty with simulated glenoid retroversion. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Return to sport after shoulder arthroplasty: a systematic review and meta-analysis.
Liu, Joseph N; Steinhaus, Michael E; Garcia, Grant H; Chang, Brenda; Fields, Kara; Dines, David M; Warren, Russell F; Gulotta, Lawrence V
2018-01-01
With increasing incidence and indications for shoulder arthroplasty, there is an increasing emphasis on the ability to return to sports. The main goal of this study was to determine the rate of return to sport after shoulder arthroplasty. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were followed to perform this systematic review and meta-analysis. A search was performed on MEDLINE, Scopus, EMBASE, and the Cochrane Library. The quality of the included studies was evaluated according to the Methodological Index for Nonrandomized Studies checklist. The main judgement outcome was the rate of return to sports activity after shoulder arthroplasty and the level of play upon return (identical or higher/lower level). Thirteen studies were reviewed, including 944 patients (506 athletes), treated with shoulder arthroplasty at an average follow-up of 5.1 years (range, 0.5-12.6 years). The most common sports were swimming (n = 169), golf (n = 144), fitness sports (n = 71), and tennis (n = 63). The overall rate of return to sport was 85.1% (95% CI, 76.5-92.3%), including 72.3% (95% CI, 60.6-82.8%) returning to an equivalent or improved level of play, after 1-36 months. Patients undergoing anatomic total shoulder arthroplasty returned at a significantly higher rate (92.6%) compared to hemiarthroplasty (71.1%, p = 0.02) or reverse total shoulder arthroplasty (74.9%, p = 0.003). Most patients are able to return to one or more sports following shoulder arthroplasty, with anatomic total shoulder arthroplasty having the highest rate of return. IV.
Chae, Soo-Won; Kim, Soung-Yon; Lee, Haea; Yon, Joung-Ro; Lee, Juneyoung; Han, Seung-Ho
2014-12-09
Use of a baseplate with a smaller diameter in reverse shoulder arthroplasty is increasing, especially in patients with a small glenoid or glenoid wear. However, the effect of a smaller baseplate on stability of the glenoid component has not been evaluated. Thus, the purpose of this study was to determine whether a smaller baseplate (25 mm) is beneficial to the initial stability of the glenoid component compared to that with a baseplate of a commonly used size (29 mm). Micromotion of glenoid components attached to 14 scapulae of fresh-frozen cadavers was measured and compared between 25- and 29-mm baseplates in biomechanical testing. Impingement-free range of motion in abduction, adduction, internal rotation, and external rotation was evaluated by using a simulated computer model constructed based on the same fresh-frozen cadavers used in biomechanical testing. Micromotion at the inferior third of the glenoid-glenosphere interface was higher in the 29-mm baseplate group than in the 25-mm baseplate group during both 0.7- and 1-body weight cyclic loading in biomechanical testing. Adduction deficit was smaller, and total impingement-free range of motion from abduction to adduction and rotation were greater in the 25-mm baseplate group than in the 29-mm baseplate group in the simulated computer model. Use of a baseplate with a smaller diameter (25 mm) in reverse shoulder arthroplasty is suitable for improving the primary stability of the glenoid component. With a smaller baseplate, impingement-free range of motion is optimized in a smaller glenoid.
Vincent, Heather K; Struk, Aimee M; Reed, Austin; Wright, Thomas W
2016-01-01
Shoulder pain and loss of function are directly associated with obesity. We hypothesized that significant interactions would exist between total shoulder arthroplasty (TSA) and reverse total shoulder arthroplasty (RSA) and obesity status on functional and quality of life (QOL) outcomes over the long term. Clinical and QOL outcomes (American Shoulder and Elbow Surgeons Evaluation form, Shoulder Pain and Disability Index, University of California at Los Angeles Shoulder Rating scale, Medical Outcomes Short Form 12 (SF-12), range of motion (ROM), and strength) were longitudinally compared in patients with low and high body mass index (BMI) after a TSA or a RSA. Prospectively collected data of patients with a TSA or RSA were reviewed (N = 310). Preoperative, 2-year, and final follow-up visits were included (range 3-17 years; mean 5.0 ± 2.5 years). Patient data were stratified for analysis using BMI. Morbidly obese patients had worse preoperative functional scores and QOL compared to the other groups. There were no significant interactions of BMI group by surgery type for any of the outcome variables except for active external rotation ROM. Morbidly obese patients attained lower SF-12 scores compared to the remaining groups at each time point. Both TSA and RSA can be expected to impart positive functional outcomes in patients irrespective of BMI. Morbidly obese patients do not attain the same gains in Medical Outcomes SF-12 scores as the non-morbidly obese patients. The lower improvements in active external ROM may be due to morphological limitations of excessive adiposity. This is a level II study.
Shoulder dystocia and associated manoeuvres as risk factors for perineal trauma.
Gauthaman, Nivedita; Walters, Samuel; Tribe, In-Ae; Goldsmith, Louise; Doumouchtsis, Stergios K
2016-04-01
Shoulder dystocia (SD) is an obstetric emergency that can be associated with serious neonatal morbidity and mortality. The aim of this study was to identify the incidence and risk factors for obstetric anal sphincter injuries (OASIS) in women who sustained SD at birth. This was a retrospective observational study over a 5-year period whereby 403 cases of SD were identified. The primary outcome measure was to identify the incidence of OASIS in women with SD. We also evaluated the role of the manoeuvres used for the management of SD and aimed to identify possible correlations between specific manoeuvres and OASIS by univariate and multivariate regression analysis. Shoulder dystocia was associated with a three-fold increase in the risk of OASIS in our population. The use of internal manoeuvres (OR 2.182: 95 % CI 1.173-4.059), an increased number of manoeuvres ≥ 4 (OR 4.667: 95 % CI 1.846-11.795), Woods' screw manoeuvre (OR 3.096: 95 % CI 1.554-6.169), reverse Woods' screw manoeuvre (OR 4.848: 95 % CI 1.647-14.277) and removal of the posterior arm (OR 2.222: 95 % CI 1.117-4.421) were all associated with a significant increase in the likelihood of OASIS. In our study, instrumental deliveries, the use of internal manoeuvres (Woods' screw and reverse Woods' screw) and four or more manoeuvres for the management of SD were independently associated with a higher incidence of OASIS. To effectively manage shoulder dystocia with lower risks of perineal trauma, these factors could be considered when designing further prospective studies and developing management protocols.
Langohr, G Daniel G; Giles, Joshua W; Athwal, George S; Johnson, James A
2015-06-01
Little is known about the effects of glenosphere diameter on shoulder joint loads. The purpose of this biomechanical study was to investigate the effects of glenosphere diameter on joint load, load angle, and total deltoid force required for active abduction and range of motion in internal/external rotation and abduction. A custom, instrumented reverse shoulder arthroplasty implant system capable of measuring joint load and varying glenosphere diameter (38 and 42 mm) and glenoid offset (neutral and lateral) was implanted in 6 cadaveric shoulders to provide at least 80% power for all variables. A shoulder motion simulator was used to produce active glenohumeral and scapulothoracic motion. All implant configurations were tested with active and passive motion with joint kinematics, loads, and moments recorded. At neutral and lateralized glenosphere positions, increasing diameter significantly increased joint load (+12 ± 21 N and +6 ± 9 N; P < .01) and deltoid load required for active abduction (+9 ± 22 N and +11 ± 15 N; P < .02), whereas joint load angle was unaffected (P > .8). Passive internal rotation was reduced with increased diameter at both neutral and lateralized glenosphere positions (-6° ± 6° and -12° ± 6°; P < .002); however, external rotation was not affected (P > .05). At neutral glenosphere position, increasing diameter increased the maximum angles of both adduction (+1° ± 1°; P = .03) and abduction (+8° ± 9°; P < .05). Lateralization also increased abduction range of motion compared with neutral (P < .01). Although increasing glenosphere diameter significantly increased joint load and deltoid force, the clinical impact of these changes is presently unclear. Internal rotation, however, was reduced, which contradicts previous bone modeling studies, which we postulate is due to increased posterior capsular tension as it is forced to wrap around a larger 42 mm implant assembly. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Arthroscopic management of posterior instability: evolution of technique and results.
Savoie, Felix H; Holt, M Shaun; Field, Larry D; Ramsey, J Randall
2008-04-01
The purpose of this study was to evaluate the effectiveness of arthroscopic posterior shoulder reconstruction. We treated 136 shoulders in 131 patients with a diagnosis of primary posterior instability who failed 6 months of vigorous rehabilitation by operative stabilization between 1989 and 2001. Inclusion criterion was primary posterior instability that failed an extensive rehabilitative program with functional impairment and pain. Exclusion criterion was less than 12 months of follow-up and Suretac (Smith & Nephew, Andover, MA) or laser stabilization, leaving 92 shoulders in 90 patients available for the study (69 male, 21 female). Follow-up ranged from 12 to 132 months (average, 28 months). Each patient underwent diagnostic arthroscopy and surgical repair at the same time using one of several primary procedures. The procedure used was based on the pathologic entity noted at the time of surgery. At an average follow-up of 28 months, 97% of the shoulders were stable and considered a success based on the Neer-Foster rating scale. Posterior pathology varied, and a reverse Bankart lesion alone was found 51% of the time, a stretched posterior capsule 67% of the time, and a combination of a reverse Bankart lesion and capsular stretching 16% of the time. The rotator interval was obviously damaged in 61% of cases. Multiple accompanying lesions were found, including anterior-superior labral tears and SLAP tears (20%), superior glenohumeral ligament injury (7%), middle glenohumeral ligament injury (38%), anteroinferior glenohumaral ligament injury (37%), and an enlarged axillary pouch (20%). No essential lesion is present for posterior instability. Multiple varied pathologies will be present in a shoulder presenting with posterior instability. Arthroscopic surgery allows inspection of the joint and anatomic-specific repairs based on pathology. Careful attention to all the supporting structures of the shoulder, including the rotator interval, the anterior-superior labrum, and its attached superior glenohumeral ligament, the coracohumeral ligament, the inferior glenohumeral ligament complex, and the infraspinatus, in addition to the posterior labrum and capsule, allows excellent outcomes to be achieved with arthroscopic posterior reconstruction techniques. Level IV, therapeutic case series.
Merolla, Giovanni; Tartarone, Antonio; Sperling, John W; Paladini, Paolo; Fabbri, Elisabetta; Porcellini, Giuseppe
2017-01-01
The aim of this study was to assess the effectiveness of reverse total shoulder arthroplasty (RTSA) with an all-polyethylene glenosphere in patients with failed hemiarthroplasty (HH) or the sequelae of proximal humeral fractures. Thirty-six patients were assessed at a mean follow-up of 36 months using clinical scores and recording shoulder range of movement (ROM). Active anterior elevation (p < 0.001), lateral elevation (p < 0.001) and internal rotation (p < 0.0001) improved significantly, whereas improvement in external rotation was not significant. The mean Constant score rose significantly from 8.5 ± 7.6 to 40.7 ± 15.7 (p < 0.001) and the Simple Shoulder Test score from 0.42 ± 0.85 to 5.5 ± 2.6 (p < 0.001). Pain improved significantly from 8.7 ± 0.9 to 2.3 ± 1.2 (p < 0.001). Implant radiographic survivorship was 84.6 %. Scapular notching was detected in 7/36 patients (17.5 %). There were five complications: one (stiffness) among patients with fracture sequelae and four among those with failed HH (instability, n = 2; humeral component disassembly, n = 1; pain, n = 1). The two groups did not exhibit significant differences in pain, clinical scores or ROM. RTSA with an all-polyethylene glenosphere may have the potential to reduce the risk of biological notching due to polyethylene osteolysis. Further long-term studies are required to assess its efficacy. The good clinical performance and reasonable rate of notching of the polyethylene glenosphere support its use in primary and revision shoulder arthroplasty. Level 4, retrospective therapeutic case series.
The Development of a Myoelectric Training Tool for Above-Elbow Amputees
Dawson, Michael R; Fahimi, Farbod; Carey, Jason P
2012-01-01
The objective of above-elbow myoelectric prostheses is to reestablish the functionality of missing limbs and increase the quality of life of amputees. By using electromyography (EMG) electrodes attached to the surface of the skin, amputees are able to control motors in myoelectric prostheses by voluntarily contracting the muscles of their residual limb. This work describes the development of an inexpensive myoelectric training tool (MTT) designed to help upper limb amputees learn how to use myoelectric technology in advance of receiving their actual myoelectric prosthesis. The training tool consists of a physical and simulated robotic arm, signal acquisition hardware, controller software, and a graphical user interface. The MTT improves over earlier training systems by allowing a targeted muscle reinnervation (TMR) patient to control up to two degrees of freedom simultaneously. The training tool has also been designed to function as a research prototype for novel myoelectric controllers. A preliminary experiment was performed in order to evaluate the effectiveness of the MTT as a learning tool and to identify any issues with the system. Five able-bodied participants performed a motor-learning task using the EMG controlled robotic arm with the goal of moving five balls from one box to another as quickly as possible. The results indicate that the subjects improved their skill in myoelectric control over the course of the trials. A usability survey was administered to the subjects after their trials. Results from the survey showed that the shoulder degree of freedom was the most difficult to control. PMID:22383905
The development of a myoelectric training tool for above-elbow amputees.
Dawson, Michael R; Fahimi, Farbod; Carey, Jason P
2012-01-01
The objective of above-elbow myoelectric prostheses is to reestablish the functionality of missing limbs and increase the quality of life of amputees. By using electromyography (EMG) electrodes attached to the surface of the skin, amputees are able to control motors in myoelectric prostheses by voluntarily contracting the muscles of their residual limb. This work describes the development of an inexpensive myoelectric training tool (MTT) designed to help upper limb amputees learn how to use myoelectric technology in advance of receiving their actual myoelectric prosthesis. The training tool consists of a physical and simulated robotic arm, signal acquisition hardware, controller software, and a graphical user interface. The MTT improves over earlier training systems by allowing a targeted muscle reinnervation (TMR) patient to control up to two degrees of freedom simultaneously. The training tool has also been designed to function as a research prototype for novel myoelectric controllers. A preliminary experiment was performed in order to evaluate the effectiveness of the MTT as a learning tool and to identify any issues with the system. Five able-bodied participants performed a motor-learning task using the EMG controlled robotic arm with the goal of moving five balls from one box to another as quickly as possible. The results indicate that the subjects improved their skill in myoelectric control over the course of the trials. A usability survey was administered to the subjects after their trials. Results from the survey showed that the shoulder degree of freedom was the most difficult to control.
Utility of polymer cerclage cables in revision shoulder arthroplasty.
Edwards, T Bradley; Stuart, Kyle D; Trappey, George J; O'Connor, Daniel P; Sarin, Vineet K
2011-04-11
Revision shoulder arthroplasty often requires humeral osteotomy for stem extraction or is complicated by periprosthetic fracture. In these situations, various modes of fixation are used, including cerclage wires, cable plates, and allograft strut augmentation. The use of metal wires and cables, however, has been associated with soft tissue irritation, sharps injuries, and accelerated wear of joint arthroplasty bearing surfaces. As an alternative to traditional metal cables, the SuperCable (Kinamed Inc, Camarillo, California) contains braided ultra-high molecular-weight polyethylene fibers surrounding a nylon core. To date, no studies have examined the use of nonmetallic cerclage cables in shoulder arthroplasty.A retrospective review was performed of 11 patients who underwent shoulder arthroplasty for which nonmetallic cerclage cables were used. Clinical and radiographic data were examined regarding patient age, procedure performed, indication for cerclage cabling, time to healing of osteotomy or fracture, and any complications associated with the use of these cerclage cables. Minimum follow-up was 1 year. Ten patients underwent reverse total shoulder arthroplasty, and 1 patient underwent revision unconstrained total shoulder arthroplasty. Mean follow-up was 20.5 months. Ten patients required humeral osteotomy for stem or cement removal. Allograft augmentation was performed in 7 patients. Mean time to healing was 3.2 months. No patients experienced loosening or migration of hardware or allograft, and no complications directly related to the use of nonmetallic cerclage cables were identified. Copyright 2011, SLACK Incorporated.
The effect of bone growth onto massive prostheses collars in protecting the implant from fracture.
Fromme, Paul; Blunn, Gordon W; Aston, William J; Abdoola, Tasneem; Koris, Jacob; Coathup, Melanie J
2017-03-01
Limb-sparing distal femoral endoprotheses used in cancer patients have a high risk of aseptic loosening. It had been reported that young adolescent patients have a higher rate of loosening and fatigue fracture of intramedullary stems because the implant becomes undersized as patients grow. Extracortical bone growth into the grooved hydroxyapatite-coated collar had been shown to reduce failure rates. The stresses in the implant and femur have been calculated from Finite Element models for different stages of bone growth onto the collar. For a small diameter stem without any bone growth, a large stress concentration at the implant shoulder was found, leading to a significant fracture risk under normal walking loads. Bone growth and osseointergration onto the implant collar reduced the stress level in the implant to safe levels. For small bone bridges a risk of bone fracture was observed. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Sheth, Mihir M; Sholder, Daniel; Abboud, Joseph; Lazarus, Mark D; Ramsey, Matthew L; Williams, Gerald R; Namdari, Surena
2018-05-10
The impending burden of revision shoulder arthroplasty has increased interest in outcomes of revision procedures. Painful glenoid arthrosis following hemiarthroplasty is a common cause of reoperation, and conversion to anatomic total shoulder arthroplasty is one option. We identified patients who underwent revision of painful hemiarthroplasty to total shoulder arthroplasty over a 15-year period in a single tertiary-care health system. Presurgical and operative data were analyzed for 28 patients who met the inclusion and exclusion criteria. Patients were contacted at a minimum of 2 years' follow-up after revision surgery for functional outcome scores, reoperations, and implant survival. The 2- and 5-year implant survival rates were 93% and 86%, respectively. Functional outcomes were obtained from 21 patients with surviving implants. The mean American Shoulder and Elbow Surgeons score, visual analog scale score for pain, and Single Assessment Numerical Evaluation score were 78 ± 20, 2.3 ± 2.6, and 71 ± 24, respectively. The mean Short Form 12 mental and physical scores were 49 ± 10 and 43 ± 9, respectively. Of the patients, 17 (81%) were either satisfied or very satisfied with their outcome. Complications were seen in 10 patients (36%), and 6 patients (21%) required reoperation. Anatomic total shoulder arthroplasty following hemiarthroplasty can achieve successful outcomes and implant survival rates. Given our poor understanding of reverse shoulder arthroplasty longevity, this procedure should remain an option for patients with glenoid arthrosis and an intact rotator cuff. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Inter and intra-system size variability of reverse shoulder arthroplasty polyethylene inserts
Teeter, Matthew G.; Dawson, Matthew T.; Athwal, George S.
2016-01-01
Background: As the incidence of reverse shoulder arthroplasty (RSA) increases, so will the revision burden. At times, the revision surgeon may be faced with a well-fixed component on one side of the joint and revision implants from a different manufacturer. The ability to use glenoid and humeral implants from different manufacturers could simplify the revision procedure. This study hypothesized that across a range of RSA systems, some implants would demonstrate high size compatibility and others would demonstrate low compatibility. Materials and Methods: Six polyethylene inserts each from eight reverse total shoulder arthroplasty systems were examined (48 total inserts). All inserts were scanned using a laboratory micro-computed tomography scanner at 50 μm isotropic voxel spacing, and their surface geometries were reconstructed. The different implant geometries were co-registered, and the three-dimensional (3D) variability between the articular surfaces of the different implant systems was measured. Intrasystem manufacturing variability was also determined by measuring the 3D variability of inserts from the same system. Results: The intersystem polyethylene articular surface deviations between same-size systems were not significantly different (P = 0.61) and were a mean maximum of 60 ± 16 μm (range: 30-80 μm). Intrasystem manufacturing variability was equivalent between all but two models, averaging 49 ± 17 μm (range: 23-99 μm). Discussion: Differences in articular geometry between same-size inserts from different systems were on the same scale as intrasystem manufacturing variability, suggesting that different implant systems of the same nominal diameter could potentially be used interchangeably in revision or extenuating circumstances. Conclusion: The results of this study suggest that surgeons can theoretically interchange same-sized implant components from the different RSA systems tested when conducting revisions. PMID:26980984
Abdelfattah, Adham; Otto, Randall J; Simon, Peter; Christmas, Kaitlyn N; Tanner, Gregory; LaMartina, Joey; Levy, Jonathan C; Cuff, Derek J; Mighell, Mark A; Frankle, Mark A
2018-04-01
Revision of unstable reverse shoulder arthroplasty (RSA) remains a significant challenge. The purpose of this study was to determine the reliability of a new treatment-guiding classification for instability after RSA, to describe the clinical outcomes of patients stabilized operatively, and to identify those with higher risk of recurrence. All patients undergoing revision for instability after RSA were identified at our institution. Demographic, clinical, radiographic, and intraoperative data were collected. A classification was developed using all identified causes of instability after RSA and allocating them to 1 of 3 defined treatment-guiding categories. Eight surgeons reviewed all data and applied the classification scheme to each case. Interobserver and intraobserver reliability was used to evaluate the classification scheme. Preoperative clinical outcomes were compared with final follow-up in stabilized shoulders. Forty-three revision cases in 34 patients met the inclusion for study. Five patients remained unstable after revision. Persistent instability most commonly occurred in persistent deltoid dysfunction and postoperative acromial fractures but also in 1 case of soft tissue impingement. Twenty-one patients remained stable at minimum 2 years of follow-up and had significant improvement of clinical outcome scores and range of motion. Reliability of the classification scheme showed substantial and almost perfect interobserver and intraobserver agreement among all the participants (κ = 0.699 and κ = 0.851, respectively). Instability after RSA can be successfully treated with revision surgery using the reliable treatment-guiding classification scheme presented herein. However, more understanding is needed for patients with greater risk of recurrent instability after revision surgery. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Harmsen, Samuel M; Norris, Tom R
2017-09-01
Press-fit humeral fixation in reverse shoulder arthroplasty (RSA) has become increasingly popular; however, radiographic analysis of these stems is limited. We aimed to evaluate the radiographic and clinical outcomes of an adjustable diaphyseal press-fit humeral stem in primary RSA. We conducted a retrospective review of 232 primary RSAs in 219 patients performed by a single surgeon using this system. Radiographic outcomes were evaluated in patients with at least 2 years of radiographic follow-up. Standardized postoperative digital radiographs were analyzed for loosening, osteolysis, and stress shielding. Clinical outcomes in patients who also had complete clinical data sets were evaluated at the most recent follow-up. Radiographic evidence of loosening was identified in 1 RSA (0.4%) associated with deep infection. Aseptic loosening was not observed. No stems were identified as being at high risk for loosening. Internal stress shielding was observed proximal to the coated diaphyseal component in 226 shoulders (97.4%). This finding was often visible at 3 months (92.7%) and predictably progressed on subsequent radiographs. Progression beyond the 2-year period was rarely seen (4.4%). No external stress shielding or osteolysis was observed. Thirty-six complications occurred in 33 patients (15.1%). At an average follow-up of 36.6 months, significant improvements were identified in all measured clinical outcomes (P < .001). Predictable fixation is achieved using an adjustable diaphyseal press-fit humeral system in primary RSA. Internal stress shielding is commonly observed but does not appear to compromise quality of fixation or clinical outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Müller, Andreas M; Born, Marian; Jung, Christian; Flury, Matthias; Kolling, Christoph; Schwyzer, Hans-Kaspar; Audigé, Laurent
2018-01-01
The role of glenosphere size in reverse shoulder arthroplasty (RSA) may be important in prosthetic stability, joint kinematics, rotator cuff tension and excursion, scapular impingement, humeral lateralization, deltoid wrap, and the occurrence of "notching." This study compared short- and midterm clinical and radiographic outcomes for 2 different glenosphere sizes of a single RSA type with respect to implant positioning, glenoid size, and morphology. This retrospective analysis included 68 RSA procedures that were prospectively documented in a local register during a 5-year postoperative period. Two glenosphere diameter sizes of 36 mm (n = 33) and 44 mm (n = 35) were used. Standard radiographs were made preoperatively (ie, baseline) and at 6, 12, 24, and 60 months after surgery. Range of motion, strength, the Constant-Murley score, and the Shoulder Pain and Disability Index were also assessed at all follow-up visits. The effect of glenosphere size on measured outcomes was adjusted for baseline values, patient gender, and humeral head diameter. No significant differences were found in the functional scores between treatment groups at all follow-up assessments. At the 12-month follow-up, patients with a 44-mm glenosphere had greater external rotation in adduction (mean difference, 12°; P = .001) and abduction strength (mean difference, 1.4 kg; P = .026) compared with those with the smaller implant. These differences remained at 60 months. Scapular notching was observed in 38% of all patients, without any relevant difference between the groups. An increase in glenosphere diameter leads to a clinically moderate but significant increase in external rotation in adduction and abduction strength at midterm follow-up. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Yang, Yuhui; Zuo, Jianlin; Liu, Tong; Shao, Pu; Wu, Haihe; Gao, Zhongli; Xiao, Jianlin
2018-03-01
The purpose of this study was to investigate glenoid morphology and define the safe zone for protecting the suprascapular nerve baseplate screw during baseplate fixation in reverse shoulder arthroplasty (RSA) in a Chinese population. Shoulder computed tomography (CT) scans from 56 subjects were retrospectively reviewed. Three-dimensional (3D) reconstruction was performed using Mimics software, and corresponding bony references were used to evaluate glenoid morphology. To standardize evaluation, the coronal scapular plane was defined. Safe fixation distances and screw placements were investigated by constructing a simulated cutting plane of the baseplate during RSA. Mean glenoid height was 35.83 ± 2.95 mm, and width was 27.32 ± 2.78 mm, with significant sexual dimorphism (p < 0.01). According to the cutting plane morphology, the average baseplate radius was 13.84 ± 1.34 mm. The distances from the suprascapular notch and from two bony reference points at the base of the scapular spine to the cutting plane were 30.27 ± 2.77 mm, 18.39 ± 1.67 mm and 16.52 ± 1.52 mm, respectively, with a gender-related difference. Based on the clock face indication system, the danger zone caused by the suprascapular nerve projection was oriented between the two o'clock and eight o'clock positions in reference to the right shoulder. Glenoid size and the safe zone for screw fixation during RSA were characterized in a Chinese population. Careful consideration of baseplate fixation and avoidance of suprascapular nerve injury are important for improved clinical outcome.
Venne, Gabriel; Rasquinha, Brian J; Pichora, David; Ellis, Randy E; Bicknell, Ryan
2015-07-01
Preoperative planning and intraoperative navigation technologies have each been shown separately to be beneficial for optimizing screw and baseplate positioning in reverse shoulder arthroplasty (RSA) but to date have not been combined. This study describes development of a system for performing computer-assisted RSA glenoid baseplate and screw placement, including preoperative planning, intraoperative navigation, and postoperative evaluation, and compares this system with a conventional approach. We used a custom-designed system allowing computed tomography (CT)-based preoperative planning, intraoperative navigation, and postoperative evaluation. Five orthopedic surgeons defined common preoperative plans on 3-dimensional CT reconstructed cadaveric shoulders. Each surgeon performed 3 computer-assisted and 3 conventional simulated procedures. The 3-dimensional CT reconstructed postoperative units were digitally matched to the preoperative model for evaluation of entry points, end points, and angulations of screws and baseplate. Values were used to find accuracy and precision of the 2 groups with respect to the defined placement. Statistical analysis was performed by t tests (α = .05). Comparison of the groups revealed no difference in accuracy or precision of screws or baseplate entry points (P > .05). Accuracy and precision were improved with use of navigation for end points and angulations of 3 screws (P < .05). Accuracy of the inferior screw showed a trend of improvement with navigation (P > .05). Navigated baseplate end point precision was improved (P < .05), with a trend toward improved accuracy (P > .05). We conclude that CT-based preoperative planning and intraoperative navigation allow improved accuracy and precision for screw placement and precision for baseplate positioning with respect to a predefined placement compared with conventional techniques in RSA. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Can patients manage toileting after reverse total shoulder arthroplasty? A systematic review.
Rojas, Jorge; Joseph, Jacob; Liu, Bingli; Srikumaran, Uma; McFarland, Edward G
2018-03-23
A major concern for patients undergoing reverse total shoulder arthroplasty (RTSA) is managing toileting after surgery. The goals of this systematic review of RTSA studies were to determine the following: (1) the percentage of patients who can manage toileting, (2) their degree of difficulty with toileting, and (3) the percentage of patients who can manage toileting after bilateral versus unilateral RTSA. Medline, EMBASE, Google Scholar, and the Cochrane Central Register of Controlled Trials were searched for studies reporting the ability to manage toileting after RTSA. Six studies with at least 12 months of follow-up were included, yielding 183 patients (105 unilateral RTSA, 78 bilateral RTSA). We pooled patient data and calculated the weighted mean proportion of patients able to manage toileting, those who reported difficulty, and those able to manage toileting after unilateral versus bilateral RTSA. Statistical significance was set at P < 0.05. Most patients (92%; 95% confidence interval, 87-95%) were able to manage toileting after RTSA. Some degree of difficulty with toileting was reported for 20% of all shoulders. Almost all patients with bilateral RTSA were able to manage toileting with at least one arm (weighted mean proportion 97%; 95% confidence interval, 88-99%). There was no significant difference in the proportion of patients able to manage toileting after unilateral versus bilateral RTSA (P = 0.08). Only 3% of all papers published on the clinical results of RTSA by June 2017 reported upon toileting after the procedure. With the available evidence, most patients were able to manage toileting after RTSA, although one-fifth reported some degree of difficulty. Ability to manage toileting was similar after unilateral versus bilateral RTSA. In the future, this variable should be a standard question after shoulder arthroplasty. IV.
Prosthetic replacement for proximal humeral fractures.
Kontakis, George; Tosounidis, Theodoros; Galanakis, Ioannis; Megas, Panagiotis
2008-12-01
The ideal management of complex proximal humeral fractures continues to be debatable. Evolution of proximal humeral fracture management, during the past decade, led to the implementation of many innovations in surgical treatment. Even though the pendulum of treatment seems to swing towards new trends such as locked plating, hemiarthroplasty remains a valid and reliable option that serves the patient's needs well. Hemiarthroplasty is indicated for complex proximal humeral fractures in elderly patients with poor bone stock and when internal fixation is difficult or unreliable. Hemiarthroplasty provides a better result when it is performed early post-injury. Stem height, retroversion and tuberosity positioning are technical aspects of utmost importance. Additionally reverse total shoulder arthroplasty is an alternative new modality that can be used as a primary solution in selected patients with proximal humeral fracture treatment. Failed hemiarthroplasty and fracture sequelae can be successfully managed with reverse total shoulder arthroplasty. Individual decision-making and tailored treatment that takes into consideration the personality of the fracture and the patient's characteristics should be used.
Kelly, James D; Humphrey, C Scott; Norris, Tom R
2008-01-01
The Aequalis Reversed Shoulder Prosthesis (Tornier, Inc., Edina, MN) is a successful treatment option for older, low-demand patients with rotator cuff arthropathy. Scapular notching is the most common radiographic complication and is associated with poorer intermediate-term clinical outcomes. Aligning the lower border of the glenosphere baseplate with the inferior glenoid rim has been recommended to reduce this complication, but guidelines for achieving this positioning are currently lacking. The purpose of this study is to develop a rule of thumb that will facilitate proper glenosphere component positioning intraoperatively. Utilizing a computed tomography-templating protocol, we found that the ideal location of the drill hole for the baseplate post was 11.5 +/- 1.0 mm above the inferior glenoid rim. On the basis of measurements from 10 implanted cadaveric specimens, we concluded that drilling the baseplate posthole 12 mm above the inferior glenoid rim-the 12-mm rule-will result in excellent glenosphere position in most cases.
Reverse shoulder arthroplasty combined with latissimus dorsi transfer using the bone-chip technique.
Ortmaier, Reinhold; Resch, Herbert; Hitzl, Wolfgang; Mayer, Michael; Blocher, Martina; Vasvary, Imre; Mattiassich, Georg; Stundner, Ottokar; Tauber, Mark
2014-03-01
Reverse shoulder arthroplasty (RSA) can restore active elevation in rotator-cuff-deficient shoulders. However, RSA cannot restore active external rotation. The combination of latissimus dorsi transfer with RSA has been reported to restore both active elevation and external rotation. We hypothesised that in the combined procedure, harvesting the latissimus dorsi with a small piece of bone, leads to good tendon integrity, low rupture rates and good clinical outcome. Between 2004 and 2010, 13 patients (13 shoulders) were treated with RSA in combination with latissimus dorsi transfer in a modified manner. The mean follow-up was 65.4 months, and the mean age at index surgery was 71.1 years. All patients had external rotation lag sign and positive hornblower's sign, as well as radiological signs of cuff-tear arthropathy (Hamada 3, 4 or 5) and fatty infiltration grade 3 according to Goutallier et al. on magnetic resonance imaging (MRI). The outcome measures included the Constant Murley Score, University of California-Los Angeles (UCLA) shoulder score, Simple Shoulder Test (SST), visual analogue scale (VAS) and the Activities of Daily Living Requiring External Rotation (ADLER) score. Tendon integrity was evaluated with dynamic ultrasound. All patients were asked at final follow-up to rate their satisfaction as excellent, good, satisfied or dissatisfied. The overall mean Constant-Murley Shoulder Outcome Score (CMS) improved from 20.4 to 64.3 points (p < 0.001). Mean VAS pain score decreased from 6.8 to 1.1 (p < 0.001)., mean UCLA score improved from 7.9 to 26.4 (p < 0.001), mean SST score improved from 2.3 to 7.9 (p < 0.001) and mean postoperative ADLER score was 26 points. The average degree of abduction improved from 45° to 129° (p < 0.001), the average degree of anterior flexion improved from 55° to 138° (p < 0.001) and the average degree of external rotation improved from -16° to 21° (p < 0.001). Eight patients rated their results as very satisfied, three as satisfied and two as dissatisfied. This modified technique, which avoids cutting the pectoralis major tendon and involves harvesting the tendon together with a small piece of bone, leads to good or even better functional results compared with the results reported in the literature, and also has high patient satisfaction and low failure rates.
[Knee and shoulder arthroscopy. Positioning and thermal injuries].
Meyer, S; Lobenhoffer, P
2008-11-01
Intraoperative positioning injuries during shoulder- and knee arthroscopy are rare complications and affect mainly nerves and soft tissue. Although the majority of these complications are reversible, in some cases serious negative consequences for the patient persist. This article describes the frequency of several positioning injuries including their prevention and the appropriate treatment. The legal responsibilities are illustrated as well as the importance of an intense preoperative investigation of preexisting diseases and possible risk factors. Furthermore, a review of possible thermal injuries of the patient during arthroscopy caused by e.g. electrosurgical instruments or the cold light source, is given as well as prevention strategies.
Serum C-reactive protein in patients undergoing elective shoulder arthroplasty. Prospective study.
Torrens, Carlos; Santana, Fernando; Marí, Raquel; Puig, Lluis; Alier, Albert
2017-09-01
The objective of the study was to determine the normalization curve of the serum C-reactive protein (CRP) in elective shoulder arthroplasty. A prospective study including 58 consecutive patients who had undergone elective shoulder arthroplasty. Forty-one patients had received a Reverse Shoulder Arthroplasty, 13 a Total Shoulder Arthroplasty and 4 a Hemiarthroplasty. Based on a pilot study, blood samples to determine CRP values were obtained at baseline (1 h before surgery), on the 1st, 2nd, 6th, 8th and 14th postoperative days. All the patients included presented no postoperative complications during inpatient stay or any re-admission during the three months after surgery. Mean CRP values showed a rapid increase on the 1st postoperative day (7-fold higher than the baseline in cuff tear arthropathy, 11-fold higher in primary osteoarthritis, 1-fold higher in acute fracture) and reached a peak on the 2nd postoperative day (14-fold higher than the baseline in cuff tear arthropathy, 24-fold higher in primary osteoarthritis and 2-fold higher in acute fracture). After the 2nd postoperative day CRP values began to slowly decrease reaching the normal range in the 14th postoperative day. Serum CRP levels after elective shoulder arthroplasty rapidly increase to reach a maximum peak after the 2nd surgery day and then slowly decrease to return to normality on the 14th day. Knowing the normalization curve of CRP can be a helpful tool to help in the diagnosis of acute infections in elective shoulder arthroplasty. Copyright © 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Chen, Hongwei; Wang, Ziyang; Shang, Yongjun
2018-06-01
To compare clinical outcomes of unipolar and bipolar radial head prosthesis in the treatment of patients with radial head fracture. Medline, Cochrane, EMBASE, Google Scholar databases were searched until April 18, 2016 using the following search terms: radial head fracture, elbow fracture, radial head arthroplasty, implants, prosthesis, unipolar, bipolar, cemented, and press-fit. Randomized controlled trials, retrospective, and cohort studies were included. The Mayo elbow performance score (MEPS), disabilities of the arm, shoulder, and hand (DASH) score, radiologic assessment, ROM, and grip strength following elbow replacement were similar between prosthetic devices. The pooled mean excellent/good ranking of MEPS was 0.78 for unipolar and 0.73 for bipolar radial head arthroplasty, and the pooled mean MEPS was 86.9 and 79.9, respectively. DASH scores for unipolar and bipolar prosthesis were 19.0 and 16.3, respectively. Range of motion outcomes were similar between groups, with both groups have comparable risk of flexion arc, flexion, extension deficit, rotation arc, pronation, and supination (p values <0.001 for both unipolar and bipolar prosthesis). However, bipolar radial head prosthesis was associated with an increased chance of heterotopic ossification and lucency (p values ≤0.049) while unipolar prosthesis was not (p values ≥0.088). Both groups had risk for development of capitellar osteopenia or erosion/wear (p values ≤0.039). Unipolar and bipolar radial head prostheses were similar with respect to clinical outcomes. Additional comparative studies are necessary to further compare different radial head prostheses used to treat radial head fracture.
Mechanisms of traumatic shoulder injury in elite rugby players.
Crichton, James; Jones, Doug R; Funk, Lennard
2012-06-01
Shoulder injuries in rugby players are common, but the mechanisms of injury are less well understood. This study aims to elucidate common mechanisms of injury and identify the patterns of injury they produce. Twenty-four elite rugby players, referred to the senior author for diagnosis and management of shoulder injuries, were selected. Videos of the injuries were independently reviewed by rugby-medical experts to describe the mechanisms of injury. The mechanisms reported were collated and analysed to determine the level of agreement between reviewers and conclude an overall description of injury mechanisms. The authors identified three mechanisms of shoulder injury from the video analysis. These are the 'Try-Scorer', characterised by hyperflexion of the outstretched arm such as when scoring a try; the 'Tackler', extension of the abducted arm behind the player while tackling; and the 'Direct Impact', a direct blow to the arm or shoulder when held by the side in neutral or slight adduction. The Try Scorer and Tackler mechanisms both involve a levering force on the glenohumeral joint (GHJ). These mechanisms predominantly cause GHJ dislocation, with Bankart, reverse Bankart and superior labrum anterior-posterior tears. The Try-Scorer Mechanism also caused the majority (83%) of rotator cuff tears. The Direct Hit mechanism resulted in GHJ dislocation and labral injury in 37.5% of players and was most likely to cause acromioclavicular joint dislocation and scapula fractures, injuries that were not seen with the other mechanisms. Greater understanding of the mechanisms involved in rugby shoulder injury is useful in understanding the pathological injuries, guiding treatment and rehabilitation and aiding the development of injury-prevention methods.
Zilber, Sebastien; Camana, Eleonora; Lapner, Peter; Haritinian, Emil; Nove Josserand, Laurent
2018-03-26
Glenoid loosening is a common cause of reverse total shoulder arthroplasty (RTSA) failure, and grafting of the glenoid is often required for revision due to bone loss due to the central peg in most glenoid baseplates. Helical blades have been used in the hip to optimize bone fixation in proximal femoral fracture. This study presents the initial results of specifically designed helical blade in the shoulder to optimize glenoid bone fixation and preservation as part of RTSA. Thirty-five patients underwent RTSA with glenoid helical blade fixation. An uncemented glenoid baseplate was used with a central helical blade partially coated with hydroxyapatite and two or three screws. Outcome analysis was performed pre-operatively and at two years. All patients were satisfied with the results and significant improvement was observed in functional outcome scores between baseline and final follow-up. There was a single intra-operative undisplaced glenoid fracture which did not compromise the baseplate fixation. There was no radiographic evidence of loosening or radiolucencies around the helical blade. The helical blade provides a satisfactory primary fixation. Because of its length (21 mm), care should be taken in cases of pre-existing bone loss or sclerotic bone to avoid glenoid fracture or anterior cortical perforation. Helical blade has the potential to facilitate glenoid implant revision by preserving the glenoid bone stock.
Neuroprostheses to treat neurogenic bladder dysfunction: current status and future perspectives.
Rijkhoff, Nico J M
2004-02-01
Neural prostheses are a technology that uses electrical activation of the nervous system to restore function to individuals with neurological or sensory impairment. This article provides an introduction to neural prostheses and lists the most successful neural prostheses (in terms of implanted devices). The article then focuses on neurogenic bladder dysfunction and describes two clinically available implantable neural prostheses for treatment of neurogenic bladder dysfunction. Special attention is given to the usage of these neural prostheses in children. Finally, three new developments that may lead to a new generation of implantable neural prostheses for bladder control are described. They may improve the neural prostheses currently available and expand further the population of patients who can benefit from a neural prosthesis.
... the same day you have the procedure. Some women may need to stay in the hospital overnight. You will need a ride home. It may take a week or more to recover from this surgery. You will have some tenderness and pain. Your provider ... you can take. Many women will have shoulder pain for a few days. ...
Blackwood, Craig; Dixon, Jen; Reilly, Peter; Emery, Roger J
2017-01-01
This paper seeks to outline recent legal developments and requirements pertinent to obtaining informed consent. We argue that this is of particular relevance to patients considering a reverse total shoulder arthroplasty, due to the high complication rate associated with this procedure. By examining the cognitive processes involved in decision-making, and other clinician-related factors such as delivery of information, gender bias and conflict of interest, we explore some of the barriers that can undermine the processes of shared decision-making and obtaining genuine informed consent. We argue that these issues highlight the importance for surgeons in understanding the cognitive processes and other influential factors involved in patients' comprehension and decision-making. We recommend, based on strong evidence, that decision aids could prove useful in overcoming such challenges and could provide one way of mitigating the ethical, professional and legal consequences of failing to obtain proper informed consent. They are not widely used in orthopaedics at present, although it would be in the interests of both the surgeon and patient for such measures to be explored.
Blackwood, Craig; Reilly, Peter; Emery, Roger J
2016-01-01
This paper seeks to outline recent legal developments and requirements pertinent to obtaining informed consent. We argue that this is of particular relevance to patients considering a reverse total shoulder arthroplasty, due to the high complication rate associated with this procedure. By examining the cognitive processes involved in decision-making, and other clinician-related factors such as delivery of information, gender bias and conflict of interest, we explore some of the barriers that can undermine the processes of shared decision-making and obtaining genuine informed consent. We argue that these issues highlight the importance for surgeons in understanding the cognitive processes and other influential factors involved in patients’ comprehension and decision-making. We recommend, based on strong evidence, that decision aids could prove useful in overcoming such challenges and could provide one way of mitigating the ethical, professional and legal consequences of failing to obtain proper informed consent. They are not widely used in orthopaedics at present, although it would be in the interests of both the surgeon and patient for such measures to be explored. PMID:28572846
Longitudinal research on the oral environment of elderly wearing fixed or removable prostheses.
Tanaka, Junko; Tanaka, Masahiro; Kawazoe, Takayoshi
2009-04-01
The purpose of this study was to investigate oral environmental risk factors involved in caries incidence in the elderly. We investigated the relationship between the oral environment factors of the elderly with both fixed prostheses and removable prostheses at baseline and at follow-up and examined time-course changes of each oral environmental factor by prosthesis type. The subject group consisted 11 elderly patients with fixed prostheses and 11 who wore removable prostheses. We examined oral environmental factors by saliva tests. Five oral environmental factors were examined: the stimulated salivary flow rate, buffering capacity, and the counts of mutans streptococci (SM), lactobacilli (LB), and Candida (CA). We compared these factors for subjects with fixed prostheses and those wearing removable prostheses at baseline and at follow-up. Furthermore, 3-year changes in the factors of each oral environment were compared and evaluated. Significant differences were observed between the two groups in the salivary microbial counts of SM and LB at baseline and at follow-up. The LB counts increased in the Denture group during the 3-year period and significant differences were noted. We found that fixed prostheses are less cariogenic, and removable prostheses cause an increase in the cariogenic bacterial count. Regarding time-course changes by the type of prosthesis, the LB count tended to increase in the subjects with removable prostheses. The risk of caries due to a fixed prosthesis may be lower than that of removable prostheses.
Königshausen, M; Jettkant, B; Sverdlova, N; Ehlert, C; Gessmann, J; Schildhauer, T A; Seybold, D
2015-01-01
There is no biomechanical basis to determine the influence of different length of the central peg of the baseplate anchored within the native scapula in glenoid defect reconstruction in cases of degenerative or posttraumatic glenoid bone loss in reversed shoulder arthroplasty. The purpose of this study was to analyse the stability of different peg lengths used in glenoid bone loss in reversed shoulder arthroplasty. Different lengths of metaglene pegs with different depths of peg anchorage performed with or without metaglene screws in sawbone foam blocks were loaded in vertical and horizontal directions for differentiating load capacities. Simulated physiological loadings were then applied to the peg implants to determine the limits of loading in each depth of anchorage. The loading capacity of the implant was reduced as less of the peg was anchored. The vertically loaded implants showed a significantly higher stability, in contrast to those loaded horizontally at a corresponding peg length and depth of anchorage (p < 0.05). The tests revealed that the metaglene screws are more essential for primary stability than is the peg particularly in the vertically directed loadings (2/3 anchored: peg contributed to 28% of the stability, 1/3 anchorage: peg contributed to 12%). Under the second test conditions, the lowest depth of peg anchorage (1/3) resulted in 322 Newtons [N] in the long peg with a vertical loading direction, and in 130 N in the long peg with a horizontal loading direction (p < 0.05). The pegs should be anchored as deeply as possible into the native scapula bone stock. The metaglene screws play a major role in the initial stability, in contrast to the peg, and they become more important when the depth of the peg anchorage is reduced. If possible, four metaglene screws should be used in cases of uncontained bone loss to guarantee the highest stability.
a Review of Retinal Prosthesis Approaches
NASA Astrophysics Data System (ADS)
Kien, Tran Trung; Maul, Tomas; Bargiela, Andrzej
Age-related macular degeneration and retinitis pigmentosa are two of the most common diseases that cause degeneration in the outer retina, which can lead to several visual impairments up to blindness. Vision restoration is an important goal for which several different research approaches are currently being pursued. We are concerned with restoration via retinal prosthetic devices. Prostheses can be implemented intraocularly and extraocularly, which leads to different categories of devices. Cortical Prostheses and Optic Nerve Prostheses are examples of extraocular solutions while Epiretinal Prostheses and Subretinal Prostheses are examples of intraocular solutions. Some of the prostheses that are successfully implanted and tested in animals as well as humans can restore basic visual functions but still have limitations. This paper will give an overview of the current state of art of Retinal Prostheses and compare the advantages and limitations of each type. The purpose of this review is thus to summarize the current technologies and approaches used in developing Retinal Prostheses and therefore to lay a foundation for future designs and research directions.
Within-subject comparisons of implant-supported mandibular prostheses: psychometric evaluation.
de Grandmont, P; Feine, J S; Taché, R; Boudrias, P; Donohue, W B; Tanguay, R; Lund, J P
1994-05-01
In a within-subject cross-over clinical trial, psychometric and functional measurements were taken while 15 completely edentulous subjects wore mandibular fixed prostheses and long-bar removable implant-supported prostheses. In this paper, the results of a psychometric assessment are presented. Eight subjects first received the fixed bridge and seven the removable type. After having worn a prosthesis for a minimum of two months, subjects responded to psychometric scales that measured their perceptions of various factors associated with prostheses. They also chewed test foods while masticatory activity was recorded. The prostheses were then changed and the procedures repeated. At the end of the study, patients were asked to choose the prosthesis that they wished to keep. Patients assigned significantly higher scores, on visual analogue scales, to both types of implant-supported prostheses than to their original conventional prostheses for all factors tested, including general satisfaction. However, no statistically significant differences between the two implant-supported prostheses were detected except for the difficulty of chewing carrot, apple, and sausage. For these foods, the fixed prostheses were rated higher. Subjects' responses to category scales were consistent with their responses to the visual analogue scales. These results suggest that, although patients find the fixed bridge to be significantly better for chewing harder foods, there is no difference in their general satisfaction with the two types of prostheses.
Mechanisms of traumatic shoulder injury in elite rugby players
Crichton, James; Jones, Doug R; Funk, Lennard
2012-01-01
Background Shoulder injuries in rugby players are common, but the mechanisms of injury are less well understood. This study aims to elucidate common mechanisms of injury and identify the patterns of injury they produce. Materials and methods Twenty-four elite rugby players, referred to the senior author for diagnosis and management of shoulder injuries, were selected. Videos of the injuries were independently reviewed by rugby-medical experts to describe the mechanisms of injury. The mechanisms reported were collated and analysed to determine the level of agreement between reviewers and conclude an overall description of injury mechanisms. Results The authors identified three mechanisms of shoulder injury from the video analysis. These are the ‘Try-Scorer’, characterised by hyperflexion of the outstretched arm such as when scoring a try; the ‘Tackler’, extension of the abducted arm behind the player while tackling; and the ‘Direct Impact’, a direct blow to the arm or shoulder when held by the side in neutral or slight adduction. The Try Scorer and Tackler mechanisms both involve a levering force on the glenohumeral joint (GHJ). These mechanisms predominantly cause GHJ dislocation, with Bankart, reverse Bankart and superior labrum anterior–posterior tears. The Try-Scorer Mechanism also caused the majority (83%) of rotator cuff tears. The Direct Hit mechanism resulted in GHJ dislocation and labral injury in 37.5% of players and was most likely to cause acromioclavicular joint dislocation and scapula fractures, injuries that were not seen with the other mechanisms. Conclusion Greater understanding of the mechanisms involved in rugby shoulder injury is useful in understanding the pathological injuries, guiding treatment and rehabilitation and aiding the development of injury-prevention methods. PMID:22510645
NASA Astrophysics Data System (ADS)
Parikh, Hirak; Marzullo, Timothy C.; Kipke, Daryl R.
2009-04-01
Improving cortical prostheses requires the development of recording neural interfaces that are efficient in terms of providing maximal control information with minimal interface complexity. While the typical approaches have targeted neurons in the motor cortex with multiple penetrating shanks, an alternative approach is to determine an efficient distribution of electrode sites within the layers of the cortex with fewer penetrating shanks. The objective of this study was to compare unit activity in the upper and lower layers of the cortex with respect to movement and direction in order to inform the design of penetrating microelectrodes. Four rats were implanted bilaterally with multi-site single-shank silicon microelectrode arrays in the neck/shoulder region of the motor cortex. We simultaneously recorded unit activity across all layers of the motor cortex while the animal was engaged in a movement direction task. Localization of the electrode array within the different layers of the cortex was determined by histology. We denoted units from layers 2 and 3 and units as upper layer units, and units from layers 5 and 6 as lower layer units. Analysis of unit spiking activity demonstrated that both the upper and lower layers encode movement and direction information. Unit responses in either cortical layer of the cortex were not preferentially associated with contralateral or ipsilateral movement. Aggregate analysis (633 neurons) and best session analysis (75 neurons) indicated that units in the lower layers (layers 5, 6) are more likely to encode direction information when compared to units in the upper layers (layers 2, 3) (p< 0.05). These results suggest that electrode sites clustered in the lower layers provide access to more salient control information for cortical neuroprostheses.
2013-01-01
Background Rotation of the torso while reaching produces torques (e.g., Coriolis torque) that deviate the arm from its planned trajectory. To ensure an accurate reaching movement, the brain may take these perturbing torques into account during movement planning or, alternatively, it may correct hand trajectory during movement execution. Irrespective of the process selected, it is expected that an underestimation of trunk rotation would likely induce inaccurate shoulder and elbow torques, resulting in hand deviation. Nonetheless, it is still undetermined to what extent a small error in the perception of trunk rotations, translating into an inappropriate selection of motor commands, would affect reaching accuracy. Methods To investigate, we adapted a biomechanical model (J Neurophysiol 89: 276-289, 2003) to predict the consequences of underestimating trunk rotations on right hand reaching movements performed during either clockwise or counter clockwise torso rotations. Results The results revealed that regardless of the degree to which the torso rotation was underestimated, the amplitude of hand deviation was much larger for counter clockwise rotations than for clockwise rotations. This was attributed to the fact that the Coriolis and centripetal joint torques were acting in the same direction during counter clockwise rotation yet in opposite directions during clockwise rotations, effectively cancelling each other out. Conclusions These findings suggest that in order to anticipate and compensate for the interaction torques generated during torso rotation while reaching, the brain must have an accurate prediction of torso rotation kinematics. The present study proposes that when designing upper limb prostheses controllers, adding a sensor to monitor trunk kinematics may improve prostheses control and performance. PMID:23758968
Grimberg, Jean; Diop, Amadou; Kalra, Kunal; Charousset, Christophe; Duranthon, Louis-Denis; Maurel, Nathalie
2010-03-01
We assessed bone-tendon contact surface and pressure with a continuous and reversible measurement system comparing 3 different double- and single-row techniques of cuff repair with simulation of different joint positions. We reproduced a medium supraspinatus tear in 24 human cadaveric shoulders. For the 12 right shoulders, single-row suture (SRS) and then double-row bridge suture (DRBS) were used. For the 12 left shoulders, DRBS and then double-row cross suture (DRCS) were used. Measurements were performed before, during, and after knot tying and then with different joint positions. There was a significant increase in contact surface with the DRBS technique compared with the SRS technique and with the DRCS technique compared with the SRS or DRBS technique. There was a significant increase in contact pressure with the DRBS technique and DRCS technique compared with the SRS technique but no difference between the DRBS technique and DRCS technique. The DRCS technique seems to be superior to the DRBS and SRS techniques in terms of bone-tendon contact surface and pressure. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Fottner, Andreas; Schmid, Markus; Birkenmaier, Christof; Mazoochian, Farhad; Plitz, Wolfgang; Volkmar, Jansson
2009-06-01
Stemless and short-stemmed hip prostheses have been developed to preserve femoral bone stock. While all these prostheses claim a more or less physiological load transfer, clinical long-term results are only available for the stemless thrust plate prosthesis. In this study, the in vitro primary stability of the thrust plate prosthesis was compared to two types of short-stemmed prostheses. In addition to the well-established Mayo prosthesis, the modular Metha prosthesis was tested using cone adapters with 130 degrees and 140 degrees neck-shaft-angles. The prostheses were implanted in composite femurs and loaded dynamically (300-1700 N). Three-dimensional micromotions at the bone-prosthesis interface were measured. In addition, the three-dimensional deformations at the surface of the composite femur were measured to gain data on the strain distribution. For all tested prostheses, the micromotions did not exceed 150 microm, the critical value for osteointegration. The thrust plate prosthesis revealed similar motions as the short-stemmed prostheses. The short-stemmed prosthesis with the 130 degrees cone tended to have the highest micromotions of all tested short-stemmed prostheses. The thrust plate prosthesis revealed the lowest alteration of bone surface deformation after implantation. The comparably low micromotions of the thrust plate prosthesis and the short-stemmed prostheses should be conducive to osseous integration. The higher alteration of load transmission after implantation reveals a higher risk of stress shielding for the short-stemmed prostheses.
Duan, Yonghong; Zhu, Shu; Guo, Fei; Zhu, Jinyu; Li, Mao; Ma, Jie
2012-01-01
Introduction With the increase in joint revision surgery after arthroplasty, defects of hydroxyapatite (HA)-coated prostheses have been observed increasingly often. These defects adversely affect the prosthetic stability in vivo. This study has analyzed the potential effect of the adhesive strength of HA coating on the stability of HA-coated prostheses in vivo after its implantation. Material and methods Sixty experimental rabbits were divided into HA- and Ti-coated groups. HA-coated prostheses were implanted into the bilateral epicondyle of rabbits femurs. Ti-coated prostheses were implanted as control. At different time points(4, 9, and 15 weeks) after implantation, bone tissue samples were fetched out respectively for histomorphometric analysis. Push-out testing was used to detect the ultimate shear strength at the bone-prosthesis interface. Scanning electron microscope (SEM) observation and energy-dispersive X-ray spectroscopy (EDX) analysis were used to observe the changes in surface composition of the prostheses after the ultimate shear strength testing. The coating adhesive strength of two kinds of coatings were also examined by scratch testing. Results Hydroxyapatite coating has an obvious advantage in facilitating osteogenesis and its plays a critical role in the stability of prostheses. However, the ultimate shear strength of HA-coated prostheses is much lower than that of Ti-coated implants (p < 0.01). Further study has demonstrated that the stability of HA-coated prostheses in vivo is affected by the relatively low adhesive strength between coating and substrate. Conclusions Obvious advantage in facilitating osteogenesis around HA-coated prostheses is not the only factor that determines the stability of prostheses in vivo. PMID:22661990
Targeted Muscle Reinnervation for Real-Time Myoelectric Control of Multifunction Artificial Arms
Kuiken, Todd A.; Li, Guanglin; Lock, Blair A.; Lipschutz, Robert D.; Miller, Laura A.; Stubblefield, Kathy A.; Englehart, Kevin
2011-01-01
Context Improving the function of prosthetic arms remains a challenge, as access to the neural control information for the arm is lost during amputation. We have developed a surgical technique called targeted muscle reinnervation (TMR) which transfers residual arm nerves to alternative muscle sites. After reinnervation, these target muscles produce an electromyogram (EMG) on the surface of the skin that can be measured and used to control prosthetic arms. Objective Assess the performance of TMR upper-limb amputee patients using a pattern-recognition algorithm to decode EMG signals and control prosthetic arm motions. Design Surface EMG signals were recorded on participants and decoded using a pattern-recognition algorithm. The decoding program controlled the movement of a virtual prosthetic arm. Participants were instructed to perform various arm movements, and their abilities to control the virtual prosthetic arm were measured. In addition, TMR patients used the same control system to operate advanced arm prosthesis prototypes. Setting This study was conducted between January 2007 and January 2008 at the Rehabilitation Institute of Chicago. Participants This study included five patients with shoulder disarticulation or transhumeral amputations who received TMR surgery between February 2002 and October 2006. It also included five non-amputee (control) participants. Main Outcome Measure Performance metrics measured during virtual arm movements included motion-selection time, motion-completion time, and motion-completion (or `success') rate. Three of the TMR patients were also able to test advanced arm prostheses. Results TMR patients were able to repeatedly perform 10 different elbow, wrist and hand motions with the virtual prosthetic arm. For TMR patients, the average (standard deviation (SD)) motion-selection and motion-completion times for elbow and wrist movements were 0.22 s (0.06) and 1.29 s (0.15), respectively. These times were 0.06 s and 0.21 s longer than the average times of control participants. For TMR patients, the average (SD) motion-selection and motion-completion times for hand-grasp patterns were 0.38 s (0.12) and 1.54 s (0.27), respectively. TMR patients successfully completed an average (SD) of 96.3% (3.8) of elbow and wrist movements and 86.9% (13.9) of hand movements within 5 s, compared to 100% (0) and 96.7% (4.7) completed by controls. Three of the patients were able to demonstrate the use of this control system in advanced prostheses including motorized shoulders, elbows, wrists and hands. Conclusion These results suggest that reinnervated muscles can produce sufficient EMG information to control advanced artificial arms. PMID:19211469
Savin, David D; Zamfirova, Ina; Iannotti, Joseph; Goldberg, Benjamin A; Youderian, Ari R
2016-09-01
The role of reverse total shoulder arthroplasty (RTSA) for three and four-part proximal humerus fractures is evolving. However, there does not appear to be a clear consensus amongst surgeons. The purpose of this study is to further define the standard of care, assessing surgeon preference and treatment considerations for management of such fractures. Orthopaedic surgeons were surveyed on their training, practice setting, and experience regarding management of four-part proximal humerus fractures. The survey also presented five representative cases to assess treatment preferences. Two hundred five surgeons responded to the survey with fellowship training in shoulder and elbow surgery (114), orthopaedic trauma (35) or sports medicine/other training (56). There was no difference between respondents with years in practice and confidence with performing RTSA, however, surgeons in the academic setting were more confident in performing the surgery. Surgeons preferred RTSA for management of four-part fractures in patients over age 65. However, they also trended to favour hemiarthroplasty with higher co-morbidities. Physicians with more than 11 years of experience were more likely to choose hemiarthroplasty for older and high comorbidity patients. RTSA was not the preferred treatment method for younger, active patients. Patient age and fracture pattern had a greater influence on the surgeon's decision. There is a consensus in our study population that RTSA is the preferred treatment for four-part proximal humerus fractures for elderly patients with patient age and fracture pattern being the most important factors in making management decisions. Level III - Case controlled study.
[Time course of microbial colonization of different voice prostheses].
Schuldt, T; Dommerich, S; Pau, H-W; Kramp, B
2010-10-01
For the vocal rehabilitation of laryngectomized patients, voice prostheses are actually one of the best known methods. Caused by the surface colonisation with bacteria and fungi the life time of the prostheses is limited to 3-4 months. In a time period of 127 months we analysed the surface colonisation of 118 voice prostheses. The mean life time of the prostheses was 156 days. In reference to the prosthesis model we also recorded different times of usage (ESKA-Herrmann 141, Provox 2 184 and Provox 1 204 days (p>0.05)). In the microbiological examination the dominating bacteria were S. aureus, Klebsiella sp. and Proteus sp. It was possible to cultivate all these bacteria on every type of prosthesis used in the study. In addition C. albicans, C. glabrata, C. krusei and C. tropicalis were the main fungi on the silicone surface. Thereby a more frequent colonisation with C. krusei on ESKA-Herrmann prostheses was measured, caused by the bigger contact area with saliva on this model (p=0.034). Because of the similar position and way of function, all types of voice prostheses are colonized by almost the same species of bacteria and fungi. But in dependency of the type an affinity of individual species to special prostheses exist. The knowledge of these individual affinities is necessary for the further development of voice prostheses. Furthermore the diversity of bacteria and fungi species showed a level of saturation on the surface. This is caused by the limited space on the silicone prostheses. © Georg Thieme Verlag KG Stuttgart · New York.
Mechanical characterization and comparison of energy storage and return prostheses.
Rigney, Stacey M; Simmons, Anne; Kark, Lauren
2017-03-01
The suitability of finite element analysis (FEA) for standardizing the mechanical characterization of energy storage and return (ESAR) prostheses was investigated. A methodology consisting of both experimental and numerical analysis was proposed and trialed for the Vari-flex ® Modular TM , Flex-foot Cheetah and Cheetah Xtreme by Össur ® and a 1E90 Sprinter by Ottobock ® . Gait analysis was conducted to determine suitable orientation angles for non-destructive testing (NDT) of the ESAR prostheses followed by a quasi-static inverse FEA procedure within COMSOL Multiphysics ® , where the NDT conditions were replicated to determine the homogenized material properties of the prostheses. The prostheses' loading response under bodyweight for an 80kg person was then simulated, using both Eigenfrequency and time-dependent analysis. The apparent stiffness under bodyweight was determined to be 94.7, 48.6, 57.4 and 65.0Nmm -1 for the Vari-flex ® Modular TM , Flex-foot Cheetah, Cheetah Xtreme and 1E90 Sprinter, respectively. Both the energy stored and returned by the prostheses varied negatively with stiffness, yet the overall efficiency of the prostheses were similar, at 52.7, 52.0, 51.7 and 52.4% for the abovementioned prostheses. The proposed methodology allows the standardized assessment and comparison of ESAR prostheses without the confounding influences of subject-specific gait characteristics. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
ZHANG, XIN; WEI, LI-CHENG; WU, BIN; YU, LI-YING; WANG, XIAO-PING; LIU, YUE
2016-01-01
The present study aimed to provide guidance for the selection of prosthodontic materials and the management of patients with a suspected metal allergy. This included a comparison of the sensitivity of patients to alloys used in prescribed metal-containing prostheses, and correlation analysis between metal allergy and accompanying clinical symptoms of sensitized patients using a patch test. The results from the patch test and metal component analyses were processed to reach a final diagnosis. In the present study, four dental alloys were assessed. Subsequent to polishing the surface of a metal restoration, the components were analyzed using an X-ray fluorescence microscopy and spectrometry. Immunohistochemical analysis, reverse transcription-polymerase chain reaction and western blotting were used to detect the expression levels of human leukocyte antigen (HLA)-DR in gingival tissues affected by alloy restoration, and in normal gingival tissue samples. Positive allergens identified in the patch test were consistent with the components of the metal prostheses. The prevalence of nickel (Ni) allergy was highest (22.8%), and women were significantly more allergic to palladium and Ni than men (P<0.05). The protein and gene expression levels of HLA-DR in the Ni-chromium (Cr) prosthesis group were significantly higher, compared with those in the other groups (P<0.01); followed by cobalt-Cr alloy, gold alloy and titanium alloy. In conclusion, dentists require an understanding of the corrosion and allergy rates of prescribed alloys, in order to reduce the risk of allergic reactions. Patch testing for hypersensitive patients is recommended and caution is required when planning to use different alloys in the mouth. PMID:26573458
[Long-term observation of 920 porcelain fused to metal prostheses].
Jiang, Yong-Lin; Sun, Jian; Weng, Wei-Min; Zhang, Fu-Qiang
2006-10-01
To evaluate the long-term clinical results of porcelain fused to metal prostheses. Since January 1995, 920 porcelain fused to metal prostheses were fabricated. The long-term outcome were evaluated according to the condition of the prosthese, abutment and the periodontal tissue in the respects of successful rate and causes of failure. 74 patients were found to be during the follow up period, including 36 anterior crowns (46 units), 18 posterior crowns (22 units), 12 percentage of anterior bridges and 8 posterior bridges. The overall failure rate was 8.04%, 4.84% for crown, 8.77% for bridge. The failed prostheses was 5.39%. Porcelain fused to metal prostheses is an ideal method for restoration. The standard process both for the clinician and the technician must be obeyed to improve the success rate.
Combined tooth-implant-supported telescopic prostheses in a midterm follow-up of > 2 years.
Joda, Tim
2013-01-01
The aim of this trial was to evaluate telescopic-retained prostheses on teeth and implants. Ten patients with a mean of 2.8 teeth received strategic implants to achieve triangular/quadrangular support. Survival and complication rates were estimated for telescopic abutments and prostheses. After a mean observation period of > 2 years, no abutment was lost and all prostheses were in function. Complication rates were low, and maintenance services were limited to minor interventions. Combined tooth-implant-retained telescopic prostheses improve prosthetic support and offer successful function over a midterm period in patients with a severely reduced dentition.
Gu, X Y; Chen, X B; Jiao, T; Zhang, F Q; Jiang, X Q
2017-06-09
Objective: To explore a digital negative molds technique based on three-dimensional (3D) printing to assist in the manufacture of maxillofacial prostheses, and to improve the deficiency of the current clinical treatment. Methods: Seventeen patients with maxillofacial defects (including nasal defects, orbital defects, cheek defects, auricle defect) were scanned by means of facial optical scanning and computer tomography (CT). The 3D models were then reconstructed and global registration was made to merge the reconstructed models into a new digital model for 3D design. The 3D design of the prostheses was implemented in software. The mechanical connection structure was designed by forward engineering technology for 3 patients with intra-oral defects in maxilla who needed to make removable partial dentures, so that the silicone prostheses and removable partial denture could be combined. The removable partial dentures were made by conventional method and connected with the prostheses. According to the 3D data of the prostheses, the digital negative molds were designed, and the 3D printing technology was used to finish the processing of the resin molds. Silicone for prostheses were filled and cured in the resin molds to fabricate the clinical restorations for the patients. The margin adaptation and retention of the prostheses was detected. Results: Twenty patients with varying degrees of maxillofacial defects were rehabilitated using the courses developed in the study. All patients reported no pain or discomfort during the treatment; and they were satisfied with the final prostheses of the shape, color, retention, stability, etc. Eighteen of the prostheses showed good marginal adaptation, and sixteen of the prostheses showed good retention effect. Conclusions: The digital negative molds technique used in this study could greatly reduce the intensity of manual operation and provided a good therapeutic effect for patients with maxillofacial defects.
Leijendekkers, Ruud A; van Hinte, Gerben; Frölke, Jan Paul; van de Meent, Hendrik; Nijhuis-van der Sanden, Maria W G; Staal, J Bart
2017-06-01
This study aimed to provide an overview of a) the used measurement instruments in studies evaluating effects on quality of life (QoL), function, activity and participation level in patients with a lower extremity amputation using bone-anchored prostheses compared to socket prostheses and b) the effects themselves. A systematic literature search was conducted in MEDLINE, Cochrane, EMBASE, CINAHL and Web of Science. Included studies compared QoL, function, activity and/or participation level in patients with bone-anchored or socket prostheses. A best-evidence synthesis was performed. Out of 226 studies, five cohort and two cross-sectional studies were eligible for inclusion, all had methodological shortcomings. These studies used 10 different measurement instruments and two separate questions to assess outcome. Bone-anchored prostheses were associated with better condition-specific QoL and better outcomes on several of the physical QoL subscales, outcomes on the physical bodily pain subscale were inconclusive. Outcomes on function and activity level increased, no change was found at participation level. The level of evidence was limited. There is a need for a standard set of instruments. There was limited evidence that bone-anchored prostheses resulted in higher QoL, function and activity levels than socket prostheses, in patients with socket-related problems. Implications for Rehabilitation Use of bone-anchored prostheses in combination with intensive outpatient rehabilitation may improve QoL, function and activity level compared with socket prosthesis use in patients with a transfemoral amputation and socket-related problems. All clinicians and researchers involved with bone-anchored prostheses should use and publish data on QoL, function, activity and participation level. There needs to be an agreement on a standard set of instruments so that interventions for patients with a lower extremity amputation are assessed consistently.
Lipsker, A; Saljoghi, R; Lecuelle, D; Caillet, K; Alezra, E; Le Roux, F; Demailly, M; Saint, F
2016-09-01
Patients who are not responding to injectable and/or vacuum oral pharmacological treatments can receive a penile prosthesis. Three types of penile prostheses are used in France: rigid, semi-rigid and inflatable prostheses 3-piece or 2-piece. We have assessed the National surgical insertion practices between 2006 and 2013 (number of prostheses insertions, types, procedure locations, number of surgeons and distribution [public or private sectors]). Data analysis from the French Technical Agency of Information on Hospitals (ATIH) (2006-2013) using the common classification of medical acts (CCAM) and after code extractions related to this surgery (JHLA002, JHLA003, JHLA004). Between 2006 and 2013, the number of penile implants in France doubled (307 to 633), inflatable penile prostheses with an extracavernous component remained the most frequently used (87 %) (228 to 552) (+142 %). The use of semi-rigid prostheses declined by 26.7 %. The distribution between the private and public sector was close to 1 in 2013. More than half of French penile prostheses were implanted in three regions (Île-de-France, Languedoc-Roussillon, Rhône-Alpes). Nearly 62 % of surgeons implanted only one or two three-compartment prostheses in 2013. The number of penile prostheses in France doubled between 2006 and 2013. Three regions were particularly active as far as this surgery is concerned (Île-de-France, Languedoc-Roussillon, Rhône-Alpes). They were boosted by 5 surgeons with more than 20 prostheses surgeries a year. 4. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Dual jaw treatment of edentulism using implant-supported monolithic zirconia fixed prostheses.
Altarawneh, Sandra; Limmer, Bryan; Reside, Glenn J; Cooper, Lyndon
2015-01-01
This case report describes restoration of the edentulous maxilla and mandible with implant supported fixed prostheses using monolithic zirconia, where the incisal edges and occluding surfaces were made of monolithic zirconia. Edentulism is a debilitating condition that can be treated with either a removable or fixed dental prosthesis. The most common type of implant-supported fixed prosthesis is the metal acrylic (hybrid), with ceramo-metal prostheses being used less commonly in complete edentulism. However, both of these prostheses designs are associated with reported complications of screw loosening or fracture and chipping of acrylic resin and porcelain. Monolithic zirconia implant-supported fixed prostheses have the potential for reduction of such complications. In this case, the CAD/CAM concept was utilized in fabrication of maxillary and mandibular screw-retained implant-supported fixed prostheses using monolithic zirconia. Proper treatment planning and execution coupled with utilizing advanced technologies contributes to highly esthetic results. However, long-term studies are required to guarantee a satisfactory long-term outcome of this modality of treatment. This case report describes the clinical and technical procedures involved in fabrication of maxillary and mandibular implant-supported fixed prostheses using monolithic zirconia as a treatment of edentulism, and proposes the possible advantages associated with using monolithic zirconia in eliminating dissimilar interfaces in such prostheses that are accountable for the most commonly occurring technical complication for these prostheses being chipping and fracture of the veneering material. © 2015 Wiley Periodicals, Inc.
Rotator Cuff Deficient Arthritis of the Glenohumeral Joint
Macaulay, Alec A.; Greiwe, R. Michael
2010-01-01
Rotator cuff deficient arthritis of the glenohumeral joint, especially cuff tear arthropathy, has proved a challenging clinical entity for orthopaedic surgeons ever since Charles Neer originally detailed the problem in 1983. Understanding has improved regarding the pathophysiology and pathomechanics underlying cuff tear arthropathy. Surgical reconstruction options can lead to excellent outcomes for patients afflicted with these painful and functionally limited shoulders. Humeral hemiarthroplasty and reverse total shoulder arthroplasty have jumped to the forefront in the treatment of cuff tear arthropathy. As studies continue to look at the results of these procedures in cuff tear arthropathy, existing indications and treatment algorithms will be further refined. In this article the history and pathophysiology of cuff tear arthropathy are reviewed. Additionally, the clinical findings and results of surgical reconstruction are discussed. PMID:21119934
Microbial biofilms on facial prostheses.
Ariani, Nina; Vissink, Arjan; van Oort, Robert P; Kusdhany, Lindawati; Djais, Ariadna; Rahardjo, Tri Budi W; van der Mei, Henny C; Krom, Bastiaan P
2012-01-01
The composition of microbial biofilms on silicone rubber facial prostheses was investigated and compared with the microbial flora on healthy and prosthesis-covered skin. Scanning electron microscopy showed the presence of mixed bacterial and yeast biofilms on and deterioration of the surface of the prostheses. Microbial culturing confirmed the presence of yeasts and bacteria. Microbial colonization was significantly increased on prosthesis-covered skin compared to healthy skin. Candida spp. were exclusively isolated from prosthesis-covered skin and from prostheses. Biofilms from prostheses showed the least diverse band-profile in denaturing gradient gel electrophoresis (DGGE) whereas prosthesis-covered skin showed the most diverse band-profile. Bacterial diversity exceeded yeast diversity in all samples. It is concluded that occlusion of the skin by prostheses creates a favorable niche for opportunistic pathogens such as Candida spp. and Staphylococcus aureus. Biofilms on healthy skin, skin underneath the prosthesis and on the prosthesis had a comparable composition, but the numbers present differed according to the microorganism.
Torrens, Carlos; Alentorn-Geli, Eduard; Mingo, Felipe; Gamba, Carlo; Santana, Fernando
2018-01-01
To investigate the influence of greater tuberosity healing on the functional outcomes of reverse shoulder arthroplasty (RSA) for the treatment of acute complex proximal humeral fractures (PHFs), and to investigate the influence of patient- and surgery-related factors in the healing of the greater tuberosity. Retrospective study including 41 consecutive PHFs treated using RSA with minimum 2-year follow-up. In all the cases, tuberosities were reattached with a standardized technique. All the patients were assessed at the last follow-up with constant score. Body mass index, surgery delay, comorbidities, polyethylene size, glenosphere size, overhanging of glenosphere, and scapular notch were recorded, and their influence in final constant score and in greater tuberosity healing was analyzed. Mean final constant score was of 60.7 points (standard deviation (SD) = 9.9). Greater tuberosity healed in proper position in 68% of the cases. There were no significant differences in constant score between patients with (mean = 61; SD = 9.5) and without (mean = 61; SD = 11.3) the healing of greater tuberosity. All patients scored above 90° in forward elevation. Scapular notch was reported in 14.6% of the cases. Age significantly affected the constant score ( p = 0.008). Comorbidities significantly interfered with greater tuberosity healing ( p = 0.03). There was one reoperation after dislocation. In spite of expecting good functional outcome with low complication rate after RSA for acute PHFs, the influence of greater tuberosity healing on shoulder function could not be demonstrated. The presence of comorbidities, but not age or gender, negatively influenced the healing of the greater tuberosity.
Optimal screw placement for base plate fixation in reverse total shoulder arthroplasty.
DiStefano, James Guido; Park, Andrew Y; Nguyen, Thuc-Quyen D; Diederichs, Gerd; Buckley, Jenni M; Montgomery, William H
2011-04-01
Scapular cortical thickness has not been fully characterized from the perspective of determining optimal screw placement for securing the glenoid base plate in reverse shoulder arthroplasty. Twelve fresh frozen cadaveric scapulae underwent high resolution CT scans with 3-dimensional reconstructions and wall thickness analysis. Digital base plates were positioned and virtual screws were placed according to 2 scenarios: A - intraosseous through the entire course and exits a "safe region" with no known neurovascular structures; B - may leave and re-enter the bone and penetrates the thickest cortical region accessible regardless of adjacent structures. For scenario A, the optimal screw configurations were: (superior screw) length = 35 mm, 9° superior, 2° posterior; (inferior screw-A) length = 34 mm, 16° inferior, 5° anterior; (inferior screw-B) length = 31 mm, 31 inferior, 4 posterior; (posterior screw) length 19 mm, 29° inferior, 3° anterior. For scenario B: (superior screw) length = 36 mm, 28° superior, 10° anterior; (inferior screw) length = 35 mm, 19° inferior, 4° anterior; (posterior screw) length 37 mm, 23° superior, 3° anterior. The anterior screw was consistent between scenarios A and B, averaged 29 mm in length and was directed 16° inferior and 14° posterior. Thicker cortical regions were present in the lateral aspect of the suprascapular notch, scapular spine base, anterior/superior aspect of inferior pillar and junction of glenoid neck and scapular spine. Regions with high cortical thickness were accessible for both scenarios except for the posterior screw in scenario A. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Stephens, Byron F; Hebert, Casey T; Azar, Frederick M; Mihalko, William M; Throckmorton, Thomas W
2015-09-01
Baseplate loosening in reverse total shoulder arthroplasty (RTSA) remains a concern. Placing peripheral screws into the 3 pillars of the densest scapular bone is believed to optimize baseplate fixation. Using a 3-dimensional computer-aided design (3D CAD) program, we investigated the optimal rotational baseplate alignment to maximize peripheral locking-screw purchase. Seventy-three arthritic scapulae were reconstructed from computed tomography images and imported into a 3D CAD software program along with representations of an RTSA baseplate that uses 4 fixed-angle peripheral locking screws. The baseplate position was standardized, and the baseplate was rotated to maximize individual and combined peripheral locking-screw purchase in each of the 3 scapular pillars. The mean ± standard error of the mean positions for optimal individual peripheral locking-screw placement (referenced in internal rotation) were 6° ± 2° for the coracoid pillar, 198° ± 2° for the inferior pillar, and 295° ± 3° for the scapular spine pillar. Of note, 78% (57 of 73) of the screws attempting to obtain purchase in the scapular spine pillar could not be placed without an in-out-in configuration. In contrast, 100% of coracoid and 99% of inferior pillar screws achieved full purchase. The position of combined maximal fixation was 11° ± 1°. These results suggest that approximately 11° of internal rotation is the ideal baseplate position for maximal peripheral locking-screw fixation in RTSA. In addition, these results highlight the difficulty in obtaining optimal purchase in the scapular spine. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Quantification of dental prostheses on cone‐beam CT images by the Taguchi method
Kuo, Rong‐Fu; Fang, Kwang‐Ming; TY, Wong
2016-01-01
The gray values accuracy of dental cone‐beam computed tomography (CBCT) is affected by dental metal prostheses. The distortion of dental CBCT gray values could lead to inaccuracies of orthodontic and implant treatment. The aim of this study was to quantify the effect of scanning parameters and dental metal prostheses on the accuracy of dental cone‐beam computed tomography (CBCT) gray values using the Taguchi method. Eight dental model casts of an upper jaw including prostheses, and a ninth prosthesis‐free dental model cast, were scanned by two dental CBCT devices. The mean gray value of the selected circular regions of interest (ROIs) were measured using dental CBCT images of eight dental model casts and were compared with those measured from CBCT images of the prosthesis‐free dental model cast. For each image set, four consecutive slices of gingiva were selected. The seven factors (CBCTs, occlusal plane canting, implant connection, prosthesis position, coping material, coping thickness, and types of dental restoration) were used to evaluate scanning parameter and dental prostheses effects. Statistical methods of signal to noise ratio (S/N) and analysis of variance (ANOVA) with 95% confidence were applied to quantify the effects of scanning parameters and dental prostheses on dental CBCT gray values accuracy. For ROIs surrounding dental prostheses, the accuracy of CBCT gray values were affected primarily by implant connection (42%), followed by type of restoration (29%), prostheses position (19%), coping material (4%), and coping thickness (4%). For a single crown prosthesis (without support of implants) placed in dental model casts, gray value differences for ROIs 1–9 were below 12% and gray value differences for ROIs 13–18 away from prostheses were below 10%. We found the gray value differences set to be between 7% and 8% for regions next to a single implant‐supported titanium prosthesis, and between 46% and 59% for regions between double implant‐supported, nickel‐chromium alloys (Ni‐Cr) prostheses. Quantification of the effect of prostheses and scanning parameters on dental CBCT gray values was assessed. PACS numbers: 87.59.bd, 87.57Q PMID:26894354
Kim, Sung-Jae; Choi, Yun-Rak; Jung, Min; Lee, Won-Yong; Chun, Yong-Min
2017-05-01
No previous study has examined whether isolated subscapularis tendon repair in irreparable posterosuperior massive rotator tears involving the subscapularis tendon in relatively young patients without arthritis can yield satisfactory outcomes. We hypothesized that this procedure would produce favorable outcomes in patients who might otherwise be candidates for reverse arthroplasty. Case series; Level of evidence, 4. This retrospective study included 24 patients in their 50s and 60s, without shoulder arthritis, who underwent arthroscopic isolated subscapularis repair for an irreparable massive rotator cuff tear involving the subscapularis tendon. Preoperative and postoperative visual analog scale (VAS) pain scores, subjective shoulder values (SSVs), University of California at Los Angeles (UCLA) shoulder scores, American Shoulder and Elbow Surgeons (ASES) scores, subscapularis strength (modified bell-press test; maximum of 5), and shoulder active range of motion (ROM) were assessed. Postoperative magnetic resonance arthrography (MRA) was performed 6 months postoperatively to assess structural integrity of the repaired subscapularis. At a mean 34.8 months (range, 24-49 months) of follow-up, VAS pain scores (improved from 7.1 to 2.5), SSVs (33.3 to 75.2), ASES scores (35.9 to 76.0), UCLA shoulder scores (11.6 to 24.8), subscapularis strength, and ROM were significantly improved compared with preoperative measurements ( P < .001). Subscapularis muscle strength improved from 3.7 to 4.2 ( P < .001). For active ROM, forward flexion and internal rotation improved significantly ( P < .001); however, external rotation exhibited no significant improvement. Follow-up MRA was performed in 22 patients (92%) and showed retear of the repaired subscapularis in 6 (27% of the 22). Isolated repair of the subscapularis tendon in irreparable massive rotator cuff tears involving the subscapularis tendon yielded satisfactory short-term outcomes and structural integrity in patients in their 50s and 60s without arthritis. If patients with irreparable massive rotator cuff tears involving the subscapularis tendon are relatively young or have minimal concomitant arthritis, this repair can be worthwhile.
Evaluation of metal-polymeric fixed partial prosthesis using optical coherence tomography
NASA Astrophysics Data System (ADS)
Sinescu, C.; Negrutiu, M. L.; Duma, V. F.; Marcauteanu, C.; Topala, F. I.; Rominu, M.; Bradu, A.; Podoleanu, A. Gh.
2013-11-01
Metal-Polymeric fixed partial prosthesis is the usual prosthetic treatment for many dental patients. However, during the mastication the polymeric component of the prosthesis is fractured and will be lost. This fracture is caused by the material defects or by the fracture lines trapped inside the esthetic components of the prosthesis. This will finally lead to the failure of the prosthetic treatment. Nowadays, there is no method of identification and forecast for the materials defects of the polymeric materials. The aim of this paper is to demonstrate the capability of Optical Coherence Tomography (OCT) as a non-invasive clinical method that can be used for the evaluation of metal-polymeric fixed partial prostheses. Twenty metal-polymeric fixed partial prostheses were used for this study. The esthetic component of the prostheses has been Adoro (Ivoclar). Optical investigations of the metal prostheses have revealed no material defects or fracture lines. All the prostheses were temporary cemented in the oral cavities of the patients for six month. The non-invasive method used for the investigations was OCT working in Time Domain mode at 1300 nm. The evaluations of the prostheses were performed before and after their cementation in the patient mouths. All the imagistic results were performed in 2D and than in 3D, after the reconstruction. The results obtained after the OCT evaluation allowed for the identification of 4 metal-polymeric fixed partial prostheses with material defects immediately after finishing the technological procedures. After 6 month in the oral environment other 3 fixed partial prostheses revealed fracture lines. In conclusion, OCT proved to be a valuable tool for the noninvasive evaluation of the metal-polymeric fixed partial prostheses.
Hjalmarsson, Lars; Smedberg, Jan-Ivan; Pettersson, Mattias; Jemt, Torsten
2011-01-01
Long-term comparisons of frameworks at the implant or abutment level are not available, and knowledge of the clinical function of cobalt-chromium (Co-Cr) alloy frameworks is limited. Primarily, the aim of this study was to compare the 5-year clinical performance of frameworks with or without abutment connections to implants. Secondly, the outcomes of prostheses made from Co-Cr alloy with porcelain veneers to those made of commercially pure titanium (CP Ti) with acrylic veneers were compared. The test groups comprised patients treated with screw-retained fixed prostheses made at the implant level according to the Cresco method in either dental porcelain-veneered Co-Cr alloy (n = 15) or acrylic-veneered CP Ti (n = 25). A control group of 40 randomly selected patients were provided with prostheses made at the standard abutment level in CP Ti with acrylic veneers. For all patients, clinical and radiologic 5-year data were retrospectively collected and evaluated. Five-year implant cumulative survival rates (CSRs) were 98.6% and 97.6% for test and control groups, respectively (P > .05). No major differences in bone level were demonstrated between the groups after 5 years (P > .05). Significantly more complications occurred in the test groups compared to the control group (P < .01), with the most common complications being mucositis and fracture of veneers. After 5 years, the clinical outcomes of implant-level prostheses made of porcelain-veneered Co-Cr or acrylic-veneered CP Ti seem comparable to acrylic-veneered titanium prostheses made at the standard abutment level regarding implant CSR and bone levels. However, more complications were registered in implant-level prostheses compared to the standard abutment-level prostheses.
de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Duchateau, Luc; Cox, Eric
2007-09-01
To examine mRNA expression of cytokines in synovial fluid (SF) cells from dogs with cranial cruciate ligament (CrCL) rupture and medial patellar luxation (MPL) and determine mRNA expression for 3 joints (affected stifle, unaffected contralateral stifle, and left shoulder joints) in dogs with unilateral CrCL rupture. 29 stifle joints with CrCL rupture (29 dogs), 8 stifle joints with MPL (7 dogs), and 24 normal stifle joints (16 clinically normal dogs). Immediately before reconstructive surgery, SF was aspirated from the cruciate-deficient stifle joint or stifle joint with MPL. Fourteen of 29 dogs had unilateral CrCL rupture; SF was also aspirated from the unaffected contralateral stifle joint and left shoulder joint. Those 14 dogs were examined 6 and 12 months after reconstructive surgery. Total RNA was extracted from SF cells and reverse transcription-PCR assay was performed to obtain cDNA. Canine-specific cytokine mRNA expression was determined by use of a real-time PCR assay. Interleukin (IL)-8 and -10 and interferon-gamma expression differed significantly between dogs with arthropathies and dogs with normal stifle joints. For the 14 dogs with unilateral CrCL rupture, a significant difference was found for IL-8 expression. Before reconstructive surgery, IL-8 expression differed significantly between the affected stifle joint and left shoulder joint or contralateral stifle joint. Six months after surgery, IL-8 expression was significantly increased in the unaffected contralateral stifle joint, compared with the shoulder joint. No conclusions can be made regarding the role of the examined cytokines in initiation of CrCL disease.
Fabrication of low cost soft tissue prostheses with the desktop 3D printer
NASA Astrophysics Data System (ADS)
He, Yong; Xue, Guang-Huai; Fu, Jian-Zhong
2014-11-01
Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods.
Fabrication of low cost soft tissue prostheses with the desktop 3D printer
He, Yong; Xue, Guang-huai; Fu, Jian-zhong
2014-01-01
Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods. PMID:25427880
A Powered Prosthetic Intervention for Bilateral Transfemoral Amputees
Lawson, Brian E.; Ruhe, Brian; Shultz, Amanda; Goldfarb, Michael
2014-01-01
This paper presents the design and validation of a control system for a pair of powered knee and ankle prostheses to be used as a prosthetic intervention for bilateral transfemoral amputees. The control system leverages communication between the prostheses for enhanced awareness and stability, along with power generation at the knee and ankle joints to better restore biomechanical functionality in level ground walking. The control methodology employed is a combination of an impedance-based framework for weight-bearing portions of gait and a trajectory-based approach for the non-weight-bearing portions. The control system was implemented on a pair of self-contained powered knee and ankle prostheses, and the ability of the prostheses and control approach to provide walking functionality was assessed in a set of experimental trials with a bilateral transfemoral amputee subject. Specifically, experimental data from these trials indicate that the powered prostheses and bilateral control architecture provide gait kinematics that reproduce healthy gait kinematics to a greater extent than the subject’s daily-use passive prostheses. PMID:25014950
NASA Astrophysics Data System (ADS)
Sgambitterra, Emanuele; Piccininni, Antonio; Guglielmi, Pasquale; Ambrogio, Giuseppina; Fragomeni, Gionata; Villa, Tomaso; Palumbo, Gianfranco
2018-05-01
Cranial implants are custom prostheses characterized by quite high geometrical complexity and small thickness; at the same time aesthetic and mechanical requirements have to be met. Titanium alloys are largely adopted for such prostheses, as they can be processed via different manufacturing technologies. In the present work cranial prostheses have been manufactured by Super Plastic Forming (SPF) and Single Point Incremental Forming (SPIF). In order to assess the mechanical performance of the cranial prostheses, drop tests under different load conditions were conducted on flat samples to investigate the effect of the blank thickness. Numerical simulations were also run for comparison purposes. The mechanical performance of the cranial implants manufactured by SPF and SPIF could be predicted using drop test data and information about the thickness evolution of the formed parts: the SPIFed prosthesis revealed to have a lower maximum deflection and a higher maximum force, while the SPFed prostheses showed a lower absorbed energy.
Fabrication of low cost soft tissue prostheses with the desktop 3D printer.
He, Yong; Xue, Guang-huai; Fu, Jian-zhong
2014-11-27
Soft tissue prostheses such as artificial ear, eye and nose are widely used in the maxillofacial rehabilitation. In this report we demonstrate how to fabricate soft prostheses mold with a low cost desktop 3D printer. The fabrication method used is referred to as Scanning Printing Polishing Casting (SPPC). Firstly the anatomy is scanned with a 3D scanner, then a tissue casting mold is designed on computer and printed with a desktop 3D printer. Subsequently, a chemical polishing method is used to polish the casting mold by removing the staircase effect and acquiring a smooth surface. Finally, the last step is to cast medical grade silicone into the mold. After the silicone is cured, the fine soft prostheses can be removed from the mold. Utilizing the SPPC method, soft prostheses with smooth surface and complicated structure can be fabricated at a low cost. Accordingly, the total cost of fabricating ear prosthesis is about $30, which is much lower than the current soft prostheses fabrication methods.
Hip prostheses in young adults. Surface prostheses and short-stem prostheses.
Gallart, X; Riba, J; Fernández-Valencia, J A; Bori, G; Muñoz-Mahamud, E; Combalia, A
The poor results obtained in young patients when using a conventional prosthesis led to the resurgence of hip resurfacing to find less invasive implants for the bone. Young patients present a demand for additional activity, which makes them a serious challenge for the survival of implants. In addition, new information technologies contribute decisively to the preference for non-cemented prostheses. Maintaining quality of life, preserving the bone and soft tissues, as well as achieving a very stable implant, are the goals of every hip orthopaedic surgeon for these patients. The results in research point to the use of smaller prostheses, which use the metaphyseal zone more and less the diaphyseal zone, and hence the large number of the abovementioned short stem prostheses. Both models are principally indicated in the young adult. Their revision should be a more simple operation, but this is only true for hip resurfacing, not for short stems. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Ghoseiri, Kamiar; Zheng, Yong Ping; Leung, Aaron K L; Rahgozar, Mehdi; Aminian, Gholamreza; Masoumi, Mehdi; Safari, Mohammad Reza
2018-01-01
The snug fit of a prosthetic socket over the residual limb can disturb thermal balance and put skin integrity in jeopardy by providing an unpleasant and infectious environment. The prototype of a temperature measurement and control (TM&C) system was previously introduced to resolve thermal problems related to prostheses. This study evaluates its clinical application in a setting with reversal, single subject design. The TM&C system was installed on a fabricated prosthetic socket of a man with unilateral transtibial amputation. Skin temperature of the residual limb without prosthesis at baseline and with prosthesis during rest and walking was evaluated. The thermal sense and thermal comfort of the participant were also evaluated. The results showed different skin temperature around the residual limb with a temperature decrease tendency from proximal to distal. The TM&C system decreased skin temperature rise after prosthesis wearing. The same situation occurred during walking, but the thermal power of the TM&C system was insufficient to overcome heat build-up in some regions of the residual limb. The participant reported no significant change of thermal sense and thermal comfort. Further investigations are warranted to examine thermography pattern of the residual limb, thermal sense, and thermal comfort in people with amputation.
New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations
Romero, Luis; Jiménez, Mariano; Espinosa, María del Mar; Domínguez, Manuel
2015-01-01
Aim This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system. Method From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data. Results Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants. PMID:26696528
New Design for Rapid Prototyping of Digital Master Casts for Multiple Dental Implant Restorations.
Romero, Luis; Jiménez, Mariano; Espinosa, María Del Mar; Domínguez, Manuel
2015-01-01
This study proposes the replacement of all the physical devices used in the manufacturing of conventional prostheses through the use of digital tools, such as 3D scanners, CAD design software, 3D implants files, rapid prototyping machines or reverse engineering software, in order to develop laboratory work models from which to finish coatings for dental prostheses. Different types of dental prosthetic structures are used, which were adjusted by a non-rotatory threaded fixing system. From a digital process, the relative positions of dental implants, soft tissue and adjacent teeth of edentulous or partially edentulous patients has been captured, and a maser working model which accurately replicates data relating to the patients oral cavity has been through treatment of three-dimensional digital data. Compared with the conventional master cast, the results show a significant cost savings in attachments, as well as an increase in the quality of reproduction and accuracy of the master cast, with the consequent reduction in the number of patient consultation visits. The combination of software and hardware three-dimensional tools allows the optimization of the planning of dental implant-supported rehabilitations protocol, improving the predictability of clinical treatments and the production cost savings of master casts for restorations upon implants.
Early results of Latitude primary total elbow replacement with a minimum follow-up of 2 years.
Mehta, Saurabh S; Watts, Adam C; Talwalkar, Sumedh C; Birch, Ann; Nuttall, David; Trail, Ian A
2017-10-01
The aim of this study was to present outcomes of primary Latitude total elbow replacement (TER) with a minimum follow-up of 2 years. A retrospective cohort study was undertaken with prospective outcome data collection for the latest outcome. Included were 63 consecutive primary Latitude TERs in 58 patients performed during a period of 5 years at a specialist orthopedic hospital. The mean age of the patients was 62 years (33-85 years). Five primary TERs (4 patients) were lost to follow-up. The primary diagnosis was rheumatoid arthritis in 49, osteoarthritis in 8, and trauma in 6 elbows. The mean flexion-extension arc was 75° preoperatively and 97° postoperatively. Mean postoperative Elbex pain score was 19/100, and function score was 37/100. Mean postoperative scores were 42/100 for the Quick Disabilities of the Arm, Shoulder, and Hand and 38/50 for the elbow-specific American Shoulder and Elbow Surgeons assessment. Four patients died of unrelated causes, and 8 of 63 underwent further surgical intervention, including explantation and conversion from unlinked to linked implant. On radiographic review of 41 surviving TERs, aseptic radiologic loosening was observed of the humeral component in 4 elbows and of the ulnar component in 9. Seven elbows had no radial component, and of the remaining 34 elbows, 16 (47%) had signs of loosening of the radial implant. Complications included 1 heterotopic ossification, 1 olecranon fracture, and 3 further procedures for ulnar nerve entrapment. The results indicate that the early outcome of Latitude TER is comparable to that of other prostheses. There is concern about early radiologic loosening of the radial component. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Matsen, Frederick A; Russ, Stacy M; Vu, Phuong T; Hsu, Jason E; Lucas, Robert M; Comstock, Bryan A
2016-11-01
Although shoulder arthroplasties generally are effective in improving patients' comfort and function, the results are variable for reasons that are not well understood. We posed two questions: (1) What factors are associated with better 2-year outcomes after shoulder arthroplasty? (2) What are the sensitivities, specificities, and positive and negative predictive values of a multivariate predictive model for better outcome? Three hundred thirty-nine patients having a shoulder arthroplasty (hemiarthroplasty, arthroplasty for cuff tear arthropathy, ream and run arthroplasty, total shoulder or reverse total shoulder arthroplasty) between August 24, 2010 and December 31, 2012 consented to participate in this prospective study. Two patients were excluded because they were missing baseline variables. Forty-three patients were missing 2-year data. Univariate and multivariate analyses determined the relationship of baseline patient, shoulder, and surgical characteristics to a "better" outcome, defined as an improvement of at least 30% of the maximal possible improvement in the Simple Shoulder Test. The results were used to develop a predictive model, the accuracy of which was tested using a 10-fold cross-validation. After controlling for potentially relevant confounding variables, the multivariate analysis showed that the factors significantly associated with better outcomes were American Society of Anesthesiologists Class I (odds ratio [OR], 1.94; 95% CI, 1.03-3.65; p = 0.041), shoulder problem not related to work (OR, 5.36; 95% CI, 2.15-13.37; p < 0.001), lower baseline Simple Shoulder Test score (OR, 1.32; 95% CI, 1.23-1.42; p < 0.001), no prior shoulder surgery (OR, 1.79; 95% CI, 1.18-2.70; p = 0.006), humeral head not superiorly displaced on the AP radiograph (OR, 2.14; 95% CI, 1.15-4.02; p = 0.017), and glenoid type other than A1 (OR, 4.47; 95% CI, 2.24-8.94; p < 0.001). Neither preoperative glenoid version nor posterior decentering of the humeral head on the glenoid were associated with the outcomes. The model predictive of a better result was driven mainly by the six factors listed above. The area under the receiver operating characteristic curve generated from the cross-validated enhanced predictive model was 0.79 (generally values of 0.7 to 0.8 are considered fair and values of 0.8 to 0.9 are considered good). The false-positive fraction and the true-positive fraction depended on the cutoff probability selected (ie, the selected probability above which the prediction would be classified as a better outcome). A cutoff probability of 0.68 yielded the best performance of the model with cross-validation predictions of better outcomes for 236 patients (80%) and worse outcomes for 58 patients (20%); sensitivity of 91% (95% CI, 88%-95%); specificity of 65% (95% CI, 53%-77%); positive predictive value of 92% (95% CI, 88%-95%); and negative predictive value of 64% (95% CI, 51%-76%). We found six easy-to-determine preoperative patient and shoulder factors that were significantly associated with better outcomes of shoulder arthroplasty. A model based on these characteristics had good predictive properties for identifying patients likely to have a better outcome from shoulder arthroplasty. Future research could refine this model with larger patient populations from multiple practices. Level II, therapeutic study.
Chou, Justin; Malak, Sharif F; Anderson, Iain A; Astley, Tim; Poon, Peter C
2009-01-01
Reverse total shoulder arthroplasty is a treatment option for cuff tear arthropathy. Scapular notching remains a concern. This biomechanical study compared the range-of-motion in different designs of glenospheres and hence the relative risk of scapular notching. A precision coordinate device was used to investigate four different designs of glenospheres (SMR prosthesis); 36 mm concentric (Standard), 36 mm eccentric, 44 mm concentric, and 44 mm eccentric glenospheres. The centre of rotation in each design was first established. The position of the humeral prosthesis was recorded in the plane of the scapula to compare the degree of adduction and the total range-of-motion. Eccentric glenospheres were found to improve range-of-motion by allowing a higher degree of adduction. Larger diameter glenospheres were found to improve range-of-motion by increasing adduction and abduction. Compared to the 36 mm concentric (standard) glenosphere, the 36 mm eccentric glenosphere improved adduction by 14.5 degrees, the 44 mm concentric glenosphere improved adduction by 11.6 degrees, the 44 mm eccentric glenosphere improved adduction by 17.7 degrees. Eccentric glenospheres with a center-of-rotation placed more inferiorly were shown to improve adduction. This design may reduce the clinical incidence of scapular notching.
Composite Materials for Maxillofacial Prostheses.
1981-08-01
necessary and Identify byv block number) MAXILLOFACIAL PROSTHESES; PROSTHETIC MATERIALS: MICROCAPSULES : SOFT FILLERS; ELASTOMER COMPOSITES 2,. ABSTRACT...used as fillers in the fabrication of maxillofacial prostheses. The projected systems are elastomeric-shelled, liquid-filled microcapsules . Improvements...elastomeric-shelled, liquid-filled microcapsules . Experiments continued on the interfacial polymerization process, with spherical, sealed, capsules
Morphological characterization of dental prostheses interfaces using optical coherence tomography
NASA Astrophysics Data System (ADS)
Sinescu, Cosmin; Negrutiu, Meda L.; Ionita, Ciprian; Marsavina, Liviu; Negru, Radu; Caplescu, Cristiana; Bradu, Adrian; Topala, Florin; Rominu, Roxana O.; Petrescu, Emanuela; Leretter, Marius; Rominu, Mihai; Podoleanu, Adrian G.
2010-03-01
Fixed partial prostheses as integral ceramic, polymers, metal-ceramic or metal-polymers bridges are mainly used in the frontal part of the dental arch (especially the integral bridges). They have to satisfy high stress as well as esthetic requirements. The masticatory stress may induce fractures of the bridges. These may be triggered by initial materials defects or by alterations of the technological process. The fractures of these bridges lead to functional, esthetic and phonetic disturbances which finally render the prosthetic treatment inefficient. Dental interfaces represent one of the most significant aspects in the strength of the dental prostheses under the masticatory load. The purpose of this study is to evaluate the capability of optical coherence tomography (OCT) to characterize the dental prostheses interfaces. The materials used were several fixed partial prostheses integral ceramic, polymers, metal-ceramic and metal-polymers bridges. It is important to produce both C-scans and B-scans of the defects in order to differentiate morphological aspects of the bridge infrastructures. The material defects observed with OCT were investigated with micro-CT in order to prove their existence and positions. In conclusion, it is important to have a non invasive method to investigate dental prostheses interfaces before the insertion of prostheses in the oral cavity.
[Clinical evaluation of "All-on-Four" provisional prostheses reinforced with carbon fibers].
Li, Bei-bei; Lin, Ye; Cui, Hong-yan; Hao, Qiang; Xu, Jia-bin; Di, Ping
2016-02-18
To assess the clinical effects of carbon fiber reinforcement on the "All-on-Four" provisional prostheses. Provisional prostheses were divided into control group and carbon fiber reinforcing group according to whether carbon fiber reinforcement was used in the provisional prostheses base resin. In our study, a total of 60 patients (32 males and 28 females) with 71 provisional prostheses(28 maxilla and 43 mandible)were enrolled between April 2008 and December 2012 for control group; a total of 23 patients (13 males and 10 females) with 28 provisional prostheses (9 maxillas and 19 mandibles) were enrolled between January 2013 and March 2014 for carbon fiber reinforcing group. The information of provisional prostheses in the patients was recorded according to preoperative examination. We used the date of definitive prosthesis restoration as the cut-off point, observing whether fracture occurred on the provisional prostheses in the two groups. Additionally we observed whether fiber exposure occurred on the tissue surface of the provisional prostheses and caused mucosal irritation. The interface between the denture base resin and the fibers was examined using scanning electron microscopy (SEM). The age [(57.3 ± 10.1) years vs.(55.1 ± 11.4) years], gender (32 males and 28 females vs. 13 males and 10 females), maxilla and mandible distributions (28 maxillas and 43 mandibles vs. 9 maxillas and 19 mandibles), the number of extraction jaws (46 vs. 23), the average using time [(7.8 ± 1.3) months vs. (7.5 ± 1.1) months], and the opposing dentition distributions of provisional prostheses of the patients showed no significant differences between the control and reinforcing groups. There were 21(29.6%) fractures that occurred on the 71 provisional prostheses in the control group; there was no fracture that occurred on the 28 provisional prosthesesin the carbon fiber reinforcing group. The fracture rate of the carbon fiber reinforcing group was significantly lower than that of the control group (P=0.001). No carbon fiber exposure and mucosal irritation were observed from clinical examination.SEM revealed relatively continuous contact between the fiber and acrylic resin, and the resin particles adhered on the surface of the carbon fibers. The addition of carbon fibers between abutments placed on "All-on-Four" provisional fixed denture base resin may be clinically effective in preventing "All-on-Four" denture fracture and can provide several advantages for clinical use.
Characterizing the Mechanical Properties of Running-Specific Prostheses
Beck, Owen N.; Taboga, Paolo; Grabowski, Alena M.
2016-01-01
The mechanical stiffness of running-specific prostheses likely affects the functional abilities of athletes with leg amputations. However, each prosthetic manufacturer recommends prostheses based on subjective stiffness categories rather than performance based metrics. The actual mechanical stiffness values of running-specific prostheses (i.e. kN/m) are unknown. Consequently, we sought to characterize and disseminate the stiffness values of running-specific prostheses so that researchers, clinicians, and athletes can objectively evaluate prosthetic function. We characterized the stiffness values of 55 running-specific prostheses across various models, stiffness categories, and heights using forces and angles representative of those measured from athletes with transtibial amputations during running. Characterizing prosthetic force-displacement profiles with a 2nd degree polynomial explained 4.4% more of the variance than a linear function (p<0.001). The prosthetic stiffness values of manufacturer recommended stiffness categories varied between prosthetic models (p<0.001). Also, prosthetic stiffness was 10% to 39% less at angles typical of running 3 m/s and 6 m/s (10°-25°) compared to neutral (0°) (p<0.001). Furthermore, prosthetic stiffness was inversely related to height in J-shaped (p<0.001), but not C-shaped, prostheses. Running-specific prostheses should be tested under the demands of the respective activity in order to derive relevant characterizations of stiffness and function. In all, our results indicate that when athletes with leg amputations alter prosthetic model, height, and/or sagittal plane alignment, their prosthetic stiffness profiles also change; therefore variations in comfort, performance, etc. may be indirectly due to altered stiffness. PMID:27973573
Rapid prototyping--when virtual meets reality.
Beguma, Zubeda; Chhedat, Pratik
2014-01-01
Rapid prototyping (RP) describes the customized production of solid models using 3D computer data. Over the past decade, advances in RP have continued to evolve, resulting in the development of new techniques that have been applied to the fabrication of various prostheses. RP fabrication technologies include stereolithography (SLA), fused deposition modeling (FDM), computer numerical controlled (CNC) milling, and, more recently, selective laser sintering (SLS). The applications of RP techniques for dentistry include wax pattern fabrication for dental prostheses, dental (facial) prostheses mold (shell) fabrication, and removable dental prostheses framework fabrication. In the past, a physical plastic shape of the removable partial denture (RPD) framework was produced using an RP machine, and then used as a sacrificial pattern. Yet with the advent of the selective laser melting (SLM) technique, RPD metal frameworks can be directly fabricated, thereby omitting the casting stage. This new approach can also generate the wax pattern for facial prostheses directly, thereby reducing labor-intensive laboratory procedures. Many people stand to benefit from these new RP techniques for producing various forms of dental prostheses, which in the near future could transform traditional prosthodontic practices.
[Effect of CO2 laser on prostheses used in middle ear surgery].
Szymański, Marcin
2005-01-01
The use of CO2 laser is advocated in primary and revision stapes surgery. The aim of the study was to assess the effect of CO2 laser on stapes prostheses. CO2 laser was applied on several types of stapes prostheses and PORPs, with power settings suggested by the manufacturer (continuous wave, 2 W and 6 W; 0,05 s). Application of the laser on stainless steel or titanium prosthesis did not exert any effect on the structure of the prosthesis. The use of the laser on the Teflon piston caused superficial burning with power 2 W, and melting and holes in the piston with power settings at 6W. Similar plastipore prostheses were melting. Hydroxyapatite PORP shattered after application of the laser energy. Teflon and hydroxyapatite prostheses are easily damaged by the laser energy, therefore applying a laser on them should be avoided. CO2 laser can be used on stainless steel and titanium prostheses without risk of damaging them. However the possibility of transmission of heat to the vestibule has to be taken into consideration.
Loza-Herrero, María A; Rivas-Tumanyan, Sona; Morou-Bermudez, Evangelia
2015-11-01
The success rate of implant-retained prostheses in a postdoctoral prosthodontics program was unknown and could not be related to any set of potential clinical issues or patient characteristics. The purpose of this study was to determine the success rate of implant-retained prostheses placed by prosthodontic residents between 1997 and 2012 and to evaluate the associations between patient classifications and specific restoration characteristics as related to prosthesis success or failure. A total of 272 prostheses in 119 patients were clinically evaluated. Success was defined as the absence of prosthetic complications or any implant-related complication that affected prosthesis survival. Logistic regression was used to evaluate associations between prosthesis success/failure and a wide array of study variables, adjusting for patient age, sex, and prosthesis longevity. The overall success rate was 71%, with a mean prosthesis age of 4.5 years (range: 4 months to 16.8 years). Implant single crowns were the most successful prosthesis type (81% success). The most common complications observed were porcelain fractures in fixed dental prostheses (15%) and lack of stability (31%) and retention (29%) in removable dental prostheses. Having a removable prosthesis (versus natural dentition) in the opposing occlusion significantly decreased the odds of success (OR=0.26, 95% CI: 0.11-0.64). Definitively cemented fixed prostheses were more successful than those cemented with an interim cement (OR=4.56, 95% CI: 1.37-15.22). The overall success rate of the implant-retained prostheses placed in the program was low compared with previously published studies. This study revealed the need for an efficient, comprehensive recall system for patients receiving implant-retained prostheses, either fixed or removable. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Fiber-reinforced composite fixed dental prostheses: two clinical reports.
Zarow, Maciej; Paisley, Carl Stuart; Krupinski, Jerzy; Brunton, Paul Anthony
2010-06-01
Various options are available in clinical practice for the replacement of a single missing tooth, ranging from conventional fixed and removable dental prostheses to a single implant-supported crown. There are situations in which a semipermanent fixed dental prosthesis may be desirable, particularly for patients who have completed orthodontic treatment but are too young to embark on implant therapy. Following advances in fiber-reinforcement technology, fiber-reinforced composite resin (FRC) now represents a lower-cost alternative to traditional metal-ceramic for the construction of resin-bonded prostheses. Two case reports illustrate the use of FRC prostheses as fixed semipermanent_restorations.
Veldkamp, Wouter J H; Joemai, Raoul M S; van der Molen, Aart J; Geleijns, Jacob
2010-02-01
Metal prostheses cause artifacts in computed tomography (CT) images. The purpose of this work was to design an efficient and accurate metal segmentation in raw data to achieve artifact suppression and to improve CT image quality for patients with metal hip or shoulder prostheses. The artifact suppression technique incorporates two steps: metal object segmentation in raw data and replacement of the segmented region by new values using an interpolation scheme, followed by addition of the scaled metal signal intensity. Segmentation of metal is performed directly in sinograms, making it efficient and different from current methods that perform segmentation in reconstructed images in combination with Radon transformations. Metal signal segmentation is achieved by using a Markov random field model (MRF). Three interpolation methods are applied and investigated. To provide a proof of concept, CT data of five patients with metal implants were included in the study, as well as CT data of a PMMA phantom with Teflon, PVC, and titanium inserts. Accuracy was determined quantitatively by comparing mean Hounsfield (HU) values and standard deviation (SD) as a measure of distortion in phantom images with titanium (original and suppressed) and without titanium insert. Qualitative improvement was assessed by comparing uncorrected clinical images with artifact suppressed images. Artifacts in CT data of a phantom and five patients were automatically suppressed. The general visibility of structures clearly improved. In phantom images, the technique showed reduced SD close to the SD for the case where titanium was not inserted, indicating improved image quality. HU values in corrected images were different from expected values for all interpolation methods. Subtle differences between interpolation methods were found. The new artifact suppression design is efficient, for instance, in terms of preserving spatial resolution, as it is applied directly to original raw data. It successfully reduced artifacts in CT images of five patients and in phantom images. Sophisticated interpolation methods are needed to obtain reliable HU values close to the prosthesis.
Schweitzer, Wolf; Thali, Michael J; Egger, David
2018-01-03
Prosthetic arm research predominantly focuses on "bionic" but not body-powered arms. However, any research orientation along user needs requires sufficiently precise workplace specifications and sufficiently hard testing. Forensic medicine is a demanding environment, also physically, also for non-disabled people, on several dimensions (e.g., distances, weights, size, temperature, time). As unilateral below elbow amputee user, the first author is in a unique position to provide direct comparison of a "bionic" myoelectric iLimb Revolution (Touch Bionics) and a customized body-powered arm which contains a number of new developments initiated or developed by the user: (1) quick lock steel wrist unit; (2) cable mount modification; (3) cast shape modeled shoulder anchor; (4) suspension with a soft double layer liner (Ohio Willowwood) and tube gauze (Molnlycke) combination. The iLimb is mounted on an epoxy socket; a lanyard fixed liner (Ohio Willowwood) contains magnetic electrodes (Liberating Technologies). An on the job usage of five years was supplemented with dedicated and focused intensive two-week use tests at work for both systems. The side-by-side comparison showed that the customized body-powered arm provides reliable, comfortable, effective, powerful as well as subtle service with minimal maintenance; most notably, grip reliability, grip force regulation, grip performance, center of balance, component wear down, sweat/temperature independence and skin state are good whereas the iLimb system exhibited a number of relevant serious constraints. Research and development of functional prostheses may want to focus on body-powered technology as it already performs on manually demanding and heavy jobs whereas eliminating myoelectric technology's constraints seems out of reach. Relevant testing could be developed to help expediting this. This is relevant as Swiss disability insurance specifically supports prostheses that enable actual work integration. Myoelectric and cosmetic arm improvement may benefit from a less forgiving focus on perfecting anthropomorphic appearance.
Silva, Kyle; Rand, Stephanie; Cancel, David; Chen, Yuxi; Kathirithamby, Rani; Stern, Michelle
2015-12-01
The lack of access to prostheses is a global problem, partially caused by the high cost associated with the current manufacturing process. Three-dimensional printing is gaining use in the medical field, and one such area is prosthetics. In addition to using cost-effective materials, this technology allows for rapid prototyping, making it an efficient solution for the development of affordable prostheses. If the rehabilitation medicine community embraces this novel technology, we can help alleviate the global disparity of access to prostheses. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
Brieler, H S; Parwaresch, R; Thiede, A
1976-01-01
Our investigations show that Sparks prostheses after subcutaneous implantation are suitable for vascular grafting. At the end of the organization period the connective tissue becomes strong, and after the third and fourth weeks collagenous and elastic fibers can be seen. Ten weeks after s.c. implantation, collagenous fibers predominate. After this the Sparks prostheses can be used as a vascular graft. Intraperitoneal implantation, however, shows a histologically different picture with characteristic findings: only fat cells can be observed, a strong granulation tissue with elastic and collagenous fibers is not present. After intraperitoneal implantation Sparks prostheses are therefore unsuitable for vascular grafts.
[Posturographic study of total prostheses in the leg. Apropos of 88 patients examined].
Lord, G; Gentaz, R; Gagey, P M; Baron, J B
1976-01-01
By suppressing certain articular sensory receptors, the reconstructive surgery of joints using total prostheses modifies tonic postural activity and, by this means, alters the regulation of balance in the subjects of operation. This doubtless explains certain discrepancies between the apparently excellent results in respect of joint movement and muscle strength and poor utilisation of the joint in every day life (instability, use of sticks or failure to use the joint in walking). Drawing on the experience and basic work of specialists in posture, the authors have undertaken a study of tonic postural activity in patients who had received a total prosthesis in the lower limb, both from the clinical aspect and by graphic measurement using an electronic apparatus, the statokinesiometer. Fourteen normal subjects were tested to calibrate the apparatus and 8 patients suffering from established osteoarthritis of the hip were studied as controls. Analysis of tonic postural activity was made in 66 patients who had received total prostheses in the lower limb. The results showed significant disturbance in balance in ankle prostheses, minimal disturbance in knee prostheses and not significant disturbance in hip prostheses. Certain therapeutic implications are derived from this study.
Ayres, S A; Holmberg, D L
1999-01-01
Pliable total ring prostheses were created from the polyvinyl chloride drip chambers of intravenous administration sets. The total ring prostheses were placed in one clinically normal research dog and in 4 client-owned dogs diagnosed with tracheal collapse. The research dog was euthanized one month after placement of the prostheses. Histopathological analysis of the trachea adjacent to the prostheses revealed a mild inflammatory response. The follow-up period for the clinical cases was from 4 months to 11 years. Radiographs taken and fluoroscopy performed 1 day to 5 months after surgery revealed improvement or resolution of the tracheal collapse. One dog was asymptomatic 28 weeks following surgery. Two dogs died 7 and 9 years after surgery, with one requiring intermittent medical management for coughing. They were euthanized for nonrespiratory illness. One dog had a persistent nonproductive cough, due to collapse of the mainstem bronchi, when last evaluated 4 months postoperatively. Pliable total ring prostheses provided adequate stability to the trachea and had the advantage of conforming to the trachea and being easy to create, place, and suture. Images Figure 1. Figure 2. PMID:10563237
A review of current surgical practice in the operative treatment of proximal humeral fractures
Jones, L. D.; Palmer, A. J. R.; Macnair, R. D.; Brewer, P. E.; Jayadev, C.; Wheelton, A. N.; Ball, D. E. J.; Nandra, R. S.; Aujla, R. S.; Sykes, A. E.; Carr, A. J.
2016-01-01
Objectives The PROximal Fracture of the Humerus: Evaluation by Randomisation (PROFHER) trial has recently demonstrated that surgery is non-superior to non-operative treatment in the management of displaced proximal humeral fractures. The objective of this study was to assess current surgical practice in the context of the PROFHER trial in terms of patient demographics, injury characteristics and the nature of the surgical treatment. Methods A total of ten consecutive patients undergoing surgery for the treatment of a proximal humeral fracture from each of 11 United Kingdom hospitals were retrospectively identified over a 15 month period between January 2014 and March 2015. Data gathered for the 110 patients included patient demographics, injury characteristics, mode of surgical fixation, the grade of operating surgeon and the cost of the surgical implants. Results A majority of the patients were female (66%, 73 of 110). The mean patient age was 62 years (range 18 to 89). A majority of patients met the inclusion criteria for the PROFHER trial (75%, 83 of 110). Plate fixation was the most common mode of surgery (68%, 75 patients), followed by intramedullary fixation (12%, 13 patients), reverse shoulder arthroplasty (10%, 11 patients) and hemiarthroplasty (7%, eight patients). The consultant was either the primary operating surgeon or supervising the operating surgeon in a large majority of cases (91%, 100 patients). Implant costs for plate fixation were significantly less than both hemiarthroplasty (p < 0.05) and reverse shoulder arthroplasty (p < 0.0001). Implant costs for intramedullary fixation were significantly less than plate fixation (p < 0.01), hemiarthroplasty (p < 0.0001) and reverse shoulder arthroplasty (p < 0.0001). Conclusions Our study has shown that the majority of a representative sample of patients currently undergoing surgical treatment for a proximal humeral fracture in these United Kingdom centres met the inclusion criteria for the PROFHER trial and that a proportion of these patients may, therefore, have been effectively managed non-operatively. Cite this article: Mr B. J. F. Dean. A review of current surgical practice in the operative treatment of proximal humeral fractures: Does the PROFHER trial demonstrate a need for change? Bone Joint Res 2016;5:178–184. DOI: 10.1302/2046-3758.55.2000596. PMID:27179004
Dean, B J F; Jones, L D; Palmer, A J R; Macnair, R D; Brewer, P E; Jayadev, C; Wheelton, A N; Ball, D E J; Nandra, R S; Aujla, R S; Sykes, A E; Carr, A J
2016-05-01
The PROximal Fracture of the Humerus: Evaluation by Randomisation (PROFHER) trial has recently demonstrated that surgery is non-superior to non-operative treatment in the management of displaced proximal humeral fractures. The objective of this study was to assess current surgical practice in the context of the PROFHER trial in terms of patient demographics, injury characteristics and the nature of the surgical treatment. A total of ten consecutive patients undergoing surgery for the treatment of a proximal humeral fracture from each of 11 United Kingdom hospitals were retrospectively identified over a 15 month period between January 2014 and March 2015. Data gathered for the 110 patients included patient demographics, injury characteristics, mode of surgical fixation, the grade of operating surgeon and the cost of the surgical implants. A majority of the patients were female (66%, 73 of 110). The mean patient age was 62 years (range 18 to 89). A majority of patients met the inclusion criteria for the PROFHER trial (75%, 83 of 110). Plate fixation was the most common mode of surgery (68%, 75 patients), followed by intramedullary fixation (12%, 13 patients), reverse shoulder arthroplasty (10%, 11 patients) and hemiarthroplasty (7%, eight patients). The consultant was either the primary operating surgeon or supervising the operating surgeon in a large majority of cases (91%, 100 patients). Implant costs for plate fixation were significantly less than both hemiarthroplasty (p < 0.05) and reverse shoulder arthroplasty (p < 0.0001). Implant costs for intramedullary fixation were significantly less than plate fixation (p < 0.01), hemiarthroplasty (p < 0.0001) and reverse shoulder arthroplasty (p < 0.0001). Our study has shown that the majority of a representative sample of patients currently undergoing surgical treatment for a proximal humeral fracture in these United Kingdom centres met the inclusion criteria for the PROFHER trial and that a proportion of these patients may, therefore, have been effectively managed non-operatively.Cite this article: Mr B. J. F. Dean. A review of current surgical practice in the operative treatment of proximal humeral fractures: Does the PROFHER trial demonstrate a need for change? Bone Joint Res 2016;5:178-184. DOI: 10.1302/2046-3758.55.2000596. © 2016 Dean et al.
Lädermann, Alexandre; Gueorguiev, Boyko; Charbonnier, Caecilia; Stimec, Bojan V.; Fasel, Jean H.D.; Zderic, Ivan; Hagen, Jennifer; Walch, Gilles
2015-01-01
Abstract Impingement after reverse shoulder arthroplasty (RSA) is believed to occur from repetitive contact in adduction between the humeral component and the inferior scapular pillar. The primary purpose of this biomechanical study was to confirm the presence of different types of impingement and to examine which daily-life movements are responsible for them. A secondary aim was to provide recommendations on the type of components that would best minimize notching and loss of range of motion (ROM). The study included 12 fresh frozen shoulder specimens; each had a computed tomography (CT) image of the entire scapula and humerus in order to acquire topological information of the bones before RSA implantation. Cyclic tests were run postimplantation with 3 shoulders in each modalities. To quantify bone loss due to impingement, 3-dimensional anatomical models of the scapula were reconstructed from the CT scans and compared to their intact states. We found 8 bony impingements in 7 specimens: 2 at the lateral acromion, 1 at the inferior acromion, 4 scapular notching, and 1 with the glenoid resulting to wear at the 3:00 to 6:00 clock-face position. Impingements occurred in all kinds of tested motions, except for the internal/external rotation at 90° of abduction. The 3 specimens tested in abduction/adduction presented bone loss on the acromion side only. Scapular notching was noted in flexion/extension and in internal/external rotation at 0° of abduction. The humeral polyethylene liner was worn in 2 specimens—1 at the 6:00 to 8:00 clock-face position during internal/external rotation at 0° of abduction and 1 at the 4:00 clock-face position during flexion/extension. The present study revealed that 2 types of impingement interactions coexist and correspond to a frank abutment or lead to a scapular notching (friction-type impingement). Scapular notching seems to be caused by more movements or combination of movements than previously considered, and in particular by movements of flexion/extension and internal/external rotation with the arm at the side. Polyethylene cups with a notch between 3 and 9 o’clock and lower neck-shaft angle (145° or 135°) may play an important role in postoperative ROM limiting scapular notching. PMID:26402829
Choi, Chang Hyuk; Kim, Sung Guk; Lee, Jae Jun; Kwack, Byung Hoon
2017-03-01
In a previous biomechanical study, eccentric glenospheres with more inferior position of the center of rotation were shown to improve range of motion and reduce the incidence of scapular notching after reverse total shoulder arthroplasty (RSA). The purpose of this study was to compare the clinical and radiological results of RSA using an eccentric glenosphere to those using a concentric glenosphere and to determine the usefulness of the eccentric glenosphere. From 2009 to 2015, we performed a retrospective review of 20 consecutive patients who underwent RSA using a deltopectoral approach. Nine patients underwent RSA using a concentric glenosphere (group A) while 11 had an eccentric glenosphere (group B). The average follow-up period was 13.9 months (range, 12 to 18 months). All glenoid components were placed with 15° of inferior tilt. Clinical results were assessed using the visual analog pain scale score (VAS), the American Shoulder and Elbow Surgeon (ASES) score, the Korean shoulder scoring system (KSS), and the Constant score. On radiological evaluation, prosthesisscapular neck angle (PSNA), peg-glenoid rim distance (PGRD), scapular neck-inferior glenoshere rim distance (inferior glenoshpere overhang), acromion-greater tuberosity (AT) distance, glenoid-greater tuberosity (GT) distance, and severity of notching according to the Nerot-Sirveaux classification were assessed. The clinical results improved significantly in both groups, but there was no statistically significant difference between the two groups. A significant intergroup difference was observed with regard to PGRD (24.8 ± 1.6 mm for group A vs. 22.2 ± 1.9 mm for group B; p = 0.002) and inferior glenosphere overhang (2.0 ± 1.7 mm for group A vs. 5.8 ± 1.6 mm for group B; p = 0.000). Seven of 9 patients in group A developed notching compared with 2 of 11 patients in group B ( p = 0.022). The other radiological parameters such as inferior tilt and AT and GT distances were not significantly different between two groups. Complications such as loosening and scapular fractures did not occur. The eccentric glenosphere in RSA was more effective in reducing the rate of notching than the concentric glenosphere although clinical outcomes were not significantly different in the short-term follow-up.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Young K., E-mail: Young.Lee@rmh.nhs.uk; McVey, Gerard P.; South, Chris P.
2013-07-01
Dose distributions for prostate radiotherapy are difficult to predict in patients with bilateral hip prostheses in situ, due to image distortions and difficulty in dose calculation. The feasibility of delivering curative doses to prostate using intensity-modulated radiotherapy (IMRT) in patients with bilateral hip prostheses was evaluated. Planning target volumes for prostate only (PTV1) and pelvic nodes (PTV2) were generated from data on 5 patients. PTV1 and PTV2 dose prescriptions were 70 Gy and 60 Gy, respectively, in 35 fractions, and an additional nodal boost of 65 Gy was added for 1 plan. Rectum, bladder, and bowel were also delineated. Beammore » angles and segments were chosen to best avoid entering through the prostheses. Dose-volume data were assessed with respect to clinical objectives. The plans achieved the required prescription doses to the PTVs. Five-field IMRT plans were adequate for patients with relatively small prostheses (head volumes<60 cm{sup 3}) but 7-field plans were required for patients with larger prostheses. Bowel and bladder doses were clinically acceptable for all patients. Rectal doses were deemed clinically acceptable, although the V{sub 50} {sub Gy} objective was not met for 4/5 patients. We describe an IMRT solution for patients with bilateral hip prostheses of varying size and shape, requiring either localized or whole pelvic radiotherapy for prostate cancer.« less
Clinical outcome and complications of thoracic and pelvic limb stump and socket prostheses.
Phillips, Andrew; Kulendra, Elvin; Bishop, Edith; Monk, Michelle; Parsons, Kevin; House, Arthur
2017-07-20
To describe the use, quality of life, compliance, complications, and outcome of animals fitted with stump socket prostheses. Medical records of dogs fitted with a stump socket prosthesis were reviewed. Functional outcome, quality of life and complications were retrospectively assessed from an owner questionnaire. Thirteen stump socket prostheses (12 dogs) were fitted for a variety of reasons including trauma, congenital abnormalities, and neoplasia. Eight dogs had a good outcome overall and four a poor outcome. Quality of life (QOL) remained good or excellent in 10/12 dogs. Nine complications were seen in 7/12 dogs, most were manageable; surgical wound complications (n = 2) and pressures sores (n = 4) were the most frequently encountered. One dog suffered multiple complications. Thoracic and pelvic limb stump socket prostheses had a similar complication rate, however all animals with a poor outcome had a thoracic limb stump socket prosthesis; two were small breed dogs (under 10 kg) and two had bilateral thoracic limb abnormalities. Stump socket prostheses are feasible and versatile in animals. In correctly selected cases, good to excellent outcomes are possible. However, complications are frequent but often manageable. Further investigations are required into the risk factors for poor outcomes and prospective studies are required to assess changes in biomechanics, function, and QOL before and after fitting of a stump socket prosthesis. Until further evidence is available, careful consideration should be given before fitting bilateral thoracic limb stump socket prostheses or thoracic limb stump socket prostheses to small breed dogs.
In vivo testing of porous Ti-25Nb alloy serving as a femoral stem prosthesis in a rabbit model
Weng, Xiaojun; Yang, Hailin; Xu, Jian; Li, Xiaosheng; Liao, Qiande; Wang, Jing
2016-01-01
The aim of the present study was to observe the performance of Ti-25Nb alloys with various porosities as femoral stem prostheses in a rabbit model, thus providing basic experimental evidence for the development of porous prostheses. The porous Ti-25Nb alloy prostheses were designed according to the morphology of the medullary cavity. These prostheses were placed into the femoral medullary cavities in 36 New Zealand white rabbits. Postoperative X-ray films, scanning electron microscopy (SEM) of the implant interface, energy-dispersive spectroscopy (EDS) analysis of the implant surface, pulling-out test and general observations were conducted. The specimens showed good biocompatibility; there was no obvious bone absorption in porous Ti-25Nb specimens with different porosities at different time points observed using X-ray films. Under SEM examination, calcium deposits were observed inside the pores and in the interface between bone and prostheses. The EDS analysis demonstrated that calcium deposits were present on the surface of the prostheses at the eight-week point postoperatively. The pulling-out test showed good bonding strength between bone and implant; after pulling out, the surface and inside the pores of the prostheses all presented bone mass. Porous Ti-25Nb alloy implants presents good biocompatibility as well as providing a biological fixation between the bone and implant. A porosity of 70% is more advantageous to the newborn bone ingrowth, combined with achieving a more solid bone-implant interface. PMID:27602063
Kennon, Justin C; Lu, Caroline; McGee-Lawrence, Meghan E; Crosby, Lynn A
2017-06-01
Reverse total shoulder arthroplasty (RTSA) is a viable treatment option for rotator cuff tear arthropathy but carries a complication risk of scapular fracture. We hypothesized that using screws above the central glenoid axis for metaglene fixation creates a stress riser contributing to increased scapula fracture incidence. Clinical type III scapular fracture incidence was determined with screw placement correlation: superior screw vs. screws placed exclusively below the glenoid midpoint. Cadaveric RTSA biomechanical modeling was employed to analyze scapular fractures. We reviewed 318 single-surgeon single-implant RTSAs with screw correlation to identify type III scapular fractures. Seventeen cadaveric scapula specimens were matched for bone mineral density, metaglenes implanted, and fixation with 2 screw configurations: inferior screws alone (group 1 INF ) vs. inferior screws with one additional superior screw (group 2 SUP ). Biomechanical load to failure was analyzed. Of 206 patients, 9 (4.4%) from the superior screw group experienced scapula fractures (type III); 0 fractures (0/112; 0%) were identified in the inferior screw group. Biomechanically, superior screw constructs (group 2 SUP ) demonstrated significantly (P < .05) lower load to failure (1077 N vs. 1970 N) compared with constructs with no superior screws (group 1 INF ). There was no significant age or bone mineral density discrepancy. Clinical scapular fracture incidence significantly decreased (P < .05) for patients with no screws placed above the central cage compared with patients with superior metaglene screws. Biomechanical modeling demonstrates significant construct compromise when screws are used above the central cage, fracturing at nearly half the ultimate load of the inferior screw constructs. We recommend use of inferior screws, all positioned below the central glenoid axis, unless necessary to stabilize the metaglene construct. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Roche, Christopher P; Stroud, Nicholas J; Flurin, Pierre-Henri; Wright, Thomas W; Zuckerman, Joseph D; DiPaola, Matthew J
2014-09-01
In this glenoid loosening study, we compared the fixation strength of multiple generic reverse shoulder glenoid baseplates that differed only in backside geometry and shape and size to optimize design from a fixation perspective. The fixation strength of 4 generic baseplates was quantified in a low-density polyurethane substrate to isolate the contribution of baseplate profile and size (25 mm circular vs 25 × 34 mm oval) and backside geometry (flat back vs curved back) on fixation using 2 center-of-rotation glenospheres (0 mm and 10 mm lateral). The cyclic test simulated 55° of abduction as a 750 N load was continuously applied to induce a variable shear and compressive load. Before and after cyclic loading, baseplate displacement was measured in the directions of the applied static shear and compressive loads. Each generic baseplate was cyclically tested 7 times with each offset glenosphere for a total of 56 samples. Circular baseplates were associated with significantly more shear displacement in both the superior-inferior (SI) and anterior-posterior (AP) directions after cyclic loading than oval baseplates. No such significant differences in fixation were observed between flat-back and curved-back baseplates. Circular baseplates were also associated with significantly more SI and AP shear displacement with 10 mm glenospheres than with 0 mm glenospheres. No significant difference in SI or AP motion was observed with oval baseplates between 0 mm and 10 mm glenospheres. Our results suggest that baseplate shape and size affects fixation strength more than backside geometry. The 25 × 34 mm oval baseplates showed better fixation characteristics than their 25 mm circular counterparts; no discernible difference in fixation was observed between flat-back and curved-back baseplates. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Craig, Edward V; Galatz, Leesa M; Sperling, John W
2014-01-01
Rotator cuff pathology and tearing remains a common cause of shoulder pain and disability. Although little controversy and disagreement exists regarding the treatment of small to moderate size tears in good quality tissue without retraction, there is difficulty in agreeing on the ideal treatment of the largest tears, particularly because those tears may be accompanied by widely variable levels of pain and function. Clinical decision making is made more difficult because of the variable presentations observed in patients with a documented full-thickness rotator cuff tear: some have good function and no pain, some have good function and pain, some have poor function and no pain, and some have both poor function and pain. The role of biologics as an adjunct in treating most rotator cuff tears remains unclear, with ongoing exploration of the roles of stem cells, growth factors, and platelet-rich plasma. In patients with unreconstructable tears with marked weakness in external rotation but good elevation, a latissimus transfer may restore rotation. Patches may play a role in partial repairs while serving as both a lattice for healing and a biomechanical anchoring point for sutures. In patients with massive tears and arthritis and in many who have rotator cuff insufficiency, pseudoparalysis, or anterosuperior escape without arthritis, reverse shoulder arthroplasty has led to improvements in pain and strength and revolutionized the treatment of rotator cuff tears.
Rotational biomechanics of the elite golf swing: benchmarks for amateurs.
Meister, David W; Ladd, Amy L; Butler, Erin E; Zhao, Betty; Rogers, Andrew P; Ray, Conrad J; Rose, Jessica
2011-08-01
The purpose of this study was to determine biomechanical factors that may influence golf swing power generation. Three-dimensional kinematics and kinetics were examined in 10 professional and 5 amateur male golfers. Upper-torso rotation, pelvic rotation, X-factor (relative hip-shoulder rotation), O-factor (pelvic obliquity), S-factor (shoulder obliquity), and normalized free moment were assessed in relation to clubhead speed at impact (CSI). Among professional golfers, results revealed that peak free moment per kilogram, peak X-factor, and peak S-factor were highly consistent, with coefficients of variation of 6.8%, 7.4%, and 8.4%, respectively. Downswing was initiated by reversal of pelvic rotation, followed by reversal of upper-torso rotation. Peak X-factor preceded peak free moment in all swings for all golfers, and occurred during initial downswing. Peak free moment per kilogram, X-factor at impact, peak X-factor, and peak upper-torso rotation were highly correlated to CSI (median correlation coefficients of 0.943, 0.943, 0.900, and 0.900, respectively). Benchmark curves revealed kinematic and kinetic temporal and spatial differences of amateurs compared with professional golfers. For amateurs, the number of factors that fell outside 1-2 standard deviations of professional means increased with handicap. This study identified biomechanical factors highly correlated to golf swing power generation and may provide a basis for strategic training and injury prevention.
Kim, Seok-Gyu; Son, Mee-Kyoung
2015-01-01
PURPOSE The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and noncemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening. PMID:26140172
Determination of a safe INR for joint injections in patients taking warfarin.
Bashir, M A; Ray, R; Sarda, P; Li, S; Corbett, S
2015-11-01
With an increase in life expectancy in 'developed' countries, the number of elderly patients receiving joint injections for arthritis is increasing. There are legitimate concerns about an increased risk of thromboembolism if anticoagulation is stopped or reversed for such an injection. Despite being a common dilemma, the literature on this issue is scarce. We undertook 2,084 joint injections of the knee and shoulder in 1,714 patients between August 2008 and December 2013. Within this cohort, we noted 41 patients who were taking warfarin and followed them immediately after joint injection in the clinic or radiology department, looking carefully for complications. Then, we sought clinical follow-up, correspondence, and imaging evidence for 4 weeks, looking for complications from these joint injections. We recorded International Normalised Ratio (INR) values before injection. No complications were associated with the procedure after any joint injection. The radiologists who undertook ultrasound-guided injections to shoulders re-scanned the joints looking for haemarthroses: they found none. A similar outcome was noted clinically after injections in the outpatient setting. With a mean INR of 2.77 (range, 1.7-5.5) and a maximum INR within this group of 5.5, joint injections to the shoulder and knee can be undertaken safely in primary or secondary care settings despite the patient taking warfarin.
Computerized design of speech prostheses.
Leonard, R J
1991-08-01
The use of computerized techniques to assist in the design of palatal and/or glossal prostheses is described. Patients with oropharyngeal resection and associated speech impairment are candidates for such prostheses. Procedures discussed allow for the design of some features of the prosthesis, such as shape, location, and tests of its effect on certain speech parameters, prior to actual fabrication. Advantages and current limitations of the techniques are also discussed.
ERIC Educational Resources Information Center
Livingston, Patricia M.; White, Victoria; Roberts, Susan; Pritchard, Emma; Gibbs, Anne; Hill, David J.
2003-01-01
For many women, the only alternative to breast reconstruction following a mastectomy is to use external prostheses, which need replacing regularly at a cost of up to $395 per prosthesis. Commonwealth and state governments across Australia have responded to this need by providing subsidies to assist in the purchase of breast prostheses. However,…
Cranioplasty prosthesis manufacturing based on reverse engineering technology
Chrzan, Robert; Urbanik, Andrzej; Karbowski, Krzysztof; Moskała, Marek; Polak, Jarosław; Pyrich, Marek
2012-01-01
Summary Background Most patients with large focal skull bone loss after craniectomy are referred for cranioplasty. Reverse engineering is a technology which creates a computer-aided design (CAD) model of a real structure. Rapid prototyping is a technology which produces physical objects from virtual CAD models. The aim of this study was to assess the clinical usefulness of these technologies in cranioplasty prosthesis manufacturing. Material/Methods CT was performed on 19 patients with focal skull bone loss after craniectomy, using a dedicated protocol. A material model of skull deficit was produced using computer numerical control (CNC) milling, and individually pre-operatively adjusted polypropylene-polyester prosthesis was prepared. In a control group of 20 patients a prosthesis was manually adjusted to each patient by a neurosurgeon during surgery, without using CT-based reverse engineering/rapid prototyping. In each case, the prosthesis was implanted into the patient. The mean operating times in both groups were compared. Results In the group of patients with reverse engineering/rapid prototyping-based cranioplasty, the mean operating time was shorter (120.3 min) compared to that in the control group (136.5 min). The neurosurgeons found the new technology particularly useful in more complicated bone deficits with different curvatures in various planes. Conclusions Reverse engineering and rapid prototyping may reduce the time needed for cranioplasty neurosurgery and improve the prosthesis fitting. Such technologies may utilize data obtained by commonly used spiral CT scanners. The manufacturing of individually adjusted prostheses should be commonly used in patients planned for cranioplasty with synthetic material. PMID:22207125
Shu, Beatrice; Johnston, Tyler; Lindsey, Derek P; McAdams, Timothy R
2012-02-01
Enhancing anterior-posterior (AP) stability in acromioclavicular (AC) reconstruction may be advantageous. To compare the initial stability of AC reconstructions with and without augmentation by either (1) a novel "reverse" coracoacromial (CA) ligament transfer or (2) an intramedullary AC tendon graft. Reverse CA transfer will improve AP stability compared with isolated coracoclavicular (CC) reconstruction. Controlled laboratory study. Six matched pairs of cadaveric shoulders underwent distal clavicle resection and CC reconstruction. Displacement (mm) was measured during cyclic loading along AP (±25 N) and superior-inferior (SI; 10-N compression, 70-N tension) axes. Pairs were randomized to receive each augmentation and the same loading protocol applied. Reverse CA transfer (3.71 ± 1.3 mm, standard error of the mean [SEM]; P = .03) and intramedullary graft (3.41 ± 1.1 mm; P = .03) decreased AP translation compared with CC reconstruction alone. The SI displacement did not differ. Equivalence tests suggest no difference between augmentations in AP or SI restraint. Addition of either reverse CA transfer or intramedullary graft demonstrates improved AP restraint and provides similar SI stability compared with isolated CC reconstruction. Reverse CA ligament transfer may be a reasonable alternative to a free tendon graft to augment AP restraint in AC reconstruction.
Prostheses for stapes surgery.
Slattery, W H; House, J W
1995-04-01
A variety of different implants are available today for use by the otologic surgeon. All prostheses are well tolerated, and the risks of complication as a result of their implantation are comparable. The most commonly used prostheses are the wire-Teflon piston and the stainless steel bucket handle. Although the otologic surgeon has a wide variety of prostheses to choose from, most have a preference for one particular type. Results of hearing improvement following a successful stapedectomy is more a function of the surgeon's experience than of the type of prosthesis used. As James L. Sheehy, MD, so often says, "if a technique is working well for you, don't change for change's sake" (personal communication, 1994).
Cuff, Derek J; Pupello, Derek R; Santoni, Brandon G
2016-11-01
A subset of patients with massive irreparable rotator cuff tears present with retained overhead elevation and pain as their primary complaint. Our aim was to evaluate the outcomes of partial arthroscopic rotator cuff repair with biceps tenotomy and to report the failure rate of this procedure for patients with >5 years of follow-up. Thirty-four patients underwent partial rotator cuff repair and biceps tenotomy for treatment of a massive rotator cuff tear. Patients had preoperative active forward elevation >120° and no radiographic evidence of glenohumeral arthritis. Patients were followed up clinically and radiographically, and 28 patients had a minimum of 5 years of follow-up. Failure was defined as an American Shoulder and Elbow Surgeons score of <70, loss of active elevation >90°, or revision to reverse shoulder arthroplasty during the study period. Patients demonstrated improvements in average preoperative to postoperative American Shoulder and Elbow Surgeons scores (46.6 to 79.3 [P < .001]) and Simple Shoulder Test scores (5.7 to 9.1 [P < .001]) along with decrease in visual analog scale for pain scores (6.9 to 1.9 [P < .001]). No significant change in forward elevation (168° to 154° [P = .07]), external rotation (38° to 39° [P = 1.0]), or internal rotation (84% to 80% [P = 1.0]) was identified; 36% of patients had progression of the Hamada stage. The failure rate was 29%; 75% of patients were satisfied with their index procedure. Partial rotator cuff repair and biceps tenotomy for patients with massive irreparable rotator cuff tears with retained overhead elevation and pain as the primary complaint produced reasonable outcomes at midterm follow-up of at least 5 years. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Speech assessment of patients using three types of indwelling tracheo-oesophageal voice prostheses.
Heaton, J M; Sanderson, D; Dunsmore, I R; Parker, A J
1996-04-01
A multidisciplinary prospective study compared speech acceptability between three types of indwelling tracheo-oesophageal voice prostheses. Twenty male laryngectomees took part over five years, using 42 prostheses. Speech was assessed on a discrete scale by trained and untrained personnel. The majority scored in the mid-range for each assessor. The kappa coefficient was used to test similarity between assessors, and for all pairings agreement was significant (p < 0.05). The speech and language therapist tended to give higher scores and the patient lower. A relationship was found between patients' ages categorized by decade and the surgeon's score alone. This relationship held for Groningen high resistance and Provox prostheses individually too (p < 0.05). The untrained assessed similarly to the professionals--humans are all voice listeners. The analysis suggests surgeons find tracheo-oesophageal speech in older patients better than in younger ones; or make more allowances for the elderly. There was a trend for Provox prostheses to produce the best scores.
Optical coherence tomography and confocal microscopy investigations of dental prostheses
NASA Astrophysics Data System (ADS)
Negrutiu, Meda L.; Sinescu, Cosmin; Hughes, Michael; Bradu, Adrian; Rominu, Mihai; Todea, Carmen; Dobre, George; Podoleanu, Adrian
2008-09-01
Dental prostheses are very complex systems, heterogenous in structure, made up from various materials, with different physical properties. An essential question mark is on the physical, chemical and mechanical compatibility between these materials. They have to satisfy high stress requirements as well as esthetic challenges. The masticatory stress may induce fractures of the prostheses, which may be triggered by initial materials defects or by alterations of the technological process. The failures of dental prostheses lead to functional, esthetic and phonetic disturbances which finally render the prosthetic treatment inefficient. The purpose of this study is to evaluate the capability of en-face optical coherence tomography as a possible non-invasive high resolution method in supplying the necessary information on the material defects of dental prostheses and microleakage at prosthetic interfaces. C-scan and B-scan OCT images as well as confocal images are acquired from a large range of samples. Gaps between the dental interfaces and material defects are clearly exposed. We conclude that OCT can successfully be used as a noninvasive analysis method.
Using speech for mode selection in control of multifunctional myoelectric prostheses.
Fang, Peng; Wei, Zheng; Geng, Yanjuan; Yao, Fuan; Li, Guanglin
2013-01-01
Electromyogram (EMG) recorded from residual muscles of limbs is considered as suitable control information for motorized prostheses. However, in case of high-level amputations, the residual muscles are usually limited, which may not provide enough EMG for flexible control of myoelectric prostheses with multiple degrees of freedom of movements. Here, we proposed a control strategy, where the speech signals were used as additional information and combined with the EMG signals to realize more flexible control of multifunctional prostheses. By replacing the traditional "sequential mode-switching (joint-switching)", the speech signals were used to select a mode (joint) of the prosthetic arm, and then the EMG signals were applied to determine a motion class involved in the selected joint and to execute the motion. Preliminary results from three able-bodied subjects and one transhumeral amputee demonstrated the proposed strategy could achieve a high mode-selection rate and enhance the operation efficiency, suggesting the strategy may improve the control performance of commercial myoelectric prostheses.
Quantitative assessment of four men using above-elbow prosthetic control.
Popat, R A; Krebs, D E; Mansfield, J; Russell, D; Clancy, E; Gill-Body, K M; Hogan, N
1993-07-01
We studied the relationship between kinematically unconstrained activities of daily living (ADL) tasks and a kinematically constrained task in above-elbow (AE) amputee subjects using myoelectrically controlled prostheses. Four men, 24 to 49 years old, with unilateral AE amputation wore a prosthesis interfaced to a programmable controller to emulate two different elbow control schemes, conventional velocity and a new "natural" controller. Subjects were timed during three ADL tasks--cutting meat, donning socks, and rolling dough--with both controllers. The prosthesis emulator was then connected to a crank device with a handle, and the subjects turned the crank from bottom to top positions in a vertical plane using each controller. Synergistic shoulder-elbow joint coordination required for crank turning was quantified as the maximum slope of the change in elbow torque versus the change in crank-angle. Performance between the two controllers differed significantly for the crank test but not for ADL tasks. One subject did not complete all crank turning tests. Positive canonical correlation of 0.77 was found between time and crank domain measures. We conclude that biomechanical assessments should be integrated with time-based clinical tests to comprehensively evaluate performance of AE amputee subjects with a myoelectric device.
Linking of total elbow prosthesis during surgery; a biomechanical analysis.
De Vos, Maarten J; Wagener, Marc L; Hendriks, Jan C M; Eygendaal, Denise; Verdonschot, Nico
2013-09-01
Presently, 2 types of elbow prostheses are used: unlinked and linked. The Latitude total elbow prosthesis allows the surgeon to decide during the implantation whether the prosthesis is placed unlinked or linked, and whether the native radial head is retained, resected, or replaced. The purpose of this study is to assess and to compare the varus and valgus laxity of the unlinked and linked version of the latitude total elbow prosthesis with: (1) the native radial head preserved, (2) the native radial head excised, and (3) the native radial head replaced by a radial head component. Biomechanical testing was performed on 14 fresh-frozen upper limb specimens. Linking the prosthesis predominantly influences the valgus laxity of the elbow. Linking the Latitude total elbow prosthesis results in increased valgus stability. In the linked version of the total elbow prosthesis, the radial head only plays a small part in both valgus and varus stability. An unlinked situation is not advised in absence of a native radial head or in case of inability to replace the radial head. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Bragaru, Mihai; Dekker, Rienk; Geertzen, Jan H B
2012-09-01
Sport prostheses are used by both upper- and lower-limb amputees while participating in sports and other physical activities. Although the number of these devices has increased over the past decade, no overview of the peer reviewed literature describing them has been published previously. Such an overview will allow specialists to choose appropriate prostheses based on available scientific evidence rather than on personal experience or preference. To provide an overview of the sport prostheses as they are described by the papers published in peer reviewed literature. Literature review. Four electronic databases were searched using free text and Medical Subject Headings (MESH) terms. Papers were included if they concerned a prosthesis or a prosthetic adaptation used in sports. Papers were excluded if they did not originate from peer reviewed sources, if they concerned prostheses for body parts other than the upper or lower limbs, if they concerned amputations distal to the wrist or ankle, or if they were written in a language other than English. Twenty-four papers were included in this study. The vast majority contained descriptive data and consisted of expert opinions and technical notes. Data concerning the energy efficiency, technical characteristics and special mechanical properties of prostheses or prosthetic adaptations for sports, other than running, are scarce.
Differences in myoelectric and body-powered upper-limb prostheses: Systematic literature review.
Carey, Stephanie L; Lura, Derek J; Highsmith, M Jason
2015-01-01
The choice of a myoelectric or body-powered upper-limb prosthesis can be determined using factors including control, function, feedback, cosmesis, and rejection. Although body-powered and myoelectric control strategies offer unique functions, many prosthesis users must choose one. A systematic review was conducted to determine differences between myoelectric and body-powered prostheses to inform evidence-based clinical practice regarding prescription of these devices and training of users. A search of 9 databases identified 462 unique publications. Ultimately, 31 of them were included and 11 empirical evidence statements were developed. Conflicting evidence has been found in terms of the relative functional performance of body-powered and myoelectric prostheses. Body-powered prostheses have been shown to have advantages in durability, training time, frequency of adjustment, maintenance, and feedback; however, they could still benefit from improvements of control. Myoelectric prostheses have been shown to improve cosmesis and phantom-limb pain and are more accepted for light=intensity work. Currently, evidence is insufficient to conclude that either system provides a significant general advantage. Prosthetic selection should be based on a patient's individual needs and include personal preferences, prosthetic experience, and functional needs. This work demonstrates that there is a lack of empirical evidence regarding functional differences in upper-limb prostheses.
Robotic cadaver testing of a new total ankle prosthesis model (German Ankle System).
Richter, Martinus; Zech, Stefan; Westphal, Ralf; Klimesch, Yvone; Gosling, Thomas
2007-12-01
An investigation was carried out into possible increased forces, torques, and altered motions during load-bearing ankle motion after implantation of two different total ankle prostheses. We hypothesized that the parameters investigated would not differ in relation to the two implants compared. We included two different ankle prostheses (Hintegra, Newdeal, Vienne, France; German Ankle System, R-Innovation, Coburg, Germany). The prostheses were implanted in seven paired cadaver specimens. The specimens were mounted on an industrial robot that enables complex motion under predefined conditions (RX 90, Stäubli, Bayreuth, Germany). The robot detected the load-bearing (30 kg) motion of the 100(th) cycle of the specimens without prostheses as the baseline for the later testing, and mimicked that exact motion during 100 cycles after the prostheses were implanted. The resulting forces, torques, and bone motions were recorded and the differences between the prostheses compared. The Hintegra and German Ankle System, significantly increased the forces and torques in relation to the specimen without a prosthesis with one exception (one-sample-t-test, each p < or = 0.01; exception, parameter lateral force measured with the German Ankle System, p = 0.34). The force, torque, and motion differences between the specimens before and after implantation of the prostheses were lower with the German Ankle System than with the Hintegra (unpaired t-test, each p < or = 0.05). The German Ankle System prosthesis had less of an effect on resulting forces and torques during partial weightbearing passive ankle motion than the Hintegra prosthesis. This might improve function and minimize loosening during the clinical use.
Fritsch, Michael H; Gutt, Jason J
2005-03-01
A 3-T magnetic resonance field may cause motion or displacement of middle ear implants not seen in studies with 1.5-T magnets. Previous publications have described the safety limitations of some otologic implants in 1.5-T magnetic resonance fields. Several company-wide recalls of implants were issued. No studies to date have been reported for otologic implants within a 3-T magnetic resonance field, nor have there been comparisons with a 1.5-T field strength. Eighteen commonly used middle ear implants and prostheses were selected. In Part 1, the prostheses were placed in Petri dishes and exposed to a 3-T magnetic resonance field. In Part 2, the particular prostheses that showed movement in Part 1 were placed into their intended use positions within temporal bone laboratory specimens and exposed to a 3-T field. Both parts were repeated in a 1.5-T field. In Part 1, three prostheses moved dramatically from their start positions when exposed to the 3-T magnetic resonance field. In Part 2, the three particular prostheses that showed movement in Part 1 showed no gross displacement or movement from their start positions within the temporal bone laboratory specimens. No implants moved in the 1.5-T field in either Part 1 or Part 2. Certain stapes prostheses move dramatically in Petri dishes in 3-T fields. When placed into temporal bone laboratory specimens, the same prostheses show no signs of movement from the surgical site in a 3-T field, and it appears that the surgical position holds the implants firmly in place. Results of published 1.5-T field studies should not be used directly for safety recommendations in a 3-T magnetic resonance. Heat, voltage induction, and vibration during exposure to the magnetic resonance fields should be considered as additional possible safety issues. Preference should be given to platinum and titanium implants in manufacturing processes and surgical selection.
Hall, R M; Unsworth, A
1997-08-01
Although the reduction of frictional torques was the driving force behind the design of the Charnley prosthesis, later concerns about wear and subsequent loosening of this and other hip replacements have dominated debate within the bioengineering community. To stimulate discussion on the role of friction in loosening, a review of the frictional characteristics of different prostheses was undertaken. The use of simple laboratory screening-type machines in the frictional assessment of different material combinations is discussed together with experiments performed on single axis simulators using both conventional and experimental prostheses. In particular, recent developments in the use of soft layer components are highlighted. Further, the possible link between excessively high frictional torques and loosening is discussed in the light of current results obtained from explanted prostheses.
The use of prostheses in skeletally immature patients.
Abudu, Adesegun; Grimer, Robert; Tillman, Roger; Carter, Simon
2006-01-01
Prosthetic reconstruction in the skeletally immature patient is challenging because of the necessity to cope with expected disruption of limb growth after resection of one or more major growth plates and the high demands placed on implants by young patients. Although prosthetic reconstruction in children is fraught with many problems, it is usually possible to obtain a good functional limb at skeletal maturity. Extendable prostheses are readily acceptable to patients and their parents. The availability of noninvasive extendable prostheses is expected to lead to fewer complications, fewer surgical interventions, and even improved function. This article reviews the indication, evolution, and clinical and functional results of extendable endoprostheses, drawing from experience in the last 30 years of using such prostheses in children.
Time-dependent changes after latissimus dorsi transfer: tenodesis or tendon transfer?
Erşen, Ali; Ozben, Hakan; Demirhan, Mehmet; Atalar, Ata Can; Kapıcıoğlu, Mehmet
2014-12-01
Transfer of the latissimus dorsi tendon to the posterosuperior part of the rotator cuff is an option in active patients with massive rotator cuff tears to restore shoulder elevation and external rotation. However, it is unknown whether this treatment prevents progression of cuff tear arthropathy. The purpose of this study was to determine whether the observed improvement in shoulder function in the early postoperative period with latissimus dorsi tendon transfer for irreparable rotator cuff tears will be permanent or will deteriorate in the midterm period (at 1-5 years after surgery). During a 6-year period, we performed 11 latissimus dorsi tendon transfers in 11 patients for patients with massive, irreparable, chronic tears of the posterosuperior part of the rotator cuff (defined as > 5 cm supraspinatus and infraspinatus tendon tears with Goutallier Grade 3 to 4 fatty infiltration on MRI), for patients who were younger than 65 years of age, and had high functional demands and intact subscapularis function. No patients were lost to followup; minimum followup was 12 months (median, 33 months; range, 12-62 months). The mean patient age was 55 years (median, 53 years; range, 47-65 years). Shoulder forward elevation, external rotation, and Constant-Murley and American Shoulder and Elbow Surgeons scores were assessed. Pain was assessed by a 0- to 10-point visual analog scale. Acromiohumeral distance and cuff tear arthropathy (staged according to the Hamada classification) were evaluated on radiographs. Shoulder forward elevation, external rotation, Constant-Murley scores, and American Shoulder and Elbow Surgeons scores improved at 6 months. However, although shoulder motion values and Constant-Murley scores remained unchanged between the 6-month and latest evaluations, American Shoulder and Elbow Surgeons scores decreased in this period (median, 71; range, 33-88 versus median, 68; range, 33-85; p = 0.009). Visual analog scale scores improved between the preoperative and 6-month evaluations but then worsened (representing worse pain) between the 6-month and latest evaluations (median, 2; range, 0-5 versus median, 2; range, 1-6; p = 0.034), but scores at latest followup were still lower than preoperative values (median, 7; range, 4-8; p = 0.003). Although acromiohumeral distance values were increased at 6 months (median, 8 mm; range, 6-10 mm; p = 0.023), the values at latest followup (median, 8 mm; range, 5-10 mm) were no different from the preoperative ones (mean, 7 mm; range, 6-9 mm; p > 0.05). According to Hamada classification, all patients were Grade 1 both pre- and postoperatively, except one who was Grade 3 at latest followup. The latissimus dorsi tendon transfer may improve shoulder function in irreparable massive rotator cuff tears. However, because the tenodesis effect loses its strength with time, progression of the arthropathy should be expected over time. Nevertheless, latissimus dorsi tendon transfer may help to delay the need for reverse shoulder arthroplasty for these patients. Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
Drago, Carl
2016-08-01
The purpose of this report was to retrospectively evaluate implant and immediate full-arch prosthesis survival rates over a 24-month period; patients were consecutively treated with immediate occlusal loading. Dental arch, gender, and implant orientation (vertical vs. tilted) were also noted. All Brånemark System implants (Nobel Active) and interim, all-acrylic resin prostheses placed in patients following an All-on-Four™ protocol, in a single private practice were assessed by retrospective patient chart review. The amount of space provided surgically for implant restorative components and prostheses was determined from measurements of the vertical heights of the interim prostheses in the right/left anterior and posterior segments. These measurements were made in the laboratory. Interim prosthetic repairs (type, frequency, length of time from insertion) were analyzed by type, arch, gender, and implant orientation. Implant survival and insertion torque values were also measured. Inclusion criteria consisted of all Brånemark System implants placed with the All-on-Four protocol from September 1, 2011, until August 31, 2013. Specific dietary instructions were given for the first 7 days immediately postoperatively and for the weeks prior to insertion of the definitive prostheses. One hundred twenty-nine patients, comprising 191 arches (766 implants) from September 1, 2011, until August 31, 2013, were included in the study. One patient experienced implant failure yielding an overall implant survival rate (SR) of 99.5% (762 of 766). Four hundred twenty-six of 430 maxillary implants and 336 of 336 mandibular implants survived for SRs of 99.1% and 100%, respectively. Regarding implant orientation, 415 of 417 tilted implants (SR 99.5%) and 343 of 345 (CSR 95.6%) vertical implants were noted to be clinically stable. Interim, all-acrylic resin prostheses were in place for a mean of 199.2 days; mandibular prostheses were in place for an average of 195.4 days; maxillary prostheses were in place for an average of 202.0 days. Thirty four of the 191 interim prostheses (17.8%) warranted at least one repair during the treatment period. The average overall implant insertion torque value was 60.74 Ncm; mandibular torque values averaged 63.08 Ncm; maxillary torque values averaged 59.00 Ncm. The results from this study suggest that dental arch, gender, and implant orientation for implants placed and immediately restored with interim, all-acrylic resin, full-arch prostheses per the All-on-Four protocol did not have significant statistical or clinical effects on prosthetic complications of the interim prostheses or implant survival. Only one of the 129 patients experienced implant failures, indicating that the All-on-Four treatment protocol used in this study is a viable alternative to other protocols for rehabilitating edentulous patients. © 2015 by the American College of Prosthodontists.
Al Refai, Roa'a; Saker, Samah
2018-01-01
The expected length of service and reasons for fixed dental prostheses (FDPs) replacement are a frequent inquiry by patients while the answers were mainly based on studies reports that was conducted outside the middle east region. This clinical and radiographic survey was constructed to assess and survey clinically and radiographically the reasons of replacement of metal-ceramic fixed dental prostheses, amongst patients reporting at dental school in Taibah University. Between January and May 2016, 151 patients were recruited for this study. Interview (include questions pertained to the length of service of the prosthesis, the nature of complaint as told by patient in her own words), clinical examination, intra-oral photographs, and periapical radiographs, were done by the researchers. The parameters assessed were secondary caries, open margins, loss of retention, failure of endodontic treatment of the abutment and periodontal diseases. A total number of 249 failed fixed dental prostheses were evaluated. Of which 180 (39.7%) were single crowns, 159 (35.0%) were retainers and 117 (25.8%) were pontics in 69 fixed partial denture. The most common reason for replacement of fixed restorations was periodontal diseases affecting 92.8% of all types' restorations, followed by defective margin in 90.4% of examined restoration, poor aesthetic in 88% of restorations, while periapical involvement was found in 85.5% of fixed dental prosthesis. The survival rates of fixed prostheses were not predictable, and no association was found between number of years in service and the number of restorations. The most common reasons for replacing single unit fixed dental prostheses are periodontal diseases and periapical involvement, while defective margins and poor aesthetic mainly associated with multi-unit fixed dental prostheses. Key words: Failure, Fixed dental prosthesis, Survival, Replacement.
Henderson, Eric R; Pepper, Andrew M; Letson, G Douglas
2012-04-01
Growing prostheses accommodate skeletally immature patients with bone tumors undergoing limb-preserving surgery. Early devices required surgical procedures for lengthening; recent devices lengthen without surgery. Expenses for newer expandable devices that lengthen without surgery are more than for their predecessors but overall reimbursement amounts are not known. We sought to determine reimbursement amounts associated with lengthening of growing prostheses requiring surgical and nonsurgical lengthening. We retrospectively reviewed 17 patients with growing prostheses requiring surgical expansion and eight patients with prostheses capable of nonsurgical expansion. Insurance documents were reviewed to determine the reimbursement for implantation, lengthening, and complications. Growth data were obtained from the literature. Mean reimbursement amounts of surgical and nonsurgical lengthenings were $9950 and $272, respectively. Estimated reimbursements associated with implantation of a growing prosthesis varied depending on age, sex, and location. The largest difference was found for 4-year-old boys with distal femoral replacement where reimbursement for expansion to maturity for surgical and nonsurgical lengthening prostheses would be $379,000 and $208,000, respectively. For children requiring more than one surgical expansion, net reimbursements were lower when a noninvasive lengthening device was used. Annual per-prosthesis maintenance reimbursements to address complications for surgical and nonsurgical lengthening prostheses were $3386 and $1856, respectively. This study showed that reimbursements for lengthening of growing endoprostheses capable of nonsurgical expansion may be less expensive in younger patients, particularly male patients undergoing distal femur replacement, than endoprostheses requiring surgical lengthening. Longer outcomes studies are required to see if reimbursements for complications differ between devices. Level III, economic and decision analysis. See the Guidelines for Authors for a complete description of levels of evidence.
Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per
2012-11-01
To describe patterns of prosthesis wear and perceived prosthetic usefulness in adult acquired upper-limb amputees (ULAs). To describe prosthetic skills in activities of daily life (ADL) and the actual use of prostheses in the performance of ADL tasks. To estimate the influence of prosthetic skills on actual prosthesis use and the influence of background factors on prosthetic skills and actual prosthesis use. Cross-sectional study analysing population-based questionnaire data (n = 224) and data from interviews and clinical testing in a referred/convenience sample of prosthesis-wearing ULAs (n = 50). Effects were analysed using linear regression. 80.8% wore prostheses. 90.3% reported their most worn prosthesis as useful. Prosthetic usefulness profiles varied with prosthetic type. Despite demonstrating good prosthetic skills, the amputees reported actual prosthesis use in only about half of the ADL tasks performed in everyday life. In unilateral amputees, increased actual use was associated with sufficient prosthetic training and with the use of myoelectric vs cosmetic prostheses, regardless of amputation level. Prosthetic skills did not affect actual prosthesis use. No background factors showed significant effect on prosthetic skills. Most major ULAs wear prostheses. Individualised prosthetic training and fitting of myoelectric rather than passive prostheses may increase actual prosthesis use in ADL.
Guzmán-Venegas, Rodrigo A; Palma, Felipe H; Biotti P, Jorge L; de la Rosa, Francisco J Berral
2018-06-01
To compare the frequency or spectral components between different regions of the superficial masseter in young natural dentate and total edentulous older adults rehabilitated with removable prostheses and fixed-implant support. A secondary objective was to compare these components between the three groups. 21 young natural dentate and 28 edentulous (14 with removable prostheses and 14 with fixed-implant support) were assessed. High-density surface electromyography (sEMG) was recorded in four portions of the superficial masseter during submaximal isometric bites. Spectral components were obtained through a spectral analysis of the sEMG signals. An analysis of mixed models was used to compare the spectral components. In all groups, the spectral components of the anterior portion were lower than in the posterior region (p < 0.05). Both edentulous groups showed lower spectral components and median frequency slope than the natural dentate group (p < 0.05). The removable prostheses group showed the greatest differences with natural dentate group. There were significant differences in the spectral components recorded in the different regions of the superficial masseter. The lower spectral components and fatigability of older adults rehabilitated with prostheses could be a cause of a greater loss of type II fibers, especially in the removable prostheses group. Copyright © 2018 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Çatlı, Serap, E-mail: serapcatli@hotmail.com; Tanır, Güneş
2013-10-01
The present study aimed to investigate the effects of titanium, titanium alloy, and stainless steel hip prostheses on dose distribution based on the Monte Carlo simulation method, as well as the accuracy of the Eclipse treatment planning system (TPS) at 6 and 18 MV photon energies. In the present study the pencil beam convolution (PBC) method implemented in the Eclipse TPS was compared to the Monte Carlo method and ionization chamber measurements. The present findings show that if high-Z material is used in prosthesis, large dose changes can occur due to scattering. The variance in dose observed in the presentmore » study was dependent on material type, density, and atomic number, as well as photon energy; as photon energy increased back scattering decreased. The dose perturbation effect of hip prostheses was significant and could not be predicted accurately by the PBC method for hip prostheses. The findings show that for accurate dose calculation the Monte Carlo-based TPS should be used in patients with hip prostheses.« less
21 CFR 888.6 - Degree of constraint.
Code of Federal Regulations, 2013 CFR
2013-04-01
... ORTHOPEDIC DEVICES General Provisions § 888.6 Degree of constraint. Certain joint prostheses provide more... affecting the safety and effectiveness of orthopedic prostheses. FDA is defining the following standard...
21 CFR 888.6 - Degree of constraint.
Code of Federal Regulations, 2011 CFR
2011-04-01
... ORTHOPEDIC DEVICES General Provisions § 888.6 Degree of constraint. Certain joint prostheses provide more... affecting the safety and effectiveness of orthopedic prostheses. FDA is defining the following standard...
21 CFR 888.6 - Degree of constraint.
Code of Federal Regulations, 2014 CFR
2014-04-01
... ORTHOPEDIC DEVICES General Provisions § 888.6 Degree of constraint. Certain joint prostheses provide more... affecting the safety and effectiveness of orthopedic prostheses. FDA is defining the following standard...
21 CFR 888.6 - Degree of constraint.
Code of Federal Regulations, 2012 CFR
2012-04-01
... ORTHOPEDIC DEVICES General Provisions § 888.6 Degree of constraint. Certain joint prostheses provide more... affecting the safety and effectiveness of orthopedic prostheses. FDA is defining the following standard...
Forman, R; Beck, W; Barnard, C N
1978-01-01
The actuarial survival and thromboembolic rates for the three types of cloth-covered Starr-Edwards mitral prostheses, models 6300, 6310/6320, and 6400 followed 6, 5, and 2 years, respectively, were not significantly different throughout the years they were followed. The combined cumulative survival and thromboembolic proportion at 5 years for these prostheses were 71 and 66 per cent, respectively. The thromboembolic rates were not different in the following two groups: (a) 238 patients receiving anticoagulants, and (b) 52 patients who had discontinued or who were not receiving anticoagulants. Four patients thrombosed their mitral prostheses. Another 8 per cent had class 3 symptoms after operation, which were attributed to myopathic or restrictive left ventricular dysfunction or other valvular disease. PMID:656234
[Design and optimization of wireless power and data transmission for visual prosthesis].
Lei, Xuping; Wu, Kaijie; Zhao, Lei; Chai, Xinyu
2013-11-01
Boosting spatial resolution of visual prostheses is an effective method to improve implant subjects' visual perception. However, power consumption of visual implants greatly rises with the increasing number of implanted electrodes. In respond to this trend, visual prostheses need to develop high-efficiency wireless power transmission and high-speed data transmission. This paper presents a review of current research progress on wireless power and data transmission for visual prostheses, analyzes relative principles and requirement, and introduces design methods of power and data transmission.
Progress in the clinical development and utilization of vision prostheses: an update
Brandli, Alice; Luu, Chi D; Guymer, Robyn H; Ayton, Lauren N
2016-01-01
Vision prostheses, or “bionic eyes”, are implantable medical bionic devices with the potential to restore rudimentary sight to people with profound vision loss or blindness. In the past two decades, this field has rapidly progressed, and there are now two commercially available retinal prostheses in the US and Europe, and a number of next-generation devices in development. This review provides an update on the development of these devices and a discussion on the future directions for the field. PMID:28539798
[Endoprostheses in geriatric traumatology].
Buecking, B; Eschbach, D; Bliemel, C; Knobe, M; Aigner, R; Ruchholtz, S
2017-01-01
Geriatric traumatology is increasing in importance due to the demographic transition. In cases of fractures close to large joints it is questionable whether primary joint replacement is advantageous compared to joint-preserving internal fixation. The aim of this study was to describe the importance of prosthetic joint replacement in the treatment of geriatric patients suffering from frequent periarticular fractures in comparison to osteosynthetic joint reconstruction and conservative methods. A selective search of the literature was carried out to identify studies and recommendations concerned with primary arthroplasty of fractures in the region of the various joints (hip, shoulder, elbow and knee). The importance of primary arthroplasty in geriatric traumatology differs greatly between the various joints. Implantation of a prosthesis has now become the gold standard for displaced fractures of the femoral neck. In addition, reverse shoulder arthroplasty has become an established alternative option to osteosynthesis in the treatment of complex proximal humeral fractures. Due to a lack of large studies definitive recommendations cannot yet be given for fractures around the elbow and the knee. Nowadays, joint replacement for these fractures is recommended only if reconstruction of the joint surface is not possible. The importance of primary joint replacement for geriatric fractures will probably increase in the future. Further studies with larger patient numbers must be conducted to achieve more confidence in decision making between joint replacement and internal fixation especially for shoulder, elbow and knee joints.
Mizuno, N; Nonaka, S; Ozaki, R; Yoshida, M; Yoneda, M; Walch, G
2017-12-01
In 2014, reverse total shoulder arthroplasty was approved in Japan. We were concerned that the base plate might be incompatible with Japanese who were generally smaller than Westerners. Therefore, we investigated the dimensions and morphology of the normal Japanese glenoid and compared with the normal French glenoid. One hundred Japanese shoulders without glenoid lesions (50 men and 50 women) were investigated and compared with 100 French shoulders (50 men and 50 women). Computed tomography was performed with 3-dimensional image reconstruction and images were analyzed using Glenosys software. Glenoid parameters (width, height, retroversion and inclination) were compared between Japanese and French subjects. In Japanese subjects, the mean glenoid width was 25.5mm, height was 33.3mm, retroversion was 2.3° and inclination was 11.6° superiorly. In French subjects, the mean glenoid width was 26.7mm, height was 35.4mm, retroversion was 6.0° and inclination was 10.4° superiorly. Glenoid width and height were significantly smaller in Japanese subjects than French subjects (P=0.001 and P<0.001), while retroversion was significantly greater in French subjects (P<0.001). There was no significant difference of inclination. These findings will help surgeons to identify suitable patients for RSA and perform the procedure with appropriate preoperative planning. IV: retrospective or historical series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Localized Cell and Drug Delivery for Auditory Prostheses
Hendricks, Jeffrey L.; Chikar, Jennifer A.; Crumling, Mark A.; Raphael, Yehoash; Martin, David C.
2011-01-01
Localized cell and drug delivery to the cochlea and central auditory pathway can improve the safety and performance of implanted auditory prostheses (APs). While generally successful, these devices have a number of limitations and adverse effects including limited tonal and dynamic ranges, channel interactions, unwanted stimulation of non-auditory nerves, immune rejection, and infections including meningitis. Many of these limitations are associated with the tissue reactions to implanted auditory prosthetic devices and the gradual degeneration of the auditory system following deafness. Strategies to reduce the insertion trauma, degeneration of target neurons, fibrous and bony tissue encapsulation, and immune activation can improve the viability of tissue required for AP function as well as improve the resolution of stimulation for reduced channel interaction and improved place-pitch and level discrimination. Many pharmaceutical compounds have been identified that promote the viability of auditory tissue and prevent inflammation and infection. Cell delivery and gene therapy have provided promising results for treating hearing loss and reversing degeneration. Currently, many clinical and experimental methods can produce extremely localized and sustained drug delivery to address AP limitations. These methods provide better control over drug concentrations while eliminating the adverse effects of systemic delivery. Many of these drug delivery techniques can be integrated into modern auditory prosthetic devices to optimize the tissue response to the implanted device and reduce the risk of infection or rejection. Together, these methods and pharmaceutical agents can be used to optimize the tissue-device interface for improved AP safety and effectiveness. PMID:18573323
Pacheco Usmayo, A; Torregrosa Andrés, A; Flores Méndez, J; Luján Marco, S; Rogel Bertó, R
To describe the types of penile prostheses and their components, to review the appropriate magnetic resonance imaging (MRI) acquisition protocol, and to describe the normal imaging findings and possible complications in patients with inflatable penile implants. Three-piece inflatable penile prostheses are the last link in the treatment chain for erectile dysfunction. They can develop complications, which are classified as non-infectious related to the surgical technique, infectious, or due to mechanical failure of the device. MRI is the most appropriate imaging technique for the postsurgical evaluation of penile prostheses. Images are acquired in three planes using sequences with high spatial resolution, first with the prosthesis at rest and then with the prosthesis activated. Copyright © 2017 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.
Appearance of low signal intensity lines in MRI of silicone breast implants.
Stroman, P W; Rolland, C; Dufour, M; Grondin, P; Guidoin, R G
1996-05-01
Magnetic resonance (MR) images of five explanted mammary prostheses were obtained with a 1.5 T GE Signa system using a conventional spin-echo pulse sequence, in order to investigate the low-intensity curvilinear lines which may be observed in MR images of silicone gel-filled breast implants under pressure from fibrous capsules. MR images showed ellipsoid prostheses, often containing multiple low-intensity curvilinear lines which in some cases presented an appearance very similar to that of the linguine sign. Upon opening the fibrous capsules, however, all of the prostheses were found to be completely intact demonstrating that the appearance of multiple low signal intensity curvilinear lines in MR images of silicone gel-filled prostheses is not necessarily a sign of prosthesis rupture. The MR image features which are specific to the linguine sign must be more precisely defined.
["Bionic" arm prostheses. State of the art in research and development].
Pylatiuk, C; Döderlein, L
2006-11-01
A new generation of arm prostheses is being developed worldwide. These so-called bionic prostheses are intended to offer additional functions, such as sensory feedback, extended range of possible movement, intuitive movement control as far as possible, and a more natural cosmetic appearance. In recent years, prosthetic components with much enhanced performance have been developed for use at various levels of the upper limb. Artificial hands that allow for additional grips are are being tested in clinical settings. Innovative methods of signal acquisition and communication with the patient are being intensively researched. Several patients have been provided with prototypes of new arm prostheses. At the moment, the results are limited by the restricted communication between patient and prosthesis. However, we can expect the options for prosthesis control to be extended in the near future.
NASA Astrophysics Data System (ADS)
Suwandi, Agri; Soemardi, Tresna P.; Kiswanto, Gandjar; Kusumaningsih, Widjajalaksmi; I. Gusti Agung I. G., W.
2018-02-01
Prostheses products must undergo simulation and physical testing, before clinical testing. Finite element method is a preliminary simulation for in vivo test. The method visualizes the magnitude of the compressive force and the critical location of the Total Knee Replacement (TKR) prostheses design. In vitro testing is classified as physical testing for prostheses product. The test is conducted to evaluate the potential failure of the product and the characteristics of the prostheses TKR material. Friction and wear testing are part of the in vivo test. Motion of knee joints, which results in the phenomena of extension and deflection in the femoral and tibia insert, is represented by friction and wear testing. Friction and wear tests aim to obtain an approximate lifetime in normal and extreme load patterns as characterized by the shape of the friction surface area. The lifetime estimation requires friction and wear full-scale testing equipments for TKR prostheses products. These are necessary in obtaining initial data on potential product failures and characterizing of the material based on the ASTM F2724-08 standards. Based on the testing result and statistical analysis data, the average wear rate value per year is 2.19 × 10-3 mg/MC, with a 10 % safety limit of volume and 14,400 cycles times, for 15 hours moving nonstop then the prediction of wear life of the component tibia insert is ± 10 years.
Toniollo, Marcelo Bighetti; Macedo, Ana Paula; Rodrigues, Renata Cristina; Ribeiro, Ricardo Faria; de Mattos, Maria G
The aim of this study was to compare the biomechanical performance of splinted or nonsplinted prostheses over short- or regular-length Morse taper implants (5 mm and 11 mm, respectively) in the posterior area of the mandible using finite element analysis. Three-dimensional geometric models of regular implants (Ø 4 × 11 mm) and short implants (Ø 4 × 5 mm) were placed into a simulated model of the left posterior mandible that included the first premolar tooth; all teeth posterior to this tooth had been removed. The four experimental groups were as follows: regular group SP (three regular implants were rehabilitated with splinted prostheses), regular group NSP (three regular implants were rehabilitated with nonsplinted prostheses), short group SP (three short implants were rehabilitated with splinted prostheses), and short group NSP (three short implants were rehabilitated with nonsplinted prostheses). Oblique forces were simulated in molars (365 N) and premolars (200 N). Qualitative and quantitative analyses of the minimum principal stress in bone were performed using ANSYS Workbench software, version 10.0. The use of splinting in the short group reduced the stress to the bone surrounding the implants and tooth. The use of NSP or SP in the regular group resulted in similar stresses. The best indication when there are short implants is to use SP. Use of NSP is feasible only when regular implants are present.
Estimation of appropriate lubricating film thickness in ceramic-on-ceramic hip prostheses
NASA Astrophysics Data System (ADS)
Tauviqirrahman, M.; Muchammad, Bayuseno, A. P.; Ismail, R.; Saputra, E.; Jamari, J.
2016-04-01
Artificial hip prostheses, consisting of femoral head and acetabular cup are widely used and have affected the lives of many people.However, the primary issue associated with the long term performance of hip prostheses is loosening induced by excessive wear during daily activity. Therefore, an effective lubrication is necessary to significantly decrease the wear. To help understand the lubricating performance of such typical hip joint prostheses, in the present paper a hydrodynamic lubrication model based on Reynolds equationwas introduced. The material pairs of ceramic acetabular cup against ceramic femoral head was investegated.The main aim of this study is to investigate of the effect of loading on the formation of lubricating film thickness.The model of a ball-in-socket configuration was considered assuming that the cup was stationary while the ball was to rotate at a steady angular velocityvarying loads.Based on simulation result, it was found that to promote fluid film lubrication and prevent the contacting components leading to wear, the film thickness of lubricant should be determined carefully based on the load applied. This finding may have useful implication in predicting the failure of lubricating synovial fluid film and wear generation in hip prostheses.
Incus replacement prostheses of hydroxylapatite in middle ear reconstruction.
Wehrs, R E
1989-05-01
Hydroxylapatite is a calcium bioceramic that has the same chemical composition as living bone, Ca10 (PO4) 6 (OH) 2. Since 1970 it has been used as a material in reconstructive prostheses and augmentation of lost tissues in various surgical specialties including maxillofacial surgery, plastic surgery, otolaryngology, and orthopedics. For over 20 years the author has used autograft and homograft ossicles in tympanoplasty. These incudi have been modified into prostheses that were utilized in ossicular reconstruction. During this time two principle prostheses have evolved, the notched incus with short and long processes. The short process prosthesis is used with an intact stapes, whereas the notched incus with long process carries the sound pressure directly to the stapedial footplate. These prostheses have been successful in improving and maintaining hearing following tympanoplasty. Unfortunately, however, the use of human tissue has certain limitations: it is not readily accessible and has a limited shelf life. Furthermore, clinicians are wary of using homograft tissue as concern over the AIDS virus spreads. Therefore it was felt prudent to develop a manmade prosthesis that would as nearly as possible match the advantages of living bone. Hydroxylapetite most nearly met those qualifications.
Prototyping for surgical and prosthetic treatment.
Goiato, Marcelo Coelho; Santos, Murillo Rezende; Pesqueira, Aldiéris Alves; Moreno, Amália; dos Santos, Daniela Micheline; Haddad, Marcela Filié
2011-05-01
Techniques of rapid prototyping were introduced in the 1980s in the field of engineering for the fabrication of a solid model based on a computed file. After its introduction in the biomedical field, several applications were raised for the fabrication of models to ease surgical planning and simulation in implantology, neurosurgery, and orthopedics, as well as for the fabrication of maxillofacial prostheses. Hence, the literature has described the evolution of rapid prototyping technique in health care, which allowed easier technique, improved surgical results, and fabrication of maxillofacial prostheses. Accordingly, a literature review on MEDLINE (PubMed) database was conducted using the keywords rapid prototyping, surgical planning, and maxillofacial prostheses and based on articles published from 1981 to 2010. After reading the titles and abstracts of the articles, 50 studies were selected owing to their correlations with the aim of the current study. Several studies show that the prototypes have been used in different dental-medical areas such as maxillofacial and craniofacial surgery; implantology; neurosurgery; orthopedics; scaffolds of ceramic, polymeric, and metallic materials; and fabrication of personalized maxillofacial prostheses. Therefore, prototyping has been an indispensable tool in several studies and helpful for surgical planning and fabrication of prostheses and implants.
Montagnani, Federico; Controzzi, Marco; Cipriani, Christian
2015-01-01
Although significant technological advances have been made in the last forty years, natural and effortless control of upper limb prostheses is still an open issue. Commercially available myoelectric prostheses present limited Degrees of Freedom (DoF) mainly because of the lack of available and reliable independent control signals from the human body. Thus, despite the crucial role that an actuated wrist could play in a transradial prosthesis in terms of avoiding compensatory movements, commercial hand prostheses present only manually adjustable passive wrists or actuated rotators controlled by (unnatural) sequential control strategies. In the present study we investigated the synergies between the humeral orientation with respect to the trunk and the forearm pronation/supination angles during the execution of a wide range of activities of daily living, in healthy subjects. Our results showed consistent postural synergies between the two selected body segments for almost the totality of the activities of daily living under investigation. This is a promising result because these postural synergies could be exploited to automatically control the wrist rotator unit in transradial prostheses improving the fluency and the dexterity of the amputee.
Prostheses and orthoses in the collections of the Auschwitz-Birkenau State Museum.
Przeździak, Bogumił; Lutomirski, Adam; Kulczyk, Maria
2011-01-01
The authors described 424 orthopaedic appliances left by the prisoners of the Nazi Concentration Camp in Oświęcim. A collection of prostheses and orthoses, which is currently a part of the Auschwitz-Birkenau State Museum's exhibition, is extraordinary as it illustrates the fate of innocent, crippled people, who were incarcerated and murdered. Another point of value of the collection is its technical aspect, as it provides a clear picture of construction of prostheses and orthoses at the beginning of the 20th century.
Gøthesen, Øystein; Slover, James; Havelin, Leif; Askildsen, Jan Erik; Malchau, Henrik; Furnes, Ove
2013-07-06
The use of Computer Assisted Surgery (CAS) for knee replacements is intended to improve the alignment of knee prostheses in order to reduce the number of revision operations. Is the cost effectiveness of computer assisted surgery influenced by patient volume and age? By employing a Markov model, we analysed the cost effectiveness of computer assisted surgery versus conventional arthroplasty with respect to implant survival and operation volume in two theoretical Norwegian age cohorts. We obtained mortality and hospital cost data over a 20-year period from Norwegian registers. We presumed that the cost of an intervention would need to be below NOK 500,000 per QALY (Quality Adjusted Life Year) gained, to be considered cost effective. The added cost of computer assisted surgery, provided this has no impact on implant survival, is NOK 1037 and NOK 1414 respectively for 60 and 75-year-olds per quality-adjusted life year at a volume of 25 prostheses per year, and NOK 128 and NOK 175 respectively at a volume of 250 prostheses per year. Sensitivity analyses showed that the 10-year implant survival in cohort 1 needs to rise from 89.8% to 90.6% at 25 prostheses per year, and from 89.8 to 89.9% at 250 prostheses per year for computer assisted surgery to be considered cost effective. In cohort 2, the required improvement is a rise from 95.1% to 95.4% at 25 prostheses per year, and from 95.10% to 95.14% at 250 prostheses per year. The cost of using computer navigation for total knee replacements may be acceptable for 60-year-old as well as 75-year-old patients if the technique increases the implant survival rate just marginally, and the department has a high operation volume. A low volume department might not achieve cost-effectiveness unless computer navigation has a more significant impact on implant survival, thus may defer the investments until such data are available.
Langohr, G Daniel G; Willing, Ryan; Medley, John B; Athwal, George S; Johnson, James A
2016-04-01
Implant design parameters can be changed during reverse shoulder arthroplasty (RSA) to improve range of motion and stability; however, little is known regarding their impact on articular contact mechanics. The purpose of this finite element study was to investigate RSA contact mechanics during abduction for different neck-shaft angles, glenosphere sizes, and polyethylene cup depths. Finite element RSA models with varying neck-shaft angles (155°, 145°, 135°), sizes (38 mm, 42 mm), and cup depths (deep, normal, shallow) were loaded with 400 N at physiological abduction angles. The contact area and maximum contact stress were computed. The contact patch and the location of maximum contact stress were typically located inferomedially in the polyethylene cup. On average for all abduction angles investigated, reducing the neck-shaft angle reduced the contact area by 29% for 155° to 145° and by 59% for 155° to 135° and increased maximum contact stress by 71% for 155° to 145° and by 286% for 155° to 135°. Increasing the glenosphere size increased the contact area by 12% but only decreased maximum contact stress by 2%. Decreasing the cup depth reduced the contact area by 40% and increased maximum contact stress by 81%, whereas increasing the depth produced the opposite effect (+52% and -36%, respectively). The location of the contact patch and maximum contact stress in this study matches the area of damage seen frequently on clinical retrievals. This finding suggests that damage to the inferior cup due to notching may be potentiated by contact stresses. Increasing the glenosphere diameter improved the joint contact area and did not affect maximum contact stress. However, although reducing the neck-shaft angle and cup depth can improve range of motion, our study shows that this also has some negative effects on RSA contact mechanics, particularly when combined. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Vancomycin-induced thrombocytopenia in a 60-year-old man: a case report.
Shah, Ravish A; Musthaq, Adnan; Khardori, Nancy
2009-06-26
Vancomycin, a glycopeptide antibiotic, is used to treat resistant gram-positive infections. There has been a 10- to 20-fold increase in its use over the past 25 years. Although ototoxicity and nephrotoxicity are well known side effects of vancomycin, it can also induce platelet reactive antibodies leading to life-threatening thrombocytopenia. Vancomycin is often clinically overlooked as a cause of thrombocytopenia, especially in a scenario of sepsis or when there is use of heparin. We report a proven case of vancomycin-induced thrombocytopenia and its reversal after discontinuation of vancomycin. A 60-year-old man with a history of hypertension, congestive heart failure and dyslipidemia was admitted for a right shoulder rotator cuff tear. He underwent right-shoulder arthroscopy and rotator cuff repair. About three weeks later, he developed pain, swelling and purulent drainage from his right shoulder. Arthroscopic irrigation and drainage was then performed. Intraoperative fluid revealed the presence of Methicillin susceptible Staphylococcus aureus, vancomycin-sensitive Enterococcus spp. and Serratia marcescens. The patient had no known allergies. After reviewing his antimicrobial susceptibility, he was started on vancomycin 1500 mgs intravenously every 12 hours (to treat both Staphylococcus aureus and Enterococcus spp) and ciprofloxacin 750 mgs by oral induction every 12 hours. The patient's condition improved following antibiotic treatment. He was discharged and allowed to go home on IV vancomycin and oral ciprofloxacin. The patient's platelet count on the day of starting vancomycin therapy was 253 x 10(3)/mm(3). At weeks one, two and three, the counts were 231 x 10(3)/mm(3), 272 x 10(3)/mm and 6 x 103/mm(3), respectively. The patient was admitted for further work-up of the thrombocytopenia. He was later shown to have vancomycin-induced platelet-reactive antibodies, causing significant thrombocytopenia, and then reversal after his vancomycin medication was discontinued. Thrombocytopenia is a potentially life-threatening condition. Vancomycin is often clinically overlooked as a cause of thrombocytopenia, especially in a scenario of sepsis or when there is use of heparin. Simple laboratory testing with drug-dependent antibodies can be helpful in identifying vancomycin as a cause of thrombocytopenia.
Biodeterioration of medical-grade silicone rubber used for voice prostheses: a SEM study.
Neu, T R; Van der Mei, H C; Busscher, H J; Dijk, F; Verkerke, G J
1993-05-01
Silicone voice prostheses used for rehabilitation of speech after total laryngectomy are inserted in an non-sterile habitat. Deposits on explanted Groningen Button voice prostheses revealed a biofilm, due to heavy colonization of the silicone surface by bacteria and yeasts. Furthermore, it was demonstrated by scanning electron microscopy on sectioned explants that the silicone material was deteriorated by filamentous and vegetative yeast cells. The different explants showed a variety of sharp-edged, discrete yeast colonies. The yeasts grew just under the silicone surface and up to 700 microns into the silicone material. Finally, nine different types of defects in the silicone material created by the yeasts are described. This deterioration of the silicone by yeasts seems to be the main reason for the failure and the frequent replacement of the prostheses. The mechanisms of silicone deterioration are still hypothetical.
Trends in Computer-Aided Manufacturing in Prosthodontics: A Review of the Available Streams
Bennamoun, Mohammed
2014-01-01
In prosthodontics, conventional methods of fabrication of oral and facial prostheses have been considered the gold standard for many years. The development of computer-aided manufacturing and the medical application of this industrial technology have provided an alternative way of fabricating oral and facial prostheses. This narrative review aims to evaluate the different streams of computer-aided manufacturing in prosthodontics. To date, there are two streams: the subtractive and the additive approaches. The differences reside in the processing protocols, materials used, and their respective accuracy. In general, there is a tendency for the subtractive method to provide more homogeneous objects with acceptable accuracy that may be more suitable for the production of intraoral prostheses where high occlusal forces are anticipated. Additive manufacturing methods have the ability to produce large workpieces with significant surface variation and competitive accuracy. Such advantages make them ideal for the fabrication of facial prostheses. PMID:24817888
Semenov, V F; Semenov, F V
2013-01-01
The displacement of prostheses of auditory ossicles at the concluding stage of surgery and in the early postoperative period is one of the factors influencing the functional outcome of stapedoplasty. The objective of the present experimental study was to estimate the effectiveness of the use of platelet-rich plasma as an alloy for the laser welding in order to improve fixation of titanium prostheses employed in ossiculoplastic surgery. The results of a series of experiments undertaken to assess the possibility of stabilization of titanium prostheses in the desired position with the help of laser welding indicate that this technique with the use of platelet-rich plasma as an alloy may be a reliable method for the fixation of the reconstructed chain of ossicles in the desired position.
Implant-retained craniofacial prostheses for facial defects
Federspil, Philipp A.
2012-01-01
Craniofacial prostheses, also known as epistheses, are artificial substitutes for facial defects. The breakthrough for rehabilitation of facial defects with implant-retained prostheses came with the development of the modern silicones and bone anchorage. Following the discovery of the osseointegration of titanium in the 1950s, dental implants have been made of titanium in the 1960s. In 1977, the first extraoral titanium implant was inserted in a patient. Later, various solitary extraoral implant systems were developed. Grouped implant systems have also been developed which may be placed more reliably in areas with low bone presentation, as in the nasal and orbital region, or the ideally pneumatised mastoid process. Today, even large facial prostheses may be securely retained. The classical atraumatic surgical technique has remained an unchanged prerequisite for successful implantation of any system. This review outlines the basic principles of osseointegration as well as the main features of extraoral implantology. PMID:22073096
[In situ aortofemoral reconstructions in surgical treatment of infected aortofemoral grafts].
Badretdinov, I A; Pokrovsky, A V
2015-01-01
The article presents a review of literature sources covering possibilities of peiforming in situ aortofemoral reconstructions in surgical treatment of infected aortofemoral grafts. This methodology makes it possible to improve the outcomes of treatment for paraprosthetic infection at the expense of decreasing lethality and morbidity, increasing parameters of patency of grafts and lower limb salvage in the remote postoperative period. Mention should be made that in situ secondary aortofemoral reconstructions are fraught with danger of relapsing paraprosthetic infection, therefore many publications are dedicated to search for prostheses most resistant to infection. The article also presents the results of works devoted to the use of various types of prostheses for in situ secondary aortofemoral reconstructions: prostheses made of polytetrafluoroethylene (PTFE), synthetic grafts saturated with various antibacterial drugs and gelatine, cadaveric allografts, synthetic prostheses treated with silver ions, autovenous conduits based on the femoral and popliteal veins.
Reflections on the present and future of upper limb prostheses.
Farina, Dario; Amsüss, Sebastian
2016-01-01
Despite progress in research and media attention on active upper limb prostheses, presently the most common commercial upper limb prosthetic devices are not fundamentally different from solutions offered almost one century ago. Limited information transfer for both control and sensory-motor integration and challenges in socket technology have been major obstacles. By analysing the present state-of-the-art and academic achievements, we provide our opinion on the future of upper limb prostheses. We believe that surgical procedures for muscle reinnervation and osseointegration will become increasingly clinically relevant; muscle electrical signals will remain the main clinical means for prosthetic control; and chronic electrode implants, first in muscles (control), then in nerves (sensory feedback), will become viable clinical solutions. After decades of suspended clinically relevant progress, it is foreseeable that a new generation of upper limb prostheses will enter the market in the near future based on such advances, thereby offering substantial clinical benefit for patients.
Kobayashi, Toshiki; Orendurff, Michael S; Boone, David A
2013-09-27
The alignment of a lower-limb prosthesis is critical to the successful prosthetic fitting and utilization by the wearer. Loads generated by the socket applied to the residual limb while walking are thought to be different in transfemoral and knee-disarticulation prostheses. The aim of this case series was to compare the socket reaction moments between transfemoral and knee-disarticulation prostheses and to investigate the effect of alignment changes on them. Two amputees, one with a transfemoral prosthesis and another with a knee-disarticulation prosthesis, participated in this study. A Smart Pyramid™ was used to measure socket reaction moments while walking under 9 selected alignment conditions; including nominally aligned, angle malalignments of 6° (flexion, extension, abduction and adduction) and translation malalignments of 15 mm (anterior, posterior, medial and lateral) of the socket relative to the foot. This study found that the pattern of the socket reaction moments was similar between transfemoral and knee-disarticulation prostheses. An extension moment in the sagittal plane and a varus moment in the coronal plane were dominant during stance under the nominally aligned condition. This study also demonstrated that alignment changes might have consistent effects on the socket reaction moments in transfemoral and knee-disarticulation prostheses. Extension and posterior translation of the socket resulted in increases in an extension moment, while abduction and lateral translation of the socket resulted in increases in a varus moment. The socket reaction moments may potentially serve as useful biomechanical parameters to evaluate alignment in transfemoral and knee-disarticulation prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sinescu, C.; Bradu, A.; Duma, V.-F.; Topala, F. I.; Negrutiu, M. L.; Podoleanu, A. G.
2018-02-01
We present a recent investigation regarding the use of optical coherence tomography (OCT) in the monitoring of the calibration loss of sintering ovens for the manufacturing of metal ceramic dental prostheses. Differences in the temperatures of such ovens with regard to their specifications lead to stress and even cracks in the prostheses material, therefore to the failure of the dental treatment. Evaluation methods of the ovens calibration consist nowadays of firing supplemental samples; this is subjective, expensive, and time consuming. Using an in-house developed swept source (SS) OCT system, we have demonstrated that a quantitative assessment of the internal structure of the prostheses, therefore of the temperature settings of the ovens can be made. Using en-face OCT images acquired at similar depths inside the samples, the differences in reflectivity allow for the evaluation of the differences in granulation (i.e., in number and size of ceramic grains) of the prostheses material. Fifty samples, divided in five groups, each sintered at different temperatures (lower, higher, or equal to the prescribed one) have been analyzed. The consequences of the temperature variations with regard to the one prescribed were determined. Rules-of-thumb were extracted to monitor objectively, using only OCT images of currently manufactured samples, the settings of the oven. The method proposed allows for avoiding producing prostheses with defects. While such rules-of-thumb achieve a qualitative assessment, an insight in our on-going work on the quantitative assessment of such losses of calibration on dental ovens using OCT is also made.
Lemos, Cleidiel Aparecido Araujo; Verri, Fellippo Ramos; Santiago, Joel Ferreira; Almeida, Daniel Augusto de Faria; Batista, Victor Eduardo de Souza; Noritomi, Pedro Yoshito; Pellizzer, Duardo Piza
2018-01-01
The purpose of this study was to evaluate different retention systems (cement- or screw-retained) and crown designs (non-splinted or splinted) of fixed implant-supported restorations, in terms of stress distributions in implants/components and bone tissue, by 3-dimensional (3D) finite element analysis. Four 3D models were simulated with the InVesalius, Rhinoceros 3D, and SolidWorks programs. Models were made of type III bone from the posterior maxillary area. Models included three 4.0-mm-diameter Morse taper (MT) implants with different lengths, which supported metal-ceramic crowns. Models were processed by the Femap and NeiNastran programs, using an axial force of 400 N and oblique force of 200 N. Results were visualized as the von Mises stress and maximum principal stress (σmax). Under axial loading, there was no difference in the distribution of stress in implants/components between retention systems and splinted crowns; however, in oblique loading, cemented prostheses showed better stress distribution than screwed prostheses, whereas splinted crowns tended to reduce stress in the implant of the first molar. In the bone tissue cemented prostheses showed better stress distribution in bone tissue than screwed prostheses under axial and oblique loading. The splinted design only had an effect in the screwed prosthesis, with no influence in the cemented prosthesis. Cemented prostheses on MT implants showed more favorable stress distributions in implants/components and bone tissue. Splinting was favorable for stress distribution only for screwed prostheses under oblique loading.
Essayed, Walid I; Unadkat, Prashin; Hosny, Ahmed; Frisken, Sarah; Rassi, Marcio S; Mukundan, Srinivasan; Weaver, James C; Al-Mefty, Ossama; Golby, Alexandra J; Dunn, Ian F
2018-03-02
OBJECTIVE Endoscopic endonasal approaches are increasingly performed for the surgical treatment of multiple skull base pathologies. Preventing postoperative CSF leaks remains a major challenge, particularly in extended approaches. In this study, the authors assessed the potential use of modern multimaterial 3D printing and neuronavigation to help model these extended defects and develop specifically tailored prostheses for reconstructive purposes. METHODS Extended endoscopic endonasal skull base approaches were performed on 3 human cadaveric heads. Preprocedure and intraprocedure CT scans were completed and were used to segment and design extended and tailored skull base models. Multimaterial models with different core/edge interfaces were 3D printed for implantation trials. A novel application of the intraoperative landmark acquisition method was used to transfer the navigation, helping to tailor the extended models. RESULTS Prostheses were created based on preoperative and intraoperative CT scans. The navigation transfer offered sufficiently accurate data to tailor the preprinted extended skull base defect prostheses. Successful implantation of the skull base prostheses was achieved in all specimens. The progressive flexibility gradient of the models' edges offered the best compromise for easy intranasal maneuverability, anchoring, and structural stability. Prostheses printed based on intraprocedure CT scans were accurate in shape but slightly undersized. CONCLUSIONS Preoperative 3D printing of patient-specific skull base models is achievable for extended endoscopic endonasal surgery. The careful spatial modeling and the use of a flexibility gradient in the design helped achieve the most stable reconstruction. Neuronavigation can help tailor preprinted prostheses.
Paré and prosthetics: the early history of artificial limbs.
Thurston, Alan J
2007-12-01
There is evidence for the use of prostheses from the times of the ancient Egyptians. Prostheses were developed for function, cosmetic appearance and a psycho-spiritual sense of wholeness. Amputation was often feared more than death in some cultures. It was believed that it not only affected the amputee on earth, but also in the afterlife. The ablated limbs were buried and then disinterred and reburied at the time of the amputee's death so the amputee could be whole for eternal life. One of the earliest examples comes from the 18th dynasty of ancient Egypt in the reign of Amenhotep II in the fifteenth century bc. A mummy in the Cairo Museum has clearly had the great toe of the right foot amputated and replaced with a prosthesis manufactured from leather and wood. The first true rehabilitation aids that could be recognized as prostheses were made during the civilizations of Greece and Rome. During the Dark Ages prostheses for battle and hiding deformity were heavy, crude devices made of available materials - wood, metal and leather. Such were the materials available to Ambroise Paré who invented both upper-limb and lower-limb prostheses. His 'Le Petit Lorrain', a mechanical hand operated by catches and springs, was worn by a French Army captain in battle. Subsequent refinements in medicine, surgery and prosthetic science greatly improved amputation surgery and the function of prostheses. What began as a modified crutch with a wooden or leather cup and progressed through many metamorphoses has now developed into a highly sophisticated prosthetic limb made of space-age materials.
Pre-load on oral implants after screw tightening fixed full prostheses: an in vivo study.
Duyck, J; Van Oosterwyck, H; Vander Sloten, J; De Cooman, M; Puers, R; Naert, I
2001-03-01
The fit of implant supported fixed prostheses is said to be of clinical concern because of the rigid fixation of an oral implant in its surrounding bone. The influence of the torque sequence of the set screws during fixation of implant supported fixed full prostheses on the final pre-load was investigated in vitro. No significant effect of the torque sequence of the set screws on the final pre-load was observed. The main objective of this study was to quantify and qualify the pre-load in vivo on implants supporting a fixed full prosthesis. This was performed when the prostheses were supported by all five or six implants and was repeated when the prostheses were supported by only four and three implants. A total of 13 patients with a fixed full implant supported prosthesis were selected. The existing abutments were changed for strain gauged abutments. After tightening the set screws with a torque of 10 N cm, the pre-load conditions were registered. The average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 323 N (43 N), 346 N (59 N), 307 N (60 N) 21 N cm (3 N cm) and 21 N cm (2 N cm), 23 N cm (5 N cm), respectively. In addition, the pre-load was registered after fixation of a machined gold cylinder, as delivered by the manufacturer, on each of the supporting implants, representing the 'optimal fit' situation. The corresponding average (SEM) axial forces and bending moments in case of five or six, four and three supporting implants were 426 N (36 N), 405 N (40 N), 413 N (46 N) and 8 N cm (1 N cm), 8 N cm (1 N cm), 8 N cm (1 N cm), respectively. The induced axial forces after tightening the prostheses were significantly lower then after tightening the gold cylinder in case of five or six supporting implants (P < 0.02). The induced bending moments after tightening the prostheses were statistically significantly higher (P < 0.0001) then after tightening the gold cylinder in all test conditions (five or six, four or three supporting implants). This study underlines the static load present after screw tightening implant supported fixed full prostheses.
The closing behavior of mechanical aortic heart valve prostheses.
Lu, Po-Chien; Liu, Jia-Shing; Huang, Ren-Hong; Lo, Chi-Wen; Lai, Ho-Cheng; Hwang, Ned H C
2004-01-01
Mechanical artificial heart valves rely on reverse flow to close their leaflets. This mechanism creates regurgitation and water hammer effects that may form cavitations, damage blood cells, and cause thromboembolism. This study analyzes closing mechanisms of monoleaflet (Medtronic Hall 27), bileaflet (Carbo-Medics 27; St. Jude Medical 27; Duromedics 29), and trileaflet valves in a circulatory mock loop, including an aortic root with three sinuses. Downstream flow field velocity was measured via digital particle image velocimetry (DPIV). A high speed camera (PIVCAM 10-30 CCD video camera) tracked leaflet movement at 1000 frames/s. All valves open in 40-50 msec, but monoleaflet and bileaflet valves close in much less time (< 35 msec) than the trileaflet valve (>75 msec). During acceleration phase of systole, the monoleaflet forms a major and minor flow, the bileaflet has three jet flows, and the trileaflet produces a single central flow like physiologic valves. In deceleration phase, the aortic sinus vortices hinder monoleaflet and bileaflet valve closure until reverse flows and high negative transvalvular pressure push the leaflets rapidly for a hard closure. Conversely, the vortices help close the trileaflet valve more softly, probably causing less damage, lessening back flow, and providing a washing effect that may prevent thrombosis formation.
Surface evaluation of orthopedic hip implants marketed in Brazil
NASA Astrophysics Data System (ADS)
Souza, M. M.; Trommer, R. M.; Maru, M. M.; Roesler, C. R. M.; Barros, W. S.; Dutra, M. S.
2016-07-01
One of the factors that contribute to the quality of total hip prostheses is the degree of accuracy in the manufacturing of the joint surfaces. The dimensional control of joint components is important because of its direct influence on the durability and, consequently, in the patients’ life quality. This work presents studies on the form and roughness of orthopedic hip prostheses marketed in Brazil. The results provide data for quality control of the surfaces of the femoral heads and acetabular components of hip prostheses and indicate the need of improvement in the procedures used to this control.
Differential effects of speech prostheses in glossectomized patients.
Leonard, R J; Gillis, R
1990-12-01
Five patients representing different categories of glossal resection were fitted with prostheses specifically designed to improve speech. Speech recordings made for subjects with and without their prostheses were subjected to a variety of analyses. Prosthetic influence on listeners' judgments of severity level/intelligibility, number of consonants in error, and on the acoustic measure F2 range of vowels was evaluated. Findings indicated that all subjects demonstrated improvement on the speech measures. However, the extent of improvement on each measure varied across speakers and resection categories. Implications of the findings for prosthetic speech rehabilitation in this population are discussed.
Fabrication of a new silicone auricular prosthesis without removing the existing metallic framework.
Goveas, Reiyal; Shrestha, Binit; Srithavaj, M L Theerathavaj; Thaworanunta, Sita
2014-12-01
Silicone prostheses require constant repair and refabrication. Auricular prostheses retained with implants have better retention than adhesive-retained prostheses. However, refabrication is complicated if the patient is unwilling to surrender the metallic framework attached to the implants and revert to the use of adhesives. This article describes a technique by which the metal framework of the existing prosthesis need not be removed, thereby improving the patient's quality of life until the new prosthesis is delivered. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Re-operation for aortic and mitral prosthetic dysfunctions.
Kaul, T K; Sastry, M R; Mercer, J L; Meade, J B
1985-01-01
The overall incidence of re-operation and prosthetic valve endocarditis was low in the present series as mechanical prostheses were used predominantly. The prosthetic dysfunctions were less frequent following the primary implantation with Bjork Shiley prostheses, but high operative risk was associated with the clotted Bjork Shiley prostheses. We also had unusual experience of strut fracture and sticking of Bjork Shiley discs in the closed position in both aortic and mitral positions. The early deaths were nil since the use of cardioplegic protection. Intra-operative bleeding due to adhesions can be minimised by using synthetic or heterologous pericardium during the primary operation.
Design features of implants for direct skeletal attachment of limb prostheses
Pitkin, M.
2013-01-01
In direct skeletal attachment (DSA) of limb prostheses, a construct is implanted into an amputee’s residuum bone and protrudes out of the residuum’s skin. This technology represents an alternative to traditional suspension of prostheses via various socket systems, with clear indications when the sockets cannot be properly fitted. Contemporary DSA was invented in the 1990s, and several implant systems have been introduced since then. The current review is intended to compare the design features of implants for DSA whose use in humans or in animal studies has been reported in the literature. PMID:23554122
Complete denture analyzed by optical coherence tomography
NASA Astrophysics Data System (ADS)
Negrutiu, Meda L.; Sinescu, Cosmin; Todea, Carmen; Podoleanu, Adrian G.
2008-02-01
The complete dentures are currently made using different technologies. In order to avoid deficiencies of the prostheses made using the classical technique, several alternative systems and procedures were imagined, directly related to the material used and also to the manufacturing technology. Thus, at the present time, there are several injecting systems and technologies on the market, that use chemoplastic materials, which are heat cured (90-100°C), in dry or wet environment, or cold cured (below 60°C). There are also technologies that plasticize a hard cured material by thermoplastic processing (without any chemical changes) and then inject it into a mold. The purpose of this study was to analyze the existence of possible defects in several dental prostheses using a non invasive method, before their insertion in the mouth. Different dental prostheses, fabricated from various materials were investigated using en-face optical coherence tomography. In order to discover the defects, the scanning was made in three planes, obtaining images at different depths, from 0,01 μm to 2 mm. In several of the investigated prostheses we found defects which may cause their fracture. These defects are totally included in the prostheses material and can not be vizualised with other imagistic methods. In conclusion, en-face OCT is an important investigative tool for the dental practice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brooks, Chris; Cheung, Rex Min; Kudchadker, Rajat J.
2010-07-01
Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning ismore » further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral hip prostheses. The treatment was planned for 75.6 Gy using a 7-field coplanar approach and a noncoplanar arrangement, with all fields avoiding entrance though the prostheses. Our results indicate that, compared with the coplanar plan, the noncoplanar plan delivers the prescribed dose to the target with a slightly better conformality and sparing of rectal tissue versus the coplanar plan.« less
Movement quality of conventional prostheses and the DEKA Arm during everyday tasks
Cowley, Jeffrey; Resnik, Linda; Wilken, Jason; Walters, Lisa Smurr; Gates, Deanna
2017-01-01
Background Conventional prosthetic devices fail to restore the function and characteristic movement quality of the upper limb. The DEKA Arm is a new, advanced prosthesis featuring a compound, powered wrist and multiple grip configurations. Objectives The purpose of this study was to determine if the DEKA Arm improved the movement quality of upper limb prosthesis users compared to conventional prostheses. Study design Case series. Methods Three people with transradial amputation completed tasks of daily life with their conventional prosthesis and with the DEKA Arm. A total of 10 healthy controls completed the same tasks. The trajectory of the wrist joint center was analyzed to determine how different prostheses affected movement duration, speed, smoothness, and curvature compared to patients’ own intact limbs and controls. Results Movement quality decreased with the DEKA Arm for two participants, and increased for the third. Prosthesis users made slower, less smooth, more curved movements with the prosthetic limb compared to the intact limb and controls, particularly when grasping and manipulating objects. Conclusion The effects of one month of training with the DEKA Arm on movement quality varied with participants’ skill and experience with conventional prostheses. Future studies should examine changes in movement quality after long-term use of advanced prostheses. PMID:26932980
Soldering in prosthodontics--an overview, part I.
Byrne, Gerard
2011-04-01
The fit of fixed multiunit dental prostheses (FDP), traditionally termed fixed partial dentures (FPDs), is an ongoing problem. Poorly fitting restorations may hasten mechanical failure, due to abutment caries or screw failure. Soldering and welding play an important role in trying to overcome misfit of fixed multiunit prostheses. The term FPD will be used to denote multiunit fixed dental prostheses in this review. This is the first of a series of articles that review the state of the art and science of soldering and welding in relation to the fit of cemented or screw-retained multiunit prostheses. A comprehensive archive of background information and scientific findings is presented. Texts in dental materials and prosthodontics were reviewed. Scientific data were drawn from the numerous laboratory studies up to and including 2009. The background, theory, terminology, and working principles, along with the applied research, are presented. This first article focuses on soldering principles and dimensional accuracy in soldering. There is some discussion and suggestions for future research and development. Soldering may improve dimensional accuracy or reduce the distortion of multiunit fixed prostheses. Many variables can affect the outcome in soldering technique. Research science has developed some helpful guidelines. Research projects are disconnected and limited in scope. © 2011 by The American College of Prosthodontists.
López-Suárez, Carlos; Gonzalo, Esther; Peláez, Jesús; Rodríguez, Verónica
2015-01-01
Background In recent years there has been an improvement of zirconia ceramic materials to replace posterior missing teeth. To date little in vitro studies has been carried out on the fracture resistance of zirconia veneered posterior fixed dental prostheses. This study investigated the fracture resistance and the failure mode of 3-unit zirconia-based posterior fixed dental prostheses fabricated with two CAD/CAM systems. Material and Methods Twenty posterior fixed dental prostheses were studied. Samples were randomly divided into two groups (n=10 each) according to the zirconia ceramic analyzed: Lava and Procera. Specimens were loaded until fracture under static load. Data were analyzed using Wilcoxon´s rank sum test and Wilcoxon´s signed-rank test (P<0.05). Results Partial fracture of the veneering porcelain occurred in 100% of the samples. Within each group, significant differences were shown between the veneering and the framework fracture resistance (P=0.002). The failure occurred in the connector cervical area in 80% of the cases. Conclusions All fracture load values of the zirconia frameworks could be considered clinically acceptable. The connector area is the weak point of the restorations. Key words:Fixed dental prostheses, zirconium-dioxide, zirconia, fracture resistance, failure mode. PMID:26155341
Evaluation of Osseous Integration of PVD-Silver-Coated Hip Prostheses in a Canine Model
Hauschild, Gregor; Hardes, Jendrik; Gosheger, Georg; Blaske, Franziska; Wehe, Christoph; Karst, Uwe; Höll, Steffen
2015-01-01
Infection associated with biomaterials used for orthopedic prostheses remains a serious complication in orthopedics, especially tumor surgery. Silver-coating of orthopedic (mega)prostheses proved its efficiency in reducing infections but has been limited to surface areas exposed to soft tissues due to concerns of silver inhibiting osseous integration of cementless stems. To close this gap in the bactericidal capacity of silver-coated orthopedic prostheses extension of the silver-coating on surface areas intended for osseous integration seems to be inevitable. Our study reports about a PVD- (physical-vapor-deposition-) silver-coated cementless stem in a canine model for the first time and showed osseous integration of a silver-coated titanium surface in vivo. Radiological, histological, and biomechanical analysis revealed a stable osseous integration of four of nine stems implanted. Silver trace elemental concentrations in serum did not exceed 1.82 parts per billion (ppb) and can be considered as nontoxic. Changes in liver and kidney functions associated with the silver-coating could be excluded by blood chemistry analysis. This was in accordance with very limited metal displacement from coated surfaces observed by laser ablation inductively coupled plasma-mass spectrometry (LA-ICP-MS) 12 months after implantation. In conclusion our results represent a step towards complete bactericidal silver-coating of orthopedic prostheses. PMID:25695057
Shoulder replacement - discharge
Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; Arthroplasty - shoulder - ...
Osterhoff, Georg; O'Hara, Nathan N; D'Cruz, Jennifer; Sprague, Sheila A; Bansback, Nick; Evaniew, Nathan; Slobogean, Gerard P
2017-03-01
There is ongoing debate regarding the optimal surgical treatment of complex proximal humeral fractures in elderly patients. To evaluate the cost-effectiveness of reverse total shoulder arthroplasty (RTSA) compared with hemiarthroplasty (HA) in the management of complex proximal humeral fractures, using a cost-utility analysis. On the basis of data from published literature, a cost-utility analysis was conducted using decision tree and Markov modeling. A single-payer perspective, with a willingness-to-pay (WTP) threshold of Can$50,000 (Canadian dollars), and a lifetime time horizon were used. The incremental cost-effectiveness ratio (ICER) was used as the study's primary outcome measure. In comparison with HA, the incremental cost per quality-adjusted life-year gained for RTSA was Can$13,679. One-way sensitivity analysis revealed the model to be sensitive to the RTSA implant cost and the RTSA procedural cost. The ICER of Can$13,679 is well below the WTP threshold of Can$50,000, and probabilistic sensitivity analysis demonstrated that 92.6% of model simulations favored RTSA. Our economic analysis found that RTSA for the treatment of complex proximal humeral fractures in the elderly is the preferred economic strategy when compared with HA. The ICER of RTSA is well below standard WTP thresholds, and its estimate of cost-effectiveness is similar to other highly successful orthopedic strategies such as total hip arthroplasty for the treatment of hip arthritis. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Chae, S W; Lee, J; Han, S H; Kim, S-Y
2015-06-01
Glenoid component fixation with an inferior tilt has been suggested to decrease scapular notching, but this remains controversial. We aimed here to evaluate the effect of glenoid component inferior tilt in reverse total shoulder arthroplasty (RSA) on micromotion and loss of fixation of the glenoid component by biomechanical testing. Increased inferior reaming of the glenoid for inferiorly tilted implantation of the glenoid component will decrease glenoid bone stock and compromise the fixation of RSA. The micromotions of the glenoid components attached to 14 scapulae from fresh frozen cadavers were measured and compared between neutral and 10° inferior tilts in 0.7- and 1-body weight cyclic loading tests using digital-image analysis. The incidence of bone breakage or loss of fixation was assessed in the 1-body weight fatigue-loading test. Micromotion was higher with a 10° inferior tilt than with a neutral tilt during both the 0.7-body weight (36 ± 11 μm vs. 22 ± 5 μm; P = 0.028) and 1-body weight (44 ± 16 μm vs. 28 ± 9 μm; P = 0.045) cyclic loading. The incidence of bone breakage or loss of fixation was 17% and 60% with a neutral and 10° inferior tilt, respectively. Glenoid component inferior tilt fixation in RSA may reduce primary stability and increase mechanical failure of the glenoid component, thereby reducing longevity of the prosthesis. Accordingly, we recommend careful placement of the glenoid component when an inferior tilt is used. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Spectrum of magnetic resonance imaging findings in clinical glenohumeral instability
Jana, Manisha; Srivastava, Deep Narayan; Sharma, Raju; Gamanagatti, Shivanand; Nag, Hiralal; Mittal, Ravi; Upadhyay, Ashish Dutt
2011-01-01
The glenohumeral joint is the most commonly dislocated joint in the body, and anterior instability is the most common type of shoulder instability. Depending on the etiology and the age of the patient, there may be associated injuries, for example, to the anterior-inferior labro-ligamentous structures (in young individuals with traumatic instability) or to the bony components (commoner in the elderly), which are best visualized using MRI and MR arthrography. Anterior instability is associated with a Bankart lesion and its variants and abnormalities of the anterior band of the inferior glenohumeral ligament (IGHL), whereas posterior instability is associated with reverse Bankart and reverse Hill-Sachs lesions. Cases of multidirectional instability often have no labral pathology on imaging but show specific osseous changes including increased chondrolabral retroversion. This article reviews the relevant anatomy in brief and describes the MRI findings in each type, with the imaging features of the common abnormalities. PMID:21799591
Danino, A; Rocher, F; Blanchet-Bardon, C; Revol, M; Servant, J M
2001-02-01
The efficacy of breast prosthesis texturing in the prevention of capsular contracture has been established for about 20 years. This successful procedure has led to the development and marketing of a number of different models. In the present study, four porous-textured breast prostheses have been examined: the Arion monoblock implant, the CUI (McGahn), the Biocell (Mcgahn), and the Sebbin LS21. Scanning electron microscopic (SEM) investigation of the implant surfaces of the different prostheses was carried out on new samples received from the manufacturers. During a prospective study on eight patients, capsule samples corresponding to the four above-mentioned prostheses were taken to determine whether a secondary intervention was necessary for correction of asymmetry or malpositioning. These samples were analyzed by SEM to investigate whether there could be a correlation between prosthesis texturing and the aspect of the corresponding capsules. Significant ultrastructural differences were found between the various prostheses examined: the results showed that only the CUI and Biocell prostheses presented a mirror image of the capsule texturing, with a correspondence between the depressions on the prosthesis and the contacts on the capsule. This finding seems to be linked to the existence of a critical size for the pores that constitute the implant surface. This observation led to the hypothesis of an adhesive "velcro" effect between the prosthesis and its capsule. Although the latter may not be directly linked to the prevention of capsular contracture it can, however, have a major effect on implant stabilization in cases of primary breast reconstruction and in possible secondary adjustments of asymmetry and malpositioning.
Campos, Camila H; Ribeiro, Giselle R; Rodrigues Garcia, Renata C M
2018-05-01
Alzheimer disease (AD) can affect masticatory function, affecting oral health-related quality of life (OHRQoL). Whether oral rehabilitation with conventional removable prostheses can restore masticatory function and improve OHRQoL in these individuals is unknown. The purpose of this clinical study was to evaluate the influence of oral rehabilitation with removable prostheses on masticatory efficiency and OHRQoL in elders with and without AD. Thirty-two elders with mild AD (n=16, mean age=76.7 ±6.3 years) or without AD (n=16, mean age=75.2 ±4.4 years) were recruited. All participants first underwent masticatory efficiency and OHRQoL evaluations, and 2 months after insertion of new removable prostheses, the variables were reassessed. Masticatory efficiency was determined using the sieving method, and OHRQoL was measured by applying the Geriatric Oral Health Assessment Index (GOHAI). The data from the baseline and after insertion of the new removable prostheses were compared by paired t test. Group differences at each time point were assessed by t test (α=.05). After insertion of the new removable prostheses, masticatory efficiency and OHRQoL improved in both the elders with AD and the control. At baseline, elders with AD had lower masticatory efficiency and higher OHRQoL than controls (P<.05). After removable prosthesis insertion, elders with AD continued to show lower masticatory efficiency values than controls, but their OHRQoL was similar. Oral rehabilitation with new removable prostheses improved the masticatory efficiency and OHRQoL of elders with and without AD, although masticatory efficiency did not reach control levels in elders with AD. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Kon, Kazuhiro; Shiota, Makoto; Sakuyama, Aoi; Ozeki, Maho; Kozuma, Wataru; Kawakami, Sawako; Kasugai, Shohei
2017-02-01
The present study aimed to evaluate the effect of implant prostheses on the occlusal force and area as well as the distribution of occlusal loading in unilateral free-end and intermediate missing cases. Fourteen healthy subjects (7 free-end missing cases in the first and second molars and 7 intermediate missing cases in the first molar region) were included. Six months after the implant prosthesis was placed, an occlusal evaluation was performed with or without the implant superstructure by using Dental Prescale film and an occluder device. In free-end missing cases, the total occlusal force and area, implant-side occlusal force and area, and implant-side occlusal force and area of the residual natural teeth were significantly affected by the implant prostheses. In intermediate missing cases, the implant-side occlusal force of the residual natural teeth was significantly affected by the implant prostheses. In free-end missing cases, the proportions of implant-side occlusal force, non-implant-side occlusal force, and implant-side occlusal force of the residual natural teeth relative to the total occlusal force were significantly affected by the implant prostheses. In the intermediate missing cases, the proportion of the implant-side occlusal force of the residual natural teeth relative to the total occlusal force was significantly affected by the implant prostheses. The proportion of the occlusal area was also significantly affected. In free-end missing cases, implant prostheses significantly increased the occlusal force and area, which resulted in the proper occlusal distribution. In intermediate missing cases, an implant prosthesis may only improve the same-side occlusal loading of the natural teeth.
Characterisation of the responsive properties of two running-specific prosthetic models.
Grobler, Lara; Ferreira, Suzanne; Vanwanseele, Benedicte; Terblanche, Elmarie E
2017-04-01
The need for information regarding running-specific prosthetic properties has previously been voiced. Such information is necessary to assist in athletes' prostheses selection. This study aimed to describe the characteristics of two commercially available running-specific prostheses. The running-specific prostheses were tested (in an experimental setup) without the external interference of athlete performance variations. Four stiffness categories of each running-specific prosthetic model (Xtend ™ and Xtreme ™ ) were tested at seven alignment setups and three drop masses (28, 38 and 48 kg). Results for peak ground reaction force (GRF peak ), contact time ( t c ), flight time ( t f ), reactive strength index (RSI) and maximal compression (Δ L) were determined during controlled dropping of running-specific prostheses onto a force platform with different masses attached to the experimental setup. No statistically significant differences were found between the different setups of the running-specific prostheses. Statistically significant differences were found between the two models for all outcome variables (GRF peak , Xtend > Xtreme; t c , Xtreme > Xtend; t f , Xtreme > Xtend; RSI, Xtend > Xtreme; Δ L, Xtreme > Xtend; p < 0.05). These findings suggest that the Xtreme stores more elastic energy than the Xtend, leading to a greater performance response. The specific responsive features of blades could guide sprint athletes in their choice of running-specific prostheses. Clinical relevance Insights into the running-specific prosthesis (RSP) properties and an understanding of its responsive characteristics have implications for athletes' prosthetic choice. Physiologically and metabolically, a short sprint event (i.e. 100 m) places different demands on the athlete than a long sprint event (i.e. 400 m), and the RSP should match these performance demands.
Luis, Sushil Allen; Blauwet, Lori A; Samardhi, Himabindu; West, Cathy; Mehta, Ramila A; Luis, Chris R; Scalia, Gregory M; Miller, Fletcher A; Burstow, Darryl J
2017-10-15
This study aimed to investigate the utility of transthoracic echocardiographic (TTE) Doppler-derived parameters in detection of mitral prosthetic dysfunction and to define optimal cut-off values for identification of such dysfunction by valve type. In total, 971 TTE studies (647 mechanical prostheses; 324 bioprostheses) were compared with transesophageal echocardiography for evaluation of mitral prosthesis function. Among all prostheses, mitral valve prosthesis (MVP) ratio (ratio of time velocity integral of MVP to that of left ventricular outflow tract; odds ratio [OR] 10.34, 95% confidence interval [95% CI] 6.43 to 16.61, p<0.001), E velocity (OR 3.23, 95% CI 1.61 to 6.47, p<0.001), and mean gradient (OR 1.13, 95% CI 1.02 to 1.25, p=0.02) provided good discrimination of clinically normal and clinically abnormal prostheses. Optimal cut-off values by receiver operating characteristic analysis for differentiating clinically normal and abnormal prostheses varied by prosthesis type. Combining MVP ratio and E velocity improved specificity (92%) and positive predictive value (65%) compared with either parameter alone, with minimal decline in negative predictive value (92%). Pressure halftime (OR 0.99, 95% CI 0.98 to 1.00, p=0.04) did not differentiate between clinically normal and clinically abnormal prostheses but was useful in discriminating obstructed from normal and regurgitant prostheses. In conclusion, cut-off values for TTE-derived Doppler parameters of MVP function were specific to prosthesis type and carried high sensitivity and specificity for identifying prosthetic valve dysfunction. MVP ratio was the best predictor of prosthetic dysfunction and, combined with E velocity, provided a useful parameter for determining likelihood of dysfunction and need for further assessment. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Scher, Steve; Anderson, Kyle; Weber, Nick; Bajorek, Jeff; Rand, Kevin; Bey, Michael J.
2010-01-01
Abstract Context: The overhead throwing motion is complex, and restrictions in range of motion (ROM) at the hip may place additional demands on the shoulder that lead to injury. However, the relationship between hip and shoulder ROM in athletes with and without a history of shoulder injury is unknown. Objective: To (1) determine if differences exist in hip and shoulder ROM between professional baseball players with a history of shoulder injury and those with no history of shoulder injury and (2) assess relationships between hip and shoulder ROM in these players. Design: Cross-sectional study. Patients or Other Participants: Fifty-seven professional baseball players. Main Outcome Measure(s): Outcome measures consisted of hip extension and internal rotation, shoulder internal and external rotation, glenohumeral internal-rotation deficit, and history of shoulder injury. Differences in shoulder and hip ROM were assessed with a 1-way analysis of variance. Associations between hip and shoulder ROM were assessed with linear regression. Results: Nonpitchers with a history of shoulder injury had more external rotation and less internal rotation of the shoulder than nonpitchers with no history of shoulder injury. Glenohumeral internal-rotation deficit was greater in both pitchers and nonpitchers with a history of shoulder injury. The relationship between dominant hip extension and shoulder external rotation was significant for pitchers with a history of shoulder injury and nonpitchers with a history of shoulder injury. Conclusions: Shoulder injury may be associated with specific measures of hip and shoulder ROM, and hip extension and shoulder external rotation may be related in baseball players with a history of shoulder injury. Additional research is necessary to understand the specific mechanisms of shoulder injury in the throwing athlete. PMID:20210623
Occlusal contact of fixed implant prostheses using functional bite impression technique.
Suzuki, Yasunori; Shimpo, Hidemasa; Ohkubo, Chikahiro
2015-02-01
Functional bite impression (FBI) has been described as a definitive impression made under occlusal force after functional generated path (FGP) recording. This study compared the accuracy of occlusal contact of implant-fixed prostheses using the FBI technique and the conventional impression technique. Twelve subjects, each missing a single premolar or molar, were selected for this study. The conditions of the occlusal contacts were identified by the modified transillumination method. The occlusal contact condition was determined by comparing the rate of change in the occlusal contact area of the implant-fixed prostheses and both adjacent teeth before and after occlusal adjustment. The rate of change in the occlusal contact area using the FBI technique was 96%, and the rate using the conventional technique was 54%. The occlusal contact of implant prostheses using the FBI technique revealed better accuracy than that of the conventional technique. Regarding the FBI technique, a precise and functional prosthesis could be produced by completing the maxillomandibular registration, impression, and FGP at the same time.
El Osta, Nada; El Osta, Lana; Moukaddem, Farah; Papazian, Tatiana; Saad, Robert; Hennequin, Martine; Rabbaa Khabbaz, Lydia
2017-04-01
Improvement of nutritional status and perception of oral health are supposed to be different with complete conventional denture or implant-supported fixed or removable prostheses. Since no study has been conducted in Lebanon, the aim of our study was to assess the nutritional status and oral heath related quality of life (OHRQoL) in totally edentulous patients after treatment with complete denture or implant supported-prostheses. This was an observational clinical prospective study. A convenient sample of Lebanese people aged 60 years or more was selected between September 2013 and July 2015 from the Departments of removable and fixed prosthesis at Saint-Joseph University of Beirut. The treatment options included complete denture, implant-supported complete denture and implant-supported fixed prostheses. Nutritional status and OHRQoL were assessed with the Mini-Nutritional Assessment Index (MNA) and the Geriatric Oral Health Assessment Index (GOHAI) respectively at Baseline (first visit before treatment), 2-3 weeks after treatment (t1), 3 months (t2) and 6 months (t3) after treatment. Fifty-one participants (mean age: 69.39 ± 7.164 years) were included. The results have shown an improvement over time in nutritional status and OHRQoL for all treatment groups. However, 2-3 weeks after treatment the number of participants at risk of malnutrition was higher with complete removable denture, intermediate with implant-supported complete denture and lower with implant-supported fixed prostheses (p-value = 0.049). Moreover, the mean GOHAI score was significantly lower over time with complete removable denture compared to implant-supported prostheses (p-value <0.05). Our study has shown an enhancement in the quality of life and the nutritional status for implant supported-prostheses compared to conventional removable dentures. Therefore, it is fundamental that dentists communicate with their patients about implant treatment to understand their expectations, to explain the outcomes and achieve the desired clinical result. Copyright © 2017 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.
Moldovan, Ovidiu; Rudolph, Heike; Luthardt, Ralph G
2016-09-01
Evidence-based therapeutic recommendations for removable dental prostheses are still lacking. The aim of the present study was a systematic review and meta-analysis of the survival rates of removable dentures in the moderately reduced dentition. In 2014, a systematic literature search in established medical databases (MEDLINE, EMBASE, BIOSIS, SciSearch, Cochrane, FIZ Technik Web) and a hand search of relevant dental journals were conducted. The search terms were relevant MeSH terms, free search terms, and combinations of the two. The search included RCTs, prospective and retrospective studies on survival rates of removable dental prostheses in the moderately reduced dentition with at least 15 participants, an observation period of at least 2 years, and a dropout rate of less than 25 %. The selection of relevant publications was carried out at the title, abstract, and full-text level by at least two of the authors involved. The publications included were tabulated and analyzed. Of the original 12,994 matches, 1923 were analyzed by title, 650 by abstract, and 111 according to the full text. The final review included 19 publications, of which 6 were multiple publications. Cast-metal framework dentures exhibited failure rates of between 33 and 50 % after 5 years. One study with a 25-year observation period reported failure rates of 50 %. Better results were obtained with proper pretreatment and a good recall scheme. Bilateral attachment prostheses showed failure rates of between 11 and 30 % after 5 years. Unilateral attachment prostheses showed failure rates of 75 % after 5 years. Double-crown prostheses dentures show failure rates of 0 to 21.7 % after 3 to 6 years. Heterogeneous study designs and data analyses rendered a meta-analysis impossible, so that an evaluation at the highest level of evidence could not be performed. Within the limitations of this study, it would be correct to state that removable dental prostheses, given suitable pretreatment and follow-up regimes, can provide satisfactory solutions. Based on only one paper, they revealed acceptable results even over a very long observation period (25 years).
Sartori, Ivete Aparecida de Mattias; Ribeiro, Ricardo Faria; Francischone, Carlos Eduardo; de Mattos, Maria da Gloria Chiarello
2004-08-01
For implant-supported prostheses, passive fit is critical for the success of rehabilitation, especially when alternative materials are used. The purpose of this study was to compare interfacial fit of implant-supported prostheses cast in titanium to those cast in gold alloy. Five 3-unit fixed partial dentures were fabricated in gold alloy (Degudent U) as 1-piece castings, and 5 others were similarly cast in commercially pure titanium (Grade 1). The interfacial gaps between the prostheses and the abutments were evaluated with an optical microscope, before and after electroerosion. Readings were made with both screws tightened (10 N.cm torque), and with only 1 side tightened, so as to also evaluate the passive fit of the prostheses. Data were compared statistically by 2-way analysis of variance and the post hoc Tukey multiple range test (alpha=.05). Before electroerosion, the interfacial gaps for the 1-piece prostheses were significantly smaller (P<.001) in the gold alloy group when the screws were tightened (Au=12.6 +/- 3.0 microm, compared to Ti=30.1 +/- 6.4 microm). When the side opposite the tightened side was analyzed, there was no significant difference between the gold alloy and titanium groups (Au=69.2 +/- 24.9 microm and Ti=94.2 +/- 39.6 microm). The electroerosion procedure significantly (P<.001) reduced the gaps at the interfaces for both groups under all conditions. Comparison between groups after electroerosion did not present significant differences when the side opposite the tightened side was analyzed, but the gold alloy group showed better fit when the tightened side was analyzed (12.8 +/- 1.4 microm for gold alloy; 29.6 +/- 4.4 microm for titanium) and when both screws were tightened (5.4 +/- 2.3 microm for gold alloy; 16.1 +/- 5.5 microm for titanium). Cast titanium prostheses, despite showing larger interfacial gaps between the prosthesis and abutment than those obtained with gold alloy, had improved fit after being subjected to electroerosion.
Recent advances in bioelectric prostheses
Pasquina, Paul F.; Perry, Briana N.; Miller, Matthew E.; Ling, Geoffrey S.F.; Tsao, Jack W.
2015-01-01
Summary Worldwide prevalence of amputation has created an increasing demand for improved upper and lower extremity prostheses. Current prosthetics are often uncomfortable and difficult to control and provide limited functional restoration. Moreover, the inability to normalize anthropomorphic biomechanics with a prosthesis increases one's risk of developing long-term health risks such as arthritis, skin breakdown, and pain. Recent advances in bionic prosthetic development hold great promise for rehabilitation and improving quality of life with limb loss. This brief review discusses the current state of advanced prostheses, the integration of robotics in the care of individuals with major limb amputation, and some innovative surgical techniques that are being explored for clinical feasibility. PMID:29443190
Processing of hydroxylapatite coatings on titanium alloy bone prostheses
Nastasi, M.A.; Levine, T.E.; Mayer, J.W.; Pizziconi, V.B.
1998-10-06
Processing of hydroxylapatite sol-gel films on titanium alloy bone prostheses. A method utilizing non-line-of-sight ion beam implantation and/or rapid thermal processing to provide improved bonding of layers of hydroxylapatite to titanium alloy substrates while encouraging bone ingrowth into the hydroxylapatite layers located away from the substrate, is described for the fabrication of prostheses. The first layer of hydroxylapatite is mixed into the substrate by the ions or rapidly thermally annealed, while subsequent layers are heat treated or densified using ion implantation to form layers of decreasing density and larger crystallization, with the outermost layers being suitable for bone ingrowth.
Processing of hydroxylapatite coatings on titanium alloy bone prostheses
Nastasi, Michael A.; Levine, Timothy E.; Mayer, James W.; Pizziconi, Vincent B.
1998-01-01
Processing of hydroxylapatite sol-gel films on titanium alloy bone prostheses. A method utilizing non-line-of-sight ion beam implantation and/or rapid thermal processing to provide improved bonding of layers of hydroxylapatite to titanium alloy substrates while encouraging bone ingrowth into the hydroxylapatite layers located away from the substrate, is described for the fabrication of prostheses. The first layer of hydroxylapatite is mixed into the substrate by the ions or rapidly thermally annealed, while subsequent layers are heat treated or densified using ion implantation to form layers of decreasing density and larger crystallization, with the outermost layers being suitable for bone ingrowth.
Tibial rotation kinematics subsequent to knee arthroplasty
Collins, Duane J.; Khatib, Yasser H.; Parker, David A.; Jenkin, Deanne E.; Molnar, Robert B.
2015-01-01
Background The use of computer assisted joint replacement has facilitated precise intraoperative measurement of knee kinematics. The changes in “screw home mechanism” (SHM) resulting from Total Knee Arthroplasty (TKA) with different prostheses and constraints has not yet been accurately described. Methods A pilot study was first completed. Intraoperative kinematic data was collected two groups of 15 patients receiving different prostheses. Results On average, patients lost 5.3° of ER (SD = 6.1°). There was no significant difference between the prostheses or different prosthetic constraints. Conclusions There significant loss of SHM after TKA. Further research is required to understand its impact on patient function. PMID:25829754
28 CFR 43.1 - Administrative determination and assertion of claims.
Code of Federal Regulations, 2010 CFR
2010-07-01
... for the furnishing of hospital, medical, surgical or dental care and treatment (including prostheses... dental care and treatment was or will be furnished for an injury or disease caused under circumstances..., medical, surgical, or dental care and treatment (including prostheses and medical appliances) furnished by...
Koorevaar, Rinco C T; Van't Riet, Esther; Ipskamp, Marcel; Bulstra, Sjoerd K
2017-03-01
Frozen shoulder is a potential complication after shoulder surgery. It is a clinical condition that is often associated with marked disability and can have a profound effect on the patient's quality of life. The incidence, etiology, pathology and prognostic factors of postoperative frozen shoulder after shoulder surgery are not known. The purpose of this explorative study was to determine the incidence of postoperative frozen shoulder after various operative shoulder procedures. A second aim was to identify prognostic factors for postoperative frozen shoulder after shoulder surgery. 505 consecutive patients undergoing elective shoulder surgery were included in this prospective cohort study. Follow-up was 6 months after surgery. A prediction model was developed to identify prognostic factors for postoperative frozen shoulder after shoulder surgery using the TRIPOD guidelines. We nominated five potential predictors: gender, diabetes mellitus, type of physiotherapy, arthroscopic surgery and DASH score. Frozen shoulder was identified in 11% of the patients after shoulder surgery and was more common in females (15%) than in males (8%). Frozen shoulder was encountered after all types of operative procedures. A prediction model based on four variables (diabetes mellitus, specialized shoulder physiotherapy, arthroscopic surgery and DASH score) discriminated reasonably well with an AUC of 0.712. Postoperative frozen shoulder is a serious complication after shoulder surgery, with an incidence of 11%. Four prognostic factors were identified for postoperative frozen shoulder: diabetes mellitus, arthroscopic surgery, specialized shoulder physiotherapy and DASH score. The combination of these four variables provided a prediction rule for postoperative frozen shoulder with reasonable fit. Level II, prospective cohort study.
Ficklscherer, Andreas; Wegener, Bernd; Niethammer, Thomas; Pietschmann, Matthias F; Müller, Peter E; Jansson, Volkmar; Trouillier, Hans-Heinrich
2013-03-01
Recent literature has shown a persistently high rate of aseptic loosening of the tibial component in total ankle prostheses. We analyzed the interface between the tibial bone and tibial component with a thermoelastic stress analysis to demonstrate load transmission onto the distal tibia. In this regard, we used two established ankle prostheses, which were implanted in two human cadaveric and in two third-generation composite tibia bones (Sawbones®, Sweden). Subsequently, the bones were attached to a hydropulser and a sinusoidal load of 700 N was applied. Both prostheses had an inhomogeneous load transmission onto the distal tibia. Instead of distributing load equally to the subarticular bone, forces were focused around the bolting stem, accumulating as stress maxima with forces up to 90 MPa. Furthermore, we were able to demonstrate load transmission into the metaphysis of the bone. As demonstrated in this study, anchoring systems with stems used in all established total ankle prostheses lead to an inhomogeneous load transmission onto the distal tibia, and furthermore, to a distribution of load into the weaker metaphyseal bone. For these reasons, we favor a prosthetic design with minimal bone resection and without any stem or stem-like anchoring system, which facilitates a homogeneous load transmission onto the distal tibia. Thermoelastic stress analysis proved to be a fast and easy-to-perform method to visualize load transmission.
Framework design and pontics of fiber-reinforced composite fixed dental prostheses - An overview.
Perea-Lowery, Leila; Vallittu, Pekka K
2018-05-11
Fiber-reinforced composite (FRC) fixed dental prostheses (FDPs) have shown good performance in clinical applications due to their good mechanical properties and minimally invasive approach. However, typical failure patterns of FRC FDPs are often localized at the pontic site. That reflects the structural considerations at the framework and pontic location that need to be examined when creating these kinds of prostheses. Peer-reviewed articles and other scientific literature were reviewed for providing up-to-date information on how pontics of FRC FDPs can be made. A thorough literature search was done using PubMed and Google Scholar. Two individuals did an assessment of the articles in order to include those related to pontics and framework design of FRC FDPs. The search terms used were "fiber-reinforced dental prosthesis" and "Pontics of fiber-reinforced dental prosthesis". These findings indicate that a cross-sectional fiber design, substructure and thicker pontics made of a variety of materials might reduce failures at the pontic site. The thickness of pontics of FRC FDPs interrelated with the vertical positioning of the FRC framework influences the load-bearing capacities of prostheses of these kinds. The understanding of the factors involved in the fabrication of pontics of FRC FDPs may overcome the drawbacks identified in these prostheses, thus extending their longevity. Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oswald, S.G.; Van Nostrand, D.; Savory, C.G.
1989-08-01
Although few reports address the use of three-phase bone scanning (TPBS) and {sup 111}In-labeled white blood cell (In-WBC) scintigraphy in hip arthroplasty utilizing a porous coated prosthesis, the literature suggests that scintigraphic patterns in the uncomplicated patient may differ from that seen in the cemented prosthesis. In an attempt to determine the scintigraphic natural history, 25 uncomplicated porous coated hip arthroplasties in 21 patients were prospectively studied with serial TPBS and In-WBC at approximately 7 days, and at 3, 6, 12, 18, and 24 mo postoperatively. This report deals with findings related to the prosthetic tip. Only one of 136more » flow studies were abnormal and only two of 136 blood-pool images demonstrated focally increased activity. All 25 prostheses (120 of 143 scans) demonstrated increased uptake on the bone phase images. The area about the tip was divided into three segments; increased uptake at 24 mo was noted in the medial, distal, and lateral segments in 16%, 72%, and 56% of prostheses, respectively. Twenty of 25 prostheses (82 of 142 scans) showed uptake on In-WBC scintigraphy, being noted in 48% of prostheses at 24 mo. We conclude that scintigraphic patterns in the uncomplicated patient with a porous coated prosthesis appear to differ from patterns described in cemented prostheses.« less
Bressan, Eriberto; Lops, Diego; Tomasi, Cristiano; Ricci, Sara; Stocchero, Michele; Carniel, Emanuele Luigi
2014-07-01
Nowadays, dental implantology is a reliable technique for treatment of partially and completely edentulous patients. The achievement of stable dentition is ensured by implant-supported fixed dental prostheses. Morse taper conometric system may provide fixed retention between implants and dental prostheses. The aim of this study was to investigate retentive performance and mechanical strength of a Morse taper conometric system used as implant-supported fixed dental prostheses retention. Experimental and finite element investigations were performed. Experimental tests were achieved on a specific abutment-coping system, accounting for both cemented and non-cemented situations. The results from the experimental activities were processed to identify the mechanical behavior of the coping-abutment interface. Finally, the achieved information was applied to develop reliable finite element models of different abutment-coping systems. The analyses were developed accounting for different geometrical conformations of the abutment-coping system, such as different taper angle. The results showed that activation process, occurred through a suitable insertion force, could provide retentive performances equal to a cemented system without compromising the mechanical functionality of the system. These findings suggest that Morse taper conometrical system can provide a fixed connection between implants and dental prostheses if proper insertion force is applied. Activation process does not compromise the mechanical functionality of the system. © IMechE 2014.
Bacchiocchi, Danilo
2017-01-01
Purpose To present a new intraoral welding technique, which can be used to manufacture screw-retained, mandibular fixed full-arch prostheses. Methods Over a 4-year period, all patients with complete mandibular edentulism or irreparably compromised mandibular dentition, who will restore the masticatory function with a fixed mandibular prosthesis, were considered for inclusion in this study. The “Ball Welding Bar” (BWB) technique is characterised by smooth prosthetic cylinders, interconnected by means of titanium bars which are adjustable in terms of distance from ball terminals and are inserted in the rotating rings of the cylinders. All the components are welded and self-posing. Results Forty-two patients (18 males; 24 females; mean age 64.2 ± 6.7 years) were enrolled and 210 fixtures were inserted to support 42 mandibular screw-retained, fixed full-arch prostheses. After two years of loading, 2 fixtures were lost, for an implant survival rate of 97.7%. Five implants suffered from peri-implant mucositis and 3 implants for peri-implantitis. Three of the prostheses (3/42) required repair for fracture (7.1%): the prosthetic success was 92.9%. Conclusions The BWB technique seems to represent a reliable technique for the fabrication of screw-retained mandibular fixed full-arch prostheses. This study was registered in the ISRCTN register with number ISRCTN71229338. PMID:28835752
Ortorp, A; Jemt, T
1999-01-01
Titanium frameworks have been used in the endentulous implant patient for the last 10 years. However, knowledge of titanium frameworks for the partially dentate patient is limited. To report the 5-year clinical performance of implant-supported prostheses with laser-welded titanium frameworks in the partially edentulous jaw. A consecutive group of 383 partially edentulous patients were, on a routine basis, provided with fixed partial prostheses supported by Brånemark implants in the mandible or maxilla. Besides conventional frameworks in cast gold alloy, 58 patients were provided with titanium frameworks with three different veneering techniques, and clinical and radiographic 5-year data were collected for this group. The overall cumulative survival rate was 95.6% for titanium-framework prostheses and 93.6% for implants. Average bone loss during the follow-up period was 0.4 mm. The most common complications were minor veneering fractures. Loose and fractured implant screw components were fewer than 2%. An observation was that patients on medications for cardiovascular problems may lose more implants than others (p < .05). The clinical performance of prostheses with implant-supported laser-welded titanium frameworks was similar to that reported for conventional cast frames in partially edentulous jaws. Low-fusing porcelain veneers also showed clinical performance comparable to that reported for conventional porcelain-fused-to-metal techniques.
A first experience with digital complete overdentures.
Bajunaid, Salwa Omar
2016-07-01
The development of computer-aided design/computer-aided manufacturing systems for dentistry in the 1980s resulted in the successful fabrication of crowns, fixed dental prostheses, and superstructures for both natural teeth and dental implants. Today, this technology is available for constructing digitally designed and milled, completely removable dental prostheses. The procedure uses clinical and laboratory protocols that allow fabrication of completely removable prostheses within two clinical appointments. The aim of this clinical report is to present the author's first experience with digital complete overdentures, the practicality of this technology, and patient feedback. Compared with conventional overdentures, the fit of the digital prostheses was improved because the cameo and flanges of the prostheses were nicely shaped and rolled, and this enhanced their stability and retention. Occlusion was also excellent. However, aesthetics in terms of the alignment, shape, and size of the maxillary overdenture teeth were inacceptable. Despite some of the drawbacks identified in our study, the use of removable digital dentures does provide excellent adaptation of the denture base and requires fewer clinic visits. We anticipate that the unsatisfactory aesthetic outcomes presented in this report can be corrected with more experience. We also believe that acquiring an in-house scanning machine would be beneficial. We highly recommend including this technique in dental school curriculums at both the undergraduate and graduate levels in order to keep students and residents up to date on the latest technology available.
21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...
21 CFR 888.3690 - Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Shoulder joint humeral (hemi-shoulder) metallic... Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis. (a) Identification. A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium...
21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...
21 CFR 888.3690 - Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Shoulder joint humeral (hemi-shoulder) metallic... Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis. (a) Identification. A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium...
21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...
21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...
21 CFR 888.3690 - Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Shoulder joint humeral (hemi-shoulder) metallic... Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis. (a) Identification. A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium...
21 CFR 888.3680 - Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Shoulder joint glenoid (hemi-shoulder) metallic... Shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis. (a) Identification. A shoulder joint glenoid (hemi-shoulder) metallic cemented prosthesis is a device that has a glenoid (socket) component...
21 CFR 888.3690 - Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Shoulder joint humeral (hemi-shoulder) metallic... Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis. (a) Identification. A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium...
21 CFR 888.3690 - Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Shoulder joint humeral (hemi-shoulder) metallic... Shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis. (a) Identification. A shoulder joint humeral (hemi-shoulder) metallic uncemented prosthesis is a device made of alloys, such as cobalt-chromium...
Study of hydrogen bonding in ethanol-water binary solutions by Raman spectroscopy
NASA Astrophysics Data System (ADS)
Li, Fabing; Men, Zhiwei; Li, Shuo; Wang, Shenghan; Li, Zhanlong; Sun, Chenglin
2018-01-01
Raman spectra of ethanol-water binary solutions have been observed at room temperature and atmospheric pressure. We find that with increasing ethanol concentration, the symmetric and asymmetric Osbnd H stretching vibrational mode (3286 and 3434 cm- 1) of water are shifted to lower frequency and the weak shoulder peak at 3615 cm- 1 (free OH) disappears. These results indicate that ethanol strengthens hydrogen bonds in water. Simultaneously, our experiment shows that Raman shifts of ethanol reverses when the volume ratio of ethanol and the overall solution is 0.2, which demonstrates that ethanol-water structure undergoes a phase transition.
High-voltage R-F feedthrough bushing
Grotz, G.F.
1982-09-03
Described is a multi-element, high voltage radio frequency bushing for transmitting rf energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.
High voltage RF feedthrough bushing
Grotz, Glenn F.
1984-01-01
Described is a multi-element, high voltage radio frequency bushing for trmitting RF energy to an antenna located in a vacuum container. The bushing includes a center conductor of complex geometrical shape, an outer coaxial shield conductor, and a thin-walled hollow truncated cone insulator disposed between central and outer conductors. The shape of the center conductor, which includes a reverse curvature portion formed of a radially inwardly directed shoulder and a convex portion, controls the uniformity of the axial surface gradient on the insulator cone. The outer shield has a first substantially cylindrical portion and a second radially inwardly extending truncated cone portion.
Use and Usefulness of Lower Limb Prostheses.
ERIC Educational Resources Information Center
Buijk, Catharina A.
1988-01-01
Adults (n=181) in the Netherlands were surveyed concerning their use of lower limb prostheses. Results are analyzed in terms of age and sex of users, reason for amputation, level of amputation, description of prosthesis, amount of time able to walk or stand, satisfaction with the prosthesis, and user recommendations. (JDD)
Agile Development of Advanced Prototypes
2014-11-01
prostheses: retinal implants, cochlear implants, and neuroprosthetics (EEG controlled artificial limbs); an interactive, virtual experience...demonstrations allowing users to experience, from a patient’s perspective life with three different prostheses: retinal implants, cochlear implants...three experiences were researched and developed. The applications are interactive demonstrations of retinal implants, cochlear implants, and
Updates in inflatable penile prostheses.
Henry, Gerard D; Wilson, Steven K
2007-11-01
Throughout history, many attempts to correct erectile dysfunction (ED) have been recorded. For the last 35 years, intracavernosal inflatable prostheses have been used, and these devices have undergone almost constant enhancement. The three-piece inflatable penile prosthesis has the highest patient satisfaction rates and lowest mechanical revision rates of almost any medically implanted device.
Arthrographic and clinical findings in patients with hemiplegic shoulder pain.
Lo, Sui-Foon; Chen, Shu-Ya; Lin, Hsiu-Chen; Jim, Yick-Fung; Meng, Nai-Hsin; Kao, Mu-Jung
2003-12-01
To identify the etiology of hemiplegic shoulder pain by arthrographic and clinical examinations and to determine the correlation between arthrographic measurements and clinical findings in patients with hemiplegic shoulder pain. Case series. Medical center of a 1582-bed teaching institution in Taiwan. Thirty-two consecutive patients with hemiplegic shoulder pain within a 1-year period after first stroke were recruited. Not applicable. Clinical examinations included Brunnstrom stage, muscle spasticity distribution, presence or absence of subluxation and shoulder-hand syndrome, and passive range of motion (PROM) of the shoulder joint. Arthrographic measurements included shoulder joint volume and capsular morphology. Most patients had onset of hemiplegic shoulder pain less than 2 months after stroke. Adhesive capsulitis was the main cause of shoulder pain, with 50% of patients having adhesive capsulitis, 44% having shoulder subluxation, 22% having rotator cuff tears, and 16% having shoulder-hand syndrome. Patients with adhesive capsulitis showed significant restriction of passive shoulder external rotation and abduction and a higher incidence of shoulder-hand syndrome (P=.017). Those with irregular capsular margins had significantly longer shoulder pain duration and more restricted passive shoulder flexion (P=.017) and abduction (P=.020). Patients with shoulder subluxation had significantly larger PROM (flexion, P=.007; external rotation, P<.001; abduction, P=.001; internal rotation, P=.027), lower muscle tone (P=.001), and lower Brunnstrom stages of the proximal upper extremity (P=.025) and of the distal upper extremity (P=.001). Muscle spasticity of the upper extremity was slightly negatively correlated with shoulder PROM. Shoulder joint volume was moderately positively correlated with shoulder PROM. After investigating the hemiplegic shoulder joint through clinical and arthrographic examinations, we found that the causes of hemiplegic shoulder pain are complicated. Adhesive capsulitis was the leading cause of shoulder pain, followed by shoulder subluxation. Greater PROM of the shoulder joint, associated with larger joint volume, decreased the occurrence of adhesive capsulitis. Proper physical therapy and cautious handling of stroke patients to preserve shoulder mobility and function during early rehabilitation are important for a good outcome.
Peak-picking fundamental period estimation for hearing prostheses.
Howard, D M
1989-09-01
A real-time peak-picking fundamental period estimation device is described which is used in advanced hearing prostheses for the totally and profoundly deafened. The operation of the peak picker is compared with three well-established fundamental frequency estimation techniques: the electrolaryngograph, which is used as a "standard" hardware implementations of the cepstral technique, and the Gold/Rabiner parallel processing algorithm. These comparisons illustrate and highlight some of the important advantages and disadvantages that characterize the operation of these techniques. The special requirements of the hearing prostheses are discussed with respect to the operation of each device, and the choice of the peak picker is found to be felicitous in this application.
Manufacturing implant supported auricular prostheses by rapid prototyping techniques.
Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent
2011-08-01
Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses.
External breast prostheses. A survey of their use by women after mastectomy.
Tanner, R; Abraham, S F; Llewellyn-Jones, D
1983-03-19
Women who have had a mastectomy for breast cancer have to cope with two major problems: first, that they have cancer, and second, that they have lost their physical appearance. The provision of an appropriate prosthesis can reduce the sense of disfigurement. If women were to obtain the full psychological benefit of wearing a breast prosthesis, they need to be informed about the available breast forms, have an opportunity to choose between them, and to be satisfied with their choice. In this study of 49 women, only 44% had had the opportunity to choose a prosthesis, 28% were dissatisfied with their prostheses, and 17% were still using temporary prostheses.
Manzotti, A.; Montironi, F.; Pullen, C.
2008-01-01
Recently mini-invasive joint replacement has become one of the hottest topics in the orthopaedic world. However, these terms have been improperly misunderstood as a “key-hole” surgery where traditional components are implanted with shorter surgical approaches, with few benefits and several possible dangers. Small implants as unicompartmental knee prostheses, patellofemoral prostheses and bi-unicompartmental knee prostheses might represent real less invasive procedures: Tissue sparing surgery, the Italian way to minimally invasive surgery (MIS). According to their experience the authors go through this real tissue sparing surgery not limited only to a small incision, but where the surgeons can respect the physiological joint biomechanics. PMID:19384616
Biophysical synaptic dynamics in an analog VLSI network of Hodgkin-Huxley neurons.
Yu, Theodore; Cauwenberghs, Gert
2009-01-01
We study synaptic dynamics in a biophysical network of four coupled spiking neurons implemented in an analog VLSI silicon microchip. The four neurons implement a generalized Hodgkin-Huxley model with individually configurable rate-based kinetics of opening and closing of Na+ and K+ ion channels. The twelve synapses implement a rate-based first-order kinetic model of neurotransmitter and receptor dynamics, accounting for NMDA and non-NMDA type chemical synapses. The implemented models on the chip are fully configurable by 384 parameters accounting for conductances, reversal potentials, and pre/post-synaptic voltage-dependence of the channel kinetics. We describe the models and present experimental results from the chip characterizing single neuron dynamics, single synapse dynamics, and multi-neuron network dynamics showing phase-locking behavior as a function of synaptic coupling strength. The 3mm x 3mm microchip consumes 1.29 mW power making it promising for applications including neuromorphic modeling and neural prostheses.
Office-based andrology and male infertility procedures—a cost-effective alternative
Alom, Manaf; Ziegelmann, Matthew; Savage, Josh; Miest, Tanner; Köhler, Tobias S.
2017-01-01
Background From 2014–2016, our clinical practice progressively incorporated several male infertility and andrology procedures performed under local anesthesia, including circumcision, hydrocelectomy, malleable penile prostheses, orchiectomy, penile plication, spermatocelectomy, testicular prostheses, varicocelectomy, vasectomy reversal (VR), and testicular and microepididymal sperm aspiration (TESE/MESA). Given the observed outcomes and potential financial and logistical benefits of this approach for surgeons and patients, we sought to describe our initial experience. Methods A retrospective analysis was performed of all andrologic office-based (local anesthesia only) and select OR (general or monitored anesthesia care) procedures performed from 2014–2016. Financial and outcomes analyses were performed for infertility cases due to the homogeneity of payment modalities and number of cases available. Demographic, clinicopathologic, and procedural costs (direct and indirect) were reviewed and compared. Results A total of 32 VRs, 24 hydrocelectomies, 24 TESEs, 10 circumcisions, 9 MESA/TESEs, 4 spermatocelectomies, 3 orchiectomies (1 inguinal), 2 microTESEs, 2 testicular prostheses, 1 malleable penile prosthesis, 1 penile plication, and 1 varicocelectomy. Compared to the OR, male infertility procedures performed in the clinic with local anesthesia were performed for a fraction of the cost: MESA/TESE (78% reduction), TESE (89% reduction), and VR (62% reduction). All office-based procedures were completed successfully without significant modifications to technique. Outcomes were similar between the office and OR including operative time (VR: 181 vs. 190 min, P=0.34), rate of vasoepididymostomy (VE) (23% vs. 32%, P=0.56), total sperm counts (72.2 vs. 50.9 million, P=0.56), and successful sperm retrieval (MESA/TESE 100% vs. 100%, P=1.00; TESE 80% vs. 100%, P=0.36). To our knowledge, the current study also represents the first report of office-based VE under local anesthesia alone. For hydrocelectomy procedures, recurrence (4%) and hematoma (4%) rates were low (mean 4.2 months follow-up), although this likely relates to modifications with technique and not the anesthesia or operative setting. Overall, when given the choice, 86% of patients chose an office-based approach over the OR. Conclusions Office-based andrology procedures using local anesthesia may be successfully performed without compromising surgical technique or outcomes. This approach significantly reduces costs for patients and the overall healthcare system and has become our treatment modality of choice. PMID:28904909
Using Noncontingent Reinforcement to Increase Compliance with Wearing Prescription Prostheses
ERIC Educational Resources Information Center
Richling, Sarah M.; Rapp, John T.; Carroll, Regina A.; Smith, Jeanette N.; Nystedt, Aaron; Siewert, Brook
2011-01-01
We evaluated the effects of noncontingent reinforcement (NCR) on compliance with wearing foot orthotics and a hearing aid with 2 individuals. Results showed that NCR increased the participants' compliance with wearing prescription prostheses to 100% after just a few 5-min sessions, and the behavior change was maintained during lengthier sessions.…
[Image processing system of visual prostheses based on digital signal processor DM642].
Xie, Chengcheng; Lu, Yanyu; Gu, Yun; Wang, Jing; Chai, Xinyu
2011-09-01
This paper employed a DSP platform to create the real-time and portable image processing system, and introduced a series of commonly used algorithms for visual prostheses. The results of performance evaluation revealed that this platform could afford image processing algorithms to be executed in real time.
Composite Materials for Maxillofacial Prostheses.
1983-02-01
the most promise for producing elastomeric-shelled microcapsules containing an inert liquid. While much of the diverse field of microencapsulation is...Processes and Applications, Chicago, 28 August 1973. 11. Gutchko, M. H., Microcapsules and Microencapsulation Techniques. Noyes Data Corporation, Park Ridge...necesaryv and identify by block number) * MAXILLOFACIAL PROSTHESES; PROSTHETIC MATERIALS: MICROCAPSULES : * SOFT FILLERS; ELASTOMER COMPOSITES 2L
Nestola, M G C; Faggiano, E; Vergara, C; Lancellotti, R M; Ippolito, S; Antona, C; Filippi, S; Quarteroni, A; Scrofani, R
2017-02-01
We provide a computational comparison of the performance of stentless and stented aortic prostheses, in terms of aortic root displacements and internal stresses. To this aim, we consider three real patients; for each of them, we draw the two prostheses configurations, which are characterized by different mechanical properties and we also consider the native configuration. For each of these scenarios, we solve the fluid-structure interaction problem arising between blood and aortic root, through Finite Elements. In particular, the Arbitrary Lagrangian-Eulerian formulation is used for the numerical solution of the fluid-dynamic equations and a hyperelastic material model is adopted to predict the mechanical response of the aortic wall and the two prostheses. The computational results are analyzed in terms of aortic flow, internal wall stresses and aortic wall/prosthesis displacements; a quantitative comparison of the mechanical behavior of the three scenarios is reported. The numerical results highlight a good agreement between stentless and native displacements and internal wall stresses, whereas higher/non-physiological stresses are found for the stented case.
A system verification platform for high-density epiretinal prostheses.
Chen, Kuanfu; Lo, Yi-Kai; Yang, Zhi; Weiland, James D; Humayun, Mark S; Liu, Wentai
2013-06-01
Retinal prostheses have restored light perception to people worldwide who have poor or no vision as a consequence of retinal degeneration. To advance the quality of visual stimulation for retinal implant recipients, a higher number of stimulation channels is expected in the next generation retinal prostheses, which poses a great challenge to system design and verification. This paper presents a system verification platform dedicated to the development of retinal prostheses. The system includes primary processing, dual-band power and data telemetry, a high-density stimulator array, and two methods for output verification. End-to-end system validation and individual functional block characterization can be achieved with this platform through visual inspection and software analysis. Custom-built software running on the computers also provides a good way for testing new features before they are realized by the ICs. Real-time visual feedbacks through the video displays make it easy to monitor and debug the system. The characterization of the wireless telemetry and the demonstration of the visual display are reported in this paper using a 256-channel retinal prosthetic IC as an example.
Clinical Management of Implant Prostheses in Patients with Bruxism
Komiyama, Osamu; Lobbezoo, Frank; De Laat, Antoon; Iida, Takashi; Kitagawa, Tsuyoshi; Murakami, Hiroshi; Kato, Takao; Kawara, Misao
2012-01-01
There is general agreement that excessive stress to the bone-implant interface may result in implant overload and failure. Early failure of the implant due to excessive loading occurs shortly after uncovering the implant. Excess load on a final restoration after successful implant integration can result in physical failure of the implant structure. Many clinicians believe that overload of dental implants is a risk factor for vertical peri-implant bone loss and/or may be detrimental for the suprastructure in implant prostheses. It has been documented that occlusal parafunction, such as, bruxism (tooth grinding and clenching) affects the outcome of implant prostheses, but there is no evidence for a causal relation between the failures and overload of dental implants. In spite of this lack of evidence, often metal restorations are preferred instead of porcelain for patients in whom bruxism is presumed on the basis of tooth wear. The purpose of this paper is to discuss the importance of the occlusal scheme used in implant restorations for implant longevity and to suggest a clinical approach and occlusal materials for implant prostheses in order to prevent complications related to bruxism. PMID:22701484
Rodríguez-Lelis, Jose Maria; Mata, Dagoberto Tolosa; Vargas-Treviño, Marciano; Navarro-Torres, Jose; Piña-Piña, Gilberto; Abundez-Pliego, Arturo
2010-08-01
In the present work, based on high frequency wavelet analysis of dynamic signals of mechanical systems, a multiple-resolution wavelet analysis is carried out, to the signal obtained from an accelerometer mounted on the structure of a hip prosthesis wearing test device. The prostheses employed had a femoral head made of aluminum oxide and the acetabular cup of ultra-high-molecular-weight polyethylene. The first two aluminum oxide femoral heads were coated with diamond-like carbon and a third one was tested without coating and used as a reference. The coating was carried out by triboadhesion. Tests results showed that maximum vibration amplitude reached after 32 hr for the coated prostheses was 0.2 g. The noncoated prosthesis amplitude presented was 0.75 g in the same time interval. These values were attributed to wear damage on the surface of the prostheses, indicating that thin film DLC coating caused an increase of stiffness on the surface and therefore an increase in wear resistance approximately of 314%.
Nicholson, Thema; Maltenfort, Mitchell; Getz, Charles; Lazarus, Mark; Williams, Gerald; Namdari, Surena
2018-05-01
Our institution's traditional pain management strategy after shoulder arthroplasty has involved the utilization of postoperative patient-controlled narcotic analgesia. More recently, we have implemented a protocol (TLC) that utilizes a multimodal approach. The purpose of this study was to determine whether this change has improved pain control and decreased narcotic utilization. Patients undergoing primary total shoulder or reverse arthroplasty were retrospectively studied. All patients underwent interscalene brachial plexus blockade. "Traditional" patients were provided a patient-controlled analgesic pump postoperatively. TLC patients were given preoperative and postoperative multimodal, non-narcotic analgesic medications and breakthrough narcotics. Morphine equivalent units (MEU) consumed and Visual Analog Scale (VAS) scores for pain (0, 8, 16, and 24 hours) were considered. There were 108 patients in each group. Total postoperative narcotic consumption in the first 24 postoperative hours was 38.5 +/- 81.1 MEU in the "Traditional group" compared to 59.3 +/- 59.1 MEU in the TLC group ( P<0.001 ). Of patients in the TLC group, 88% utilized breakthrough narcotics. VAS pain was significantly higher in the "Traditional group" at 16 hours (4.1 +/- 2.9 vs 3.2 +/- 2.7, P=0.020 ) and 24 hours (4.8 +/- 2.7 vs 3.7 +/- 2.6, P=0.004 ). Those treated with the TLC protocol had greater narcotic utilization but better VAS pain scores at 24 hours after surgery. Both groups experienced rebound pain. While the TLC protocol led to an improved pain experience, further modification of the currently protocol may be necessary to reduce overall narcotic utilization.
Wu, Y J; Chen, S Y; Lin, M C; Lan, C; Lai, J S; Lien, I N
2001-02-01
To compare the energy expenditure of locomotion by wheelchair with that required for prosthetic ambulation in a person with bilateral transfemoral (TF) amputations. Observational, single patient, descriptive. An 80-meter long rectangular hallway in a rehabilitation unit. A 41-year-old woman with bilateral TF amputations that were performed 79 days before her admission to the rehabilitation unit. The oxygen uptake, oxygen cost, heart rate, speed, cadence, and stride length of walking measured during a 4-month course of prosthetic rehabilitation. Five locomotion conditions were evaluated: (1) wheelchair propulsion, (2) walking with short-leg prostheses (stubbies) and a walker, (3) long-leg prostheses and a walker, (4) long-leg prostheses without knee mechanism and axillary crutches, and (5) long-leg prostheses with right polycentric knee and left locked knee and axillary crutches. A portable and telemetric system was used to measure the metabolic parameters. An arm ergometry graded exercise test was performed at the end of rehabilitation. Oxygen cost (range, 466%--707% of that of wheeling) and heart rate (range, 106%--116% of that of wheeling) were higher during walking with various combinations of prostheses and walking aids. The speed of prosthetic walking was only 24% to 33% of that of wheeling. Our patient preferred using a wheelchair to prosthetic walking after discharge. People with bilateral TF amputations require very high cardiorespiratory endurance to fulfill the energy demand during prosthetic rehabilitation. The high energy cost of prosthetic walking will limit its application in daily activities.
Bone-anchored titanium implants for auricular rehabilitation: case report and review of literature.
Gumieiro, Emne Hammoud; Dib, Luciano Lauria; Jahn, Ricardo Schmitutz; Santos Junior, João Ferreira dos; Nannmark, Ulf; Granström, Gösta; Abrahão, Márcio
2009-01-01
Osseointegrated implants have acquired an important role in the prosthetic rehabilitation of patients with craniofacial defects. The main indications are lack of local tissue for autogenous reconstruction, previous reconstruction failure and selection of this technique by the patient. This paper presents a clinical case and discusses indications and advantages of the osseointegrated implant technique for retention of auricular prostheses. Case report, Universidade Federal de São Paulo (UNIFESP). A female patient received three auricular implants after surgical resection of a hemangioma in her left ear. The time taken for osseointegration of the temporal bone was three months. After fabrication of the implant-retained auricular prosthesis, the patient was monitored for 12 months. The clinical parameters evaluated showed good postoperative healing, healthy peri-implant tissue, good hygiene and no loss of implants. Good hygiene combined with thin and immobile peri-implant soft tissues resulted in minimal complications. Craniofacial implant integration appears to be site-dependent; increasing age affects osseointegration in the temporal bone. The frequency of adverse skin reactions in peri-implant tissues is generally low. The surgical technique for rehabilitation using implant-retained auricular prostheses seems to be simple. It is associated with low rates of adverse skin reactions and long-term complications. Prostheses anchored by osseointegrated implants seem to provide better retention than do prostheses supported on spectacle frames, less risk of discoloration through the use of adhesives and better esthetic results than do prostheses anchored in the surgical cavity.
Toward Optimal Target Placement for Neural Prosthetic Devices
Cunningham, John P.; Yu, Byron M.; Gilja, Vikash; Ryu, Stephen I.; Shenoy, Krishna V.
2008-01-01
Neural prosthetic systems have been designed to estimate continuous reach trajectories (motor prostheses) and to predict discrete reach targets (communication prostheses). In the latter case, reach targets are typically decoded from neural spiking activity during an instructed delay period before the reach begins. Such systems use targets placed in radially symmetric geometries independent of the tuning properties of the neurons available. Here we seek to automate the target placement process and increase decode accuracy in communication prostheses by selecting target locations based on the neural population at hand. Motor prostheses that incorporate intended target information could also benefit from this consideration. We present an optimal target placement algorithm that approximately maximizes decode accuracy with respect to target locations. In simulated neural spiking data fit from two monkeys, the optimal target placement algorithm yielded statistically significant improvements up to 8 and 9% for two and sixteen targets, respectively. For four and eight targets, gains were more modest, as the target layouts found by the algorithm closely resembled the canonical layouts. We trained a monkey in this paradigm and tested the algorithm with experimental neural data to confirm some of the results found in simulation. In all, the algorithm can serve not only to create new target layouts that outperform canonical layouts, but it can also confirm or help select among multiple canonical layouts. The optimal target placement algorithm developed here is the first algorithm of its kind, and it should both improve decode accuracy and help automate target placement for neural prostheses. PMID:18829845
Boscato, Noeli; Schuch, Helena S; Grasel, Claudia E; Goettems, Marilia L
2016-09-01
To assess differences in the oral diseases/conditions between adults and older adults. A cross-sectional study was carried out with all adults and older adults in Luzerna, South Brazil (n = 569). Clinical data included use of and need for dental prostheses; number of decayed, missing and filled teeth; and temporomandibular disorder. Differences between adults and older adults were evaluated using χ(2) -tests. Associations between independent variables and the use of and need for dental prostheses were determined using Poisson regression analyses (P < 0.05). Increased number of decayed, missing and filled teeth, use of and need for dental prostheses, higher use of complete dentures, and fewer temporomandibular disorder signs and symptoms were observed in older adults. After adjustments, lower social class (P = 0.001) and unmarried status (P = 0.05) were associated with greater need for prosthetic rehabilitation. Women (P = 0.02), older individuals (P < 0.001) and those of lower socioeconomic status (P = 0.001) had a higher risk of using prostheses. A significant difference of oral conditions between adults and older adults was observed. The frequency of use of and need for dental prostheses was higher for older adults, although they had reported lower frequency of temporomandibular disorder. Women, married and individuals of higher socioeconomic status showed better oral health conditions. Geriatr Gerontol Int 2016; 16: 1014-1020. © 2015 Japan Geriatrics Society.
Ice hockey shoulder pad design and the effect on head response during shoulder-to-head impacts.
Richards, Darrin; Ivarsson, B Johan; Scher, Irving; Hoover, Ryan; Rodowicz, Kathleen; Cripton, Peter
2016-11-01
Ice hockey body checks involving direct shoulder-to-head contact frequently result in head injury. In the current study, we examined the effect of shoulder pad style on the likelihood of head injury from a shoulder-to-head check. Shoulder-to-head body checks were simulated by swinging a modified Hybrid-III anthropomorphic test device (ATD) with and without shoulder pads into a stationary Hybrid-III ATD at 21 km/h. Tests were conducted with three different styles of shoulder pads (traditional, integrated and tethered) and without shoulder pads for the purpose of control. Head response kinematics for the stationary ATD were measured. Compared to the case of no shoulder pads, the three different pad styles significantly (p < 0.05) reduced peak resultant linear head accelerations of the stationary ATD by 35-56%. The integrated shoulder pads reduced linear head accelerations by an additional 18-21% beyond the other two styles of shoulder pads. The data presented here suggest that shoulder pads can be designed to help protect the head of the struck player in a shoulder-to-head check.
3D-printed upper limb prostheses: a review.
Ten Kate, Jelle; Smit, Gerwin; Breedveld, Paul
2017-04-01
This paper aims to provide an overview with quantitative information of existing 3D-printed upper limb prostheses. We will identify the benefits and drawbacks of 3D-printed devices to enable improvement of current devices based on the demands of prostheses users. A review was performed using Scopus, Web of Science and websites related to 3D-printing. Quantitative information on the mechanical and kinematic specifications and 3D-printing technology used was extracted from the papers and websites. The overview (58 devices) provides the general specifications, the mechanical and kinematic specifications of the devices and information regarding the 3D-printing technology used for hands. The overview shows prostheses for all different upper limb amputation levels with different types of control and a maximum material cost of $500. A large range of various prostheses have been 3D-printed, of which the majority are used by children. Evidence with respect to the user acceptance, functionality and durability of the 3D-printed hands is lacking. Contrary to what is often claimed, 3D-printing is not necessarily cheap, e.g., injection moulding can be cheaper. Conversely, 3D-printing provides a promising possibility for individualization, e.g., personalized socket, colour, shape and size, without the need for adjusting the production machine. Implications for rehabilitation Upper limb deficiency is a condition in which a part of the upper limb is missing as a result of a congenital limb deficiency of as a result of an amputation. A prosthetic hand can restore some of the functions of a missing limb and help the user in performing activities of daily living. Using 3D-printing technology is one of the solutions to manufacture hand prostheses. This overview provides information about the general, mechanical and kinematic specifications of all the devices and it provides the information about the 3D-printing technology used to print the hands.
Örtorp, Anders; Jemt, Torsten
2012-03-01
No long-term clinical studies covering more than 5 years are available on Computer Numeric Controlled (CNC) milled titanium frameworks. To evaluate and compare the clinical and radiographic performance of implant-supported prostheses provided with CNC titanium frameworks in the edentulous jaw with prostheses with cast gold-alloy frameworks during the first 10 years of function. Altogether, 126 edentulous patients were by random provided with 67 prostheses with titanium frameworks (test) in 23 maxillas and 44 mandibles, and with 62 prostheses with gold-alloy castings (control) in 31 maxillas and 31 mandibles. Clinical and radiographic 10-year data were collected for the groups and statistically compared on patient level. The 10-year prosthesis and implant cumulative survival rate was 95.6% compared with 98.3%, and 95.0% compared with 97.9% for test and control groups, respectively (p > .05). No implants were lost after 5 years of follow-up. Smokers lost more implants than nonsmokers after 5 years of follow-up (p < .01). Mean marginal bone loss in the test group was 0.7 mm (SD 0.61) and 0.7 mm (SD 0.85) in the maxilla and mandible, with similar pattern in the control group (p > .05), respectively. One prosthesis was lost in each group due to loss of implants, and one prosthesis failed due to framework fracture in the test group. Two metal fractures were registered in each group. More appointments of maintenance were needed for the prostheses in the maxilla compared with those in the mandible (p < .001). The frequency of complications was low with similar clinical and radiological performance for both groups during 10 years. CNC-milled titanium frameworks are a viable alternative to gold-alloy castings for restoring patients with implant-supported prostheses in the edentulous jaw. © 2009 Wiley Periodicals, Inc.
Palomares, Teresa; Montero, Javier; Rosel, Eva M; Del-Castillo, Ramón; Rosales, Juan I
2018-05-01
The impact of conventional prosthetic treatment on both the objective and subjective assessments of mastication as well as on well-being is unclear. The purpose of this clinical study was to compare the impact on oral health-related quality of life and masticatory function in participants treated with conventional dental prostheses. A total of 72 patients requiring prosthetic rehabilitation were enrolled by referral from the Faculty of Dentistry at the University of Granada, Spain. At baseline, demographic, behavioral, and clinical (prosthetic status, occlusal units) data were collected. In addition, the scores for quality of life, oral satisfaction, masticatory ability (Leake index), and masticatory performance (after 5, 10, and 15 cycles of bicolored chewing gum) were obtained. These records were obtained again at 6 to 8 weeks after insertion of the prostheses. The findings revealed that patients treated with fixed prostheses had better quality of life and better masticatory function than patients treated with removable prostheses. This result was even more pronounced for those treated with complete dentures. For all items, most of the treated patients improved the quality of life (average, 8.6 of the 4 items), although only between 5% and 15% of patients, especially those with a removable prosthesis, commented on functional impact after receiving treatment. Generally, masticatory performance was improved between 7% and 18% and was highly correlated not only with the number of natural teeth (r=0.61) and occlusal units (r=0.51) but also with subjective variables such as mastication satisfaction (r=0.31), impact on quality of life (r=0.30), or masticatory ability (r=0.30). Treatment with fixed prostheses achieved better results regarding quality of life, oral satisfaction, and masticatory function than treatment with removable prostheses. A moderate but significant correlation exists between the objective and subjective assessments of the masticatory functions. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Li, Xiao-ye; Yan, Ai-hui; Hao, Shuai; Li, Wei; Jiang, Xue-jun; Lu, Li; Qin, Xing-jun; Yan, Hai-xin
2011-05-01
The feasibility and clinical effects of hollow obturator prosthesis for the repair of maxillofacial defect immediately after maxillectomy for cancer were assessed. Thirteen patients with T3-4aN0M0 maxillary neoplasm were treated by the prostheses immediately after maxillectomy. According to the 3D-CT reconstruction of nasal sinus, the 3D stereoscopic prototype was constructed before the surgery. Simulating surgery with Surgicare 5.0 software and then the prosthesis 3D stereoscopic model was shaped. The prosthesis was made quickly and precisely with methacrylate resins according to the model and the print mold before surgery, with supplementary tooth at the bottom of prosthesis. In the surgery, the prosthesis was installed instantly after maxillectomy. The patients were followed up at 1, 3 and 6 month after the surgery, respectively. The facial features and the pronunciation clarity were examined and the questionnaires were carried out in the patients, with comparation by paired t-test. The hollow obturator prosthesis would be replaced by permanent prosthesis made of methacrylate resins at 6 month after the surgery. The hollow obturator prostheses were installed accurately and maxillofacial defects were repaired immediately after maxillectomy in the 13 patients. Postoperative follow-up showed there were significant differences in eyeball sagging (t = 4.67, P < 0.05), mid-facial region collapse (t = 5.67, P < 0.05), and pronunciation clarity (t = 16.38, P < 0.05) between patients with and without prostheses. Questionnaires showed that all the patients were satisfied with the retention of prostheses, the improvement of appearance, the improvement of the symptom of water choking and speech definition. Six months after the surgery, the hollow obturator prostheses were replaced smoothly by permanent prostheses in 11 of the 13 patients. The precise and instant repair of maxillofacial defect by prosthesis after maxillectomy can improve survival quality of patient.
Morsbach, Fabian; Bickelhaupt, Sebastian; Wanner, Guido A; Krauss, Andreas; Schmidt, Bernhard; Alkadhi, Hatem
2013-07-01
To assess the value of iterative frequency split-normalized (IFS) metal artifact reduction (MAR) for computed tomography (CT) of hip prostheses. This study had institutional review board and local ethics committee approval. First, a hip phantom with steel and titanium prostheses that had inlays of water, fat, and contrast media in the pelvis was used to optimize the IFS algorithm. Second, 41 consecutive patients with hip prostheses who were undergoing CT were included. Data sets were reconstructed with filtered back projection, the IFS algorithm, and a linear interpolation MAR algorithm. Two blinded, independent readers evaluated axial, coronal, and sagittal CT reformations for overall image quality, image quality of pelvic organs, and assessment of pelvic abnormalities. CT attenuation and image noise were measured. Statistical analysis included the Friedman test, Wilcoxon signed-rank test, and Levene test. Ex vivo experiments demonstrated an optimized IFS algorithm by using a threshold of 2200 HU with four iterations for both steel and titanium prostheses. Measurements of CT attenuation of the inlays were significantly (P < .001) more accurate for IFS when compared with filtered back projection. In patients, best overall and pelvic organ image quality was found in all reformations with IFS (P < .001). Pelvic abnormalities in 11 of 41 patients (27%) were diagnosed with significantly (P = .002) higher confidence on the basis of IFS images. CT attenuation of bladder (P < .001) and muscle (P = .043) was significantly less variable with IFS compared with filtered back projection and linear interpolation MAR. In comparison with that of FBP and linear interpolation MAR, noise with IFS was similar close to and far from the prosthesis (P = .295). The IFS algorithm for CT image reconstruction significantly reduces metal artifacts from hip prostheses, improves the reliability of CT number measurements, and improves the confidence for depicting pelvic abnormalities.
Fracture analysis of randomized implant-supported fixed dental prostheses
Esquivel-Upshaw, Josephine F.; Mehler, Alex; Clark, Arthur E.; Neal, Dan; Anusavice, Kenneth J.
2014-01-01
Objective Fractures of posterior fixed dental all-ceramic prostheses can be caused by one or more factors including prosthesis design, flaw distribution, direction and magnitude of occlusal loading, and nature of supporting infrastructure (tooth root/implant), and presence of adjacent teeth. This clinical study of implant-supported, all-ceramic fixed dental prostheses, determined the effects of (1) presence of a tooth distal to the most distal retainer; (2) prosthesis loading either along the non-load bearing or load bearing areas; (3) presence of excursive contacts or maximum intercuspation contacts in the prosthesis; and (4) magnitude of bite force on the occurrence of veneer ceramic fracture. Methods 89 implant-supported FDPs were randomized as either a three-unit posterior metal-ceramic (Au-Pd-Ag alloy and InLine POM, Ivoclar, Vivadent) FDP or a ceramic-ceramic (ZirCAD and ZirPress, Ivoclar, Vivadent) FDP. Two implants (Osseospeed, Dentsply) and custom abutments (Atlantis, Dentsply) supported these FDPs, which were cemented with resin cement (RelyX Universal Cement). Baseline photographs were made with markings of teeth from maximum intercuspation (MI) and excursive function. Patients were recalled at 6 months and 1 to 3 years. Fractures were observed, their locations recorded, and images compared with baseline photographs of occlusal contacts. Conclusion No significant relationship exists between the occurrence of fracture and: (1) the magnitude of bite force; (2) a tooth distal to the most distal retainer; and (3) contacts in load-bearing or non-load-bearing areas. However, there was a significantly higher likelihood of fracture in areas with MI contacts only. Clinical Significance This clinical study demonstrates that there is a need to evaluate occlusion differently with implant-supported prostheses than with natural tooth supported prostheses because of the absence of a periodontal ligament. Implant supported prostheses should have minimal occlusion and lighter contacts than ones supported by natural dentition. PMID:25016139
Boileau, Pascal; Morin-Salvo, Nicolas; Gauci, Marc-Olivier; Seeto, Brian L; Chalmers, Peter N; Holzer, Nicolas; Walch, Gilles
2017-12-01
Glenoid deficiency and erosion (excessive retroversion/inclination) must be corrected in reverse shoulder arthroplasty (RSA) to avoid prosthetic notching or instability and to maximize function, range of motion, and prosthesis longevity. This study reports the results of RSA with an angled, autologous glenoid graft harvested from the humerus (angled BIO-RSA). A trapezoidal bone graft, harvested from the humeral head and fixed with a long-post baseplate and screws, was used to compensate for residual glenoid bone loss/erosion. For simple to moderate (<25°) glenoid defects, standardized instrumentation combined with some eccentric reaming (<15°) was used to reconstruct the glenoid and obtain neutral implant alignment. For severe (>25°) and complex (multiplanar) glenoid bone defects, patient-specific grafts and guides were used after 3-dimensional planning. Patients were reviewed with minimum 2 years of follow-up. Mean follow-up was 36 months (range, 24-81 months). Preoperative and postoperative measurements of inclination and version were performed in the plane of the scapula on computed tomography images. The study included 54 patients (41 women, 13 men; mean 73 years old). Fifteen patients had combined vertical and horizontal glenoid bone deficiency. Among E2/E3 glenoids, inclination improved from 37° (range, 14° to 84°) to 10.2° (range -28° to 36°, P < .001). Among B2/C glenoids, retroversion improved from -21° (range, -49° to 0°) to -10.6° (-32° to 4°, P = .06). Complete radiographic incorporation of the graft occurred in 94% (51 of 54). Complications included infection in 1 and clinical aseptic baseplate loosening in 2. Mild notching occurred in 25% (13 of 51) of patients. Constant-Murley and Subjective Shoulder Value assessments increased from 31 to 68 and from 30% to 83%, respectively (P < .001). Angled BIO-RSA predictably corrects glenoid deficiency, including severe (>25°) multiplanar deformity. Graft incorporation is predictable. Advantages of using an autograftharvested in situ include bone stock augmentation, lateralization, low donor-site morbidity, low relative cost, and flexibility needed to simultaneously correct posterior and superior glenoid defects. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
An investigation of shoulder forces in active shoulder tackles in rugby union football.
Usman, Juliana; McIntosh, Andrew S; Fréchède, Bertrand
2011-11-01
In rugby union football the tackle is the most frequently executed skill and one most associated with injury, including shoulder injury to the tackler. Despite the importance of the tackle, little is known about the magnitude of shoulder forces in the tackle and influencing factors. The objectives of the study were to measure the shoulder force in the tackle, as well as the effects of shoulder padding, skill level, side of body, player size, and experimental setting on shoulder force. Experiments were conducted in laboratory and field settings using a repeated measures design. Thirty-five participants were recruited to the laboratory and 98 to the field setting. All were male aged over 18 years with rugby experience. The maximum force applied to the shoulder in an active shoulder tackle was measured with a custom built forceplate incorporated into a 45 kg tackle bag. The overall average maximum shoulder force was 1660 N in the laboratory and 1997 N in the field. This difference was significant. The shoulder force for tackling without shoulder pads was 1684 N compared to 1635 N with shoulder pads. There was no difference between the shoulder forces on the dominant and non-dominant sides. Shoulder force reduced with tackle repetition. No relationship was observed between player skill level and size. A substantial force can be applied to the shoulder and to an opponent in the tackle. This force is within the shoulder's injury tolerance range and is unaffected by shoulder pads. Copyright © 2011 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Porps, torps, and homografts in tympanoplasty.
Gillanders, D A; Cambon, K G; Doyle, P J
1980-04-01
A brief review of the use of plastique prostheses in ossiculoplasty, as well as the use of homograft tympanic membranes along with our experience is reported. Plastipore prostheses have been found to be useful, and their continued use is advocated. Homograft tympanic membranes are useful in repairing those ears which have undergone extensive damage to the tympanic membrane and ossicles.
Dental claims in the Swedish Patient Insurance Scheme.
René, N; Owall, B; Cronström, R
1991-06-01
The Swedish Patient Insurance Scheme covers treatment injuries and guarantees the replacement of failed removable prostheses for 1 year and fixed prostheses for 2 years after fitting. In this paper, 573 dental cases are analysed for a 3-month period in 1986, during which crowns and bridges formed the vast majority of failed treatments that were reported.
Manufacturing Implant Supported Auricular Prostheses by Rapid Prototyping Techniques
Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent
2011-01-01
Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses. PMID:21912504
NASA Astrophysics Data System (ADS)
Hoskin, HLD; Furie, E.; Collins, W.; Ganey, TM; Schlatterer, DR
2017-05-01
Since Sir John Charnley began his monumental hip arthroplasty work in 1958, clinical researchers have been incrementally improving longevity and functionality of total joint systems, although implant failure occurs on occasion. The purpose of this study is to report the fracture of the humeral tray Morse taper of a reverse total shoulder system (RTSS), which to date has not been reported with metallurgic analysis for any RTSS. There was no reported antecedent fall, motor vehicle collision, or other traumatic event prior to implant fracture in this case. Analysis was performed on the retrieved failed implant by Scanning Electron Microscopy (SEM) and Electron Dispersion Spectroscopy (EDS) in an attempt to determine the failure method, as well as to offer improvements for future implants. At the time of revision surgery all explants were retained from the left shoulder of a 61-year old male who underwent a non-complicated RTSS 4 years prior. The explants, particularly the cracked humeral tray, were processed as required for SEM and EDS. Analysis was performed on the failure sites in order to determine the chemical composition of the different parts of the implant, discover the chemical composition of the filler metal used during the electron beam welding process, and to detect any foreign elements that could suggest corrosion or other evidence of failure etiology. Gross visual inspection of all explants revealed that implant failure was a result of dissociation of the taper from the humeral tray at the weld, leaving the Morse taper embedded in the humeral stem while the tray floated freely in the patient’s shoulder. SEM further confirmed the jagged edges noted grossly at the weld fracture site, both suggesting failure due to torsional forces. EDS detected elevated levels of carbon and oxygen at the fracture site on the taper only and not on the humeral tray. In order to determine the origin of the high levels of C and O, it was considered that in titanium alloys, C and O are used as stabilizers that help raise the temperature at which titanium can be cast. Since the presence of stabilizers reduces ductility and fatigue strength, all interstitial elements are removed after casting. Considering this, the presence of C and O suggests that not all of the interstitials were removed during the manufacturing process, resulting in decreased fatigue strength. Further destructive analytical testing would verify weld quality and failure mode. RTSSs are quite successful in select patients not amenable to traditional shoulder arthroplasty options. This case report highlights how an implant may function well for several years and then suddenly fail without warning. SEM and EDS analysis suggest that residual C and O in the taper lowered the metal implant’s integrity, leading to torsional cracking at the weld junction of the humeral tray and the taper. The elevated levels of C and O measured at fracture sites on both the tray and the taper suggest poor quality filler metal or failure to remove all interstitial elements after casting. In both cases, the results would be decreased fatigue strength and overall toughness, leading to mechanical failure. A manufacturer’s recall of all implants soon followed the reporting of this implant failure; subsequently, the metal materials were changed from Ti6Al4V to both titanium alloy and cobalt-chrome alloy (Co-Cr-Mo). Time will tell if the alterations were sufficient.
Shoulder pain and concomitant hand oedema among stroke patients with pronounced arm paresis
2013-01-01
Background The aim of this prospective study was to identify clinical factors associated with the development of shoulder pain in stroke patients with pronounced arm paresis. Methods At stroke onset, 485 patients were initially assessed in 2007–2009. Sixty-three patients with pronounced arm paresis completed the study, and 21 of these developed shoulder pain. Clinical findings were recorded fortnightly by the attending physiotherapist during hospital stay. Results Hand oedema on the paretic side was more common in patients developing shoulder pain compared with those who did not develop shoulder pain. The onset of shoulder pain was associated with concomitant hand oedema. High NIHSS score was associated with developing shoulder pain. Patients with a history of shoulder pain developed pain earlier than those without previous shoulder pain. Patients with haemorrhagic stroke were significantly more prone to developing shoulder pain. Conclusions One-third of the stroke patients with pronounced arm paresis developed shoulder pain. Concomitant hand oedema seems to be an additional symptom of shoulder injury. Patients with low general status are more vulnerable to develop post-stroke shoulder pain. PMID:24765589
Lumbreras, Vicente; Bas, Esperanza; Gupta, Chhavi
2014-01-01
Cochlear implants are currently the most effective solution for profound sensorineural hearing loss, and vestibular prostheses are under development to treat bilateral vestibulopathies. Electrical current spread in these neuroprostheses limits channel independence and, in some cases, may impair their performance. In comparison, optical stimuli that are spatially confined may result in a significant functional improvement. Pulsed infrared radiation (IR) has previously been shown to elicit responses in neurons. This study analyzes the response of neonatal rat spiral and vestibular ganglion neurons in vitro to IR (wavelength = 1,863 nm) using Ca2+ imaging. Both types of neurons responded consistently with robust intracellular Ca2+ ([Ca2+]i) transients that matched the low-frequency IR pulses applied (4 ms, 0.25–1 pps). Radiant exposures of ∼637 mJ/cm2 resulted in continual neuronal activation. Temperature or [Ca2+] variations in the media did not alter the IR-evoked transients, ruling out extracellular Ca2+ involvement or primary mediation by thermal effects on the plasma membrane. While blockage of Na+, K+, and Ca2+ plasma membrane channels did not alter the IR-evoked response, blocking of mitochondrial Ca2+ cycling with CGP-37157 or ruthenium red reversibly inhibited the IR-evoked [Ca2+]i transients. Additionally, the magnitude of the IR-evoked transients was dependent on ryanodine and cyclopiazonic acid-dependent Ca2+ release. These results suggest that IR modulation of intracellular calcium cycling contributes to stimulation of spiral and vestibular ganglion neurons. As a whole, the results suggest selective excitation of neurons in the IR beam path and the potential of IR stimulation in future auditory and vestibular prostheses. PMID:24920028
Lumbreras, Vicente; Bas, Esperanza; Gupta, Chhavi; Rajguru, Suhrud M
2014-09-15
Cochlear implants are currently the most effective solution for profound sensorineural hearing loss, and vestibular prostheses are under development to treat bilateral vestibulopathies. Electrical current spread in these neuroprostheses limits channel independence and, in some cases, may impair their performance. In comparison, optical stimuli that are spatially confined may result in a significant functional improvement. Pulsed infrared radiation (IR) has previously been shown to elicit responses in neurons. This study analyzes the response of neonatal rat spiral and vestibular ganglion neurons in vitro to IR (wavelength = 1,863 nm) using Ca(2+) imaging. Both types of neurons responded consistently with robust intracellular Ca(2+) ([Ca(2+)]i) transients that matched the low-frequency IR pulses applied (4 ms, 0.25-1 pps). Radiant exposures of ∼637 mJ/cm(2) resulted in continual neuronal activation. Temperature or [Ca(2+)] variations in the media did not alter the IR-evoked transients, ruling out extracellular Ca(2+) involvement or primary mediation by thermal effects on the plasma membrane. While blockage of Na(+), K(+), and Ca(2+) plasma membrane channels did not alter the IR-evoked response, blocking of mitochondrial Ca(2+) cycling with CGP-37157 or ruthenium red reversibly inhibited the IR-evoked [Ca(2+)]i transients. Additionally, the magnitude of the IR-evoked transients was dependent on ryanodine and cyclopiazonic acid-dependent Ca(2+) release. These results suggest that IR modulation of intracellular calcium cycling contributes to stimulation of spiral and vestibular ganglion neurons. As a whole, the results suggest selective excitation of neurons in the IR beam path and the potential of IR stimulation in future auditory and vestibular prostheses. Copyright © 2014 the American Physiological Society.
Arthroscopic treatment options for irreparable rotator cuff tears of the shoulder
Anley, Cameron M; Chan, Samuel KL; Snow, Martyn
2014-01-01
The management of patients with irreparable rotator cuff tears remains a challenge for orthopaedic surgeons with the final treatment option in many algorithms being either a reverse shoulder arthroplasty or a tendon transfer. The long term results of these procedures are however still widely debated, especially in younger patients. A variety of arthroscopic treatment options have been proposed for patients with an irreparable rotator cuff tear without the presence of arthritis of the glenohumeral joint. These include a simple debridement with or without a biceps tenotomy, partial rotator cuff repair with or without an interval slide, tuberplasty, graft interposition of the rotator cuff, suprascapular nerve ablation, superior capsule reconstruction and insertion of a biodegradable spacer (Inspace) to depress the humeral head. These options should be considered as part of the treatment algorithm in patients with an irreparable rotator cuff and could be used as either as an interim procedure, delaying the need for more invasive surgery in the physiologically young and active, or as potential definitive procedures in the medically unfit. The aim of this review is to highlight and summarise arthroscopic procedures and the results thereof currently utilised in the management of these challenging patients. PMID:25405083
Møller, Sanne Pagh; Brauer, Charlotte; Mikkelsen, Sigurd; Alkjær, Tine; Koblauch, Henrik; Pedersen, Ellen Bøtker; Simonsen, Erik B; Thygesen, Lau Caspar
2018-04-01
Musculoskeletal shoulder load among baggage handlers measured by combining duration and intensity based on biomechanical and epidemiological information may be a stronger predictor of subacromial shoulder disorders than baggage handler seniority. In 2012, a cohort of baggage handlers employed at Copenhagen Airport in 1990-2012, and a cohort of unskilled otherwise employed men answered a survey. Self-reported information on work tasks during employment in the airport in combination with work task specific biomechanically modelled forces in the shoulder joint was used to estimate shoulder load. Exposure measures were accumulated shoulder abduction moment, accumulated shoulder compression force, accumulated supraspinatus force and baggage handler seniority. The outcome was subacromial shoulder disorder registered in the Danish National Patient Register. When analyses were adjusted by all confounders except age, exposure variables showed close to significant associations with subacromial shoulder disorder. Results could not confirm our hypothesis that combined information on work task duration and shoulder load intensity was stronger associated with subacromial shoulder disorder than seniority. Practitioner Summary: In this study we sought to identify if the exposure to work-related musculoskeletal shoulder loading including duration and intensity among baggage handlers was associated with subacromial shoulder disorder. We found that there was an association but this was not stronger than that between baggage handler seniority and subacromial shoulder disorder.
Muscular imbalance and shoulder pain in volleyball attackers.
Kugler, A; Krüger-Franke, M; Reininger, S; Trouillier, H H; Rosemeyer, B
1996-01-01
OBJECTIVE: In overhead sports such as volleyball, baseball, or tennis shoulder problems are very common. The aim of this study was to identify features which may correlate with shoulder problems in volleyball attackers. METHODS: 30 competitive volleyball attackers (mean age 25 years) were included in the study; 15 were suffering from shoulder pain and 15 had no history of shoulder pain. The results were compared with those of a control group of 15 recreational athletes without any overhead sports activities. RESULTS: Volleyball attackers have a different muscular and capsular pattern at the playing shoulder compared to the opposite shoulder. Their playing shoulder is depressed, the scapula lateralised, and the dorsal muscles and the posterior and inferior part of the shoulder capsule shortened. These differences were of more significance in volleyball attackers with shoulder pain than in volleyball players without shoulder pain. In contrast to recreational athletes without any overhead sports activity, there were no significant difference in the comparison of the two shoulders. The histories, clinical and sonographic findings did not reveal further typical features for volleyball attackers with shoulder pain. CONCLUSIONS: Muscular balance of the shoulder girdle is very important in this sport. It is therefore imperative to include adequate stretching and muscular training programme for the prevention, as well as for therapy, of shoulder pain in volleyball attackers. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 PMID:8889124
Hatchett, Patricia; Eberly, Valerie J.; Lighthall Haubert, Lisa; Conners, Sandy; Requejo, Philip S.
2015-01-01
Background Shoulder joint pain is a frequent secondary complaint for people following spinal cord injury (SCI). Objective The purpose of this study was to determine predictors of shoulder joint pain in people with paraplegia. Methods/Design A 3-year longitudinal study was conducted. Participants were people with paraplegia who used a manual wheelchair for at least 50% of their mobility and were asymptomatic for shoulder pain at study entry. Participants were classified as having developed shoulder pain if they experienced an increase of ≥10 points on the Wheelchair User's Shoulder Pain Index in the 3-year follow-up period. Measurements of maximal isometric shoulder torques were collected at study entry (baseline), 18 months, and 3 years. Daily activity was measured using a wheelchair odometer, and self-reported daily transfer and raise frequency data were collected by telephone every 6 weeks. Results Two hundred twenty-three participants were enrolled in the study; 39.8% developed shoulder pain over the 3-year follow-up period. Demographic variables and higher activity levels were not associated with shoulder pain onset. Baseline maximal isometric torque (normalized by body weight) in all shoulder muscle groups was 10% to 15% lower in participants who developed shoulder pain compared with those who remained pain-free. Lower shoulder adduction torque was a significant predictor of shoulder pain development (log-likelihood test=11.38), but the model explained only 7.5% of shoulder pain onset and consequently is of limited clinical utility. Limitations Time since SCI varied widely among participants, and transfer and raise activity was measured by participant recall. Conclusions Participants who developed shoulder pain had decreased muscle strength, particularly in the shoulder adductors, and lower levels of physical activity prior to the onset of shoulder pain. Neither factor was a strong predictor of shoulder pain onset. PMID:25721123
Raigrodski, Ariel J; Yu, Alika; Chiche, Gerard J; Hochstedler, J L; Mancl, Lloyd A; Mohamed, Shawky E
2012-10-01
In recent years, zirconium dioxide-based partial fixed dental prostheses (FDP) have been suggested as an alternative treatment to traditional metal ceramic FDPs. However, clinical studies evaluating their longevity and related complications are limited. The purpose of this cohort clinical study was to assess the efficacy of zirconium dioxide-based posterior 3-unit FDPs. Twenty 3-unit posterior FDPs (Lava) were placed in 16 participants missing a second premolar or a first molar. All participants met specific inclusion and exclusion criteria and provided informed consent. All teeth were prepared in a standardized manner: occlusal reduction of 1.5 to 2 mm; axial reduction of 1 to 1.5 mm; a 1.0 mm 360-degree rounded shoulder placed 0.5 mm subgingivally on the facial aspect and supragingivally on the lingual aspect on sound tooth structure; and rounded internal line angles. Definitive impressions were made with vinyl polysiloxane impression material. Frameworks were fabricated by using computer-aided design and computer-aided manufacturing (CAD/CAM) technology with a uniform retainer thickness of 0.6 mm and a minimal connector surface area of 9 mm(2). Restorations were luted with resin-modified glass ionomer cement (Rely-X Luting). Participants were recalled at 2 weeks, 6 months, and 12 months, and thereafter, annually for up to 60 months. Clinical fracture measurements, marginal discoloration, marginal adaptation, radiographic proximal recurrent caries, and periapical pathoses were assessed over time by using modified Ryge criteria. The probability distributions of these variables were calculated for the baseline data and for the recall data. An analysis of survival was made by using the Kaplan-Meier method. Eighteen FDPs were clinically evaluated at 5 years and 1 at 48 months. Fifteen were rated Alpha for fracture measurements, and 2 were rated Bravo (minor chipping of veneering porcelain and not requiring restoration replacement). Two were rated Charlie (major chipping of veneering porcelain and requiring restoration replacement). Eighteen FDPs were rated Alpha for marginal integrity, and 1 rated Bravo. All restorations were rated Alpha for marginal discoloration. One participant experienced root fracture after 60 months, while another was treated surgically for a periapical pathosis on an endodontically treated abutment. Zirconium dioxide-based posterior 3-unit FDPs performed well after 5 years of service. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
... activities, including your shoulder joint and your shoulder blade Observe your spine and posture as you stand ... band Isometric shoulder exercises Wall push-ups Shoulder blade (scapular) retraction - no tubing Shoulder blade (scapular) retraction - ...
Finley, Margaret A; Rodgers, Mary M
2004-05-01
Although many wheelchair users report shoulder pain, the prevalence of specific pathologies remains controversial. Rotator cuff impingement, glenohumeral instability, and biceps tendonitis have been stated as the most commonly found pathology. This study investigated the prevalence and identity of shoulder pathology in athletic and nonathletic manual wheelchair users (MWCUs). Fifty-two MWCUs (26 athletes, 26 nonathletes) completed a survey regarding the nature of their injury, sports involvement, history, and presence of current and/or past shoulder pathology. Subjects currently experiencing shoulder pain underwent a clinical examination of both shoulders. Analysis of variance (p
Frozen shoulder and the Big Five personality traits.
Debeer, Philippe; Franssens, Fien; Roosen, Isabelle; Dankaerts, Wim; Claes, Laurence
2014-02-01
In the past, several studies have suggested the existence of a "periarthritic personality" in patients with frozen shoulder. We conducted a study to determine differences in personality traits in patients with primary and secondary frozen shoulders. We prospectively evaluated 118 patients (84 women and 34 men; mean age, 53.8 years; SD 7.56) with a frozen shoulder. Of these patients, 48 had an idiopathic frozen shoulder and 70 had a secondary frozen shoulder. Personality traits were determined by the NEO Five-Factor Inventory (NEO-FFI) scale. This questionnaire measures the 5 major personality traits and is based on the norms determined in a neutral test situation for 2415 controls. Compared with healthy controls, no differences in personality traits were found in patients with primary and secondary frozen shoulder, except for Conscientiousness and Extraversion, for which patients with secondary frozen shoulder scored significantly higher than healthy controls. Patients with primary frozen shoulder scored significantly higher on Openness to Experience than did patients with secondary frozen shoulder; on the other 4 Big Five personality traits, no significant differences were found between patients with primary and secondary frozen shoulder. More specifically, patients with idiopathic frozen shoulder did not score higher on the trait Neuroticism as would be expected from previous publications. Our study results do not indicate that patients with an idiopathic frozen shoulder have a specific personality compared with healthy controls. Only a few differences were found in personality traits when the entire frozen shoulder group was compared with healthy controls and between patients with primary and secondary frozen shoulders. The results of this study suggest that these differences are not sufficient to speak about a specific "frozen shoulder personality." Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Mornieux, Guillaume; Hirschmüller, Anja; Gollhofer, Albert; Südkamp, Norbert P; Maier, Dirk
2018-04-01
Functional evaluation of sensorimotor function of the shoulder joint is important for guidance of sports-specific training, prevention and rehabilitation of shoulder instability. Such assessment should be multimodal and comprise all qualities of sensorimotor shoulder function. This study evaluates feasibility of such multimodal assessment of glenohumeral sensorimotor function in patients with shoulder instability and handball players. Nine patients with untreated anterior instability of their dominant shoulder and 15 asymptomatic recreational handball players performed proprioceptive joint position sense and dynamic stabilization evaluations on an isokinetic device, as well as a functional throwing performance task. Outcome measures were analysed individually and equally weighted in a Shoulder-Specific Sensorimotor Index (S-SMI). Finally, isokinetic strength evaluations were conducted. We observed comparable sensorimotor functions of unstable dominant shoulders compared to healthy, contralateral shoulders (e.g. P=0.59 for S-SMI). Handball players demonstrated superior sensorimotor function of their dominant shoulders exhibiting a significantly higher throwing performance and S-SMI (P<0.001 and P=0.002, respectively), but comparable internal rotator peak torques for both shoulders (P>0.22). The present study proves feasibility of multimodal assessment of shoulder sensorimotor function in overhead athletes and patients with symptomatic anterior shoulder instability. Untreated shoulder instability led to a loss of dominance-related sensorimotor superiority indicating functional internal rotation deficiency. Dominant shoulders of handball players showed a superior overall sensorimotor function but weakness of dominant internal rotation constituting a risk factor for occurrence of posterior superior impingement syndrome. The S-SMI could serve as a diagnostic tool for guidance of sports-specific training, prevention and rehabilitation of shoulder instability.
Booker, Simon; Alfahad, Nawaf; Scott, Martin; Gooding, Ben; Wallace, W Angus
2015-01-01
To investigate shoulder scoring systems used in Europe and North America and how outcomes might be classified after shoulder joint replacement. All research papers published in four major journals in 2012 and 2013 were reviewed for the shoulder scoring systems used in their published papers. A method of identifying how outcomes after shoulder arthroplasty might be used to categorize patients into fair, good, very good and excellent outcomes was explored using the outcome evaluations from patients treated in our own unit. A total of 174 research articles that were published in the four journals used some form of shoulder scoring system. The outcome from shoulder arthroplasty in our unit has been evaluated using the constant score (CS) and the oxford shoulder score and these scores have been used to evaluate individual patient outcomes. CSs of < 30 = unsatisfactory; 30-39 = fair; 40-59 = good; 60-69 = very good; and 70 and over = excellent. The most popular shoulder scoring systems in North America were Simple Shoulder Test and American shoulder and elbow surgeons standard shoulder assessment form score and in Europe CS, Oxford Shoulder Score and DASH score. PMID:25793164
Tracheostomy cannulas and voice prosthesis
Kramp, Burkhard; Dommerich, Steffen
2011-01-01
Cannulas and voice prostheses are mechanical aids for patients who had to undergo tracheotomy or laryngectomy for different reasons. For better understanding of the function of those artificial devices, first the indications and particularities of the previous surgical intervention are described in the context of this review. Despite the established procedure of percutaneous dilatation tracheotomy e.g. in intensive care units, the application of epithelised tracheostomas has its own position, especially when airway obstruction is persistent (e.g. caused by traumata, inflammations, or tumors) and a longer artificial ventilation or special care of the patient are required. In order to keep the airways open after tracheotomy, tracheostomy cannulas of different materials with different functions are available. For each patient the most appropriate type of cannula must be found. Voice prostheses are meanwhile the device of choice for rapid and efficient voice rehabilitation after laryngectomy. Individual sizes and materials allow adaptation of the voice prostheses to the individual anatomical situation of the patients. The combined application of voice prostheses with HME (Head and Moisture Exchanger) allows a good vocal as well as pulmonary rehabilitation. Precondition for efficient voice prosthesis is the observation of certain surgical principles during laryngectomy. The duration of the prosthesis mainly depends on material properties and biofilms, mostly consisting of funguses and bacteries. The quality of voice with valve prosthesis is clearly superior to esophagus prosthesis or electro-laryngeal voice. Whenever possible, tracheostoma valves for free-hand speech should be applied. Physicians taking care of patients with speech prostheses after laryngectomy should know exactly what to do in case the device fails or gets lost. PMID:22073098
Kobayashi, Toshiki; Arabian, Adam K.; Orendurff, Michael S.; Rosenbaum-Chou, Teri G.; Boone, David A.
2014-01-01
Background Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet. Methods A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5mm, 10mm and 15mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment. Findings Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the moment at 30% and 75% of stance for all comparisons. Interpretation The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses. PMID:24315709
In vivo implant fixation of carbon fiber-reinforced PEEK hip prostheses in an ovine model.
Nakahara, Ichiro; Takao, Masaki; Bandoh, Shunichi; Bertollo, Nicky; Walsh, William R; Sugano, Nobuhiko
2013-03-01
Carbon fiber-reinforced polyetheretherketone (CFR/PEEK) is theoretically suitable as a material for use in hip prostheses, offering excellent biocompatibility, mechanical properties, and the absence of metal ions. To evaluate in vivo fixation methods of CFR/PEEK hip prostheses in bone, we examined radiographic and histological results for cementless or cemented CFR/PEEK hip prostheses in an ovine model with implantation up to 52 weeks. CFR/PEEK cups and stems with rough-textured surfaces plus hydroxyapatite (HA) coatings for cementless fixation and CFR/PEEK cups and stems without HA coating for cement fixation were manufactured based on ovine computed tomography (CT) data. Unilateral total hip arthroplasty was performed using cementless or cemented CFR/PEEK hip prostheses. Five cementless cups and stems and six cemented cups and stems were evaluated. On the femoral side, all cementless stems demonstrated bony ongrowth fixation and all cemented stems demonstrated stable fixation without any gaps at both the bone-cement and cement-stem interfaces. All cementless cases and four of the six cemented cases showed minimal stress shielding. On the acetabular side, two of the five cementless cups demonstrated bony ongrowth fixation. Our results suggest that both cementless and cemented CFR/PEEK stems work well for fixation. Cup fixation may be difficult for both cementless and cemented types in this ovine model, but bone ongrowth fixation on the cup was first seen in two cementless cases. Cementless fixation can be achieved using HA-coated CFR/PEEK implants, even under load-bearing conditions. Copyright © 2012 Orthopaedic Research Society.
Maló, Paulo; Nobre, Miguel de Araújo; Lopes, Armando; Ferro, Ana; Gravito, Inês
2014-01-01
To report the 5-year outcome of immediately loaded dental implants in patients with untreated periodontal disease. This prospective cohort study included 103 consecutive patients (51 females and 52 males) with an average age of 52 years (range: 22 to 80 years) who were rehabilitated with 380 implants supporting 145 prostheses in both jaws (40 single; 33 partial and 72 complete rehabilitations). The implants were inserted in patients with active and untreated periodontitis. The patients did not receive any previous periodontal treatment before implant surgery, except for an oral hygiene session immediately before the implant surgery. In maintenance (every 6 months) patients received periodontal treatment as needed. Outcome measures were: prostheses failures; implant failures; complications; and marginal bone level changes. Fifteen patients dropped out of the study (14.6%). Two patients lost two implants (FDI positions nos.12 and 42), rendering a cumulative survival rate of 97.9% and 99.4% at 5 years of followup using the patient and implant as unit of analysis, respectively. The average (standard deviation) marginal bone resorption was 0.71 mm (0.42 mm) at 5 years. Mechanical complications occurred in 14 patients, consisting of prostheses fractures (10 provisional prostheses and 4 definitive prostheses). Thirteen implants (3.9%) in 13 patients (14.8%) presented peri-implant pathology. Within the limitations of this study, it is possible to conclude that the rehabilitation of patients with untreated periodontitis using immediately loaded dental implants is feasible in the medium-term, when periodontal therapy is provided after rehabilitation and the patients are regularly maintained.
Minoda, Yukihide; Hata, Kanako; Ikebuchi, Mitsuhiko; Mizokawa, Shigekazu; Ohta, Yoichi; Nakamura, Hiroaki
2017-09-01
Polyethylene wear particle generation is one of the most important factors that affects the mid- to long-term results of total knee arthroplasties (TKA). Mobile-bearing total knee prostheses were developed to reduce polyethylene wear generation. However, whether mobile-bearing prostheses actually generate fewer polyethylene wear particles than fixed-bearing prostheses remains controversial. The aim of this study was to compare, within individual patients, the in vivo polyethylene wear particles created by a newly introduced mobile-bearing prosthesis in one knee and a conventional fixed-bearing prosthesis in other knee. Eighteen patients receiving bilateral TKAs to treat osteoarthritis were included. The synovial fluid was obtained from 36 knees at an average of 3.5 years after the operation. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined using a scanning electron microscope and an image analyser. The size and shape of the polyethylene wear particles from the mobile-bearing prostheses were similar to those from the conventional fixed-bearing prostheses. Although the number of wear particles from the mobile-bearing prosthesis (1.63 × 10 7 counts/knee) appeared smaller than that from the fixed-bearing prosthesis (2.16 × 10 7 counts/knee), the difference was not statistically significant. The current in vivo study shows that no statistically significant differences were found between the polyethylene wear particles generated by a newly introduced mobile-bearing PS prosthesis and a conventional fixed-bearing PS prosthesis during the early clinical stage after implantation. Therapeutic study, Level III.
NASA Astrophysics Data System (ADS)
Todor, Raluca; Negrutiu, Meda-Lavinia; Sinescu, Cosmin; Topala, Florin Ionel; Bradu, Adrian; Duma, Virgil-Florin; Romînu, Mihai; Podoleanu, Adrian G.
2018-03-01
One of the most common fabrication techniques for dental ceramics is sintering, a process of heating of the ceramic to ensure densification. This occurs by viscous flow when the firing temperature is reached. Acceptable restorations require the alloy and ceramic to be chemically, thermally, mechanically, and aesthetically compatible. Thermal and mechanical compatibility include a fusing temperature of ceramic that does not cause distortion of the metal substructure. Decalibration of ovens used for firing of the ceramic layers for metal ceramic dental prostheses leads to stress and cracks in the veneering material, and ultimately to the failure of the restoration. 25 metal ceramic prostheses were made for this study. They were divided in five groups, each sintered at a different temperature: a group at the temperature prescribed by the producer, two groups at lower and two groups at higher temperatures set in the ceramic oven. An established noninvasive biomedical imaging method, swept source (SS) optical coherence tomography (OCT) was employed, in order to evaluate the modifications induced when using temperatures different from those prescribed for firing the samples. A quantitative assessment of the probes is performed by en-face OCT images, taken at constant depths inside the samples. The differences in granulation, thus in reflectivity allow for extracting rules-of-thumb to evaluate fast, by using only the prostheses currently produced the current calibration of the ceramic oven. OCT imaging can allow quick identification of the oven decalibration, to avoid producing dental prostheses with defects.
Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue
2018-05-01
Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.
Travancas, Paulo R; Dorigo, Ana H; Simões, Luiz C; Fonseca, Sandra C; Bloch, Kátia V; Herdy, Gesmar V
2009-04-01
To assess the outcomes in children and adolescents with rheumatic fever of the implantation of mechanical as opposed to biological heart valves. We assessed 73 patients with rheumatic heart disease under the age of 18 years, who underwent replacement of heart valves between January, 1996, and December, 2005, at the National Institute of Cardiology in Rio de Janeiro, Brazil. Of the group, 71 patients survived, and were divided into a group of 52 receiving mechanical prostheses, and 19 with biological prostheses. We compared endpoints between the groups in terms of mortality, reoperation, haemorrhage, and stroke. Survival curves were estimated using the Kaplan-Meier method and were compared by the Mantel (log-rank) test. Overall mortality was 8.2%. In those receiving mechanical prostheses, 2 (3.8%) patients died, 5 (9.6%) underwent reoperation, 2 (3.8%) suffered severe haemorrhage, and 3 (5.8%) had strokes. In those receiving biological valves, 2 (10.5%) patients died, and 4 (21%) underwent reoperation. After 2, 4, and 8 years, overall survival was 96%, 93% and 86%, respectively, with a borderline difference between the groups (p = 0.06). The probabilities of remaining free from reoperation (p = 0.13), and from combined endpoints, showed no statistically significant difference between the groups (p = 0.28). Patients with mechanical prostheses had lower mortality and required fewer reoperations, but when all combined endpoints were considered, the groups did not differ. The biological prosthesis proved to be a good option for cardiac surgery in children and adolescents with difficulties or risks of anticoagulation.
PERSPECTIVE: Is acuity enough? Other considerations in clinical investigations of visual prostheses
NASA Astrophysics Data System (ADS)
Lepri, Bernard P.
2009-06-01
Visual impairing eye diseases are the major frontier facing ophthalmic research today in light of our rapidly aging population. The visual skills necessary for improving the quality of daily function and life are inextricably linked to these impairing diseases. Both research and reimbursement programs are emphasizing outcome-based results. Is improvement in visual acuity alone enough to improve the function and quality of life of visually impaired persons? This perspective summarizes the types of effectiveness endpoints for clinical investigations of visual prostheses that go beyond visual acuity. The clinical investigation of visual prostheses should include visual function, functional vision and quality of life measures. Specifically, they encompass contrast sensitivity, orientation and mobility, activities of daily living and quality of life assessments. The perspective focuses on the design of clinical trials for visual prostheses and the methods of determining effectiveness above and beyond visual acuity that will yield outcomes that are measured by improved function in the visual world and quality of life. The visually impaired population is the primary consideration in this presentation with particular emphases on retinitis pigmentosa and age-related macular degeneration. Clinical trials for visual prostheses cannot be isolated from the need for medical rehabilitation in order to obtain measurements of effectiveness that produce outcomes/evidence-based success. This approach will facilitate improvement in daily function and quality of life of patients with diseases that cause chronic vision impairment. The views and opinions are those of the author and do not necessarily reflect those of the US Food and Drug Administration, the US Department of Health and Human Services or the Public Health Service.
Aschoff, H-H; Juhnke, D-L
2016-05-01
In 1999 the first endo-exo femoral prosthesis (EEFP) was implanted in Germany in a patient who had suffered a traumatic above-knee amputation. This procedure involves a skeletally anchored exoprosthetic device that is inserted into the residual femur. The distal part of the implant protrudes transcutaneously and allows attachment to a prosthetic limb which provides direct force transmission to the external prosthetic components. The technique originated from dental implantology and helps to avoid possible problems resulting from treatment of amputated limbs using socket prostheses. In the meantime, durability times of over 10 years have now helped to invalidate the initially well-founded reservations held against the procedure. What advantages can be achieved by osseointegrated and percutaneously channeled prostheses and which problems had to be overcome for treatment. Critical evaluation of data from patients operated on in Lübeck, Germany from January 2003 to December 2014. With osseointegrated and percutaneously channeled prostheses permanent durability times can be achieved. Infection-associated soft tissue problems at the site of skin protrusion (stoma) can be successfully prevented. The creation of this so-called stoma means acceptance of a possible bacterial portal of entry into the body. Patient satisfaction has so far been high, postoperative rehabilitation is simplified and the technique could possibly lower the costs of medical treatment. Endo-exo prostheses have proved to be successful for more than 15 years. A critical appraisal of the indications as well as a close cooperation between the surgeon, orthopedic technician and the associated rehabilitation facilities with the patient are the basis for the long-term success of this relatively new treatment approach.
Effect of prosthesis endplate lordosis angles on L5-S1 kinematics after disc arthroplasty.
Tsitsopoulos, Parmenion P; Wojewnik, Bartosz; Voronov, Leonard I; Havey, Robert M; Renner, Susan M; Zelenakova, Julia; McIntosh, Braden; Carandang, Gerard; Abjornson, Celeste; Patwardhan, Avinash G
2012-06-01
We hypothesized that L5-S1 kinematics will not be affected by the lordosis distribution between the prosthesis endplates. Twelve cadaveric lumbosacral spines (51.3 ± 9.8 years) were implanted with 6° or 11° prostheses (ProDisc-L) with four combinations of superior/inferior lordosis (6°/0°, 3°/3°, 11°/0°, 3°/8°). Specimens were tested intact and after prostheses implantation with different lordosis distributions. Center of rotation (COR) and range of motion (ROM) were quantified. Six-degree lordosis prostheses (n = 7) showed no difference in flexion-extension ROM, regardless of design (6°/0° or 3°/3°) (p > 0.05). In lateral bending (LB), both designs reduced ROM (p < 0.05). In axial rotation, only the 3°/3° design reduced ROM (p < 0.05). Eleven-degree lordosis prostheses (n = 5) showed no difference in flexion-extension ROM for either design (p > 0.05). LB ROM decreased with distributed lordosis prostheses (3°/8°) (p < 0.05). Overall, L5-S1 range of motion was not markedly influenced by lordosis distribution among the two prosthesis endplates. The ProDisc-L prosthesis design where all lordosis is concentrated in the superior endplate yielded COR locations that were anterior and caudal to intact controls. The prosthesis with lordosis distributed between the two endplates yielded a COR that tended to be closer to intact. Further clinical and biomechanical studies are needed to assess the long-term impact of lordosis angle distribution on the fate of the facet joints.
Zanolla, Jaine; Amado, Flávio Monteiro; da Silva, Willian Saranholi; Ayub, Bruno; de Almeida, Ana Lúcia Pompéia Fraga; Soares, Simone
2016-01-01
Background: The prosthetic treatment in cleft patients is challenging. Based on this, the aim of this study was to evaluate the longevity of prosthetic rehabilitation treatment with implant-supported overdenture (IOD) and implant-supported fixed denture (IFD) in cleft lip and palate patients in a period of 22 years. Materials and Methods: The medical records of 72 patients were analyzed (29 males and 43 females), and the survival rate of the implants was evaluated. Moreover, the prostheses’ time of use and the reason for the changing of these were also evaluated. Results: Four-hundred-seventeen implants were installed, and 370 implants survive today. The mean survival time of the implants was 7.6 years. Regarding the 97 prostheses made, the time of average use was 3.28 for the IFDs and 3.92 for IODs. The reasons for the replacements of the prostheses were mainly: fracture of the acrylic base (29.6%) and loss of vertical dimension of occlusion (VDO) (18.5%) in the IFDs. Moreover, in IODs, these were accounted for the loss of VDO due to teeth damage (17.2%) and implant loss (14.6%). Conclusions: The maintenance of the prostheses was challenging because the patients had difficulties returning for periodic control, but this fact did not result in the decrease of the success rate of the implants. The longevity of implants and prostheses was satisfactory; however, the prostheses showed repetitions mainly due to the wear of the teeth, with decreased vertical dimension and fracture of acrylic base. PMID:28299262
Tracheostomy cannulas and voice prosthesis.
Kramp, Burkhard; Dommerich, Steffen
2009-01-01
Cannulas and voice prostheses are mechanical aids for patients who had to undergo tracheotomy or laryngectomy for different reasons. For better understanding of the function of those artificial devices, first the indications and particularities of the previous surgical intervention are described in the context of this review. Despite the established procedure of percutaneous dilatation tracheotomy e.g. in intensive care units, the application of epithelised tracheostomas has its own position, especially when airway obstruction is persistent (e.g. caused by traumata, inflammations, or tumors) and a longer artificial ventilation or special care of the patient are required. In order to keep the airways open after tracheotomy, tracheostomy cannulas of different materials with different functions are available. For each patient the most appropriate type of cannula must be found. Voice prostheses are meanwhile the device of choice for rapid and efficient voice rehabilitation after laryngectomy. Individual sizes and materials allow adaptation of the voice prostheses to the individual anatomical situation of the patients. The combined application of voice prostheses with HME (Head and Moisture Exchanger) allows a good vocal as well as pulmonary rehabilitation. Precondition for efficient voice prosthesis is the observation of certain surgical principles during laryngectomy. The duration of the prosthesis mainly depends on material properties and biofilms, mostly consisting of funguses and bacteries. The quality of voice with valve prosthesis is clearly superior to esophagus prosthesis or electro-laryngeal voice. Whenever possible, tracheostoma valves for free-hand speech should be applied. Physicians taking care of patients with speech prostheses after laryngectomy should know exactly what to do in case the device fails or gets lost.
Magnetic resonance imaging in glenohumeral instability
Jana, Manisha; Gamanagatti, Shivanand
2011-01-01
The glenohumeral joint is the most commonly dislocated joint of the body and anterior instability is the most common type of shoulder instability. Magnetic resonance (MR) imaging, and more recently, MR arthrography, have become the essential investigation modalities of glenohumeral instability, especially for pre-procedure evaluation before arthroscopic surgery. Injuries associated with glenohumeral instability are variable, and can involve the bones, the labor-ligamentous components, or the rotator cuff. Anterior instability is associated with injuries of the anterior labrum and the anterior band of the inferior glenohumeral ligament, in the form of Bankart lesion and its variants; whereas posterior instability is associated with reverse Bankart and reverse Hill-Sachs lesion. Multidirectional instability often has no labral pathology on imaging but shows specific osseous changes such as increased chondrolabral retroversion. This article reviews the relevant anatomy in brief, the MR imaging technique and the arthrographic technique, and describes the MR findings in each type of instability as well as common imaging pitfalls. PMID:22007285
[Computer aided design for fixed partial denture framework based on reverse engineering technology].
Sun, Yu-chun; Lü, Pei-jun; Wang, Yong
2006-03-01
To explore a computer aided design (CAD) route for the framework of domestic fixed partial denture (FPD) and confirm the suitable method of 3-D CAD. The working area of a dentition model was scanned with a 3-D mechanical scanner. Using the reverse engineering (RE) software, margin and border curves were extracted and several reference curves were created to ensure the dimension and location of pontic framework that was taken from the standard database. The shoulder parts of the retainers were created after axial surfaces constructed. The connecting areas, axial line and curving surface of the framework connector were finally created. The framework of a three-unit FPD was designed with RE technology, which showed smooth surfaces and continuous contours. The design route is practical. The result of this study is significant in theory and practice, which will provide a reference for establishing the computer aided design/computer aided manufacture (CAD/CAM) system of domestic FPD.
Laslett, L L; Burnet, S P; Jones, J A; Redmond, C L; McNeil, J D
2007-01-01
To investigate shoulder pain and disability and quality of life (QoL) over 12 months in patients with diabetes and in a non-diabetic control group. Cross-sectional study with 12-month follow-up in diabetic (n=189) and medical (n=99) outpatients employing the Shoulder Pain and Disability Index (SPADI) and SF-36 version 2. The results were analysed using restricted maximum likelihood (REML). The prevalence of current shoulder symptoms was 35% in diabetics and 17% in controls. Shoulder pain and disability as calculated by the SPADI were independently associated with diabetes (vs controls) and current shoulder symptoms, and worsened over 12 months. Disability scores worsened with age in diabetics, and pain scores were higher in diabetics than controls among patients reporting current shoulder symptoms. Poor physical QoL worsened over time in patients with diabetes and was worse in patients with current shoulder symptoms, whether they had diabetes or not. Mental QoL was worse only in patients with current shoulder symptoms. Shoulder symptoms are common, affecting 1 in every 3 diabetic patients and 1 in every 6 control patients. In this study shoulder pain, disability and physical QoL were poorer among diabetics and patients reporting current shoulder symptoms, and worsened over time. Mental QoL was worse in patients reporting current shoulder symptoms and was independent of diabetes. Therefore, shoulder symptoms are common, are associated with poor physical and mental QoL in addition to shoulder pain and disability, and are worse in patients with diabetes, even in a population with relatively moderate shoulder pain and disability.
Composite Materials for Maxillofacial Prostheses.
1982-11-01
1(AXILLOFACIAL PROSTHESES; PROSTHETIC MATERIALS: MICROCAPSULES : SOFT FILLERS; ELASTOMER COMPOSITES *ASTRAC7 lCofIflU Ir F*vsda Side It neceOaeen anud...composite systems are elastomeric-shelled, liquid-filled microcapsules . Experiments continued on the interfacial polymerization process, with spherical...sealed, capsules achieved. The diamine bath has been E] improved and an automatic system has been developed for producing the microcapsules . The one
Visual Prostheses: The Enabling Technology to Give Sight to the Blind
Maghami, Mohammad Hossein; Sodagar, Amir Masoud; Lashay, Alireza; Riazi-Esfahani, Hamid; Riazi-Esfahani, Mohammad
2014-01-01
Millions of patients are either slowly losing their vision or are already blind due to retinal degenerative diseases such as retinitis pigmentosa (RP) and age-related macular degeneration (AMD) or because of accidents or injuries. Employment of artificial means to treat extreme vision impairment has come closer to reality during the past few decades. Currently, many research groups work towards effective solutions to restore a rudimentary sense of vision to the blind. Aside from the efforts being put on replacing damaged parts of the retina by engineered living tissues or microfabricated photoreceptor arrays, implantable electronic microsystems, referred to as visual prostheses, are also sought as promising solutions to restore vision. From a functional point of view, visual prostheses receive image information from the outside world and deliver them to the natural visual system, enabling the subject to receive a meaningful perception of the image. This paper provides an overview of technical design aspects and clinical test results of visual prostheses, highlights past and recent progress in realizing chronic high-resolution visual implants as well as some technical challenges confronted when trying to enhance the functional quality of such devices. PMID:25709777
Accelerated treatment protocols: full arch treatment with interim and definitive prostheses.
Drago, Carl
2012-01-01
With the advent of titanium, root form implants and osseointegration, dental treatment has undergone a metamorphosis in recent years. These new techniques enable dentists to provide anchorage for various kinds of prostheses that improve masticatory function, esthetics, and comfort for patients. Implant treatment protocols have been improved relative to implant macro- and micro-geometries, surgical and prosthetic components, and treatment times. Over the past 20 years, immediate occlusal function (also known as loading) has been established as a predictable treatment modality, provided certain specific criteria are met. In many cases, edentulous patients, crippled by the loss of their teeth, can undergo outpatient surgical and prosthetic procedures and return to a masticatory function that is near normal--sometimes after only one day of surgical and prosthetic treatment. This treatment option is also available for patients with advanced, generalized periodontal disease. Computer-assisted design/Computer-assisted manufacturing (CAD/CAM) has transformed how dental prostheses are made, offering improved accuracy, longevity, and biocompatibility; along with reduced labor costs and fewer complications than casting technologies. This article reviews the principles associated with immediate occlusal loading and illustrates one specific accelerated prosthodontic treatment protocol used to treat edentulous and partially edentulous patients with interim and definitive prostheses.
Anitua, Eduardo; Flores, Carlos; Piñas, Laura; Alkhraisat, Mohammad
2018-06-05
CAD-CAM technology permits the angular correction of screw emergence into the prosthesis, however there is lack of controlled clinical studies that assess the frequency of technical complications in angled screw channel restorations. This controlled clinical study was designed to assess technical incidences in angled screw channel restorations. Patients having implant prosthesis placed between November, 2014 and December, 2015 were screened. The patients were selected if they received prosthesis with up to 30º correction of the prosthesis screw emergence and had at least one non-angulated prosthesis (screw-retained). All the prostheses were located completely/partially in the posterior region. The frequency of technical complications was the principal variable. A total of 52 patients with a mean age of 62 ± 10 years participated with a total 110 prostheses (55 in the test group and 55 in the control group). A total of 11 technical complications occurred (7 in the test group and 4 in the control group). These differences were not statistically significant. All the prostheses in both groups survived the follow-up. The correction of the screw emergence into the prosthesis has not increased the risk of technical complications in CAD-CAM implant prostheses.
PARTICIPATORY DESIGN OF PEDIATRIC UPPER LIMB PROSTHESES: QUALITATIVE METHODS AND PROTOTYPING.
Sims, Tara; Cranny, Andy; Metcalf, Cheryl; Chappell, Paul; Donovan-Hall, Maggie
2017-01-01
The study aims to develop an understanding of the views of children and adolescents, parents, and professionals on upper limb prosthetic devices to develop and improve device design. Previous research has found that children are dissatisfied with prostheses but has relied heavily on parent proxy reports and quantitative measures (such as questionnaires) to explore their views. Thirty-four participants (eight children aged 8-15 years with upper limb difference, nine parents, eight prosthetists, and nine occupational therapists) contributed to the development of new devices through the BRIDGE methodology of participatory design, using focus groups and interviews. The study identified areas for improving prostheses from the perspective of children and adolescents, developed prototypes based on these and gained feedback on the prototypes from the children and other stakeholders (parents and professionals) of paediatric upper limb prostheses. Future device development needs to focus on ease of use, versatility, appearance, and safety. This study has demonstrated that children and adolescents can and should be involved as equal partners in the development of daily living equipment and that rapid prototyping (three-dimensional printing or additive manufacturing), used within a participatory design framework, can be a useful tool for facilitating this.
Improvement on upper limb body-powered prostheses (1921-2016): A systematic review.
Hashim, Nur Afiqah; Abd Razak, Nasrul Anuar; Abu Osman, Noor Azuan; Gholizadeh, Hossein
2018-01-01
Body-powered prostheses are known for their advantages of cost, reliability, training period, maintenance, and proprioceptive feedback. This study primarily aims to analyze the work related to the improvement of upper limb body-powered prostheses prior to 2016. A systematic review conducted via the search of the Web of Science electronic database, Google Scholar, and Google Patents identified 155 papers from 1921 to 2016. Sackett's initial rules of evidence were used to determine the levels of evidence, and only papers categorized in the design and development category and patents were analyzed. A total of 40 papers in the sixth level of "Design and Development" of an upper limb body-powered prosthesis were found. Approximately 81% were categorized under mechanical alteration. Most papers were patent-type documents (48%), with the Journal of Rehabilitation Research and Development publishing most of the articles related to the design and development of body-powered prostheses. Papers in the scope of the study were published once every 3 years in almost a century, proving that only a few studies were conducted to improve body-powered arms compared with myoelectric technology. Further research should be carried out mainly in areas that have received less attention.
Safety of MRI with metallic middle ear implants.
Tohme, Souheil M; Karkas, Alexandre A; Romanos, Bassam H
2003-01-01
Investigation of the effects of magnetic resonance fields on commonly used metallic middle ear implants. Nine middle ear prostheses (seven containing stainless steel and two made of pure gold used as control) were tested in vitro and one stainless steel stapedectomy prosthesis was tested on a cadaveric temporal bone. Each metallic prosthesis was placed in an empty Petri dish and introduced into a 1.5-tesla (T) magnetic resonance imaging (MRI) unit. Most of the prostheses were then placed in a water-filled Petri dish and reintroduced into the MRI unit. Eventual in vitro displacement was assessed visually by two means. In situ testing was done by implanting a piston in a cadaveric temporal bone and performing MR sequences ; any possible displacement was then assessed by CT scan and under microscopic vision. None of the prostheses was displaced in the empty Petri dish. However, while in the water-filled Petri dish, three of these moved with the flux. The implanted piston in the temporal bone did not move. The displacement of three of the prostheses in water is not relevant in real clinical situations. MRI can thus be considered safe in usual clinical settings, as far as our studied implants are concerned.
Safety of magnetic resonance imaging of stapes prostheses.
Syms, Mark James
2005-03-01
Assess the safety of performing magnetic resonance imaging (MRI) on patients with stapes prostheses. Survey and animal model. A survey regarding implant usage, MRI procedures, and adverse outcomes after MRI in patients previously undergoing stapes procedures. Guinea pigs implanted with ferromagnetic 17 to 4 stainless steel, 316L nonferromagnetic stainless steel, titanium, and fluoroplastic stapes prostheses underwent a MRI in a 4.7 Tesla MR system. : Three adverse outcomes were reported on the clinical survey. One adverse event occurred during an MRI performed on a recalled ferromagnetic prosthesis. The other two adverse events were probably not secondary to MRI exposure. No damage or inflammation was observed in the region of the oval window or vestibule of implanted guinea pigs exposed to a 4.7 Tesla MR system. The combination of prior studies, the clinical survey, and the absence of histopathologic evidence of damage in the guinea pigs is compelling evidence that MRI for patients with stapes prostheses is safe. Implanting physicians should feel comfortable clearing a patient for a MRI in a 1.5 Tesla or 3.0 Tesla MRI. It is imperative for the physician to qualify the field strength when clearing a patient to undergo a MRI.
Recurrent shoulder dystocia: is it predictable?
Kleitman, Vered; Feldman, Roi; Walfisch, Asnat; Toledano, Ronen; Sheiner, Eyal
2016-11-01
To examine the course and outcome of deliveries occurring in women who previously experienced shoulder dystocia. In addition, recurrent shoulder dystocia risk factors were assessed. A retrospective cohort analysis comparing all singleton deliveries with and without shoulder dystocia in their preceding delivery was conducted. Independent predictors of recurrent shoulder dystocia were investigated using a multiple logistic regression model. Of the 201,422 deliveries included in the analysis, 307 occurred in women with a previous shoulder dystocia (0.015 %). Women with a history of shoulder dystocia were more likely to be older, experienced higher rates of gestational diabetes mellitus, polyhydramnios, prolonged second stage, operative delivery and macrosomia (>4000 g) in the following delivery. Previous shoulder dystocia was found to be an independent risk factor for recurrent shoulder dystocia (OR = 6.1, 95 % CI 3.2-11.8, p value <0.001) in the multivariable regression analysis. Shoulder dystocia is an independent risk factor for recurrent shoulder dystocia. Deliveries in women with a history of shoulder dystocia are characterized by higher rates of operative delivery, prolonged second stage of labor and macrosomia.
CAT scan - shoulder; Computed axial tomography scan - shoulder; Computed tomography scan - shoulder; CT scan - shoulder ... Risks of CT scans include: Being exposed to radiation Allergic reaction to contrast dye Birth defect if done during pregnancy CT scans ...
Clinical Evaluation of the TITAN™ Total Shoulder System
2018-02-14
Arthritis; Arthritis, Degenerative; Rheumatoid Arthritis; Post-traumatic Arthrosis of Other Joints, Shoulder Region; Rotator Cuff Syndrome of Shoulder and Allied Disorders; Fracture; Avascular Necrosis; Joint Instability; Joint Trauma; Dislocation, Shoulder; Pain, Shoulder
Sorensen, Christopher J; Hastings, Mary K; Lang, Catherine E; McGill, Janet B; Clark, B Ruth; Bohnert, Kathryn L; Mueller, Michael J
2017-06-01
People with type 2 diabetes (T2DM) have a high incidence of musculoskeletal disorders thought to be influenced by high non-enzymatic advanced glycated end-products (AGEs). The goals of this study were to determine differences in shoulder activity level and AGEs in people with T2DM compared to matched controls, and to determine factors associated with shoulder pain and disability. Eighty-one participants, T2DM (n=52) and controls (n=29), were examined for magnitude and duration of shoulder activity (measured using accelerometers), skin intrinsic florescence (SIF) as a surrogate measure of AGE level, and the Shoulder Pain and Disability Index (SPADI) as a self-report of shoulder pain and disability. Compared with controls, T2DM participants had 23% less shoulder activity (p=0.01), greater SIF level (3.6±1.7 vs 2.7±0.6AU, p=0.01), less shoulder strength (p<0.05), and the duration of their shoulder activity was moderately associated (r=0.40; p<0.01) with reported shoulder pain and disability. Shoulder pain and disability were not related to SIF level. Persons with T2DM have higher SIF levels and shoulder symptoms and disability indices than controls. Research is needed to determine if a shoulder mobility intervention to increase strength and mobility can help decrease shoulder pain and disability. Copyright © 2017 Elsevier Inc. All rights reserved.
Sorensen, Christopher J.; Hastings, Mary K.; Lang, Catherine E.; McGill, Janet B.; Clark, B. Ruth; Bohnert, Kathryn L.; Mueller, Michael J.
2017-01-01
Aim People with type 2 diabetes (T2DM) have a high incidence of musculoskeletal disorders thought to be influenced by high non-enzymatic advanced glycated end-products (AGEs). The goals of this study were to determine differences in shoulder activity level and AGEs in people with T2DM compared to matched controls, and to determine factors associated with shoulder pain and disability. METHODS Eighty-one participants, T2DM (n=52) and controls (n=29), were examined for magnitude and duration of shoulder activity (measured using accelerometers), skin intrinsic florescence (SIF) as a surrogate measure of AGE level, and the Shoulder Pain and Disability Index (SPADI) as a self-report of shoulder pain and disability. RESULTS Compared with controls, T2DM participants had 23% less shoulder activity (p=0.01), greater SIF level (3.6 ± 1.7 vs 2.7 ± 0.6 AU, p=0.01), less shoulder strength (p<0.05), and the duration of their shoulder activity was moderately associated (r = 0.40; p<0.01) with reported shoulder pain and disability. Shoulder pain and disability were not related to SIF level. CONCLUSIONS Persons with T2DM have higher SIF levels and shoulder symptoms and disability indices than controls. Research is needed to determine if a shoulder mobility intervention to increase strength and mobility can help decrease shoulder pain and disability. PMID:28392042
Van Straaten, Meegan G.; Cloud, Beth A.; Zhao, Kristin D.; Fortune, Emma; Morrow, Melissa M. B.
2017-01-01
Shoulder pain from overuse of the arm is common after spinal cord injury (SCI). This pain can be difficult to eliminate. There are many other complications after SCI; therefore, shoulder pain is sometimes not the first priority. However, if neglected for too long, shoulder pain could mean that more serious problems are happening inside the shoulder joint. Here we present the options available when treatment for shoulder pain is needed. PMID:28185640
[Polish vascular prosthesis sealed by albumin].
Raczyński, K; Dyczka, A; Gawlikowska, Z
1992-01-01
TRICOMED, Medical Articles has been conducting its research on textile vascular prostheses for over 35 years. In the seventies, a collagen coated graft was designed and fabricated which, however, after having been positively evaluated ceased to be used by clinics. In the eighties, double velour DALLONR prostheses was introduced which are now marketed by our company. The DALLONR graft has a low mass, developed surface area and moderate porosity. In the eighties, foreign manufacturers launched various types of coated grafts. Responding to that popular market trend we have resumed our early research on the preclotted prostheses and started studies on the use of albumin and chitosan as coating agents. The grafts impregnated with albumin have achieved satisfactory results of biological and experimental testing. These results are confirmed by current clinical examination.
Svendsen, Susanne Wulff; Dalbøge, Annett; Andersen, Johan Hviid; Thomsen, Jane Frølund; Frost, Poul
2013-11-01
The aim of this longitudinal study was to evaluate the risk of surgery for subacromial impingement syndrome (SIS) in relation to neck-shoulder complaints and occupational biomechanical shoulder exposures. The study was based on the Musculoskeletal Research Database at the Danish Ramazzini Centre. We linked baseline questionnaire information from 1993-2004 on neck-shoulder complaints, job titles, psychosocial work factors, body mass index, and smoking with register information on first-time surgery for SIS from 1996-2008. Biomechanical exposure measures were obtained from a job exposure matrix based on expert judgment. We applied multivariable Cox regression. During 280 125 person-years of follow-up among 37 402 persons, 557 first-time operations for SIS occurred. Crude surgery rates increased from 1.1 to 2.5 per 1000 person-years with increasing shoulder load. Using no neck-shoulder complaints and low shoulder load at baseline as a reference, no neck-shoulder complaints and high shoulder load showed an adjusted hazard ratio (HR(adj)) of 2.55 [95% confidence interval (95% CI) 1.59-4.09], while neck-shoulder complaints in combination with high shoulder load showed an HR(adj) of 4.52 (95% CI 2.87-7.13). Subanalyses based on 18 856 persons showed an HR(adj) of 5.40 (95% CI 2.88-10.11) for complaints located specifically in the shoulder in combination with high shoulder load. Based on these findings, persons with neck-shoulder and especially shoulder complaints in combination with high shoulder load seem an obvious target group for interventions aimed at reducing exposures to prevent surgery for SIS.
Chen, Hui-Chun; Chuang, Tai-Yuan; Lin, Pi-Chu; Lin, Yen-Kuang; Chuang, Yeu-Hui
2017-07-01
The aim of this study was to examine the effects of reminders, encouragement, and educational messages delivered by mobile phone on shoulder exercise compliance and improvements in shoulder function among patients with a frozen shoulder. A randomized controlled trial design was used. A convenience sample of patients with a frozen shoulder in an orthopedic outpatient clinic was recruited. All participants were instructed on how to do shoulder exercises and were provided with a printed pamphlet about shoulder exercises. Then, the intervention group received reminders, encouragement, and educational messages by mobile phone daily for the next 2 weeks, while the comparison group did not. The intervention group had higher compliance with shoulder exercises than did the comparison group (t = 2.263, p = .03) and had significant improvements in shoulder forward flexion (F = 12.067, p = .001), external rotation (F = 13.61, p = .001), and internal rotation (F = 5.903, p = .018) compared to those in the comparison group after the 2-week intervention. The text messages significantly increased patient compliance with shoulder exercises and thus improved patients' shoulder range of motion. Hospital or clinics can send appropriate messages to patients via text message platforms in order to remind and encourage them to do shoulder exercises. © 2017 Sigma Theta Tau International.
NASA Astrophysics Data System (ADS)
Iwamoto, Masami; Miki, Kazuo; Yang, King H.
Previous studies in both fields of automotive safety and orthopedic surgery have hypothesized that immobilization of the shoulder caused by the shoulder injury could be related to multiple rib fractures, which are frequently life threatening. Therefore, for more effective occupant protection, it is important to understand the relationship between shoulder injury and multiple rib fractures in side impact. The purpose of this study is to develop a finite element model of the human shoulder in order to understand this relationship. The shoulder model included three bones (the humerus, scapula and clavicle) and major ligaments and muscles around the shoulder. The model also included approaches to represent bone fractures and joint dislocations. The relationships between shoulder injury and immobilization of the shoulder are discussed using model responses for lateral shoulder impact. It is also discussed how the injury can be related to multiple rib fractures.
A comparison of peak power in the shoulder press and shoulder throw.
Dalziel, W M; Neal, R J; Watts, M C
2002-09-01
The ability to generate peak power is central for performance in many sports. Currently two distinct resistance training methods are used to develop peak power, the heavy weight/slow velocity and light weight/fast velocity regimes. When using the light weight/fast velocity power training method it was proposed that peak power would be greater in a shoulder throw exercise compared with a normal shoulder press. Nine males performed three lifts in the shoulder press and shoulder throw at 30% and 40% of their one repetition maximum (1RM). These lifts were performed identically, except for the release of the bar in the throw condition. A potentiometer attached to the bar measured displacement and duration of the lifts. The time of bar release in the shoulder throw was determined with a pressure switch. ANOVA was used to examine statistically significant differences where the level of acceptance was set at p < 0.05. Peak power was found to be significantly greater in the shoulder throw at 30% of 1 RM condition [F, (1, 23) = 2.325 p < 0.051 and at 40% of 1 RM [F, (1, 23) = 2.905 p < 0.05] compared to values recorded for the respective shoulder presses. Peak power was also greater in the 30% of 1 RM shoulder throw (510 +/- 103W) than in the 40% of 1 RM shoulder press (471 +/- 96W). Peak power was produced significantly later in the shoulder throw versus the shoulder press. This differing power reflected a greater bar velocity of the shoulder throw at both assigned weights compared with the shoulder press.
Shoulder injuries in elite rugby union football matches: Epidemiology and mechanisms.
Usman, Juliana; McIntosh, Andrew S; Quarrie, Kenneth; Targett, Stephen
2015-09-01
Shoulder injuries in rugby union football have been the focus of few in-depth studies, despite their frequency and severity. The study's objective was to describe the incidence, patterns and mechanisms of shoulder injuries in rugby. Prospective cohort study of shoulder injury incidence and retrospective case-series study of shoulder injury mechanisms. Data were collected from Super Rugby matches from 2005 to 2010 involving elite level adult male rugby players. 7920 player participation hours and 100 shoulder injuries were recorded during 397 Super Rugby matches. The shoulder injury incidence rate was 13 per 1000 player hours (95% confidence interval 10-16). The mean number of days unavailable for selection due to these injuries was 37 (95% confidence interval 25-54). Tacklers sustained shoulder injuries at a higher rate than ball carriers (Rate Ratio=1.7 (95% confidence interval 0.5-5.3)). The most frequently reported injuries were those to the acromio-clavicular joint; dislocations resulted in the greatest amount of missed play. Using video analysis, 47 of the 100 shoulder injury events were successfully identified and analyzed. The main mechanisms of shoulder injury were contact with the ground with the shoulder/arm in horizontal adduction, flexion, and internal rotation; and impact to the lateral aspect of the shoulder with the elbow flexed and arm at the side. Direct impact to the shoulder, either through player-to-player contact or contact with the ground, is the main cause of shoulder injury. Methods to reduce injury risk, such as shoulder pads and tackle skills, require consideration. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
2011-01-01
Background We herein describe a surgical technique for the repair of complete tear of the pectoralis major (PM) tendon using endobuttons to strengthen initial fixation. Methods Five male patients (3 judo players, 1 martial arts player, and 1 body builder) were treated within 2 weeks of sustaining complete tear of the PM tendon. Average age at surgery and follow-up period were 28.4 years (range, 23-33) and 28.8 months (range, 24-36). A rectangular bone trough (about 1 × 4 cm) was created on the humerus at the insertion of the distal PM tendon. The tendon stump was introduced into this trough, and fixed to the reverse side of the humeral cortex using endobuttons and non-absorbable suture. Clinical assessment of re-tear was examined by MRI. Shoulder range of motion (ROM), outcome of treatment, and isometric power were measured at final follow-up. Results There were no clinical re-tears, and MRI findings also showed continuity of the PM tendon in all cases at final follow-up. Average ROM did not differ significantly between the affected and unaffected shoulders. The clinical outcomes at final follow-up were excellent (4/5 cases) or good (1/5). In addition, postoperative isometric power in horizontal flexion of the affected shoulder showed complete recovery when compared with the unaffected side. Conclusions Satisfactory outcomes could be obtained when surgery using the endobutton technique was performed within 2 weeks after complete tear of the PM tendon. Therefore, our new technique appears promising as a useful method to treat complete tear of the PM tendon. PMID:21955511
Muscular Activation During Plyometric Exercises in 90° of Glenohumeral Joint Abduction
Ellenbecker, Todd S.; Sueyoshi, Tetsuro; Bailie, David S.
2015-01-01
Background: Plyometric exercises are frequently used to increase posterior rotator cuff and periscapular muscle strength and simulate demands and positional stresses in overhead athletes. The purpose of this study was to provide descriptive data on posterior rotator cuff and scapular muscle activation during upper extremity plyometric exercises in 90° of glenohumeral joint abduction. Hypothesis: Levels of muscular activity in the posterior rotator cuff and scapular stabilizers will be high during plyometric shoulder exercises similar to previously reported electromyographic (EMG) levels of shoulder rehabilitation exercises. Study Design: Descriptive laboratory study. Methods: Twenty healthy subjects were tested using surface EMG during the performance of 2 plyometric shoulder exercises: prone external rotation (PERP) and reverse catch external rotation (RCP) using a handheld medicine ball. Electrode application included the upper and lower trapezius (UT and LT, respectively), serratus anterior (SA), infraspinatus (IN), and the middle and posterior deltoid (MD and PD, respectively) muscles. A 10-second interval of repetitive plyometric exercise (PERP) and 3 repetitions of RCP were sampled. Peak and average normalized EMG data were generated. Results: Normalized peak and average IN activity ranged between 73% and 102% and between 28% and 52% during the plyometric exercises, respectively, with peak and average LT activity measured between 79% and 131% and between 31% and 61%. SA activity ranged between 76% and 86% for peak and between 35% and 37% for average activity. Muscular activity levels in the MD and PD ranged between 49% and 72% and between 12% and 33% for peak and average, respectively. Conclusion: Moderate to high levels of muscular activity were measured in the rotator cuff and scapular stabilizers during these plyometric exercises with the glenohumeral joint abducted 90°. PMID:25553216
Muscular activation during plyometric exercises in 90° of glenohumeral joint abduction.
Ellenbecker, Todd S; Sueyoshi, Tetsuro; Bailie, David S
2015-01-01
Plyometric exercises are frequently used to increase posterior rotator cuff and periscapular muscle strength and simulate demands and positional stresses in overhead athletes. The purpose of this study was to provide descriptive data on posterior rotator cuff and scapular muscle activation during upper extremity plyometric exercises in 90° of glenohumeral joint abduction. Levels of muscular activity in the posterior rotator cuff and scapular stabilizers will be high during plyometric shoulder exercises similar to previously reported electromyographic (EMG) levels of shoulder rehabilitation exercises. Descriptive laboratory study. Twenty healthy subjects were tested using surface EMG during the performance of 2 plyometric shoulder exercises: prone external rotation (PERP) and reverse catch external rotation (RCP) using a handheld medicine ball. Electrode application included the upper and lower trapezius (UT and LT, respectively), serratus anterior (SA), infraspinatus (IN), and the middle and posterior deltoid (MD and PD, respectively) muscles. A 10-second interval of repetitive plyometric exercise (PERP) and 3 repetitions of RCP were sampled. Peak and average normalized EMG data were generated. Normalized peak and average IN activity ranged between 73% and 102% and between 28% and 52% during the plyometric exercises, respectively, with peak and average LT activity measured between 79% and 131% and between 31% and 61%. SA activity ranged between 76% and 86% for peak and between 35% and 37% for average activity. Muscular activity levels in the MD and PD ranged between 49% and 72% and between 12% and 33% for peak and average, respectively. Moderate to high levels of muscular activity were measured in the rotator cuff and scapular stabilizers during these plyometric exercises with the glenohumeral joint abducted 90°.
Point-of-care ultrasound facilitates diagnosing a posterior shoulder dislocation.
Mackenzie, David C; Liebmann, Otto
2013-05-01
Posterior shoulder dislocation is an uncommon disruption of the glenohumeral joint. Risk factors include seizure, electric shock, and underlying instabilities of the shoulder joint. A 27-year-old man with a history of recurrent posterior shoulder dislocation presented to the Emergency Department with sudden shoulder pain and reduced range of motion about the shoulder after abducting and internally rotating his arm. Radiographs did not show fracture or dislocation. The treating physician suspected an occult posterior shoulder dislocation, but wanted to avoid performing a computed tomography scan of the shoulder, as the patient had undergone numerous scans during the evaluation of similar complaints. Instead, a point-of-care ultrasound was performed, demonstrating posterior displacement of the humeral head relative to the glenoid rim, confirming the presence of a posterior shoulder dislocation. The patient received procedural sedation, and the shoulder was reduced with real-time ultrasound visualization. The patient tolerated the procedure well, and had decreased pain and improved range of motion. He was discharged with a sling, swathe, and orthopedic follow-up. Point-of-care ultrasound of the shoulder may be used to demonstrate posterior shoulder dislocation. This may have particular utility in the setting of non-diagnostic radiographs. Copyright © 2013. Published by Elsevier Inc.
Spring Ankle with Regenerative Kinetics to Build a New Generation of Transtibial Prostheses
2008-07-31
form factor that is portable to the wearer. The objective is to build a transtibial prosthesis that will support a Military amputee’s return to...active duty. 15. SUBJECT TERMS Transtibial Prosthesis , regenerative, spring, wearable robot 16. SECURITY CLASSIFICATION OF: 17. LIMITATION...Regenerative Kinetics” to build a new generation of transtibial prostheses Keywords: Transtibial Prosthesis , regenerative, spring, wearable robot
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voet, Peter W. J.; Dirkx, Maarten L. P.; Breedveld, Sebastiaan
2013-07-15
Purpose: To compare IMRT planning strategies for prostate cancer patients with metal hip prostheses.Methods: All plans were generated fully automatically (i.e., no human trial-and-error interactions) using iCycle, the authors' in-house developed algorithm for multicriterial selection of beam angles and optimization of fluence profiles, allowing objective comparison of planning strategies. For 18 prostate cancer patients (eight with bilateral hip prostheses, ten with a right-sided unilateral prosthesis), two planning strategies were evaluated: (i) full exclusion of beams containing beamlets that would deliver dose to the target after passing a prosthesis (IMRT{sub remove}) and (ii) exclusion of those beamlets only (IMRT{sub cut}). Plansmore » with optimized coplanar and noncoplanar beam arrangements were generated. Differences in PTV coverage and sparing of organs at risk (OARs) were quantified. The impact of beam number on plan quality was evaluated.Results: Especially for patients with bilateral hip prostheses, IMRT{sub cut} significantly improved rectum and bladder sparing compared to IMRT{sub remove}. For 9-beam coplanar plans, rectum V{sub 60Gy} reduced by 17.5%{+-} 15.0% (maximum 37.4%, p= 0.036) and rectum D{sub mean} by 9.4%{+-} 7.8% (maximum 19.8%, p= 0.036). Further improvements in OAR sparing were achievable by using noncoplanar beam setups, reducing rectum V{sub 60Gy} by another 4.6%{+-} 4.9% (p= 0.012) for noncoplanar 9-beam IMRT{sub cut} plans. Large reductions in rectum dose delivery were also observed when increasing the number of beam directions in the plans. For bilateral implants, the rectum V{sub 60Gy} was 37.3%{+-} 12.1% for coplanar 7-beam plans and reduced on average by 13.5% (maximum 30.1%, p= 0.012) for 15 directions.Conclusions: iCycle was able to automatically generate high quality plans for prostate cancer patients with prostheses. Excluding only beamlets that passed through the prostheses (IMRT{sub cut} strategy) significantly improved OAR sparing. Noncoplanar beam arrangements and, to a larger extent, increasing the number of treatment beams further improved plan quality.« less
Shoulder pain -- a common problem in world-class badminton players.
Fahlström, Martin; Yeap, Joo Seng; Alfredson, Håkan; Söderman, Kerstin
2006-06-01
Badminton is a sport that requires a lot of over-shoulder motion, with the shoulder in abduction/external rotation. This questionnaire study on 188 international top-level badminton players during the World Mixed Team Championships showed that previous or present shoulder pain on the dominant side was reported by 52% of the players. Previous shoulder pain was reported by 37% of the players and on-going shoulder pain by 20% of the players. There were no significant differences in the prevalence of shoulder pain between men and women. The majority of the shoulder pain had started gradually. The pain was usually associated with shoulder activity, and stiffness was a common, associated symptom. Furthermore, the shoulder pain was associated with consequences such as sleeping disturbances, changes in training and competition habits, and it also affected activities of daily living. The majority of the players had sought medical advice and had been given different kinds of treatment. The study showed that shoulder pain is a common and significant problem in world-class badminton players, and the consequences are most likely of importance for their training and playing capacity.
Fairbairn, Jessica R; Huxel Bliven, Kellie C
2018-02-06
Clinical Scenario: Until recently, injury epidemiology data on elite Paralympic athletes was limited. Current data suggests high rates of shoulder injury in wheelchair athletes. Differences in shoulder injury rates between sports have not been reported in this population. Is the incidence of shoulder injury in elite wheelchair athletes different between sports? Summary of Key Findings: Shoulder injury rates are high in elite wheelchair athletes, particularly in sports such as field events and fencing that require a stable base (eg, trunk, core control) from which to perform. Wheelchair racing requires repetitive motions that contribute to shoulder injuries, but rates are lower than field sports and fencing. Wheelchair curling and sledge hockey have low shoulder injury risk. Clinical Bottom Line: Shoulder injury rates vary based on sport in elite wheelchair athletes. In addition to incorporating shoulder complex specific rehabilitation for overuse shoulder injuries, clinicians should focus on core and trunk stabilization in elite wheelchair athletes competing in sports such as field events and fencing. Strength of Recommendation: Grade C evidence exists that reports shoulder injury rates among elite wheelchair athletes differ base upon sport participation.
Kim, Min-Hee; Yoo, Won-Gyu
2015-06-05
According to a recent research, manual working with high levels of static contraction, repetitive loads, or extreme working postures involving the neck and shoulder muscles causes an increased risk of neck and shoulder musculoskeletal disorders. We investigated the effects of the forwardly worktable position on head and shoulder angles and shoulder muscle activity in manual material handling tasks. The forward head and shoulder angles and the activity of upper trapezius, levator scapulae, and middle deltoid muscle activities of 15 workers were measured during performing of manual material handling in two tasks that required different forward head and shoulder angles. The second manual material task required a significantly increased forward head and shoulder angle. The upper trapezius and levator scapulae muscle activity in second manual material task was increased significantly compared with first manual material task. The middle deltoid muscle activity in second manual material task was not significantly different compared with first manual material task. Based on this result, the forward head and shoulder angles while performing manual work need to be considered in selection of the forward distance of a worktable form the body. The high level contractions of the neck and shoulder muscles correlated with neck and shoulder pain. Therefore, the forward distance of a worktable can be an important factor in preventing neck and shoulder pain in manual material handling workers.
Shoulder Injuries in US Astronauts Related to EVA Suit Design
NASA Technical Reports Server (NTRS)
Scheuring, Rick; McCulloch, Pat; Van Baalen, Mary; Watson, Richard; Bowen, Steve; Blatt, Terri
2012-01-01
There are multiple factors associated with the mechanism of injury that leads to shoulder injury requiring surgical repair. Despite the injury prevention measures taken from the 2003 Shoulder Tiger Team recommendations, shoulder injuries and subsequent shoulder surgeries remain relatively unchanged.
Shoulder internal rotation elbow flexion test for diagnosing cubital tunnel syndrome.
Ochi, Kensuke; Horiuchi, Yukio; Tanabe, Aya; Waseda, Makoto; Kaneko, Yasuhito; Koyanagi, Takahiro
2012-06-01
Shoulder internal rotation enhances symptom provocation attributed to cubital tunnel syndrome. We present a modified elbow flexion test--the shoulder internal rotation elbow flexion test--for diagnosing cubital tunnel syndrome. Fifty-five ulnar nerves in cubital tunnel syndrome patients and 123 ulnar nerves in controls were examined with 5 seconds each of elbow flexion, shoulder internal rotation, and shoulder internal rotation elbow flexion tests before and after treatment (surgery in 18; conservative in others). For the shoulder internal rotation elbow flexion test position, 90° abduction, maximum internal rotation, and 10° flexion of the shoulder were combined with the elbow flexion test position. The test was considered positive if any symptom for cubital tunnel syndrome developed <5 seconds. Influence of the shoulder internal rotation elbow flexion test was evaluated by nerve conduction studies in 10 cubital tunnel syndrome nerves and 7 control nerves. The sensitivities/specificities of the 5-second elbow flexion, shoulder internal rotation, and shoulder internal rotation elbow flexion tests were 25%/100%, 58%/100%, and 87%/98%, respectively. Sensitivity differences between the shoulder internal rotation elbow flexion test and the other two tests were significant. Shoulder internal rotation elbow flexion test results and cubital tunnel syndrome symptoms were significantly correlated. Influence of the shoulder internal rotation elbow flexion test on the ulnar nerve was seen in 8 of 10 cubital tunnel syndrome nerves but not in controls. The 5-second shoulder internal rotation elbow flexion test is specific, easy and quick provocative test for diagnosing cubital tunnel syndrome. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Specific Shoulder Pathoanatomy in Semiprofessional Water Polo Players
Klein, Maria; Tarantino, Ignazio; Warschkow, René; Berger, Claus Joachim; Zdravkovic, Vilijam; Jost, Bernhard; Badulescu, Michael
2014-01-01
Background: Shoulders of throwing and swimming athletes are highly stressed joints that often show structural abnormalities on magnetic resonance imaging (MRI). However, while water polo players exhibit a combination of throwing and swimming movements, a specific pattern of pathological findings has not been described. Purpose: To assess specific MRI abnormalities in shoulders of elite water polo players and to compare these findings with a healthy control group. Study Design: Cross-sectional study; Level of evidence, 3. Methods: After performing a power analysis, volunteers were recruited for this study. Both shoulders of 28 semiprofessional water polo players and 15 healthy volunteers were assessed clinically (based on the Constant score) and had bilateral shoulder MRIs. The shoulders were clustered into 3 groups: 28 throwing and 28 nonthrowing shoulders of water polo athletes and 30 shoulders of healthy control subjects. Results: Twenty-eight male water polo players with an average age of 24 years and 15 healthy subjects (30 shoulders) with an average age of 31 years were examined. Compared with controls, significantly more MRI abnormalities in the water polo players' throwing shoulders could be found in the subscapularis, infraspinatus, and posterior labrum (P = .001, P = .024, and P = .041, respectively). Other structures showed no statistical differences between the 3 groups, including the supraspinatus tendon, which had abnormalities in 36% of throwing versus 32% of nonthrowing shoulders and 33% of control shoulders. All throwing shoulders showed abnormal findings in the MRI, but only 8 (29%) were symptomatic. Conclusion: The shoulders of semiprofessional water polo players demonstrated abnormalities in subscapularis and infraspinatus tendons that were not typical abnormalities for swimmers or throwing athletes. Clinical Relevance: The throwing shoulders of water polo players have specific MRI changes. Clinical symptoms do not correlate with the MRI findings. PMID:26535326
Using the Microsoft Kinect™ to assess 3-D shoulder kinematics during computer use.
Xu, Xu; Robertson, Michelle; Chen, Karen B; Lin, Jia-Hua; McGorry, Raymond W
2017-11-01
Shoulder joint kinematics has been used as a representative indicator to investigate musculoskeletal symptoms among computer users for office ergonomics studies. The traditional measurement of shoulder kinematics normally requires a laboratory-based motion tracking system which limits the field studies. In the current study, a portable, low cost, and marker-less Microsoft Kinect™ sensor was examined for its feasibility on shoulder kinematics measurement during computer tasks. Eleven healthy participants performed a standardized computer task, and their shoulder kinematics data were measured by a Kinect sensor and a motion tracking system concurrently. The results indicated that placing the Kinect sensor in front of the participants would yielded a more accurate shoulder kinematics measurements then placing the Kinect sensor 15° or 30° to one side. The results also showed that the Kinect sensor had a better estimate on shoulder flexion/extension, compared with shoulder adduction/abduction and shoulder axial rotation. The RMSE of front-placed Kinect sensor on shoulder flexion/extension was less than 10° for both the right and the left shoulder. The measurement error of the front-placed Kinect sensor on the shoulder adduction/abduction was approximately 10° to 15°, and the magnitude of error is proportional to the magnitude of that joint angle. After the calibration, the RMSE on shoulder adduction/abduction were less than 10° based on an independent dataset of 5 additional participants. For shoulder axial rotation, the RMSE of front-placed Kinect sensor ranged between approximately 15° to 30°. The results of the study suggest that the Kinect sensor can provide some insight on shoulder kinematics for improving office ergonomics. Copyright © 2017 Elsevier Ltd. All rights reserved.
Jauch, S Y; Huber, G; Hoenig, E; Baxmann, M; Grupp, T M; Morlock, M M
2011-06-03
Hip prostheses with a modular neck exhibit, compared to monobloc prostheses, an additional interface which bears the risk of fretting as well as corrosion. Failures at the neck adapter of modular prostheses have been observed for a number of different designs. It has been speculated that micromotions at the stem-neck interface were responsible for these implant failures. The purpose of this study was to investigate the influence of material combinations and assembly conditions on the magnitude of micromotions at the stem-neck interface during cyclic loading. Modular (n = 24) and monobloc (n = 3) hip prostheses of a similar design (Metha, Aesculap AG, Tuttlingen, Germany) were subjected to mechanical testing according to ISO 7206-4 (F(min) = 230N, F(max) = 2300N, f = 1Hz, n = 10,000 cycles). The neck adapters (Ti-6Al-4V or Co-Cr29-Mo alloy) were assembled with a clean or contaminated interface. The micromotion between stem and neck adapter was calculated at five reference points based on the measurements of the three eddy current sensors. The largest micromotions were observed at the lateral edge of the stem-neck taper connection, which is in accordance with the crack location of clinically failed prostheses. Titanium neck adapters showed significantly larger micromotions than cobalt-chromium neck adapters (p = 0.005). Contaminated interfaces also exhibited significantly larger micromotions (p < 0.001). Since excessive micromotions at the stem-neck interface might be involved in the process of implant failure, special care should be taken to clean the interface prior to assembly and titanium neck adapters with titanium stems should generally be used with caution. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kobayashi, Toshiki; Arabian, Adam K; Orendurff, Michael S; Rosenbaum-Chou, Teri G; Boone, David A
2014-01-01
Energy storage and return feet are designed for active amputees. However, little is known about the socket reaction moments in transtibial prostheses with energy storage and return feet. The aim of this study was to investigate the effect of alignment changes on the socket reaction moments during gait while using the energy storage and return feet. A Smart Pyramid™ was used to measure the socket reaction moments in 10 subjects with transtibial prostheses while walking under 25 alignment conditions, including a nominal alignment (as defined by conventional clinical methods), as well as angle malalignments of 2°, 4° and 6° (flexion, extension, abduction, and adduction) and translation malalignments of 5mm, 10mm and 15mm (anterior, posterior, lateral, and medial) referenced from the nominal alignment. The socket reaction moments of the nominal alignment were compared with each malalignment. Both coronal and sagittal alignment changes demonstrated systematic effects on the socket reaction moments. In the sagittal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the minimum moment, the moment at 45% of stance and the maximum moment for some comparisons. In the coronal plane, angle and translation alignment changes demonstrated significant differences (P<0.05) in the moment at 30% and 75% of stance for all comparisons. The alignment may have systematic effects on the socket reaction moments in transtibial prostheses with energy storage and return feet. The socket reaction moments could potentially be a useful biomechanical parameter to evaluate the alignment of the transtibial prostheses. Copyright © 2013 Elsevier Ltd. All rights reserved.
Kron, B
1992-10-01
The interest of surgical prostheses in the palliative treatment of biliary tract cancer is well established, on the basis of their good tolerance, the more than 15 year follow up experience and the number of patients operated upon. After exeresis, they allow re-establishment of continuity, either by use of a prosthesis in Y when the right and let ducts can be dissected, or by using two prostheses, a multiperforated long prosthesis reimplanted in the duodenum and a short prosthesis reimplanted in the common bile duct without attaining the sphincter of Oddi. Of the 1000 cases treated, 500 were the object of a statistical analysis, 46 being operated upon by the author, in 60% of cases for biliary tract cancer, either primary or as an extension from the gallbladder. One-third of the patients had advanced lesions and a short survival of less than 3 months. Two-thirds a median survival of 9 months. In 10%, a radical exeresis was performed with survival of more than one year without recurrence of jaundice. Failure of treatment with persistence of jaundice was due to advanced disease for which surgery is unsatisfactory. Essential complications were premature bile leaks (5%) without serious consequences if sufficient drainage was maintained, since it stopped spontaneously, and angiocholitis (6%), the result of territory exclusion or reflux. Recurrence of jaundice was related to extension of the neoplasm to the secondary bile ducts, and to hepatic metastases. Obstruction of the prosthesis before two months was rare (6%) and was preceded by angiocholitis. In the absence of recurrence of the cancer the prosthesis can be replaced surgically without difficulty.
Samaniego Alonso, R; Gaviria Parada, E; Pons Cabrafiga, M; Espallargues Carreras, M; Martinez Cruz, O
2018-02-28
In our environment, it is increasingly necessary to perform an activity based on scientific evidence and the field of prosthetic surgery should be governed by the same principles. The national arthroplasty registries allow us to obtain a large amount of data in order to evaluate this technique. The aim of our study is to analyse the scientific evidence that supports the primary total knee arthroplasties implanted in Catalonian public hospitals, based on the Arthoplasty Registry of Catalonia (RACat) MATERIAL AND METHODS: A review of the literature was carried out on knee prostheses (cruciate retaining, posterior stabilized, constricted and rotational) recorded in RACat between the period 2005-2013 in the following databases: Orthopedic Data Evaluation Panel, PubMed, TripDatabase and Google Scholar. The prostheses implanted in fewer than 10 units (1,358 prostheses corresponding to 62 models) were excluded. 41,947 prostheses (96.86%) were analysed out of 43,305 implanted, corresponding to 74 different models. In 13 models (n = 4,715) (11.24%) no clinical evidence to support their use was found. In the remaining 36 models (n = 13,609) (32.45%), level iv studies were the most predominant evidence. There was a significant number of implanted prostheses (11.24%) for which no clinical evidence was found. The number of models should be noted, 36 out of 110, with fewer than 10 units implanted. The use of arthroplasty registries has proved an extremely useful tool that allows us to analyse and draw conclusions in order to improve the efficiency of this surgical technique. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Implants for elderly patients.
Schimmel, Martin; Müller, Frauke; Suter, Valérie; Buser, Daniel
2017-02-01
In the developed world, the large birth cohorts of the so-called baby boomer generation have arrived in medical and dental practices. Often, elderly patients are 'young-old' baby boomers in whom partial edentulism is the predominant indication for implant therapy. However, the generation 85+ years of age represents a new challenge for the dental profession, as their lives are frequently dominated by dependency, multimorbidity and frailty. In geriatric implant dentistry, treatment planning is highly individualized, as interindividual differences become more pronounced with age. Nevertheless, there are four typical indications for implant therapy: (i) avoidance of removable partial prostheses; (ii) preservation of existing removable partial prostheses; (iii) stabilization of Kennedy Class I removable partial prostheses; and (iv) stabilization of complete prostheses. From a surgical point of view, two very important aspects must be considered when planning implant surgery in elderly patients: first, the consistent strive to minimize morbidity; and, second, the fact that coexisting medical risk factors are significantly more common in elderly patients. Modern three-dimensional cone beam computed tomography imaging is often indicated in order to plan minimally invasive implant surgery. Computer-assisted implant surgery might allow flapless implant surgery, which offers a low level of postoperative morbidity and a minimal risk of postsurgical bleeding. Short and reduced-diameter implants are now utilized much more often than a decade ago. Two-stage surgical procedures should be avoided in elderly patients. Implant restorations for elderly patients should be designed so that they can be modified to become low-maintenance prostheses, or even be removed, as a strategy to facilitate oral hygiene and comfort in the final stage of life. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dewanjee, M.K.; Fuster, V.; Rao, S.A.
1983-05-01
A noninvasive technique has been developed in the dog model for imaging, with a gamma camera, the platelet deposition on Bjoerk-Shiley mitral valve prostheses early postoperatively. At 25 hours after implantation of the prosthesis and 24 hours after intravenous administration of 400 to 500 microCi of platelets labeled with indium-111, the platelet deposition in the sewing ring and perivalvular cardiac tissue can be clearly delineated in a scintiphotograph. An in vitro technique was also developed for quantitation of visceral microemboli in brain, lungs, kidneys, and other tissues. Biodistribution of the labeled platelets was quantitated, and the tissue/blood radioactivity ratio wasmore » determined in 22 dogs in four groups: unoperated normal dogs, sham-operated dogs, prosthesis-implanted dogs, and prosthesis-implanted dogs treated with dipyridamole before and aspirin and dipyridamole immediately after operation. Fifteen to 20% of total platelets were consumed as a consequence of the surgical procedure. On quantitation, we found that platelet deposition on the components of the prostheses was significantly reduced in prosthesis-implanted animals treated with dipyridamole and aspirin when compared with prosthesis-implanted, untreated dogs. All prosthesis-implanted animals considered together had a twofold to fourfold increase in tissue/blood radioactivity ratio in comparison with unoperated and sham-operated animals, an indication that the viscera work as filters and trap platelet microemboli that are presumably produced in the region of the mitral valve prostheses. In the dog model, indium-111-labeled platelets thus provide a sensitive marker for noninvasive imaging of platelet deposition on mechanical mitral valve prostheses, in vitro evaluation of platelet microembolism in viscera, in vitro quantitation of surgical consumption of platelets, and evaluation of platelet-inhibitor drugs.« less
Allen, Finbarr; McMillan, Anne
2002-06-01
The loss of natural teeth compromises chewing efficiency, and edentulous patients often have a diet that is deficient in fibre and vitamins. Prostheses that are retained on implants offer the possibility of overcoming some of the limitations of conventional dentures in terms of chewing efficiency. The aim of this study was to test the hypothesis that improvement in satisfaction with oral prostheses would result in improved food selection in edentulous patients. This prospective study involved three groups, namely (i) subjects who requested and received implants to stabilise a complete fixed or removable prosthesis (IG, n = 26), (ii) edentulous subjects who requested implant prostheses, but received conventional dentures (CDG1, n = 22), and (iii) edentulous subjects who requested and received conventional dentures (CDG2, n = 35). Data were collected using validated questionnaires pre- and postoperatively. Prior to treatment, all subjects were asked whether they ate a variety of hard and soft foods, to indicate the degree of difficulty they experienced when chewing these foods, and to rate their satisfaction with various aspects of their maxillary and mandibular complete dentures. Following the completion of treatment, subjects completed the questionnaires again. Pre- and postoperative data were compared. Subjects who received implant prostheses reported significant improvement in chewing hard and soft foods. CDG2 subjects also reported improvement, but CDG1 subjects reported no change or even deterioration following treatment. Despite reported improvement in satisfaction with comfort and ability to chew food, 30-50% of IG and CDG2 subjects still avoided eating foods such as carrot and apple. This suggests that, in the absence of tailored dietary advice, apparently successful prosthetic rehabilitation does not necessarily result in a satisfactory diet.
Functional changes through the usage of 3D-printed transitional prostheses in children.
Zuniga, Jorge M; Peck, Jean L; Srivastava, Rakesh; Pierce, James E; Dudley, Drew R; Than, Nicholas A; Stergiou, Nicholas
2017-11-08
There is limited knowledge on the use of 3 D-printed transitional prostheses, as they relate to changes in function and strength. Therefore, the purpose of this study was to identify functional and strength changes after usage of 3 D-printed transitional prostheses for multiple weeks for children with upper-limb differences. Gross manual dexterity was assessed using the Box and Block Test and wrist strength was measured using a dynamometer. This testing was conducted before and after a period of 24 ± 2.61 weeks of using a 3 D-printed transitional prosthesis. The 11 children (five girls and six boys; 3-15 years of age) who participated in the study, were fitted with a 3 D-printed transitional partial hand (n = 9) or an arm (n = 2) prosthesis. Separate two-way repeated measures ANOVAs were performed to analyze function and strength data. There was a significant hand by time interaction for function, but not for strength. Conclusion and relevance to the study of disability and rehabilitation: The increase in manual gross dexterity suggests that the Cyborg Beast 2 3 D-printed prosthesis can be used as a transitional device to improve function in children with traumatic or congenital upper-limb differences. Implications for Rehabilitation Children's prosthetic needs are complex due to their small size, rapid growth, and psychosocial development. Advancements in computer-aided design and additive manufacturing offer the possibility of designing and printing transitional prostheses at a very low cost, but there is limited knowledge on the function of this type of devices. The use of 3D printed transitional prostheses may improve manual gross dexterity in children after several weeks of using it.
Effect of beverages and mouthwashes on the hardness of polymers used in intraoral prostheses.
Goiato, Marcelo Coelho; Dos Santos, Daniela Micheline; Andreotti, Agda Marobo; Nobrega, Adhara Smith; Moreno, Amalia; Haddad, Marcela Filié; Pesqueira, Aldiéris Alves
2014-10-01
The mechanical properties of acrylic resins used in intraoral prostheses may be altered by frequent exposure to liquids such as beverages and mouthwashes. This study aimed to evaluate the effect of thermocycling and liquid immersion on the hardness of four brands of acrylic resins commonly used in removable prostheses (Onda Cryl, QC-20, Clássico, Lucitone). For each brand of resin, seven specimens were immersed in each of six solutions (coffee, cola, red wine, Plax-Colgate, Listerine [LI], Oral B), and seven more were placed in artificial saliva (control). The hardness was tested using a microhardness tester before and after 5000 thermocycles and after 1, 3, 24, 48, and 96 hours of immersion. The results were analyzed using three-way repeated-measures ANOVA and Tukey's test (p < 0.05). The hardness of the resins decreased following thermocycling and immersion in the solutions. Specimens immersed in cola and wine exhibited significant decreases in hardness after immersion for 96 hours, although the greatest significant decrease in hardness occurred in specimens immersed in LI. However, according to American Dental Association specification 12, the Knoop hardness of acrylic resins for intraoral prostheses should not be below 15. Thus, the median values of superficial hardness observed in most of the acrylic resins in this study are considered clinically acceptable. The microhardness of polymers used for intraoral prostheses decreases following thermocycling. Among specimens immersed in beverages, those immersed in cola or wine experienced the greatest decrease in microhardness. Immersion of acrylic resins in LI significantly decreased the microhardness in relation to the initial value. Among the resins assessed, QC-20 exhibited the lowest initial hardness. © 2014 by the American College of Prosthodontists.
Mituuti, Cláudia T; Bianco, Vinicius C; Bentim, Cláudia G; de Andrade, Eduardo C; Rubo, José H; Berretin-Felix, Giédre
2015-01-01
According to the literature, the occurrence of dysphagia is high in cases of stroke, and its severity can be enhanced by loss of teeth and the use of poorly fitting prostheses. To verify that the status of oral health influences the level of oral intake and the degree of swallowing dysfunction in elderly patients with stroke in chronic phase. Thirty elderly individuals affected by stroke in chronic phase participated. All subjects underwent assessment of their oral condition, with classification from the Functional Oral Intake Scale (FOIS) and nasoendoscopic swallowing assessment to classify the degree of dysphagia. The statistical analysis examined a heterogeneous group (HG, n=30) and two groups designated by the affected body part, right (RHG, n=8) and left (LHG, n=11), excluding totally dentate or edentulous individuals without rehabilitation with more than one episode of stroke. There was a negative correlation between the need for replacement prostheses and the FOIS scale for the HG (P=0.02) and RHG (P=0.01). Differences in FOIS between types of prostheses of the upper dental arch in the LHG (P=0.01) and lower dental arch in the RHG (P=0.04). A negative correlation was found between the number of teeth present and the degree of dysfunction in swallowing liquid in the LHG (P=0.05). There were differences in the performance in swallowing solids between individuals without prosthesis and those with partial prosthesis in the inferior dental arch (P=0.04) for the HG. The need for replacement prostheses, type of prostheses, and the number of teeth of elderly patients poststroke in chronic phase showed an association with the level of oral intake and the degree of oropharyngeal dysphagia.
An integrated CAD/CAM/robotic milling method for custom cementless femoral prostheses.
Wen-ming, Xi; Ai-min, Wang; Qi, Wu; Chang-hua, Liu; Jian-fei, Zhu; Fang-fang, Xia
2015-09-01
Aseptic loosening is the primary cause of cementless femoral prosthesis failure and is related to the primary stability of the cementless femoral prosthesis in the femoral cavity. The primary stability affects both the osseointegration and the long-term stability of cementless femoral prostheses. A custom cementless femoral prosthesis can improve the fit and fill of the prosthesis in the femoral cavity and decrease the micromotion of the proximal prosthesis such that the primary stability of the custom prosthesis can be improved, and osseointegration of the proximal prosthesis is achieved. These results will help to achieve long-term stability in total hip arthroplasty (THA). In this paper, we introduce an integrated CAD/CAM/robotic method of milling custom cementless femoral prostheses. The 3D reconstruction model uses femoral CT images and 3D design software to design a CAD model of the custom prosthesis. After the transformation matrices between two units of the robotic system are calibrated, consistency between the CAM software and the robotic system can be achieved, and errors in the robotic milling can be limited. According to the CAD model of the custom prosthesis, the positions of the robotic tool points are produced by the CAM software of the CNC machine. The normal vector of the three adjacent robotic tool point positions determines the pose of the robotic tool point. In conclusion, the fit rate of custom pig femur stems in the femoral cavities was 90.84%. After custom femoral prostheses were inserted into the femoral cavities, the maximum gaps between the prostheses and the cavities measured less than 1 mm at the diaphysis and 1.3 mm at the metaphysis. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
Ortorp, A; Linden, B; Jemt, T
1999-01-01
The purpose of this study was to report the 5-year clinical performance of implant-supported prostheses with laser-welded titanium frameworks and to compare their performance with that of prostheses provided with conventional cast frameworks. On a routine basis, a consecutive group of 824 edentulous patients were provided with fixed prostheses supported by implants in the edentulous mandible. In addition to conventional gold-alloy castings, patients were at random provided with 2 kinds of laser-welded titanium frameworks. In all, 155 patients were included in the 2 titanium framework groups. A control group of 53 randomly selected patients with conventional gold-alloy castings was used for comparison. Clinical and radiographic 5-year data was collected for the 3 groups. All followed patients still had fixed prostheses in the mandible after 5 years. The overall cumulative success rates were 95.9% and 99.7% for titanium-framework prostheses and implants, respectively. The corresponding success rates for the control group were 100% and 99.6%, respectively. Bone loss was 0.5 mm on average during the 5-year follow-up period. The most common complications for titanium frameworks were resin or tooth fractures, gingival inflammation, and fractures of the metal frames (10%). One of the cast frameworks fractured and was resoldered. Loose and fractured implant screw components were few (< 1%). Even though the cast frameworks had a higher success rate, the overall titanium framework treatment result was well in accordance with the result of the control group. The test groups performed better after clinicians had gained some experience with the technique, and laser-welded titanium frameworks seem to be a viable alternative to conventional castings in the edentulous mandible.