Objectivity, Reliability, and Validity of the Bent-Knee Push-Up for College-Age Women
ERIC Educational Resources Information Center
Wood, Heather M.; Baumgartner, Ted A.
2004-01-01
The revised push-up test has been found to have good validity but it produces many zero scores for women. Maybe there should be an alternative to the revised push-up test for college-age women. The purpose of this study was to determine the objectivity, reliability, and validity for the bent-knee push-up test (executed on hands and knees) for…
History of United States Army physical fitness and physical readiness training.
Knapik, Joseph J; East, Whitfield B
2014-01-01
This article traces the history of US Army physical fitness assessments from the first test developed for Cadets at the US Military Academy in 1858 through efforts to revise the current Army Physical Fitness Test (APFT). The first "Individual Efficiency Test" (1920) for all Soldiers consisted of a 100-yard run, running broad jump, wall climb, hand grenade throw, and obstacle course. The first scientific efforts involved testing of 400 Soldiers and a factor analysis of 25 individual test items. In 1944, this resulted in a 7-item test (pull-up, burpee, squat jump, push-up, man-carry, sit-up and 300-yard run) with a 100-point scoring system. In 1943, women were encouraged to take a "self-assessment" consisting of push-ups, bent knee sit-ups, wing lifts, squat thrusts, running, and a stork stand. In 1946, age-adjusted standards were introduced and in 1965 semiannual fitness assessments were mandated. The number of tests proliferated in the 1969-1973 period with 7 separate assessments. The current APFT consisting of push-ups, sit-ups, and a 2-mile run was introduced in 1980 and alternative tests for those with physical limitations in 1982. Current efforts to revise the assessment involve systematic literature reviews and validating the relationship between test items and common Soldiering tasks.
Physical Test Prototypes Based on Microcontroller
NASA Astrophysics Data System (ADS)
Paramitha, S. T.
2017-03-01
The purpose of this study was to produce a prototype of a physical test-based microcontroller. The research method uses the research and development of the Borg and gall. The procedure starts from the study; research and information collecting, planning, develop preliminary form of product, preliminary field testing, main product revision, playing field testing, operational product revision, field operational testing, final product revision, dissemination and implementation. Validation of the product, obtained through expert evaluation; test products of small scale and large scale; effectiveness test; evaluation of respondents. The results showed that the eligibility assessment of prototype products based physical tests microcontroller. Based on the ratings of seven experts showed that 87% included in the category of “very good” and 13% included in the category of “good”. While the effectiveness of the test results showed that 1). The results of the experimental group to test sit-ups increase by 40% and the control group by 15%. 2). The results of the experimental group to test push-ups increased by 30% and the control group by 10%. 3). The results of the experimental group to test the Back-ups increased by 25% and the control group by 10%. With a significant value of 0.002 less than 0.05, product means a physical test prototype microcontroller based, proven effective in improving the results of physical tests. Conclusions and recommendations; Product physical microcontroller-based assays, can be used to measure the physical tests of pushups, sit ups, and back-ups.
Inter-Rater Reliability and Intra-Rater Reliability of Assessing the 2-Minute Push-Up Test.
Fielitz, Lynn; Coelho, Jeffrey; Horne, Thomas; Brechue, William
2016-02-01
The purpose of this study was to assess inter-rater reliability and intra-rater reliability of the 2-minute, 90° push-up test as utilized in the Army Physical Fitness Test. Analysis of rater assessment reliability included both total score agreement and agreement across individual push-up repetitions. This study utilized 8 Raters who assessed 15 different videotaped push-up performances over 4 iterations separated by a minimum of 1 week. The 15 push-up participants were videotaped during the semiannual Army Physical Fitness Test. Each Rater randomly viewed the 15 push-up and verbally responded with a "yes" or "no" to each push-up repetition. The data generated were analyzed using the Pearson product-moment correlation as well as the kappa, modified kappa and the intra-class correlation coefficient (3,1). An attribute agreement analysis was conducted to determine the percent of inter-rater and intra-rater agreement across individual push-ups.The results indicated that Raters varied a great deal in assessing push-ups. Over the 4 trials of 15 participants, the overall scores of the Raters varied between 3.0 and 35.7 push-ups. Post hoc comparisons found that there was significant increase in the grand mean of push-ups from trials 1-3 to trial 4 (p < 0.05). Also, there was a significant difference among raters over the 4 trials (p < 0.05). Pearson correlation coefficients for inter-rater and intra-rater reliability identified inter-rater reliability coefficients were between 0.10 and 0.97. Intra-rater coefficients were between 0.48 and 0.99. Intra-rater agreement for individual push-up repetitions ranged from 41.8% to 84.8%. The results indicated that the raters failed to assess the same push-up repetition with the same score (below 70% agreement) as well as failed to agree when viewed between raters (29%). Interestingly, as previously mentioned, scores on trial 4 increased significantly which might have been caused by rater drift or that the Raters did not maintain the push-up standard over the trials. It does appear that the final push-up scores received by each participant was a close approximation of actual performance (within 65%) but when assessing physical performance for retention in the Army, a more reliable test might be considered. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
States Slow Standards Work amid "Common Core" Push
ERIC Educational Resources Information Center
Zehr, Mary Ann
2009-01-01
As they wait to see how the latest push for common national standards plays out, some states are putting off or slowing the revision of their own academic standards to avoid wasted effort and spending. At least four states--Arkansas, Florida, Louisiana, and Pennsylvania--have halted revision of their standards for mathematics or English/language…
Combat Fitness a Concept Vital to National Defense
2010-06-18
Physical fitness testing has traditionally been focused on a 1.5- to 3-mile run, push-ups, sit-ups, and, in some Services pull -ups, flexibility, and...Performance 6 Shoot Physical Requirements Employ hand grenades Run under load, jump, bound, high/low crawl, climb, push, pull , squat, lunge, roll...jump, bound, high/low crawl, climb, push, pull , squat, lunge, roll, stop, start, change direction and get up/down. Navigate from one point to
A Field Test for Upper Body Strength and Endurance.
ERIC Educational Resources Information Center
Nelson, Jack K.; And Others
1991-01-01
Researchers studied the reliability of the modified push-up test in measuring upper body strength and endurance in elementary through college students. It also examined the accuracy of partner scoring. The test proved much easier to administer than the regular floor push-up. It was valid and reliable for all students and suitable for partner…
Upper body push and pull strength ratio in recreationally active adults.
Negrete, Rodney J; Hanney, William J; Pabian, Patrick; Kolber, Morey J
2013-04-01
Agonist to antagonist strength data is commonly analyzed due to its association with injury and performance. The purpose of this study was to examine the agonist to antagonist ratio of upper body strength using two simple field tests (timed push up/timed modified pull up) in recreationally active adults and to establish the basis for reference standards. One hundred eighty (180) healthy recreationally active adults (111 females and 69 males, aged 18-45 years) performed two tests of upper body strength in random order: 1. Push-ups completed during 3 sets of 15 seconds with a 45 second rest period between each set and 2. Modified pull-ups completed during 3 sets of 15 seconds with a 45 second rest period between each set. The push-up to modified pull-up ratio for the males was 1.57:1, whereas females demonstrated a ratio of 2.72:1. The results suggest that for our group of healthy recreationally active subjects, the upper body "pushing" musculature is approximately 1.5-2.7 times stronger than the musculature involved for pulling. In this study, these recreationally active adults displayed greater strength during the timed push-ups than the modified pull-ups. The relationship of these imbalances to one's performance and or injury risk requires further investigation. The reference values, however, may serve the basis for future comparison and prospective investigations. The field tests in this study can be easily implemented by clinicians and an agonist/antagonist ratio can be determined and compared to our findings. 2b.
Muscle Activation during Push-Ups with Different Suspension Training Systems.
Calatayud, Joaquin; Borreani, Sebastien; Colado, Juan C; Martín, Fernando F; Rogers, Michael E; Behm, David G; Andersen, Lars L
2014-09-01
The purpose of this study was to analyze upper extremity and core muscle activation when performing push-ups with different suspension devices. Young fit male university students (n = 29) performed 3 push-ups each with 4 different suspension systems. Push-up speed was controlled using a metronome and testing order was randomized. Average amplitude of the electromyographic root mean square of Triceps Brachii, Upper Trapezius, Anterior Deltoid, Clavicular Pectoralis, Rectus Abdominis, Rectus Femoris, and Lumbar Erector Spinae was recorded. Electromyographic signals were normalized to the maximum voluntary isometric contraction (MVIC). Electromyographic data were analyzed with repeated-measures analysis of variance with a Bonferroni post hoc. Based upon global arithmetic mean of all muscles analyzed, the suspended push-up with a pulley system provided the greatest activity (37.76% of MVIC; p < 0.001). Individually, the suspended push-up with a pulley system also provided the greatest triceps brachii, upper trapezius, rectus femoris and erector lumbar spinae muscle activation. In contrast, more stable conditions seem more appropriate for pectoralis major and anterior deltoid muscles. Independent of the type of design, all suspension systems were especially effective training tools for reaching high levels of rectus abdominis activation. Key PointsCompared with standard push-ups on the floor, suspended push-ups increase core muscle activation.A one-anchor system with a pulley is the best option to increase TRICEP, TRAPS, LUMB and FEM muscle activity.More stable conditions such as the standard push-up or a parallel band system provide greater increases in DELT and PEC muscle activation.A suspended push-up is an effective method to achieve high muscle activity levels in the ABS.
Muscle Activation during Push-Ups with Different Suspension Training Systems
Calatayud, Joaquin; Borreani, Sebastien; Colado, Juan C.; Martín, Fernando F; Rogers, Michael E.; Behm, David G.; Andersen, Lars L.
2014-01-01
The purpose of this study was to analyze upper extremity and core muscle activation when performing push-ups with different suspension devices. Young fit male university students (n = 29) performed 3 push-ups each with 4 different suspension systems. Push-up speed was controlled using a metronome and testing order was randomized. Average amplitude of the electromyographic root mean square of Triceps Brachii, Upper Trapezius, Anterior Deltoid, Clavicular Pectoralis, Rectus Abdominis, Rectus Femoris, and Lumbar Erector Spinae was recorded. Electromyographic signals were normalized to the maximum voluntary isometric contraction (MVIC). Electromyographic data were analyzed with repeated-measures analysis of variance with a Bonferroni post hoc. Based upon global arithmetic mean of all muscles analyzed, the suspended push-up with a pulley system provided the greatest activity (37.76% of MVIC; p < 0.001). Individually, the suspended push-up with a pulley system also provided the greatest triceps brachii, upper trapezius, rectus femoris and erector lumbar spinae muscle activation. In contrast, more stable conditions seem more appropriate for pectoralis major and anterior deltoid muscles. Independent of the type of design, all suspension systems were especially effective training tools for reaching high levels of rectus abdominis activation. Key Points Compared with standard push-ups on the floor, suspended push-ups increase core muscle activation. A one-anchor system with a pulley is the best option to increase TRICEP, TRAPS, LUMB and FEM muscle activity. More stable conditions such as the standard push-up or a parallel band system provide greater increases in DELT and PEC muscle activation. A suspended push-up is an effective method to achieve high muscle activity levels in the ABS. PMID:25177174
Myoelectric activation and kinetics of different plyometric push-up exercises.
García-Massó, Xavier; Colado, Juan C; González, Luis M; Salvá, Pau; Alves, Joao; Tella, Víctor; Triplett, N Travis
2011-07-01
The kinetic and myoelectric differences between 3 types of plyometric push-ups were investigated. Twenty-seven healthy, physically active men served as subjects and completed both familiarization and testing sessions. During these sessions, subjects performed 2 series of 3 plyometric push-up variations in a counterbalanced order according to the following techniques: Countermovement push-ups (CPUs) were push-ups performed with the maximum speed of movement; jump push-ups (JPUs) were similar to clapping push-ups; and fall push-ups (FPUs) required kneeling subjects to drop and then attempt to return to their initial position. Vertical ground reaction forces were determined by using a force plate. Myoelectric activity was recorded by means of electromyography. Impact force and impact rate of force development were significantly (p < 0.05) higher for FPUs than for JPUs. The maximum rate of force development was higher for CPUs (p < 0.05) than for JPUs, and the maximum force was higher for the CPUs than for the FPUs (p < 0.05). There were differences among exercises for the mean muscle activation of the pectoralis major (PM; p < 0.001), triceps brachii (p < 0.001), external oblique (p < 0.005) and anterior deltoid (p < 0.001), and in the maximum muscle activation of the PM (p < 0.001). Plyometric push-ups with countermovement achieved a higher maximum force and rate of force and did not cause impact forces. Thus, this type of push-up exercise may be regarded as the best for improving explosive force. The FPU exercise achieved higher levels of muscular activation in the agonist and synergist muscle groups, and greater impact forces and impact force development rates.
Borreani, Sebastien; Calatayud, Joaquin; Colado, Juan C; Tella, Victor; Moya-Nájera, Diego; Martin, Fernando; Rogers, Michael E
2015-08-01
To analyze shoulder muscle activation when performing push-ups under different stability conditions and heights. Comparative study by repeated measures. Valencia University laboratory. 29 healthy males participated. Subjects performed 3 push-ups each with their hands at 2 different heights (10 vs. 65 cm) under stable conditions and using a suspension device. Push-up speed was controlled and the testing order was randomized. The average amplitudes of the electromyographic root mean square of the long head of the triceps brachii (TRICEP), upper trapezius (TRAPS), anterior deltoid (DELT) and clavicular pectoralis (PEC) were recorded. The electromyographic signals were normalized to the maximum voluntary isometric contraction (MVIC). Suspended push-ups at 10 cm resulted in greater activation in the TRICEP (17.14 ± 1.31 %MVIC vs. 37.03 ± 1.80 %MVIC) and TRAPS (5.83 ± 0.58 %MVIC vs. 14.69 ± 1.91 %MVIC) than those performed on the floor. For DELT and PEC similar or higher activation was found performing the push-ups on the floor, respectively. Height determines different muscle activation patterns. Stable push-ups elicit similar PEC and higher DELT muscle activation, being greater at 10 cm; whereas suspended push-ups elicit greater TRAPS and TRICEP muscle activation, being greater at 65 cm. Copyright © 2014 Elsevier Ltd. All rights reserved.
Load-carriage distance run and push-ups tests: no body mass bias and occupationally relevant.
Vanderburgh, Paul M; Mickley, Nicholas S; Anloague, Philip A
2011-09-01
Recent research has demonstrated body mass (M) bias in military physical fitness tests favoring lighter, not just leaner, service members. Mathematical modeling predicts that a distance run carrying a backpack of 30 lbs would eliminate M-bias. The purpose of this study was to empirically test this prediction for the U.S. Army push-ups and 2-mile run tests. Two tests were performed for both events for each of 56 university Reserve Officer Training Corps male cadets: with (loaded) and without backpack (unloaded). Results indicated significant M-bias in the unloaded and no M-bias in the loaded condition for both events. Allometrically scaled scores for both events were worse in the loaded vs. unloaded conditions, supporting a hypothesis not previously tested. The loaded push-ups and 2-mile run appear to remove M-bias and are probably more occupationally relevant as military personnel are often expected to carry external loads.
Prone positioning reduces severe pushing behavior: three case studies.
Fujino, Yuji; Amimoto, Kazu; Sugimoto, Satoshi; Fukata, Kazuhiro; Inoue, Masahide; Takahashi, Hidetoshi; Makita, Shigeru
2016-09-01
[Purpose] Pushing behavior is classically described as a disorder of body orientation in the coronal plane. Most interventions for pushing behavior have focused on correcting the deviation in vertical perception. However, pushing behavior seems to involve erroneous movements associated with excessive motor output by the non-paretic limbs and trunk. The present study aimed to inhibit muscular hyper-activity by placing the non-paretic limbs and trunk in the prone position. [Subjects and Methods] The subjects of the present study were 3 acute stroke patients with severe pushing behavior. The study consisted of the following 3 phases: baseline, intervention, and follow-up. In addition to conventional therapy, patients received relaxation therapy in the prone position for 10 minutes a day over 2 days. The severity of pushing behavior was assessed using the scale for contraversive pushing, and truncal balance was evaluated using the trunk control test. These assessments were performed before and after the baseline phase, and after the intervention and follow-up phases. [Results] At the baseline phase, both scores were poor. Both scores improved after the intervention and follow-up phases, and all the patients could sit independently. [Conclusion] Relaxation therapy in the prone position might ameliorate pushing behavior and impaired truncal balance.
Social Awareness and Leader Influence: A Proposed Model and Training Intervention
2007-07-01
lips pulled down • Lower lip pushed up • Corner of lips tightened and pressed • Soft volume • Slow pace • Monotone • Head tilted downward...an overall approach or strategy for the influence attempt (e.g., one strategy might be to rely on logical arguments to convince the target that it is...Behavior/ Influence Tactics Target’s Interpretation Target’s Reaction Influencer’s Revised Strategy Influence Goal Evaluation of the Situation
Delayed versus immediate pushing in second stage of labor.
Kelly, Mary; Johnson, Eileen; Lee, Vickie; Massey, Liz; Purser, Debbie; Ring, Karen; Sanderson, Stephanye; Styles, Juanita; Wood, Deb
2010-01-01
Comparison of two different methods for management of second stage of labor: immediate pushing at complete cervical dilation of 10 cm and delayed pushing 90 minutes after complete cervical dilation. This study was a randomized clinical trial in a labor and delivery unit of a not-for-profit community hospital. A sample of 44 nulliparous mothers with continuous epidural anesthesia were studied after random assignment to treatment groups. Subjects were managed with either immediate or delayed pushing during the second stage of labor at the time cervical dilation was complete. The primary outcome measure was the length of pushing during second stage of labor. Secondary outcomes included length of second stage of labor, maternal fatigue and perineal injuries, and fetal heart rate decelerations. Two-tailed, unpaired Student's t-tests and Chi-square analysis were used for data analysis. Level of significance was set at p < .01 following a Bonferroni correction for multiple t-tests. A total of 44 subjects received the study intervention (N = 28 immediate pushing; N = 16 delayed pushing). The delayed pushing group had significantly shorter amount of time spent in pushing compared with the immediate pushing group (38.9 +/- 6.9 vs. 78.7 +/- 7.9 minutes, respectively, p = .002). Maternal fatigue scores, perineal injuries, and fetal heart rate decelerations were similar for both groups. Delaying pushing for up to 90 minutes after complete cervical dilation resulted in a significant decrease in the time mothers spent pushing without a significant increase in total time in second stage of labor.In clinical practice, healthcare providers sometimes resist delaying the onset of pushing after second stage of labor has begun because of a belief it will increase labor time. This study's finding of a 51% reduction in pushing time when mothers delay pushing for up to 90 minutes, with no significant increase in overall time for second stage of labor, disputes that concern.
Prone positioning reduces severe pushing behavior: three case studies
Fujino, Yuji; Amimoto, Kazu; Sugimoto, Satoshi; Fukata, Kazuhiro; Inoue, Masahide; Takahashi, Hidetoshi; Makita, Shigeru
2016-01-01
[Purpose] Pushing behavior is classically described as a disorder of body orientation in the coronal plane. Most interventions for pushing behavior have focused on correcting the deviation in vertical perception. However, pushing behavior seems to involve erroneous movements associated with excessive motor output by the non-paretic limbs and trunk. The present study aimed to inhibit muscular hyper-activity by placing the non-paretic limbs and trunk in the prone position. [Subjects and Methods] The subjects of the present study were 3 acute stroke patients with severe pushing behavior. The study consisted of the following 3 phases: baseline, intervention, and follow-up. In addition to conventional therapy, patients received relaxation therapy in the prone position for 10 minutes a day over 2 days. The severity of pushing behavior was assessed using the scale for contraversive pushing, and truncal balance was evaluated using the trunk control test. These assessments were performed before and after the baseline phase, and after the intervention and follow-up phases. [Results] At the baseline phase, both scores were poor. Both scores improved after the intervention and follow-up phases, and all the patients could sit independently. [Conclusion] Relaxation therapy in the prone position might ameliorate pushing behavior and impaired truncal balance. PMID:27799722
Muscle activation during push-ups performed under stable and unstable conditions.
Borreani, Sebastien; Calatayud, Joaquin; Colado, Juan Carlos; Moya-Nájera, Diego; Triplett, N Travis; Martin, Fernando
2015-12-01
The purpose of this study was to analyze muscle activation when performing push-ups under different stability conditions. Physically fit young male university students ( N = 30) performed five push-ups under stable conditions (on the floor) and using four unstable devices (wobble board, stability disc, fitness dome, and the TRX Suspension Trainer). The push-up speed was controlled using a metronome, and the testing order was randomized. The average amplitudes of the electromyographic (EMG) root mean square of the anterior deltoid (DELT), serratus anterior (SERRA), lumbar multifidus (LUMB), and rectus femoris (FEM) were recorded. The electromyographic signals were normalized to the maximum voluntary isometric contraction (MVIC). No significant differences were found for the DELT [ F (4,112) = 1.978; p = 0.130] among the conditions. However, statistically significant differences were found among the different conditions for the SERRA [ F (4,60) = 17.649; p < 0.001], LUMB [ F (4,76) = 12.334; p < 0.001], and FEM [ F (4,104) = 24.676; p < 0.001] muscle activation. The suspended device was the only condition that elicited higher LUMB and FEM activation compared to the other conditions. Push-ups performed on the floor showed lower SERRA activation than those performed with all unstable devices. Not all unstable devices enhance muscle activation compared to traditional push-ups.
Effects of Angle Variations in Suspension Push-up Exercise.
Gulmez, Irfan
2017-04-01
Gulmez, I. Effects of angle variations in suspension push-up exercise. J Strength Cond Res 31(4): 1017-1023, 2017-This study aimed to determine and compare the amount of loads on the TRX Suspension Trainer (TRX) straps and ground reaction forces at 4 different angles during TRX push-ups. Twenty-eight male (mean age, 24.1 ± 2.9 years; height, 179.4 ± 8.0 m; weight, 78.8 ± 9.8 kg) physical education and sports university students participated in this study. The subjects were tested at TRX angles (0, 15, 30, 45°) during the TRX push-ups. Force data were recorded by a force platform and load cells integrated into the TRX straps. The results show that as the TRX angle was reduced, the load applied to the TRX straps increased and simultaneously the load measured by the force platform decreased. This was true for both the elbow joint changing from flexion to extension and vice versa. When the TRX angle was set at 0° and subjects' elbows were at extension during TRX push-up, 50.4% of the subjects' body weight, and when the elbows were at flexion, 75.3% of the body weight was registered by the sensors on the TRX straps. The results of this study can be used in the calculation of the training load and volume (resistance training programming) during TRX push-up exercises at varying angles.
Effect of External Loading on Force and Power Production During Plyometric Push-ups.
Hinshaw, Taylour J; Stephenson, Mitchell L; Sha, Zhanxin; Dai, Boyi
2018-04-01
Hinshaw, TJ, Stephenson, ML, Sha, Z, and Dai, B. Effect of external loading on force and power production during plyometric push-ups. J Strength Cond Res 32(4): 1099-1108, 2018-One common exercise to train upper-body strength and power is the push-up. Training at the loads that would produce the greatest power is an effective way to increase peak power. The purpose of the current study was to quantify the changes in peak force, peak power, and peak velocity among a modified plyometric push-up and plyometric push-ups with or without external loading in physically active young adults. Eighteen male and 17 female participants completed 4 push-ups: (a) modified plyometric push-up on the knees, (b) plyometric push-up without external loading, (c) plyometric push-up with an external load of 5% of body weight, and (d) plyometric push-up with an external load of 10% of body weight. Two force platforms were set up to collect vertical ground reaction forces at the hands and feet. The modified plyometric push-up demonstrated the lowest force, power, and velocity (5.4≥ Cohen's dz ≥1.2). Peak force and force at peak velocity increased (3.8≥ Cohen's dz ≥0.3) and peak velocity and velocity at peak power decreased (1.4≥ Cohen's dz ≥0.8) for the push-up without external loading compared with the 2 push-ups with external loading. No significant differences were observed for peak power among the push-ups with or without external loading (0.4≥ Cohen's dz ≥0.1). Although peak power is similar with or without external loading, push-ups without external loading may be more beneficial for a quick movement, and push-ups with external loading may be more beneficial for a greater force production.
Palmar pressure distribution during push-up exercise.
Chuckpaiwong, B; Harnroongroj, T
2009-07-01
Doing repetitive push-ups is among the most common exercise for the upper body and shoulder stabiliser muscle strength training. However, adverse effects such as neck pain, back pain, palmar pain and wrist pain have been reported. To date, to our knowledge, palmar pressure when performing push-ups has not been previously reported. We hypothesised that various hand positions during push-ups may provide different palmar pressures. Bilateral palmar pressures were recorded in ten individual volunteers. All the subjects were set up for doing push-ups in five positions of the hand. Peak palmar pressure was recorded by Emed pressure platform system (Novel GmBH, Munich, Germany). The palm was divided into the following five anatomic regions, viz. thenar, lunate, hypothenar, metacarpals and fingers. Statistical comparison between the five positions of the hand was analysed using the analysis of variance test. A distribution of the mean peak pressure of the lunate and hypothenar areas were relatively higher than the other areas in both standby and full-elbow flexion positions. At the palmar position 30 cm wider than the shoulder width, the palmar pressure revealed significantly higher peak pressure in the lunate area in the standby and fully-flexed elbow positions (p-value is less than 0.05). At the palmar position 10 cm narrower than the shoulder width, palmar pressure showed significantly higher peak pressure in the hypothenar area only in the fully-flexed elbow position. The information regarding palmar pressures while performing push-ups in different hand positions may be used as a guideline for exercise modification, especially in injured athletes.
Tucker, W Steven; Campbell, Brian M; Swartz, Erik E; Armstrong, Charles W
2008-01-01
The Cuff Link is a closed kinetic chain rehabilitation apparatus for the upper extremity. Limited research has established its effectiveness to elicit muscle activation of the scapular muscles. To determine if scapular muscle activation differs in response to 2 upper extremity closed kinetic chain exercises: Cuff Link and standard push-up. A single-group, repeated-measures design. Controlled laboratory. Twenty-eight healthy individuals (13 women: age = 19.69 +/- 1.55 years, height = 167.44 +/- 9.52 cm, mass = 61.00 +/- 8.79 kg; 15 men: age = 22.00 +/- 3.91 years, height = 181.44 +/- 6.60 cm, mass = 82.36 +/- 13.23 kg) with no history of shoulder or low back injury volunteered to participate in this study. Participants performed 10 trials of complete revolutions on the Cuff Link and 10 full-weight-bearing push-ups. We controlled trial velocity and randomized order. Trunk and shoulder positions were normalized to the participant's height. Using surface electromyography, we recorded muscle activity of the serratus anterior, middle trapezius, and lower trapezius. Rectified and smoothed electromyography data for the serratus anterior, middle trapezius, and lower trapezius were normalized as a percentage of the maximal voluntary isometric contractions (%MVIC). Mean muscle activity of the serratus anterior, middle trapezius, and lower trapezius. We used paired-samples t tests to analyze the mean data for each condition. The alpha level was adjusted to .016 to avoid a type I error. Middle trapezius %MVIC was greater during push-ups (27.01 +/- 20.40%) than during use of the Cuff Link (11.49 +/- 9.46%) (P = .001). Lower trapezius %MVIC was greater during push-ups (36.07 +/- 18.99%) than during use of the Cuff Link (16.29 +/- 8.64%) (P = .001). There was no difference in %MVIC for the serratus anterior between conditions. The push-up demonstrated greater middle trapezius and lower trapezius activation levels compared with the Cuff Link. However, the push-up had a high participant failure rate. Because serratus anterior activation levels were similar, the Cuff Link may be an appropriate alternative for individuals lacking the upper body strength to perform a push-up.
Push-out tests and evaluation of FRP perfobond rib shear connectors performance
NASA Astrophysics Data System (ADS)
Kolpasky, Ludvik; Ryjacek, Pavel
2017-09-01
The behavioural characteristics of FRP (fibre-reinforced polymer) perfobond rib shear connector was examined through push-out tests in order to verify the applicability for pedestrian bridge structure. The aim of this study is to determine interaction between high performance concrete slab and handmade FRP plate which represent web of the composite beam. Combination of these modern materials leads to structural system with both great load bearing capacity and also sufficient flexural stiffness of the composite element. Openings cut into the GFRP plate at a variable spacing allow GFRP reinforcement bars to be inserted to act as shear studs. Hand lay-up process can increase suitable properties of FRP for connection by perfobond rib shear connectors. In this study, three push-out tests on fiber-reinforced polymer were performed to investigate their shear behaviour. The results of the push-out tests on FRP perfobond rib shear connector indicates great promise for application in full scale structures.
Equivalence Reliability among the FITNESSGRAM[R] Upper-Body Tests of Muscular Strength and Endurance
ERIC Educational Resources Information Center
Sherman, Todd; Barfield, J. P.
2006-01-01
This study was designed to investigate the equivalence reliability between the suggested FITNESSGRAM[R] muscular strength and endurance test, the 90[degrees] push-up (PSU), and alternate FITNESSGRAM[R] tests of upper-body strength and endurance (i.e., modified pull-up [MPU], flexed-arm hang [FAH], and pull-up [PU]). Children (N = 383) in Grades 3…
Kinematic Analysis of Four Plyometric Push-Up Variations
MOORE, LAURA H.; TANKOVICH, MICHAEL J.; RIEMANN, BRYAN L.; DAVIES, GEORGE J.
2012-01-01
Plyometric research in the upper extremity is limited, with the effects of open-chain plyometric exercises being studied most. Kinematic and ground reaction force data concerning closed-chain upper extremity plyometrics has yet to be examined. Twenty-one recreationally active male subjects performed four variations of plyometric push-ups in a counterbalanced order. These included box drop push-ups from 3.8 cm, 7.6 cm, 11.4 cm heights, and clap push-ups. Kinematics of the trunk, dominant extremity and both hands were collected to examine peak flight, elbow flexion at ground contact, elbow displacement, and hand separation. Additionally peak vertical ground reaction force was measured under the dominant extremity. The 11.4 cm and clap push-ups had significantly higher peak flight than the other variations (P<.001). At ground contact, the elbow was in significantly greater flexion for the 3.8 cm and clap push-up compared to the other variations (P<.001). The clap push-up had significantly more elbow displacement than the other variations (P<.001) while hand separation was not significantly different between variations (P=.129). Peak vertical ground reaction force was significantly greater for the clap push-ups than for all other variations (P< .001). Despite similar flight heights between the 11.4 cm and clap push-ups, the greater peak vertical ground reaction force and elbow displacement of the clap push-ups indicates the clap push-up is the most intense of the variations examined. Understanding the kinematic variables involved will aid in the creation of a closed chain upper-extremity plyometric progression. PMID:27182390
Elmengaard, Brian; Bechtold, Joan E.; Chen, Xinqian; Søballe, Kjeld
2013-01-01
Revision joint replacement has poorer outcomes that have been associated with poorer mechanical fixation. We investigate a new bone-sparing surgical technique that locally cracks the sclerotic bone rim formed during aseptic loosening. We inserted 16 hydroxyapatite-coated implants bilaterally in the distal femur of eight dogs, using a controlled weight-bearing experimental model that replicates important features of a typical revision setting. At 8 weeks, a control revision procedure and a crack revision procedure were performed on contralateral implants. The crack procedure used a splined tool to perform a systematic local perforation of the sclerotic bone rim of the revision cavity. After 4 weeks, the hydroxyapatite-coated implants were evaluated for mechanical fixation by a push-out test and for tissue distribution by histomorphometry. The cracking revision procedure resulted in significantly improved mechanical fixation, significantly more bone ongrowth and bone volume in the gap, and reduced fibrous tissue compared to the control revision procedure. The study demonstrates that the sclerotic bone rim prevents bone ingrowth and promotes fixation by fibrous tissue. The effect of the cracking technique may be due to improved access to the vascular compartment of the bone. The cracking technique is a simple surgical method that potentially can improve the fixation of revision implants in sclerotic regions important for obtaining the fixation critical for overall implant stability. PMID:19148940
Marta, Carlos; Marinho, Daniel A.; Costa, Aldo M.; Barbosa, Tiago M.; Marques, Mário C.
2011-01-01
The purpose of this study was to analyse the interaction between somatotype, body fat and physical activity in prepubescent children. This was a cross-sectional study design involving 312 children (160 girls, 152 boys) aged between 10 and 11.5 years old (10.8 ± 0.4 years old). Evaluation of body composition was done determining body mass index and body fat by means of skin-fold measurements, using the method described by Slaughter. Somatotype was computed according to the Carter’s method. Physical activity was assessed with the Baecke questionnaire. The physical activity assessment employed sets of curl-ups, push-ups, standing broad jump, medicine ball throw, handgrip strength and Margaria-Kalamen power stair. There were negative associations for body fat, endomorphy and mesomorphy with curl-ups, push-ups and broad jump tests and positive associations with ball throw, handgrip strength and Margaria-Kalamen power tests. The associations for ectomorphy were the inverse of those for endomorphy and mesomorphy. Non obese children presented higher values for curl-ups, push-ups and standing broad jump. In medicine ball throw, handgrip strength and Margaria-Kalamen power test obese children presented higher scores, followed by children who were overweight. The mesoectomorphic boys and ectomesomorphic girls performed higher in all tests. The morphological typology presented more interactions with strength than % of body fat and physical activity. These data seem to suggest that the presence/absence of certain physical characteristics is crucial in the levels of motor provision in prepubescent children. PMID:23486278
Muscular contribution to low-back loading and stiffness during standard and suspended push-ups.
Beach, Tyson A C; Howarth, Samuel J; Callaghan, Jack P
2008-06-01
Push-up exercises are normally performed to challenge muscles that span upper extremity joints. However, it is also recognized that push-ups provide an effective abdominal muscle challenge, especially when the hands are in contact with a labile support surface. The purpose of this study was to compare trunk muscle activation levels and resultant intervertebral joint (IVJ) loading when standard and suspended push-ups were performed, and to quantify and compare the contribution of trunk muscles to IVJ rotational stiffness in both exercises. Eleven recreationally trained male volunteers performed sets of standard and suspended push-ups. Upper body kinematic, kinetic, and EMG data were collected and input into a 3D biomechanical model of the lumbar torso to quantify lumbar IVJ loading and the contributions of trunk muscles to IVJ rotational stiffness. When performing suspended push-ups, muscles of the abdominal wall and the latissimus dorsi were activated to levels that were significantly greater than those elicited when performing standard push-ups (p<.05). As a direct result of these increased activation levels, model-predicted muscle forces increased and consequently led to significantly greater mean (p=.0008) and peak (p=.0012) lumbar IVJ compressive forces when performing suspended push-ups. Also directly resulting from the increased activation levels of the abdominal muscles and the latissimus dorsi during suspended push-ups was increased muscular contribution to lumbar IVJ rotational stiffness (p<.05). In comparison to the standard version of the exercise, suspended push-ups appear to provide a superior abdominal muscle challenge. However, for individuals unable to tolerate high lumbar IVJ compressive loads, potential benefits gained by incorporating suspended push-ups into their resistance training regimen may be outweighed by the risk of overloading low-back tissues.
Shoulder Muscle Activation Levels During the Push-Up-Plus Exercise on Stable and Unstable Surfaces.
Torres, Rafaela J B; Pirauá, André L T; Nascimento, Vinícius Y S; Dos Santos, Priscila S; Beltrão, Natália B; de Oliveira, Valéria M A; Pitangui, Ana Carolina R; de Araújo, Rodrigo C
2017-07-01
The aim of this study was to evaluate the acute effect of the use of stable and unstable surfaces on electromyography (EMG) activity and coactivation of the scapular and upper-limb muscles during the push-up plus (with full protraction of the scapula). Muscle activation of anterior deltoid (AD), posterior deltoid (PD), pectoralis major, biceps brachii (BB), triceps brachii (TB), upper trapezius (UT), middle trapezius (MT), lower trapezius (LT), and serratus anterior (SA) levels and coactivation index were determined by surface EMG in 20 young men during push-up plus performed on a stable and unstable condition (2 unstable devices applied to hands and feet). The paired t test and Cohen d were used for statistical analysis. The results showed that during the execution of the push-up plus on the unstable surface an increased EMG activity of the scapular stabilizing muscles (SA, MT, and LT) was observed, while AD and PD muscles showed a decrease. During exercise execution on the unstable surface there was a higher index of coactivation of the scapular muscles (SA-MT and UT-LT pairs). No significant differences were observed in TB-BB and AD-PD pairs. These results suggest that the push-up-plus exercise associated with unstable surfaces produced greater EMG activity levels and coactivation index of the scapular stabilizing muscle. On the other hand, the use of an unstable surface does not promote the same effect for the shoulder muscles.
Bench press and push-up at comparable levels of muscle activity results in similar strength gains.
Calatayud, Joaquin; Borreani, Sebastien; Colado, Juan C; Martin, Fernando; Tella, Victor; Andersen, Lars L
2015-01-01
Electromyography (EMG) exercise evaluation is commonly used to measure the intensity of muscle contraction. Although researchers assume that biomechanically comparable resistance exercises with similar high EMG levels will produce similar strength gains over the long term, no studies have actually corroborated this hypothesis. This study evaluated EMG levels during 6 repetition maximum (6RM) bench press and push-up, and subsequently performed a 5-week training period where subjects were randomly divided into 3 groups (i.e., 6RM bench press group, 6RM elastic band push-up group, or control group) to evaluate muscle strength gains. Thirty university students with advanced resistance training experience participated in the 2-part study. During the training period, exercises were performed using the same loads and variables that were used during the EMG data collection. At baseline, EMG amplitude showed no significant difference between 6RM bench press and band push-up. Significant differences among the groups were found for percent change (Δ) between pretest and posttest for 6RM (p = 0.017) and for 1 repetition maximum (1RM) (p < 0.001). Six repetition maximum bench press group and 6RM elastic band push-up group improved their 1RM and 6RM (Δ ranging from 13.65 to 22.21) tests significantly with similar gains, whereas control group remains unchanged. Thus, when the EMG values are comparable and the same conditions are reproduced, the aforementioned exercises can provide similar muscle strength gains.
Masaki, Mitsuhiro; Ikezoe, Tome; Kamiya, Midori; Araki, Kojiro; Isono, Ryo; Kato, Takehiro; Kusano, Ken; Tanaka, Masayo; Sato, Syunsuke; Hirono, Tetsuya; Kita, Kiyoshi; Tsuboyama, Tadao; Ichihashi, Noriaki
2018-04-19
This study aimed to examine the association of independence in ADL with the loads during step ascent motion and other motor functions in 32 nursing home-residing elderly individuals. Independence in ADL was assessed by using the functional independence measure (FIM). The loads at the upper (i.e., pulling up) and lower (i.e., pushing up) levels during step ascent task was measured on a step ascent platform. Hip extensor, knee extensor, plantar flexor muscle, and quadriceps setting strengths; lower extremity agility using the stepping test; and hip and knee joint pain severities were measured. One-legged stance and functional reach distance for balance, and maximal walking speed, timed up-and-go (TUG) time, five-chair-stand time, and step ascent time were also measured to assess mobility. Stepwise regression analysis revealed that the load at pushing up during step ascent motion and TUG time were significant and independent determinants of FIM score. FIM score decreased with decreased the load at pushing up and increased TUG time. The study results suggest that depending on task specificity, both one step up task's push up peak load during step ascent motion and TUG, can partially explain ADL's FIM score in the nursing home-residing elderly individuals. Lower extremity muscle strength, agility, pain or balance measures did not add to the prediction.
Access to Care for Transgender Veterans in the Veterans Health Administration: 2006–2013
Shipherd, Jillian C.; Lindsay, Jan; Blosnich, John R.; Brown, George R.; Jones, Kenneth T.
2014-01-01
A 2011 Veterans Health Administration directive mandated medically necessary care for transgender veterans. Internal education efforts informed staff of the directive and promoted greater access to care. For fiscal years 2006 through 2013, we identified 2662 unique individuals with International Classification of Diseases, Ninth Revision diagnoses related to transgender status in Veterans Health Administration medical records, with 40% of new cases in the 2 years following the directive. A bottom-up push for services by veterans and top-down education likely worked synergistically to speed implementation of the new policy and increase access to care. PMID:25100417
Access to care for transgender veterans in the Veterans Health Administration: 2006-2013.
Kauth, Michael R; Shipherd, Jillian C; Lindsay, Jan; Blosnich, John R; Brown, George R; Jones, Kenneth T
2014-09-01
A 2011 Veterans Health Administration directive mandated medically necessary care for transgender veterans. Internal education efforts informed staff of the directive and promoted greater access to care. For fiscal years 2006 through 2013, we identified 2662 unique individuals with International Classification of Diseases, Ninth Revision diagnoses related to transgender status in Veterans Health Administration medical records, with 40% of new cases in the 2 years following the directive. A bottom-up push for services by veterans and top-down education likely worked synergistically to speed implementation of the new policy and increase access to care.
Effects of Different Relative Loads on Power Performance During the Ballistic Push-up.
Wang, Ran; Hoffman, Jay R; Sadres, Eliahu; Bartolomei, Sandro; Muddle, Tyler W D; Fukuda, David H; Stout, Jeffrey R
2017-12-01
Wang, R, Hoffman, JR, Sadres, E, Bartolomei, S, Muddle, TWD, Fukuda, DH, and Stout, JR. Effects of different relative loads on power performance during the ballistic push-up. J Strength Cond Res 31(12): 3411-3416, 2017-The purpose of this investigation was to examine the effect of load on force and power performance during a ballistic push-up. Sixty (24.5 ± 4.3 years, 1.75 ± 0.07 m, and 80.8 ± 13.5 kg) recreationally active men who participated in this investigation completed all testing and were included in the data analysis. All participants were required to perform a 1 repetition maximum bench press, and ballistic push-ups without external load (T1), with 10% (T2) and 20% (T3) of their body mass. Ballistic push-ups during T2 and T3 were performed using a weight loaded vest. Peak and mean force, power, as well as net impulse and flight time were determined for each ballistic push-up. Peak and mean force were both significantly greater (p < 0.01) during T3 (1,062 ± 202 and 901 ± 154 N, respectively), than both T2 (1,017 ± 202 and 842 ± 151 N, respectively) and T1 (960 ± 188 and 792 ± 140 N, respectively). Peak and mean power were significantly greater (p < 0.01) during T1 (950 ± 257 and 521 ± 148 W, respectively), than both T2 (872 ± 246 and 485 ± 143 W, respectively) and T3 (814 ± 275 and 485 ± 162 W, respectively). Peak and mean power were greatest during T1, regardless of participants' strength levels. Significant (p < 0.01) greater net impulse and smaller peak velocity and flight time were also noted from T1 to T3. Results of this investigation indicated that maximal power outputs were achieved without the use of an external load when performing the ballistic push-up, regardless of the participants' level of strength.
Shoulder kinematics during the wall push-up plus exercise.
Lunden, Jason B; Braman, Jonathan P; Laprade, Robert F; Ludewig, Paula M
2010-03-01
The push-up plus exercise is a common therapeutic exercise for improving shoulder function and treating shoulder pathology. To date, the kinematics of the push-up plus exercise have not been studied. Our hypothesis was that the wall push-up plus exercise would demonstrate increased scapular internal rotation and increased humeral anterior translation during the plus phase of the exercise, thereby potentially impacting the subacromial space. Bone pins were inserted in the humerus and scapula in 12 healthy volunteers with no history of shoulder pathology. In vivo motion during the wall push-up plus exercise was tracked using an electromagnetic tracking system. During the wall push-up plus exercise, from a starting position to the push-up plus position, there was a significant increase in scapular downward rotation (P < .05) and internal rotation (P < .05). The pattern of glenohumeral motion was humeral elevation (P < .05) and movement anterior to the scapular plane (P < .05), with humeral external rotation remaining relatively constant. We found that during a wall push-up plus exercise in healthy volunteers, the scapula was placed in a position potentially associated with shoulder impingement. Because of the shoulder kinematics of the wall push-up plus exercise, utilization of this exercise without modification early on in shoulder rehabilitation, especially in patients with subacromial impingement, should be considered cautiously. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.
Dhahbi, Wissem; Chaouachi, Anis; Dhahbi, Anis Ben; Cochrane, Jodie; Chèze, Laurence; Burnett, Angus; Chamari, Karim
2017-02-01
To examine differences between ground-reaction-force (GRF)-based parameters collected from 5 types of plyometric push-ups. Between-trials reliability and the relationships between parameters were also assessed. Thirty-seven highly active commando soldiers performed 3 trials of 5 variations of the plyometric push-up in a counterbalanced order: standard countermovement push-up (SCPu), standard squat push-up (SSPu), kneeling countermovement push-up (KCPu), kneeling squat push-up (KSPu), and drop-fall push-up (DFPu). Vertical GRF was measured during these exercises using a portable Kistler force plate. The GRF applied by the hands in the starting position (initial force supported), peak GRF and rate of force development during takeoff, flight time, impact force, and rate of force development impact on landing were determined. During standard-position exercises (SCPu and SSPu) the initial force supported and impact force were higher (P < .001) than with kneeling exercises (KCPu, KSPu, and DFPu). The peak GRF and rate of force development during takeoff were higher (P < .001) in the countermovement push-up exercises ([CMP] SCPu, KCPu, and DFPu) than squat push-up exercises ([SP] SSPu and KSPu). Furthermore, the flight time was greater (P < .001) during kneeling exercises than during standard-position exercises. A significant relationship (P < .01) between impact force and the rate of force development impact was observed for CMP and SP exercises (r = .83 and r = .62, respectively). The initial force supported was also negatively related (P < .01) to the flight time for both CMP and SP (r = -.74 and r = -.80, respectively). It was revealed that the initial force supported and the peak GRF during takeoff had excellent reliability; however, other parameters had poor absolute reliability. It is possible to adjust the intensity of plyometric push-up exercises and train athletes' muscle power by correctly interpreting GRF-based parameters. However, caution is required as some parameters had marginal absolute reliability.
Crawley, Amy A; Sherman, Ross A; Crawley, William R; Cosio-Lima, Ludmila M
2016-05-01
Police academies traditionally emphasize the importance of being physically fit. The purpose of this research was to determine cadet baseline physical fitness characteristics and assess effectiveness of a 16-week training program. Sixty-eight cadets (61 men, 7 women) volunteered to have baseline physical fitness characteristics assessed, and 55 cadets (49 men, 6 women) completed further testing at weeks 8 and 16. The testing comprised hand grip (strength), arm crank (upper-body power), 30 seconds Wingate (lower body power), sum of skinfolds and percentage body fat (body composition), 40-yard dash (sprint speed), 1 repetition maximum bench press (strength), T-test (agility), and sit-and-reach (flexibility). In addition, cadets completed standardized state testing (push-ups, sit-ups, vertical jump, and half-mile shuttle run). The training program consisted of 1 hour sessions, 3 d·wk, including aerobic, plyometrics, body weight, and resistance exercise. Significant changes were found in agility (p < 0.01), upper-body and lower-body peak power (p ≤ 0.05), sit-ups (p < 0.01), push-ups (p ≤ 0.05) across the first 8 weeks, and in agility (p ≤ 0.05), lower-body peak power (p ≤ 0.05), sit-ups (p < 0.01), push-ups (p ≤ 0.05), half-mile shuttle run (p < 0.01) across the full 16 weeks. However, none of the variables showed significant change across the second half of the program (weeks 8-16). A number of individual parameters of physical fitness showed evidence of improvement in the first 8 weeks, whereas none of the variables showed significant improvement in the second 8 weeks. This suggests modifications could be made to increase overall effectiveness of cadet physical training specifically after the 8-week mark.
Suprak, David N; Dawes, Jay; Stephenson, Mark D
2011-02-01
The push-up is a popular upper-extremity weight-bearing exercise. However, limited information is available regarding its effectiveness. Much of the past research has focused on muscle activation levels, whereas very little has examined the forces encountered during push-up variants. The purpose of the present study was to examine the effect of position within the range of motion on the percentage of body mass (BM) supported by the upper extremities during the traditional and modified (knees-down) push-up. Twenty-eight highly strength-trained male subjects were positioned with their hands on a force platform in 4 static positions, consisting of the up and down position in both the traditional and modified push-up exercise. The performance measures included the average vertical ground reaction force (GRF), expressed as a percentage of BM, supported in each of the 4 static positions and the percentage of change between the up and down positions in each push-up exercise. In both the traditional and modified push-ups, subjects supported less weight in the up vs. the down position. The percentage change in % BM from the up to the down position was greater in the modified push-up variant. The pattern of resistances to the push-up exercises observed in this study may be a result of differing moment arms between the support surface contact point (knees or feet) and the hands. These results may be useful in prescribing programs for strengthening and/or rehabilitation for both the prime movers and stabilizers of the upper extremity. Further, range of motion may need to be altered to accommodate strength differences in beginners and clients rehabilitating from injury.
Muscle Activity Patterns Do Not Differ Between Push-Up and Bench Press Exercises.
Gottschall, Jinger S; Hastings, Bryce; Becker, Zachary
2018-05-29
Popular topics for upper body resistance training involve the differences between hand positions, open versus closed chain exercises, and movement variations for the novice to the advanced. We hypothesized that there will be no difference between closed (push-up) versus open (bench press) chain exercises for the primary muscle group activity nor would there be a difference between push-ups on the toes versus knees with respect to the percent contribution of each muscle. We measured surface muscle activity of 8 upper body and core muscles during a sequence of push-up and bench press variations with a normalized weight for twelve active men. Each participant completed push-ups and bench press exercises at each of three hand positions. Our results demonstrated that there were few differences between closed versus open chain exercises for the primary muscle groups with the exception of core activation. To add, in general, narrow hand positions yielded greater activation and there were no significant differences between push-ups on the toes versus knees with respect to the percent contribution for the primary muscle groups. To sum, closed chain exercises may be preferred for functional training and knee push-ups may be ideal as a novice push-up variation.
Effect of the push-up exercise at different palmar width on muscle activities.
Kim, You-Sin; Kim, Do-Yeon; Ha, Min-Seong
2016-01-01
[Purpose] The purpose of the present study was to determine the effects of changes in palmar width on the muscle activities of the shoulder and truncus muscles during push-up exercise. [Subjects] Twelve healthy adult males participated in this study as subjects. [Methods] Push-up exercises were performed with three different palmar width in narrow (50%), neutral (100%), and wide positions (150%). We measured the muscle activities of the deltoideus p. acromialis, pectoralis minor, pectoralis major, serratus anterior, biceps brachii, triceps brachii, latissimus dorsi, and infraspinatus. [Results] Pectoralis minor, triceps brachii, and infraspinatus muscle activities were greater during push-ups performed with the 50% palmar width compared with the other palmar widths. Pectoralis major muscle activity was greater during push-ups performed with the 50% and 100% palmar widths compared with the 150% palmar width. Serratus anterior muscle activity was greater during push-ups performed with the 150% palmar width compared with the other palmar widths. [Conclusion] These results are expected to serve as reference materials for push-up exercise applications in training programs for truncus muscle strengthening or rehabilitation programs for scapula patients.
Quantifying muscle patterns and spine load during various forms of the push-up.
Freeman, Stephanie; Karpowicz, Amy; Gray, John; McGill, Stuart
2006-03-01
This study was conducted to quantify the normalized amplitudes of the abdominal wall and back extensor musculature during a variety of push-up styles. We also sought to quantify their impact on spinal loading by calculating spinal compression and torque generation in the L4-5 area. Ten university-age participants, nine males and one female, in good to excellent condition, volunteered to participate in this study. All participants were requested to perform a maximum of 12 different push-up exercises, three trials per exercise. Surface electromyographic data (EMG) were collected bilaterally on rectus abdominis, external oblique, internal oblique, latissimus dorsi, and erector spinae muscles, and unilaterally (right side) on pectoralis major, triceps brachii, biceps brachii, and anterior deltoid muscles. Spine kinetics were obtained using an anatomically detailed model of the torso/spine. This study revealed that more dynamic push-ups (i.e., ballistic, with hand movement) required more muscle activation and higher spine load, whereas placing labile balls under the hands only resulted in modest increases in spine load. Right rectus abdominis (RA) activation was significantly higher than left RA activation during the left hand forward push-up and vice versa for the right hand forward push-up (P < 0.001). External oblique (EO) demonstrated the same switch in dominance during staggered hand push-ups (P < 0.01). The one-arm push-up resulted in the highest spine compression. Skilled participants showed greater synchronicity with peak muscle activation (plyometric type of contractions) during ballistic push-ups. These data will help guide exercise selection for individuals with differing training objectives and injury history.
Sanders, Martha J; Reynolds, Jesse; Bagatell, Nancy; Treu, Judith A; OʼConnor, Edward; Katz, David L
2015-01-01
The purpose of the study was to examine the efficacy of a multidisciplinary train-the-trainer model for improving fitness and food label literacy in third-grade students. University student trainers taught ABC for Fitness and Nutrition Detectives, established programs to promote physical activity and nutrition knowledge, to 239 third-grade students in 2 communities over a 6-month period. A total of 110 children were in the intervention group and 129 children in the control group (2 schools each). Outcomes included the Food Label Literacy and Nutrition Knowledge test and the fitness measures of curl-ups, push-ups, 0.5-mile run, and sit and reach. Focus groups were conducted as process feedback. Four public schools in 2 different communities. A total of 200 third-grade students. ABC for Fitness and Nutrition Detectives. Food Label Literacy and Nutrition Knowledge test and the fitness measures of curl-ups, push-ups, 0.5-mile run, and sit and reach. Nutrition knowledge increased in the intervention group by 25.2% (P < .01). Fitness measures in the intervention schools showed greater improvement than those in the controls for curl-ups (P < .01), push-ups (P < .01), sit and reach left (P = .07), and 0.5-mile run (P = .06). Process feedback from 3 teachers and 60 students indicated satisfaction with the program. Adaptation of the train-the-trainer approach for Nutrition Detectives and ABC for Fitness was effective for delivering these health-related programs.
Muscular activities during sling- and ground-based push-up exercise.
Maeo, Sumiaki; Chou, Tatsuya; Yamamoto, Masayoshi; Kanehisa, Hiroaki
2014-03-28
This study aimed to clarify the characteristics of muscle activities during push-up exercises performed under sling condition by comparison with those performed under ground condition. We hypothesized that sling-based push-ups induce higher muscle activities than the ground-based push-ups, and its effects are more prominent in dynamic compared to static exercise owing to increased demands of stabilization. Twenty young males performed sling- and ground-based push-ups in each of static (maintaining the posture with the elbow joint angle at 90 deg) and dynamic (repeating push-ups at a rate of 45 per minute) exercises. Surface electromyograms (EMGs) of the pectoralis major, latissimus dorsi, triceps brachii, biceps brachii, rectus abdominis, external oblique, internal oblique, and erector spinae muscles were recorded during the exercises. The EMG data were normalized to those obtained during maximal voluntary contraction of each muscle (% EMGmax). In the static exercise, sling condition showed significantly higher % EMGmax values than the ground condition in the triceps brachii (+27%: relative to ground condition) and biceps brachii (+128%) as well as the three abdominal muscles (+15% to +27%). In the dynamic exercise, such condition-related differences were more prominent and those in the pectoralis major (+29%) in addition to the aforementioned five muscles (+19% to +144%) were significant. These results supported the hypothesis and indicate that sling-based push-up exercise can provide greater activation in upper limb and anterior trunk muscles than the ground-based push-up exercise.
Muscular activities during sling- and ground-based push-up exercise
2014-01-01
Background This study aimed to clarify the characteristics of muscle activities during push-up exercises performed under sling condition by comparison with those performed under ground condition. We hypothesized that sling-based push-ups induce higher muscle activities than the ground-based push-ups, and its effects are more prominent in dynamic compared to static exercise owing to increased demands of stabilization. Findings Twenty young males performed sling- and ground-based push-ups in each of static (maintaining the posture with the elbow joint angle at 90 deg) and dynamic (repeating push-ups at a rate of 45 per minute) exercises. Surface electromyograms (EMGs) of the pectoralis major, latissimus dorsi, triceps brachii, biceps brachii, rectus abdominis, external oblique, internal oblique, and erector spinae muscles were recorded during the exercises. The EMG data were normalized to those obtained during maximal voluntary contraction of each muscle (% EMGmax). In the static exercise, sling condition showed significantly higher % EMGmax values than the ground condition in the triceps brachii (+27%: relative to ground condition) and biceps brachii (+128%) as well as the three abdominal muscles (+15% to +27%). In the dynamic exercise, such condition-related differences were more prominent and those in the pectoralis major (+29%) in addition to the aforementioned five muscles (+19% to +144%) were significant. Conclusion These results supported the hypothesis and indicate that sling-based push-up exercise can provide greater activation in upper limb and anterior trunk muscles than the ground-based push-up exercise. PMID:24678968
Mechanical and energetic consequences of reduced ankle plantar-flexion in human walking
Huang, Tzu-wei P.; Shorter, Kenneth A.; Adamczyk, Peter G.; Kuo, Arthur D.
2015-01-01
ABSTRACT The human ankle produces a large burst of ‘push-off’ mechanical power late in the stance phase of walking, reduction of which leads to considerably poorer energy economy. It is, however, uncertain whether the energetic penalty results from poorer efficiency when the other leg joints substitute for the ankle's push-off work, or from a higher overall demand for work due to some fundamental feature of push-off. Here, we show that greater metabolic energy expenditure is indeed explained by a greater demand for work. This is predicted by a simple model of walking on pendulum-like legs, because proper push-off reduces collision losses from the leading leg. We tested this by experimentally restricting ankle push-off bilaterally in healthy adults (N=8) walking on a treadmill at 1.4 m s−1, using ankle–foot orthoses with steel cables limiting motion. These produced up to ∼50% reduction in ankle push-off power and work, resulting in up to ∼50% greater net metabolic power expenditure to walk at the same speed. For each 1 J reduction in ankle work, we observed 0.6 J more dissipative collision work by the other leg, 1.3 J more positive work from the leg joints overall, and 3.94 J more metabolic energy expended. Loss of ankle push-off required more positive work elsewhere to maintain walking speed; this additional work was performed by the knee, apparently at reasonably high efficiency. Ankle push-off may contribute to walking economy by reducing dissipative collision losses and thus overall work demand. PMID:26385330
Mechanical and energetic consequences of reduced ankle plantar-flexion in human walking.
Huang, Tzu-wei P; Shorter, Kenneth A; Adamczyk, Peter G; Kuo, Arthur D
2015-11-01
The human ankle produces a large burst of 'push-off' mechanical power late in the stance phase of walking, reduction of which leads to considerably poorer energy economy. It is, however, uncertain whether the energetic penalty results from poorer efficiency when the other leg joints substitute for the ankle's push-off work, or from a higher overall demand for work due to some fundamental feature of push-off. Here, we show that greater metabolic energy expenditure is indeed explained by a greater demand for work. This is predicted by a simple model of walking on pendulum-like legs, because proper push-off reduces collision losses from the leading leg. We tested this by experimentally restricting ankle push-off bilaterally in healthy adults (N=8) walking on a treadmill at 1.4 m s(-1), using ankle-foot orthoses with steel cables limiting motion. These produced up to ∼50% reduction in ankle push-off power and work, resulting in up to ∼50% greater net metabolic power expenditure to walk at the same speed. For each 1 J reduction in ankle work, we observed 0.6 J more dissipative collision work by the other leg, 1.3 J more positive work from the leg joints overall, and 3.94 J more metabolic energy expended. Loss of ankle push-off required more positive work elsewhere to maintain walking speed; this additional work was performed by the knee, apparently at reasonably high efficiency. Ankle push-off may contribute to walking economy by reducing dissipative collision losses and thus overall work demand. © 2015. Published by The Company of Biologists Ltd.
Sherman, Ross A.; Crawley, William R.; Cosio-Lima, Ludmila M.
2016-01-01
Abstract Crawley, AA, Sherman, RA, Crawley, WR, and Cosio-Lima, LM. Physical fitness of police academy cadets: baseline characteristics and changes during a 16-week academy. J Strength Cond Res 30(5): 1416–1424, 2016—Police academies traditionally emphasize the importance of being physically fit. The purpose of this research was to determine cadet baseline physical fitness characteristics and assess effectiveness of a 16-week training program. Sixty-eight cadets (61 men, 7 women) volunteered to have baseline physical fitness characteristics assessed, and 55 cadets (49 men, 6 women) completed further testing at weeks 8 and 16. The testing comprised hand grip (strength), arm crank (upper-body power), 30 seconds Wingate (lower body power), sum of skinfolds and percentage body fat (body composition), 40-yard dash (sprint speed), 1 repetition maximum bench press (strength), T-test (agility), and sit-and-reach (flexibility). In addition, cadets completed standardized state testing (push-ups, sit-ups, vertical jump, and half-mile shuttle run). The training program consisted of 1 hour sessions, 3 d·wk−1, including aerobic, plyometrics, body weight, and resistance exercise. Significant changes were found in agility (p < 0.01), upper-body and lower-body peak power (p ≤ 0.05), sit-ups (p < 0.01), push-ups (p ≤ 0.05) across the first 8 weeks, and in agility (p ≤ 0.05), lower-body peak power (p ≤ 0.05), sit-ups (p < 0.01), push-ups (p ≤ 0.05), half-mile shuttle run (p < 0.01) across the full 16 weeks. However, none of the variables showed significant change across the second half of the program (weeks 8–16). A number of individual parameters of physical fitness showed evidence of improvement in the first 8 weeks, whereas none of the variables showed significant improvement in the second 8 weeks. This suggests modifications could be made to increase overall effectiveness of cadet physical training specifically after the 8-week mark. PMID:26466133
Evaluation of bond strength of various epoxy resin based sealers in oval shaped root canals.
Cakici, Fatih; Cakici, Elif Bahar; Ceyhanli, Kadir Tolga; Celik, Ersan; Kucukekenci, Funda Fundaoglu; Gunseren, Arif Onur
2016-09-30
The aim of this study was to evaluate the bond strength of AH plus, Acroseal, and Adseal to the root canal dentin. A total of 36 single-rooted, mandibular premolar teeth were used. Root canal shaping procedures were performed with ProTaper rotary instruments (Dentsply Maillefer) up to size F4. The prepared samples were then randomly assembled into 3 groups (n = 12). For each group, an ultrasonic tip (size 15, 0.02 taper) which was also coated with an epoxy resin based sealer and placed 2 mm shorter than the working length. The sealer was then activated for 10 s. A push-out test was used to measure the bond strength between the root canal dentine and the sealer. Kruskal-Wallis test to evaluate the push-out bond strength of epoxy based sealer (P = 0.05). The failure mode data were statistically analyzed using Pearson's chi square test (P = 0.05). Kruskal-Wallis test indicated that there were no statistically significant difference among the push out bond strength values of 3 mm (p = 0.123) and 6 mm (P = 0.057) for groups, there was statistically significant difference push out bond strength value of 9 mm (P = 0.032). Pearson's chi square test showed statistically significant differences for the failure types among the groups. Various epoxy resin based sealers activated ultrasonically showed similar bond strength in oval shaped root canals. Apical sections for all groups have higher push out bond strength values than middle and coronal sections.
Push-Pull Locomotion for Vehicle Extrication
NASA Technical Reports Server (NTRS)
Creager, Colin M.; Johnson, Kyle A.; Plant, Mark; Moreland, Scott J.; Skonieczny, Krzysztof
2014-01-01
For applications in which unmanned vehicles must traverse unfamiliar terrain, there often exists the risk of vehicle entrapment. Typically, this risk can be reduced by using feedback from on-board sensors that assess the terrain. This work addressed the situations where a vehicle has already become immobilized or the desired route cannot be traversed using conventional rolling. Specifically, the focus was on using push-pull locomotion in high sinkage granular material. Push-pull locomotion is an alternative mode of travel that generates thrust through articulated motion, using vehicle components as anchors to push or pull against. It has been revealed through previous research that push-pull locomotion has the capacity for generating higher net traction forces than rolling, and a unique optical flow technique indicated that this is the result of a more efficient soil shearing method. It has now been found that pushpull locomotion results in less sinkage, lower travel reduction, and better power efficiency in high sinkage material as compared to rolling. Even when starting from an "entrapped" condition, push-pull locomotion was able to extricate the test vehicle. It is the authors' recommendation that push-pull locomotion be considered as a reliable back-up mode of travel for applications where terrain entrapment is a possibility.
Calatayud, Joaquin; Vinstrup, Jonas; Jakobsen, Markus D; Sundstrup, Emil; Colado, Juan Carlos; Andersen, Lars L
2017-07-01
To investigate the effect of different attentional focus conditions on muscle activity during the push-up exercise and to assess the possible influence of muscle strength and training experience. Eighteen resistance-trained men performed 1RM bench press testing and were familiarized with the procedure during the first session. In the second session, three different conditions were randomly performed: regular push-up and push-up focusing on using the pectoralis major and triceps brachii muscles, respectively. Surface electromyography (EMG) was recorded and analyzed (EMG normalized to max; nEMG) for the triceps brachii and pectoralis major muscles. Participants had on average 8 (SD 6) years of training experience and 1RM of 1.25 (SD 0.28) kg per kg bodyweight. Focusing on using pectoralis major increased activity in this muscle by 9% nEMG (95% CI 5-13; Cohen's d 0.60) compared with the regular condition. Triceps activity was not significantly influenced by triceps focus although borderline significant, with a mean difference of 5% nEMG (95% CI 0-10; Cohen's d 0.30). However, years of training experience was positively associated with the ability to selectively activate the triceps (β = 0.41, P = 0.04), but not the pectoralis. Bench press 1RM was not significantly associated with the ability to selectively activate the muscles. Pectoralis activity can be increased when focusing on using this muscle during push-ups, whereas the ability to do this for the triceps is dependent on years of training experience. Maximal muscle strength does not appear to be a decisive factor for the ability to selectively activate these muscles.
Sandhu, Jaspal S; Mahajan, Shruti; Shenoy, Shweta
2008-04-01
Numerous exercises are used to strengthen muscles around the shoulder joint including the push-up and the push-up plus. An important consideration is the addition of surface instability in the form of swiss ball for rehabilitation and strength. The justification for the use of the swiss ball is based on its potential for increasing muscular demand required to maintain postural stability and for improving joint proprioception. Evidence for this is lacking in literature. To compare the myoelectric amplitude of shoulder muscles during push-ups on labile and stable surface. Same subject experimental study. Thirty healthy male subjects in the age group 20-30 years with a mean height of 173.65 cm (+/- SD 2.56) and a mean weight of 69.9 kg (+/-SD 0.2) were taken. Surface electromyogram was recorded from triceps, pectoralis major, serratus anterior and upper trapezius while performing push-up and push-up plus exercises, both on labile and stable surface. Significant increase in muscle activity was observed in pectoralis major and triceps muscle (only during eccentric phase of elbow pushups), while serratus anterior and upper trapezius showed no change in activation level on swiss ball. The addition of a swiss ball is capable of influencing shoulder muscle activity during push-up variations, although the effect is task and muscle dependent.
Interfacial stress state present in a 'thin-slice' fibre push-out test
NASA Technical Reports Server (NTRS)
Kallas, M. N.; Koss, D. A.; Hahn, H. T.; Hellmann, J. R.
1992-01-01
An analysis of the stress distributions along the fiber-matrix interface in a 'thin-slice' fiber push-out test is presented for selected test geometries. For the small specimen thicknesses often required to displace large-diameter fibers with high interfacial shear strengths, finite element analysis indicates that large bending stresses may be present. The magnitude of these stresses and their spatial distribution can be very sensitive to the test configuration. For certain test geometries, the specimen configuration itself may alter the interfacial failure process from one which initiates due to a maximum in shear stress near the top surface adjacent to the indentor, to one which involves mixed mode crack growth up from the bottom surface and/or yielding within the matrix near the interface.
Physical fitness and physical training during Norwegian military service.
Dyrstad, Sindre M; Soltvedt, Rune; Hallén, Jostein
2006-08-01
Evaluate the physical fitness and training of Norwegian infantry soldiers during 10 months of compulsory military service. Maximal oxygen uptake (VO2max) and maximal numbers of sit-ups, push-ups, and chin-ups and 3-km running time were tested in 107 male infantry soldiers at the beginning and end of basic training (BT), and again at demobilization. The amount of physical training was registered throughout the military service. During BT, major improvements in sit-ups and push-ups were found. VO2max increased in soldiers with the lowest initial VO2max, but decreased to pre-BT level at demobilization. The amount of obligatory physical training was 8.5 hours x week(-1) during BT and 35% lower after BT, and was usually performed in uniform at low to moderate intensity. The amount of high-intensity endurance and strength training during compulsory military service is to low to improve the soldiers' endurance and muscular strength.
Recovery in Level 7-10 Women's USA Artistic Gymnastics.
Buckner, Stephen B; Bacon, Nicholas T; Bishop, Phillip A
2017-01-01
This study assessed physical performance in women's artistic gymnastics following three variable recovery periods. Participants included fifteen female gymnasts (mean age = 13.5 ± 1.1) who had competed at USA Gymnastics (USAG) levels 7 - 10 within at least one year prior to the study. Each testing session consisted of a warm-up followed by four muscular endurance tests and one explosive maximal test. Assessments included pull-ups, leg lifts, handstand push-ups, vertical jump, and push-ups. After the performance assessments, the participants completed a typical practice session. The performance measures were reassessed at the beginning of each of the recovery periods of 24, 48, and 72 hours in a counterbalanced design. Performance assessments were converted into Z-scores and then averaged for a composite session Z-score. The composite session Z-scores were compared to evaluate the recovery duration. Composite Z's were significantly lower (p=0.000), after the 24 (z=-1.10) and the 48 hour (z=-0.71) recovery periods compared to baseline (z=0.00). However, there was no difference in scores (p=1.00) between the baseline and 72 hours (z=0.004) recovery. Full recovery required 72 hours under the conditions of this study.
McDonald, Cameron; Bauer, Judy; Capra, Sandra; Waterhouse, Mary
2013-01-01
Decreased lean body mass (LBM) is common in breast cancer survivors yet currently there is a lack of information regarding the determinants of LBM after treatment, in particular, the effect of physical activity and dietary factors, such as long-chain omega-3 fatty acids (LCn-3) on LBM and LBM function. This cross-sectional study explored associations of LBM and function with LCn-3 intake, dietary intake, inflammation, quality of life (QOL) and physical fitness in breast cancer survivors to improve clinical considerations when addressing body composition change. Forty-nine women who had completed treatment (surgery, radiation and/or chemotherapy) were assessed for body composition (BODPOD), LCn-3 content of erythrocytes, C-reactive protein (CRP), QOL, dietary intake, objective physical activity, 1-min push-ups, 1-min sit-stand, sub-maximal treadmill (TM) test, and handgrip strength. After adjustment for age, LBM was associated with push-ups (r = 0.343, p = 0.000), stage reached on treadmill (StageTM) (r = 0.302, 0.001), % time spent ≥ moderate activity (Mod + Vig) (r = 0.228, p = 0.024). No associations were seen between anthropometric values and any treatment, diagnostic and demographical variables. Body mass, push-ups and StageTM accounted for 76.4% of the variability in LBM (adjusted r-square: 0.764, p = 0.000). After adjustment docosahexanoic acid (DHA) was positively associated with push-ups (β=0.399, p = 0.001), eicosapentanoic acid (EPA) was negatively associated with squats (r = -0.268, p = 0.041), with no other significant interactions found between LCn-3 and physical activity for LBM or LBM function. This is the first investigation to report that a higher weight adjusted LBM is associated with higher estimated aerobic fitness and ability to perform push-ups in breast cancer survivors. Potential LCn-3 and physical activity interactions on LBM require further exploration.
Psychometric Evaluation of the Life Orientation Test-Revised in Treated Opiate Dependent Individuals
ERIC Educational Resources Information Center
Hirsch, Jameson K.; Britton, Peter C.; Conner, Kenneth R.
2010-01-01
We examined internal consistency and test-retest reliability of a measure of dispositional optimism, the Life Orientation Test-Revised, in 121 opiate-dependent patients seeking methadone treatment. Internal consistency was adequate at baseline (alpha = 0.69) and follow-up (alpha = 0.72). Low socioeconomic status and being on disability were…
Freistadt, Fernanda; Branigan, Erin; Pupp, Chris; Stefanutto, Marzio; Bambo, Carlos; Alexandre, Maria; Pinheiro, Sandro O; Ballweg, Ruth; Dgedge, Martinho; O'Malley, Gabrielle; de Oliveira, Justine Strand
2014-01-01
Mozambique, with approximately 0.4 physicians and 4.1 nurses per 10,000 people, has one of the lowest ratios of health care providers to population in the world. To rapidly scale up health care coverage, the Mozambique Ministry of Health has pushed for greater investment in training nonphysician clinicians, Tιcnicos de Medicina (TM). Based on identified gaps in TM clinical performance, the Ministry of Health requested technical assistance from the International Training and Education Center for Health (I-TECH) to revise the two-and-a-half-year preservice curriculum. A six-step process was used to revise the curriculum: (i) Conducting a task analysis, (ii) defining a new curriculum approach and selecting an integrated model of subject and competency-based education, (iii) revising and restructuring the 30-month course schedule to emphasize clinical skills, (iv) developing a detailed syllabus for each course, (v) developing content for each lesson, and (vi) evaluating implementation and integrating feedback for ongoing improvement. In May 2010, the Mozambique Minister of Health approved the revised curriculum, which is currently being implemented in 10 training institutions around the country. Key lessons learned: (i) Detailed assessment of training institutions' strengths and weaknesses should inform curriculum revision. (ii) Establishing a Technical Working Group with respected and motivated clinicians is key to promoting local buy-in and ownership. (iii) Providing ready-to-use didactic material helps to address some challenges commonly found in resource-limited settings. (iv) Comprehensive curriculum revision is an important first step toward improving the quality of training provided to health care providers in developing countries. Other aspects of implementation at training institutions and health care facilities must also be addressed to ensure that providers are adequately trained and equipped to provide quality health care services. This approach to curriculum revision and implementation teaches several key lessons, which may be applicable to preservice training programs in other less developed countries.
de Araújo, Rodrigo Cappatode; Pirauá, André Luiz Torres; Beltrão, Natália Barros; Pitangui, Ana Carolina Rodarti
2018-03-01
Scapular dyskinesis is the term used to describe changes in the positioning or movement of the scapula. Such dysfunction is associated with changes in the activation of the scapular muscles. However, the influence of the axial muscles on the scapular muscles activity of subjects with scapular dyskinesis is unknown. This study aimed to compare the electromyography (EMG) activity of periscapular muscles and its correlation with the external oblique muscle during the execution of push-up performed in different surfaces, in volunteers with and without scapular dyskinesis. Thirty-six men, divided in two groups (control and dyskinesis), performed push-up on stable and unstable surface. The EMG activity of serratus anterior (SA_5th and SA_7th fibers), upper (UT) and lower (LT) trapezius, external oblique (EO) was recorded during execution of each task condition. Statistical analyzes were performed using two way ANOVA repeated measures and Pearson correlation. It was observed effect of interaction between factors, being evidenced increased activity of UT, SA_7th and OE for the control group and decreased activity of SA_5th, SA_7th and EO for dyskinesis group during execution of push-up on unstable surface. In both groups positive correlations (r > 0.47) were observed between EMG activity of SA and EO. In the exercises tested, there seems to be an anatomical and functional relationship between the SA and EO muscles. The use of the unstable surface promotes increased neuromuscular demand, but the neuromuscular strategies appear to differ between groups.
Wong, Brett J.; Sheriff, Don D.
2008-01-01
The “push-pull” effect denotes the reduced tolerance to +Gz (hypergravity) when +Gz stress is preceded by exposure to hypogravity, i.e., fractional, zero, or negative Gz. The purpose of this study was to test the hypothesis that an exaggerated, myogenically mediated rise in leg vascular conductance contributes to the push-pull effect, using heart level arterial blood pressure as a measure of G tolerance. The approach was to impose control (30 s of 30° head-up tilt) and push-pull (30 s of 30° head-up tilt immediately preceded by 10 s of −15° head-down tilt) gravitational stress after administration of hexamethonium (5 mg/kg) to inhibit autonomic ganglionic neurotransmission in seven dogs. Cardiac output or thigh level arterial pressure (myogenic stimulus) was maintained constant by computer-controlled ventricular pacing. The animals were sedated with acepromazine and lightly restrained in lateral recumbency on a tilt table. Following the onset of head-up tilt, the magnitude of the fall in heart level arterial pressure from baseline was −11.6 ± 2.9 and −17.1 ± 2.2 mmHg for the control and push-pull trials, respectively (P < 0.05), when cardiac output was maintained constant. Over 40% of the exaggerated fall in heart level arterial pressure was attributable to an exaggerated rise in hindlimb vascular conductance (P < 0.05). Maintaining thigh level arterial pressure constant abolished the exaggerated rise in hindlimb blood flow. Thus a push-pull effect largely attributable to a myogenically induced rise in leg vascular conductance occurs when autonomic function is inhibited. PMID:18927267
Kim, Byeong-Jo; Lee, Jung-Hoon
2015-01-01
[Purpose] The aim of this study was to evaluate the effects of scapula-upward taping (SUT) in a patient with shoulder pain caused by scapular downward rotation (SDR). [Subject] A 26-year-old male with SDR experienced severe pain in the left shoulder when he lifted his left upper extremity to hold the handle in a bus and during and after push-up exercise. [Methods] The patient underwent SUT for a period of 1 month, 5 times per week, for an average of 9 h/d. [Results] The patient’s radiographs showed that the degree of SDR had decreased; the left shoulder pain also decreased in the resting state and during and after push-up exercise. The manual muscle strength test grades of the upper trapezius, lower trapezius, and serratus anterior had increased. The patient was able to lift the left upper extremity to hold the handle in a bus and perform the push-up exercise without experiencing any pain. [Conclusion] Repeated SUT application may be a beneficial treatment method for alleviating the degree of SDR and shoulder pain in SDR patients. PMID:25729213
Horsak, Brian; Kiener, Marion; Pötzelsberger, Andreas; Siragy, Tarique
2017-01-01
Push-up plus variations are commonly prescribed to clients during shoulder rehabilitation. The purpose of this study was to compare electromyographic (EMG) activities of the serratus anterior (SA), upper (UT), and lower trapezius (LT) during a knee push-up plus and knee-plus exercise performed on various surfaces. Within-subjects Repeated-Measure Design. 19 healthy, young female participants performed both exercises on a stable and unstable surface and during sling-suspension. Surface EMG activities were recorded and average amplitudes were presented as a percentage of the maximal voluntary contraction. A two-way repeated-measures ANOVA was performed to determine differences in activity for each muscle. SA showed no significant differences between exercises and was independent of the base of support (p > 0.05). Muscle activity of UT (95% CI [1.2, 1.4]) and LT (95% CI [2.4, 3.5]) showed slightly greater values when performing the knee push-up plus compared to the knee-plus exercise. The isolated protraction of the shoulder girdle in a kneeling position is as sufficient as the push-up plus in activating the SA selectively. Therefore, we recommended this exercise for clients who are unable to perform an entire push-up or should avoid detrimental stress on the shoulder joint. Copyright © 2016 Elsevier Ltd. All rights reserved.
Comparison of the effects of an eight-week push-up program using stable versus unstable surfaces.
Chulvi-Medrano, Iván; Martínez-Ballester, Esteban; Masiá-Tortosa, Laura
2012-12-01
Recently, the trend among physical training and rehabilitation professionals is the use of resistance exercise on unstable equipment in order to increase the effort of the agonist and stabilizing muscles. It is unknown if performing exercises on unstable surfaces provides a greater training stimulus as compared to training on a stable training surface. Therefore, the purpose of this research was to compare the effect that push-up training on stable and unstable surfaces had on strength performance in healthy young men. Thirty subjects with experience in resistance training participated in push-up training two days per week for eight weeks on one of three different surfaces: the floor (Tp), the T-Bow® (TBp) or the BOSU® (Bp). Strength, as measured by one repetition maximum (1-RM) and muscle endurance, as measured by number of pushups performed did not improve significantly (p>0.05) for any of the intervention groups. The addition of unstable surfaces in push-up training does not provide greater improvement in muscular strength and endurance than push up training performed on a stable surface in young men. 3b.
Angioi, Manuela; Metsios, George S; Twitchett, Emily; Koutedakis, Yiannis; Wyon, Matthew
2009-01-01
The physical demands imposed on contemporary dancers by choreographers and performance schedules make their physical fitness just as important to them as skill development. Nevertheless, it remains to be confirmed which physical fitness components are associated with aesthetic competence. The aim of this study was to: 1. replicate and test a novel aesthetic competence tool for reliability, and 2. investigate the association between selected physical fitness components and aesthetic competence by using this new tool. Seventeen volunteers underwent a series of physical fitness tests (body composition, flexibility, muscular power and endurance, and aerobic capacity) and aesthetic competence assessments (seven individual criteria commonly used by selected dance companies). Inter-rater reliability of the aesthetic competence tool was very high (r = 0.96). There were significant correlations between the aesthetic competence score and jump ability and push-ups (r = 0.55 and r = 0.55, respectively). Stepwise backward multiple regression analysis revealed that the best predictor of aesthetic competence was push-ups (R(2) = 0.30, p = 0.03). Univariate analyses also revealed that the interaction of push-ups and jump ability improved the prediction power of aesthetic competence (R(2) = 0.44, p = 0.004). It is concluded that upper body muscular endurance and jump ability best predict aesthetic competence of the present sample of contemporary dancers. Further research is required to investigate the contribution of other components of aesthetic competence, including upper body strength, lower body muscular endurance, general coordination, and static and dynamic balance.
Factors affecting the cement-post interface.
Zicari, F; De Munck, J; Scotti, R; Naert, I; Van Meerbeek, B
2012-03-01
To evaluate the effect of different factors on the push-out bond strength of glass fiber posts luted in simulated (standard) root canals using different composite cements. Three types of glass-fiber root-canal posts with a different matrix, namely an epoxy resin (RelyX post, 3M ESPE), a proprietary composite resin (FRC-Plus post, Ivoclar-Vivadent), and a methacrylate resin (GC post, GC), and three types of composite cements, namely an etch-and-rinse Bis-GMA-based (Variolink II, Ivoclar-Vivadent), a self-etch 10-MDP-based (Clearfil Esthetic Cement, Kuraray) and a self-adhesive (RelyX Unicem, 3M ESPE) cement, were tested. Posts were either left untreated (control), were treated with silane, or coated with silicated alumina particles (Cojet system, 3M ESPE). Posts were inserted up to 9-mm depth into composite CAD-CAM blocks (Paradigm, 3M ESPE) in order to solely test the strength of the cement-post interface, while excluding interference of the cement-dentin interface. After 1-week storage at 37 °C, three sections (coronal, middle, apical) of 2-mm thickness were subjected to a push-out bond-strength test. All three variables, namely the type of post, the composite cement and the post-surface pre-treatment, were found to significantly affect the push-out bond strength (p<0.001). Regarding the type of post, a significantly lower push-out bond strength was recorded for the FRC-Plus post (Ivoclar-Vivadent); regarding the composite cement, a significantly higher push-out bond strength was recorded for the self-adhesive cement Unicem (3M ESPE); and regarding the post-surface treatment, a significantly higher push-out bond strength was recorded when the post-surface was beforehand subjected to a Cojet (3M ESPE) combined sandblasting/silicatization surface pre-treatment. Many interactions between these three variables were found to be significant as well (p<0.001). Finally, the push-out bond strength was found to significantly reduce with depth from coronal to apical. Laboratory testing revealed that different variables like the type of post, the composite cement and the post-surface pre-treatment may influence the cement-post interface, making clear guidelines for routine clinical practice hard to define. Further long-term durability testing may help to clarify, and should therefore be encouraged. Copyright © 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Physical Activity Performance of Focal Middle School Students
ERIC Educational Resources Information Center
Erfle, Stephen E.; Gelbaugh, Corey M.
2013-01-01
Histograms of push-ups and curl-ups from a sample of more than 9,000 students show periodic spikes at five and 10 unit intervals. This article argues that these spikes are related to focal points, a game theoretic concept popularized by Nobel Laureate Thomas Schelling. Being focal on one test makes one more likely to be focal on the other. Focal…
Apparatus for performing high-temperature fiber push-out testing
NASA Technical Reports Server (NTRS)
Eldridge, Jeffrey I. (Inventor); Ebihara, Ben T. (Inventor)
1994-01-01
The apparatus disclosed in the present invention measures the force at which a fiber resist the motion of an indenter driven at constant speed. This apparatus conducts these test in a vacuum of about 10(exp -6) tort and at temperatures up to 1100 C. Temperature and vacuum environment are maintained while controlling indenter motion, sample position, and providing magnified visual inspection during the test.
Muneta, Takeshi; Hara, Kenji; Ju, Young-Jin; Mochizuki, Tomoyuki; Morito, Toshiyuki; Yagishita, Kazuyoshi; Sekiya, Ichiro
2010-06-01
The purpose of the study was to compare the outcome of revision anterior cruciate ligament (ACL) reconstruction by the double-bundle (DB) technique using multi-strand semitendinosus tendon with that of primary reconstruction by use of the same technique. The study included 21 patients who underwent revision ACL reconstruction (mean follow-up, 40 months) with the semitendinosus tendon DB technique between 1995 and 2006 and 86 unilateral primary DB ACL reconstructions (mean follow-up, 33 months) between 2000 and 2004. The outcome of both groups was compared based on differences between operated and unoperated limbs and modified International Knee Documentation Committee grades. Both the overall and sports-related subjective scores were evaluated between the 2 groups. The KT measurements (MEDmetric, San Diego, CA) averaged 1.7 mm (SD, 1.8 mm) in the revision group and 1.5 mm (SD, 1.6 mm) in the primary group. There was no significant difference in KT measurements between the 2 groups. The Lachman test was negative in 83% of revision cases and 87% of primary cases; the anterior drawer test was negative in 83% and 91%, respectively, and the pivot-shift test was negative in 78% and 90%, respectively. There was a tendency for a positive pivot-shift test in the revision group being higher. The Lysholm score and subjective recovery score were significantly lower in the revision group. The semitendinosus tendon DB revision procedure provided range of motion and anterior stability comparable to those after primary DB surgery and a comparable return to athletic activities. However, the patients tended to have positive pivot-shift test results. The revision cases were also inferior in terms of the general evaluation of recovery of knee condition. The outcome scores were lower overall in the revision group. Level IV, therapeutic case series. Copyright (c) 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Comparison of integrated and isolated training on performance measures and neuromuscular control.
Distefano, Lindsay J; Distefano, Michael J; Frank, Barnett S; Clark, Micheal A; Padua, Darin A
2013-04-01
Traditional weight training programs use an exercise prescription strategy that emphasizes improving muscle strength through resistance exercises. Other factors, such as stability, endurance, movement quality, power, flexibility, speed, and agility are also essential elements to improving overall functional performance. Therefore, exercises that incorporate these additional elements may be beneficial additions to traditional resistance training programs. The purpose of the study was to compare the effects of an isolated resistance training program (ISO) and an integrated training program (INT) on movement quality, vertical jump height, agility, muscle strength and endurance, and flexibility. The ISO program consisted of primarily upper and lower extremity progressive resistance exercises. The INT program involved progressive resistance exercises, and core stability, power, and agility exercises. Thirty subjects were cluster randomized to either the ISO (n = 15) or INT (n = 15) training program. Each training group performed their respective programs 2 times per week for 8 weeks. The subjects were assessed before (pretest) and after (posttest) the intervention period using the following assessments: a jump-landing task graded using the Landing Error Scoring System (LESS), vertical jump height, T-test time, push-up and sit-up performance, and the sit-and-reach test. The INT group performed better on the LESS test (pretest: 3.90 ± 1.02, posttest: 3.03 ± 1.02; p = 0.02), faster on the T-test (pretest: 10.35 ± 1.20 seconds, posttest: 9.58 ± 1.02 seconds; p = 0.01), and completed more sit-ups (pretest: 40.20 ± 15.01, posttest: 46.73 ± 14.03; p = 0.045) and push-ups (pretest: 40.67 ± 13.85, posttest: 48.93 ± 15.17; p = 0.05) at posttest compared with pretest, and compared with the ISO group at posttest. Both groups performed more push-ups (p = 0.002), jumped higher (p < 0.001), and reached further (p = 0.008) at posttest compared with that at pretest. Performance enhancement programs should use an integrated approach to exercise selection to optimize performance and movement technique benefits.
UPPER BODY PUSH AND PULL STRENGTH RATIO IN RECREATIONALLY ACTIVE ADULTS
Hanney, William J.; Pabian, Patrick; Kolber, Morey J.
2013-01-01
Introduction: Agonist to antagonist strength data is commonly analyzed due to its association with injury and performance. The purpose of this study was to examine the agonist to antagonist ratio of upper body strength using two simple field tests (timed push up/timed modified pull up) in recreationally active adults and to establish the basis for reference standards. Methods: One hundred eighty (180) healthy recreationally active adults (111 females and 69 males, aged 18‐45 years) performed two tests of upper body strength in random order: 1. Push‐ups completed during 3 sets of 15 seconds with a 45 second rest period between each set and 2. Modified pull‐ups completed during 3 sets of 15 seconds with a 45 second rest period between each set. Results: The push‐up to modified pull‐up ratio for the males was 1.57:1, whereas females demonstrated a ratio of 2.72:1. The results suggest that for our group of healthy recreationally active subjects, the upper body “pushing” musculature is approximately 1.5–2.7 times stronger than the musculature involved for pulling. Conclusions: In this study, these recreationally active adults displayed greater strength during the timed push‐ups than the modified pull‐ups. The relationship of these imbalances to one's performance and or injury risk requires further investigation. The reference values, however, may serve the basis for future comparison and prospective investigations. The field tests in this study can be easily implemented by clinicians and an agonist/antagonist ratio can be determined and compared to our findings. Level of Evidence: 2b PMID:23593552
Pirauá, André Luiz Torres; Pitangui, Ana Carolina Rodarti; Silva, Juliana Pereira; Pereira dos Passos, Muana Hiandra; Alves de Oliveira, Valéria Mayaly; Batista, Laísla da Silva Paixão; Cappato de Araújo, Rodrigo
2014-10-01
The present study was performed to assess the electromyographic activity of the scapular muscles during push-ups on a stable and unstable surface, in subjects with scapular dyskinesis. Muscle activation (upper trapezius [UT]; lower trapezius [LT]; upper serratus anterior [SA_5th]; lower serratus anterior [SA_7th]) and ratios (UT/LT; UT/SA_5th; UT/ SA_7th) levels were determined by surface EMG in 30 asymptomatic men with scapular dyskinesis, during push-up performed on a stable and unstable surface. Multivariate analysis of variance with repeated measures was used for statistical analyses. The unstable surface caused a decrease in the EMG activity of the serratus anterior and an increase in EMG activity of the trapezius (p=0.001). UT/SA_5th and UT/ SA_7th ratios were higher during unstable push-ups (p=0.001). The results suggest that, in individuals with scapular dyskinesis, there is increased EMG activity of the trapezius and decreased EMG activity of the serratus anterior in response to an unstable surface. These results suggest that the performance of the push up exercise on an unstable surface may be more favorable to produce higher levels of trapezius activation and lower levels of serratus anterior activation. However, if the goal of the exercise program is the strengthening of the SA muscle, it is suggested to perform the push up on a stable surface. Copyright © 2014 Elsevier Ltd. All rights reserved.
Muscle activity levels in upper-body push exercises with different loads and stability conditions.
Calatayud, Joaquin; Borreani, Sebastien; Colado, Juan Carlos; Martin, Fernando; Rogers, Michael E
2014-11-01
Exercises that aim to stimulate muscular hypertrophy and increase neural drive to the muscle fibers should be used during rehabilitation. Thus, it is of interest to identify optimal exercises that efficiently achieve high muscle activation levels. The purpose of this study was to compare the muscle activation levels during push-up variations (ie, suspended push-ups with/without visual input on different suspension systems, and push-ups on the floor with/without additional elastic resistance) with the bench press exercise and the standing cable press exercise both performed at 50%, 70%, and 85% of the 1-repetition maximum. Young fit male university students (N = 29) performed 3 repetitions in all conditions under the same standardized procedures. Average amplitude of the electromyogram (EMG) root mean square for the rectus abdominis, external oblique, sternocostal head of the pectoralis major, anterior deltoid, long head of the triceps brachii, upper trapezius, anterior serratus, and posterior deltoid was recorded. The EMG signals were normalized to the maximum voluntary isometric contraction. The EMG data were analyzed with repeated-measures analysis of variance with a Bonferroni post hoc. Elastic-resisted push-ups induce similar EMG stimulus in the prime movers as the bench press at high loads while also providing a greater core challenge. Suspended push-ups are a highly effective way to stimulate abdominal muscles. Pectoralis major, anterior deltoid, and anterior serratus are highly elicited during more stable pushing conditions, whereas abdominal muscles, triceps brachii, posterior deltoid, and upper trapezius are affected in the opposite manner.
Nilsson, Johnny E; Rosdahl, Hans G
2014-03-01
The purpose was to develop and validate portable force-measurement devices for recording push and pull forces applied by each foot to the foot bar of a kayak and the horizontal force at the seat. A foot plate on a single-point force transducer mounted on the kayak foot bar underneath each foot allowed the push and pull forces to be recorded. Two metal frames interconnected with 4 linear ball bearings, and a force transducer allowed recording of horizontal seat force. The foot-bar-force device was calibrated by loading each foot plate with weights in the push-pull direction perpendicular to the foot plate surface, while the seat-force device was calibrated to horizontal forces with and without weights on the seat. A strong linearity (r2 = .99-1.0) was found between transducer output signal and load force in the push and pull directions for both foot-bar transducers perpendicular to the foot plate and the seat-force-measuring device. Reliability of both devices was tested by means of a test-retest design. The coefficient of variation (CV) for foot-bar push and pull forces ranged from 0.1% to 1.1%, and the CV for the seat forces varied from 0.6% to 2.2%. The current study opens up a field for new investigations of the forces generated in the kayak and ways to optimize kayak-paddling performance.
Development of a New Army Standardized Physical Readiness Test: January 2012 through December 2013
2015-06-30
that “Individual Service members must possess the cardio -respiratory endurance, muscular strength and muscular endurance, together with desirable...there appears to be less gender bias. While fitness tests have been associated with different aspect of fitness ( cardio respiratory endurance...9. 1 min Push-up 10. (upper body muscular endurance) 11. 2-mile Run 12. ( cardio -respiratory endurance) Army Combat Readiness Test (ACRT) was
Sefton, JoEllen M; Lohse, K R; McAdam, J S
2016-11-01
Musculoskeletal injuries (MSIs) are among the most important challenges facing our military. They influence career success and directly affect military readiness. Several methods of screening initial entry training (IET) soldiers are being tested in an effort to predict which soldiers will sustain an MSI and to develop injury-prevention programs. The Army 1-1-1 Fitness Assessment was examined to determine if it could be used as a screening and MSI prediction mechanism in male IET soldiers. To determine if a relationship existed among the Army 1-1-1 Fitness Assessment results and MSI, MSI type, and program of instruction (POI) in male IET soldiers. Retrospective cohort study. Fort Benning, Georgia. Male Army IET soldiers (N = 1788). The likelihood of sustaining acute and overuse MSI was modelled using separate logistic regression analyses. The POI, run time, push-ups and sit-ups (combined into a single score), and IET soldier age were tested as predictors in a series of linear models. With POI controlled, slower run time, fewer push-ups and sit-ups, and older age were positively correlated with acute MSI; only slower run time was correlated with overuse MSI. For both MSI types, cavalry POIs had a higher risk of acute and overuse MSIs than did basic combat training, armor, or infantry POIs. The 1-1-1 Fitness Assessment predicted both the likelihood of MSI occurrence and type of MSI (acute or overuse). One-mile (1.6-km) run time predicted both overuse and acute MSIs, whereas the combined push-up and sit-up score predicted only acute MSIs. The MSIs varied by type of training (infantry, basic, armor, cavalry), which allowed the development of prediction equations by POI. We determined 1-1-1 Fitness Assessment cutoff scores for each event, thereby allowing the evaluation to be used as an MSI screening mechanism for IET soldiers.
Sefton, JoEllen M.; Lohse, K. R.; McAdam, J. S.
2016-01-01
Context: Musculoskeletal injuries (MSIs) are among the most important challenges facing our military. They influence career success and directly affect military readiness. Several methods of screening initial entry training (IET) soldiers are being tested in an effort to predict which soldiers will sustain an MSI and to develop injury-prevention programs. The Army 1-1-1 Fitness Assessment was examined to determine if it could be used as a screening and MSI prediction mechanism in male IET soldiers. Objective: To determine if a relationship existed among the Army 1-1-1 Fitness Assessment results and MSI, MSI type, and program of instruction (POI) in male IET soldiers. Design: Retrospective cohort study. Setting: Fort Benning, Georgia. Patients or Other Participants: Male Army IET soldiers (N = 1788). Main Outcome Measure(s): The likelihood of sustaining acute and overuse MSI was modelled using separate logistic regression analyses. The POI, run time, push-ups and sit-ups (combined into a single score), and IET soldier age were tested as predictors in a series of linear models. Results: With POI controlled, slower run time, fewer push-ups and sit-ups, and older age were positively correlated with acute MSI; only slower run time was correlated with overuse MSI. For both MSI types, cavalry POIs had a higher risk of acute and overuse MSIs than did basic combat training, armor, or infantry POIs. Conclusions: The 1-1-1 Fitness Assessment predicted both the likelihood of MSI occurrence and type of MSI (acute or overuse). One-mile (1.6-km) run time predicted both overuse and acute MSIs, whereas the combined push-up and sit-up score predicted only acute MSIs. The MSIs varied by type of training (infantry, basic, armor, cavalry), which allowed the development of prediction equations by POI. We determined 1-1-1 Fitness Assessment cutoff scores for each event, thereby allowing the evaluation to be used as an MSI screening mechanism for IET soldiers. PMID:28068160
Clock Ticks on Senate ESEA Plan
ERIC Educational Resources Information Center
Klein, Alyson
2011-01-01
The author reports on a measure to renew the Elementary and Secondary Education Act (ESEA), which faces steep political hurdles. Leaders of the Senate education committee still aim to push a bipartisan revision of the much-criticized No Child Left Behind Act through Congress by year's end, in time to stave off the Obama administration's move to…
Top Surgery in Transgender Men: How Far Can You Push the Envelope?
Bluebond-Langner, Rachel; Berli, Jens U; Sabino, Jennifer; Chopra, Karan; Singh, Devinder; Fischer, Beverly
2017-04-01
The authors present their grading scale and the outcomes of the largest cohort of top surgery published to date. Application of this grading system can help determine which patients will benefit from a subcutaneous mastectomy with free nipple graft versus a circumareolar technique, with the primary endpoint being need for aesthetic revisions. The authors reviewed their database of transgender males who underwent bilateral mastectomy between 2006 and 2015. Data collected included age, body mass index, American Society of Anesthesiologists class, smoking, diabetes, testosterone use, months of social transition, technique used, postoperative complications, and need for revision. Two techniques were used, circumareolar incision and free nipple graft technique. Between 2006 and 2015, 1686 consecutive mastectomies were performed on 843 patients. Of those, 548 patients were excluded because of inadequate follow-up. Of the 295 included, 109 were treated using a circumareolar incision and 186 were treated using a free nipple graft technique. There was no statistically significant difference in complications between the two groups; however, there was a statistically significant difference in the rate of aesthetic revisions in the grade 2B circumareolar incision group (34 percent versus 8.8 percent). The authors' outcomes are comparable to the literature, and demonstrate that these procedures can safely be performed in an outpatient setting. The authors' grading scale classifies patients and helps the surgeon select a surgical technique. The authors show a statistical difference in rates of aesthetic revisions in Fischer grade 2B patients when a circumareolar incision is selected over a free nipple graft technique. Therapeutic, III.
[Progress in assays for and new developments in autoimmune pathophysioirmen's introductory remarks].
Miyazawa, Yukihisa; Shimadu, Chisato; Ohi, Kayoko
2005-11-01
We examined the influence of a revision of health insurance in 2004 in Teikyo University Hospital in comparison with 2003. Out to the returns of most hematological tests, especially HbA1c and TK, being included in the treatment charges of outpatients, gross laboratory test sales decreased more than expected. Increased income from judgment charges and management charges could not make up for the deficit in test sales. Therefore, total laboratory test revenues decreased substantially. In 2006, the new revision of health insurance will worsen the revenues further. Hospital laboratory test departments should take appropriate and aggressive management steps in response to these revisions in health insurance.
ERIC Educational Resources Information Center
Hill, Grant; Downing, Aaron
2015-01-01
The purpose of this study was to determine the effects of frequent peer-monitored Fitnessgram testing, with student goal setting, on the PACER and push-up performance of middle school students. Subjects were 176 females and 189 males in 10 physical education classes at a middle school with an 83.7% Hispanic student population. Students were…
White, G W; Mathews, R M; Fawcett, S B
1989-01-01
People who use wheelchairs are at risk for developing pressure sores. Regular pressure relief, in the form of a wheelchair push-up, is one way to reduce the likelihood of pressure sores. We examined the effects of antecedent (i.e., instructions, audible prompts) and consequent (i.e., alarm avoidance) events on wheelchair push-ups, using a multiple baseline analysis with 2 participants with spina bifida. Results suggest that the combined procedure was more effective than either antecedent or consequent events alone, and there is some evidence suggesting maintenance of effects over time. PMID:2793635
Efficacy of combining flexible and rigid ureteroscopy for transurethral lithotripsy.
Shigemura, Katsumi; Yasufuku, Tomihiko; Yamashita, Masuo; Arakawa, Soichi; Fujisawa, Masato
2010-08-23
Transurethral lithotripsy (TUL) is a common procedure in urology. However, controversy persists about how to deal with stones pushed up into kidney from the ureter during the procedure of TUL. This study investigated the efficacy of combining flexible ureteroscopy and rigid ureteroscopy for pushed-up stones into kidney during TUL. Fotry-one patients underwent TUL by a single surgeon from July 2007 to May 2009. Eight cases resulted in pushed-up stones during operation or involved existing kidney stones. We used a Zero-tip or Litho Catch Basket catheter and a flexible ureteroscope to carry these stones in kidney down into the ureter where the rigid ureteroscope could then reach and handle the stone for lithotripsy or being taken away. A Lithoclast system was used for lithotripsy. Five cases involved stones pushed up during surgery and 3 cases involved stones already in the kidney in detail. We pulled the stones down into the ureter in all cases and successfully completed lithotripsy or removed the stone, thus avoiding the performance of additional extracorporeal shock wave lithotripsy (ESWL). In conclusions, combined use of flexible ureteroscopy and rigid ureteroscopy for upper urinary tract stones pushed up into the kidney during TUL or renal stones could be useful for avoiding additional ESWL.
The Physical Characteristics by Sex and Age for Custody Assistants from a Law Enforcement Agency.
Lockie, Robert G; Orr, Robin M; Stierli, Michael; Cesario, Karly A; Moreno, Matthew R; Bloodgood, Ashley M; Dulla, Joseph M; Dawes, J Jay
2018-01-17
Custody assistants (CAs) are a position within a law enforcement agency who are responsible for assisting officers with maintaining security in correctional facilities. Unlike other positions, CAs may not be required to complete physical testing prior to being hired. This lack of testing could influence the characteristics of CAs who attend academy training. Therefore, retrospective analysis of performance test data for 108 officers (69 males, 39 females) was conducted. The tests included: grip strength for both hands; number of push-ups and sit-ups in 60 seconds; 201 m (220 yard) and 2.4 km runs; and maximal aerobic capacity (V˙O2max) estimated from the 2.4 km run. Data were stratified by sex and age (≤24 years, 25-29 years, 30-34 years, ≥35 years). Independent samples t-tests (p < 0.05) calculated differences between males and females. To compare age groups, a one-way ANOVA with Bonferroni post hoc was utilized (p < 0.05). Males scored significantly higher than females in hand grip, push-ups, and sit-ups, were faster over the 201 m and 2.4 km runs, and had a higher V˙O2max (p ≤ 0.001-0.024). There were no significant differences in performance tests across the age groups for either males or females. To better tolerate the rigors of physical training, female CAs should attempt to improve their fitness prior to academy as they often need to complete the same tasks as the males. Age did not appear to influence the physical characteristics of CAs, although all CAs should attempt to develop the fitness qualities needed for their occupation.
... and you need to throw up. The muscles push the food back out of the stomach so it comes up ... body the power it needs to lift and push things. Muscles in your neck and the top part of your back aren't as large, but they are capable ...
Hydraulic tests with direct-push equipment
Butler, J.J.; Healey, J.M.; McCall, G.W.; Garnett, E.J.; Loheide, Steven P.
2002-01-01
The potential of direct-push technology for hydraulic characterization of saturated flow systems was investigated at a field site with a considerable degree of subsurface control. Direct-push installations were emplaced by attaching short lengths of screen (shielded and unshielded) to the bottom end of a tool string that was then advanced into the unconsolidated sediments. A series of constant-rate pumping tests were performed in a coarse sand and gravel aquifer using direct-push tool strings as observation wells. Very good agreement (within 4%) was found between hydraulic conductivity (K) estimates from direct-push installations and those from conventional wells. A program of slug tests was performed in direct-push installations using small-diameter adaptations of solid-slug and pneumatic methods. In a sandy silt interval of moderate hydraulic conductivity, K values from tests in a shielded screen tool were in excellent agreement (within 2%) with those from tests in a nearby well. In the coarse sand and gravel aquifer, K values were within 12% of those from multilevel slug tests at a nearby well. However, in the more permeable portions of the aquifer (K > 70 m/day), the smaller-diameter direct-push rods (0.016 m inner diameter [I.D.]) attenuated test responses, leading to an underprediction of K. In those conditions, use of larger-diameter rods (e.g., 0.038 m I.D.) is necessary to obtain K values representative of the formation. This investigation demonstrates that much valuable information can be obtained from hydraulic tests in direct-push installations. As with any type of hydraulic test, K estimates are critically dependent on use of appropriate emplacement and development procedures. In particular, driving an unshielded screen through a heterogeneous sequence will often lead to a buildup of low-K material that can be difficult to remove with standard development procedures.
Scapular kinematics and shoulder elevation in a traditional push-up.
Suprak, David N; Bohannon, Jennifer; Morales, Gabriel; Stroschein, Joseph; San Juan, Jun G
2013-01-01
Proper scapulothoracic motion is critical for the health and function of the shoulder and represents a principal focus in the rehabilitation setting. Variants of the traditional push-up are used frequently to help restore proper scapular kinematics. To date, substantial research has focused on muscle activation levels of rotator cuff and scapular-stabilizing musculature, whereas a dearth of literature exists regarding scapular kinematics during push-up variants. To examine the effect of shoulder position on scapular kinematics across the range of motion (ROM) of a traditional push-up. Cross-sectional study. University laboratory. Sixteen healthy participants without a history of upper extremity or spine injury requiring rehabilitation or surgery. Participants performed a traditional push-up while kinematic measurements were acquired from multiple upper extremity segments. The 3 shoulder position conditions were (1) self-selected position, (2) shoulder adducted upon ascent (at side), and (3) shoulder elevated to approximately 90°. Scapular posterior tilt, upward rotation, and external rotation were examined across elbow-extension ROM and compared across conditions. Posterior tilt was greater in the self-selected and at-side conditions than in the elevated condition and increased linearly with elbow extension. External rotation was greater in the self-selected and at-side conditions compared with that in the elevated condition. In the at-side condition, upward rotation began lower than in the other conditions at the start of the concentric phase but increased above the others soon after the elbow started to extend. Performing a traditional push-up with the shoulders elevated may place the scapula in a position of impingement. Clinicians should be cognizant of shoulder elevation when prescribing and monitoring exercise progression. The results of this study will provide further direction for clinicians in prescribing rehabilitation exercises for the upper extremity, especially closed chain exercises for shoulder conditions.
Louis, M-L; D'ingrado, P; Ehkirch, F P; Bertiaux, S; Colombet, P; Sonnery-Cottet, B; Schlatterer, B; Pailhé, R; Panisset, J C; Steltzlen, C; Lustig, S; Lutz, C; Dalmay, F; Imbert, P; Saragaglia, D
2017-12-01
A careful analysis of the reasons for ACL reconstruction failure is essential to selection of the optimal surgical revision technique designed to ensure good rotational stability and to minimise the risk of re-rupture. To evaluate anterolateral ligament (ALL) stabilisation during revision ACL reconstruction. ALL stabilisation during revision ACL reconstruction provides good rotational stability without increasing the risk of complications. This multicentre study included 349 patients, 151 retrospectively and 198 prospectively. There were 283 males and 66 females. Inclusion criteria were an indication for revision ACL reconstruction surgery with combined intra-articular reconstruction and ALL stabilisation after failed autograft ACL reconstruction, and intact PCL. Exclusion criteria were primary ACL reconstruction and concomitant peripheral medial and/or lateral lesions. Each patient underwent a clinical and radiographic evaluation before and after revision surgery. Before revision surgery, the mean IKDC score was 56.5±15.5 and 96% of patients were IKDC C or D. Rates were 5.0% for early and 10.5% for late postoperative complications. Lachmann's test had a hard stop at last follow-up in 97% of patients. The pivot-shift test was positive in 1% of patients. The mean subjective IKDC score was 84.5±13.0 and 86.5% of patients were IKDC A or B. The proportions of patients with radiographic knee osteoarthritis at last follow-up was unchanged for the lateral tibio-femoral and patello-femoral compartments but increased by 9.7% to 21.2% for the medial tibio-femoral compartment. The re-rupture rate was 1.2% and the further surgical revision rate was 5.4%. Anterior laxity at last follow-up was consistent with previous studies of revision ACL reconstruction. However, rotational stability and the re-rupture risk were improved. ALL stabilisation is among the techniques that deserve consideration as part of the therapeutic options for revision ACL reconstruction. IV, retrospective and prospective cohort study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
One-stage Revision ACL reconstruction with hamstring autograft results in satisfactory outcome
Kejriwal, Ritwik; Buelow, Jens
2017-01-01
Objectives: Revision anterior cruciate ligament (ACL) reconstruction is associated with poorer outcomes and higher rerupture rates when compared to primary ACL reconstruction. There is also a significant heterogeneity in surgical technique, number of stages, and graft options. We report a large single surgeon case series with hamstring autograft as a graft option. Methods: Observational series of revision ACL reconstructions performed by the senior author between 2005 and 2015 was carried out. Chart reviews and clinic follow-ups were performed with the following recorded – re-rupture rate, radiographic grading of osteoarthritis, KT-1000 arthrometer test, IKDC outcome scores and knee range of motion. All patients underwent single bundle four-strand hamstring autograft performed in one stage with use of new tunnels in majority of the cases. Results: 66 patients underwent hamstring autograft one-stage revision ACL reconstruction by Dr Jens Buelow. Chart review was carried out on all patients, and 26 (39%) were followed up in clinic and/or by phone with a mean follow up of 4.7 years. Outcomes included re-rupture rate of 4.5%, reoperation rate of 12%, mean visual analogue scale score of 7.6, mean side-to-side difference of 2.6 mm for KT-1000 arthrometer test, and mean IKDC score of 79. Of the 17 patients with radiographs, 40% had moderate osteoarthritis (grade 2 or 3) at follow-up. Conclusion: Revision ACL reconstruction can result in a satisfactory outcome when performed with a hamstring autograft in one stage.
2015-10-26
platforms and are quickly using up available spectrum. The national need in the commercial sector with emerging technologies such as 5G is pushing for...recovered and post processed later. The Front End Server also sends selected data stream across a high speed network link to the centralized
RTT Goals Challenge Recipients
ERIC Educational Resources Information Center
McNeil, Michele
2011-01-01
Ambitious student-achievement targets turn up the heat, as winners of the $4 billion federal grant effort push to deliver. Winners of the $4 billion Race to the Top jackpot committed to grand goals in using the federal grants to raise student achievement, as measured by higher test scores, narrowed achievement gaps, and increased graduation and…
Mmbando, Arnold S.; Ngowo, Halfan S.; Kilalangongono, Masoud; Abbas, Said; Matowo, Nancy S.; Moore, Sarah J.; Okumu, Fredros O.
2017-01-01
Background: Despite high coverage of indoor interventions like insecticide-treated nets, mosquito-borne infections persist, partly because of outdoor-biting, early-biting and insecticide-resistant vectors. Push-pull systems, where mosquitoes are repelled from humans and attracted to nearby lethal targets, may constitute effective complementary interventions. Methods: A partially randomized cross-over design was used to test efficacy of push-pull in four experimental huts and four local houses, in an area with high pyrethroid resistance in Tanzania. The push-pull system consisted of 1.1% or 2.2% w/v transfluthrin repellent dispensers and an outdoor lure-and-kill device (odour-baited mosquito landing box). Matching controls were set up without push-pull. Adult male volunteers collected mosquitoes attempting to bite them outdoors, but collections were also done indoors using exit traps in experimental huts and by volunteers in the local houses. The collections were done hourly (1830hrs-0730hrs) and mosquito catches compared between push-pull and controls. An. gambiae s.l. and An. funestus s.l. were assessed by PCR to identify sibling species, and ELISA to detect Plasmodium falciparum and blood meal sources. Results: Push-pull in experimental huts reduced outdoor-biting for An. arabiensis and Mansonia species by 30% and 41.5% respectively. However, the reductions were marginal and insignificant for An. funestus (12.2%; p>0.05) and Culex (5%; p>0.05). Highest protection against all species occurred before 2200hrs. There was no significant difference in number of mosquitoes inside exit traps in huts with or without push-pull. In local households, push-pull significantly reduced indoor and outdoor-biting of An. arabiensis by 48% and 25% respectively, but had no effect on other species. Conclusion: This push-pull system offered modest protection against outdoor-biting An. arabiensis, without increasing indoor mosquito densities. Additional experimentation is required to assess how transfluthrin-based products affect mosquito blood-feeding and mortality in push-pull contexts. This approach, if optimised, could potentially complement existing malaria interventions even in areas with high pyrethroid resistance. PMID:29568808
Motor abilities and anthropometrics in youth cross-country skiing.
Stöggl, R; Müller, E; Stöggl, T
2015-02-01
The purposes were to validate whether general motor abilities and anthropometrics are determinants of youth cross-country (XC) skiing performance; evaluate gender-specific differences; and to establish noninvasive diagnostics. Fifty-one youth XC skiers (34 boys; 13.8 ± 0.6 years and 17 girls; 13.4 ± 0.9 years) performed motor skill and laboratory tests, and anthropometric data were collected and correlated with XC skiing performance. Anthropometrics and maturity status were related to boys but not to girls XC skiing performance. Push-ups and 20-m sprint were correlated to XC skiing performance in both boys and girls. XC skiing performance of boys was predominantly influenced by upper body and trunk strength capacities (medicine ball throw, push-ups, and pull-ups) and jumping power (standing long and triple jump), whereas XC skiing of girls was mainly influenced by aerobic capacities (3000-m run). Laboratory measures did not reveal greater correlations to XC skiing performance compared with simple test concepts of speed, strength, and endurance. Maturity was a major confounding variable in boys but not girls. Use of noninvasive simple test concepts for determination of upper body strength, speed, and endurance represent practicable support for ski clubs, schools, or skiing federations in the guidance and evaluation of young talent, being aware of the effect of maturity especially in boys. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Feldacker, Caryl; Chicumbe, Sergio; Dgedge, Martinho; Cesar, Freide; Augusto, Gerito; Robertson, Molly; Mbofana, Francisco; O'Malley, Gabrielle
2015-04-16
Mozambique suffers from critical shortages of healthcare workers including non-physician clinicians, Tecnicos de Medicina Geral (TMGs), who are often senior clinicians in rural health centres. The Mozambique Ministry of Health and the International Training and Education Center for Health, University of Washington, Seattle, revised the national curriculum to improve TMG clinical knowledge and skills. To evaluate the effort, data was collected at graduation and 10 months later from pre-revision (initial) and revised curriculum TMGs to determine the following: (1) Did cohorts trained in the revised curriculum score higher on measurements of clinical knowledge, physical exam procedures, and solving clinical case scenarios than those trained in the initial curriculum; (2) Did TMGs in both curricula retain their knowledge over time (from baseline to follow-up); and (3) Did skills and knowledge retention differ over time by curricula? Post-graduation and over time results are presented. t-tests examine differences in scores between curriculum groups. Univariate and multivariate linear regression models assess curriculum-related, demographic, and workplace factors associated with scores on each of three evaluation methods at the p < 0.05 level. Paired t-tests examine within-group changes over time. ANOVA models explore differences between Health Training Institutes (HTIs). Generalized estimating equations determine whether change in scores over time differed by curricula. Mean scores of initial curriculum TMGs at follow-up were 52.7%, 62.6%, and 40.0% on the clinical cases, knowledge test, and physical exam, respectively. Averages were significantly higher among the revised group for clinical cases (60.2%; p < 0.001) and physical exam (47.6%; p < 0.001). HTI was influential on clinical case and physical exam scores. Between graduation and follow-up, clinical case and physical exam scores decreased significantly for initial curriculum students; clinical case scores increased significantly among revised curriculum TMGs. Although curriculum revision had limited effect, marginal improvements in the revised group show promise that these TMGs may have increased ability to synthesize clinical information. Weaknesses in curriculum and practicum implementation likely compromised the effect of curriculum revision. An improvement strategy that includes strengthened TMG training, greater attention to pre-service clinical practice, and post-graduation mentoring may be more advantageous than curriculum revision, alone, to improve care provided by TMGs.
2014 Teacher Prep Review: A Review of the Nation's Teacher Preparation Programs. Revised
ERIC Educational Resources Information Center
Greenberg, Julie; Walsh, Kate; McKee, Arthur
2015-01-01
Ever so slowly, the United States is taking a harder look at how its teacher preparation schools are improving the quality of the teachers they produce. The signs are everywhere--from proposed federal action to state legislatures and school boards passing new oversight laws and regulations, to a newly marshaled push for stronger accreditation by…
Prototype pushing robot for emplacing vitrified waste canisters into horizontal disposal drifts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Londe, L.; Seidler, W.K.; Bosgiraud, J.M.
2007-07-01
Within the French Underground Disposal concept, as described in ANDRA's (Agence Nationale pour la Gestion des Dechets Radioactifs) Dossier 2005, the Pushing Robot is an application envisaged for the emplacement (and the potential retrieval) of 'Vitrified waste packages', also called 'C type packages'. ANDRA has developed a Prototype Pushing Robot within the framework of the ESDRED Project (Engineering Studies and Demonstration of Repository Design) which is co-funded by the European Commission as part of the sixth EURATOM Research and Training Framework Programme (FP6) on nuclear energy (2002 - 2006). The Rationale of the Pushing Robot technology comes from various considerations,more » including the need for (1) a simple and robust system, capable of moving (and potentially retrieving) on up to 40 metres (m), a 2 tonne C type package (mounted on ceramic sliding runners) inside the carbon steel sleeve constituting the liner (and rock support) of a horizontal disposal cell, (2) small annular clearances between the package and the liner, (3) compactness of the device to be transferred from surface to underground, jointly with the package, inside a shielding cask, and (4) remote controlled operations for the sake of radioprotection. The initial design, based on gripping supports, has been replaced by a 'technical variant' based on inflatable toric jacks. It was then possible, using a test bench, to check that the Pushing Robot worked properly. Steps as high as 7 mm were successfully cleared by a dummy package pushed by the Prototype.. Based on the lessons learned by ANDRA's regarding the Prototype Pushing Robot, a new Scope of Work is being written for the Contract concerning an Industrial Scale Demonstrator. The Industrial Scale Demonstration should be completed by the end of the second Quarter of 2008. (authors)« less
Common-pull, multiple-push, vacuum-activated telescope mirror cell.
Ruiz, Elfego; Sohn, Erika; Salas, Luis; Luna, Esteban; Araiza-Durán, José A
2014-11-20
A new concept for push-pull active optics is presented, where the push-force is provided by means of individual airbag type actuators and a common force in the form of a vacuum is applied to the entire back of the mirror. The vacuum provides the pull-component of the system, in addition to gravity. Vacuum is controlled as a function of the zenithal angle, providing correction for the axial component of the mirror's weight. In this way, the push actuators are only responsible for correcting mirror deformations, as well as for supporting the axial mirror weight at the zenith, allowing for a uniform, full dynamic-range behavior of the system along the telescope's pointing range. This can result in the ability to perform corrections of up to a few microns for low-order aberrations. This mirror support concept was simulated using a finite element model and was tested experimentally at the 2.12 m San Pedro Mártir telescope. Advantages such as stress-free attachments, lighter weight, large actuator area, lower system complexity, and lower required mirror-cell stiffness could make this a method to consider for future large telescopes.
Boeing's CST-100 Launch Abort Engine Test
2016-10-20
A launch abort engine built by Aerojet Rocketdyne is hot-fired during tests in the Mojave Desert in California. The engine produces up to 40,000 pounds of thrust and burns hypergolic propellants. The engines have been designed and built for use on Boeing’s CST-100 Starliner spacecraft in sets of four. In an emergency at the pad or during ascent, the engines would ignite to push the Starliner and its crew out of danger.
Boeing's CST-100 Launch Abort Engine Test
2016-10-17
A launch abort engine built by Aerojet Rocketdyne is hot-fired during tests in the Mojave Desert in California. The engine produces up to 40,000 pounds of thrust and burns hypergolic propellants. The engines have been designed and built for use on Boeing’s CST-100 Starliner spacecraft in sets of four. In an emergency at the pad or during ascent, the engines would ignite to push the Starliner and its crew out of danger.
ERIC Educational Resources Information Center
Attali, Yigal; Powers, Don; Hawthorn, John
2008-01-01
Registered examinees for the GRE® General Test answered open-ended sentence-completion items. For half of the items, participants received immediate feedback on the correctness of their answers and up to two opportunities to revise their answers. A significant feedback-and-revision effect was found. Participants were able to correct many of their…
Battery life test using reconditioning
NASA Technical Reports Server (NTRS)
Sparks, R. H.
1977-01-01
A discussion is presented on nickel cadmium battery life tests using reconditioning and some comparative tests not using reconditioning. The discussion is aimed at the program application part of the testing. The goals of the program were to get an increased utilization out of the battery system in geosynchronous orbit. An attempt was made to push the depth of discharge operation up around 80 to 85 percent and the intent with the reconditioning program was to extend this type of utilization out towards a 10-year life and attune the voltage regulation.
Comparison of Body Composition Metrics for United States Air Force Airmen.
Griffith, J R; White, Edward D; Fass, R David; Lucas, Brandon M
2018-03-01
The United States Air Force currently uses AFI 36-2905 for cardiovascular fitness standards and evaluation. Regarding its fitness test, the Air Force considers waist circumference (WC) twice as important as push-ups or sit-ups. Because of this weighting, one assumes that the Air Force considers WC relatively correlated with overall fitness or at least cardiovascular fitness. To our knowledge, the Air Force has not considered on a large scale how body mass index (BMI), height-to-weight ratio (H-W), or waist-to-height ratio (WHtR) compares with WC with respect to its fitness test. Using a 5.38 million record database from the Air Force Fitness Management System, we evaluated how WC, BMI, WHtR, and H-W correlate with fitness as assessed by the 1.5-mile run in addition to total fitness, which incorporates the 1.5-mile run time, number of push-ups and sit-ups. As this previously collected data were anonymous to us, this study fell under the definition of exempt status and approved by the institutional review board overseeing Joint Base San Antonio. For each waist metric, we performed a simple ordinary least squares regression to ascertain the correlation between that particular metric and either run time or total fitness; when incorporating more than one explanatory variable or covariate (to control for age and/or sex), we performed multiple ordinary least squares regressions. Due to the large database size and to mitigate against a type I error, we used an alpha of 0.001 for all statistical hypothesis tests. Approximately 18% of the 5.38 million records belonged to women. With respect to sex differences, males appeared noticeably faster and performed more push-ups on average than females. The number of sit-ups completed was more comparable, with males having a slight advantage. Males also appeared to have larger WC, BMI, H-W, and WHtR measurements. We compared the ordinary least squares results between WC, H-W, WHtR, and BMI and ranked them by R2. Models varied in R2 from 1% to 46% depending on the covariates in the model, with sex having a greater effect than age. Whether individually or adjusting for age and sex, WHtR performed better than the other body composition variables with an average rank score of 1.1 and a median improvement of approximately 4% to the current Air Force metric of WC. From our findings, we present a 20-point WHtR scoring system for the Air Force to use in lieu of its traditional usage of WC. We used this assessment chart to score all Airmen in our database and compared the results to their current scores on the abdominal circumference portion of the test with respect to predicting run time, after accounting for sex, age, and number of push-ups and sit-ups. The R2 value improved from 40.3 to 43.6, a relative improvement of approximately 8%, a fairly significant effect given the database consisted of over 5 million records. Future studies should investigate the longitudinal effect of varying waist metrics over time on run time or total fitness performance. Published by Oxford University Press on behalf of the Association of Military Surgeons of the United States 2018. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Evaluating Upper-Body Strength and Power From a Single Test: The Ballistic Push-up.
Wang, Ran; Hoffman, Jay R; Sadres, Eliahu; Bartolomei, Sandro; Muddle, Tyler W D; Fukuda, David H; Stout, Jeffrey R
2017-05-01
Wang, R, Hoffman, JR, Sadres, E, Bartolomei, S, Muddle, TWD, Fukuda, DH, and Stout, JR. Evaluating upper-body strength and power from a single test: the ballistic push-up. J Strength Cond Res 31(5): 1338-1345, 2017-The purpose of this study was to examine the reliability of the ballistic push-up (BPU) exercise and to develop a prediction model for both maximal strength (1 repetition maximum [1RM]) in the bench press exercise and upper-body power. Sixty recreationally active men completed a 1RM bench press and 2 BPU assessments in 3 separate testing sessions. Peak and mean force, peak and mean rate of force development, net impulse, peak velocity, flight time, and peak and mean power were determined. Intraclass correlation coefficients were used to examine the reliability of the BPU. Stepwise linear regression was used to develop 1RM bench press and power prediction equations. Intraclass correlation coefficient's ranged from 0.849 to 0.971 for the BPU measurements. Multiple regression analysis provided the following 1RM bench press prediction equation: 1RM = 0.31 × Mean Force - 1.64 × Body Mass + 0.70 (R = 0.837, standard error of the estimate [SEE] = 11 kg); time-based power prediction equation: Peak Power = 11.0 × Body Mass + 2012.3 × Flight Time - 338.0 (R = 0.658, SEE = 150 W), Mean Power = 6.7 × Body Mass + 1004.4 × Flight Time - 224.6 (R = 0.664, SEE = 82 W); and velocity-based power prediction equation: Peak Power = 8.1 × Body Mass + 818.6 × Peak Velocity - 762.0 (R = 0.797, SEE = 115 W); Mean Power = 5.2 × Body Mass + 435.9 × Peak Velocity - 467.7 (R = 0.838, SEE = 57 W). The BPU is a reliable test for both upper-body strength and power. Results indicate that the mean force generated from the BPU can be used to predict 1RM bench press, whereas peak velocity and flight time measured during the BPU can be used to predict upper-body power. These findings support the potential use of the BPU as a valid method to evaluate upper-body strength and power.
Weston, Eric B; Aurand, Alexander; Dufour, Jonathan S; Knapik, Gregory G; Marras, William S
2018-06-01
Though biomechanically determined guidelines exist for lifting, existing recommendations for pushing and pulling were developed using a psychophysical approach. The current study aimed to establish objective hand force limits based on the results of a biomechanical assessment of the forces on the lumbar spine during occupational pushing and pulling activities. Sixty-two subjects performed pushing and pulling tasks in a laboratory setting. An electromyography-assisted biomechanical model estimated spinal loads, while hand force and turning torque were measured via hand transducers. Mixed modelling techniques correlated spinal load with hand force or torque throughout a wide range of exposures in order to develop biomechanically determined hand force and torque limits. Exertion type, exertion direction, handle height and their interactions significantly influenced dependent measures of spinal load, hand force and turning torque. The biomechanically determined guidelines presented herein are up to 30% lower than comparable psychophysically derived limits and particularly more protective for straight pushing. Practitioner Summary: This study utilises a biomechanical model to develop objective biomechanically determined push/pull risk limits assessed via hand forces and turning torque. These limits can be up to 30% lower than existing psychophysically determined pushing and pulling recommendations. Practitioners should consider implementing these guidelines in both risk assessment and workplace design moving forward.
Analytical solutions for efficient interpretation of single-well push-pull tracer tests
NASA Astrophysics Data System (ADS)
Huang, Junqi; Christ, John A.; Goltz, Mark N.
2010-08-01
Single-well push-pull tracer tests have been used to characterize the extent, fate, and transport of subsurface contamination. Analytical solutions provide one alternative for interpreting test results. In this work, an exact analytical solution to two-dimensional equations describing the governing processes acting on a dissolved compound during a modified push-pull test (advection, longitudinal and transverse dispersion, first-order decay, and rate-limited sorption/partitioning in steady, divergent, and convergent flow fields) is developed. The coupling of this solution with inverse modeling to estimate aquifer parameters provides an efficient methodology for subsurface characterization. Synthetic data for single-well push-pull tests are employed to demonstrate the utility of the solution for determining (1) estimates of aquifer longitudinal and transverse dispersivities, (2) sorption distribution coefficients and rate constants, and (3) non-aqueous phase liquid (NAPL) saturations. Employment of the solution to estimate NAPL saturations based on partitioning and non-partitioning tracers is designed to overcome limitations of previous efforts by including rate-limited mass transfer. This solution provides a new tool for use by practitioners when interpreting single-well push-pull test results.
Mehrotra, Seema; Sudhir, Paulomi; Rao, Girish; Thirthalli, Jagadisha; Srikanth, T K
2018-03-22
There is a dearth of published research on uptake and utility of mental health apps in India, despite a rising global trend in the application of technology in the field of mental health. We describe the development and pilot testing of a self-help intervention for depression, PUSH-D (Practice and Use Self-Help for Depression) for urban Indians. This guided self-help app, with essential and optional zone sections, was developed to provide a comprehensive coverage of therapeutic strategies drawn from cognitive behavior therapy, interpersonal therapy, supportive psychotherapy, and positive psychology. Pilot testing was carried out using a single group pre-, post- and follow-up design in 78 eligible participants. Participants were typically young adults with major depression or dysthymia and significant impairment in functioning. Almost two-thirds of the participants had never sought professional mental health help. Significant reductions in depression and improvement in the functioning and well-being were notedon standardized measures in participants completing all 10 essential zone sections. These gains were maintained at follow-up. The results were similar for partial completers, who completed fiveout of the 10 essential sections. PUSH-D is one of the first indigenously developed self-help apps for depression and it shows promise in reducing the treatment gap for depression in India.
Pushed or Pulled? Exploring the Factors Underpinning Graduate Start-Ups and Non-Start-Ups
ERIC Educational Resources Information Center
Nabi, G.; Walmsley, A.; Holden, R.
2015-01-01
The study explores the nature and mixture of push--pull factors in the journey from higher education into graduate entrepreneurship. Using longitudinal data from 15 graduates of a British university, it compares graduates who started their own business with graduates that did not. Importantly, both groups had initially indicated a strong desire to…
Gillesby, Erica; Burns, Suzan; Dempsey, Amy; Kirby, Shirley; Mogensen, Kami; Naylor, Kelly; Petrella, Joann; Vanicelli, Rebecca; Whelan, Breon
2010-01-01
To determine if the use of delayed pushing after the onset of the second stage of labor decreases the time of active pushing and decreases maternal fatigue. Randomized clinical trial. Labor and delivery unit of a not-for-profit community hospital. Convenience sample of nulliparous laboring women with epidural anesthesia. Immediate or delayed pushing (2 hours) during the second stage of labor at the time of complete cervical dilatation. The length of pushing, total length of the second stage, and maternal fatigue. A total of 77 women were studied (immediate pushing group=39; delayed pushing=38). The immediate pushing group averaged 94 (± 57) minutes in active pushing, while the delayed pushing group averaged 68 (± 46) minutes, a statistically significant difference (p=.04). No significant differences were found in fatigue scores between the immediate and delayed pushing groups (p>.05). We found that by delaying the onset of active pushing for 2 hours after the beginning of the second stage of labor, the time that nulliparous women with epidural anesthesia spent in active pushing was significantly decreased by 27%. Although the delayed pushing group rested for up to 2 hours, the total time in the second stage of labor averaged only 59 minutes longer than the immediate pushing group. © 2010 AWHONN, the Association of Women's Health, Obstetric and Neonatal Nurses.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... rate of particulate matter (lb/ton of coke) from a control device applied to pushing emissions where a... combined weight in tons of coke pushed during the duration of each test run according to the procedures in...
Code of Federal Regulations, 2010 CFR
2010-07-01
...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... rate of particulate matter (lb/ton of coke) from a control device applied to pushing emissions where a... combined weight in tons of coke pushed during the duration of each test run according to the procedures in...
Code of Federal Regulations, 2012 CFR
2012-07-01
...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... rate of particulate matter (lb/ton of coke) from a control device applied to pushing emissions where a... combined weight in tons of coke pushed during the duration of each test run according to the procedures in...
Code of Federal Regulations, 2014 CFR
2014-07-01
...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... rate of particulate matter (lb/ton of coke) from a control device applied to pushing emissions where a... combined weight in tons of coke pushed during the duration of each test run according to the procedures in...
Code of Federal Regulations, 2013 CFR
2013-07-01
...) National Emission Standards for Hazardous Air Pollutants for Coke Ovens: Pushing, Quenching, and Battery... rate of particulate matter (lb/ton of coke) from a control device applied to pushing emissions where a... combined weight in tons of coke pushed during the duration of each test run according to the procedures in...
Fox, Jeff A; Pierce, Mark; Bojchuk, John; Hayden, Jennifer; Bush-Joseph, Charles A; Bach, Bernard R
2004-10-01
To evaluate the effectiveness of a revision anterior cruciate ligament reconstruction with nonirradiated patellar tendon allograft used to salvage a failed index patellar tendon autograft procedure. Retrospective case series with minimum 2-year follow-up. Between 1993 and 1999, 39 patients underwent a revision reconstruction. Clinical, radiographic, arthrometric, and functional evaluations were performed. The Tegner, Lysholm, Noyes, Knee Injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee (IKDC), and SF-12 rating scales were used. Statistical analysis was conducted with our Biostatistics Department. Thirty-two of 38 patients (84%) were personally evaluated. The mean patient age was 28 years (range, 16 to 57 years); the mean follow-up was 4.8 years (range, 2.1 to 12.1 years). After revision, there were significant improvements in the Lachman and pivot-shift test results: 87% had a grade 0/1+ Lachman and a 0/1+ pivot-shift. However, 25% had a grade 1+ pivot-shift. Postoperatively, KT-1000 testing revealed that 84% had a maximum manual side-to-side difference of < or =3 mm and 6% had >5 mm. Functional testing revealed a mean 4% difference in side-to-side comparisons for a single-leg hop for distance and time, as well as vertical jump. The mean results of Noyes sports function (72), Lysholm (75), Tegner (6.3), KOOS sports activity scale (67), SF-12 physical component (48), SF-12 mental component (55), and IKDC (71) were obtained. The Noyes sports activity score showed a significant improvement from 55 preoperatively to 70 at follow-up. Subjectively, 87% of patients indicated that they were completely or mostly satisfied with the surgical outcome. One patient required another revision. The 2- to 11-year follow-up showed that the results of revision ACL reconstruction with a nonirradiated patellar tendon allograft were less favorable than those of a primary anterior cruciate ligament reconstruction, with a lower subjective satisfaction level and a higher percentage of patients with grade 1+ or higher pivot-shift results. However, when compared with previously published reports, our results were comparable and underscore that revision anterior cruciate ligament surgery should be approached with tempered enthusiasm and careful preoperative counseling, and considered as a salvage procedure. Level IV.
... keep your back straight. Using your front leg, push back into the starting position. Repeat on the other ... your back sag. Press into your arms to push yourself back up. If it is too hard to do ...
Crutches and children - stairs
... Put the good foot on the step and push up. Push down hard on the crutches to help lift ... Updated by: C. Benjamin Ma, MD, Professor, Chief, Sports Medicine and Shoulder Service, UCSF Department of Orthopaedic ...
A three-dimensional computerized isometric strength measurement system.
Black, Nancy L; Das, Biman
2007-05-01
The three-dimensional Computerized Isometric Strength Measurement System (CISMS) reliably and accurately measures isometric pull and push strengths in work spaces of paraplegic populations while anticipating comparative studies with other populations. The main elements of the system were: an extendable arm, a vertical supporting track, a rotating platform, a force transducer, stability sensors and a computerized data collection interface. The CISMS with minor modification was successfully used to measure isometric push-up and pull-down strengths of paraplegics and isometric push, pull, push-up and pull-down strength in work spaces for seated and standing able-bodied populations. The instrument has satisfied criteria of versatility, safety and comfort, ease of operation, and durability. Results are accurate within 2N for aligned forces. Costing approximately $1,500 (US) including computer, the system is affordable and accurate for aligned isometric strength measurements.
INTERSESSION RELIABILITY OF UPPER EXTREMITY ISOKINETIC PUSH-PULL TESTING.
Riemann, Bryan L; Davis, Sarah E; Huet, Kevin; Davies, George J
2016-02-01
Based on the frequency pushing and pulling patterns are used in functional activities, there is a need to establish an objective method of quantifying the muscle performance characteristics associated with these motions, particularly during the later stages of rehabilitation as criteria for discharge. While isokinetic assessment offers an approach to quantifying muscle performance, little is known about closed kinetic chain (CKC) isokinetic testing of the upper extremity (UE). To determine the intersession reliability of isokinetic upper extremity measurement of pushing and pulling peak force and average power at slow (0.24 m/s), medium (0.43 m/s) and fast (0.61 m/s) velocities in healthy young adults. The secondary purpose was to compare pushing and pulling peak force (PF) and average power (AP) between the upper extremity limbs (dominant, non-dominant) across the three velocities. Twenty-four physically active men and women completed a test-retest (>96 hours) protocol in order to establish isokinetic UE CKC reliability of PF and AP during five maximal push and pull repetitions at three velocities. Both limb and speed orders were randomized between subjects. High test-retest relative reliability using intraclass correlation coefficients (ICC2, 1) were revealed for PF (.91-.97) and AP (.85-.95) across velocities, limbs and directions. PF typical error (% coefficient of variation) ranged from 6.1% to 11.3% while AP ranged from 9.9% to 26.7%. PF decreased significantly (p < .05) as velocity increased whereas AP increased as velocity increased. PF and AP during pushing were significantly greater than pulling at all velocities, however the push-pull differences in PF became less as velocity increased. There were no significant differences identified between the dominant and nondominant limbs. Isokinetically derived UE CKC push-pull PF and AP are reliable measures. The lack of limb differences in healthy normal participants suggests that clinicians can consider bilateral comparisons when interpreting test performance. The increase in pushing PF and AP compared to pulling can be attributed to the muscles involved and the frequency that pushing patterns are used during functional activities. 3.
Push-pull with recovery stage high-voltage DC converter for PV solar generator
NASA Astrophysics Data System (ADS)
Nguyen, The Vinh; Aillerie, Michel; Petit, Pierre; Pham, Hong Thang; Vo, Thành Vinh
2017-02-01
A lot of systems are basically developed on DC-DC or DC-AC converters including electronic switches such as MOS or bipolar transistors. The limits of efficiency are quickly reached when high output voltages and high input currents are needed. This work presents a new high-efficiency-high-step-up based on push-pull DC-DC converter integrating recovery stages dedicated to smart HVDC distributed architecture in PV solar energy production systems. Appropriate duty cycle ratio assumes that the recovery stage work with parallel charge and discharge to achieve high step-up voltage gain. Besides, the voltage stress on the main switch is reduced with a passive clamp circuit and thus, low on-state resistance Rdson of the main switch can be adopted to reduce conduction losses. Thus, the efficiency of a basic DC-HVDC converter dedicated to renewable energy production can be further improved with such topology. A prototype converter is developed, and experimentally tested for validation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vaughn, Mark R.; Montague, Stephen
A push plate that includes springs in the form of cantilever flexures and an inspection window is disclosed. The push plate provides a known, uniform, down force and minimal torque to a package to be tested. The cantilevers have a known, calculable down force producing stiffness. The window provides for viewing of the package during testing.
Lubans, David R; Smith, Jordan J; Harries, Simon K; Barnett, Lisa M; Faigenbaum, Avery D
2014-05-01
The aim of this study was to describe the development and assess test-retest reliability and construct validity of the Resistance Training Skills Battery (RTSB) for adolescents. The RTSB provides an assessment of resistance training skill competency and includes 6 exercises (i.e., body weight squat, push-up, lunge, suspended row, standing overhead press, and front support with chest touches). Scoring for each skill is based on the number of performance criteria successfully demonstrated. An overall resistance training skill quotient (RTSQ) is created by adding participants' scores for the 6 skills. Participants (44 boys and 19 girls, mean age = 14.5 ± 1.2 years) completed the RTSB on 2 occasions separated by 7 days. Participants also completed the following fitness tests, which were used to create a muscular fitness score (MFS): handgrip strength, timed push-up, and standing long jump tests. Intraclass correlation (ICC), paired samples t-tests, and typical error were used to assess test-retest reliability. To assess construct validity, gender and RTSQ were entered into a regression model predicting MFS. The rank order repeatability of the RTSQ was high (ICC = 0.88). The model explained 39% of the variance in MFS (p ≤ 0.001) and RTSQ (r = 0.40, p ≤ 0.001) was a significant predictor. This study has demonstrated the construct validity and test-retest reliability of the RTSB in a sample of adolescents. The RTSB can reliably rank participants in regards to their resistance training competency and has the necessary sensitivity to detect small changes in resistance training skill proficiency.
ERIC Educational Resources Information Center
Adams, Megan; Fleer, Marilyn
2016-01-01
Historically, "free play" in many European heritage communities has been a valued practice. However, political imperatives have challenged these beliefs and necessitated a more academic curriculum to raise standards, resulting in a "push-down" curriculum. By contrast, many Asia-Pacific communities have increasingly included…
NASA Astrophysics Data System (ADS)
Paradis, Charles J.; McKay, Larry D.; Perfect, Edmund; Istok, Jonathan D.; Hazen, Terry C.
2018-03-01
The analytical solution describing the one-dimensional displacement of the center of mass of a tracer during an injection, drift, and extraction test (push-pull test) was expanded to account for displacement during the injection phase. The solution was expanded to improve the in situ estimation of effective porosity. The truncated equation assumed displacement during the injection phase was negligible, which may theoretically lead to an underestimation of the true value of effective porosity. To experimentally compare the expanded and truncated equations, single-well push-pull tests were conducted across six test wells located in a shallow, unconfined aquifer comprised of unconsolidated and heterogeneous silty and clayey fill materials. The push-pull tests were conducted by injection of bromide tracer, followed by a non-pumping period, and subsequent extraction of groundwater. The values of effective porosity from the expanded equation (0.6-5.0%) were substantially greater than from the truncated equation (0.1-1.3%). The expanded and truncated equations were compared to data from previous push-pull studies in the literature and demonstrated that displacement during the injection phase may or may not be negligible, depending on the aquifer properties and the push-pull test parameters. The results presented here also demonstrated the spatial variability of effective porosity within a relatively small study site can be substantial, and the error-propagated uncertainty of effective porosity can be mitigated to a reasonable level (< ± 0.5%). The tests presented here are also the first that the authors are aware of that estimate, in situ, the effective porosity of fine-grained fill material.
Tredrea, Matthew; Dascombe, Ben; Sanctuary, Colin E; Scanlan, Aaron Terrence
2017-10-01
This study aimed to identify attributes that discriminate selected from non-selected players and predict selection into a rugby league development programme in older adolescent players. Anthropometric, performance and psychological attributes were measured in under-16 (N = 100) and under-18 (N = 60) rugby league players trialling for selection into a development programme with a professional Australian club. Sprint times (P < 0.001), predicted VO 2max (P = 0.002) and push-ups 1 min (P = 0.004) were superior in selected under-16 players, and sprint times (P ≤ 0.045), push-ups 1 min (P < 0.001) and chin-ups 1 min (P = 0.013) were superior in selected under-18 players. Further, 10-m sprint (β = -7.706, standard error [SE] = 2.412), VO 2max (β = 0.168, SE = 0.052) and body mass (β = 0.071, SE = 0.023) significantly predicted selection (R 2 = 0.339) in under-16 players, while push-ups 1 min (β = 0.564, SE = 0.250), 10-m sprint (β = -68.477, SE = 28.107), body mass (β = 0.360, SE = 0.155) and chronological age (β = -3.577, SE = 1.720) significantly predicted selection (R 2 = 0.894) in under-18 players. These findings emphasise the importance of performance attributes in junior rugby league and indicate talent identification test batteries should be age-specific in older adolescent players.
RSA and registries: the quest for phased introduction of new implants.
Nelissen, Rob G H H; Pijls, Bart G; Kärrholm, Johan; Malchau, Henrik; Nieuwenhuijse, Marc J; Valstar, Edward R
2011-12-21
Although the overall survival of knee and hip prostheses at ten years averages 90%, recent problems with several hip and knee prostheses have illustrated that the orthopaedic community, industry, and regulators can still further improve patient safety. Given the early predictive properties of roentgen stereophotogrammetric analysis (RSA) and the meticulous follow-up of national joint registries, these two methods are ideal tools for such a phased clinical introduction. In this paper, we elaborate on the predictive power of RSA within a two-year follow-up after arthroplasty and its relationship to national joint registries. The association between RSA prosthesis-migration data and registry data is evaluated. The five-year rate of revision of RSA-tested total knee replacements was compared with that of non-RSA-tested total knee replacements. Data were extracted from the published results of the national joint registries of Sweden, Australia, and New Zealand. There was a 22% to 35% reduction in the number of revisions of RSA-tested total knee replacements as compared with non-RSA-tested total knee replacements in the national joint registries. Assuming that the total cost of total knee arthroplasty is $37,000 in the United States, a 22% to 35% reduction in the number of revisions (currently close to 55,000 annually) could lead to an estimated annual savings of over $400 million to the health-care system. The phased clinical introduction of new prostheses with two-year RSA results as a qualitative tool could lead to better patient care and could reduce the costs associated with revision total knee arthroplasty. Follow-up in registries is necessary to substantiate these results and to improve post-market surveillance.
Designing a warm-up protocol for elite bob-skeleton athletes.
Cook, Christian; Holdcroft, Danny; Drawer, Scott; Kilduff, Liam P
2013-03-01
To investigate how different warm-ups influenced subsequent sled-pull sprint performance in Olympic-level bob-skeleton athletes as part of their preparation for the 2010 Winter Olympics. Three female and 3 male athletes performed 5 different randomized warm-ups of differing intensities, durations, and timing relative to subsequent testing, each 2 days apart, all repeated twice. After warm-ups, testing on a sled-pull sprint over 20 m, 3 repeats 3 min apart, took place. Performance testing showed improvement (P < .001, ES > 1.2) with both increasing intensity of warm-up and closeness of completion to testing, with 20-m sled sprinting being 0.1-0.25 s faster in higher-intensity protocols performed near testing In addition, supplementing the warm-ups by wearing of a light survival coat resulted in further performance improvement (P = .000, ES 1.8). Changing timing and intensity of warm-up and using an ancillary passive heat-retention device improved sprint performance in Olympic-level bob-skeleton athletes. Subsequent adoption of these on the competitive circuit was associated with a seasonal improvement in push times and was ultimately implemented in the 2010 Winter Olympics.
Horbert, Victoria; Xin, Long; Foehr, Peter; Brinkmann, Olaf; Bungartz, Matthias; Burgkart, Rainer H; Graeve, T; Kinne, Raimund W
2018-02-01
Objective Limitations of matrix-assisted autologous chondrocyte implantation to regenerate functional hyaline cartilage demand a better understanding of the underlying cellular/molecular processes. Thus, the regenerative capacity of a clinically approved hydrogel collagen type I implant was tested in a standardized bovine cartilage punch model. Methods Cartilage rings (outer diameter 6 mm; inner defect diameter 2 mm) were prepared from the bovine trochlear groove. Collagen implants (± bovine chondrocytes) were placed inside the cartilage rings and cultured up to 12 weeks. Cartilage-implant constructs were analyzed by histology (hematoxylin/eosin; safranin O), immunohistology (aggrecan, collagens 1 and 2), and for protein content, RNA expression, and implant push-out force. Results Cartilage-implant constructs revealed vital morphology, preserved matrix integrity throughout culture, progressive, but slight proteoglycan loss from the "host" cartilage or its surface and decreasing proteoglycan release into the culture supernatant. In contrast, collagen 2 and 1 content of cartilage and cartilage-implant interface was approximately constant over time. Cell-free and cell-loaded implants showed (1) cell migration onto/into the implant, (2) progressive deposition of aggrecan and constant levels of collagens 1 and 2, (3) progressively increased mRNA levels for aggrecan and collagen 2, and (4) significantly augmented push-out forces over time. Cell-loaded implants displayed a significantly earlier and more long-lasting deposition of aggrecan, as well as tendentially higher push-out forces. Conclusion Preserved tissue integrity and progressively increasing cartilage differentiation and push-out forces for up to 12 weeks of cultivation suggest initial cartilage regeneration and lateral bonding of the implant in this in vitro model for cartilage replacement materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Semprini, L.; Istok, J.
'The objective of this research is to develop a unique method of using naturally occurring radon-222 as a tracer for locating and quantitatively describing the presence of subsurface NAPL contamination. The research will evaluate using radon as an inexpensive, yet highly accurate, means of detecting NAPL contamination and assessing the effectiveness of NAPL remediation. Laboratory, field, and modeling studies are being performed to evaluate this technique, and to develop methods for its successful implementation in practice. This report summarizes work that has been accomplished after 1-year of a 3-year project. The research to date has included radon tracer tests inmore » physical aquifer models (PAMs) and field studies at Site 300 of the Lawrence Livermore National Laboratory, CA, and Site 100D at Hanford DOE Facility, WA. The PAM tests have evaluated the ability of radon as a tracer to monitor the remediation of TCE NAPL contamination using surfactant treatment, and oxidation with permanganate. The surfactant tests were performed in collaboration with Dr. Jack Istok and Dr. Jennifer Field and their EMSP project ``In-situ, Field-Scale Evaluation of Surfactant Enhanced DNAPL Recovery Using a Single-Well-Push-Pull Test.'''' This collaboration enabled the EMSP radon project to make rapid progress. The PAM surfactant tests were performed in a radial flow geometry to simulate the push-pull-method that is being developed for surfactant field tests. The radon tests were easily incorporated into these experiments, since they simply rely on measuring the natural radon present in the subsurface fluids. Two types of radon tests were performed: (1) static tests where radon was permitted to build-up to steady-state concentrations in the pore fluids and the groundwater concentrations were monitored, and (2) dynamic tests were the radon response during push-pull surfactant tests was measured. Both methods were found to be useful in determining how NAPL remediation was progressing.'« less
Analytical solutions for efficient interpretation of single-well push-pull tracer tests
Single-well push-pull tracer tests have been used to characterize the extent, fate, and transport of subsurface contamination. Analytical solutions provide one alternative for interpreting test results. In this work, an exact analytical solution to two-dimensional equations descr...
Bartolomei, Sandro; Nigro, Federico; Ruggeri, Sandro; Lanzoni, Ivan Malagoli; Ciacci, Simone; Merni, Franco; Sadres, Eliahu; Hoffman, Jay R; Semprini, Gabriele
2018-03-06
The purpose of the present study was to validate the ballistic push-up test performed with hands on a force plate (BPU) as a method to measure upper-body power. Twenty-eight experienced resistance trained men (age = 25.4 ± 5.2 y; body mass = 78.5 ± 9.0 kg; body height = 179.6 ± 7.8 cm) performed, two days apart, a bench press 1RM test and upper-body power tests. Mean power and peak power were assessed using the bench press throw test (BT) and the BPU test performed in randomized order. The area under the force/power curve (AUC) obtained at BT was also calculated. Power expressed at BPU was estimated using a time-based prediction equation. Mean force and the participant's body weight were used to predict the bench press 1RM. Pearson product moment correlations were used to examine relationships between the power assessment methods and between the predicted 1RM bench and the actual value. Large correlations (0.79; p < 0.001) were found between AUC and mean power expressed at BPU. Large correlations were also detected between mean power and peak power expressed at BT and BPU (0.75; p < 0.001 and 0.74; p < 0.001, respectively). Very large correlations (0.87; p < 0.001) were found between the 1RM bench and the 1RM predicted by the BPU. Results of the present study indicate that BPU represents a valid and reliable method to estimate the upper-body power in resistance-trained individuals.
Schwabe, P; Märdian, S; Perka, C; Schaser, K-D
2016-04-01
Reconstruction/stable fixation of the acetabular columns to create an adequate periacetabular requirement for the implantation of a revision cup. Displaced/nondisplaced fractures with involvement of the posterior column. Resulting instability of the cup in an adequate bone stock situation. Periprosthetic acetabulum fractures with inadequate bone stock. Extended periacetabular defects with loss of anchorage options. Isolated periprosthetic fractures of the anterior column. Septic loosening. Dorsal approach. Dislocation of hip. Mechanical testing of inlaying acetabular cup. With unstable cup situation explantation of the cup, fracture fixation of acetabulum with dorsal double plate osteosynthesis along the posterior column. Cup revision. Hip joint reposition. Early mobilization; partial weight bearing for 12 weeks. Thrombosis prophylaxis. Clinical and radiological follow-ups. Periprosthetic acetabular fracture in 17 patients with 9 fractures after primary total hip replacement (THR), 8 after revision THR. Fractures: 12 due to trauma, 5 spontaneously; 7 anterior column fractures, 5 transverse fractures, 4 posterior column fractures, 1 two column fracture after hemiendoprosthesis. 5 type 1 fractures and 12 type 2 fractures. Operatively treated cases (10/17) received 3 reinforcement ring, 2 pedestal cup, 1 standard revision cup, cup-1 cage construct, 1 ventral plate osteosynthesis, 1 dorsal plate osteosynthesis, and 1 dorsal plate osteosynthesis plus cup revision (10-month Harris Hip Score 78 points). Radiological follow-up for 10 patients: consolidation of fractures without dislocation and a fixed acetabular cup. No revision surgeries during follow-up; 2 hip dislocations, 1 transient sciatic nerve palsy.
Shin, A-Reum; Lee, Ji-Hyun; Kim, Da-Eun; Cynn, Heon-Seock
2018-04-01
Scapular winging (SW) is defined as increased prominence of the whole medial border of the scapula. Many researchers recently recommended knee push-up plus (KPP) for enhancing serratus anterior (SA) activation. However, during push-up plus, thoracic kyphosis (TK) may usually occur as a compensatory movement. Thus, the purpose of this study was to investigate the effect of Thera-Band application during KPP on rectus abdominis (RA) activity, TK angle (TKA), SA activity, and amount of SW in subjects with SW.Fifteen subjects performed KPP with Thera-Band applied to different posterior body parts (no Thera-Band, in the occiput, and in the thoracic region). Electromyography was used to record the RA and SA activities. Image J software was used to calculate the compensatory TKA during KPP, and a scapulometer was used to measure SW in the quadruped position. One-way repeated-measures analysis of variance was used to test for significance.KPP with Thera-Band in the occiput showed significantly lower RA activity (P = .001) and TKA (P < .001) than KPP with no Thera-Band. SA activity (P = .020, P = .047) and SW (P < .001, P < .001) were significantly lower with Thera-Band applied to the occiput and thoracic regions than in KPP with no Thera-Band.Thera-Band applied to the occiput and thorax can be beneficial as it decreases RA and SA muscle activity and reduces TKA and SW during KPP in subjects with SW.
Choi, Woo-Jeong; Yoon, Tae-Lim; Choi, Sil-Ah; Lee, Ji-Hyun; Cynn, Heon-Seock
2017-07-01
The aim of the present study was to determine whether the application of isometric horizontal abduction (IHA) differentially affected two weight-bearing push-up plus exercises by examining activation of the scapulothoracic muscles in subjects with scapular winging. Fifteen male subjects performed standard push-up plus (SPP) and wall push-up plus (WPP), with and without IHA. Two-way analyses of variance using two within-subject factors were used to determine the statistical significance of observed differences in upper trapezius (UT), pectoralis major (PM), and serratus anterior (SA) muscle activities and UT/SA and PM/SA muscle activity ratios. UT and SA muscle activities were greater during SPP than WPP. PM muscle activity was lower with IHA application. The UT/SA and PM/SA muscle activity ratios were lower during SPP than WPP. The PM/SA muscle activity ratio was lower with IHA application. The results suggest that IHA application using a Thera-Band can effectively reduce PM muscle activity during SPP and WPP exercises. Moreover, the SPP exercise can be used to increase UT and SA muscle activity and reduce the UT/SA and PM/SA muscle activity ratios in subjects with scapular winging. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ajisafe, Toyin; Garcia, Theresa; Fanchiang, Hsin-Chen
2018-01-01
This study investigated current obesity prevalence and associations between musculoskeletal fitness test scores and the odds of being underweight, overweight, or obese compared to having a healthy weight in elementary school children in Corpus Christi, Texas. The sample analyzed consisted of 492 public elementary school children between kindergarten and fifth grade. Their ages ranged from 5 to 11 years. Trunk lift, 90° push-up, curl-up, and back saver sit and reach tests were administered. Weight status was determined using BMI scores and the CDC growth charts. Obesity prevalence remains high among elementary school-aged children in Corpus Christi, Texas. Higher 90° push-up test scores were most consistently associated with decreased odds of being obese as compared to being overweight and having healthy weight except in kindergarten. Conversely, higher trunk lift test scores were associated with increased odds of being obese in second and fourth grades. When children achieved the minimum score to be classified in the Healthy Fitness Zone, those with healthy weight had similarly low musculoskeletal fitness (i.e., abdominal strength and endurance, hamstring flexibility, and trunk extensor strength and flexibility) as peers with overweight and obesity, especially in the lower grades. It was concluded that increased obesity prevalence in higher grades may be precipitated (at least in part) by low musculoskeletal fitness in the lower grades, especially kindergarten. Given previous associations in the literature, low musculoskeletal fitness may be symptomatic of poor motor skill competence in the current sample. These findings suggest a need for early and focused school-based interventions that leverage both known and novel strategies to combat pediatric obesity in Corpus Christi. PMID:29872650
Ajisafe, Toyin; Garcia, Theresa; Fanchiang, Hsin-Chen
2018-01-01
This study investigated current obesity prevalence and associations between musculoskeletal fitness test scores and the odds of being underweight, overweight, or obese compared to having a healthy weight in elementary school children in Corpus Christi, Texas. The sample analyzed consisted of 492 public elementary school children between kindergarten and fifth grade. Their ages ranged from 5 to 11 years. Trunk lift, 90° push-up, curl-up, and back saver sit and reach tests were administered. Weight status was determined using BMI scores and the CDC growth charts. Obesity prevalence remains high among elementary school-aged children in Corpus Christi, Texas. Higher 90° push-up test scores were most consistently associated with decreased odds of being obese as compared to being overweight and having healthy weight except in kindergarten. Conversely, higher trunk lift test scores were associated with increased odds of being obese in second and fourth grades. When children achieved the minimum score to be classified in the Healthy Fitness Zone, those with healthy weight had similarly low musculoskeletal fitness (i.e., abdominal strength and endurance, hamstring flexibility, and trunk extensor strength and flexibility) as peers with overweight and obesity, especially in the lower grades. It was concluded that increased obesity prevalence in higher grades may be precipitated (at least in part) by low musculoskeletal fitness in the lower grades, especially kindergarten. Given previous associations in the literature, low musculoskeletal fitness may be symptomatic of poor motor skill competence in the current sample. These findings suggest a need for early and focused school-based interventions that leverage both known and novel strategies to combat pediatric obesity in Corpus Christi.
The sit up test to exhaustion as a test for muscular endurance evaluation.
Bianco, Antonino; Lupo, Corrado; Alesi, Marianna; Spina, Serena; Raccuglia, Margherita; Thomas, Ewan; Paoli, Antonio; Palma, Antonio
2015-01-01
The aim of this study was to examine the sit up test to exhaustion as a field test for muscular endurance evaluation in a sample of sedentary people of both sexes. A cross-sectional study was performed. Three-hundred-eighty-one participants volunteered for the study (28.5 ± 10.0 years; 168.2 ± 8.9 cm; 65.1 ± 11.1 kg), of which 194 males (27.5 ± 10.2 years; 173.6 ± 7.0 cm; 71.2 ± 5.2 kg) and 187 females (29.6 ± 10.1 years; 162.6 ± 7.1 cm; 58.7 ± 8.9 kg). Each subject voluntarily and randomly performed: a sit up test (SUT), a push up test (PUT), and a free weight squat test (ST), all till exhaustion. A multiple regression analysis was adopted for data analysis. Subsequently a percentile model for muscle endurance was developed. The 25th, 50th, and 75th percentile were identified as upper limit for low muscular endurance, average muscular endurance, and lower limit for high muscular endurance, respectively. Considering the sit up test as the dependent variable, the coefficients (R(2) = 0.23; r = 0.49; p < 0.001), and (R(2) = 0.31; r = 0.57; p < 0.001) emerged from a multiple regression analysis applied with respect to the push up test and the squat test, respectively. Gender stratification showed regression coefficients of (R(2) = 0.19; r = 0.44; p < 0.001) for SUT vs. PUT, and (R(2) = 0.30; r = 0.56; p < 0.001) for SUT vs. ST in male; and (R(2) = 0.23; r = 0.49; p < 0.001) for SUT vs. PUT, and (R(2) = 0.34; r = 0.59; p < 0.001) for SUT vs. ST in female. The SUT showed low inter-relation with the other proposed tests indicating that the adoption of a single test for the global evaluation of muscle endurance is not the optimal approach. Moreover, the SUT was found to be inexpensive, safe, and appropriate for core muscle endurance measurement for both male and female.
Micro/nano-mechanical test system employing tensile test holder with push-to-pull transformer
Oh, Yunje; Cyrankowski, Edward; Shan, Zhiwei; Asif, Syed Amanula Syed
2013-05-07
A micromachined or microelectromechanical system (MEMS) based push-to-pull mechanical transformer for tensile testing of micro-to-nanometer scale material samples including a first structure and a second structure. The second structure is coupled to the first structure by at least one flexible element that enables the second structure to be moveable relative to the first structure, wherein the second structure is disposed relative to the first structure so as to form a pulling gap between the first and second structures such that when an external pushing force is applied to and pushes the second structure in a tensile extension direction a width of the pulling gap increases so as to apply a tensile force to a test sample mounted across the pulling gap between a first sample mounting area on the first structure and a second sample mounting area on the second structure.
Micro/nano-mechanical test system employing tensile test holder with push-to-pull transformer
Oh, Yunje; Cyrankowski, Edward; Shan, Zhiwei; Syed Asif, Syed Amanula
2014-07-29
A micromachined or microelectromechanical system (MEMS) based push-to-pull mechanical transformer for tensile testing of micro-to-nanometer scale material samples including a first structure and a second structure. The second structure is coupled to the first structure by at least one flexible element that enables the second structure to be moveable relative to the first structure, wherein the second structure is disposed relative to the first structure so as to form a pulling gap between the first and second structures such that when an external pushing force is applied to and pushes the second structure in a tensile extension direction a width of the pulling gap increases so as to apply a tensile force to a test sample mounted across the pulling gap between a first sample mounting area on the first structure and a second sample mounting area on the second structure.
Subjective vs Objective Accommodative Amplitude: Preschool to Presbyopia
Anderson, Heather A.; Stuebing, Karla K.
2014-01-01
Purpose This study compared subjective and objective accommodative amplitudes to characterize changes from preschool to presbyopia. Methods Monocular accommodative amplitude was measured with three techniques in random order (subjective push-up, objective minus lens stimulated, and objective proximal stimulated) on 236 subjects 3–64 years using a 1.5mm letter. Subjective push-up amplitudes were the dioptric distance at which the target first blurred along a near-point rod. Objective minus lens stimulated amplitudes were the greatest accommodative response obtained by Grand Seiko autorefraction as subjects viewed the stimulus at 33cm through increasing minus lens powers. Objective proximal stimulated amplitudes were the greatest accommodative response obtained by Grand Seiko autorefraction as subjects viewed the stimulus at increasing proximity from 40cm up to 3.33cm. Results In comparison with subjective push-up amplitudes, objective amplitudes were lower at all ages, with the most dramatic difference occurring in the 3–5 year group (subjective push-up = 16.00 ± 4.98D versus objective proximal stimulated = 7.94 ± 2.37D and objective lens stimulated = 6.20 ± 1.99D). Objective proximal and lens stimulated amplitudes were largest in the 6–10 year group (8.81 ± 1.24D and 8.05 ± 1.82D, respectively) and gradually decreased until the fourth decade of life when a rapid decline to presbyopia occurred. There was a significant linear relationship between objective techniques (y = 0.74 + 0.96x, R2 = 0.85, p<0.001) with greater amplitudes measured for the proximal stimulated technique (mean difference = 0.55D). Conclusions Objective measurements of accommodation demonstrate that accommodative amplitude is substantially less than that measured by the subjective push-up technique, particularly in young children. These findings have important clinical implications for the management of uncorrected hyperopia. PMID:25602235
Kneeshaw, T.A.; McGuire, J.T.; Smith, E.W.; Cozzarelli, I.M.
2007-01-01
This paper presents small-scale push-pull tests designed to evaluate the kinetic controls on SO42 - reduction in situ at mixing interfaces between a wetland and aquifer impacted by landfill leachate at the Norman Landfill research site, Norman, OK. Quantifying the rates of redox reactions initiated at interfaces is of great interest because interfaces have been shown to be zones of increased biogeochemical transformations and thus may play an important role in natural attenuation. To mimic the aquifer-wetland interface and evaluate reaction rates, SO42 --rich anaerobic aquifer water (??? 100 mg / L SO42 -) was introduced into SO42 --depleted wetland porewater via push-pull tests. Results showed SO42 - reduction was stimulated by the mixing of these waters and first-order rate coefficients were comparable to those measured in other push-pull studies. However, rate data were complex involving either multiple first-order rate coefficients or a more complex rate order. In addition, a lag phase was observed prior to SO42 - reduction that persisted until the mixing interface between test solution and native water was recovered, irrespective of temporal and spatial constraints. The lag phase was not eliminated by the addition of electron donor (acetate) to the injected test solution. Subsequent push-pull tests designed to elucidate the nature of the lag phase support the importance of the mixing interface in controlling terminal electron accepting processes. These data suggest redox reactions may occur rapidly at the mixing interface between injected and native waters but not in the injected bulk water mass. Under these circumstances, push-pull test data should be evaluated to ensure the apparent rate is actually a function of time and that complexities in rate data be considered. ?? 2007 Elsevier Ltd. All rights reserved.
Ground reaction force characteristics of Tai Chi push hand.
Chang, Yao-Ting; Chang, Jia-Hao; Huang, Chen-Fu
2014-01-01
Push Hand is an advanced training technique for the Yang-style old frame 108 forms Tai Chi Chuan. It is performed by two practitioners. To clarify how people use forces during Push Hand training, it is important to review the ground reaction force (GRF). Here, we quantify the characteristics of the GRF during Push Hand training. Kinematic data and GRF data from 10 Tai Chi Chuan practitioners (29.9 ± 7.87 years) were synchronously recorded using a three-dimensional motion analysis system (200 frames · s(-1)) and three-dimensional force plates (1000 Hz). The resultant GRF for both feet for the 0%, 50% and 100% phases of attack and defence were compared to body weight using a paired-samples t-test. The differences in the resultant GRF between the 0%, 50% and 100% phases of attack and defence were tested by one-way repeated-measures ANOVA. The significance level was set to 0.05. The total resultant GRF was almost equal to the participant's body weight in push hand. This result was consistent throughout the entire push hand process. Our results revealed that the GRF was comparable to the body weight, implying that practitioners do not push or resist their opponents during the push hand process.
Are single-well "push-pull" tests suitable tracer methods for aquifer characterization?
NASA Astrophysics Data System (ADS)
Hebig, Klaus; Zeilfelder, Sarah; Ito, Narimitsu; Machida, Isao; Scheytt, Traugott; Marui, Atsunao
2013-04-01
Recently, investigations were conducted for geological and hydrogeological characterisation of the sedimentary coastal basin of Horonobe (Hokkaido, Japan). Coastal areas are typical geological settings in Japan, which are less tectonically active than the mountain ranges. In Asia, and especially in Japan, these areas are often densely populated. Therefore, it is important to investigate the behaviour of solutes in such unconsolidated aquifers. In such settings sometimes only single boreholes or groundwater monitoring wells are available for aquifer testing for various reasons, e.g. depths of more than 100 m below ground level and slow groundwater velocities due to density driven flow. A standard tracer test with several involved groundwater monitoring wells is generally very difficult or even not possible at these depths. One of the most important questions in our project was how we can obtain information about chemical and hydraulic properties in such aquifers. Is it possible to characterize solute transport behaviour parameters with only one available groundwater monitoring well or borehole? A so-called "push-pull" test may be one suitable method for aquifer testing with only one available access point. In a push-pull test a known amount of several solutes including a conservative tracer is injected into the aquifer ("push") and afterwards extracted ("pull"). The measured breakthrough curve during the pumping back phase can then be analysed. This method has already been used previously with various aims, also in the recent project (e.g. Hebig et al. 2011, Zeilfelder et al. 2012). However, different test setups produced different tracer breakthrough curves. As no systematic evaluation of this aquifer tracer test method was done so far, nothing is known about its repeatability. Does the injection and extraction rate influence the shape of the breakthrough curve? Which role plays the often applied "chaser", which is used to push the test solution out from the borehole and gravel pack? How does density difference between the original groundwater and the test solution influence the tracer breakthrough curves? To solve these questions, seven push-pull tests were performed under controlled boundary conditions in the same well DD-2 (100 m depth). Only single parameters, as e.g. flow rate or salinization of the test solution, were varied during the experiments. By conducting these different test setups, conclusions could be drawn about the application of the push-pull method under different settings. References: Hebig, K.H., Ito, N., Scheytt, T.J. & Marui, A. (2011). Hydraulic and hydrochemical characterization of deep coastal sedimentary basins by single-well Push-Pull tests. GSA Annual Meeting, 9-12 October 2011, Minneapolis, USA. Zeilfelder, S., Ito, N., Marui, A., Hebig, K. & Scheytt, T. (2012). Push-Pull-Test und Tracer-Test in ei-nem tiefen Grundwasserleiter in Kameoka, Japan. Kurzfassung in: Liedl, R., Burghardt, D., Simon, E., Reimann, T. & Kaufmann-Knoke (Hg.). Grundwasserschutz und Grundwassernutzung. Tagung der Fachsektion Hydrogeologie in der DGG (FH-DGG). 16. - 20. Mai 2012, Dresden. Kurfassungen der Vorträge und Poster. Schriftenreihe der DGG, Heft 78, S. 192.
Association of Quality Physical Education Teaching with Students’ Physical Fitness
Chen, Weiyun; Mason, Steve; Hypnar, Andrew; Hammond-Bennett, Austin
2016-01-01
This study examined the extent to which four essential dimensions of quality physical education teaching (QPET) were associated with healthy levels of physical fitness in elementary school students. Participants were nine elementary PE teachers and 1, 201 fourth- and fifth-grade students who were enrolled in nine elementary schools. The students’ physical fitness were assessed using four FITNESSGRAM tests. The PE teachers’ levels of QPET were assessed using the Assessing Quality Teaching Rubrics (AQTR). The AQTR consisted of four essential dimensions including Task Design, Task Presentation, Class Management, and Instructional Guidance. Codes were confirmed through inter-rater reliability (82.4% and 84.5%). Data were analyzed through descriptive statistics, multiple R-squared regression models, and independent sample t-tests. The four essential teaching dimensions of QPET were significantly associated with the students’ cardiovascular endurance, muscular strength and endurance, and flexibility. However, they accounted for relatively low percentage of the total variance in PACER test, followed by Curl-up test, while explaining very low portions of the total variance in Push-up and Trunk Lift tests. This study indicated that the students who had experienced high level of QPET were more physically fit than their peers who did not have this experience in PACER and Curl-up tests, but not in Push-up and Trunk lift tests. In addition, the significant contribution of the four essential teaching dimensions to physical fitness components was gender-specific. It was concluded that the four teaching dimensions of QPET were significantly associated with students’ health-enhancing physical fitness. Key points Although Task Design, Task Presentation, Class Management, and Instructional Guidance has its unique and critical teaching components, each essential teaching dimensions is intertwined and immersed in teaching practices. Four essential teaching dimensions all significantly contributed to students’ health-enhancing physical fitness. Implementation of QPET in a lesson plays more significant role in contributing to improving girls’ cardiovascular endurance. Implementation of QPET in a lesson contributed significantly to improving boy’s abdominal, upper-body, and back extensor muscular strength and endurance as well as flexibility PMID:27274673
Computerized Numerical Control Test Item Bank.
ERIC Educational Resources Information Center
Reneau, Fred; And Others
This guide contains 285 test items for use in teaching a course in computerized numerical control. All test items were reviewed, revised, and validated by incumbent workers and subject matter instructors. Items are provided for assessing student achievement in such aspects of programming and planning, setting up, and operating machines with…
Field Evaluation of a Push-Pull System to Reduce Malaria Transmission
Menger, David J.; Omusula, Philemon; Holdinga, Maarten; Homan, Tobias; Carreira, Ana S.; Vandendaele, Patrice; Derycke, Jean-Luc; Mweresa, Collins K.; Mukabana, Wolfgang Richard; van Loon, Joop J. A.; Takken, Willem
2015-01-01
Malaria continues to place a disease burden on millions of people throughout the tropics, especially in sub-Saharan Africa. Although efforts to control mosquito populations and reduce human-vector contact, such as long-lasting insecticidal nets and indoor residual spraying, have led to significant decreases in malaria incidence, further progress is now threatened by the widespread development of physiological and behavioural insecticide-resistance as well as changes in the composition of vector populations. A mosquito-directed push-pull system based on the simultaneous use of attractive and repellent volatiles offers a complementary tool to existing vector-control methods. In this study, the combination of a trap baited with a five-compound attractant and a strip of net-fabric impregnated with micro-encapsulated repellent and placed in the eaves of houses, was tested in a malaria-endemic village in western Kenya. Using the repellent delta-undecalactone, mosquito house entry was reduced by more than 50%, while the traps caught high numbers of outdoor flying mosquitoes. Model simulations predict that, assuming area-wide coverage, the addition of such a push-pull system to existing prevention efforts will result in up to 20-fold reductions in the entomological inoculation rate. Reductions of such magnitude are also predicted when mosquitoes exhibit a high resistance against insecticides. We conclude that a push-pull system based on non-toxic volatiles provides an important addition to existing strategies for malaria prevention. PMID:25923114
Fifteen Year Follow-Up Geography Skills Test Administered in Indiana, 1987 and 2002
ERIC Educational Resources Information Center
Bein, F. L.; Hayes, James J.; Jones, Thomas G.
2009-01-01
After fifteen years of geographic education efforts, a baseline geography skills test was repeated in Indiana. In 2002, 2,278 students in college freshman geography courses were tested with a revision of the National Council for Geographic Education Competency-Based Geography Test, Secondary Level Form II. The test measured geographic ability in…
Santtila, Matti; Pihlainen, Kai; Koski, Harri; Ojanen, Tommi; Kyröläinen, Heikki
2018-06-13
The physical fitness of male conscripts has decreased, and body mass increased during the last few decades, especially in Nordic countries. However, limited research-based reports are available concerning the physical fitness profiles of female recruits. Therefore, the purpose of this study was to investigate changes in physical fitness and body composition of female recruits entering voluntary Finnish military service between the years 2005 and 2015. Data were collected from the initial fitness tests performed in military units during the first 2 weeks of military service. A total of 3,875 healthy female recruits (19.9 ± 2.1 year) participated in the fitness tests. Fitness tests consisted 12-minute running test and muscle fitness tests, which were sit-ups, push-ups, and standing long jump. Increases in mean body mass (4.2%, p ≤ 0.01) and body mass index (3.8%, p < 0.01) were observed between 2005 and 2015. In addition, the proportion of overweight and obese female recruits increased by 12% (p ≤ 0.001). Mean endurance performance and overall muscle fitness remained unaltered during the study period, except for a decline in push-ups performance. However, the proportion of female recruits with poor endurance performance increased from 19.6% to 27.8% (p ≤ 0.001) between 2005 and 2015. Body mass was inversely associated with 12-minute running test distance (r = -0.35, p ≤ 0.001) and muscle fitness index (r = -0.25, p ≤ 0.001). In conclusion, the present study revealed that an increasing proportion of female recruits are overweight and/or have poor endurance performance, which are known risk factors for musculoskeletal injuries and premature discharge from military service. Therefore, specialized training programs should be designed specifically for female recruits with lower levels of fitness prior to military service.
Kojima, Hajime; Katoh, Masakazu; Shinoda, Shinsuke; Hagiwara, Saori; Suzuki, Tamie; Izumi, Runa; Yamaguchi, Yoshihiro; Nakamura, Maki; Kasahawa, Toshihiko; Shibai, Aya
2014-07-01
Three validation studies were conducted by the Japanese Society for Alternatives to Animal Experiments in order to assess the performance of a skin irritation assay using reconstructed human epidermis (RhE) LabCyte EPI-MODEL24 (LabCyte EPI-MODEL24 SIT) developed by the Japan Tissue Engineering Co., Ltd. (J-TEC), and the results of these studies were submitted to the Organisation for Economic Co-operation and Development (OECD) for the creation of a Test Guideline (TG). In the summary review report from the OECD, the peer review panel indicated the need to resolve an issue regarding the misclassification of 1-bromohexane. To this end, a rinsing operation intended to remove exposed chemicals was reviewed and the standard operating procedure (SOP) revised by J-TEC. Thereafter, in order to confirm general versatility of the revised SOP, a new validation management team was organized by the Japanese Center for the Validation of Alternative Methods (JaCVAM) to undertake a catch-up validation study that would compare the revised assay with similar in vitro skin irritation assays, per OECD TG No. 439 (2010). The catch-up validation and supplementary studies for LabCyte EPI-MODEL24 SIT using the revised SOPs were conducted at three laboratories. These results showed that the revised SOP of LabCyte EPI-MODEL24 SIT conformed more accurately to the classifications for skin irritation under the United Nations Globally Harmonised System of Classification and Labelling of Chemicals (UN GHS), thereby highlighting the importance of an optimized rinsing operation for the removal of exposed chemicals in obtaining consistent results from in vitro skin irritation assays. Copyright © 2013 John Wiley & Sons, Ltd.
Mumcu, Emre; Erdemir, Ugur; Topcu, Fulya Toksoy
2010-05-01
By means of a micro push-out test, this study compared the bond strengths of two types of fiber-reinforced posts cemented with luting cements based on two currently available adhesive approaches as well as evaluated their failure modes. Sixty extracted single-rooted human maxillary central incisor and canine teeth were sectioned below the cementoenamel junction, and the roots were endodontically treated. Following standardized post space preparation, the roots were divided into two fiber post groups and then further into three subgroups of 10 specimens each according to the luting cements. A push-out test was performed to measure regional bond strengths, and the fracture modes were evaluated using a stereomicroscope. At the root section, there were no statistically significant differences (p>0.05) in push-out bond strength among the tested luting cements. Nevertheless, the push-out bond strength values of glass fiber-reinforced posts were higher than those of carbon fiber-reinforced posts, irrespective of the adhesive approach used. On failure mode, the predominant failure mode was adhesive failure between dentin and the luting cement.
Getting up to speed. Execs detail IT needs, investments required to support an ACO.
Evans, Melanie
2012-02-20
The push for accountable care organizations means a push for more information technology that allows the sharing of data. So hospitals and other providers that are forming ACOs are feeling new urgency to ramp up their IT improvements. At Banner Health it means figuring out how to deal with independent physicians' "mishmash" of systems. "There has been an acceleration of interest," says Dr. John Hensing, left, Banner's chief medical officer.
Effective Size Analysis of the Diametral Compression (Brazil) Test Specimen
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jadaan, Osama M.; Wereszczak, Andrew A
2009-04-01
This study considers the finite element analysis (FEA) simulation and Weibull effective size analysis for the diametral compression (DC) or Brazil specimen loaded with three different push-rod geometries. Those geometries are a flat push-rod, a push-rod whose radius of curvature is larger than that for the DC specimen, and a push-rod whose radius of curvature matches that of the DC specimen. Such established effective size analysis recognizes that the tensile strength of structural ceramics is typically one to two orders of magnitude less than its compressive strength. Therefore, because fracture is much more apt to result from a tensile stressmore » than a compressive one, this traditional analysis only considers the first principal tensile stress field in the mechanically loaded ceramic component for the effective size analysis. The effective areas and effective volumes were computed as function of Weibull modulus using the CARES/Life code. Particular attention was devoted to the effect of mesh sensitivity and localized stress concentration. The effect of specimen width on the stress state was also investigated. The effects of push-rod geometry, the use of steel versus WC push-rods, and considering a frictionless versus no-slip interface between push-rod and specimen on the maximum stresses, where those stresses are located, and the effective area and effective volume results are described. Of the three push-rod geometries, it is concluded that the push-rod (made from WC rather than steel) whose radius of curvature matches that of the DC specimen is the most apt to cause fracture initiation within the specimen's bulk rather than at the loading interface. Therefore, its geometry is the most likely to produce a valid diametral compression strength test. However, the DC specimen remains inefficient in terms of its area and volume efficiencies; namely, the tensile strength of only a few percent of the specimen's entire area or volume is sampled. Given the high probability that a valid (or invalid) test can be proven by ceramic fractographic practices suggests that this test method and specimen is questionable for use with relatively strong structural ceramics.« less
An Overview of Direct Push Technology
1994-08-12
Figure 3.4). Zemo et. al. (1992) indicate this probe is first pushed to the target zone, then pulled up to open the screened section in 27 the same manner...28 * manufactured by QED Environmental Systems (Figure 3.5). Zemo et. al. (1992) indicate this sampler is also pushed to the required depth, then...Exhibition, HMC/Superfund, pp. 228-237, Dec. 1-3, 1992, Washington, D.C. Zemo , D. A., Delfino, J. D., Gallinatti, J. D., Baker, V. A., and Hilpert, L. R
Navarathne, Daminda; Skene, W G
2013-12-11
A series of symmetric and unsymmetric conjugated azomethines derived from cinnamaldehyde and 2,5-diaminothiophene-3,4-dicarboxylic acid diethyl ester were prepared. The optical, electrochemical, and spectroelectrochemical properties of the electronic push-pull and push-push triads were investigated. Their properties could be tuned contingent on the cinnamaldehyde's electron withdrawing and donating substituents. The push-push symmetric derivative exhibited positive solvatochromism with the absorbance spanning some 31 nm, depending on the solvent polarity. Solvent dependent spectroelectrochemistry was also found for the symmetric push-push azomethine. The color of the neutral state and radical cation spanned 215 nm. The most pronounced color transition of the purple colored material was found in dimethyl sulfoxide (DMSO), where the color bleached with electrochemical oxidation. This was a result of the absorbance shifting into the near infrared (NIR) and not from decomposition of the azomethine. Electrochromic devices with the azomethines possessing desired reversible oxidation and color changes in the visible were fabricated and tested to demonstrate the applicability of these azomethine triads in devices.
Zanatta, Rayssa Ferreira; Barreto, Bruno de Castro Ferreira; Xavier, Tathy Aparecida; Versluis, Antheunis; Soares, Carlos José
2015-02-01
This study evaluated the influence of punch and base orifice diameters on push-out test results by means of finite element analysis (FEA). FEA was performed using 3D models of the push-out test with 3 base orifice diameters (2.5, 3.0, and 3.5 mm) and 3 punch diameters (0.5, 1.0, and 1.5 mm) using MARC/MENTAT (MSC.Software). The image of a cervical slice from a root restored with a fiberglass post was used to construct the models. The mechanical properties of dentin, post, and resin cement were obtained from the literature. Bases and punches were constructed as rigid bodies. A 10-N force was applied by the punch in the center of the post in a nonlinear contact analysis. Modified von Mises stress, maximum principal stress, as well as shear and normal stress components were calculated. Both punch and base orifice sizes influenced the stress distribution of the push-out test. Bases with larger diameters and punches with smaller diameters caused higher stress in dentin and at the dentin/cement interface. FEA showed that the diameter of the orifice base had a more significant influence on the stress distribution than did the punch diameter. For this reason, both factors should be taken into account during push-out experimental tests.
NASA Astrophysics Data System (ADS)
Phanikumar, Mantha S.; McGuire, Jennifer T.
2010-08-01
Push-pull tests are a popular technique to investigate various aquifer properties and microbial reaction kinetics in situ. Most previous studies have interpreted push-pull test data using approximate analytical solutions to estimate (generally first-order) reaction rate coefficients. Though useful, these analytical solutions may not be able to describe important complexities in rate data. This paper reports the development of a multi-species, radial coordinate numerical model (PPTEST) that includes the effects of sorption, reaction lag time and arbitrary reaction order kinetics to estimate rates in the presence of mixing interfaces such as those created between injected "push" water and native aquifer water. The model has the ability to describe an arbitrary number of species and user-defined reaction rate expressions including Monod/Michelis-Menten kinetics. The FORTRAN code uses a finite-difference numerical model based on the advection-dispersion-reaction equation and was developed to describe the radial flow and transport during a push-pull test. The accuracy of the numerical solutions was assessed by comparing numerical results with analytical solutions and field data available in the literature. The model described the observed breakthrough data for tracers (chloride and iodide-131) and reactive components (sulfate and strontium-85) well and was found to be useful for testing hypotheses related to the complex set of processes operating near mixing interfaces.
The Effect and Safety of Short-Term Creatine Supplementation on Performance of Push-Ups
2007-03-01
MILITARY MEDICI’lE. 172. 3:312. 2007 The Effect and Safety of Short-Term Creatine Supplementation on Performance of Push-Ups Guarantor: LT Matthew...effects of short-term oral creatine (Cr) supplementation on exercise performance and on blood pressure and renal function were assessed. Thirty-five...before to after supplementation (p 0.437; power 0.98). The Cr group demonstrated a sig- nificant increase in serum creatinine levels (p 0.001), com
The mechanical effect of the existing cement mantle on the in-cement femoral revision.
Keeling, Parnell; Lennon, Alexander B; Kenny, Patrick J; O'Reilly, Peter; Prendergast, Patrick J
2012-08-01
Cement-in-cement revision hip arthroplasty is an increasingly popular technique to replace a loose femoral stem which retains much of the original cement mantle. However, some concern exists regarding the retention of the existing fatigued and aged cement in such cement-in-cement revisions. This study investigates whether leaving an existing fatigued and aged cement mantle degrades the mechanical performance of a cement-in-cement revision construct. Primary cement mantles were formed by cementing a polished stem into sections of tubular steel. If in the test group, the mantle underwent conditioning in saline to simulate ageing and was subject to a fatigue of 1 million cycles. If in the control group no such conditioning or fatigue was carried out. The cement-in-cement procedure was then undertaken. Both groups underwent a fatigue of 1 million cycles subsequent to the revision procedure. Application of a Mann-Whitney test on the recorded subsidence (means: 0.51, 0.46, n=10+10, P=0.496) and inducible displacement (means: 0.38, 0.36, P=0.96) revealed that there was no statistical difference between the groups. This study represents further biomechanical investigation of the mechanical behaviour of cement-in-cement revision constructs. Results suggest that pre-revision fatigue and ageing of the cement may not be deleterious to the mechanical performance of the revision construct. Thus, this study provides biomechanical evidence to back-up recent successes with this useful revision technique. Copyright © 2012 Elsevier Ltd. All rights reserved.
Evola, Francesco Roberto; Costarella, Luciano; Evola, Giuseppe; Barchitta, Martina; Agodi, Antonella; Sessa, Giuseppe
2017-01-01
AIM To evaluate the clinical and X-ray results of acetabular components and tantalum augments in prosthetic hip revisions. METHODS Fifty-eight hip prostheses with primary failure of the acetabular component were reviewed with tantalum implants. The clinical records and X-rays of these cases were retrospectively reviewed. Bone defect evaluations were based on preoperative CT scans and classified according to Paprosky criteria of Radiolucent lines and periprosthetic gaps; implant mobilization and osteolysis were evaluated by X-ray. An ad hoc database was created and statistical analyses were performed with SPSS software (IBM SPSS Statistics for Windows, version 23.0). Statistical analyses were carried out using the Student’s t test for independent and paired samples. A P value of < 0.05 was considered statistically significant and cumulative survival was calculated by the Kaplan-Meier method. RESULTS The mean follow-up was 87.6 ± 25.6 mo (range 3-120 mo). 25 cases (43.1%) were classified as minor defects, and 33 cases (56.9%) as major defects. The preoperative HHS rating improved significantly from a mean of 40.7 ± 6.1 (range: 29-53) before revision, to a mean of 85.8 ± 6.1 (range: 70-94) at the end of the follow-up (Student’s t test for paired samples: P < 0.001). Considering HHS only at the end of follow-up, no statistically significant difference was observed between patients with a major or minor defect (Student’s t test for independent samples: P > 0.05). Radiolucent lines were found in 4 implants (6.9%). Postoperative acetabular gaps were observed in 5 hips (8.6%). No signs of implant mobilization or areas of periprosthetic osteolysis were found in the x-rays at the final follow-up. Only 3 implants failed: 1 case of infection and 2 cases of instability. Defined as the end-point, cumulative survival at 10 years was 95% (for all reasons) and 100% for aseptic loosening of the acetabular component. CONCLUSION The medium-term use of prosthetic tantalum components in prosthetic hip revisions is safe and effective in a wide variety of acetabular bone defects. PMID:28808626
Evola, Francesco Roberto; Costarella, Luciano; Evola, Giuseppe; Barchitta, Martina; Agodi, Antonella; Sessa, Giuseppe
2017-07-18
To evaluate the clinical and X-ray results of acetabular components and tantalum augments in prosthetic hip revisions. Fifty-eight hip prostheses with primary failure of the acetabular component were reviewed with tantalum implants. The clinical records and X-rays of these cases were retrospectively reviewed. Bone defect evaluations were based on preoperative CT scans and classified according to Paprosky criteria of Radiolucent lines and periprosthetic gaps; implant mobilization and osteolysis were evaluated by X-ray. An ad hoc database was created and statistical analyses were performed with SPSS software (IBM SPSS Statistics for Windows, version 23.0). Statistical analyses were carried out using the Student's t test for independent and paired samples. A P value of < 0.05 was considered statistically significant and cumulative survival was calculated by the Kaplan-Meier method. The mean follow-up was 87.6 ± 25.6 mo (range 3-120 mo). 25 cases (43.1%) were classified as minor defects, and 33 cases (56.9%) as major defects. The preoperative HHS rating improved significantly from a mean of 40.7 ± 6.1 (range: 29-53) before revision, to a mean of 85.8 ± 6.1 (range: 70-94) at the end of the follow-up (Student's t test for paired samples: P < 0.001). Considering HHS only at the end of follow-up, no statistically significant difference was observed between patients with a major or minor defect (Student's t test for independent samples: P > 0.05). Radiolucent lines were found in 4 implants (6.9%). Postoperative acetabular gaps were observed in 5 hips (8.6%). No signs of implant mobilization or areas of periprosthetic osteolysis were found in the x-rays at the final follow-up. Only 3 implants failed: 1 case of infection and 2 cases of instability. Defined as the end-point, cumulative survival at 10 years was 95% (for all reasons) and 100% for aseptic loosening of the acetabular component. The medium-term use of prosthetic tantalum components in prosthetic hip revisions is safe and effective in a wide variety of acetabular bone defects.
The paper describes the Kress Indirect Dry Cooling (KIDC) process and gives results of an evaluation through baseline and demonstration emission testing. he KIDC process offers a technology that has the potential to reduce emissions from coke pushing and quenching at existing cok...
Effects of pushing techniques during the second stage of labor: A randomized controlled trial.
Koyucu, Refika Genç; Demirci, Nurdan
2017-10-01
Spontaneous pushing is a method that is used in the management of the second stage of labor and suggested to be more physiological for the mother and infant. The present study aims to evaluate the effects of pushing techniques on the mother and newborn. This randomized prospective study was performed between June 2013-March 2014 in a tertiary maternity clinic in Istanbul. 80 low risk, nulliparous cases were randomized to pushing groups. Valsalva pushing group was told to hold their breath while pushing. No visual-verbal instructions were given to spontaneous pushing group and they were encouraged to push without preventing respiration. Demographic data, second stage period, perineal laceration rates, fetal heart rate patterns, presence of meconium stained amniotic liquid, newborn APGAR scores, POP-Q examination and Q-tip test results were evaluated in these cases. The second stage of labor was significantly longer with spontaneous pushing. Decrease in Hb levels in valsalva pushing group was determined to be higher than spontaneous pushing group. An increased urethral mobility was observed in valsalva pushing group. Although the duration of the second stage of labor was longer compared to valsalva pushing technique, women were able to give birth without requiring any verbal or visual instruction, without exceeding the limit value of two hours and without affecting fetal wellness and neonatal results. Copyright © 2017. Published by Elsevier B.V.
Hansen, Scott K.; Berkowitz, Brian; Vesselinov, Velimir V.; ...
2016-12-01
Path reversibility and radial symmetry are often assumed in push-pull tracer test analysis. In reality, heterogeneous flow fields mean that both assumptions are idealizations. In this paper, to understand their impact, we perform a parametric study which quantifies the scattering effects of ambient flow, local-scale dispersion, and velocity field heterogeneity on push-pull breakthrough curves and compares them to the effects of mobile-immobile mass transfer (MIMT) processes including sorption and diffusion into secondary porosity. We identify specific circumstances in which MIMT overwhelmingly determines the breakthrough curve, which may then be considered uninformative about drift and local-scale dispersion. Assuming path reversibility, wemore » develop a continuous-time-random-walk-based interpretation framework which is flow-field-agnostic and well suited to quantifying MIMT. Adopting this perspective, we show that the radial flow assumption is often harmless: to the extent that solute paths are reversible, the breakthrough curve is uninformative about velocity field heterogeneity. Our interpretation method determines a mapping function (i.e., subordinator) from travel time in the absence of MIMT to travel time in its presence. A mathematical theory allowing this function to be directly “plugged into” an existing Laplace-domain transport model to incorporate MIMT is presented and demonstrated. Algorithms implementing the calibration are presented and applied to interpretation of data from a push-pull test performed in a heterogeneous environment. A successful four-parameter fit is obtained, of comparable fidelity to one obtained using a million-node 3-D numerical model. In conclusion, we demonstrate analytically and numerically how push-pull tests quantifying MIMT are sensitive to remobilization, but not immobilization, kinetics.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hansen, Scott K.; Berkowitz, Brian; Vesselinov, Velimir V.
Path reversibility and radial symmetry are often assumed in push-pull tracer test analysis. In reality, heterogeneous flow fields mean that both assumptions are idealizations. In this paper, to understand their impact, we perform a parametric study which quantifies the scattering effects of ambient flow, local-scale dispersion, and velocity field heterogeneity on push-pull breakthrough curves and compares them to the effects of mobile-immobile mass transfer (MIMT) processes including sorption and diffusion into secondary porosity. We identify specific circumstances in which MIMT overwhelmingly determines the breakthrough curve, which may then be considered uninformative about drift and local-scale dispersion. Assuming path reversibility, wemore » develop a continuous-time-random-walk-based interpretation framework which is flow-field-agnostic and well suited to quantifying MIMT. Adopting this perspective, we show that the radial flow assumption is often harmless: to the extent that solute paths are reversible, the breakthrough curve is uninformative about velocity field heterogeneity. Our interpretation method determines a mapping function (i.e., subordinator) from travel time in the absence of MIMT to travel time in its presence. A mathematical theory allowing this function to be directly “plugged into” an existing Laplace-domain transport model to incorporate MIMT is presented and demonstrated. Algorithms implementing the calibration are presented and applied to interpretation of data from a push-pull test performed in a heterogeneous environment. A successful four-parameter fit is obtained, of comparable fidelity to one obtained using a million-node 3-D numerical model. In conclusion, we demonstrate analytically and numerically how push-pull tests quantifying MIMT are sensitive to remobilization, but not immobilization, kinetics.« less
How should initial fit inform soft contact lens prescribing.
Boychev, Nikolay; Laughton, Deborah S; Bharwani, Gulshan; Ghuman, Hafsa; Wolffsohn, James S
2016-06-01
To investigate how initial HEMA and silicone-hydrogel (SiHy) contact lens fit on insertion, which informs prescribing decisions, reflect end of day fit. Thirty participants (aged 22.9±4.9 years) were fitted contralaterally with HEMA and SiHy contact lenses. Corneal topography and tear break-up time were assessed pre-lens wear. Centration, lag, post-blink movement during up-gaze and push-up recovery speed were recorded after 5,10,20min and 8h of contact lens wear by a digital slit-lamp biomicroscope camera, along with reported comfort. Lens fit metrics were analysed using bespoke software. Comfort and centration were similar with the HEMA and SiHy lenses (p>0.05), but comfort decreased with time (p<0.01) whereas centration remained stable (F=0.036, p=0.991). Movement-on-blink and lag were greater with the HEMA than the SiHy lens (p<0.01), but movement-on-blink decreased with time after insertion (F=22.423, p<0.001) whereas lag remained stable (F=1.967, p=0.129). Push-up recovery speed was similar with the HEMA and the SiHy lens 5-20min after insertion (p>0.05), but was slower with SiHy after 8h wear (p=0.016). Lens movement on blink and push-up recovery speed was predictive of the movement after 8h of wear after 10-20min SiHy wear, but after 5 to 20min of HEMA lens wear. A HEMA or SiHy contact lens with poor movement on blink/push-up after at least 10min after insertion should be rejected. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Bullock, Garrett S; Brookreson, Nate; Knab, Amy M; Butler, Robert J
2017-06-01
Abnormal fundamental movement patterns and upper-quarter dynamic balance are proposed mechanisms affecting athletic performance and injury risk. There are few studies investigating functional movement and closed-chain upper-extremity dynamic stability in swimmers. The purpose of this study was to determine differences in fundamental movement competency and closed-chain upper-extremity dynamic balance, using the Functional Movement Screen (FMS) and Upper-Quarter Y Balance Test (YBT-UQ), of high school (HS; n = 70) and collegiate (COL; n = 70) swimmers. Variables included the individual movement tests on the FMS and the average normalized reach (percent limb length [%LL]) for each direction, with the YBT-UQ. Statistical analysis was completed using a chi square for the independent test scores on the FMS while independent samples t-test to examine performance on the YBT-UQ (p ≤ 0.05). HS swimmers exhibited a statistically significant greater percentage of below average performance (score of 0 or 1) on the following FMS tests: lunge (HS: 22.9%, COL: 4.3%), hurdle step (HS: 31.4%, COL: 7.1%), and push-up (HS: 61.4%, COL: 31.4%). Furthermore, COL males performed worse in the lunge (male: 9%, female: 0%), whereas COL females had poorer efficiency in the push-up (male: 17.6%, female: 44%). Significant effects of competition level and sex were observed in YBT-UQ medial reach (HS: female 92.06, male 101.63; COL: female 101.3, male 101.5% LL). Individual fundamental movement patterns that involved lumbopelvic neuromuscular control differed between HS and COL swimmers. General upper-extremity dynamic balance differed between competition levels. These data may be helpful in understanding injury and performance-based normative data for participation and return to swimming.
Predicting Bobsled Pushing Ability from Various Combine Testing Events.
Tomasevicz, Curtis L; Ransone, Jack W; Bach, Christopher W
2018-03-12
The requisite combination of speed, power, and strength necessary for a bobsled push athlete coupled with the difficulty in directly measuring pushing ability makes selecting effective push crews challenging. Current practices by USA Bobsled and Skeleton (USABS) utilize field combine testing to assess and identify specifically selected performance variables in an attempt to best predict push performance abilities. Combine data consisting of 11 physical performance variables were collected from 75 subjects across two winter Olympic qualification years (2009 and 2013). These variables were sprints of 15-, 30-, and 60 m, a flying 30 m sprint, a standing broad jump, a shot toss, squat, power clean, body mass, and dry-land brake and side bobsled pushes. Discriminant Analysis (DA) in addition to Principle Component Analysis (PCA) was used to investigate two cases (Case 1: Olympians vs. non-Olympians; Case 2: National Team vs. non-National Team). Using these 11 variables, DA led to a classification rule that proved capable of identifying Olympians from non-Olympians and National Team members from non-National Team members with 9.33% and 14.67% misclassification rates, respectively. The PCA was used to find similar test variables within the combine that provided redundant or useless data. After eliminating the unnecessary variables, DA on the new combinations showed that 8 (Case 1) and 20 (Case 2) other combinations with fewer performance variables yielded misclassification rates as low as 6.67% and 13.33% respectively. Utilizing fewer performance variables can allow governing bodies in many other sports to create more appropriate combine testing that maximize accuracy, while minimizing irrelevant and redundant strategies.
Ballo, Ahmed M; Akca, Eralp; Ozen, Tuncer; Moritz, Niko; Lassila, Lippo; Vallittu, Pekka; Närhi, Timo
2014-08-01
This study aimed to evaluate the influence of implant design and bioactive glass (BAG) coating on the response of bone to fiber-reinforced composite (FRC) implants. Three different FRC implant types were manufactured for the study: non-threaded implants with a BAG coating; threaded implants with a BAG coating; and threaded implants with a grit-blasted surface. Thirty-six implants (six implants for each group per time point) were installed in the tibiae of six pigs. After an implantation period of 4 and 12 wk, the implants were retrieved and prepared for micro-computed tomography (micro-CT), push-out testing, and scanning electron microscopy analysis. Micro-CT demonstrated that the screw-threads and implant structure remained undamaged during the installation. The threaded FRC/BAG implants had the highest bone volume after 12 wk of implantation. The push-out strengths of the threaded FRC/BAG implants after 4 and 12 wk (463°N and 676°N, respectively) were significantly higher than those of the threaded FRC implants (416°N and 549°N, respectively) and the nonthreaded FRC/BAG implants (219°N and 430°N, respectively). Statistically significant correlation was found between bone volume and push-out strength values. This study showed that osseointegrated FRC implants can withstand the static loading up to failure without fracture, and that the addition of BAG significantly improves the push-out strength of FRC implants. © 2014 Eur J Oral Sci.
LOFT. Reactor arrives at containment building (TAN650), now being pushed ...
LOFT. Reactor arrives at containment building (TAN-650), now being pushed by locomotive. Camera facing northerly. Note "Hello Dolly" and "PWR MTA No. 1" (pressurized water reactor mobile test assembly) signs. Date: 1973. INEEL negative no. 73-3710 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Low-load bench press and push-up induce similar muscle hypertrophy and strength gain.
Kikuchi, Naoki; Nakazato, Koichi
2017-06-01
To investigate the effect of push-up training with a similar load of to 40% of 1- repetition maximumal (1RM) bench press on muscle hypertrophy and strength gain in men. Eighteen male participants (age, 20.2 ± 0.73 years, range: 19-22 years, height: 169.8 ± 4.4 cm, weight: 64.5 ± 4.7 kg) were randomly assigned to one of two experimental groups: bench press at 40%1RM (bench-press group, n = 9) or push-ups with position adjusted (e.g. kneeling) to the same load of bench-press 40%1RM (push-up group, n = 9), performed twice per week for 8 weeks. Muscle thickness at three sites (biceps, triceps, and pectoralis major), bench-press 1RM, maximum repetition at 40%1RM, and power output (medicine ball throw) were measured before and after the training period. Significant increases in 1RM and muscle thickness (triceps and pectoralis major) were observed in bench-press group (1RM, from 60.0 ± 12.1 kg to 65.0 ± 12.1 kg, p < 0.01; triceps, from 26.3 ± 3.7 mm to 27.8 ± 3.8 mm, p < 0.01; pectoralis major, from 17.0 ± 2.8 mm to 20.8 ± 4.8 mm, p < 0.01) and in the push-up group (1RM, from 61.1 ± 12.2 kg to 64.2 ± 12.5 kg, p < 0.01; triceps, 27.7 ± 5.7 mm to 30.4 ± 6.6 mm, p < 0.01; pectoralis major, from 17.0 ± 2.8 mm to 20.8 ± 4.8 mm, p < 0.01). Biceps thickness significantly increased only in the bench-press group (28.4 ± 3.3 mm to 31.5 ± 3.7 mm, p < 0.01). Neither power output performance nor muscle endurance capacity changed in either group. Push-up exercise with similar load to 40%1RM bench press is comparably effective for muscle hypertrophy and strength gain over an 8-week training period.
[The effect of root canal re-wetting on push-out bond strength and durability of fiber post].
Yao, Ke; Song, Jie-wen; Li, Yan
2011-02-01
To analyze the push-out bond strength of fiber post and the durability of interface between dentin and composite resin during over drying and re-wetting of root canal. Thirty-six extracted human maxillary central incisors were randomly divided into three groups: Group A for the process of over drying, Group B for re-wetting, Group C for control. All teeth were sliced into several thin discs with thickness of 1.0 mm for micro push-out test and scanning electron microscope(SEM) observation. Push-out shear strengths of fiber post immediately after bonding in group A, B and C were (5.97 ± 1.97), (7.67 ± 2.19) and (8.46 ± 2.35) MPa. Push-out strengths of fiber post two months after water storage were (2.08 ± 1.67), (2.99 ± 1.48) and (3.22 ± 1.43) MPa. There was significantly difference in push-out strength between Group A and Group B (P < 0.05). Significantly difference in push-out strength was also found between Group A and Group C. In the condition of immediate testing, there was also significantly difference between push-out strength of cervical slice and middle slice, and between cervical slice and apical slice (P < 0.05). The water storage time has significant effect on the push-out bond strength of fiber posts (P < 0.05). Inappropriate condensation air blowing operation can cause extracted teeth root canal dentin over dry. Dehydration can destroy the formation of general structure of interface between composite resin and dentin. The over dry dentin can be turned back to wetting stage by water pouring, which can help fiber-reinforced composite post regain its normal retention strength and original adhesive durability.
Push-off tests and strength evaluation of joints combining shrink fitting with bonding
NASA Astrophysics Data System (ADS)
Yoneno, Masahiro; Sawa, Toshiyuki; Shimotakahara, Ken; Motegi, Yoichi
1997-03-01
Shrink fitted joints have been used in mechanical structures. Recently, joints combining shrink fitting with anaerobic adhesives bonded between the shrink fitted surfaces have been appeared in order to increase the joint strength. In this paper, push-off test was carried out on strength of joints combining shrink fitting with bonding by material testing machine. In addition, the push-off strength of shrink fitting joints without an anaerobic adhesive was also measured. In the experiments, the effects of the shrinking allowance and the outer diameter of the rings on the joint strength are examined. The interface stress distribution in bonded shrink fitted joints subjected to a push-off load is analyzed using axisymmetrical theory of elasticity as a four-body contact problem. Using the interface stress distribution, a method for estimating joint strength is proposed. The experimental results are in a fairly good agreement with the numerical results. It is found that the strength of combination joints is greater than that of shrink fitted joints.
Uptake of cystic fibrosis testing in primary care: supply push or demand pull?
Bekker, H; Modell, M; Denniss, G; Silver, A; Mathew, C; Bobrow, M; Marteau, T
1993-01-01
OBJECTIVE--To determine the acceptability and feasibility of screening for carriers of cystic fibrosis in a primary care setting. DESIGN--Follow up study over 15 months of patients offered carrier testing by mouthwash. SETTING--A general practice in inner London. SUBJECTS--5529 patients aged 18-45 invited by various methods and combinations of methods (letter, booklet, personal approach) for testing. MAIN OUTCOME MEASURES--Uptake of screening, anxiety, and knowledge of test. RESULTS--957 (17%) invitees were screened over the 15 months. 28 carriers and no carrier couples were detected. Uptake rates were 12% (59/502 patients) among patients invited by letter and tested by appointment; 9% (47/496) among patients invited by letter, with leaflet, and tested by appointment; 4% (128/2953) among patients invited by letter six weeks before the end of the study and tested by appointment; 17% (81/471) among patients offered passive opportunistic testing; 70% (453/649) among patients offered active opportunistic testing; and 25% (22/88) among patients offered active opportunistic testing by appointment. A short term rise in anxiety among those given a positive test result had dissipated by three months. At three months about one fifth and one third of those given positive and negative results respectively did not understand their results correctly. CONCLUSION--These results suggest that the strongest variable in determining uptake of screening is the active approach by a health professional offering immediate testing. It remains to be resolved whether the high uptake rates achieved by active recruitment indicate a supply push for this new test rather than a demand from the population. PMID:8329922
Failure after reverse total shoulder arthroplasty: what is the success of component revision?
Black, Eric M; Roberts, Susanne M; Siegel, Elana; Yannopoulos, Paul; Higgins, Laurence D; Warner, Jon J P
2015-12-01
Complication rates remain high after reverse total shoulder arthroplasty (RTSA). Salvage options after implant failure have not been well defined. This study examines the role of reimplantation and revision RTSA after failed RTSA, reporting outcomes and complications of this salvage technique. Sixteen patients underwent component revision and reimplantation after a prior failed RTSA from 2004 to 2011. Indications included baseplate failure (7 patients, 43.8%), instability (6 patients, 37.5%), infection (2 patients, 12.5%), and humeral loosening (1 patient, 6.3%). The average age of the patient during revision surgery was 68.6 years. Outcomes information at follow-up was recorded, including visual analog scale score for pain, subjective shoulder value, American Shoulder and Elbow Surgeons score, and Simple Shoulder Test score, and these were compared with pre-revision values. Repeated surgeries and complications were noted. Average time to follow-up from revision was 58.9 months (minimum, 2 years; range, 24-103 months). The average postoperative visual analog scale score for pain was 1.7/10 (7.5/10 preoperatively; P < .0001), and the subjective shoulder value was 62% (17% preoperatively; P < .0001). The average postoperative American Shoulder and Elbow Surgeons score was 66.7, and the Simple Shoulder Test score was 52.6. Fourteen patients (88%) noted that they felt "better" postoperatively than before their original RTSA and would go through the procedure again if given the option. Nine patients suffered major complications (56%), and 6 of these ultimately underwent further procedures (38% of cohort). Salvage options after failure of RTSA remain limited. Component revision and reimplantation can effectively relieve pain and improve function compared with baseline values, and patient satisfaction levels are moderately high. However, complication rates and reoperation rates are significant. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Lee, Jason H.
2011-01-01
Cables are very important electrical devices that carry power and signals across multiple instruments. Any fault in a cable can easily result in a catastrophic outcome. Therefore, verifying that all cables are built to spec is a very important part of Electrical Integration Procedures. Currently, there are two methods used in lab for verifying cable connectivity. (1) Using a Break-Out Box and an ohmmeter this method is time-consuming but effective for custom cables and (2) Commercial Automated Cable Tester Boxes this method is fast, but to test custom cables often requires pre-programmed configuration files, and cables used on spacecraft are often uniquely designed for specific purposes. The idea is to develop a semi-automatic continuity tester that reduces human effort in cable testing, speeds up the electrical integration process, and ensures system safety. The JPL-Cable Tester Box is developed to check every single possible electrical connection in a cable in parallel. This system indicates connectivity through LED (light emitting diode) circuits. Users can choose to test any pin/shell (test node) with a single push of a button, and any other nodes that are shorted to the test node, even if they are in the same connector, will light up with the test node. The JPL-Cable Tester Boxes offers the following advantages: 1. Easy to use: The architecture is simple enough that it only takes 5 minutes for anyone to learn how operate the Cable Tester Box. No pre-programming and calibration are required, since this box only checks continuity. 2. Fast: The cable tester box checks all the possible electrical connections in parallel at a push of a button. If a cable normally takes half an hour to test, using the Cable Tester Box will improve the speed to as little as 60 seconds to complete. 3. Versatile: Multiple cable tester boxes can be used together. As long as all the boxes share the same electrical potential, any number of connectors can be tested together.
Use of a shorter humeral stem in revision reverse shoulder arthroplasty.
Wagner, Eric R; Statz, Joseph M; Houdek, Matthew T; Cofield, Robert H; Sánchez-Sotelo, Joaquín; Sperling, John W
2017-08-01
The purpose of this study was to examine the outcomes of revision reverse arthroplasty using short bone-preserving humeral components in revising a long-stemmed component. During a 7-year period, 39 patients who underwent revision reverse shoulder arthroplasty using the long to short humeral component technique were included. The mean age was 72 years. Prior implants used in the primary setting included anatomic (n = 26), hemiarthroplasty (n = 11), and reverse (n = 2). At a follow-up of 3 years (2-5), 5 shoulders (13%) required revision surgery, including 1 for a periprosthetic humerus fracture and 4 for glenoid component loosening. The survival free of revision for any reason and revision for humeral disease was 84% and 94%, respectively. One patient experienced a nondisplaced greater tuberosity fracture at 18 months postoperatively that healed without operative intervention. There were no dislocations or infections. Overall, patients experienced excellent overall improvements in their pain levels and shoulder motion (P < .001), with a postoperative 91% satisfaction rate as well as postoperative American Shoulder and Elbow Surgeons score of 68 and Simple Shoulder Test score of 6.7. At most recent radiographic follow-up, 1 (5%) patient had grade 3 humeral lucency. Preserving bone stock through conversion to a shorter reverse humeral stem in the revision setting is a reasonable option with good short- to intermediate-term results and low rates of humeral complications. Using the shorter stem components provides adequate stability and high rates of humeral component ingrowth. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Uzun, I; Keleş, A; Arslan, H; Güler, B; Keskin, C; Gündüz, K
2016-12-01
To evaluate the percentage volume of voids within cement layers, to determine the push-out bond strength of circular and oval fibre posts luted with different commercial resin cements in oval cross-sectional root canals, and to correlate push-out bond strength values and volume of voids of circular and oval fibre posts. Seventy-two mandibular premolars with oval-shaped root canals were selected. The specimens were divided into two main groups according to the post type (oval and circular). Groups were further divided into three subgroups (n = 24) according to resin cement type: Maxcem Elite, Rely-X Unicem and Duo-Link. The volumes of voids within the cements were analysed by micro-computed tomography (micro-CT). The bond strength was then measured using a push-out test with an Instron universal testing machine. The failure modes were evaluated. Statistical analyses were performed using a three-way anova, Tukey's post hoc, Pearson's correlation and chi-square test (P = 0.05). The push-out bond strength values were significantly affected by root canal region, post type and cement type (P < 0.001). Root canal region, post type and cement type also significantly affected void volume (P < 0.001). There was a significant interaction between post type and cement type (P < 0.001). The most frequent failure type was adhesive failure in all the groups. There was no significant correlation between the push-out bond strength and void volume (P > 0.05). Void volume did not affect push-out bond strength of oval and circular posts luted in oval canals. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Stress fracture of ulna due to excessive push-ups.
Meena, Sanjay; Rastogi, Devarshi; Solanki, Bipin; Chowdhury, Buddhadev
2014-01-01
Stress fractures are most common in the weight-bearing bones of the lower extremities and spine, but are rarely found in non-weight-bearing bones of the body. Stress fracture of the ulna is extremely rare. We report a case of complete stress fracture of ulna caused due to excessive push ups in a young athlete. Conservative management was successful in healing of fracture and returning this patient back to his previous activity level. Physician should have high index of suspicion, whenever they encounter a young athlete complaining of forearm pain.
A United States marine presenting with hemoptysis after push-ups.
Thurber, John S; Unger, Jason A; DeVries, William C
2014-04-01
We present an unusual case of right lower lobe intralobar pulmonary sequestration in a previously healthy and physical active 27-year-old U.S. Marine, who presented with new onset hemoptysis after doing push-ups. Diagnosis was obtained by chest X-ray and contrast computed tomography scan. Preoperatively the patient underwent fluoroscopy-guided embolization of the aberrant systemic artery supplying the sequestration. The segmental resection of the sequestration was then successfully performed through a muscle-sparing thoracotomy. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.
Bergoli, Cesar Dalmolin; Amaral, Marina; Boaro, Leticia Cristina; Braga, Roberto Ruggiero; Valandro, Luiz Felipe
2012-08-01
To evaluate the effect of mechanical cycling and cementation strategies on the push-out bond strength between fiber posts and root dentin and the polymerization stresses produced using three resin cements. Eighty bovine mandibular teeth were sectioned to a length of 16 mm, prepared to 12 mm, and embedded in self-curing acrylic resin. The specimens were then distributed into 8 groups (n = 10): Gr1 - Scotchbond Multi Purpose + RelyX ARC; Gr2 - Scotchbond Multi Purpose + RelyX ARC + mechanical cycling; Gr3 - AdheSE + Multilink Automix; Gr4 - AdheSE + Multilink Automix + mechanical cycling; Gr5 - phosphoric acid + RelyX U100 (self-adhesive cement); Gr6 - phosphoric acid+ RelyX U100 + mechanical cycling; Gr7 - RelyX U100; Gr8 - RelyX U100 + mechanical cycling. The values obtained from the push-out bond strength test were submitted to two-way ANOVA and Tukey's test (p = 0.05), while the values obtained from the polymerization stress test were subjected to one-way ANOVA and Tukey's test (α = 0.05). Mechanical cycling did not affect the bond strength values (p = 0.236), while cementation strategies affected the push-out bond strength (p < 0.001). Luting with RelyX U100 and Scotch Bond Multi Purpose + RelyX ARC yielded higher push-out bond strength values. The polymerization stress results were affected by the factor "cement" (p = 0.0104): the self-adhesive cement RelyX U100 exhibited the lowest values, RelyX ARC resulted in the highest values, while Multilink Automix presented values statistically similar to the other two cements. The self-adhesive cement appears to be a good alternative for luting fiber posts due to the high push-out bond strengths and lower polymerization stress values.
Production Maintenance Infrastructure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jason Gabler, David Skinner
2005-11-01
PMI is a XML framework for formulating tests of software and software environments which operate in a relatively push button manner, i.e., can be automated, and that provide results that are readily consumable/publishable via RSS. Insofar as possible the tests are carried out in manner congruent with real usage. PMI drives shell scripts via a perl program which is charge of timing, validating each test, and controlling the flow through sets of tests. Testing in PMI is built up hierarchically. A suite of tests may start by testing basic functionalities (file system is writable, compiler is found and functions, shellmore » environment behaves as expected, etc.) and work up to large more complicated activities (execution of parallel code, file transfers, etc.) At each step in this hierarchy a failure leads to generation of a text message or RSS that can be tagged as to who should be notified of the failure. There are two functionalities that PMI has been directed at. 1) regular and automated testing of multi user environments and 2) version-wise testing of new software releases prior to their deployment in a production mode.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-04
.... Description of AFUE Inflation Issues Associated with Omitting Cool-Down and Heat-Up Testing for Two-Stage and... to revise a provision concerning the insulation of the flue collector box in order to ensure the... furnaces and boilers that employ the optional procedure to skip [[Page 7683
76 FR 30363 - Agency Information Collection Request. 30-Day Public Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-25
... a onetime pilot test of a post- only survey tool to be added to the BodyWorks toolkit/resources; and, (3) conducting a full evaluation of the revised BodyWorks program, including pre, post and follow-up components as well as similar tests of the Spanish BodyWorks program. [[Page 30364
ERIC Educational Resources Information Center
Lum, Lydia
2005-01-01
Carl Washburn wondered how to push his teen-age son into studying for the SAT. After all, it's well-known that prepared students tend to score higher than those who aren't. Then Washburn realized his son's cell phone could prove a compatible study buddy. So he and others at his company developed a cell phone application that offers sample SAT…
Wireline system for multiple direct push tool usage
Bratton, Wesley L.; Farrington, Stephen P.; Shinn, II, James D.; Nolet, Darren C.
2003-11-11
A tool latching and retrieval system allows the deployment and retrieval of a variety of direct push subsurface characterization tools through an embedded rod string during a single penetration without requiring withdrawal of the string from the ground. This enables the in situ interchange of different tools, as well as the rapid retrieval of soil core samples from multiple depths during a single direct push penetration. The system includes specialized rods that make up the rod string, a tool housing which is integral to the rod string, a lock assembly, and several tools which mate to the lock assembly.
Cong, R J; Liu, J F; Jiang, Y; Dilixiati, Duolikun; Hou, X D; Zheng, L P
2018-03-01
Objective: To explore the influence of the lower extremity abnormal alignment and the joint surface, and to explore the surgical skills. Methods: Twenty-two cases of tibial plateau Schatzker Ⅵ fracture internal fixation failure revision from January 2012 to January 2017 in Department of Orthopedics, Shanghai 10(th) Hospital.One year follow-up after initial surgery to make sure of failure.Three-dimensional CT scan, radiography, infection index, gait analysis, knee joint ROM, femur tibia angle, tibial plateau tibial shaft angle and posterior slope if tibial plateau were observed. The medial approach and bi-planer osteotoma were used.Autogenous iliac bone graft, postoperative fast recovery channel were used.Follow-up point included preoperative and postoperative 7 days, 6 weeks, 3 months, and 6 months.Obvervational index included double lower limbs radiography, knee society score(KSS), complications such as infection, skin necrosis, joint main passive activity, double lower limbs alignment the last follow-up SF-36 scale.Rate was compared by χ(2) test, measurement data using paired sample t test.Correlation was analyzed by Pearson correlation regression testing. Results: Twenty-two patients received follow-up.KSS, more than 21 cases were benign, with good gait.One case was poor, with claudication gait.Not skin necrosis, no deep infection cases, 1 case get blisters 2 days postoperatively, and disappear after 5 days with detumescence and cold therapy.Whether restoring force line affect the KSS significantly(χ(2)=22.000, P =0.000). Knee joint ROM, SF-36 score, KSS and lower limb alignment were improved significantly. In different individual the articular surface and anatomical angle recovered greatly but the posterior slope angle was quite difference which has no correlation with KSS and SF-36 scale( P >0.01). Conclusions: Revision of Schatzker type Ⅵ tibial plateau fracture failure should focus on the recovery of lower limb alignment.moderate overcorrect bone cutting and joint surface height can bring benefits to the postoperative knee function.Revision surgery patients have greater psychological pressure, more early psychological intervention is necessary.
Influence of imbalance on distortion in optical push-pull frontends
NASA Astrophysics Data System (ADS)
Hagensen, Morten
1995-04-01
The influence of imbalance on second-order inter-modulation distortion (IMD2) in optical push-pull frontends for Subcarrier Multiplex CATV applications is investigated theoretically and experimentally. The investigation focuses on imbalance introduced in either the photodiode, the push-pull amplifier, or the output balun, and expressions describing the overall IMD2 cancellation efficiency are derived. The developed theory is used to predict the IMD2 cancellation behavior of an optical push-pull fronted. Commercially available PIN photodiodes for CATV purposes and ferrite core transformers are characterised for phase and amplitude balance up to 1 GHz. The overall IMD2 cancellation efficiency of an optical push-pull frontend based on the best of these devices is calculated. The theory is finally verified experimentally with an optical push-pull frontend designed with the characterised photodiode and transformer. The improvement in IMD2 suppression obtained with the push-pull structure relative to a single-ended structure is in average 29 dB across the band from 47-862 MHz. The total IMD2 suppression obtained for the frontend is between 60 dBc and 79 dBc at an average optical input power of 1 mW and with an optical modulation index (OMI) of 35% per carrier in a two-tone setup.
NASA Astrophysics Data System (ADS)
Bourke, Sarah A.; Hermann, Kristian J.; Hendry, M. Jim
2017-11-01
Elevated groundwater salinity associated with produced water, leaching from landfills or secondary salinity can degrade arable soils and potable water resources. Direct-push electrical conductivity (EC) profiling enables rapid, relatively inexpensive, high-resolution in-situ measurements of subsurface salinity, without requiring core collection or installation of groundwater wells. However, because the direct-push tool measures the bulk EC of both solid and liquid phases (ECa), incorporation of ECa data into regional or historical groundwater data sets requires the prediction of pore water EC (ECw) or chloride (Cl-) concentrations from measured ECa. Statistical linear regression and physically based models for predicting ECw and Cl- from ECa profiles were tested on a brine plume in central Saskatchewan, Canada. A linear relationship between ECa/ECw and porosity was more accurate for predicting ECw and Cl- concentrations than a power-law relationship (Archie's Law). Despite clay contents of up to 96%, the addition of terms to account for electrical conductance in the solid phase did not improve model predictions. In the absence of porosity data, statistical linear regression models adequately predicted ECw and Cl- concentrations from direct-push ECa profiles (ECw = 5.48 ECa + 0.78, R 2 = 0.87; Cl- = 1,978 ECa - 1,398, R 2 = 0.73). These statistical models can be used to predict ECw in the absence of lithologic data and will be particularly useful for initial site assessments. The more accurate linear physically based model can be used to predict ECw and Cl- as porosity data become available and the site-specific ECw-Cl- relationship is determined.
Spielman, Bethany
2009-01-01
In re Matter of Daniel Thomas Christy authorized post mortem gamete retrieval under the most recent revision of the Uniform Anatomical Gift Act. This article recommends that the National Conference of Commissioners on Uniform State Laws explicitly address the issue of post mortem gamete retrieval for reproductive purposes; that legislators specify whether their states will follow the Christy ruling; and that ethics committees and consultants prepare for the questions about human identity and self determination that post mortem gamete retrieval raises.
Relationship Between Body Fat and Physical Fitness in Army ROTC Cadets.
Steed, Carly L; Krull, Benjamin R; Morgan, Amy L; Tucker, Robin M; Ludy, Mary-Jon
2016-09-01
The Army Physical Fitness Test (APFT), including timed push-ups, sit-ups, and run, assesses physical performance for the Army. Percent body fat is estimated using height and circumference measurements. The objectives of the study were to (a) compare the accuracy of height and circumference measurements to other, more accepted, body fat assessment methods and (b) determine the relationships between body composition and APFT results. Participants included Reserve Officer Training Corps (ROTC) cadets (n = 11 males, 2 females, 21.6 ± 3.5 years) from a midwestern university). At one visit, percent body fat was assessed using height and circumference measurements, air-displacement plethysmography, and bioelectrical impedance analysis. APFT results were provided by the ROTC director. All assessment methods for percent body fat were strongly associated (r ≥ 0.7, p < 0.01), implying that height and circumference measurement is a practical tool to estimate percent body fat of ROTC cadets. Total APFT score was not associated with any body fat assessment method. Push-up number was negatively associated with percent body fat by all assessment methods (r ≥ -0.8, p = 0.001), although run time was positively associated (r ≥ 0.6, p < 0.05). This suggests that percent body fat may be an important variable in determining or improving cardiovascular and muscular endurance, but not APFT performance. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Altieri, Maria S; Yang, Jie; Telem, Dana A; Meng, Ziqi; Frenkel, Catherine; Halbert, Caitlin; Talamini, Mark; Pryor, Aurora D
2016-05-01
We sought to determine the rate of revision and explant of the laparoscopic adjustable gastric banding (LAGB) over a ten-year period in the state of New York. Following IRB approval, the SPARCS administrative database was used to identify LAGB placement from 2004 to 2010. We tracked patients who underwent band placement with subsequent removal/revision, followed by conversion to either Roux-en-Y gastric bypass (RYBG) or sleeve gastrectomy (SG) between 2004 and 2013. McNemar test and Chi-square test were used to compare complications between primary procedure and subsequent revision and to compare complication rates and mortality rates, respectively. Log-rank test was used to assess patient characteristics and comorbidities. p < 0.05 was considered significant. During a 7-year period, there were 19,221 records of LAGB placements and 6567 records of revisions or removal. We were able to follow up 3158 (16.43 %) who subsequently underwent a band removal or revision over the course of this period. An additional 3606 patients had no records in the state of New York following the procedure, thus making the rate of revision 20.22 %. Initial revision procedures were coded as band removal in 32.77 % (n = 1035), band revision in 30.53 % (n = 964), band removal and replacement in 19.09 % (n = 603), removal and conversion to SG in 5.64 % (n = 178), or removal and conversion to RYGB in 11.97 % (n = 378). From the 3158 patients, 2515 (79.64 %) required only one revision. Six hundred and forty-three patients underwent two or more revisions. Thirty-one out of 3158 (0.0098 %) patients had complications at their initial operation, but 919 (29.1 %) had complications during revision (p < 0.0001). Over a 7-year period, at least 20.22 % of LAGB required removal or revision. Based on all case numbers, total revision rate may be as high as 34.2 %. Although the band is believed to be a reversible procedure, revisional procedures are significantly more morbid than the initial procedure.
Merolla, Giovanni; Wagner, Eric; Sperling, John W; Paladini, Paolo; Fabbri, Elisabetta; Porcellini, Giuseppe
2018-01-01
There remains a paucity of studies examining the conversion of failed hemiarthroplasty (HA) to reverse total shoulder arthroplasty (RTSA). Therefore, the purpose of this study was to examine a large series of revision HA to RTSA. A population of 157 patients who underwent conversion of a failed HA to a revision RTSA from 2006 through 2014 were included. The mean follow-up was 49 months (range, 24-121 months). The indications for revision surgery included instability with rotator cuff insufficiency (n = 127) and glenoid wear (n = 30); instability and glenoid wear were associated in 38 cases. Eight patients with infection underwent 2-stage reimplantation. Patients experienced significant improvements in their preoperative to postoperative pain and shoulder range of motion (P < .0001), with median American Shoulder and Elbow Surgeons and Simple Shoulder Test scores of 60 and 6 points, respectively. There were 11 (7%) repeated revision surgeries, secondary to glenoid component loosening (n = 3), instability (n = 3), humeral component disassembly (n = 2), humeral stem loosening (n = 1), and infection (n = 2). Implant survivorship was 95.5% at 2 years and 93.3% at 5 years. There were 4 reoperations including axillary nerve neurolysis (n = 2), heterotopic ossification removal (n = 1), and hardware removal for rupture of the metal cerclage for an acromial fracture (n = 1). At final follow-up, there were 5 "at-risk" glenoid components. Patients experience satisfactory pain relief and recovery of reasonable shoulder function after revision RTSA from a failed HA. There was a relatively low revision rate, with glenoid loosening and instability being the most common causes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Analysis of Stress in Steel and Concrete in Cfst Push-Out Test Samples
NASA Astrophysics Data System (ADS)
Grzeszykowski, Bartosz; Szadkowska, Magdalena; Szmigiera, Elżbieta
2017-09-01
The paper presents the analysis of stress in steel and concrete in CFST composite elements subjected to push-out tests. Two analytical models of stress distribution are presented. The bond at the interface between steel and concrete in the initial phase of the push-out test is provided by the adhesion. Until the force reach a certain value, the slip between both materials does not occur or it is negligibly small, what ensures full composite action of the specimen. In the first analytical model the full bond between both materials was assumed. This model allows to estimate value of the force for which the local loss of adhesion in given cross section begins. In the second model it was assumed that the bond stress distribution is constant along the shear transfer length of the specimen. Based on that the formulas for triangle distribution of stress in steel and concrete for the maximum push-out force were derived and compared with the experimental results. Both models can be used to better understand the mechanisms of interaction between steel and concrete in composite steel-concrete columns.
Stöggl, Thomas; Müller, Erich; Lindinger, Stefan
2008-09-01
The aims of the study were to: (1) adapt the "double-push" technique from inline skating to cross-country skiing; (2) compare this new skiing technique with the conventional skate skiing cross-country technique; and (3) test the hypothesis that the double-push technique improves skiing speed in a short sprint. 13 elite skiers performed maximum-speed sprints over 100 m using the double-push skate skiing technique and using the conventional "V2" skate skiing technique. Pole and plantar forces, knee angle, cycle characteristics, and electromyography of nine lower body muscles were analysed. We found that the double-push technique could be successfully transferred to cross-country skiing, and that this new technique is faster than the conventional skate skiing technique. The double-push technique was 2.9 +/- 2.2% faster (P < 0.001), which corresponds to a time advantage of 0.41 +/- 0.31 s over 100 m. The double-push technique had a longer cycle length and a lower cycle rate, and it was characterized by higher muscle activity, higher knee extension amplitudes and velocities, and higher peak foot forces, especially in the first phase of the push-off. Also, the foot was more loaded laterally in the double-push technique than in the conventional skate skiing technique.
NASA Astrophysics Data System (ADS)
Gueting, Nils; Vienken, Thomas; Klotzsche, Anja; van der Kruk, Jan; Vanderborght, Jan; Caers, Jef; Vereecken, Harry; Englert, Andreas
2017-01-01
Limited knowledge about the spatial distribution of aquifer properties typically constrains our ability to predict subsurface flow and transport. Here we investigate the value of using high resolution full-waveform inversion of cross-borehole ground penetrating radar (GPR) data for aquifer characterization. By stitching together GPR tomograms from multiple adjacent crosshole planes, we are able to image, with a decimeter scale resolution, the dielectric permittivity and electrical conductivity of an alluvial aquifer along cross sections of 50 m length and 10 m depth. A logistic regression model is employed to predict the spatial distribution of lithological facies on the basis of the GPR results. Vertical profiles of porosity and hydraulic conductivity from direct-push, flowmeter and grain size data suggest that the GPR predicted facies classification is meaningful with regard to porosity and hydraulic conductivity, even though the distributions of individual facies show some overlap and the absolute hydraulic conductivities from the different methods (direct-push, flowmeter, grain size) differ up to approximately one order of magnitude. Comparison of the GPR predicted facies architecture with tracer test data suggests that the plume splitting observed in a tracer experiment was caused by a hydraulically low-conductive sand layer with a thickness of only a few decimeters. Because this sand layer is identified by GPR full-waveform inversion but not by conventional GPR ray-based inversion we conclude that the improvement in spatial resolution due to full-waveform inversion is crucial to detect small-scale aquifer structures that are highly relevant for solute transport.
Arterial cord blood lactate at birth correlates with duration of pushing efforts.
Dessolle, Lionel; Lebrec, Jeremie; Daraï, Emile
2010-01-01
To evaluate the impact of the duration of pushing efforts on arterial cord blood lactate values. This was a prospective observational study of 124 consecutive normal vaginal deliveries in a tertiary teaching hospital. Arterial cord blood lactate was determined immediately at birth with a test strip method. Univariate and multivariate analyses were performed to check for clinical determinants of lactate levels. The main measure was lactate according to the duration of pushing efforts. Arterial cord lactates increased significantly and were strongly correlated with the duration of pushing efforts, independent of gestational age and birthweight. Women pushing for more than 20 min had higher arterial cord blood lactates (4.9 +/- 1.4 vs. 3.3 +/- 1.16 mM, respectively) and a higher rate of lactates >6 mM (18 vs. 3%) than those pushing for less than 20 min. At normal delivery, arterial cord blood lactates increase significantly with the duration of pushing efforts. Pushing for more than 20 min is associated with an increased risk of metabolic acidosis in the neonate. Further studies are required to evaluate the clinical significance of these observations. 2009 S. Karger AG, Basel.
Cousijn, Janna; Goudriaan, Anna E; Wiers, Reinout W
2011-01-01
Aims Repeated drug exposure can lead to an approach-bias, i.e. the relatively automatically triggered tendencies to approach rather that avoid drug-related stimuli. Our main aim was to study this approach-bias in heavy cannabis users with the newly developed cannabis Approach Avoidance Task (cannabis-AAT) and to investigate the predictive relationship between an approach-bias for cannabis-related materials and levels of cannabis use, craving, and the course of cannabis use. Design, settings and participants Cross-sectional assessment and six-month follow-up in 32 heavy cannabis users and 39 non-using controls. Measurements Approach and avoidance action-tendencies towards cannabis and neutral images were assessed with the cannabis AAT. During the AAT, participants pulled or pushed a joystick in response to image orientation. To generate additional sense of approach or avoidance, pulling the joystick increased picture size while pushing decreased it. Craving was measured pre- and post-test with the multi-factorial Marijuana Craving Questionnaire (MCQ). Cannabis use frequencies and levels of dependence were measured at baseline and after a six-month follow-up. Findings Heavy cannabis users demonstrated an approach-bias for cannabis images, as compared to controls. The approach-bias predicted changes in cannabis use at six-month follow-up. The pre-test MCQ emotionality and expectancy factor were associated negatively with the approach-bias. No effects were found on levels of cannabis dependence. Conclusions Heavy cannabis users with a strong approach-bias for cannabis are more likely to increase their cannabis use. This approach-bias could be used as a predictor of the course of cannabis use to identify individuals at risk from increasing cannabis use. PMID:21518067
Haney, Kanathy; Messiah, Sarah E; Arheart, Kristopher L; Hanson, Eric; Diego, Allison; Kardys, Jack; Kirwin, Kevin; Nottage, Renae; Ramirez, Shawn; Somarriba, Gabriel; Binhack, Lucy
2014-07-01
Children with disabilities are more likely to be overweight or obese and less likely to engage in physical activities versus their peers without disabilities. The effect of a structured afterschool program housed in a large county parks system on several obesity-related health outcomes among children with disabilities was examined. Children/adolescents with a developmental and/or intellectual disability ages 6-22 (N = 52, mean age 13.7 years) who participated in an afterschool (either 2010-2011 or 2011-2012 school year) health and wellness program called Fit-2-Play™ were assessed. Pre-post comparison of outcome variables (mean height, weight, waist/hip/midarm circumference, fitness tests, and a 9-item health and wellness knowledge assessment) via general linear mixed models analysis was conducted to evaluate the effectiveness of the program for normal and overweight/obese participants. Normal weight participants significantly improved pre-post mean number of push-ups (9.69-14.23, p = 0.01) and laps on the PACER test (8.54-11.38, p < 0.01) and the overweight/obese group significantly improved the number of sit ups (7.51-9.84, p < 0.01) and push ups (4.77-9.89, p < 0.001). Pre-post mean health and wellness knowledge composite scores significantly improved for all participants (p < 0.01). Parks-based afterschool programs can be effective community resources for instilling physical health in both normal weight and overweight/obese children with disabilities. More studies are needed to ascertain whether community-based afterschool health and wellness programs can be implemented and sustained across this population. Copyright © 2014 Elsevier Inc. All rights reserved.
A push-pull system to reduce house entry of malaria mosquitoes
2014-01-01
Background Mosquitoes are the dominant vectors of pathogens that cause infectious diseases such as malaria, dengue, yellow fever and filariasis. Current vector control strategies often rely on the use of pyrethroids against which mosquitoes are increasingly developing resistance. Here, a push-pull system is presented, that operates by the simultaneous use of repellent and attractive volatile odorants. Method/Results Experiments were carried out in a semi-field set-up: a traditional house which was constructed inside a screenhouse. The release of different repellent compounds, para-menthane-3,8-diol (PMD), catnip oil e.o. and delta-undecalactone, from the four corners of the house resulted in significant reductions of 45% to 81.5% in house entry of host-seeking malaria mosquitoes. The highest reductions in house entry (up to 95.5%), were achieved by simultaneously repelling mosquitoes from the house (push) and removing them from the experimental set-up using attractant-baited traps (pull). Conclusions The outcome of this study suggests that a push-pull system based on attractive and repellent volatiles may successfully be employed to target mosquito vectors of human disease. Reductions in house entry of malaria vectors, of the magnitude that was achieved in these experiments, would likely affect malaria transmission. The repellents used are non-toxic and can be used safely in a human environment. Delta-undecalactone is a novel repellent that showed higher effectiveness than the established repellent PMD. These results encourage further development of the system for practical implementation in the field. PMID:24674451
NASA Technical Reports Server (NTRS)
Eldridge, J. I.; Honecy, F. S.
1990-01-01
AES depth profiling and a fiber push-out test for interfacial shear-strength determination have been used to ascertain the mechanical/chemical properties of the fiber/matrix interface in SiC-reinforced reaction-bonded Si3N4, with attention to the weak point where interfacial failure occurs. In the cases of both composite fracture and fiber push-outs, the interfacial failure occurred either between the two C-rich coatings that are present on the double-coated SiC fibers, or between the inner C-rich coating and the SiC fiber. Interface failure occurs at points of very abrupt concentration changes.
Malcolm, Philippe; Quesada, Roberto E; Caputo, Joshua M; Collins, Steven H
2015-02-22
Robotic ankle-foot prostheses that provide net positive push-off work can reduce the metabolic rate of walking for individuals with amputation, but benefits might be sensitive to push-off timing. Simple walking models suggest that preemptive push-off reduces center-of-mass work, possibly reducing metabolic rate. Studies with bilateral exoskeletons have found that push-off beginning before leading leg contact minimizes metabolic rate, but timing was not varied independently from push-off work, and the effects of push-off timing on biomechanics were not measured. Most lower-limb amputations are unilateral, which could also affect optimal timing. The goal of this study was to vary the timing of positive prosthesis push-off work in isolation and measure the effects on energetics, mechanics and muscle activity. We tested 10 able-bodied participants walking on a treadmill at 1.25 m · s(-1). Participants wore a tethered ankle-foot prosthesis emulator on one leg using a rigid boot adapter. We programmed the prosthesis to apply torque bursts that began between 46% and 56% of stride in different conditions. We iteratively adjusted torque magnitude to maintain constant net positive push-off work. When push-off began at or after leading leg contact, metabolic rate was about 10% lower than in a condition with Spring-like prosthesis behavior. When push-off began before leading leg contact, metabolic rate was not different from the Spring-like condition. Early push-off led to increased prosthesis-side vastus medialis and biceps femoris activity during push-off and increased variability in step length and prosthesis loading during push-off. Prosthesis push-off timing had no influence on intact-side leg center-of-mass collision work. Prosthesis push-off timing, isolated from push-off work, strongly affected metabolic rate, with optimal timing at or after intact-side heel contact. Increased thigh muscle activation and increased human variability appear to have caused the lack of reduction in metabolic rate when push-off was provided too early. Optimal timing with respect to opposite heel contact was not different from normal walking, but the trends in metabolic rate and center-of-mass mechanics were not consistent with simple model predictions. Optimal push-off timing should also be characterized for individuals with amputation, since meaningful benefits might be realized with improved timing.
Factors affecting minimum push and pull forces of manual carts.
Al-Eisawi, K W; Kerk, C J; Congleton, J J; Amendola, A A; Jenkins, O C; Gaines, W
1999-06-01
The minimum forces needed to manually push or pull a 4-wheel cart of differing weights with similar wheel sizes from a stationary state were measured on four floor materials under different conditions of wheel width, diameter, and orientation. Cart load was increased from 0 to 181.4 kg in increments of 36.3 kg. The floor materials were smooth concrete, tile, asphalt, and industrial carpet. Two wheel widths were tested: 25 and 38 mm. Wheel diameters were 51, 102, and 153 mm. Wheel orientation was tested at four levels: F0R0 (all four wheels aligned in the forward direction), F0R90 (the two front wheels, the wheels furthest from the cart handle, aligned in the forward direction and the two rear wheels, the wheels closest to the cart handle, aligned at 90 degrees to the forward direction), F90R0 (the two front wheels aligned at 90 degrees to the forward direction and the two rear wheels aligned in the forward direction), and F90R90 (all four wheels aligned at 90 degrees to the forward direction). Wheel width did not have a significant effect on the minimum push/pull forces. The minimum push/pull forces were linearly proportional to cart weight, and inversely proportional to wheel diameter. The coefficients of rolling friction were estimated as 2.2, 2.4, 3.3, and 4.5 mm for hard rubber wheels rolling on smooth concrete, tile, asphalt, and industrial carpet floors, respectively. The effect of wheel orientation was not consistent over the tested conditions, but, in general, the smallest minimum push/pull forces were measured with all four wheels aligned in the forward direction, whereas the largest minimum push/pull forces were measured when all four wheels were aligned at 90 degrees to the forward direction. There was no significant difference between the push and pull forces when all four wheels were aligned in the forward direction.
Ashnagar, Zinat; Shadmehr, Azadeh; Hadian, Mohammadreza; Talebian, Saeed; Jalaei, Shohreh
2016-08-10
Whole Body Vibration (WBV) has been reported to change neuromuscular activity which indirectly assessed by electromyography (EMG). Although researches regarding the influence of WBV on EMG activity of the upper extremity muscles are in their infancy, contradictory findings have been reported as a result of dissimilar protocols. The purpose of this study was to investigate the effects of WBV on electromyography (EMG) activity of upper extremity muscles in static modified push up position. Forty recreationally active females were randomly assigned in WBV and control groups. Participants in WBV group received 5 sets of 30 seconds vibration at 5 mm (peak to peak) and 30 Hz by using vibratory platform. No vibration stimulus was used in the control group. Surface EMG was recorded from Upper Trapezius (UT), Serratus Anterior (SA), Biceps Brachii (BB) and Triceps Brachii (TB) muscles before, during and after the vibration protocol while the subjects maintained the static modified push up position. EMG signals were expressed as root mean square (EMGrms) and normalized by maximum voluntary exertion (MVE). EMGrms activity of the studied muscles increased significantly during the vibration protocol in the WBV group comparing to the control group (P ≤ 0.05). The results indicated that vibration stimulus transmitting via hands increased muscle activity of UT, SA, BB and TB muscles by an average of 206%, 60%, 106% and 120%, respectively, comparing to pre vibration values. These findings suggest that short exposure to the WBV could increase the EMGrms activity of the upper extremity muscles in the static modified push-up position. However, more sessions of WBV application require for a proper judgment.
Marcolin, Giuseppe; Petrone, Nicola; Moro, Tatiana; Battaglia, Giuseppe; Bianco, Antonino; Paoli, Antonio
2015-11-01
The push-up is a widely used exercise for upper limb strengthening that can be performed with many variants. A comprehensive analysis of muscle activation during the ascendant phase (AP) and descendant phase (DP) in different variants could be useful for trainers and rehabilitators. To obtain information on the effect of different push-up variants on the electromyography (EMG) of a large sample of upper limb muscles and to investigate the role of the trunk and abdomen muscles during the AP and DP. Cross-sectional study. University laboratory. Eight healthy, young volunteers without a history of upper extremity or spine injury. Participants performed a set of 10 repetitions for each push-up variant: standard, wide, narrow, forward (FP), and backward (BP). Surface EMG of 12 selected muscles and kinematics data were synchronously recorded to describe the AP and DP. Mean EMG activity of the following muscles was analyzed: serratus anterior, deltoideus anterior, erector spinae, latissimus dorsi, rectus abdominis, triceps brachii caput longus, triceps brachii caput lateralis, obliquus externus abdominis, pectoralis major sternal head, pectoralis major clavicular head, trapezius transversalis, and biceps brachii. The triceps brachii and pectoralis major exhibited greater activation during the narrow-base variant. The highest activation of abdomen and back muscles was recorded for the FP and BP variants. The DP demonstrated the least electrical activity across all muscles, with less marked differences for the abdominal and erector spinae muscles because of their role as stabilizers. Based on these findings, we suggest the narrow-base variant to emphasize triceps and pectoralis activity and the BP variant for total upper body strength conditioning. The FP and BP variants should be implemented carefully in participants with low back pain because of the greater activation of abdominal and back muscles.
MAHDI, Alaa Abdul; BOLAÑOS-CARMONA, Victoria; GONZALEZ-LOPEZ, Santiago
2013-01-01
Objectives To investigate the bond strength and seal ability produced by AH Plus/gutta-percha, EndoREZ and RealSeal systems to root canal dentin. Material and Methods Sixty extracted single-root human teeth, instrumented manually to size 40, were divided into three groups (n=20) according to the sealer used; G1: AH Plus, G2: EndoREZ, and G3: RealSeal sealers. After filling using the lateral condensation technique, each sealer group was randomly divided into two subgroups according to the tests applied (n=10 for µPush-out test and n=10 for fluid filtration test). A fluid filtration method was used for quantitative evaluation of apical leakage. Four 1-mm-thick slices (cervical and medium level) were obtained from each root sample and a µPush-out test was performed. Failure modes were examined under microscopy at 40x, and a one-way ANOVA was applied to analyze the permeability. Non-parametrical statistics for related (Friedman's and Wilcoxon's rank tests) or unrelated samples (Kruskal-Wallis' and Mann-Whitney's tests) allowed for comparisons of µPush-out strength values among materials at the different levels. Statistical significance was accepted for p values <.05. Results There are no significant differences among fluid filtration of the three sealers. The sealer/core material does not significantly influence the µPush-out bond strength values (F=2.49; p=0.10), although statistically significant differences were detected with regard to root level (Chi2=23.93; p<0.001). AH Plus and RealSeal obtained higher bond strength to intraradicular dentin in the medium root slices. Conclusions There are no significant differences between the permeability and global µPush-out bond strength to root canal dentin achieved by AH Plus/gutta-percha, EndoREZ and RealSeal systems. PMID:24037078
Range of Motion of the Ankle According to Pushing Force, Gender and Knee Position.
Cho, Kang Hee; Jeon, Yumi; Lee, Hyunkeun
2016-04-01
To investigate the difference of range of motion (ROM) of ankle according to pushing force, gender and knee position. One hundred and twenty-eight healthy adults (55 men, 73 women) between the ages of 20 and 51, were included in the study. One examiner measured the passive range of motion (PROM) of ankle by Dualer IQ Inclinometers and Commander Muscle Testing. ROM of ankle dorsiflexion (DF) and plantarflexion (PF) according to change of pushing force and knee position were measured at prone position. There was significant correlation between ROM and pushing force, the more pushing force leads the more ROM at ankle DF and ankle PF. Knee flexion of 90° position showed low PF angle and high ankle DF angle, as compared to the at neutral position of knee joint. ROM of ankle DF for female was greater than for male, with no significant difference. ROM of ankle PF for female was greater than male regardless of the pushing force. To our knowledge, this is the first study to assess the relationship between pushing force and ROM of ankle joint. There was significant correlation between ROM of ankle and pushing force. ROM of ankle PF for female estimated greater than male regardless of the pushing force and the number of measurement. The ROM of the ankle is measured differently according to the knee joint position. Pushing force, gender and knee joint position are required to be considered when measuring the ROM of ankle joint.
Prosthetic ankle push-off work reduces metabolic rate but not collision work in non-amputee walking.
Caputo, Joshua M; Collins, Steven H
2014-12-03
Individuals with unilateral below-knee amputation expend more energy than non-amputees during walking and exhibit reduced push-off work and increased hip work in the affected limb. Simple dynamic models of walking suggest a possible solution, predicting that increasing prosthetic ankle push-off should decrease leading limb collision, thereby reducing overall energy requirements. We conducted a rigorous experimental test of this idea wherein ankle-foot prosthesis push-off work was incrementally varied in isolation from one-half to two-times normal levels while subjects with simulated amputation walked on a treadmill at 1.25 m · s(-1). Increased prosthesis push-off significantly reduced metabolic energy expenditure, with a 14% reduction at maximum prosthesis work. In contrast to model predictions, however, collision losses were unchanged, while hip work during swing initiation was decreased. This suggests that powered ankle push-off reduces walking effort primarily through other mechanisms, such as assisting leg swing, which would be better understood using more complete neuromuscular models.
Prosthetic ankle push-off work reduces metabolic rate but not collision work in non-amputee walking
NASA Astrophysics Data System (ADS)
Caputo, Joshua M.; Collins, Steven H.
2014-12-01
Individuals with unilateral below-knee amputation expend more energy than non-amputees during walking and exhibit reduced push-off work and increased hip work in the affected limb. Simple dynamic models of walking suggest a possible solution, predicting that increasing prosthetic ankle push-off should decrease leading limb collision, thereby reducing overall energy requirements. We conducted a rigorous experimental test of this idea wherein ankle-foot prosthesis push-off work was incrementally varied in isolation from one-half to two-times normal levels while subjects with simulated amputation walked on a treadmill at 1.25 m.s-1. Increased prosthesis push-off significantly reduced metabolic energy expenditure, with a 14% reduction at maximum prosthesis work. In contrast to model predictions, however, collision losses were unchanged, while hip work during swing initiation was decreased. This suggests that powered ankle push-off reduces walking effort primarily through other mechanisms, such as assisting leg swing, which would be better understood using more complete neuromuscular models.
Prosthetic ankle push-off work reduces metabolic rate but not collision work in non-amputee walking
Caputo, Joshua M.; Collins, Steven H.
2014-01-01
Individuals with unilateral below-knee amputation expend more energy than non-amputees during walking and exhibit reduced push-off work and increased hip work in the affected limb. Simple dynamic models of walking suggest a possible solution, predicting that increasing prosthetic ankle push-off should decrease leading limb collision, thereby reducing overall energy requirements. We conducted a rigorous experimental test of this idea wherein ankle-foot prosthesis push-off work was incrementally varied in isolation from one-half to two-times normal levels while subjects with simulated amputation walked on a treadmill at 1.25 m·s−1. Increased prosthesis push-off significantly reduced metabolic energy expenditure, with a 14% reduction at maximum prosthesis work. In contrast to model predictions, however, collision losses were unchanged, while hip work during swing initiation was decreased. This suggests that powered ankle push-off reduces walking effort primarily through other mechanisms, such as assisting leg swing, which would be better understood using more complete neuromuscular models. PMID:25467389
Spontaneous pushing to prevent postpartum urinary incontinence: a randomized, controlled trial
Miller, Janis M.; Guo, Ying; Ashton-Miller, James A.; DeLancey, John O. L.; Sampselle, Carolyn M.
2014-01-01
Introduction and hypothesis The risk for urinary incontinence can be 2.6-fold greater in women after pregnancy and childbirth compared with their never-pregnant counterparts, with the incidence increasing with parity. We tested the hypothesis that the incidence of de novo postpartum urinary incontinence in primiparous women is reduced with the use of spontaneous pushing alone or in combination with perineal massage compared with women who experienced traditional directed pushing for second-stage management. Methods This was a prospective clinical trial enrolling and randomizing 249 women into a four-group design: (1) routine care with coached or directed pushing, (2) spontaneous self-directed pushing, (3) prenatal perineal massage initiated in the third trimester, and (4) the combination of spontaneous pushing plus perineal massage. Self-report of incontinence was assessed using analysis of variance (ANOVA) and covariance (ANCOVA) models in 145 remaining women at 12 months postpartum using the Leakage Index, which is sensitive to minor leakage. Results No statistical difference in the incidence of de novo postpartum incontinence was found based on method of pushing (spontaneous/directed) (P value=0.57) or in combination with prenatal perineal massage (P value=0.57). Fidelity to pushing treatment of type was assessed and between-groups crossover detected. Conclusions Spontaneous pushing did not reduce the incidence of postpartum incontinence experienced by women 1 year after their first birth due to high cross-over between randomization groups. PMID:22829349
Spontaneous pushing to prevent postpartum urinary incontinence: a randomized, controlled trial.
Low, Lisa Kane; Miller, Janis M; Guo, Ying; Ashton-Miller, James A; DeLancey, John O L; Sampselle, Carolyn M
2013-03-01
The risk for urinary incontinence can be 2.6-fold greater in women after pregnancy and childbirth compared with their never-pregnant counterparts, with the incidence increasing with parity. We tested the hypothesis that the incidence of de novo postpartum urinary incontinence in primiparous women is reduced with the use of spontaneous pushing alone or in combination with perineal massage compared with women who experienced traditional directed pushing for second-stage management. This was a prospective clinical trial enrolling and randomizing 249 women into a four-group design: (1) routine care with coached or directed pushing, (2) spontaneous self-directed pushing, (3) prenatal perineal massage initiated in the third trimester, and (4) the combination of spontaneous pushing plus perineal massage. Self-report of incontinence was assessed using analysis of variance (ANOVA) and covariance (ANCOVA) models in 145 remaining women at 12 months postpartum using the Leakage Index, which is sensitive to minor leakage. No statistical difference in the incidence of de novo postpartum incontinence was found based on method of pushing (spontaneous/directed) (P value = 0.57) or in combination with prenatal perineal massage (P value = 0.57). Fidelity to pushing treatment of type was assessed and between-groups crossover detected. Spontaneous pushing did not reduce the incidence of postpartum incontinence experienced by women 1 year after their first birth due to high cross-over between randomization groups.
NASA Technical Reports Server (NTRS)
Turner, Howard L.; Cooper, George E.
1948-01-01
A brief investigation was made of the longitudinal-stability characteristics of a YF-84A airplane (Army Serial No. 45-79488). The airplane developed a pitching-up tendency at approximately 0.80 Mach number which necessitated large push forces and down-elevator deflections for further increases in speed. In steady turns at 35,000 feet with the center of gravity at 28.3 percent mean aerodynamic chord for normal accelerations up to the maximum test value, the control-force gradients were excessive at Mach numbers over 0.78. Airplane buffeting did not present a serious problem in accelerated or unaccelerated flight at 15,000 and 35,000 feet up to the maximum test Mach number of 0.84. It is believed that excessive control force would be the limiting factor in attaining speeds in excess of 0.84 Mach number, especially at altitudes below 35,000 feet.
Ankle taping does not impair performance in jump or balance tests.
Abián-Vicén, Javier; Alegre, Luis M; Fernández-Rodríguez, J Manuel; Lara, Amador J; Meana, Marta; Aguado, Xavier
2008-01-01
This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces.
Ankle Taping Does Not Impair Performance in Jump or Balance Tests
Abián-Vicén, Javier; Alegre, Luis M.; Fernández-Rodríguez, J. Manuel; Lara, Amador J.; Meana, Marta; Aguado, Xavier
2008-01-01
This study aimed to investigate the influence of prophylactic ankle taping on two balance tests (static and dynamic balance) and one jump test, in the push off and the landing phase. Fifteen active young subjects (age: 21.0 ± 4.4 years) without previous ankle injuries volunteered for the study. Each participant performed three tests in two different situations: with taping and without taping. The tests were a counter movement jump, static balance, and a dynamic posturography test. The tests and conditions were randomly performed. The path of the center of pressures was measured in the balance tests, and the vertical ground reaction forces were recorded during the push-off and landing phases of the counter movement jump. Ankle taping had no influence on balance performance or in the push off phase of the jump. However, the second peak vertical force value during the landing phase of the jump was 12% greater with ankle taping (0.66 BW, 95% CI -0.64 to 1.96). The use of prophylactic ankle taping had no influence on the balance or jump performance of healthy young subjects. In contrast, the taped ankle increased the second peak vertical force value, which could be related to a greater risk of injury produced by the accumulation of repeated impacts in sports where jumps are frequently performed. Key pointsAnkle taping has no influence on balance performance.Ankle taping does not impair performance during the push-off phase of the jump.Ankle taping could increase the risk of injury during landings by increasing peak forces. PMID:24149902
Inoue, Yasuhiro; Hiro, Junichiro; Toiyama, Yuji; Tanaka, Koji; Uchida, Keiichi; Miki, Chikao; Kusunoki, Masato
2011-01-01
To describe our push-back approach to ultra-low anterior resection using the concept of the mucosal stump. We mobilize the rectum using an abdominal approach, and perform mucosal cutting circumferentially at the dentate line. The mucosal stump is closed, and the internal sphincteric muscle resected partially or totally according to tumor location. Perianal dissection is performed along the medial plane of the external sphincteric muscles, and the hiatal ligament is dissected posteriorly. To resect the entire rectum, the closed rectal stump is pushed back to the abdominal cavity using composed gauze. This prevents injury to the autonomic nerve. We performed colonic J-pouch anal anastomosis using our mucosal stump approach in 58 patients with rectal cancer located <4 cm from the anal verge. According to the Wexner score, 7% of patients were fully continent, 71% had acceptable function with minor continence problems, and 22% were incontinent. No patients required intermittent self-catheterization during follow-up. After a median follow-up of 49 months, there was only 1 case of local recurrence after surgery. Our push-back approach for internal sphincter resection produces satisfactory functional and oncological results in ultra-low anterior rectal cancer. Copyright © 2011 S. Karger AG, Basel.
Far Forward Life Support System (FFLSS) Phase II
2001-05-01
button will clear audible, flashing , or constant red alarms. Pushing the Config button drops down to the Level 2 menu (bottom line of Figure 8). In...disabled. Again, with testing this audible noise can be disabled. The visual flashing or constant red cannot be disabled. Pushing Return goes back to Level...Calling PLOTPIXEL( x ,y) and PLOTLINE(xl,x2,yl,y2) is as simple as pushing the appropriate bytes (unsigned integers) onto the stack and jumping to the
Energy storage by compressed air. [using windpowered pumps
NASA Technical Reports Server (NTRS)
Szego, G. C.
1973-01-01
The feasibility of windpower energy storage by compressed air is considered. The system is comprised of a compressor, a motor, and a pump turbine to store air in caverns or aquifiers. It is proposed that storage of several days worth of compressed air up to 650 pounds per square inch can be used to push the aquifier up closer to the container dome and thus initiate piston action by simply compressing air more and more. More energy can be put into it by pressure increase or pushing back the water in the aquifier. This storage system concept has reheat flexibility and lowest cost effectiveness.
Kitagawa, Taiji; Kohara, Hiroshi; Sohmura, Taiji; Takahashi, Junzo; Tachimura, Takashi; Wada, Takeshi; Kogo, Mikihiko
2004-09-01
This study examined dentoalveolar growth changes prior to the time of palatoplasty up to 3 years of age by the early two-stage Furlow and push-back methods. Thirty-four Japanese patients with complete unilateral cleft lip and palate (UCLP) treated with either a two-stage Furlow procedure (Furlow group: seven boys, eight girls) from 1998 to 2002 or a push-back procedure (push-back group; 12 boys, 7 girls) from 1993 to 1997. Consecutive plaster models were measured by three-dimensional laser scanner, before primary palatoplasty, before hard palate closure (Furlow group only), and at 3 years of age. Bite measures were taken at 3 years of age. In the Furlow group, arch length, canine width, first and second deciduous molar width and cross-sectional area, and depth and volume at midpoint showed greater growth than in the push-back group. In the Furlow group, the crossbite score was also better than in the push-back group at 3 years of age. In comparison with the push-back group, inhibition of growth impediment in the anterior region was observed in the horizontal direction in the Furlow group. In the midregion, it was observed in the horizontal and vertical directions, and in the posterior region it was observed in the horizontal direction. The results demonstrate that the early two-stage Furlow method showed progressive alveolar growth. Therefore, the early two-stage Furlow method is a more beneficial procedure than the push-back method.
The natural history of perforated marginal ulcers after gastric bypass surgery.
Altieri, Maria S; Pryor, Aurora; Yang, Jie; Yin, Donglei; Docimo, Salvatore; Bates, Andrew; Talamini, Mark; Spaniolas, Konstantinos
2018-03-01
Although perforated marginal ulcers (pMU) following Roux-en-Y Gastric Bypass (RYGB) represent a surgical emergency, the epidemiology and outcome of this condition is not well understood. The purpose of this study was to evaluate incidence of pMU following RYGB and assess the natural history of this complication. The SPARCS administrative database was used to identify patients undergoing RYGB between 2005 and 2010. With the use of a unique identifier, we followed patients up to 2014 for subsequent admission and re-intervention (repair or revision) for perforated MU. Groups were compared using Chi square tests with exact p values based on Monte Carlo simulation, t test with unequal variances, and the Wilcoxon rank-sum test when appropriate. We identified 35,080 RYGB patients; 292 patients (0.83%) developed pMU 937 (443-1546) days following RYGB [Median (Q1-Q3)]. Among these 292 patients, tobacco use was present in one-third of patients. Repair of the perforation was performed in 115 patients, while anastomotic revision was reported in 64. Patients who underwent revision were more likely to have respiratory complications. Hospital length of stay was significantly longer for patients managed with RYGB revision (Median, Q1-Q3:7, 5-14, vs 6, 4-7, days, p = 0.001). Recurrence of marginal ulcer was common after either intervention (26.09% for repair and 29.69% for revision, p = 0.726). Following RYGB, the incidence of pMU is small. Anastomotic revision for pMU is associated with prolonged length of stay compared to repair alone. Importantly, recurrence after intervention of pMU is common, suggesting possible value of a routine surveillance program for patients following pMU.
Cyclic Fiber Push-In Test Monitors Evolution of Interfacial Behavior in Ceramic Matrix Composites
NASA Technical Reports Server (NTRS)
Eldridge, Jeffrey I.
1998-01-01
SiC fiber-reinforced ceramic matrix composites are being developed for high-temperature advanced jet engine applications. Obtaining a strong, tough composite material depends critically on optimizing the mechanical coupling between the reinforcing fibers and the surrounding matrix material. This has usually been accomplished by applying a thin C or BN coating onto the surface of the reinforcing fibers. The performance of these fiber coatings, however, may degrade under cyclic loading conditions or exposure to different environments. Degradation of the coating-controlled interfacial behavior will strongly affect the useful service lifetime of the composite material. Cyclic fiber push-in testing was applied to monitor the evolution of fiber sliding behavior in both C- and BN-coated small-diameter (15-mm) SiC-fiber-reinforced ceramic matrix composites. The cyclic fiber push-in tests were performed using a desktop fiber push-out apparatus. At the beginning of each test, the fiber to be tested was aligned underneath a 10- mm-diameter diamond punch; then, the applied load was cycled between selected maximum and minimum loads. From the measured response, the fiber sliding distance and frictional sliding stresses were determined for each cycle. Tests were performed in both room air and nitrogen. Cyclic fiber push-in tests of C-coated, SiC-fiber-reinforced SiC showed progressive increases in fiber sliding distances along with decreases in frictional sliding stresses for continued cycling in room air. This rapid degradation in interfacial response was not observed for cycling in nitrogen, indicating that moisture exposure had a large effect in immediately lowering the frictional sliding stresses of C-coated fibers. These results indicate that matrix cracks bridged by C-coated fibers will not be stable, but will rapidly grow in moisture-containing environments. In contrast, cyclic fiber push-in tests of both BN-coated, SiC-fiber-reinforced SiC and BNcoated, SiC-fiber-reinforced barium strontium aluminosilicate showed no significant changes in fiber sliding behavior with continued short-term cycling in either room air or nitrogen. Although the composites with BN-coated fibers showed stable short-term cycling behavior in both environments, long-term (several-week) exposure of debonded fibers to room air resulted in dramatically increased fiber sliding distances and decreased frictional sliding stresses. These results indicate that although matrix cracks bridged by BNcoated fibers will show short-term stability, such cracks will show substantial growth with long-term exposure to moisture-containing environments. Newly formulated BN coatings, with higher moisture resistance, will be tested in the near future.
Biernat, John L.
2002-11-05
This invention generally relates to the remote removal of pelletized samples from cylindrical containment capsules. V-blocks are used to receive the samples and provide guidance to push out rods. Stainless steel liners fit into the v-channels on the v-blocks which permits them to be remotely removed and replaced or cleaned to prevent cross contamination between capsules and samples. A capsule holder securely holds the capsule while allowing manual up/down and in/out movement to align each sample hole with the v-blocks. Both end sections contain identical v-blocks; one that guides the drive out screw and rods or manual push out rods and the other to receive the samples as they are driven out of the capsule.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-17
... showerhead must be manufactured such that a pushing or pulling force of 8 lbf or more is required to remove... mechanically retained at the point of manufacture such that a pulling or pushing force of 8 lbf or more is...
Push-out bond strength of different tricalcium silicate-based filling materials to root dentin.
Stefaneli Marques, Jorge Henrique; Silva-Sousa, Yara Teresinha Corrêa; Rached-Júnior, Fuad Jacob Abi; Macedo, Luciana Martins Domingues de; Mazzi-Chaves, Jardel Francisco; Camilleri, Josette; Sousa-Neto, Manoel Damião
2018-03-08
The aim of this study was to evaluate the bond strength of different triccalcium silicate cements to retrograde cavity using a push out test. Thirty maxillary central incisors were shaped using #80 hand files and sectioned transversally. Root slices were obtained from the apical 4 mm after eliminating the apical extremity. The specimens were embedded in acrylic resin and positioned at 45° to the horizontal plane for preparation of root-end cavities with a diamond ultrasonic retrotip. The samples were divided into three groups according to the root-end filling material (n = 10): MTA Angelus, ProRoot MTA and Biodentine. A gutta-percha cone (#80) was tugged-back at the limit between the canal and the root-end cavity. The root-end cavity was filled and the gutta-percha cone was removed after complete setting of the materials. The specimens were placed in an Instron machine with the root-end filling turned downwards. The push-out shaft was inserted in the space previously occupied by the gutta-percha cone and push out testing was performed at a crosshead speed of 1.0 mm/min. There was no statistically significant difference in resistance to push out by the materials tested (p > 0.01). MTA Angelus and ProRoot MTA showed predominantly mixed failure while Biodentine exhibited mixed and cohesive failures. The tricalcium silicate-based root-end filling materials showed similar bond strength retrograde cavity.
Effectiveness of a Navy remedial exercise intervention.
Croteau, K A; Young, C J
2000-10-01
The purpose of this study was to evaluate the effectiveness of a Navy remedial exercise program (REP) in improving the physical fitness levels of its participants. Subjects were 27 Navy personnel assigned to a Northeast naval air station who had failed to pass either the body composition (circumference measures) or aerobic fitness (1.5-mile run/walk) portion of the semiannual physical readiness test. The REP consisted of three 1-hour supervised exercise sessions per week for 16 weeks, with primary emphasis on running and walking. Paired t tests revealed that the REP was effective in reducing body weight (-3.1%) and body fat (mean absolute loss of 2.7%) and in improving 1.5-mile run/walk time (-6.2%). No changes were seen in muscular endurance measures (2-minute push-ups, 2-minute curl-ups). Findings from this study indicate that improvements in PF can be attained through a 16-week Navy remedial exercise program.
Miller-Cushon, E K; DeVries, T J
2017-03-01
Feeding management factors have great potential to influence activity patterns and feeding behavior of dairy cows, which may have implications for performance. The objectives of this study were to assess the effects of feed push-up frequency on the behavioral patterns of dairy cows, and to determine associations between behavior and milk yield and composition. Lactating Holstein dairy cows (n = 28, parity = 1.9 ± 1.1; mean ± SD) were housed in tiestalls, milked twice per day, and offered ad libitum access to water and a total mixed ration (containing, on a dry matter basis: 25% corn silage, 25% grass/alfalfa haylage, 30% high-moisture corn, and 20% protein/mineral supplement), provided twice per day. Cows were divided into 2 groups of 14 (balanced by days in milk, milk production, and parity) and individually exposed to each of 2 treatments in a crossover design with 21-d periods; treatment 1 had infrequent feed push-up (3×/d), whereas treatment 2 had frequent feed push-up (5×/d). During the last 7 d of each period, dry matter intake and milk production were recorded and lying behavior was monitored using electronic data loggers. During the last 2 d of each period, milk samples were collected for analysis of protein and fat content and feed samples of fresh feed and orts were collected for particle size analysis. The particle size separator had 3 screens (19, 8, and 1.18 mm) and a bottom pan, resulting in 4 fractions (long, medium, short, fine). Sorting was calculated as the actual intake of each particle size fraction expressed as a percentage of the predicted intake of that fraction. Feed push-up frequency had no effect on lying time [11.4 ± 0.37 h/d; mean ± standard error (SE)], milk production (40.2 ± 1.28 kg/d) and composition (milk protein: 3.30 ± 0.048%; milk fat: 3.81 ± 0.077%), or feed sorting. Cows sorted against long particles (78.0 ± 2.2%) and for short (102.6 ± 0.6%) and fine (108.4 ± 0.9%) particles. Milk fat content decreased by 0.1 percentage points for every 10% increase in sorting against long particles and was not associated with lying behavior or other cow-level factors. Milk protein content decreased by 0.03 percentage points for every hour decrease in lying time and by 0.04 percentage points for every 10% increase in sorting against long particles. These results suggest that sorting against long ration particles may negatively affect milk composition. Additionally, we did not find that altering feed push-up frequency affected feed sorting or cow standing and lying patterns. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Range of Motion of the Ankle According to Pushing Force, Gender and Knee Position
Cho, Kang Hee; Lee, Hyunkeun
2016-01-01
Objective To investigate the difference of range of motion (ROM) of ankle according to pushing force, gender and knee position. Methods One hundred and twenty-eight healthy adults (55 men, 73 women) between the ages of 20 and 51, were included in the study. One examiner measured the passive range of motion (PROM) of ankle by Dualer IQ Inclinometers and Commander Muscle Testing. ROM of ankle dorsiflexion (DF) and plantarflexion (PF) according to change of pushing force and knee position were measured at prone position. Results There was significant correlation between ROM and pushing force, the more pushing force leads the more ROM at ankle DF and ankle PF. Knee flexion of 90° position showed low PF angle and high ankle DF angle, as compared to the at neutral position of knee joint. ROM of ankle DF for female was greater than for male, with no significant difference. ROM of ankle PF for female was greater than male regardless of the pushing force. Conclusion To our knowledge, this is the first study to assess the relationship between pushing force and ROM of ankle joint. There was significant correlation between ROM of ankle and pushing force. ROM of ankle PF for female estimated greater than male regardless of the pushing force and the number of measurement. The ROM of the ankle is measured differently according to the knee joint position. Pushing force, gender and knee joint position are required to be considered when measuring the ROM of ankle joint. PMID:27152277
Geostatistical analysis of centimeter-scale hydraulic conductivity variations at the MADE site
NASA Astrophysics Data System (ADS)
Bohling, Geoffrey C.; Liu, Gaisheng; Knobbe, Steven J.; Reboulet, Edward C.; Hyndman, David W.; Dietrich, Peter; Butler, James J., Jr.
2012-02-01
Spatial variations in hydraulic conductivity (K) provide critical controls on solute transport in the subsurface. Recently, new direct-push tools were developed for high-resolution characterization of K variations in unconsolidated settings. These tools were applied to obtain 58 profiles (vertical resolution of 1.5 cm) from the heavily studied macrodispersion experiment (MADE) site. We compare the data from these 58 profiles with those from the 67 flowmeter profiles that have served as the primary basis for characterizing the heterogeneous aquifer at the site. Overall, the patterns of variation displayed by the two data sets are quite similar, in terms of both large-scale structure and autocorrelation characteristics. The direct-push K values are, on average, roughly a factor of 5 lower than the flowmeter values. This discrepancy appears to be attributable, at least in part, to opposite biases between the two methods, with the current versions of the direct-push tools underestimating K in the highly permeable upper portions of the aquifer and the flowmeter overestimating K in the less permeable lower portions. The vertically averaged K values from a series of direct-push profiles in the vicinity of two pumping tests at the site are consistent with the K estimates from those tests, providing evidence that the direct-push estimates are of a reasonable magnitude. The results of this field demonstration show that direct-push profiling has the potential to characterize highly heterogeneous aquifers with a speed and resolution that has not previously been possible.
Enhancing Medical Student Education by Implementing a Competency-Based Ophthalmology Curriculum.
Succar, Tony; McCluskey, Peter; Grigg, John
2017-01-01
To evaluate innovative educational strategies that help optimize ophthalmology teaching in a crowded medical curriculum. The knowledge acquisition and perceptions of medical students undertaking the revised competency-based curriculum were compared with the prior content-based curriculum within the Sydney Medical Program. A mixed-methods research design was employed to include both quantitative and qualitative dimensions in evaluating the revised curriculum with medical students (n = 328) undergoing their ophthalmology rotation. Quantitative evaluation was performed with a 20-item multiple choice pre- and post-test of ophthalmic knowledge. A 12-month follow-up test was readministered to compare the long-term retention rate of graduates. Qualitative evaluation was measured with student satisfaction questionnaires. In the original curriculum there was an improvement of 19.9% from pre- to post-test scores [2.15; 95% confidence interval (CI), 1.35-2.94; P < 0.001] and a greater improvement of 31.6% from pre- to post-test (3.50; 95% CI, 3.03-3.97; P < 0.001) in the revised curriculum. When assessing retained knowledge at 12 months, students from the revised curriculum scored 11.5% higher than students from the original curriculum (1.56; 95% CI, 0.42-2.71; P = 0.008). In addition, qualitative feedback also improved, with the rotation being highly valued. The revised ophthalmic curriculum resulted in an increase in academic performance and a higher degree of student satisfaction. Given the gradual decline of ophthalmic education in the standard medical school curriculum, our results are timely in providing guidance for minimum ophthalmic curriculum exposure and strategies to improve ophthalmic education in medical schools. Copyright© 2017 Asia-Pacific Academy of Ophthalmology.
Should Social Workers Use "Diagnostic and Statistical Manual of Mental Disorders-5?"
ERIC Educational Resources Information Center
Frances, Allen; Jones, K. Dayle
2014-01-01
Up until now, social workers have depended on the "Diagnostic and Statistical Manual of Mental Disorders" ("DSM") as the primary diagnostic classification for mental disorders. However, the "DSM-5" revision includes scientifically unfounded, inadequately tested, and potentially dangerous diagnoses that may lead them…
Hanney, William J.; Kolber, Morey J.; Davies, George J.; Riemann, Bryan
2011-01-01
Introduction: Understanding the relationships between performance tests and sport activity is important to the rehabilitation specialist. The purpose of this study was two- fold: 1) To identify if relationships exist between tests of upper body strength and power (Single Arm Seated Shot Put, Timed Push-Up, Timed Modified Pull-Up, and The Davies Closed Kinetic Chain Upper Extremity Stability Test, and the softball throw for distance), 2) To determine which variable or group of variables best predicts the performance of a sport specific task (the softball throw for distance). Methods: One hundred eighty subjects (111 females and 69 males, aged 18-45 years) performed the 5 upper extremity tests. The Pearson product moment correlation and a stepwise regression were used to determine whether relationships existed between performance on the tests and which upper extremity test result best explained the performance on the softball throw for distance. Results: There were significant correlations (r=.33 to r=.70, p=0.001) between performance on all of the tests. The modified pull-up test was the best predictor of the performance on the softball throw for distance (r2= 48.7), explaining 48.7% of variation in performance. When weight, height, and age were added to the regression equation the r2 values increased to 64.5, 66.2, and 67.5 respectively. Conclusion: The results of this study indicate that several upper extremity tests demonstrate significant relationships with one another and with the softball throw for distance. The modified pull up test was the best predictor of performance on the softball throw for distance. PMID:21712942
Levy, Ayelet; Kopplin, Kara; Gefen, Amit
2013-12-01
Pressure ulcers (PUs) are common in patients who chronically depend on a wheelchair for mobility, such as those with a spinal cord injury (SCI). In attempt to prevent the formation of PUs, pressure relieving maneuvers, such as push-ups, are commonly recommended for individuals with SCI. However, very little is known about skin and subcutaneous fat tissue load distributions during sitting and in particular their development during the process of regaining weight-bearing after a push-up. Knowledge on how these loads evolve during sitting-down is critical for understanding the susceptibility of skin to PUs. Considering the potential practical implications on guidelines for wheelchair users, we studied herein the build-up of shear loads in skin and subcutaneous fat using a model of the buttocks of a single SCI subject. Using 12 variants of our finite element (FE) model, we determined the shear loads in skin and subcutaneous fat tissues under the ischial tuberosities when sitting down on foam cushions with different stiffness properties, in healthy skin and scarred skin conditions, focusing on the time course of the build-up of tissue loads. We found substantial differences between the loading curves of skin and fat: While the fat was loaded at a nearly constant rate, skin loads increased nonlinearly - with a greater load/time slope at early skin-support contact. In the context of tissue health and prevention of PUs, this indicates that the more sensitive period with respect to skin integrity is at initial skin-support contact. We further found that the edges of a pre-existing scar are more susceptible to injury, and the greater risk for that is when a hypertrophic scar is present. Despite that this is a theoretical modeling study with associated limitations, we believe that it is already appropriate to recommend to patients to reposition themselves gradually and gently, and not to "fall" back into the wheelchair after finishing a push-up maneuver. Copyright © 2013 Elsevier Ltd. All rights reserved.
Pilot investigation - Nominal crew induced forces in zero-g
NASA Technical Reports Server (NTRS)
Klute, Glenn K.
1992-01-01
This report presents pilot-study data of test subject forces induced by intravehicular activities such as push-offs and landings with both hands and feet. Five subjects participated in this investigation. Three orthogonal force axes were measured in the NASA KC-135 research aircraft's 'zero-g' environment. The largest forces were induced during vertical foot push-offs, including one of 534 newtons (120 lbs). The mean vertical foot push-off was 311 newtons (70 lbs). The vertical hand push-off forces were also relatively large, including one of 267 newtons (60 lbs) with a mean of 151 newtons (34 lbs). These force magnitudes of these forces would result in a Shuttle gravity environment of about 1 x exp 10 -4 g's.
Ma, Y.F.; Xiao, C.
2013-01-01
The push-pull effects of three plant secondary metabolites, azadirachtin, eucalyptol, and heptanal, on the oviposition choices of potato tubers by the potato tuber moth, Phthorimaea operculella (Zeller) (Lepidoptera: Gelechiidae) were tested in the laboratory. Azadirachtin at concentrations from 1.5 to 12 mg/L had a significant repellent effect on oviposition. Eucalyptol at concentrations from 3 to 12 mg/L promoted oviposition. Heptanal promoted oviposition at low concentrations from 0.1875 to 3.0 mg/L but repelled it at higher concentrations from 12 to 24 mg/L. The combination of azadirachtin (12 mg/L) with eucalyptol (3.0 mg/L) resulted in a significant pushpull effect of 56.3% on oviposition. The average maximum push-pull effects occurred with the combinations of azadirachtin with heptanal (12 and 0.375 mg/L, respectively; 38.7% push-pull effect), heptanal with eucalyptol (12 and 6 mg/L, respectively; 31.4% push-pull effect), and heptanal (high concentration) with heptanal (low concentration) (12.0 and 0.375 mg/L, respectively; 25% push-pull effect). PMID:24786822
NASA Astrophysics Data System (ADS)
Hansen, S. K.; Berkowitz, B.
2014-12-01
Recently, we developed an alternative CTRW formulation which uses a "latching" upscaling scheme to rigorously map continuous or fine-scale stochastic solute motion onto discrete transitions on an arbitrarily coarse lattice (with spacing potentially on the meter scale or more). This approach enables model simplification, among many other things. Under advection, for example, we see that many relevant anomalous transport problems may be mapped into 1D, with latching to a sequence of successive, uniformly spaced planes. On this formulation (which we term RP-CTRW), the spatial transition vector may generally be made deterministic, with CTRW waiting time distributions encapsulating all the stochastic behavior. We demonstrate the excellent performance of this technique alongside Pareto-distributed waiting times in explaining experiments across a variety of scales using only two degrees of freedom. An interesting new application of the RP-CTRW technique is the analysis of radial (push-pull) tracer tests. Given modern computational power, random walk simulations are a natural fit for the inverse problem of inferring subsurface parameters from push-pull test data, and we propose them as an alternative to the classical type curve approach. In particular, we explore the visibility of heterogeneity through non-Fickian behavior in push-pull tests, and illustrate the ability of a radial RP-CTRW technique to encapsulate this behavior using a sparse parameterization which has predictive value.
Comparative durability and costs analysis of ventricular shunts.
Agarwal, Nitin; Kashkoush, Ahmed; McDowell, Michael M; Lariviere, William R; Ismail, Naveed; Friedlander, Robert M
2018-05-11
OBJECTIVE Ventricular shunt (VS) durability has been well studied in the pediatric population and in patients with normal pressure hydrocephalus; however, further evaluation in a more heterogeneous adult population is needed. This study aims to evaluate the effect of diagnosis and valve type-fixed versus programmable-on shunt durability and cost for placement of shunts in adult patients. METHODS The authors retrospectively reviewed the medical records of all patients who underwent implantation of a VS for hydrocephalus at their institution over a 3-year period between August 2013 and October 2016 with a minimum postoperative follow-up of 6 months. The primary outcome was shunt revision, which was defined as reoperation for any indication after the initial procedure. Supply costs, shunt durability, and hydrocephalus etiologies were compared between fixed and programmable valves. RESULTS A total of 417 patients underwent shunt placement during the index time frame, consisting of 62 fixed shunts (15%) and 355 programmable shunts (85%). The mean follow-up was 30 ± 12 (SD) months. The shunt revision rate was 22% for programmable pressure valves and 21% for fixed pressure valves (HR 1.1 [95% CI 0.6-1.8]). Shunt complications, such as valve failure, infection, and overdrainage, occurred with similar frequency across valve types. Kaplan-Meier survival curve analysis showed no difference in durability between fixed (mean 39 months) and programmable (mean 40 months) shunts (p = 0.980, log-rank test). The median shunt supply cost per index case and accounting for subsequent revisions was $3438 (interquartile range $2938-$3876) and $1504 (interquartile range $753-$1584) for programmable and fixed shunts, respectively (p < 0.001, Wilcoxon rank-sum test). Of all hydrocephalus etiologies, pseudotumor cerebri (HR 1.9 [95% CI 1.2-3.1]) and previous shunt malfunction (HR 1.8 [95% CI 1.2-2.7]) were found to significantly increase the risk of shunt revision. Within each diagnosis, there were no significant differences in revision rates between shunts with a fixed valve and shunts with a programmable valve. CONCLUSIONS Long-term shunt revision rates are similar for fixed and programmable shunt pressure valves in adult patients. Hydrocephalus etiology may play a significant role in predicting shunt revision, although programmable valves incur higher supply costs regardless of initial diagnosis. Utilization of fixed pressure valves versus programmable pressure valves may reduce supply costs while maintaining similar revision rates. Given the importance of developing cost-effective management protocols, this study highlights the critical need for large-scale prospective observational studies and randomized clinical trials of ventricular shunt valve revisions and additional patient-centered outcomes.
Push-out tests on a new silicon carbide/reaction-bonded silicon carbide ceramic matrix composite
NASA Technical Reports Server (NTRS)
Curtin, William A.; Eldridge, Jeffrey I.; Srinivasan, Gajawalli V.
1993-01-01
Fiber push-out tests have been performed on a ceramic matrix composite consisting of carborundum-sintered SiC fibers, with a BN coating, embedded in a reaction-bonded SiC matrix. Analysis of the push-out data, utilizing the most complete theory presently available, shows that one of the fiber/coating/matrix interfaces has a low fracture energy (one-tenth that of the fiber) and a moderate sliding resistance of about 8 MPa. The debonded sliding interface shows some continuous but minor abrasion, which appears to increase the sliding resistance, but overall the system exhibits very clean smooth sliding. The tensile response of a full-scale composite is then modeled using data obtained here and known fiber strengths to demonstrate the good composite behavior predicted for this material.
Pereira, Jefferson Ricardo; Rosa, Ricardo Abreu da; Só, Marcus Vinícius Reis; Afonso, Daniele; Kuga, Milton Carlos; Honório, Heitor Marques; Valle, Accácio Lins do; Vidotti, Hugo Alberto
2014-01-01
The purpose of this study was to assess the push-out bond strength of glass fiber posts to root dentin after cementation with glass ionomer (GICs) and resinmodified glass ionomer cements (RMGICs). Fifty human maxillary canines were transversally sectioned at 15 mm from the apex. Canals were prepared with a step back technique until the application of a #55 K-file and filled. Post spaces were prepared and specimens were divided into five groups according to the cement used for post cementation: Luting & Lining Cement; Fuji II LC Improved; RelyX Luting; Ketac Cem; and Ionoseal. After cementation of the glass fiber posts, all roots were stored at 100% humidity until testing. For push-out test, 1-mm thick slices were produced. The push-out test was performed in a universal testing machine at a crosshead speed of 0.5 mm/minute and the values (MPa) were analyzed by Kolmogorov-Smirnov and Levene's tests and by two-way ANOVA and Tukey's post hoc test at a significance level of 5%. Fiber posts cemented using Luting & Lining Cement, Fuji II LC Improved, and Ketac Cem presented the highest bond strength to root dentin, followed by RelyX Luting. Ionoseal presented the lowest bond strength values (P>0.05). The post level did not influence the bond strength of fiber posts to root dentin (P=0.148). The major cause of failure was cohesive at the cement for all GICs and RMGICs. Except for Ionoseal, all cements provided satisfactory bond strength values.
PEREIRA, Jefferson Ricardo; da ROSA, Ricardo Abreu; SÓ, Marcus Vinícius Reis; AFONSO, Daniele; KUGA, Milton Carlos; HONÓRIO, Heitor Marques; do VALLE, Accácio Lins; VIDOTTI, Hugo Alberto
2014-01-01
Objective The purpose of this study was to assess the push-out bond strength of glass fiber posts to root dentin after cementation with glass ionomer (GICs) and resin-modified glass ionomer cements (RMGICs). Material and Methods Fifty human maxillary canines were transversally sectioned at 15 mm from the apex. Canals were prepared with a step back technique until the application of a #55 K-file and filled. Post spaces were prepared and specimens were divided into five groups according to the cement used for post cementation: Luting & Lining Cement; Fuji II LC Improved; RelyX Luting; Ketac Cem; and Ionoseal. After cementation of the glass fiber posts, all roots were stored at 100% humidity until testing. For push-out test, 1-mm thick slices were produced. The push-out test was performed in a universal testing machine at a crosshead speed of 0.5 mm/minute and the values (MPa) were analyzed by Kolmogorov-Smirnov and Levene's tests and by two-way ANOVA and Tukey's post hoc test at a significance level of 5%. Results Fiber posts cemented using Luting & Lining Cement, Fuji II LC Improved, and Ketac Cem presented the highest bond strength to root dentin, followed by RelyX Luting. Ionoseal presented the lowest bond strength values (P>0.05). The post level did not influence the bond strength of fiber posts to root dentin (P=0.148). The major cause of failure was cohesive at the cement for all GICs and RMGICs. Conclusions Except for Ionoseal, all cements provided satisfactory bond strength values. PMID:25004052
NASA Astrophysics Data System (ADS)
Mickler, P. J.; Yang, C.; Lu, J.; Reedy, R. C.; Scanlon, B. R.
2012-12-01
Carbon Capture Utilization and Storage projects (CCUS), where CO2 is captured at point sources such as power stations and compressed into a supercritical liquid for underground storage, has been proposed to reduce atmospheric CO2 and mitigate global climate change. Problems may arise from CO2 releases along discreet pathways such as abandoned wells and faults, upwards and into near surface groundwater. Migrating CO2 may inversely impact fresh water resources by increasing mineral solubility and dissolution rates and mobilizing harmful trace elements including As and Pb. This study addresses the impacts on fresh water resources through a combination of laboratory batch experiments, where aquifer sediment are reacted in their corresponding groundwater in 100% CO2 environments, and field push-pull tests where groundwater is equilibrated with 100% CO2, reacted in-situ in the groundwater system, and pulled out for analyses. Batch experiments were performed on aquifer material from carbonate dominated, mixed carbonate/silicalstic, and siliclastic dominated systems. A mixed silicalstic/carbonate system was chosen for the field based push-pull test. Batch experiment results suggest carbonate dissolution increased the concentration of Ca, Mg, Sr, Ba, Mn, U and HCO3- in groundwater. In systems with significant carbonate content, dissolution continued until carbonate saturation was achieved at approximately 1000 hr. Silicate dissolution increased the conc. of Si, K Ni and Co, but at much lower rates than carbonate dissolution. The elements As, Mo, V, Zn, Se and Cd generally show similar behavior where concentrations initially increase but soon drop to levels at or below the background concentrations (~48 hours). A Push-Pull test on one aquifer system produced similar geochemical behavior but observed reaction rates are higher in batch experiments relative to push-pull tests. Release of CO2 from CCUS sites into overlying aquifer systems may adversely impact groundwater quality primarily through carbonate dissolution which releases Ca and elements that substitute for Ca in crystal lattices. Silicate weathering releases primarily Si and K at lower rates. Chemical changes with the addition of CO2 may initially mobilize As, Mo, V, Zn, Se and Cd but these elements become immobile in the lowered pH water and sorb onto aquifer minerals. A combined laboratory batch experiment and field push-pull test in fresh water aquifers overlying CCUS projects will best characterize the response of the aquifer to increased pCO2. The long experimental duration of the batch experiments may allow reactions to reach equilibrium however; reaction rates may be artificially high due to increased mineral surface areas. Field based push-pull tests offer a more realistic water rock ratio and test a much larger volume of aquifer material but the test must be shorter in duration because the high pCO2 water is subject to mixing with low pCO2 background water and migration away from the test well with groundwater flow. A comparison of the two methods best characterizes the potential effects on groundwater chemistry
Levine, Brett R; Della Valle, Craig J; Deirmengian, Carl A; Breien, Kristoffer M; Weeden, Steven H; Sporer, Scott M; Paprosky, Wayne G
2008-12-01
A retrospective cohort study of 31 hips revised with a tripolar articular construct was performed. Patient demographics and preoperative and postoperative information were recorded. Indications for a tripolar construct were recurrent dislocation and the inability to attain intraoperative stability during hip revision. Nine patients (29%) were revised to the tripolar construct after failure of a constrained liner. Twenty patients (65%) had at least one episode of instability before the most recent revision. At a mean follow-up of 38 months, modified Postel scores improved from a mean of 5.28 to 9.64 (P < .01). Radiographic follow-up revealed no evidence of component loosening/migration, osteolysis, or polyethylene wear. Two patients (7%) required further revision surgery for recurrent instability. A tripolar construct was effective in eliminating or preventing instability in 93% of the complex cases treated. These early results support the use of a tripolar construct in treating recurrent instability or instability encountered at the time of revision hip arthroplasty.
A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation.
Ward, W Kenneth; Jansen, Lawrence B; Anderson, Ellen; Reach, Gerard; Klein, Jean-Claude; Wilson, George S
2002-03-01
For biosensor fabrication, it is important to optimize materials and methods in order to create predictable function in vitro and in vivo. For this reason, we designed a new glucose sensor ('revised protocol') that utilized an outer permselective membrane made of amphiphobic polyurethane which allows glucose passage through hydrophilic segments. An inner polyethersulfone membrane, stabilized with a trimethoxysilane, provided specificity. Before application of the inner membrane, it was necessary to etch the platinum electrode with a radio frequency oxygen plasma. The revised protocol sensors (n=185) were compared with sensors fabricated with an earlier ('original') protocol (n=204) which used an outer polyurethane without hydrophilic segments and a complex inner membrane of cellulose acetate and Nafion. The function of revised protocol sensors was more predictable in vitro as evidenced by a much lower variation of glucose sensitivity than the original protocol sensors. Revised and original protocol sensors were nearly linear up to a glucose concentration of 20 mM. In vitro interference from 0.1 mM acetaminophen was minimal in both groups of sensors and would be expected to represent about 2% of the total sensor response at normal glucose levels for revised protocol sensors. Prolonged testing of the revised protocol sensors for 11 days during immersion in buffer revealed stable sensitivities (day 1: 6.12+/-1.34 nA/mM; day 3: 6.33+/-1.40; day 8: 7.13+/-1.39; and day 11: 7.56+/-1.47; sensitivity for day 1 vs. each other day: not significant) and no critical loss of glucose oxidase activity. The response of the revised protocol sensors (n=7) to intraperitoneal glucose was tested in rats approximately one day after subcutaneous implantation and the sensors tracked glucose closely with a slight lag of 3-6 min.
The effects of lip revision surgery on nasolabial esthetics in patients with cleft lip.
Mercado, A M; Phillips, C; Vig, K W L; Trotman, C-A
2014-11-01
1) To determine the concordance among surgeons on subjective assessments of nasolabial esthetics in children with repaired cleft lip; and 2) to evaluate longitudinal changes in nasolabial esthetics in relation to cleft lip revision surgery. School of Dentistry at University of North Carolina, Chapel Hill. Children with repaired unilateral cleft lip: 32 had lip revision surgery and 27 did not have surgery. Retrospective observational study from a non-randomized clinical trial. Ratings of nasolabial esthetics performed by six surgeons using the Asher-McDade scale at baseline and 12-month follow-up. Concordance among surgeons ranged from poor to acceptable. Nasolabial ratings at follow-up were better in the Revision group than in the Non-Revision group, although differences were small. The most prevalent change in the Revision Group was improvement in one or more units on the scale, while 'no change' was most prevalent in the Non-Revision group. Participants in the Revision group were more likely to receive a 'no' in relation to the need for lip or nose revision at the follow-up visit. There were mild esthetic improvements observed in relation to lip revision surgery, which should be interpreted with caution given the subjectivity of the rating method used. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
USDA-ARS?s Scientific Manuscript database
A protocol has been developed for the indoor evaluation of candidate spatial repellents intended for use in push and pull systems. Single treatments (catnip oil, 1-methylpiperazine and homopiperazine) and a mixture of catnip oil and homopiperazine were tested with yellow-fever mosquitoes (Aedes aegy...
Please, Not Another Push to Get Tough on Student Retention
ERIC Educational Resources Information Center
Norton, M. Scott
2011-01-01
Standardized academic testing, under-performing schools, demands for high standards in America's schools and current levels of student dropouts have resulted in renewed calls for "getting tough on student retention." The push for student retention is demanded by school boards and others in spite of the overwhelming research evidence that…
Is there a need for routine follow-up after primary total hip arthroplasty?
Hacking, Craig; Weinrauch, Patrick; Whitehouse, Sarah L; Crawford, Ross W; Donnelly, William J
2010-10-01
The objective of routine outpatient assessment of well-functioning patients after primary total hip arthroplasty (THA) is to detect asymptomatic failure of prostheses to guide recommendations for early intervention. We have observed that the revision of THAs in asymptomatic patients is highly uncommon. We therefore question the need for routine follow-up of patients after THA. A prospective analysis of an orthopaedic database identified 158 patients who received 177 revision THAs over a four-year period. A retrospective chart review was conducted. Patient demographics, primary and revision surgery parameters and follow-up information were recorded and cross-referenced with Australian Orthopaedic Association National Joint Replacement Registry data. One hundred ten THAs in 104 patients (average age 70.4 (SD 9.8 years)). There were 70 (63.6%) in total, 13 (11.8%) femoral and 27 (24.5%) acetabular revisions. The indications for revision were aseptic loosening (70%), dislocation (8.2%), peri-prosthetic fracture (7.3%), osteolysis (6.4%) and infection (4.5%). Only four (3.6%) were asymptomatic revisions. A mean of 5.3 (SD 5.2 and 1.9 (SD 5.3)) follow-up appointments were required before revision in patients with and without symptoms, respectively. The average time from the primary to revision surgery was 11.8 (SD 7.23) years. We conclude that patients with prostheses with excellent long-term clinical results as validated by joint registries, routine follow-up of asymptomatic THA should be questioned and requires further investigation. Based on the work of this study, the current practice of routine follow-up of asymptomatic THA may be excessively costly and unnecessary, and a less resource-intensive review method may be more appropriate. © 2010 The Authors. ANZ Journal of Surgery © 2010 Royal Australasian College of Surgeons.
Bergmann, Jeannine; Krewer, Carmen; Rieß, Katrin; Müller, Friedemann; Koenig, Eberhard; Jahn, Klaus
2014-07-01
To compare the classification of two clinical scales for assessing pusher behaviour in a cohort of stroke patients. Observational case-control study. Inpatient stroke rehabilitation unit. A sample of 23 patients with hemiparesis due to a unilateral stroke (1.6 ± 0.7 months post stroke). Immediately before and after three different interventions, the Scale for Contraversive Pushing and the Burke Lateropulsion Scale were applied in a standardized procedure. The diagnosis of pusher behaviour on the basis of the Scale for Contraversive Pushing and the Burke Lateropulsion Scale differed significantly (χ2 = 54.260, p < 0.001) resulting in inconsistent classifications in 31 of 138 cases. Changes immediately after the interventions were more often detected by the Burke Lateropulsion Scales than by the Scale for Contraversive Pushing (χ2 = 19.148, p < 0.001). All cases with inconsistent classifications showed no pusher behaviour on the Scale for Contraversive Pushing, but pusher behaviour on the Burke Lateropulsion Scale. 64.5% (20 of 31) of them scored on the Burke Lateropulsion Scale on the standing and walking items only. The Burke Lateropulsion Scale is an appropriate alternative to the widely used Scale for Contraversive Pushing to follow-up patients with pusher behaviour (PB); it might be more sensitive to detect mild pusher behaviour in standing and walking. © The Author(s) 2014.
Lv, Xiaomei; Xie, Wenping; Lu, Wenqiang; Guo, Fei; Gu, Jiali; Yu, Hongwei; Ye, Lidan
2014-09-30
To explore the capacity of isoprene production in Saccharomyces cerevisiae, a rational push-pull-restrain strategy was proposed to engineer the mevalonic acid (MVA) and acetyl-CoA pathways. The strategy can be decomposed into the up-regulation of precursor supply in the acetyl-CoA module and the MVA pathway (push-strategy), increase of the isoprene branch flux (pull-strategy), and down-regulation of the competing pathway (restrain-strategy). Furthermore, to reduce the production cost arising from galactose addition and meanwhile maintain the high expression of Gal promoters, the galactose regulatory network was modulated by Gal80p deletion. Finally, the engineered strain YXM10-ispS-ispS could accumulate up to 37 mg/L isoprene (about 782-fold increase compared to the parental strain) under aerobic conditions with glycerol-sucrose as carbon source. In this way, a new potential platform for isoprene production was established via metabolic engineering of the yeast native pathways. Copyright © 2014 Elsevier B.V. All rights reserved.
Improved Training Method for Rapid Rehabilitation of Amputees
2015-05-01
Falls Overall Project Summary This report describes a four year research effort to develop and test a novel training technique aimed at increasing...month post training assessment. One subject moved after completing the training and did not return for follow-up. Three subjects failed to respond to...training (n=5) Reasons: Moved, revisions, suicide attempt, time conflict Completed Training (n= 20) Completed post - testing (n=20). Lost to
Preparing for LSST with the LCOGT NEO Follow-up Network
NASA Astrophysics Data System (ADS)
Greenstreet, Sarah; Lister, Tim; Gomez, Edward
2016-10-01
The Las Cumbres Observatory Global Telescope Network (LCOGT) provides an ideal platform for follow-up and characterization of Solar System objects (e.g. asteroids, Kuiper Belt Objects, comets, Near-Earth Objects (NEOs)) and ultimately for the discovery of new objects. The LCOGT NEO Follow-up Network is using the LCOGT telescope network in addition to a web-based system developed to perform prioritized target selection, scheduling, and data reduction to confirm NEO candidates and characterize radar-targeted known NEOs.In order to determine how to maximize our NEO follow-up efforts, we must first define our goals for the LCOGT NEO Follow-up Network. This means answering the following questions. Should we follow-up all objects brighter than some magnitude limit? Should we only focus on the brightest objects or push to the limits of our capabilities by observing the faintest objects we think we can see and risk not finding the objects in our data? Do we (and how do we) prioritize objects somewhere in the middle of our observable magnitude range? If we want to push to faint objects, how do we minimize the amount of data in which the signal-to-noise ratio is too low to see the object? And how do we find a balance between performing follow-up and characterization observations?To help answer these questions, we have developed a LCOGT NEO Follow-up Network simulator that allows us to test our prioritization algorithms for target selection, confirm signal-to-noise predictions, and determine ideal block lengths and exposure times for observing NEO candidates. We will present our results from the simulator and progress on our NEO follow-up efforts.In the era of LSST, developing/utilizing infrastructure, such as the LCOGT NEO Follow-up Network and our web-based platform for selecting, scheduling, and reducing NEO observations, capable of handling the large number of detections expected to be produced on a daily basis by LSST will be critical to follow-up efforts. We hope our work can act as an example and tool for the community as together we prepare for the age of LSST.
Marcolin, Giuseppe; Petrone, Nicola; Moro, Tatiana; Battaglia, Giuseppe; Bianco, Antonino; Paoli, Antonio
2015-01-01
Context The push-up is a widely used exercise for upper limb strengthening that can be performed with many variants. A comprehensive analysis of muscle activation during the ascendant phase (AP) and descendant phase (DP) in different variants could be useful for trainers and rehabilitators. Objective To obtain information on the effect of different push-up variants on the electromyography (EMG) of a large sample of upper limb muscles and to investigate the role of the trunk and abdomen muscles during the AP and DP. Design Cross-sectional study. Setting University laboratory. Patients or Other Participants Eight healthy, young volunteers without a history of upper extremity or spine injury. Intervention(s) Participants performed a set of 10 repetitions for each push-up variant: standard, wide, narrow, forward (FP), and backward (BP). Surface EMG of 12 selected muscles and kinematics data were synchronously recorded to describe the AP and DP. Main Outcome Measure(s) Mean EMG activity of the following muscles was analyzed: serratus anterior, deltoideus anterior, erector spinae, latissimus dorsi, rectus abdominis, triceps brachii caput longus, triceps brachii caput lateralis, obliquus externus abdominis, pectoralis major sternal head, pectoralis major clavicular head, trapezius transversalis, and biceps brachii. Results The triceps brachii and pectoralis major exhibited greater activation during the narrow-base variant. The highest activation of abdomen and back muscles was recorded for the FP and BP variants. The DP demonstrated the least electrical activity across all muscles, with less marked differences for the abdominal and erector spinae muscles because of their role as stabilizers. Conclusions Based on these findings, we suggest the narrow-base variant to emphasize triceps and pectoralis activity and the BP variant for total upper body strength conditioning. The FP and BP variants should be implemented carefully in participants with low back pain because of the greater activation of abdominal and back muscles. PMID:26488636
Clinical tests of ankle plantarflexor strength do not predict ankle power generation during walking.
Kahn, Michelle; Williams, Gavin
2015-02-01
The aim of this study was to investigate the relationship between a clinical test of ankle plantarflexor strength and ankle power generation (APG) at push-off during walking. This is a prospective cross-sectional study of 102 patients with traumatic brain injury. Handheld dynamometry was used to measure ankle plantarflexor strength. Three-dimensional gait analysis was performed to quantify ankle power generation at push-off during walking. Ankle plantarflexor strength was only moderately correlated with ankle power generation at push-off (r = 0.43, P < 0.001; 95% confidence interval, 0.26-0.58). There was also a moderate correlation between ankle plantarflexor strength and self-selected walking velocity (r = 0.32, P = 0.002; 95% confidence interval, 0.13-0.48). Handheld dynamometry measures of ankle plantarflexor strength are only moderately correlated with ankle power generation during walking. This clinical test of ankle plantarflexor strength is a poor predictor of calf muscle function during gait in people with traumatic brain injury.
Optimization and application of blasting parameters based on the "pushing-wall" mechanism
NASA Astrophysics Data System (ADS)
Ren, Feng-yu; Sow, Thierno Amadou Mouctar; He, Rong-xing; Liu, Xin-rui
2012-10-01
The large structure parameter of a sublevel caving method was used in Beiminghe iron mine. The ores were generally lower than the medium hardness and easy to be drilled and blasted. However, the questions of boulder yield, "pushing-wall" accident rate, and brow damage rate were not effectively controlled in practical blasting. The model test of a similar material shows that the charge concentration of bottom blastholes in the sector is too high; the pushing wall is the fundamental reason for the poor blasting effect. One of the main methods to adjust the explosive distribution is to increase the length of charged blastholes. Therefore, the field tests with respect to increasing the length of uncharged blastholes were made in 12# stope of -95 subsection and 6# stope of Beiminghe iron mine. This paper took the test result of 12# stope as an example to analyze the impact of charge structure on blasting effect and design an appropriate blasting parameter that is to similar to No.12 stope.
Development of Minimum Physical Fitness Standards for the Canadian Armed Forces. Phase 3
1988-03-01
while mounting stairs more than tripled their energy expenditures . Similarly, Astrand and Rodahl (1977) determined that continuous stair climbing...evacuation tasks were restructured to be one-person tasks (i.e., wheels on the land stretcher; a push-skid for the sea evacuation stairs stretcher). Other...kg stoker stretcher 12.5 m to the base of a flight of stairs . The subject then pushed a skid carrying one subject’s share of the mass up and down a
Code of Fair Testing Practices in Education (Revised)
ERIC Educational Resources Information Center
Educational Measurement: Issues and Practice, 2005
2005-01-01
A note from the Working Group of the Joint Committee on Testing Practices: The "Code of Fair Testing Practices in Education (Code)" prepared by the Joint Committee on Testing Practices (JCTP) has just been revised for the first time since its initial introduction in 1988. The revision of the Code was inspired primarily by the revision of…
Three-peat NREL Intern Pushes Boundaries of Early-Stage Fuels Research on
Early-Stage Fuels Research on Way to Master's Degree Three-peat NREL Intern Pushes Boundaries of Early -Stage Fuels Research on Way to Master's Degree January 4, 2018 Woman preparing a fuel evaluation in a constant volume combustion vessel Drew Cameron, Research Participant Program Intern, prepares a test for
Lynch syndrome in the 21st century: clinical perspectives.
Tiwari, A K; Roy, H K; Lynch, H T
2016-03-01
Lynch syndrome (LS) is the most common of all inherited cancer syndromes, associated with substantially elevated risks for colonic and extracolonic malignancies, earlier onset and high rates of multiple primary cancers. At the genetic level, it is caused by a defective mismatch repair (MMR) system due to presence of germline defects in at least one of the MMR genes- MLH1, MSH2, MSH6, PMS2 or EPCAM. An impaired MMR function during replication introduces infidelity in DNA sequence and leads to ubiquitous mutations at simple repetitive sequences (microsatellites), causing microsatellite instability (MSI). Although previously, clinicopathological criteria such as Amsterdam I/II and Revised Bethesda Guidelines were commonly used to identify suspected LS mutation carriers, there has been a recent push towards universally testing, especially in case of colorectal cancers (CRCs), through immunohistochemistry for expression of MMR proteins or through molecular tests (polymerase chain reaction, PCR) for MSI, in order to identify LS mutation carriers and subject them to genetic testing to ascertain the specific gene implicated. In this review, we have discussed the latest diagnostic strategies and the current screening and treatment guidelines for colonic and extracolonic cancers in clinically affected and at-risk individuals for LS. © The Author 2015. Published by Oxford University Press on behalf of the Association of Physicians. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Effects of Run-Up Velocity on Performance, Kinematics, and Energy Exchanges in The Pole Vault
Linthorne, Nicholas P.; Weetman, A. H. Gemma
2012-01-01
This study examined the effect of run-up velocity on the peak height achieved by the athlete in the pole vault and on the corresponding changes in the athlete's kinematics and energy exchanges. Seventeen jumps by an experienced male pole vaulter were video recorded in the sagittal plane and a wide range of run-up velocities (4.5-8.5 m/s) was obtained by setting the length of the athlete's run-up (2-16 steps). A selection of performance variables, kinematic variables, energy variables, and pole variables were calculated from the digitized video data. We found that the athlete's peak height increased linearly at a rate of 0.54 m per 1 m/s increase in run-up velocity and this increase was achieved through a combination of a greater grip height and a greater push height. At the athlete's competition run-up velocity (8.4 m/s) about one third of the rate of increase in peak height arose from an increase in grip height and about two thirds arose from an increase in push height. Across the range of run-up velocities examined here the athlete always performed the basic actions of running, planting, jumping, and inverting on the pole. However, he made minor systematic changes to his jumping kinematics, vaulting kinematics, and selection of pole characteristics as the run-up velocity increased. The increase in run-up velocity and changes in the athlete's vaulting kinematics resulted in substantial changes to the magnitudes of the energy exchanges during the vault. A faster run-up produced a greater loss of energy during the take-off, but this loss was not sufficient to negate the increase in run-up velocity and the increase in work done by the athlete during the pole support phase. The athlete therefore always had a net energy gain during the vault. However, the magnitude of this gain decreased slightly as run-up velocity increased. Key pointsIn the pole vault the optimum technique is to run-up as fast as possible.The athlete's vault height increases at a rate of about 0.5 m per 1 m/s increase in run-up velocity.The increase in vault height is achieved through a greater grip height and a greater push height. At the athlete's competition run-up velocity about one third of the rate of increase in vault height arises from an increase in grip height and two thirds arises from an increase in push height.The athlete has a net energy gain during the vault. A faster run-up velocity produces a greater loss of energy during the take-off but this loss of energy is not sufficient to negate the increase in run-up velocity and the increase in the work done by the athlete during the pole support phase. PMID:24149197
[Animal drugs quality status and reason analysis].
Ding, Qing; Qiu, Ya-jing; Fang, Ke-hui; Hu, Hao-bin; Wu, Yue
2015-11-01
In order to reaction the quality present situation, problems on the current quality of animal sources of drugs are summed up by using test data analysis, literature search and marketing research. This paper can also help the improvement of the quality management, the revision of the relevant department policy system and the improvement of standards.
Tuuli, Methodius G; Frey, Heather A; Odibo, Anthony O; Macones, George A; Cahill, Alison G
2012-09-01
To estimate whether immediate or delayed pushing in the second stage of labor optimizes spontaneous vaginal delivery and other perinatal outcomes. We searched electronic databases MEDLINE and CINHAL through August 2011 without restrictions. The search terms used were MeSH headings, text words, and word variations of the words or phrases labor, laboring down, passive descent, passive second stage, physiologic second stage, spontaneous pushing, pushing, or bearing down. We searched for randomized controlled trials comparing immediate with delayed pushing in the second stage of labor. The primary outcome was spontaneous vaginal delivery. Secondary outcomes were instrumental delivery, cesarean delivery, duration of the second stage, duration of active pushing, and other maternal and neonatal outcomes. Heterogeneity was assessed using the Q test and I2. Pooled relative risks (RRs) and weighted mean differences were calculated using random-effects models. Twelve randomized controlled trials (1,584 immediate and 1,531 delayed pushing) met inclusion criteria. Overall, delayed pushing was associated with an increased rate of spontaneous vaginal delivery compared with immediate pushing (61.5% compared with 56.9%, pooled RR 1.09, 95% confidence interval [CI] 1.03-1.15). This increase was smaller and not statistically significant among high-quality studies (59.0% compared with 54.9%, pooled RR 1.07, 95% CI 0.98-1.26) but larger and statistically significant in lower-quality studies (81.0% compared with 71.0%%, pooled RR 1.13, 95% CI 1.02-1.24). Operative vaginal delivery rates were high in most studies and not significantly different between the two groups (33.7% compared with 37.4%, pooled RR 0.89, 95% CI 0.76-1.06). Delayed pushing was associated with prolongation of the second stage (weighted mean difference 56.92 minutes, 95% CI 42.19-71.64) and shortened duration of active pushing (weighted mean difference -21.98 minutes, 95% CI -31.29 to -12.68). Studies to date suggest there are few clinical differences in outcomes with immediate compared with delayed pushing in the second stage of labor, especially when high-quality studies are pooled. Effects on maternal and neonatal outcomes remain uncertain.
Fusion PIC code performance analysis on the Cori KNL system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koskela, Tuomas S.; Deslippe, Jack; Friesen, Brian
We study the attainable performance of Particle-In-Cell codes on the Cori KNL system by analyzing a miniature particle push application based on the fusion PIC code XGC1. We start from the most basic building blocks of a PIC code and build up the complexity to identify the kernels that cost the most in performance and focus optimization efforts there. Particle push kernels operate at high AI and are not likely to be memory bandwidth or even cache bandwidth bound on KNL. Therefore, we see only minor benefits from the high bandwidth memory available on KNL, and achieving good vectorization ismore » shown to be the most beneficial optimization path with theoretical yield of up to 8x speedup on KNL. In practice we are able to obtain up to a 4x gain from vectorization due to limitations set by the data layout and memory latency.« less
Barber, F Alan; Bava, Eric D; Spenciner, David B; Piccirillo, Justin
2013-06-01
The purpose of this study was to assess the mechanical performance of biocomposite knotless lateral row anchors based on both anchor design and the direction of pull. Two lateral row greater tuberosity insertion sites (anterior and posterior) were identified in matched pairs of fresh-frozen human cadaveric shoulders DEXA (dual energy X-ray absorptiometry) scanned to verify comparability. The humeri were stripped of all soft tissue and 3 different biocomposite knotless lateral row anchors: HEALIX Knotless BR (DePuy Mitek, Raynham MA), BioComposite PushLock (Arthrex, Naples, FL), and Bio-SwiveLock (Arthrex). Fifty-two anchors were distributed among the insertion locations and tested them with either an anatomic or axial pull. A fixed-gauge loop (15 mm) of 2 high-strength sutures from each anchor was created. After a 10-Nm preload, anchors were cycled from 10 to 45 Nm at 0.5 Hz for 200 cycles and tested to failure at 4.23 mm/second. The load to reach 3 mm and 5 mm displacement, ultimate failure load, displacement at ultimate failure, and failure mode were recorded. Threaded anchors (Bio-SwiveLock, P = .03; HEALIX Knotless, P = .014) showed less displacement with anatomic testing than did the nonthreaded anchor (BioComposite PushLock), and the HEALIX Knotless showed less overall displacement than did the other 2 anchors. The Bio-SwiveLock exhibited greater failure loads than did the other 2 anchors (P < .05). Comparison of axial and anatomic loading showed no maximum load differences for all anchors as a whole (P = .1084). Yet, anatomic pulling produced higher failure loads than did axial pulling for the Bio-SwiveLock but not for the BioComposite PushLock or the HEALIX Knotless. The nonthreaded anchor (BioComposite PushLock) displayed lower failure loads than did both threaded anchors with axial pulling. Threaded biocomposite anchors (HEALIX Knotless BR and Bio-SwiveLock) show less anatomic loading displacement and higher axial failure loads than do the nonthreaded (BioComposite PushLock) anchor. The HEALIX Knotless BR anchor showed less displacement than did the BioComposite PushLock and Bio-SwiveLock anchors. Neither axial nor anatomic loading had an effect on overall anchor displacement. Because of the strength profiles exhibited, this study supports the use of biocomposite anchors, which have definite advantages over polyetheretherketone (PEEK) and metal products. However, the nonthreaded BioComposite PushLock anchor cannot be recommended. Copyright © 2013 Arthroscopy Association of North America. All rights reserved.
SCPS-TP, TCP, and Rate-Based Protocol Evaluation. Revised
NASA Technical Reports Server (NTRS)
Tran, Diepchi T.; Lawas-Grodek, Frances J.; Dimond, Robert P.; Ivancic, William D.
2005-01-01
Tests were performed at Glenn Research Center to compare the performance of the Space Communications Protocol Standard Transport Protocol (SCPS TP, otherwise known as "TCP Tranquility") relative to other variants of TCP and to determine the implementation maturity level of these protocols, particularly for higher speeds. The testing was performed over reasonably high data rates of up to 100 Mbps with delays that are characteristic of near-planetary environments. The tests were run for a fixed packet size, but for variously errored environments. This report documents the testing performed to date.
Jones, Margaret T; Martin, Joel R; Jagim, Andrew R; Oliver, Jonathan M
2017-05-01
Jones, MT, Martin, JR, Jagim, AR, and Oliver, JM. Effect of direct whole-body vibration on upper-body muscular power in recreational, resistance-trained men. J Strength Cond Res 31(5): 1371-1377, 2017-To determine the acute effect of whole-body vibration (WBV) on upper-body power, 15 men (mean ± SD; age 21.5 ± 2.3 years; height 173.1 ± 6.5 cm; and weight 77.2 ± 13.8 kg) with ≥1-year resistance training experience and a bench press (BP): body mass ratio ≥1.25 participated in a repeated-measures crossover design. Session 1 included body composition ([Bod Pod] 15.76 ± 6.7% body fat), 3 repetition maximum BP, and familiarization with: seated medicine ball throw (SMBT), plyometric push-up (PPU) on a force plate, and vertical WBV platform. Sessions 2-5 were randomly ordered across condition and test, separated by 24 hours, and consisted of a warm-up followed by 4 × 30-second push-up holds (2 × elbows at 90° and 2 × arms extended) performed on the vibration platform with WBV (frequency: 30 Hz, amplitude: 2-4 mm, 1:1 work: relief ratio) or no WBV. Seated medicine ball throw and PPU were tested immediately, 1, 5, and 10 minutes post. Standardized magnitude-based inferences were used to define outcomes. A likely positive effect of WBV was observed for SMBT at 10 minutes post. A likely negative effect of WBV resulted at 1 minute in time-to-peak force. A possibly positive effect was observed 10 minutes post. A possibly negative effect was observed 10 minutes post for peak power, and a likely negative effect of WBV was observed on time-to-peak power immediate post. Incorporating a 10-minute rest period is recommended when implementing power exercises after upper-body static-hold exercises during WBV exposure.
Batailler, C; Bonin, N; M Wettstein; Nogier, A; Martres, S; Ollier, E; May, O; Lustig, S
2017-12-01
Impingement of the ilio-psoas tendon on the acetabular component is a cause of pain after total hip arthroplasty (THA). Studies of cup revision for ilio-psoas impingement (IPI) are scarce and limited in size. We therefore conducted a large multicentre retrospective study with the following objectives: to assess the effectiveness of cup replacement in resolving the impingement syndrome, to determine the frequency and nature of complications after cup revision for IPI, and to identify pre-operative factors associated with good outcomes of cup revision for IPI. Cup revision is effective in resolving the pain due to IPI in selected patients. This retrospective multicentre study included 46 patients who underwent cup revision because of IPI. Before the revision, 38 (83%) patients had prominence of the anterior cup rim (mean, 9.9±4.5mm (range, 2-22mm) by radiography and 35 (76%) had cup malposition (anteversion<10° and/or inclination>50°). Mean follow-up was 21months (range, 6months to 6 years) and no patient was lost to follow-up. Outcomes at last follow-up were assessed based on the Oxford Hip Score (OHS), patient satisfaction index, complications, and revisions. At last follow-up, 39 (85%) patients were satisfied with the revision procedure, a significant improvement versus baseline was noted in the OHS (mean, 43±6; range, 25-48; P<0.001), and 41 patients were free of pain during hip flexion (P<0.001 versus baseline). Complications occurred in 3 (6.5%) patients, but only one complication was severe (deep infection). Recurrent groin pain was reported by 4 (8.7%) patients at last follow-up. None of the factors studied predicted the outcome of revision surgery. Cup revision for IPI after THA is effective in relieving the groin pain in 80% of patients with anterior cup rim prominence and/or cup malposition. However, complications can occur. Tenotomy may be preferable when the diagnosis is in doubt and/or cup position is acceptable. IV, retrospective observational study. Published by Elsevier Masson SAS.
Physical Fitness in Young Adults Born Preterm.
Tikanmäki, Marjaana; Tammelin, Tuija; Sipola-Leppänen, Marika; Kaseva, Nina; Matinolli, Hanna-Maria; Miettola, Satu; Eriksson, Johan G; Järvelin, Marjo-Riitta; Vääräsmäki, Marja; Kajantie, Eero
2016-01-01
Young adults born preterm have higher levels of cardiometabolic risk factors than their term-born peers. Muscular and cardiorespiratory fitness have important cardiometabolic and other health benefits. We assessed muscular, cardiorespiratory, and self-rated fitness in preterm-born young adults. We studied unimpaired participants of the ESTER (Ennenaikainen syntymä ja aikuisiän terveys [Preterm Birth and Early-Life Programming of Adult Health and Disease]) birth cohort study at age 23.3 (SD: 1.2) years: 139 born early preterm (EPT; <34 weeks), 247 late preterm (LPT; 34-36 weeks), and 352 at term (control group). We measured muscular fitness with the number of modified push-ups performed in 40 seconds and maximal handgrip strength of the dominant hand, cardiovascular fitness with heart rate at the end of a 4-minute step test, and self-rated fitness. Data were analyzed with linear regression. Young adults born EPT (-0.8; 95% confidence interval: -1.5 to -0.1; adjusted for gender, age, and source cohort) and LPT (-0.8; -1.4 to -0.3) performed fewer modified push-ups than controls. Handgrip strength was 23.8 (0.9-46.8) N lower in EPT participants. Cardiorespiratory fitness, measured by submaximal step test, was similar. On a self-rated fitness scale (1-5), the EPT adults reported 0.2 (0.0-0.4) lower scores than controls. After adjustment for early-life confounders, the results remained. They attenuated after further adjustment for mediating factors. Young adults born EPT and LPT had lower muscular fitness than controls, which may predispose them to cardiometabolic and other chronic diseases. Adults born EPT also perceived themselves as less fit than controls. Copyright © 2016 by the American Academy of Pediatrics.
Hubbell, Joel M.; Sisson, James B.
2005-07-26
A method of inserting a tensiometer into a sample, comprises providing a drive probe configured to be engaged by direct push equipment; supporting a porous member from the drive probe; and driving the drive probe into the sample using a cone penetrometer. A tensiometer comprises a drive probe configured to be engaged by direct push equipment or a cone penetrometer; a porous member supported by the drive probe; and a pressure sensor in pressure sensing relation to the porous member.
Evaluation of a Powered Ankle-Foot Prosthesis during Slope Ascent Gait
2016-01-01
Passive prosthetic feet lack active plantarflexion and push-off power resulting in gait deviations and compensations by individuals with transtibial amputation (TTA) during slope ascent. We sought to determine the effect of active ankle plantarflexion and push-off power provided by a powered prosthetic ankle-foot (PWR) on lower extremity compensations in individuals with unilateral TTA as they walked up a slope. We hypothesized that increased ankle plantarflexion and push-off power would reduce compensations commonly observed with a passive, energy-storing-returning prosthetic ankle-foot (ESR). We compared the temporal spatial, kinematic, and kinetic measures of ten individuals with TTA (age: 30.2 ± 5.3 yrs) to matched abled-bodied (AB) individuals during 5° slope ascent. The TTA group walked with an ESR and separately with a PWR. The PWR produced significantly greater prosthetic ankle plantarflexion and push-off power generation compared to an ESR and more closely matched AB values. The PWR functioned similar to a passive ESR device when transitioning onto the prosthetic limb due to limited prosthetic dorsiflexion, which resulted in similar deviations and compensations. In contrast, when transitioning off the prosthetic limb, increased ankle plantarflexion and push-off power provided by the PWR contributed to decreased intact limb knee extensor power production, lessening demand on the intact limb knee. PMID:27977681
Evaluation of a Powered Ankle-Foot Prosthesis during Slope Ascent Gait.
Rábago, Christopher A; Aldridge Whitehead, Jennifer; Wilken, Jason M
2016-01-01
Passive prosthetic feet lack active plantarflexion and push-off power resulting in gait deviations and compensations by individuals with transtibial amputation (TTA) during slope ascent. We sought to determine the effect of active ankle plantarflexion and push-off power provided by a powered prosthetic ankle-foot (PWR) on lower extremity compensations in individuals with unilateral TTA as they walked up a slope. We hypothesized that increased ankle plantarflexion and push-off power would reduce compensations commonly observed with a passive, energy-storing-returning prosthetic ankle-foot (ESR). We compared the temporal spatial, kinematic, and kinetic measures of ten individuals with TTA (age: 30.2 ± 5.3 yrs) to matched abled-bodied (AB) individuals during 5° slope ascent. The TTA group walked with an ESR and separately with a PWR. The PWR produced significantly greater prosthetic ankle plantarflexion and push-off power generation compared to an ESR and more closely matched AB values. The PWR functioned similar to a passive ESR device when transitioning onto the prosthetic limb due to limited prosthetic dorsiflexion, which resulted in similar deviations and compensations. In contrast, when transitioning off the prosthetic limb, increased ankle plantarflexion and push-off power provided by the PWR contributed to decreased intact limb knee extensor power production, lessening demand on the intact limb knee.
ERIC Educational Resources Information Center
Yoon, So Yoon
2011-01-01
Working under classical test theory (CTT) and item response theory (IRT) frameworks, this study investigated psychometric properties of the Revised Purdue Spatial Visualization Tests: Visualization of Rotations (Revised PSVT:R). The original version, the PSVT:R was designed by Guay (1976) to measure spatial visualization ability in…
The Impact of Pushed Output on Accuracy and Fluency of Iranian EFL Learners' Speaking
ERIC Educational Resources Information Center
Sadeghi Beniss, Aram Reza; Edalati Bazzaz, Vahid
2014-01-01
The current study attempted to establish baseline quantitative data on the impacts of pushed output on two components of speaking (i.e., accuracy and fluency). To achieve this purpose, 30 female EFL learners were selected from a whole population pool of 50 based on the standard test of IELTS interview and were randomly assigned into an…
Development of testing machine for tunnel inspection using multi-rotor UAV
NASA Astrophysics Data System (ADS)
Iwamoto, Tatsuya; Enaka, Tomoya; Tada, Keijirou
2017-05-01
Many concrete structures are deteriorating to dangerous levels throughout Japan. These concrete structures need to be inspected regularly to be sure that they are safe enough to be used. The inspection method for these concrete structures is typically the impact acoustic method. In the impact acoustic method, the worker taps the surface of the concrete with a hammer. Thus, it is necessary to set up scaffolding to access tunnel walls for inspection. Alternatively, aerial work platforms can be used. However, setting up scaffolding and aerial work platforms is not economical with regard to time or money. Therefore, we developed a testing machine using a multirotor UAV for tunnel inspection. This test machine flies by a plurality of rotors, and it is pushed along a concrete wall and moved by using rubber crawlers. The impact acoustic method is used in this testing machine. This testing machine has a hammer to make an impact, and a microphone to acquire the impact sound. The impact sound is converted into an electrical signal and is wirelessly transmitted to the computer. At the same time, the position of the testing machine is measured by image processing using a camera. The weight and dimensions of the testing machine are approximately 1.25 kg and 500 mm by 500 mm by 250 mm, respectively.
Superheating in coated niobium
NASA Astrophysics Data System (ADS)
Junginger, T.; Wasserman, W.; Laxdal, R. E.
2017-12-01
Using muon spin rotation it is shown that the field of first flux penetration {H}{entry} in Nb is enhanced by about 30% if coated with an overlayer of Nb3Sn or MgB2. This is consistent with an increase from the lower critical magnetic field {H}{{c}1} up to the superheating field {H}{sh} of the Nb substrate. In the experiments presented here coatings of Nb3Sn and MgB2 with a thickness between 50 and 2000 nm have been tested. {H}{entry} does not depend on material or thickness. This suggests that the energy barrier at the boundary between the two materials prevents flux entry up to {H}{sh} of the substrate. A mechanism consistent with these findings is that the proximity effect recovers the stability of the energy barrier for flux penetration, which is suppressed by defects for uncoated samples. Additionally, a low temperature baked Nb sample has been tested. Here a 6% increase of {H}{entry} was found, also pushing {H}{entry} beyond {H}{{c}1}.
A passive exoskeleton can push your life up: application on multiple sclerosis patients.
Di Russo, Francesco; Berchicci, Marika; Perri, Rinaldo Livio; Ripani, Francesca Romana; Ripani, Maurizio
2013-01-01
In the present study, we report the benefits of a passive and fully articulated exoskeleton on multiple sclerosis patients by means of behavioral and electrophysiological measures, paying particular attention to the prefrontal cortex activity. Multiple sclerosis is a neurological condition characterized by lesions of the myelin sheaths that encapsulate the neurons of the brain, spine and optic nerve, and it causes transient or progressive symptoms and impairments in gait and posture. Up to 50% of multiple sclerosis patients require walking aids and 10% are wheelchair-bound 15 years following the initial diagnosis. We tested the ability of a new orthosis, the "Human Body Posturizer", designed to improve the structural and functional symmetry of the body through proprioception, in multiple sclerosis patients. We observed that a single Human Body Posturizer application improved mobility, ambulation and response accuracy, in all of the tested patients. Most importantly, we associated these clinical observations and behavioral effects to changes in brain activity, particularly in the prefrontal cortex.
Rewriting age to overcome misaligned age and gender norms in later life.
Morelock, Jeremiah C; Stokes, Jeffrey E; Moorman, Sara M
2017-01-01
In this paper we suggest that older adults undergo a misalignment between societal age norms and personal lived experience, and attempt reconciliation through discursive strategies: They rewrite how they frame chronological age as well as their subjective relations to it. Using a sample of 4041 midlife and older adults from the 2004-2006 wave of the National Survey of Midlife Development in the United States (MIDUS II), we explore associations of age and gender with subjective age and at what age respondents felt people enter later life. Our results confirm that as men and women age, they push up the age at which they think people enter later life, and slow down subjective aging (there is a growing gap between subjective and chronological age). Relations between a person's age and at what age they think people enter later life were stronger for men than for women. For every year they get older get older, men push up when they think people enter later life by 0.24years, women by 0.16years. Age norms surrounding the transition to later life may be more prominent for men than for women, and the difference in their tendencies to push up when they mark entry into later life may be a reflection of this greater prominence. Copyright © 2016 Elsevier Inc. All rights reserved.
... the solution bottle. On first use, insert the plastic tube with stopper tightly into the bottle until ... fully pushed in, into the opening in the plastic tube. Draw up the amount of solution your ...
Boehm Test of Basic Concepts-Revised. Review.
ERIC Educational Resources Information Center
Padula, Janice
1988-01-01
The manual for the Boehm Test of Basic Concepts-Revised (1986) is reviewed. The test measures a child's knowledge of relational concepts. The revised version, eliminating some imperfections of the original, will continue to be a useful test of verbal concept acquisition. Cautions necessary while using the test are discussed. (SLD)
Effect of different root canal obturating materials on push-out bond strength of a fiber dowel.
Aggarwal, Vivek; Singla, Mamta; Miglani, Sanjay; Kohli, Sarita
2012-07-01
During dowel space preparation, the instrumentation forms a thick smear layer along with sealer-occluded dentinal tubules. The purpose of this study was to evaluate the effect of different obturating materials on push-out bond strength of a fiber dowel. Fifty human uniradicular teeth were decoronated and prepared using the step-back technique. The specimens were divided into five groups on the basis of obturating materials: group I received no obturation; group II (ZOE) gutta-percha and zinc oxide eugenol sealer; group III (ZOAH) gutta-percha and AH plus sealer; group IV (GF) GuttaFlow; and group V (RE) with Resilon Epiphany system. Dowel spaces were made with manufacturer's provided drills, and a fiber dowel was luted. Horizontal slices were obtained from the middle third, and push-out bond strength (S) was evaluated. Statistical analysis was carried out using one-way ANOVA and post hoc Tukey's test. The push-out bond strength values in the control group, ZOE, ZOAH, GF, and RE were 9.303 ± 0.565 MPa, 8.859 ± 0.539 MPa, 8.356 ± 0.618 MPa, 9.635 ± 0.435 MPa, and 8.572 ± 0.256 MPa, respectively. There was no statistically significant difference between the S values of all the groups (p > 0.05). There was no effect of different tested obturating materials on the push-out bond strength of fiber dowels; however, further studies should be conducted. © 2012 by the American College of Prosthodontists.
NASA Astrophysics Data System (ADS)
Pombo, S. A.; Schroth, M. H.; Pelz, O.; Zeyer, J.
2001-12-01
Stable isotope analysis of phospholipid-derived fatty acids (PLFA) is a novel tool to trace assimilation of organic carbon in microbial communities. The 13C-labeling of biomarker fatty acids allows the identification of specific microbial populations involved in the metabolism of particular substrates, supplemented in 13C-labeled form. The goal of this study was to investigate the feasibility of 13C-labeling of PLFA and produced dissolved inorganic carbon (DIC) in a petroleum hydrocarbon (PHC)-contaminated aquifer during an in-situ experiment. To this end, we performed a single-well "push-pull" test in a monitoring well located in the denitrifying zone of a PHC-contaminated aquifer in Studen, Switzerland. During the experiment, we injected 500 L of site groundwater that was amended with 13C-labeled acetate (50% [2-13C]) and nitrate as reactants, and bromide as conservative tracer. Following the injection, we extracted a total of 1000 L of test solution/groundwater mixture after 4, 23 and 46 h from the same location. Concentrations of anions were measured in samples collected during the extraction. From these data, we computed first order rate coefficients for consumption of acetate (0.70 +/- 0.05 1/d) and nitrate (0.63 +/- 0.08 1/d). In addition, we extracted and identified PLFA, and measured \\delta13C values of PLFA and DIC. After only 4 h of incubation, we detected 13C-enrichment of certain PLFA in suspended biomass of extracted groundwater. After 46 h, we measured enrichments of up to 5000 per mil in certain PLFA (e.g. 16:1ω 7c), and up to 1500 per mil in the produced DIC. Our results demonstrate the feasibility of in-situ 13C-labeling of PLFA and DIC using push-pull tests to determine microbial activities in-situ in a natural ecosystem.
Group Discussion Topics. Revised Edition.
ERIC Educational Resources Information Center
Area Education Agency 7, Cedar Falls, IA.
A collection of group disussion topics, developed and field-tested by a group of Iowa teachers, is presented in this guide. Twenty-eight topics for K-6 students, 24 topics for K-12 students, and 7 topics for students in grades 7-12 are included. Warm-up activities are given for introducing some of the topics, and lists of questions to provoke…
Sit-ups and Push-ups Only--Are We Heading for Muscular Imbalance?
ERIC Educational Resources Information Center
Bennett, Jane G.; Murphy, Debra J.
1995-01-01
Physical education teachers should incorporate the concept of muscular balance into their daily curricula and select activities that work the muscles as they are used in everyday activities. The article focuses on maintaining normal strength between the anterior and posterior trunk muscles, detailing appropriate exercises. (SM)
NASA Astrophysics Data System (ADS)
Yonekawa, M.; Ishii, T.; Ohmi, M.; Takada, F.; Hoshiya, T.; Niimi, M.; Ioka, I.; Miwa, Y.; Tsuji, H.
2002-12-01
In order to investigate effects of neutron irradiation on fatigue properties of nuclear materials, a remote-controlled high temperature fatigue test machine was developed at the hot laboratory of the Japan Materials Testing Reactor (JMTR) in the Japan Atomic Energy Research Institute (JAERI). A small-sized fatigue specimen having double blades to measure strain with a laser extensometer was designed for this machine. A strain amplitude in fatigue tests of a completely reversed push-pull type using a triangular wave was controlled with an accuracy of ±3% of the total strain range during test. Low cycle fatigue tests of type 304 stainless steel irradiated in JMTR at 823 K up to a fast neutron fluence of 1×10 25 n/m 2 ( E>1 MeV) were performed in total strain ranges of 0.7-1.4% at 823 K using the designed small-sized specimens.
Double-push skating versus V2 and V1 skating on uphill terrain in cross-country skiing.
Stöggl, Thomas; Kampel, Wolfgang; Müller, Erich; Lindinger, Stefan
2010-01-01
The aims of the study were a) to compare the double-push skating technique with the V2 and the V1 skating techniques on an uphill terrain by a kinematic and kinetic analysis, b) to provide kinetic and kinematic data of the V1 technique at maximal skiing speeds, and c) to test the hypotheses that the double-push skating technique is faster compared with the V2 and the V1 skating techniques. Six elite skiers performed maximum speed sprints over a 60-m uphill section (7 degrees -10 degrees) using the double-push, the V2, and the V1 techniques. Pole and plantar forces and cycle characteristics were analyzed. The double-push skating technique was approximately 4.3% faster (P < 0.05) compared with the V2 skating technique and equally fast compared with the V1 skating technique. The double-push and the V2 techniques demonstrated longer cycle lengths, lower cycle rates (both P < 0.05), and equal poling frequencies and pole forces compared with the V1 technique. Cycle length, peak foot force, and knee extension ranges of motion and velocities were higher in the double-push technique compared with the V2 technique (all P values <0.05). Center of pressure was located more laterally in the double-push technique compared with the other two techniques (P < 0.05). All measured skiing speeds were drastically higher compared with former studies. The higher skiing speeds of the V1 and the double-push techniques compared with the V2 technique stress the mechanical advantage of those techniques on uphill terrain. Because of larger cycle lengths, lower cycle rate, longer recovery times, and equal poling frequency, the double-push technique might be seen as more economic on steep uphills compared with the V1 technique. From a tactical point of view compared with the V1 technique, the double-push technique needs less space due to less lateral displacement, and no technique transitions are necessary when entering and leaving an uphill section.
On Parallel Push-Relabel based Algorithms for Bipartite Maximum Matching
DOE Office of Scientific and Technical Information (OSTI.GOV)
Langguth, Johannes; Azad, Md Ariful; Halappanavar, Mahantesh
2014-07-01
We study multithreaded push-relabel based algorithms for computing maximum cardinality matching in bipartite graphs. Matching is a fundamental combinatorial (graph) problem with applications in a wide variety of problems in science and engineering. We are motivated by its use in the context of sparse linear solvers for computing maximum transversal of a matrix. We implement and test our algorithms on several multi-socket multicore systems and compare their performance to state-of-the-art augmenting path-based serial and parallel algorithms using a testset comprised of a wide range of real-world instances. Building on several heuristics for enhancing performance, we demonstrate good scaling for themore » parallel push-relabel algorithm. We show that it is comparable to the best augmenting path-based algorithms for bipartite matching. To the best of our knowledge, this is the first extensive study of multithreaded push-relabel based algorithms. In addition to a direct impact on the applications using matching, the proposed algorithmic techniques can be extended to preflow-push based algorithms for computing maximum flow in graphs.« less
Retro Rocket Motor Self-Penetrating Scheme for Heat Shield Exhaust Ports
NASA Technical Reports Server (NTRS)
Marrese-Reading, Colleen; St.Vaughn, Josh; Zell, Peter; Hamm, Ken; Corliss, Jim; Gayle, Steve; Pain, Rob; Rooney, Dan; Ramos, Amadi; Lewis, Doug;
2009-01-01
A preliminary scheme was developed for base-mounted solid-propellant retro rocket motors to self-penetrate the Orion Crew Module heat shield for configurations with the heat shield retained during landings on Earth. In this system the motors propel impactors into structural push plates, which in turn push through the heat shield ablator material. The push plates are sized such that the remaining port in the ablator material is large enough to provide adequate flow area for the motor exhaust plume. The push plate thickness is sized to assure structural integrity behind the ablative thermal protection material. The concept feasibility was demonstrated and the performance was characterized using a gas gun to launch representative impactors into heat shield targets with push plates. The tests were conducted using targets equipped with Fiberform(R) and PICA as the heat shield ablator material layer. The PICA penetration event times were estimated to be under 30 ms from the start of motor ignition. The mass of the system (not including motors) was estimated to be less than 2.3 kg (5 lbs) per motor. The configuration and demonstrations are discussed.
Park, Se-yeon; Ahn, Tae-kyung; Eom, Ji-hwan; Youn, Hyun-ji; Kim, In-kwang; Yoo, Won-gyu
2014-01-01
[Purpose] The purpose of this study was to evaluate the effect of the wall slide device on activation of the scapulothoracic musculature. [Subjects] We recruited 15 healthy male subjects. [Methods] The subjects performed the general wall push-up plus (WPUP) and the wall slide with device (WSD) exercises. During the exercises, the muscle activities of the upper and lower trapezius (UT, LT), middle and lower serratus anterior (MSA, LSA), and pectoralis major (PM) were measured. [Results] The normalized muscle activity data of the WSD were significantly higher in UT, MSA and LSA than the WPUP. [Conclusion] Our results suggest that exercise using the WSD can more effectively activate the scapulothoracic musculature than the general WPUP. PMID:25013271
Mirouse, G; Rousseau, R; Casabianca, L; Ettori, M A; Granger, B; Pascal-Moussellard, H; Khiami, F
2016-11-01
The surgical revision rate following anterior cruciate ligament (ACL) surgery is 3% at 2 years and 4% at 5 years. Revision ACL surgery raises the question of the type of graft to be used. The present study assessed return to sports and functional results after revision ACL reconstruction by fascia lata graft. The hypothesis was that fascia lata provides a reliable graft in revision ACL surgery. A single-center retrospective continuous study included 30 sports players with a mean age of 26.8±8 years undergoing surgical revision for iterative ACL tear between 2004 and 2013. Multi-ligament lesions were excluded. Type and level of sports activity were assessed preoperatively, after primary surgery and at end of follow-up. Clinical assessment used subjective IKDC, Lysholm and KOOS scores. At a mean 4.6±1.6 years' follow-up, all patients had resumed sport activity, but only 12 with the same sport at the same level. Median subjective IKDC score increased from 57 [54.3; 58.5] preoperatively to 82 [68.3; 90] at last follow-up, and Lysholm score from 46 [42.3; 51] to 90.5 [80.8; 96.8]; KOOS score at last follow-up was 94.7 [83; 100]. Functional results in revision ACL reconstruction by fascia lata graft were satisfactory, with similar return-to-sports rates as with other techniques. Fascia lata provides a reliable graft in revision ACL surgery. IV, retrospective study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Sapphire reinforced alumina matrix composites
NASA Technical Reports Server (NTRS)
Jaskowiak, Martha H.; Setlock, John A.
1994-01-01
Unidirectionally reinforced A1203 matrix composites have been fabricated by hot pressing. Approximately 30 volume % of either coated or uncoated sapphire fiber was used as reinforcement. Unstabilized ZrO2 was applied as the fiber coating. Composite mechanical behavior was analyzed both after fabrication and after additional heat treatment. The results of composite tensile tests were correlated with fiber-matrix interfacial shear strengths determined from fiber push-out tests. Substantially higher strength and greater fiber pull-out were observed for the coated fiber composites for all processing conditions studied. The coated fiber composites retained up to 95% and 87% of their as-fabricated strength when heat treated at 14000C for 8 or 24 hours, respectively. Electron microscopy analysis of the fracture surfaces revealed extensive fiber pull-out both before and after heat treatment.
Multi-Kilowatt Power Module for High-Power Hall Thrusters
NASA Technical Reports Server (NTRS)
Pinero, Luis R.; Bowers, Glen E.
2005-01-01
Future NASA missions will require high-performance electric propulsion systems. Hall thrusters are being developed at NASA Glenn for high-power, high-specific impulse operation. These thrusters operate at power levels up to 50 kW of power and discharge voltages in excess of 600 V. A parallel effort is being conducted to develop power electronics for these thrusters that push the technology beyond the 5kW state-of-the-art power level. A 10 kW power module was designed to produce an output of 500 V and 20 A from a nominal 100 V input. Resistive load tests revealed efficiencies in excess of 96 percent. Load current share and phase synchronization circuits were designed and tested that will allow connecting multiple modules in parallel to process higher power.
... activities, including your shoulder joint and your shoulder blade Observe your spine and posture as you stand ... band Isometric shoulder exercises Wall push-ups Shoulder blade (scapular) retraction - no tubing Shoulder blade (scapular) retraction - ...
Effect of surface treatment and type of cement on push-out bond strength of zirconium oxide posts.
Almufleh, Balqees S; Aleisa, Khalil I; Morgano, Steven M
2014-10-01
The effect of the surface treatment of zirconium oxide posts on their push-out bond strength is controversial. The purpose of this study was to compare the effects of 2 surface treatments on the bond strength of zirconium oxide posts cemented with different cements and to assess the failure mode. Seventy extracted human teeth were divided into 7 groups (n=10). Custom zirconium oxide posts (Cercon; Degudent) were fabricated for 6 groups. Posts in 3 groups were airborne-particle abraded (A). Posts in the other 3 groups were tribochemical silica coated (T). Three cements were used. Zinc phosphate cement was used to cement the zirconium oxide posts in groups AZ and TZ, RelyX ARC cement was used in groups ARA and TRA, and RelyX Unicem cement was used in groups ARU and TRU. Group C contained custom metal posts cemented with zinc phosphate cement. Specimens were horizontally sectioned into 3 sections and subjected to a push-out test. A mixed model analysis of variance, 1-way ANOVA, and the Tukey multiple comparison tests were used for statistical analysis. The highest push-out bond strength was recorded for Group ARU (21.03 MPa), and the lowest was recorded for Group ARA (7.57 MPa). No significant difference in push-out bond strength was found among the different surface treatments and root regions (P>.05). The type of cement had a significant effect on the push-out bond strength of zirconium oxide posts (P=.049). RelyX Unicem cement recorded (19.57 ±8.83 MPa) significantly higher push-out bond strength compared with zinc phosphate (9.95 ±6.31 MPa) and RelyX ARC cements (9.39 ±5.45 MPa). Adhesive failure at the post-cement interface was recorded for 75% of the posts cemented with zinc phosphate and RelyX ARC cements, while mixed failure was recorded for 75% of the posts cemented with RelyX Unicem cement. The type of cement used resulted in a statistically significant difference in the push-out bond strength of zirconium oxide posts, while both the surface treatment and root region resulted in no statistically significant effect after artificial aging. RelyX Unicem cement had significantly higher push-out bond strength than did zinc phosphate and RelyX ARC cements. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Long-term Follow-up of Revision Osteochondral Allograft Transplantation of the Ankle.
Gaul, Florian; Tírico, Luís E P; McCauley, Julie C; Bugbee, William D
2018-05-01
Osteochondral allograft (OCA) transplantation is a useful alternative for treatment of posttraumatic ankle arthritis in young patients but has a relatively high failure rate and further procedures are often required. The purpose of this study was to evaluate outcomes of patients who underwent revision OCA transplantation of the ankle after failed primary OCA transplantation. Twenty patients underwent revision OCA transplantation of the ankle between 1988 and 2015. Mean age was 44 years, 55% (11 of 20) were female. The mean time from primary to revision OCA was 3.0 ± 1.7 years. All patients had a minimum follow-up of 2 years. Outcomes included the American Academy of Orthopaedic Surgeons Foot and Ankle Module (AAOS-FAM) and questionnaires evaluating pain and satisfaction. Failure of the revision OCA was defined as a conversion to arthroplasty, arthrodesis, or amputation. Ten of 20 ankles required further surgery, of which 30% (6 of 20) were considered OCA revision failures (4 arthrodeses, 1 arthroplasty, and 1 amputation). The mean time to failure was 6.7 (range, 0.6-13.1) years. Survivorship of the revision OCA was 84% at 5 years and 65% at 10 years. The 14 patients with grafts remaining in situ had an average follow-up of 10.3 years; mean AAOS-FAM Core Score was 70.5 (range, 42.3-99). Of the patients who answered the follow-up questions, 4 of 7 reported moderate to severe pain, and 5 of 12 were satisfied with the results of the procedure. Although the results of revision ankle OCA transplantation are not inferior to primary OCA transplantation, the high rates of persistent pain, further surgery, and graft failure suggest that the indications for OCA as a revision procedure should be carefully evaluated, with proper patient selection. Considering the treatment alternatives, revising a failed OCA transplantation can be a useful treatment option, especially for young and active patients who wish to avoid arthrodesis or arthroplasty. Level IV, case series.
Quesada, Roberto E; Caputo, Joshua M; Collins, Steven H
2016-10-03
Amputees using passive ankle-foot prostheses tend to expend more metabolic energy during walking than non-amputees, and reducing this cost has been a central motivation for the development of active ankle-foot prostheses. Increased push-off work at the end of stance has been proposed as a way to reduce metabolic energy use, but the effects of push-off work have not been tested in isolation. In this experiment, participants with unilateral transtibial amputation (N=6) walked on a treadmill at a constant speed while wearing a powered prosthesis emulator. The prosthesis delivered different levels of ankle push-off work across conditions, ranging from the value for passive prostheses to double the value for non-amputee walking, while all other prosthesis mechanics were held constant. Participants completed six acclimation sessions prior to a data collection in which metabolic rate, kinematics, kinetics, muscle activity and user satisfaction were recorded. Metabolic rate was not affected by net prosthesis work rate (p=0.5; R 2 =0.007). Metabolic rate, gait mechanics and muscle activity varied widely across participants, but no participant had lower metabolic rate with higher levels of push-off work. User satisfaction was affected by push-off work (p=0.002), with participants preferring values of ankle push-off slightly higher than in non-amputee walking, possibly indicating other benefits. Restoring or augmenting ankle push-off work is not sufficient to improve energy economy for lower-limb amputees. Additional necessary conditions might include alternate timing or control, individualized tuning, or particular subject characteristics. Copyright © 2016 Elsevier Ltd. All rights reserved.
Choi, Edmond P H; Chin, Weng Yee; Wan, Eric Y F; Lam, Cindy L K
2016-05-01
To examine the internal and external responsiveness of the Pressure Ulcer Scale for Healing (PUSH) tool for assessing the healing progress in acute and chronic wounds. It is important to establish the responsiveness of instruments used in conducting wound care assessments to ensure that they are able to capture changes in wound healing accurately over time. Prospective longitudinal observational study. The key study instrument was the PUSH tool. Internal responsiveness was assessed using paired t-testing and effect size statistics. External responsiveness was assessed using multiple linear regression. All new patients with at least one eligible acute or chronic wound, enrolled in the Nurse and Allied Health Clinic-Wound Care programme between 1 December 2012 - 31 March 2013 were included for analysis (N = 541). Overall, the PUSH tool was able to detect statistically significant changes in wound healing between baseline and discharge. The effect size statistics were large. The internal responsiveness of the PUSH tool was confirmed in patients with a variety of different wound types including venous ulcers, pressure ulcers, neuropathic ulcers, burns and scalds, skin tears, surgical wounds and traumatic wounds. After controlling for age, gender and wound type, subjects in the 'wound improved but not healed' group had a smaller change in PUSH scores than those in the 'wound healed' group. Subjects in the 'wound static or worsened' group had the smallest change in PUSH scores. The external responsiveness was confirmed. The internal and external responsiveness of the PUSH tool confirmed that it can be used to track the healing progress of both acute and chronic wounds. © 2016 The Authors. Journal of Advanced Nursing Published by John Wiley & Sons Ltd.
Te Stroet, M A J; Keurentjes, J C; Rijnen, W H C; Gardeniers, J W M; Verdonschot, N; Slooff, T J J H; Schreurs, B W
2015-10-01
We present the results of 62 consecutive acetabular revisions using impaction bone grafting and a cemented polyethylene acetabular component in 58 patients (13 men and 45 women) after a mean follow-up of 27 years (25 to 30). All patients were prospectively followed. The mean age at revision was 59.2 years (23 to 82). We performed Kaplan-Meier (KM) analysis and also a Competing Risk (CR) analysis because with long-term follow-up, the presence of a competing event (i.e. death) prevents the occurrence of the endpoint of re-revision. A total of 48 patients (52 hips) had died or had been re-revised at final review in March 2011. None of the deaths were related to the surgery. The mean Harris hip score of the ten surviving hips in ten patients was 76 points (45 to 99). The KM survivorship at 25 years for the endpoint 're-revision for any reason' was 58.0% (95% confidence interval (CI) 38 to 73) and for 're-revision for aseptic loosening' 72.1% (95% CI 51 to 85). With the CR analysis we calculated the KM analysis overestimates the failure rate with respectively 74% and 93% for these endpoints. The current study shows that acetabular impaction bone grafting revisions provide good clinical results at over 25 years. ©2015 The British Editorial Society of Bone & Joint Surgery.
Teixeira, Cleonice Silveira; Alfredo, Edson; Thomé, Luis Henrique de Camargo; Gariba-Silva, Ricardo; Silva-Sousa, Yara T. Correa; Sousa, Manoel Damião
2009-01-01
The use of an adequate method for evaluation of the adhesion of root canal filling materials provides more reliable results to allow comparison of the materials and substantiate their clinical choice. The aims of this study were to compare the shear bond strength (SBS) test and push-out test for evaluation of the adhesion of an epoxy-based endodontic sealer (AH Plus) to dentin and guttapercha, and to assess the failure modes on the debonded surfaces by means of scanning electron microscopy (SEM). Three groups were established (n=7): in group 1, root cylinders obtained from human canines were embedded in acrylic resin and had their canals prepared and filled with sealer; in group 2, longitudinal sections of dentin cylinders were embedded in resin with the canal surface smoothed and turned upwards; in group 3, gutta-percha cylinders were embedded in resin. Polyethylene tubes filled with sealer were positioned on the polished surface of the specimens (groups 2 and 3). The push-out test (group 1) and the SBS test (groups 2 and 3) were performed in an Instron universal testing machine running at crosshead speed of 1 mm/min. Means (±SD) in MPa were: G1 (8.8±1.13), G2 (5.9±1.05) and G3 (3.8±0.55). Statistical analysis by ANOVA and Student's t-test (α=0.05) revealed statistically significant differences (p<0.01) among the groups. SEM analysis showed a predominance of adhesive and mixed failures of AH Plus sealer. The tested surface affected significantly the results with the sealer reaching higher bond strength to dentin than to guttapercha with the SBS test. The comparison of the employed methodologies showed that the SBS test produced significantly lower bond strength values than the push-out test, was skilful in determining the adhesion of AH Plus sealer to dentin and gutta-percha, and required specimens that could be easily prepared for SEM, presenting as a viable alternative for further experiments. PMID:19274399
Flat-Cladding Fiber Bragg Grating Sensors for Large Strain Amplitude Fatigue Tests
Feng, Aihen; Chen, Daolun; Li, Cheng; Gu, Xijia
2010-01-01
We have successfully developed a flat-cladding fiber Bragg grating sensor for large cyclic strain amplitude tests of up to ±8,000 με. The increased contact area between the flat-cladding fiber and substrate, together with the application of a new bonding process, has significantly increased the bonding strength. In the push-pull fatigue tests of an aluminum alloy, the plastic strain amplitudes measured by three optical fiber sensors differ only by 0.43% at a cyclic strain amplitude of ±7,000 με and 1.9% at a cyclic strain amplitude of ±8,000 με. We also applied the sensor on an extruded magnesium alloy for evaluating the peculiar asymmetric hysteresis loops. The results obtained were in good agreement with those measured from the extensometer, a further validation of the sensor. PMID:22163621
Biomimetic and bioinspired nanoparticles for targeted drug delivery.
Gagliardi, Mariacristina
2017-03-01
In drug targeting, the urgent need for more effective and less iatrogenic therapies is pushing toward a complete revision of carrier setup. After the era of 'articles used as homing systems', novel prototypes are now emerging. Newly conceived carriers are endowed with better biocompatibility, biodistribution and targeting properties. The biomimetic approach bestows such improved functional properties. Exploiting biological molecules, organisms and cells, or taking inspiration from them, drug vector performances are now rapidly progressing toward the perfect carrier. Following this direction, researchers have refined carrier properties, achieving significant results. The present review summarizes recent advances in biomimetic and bioinspired drug vectors, derived from biologicals or obtained by processing synthetic materials with a biomimetic approach.
NASA Technical Reports Server (NTRS)
Kottapalli, Sesi; Leyland, Jane
1991-01-01
The effects of open loop higher harmonic control (HHC) on rotor hub loads, performance, and push rod loads of a Sikorsky S-76 helicopter rotor at high airspeeds (up to 200 knots) and moderate lift (10,000 lbs) were studied analytically. The analysis was performed as part of a wind tunnel pre-test prediction and preparation procedure, as well as to provide analytical results for post-test correlation efforts. The test associated with this study is to be concluded in the 40- by 80-Foot Wind Tunnel of the National Full-Scale Aerodynamics Complex (NFAC) at the NASA Ames Research Center. The results from this analytical study show that benefits from HHC can be achieved at high airspeeds. These results clear the way for conducting (with the requirement of safe pushrod loads) an open loop HHC test a high airspeeds in the 40- by 80-Foot Wind Tunnel using an S-76 rotor as the test article.
Total knee replacement with retention of both cruciate ligaments: a 22-year follow-up study.
Sabouret, P; Lavoie, F; Cloutier, J-M
2013-07-01
We report on the long-term results of 163 bicruciate-retaining Hermes 2C total knee replacements in 130 patients at a mean follow-up of 22.4 years (20.3 to 23.5). Even when the anterior cruciate ligament had a partially degenerative appearance it was preserved as long as the knee had a normal anterior drawer and Lachman's test pre-operatively. The description and surgical technique of this minimally constrained prosthesis were published in 1983 and the ten-year clinical results in 1999. A total of 12% of the knees (20 of 163) in this study were revised because of wear of the polyethylene tibial insert. Excellent stability was achieved and the incidence of aseptic component loosening was 4.3% (seven of 163). The survival rate using revision for any reason as the endpoint was 82% (95% confidence interval 76.2 to 88.0). Although this series included a relatively small number of replacements, it demonstrated that the anterior cruciate ligament, even when partially degenerated at the time of TKR, remained functional and provided adequate stability at a long-term follow-up.
Effect of wheelchair design on wheeled mobility and propulsion efficiency in less-resourced settings
2017-01-01
Background Wheelchair research includes both qualitative and quantitative approaches, primarily focuses on functionality and skill performance and is often limited to short testing periods. This is the first study to use the combination of a performance test (i.e. wheelchair propulsion test) and a multiple-day mobility assessment to evaluate wheelchair designs in rural areas of a developing country. Objectives Test the feasibility of using wheel-mounted accelerometers to document bouts of wheeled mobility data in rural settings and use these data to compare how patients respond to different wheelchair designs. Methods A quasi-experimental, pre- and post-test design was used to test the differences between locally manufactured wheelchairs (push rim and tricycle) and an imported intervention product (dual-lever propulsion wheelchair). A one-way repeated measures analysis of variance was used to interpret propulsion and wheeled mobility data. Results There were no statistical differences in bouts of mobility between the locally manufactured and intervention product, which was explained by high amounts of variability within the data. With regard to the propulsion test, push rim users were significantly more efficient when using the intervention product compared with tricycle users. Conclusion Use of wheel-mounted accelerometers as a means to test user mobility proved to be a feasible methodology in rural settings. Variability in wheeled mobility data could be decreased with longer acclimatisation periods. The data suggest that push rim users experience an easier transition to a dual-lever propulsion system. PMID:28936416
Stanfill, Christopher J; Jensen, Jody L
2017-01-01
Wheelchair research includes both qualitative and quantitative approaches, primarily focuses on functionality and skill performance and is often limited to short testing periods. This is the first study to use the combination of a performance test (i.e. wheelchair propulsion test) and a multiple-day mobility assessment to evaluate wheelchair designs in rural areas of a developing country. Test the feasibility of using wheel-mounted accelerometers to document bouts of wheeled mobility data in rural settings and use these data to compare how patients respond to different wheelchair designs. A quasi-experimental, pre- and post-test design was used to test the differences between locally manufactured wheelchairs (push rim and tricycle) and an imported intervention product (dual-lever propulsion wheelchair). A one-way repeated measures analysis of variance was used to interpret propulsion and wheeled mobility data. There were no statistical differences in bouts of mobility between the locally manufactured and intervention product, which was explained by high amounts of variability within the data. With regard to the propulsion test, push rim users were significantly more efficient when using the intervention product compared with tricycle users. Use of wheel-mounted accelerometers as a means to test user mobility proved to be a feasible methodology in rural settings. Variability in wheeled mobility data could be decreased with longer acclimatisation periods. The data suggest that push rim users experience an easier transition to a dual-lever propulsion system.
Almeida, Fernando; Renovell, Pablo; Morante, Elena; López, Raúl
2013-01-01
Background A two-stage revision remains as the "gold standard" treatment for chronically infected total knee arthroplasties. Methods Forty-five septic knee prostheses were revised with a minimum follow-up of 5 years. Static antibiotic-impregnated cement spacers were used in all cases. Intravenous antibiotics according to sensitivity test of the culture were applied during patients' hospital stay. Oral antibiotics were given for another 5 weeks. Second-stage surgery was undertaken after control of infection with normal erythrocyte sedimentation rate and C-reactive protein values. Extensile techniques were used if needed and metallic augments were employed for bone loss in 32 femoral and 29 tibial revisions. Results The average interval between the first-stage resection and reimplantation was 4.4 months. Significant improvement was obtained with respect to visual analog scale pain and clinical and functional scores, and infection was eradicated in 95.6% of cases following a two-stage revision total knee arthroplasty. Radiographic evaluation showed suitable alignment without signs of mechanical loosening. Conclusions This technique is a reasonable procedure to eradicate chronic infection in knee arthroplasty and provides proper functional and clinical results. However, it sometimes requires extensile surgical approaches that could imply arduous surgeries. Metallic augments with cementless stems available in most of the knee revision systems are a suitable alternative to handle bone deficiencies, avoiding the use of bone allografts with its complications. PMID:24009903
Silvestre, Antonio; Almeida, Fernando; Renovell, Pablo; Morante, Elena; López, Raúl
2013-09-01
A two-stage revision remains as the "gold standard" treatment for chronically infected total knee arthroplasties. Forty-five septic knee prostheses were revised with a minimum follow-up of 5 years. Static antibiotic-impregnated cement spacers were used in all cases. Intravenous antibiotics according to sensitivity test of the culture were applied during patients' hospital stay. Oral antibiotics were given for another 5 weeks. Second-stage surgery was undertaken after control of infection with normal erythrocyte sedimentation rate and C-reactive protein values. Extensile techniques were used if needed and metallic augments were employed for bone loss in 32 femoral and 29 tibial revisions. The average interval between the first-stage resection and reimplantation was 4.4 months. Significant improvement was obtained with respect to visual analog scale pain and clinical and functional scores, and infection was eradicated in 95.6% of cases following a two-stage revision total knee arthroplasty. Radiographic evaluation showed suitable alignment without signs of mechanical loosening. This technique is a reasonable procedure to eradicate chronic infection in knee arthroplasty and provides proper functional and clinical results. However, it sometimes requires extensile surgical approaches that could imply arduous surgeries. Metallic augments with cementless stems available in most of the knee revision systems are a suitable alternative to handle bone deficiencies, avoiding the use of bone allografts with its complications.
Targeted Drug Delivery in the Suprachoroidal Space by Swollen Hydrogel Pushing.
Jung, Jae Hwan; Desit, Patcharin; Prausnitz, Mark R
2018-04-01
The purpose is to target model drug particles to the posterior region of the suprachoroidal space (SCS) of the eye controlled via pushing by hydrogel swelling. A particle formulation containing 1% hyaluronic acid (HA) with fluorescent polymer particles and a hydrogel formulation containing 4% HA were introduced in a single syringe as two layers without mixing, and injected sequentially into the SCS of the rabbit eye ex vivo and in vivo using a microneedle. Distribution of particles in the eye was determined by microscopy. During injection, the particle formulation was pushed toward the middle of the SCS by the viscous hydrogel formulation, but less than 12% of particles reached the posterior SCS. After injection, the particle formulation was pushed further toward the macula and optic nerve in the posterior SCS by hydrogel swelling and spreading. Heating the eye to 37°C, or injecting in vivo decreased viscosity and mechanical strength of the hydrogel, thereby allowing it to swell and flow further in the SCS. A high salt concentration (9% NaCl) in the hydrogel formulation further increased hydrogel swelling due to osmotic flow into the hydrogel. In this way, up to 76% of particles were delivered to the posterior SCS from an injection made near the limbus. This study shows that model drug particles can be targeted to the posterior SCS by HA hydrogel swelling and pushing without particle functionalization or administering external driving forces.
ERIC Educational Resources Information Center
Waters, John K.
2011-01-01
The vulnerability and inefficiency of backing up data on-site is prompting school districts to switch to more secure, less troublesome cloud-based options. District auditors are pushing for a better way to back up their data than the on-site, tape-based system that had been used for years. About three years ago, Hendrick School District in…
ERIC Educational Resources Information Center
Abrams, Fran
2009-01-01
The first decade of the current Labour Government had been characterised by a whole raft of education reforms aimed at driving up standards--a focus on early literacy and numeracy, standards funds to push up exam results, the much greater use of technology to track individual pupils' progress and to ensure a growing number achieved the benchmark…
76 FR 59069 - Revision to the Section 8 Management Assessment Program Lease-Up Indicator
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-23
...-AC76 Revision to the Section 8 Management Assessment Program Lease-Up Indicator AGENCY: Office of the... process by which HUD measures and verifies performance under the SEMAP lease-up indicator. Specifically... (PHA) leasing indicator will be based on a calendar year cycle, rather than a fiscal year cycle, which...
Wang, Vivian J-J; Chen, Ya-Ming; Yip, Kevin H-K; Smales, Roger J; Meng, Qing-Fei; Chen, Lijuan
2008-03-01
To investigate regional root canal push-out bond strengths for two fiber-reinforced post types using two adhesive systems. The crowns of 24 recently extracted sound maxillary central incisors were sectioned transversely 2 mm coronal to the labial cemento-enamel junction, and the roots treated endodontically. Following standardized post space preparations, fiber-reinforced posts (C-POST; AESTHETI-PLUS) were placed using two adhesive systems (acid-etch ONE-STEP PLUS/C&B CEMENT; self-adhesive RelyX Unicem), in four equal groups. Push-out bond strength tests were performed at four sites in each root. Results were analyzed using split-plot ANOVA, with a=0.05 for statistical significance. AESTHETI-PLUS quartz fiber-reinforced posts showed significantly higher push-out strengths than C-POST carbon fiber-reinforced posts (P<0.0001). The separate acid-etch adhesive system resulted in significantly higher bond strengths than the self-etch self-adhesive system (P<0.0001). Bond strengths decreased significantly from coronal to apical root canal regions (P<0.0001). The quartz fiber-reinforced post placed using the separate acid-etch adhesive system provided significantly better post retention than the carbon fiber-reinforced post placed using the self-etch self-adhesive system.
Woods, Carl T; Keller, Brad S; McKeown, Ian; Robertson, Sam
2016-09-01
Woods, CT, Keller, BS, McKeown, I, and Robertson, S. A comparison of athletic movement among talent-identified juniors from different football codes in Australia: implications for talent development. J Strength Cond Res 30(9): 2440-2445, 2016-This study aimed to compare the athletic movement skill of talent-identified (TID) junior Australian Rules football (ARF) and soccer players. The athletic movement skill of 17 TID junior ARF players (17.5-18.3 years) was compared against 17 TID junior soccer players (17.9-18.7 years). Players in both groups were members of an elite junior talent development program within their respective football codes. All players performed an athletic movement assessment that included an overhead squat, double lunge, single-leg Romanian deadlift (both movements performed on right and left legs), a push-up, and a chin-up. Each movement was scored across 3 essential assessment criteria using a 3-point scale. The total score for each movement (maximum of 9) and the overall total score (maximum of 63) were used as the criterion variables for analysis. A multivariate analysis of variance tested the main effect of football code (2 levels) on the criterion variables, whereas a 1-way analysis of variance identified where differences occurred. A significant effect was noted, with the TID junior ARF players outscoring their soccer counterparts when performing the overhead squat and push-up. No other criterions significantly differed according to the main effect. Practitioners should be aware that specific sporting requirements may incur slight differences in athletic movement skill among TID juniors from different football codes. However, given the low athletic movement skill noted in both football codes, developmental coaches should address the underlying movement skill capabilities of juniors when prescribing physical training in both codes.
Real-time feedback enhances forward propulsion during walking in old adults.
Franz, Jason R; Maletis, Michela; Kram, Rodger
2014-01-01
Reduced propulsive function during the push-off phase of walking plays a central role in the deterioration of walking ability with age. We used real-time propulsive feedback to test the hypothesis that old adults have an underutilized propulsive reserve available during walking. 8 old adults (mean [SD], age: 72.1 [3.9] years) and 11 young adults (age: 21.0 [1.5] years) participated. For our primary aim, old subjects walked: 1) normally, 2) with visual feedback of their peak propulsive ground reaction forces, and 3) with visual feedback of their medial gastrocnemius electromyographic activity during push-off. We asked those subjects to match a target set to 20% and 40% greater propulsive force or push-off muscle activity than normal walking. We tested young subjects walking normally only to provide reference ground reaction force values. Walking normally, old adults exerted 12.5% smaller peak propulsive forces than young adults (P<0.01). However, old adults significantly increased their propulsive forces and push-off muscle activities when we provided propulsive feedback. Most notably, force feedback elicited propulsive forces that were equal to or 10.5% greater than those of young adults (+20% target, P=0.87; +40% target, P=0.02). With electromyographic feedback, old adults significantly increased their push-off muscle activities but without increasing their propulsive forces. Old adults with propulsive deficits have a considerable and underutilized propulsive reserve available during level walking. Further, real-time propulsive feedback represents a promising therapeutic strategy to improve the forward propulsion of old adults and thus maintain their walking ability and independence. © 2013.
Design of a haptic device with grasp and push-pull force feedback for a master-slave surgical robot.
Hu, Zhenkai; Yoon, Chae-Hyun; Park, Samuel Byeongjun; Jo, Yung-Ho
2016-07-01
We propose a portable haptic device providing grasp (kinesthetic) and push-pull (cutaneous) sensations for optical-motion-capture master interfaces. Although optical-motion-capture master interfaces for surgical robot systems can overcome the stiffness, friction, and coupling problems of mechanical master interfaces, it is difficult to add haptic feedback to an optical-motion-capture master interface without constraining the free motion of the operator's hands. Therefore, we utilized a Bowden cable-driven mechanism to provide the grasp and push-pull sensation while retaining the free hand motion of the optical-motion capture master interface. To evaluate the haptic device, we construct a 2-DOF force sensing/force feedback system. We compare the sensed force and the reproduced force of the haptic device. Finally, a needle insertion test was done to evaluate the performance of the haptic interface in the master-slave system. The results demonstrate that both the grasp force feedback and the push-pull force feedback provided by the haptic interface closely matched with the sensed forces of the slave robot. We successfully apply our haptic interface in the optical-motion-capture master-slave system. The results of the needle insertion test showed that our haptic feedback can provide more safety than merely visual observation. We develop a suitable haptic device to produce both kinesthetic grasp force feedback and cutaneous push-pull force feedback. Our future research will include further objective performance evaluations of the optical-motion-capture master-slave robot system with our haptic interface in surgical scenarios.
Mixing with propylene glycol enhances the bond strength of mineral trioxide aggregate to dentin.
Salem Milani, Amin; Froughreyhani, Mohammad; Charchi Aghdam, Saeed; Pournaghiazar, Fatemeh; Asghari Jafarabadi, Mohammad
2013-11-01
Mixing mineral trioxide aggregate (MTA) with different proportions of propylene glycol (PG) improves its handling property. The aim of this study was to evaluate the effect of PG on MTA-dentin push-out bond strength. Seventy-five 2-mm-thick midroot sections were prepared from single-rooted human extracted teeth. The lumen of each slice was enlarged with Gates-Glidden burs. The slices were randomly divided into 3 groups (n = 25). In each group, 0.3 mL of the liquid was mixed with 1 g MTA (Angelus, Londrina, Brazil). The liquid vehicles used in groups 1-3 were 100% distilled water (DW), 20% PG-80% DW, and 100% PG, respectively. After incubation, the push-out strength of the samples was measured using a universal testing machine. The samples were then cut in halves and examined under a stereomicroscope to determine the failure pattern. One-way analysis of variance followed by the Tukey post hoc test was used to compare the push-out strength among groups. There were statistically significant differences between groups (P < .001). The push-out strength in group 1 (DW) was significantly lower than groups 2 and 3 (P < .001 and P = .022, respectively). However, there was no significant difference between groups 2 (DW-PG) and 3 (PG). Mixing MTA with PG increased its push-out bond strength to dentin. In the present study, the most suitable ratio was 80% DW-20% PG. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Mechanical manipulation of magnetic nanoparticles by magnetic force microscopy
NASA Astrophysics Data System (ADS)
Liu, Jinyun; Zhang, Wenxiao; Li, Yiquan; Zhu, Hanxing; Qiu, Renxi; Song, Zhengxun; Wang, Zuobin; Li, Dayou
2017-12-01
A method has been developed in this work for the mechanical manipulation of magnetic nanoparticles (MNPs). A helical curve was designed as the capture path to pick up and remove the target nanoparticle on a mica surface by a magnetic probe based on the magnetic force microscope (MFM). There were magnetic, tangential and pushing forces acting on the target particle during the approaching process when the tip followed the helical curve as the capture path. The magnetic force was significant when the tip was closer to the particle. The target particle can be attached on the surface of the magnetic probe tip and then be picked up after the tip retracted from the mica surface. Theoretical analysis and experimental results were presented for the pick-up and removal of MNPs. With this method, the precision and flexibility of manipulation of MNPs were improved significantly compared to the pushing or sliding of the target object away from the corresponding original location following a planned path.
LOAD-ENHANCED MOVEMENT QUALITY SCREENING AND TACTICAL ATHLETICISM: AN EXTENSION OF EVIDENCE
Schmitz, Randy J.; Rhea, Christopher K.; Ross, Scott E.
2017-01-01
Background Military organizations use movement quality screening for prediction of injury risk and performance potential. Currently, evidence of an association between movement quality and performance is limited. Recent work has demonstrated that external loading strengthens the relationship between movement screens and performance outcomes. Such loading may therefore steer us toward robust implementations of movement quality screens while maintaining their appeal as cost effective, field-expedient tools. Purpose The purpose of the current study was to quantify the effect of external load-bearing on the relationship between clinically rated movement quality and tactical performance outcomes while addressing the noted limitations. Study Design Crossover Trial. Methods Fifty young adults (25 male, 25 female, 22.98 ± 3.09 years, 171.95 ± 11.46 cm, 71.77 ± 14.03 kg) completed the Functional Movement Screen™ with (FMS™W) and without (FMS™C) a weight vest in randomized order. Following FMS™ testing, criterion measures of tactical performance were administered, including agility T-Tests, sprints, a 400-meter run, the Mobility for Battle (MOB) course, and a simulated casualty rescue. For each performance outcome, regression models were selected via group lasso with smoothed FMS™ item scores as candidate predictor variables. Results For all outcomes, proportion of variance accounted for was greater in FMS™W (R2 = ;0.22 [T-Test], 0.29 [Sprint], 0.17 [400 meter], 0.29 [MOB], and 0.11 [casualty rescue]) than in FMS™C (R2 = ;0.00 [T-Test], 0.11 [Sprint], 0.00 [400 meter], 0.19 [MOB], and 0.00 [casualty rescue]). From the FMS™W condition, beneficial performance effects (p<0.05) were observed for Deep Squat (sprint, casualty rescue), Hurdle Step (T-Agility, 400 meter run), Inline Lunge (sprint, MOB), and Trunk Stability Push Up (all models). Similar effects for FMS™C item scores were limited to Trunk Stability Push Up (p<0.05, all models). Conclusions The present study extends evidence supporting the validity of load-enhanced movement quality screening as a predictor of tactical performance ability. Future designs should seek to identify mechanisms explaining this effect. Level of Evidence 3 PMID:28593095
LOAD-ENHANCED MOVEMENT QUALITY SCREENING AND TACTICAL ATHLETICISM: AN EXTENSION OF EVIDENCE.
Glass, Stephen M; Schmitz, Randy J; Rhea, Christopher K; Ross, Scott E
2017-06-01
Military organizations use movement quality screening for prediction of injury risk and performance potential. Currently, evidence of an association between movement quality and performance is limited. Recent work has demonstrated that external loading strengthens the relationship between movement screens and performance outcomes. Such loading may therefore steer us toward robust implementations of movement quality screens while maintaining their appeal as cost effective, field-expedient tools. The purpose of the current study was to quantify the effect of external load-bearing on the relationship between clinically rated movement quality and tactical performance outcomes while addressing the noted limitations. Crossover Trial. Fifty young adults (25 male, 25 female, 22.98 ± 3.09 years, 171.95 ± 11.46 cm, 71.77 ± 14.03 kg) completed the Functional Movement Screen™ with (FMS™W) and without (FMS™C) a weight vest in randomized order. Following FMS™ testing, criterion measures of tactical performance were administered, including agility T-Tests, sprints, a 400-meter run, the Mobility for Battle (MOB) course, and a simulated casualty rescue. For each performance outcome, regression models were selected via group lasso with smoothed FMS™ item scores as candidate predictor variables. For all outcomes, proportion of variance accounted for was greater in FMS™W (R 2 = ;0.22 [T-Test], 0.29 [Sprint], 0.17 [400 meter], 0.29 [MOB], and 0.11 [casualty rescue]) than in FMS™C (R 2 = ;0.00 [T-Test], 0.11 [Sprint], 0.00 [400 meter], 0.19 [MOB], and 0.00 [casualty rescue]). From the FMS™W condition, beneficial performance effects (p<0.05) were observed for Deep Squat (sprint, casualty rescue), Hurdle Step (T-Agility, 400 meter run), Inline Lunge (sprint, MOB), and Trunk Stability Push Up (all models). Similar effects for FMS™C item scores were limited to Trunk Stability Push Up (p<0.05, all models). The present study extends evidence supporting the validity of load-enhanced movement quality screening as a predictor of tactical performance ability. Future designs should seek to identify mechanisms explaining this effect. 3.
Radiographic evaluation of short-stem press-fit total shoulder arthroplasty: short-term follow-up.
Casagrande, Danielle J; Parks, Di L; Torngren, Travis; Schrumpf, Mark A; Harmsen, Samuel M; Norris, Tom R; Kelly, James D
2016-07-01
Humeral loosening is an uncommon etiology for revision shoulder arthroplasty. We aimed to evaluate the radiographic and clinical outcomes of a short-stem press-fit humeral component after primary total shoulder arthroplasty. We reviewed our patient database, from January 2008 to December 2011, for primary total shoulder arthroplasties performed with a short-stem press-fit humeral component. Radiographs and clinical outcomes were evaluated in the immediate postoperative period and at the most recent follow-up, with at least 24 months of data for all patients. There were 73 shoulders that met our inclusion criteria, but 4 underwent revision before 2 years' follow-up. Only 1 of these 4 was revised for aseptic humeral loosening. Sixty-nine shoulders had at least 24 months of radiographic follow-up, and 62 had radiographic and clinical follow-up. Of the 69 shoulders, 5 underwent revision for humeral loosening: 1 for aseptic loosening and 4 for infection. Two other shoulders with humeral loosening were asymptomatic, and the patients refused revision surgery. The overall revision rate for humeral loosening was 8.2% (6 of 73 shoulders). Radiolucent zones of any size were seen in 71.0%, with 8.7% of these shoulders identified as having humeral stems at risk of future loosening. Significant improvements were made in most of the measured clinical outcomes. A high percentage of radiolucency was seen around the short-stem press-fit humeral components evaluated in this study at short-term follow-up. The overall rates of loosening and revision for the humeral implant examined in this study are higher than those noted in other recent studies evaluating press-fit stems. The cause of radiolucency and humeral loosening for this implant is not fully understood. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Halford, A. J.
2017-12-01
When space computers first started listening into space radio, they noticed that there were radio noises that happened on the morning side of the Earth. Because these waves sounded like noises birds make in the morning, we named these waves after them. These bird sounding waves can move around the Earth, flying up and down, and sometimes move into an area where there is more stuff. This area is also much colder than where these bird noises are first made. When the waves move into this cold area where there is more stuff, they start to sound like angry birds instead of happy birds. Both of these waves, the happy and angry bird sounding waves, are very important to our understanding of how the tiny things in space move and change. Sometimes the waves which sound like birds can push these tiniest of things into the sky. The happy bird sounding waves can push the tiniest things quickly while the angry bird sounding waves push the tinest of things more slowly. When the tiny things fall into the sky, they create beautiful space lights and light that burns which can hurt people in up goers and not so up goers as well as our things like phones, and space computers. We study these waves that sound like birds to better understand when and where the tiny things will fall. That way we can be prepared and enjoy watching the pretty space lights at night with no worries.
Hancock, Douglas S; Sharplin, Paul K; Larsen, Peter D; Phillips, Fredrick Ts
2018-05-01
To assess early radiological and functional outcomes of revision hip surgery with a cementless press-fit design femoral stem. A retrospective review of 48 consecutive revision total hip replacements using the RECLAIM revision hip system, between October 2012 and August 2015. Radiographic assessment was undertaken with serial anteroposterior (AP) X-rays of the pelvis. Risk factors for subsidence were evaluated. Prospective clinical follow up was performed on 21 patients to assess functional outcomes. Mean stem subsidence was 1.1 mm (95% confidence interval[CI]: 0.63-1.57). Median follow up of 12 months. An inverse relationship was observed between level of subsidence and femoral stem diameter r = -0.45, p = 0.001. Subsidence at the time of follow-up assessment was correlated with initial subsidence (correlation coefficient rho 0.69, p = 0.001). The mean Merle d'Aubigne score at the latest follow up was 14.2 (range 8-17). The mean OHS was 34.1 (range 15-48). Early radiological and functional outcomes for the RECLAIM revision system showed very low levels of subsidence and good functional outcomes. There was an association with smaller diameter femoral stems and greater levels of subsidence.
Do Changes in the Production Process Affect the Outcome of Ceramic Liners: A 3-Year Follow-Up Study.
Schmidt-Braekling, Tom; Renner, Lisa; Mintz, Douglas N; Waldstein, Wenzel; Endo, Yoshimi; Boettner, Friedrich
2017-04-01
In 2011, the current liner was withdrawn from the market because of the potential risk for liner fracture secondary to increased pressures used to assemble the metal locking ring. The present study provides a short-term follow-up of patients with this implant. We retrospectively evaluated 63 consecutive hips in 53 patients operated by a single surgeon using a recalled ceramic-on-ceramic bearing. There were 30 women and 23 men with an average age of 50.6 years (range 20.3-63.5 years). The mean follow-up was 36.8 months. Six hips in 6 patients were revised (9.5%) because of a liner-fracture during the follow-up period. All liner fractures were identified on computer tomography imaging. Nine patients had self-reported episodes of squeaking (14.3%). All 6 patients that underwent revision surgery for liner fracture described squeaking before revision. There were no revisions for other causes. Two of the revised patients had a subsequent dislocation (33%). The recalled ceramic liner lots have an increased liner fracture rate. Patients with mechanical symptoms or squeaking should undergo computer tomography to rule out liner facture. Copyright © 2016 Elsevier Inc. All rights reserved.
Soo, Caroline H; Donelan, J Maxwell
2012-02-01
In human walking, each transition to a new stance limb requires redirection of the center of mass (COM) velocity from one inverted pendulum arc to the next. While this can be accomplished with either negative collision work by the leading limb, positive push-off work by the trailing limb, or some combination of the two, physics-based models of step-to-step transitions predict that total positive work is minimized when the push-off and collision work are equal in magnitude. Here, we tested the importance of the coordination of push-off and collision work in determining transition work using ankle and knee joint braces to limit the ability of a leg to perform positive work on the body. To isolate transitions from other contributors to walking mechanics, participants were instructed to rock back and forth from one leg to the other, restricting motion to the sagittal plane and eliminating the need to swing the legs. We found that reduced push-off work increased the collision work required to complete the redirection of the COM velocity during each transition. A greater amount of total mechanical work was required when rocking departed from the predicted optimal coordination of step-to-step transitions, in which push-off and collision work are equal in magnitude. Our finding that transition work increases if one or both legs do not push-off with the optimal coordination may help explain the elevated metabolic cost of pathological gait irrespective of etiology. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Maiti, Amitesh; Svizhenko, Alexei; Anantram, M. P.; Biegel, Bryan (Technical Monitor)
2001-01-01
Atomistic simulations using a combination of classical force field and Density-Functional-Theory (DFT) show that carbon atoms remain essentially sp2 coordinated in either bent tubes or tubes pushed by an atomically sharp AFM tip. Subsequent Green's-function-based transport calculations reveal that for armchair tubes there is no significant drop in conductance, while for zigzag tubes the conductance can drop by several orders of magnitude in AFM-pushed tubes. The effect can be attributed to simple stretching of the tube under tip deformation, which opens up an energy gap at the Fermi surface.
ERIC Educational Resources Information Center
Idaho State Dept. of Education, Boise. Div. of Vocational Education.
Under the Idaho state system for curriculum development in vocational education, Technical Committees made up solely of industry personnel are responsible for drawing up task lists for each program. Accordingly, a task list for dental assistants was drawn up and used as a basis for revising the curriculum guide for fundamentals of dental assisting…
Does dynamic stability govern propulsive force generation in human walking?
Browne, Michael G.
2017-01-01
Before succumbing to slower speeds, older adults may walk with a diminished push-off to prioritize stability over mobility. However, direct evidence for trade-offs between push-off intensity and balance control in human walking, independent of changes in speed, has remained elusive. As a critical first step, we conducted two experiments to investigate: (i) the independent effects of walking speed and propulsive force (FP) generation on dynamic stability in young adults, and (ii) the extent to which young adults prioritize dynamic stability in selecting their preferred combination of walking speed and FP generation. Subjects walked on a force-measuring treadmill across a range of speeds as well as at constant speeds while modulating their FP according to a visual biofeedback paradigm based on real-time force measurements. In contrast to improvements when walking slower, walking with a diminished push-off worsened dynamic stability by up to 32%. Rather, we find that young adults adopt an FP at their preferred walking speed that maximizes dynamic stability. One implication of these findings is that the onset of a diminished push-off in old age may independently contribute to poorer balance control and precipitate slower walking speeds. PMID:29291129
Does dynamic stability govern propulsive force generation in human walking?
Browne, Michael G; Franz, Jason R
2017-11-01
Before succumbing to slower speeds, older adults may walk with a diminished push-off to prioritize stability over mobility. However, direct evidence for trade-offs between push-off intensity and balance control in human walking, independent of changes in speed, has remained elusive. As a critical first step, we conducted two experiments to investigate: (i) the independent effects of walking speed and propulsive force ( F P ) generation on dynamic stability in young adults, and (ii) the extent to which young adults prioritize dynamic stability in selecting their preferred combination of walking speed and F P generation. Subjects walked on a force-measuring treadmill across a range of speeds as well as at constant speeds while modulating their F P according to a visual biofeedback paradigm based on real-time force measurements. In contrast to improvements when walking slower, walking with a diminished push-off worsened dynamic stability by up to 32%. Rather, we find that young adults adopt an F P at their preferred walking speed that maximizes dynamic stability. One implication of these findings is that the onset of a diminished push-off in old age may independently contribute to poorer balance control and precipitate slower walking speeds.
Analysis of Rapid Multi-Focal Zone ARFI Imaging
Rosenzweig, Stephen; Palmeri, Mark; Nightingale, Kathryn
2015-01-01
Acoustic radiation force impulse (ARFI) imaging has shown promise for visualizing structure and pathology within multiple organs; however, because the contrast depends on the push beam excitation width, image quality suffers outside of the region of excitation. Multi-focal zone ARFI imaging has previously been used to extend the region of excitation (ROE), but the increased acquisition duration and acoustic exposure have limited its utility. Supersonic shear wave imaging has previously demonstrated that through technological improvements in ultrasound scanners and power supplies, it is possible to rapidly push at multiple locations prior to tracking displacements, facilitating extended depth of field shear wave sources. Similarly, ARFI imaging can utilize these same radiation force excitations to achieve tight pushing beams with a large depth of field. Finite element method simulations and experimental data are presented demonstrating that single- and rapid multi-focal zone ARFI have comparable image quality (less than 20% loss in contrast), but the multi-focal zone approach has an extended axial region of excitation. Additionally, as compared to single push sequences, the rapid multi-focal zone acquisitions improve the contrast to noise ratio by up to 40% in an example 4 mm diameter lesion. PMID:25643078
El-Gohary, Mahmoud; Peterson, Daniel; Gera, Geetanjali; Horak, Fay B; Huisinga, Jessie M
2017-07-01
To test the validity of wearable inertial sensors to provide objective measures of postural stepping responses to the push and release clinical test in people with multiple sclerosis. Cross-sectional study. University medical center balance disorder laboratory. Total sample N=73; persons with multiple sclerosis (PwMS) n=52; healthy controls n=21. Stepping latency, time and number of steps required to reach stability, and initial step length were calculated using 3 inertial measurement units placed on participants' lumbar spine and feet. Correlations between inertial sensor measures and measures obtained from the laboratory-based systems were moderate to strong and statistically significant for all variables: time to release (r=.992), latency (r=.655), time to stability (r=.847), time of first heel strike (r=.665), number of steps (r=.825), and first step length (r=.592). Compared with healthy controls, PwMS demonstrated a longer time to stability and required a larger number of steps to reach stability. The instrumented push and release test is a valid measure of postural responses in PwMS and could be used as a clinical outcome measures for patient care decisions or for clinical trials aimed at improving postural control in PwMS. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Flexibility is associated with motor competence in schoolchildren.
Lopes, L; Póvoas, S; Mota, J; Okely, A D; Coelho-E-Silva, M J; Cliff, D P; Lopes, V P; Santos, R
2017-12-01
Available data on the associations between motor competence (MC) and flexibility are limited and result inconclusive. This study aims to examine the relationship between flexibility and MC in children. The sample comprised 596 Portuguese children (47.1% girls) aged 9.7 ± 0.6 years. Motor competence was evaluated with the body coordination test, Körperkoordination Test für Kinder. Cardiorespiratory fitness (20-m shuttle run), muscular strength (curl-up and push-up tests), and flexibility (back-saver sit and reach and trunk-lift tests) were evaluated using the Fitnessgram Test Battery. Z-scores by age and gender for the physical fitness tests were constructed. Analysis of variance and regression analysis were performed. Participants in the healthy zone groups of both flexibility tests exhibited significantly better scores of MC than the participants under the healthy zone (P < 0.001). Back-saver sit and reach and trunk-lift Z-scores, either individually or as a sum, were significant predictors of MC (P < 0.05 for all) after adjustments for the other physical fitness components, age, body mass index, and socioeconomic status, in both genders. Our findings highlight the importance of promoting and developing flexibility, as well as the other health-related physical fitness components in schoolchildren to reach adequate levels of MC. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Assessment of modified gold surfaced titanium implants on skeletal fixation
Zainali, Kasra; Danscher, Gorm; Jakobsen, Thomas; Baas, Jorgen; Møller, Per; Bechtold, Joan E.; Soballe, Kjeld
2013-01-01
Noncemented implants are the primary choice for younger patients undergoing total hip replacements. However, the major concern in this group of patients regarding revision is the concern from wear particles, periimplant inflammation, and subsequently aseptic implant loosening. Macrophages have been shown to liberate gold ions through the process termed dissolucytosis. Furthermore, gold ions are known to act in an anti-inflammatory manner by inhibiting cellular NF-κB-DNA binding. The present study investigated whether partial coating of titanium implants could augment early osseointegration and increase mechanical fixation. Cylindrical porous coated Ti-6Al-4V implants partially coated with metallic gold were inserted in the proximal region of the humerus in ten canines and control implants without gold were inserted in contralateral humerus. Observation time was 4 weeks. Biomechanical push out tests and stereological histomorphometrical analyses showed no statistically significant differences in the two groups. The unchanged parameters are considered an improvement of the coating properties, as a previous complete gold-coated implant showed inferior mechanical fixation and reduced osseointegration compared to control titanium implants in a similar model. Since sufficient early mechanical fixation is achieved with this new coating, it is reasonable to investigate the implant further in long-term studies. PMID:22847873
Recruit Fitness as a Predictor of Police Academy Graduation.
Shusko, M; Benedetti, L; Korre, M; Eshleman, E J; Farioli, A; Christophi, C A; Kales, S N
2017-10-01
Suboptimal recruit fitness may be a risk factor for poor performance, injury, illness, and lost time during police academy training. To assess the probability of successful completion and graduation from a police academy as a function of recruits' baseline fitness levels at the time of academy entry. Retrospective study where all available records from recruit training courses held (2006-2012) at all Massachusetts municipal police academies were reviewed and analysed. Entry fitness levels were quantified from the following measures, as recorded at the start of each training class: body composition, push-ups, sit-ups, sit-and-reach, and 1.5-mile run-time. The primary outcome of interest was the odds of not successfully graduating from an academy. We used generalized linear mixed models in order to fit logistic regression models with random intercepts for assessing the probability of not graduating, based on entry-level fitness. The primary analyses were restricted to recruits with complete entry-level fitness data. The fitness measures most strongly associated with academy failure were lesser number of push-ups completed (odds ratio [OR] = 5.2, 95% confidence interval [CI] 2.3-11.7, for 20 versus 41-60 push-ups) and slower run times (OR = 3.8, 95% CI 1.8-7.8, [1.5 mile run time of ≥15'20″] versus [12'33″ to 10'37″]). Baseline pushups and 1.5-mile run-time showed the best ability to predict successful academy graduation, especially when considered together. Future research should include prospective validation of entry-level fitness as a predictor of subsequent police academy success. © The Author 2017. Published by Oxford University Press on behalf of the Society of Occupational Medicine.
Briant-Evans, Toby W; Veeramootoo, Darmaraja; Tsiridis, Eleftherios; Hubble, Matthew J
2009-10-01
Revision surgery for periprosthetic femoral fractures around an unstable cemented femoral stem traditionally requires removal of existing cement. We propose a new technique whereby a well-fixed cement mantle can be retained in cases with simple fractures that can be reduced anatomically when a cemented revision is planned. This technique is well established in femoral stem revision, but not in association with a fracture. We treated 23 Vancouver type B periprosthetic femoral fractures by reducing the fracture and cementing a revision stem into the pre-existing cement mantle, with or without supplementary fixation. 3 patients died in the first 6 months for reasons unrelated to surgery. In addition, 1 was too frail to attend follow-up and was therefore excluded from the study, and 1 patient underwent revision surgery for a nonunion. The remaining 18 cases all healed with radiographic union after an average time of 4.4 (2-11) months. There was no sign of loosening or subsidence of the revision stems within the old cement mantle in any of these cases at the most recent follow-up after an average of 3 (0.3-9) years. Our results support the use of the cement-in-cement revision in anatomically reducible periprosthetic fractures with a well-preserved pre-existing cement mantle. This technique is particularly useful for the elderly patient and for those who are not fit for prolonged surgical procedures.
Drug Testing of Public Employees: An Introduction.
ERIC Educational Resources Information Center
Jascourt, Hugh D.
1988-01-01
The Federal Government has pushed employers to establish programs to test applicants and employees for drug use. The accompanying articles discuss legal barriers to drug testing and test administration and practical problems that limit the feasibility of drug testing and carry with them potential legal problems. (MLF)
NASA Astrophysics Data System (ADS)
Jiango, Homin; Liuo, Howard; Guzzino, Kim
2016-07-01
In this study, the design of a 4 bit, 10-gigasamples-per-second analog-to-digital converter (ADC) printed circuit board assembly (PCBA) was revised, manufactured, and tested. It is used for digitizing radio telescopes. An Adsantec ANST7120-KMA flash ADC chip was used, as in the original design. Associated with the field-programmable gate array platform developed by the Collaboration for Astronomy Signal Processing and Electronics Research community, the developed PCBA provides data acquisition systems with a wider bandwidth and simplifies the intermediate frequency section. The current version of the PCBA exhibits an analog bandwidth of up to 10 GHz (3 dB loss), and the chip exhibits an analog bandwidth of up to 18 GHz. This facilitates second and third Nyquist sampling. The following worstcase performance parameters were obtained from the revised PCBA at over 5 GHz: spurious-free dynamic range of 12 dB, signal-to-noise and distortion ratio of 2 dB, and effective number of bits of 0.7. The design bugs in the ADC chip caused the poor performance. The vendor created a new batch run and confirmed that the ADC chips of the new batch will meet the specifications addressed in its data sheet.
Liu, Gaisheng; Bohling, Geoffrey C.; Butler, James J.
2008-01-01
The direct‐push permeameter (DPP) is a tool for the in situ characterization of hydraulic conductivity (K) in shallow, unconsolidated formations. This device, which consists of a short screened section with a pair of pressure transducers near the screen, is advanced into the subsurface with direct‐push technology. K is determined through a series of injection tests conducted between advancements. Recent field work by Butler et al. (2007) has shown that the DPP holds great potential for describing vertical variations in K at an unprecedented level of detail, accuracy and speed. In this paper, the fundamental efficacy of the DPP is evaluated through a series of numerical simulations. These simulations demonstrate that the DPP can provide accurate K information under conditions commonly faced in the field. A single DPP test provides an effective K for the domain immediately surrounding the interval between the injection screen and the most distant pressure transducer. Features that are thinner than that interval can be quantified by reducing the vertical distance between successive tests and analyzing the data from all tests simultaneously. A particular advantage of the DPP is that, unlike most other single borehole techniques, a low‐K skin or a clogged screen has a minimal impact on the K estimate. In addition, the requirement that only steady‐shape conditions be attained allows for a dramatic reduction in the time required for each injection test.
Diagnostic and statistical manual-5: Position paper of the Indian Psychiatric Society
Jacob, K. S.; Kallivayalil, R. A.; Mallik, A. K.; Gupta, N.; Trivedi, J. K.; Gangadhar, B. N.; Praveenlal, K.; Vahia, V.; Rao, T. S. Sathyanarayana
2013-01-01
The development of the Diagnostic and Statistical Manual-5 (DSM-5) has been an exhaustive and elaborate exercise involving the review of DSM-IV categories, identifying new evidence and ideas, field testing, and revising issues in order that it is based on the best available evidence. This report of the Task Force of the Indian Psychiatric Society examines the current draft of the DSM-5 and discusses the implications from an Indian perspective. It highlights the issues related to the use of universal categories applied across diverse cultures. It reiterates the evidence for mental disorders commonly seen in India. It emphasizes the need for caution when clinical categories useful to specialists are employed in the contexts of primary care and in community settings. While the DSM-5 is essentially for the membership of the American Psychiatric Association, its impact will be felt far beyond the boundaries of psychiatry and that of the United States of America. However, its atheoretical approach, despite its pretensions, pushes a purely biomedical agenda to the exclusion of other approaches to mental health and illness. Nevertheless, the DSM-5 should serve a gate-keeping function, which intends to set minimum standards. It is work in progress and will continue to evolve with the generation of new evidence. For the DSM-5 to be relevant and useful across the cultures and countries, it needs to be broad-based and consider social and cultural contexts, issues, and phenomena. The convergence and compatibility with International Classification of Diseases-11 is a worthy goal. While the phenomenal effort of the DSM-5 revision is commendable, psychiatry should continue to strive for a more holistic understanding of mental health, illness, and disease. PMID:23441009
Measuring Students' Physical Activity Levels: Validating SOFIT for Use with High-School Students
ERIC Educational Resources Information Center
van der Mars, Hans; Rowe, Paul J.; Schuldheisz, Joel M.; Fox, Susan
2004-01-01
This study was conducted to validate the System for Observing Fitness Instruction Time (SOFIT) for measuring physical activity levels of high-school students. Thirty-five students (21 girls and 14 boys from grades 9-12) completed a standardized protocol including lying, sitting, standing, walking, running, curl-ups, and push-ups. Heart rates and…
They Thought Globally, But Now Colleges Push Online Programs Locally
ERIC Educational Resources Information Center
Parry, Marc
2009-01-01
For years, some universities have dreamed of border-defying online programs that vacuum up tuition dollars far beyond local students. But now a growing number of institutions are ramping up their efforts to attract working adults in their own backyards. Commuter-serving urban universities can not match the marketing muscle of faster-growing,…
FITNESS SCAVENGER HUNTS for Middle School Students
ERIC Educational Resources Information Center
Beighle, Aaron; Darst, Paul W.
2004-01-01
The field of physical education continues to shift from an emphasis on physical fitness to a focus on regular physical activity. Routines of the past such as jogging, push-ups, and sit-ups are now giving way to more thoughtful, creative routines designed to motivate students by making physical education more fun and diversified. Ranging from 7-10…
Neutral heel lateral push test: The first clinical examination of spring ligament integrity.
Pasapula, Chandra; Devany, Adam; Magan, Ahmed; Memarzadeh, A; Pasters, V; Shariff, S
2015-06-01
The spring (calcaneonavicular) ligament is an intricate multiligament complex whose primary role is to stabilise the medial longitudinal arch and head of talus. Clinical suspicion of a spring ligament injury in isolation is roused when persistent medial midfoot pain is present with associated pes planus following trauma. We undertook a cadaveric study on 21 specimens to assess the use of a neutral heel lateral push test to examine the spring ligament in a standardised procedure, measuring lateral translation with graduated antegrade and retrograde defunctioning of surrounding structures and the spring ligament. In all specimens, a significant displacement occurred on incision of the spring ligament regardless of order of dissection. The degree of displacement increased by an insignificant amount as surrounding structures were incised at each incremental force applied. The neutral heel push test is the first clinical examination to be described to determine integrity of the spring ligament complex. Our study objectively demonstrates that lateral displacement in relation to the mid and hind-foot is influenced most significantly by the integrity of the spring ligament and to a lesser extent by tibialis posterior and flexor digitorum longus. Copyright © 2015 Elsevier Ltd. All rights reserved.
2006-09-25
NASA's freshly painted Stratospheric Observatory for Infrared Astronomy (SOFIA) 747SP aircraft sits outside a hangar at L-3 Communications Integrated Systems' facility in Waco, Texas. The observatory, which features a German-built 100-inch (2.5 meter) diameter infrared telescope weighing 20 tons, is approaching the flight test phase as part of a joint program by NASA and DLR Deutsches Zentrum fuer Luft- und Raumfahrt (German Aerospace Center). SOFIA's science and mission operations are being planned jointly by Universities Space Research Association (USRA) and the Deutsches SOFIA Institut (DSI). Once operational, SOFIA will be the world's primary infrared observatory during a mission lasting up to 20 years, as well as an outstanding laboratory for developing and testing instrumentation and detector technology.
Upgraded Analytical Model of the Cylinder Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Souers, P. Clark; Lauderbach, Lisa; Garza, Raul
2013-03-15
A Gurney-type equation was previously corrected for wall thinning and angle of tilt, and now we have added shock wave attenuation in the copper wall and air gap energy loss. Extensive calculations were undertaken to calibrate the two new energy loss mechanisms across all explosives. The corrected Gurney equation is recommended for cylinder use over the original 1943 form. The effect of these corrections is to add more energy to the adiabat values from a relative volume of 2 to 7, with low energy explosives having the largest correction. The data was pushed up to a relative volume of aboutmore » 15 and the JWL parameter ω was obtained directly. The total detonation energy density was locked to the v=7 adiabat energy density, so that the Cylinder test gives all necessary values needed to make a JWL.« less
Upgraded Analytical Model of the Cylinder Test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Souers, P. Clark; Lauderbach, Lisa; Garza, Raul
2013-03-15
A Gurney-type equation was previously corrected for wall thinning and angle of tilt, and now we have added shock wave attenuation in the copper wall and air gap energy loss. Extensive calculations were undertaken to calibrate the two new energy loss mechanisms across all explosives. The corrected Gurney equation is recommended for cylinder use over the original 1943 form. The effect of these corrections is to add more energy to the adiabat values from a relative volume of 2 to 7, with low energy explosives having the largest correction. The data was pushed up to a relative volume of aboutmore » 15 and the JWL parameter ω was obtained directly. Finally, the total detonation energy density was locked to the v = 7 adiabat energy density, so that the Cylinder test gives all necessary values needed to make a JWL.« less
ERIC Educational Resources Information Center
Mowder, Barbara A.; Shamah, Renee
2011-01-01
This study evaluated the test-retest reliability of two parenting measures: the Parent Behavior Importance Questionnaire-Revised (PBIQ-R) and Parent Behavior Frequency Questionnaire-Revised (PBFQ-R). These self-report parenting behavior assessment measures may be utilized as pre- and post-parent education program measures, with parents as well as…
Anthropometric and performance measures to study talent detection in youth volleyball.
Melchiorri, Giovanni; Viero, Valerio; Triossi, Tamara; Annino, Giuseppe; Padua, Elvira; Tancredi, Virginia
2017-12-01
The aim of this work was to study anthropometric and performance measurements in 60 young male volleyball players (YV) and 60 youth not active in the sport (YNA) to assess which of these would be more useful to study the characteristics of potential performers. Eight measures to assess anthropometric characteristics, six performance measures and two tests for joint mobility were used. Also relative age and level of maturation were assessed. The anthropometric variables, relative age and level of maturation measured did not show statistically significant differences between groups. The YV and YNA groups showed differences in the performance measures. YV group was characterized by a better performance of the ability to repeat short sprints, of the upper limbs, abdominal muscles and lower limbs, with a medium effect size (Shuttle Running Test: 0.6; Push-Up: 0.5; Sit-Up: 0.4; counter movement jump: 0.4). These performance variables were very sensitive and specific: the SRT measurement had the best positive likelihood ratio that indicates the utility of the test in identifying type of players (YV and YNA). In talent detection in youth volleyball, in the 11-13 age range, performance variables should be preferred to anthropometric ones.
Granan, Lars-Petter; Baste, Valborg; Engebretsen, Lars; Inacio, Maria C S
2015-04-01
First, to evaluate whether the 2 year post-operative Knee injury and Osteoarthritis Outcome Score (KOOS) in primary anterior cruciate ligament reconstructions (ACLRs) was significantly different between patients that did not go on to have a subsequent revision after the 2 year post-operative control and the ones that did. Second, to test whether the "clinically failure" value of KOOS quality of life (QoL) < 44 was indicative of a clinically relevant difference in the risk of subsequent revision ACLR. ACLRs reported to the Norwegian Knee Ligament Registry between June 2004 and December 2009. 5,517 primary ACLRs with at least 2-year follow-up with KOOS QoL before revision surgery. There were clinically significant differences, adjusted and unadjusted, in both the KOOS Sport and Recreation and QoL subscales in patients with a later revision surgery compared to those that did not have a revision surgery. In adjusted models, the risk of later ACLR revision was 3.7 (95 % CI 2.2-6.0) higher in patients with a 2-year KOOS QoL < 44 compared to patients with a KOOS QoL ≥ 44. For every 10-point reduction in the KOOS QoL, a 33.6 % (95 % CI 21.2-47.5 %) higher risk for later ACLR revision was observed. This study reveals an association between inadequate knee function, as measured by KOOS, and a prospective ACL-reconstructed graft failure. Prognostic study (prospective cohort study), Level II.
Programmer's reference manual for the VAX-Gerber link software package. Revision 1. 0
DOE Office of Scientific and Technical Information (OSTI.GOV)
Isobe, G.W.
1985-10-01
This guide provides the information necessary to edit, modify, and run the VAX-Gerber software link. Since the project is in the testing stage and still being modified, this guide discussess the final desired stage along with the current stage. The current stage is to set up as to allow the programmer to easily modify and update codes as necessary.
Influence of an injury reduction program on injury and fitness outcomes among soldiers
Knapik, J; Bullock, S; Canada, S; Toney, E; Wells, J; Hoedebecke, E; Jones, B
2004-01-01
Objective: This study evaluated the influence of a multiple injury control intervention on injury and physical fitness outcomes among soldiers attending United States Army Ordnance School Advanced Individual Training. Methods: The study design was quasiexperimental involving a historical control group (n = 2559) that was compared to a multiple intervention group (n = 1283). Interventions in the multiple intervention group included modified physical training, injury education, and a unit based injury surveillance system (UBISS). The management responsible for training independently formed an Injury Control Advisory Committee that examined surveillance reports from the UBISS and recommended changes to training. On arrival at school, individual soldiers completed a demographics and lifestyle questionnaire and took an army physical fitness test (APFT: push-ups, sit-ups, and two mile run). Injuries among soldiers were tracked by a clinic based injury surveillance system that was separate from the UBISS. Soldiers completed a final APFT eight weeks after arrival at school. Results: Cox regression (survival analysis) was used to examine differences in time to the first injury while controlling for group differences in demographics, lifestyle characteristics, and physical fitness. The adjusted relative risk of a time loss injury was 1.5 (95% confidence interval 1.2 to 1.8) times higher in the historical control men and 1.8 (95% confidence interval 1.1 to 2.8) times higher in the historical control women compared with the multiple intervention men and women, respectively. After correcting for the lower initial fitness of the multiple intervention group, there were no significant differences between the multiple intervention and historical control groups in terms of improvements in push-ups, sit-ups, or two mile run performance. Conclusions: This multiple intervention program contributed to a reduction in injuries while improvements in physical fitness were similar to a traditional physical training program previously used at the school. PMID:14760025
Lamiani, Giulia; Setti, Ilaria; Barlascini, Luca; Vegni, Elena; Argentero, Piergiorgio
2017-03-01
Moral distress is a common experience among critical care professionals, leading to frustration, withdrawal from patient care, and job abandonment. Most of the studies on moral distress have used the Moral Distress Scale or its revised version (Moral Distress Scale-Revised). However, these scales have never been validated through factor analysis. This article aims to explore the factorial structure of the Moral Distress Scale-Revised and develop a valid and reliable scale through factor analysis. Validation study using a survey design. Eight medical-surgical ICUs in the north of Italy. A total of 184 clinicians (64 physicians, 94 nurses, and 14 residents). The Moral Distress Scale-Revised was translated into Italian and administered along with a measure of depression (Beck Depression Inventory-Second Edition) to establish convergent validity. Exploratory factor analysis was conducted to explore the Moral Distress Scale-Revised factorial structure. Items with low (less than or equal to 0.350) or multiple saturations were removed. The resulting model was tested through confirmatory factor analysis. The Italian Moral Distress Scale-Revised is composed of 14 items referring to four factors: futile care, poor teamwork, deceptive communication, and ethical misconduct. This model accounts for 59% of the total variance and presents a good fit with the data (root mean square error of approximation = 0.06; comparative fit index = 0.95; Tucker-Lewis index = 0.94; weighted root mean square residual = 0.65). The Italian Moral Distress Scale-Revised evinces good reliability (α = 0.81) and moderately correlates with Beck Depression Inventory-Second Edition (r = 0.293; p < 0.001). No significant differences were found in the moral distress total score between physicians and nurses. However, nurses scored higher on futile care than physicians (t = 2.051; p = 0.042), whereas physicians scored higher on deceptive communication than nurses (t = 3.617; p < 0.001). Moral distress was higher for those clinicians considering to give up their position (t = 2.778; p = 0.006). The Italian Moral Distress Scale-Revised is a valid and reliable instrument to assess moral distress among critical care clinicians and develop tailored interventions addressing its different components. Further research could test the generalizability of its factorial structure in other cultures.
Full-field fabric stress mapping by micro Raman spectroscopy in a yarn push-out test.
Lei, Z K; Qin, F Y; Fang, Q C; Bai, R X; Qiu, W; Chen, X
2018-02-01
The full-field stress distribution of a two-dimensional plain fabric was mapped using micro Raman spectroscopy (MRS) through a novel yarn push-out test, simulating a quasi-static projectile impact on the fabric. The stress-strain relationship for a single yarn was established using a digital image correlation method in a single-yarn tensile test. The relationship between Raman peak shift and aramid Kevlar 49 yarn stress was established using MRS in a single-yarn tensile test. An out-of-plane loading test was conducted on an aramid Kevlar 49 plain fabric, and the yarn stress was measured using MRS. From the full-field fabric stress distribution, it can be observed that there is a cross-shaped distribution of high yarn stress; this result would be helpful in further studies on load transfer on a fabric during a projectile impact.
Long-term follow-up after surgery in localized laryngeal amyloidosis.
Hazenberg, Aldert J C; Hazenberg, Bouke P C; Dikkers, Frederik G
2016-09-01
To study effectiveness of surgery and watchful waiting in localized laryngeal amyloidosis, retrospective case series. This retrospective study comprises all consecutive patients with localized laryngeal amyloidosis surgically treated in a tertiary hospital between 1994 and February 2016. Recurrence rate, revision surgery, progression to systemic amyloidosis, and changes in voice were monitored yearly. Eighteen patients were included. Seven women and eleven men had a median age 50 years (range 21-77 years) and median follow-up 6.4 years (2.4-17 years). Amyloid was located in subglottis (5), glottis (8), false vocal folds (8) and other supraglottic areas (5), in more than one laryngeal region (13) and bilaterally (12). Cold steel excision was used at the glottis; CO2 laser excision, sometimes assisted by microdebrider, at other laryngeal areas. Eleven patients needed revision surgery, ten within the first 4 years after surgical treatment. One patient needed his first revision surgery after 11 years. Five patients needed a second revision within 6 years after initial diagnosis. Two patients needed a third revision. Indications for first revision surgery were progression (8) with dysphonia (7), dyspnea (2), dysphagia (1), exclusion of malignancy (1), and aphonia (1). No patient developed systemic amyloidosis during follow-up. Although local progression of amyloid necessitates revision surgery once or twice in the first 4-6 years, progression slows down thereafter. Late progression, however, remains possible.
EMI / EMC Design for Class D Payloads (Resource Prospector / NIRVSS)
NASA Technical Reports Server (NTRS)
Forgione, Josh; Benton, Joshua Eric; Thompson, Sarah; Colaprete, Anthony
2015-01-01
EMI/EMC techniques are applied to a Class D instrument (NIRVSS) to achieve low noise performance and reduce risk of EMI/EMC testing failures and/or issues during system integration and test. Basic techniques are not terribly expensive or complex, but do require close coordination between electrical and mechanical staff early in the design process. Low-cost methods to test subsystems on the bench without renting an EMI chamber are discussed. This method was applied to the NIRVSS instrument and achieved improvements up to 59dB on conducted emissions measurements between hardware revisions.
NASA Astrophysics Data System (ADS)
Zou, Y.; Yang, C.; Guzman, N.; Delgado, J.; Mickler, P. J.; Horvoka, S.; Trevino, R.
2015-12-01
One concern related to GCS is possible risk of unintended CO2 leakage from the storage formations into overlying potable aquifers on underground sources of drinking water (USDW). Here we present a series of field tests conducted in an alluvial aquifer which is on a river terrace at The University of Texas Brackenridge Field Laboratory. Several shallow groundwater wells were completed to the limestone bedrock at a depth of 6 m and screened in the lower 3 m. Core sediments recovered from the shallow aquifer show that the sediments vary in grain size from clay-rich layers to coarse sandy gravels. Two main types of field tests were conducted at the BFL: single- (or double-) well push-pull test and pulse-like CO2 release test. A single- (or double-) well push-pull test includes three phases: the injection phase, the resting phase and pulling phase. During the injection phase, groundwater pumped from the shallow aquifer was stored in a tank, equilibrated with CO2 gasand then injected into the shallow aquifer to mimic CO2 leakage. During the resting phase, the groundwater charged with CO2 reacted with minerals in the aquifer sediments. During the pulling phase, groundwater was pumped from the injection well and groundwater samples were collected continuously for groundwater chemistry analysis. In such tests, large volume of groundwater which was charged with CO2 can be injected into the shallow aquifer and thus maximize contact of groundwater charged with CO2. Different than a single- (or double-) well push-pull test, a pulse-like CO2 release test for validating chemical sensors for CO2 leakage detection involves a CO2 release phase that CO2 gas was directly bubbled into the testing well and a post monitoring phase that groundwater chemistry was continuously monitored through sensors and/or grounder sampling. Results of the single- (or double-) well push-pull tests conducted in the shallow aquifer shows that the unintended CO2 leakage could lead to dissolution of carbonates and some silicates and mobilization of heavy metals from the aquifer sediments to groundwater, however, such mobilization posed no risks on groundwater quality at this site. The pulse-like tests have demonstrated it is plausible to use chemical sensors for CO2 leakage detection in groundwater.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-20
..., closures and coils, from graphic arts operations, from the provision of sampling and testing facilities... Provision of Sampling and Revised 03/21/01....... 05/31/01 Testing Facilities. AVAQMD 1168 Adhesive and... District (1) Rule 205, ``Provision of Sampling and Testing Facilities,'' revised on March 21, 2001...
NASA Astrophysics Data System (ADS)
Schroth, M. H.; Kleikemper, J.; Pombo, S. A.; Zeyer, J.
2002-12-01
In the past, studies on microbial communities in natural environments have typically focused on either their structure or on their metabolic function. However, linking structure and function is important for understanding microbial community dynamics, in particular in contaminated environments. We will present results of a novel combination of a hydrogeological field method (push-pull tests) with molecular tools and stable isotope analysis, which was employed to quantify anaerobic activities and associated microbial diversity in a petroleum-contaminated aquifer in Studen, Switzerland. Push-pull tests consisted of the injection of test solution containing a conservative tracer and reactants (electron acceptors, 13C-labeled carbon sources) into the aquifer anoxic zone. Following an incubation period, the test solution/groundwater mixture was extracted from the same location. Metabolic activities were computed from solute concentrations measured during extraction. Simultaneously, microbial diversity in sediment and groundwater was characterized by using fluorescence in situ hybridization (FISH), denaturing gradient gel electrophoresis (DGGE), as well as phospholipids fatty acid (PLFA) analysis in combination with 13C isotopic measurements. Results from DGGE analyses provided information on the general community structure before, during and after the tests, while FISH yielded information on active populations. Moreover, using 13C-labeling of microbial PLFA we were able to directly link carbon source assimilation in an aquifer to indigenous microorganisms while providing quantitative information on respective carbon source consumption.
NASA Astrophysics Data System (ADS)
Zeilfelder, Sarah; Hebig, Klaus; Ito, Narimitsu; Machida, Isao; Scheytt, Traugott; Marui, Atsunao
2013-04-01
What method is appropriate to investigate an aquifer when there is only one well available? A single well "push-pull" tracer test (PP Test) may be a suitable method in order to characterize an aquifer and to obtain information about the hydraulic and chemical properties when only one well is available for the investigations. In a PP test, a test solution that contains a known amount of solutes and a conservative tracer is injected into the aquifer ("push") and extracted afterwards ("pull"). Optionally, the test solution is flushed out of the well and the casing with untreated test solution with a so called "chaser" before being extracted. Also between the injection and the extraction phase a drifting time may be included. The breakthrough of the tracer during the extraction phase is measured and used for analyses and interpretation. In the last three years, several PP Test campaigns were conducted at two different test sites in Japan (Hebig et al. 2011, Zeilfelder et al. 2012). The aim was to investigate the applicability of the PP Test method in different geological settings and in different types of aquifers. The latest field campaign thus focussed on the question how variations of the setup are influencing the breakthrough curve of the PP Test in order to develop and enhance this method. Also the standardization of the PP Test was an aim of this study. During the campaign, a total of seven PP Tests were performed, while only single aspects of the setup were varied from test to test. The tests differed in injection and extraction rate, in the salinity of the injected test solution and in the use of a chaser solution. The general shapes of the breakthrough curves were similar and conclusions about the repeatability of the PP Test could be drawn. However, a sharp anomaly was observed in the breakthrough curve of one specific setup type. By repeating this PP test under the same boundary conditions, we were able to recreate the anomaly and could exclude any technical aspects as a source. In this version of the PP test higher salinized test solution was injected into the aquifer. There are several hypotheses that could explain the behavior of the breakthrough curves of the tracer in this test design. Of all the possibilities (like sorption processes, unexpected tracer reactions, inhomogeneities in the aquifer, influence of the well design), we assume that ion exchange processes and density driven flow are the main reasons for the repeatedly observed anomaly. References: Hebig, K.H., Ito, N., Scheytt, T.J. & Marui, A. (2011). Hydraulic and hydrochemical characterization of deep coastal sedimentary basins by single-well Push-Pull tests. GSA Annual Meeting, 9-12 October 2011, Minneapolis, USA. Zeilfelder, S., Ito, N., Marui, A., Hebig, K. & Scheytt, T. (2012). Push-Pull-Test und Tracer-Test in einem tiefen Grundwasserleiter in Kameoka, Japan. Kurzfassung in: Liedl, R., Burghardt, D., Simon, E., Reimann, T. & Kaufmann-Knoke (Hg.). Grundwasserschutz und Grundwassernutzung. Tagung der Fachsektion Hydrogeologie in der DGG (FH-DGG). 16. - 20. Mai 2012, Dresden. Kurfassungen der Vorträge und Poster. Schriftenreihe der DGG, Heft 78, S. 192.
2016-01-01
The aim of this study was to determine how representative wear scars of simulator-tested polyethylene (PE) inserts compare with retrieved PE inserts from total knee replacement (TKR). By means of a nonparametric self-organizing feature map (SOFM), wear scar images of 21 postmortem- and 54 revision-retrieved components were compared with six simulator-tested components that were tested either in displacement or in load control according to ISO protocols. The SOFM network was then trained with the wear scar images of postmortem-retrieved components since those are considered well-functioning at the time of retrieval. Based on this training process, eleven clusters were established, suggesting considerable variability among wear scars despite an uncomplicated loading history inside their hosts. The remaining components (revision-retrieved and simulator-tested) were then assigned to these established clusters. Six out of five simulator components were clustered together, suggesting that the network was able to identify similarities in loading history. However, the simulator-tested components ended up in a cluster at the fringe of the map containing only 10.8% of retrieved components. This may suggest that current ISO testing protocols were not fully representative of this TKR population, and protocols that better resemble patients' gait after TKR containing activities other than walking may be warranted. PMID:27597955
Streese-Kleeberg, Jan; Rachor, Ingke; Gebert, Julia; Stegmann, Rainer
2011-05-01
In order to optimise methane oxidation in landfill cover soils, it is important to be able to accurately quantify the amount of methane oxidised. This research considers the gas push-pull test (GPPT) as a possible method to quantify oxidation rates in situ. During a GPPT, a gas mixture consisting of one or more reactive gases (e.g., CH(4), O(2)) and one or more conservative tracers (e.g., argon), is injected into the soil. Following this, the mixture of injected gas and soil air is extracted from the same location and periodically sampled. The kinetic parameters for the biological oxidation taking place in the soil can be derived from the differences in the breakthrough curves. The original method of Urmann et al. (2005) was optimised for application in landfill cover soils and modified to reduce the analytical effort required. Optimised parameters included the flow rate during the injection phase and the duration of the experiment. 50 GPPTs have been conducted at different landfills in Germany during different seasons. Generally, methane oxidation rates ranged between 0 and 150 g m(soil air)(-3)h(-1). At one location, rates up to 440 g m(soil air)(-3)h(-1) were measured under particularly favourable conditions. The method is simple in operation and does not require expensive equipment besides standard laboratory gas chromatographs. Copyright © 2010 Elsevier Ltd. All rights reserved.
Smart, Jennifer I; Corey, Gordon Ralph; Stryjewski, Martin E; Wang, Whedy; Barriere, Steven L
2016-12-01
The broth microdilution method (BMD) for testing telavancin minimum inhibitory concentrations (MICs) was revised (rBMD) in 2014 to improve the accuracy, precision, and reproducibility of the testing method. The aim of this study was to determine the effect of the revised method on telavancin MIC values for Staphylococcus aureus (S. aureus) clinical isolates obtained from hospital-acquired pneumonia (HAP) patients. Isolates from patients who participated in the phase 3 Assessment of Telavancin for Treatment of HAP Studies were retested using the rBMD method. Retesting of 647 isolates produced a range of telavancin MIC values from 0.015 µg/mL to 0.12 µg/mL with MIC 50/90 values of 0.06/0.06 µg/mL for the total pool of samples. For methicillin-resistant S. aureus (MRSA), MIC 50/90 values were 0.06/0.12 µg/mL. These values are up to 4-fold lower than MIC 50/90 values obtained using the original method. These results were used in part to justify lowering the telavancin breakpoints. All tested isolates remained susceptible to telavancin at the revised susceptibility breakpoint of ≤0.12 µg/mL. Overall, the clinical cure rate for microbiologically evaluable telavancin-treated patients was 78% for S. aureus, 76% for patients with MRSA, and 79% for patients with isolates with reduced susceptibility to vancomycin (MIC ≥1 µg/mL). Results from the rBMD method support the in vitro potency of telavancin against S. aureus. ATTAIN (NCT00107952 and NCT00124020). Theravance Biopharma Antibiotics, Inc.
Targeted Drug Delivery in the Suprachoroidal Space by Swollen Hydrogel Pushing
Jung, Jae Hwan; Desit, Patcharin; Prausnitz, Mark R.
2018-01-01
Purpose The purpose is to target model drug particles to the posterior region of the suprachoroidal space (SCS) of the eye controlled via pushing by hydrogel swelling. Methods A particle formulation containing 1% hyaluronic acid (HA) with fluorescent polymer particles and a hydrogel formulation containing 4% HA were introduced in a single syringe as two layers without mixing, and injected sequentially into the SCS of the rabbit eye ex vivo and in vivo using a microneedle. Distribution of particles in the eye was determined by microscopy. Results During injection, the particle formulation was pushed toward the middle of the SCS by the viscous hydrogel formulation, but less than 12% of particles reached the posterior SCS. After injection, the particle formulation was pushed further toward the macula and optic nerve in the posterior SCS by hydrogel swelling and spreading. Heating the eye to 37°C, or injecting in vivo decreased viscosity and mechanical strength of the hydrogel, thereby allowing it to swell and flow further in the SCS. A high salt concentration (9% NaCl) in the hydrogel formulation further increased hydrogel swelling due to osmotic flow into the hydrogel. In this way, up to 76% of particles were delivered to the posterior SCS from an injection made near the limbus. Conclusions This study shows that model drug particles can be targeted to the posterior SCS by HA hydrogel swelling and pushing without particle functionalization or administering external driving forces. PMID:29677369
Singh, Anuja; Pati, Avik Kumar; Mishra, Ashok Kumar
2018-05-30
Push-pull organic fluorophores are important owing to their interesting optoelectronical properties. Here we report the photophysics of a new cross-conjugated push-pull enediynyl dye which belongs to an unexplored class of π-conjugated donor-acceptor systems. Two N,N-dimethylaniline moieties serve as donors and one pyrene ring functions as an acceptor via a common Y-shaped 'enediyne' bridge which facilitates the cross-electronic communication. The dye exhibits dual emission from locally excited (LE) and intramolecular charge transfer (ICT) states. While the LE emission is dominant in non-polar solvents, the ICT emission predominates in polar solvents. Time-resolved fluorescence decay experiments reveal a relatively shorter lifetime component (∼0.5-0.9 ns) belonging to an ICT state and a relatively longer lifetime species (∼1.6-2.8 ns) corresponding to the LE state. The strong ICT behavior of the dye is manifested through the huge red-shift (4166 cm-1) of the emission spectra from non-polar cyclohexane to polar N,N-dimethylformamide. In contrast to many small push-pull organic dyes, the LE and ICT states of the push-pull enediynyl dye follow the same excitation pathway. The dominant red-shifted ICT emission (∼550 nm) intensity of the dye in polar solvent decreases with a concomitant appearance of the blue-shifted LE emission (∼385 nm) upon prolonged exposure to photons. This opens up a new photophysical strategy of achieving high contrast two fluorescence color conversion from yellow to blue.
Graziele Magro, Miriam; Kuga, Milton Carlos; Regina Victorino, Keli; Vázquez-Garcia, Fernando Antonio; Aranda-Garcia, Arturo Javier; Faria-Junior, Norberto Batista; Faria, Gisele; Luis Shinohara, André
2014-01-01
The aim of the current study was to evaluate the presence of debris and smear layer after endodontic irrigation with different formulations of 2% chlorhexidine gluconate (CHX) and its effects on the push-out bond strength of an epoxy-based sealer on the radicular dentin. One hundred extracted human canines were prepared to F5 instrument and irrigated with 2.5% sodium hypochlorite and 17% ethylenediaminetetraacetic acid. Fifty teeth were divided into five groups (n = 10), according to the final irrigation protocol with different 2% CHX formulations: G1 (control, no final rinse irrigation), G2 (CHX solution), G3 (CHX gel), G4 (Concepsis), and G5 (CHX Plus). In sequence, the specimens were submitted to scanning electron microscopy (SEM) analysis, in the cervical-medium and medium-apical segments, to evaluate the presence of debris and smear layer. The other 50 teeth were treated equally to a SEM study, but with the root canals filled with an epoxy-based endodontic sealer and submitted to a push-out bond strength test, in the cervical, middle, and apical thirds. G2, G3, G4, and G5 provided higher precipitation of the debris and smear layer than G1 (P < 0.05), but these groups were similar to each other (P > 0.05), in both segments. The values obtained in the push out test did not differ between groups, independent of the radicular third (P > 0.05). The CHXs formulations caused precipitation of the debris and smear layer on the radicular dentin, but these residues did not interfere in the push-out bond strength of the epoxy-based sealer. Copyright © 2013 Wiley Periodicals, Inc.
2012-01-01
Background Previous studies demonstrated that stroke survivors have a limited capacity to increase their walking speeds beyond their self-selected maximum walking speed (SMWS). The purpose of this study was to determine the capacity of stroke survivors to reach faster speeds than their SMWS while walking on a treadmill belt or while being pushed by a robotic system (i.e. “push mode”). Methods Eighteen chronic stroke survivors with hemiplegia were involved in the study. We calculated their self-selected comfortable walking speed (SCWS) and SMWS overground using a 5-meter walk test (5-MWT). Then, they were exposed to walking at increased speeds, on a treadmill and while in “push mode” in an overground robotic device, the KineAssist, until they were tested at a speed that they could not sustain without losing balance. We recorded the time and number of steps during each trial and calculated gait speed, average cadence and average step length. Results Maximum walking speed in the “push mode” was 13% higher than the maximum walking speed on the treadmill and both were higher (“push mode”: 61%; treadmill: 40%) than the maximum walking speed overground. Subjects achieved these faster speeds by initially increasing both step length and cadence and, once individuals stopped increasing their step length, by only increasing cadence. Conclusions With post-stroke hemiplegia, individuals are able to walk at faster speeds than their SMWS overground, when provided with a safe environment that provides external forces that requires them to attempt dynamic stability maintenance at higher gait speeds. Therefore, this study suggests the possibility that, given the appropriate conditions, people post-stroke can be trained at higher speeds than previously attempted. PMID:23057500
... large muscles in the calf. These create the power needed to push off with the foot or go up on the toes. The large Achilles tendon connects these muscles to the heel. Heel pain is most often due to overuse of the ...
Rotationally Actuated Prosthetic Hand
NASA Technical Reports Server (NTRS)
Norton, William E.; Belcher, Jewell G., Jr.; Carden, James R.; Vest, Thomas W.
1991-01-01
Prosthetic hand attached to end of remaining part of forearm and to upper arm just above elbow. Pincerlike fingers pushed apart to degree depending on rotation of forearm. Simpler in design, simpler to operate, weighs less, and takes up less space.
Friction enhancement in concertina locomotion of snakes
Marvi, Hamidreza; Hu, David L.
2012-01-01
Narrow crevices are challenging terrain for most organisms and biomimetic robots. Snakes move through crevices using sequential folding and unfolding of their bodies in the manner of an accordion or concertina. In this combined experimental and theoretical investigation, we elucidate this effective means of moving through channels. We measure the frictional properties of corn snakes, their body kinematics and the transverse forces they apply to channels of varying width and inclination. To climb channels inclined at 60°, we find snakes use a combination of ingenious friction-enhancing techniques, including digging their ventral scales to double their frictional coefficient and pushing channel walls transversely with up to nine times body weight. Theoretical modelling of a one-dimensional n-linked crawler is used to calculate the transverse force factor of safety: we find snakes push up to four times more than required to prevent sliding backwards, presumably trading metabolic energy for an assurance of wall stability. PMID:22728386
Friction enhancement in concertina locomotion of snakes.
Marvi, Hamidreza; Hu, David L
2012-11-07
Narrow crevices are challenging terrain for most organisms and biomimetic robots. Snakes move through crevices using sequential folding and unfolding of their bodies in the manner of an accordion or concertina. In this combined experimental and theoretical investigation, we elucidate this effective means of moving through channels. We measure the frictional properties of corn snakes, their body kinematics and the transverse forces they apply to channels of varying width and inclination. To climb channels inclined at 60°, we find snakes use a combination of ingenious friction-enhancing techniques, including digging their ventral scales to double their frictional coefficient and pushing channel walls transversely with up to nine times body weight. Theoretical modelling of a one-dimensional n-linked crawler is used to calculate the transverse force factor of safety: we find snakes push up to four times more than required to prevent sliding backwards, presumably trading metabolic energy for an assurance of wall stability.
Outcome of prosthesis exchange for infected knee arthroplasty: the effect of treatment approach.
Jämsen, Esa; Stogiannidis, Ioannis; Malmivaara, Antti; Pajamäki, Jorma; Puolakka, Timo; Konttinen, Yrjö T
2009-02-01
Two-stage revision remains the gold standard in the treatment of infected knee arthroplasty. Lately, good long-term results of direct exchange arthroplasty have been reported. The purpose of this literature review is to compare the clinical outcome achieved with one-stage revision and two-stage revision with different types of spacers. A thorough systematic review of literature was undertaken to idenepsy reports on the treatment alternatives. Papers written in English or including an English abstract, published from 1980 through 2005, and reporting either the success rate in eradication of infection or the clinical status achieved were reviewed. 31 original articles describing the results of 154 one-stage exchange arthoplasties and of 926 two-stage exchange arthoplasties were included. The depth of detail in the description of materials and methods varied markedly, making it impossible to perform a meta-analysis. Instead, a descriptive review of the results is presented. With a follow-up of 12-122 months, the overall success rate in eradication of infection was 73-100% after one-stage revisions and 82-100% after two-stage revisions. Reinfection rates were the lowest in series where articulating cement spacers were used, though the follow-up was relatively short. Studies using articulating spacers reported the highest average postoperative ranges of motion. Otherwise, no correlations were observed between the clinical outcome and the length of follow-up, the type of revision, or the type of spacer. The clinical outcome (knee scores and range of motion) of the one-stage revisions was no different from that of the two-stage revisions. Two-stage exchange is an effective treatment. Mobile spacers may further improve the range of motion. More experience in one-stage revision is required in order to define its role in the management of infected knee arthroplasties.
2018-01-01
Objectives This study evaluated the effect of ultrasonic agitation of mineral trioxide aggregate (MTA), calcium silicate-based cement (CSC), and Sealer 26 (S26) on adaptation at the cement/dentin interface and push-out bond strength. Materials and Methods Sixty maxillary canines were divided into 6 groups (n = 10): MTA, S26, and CSC, with or without ultrasonic activation (US). After obturation, the apical portions of the teeth were sectioned, and retrograde cavities were prepared and filled with cement by hand condensation. In the US groups, the cement was activated for 60 seconds: 30 seconds in the mesio-distal direction and 30 seconds in the buccal-lingual direction, using a mini Irrisonic insert coupled with the ultrasound transducer. After the materials set, 1.5-mm thick sections were obtained from the apexes. The presence of gaps and the bond between cement and dentin were analyzed using low-vacuum scanning electron microscopy. Push-out bond strength was measured using a universal testing machine. Results Ultrasonic agitation increased the interfacial adaptation of the cements. The S26 US group showed a higher adaptation value than MTA (p < 0.05). US improved the push-out bond strength for all the cements (p < 0.05). Conclusions The US of retrograde filling cements enhanced the bond to the dentin wall of the root-end filling materials tested. PMID:29765903
Alcalde, Murilo Priori; Vivan, Rodrigo Ricci; Marciano, Marina Angélica; Duque, Jussaro Alves; Fernandes, Samuel Lucas; Rosseto, Mariana Bailo; Duarte, Marco Antonio Hungaro
2018-05-01
This study evaluated the effect of ultrasonic agitation of mineral trioxide aggregate (MTA), calcium silicate-based cement (CSC), and Sealer 26 (S26) on adaptation at the cement/dentin interface and push-out bond strength. Sixty maxillary canines were divided into 6 groups ( n = 10): MTA, S26, and CSC, with or without ultrasonic activation (US). After obturation, the apical portions of the teeth were sectioned, and retrograde cavities were prepared and filled with cement by hand condensation. In the US groups, the cement was activated for 60 seconds: 30 seconds in the mesio-distal direction and 30 seconds in the buccal-lingual direction, using a mini Irrisonic insert coupled with the ultrasound transducer. After the materials set, 1.5-mm thick sections were obtained from the apexes. The presence of gaps and the bond between cement and dentin were analyzed using low-vacuum scanning electron microscopy. Push-out bond strength was measured using a universal testing machine. Ultrasonic agitation increased the interfacial adaptation of the cements. The S26 US group showed a higher adaptation value than MTA ( p < 0.05). US improved the push-out bond strength for all the cements ( p < 0.05). The US of retrograde filling cements enhanced the bond to the dentin wall of the root-end filling materials tested.
Ward, Jeffery Kurt; Hastie, Peter A; Wadsworth, Danielle D; Foote, Shelby; Brock, Sheri J; Hollett, Nikki
2017-09-01
The purpose of this study was to determine the extent to which a sport education season of fitness could provide students with recommended levels of in-class moderate-to-vigorous physical activity (MVPA) while also increasing students' fitness knowledge and fitness achievement. One hundred and sixty-six 5th-grade students (76 boys, 90 girls) participated in a 20-lesson season called "CrossFit Challenge" during a 4-week period. The Progressive Aerobic Cardiovascular Endurance Run, push-ups, and curl-ups tests of the FITNESSGRAM® were used to assess fitness at pretest and posttest, while fitness knowledge was assessed through a validated, grade-appropriate test of health-related fitness knowledge (HRF). Physical activity was measured with Actigraph GT3X triaxial accelerometers. Results indicated a significant time effect for all fitness tests and the knowledge test. Across the entire season, the students spent an average of 54.5% of lesson time engaged in MVPA, irrespective of the type of lesson (instruction, free practice, or competition). The results suggest that configuring the key principles of sport education within a unit of fitness is an efficient model for providing students with the opportunity to improve fitness skill and HRF knowledge while attaining recommended levels of MVPA.
The societal costs of femoral neck fracture patients treated with internal fixation.
Zielinski, S M; Bouwmans, C A M; Heetveld, M J; Bhandari, M; Patka, P; Van Lieshout, E M M
2014-03-01
The study rationale was to provide a detailed overview of the costs for femoral neck fracture treatment with internal fixation in the Netherlands. Mean total costs per patient at 2-years follow-up were
Increased risk of revision of cementless stemmed total hip arthroplasty with metal-on-metal bearings
Pedersen, Alma B; Mäkelä, Keijo; Eskelinen, Antti; Havelin, Leif Ivar; Furnes, Ove; Kärrholm, Johan; Garellick, Göran; Overgaard, Søren
2015-01-01
Background and purpose Data from the national joint registries in Australia and England and Wales have revealed inferior medium-term survivorship for metal-on-metal (MoM) total hip arthroplasty (THA) than for metal-on-polyethylene (MoP) THA. Based on data from the Nordic Arthroplasty Register Association (NARA), we compared the revision risk of cementless stemmed THA with MoM and MoP bearings and we also compared MoM THA to each other. Patients and methods We identified 32,678 patients who were operated from 2002 through 2010 with cementless stemmed THA with either MoM bearings (11,567 patients, 35%) or MoP bearings (21,111 patients, 65%). The patients were followed until revision, death, emigration, or the end of the study period (December 31, 2011), and median follow-up was 3.6 (interquartile range (IQR): 2.4–4.8) years for MoM bearings and 3.4 (IQR: 2.0–5.8) years for MoP bearings. Multivariable regression in the presence of competing risk of death was used to assess the relative risk (RR) of revision for any reason (with 95% confidence interval (CI)). Results The cumulative incidence of revision at 8 years of follow-up was 7.0% (CI: 6.0–8.1) for MoM bearings and 5.1% (CI: 4.7–5.6) for MoP bearings. At 6 years of follow-up, the RR of revision for any reason was 1.5 (CI: 1.3–1.7) for MoM bearings compared to MoP bearings. The RR of revision for any reason was higher for the ASR (adjusted RR = 6.4, CI: 5.0–8.1), the Conserve Plus (adjusted RR = 1.7, CI: 1.1–2.5) and “other” acetabular components (adjusted RR = 2.4, CI: 1.5–3.9) than for MoP THA at 6 years of follow-up. Interpretation At medium-term follow-up, the survivorship for cementless stemmed MoM THA was inferior to that for MoP THA, and metal-related problems may cause higher revision rates for MoM bearings with longer follow-up. PMID:25715878
Liow, Ming Han Lincoln; Dimitriou, Dimitris; Tsai, Tsung-Yuan; Kwon, Young-Min
2016-12-01
Revision surgery of failed metal-on-metal (MoM) total hip arthroplasty (THA) for adverse tissue reaction (pseudotumor) can be challenging as a consequence of soft tissue and muscle necrosis. The aims of this study were to (1) report the revision outcomes of patients who underwent revision surgery for failed MoM hip arthroplasty due to symptomatic pseudotumor and (2) identify preoperative risk factors associated with revision outcomes. Between January 2011 and January 2013, a total of 102 consecutive large head MoM hip arthroplasties in 97 patients (male: 62, female: 35), who underwent revision surgery were identified from the database of a multidisciplinary referral center. At minimum follow-up of 2 years (range: 26-52 months), at least one complication had occurred in 14 of 102 revisions (14%). Prerevision radiographic loosening (P = .01), magnetic resonance imaging (MRI) findings of solid lesions with abductor deficiency on MRI (P < .001), and intraoperative grading of adverse tissue reactions (P = .05) were correlated with post-revision complications. The reoperation rate of revised MoM THA was 7% (7 of 102 hips). Implant survivorship was 88% at 3 years. Metal ion levels declined in most patients after removal of MoM articulation. Revision outcomes of revision surgery for failed MoM THA due to symptomatic pseudotumor demonstrated 14% complication rate and 7% re-revision rate at 30-month follow-up. Our study identified prerevision radiographic loosening, solid lesions/abductor deficiency on MRI, and high grade intraoperative tissue damage as risk factors associated with poorer revision outcomes. This provides clinically useful information for preoperative planning and perioperative counseling of MoM THA patients undergoing revision surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
Testing Fundamental Gravity with Interplanetary Laser Ranging
NASA Astrophysics Data System (ADS)
Turyshev, S. G.; Shao, M.; Hahn, I.
2018-02-01
Very accurate range measurements with the Interplanetary Laser Ranging Terminal (ILRT) will push high-precision tests of astrophysics/gravitation into a new regime. It could be used for navigation and investigations in planetary/lunar science.
Dyrhovden, Gro S; Fenstad, Anne M; Furnes, Ove; Gøthesen, Øystein
2016-12-01
Background and purpose - The long-term effects of computer-assisted surgery in total knee replacement (CAS) compared to conventionally operated knee replacement (CON) are still not clear. We compared survivorship and relative risk of revision in CAS and CON based on data from the Norwegian Arthroplasty Register. Patients and methods - We assessed primary total knee replacements without patellar resurfacing reported to the Norwegian Arthroplasty Register from 2005 through 2014. The 5 most used implants and the 3 most common navigation systems were included. The groups (CAS, n = 3,665; CON, n = 20,019) were compared using a Cox regression analysis adjusted for age, sex, ASA category, prosthesis brand, fixation method, previous surgery, and diagnosis with the risk of revision for any reason as endpoint. Secondary outcomes were reasons for revision and effects of prosthesis brand, fixation method, age (± 65 years), and hospital volume. Results - Prosthesis survival and risk of revision were similar for CAS and CON. CAS had significantly fewer revisions due to malalignment. Otherwise, no statistically significant difference was found between the groups in analyses of secondary outcomes. Mean operating time was 13 minutes longer in CAS. Interpretation - At 8 years of follow-up, CAS and CON had similar rates of overall revision, but CAS had fewer revisions due to malalignment. According to our findings, the benefits of CAS at medium-term follow-up are limited. Further research may identify subgroups that benefit from CAS, and it should also emphasize patient-reported outcomes.
Mohaddes, Maziar; Herberts, Peter; Malchau, Henrik; Johanson, Per-Erik; Kärrholm, Johan
2017-05-12
Bone impaction grafting is a biologically and mechanically appealing option in acetabular revision surgery, allowing restitution of the bone stock and restoration of the biomechanics. We analysed differences in proximal migration of the revision acetabular components when bone impaction grafting is used together with a cemented or an uncemented cup. 43 patients (47 hips), revised due to acetabular loosening and judged to have less than 50% host bone-implant contact were included. The hips were randomised to either an uncemented (n = 20) or a cemented (n = 27) revision cup. Radiostereometry and radiography was performed postoperatively, at 3 and 6 months, 1, 2, 3, 5, 7, 10 and 13 and 17 years postoperatively. Clinical follow-up was performed at 1, 2 and 5 years postoperatively and thereafter at the same interval as in the radiographic follow-up. There were no differences in the base line demographic data between the 2 groups. At the last follow-up (17 years) 14 hips (10 cemented, 4 uncemented) had been re-revised due to loosening. 3 additional cups (1 uncemented and 2 cemented) were radiographically loose. There was a higher early proximal migration in the cemented cups. Cups operated on with cement showed a higher early migration measured with RSA and also a higher number of late revisions. The reason for this is not known, but factors such as inclusion of cases with severe bone defects, use of smaller bone chips and issues related to the impaction technique might have had various degrees of influence.
Dyrhovden, Gro S; Fenstad, Anne M; Furnes, Ove; Gøthesen, Øystein
2016-01-01
Background and purpose The long-term effects of computer-assisted surgery in total knee replacement (CAS) compared to conventionally operated knee replacement (CON) are still not clear. We compared survivorship and relative risk of revision in CAS and CON based on data from the Norwegian Arthroplasty Register. Patients and methods We assessed primary total knee replacements without patellar resurfacing reported to the Norwegian Arthroplasty Register from 2005 through 2014. The 5 most used implants and the 3 most common navigation systems were included. The groups (CAS, n = 3,665; CON, n = 20,019) were compared using a Cox regression analysis adjusted for age, sex, ASA category, prosthesis brand, fixation method, previous surgery, and diagnosis with the risk of revision for any reason as endpoint. Secondary outcomes were reasons for revision and effects of prosthesis brand, fixation method, age (± 65 years), and hospital volume. Results Prosthesis survival and risk of revision were similar for CAS and CON. CAS had significantly fewer revisions due to malalignment. Otherwise, no statistically significant difference was found between the groups in analyses of secondary outcomes. Mean operating time was 13 minutes longer in CAS. Interpretation At 8 years of follow-up, CAS and CON had similar rates of overall revision, but CAS had fewer revisions due to malalignment. According to our findings, the benefits of CAS at medium-term follow-up are limited. Further research may identify subgroups that benefit from CAS, and it should also emphasize patient-reported outcomes. PMID:27775460
United States Air Force Civil Engineering Additive Manufacturing Applications: Tools and Jigs
designs for printing applications. The overall results push forward the Air Forces 3D printing knowledge while providing critical information for decision makers on this up and coming technology....the results indicate that 3Dscanning technology will reach a point within the next 5 years where it can help foster the rapid build-up of 3D CE asset
Nooh, Ahmed Mohamed; Abdeldayem, Hussein Mohammed; Ben-Affan, Othman
2017-05-01
The objective of this study was to assess effectiveness and safety of the reverse breech extraction approach in Caesarean section for obstructed labour, and compare it with the standard approach of pushing the fetal head up through the vagina. This randomised controlled trial included 192 women. In 96, the baby was delivered by the 'reverse breech extraction approach', and in the remaining 96, by the 'standard approach'. Extension of uterine incision occurred in 18 participants (18.8%) in the reverse breech extraction approach group, and 46 (47.9%) in the standard approach group (p = .0003). Two women (2.1%) in the reverse breech extraction approach group needed blood transfusion and 11 (11.5%) in the standard approach group (p = .012). Pyrexia developed in 3 participants (3.1%) in the reverse breech extraction approach group, and 19 (19.8%) in the standard approach group (p = .0006). Wound infection occurred in 2 women (2.1%) in the reverse breech extraction approach group, and 12 (12.5%) in the standard approach group (p = .007). Apgar score <7 at 5 minutes was noted in 8 babies (8.3%) in the reverse breech extraction approach group, and 21 (21.9%) in the standard approach group (p = .015). In conclusion, reverse breech extraction in Caesarean section for obstructed labour is an effective and safe alternative to the standard approach of pushing the fetal head up through the vagina.
Local ventilation solution for large, warm emission sources.
Kulmala, Ilpo; Hynynen, Pasi; Welling, Irma; Säämänen, Arto
2007-01-01
In a foundry casting line, contaminants are released from a large area. Casting fumes include both volatile and particulate compounds. The volatile fraction contains hydrocarbons, whereas the particulate fraction mostly comprises a mixture of vaporized metal fumes. Casting fumes lower the air quality in foundries. The design of local ventilation for the casting area is a challenging task, because of the large casting area and convection plumes from warm moulds. A local ventilation solution for the mould casting area was designed and dimensioned with the aid of computational fluid dynamic (CFD) calculations. According to the calculations, the most efficient solution was a push-pull ventilation system. The prototype of the push-pull system was built and tested in actual operation at the foundry. The push flow was generated by a free plane jet that blew across the 10 m wide casting area towards an exhaust hood on the opposite side of the casting lines. The capture efficiency of the prototype was determined by the tracer gas method. The measured capture efficiencies with push jet varied between 40 and 80%, depending on the distance between the source and the exhaust. With the aid of the push flow, the average capture efficiency was increased from 40 (without jet) to 60%.
Coil spring venting arrangement
McCugh, R.M.
1975-10-21
A simple venting device for trapped gas pockets in hydraulic systems is inserted through a small access passages, operated remotely, and removed completely. The device comprises a small diameter, closely wound coil spring which is pushed through a guide temporarily inserted in the access passage. The guide has a central passageway which directs the coil spring radially upward into the pocket, so that, with the guide properly positioned for depth and properly oriented, the coil spring can be pushed up into the top of the pocket to vent it. By positioning a seal around the free end of the guide, the spring and guide are removed and the passage is sealed.
Cellular solidification of transparent monotectics
NASA Technical Reports Server (NTRS)
Kaulker, W. F.
1986-01-01
Understanding how liquid phase particles are engulfed or pushed during freezing of a monotectic is addressed. The additional complication is that the solid-liquid interface is nonplanar due to constitutional undercooling. Some evidence of particle pushing where the particles are the liquid phase of the montectic was already observed. Cellular freezing of the succinonitrile-glycerol system also occurred. Only a few compositions were tested at that time. The starting materials were not especially pure so that cellular interface observed was likely due to the presence of unkown impurities, the major portion of which was water. Topics addressed include: the effort of modeling the particle pushing process using the computer, establishing an apparatus for the determination of phase diagrams, and the measurement of the temperature gradients with a specimen which will solidify on the temperature gradient microscope stage.
Bush, Shane S; Sweet, Jerry J; Bianchini, Kevin J; Johnson-Greene, Doug; Dean, Pamela M; Schoenberg, Mike R
2018-04-01
Neuropsychological tests undergo periodic revision intended to improve psychometric properties, normative data, relevance of stimuli, and ease of administration. In addition, new tests are developed to evaluate psychological and neuropsychological constructs, often purporting to improve evaluation effectiveness. However, there is limited professional guidance to neuropsychologists concerning the decision to adopt a revised version of a test and/or replace an older test with a new test purporting to measure the same or overlapping constructs. This paper describes ethical and professional issues related to the selection and use of older versus newer psychological and neuropsychological tests, with the goal of promoting appropriate test selection and evidence-based decision making. Ethical and professional issues were reviewed and considered. The availability of a newer version of a test does not necessarily render obsolete prior versions of the test for purposes that are empirically supported, nor should continued empirically supported use of a prior version of a test be considered unethical practice. Until a revised or new test has published evidence of improved ability to help clinicians to make diagnostic determinations, facilitate treatment, and/or assess change over time, the choice to delay adoption of revised or new tests may be viewed as reasonable and appropriate. Recommendations are offered to facilitate decisions about the adoption of revised and new tests. Ultimately, it is the responsibility of individual neuropsychologists to determine which tests best meet their patients' needs, and to be able to support their decisions with empirical evidence and sound clinical judgment.
ERIC Educational Resources Information Center
Plake, Barbara S.; Wise, Lauress L.
2014-01-01
With the 2014 publication of the 5th revision of the "Standards for Educational and Psychological Testing," the cochairs of the Joint Committee for the revision process were asked to consider the role and importance of the "Standards" for the educational testing community, and in particular for members of the National Council…
2007-05-01
Bioaugmentation of Source Areas Dover National Test Site, Dover, Delaware ESTCP Project Number ER-0008 May 2007 Revision 3.0 ER0008 ii...2007.05.24 Revision 3.0 TABLE OF CONTENTS Page 1. INTRODUCTION...ER0008 iii 2007.05.24 Revision 3.0 3.5 Testing and Evaluation Plan
Midterm results of Magnum large head metal-on-metal total hip arthroplasty.
Aguado-Maestro, I; Cebrián Rodríguez, E; Paredes Herrero, E; Brunie Vegas, F; Oñate Miranda, M; Fernández García, N; García Alonso, M
2018-06-11
We present the results of the prospective follow up of a sample of large head metal-metal total hip arthroplasty obtained after the safety alert regarding a higher incidence of revision of these implants. All patients implanted with the Recap-M2a-Magnum cup between 2008 and 2011 were included. They were prospectively reviewed recording Harris Hip Score, clinical symptoms of chromium or cobalt intoxication. Serum levels of these ions were requested as well as X-Rays and ultrasonography. An MRI was performed in the cases of positive ultrasonography. Twenty-six males with a mean age of 48.54 years [32-62, SD: 7.18] were included. An anterolateral approach and Bi-Metric (7) and F-40 (19) stems were used. Cephalic diameters ranged 42-52 (mode: 46) and the mean cup inclination was 39.35° [21-59°, SD: 9.78]. During follow-up (7.3 years [5.9-9.4; SD: .78]), 3 patients (11.5%) underwent revision (2 cases aseptic loosening, 1 pseudotumour). Mean time until revision was 5.4 years [3.1-8.0; SD: 2.48]. The accumulated survival probability was 88.5% (95% CI 76.3-100%). Harris Hip Score was 94.47 [66.5-100; SD: 8.94] and the patients showed no metallic intoxication symptoms. The levels of chromium were 1.88 mcg/dl [0.6-3.9] and cobalt 1,74 mcg/dl [0.5-5,6]. One pseudotumour was found in an asymptomatic patient, and small amounts of periarticular liquid were found in 5 patients (19.2%) DISCUSSION AND CONCLUSIONS: High revision rates are still found when follow up is extended due to aseptic loosening and pseudotumour formation. MRI might not be the most adequate test to study the complications of these prostheses. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
Does Shoe Collar Height Influence Ankle Joint Kinematics and Kinetics in Sagittal Plane Maneuvers?
Yang, Yang; Fang, Ying; Zhang, Xini; He, Junliang; Fu, Weijie
2017-01-01
The Objective of the study is to investigate the effects of basketball shoes with different collar heights on ankle kinematics and kinetics and athletic performance in different sagittal plane maneuvers. Twelve participants who wore high-top and low-top basketball shoes (hereafter, HS and LS, respectively) performed a weight-bearing dorsiflexion (WB-DF) maneuver, drop jumps (DJs), and lay-up jumps (LJs). Their sagittal plane kinematics and ground reaction forces were recorded using the Vicon motion capture system and Kistler force plates simultaneously. Moreover, ankle dorsiflexion and plantarflexion angles, moment, power, stiffness, and jump height were calculated. In the WB-DF test, the peak ankle dorsiflexion angle (p = 0.041) was significantly smaller in HS than in LS. Additionally, the peak ankle plantarflexion moment (p = 0.028) and power (p = 0.022) were significantly lower in HS than in LS during LJs but not during DJs. In both jumping maneuvers, no significant differences were found in the jump height or ankle kinematics between the two shoe types. According to the WB-DF test, increasing shoe collar height can effectively reduce the ankle range of motion in the sagittal plane. Although the HS did not restrict the flexion–extension performance of the ankle joint during two jumping maneuvers, an increased shoe collar height can reduce peak ankle plantarflexion moment and peak power during the push-off phase in LJs. Therefore, a higher shoe collar height should be used to circumvent effects on the partial kinetics of the ankle joint in the sagittal plane. Key points An increased shoe collar height effectively reduced ankle joint ROM in the sagittal plane in weight-bearing dorsiflexion maneuver. Shoe collar height did not affect sagittal plane ankle kinematics and had no effect on performance during realistic jumping. Shoe collar height can affect the ankle plantarflexion torque and peak power during the push-off phase in lay-up jump. PMID:29238255
Velimirovic, Milica; Tosco, Tiziana; Uyttebroek, Maarten; Luna, Michela; Gastone, Francesca; De Boer, Cjestmir; Klaas, Norbert; Sapion, Hans; Eisenmann, Heinrich; Larsson, Per-Olof; Braun, Juergen; Sethi, Rajandrea; Bastiaens, Leen
2014-08-01
A pilot injection test with guar gum stabilized microscale zerovalent iron (mZVI) particles was performed at test site V (Belgium) where different chlorinated aliphatic hydrocarbons (CAHs) were present as pollutants in the subsurface. One hundred kilograms of 56μm-diameter mZVI (~70gL(-1)) was suspended in 1.5m(3) of guar gum (~7gL(-1)) solution and injected into the test area. In order to deliver the guar gum stabilized mZVI slurry, one direct push bottom-up injection (Geoprobe) was performed with injections at 5 depths between 10.5 and 8.5m bgs. The direct push technique was preferred above others (e.g. injection at low flow rate via screened wells) because of the limited hydraulic conductivity of the aquifer, and to the large size of the mZVI particles. A final heterogeneous distribution of the mZVI in the porous medium was observed explicable by preferential flow paths created during the high pressure injection. The maximum observed delivery distance was 2.5m. A significant decrease in 1,1,1-TCA concentrations was observed in close vicinity of spots where the highest concentration of mZVI was observed. Carbon stable isotope analysis (CSIA) yielded information on the success of the abiotic degradation of 1,1,1-TCA and indicated a heterogeneous spatio-temporal pattern of degradation. Finally, the obtained results show that mZVI slurries stabilized by guar gum can be prepared at pilot scale and directly injected into low permeable aquifers, indicating a significant removal of 1,1,1-TCA. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Velimirovic, Milica; Tosco, Tiziana; Uyttebroek, Maarten; Luna, Michela; Gastone, Francesca; De Boer, Cjestmir; Klaas, Norbert; Sapion, Hans; Eisenmann, Heinrich; Larsson, Per-Olof; Braun, Juergen; Sethi, Rajandrea; Bastiaens, Leen
2014-08-01
A pilot injection test with guar gum stabilized microscale zerovalent iron (mZVI) particles was performed at test site V (Belgium) where different chlorinated aliphatic hydrocarbons (CAHs) were present as pollutants in the subsurface. One hundred kilograms of 56 μm-diameter mZVI (~ 70 g L- 1) was suspended in 1.5 m3 of guar gum (~ 7 g L- 1) solution and injected into the test area. In order to deliver the guar gum stabilized mZVI slurry, one direct push bottom-up injection (Geoprobe) was performed with injections at 5 depths between 10.5 and 8.5 m bgs. The direct push technique was preferred above others (e.g. injection at low flow rate via screened wells) because of the limited hydraulic conductivity of the aquifer, and to the large size of the mZVI particles. A final heterogeneous distribution of the mZVI in the porous medium was observed explicable by preferential flow paths created during the high pressure injection. The maximum observed delivery distance was 2.5 m. A significant decrease in 1,1,1-TCA concentrations was observed in close vicinity of spots where the highest concentration of mZVI was observed. Carbon stable isotope analysis (CSIA) yielded information on the success of the abiotic degradation of 1,1,1-TCA and indicated a heterogeneous spatio-temporal pattern of degradation. Finally, the obtained results show that mZVI slurries stabilized by guar gum can be prepared at pilot scale and directly injected into low permeable aquifers, indicating a significant removal of 1,1,1-TCA.
Cho, B K; Kim, Y M; Choi, S M; Park, H W; SooHoo, N F
2017-09-01
The aim of this prospective study was to evaluate the intermediate-term outcomes after revision anatomical ankle ligament reconstruction augmented with suture tape for a failed modified Broström procedure. A total of 30 patients with persistent instability of the ankle after a Broström procedure underwent revision augmented with suture tape. Of these, 24 patients who were followed up for more than two years were included in the study. There were 13 men and 11 women. Their mean age was 31.8 years (23 to 44). The mean follow-up was 38.5 months (24 to 56) The clinical outcome was assessed using the Foot and Ankle Outcome Score (FAOS) and the Foot and Ankle Ability Measure (FAAM) score. The stability of the ankle was assessed using stress radiographs. The mean FAOS and FAAM scores improved significantly to 87.5 (73 to 94) and 85.1 (70 to 95) points at final follow-up, respectively (p < 0.001). The mean angle of talar tilt and anterior talar translation improved significantly to 2.8° (0° to 6°) and 4.1 mm (2 to 7) at final follow-up, respectively (p < 0.001). Side to side comparison in stress radiographs at final follow-up showed no significant difference. The revision failed in one patient who underwent a further revision using allograft tendon. The revision modified Broström procedure augmented with suture tape is an effective form of treatment for recurrent instability of the ankle following a failed Broström procedure. This technique provides reliable stability and satisfactory clinical outcomes at intermediate-term follow-up. Cite this article: Bone Joint J 2017;99-B:1183-9. ©2017 The British Editorial Society of Bone & Joint Surgery.
Hernigou, Philippe; Dubory, Arnaud; Potage, Damien; Roubineau, François; Flouzat-Lachaniette, Charles Henri
2017-04-01
Patients with rheumatoid arthritis (RA) and osteoarthritis (OA) may require revision total knee replacement. Few studies have compared post-operative complications, results and risk of re-revision in RA and OA patients. Forty-five RA patients who had undergone revision TKA from 1998 to 2010 were selected and matched with 45 OA patients who had revision during the same period. Results of the use of a revision postero-stabilized implant in osteoarthritis were compared to results of its use in inflammatory arthritis. With a mean follow-up of ten years (range, 5-17 years) we determined differences in comorbidities, risk for peri-operative adverse events, functional and radiological results, and risk of subsequent re-revision, between patients suffering from OA versus RA. There were higher comorbidities, post-operative (<30 days) adverse events, and mortality at average ten years FU in RA than in OA patients. The mean overall changes in function scores were greater for the RA revision group when compared with the OA revision group. Taking steroids (Cox's regression, p = 0.001), and methotrexate or TNFα blockers (Cox's regression, p = 0.02) were not significant factors for radiolucent lines in RA and for loosening. At average ten years followup, patients with RA undergoing revision TKAs were not more likely to have a re-revision (4 among 45 patients; 9 %) than patients with OA undergoing revision in our department (7 patients; 15 %). Similar results for the knee were observed in these two forms of arthritis in spite of the fact that the initial local joint status and general health status are worse in inflammatory rheumatoid arthritis than in "degenerative" osteoarthritis. However, complications were more frequent with RA.
Revised model for the radiation force exerted by standing surface acoustic waves on a rigid cylinder
NASA Astrophysics Data System (ADS)
Liang, Shen; Chaohui, Wang
2018-03-01
In this paper, a model for the radiation force exerted by standing surface acoustic waves (SSAWs) on a rigid cylinder in inviscid fluids is extended to account for the dependence on the Rayleigh angle. The conventional model for the radiation force used in the SSAW-based applications is developed in plane standing waves, which fails to predict the movement of the cylinder in the SSAW. Our revised model reveals that, in the direction normal to the piezoelectric substrate on which the SSAW is generated, acoustic radiation force can be large enough to drive the cylinder even in the long-wavelength limit. Furthermore, the force in this direction can not only push the cylinder away, but also pull it back toward the substrate. In the direction parallel to the substrate, the equilibrium positions for particles can be actively tuned by changing Rayleigh angle. As an example considered in the paper, with the reduction of Rayleigh angle the equilibrium positions for steel cylinders in water change from pressure nodes to pressure antinodes. The model can thus be used in the design of SSAWs for particle manipulations.
Lenton, J P; van der Woude, L; Fowler, N; Nicholson, G; Tolfrey, K; Goosey-Tolfrey, V
2014-03-01
To compare the force application characteristics at various push frequencies of asynchronous (ASY) and synchronous (SYN) hand-rim propulsion, 8 able-bodied participants performed a separate sub-maximal exercise test on a wheelchair roller ergometer for each propulsion mode. Each test consisted of a series of 5, 4-min exercise blocks at 1.8 m · s-1 - initially at their freely chosen frequency (FCF), followed by four counter-balanced trials at 60, 80, 120 and 140% FCF. Kinetic data was obtained using a SMARTWheel, measuring forces and moments. The gross efficiency (GE) was determined as the ratio of external work done and the total energy expended. The ASY propulsion produced higher force measures for FRES, FTAN, rate of force development & FEF (P<0.05), while there was no difference in GE values (P=0.518). In pair-matched push frequencies (ASY80:SYN60, ASY100:SYN80, ASY120:SYN100 and ASY140:SYN120), ASY propulsion forces remained significantly higher (FRES, FTAN, rate of force development & FEF P<0.05), and there was no significant effect on GE (P=0.456). Both ASY and SYN propulsion demonstrate similar trends: changes in push frequency are accompanied by changes in absolute force even without changes in the gross pattern/trend of force application, FEF or GE. Matched push frequencies continue to produce significant differences in force measures but not GE. This suggests ASY propulsion is the predominant factor in force application differences. The ASY would appear to offer a kinetic disadvantage to SYN propulsion and no physiological advantage under current testing conditions. © Georg Thieme Verlag KG Stuttgart · New York.
One leg lateral jumps - a new test for team players evaluation.
Taboga, P; Sepulcri, L; Lazzer, S; De Conti, D; Di Prampero, P E
2013-10-01
We assessed the subject's capacity to accelerate himself laterally in monopodalic support, a crucial ability in several team sports, on 22 athletes, during series of 10 subsequent jumps, between two force platforms at predetermined distance. Vertical and horizontal accelerations of the Centre of Mass (CM), contact and flight times were measured by means of force platforms and the Optojump-System®. Individual mean horizontal and vertical powers and their sum (total power) ranged between 7 and 14.5 W/kg. "Push angle", i.e., the angle with the horizontal along which the vectorial sum of all forces is aligned, was calculated from the ratio between vertical and horizontal accelerations: it varied between 38.7 and 49.4 deg and was taken to express the subject technical ability. The horizontal acceleration of CM, indirectly estimated as a function of subject's mass, contact and flight times, was essentially equal to that obtained from force platforms data. Since the vertical displacement can be easily obtained from flight and contact times, this allowed us to assess the Push angle from Optojump data only. The power developed during a standard vertical jump was rather highly correlated with that developed during the lateral jumps for right (R=0.80, N.=12) and left limb (R=0.72, N.=12), but not with the push angle for right (R=0.31, N.=12) and left limb (R=-0.43, N.=12). Hence standard tests cannot be utilised to assess technical ability. Lateral jumps test allows the coach to evaluate separately maximal muscular power and technical ability of the athlete, thus appropriately directing the training program: the optimum, for a team-sport player being high power and low push-angle, that is: being "powerful" and "efficient".
The Development of Statistics Textbook Supported with ICT and Portfolio-Based Assessment
NASA Astrophysics Data System (ADS)
Hendikawati, Putriaji; Yuni Arini, Florentina
2016-02-01
This research was development research that aimed to develop and produce a Statistics textbook model that supported with information and communication technology (ICT) and Portfolio-Based Assessment. This book was designed for students of mathematics at the college to improve students’ ability in mathematical connection and communication. There were three stages in this research i.e. define, design, and develop. The textbooks consisted of 10 chapters which each chapter contains introduction, core materials and include examples and exercises. The textbook developed phase begins with the early stages of designed the book (draft 1) which then validated by experts. Revision of draft 1 produced draft 2 which then limited test for readability test book. Furthermore, revision of draft 2 produced textbook draft 3 which simulated on a small sample to produce a valid model textbook. The data were analysed with descriptive statistics. The analysis showed that the Statistics textbook model that supported with ICT and Portfolio-Based Assessment valid and fill up the criteria of practicality.
Reversing one's fortune by pushing away bad luck.
Zhang, Yan; Risen, Jane L; Hosey, Christine
2014-06-01
Across cultures, people try to "undo" bad luck with superstitious rituals such as knocking on wood, spitting, or throwing salt. We suggest that these rituals reduce the perceived likelihood of anticipated negative outcomes because they involve avoidant actions that exert force away from one's representation of self, which simulates the experience of pushing away bad luck. Five experiments test this hypothesis by having participants tempt fate and then engage in avoidant actions that are either superstitious (Experiment 1, knocking on wood) or nonsuperstitious (Experiments 2-5, throwing a ball). We find that participants who knock down (away from themselves) or throw a ball think that a jinxed negative outcome is less likely than participants who knock up (toward themselves) or hold a ball. Experiments 3 and 4 provide evidence that after tempting fate, engaging in an avoidant action leads to less clear mental representations for the jinxed event, which, in turn, leads to lower perceived likelihoods. Finally, we demonstrate that engaging in an avoidant action-rather than creating physical distance-is critical for reversing the perceived effect of the jinx. Although superstitions are often culturally defined, the underlying psychological processes that give rise to them may be shared across cultures. PsycINFO Database Record (c) 2014 APA, all rights reserved.
NASA Technical Reports Server (NTRS)
Miller, Sandi G.; Williams, Tiffany S.; Baker, James S.; Sola, Francisco; Lebron-Colon, Marisabel; McCorkle, Linda S.; Wilmoth, Nathan G.; Gaier, James; Chen, Michelle; Meador, Michael A.
2014-01-01
The inherent strength of individual carbon nanotubes offers considerable opportunity for the development of advanced, lightweight composite structures. Recent work in the fabrication and application of carbon nanotube (CNT) forms such as yarns and sheets has addressed early nanocomposite limitations with respect to nanotube dispersion and loading; and has pushed the technology toward structural composite applications. However, the high tensile strength of an individual CNT has not directly translated to macro-scale CNT forms where bulk material strength is limited by inter-tube electrostatic attraction and slippage. The focus of this work was to assess post processing of CNT sheet and yarn to improve the macro-scale strength of these material forms. Both small molecule functionalization and e-beam irradiation was evaluated as a means to enhance tensile strength and Youngs modulus of the bulk CNT material. Mechanical testing results revealed a tensile strength increase in CNT sheets by 57 when functionalized, while an additional 48 increase in tensile strength was observed when functionalized sheets were irradiated; compared to unfunctionalized sheets. Similarly, small molecule functionalization increased yarn tensile strength up to 25, whereas irradiation of the functionalized yarns pushed the tensile strength to 88 beyond that of the baseline yarn.
The infrared spectrograph during the SIRTF pre-definition phase
NASA Technical Reports Server (NTRS)
Houck, James R.
1988-01-01
A test facility was set up to evaluate back-illuminated impurity band detectors constructed for an infrared spectrograph to be used on the Space Infrared Telescope Facility (SIRTF). Equipment built to perform the tests on these arrays is described. Initial tests have been geared toward determining dark current and read noise for the array. Four prior progress reports are incorporated into this report. They describe the first efforts in the detector development and testing effort; testing details and a new spectrograph concept; a discussion of resolution issues raised by the new design; management activities; a review of computer software and testing facility hardware; and a review of the preamplifier constructed as well as a revised schematic of the detector evaluation facility.
Relationships between selected muscle endurance tasks and gender.
Laughlin, Neil T; Busk, Patricia L
2007-05-01
The purpose of this research was to examine possible relationships between selected muscle endurance tasks and gender. Until 1990, girls' and women's programs infrequently contained activities such as sit-ups, push-ups, pull-ups, and exercises with resistance equipment. This lack of exposure may have, in turn, resulted in much poorer performance than men when examined in experimental settings. The results of a discriminant analysis indicated that the women (n = 31) in this study did not differ from men (n = 31) in the mean number of sit-ups, modified push-ups, and leg adductions performed, but that the men performed more lateral arm raises than the women (p < 0.05). When the influence of the age, height, and weight of the subjects (mean +/- SD; 24.13 +/- 7.50 years, 173.05 +/- 8.77 cm, 76.34 +/- 13.01 kg for men; 26.61 +/- 11.12 years, 161.82 +/- 6.47 cm, 58.89 +/- 10.91 kg for women) was examined, there were only small changes in the structure of the discriminant function generated in the first analysis. These findings should be approached with caution because of possible limitations related to the size and representativeness of the sample and lack of measurement equipment such as video cameras. The fact that the pattern of results in this study differed somewhat from patterns in earlier research may indicate that the findings in this study are: (a) a random result or comparison anomaly related to characteristics specific to this convenience sample of women and men or (b) suggestive that differences between women and men in the tests chosen may be representative of changes that are beginning to occur in the degree of differences between men and women in college resistance training or other fitness-related classes. Practical applications of the results of this study for teachers of resistance training or fitness-related classes in secondary school, college, and adult recreation might be that fitness programs should be individualized to meet needs specific to each student and that coeducational classes and programs should be expanded, especially offerings of fitness-related activities.
Mathew, Vinod Babu; Ramachandran, S; Indira, R; Shankar, P
2011-01-01
Background: Dental amalgam is the primary direct posterior restorative material used worldwide, but it have certain shortcomings due to the lack of adhesiveness to the cavity. The introduction of the concept of bonded amalgam helped improve the use of amalgam as a restorative material. Aim: Evaluation of the comparative push-out shear bond strength of four types of conventional glass ionomers used to bond amalgam to tooth in simulated class I situations. Materials and Methods: Four chemical cure glass ionomers are used: GC Fuji I, GC Fuji II, GC Fuji III and GC Fuji VII, and are compared with unbonded amalgam. The push-out bond strength was tested using the Instron Universal Testing Machine at a crosshead speed of 0.5 mm/min. Statistical Analysis: One-way ANOVA and post hoc Bonferroni tests were used to analyze the data. Results: The results showed that the use of glass ionomer to bond amalgam resulted in an increase in the bond strength of amalgam. The Type VII glass ionomer showed the highest bond strength in comparison with the other glass ionomers. Conclusions: Conventional glass ionomer bonds to amalgam and shows a beneficial increase in the bond strength of the restoration in comparison with unbonded amalgam. PMID:22144798
Lachance, Chantelle C; Korall, Alexandra M B; Russell, Colin M; Feldman, Fabio; Robinovitch, Stephen N; Mackey, Dawn C
2018-09-01
Purpose-designed compliant flooring and carpeting have been promoted as a means for reducing fall-related injuries in high-risk environments, such as long-term care. However, it is not known whether these surfaces influence the forces that long-term care staff exert when pushing residents in wheelchairs. We studied 14 direct-care staff who pushed a loaded wheelchair instrumented with a triaxial load cell to test the effects on hand force of flooring overlay (vinyl versus carpet) and flooring subfloor (concrete versus compliant rubber [brand: SmartCells]). During straight-line pushing, carpet overlay increased initial and sustained hand forces compared to vinyl overlay by 22-49% over a concrete subfloor and by 8-20% over a compliant subfloor. Compliant subflooring increased initial and sustained hand forces compared to concrete subflooring by 18-31% when under a vinyl overlay. In contrast, compliant flooring caused no change in initial or sustained hand forces compared to concrete subflooring when under a carpet overlay. Copyright © 2018 Elsevier Ltd. All rights reserved.
Chruscicki, Adam; Badke, Katherin; Peddie, David; Small, Serena; Balka, Ellen; Hohl, Corinne M
2016-01-01
Adverse drug events (ADEs), harmful unintended consequences of medication use, are a leading cause of hospital admissions, yet are rarely documented in a structured format between care providers. We describe pilot-testing structured ADE documentation fields prior to integration into an electronic medical record (EMR). We completed a qualitative study at two Canadian hospitals. Using data derived from a systematic review of the literature, we developed screen mock-ups for an ADE reporting platform, iteratively revised in participatory workshops with diverse end-user groups. We designed a paper-based form reflecting the data elements contained in the mock-ups. We distributed them to a convenience sample of clinical pharmacists, and completed ethnographic workplace observations while the forms were used. We reviewed completed forms, collected feedback from pharmacists using semi-structured interviews, and coded the data in NVivo for themes related to the ADE form. We completed 25 h of clinical observations, and 24 ADEs were documented. Pharmacists perceived the form as simple and clear, with sufficient detail to capture ADEs. They identified fields for omission, and others requiring more detail. Pharmacists encountered barriers to documenting ADEs including uncertainty about what constituted a reportable ADE, inability to complete patient follow-up, the need for inter-professional communication to rule out alternative diagnoses, and concern about creating a permanent record. Paper-based pilot-testing allowed planning for important modifications in an ADE documentation form prior to implementation in an EMR. While paper-based piloting is rarely reported prior to EMR implementations, it can inform design and enhance functionality. Piloting with other groups of care providers and in different healthcare settings will likely lead to further revisions prior to broader implementations.
Long-term follow-up of shoulder hemiarthroplasty for glenohumeral osteoarthritis.
Levine, William N; Fischer, Charla R; Nguyen, Duong; Flatow, Evan L; Ahmad, Christopher S; Bigliani, Louis U
2012-11-21
There is major controversy surrounding the use of hemiarthroplasty as compared with total shoulder arthroplasty for glenohumeral osteoarthritis, and long-term clinical outcomes of hemiarthroplasty are lacking. Of a cohort of thirty patients (thirty-one shoulders) who were treated with hemiarthroplasty for glenohumeral osteoarthritis and followed longitudinally at our institution, twenty-five were available for long-term follow-up; five died, and one refused to participate. Three of the five patients who died had revision arthroplasty before death, and the data from those three were therefore included in the final follow-up (final follow-up data therefore included twenty-seven patients and twenty-eight shoulders). Follow-up through phone conversations and postal mail surveys included the following: Short Form-36, American Shoulder and Elbow Surgeons (ASES) shoulder outcome score, EuroQol, Simple Shoulder Test, modified Neer Score, and a unique, validated self-administered range-of-motion questionnaire. Correlations between clinical outcome and age, type of glenoid wear, and cause of osteoarthritis were determined. The average follow-up was 17.2 years (range, thirteen to twenty-one years). There were eight revisions (three of fifteen shoulders with concentric glenoids, and five of sixteen shoulders with eccentric glenoids). For those shoulders not revised, the average ASES score was 70.54 (range, 36.67 to 91.67). Overall, active shoulder forward elevation and external rotation with the arm at 90° of abduction increased from 104° preoperatively to 141.8° (range, 45° to 180°) and 20.7° to 61.0° (range, 30° to 90°), respectively (p < 0.05), at the time of final follow-up. Of those who required revision arthroplasty, the average patient age at the time of the index procedure was 51.0 years (range, twenty-six to eighty-one years), while those not requiring revision averaged 57.1 years (range, twenty-seven to sixty-three years). The overall Neer satisfaction rating was 25%. The average Neer score and Neer rating for unrevised cases were significantly higher for concentric glenoid wear compared with eccentric glenoid wear (p = 0.015 and p = 0.001, respectively). Patients who had concentric glenoid wear had higher EuroQol scores (p = 0.020). The average Neer scores were 65.29 (range, forty-seven to seventy-eight) for primary osteoarthritis and 54.46 (range, forty to seventy-seven) for secondary osteoarthritis (p = 0.036). Only 25% of patients with glenohumeral osteoarthritis treated with shoulder hemiarthroplasty are satisfied with their outcome at an average of seventeen years after the operation. Patients with concentric glenoid wear and primary osteoarthritis have better outcomes than those with eccentric glenoid wear and secondary osteoarthritis do, but patients in both groups experienced deterioration of results over time. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
ERIC Educational Resources Information Center
Maeda, Yukiko; Yoon, So Yoon
2016-01-01
We investigated the extent to which the observed gender differences in mental rotation ability among the 2,468 freshmen studying engineering at a Midwest public university attributed to the gender bias of a test. The Revised Purdue Spatial Visualization Tests: Visualization of Rotations (Revised PSVT:R) is a spatial test frequently used to measure…
Aryanto, Kadek Y E; Broekema, André; Oudkerk, Matthijs; van Ooijen, Peter M A
2012-01-01
To present an adapted Clinical Trial Processor (CTP) test set-up for receiving, anonymising and saving Digital Imaging and Communications in Medicine (DICOM) data using external input from the original database of an existing clinical study information system to guide the anonymisation process. Two methods are presented for an adapted CTP test set-up. In the first method, images are pushed from the Picture Archiving and Communication System (PACS) using the DICOM protocol through a local network. In the second method, images are transferred through the internet using the HTTPS protocol. In total 25,000 images from 50 patients were moved from the PACS, anonymised and stored within roughly 2 h using the first method. In the second method, an average of 10 images per minute were transferred and processed over a residential connection. In both methods, no duplicated images were stored when previous images were retransferred. The anonymised images are stored in appropriate directories. The CTP can transfer and process DICOM images correctly in a very easy set-up providing a fast, secure and stable environment. The adapted CTP allows easy integration into an environment in which patient data are already included in an existing information system.
Sankey, Eric W; Goodwin, C Rory; Jusué-Torres, Ignacio; Elder, Benjamin D; Hoffberger, Jamie; Lu, Jennifer; Blitz, Ari M; Rigamonti, Daniele
2016-05-01
OBJECT Endoscopic third ventriculostomy (ETV) is the treatment of choice for obstructive hydrocephalus; however, the success of ETV in patients who have previously undergone shunt placement remains unclear. The present study analyzed 103 adult patients with aqueductal stenosis who underwent ETV for obstructive hydrocephalus and evaluated the effect of previous shunt placement on post-ETV outcomes. METHODS This study was a retrospective review of 151 consecutive patients who were treated between 2007 and 2013 with ETV for hydrocephalus. One hundred three (68.2%) patients with aqueductal stenosis causing obstructive hydrocephalus were included in the analysis. Postoperative ETV patency and aqueductal and cisternal flow were assessed by high-resolution, gradient-echo MRI. Post-ETV Mini-Mental State Examination, Timed Up and Go, and Tinetti scores were compared with preoperative values. Univariate and multivariate analyses were performed comparing the post-ETV outcomes in patients who underwent a primary (no previous shunt) ETV (n = 64) versus secondary (previous shunt) ETV (n = 39). RESULTS The majority of patients showed significant improvement in symptoms after ETV; however, no significant differences were seen in any of the quantitative tests performed during follow-up. Symptom recurrence occurred in 29 (28.2%) patients after ETV, after a median of 3.0 (interquartile range 0.8-8.0) months post-ETV failure. Twenty-seven (26.2%) patients required surgical revision after their initial ETV. Patients who received a secondary ETV had higher rates of symptom recurrence (p = 0.003) and surgical revision (p = 0.003), particularly in regard to additional shunt placement/revision post-ETV (p = 0.005). These differences remained significant after multivariate analysis for both symptom recurrence (p = 0.030) and surgical revision (p = 0.043). CONCLUSIONS Patients with obstructive hydrocephalus due to aqueductal stenosis exhibit symptomatic improvement after ETV, with a relatively low failure rate. Patients with a primary history of shunt placement who undergo ETV as a secondary intervention are at increased risk of symptom recurrence and need for surgical revision post-ETV.
2008-06-01
2-1 PART 3 - TEST EQUIPMENT 1. Semitrailer, flatbed , breakbulk/container transporter, 34 ton Model #: M872A1 Manufactured by Heller Truck Body... LAMINATING DUNNAGE. ADDITIONALLY, THE NAILING PATTERN FOR AN UP- DA39 PALLET UNITS CENTERED ON TOP OF PRIOR DA39 PALLET UNITS, PER PIECE OF LAMINATED ...ai FT (APPWO HEADER I" X V’ X 7-4- (AS RECID, 1 SHOWYN). LAMINATE EACH HEADER TO PREVIOUS HEADER W/9-10d NAILS. HEADER 2" x 8" x r-" (AS RECID, 3 SHOWN
Antonio Sainz, José; Borrero, Carlota; Aquise, Adriana; García-Mejido, José Antonio; Gutierrez, Laura; Fernández-Palacín, Ana
2016-10-01
Our aim is to evaluate the capacity of intrapartum translabial ultrasound (ITU) with pushing in the prediction of difficulty of fetal extraction in vacuum assisted deliveries. Prospective, observational study performed (2/2015-8/2015) on 75 nulliparous women, ≥37 weeks with singleton pregnancies at full dilatation who had ITU-with-pushing performed, previous to vacuum-placement for fetal extraction. Working on the translabial sagittal-plane, we assessed: Angle-Progression (AoP), Progression-Distance (PD) and Head-Direction (HD); in the axial plane we evaluated: Midline-Angle (MLA) and Head-Perineum-Distance (HPD). Vacuum extractions were classified as easy-difficulty (ED) (≤3 vacuum-pulls), difficult-unsuccessful (DD) (>3 vacuum-pulls). We did not assess occipito-posterior-presentations. Seventy nulliparous were studied (44-ED,26-DD). We observed no differences in obstetric, neonatal or intrapartum characteristics between the two study groups, with the following exceptions: newborn weight (3272 ± 438 g versus 3540 ± 372 g; p = 0.011) and number of vacuum-pulls (1.4-ED-vs-4.4-DD; p < 0.0005). AoP-pushing was 143.9° ± 14.6° in ED and 115.1°± 12.9° in DD (p < 0.0005); Head-Up was 79.5% versus 38.4% (p < 0.0005); PD-Pushing was 42.7 ± 11.3 mm versus 30.4 ± 9.8 mm (p < 0.0005); MLA-Pushing was 27.6°± 26.6° versus 57.5°±26.5°(p=0.025); HPD-Pushing was 40.8 ± 10.0 mm versus 47.4 ± 10.9 mm (p = 0.039). We identified that the presence of an AoP-Pushing > 128° predicts an Easy-Vacuum-Delivery (≤3 Vacuum-Pulls) in >85% of cases (Sen 80%-FPR 9.3%).
Mohaddes, Maziar; Rolfson, Ola; Kärrholm, Johan
2015-02-01
The use of trabecular metal (TM) cups in revision surgery has increased worldwide during the last decade. Since the introduction of the TM cup in Sweden in 2006, this design has gradually replaced other uncemented designs used in Sweden. According to data from the Swedish Hip Arthroplasty Register (SHAR) in 2012, one-third of all uncemented first-time cup revisions were performed using a TM cup. We compared the risk of reoperation and re-revision for TM cups and the 2 other most frequently used cup designs in acetabular revisions reported to the SHAR. The hypothesis was that the performance of TM cups is as good as that of established designs in the short term. The study population consisted of 2,384 patients who underwent 2,460 revisions during the period 2006 through 2012. The most commonly used cup designs were the press-fit porous-coated cup (n = 870), the trabecular metal cup (n = 805), and the cemented all-polyethylene cup (n = 785). 54% of the patients were female, and the median age at index revision was 72 (19-95) years. Reoperation was defined as a second surgical intervention, and re-revision-meaning exchange or removal of the cup-was used as endpoint. The mean follow-up time was 3.3 (0-7) years. There were 215 reoperations, 132 of which were re-revisions. The unadjusted and adjusted risk of reoperation or re-revision was not significantly different for the TM cup and the other 2 cup designs. Our data support continued use of TM cups in acetabular revisions. Further follow-up is necessary to determine whether trabecular metal cups can reduce the re-revision rate in the long term, compared to the less costly porous press-fit and cemented designs.
Hightower, Charles D; Hightower, Lisa S; Tatman, Penny J; Morgan, Patrick M; Gioe, Terence; Singh, Jasvinder A
2016-08-24
Most patients have favorable outcomes after primary total knee arthroplasty (TKA). Well-validated methods to predict the risk of poor outcomes have not been developed or implemented. Several patients have annual clinic visits despite well-funcitoning TKA, as a routine practice, to detect early failure requiring revision surgery. It is not known whether assessment of pain and function can be used as a predictive tool for early failure and revision to guide practice. Our objective was to determine whether pain and function can predict revision after TKA. We retrospectively studied data from a large prospectively gathered TKA registry to examine changes in outcome scores for primary TKAs undergoing revision compared to those not requiring revision to determine the factors that are predictive for revision. Of the 1,012 patients, 721 had had a single-sided primary TKA and had American Knee Society (AKS) Scores for three or more visits. 46 patients underwent revision, 23 acutely (fracture, traumatic component failure or acute infection) and 23 for latent causes (late implant loosening, progressive osteolysis, or pain and indolent infection). Mean age was 70 years for the non-revision patients, and 64 years for those revised. Both AKS Clinical and AKS Function Scores for non-revised patients were higher than in revision patients, higher in acute revision compared to latent revision patients. Significant predictors of revision surgery were preoperative, 3- and 15-month postoperative AKS Clinical Scores and 3-month AKS Function Scores. At 15-month post-TKA, a patient with a low calculated probability of revision, 32 % or less, was unlikely to require revision surgery with a negative predictive value of 99 %. Time dependent interval evaluation post-TKA with the AKS outcome scores may provide the ability to assign risk of revision to patients at the 15-month follow-up visit. If these findings can be replicated using a patient-reported measure, a virtual follow-up with patient-reported outcomes and X-ray review may be an alternative to clinic visit for patients doing well.
Zhang, Ling; Huang, Li; Xiong, Yu; Fang, Ming; Chen, Ji-Hua; Ferrari, Marco
2008-06-01
The effect of post-space treatment on the retention of fiber posts in different root regions was evaluated using two self-etching systems. Post spaces were prepared in extracted premolars and then the root canals were subjected to one of the following post-space treatments: (i) water irrigation (control); (ii) etching with 35% phosphoric acid for 30 s; (iii) irrigation with 17% EDTA followed by 5.25% sodium hypochlorite (NaOCl); and (iv) ultrasonic agitation associated with 17% EDTA and 5.25% NaOCl irrigating solutions. The dentin surfaces were examined under scanning electron microscopy (SEM) after different post-space treatments. Fiber posts were then luted in the treated roots using resin cement with either Clearfil SE Bond or Clearfil DC Bond, and the thin-slice push-out test was performed. Scanning electron microscopy showed that all the post-space treatments tested were effective in removal of the smear layer of debris, or sealer/gutta-percha remnants, on the root canal. The apical push-out strength was affected by post-space treatment. Both 35% phosphoric acid etching and ultrasonic agitation in combination with EDTA/NaOCl irrigation improved the apical push-out strength of the fiber post, regardless of the type of self-etching system. A solo irrigation with an EDTA/NaOCl solution resulted in a lower apical push-out strength compared with the other two experimental groups.
Additive manufactured push-fit implant fixation with screw-strength pull out.
van Arkel, Richard J; Ghouse, Shaaz; Milner, Piers E; Jeffers, Jonathan R T
2017-10-11
Additive manufacturing offers exciting new possibilities for improving long-term metallic implant fixation in bone through enabling open porous structures for bony ingrowth. The aim of this research was to investigate how the technology could also improve initial fixation, a precursor to successful long-term fixation. A new barbed fixation mechanism, relying on flexible struts was proposed and manufactured as a push-fit peg. The technology was optimized using a synthetic bone model and compared with conventional press-fit peg controls tested over a range of interference fits. Optimum designs, achieving maximum pull-out force, were subsequently tested in a cadaveric femoral condyle model. The barbed fixation surface provided more than double the pull-out force for less than a third of the insertion force compared to the best performing conventional press-fit peg (p < 0.001). Indeed, it provided screw-strength pull out from a push-fit device (1,124 ± 146 N). This step change in implant fixation potential offers new capabilities for low profile, minimally invasive implant design, while providing new options to simplify surgery, allowing for one-piece push-fit components with high levels of initial stability. © 2017 The Authors. Journal of Orthopaedic Research Published by WileyPeriodicals, Inc. on behalf of the Orthopaedic Research Society. J Orthop Res 9999:1-11, 2017. © 2017 The Authors. Journal of Orthopaedic Research Published by WileyPeriodicals, Inc. on behalf of the Orthopaedic Research Society.
Verma, Diksha; Taneja, Sonali; Kumari, Manju
2018-01-01
This study aims to evaluate and compare the efficacy of various irrigation regimens on push-out bond strength of AH Plus/gutta-percha, Real Seal/Resilon, and MetaSeal/gutta-percha at three different root levels. Single-rooted mandibular premolars ( n = 120) were prepared and divided into four groups ( n = 30) based on irrigation regimen used: I: 5.25% sodium hypochlorite (NaOCl)-17% ethylenediaminetetraacetic acid (EDTA); II: 5.25% NaOCl-2.25% Peracetic acid (PAA); III: 5.25% NaOCl-18% 1-hydroxyethylidene-1, 1-bisphosphonate (HEBP) (Etidronic Acid); and IV: Distilled Water. Each group was further divided into three subgroups ( n = 10); A: AH Plus/gutta-percha; B: MetaSEAL/gutta-percha; C: RealSeal/Resilon. After obturation, roots were sectioned at 3 levels and push-out tests were performed. One-way ANOVA with post hoc Tukey-honestly significant difference tests were applied to assess the significance among various groups. Among irrigants, 2.25% PAA showed significantly lower values when compared with rest of the irrigants. There was no significant difference found among EDTA and HEBP. The push-out bond strength of AH Plus was significantly higher among all sealers. The bond strength values were significantly decreased in apico-coronal direction. There was superior efficacy of EDTA and HEBP on the bond strength of AH Plus at apical root level when compared with other irrigants and sealers at various root levels.
Jia, Rongfang; Lang, Sarah N.; Schoppe-Sullivan, Sarah J.
2015-01-01
Accurate assessment of psychological self-concept in early childhood relies on the development of psychometrically sound instruments. From a developmental perspective, the current study revised an existing measure of young children's psychological self-concepts, the Child Self-View Questionnaire (CSVQ, Eder, 1990), and examined its psychometric properties using a sample of preschool-aged children assessed at approximately 4 years old with a follow-up at age 5 (N = 111). The item compositions of lower-order dimensions were revised, leading to improved internal consistency. Factor Analysis revealed three latent psychological self-concept factors (i.e., Sociability, Control, and Assurance) from the lower-order dimensions. Measurement invariance by gender was supported for Sociability and Assurance, not for Control. Test-retest reliability was supported by stability of the psychological self-concept measurement model during the preschool years, although some evidence of increasing differentiation was obtained. Validity of children's scores on the three latent psychological self-concept factors was tested by investigating their concurrent associations with teacher-reported behavioral adjustment on the Social Competence and Behavior Evaluation Scale – Short Form (SCBE-SF, LaFreniere & Dumas, 1996). Children who perceived themselves as higher in Sociability at 5 years old displayed less internalizing behavior and more social competence; boys who perceived themselves as higher in Control at age 4 exhibited lower externalizing behavior; children higher in Assurance had greater social competence at age 4, but displayed more externalizing behavior at age 5. Implications relevant to the utility of the revised psychological self-concept measure are discussed. PMID:26098231
Modification, validation and implementation of a protocol for post-thyroidectomy hypocalcaemia.
Stedman, T; Chew, P; Truran, P; Lim, C B; Balasubramanian, S P
2018-02-01
Introduction The management of post-thyroidectomy hypocalcaemia should facilitate early discharge, and reduce risks of hypocalcaemia, readmission and treatment related hypercalcaemia. This paper describes the implementation, evaluation and revision a protocol for the optimal management of this condition. Methods Day 1 parathyroid hormone (PTH) measurements in addition to calcium measurements were commenced following review of the unit's outcomes and literature on post-thyroidectomy hypocalcaemia. Outcomes from a three-year cohort of patients undergoing thyroid surgery helped amend this protocol (revision 1) to reduce biochemical tests, stipulate the need, nature and dose of vitamin D/calcium supplements, and encourage early discharge. This was further validated over seven months to assess compliance, episodes of hyper and/or hypocalcaemia after discharge, readmissions and need for treatment changes. Further revisions were made (revision 2) and implemented. Results The temporary and long-term postoperative hypocalcaemia rates were 29.1% and 3.2% respectively. Repeat calcium measurements on the first day altered management in only 1.4% of cases. The revised protocol was adhered to in 90% of cases. One patient had hypocalcaemia (due to non-compliance) and one had hypercalcaemia. Revision 2 involved reducing the dose of calcium. Conclusions This is a good example of a unit protocol for post-thyroidectomy hypocalcaemia being developed and modified on the basis of the literature and local experience. Day 1 PTH and calcium levels determine the need for treatment and frequency of follow-up visits, facilitate early discharge, reduce risk of over and/or undertreatment, and are good indicators of permanent hypocalcaemia.
Incentivizing Multiple Revisions Improves Student Writing without Increasing Instructor Workload
ERIC Educational Resources Information Center
Stellmack, Mark A.; Sandidge, Rita R.; Sippl, Amy L.; Miller, Danneka J.
2015-01-01
Previous research has shown that when students are required to submit a draft and a revision of their writing, large proportions of students do not improve across drafts. We implemented a writing assignment in which students were permitted to submit up to four optional drafts. To encourage substantive revisions, students were awarded additional…
78 FR 20108 - Privacy Act of 1974; Notice of Revised System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-03
...; Notice of Revised System of Records AGENCY: General Services Administration. ACTION: Notice of a revised Privacy Act system of records. SUMMARY: GSA reviewed its Privacy Act systems to ensure that they are relevant, necessary, accurate, up-to-date, and covered by the appropriate legal or regulatory authority...
Sakka, Laurent; Chomicki, Alexandre; Gabrillargues, Jean; Khalil, Toufic; Chazal, Jean; Avan, Paul
2016-02-01
Ventriculoperitoneal shunting is the first-line treatment for normal pressure hydrocephalus. Noninvasive auditory tests based on recorded otoacoustic emissions were assessed, as currently used for universal neonatal hearing screenings, for the diagnosis of cerebrospinal fluid shunt malfunction. The test was designed based on previous works, which demonstrated that an intracranial pressure change induces a proportional, characteristic, otoacoustic-emission phase shift. Forty-four patients with normal pressure hydrocephalus (23 idiopathic and 21 secondary cases) were included in this prospective observational study. The male:female sex ratio was 1.44, the age range was 21-87 years (mean age 64.3 years), and the range of the follow-up period was 1-3 years (mean 20 months). Patients were implanted with a Sophy SU8 adjustable-pressure valve as the ventriculoperitoneal shunt. The phase shifts of otoacoustic emissions in response to body tilt were measured preoperatively, immediately postoperatively, and at 3-6 months, 7-15 months, 16-24 months, and more than 24 months postoperatively. Three groups were enrolled: Group 1, 19 patients who required no valve opening-pressure adjustment; Group 2, 18 patients who required valve opening-pressure adjustments; and Group 3, 7 patients who required valve replacement. In Group 1, phase shift, which was positive before surgery, became steadily negative after surgery and during the follow-up. In Group 2, phase shift, which was positive before surgery, became negative immediately after surgery and increasingly negative after a decrease in the valve-opening pressure. In Group 3, phase shift was positive in 6 cases and slightly negative in 1 case before revision, but after revision phase shift became significantly negative in all cases. Otoacoustic emissions noninvasively reflect cerebrospinal fluid shunt function and are impacted by valve-opening pressure adjustments. Otoacoustic emissions consistently diagnosed shunt malfunction and predicted the need for surgical revision. The authors' diagnostic test, which can be repeated without risk or discomfort by an unskilled operator, may address the crucial need of detecting valve dysfunction in patients with poor clinical outcome after shunt surgery.
A Logic of Appropriation: Enacting National Testing (NAPLAN) in Australia
ERIC Educational Resources Information Center
Hardy, Ian
2014-01-01
This paper explores how the strong policy push to improve students' results on national literacy and numeracy tests -- the National Assessment Program, Literacy and Numeracy (NAPLAN) -- in the Australian state of Queensland influenced schooling practices, including teachers' learning. The paper argues the focus upon improved test scores on NAPLAN…
McGonagle, L; Siney, P D; Raut, V V
2015-11-01
After primary total hip replacement, aseptic loosening of the acetabular cup is more common than loosening of the femoral stem. Removal of a well-fixed stem adds to operative time, blood loss, risk of bone loss and fracture. There is limited evidence that isolated cup revision can be a safe option in revision hip arthroplasty. We question the following regarding the unrevised cemented stem after isolated cup revision: 1) Does the unrevised stem require revision after isolated cup revision? 2) When is the stem subsequently revised? 3) Why is the stem subsequently revised? 4) Do unrevised stems exhibit radiographic loosening? We hypothesise that after isolated cup revision most unrevised stems do not need subsequent revision, and that most do not exhibit evidence of radiographic loosening. A retrospective analysis of all patients who underwent revision of the acetabular component only during revision hip arthroplasty between March 1970 and July 2013 was carried out. We assessed survival of the unrevised stem, reasons for subsequent revision, plus radiographic analysis for stem loosening. Two hundred and twenty-seven hips were included [215 patients with an average age at the time of primary surgery was 47 (13-70) years]. The Charnley stem was used in 161 cases; C-stem 65, Howse 1. Average time between primary surgery and cup revision was 15.9 (1.6-33.4) years. Average follow-up for all stems post-isolated cup revision was 6.1 (0.1-30.7) years. Twenty-eight stems (12.3%) were subsequently revised 5.1 (0.1-12.6) years after the isolated cup revision. Reasons for subsequent revision were: aseptic loosening (10); infection (8); dislocation (6); unreconstructable joint post-loose cup removal (2); fracture (2). Radiographic review was possible on 140 cases. Five femoral stems were revised and 2 others showed evidence of possible radiological loosening but were not revised. To our knowledge this is the largest series showing that isolated cup revision in the place of a well-fixed cemented stem is safe and is associated with ongoing good long-term survival of the stem. Level IV, retrospective case series. Copyright © 2015. Published by Elsevier Masson SAS.
Outcomes of Revision Hip Arthroscopy: 2-Year Clinical Follow-up.
Gupta, Asheesh; Redmond, John M; Stake, Christine E; Dunne, Kevin F; Hammarstedt, Jon E; Domb, Benjamin G
2016-05-01
To evaluate clinical outcomes, pain, and patient satisfaction following revision hip arthroscopy with a minimum 2-year follow-up. From April 2008 to October 2011, data were prospectively collected on all patients undergoing revision hip arthroscopy. All patients were assessed pre- and postoperatively with 4 patient-reported outcome (PRO) measures: the modified Harris hip score (mHHS), nonarthritic hip score (NAHS), hip outcome score-activities of daily living (HOS-ADL), and hip outcome score-sport-specific subscales (HOS-SSS). Pain was estimated on the visual analog scale (VAS). Patient satisfaction was measured on a scale from 0 to 10. The number of patients who underwent subsequent revision arthroscopy or total hip arthroplasty during the study period is also reported. Eighty-seven patients underwent revision hip arthroscopy during the study period. Seventy (80.5%) patients were included in our study. Average follow-up time was 28 months (range, 20 to 47.4 months). In terms of residual femoroacetabular impingement morphology, 45.7% of patients had preoperative alpha angles ≥ 55°, and 7.14% of patients had a lateral center-edge angle ≥ 40°. The score improvement from preoperative to 2-year follow-up was 57.84 to 73.65 for mHHS, 62.79 to 83.04 for HOS-ADL, 37.33 to 54.93 for HOS-SSS, and 55.65 to 70.79 for NAHS. VAS decreased from 6.72 to 4.08. All scores demonstrated statistically significant improvement (P < .001). Overall patient satisfaction was 7.67. Our success rate was 74.58%. Ten (14.29%) patients underwent total hip arthroplasty during the study period. Our hip survivorship was 85.7%. Five (7.14%) patients underwent secondary revision hip arthroscopy during the study period. We found an overall minor complication rate of 10%. Revision hip arthroscopy for all procedures performed on aggregate has improved clinical outcomes for all PROs, high survivorship, and high patient satisfaction scores at short-term follow-up. Patients should be counseled regarding the potential progression of degenerative change leading to arthroplasty and the potential for revision surgery. Level IV retrospective case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
DOT National Transportation Integrated Search
2015-08-01
The seismic cone penetration test with pore pressure measurement (SCPTu) is a geotechnical investigation technique which : involves pushing a sensitized cone into the subsurface at a constant rate while continuously measuring tip resistance, sleeve :...
Evaluation of cone penetration testing (CPT) for use with transportation projects.
DOT National Transportation Integrated Search
2011-04-01
Cone Penetration Testing (CPT) has many advantages as a means for subsurface investigation. CPT consists of pushing a steel : cone into the ground and recording the penetration resistance using sensors. Pore pressure, shear wave velocity and other : ...
Yang, Seung-Cheol; Qian, Xiaoping
2013-09-17
A systematic approach to manipulating flexible carbon nanotubes (CNTs) has been developed on the basis of atomic force microscope (AFM) based pushing. Pushing CNTs enables efficient transport and precise location of individual CNTs. A key issue for pushing CNTs is preventing defective distortion in repetitive bending and unbending deformation. The approach presented here controls lateral movement of an AFM tip to bend CNTs without permanent distortion. The approach investigates possible defects caused by tensile strain of the outer tube under uniform bending and radial distortion by kinking. Using the continuum beam model and experimental bending tests, dependency of maximum bending strain on the length of bent CNTs and radial distortion on bending angles at a bent point have been demonstrated. Individual CNTs are manipulated by limiting the length of bent CNTs and the bending angle. In our approach, multiwalled CNTs with 5-15 nm diameter subjected to bending deformation produce no outer tube breakage under uniform bending and reversible radial deformation with bending angles less than 110°. The lateral tip movement is determined by a simple geometric model that relies on the shape of multiwalled CNTs. The model effectively controls deforming CNT length and bending angle for given CNT shape. Experimental results demonstrate successful manipulation of randomly dispersed CNTs without visual defects. This approach to pushing can be extended to develop a wide range of CNT based nanodevice applications.
Kim, Gye-Yeop; Kin, Se-Hun
2013-12-01
[Purpose] The purpose of this study was to examine the effect of lumbar stability exercises on chronic low back pain by using sling exercise and push-ups. [Subjects] Thirty adult subjects with chronic back pain participated, with 10 adults being assigned to each of 3 exercise groups: general physical therapy (PT), lumbar stability using sling exercises (Sling Ex), and sling exercise plus push-ups (Sling Ex+PU). Each group trained for 30 minutes 3 times a week for 6 weeks. The Oswestry Disability Index (ODI), surface electromyographic (sEMG) activity of the lumbar muscles, and cross-sectional area of the multifidus muscle on computed tomography (CT) were evaluated before and at 2, 4, and 6 weeks of therapy. [Results] A significant decrease in ODI was seen in all therapy groups, and this change was greater in the Sling Ex and Sling Ex+PU groups than in the PT group. No changes in sEMG activity were noted in the PT group, whereas significant increases in the sEMG activities of all lumbar muscles were found in the other 2 groups. The increases in the sEMG activities of the rectus abdominis and internal and external oblique muscles of the abdomen were greater in the Sling Ex+PU group than in the other 2 groups. [Conclusion] These findings demonstrate that Sling Ex+PU, similar to normal lumbar stabilization exercise, is effective in activating and improving the function of the lumbar muscles. These results suggest that Sling Ex+PU has a positive impact on stabilization of the lumbar region.
Development and evaluation of a self-regulating alternating pressure air cushion.
Nakagami, Gojiro; Sanada, Hiromi; Sugama, Junko
2015-03-01
To investigate the effect of alternating air cells of a newly developed dynamic cushion on interface pressure and tissue oxygenation levels. This cross-over experimental study included 19 healthy volunteers. The dynamic cushion used has an automatic self-regulating alternating pressure air-cell system with 35 small and four large air cells for maintaining posture while seated. This cushion also has 17 bottoming-out detectors that automatically inflate the air cells to release a high interface pressure. To assess the effect of this alternating system, participants sat on the new cushion with an alternating system or static system for 30 min and then performed push-ups. The interface pressure was monitored by pressure-sensitive and conductive ink film sensors and tissue oxygenation levels were monitored by near-infrared spectroscopy. A reactive hyperaemia indicator was calculated using tissue oxygenation levels as an outcome measure. The peak interface pressure was not significantly different between the groups. The reactive hyperaemia indicator was significantly higher in the static group than in the alternating group. An alternating system has beneficial effects on blood oxygenation levels without increasing interface pressure. Therefore, our new cushion is promising for preventing pressure ulcers with patients with limited ability to perform push-ups. Implications for Rehabilitation A dynamic cushion was developed, which consists of a uniquely-designed air-cell layout, detectors for bottoming out, and an alternating system with multiple air-cell lines. The alternating system did not increase interface pressure and it significantly reduced reactive hyperaemia after 30 min of sitting in healthy volunteers. This cushion is a new option for individuals who require stable posture but have limitations in performing scheduled push-ups for prevention of pressure ulcers.
Dinc, Engin; Kilinc, Bekir Eray; Bulat, Muge; Erten, Yunus Turgay; Bayraktar, Bülent
2017-10-01
To increase movement capacity and to reduce injury risk in young soccer players by implementing a special functional exercise program based on functional movement screen (FMS) and correctives. 67 young male athletes 14-19 years of age from a Super League Football Club Academy participated in the study. Functional movement patterns were evaluated with FMS assessment protocol. Deep squat, hurdle step, inline lunge, shoulder mobility, active straight leg raise, trunk stability push-up, and rotatory stability were examined in FMS. Considering the FMS scores the number of intervention and control groups were defined as 24 and 43, respectively. Intervention program was composed of 1 hr twice a week sessions in total of 12 weeks with 4 weeks of mobility, 4 weeks of stability, and 4 weeks of integration exercises. At the end of 12-week intervention and control groups were re-evaluated with FMS protocol. Contact and noncontact sports injuries recorded during one season. In intervention group there was statistically significant difference in increase in total FMS scores ( P <0.01), deep squat ( P ≤0.001), hurdle step ( P <0.05), inline lunge ( P <0.01), and trunk stability push-up ( P <0.01). In control group total FMS, deep squat, and trunk stability push-up scores increased with a statistical difference ( P <0.01, P <0.05, P ≤0.01, respectively). The incidence of noncontact injury in control group was higher than intervention group ( P <0.05). Periodic movement screening and proper corrections with functional training is valuable in order to create better movement capacity to build better physical performance and more effective injury prevention.
78 FR 39190 - Revisions to Fitness for Duty Programs' Drug Testing Requirements
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-01
...-0225] RIN 3150-AI67 Revisions to Fitness for Duty Programs' Drug Testing Requirements AGENCY: Nuclear... regarding drug testing requirements in NRC licensees' fitness for duty programs. The regulatory basis...
Peabody Picture Vocabulary Test-Revised (PPVT-R).
ERIC Educational Resources Information Center
Vance, H. Robert; Stone, J. E.
1990-01-01
The Peabody Picture Vocabulary Test-Revised assesses standard American English receptive vocabulary in individuals, both handicapped and nonhandicapped, ages 2 to 40. This paper describes the test's administration, summation of data, standardization, reliability, and validity. (JDD)
2013-01-01
Background Chronic work-related stress is an independent risk factor for cardiometabolic diseases and associated mortality, particularly when compounded by a sedentary work environment. The purpose of this study was to determine if an office worksite-based hatha yoga program could improve physiological stress, evaluated via heart rate variability (HRV), and associated health-related outcomes in a cohort of office workers. Methods Thirty-seven adults employed in university-based office positions were randomized upon the completion of baseline testing to an experimental or control group. The experimental group completed a 10-week yoga program prescribed three sessions per week during lunch hour (50 min per session). An experienced instructor led the sessions, which emphasized asanas (postures) and vinyasa (exercises). The primary outcome was the high frequency (HF) power component of HRV. Secondary outcomes included additional HRV parameters, musculoskeletal fitness (i.e. push-up, side-bridge, and sit & reach tests) and psychological indices (i.e. state and trait anxiety, quality of life and job satisfaction). Results All measures of HRV failed to change in the experimental group versus the control group, except that the experimental group significantly increased LF:HF (p = 0.04) and reduced pNN50 (p = 0.04) versus control, contrary to our hypotheses. Flexibility, evaluated via sit & reach test increased in the experimental group versus the control group (p < 0.001). No other adaptations were noted. Post hoc analysis comparing participants who completed ≥70% of yoga sessions (n = 11) to control (n = 19) yielded the same findings, except that the high adherers also reduced state anxiety (p = 0.02) and RMSSD (p = 0.05), and tended to improve the push-up test (p = 0.07) versus control. Conclusions A 10-week hatha yoga intervention delivered at the office worksite during lunch hour did not improve HF power or other HRV parameters. However, improvements in flexibility, state anxiety and musculoskeletal fitness were noted with high adherence. Future investigations should incorporate strategies to promote adherence, involve more frequent and longer durations of yoga training, and enrol cohorts who suffer from higher levels of work-related stress. Trial registration ACTRN12611000536965 PMID:23574691
Balsalobre-Fernández, Carlos; Kuzdub, Matt; Poveda-Ortiz, Pedro; Campo-Vecino, Juan Del
2016-07-01
Balsalobre-Fernández, C, Kuzdub, M, Poveda-Ortiz, P, and Campo-Vecino, Jd. Validity and reliability of the PUSH wearable device to measure movement velocity during the back squat exercise. J Strength Cond Res 30(7): 1968-1974, 2016-The purpose of this study was to analyze the validity and reliability of a wearable device to measure movement velocity during the back squat exercise. To do this, 10 recreationally active healthy men (age = 23.4 ± 5.2 years; back squat 1 repetition maximum [1RM] = 83 ± 8.2 kg) performed 3 repetitions of the back squat exercise with 5 different loads ranging from 25 to 85% 1RM on a Smith Machine. Movement velocity for each of the total 150 repetitions was simultaneously recorded using the T-Force linear transducer (LT) and the PUSH wearable band. Results showed a high correlation between the LT and the wearable device mean (r = 0.85; standard error of estimate [SEE] = 0.08 m·s) and peak velocity (r = 0.91, SEE = 0.1 m·s). Moreover, there was a very high agreement between these 2 devices for the measurement of mean (intraclass correlation coefficient [ICC] = 0.907) and peak velocity (ICC = 0.944), although a systematic bias between devices was observed (PUSH peak velocity being -0.07 ± 0.1 m·s lower, p ≤ 0.05). When measuring the 3 repetitions with each load, both devices displayed almost equal reliability (Test-retest reliability: LT [r = 0.98], PUSH [r = 0.956]; ICC: LT [ICC = 0.989], PUSH [ICC = 0.981]; coefficient of variation [CV]: LT [CV = 4.2%], PUSH [CV = 5.0%]). Finally, individual load-velocity relationships measured with both the LT (R = 0.96) and the PUSH wearable device (R = 0.94) showed similar, very high coefficients of determination. In conclusion, these results support the use of an affordable wearable device to track velocity during back squat training. Wearable devices, such as the one in this study, could have valuable practical applications for strength and conditioning coaches.
Ratamess, Nicholas A; Beller, Noah A; Gonzalez, Adam M; Spatz, Gregory E; Hoffman, Jay R; Ross, Ryan E; Faigenbaum, Avery D; Kang, Jie
2016-03-01
The transfer of training effects of multiple-joint isokinetic resistance training to dynamic exercise performance remain poorly understood. Thus, the purpose of the present study was to investigate the magnitude of isokinetic and dynamic one repetition-maximum (1RM) strength and local muscular endurance increases after 6 weeks of multiple-joint isokinetic resistance training. Seventeen women were randomly assigned to either an isokinetic resistance training group (IRT) or a non-exercising control group (CTL). The IRT group underwent 6 weeks of training (2 days per week) consisting of 5 sets of 6-10 repetitions at 75-85% of subjects' peak strength for the isokinetic chest press and seated row exercises at an average linear velocity of 0.15 m s(-1) [3-sec concentric (CON) and 3-sec eccentric (ECC) phases]. Peak CON and ECC force during the chest press and row, 1RM bench press and bent-over row, and maximum number of modified push-ups were assessed pre and post training. A 2 x 2 analysis of variance with repeated measures and Tukey's post hoc tests were used for data analysis. The results showed that 1RM bench press (from 38.6 ± 6.7 to 43.0 ± 5.9 kg), 1RM bent-over row (from 40.4 ± 7.7 to 45.5 ± 7.5 kg), and the maximal number of modified push-ups (from 39.5 ± 13.6 to 55.3 ± 13.1 repetitions) increased significantly only in the IRT group. Peak isokinetic CON and ECC force in the chest press and row significantly increased in the IRT group. No differences were shown in the CTL group for any measure. These data indicate 6 weeks of multiple-joint isokinetic resistance training increases dynamic muscle strength and local muscular endurance performance in addition to specific isokinetic strength gains in women. Key pointsMultiple-joint isokinetic resistance training increases dynamic maximal muscular strength, local muscular endurance, and maximal isokinetic strength in women.Multiple-joint isokinetic resistance training increased 1RM strength in the bench press (by 10.2%), bent-over barbell row (by 11.2%), and maximal modified push-up performance (by 28.6%) indicating a carryover of training effects to dynamic exercise performance.The carryover effects may be attractive to strength training and conditioning professionals seeking to include alternative modalities such as multiple-joint isokinetic dynamometers to resistance training programs.
Ratamess, Nicholas A.; Beller, Noah A.; Gonzalez, Adam M.; Spatz, Gregory E.; Hoffman, Jay R.; Ross, Ryan E.; Faigenbaum, Avery D.; Kang, Jie
2016-01-01
The transfer of training effects of multiple-joint isokinetic resistance training to dynamic exercise performance remain poorly understood. Thus, the purpose of the present study was to investigate the magnitude of isokinetic and dynamic one repetition-maximum (1RM) strength and local muscular endurance increases after 6 weeks of multiple-joint isokinetic resistance training. Seventeen women were randomly assigned to either an isokinetic resistance training group (IRT) or a non-exercising control group (CTL). The IRT group underwent 6 weeks of training (2 days per week) consisting of 5 sets of 6-10 repetitions at 75-85% of subjects’ peak strength for the isokinetic chest press and seated row exercises at an average linear velocity of 0.15 m s-1 [3-sec concentric (CON) and 3-sec eccentric (ECC) phases]. Peak CON and ECC force during the chest press and row, 1RM bench press and bent-over row, and maximum number of modified push-ups were assessed pre and post training. A 2 x 2 analysis of variance with repeated measures and Tukey’s post hoc tests were used for data analysis. The results showed that 1RM bench press (from 38.6 ± 6.7 to 43.0 ± 5.9 kg), 1RM bent-over row (from 40.4 ± 7.7 to 45.5 ± 7.5 kg), and the maximal number of modified push-ups (from 39.5 ± 13.6 to 55.3 ± 13.1 repetitions) increased significantly only in the IRT group. Peak isokinetic CON and ECC force in the chest press and row significantly increased in the IRT group. No differences were shown in the CTL group for any measure. These data indicate 6 weeks of multiple-joint isokinetic resistance training increases dynamic muscle strength and local muscular endurance performance in addition to specific isokinetic strength gains in women. Key points Multiple-joint isokinetic resistance training increases dynamic maximal muscular strength, local muscular endurance, and maximal isokinetic strength in women. Multiple-joint isokinetic resistance training increased 1RM strength in the bench press (by 10.2%), bent-over barbell row (by 11.2%), and maximal modified push-up performance (by 28.6%) indicating a carryover of training effects to dynamic exercise performance. The carryover effects may be attractive to strength training and conditioning professionals seeking to include alternative modalities such as multiple-joint isokinetic dynamometers to resistance training programs. PMID:26957924
Flight and Wind-tunnel Tests of an XBM-1 Dive Bomber
NASA Technical Reports Server (NTRS)
Donely, Philip; Pearson, Henry A
1938-01-01
Results are given of pressure-distribution measurements made in flight over the right wing cellule and the right half of the horizontal tail surfaces of a dive-bombing biplane. Simultaneous measurements were also taken of the air speed, control-surface positions, control forces, and normal accelerations during various abrupt maneuvers in vertical plane. These maneuvers consisted of push-downs and pull-ups from level flight, dives and dive pull-ups from inverted flight. Besides the pressure measurements, flight tests were made to obtain (1) wing-fabric deflections during dives and (2) variation of the minimum drag coefficient with Reynolds Number. Supplementary tests were also done in the full-scale wind tunnel to obtain the characteristics of the airplane under various propeller conditions and with various tail settings. The results indicate that: (1) by increasing the fabric deflection between pressure ribs, the span load distribution was considerably modified near the center and the wing moment relations were changed; and (2) the minimum drag was less for the idling propeller than for the propeller locked in a vertical position. The value of C(sub D sub min) was equal to K(Reynolds Number)(exp -0.03) for a range from 2,800,000 to 13,100,000.
Eather, Narelle; Morgan, Philip J; Lubans, David R
2013-01-01
To evaluate the impact of a multi-component school-based physical activity intervention (Fit-4-Fun) on health-related fitness and objectively measured physical activity in primary school children. Four Hunter primary schools were recruited in April, 2011 and randomized by school into treatment or control conditions. Participants included 213 children (mean age = 10.72 years ± 0.6; 52.2% female) with the treatment group (n = 118) completing the 8-week Fit-4-Fun Program. Participants were assessed at baseline and 6-month follow-up, with a 91% retention rate. Cardio-respiratory fitness (CRF) (20 m shuttle run) was the primary outcome, and secondary outcomes included body composition (BMI, BMI(Z)), muscular fitness (7-stage sit-up test, push-up test, basketball throw test, Standing Jump), flexibility (sit and reach) and physical activity (7 days pedometry). After 6-months, significant treatment effects were found for CRF (adjusted mean difference, 1.14 levels, p < 0.001), body composition (BMI mean, -0.96 kg/m(2), p < 0.001 and BMI z-score mean -0.47 z-scores, p < 0.001), flexibility (sit and reach mean, 1.52 cm, p = 0.0013), muscular fitness (sit-ups) (mean 0.62 stages, p = 0.003) and physical activity (mean, 3253 steps/day, p < 0.001). There were no group by time effects for the other muscular fitness measures. A primary school-based intervention focusing on fitness education significantly improved health-related fitness and physical activity levels in children. Copyright © 2012 Elsevier Inc. All rights reserved.
Observations of Hydrated Minerals on Asteroids: Pushing Back the Frontiers
NASA Technical Reports Server (NTRS)
2005-01-01
The three accomplishments during this grant include: 1) Travel to 2004 Division of Planetary Science (of American Astronomical Society) Conference in Louisville, KY and presentation of Rotationally resolved spectroscopy of Vesta in the 1-4 micron region, abstract 28.07. 2) Remote observations using the IRTF on 20-21 June 2004 and 28-3 1 August 2004, and reduction of data as described in the grant proposal and descoping document. These observations confirm the presence of two different band shapes among C-class asteroid spectra in the 3-micron region. This allowed a revision of the known distribution of Ceres- and Pallas-type objects. 3) Remote observations using the IRTF on 7-10 August 2004. These observations of Vesta were presented, and the manuscript will be submitted to Icarus in June.
Wright, Rick W.; Huston, Laura J.; Haas, Amanda K.; Spindler, Kurt P.; Nwosu, Sam K.; Allen, Christina R.; Anderson, Allen F.; Cooper, Daniel E.; DeBerardino, Thomas M.; Dunn, Warren R.; Lantz, Brett (Brick) A.; Stuart, Michael J.; Garofoli, Elizabeth A.; Albright, John P.; Amendola, Annunziato (Ned); Andrish, Jack T.; Annunziata, Christopher C.; Arciero, Robert A.; Bach, Bernard R.; Baker, Champ L.; Bartolozzi, Arthur R.; Baumgarten, Keith M.; Bechler, Jeffery R.; Berg, Jeffrey H.; Bernas, Geoffrey A.; Brockmeier, Stephen F.; Brophy, Robert H.; Bush-Joseph, Charles A.; Butler, J. Brad; Campbell, John D.; Carey, James L.; Carpenter, James E.; Cole, Brian J.; Cooper, Jonathan M.; Cox, Charles L.; Creighton, R. Alexander; Dahm, Diane L.; David, Tal S.; Flanigan, David C.; Frederick, Robert W.; Ganley, Theodore J.; Gatt, Charles J.; Gecha, Steven R.; Giffin, James Robert; Hame, Sharon L.; Hannafin, Jo A.; Harner, Christopher D.; Harris, Norman Lindsay; Hechtman, Keith S.; Hershman, Elliott B.; Hoellrich, Rudolf G.; Hosea, Timothy M.; Johnson, David C.; Johnson, Timothy S.; Jones, Morgan H.; Kaeding, Christopher C.; Kamath, Ganesh V.; Klootwyk, Thomas E.; Levy, Bruce A.; Ma, C. Benjamin; Maiers, G. Peter; Marx, Robert G.; Matava, Matthew J.; Mathien, Gregory M.; McAllister, David R.; McCarty, Eric C.; McCormack, Robert G.; Miller, Bruce S.; Nissen, Carl W.; O'Neill, Daniel F.; Owens, Brett D.; Parker, Richard D.; Purnell, Mark L.; Ramappa, Arun J.; Rauh, Michael A.; Rettig, Arthur C.; Sekiya, Jon K.; Shea, Kevin G.; Sherman, Orrin H.; Slauterbeck, James R.; Smith, Matthew V.; Spang, Jeffrey T.; Svoboda, Steven J.; Taft, Timothy N.; Tenuta, Joachim J.; Tingstad, Edwin M.; Vidal, Armando F.; Viskontas, Darius G.; White, Richard A.; Williams, James S.; Wolcott, Michelle L.; Wolf, Brian R.; York, James J.
2015-01-01
Background Most surgeons believe that graft choice for ACL reconstruction is an important factor related to outcome. Although graft choice may be limited in the revision setting based on previously used grafts, it is still felt to be important. Hypothesis The purpose of this study was to determine if revision ACL graft choice predicts outcomes related to sports function, activity level, OA symptoms, graft re-rupture, and reoperation at two years following revision reconstruction. We hypothesized that autograft use would result in increased sports function, increased activity level, and decreased OA symptoms (as measured by validated patient reported outcome instruments). Additionally, we hypothesized that autograft use would result in decreased graft failure and reoperation rate 2 years following revision ACL reconstruction. Study Design Prospective cohort study; Level of evidence, 2. Methods Revision ACL reconstruction patients were identified and prospectively enrolled by 83 surgeons over 52 sites. Data collected included baseline demographics, surgical technique and pathology, and a series of validated patient reported outcome instruments (IKDC, KOOS, WOMAC, and Marx activity rating score). Patients were followed up at 2 years, and asked to complete the identical set of outcome instruments. Incidence of additional surgery and reoperation due to graft failure were also recorded. Multivariate regression models were used to determine the predictors (risk factors) of IKDC, KOOS, WOMAC, Marx scores, graft re-rupture, and reoperation rate at 2 years following revision surgery. Results 1205 patients were successfully enrolled with 697 (58%) males. Median age was 26. In 88% this was their first revision. 341 (28%) were undergoing revision by the surgeon that had performed the previous reconstruction. 583 (48%) underwent revision reconstruction utilizing an autograft, 590 (49%) allograft, and 32 (3%) both autograft and allograft. Median time since their last ACL reconstruction was 3.4 years. Questionnaire follow-up was obtained on 989 subjects (82%), while phone follow-up was obtained on 1112 subjects (92%). The IKDC, KOOS, and WOMAC scores (with the exception of the WOMAC stiffness subscale) all significantly improved at the two year follow-up time point (p<0.001). In contrast, the two year MARX activity scale demonstrated a significant decrease from the initial score at enrollment (p<0.001). Graft choice proved to be a significant predictor of 2 year IKDC scores (p=0.017). Specifically, the use of an autograft for revision reconstruction predicted improved score on the IKDC [p=0.045; Odds Ratio (OR) = 1.31; 95% confidence intervals (CI) = 1.01, 1.70]. The use of an autograft predicted an improved on the KOOS subscale Sports and Recreation (p=0.037; OR=1.33; 95% CI=1.02, 1.73). Use of an autograft also predicted improved scores on the KOOS subscale Quality of Life (QOL) (p=0.031; OR=1.33; 95% CI=1.03, 1.73). For the KOOS Symptoms and ADL subscales, graft choice did not predict outcome score. Graft choice also proved to be a significant predictor of 2 year Marx activity level scores (p=0.012). Graft re-rupture was reported in 37/1112 (3.3%) of patients by their two year follow-up: 24 allografts, 12 autografts, and 1 allograft + autograft. Use of an autograft for revision resulted in patients 2.78 times less likely to sustain a subsequent graft rupture than if an allograft was utilized (p=0.047; 95% CI=1.01, 7.69). Conclusions Improved sports function and patient reported outcome measures are obtained when an autograft is utilized. Additionally, use of an autograft shows a decreased risk in graft re-rupture at two years follow-up. No differences were noted in rerupture or patient reported outcomes between soft tissue and bone-patellar tendon-bone grafts. Surgeon education regarding the findings in this study can result in potentially improved revision ACL reconstruction results for our patients. PMID:25274353
A comparison of the Monti and spiral Monti procedures: A long-term analysis.
Whittam, B M; Szymanski, K M; Flack, C; Misseri, R; Kaefer, M; Rink, R C; Cain, M P
2015-06-01
The Monti ileovesicostomy provides an excellent substitution for an appendicovesicostomy when the appendix is unavailable or suitable for use. The spiral Monti is a useful modification to the traditional Monti as it allows creation of a longer channel when needed. In 2007, the short-term outcomes were reported; they compared traditional and spiral Monti in 188 patients with an average follow-up of 43 months. In the present population, a total of 25 subfasical revisions were performed in 21 patients: nine (8.3%) subfascial revisions in the traditional Monti (TM) patients and 12 (15.2%) subfascial revisions in the spiral Monti (SM) patients. The study found an increased risk of subfascial revisions of either TM or SM when the stoma was located at the umbilicus versus right lower quadrant (16.8% vs 6.3%, P < 0.05). On subgroup analysis, this increased subfascial revision rate appeared to be driven by SM channels to the umbilicus rather than other stomal locations, but this trend was not statistically significant. It was hypothesized that with longer follow-up, the spiral Monti would require more subfascial revisions due to progressive lengthening of the channel. A retrospective chart review was performed for all patients undergoing a traditional Monti (TM) or spiral Monti (SM) procedure at the present institution (1997-2013). Patient demographics, bowel segment used, stomal location, channel or stomal revisions, number of anesthetic endoscopic procedures performed, and indications for revision were reviewed. Kaplan-Meier analysis and Cox proportional hazards modeling was used for analysis. Of the 296 patients identified, 146 had Monti procedures and 150 had spiral Monti procedures (median follow-up 7.7 years). Median age at surgery was 10.6 years. Myelomeningocele was the most common underlying cause of neuropathic bladder, totaling 169 (57.1%) patients. Stomas were located at the umbilicus (106, 35.8%), right lower quadrant (183, 61.8%) and left lower quadrant (seven, 2.4%). Median follow-up for the entire cohort was 7.7 years (range: 1 month-15.7 years). Stomal stenosis rate was 7.4%, and 96.6% of the channels were continent. A total of 87 revisions were performed in 74 patients (25.0%). Of these, 55 were subfascial revisions in 49 patients (16.6%). The umbilical spiral Monti on univariate and multivariate analysis was found to be over twice as likely to undergo subfascial revision. The majority of patients with a Monti channel had durable results and did not require further channel surgery with long-term follow-up. Spiral Monti channels to the umbilicus were more than twice as likely to undergo subfascial revision compared to all other Monti channels. Overall, one in three umbilical SM channels required a subfascial revision at 10 years after the initial surgery, compared to one in six of all other Monti channels. The study was limited by being a retrospective, single-center series; however, it does represent the largest series of pure SM and TM patients. It focused only on surgical interventions, thus was likely to underestimate the overall risk of complications, as some complications were managed conservatively. As in all studies, some patients were lost to follow-up and inevitably some of these may have had complications. Correction for this was attempted through survival analysis. The present study reported durable and reliable long-term results with Monti and spiral Monti procedures based on a large patient cohort. Spiral Monti to the umbilicus was more than twice as likely to require a subfascial revision. Copyright © 2015 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.
A Long-Term BCI Study With ECoG Recordings in Freely Moving Rats.
Costecalde, Thomas; Aksenova, Tetiana; Torres-Martinez, Napoleon; Eliseyev, Andriy; Mestais, Corinne; Moro, Cecile; Benabid, Alim Louis
2018-02-01
Brain Computer Interface (BCI) studies are performed in an increasing number of applications. Questions are raised about electrodes, data processing and effectors. Experiments are needed to solve these issues. To develop a simple BCI set-up to easier studies for improving the mathematical tools to process the ECoG to control an effector. We designed a simple BCI using transcranial electrodes (17 screws, three mechanically linked to create a common reference, 14 used as recording electrodes) to record Electro-Cortico-Graphic (ECoG) neuronal activities in rodents. The data processing is based on an online self-paced non-supervised (asynchronous) BCI paradigm. N-way partial least squares algorithm together with Continuous Wavelet Transformation of ECoG recordings detect signatures related to motor activities. Signature detection in freely moving rats may activate external effectors during a behavioral task, which involved pushing a lever to obtain a reward. After routine training, we showed that peak brain activity preceding a lever push (LP) to obtain food reward was located mostly in the cerebellar cortex with a higher correlation coefficient, suggesting a strong postural component and also in the occipital cerebral cortex. Analysis of brain activities provided a stable signature in the high gamma band (∼180Hz) occurring within 1500 msec before the lever push approximately around -400 msec to -500 msec. Detection of the signature from a single cerebellar cortical electrode triggers the effector with high efficiency (68% Offline and 30% Online) and rare false positives per minute in sessions about 30 minutes and up to one hour (∼2 online and offline). In summary, our results are original as compared to the rest of the literature, which involves rarely rodents, a simple BCI set-up has been developed in rats, the data show for the first time long-term, up to one year, unsupervised online control of an effector. © 2017 International Neuromodulation Society.
Sadhu, Anita; Calfee, Ryan P.; Guthrie, Andre; Wall, Lindley B.
2016-01-01
Purpose To test the null hypothesis that there is no difference in patient-reported and objective outcomes of revision ligament reconstruction and tendon interposition (LRTI) compared to primary LRTI. Methods This case-control investigation enrolled 10 patients who had undergone revision LRTI at a tertiary care center. All patients had previously undergone primary trapeziectomy with LRTI. Patients with a minimum of two years of follow-up were eligible. All patients completed an in-office study evaluation. Controls (treated only with primary LRTI) were matched from our practice to reach a 1:2 case to control ratio. Outcome measures included Michigan Hand Questionnaire (primary outcome), Quick Disability of the Arm, Hand, and Shoulder (QuickDASH) Questionnaire, VAS for pain and improvement, and physical examination. Statistical analyses were conducted to compare the patient groups. Results Revision LRTI patients reported significantly worse outcomes on all measured standardized questionnaires compared with primary patients. The Michigan Hand Questionnaire indicated worse overall outcomes (54 versus 79) as well as worse pain, appearance, and ability to complete activities of daily living. Revision LRTI patients also reported more impairment (QuickDASH 47 versus 23), greater pain (VAS pain 6.3 versus 1), and less improvement after surgery (VAS improvement 2.7 versus 7.9). There was also a significantly higher rate of patient-reported depression in the revision LRTI group (50% versus 10% of primary LRTI patients). We did not find a significant difference in objective outcomes of pinch strength, grip strength, and thumb palmar abduction between the two groups. Conclusion Following revision LRTI patient-reported outcomes indicate worse perceived function and greater pain than expected following primary LRTI despite similar motion and strength. Revision surgery can be offered in the setting of persistent or recurrent symptoms, but patients should be counseled that improvement of symptoms is unpredictable. PMID:27751779
Thirteen-year outcomes in the Anatomique Benoist Girard II hip prosthesis.
Catanach, Michael J M; Sorial, Rami M; Eslick, Guy D
2015-04-01
The Stryker Anatomique Benoist Girard (ABG) hip implant system was a commonly used cementless prosthesis in the early 2000s, which fell from favour after several studies emerged implicating the prosthesis in high rates of revision. This retrospective, single-surgeon clinical study examines the fracture rate, revision rate and reasons for revision in 500 consecutive ABG II primary total conventional hip replacements. Follow-up was conducted by audit of patient notes, patient mailout survey, patient phone contact and audit of the Australian National Joint Replacement Registry (NJRR) database to find instances of fracture and revision. End points were periprosthetic fracture and revision for any reason. Follow-up was 1.2-13.8 years with a mean of 6.58 years. Of the 500 hips, 17 (3.4%) had undergone a revision. Of these, 13 were due to periprosthetic fracture. Four further fractures occurred that were not revised. Eight of these periprosthetic fractures occurred within 1 year post-operatively. There were four revisions for recurrent dislocations. Kaplan-Meier survival curve demonstrates a 93.7% survivorship at 6.58 years for revision for any reason. Multivariate analysis showed the only statistically significant factor for increased risk of revision was smaller stem size. Our results were consistent with the literature in that the ABG II system has good medium-term results but is prone to periprosthetic fractures, especially in the early post-operative period. When used as a primary total hip arthroplasty, the ABG II system has an 8-year revision rate of 5.6% compared with the 4.9% of all primary total hip arthroplasties. © 2014 Royal Australasian College of Surgeons.
Progress towards extreme attitude testing with Magnetic Suspension and Balance Systems
NASA Technical Reports Server (NTRS)
Britcher, Colin P.; Parker, David H.
1988-01-01
Progress is reported in a research effort aimed towards demonstration of the feasibility of suspension and aerodynamic testing of models at high angles of attack in wind tunnel Magnetic Suspension and Balance Systems. Extensive modifications, described in this paper, have been made to the Southampton University suspension system in order to facilitate this work. They include revision of electromagnet configuration, installation of all-new position sensors and expansion of control system programs. An angle of attack range of 0 to 90 deg is expected for axisymmetric models. To date, suspension up to 80 deg angle of attack has been achieved.
Revising Rationality: The Use of "Nudge" Approaches in Neoliberal Education Policy
ERIC Educational Resources Information Center
Bradbury, Alice; McGimpsey, Ian; Santori, Diego
2013-01-01
This article argues that the concept of rationality is undergoing significant revision in UK education policy-making, influenced by developments in several academic fields. This article focuses on the take up of behavioural economics in policy as one aspect of this revision of the concept of rationality, discussing how this has happened and its…
Muon g-2 Ring Moving up Illinois River
DOE Office of Scientific and Technical Information (OSTI.GOV)
none
2013-07-20
This clip shows the "Miss Katie" pushing the muon g-2 ring upstream on the Illinois River, and passing through the Peoria Lock and Dam as it travels toward Lemont, where it will be unloaded onto the special Emmert transporter and driven to Fermilab.
Follow Up: Credit Card Caution
ERIC Educational Resources Information Center
Cahill, Timothy P.
2007-01-01
In "Pushing Plastic," ("The New England Journal of Higher Education", Summer 2007), John Humphrey notes that many college administrators justify their credit card solicitations by suggesting that credit card access will help students learn to manage their own finances. Instead, credit card debt will teach thousands of students…
Ultrasports Are In--In Spite of Injuries.
ERIC Educational Resources Information Center
Murphy, Patrick
1986-01-01
Participation in ultraendurance sports events is up. Ultraendurance athletes are pushing their bodies to limits that haven't been achieved before. Overuse injuries are the most common complaint, but other medical problems occur with frequency. Events are described, as are injuries associated with them. (MT)
Assessment of modified gold surfaced titanium implants on skeletal fixation.
Zainali, Kasra; Danscher, Gorm; Jakobsen, Thomas; Baas, Jorgen; Møller, Per; Bechtold, Joan E; Soballe, Kjeld
2013-01-01
Noncemented implants are the primary choice for younger patients undergoing total hip replacements. However, the major concern in this group of patients regarding revision is the concern from wear particles, periimplant inflammation, and subsequently aseptic implant loosening. Macrophages have been shown to liberate gold ions through the process termed dissolucytosis. Furthermore, gold ions are known to act in an anti-inflammatory manner by inhibiting cellular NF-κB-DNA binding. The present study investigated whether partial coating of titanium implants could augment early osseointegration and increase mechanical fixation. Cylindrical porous coated Ti-6Al-4V implants partially coated with metallic gold were inserted in the proximal region of the humerus in ten canines and control implants without gold were inserted in contralateral humerus. Observation time was 4 weeks. Biomechanical push out tests and stereological histomorphometrical analyses showed no statistically significant differences in the two groups. The unchanged parameters are considered an improvement of the coating properties, as a previous complete gold-coated implant showed inferior mechanical fixation and reduced osseointegration compared to control titanium implants in a similar model. Since sufficient early mechanical fixation is achieved with this new coating, it is reasonable to investigate the implant further in long-term studies. Copyright © 2012 Wiley Periodicals, Inc.
Roukis, Thomas S
2012-01-01
Revision of failed total ankle replacement remains a challenge with limited information available to guide treatment options. I undertook a systematic review of electronic databases and other relevant sources to identify material relating to the incidence of revision after primary implantation of the Agility™ Total Ankle Replacement System. In an effort to procure the highest quality studies available, studies were eligible for inclusion only if they involved patients undergoing primary Agility™ Total Ankle Replacement; had evaluated patients at a mean follow-up of 12 months or longer; included details of the revision performed; and included revision etiologies of aseptic loosening, ballooning osteolysis, cystic changes, malalignment, or instability. A total of 14 studies involving 2312 ankles, with a weighted mean follow-up of 22.8 months, were included. Of the 2312 ankles, 224 (9.7%) underwent revision, of which 182 (81.3%) underwent implant component replacement, 34 (15.2%) underwent arthrodesis, and 8 (3.6%) underwent below-knee amputation. No significant effect from the surgeon's learning curve on the incidence of revision or the type of revision surgery performed was identified. However, excluding the inventor increased the incidence of revision twofold, from 6.6% to 12.2%, and skewed the type of revision away from arthrodesis and toward implant component replacement or below-knee amputation. Regardless, the incidence of revision after primary implantation of the Agility™ Total Ankle Replacement System was less than historically reported and amenable to implant component revision more than 80% of the time. However, methodologically sound cohort studies are needed that include the outcomes after revision surgery, specifically focusing on what implant component replacement techniques are effective in enhancing survivorship of these revised implants and the role of custom-stemmed talar and tibial components have in revision of the Agility™ Total Ankle Replacement System. A direct comparison of the incidence of revision between the various contemporary total ankle replacement systems in common use is also warranted. Copyright © 2012 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.
Results of revision anterior shoulder stabilization surgery in adolescent athletes.
Blackman, Andrew J; Krych, Aaron J; Kuzma, Scott A; Chow, Roxanne M; Camp, Christopher; Dahm, Diane L
2014-11-01
The purpose of this study was to determine failure rates, functional outcomes, and risk factors for failure after revision anterior shoulder stabilization surgery in high-risk adolescent athletes. Adolescent athletes who underwent primary anterior shoulder stabilization were reviewed. Patients undergoing subsequent revision stabilization surgery were identified and analyzed. Failure rates after revision surgery were assessed by Kaplan-Meier analysis. Failure was defined as recurrent instability requiring reoperation. Functional outcomes included the Marx activity score; American Shoulder and Elbow Surgeons score; and University of California, Los Angeles score. The characteristics of patients who required reoperation for recurrent instability after revision surgery were compared with those of patients who required only a single revision to identify potential risk factors for failure. Of 90 patients who underwent primary anterior stabilization surgery, 15 (17%) had failure and underwent revision surgery (mean age, 16.6 years; age range, 14 to 18 years). The mean follow-up period was 5.5 years (range, 2 to 12 years). Of the 15 revision patients, 5 (33%) had recurrent dislocations and required repeat revision stabilization surgery at a mean of 50 months (range, 22 to 102 months) after initial revision. No risk factors for failure were identified. The Kaplan-Meier reoperation-free estimates were 86% (95% confidence interval, 67% to 100%) at 24 months and 78% (95% confidence interval, 56% to 100%) at 48 months after revision surgery. The mean final Marx activity score was 14.8 (range, 5 to 20); American Shoulder and Elbow Surgeons score, 82.1 (range, 33 to 100); and University of California, Los Angeles score, 30.8 (range, 16 to 35). At 5.5 years' follow-up, adolescent athletes had a high failure rate of revision stabilization surgery and modest functional outcomes. We were unable to convincingly identify specific risk factors for failure of revision surgery. Level IV, retrospective therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Comparison of mode of failure between primary and revision total knee arthroplasties.
Liang, H; Bae, J K; Park, C H; Kim, K I; Bae, D K; Song, S J
2018-04-01
Cognizance of common reasons for failure in primary and revision TKA, together with their time course, facilitates prevention. However, there have been few reports specifically comparing modes of failure for primary vs. revision TKA using a single prosthesis. The goal of the study was to compare the survival rates, modes of failure, and time periods associated with each mode of failure, of primary vs. revision TKA. The survival rates, modes of failure, time period for each mode of failure, and risk factors would differ between primary and revision TKA. Data from a consecutive cohort comprising 1606 knees (1174 patients) of primary TKA patients, and 258 knees (224 patients) of revision TKA patients, in all of whom surgery involved a P.F.C ® prosthesis (Depuy, Johnson & Johnson, Warsaw, IN), was retrospectively reviewed. The mean follow-up periods of primary and revision TKAs were 9.2 and 9.8 years, respectively. The average 10- and 15-year survival rates for primary TKA were 96.7% (CI 95%,±0.7%) and 85.4% (CI 95%,±2.0%), and for revision TKA 91.4% (CI 95%,±2.5%) and 80.5% (CI 95%,±4.5%). Common modes of failure included polyethylene wear, loosening, and infection. The most common mode of failure was polyethylene wear in primary TKA, and infection in revision TKA. The mean periods (i.e., latencies) of polyethylene wear and loosening did not differ between primary and revision TKAs, but the mean period of infection was significantly longer for revision TKA (1.2 vs. 4.8 years, P=0.003). Survival rates decreased with time, particularly more than 10 years post-surgery, for both primary and revision TKAs. Continuous efforts are required to prevent and detect the various modes of failure during long-term follow-up. Greater attention is necessary to detect late infection-induced failure following revision TKA. Case-control study, Level III. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Validation of a mobility item bank for older patients in primary care.
Cabrero-García, Julio; Ramos-Pichardo, Juan Diego; Muñoz-Mendoza, Carmen Luz; Cabañero-Martínez, María José; González-Llopis, Lorena; Reig-Ferrer, Abilio
2012-12-05
To develop and validate an item bank to measure mobility in older people in primary care and to analyse differential item functioning (DIF) and differential bundle functioning (DBF) by sex. A pool of 48 mobility items was administered by interview to 593 older people attending primary health care practices. The pool contained four domains based on the International Classification of Functioning: changing and maintaining body position, carrying, lifting and pushing, walking and going up and down stairs. The Late Life Mobility item bank consisted of 35 items, and measured with a reliability of 0.90 or more across the full spectrum of mobility, except at the higher end of better functioning. No evidence was found of non-uniform DIF but uniform DIF was observed, mainly for items in the changing and maintaining body position and carrying, lifting and pushing domains. The walking domain did not display DBF, but the other three domains did, principally the carrying, lifting and pushing items. During the design and validation of an item bank to measure mobility in older people, we found that strength (carrying, lifting and pushing) items formed a secondary dimension that produced DBF. More research is needed to determine how best to include strength items in a mobility measure, or whether it would be more appropriate to design separate measures for each construct.
A verification and validation effort for high explosives at Los Alamos National Lab (u)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scovel, Christina A; Menikoff, Ralph S
2009-01-01
We have started a project to verify and validate ASC codes used to simulate detonation waves in high explosives. Since there are no non-trivial analytic solutions, we are going to compare simulated results with experimental data that cover a wide range of explosive phenomena. The intent is to compare both different codes and different high explosives (HE) models. The first step is to test the products equation of state used for the HE models, For this purpose, the cylinder test, flyer plate and plate-push experiments are being used. These experiments sample different regimes in thermodynamic phase space: the CJ isentropemore » for the cylinder tests, the isentrope behind an overdriven detonation wave for the flyer plate experiment, and expansion following a reflected CJ detonation for the plate-push experiment, which is sensitive to the Gruneisen coefficient. The results of our findings for PBX 9501 are presented here.« less
NASA Astrophysics Data System (ADS)
Delvaux, Damien; Everaerts, Michel; Kongota Isasi, Elvis; Ganza Bamulezi, Gloire
2016-04-01
After the break-up and separation of South America from Africa and the initiation of the South-Atlantic mid-oceanic ridge in the Albian, at about 120 Ma, ridge-push forces started to build-up in the oceanic lithosphere and were transmitted to the adjacent continental plates. This is particularly well expressed in the passive margin and continental interior of Central Africa. According to the relations of Wiens and Stein (1985) between ridge-push forces and basal drag in function of the lithospheric age of oceanic plates, the deviatoric stress reaches a compressional maximum between 50 and 100, Ma after the initiation of the spreading ridge, so broadly corresponding to the Paleocene in this case (~70-20 Ma). Earthquake focal mechanism data show that the West-Congo margin and a large part of the Congo basin are still currently under compressional stresses with an horizontal compression parallel to the direction of the active transform fracture zones. We studied the fracture network along the Congo River in Kinshasa and Brazzaville which affect Cambrian sandstones and probably also the late Cretaceous-Paleocene sediments. Their brittle tectonic evolution is compatible with the buildup of ridge-push forces related to the South-Atlantic opening. Further inland, low-angle reverse faults are found affecting Jurassic to Middle Cretaceous cores from the Samba borehole in the Congo basin and strike-slip movements are recorded as a second brittle phase in the Permian cores of the Dekese well, at the southern margin of the Congo basin. An analysis of the topography and river network of the Congo basin show the development of low-amplitude (50-100 m) long wavelengths (100-300 km) undulations that can be interpreted as lithospheric buckling in response to the compressional intraplate stress field generated by the Mid-Atlantic ridge-push. Wiens, D.A., Stein, S., 1985. Implications of oceanic intraplate seismicity for plate stresses, driving forces and theology. Tectonophysics 1166, 143-162.
Dale, Leila Pfaeffli; White, Lauren; Mitchell, Marc; Faulkner, Guy
2018-04-23
Carrot Rewards is a free, incentive-based, smartphone health app available in participating provinces in Canada. One feature of Carrot was designed to incentivize influenza vaccine education messages and encourage vaccine uptake for users in the province of British Columbia. This study aimed to evaluate the uptake of the Carrot Flu Campaign educational quiz and to determine if mobile "push" notifications, plus loyalty point incentives, resulted in users visiting a sponsored pharmacy to discuss and receive the influenza vaccine. The Carrot Flu Campaign delivered an in-app quiz, educating users on the importance of the influenza vaccine. Push notifications were then sent to users when they came within 200 m of a sponsored pharmacy. Those who visited the pharmacy collected bonus points and completed a follow up quiz tracking influenza vaccine behaviour. A sub-sample of users completed the Flu Campaign between their baseline and follow up Health Risk Assessment (HRA), a survey which asked about influenza vaccine uptake behaviour. Descriptive statistics were summarized. A total of 38.1% (30,538/80,228) registered Carrot users completed the Flu Campaign quiz. Of those in participating cities (n = 21,469), 41% clicked on the map to show the nearest sponsored pharmacy and 78% enabled their smartphone's "locations" feature, allowing them to receive the push notifications. A small number of users spoke to a pharmacist (n = 96) and less than half reported receiving the influenza vaccine (38/96; 39.6%). From the HRA sub-sample (n = 3693), approximately 5% more users reported receiving the influenza vaccine during the 2017 influenza season compared to the previous year. Carrot Rewards used a novel delivery method to educate the general population and showed geolocation could be used to facilitate influenza vaccine uptake. Future iterations could tailor content to target those most at risk and should consider more robust evaluation methods to determine the app's effectiveness. Copyright © 2018 Elsevier Ltd. All rights reserved.
Motor Skills of Obese and Severely Obese Children and Adolescents - A CIRCUIT Study.
Häcker, Anna-Luisa; Bigras, Jean-Luc; Henderson, Mélanie; Barnett, Tracie A; Mathieu, Marie-Eve
2017-11-27
During childhood, excessive weight is negatively associated with the development of motor skills, with children with overweight or obesity having poorer motor skills compared to children with normal weight. The objectives of the current study are to identify the differences in motor skills between children and adolescent with obesity and severe obesity and the extent of this difference. To do so, we examined cross-sectionally 165 subjects. Physical fitness was analyzed in both participants with obesity (>97-99.9 BMI percentile) and severe obesity (>99.9 BMI percentile) using eight standardized tests: sit-and-reach, grip force, sit-ups, push-ups, balance, hand-eye coordination, standing long jump and 5-meter shuttle run. Poorer performance were observed in participants with severe obesity in sit-ups (children: 59%; 18.6±17.0 percentile value vs. 29.5±23.2 percentile value, p=0.008), balance (adolescent: 59%; 12.1±12.2 sec. v. 19.3±13.9 sec., p=0.034) and in the 5-meter shuttle run (children: 49%; 14.0±13.9 percentile value vs. 20.8 ± 19.4 percentile value, p=0.046; adolescents: 11%; 13.2±2.2 sec. vs. 11.8±1.6 sec., p=0.008) compared to obese counterparts. In conclusion, while physical performance was found to be similar between the different obesity levels for the majority of tests, youth with severe obesity demonstrated impairments ranging from 11 to 59% in specific tests.
Pascual-Garrido, Cecilia; Carbo, L; Makino, A
2014-05-01
The purpose of this study is first to report the outcomes, at 4 years follow-up, in revision ACL surgery using allografts in patients younger than 40 years old, and then compared soft tissue allografts to bone tendon allografts. This retrospective study included 47 patients who underwent ACL revision surgery with fresh-frozen allografts. Patellar tendon allograft or tibialis anterior allograft was used. Twenty-seven patients undergoing ACL revision with patellar tendon allograft were compared retrospectively with twenty-two patients undergoing the same procedure with soft tissue tibialis anterior allograft. Lysholm, IKDC, and KT-1000 values were obtained preoperatively and postoperatively. The average patient follow-up was 4.6 years (±2.5). The mean age at time of the revision was 34 years old (±6.3). Overall, patients reported the overall condition of their knee as excellent or good in 85% of the patients (10 excellent, 33 good). Based on their experience, 85% would have the surgery again if they had the same problem in the other knee. Both subgroups experienced significant improvement in Lysholm, IKDC, and KT-1000 values, with no difference found between groups at final follow-up. Revision ACL with allografts has excellent and good results in 85% of patients younger than 40 years old. No statistical difference was seen between soft tissue (tibialis anterior) and patellar tendon allograft. IV.
ERIC Educational Resources Information Center
Ivancevic, Vladimir
2014-01-01
Tests targeting the upper limits of student ability could aid students in their learning. This article gives an overview of an approach to the construction of such tests in programming, together with ideas on how to implement and refine them within a learning management system.
Real Revision: Authors' Strategies to Share with Student Writers
ERIC Educational Resources Information Center
Messner, Kate
2011-01-01
How do you show students that revision is more than a classroom exercise to please the teacher? Take them into the real world of writing for publication. In Real Revision, award-winning author and teacher Kate Messner demystifies the revision process for teachers and students alike and provides tried-and-true revision strategies, field tested by…
Talbot, Laura A; Weinstein, Ali A; Fleg, Jerome L
2009-03-01
An increased rate of cardiac symptoms at combat theater hospitals brings concerns about the predeployment health of Army National Guard (ARNG) soldiers on the basis of older age, lower fitness level, and sedentary lifestyle than active duty troops. The purpose of this study was to examine the association of physical fitness, reported physical activity (PA), and coronary risk factors to calculated 10-year hard coronary heart disease (CHD) risk in 136 ARNG soldiers, aged 18-53 years, who failed the 2-mile run of the Army Physical Fitness Test (APFT). The APFT score, derived from a composite of 2-mile run time, sit-ups, and push-ups, related inversely to 10-year CHD risk (r = -0.23, p < 0.01) but no relationship with CHD risk was observed for PA. APFT scores were positively associated with high-density lipoprotein (HDL) cholesterol and inversely with triglycerides, total cholesterol:HDL ratio, diastolic blood pressure, and body mass index (BMI). No relationship existed between PA and any of the CHD risk factors. We conclude that a higher APFT score is associated with a healthier CHD risk factor profile and is a predictor of better predeployment cardiovascular health.
Muscular and Cardiorespiratory Fitness in Homeschool versus Public School Children.
Kabiri, Laura S; Mitchell, Katy; Brewer, Wayne; Ortiz, Alexis
2017-08-01
The growth and unregulated structure of homeschooling creates an unknown population in regard to muscular and cardiorespiratory fitness. The purpose of this research was to compare muscular and cardiorespiratory fitness between elementary school aged homeschool and public school children. Homeschool children ages 8-11 years old (n = 75) completed the curl-up, 90° push-up, and Progressive Aerobic Capacity Endurance Run (PACER) portions of the FitnessGram to assess abdominal and upper body strength and endurance as well as cardiorespiratory fitness. Comparisons to public school children (n = 75) were made using t tests and chi-square tests. Homeschool children showed significantly lower abdominal (t(148) = -11.441, p < .001; χ 2 (1) = 35.503, p < .001) and upper body (t(148) = -3.610, p < .001; χ 2 (1) = 4.881, p = .027) strength and endurance. There were no significant differences in cardiorespiratory fitness by total PACER laps (t(108) = 0.879, p = .381) or estimated VO 2max (t(70) = 1.187, p = .239; χ 2 (1) = 1.444, p = .486). Homeschool children showed significantly lower levels of both abdominal and upper body muscular fitness compared with their age and gender matched public school peers but no difference in cardiorespiratory fitness.
The Art of Camouflage: When Can a Revision Rhinoplasty Be Nonsurgical?
Kontis, Theda C
2018-06-01
Rhinoplasty surgery is known to have revision rates up to 20%. Surgical revisions include the risk of anesthesia and scarring. The skilled injector may offer nonsurgical alternatives to patients when considering revision surgery. Injections can be done to improve symmetry or improve/camouflage deformities that are possibly too minor for surgery but bothersome to the patient. Injections can be performed using different filler materials, but these treatments also carry inherent risks. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Recycling energy to restore impaired ankle function during human walking.
Collins, Steven H; Kuo, Arthur D
2010-02-17
Humans normally dissipate significant energy during walking, largely at the transitions between steps. The ankle then acts to restore energy during push-off, which may be the reason that ankle impairment nearly always leads to poorer walking economy. The replacement of lost energy is necessary for steady gait, in which mechanical energy is constant on average, external dissipation is negligible, and no net work is performed over a stride. However, dissipation and replacement by muscles might not be necessary if energy were instead captured and reused by an assistive device. We developed a microprocessor-controlled artificial foot that captures some of the energy that is normally dissipated by the leg and "recycles" it as positive ankle work. In tests on subjects walking with an artificially-impaired ankle, a conventional prosthesis reduced ankle push-off work and increased net metabolic energy expenditure by 23% compared to normal walking. Energy recycling restored ankle push-off to normal and reduced the net metabolic energy penalty to 14%. These results suggest that reduced ankle push-off contributes to the increased metabolic energy expenditure accompanying ankle impairments, and demonstrate that energy recycling can be used to reduce such cost.
Dual-Force Vaginoplasty for Treatment of Segmental Vaginal Aplasia.
El Saman, Ali M; Farag, Mohamad A; Shazly, Sherif A; Noor, Mohamed; Ali, Mohammed K; Othman, Essam R; Khalifa, Mansour; Farghly, Tarek A; El Saman, Dina A
2017-05-01
Vaginal aplasia occurs in 1 in 5,000-10,000 female live births. In this report, we evaluated a novel dual-force vaginoplasty technique for treatment of 11 patients with segmental vaginal aplasia. The principle of the approach is to thin the atretic part between two counteracting forces. The instrument was inserted laparoscopically into the proximal hematocolpos. Two balloon catheters, one for drainage and one for traction, were threaded over the inserter. The traction catheter was then threaded over a silicon tube, leaving the balloon in the proximal portion of the vagina and connecting across the vaginal septum to a fenestrated Teflon olive, which was positioned against the distal surface of the vaginal septum. This created a dual "pushing and pulling" force across the septum, which, over 3-4 days, pulls the upper vaginal pouch down while the vaginal dimple is pushed up. The aplastic segment becomes thin and easy to dilate and permits achievement of vaginal patency. The drainage of the hematocolpos is predominantly through the balloon catheter so postoperative wound management is facilitated. Eleven menarchal girls were diagnosed with segmental vaginal aplasia. The dual-force vaginoplasty was performed on each and was tolerated well with no operative complications. They all reported establishment of the menstrual cycle and significant improvement of pain during follow-up. Creation of a dual pushing-pulling force on the atretic vaginal segment is a feasible short procedure for management of segmental vaginal aplasia.
Ultrasonic Coating and Holographic Exposure Technology. Phase 1
2015-09-01
introducing plaques to cure, which allowed the UV lamps to warm up. Temperature inside the UV oven could reach 35 °C if left on continuously. Curing time for...the deposition of thin films using an ultrasonic spray coater and patterning of the films using an ultraviolet ( UV ) laser. The main objectives for...required, and include such items as a corona discharge device, a UV curing oven, hot plate, and jigging for optics that were fabricated at Revision. Test
Measuring mental disorders: The failed commensuration project of DSM-5.
Whooley, Owen
2016-10-01
Commensuration - the comparison of entities according to a common quantitative metric - is a key process in efforts to rationalize medicine. The push toward evidence-based medicine and quantitative assessment has led to the proliferation of metrics in healthcare. While social scientific attention has revealed the effects of these metrics once institutionalized - on clinical practice, on medical expertise, on outcome assessment, on valuations of medical services, and on experiences of illness - less attention has been paid to the process of developing metrics. This article examines the attempt to create severity scales during the revision to the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) as a case of failed commensuration. Using data from interviews with participants in the DSM-5 revision (n = 30), I reconstruct the problems that emerged in the DSM-5 Task Force's effort to develop viable psychometric instruments to measure severity. Framed as a part of a "paradigm shift" in psychiatry, the revision produced ad hoc, heterogeneous severity scales with divergent logics. I focus on two significant issues of metric construction in this case - diagnostic validity and clinical utility. Typically perceived as technical and conceptual challenges of design, I show how these issues were infused with, and undermined by, professional political dynamics, specifically tensions between medical researchers and clinicians. This case reveals that, despite its association with objectivity and transparency, commensuration encompasses more than identifying, operationalizing, and measuring an entity; it demands the negotiation of extra-scientific, non-empirical concerns that get written into medical metrics themselves. Copyright © 2016 Elsevier Ltd. All rights reserved.
Fu, Kai-Ming G; Smith, Justin S; Burton, Douglas C; Kebaish, Khaled M; Shaffrey, Christopher I; Schwab, Frank; Lafage, Virginie; Arlet, Vincent; Hostin, Richard; Boachie, Oheneba; Akbarnia, Behrooz; Bess, Shay
2014-01-01
To evaluate the outcomes and complications of patients with adult spinal deformity treated in a primary versus revision fashion with long fusions to the sacropelvis. A retrospective review was performed of a multicenter consecutive series of patients with adult spinal deformity requiring fusion to the sacropelvis, either primarily or as revision, with minimum 2-year follow-up. Clinical (Scoliosis Research Society [SRS] 22 questionnaire) and radiographic parameters (including sagittal vertical axis [SVA], coronal Cobb angle, lumbar lordosis, and thoracic kyphosis) were compared between the groups. There were 63 patients who met inclusion criteria; mean patient age was 51.9 years, and mean follow-up was 43 months. Patients requiring primary fusion were older (58.0 years vs. 49.5 years, P=0.01) and at baseline had a lower SVA (2.1 cm vs. 6.8 cm, P=0.01) and greater thoracolumbar Cobb angle (51.2 degrees vs. 36.5 degrees, P=0.003). At last follow-up, patients undergoing primary fusion and patients undergoing revision treatment had similar SVA (2.9 cm vs. 1.8 cm, P=0.32) and lumbar lordosis (-42.3 degrees vs. -43.4 degrees, P=0.82); patients undergoing revision treatment had more favorable SRS 22 scores (3.65 vs. 3.14, P=0.005). There was no statistical difference in complication rates between the groups (44.4% vs. 35%, P=0.68). Patients requiring revision extension of instrumentation to the pelvis can be treated with the same expectation of radiographic and clinical success as patients treated primarily with fusion to the sacropelvis. The complication rate for the revision procedure is not insignificant and may be similar to a primary procedure that includes pelvic fixation. Copyright © 2014 Elsevier Inc. All rights reserved.
... and push-ups. There also are special Kegel exercises that help tone the muscles of the pelvic floor. Muscle-strengthening activities should be done in addition to your aerobic activity on at least 2 days a week. When can I start exercising after pregnancy? If you had a healthy pregnancy and a ...
Verma, Diksha; Taneja, Sonali; Kumari, Manju
2018-01-01
Aim: This study aims to evaluate and compare the efficacy of various irrigation regimens on push-out bond strength of AH Plus/gutta-percha, Real Seal/Resilon, and MetaSeal/gutta-percha at three different root levels. Materials and Methods: Single-rooted mandibular premolars (n = 120) were prepared and divided into four groups (n = 30) based on irrigation regimen used: I: 5.25% sodium hypochlorite (NaOCl)-17% ethylenediaminetetraacetic acid (EDTA); II: 5.25% NaOCl-2.25% Peracetic acid (PAA); III: 5.25% NaOCl-18% 1-hydroxyethylidene-1, 1-bisphosphonate (HEBP) (Etidronic Acid); and IV: Distilled Water. Each group was further divided into three subgroups (n = 10); A: AH Plus/gutta-percha; B: MetaSEAL/gutta-percha; C: RealSeal/Resilon. After obturation, roots were sectioned at 3 levels and push-out tests were performed. One-way ANOVA with post hoc Tukey-honestly significant difference tests were applied to assess the significance among various groups. Results: Among irrigants, 2.25% PAA showed significantly lower values when compared with rest of the irrigants. There was no significant difference found among EDTA and HEBP. The push-out bond strength of AH Plus was significantly higher among all sealers. The bond strength values were significantly decreased in apico-coronal direction. Conclusions: There was superior efficacy of EDTA and HEBP on the bond strength of AH Plus at apical root level when compared with other irrigants and sealers at various root levels. PMID:29674811
NASA Technical Reports Server (NTRS)
Jackson, Steven A.
1996-01-01
Modified version of Nylatch (or equivalent) commerical quick-connect/quick-disconnect fastener for joining flat panels. Fastener tightened by pushing on knob on one side and loosened by pushing on knob on other side. Push/push operation of fastener advantageous in cold or otherwise hostile environments where gloves worn, in underwater operations, or if person handicapped.
Age Effects on Wechsler Adult Intelligence Scale-Revised Tests.
ERIC Educational Resources Information Center
Sattler, Jerome M.
1982-01-01
Studied age norms for 11 individual Wechsler Adult Intelligence Scale-Revised (WAIS-R) tests. Digit Symbol showed the most decline. Results suggest that fluid intelligence, as measured by the performance scale tests, shows more of a decline with age than crystallized intelligence, as measured by the verbal scale tests. (Author)
NASA Astrophysics Data System (ADS)
Field, J. A.; Reusser, D. E.; Beller, H. R.; Istok, J. D.
2001-12-01
Obtaining unambiguous evidence of in-situ transformation of benzene, toluene, ethylbenzene and xylene (BTEX) in the subsurface is a difficult task. Recently, benzylsuccinic acid and its methyl analogues were shown to be unequivocal degradation products of anaerobic toluene and xylene biodegradation. Conducting tracer tests at BTEX-contaminated field sites is problematic because background contaminant concentrations potentially interfere with the interpretation of field test data. To avoid the time and cost associated with removing background contaminants, alternative approaches are needed. Deuterated analogs of toluene and xylene are well-suited for use in field tracer tests because they are inexpensive and can be distinguished analytically from background toluene and xylene. In this study, single-well push-pull tests, in which deuterated toluene and xylene were injected, were performed to assess the in-situ anaerobic biotransformation of toluene and xylene in BTEX-contaminated wells. A total of 4 single-well push-pull tests were conducted at BTEX-contaminated field sites near Portland, OR and Kansas City, KS. Test solutions consisting of 100 mg/L bromide, 250 mg/L nitrate, 0.4 to 2.5 mg/L toluene-d8, and 0.4 to 1.0 mg/L o-xylene-d10.were injected at a rate of 0.5 - 2 L/min. During the extraction phase, samples were taken daily to biweekly for up to 30 days. Samples for volatile organic analytes were collected in 40-mL volatile organic analysis (VOA) vials without headspace. Samples for BSA and methyl-BSA were collected in 1 L glass bottles and preserved with 5% (w/w) formalin. Samples were shipped on ice and stored at 4 C until analysis. Unambiguous evidence of toluene and xylene biotransformation was obtained with the in-situ formation of BSA and methyl-BSA. The concentrations of BSA ranged from below the detection limit (0.2 ug/L) to 1.5 ug/L. The concentrations of methyl-BSA ranged from below detection to the quantitation limit (0.7 ug/L). The highest BSA concentrations detected corresponded to 0.1 - 0.2 mol% of the injected deuterated toluene. Zero-order degradation rates for deuterated toluene, estimated as the rates of BSA formation, were 0.0004 to 0.001 day-1. Because methyl-BSA concentrations did not exceed the quantitation limit, the rate of xylene degradation could not be calculated. The formation of BSA and methyl-BSA was coupled with the utilization of nitrate, presumably due to denitrification. Transformation of toluene and xylene to BSA and methyl-BSA, respectively, was observed for wells characterized by low concentrations of toluene and xylene relative to total BTEX. To the best of our knowledge, this is the first report to document the use of deuterated BTEX surrogates in field-tracer experiments.
Hameed, Mustafa Q; Zurakowski, David; Proctor, Mark R; Stone, Scellig S D; Warf, Benjamin C; Smith, Edward R; Goumnerova, Liliana C; Swoboda, Marek; Anor, Tomer; Madsen, Joseph R
2018-06-16
While a noninvasive flow determination would be desirable in the diagnosis of cerebrospinal fluid shunt malfunction, existing studies have not yet defined a role for thermal flow detection. To evaluate a revised test protocol using a micropumper designed to transiently enhance flow during thermal testing to determine whether thermal detection of flow is associated with progression to shunt revision surgery. Eighty-two unique tests were performed in 71 shunts. The primary outcome, need for revision within 7 d of testing, was compared with results of micropumper-augmented thermal flow detection. Statistical analysis was based on blind interpretation of test results and raw temperature data recorded during testing. The test was sensitive (73%) and specific (68%) in predicting need for revision, with 5.6-fold higher probability of revision when flow was not detected. Negative predictive value in our sample was 94.2%. The probability of not requiring revision increased with increasing total temperature drop. Analysis of various possible thresholds showed that the optimal temperature cutoff may be lower than suggested by the manufacturer (0.125°C vs 0.2°C). This is the first study to report a strong association between thermal flow evaluation and a clinical impression that a shunt is not malfunctioning. The current recommended threshold may increase the false positive rate unnecessarily, and as clinicians gain experience with the method, they may find value in examining the temperature curves themselves. Multicenter studies are suggested to further define a role for this diagnostic test.
Manual wheelchair propulsion patterns on natural surfaces during start-up propulsion.
Koontz, Alicia M; Roche, Bailey M; Collinger, Jennifer L; Cooper, Rory A; Boninger, Michael L
2009-11-01
To classify propulsion patterns over surfaces encountered in the natural environment during start-up and compare selected biomechanical variables between pattern types. Case series. National Veterans Wheelchair Games, Minneapolis, MN, 2005. Manual wheelchair users (N=29). Subjects pushed their wheelchairs from a resting position over high-pile carpet, over linoleum, and up a ramp with a 5 degrees incline while propulsion kinematics and kinetics were recorded with a motion capture system and an instrumented wheel. Three raters classified the first 3 strokes as 1 of 4 types on each surface: arc, semicircular (SC), single looping over propulsion (SL), and double looping over propulsion (DL). The Fisher exact test was used to assess pattern changes between strokes and surface type. A multiple analysis of variance test was used to compare peak and average resultant force and moment about the hub, average wheel velocity, stroke frequency, contact angle, and distance traveled between stroke patterns. SL was the most common pattern used during start-up propulsion (44.9%), followed by arc (35.9%), DL (14.1%), and SC (5.1%). Subjects who dropped their hands below the rim during recovery achieved faster velocities and covered greater distances (.016< or =P< or =.075) during start-up on linoleum and carpet and applied more force during start-up on the ramp compared with those who used an arc pattern (P=.066). Classifying propulsion patterns is a difficult task that should use multiple raters. In addition, propulsion patterns change during start-up, with an arc pattern most prevalent initially. The biomechanical findings in this study agree with current clinical guidelines that recommend training users to drop the hand below the pushrim during recovery.
Effects of pushing techniques in birth on mother and fetus: a randomized study.
Yildirim, Gulay; Beji, Nezihe Kizilkaya
2008-03-01
The Valsalva pushing technique is used routinely in the second stage of labor in many countries, and it is accepted as standard obstetric management in Turkey. The purpose of this study was to determine the effects of pushing techniques on mother and fetus in birth in this setting. This randomized study was conducted between July 2003 and June 2004 in Bakirkoy Maternity and Children's Teaching Hospital in Istanbul, Turkey. One hundred low-risk primiparas between 38 and 42 weeks' gestation, who expected a spontaneous vaginal delivery, were randomized to either a spontaneous pushing group or a Valsalva-type pushing group. Spontaneous pushing women were informed during the first stage of labor about spontaneous pushing technique (open glottis pushing while breathing out) and were supported in pushing spontaneously in the second stage of labor. Similarly, Valsalva pushing women were informed during the first stage of labor about the Valsalva pushing technique (closed glottis pushing while holding their breath) and were supported in using Valsalva pushing in the second stage of labor. Perineal tears, postpartum hemorrhage, and hemoglobin levels were evaluated in mothers; and umbilical artery pH, Po(2) (mmHg), and Pco(2) (mmHg) levels and Apgar scores at 1 and 5 minutes were evaluated in newborns in both groups. No significant differences were found between the two groups in their demographics, incidence of nonreassuring fetal surveillance patterns, or use of oxytocin. The second stage of labor and duration of the expulsion phase were significantly longer with Valsalva-type pushing. Differences in the incidence of episiotomy, perineal tears, or postpartum hemorrhage were not significant between the groups. The baby fared better with spontaneous pushing, with higher 1- and 5-minute Apgar scores, and higher umbilical cord pH and Po(2) levels. After the birth, women expressed greater satisfaction with spontaneous pushing. Educating women about the spontaneous pushing technique in the first stage of labor and providing support for spontaneous pushing in the second stage result in a shorter second stage without interventions and in improved newborn outcomes. Women also stated that they pushed more effectively with the spontaneous pushing technique.
Anomalous transport in fracture networks: field scale experiments and modelling
NASA Astrophysics Data System (ADS)
Kang, P. K.; Le Borgne, T.; Bour, O.; Dentz, M.; Juanes, R.
2012-12-01
Anomalous transport is widely observed in different settings and scales of transport through porous and fractured geologic media. A common signature of anomalous transport is the late-time power law tailing in breakthrough curves (BTCs) during tracer tests. Various conceptual models of anomalous transport have been proposed, including multirate mass transfer, continuous time random walk, and stream tube models. Since different conceptual models can produce equally good fits to a single BTC, tracer test interpretation has been plagued with ambiguity. Here, we propose to resolve such ambiguity by analyzing BTCs obtained from both convergent and push-pull flow configurations at two different fracture planes. We conducted field tracer tests in a fractured granite formation close to Ploemeur, France. We observe that BTC tailing depends on the flow configuration and the injection fracture. Specifically the tailing disappears under push-pull geometry, and when we injected at a fracture with high flux (Figure 1). This indicates that for this fractured granite, BTC tailing is controlled by heterogeneous advection and not by matrix diffusion. To explain the change in tailing behavior for different flow configurations, we employ a simple lattice network model with heterogeneous conductivity distribution. The model assigns random conductivities to the fractures and solves the Darcy equation for an incompressible fluid, enforcing mass conservation at fracture intersections. The mass conservation constraint yields a correlated random flow through the fracture system. We investigate whether BTC tailing can be explained by the spatial distribution of preferential flow paths and stagnation zones, which is controlled by the conductivity variance and correlation length. By combining the results from the field tests and numerical modeling, we show that the reversibility of spreading is a key mechanism that needs to be captured. We also demonstrate the dominant role of the injection fracture on the tailing behavior: where we inject makes the difference in the tailing. Blue line is a BTC with injection into a slow velocity zone under convergent flow configuration. The late-time tailing observed for the convergent test diminished for push-pull experiment performed in the same zone(red line). Black line is a BTC with injection into a high velocity zone under convergent flow configuration. Insets: illustration of convergent and push-pull tracer tests using a double packer system.
Faigenbaum, Avery D.; Myer, Gregory D.; Farrell, Anne; Radler, Tracy; Fabiano, Marc; Kang, Jie; Ratamess, Nicholas; Khoury, Jane; Hewett, Timothy E
2014-01-01
Context: Integrative neuromuscular training (INT) has successfully enhanced physical fitness and reduced abnormal biomechanics, which appear to decrease injury rates in adolescent female athletes. If not addressed at the proper time, low levels of physical fitness and abnormal mechanics may predispose female athletes to an increased risk of musculoskeletal injuries. Objectives To evaluate sex-specific effects of INT on selected measures of health- and skill-related fitness in children during physical education (PE). Design: Cohort study. Setting: Public primary school. Patients or Other Participants: Forty children (16 boys, 24 girls; age = 7.6 ± 0.3 years, height = 124.5 ± 6.4 cm, mass = 29.5 ± 7.6 kg) from 2 second-grade PE classes. Intervention(s): The classes were randomized into the PE-plus-INT group (10 boys, 11 girls) or the control group (6 boys, 13 girls) that participated in traditional PE. The INT was performed 2 times per week during the first approximately 15 minutes of each PE class and consisted of body weight exercises. Main Outcome Measure(s): Push-up, curl-up, standing long jump, single-legged hop, single-legged balance, sit-and-reach flexibility test, shuttle run, and 0.8-km run. Results: At baseline, the boys demonstrated higher levels of performance in most of the fitness measurements as evidenced by greater performance on the push-up, standing long jump, single-legged hop, shuttle run, and 0.8-km run (P < .05). In the evaluation of the training effects, we found intervention effects in the girls for enhanced INT-induced gains in performance relative to the control group on the curl-up, long jump, single-legged hop, and 0.8-km run (P < .05) after controlling for baseline. Boys did not demonstrate similar adaptations from the INT program (P ≥ .05). Conclusions: These data indicate that INT is an effective and time-efficient addition to PE for enhancing motor skills and promoting physical activity in children. Seven-year-old girls appeared to be more sensitive to the effects of INT than 7-year-old boys. Future research is warranted to confirm these effects in larger cohorts of children. PMID:24490841
Faigenbaum, Avery D; Myer, Gregory D; Farrell, Anne; Radler, Tracy; Fabiano, Marc; Kang, Jie; Ratamess, Nicholas; Khoury, Jane; Hewett, Timothy E
2014-01-01
Integrative neuromuscular training (INT) has successfully enhanced physical fitness and reduced abnormal biomechanics, which appear to decrease injury rates in adolescent female athletes. If not addressed at the proper time, low levels of physical fitness and abnormal mechanics may predispose female athletes to an increased risk of musculoskeletal injuries. To evaluate sex-specific effects of INT on selected measures of health- and skill-related fitness in children during physical education (PE). Cohort study. Public primary school. Forty children (16 boys, 24 girls; age = 7.6 ± 0.3 years, height = 124.5 ± 6.4 cm, mass = 29.5 ± 7.6 kg) from 2 second-grade PE classes. The classes were randomized into the PE-plus-INT group (10 boys, 11 girls) or the control group (6 boys, 13 girls) that participated in traditional PE. The INT was performed 2 times per week during the first approximately 15 minutes of each PE class and consisted of body weight exercises. Push-up, curl-up, standing long jump, single-legged hop, single-legged balance, sit-and-reach flexibility test, shuttle run, and 0.8-km run. At baseline, the boys demonstrated higher levels of performance in most of the fitness measurements as evidenced by greater performance on the push-up, standing long jump, single-legged hop, shuttle run, and 0.8-km run (P < .05). In the evaluation of the training effects, we found intervention effects in the girls for enhanced INT-induced gains in performance relative to the control group on the curl-up, long jump, single-legged hop, and 0.8-km run (P < .05) after controlling for baseline. Boys did not demonstrate similar adaptations from the INT program (P ≥ .05). These data indicate that INT is an effective and time-efficient addition to PE for enhancing motor skills and promoting physical activity in children. Seven-year-old girls appeared to be more sensitive to the effects of INT than 7-year-old boys. Future research is warranted to confirm these effects in larger cohorts of children.
Validity of Self-Reported Physical Fitness and Body Mass Index in a Military Population.
Martin, Robyn C; Grier, Tyson; Canham-Chervak, Michelle; Anderson, Morgan K; Bushman, Timothy T; DeGroot, David W; Jones, Bruce H
2016-01-01
Many epidemiological studies rely on valid physical fitness data. The purpose of this investigation was to assess the validity of self-reported Army Physical Fitness Test (APFT) data and determine whether men and women recall APFT performance differently. U.S. Army soldiers (N = 1,047) completed a survey, including questions on height, weight, and most recent APFT performance. Height, weight, and APFT performance were also obtained from unit records. The mean ± SDs for unit and self-reported push-up repetitions were 63.5 ± 13.1 and 66.3 ± 14.0 for men and 37.7 ± 12.8 and 40.2 ± 12.8 for women, respectively. The mean ± SD for unit- and self-reported sit-up repetitions were 66.3 ± 11.4 and 68.1 ± 12.1 for men and 64.2 ± 13.6 and 66.5 ± 12.9 for women, respectively. The mean ± SD unit- and self-reported 2-mile run times were 15.2 ± 1.8 and 14.9 ± 1.6 minutes for men, and 18.0 ± 2.9 and 17.4 ± 1.9 minutes for women, respectively. Unit- and self-reported body mass indices (BMIs) (calculated by height and weight) were 26.4 ± 3.4 and 26.3 ± 3.6 for men and 24.6 ± 2.8 and 24.2 ± 3.3 for women. Correlations between unit- and self-reported scores for push-ups, sit-ups, 2-mile run, height, weight, and BMI were 0.82, 0.78, 0.85, 0.87, 0.97, and 0.88 for men and 0.86, 0.84, 0.87, 0.78, 0.98, and 0.78 for women, respectively. On average, men and women slightly overreported performance on the APFT and overestimated height, resulting in underestimated BMI. There was no difference in recall ability between men and women (p > 0.05). The very good to excellent correlations (r = 0.78-0.98) between unit- and self-reported scores indicate that self-reported data are valid for capturing physical fitness performance in this population.
Close up view of switchboard panel operator's station #1; panel ...
Close up view of switchboard panel operator's station #1; panel contains 1200 push-pull button switches which control poer to red, green, and white indicating lights on the model board; white lights indicate that power is off; green lights indicate that equipment (switch breaker or transformer) is off; red lights indicate that equipment is on - Thirtieth Street Station, Power Director Center, Thirtieth & Market Streets in Amtrak Railroad Station, Philadelphia, Philadelphia County, PA
Satisfactory Results of the Exeter Revision Femoral Stem Used for Primary Total Hip Arthroplasty.
Desy, Nicholas M; Johnson, Joshua D; Sierra, Rafael J
2017-02-01
The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship. Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points. The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point. The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired. Copyright © 2016 Elsevier Inc. All rights reserved.
Cai, Pengde; Hu, Yihe; Xie, Lie; Wang, Long
2012-10-01
To investigate the effectiveness of two-stage revision of infected total knee arthroplasty (TKA) using an antibiotic-impregnated articulating cement spacer. The clinical data were analyzed from 23 patients (23 knees) undergoing two-stage revision for late infection after primary TKA between January 2007 and December 2009. There were 15 males and 8 females, aged from 43 to 75 years (mean, 65.2 years). Infection occurred at 13-52 months (mean, 17.3 months) after TKA. The time interval between infection and admission ranged from 15 days to 7 months (mean, 2.1 months). One-stage operation included surgical debridement and removal of all knee prosthesis and cement, then an antibiotic-impregnated articulating cement spacer was implanted. The re-implantation of prosthesis was performed after 8-10 weeks when infections were controlled. The American Hospital for Special Surgery (HSS) score and Knee Society Score (KSS) were used to compare the function of the knee between pre- and post-revision. The rate of infection control and complication were analyzed. All incisions healed primarily. Re-infection occurred in 2 cases after two-stage revision, and infection was controlled in the other 21 cases, with an infection control rate of 91.3%. The patients were followed up 2-5 years (mean, 3.6 years). The HSS score was increased from 60.6 +/- 9.8 at pre-revision to 82.3 +/- 7.4 at last follow-up, the KSS score was increased from 110.7 +/- 9.6 at pre-revision to 134.0 +/- 10.5 at last follow-up, all showing significant differences (P < 0.01). Radiographs showed that prosthesis had good position with no loosening, fracture, or periprosthetic radiolucent. Two-stage revision using an antibiotic-impregnated articulating cement spacer is an effective method to control infected TKA and to restore the function of affected knee.
A reliability analysis of the revised competitiveness index.
Harris, Paul B; Houston, John M
2010-06-01
This study examined the reliability of the Revised Competitiveness Index by investigating the test-retest reliability, interitem reliability, and factor structure of the measure based on a sample of 280 undergraduates (200 women, 80 men) ranging in age from 18 to 28 years (M = 20.1, SD = 2.1). The findings indicate that the Revised Competitiveness Index has high test-retest reliability, high inter-item reliability, and a stable factor structure. The results support the assertion that the Revised Competitiveness Index assesses competitiveness as a stable trait rather than a dynamic state.
Smith, Sheryl M; Coleman, Scott C; Bacon, Stacy A; Polo, Fabian E; Brodsky, James W
2012-06-01
There is limited objective scientific information on the functional effects of cheilectomy. The purpose of this study was to test the hypothesis that cheilectomy for hallux rigidus improves gait by increasing ankle push-off power. Seventeen patients with symptomatic Stage 1 or Stage 2 hallux rigidus were studied. Pre- and postoperative first metatarsophalangeal (MTP) range of motion and AOFAS hallux scores were recorded. A gait analysis was performed within 4 weeks prior to surgery and repeated at a minimum of 1 year after surgery. Gait analysis was done using a three-dimensional motion capture system and a force platform embedded in a 10-m walkway. Gait velocity sagittal plane ankle range of motion and peak sagittal plane ankle push-off power were analyzed. Following cheilectomy, significant increases were noted for first MTP range of motion and AOFAS hallux score. First MTP motion improved an average of 16.7 degrees, from means of 33.9 degrees preoperatively to 50.6 degrees postoperatively (p<0.001). AOFAS hallux score increased from 62 to 81 (p<0.007). As demonstrated through gait anaylsis, a significant increase in postoperative peak sagittal plane ankle push-off power from 1.71±0.92 W/kg to 2.05±0.75 W/kg (p<0.04). In addition to clinically increased range of motion and improved AOFAS Hallux score, first MTP joint cheilectomy produced objective improvement in gait, as measured by increased peak sagittal-plane ankle push-off power.
NASA Astrophysics Data System (ADS)
Hubbard, J.; Almeida, R. V.; Foster, A. E.; Sapkota, S. N.; Burgi, P.; Tapponnier, P.
2016-12-01
The outside layer of the world is broken up into pieces that move. Some of these pieces are moving towards each other. For a very long time, two of these pieces of rock have been pushing together. This has pushed the ground up and has made the highest land in the world. When two big pieces of rock push together, the rocks between them move and change without breaking, because rocks are strong. But eventually, the force is too much, so they break and slip. The place where they slip is called a fault. Try this with a stick - you can force the two ends closer together without breaking it. But if you push the ends together too much, it will snap. Like your stick, when the rocks slip, it happens very suddenly. This makes the ground shake. Last year, the rocks under the highest land in the world broke and slipped. This made the ground shake. Houses and rocks fell down. It killed a lot of people. People knew that this was possible. For years, they have tried to understand how big the shaking might be in this area. To do this, they tried to figure out what the fault looks like. This was hard. They did not agree. They did not know enough about the fault. When the slip happened last year, people used boxes with things inside to learn more about it. Some boxes tell us how the ground moved. Others tell us how the ground shook. We used this to figure out what the fault is like. We think that the fault is made up of different pieces that join together. We colored the fault by how much the rocks slipped. In some places, the rocks slipped only a little bit. In other places, they slipped more than two times as far as a grown-up is tall. When we look at the colors on the fault, we can see that the area that slipped fits onto one piece. The slip stopped at the edges of this piece, where it is joined to other pieces of fault. We think that the way that the pieces of fault are joined controlled how the slip happened. If the slip on a fault stops at the edges of fault pieces both here and in other places, this is important. We need to look all over the world at different faults. We need to learn how the faults are made up of different pieces. Figuring out what controls slip on faults is important. Rocks that break and slip make the ground shake. If we can figure out how much shaking there can be, we can help people get ready. In places where the ground shaking will shake a lot, people can build stronger houses. This will make them safer.
Schröder, Marc L; Staartjes, Victor E
2017-05-01
OBJECTIVE The accuracy of robot-guided pedicle screw placement has been proven to be high, but little is known about the impact of such guidance on clinical outcomes such as the rate of revision surgeries for screw malposition. In addition, there are very few data about the impact of robot-guided fusion on patient-reported outcomes (PROs). Thus, the clinical benefit for the patient is unclear. In this study, the authors analyzed revision rates for screw malposition and changes in PROs following minimally invasive robot-guided pedicle screw fixation. METHODS A retrospective cohort study of patients who had undergone minimally invasive posterior lumbar interbody fusion (MI-PLIF) or minimally invasive transforaminal lumbar interbody fusion was performed. Patients were followed up clinically at 6 weeks, 12 months, and 24 months after treatment and by mailed questionnaire in March 2016 as a final follow-up. Visual analog scale (VAS) scores for back and leg pain severity, Oswestry Disability Index (ODI), screw revisions, and socio-demographic factors were analyzed. A literature review was performed, comparing the incidence of intraoperative screw revisions and revision surgery for screw malposition in robot-guided, navigated, and freehand fusion procedures. RESULTS Seventy-two patients fit the study inclusion criteria and had a mean follow up of 32 ± 17 months. No screws had to be revised intraoperatively, and no revision surgery for screw malposition was needed. In the literature review, the authors found a higher rate of intraoperative screw revisions in the navigated pool than in the robot-guided pool (p < 0.001, OR 9.7). Additionally, a higher incidence of revision surgery for screw malposition was observed for freehand procedures than for the robot-guided procedures (p < 0.001, OR 8.1). The VAS score for back pain improved significantly from 66.9 ± 25.0 preoperatively to 30.1 ± 26.8 at the final follow-up, as did the VAS score for leg pain (from 70.6 ± 22.8 to 24.3 ± 28.3) and ODI (from 43.4 ± 18.3 to 16.2 ± 16.7; all p < 0.001). Undergoing PLIF, a high body mass index, smoking status, and a preoperative ability to work were identified as predictors of a reduction in back pain. Length of hospital stay was 2.4 ± 1.1 days and operating time was 161 ± 50 minutes. Ability to work increased from 38.9% to 78.2% of patients (p < 0.001) at the final follow-up, and 89.1% of patients indicated they would choose to undergo the same treatment again. CONCLUSIONS In adults with low-grade spondylolisthesis, the data demonstrated a benefit in using robotic guidance to reduce the rate of revision surgery for screw malposition as compared with other techniques of pedicle screw insertion described in peer-reviewed publications. Larger comparative studies are required to assess differences in PROs following a minimally invasive approach in spinal fusion surgeries compared with other techniques.
Fed Up with Delays, a President Pushes To Outsource Technology Operations.
ERIC Educational Resources Information Center
Olsen, Florence
2002-01-01
Discusses how officials at Salt Lake Community College decided the only way they could get the kind of technology service they needed was to hire a company to run the operation; the plan will not save money, but seeks better service and room for expansion. (EV)
ERIC Educational Resources Information Center
De Barros, Eric
2013-01-01
Attempting to push early modern presentism to the radical, logical conclusion of a more personal historicism, this essay draws on a number of interpretive practices and theoretical insights--Stephen Greenblatt's self-reflectivity, Toni Morrison's "rememory," Marianne Hirsch's "postmemory," bell hooks's "passion of…
ERIC Educational Resources Information Center
Saunders, Carol Silverman
1997-01-01
After describing what bullying is, the paper presents strategies for dealing with it and helping the "bullies." It focuses on what both parents and teachers can do to reduce and even eliminate bullying. Strategies include: bringing the subject up at PTA and staff meetings, listening openly to children's complaints about bullying, and developing…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-10
... Promulgation of Air Quality Implementation Plans; Colorado; Revisions to Regulation Number 1 AGENCY... Number 1 (revisions to the performance testing requirements for air curtain destructors). Colorado... concurrent with Colorado's Regulation Number 1 revision request will be acted on at a later date. In the...
33 CFR 90.3 - Pushing vessel and vessel being pushed: Composite unit.
Code of Federal Regulations, 2010 CFR
2010-07-01
... pushed: Composite unit. 90.3 Section 90.3 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... vessel being pushed: Composite unit. Rule 24(b) of the Inland Rules states that when a pushing vessel and a vessel being pushed ahead are rigidly connected in a composite unit, they are regarded as a power...
33 CFR 82.3 - Pushing vessel and vessel being pushed: Composite unit.
Code of Federal Regulations, 2010 CFR
2010-07-01
... pushed: Composite unit. 82.3 Section 82.3 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... vessel being pushed: Composite unit. Rule 24(b) of the 72 COLREGS states that when a pushing vessel and a vessel being pushed ahead are rigidly connected in a composite unit, they are regarded as a power-driven...
Importance of positioning for microbial evolution
Kim, Wook; Racimo, Fernando; Schluter, Jonas; Levy, Stuart B.; Foster, Kevin R.
2014-01-01
Microbes commonly live in dense surface-attached communities where cells layer on top of one another such that only those at the edges have unimpeded access to limiting nutrients and space. Theory predicts that this simple spatial effect, akin to plants competing for light in a forest, generates strong natural selection on microbial phenotypes. However, we require direct empirical tests of the importance of this spatial structuring. Here we show that spontaneous mutants repeatedly arise, push their way to the surface, and dominate colonies of the bacterium Pseudomonas fluorescens Pf0-1. Microscopy and modeling suggests that these mutants use secretions to expand and push themselves up to the growth surface to gain the best access to oxygen. Physically mixing the cells in the colony, or introducing space limitations, largely removes the mutant’s advantage, showing a key link between fitness and the ability of the cells to position themselves in the colony. We next follow over 500 independent adaptation events and show that all occur through mutation of a single repressor of secretions, RsmE, but that the mutants differ in competitiveness. This process allows us to map the genetic basis of their adaptation at high molecular resolution and we show how evolutionary competitiveness is explained by the specific effects of each mutation. By combining population level and molecular analyses, we demonstrate how living in dense microbial communities can generate strong natural selection to reach the growing edge. PMID:24715732
Method to determine the optimal constitutive model from spherical indentation tests
NASA Astrophysics Data System (ADS)
Zhang, Tairui; Wang, Shang; Wang, Weiqiang
2018-03-01
The limitation of current indentation theories was investigated and a method to determine the optimal constitutive model through spherical indentation tests was proposed. Two constitutive models, the Power-law and the Linear-law, were used in Finite Element (FE) calculations, and then a set of indentation governing equations was established for each model. The load-depth data from the normal indentation depth was used to fit the best parameters in each constitutive model while the data from the further loading part was compared with those from FE calculations, and the model that better predicted the further deformation was considered the optimal one. Moreover, a Yang's modulus calculation model which took the previous plastic deformation and the phenomenon of pile-up (or sink-in) into consideration was also proposed to revise the original Sneddon-Pharr-Oliver model. The indentation results on six materials, 304, 321, SA508, SA533, 15CrMoR, and Fv520B, were compared with tensile ones, which validated the reliability of the revised E calculation model and the optimal constitutive model determination method in this study.
78 FR 67206 - Qualification Tests for Safety-Related Actuators in Nuclear Power Plants
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-08
... NUCLEAR REGULATORY COMMISSION [NRC-2013-0079] Qualification Tests for Safety-Related Actuators in..., ``Qualification Tests for Safety-Related Actuators in Nuclear Power Plants.'' This RG is being revised to provide... power plants. This RG is proposed Revision 1 of RG 1.73, ``Qualification Tests of Electric Valve...
Revision of OECD Guidelines for Genotoxicity Testing: Current Status and Next Steps
Over the past 30 years, assays have been developed to evaluate chemical genotoxicity. OECD Genotoxicity Test Guidelines (TG) describe assay procedures for regulatory safety testing. Since the last OECD TG revision (1997), there has been tremendous scientific and technological pro...
Anomalous Transport in Single-Well Push-Pull Tracer Tests
NASA Astrophysics Data System (ADS)
Chen, K.; Zhan, H.
2016-12-01
Single-Well Push-Pull (SWPP) tracer test was conducted to estimate the hydraulic and transport properties in a fractured aquifer at Newark basin. A common phenomenon observed for a set of SWPP tests with different incubation time is the heavy tailing of breakthrough curve (BTC) in pumping phase. A novel model with fractional-in-time and (or) -space was developed to interpret the anomalous transport behavior in SWPP tests. The fractal models, including fractional-in-time, fractional-in-space and fractional-in-time-and-space, were solved in radial coordinate using implicit Euler method. A semi-analytical solution of the mobile-immobile (MIM) model was derived as well for comparison purpose. It is found that the fractional-in-space and fractional-in-time-and-space models match the experimental data well. The BTC of the MIM model drops slower than that of the fractional-in-space model at the beginning of pumping and drops much faster at late time. The best match of fractional-in-space model with the experimental data demonstrates that the non-local transport in space plays an important role in SWPP tests conducted in fractured aquifers.
Kellogg, Todd Andrew
2011-12-01
With the increase in bariatric surgical procedures, an increase in revision operations is expected. A thorough preoperative work-up is essential to formulate an appropriate revision strategy. Outcomes vary according to the primary operation and chosen approach to revision. Recent studies have shown acceptably low complication rates and good weight loss with the associated health benefits. Although there is no direct evidence in the form of randomized studies indicating which patients with inadequate weight loss or weight regain will benefit most from revision, or to support one particular revision approach rather than another, it is possible to develop general, effective strategies. Copyright © 2011 Elsevier Inc. All rights reserved.
Revision hip preservation surgery with hip arthroscopy: clinical outcomes.
Domb, Benjamin G; Stake, Christine E; Lindner, Dror; El-Bitar, Youseff; Jackson, Timothy J
2014-05-01
To analyze and report the clinical outcomes of a cohort of patients who underwent revision hip preservation with arthroscopy and determine predictors of positive and negative outcomes. During the study period from April 2008 to December 2010, all patients who underwent revision hip preservation with arthroscopy were included. This included patients who had previous open surgery and underwent revision with arthroscopy. Patient-reported outcome (PRO) scores were obtained preoperatively and at 3-month, 1-year, 2-year, and 3-year follow-up time points. Any revision surgeries and conversions to total hip arthroplasty were noted. A multiple regression analysis was performed to look for positive and negative predictive factors for improvement in PROs after revision hip arthroscopy. Forty-seven hips in 43 patients had completed 2 years' follow-up or needed total hip arthroplasty. The mean length of follow-up was 29 months (range, 24 to 47 months). Of the hips, 31 (66%) had either unaddressed or incompletely treated femoroacetabular impingement. There was a significant improvement in all PRO scores at a mean of 29 months after revision (P < .0001). The visual analog scale score improved from 7.3 ± 1.5 to 3.9 ± 2.5 (P < .0001). Improvements in the Non-Arthritic Hip Score of at least 10 points and 20 points were found in 28 hips (65%) and 19 hips (44%), respectively. Four hips in 3 patients required conversion to total hip arthroplasty. Positive predictive factors for PRO improvement were previous open surgery, pincer impingement, cam impingement, symptomatic heterotopic ossification, and segmental labral defects treated with labral reconstruction. On the basis of multiple PROs, revision hip preservation with hip arthroscopy can achieve moderately successful outcomes and remains a viable treatment strategy after failed primary hip preservation surgery. Preoperative predictors of success after revision hip arthroscopy include segmental labral defects, unaddressed or incompletely addressed femoroacetabular impingement, heterotopic ossification, and previous open surgery. Level IV, therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Pushability and frictional characteristics of medical instruments.
Wünsche, P; Werner, C; Bloss, P
2002-01-01
A tensile testing equipment is combined with a torque module and a 3D force tranducer to characterize the pushability of catheter systems inside modular vessel phantoms. The modular construction of the phantom allows using two dimensional vessel shapes with different contours. Inside the phantom we put a tube or a guide catheter in which the instruments are pushed or redrawn in the presence of a liquid (water, blood, etc.) at body temperature. During pushing or redrawing we measure axial and rotational values. Additionally, friction forces and coefficients are separately determined by using a special designed friction module. First results are presented and discussed.
Reliability of CGA/LGA/HDI Package Board/Assembly (Revision A)
NASA Technical Reports Server (NTRS)
Ghaffarian, Reza
2013-01-01
This follow-up report presents reliability test results conducted by thermal cycling of five CGA assemblies evaluated under two extreme cycle profiles, representative of use for high-reliability applications. The thermal cycles ranged from a low temperature of 55 C to maximum temperatures of either 100 C or 125 C with slow ramp-up rate (3 C/min) and dwell times of about 15 minutes at the two extremes. Optical photomicrographs that illustrate key inspection findings of up to 200 thermal cycles are presented. Other information presented include an evaluation of the integrity of capacitors on CGA substrate after thermal cycling as well as process evaluation for direct assembly of an LGA onto PCB. The qualification guidelines, which are based on the test results for CGA/LGA/HDI packages and board assemblies, will facilitate NASA projects' use of very dense and newly available FPGA area array packages with known reliably and mitigation risks, allowing greater processing power in a smaller board footprint and lower system weight.
Scapular kinematics and muscle activities during pushing tasks.
Huang, Chun-Kai; Siu, Ka-Chun; Lien, Hen-Yu; Lee, Yun-Ju; Lin, Yang-Hua
2013-01-01
Pushing tasks are functional activities of daily living. However, shoulder complaints exist among workers exposed to regular pushing conditions. It is crucial to investigate the control of shoulder girdles during pushing tasks. The objective of the study was to demonstrate scapular muscle activities and motions on the dominant side during pushing tasks and the relationship between scapular kinematics and muscle activities in different pushing conditions. Thirty healthy adults were recruited to push a four-wheel cart in six pushing conditions. The electromyographic signals of the upper trapezius (UT) and serratus anterior (SA) muscles were recorded. A video-based system was used for measuring the movement of the shoulder girdle and scapular kinematics. Differences in scapular kinematics and muscle activities due to the effects of handle heights and weights of the cart were analyzed using two-way ANOVA with repeated measures. The relationships between scapular kinematics and muscle activities were examined by Pearson's correlation coefficients. The changes in upper trapezius and serratus anterior muscle activities increased significantly with increased pushing weights in the one-step pushing phase. The UT/SA ratio on the dominant side decreases significantly with increased handle heights in the one-step pushing phase. The changes in upward rotation, lateral slide and elevation of the scapula decreased with increased pushing loads in the trunk-forward pushing phase. This study indicated that increased pushing loads result in decreased motions of upward rotation, lateral slide and elevation of the scapula; decreased handle heights result in relatively increased activities of the serratus anterior muscles during pushing tasks.
Permeability profiles in granular aquifers using flowmeters in direct-push wells
Paradis, D.; Lefebvre, R.; Morin, R.H.; Gloaguen, E.
2010-01-01
Numerical hydrogeological models should ideally be based on the spatial distribution of hydraulic conductivity (K), a property rarely defined on the basis of sufficient data due to the lack of efficient characterization methods. Electromagnetic borehole flowmeter measurements during pumping in uncased wells can effectively provide a continuous vertical distribution of K in consolidated rocks. However, relatively few studies have used the flowmeter in screened wells penetrating unconsolidated aquifers, and tests conducted in gravel-packed wells have shown that flowmeter data may yield misleading results. This paper describes the practical application of flowmeter profiles in direct-push wells to measure K and delineate hydrofacies in heterogeneous unconsolidated aquifers having low-to-moderate K (10−6 to 10−4 m/s). The effect of direct-push well installation on K measurements in unconsolidated deposits is first assessed based on the previous work indicating that such installations minimize disturbance to the aquifer fabric. The installation and development of long-screen wells are then used in a case study validating Kprofiles from flowmeter tests at high-resolution intervals (15 cm) with K profiles derived from multilevel slug tests between packers at identical intervals. For 119 intervals tested in five different wells, the difference in log K values obtained from the two methods is consistently below 10%. Finally, a graphical approach to the interpretation of flowmeter profiles is proposed to delineate intervals corresponding to distinct hydrofacies, thus providing a method whereby both the scale and magnitude of K contrasts in heterogeneous unconsolidated aquifers may be represented.
Permeability profiles in granular aquifers using flowmeters in direct-push wells.
Paradis, Daniel; Lefebvre, René; Morin, Roger H; Gloaguen, Erwan
2011-01-01
Numerical hydrogeological models should ideally be based on the spatial distribution of hydraulic conductivity (K), a property rarely defined on the basis of sufficient data due to the lack of efficient characterization methods. Electromagnetic borehole flowmeter measurements during pumping in uncased wells can effectively provide a continuous vertical distribution of K in consolidated rocks. However, relatively few studies have used the flowmeter in screened wells penetrating unconsolidated aquifers, and tests conducted in gravel-packed wells have shown that flowmeter data may yield misleading results. This paper describes the practical application of flowmeter profiles in direct-push wells to measure K and delineate hydrofacies in heterogeneous unconsolidated aquifers having low-to-moderate K (10(-6) to 10(-4) m/s). The effect of direct-push well installation on K measurements in unconsolidated deposits is first assessed based on the previous work indicating that such installations minimize disturbance to the aquifer fabric. The installation and development of long-screen wells are then used in a case study validating K profiles from flowmeter tests at high-resolution intervals (15 cm) with K profiles derived from multilevel slug tests between packers at identical intervals. For 119 intervals tested in five different wells, the difference in log K values obtained from the two methods is consistently below 10%. Finally, a graphical approach to the interpretation of flowmeter profiles is proposed to delineate intervals corresponding to distinct hydrofacies, thus providing a method whereby both the scale and magnitude of K contrasts in heterogeneous unconsolidated aquifers may be represented. Journal compilation © 2010 National Ground Water Association. No claim to original US government works.
NASA Astrophysics Data System (ADS)
Le Borgne, T.; Bochet, O.; Klepikova, M.; Kang, P. K.; Shakas, A.; Aquilina, L.; Dufresne, A.; Linde, N.; Dentz, M.; Bour, O.
2016-12-01
Transport processes in fractured media and associated reactions are governed by multiscale heterogeneity ranging from fracture wall roughness at small scale to broadly distributed fracture lengths at network scale. This strong disorder induces a variety of emerging phenomena, including flow channeling, anomalous transport and heat transfer, enhanced mixing and reactive hotspot development. These processes are generally difficult to isolate and monitor in the field because of the high degree of complexity and coupling between them. We report in situ experimental observations from the Ploemeur fractured rock observatory (http://hplus.ore.fr/en/ploemeur) that provide new insights on the dynamics of transport and reaction processes in fractured media. These include dipole and push pull tracer tests that allow understanding and modelling anomalous transport processes characterized by heavy-tailed residence time distributions (Kang et al. 2015), thermal push pull tests that show the existence of highly channeled flow with a strong control on fracture matrix exchanges (Klepikova et al. 2016) and time lapse hydrogeophysical monitoring of saline tracer tests that allow quantifying the distribution of transport length scales governing dispersion processes (Shakas et al. 2016). These transport processes are then shown to induce rapid oxygen delivery and mixing at depth leading to massive biofilm development (Bochet et al., in prep.). Hence, this presentation will attempt to link these observations made at different scales to quantify and model the coupling between flow channeling, non-Fickian transport, mixing and chemical reactions in fractured media. References: Bochet et al. Biofilm blooms driven by enhanced mixing in fractured rock, in prep. Klepikova et al. 2016, Heat as a tracer for understanding transport processes in fractured media: theory and field assessment from multi-scale thermal push-pull tracer tests, Water Resour. Res. 52Shakas et al. 2016, Hydrogeophysical characterization of transport processes in fractured rock by combining push-pull and single-hole ground penetrating radar experiments, Water Resour. Res. 52 Kang et al. 2015, Impact of velocity correlation and distribution on transport in fractured media : Field evidence and theoretical model, Water Resour. Res., 51