Sample records for riser design based

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sterndorff, M.J.; O`Brien, P.

    ROLF (Retrievable Offshore Loading Facility) has been proposed as an alternative offshore oil export tanker loading system for the North Sea. The system consists of a flexible riser ascending from the seabed in a lazy wave configuration to the bow of a dynamically positioned tanker. In order to supplant and support the numerical analyses performed to design the system, an extensive model test program was carried out in a 3D offshore basin at scale 1:50. A model riser with properties equivalent to the properties of the oil filled prototype riser installed in seawater was tested in several combinations of wavesmore » and current. During the tests the forces at the bow of the tanker and at the pipeline end manifold were measured together with the motions of the tanker and the riser. The riser motions were measured by means of a video based 3D motion monitoring system. Of special importance was accurate determination of the minimum bending radius for the riser. This was derived based on the measured riser motions. The results of the model tests were compared to numerical analyses by an MCS proprietary riser analysis program.« less

  2. OTEC riser cable system, Phase II: conceptual design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1980-10-01

    Studies are summarized of conceptual designs of riser cable systems for OTEC pilot plants of both the spar and plantship configurations located at sites off the southeast coast of Puerto Rico. The studies utilize a baseline pilot plant riser cable, the design of which has been developed and reported on in other reports. Baseline riser cable systems for OTEC pilot plants are identified, system hardware consistent with these designs are conceptualized, and comparisons of the various system concepts are provided. It is concluded that there are three riser cable systems feasible for a spar pilot plant platform at the Puntamore » Yeguas site, and two riser cable systems feasible at the plantship pilot plant at the Punta Tuna site. Recommendations for further investigations in the areas of materials, hardware design and pre-installation site surveys are also addressed.« less

  3. 30 CFR 250.910 - Which of my facilities are subject to the Platform Verification Program?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... pipeline risers, and riser tensioning systems (each platform must be designed to accommodate all the loads imposed by all risers and riser does not have tensioning systems);(ii) Turrets and turret-and-hull... Platform Verification Program: (i) Drilling, production, and pipeline risers, and riser tensioning systems...

  4. 30 CFR 250.905 - How do I get approval for the installation, modification, or repair of my platform?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... foundations; drilling, production, and pipeline risers and riser tensioning systems; turrets and turret-and... component design; pile foundations; drilling, production, and pipeline risers and riser tensioning systems... Loads imposed by jacket; decks; production components; drilling, production, and pipeline risers, and...

  5. 30 CFR 250.905 - How do I get approval for the installation, modification, or repair of my platform?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... foundations; drilling, production, and pipeline risers and riser tensioning systems; turrets and turret-and... component design; pile foundations; drilling, production, and pipeline risers and riser tensioning systems... Loads imposed by jacket; decks; production components; drilling, production, and pipeline risers, and...

  6. 30 CFR 250.1002 - Design requirements for DOI pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... of 0.72 for the submerged component and 0.60 for the riser component. E = Longitudinal joint factor... incorporated by reference in 30 CFR 250.198. (5) You must design pipeline risers for tension leg platforms and other floating platforms according to the design standards of API RP 2RD, Design of Risers for Floating...

  7. 30 CFR 250.1002 - Design requirements for DOI pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... of 0.72 for the submerged component and 0.60 for the riser component. E = Longitudinal joint factor... incorporated by reference in 30 CFR 250.198. (5) You must design pipeline risers for tension leg platforms and other floating platforms according to the design standards of API RP 2RD, Design of Risers for Floating...

  8. 30 CFR 250.1002 - Design requirements for DOI pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... of 0.72 for the submerged component and 0.60 for the riser component. E = Longitudinal joint factor... incorporated by reference in 30 CFR 250.198. (5) You must design pipeline risers for tension leg platforms and other floating platforms according to the design standards of API RP 2RD, Design of Risers for Floating...

  9. 30 CFR 250.910 - Which of my facilities are subject to the Platform Verification Program?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., production, and pipeline risers, and riser tensioning systems (each platform must be designed to accommodate all the loads imposed by all risers and riser does not have tensioning systems);(ii) Turrets and... are subject to the Platform Verification Program: (i) Drilling, production, and pipeline risers, and...

  10. 30 CFR 250.910 - Which of my facilities are subject to the Platform Verification Program?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., production, and pipeline risers, and riser tensioning systems (each platform must be designed to accommodate all the loads imposed by all risers and riser does not have tensioning systems);(ii) Turrets and... are subject to the Platform Verification Program: (i) Drilling, production, and pipeline risers, and...

  11. 30 CFR 250.910 - Which of my facilities are subject to the Platform Verification Program?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., production, and pipeline risers, and riser tensioning systems (each platform must be designed to accommodate all the loads imposed by all risers and riser does not have tensioning systems);(ii) Turrets and... are subject to the Platform Verification Program: (i) Drilling, production, and pipeline risers, and...

  12. 30 CFR 250.910 - Which of my facilities are subject to the Platform Verification Program?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., production, and pipeline risers, and riser tensioning systems (each platform must be designed to accommodate all the loads imposed by all risers and riser does not have tensioning systems);(ii) Turrets and... are subject to the Platform Verification Program: (i) Drilling, production, and pipeline risers, and...

  13. Riser Feeding Evaluation Method for Metal Castings Using Numerical Analysis

    NASA Astrophysics Data System (ADS)

    Ahmad, Nadiah

    One of the design aspects that continues to create a challenge for casting designers is the optimum design of casting feeders (risers). As liquid metal solidifies, the metal shrinks and forms cavities inside the casting. In order to avoid shrinkage cavities, risers are added to the casting shape to supply additional molten metal when shrinkage occurs during solidification. The shrinkage cavities in the casting are compensated by controlling the cooling rate to promote directional solidification. This control can be achieved by designing the casting such that the cooling begins at the sections that are farthest away from the risers and ends at the risers. Therefore, the risers will solidify last and feed the casting with the molten metal. As a result, the shrinkage cavities formed during solidification are in the risers which are later removed from the casting. Since casting designers have to usually go through iterative processes of validating the casting designs which are very costly due to expensive simulation processes or manual trials and errors on actual casting processes, this study investigates more efficient methods that will help casting designers utilize their casting experiences systematically to develop good initial casting designs. The objective is to reduce the casting design method iterations; therefore, reducing the cost involved in that design processes. The aim of this research aims at finding a method that can help casting designers design effective risers used in sand casting process of aluminum-silicon alloys by utilizing the analysis of solidification simulation. The analysis focuses on studying the significance of pressure distribution of the liquid metal at the early stage of casting solidification, when heat transfer and convective fluid flow are taken into account in the solidification simulation. The mathematical model of casting solidification was solved using the finite volume method (FVM). This study focuses to improve our understanding of the feeding behavior in aluminum-silicon alloys and the effective feeding by considering the pressure gradient distribution of the molten metal at casting dendrite coherency point. For this study, we will identify the relationship between feeding efficiency, shrinkage behavior and how the change in riser size affects the pressure gradient in the casting. This understanding will be used to help in the design of effective risers.

  14. A fast rise-rate, adjustable-mass-bit gas puff valve for energetic pulsed plasma experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loebner, Keith T. K., E-mail: kloebner@stanford.edu; Underwood, Thomas C.; Cappelli, Mark A.

    2015-06-15

    A fast rise-rate, variable mass-bit gas puff valve based on the diamagnetic repulsion principle was designed, built, and experimentally characterized. The ability to hold the pressure rise-rate nearly constant while varying the total overall mass bit was achieved via a movable mechanical restrictor that is accessible while the valve is assembled and pressurized. The rise-rates and mass-bits were measured via piezoelectric pressure transducers for plenum pressures between 10 and 40 psig and restrictor positions of 0.02-1.33 cm from the bottom of the linear restrictor travel. The mass-bits were found to vary linearly with the restrictor position at a given plenummore » pressure, while rise-rates varied linearly with plenum pressure but exhibited low variation over the range of possible restrictor positions. The ability to change the operating regime of a pulsed coaxial plasma deflagration accelerator by means of altering the valve parameters is demonstrated.« less

  15. Experimental and computational investigations on severe slugging in a catenary riser

    NASA Astrophysics Data System (ADS)

    Duan, Jin-long; Chen, Ke; You, Yun-xiang; Gao, Song

    2017-12-01

    Severe slugging can occur in a pipeline-riser system at relatively low liquid and gas flow rates during gas-oil transportation, possibly causing unexpected damage to the production facilities. Experiments with air and water are conducted in a horizontal and downward inclined pipeline followed by a catenary riser in order to investigate the mechanism and characteristics of severe slugging. A theoretical model is introduced to compare with the experiments. The results show that the formation mechanism of severe slugging in a catenary riser is different from that in a vertical riser due to the riser geometry and five flow patterns are obtained and analyzed. A gas-liquid mixture slug stage is observed at the beginning of one cycle of severe slugging, which is seldom noticed in previous studies. Based on both experiments and computations, the time period and variation of pressure amplitude of severe slugging are found closely related to the superficial gas velocity, implying that the gas velocity significantly influences the flow patterns in our experiments. Moreover, good agreements between the experimental data and the numerical results are shown in the stability curve and flow regime map, which can be a possible reference for design in an offshore oil-production system.

  16. NASA CPAS Drogue Textile Riser Feasibility Study

    NASA Technical Reports Server (NTRS)

    Hennings, Elsa J.; Petersen, Michael L.; Anderson, Brian; Johnson, Brian

    2015-01-01

    Steel cable was chosen for the lower end of the drogue and main parachute risers on NASA's Orion Multi Purpose Crew Vehicle Parachute Assembly System (CPAS) to protect the risers from extreme temperatures and abrasion should they contact the crew module during deployment, as was done for Apollo. Due to the weight and deployment complexity inherent in steel, there was significant interest in the possibility of substituting textile for steel for the drogue and main parachute risers. However, textile risers could be damaged when subjected to high temperature and abrasion. Investigations were consequently performed by a subset of the authors to determine whether sacrificial, non-load-bearing textile riser covers could be developed to mitigate the thermal and abrasion concerns. Multiple material combinations were tested, resulting in a cover design capable of protecting the riser against severe riser/crew module contact interactions. A feasibility study was then conducted to evaluate the performance of the textile drogue riser cover in relevant abrasive environments. This paper describes the testing performed and documents the results of this feasibility study.

  17. Guidelines for riser splash zone design and repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-02-01

    The many years of offshore oil and gas development has established the subsea pipeline as a reliable and cost effective means of transportation for produced hydrocarbons. The requirement for subsea pipeline systems will continue to move into deeper water and more remote locations with the future development of oil and gas exploration. The integrity of subsea pipeline and riser systems, throughout their operating lifetime, is an important area for operators to consider in maximizing reliability and serviceability for economic, contractual and environmental reasons. Adequate design and installation are the basis for ensuring the integrity of any subsea pipeline and risermore » systems. In the event of system damage, from any source, quick and accurate repair and reinstatement of the pipeline system is essential. This report has been developed to provide guidelines for riser and splash zone design, to perform a detailed overview of existing riser repair techniques and products, and to prepare comprehensive guidelines identifying the capabilities and limits of riser reinstatement systems.« less

  18. 30 CFR 250.1007 - What to include in applications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and risers; pressure-regulating devices (including back-pressure regulators); sensing devices with.... (ii) If you propose to use one or more pipeline risers for a tension leg platform or other floating platform, your application must include: (A) The design fatigue life of the riser, with calculations, and...

  19. 30 CFR 250.1007 - What to include in applications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and risers; pressure-regulating devices (including back-pressure regulators); sensing devices with.... (ii) If you propose to use one or more pipeline risers for a tension leg platform or other floating platform, your application must include: (A) The design fatigue life of the riser, with calculations, and...

  20. 30 CFR 250.1007 - What to include in applications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and risers; pressure-regulating devices (including back-pressure regulators); sensing devices with.... (ii) If you propose to use one or more pipeline risers for a tension leg platform or other floating platform, your application must include: (A) The design fatigue life of the riser, with calculations, and...

  1. Dynamic analysis of a circulating fluidized bed riser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panday, Rupen; Shadle, Lawrence J.; Guenther, Chris

    2012-01-01

    A linear state model is proposed to analyze dynamic behavior of a circulating fluidized bed riser. Different operating regimes were attained with high density polyethylene beads at low and high system inventories. The riser was operated between the classical choking velocity and the upper transport velocity demarcating fast fluidized and transport regimes. At a given riser superficial gas velocity, the aerations fed at the standpipe were modulated resulting in a sinusoidal solids circulation rate that goes into the riser via L-valve. The state model was derived based on the mass balance equation in the riser. It treats the average solidsmore » fraction across the entire riser as a state variable. The total riser pressure drop was modeled using Newton’s second law of motion. The momentum balance equation involves contribution from the weight of solids and the wall friction caused by the solids to the riser pressure drop. The weight of solids utilizes the state variable and hence, the riser inventory could be easily calculated. The modeling problem boils down to estimating two parameters including solids friction coefficient and time constant of the riser. It has been shown that the wall friction force acts in the upward direction in fast fluidized regime which indicates that the solids were moving downwards on the average with respect to the riser wall. In transport regimes, the friction acts in the opposite direction. This behavior was quantified based on a sign of Fanning friction factor in the momentum balance equation. The time constant of the riser appears to be much higher in fast fluidized regime than in transport conditions.« less

  2. Robust output feedback stabilization for a flexible marine riser system.

    PubMed

    Zhao, Zhijia; Liu, Yu; Guo, Fang

    2017-12-06

    The aim of this paper is to develop a boundary control for the vibration reduction of a flexible marine riser system in the presence of parametric uncertainties and system states obtained inaccurately. To this end, an adaptive output feedback boundary control is proposed to suppress the riser's vibration fusing with observer-based backstepping, high-gain observers and robust adaptive control theory. In addition, the parameter adaptive laws are designed to compensate for the system parametric uncertainties, and the disturbance observer is introduced to mitigate the effects of external environmental disturbance. The uniformly bounded stability of the closed-loop system is achieved through rigorous Lyapunov analysis without any discretisation or simplification of the dynamics in the time and space, and the state observer error is ensured to exponentially converge to zero as time grows to infinity. In the end, the simulation and comparison studies are carried out to illustrate the performance of the proposed control under the proper choice of the design parameters. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  3. Composite risers for deep-water offshore technology: Problems and prospects. 1. Metal-composite riser

    NASA Astrophysics Data System (ADS)

    Beyle, A. I.; Gustafson, C. G.; Kulakov, V. L.; Tarnopol'skii, Yu. M.

    1997-09-01

    Prospects for the application of advanced composites in the offshore technology of oil production are considered. The use of composites in vertical pipelines-risers seems to be the most efficient. The operating loads are studied and the attendant problems are formulated. A comparative analysis of the characteristics of metal, composite, and metal-composite deep-water risers is presented. A technique is developed for designing multilayered risers, taking into account the action of internal and external pressures, gravity, and the axial tensile force created by tensioners, as well as the residual technological stresses due to the difference in coefficients of thermal expansion, physical-chemical shrinkage, and force winding. Numerical estimations are given for a two-layered riser with an inner metal layer of steel, titanium, or aluminum alloys and a composite layer of glass- or carbon-fiber plastics formed by circumferential winding. It is shown that the technological stresses substantially affect the characteristics of the riser.

  4. 30 CFR 250.916 - What are the CVA's primary duties during the design phase?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Stress analyses; (vi) Material designations; (vii) Soil and foundation conditions; (viii) Safety factors... INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Platforms and... pipeline risers, and riser tensioning systems; (ii) Turrets and turret-and-hull interfaces; (iii...

  5. [Soft-ridged bench terrace design in hilly loess region].

    PubMed

    Cao, Shixiong; Chen, Li; Gao, Wangsheng

    2005-08-01

    Reconfiguration of hillside field into terrace is regarded as one of the key techniques for water and soil conservation in mountainous regions. On slopes exceeding 30 degrees, the traditional techniques of terracing are difficult to apply as risers (i.e., backslopes), and if not reinforced, are so abrupt and easy to collapse under gravity alone, thus damaging the terrace. To improve the reconfiguration of hillside field into terrace, holistic techniques of soft-ridged bench terrace engineering, including revegetation, with trees and planting grasses on riser slopes, were tested between 1997 and 2001 in Xiabiangou watershed of Yan' an, Shaanxi Province. A "working with Nature" engineering approach, riser slopes of 45 degrees, similar to the pre-existing slope of 35 degrees, was employed to radically reduce gravity-erosion. Based on the concepts of biodiversity and the principles of landscape ecology, terrace benches, bunds, and risers were planted with trees, shrubs, forage grasses, and crops, serving to generate a diverse array of plants, a semi-forested area, and to stabilize terrace bunds. Soft-ridged bench terrace made it possible to significantly reduce hazards arising from gravity erosion, and reduce the costs of individual bench construction and maintenance by 24.9% and 55.5% of the costs under traditional techniques, respectively. Such a construction allowed an enrichment and concentration of nutrients in the soils of terrace bunds, providing an ideal environment for a range of plants to grow and develop. The terrace riser could be planted with drought-resistant plants ranging from forage grasses to trees, and this riser vegetation would turn the exposed bunds and risers existing under traditional techniques into plant-covered belts, great green ribbons decorating farmland and contributing to the enhancement of the landscape biology.

  6. Moving from Science to Service: Transposing and Sustaining the Early Risers Prevention Program in a Community Service System

    ERIC Educational Resources Information Center

    Bloomquist, Michael L.; August, Gerald J.; Horowitz, Jason L.; Lee, Susanne S.; Jensen, Cheryl

    2008-01-01

    This paper summarizes an effort to transpose and sustain the evidence-based Early Risers "Skills for Success" conduct problems prevention program in a real world community service system. The Early Risers program had previously been implemented by a local agency within the context of research-based operations. In the current initiative,…

  7. Damage localization of marine risers using time series of vibration signals

    NASA Astrophysics Data System (ADS)

    Liu, Hao; Yang, Hezhen; Liu, Fushun

    2014-10-01

    Based on dynamic response signals a damage detection algorithm is developed for marine risers. Damage detection methods based on numerous modal properties have encountered issues in the researches in offshore oil community. For example, significant increase in structure mass due to marine plant/animal growth and changes in modal properties by equipment noise are not the result of damage for riser structures. In an attempt to eliminate the need to determine modal parameters, a data-based method is developed. The implementation of the method requires that vibration data are first standardized to remove the influence of different loading conditions and the autoregressive moving average (ARMA) model is used to fit vibration response signals. In addition, a damage feature factor is introduced based on the autoregressive (AR) parameters. After that, the Euclidean distance between ARMA models is subtracted as a damage indicator for damage detection and localization and a top tensioned riser simulation model with different damage scenarios is analyzed using the proposed method with dynamic acceleration responses of a marine riser as sensor data. Finally, the influence of measured noise is analyzed. According to the damage localization results, the proposed method provides accurate damage locations of risers and is robust to overcome noise effect.

  8. Crystal accumulation in the Hanford Waste Treatment Plant high level waste melter. Preliminary settling and resuspension testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, K. M.; Fowley, M. D.; Miller, D. H.

    2016-05-01

    The full-scale, room-temperature Hanford Tank Waste Treatment and Immobilization Plant (WTP) High-Level Waste (HLW) melter riser test system was successfully operated with silicone oil and magnetite particles at a loading of 0.1 vol %. Design and construction of the system and instrumentation, and the selection and preparation of simulant materials, are briefly reviewed. Three experiments were completed. A prototypic pour rate was maintained, based on the volumetric flow rate. Settling and accumulation of magnetite particles were observed at the bottom of the riser and along the bottom of the throat after each experiment. The height of the accumulated layer atmore » the bottom of the riser, after the first pouring experiment, approximated the expected level given the solids loading of 0.1 vol %. More detailed observations of particle resuspension and settling were made during and after the third pouring experiment. The accumulated layer of particles at the bottom of the riser appeared to be unaffected after a pouring cycle of approximately 15 minutes at the prototypic flow rate. The accumulated layer of particles along the bottom of the throat was somewhat reduced after the same pouring cycle. Review of the time-lapse recording showed that some of the settling particles flow from the riser into the throat. This may result in a thicker than expected settled layer in the throat.« less

  9. Study and Test of a New Bundle-Structure Riser Stress Monitoring Sensor Based on FBG.

    PubMed

    Xu, Jian; Yang, Dexing; Qin, Chuan; Jiang, Yajun; Sheng, Leixiang; Jia, Xiangyun; Bai, Yang; Shen, Xiaohong; Wang, Haiyan; Deng, Xin; Xu, Liangbin; Jiang, Shiquan

    2015-11-24

    To meet the requirements of riser safety monitoring in offshore oil fields, a new Fiber Bragg Grating (FBG)-based bundle-structure riser stress monitoring sensor has been developed. In cooperation with many departments, a 49-day marine test in water depths of 1365 m and 1252 m was completed on the "HYSY-981" ocean oil drilling platform. No welding and pasting were used when the sensor was installed on risers. Therefore, the installation is convenient, reliable and harmless to risers. The continuous, reasonable, time-consistent data obtained indicates that the sensor worked normally under water. In all detailed working conditions, the test results show that the sensor can do well in reflecting stresses and bending moments both in and in magnitude. The measured maximum stress is 132.7 MPa, which is below the allowable stress. In drilling and testing conditions, the average riser stress was 86.6 MPa, which is within the range of the China National Offshore Oil Corporation (CNOOC) mechanical simulation results.

  10. Study and Test of a New Bundle-Structure Riser Stress Monitoring Sensor Based on FBG

    PubMed Central

    Xu, Jian; Yang, Dexing; Qin, Chuan; Jiang, Yajun; Sheng, Leixiang; Jia, Xiangyun; Bai, Yang; Shen, Xiaohong; Wang, Haiyan; Deng, Xin; Xu, Liangbin; Jiang, Shiquan

    2015-01-01

    To meet the requirements of riser safety monitoring in offshore oil fields, a new Fiber Bragg Grating (FBG)-based bundle-structure riser stress monitoring sensor has been developed. In cooperation with many departments, a 49-day marine test in water depths of 1365 m and 1252 m was completed on the “HYSY-981” ocean oil drilling platform. No welding and pasting were used when the sensor was installed on risers. Therefore, the installation is convenient, reliable and harmless to risers. The continuous, reasonable, time-consistent data obtained indicates that the sensor worked normally under water. In all detailed working conditions, the test results show that the sensor can do well in reflecting stresses and bending moments both in and in magnitude. The measured maximum stress is 132.7 MPa, which is below the allowable stress. In drilling and testing conditions, the average riser stress was 86.6 MPa, which is within the range of the China National Offshore Oil Corporation (CNOOC) mechanical simulation results. PMID:26610517

  11. Drilling Fluid Contamination during Riser Drilling Quantified by Chemical and Molecular Tracers

    NASA Astrophysics Data System (ADS)

    Inagaki, F.; Lever, M. A.; Morono, Y.; Hoshino, T.

    2012-12-01

    Stringent contamination controls are essential to any type of microbiological investigation, and are particularly challenging in ocean drilling, where samples are retrieved from hundreds of meters below the seafloor. In summer 2012, Integrated Ocean Drilling Expedition 337 aboard the Japanese vessel Chikyu pioneered the use of chemical tracers in riser drilling while exploring the microbial ecosystem of coalbeds 2 km below the seafloor off Shimokita, Japan. Contamination tests involving a perfluorocarbon tracer that had been successfully used during past riserless drilling expeditions were complemented by DNA-based contamination tests. In the latter, likely microbial contaminants were targeted via quantitative polymerase chain reaction assays using newly designed, group-specific primers. Target groups included potential indicators of (a) drilling mud viscosifiers (Xanthomonas, Halomonas), (b) anthropogenic wastewater (Bifidobacterium, Blautia, Methanobrevibacter), and (c) surface seawater (SAR 11, Marine Group I Archaea). These target groups were selected based on past evidence suggesting viscosifiers, wastewater, and seawater as the main sources of microbial contamination in cores retrieved by ocean drilling. Analyses of chemical and molecular tracers are in good agreement, and indicate microorganisms associated with mud viscosifiers as the main contaminants during riser drilling. These same molecular analyses are then extended to subseafloor samples obtained during riserless drilling operations. General strategies to further reduce the risk of microbial contamination during riser and riserless drilling operations are discussed.

  12. Riser Difference Uncertainty Methodology Based on Tank AY-101 Wall Thickness Measurements with Application to Tank AN-107

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weier, Dennis R.; Anderson, Kevin K.; Berman, Herbert S.

    2005-03-10

    The DST Integrity Plan (RPP-7574, 2003, Double-Shell Tank Integrity Program Plan, Rev. 1A, CH2M HILL Hanford Group, Inc., Richland, Washington.) requires the ultrasonic wall thickness measurement of two vertical scans of the tank primary wall while using a single riser location. The resulting measurements are then used in extreme value methodology to predict the minimum wall thickness expected for the entire tank. The representativeness of using a single riser in this manner to draw conclusions about the entire circumference of a tank has been questioned. The only data available with which to address the representativeness question comes from Tank AY-101more » since only for that tank have multiple risers been used for such inspection. The purpose of this report is to (1) further characterize AY-101 riser differences (relative to prior work); (2) propose a methodology for incorporating a ''riser difference'' uncertainty for subsequent tanks for which only a single riser is used, and (3) specifically apply the methodology to measurements made from a single riser in Tank AN-107.« less

  13. Early Risers. What Works Clearinghouse Intervention Report

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2012

    2012-01-01

    "Early Risers" is a multi-year prevention program for elementary school children demonstrating early aggressive and disruptive behavior. The intervention model includes two child-focused components and two parent/family components. The Child Skills component is designed to teach skills that enhance children's emotional and behavioral…

  14. Investigation of the motion processes of wastewater in sewerage of high-rise buildings

    NASA Astrophysics Data System (ADS)

    Pomogaeva, Valentina; Metechko, Lyudmila; Prokofiev, Dmitry; Narezhnaya, Tamara

    2018-03-01

    When designing, constructing and operating sewage pipelines in high-rise buildings, issues of failure-free operation of a network arise. Investigation of the processes of wastewater moving allows identifying problem areas during operation, assessing the possibility of obstructions and breakdowns of plumbing traps on the gravity drainage sections of the pipeline. The article performs the schemes of the water outflow from the floor sewer into the riser, including the places where the riser is bent, of air delivery to the working riser under the change of the direction of drain movement with the dropout line set-up, with the installation of an automatic anti-vacuum valve, with the installation of the ventilation pipeline. Investigations of the process of sewage waste flow in a sewage riser were carried out, in order to select the appropriate structure. The authors consider structure features of some sections of sewerage in high-rise buildings. The exhaustion value in the riser is determined from the rarefactions that occur below the compressed cross-section of the riser and the loss of the air flow pressure coming from the atmosphere into the riser during the deflooding of the liquid. Preventing the formation of obstructions and breakdowns of plumbing traps is an integral part of sewage networks.

  15. Jet penetration into a riser operated in dense suspension upflow: experimental and model comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shadle, L.J.; Ludlow, C.J.; Spenik, J.L.

    2008-05-13

    Solids tracers were used to characterize the penetration of a gas-solids jet directed toward the center of the 0.3-m diameter, circulating fluidized bed (CFB) riser. The penetration was measured by tracking phosphorescent particles illuminated immediately prior to injection into the riser. Photosensors and piezoelectric detectors were traversed across the radius of the riser at various axial positions to detect the phosphorescent jet material and particles traveling in the radial direction. Local particle velocities were measured at various radial positions, riser heights, and azimuthal angles using an optical fiber probe. Four (4) variables were tested including the jet velocity, solids feedmore » rate into the jet, the riser velocity, and overall CFB circulation rate over 8 distinct test cases with the central, or base case, repeated each time the test series was conducted. In addition to the experimental measurements made, the entire riser with a side feed jet of solids was simulated using the Eulerian-Eulerian computer model MFIX.« less

  16. Guided-waves technique for inspecting the health of wall-covered building risers

    NASA Astrophysics Data System (ADS)

    Tse, Peter W.; Chen, J. M.; Wan, X.

    2015-03-01

    The inspection technique uses guided ultrasonic waves (GW) has been proven effective in detecting pipes' defects. However, as of today, the technique has not attracted much market attention because of insufficient field tests and lack of traceable records with proven results in commercial applications. In this paper, it presents the results obtained by using GW to inspect the defects occurred in real gas risers that are commonly installed in tall buildings. The purpose of having risers is to deliver gas from any building external piping system to each household unit of the building. The risers extend from the external wall of the building, penetrate thorough the concrete wall, into the kitchen or bathroom of each household unit. Similar to in-service pipes, risers are prone to corrosion due to water leaks into the concrete wall. However, the corrosion occurs in the section of riser, which is covered by the concrete wall, is difficult to be inspected by conventional techniques. Hence, GW technique was employed. The effectiveness of GW technique was tested by laboratory and on-site experiments using real risers gathered from tall buildings. The experimental results show that GW can partially penetrate thorough the riser's section that is covered by wall. The integrity of the wall-covered section of a riser can be determined by the reflected wave signals generated by the corroded area that may exit inside the wall-covered section. Based on the reflected wave signal, one can determine the health of the wall-covered riser.

  17. Flow Regime Study in a Circulating Fluidized Bed Riser with an Abrupt Exit: [1] High Density Suspension

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mei, J.S.; Lee, G.T.; Seachman, S.M.

    2008-05-13

    Flow regime study was conducted in a 0.3 m diameter, 15.5 m tall circulating fluidized bed (CFB) riser with an abrupt exit at the National Energy Technology Laboratory of the U. S. Department of Energy. A statistical designed test series was conducted including four (4) operating set points and a duplicated center point (therefore a total of 6 operating set points). Glass beads of mean diameter 200 μm and particle density of 2,430 kg/m3 were used as bed material. The CFB riser was operated at various superficial gas velocities ranging from 5.6 to 7.6 m/s and solid mass flux frommore » a low of 86 to a high of 303 kg/m2-s. Results of the apparent solids fraction profile as well as the radial particle velocity profile were analyzed in order to identify the presence of Dense Suspension Upflow (DSU) conditions. DSU regime was found to exist at the bottom of the riser, while the middle section of the riser was still exhibiting core-annular flow structure. Due to the abrupt geometry of the exit, the DSU regime was also found at the top of the riser. In addition the effects of the azimuthal angle, riser gas velocity, and mass solids flux on the particle velocity were investigated and are discussed in this paper.« less

  18. Flow Mapping in a Gas-Solid Riser via Computer Automated Radioactive Particle Tracking (CARPT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muthanna Al-Dahhan; Milorad P. Dudukovic; Satish Bhusarapu

    2005-06-04

    Statement of the Problem: Developing and disseminating a general and experimentally validated model for turbulent multiphase fluid dynamics suitable for engineering design purposes in industrial scale applications of riser reactors and pneumatic conveying, require collecting reliable data on solids trajectories, velocities ? averaged and instantaneous, solids holdup distribution and solids fluxes in the riser as a function of operating conditions. Such data are currently not available on the same system. Multiphase Fluid Dynamics Research Consortium (MFDRC) was established to address these issues on a chosen example of circulating fluidized bed (CFB) reactor, which is widely used in petroleum and chemicalmore » industry including coal combustion. This project addresses the problem of lacking reliable data to advance CFB technology. Project Objectives: The objective of this project is to advance the understanding of the solids flow pattern and mixing in a well-developed flow region of a gas-solid riser, operated at different gas flow rates and solids loading using the state-of-the-art non-intrusive measurements. This work creates an insight and reliable database for local solids fluid-dynamic quantities in a pilot-plant scale CFB, which can then be used to validate/develop phenomenological models for the riser. This study also attempts to provide benchmark data for validation of Computational Fluid Dynamic (CFD) codes and their current closures. Technical Approach: Non-Invasive Computer Automated Radioactive Particle Tracking (CARPT) technique provides complete Eulerian solids flow field (time average velocity map and various turbulence parameters such as the Reynolds stresses, turbulent kinetic energy, and eddy diffusivities). It also gives directly the Lagrangian information of solids flow and yields the true solids residence time distribution (RTD). Another radiation based technique, Computed Tomography (CT) yields detailed time averaged local holdup profiles at various planes. Together, these two techniques can provide the needed local solids flow dynamic information for the same setup under identical operating conditions, and the data obtained can be used as a benchmark for development, and refinement of the appropriate riser models. For the above reasons these two techniques were implemented in this study on a fully developed section of the riser. To derive the global mixing information in the riser, accurate solids RTD is needed and was obtained by monitoring the entry and exit of a single radioactive tracer. Other global parameters such as Cycle Time Distribution (CTD), overall solids holdup in the riser, solids recycle percentage at the bottom section of the riser were evaluated from different solids travel time distributions. Besides, to measure accurately and in-situ the overall solids mass flux, a novel method was applied.« less

  19. Experimental Research on the Dense CFB's Riser and the Simulation Based on the EMMS Model

    NASA Astrophysics Data System (ADS)

    Wang, X. Y.; Wang, S. D.; Fan, B. G.; Liao, L. L.; Jiang, F.; Xu, X.; Wu, X. Z.; Xiao, Y. H.

    2010-03-01

    The flow structure in the CFB (circulating fluidized bed) riser has been investigated. Experimental studies were performed in a cold square section unit with 270 mm×270 mm×10 m. Since the drag force model based on homogeneous two-phase flow such as the Gidaspow drag model could not depict the heterogeneous structures of the gas-solid flow, the structure-dependent energy-minimization multi-scale (EMMS) model based on the heterogenerity was applied in the paper and a revised drag force model based on the EMMS model was proposed. A 2D two-fluid model was used to simulate a bench-scale square cross-section riser of a cold CFB. The typical core-annulus structure and the back-mixing near the wall of the riser were observed and the assembly and fragmentation processes of clusters were captured. By comparing with the Gidaspow drag model, the results obtained by the revised drag model based on EMMS shows better consistency with the experimental data. The model can also depict the difference from the two exit configurations. This study once again proves the key role of drag force in CFD (Computational Fluid Dynamics) simulation and also shows the availability of the revised drag model to describe the gas-solid flow in CFB risers.

  20. Dynamic response of a riser under excitation of internal waves

    NASA Astrophysics Data System (ADS)

    Lou, Min; Yu, Chenglong; Chen, Peng

    2015-12-01

    In this paper, the dynamic response of a marine riser under excitation of internal waves is studied. With the linear approximation, the governing equation of internal waves is given. Based on the rigid-lid boundary condition assumption, the equation is solved by Thompson-Haskell method. Thus the velocity field of internal waves is obtained by the continuity equation. Combined with the modified Morison formula, using finite element method, the motion equation of riser is solved in time domain with Newmark-β method. The computation programs are compiled to solve the differential equations in time domain. Then we get the numerical results, including riser displacement and transfiguration. It is observed that the internal wave will result in circular shear flow, and the first two modes have a dominant effect on dynamic response of the marine riser. In the high mode, the response diminishes rapidly. In different modes of internal waves, the deformation of riser has different shapes, and the location of maximum displacement shifts. Studies on wave parameters indicate that the wave amplitude plays a considerable role in response displacement of riser, while the wave frequency contributes little. Nevertheless, the internal waves of high wave frequency will lead to a high-frequency oscillation of riser; it possibly gives rise to fatigue crack extension and partial fatigue failure.

  1. Multifunctional two-stage riser fluid catalytic cracking process.

    PubMed

    Zhang, Jinhong; Shan, Honghong; Chen, Xiaobo; Li, Chunyi; Yang, Chaohe

    This paper described the discovering process of some shortcomings of the conventional fluid catalytic cracking (FCC) process and the proposed two-stage riser (TSR) FCC process for decreasing dry gas and coke yields and increasing light oil yield, which has been successfully applied in 12 industrial units. Furthermore, the multifunctional two-stage riser (MFT) FCC process proposed on the basis of the TSR FCC process was described, which were carried out by the optimization of reaction conditions for fresh feedstock and cycle oil catalytic cracking, respectively, by the coupling of cycle oil cracking and light FCC naphtha upgrading processes in the second-stage riser, and the specially designed reactor for further reducing the olefin content of gasoline. The pilot test showed that it can further improve the product quality, increase the diesel yield, and enhance the conversion of heavy oil.

  2. COMPUTATIONAL MODELING OF CIRCULATING FLUIDIZED BED REACTORS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ibrahim, Essam A

    2013-01-09

    Details of numerical simulations of two-phase gas-solid turbulent flow in the riser section of Circulating Fluidized Bed Reactor (CFBR) using Computational Fluid Dynamics (CFD) technique are reported. Two CFBR riser configurations are considered and modeled. Each of these two riser models consist of inlet, exit, connecting elbows and a main pipe. Both riser configurations are cylindrical and have the same diameter but differ in their inlet lengths and main pipe height to enable investigation of riser geometrical scaling effects. In addition, two types of solid particles are exploited in the solid phase of the two-phase gas-solid riser flow simulations tomore » study the influence of solid loading ratio on flow patterns. The gaseous phase in the two-phase flow is represented by standard atmospheric air. The CFD-based FLUENT software is employed to obtain steady state and transient solutions for flow modulations in the riser. The physical dimensions, types and numbers of computation meshes, and solution methodology utilized in the present work are stated. Flow parameters, such as static and dynamic pressure, species velocity, and volume fractions are monitored and analyzed. The differences in the computational results between the two models, under steady and transient conditions, are compared, contrasted, and discussed.« less

  3. Vector form Intrinsic Finite Element Method for the Two-Dimensional Analysis of Marine Risers with Large Deformations

    NASA Astrophysics Data System (ADS)

    Li, Xiaomin; Guo, Xueli; Guo, Haiyan

    2018-06-01

    Robust numerical models that describe the complex behaviors of risers are needed because these constitute dynamically sensitive systems. This paper presents a simple and efficient algorithm for the nonlinear static and dynamic analyses of marine risers. The proposed approach uses the vector form intrinsic finite element (VFIFE) method, which is based on vector mechanics theory and numerical calculation. In this method, the risers are described by a set of particles directly governed by Newton's second law and are connected by weightless elements that can only resist internal forces. The method does not require the integration of the stiffness matrix, nor does it need iterations to solve the governing equations. Due to these advantages, the method can easily increase or decrease the element and change the boundary conditions, thus representing an innovative concept of solving nonlinear behaviors, such as large deformation and large displacement. To prove the feasibility of the VFIFE method in the analysis of the risers, rigid and flexible risers belonging to two different categories of marine risers, which usually have differences in modeling and solving methods, are employed in the present study. In the analysis, the plane beam element is adopted in the simulation of interaction forces between the particles and the axial force, shear force, and bending moment are also considered. The results are compared with the conventional finite element method (FEM) and those reported in the related literature. The findings revealed that both the rigid and flexible risers could be modeled in a similar unified analysis model and that the VFIFE method is feasible for solving problems related to the complex behaviors of marine risers.

  4. OTEC riser cable model and prototype testing

    NASA Astrophysics Data System (ADS)

    Kurt, J. P.; Schultz, J. A.; Roblee, L. H. S.

    1981-12-01

    Two different OTEC riser cables have been developed to span the distance between a floating OTEC power plant and the ocean floor. The major design concerns for a riser cable in the dynamic OTEC environment are fatigue, corrosion, and electrical/mechanical aging of the cable components. The basic properties of the cable materials were studied through tests on model cables and on samples of cable materials. Full-scale prototype cables were manufactured and were tested to measure their electrical and mechanical properties and performance. The full-scale testing was culminated by the electrical/mechanical fatigue test, which exposes full-scale cables to simultaneous tension, bending and electrical loads, all in a natural seawater environment.

  5. CFD Modeling of a CFB Riser Using Improved Inlet Boundary Conditions

    NASA Astrophysics Data System (ADS)

    Peng, B. T.; Zhang, C.; Zhu, J. X.; Qi, X. B.

    2010-03-01

    A computational fluid dynamics (CFD) model based on Eulerian-Eulerian approach coupled with granular kinetics theory was adopted to investigate the hydrodynamics and flow structures in a circulating fluidized bed (CFB) riser column. A new approach to specify the inlet boundary conditions was proposed in this study to simulate gas-solids flow in CFB risers more accurately. Simulation results were compared with the experimental data, and good agreement between the numerical results and experimental data was observed under different operating conditions, which indicates the effectiveness and accuracy of the CFD model with the proposed inlet boundary conditions. The results also illustrate a clear core annulus structure in the CFB riser under all operating conditions both experimentally and numerically.

  6. Short Sleep Duration is an Independent Predictor of Cardiovascular Events in Japanese Hypertensive Patients

    PubMed Central

    Eguchi, Kazuo; Pickering, Thomas G.; Schwartz, Joseph E.; Hoshide, Satoshi; Ishikawa, Joji; Ishikawa, Shizukiyo; Shimada, Kazuyuki; Kario, Kazuomi

    2013-01-01

    Context It is not known whether short duration of sleep is a predictor of future cardiovascular events in hypertensive patients. Objective To test the hypothesis that short duration of sleep is independently associated with incident cardiovascular diseases (CVD). Design, Setting, and Participants We performed ambulatory BP monitoring (ABPM) in 1255 subjects with hypertension (mean age: 70.4±9.9 years) and they were followed for an average of 50±23 months. Short sleep duration was defined as <7.5 hrs (20th percentile). Multivariable Cox hazard models predicting CVD events were used to estimate the adjusted hazard ratio (HR) and 95% CI for short sleep duration. A riser pattern was defined when average nighttime SBP exceeded daytime SBP. Main Outcome Measures The end point was cardiovascular events: stroke, fatal or non-fatal myocardial infarction (MI), and sudden cardiac death. Results In multivariable analyses, short duration of sleep (<7.5 hrs) was associated with incident CVD (HR=1.68; 1.06–2.66, P=.03). A synergistic interaction was observed between short sleep duration and the riser pattern (P=.089). When subjects were categorized on the basis of their sleep time and riser/non-riser patterns, the shorter sleep+riser group had a substantially and significantly higher incidence of CVD than the predominant normal sleep+non-riser group (HR=4.43;2.09–9.39, P<0.001), independent of covariates. Conclusions Short duration of sleep is associated with incident CVD risk, and the combination of riser pattern and short duration of sleep that is most strongly predictive of future CVD, independent of ambulatory BP levels. Physicians should inquire about sleep duration in the risk assessment of hypertensive patients. PMID:19001199

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    Kongsberg Engineering a.s. has developed an oil loading system for the Central North Sea, in 492-ft waters, which is not permanent, is safer, economical and withstands the environmental forces in the area. The ''Subload'' system is based on loading directly from a seafloor terminal to two 78,000 dwt dynamically positioned shuttle tankers. Upon arrival at the field, a shuttle tanker fitted with an SPM loading yoke and a riser reel deploys a 16-in. flexible riser attached to a lower riser package fitted with thrusters. Controlled by signals from a special high-accuracy underwater maneuver the lower riser end into docking positionmore » with the seafloor terminal. The terminal is located at the end of a two-km, 28-in. pipe line from the production platform. Presentation of the system, the company said that the diverless hookup procedure between the intrument-controlled riser connection and the subsea wellhead requires 45 minutes. The shuttle tanker loading could be completed twice a day in seven and a half hours per operation.« less

  8. Life after High School: Which Postschool Outcomes Matter for Students with and without Disabilities in Restructured High Schools? Research Institute on Secondary Education Reform (RISER) for Youth with Disabilities Brief.

    ERIC Educational Resources Information Center

    Mooney, Marianne; Phelps, L. Allen

    The Research Institute on Secondary Education Reform for Youth with Disabilities (RISER) has been studying three significantly restructured high schools that have included students with disabilities and their parents in the design and/or implementation of school reform efforts. Each of these schools has operated for 3-12 years with its new,…

  9. 30 CFR 250.524 - When am I required to take action from my casing diagnostic test?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .../casing, tubing/riser, casing/casing, riser/casing, or riser/riser communication; (d) Any well that has... initial startup operations described in § 250.521; (e) Any hybrid well with casing or riser pressure...

  10. Holocene slip rate for the central Altyn Tagh Fault: Preliminary results from the Tuzidun site based on 14C and 10Be dating of a displaced fluvial terrace riser.

    NASA Astrophysics Data System (ADS)

    Gold, R. D.; Cowgill, E. S.; Arrowsmith, R.; Muretta, M.; Gosse, J.; Chen, X.; Wang, X.

    2007-12-01

    The active, left-slip Altyn Tagh Fault (ATF) defines the northern boundary of the Tibetan Plateau and is among the world's longest intracontinental strike-slip faults. Despite a decade of concentrated work, the Holocene slip rate for the central ATF is still disputed, with millennial slip rates derived from faulted landforms ranging from 9 to 27 mm/yr. To address this factor-of-three difference, we are investigating a new slip-rate site near Tuzidun (37.73N, 86.72E) along the Cherchen He reach of the fault. The new site is situated where a south-flowing, ephemeral stream channel crosses the N70E-striking, active trace of the ATF. This channel is flanked by a set of inset fluvial terraces along its eastern bank. North of the ATF, these terraces include both a younger/lower T1 tread and an older/higher T2 terrace, which are vertically separated by an intervening T2/T1 riser. South of the fault, the stream is inset into an alluvial fan, F1. The F1 fan is separated from the higher, T2 fluvial terrace tread to the east, by the T2/F1 riser. Our neotectonic mapping and survey data indicate that the T2/F1 riser on the south/downstream side of the ATF and the T2/T1 riser on the north/upstream side have been displaced from one another by left slip along the ATF. The present separation between these riser segments is ~56 m, though lateral erosion of the riser may have diminished the true offset. To account for this possibility, we have developed three end-member reconstructions that yield offsets ranging from 56 to105 m. Ongoing geochronologic and geomorphic analyses are designed further limit the range of possible displacements. Preliminary age analyses from the Tuzidun site include 22 new radiocarbon dates from buried organic materials and 7 analyses of 10Be concentration in quartz extracted from amalgamated samples of terrace conglomerates. The 14C analyses are from samples collected from within the T2 tread on both sides of the ATF and from loess deposits that cap the downstream T2/F1 riser face. The 10Be analyses are from samples collected in two depth profiles, north and south of the ATF, dug into the T2 deposit at the crest of the displaced riser. The calibrated 14C dates and 10Be surface-exposure ages are compatible, and indicate that the surfaces at the crest and toe of the riser were abandoned at ~6 ka and ~4.4 ka, respectively. To bracket the millennial slip rate at this site, we consider three end-member reconstructions. The first is an upper-terrace reconstruction, in which the riser started recording displacement as soon as the upper-terrace, T2, was abandoned, providing a minimum constraint on the slip rate of ~9 mm/yr since ~6 ka. An intermediate interpretation is a lower-terrace reconstruction, in which the riser accumulated no displacement until the lower surface, F1, was abandoned, yielding a slip rate of ~13 mm/yr since ~4.4 ka. The final reconstruction is one in which erosion of the upstream T2 surface, prior to T1/F1 deposition, diminished the present-day observed offset. In this case, up to 105 m of displacement has occurred since abandonment of the T2 surface, which permits a slip rate as high as ~18 mm/yr since ~6 ka. The new slip rate of 9-18 mm/yr for the Tuzidun site is consistent with our preliminary results from three additional slip-rate sites along the central ATF, and taken together, provides an upper limit of 18 mm/yr for the Holocene slip rate along this reach of the fault.

  11. Analysis of the acceleration region in a circulating fluidized bed riser operating above fast fluidization velocities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monazam, E.R.; Shadle, L.J.

    2008-11-05

    In commercial circulating fluidized bed (CFB) processes the acceleration zone greatly contributes to solids mixing, gas and solids dispersion, and particle residence times. A new analysis was developed to describe the relative gas-solids concentration in the acceleration region of a transport system with air as the fluidizing agent for Geldart-type B particles. A theoretical expression was derived from a drag relationship and momentum and continuity equations to describe the evolution of the gas-solids profile along the axial direction. The acceleration zone was characterized using nondimensional analysis of the continuum equations (balances of masses and momenta) that described multiphase flows. Inmore » addition to acceleration length, the boundary condition for the solids fraction at the bottom of the riser and the fully developed regions were measured using an industrial scale CFB of 0.3 m diameter and 15 m tall. The operating factors affecting the flow development in the acceleration region were determined for three materials of various sizes and densities in core annular and dilute regimes of the riser. Performance data were taken from statistically designed experiments over a wide range of Fr (0.5-39), Re (8-600), Ar (29-3600), load ratio (0.2-28), riser to particle diameter ratio (375-5000), and gas to solids density ratio (138-1381). In this one-dimensional system of equations, velocities and solid fractions were assumed to be constant over any cross section. The model and engineering correlations were compared with literature expressions to assess their validity and range of applicability. These expressions can be used as tools for simulation and design of a CFB riser and can also be easily coupled to a kinetics model for process simulation.« less

  12. IODP Expedition 338: NanTroSEIZE Stage 3: NanTroSEIZE plate boundary deep riser 2

    NASA Astrophysics Data System (ADS)

    Moore, G. F.; Kanagawa, K.; Strasser, M.; Dugan, B.; Maeda, L.; Toczko, S.

    2014-01-01

    The Nankai Trough Seismogenic Zone Experiment (NanTroSEIZE) is designed to investigate fault mechanics and seismogenesis along a subduction megathrust, with objectives that include characterizing fault slip, strain accumulation, fault and wall rock composition, fault architecture, and state variables throughout an active plate boundary system. Integrated Ocean Drilling Program (IODP) Expedition 338 was planned to extend and case riser Hole C0002F from 856 to 3600 meters below the seafloor (m b.s.f.). Riser operations extended the hole to 2005.5 m b.s.f., collecting logging-while-drilling (LWD) and measurement-while-drilling, mud gas, and cuttings data. Results reveal two lithologic units within the inner wedge of the accretionary prism that are separated by a prominent fault zone at ~ 1640 m b.s.f. Due to damage to the riser during unfavorable winds and strong currents, riser operations were suspended, and Hole C0002F left for re-entry during future riser drilling operations. Contingency riserless operations included coring at the forearc basin site (C0002) and at two slope basin sites (C0021 and C0022), and LWD at one input site (C0012) and at three slope basin sites (C0018, C0021 and C0022). Cores and logs from these sites comprehensively characterize the alteration stage of the oceanic basement input to the subduction zone, the early stage of Kumano Basin evolution, gas hydrates in the forearc basin, and recent activity of the shallow megasplay fault zone system and associated submarine landslides.

  13. Core disruptive accident margin seal

    DOEpatents

    Garin, John; Belsick, James C.

    1978-01-01

    An apparatus for sealing the annulus defined between a substantially cylindrical rotatable first riser assembly and plug combination disposed in a substantially cylindrical second riser assembly and plug combination of a nuclear reactor system. The apparatus comprises a flexible member disposed between the first and second riser components and attached to a metal member which is attached to an actuating mechanism. When the actuating mechanism is not actuated, the flexible member does not contact the riser components thus allowing the free rotation of the riser components. When desired, the actuating mechanism causes the flexible member to contact the first and second riser components in a manner to block the annulus defined between the riser components, thereby sealing the annulus between the riser components.

  14. Vortex-induced vibration of two parallel risers: Experimental test and numerical simulation

    NASA Astrophysics Data System (ADS)

    Huang, Weiping; Zhou, Yang; Chen, Haiming

    2016-04-01

    The vortex-induced vibration of two identical rigidly mounted risers in a parallel arrangement was studied using Ansys- CFX and model tests. The vortex shedding and force were recorded to determine the effect of spacing on the two-degree-of-freedom oscillation of the risers. CFX was used to study the single riser and two parallel risers in 2-8 D spacing considering the coupling effect. Because of the limited width of water channel, only three different riser spacings, 2 D, 3 D, and 4 D, were tested to validate the characteristics of the two parallel risers by comparing to the numerical simulation. The results indicate that the lift force changes significantly with the increase in spacing, and in the case of 3 D spacing, the lift force of the two parallel risers reaches the maximum. The vortex shedding of the risers in 3 D spacing shows that a variable velocity field with the same frequency as the vortex shedding is generated in the overlapped area, thus equalizing the period of drag force to that of lift force. It can be concluded that the interaction between the two parallel risers is significant when the risers are brought to a small distance between them because the trajectory of riser changes from oval to curve 8 as the spacing is increased. The phase difference of lift force between the two risers is also different as the spacing changes.

  15. Orion Parachute Riser Cutter Development

    NASA Technical Reports Server (NTRS)

    Oguz, Sirri; Salazar, Frank

    2011-01-01

    This paper presents the tests and analytical approach used on the development of a steel riser cutter for the CEV Parachute Assembly System (CPAS) used on the Orion crew module. Figure 1 shows the riser cutter and the steel riser bundle which consists of six individual cables. Due to the highly compressed schedule, initial unavailability of the riser material and the Orion Forward Bay mechanical constraints, JSC primarily relied on a combination of internal ballistics analysis and LS-DYNA simulation for this project. Various one dimensional internal ballistics codes that use standard equation of state and conservation of energy have commonly used in the development of CAD devices for initial first order estimates and as an enhancement to the test program. While these codes are very accurate for propellant performance prediction, they usually lack a fully defined kinematic model for dynamic predictions. A simple piston device can easily and accurately be modeled using an equation of motion. However, the accuracy of analytical models is greatly reduced on more complicated devices with complex external loads, nonlinear trajectories or unique unlocking features. A 3D finite element model of CAD device with all critical features included can vastly improve the analytical ballistic predictions when it is used as a supplement to the ballistic code. During this project, LS-DYNA structural 3D model was used to predict the riser resisting load that was needed for the ballistic code. A Lagrangian model with eroding elements shown in Figure 2 was used for the blade, steel riser and the anvil. The riser material failure strain was fine tuned by matching the dent depth on the anvil with the actual test data. LS-DYNA model was also utilized to optimize the blade tip design for the most efficient cut. In parallel, the propellant type and the amount were determined by using CADPROG internal ballistics code. Initial test results showed a good match with LS-DYNA and CADPROG simulations. Final paper will present a detailed roadmap from initial ballistic modeling and LS-DYNA simulation to the performance testing. Blade shape optimization study will also be presented.

  16. Engineering report for simulated riser installation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brevick, C.H., Westinghouse Hanford

    1996-05-09

    The simulated riser installation field tests demonstrated that new access ports (risers) can be installed safely, quickly, and economically in the concrete domes of existing underground single- shell waste storage tanks by utilizing proven rotary drilling equipment and vacuum excavation techniques. The new riser installation will seal against water intrusion, provide as table riser anchored to the tank dome, and be installed in accordance with ALARA principles. The information contained in the report will apply to actual riser installation activity in the future.

  17. 30 CFR 250.524 - When am I required to take action from my casing diagnostic test?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... psig during a casing diagnostic test; (c) Any well that has demonstrated tubing/casing, tubing/riser, casing/casing, riser/casing, or riser/riser communication; (d) Any well that has sustained casing... operations described in § 250.521; (e) Any hybrid well with casing or riser pressure exceeding 100 psig; or...

  18. 30 CFR 250.525 - When am I required to take action from my casing diagnostic test?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... psig during a casing diagnostic test; (c) Any well that has demonstrated tubing/casing, tubing/riser, casing/casing, riser/casing, or riser/riser communication; (d) Any well that has sustained casing... operations described in § 250.521; (e) Any hybrid well with casing or riser pressure exceeding 100 psig; or...

  19. 30 CFR 250.525 - When am I required to take action from my casing diagnostic test?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... psig during a casing diagnostic test; (c) Any well that has demonstrated tubing/casing, tubing/riser, casing/casing, riser/casing, or riser/riser communication; (d) Any well that has sustained casing... operations described in § 250.521; (e) Any hybrid well with casing or riser pressure exceeding 100 psig; or...

  20. Design and Testing of CPAS Main Deployment Bag Energy Modulator

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2017-01-01

    During the developmental testing program for CPAS (Capsule Parachute Assembly System), the parachute system for the NASA Orion Crew Module, simulation revealed that high loads may be experienced by the pilot risers during the most devere deployment conditions. As the role of the pilot parachutes is to deploy the main parachutes, these high loads introduced the possibility of main deployment failure. In order to mitigate these high loads, a set of energy modulators was incorporated between the pilot riser and the main deployment bag. An extensive developmental program was implemented to ensure the adequacy of these energy modulators. After initial design comparisons, the energy modulator design was validated through slow-speed joint tests as well as through high-speed bungee tests. This paper documents the design, development, and results of multiple tests completed on the final design.

  1. Triggered emissions close to the proton gyrofrequency seen by Cluster

    NASA Astrophysics Data System (ADS)

    Grison, Benjamin; Pickett, Jolene; Omura, Yoshiharu; Santolik, Ondrej; Decreau, Pierrette; Masson, Arnaud; Engebretson, Mark; Cornilleau-Wehrlin, Nicole; Robert, Patrick; Dandouras, Iannis

    Electromagnetic ion cyclotron (EMIC) triggered emissions have been recently observed onboard the Cluster spacecraft close to the plasmapause in the equatorial region of the magnetosphere. These waves appear as "risers": electromagnetic structures that have a positive frequency drift with time, i.e., the EMIC analogue of rising frequency whistler mode triggered emissions and chorus waves. In our first results concerning the emission process based on a single event, these risers have the following properties: they propagate away from the direction of the magnetic equator, they have elliptical left-handed polarization corresponding to the transverse Alfven mode, and frequency drifts of about 30 mHz/s. These risers are not common in the Cluster data set. Nevertheless a few other events were found with similar properties. Another interesting preliminary result is the existence of risers with a polarization opposite that of the EMIC triggered emissions and which correspond to the fast magnetosonic mode.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lv, Q.; Kraus, A.; Hu, R.

    CFD analysis has been focused on important component-level phenomena using STARCCM+ to supplement the system analysis of integral system behavior. A notable area of interest was the cavity region. This area is of particular interest for CFD analysis due to the multi-dimensional flow and complex heat transfer (thermal radiation heat transfer and natural convection), which are not simulated directly by RELAP5. CFD simulations allow for the estimation of the boundary heat flux distribution along the riser tubes, which is needed in the RELAP5 simulations. The CFD results can also provide additional data to help establish what level of modeling detailmore » is necessary in RELAP5. It was found that the flow profiles in the cavity region are simpler for the water-based concept than for the air-cooled concept. The local heat flux noticeably increases axially, and is higher in the fins than in the riser tubes. These results were utilized in RELAP5 simulations as boundary conditions, to provide better temperature predictions in the system level analyses. It was also determined that temperatures were higher in the fins than the riser tubes, but within design limits for thermal stresses. Higher temperature predictions were identified in the edge fins, in part due to additional thermal radiation from the side cavity walls.« less

  3. Refining fault slip rates using multiple displaced terrace risers-An example from the Honey Lake fault, NE California, USA

    NASA Astrophysics Data System (ADS)

    Gold, Ryan D.; Briggs, Richard W.; Crone, Anthony J.; DuRoss, Christopher B.

    2017-11-01

    Faulted terrace risers are semi-planar features commonly used to constrain Quaternary slip rates along strike-slip faults. These landforms are difficult to date directly and therefore their ages are commonly bracketed by age estimates of the adjacent upper and lower terrace surfaces. However, substantial differences in the ages of the upper and lower terrace surfaces (a factor of 2.4 difference observed globally) produce large uncertainties in the slip-rate estimate. In this investigation, we explore how the full range of displacements and bounding ages from multiple faulted terrace risers can be combined to yield a more accurate fault slip rate. We use 0.25-m cell size digital terrain models derived from airborne lidar data to analyze three sites where terrace risers are offset right-laterally by the Honey Lake fault in NE California, USA. We use ages for locally extensive subhorizontal surfaces to bracket the time of riser formation: an upper surface is the bed of abandoned Lake Lahontan having an age of 15.8 ± 0.6 ka and a lower surface is a fluvial terrace abandoned at 4.7 ± 0.1 ka. We estimate lateral offsets of the risers ranging between 6.6 and 28.3 m (median values), a greater than fourfold difference in values. The amount of offset corresponds to the riser's position relative to modern stream meanders: the smallest offset is in a meander cutbank position, whereas the larger offsets are in straight channel or meander point-bar positions. Taken in isolation, the individual terrace-riser offsets yield slip rates ranging from 0.3 to 7.1 mm/a. However, when the offset values are collectively assessed in a probabilistic framework, we find that a uniform (linear) slip rate of 1.6 mm/a (1.4-1.9 mm/a at 95% confidence) can satisfy the data, within their respective uncertainties. This investigation demonstrates that integrating observations of multiple offset elements (crest, midpoint, and base) from numerous faulted and dated terrace risers at closely spaced sites can refine slip-rate estimates on strike-slip faults.

  4. Advances of two-stage riser catalytic cracking of heavy oil for maximizing propylene yield (TMP) process.

    PubMed

    Chaohe, Yang; Xiaobo, Chen; Jinhong, Zhang; Chunyi, Li; Honghong, Shan

    Two-stage riser catalytic cracking of heavy oil for maximizing propylene yield (TMP) process proposed by State Key Laboratory of Heavy oil Processing, China University of Petroleum, can remarkably enhance the propylene yield and minimize the dry gas and coke yields, and obtain high-quality light oils (gasoline and diesel). It has been commercialized since 2006. Up to now, three TMP commercial units have been put into production and other four commercial units are under design and construction. The commercial data showed that taking paraffinic based Daqing (China) atmospheric residue as the feedstock, the propylene yield reached 20.31 wt%, the liquid products yield (the total yield of liquefied petroleum gas, gasoline, and diesel) was 82.66 wt%, and the total yield of dry gas and coke was 14.28 wt%. Moreover, the research octane number of gasoline could be up to 96.

  5. Nonlinear quasi-static analysis of ultra-deep-water top-tension riser

    NASA Astrophysics Data System (ADS)

    Gao, Guanghai; Qiu, Xingqi; Wang, Ke; Liu, Jianjun

    2017-09-01

    In order to analyse the ultra-deep-water top-tension riser deformation in drilling conditions, a nonlinear quasi-static analysis model and equation are established. The riser in this model is regarded as a simply supported beam located in the vertical plane and is subjected to non-uniform axial and lateral forces. The model and the equation are solved by the finite element method. The effects of riser outside diameter, top tension ratio, sea surface current velocity, drag force coefficient, floating system drift distance and water depth on the riser lateral displacement are discussed. Results show that the riser lateral displacement increase with the increase in the sea surface current velocity, drag force coefficient and water depth, whereas decrease with the increase in the riser outside diameter, top tension ratio. The top tension ratio has an important influence on the riser deformation and it should be set reasonably under different circumstances. The drift of the floating system has a complicated influence on the riser deformation and it should avoid a large drift distance in the proceedings of drilling and production.

  6. Structural analysis of color video camera installation on tank 241AW101 (2 Volumes)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strehlow, J.P.

    1994-08-24

    A video camera is planned to be installed on the radioactive storage tank 241AW101 at the DOE` s Hanford Site in Richland, Washington. The camera will occupy the 20 inch port of the Multiport Flange riser which is to be installed on riser 5B of the 241AW101 (3,5,10). The objective of the project reported herein was to perform a seismic analysis and evaluation of the structural components of the camera for a postulated Design Basis Earthquake (DBE) per the reference Structural Design Specification (SDS) document (6). The detail of supporting engineering calculations is documented in URS/Blume Calculation No. 66481-01-CA-03 (1).

  7. Physical simulation of the response of the Enserch Garden Banks 388 FPF/free standing rigid riser to wind, waves, and current

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, R.Y.; Johnson, T.L.; Johnson, R.P.

    1995-12-31

    This paper describes large scale hydrodynamic model tests of the Enserch Exploration Garden Banks 388 Floating Production Facility (FPF). This unique facility consists of a semi-submersible connected to a template on the sea floor 2,096 feet below the surface through a buoyant, free standing ``rigid`` riser. The top of the riser and its manifold are located well below the surface to minimize the forces exerted on the riser by waves. Numerous flexible conductors connect the semi-submersible to the manifold on the top of the riser. The emphasis of the model test program was to confirm the estimates of: The structuralmore » response of the buoyant, rigid production riser and an adjacent drilling riser; The relative displacements between the semisubmersible and the production riser; The relative displacements between the production riser and drilling riser; and The forces which must be endured by the tensioners and flexible hoses which join the semi-submersible to the production riser. The paper describes the planning and preparation of the model components, the unique aspects of the simulation of the environments and the structural properties of the models, the execution of the experiments and the handling of the large number of measurements necessary to characterize the response of the multi-component system. Finally, the data analysis tools which were employed to provide an understanding of the responses of the system are discussed. 22 figs., 1 tab.« less

  8. Core disruptive accident margin seal

    DOEpatents

    Garin, John

    1978-01-01

    An apparatus for sealing the annulus defined between a substantially cylindrical rotatable first riser assembly and plug combination disposed in a substantially cylindrical second riser assembly and plug combination of a nuclear reactor system. The apparatus comprises a flexible metal member having a first side attached to one of the riser components and a second side extending toward the other riser component and an actuating mechanism attached to the flexible metal member while extending to an accessible location. When the actuating mechanism is not activated, the flexible metal member does not contact the other riser component thus allowing the free rotation of the riser assembly and plug combination. When desired, the actuating mechanism causes the second side of the flexible metal member to contact the other riser component thereby sealing the annulus between the components.

  9. A CFD study of gas-solid jet in a CFB riser flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Tingwen; Guenther, Chris

    2012-03-01

    Three-dimensional high-resolution numerical simulations of a gas–solid jet in a high-density riser flow were conducted. The impact of gas–solid injection on the riser flow hydrodynamics was investigated with respect to voidage, tracer mass fractions, and solids velocity distribution. The behaviors of a gas–solid jet in the riser crossflow were studied through the unsteady numerical simulations. Substantial separation of the jetting gas and solids in the riser crossflow was observed. Mixing of the injected gas and solids with the riser flow was investigated and backmixing of gas and solids was evaluated. In the current numerical study, both the overall hydrodynamics ofmore » riser flow and the characteristics of gas–solid jet were reasonably predicted compared with the experimental measurements made at NETL.« less

  10. Computation of turbulence and dispersion of cork in the NETL riser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiradilok, Veeraya; Gidaspow, Dimitri; Breault, R.W.

    The knowledge of dispersion coefficients is essential for reliable design of gasifiers. However, a literature review had shown that dispersion coefficients in fluidized beds differ by more than five orders of magnitude. This study presents a comparison of the computed axial solids dispersion coefficients for cork particles to the NETL riser cork data. The turbulence properties, the Reynolds stresses, the granular temperature spectra and the radial and axial gas and solids dispersion coefficients are computed. The standard kinetic theory model described in Gidaspow’s 1994 book, Multiphase Flow and Fluidization, Academic Press and the IIT and Fluent codes were used tomore » compute the measured axial solids volume fraction profiles for flow of cork particles in the NETL riser. The Johnson–Jackson boundary conditions were used. Standard drag correlations were used. This study shows that the computed solids volume fractions for the low flux flow are within the experimental error of those measured, using a two-dimensional model. At higher solids fluxes the simulated solids volume fractions are close to the experimental measurements, but deviate significantly at the top of the riser. This disagreement is due to use of simplified geometry in the two-dimensional simulation. There is a good agreement between the experiment and the three-dimensional simulation for a high flux condition. This study concludes that the axial and radial gas and solids dispersion coefficients in risers operating in the turbulent flow regime can be computed using a multiphase computational fluid dynamics model.« less

  11. Flow Regime Study in a High Density Circulating Fluidized Bed Riser with an Abrupt Exit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mei, J.S.; Shadle, L.J.; Yue, P.C.

    2007-01-01

    Flow regime study was conducted in a 0.3 m diameter, 15.5 m height circulating fluidized bed (CFB) riser with an abrupt exit at the National Energy Technology Laboratory of the U.S. Department of Energy. Local particle velocities were measured at various radial positions and riser heights using an optical fiber probe. On-line measurement of solid circulating rate was continuously recorded by the Spiral. Glass beads of mean diameter 61 μm and particle density of 2,500 kg/m3 were used as bed material. The CFB riser was operated at various superficial gas velocities ranging from 3 to 7.6 m/s and solid massmore » flux from 20 to 550 kg/m2-s. At a constant riser gas velocity, transition from fast fluidization to dense suspension upflow (DSU) regime started at the bottom of the riser with increasing solid flux. Except at comparatively low riser gas velocity and solid flux, the apparent solid holdup at the top exit region was higher than the middle section of the riser. The solid fraction at this top region could be much higher than 7% under high riser gas velocity and solid mass flux. The local particle velocity showed downward flow near the wall at the top of the riser due to its abrupt exit. This abrupt geometry reflected the solids and, therefore, caused solid particles traveling downward along the wall. However, at location below, but near, the top of the riser the local particle velocities were observed flowing upward at the wall. Therefore, DSU was identified in the upper region of the riser with an abrupt exit while the fully developed region, lower in the riser, was still exhibiting core-annular flow structure. Our data were compared with the flow regime boundaries proposed by Kim et al. [1] for distinguishing the dilute pneumatic transport, fast fluidization, and DSU.« less

  12. Assessment of primary healthcare professionals' management of hypertensive patients with riser pattern.

    PubMed

    Sagarra-Tió, María; Félez-Carrobé, Estel; Baiget, Montserrat; Félez, Jordi

    2015-02-01

    Ambulatory blood pressure monitoring (ABPM) was implemented in our primary care setting four years ago. Since then, 450 ABPMs have been performed and 69 riser subjects identified. The riser pattern is an independent risk factor for both incidence of cardiovascular events and their associated mortality. The purpose of this study was to assess the amount of control of essential hypertension (EH) among riser patients and to evaluate how our health professionals manage therapeutic changes in riser individuals. This retrospective study involved 34,289 inhabitants served in a centre in the Barcelona metropolitan area. EH individuals (450) were recruited and ABPM was performed following guidelines of the MAPAPRES (www.cardiorisc.com/MP/index_MP.asp). Good control of blood pressure was observed in 46% of dipper and non-dipper subjects but only 35% of riser subjects had blood pressures within good control ranges. The measured cardiovascular risk was either high or very high in 35% of riser individuals. Changes in medication were introduced in riser patients with both good and poor blood pressure control. A second follow-up ABPM was done in only 27% of the riser individuals. In these subjects, therapeutic changes successfully modified ABPM patterns in 87% of cases. Therapeutic changes in riser patients were introduced when these subjects were poorly controlled and these changes were highly effective. Additional ABPM to confirm the effectiveness of therapeutic changes was only performed in some individuals. Thus, for management of riser patients, more specific training of health professionals is needed. © The European Society of Cardiology 2013.

  13. System for estimating fatigue damage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LeMonds, Jeffrey; Guzzo, Judith Ann; Liu, Shaopeng

    In one aspect, a system for estimating fatigue damage in a riser string is provided. The system includes a plurality of accelerometers which can be deployed along a riser string and a communications link to transmit accelerometer data from the plurality of accelerometers to one or more data processors in real time. With data from a limited number of accelerometers located at sensor locations, the system estimates an optimized current profile along the entire length of the riser including riser locations where no accelerometer is present. The optimized current profile is then used to estimate damage rates to individual risermore » components and to update a total accumulated damage to individual riser components. The number of sensor locations is small relative to the length of a deepwater riser string, and a riser string several miles long can be reliably monitored along its entire length by fewer than twenty sensor locations.« less

  14. 30 CFR 250.1007 - What to include in applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... line pipe and risers; pressure-regulating devices (including back-pressure regulators); sensing devices... § 250.198), if applicable. (ii) If you propose to use one or more pipeline risers for a tension leg... riser, with calculations, and the fatigue point at which you would replace the riser; (B) The results of...

  15. Maintenance Effects of an Evidence-Based Prevention Innovation for Aggressive Children Living in Culturally Diverse Urban Neighborhoods: The Early Risers Effectiveness Study

    ERIC Educational Resources Information Center

    August, Gerald J.; Lee, Susanne S.; Bloomquist, Michael L.; Realmuto, George M.; Hektner, Joel M.

    2004-01-01

    The present study assessed the ability of the Early Risers' Skills for Success Program to maintain program effects 1 year post intervention. Participants were 327 kindergarten and first-grade children who screened positive for aggressive behavior and who were randomized to program and control conditions. Program children participated in 2…

  16. Promoting workplace stair climbing: sometimes, not interfering is the best.

    PubMed

    Åvitsland, Andreas; Solbraa, Ane Kristiansen; Riiser, Amund

    2017-01-01

    Stair climbing is a vigorous activity and can lead to several health benefits. Studies seeking to increase stair climbing in various public locations have shown positive effects, while results from similar studies conducted in the workplace are inconclusive. This study examined stair climbing in the workplace, and monitored effects from a single- and a combined intervention. Interventions were inspired by nudging, the libertarian method of influencing behavior. By quasi-experimental design, stair- and elevator traffic in two office buildings was monitored preceding-, during- and following interventions with stair leading footprints alone, and combined with stair-riser banners. Chi square tests were applied to determine differences between baseline and the subsequent periods. Web-based questionnaires were distributed after follow-up period. Elevators and stairs were used 45 237 times, of which 89.6% was stair use. Intervention site stair climbing at baseline (79.0%) was significantly reduced with footprints (-5.1%, p <  0.001), and footprints with stair-riser banners (-5.7%, p <  0.001) while baseline stair climbing at the control site (94.2%) remained stable ( p >  0.027). Stair climbing was significantly reduced during the intervention periods. Use of stair leading footprints alone, or combined with stair-riser banners in an attempt to influence stair climbing may be ineffective, or cause a negative reaction, when applied in a workplace with a pre-existing high amount of stair climbing.

  17. Refining fault slip rates using multiple displaced terrace risers—An example from the Honey Lake fault, NE California, USA

    USGS Publications Warehouse

    Gold, Ryan D.; Briggs, Richard; Crone, Anthony J.; Duross, Christopher

    2017-01-01

    Faulted terrace risers are semi-planar features commonly used to constrain Quaternary slip rates along strike-slip faults. These landforms are difficult to date directly and therefore their ages are commonly bracketed by age estimates of the adjacent upper and lower terrace surfaces. However, substantial differences in the ages of the upper and lower terrace surfaces (a factor of 2.4 difference observed globally) produce large uncertainties in the slip-rate estimate. In this investigation, we explore how the full range of displacements and bounding ages from multiple faulted terrace risers can be combined to yield a more accurate fault slip rate. We use 0.25-m cell size digital terrain models derived from airborne lidar data to analyze three sites where terrace risers are offset right-laterally by the Honey Lake fault in NE California, USA. We use ages for locally extensive subhorizontal surfaces to bracket the time of riser formation: an upper surface is the bed of abandoned Lake Lahontan having an age of 15.8 ± 0.6 ka and a lower surface is a fluvial terrace abandoned at 4.7 ± 0.1 ka. We estimate lateral offsets of the risers ranging between 6.6 and 28.3 m (median values), a greater than fourfold difference in values. The amount of offset corresponds to the riser's position relative to modern stream meanders: the smallest offset is in a meander cutbank position, whereas the larger offsets are in straight channel or meander point-bar positions. Taken in isolation, the individual terrace-riser offsets yield slip rates ranging from 0.3 to 7.1 mm/a. However, when the offset values are collectively assessed in a probabilistic framework, we find that a uniform (linear) slip rate of 1.6 mm/a (1.4–1.9 mm/a at 95% confidence) can satisfy the data, within their respective uncertainties. This investigation demonstrates that integrating observations of multiple offset elements (crest, midpoint, and base) from numerous faulted and dated terrace risers at closely spaced sites can refine slip-rate estimates on strike-slip faults.

  18. Prostate specific antigen velocity as a measure of the natural history of prostate cancer: defining a 'rapid riser' subset.

    PubMed

    Nam, R K; Klotz, L H; Jewett, M A; Danjoux, C; Trachtenberg, J

    1998-01-01

    To study the rate of change in prostate specific antigen (PSA velocity) in patients with prostate cancer initially managed by 'watchful waiting'. Serial PSA levels were determined in 141 patients with prostate cancer confirmed by biopsy, who were initially managed expectantly and enrolled between May 1990 and December 1995. Sixty-seven patients eventually underwent surgery (mean age 59 years) because they chose it (the decision for surgery was not based on PSA velocity). A cohort of 74 patients remained on 'watchful waiting' (mean age 69 years). Linear regression and logarithmic transformations were used to segregate those patients who showed a rapid rise, defined as a > 50% rise in PSA per year (or a doubling time of < 2 years) and designated 'rapid risers'. An initial analysis based on a minimum of two PSA values showed that 31% were rapid risers. Only 15% of patients with more than three serial PSA determinations over > or = 6 months showed a rapid rise in PSA level. There was no advantage of log-linear analysis over linear regression models. Three serial PSA determinations over > or = 6 months in patients with clinically localized prostate cancer identifies a subset (15%) of patients with a rapidly rising PSA level. Shorter PSA surveillance with fewer PSA values may falsely identify patients with rapid rises in PSA level. However, further follow-up is required to determine if a rapid rise in PSA level identifies a subset of patients with an aggressive biological phenotype who are either still curable or who have already progressed to incurability through metastatic disease.

  19. Investigation of gas-solids flow in a circulating fluidized bed using 3D electrical capacitance tomography

    NASA Astrophysics Data System (ADS)

    Mao, Mingxu; Ye, Jiamin; Wang, Haigang; Yang, Wuqiang

    2016-09-01

    The hydrodynamics of gas-solids flow in the bottom of a circulating fluidized bed (CFB) are complicated. Three-dimensional (3D) electrical capacitance tomography (ECT) has been used to investigate the hydrodynamics in risers of different shapes. Four different ECT sensors with 12 electrodes each are designed according to the dimension of risers, including two circular ECT sensors, a square ECT sensor and a rectangular ECT sensor. The electrodes are evenly arranged in three planes to obtain capacitance in different heights and to reconstruct the 3D images by linear back projection (LBP) algorithm. Experiments were carried out on the four risers using sands as the solids material. The capacitance and differential pressure are measured under the gas superficial velocity from 0.6 m s-1 to 3.0 m s-1 with a step of 0.2 m s-1. The flow regime is investigated according to the solids concentration and differential pressure. The dynamic property of bubbling flows is analyzed theoretically and the performance of the 3D ECT sensors is evaluated. The experimental results show that 3D ECT can be used in the CFB with different risers to predict the hydrodynamics of gas-solids bubbling flows.

  20. Riser pattern is a predictor of kidney mortality among patients with chronic kidney disease.

    PubMed

    Nakai, Kentaro; Fujii, Hideki; Watanabe, Kentaro; Watanabe, Shuhei; Awata, Rie; Kono, Keiji; Yonekura, Yuriko; Goto, Shunsuke; Nishi, Shinichi

    Hypertension is a crucial risk factor for cardiovascular death and loss of residual kidney function. Absence of the nocturnal decline in blood pressure (BP) predicts cardiovascular events and poor prognosis. However, characteristics of hypertension in moderate-to-severe chronic kidney disease (CKD) have not been fully evaluated. We aimed to assess the circadian variation of BP and kidney survival in CKD patients. Patients who were examined by 24-h ambulatory BP monitoring (ABPM) and estimated glomerular filtration rate (eGFR), <45 ml/min/1.73 m(2), were enrolled in the study. The impacts of BP circadian rhythm and brain natriuretic peptide (BNP) on kidney survival were evaluated. A total of 124 patients were enrolled. The average age was 64 ± 14 years, 57% were male, and 43% had diabetes. Forty-five percent of patients had a non-dipper pattern, 35% had a riser pattern, 19% had a dipper pattern, and 1% had an extreme-dipper pattern. The prevalence of diabetes and plasma BNP levels was higher and eGFR was lower in the riser-pattern group than in the non-riser-pattern group. Kidney survival rates were significantly worse in the riser-pattern group than in the non-riser-pattern group (p < 0.05). Moreover, among riser and non-riser pattern groups divided by BNP levels, the riser group with higher BNP level showed the worst kidney survival (p < 0.05). The riser pattern is frequently associated with several conditions at higher risk for kidney survival. Patients with a rising pattern and higher BNP levels have a worse kidney prognosis.

  1. Acoustic and Perceptual Measures of SATB Choir Performances on Two Types of Portable Choral Riser Units in Three Singer-Spacing Conditions

    ERIC Educational Resources Information Center

    Daugherty, James F.; Manternach, Jeremy N.; Brunkan, Melissa C.

    2013-01-01

    Under controlled conditions, we assessed acoustically (long-term average spectra) and perceptually (singer survey, listener survey) six performances of an soprano, alto, tenor, and bass (SATB) choir ("N" = 27) as it sang the same musical excerpt on two portable riser units (standard riser step height, taller riser step height) with…

  2. Schools of Authentic and Inclusive Learning. Research Institute on Secondary Education Reform (RISER) for Youth with Disabilities Brief.

    ERIC Educational Resources Information Center

    Hanley-Maxwell, Cheryl; Phelps, L. Allen; Braden, Jeff; Warren, Valli

    This brief provides an overview of the foundation and framework for the Research Institute on Secondary Education Reform (RISER) for Youth with Disabilities. RISER focuses on secondary schools engaged in reform efforts that include students with disabilities and seeks to identify restructuring practices that benefit all students. RISERs goal is to…

  3. Characteristics of air-water upward intermittent flows with surfactant additive in a pipeline-riser system

    NASA Astrophysics Data System (ADS)

    Gao, Meng-chen; Xu, Jing-yu

    2018-04-01

    The effect of the surfactant additive on the upward intermittent flows in a pipeline-riser system is studied experimentally, in a 3 m long horizontal pipe connected to a Perspex pipe of 2.0 m long and 25 mm in diameter, inclined to the horizontal plane by 7°, followed by the vertical PVC riser of 3.5 m high and 25 mm in diameter, operating at the atmospheric end pressure. Based on the analysis of the pressure signal and the visual observation of the riser, it is shown that the additive of surfactant to the carrying liquid makes bubbles smaller in size but much larger in number in the upward intermittent flows. In addition, the additive of surfactant to a two-phase flow does not have a significant impact on the in-situ gas fraction, the pressure drop and the frequency of the liquid slug, but it reduces significantly the velocity of the liquid slug. When the superficial liquid velocity is set, an exponential relationship between the dimensionless velocity of the liquid slug and the Webber number can be obtained. These results might be used for estimating the characteristic parameters of the upward intermittent flow based upon the input operating conditions.

  4. Design with constructal theory: Steam generators, turbines and heat exchangers

    NASA Astrophysics Data System (ADS)

    Kim, Yong Sung

    This dissertation shows that the architecture of steam generators, steam turbines and heat exchangers for power plants can be predicted on the basis of the constructal law. According to constructal theory, the flow architecture emerges such that it provides progressively greater access to its currents. Each chapter shows how constructal theory guides the generation of designs in pursuit of higher performance. Chapter two shows the tube diameters, the number of riser tubes, the water circulation rate and the rate of steam production are determined by maximizing the heat transfer rate from hot gases to riser tubes and minimizing the global flow resistance under the fixed volume constraint. Chapter three shows how the optimal spacing between adjacent tubes, the number of tubes for the downcomer and the riser and the location of the flow reversal for the continuous steam generator are determined by the intersection of asymptotes method, and by minimizing the flow resistance under the fixed volume constraints. Chapter four shows that the mass inventory for steam turbines can be distributed between high pressure and low pressure turbines such that the global performance of the power plant is maximal under the total mass constraint. Chapter five presents the more general configuration of a two-stream heat exchanger with forced convection of the hot side and natural circulation on the cold side. Chapter six demonstrates that segmenting a tube with condensation on the outer surface leads to a smaller thermal resistance, and generates design criteria for the performance of multi-tube designs.

  5. Vortex-induced vibration (VIV) effects of a drilling riser due to vessel motion

    NASA Astrophysics Data System (ADS)

    Joseph, R. S.; Wang, J.; Ong, M. C.; Jakobsen, J. B.

    2017-12-01

    A marine riser undergoes oscillatory motion in water due to the vessel motions, known as global dynamic response. This to-and-fro motion of the riser will generate an equivalent flow that can cause Vortex-Induced Vibrations (VIVs), even in the absence of the ocean current. In the present work, full-scale measurement data of a drilling riser operating in the Gulf of Mexico are analysed. The VIV occurrences for the riser are identified from the data and the possible excitation sources are discussed. The oscillatory flow due to vessel motion is compared with the ocean current and its possibility to excite VIV is analysed. The full-scale data analysis provides an insight into the vessel motion-induced VIV of marine risers in the actual field environment.

  6. Twelve years in offshore for Doris C. G

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-04-12

    The offshore engineering operations of Doris have included the design of concrete and steel offshore structures, the design and construction of diving and underwater equipment, offshore equipment, vessels, and heavy mooring systems, and the design and installation of pipelines and risers. The company has also engaged in pipelaying, marine operations, diving, and inspection and maintenance work. Some achievements in 1978 were the completion, tow-out, and installation of the Ninian central platform and the design of an additional riser for the Frigg field manifold compression platform to connect the Piper field to the Frigg gas pipeline. The articulated gravity tower formore » concrete platforms was certified by Norsk Veritas in 1978, but fatigue tests on the articulating ball joint are continuing. New designs include the fixed gravity structure with removable floats, which makes the substructure much smaller, so that concrete platforms become economically feasible in water depths previously considered prohibitive, and the steel-and-concrete hybrid platform, which has been fully developed and certified as safe and economical.« less

  7. The subsea deployment and installation of flexible pipe catenaries for the Enserch Garden Banks 388 Freestanding Production Riser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herman, R.J.

    1997-07-01

    This narrative addresses the development of the subsea flexible pipe catenary handling tools and procedures as used in the Gulf of Mexico on the Enserch Garden Banks 388 Freestanding Production Riser. The philosophy that was invoked for the development of the tools and procedures was targeted on long term utilization and field maintenance capability with minimum vessel relocation requirements and minimum production interruptions. The initial emphasis for the required tools and procedures was to develop worker safe, environmentally friendly and cost effective equipment. These tools are for the deployment and installation of 3-inch Production and Annulus flexible pipe catenaries frommore » the Enserch Garden Banks 388 Floating Production Vessel to the system`s Freestanding Production Riser. The Pull In Jib system is common to the handling of all the catenaries. The Pull In Jib system has been designed to support the greater loads of the 8-inch and 12-inch export line catenaries.« less

  8. Promoting stair use: single versus multiple stair-riser messages.

    PubMed

    Webb, Oliver J; Eves, Frank F

    2005-09-01

    Message banners attached to stair risers produced a significant increase in pedestrian stair use, exceeding effects previously reported for conventional posters. Multiple instances of the same message banner, however, were as effective as banners featuring different messages. Therefore, greater visibility, rather than message variety, appears to account for the superiority of the banner format. Our findings indicate the feasibility of simple stair-use promotion campaigns based around the repetition of a single message.

  9. Garden Banks 388 deepwater production riser structural and environmental monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thrall, D.E.; Pokladnik, R.L.

    1995-12-01

    A deepwater production riser, to be installed in 1995 in Garden Banks 388 in the Gulf of Mexico, has been instrumented with bonded resistance strain gages so that the remaining operational fatigue life can be quantified. The riser supports flowlines from subsea oil and gas wells to a floating combination drilling/production vessel, and thus is fixed at its lower end and free to move at its upper terminus. The distribution of bending stresses throughout the riser, which is attached to a template at 2,096 foot depth and extends to within 150 feet of the surface, reaches a maximum at themore » bottom. The riser is instrumented with strain gages, inclinometers, and accelerometers at five locations along its length so that tension, bending, orientation, and motion of the riser can be monitored at these locations, including the bottom joint. Correlation of the riser response data with the excitation or environmental data, including wave motion, current velocities, wind velocities, and vessel mooring tensions and positions is enhanced by acquiring and archiving all data on a single common system having multiple redundant elements for reliability. This paper describes the production riser structural and environmental monitoring system used on the Garden Banks 388 project.« less

  10. 46 CFR 151.50-5 - Cargoes having toxic properties.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... vent riser shall extend at least 12 feet above the highest level accessible to personnel. The vent riser may be collapsible for ease of stowage when not in use. Vapor return lines or vent risers for...

  11. 30 CFR 250.917 - What are the CVA's primary duties during the fabrication phase?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... overall structure, including any turrets, turret-and-hull interfaces, any mooring line and chain and riser... must also consider: (i) Drilling, production, and pipeline risers, and riser tensioning systems (at...

  12. 46 CFR 151.50-5 - Cargoes having toxic properties.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... vent riser shall extend at least 12 feet above the highest level accessible to personnel. The vent riser may be collapsible for ease of stowage when not in use. Vapor return lines or vent risers for...

  13. 30 CFR 250.917 - What are the CVA's primary duties during the fabrication phase?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... turrets, turret-and-hull interfaces, any mooring line and chain and riser tensioning line segments; and...) Drilling, production, and pipeline risers, and riser tensioning systems (at least for the initial...

  14. 46 CFR 151.50-5 - Cargoes having toxic properties.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... vent riser shall extend at least 12 feet above the highest level accessible to personnel. The vent riser may be collapsible for ease of stowage when not in use. Vapor return lines or vent risers for...

  15. 46 CFR 151.50-5 - Cargoes having toxic properties.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... vent riser shall extend at least 12 feet above the highest level accessible to personnel. The vent riser may be collapsible for ease of stowage when not in use. Vapor return lines or vent risers for...

  16. 30 CFR 250.917 - What are the CVA's primary duties during the fabrication phase?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... turrets, turret-and-hull interfaces, any mooring line and chain and riser tensioning line segments; and...) Drilling, production, and pipeline risers, and riser tensioning systems (at least for the initial...

  17. 46 CFR 151.50-5 - Cargoes having toxic properties.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... vent riser shall extend at least 12 feet above the highest level accessible to personnel. The vent riser may be collapsible for ease of stowage when not in use. Vapor return lines or vent risers for...

  18. 30 CFR 250.917 - What are the CVA's primary duties during the fabrication phase?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... turrets, turret-and-hull interfaces, any mooring line and chain and riser tensioning line segments; and...) Drilling, production, and pipeline risers, and riser tensioning systems (at least for the initial...

  19. A biomechanical evaluation of staircase riser heights and tread depths during stair-climbing.

    PubMed

    Mital, A; Fard, H F; Khaledi, H

    1987-08-01

    Several different staircase riser heights and tread depths were investigated in order to determine riser height and tread depth that minimized moments acting at the ankle, knee, and hipjoints while walking upstairs. The results indicated that joint moments were minimized when the riser height was 102 mm. For the tread depth, least moments were obtained when the depth was 305 mm. Copyright © 1987. Published by Elsevier Ltd.

  20. Riser Blood Pressure Pattern Is Associated With Mild Cognitive Impairment in Heart Failure Patients.

    PubMed

    Komori, Takahiro; Eguchi, Kazuo; Saito, Toshinobu; Nishimura, Yoshioki; Hoshide, Satoshi; Kario, Kazuomi

    2016-02-01

    The riser pattern, an abnormal blood pressure (BP) rhythm in which sleep BP exceeds awake BP, is a predictor of future stroke events. Although the riser pattern is caused by autonomic dysfunction, its significance in heart failure (HF) patients is not established. HF patients often suffered from cognitive impairment (CI), but the relationship between riser pattern and CI is not clearly understood. We tested the hypothesis that the riser pattern is associated with mild CI, a form of brain damage that could develop to dementia. We performed Mini-Mental State Examination (MMSE), ambulatory BP monitoring (ABPM), echocardiography, and blood tests in 444 HF patients just before leaving hospitals. Mild CI, a measure of cognitive function, was defined as the score <26. The mean age of the patients was 68±13 years; 61.5% were male; 22.5% were riser pattern. The MMSE score was significantly lower in the Riser group than in the Non-dipper and Dipper group (23±4 vs. 25±5, 26±4, respectively, P < 0.01). In multivariable logistic regression analysis, a riser pattern was significantly associated with mild CI (odds ratio 2.38, 95% confidence intervals 1.29-4.42, P < 0.01) after adjusting for significant covariates. The riser pattern was associated with mild CI in HF patients. An abnormal circadian BP rhythm in HF patients is clinically significant as a potential indicator of subclinical brain damage. © American Journal of Hypertension, Ltd 2015. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Packaged FBG sensors for real-time stress monitoring on deep-water riser

    NASA Astrophysics Data System (ADS)

    Xu, Jian; Yang, Dexing; Jiang, Yajun; Wang, Meirong; Zhai, Huailun; Bai, Yang

    2014-11-01

    The safety of under-water risers in drilling platform is of great significance. A packaged fiber Bragg grating (FBG) sensor for real-time stress monitoring is designed for the applications on oil drilling risers under 3000 meters deep water. A copper tube which is the main component of the sensor has a small hole along its axes and a groove at its each end. The bare FBG is passed through the small hole and fixed to its ends by epoxy resin. Then the copper tube is packaged by filling the groove with structural adhesive. In order to avoid that the outer water-pressure is applied on the epoxy resin through the structural adhesive, a gap between the two types of glues is left. The relationships between the stress of the riser and the tension, pressure, temperature of the single sensor are discussed, respectively. The measured tension sensitivity is 136.75 pm/KN while the minimum R-square value is 0.99997. The experimental results also show that there is a good linear response between water-pressure and the Bragg wavelength from 0 to 30MPa, and the sensor can even survive under the pressure more than 30MPa. In addition, the Bragg wavelength shifts linearly with the increasing temperature from 0 to 40°C. So, the pressure and temperature can be easily compensated if another sensor without tension is used.

  2. The effect of riser end geometry on gas-solid hydrodynamics in a CFB riser operating in the core annular and dilute homogeneous flow regimes

    DOE PAGES

    Breault, Ronald W.; Monazam, Esmail R.; Shadle, Lawrence J.; ...

    2017-02-12

    Riser hydrodynamics are a function of the flow rates of gas and solids as well as the exit geometry, particularly when operated above the upper transport velocity. This work compares the exit voidage for multiple geometries and two different solids: Geldart group A glass beads and Geldart group B coke. Geometries were changed by modifying the volume of an abrupt T-shaped exit above the lateral riser exit. This was accomplished by positioning a plunger at various heights above the exit from zero to 0.38 m. A dimensionless expression used to predict smooth exit voidage was modified to account for themore » effect of the depth of the blind-T. The new correlation contains the solids-gas load ratio, solids-to-gas density ratio, bed-to-particle diameter ratio, gas Reynolds Number, as well as a term for the exit geometry. This study also found that there was a minimum riser roof height above the blind-T exit beyond which the riser exit voidage was not affected by the exit geometry. A correlation for this minimum riser roof height has also been developed in this study. This study covered riser superficial gas velocities of 4.35 to 7.7 m/s and solids circulation rates of 1.3 to 11.5 kg/s.« less

  3. 29 CFR 1926.1052 - Stairways.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...° from horizontal. (3) Riser height and tread depth shall be uniform within each flight of stairs, including any foundation structure used as one or more treads of the stairs. Variations in riser height or... having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped...

  4. 29 CFR 1926.1052 - Stairways.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...° from horizontal. (3) Riser height and tread depth shall be uniform within each flight of stairs, including any foundation structure used as one or more treads of the stairs. Variations in riser height or... having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped...

  5. 29 CFR 1926.1052 - Stairways.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...° from horizontal. (3) Riser height and tread depth shall be uniform within each flight of stairs, including any foundation structure used as one or more treads of the stairs. Variations in riser height or... having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped...

  6. 29 CFR 1926.1052 - Stairways.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...° from horizontal. (3) Riser height and tread depth shall be uniform within each flight of stairs, including any foundation structure used as one or more treads of the stairs. Variations in riser height or... having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped...

  7. 29 CFR 1926.1052 - Stairways.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...° from horizontal. (3) Riser height and tread depth shall be uniform within each flight of stairs, including any foundation structure used as one or more treads of the stairs. Variations in riser height or... having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped...

  8. Bed inventory overturn in a circulating fluid bed riser with pant-leg structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jinjing Li; Wei Wang; Hairui Yang

    2009-05-15

    The special phenomenon, nominated as bed inventory overturn, in circulating fluid bed (CFB) riser with pant-leg structure was studied with model calculation and experimental work. A compounded pressure drop mathematic model was developed and validated with the experimental data in a cold experimental test rig. The model calculation results agree well with the measured data. In addition, the intensity of bed inventory overturn is directly proportional to the fluidizing velocity and is inversely proportional to the branch point height. The results in the present study provide significant information for the design and operation of a CFB boiler with pant-leg structure.more » 15 refs., 10 figs., 1 tab.« less

  9. 46 CFR 116.438 - Stairtowers, stairways, ladders, and elevators.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... landings of all stairways shall be composed of steel, and risers must be of approved incombustible material... of riser of stairs in different flights of stairs in a stairway or stairtower must be minimized. In... riser shall not have a variance exceeding 5 millimeters (0.19685 inches). (h) In a stairway or...

  10. 30 CFR 250.516 - Blowout preventer system tests, inspections, and maintenance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... inspection, whichever is longer. (2) You must visually inspect your BOP system and marine riser at least once.... The District Manager may approve alternate methods and frequencies to inspect a marine riser. (h) BOP... drills, and inspections of the BOP system, system components, and marine riser in the driller's report...

  11. 46 CFR 116.438 - Stairtowers, stairways, ladders, and elevators.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... landings of all stairways shall be composed of steel, and risers must be of approved incombustible material... of riser of stairs in different flights of stairs in a stairway or stairtower must be minimized. In... riser shall not have a variance exceeding 5 millimeters (0.19685 inches). (h) In a stairway or...

  12. 30 CFR 250.517 - Blowout preventer system tests, inspections, and maintenance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... on a daily basis. You must visually inspect your subsea BOP system and marine riser at least once... equipment. The BSEE District Manager may approve alternate methods and frequencies to inspect a marine riser..., actuations, crew drills, and inspections of the BOP system, system components, and marine riser in the...

  13. 30 CFR 250.517 - Blowout preventer system tests, inspections, and maintenance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... on a daily basis. You must visually inspect your subsea BOP system and marine riser at least once... equipment. The BSEE District Manager may approve alternate methods and frequencies to inspect a marine riser..., actuations, crew drills, and inspections of the BOP system, system components, and marine riser in the...

  14. 46 CFR 116.438 - Stairtowers, stairways, ladders, and elevators.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... landings of all stairways shall be composed of steel, and risers must be of approved incombustible material... of riser of stairs in different flights of stairs in a stairway or stairtower must be minimized. In... riser shall not have a variance exceeding 5 millimeters (0.19685 inches). (h) In a stairway or...

  15. 46 CFR 116.438 - Stairtowers, stairways, ladders, and elevators.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... landings of all stairways shall be composed of steel, and risers must be of approved incombustible material... of riser of stairs in different flights of stairs in a stairway or stairtower must be minimized. In... riser shall not have a variance exceeding 5 millimeters (0.19685 inches). (h) In a stairway or...

  16. 30 CFR 250.905 - How do I get approval for the installation, modification, or repair of my platform?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF...., cathodic protection systems; jacket design; pile foundations; drilling, production, and pipeline risers and... design or analysis of the platform. Examples of relevant data include information on waves, wind, current...

  17. Estimating the Size and Timing of Maximum Amplitude for Cycle 23 from Its Early Cycle Behavior

    NASA Technical Reports Server (NTRS)

    Wilson, Robert M.; Hathaway, David H.; Reichmann, Edwin J.

    1998-01-01

    On the basis of the lowest observed smoothed monthly mean sunspot number, cycle 23 appears to have conventionally begun in May 1996, in conjunction with the first appearance of a new cycle, high-latitude spot-group. Such behavior, however, is considered rather unusual, since, previously (based upon the data- available cycles 12-22), the first appearance of a new cycle, high-latitude spot- group has always preceded conventional onset by at least 3 months. Furthermore, accepting May 1996 as the official start for cycle 23 poses a dilemma regarding its projected size and timing of maximum amplitude. Specifically, from the max-min and amplitude-period relationships we infer that cycle 23 should be above average in size and a fast riser, with maximum amplitude occurring before May 2000 (being in agreement with projections for cycle 23 based on precursor information), yet from its initial languid rate of rise (during the first 6 months of the cycle) we infer that it should be below average in size and a slow riser, with maximum amplitude occurring after May 2000. The dilemma vanishes, however, when we use a slightly later-occurring onset. For example, using August 1996, a date associated with a local secondary minimum prior to the rapid rise that began shortly thereafter (in early 1997), we infer that cycle 23's rate of rise is above that for the mean of cycles 1-22, the mean of cycles 10-22 (the modern era cycles), the mean of the modern era'fast risers,' and the largest of the modern era 'slow risers' (i.e., cycle 20), thereby, suggesting that cycle 23 will be both fast-rising and above average in size, peaking before August 2000. Additionally, presuming cycle 23 to be a well- behaved fast-rising cycle (regardless of whichever onset date is used), we also infer that its maximum amplitude likely will measure about 144.0 q+/- 28.8 (from the general behavior found for the bulk of modern era fast risers; i.e., 5 of 7 have had their maximum amplitude to lie within 20% of the mean curve for modern era fast risers). It is apparent, then, that sunspot number growth during 1998 will prove crucial for correctly establishing the size and shape of cycle 23.

  18. 46 CFR 72.05-20 - Stairways, ladders, and elevators.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... landings of all Types 1, 2, and 3 stairways shall be of solid steel construction. Risers shall be of... width of the stairs, the depth of the tread, or the height of the risers in any flight. Where variation in height of riser or depth of tread in different flights is necessary, such variations shall be...

  19. 29 CFR 1917.120 - Fixed stairways.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... be positioned within the range of 30 degrees to 50 degrees to the horizontal with uniform riser.... Riser height shall be from 6 to 7.5 inches (15.24 to 19.05 cm), stair width a minimum of 22 inches (55... stairs having four or more risers shall have stair railings or handrails complying with § 1917.112(c)(1...

  20. 46 CFR 72.05-20 - Stairways, ladders, and elevators.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... landings of all Types 1, 2, and 3 stairways shall be of solid steel construction. Risers shall be of... width of the stairs, the depth of the tread, or the height of the risers in any flight. Where variation in height of riser or depth of tread in different flights is necessary, such variations shall be...

  1. 29 CFR 1917.120 - Fixed stairways.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... be positioned within the range of 30 degrees to 50 degrees to the horizontal with uniform riser.... Riser height shall be from 6 to 7.5 inches (15.24 to 19.05 cm), stair width a minimum of 22 inches (55... stairs having four or more risers shall have stair railings or handrails complying with § 1917.112(c)(1...

  2. 46 CFR 72.05-20 - Stairways, ladders, and elevators.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... landings of all Types 1, 2, and 3 stairways shall be of solid steel construction. Risers shall be of... width of the stairs, the depth of the tread, or the height of the risers in any flight. Where variation in height of riser or depth of tread in different flights is necessary, such variations shall be...

  3. 29 CFR 1917.120 - Fixed stairways.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... be positioned within the range of 30 degrees to 50 degrees to the horizontal with uniform riser.... Riser height shall be from 6 to 7.5 inches (15.24 to 19.05 cm), stair width a minimum of 22 inches (55... stairs having four or more risers shall have stair railings or handrails complying with § 1917.112(c)(1...

  4. 29 CFR 1917.120 - Fixed stairways.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... be positioned within the range of 30 degrees to 50 degrees to the horizontal with uniform riser.... Riser height shall be from 6 to 7.5 inches (15.24 to 19.05 cm), stair width a minimum of 22 inches (55... stairs having four or more risers shall have stair railings or handrails complying with § 1917.112(c)(1...

  5. 30 CFR 250.516 - Blowout preventer system tests, inspections, and maintenance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... marine riser at least once each day if weather and sea conditions permit. You may use television cameras... inspect a marine riser. (h) BOP maintenance. You must maintain your BOP system to ensure that the... components, and marine riser in the driller's report. In addition, you must: (1) Record BOP test pressures on...

  6. Crystal accumulation in the Hanford Waste Treatment Plant high level waste melter: Summary of FY2016 experiements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, K.; Fowley, M.; Miller, D.

    2016-12-01

    Five experiments were completed with the full-scale, room temperature Hanford Waste Treatment and Immobilization Plant (WTP) high-level waste (HLW) melter riser test system to observe particle flow and settling in support of a crystal tolerant approach to melter operation. A prototypic pour rate was maintained based on the volumetric flow rate. Accumulation of particles was observed at the bottom of the riser and along the bottom of the throat after each experiment. Measurements of the accumulated layer thicknesses showed that the settled particles at the bottom of the riser did not vary in thickness during pouring cycles or idle periods.more » Some of the settled particles at the bottom of the throat were re-suspended during subsequent pouring cycles, and settled back to approximately the same thickness after each idle period. The cause of the consistency of the accumulated layer thicknesses is not year clear, but was hypothesized to be related to particle flow back to the feed tank. Additional experiments reinforced the observation of particle flow along a considerable portion of the throat during idle periods. Limitations of the system are noted in this report and may be addressed via future modifications. Follow-on experiments will be designed to evaluate the impact of pouring rate on particle re-suspension, the influence of feed tank agitation on particle accumulation, and the effect of changes in air lance positioning on the accumulation and re-suspension of particles at the bottom of the riser. A method for sampling the accumulated particles will be developed to support particle size distribution analyses. Thicker accumulated layers will be intentionally formed via direct addition of particles to select areas of the system to better understand the ability to continue pouring and re-suspend particles. Results from the room temperature system will be correlated with observations and data from the Research Scale Melter (RSM) at Pacific Northwest National Laboratory, and coordinated with modeling efforts underway at Idaho National Laboratory.« less

  7. 29 CFR 1910.23 - Guarding floor and wall openings and holes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Stairway railings and guards. (1) Every flight of stairs having four or more risers shall be equipped with... than 30 inches from upper surface of top rail to surface of tread in line with face of riser at forward... face of riser or to surface of ramp. (iii) The size of handrails shall be: When of hardwood, at least 2...

  8. 29 CFR 1910.23 - Guarding floor and wall openings and holes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Stairway railings and guards. (1) Every flight of stairs having four or more risers shall be equipped with... than 30 inches from upper surface of top rail to surface of tread in line with face of riser at forward... face of riser or to surface of ramp. (iii) The size of handrails shall be: When of hardwood, at least 2...

  9. 29 CFR 1910.23 - Guarding floor and wall openings and holes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Stairway railings and guards. (1) Every flight of stairs having four or more risers shall be equipped with... than 30 inches from upper surface of top rail to surface of tread in line with face of riser at forward... face of riser or to surface of ramp. (iii) The size of handrails shall be: When of hardwood, at least 2...

  10. 29 CFR 1910.23 - Guarding floor and wall openings and holes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Stairway railings and guards. (1) Every flight of stairs having four or more risers shall be equipped with... than 30 inches from upper surface of top rail to surface of tread in line with face of riser at forward... face of riser or to surface of ramp. (iii) The size of handrails shall be: When of hardwood, at least 2...

  11. The relationship between a blunted morning surge and a reversed nocturnal blood pressure dipping or "riser" pattern.

    PubMed

    Fujiwara, Takeshi; Tomitani, Naoko; Sato, Keiko; Okura, Ayako; Suzuki, Noriyuki; Kario, Kazuomi

    2017-11-01

    The authors sought to determine the association between the blunted morning blood pressure (BP) surge and nocturnal BP dipping of the "riser" pattern in 501 patients with hypertension enrolled in the ACHIEVE-ONE (Ambulatory Blood Pressure Control and Home Blood Pressure [Morning and Evening] Lowering by the N-Channel Blocker Cilnidipine) trial. The patients' sleep-trough morning BP surge and prewaking surge were calculated and then classified according to their nocturnal systolic BP reduction pattern as extreme dippers, dippers, nondippers, and risers. The prevalence of the riser pattern was significantly higher in both the lowest sleep-trough morning BP surge decile and the prewaking surge decile (blunted surge group) compared with the remaining deciles (56.0% vs 10.4% [P<.0001] and 59.2% vs 10.2% [P<.0001], respectively). The riser pattern was a significant determinant of both blunted sleep-trough morning BP surge (odds ratio, 73.3; P<.0001) and blunted prewaking surge (odds ratio, 14.8; P<.0001). The high prevalence of the riser pattern in patients with blunted morning BP surges may account for the cardiovascular risk previously reported in such patients. ©2017 Wiley Periodicals, Inc.

  12. MP-Pic simulation of CFB riser with EMMS-based drag model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, F.; Song, F.; Benyahia, S.

    2012-01-01

    MP-PIC (multi-phase particle in cell) method combined with the EMMS (energy minimization multi- scale) drag force model was implemented with the open source program MFIX to simulate the gas–solid flows in CFB (circulatingfluidizedbed) risers. Calculated solid flux by the EMMS drag agrees well with the experimental value; while the traditional homogeneous drag over-predicts this value. EMMS drag force model can also predict the macro-and meso-scale structures. Quantitative comparison of the results by the EMMS drag force model and the experimental measurements show high accuracy of the model. The effects of the number of particles per parcel and wall conditions onmore » the simulation results have also been investigated in the paper. This work proved that MP-PIC combined with the EMMS drag model can successfully simulate the fluidized flows in CFB risers and it serves as a candidate to realize real-time simulation of industrial processes in the future.« less

  13. Statistical analysis on the signals monitoring multiphase flow patterns in pipeline-riser system

    NASA Astrophysics Data System (ADS)

    Ye, Jing; Guo, Liejin

    2013-07-01

    The signals monitoring petroleum transmission pipeline in offshore oil industry usually contain abundant information about the multiphase flow on flow assurance which includes the avoidance of most undesirable flow pattern. Therefore, extracting reliable features form these signals to analyze is an alternative way to examine the potential risks to oil platform. This paper is focused on characterizing multiphase flow patterns in pipeline-riser system that is often appeared in offshore oil industry and finding an objective criterion to describe the transition of flow patterns. Statistical analysis on pressure signal at the riser top is proposed, instead of normal prediction method based on inlet and outlet flow conditions which could not be easily determined during most situations. Besides, machine learning method (least square supported vector machine) is also performed to classify automatically the different flow patterns. The experiment results from a small-scale loop show that the proposed method is effective for analyzing the multiphase flow pattern.

  14. Towards a census of high-redshift dusty galaxies with Herschel. A selection of "500 μm-risers"

    NASA Astrophysics Data System (ADS)

    Donevski, D.; Buat, V.; Boone, F.; Pappalardo, C.; Bethermin, M.; Schreiber, C.; Mazyed, F.; Alvarez-Marquez, J.; Duivenvoorden, S.

    2018-06-01

    Context. Over the last decade a large number of dusty star-forming galaxies has been discovered up to redshift z = 2 - 3 and recent studies have attempted to push the highly confused Herschel SPIRE surveys beyond that distance. To search for z ≥ 4 galaxies they often consider the sources with fluxes rising from 250 μm to 500 μm (so-called "500 μm-risers"). Herschel surveys offer a unique opportunity to efficiently select a large number of these rare objects, and thus gain insight into the prodigious star-forming activity that takes place in the very distant Universe. Aims: We aim to implement a novel method to obtain a statistical sample of 500 μm-risers and fully evaluate our selection inspecting different models of galaxy evolution. Methods: We consider one of the largest and deepest Herschel surveys, the Herschel Virgo Cluster Survey. We develop a novel selection algorithm which links the source extraction and spectral energy distribution fitting. To fully quantify selection biases we make end-to-end simulations including clustering and lensing. Results: We select 133 500 μm-risers over 55 deg2, imposing the criteria: S500 > S350 > S250, S250 > 13.2 mJy and S500 > 30 mJy. Differential number counts are in fairly good agreement with models, displaying a better match than other existing samples. The estimated fraction of strongly lensed sources is 24+6-5% based on models. Conclusions: We present the faintest sample of 500 μm-risers down to S250 = 13.2 mJy. We show that noise and strong lensing have an important impact on measured counts and redshift distribution of selected sources. We estimate the flux-corrected star formation rate density at 4 < z < 5 with the 500 μm-risers and find it to be close to the total value measured in far-infrared. This indicates that colour selection is not a limiting effect to search for the most massive, dusty z > 4 sources.

  15. The small community solar thermal power experiment. Parabolic dish technology for industrial process heat application

    NASA Technical Reports Server (NTRS)

    Polzien, R. E.; Rodriguez, D.

    1981-01-01

    Aspects of incorporating a thermal energy transport system (ETS) into a field of parabolic dish collectors for industrial process heat (IPH) applications were investigated. Specific objectives are to: (1) verify the mathematical optimization of pipe diameters and insulation thicknesses calculated by a computer code; (2) verify the cost model for pipe network costs using conventional pipe network construction; (3) develop a design and the associated production costs for incorporating risers and downcomers on a low cost concentrator (LCC); (4) investigate the cost reduction of using unconventional pipe construction technology. The pipe network design and costs for a particular IPH application, specifically solar thermally enhanced oil recovery (STEOR) are analyzed. The application involves the hybrid operation of a solar powered steam generator in conjunction with a steam generator using fossil fuels to generate STEOR steam for wells. It is concluded that the STEOR application provides a baseline pipe network geometry used for optimization studies of pipe diameter and insulation thickness, and for development of comparative cost data, and operating parameters for the design of riser/downcomer modifications to the low cost concentrator.

  16. Installation Restoration Program. Phase II. Confirmation/Quantification Stage 2 for Griffiss Air Force Base, New York.

    DTIC Science & Technology

    1985-02-20

    Surface Cemennt/entonte Grout Rat 20/1 6" Diameter Bore "Ole 8 Foit B.G.S. Bentorito 4" Diameter POes" Schedle 409 Fee S.O.S.PVC Riser Pipe with...Casing with Locking Cap GRiser Pipe StickupGround Surface 2.2Fe Cement/BSentonite Grout Ratio 20/1 8" Diameter Bore Hole cv Ile- 3 Feet B.G.S...Ground Surface 4’. Ground Surface .0~ Cemtert/Bentonlte Grout Rat 20/1 8" Diamneter Bore Hole__ 4" Diameter Pl O Schedule 404 PVC Riser Pipe FetBGS

  17. Design and Application of Novel Horizontal Circulating Fluidized Bed Boiler

    NASA Astrophysics Data System (ADS)

    Lit, Q. H.; Zhang, Y. G.; Meng, A. H.

    The vertical circulating fluidized bed (CFB) boiler has been found wide application in power generation and tends to be enlarged in capacity. Because CFB is one of environment friendly and high efficiency combustion technologies, the CFB boiler has also been expected to be used in the industrial area, such as textile mill, region heating, brewery, seed drying and so on. However, the necessary height of furnace is hard to be implemented for CFB with especially small capacity. Thereby, a novel horizontal circulating fluidized bed boiler has been proposed and developed. The horizontal CFB is composed of primary combustion chamber, secondary combustion chamber, burnout chamber, cyclone, loop seal, heat recovery area. The primary combustion chamber is a riser like as that in vertical CFB, and the secondary combustion chamber is a downward passage that is a natural extension of the primary riser, which can reduce the overall height of the boiler. In some extent, the burnout chamber is also the extension of primary riser. The capacity of horizontal CFB is about 4.2-24.5MWth (6-35t/h) steam output or equivalent hot water supply. The hot water boiler of 7MWth and steam boilers of 4.2MWth (6t/h) and 10.5MWth (15t/h) are all designed and working well now. The three units of hot water horizontal CFB boiler were erected in the Neimenggu Autonomous Region, Huhehaote city for region heating. The three units of steam horizontal CFB has been installed in Yunnan, Jiang Xi and Guangdong provinces, respectively. The basic principle for horizontal CFB and experiences for designing and operating are presented in this paper. Some discussions are also given to demonstrate the promising future of horizontal CFB.

  18. Two cases of malignant hypertension with reversible diffuse leukoencephalopathy exhibiting a reversible nocturnal blood pressure "riser" pattern.

    PubMed

    Eguchi, Kazuo; Kasahara, Kentaro; Nagashima, Akinori; Mor, Tadashi; Nii, Takanobu; Ibaraki, Kazuo; Kario, Kazuomi; Shimada, Kazuyuki

    2002-05-01

    We report two cases of malignant hypertension with reversible diffuse leukoencephalopathy demonstrating a nocturnal blood pressure (BP) rising pattern ("riser" pattern). Case 1 was a 54-year-old man diagnosed with malignant hypertension who presented with diffuse leukoencephalopathy and nocturnal BP rise during the acute phase. These abnormal findings diminished after treatment of hypertension. Case 2 was a 50-year-old woman diagnosed with malignant hypertension in association with leukoencephalopathy, heart failure and acute renal failure. She also presented with a "riser" pattern during the acute phase. In contrast to case 1, the leukoencephalopathy and "riser" pattern in case 2 were not improved even after 1 month of treatment. Following intensive antihypertensive treatment, renal failure was improved in case 1, but renal failure was not improved after 1 month in case 2. In conclusion, a possible explanation of this phenomenon is that a causative volume overload due to renal dysfunction produced the temporal leukoencephalopathy-like brain edema and "riser" pattern in these cases.

  19. Helical wire stress analysis of unbonded flexible riser under irregular response

    NASA Astrophysics Data System (ADS)

    Wang, Kunpeng; Ji, Chunyan

    2017-06-01

    A helical wire is a critical component of an unbonded flexible riser prone to fatigue failure. The helical wire has been the focus of much research work in recent years because of the complex multilayer construction of the flexible riser. The present study establishes an analytical model for the axisymmetric and bending analyses of an unbonded flexible riser. The interlayer contact under axisymmetric loads in this model is modeled by setting radial dummy springs between adjacent layers. The contact pressure is constant during the bending response and applied to determine the slipping friction force per unit helical wire. The model tracks the axial stress around the angular position at each time step to calculate the axial force gradient, then compares the axial force gradient with the slipping friction force to judge the helical wire slipping region, which would be applied to determine the bending stiffness for the next time step. The proposed model is verified against the experimental data in the literature. The bending moment-curvature relationship under irregular response is also qualitatively discussed. The stress at the critical point of the helical wire is investigated based on the model by considering the local flexure. The results indicate that the present model can well simulate the bending stiffness variation during irregular response, which has significant effect on the stress of helical wire.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Breault, Ronald W.; Monazam, Esmail R.; Shadle, Lawrence J.

    Riser hydrodynamics are a function of the flow rates of gas and solids as well as the exit geometry, particularly when operated above the upper transport velocity. This work compares the exit voidage for multiple geometries and two different solids: Geldart group A glass beads and Geldart group B coke. Geometries were changed by modifying the volume of an abrupt T-shaped exit above the lateral riser exit. This was accomplished by positioning a plunger at various heights above the exit from zero to 0.38 m. A dimensionless expression used to predict smooth exit voidage was modified to account for themore » effect of the depth of the blind-T. The new correlation contains the solids-gas load ratio, solids-to-gas density ratio, bed-to-particle diameter ratio, gas Reynolds Number, as well as a term for the exit geometry. This study also found that there was a minimum riser roof height above the blind-T exit beyond which the riser exit voidage was not affected by the exit geometry. A correlation for this minimum riser roof height has also been developed in this study. This study covered riser superficial gas velocities of 4.35 to 7.7 m/s and solids circulation rates of 1.3 to 11.5 kg/s.« less

  1. Blind inlets: Conservation practices to reduce herbicide losses from closed depressional areas

    USDA-ARS?s Scientific Manuscript database

    Pesticides are designed to benefit agricultural production and may inadvertently affect water quality if environmental stewardship programs are not implemented. Closed depressional areas (potholes) are typical in the US Midwest and are usually drained with tile risers, however sediment and contamina...

  2. The simulation and experimental validation on gas-solid two phase flow in the riser of a dense fluidized bed

    NASA Astrophysics Data System (ADS)

    Wang, Xue-Yao; Jiang, Fan; Xu, Xiang; Wang, Sheng-Dian; Fan, Bao-Guo; Xiao, Yun-Han

    2009-06-01

    Gas-solid flow in dense CFB (circulating fluidized bed)) riser under the operating condition, superficial gas 15.5 m/s and solid flux 140 kg/m2s using Geldart B particles (sand) was investigated by experiments and CFD (computational fluid dynamics) simulation. The overall and local flow characteristics are determined using the axial pressure profiles and solid concentration profiles. The cold experimental results indicate that the axial solid concentration distribution contains a dilute region towards the up-middle zone and a dense region near the bottom and the top exit zones. The typical core-annulus structure and the back-mixing phenomenon near the wall of the riser can be observed. In addition, owing to the key role of the drag force of gas-solid phase, a revised drag force coefficient, based on the EMMS (energy-minimization multi-scale) model which can depict the heterogeneous character of gas-solid two phase flow, was proposed and coupled into the CFD control equations. In order to find an appropriate drag force model for the simulation of dense CFB riser, not only the revised drag force model but some other kinds of drag force model were used in the CFD. The flow structure, solid concentration, clusters phenomenon, fluctuation of two phases and axial pressure drop were analyzed. By comparing the experiment with the simulation, the results predicted by the EMMS drag model showed a better agreement with the experimental axial average pressure drop and apparent solid volume fraction, which proves that the revised drag force based on the EMMS model is an appropriate model for the dense CFB simulation.

  3. Off-axis silicon carbide substrates

    DOEpatents

    Edgar, James; Dudley, Michael; Kuball, Martin; Zhang, Yi; Wang, Guan; Chen, Hui; Zhang, Yu

    2014-09-02

    A method of epitaxial growth of a material on a crystalline substrate includes selecting a substrate having a crystal plane that includes a plurality of terraces with step risers that join adjacent terraces. Each terrace of the plurality or terraces presents a lattice constant that substantially matches a lattice constant of the material, and each step riser presents a step height and offset that is consistent with portions of the material nucleating on adjacent terraces being in substantial crystalline match at the step riser. The method also includes preparing a substrate by exposing the crystal plane; and epitaxially growing the material on the substrate such that the portions of the material nucleating on adjacent terraces merge into a single crystal lattice without defects at the step risers.

  4. Apparatus for hot-gas desulfurization of fuel gases

    DOEpatents

    Bissett, Larry A.

    1992-01-01

    An apparatus for removing sulfur values from a hot fuel gas stream in a fdized bed contactor containing particulate sorbent material by employing a riser tube regeneration arrangement. Sulfur-laden sorbent is continuously removed from the fluidized bed through a stand pipe to the riser tube and is rapidly regenerated in the riser tube during transport of the sorbent therethrough by employing an oxygen-containing sorbent regenerating gas stream. The riser tube extends from a location below the fluidized bed to an elevation above the fluidized bed where a gas-solid separating mechanism is utilized to separate the regenerated particulate sorbent from the regeneration gases and reaction gases so that the regenerated sorbent can be returned to the fluidized bed for reuse.

  5. Using Pneumatics to Perform Laboratory Hydraulic Conductivity Tests on Gravel with Underdamped Responses

    NASA Astrophysics Data System (ADS)

    Judge, A. I.

    2011-12-01

    A permeameter has been designed and built to perform laboratory hydraulic conductivity tests on various kinds of gravel samples with hydraulic conductivity values ranging from 0.1 to 1 m/s. The tests are commenced by applying 200 Pa of pneumatic pressure to the free surface of the water column in a riser connected above a cylinder that holds large gravel specimens. This setup forms a permeameter specially designed for these tests which is placed in a barrel filled with water, which acts as a reservoir. The applied pressure depresses the free surface in the riser 2 cm until it is instantly released by opening a ball valve. The water then flows through the base of the cylinder and the specimen like a falling head test, but the water level oscillates about the static value. The water pressure and the applied air pressure in the riser are measured with vented pressure transducers at 100 Hz. The change in diameter lowers the damping frequency of the fluctuations of the water level in the riser, which allows for underdamped responses to be observed for all tests. The results of tests without this diameter change would otherwise be a series of critically damped responses with only one or two oscillations that dampen within seconds and cannot be evaluated with equations for the falling head test. The underdamped responses oscillate about the static value at about 1 Hz and are very sensitive to the hydraulic conductivity of all the soils tested. These fluctuations are also very sensitive to the inertia and friction in the permeameter that are calculated considering the geometry of the permeameter and verified experimentally. Several gravel specimens of various shapes and sizes are tested that show distinct differences in water level fluctuations. The friction of the system is determined by calibrating the model with the results of tests performed where the cylinder had no soil in it. The calculation of the inertia in the response of the water column for the typical testing setup was also verified by performing tests without soil. The friction coefficient of the cylinder base below the specimen where the water enters and exits throughout the test has a minor loss which is determined by analyzing these results. The hydraulic conductivity is then calculated by calculating the friction of the system and subtracting the friction loss from the frictional component of the damping frequency calibrated to the measured data for each test. This allows for a very precise and accurate calculation of the hydraulic conductivity of the soil tested because the closed form analytical model developed and used considers the underdamped responses which fit to the measured data unique to every test more easily than any other method. The average error in predicting the head values for preliminary results is 1 mm, or about 4% of the initial displacement for all tests.

  6. New roles of LWD and wireline logging in scientific ocean drilling

    NASA Astrophysics Data System (ADS)

    Sanada, Y.; Kido, Y. N.; Moe, K.; Aoike, K.

    2014-12-01

    D/V Chikyu implemented by CDEX/JAMSTEC joined IODP from 2007. Various LWD (Logging While Drilling) and wireline logging have been carried out in many expeditions and for various purposes. Significant features of logging in Chikyu expeditions are many use of LWD than wireline logging, and riser dirlling. riser selected specific tools for each scientific target, and 3) carried out various borehole experiments. LWD has been more popular than wireline logging in Chikyu expeditions, because its advantages match theirs science targets. The advantages are followings. 1) LWD has more opportunities for measurement in unstable borehole, such as in the series of Nankai trough drilling expeditions. 2) LWD realtime data allows us to make realtime interpretation and operational decision. Realtime interpretation was required to set obsevartory at the properposition. 3) LWD before coring allows us to make a strategy of spot coring.We can design coring intervals for our interest and core length to improve core recovery.Riser drilling brings us merits for logging. One is hole stability (good hole condition) and the other is the use of large diameter tools. Controled drilling mud in riser drilling system prevent mud invasion to formation and mitigates collapse of borehole wall. They reduce the risk of tool stack and improve data quality. Large diameter of riser pipe enhances variation of tool seizes. A couple of new tools were used for new measurement and improvement of the data quality. For example, SonicScanner (trademark of Schulumberger) successfully measured compressional and share velocity in very low velocities at the soft sediment, where it has been difficult to measure them with conventional DSI tool (Exp319). The stress and pore pressure in the borehole were measured with the wireline logging tool, (Schlumberger MDT). The single probe tool enable to measure temporal formation fluid pressure. The double packer tool enable to fracture test by sealing and pumping in the borehole. These in-situ measurement and stress experiment data are very important to understand physical properties and mechanism of fault zone (Exp319).Those new technologies and tools also expand the envelope of scientific ocean drilling.

  7. Phosphorus losses from drainage systems: breaking the surface tile riser connection

    USDA-ARS?s Scientific Manuscript database

    In freshwater ecosystems, phosphorus is generally the nutrient most limiting algal growth. Agricultural drainage systems in the upper Midwestern US are generally designed to drain water as quickly as possible, in order to ensure trafficability and minimize crop damage due to flooding. An unintended ...

  8. Model validation using CFD-grade experimental database for NGNP Reactor Cavity Cooling Systems with water and air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Manera, Annalisa; Corradini, Michael; Petrov, Victor

    This project has been focused on the experimental and numerical investigations of the water-cooled and air-cooled Reactor Cavity Cooling System (RCCS) designs. At this aim, we have leveraged an existing experimental facility at the University of Wisconsin-Madison (UW), and we have designed and built a separate effect test facility at the University of Michigan. The experimental facility at UW has underwent several upgrades, including the installation of advanced instrumentation (i.e. wire-mesh sensors) built at the University of Michigan. These provides highresolution time-resolved measurements of the void-fraction distribution in the risers of the water-cooled RCCS facility. A phenomenological model has beenmore » developed to assess the water cooled RCCS system stability and determine the root cause behind the oscillatory behavior that occurs under normal two-phase operation. Testing under various perturbations to the water-cooled RCCS facility have resulted in changes in the stability of the integral system. In particular, the effects on stability of inlet orifices, water tank volume have and system pressure been investigated. MELCOR was used as a predictive tool when performing inlet orificing tests and was able to capture the Density Wave Oscillations (DWOs) that occurred upon reaching saturation in the risers. The experimental and numerical results have then been used to provide RCCS design recommendations. The experimental facility built at the University of Michigan was aimed at the investigation of mixing in the upper plenum of the air-cooled RCCS design. The facility has been equipped with state-of-theart high-resolution instrumentation to achieve so-called CFD grade experiments, that can be used for the validation of Computational Fluid Dynanmics (CFD) models, both RANS (Reynold-Averaged) and LES (Large Eddy Simulations). The effect of risers penetration in the upper plenum has been investigated as well.« less

  9. Upper Ocean Measurements of Water Masses and Circulation in the Japan Sea

    DTIC Science & Technology

    2003-09-30

    Japan Sea via Tsugaru Strait into the N. Pacific and through Soya Strait into the Okhotsk Sea. On float entered the Okhotsk Sea through Soya Strait and...Riser (2003) Connections between the Japan Sea and Okhotsk Sea through Soya Strait. Submitted to Journal of Geophysical Research. Riser, S., M...PUBLICATIONS Danchenkov, M. and S. Riser (2003) Connections between the Japan Sea and Okhotsk Sea through Soya Strait. Submitted to Journal of Geophysical

  10. Numerical Simulation of the Vortex-Induced Vibration of A Curved Flexible Riser in Shear Flow

    NASA Astrophysics Data System (ADS)

    Zhu, Hong-jun; Lin, Peng-zhi

    2018-06-01

    A series of fully three-dimensional (3D) numerical simulations of flow past a free-to-oscillate curved flexible riser in shear flow were conducted at Reynolds number of 185-1015. The numerical results obtained by the two-way fluid-structure interaction (FSI) simulations are in good agreement with the experimental results reported in the earlier study. It is further found that the frequency transition is out of phase not only in the inline (IL) and crossflow (CF) directions but also along the span direction. The mode competition leads to the non-zero nodes of the rootmean- square (RMS) amplitude and the relatively chaotic trajectories. The fluid-structure interaction is to some extent reflected by the transverse velocity of the ambient fluid, which reaches the maximum value when the riser reaches the equilibrium position. Moreover, the local maximum transverse velocities occur at the peak CF amplitudes, and the values are relatively large when the vibration is in the resonance regions. The 3D vortex columns are shed nearly parallel to the axis of the curved flexible riser. As the local Reynolds number increases from 0 at the bottom of the riser to the maximum value at the top, the wake undergoes a transition from a two-dimensional structure to a 3D one. More irregular small-scale vortices appeared at the wake region of the riser, undergoing large amplitude responses.

  11. Riser Pattern: Another Determinant of Heart Failure With Preserved Ejection Fraction.

    PubMed

    Komori, Takahiro; Eguchi, Kazuo; Saito, Toshinobu; Hoshide, Satoshi; Kario, Kazuomi

    2016-10-01

    Paradoxical increase in blood pressure (BP) during sleep, exceeding those of awake BP, is called the "riser" BP pattern, and known as an abnormal circadian BP rhythm, has been reported to be associated with adverse cardiovascular prognoses. However, the significance of ambulatory BP in heart failure patients with preserved ejection fraction (HFpEF) has never been reported. Here, we tested our hypothesis that abnormal circadian BP rhythm is associated with HFpEF. The authors enrolled 508 patients with hospitalized HF (age 68±13 years; 315 men, 193 women). There were 232 cases of HFpEF and 276 cases of heart failure with reduced ejection fraction (HFrEF). The riser BP pattern was significantly more frequent in the HFpEF (28.9%) group compared with the HFrEF group (19.9%). In a multivariable logistic regression analysis, the riser BP pattern was associated with HFpEF (odds ratio, 1.73; 95% confidence interval, 1.02-2.91; P=.041) independent of the other covariates. In conclusion, the riser BP pattern was associated with HFpEF. ©2016 Wiley Periodicals, Inc.

  12. Echo State Networks for data-driven downhole pressure estimation in gas-lift oil wells.

    PubMed

    Antonelo, Eric A; Camponogara, Eduardo; Foss, Bjarne

    2017-01-01

    Process measurements are of vital importance for monitoring and control of industrial plants. When we consider offshore oil production platforms, wells that require gas-lift technology to yield oil production from low pressure oil reservoirs can become unstable under some conditions. This undesirable phenomenon is usually called slugging flow, and can be identified by an oscillatory behavior of the downhole pressure measurement. Given the importance of this measurement and the unreliability of the related sensor, this work aims at designing data-driven soft-sensors for downhole pressure estimation in two contexts: one for speeding up first-principle model simulation of a vertical riser model; and another for estimating the downhole pressure using real-world data from an oil well from Petrobras based only on topside platform measurements. Both tasks are tackled by employing Echo State Networks (ESN) as an efficient technique for training Recurrent Neural Networks. We show that a single ESN is capable of robustly modeling both the slugging flow behavior and a steady state based only on a square wave input signal representing the production choke opening in the vertical riser. Besides, we compare the performance of a standard network to the performance of a multiple timescale hierarchical architecture in the second task and show that the latter architecture performs better in modeling both large irregular transients and more commonly occurring small oscillations. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. 30 CFR 291.101 - What definitions apply to this part?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... horizontal component or riser. Examples include anodes, valves, flanges, fittings, umbilicals, subsea... as a separate entity). Pipeline is the piping, risers, accessories and appurtenances installed for...

  14. Age-related differences in dynamic balance control during stair descent and effect of varying step geometry.

    PubMed

    Novak, A C; Komisar, V; Maki, B E; Fernie, G R

    2016-01-01

    The incidence of stairway falls and related injuries remains persistently high; however, the risk of stair injuries could be reduced through improved stairway design. The current study investigated dynamic balance control during stair descent and the effects of varying the step geometry. Data were collected from 20 healthy young and 20 older adults as they descended three staircases (riser heights of 7, 7.5 and 8 inches (178, 190 and 203 mm, respectively)). At each riser height, the tread run length was varied between 8 and 14 inches (203 mm and 356 mm) in one-inch (25 mm) increments. Kinematic data provided measures of segmental and whole-body dynamic control. Results demonstrated that older adults had greater lateral tilt of the upper body than young adults, but actually had larger margins of stability than the young in the antero-posterior direction as a result of their slower cadence. Nonetheless, for both age groups, the longer run lengths were found to provide the largest margins of stability. In addition, increase in run length and decrease in riser height tended to reduce forward upper body tilt. These results help to explain the underlying biomechanical factors associated with increased risk of falls and the relationship with step geometry. Considering the importance of stair ambulation in maintaining independence and activity in the community, this study highlights the definite need for safer stair design standards to minimize the risk of falls and increase stair safety across the lifespan. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  15. Effects of water-control structures on hydrologic and water-quality characteristics in selected agricultural drainage canals in eastern North Carolina

    USGS Publications Warehouse

    Treece, M.W.; Jaynes, M.L.

    1994-01-01

    November of water into and out of tidally affected canals in eastern North Carolina was documented before and after the installation of water-control structures. Water levels in five of the canals downstream from the water-control structures were controlled primarily by water-level fluctuations in estuarine receiving waters. Water-control structures also altered upstream water levels in all canals. Water levels were lowered upstream from tide gates, but increased upstream from flashboard risers. Both types of water-control structures attenuated the release of runoff following rainfall events, but in slightly different ways. Tide gates appeared to reduce peak discharge rates associated with rainfall, and flashboard risers lengthened the duration of runoff release. Tide gates had no apparent effect on pH, dissolved oxygen, suspended-sediment, or total phosphorus concentrations downstream from the structures. Specific conductance measured from composite samples collected with automatic samples increased downstream of tide gates after installation. Median concentrations of nitrite plus nitrate nitrogen were near the minimum detection level throughout the study; however, the number of observations of concentrations exceeding 0.1 milligram per liter dropped significantly after tide gates were installed. Following tide-gate installation, instantaneous loadings of nitrite plus nitrate nitrogen were significantly reduced at one test site, but this reduction was not observed at the other test site. Loadings of other nutrient species and suspended sediment did not change at the tide-gate test sites after tide-gate installation. Specific conductance was lower in the Beaufort County canals than in the Hyde County canals. Although there was a slight increase in median values at the flashboard-riser sites, the mean and maximum values declined substantially downstream from the risers following installation. This decline of specific conductance in the canals occurred despite a large increase of specific conductance in the tidal creek. Flashboard risers had no significant effect on concentrations of dissolved oxygen, suspended sediment, total ammonia plus organic nitrogen, or phosphorus. Maximum concentrations of ammonia nitrogen were smaller at both test sites after riser installation. In addition, concentrations of nitrite plus nitrate nitrogen exceeding 1.0 milligram per liter rarely occurred at the flashboard-riser test sites following installation of the risers. Median loadings of nitrite plus nitrate nitrogen and total nitrogen decreased at one riser test site following flashboard-riser installation. Tide gates and flashboard risers were associated with reductions in concentrations and export of nitrite plus nitrate nitrogen; however, these changes should be interpreted cautiously because reductions were not observed consistently at every site. The hydrology and baseline water-quality characteristics of the two study areas differ, making comparisons of the effectiveness of the two types of water-control structures difficult to interpret. The effects of water-control structures on the hydrology of the drainage canals are more meaningful than the changes in water quality. Tide gates and flashboard risers altered the hydrologic characteristics of the drainage canals and created an environment favorable for nutrient loss or transformation. Both structures retained agricultural drainage upstream, which increased potential storage for infiltration and reduced the potential for surface runoff, sediment, and nutrient transport, and higher peak outflow rates.

  16. Development and Testing of a Mobile Platform for Tank Remediation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nance, T.A.

    2001-01-16

    The Department of Energy (DOE) is committed to removing millions of gallons of high level radioactive waste from waste storage tanks at the Savannah River Site (SRS). SRS was the first site in the DOE complex to have emptied and closed high level waste tanks. Tank closure at the Site is now progressing to tanks containing waste composed of liquid and large deposits of solids, including a tank that has a potential ''heel''. A heel is a hardened mass of solid waste material spread across the tank bottom. Tank closure requires breaking up this heel and moving the material tomore » the intake of a pumping system for transfer from the tank. In the past, overhead spray systems have been used with some success at moving waste. But the limited number of risers restricts the coverage area of the overhead spray system. Therefore, a floor- level spray system will be used to separate manageable size chunks of the material from the heel. The chunks will be guided into the pump's intake to be remove from the tank. The floor-level spray system movement will be accomplished by using a mobile platform, a crawler, which provides transport to nearly every point on the tank floor. Transport of the spray system will allow the system to ''corral'' the waste away from the tank walls and control the movement of the material across the tank floor. Because the available access riser is small, and a wide crawler platform is required to support the spray system, the crawler's frame must fold to enter the tank. After entry into the tank, the crawler unfolds on the tank floor using the crawler drive tracks to expand the frame and position the mobile platform under the entry riser. The spray system will then be lowered separately through the entry riser and mated onto the crawler on the tank floor. The crawler and spray system are tethered and controlled remotely by personnel at the control station. Motorized cable reels will also be remotely controlled to pay out, retrieve, and manage the tethers as the mobile platform moves the spray system across the tank floor. Both the crawler and spray systems are designed to be retrievable. Development of the tank cleaning system was evaluated using a performance test program. The tests evaluated the spray system dynamics, the crawler's fit through the riser, the crawler landing in mocked up tank with simulant, the crawler's traction, and the crawler and spray system mating. Initial testing verified the crawler platform was compatible with the dynamics produced by the spray system. The riser fit test confirmed that a dedicated riser is required for deployment of the crawler and the spray system. The crawler traction test defined the capabilities of the crawler at different levels of simulant. Deployment testing through a mockup riser verified the basic system processes. Finally, testing of the complete system in a full-scale mockup with sludge simulant was performed to evaluate the tank cleaning ability of the crawler. This paper describes th e tank conditions, the tank closure process, the development of the crawler and spray system, and the testing program and results used to evaluate the mobile platform and spray system.« less

  17. 6. View of main interior staircase in foyer (partially freestanding ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. View of main interior staircase in foyer (partially free-standing and spiral, white pine), in foyer. Note: Back of riser with carved date "MCMXXXV" and "WE" (for Wharton Esherick, designer) - Curtis Bok House, 120 Upper Gulph Road, intersection of Route 320 & Route 76, Gulph Mills, Montgomery County, PA

  18. 30 CFR 291.101 - What definitions apply to this part?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... component or riser. Examples include anodes, valves, flanges, fittings, umbilicals, subsea manifolds...). Pipeline is the piping, risers, accessories and appurtenances installed for transportation of oil and gas...

  19. 30 CFR 291.101 - What definitions apply to this part?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... component or riser. Examples include anodes, valves, flanges, fittings, umbilicals, subsea manifolds...). Pipeline is the piping, risers, accessories and appurtenances installed for transportation of oil and gas...

  20. 30 CFR 291.101 - What definitions apply to this part?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... component or riser. Examples include anodes, valves, flanges, fittings, umbilicals, subsea manifolds...). Pipeline is the piping, risers, accessories and appurtenances installed for transportation of oil and gas...

  1. University students' notebook computer use: lessons learned using e-diaries to report musculoskeletal discomfort.

    PubMed

    Jacobs, K; Foley, G; Punnett, L; Hall, V; Gore, R; Brownson, E; Ansong, E; Markowitz, J; McKinnon, M; Steinberg, S; Ing, A; Wuest, Ellen; Dibiccari, Leah

    2011-02-01

    The objective of this pilot study was to identify if notebook accessories (ergonomic chair, desktop monitor and notebook riser) combined with a wireless keyboard, mouse and participatory ergonomics training would have the greatest impact on reducing self-reported upper extremity musculoskeletal discomfort in university students. In addition to pre-post computing and health surveys, the Ecological Momentary Assessment was used to capture change in discomfort over time using a personal digital assistant (PDA) as the e-diary. The PDA was programmed with a survey containing 45 questions. Four groups of university students were randomised to either intervention (three external computer accessories) or to control. Participants reported less discomfort with the ergonomic chair and notebook riser based on the pre-post survey data and the e-diary/PDA ANOVA analysis. However, the PDA data, adjusted for the effect of hours per day of computer use, showed no benefit of the chair and limited benefit from the riser. Statement of Relevance:University students' use of notebook computers has increased. This study found evidence of a positive effect of an adjustable chair or notebook riser when combined with ergonomic training on reducing discomfort. Daily notebook computer use of 4 h was confirmed as a risk factor. Without some form of ergonomic intervention, these students are likely to enter the workforce with poor computing habits, which places them on the road to future injuries as technology continues to play a dominant role in their lives.

  2. CHIMNEY FOR BOILING WATER REACTOR

    DOEpatents

    Petrick, M.

    1961-08-01

    A boiling-water reactor is described which has vertical fuel-containing channels for forming steam from water. Risers above the channels increase the head of water radially outward, whereby water is moved upward through the channels with greater force. The risers are concentric and the radial width of the space between them is somewhat small. There is a relatively low rate of flow of water up through the radially outer fuel-containing channels, with which the space between the risers is in communication. (AE C)

  3. Liquid metal reactor air cooling baffle

    DOEpatents

    Hunsbedt, Anstein

    1994-01-01

    A baffle is provided between a relatively hot containment vessel and a relatively cold silo for enhancing air cooling performance. The baffle includes a perforate inner wall positionable outside the containment vessel to define an inner flow riser therebetween, and an imperforate outer wall positionable outside the inner wall to define an outer flow riser therebetween. Apertures in the inner wall allow thermal radiation to pass laterally therethrough to the outer wall, with cooling air flowing upwardly through the inner and outer risers for removing heat.

  4. Liquid metal reactor air cooling baffle

    DOEpatents

    Hunsbedt, A.

    1994-08-16

    A baffle is provided between a relatively hot containment vessel and a relatively cold silo for enhancing air cooling performance. The baffle includes a perforate inner wall positionable outside the containment vessel to define an inner flow riser therebetween, and an imperforate outer wall positionable outside the inner wall to define an outer flow riser therebetween. Apertures in the inner wall allow thermal radiation to pass laterally therethrough to the outer wall, with cooling air flowing upwardly through the inner and outer risers for removing heat. 3 figs.

  5. Stochastic dynamic analysis of marine risers considering Gaussian system uncertainties

    NASA Astrophysics Data System (ADS)

    Ni, Pinghe; Li, Jun; Hao, Hong; Xia, Yong

    2018-03-01

    This paper performs the stochastic dynamic response analysis of marine risers with material uncertainties, i.e. in the mass density and elastic modulus, by using Stochastic Finite Element Method (SFEM) and model reduction technique. These uncertainties are assumed having Gaussian distributions. The random mass density and elastic modulus are represented by using the Karhunen-Loève (KL) expansion. The Polynomial Chaos (PC) expansion is adopted to represent the vibration response because the covariance of the output is unknown. Model reduction based on the Iterated Improved Reduced System (IIRS) technique is applied to eliminate the PC coefficients of the slave degrees of freedom to reduce the dimension of the stochastic system. Monte Carlo Simulation (MCS) is conducted to obtain the reference response statistics. Two numerical examples are studied in this paper. The response statistics from the proposed approach are compared with those from MCS. It is noted that the computational time is significantly reduced while the accuracy is kept. The results demonstrate the efficiency of the proposed approach for stochastic dynamic response analysis of marine risers.

  6. Numerical simulations of vortex-induced vibrations of a flexible riser with different aspect ratiosin uniform and shear currents

    NASA Astrophysics Data System (ADS)

    Duanmu, Yu; Zou, Lu; Wan, De-cheng

    2017-12-01

    This paper aimed at describing numerical simulations of vortex-induced vibrations (VIVs) of a long flexible riser with different length-to-diameter ratio (aspect ratio) in uniform and shear currents. Three aspect ratios were simulated: L/D = 500, 750 and 1 000. The simulation was carried out by the in-house computational fluid dynamics (CFD) solver viv-FOAM-SJTU developed by the authors, which was coupled with the strip method and developed on the OpenFOAM platform. Moreover, the radial basis function (RBF) dynamic grid technique is applied to the viv-FOAM-SJTU solver to simulate the VIV in both in-line (IL) and cross-flow (CF) directions of flexible riser with high aspect ratio. The validation of the benchmark case has been completed. With the same parameters, the aspect ratio shows a significant influence on VIV of a long flexible riser. The increase of aspect ratio exerted a strong effect on the IL equilibrium position of the riser while producing little effect on the curvature of riser. With the aspect ratio rose from 500 to 1 000, the maximum IL mean displacement increased from 3 times the diameter to 8 times the diameter. On the other hand, the vibration mode of the riser would increase with the increase of aspect ratio. When the aspect ratio was 500, the CF vibration was shown as a standing wave with a 3rd order single mode. When the aspect ratio was 1 000, the modal weights of the 5th and 6th modes are high, serving as the dominant modes. The effect of the flow profile on the oscillating mode becomes more and more apparent when the aspect ratio is high, and the dominant mode of riser in shear flow is usually higher than that in uniform flow. When the aspect ratio was 750, the CF oscillations in both uniform flow and shear flow showed multi-mode vibration of the 4th and 5th mode. While, the dominant mode in uniform flow is the 4th order, and the dominant mode in shear flow is the 5th order.

  7. Summary of JIP

    DOT National Transportation Integrated Search

    2008-04-01

    The SCRIM (Steel Catenary Riser Integrity Management) Joint Industry Project was an industry-sponsored initiative, managed and delivered by MCS, to develop industry guidelines for the integrity management of offshore risers. The original scope of the...

  8. Modeling right-lateral offset of a Late Pleistocene terrace riser along the Polaris fault using ground based LiDAR imagery

    NASA Astrophysics Data System (ADS)

    Howle, J. F.; Bawden, G. W.; Hunter, L. E.; Rose, R. S.

    2009-12-01

    High resolution (centimeter level) three-dimensional point-cloud imagery of offset glacial outwash deposits were collected by using ground based tripod LiDAR (T-LiDAR) to characterize the cumulative fault slip across the recently identified Polaris fault (Hunter et al., 2009) near Truckee, California. The type-section site for the Polaris fault is located 6.5 km east of Truckee where progressive right-lateral displacement of middle to late Pleistocene deposits is evident. Glacial outwash deposits, aggraded during the Tioga glaciation, form a flat lying ‘fill’ terrace on both the north and south sides of the modern Truckee River. During the Tioga deglaciation melt water incised into the terrace producing fluvial scarps or terrace risers (Birkeland, 1964). Subsequently, the terrace risers on both banks have been right-laterally offset by the Polaris fault. By using T-LiDAR on an elevated tripod (4.25 m high), we collected 3D high-resolution (thousands of points per square meter; ± 4 mm) point-cloud imagery of the offset terrace risers. Vegetation was removed from the data using commercial software, and large protruding boulders were manually deleted to generate a bare-earth point-cloud dataset with an average data density of over 240 points per square meter. From the bare-earth point cloud we mathematically reconstructed a pristine terrace/scarp morphology on both sides of the fault, defined coupled sets of piercing points, and extracted a corresponding displacement vector. First, the Polaris fault was approximated as a vertical plane that bisects the offset terrace risers, as well as bisecting linear swales and tectonic depressions in the outwash terrace. Then, piercing points to the vertical fault plane were constructed from the geometry of the geomorphic elements on either side of the fault. On each side of the fault, the best-fit modeled outwash plane is projected laterally and the best-fit modeled terrace riser projected upward to a virtual intersection in space, creating a vector. These constructed vectors were projected to intersection with the fault plane, defining statistically significant piercing points. The distance between the coupled set of piercing points, within the plane of the fault, is the cumulative displacement vector. To assess the variability of the modeled geomorphic surfaces, including surface roughness and nonlinearity, we generated a suite of displacement models by systematically incorporating larger areas of the model domain symmetrically about the fault. Preliminary results of 10 models yield an average cumulative displacement of 5.6 m (1 Std Dev = 0.31 m). As previously described, Tioga deglaciation melt water incised into the outwash terrace leaving terrace risers that were subsequently offset by the Polaris fault. Therefore, the age of the Tioga outwash terrace represents a maximum limiting age of the tectonic displacement. Using regional age constraints of 15 to 13 kya for the Tioga outwash terrace (Benson et al., 1990; Clark and Gillespie, 1997; James et al., 2002) and the above model results, we estimate a preliminary minimum fault slip rate of 0.40 ± 0.05 mm/yr for the Polaris type-section site.

  9. 30 CFR 250.1700 - What do the terms “decommissioning”, “obstructions”, and “facility” mean?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... assemblies, umbilicals, manifolds, termination skids, production and pipeline risers, platforms, templates... on the OCS. Facilities include production and pipeline risers, templates, pilings, and any other...

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, W.M.; Tison, M.; Bahoumina, A.

    The tieback of eleven 10 3/4-in., high-pressure risers in Elf Congo`s offshore N`Kossa field used a cold-forge tieback system to create a metal seal. The time-saving tieback method allows for placing the risers in residual tension. The installation work was completed in the fall of 1995. Average time to complete the 10 3/4-in. casing tiebacks, including test and nipple-up and nipple-down times, averaged 52 hr/well. Tiebacks for all three casing strings averaged 90 hr for all surface and subsea operations including BOP test and nipple-up/nipple-down time. Metal sealing of the primary casing annulus has been made practical because the offshoremore » industry has gone toward compact-wellheads and hanging of the completion on a mandrel. Hanging the completion on a mandrel, however, has it own set of considerations. Exact riser length may be difficult to predict before running because the riser must first be locked into the mudline casing hanger and then landed out on the support shoulder in the surface head. Also, a general desire is that riser tieback strings should be in tension after installation. This is not always easy with a passive or dumb hanger and fixed should configuration. Threaded, adjustable mandrel hanger systems exist but can require very close casing string space-out to achieve the desired residual riser tension. The paper describes the objectives, forged sleeves, running sequence, cold forging, and the prototype test.« less

  11. 30 CFR 250.1700 - What do the terms “decommissioning”, “obstructions”, and “facility” mean?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... trees, jumper assemblies, umbilicals, manifolds, termination skids, production and pipeline risers... attached to the seabed on the OCS. Facilities include production and pipeline risers, templates, pilings...

  12. 30 CFR 250.1012 - Required payments for pipeline right-of-way holders.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., pipeline risers, and other facilities and devices associated with the accessory. (2) Your accessory site is... rental includes the areal extent of anchor chains, pipeline risers, and other facilities and devices...

  13. 30 CFR 250.1003 - Installation, testing, and repair requirements for DOI pipelines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... obstructions. (4) Pipeline risers installed after April 1, 1988, shall be protected from physical damage that could result from contact with floating vessels. Riser protection on pipelines installed on or before...

  14. 30 CFR 250.1003 - Installation, testing, and repair requirements for DOI pipelines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... obstructions. (4) Pipeline risers installed after April 1, 1988, shall be protected from physical damage that could result from contact with floating vessels. Riser protection on pipelines installed on or before...

  15. 30 CFR 250.1700 - What do the terms “decommissioning”, “obstructions”, and “facility” mean?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... trees, jumper assemblies, umbilicals, manifolds, termination skids, production and pipeline risers... attached to the seabed on the OCS. Facilities include production and pipeline risers, templates, pilings...

  16. 30 CFR 250.1012 - Required payments for pipeline right-of-way holders.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., pipeline risers, and other facilities and devices associated with the accessory. (2) Your accessory site is... rental includes the areal extent of anchor chains, pipeline risers, and other facilities and devices...

  17. 30 CFR 250.1003 - Installation, testing, and repair requirements for DOI pipelines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... obstructions. (4) Pipeline risers installed after April 1, 1988, shall be protected from physical damage that could result from contact with floating vessels. Riser protection on pipelines installed on or before...

  18. 30 CFR 250.1012 - Required payments for pipeline right-of-way holders.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., pipeline risers, and other facilities and devices associated with the accessory. (2) Your accessory site is... rental includes the areal extent of anchor chains, pipeline risers, and other facilities and devices...

  19. 30 CFR 250.1700 - What do the terms “decommissioning”, “obstructions”, and “facility” mean?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... trees, jumper assemblies, umbilicals, manifolds, termination skids, production and pipeline risers... attached to the seabed on the OCS. Facilities include production and pipeline risers, templates, pilings...

  20. 14. Bottom floor, tower interior showing base of stairway to ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Bottom floor, tower interior showing base of stairway to lantern; details shown of iron castings for newel post, railing, and stair treads and risers. - Block Island Southeast Light, Spring Street & Mohegan Trail at Mohegan Bluffs, New Shoreham, Washington County, RI

  1. Green Infrastructure Tool | EPA Center for Exposure ...

    EPA Pesticide Factsheets

    2016-03-07

    Units option added – SI or US units. Default option is US units Additional options added to FTABLE such as clear FTABLE Significant digits for FTABLE calculations is changed to 5 Previously a default Cd value was used for calculations (under-drain and riser) but now a user-defined value option is given Conversion options added wherever necessary Default values of suction head and hydraulic conductivity are changed based on units selected in infiltration panel Default values of Cd for riser orifice and under-drain textboxes is changed to 0.6. Previously a default increment value of 0.1 is used for all the channel panels but now user can specify the increment

  2. 30 CFR 250.1700 - What do the terms “decommissioning”, “obstructions”, and “facility” mean?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pipeline risers, platforms, templates, pilings, pipelines, pipeline valves, and power cables. (c) Facility... risers, templates, pilings, and any other facility or equipment that constitutes an obstruction such as...

  3. An efficient structural finite element for inextensible flexible risers

    NASA Astrophysics Data System (ADS)

    Papathanasiou, T. K.; Markolefas, S.; Khazaeinejad, P.; Bahai, H.

    2017-12-01

    A core part of all numerical models used for flexible riser analysis is the structural component representing the main body of the riser as a slender beam. Loads acting on this structural element are self-weight, buoyant and hydrodynamic forces, internal pressure and others. A structural finite element for an inextensible riser with a point-wise enforcement of the inextensibility constrain is presented. In particular, the inextensibility constraint is applied only at the nodes of the meshed arc length parameter. Among the virtues of the proposed approach is the flexibility in the application of boundary conditions and the easy incorporation of dissipative forces. Several attributes of the proposed finite element scheme are analysed and computation times for the solution of some simplified examples are discussed. Future developments aim at the appropriate implementation of material and geometric parameters for the beam model, i.e. flexural and torsional rigidity.

  4. Bench and Riser Soil Water Content on Semiarid Hillslopes with Terracettes

    NASA Astrophysics Data System (ADS)

    Heinse, R.; Corrao, M.; Eitel, J.; Link, T. E.

    2015-12-01

    Microtopographic features known as terracettes are found throughout many semiarid rangelands. These path-like features roughly perpendicular to the slope are frequently traversed by grazing animals on steep hillslopes. The soil properties and hydrologic function, however, are virtually unknown. This research aimed to identify differences in soil properties between terracette bench and riser features, and their influence on soil water content for two terracetted sites and two non-terracetted control sites (grazed and ungrazed) in Eastern Washington State. Measurements of volumetric water content (θ_v), bulk density, soil texture, saturated hydraulic conductivity, pH, and ECa_a were collected along with compaction, vegetative cover and cattle density throughout the 2013 and 2014 field seasons. Results show small but significant volumetric water content differences between terracette benches and risers in the upper 10 cm with benches exhibiting higher mean θ_v than risers throughout the year. Soil bulk density on benches (1600 kg m-3^{-3}) was significantly higher than that of risers (1300 kg m-3^{-3}) with no differences in soil texture. The saturated hydraulic conductivity on benches was roughly half of that for risers. No significant soil differences were noted below 20 cm depth. Terracetted sites showed greater field-averaged θ_v compared to non-terracetted sites suggesting a positive trend with animal stocking rates. Higher water content on terracette benches is attributed to shifts in pore size distribution with compaction, and a reduction in root-water uptake due to plant-root impedance. This increased soil water does not however increase forage production as it is not accessible to plants.

  5. Shallow Water Propagation

    DTIC Science & Technology

    2014-09-30

    improvements in single-scattering treatments at stair-step risers in approximations for range dependence; non-uniform depth gridding to treat thin layers...turns out for such problems that preserving accuracy requires conceptually splitting a stair- riser interface into two interfaces separated by a very

  6. 30 CFR 250.530 - When does my casing pressure request approval become invalid?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... request approval become invalid? A casing pressure request becomes invalid when: (a) The casing or riser... different casing or riser on the same well requires a casing pressure request; or (e) A well has more than...

  7. 30 CFR 250.530 - When does my casing pressure request approval become invalid?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... become invalid? A casing pressure request becomes invalid when: (a) The casing or riser pressure... casing or riser on the same well requires a casing pressure request; or (e) A well has more than one...

  8. 30 CFR 250.1708 - What are my BOP inspection and maintenance requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... inspect your BOP system and marine riser at least once every 3 days if weather and sea conditions permit... alternate methods and frequencies to inspect a marine riser. (b) BOP maintenance. You must maintain your BOP...

  9. 30 CFR 250.531 - When does my casing pressure request approval become invalid?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... request approval become invalid? A casing pressure request becomes invalid when: (a) The casing or riser... different casing or riser on the same well requires a casing pressure request; or (e) A well has more than...

  10. 30 CFR 250.617 - What are my BOP inspection and maintenance requirements?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... your BOP system and marine riser at least once each day if weather and sea conditions permit. You may... and frequencies to inspect a marine riser. (b) BOP maintenance. You must maintain your BOP system to...

  11. 30 CFR 250.618 - What are my BOP inspection and maintenance requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... marine riser at least once every 3 days if weather and sea conditions permit. You may use television... frequencies to inspect a marine riser. (b) BOP maintenance. You must maintain your BOP system to ensure that...

  12. 30 CFR 250.617 - What are my BOP inspection and maintenance requirements?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... BOP system and marine riser at least once each day if weather and sea conditions permit. You may use... frequencies to inspect a marine riser. (b) BOP maintenance. You must maintain your BOP system to ensure that...

  13. 30 CFR 250.530 - When does my casing pressure request approval become invalid?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... casing or riser pressure increases by 200 psig over the approved casing pressure request pressure; (b... stimulated; (d) A different casing or riser on the same well requires a casing pressure request; or (e) A...

  14. 30 CFR 250.618 - What are my BOP inspection and maintenance requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... marine riser at least once every 3 days if weather and sea conditions permit. You may use television... frequencies to inspect a marine riser. (b) BOP maintenance. You must maintain your BOP system to ensure that...

  15. 30 CFR 250.1708 - What are my BOP inspection and maintenance requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... inspect your BOP system and marine riser at least once every 3 days if weather and sea conditions permit... alternate methods and frequencies to inspect a marine riser. (b) BOP maintenance. You must maintain your BOP...

  16. 30 CFR 250.531 - When does my casing pressure request approval become invalid?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... request approval become invalid? A casing pressure request becomes invalid when: (a) The casing or riser... different casing or riser on the same well requires a casing pressure request; or (e) A well has more than...

  17. Parametric study on the behavior of an innovative subsurface tension leg platform in ultra-deep water

    NASA Astrophysics Data System (ADS)

    Zhen, Xing-wei; Huang, Yi

    2017-10-01

    This study focuses on a new technology of Subsurface Tension Leg Platform (STLP), which utilizes the shallowwater rated well completion equipment and technology for the development of large oil and gas fields in ultra-deep water (UDW). Thus, the STLP concept offers attractive advantages over conventional field development concepts. STLP is basically a pre-installed Subsurface Sea-star Platform (SSP), which supports rigid risers and shallow-water rated well completion equipment. The paper details the results of the parametric study on the behavior of STLP at a water depth of 3000 m. At first, a general description of the STLP configuration and working principle is introduced. Then, the numerical models for the global analysis of the STLP in waves and current are presented. After that, extensive parametric studies are carried out with regarding to SSP/tethers system analysis, global dynamic analysis and riser interference analysis. Critical points are addressed on the mooring pattern and riser arrangement under the influence of ocean current, to ensure that the requirements on SSP stability and riser interference are well satisfied. Finally, conclusions and discussions are made. The results indicate that STLP is a competitive well and riser solution in up to 3000 m water depth for offshore petroleum production.

  18. Overview of Emic Triggered Chorus Emissions in Cluster Data

    NASA Astrophysics Data System (ADS)

    Grison, B.; Pickett, J. S.; Omura, Y.; Santolik, O.; Engebretson, M. J.; Dandouras, I. S.; Masson, A.; Decreau, P. M.; Adrian, M. L.; Cornilleau Wehrlin, N.

    2010-12-01

    Electromagnetic ion cyclotron (EMIC) triggered emissions have been recently observed onboard the Cluster spacecraft close to the plasmapause in the equatorial region of the magnetosphere (Pickett et al., 2010). The nonlinear mechanism of the wave amplification is the same as for the well known whistler-mode chorus emissions (Omura et al., 2010). The EMIC triggered emissions appear as risers: electromagnetic structures that have a positive frequency drift with time. They can thus be considered as the EMIC analogue of rising frequency whistler-mode chorus emissions. In addition, they propagate away from the magnetic equator. These EMIC risers are not common in Cluster data. We present an overview of the properties of all the identified cases. Risers can be sorted out in two groups: in the first one the starting frequency of EMIC emissions is close to one half of the local proton gyrofrequency and the risers have a clear left-hand polarization. In the second group the risers have an opposite polarization with a starting frequency close to one half of the He+ gyrofrequency. Most of the cases have been detected close to 22 MLT (magnetic local time). This dependence will be investigated to determine if it is linked to the orbit effects or if there is a physical cause.

  19. Promoting stair climbing: stair-riser banners are better than posters... sometimes.

    PubMed

    Olander, Ellinor K; Eves, Frank F; Puig-Ribera, Anna

    2008-04-01

    Stair-riser banners are twice as effective as posters in encouraging stair climbing in shopping centres. This study tested the effectiveness of stair-riser banners in an English train station in 2006-2007. The train station had a 39-step staircase and an adjacent escalator. Baseline observations (3.5 weeks) were followed by 10.5 weeks of a banner intervention supplemented with 3 weeks of a poster intervention. Both poster and banner featured the message 'Stair climbing burns more calories per minute than jogging. Take the stairs'. Ascending escalator and stair users (N=36,239) were coded for gender. Analyses, controlling for effects of gender and pedestrian traffic volume, revealed no significant change in stair climbing between baseline (40.6%) and the banner intervention (40.9%; p=0.98). Addition of the poster increased stair climbing (44.3%; OR=1.36, 95% CIs 1.16-1.60, p<0.001), with the effect reduced at higher pedestrian traffic volumes. While stair-riser banners had no effect, the poster intervention increased stair climbing. The high pedestrian volumes as the wave of disembarking passengers seek to leave the station would have obscured the visibility of the banner for many commuters. Thus stair-riser banners appear unsuitable point-of-choice prompts in stations where pedestrian traffic volume is high.

  20. The effectiveness of an adhesively bonded composite patch repair as applied to a transport aircraft lower wing skin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruschau, J.J.; Coate, J.E.

    1996-12-31

    Specimens were machined from lower wing skin extrusions of a transport aircraft, precracked under fatigue loading, repaired with a boron/epoxy patch, and subsequently fatigue tested under simulated flight loading conditions to evaluate the effectiveness of an adhesively bonded repair patch. Testing was performed at RT and -54{degrees}C for two configurations: one with the crack running up the integral stiffener (riser), the other running down the riser towards the outer skin surface. Cracks were initiated from a single 6.35 mm diameter hole located in the riser portion of the 7075-T6 wing skin material. Ultrasonic inspections were performed during fatigue loading tomore » determine crack growth and damage underneath the patch. Limited results show the adhesively bonded patch was successful in stopping or greatly reducing any further crack growth. Under laboratory air conditions, no crack growth occurred following 30,000 equivalent flight hours, double the expected life of the patched structure. Similarly at -54{degrees}C, no crack growth was observed for a patched crack growing up the riser following 15,000 EFH. For the case of a crack growing down the riser at the lower test temperature, some crack growth was measured, though at a greatly reduced rate.« less

  1. RELIABLE RADIOGRAPHIC INSPECTION OF FLEXIBLE RISERS FOR THE OIL INDUSTRY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almeida, Romulo M.; Rebello, Joao Marcos A.; Vaz, Murilo A.

    2010-02-22

    Flexible risers are composite tubular structures manufactured by the concentric assemblage of cylindrical polymeric and helically wound metallic layers employed to convey pressurized fluids such as oil, gas and water in the ocean environment. The metallic layers account for the flexible risers' structural strength and are dimensioned according to the static and dynamic loads. They are usually installed in a free hanging catenary configuration and are subjected to the direct action of waves and marine currents and wave induced motions from the oil production platform. The fatigue rupture of wire armours in the end fitting or within the riser segmentmore » protected by the bend stiffener is an object of major concern. Integrity models have been developed, however inspection techniques are mandatory to ensure that failure is detected. Gammagraphy has been used as a common inspection technique in all regions of the flexible riser, mainly with the single wall-single view method. On the other side, there is not any qualified radiographic procedure to this kind of structure. Radiographic simulation was adopted and its validation with actual gammagraphies and establishment of radiographic parameters to complex radiation geometries were done. Results show the viability of the radiographic inspection analyzing the armour wires' rupture and the displacement between wires.« less

  2. Reliable Radiographic Inspection of Flexible Risers for the Oil Industry

    NASA Astrophysics Data System (ADS)

    Almeida, Rômulo M.; Rebello, Joao Marcos A.; Vaz, Murilo A.

    2010-02-01

    Flexible risers are composite tubular structures manufactured by the concentric assemblage of cylindrical polymeric and helically wound metallic layers employed to convey pressurized fluids such as oil, gas and water in the ocean environment. The metallic layers account for the flexible risers' structural strength and are dimensioned according to the static and dynamic loads. They are usually installed in a free hanging catenary configuration and are subjected to the direct action of waves and marine currents and wave induced motions from the oil production platform. The fatigue rupture of wire armours in the end fitting or within the riser segment protected by the bend stiffener is an object of major concern. Integrity models have been developed, however inspection techniques are mandatory to ensure that failure is detected. Gammagraphy has been used as a common inspection technique in all regions of the flexible riser, mainly with the single wall-single view method. On the other side, there is not any qualified radiographic procedure to this kind of structure. Radiographic simulation was adopted and its validation with actual gammagraphies and establishment of radiographic parameters to complex radiation geometries were done. Results show the viability of the radiographic inspection analyzing the armour wires' rupture and the displacement between wires.

  3. Study of cluster behavior in the riser of CFB by the DSMC method

    NASA Astrophysics Data System (ADS)

    Liu, H. P.; Liu, D. Y.; Liu, H.

    2010-03-01

    The flow behaviors of clusters in the riser of a two-dimensional (2D) circulating fluidized bed was numerically studied based on the Euler-Lagrangian approach. Gas turbulence was modeled by means of Large Eddy Simulation (LES). Particle collision was modeled by means of the direct simulation Monte Carlo (DSMC) method. Clusters' hydrodynamic characteristics are obtained using a cluster identification method proposed by sharrma et al. (2000). The descending clusters near the wall region and the up- and down-flowing clusters in the core were studied separately due to their different flow behaviors. The effects of superficial gas velocity on the cluster behavior were analyzed. Simulated results showed that near wall clusters flow downward and the descent velocity is about -45 cm/s. The occurrence frequency of the up-flowing cluster is higher than that of down-flowing cluster in the core of riser. With the increase of superficial gas velocity, the solid concentration and occurrence frequency of clusters decrease, while the cluster axial velocity increase. Simulated results were in agreement with experimental data. The stochastic method used in present paper is feasible for predicting the cluster flow behavior in CFBs.

  4. Reconstruction of Twist Torque in Main Parachute Risers

    NASA Technical Reports Server (NTRS)

    Day, Joshua D.

    2015-01-01

    The reconstruction of twist torque in the Main Parachute Risers of the Capsule Parachute Assembly System (CPAS) has been successfully used to validate CPAS Model Memo conservative twist torque equations. Reconstruction of basic, one degree of freedom drop tests was used to create a functional process for the evaluation of more complex, rigid body simulation. The roll, pitch, and yaw of the body, the fly-out angles of the parachutes, and the relative location of the parachutes to the body are inputs to the torque simulation. The data collected by the Inertial Measurement Unit (IMU) was used to calculate the true torque. The simulation then used photogrammetric and IMU data as inputs into the Model Memo equations. The results were then compared to the true torque results to validate the Model Memo equations. The Model Memo parameters were based off of steel risers and the parameters will need to be re-evaluated for different materials. Photogrammetric data was found to be more accurate than the inertial data in accounting for the relative rotation between payload and cluster. The Model Memo equations were generally a good match and when not matching were generally conservative.

  5. 30 CFR 550.160 - When will BOEM grant me a right-of-use and easement, and what requirements must I meet?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... rental includes the areal extent of anchor chains, pipeline risers, and other equipment associated with..., pipeline risers, and other equipment associated with the platform, artificial island, or installation or...

  6. 30 CFR 550.160 - When will BOEM grant me a right-of-use and easement, and what requirements must I meet?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... rental includes the areal extent of anchor chains, pipeline risers, and other equipment associated with..., pipeline risers, and other equipment associated with the platform, artificial island, or installation or...

  7. 75 FR 17708 - Kinder Morgan Louisiana Pipeline LLC; Notice of Request Under Blanket Authorization

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-07

    ... authorization to construct and operate a new tap, including ball valve and riser and approximately 15 feet of 8..., riser, 15-feet of 8-inch diameter piping and such other appurtenant facilities as deemed necessary to...

  8. 30 CFR 550.160 - When will BOEM grant me a right-of-use and easement, and what requirements must I meet?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... rental includes the areal extent of anchor chains, pipeline risers, and other equipment associated with..., pipeline risers, and other equipment associated with the platform, artificial island, or installation or...

  9. Dynamic Responses of Flexible Cylinders with Low Mass Ratio

    NASA Astrophysics Data System (ADS)

    Olaoye, Abiodun; Wang, Zhicheng; Triantafyllou, Michael

    2017-11-01

    Flexible cylinders with low mass ratios such as composite risers are attractive in the offshore industry because they require lower top tension and are less likely to buckle under self-weight compared to steel risers. However, their relatively low stiffness characteristics make them more vulnerable to vortex induced vibrations. Additionally, numerical investigation of the dynamic responses of such structures based on realistic conditions is limited by high Reynolds number, complex sheared flow profile, large aspect ratio and low mass ratio challenges. In the framework of Fourier spectral/hp element method, the current technique employs entropy-viscosity method (EVM) based large-eddy simulation approach for flow solver and fictitious added mass method for structure solver. The combination of both methods can handle fluid-structure interaction problems at high Reynolds number with low mass ratio. A validation of the numerical approach is provided by comparison with experiments.

  10. Association between abnormal nocturnal blood pressure profile and dementia in Parkinson's disease.

    PubMed

    Tanaka, Ryota; Shimo, Yasushi; Yamashiro, Kazuo; Ogawa, Takashi; Nishioka, Kenya; Oyama, Genko; Umemura, Atsushi; Hattori, Nobutaka

    2018-01-01

    Circadian blood pressure alterations are frequently observed in Parkinson's disease, but the association between these changes and dementia in the condition remains unclear. Here, we assess the relationship between abnormal nocturnal blood pressure profiles and dementia in Parkinson's disease. We enrolled 137 patients with Parkinson's disease, who underwent 24 h ambulatory blood pressure monitoring, following cognitive and clinical assessment. Twenty-seven patients (19.7%) were diagnosed with dementia in this cohort. We observed significant associations of dementia with age, male gender, Hoehn-Yahr (H-Y) stage, diabetes mellitus, history of stroke, presence of cerebrovascular lesions on MRI, and orthostatic hypotension. Univariate logistic regression analysis showed that among the patterns of nocturnal blood pressure profiles, the riser pattern was significantly associated with dementia (OR 11.6, 95%CI: 2.14-215.0, P < 0.01), and this trend was observed after adjusting for all confounding factors except orthostatic hypotension (OR 19.2, 95%CI: 1.12-1960.3, P = 0.04). However, coexistence of a riser pattern and orthostatic hypotension was related to a higher prevalence of dementia (45.2%) than was a riser pattern alone (9.5%). Furthermore, coexistence of a riser pattern and orthostatic hypotension was significantly more associated with dementia than was a riser pattern alone, even after adjusting for confounders (OR 1625.1, 95%CI: 21.9-1343909.5, P < 0.01). Our results suggest a relationship between a riser pattern coexisting with orthostatic hypotension and dementia in Parkinson's disease. Further prospective studies are warranted to investigate whether abnormal nocturnal blood pressure profiles predict dementia in Parkinson's disease. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Thermal-Hydraulic Analysis of an Experimental Reactor Cavity Cooling System with Air. Part I: Experiments; Part II: Separate Effects Tests and Modeling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Corradin, Michael; Anderson, M.; Muci, M.

    This experimental study investigates the thermal hydraulic behavior and the heat removal performance for a scaled Reactor Cavity Cooling System (RCCS) with air. A quarter-scale RCCS facility was designed and built based on a full-scale General Atomics (GA) RCCS design concept for the Modular High Temperature Gas Reactor (MHTGR). The GA RCCS is a passive cooling system that draws in air to use as the cooling fluid to remove heat radiated from the reactor pressure vessel to the air-cooled riser tubes and discharged the heated air into the atmosphere. Scaling laws were used to preserve key aspects and to maintainmore » similarity. The scaled air RCCS facility at UW-Madison is a quarter-scale reduced length experiment housing six riser ducts that represent a 9.5° sector slice of the full-scale GA air RCCS concept. Radiant heaters were used to simulate the heat radiation from the reactor pressure vessel. The maximum power that can be achieved with the radiant heaters is 40 kW with a peak heat flux of 25 kW per meter squared. The quarter-scale RCCS was run under different heat loading cases and operated successfully. Instabilities were observed in some experiments in which one of the two exhaust ducts experienced a flow reversal for a period of time. The data and analysis presented show that the RCCS has promising potential to be a decay heat removal system during an accident scenario.« less

  12. Decision Making: New Paradigm for Education.

    ERIC Educational Resources Information Center

    Wales, Charles E.; And Others

    1986-01-01

    Defines education's new paradigm as schooling based on decision making, the critical thinking skills serving it, and the knowledge base supporting it. Outlines a model decision-making process using a hypothetical breakfast problem; a late riser chooses goals, generates ideas, develops an action plan, and implements and evaluates it. (4 references)…

  13. Computational Fluid Dynamics–Discrete Element Method (CFD-DEM) Study of Mass-Transfer Mechanisms in Riser Flow

    PubMed Central

    2017-01-01

    We report a computational fluid dynamics–discrete element method (CFD-DEM) simulation study on the interplay between mass transfer and a heterogeneous catalyzed chemical reaction in cocurrent gas-particle flows as encountered in risers. Slip velocity, axial gas dispersion, gas bypassing, and particle mixing phenomena have been evaluated under riser flow conditions to study the complex system behavior in detail. The most important factors are found to be directly related to particle cluster formation. Low air-to-solids flux ratios lead to more heterogeneous systems, where the cluster formation is more pronounced and mass transfer more influenced. Falling clusters can be partially circumvented by the gas phase, which therefore does not fully interact with the cluster particles, leading to poor gas–solid contact efficiencies. Cluster gas–solid contact efficiencies are quantified at several gas superficial velocities, reaction rates, and dilution factors in order to gain more insight regarding the influence of clustering phenomena on the performance of riser reactors. PMID:28553011

  14. Computational Fluid Dynamics-Discrete Element Method (CFD-DEM) Study of Mass-Transfer Mechanisms in Riser Flow.

    PubMed

    Carlos Varas, Álvaro E; Peters, E A J F; Kuipers, J A M

    2017-05-17

    We report a computational fluid dynamics-discrete element method (CFD-DEM) simulation study on the interplay between mass transfer and a heterogeneous catalyzed chemical reaction in cocurrent gas-particle flows as encountered in risers. Slip velocity, axial gas dispersion, gas bypassing, and particle mixing phenomena have been evaluated under riser flow conditions to study the complex system behavior in detail. The most important factors are found to be directly related to particle cluster formation. Low air-to-solids flux ratios lead to more heterogeneous systems, where the cluster formation is more pronounced and mass transfer more influenced. Falling clusters can be partially circumvented by the gas phase, which therefore does not fully interact with the cluster particles, leading to poor gas-solid contact efficiencies. Cluster gas-solid contact efficiencies are quantified at several gas superficial velocities, reaction rates, and dilution factors in order to gain more insight regarding the influence of clustering phenomena on the performance of riser reactors.

  15. Core disruptive accident margin seal

    DOEpatents

    Golden, Martin P.

    1979-01-01

    Apparatus for sealing the annulus defined within a substantially cylindrical rotatable riser assembly and plug combination of a nuclear reactor closure head. The apparatus comprises an inflatable sealing mechanism disposed in one portion of the riser assembly near the annulus such that upon inflation the sealing mechanism is radially actuated against the other portion of the riser assembly thereby sealing the annulus. The apparatus further comprises a connecting mechanism which places one end of the sealing mechanism in fluid communication with the reactor cover gas so that overpressurization of the reactor cover gas will increase the radial actuation of the sealing mechanism thus enhancing sealing of the annulus.

  16. Performance of thermal sprayed aluminium coatings in the splash zone and for riser service

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischer, K.P.; Rosbrook, T.; Thomason, W.H.

    1994-12-31

    Historically, the coatings used in the splash zone have been either heavy duty coal tar epoxy or a glassflake epoxy. In 1982 Conoco justified a minimum 20 year service life for a sealed thermal sprayed aluminium (TSA) coating for the Hutton TLP risers and tethers. In 1984 the Hutton TLP was installed with 200 microns thickness TSA as the corrosion protection coating and without adding a corrosion allowance. After eight years service the TSA coating on the production risers and tethers is still in good condition. It was noted that the splash zone area was indistinguishable from the remainder ofmore » the inspected components. However, there was a noticeable difference between the production risers and the tethers. The tethers having a vinyl sealer showed a blistered surface while the risers with a silicone sealer did not show any blistering. No corrosion has been observed underneath any of the blisters. The importance of adequate sealers in connection with blistering has been documented by testing. The excellent long term performance of TSA coating in the splash zone has been further documented by the results of field studies published in the last few years. These experiences indicate that TSA coatings properly applied and with the use of specific sealer systems may provide a service life in excess of 30 years with no required maintenance.« less

  17. ATI SAA Annex 3 Button Tensile Test Report I

    NASA Technical Reports Server (NTRS)

    Tang, Henry H.

    2013-01-01

    This report documents the results of a study carried out under Splace Act Agreement SAA-EA-10-004 between the National Aeronautics and Space Administration (NASA) and Astro Technology Incorpporated (ATI). NASA and ATI have entered into this agreement to collaborate on the development of technologies that can benefit both the US government space programs and the oil and gas industry. The report documents the results of a test done on an adnesive system for attaching new monitoring sensor devices to pipelines under Annex III of SAA-EA-10-004: "Proof-of-Concept Design and Testing of a Post Installed Sensing Device on Subsea Risers and Pipelines". The tasks of Annex III are to design and test a proof-of-concept sensing device for in-situ installation on pipelines, risers, or other structures deployed in deep water. The function of the sensor device is to measure various signals such as strain, stress and temperature. This study complements the work done, in Annex I of the SAA, on attaching a fiber optic sensing device to pipe via adhesive bonding. Both Annex I and Annex III studies were conducted in the Crew and Thermal System Division (CTSD) at the Johnson Space Center (JSC) in collaboration with ATI.

  18. Development and Testing of a Post-Installable Deepwater Monitoring System Using Fiber-Optic Sensors

    NASA Technical Reports Server (NTRS)

    Seaman, Calvin H.; Brower, David V.; Le, Suy Q.; Tang, Henry H.

    2015-01-01

    This paper addresses the design and development of a fiber-optic monitoring system that can be deployed on existing deepwater risers and flowlines; and provides a summary of test article fabrication and the subsequent laboratory testing performed at the National Aeronautics and Space Administration-Johnson Space Center (NASA-JSC). A major challenge of a post-installed instrumentation system is to ensure adequate coupling between the instruments and the riser or flowline of interest. This work investigates the sensor coupling for pipelines that are suspended in a water column (from topside platform to seabed) using a fiber-optic sensor clamp and subsea bonding adhesive. The study involved the design, fabrication, and test of several prototype clamps that contained fiber-optic sensors. A mold was produced by NASA using 3-D printing methods that allowed the casting of polyurethane clamp test articles to accommodate 4-inch and 8-inch diameter pipes. The prototype clamps were installed with a subsea adhesive in a "wet" environment and then tested in the NASA Structures Test Laboratory (STL). The tension, compression, and bending test data showed that the prototype sensor clamps achieved good structural coupling, and could provide high quality strain measurement for active monitoring.

  19. Moving evidence-based drug abuse prevention programs from basic science to practice: "bridging the efficacy-effectiveness interface".

    PubMed

    August, Gerald J; Winters, Ken C; Realmuto, George M; Tarter, Ralph; Perry, Cheryl; Hektner, Joel M

    2004-01-01

    This article examines the challenges faced by developers of youth drug abuse prevention programs in transporting scientifically proven or evidence-based programs into natural community practice systems. Models for research on the transfer of prevention technology are described with specific emphasis given to the relationship between efficacy and effectiveness studies. Barriers that impede the successful integration of efficacy methods within effectiveness studies (e.g., client factors, practitioner factors, intervention structure characteristics, and environmental and organizational factors) are discussed. We present a modified model for program development and evaluation that includes a new type of research design, the hybrid efficacy-effectiveness study that addresses program transportability. The utility of the hybrid study is illustrated in the evaluation of the Early Risers "Skills for Success" prevention program.

  20. The Lighthouse Project.

    ERIC Educational Resources Information Center

    LeRose, Barbara; And Others

    1979-01-01

    The project is based on a general systems approach. Developmental stage theory is employed as a starting point, and the developmental "minitasks" which act as stair risers from one developmental level to another are carried through with the use of Bloom's cognitive taxonomy. (Author/DLS)

  1. Development Of An 80'-Diameter Ribbon Drogue Parachute For The NASA X-38 Vehicle

    NASA Technical Reports Server (NTRS)

    Behr, Vance L.; Wolf, Dean F.; Rutledge, Bruce A.; Hillebrandt, F. David

    2001-01-01

    The NASA X-38 program required a larger, more robust drogue parachute. A multi-organizational team from NASA, Sandia National Laboratories, United Space Alliance, and Pioneer Aerospace Corporation has developed and tested a new 80-ft.-dia., quarter-spherical, ribbon drogue parachute. The design requirements, design specifics, margin analyses, and results of testing are all discussed herein. Some of the weight advantages of switching from Kevlar to Zylon for radial, line and riser materials are presented.

  2. Development of High-Performance Cast Crankshafts. Final Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, Mark E

    The objective of this project was to develop technologies that would enable the production of cast crankshafts that can replace high performance forged steel crankshafts. To achieve this, the Ultimate Tensile Strength (UTS) of the new material needs to be 850 MPa with a desired minimum Yield Strength (YS; 0.2% offset) of 615 MPa and at least 10% elongation. Perhaps more challenging, the cast material needs to be able to achieve sufficient local fatigue properties to satisfy the durability requirements in today’s high performance gasoline and diesel engine applications. The project team focused on the development of cast steel alloysmore » for application in crankshafts to take advantage of the higher stiffness over other potential material choices. The material and process developed should be able to produce high-performance crankshafts at no more than 110% of the cost of current production cast units, perhaps the most difficult objective to achieve. To minimize costs, the primary alloy design strategy was to design compositions that can achieve the required properties with minimal alloying and post-casting heat treatments. An Integrated Computational Materials Engineering (ICME) based approach was utilized, rather than relying only on traditional trial-and-error methods, which has been proven to accelerate alloy development time. Prototype melt chemistries designed using ICME were cast as test specimens and characterized iteratively to develop an alloy design within a stage-gate process. Standard characterization and material testing was done to validate the alloy performance against design targets and provide feedback to material design and manufacturing process models. Finally, the project called for Caterpillar and General Motors (GM) to develop optimized crankshaft designs using the final material and manufacturing processing path developed. A multi-disciplinary effort was to integrate finite element analyses by engine designers and geometry-specific casting simulations with existing materials models to optimize crankshaft cost and performance. Prototype crankshafts of the final design were to be produced and validated using laboratory bench testing and on-engine durability testing. ICME process simulation tools were used to investigate a broad range of processing concepts. These concepts included casting orientation, various mold and core materials, and various filling and feeding strategies. Each crankshaft was first simulated without gating and risers, which is termed natural solidification. The natural solidification results were used as a baseline for strategy development of each concept. Casting process simulations and ICME tools were proven to be reasonable predictors of real world results. Potential alloys were developed that could meet the project material property goals with appropriate normalization and temper treatments. For the alloys considered, post-normalization temper treatments proved to be necessary to achieve the desired yield strengths and elongations and appropriate heat treatments were designed using ICME tools. The experimental data of all the alloys were analyzed in combination with ICME tools to establish chemistry-process-structure relations. Several GM small gas engine (SGE) crankshafts were successfully cast in sand molds using two different sprue, runner, gate, riser, chill designs. These crankshafts were cast in two different steel alloys developed during the project, but casting finishing (e.g. riser removal) remains a cost challenge. A long list of future work was left unfinished when this project was unexpectedly terminated.« less

  3. Mass transfer effects in a gasification riser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Breault, Ronald W.; Li, Tingwen; Nicoletti, Phillip

    2013-07-01

    In the development of multiphase reacting computational fluid dynamics (CFD) codes, a number of simplifications were incorporated into the codes and models. One of these simplifications was the use of a simplistic mass transfer correlation for the faster reactions and omission of mass transfer effects completely on the moderate speed and slow speed reactions such as those in a fluidized bed gasifier. Another problem that has propagated is that the mass transfer correlation used in the codes is not universal and is being used far from its developed bubbling fluidized bed regime when applied to circulating fluidized bed (CFB) risermore » reactors. These problems are true for the major CFD codes. To alleviate this problem, a mechanistic based mass transfer coefficient algorithm has been developed based upon an earlier work by Breault et al. This fundamental approach uses the local hydrodynamics to predict a local, time varying mass transfer coefficient. The predicted mass transfer coefficients and the corresponding Sherwood numbers agree well with literature data and are typically about an order of magnitude lower than the correlation noted above. The incorporation of the new mass transfer model gives the expected behavior for all the gasification reactions evaluated in the paper. At the expected and typical design values for the solid flow rate in a CFB riser gasifier an ANOVA analysis has shown the predictions from the new code to be significantly different from the original code predictions. The new algorithm should be used such that the conversions are not over predicted. Additionally, its behaviors with changes in solid flow rate are consistent with the changes in the hydrodynamics.« less

  4. 30 CFR 250.527 - What must I include in my casing pressure request?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... casing/riser calculated MAWOPs; (h) All casing/riser pre-bleed down pressures; (i) Shut-in tubing... test (oil, gas, basic sediment, and water); (l) Well status (shut-in, temporarily abandoned, producing, injecting, or gas lift); (m) Well type (dry tree, hybrid, or subsea); (n) Date of diagnostic test; (o) Well...

  5. The Early Risers Preventive Intervention: Testing for Six-year Outcomes and Mediational Processes

    ERIC Educational Resources Information Center

    Bernat, Debra H.; August, Gerald J.; Hektner, Joel M.; Bloomquist, Michael L.

    2007-01-01

    We examined effects of the Early Risers "Skills for Success" early-age-targeted prevention program on serious conduct problems following 5 years of continuous intervention and one year of follow-up. We also examined if intervention effects on proximally-targeted variables found after 3 years mediated intervention effects on conduct…

  6. Tibial plateau fracture following gracilis-semitendinosus anterior cruciate ligament reconstruction: The tibial tunnel stress-riser.

    PubMed

    Sundaram, R O; Cohen, D; Barton-Hanson, N

    2006-06-01

    Tibial plateau fractures following anterior cruciate ligament (ACL) reconstruction are extremely rare. This is the first reported case of a tibial plateau fracture following four-strand gracilis-semitendinosus autograft ACL reconstruction. The tibial tunnel alone may behave as a stress riser which can significantly reduce bone strength.

  7. Development of Millimeter-Wave Velocimetry and Acoustic Time-of-Flight Tomography for Measurements in Densely Loaded Gas-Solid Riser Flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fort, James A.; Pfund, David M.; Sheen, David M.

    2007-04-01

    The MFDRC was formed in 1998 to advance the state-of-the-art in simulating multiphase turbulent flows by developing advanced computational models for gas-solid flows that are experimentally validated over a wide range of industrially relevant conditions. The goal was to transfer the resulting validated models to interested US commercial CFD software vendors, who would then propagate the models as part of new code versions to their customers in the US chemical industry. Since the lack of detailed data sets at industrially relevant conditions is the major roadblock to developing and validating multiphase turbulence models, a significant component of the work involvedmore » flow measurements on an industrial-scale riser contributed by Westinghouse, which was subsequently installed at SNL. Model comparisons were performed against these datasets by LANL. A parallel Office of Industrial Technology (OIT) project within the consortium made similar comparisons between riser measurements and models at NETL. Measured flow quantities of interest included volume fraction, velocity, and velocity-fluctuation profiles for both gas and solid phases at various locations in the riser. Some additional techniques were required for these measurements beyond what was currently available. PNNL’s role on the project was to work with the SNL experimental team to develop and test two new measurement techniques, acoustic tomography and millimeter-wave velocimetry. Acoustic tomography is a promising technique for gas-solid flow measurements in risers and PNNL has substantial related experience in this area. PNNL is also active in developing millimeter wave imaging techniques, and this technology presents an additional approach to make desired measurements. PNNL supported the advanced diagnostics development part of this project by evaluating these techniques and then by adapting and developing the selected technology to bulk gas-solids flows and by implementing them for testing in the SNL riser testbed.« less

  8. A novel circulating loop bioreactor with cells immobilized in loofa ( Luffa cylindrica) sponge for the bioconversion of raw cassava starch to ethanol.

    PubMed

    Roble, N D; Ogbonna, J C; Tanaka, H

    2003-02-01

    A circulating loop bioreactor (CLB) with cells immobilized in loofa sponge was constructed for simultaneous aerobic and anaerobic processes. The CLB consists of an aerated riser and a non-aerated downcomer column connected at the top and bottom by cylindrical pipes. Ethanol production from raw cassava starch was investigated in the CLB. Aspergillus awamori IAM 2389 and Saccharomyces cerevisiae IR2 immobilized on loofa sponge were placed, respectively, in the aerated riser column and non-aerated downcomer column. Both alpha-amylase and glucoamylase activities increased as the aeration rate was increased. Ethanol yield and productivity increased with an increase in the aeration rate up to 0.5 vvm, but decreased at higher aeration rates. The CLB was operated at an aeration rate of 0.5 vvm for more than 600 h, resulting in an average ethanol productivity and yield from raw cassava starch of 0.5 g-ethanol l(-1) x h(-1) and 0.45 g ethanol/g starch, respectively. In order to increase ethanol productivity, it was necessary to increase the dissolved oxygen (DO) concentration in the riser column and decrease the DO concentration in the downcomer column. However, increasing the aeration rate resulted in increases in the DO concentration in both the riser and the downcomer columns. At high aeration rate, there was no significant difference in the DO concentration in the riser and downcomer columns. The aeration rate was therefore uncoupled from the liquid circulation by attaching a time-controlled valve in the upper connecting pipe. By optimizing the time and frequency of valve opening, and operation at high aeration rate, it was possible to maintain a very high DO concentration in the riser column and a low DO concentration in the downcomer column. Under these conditions, ethanol productivity increased by more than 100%, to 1.17 g l(-1) x h(-1).

  9. Plant Functional Traits on Green Risers and Brown Treads of Periglacial Patterned Ground at Glacier National Park, Montana

    NASA Astrophysics Data System (ADS)

    Apple, M. E.; Ricketts, M. K.

    2016-12-01

    On the stair-stepped solifluction terraces of the periglacial patterned ground at Glacier National Park, Montana, the clearly visible striped pattern of green alternating with brown is formed by contrasts in the percent cover of plants with different functional traits. The sloping green risers dominated by the mat-forming dwarf shrubs, Dryas octopetela (Mountain Dryad) and Salix arctica (Arctic Willow) alternate with the relatively flat, sparsely covered brown rocky treads which are inhabitated by herbaceous, and often taprooted plants. Eleven species were restricted to the brown treads, including the rare arctic-alpine species Papaver pygmaeum (Pygmy Poppy), Aqiulegia jonesii (Jones' Columbine), Draba macounii, and Erigeron lanatus. Of these, the first three arise from taproots or branched rootcrowns. They are restricted to the brown rocky treads while E. lanatus arises from a caudex and grows on the treads and risers. The relative abundance of rare plants was significantly higher on the brown treads and no rare species were restricted to the green risers. The community weighted trait means were significantly higher for Raunkiaer cryptophytes and hemicryptophytes, graminoid, herbaceous and rosetted forms, and stolons, Underground traits varied significantly as well, since taproots, caudices, and other substantial roots had higher incidences on the brown treads than on the green risers. The brown, rocky treads are relatively flat with low percent plant cover and likely a water-stressed environment, hence the substantial investment in underground structures. In contrast, the sloped green risers are essentially covered by the mat-forming dwarf shrubs, D. octopetela and S. arctica, which augment their woody roots with the anchorage of adventitious roots and which provide shade and water retention for other plants, including seedlings of Abies lasiocarpa (Subalpine fir) and Pinus albicaulus (Whitebark Pine). Water from summer thunderstorms and seasonal melting supplies the periglacial patterned ground, which is by definition close to Glacier National Park's vanishing snowfields and glaciers, so their loss will likely influence water availability for these alpine plants.

  10. Authentic Assessment and Student Performance in Inclusive Schools. Research Institute on Secondary Education Reform (RISER) for Youth with Disabilities Brief.

    ERIC Educational Resources Information Center

    King, M. Bruce; Schroeder, Jennifer; Chawszczewski, David

    This research brief explores the extent to which teacher-designed assessments are authentic in inclusive secondary schools and how students with and without disabilities perform on these assessments. Data come from three high schools that are participating in a 5-year national study conducted by the Research Institute on Secondary Education Reform…

  11. Vortex-Induced Vibrations of a Riser with Design Variations

    DTIC Science & Technology

    2016-06-19

    explain the similarities and differences in VIV responses for the two different orientations of the same structure in the same fluid flow field . Figure...length, bending and torsional deformation can be ignored. In comparison to the potential energy in axial strain, bending energy drops off rapidly...with slenderness (diameter/length higher than ~50). Similarly, torsional energy is near zero in bluff, symmetrical and slender structures [Zueck

  12. Human Strength Capabilities for the Operation of Parachute Ripcords and Riser Releases

    DTIC Science & Technology

    1983-10-01

    Parachutes Human Strength Ripcords Isometric Force Riser Releases Anthropometry 0 24 SITRACT (Con i, e on reveres. id. If neceay and Identify by block numb... Anthropometry . . . .. .. ... .. 41 DISCUSSIONS . . . . . . . . . . . . . 43 Other Studies . . . . . . . . . 44 CONCLUSIONS AND RECOMMENDATIONS...tendency to produce greater forces. Anthropometry . Results of the anthropometric measurements are given in Table 11, listing the means, standard

  13. Secondary School Reform, Inclusion, and Authentic Assessment. Research Institute on Secondary Education Reform (RISER) for Youth with Disabilities Brief.

    ERIC Educational Resources Information Center

    Braden, Jeffery P.; Schroeder, Jennifer L.; Buckley, Jacquelyn A.

    The Research Institute on Secondary Education Reform for Youth with Disabilities (RISER) has identified Schools of Authentic and Inclusive Learning (SAIL) to explore whether and how secondary students with disabilities are included in secondary education reform. In this brief, the literature describing the intersection of reform, inclusion, and…

  14. Numerical Modeling of Reactive Multiphase Flow for FCC and Hot Gas Desulfurization Circulating Fluidized Beds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Aubrey L.

    2005-07-01

    This work was carried out to understand the behavior of the solid and gas phases in a CFB riser. Only the riser is modeled as a straight pipe. A model with linear algebraic approximation to solids viscosity of the form, {musubs} = 5.34{epsisubs}, ({espisubs} is the solids volume fraction) with an appropriate boundary condition at the wall obtained by approximate momentum balance solution at the wall to acount for the solids recirculation is tested against experimental results. The work done was to predict the flow patterns in the CFB risers from available experimental data, including data from a 7.5-cm-ID CFBmore » riser at the Illinois Institute of Technology and data from a 20.0-cm-ID CFB riser at the Particulate Solid Research, Inc., facility. This research aims at modeling the removal of hydrogen sulfide from hot coal gas using zinc oxide as the sorbent in a circulating fluidized bed and in the process indentifying the parameters that affect the performance of the sulfidation reactor. Two different gas-solid reaction models, the unreacted shrinking core (USC) and the grain model were applied to take into account chemical reaction resistances. Also two different approaches were used to affect the hydrodynamics of the process streams. The first model takes into account the effect of micro-scale particle clustering by adjusting the gas-particle drag law and the second one assumes a turbulent core with pseudo-steady state boundary condition at the wall. A comparison is made with experimental results.« less

  15. Abnormal Circadian Blood Pressure Profile as a Prognostic Marker in Patients with Nonischemic Dilated Cardiomyopathy.

    PubMed

    Sawamura, Akinori; Okumura, Takahiro; Takeshita, Kyosuke; Watanabe, Naoki; Kano, Naoaki; Mori, Hiroaki; Fukaya, Kenji; Morimoto, Ryota; Hirashiki, Akihiro; Bando, Yasuko Kureishi; Murohara, Toyoaki

    An abnormal circadian blood pressure (BP) profile is considered a risk factor for cardiovascular disease. However, its significance in heart failure patients with nonischemic etiology is unknown. Herein, we investigated the prognostic value of a circadian BP profile in patients with nonischemic dilated cardiomyopathy (NIDCM). We enrolled 114 NIDCM patients (76 males, mean age 53.1 years). The percent nighttime BP fall (%NBPF) was defined using ambulatory BP monitoring as a percent decrease in mean systolic BP in nighttime from daytime. All patients were divided into three groups: dipper (%NBPF ≥10), non-dipper (0 ≤ %NBPF < 10), and riser (%NBPF <0). Riser patients had the highest serum creatinine levels (dipper, 0.78 ± 0.20 mg/dl; non-dipper, 0.85 ± 0.21 mg/dl; riser, 0.99 ± 0.23 mg/dl; p = 0.006). In survival analysis, riser patients had the highest cumulative cardiac-related deaths (log-rank, p = 0.001), which was an independent predictor of cardiac-related deaths (hazard ratio, 12.6; 95% confidence interval, 1.76-253; p = 0.01). Multivariate analysis revealed that the norepinephrine level at 24-hour collected urine (24 h U-NE) and the serum creatinine level were independent determinants of %NBPF (adjusted R2 = 0.20; 24 h U-NE, p = 0.0001; serum creatinine, p = 0.04). The riser profile was associated with poor prognosis of NIDCM, which may reflect impaired sympathetic nervous system activity. Evaluating the circadian BP profile may be useful for risk stratification in NIDCM patients. © 2016 S. Karger AG, Basel.

  16. 75 FR 26091 - Safety Zone; Riser for DEEPWATER HORIZON at Mississippi Canyon 252 Outer Continental Shelf MODU...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-11

    ... establishing a safety zone around the riser for the DEEPWATER HORIZON, a Mobile Offshore Drilling Unit (MODU... Mexico in response to the sinking of the DEEPWATER HORIZON, a Mobile Offshore Drilling Unit (MODU), which.... 147.T08-849 to read as follows: Sec. 147.T08-849 DEEPWATER HORIZON Mobile Offshore Drilling Unit...

  17. Parent Participation within Community Center or In-Home Outreach Delivery Models of the Early Risers Conduct Problems Prevention Program

    ERIC Educational Resources Information Center

    Bloomquist, Michael L; August, Gerald J.; Lee, Susanne S.; Piehler, Timothy F.; Jensen, Marcia

    2012-01-01

    A variety of predictors of parent participation in prevention programming have been identified in past research, but few studies have investigated how those predictors may vary by implementation context. Patterns of parent participation were examined in the Early Risers Conduct Problems Prevention Program using two family-focused service delivery…

  18. Riser Pattern Is a Novel Predictor of Adverse Events in Heart Failure Patients With Preserved Ejection Fraction.

    PubMed

    Komori, Takahiro; Eguchi, Kazuo; Saito, Toshinobu; Hoshide, Satoshi; Kario, Kazuomi

    2017-01-25

    The cardiovascular prognosis of heart failure with preserved ejection fraction (HFpEF) has been shown to be similar to that of heart failure with reduced ejection fraction (HFrEF). It is unknown which factors predict cardiovascular outcome in HFpEF. We tested the hypothesis that the abnormal pattern of circadian blood pressure (BP) rhythm known as the riser BP pattern is associated with adverse outcomes in HFpEF.Methods and Results:We performed a prospective, observational cohort study of hospitalized HF patients who underwent ambulatory BP monitoring (ABPM). Five hundred and sixteen hospitalized HF patients (age, 69±13 years; male, n=321 [62%]; female, n=195 [38%]) were followed up for a median 20.9 months. The composite outcome consisting of all-cause mortality and cardiovascular events was observed in 220 patients. On Kaplan-Meier analysis, the riser BP pattern subgroup had a significantly higher incidence of the composite outcome than the other subgroups of HFpEF patients (HR, 3.01; 95% CI: 1.54-6.08, P<0.01), but not the HFrEF patients. The riser BP pattern was found to be a novel predictor of cardiovascular outcome in HFpEF patients.

  19. Influence of cross-sectional ratio of down comer to riser on the efficiency of liquid circulation in loop air lift bubble column

    NASA Astrophysics Data System (ADS)

    Yamamoto, Tatsumi; Kawasaki, Hiroyuki; Mori, Hidetoshi

    2017-11-01

    Loop type bubble columns have good performance of liquid circulation and mass transfer by airlift effect, where the liquid circulation time is an important measurable characteristic parameter. This parameter is affected by the column construction, the aspect ratio of the column, the cross-sectional area ratio of down comer to riser (R), and the superficial gas velocity in the riser (UGR). In this work, the mean gas holdup and the liquid circulation time (TC) have been measured in four types of loop airlift type bubble column: concentric tube internal loop airlift type, rectangular internal loop airlift type, external loop airlift type, external loop airlift with separator. Air and tap water were used as gas and liquid phase, respectively. The results have demonstrated that the mean gas holdup in riser increases in proportion to UGR, and that it in downcomer changes according to the geometric parameters of each bubble column. TC has been found to conform to an empirical equation which depends on UGR and the length of draft tube or division plate in the region of 0.33 < R < 1.

  20. The Relationship of an Ecological Model of Career Development to Authentic Learning. Research Institute on Secondary Education Reform (RISER) for Youth with Disabilities Brief.

    ERIC Educational Resources Information Center

    Collet-Klingenberg, Lana L.; Hanley-Maxwell, Cheryl; Stuart, Shannon

    This brief discusses how the Research Institute on Secondary Education Reform (RISER) for Youth with Disabilities model, Schools of Authentic Inclusive Learning (SAIL), and career development constructs and processes intersect. The brief provides an overview of SAIL, of authentic and inclusive learning, and of career development theory, while…

  1. Obseration of flow regime transition in CFB riser using an LDV

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yue, Paul C.; Mei, Joseph S.; Shadle, Lawrence J.

    2011-01-01

    The solids flow in a circulating fluidized bed (CFB) riser is often described to have a core-annular structure. For a given superficial gas velocity, at the initial introduction of solids into a riser a flow structure of dilute upflow regime exists. Continuing to increase the solids flow in the riser transitions the flow structure to the core-annular flow regime. However, with further increase of solids flow a condition is reached, depending on the superficial gas velocity, where all the solids across the riser cross section flow upwards, even those at the wall. When the solids flux, solids fraction and gasmore » velocity are relatively high, such a condition is described as the dense phase suspense upflow (DSU) regime. In this paper we report our observations of these flow regime transitions by using a laser Doppler velocimeter (LDV) to monitor the upward and downward particle flow velocities at and near the riser wall of the National Energy Technology Laboratory’s 30.4 centimeters diameter CFB cold flow model. The particles were high density polyethylene (PPE) spheres with a Sauter mean diameter of 861 micron and a density of 800 kg/m3. Three superficial gas velocities of 6.55 m/s, 10.67 m/s and 13.72 m/s were used in this study. For the case of superficial gas velocity 6.55 m/s, the experimental data show that the transition from dilute upflow to core-annular flow occurred when the solids flux was about 7 kg/m{sup 2}-s and the transition from core-annular flow to dense suspension upflow was about 147 kg/m{sup 2}-s. As the superficial gas velocity was increased to 10.67 m/s the corresponding flow regime transitions were at 34 kg/m{sup 2}-s and 205 kg/m{sup 2}-s, respectively. For the case of superficial gas velocity of 13.72 m/s the data showed no distinct transition of flow regimes. The particles were all upflow for the range of solids fluxes from 10 kg/m{sup 2}-s to 286 kg/m{sup 2}-s.« less

  2. Influence of drilling operations on drilling mud gas monitoring during IODP Exp. 338 and 348

    NASA Astrophysics Data System (ADS)

    Hammerschmidt, Sebastian; Toczko, Sean; Kubo, Yusuke; Wiersberg, Thomas; Fuchida, Shigeshi; Kopf, Achim; Hirose, Takehiro; Saffer, Demian; Tobin, Harold; Expedition 348 Scientists, the

    2014-05-01

    The history of scientific ocean drilling has developed some new techniques and technologies for drilling science, dynamic positioning being one of the most famous. However, while industry has developed newer tools and techniques, only some of these have been used in scientific ocean drilling. The introduction of riser-drilling, which recirculates the drilling mud and returns to the platform solids and gases from the formation, to the International Ocean Drilling Program (IODP) through the launch of the Japan Agency of Marine Earth-Science and Technology (JAMSTEC) riser-drilling vessel D/V Chikyu, has made some of these techniques available to science. IODP Expedition 319 (NanTroSEIZE Stage 2: riser/riserless observatory) was the first such attempt, and among the tools and techniques used was drilling mud gas analysis. While industry regularly conducts drilling mud gas logging for safety concerns and reservoir evaluation, science is more interested in other components (e.g He, 222Rn) that are beyond the scope of typical mud logging services. Drilling mud gas logging simply examines the gases released into the drilling mud as part of the drilling process; the bit breaks and grinds the formation, releasing any trapped gases. These then circulate within the "closed circuit" mud-flow back to the drilling rig, where a degasser extracts these gases and passes them on to a dedicated mud gas logging unit. The unit contains gas chromatographs, mass spectrometers, spectral analyzers, radon gas analyzers, and a methane carbon isotope analyzer. Data are collected and stored in a database, together with several drilling parameters (rate of penetration, mud density, etc.). This initial attempt was further refined during IODP Expeditions 337 (Deep Coalbed Biosphere off Shimokita), 338 (NanTroSEIZE Stage 3: NanTroSEIZE Plate Boundary Deep Riser 2) and finally 348 (NanTroSEIZE Stage 3: NanTroSEIZE Plate Boundary Deep Riser 3). Although still in its development stage for scientific application, this technique can provide a valuable suite of measurements to complement more traditional IODP shipboard measurements. Here we present unpublished data from IODP Expeditions 338 and 348, penetrating the Nankai Accretionary wedge to 3058.5 meters below seafloor. Increasing mud density decreased degasser efficiency, especially for higher hydrocarbons. Blurring of the relative variations in total gas by depth was observed, and confirmed with comparison to headspace gas concentrations from the cored interval. Theoretically, overpressured zones in the formation can be identified through C2/C3 ratios, but these ratios are highly affected by changing drilling parameters. Proper mud gas evaluations will need to carefully consider the effects of variable drilling parameters when designing experiments and interpreting the data.

  3. [Study of shear rate in modified airlift nitrifying bioreactor].

    PubMed

    Jin, Ren-cun; Zheng, Ping

    2006-06-01

    The characteristics of shear rate in an airlift nitrifying bioreactor and its influencing factors were studied. The results showed that the shear rate was different in different sections of the bioreactor. With inlet gas flowrate at 430 approximately 2700 L x h(-1), the overall shear rate was (0.702 approximately 3.13) x 10(5) s(-1), shear rate in riser was (1.07 approximately 31.3) x 10(5) s(-1) and in gas-liquid separator was (1.12 approximately 25.0) x 10(5) s(-1), respectively. It indicates that the highest shear rates prevailed in the riser part of bioreactor. The operational variables and the bioreactor configurations exerted a significant influence on the shear level of the bioreactor. When inlet gas flowrate was raised from 1300 to 2700 L x h(-1), shear rate in riser and separator ascended first and then descended subsequently. The diameter of draft tube (d) was negatively correlated with shear rate. When the draft tube with diameter of 5.5 cm was installed, the shear rates in riser, separator and overall shear rate were 85.5%, 82.3% and 80.6%, respectively less as compared with that with diameter of 4.0 cm. The number of static mixers (N) was positively correlated with the shear rate. When d was set at 4.0 cm, with N of 10 and 39, the shear rates in riser were 6.14 and 7.97 times higher respectively, than that of conventional bioreactor. The ratio of maximum local shear rate to overall shear rate was 3.68 approximately 7.66, and the homogeneity of the shear field in airlift bioreactors could be improved if d and N were set at 5.5 cm and 10 approximately 13, respectively.

  4. Short sleep duration as an independent predictor of cardiovascular events in Japanese patients with hypertension.

    PubMed

    Eguchi, Kazuo; Pickering, Thomas G; Schwartz, Joseph E; Hoshide, Satoshi; Ishikawa, Joji; Ishikawa, Shizukiyo; Shimada, Kazuyuki; Kario, Kazuomi

    2008-11-10

    It is not known whether short duration of sleep is a predictor of future cardiovascular events in patients with hypertension. To test the hypothesis that short duration of sleep is independently associated with incident cardiovascular diseases (CVD), we performed ambulatory blood pressure (BP) monitoring in 1255 subjects with hypertension (mean [SD] age, 70.4 [9.9] years) and followed them for a mean period of 50 (23) months. Short sleep duration was defined as less than 7.5 hours (20th percentile). Multivariable Cox hazard models predicting CVD events were used to estimate the adjusted hazard ratio and 95% confidence interval (CI) for short sleep duration. A riser pattern was defined when mean nighttime systolic BP exceeded daytime systolic BP. The end point was a cardiovascular event: stroke, fatal or nonfatal myocardial infarction (MI), and sudden cardiac death. In multivariable analyses, short duration of sleep (<7.5 hours) was associated with incident CVD (hazard ratio [HR], 1.68; 95% CI, 1.06-2.66; P = .03). A synergistic interaction was observed between short sleep duration and the riser pattern (P = .09). When subjects were classified according to their sleep time and a riser vs nonriser pattern, the group with shorter sleep duration plus the riser pattern had a substantially and significantly higher incidence of CVD than the group with predominant normal sleep duration plus the nonriser pattern (HR, 4.43; 95% CI, 2.09-9.39; P < .001), independent of covariates. Short duration of sleep is associated with incident CVD risk and the combination of the riser pattern and short duration of sleep that is most strongly predictive of future CVD, independent of ambulatory BP levels. Physicians should inquire about sleep duration in the risk assessment of patients with hypertension.

  5. Proximal tibial fracture following anterior cruciate ligament reconstruction surgery: a biomechanical analysis of the tibial tunnel as a stress riser.

    PubMed

    Aldebeyan, Wassim; Liddell, Antony; Steffen, Thomas; Beckman, Lorne; Martineau, Paul A

    2017-08-01

    This is the first biomechanical study to examine the potential stress riser effect of the tibial tunnel or tunnels after ACL reconstruction surgery. In keeping with literature, the primary hypothesis tested in this study was that the tibial tunnel acts as a stress riser for fracture propagation. Secondary hypotheses were that the stress riser effect increases with the size of the tunnel (8 vs. 10 mm), the orientation of the tunnel [standard (STT) vs. modified transtibial (MTT)], and with the number of tunnels (1 vs. 2). Tibial tunnels simulating both single bundle hamstring graft (8 mm) and bone-patellar tendon-bone graft (10 mm) either STT or MTT position, as well as tunnels simulating double bundle (DB) ACL reconstruction (7, 6 mm), were drilled in fourth-generation saw bones. These five experimental groups and a control group consisting of native saw bones without tunnels were loaded to failure on a Materials Testing System to simulate tibial plateau fracture. There were no statistically significant differences in peak load to failure between any of the groups, including the control group. The fracture occurred through the tibial tunnel in 100 % of the MTT tunnels (8 and 10 mm) and 80 % of the DB tunnels specimens; however, the fractures never (0 %) occurred through the tibial tunnel of the standard tunnels (8 or 10 mm) (P = 0.032). In the biomechanical model, the tibial tunnel does not appear to be a stress riser for fracture propagation, despite suggestions to the contrary in the literature. Use of a standard, more vertical tunnel decreases the risk of ACL graft compromise in the event of a fracture. This may help to inform surgical decision making on ACL reconstruction technique.

  6. A modified multi-objective particle swarm optimization approach and its application to the design of a deepwater composite riser

    NASA Astrophysics Data System (ADS)

    Zheng, Y.; Chen, J.

    2017-09-01

    A modified multi-objective particle swarm optimization method is proposed for obtaining Pareto-optimal solutions effectively. Different from traditional multi-objective particle swarm optimization methods, Kriging meta-models and the trapezoid index are introduced and integrated with the traditional one. Kriging meta-models are built to match expensive or black-box functions. By applying Kriging meta-models, function evaluation numbers are decreased and the boundary Pareto-optimal solutions are identified rapidly. For bi-objective optimization problems, the trapezoid index is calculated as the sum of the trapezoid's area formed by the Pareto-optimal solutions and one objective axis. It can serve as a measure whether the Pareto-optimal solutions converge to the Pareto front. Illustrative examples indicate that to obtain Pareto-optimal solutions, the method proposed needs fewer function evaluations than the traditional multi-objective particle swarm optimization method and the non-dominated sorting genetic algorithm II method, and both the accuracy and the computational efficiency are improved. The proposed method is also applied to the design of a deepwater composite riser example in which the structural performances are calculated by numerical analysis. The design aim was to enhance the tension strength and minimize the cost. Under the buckling constraint, the optimal trade-off of tensile strength and material volume is obtained. The results demonstrated that the proposed method can effectively deal with multi-objective optimizations with black-box functions.

  7. Phase shift method to estimate solids circulation rate in circulating fluidized beds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ludlow, James Christopher; Panday, Rupen; Shadle, Lawrence J.

    2013-01-01

    While solids circulation rate is a critical design and control parameter in circulating fluidized bed (CFB) reactor systems, there are no available techniques to measure it directly at conditions of industrial interest. Cold flow tests have been conducted at NETL in an industrial scale CFB unit where the solids flow has been the topic of research in order to develop an independent method which could be applied to CFBs operating under the erosive and corrosive high temperatures and pressures of a coal fired boiler or gasifier. The dynamic responses of the CFB loop to modest modulated aeration flows in themore » return leg or standpipe were imposed to establish a periodic response in the unit without causing upset in the process performance. The resulting periodic behavior could then be analyzed with a dynamic model and the average solids circulation rate could be established. This method was applied to the CFB unit operated under a wide range of operating conditions including fast fluidization, core annular flow, dilute and dense transport, and dense suspension upflow. In addition, the system was operated in both low and high total solids inventories to explore the influence of inventory limiting cases on the estimated results. The technique was able to estimate the solids circulation rate for all transport circulating fluidized beds when operating above upper transport velocity, U{sub tr2}. For CFB operating in the fast fluidized bed regime (i.e., U{sub g}< U{sub tr2}), the phase shift technique was not successful. The riser pressure drop becomes independent of the solids circulation rate and the mass flow rate out of the riser does not show modulated behavior even when the riser pressure drop does.« less

  8. Blood pressure circadian rhythms and adverse outcomes in type 2 diabetes patients diagnosed with orthostatic hypotension.

    PubMed

    Chang, Jing; Hou, Yuan-Ping; Wu, Jin-Ling; Fang, Xiang-Yang; Li, Sheng-Li; Liu, Miao-Bing; Sun, Qian-Mei

    2018-03-01

    Patients with diabetes frequently develop orthostatic hypotension (OH). The present study was designed to examine the relationship of blood pressure (BP) circadian rhythms and outcomes in diabetes with OH. In the present study, 173 inpatients with type 2 diabetes were enrolled. Patients were divided into an OH group and a non-OH group according to the BP changes detected in the supine and standing position. Then, 24-h ambulatory BP was monitored. Patients were followed up for an average of 45 ± 10 months post-discharge. Outcomes - death and major adverse cardiac and cerebrovascular events, including heart failure, myocardial infarction and stroke - were recorded. There were 61 patients (35.26%) in the OH group and 112 patients (64.74%) in the non-OH group. In the OH group, the night-time systolic BP and night-time diastolic BP were higher, the blood BP rhythms were predominantly of the riser type (67.21%). OH was as an independent marker of riser type circadian rhythm (adjusted odds ratio 4.532, 95% confidence interval 2.579-7.966). In the OH group, the incidence rates of mortality, and major adverse cardiac and cerebrovascular events were increased significantly compared with those in the non-OH group (11.48 vs 2.68%, P = 0.014; 37.70 vs 8.93%, P < 0.01). In patients who had type 2 diabetes diagnosed with OH, the BP circadian rhythm usually showed riser patterns, and they had increased rates of mortality, and major adverse cardiac and cerebrovascular events. © 2017 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  9. FY16 Progress Report on Test Results In Support Of Integrated EPP and SMT Design Methods Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yanli; Jetter, Robert I.; Sham, T. -L.

    2016-08-08

    The proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology consists of incorporating an SMT data-based approach for creep-fatigue damage evaluation into the EPP methodology to avoid using the creep-fatigue interaction diagram (the D diagram) and to minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed code rules and to verify their applicability, a series of thermomechanical tests have been initiated. This report presents the recent test results for Type 2 SMT specimens on Alloy 617, Pressurization SMT on Alloy 617, Type 1 SMT on Gr. 91, and two-barmore » thermal ratcheting test results on Alloy 617 with a new thermal loading profile.« less

  10. The effects of choir spacing and choir formation on the tuning accuracy and intonation tendencies of a mixed choir

    NASA Astrophysics Data System (ADS)

    Daugherty, James F.

    2005-09-01

    The tuning accuracy and intonation tendencies of a high school mixed choir (N=46) were measured from digital recordings obtained as the ensemble performed an a cappella motet under concert conditions in N=3 singer spacing configurations (close, lateral, circumambient) and N=2 choir formations (sectional and mixed). Methods of analysis were modeled on Howard's (2004) pitch-based measurements of the tuning accuracy of crowds of football fans. Results were discussed in terms of (a) previous studies on choir spacing (Daugherty, 1999, 2003) and self-to-other singer ratios (Ternstrm, 1995, 1999); (b) contributions of choir spacing to vocal/choral pedagogy; and (c) potential ramifications for the design and use of auditoria and portable standing risers for choral performances.

  11. Hydrodynamic optimization of membrane bioreactor by horizontal geometry modification using computational fluid dynamics.

    PubMed

    Yan, Xiaoxu; Wu, Qing; Sun, Jianyu; Liang, Peng; Zhang, Xiaoyuan; Xiao, Kang; Huang, Xia

    2016-01-01

    Geometry property would affect the hydrodynamics of membrane bioreactor (MBR), which was directly related to membrane fouling rate. The simulation of a bench-scale MBR by computational fluid dynamics (CFD) showed that the shear stress on membrane surface could be elevated by 74% if the membrane was sandwiched between two baffles (baffled MBR), compared with that without baffles (unbaffled MBR). The effects of horizontal geometry characteristics of a bench-scale membrane tank were discussed (riser length index Lr, downcomer length index Ld, tank width index Wt). Simulation results indicated that the average cross flow of the riser was negatively correlated to the ratio of riser and downcomer cross-sectional area. A relatively small tank width would also be preferable in promoting shear stress on membrane surface. The optimized MBR had a shear elevation of 21.3-91.4% compared with unbaffled MBR under same aeration intensity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Real World Software Engineering

    DTIC Science & Technology

    1994-07-15

    Corvision Cortex Corporation Daisys S /Cubed, Inc. Design/IDF & CPN Meta Software Corp. 22 EasyCase Professional Evergreen CASE Tools 8522 150th 4th Ave NE...Final RSUoTL 28 Sep 92-31 May 94 4. TITLE AND SUBTITLE S . FUNDING NUMBERS Real World Software Engineering 6. AUTHOR( S ) Donald Gotterbarn Robert Riser . a...nin• Sm-i t’h 7. PERFORMING ORGANIZATION NAME( S ) AND AOORESS(ES1 8. PERFORMING ORGANIZATION REPORT NUMBER East Tennessee State University Department

  13. New Standard Weir Design for Dredged Material Management Area, Jacksonville District

    DTIC Science & Technology

    2014-08-01

    dock access, Bartram Island Cell B2, Jacksonville, Florida. Report Documentation Page Form ApprovedOMB No. 0704-0188 Public reporting burden for...Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 ERDC/TN DOTS-14-01 August 2014 2 US Army Corps of Engineers • Engineer Research...and through the riser stack of weir boards. This requires secondary sealing measures in the form of plastic sheeting, geotextiles, and/or burlap

  14. Faulted terrace risers place new constraints on the late Quaternary slip rate for the central Altyn Tagh fault, northwest Tibet

    USGS Publications Warehouse

    Gold, R.D.; Cowgill, E.; Arrowsmith, J.R.; Chen, X.; Sharp, W.D.; Cooper, K.M.; Wang, X.-F.

    2011-01-01

    The active, left-lateral Altyn Tagh fault defines the northwestern margin of the Tibetan Plateau in western China. To clarify late Quaternary temporal and spatial variations in slip rate along the central portion of this fault system (85??-90??E), we have more than doubled the number of dated offset markers along the central Altyn Tagh fault. In particular, we determined offset-age relations for seven left-laterally faulted terrace risers at three sites (Kelutelage, Yukuang, and Keke Qiapu) spanning a 140-km-long fault reach by integrating surficial geologic mapping, topographic surveys (total station and tripod-light detection and ranging [T-LiDAR]), and geochronology (radiocarbon dating of organic samples, 230Th/U dating of pedogenic carbonate coatings on buried clasts, and terrestrial cosmogenic radionuclide exposure age dating applied to quartz-rich gravels). At Kelutelage, which is the westernmost site (37.72??N, 86.67??E), two faulted terrace risers are offset 58 ?? 3 m and 48 ?? 4 m, and formed at 6.2-6.1 ka and 5.9-3.7 ka, respectively. At the Yukuang site (38.00??N, 87.87??E), four faulted terrace risers are offset 92 ?? 12 m, 68 ?? 6 m, 55 ?? 13 m, and 59 ?? 9 m and formed at 24.2-9.5 ka, 6.4-5.0 ka, 5.1-3.9 ka, and 24.2-6.4 ka, respectively. At the easternmost site, Keke Qiapu (38.08??N, 88.12??E), a faulted terrace riser is offset 33 ?? 6 m and has an age of 17.1-2.2 ka. The displacement-age relationships derived from these markers can be satisfied by an approximately uniform slip rate of 8-12 mm/yr. However, additional analysis is required to test how much temporal variability in slip rate is permitted by this data set. ?? 2011 Geological Society of America.

  15. Tank 241-Z-361 Sludge Retrieval and Treatment Alternatives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    HAMPTON, B.K.

    2000-05-24

    The Plutonium Finishing Plant (PFP) Tank 241-Z-361 (Z-361) contains legacy sludge resulting from waste discharges from past missions at PFP. A sketch of the tank is shown in Figure 1. In this view various risers and penetrations are shown along with the sludge level depicted by the horizontal line halfway up the tank, and the ground level depicted by the horizontal line above the tank. The HEPA filter installed for breathing is also shown on one of the risers.

  16. Method and apparatus for production of subsea hydrocarbon formations

    DOEpatents

    Blandford, Joseph W.

    1994-01-01

    A well tender system for controlling, separating, storing and offloading well fluids produced from subsea hydrocarbon formations. The system comprises a vertically aligned series of tethered cylindrical tanks which are torsionally stabilized by flexible catenary production riser and export riser bundles, and serviced by separate catenary pipe bundles. Piles are secured to the seabed, each pile assembly being pivotally connected to a lower rigid tendon, which is in turn connected to tendons arranged about the periphery of the interconnected cylindrical tanks.

  17. Method and apparatus for production of subsea hydrocarbon formations

    DOEpatents

    Blandford, Joseph W.

    1992-01-01

    A well tender system for controlling, separating, storing and offloading well fluids produced from subsea hydrocarbon formations. The system comprises a vertically aligned series of tethered cylindrical tanks which are torsionally stabilized by flexible catenary production riser and expert riser bundles, and serviced by separate catenary pipe bundles. Piles are secured to the seabed, each pile assembly being pivotally connected to a lower rigid tendon, which is in turn connected to tendons arranged about the periphery of the interconnected cylindrical tanks.

  18. Fleet Mooring Underwater Inspection Report La Maddalena, Italy.

    DTIC Science & Technology

    1981-12-01

    Peg Top mooring buoys at the bow at the NATO Naval Facility, St. Stefano , Sardinia, Italy. The ship using the mooring is moored at the stern to the...LAT: NSO LA MADDALENA NORTH RISER/MED MOOR LON:SANTO STEFANO ,ISardinia, Italy ii DATE DIVERS U 1WATER DEPTH SUPERVISOR INITIALS 5. INSPECTION 18-25 Sep...0) 0 蟙 W. .-. MOORING INSPECTION REPORT Page 3 of 3 1. FACILITY 2. MOORING NO. 13. TYPE/CLASSMOORING 4. LAT.RISER/MD MOOR SANTO STEFANO , NSO LA

  19. Alternate retrieval technology demonstrations program - test report (ARD Environmental, Inc.)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berglin, E.J.

    A prototype vehicle, control system, and waste and water scavenging system were designed and fabricated with essentially the full capabilities of the vehicle system proposed by ARD Environmental. A test tank mockup, including riser and decontamination chamber were designed and fabricated, and approximately 830 cubic feet of six varieties of waste simulants poured. The tests were performed by ARD Environmental personnel at its site in Laurel, Maryland, from 4/22/97 through 5/2/97. The capabilities tested were deployment and retrieval, extended mobility and productivity, the ability to operate the system using video viewing only, retrieval after simulated failure, and retrieval and decontamination.more » Testing commenced with deployment of the vehicle into the tank. Deployment was accomplished using a crane and auxiliary winch to position the vehicle and lower it through the decontamination chamber, into the 36`` diameter x 6` high riser, and touch down on the waste field in the tank. The initial mobility tests were conducted immediately after deployment, prior to sluicing, as the waste field exhibited the greatest amount of variation at this time. This test demonstrated the ability of the vehicle to maneuver over the simulated waste field, and the ability of the operator to work with only video viewing available. In addition, the ability of the vehicle to right itself after being turned on its side was demonstrated. The production rate was evaluated daily through the testing period by measuring the surface and estimating the amount of material removed. The test demonstrated the ability of the vehicle to reduce the waste surface using 400 psi (nominal) water jets, scavenge water and material from the work area, and move to any location, even in the relatively confined space of the 20` diameter test tank. In addition, the ability to sluice to a remote scavenging module was demonstrated. The failure mode test demonstrated the ability to retrieve a stuck vehicle by pulling on the tether, even if the vehicle wheels were locked or the vehicle was on its side. Line pull required to retrieve the vehicle was measured, and side load on the riser calculated from the line pull and line angles. Finally, the decontamination test demonstrated the ability to effectively clean the umbilical and vehicle. The issues addressed and resolved during the testing were: Feasibility of deploying a vehicle- based system, mobility, production rate and limitation of water in the tank during sluicing, mining strategy, operator efficiency, vehicle recovery, and decontamination. Water usage and waste removal rates were used to estimate the time and water usage requirements for cleaning a Hanford SST.« less

  20. Effect of catalyst additives on the production of biofuels from palm oil cracking in a transport riser reactor.

    PubMed

    Chew, Thiam Leng; Bhatia, Subhash

    2009-05-01

    Catalytic cracking of crude palm oil (CPO) and used palm oil (UPO) were studied in a transport riser reactor for the production of biofuels at a reaction temperature of 450 degrees C, with residence time of 20s and catalyst-to-oil ratio (CTO) of 5 gg(-1). The effect of HZSM-5 (different Si/Al ratios), beta zeolite, SBA-15 and AlSBA-15 were studied as physically mixed additives with cracking catalyst Rare earth-Y (REY). REY catalyst alone gave 75.8 wt% conversion with 34.5 wt% of gasoline fraction yield using CPO, whereas with UPO, the conversion was 70.9 wt% with gasoline fraction yield of 33.0 wt%. HZSM-5, beta zeolite, SBA-15 and AlSBA-15 as additives with REY increased the conversion and the yield of organic liquid product. The transport riser reactor can be used for the continuous production of biofuels from cracking of CPO and UPO over REY catalyst.

  1. Energy absorption device for shock loading

    NASA Astrophysics Data System (ADS)

    Howard, C. D.; Lagrange, Donald E.; Beatty, David A.; Littman, David C.

    1995-02-01

    A shock energy absorbing device provides shock protection for the riser line employed to attach an aerodynamic deceleration device to a primary body during deployment of the system into an airstream. During deployment, for example, by dropping an unopened parachute and attached load or by rocket delivery of the unopened parachute and attached load, the parachute is made to open at a desired altitude whereupon very large shock tension forces are generated which are applied to the line. In order to protect the line from failing under these forces and to reduce the requirement for a bulky, heavy line, a shock absorber is provided in the form of a block having one or more breakable web portions formed therein and through which the riser line is threaded. Upon deployment of the system into an airstream, the shock tension forces operate to fracture some or all of the breakable web portions thereby dissipating the shock energy generated during deployment and protecting the riser line from failure.

  2. Transient Characterization of Type B Particles in a Transport Riser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shadle, L.J.; Monazam, E.R.; Mei, J.S.

    2007-01-01

    Simple and rapid dynamic tests were used to evaluate fluid dynamic behavior of granular materials in the transport regime. Particles with densities ranging from 189 to 2,500 kg/m3 and Sauter mean size from 61 to 812 μm were tested in a 0.305 m diameter, 15.5 m height circulating fluidized bed (CFB) riser. The transient tests involved the abrupt stoppage of solids flow for each granular material over a wide range gas flow rates. The riser emptying time was linearly related to the Froude number in each of three different operating regimes. The flow structure along the height of the risermore » followed a distinct pattern as tracked through incremental pressures. These results are discussed to better understand the transformations that take place when operating over various regimes. During the transients the particle size distribution was measured. The effects of pressure, particle size, and density on test performance are also presented.« less

  3. Nuclear reactor pressure vessel support system

    DOEpatents

    Sepelak, George R.

    1978-01-01

    A support system for nuclear reactor pressure vessels which can withstand all possible combinations of stresses caused by a postulated core disrupting accident during reactor operation. The nuclear reactor pressure vessel is provided with a flange around the upper periphery thereof, and the flange includes an annular vertical extension formed integral therewith. A support ring is positioned atop of the support ledge and the flange vertical extension, and is bolted to both members. The plug riser is secured to the flange vertical extension and to the top of a radially outwardly extension of the rotatable plug. This system eliminates one joint through which fluids contained in the vessel could escape by making the fluid flow path through the joint between the flange and the support ring follow the same path through which fluid could escape through the plug risers. In this manner, the sealing means to prohibit the escape of contained fluids through the plug risers can also prohibit the escape of contained fluid through the securing joint.

  4. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  5. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  6. 36 CFR Appendix B to Part 1234 - Alternative Certified Fire-Safety Detection and Suppression System(s)

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...

  7. A computational and theoretical analysis of falling frequency VLF emissions

    NASA Astrophysics Data System (ADS)

    Nunn, David; Omura, Yoshiharu

    2012-08-01

    Recently much progress has been made in the simulation and theoretical understanding of rising frequency triggered emissions and rising chorus. Both PIC and Vlasov VHS codes produce risers in the region downstream from the equator toward which the VLF waves are traveling. The VHS code only produces fallers or downward hooks with difficulty due to the coherent nature of wave particle interaction across the equator. With the VHS code we now confine the interaction region to be the region upstream from the equator, where inhomogeneity factor S is positive. This suppresses correlated wave particle interaction effects across the equator and the tendency of the code to trigger risers, and permits the formation of a proper falling tone generation region. The VHS code now easily and reproducibly triggers falling tones. The evolution of resonant particle current JE in space and time shows a generation point at -5224 km and the wavefield undergoes amplification of some 25 dB in traversing the nonlinear generation region. The current component parallel to wave magnetic field (JB) is positive, whereas it is negative for risers. The resonant particle trap shows an enhanced distribution function or `hill', whereas risers have a `hole'. According to recent theory (Omura et al., 2008, 2009) sweeping frequency is due primarily to the advective term. The nonlinear frequency shift term is now negative (˜-12 Hz) and the sweep rate of -800 Hz/s is approximately nonlinear frequency shift divided by TN, the transition time, of the order of a trapping time.

  8. OTEC Cold Water Pipe-Platform Subsystem Dynamic Interaction Validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Varley, Robert; Halkyard, John; Johnson, Peter

    A commercial floating 100-megawatt (MW) ocean thermal energy conversion (OTEC) power plant will require a cold water pipe (CWP) with a diameter of 10-meter (m) and length of up to 1,000 m. The mass of the cold water pipe, including entrained water, can exceed the mass of the platform supporting it. The offshore industry uses software-modeling tools to develop platform and riser (pipe) designs to survive the offshore environment. These tools are typically validated by scale model tests in facilities able to replicate real at-sea meteorological and ocean (metocean) conditions to provide the understanding and confidence to proceed to finalmore » design and full-scale fabrication. However, today’s offshore platforms (similar to and usually larger than those needed for OTEC applications) incorporate risers (or pipes) with diameters well under one meter. Secondly, the preferred construction method for large diameter OTEC CWPs is the use of composite materials, primarily a form of fiber-reinforced plastic (FRP). The use of these material results in relatively low pipe stiffness and large strains compared to steel construction. These factors suggest the need for further validation of offshore industry software tools. The purpose of this project was to validate the ability to model numerically the dynamic interaction between a large cold water-filled fiberglass pipe and a floating OTEC platform excited by metocean weather conditions using measurements from a scale model tested in an ocean basin test facility.« less

  9. Development of a Post-Installed Deepwater Monitoring System

    NASA Technical Reports Server (NTRS)

    Seaman, C.; Brower, D. V.; Tang, H.; Le, S.

    2015-01-01

    A monitoring system that can be deployed on already existing deep water risers and flowlines has been developed. This paper describes the design concepts and testing that was performed in developing the monitoring system. A major challenge of a post-installed instrumentation system is to ensure adequate coupling is achieved between the instruments and the riser or flowline. This work investigates the sensor coupling for pipelines that are suspended in both the water column (from topside platform to the seabed) and for those that are located directly on the seabed. These different environments have resulted in two sensor attachment methods: (1) subsea adhesive sensor clamp design and (2) a friction surface sensor attachment method. This paper presents the adhesive attachment method. The monitoring elements consist of fiber optic sensors that are encased in a polyurethane clamp. With a subsea adhesive, the clamp can be installed by divers in shallow depths or by use of an ROV for deeper applications. The NASA Johnson Space Center was initially involved in the selection and testing of subsea adhesives. It was determined that up to 75 percent of the bonding strength could be achieved with the adhesive from optimal dry bonding versus bonding in submerged sea water environments. The next phase of the study involved the design, fabrication, and testing of several prototype clamps that contained the fiber optic sensors. A mold was produced by NASA using 3-D printing methods that allowed the fabrication of subscale test articles that would accommodate 4-inch and 8-inch diameter pipes. The clamps were installed with adhesive in a "wet" environment on the pipe test articles and tested in the NASA Structures Test Laboratory. The tension/compression and bending tests showed that the prototype sensor clamps achieved good coupling, and could provide high quality strain measurement for active monitoring.

  10. Experimental Plan for Crystal Accumulation Studies in the WTP Melter Riser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, D.; Fowley, M.

    2015-04-28

    This experimental plan defines crystal settling experiments to be in support of the U.S. Department of Energy – Office of River Protection crystal tolerant glass program. The road map for development of crystal-tolerant high level waste glasses recommends that fluid dynamic modeling be used to better understand the accumulation of crystals in the melter riser and mechanisms of removal. A full-scale version of the Hanford Waste Treatment and Immobilization Plant (WTP) melter riser constructed with transparent material will be used to provide data in support of model development. The system will also provide a platform to demonstrate mitigation or recoverymore » strategies in off-normal events where crystal accumulation impedes melter operation. Test conditions and material properties will be chosen to provide results over a variety of parameters, which can be used to guide validation experiments with the Research Scale Melter at the Pacific Northwest National Laboratory, and that will ultimately lead to the development of a process control strategy for the full scale WTP melter. The experiments described in this plan are divided into two phases. Bench scale tests will be used in Phase 1 (using the appropriate solid and fluid simulants to represent molten glass and spinel crystals) to verify the detection methods and analytical measurements prior to their use in a larger scale system. In Phase 2, a full scale, room temperature mockup of the WTP melter riser will be fabricated. The mockup will provide dynamic measurements of flow conditions, including resistance to pouring, as well as allow visual observation of crystal accumulation behavior.« less

  11. New Holocene Slip-rate Sites Along the Mojave San Andreas Fault Near Palmdale, CA

    NASA Astrophysics Data System (ADS)

    Young, E. K.; Cowgill, E.; Scharer, K. M.

    2016-12-01

    The slip rate for the Mojave San Andreas fault (MSAF) is poorly known: the long-term ( 413ky) geologic rate is as high as 37mm/yr [1] while the geodetic slip rate is as low as 15mm/yr [2]. To determine the Holocene-average rate for the MSAF, we investigated several offset landforms near Palmdale, CA using detailed surficial mapping and 14C analyses of charcoal collected from hand-dug excavations. Site X-12 preserves two offset markers sourced from a north-flowing catchment south of the fault. One is a terrace riser cut into older alluvium that is abutted by the eastern margin of a Qf3 fan and is displaced by 75 m. Offset of the riser and the alluvium generated a north-facing fault-scarp that was eroded to form a small fan on top of the eastern margin of the Qf3 fan. The second offset is a beheaded channel that is incised into the Qf3 fan north of the fault and is displaced 50m, and thus formed after the riser was offset by 25m. To date these landforms we opened 5 excavations at the site, with emphasis on the beheaded channel. Dates from within the Qf3 fan south/upstream of the fault and abandoned bedload in the beheaded channel give maximum and minimum ages for the channel incision of 1500calBP and 600calBP, respectively, implying a rate ≥33mm/yr. Future work seeks to date post-abandonment channel-fill deposits and the upper and lower bounds on the terrace riser. At a second site, Ranch Center, a north-flowing stream cut across a shutter ridge north of the fault and was then offset and deflected 80m before cutting a new channel across the fault. Future work here seeks to date the bases of the alluvial fans deposited by the abandoned and active channels to obtain maximum and minimum ages for the 80 m offset, respectively. Rates from these sites should help to better define the Holocene slip rate on the MSAF. 1) Matmon et al., 2005, GSAB. v. 117 p. 795 2) Becker et al., 2005, Geoph.. J. Int., v. 160 p. 634

  12. Apparatus and methods for regeneration of precipitating solvent

    DOEpatents

    Liu, Guohai; Vimalchand, Pannalal; Peng, Wan Wang; Bonsu, Alexander

    2015-08-25

    A regenerator that can handle rich loaded chemical solvent containing precipitated absorption reaction products is disclosed. The invention is particularly suitable for separating CO.sub.2 from large gas streams that are typical of power plant processes. The internally circulating liquid stream in the regenerator (ICLS regenerator) rapidly heats-up the in-coming rich solvent stream in a downcomer standpipe as well as decreases the overall concentration of CO.sub.2 in the mixed stream. Both these actions lead to dissolution of precipitates. Any remaining precipitate further dissolves as heat is transferred to the mixed solution with an inverted bayonet tube heat exchanger in the riser portion of the regenerator. The evolving CO.sub.2 bubbles in the riser portion of the regenerator lead to substantial gas hold-up and the large density difference between the solutions in the downcomer standpipe and riser portions promotes internal circulation of the liquid stream in the regenerator. As minor amounts of solvent components present in the exit gas stream are condensed and returned back to the regenerator, pure CO.sub.2 gas stream exits the disclosed regenerator and condenser system.

  13. Effect of particle size distribution on the hydrodynamics of dense CFB risers

    NASA Astrophysics Data System (ADS)

    Bakshi, Akhilesh; Khanna, Samir; Venuturumilli, Raj; Altantzis, Christos; Ghoniem, Ahmed

    2015-11-01

    Circulating Fluidized Beds (CFB) are favorable in the energy and chemical industries, due to their high efficiency. While accurate hydrodynamic modeling is essential for optimizing performance, most CFB riser simulations are performed assuming equally-sized solid particles, owing to limited computational resources. Even though this approach yields reasonable predictions, it neglects commonly observed experimental findings suggesting the strong effect of particle size distribution (psd) on the hydrodynamics and chemical conversion. Thus, this study is focused on the inclusion of discrete particle sizes to represent the psd and its effect on fluidization via 2D numerical simulations. The particle sizes and corresponding mass fluxes are obtained using experimental data in dense CFB riser while the modeling framework is described in Bakshi et al 2015. Simulations are conducted at two scales: (a) fine grid to resolve heterogeneous structures and (b) coarse grid using EMMS sub-grid modifications. Using suitable metrics which capture bed dynamics, this study provides insights into segregation and mixing of particles as well as highlights need for improved sub-grid models.

  14. CFD Modelling of Particle Mixtures in a 2D CFB

    NASA Astrophysics Data System (ADS)

    Seppälä, M.; Kallio, S.

    The capability of Fluent 6.2.16 to simulate particle mixtures in a laboratory scale 2D circulating fluidized bed (CFB) unit has been tested. In the simulations, the solids were described as one or two particle phases. The loading ratio of small to large particles, particle diameters and the gas inflow velocity were varied. The 40 cm wide and 3 m high 2D CFB was modeled using a grid with 31080 cells. The outflow of particles at the top of the CFB was monitored and emanated particles were fed back to the riser through a return duct. The paper presents the segregation patterns of the particle phases obtained from the simulations. When the fraction of large particles was 50% or larger, large particles segregated, as expected, to the wall regions and to the bottom part of the riser. However, when the fraction of large particles was 10%, an excess of large particles was found in the upper half of the riser. The explanation for this unexpected phenomenon was found in the distribution of the large particles between the slow clusters and the faster moving lean suspension.

  15. Predictive Model for Particle Residence Time Distributions in Riser Reactors. Part 1: Model Development and Validation

    DOE PAGES

    Foust, Thomas D.; Ziegler, Jack L.; Pannala, Sreekanth; ...

    2017-02-28

    Here in this computational study, we model the mixing of biomass pyrolysis vapor with solid catalyst in circulating riser reactors with a focus on the determination of solid catalyst residence time distributions (RTDs). A comprehensive set of 2D and 3D simulations were conducted for a pilot-scale riser using the Eulerian-Eulerian two-fluid modeling framework with and without sub-grid-scale models for the gas-solids interaction. A validation test case was also simulated and compared to experiments, showing agreement in the pressure gradient and RTD mean and spread. For simulation cases, it was found that for accurate RTD prediction, the Johnson and Jackson partialmore » slip solids boundary condition was required for all models and a sub-grid model is useful so that ultra high resolutions grids that are very computationally intensive are not required. Finally, we discovered a 2/3 scaling relation for the RTD mean and spread when comparing resolved 2D simulations to validated unresolved 3D sub-grid-scale model simulations.« less

  16. High-Resolution Simulations of Gas-Solids Jet Penetration Into a High Density Riser Flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Tingwen

    2011-05-01

    High-resolution simulations of a gas-solids jet in a 0.3 m diameter and 15.9 m tall circulating fluidized bed (CFB) riser were conducted with the open source software-MFIX. In the numerical simulations, both gas and solids injected through a 1.6 cm diameter radial-directed tube 4.3 m above the bottom distributor were tracked as tracers, which enable the analysis of the characteristics of a two-phase jet. Two jetting gas velocities of 16.6 and 37.2 m/s were studied with the other operating conditions fixed. Reasonable flow hydrodynamics with respect to overall pressure drop, voidage, and solids velocity distributions were predicted. Due to themore » different dynamic responses of gas and particles to the crossflow, a significant separation of gas and solids within the jet region was predicted for both cases. In addition, the jet characteristics based on tracer concentration and tracer mass fraction profiles at different downstream levels are discussed. Overall, the numerical predictions compare favorably to the experimental measurements made at NETL.« less

  17. Nonlinear Analysis of a Bolted Marine Riser Connector Using NASTRAN Substructuring

    NASA Technical Reports Server (NTRS)

    Fox, G. L.

    1984-01-01

    Results of an investigation of the behavior of a bolted, flange type marine riser connector is reported. The method used to account for the nonlinear effect of connector separation due to bolt preload and axial tension load is described. The automated multilevel substructing capability of COSMIC/NASTRAN was employed at considerable savings in computer run time. Simplified formulas for computer resources, i.e., computer run times for modules SDCOMP, FBS, and MPYAD, as well as disk storage space, are presented. Actual run time data on a VAX-11/780 is compared with the formulas presented.

  18. Pilot Test of Hot Gas Decontamination of Explosives-Contaminated Equipment at Hawthorne Army Ammunition Plant (HWAAP), Hawthorne, Nevada. Appendices. Revision

    DTIC Science & Technology

    1990-06-01

    was used to spike the following items of equipment: 0 powder boxes o steam-heated risers o steam-heated discharge valves o steel pipe o aluminum pipe...expose it to the internal surfaces. For pipe ( aluminum and steel), one end of the pipe section was covered with parafilm wax. Spike solution was added...spike the following items of equipment: "o powder box "o steam-heated riser "o steam-heated discharge valve "O steel pipe "o aluminum pipe Prior to

  19. Modeling of circulating fluised beds for post-combustion carbon capture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, A.; Shadle, L.; Miller, D.

    2011-01-01

    A compartment based model for a circulating fluidized bed reactor has been developed based on experimental observations of riser hydrodynamics. The model uses a cluster based approach to describe the two-phase behavior of circulating fluidized beds. Fundamental mass balance equations have been derived to describe the movement of both gas and solids though the system. Additional work is being performed to develop the correlations required to describe the hydrodynamics of the system. Initial testing of the model with experimental data shows promising results and highlights the importance of including end effects within the model.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fischer, F.J.

    As the petroleum industry has moved into deeper and deeper water for the recovery of oil and gas, weight-sensitive floating platforms have replaced stationary, bottom-founded structures. The cost penalty for weight or vertical tension supported by floaters such as tension leg platforms (TLPs) is in the range of $10--20/kg. Hence, there is considerable incentive to reduce the weight of equipment or structural members on these platforms and downward forces exerted on these platforms by production and export risers, and mooring lines. Thus, there are numerous opportunities for utilizing light-weight, high-strength composites. The offshore petroleum industry has acknowledged the desirable performancemore » characteristics of composites for some time but only recently has there been some optimism that composites could be cost-effective. For most, if not all perceived applications, advanced composites are not considered to be technically enabling for current water depths of interest, i.e., 600--1,200m. However, in a very real sense, they may be economically enabling. In particular, they may allow marginal prospects to be developed or may expedite field development subject to capital constraints. The paper discusses composite production risers, break-even costs and savings, and riser tensioners.« less

  1. IMPACT OF PARTICLE AGGLOMERATION ON ACCUMULATION RATES IN THE GLASS DISCHARGE RISER OF HLW MELTER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matyas, Josef; Jansik, Danielle P.; Owen, Antionette T.

    2013-08-05

    The major factor limiting waste loading in continuous high-level radioactive waste (HLW) melters is an accumulation of particles in the glass discharge riser during a frequent and periodic idling of more than 20 days. An excessive accumulation can produce robust layers a few centimeters thick, which may clog the riser, preventing molten glass from being poured into canisters. Since the accumulation rate is driven by the size of particles we investigated with X-ray microtomography, scanning electron microscopy, and image analysis the impact of spinel forming components, noble metals, and alumina on the size, concentration, and spatial distribution of particles, andmore » on the accumulation rate. Increased concentrations of Fe and Ni in the baseline glass resulted in the formation of large agglomerates that grew over the time to an average size of ~185±155 µm, and produced >3 mm thick layer after 120 h at 850 °C. The noble metals decreased the particle size, and therefore significantly slowed down the accumulation rate. Addition of alumina resulted in the formation of a network of spinel dendrites which prevented accumulation of particles into compact layers.« less

  2. Impact Of Particle Agglomeration On Accumulation Rates In The Glass Discharge Riser Of HLW Melter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruger, A. A.; Rodriguez, C. A.; Matyas, J.

    2012-11-12

    The major factor limiting waste loading in continuous high-level radioactive waste (HLW) melters is an accumulation of particles in the glass discharge riser during a frequent and periodic idling of more than 20 days. An excessive accumulation can produce robust layers a few centimeters thick, which may clog the riser, preventing molten glass from being poured into canisters. Since the accumulation rate is driven by the size of particles we investigated with x-ray microtomography, scanning electron microscopy, and image analysis the impact of spinel forming components, noble metals, and alumina on the size, concentration, and spatial distribution of particles, andmore » on the accumulation rate. Increased concentrations of Fe and Ni in the baseline glass resulted in the formation of large agglomerates that grew over the time to an average size of ~185+-155 {mu}m, and produced >3 mm thick layer after 120 h at 850 deg C. The noble metals decreased the particle size, and therefore significantly slowed down the accumulation rate. Addition of alumina resulted in the formation of a network of spinel dendrites which prevented accumulation of particles into compact layers.« less

  3. Peri-anterior cruciate ligament reconstruction femur fracture: a biomechanical analysis of the femoral tunnel as a stress riser.

    PubMed

    Han, Yung; Sardar, Zeeshan; McGrail, Scott; Steffen, Thomas; Martineau, Paul A

    2011-12-01

    Sixteen case reports of distal femur fractures as post-operative complications after anterior cruciate ligament (ACL) reconstruction have been described in the literature. The femoral tunnel has been suggested as a potential stress riser for fracture formation. Additionally, double bundle ACL reconstructions may compound this risk. This is the first biomechanical study to examine the significance of a stress riser effect of the femoral tunnel(s) after ACL reconstruction. The hypotheses tested in this study are that the femoral tunnel acts as a stress riser for fracture and that this effect increases with the size of the tunnel (8 mm vs. 10 mm) and with the number of tunnels (1 vs. 2). Femoral tunnels simulating single bundle (SB) hamstring graft (8 mm), bone-patellar tendon-bone graft (10 mm), and double bundle (DB) ACL reconstruction (7, 6 mm) were drilled in fourth-generation saw bones. These three experimental groups and a control group consisting of native saw bones without tunnels were loaded to failure. All fractures occurred through the tunnels in the DB group, whereas fractures did not consistently occur through the tunnels in the SB groups. The mean fracture load was 6,145N ± 471N in the native group, 5,691N ± 198N in the 8 mm SB group, 5,702N ± 282N in the 10 mm SB group, and 4,744N ± 418N in the DB group. The mean fracture load for the DB group was significantly lower when compared to the native, 8 mm SB, and 10 mm SB groups independently (P value = 0.0016, 0.0060, and 0.0038, respectively). The mean fracture loads for neither SB groups were not significantly different from the native group. An anatomically placed femoral tunnel in single bundle ACL reconstruction in our experimental model was not a significant stress riser to fracture, whereas the two femoral tunnels in double bundle ACL reconstruction significantly decreased load to failure. The results support the sparsity of reported peri-ACL reconstruction femur fractures in single femoral tunnel techniques. However, the increased fracture risk in double bundle ACL reconstruction may be a cause for concern and impact patient selection.

  4. Divers muscle Fitzpatrick`s mussels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hobbs, B.; Kahabka, J.

    1996-01-01

    This article describes how an effective manual cleaning technique has helped rid submerged intake structures of this passive-aggressive pest. The New York Power Authority`s (NYPA) James A. Fitzpatrick (JAF) Nuclear Power Plant is located in Lycoming, NY, on the southeast shore of Lake Ontario. An 850-MWe, GE-design boiling water reactor (BWR), the unit has been in service since 1975. Water drawn from the Lake supplies cooling to plant loads via the circulating water system and three service water systems. These share a common intake system consisting of an offshore cap (crib), horizontal intake tunnel, two vertical risers and forebay/screenwell area.

  5. Using Microporous Polytetrafluoroethylene Thin Sheets as a Flexible Solar Diffuser to Minimize Sunlight Glint to Cameras in Space

    NASA Technical Reports Server (NTRS)

    Choi, Michael K.

    2016-01-01

    An innovative design of using microporous PTFE thin sheets as a solar diffuser for MLI blankets or mechanical structure has been developed. It minimizes sunlight or stray-light glint to cameras when it is incident on these components in space. A microporous black PTFE thin sheet solar diffuser has been qualified for flight at NASA GSFC and installed to the TAGSAM arm MLI, OCAMS PolyCam sunshade MLI and SamCam motor riser MLI in the NASA OSIRIS-REx mission to meet the SamCam camera BRDF requirement.

  6. Using microporous polytetrafluoroethylene thin sheets as a flexible solar diffuser to minimize sunlight glint to cameras in space

    NASA Astrophysics Data System (ADS)

    Choi, Michael K.

    2016-09-01

    An innovative design of using microporous PTFE thin sheets as a solar diffuser for MLI blankets or mechanical structure has been developed. It minimizes sunlight or stray-light glint to cameras when it is incident on these components in space. A microporous black PTFE thin sheet solar diffuser has been qualified for flight at NASA GSFC and installed to the TAGSAM arm MLI, OCAMS PolyCam sunshade MLI and SamCam motor riser MLI in the NASA OSIRIS-REx mission to meet the SamCam camera BRDF requirement.

  7. Innovative concepts for marginal fields (advanced monotower developments)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, M.T.; Marks, V.E.

    1995-12-01

    The braced monotower provides a safe, functional and cost effective solution for topsides up to 500 tonnes, with up to 8 wells and standing in water depths of up to 70 meters. It is both simple in concept and structurally efficient. The superstructure is supported by a single column which is stayed by three symmetrically orientated legs. A broad mudline base is also provided to limit pile loads. The final concept offers complete protection to the risers and conductors from ship impact, as all appurtenances are housed within the central column. The basic design philosophy of the low intervention platformmore » is to minimize the onboard equipment to that vitally needed to produce hydrocarbon. The concept eliminates the life support functions that on a normal North Sea platform can contribute up to 50% of the topside dry weight. A system of Zero Based Engineering is used that ensures each item of equipment contributes more to the NPV of the platform than the fully built-up through life cost. This effectively eliminates the operator preference factor and the ``culture`` cost.« less

  8. Discovery of the First Leaking Double-Shell Tank - Hanford Tank 241-AY-102

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harrington, Stephanie J.; Sams, Terry L.

    Full text - Long Abstract. A routine video inspection of the annulus region of double-shell tank 241-A Y-102 in August of 2012 indicated the presence material in the annulus space between the primary and secondary liners. A comparison was made to previous inspections performed in 2006 and 2007. which indicated that a change had occurred. The material was observed at two locations on the floor of the annulus and one location at the top of the annulus region where the primary and secondary top knuckles meet (RPP-ASMT-53793). Subsequent inspections were performed. leading to additional material observed on the floor ofmore » the annulus space in a region that had not previously been inspected (WRPS-PER-2012-1363). The annulus Continuous Air Monitor (CAM) was still operational and was not indicating elevated radiation levels in the annulus region. When the camera from the inspections was recovered. it also did not indicate increased radiation above minimum contamination levels (WRPS-PER-2012-1363). A formal leak assessment team was established August 10, 2012 to review tank 241-AY-102 construction and operating histories and to determine whether the material observed in the annulus had resulted from a leak in the primary tank. The team consisted of individuals from Engineering. Base Operations and Environmental Protection. As this was a first-of-its-kind task. a method for obtaining a sample of the material in the annulus was needed. The consistency of the material was unknown.and the location of a majority of the material was not conducive to using the sampling devices that were currently available at Hanford. A subcontractor was tasked with the development fabrication.and testing of a sampling device that would be able to obtain multiple samples from the material on the annulus floor. as well as the material originating from a refractory air-slot near the floor of the annulus space. This sampler would need to be able to collect and dispense the material it collected into a sample jar retrieval device for transportation of the material to the 222-S laboratory on the Hanford site for analysis. The subcontractor agency fabricated a remote underground sampler by modifying off-the-shelf robotics and parts. Limited testing of the sampler was conducted using a mock-up of the tank annulus and one simulated material type -a salt block. The mock-up testing indicated that the sampler would be able to maneuver within the confined space and that the device worked with full functionality. A total of six weeks had passed from initiation to implementation of the new sampler in the 241-AY-102 tank annulus. Initial sample material was obtained from the annulus floor using the Off-Riser Sampler System that has been used at Hanford tor years to obtain material from the primary tanks. This could be used at the location near Riser 83 since the material was collected directly from the annulus floor and not from a location on the wall or behind a pipe, as was needed from the two locations near Riser 90. After obtaining a small sample of the material on the annulus floor.this sampler sustained terminal damage due to conduit pipes it had to transverse in order to collect and recover material from this location. Several issues were also encountered during deployment of the new sampler into the annulus near Riser 90. These included: Difficulty fitting the sampler down the 12-inch riser into the annulus due to a small tolerance in the size of the sampler; Failure of sampler components and functions during deployment including the camera. pneumatics.and bearing seals; Delays in the field due to supporting equipment issues including cables. cameras. and scaffolding; and, Low recovery of sample material obtained for analysis. The complications that occurred during deployment and use of the new sampler during the sampling event ultimately resulted in lower recovery of material from these locations in the annulus than was obtained using the Off-Riser Sampler System and limited the analyses that could be performed for determining the origin of the material. Following completion of the sample analyses and the assessment of its construction history and use. there was a consensus among the leak assessment team members that two of the three materials sampled from the annulus floor region were the result of waste leaking from a breach in the primary tank. The probable leak cause was identified as corrosion at high temperatures in a tank whose containment margins had been reduced due to construction difficulties (RPP-ASMT-53793). A formal Lessons Learned was created concerning designing equipment tor unique purposes under time constraints. This document was published in OPEXShare on May 20. 2013. It highlighted some of the issues that arose with the subcontractor sampler development and provided recommendations to prevent a recurrence should this task need to be performed again in the future. The document can be found at http://msa.hanford.gov/opex/lesson.cfm/2013/5/20/3481/AY-102-Annulus-Sampler-Designing-Equipment-for-Unique-Purposes-under-Time-Constraints/.« less

  9. Gray Infrastructure Tool | EPA Center for Exposure ...

    EPA Pesticide Factsheets

    2016-03-07

    Natural channel with flood plain panel added Default depth increment of 0.5 is used for Natural Channel with FP Units option added – SI or US units. Default option is US units Conversion options added wherever necessary Additional options added to FTABLE such as clear FTABLE Significant digits for FTABLE calculations is changed to 4 Previously a default Cd value is used for calculations (under-drain and riser) but now a user defined value is used Default values of Cd for riser orifice and under-drain textboxes is changed to 0.6 Previously a default increment value of 0.1 is used for all the channel panels but now user can specify the increment

  10. Tibial plateau fracture after anterior cruciate ligament reconstruction: Role of the interference screw resorption in the stress riser effect.

    PubMed

    Thaunat, Mathieu; Nourissat, Geoffroy; Gaudin, Pascal; Beaufils, Philippe

    2006-06-01

    We report a case of tibial plateau fracture after previous anterior cruciate ligament (ACL) reconstruction using patellar tendon autograft and bioabsorbable screws 4 years previously. The fracture occurred through the tibial tunnel. The interference screw had undergone complete resorption and the tunnel widening had increased. The resorption of the interference screw did not simultaneously promote and foster the growth of surrounding bone tissue. Therefore, the area of reactive tissue left by the screw resorption in an enlarged bone tunnel may lead to vulnerability of the tibial plateau. Stress risers would occur following ACL reconstruction if either resorption is not complete or bony integration is not complete.

  11. Parachute dynamics and stability analysis. [using nonlinear differential equations of motion

    NASA Technical Reports Server (NTRS)

    Ibrahim, S. K.; Engdahl, R. A.

    1974-01-01

    The nonlinear differential equations of motion for a general parachute-riser-payload system are developed. The resulting math model is then applied for analyzing the descent dynamics and stability characteristics of both the drogue stabilization phase and the main descent phase of the space shuttle solid rocket booster (SRB) recovery system. The formulation of the problem is characterized by a minimum number of simplifying assumptions and full application of state-of-the-art parachute technology. The parachute suspension lines and the parachute risers can be modeled as elastic elements, and the whole system may be subjected to specified wind and gust profiles in order to assess their effects on the stability of the recovery system.

  12. Mechanical fatigue resistance of an implantable branched lead system for a distributed set of longitudinal intrafascicular electrodes

    NASA Astrophysics Data System (ADS)

    Pena, A. E.; Kuntaegowdanahalli, S. S.; Abbas, J. J.; Patrick, J.; Horch, K. W.; Jung, R.

    2017-12-01

    Objective. A neural interface system has been developed that consists of an implantable stimulator/recorder can with a 15-electrode lead that trifurcates into three bundles of five individual wire longitudinal intrafascicular electrodes. This work evaluated the mechanical fatigue resistance of the branched lead and distributed electrode system under conditions designed to mimic anticipated strain profiles that would be observed after implantation in the human upper arm. Approach. Custom test setups and procedures were developed to apply linear or angular strain at four critical stress riser points on the lead and electrode system. Each test was performed to evaluate fatigue under a high repetition/low amplitude paradigm designed to test the effects of arm movement on the leads during activities such as walking, or under a low repetition/high amplitude paradigm designed to test the effects of more strenuous upper arm activities. The tests were performed on representative samples of the implantable lead system for human use. The specimens were fabricated using procedures equivalent to those that will be used during production of human-use implants. Electrical and visual inspections of all test specimens were performed before and after the testing procedures to assess lead integrity. Main results. Measurements obtained before and after applying repetitive strain indicated that all test specimens retained electrical continuity and that electrical impedance remained well below pre-specified thresholds for detection of breakage. Visual inspection under a microscope at 10×  magnification did not reveal any signs of damage to the wires or silicone sheathing at the stress riser points. Significance. These results demonstrate that the branched lead of this implantable neural interface system has sufficient mechanical fatigue resistance to withstand strain profiles anticipated when the system is implanted in an arm. The novel test setups and paradigms may be useful in testing other lead systems.

  13. Fracture during intravenous bisphosphonate treatment in a child with osteogenesis imperfecta: an argument for a more frequent, low-dose treatment regimen.

    PubMed

    Biggin, Andrew; Briody, Julie N; Ormshaw, Elizabeth; Wong, Karen K Y; Bennetts, Bruce H; Munns, Craig F

    2014-01-01

    Intravenous bisphosphonate therapy is the mainstay of medical treatment in osteogenesis imperfecta (OI) and has been shown to increase bone mass, decrease bone pain, improve mobility, and reduce the incidence of fractures. Sclerotic metaphyseal lines parallel to the growth plate are seen on long bone radiographs following cyclical intravenous therapy. These areas create stress risers within the bone that may act as foci for subsequent fractures as exemplified in this clinical case. An 8-year-old girl with OI sustained a distal radial fracture following 3 years of treatment with 6-monthly intravenous zoledronate. Her diagnosis, response to treatment, and subsequent fracture at a sclerotic metaphyseal line is described. Peripheral quantitative computer tomography was used to characterise the presence of multiple stress risers at the distal forearm. Trabecular bone mineral density fluctuated from 34 to 126% compared to neighbouring 2-mm regions. There remain many unanswered questions about optimal bisphosphonate treatment regimens in children with OI. The formation of stress risers following intravenous bisphosphonate treatment raises the hypothesis that a more frequent and low-dose bisphosphonate regimen would provide more uniform dosing of bone in the growing child and reduce the likelihood of fractures compared to current treatment practices.

  14. B-type natriuretic peptide is a determinant of the nocturnal increase in blood pressure independently of arterial hypertrophy and hypoxia.

    PubMed

    Tabara, Yasuharu; Igase, Michiya; Miki, Tetsuro; Ohyagi, Yasumasa; Matsuda, Fumihiko; Kohara, Katsuhiko

    2016-12-01

    Loss of the nocturnal blood pressure (BP) drop is a risk factor for cardiovascular outcomes. However, clinical parameters that predispose to changes in nocturnal BP are currently uncertain. Given the possible involvement of salt sensitivity in nocturnal BP levels, we investigated a hypothesized association between plasma B-type natriuretic peptide (BNP) levels - a marker of body fluid retention - and nocturnal BP in a general population. Study participants were 1020 general individuals. Participants were divided into four groups (riser, nondipper, dipper, and extreme dipper) by their percentage changes in nocturnal SBP measured using an ambulatory BP monitor. Plasma BNP levels were positively associated with circadian BP change (β = 0.162, P < 0.001) independently of carotid hypertrophy (β = 0.133, P < 0.001), and awake heart rate (β = -0.102, P = 0.001) and SBP (β = -0.246, P < 0.001). Risers showed 1.6 times higher BNP levels than dippers, whereas oxygen desaturation during sleep was frequently observed in nondippers. Results of multinomial logistic regression analysis indicated that BNP level was a significant determinant for the riser pattern [odds ratio (OR) 1.27 (BNP 10 pg/ml), P < 0.001], whereas oxygen desaturation was specifically associated with the nondipping pattern (OR 1.04, P = 0.001). When participants were subdivided by BNP level, risers were more frequent in the high BNP subgroup (19.5%) than in the low BNP subgroup (6.7%) (OR 3.39, P < 0.001). A slight increase in plasma BNP level was independently associated with rising nocturnal BP. Our results may help to understand the pathophysiology of circadian BP variation, and be a clue to identify individuals who require careful BP monitoring.

  15. Recent scientific and operational achievements of D/V Chikyu

    NASA Astrophysics Data System (ADS)

    Taira, Asahiko; Toczko, Sean; Eguchi, Nobu; Kuramoto, Shin'ichi; Kubo, Yusuke; Azuma, Wataru

    2014-12-01

    The D/V Chikyu, a scientific drilling vessel, is equipped with industry-standard riser capabilities. Riser drilling technology enables remarkable drilling and downhole logging capabilities and provides unprecedented hole-stability, enabling the shipboard team to retrieve high-quality wire-line logging data as well as well-preserved core samples. The 11 March 2011 Tohoku Oki mega-earthquake and tsunami cost over 18,000 casualties in NE Japan. Chikyu, docked in the Port of Hachinohe, was damaged by the tsunami. By April 2012, the ship was back in operation; drilling the toe of the Japan Trench fault zone where topographic surveys suggested there was up to 50 m eastward motion, the largest earthquake rupture ever recorded. During Integrated Ocean Drilling Program (IODP) Expeditions 343 and 343 T, Chikyu drilled 850 m below sea floor (mbsf) in 6,900+ m water depth and recovered core samples of a highly brecciated shear zone composed of pelagic claystone. A subseafloor observatory looking for temperature signatures caused by the fault friction during the earthquake, was installed and later successfully recovered. The recovered temperature loggers recorded data from which the level of friction during the mega-earthquake slip could be determined. Following Exp. 343, Chikyu began IODP Exp. 337, a riser drilling expedition into the Shimokita coal beds off Hachinohe, to study the deep subsurface biosphere in sedimentary units including Paleogene-Neogene coal beds. New records in scientific ocean drilling were achieved in deepest penetration (drilling reached 2,466 mbsf) and sample recovery. Currently Chikyu is conducting deep riser drilling at the Nankai Trough in the final stage of the NanTroSEIZE campaign. During the years 2011 to 2013, including drilling in the Okinawa Hydrothermal System, Chikyu's operational and scientific achievements have demonstrated that the ship's capabilities are vital for opening new frontiers in earth and biological sciences.

  16. Design, fabrication, and integration testing of the Garden Banks 388 subsea production template

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ledbetter, W.R.; Smith, D.W.; Pierce, D.M.

    1995-12-31

    Enserch Exploration`s Garden Banks 388 development has a production scheme based around a floating drilling and production facility and subsea drilling/production template. The Floating Production Facility (FPF) is a converted semisubmersible drilling rig that will drill and produce through a 24-well slot subsea template. This development is located in Block 388 of the Garden Banks area in the Gulf of Mexico approximately 200 miles southwest of New Orleans, Louisiana. The production system is being installed in an area of known oil and gas reserves and will produce to a shallow water platform 54 miles away at Eugene Island 315. Themore » FPF will be permanently moored above the template. The subsea template has been installed in 2190 feet of water and will produce through a 2,000 foot free-standing production riser system to the FPF. The produced fluids are partially separated on the FPF before oil and gas are pumped through the template to export gathering lines that are connected to the shallow water facility. The system designed through-put is 40,000 BOPD of oil and 120 MMSCFD of gas.« less

  17. Workshop on Condition Based Maintenance Held in Atlantic Beach, North Carolina on November 15 - 17, 1993

    DTIC Science & Technology

    1993-11-17

    pounds of Torque Over Three Minutes Continuous Operation IYMCO1A 14 DMAE Corporation C-130 Engine Gearbox January 19925 Stress Wave Analysis - I in’. I...FaUi.O The CBM needs associated with surface initiated failure mechanisms can be divided into I singular defects and low (h/a) operation. Singular defec-t...These include nicks, scratches, corrosion pits and dents caused by third’ body particles (hard or soft). These defects cause local stress risers

  18. Controlling factors of turf-banked solifluction lobe evolution in the Turtmann glacier forefield (Switzerland)

    NASA Astrophysics Data System (ADS)

    Draebing, Daniel; Eichel, Jana

    2016-04-01

    Soil structure and moisture, thermal conditions and vegetation control solifluction movement, however, the spatial distribution of controlling factors and resultant spatial variability of movement are poorly understood. We use a (1) geomorphological and vegetation mapping of solifluction lobe properties, (2) temperature loggers to quantify thermal conditions, (3) 2D Electrical Resistivity Tomography (ERT), Puerkhauer drilling and TDR measurements to evaluate material properties as well as (4) 3D Time-Lapse ERT to quantify spatial variability of material properties. Our results are used to (5) evaluate the influence of potential controlling factors on solifluction movement. Investigations took place on three turf-banked lobes (TBL) located at proximal and distal slopes of Little Ice Age and 1920s lateral moraines in the Turtmann glacier forefield, Swiss Alps. (1) Vegetation is spatially differentiated at TBLs. The treads are mostly covered by the ecosystem engineer Dryas octopetala, while other dwarf shrubs, shrubs and pioneer species were found at the high lobe risers (0.8-1.8 m). In contrast, less vegetated ridge-like features at the upper part of the treads are colonized by frost-tolerant species. Large blocks are located at the lobe fronts, probably impeding the lobe movement. (2) Temperature loggers show a lack of ground cooling due to snow isolation at the vegetated lower tread between 2014 and 2015. Thus, significant ground cooling in winter is reduced to the wind-exposed upper parts (ridges). (3) TBL material consists of sandy silt, thus, lobe material is much finer than subjacent moraine till and indicates former colluviation. As a consequence, 2D ERT demonstrates low-resistant areas until depths equal to riser height, thus, the finer TBL body is higher saturated than the coarser surrounding parent slope and more susceptible to gelifluction. On the contrary, risers show high resistivities indicating dry conditions which are supported by TDR results. Furthermore, ERT demonstrates the absence of permafrost in all measured TBLs. (4) Time-Lapse 3D ERT shows low-resistant areas at the rim of lobes in contrast to the high-resistant treads. In addition, resistivity increases with TBL depth. Thus, resistivity values indicate higher saturated conditions along the lobe axis with decreasing saturated conditions at the rim. (5) High-saturated conditions favour gelifluction movement while low-freezing activity and dense vegetation cover result in a lack of ice lenses and absence of permafrost and, thus, impermeable layers. Therefore, the highly permeable material favours drainage and seepage without development of critical pore water pressures. The D. octopetala mat on the tread increases near-surface shear strength, which decreases near-surface movement. In addition, later successional shrubs species colonizing the risers indicate limited frontal movement. As a consequence, our results suggest that solifluction movement is limited to the low- vegetation cover, highly saturated parts of the lobe affected by winter ground cooling. However, the large riser height reflects high past solifluction activity. Location of the lobes at the foot of slopes and large riser height indicate that TBLs are close to their final cycle of development. Due to the moraine age, the length of the cycle can be assumed to be maximum 100 years.

  19. Baseline Design Compliance Matrix for the Rotary Mode Core Sampling System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LECHELT, J.A.

    2000-10-17

    The purpose of the design compliance matrix (DCM) is to provide a single-source document of all design requirements associated with the fifteen subsystems that make up the rotary mode core sampling (RMCS) system. It is intended to be the baseline requirement document for the RMCS system and to be used in governing all future design and design verification activities associated with it. This document is the DCM for the RMCS system used on Hanford single-shell radioactive waste storage tanks. This includes the Exhauster System, Rotary Mode Core Sample Trucks, Universal Sampling System, Diesel Generator System, Distribution Trailer, X-Ray Cart System,more » Breathing Air Compressor, Nitrogen Supply Trailer, Casks and Cask Truck, Service Trailer, Core Sampling Riser Equipment, Core Sampling Support Trucks, Foot Clamp, Ramps and Platforms and Purged Camera System. Excluded items are tools such as light plants and light stands. Other items such as the breather inlet filter are covered by a different design baseline. In this case, the inlet breather filter is covered by the Tank Farms Design Compliance Matrix.« less

  20. Corrosion of stainless steels in the riser during co-processing of bio-oils in a fluid catalytic cracking pilot plant

    DOE PAGES

    Brady, M. P.; Keiser, J. R.; Leonard, D. N.; ...

    2017-01-31

    Co-processing of bio-oils with conventional petroleum-based feedstocks is an attractive initial option to make use of renewable biomass as a fuel source while leveraging existing refinery infrastructures. But, bio-oils and their processing intermediates have high concentrations of organic oxygenates, which, among their other negative qualities, can result in increased corrosion issues. A range of stainless steel alloys (409, 410, 304L, 316L, 317L, and 201) was exposed at the base of the riser in a fluid catalytic cracking pilot plant while co-processing vacuum gas oil with pine-derived pyrolysis bio-oils that had been catalytically hydrodeoxygenated to ~ 2 to 28% oxygen. Wemore » studied the processing using a catalyst temperature of 704 °C, a reaction exit temperature of 520 °C, and total co-processing run times of 57–75 h. External oxide scaling 5–30 μm thick and internal attack 1–5 μm deep were observed in these short-duration exposures. The greatest extent of internal attack was observed for co-processing with the least stabilized bio-oil, and more so for types 409, 410, 304L, 316L, 317L stainless steel than for type 201. Finally, the internal attack involved porous Cr-rich oxide formation, associated with local Ni-metal enrichment and S-rich nanoparticles, primarily containing Cr or Mn. Implications for alloy selection and corrosion are discussed.« less

  1. Corrosion of stainless steels in the riser during co-processing of bio-oils in a fluid catalytic cracking pilot plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brady, M. P.; Keiser, J. R.; Leonard, D. N.

    Co-processing of bio-oils with conventional petroleum-based feedstocks is an attractive initial option to make use of renewable biomass as a fuel source while leveraging existing refinery infrastructures. But, bio-oils and their processing intermediates have high concentrations of organic oxygenates, which, among their other negative qualities, can result in increased corrosion issues. A range of stainless steel alloys (409, 410, 304L, 316L, 317L, and 201) was exposed at the base of the riser in a fluid catalytic cracking pilot plant while co-processing vacuum gas oil with pine-derived pyrolysis bio-oils that had been catalytically hydrodeoxygenated to ~ 2 to 28% oxygen. Wemore » studied the processing using a catalyst temperature of 704 °C, a reaction exit temperature of 520 °C, and total co-processing run times of 57–75 h. External oxide scaling 5–30 μm thick and internal attack 1–5 μm deep were observed in these short-duration exposures. The greatest extent of internal attack was observed for co-processing with the least stabilized bio-oil, and more so for types 409, 410, 304L, 316L, 317L stainless steel than for type 201. Finally, the internal attack involved porous Cr-rich oxide formation, associated with local Ni-metal enrichment and S-rich nanoparticles, primarily containing Cr or Mn. Implications for alloy selection and corrosion are discussed.« less

  2. Performance and stability analysis of gas-injection enhanced natural circulation in heavy-liquid-metal-cooled systems

    NASA Astrophysics Data System (ADS)

    Yoo, Yeon-Jong

    The purpose of this study is to investigate the performance and stability of the gas-injection enhanced natural circulation in heavy-liquid-metal-cooled systems. The target system is STAR-LM, which is a 400-MWt-class advanced lead-cooled fast reactor under development by Argonne National Laboratory and Oregon State University. The primary loop of STAR-LM relies on natural circulation to eliminate main circulation pumps for enhancement of passive safety. To significantly increase the natural circulation flow rate for the incorporation of potential future power uprates, the injection of noncondensable gas into the coolant above the core is envisioned ("gas lift pump"). Reliance upon gas-injection enhanced natural circulation raises the concern of flow instability due to the relatively high temperature change in the reactor core and the two-phase flow condition in the riser. For this study, the one-dimensional flow field equations were applied to each flow section and the mixture models of two-phase flow, i.e., both the homogeneous and drift-flux equilibrium models were used in the two-phase region of the riser. For the stability analysis, the linear perturbation technique based on the frequency-domain approach was used by employing the Nyquist stability criterion and a numerical root search method. It has been shown that the thermal power of the STAR-LM natural circulation system could be increased from 400 up to 1152 MW with gas injection under the limiting void fraction of 0.30 and limiting coolant velocity of 2.0 m/s from the steady-state performance analysis. As the result of the linear stability analysis, it has turned out that the STAR-LM natural circulation system would be stable even with gas injection. In addition, through the parametric study, it has been found that the thermal inertia effects of solid structures such as fuel rod and heat exchanger tube should be considered in the stability analysis model. The results of this study will be a part of the optimized stable design of the gas-injection enhanced natural circulation of STAR-LM with substantially improved power level and economical competitiveness. Furthermore, combined with the parametric study, this research could contribute a guideline for the design of other similar heavy-liquid-metal-cooled natural circulation systems with gas injection.

  3. Katie Gaston | NREL

    Science.gov Websites

    gasification. The new catalytic riser reactor system can be used for ex situ vapor-phase upgrading or steam , and Wood: 1. Parametric Study and Comparison with Literature," Industrial & Engineering

  4. 242-16H 2H EVAPORATOR POT SAMPLING FINAL REPORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krementz, D; William Cheng, W

    2008-06-11

    Due to the materials that are processed through 2H Evaporator, scale is constantly being deposited on the surfaces of the evaporator pot. In order to meet the requirements of the Nuclear Criticality Safety Analysis/Evaluation (NCSA/NCSE) for 2H Evaporator, inspections of the pot are performed to determine the extent of scaling. Once the volume of scale reaches a certain threshold, the pot must be chemically cleaned to remove the scale. Prior to cleaning the pot, samples of the scale are obtained to determine the concentration of uranium and plutonium and also to provide information to assist with pot cleaning. Savannah Rivermore » National Laboratory (SRNL) was requested by Liquid Waste Organization (LWO) Engineering to obtain these samples from two locations within the evaporator. Past experience has proven the difficulty of successfully obtaining solids samples from the 2H Evaporator pot. To mitigate this risk, a total of four samplers were designed and fabricated to ensure that two samples could be obtained. Samples had previously been obtained from the cone surface directly below the vertical access riser using a custom scraping tool. This tool was fabricated and deployed successfully. A second scraper was designed to obtain sample from the nearby vertical thermowell and a third scraper was designed to obtain sample from the vertical pot wall. The newly developed scrapers both employed a pneumatically actuated elbow. The scrapers were designed to be easily attached/removed from the elbow assembly. These tools were fabricated and deployed successfully. A fourth tool was designed to obtain sample from the opposite side of the pot under the tube bundle. This tool was fabricated and tested, but the additional modifications required to make the tool field-ready could not be complete in time to meet the aggressive deployment schedule. Two samples were obtained near the pot entry location, one from the pot wall and the other from the evaporator feed pipe. Since a third sampler was available and all of the radiological controls were in place, the decision was made to obtain a third sample. The third sampler dropped directly below the riser to obtain a scrape sample from the evaporator cone. Samples were obtained from all of these locations in sufficient quantities to perform the required analysis.« less

  5. Multi-fluid CFD analysis in Process Engineering

    NASA Astrophysics Data System (ADS)

    Hjertager, B. H.

    2017-12-01

    An overview of modelling and simulation of flow processes in gas/particle and gas/liquid systems are presented. Particular emphasis is given to computational fluid dynamics (CFD) models that use the multi-dimensional multi-fluid techniques. Turbulence modelling strategies for gas/particle flows based on the kinetic theory for granular flows are given. Sub models for the interfacial transfer processes and chemical kinetics modelling are presented. Examples are shown for some gas/particle systems including flow and chemical reaction in risers as well as gas/liquid systems including bubble columns and stirred tanks.

  6. C6 GPMG and 40 mm AGL Weapon Integrated on RWS Mounted on TAPV Platform: Probability of Hit Methodology

    DTIC Science & Technology

    2010-09-01

    nationale, 2010 DRDC Valcartier CR 2010-237 i Abstract …….. A probability of hit ( PHit ) methodology has been developed to characterize the...CFB (Canadian Forces Base). Résumé …..... Une méthodologie de probabilité d’impact ( PHit ) a été développée pour caractériser la performance globale...the crew commander and gunner from their respective crew stations inside the vehicle. A probability of hit ( PHit ) methodology has been developed to

  7. 77 FR 57534 - Airworthiness Directives; Piper Aircraft, Inc. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-18

    ... turbocharger (uncoupled) for cracks, distortion, and evidence indicative of improper surface mating. (3) Inspect the three exhaust system slip joints between each turbocharger and its closest riser for seizure...

  8. New Era of Scientific Ocean Drilling

    NASA Astrophysics Data System (ADS)

    Eguchi, N.; Toczko, S.; Sanada, Y.; Igarashi, C.; Kubo, Y.; Maeda, L.; Sawada, I.; Takase, K.; Kyo, N.

    2014-12-01

    The D/V Chikyu, committed to scientific ocean drilling since 2007, has completed thirteen IODP expeditions, and Chikyu's enhanced drilling technology gives us the means to reach deep targets, enhanced well logging, deep water riserless drilling, and state of the art laboratory. Chikyu recovered core samples from 2466 meters below sea floor (mbsf) in IODP Exp. 337, and drilled to 3058.5 mbsf in IODP Exp. 348, but these are still not the limit of Chikyu's capability. As deep as these depths are, they are just halfway to the 5200 mbsf plate boundary target for the NanTroSEIZE deep riser borehole. There are several active IODP proposals in the pipeline. Each has scientific targets requiring several thousand meters of penetration below the sea floor. Riser technology is the only way to collect samples and data from that depth. Well logging has been enhanced with the adoption of riser drilling, especially for logging-while-drilling (LWD). LWD has several advantages over wireline logging, and provides more opportunities for continuous measurements even in unstable boreholes. Because of the larger diameter of riser pipes and enhanced borehole stability, Chikyu can use several state-of-the-art downhole tools, e.g. fracture tester, fluid sampling tool, wider borehole imaging, and the latest sonic tools. These new technologies and tools can potentially expand the envelope of scientific ocean drilling. Chikyu gives us access to ultra-deep water riserless drilling. IODP Exp. 343/343T investigating the March 2011 Tohoku Oki Earthquake, explored the toe of the landward slope of the Japan Trench. This expedition reached the plate boundary fault target at more than 800 mbsf in water depths over 6900 m for logging-while-drilling, coring, and observatory installation. This deep-water drilling capability also expands the scientific ocean drilling envelope and provides access to previously unreachable targets. On top of these operational capabilities, Chikyu's onboard laboratory is equipped with state-of-the-art instruments to analyze all science samples. X-ray CT creates non-destructive 3D images of core samples providing high resolution structural detail. The microbiology laboratory offers clean and contamination-free work environments required for microbiological samples.

  9. Large Scale Geomorphic Mapping of Cryoplanation Terraces in Central and Eastern Alaska

    NASA Astrophysics Data System (ADS)

    Queen, C.; Nyland, K. E.; Nelson, F. E.

    2017-12-01

    Cryoplanation terraces (CTs) are large periglacial landforms characterized by alternating treads and risers, giving the appearance of giant staircases ascending ridgecrests and hillsides. The risers (scarps) are typically covered with coarse clastic material, while the surfaces of the nearly planar treads are a mosaic of vegetation, rock debris, and surficial periglacial landforms. CTs are best developed in areas of moderate relief across Beringia, the largely unglaciated region between the Lena and Mackenzie rivers, including Bering Sea islands that were formerly highlands on the Bering Land Bridge. CTs are generally thought to develop through locally intensified weathering at the base of scarps by processes associated with late lying bodies of snow. This hypothesis has been the subject of much speculative literature, but until recently there have been few process-oriented field studies performed on them. The work reported here builds on foundational work by R. D. Reger, who inventoried and investigated a large number of CTs in central and western Alaska. The resultant large-scale (1:2000) maps of cryoplanation terraces at Eagle Summit and Mount Fairplay in east-central Alaska were created using traditional and GPS-based mapping methodologies. Pits were excavated at representative locations across treads to obtain information about subsurface characteristics. The resulting maps show the location and morphology of surficial geomorphic features on CT scarps, treads, and sideslopes, superimposed on high-resolution topographic maps and perspective diagrams. GIS-based analysis of the assembled map layers promotes three-dimensional understanding of the spatial relationships between CT morphology, material properties, and erosional processes, and provides key insights into intra- and inter- terrace relationships. In concert with relative and absolute dating of material on the landforms, this research is generally supportive of the "nivation hypothesis of CT development."

  10. 30 CFR 291.101 - What definitions apply to this part?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... equipment, device, apparatus, or other object attached to a horizontal component or riser. Examples include...), pipeline end terminals (PLETs), anode sleds, other sleds, and jumpers (other than jumpers connecting subsea...

  11. 11. Historic American Buildings Survey E. W. Russell, Photographer, June ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. Historic American Buildings Survey E. W. Russell, Photographer, June 17, 1937 FIREPLACE, NORTH WALL OF NORTH SIDE FRONT ROOM OF MAIN HOUSE. - Wewoka, Riser Mill Road, Sylacauga, Talladega County, AL

  12. 46. Historic American Buildings Survey, Donald W. Dickensheets, Photographer. March ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. Historic American Buildings Survey, Donald W. Dickensheets, Photographer. March 28, 1940. RISERS, STAIRWAY TO WEST TOWER. (EAST ELEVATION) - San Xavier del Bac Mission, Mission Road, Tucson, Pima County, AZ

  13. 31. Stair Plans / First Floor, Second Floor, Section Stair ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. Stair Plans / First Floor, Second Floor, Section Stair Bulkhead, F.S. Tread & Riser (drawing 8) - Whittier State School, Hospital & Receiving Building, 11850 East Whittier Boulevard, Whittier, Los Angeles County, CA

  14. 14. Historic American Buildings Survey E. W. Russell, Photographer, June ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Historic American Buildings Survey E. W. Russell, Photographer, June 17, 1937 OLD WATER POWER GRIST MILL, NORTHEAST OF MAIN HOUSE, LOOKING EAST. - Wewoka, Riser Mill Road, Sylacauga, Talladega County, AL

  15. 10. Historic American Buildings Survey E. W. Russell, Photographer, June ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Historic American Buildings Survey E. W. Russell, Photographer, June 17, 1937 FIREPLACE AND MANTEL. SOUTH WALL OF SOUTH FRONT ROOM, FIRST STORY. - Wewoka, Riser Mill Road, Sylacauga, Talladega County, AL

  16. 12. Historic American Buildings Survey E. W. Russell, Photographer, June ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    12. Historic American Buildings Survey E. W. Russell, Photographer, June 17, 1937 FIREPLACE AND MANTEL, SOUTH WALL OF SOUTH SIDE ROOM, SECOND STORY. - Wewoka, Riser Mill Road, Sylacauga, Talladega County, AL

  17. 40 CFR 745.82 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., such as the individual stair treads and risers of a single staircase, the renovator is required to test... occur in the owner's residence, no child under age 6 resides there, no pregnant woman resides there, the...

  18. Spinoff For Deepsea Drillships

    NASA Technical Reports Server (NTRS)

    1979-01-01

    For deepwater operations the self-propelled oil drillship is employed. This type of vessel resembles a cargo ship except for its large derrick, which supports the drilling equipment. Extending from the drillship to the well thousands of feet steel tube usually one to two feet in diameter. The drilling equipment, or drill string, is lowered to the well through this riser. The riser is not rigid nor strictly vertical; it is described by one expert as "a very long piece of spaghetti," held in tension at the well and at the ship end by strong cables. Obviously, the ship must remain often for months-in a position directly over the well. If it were to drift excessively forward, aft or to either side, its movement could snap the riser and disrupt operations at a cost of millions. That's where space technology is playing a part. The same technology employed to locate a spacecraft in orbit and maintain a precise position is applicable to drillship operation. In space, automatic navigation equipment sights on reference points-the Earth, the sun or other stars--to determine spacecraft location. If the space mission requires the spacecraft to hold a certain position, it is accomplished by the firing of computer- directed control thrusters. Two major aerospace companies- Honeywell Inc. and TRW Inc.-have applied their extensive experience in spacecraft positioning and control to the offshore drilling technique known as dynamic positioning, meaning holding the drillship in precise position over the work site.

  19. Report on FY17 testing in support of integrated EPP-SMT design methods development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yanli .; Jetter, Robert I.; Sham, T. -L.

    The goal of the proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology is to incorporate a SMT data-based approach for creep-fatigue damage evaluation into the EPP methodology to avoid the separate evaluation of creep and fatigue damage and eliminate the requirement for stress classification in current methods; thus greatly simplifying evaluation of elevated temperature cyclic service. The purpose of this methodology is to minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed methodology and to verify the applicability of the code rules, thermomechanical tests continued in FY17. Thismore » report presents the recent test results for Type 1 SMT specimens on Alloy 617 with long hold times, pressurization SMT on Alloy 617, and two-bar thermal ratcheting test results on SS316H at the temperature range of 405 °C to 705 °C. Preliminary EPP strain range analysis on the two-bar tests are critically evaluated and compared with the experimental results.« less

  20. Sub-Scale Orion Parachute Test Results from the National Full-Scale Aerodynamics Complex 80- By 120-ft Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Anderson, Brian P.; Greathouse, James S.; Powell, Jessica M.; Ross, James C.; Schairer, Edward T.; Kushner, Laura; Porter, Barry J.; Goulding, Patrick W., II; Zwicker, Matthew L.; Mollmann, Catherine

    2017-01-01

    A two-week test campaign was conducted in the National Full-Scale Aerodynamics Complex 80 x 120-ft Wind Tunnel in support of Orion parachute pendulum mitigation activities. The test gathered static aerodynamic data using an instrumented, 3-tether system attached to the parachute vent in combination with an instrumented parachute riser. Dynamic data was also gathered by releasing the tether system and measuring canopy performance using photogrammetry. Several canopy configurations were tested and compared against the current Orion parachute design to understand changes in drag performance and aerodynamic stability. These configurations included canopies with varying levels and locations of geometric porosity as well as sails with increased levels of fullness. In total, 37 runs were completed for a total of 392 data points. Immediately after the end of the testing campaign a down-select decision was made based on preliminary data to support follow-on sub-scale air drop testing. A summary of a more rigorous analysis of the test data is also presented.

  1. 30. STARBOARD REFUELING STATION STARBOARD LOOKING TO PORT SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    30. STARBOARD REFUELING STATION - STARBOARD LOOKING TO PORT SHOWING RIGGING, FUEL RISER, SHUT-OFF VALVE, TEST COCK AND PRESSURE GAUGE. - U.S.S. HORNET, Puget Sound Naval Shipyard, Sinclair Inlet, Bremerton, Kitsap County, WA

  2. 48. Historic American Buildings Survey, Donald W. Dickensheets, Photographer. March ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    48. Historic American Buildings Survey, Donald W. Dickensheets, Photographer. March 28, 1940. BURNT BRICK. WALLS, ARCH, RISERS, stairway west tower. (WEST ELEVATION). - San Xavier del Bac Mission, Mission Road, Tucson, Pima County, AZ

  3. 5. Historic American Buildings Survey E. W. Russell, Photographer, June ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Historic American Buildings Survey E. W. Russell, Photographer, June 17, 1937 CLOSEUP OF THE LOWER SECTION OF FIRST STORY WINDOW ON FRONT, SHOWING SHUTTER AND HINGE. - Wewoka, Riser Mill Road, Sylacauga, Talladega County, AL

  4. 21. Historic American Buildings Survey, W. Jeter Eason Deputy District ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    21. Historic American Buildings Survey, W. Jeter Eason- Deputy District Officer, Photographer November 21, 1936 DETAIL OF DECORATIVE STAIR RISERS. - The Hermitage, U.S. Highway 70 North (4580 Rachel's Lane), Nashville, Davidson County, TN

  5. Installation of surface-mounted flat-conductor cable

    NASA Technical Reports Server (NTRS)

    Carden, J. R.

    1976-01-01

    Guide describes step-by-step process for installation of interior surface-mounted FCC used in commerical and residential buildings. Photographs illustrate how cable-riser and baseboard covers are installed as well as receptacle assembly and receptacle-cover replacement.

  6. The effects of two different water management regimes on flooding and mosquito production in a salt marsh impoundment.

    PubMed

    Carlson, D B; Vigliano, R R

    1985-06-01

    Over two years, the management regimes of: 1) opening a southeast Florida salt marsh impoundment to the adjacent estuary with culverts through the dike, then, 2) passively retaining water with flapgate risers was studied to determine the effects on marsh flooding and resultant mosquito production. Larval dipping demonstrated that all broods occurred at elevations of 0.25-0.90 ft (= 0.08-0.27 m) NGVD. Mosquito production differed significantly between some sampling quadrats and 65 (out of 75) broods were produced in the spring and summer from rainfall. Without artificial pumping, trapping of rainfall with flapgate risers aided in eliminating oviposition sites but still allowed mosquito production in some marsh locations. Even though tidal flooding permitted larvivorous fish access to mosquito larvae, they were not able to provide adequate control to eliminate larviciding.

  7. MFIX simulation of NETL/PSRI challenge problem of circulating fluidized bed

    DOE PAGES

    Li, Tingwen; Dietiker, Jean-François; Shahnam, Mehrdad

    2012-12-01

    In this paper, numerical simulations of NETL/PSRI challenge problem of circulating fluidized bed (CFB) using the open-source code Multiphase Flow with Interphase eXchange (MFIX) are reported. Two rounds of simulation results are reported including the first-round blind test and the second-round modeling refinement. Three-dimensional high fidelity simulations are conducted to model a 12-inch diameter pilot-scale CFB riser. Detailed comparisons between numerical results and experimental data are made with respect to axial pressure gradient profile, radial profiles of solids velocity and solids mass flux along different radial directions at various elevations for operating conditions covering different fluidization regimes. Overall, the numericalmore » results show that CFD can predict the complex gas–solids flow behavior in the CFB riser reasonably well. In addition, lessons learnt from modeling this challenge problem are presented.« less

  8. Too much FCC catalyst activity can cut yields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wichers, W.R.; Upson, L.

    1984-03-19

    For many people working in the field of catalytic cracking, high equilibrium catalyst activity is inherently good. It is surprising how many times this line of reasoning is accepted by the refiner. There also seems to be something psychologically satisfying in seeing an equilibrium catalyst report where the catalyst activity is reported as a high number. Generally, everyone is happy when the reported activity of equilibrium catalyst is increasing and unhappy when it is going down. In the past, increasing catalyst activity did result in improved operations. For units that operated with substantial amounts of bed cracking, higher activity catalystmore » allowed the amount of bed cracking to be reduced and the relative amount of cracking that occurred in the riser to be increased. The switch from bed to riser cracking decreased catalytic coke make and gasoline overcracking, thus reducing regenerator temperature and improving gasoline yields.« less

  9. Large woody debris and flow resistance in step-pool channels, Cascade Range, Washington

    USGS Publications Warehouse

    Curran, Janet H.; Wohl, Ellen E.

    2003-01-01

    Total flow resistance, measured as Darcy-Weisbach f, in 20 step-pool channels with large woody debris (LWD) in Washington, ranged from 5 to 380 during summer low flows. Step risers in the study streams consist of either (1) large and relatively immobile woody debris, bedrock, or roots that form fixed, or “forced,” steps, or (2) smaller and relatively mobile wood or clasts, or a mixture of both, arranged across the channel by the stream. Flow resistance in step-pool channels may be partitioned into grain, form, and spill resistance. Grain resistance is calculated as a function of particle size, and form resistance is calculated as large woody debris drag. Combined, grain and form resistance account for less than 10% of the total flow resistance. We initially assumed that the substantial remaining portion is spill resistance attributable to steps. However, measured step characteristics could not explain between-reach variations in flow resistance. This suggests that other factors may be significant; the coefficient of variation of the hydraulic radius explained 43% of the variation in friction factors between streams, for example. Large woody debris generates form resistance on step treads and spill resistance at step risers. Because the form resistance of step-pool channels is relatively minor compared to spill resistance and because wood in steps accentuates spill resistance by increasing step height, we suggest that wood in step risers influences channel hydraulics more than wood elsewhere in the channel. Hence, the distribution and function, not just abundance, of large woody debris is critical in steep, step-pool channels.

  10. What you see is what you step: the horizontal-vertical illusion increases toe clearance in older adults during stair ascent.

    PubMed

    Foster, Richard J; Whitaker, David; Scally, Andrew J; Buckley, John G; Elliott, David B

    2015-05-01

    Falls on stairs are a significant cause of morbidity and mortality in elderly people. A simple safety strategy to avoid tripping on stairs is increasing foot clearance. We determined whether a horizontal-vertical illusion superimposed onto stairs to create an illusory perceived increase in stair-riser height would increase stair ascent foot clearance in older participants. Preliminary experiments determined the optimum parameters for the horizontal-vertical illusion. Fourteen older adults (mean age ± 1 SD, 68.5 ± 7.4 years) ascended a three-step staircase with the optimized version of the horizontal-vertical illusion (spatial frequency: 12 cycles per stair riser) positioned either on the bottom or top stair only, or on the bottom and top stair simultaneously. These were compared to a control condition, which had a plain stair riser with edge highlighters positioned flush with each stair-tread edge. Foot clearance and measures of postural stability were compared across conditions. The optimized illusion on the bottom and top stair led to a significant increase in foot clearance over the respective stair edge, compared to the control condition. There were no significant decreases in postural stability. An optimized horizontal-vertical visual illusion led to significant increases in foot clearance in older adults when ascending a staircase, but the effects did not destabilize their postural stability. Inclusion of the horizontal-vertical illusion on raised surfaces (e.g., curbs) or the bottom and top stairs of staircases could improve stair ascent safety in older adults.

  11. Circadian variation of acute aortic dissection.

    PubMed

    Seguchi, Masaru; Wada, Hiroshi; Sakakura, Kenichi; Nakagawa, Tom; Ibe, Tatsuro; Ikeda, Nahoko; Sugawara, Yoshitaka; Ako, Junya; Momomura, Shin-ichi

    2015-05-13

    Acute aortic dissection (AAD) is a life-threatening cardiovascular disease with high mortality. Hypertension is a well known risk factor of AAD. There have been previous reports about the association between circadian variation of blood pressure (BP) and cardiovascular events. However, little is known about the association between the onset-time of AAD and circadian variation of BP. The purpose of this study was to clarify the characteristics of circadian variation of BP in AAD and its relation to the onset-time of this disease. This study included type B spontaneous AAD patients who were referred to our institution and treated conservatively between January 2008 and June 2013. Patients with type A AAD, secondary to trauma, and type B AAD which preceded surgical intervention were excluded. Data were retrospectively collected from the hospital medical records. Sixty-eight patients with type B AAD were enrolled. The distribution of the circadian pattern in the study patients was as follows: extreme-dipper, 0% (none); dipper, 20.6% (n = 14); nondipper, 50% (n = 34); riser, 29.4% (n = 20). Non-dipper and riser patterns were more frequently observed compared with other population studies reported previously. Moreover, no patient in the dipper group had night-time onset while 31.5% of the patients in the absence of nocturnal BP fall group (non-dipper and riser) did (P = 0.01). Absence of a nocturnal BP fall was frequently seen in AAD patients. Absence of a nocturnal BP fall may be a risk factor of AAD. Circadian variation of BP may also affect the onset-time of type B AAD.

  12. 25. MAIN MEETING ROOM STAIRWAY IN SOUTHEAST CORNER. Stairway seen ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    25. MAIN MEETING ROOM STAIRWAY IN SOUTHEAST CORNER. Stairway seen from below showing lath and plaster fireproofing applied to framing before treads and risers. - Twelfth Street Meeting House, 20 South Twelfth Street, Philadelphia, Philadelphia County, PA

  13. 36. Basement, cellar beneath main stairway, with skylight in stair ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. Basement, cellar beneath main stairway, with skylight in stair riser, and adjacent storage room, view to east - Portsmouth Naval Hospital, Hospital Building, Rixey Place, bounded by Williamson Drive, Holcomb Road, & The Circle, Portsmouth, Portsmouth, VA

  14. Early Risers Benefit from Scholars Program.

    ERIC Educational Resources Information Center

    Jackson, Maria L.; Russell, Ernest L.

    1987-01-01

    The 7 O'Clock Scholars Program for gifted and talented students at Pontiac (Michigan) Central Senior High School brings speakers from a nearby university to speak to interested high school students during 50-minute sessions before regular classes begin. (PGD)

  15. Drafting. Advanced Print Reading--Electrical.

    ERIC Educational Resources Information Center

    Oregon State Dept. of Education, Salem.

    This document is a workbook for drafting students learning advanced print reading for electricity applications. The workbook contains seven units covering the following material: architectural working drawings; architectural symbols and dimensions; basic architectural electrical symbols; wiring symbols; riser diagrams; schematic diagrams; and…

  16. Selective Herbicides Reduce Weeding Costs in Two Mississippi Nurseries

    Treesearch

    W. B. Smyly; T. H. Filer

    1979-01-01

    In tests conducted from 1974 to 1977, the preemergence herbicides, Treflan, Eptam, Dymid, and Dectun reduced weeds and weeding costs in seedling beds of loblolly, slash, and short leaf pine. Velpar and Roundup controlled weeds along riser lines.

  17. Development of a Reduced-Order Model for Reacting Gas-Solids Flow using Proper Orthogonal Decomposition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McDaniel, Dwayne; Dulikravich, George; Cizmas, Paul

    2017-11-27

    This report summarizes the objectives, tasks and accomplishments made during the three year duration of this research project. The report presents the results obtained by applying advanced computational techniques to develop reduced-order models (ROMs) in the case of reacting multiphase flows based on high fidelity numerical simulation of gas-solids flow structures in risers and vertical columns obtained by the Multiphase Flow with Interphase eXchanges (MFIX) software. The research includes a numerical investigation of reacting and non-reacting gas-solids flow systems and computational analysis that will involve model development to accelerate the scale-up process for the design of fluidization systems by providingmore » accurate solutions that match the full-scale models. The computational work contributes to the development of a methodology for obtaining ROMs that is applicable to the system of gas-solid flows. Finally, the validity of the developed ROMs is evaluated by comparing the results against those obtained using the MFIX code. Additionally, the robustness of existing POD-based ROMs for multiphase flows is improved by avoiding non-physical solutions of the gas void fraction and ensuring that the reduced kinetics models used for reactive flows in fluidized beds are thermodynamically consistent.« less

  18. Preliminary test results in support of integrated EPP and SMT design methods development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Yanli; Jetter, Robert I.; Sham, T. -L.

    2016-02-09

    The proposed integrated Elastic Perfectly-Plastic (EPP) and Simplified Model Test (SMT) methodology consists of incorporating a SMT data-based approach for creep-fatigue damage evaluation into the EPP methodology to avoid using the creep-fatigue interaction diagram (the D diagram) and to minimize over-conservatism while properly accounting for localized defects and stress risers. To support the implementation of the proposed code rules and to verify their applicability, a series of thermomechanical tests have been initiated. One test concept, the Simplified Model Test (SMT), takes into account the stress and strain redistribution in real structures by including representative follow-up characteristics in the test specimen.more » The second test concept is the two-bar thermal ratcheting tests with cyclic loading at high temperatures using specimens representing key features of potential component designs. This report summaries the previous SMT results on Alloy 617, SS316H and SS304H and presents the recent development on SMT approach on Alloy 617. These SMT specimen data are also representative of component loading conditions and have been used as part of the verification of the proposed integrated EPP and SMT design methods development. The previous two-bar thermal ratcheting test results on Alloy 617 and SS316H are also summarized and the new results from two bar thermal ratcheting tests on SS316H at a lower temperature range are reported.« less

  19. Uncovering a Salt Giant. Deep-Sea Record of Mediterranean Messinian Events (DREAM) multi-phase drilling project

    NASA Astrophysics Data System (ADS)

    Camerlenghi, Angelo; Aoisi, Vanni; Lofi, Johanna; Hübscher, Christian; deLange, Gert; Flecker, Rachel; Garcia-Castellanos, Daniel; Gorini, Christian; Gvirtzman, Zohar; Krijgsman, Wout; Lugli, Stefano; Makowsky, Yizhaq; Manzi, Vinicio; McGenity, Terry; Panieri, Giuliana; Rabineau, Marina; Roveri, Marco; Sierro, Francisco Javier; Waldmann, Nicolas

    2014-05-01

    In May 2013, the DREAM MagellanPlus Workshop was held in Brisighella (Italy). The initiative builds from recent activities by various research groups to identify potential sites to perform deep-sea scientific drilling in the Mediterranean Sea across the deep Messinian Salinity Crisis (MSC) sedimentary record. In this workshop three generations of scientists were gathered: those who participated in formulation of the deep desiccated model, through DSDP Leg 13 drilling in 1973; those who are actively involved in present-day MSC research; and the next generation (PhD students and young post-docs). The purpose of the workshop was to identify locations for multiple-site drilling (including riser-drilling) in the Mediterranean Sea that would contribute to solve the several open questions still existing about the causes, processes, timing and consequences at local and planetary scale of an outstanding case of natural environmental change in the recent Earth history: the Messinian Salinity Crisis in the Mediterranean Sea. The product of the workshop is the identification of the structure of an experimental design of site characterization, riser-less and riser drilling, sampling, measurements, and down-hole analyses that will be the core for at least one compelling and feasible multiple phase drilling proposal. Particular focus has been given to reviewing seismic site survey data available from different research groups at pan-Mediterranean basin scale, to the assessment of additional site survey activity including 3D seismics, and to ways of establishing firm links with oil and gas industry. The scientific community behind the DREAM initiative is willing to proceed with the submission to IODP of a Multi-phase Drilling Project including several drilling proposals addressing specific drilling objectives, all linked to the driving objectives of the MSC drilling and understanding . A series of critical drilling targets were identified to address the still open questions related to the MSC event. Several proposal ideas also emerged to support the Multi-phase drilling project concept: Salt tectonics and fluids, Deep stratigraphic and crustal drilling in the Gulf of Lion (deriving from the GOLD drilling project), Deep stratigraphic and crustal drilling in the Ionian Sea, Deep Biosphere, Sapropels, and the Red Sea. A second MagellanPlus workshop held in January 2014 in Paris (France), has proceeded a step further towards the drafting of the Multi-phase Drilling Project and a set of pre-proposals for submission to IODP.

  20. 36 CFR 1192.117 - Floors, steps and thresholds.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (b) All step edges and thresholds shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark or dark-on-light. ...

  1. 36 CFR 1192.117 - Floors, steps and thresholds.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (b) All step edges and thresholds shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark or dark-on-light. ...

  2. 36 CFR 1192.117 - Floors, steps and thresholds.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (b) All step edges and thresholds shall have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark or dark-on-light. ...

  3. 49 CFR 192.933 - What actions must be taken to address integrity issues?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Transmission Pipeline Integrity Management § 192.933 What actions must be taken to address integrity issues? (a... any indication of metal loss, cracking or a stress riser. (iii) An indication or anomaly that in the...

  4. 49 CFR 192.933 - What actions must be taken to address integrity issues?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Transmission Pipeline Integrity Management § 192.933 What actions must be taken to address integrity issues? (a... any indication of metal loss, cracking or a stress riser. (iii) An indication or anomaly that in the...

  5. 49 CFR 192.933 - What actions must be taken to address integrity issues?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Transmission Pipeline Integrity Management § 192.933 What actions must be taken to address integrity issues? (a... any indication of metal loss, cracking or a stress riser. (iii) An indication or anomaly that in the...

  6. 34. Photographic copy of the Post Engineer drawing (original is ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    34. Photographic copy of the Post Engineer drawing (original is located at Fort Hood) electrical riser plan, plan number PE 1268.2 - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX

  7. Estimation of terracing characteristics from airborne laser scanning data

    NASA Astrophysics Data System (ADS)

    Kokalj, Žiga

    2015-04-01

    Agricultural terraces are a fundamental morphological form of the Slovenian landscape. They are present in all of its diverse geographical regions, from Mediterranean and Dinaric hills and plateaus, Alpine mountains and plains, to Pannonian hills. New systematic research based on mapping aerial orthophotos and historical maps revealed previously unrecorded distribution and extent of terracing. However, the extensive overgrowing of the Slovenian countryside in the past century, when forest cover has grown from 40% to more than 60%, hid many of the terraces under a thick forest canopy. This is especially true for the higher and more remote areas where unfavourable natural conditions have coupled with depopulation processes. In such conditions, the only reasonable technique to observe cultural terraces and other remains of past human activities over large areas is airborne laser scanning. With the country-wide airborne lidar data becoming available, many new possibilities for discovery as well as quantitative analyses are becoming available. We explored manual and semiautomatic approaches to obtain terracing characteristics around representative villages of diverse landscape types. Individual terraces can be described with several attributes, such as riser slope gradient, riser height, tread area, length and width, ratio of length and width, altitude, location of the terrace in the thermal band, distance to the settlement, number and type of trees, distance between trees, and number of vineyard rows. Such characteristics can be derived manually, which can be painstakingly slow, but with relative precisions reaching the order of centimetres and decimetres, or semiautomatically, which is much faster, but with worse precision levels, mainly due to various outliers and errors in processing. The success of attribute derivation is highly dependent on raw lidar data acquisition parameters and processing. Manual interpretation has a distinct advantage of the possibility to explore and manipulate the raw data, i.e. the lidar point cloud, where relevant features that could be removed in the filtering process can still be traced and their exact extents discernible. However, this is only possible for specific and very detailed analyses, while much more of the work has to be done with already processed raster elevation data. Processing has to be tailored specifically with terracing in mind, otherwise typical characteristics, such as riser slope gradient and thread edges can be distorted. We also investigated the role different elevation model visualizations have on the manual interpretation of terraced landscapes and which visualizations can benefit semiautomatic processing.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muhleman, T.; Dempsey, P.

    Although reduced activity has left its mark on engineering budgets and many projects have been delayed, industry remains committed to research and development. This year's emphasis is offshore where new-generation semi-submersibles are under construction for Arctic waters and where equipment technology is reaching maturity. Improved tubulars such as new process-forged drill pipe, special alloy, corrosion-resistant pipe and new tool joint designs are finding eager markets both on and offshore. And back in the office, microcomputers, a curiosity a few years ago, are making significant advances in improving drilling and production operations. Specific examples of this new technology include: Two high-tech,more » high-risk floaters Hard rock sidewall coring tool New torque-resistant tool joint Two improved riser connection systems Breakthrough in drill pipe manufacturing Power-packed portable drilling computer.« less

  9. A New Dry Flue Gas Desulfurization Process-Underfeed Circulating Spouted Bed

    NASA Astrophysics Data System (ADS)

    Tao, M.; Jin, B. S.; Yang, Y. P.

    Applying an underfeed system, the underfeed circulating spouted bed was designed as a desulfurization reactor. The main objective of the technology is to improve the mixing effect and distribution uniformity of solid particles, and therefore to advance the desulfurization efficiency and calcium utility. In this article, a series of experimental studies were conducted to investigate the fluidization behavior of the solid-gas two-phase flow in the riser. The results show that the technology can distinctly improve the distribution of gas velocity and particle flux on sections compared with the facefeed style. Analysis of pressure fluctuation signals indicates that the operation parameters have significant influence on the flow field in the reaction bed. The existence of injecting flow near the underfeed nozzle has an evident effect on strengthening the particle mixing.

  10. Project W-320, 241-C-106 sluicing electrical calculations, Volume 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bailey, J.W.

    1998-08-07

    This supporting document has been prepared to make the FDNW calculations for Project W-320, readily retrievable. These calculations are required: To determine the power requirements needed to power electrical heat tracing segments contained within three manufactured insulated tubing assemblies; To verify thermal adequacy of tubing assembly selection by others; To size the heat tracing feeder and branch circuit conductors and conduits; To size protective circuit breaker and fuses; and To accomplish thermal design for two electrical heat tracing segments: One at C-106 tank riser 7 (CCTV) and one at the exhaust hatchway (condensate drain). Contents include: C-Farm electrical heat tracing;more » Cable ampacity, lighting, conduit fill and voltage drop; and Control circuit sizing and voltage drop analysis for the seismic shutdown system.« less

  11. FInal Report - Investment Casting Shell Cracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Von Richards

    2003-12-01

    This project made a significant contribution to the understanding of the investment casting shell cracking problem. The effects of wax properties on the occurrence of shell cracking were demonstrated and can be measured. The properties measured include coefficient of thermal expansion, heating rate and crystallinity of the structure. The important features of production molds and materials properties have been indicated by case study analysis and fractography of low strength test bars. It was found that stress risers in shell cavity design were important and that typical critical flaws were either oversize particles or large pores just behind the prime coat.more » It was also found that the true effect of fugitive polymer fibers was not permeability increase, but rather a toughening mechanism due to crack deflection.« less

  12. Spin-tunnel investigation of the spinning characteristics of typical single-engine general aviation airplane designs. 2: Low-wing model A; tail parachute diameter and canopy distance for emergency spin recovery

    NASA Technical Reports Server (NTRS)

    Burk, S. M., Jr.; Bowman, J. S., Jr.; White, W. L.

    1977-01-01

    A spin tunnel study is reported on a scale model of a research airplane typical of low-wing, single-engine, light general aviation airplanes to determine the tail parachute diameter and canopy distance (riser length plus suspension-line length) required for energency spin recovery. Nine tail configurations were tested, resulting in a wide range of developed spin conditions, including steep spins and flat spins. The results indicate that the full-scale parachute diameter required for satisfactory recovery from the most critical conditions investigated is about 3.2 m and that the canopy distance, which was found to be critical for flat spins, should be between 4.6 and 6.1 m.

  13. Experimental Study of the Vortex-Induced Vibration of Drilling Risers under the Shear Flow with the Same Shear Parameter at the Different Reynolds Numbers

    PubMed Central

    Liangjie, Mao; Qingyou, Liu; Shouwei, Zhou

    2014-01-01

    A considerable number of studies for VIV under the uniform flow have been performed. However, research on VIV under shear flow is scarce. An experiment for VIV under the shear flow with the same shear parameter at the two different Reynolds numbers was conducted in a deep-water offshore basin. Various measurements were obtained by the fiber bragg grating strain sensors. Experimental data were analyzed by modal analysis method. Results show several valuable features. First, the corresponding maximum order mode of the natural frequency for shedding frequency is the maximum dominant vibration mode and multi-modal phenomenon is appeared in VIV under the shear flow, and multi-modal phenomenon is more apparent at the same shear parameter with an increasing Reynolds number under the shear flow effect. Secondly, the riser vibrates at the natural frequency and the dominant vibration frequency increases for the effect of the real-time tension amplitude under the shear flow and the IL vibration frequency is the similar with the CF vibration frequency at the Reynolds number of 1105 in our experimental condition and the IL dominant frequency is twice the CF dominant frequency with an increasing Reynolds number. In addition, the displacement trajectories at the different locations of the riser appear the same shape and the shape is changed at the same shear parameter with an increasing Reynolds number under the shear flow. The diagonal displacement trajectories are observed at the low Reynolds number and the crescent-shaped displacement trajectories appear with an increasing Reynolds number under shear flow in the experiment. PMID:25118607

  14. Experimental study of the vortex-induced vibration of drilling risers under the shear flow with the same shear parameter at the different Reynolds numbers.

    PubMed

    Liangjie, Mao; Qingyou, Liu; Shouwei, Zhou

    2014-01-01

    A considerable number of studies for VIV under the uniform flow have been performed. However, research on VIV under shear flow is scarce. An experiment for VIV under the shear flow with the same shear parameter at the two different Reynolds numbers was conducted in a deep-water offshore basin. Various measurements were obtained by the fiber bragg grating strain sensors. Experimental data were analyzed by modal analysis method. Results show several valuable features. First, the corresponding maximum order mode of the natural frequency for shedding frequency is the maximum dominant vibration mode and multi-modal phenomenon is appeared in VIV under the shear flow, and multi-modal phenomenon is more apparent at the same shear parameter with an increasing Reynolds number under the shear flow effect. Secondly, the riser vibrates at the natural frequency and the dominant vibration frequency increases for the effect of the real-time tension amplitude under the shear flow and the IL vibration frequency is the similar with the CF vibration frequency at the Reynolds number of 1105 in our experimental condition and the IL dominant frequency is twice the CF dominant frequency with an increasing Reynolds number. In addition, the displacement trajectories at the different locations of the riser appear the same shape and the shape is changed at the same shear parameter with an increasing Reynolds number under the shear flow. The diagonal displacement trajectories are observed at the low Reynolds number and the crescent-shaped displacement trajectories appear with an increasing Reynolds number under shear flow in the experiment.

  15. Influence of slip-surface geometry on earth-flow deformation, Montaguto earth flow, southern Italy

    USGS Publications Warehouse

    Guerriero, L.; Coe, Jeffrey A.; Revellio, P.; Grelle, G.; Pinto, F.; Guadagno, F.

    2016-01-01

    We investigated relations between slip-surface geometry and deformational structures and hydrologic features at the Montaguto earth flow in southern Italy between 1954 and 2010. We used 25 boreholes, 15 static cone-penetration tests, and 22 shallow-seismic profiles to define the geometry of basal- and lateral-slip surfaces; and 9 multitemporal maps to quantify the spatial and temporal distribution of normal faults, thrust faults, back-tilted surfaces, strike-slip faults, flank ridges, folds, ponds, and springs. We infer that the slip surface is a repeating series of steeply sloping surfaces (risers) and gently sloping surfaces (treads). Stretching of earth-flow material created normal faults at risers, and shortening of earth-flow material created thrust faults, back-tilted surfaces, and ponds at treads. Individual pairs of risers and treads formed quasi-discrete kinematic zones within the earth flow that operated in unison to transmit pulses of sediment along the length of the flow. The locations of strike-slip faults, flank ridges, and folds were not controlled by basal-slip surface topography but were instead dependent on earth-flow volume and lateral changes in the direction of the earth-flow travel path. The earth-flow travel path was strongly influenced by inactive earth-flow deposits and pre-earth-flow drainages whose positions were determined by tectonic structures. The implications of our results that may be applicable to other earth flows are that structures with strikes normal to the direction of earth-flow motion (e.g., normal faults and thrust faults) can be used as a guide to the geometry of basal-slip surfaces, but that depths to the slip surface (i.e., the thickness of an earth flow) will vary as sediment pulses are transmitted through a flow.

  16. Development and Testing of a Friction-Based Post-Installable Sensor for Subsea Fiber-Optic Monitoring System

    NASA Technical Reports Server (NTRS)

    Bentley, Nicole L.; Brower, David V.; Le, Suy Q.; Seaman, Calvin H.; Tang, Henry H.

    2017-01-01

    This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system that can be deployed on existing subsea structures. This paper provides a summary of the design concept, prototype development, prototype performance testing, and design refinements of the device. The results of the laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are included in this paper. Limitations of the initial design were identified and future design improvements were proposed. These new features will enhance the coupling of the device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based coupling devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on subsea structures, flowlines or risers. The work described in this paper investigates the design of a friction-based coupling device (friction clamp), which is applicable for pipelines and structures that are suspended in the water column and those that are resting on the seabed. The monitoring elements consist of fiber-optic sensors that are bonded to a metal clamshell with a high-friction coating. The friction clamp has a single hinge design to facilitate the operation of the clamp and dual rows of opposing fasteners to distribute the clamping force on the structure. The friction clamp can be installed by divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology, Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance these technologies that would benefit the environment, the public, and commercial industries.

  17. Development and Testing of a Friction-Based Post-Installable Sensor for Subsea Fiber-Optic Monitoring Systems

    NASA Technical Reports Server (NTRS)

    Bentley, Nicole; Brower, David; Le, Suy Q.; Seaman, Calvin; Tang, Henry

    2017-01-01

    This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system that can be deployed on existing subsea structures. This paper provides a summary of the design concept, prototype development, prototype performance testing, and design refinements of the device. The results of the laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are included in this paper. Limitations of the initial design were identified and future design improvements were proposed. These new features will enhance the coupling of the device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based coupling devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on subsea structures, flowlines or risers. The work described in this paper investigates the design of a friction-based coupling device (friction clamp), which is applicable for pipelines and structures that are suspended in the water column and those that are resting on the seabed. The monitoring elements consist of fiber-optic sensors that are bonded to a metal clamshell with a high-friction coating. The friction clamp has a single hinge design to facilitate the operation of the clamp and dual rows of opposing fasteners to distribute the clamping force on the structure. The friction clamp can be installed by divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology, Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance these technologies that would benefit the environment, the public, and commercial industries.

  18. Void Fraction Instrument operation and maintenance manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Borgonovi, G.; Stokes, T.I.; Pearce, K.L.

    This Operations and Maintenance Manual (O&MM) addresses riser installation, equipment and personnel hazards, operating instructions, calibration, maintenance, removal, and other pertinent information necessary to safely operate and store the Void Fraction Instrument. Final decontamination and decommissioning of the Void Fraction Instrument are not covered in this document.

  19. Mud Gas Logging In A Deep Borehole: IODP Site C0002, Nankai Trough Accretionary Prism

    NASA Astrophysics Data System (ADS)

    Toczko, S.; Hammerschmidt, S.; Maeda, L.

    2014-12-01

    Mud logging, a tool in riser drilling, makes use of the essentially "closed-circuit" drilling mud flow between the drilling platform downhole to the bit and then back to the platform for analyses of gas from the formation in the drilling mud, cuttings from downhole, and a range of safety and operational parameters to monitor downhole drilling conditions. Scientific riser drilling, with coincident control over drilling mud, downhole pressure, and returning drilling mud analyses, has now been in use aboard the scientific riser drilling vessel Chikyu since 2009. International Ocean Discovery Program (IODP) Expedition 348, as part of the goal of reaching the plate boundary fault system near ~5000 mbsf, has now extended the deep riser hole (Hole C0002 N & P) to 3058.5 mbsf. The mud gas data discussed here are from two approximately parallel boreholes, one a kick-off from the other; 860-2329 mbsf (Hole C0002N) and 2163-3058 mbsf (Hole C0002P). An approximate overlap of 166 m between the holes allows for some slight depth comparison between the two holes. An additional 55 m overlap at the top of Hole C0002P exists where a 10-5/8-inch hole was cored, and then opened to 12-1/4-inch with logging while drilling (LWD) tools (Fig. 1). There are several fault zones revealed by LWD data, confirmed in one instance by coring. One of the defining formation characteristics of Holes C0002 N/P are the strongly dipping bedding planes, typically exceeding 60º. These fault zones and bedding planes can influence the methane/ethane concentrations found in the returning drilling mud. A focused comparison of free gas in drilling mud between one interval in Hole C0002 P, drilled first with a 10 5/8-inch coring bit and again with an 12 ¼-inch logging while drilling (LWD) bit is shown. Hole C0002N above this was cased all the way from the sea floor to the kick-off section. A fault interval (in pink) was identified from the recovered core section and from LWD resistivity and gamma. The plot of methane and ethane free gas (C1 and C2; ppmv) shows that the yield of free gas (primarily methane) was greater when the LWD bit returned to open the cored hole to a greater diameter. One possible explanation for this is the time delay between coring and LWD operations; approximately 3 days passed between the end of coring and the beginning of LWD (25-28 December 2013).

  20. 49 CFR 38.79 - Floors, steps and thresholds.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Light Rail Vehicles and Systems § 38.79 Floors, steps and thresholds... have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark or dark-on-light. ...

  1. 49 CFR 38.79 - Floors, steps and thresholds.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Light Rail Vehicles and Systems § 38.79 Floors, steps and thresholds... have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark or dark-on-light. ...

  2. 49 CFR 38.79 - Floors, steps and thresholds.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Light Rail Vehicles and Systems § 38.79 Floors, steps and thresholds... have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark or dark-on-light. ...

  3. 49 CFR 38.79 - Floors, steps and thresholds.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... SPECIFICATIONS FOR TRANSPORTATION VEHICLES Light Rail Vehicles and Systems § 38.79 Floors, steps and thresholds... have a band of color(s) running the full width of the step or threshold which contrasts from the step tread and riser or adjacent floor, either light-on-dark or dark-on-light. ...

  4. Managing farmed closed depressional areas using blind inlets to minimize phosphorus and nitrogen losses

    USDA-ARS?s Scientific Manuscript database

    Through watershed scale research in the St. Joseph River watershed in the United States, farmed potholes have been identified as contributing to nutrient loading of streams. Most farmed potholes are drained with tile risers, which are direct conduits for runoff water and associated contaminants dire...

  5. From Band Rooms to Choral Risers.

    ERIC Educational Resources Information Center

    Washington, William Lee

    1999-01-01

    Offers suggestions for instrumentalists who have become choral instructors explaining that their first goal should be to learn how to identify and understand an ideal vocal sound. Finds that the hardest aspect of choral instruction is developing a teaching approach. Offers five steps to assist instrumentalists in molding their own approach. (CMK)

  6. Evidence for the use of low-grade weirs in drainage ditches to improve nutrient reductions from agriculture

    USDA-ARS?s Scientific Manuscript database

    The essential function of drainage ditches is to remove water from the agricultural landscape to avoid crop senescence through flooding and soil saturation. Commonly used slotted board risers provide drainage management strategies over the dormant season; however, by introducing innovative, low-gra...

  7. A numerical investigation of the scale-up effects on flow, heat transfer, and kinetics processes of FCC units.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, S. L.

    1998-08-25

    Fluid Catalytic Cracking (FCC) technology is the most important process used by the refinery industry to convert crude oil to valuable lighter products such as gasoline. Process development is generally very time consuming especially when a small pilot unit is being scaled-up to a large commercial unit because of the lack of information to aide in the design of scaled-up units. Such information can now be obtained by analysis based on the pilot scale measurements and computer simulation that includes controlling physics of the FCC system. A Computational fluid dynamic (CFD) code, ICRKFLO, has been developed at Argonne National Laboratorymore » (ANL) and has been successfully applied to the simulation of catalytic petroleum cracking risers. It employs hybrid hydrodynamic-chemical kinetic coupling techniques, enabling the analysis of an FCC unit with complex chemical reaction sets containing tens or hundreds of subspecies. The code has been continuously validated based on pilot-scale experimental data. It is now being used to investigate the effects of scaled-up FCC units. Among FCC operating conditions, the feed injection conditions are found to have a strong impact on the product yields of scaled-up FCC units. The feed injection conditions appear to affect flow and heat transfer patterns and the interaction of hydrodynamics and cracking kinetics causes the product yields to change accordingly.« less

  8. Developing a Hydrologic Assessment Tool for Designing Bioretention in a watershed

    NASA Astrophysics Data System (ADS)

    Baek, Sangsoo; Ligaray, Mayzonee; Park, Jeong-Pyo; Kwon, Yongsung; Cho, Kyung Hwa

    2017-04-01

    Continuous urbanization has negatively impacted the ecological and hydrological environments at the global, regional, and local scales. This issue was addressed by developing Low Impact Development (LID) practices to deliver better hydrologic function and improve the environmental, economic, social and cultural outcomes. This study developed a modeling software to simulate and optimize bioretentions among LID in a given watershed. The model calculated a detailed soil infiltration process in bioretention with hydrological conditions and hydraulic facilities (e.g. riser and underdrain) and also generated an optimized plan using Flow Duration Curve (FDC). The optimization result from the simulation demonstrated that the location and size of bioretention, as well as the soil texture, are important elements for an efficient bioretention. We hope that the developed software in this study could be useful for establishing an appropriate scheme of LID installment

  9. Drogue Parachute Effects on the Orion Crew Module Stability

    NASA Technical Reports Server (NTRS)

    Aubuchon, Vanessa V.; Owens, D. Bruce; Fremaux, C. Michael

    2011-01-01

    A forced oscillation test of the Orion Crew Module (CM) was conducted in the Langley 20-Foot Vertical Spin Tunnel. The objective of the test was to quantify the rate damping characteristics of the CM-drogue chute system. Numerous configurations were tested to measure the influence of the chutes on the CM dynamic aerodynamics and, conversely, the influence of the CM on drogue performance. Results show that the CM-drogue system is well-damped at all combinations of frequency, amplitude, and Strouhal number. The wake of the CM significantly reduces the drogue chute riser line force, and the drogues have little upstream influence on the CM aerodynamics. These results are being used to improve simulation model fidelity of CM flight with drogues deployed, which has been identified by the project as key to a successful Orion Critical Design Review.

  10. Prediction of magnitude of minimum horizontal stress from extended leak-off test conducted by the riser vessel CHIKYU

    NASA Astrophysics Data System (ADS)

    Lin, W.; Masago, H.; Yamamoto, K.; Kawamura, Y.; Saito, S.; Kinoshita, M.

    2007-12-01

    By means of introduction of the drilling vessel 'CHIKYU', riser drilling operations using mud fluid will be carried out in NanTroSEIZE Stage 2 for the first time as an oceanic scientific-drilling. For determining drilling operation parameter such as a mud density, a downhole experiment, leak-off test (LOT) or extended leak-off test (XLOT), is going to be implemented next to casing and cementing at each casing shoe during the drilling process. Data of the downhole experiment aimed for operation can also be used for an important scientific application to obtain in-situ stress information which is necessary for various cases of scientific drillings such as seismogenic zone drillings etc. In order to examine feasibility of the application of the LOT or XLOT data, we analyzed an example of XLOT conducted by the riser vessel CHIKYU during its Shimokita shakedown cruise, 2006; and then estimated magnitude of minimum principal stress in horizontal plane, Shmin. Moreover, we will propose the test procedures to possibly improve the quality of stress result from the applications of LOT or XLOT. The XLOT of Shimokita cruise was conducted under following conditions; 1180 m water depth, 525 mbsf (meter below seafloor) depth, 1030 kg/m3 fluid density (seawater) and 80 litter/min injection flow-rate. Estimated magnitude of the Shmin is equal to 18.3 MPa based on the assumption that fracture closure pressure balances with the minimum principal stress perpendicular to the fracture plane. For comparison, the vertical stress magnitude at the depth was estimated from density profile of core samples retrieved from the same borehole; and was equal to 20 MPa approximately. These two values can be considered to be not disagreement. Therefore, we can say that the XLOT data is valuable and practical for estimating the magnitude of minimum horizontal stress. From the viewpoint of determining stress magnitude, the XLOT is more essential rather than the LOT because it might be hardly to obtain reliable Shmin magnitude only by leak-off pressure which is exclusive stress-related parameter obtained from the latter. In addition, implementation of the LOT/XLOT multi-cycles (3 cycles) is preferable if possible. The first cycle with a lower maximum injection pressure is for knowing permeable property of the formation and for examining whether there is pre-existing fracture(s). The second cycle is a normal XLOT; and the third one is the repeat of the second one for confirm the pressure values obtained from the XLOTs.

  11. 30 CFR 250.1709 - What are my well-control fluid requirements?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain approval... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (c) BOP procedures you will use while displacing kill weight fluids, and (d) Procedures you will...

  12. 30 CFR 250.514 - Well-control fluids, equipment, and operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... displace kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (3) BOP procedures you will use while displacing kill-weight fluids, and (4) Procedures you will...

  13. 30 CFR 250.514 - Well-control fluids, equipment, and operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... displace kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (3) BOP procedures you will use while displacing kill-weight fluids, and (4) Procedures you will...

  14. 30 CFR 250.614 - Well-control fluids, equipment, and operations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... device. (d) Before you displace kill-weight fluid from the wellbore and/or riser to an underbalanced... your APM your reasons for displacing the kill-weight fluid and provide detailed step-by-step written... integrity of independent barriers, (3) BOP procedures you will use while displacing kill weight fluids, and...

  15. 30 CFR 250.1709 - What are my well-control fluid requirements?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... kill-weight fluid from the wellbore and/or riser to an underbalanced state, you must obtain approval... displacing the kill-weight fluid and provide detailed step-by-step written procedures describing how you will... barriers, (c) BOP procedures you will use while displacing kill weight fluids, and (d) Procedures you will...

  16. 30 CFR 250.614 - Well-control fluids, equipment, and operations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... device. (d) Before you displace kill-weight fluid from the wellbore and/or riser to an underbalanced... your APM your reasons for displacing the kill-weight fluid and provide detailed step-by-step written... integrity of independent barriers, (3) BOP procedures you will use while displacing kill weight fluids, and...

  17. 30 CFR 250.524 - When am I required to take action from my casing diagnostic test?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... casing diagnostic test; (c) Any well that has demonstrated tubing/casing, tubing/riser, casing/casing... casing diagnostic test? 250.524 Section 250.524 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT... Gas Well-Completion Operations Casing Pressure Management § 250.524 When am I required to take action...

  18. KSC00padig013

    NASA Image and Video Library

    2000-04-22

    KENNEDY SPACE CENTER, FLA. -- At left, a manipulator arm on a one-man submarine demonstrates its ability to cut tangled parachute riser lines and place a Diver Operator Plug (top right) inside a mock solid rocket booster nozzle (center). Known as DeepWorker 2000, the sub is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach the DOP to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program

  19. Fracture mechanics correlation of boron/aluminum coupons containing stress risers

    NASA Technical Reports Server (NTRS)

    Adsit, N. R.; Waszczak, J. P.

    1975-01-01

    The mechanical behavior of boron/aluminum near stress risers has been studied and reported. This effort was directed toward defining the tensile behavior of both unidirectional and (0/ plus or minus 45) boron/aluminum using linear elastic fracture mechanics (LEFM). The material used was 5.6-mil boron in 6061 aluminum, consolidated using conventional diffusion bonding techniques. Mechanical properties are reported for both unidirectional and (0/ plus or minus 45) boron/aluminum, which serve as control data for the fracture mechanics predictions. Three different flawed specimen types were studied. In each case the series of specimens remained geometrically similar to eliminate variations in finite size correction factors. The fracture data from these tests were reduced using two techniques. They both used conventional LEFM methods, but the existence of a characteristic flaw was assumed in one case and not the other. Both the data and the physical behavior of the specimens support the characteristic flaw hypothesis. Cracks were observed growing slowly in the (0/ plus or minus 45) laminates, until a critical crack length was reached at which time catastrophic failure occurred.

  20. KSC-00padig013

    NASA Image and Video Library

    2000-04-22

    KENNEDY SPACE CENTER, FLA. -- At left, a manipulator arm on a one-man submarine demonstrates its ability to cut tangled parachute riser lines and place a Diver Operator Plug (top right) inside a mock solid rocket booster nozzle (center). Known as DeepWorker 2000, the sub is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach the DOP to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program

  1. Pulse pressure and nocturnal fall in blood pressure are predictors of vascular, cardiac and renal target organ damage in hypertensive patients (LOD-RISK study).

    PubMed

    García-Ortiz, Luis; Gómez-Marcos, Manuel A; Martín-Moreiras, Javier; González-Elena, Luis J; Recio-Rodriguez, Jose I; Castaño-Sánchez, Yolanda; Grandes, Gonzalo; Martínez-Salgado, Carlos

    2009-08-01

    To analyse the relationship between various parameters derived from ambulatory blood pressure monitoring (ABPM) and vascular, cardiac and renal target organ damage. A cross-sectional, descriptive study. It included 353 patients with short-term or recently diagnosed hypertension. ABPM, carotid intima-media thickness (IMT), Cornell voltage-duration product (Cornell VDP), glomerular filtration rate and albumin/creatinine ratio to assess vascular, cardiac and renal damage. Two hundred and twenty-three patients (63.2%) were males, aged 56.12+/-11.21 years. The nocturnal fall in blood pressure was 11.33+/-8.41, with a dipper pattern in 49.0% (173), nondipper in 30.3% (107), extreme dipper in 12.7% (45) and riser in 7.9% (28). The IMT was lower in the extreme dipper (0.716+/-0.096 mm) and better in the riser pattern (0.794+/-0.122 mm) (P<0.05). The Cornell VDP and albumin/creatinine ratio were higher in the riser pattern (1818.94+/-1798.63 mm/ms and 140.78+/-366.38 mg/g, respectively) than in the other patterns. In the multivariate analysis after adjusting for age, sex and antihypertensive treatment, with IMT as dependent variable the 24-h pulse pressure (beta = 0.003), with Cornell VDP the rest pulse pressure (beta = 12.04), and with the albumin/creatinine ratio the percentage of nocturnal fall in systolic blood pressure (beta = -3.59), the rest heart rate (beta = 1.83) and the standard deviation of 24-h systolic blood pressure (beta = 5.30) remain within the equation. The estimated pulse pressure with ABPM is a predictor of vascular and cardiac organ damage. The nocturnal fall and the standard deviation in 24-h systolic blood pressure measured with the ABPM is a predictor of renal damage.

  2. Reduction of vortex induced forces and motion through surface roughness control

    DOEpatents

    Bernitsas, Michael M; Raghavan, Kamaldev

    2014-04-01

    Roughness is added to the surface of a bluff body in a relative motion with respect to a fluid. The amount, size, and distribution of roughness on the body surface is controlled passively or actively to modify the flow around the body and subsequently the Vortex Induced Forces and Motion (VIFM). The added roughness, when designed and implemented appropriately, affects in a predetermined way the boundary layer, the separation of the boundary layer, the level of turbulence, the wake, the drag and lift forces, and consequently the Vortex Induced Motion (VIM), and the fluid-structure interaction. The goal of surface roughness control is to decrease/suppress Vortex Induced Forces and Motion. Suppression is required when fluid-structure interaction becomes destructive as in VIM of flexible cylinders or rigid cylinders on elastic support, such as underwater pipelines, marine risers, tubes in heat exchangers, nuclear fuel rods, cooling towers, SPAR offshore platforms.

  3. Elimination of Hot Tears in Steel Castings by Means of Solidification Pattern Optimization

    NASA Astrophysics Data System (ADS)

    Kotas, Petr; Tutum, Cem Celal; Thorborg, Jesper; Hattel, Jesper Henri

    2012-06-01

    A methodology of how to exploit the Niyama criterion for the elimination of various defects such as centerline porosity, macrosegregation, and hot tearing in steel castings is presented. The tendency of forming centerline porosity is governed by the temperature distribution close to the end of the solidification interval, specifically by thermal gradients and cooling rates. The physics behind macrosegregation and hot tears indicate that these two defects also are dependent heavily on thermal gradients and pressure drop in the mushy zone. The objective of this work is to show that by optimizing the solidification pattern, i.e., establishing directional and progressive solidification with the help of the Niyama criterion, macrosegregation and hot tearing issues can be both minimized or eliminated entirely. An original casting layout was simulated using a transient three-dimensional (3-D) thermal fluid model incorporated in a commercial simulation software package to determine potential flaws and inadequacies. Based on the initial casting process assessment, multiobjective optimization of the solidification pattern of the considered steel part followed. That is, the multiobjective optimization problem of choosing the proper riser and chill designs has been investigated using genetic algorithms while simultaneously considering their impact on centerline porosity, the macrosegregation pattern, and primarily on hot tear formation.

  4. Stress and Pore Pressure Measurement in IODP Riser Drilling: An Example from Expedition 319, Kumano Basin offshore SW Honshu, Japan

    NASA Astrophysics Data System (ADS)

    Saffer, D. M.; McNeill, L. C.; Byrne, T. B.; Araki, E.; Flemings, P. B.; Conin, M.; Eguchi, N. O.; Takahashi, K.; Toczko, S.; Boutt, D. F.; Doan, M.; Kano, Y.; Ito, T.; Lin, W.

    2009-12-01

    In summer 2009, Integrated Ocean Drilling Program (IODP) Expedition 319 drilled a 1600 m deep riser borehole (Site C0009) in the Kumano Basin offshore SW Japan, to investigate the properties, structure and state of stress in the hanging wall above the subduction plate boundary. The first riser-based scientific drilling in IODP history allowed us to make several new scientific measurements including in situ stress magnitude, pore pressure and permeability using the Modular Formation Dynamics Tester (MDT) wireline tool, and measurement of minimum stress magnitude from Leak-off Tests (LOT). In addition, continuous monitoring of mud weight, mud gas, annular pressure, and mud losses provided data to constrain formation pore fluid pressure and stress. At Site C0009, we conducted 2 LOTs below a casing shoe at 708.6 m depth and 11 successful MDT measurements, including 9 single probe tests to measure pore pressure and fluid mobility and 2 dual packer tests: 1 to measure permeability by a drawdown test, and 1 to measure in situ stress. Measured pore pressures are approximately hydrostatic to 1463.7 m depth. We observed only minor gas shows when drilling ahead (as in-place methane was liberated from the rock at the bit) but little or no gas during pipe connections. This indicates that the borehole mud pressure exceeded the formation pore pressure, and is consistent with the MDT measurements. Permeabilities range from ~10-16 m2 - 10-14 m2, and the observed variation is consistent with lithologic changes defined in gamma ray logs. The MDT measurement at 874.3 mbsf and the LOT at 708.6 m yield values for the least principal stress of 34.8 MPa and 30.2 MPa, respectively. Both are less than the vertical stress (Sv) computed from density logs. Partial mud circulation losses occurred when the borehole mud pressure exceeded the leak-off stress measured at the base of the casing shoe; this provides an additional indirect constraint on Shmin magnitude. Mud pressure slightly in excess of the leak-off stress may have also generated poorly-developed drilling-induced tensile fractures (DITF) observed in resistivity image logs between ~750 - 1000 m. From the presence of DITF, Shmin measurements, and assuming a rock tensile strength of 1 MPa, we determine that SHmax is 35.1 MPa for the MDT stress measurement, and 30.2 MPa for the LOT. Using the MDT measurement of Shmin, the resulting principal stress magnitudes define a strike-slip faulting regime with effective stresses of Shmax’ = 14 MPa, Sv' = 7.3 MPa, and Shmin’ = 6.4 MPa. In contrast, using the LOT measurement of Shmin, the stress magnitudes indicate a normal faulting regime in which Sv’ = 6.2 MPa, Shmax’ = 2.8 MPa, and Shmin’ = 2.6 MPa.

  5. New mud gas monitoring system aboard D/V Chikyu

    NASA Astrophysics Data System (ADS)

    Kubo, Yusuke; Inagaki, Fumio; Eguchi, Nobuhisa; Igarashi, Chiaki

    2013-04-01

    Mud gas logging has been commonly used in oil industry and continental scientific drilling to detect mainly hydrocarbon gases from the reservoir formation. Quick analysis of the gas provides almost real-time information which is critical to evaluate the formation and, in particular, safety of drilling operation. Furthermore, mud gas monitoring complements the lack of core or fluid samples particularly in a deep hole, and strengthen interpretations of geophysical logs. In scientific ocean drilling, on the other hand, mud gas monitoring was unavailable in riserless drilling through the history of DSDP and ODP, until riser drilling was first carried out in 2009 by D/V Chikyu. In IODP Exp 319, GFZ installed the same system with that used in continental drilling aboard Chikyu. High methane concentrations are clearly correlated with increased wood content in the cuttings. The system installation was, however, temporary and gas separator was moved during the expedition for a technical reason. In 2011, new mud gas monitoring system was installed aboard Chikyu and was used for the first time in Exp 337. The gas separator was placed on a newly branched bypass mud flow line, and the gas sample was sent to analysis unit equipped with methane carbon isotope analyzer in addition to mass spectrometer and gas chromatograph. The data from the analytical instruments is converted to depth profiles by calculating the lag effects due to mud circulation. Exp 337 was carried out from July 26 to Sep 30, 2011, at offshore Shimokita peninsula, northeast Japan, targeting deep sub-seafloor biosphere in and around coal bed. Data from the hole C0020A, which was drilled to 2466 mbsf with riser drilling, provided insights into bio-geochemical process through the depth of the hole. In this presentation, we show the design of Chikyu's new mud gas monitoring system, with preliminary data from Exp 337.

  6. Commercial Submersible Mixing Pump For SRS Tank Waste Removal - 15223

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hubbard, Mike; Herbert, James E.; Scheele, Patrick W.

    The Savannah River Site Tank Farms have 45 active underground waste tanks used to store and process nuclear waste materials. There are 4 different tank types, ranging in capacity from 2839 m 3 to 4921 m 3 (750,000 to 1,300,000 gallons). Eighteen of the tanks are older style and do not meet all current federal standards for secondary containment. The older style tanks are the initial focus of waste removal efforts for tank closure and are referred to as closure tanks. Of the original 51 underground waste tanks, six of the original 24 older style tanks have completed waste removalmore » and are filled with grout. The insoluble waste fraction that resides within most waste tanks at SRS requires vigorous agitation to suspend the solids within the waste liquid in order to transfer this material for eventual processing into glass filled canisters at the Defense Waste Processing Facility (DWPF). SRS suspends the solid waste by use of recirculating mixing pumps. Older style tanks generally have limited riser openings which will not support larger mixing pumps, since the riser access is typically 58.4 cm (23 inches) in diameter. Agitation for these tanks has been provided by four long shafted standard slurry pumps (SLP) powered by an above tank 112KW (150 HP) electric motor. The pump shaft is lubricated and cooled in a pressurized water column that is sealed from the surrounding waste in the tank. Closure of four waste tanks has been accomplished utilizing long shafted pump technology combined with heel removal using multiple technologies. Newer style waste tanks at SRS have larger riser openings, allowing the processing of waste solids to be accomplished with four large diameter SLPs equipped with 224KW (300 HP) motors. These tanks are used to process the waste from closure tanks for DWPF. In addition to the SLPs, a 224KW (300 HP) submersible mixer pump (SMP) has also been developed and deployed within older style tanks. The SMPs are product cooled and product lubricated canned motor pumps designed to fit within available risers and have significant agitation capabilities to suspend waste solids. Waste removal and closure of two tanks has been accomplished with agitation provided by 3 SMPs installed within the tanks. In 2012, a team was assembled to investigate alternative solids removal technologies to support waste removal for closing tanks. The goal of the team was to find a more cost effective approach that could be used to replace the current mixing pump technology. This team was unable to identify an alternative technology outside of mixing pumps to support waste agitation and removal from SRS waste tanks. However, the team did identify a potentially lower cost mixing pump compared to the baseline SLPs and SMPs. Rather than using the traditional procurement using an engineering specification, the team proposed to seek commercially available submersible mixer pumps (CSMP) as alternatives to SLPs and SMPs. SLPs and SMPs have a high procurement cost and the actual cost of moving pumps between tanks has shown to be significantly higher than the original estimates that justified the reuse of SMPs and SLPs. The team recommended procurement of “off-the-shelf” industry pumps which may be available for significant savings, but at an increased risk of failure and reduced operating life in the waste tank. The goal of the CSMP program is to obtain mixing pumps that could mix from bulk waste removal through tank closure and then be abandoned in place as part of tank closure. This paper will present the development, progress and relative advantages of the CSMP.« less

  7. Hydrodynamic characteristics and overall volumetric oxygen transfer coefficient of a new multi-environment bioreactor.

    PubMed

    Behzadian, Farnaz; Yerushalmi, Laleh; Alimahmoodi, Mahmood; Mulligan, Catherine N

    2013-08-01

    The hydrodynamic characteristics and the overall volumetric oxygen transfer coefficient of a new multi-environment bioreactor which is an integrated part of a wastewater treatment system, called BioCAST, were studied. This bioreactor contains several zones with different environmental conditions including aerobic, microaerophilic and anoxic, designed to increase the contaminant removal capacity of the treatment system. The multi-environment bioreactor is designed based on the concept of airlift reactors where liquid is circulated through the zones with different environmental conditions. The presence of openings between the aerobic zone and the adjacent oxygen-depleted microaerophilic zone changes the hydrodynamic properties of this bioreactor compared to the conventional airlift designs. The impact of operating and process parameters, notably the hydraulic retention time (HRT) and superficial gas velocity (U(G)), on the hydrodynamics and mass transfer characteristics of the system was examined. The results showed that liquid circulation velocity (V(L)), gas holdup (ε) and overall volumetric oxygen transfer coefficient (k(L)a(L)) increase with the increase of superficial gas velocity (U(G)), while the mean circulation time (t(c)) decreases with the increase of superficial gas velocity. The mean circulation time between the aerobic zone (riser) and microaerophilic zone (downcomer) is a stronger function of the superficial gas velocity for the smaller openings (1/2 in.) between the two zones, while for the larger opening (1 in.) the mean circulation time is almost independent of U(G) for U(G) ≥ 0.023 m/s. The smaller openings between the two zones provide higher mass transfer coefficient and better zone generation which will contribute to improved performance of the system during treatment operations.

  8. 75 FR 32273 - Safety Zone; DEEPWATER HORIZON at Mississippi Canyon 252 Outer Continental Shelf MODU in the Gulf...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... establishing a continued safety zone around the riser for the DEEPWATER HORIZON, a Mobile Offshore Drilling... sinking of the DEEPWATER HORIZON, a Mobile Offshore Drilling Unit (MODU), near Mississippi Canyon 252 with... read as follows: Sec. 147.T08-849 DEEPWATER HORIZON Mobile Offshore Drilling Unit Safety Zone. (a...

  9. 30 CFR 250.520 - When do I have to perform a casing diagnostic test?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 2 2011-07-01 2011-07-01 false When do I have to perform a casing diagnostic test? 250.520 Section 250.520 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT, REGULATION, AND... plus 100 psig measured at the subsea wellhead. (3) hybrid well, a riser or the production casing...

  10. 75 FR 42476 - Petition for Waiver of Compliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-21

    ... standard. GLC states that the armrest is attached to a metal riser, which is attached to the metal seat... separated by metal from other vehicle parts, and there are no combustible materials within four feet of the armrest. It is unlikely that this armrest could contribute to flame or smoke unless there is a major fire...

  11. 30 CFR 250.528 - What must I include in my casing pressure request?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... calculated MAWOPs; (h) All casing/riser pre-bleed down pressures; (i) Shut-in tubing pressure; (j) Flowing tubing pressure; (k) Date and the calculated daily production rate during last well test (oil, gas, basic...); (m) Well type (dry tree, hybrid, or subsea); (n) Date of diagnostic test; (o) Well schematic; (p...

  12. 30 CFR 250.527 - What must I include in my casing pressure request?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... calculated MAWOPs; (h) All casing/riser pre-bleed down pressures; (i) Shut-in tubing pressure; (j) Flowing tubing pressure; (k) Date and the calculated daily production rate during last well test (oil, gas, basic...); (m) Well type (dry tree, hybrid, or subsea); (n) Date of diagnostic test; (o) Well schematic; (p...

  13. 30 CFR 250.528 - What must I include in my casing pressure request?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... calculated MAWOPs; (h) All casing/riser pre-bleed down pressures; (i) Shut-in tubing pressure; (j) Flowing tubing pressure; (k) Date and the calculated daily production rate during last well test (oil, gas, basic...); (m) Well type (dry tree, hybrid, or subsea); (n) Date of diagnostic test; (o) Well schematic; (p...

  14. Gentle arrester for moving bodies

    NASA Technical Reports Server (NTRS)

    Hull, R. A.

    1981-01-01

    Wire cable absorbs energy at constant rate with reduced shock and rebounding. Cable typically elongates to 90 percent of its potential, but is surrounded by braided sheath to absorb remaining energy should it break prematurely. Applications of arrester include passenger restraint in air and land vehicles, parachute risers, and ground snatch by aircraft. Possible cable material is type 302 stainless steel.

  15. Best Practices: Pass the Poetry

    ERIC Educational Resources Information Center

    Bafumo, Mary Ellen

    2005-01-01

    Sharing poetry with your students will lead to a lifetime benefit of appreciating the written word If you're an early riser and listen to public radio, you've probably heard Garrison Keillor, the host of "Prairie Home Companion," sharing a reading from the latest edition of "Pretty Good Poems." Each poem invariably evokes a reaction; whether it's…

  16. Secondary Classroom Teachers' Views on Inclusion. WCER Working Paper No. 2003-4

    ERIC Educational Resources Information Center

    King, M. Bruce; Youngs, Peter

    2003-01-01

    Since the fall of 1999, the Research Institute on Secondary Education Reform for Youth with Disabilities (RISER) has studied inclusion and instructional reform in four U.S. secondary schools. This article analyzes general education teachers' views on (a) inclusion and its impact on their teaching and their students and (b) the extent to which…

  17. Nylon shock absorber prevents injury to parachute jumpers

    NASA Technical Reports Server (NTRS)

    Mandel, J. A.

    1966-01-01

    Nylon shock absorbers reduce the canopy-opening shock of a parachute to a level that protects the wearer from injury. A shock absorber is mounted on each of the four risers between the shroud lines and the harness. Because of their size and location, they pose no problem in repacking the chute and harness after a jump.

  18. Evolutionary Steps: A Stairway-Created Display of the History of Life.

    ERIC Educational Resources Information Center

    Hedeen, Stanley E.

    1997-01-01

    Describes an exercise whereby a biology class used a stairway to illustrate how fossiliferous rock strata were deposited, the oldest on the bottom and most recent at the top. Each step represents a dated boundary between adjacent geological ages, and each riser is labeled as a geological unit. Geological time is compressed to 365 days. Offers…

  19. Early Risers

    ERIC Educational Resources Information Center

    Asquith, Chistina

    2002-01-01

    In this article, the author features Bard High School Early College, the first public school in the country to offer a free, full-time college curriculum--and all the credits that go with it--to high schoolers. In Bard's four-year program, students race through high school requirements in 9th and 10th grades, then take college courses in 11th and…

  20. Development and Testing of a Friction-Based Post-Installable Fiber-Optic Monitoring System for Subsea Applications

    NASA Technical Reports Server (NTRS)

    Bentley, Nicole L.; Brower, David V.; Le, Suy Q.; Seaman, Calvin H.; Tang, Henry H.

    2017-01-01

    This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system capable of measuring pressure, strain, and temperature that can be deployed on existing subsea structures. A summary is provided of the design concept, prototype development, prototype performance testing, and subsequent design refinements of the device. The results of laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are also included. Limitations of the initial concept were identified during testing and future design improvements were proposed and later implemented. These new features enhance the coupling of the sensor device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on flowlines, risers, and other subsea structures. The work described in this paper investigates the design and test of a friction-based coupling device (herein referred to as a friction clamp) which is suitable for pipelines and structures that are suspended in the water column as well as for those that are resting on the seabed. The monitoring elements consist of fiberoptic sensors that are bonded to a stainless steel clamshell assembly with a high-friction surface coating. The friction clamp incorporates a single hinge design to facilitate installation of the clamp and dual rows of opposing fasteners to distribute the clamping force along the structure. The friction clamp can be modified to be installed by commercial divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance technologies that will benefit the environment, the public, and commercial industries.

  1. An approach for modeling thermal destruction of hazardous wastes in circulating fluidized bed incinerator.

    PubMed

    Patil, M P; Sonolikar, R L

    2008-10-01

    This paper presents a detailed computational fluid dynamics (CFD) based approach for modeling thermal destruction of hazardous wastes in a circulating fluidized bed (CFB) incinerator. The model is based on Eular - Lagrangian approach in which gas phase (continuous phase) is treated in a Eularian reference frame, whereas the waste particulate (dispersed phase) is treated in a Lagrangian reference frame. The reaction chemistry hasbeen modeled through a mixture fraction/ PDF approach. The conservation equations for mass, momentum, energy, mixture fraction and other closure equations have been solved using a general purpose CFD code FLUENT4.5. Afinite volume method on a structured grid has been used for solution of governing equations. The model provides detailed information on the hydrodynamics (gas velocity, particulate trajectories), gas composition (CO, CO2, O2) and temperature inside the riser. The model also allows different operating scenarios to be examined in an efficient manner.

  2. Quick-Connect, Self-Alining Latch

    NASA Technical Reports Server (NTRS)

    Burns, G. C.; Williams, E. J.

    1983-01-01

    Sturdy latch tolerates 10 degrees of angular mismatch in joining structural elements. Hexagonal passive plate nests in active plate, guided by capture plates and alinement keys and grooves. Center hole in both active and passive plates is 1 meter in diameter. Latch has possible uses a pipe joint, connector for parts of portable structures, and fitting for marine risers on offshore drilling rigs.

  3. 49 CFR 38.25 - Doors, steps and thresholds.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... lift platforms shall have a band of color(s) running the full width of the step or edge which contrasts from the step tread and riser, or lift or ramp surface, either light-on-dark or dark-on-light. (c) Door... opening and the raised lift platform, or highest point of a ramp, shall be a minimum of 68 inches. For...

  4. 49 CFR 38.25 - Doors, steps and thresholds.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... lift platforms shall have a band of color(s) running the full width of the step or edge which contrasts from the step tread and riser, or lift or ramp surface, either light-on-dark or dark-on-light. (c) Door... opening and the raised lift platform, or highest point of a ramp, shall be a minimum of 68 inches. For...

  5. Keep Laptop Cool with Simple Custom Riser

    ERIC Educational Resources Information Center

    Rynone, William

    2012-01-01

    Although the author's netbook computer--a diminished capacity laptop computer--uses less power than its big brother, when working with it on his lap, his thighs are roasted, even in the winter. When using the unit on a flat surface, such as a table top, the bottom surface of the computer and table top become quite warm--and it is generally…

  6. Classroom Teachers' Views on Inclusion. Research Institute on Secondary Education Reform for Youth with Disabilities (RISER) Brief.

    ERIC Educational Resources Information Center

    King, M. Bruce; Youngs, Peter

    This brief discusses the outcomes of a study that examined the views of 32 secondary education teachers in four secondary schools on the inclusion of students with disabilities in their classrooms. Analyses of the interview data indicate that the general education teachers were committed to inclusion and that they did make instructional…

  7. 77 FR 12281 - Williston Basin Interstate Pipeline Company; Notice of Request Under Blanket Authorization

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-29

    ... Natural Gas Act (NGA) as amended, to permanently operate a mainline natural gas sales tap located in... Commission and open to public inspection. \\1\\ 30 FERC ] 61,143 (1985). The new sales tap was installed as an... Commission's Regulations. The sales tap installation included a steel pipe riser with a shut-in valve and...

  8. A new one-man submarine is tested as vehicle for solid rocket booster retrieval

    NASA Technical Reports Server (NTRS)

    2000-01-01

    At left, a manipulator arm on a one-man submarine demonstrates its ability to cut tangled parachute riser lines and place a Diver Operator Plug (top right) inside a mock solid rocket booster nozzle (center). Known as DeepWorker 2000, the sub is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach the DOP to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.

  9. Study of Pressure Oscillations in Supersonic Parachute

    NASA Astrophysics Data System (ADS)

    Dahal, Nimesh; Fukiba, Katsuyoshi; Mizuta, Kazuki; Maru, Yusuke

    2018-04-01

    Supersonic parachutes are a critical element of planetary mission whose simple structure, light-weight characteristics together with high ratio of aerodynamic drag makes them the most suitable aerodynamic decelerators. The use of parachute in supersonic flow produces complex shock/shock and wake/shock interaction giving rise to dynamic pressure oscillations. The study of supersonic parachute is difficult, because parachute has very flexible structure which makes obtaining experimental pressure data difficult. In this study, a supersonic wind tunnel test using two rigid bodies is done. The wind tunnel test was done at Mach number 3 by varying the distance between the front and rear objects, and the distance of a bundle point which divides suspension lines and a riser. The analysis of Schlieren movies revealed shock wave oscillation which was repetitive and had large pressure variation. The pressure variation differed in each case of change in distance between the front and rear objects, and the change in distance between riser and the rear object. The causes of pressure oscillation are: interaction of wake caused by front object with the shock wave, fundamental harmonic vibration of suspension lines, interference between shock waves, and the boundary layer of suspension lines.

  10. Active tectonics in southern Xinjiang, China: Analysis of terrace riser and normal fault scarp degradation along the Hotan-Qira fault system

    NASA Technical Reports Server (NTRS)

    Avouac, Jean-Philippe; Peltzer, Gilles

    1993-01-01

    The northern piedmont of the western Kunlun mountains (Xinjiang, China) is marked at its easternmost extremity, south of the Hotan-Qira oases, by a set of normal faults trending N50E for nearly 70 km. Conspicuous on Landsat and SPOT images, these faults follow the southeastern border of a deep flexural basin and may be related to the subsidence of the Tarim platform loaded by the western Kunlun northward overthrust. The Hotan-Qira normal fault system vertically offsets the piedmont slope by 70 m. Highest fault scarps reach 20 m and often display evidence for recent reactivations about 2 m high. Successive stream entrenchments in uplifted footwallls have formed inset terraces. We have leveled topographic profiles across fault scarps and transverse abandoned terrace risers. The state of degradation of each terrace edge has been characterized by a degradation coefficient tau, derived by comparison with analytical erosion models. Edges of highest abandoned terraces yield a degradation coefficient of 33 +/- 4 sq.m. Profiles of cumulative fault scarps have been analyzed in a similar way using synthetic profiles generated with a simple incremental fault scarp model.

  11. Statistics of velocity fluctuations of Geldart A particles in a circulating fluidized bed riser

    DOE PAGES

    Vaidheeswaran, Avinash; Shaffer, Franklin; Gopalan, Balaji

    2017-11-21

    Here, the statistics of fluctuating velocity components are studied in the riser of a closed-loop circulating fluidized bed with fluid catalytic cracking catalyst particles. Our analysis shows distinct similarities as well as deviations compared to existing theories and bench-scale experiments. The study confirms anisotropic and non-Maxwellian distribution of fluctuating velocity components. The velocity distribution functions (VDFs) corresponding to transverse fluctuations exhibit symmetry, and follow a stretched-exponential behavior up to three standard deviations. The form of the transverse VDF is largely determined by interparticle interactions. The tails become more overpopulated with an increase in particle loading. The observed deviations from themore » Gaussian distribution are represented using the leading order term in the Sonine expansion, which is commonly used to approximate the VDFs in kinetic theory for granular flows. The vertical fluctuating VDFs are asymmetric and the skewness shifts as the wall is approached. In comparison to transverse fluctuations, the vertical VDF is determined by the local hydrodynamics. This is an observation of particle velocity fluctuations in a large-scale system and their quantitative comparison with the Maxwell-Boltzmann statistics.« less

  12. Controlling thermal properties of dense gas fluidized beds for concentrated solar power by internal and external solids circulation

    NASA Astrophysics Data System (ADS)

    Ammendola, Paola; Bareschino, Piero; Chirone, Riccardo; Salatino, Piero; Solimene, Roberto

    2017-06-01

    Fluidization technology displays a long record of success stories, mostly related to applications to thermal and thermochemical processes, which are fostering extension to novel and relatively unexplored fields. Application of fluidized beds to collection and thermal storage of solar radiation in Concentrated Solar Power (CSP) is one of the most promising, a field which poses challenging issues and great opportunities to fluidization scientists and technologists. The potential of this growing field calls for reconsideration of some of the typical design and operation guidelines and criteria, with the goal of exploiting the inherently good thermal performances of gas-fluidized beds at their best. "Creative" and non-conventional design and operation of fluidized beds, like those based on internal and external solids circulation, may be beneficial to the enhancement of thermal diffusivity and surface-to-bed heat transfer, improving the potential for application in the very demanding context of CSP with thermal energy storage. This paper investigated: i) a fluidized bed configuration with an uneven distribution of the fluidizing gas to promote vortices in the scale of bed height (internal solids circulation); ii) a dual fluidized bed configuration characterized by an external solids circulation achieved by the operation of a riser and a bubbling fluidized bed. CFD simulations showed the hydrodynamics conditions under which the internal solids circulation was established. The hydrodynamic characterization of the external solids circulation was achieved by an experimental study carried out with different cold models. The dual fluidized bed system was optimized in terms of operating conditions and geometrical features of the connections between two fluidized beds.

  13. Effects of environmental changes in a stair climbing intervention: generalization to stair descent.

    PubMed

    Webb, Oliver J; Eves, Frank F

    2007-01-01

    Visual improvements have been shown to encourage stair use in worksites independently of written prompts. This study examined whether visual modifications alone can influence behavior in a shopping mall. Climbing one flight of stairs, however, will not confer health benefits. Therefore, this study also assessed whether exposure to the intervention encouraged subsequent stair use. Interrupted time-series design. Escalators flanked by a staircase on either side. Ascending and descending pedestrians (N = 81,948). Following baseline monitoring, a colorful design was introduced on the stair risers of one staircase (the target staircase). A health promotion message was superimposed later on top. The intervention was visible only to ascending pedestrians. Thus, any rise in descending stair use would indicate increased intention to use stairs, which endured after initial exposure to the intervention. Observers inconspicuously coded pedestrians' means of ascent/descent and demographic characteristics. The design alone had no meaningful impact. Addition of the message, however, increased stair climbing at the target and nontarget staircases by 190% and 52%, respectively. The message also produced a modest increase in stair descent at the target (25%) and nontarget (9%) staircases. In public venues, a message component is critical to the success of interventions. In addition, it appears that exposure to an intervention can encourage pedestrians to use stairs on a subsequent occasion.

  14. Late Glacial and Holocene Fire History From Radiocarbon Dating of Charcoal in Valley-Bottom Sediments in Small Watersheds of the Oregon Coast Range

    NASA Astrophysics Data System (ADS)

    Lancaster, S. T.; Frueh, W. T.

    2011-12-01

    A large number (N = 351) of radiocarbon dates of charcoal from valley-bottom sediments in headwater valleys of the southern Oregon Coast Range provides the basis for a new index of fire frequency during the past 17,000 years in this steep landscape covered by dense coniferous forest. Study areas were chosen for their relative lack of recent forest disturbance by harvest or fire, and sampling of stream banks and terrace risers was random, weighted by deposit volume and bank or riser area. This sampling methodology was designed to characterize sediment residence times within valley-bottom storage, and the overall shape of the calibrated age distribution is therefore assumed representative of the dependence of charcoal preservation probability on calibrated age. A proxy record of fire history in the study areas is obtained by fitting a gamma distribution to the weighted mean calibrated charcoal ages by the method of moments; calculating the relative difference between the fit and the normalized histogram, with 50-year bin-widths, of charcoal ages; and smoothing that relative difference with a gaussian distribution, the standard deviation of which is at least two bin-widths and inversely proportional to the value of the fit distribution at larger ages. The calibrated charcoal age mean and variance of 1900 yrs BP and 7.39 x 106 yr2, respectively, yield shape and scale parameters of the fit gamma distribution of 0.490 and 3880 yrs, respectively. This heavy-tailed distribution indicates that probabilities of charcoal evacuation are not simply proportional to relative volume of encasing sediment deposits but, rather, decrease with deposit age. The smoothed proxy record of relative fire frequency has a global maximum at 7700 BP and prominent local maxima at 600 BP and 5700 BP, in order of decreasing magnitude; a global minimum at 4500 BP and local minimum at 1800 BP roughly bracket a period of fluctuating but relatively low fire frequency during the period 5000-1500 BP. Although resolution in the late glacial to early Holocene is limited, the record shows a high relative fire frequency during the late glacial before dipping 10,000-9000 BP. The 7700 BP maximum and 1800 BP minimum are consistent with another fire history from lake sediments northeast of our sites in the Oregon Coast Range. Other features appear to contradict that record but to support of climate change inferences based on other climate proxies.

  15. Apollo 15 mission main parachute failure

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The failure of one of the three main parachutes of the Apollo 15 spacecraft was investigated by studying malfunctions in the forward heat shield, broken riser, and firing the fuel expelled from the command module reaction control system. It is concluded that the most probable cause was the burning of raw fuel being expelled during the latter portion of depletion firing. Recommended corrective actions are included.

  16. Photocopy of drawing (this photograph is an 8" x 10" ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Photocopy of drawing (this photograph is an 8" x 10" copy of an 8" x 10" negative; 1963 original architectural drawing located at Building No. 458, NAS Pensacola, Florida) QUARTERS 5, NEW ELECTRIC SERVICE, NEW MAIN DISTRIBUTION PANEL AND NEW RISER DIAGRAM, ELECTRICAL PLAN, SHEET 1 OF 1 - U.S. Naval Air Station, Senior Officers' Quarters, Q-5 North Avenue, Pensacola, Escambia County, FL

  17. Study of the Dynamics of a Pressurized Reactor as Integral Unit for Naval Propulsion; STUDIO DELLA DINAMICA DI UN REATTORE PRESSURIZZATO AD UNITA INTEGRALE PER PROPULSIONE NAVALE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilardi, E.; Cimorelli, L.

    1963-07-01

    The dynamic behavior of an integrated, pressurizedwater reactor with natural circulation was investigated both by analog computer techniques and a simplified analytical approach. Hydraulic instabilities due to the core or riser were considered, as well as overall stability and problems arising from heavy sea conditions. (auth)

  18. Discussion-preliminary review of the safety aspects of the crossunder line, Project CG-884. Volume 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, S.S.

    1960-12-19

    In order to reduce both charge-discharge shutdown time and the number of manhours of radiation exposure, Project CGI-884 is being completed at the B, D, DR, F and R Reactors. This consists essentially of installing a large drain line at the bottom of one rear reactor riser. This drain line passes to a control valve and then to the effluent line beyond the downcomer. This system by-passes the crossover downcomer part of the effluent system and eliminates the need for intermittent rear crossheader valving during reactor charge-discharge procedures. Two aspects of this system have been considered, its basic design requirements,more » and operating restrictions to ensure adequate process tube cooling. Because of the complexity of the reactor flow system approximate solutions were used to compare different methods or degrees of operation and establish limits. Despite these approximations, there was sufficient difference in the case results to justify the specific conclusions presented in this report. This report should serve the dual purpose of providing design requirements for the crossunder and also providing the technical criteria necessary for the operating standards for the use of this new system.« less

  19. Low-Speed Flight Dynamic Tests and Analysis of the Orion Crew Module Drogue Parachute System

    NASA Technical Reports Server (NTRS)

    Hahne, David E.; Fremaux, C. Michael

    2008-01-01

    A test of a dynamically scaled model of the NASA Orion Crew Module (CM) with drogue parachutes was conducted in the NASA-Langley 20-Foot Vertical Spin Tunnel. The primary test objective was to assess the ability of the Orion Crew Module drogue parachute system to adequately stabilize the CM and reduce angular rates at low subsonic Mach numbers. Two attachment locations were tested: the current design nominal and an alternate. Experimental results indicated that the alternate attachment location showed a somewhat greater tendency to attenuate initial roll rate and reduce roll rate oscillations than the nominal location. Comparison of the experimental data to a Program To Optimize Simulated Trajectories (POST II) simulation of the experiment yielded results for the nominal attachment point that indicate differences between the low-speed pitch and yaw damping derivatives in the aerodynamic database and the physical model. Comparisons for the alternate attachment location indicate that riser twist plays a significant role in determining roll rate attenuation characteristics. Reevaluating the impact of the alternate attachment points using a simulation modified to account for these results showed significantly reduced roll rate attenuation tendencies when compared to the original simulation. Based on this modified simulation the alternate attachment point does not appear to offer a significant increase in allowable roll rate over the nominal configuration.

  20. Cold air systems: Sleeping giant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    MacCracken, C.D.

    1994-04-01

    This article describes how cold air systems help owners increase the profits from their buildings by reducing electric costs and improving indoor air quality through lower relative humidity levels. Cold air distribution involves energy savings, cost savings, space savings, greater comfort, cleaner air, thermal storage, tighter ducting, coil redesign, lower relative humidities, retrofitting, and improved indoor air quality (IAQ). It opens a door for architects, engineers, owners, builders, environmentalists, retrofitters, designers, occupants, and manufacturers. Three things have held up cold air's usage: multiple fan-powered boxes that ate up the energy savings of primary fans. Cold air room diffusers that providedmore » inadequate comfort. Condensation from ducts, boxes, and diffusers. Such problems have been largely eliminated through research and development by utilities and manufacturers. New cold air diffusers no longer need fan powered boxes. It has also been found that condensation is not a concern so long as the ducts are located in air conditioned space, such as drop ceilings or central risers, where relative humidity falls quickly during morning startup.« less

  1. Modular femoral component for conversion of previous hip surgery in total hip arthroplasty.

    PubMed

    Goldstein, Wayne M; Branson, Jill J

    2005-09-01

    The conversion of previous hip surgery to total hip arthroplasty creates a durable construct that is anatomically accurate. Most femoral components with either cemented or cementless design have a fixed tapered proximal shape. The proximal femoral anatomy is changed due to previous hip surgery for fixation of an intertrochanteric hip fracture, proximal femoral osteotomy, or a fibular allograft for avascular necrosis. The modular S-ROM (DePuy Orthopaedics Inc., Warsaw, Ind) hip stem accommodates these issues and independently prepares the proximal and distal portion of the femur. In preparation and implantation, the S-ROM hip stem creates less hoop stresses on potentially fragile stress risers from screws and thin bone. The S-ROM hip stem also prepares a previously distorted anatomy by milling through cortical bone that can occlude the femoral medullar canals and recreate proper femoral anteversion and reduces the risk of intraoperative or postoperative periprosthetic fracture due to the flexible titanium-slotted stem. The S-ROM femoral stem is recommended for challenging total hip reconstructions.

  2. Well fluid isolation and sample apparatus and method

    DOEpatents

    Schalla, Ronald; Smith, Ronald M.; Hall, Stephen H.; Smart, John E.

    1995-01-01

    The present invention specifically permits purging and/or sampling of a well but only removing, at most, about 25% of the fluid volume compared to conventional methods and, at a minimum, removing none of the fluid volume from the well. The invention is an isolation assembly that is inserted into the well. The isolation assembly is designed so that only a volume of fluid between the outside diameter of the isolation assembly and the inside diameter of the well over a fluid column height from the bottom of the well to the top of the active portion (lower annulus) is removed. A seal may be positioned above the active portion thereby sealing the well and preventing any mixing or contamination of inlet fluid with fluid above the packer. Purged well fluid is stored in a riser above the packer. Ports in the wall of the isolation assembly permit purging and sampling of the lower annulus along the height of the active portion.

  3. Rationale, study design, and implementation of the ACS1 study: effect of azilsartan on circadian and sleep blood pressure as compared with amlodipine.

    PubMed

    Kario, Kazuomi; Hoshide, Satoshi

    2014-06-01

    The ACS1 (Azilsartan Circadian and Sleep Pressure - the first study) is a multicenter, randomized, open-label, two parallel-group study carried out to investigate the efficacy of an 8-week oral treatment with azilsartan 20 mg in comparison with amlodipine 5 mg. The patients with stage I or II primary hypertension will be randomly assigned to either an azilsartan group (n=350) or an amlodipine group (n=350). The primary endpoint is a change in nocturnal systolic blood pressure (BP) as measured by ambulatory BP monitoring at the end of follow-up relative to the baseline level during the run-in period. In addition, we will carry out the same analysis after dividing four different nocturnal BP dipping statuses (extreme-dippers, dippers, nondipper, and risers). The findings of this study will help in establishing an appropriate antihypertensive treatment for hypertensive patients with a disrupted circadian BP rhythm.

  4. Rationale, study design, and implementation of the ACS1 study: effect of azilsartan on circadian and sleep blood pressure as compared with amlodipine

    PubMed Central

    Hoshide, Satoshi

    2014-01-01

    Objective The ACS1 (Azilsartan Circadian and Sleep Pressure – the first study) is a multicenter, randomized, open-label, two parallel-group study carried out to investigate the efficacy of an 8-week oral treatment with azilsartan 20 mg in comparison with amlodipine 5 mg. Materials and methods The patients with stage I or II primary hypertension will be randomly assigned to either an azilsartan group (n=350) or an amlodipine group (n=350). The primary endpoint is a change in nocturnal systolic blood pressure (BP) as measured by ambulatory BP monitoring at the end of follow-up relative to the baseline level during the run-in period. In addition, we will carry out the same analysis after dividing four different nocturnal BP dipping statuses (extreme-dippers, dippers, nondipper, and risers). Conclusion The findings of this study will help in establishing an appropriate antihypertensive treatment for hypertensive patients with a disrupted circadian BP rhythm. PMID:24637789

  5. European Scientific Notes. Volume 36, Number 4.

    DTIC Science & Technology

    1982-03-30

    de of gray cast iron, Mampaey demonstrated that Recherches Scientifiques et Techniques de the minimum riser dimensions needed to obtain I’lndustrie...through the nonprofit He is now making a similar study of ’nodular Industrial association Fabrimetal (Fdlration des cast iron. entreprises de I’industrie...SCIENTIFIC NOTES April 6. PERFORMING ORG. REPORT NUMBER 7. AUTHOR(&) II. CONTRACT OR GRANT NUMBER(e) 9. PERFORMING ORGANIZATION NAME AND ADDRESS 10

  6. Using Postschool Outcome Data To Improve Practices and Policies in Restructured Inclusive High Schools. Research Institute on Secondary Education Reform (RISER) for Youth with Disabilities Brief.

    ERIC Educational Resources Information Center

    Mooney, Marianne; Phelps, L. Allen; Anctil, Tina M.

    This paper reports on an ongoing 5-year study on practices and policies that improve postschool outcomes for students with disabilities in significantly restructured high schools. Four high schools with strong internal accountability measures are subjects of an intensive longitudinal study. The schools are in both urban and smaller communities in…

  7. A Study of Cumulative Fatigue Damage in 2011-T3 Aluminum Alloy.

    DTIC Science & Technology

    1981-08-01

    isecuippd’i one horse ow’ur %-.3riable 1ce dl r , c oW s... 21 th, a cvcltc (2aunter, ana a varialhV- eccoi., crank Lind Ollv Th dnaic oain .’S tern... iud under a microscope for circu::&rential tool m-irks and stress risers. ? he specimen was then placed In the m’nachine grips by’ positioning t

  8. 3D Numerical Prediction of Gas-Solid Flow Behavior in CFB Risers for Geldart A and B Particles

    NASA Astrophysics Data System (ADS)

    Özel, A.; Fede, P.; Simonin, O.

    In this study, mono-disperse flows in squared risers conducted with A and B-type particles were simulated by Eulerian n-fluid 3D unsteady code. Two transport equations developed in the frame of kinetic theory of granular media supplemented by the interstitial fluid effect and the interaction with the turbulence (Balzer et al., 1996) are resolved to model the effect of velocity fluctuations and inter-particle collisions on the dispersed phase hydrodynamic. The studied flow geometries are three-dimensional vertical cold channels excluding cyclone, tampon and returning pipe of a typical circulating fluidized bed. For both type of particles, parametric studies were carried out to determine influences of boundary conditions, physical parameters and turbulence modeling. The grid dependency was analyzed with mesh refinement in horizontal and axial directions. For B-type particles, the results are in good qualitative agreement with the experiments and numerical predictions are slightly improved by the mesh refinement. On the contrary, the simulations with A-type particles show a less satisfactory agreement with available measurements and are highly sensitive to mesh refinement. Further studies are carried out to improve the A-type particles by modeling subgrid-scale effects in the frame of large-eddy simulation approach.

  9. Six-month observational study of prompted stair climbing.

    PubMed

    Kerr, J; Eves, F; Carroll, D

    2001-11-01

    Despite strong evidence that prompts at the point of choice between escalators and stairs encourage stair use, the long-term effects of stair prompts have not yet been investigated. Presented here are the results of a 6-month observational study of prompted stair climbing. Escalator and adjacent stair use were monitored in a shopping mall in the Midlands region of the United Kingdom. Participants were coded for gender, age, and ethnicity. A 2-week baseline period was followed by a 12-week intervention using motivating messages on the stair risers. Follow-up data were also collected for 2 weeks immediately after the removal of the banners and 6 weeks later. A total of 45,361 escalator/stair-choice observations were made. Stair use increased significantly during the intervention period and, when the banners were removed, remained higher than at baseline. There were also significant interactions with time across the different population groups. The full public health benefits of increasing physical activity levels can only be realized if the activity is sustained. These results demonstrate that stair-riser banners can elicit a sustained increase in stair use and, even when the banners were withdrawn, overall stair use remained higher than at baseline. Copyright 2001 American Health Foundation and Academic Press.

  10. New access to the deep interior of the Nankai accretionary complex and comprehensive characterization of subduction inputs and recent mega splay fault activity (IODP-NanTroSEIZE Expedition 338)

    NASA Astrophysics Data System (ADS)

    Strasser, Michael; Moore, Gregory F.; Kanagawa, Kyuichi; Dugan, Brandon; Fabbri, Olivier; Toczko, Sean; Maeda, Lena

    2013-04-01

    The Nankai Trough Seismogenic Zone Experiment (NanTroSEIZE) is a coordinated, multi-expedition Integrated Ocean Drilling Program (IODP) drilling project designed to investigate fault mechanics and seismogenesis along subduction megathrusts through direct sampling, in situ measurements, and long-term monitoring in conjunction with allied laboratory and numerical modeling studies. IODP Expedition 338 (1 October 2012 - 13 January 2013), extended riser Hole C0002F from 856 meters below the sea floor (mbsf) to 2005 mbsf. Site C0002 is the centerpiece of the NanTroSEIZE project, and is planned to be deepened to eventually reach the seismogenic fault zone during upcoming drilling expeditions. The original Exp. 338 operational plan to case the hole to 3600 mbsf had to be revised as sudden changes in sea conditions resulted in damage to parts of the riser system, thus the hole was suspended at 2005 mbsf but left for future re-entry. The revised operation plan included additional riserless logging and coring of key targets not sampled during previous NanTroSEIZE expeditions, but relevant to comprehensively characterize the alteration stage of the oceanic basement input to the subduction zone, the early stage of Kumano Basin evolution and the recent activity of the shallow mega splay fault zone system and submarine landslides. Here we present preliminary results from IODP Exp. 338: Logging While Drilling (LWD), mud gas monitoring and analysis on cuttings from the deep riser hole characterize two lithological units within the internal accretionary prism, separated by a prominent fault zone at ~1640 mbsf. Internal style of deformation, downhole increase of thermogenically formed formation gas and evidence for mechanical compaction and cementation document a complex structural evolution and provide unprecedented insights into the mechanical state and behavior of the wedge at depth. Additionally, multiple samples of the unconformity between the Kumano Basin and accretionary prism at Site C0002 shed new light on this debatable unconformity boundary and suggest variable erosional processes active on small spatial scales. Results from riserless drilling at input Site C0012 include 178.7 m of detailed LWD characterization of the oceanic basement, indicating an upper ~100 m zone of altered pillow basalts and sheet flow deposits, and a lower, presumably less altered basement unit without indication for interlayered sediment horizons. Low angle faults identified in X-ray Computed Tomography images and structural investigation on cores from Site C0022, located in the slope basin immediately seaward of the megasplay fault zone, indicate splay-fault-related, out-of-sequence thrusting within slope basin sediments and shed new light on recent activity of the megasplay. Lastly, Exp. 338 added additional coring to improve our understanding of submarine landslides in the slope basins seaward of the splay fault and yields new LWD data to characterize in situ internal structures and properties of mass-transport deposits as it relates to the dynamics and kinematics of submarine landslides.

  11. Hydrodynamic study of an internal airlift reactor for microalgae culture.

    PubMed

    Rengel, Ana; Zoughaib, Assaad; Dron, Dominique; Clodic, Denis

    2012-01-01

    Internal airlift reactors are closed systems considered today for microalgae cultivation. Several works have studied their hydrodynamics but based on important solid concentrations, not with biomass concentrations usually found in microalgae cultures. In this study, an internal airlift reactor has been built and tested in order to clarify the hydrodynamics of this system, based on microalgae typical concentrations. A model is proposed taking into account the variation of air bubble velocity according to volumetric air flow rate injected into the system. A relationship between riser and downcomer gas holdups is established, which varied slightly with solids concentrations. The repartition of solids along the reactor resulted to be homogenous for the range of concentrations and volumetric air flow rate studied here. Liquid velocities increase with volumetric air flow rate, and they vary slightly when solids are added to the system. Finally, liquid circulation time found in each section of the reactor is in concordance with those employed in microalgae culture.

  12. An approach for drag correction based on the local heterogeneity for gas-solid flows

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Tingwen; Wang, Limin; Rogers, William

    2016-09-22

    The drag models typically used for gas-solids interaction are mainly developed based on homogeneous systems of flow passing fixed particle assembly. It has been shown that the heterogeneous structures, i.e., clusters and bubbles in fluidized beds, need to be resolved to account for their effect in the numerical simulations. Since the heterogeneity is essentially captured through the local concentration gradient in the computational cells, this study proposes a simple approach to account for the non-uniformity of solids spatial distribution inside a computational cell and its effect on the interaction between gas and solid phases. Finally, to validate this approach, themore » predicted drag coefficient has been compared to the results from direct numerical simulations. In addition, the need to account for this type of heterogeneity is discussed for a periodic riser flow simulation with highly resolved numerical grids and the impact of the proposed correction for drag is demonstrated.« less

  13. LM-research opportunities and activities at Beer-Sheva

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lesin, S.

    1996-06-01

    Energy conversion concepts based on liquid metal (LM) magnetohydrodynamic (MHD) technology was intensively investigated at the Center for MHD Studies (CMHDS), in the Ben-Gurion University of the Negev in Israel. LMMHD energy conversion systems operate in a closed cycle as follows: heat intended for conversion into electricity is added to a liquid metal contained in a closed loop of pipes. The liquid metal is mixed with vapor or gas introduced from outside so that a two-phase mixture is formed. The gaseous phase performs a thermodynamic cycle, converting a certain amount of heat into mechanical energy of the liquid metal. Thismore » energy is converted into electrical power as the metal flows across a magnetic field in the MHD channel. Those systems where the expanding thermodynamic fluid performs work against gravitational forces (natural circulation loops) and using heavy liquid metals are named ETGAR systems. A number of different heavy-metal facilities have been specially constructed and tested with fluid combinations of mercury and steam, mercury and nitrogen, mercury and freon, lead-bismuth and steam, and lead and steam. Since the experimental investigation of such flows is a very difficult task and all the known measurment methods are incomplete and not fully reliable, a variety of experimental approaches have been developed. In most experiments, instantaneous pressure distribution along the height of the upcomer were measured and the average void fraction was calculated numerically using the one-dimensional equation for the two-phase flow. The research carried out at the CMHDS led to significant improvements in the characterization of the two-phase phenomena expected in the riser of ETGAR systems. One of the most important outcomes is the development of a new empirical correlation which enables the reliable prediction of the velocity ratio between the LM and the steam (slip), the friction factor, as well as of the steam void fraction distribution along the riser.« less

  14. JPRS Report, East Europe

    DTIC Science & Technology

    1988-03-07

    risers can manage to get hold of tomatoes and horseradish in the market. Cauliflower and celery are luxury vegetables. "Thank God that we are in...he also listened to reports about the workers’ uprising in Kronstadt in November, "but very quietly, because the secret police have big ears ." Bonn...shipments and delivers them reliably. Since the call for donations in Germany does not fall on deaf ears , the relief organizations are in a position to

  15. PBF Cooling Tower and it Auxiliary Building (PER624) to left ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PBF Cooling Tower and it Auxiliary Building (PER-624) to left of tower. Camera facing west and the east louvered face of the tower. Details include secondary coolant water riser piping and flow control valves (butterfly valves) to distribute water evenly to all sections of tower. Photographer: Holmes. Date: May, 20, 1970. INEEL negative no. 70-2322 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  16. Flow Studies of Decelerators at Supersonic Speeds

    NASA Technical Reports Server (NTRS)

    1959-01-01

    Wind tunnel tests recorded the effect of decelerators on flow at various supersonic speeds. Rigid parachute models were tested for the effects of porosity, shroud length, and number of shrouds. Flexible model parachutes were tested for effects of porosity and conical-shaped canopy. Ribbon dive brakes on a missile-shaped body were tested for effect of tension cable type and ribbon flare type. The final test involved a plastic sphere on riser lines.

  17. In situ rock strength and far field stress in the Nankai accretionary complex: Integration of downhole data from multiple wells

    NASA Astrophysics Data System (ADS)

    Huffman, K. A.; Saffer, D. M.

    2014-12-01

    Knowing the magnitude of tectonic stress and rock strength at seismically active margins is important towards understanding fault strength and failure mechanics, yet both are difficult to measure in situ. Recent work at subduction margins, including Integrated Ocean Drilling Program (IODP) Nankai Trough Subduction Zone Experiment (NanTroSEIZE) drillsites, uses the width of compressional wellbore breakouts (BO), which depends on far field stress conditions, rock strength, and borehole annular pressure (APRS), to estimate the magnitude of horizontal principal stresses (SHmax and Shmin); estimates are problematic due to uncertainty in rock strength (unconfined compressive strength/UCS- for which direct measurements are scarce) and rheology that govern stress distribution at the wellbore. We conduct a novel case study at IODP Site C0002, where a hole was drilled twice with different boundary conditions, providing an opportunity to define in situ stress and strength from field data. Site C0002 is the main deep riser borehole for NanTroSEIZE, located near the seaward edge of the Kumano Basin above the seismogenic plate boundary, ~30 km from the trench. Several boreholes were drilled at the site. During IODP Expedition 314 in 2007, Hole C0002A was drilled with a suite of logging while drilling (LWD) tools to 1401 mbsf in a riserless mode. Hole C0002F, ~70 m away, was drilled to 862 mbsf in riserless mode during Exp. 326 in 2010 and deepened to 2005 mbsf in a riser mode during Expedition 338 in 2012-2013. Increased APRS achieved by riser drilling stabilizes the borehole and suppresses BO, consistent with resistivity imaging data from Exp. 314 that document well-developed, continuous BO throughout the borehole, and data from Expedition 338 indicating few BO. We use a semi-Newtonian approach to solve for stress and UCS consistent with the observed BO width and measured APRS in the two holes over the interval from 862-2005 mbsf. Effective SHmax ranges from ~10-30 MPa and indicate a strike-slip or thrust regime. Our results indicate UCS is higher than predicted by empirical relations and a small suite of laboratory tests by as much as 20 MPa. This apparent discrepancy may indicate that the failure criterion, or assumed distribution of stresses around the wellbore in analyses of far field stress, may not be appropriate in this setting.

  18. Experiment for transient effects of sudden catastrophic loss of vacuum on a scaled superconducting radio frequency cryomodule

    NASA Astrophysics Data System (ADS)

    Dalesandro, Andrew A.; Theilacker, Jay; Van Sciver, Steven

    2012-06-01

    Safe operation of superconducting radio frequency (SRF) cavities require design consideration of a sudden catastrophic loss of vacuum (SCLV) adjacent with liquid helium (LHe) vessels and subsequent dangers. An experiment is discussed to test the longitudinal effects of SCLV along the beam line of a string of scaled SRF cavities. Each scaled cavity includes one segment of beam tube within a LHe vessel containing 2 K saturated LHe, and a riser pipe connecting the LHe vessel to a common gas header. At the beam tube inlet is a fast acting solenoid valve to simulate SCLV and a high/low range orifice plate flow-meter to measure air influx to the cavity. The gas header exit also has an orifice plate flow-meter to measure helium venting the system at the relief pressure of 0.4 MPa. Each cavity is instrumented with Validyne pressure transducers and Cernox thermometers. The purpose of this experiment is to quantify the time required to spoil the beam vacuum and the effects of transient heat and mass transfer on the helium system. Heat transfer data is expected to reveal a longitudinal effect due to the geometry of the experiment. Details of the experimental design criteria and objectives are presented.

  19. Computational fluid dynamics (CFD) analysis of airlift bioreactor: effect of draft tube configurations on hydrodynamics, cell suspension, and shear rate.

    PubMed

    Pawar, Sanjay B

    2018-01-01

    The biomass productivity of microalgae cells mainly depends on the hydrodynamics of airlift bioreactor (ABR). Thus, the hydrodynamics of concentric tube ABR was initially studied using two-phase three-dimensional CFD simulations with the Eulerian-Lagrangian approach. The performance of ABR (17 L) was examined for different configurations of the draft tube using various drag models such as Grace, Ishii-Zuber, and Schiller-Naumann. The gas holdups in the riser and the downcomer were well predicted using E-L approach. This work was further extended to study the dispersion of microalgae cells in the ABR using three-phase CFD simulations. In this model (combined E-E and E-L), the solid phase (microalgae cells) was dispersed into the continuous liquid phase (water), while the gas phase (air bubbles) was modeled as a particle transport fluid. The effect of non-drag forces such as virtual mass and lift forces was also considered. Flow regimes were explained on the basis of the relative gas holdup distribution in the riser and the downcomer. The microalgae cells were found in suspension for the superficial gas velocities of 0.02-0.04 m s -1 experiencing an average shear of 23.52-44.56 s -1 which is far below the critical limit of cell damage.

  20. The role of particle collisions in pneumatic transport

    NASA Technical Reports Server (NTRS)

    Mastorakos, E.; Louge, M.; Jenkins, J. T.

    1989-01-01

    A model of dilute gas-solid flow in vertical risers is developed in which the particle phase is treated as a granular material, the balance equations for rapid granular flow are modified to incorporate the drag force from the gas, and boundary conditions, based on collisional exchanges of momentum and energy at the wall, are employed. In this model, it is assumed that the particle fluctuations are determined by inter-particle collisions only and that the turbulence of the gas is unaffected by the presence of the particles. The model is developed in the context of, but not limited to, steady, fully developed flow. A numerical solution of the resulting governing equations provides concentration profiles generally observed in dilute pneumatic flow, velocity profiles in good agreement with the measurements of Tsuji, et al. (1984), and an explanation for the enhancement of turbulence that they observed.

  1. National Program for Inspection of Non-Federal Dams. Oliverian Dam (NH-00268) (NHWRB 02306), Connecticut River Basin, Benton, New Hampshire. Phase I Inspection Report.

    DTIC Science & Technology

    1979-05-01

    Condition of protective coating ; _. inside and out Corrosion ; Damaged parts_; Loose___ Other . .- Concrete : Cracking_/ I Spallingo_; Other...spillways have uncontrolled inlets. The principal - spillway consists of a drop inlet concrete riser which discharges to a 48-inch diameter reinforced... concrete conduit which passes through the dam (see Photos 3 and 5). The concrete conduit discharges to a plunge pool at the pipe outlet. (See Photos 8 and 9

  2. KSC-98pc1465

    NASA Image and Video Library

    1998-10-28

    The day before the launch of mission STS-95, the Press Site was inundated with 40 trailers, 75 trucks and RVs, 8 stages and 8 risers to accommodate the 3,750 media requests to cover the launch and return to space of John H. Glenn Jr., a senator from Ohio. Glenn flew aboard Friendship 7 in February 1962, and was the first American to orbit the Earth. Glenn is one of a crew of seven on board Space Shuttle Discovery for the nine-day mission

  3. A Survey of Corrosion and Conditions of Corrosion Protection Systems in Civil Works Structures of the U.S. Army Corps of Engineers

    DTIC Science & Technology

    2014-09-01

    corrosion: coatings and cathodic protection (CP). Coatings consist of paints, epoxies, enamels , metalizing, and other coatings. CP is a chem- ical means...environmental factors such as water quality and resistivity. One of the major problems associated with lock gates is structural cracking in the...One of the problems described by Mr. Davis is fatigue crack growth resulting from the poor welding usually associated with stress risers and

  4. Investigation of prediction methods for the loads and stresses of Apollo type spacecraft parachutes. Volume 1: Loads

    NASA Technical Reports Server (NTRS)

    Mickey, F. E.; Mcewan, A. J.; Ewing, E. G.; Huyler, W. C., Jr.; Khajeh-Nouri, B.

    1970-01-01

    An analysis was conducted with the objective of upgrading and improving the loads, stress, and performance prediction methods for Apollo spacecraft parachutes. The subjects considered were: (1) methods for a new theoretical approach to the parachute opening process, (2) new experimental-analytical techniques to improve the measurement of pressures, stresses, and strains in inflight parachutes, and (3) a numerical method for analyzing the dynamical behavior of rapidly loaded pilot chute risers.

  5. Sinker tectonics - An approach to the surface of Miranda

    NASA Technical Reports Server (NTRS)

    Janes, D. M.; Melosh, H. J.

    1988-01-01

    Two of the proposed explanations for the coronae seen on Miranda involve mantle convection driven by density anomalies. In the sinker model, the coronae result from late-accreting large silicate bodies slowly sinking through an icy mantle toward the body's center; in the riser model, they result from a compositionally produced, low-density, rising diapir. The present study determines the surface stresses induced by such density anomalies and the expected surface expressions. The results are in good agreement with the predictions of the sinker model.

  6. Road Map for Development of Crystal-Tolerant High Level Waste Glasses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matyas, Josef; Vienna, John D.; Peeler, David

    This road map guides the research and development for formulation and processing of crystal-tolerant glasses, identifying near- and long-term activities that need to be completed over the period from 2014 to 2019. The primary objective is to maximize waste loading for Hanford waste glasses without jeopardizing melter operation by crystal accumulation in the melter or melter discharge riser. The potential applicability to the Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) is also addressed in this road map.

  7. ROAD MAP FOR DEVELOPMENT OF CRYSTAL-TOLERANT HIGH LEVEL WASTE GLASSES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, K.; Peeler, D.; Herman, C.

    The U.S. Department of Energy (DOE) is building a Tank Waste Treatment and Immobilization Plant (WTP) at the Hanford Site in Washington to remediate 55 million gallons of radioactive waste that is being temporarily stored in 177 underground tanks. Efforts are being made to increase the loading of Hanford tank wastes in glass while meeting melter lifetime expectancies and process, regulatory, and product quality requirements. This road map guides the research and development for formulation and processing of crystaltolerant glasses, identifying near- and long-term activities that need to be completed over the period from 2014 to 2019. The primary objectivemore » is to maximize waste loading for Hanford waste glasses without jeopardizing melter operation by crystal accumulation in the melter or melter discharge riser. The potential applicability to the Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) will also be addressed in this road map. The planned research described in this road map is motivated by the potential for substantial economic benefits (significant reductions in glass volumes) that will be realized if the current constraints (T1% for WTP and TL for DWPF) are approached in an appropriate and technically defensible manner for defense waste and current melter designs. The basis of this alternative approach is an empirical model predicting the crystal accumulation in the WTP glass discharge riser and melter bottom as a function of glass composition, time, and temperature. When coupled with an associated operating limit (e.g., the maximum tolerable thickness of an accumulated layer of crystals), this model could then be integrated into the process control algorithms to formulate crystal-tolerant high-level waste (HLW) glasses targeting high waste loadings while still meeting process related limits and melter lifetime expectancies. The modeling effort will be an iterative process, where model form and a broader range of conditions, e.g., glass composition and temperature, will evolve as additional data on crystal accumulation are gathered. Model validation steps will be included to guide the development process and ensure the value of the effort (i.e., increased waste loading and waste throughput). A summary of the stages of the road map for developing the crystal-tolerant glass approach, their estimated durations, and deliverables is provided.« less

  8. Multiphase flow modeling and simulation of explosive volcanic eruptions

    NASA Astrophysics Data System (ADS)

    Neri, Augusto

    Recent worldwide volcanic activity, such as eruptions at Mt. St. Helens, Washington, in 1980, Mt. Pinatubo, Philippines, in 1991, as well as the ongoing eruption at Montserrat, West Indies, highlighted again the complex nature of explosive volcanic eruptions as well as the tremendous risk associated to them. In the year 2000, about 500 million people are expected to live under the shadow of an active volcano. The understanding of pyroclastic dispersion processes produced by explosive eruptions is, therefore, of primary interest, not only from the scientific point of view, but also for the huge worldwide risk associated with them. The thesis deals with an interdisciplinary research aimed at the modeling and simulation of explosive volcanic eruptions by using multiphase thermo-fluid-dynamic models. The first part of the work was dedicated to the understanding and validation of recently developed kinetic theory of two-phase flow. The hydrodynamics of fluid catalytic cracking particles in the IIT riser were simulated and compared with lab experiments. Simulation results confirm the validity of the kinetic theory approach. Transport of solids in the riser is due to dense clusters. On a time-average basis the bottom of the riser and the walls are dense, in agreement with IIT experimental data. The low frequency of oscillation (about 0.2 Hz) is also in agreement with data. The second part of the work was devoted to the development of transient two-dimensional multiphase and multicomponent flow models of pyroclastic dispersion processes. In particular, the dynamics of ground-hugging high-speed and high-temperature pyroclastic flows generated by the collapse of volcanic columns or by impulsive discrete explosions, was investigated. The model accounts for the mechanical and thermal non-equilibrium between a multicomponent gas phase and N different solid phases representative of pyroclastic particles of different sizes. Pyroclastic dispersion dynamics describes the formation of the initial vertical jet, the column collapse, and the building of the pyroclastic fountain, followed by the generation of radially spreading pyroclastic flows. The development of thermal convective instabilities in the flow lead to the formation of co-ignimbritic or phoenix clouds. Simulation results strongly highlight the importance of the multiphase flow formulation of the mixture. Large particles tend to segregate and sediment along the ground, whereas fine particles tend to form ascending buoyant plumes. Mixtures rich in fine grained particles produce larger runout of the flow and larger ascending plumes than mixtures rich in coarse particles. Simulation results appear to be qualitatively in agreement with field observations, but require to be fully validated by the simulation of well-known test cases.

  9. Media blitz of mission STS-95 fills grounds around Press Site

    NASA Technical Reports Server (NTRS)

    1998-01-01

    The day before the launch of mission STS-95, the Press Site was inundated with 40 trailers, 75 trucks and RVs, 8 stages and 8 risers to accommodate the 3,750 media requests to cover the launch and return to space of John H. Glenn Jr., a senator from Ohio. Glenn flew aboard Friendship 7 in February 1962, and was the first American to orbit the Earth. Glenn is one of a crew of seven on board Space Shuttle Discovery for the nine-day mission.

  10. National Dam Safety Program. Grindstone-Lost-Muddy Creek Dam F-20 (MO 11220), Grand - Chariton Basin, Daviess County, Missouri. Phase I Inspection Report.

    DTIC Science & Technology

    1980-06-01

    for a small dam having a high hazard potential. Considering the small volume of water im- pounded and the downstream channel from the dam, one-half of...flood at damsite - Mr. Wesley Lee reported that the highest water he had seen was approximately 4 inches over the riser. (3) The principal spillway...operation. It was reported by Mr. Wesley Lee that the emergency spillway has never operated. 2.4 EVALUATION a. Availabilit X . The data in Appendix C

  11. BRIC in the Backyard: Brazil’s Economic Rise and What it Means for the United States (CSL Issue Paper, Volume 14-11, July 2011)

    DTIC Science & Technology

    2011-07-01

    component in the administration’s plans to generate future growth for the country . To develop and optimize export opportunities, the government is...seeking expanded trade ties with developing countries , as well as a strengthening of the Common Market of the South – Mercosul (Mercosur in Spanish...one of these of these geo-political risers and it is perhaps the most underestimated of the so-called BRIC countries . The term BRIC was coined by Jim

  12. Results from a scaled reactor cavity cooling system with water at steady state

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lisowski, D. D.; Albiston, S. M.; Tokuhiro, A.

    We present a summary of steady-state experiments performed with a scaled, water-cooled Reactor Cavity Cooling System (RCCS) at the Univ. of Wisconsin - Madison. The RCCS concept is used for passive decay heat removal in the Next Generation Nuclear Plant (NGNP) design and was based on open literature of the GA-MHTGR, HTR-10 and AVR reactor. The RCCS is a 1/4 scale model of the full scale prototype system, with a 7.6 m structure housing, a 5 m tall test section, and 1,200 liter water storage tank. Radiant heaters impose a heat flux onto a three riser tube test section, representingmore » a 5 deg. radial sector of the actual 360 deg. RCCS design. The maximum heat flux and power levels are 25 kW/m{sup 2} and 42.5 kW, and can be configured for variable, axial, or radial power profiles to simulate prototypic conditions. Experimental results yielded measurements of local surface temperatures, internal water temperatures, volumetric flow rates, and pressure drop along the test section and into the water storage tank. The majority of the tests achieved a steady state condition while remaining single-phase. A selected number of experiments were allowed to reach saturation and subsequently two-phase flow. RELAP5 simulations with the experimental data have been refined during test facility development and separate effects validation of the experimental facility. This test series represents the completion of our steady-state testing, with future experiments investigating normal and off-normal accident scenarios with two-phase flow effects. The ultimate goal of the project is to combine experimental data from UW - Madison, UI, ANL, and Texas A and M, with system model simulations to ascertain the feasibility of the RCCS as a successful long-term heat removal system during accident scenarios for the NGNP. (authors)« less

  13. Predicting the Agglomeration of Cohesive Particles in a Gas-Solid Flow and its Effect on the Solids Flow

    NASA Astrophysics Data System (ADS)

    Kellogg, Kevin; Liu, Peiyuan; Lamarche, Casey; Hrenya, Christine

    2017-11-01

    In flows of cohesive particles, agglomerates will readily form and break. These agglomerates are expected to complicate how particles interact with the surrounding fluid in multiphase flows, and consequently how the solids flow. In this work, a dilute flow of particles driven by gas against gravity is studied. A continuum framework, composed of a population balance to predict the formation of agglomerates, and kinetic-theory-based balances, is used to predict the flow of particles. The closures utilized for the birth and death rates due to aggregation and breakage in the population balance take into account how the impact velocity (the granular temperature) affects the outcome of a collision as aggregation, rebound, or breakage. The agglomerate size distribution and solids velocity predicted by the continuum framework are compared to discrete element method (DEM) simulations, as well to experimental results of particles being entrained from the riser of a fluidized bed. Dow Corning Corporation.

  14. A Framework for Performing Multiscale Stochastic Progressive Failure Analysis of Composite Structures

    NASA Technical Reports Server (NTRS)

    Bednarcyk, Brett A.; Arnold, Steven M.

    2006-01-01

    A framework is presented that enables coupled multiscale analysis of composite structures. The recently developed, free, Finite Element Analysis - Micromechanics Analysis Code (FEAMAC) software couples the Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC) with ABAQUS to perform micromechanics based FEA such that the nonlinear composite material response at each integration point is modeled at each increment by MAC/GMC. As a result, the stochastic nature of fiber breakage in composites can be simulated through incorporation of an appropriate damage and failure model that operates within MAC/GMC on the level of the fiber. Results are presented for the progressive failure analysis of a titanium matrix composite tensile specimen that illustrate the power and utility of the framework and address the techniques needed to model the statistical nature of the problem properly. In particular, it is shown that incorporating fiber strength randomness on multiple scales improves the quality of the simulation by enabling failure at locations other than those associated with structural level stress risers.

  15. A Framework for Performing Multiscale Stochastic Progressive Failure Analysis of Composite Structures

    NASA Technical Reports Server (NTRS)

    Bednarcyk, Brett A.; Arnold, Steven M.

    2007-01-01

    A framework is presented that enables coupled multiscale analysis of composite structures. The recently developed, free, Finite Element Analysis-Micromechanics Analysis Code (FEAMAC) software couples the Micromechanics Analysis Code with Generalized Method of Cells (MAC/GMC) with ABAQUS to perform micromechanics based FEA such that the nonlinear composite material response at each integration point is modeled at each increment by MAC/GMC. As a result, the stochastic nature of fiber breakage in composites can be simulated through incorporation of an appropriate damage and failure model that operates within MAC/GMC on the level of the fiber. Results are presented for the progressive failure analysis of a titanium matrix composite tensile specimen that illustrate the power and utility of the framework and address the techniques needed to model the statistical nature of the problem properly. In particular, it is shown that incorporating fiber strength randomness on multiple scales improves the quality of the simulation by enabling failure at locations other than those associated with structural level stress risers.

  16. Sleep schedules and school performance in Indigenous Australian children.

    PubMed

    Blunden, Sarah; Magee, Chris; Attard, Kelly; Clarkson, Larissa; Caputi, Peter; Skinner, Timothy

    2018-04-01

    Sleep duration and sleep schedule variability have been related to negative health and well-being outcomes in children, but little is known about Australian Indigenous children. Data for children aged 7-9 years came from the Australian Longitudinal Study of Indigenous Children and the National Assessment Program-Literacy and Numeracy (NAPLAN). Latent class analysis determined sleep classes taking into account sleep duration, bedtimes, waketimes, and variability in bedtimes from weekdays to weekends. Regression models tested whether the sleep classes were cross-sectionally associated with grade 3 NAPLAN scores. Latent change score modeling then examined whether the sleep classes predicted changes in NAPLAN performance from grades 3 to 5. Five sleep schedule classes were identified: normative sleep, early risers, long sleep, variable sleep, and short sleep. Overall, long sleepers performed best, with those with reduced sleep (short sleepers and early risers) performing the worse on grammar, numeracy, and writing performance. Latent change score results also showed that long sleepers performed best in spelling and writing and short sleepers and typical sleepers performed the worst over time. In this sample of Australian Indigenous children, short sleep was associated with poorer school performance compared with long sleep, with this performance worsening over time for some performance indicators. Other sleep schedules (eg, early wake times and variable sleep) also had some relationships with school performance. As sleep scheduling is modifiable, this offers opportunity for improvement in sleep and thus performance outcomes for these and potentially all children. Copyright © 2018 National Sleep Foundation. Published by Elsevier Inc. All rights reserved.

  17. Hydrologic and water-quality data in selected agricultural drainages in Beaufort and Hyde Counties, North Carolina, 1990-92

    USGS Publications Warehouse

    Treece, M.W.

    1993-01-01

    An investigation was begun in 1988 to: (1) quantify nutrient, sediment, and freshwater loadings in canals that collect drainage from cropland field ditches; (2) determine the effects of tide gates and flashboard risers on these loadings and on receiving water quality; and (3) characterize the effects of drainage on the salinity regime of a tidal creek. Data were collected in three canals in Hyde County, two canals in Beaufort County, and in Campbell Creek, which receives drainage directly from the Beaufort County canals. A tide gate was placed in one of the Hyde County canals near the beginning of the investigation. In August 1990 following more than 2 years of data collection, control structures were placed in the remaining two Hyde County canals. Flashboard risers were installed in the Beaufort County canals in April 1991. Hydrologic and water quality data are presented for each of the study sites for the period of October 1990 through May 1992. Following a description of the study sites and data collection methods, data are presented for the five drainage canals and Campbell Creek. The data collected included: (1) daily values of accumulated precipitation; (2) water level statistics; (3) daily mean values of discharge in the canals; (4) biweekly water quality measurements and sample analyses; (5) storm-event water quality measurements and sample analyses; (6) continuous records of specific conductance in the canals; (7) vertical profiles of salinity in Campbell Creek; and (8) daily mean values of salinity at five sites at Campbell Creek.

  18. Carbon attrition during the circulating fluidized bed combustion of a packaging-derived fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mastellone, M.L.; Arena, U.

    1999-05-01

    Cylindrical pellets of a market-available packaging-derived fuel, obtained from a mono-material collection of polyethylene terephthalate (PET) bottles, were batchwise fed to a laboratory scale circulating fluidized bed (CFB) combustor. The apparatus, whose riser was 41 mm ID and 4 m high, was operated under both inert and oxidizing conditions to establish the relative importance of purely mechanical attrition and combustion-assisted attrition in generating carbon fines. Silica sand particles of two size distributions were used as inert materials. For each run, carbon load and carbon particle size distribution in the riser and rates of attrited carbon fines escaping the combustor weremore » determined as a function of time. A parallel investigation was carried out with a bubbling fluidized bed (BFB) combustor to point out peculiarities of attrition in CFB combustors. After devolatilization, PET pellets generated fragile aggregates of char and sand, which easily crumbled, leading to single particles, partially covered by a carbon-rich layer. The injected fixed carbon was therefore present in the bed in three phases: an A-phase, made of aggregates of sand and char, an S-phase, made of individual carbon-covered sand particles and an F-phase, made of carbon fines, abraded by the surfaces of the A- and S-phases. The effects of the size of inert material on the different forms under which fixed carbon was present in the bed and on the rate of escape of attrited carbon fines from the combustor were investigated. Features of carbon attrition in CFB and BFB combustors are discussed.« less

  19. A new one-man submarine is tested as vehicle for solid rocket booster retrieval

    NASA Technical Reports Server (NTRS)

    2000-01-01

    A Diver Operator Plug (DOP) is being pulled down into the ocean by a newly designed one-man submarine known as DeepWorker 2000. The activity is part of an operation to attach the plug to a mockup of a solid rocket booster nozzle. DeepWorker 2000 is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach the DOP to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program.

  20. Application of a Smart Parachute Release Algorithm to the CPAS Test Architecture

    NASA Technical Reports Server (NTRS)

    Bledsoe, Kristin

    2013-01-01

    One of the primary test vehicles for the Capsule Parachute Assembly System (CPAS) is the Parachute Test Vehicle (PTV), a capsule shaped structure similar to the Orion design but truncated to fit in the cargo area of a C-17 aircraft. The PTV has a full Orion-like parachute compartment and similar aerodynamics; however, because of the single point attachment of the CPAS parachutes and the lack of Orion-like Reaction Control System (RCS), the PTV has the potential to reach significant body rates. High body rates at the time of the Drogue release may cause the PTV to flip while the parachutes deploy, which may result in the severing of the Pilot or Main risers. In order to prevent high rates at the time of Drogue release, a "smart release" algorithm was implemented in the PTV avionics system. This algorithm, which was developed for the Orion Flight system, triggers the Drogue parachute release when the body rates are near a minimum. This paper discusses the development and testing of the smart release algorithm; its implementation in the PTV avionics and the pretest simulation; and the results of its use on two CPAS tests.

  1. KSC-00padig012

    NASA Image and Video Library

    2000-04-22

    KENNEDY SPACE CENTER, FLA. -- A Diver Operator Plug (DOP) is being pulled down into the ocean by a newly designed one-man submarine known as DeepWorker 2000. The activity is part of an operation to attach the plug to a mockup of a solid rocket booster nozzle. DeepWorker 2000 is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach the DOP to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program

  2. KSC00padig012

    NASA Image and Video Library

    2000-04-22

    KENNEDY SPACE CENTER, FLA. -- A Diver Operator Plug (DOP) is being pulled down into the ocean by a newly designed one-man submarine known as DeepWorker 2000. The activity is part of an operation to attach the plug to a mockup of a solid rocket booster nozzle. DeepWorker 2000 is being tested on its ability to duplicate the sometimes hazardous job United Space Alliance (USA) divers perform to recover the expended boosters in the ocean after a launch. The boosters splash down in an impact area about 140 miles east of Jacksonville and after recovery are towed back to KSC for refurbishment by the specially rigged recovery ships. DeepWorker 2000 will be used in a demonstration during retrieval operations after the upcoming STS-101 launch. The submarine pilot will demonstrate capabilities to cut tangled parachute riser lines using a manipulator arm and attach the DOP to extract water and provide flotation for the booster. DeepWorker 2000 was built by Nuytco Research Ltd., North Vancouver, British Columbia. It is 8.25 feet long, 5.75 feet high, and weighs 3,800 pounds. USA is a prime contractor to NASA for the Space Shuttle program

  3. A change in landscape: Lessons learned from abandonment of ancient Wari agricultural terraces in Southern Peru.

    PubMed

    Londoño, Ana C; Williams, Patrick Ryan; Hart, Megan L

    2017-11-01

    Ancient agricultural terrace practices have survived for millennia, sustaining populations through extreme climatic shifts and political regime changes. In arid regions with abrupt relief such as Southern Peru, agricultural terracing is undergoing a resurgence, as has seen revitalization of once abandoned terrace and hydraulic systems. Wari terraces at Cerro Baul provide clues to past cultural practices. They also document sustainable farming practices by using resilient land management techniques which can help combat desertification and degradation of arable lands. Three abandoned Wari terrace systems were mapped using microtopographic methods, the erosion patterns examined, the states of preservation compared, and then the design contrasted with modern terracing practices in the Moquegua Valley. In order to negate the harmful effects of desertification, rehabilitation and reconstruction of these terraces using ancient knowledge and techniques may be necessary. Rehabilitation must be conducted with consideration for preservation of cultural patrimony that may be encountered within the terrace treads or riser structures. With future climatic shifts impacting vulnerable dryland areas more than others, the ability to resiliently respond to these changes may be found in the lessons learned from ancient farming techniques such as the Wari. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. IODP Expedition 338: Riser and Riserless Drilling Along the NanTroSEIZE Transect

    NASA Astrophysics Data System (ADS)

    Strasser, M.; Moore, G. F.; Dugan, B.; Kanagawa, K.; Toczko, S.

    2013-12-01

    Integrated Ocean Drilling Program (IODP) Expedition 338 provided new constraints on the Kumano Basin sediments, the accretionary prism inner wedge, the seaward extension of the megasplay fault, the architecture and mechanics of landslides, and the alteration of oceanic basement of the incoming Philippine Sea plate. This was accomplished through riser and riserless drilling, logging while drilling (LWD), and cuttings and core analysis. Cuttings and LWD analyses at Hole C0002F reveal two lithologic units in the prism inner wedge which are separated by a prominent fault zone at ~1640 mbsf. Mud-gases from the inner prism show high concentrations at the top of the wedge that decrease, but become more thermogenic, with depth. These data are from the previously unaccessed deeper part of the Nankai accretionary prism. Riserless coring at Site C0002 provided data across the gas hydrate zone of the Kumano Basin, across the Kumano Basin-accretionary prism unconformity, and in the uppermost accretionary prism. Within the Kumano basin section, gas and porewater geochemistry documents microbial methane gas in hydrates that are disseminated in sandy layers. Multiple penetrations of the Kumano Basin-accretionary prism boundary and 3D seismic data show that the boundary is erosive and complex. LWD (Site C0018) and coring and LWD (Site C0021) augment existing data to better understand submarine landslide dynamics and mass-transport deposit (MTD) emplacement processes. Previous coring at Site C0018 identified six MTDs, but only two MTD intervals were detected in resistivity images that show high angle, randomly oriented bedding. Site C0021, located more proximal to the MTD source, provides constraint on MTD variability. Correlation across the sites reveals a thick MTD with an erosional base characterized by a shear zone in muddy sediments vs. a translational basal surface within coarse volcaniclastic sand in the proximal and distal/lateral areas, respectively. LWD data and cores from Site C0022 characterize the uppermost 400 m of sediment near the tip of the megasplay fault zone where it approaches the seafloor. This fault zone is inferred to be located at the interval of 80-145 mbsf, based on biostratigraphic reversals, bedding dips >20°, porosity anomalies and a change in trend of interstitial water chemistry data. LWD at Site C0012 primarily yielded insights into the nature of the incoming oceanic crust. Two crustal units were identified based on LWD data. The upper unit had gamma ray variations that may indicate changes in the crustal alteration or sediment-basalt interlayering. The deeper unit has little variation in log properties, suggesting the presence of uniform or fresh basalt. Together these data provide new constraints on the overall architecture and mechanics of the Nankai subduction zone.

  5. Microstructure and Corrosion Behavior of Laser Synthesized Cobalt Based Powder on Ti-6Al-4V

    NASA Astrophysics Data System (ADS)

    Adesina, O. S.; Popoola, A. P. I.; Pityana, S. L.; Oloruntoba, D. T.

    2018-05-01

    The corrosion behavior of titanium alloys when used for various dynamic offshore components has been a major concern of titanium drilling risers in deepwater energy extraction. A way of achieving specified requirement is the development of coatings suitable to protect the base material against corrosion. In this work, laser cladding technique which is known as a leading edge due to its distinctive properties and outcomes was used in synthesizing Co-based powder on titanium alloy. The processing parameters used were laser power of 900W; scan speed of 0.6 to 1.2 m/min; powderfeedrate1.0g/min;beamspotsize3mm;gasflowrate1.2L/min.The effects of cobalt addition and laser parameters on corrosion behavior of laser clad Ti6AL4V coating in 0.5M sulfuric medium were investigated using linear potentiodynamic polarization. The changes in microstructure and corrosion behavior were analyzed using scanning electron microscopy (SEM) while the X –ray diffraction (XRD) indicates the intermetallics in the coatings. Results showed that the coatings displayed good metallurgical bonding with dendritic formations between the coatings and the substrate. The anodic current density increased with lower scan speed. However, the corrosion current densities of laser-clad samples were lower than Ti6Al4V alloy.

  6. LiDAR-Assisted identification of an active fault near Truckee, California

    USGS Publications Warehouse

    Hunter, L.E.; Howle, J.F.; Rose, R.S.; Bawden, G.W.

    2011-01-01

    We use high-resolution (1.5-2.4 points/m2) bare-earth airborne Light Detection and Ranging (LiDAR) imagery to identify, map, constrain, and visualize fault-related geomorphology in densely vegetated terrain surrounding Martis Creek Dam near Truckee, California. Bare-earth LiDAR imagery reveals a previously unrecognized and apparently youthful right-lateral strike-slip fault that exhibits laterally continuous tectonic geomorphic features over a 35-km-long zone. If these interpretations are correct, the fault, herein named the Polaris fault, may represent a significant seismic hazard to the greater Truckee-Lake Tahoe and Reno-Carson City regions. Three-dimensional modeling of an offset late Quaternary terrace riser indicates a minimum tectonic slip rate of 0.4 ?? 0.1 mm/yr.Mapped fault patterns are fairly typical of regional patterns elsewhere in the northern Walker Lane and are in strong coherence with moderate magnitude historical seismicity of the immediate area, as well as the current regional stress regime. Based on a range of surface-rupture lengths and depths to the base of the seismogenic zone, we estimate a maximum earthquake magnitude (M) for the Polaris fault to be between 6.4 and 6.9.

  7. Numerical study of rice husk and coal co-combustion characteristics in a circulating fluidized bed

    NASA Astrophysics Data System (ADS)

    Wang, Zuomin; Li, Jiuru

    2018-02-01

    This paper discussed the rationality of coal and rice husk co-combustion. Using ICEM software, a two-dimensional model of the riser has been established for circulating fluidized bed experimental table. Using Fluent software, numerical simulation has been made for the combustion reaction of different proportions of rice husk mixed with coal. The results show that, with the increase of rice husk ratio, both the combustion temperature and the amount of nitrogen oxides decrease and the effect is gradually reduced. In this simulation, the rice husks occupying about 30% is a reasonable proportion.

  8. Investigation of Stress-Strain History Modeling at Stress Risers

    DTIC Science & Technology

    1977-06-01

    GJ6(A ’/2 = 0.0149) 21 7 Hysteresis Loops for Test GJ9(A f/2 = 0.0211) 22 8 Hysteresis Loops for Test GJI (6 ir/2 = 0.0294) 23 9 Cyclic and Monotonic...61 Hysteresis Loops for Test GJ9(A c/2=0.021 1) 105 62 Hysteresis Loops for Test GJI (At/2=0.0294) 106 63 Cyclic Locus Curve 107 64 Stable Hysteresis...tests GJI through GJ37 show that 7075-T651 aluminum both hardens and softens. The response ]or four of these tests is plotted in Figures 59 through 62

  9. Crystal accumulation in the Hanford Waste Treatment Plant high level waste melter: Summary of 2017 experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, K.; Fowley, M.

    A full-scale, transparent mock-up of the Hanford Tank Waste Treatment and Immobilization Project High Level Waste glass melter riser and pour spout has been constructed to allow for testing with visual feedback of particle settling, accumulation, and resuspension when operating with a controlled fraction of crystals in the glass melt. Room temperature operation with silicone oil and magnetite particles simulating molten glass and spinel crystals, respectively, allows for direct observation of flow patterns and settling patterns. The fluid and particle mixture is recycled within the system for each test.

  10. Apparatus for passive removal of subsurface contaminants

    DOEpatents

    Pemberton, Bradley E.; May, Christopher P.; Rossabi, Joseph

    1997-01-01

    An apparatus is provided which passively removes contaminated gases from a subsurface. The apparatus includes a riser pipe extending into a subsurface which has an exterior end in fluid communication with a valve. When well pressure is greater than atmospheric pressure, the valve opens to release contaminants into the atmosphere, and when well pressure is less than atmospheric pressure, the valve closes to prevent flow of air into the well. The valve assembly of the invention comprises a lightweight ball which is lifted from its valve seat with a slight pressure drop between the well and the atmosphere.

  11. Stress analysis of ribbon parachutes

    NASA Technical Reports Server (NTRS)

    Reynolds, D. T.; Mullins, W. M.

    1975-01-01

    An analytical method has been developed for determining the internal load distribution for ribbon parachutes subjected to known riser and aerodynamic forces. Finite elements with non-linear elastic properties represent the parachute structure. This method is an extension of the analysis previously developed by the authors and implemented in the digital computer program CANO. The present analysis accounts for the effect of vertical ribbons in the solution for canopy shape and stress distribution. Parametric results are presented which relate the canopy stress distribution to such factors as vertical ribbon strength, number of gores, and gore shape in a ribbon parachute.

  12. Apparatus for passive removal of subsurface contaminants

    DOEpatents

    Pemberton, B.E.; May, C.P.; Rossabi, J.

    1997-06-24

    An apparatus is provided which passively removes contaminated gases from a subsurface. The apparatus includes a riser pipe extending into a subsurface which has an exterior end in fluid communication with a valve. When well pressure is greater than atmospheric pressure, the valve opens to release contaminants into the atmosphere, and when well pressure is less than atmospheric pressure, the valve closes to prevent flow of air into the well. The valve assembly of the invention comprises a lightweight ball which is lifted from its valve seat with a slight pressure drop between the well and the atmosphere. 7 figs.

  13. National Dam Safety Program. Little Creek Reservoir Dam (Inventory Number VA 09506), James River Basin, James City County, Commonwealth of Virginia. Phase I Inspection Report.

    DTIC Science & Technology

    1981-02-01

    losses for the PMF were estimated at an initial loss of 1.0 inch and a constant loss rate of 0.05 inches per hour thereafter. 5.5 Reservoir Regulation ...Pertinent dam and reservoir data are shown in Table 1.1, paragraph 1.3.3. Regulation of flow from the reservoir is primarily an automatic function...Normal flows are maintained by the crest of the spillway riser at elevation 60.0 feet M.S.L. Some flow regulation can be exercised by the operation of

  14. THE HYDROTHERMAL REACTIONS OF MONOSODIUM TITANATE, CRYSTALLINE SILICOTITANATE AND SLUDGE IN THE MODULAR SALT PROCESS: A LITERATURE SURVEY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fondeur, F.; Pennebaker, F.; Fink, S.

    2010-11-11

    The use of crystalline silicotitanate (CST) is proposed for an at-tank process to treat High Level Waste at the Savannah River Site. The proposed configuration includes deployment of ion exchange columns suspended in the risers of existing tanks to process salt waste without building a new facility. The CST is available in an engineered form, designated as IE-911-CW, from UOP. Prior data indicates CST has a proclivity to agglomerate from deposits of silica rich compounds present in the alkaline waste solutions. This report documents the prior literature and provides guidance for the design and operations that include CST to mitigatemore » that risk. The proposed operation will also add monosodium titanate (MST) to the supernate of the tank prior to the ion exchange operation to remove strontium and select alpha-emitting actinides. The cesium loaded CST is ground and then passed forward to the sludge washing tank as feed to the Defense Waste Processing Facility (DWPF). Similarly, the MST will be transferred to the sludge washing tank. Sludge processing includes the potential to leach aluminum from the solids at elevated temperature (e.g., 65 C) using concentrated (3M) sodium hydroxide solutions. Prior literature indicates that both CST and MST will agglomerate and form higher yield stress slurries with exposure to elevated temperatures. This report assessed that data and provides guidance on minimizing the impact of CST and MST on sludge transfer and aluminum leaching sludge.« less

  15. Methodology for extracting local constants from petroleum cracking flows

    DOEpatents

    Chang, Shen-Lin; Lottes, Steven A.; Zhou, Chenn Q.

    2000-01-01

    A methodology provides for the extraction of local chemical kinetic model constants for use in a reacting flow computational fluid dynamics (CFD) computer code with chemical kinetic computations to optimize the operating conditions or design of the system, including retrofit design improvements to existing systems. The coupled CFD and kinetic computer code are used in combination with data obtained from a matrix of experimental tests to extract the kinetic constants. Local fluid dynamic effects are implicitly included in the extracted local kinetic constants for each particular application system to which the methodology is applied. The extracted local kinetic model constants work well over a fairly broad range of operating conditions for specific and complex reaction sets in specific and complex reactor systems. While disclosed in terms of use in a Fluid Catalytic Cracking (FCC) riser, the inventive methodology has application in virtually any reaction set to extract constants for any particular application and reaction set formulation. The methodology includes the step of: (1) selecting the test data sets for various conditions; (2) establishing the general trend of the parametric effect on the measured product yields; (3) calculating product yields for the selected test conditions using coupled computational fluid dynamics and chemical kinetics; (4) adjusting the local kinetic constants to match calculated product yields with experimental data; and (5) validating the determined set of local kinetic constants by comparing the calculated results with experimental data from additional test runs at different operating conditions.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pallesen, T.R.; Braestrup, M.W.; Jorgensen, O.

    Development of Danish North Sea hydrocarbon resources includes the 17-km Rolf pipeline installed in 1985. This one consists of an insulated 8-in. two-phase flow product line with a 3-in. piggyback gas lift line. A practical solution to design of this insulated pipeline, including the small diameter, piggyback injection line was corrosion coating of fusion bonded epoxy (FBE) and polyethylene (PE) sleeve pipe. The insulation design prevents hydrate formation under the most conservative flow regime during gas lift production. Also, the required minimum flow rate during the initial natural lift period is well below the value anticipiated at the initiation ofmore » gas lift. The weight coating design ensures stability on the seabed during the summer months only; thus trenching was required during the same installation season. Installation of insulated flowlines serving marginal fields is a significant feature of North Sea hydrocarbon development projects. The Skjold field is connected to Gorm by a 6-in., two-phase-flow line. The 11-km line was installed in 1982 as the first insulated pipeline in the North Sea. The Rolf field, located 17 km west of Gorm, went on stream Jan. 2. The development includes an unmanned wellhead platform and an insulated, two-phase-flow pipeline to the Gorm E riser platform. After separation on the Gorm C process platform, the oil and condensate are transported to shore through the 20-in. oil pipeline, and the natural gas is piped to Tyra for transmission through the 30-in. gas pipeline. Oil production at Rolf is assisted by the injection of lift gas, transported from Gorm through a 3-in. pipeline, installed piggyback on the insulated 8-in. product line. The seabed is smooth and sandy, the water depth varying between 33.7 m (110.5 ft) at Rolf and 39.1 m (128 ft) at Gorm.« less

  17. Impact of Common Diabetes Risk Variant in MTNR1B on Sleep, Circadian, and Melatonin Physiology.

    PubMed

    Lane, Jacqueline M; Chang, Anne-Marie; Bjonnes, Andrew C; Aeschbach, Daniel; Anderson, Clare; Cade, Brian E; Cain, Sean W; Czeisler, Charles A; Gharib, Sina A; Gooley, Joshua J; Gottlieb, Daniel J; Grant, Struan F A; Klerman, Elizabeth B; Lauderdale, Diane S; Lockley, Steven W; Munch, Miriam; Patel, Sanjay; Punjabi, Naresh M; Rajaratnam, Shanthakumar M W; Rueger, Melanie; St Hilaire, Melissa A; Santhi, Nayantara; Scheuermaier, Karin; Van Reen, Eliza; Zee, Phyllis C; Shea, Steven A; Duffy, Jeanne F; Buxton, Orfeu M; Redline, Susan; Scheer, Frank A J L; Saxena, Richa

    2016-06-01

    The risk of type 2 diabetes (T2D) is increased by abnormalities in sleep quantity and quality, circadian alignment, and melatonin regulation. A common genetic variant in a receptor for the circadian-regulated hormone melatonin (MTNR1B) is associated with increased fasting blood glucose and risk of T2D, but whether sleep or circadian disruption mediates this risk is unknown. We aimed to test if MTNR1B diabetes risk variant rs10830963 associates with measures of sleep or circadian physiology in intensive in-laboratory protocols (n = 58-96) or cross-sectional studies with sleep quantity and quality and timing measures from self-report (n = 4,307-10,332), actigraphy (n = 1,513), or polysomnography (n = 3,021). In the in-laboratory studies, we found a significant association with a substantially longer duration of elevated melatonin levels (41 min) and delayed circadian phase of dim-light melatonin offset (1.37 h), partially mediated through delayed offset of melatonin synthesis. Furthermore, increased T2D risk in MTNR1B risk allele carriers was more pronounced in early risers versus late risers as determined by 7 days of actigraphy. Our results provide the surprising insight that the MTNR1B risk allele influences dynamics of melatonin secretion, generating a novel hypothesis that the MTNR1B risk allele may extend the duration of endogenous melatonin production later into the morning and that early waking may magnify the diabetes risk conferred by the risk allele. © 2016 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

  18. Absence of modulatory action on haptic height perception with musical pitch

    PubMed Central

    Geronazzo, Michele; Avanzini, Federico; Grassi, Massimo

    2015-01-01

    Although acoustic frequency is not a spatial property of physical objects, in common language, pitch, i.e., the psychological correlated of frequency, is often labeled spatially (i.e., “high in pitch” or “low in pitch”). Pitch-height is known to modulate (and interact with) the response of participants when they are asked to judge spatial properties of non-auditory stimuli (e.g., visual) in a variety of behavioral tasks. In the current study we investigated whether the modulatory action of pitch-height extended to the haptic estimation of height of a virtual step. We implemented a HW/SW setup which is able to render virtual 3D objects (stair-steps) haptically through a PHANTOM device, and to provide real-time continuous auditory feedback depending on the user interaction with the object. The haptic exploration was associated with a sinusoidal tone whose pitch varied as a function of the interaction point's height within (i) a narrower and (ii) a wider pitch range, or (iii) a random pitch variation acting as a control audio condition. Explorations were also performed with no sound (haptic only). Participants were instructed to explore the virtual step freely, and to communicate height estimation by opening their thumb and index finger to mimic the step riser height, or verbally by reporting the height in centimeters of the step riser. We analyzed the role of musical expertise by dividing participants into non-musicians and musicians. Results showed no effects of musical pitch on high-realistic haptic feedback. Overall there is no difference between the two groups in the proposed multimodal conditions. Additionally, we observed a different haptic response distribution between musicians and non-musicians when estimations of the auditory conditions are matched with estimations in the no sound condition. PMID:26441745

  19. Catalytic Upgrading of Biomass Pyrolysis Oxygenates with Vacuum Gas Oil Using a Davison Circulating Riser Reactor

    DOE PAGES

    Jarvis, Mark W.; Olstad, Jessica; Parent, Yves; ...

    2018-01-02

    We investigate and quantitate the changes in hydrocarbon product composition while evaluating the performance and operability of the National Renewable Energy Laboratory's Davison Circulating Riser (DCR) reactor system when biomass model compounds are cofed with traditional fluid catalyst cracking (FCC) feeds and catalyst: vacuum gas oil (VGO) and equilibrium zeolite catalyst (E-Cat). Three compounds (acetic acid, guaiacol, and sorbitan monooleate) were selected to represent the major classes of oxygenates present in biomass pyrolysis vapors. These vapors can contain 30-50% oxygen as oxygenates, which create conversion complications (increased reactivity and coking) when integrating biomass vapors and liquids into fuel and chemicalmore » processes long dominated by petroleum feedstocks. We used these model compounds to determine the appropriate conditions for coprocessing with petroleum and ultimately pure pyrolysis vapors only as compared with standard baseline conditions obtained with VGO and E-Cat only in the DCR. Model compound addition decreased the DCR catalyst circulation rate, which controls reactor temperature and measures reaction heat demand, while increasing catalyst coking rates. Liquid product analyses included 2-dimensional gas chromatography time-of-flight mass spectroscopy (2D GCxGC TOFS), simulated distillation (SIM DIST), 13C NMR, and carbonyl content. Aggregated results indicated that the model compounds were converted during reaction, and despite functional group differences, product distributions for each model compound were very similar. In addition, we determined that adding model compounds to the VGO feed did not significantly affect the DCR's operability or performance. Future work will assess catalytic upgrading of biomass pyrolysis vapor to fungible hydrocarbon products using upgrading catalysts currently being developed at NREL and at Johnson Matthey.« less

  20. Catalytic Upgrading of Biomass Pyrolysis Oxygenates with Vacuum Gas Oil Using a Davison Circulating Riser Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jarvis, Mark W.; Olstad, Jessica; Parent, Yves

    We investigate and quantitate the changes in hydrocarbon product composition while evaluating the performance and operability of the National Renewable Energy Laboratory's Davison Circulating Riser (DCR) reactor system when biomass model compounds are cofed with traditional fluid catalyst cracking (FCC) feeds and catalyst: vacuum gas oil (VGO) and equilibrium zeolite catalyst (E-Cat). Three compounds (acetic acid, guaiacol, and sorbitan monooleate) were selected to represent the major classes of oxygenates present in biomass pyrolysis vapors. These vapors can contain 30-50% oxygen as oxygenates, which create conversion complications (increased reactivity and coking) when integrating biomass vapors and liquids into fuel and chemicalmore » processes long dominated by petroleum feedstocks. We used these model compounds to determine the appropriate conditions for coprocessing with petroleum and ultimately pure pyrolysis vapors only as compared with standard baseline conditions obtained with VGO and E-Cat only in the DCR. Model compound addition decreased the DCR catalyst circulation rate, which controls reactor temperature and measures reaction heat demand, while increasing catalyst coking rates. Liquid product analyses included 2-dimensional gas chromatography time-of-flight mass spectroscopy (2D GCxGC TOFS), simulated distillation (SIM DIST), 13C NMR, and carbonyl content. Aggregated results indicated that the model compounds were converted during reaction, and despite functional group differences, product distributions for each model compound were very similar. In addition, we determined that adding model compounds to the VGO feed did not significantly affect the DCR's operability or performance. Future work will assess catalytic upgrading of biomass pyrolysis vapor to fungible hydrocarbon products using upgrading catalysts currently being developed at NREL and at Johnson Matthey.« less

  1. IODP Expedition 337: Deep Coalbed Biosphere off Shimokita - Microbial processes and hydrocarbon system associated with deeply buried coalbed in the ocean

    NASA Astrophysics Data System (ADS)

    Inagaki, Fumio; Hinrichs, Kai-Uwe; Kubo, Yusuke; IODP Expedition 337 Scientists

    2016-06-01

    The Integrated Ocean Drilling Program (IODP) Expedition 337 was the first expedition dedicated to subseafloor microbiology that used riser-drilling technology with the drilling vessel Chikyu. The drilling Site C0020 is located in a forearc basin formed by the subduction of the Pacific Plate off the Shimokita Peninsula, Japan, at a water depth of 1180 m. Primary scientific objectives during Expedition 337 were to study the relationship between the deep microbial biosphere and a series of ˜ 2 km deep subseafloor coalbeds and to explore the limits of life in the deepest horizons ever probed by scientific ocean drilling. To address these scientific objectives, we penetrated a 2.466 km deep sedimentary sequence with a series of lignite layers buried around 2 km below the seafloor. The cored sediments, as well as cuttings and logging data, showed a record of dynamically changing depositional environments in the former forearc basin off the Shimokita Peninsula during the late Oligocene and Miocene, ranging from warm-temperate coastal backswamps to a cool water continental shelf. The occurrence of small microbial populations and their methanogenic activity were confirmed down to the bottom of the hole by microbiological and biogeochemical analyses. The factors controlling the size and viability of ultra-deep microbial communities in those warm sedimentary habitats could be the increase in demand of energy and water expended on the enzymatic repair of biomolecules as a function of the burial depth. Expedition 337 provided a test ground for the use of riser-drilling technology to address geobiological and biogeochemical objectives and was therefore a crucial step toward the next phase of deep scientific ocean drilling.

  2. Real-time drilling mud gas monitoring for qualitative evaluation of hydrocarbon gas composition during deep sea drilling in the Nankai Trough Kumano Basin.

    PubMed

    Hammerschmidt, Sebastian B; Wiersberg, Thomas; Heuer, Verena B; Wendt, Jenny; Erzinger, Jörg; Kopf, Achim

    2014-01-01

    Integrated Ocean Drilling Program Expedition 338 was the second scientific expedition with D/V Chikyu during which riser drilling was conducted as part of the Nankai Trough Seismogenic Zone Experiment. Riser drilling enabled sampling and real-time monitoring of drilling mud gas with an onboard scientific drilling mud gas monitoring system ("SciGas"). A second, independent system was provided by Geoservices, a commercial mud logging service. Both systems allowed the determination of (non-) hydrocarbon gas, while the SciGas system also monitored the methane carbon isotope ratio (δ(13)CCH4). The hydrocarbon gas composition was predominated by methane (> 1%), while ethane and propane were up to two orders of magnitude lower. δ(13)CCH4 values suggested an onset of thermogenic gas not earlier than 1600 meter below seafloor. This study aims on evaluating the onboard data and subsequent geological interpretations by conducting shorebased analyses of drilling mud gas samples. During shipboard monitoring of drilling mud gas the SciGas and Geoservices systems recorded up to 8.64% and 16.4% methane, respectively. Ethane and propane concentrations reached up to 0.03 and 0.013%, respectively, in the SciGas system, but 0.09% and 0.23% in the Geoservices data. Shorebased analyses of discrete samples by gas chromatography showed a gas composition with ~0.01 to 1.04% methane, 2 - 18 ppmv ethane, and 2 - 4 ppmv propane. Quadruple mass spectrometry yielded similar results for methane (0.04 to 4.98%). With δD values between -171‰ and -164‰, the stable hydrogen isotopic composition of methane showed little downhole variability. Although the two independent mud gas monitoring systems and shorebased analysis of discrete gas sample yielded different absolute concentrations they all agree well with respect to downhole variations of hydrocarbon gases. The data point to predominantly biogenic methane sources but suggest some contribution from thermogenic sources at depth, probably due to mixing. In situ thermogenic gas production at depths shallower 2000 mbsf is unlikely based on in situ temperature estimations between 81°C and 85°C and a cumulative time-temperature index of 0.23. In conclusion, the onboard SciGas data acquisition helps to provide a preliminary, qualitative evaluation of the gas composition, the in situ temperature and the possibility of gas migration.

  3. Garden Banks 388 subsea drilling/production template: Project management of a fast-track project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ledbetter, W.R.

    1995-10-01

    Enserch Exploration`s Garden Banks 388 development is a production scheme based around a floating drilling and production facility and subsea drilling/production template. The Floating Production Facility (FPF) is a converted semisubmersible drilling rig which will drill and product through a 24-well slot template. This development is located in Block 388 of the Garden Banks area in the Gulf of Mexico approximately 200 miles southwest of New Orleans. Louisiana. This production system is being installed in an area of known oil and gas reserves and will produce to a shallow water platform 54 miles away at Ewing Bank 315. The FPFmore » will be permanently moored on the surface above the template. The subsea template has been installed in 2,190 feet of water and will produce through a 2,000 foot free-standing production riser system to the FPF. The produced fluids are partially separated on the FPF before oil and gas are pumped through the template to export gathering lines which are connected to the shallow water facility.« less

  4. Methode des Rayons avec Calcul d’Intensite Appliquee a la Propagation Anormale (Method of Ray Intensity Calculation as Applied to Anomalous Propagation),

    DTIC Science & Technology

    1986-06-01

    D’INTENSITE 0 APPLIQUEE A LA PROPAGATION "ANORNALE" par D. Dion DEFENCE RESEARCH ESTABLISHMENT CENTRE DE RECHERCHES POUR LA DEFENSE VALCARTI ER 6- Tel: (418...faqon ils sont reli~s aux conditions atmosph~riques. Les ph~no- manes les plus importants A signaler sont les conduits et les "trous radio". En effet...6tant tr~s fr~quents en mer, 11 est d’int&rt pour la marine de rechercher des m~thodes simples permettant de les caract~riser. Des 6quations d’int

  5. FOP 2012 stop, Honey Lake fault, Doyle, CA

    USGS Publications Warehouse

    Gold, Ryan; Briggs, Richard W.; Crone, Anthony; Angster, Steve; Seitz, Gordon G.

    2012-01-01

    The Honey Lake fault system (HLFS) strikes north-northwestward across Long Valley near Doyle, CA and is part of a network of active, dextral strike-slip faults in the northern Walker Lane (Figure 1). Geologic investigations of a right-laterally offset terrace riser along the north bank of Long Valley Creek, which we refer to as site 1 (Figure 2), indicate a latest Quaternary slip rate of 1.1-2. 6 mm/yr [Wills and Borchardt, 1993] and 1.7 ± 0.6 mm/yr [Turner and others, 2008] (Table 1). These studies also document evidence of at least four post-6.8 ka surface-rupturing earthquakes at this site.

  6. Frontal Affinity Chromatography with Mass Spectrometry Detection for Probing Molecular Interactions. A New Mechanistic Approach for the Development of Detection & Identification and Medical Countermeasures Against CB Agents

    DTIC Science & Technology

    2005-10-01

    l’optimisation des composants les plus prometteurs pour la d~couverte des m~dicaments. La technique CAF-SM est capable de localiser et de caract~riser...technique d’avant-garde peut ainsi aiguiller ]a recherche biotechnologique A travers les domaines cl~s et 6liminer beaucoup d’ann6es d’exp6rimentation...A l’aveuglette »). Ceci permettra de rationaliser le concept et la mise au point dans des domaines tels que la bio- detection et l’identification

  7. Le TERS, ou comment obtenir une signature chimique à l'échelle nanométrique

    NASA Astrophysics Data System (ADS)

    Hsia, Patrick; Chaigneau, Marc

    2018-02-01

    Le TERS pour tip enhanced raman scattering, est une technique de pointe (dans tous les sens du terme) basée sur l'amplification du signal Raman relative à la résonance de plasmons de surface. Cette technique non-destructive, qui ne nécessite pas de marquage particulier, permet de caractériser un échantillon à l'échelle nanométrique. Le TERS s'impose aujourd'hui pour sonder les propriétés physico-chimiques des nanomatériaux et participer ainsi au développement de nouvelles applications dans le domaine des nanotechnologies.

  8. Down-flow moving-bed gasifier with catalyst recycle

    DOEpatents

    Halow, John S.

    1999-01-01

    The gasification of coal and other carbonaceous materials by an endothermic gasification reaction is achieved in the presence of a catalyst in a down-flow, moving-bed gasifier. Catalyst is removed along with ash from the gasifier and is then sufficiently heated in a riser/burner by the combustion of residual carbon in the ash to volatilize the catalyst. This volatilized catalyst is returned to the gasifier where it uniformly contacts and condenses on the carbonaceous material. Also, the hot gaseous combustion products resulting from the combustion of the carbon in the ash along with excess air are introduced into the gasifier for providing heat energy used in the endothermic reaction.

  9. The study of solid circulation rate in a compartmented fluidized bed gasifier (CFBG)

    NASA Astrophysics Data System (ADS)

    Wee, S. K.; Pok, Y. W.; Law, M. C.; Lee, V. C. C.

    2016-06-01

    Biomass waste has been abundantly available in Malaysia since the booming of palm oil industry. In order to tackle this issue, gasification is seen a promising technology to convert waste into energy. In view of the heat requirement for endothermic gasification reaction as well as the complex design and operation of multiple fluidized beds, compartmented fluidized bed gasifier (CFBG) with the combustor and the gasifier as separate compartments is proposed. As such, solid circulation rate (SCR) is one of the essential parameters for steady gasification and combustion to be realized in their respective compartments. Experimental and numerical studies (CFD) on the effect of static bed height, main bed aeration, riser aeration and v-valve aeration on SCR have been conducted in a cold- flow CFBG model with only river sand as the fluidizing medium. At lower operating range, the numerical simulations under-predict the SCR as compared to that of the experimental results. Also, it predicts slightly different trends over the range. On the other hand, at higher operating range, the numerical simulations are able to capture those trends as observed in the experimental results at the lower operating range. Overall, the numerical results compare reasonably well with that of the experimental works.

  10. Statistical Study to Evaluate the Effect of Processing Variables on Shrinkage Incidence During Solidification of Nodular Cast Irons

    NASA Astrophysics Data System (ADS)

    Gutiérrez, J. M.; Natxiondo, A.; Nieves, J.; Zabala, A.; Sertucha, J.

    2017-04-01

    The study of shrinkage incidence variations in nodular cast irons is an important aspect of manufacturing processes. These variations change the feeding requirements on castings and the optimization of risers' size is consequently affected when avoiding the formation of shrinkage defects. The effect of a number of processing variables on the shrinkage size has been studied using a layout specifically designed for this purpose. The β parameter has been defined as the relative volume reduction from the pouring temperature up to the room temperature. It is observed that shrinkage size and β decrease as effective carbon content increases and when inoculant is added in the pouring stream. A similar effect is found when the parameters selected from cooling curves show high graphite nucleation during solidification of cast irons for a given inoculation level. Pearson statistical analysis has been used to analyze the correlations among all involved variables and a group of Bayesian networks have been subsequently built so as to get the best accurate model for predicting β as a function of the input processing variables. The developed models can be used in foundry plants to study the shrinkage incidence variations in the manufacturing process and to optimize the related costs.

  11. Bedrock, soils, and hillslope hydrology in the Central Texas Hill Country, USA: implications on environmental management in a carbonate-rock terrain

    NASA Astrophysics Data System (ADS)

    Woodruff, C. M.; Wilding, L. P.

    2008-08-01

    The Hill Country of Central Texas, USA, is undergoing rapid socioeconomic development, but environmental management of this region is hampered by misconceptions about local bedrock, soils, terrain, and hydrologic processes. The Hill Country is underlain mostly by Glen Rose Limestone (Lower Cretaceous) and exhibits a stepped terrain, which has been incorrectly attributed to alternating hard and soft bedrock strata. Other characteristics mistakenly attributed to this landscape include thin soils with scant water-retention capabilities, and rapid runoff as the dominant hydrologic process. This report presents new findings: unweathered bedrock is well indurated, but interbeds exhibit variable weathering rates. Recessive slopes (“risers”) on this stepped terrain result from rapid deterioration of strata having generally heterogeneous depositional fabrics (bioturbation and irregular clay partings) in contrast to ledge-forming strata having homogeneous fabrics. A stony regolith is thus formed beneath risers, providing porous and permeable ground that retards runoff and promotes the formation of moderately deep to deep (two-tiered) regolith/soil zones. These surficial materials on local steep slopes compose important natural environmental buffers; they support diverse biota and enhanced geochemical cycling of nutrients; they also exhibit significant water retention and enhanced erosion abatement. Proper land management demands recognition of these attributes in the siting, design, and construction of facilities.

  12. Borehole instability analysis for IODP Site C0002 of the NanTroSEIZE Project, Nankai Trough subduction zone

    NASA Astrophysics Data System (ADS)

    Wu, H.; Kido, Y. N.; Kinoshita, M.; Saito, S.

    2013-12-01

    Wellbore instability is a major challenge for the engineer evaluating borehole and formation conditions. Instability is especially important to understand in areas with high stress variations, significant structure anisotropy, or pre-existing fracture systems. Borehole (in)stability is influenced by rock strength, structural properties, and near-field principal stresses. During drilling, the borehole conditions also impact borehole integrity. Factors that we can measure in the borehole during with logging while drilling (LWD) to understand these conditions include mud weight, mud loss, ROP (Rate of Penetration), RPM (Rotation Per Minute), WOB (Weight on Bit), and TORQ (Power swivel torque value). We conducted borehole instability analysis for Site C0002 of the Nankai Trough transect based on riser and riserless drilling during IODP Expedition 338. The borehole shape, determined from LWD resistivity images, indicates that most of drilling occurred in stable environments, however, in a few instances the bottom hole assembly became stuck. We used our stress profile model to evaluate the mud weight required to drill a stable borehole for the estimated rock strength and physical properties. Based on our analysis, we interpret that borehole instability during IODP Expedition 338 may have been caused by weak bedding plane and fluid overpressure state. Future work with this model will investigate the roles of these conditions.

  13. Retrieval System for Calcined Waste for the Idaho Cleanup Project - 12104

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eastman, Randy L.; Johnston, Beau A.; Lower, Danielle E.

    This paper describes the conceptual approach to retrieve radioactive calcine waste, hereafter called calcine, from stainless steel storage bins contained within concrete vaults. The retrieval system will allow evacuation of the granular solids (calcine) from the storage bins through the use of stationary vacuum nozzles. The nozzles will use air jets for calcine fluidization and will be able to rotate and direct the fluidization or displacement of the calcine within the bin. Each bin will have a single retrieval system installed prior to operation to prevent worker exposure to the high radiation fields. The addition of an articulated camera armmore » will allow for operations monitoring and will be equipped with contingency tools to aid in calcine removal. Possible challenges (calcine bridging and rat-holing) associated with calcine retrieval and transport, including potential solutions for bin pressurization, calcine fluidization and waste confinement, are also addressed. The Calcine Disposition Project has the responsibility to retrieve, treat, and package HLW calcine. The calcine retrieval system has been designed to incorporate the functions and technical characteristics as established by the retrieval system functional analysis. By adequately implementing the highest ranking technical characteristics into the design of the retrieval system, the system will be able to satisfy the functional requirements. The retrieval system conceptual design provides the means for removing bulk calcine from the bins of the CSSF vaults. Top-down vacuum retrieval coupled with an articulating camera arm will allow for a robust, contained process capable of evacuating bulk calcine from bins and transporting it to the processing facility. The system is designed to fluidize, vacuum, transport and direct the calcine from its current location to the CSSF roof-top transport lines. An articulating camera arm, deployed through an adjacent access riser, will work in conjunction with the retrieval nozzle to aid in calcine fluidization, remote viewing, clumped calcine breaking and recovery from off-normal conditions. As the design of the retrieval system progresses from conceptual to preliminary, increasing attention will be directed toward detailed design and proof-of- concept testing. (authors)« less

  14. COMMERCIALIZATION OF AN ATMOSPHERIC IRON-BASED CDCL PROCESS FOR POWER PRODUCTION. PHASE I: TECHNOECONOMIC ANALYSIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vargas, Luis

    Coal Direct Chemical Looping (CDCL) is an advanced oxy-combustion technology that has potential to enable substantial reductions in the cost and energy penalty associated with carbon dioxide (CO2) capture from coal-fired power plants. Through collaborative efforts, the Babcock & Wilcox Power Generation Group (B&W) and The Ohio State University (OSU) developed a conceptual design for a 550 MWe (net) supercritical CDCL power plant with greater than 90% CO2 capture and compression. Process simulations were completed to enable an initial assessment of its technical performance. A cost estimate was developed following DOE’s guidelines as outlined in NETL’s report “Quality Guidelines formore » Energy System Studies: Cost Estimation Methodology for NETL Assessments of Power Plant Performance”, (2011/1455). The cost of electricity for the CDCL plant without CO2 Transportation and Storage cost resulted in $ $102.67 per MWh, which corresponds to a 26.8 % increase in cost of electricity (COE) when compared to an air-fired pulverized-coal supercritical power plant. The cost of electricity is strongly depending on the total plant cost and cost of the oxygen carrier particles. The CDCL process could capture further potential savings by increasing the performance of the particles and reducing the plant size. During the techno-economic analysis, the team identified technology and engineering gaps that need to be closed to bring the technology to commercialization. The technology gaps were focused in five critical areas: (i) moving bed reducer reactor, (ii) fluidized bed combustor, (iii) particle riser, (iv) oxygen-carrier particle properties, and (v) process operation. The key technology gaps are related to particle performance, particle manufacturing cost, and the operation of the reducer reactor. These technology gaps are to be addressed during Phase II of project. The project team is proposing additional lab testing to be completed on the particle and a 3MWth pilot facility be built to evaluate the reducer reactor performance among other aspects of the technology. A Phase II proposal was prepared and submitted to DOE. The project team proposed a three year program in Phase II. Year 1 includes lab testing and particle development work aimed at improving the chemical and mechanical properties of the oxygen carrier particle. In parallel, B&W will design the 3MWt pilot plant. Any improvements to the particle performance discovered in year 1 that would impact the design of the pilot will be incorporated into the final design. Year 2 will focus on procurement of materials and equipment, and construction of the pilot plant. Year 3 will include, commissioning, start-up, and testing in the pilot. Phase I work was successfully completed and a design and operating philosophy for a 550 MWe commercial scale coal-direct chemical looping power plant was developed. Based on the results of the techno-economic evaluation, B&W projects that the CDCL process can achieve 96.5% CO2 capture with a« less

  15. Progress in Hanford's Double-Shell Tank Integrity Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryson, D.C.; Washenfelder, D.J.; Boomer, K.D.

    2008-07-01

    The U.S. Department of Energy's Office of River Protection has an extensive integrity assessment program for the Hanford Site Double-Shell Tank System. The DOE Orders and environmental protection regulations provide the guidelines for the activities used to inspect and maintain 28 double-shell tanks (DSTs), the waste evaporator, and ancillary equipment that compose this system. This program has been reviewed by oversight and regulatory bodies and found to comply with the established guidelines. The basis for the DOE Order 435.1-1 for tank integrity comes from the Tank Structural Integrity Panel led by Brookhaven National Laboratory during the late 1990's. These guidelinesmore » established criteria for performing Non-Destructive Examination (NDE), for acceptance of the NDE results, for waste chemistry control, and for monitoring the tanks. The environmental regulations mirror these requirements and allow for the tank integrity program to provide compliant storage of the tanks. Both sets of requirements provide additional guidance for the protection of ancillary equipment. CH2M HILL uses two methods of NDE: visual inspection and Ultrasonic Testing (UT). The visual inspection program examines the primary tank and secondary liner of the DST. The primary tank is examined both on the interior surface above the waste in the tank and on the exterior surface facing the annulus of the DST. The interior surface of the tank liner is examined at the same time as the outer surface of the primary tank. The UT program examines representative areas of the primary tank and secondary liner by deploying equipment in the annulus of the tank. Both programs have led to the development of new equipment for remote inspection of the tanks. Compact camera and enhanced lighting systems have been designed and deployed through narrow access ports (called risers) into the tanks. The UT program has designed two generations of crawlers and equipment for deployment through risers into the thermally hot and radioactive environment. Also extensions were developed to allow inspection of the tank's curve upper (haunch) and lower (knuckle) surfaces. CH2M HILL primarily maintains chemistry control of the DST by ensuring that the concentrations of hydroxide and nitrite ions are favorable with respect to the nitrate ion concentration in the waste. This control program is supported by an extensive sampling program that obtains samples from the supernatant and solid layers in the tank to ensure compliance with the chemical specification. At DOE direction, CH2M HILL has embarked on a waste chemistry optimization program to enhance the protection of the tank surface and the understanding of the parameters that affect general and localized corrosion in the tanks. Over the past decade, DOE has deployed Electrochemical Noise corrosion probes in the DST to monitor localized corrosion. From the information gathered as part of the chemistry control, new information has been identified about the parameters requiring control to ensure tank integrity. CH2M HILL is deploying a series of corrosion probes to test and employ these parameters to provide real time corrosion monitoring of the DSTs. (authors)« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gavignet, A.A.; Wick, C.J.

    In current practice, pressure drops in the mud circulating system and the settling velocity of cuttings are calculated with simple rheological models and simple equations. Wellsite computers now allow more sophistication in drilling computations. In this paper, experimental results on the settling velocity of spheres in drilling fluids are reported, along with rheograms done over a wide range of shear rates. The flow curves are fitted to polynomials and general methods are developed to predict friction losses and settling velocities as functions of the polynomial coefficients. These methods were incorporated in a software package that can handle any rig configurationmore » system, including riser booster. Graphic displays show the effect of each parameter on the performance of the circulating system.« less

  17. Tank 241-U-103, grab samples 3U-99-1, 3u-99-2 and 3U-99-3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    STEEN, F.H.

    This document is the final report for tank 241-U-103 grab samples. Three grab samples were collected from riser 13 on March 12, 1999 and received by the 222-S laboratory on March 15, 1999. Analyses were performed in accordance with the Compatibility Grab Sampling and Analysis Plan for Fiscal year 1999 (TSAP) and the Data Quality Objectives for Tank Farms Waste Compatibility Program (DQO). The analytical results are presented in the data summary report. None of the subsamples submitted for differential scanning calorimetry (DSC), total organic carbon (TOC) and plutonium 239 (Pu239) analyses exceeded the notification limits as stated in TSAP.

  18. Down-flow moving-bed gasifier with catalyst recycle

    DOEpatents

    Halow, J.S.

    1999-04-20

    The gasification of coal and other carbonaceous materials by an endothermic gasification reaction is achieved in the presence of a catalyst in a down-flow, moving-bed gasifier. Catalyst is removed along with ash from the gasifier and is then sufficiently heated in a riser/burner by the combustion of residual carbon in the ash to volatilize the catalyst. This volatilized catalyst is returned to the gasifier where it uniformly contacts and condenses on the carbonaceous material. Also, the hot gaseous combustion products resulting from the combustion of the carbon in the ash along with excess air are introduced into the gasifier for providing heat energy used in the endothermic reaction. 1 fig.

  19. Tank 241-AN-101, grab samples, 1AN-98-1, 1AN-98-2 and 1AN-98-3 analytical results for the final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    FULLER, R.K.

    1999-02-24

    This document is the final report for tank 241-AN-101 grab samples. Three grab samples 1AN-98-1, 1AN-98-2 and 1AN-98-3 were taken from riser 16 of tank 241-AN-101 on April 8, 1998 and received by the 222-S Laboratory on April 9, 1998. Analyses were performed in accordance with the ''Compatability Grab Sampling and Analysis Plan'' (TSAP) and the ''Data Quality Objectives for Tank Farms Waste Compatability Program'' (DQO). The analytical results are presented in the data summary report. No notification limits were exceeded.

  20. Water Deluge Test at Pad 39B

    NASA Image and Video Library

    2018-05-24

    About 450,000 gallons of water flow at high speed from a holding tank through new and modified piping and valves, the flame trench, flame deflector nozzles and mobile launcher interface risers during a wet flow test on May 24, 2018, at Launch Pad 39B at NASA's Kennedy Space Center in Florida. At peak flow, the water reached about 100 feet in the air above the pad surface. The test was performed by Exploration Ground Systems to confirm the performance of the Ignition Overpressure/Sound Suppression system. During launch of NASA's Space Launch System rocket and Orion spacecraft, the high-speed water flow will help protect the vehicle from the extreme acoustic and temperature environment during ignition and liftoff.

Top