Innovative approach to reduction of waste streams for cutting operations in remote environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skibo, A.
SRNL proposes to develop and demonstrate an approach using the SRNL rotary microfilter (RMF) technology for reducing waste streams in remote cutting operations during decontamination operations. SRNL offers to collaborate with Tokyo Electric Power Company (TEPCO) in evaluation, testing, and utilization of SRNL’s radiation-hardened rotary microfilter in the deactivation and decommissioning (D&D) operations of the Fukushima Daiichi Nuclear Power Station (NPS). Refinement of the scope and associated costs will be conducted in consultation with TEPCO.
DEVELOPMENT OF A LAMINATED DISK FOR THE SPIN TEK ROTARY MICROFILTER
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herman, D.
2011-06-03
Funded by the Department of Energy Office of Environmental Management, EM-31, the Savannah River National Laboratory (SRNL) partnered with SpinTek Filtration{trademark} to develop a filter disk that would withstand a reverse pressure or flow during operation of the rotary microfilter. The ability to withstand a reverse pressure and flow eliminates a potential accident scenario that could have resulted in damage to the filter membranes. While the original welded filter disks have been shown to withstand and reverse pressure/flow in the static condition, the filter disk design discussed in this report will allow a reverse pressure/flow while the disks are rotating.more » In addition, the laminated disk increases the flexibility during filter startup and cleaning operations. The new filter disk developed by SRNL and SpinTek is manufactured with a more open structure significantly reducing internal flow restrictions in the disk. The prototype was tested at the University of Maryland and demonstrated to withstand the reverse pressure due to the centrifugal action of the rotary filter. The tested water flux of the disk was demonstrated to be 1.34 gpm in a single disk test. By comparison, the water flux of the current disk was 0.49 gpm per disk during a 25 disk test. The disk also demonstrated rejection of solids by filtering a 5 wt % Strontium Carbonate slurry with a filtrate clarity of less the 1.4 Nephelometric Turbidity Units (NTU) throughout the two hour test. The Savannah River National Laboratory (SRNL) has been working with SpinTek Filtration{trademark} to adapt the rotary microfilter for radioactive service in the Department of Energy (DOE) Complex. One potential weakness is the loose nature of the membrane on the filter disks. The current disk is constructed by welding the membrane at the outer edge of the disk. The seal for the center of the membrane is accomplished by an o-ring in compression for the assembled stack. The remainder of the membrane is free floating on the disk. This construction requires that a positive pressure be applied to the rotary filter tank to prevent the membrane from rising from the disk structure and potentially contacting the filter turbulence promoter. In addition, one accident scenario is a reverse flow through the filtrate line due to mis-alignment of valves resulting in the membrane rising from the disk structure. The structural integrity of the current disk has been investigated, and shown that the disk can withstand a significant reverse pressure in a static condition. However, the disk will likely incur damage if the filter stack is rotated during a reverse pressure. The development of a laminated disk would have several significant benefits for the operation of the rotary filter including the prevention of a compromise in filter disk integrity during a reverse flow accident, increasing operational flexibility, and increasing the self cleaning ability of the filter. A laminated disk would allow the filter rotor operation prior to a positive pressure in the filter tank. This would prevent the initial dead-head of the filter and prevent the resulting initial filter cake buildup. The laminated disk would allow rotor operation with cleaning fluid, eliminating the need for a recirculation pump. Additionally, a laminated disk would allow a reverse flow of fluid through the membrane pores removing trapped particles.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eric S. Peterson; Jessica Trudeau; Bill Cleary
An active-surface membrane technology was used to separate a die lube manufacturing wastewater stream consisting of various oils, hydrocarbons, heavy metals, and silicones. The ultrafiltration membranes reduced organics from initial oil and grease contents by 20–25X, carbon oxygen demand (COD) by 1.5 to 2X, and total organic carbon (TOC) by 0.6, while the biological oxygen demand (BOD) remained constant. The active-surface membranes were not fouled as badly as non-active-surface systems and the active-surface membrane flux levels were consistently higher and more stable than those of the non-active-surface membranes tested. Field testing demonstrated that the rotary microfilter can concentrate the diemore » lube, i.e. remove the glycerin component, and produce a die lube suitable for recycling. The recycling system operated for six weeks with only seven cleaning cycles and no mechanical or electrical failures. Test data and quality records indicate that the die casting scrap was reduced from 8.4 to 7.8%. There is no doubt that this test yielded tremendous results. This separation process presents significant opportunities that can be evaluated further.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peterson, E. S.; Trudeau, J.; Cleary, B.
An active-surface membrane technology was used to separate a die lube manufacturing wastewater stream consisting of various oils, hydrocarbons, heavy metals, and silicones. The ultrafiltration membranes reduced organics from initial oil and grease contents by 20-25X, carbon oxygen demand (COD) by 1.5 to 2X, and total organic carbon (TOC) by 0.6, while the biological oxygen demand (BOD) remained constant. The active-surface membranes were not fouled as badly as non-active-surface systems and the active-surface membrane flux levels were consistently higher and more stable than those of the non-active-surface membranes tested. Field testing demonstrated that the rotary microfilter can concentrate the diemore » lube, i.e. remove the glycerin component, and produce a die lube suitable for recycling. The recycling system operated for six weeks with only seven cleaning cycles and no mechanical or electrical failures. Test data and quality records indicate that the die casting scrap was reduced from 8.4 to 7.8%. There is no doubt that this test yielded tremendous results. This separation process presents significant opportunities that can be evaluated further.« less
NASA Astrophysics Data System (ADS)
Zhou, Ming-Da; Hao, Sijie; Williams, Anthony J.; Harouaka, Ramdane A.; Schrand, Brett; Rawal, Siddarth; Ao, Zheng; Brennaman, Randall; Gilboa, Eli; Lu, Bo; Wang, Shuwen; Zhu, Jiyue; Datar, Ram; Cote, Richard; Tai, Yu-Chong; Zheng, Si-Yang
2014-12-01
The analysis of circulating tumour cells (CTCs) in cancer patients could provide important information for therapeutic management. Enrichment of viable CTCs could permit performance of functional analyses on CTCs to broaden understanding of metastatic disease. However, this has not been widely accomplished. Addressing this challenge, we present a separable bilayer (SB) microfilter for viable size-based CTC capture. Unlike other single-layer CTC microfilters, the precise gap between the two layers and the architecture of pore alignment result in drastic reduction in mechanical stress on CTCs, capturing them viably. Using multiple cancer cell lines spiked in healthy donor blood, the SB microfilter demonstrated high capture efficiency (78-83%), high retention of cell viability (71-74%), high tumour cell enrichment against leukocytes (1.7-2 × 103), and widespread ability to establish cultures post-capture (100% of cell lines tested). In a metastatic mouse model, SB microfilters successfully enriched viable mouse CTCs from 0.4-0.6 mL whole mouse blood samples and established in vitro cultures for further genetic and functional analysis. Our preliminary studies reflect the efficacy of the SB microfilter device to efficiently and reliably enrich viable CTCs in animal model studies, constituting an exciting technology for new insights in cancer research.
Polymer microfilters with nanostructured surfaces for the culture of circulating cancer cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makarova, Olga V.; Adams, Daniel L.; Divan, Ralu
There is a critical need to improve the accuracy of drug screening and testing through the development of in vitro culture systems that more effectively mimic the in vivo environment. Surface topographical features on the nanoscale level, in short nanotopography, effect the cell growth patterns, and hence affect cell function in culture. We report the preliminary results on the fabrication, and subsequent cellular growth, of nanoscale surface topography on polymer microfilters using cell lines as a precursor to circulating tumor cells (CTCs). To create various nanoscale features on the microfilter surface, we used reactive ion etching (RIE) with and withoutmore » an etching mask. An anodized aluminum oxide (AAO) membrane fabricated directly on the polymer surface served as an etching mask. Polymer filters with a variety of modified surfaces were used to compare the effects on the culture of cancer cell lines in blank culture wells, with untreated microfilters or with RIE-treated microfilters. We then report the differences of cell shape, phenotype and growth patterns of bladder and glioblastoma cancer cell lines after isolation on the various types of material modifications. Our data suggest that RIE modified polymer filters can isolate model cell lines while retaining ell viability, and that the RIE filter modification allows T24 monolayering cells to proliferate as a structured cluster. Copyright 2016 The Authors. Published by Elsevier B.V. All rights reserved.« less
Ceramic membrane microfilter as an immobilized enzyme reactor.
Harrington, T J; Gainer, J L; Kirwan, D J
1992-10-01
This study investigated the use of a ceramic microfilter as an immobilized enzyme reactor. In this type of reactor, the substrate solution permeates the ceramic membrane and reacts with an enzyme that has been immobilized within its porous interior. The objective of this study was to examine the effect of permeation rate on the observed kinetic parameters for the immobilized enzyme in order to assess possible mass transfer influences or shear effects. Kinetic parameters were found to be independent of flow rate for immobilized penicillinase and lactate dehydrogenase. Therefore, neither mass transfer nor shear effects were observed for enzymes immobilized within the ceramic membrane. Both the residence time and the conversion in the microfilter reactor could be controlled simply by regulating the transmembrane pressure drop. This study suggests that a ceramic microfilter reactor can be a desirable alternative to a packed bed of porous particles, especially when an immobilized enzyme has high activity and a low Michaelis constant.
Tissier, Adeline; Denis, Martine; Hartemann, Philippe; Gassilloud, Benoît
2012-02-01
Investigations of Campylobacter jejuni and Campylobacter coli in samples of drinking water suspected of being at the origin of an outbreak very often lead to negative results. One of the reasons for this failure is the small volume of water typically used for detecting these pathogens (10 to 1,000 ml). The efficiencies of three microfilters and different elution procedures were determined using real-time quantitative PCR to propose a procedure allowing detection of Campylobacter in 20 liters of drinking water or low-turbidity water samples. The results showed that more than 80% of the bacteria inoculated in 1 liter of drinking water were retained on each microfilter. An elution with a solution containing 3% beef extract, 0.05 M glycine at pH 9, combined with direct extraction of the bacterial genomes retained on the cellulose ester microfilter, allowed recovery of 87.3% (±22% [standard deviation]) of Campylobacter per 1 liter of tap water. Recoveries obtained from 20-liter volumes of tap water spiked with a C. coli strain were 69.5% (±10.3%) and 78.5% (±15.1%) for 91 CFU and 36 CFU, respectively. Finally, tests performed on eight samples of 20 liters of groundwater collected from an alluvial well used for the production of drinking water revealed the presence of C. jejuni and C. coli genomes, whereas no bacteria were detected with the normative culture method in volumes ranging from 10 to 1,000 ml. In the absence of available epidemiological data and information on bacterial viability, these last results indicate only that the water resource is not protected from contamination by Campylobacter.
Tissier, Adeline; Denis, Martine; Hartemann, Philippe
2012-01-01
Investigations of Campylobacter jejuni and Campylobacter coli in samples of drinking water suspected of being at the origin of an outbreak very often lead to negative results. One of the reasons for this failure is the small volume of water typically used for detecting these pathogens (10 to 1,000 ml). The efficiencies of three microfilters and different elution procedures were determined using real-time quantitative PCR to propose a procedure allowing detection of Campylobacter in 20 liters of drinking water or low-turbidity water samples. The results showed that more than 80% of the bacteria inoculated in 1 liter of drinking water were retained on each microfilter. An elution with a solution containing 3% beef extract, 0.05 M glycine at pH 9, combined with direct extraction of the bacterial genomes retained on the cellulose ester microfilter, allowed recovery of 87.3% (±22% [standard deviation]) of Campylobacter per 1 liter of tap water. Recoveries obtained from 20-liter volumes of tap water spiked with a C. coli strain were 69.5% (±10.3%) and 78.5% (±15.1%) for 91 CFU and 36 CFU, respectively. Finally, tests performed on eight samples of 20 liters of groundwater collected from an alluvial well used for the production of drinking water revealed the presence of C. jejuni and C. coli genomes, whereas no bacteria were detected with the normative culture method in volumes ranging from 10 to 1,000 ml. In the absence of available epidemiological data and information on bacterial viability, these last results indicate only that the water resource is not protected from contamination by Campylobacter. PMID:22138985
NASA Astrophysics Data System (ADS)
Gu, Ye; Miki, Norihisa
2009-06-01
We present a multilayered microfilter for use as a dialyzer of a wearable artificial kidney separating metabolic wastes such as urea, uric acid and creatinine from blood. The microfilter device is assembled by alternately bonding chamber layers made of Ti by wet etching and semipermeable polymeric membranes made of polyethersulfone (PES) by the wet phase inversion method. The PES membranes sandwiched between each two chamber layers act as barriers to molecules larger than 1.7 nm. The multilayered microfilter was geometrically optimized with respect to our theoretical equations and experimental results in order to obtain kidney-competitive performance. Each diffusing unit of our device, which is only 24 × 24 × 0.4 mm3 in size, was proved experimentally to be capable of allowing a flow rate of up to 1 ml min-1 under an input pressure of only 10 kPa, which is the hydrostatic pressure in human renal arteries, while having a urea removal rate of 18 µg min-1.
Microbial quality of drinking water from microfiltered water dispensers.
Sacchetti, R; De Luca, G; Dormi, A; Guberti, E; Zanetti, F
2014-03-01
A comparison was made between the microbial quality of drinking water obtained from Microfiltered Water Dispensers (MWDs) and that of municipal tap water. A total of 233 water samples were analyzed. Escherichia coli (EC), enterococci (ENT), total coliforms (TC), Staphylococcus aureus, Pseudomonas aeruginosa and heterotrophic plate count (HPC) at 22 °C and 37 °C were enumerated. In addition, information was collected about the principal structural and functional characteristics of each MWD in order to study the various factors that might influence the microbial quality of the water. EC and ENT were not detected in any of the samples. TC were never detected in the tap water but were found in 5 samples taken from 5 different MWDs. S. aureus was found in a single sample of microfiltered water. P. aeruginosa was found more frequently and at higher concentrations in the samples collected from MWDs. The mean HPCs at 22 °C and 37 °C were significantly higher in microfiltered water samples compared to those of the tap water. In conclusion, the use of MWDs may increase the number of bacteria originally present in tap water. It is therefore important to monitor the quality of the dispensed water over time, especially if it is destined for vulnerable users. Copyright © 2013 Elsevier GmbH. All rights reserved.
2015-06-01
DNA hybridization using fluorescence,” Biopolymers 95(7), 472–486 (2011). 26. J.-L. Mergny and L. Lacroix, “Analysis of thermal melting curves...Microfilter Platform PRINCIPAL INVESTIGATOR: Gregory W. Faris, Ph.D. CONTRACTING ORGANIZATION : SRI International Menlo Park, CA 94025 REPORT DATE...Ph.D. 5e. TASK NUMBER E-Mail: ! ! 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) SRI International AND ADDRESS(ES) 8
A review of Curtiss-Wright rotary engine developments with respect to general aviation potential
NASA Technical Reports Server (NTRS)
Jones, C.
1979-01-01
Aviation related rotary (Wankel-type) engine tests, possible growth directions and relevant developments at Curtiss-Wright have been reviewed. Automotive rotary engines including stratified charge are described and flight test results of rotary aircraft engines are presented. The current 300 HP engine prototype shows basic durability and competitive performance potential. Recent parallel developments have separately confirmed the geometric advantages of the rotary engine for direct injected unthrottled stratified charge. Specific fuel consumption equal to or better than pre- or swirl-chamber diesels, low emission and multi-fuel capability have been shown by rig tests of similar rotary engine.
Multichannel microfluidic chip for rapid and reliable trapping and imaging plant-parasitic nematodes
NASA Astrophysics Data System (ADS)
Amrit, Ratthasart; Sripumkhai, Witsaroot; Porntheeraphat, Supanit; Jeamsaksiri, Wutthinan; Tangchitsomkid, Nuchanart; Sutapun, Boonsong
2013-05-01
Faster and reliable testing technique to count and identify nematode species resided in plant roots is therefore essential for export control and certification. This work proposes utilizing a multichannel microfluidic chip with an integrated flow-through microfilter to retain the nematodes in a trapping chamber. When trapped, it is rather simple and convenient to capture images of the nematodes and later identify their species by a trained technician. Multiple samples can be tested in parallel using the proposed microfluidic chip therefore increasing number of samples tested per day.
Montet, M P; Jamet, E; Ganet, S; Dizin, M; Miszczycha, S; Dunière, L; Thevenot, D; Vernozy-Rozand, C
2009-01-01
Growth and survival of acid-resistant (AR) and non-acid-resistant (NAR) Shiga-toxin-producing Escherichia coli (STEC) strains were investigated during the manufacture and ripening of microfiltered milk Camembert cheeses. The induction of acid resistance of the STEC strains in cheeses was also studied. Six different mixtures of AR and/or NAR STEC strains were inoculated separately into microfiltered milk at a level of 10(3) CFU mL(-1). The STEC counts (AR and NAR) initially increased by 1 to 2 log(10) CFU g(-1) during cheese-making. Thereafter, the populations stabilized during salting/drying and then decreased during the early stages of ripening. Exposing the STEC strains in artificially inoculated cheeses to simulated gastric fluid (SGF - pH: 2.0) reduced the number of NAR strains to undetectable levels within 40 minutes, versus 120 minutes for the AR STEC strains. AR and NAR STEC were able to survive during the manufacture and ripening of Camembert cheese prepared from microfiltered milk with no evidence of induced acid tolerance in NAR STEC strains.
Non-Destructive Inspection Methods for Propulsion Systems and Components
1979-04-01
debris on a microfilter, followed by X-ray examination of the deposits and atomic absorption analysis of the deposits dissolved in hydrochloric acid ...thickness. A single naphthenic mineral oil was used for all tests in a once through system to avoid particle contamination. It was found that: the total...Superalliage. Alliage nickel. Acier inoxydable. Mesure expdrimentale. Transformation phase. Oxydation . Carbonisation. Aube turbine. Ddtection ddfaut. Contr6le
NASA Technical Reports Server (NTRS)
Allred, J. W.; Fleck, V. J.
1992-01-01
A new lightweight Rotary Balance System is presently being fabricated and installed as part of a major upgrade to the existing 20 Foot Vertical Spin Tunnel. This upgrade to improve model testing productivity of the only free spinning vertical wind tunnel includes a modern fan/drive and tunnel control system, an updated video recording system, and the new rotary balance system. The rotary balance is a mechanical apparatus which enables the measurement of aerodynamic force and moment data under spinning conditions (100 rpm). This data is used in spin analysis and is vital to the implementation of large amplitude maneuvering simulations required for all new high performance aircraft. The new rotary balance system described in this report will permit greater test efficiency and improved data accuracy. Rotary Balance testing with the model enclosed in a tare bag can also be performed to obtain resulting model forces from the spinning operation. The rotary balance system will be stored against the tunnel sidewall during free flight model testing.
An overview of the NASA rotary engine research program
NASA Technical Reports Server (NTRS)
Meng, P. R.; Hady, W. F.
1984-01-01
A brief overview and technical highlights of the research efforts and studies on rotary engines over the last several years at the NASA Lewis Research Center are presented. The test results obtained from turbocharged rotary engines and preliminary results from a high performance single rotor engine were discussed. Combustion modeling studies of the rotary engine and the use of a Laser Doppler Velocimeter to confirm the studies were examined. An in-house program in which a turbocharged rotary engine was installed in a Cessna Skymaster for ground test studies was reviewed. Details are presented on single rotor stratified charge rotary engine research efforts, both in-house and on contract.
Montet, M. P.; Jamet, E.; Ganet, S.; Dizin, M.; Miszczycha, S.; Dunière, L.; Thevenot, D.; Vernozy-Rozand, C.
2009-01-01
Growth and survival of acid-resistant (AR) and non-acid-resistant (NAR) Shiga-toxin-producing Escherichia coli (STEC) strains were investigated during the manufacture and ripening of microfiltered milk Camembert cheeses. The induction of acid resistance of the STEC strains in cheeses was also studied. Six different mixtures of AR and/or NAR STEC strains were inoculated separately into microfiltered milk at a level of 103 CFU mL−1. The STEC counts (AR and NAR) initially increased by 1 to 2 log10 CFU g−1 during cheese-making. Thereafter, the populations stabilized during salting/drying and then decreased during the early stages of ripening. Exposing the STEC strains in artificially inoculated cheeses to simulated gastric fluid (SGF - pH: 2.0) reduced the number of NAR strains to undetectable levels within 40 minutes, versus 120 minutes for the AR STEC strains. AR and NAR STEC were able to survive during the manufacture and ripening of Camembert cheese prepared from microfiltered milk with no evidence of induced acid tolerance in NAR STEC strains. PMID:20016668
Rotary Balance Wind Tunnel Testing for the FASER Flight Research Aircraft
NASA Technical Reports Server (NTRS)
Denham, Casey; Owens, D. Bruce
2016-01-01
Flight dynamics research was conducted to collect and analyze rotary balance wind tunnel test data in order to improve the aerodynamic simulation and modeling of a low-cost small unmanned aircraft called FASER (Free-flying Aircraft for Sub-scale Experimental Research). The impetus for using FASER was to provide risk and cost reduction for flight testing of more expensive aircraft and assist in the improvement of wind tunnel and flight test techniques, and control laws. The FASER research aircraft has the benefit of allowing wind tunnel and flight tests to be conducted on the same model, improving correlation between wind tunnel, flight, and simulation data. Prior wind tunnel tests include a static force and moment test, including power effects, and a roll and yaw damping forced oscillation test. Rotary balance testing allows for the calculation of aircraft rotary derivatives and the prediction of steady-state spins. The rotary balance wind tunnel test was conducted in the NASA Langley Research Center (LaRC) 20-Foot Vertical Spin Tunnel (VST). Rotary balance testing includes runs for a set of given angular rotation rates at a range of angles of attack and sideslip angles in order to fully characterize the aircraft rotary dynamics. Tests were performed at angles of attack from 0 to 50 degrees, sideslip angles of -5 to 10 degrees, and non-dimensional spin rates from -0.5 to 0.5. The effects of pro-spin elevator and rudder deflection and pro- and anti-spin elevator, rudder, and aileron deflection were examined. The data are presented to illustrate the functional dependence of the forces and moments on angle of attack, sideslip angle, and angular rate for the rotary contributions to the forces and moments. Further investigation is necessary to fully characterize the control effectors. The data were also used with a steady state spin prediction tool that did not predict an equilibrium spin mode.
Ercoli, Carlo; Rotella, Mario; Funkenbusch, Paul D; Russell, Scott; Feng, Changyong
2009-05-01
The cutting behavior of dental rotary cutting instruments is influenced by the handpiece used. While the turbine handpiece has been extensively tested in previous studies, limited published information exists on the use of rotary cutting instruments with the electric handpiece system and on possible interactions between rotary cutting instruments and handpiece type. The purpose of this study was to examine the cutting performance of a wide selection of rotary cutting instruments tested with the electric handpiece and compare the results with those of the air-turbine handpiece (Part I), identifying possible interactions between handpiece type and rotary cutting instruments. Ten groups of rotary cutting instruments (n=30) designed for tooth preparation were selected: 9 diamond (7 multi-use, 2 disposable) and 1 carbide. Macor blocks (n=75) were used as a substrate, and 4 cuts were made on each specimen, using a new rotary cutting instrument each time, for a total of 300 cuts. The cuts were performed with an electric handpiece (Intramatic Lux K200), with the same methods used in the Part I study. To qualitatively evaluate the rotary cutting instrument surface characteristics, 1 specimen from each group was examined 3 times with a scanning electron microscope (SEM): before use, then after use, but before being cleaned and sterilized, and finally, after ultrasonic cleaning. To compare rotary cutting instrument performance between the turbine and electric handpieces, the data were analyzed using 2-way ANOVA to study the main effects of the group of rotary cutting instruments, handpieces, and their interaction. For analysis of the significant main effect, 1-way ANOVA and Tukey's Studentized Range test were used (alpha=.05). Compared to the baseline temperature, all rotary cutting instruments showed a reduction of the temperature in the simulated pulp chamber when tested with the electric handpiece. The Great White Ultra (carbide bur) showed the highest rate of advancement (0.17 mm/s) and lowest applied load (108.35 g). Considering all rotary cutting instruments as a single group, the electric handpiece showed mean lower temperature (26.68 degrees C), higher rate of advancement (0.12 mm/s), and higher load (124.53 g) than the air-turbine handpiece (28.37 degrees C, 0.11 mm/s, and 121.7 g, respectively). Considering each single group of rotary cutting instruments, significant differences were found for the electric or air-turbine handpiece. The tested carbide bur showed greater cutting efficiency than the tested diamond rotary cutting instruments when used with the electric handpiece. The electric handpiece showed a higher cutting efficiency than the turbine, especially when used with the carbide bur, probably due to its greater torque.
Ercoli, Carlo; Rotella, Mario; Funkenbusch, Paul D; Russell, Scott; Feng, Changyong
2009-04-01
Standards to test the cutting efficiency of dental rotary cutting instruments are either nonexistent or inappropriate, and knowledge of the factors that affect their cutting performance is limited. Therefore, rotary cutting instruments for crown preparation are generally marketed with weak or unsupported claims of superior performance. The purpose of this study was to examine the cutting behavior of a wide selection of rotary cutting instruments under carefully controlled and reproducible conditions with an air-turbine handpiece. Ten groups of rotary cutting instruments (n=30) designed for tooth preparation were selected: 9 diamond rotary cutting instruments (7 multi-use, 2 disposable) and 1 carbide bur. One bur per group was imaged with a scanning electron microscope (SEM) at different magnifications. Macor blocks (n=75) were used as a substrate, and 4 cuts were made on each specimen, using a new rotary cutting instrument each time, for a total of 300 cuts. The cuts were performed with an air-turbine handpiece (Midwest Quiet Air). A computer-controlled, custom-made testing apparatus was used to monitor all sensors and control the cutting action. The data were analyzed to compare the correlation of rotary cutting instrument type, grit, amount of pressure, cutting rate, revolutions per minute (rpm), temperature, and type of handpiece, using 1-way ANOVA and Tukey's Studentized Range test (alpha=.05). Compared to the baseline temperature, all rotary cutting instruments showed a reduction of temperature in the simulated pulp chamber. The Great White Ultra (carbide bur) showed a significantly higher rate of advancement (0.15 mm/s) and lower applied load (106.46 g) and rpm (304,375.97). Tooth preparation with an adequate water flow does not cause harmful temperature changes in the pulp chamber, regardless of rotary cutting instrument type. The tested carbide bur showed greater cutting efficiency than all diamond rotary cutting instruments.
Geminiani, Alessandro; Abdel-Azim, Tamer; Ercoli, Carlo; Feng, Changyong; Meirelles, Luiz; Massironi, Domenico
2014-07-01
Rotary and nonrotary cutting instruments are used to produce specific characteristics on the axial and marginal surfaces of teeth being prepared for fixed restorations. Oscillating instruments have been suggested for tooth preparation, but no comparative surface roughness data are available. To compare the surface roughness of simulated tooth preparations produced by oscillating instruments versus rotary cutting instruments with turbine and electric handpieces. Different grit rotary cutting instruments were used to prepare Macor specimens (n=36) with 2 handpieces. The surface roughness obtained with rotary cutting instruments was compared with that produced by oscillating cutting instruments. The instruments used were as follows: coarse, then fine-grit rotary cutting instruments with a turbine (group CFT) or an electric handpiece (group CFE); coarse, then medium-grit rotary cutting instruments with a turbine (group CMT) or an electric handpiece (group CME); coarse-grit rotary cutting instruments with a turbine handpiece and oscillating instruments at a low-power (group CSL) or high-power setting (group CSH). A custom testing apparatus was used to test all instruments. The average roughness was measured for each specimen with a 3-dimensional optical surface profiler and compared with 1-way ANOVA and the Tukey honestly significant difference post hoc test for multiple comparisons (α=.05). Oscillating cutting instruments produced surface roughness values similar to those produced by similar grit rotary cutting instruments with a turbine handpiece. The electric handpiece produced smoother surfaces than the turbine regardless of rotary cutting instrument grit. Rotary cutting instruments with electric handpieces produced the smoothest surface, whereas the same instruments used with a turbine and oscillating instruments achieved similar surface roughness. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Electromechanical rotary actuator
NASA Technical Reports Server (NTRS)
Smith, S. P.; Mcmahon, W. J.
1995-01-01
An electromechanical rotary actuator has been developed as the prime mover for a liquid oxygen modulation valve on the Centaur Vehicle Rocket Engine. The rotary actuator requirements, design, test, and associated problems and their solutions are discussed in this paper.
Electromechanical rotary actuator
NASA Astrophysics Data System (ADS)
Smith, S. P.; McMahon, W. J.
1995-05-01
An electromechanical rotary actuator has been developed as the prime mover for a liquid oxygen modulation valve on the Centaur Vehicle Rocket Engine. The rotary actuator requirements, design, test, and associated problems and their solutions are discussed in this paper.
Kim, Joon-Soo; Bae, Ji-Hyeon; Yun, Mi-Jung; Huh, Jung-Bo
2017-06-01
Recently, zirconia removal diamond rotary instruments have become commercially available for efficient cutting of zirconia. However, research of cutting efficiency and the cutting characteristics of zirconia removal diamond rotary instruments is limited. The purpose of this in vitro study was to assess and compare the cutting efficiency, durability, and diamond rotary instrument wear pattern of zirconia diamond removal rotary instruments with those of conventional diamond rotary instruments. In addition, the surface characteristics of the cut zirconia were assessed. Block specimens of 3 mol% yttrium cation-doped tetragonal zirconia polycrystal were machined 10 times for 1 minute each using a high-speed handpiece with 6 types of diamond rotary instrument from 2 manufacturers at a constant force of 2 N (n=5). An electronic scale was used to measure the lost weight after each cut in order to evaluate the cutting efficiency. Field emission scanning electron microscopy was used to evaluate diamond rotary instrument wear patterns and machined zirconia block surface characteristics. Data were statistically analyzed using the Kruskal-Wallis test, followed by the Mann-Whitney U test (α=.05). Zirconia removal fine grit diamond rotary instruments showed cutting efficiency that was reduced compared with conventional fine grit diamond rotary instruments. Diamond grit fracture was the most dominant diamond rotary instrument wear pattern in all groups. All machined zirconia surfaces were primarily subjected to plastic deformation, which is evidence of ductile cutting. Zirconia blocks machined with zirconia removal fine grit diamond rotary instruments showed the least incidence of surface flaws. Although zirconia removal diamond rotary instruments did not show improved cutting efficiency compared with conventional diamond rotary instruments, the machined zirconia surface showed smoother furrows of plastic deformation and fewer surface flaws. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Note: A novel rotary actuator driven by only one piezoelectric actuator.
Huang, Hu; Fu, Lu; Zhao, Hongwei; Shi, Chengli; Ren, Luquan; Li, Jianping; Qu, Han
2013-09-01
This paper presents a novel piezo-driven rotary actuator based on the parasitic motion principle. Output performances of the rotary actuator were tested and discussed. Experiment results indicate that using only one piezoelectric actuator and simple sawtooth wave control, the rotary actuator reaches the rotation velocity of about 20,097 μrad/s when the driving voltage is 100 V and the driving frequency is 90 Hz. The actuator can rotate stably with the minimum resolution of 0.7 μrad. This paper verifies feasibility of the parasitic motion principle for applications of rotary actuators, providing new design ideas for precision piezoelectric rotary actuators.
Multifuel rotary aircraft engine
NASA Technical Reports Server (NTRS)
Jones, C.; Berkowitz, M.
1980-01-01
The broad objectives of this paper are the following: (1) to summarize the Curtiss-Wright design, development and field testing background in the area of rotary aircraft engines; (2) to briefly summarize past activity and update development work in the area of stratified charge rotary combustion engines; and (3) to discuss the development of a high-performance direct injected unthrottled stratified charge rotary combustion aircraft engine. Efficiency improvements through turbocharging are also discussed.
NASA Technical Reports Server (NTRS)
Jones, C.
1983-01-01
The broad objectives of this paper are the following: (1) to summarize the Curtiss-Wright design, development and field testing background in the area of rotary aircraft engines; (2) to briefly summarize past activity and update development work in the area of stratified charge rotary combustion engines; and (3) to discuss the development of a high-performance direct injected unthrottled stratified charge rotary combustion aircraft engine. Efficiency improvements through turbocharging are also discussed.
NASA Astrophysics Data System (ADS)
1992-06-01
A development history is presented for NASA's 1983-1991 Rotary Engine Enablement Program, emphasizing the CFD approaches to various problems that were instituted from 1987 to the end of the program. In phase I, a test rig was built to intensively clarify and characterize the stratified-charge rotary engine concept. In phase II, a high pressure, electronically controlled fuel injection system was tested. In phase III, the testing of improved fuel injectors led to the achievement of the stipulated 5 hp/cu inch specific power goal. CFD-aided design of advanced rotor-pocket shapes led to additional performance improvements.
Rotary balances: A selected, annotated bibliography
NASA Technical Reports Server (NTRS)
Tuttle, Marie H.; Kilgore, Robert A.; Sych, Karen L.
1989-01-01
This bibliography on rotary balances contains 102 entries. It is part of NASA's support of the AGARD Fluid Dynamics Panel Working Group 11 on Rotary Balances. This bibliography includes works that might be useful to anyone interested in building or using rotor balances. Emphasis is on the rotary balance rigs and testing techniques rather than the aerodynamic data. Also included are some publications of historical interest which relate to key events in the development and use of rotary balances. The arrangement is chronological by date of publication in the case of reports and by presentation in the case of papers.
[Analysis of interappointment flare-ups after root canal preparation with Mtwo NiTi rotary system].
Han, Jun-li; He, Hong; Zhu, Ya-qin
2011-08-01
To study the interappointment flare-ups after root canal preparation with Mtwo NiTi rotary system and explore the influence factors. Ninty-seven pulp cases caused by caries or invisible cracks which consisted of 37 males and 60 females,16 to 62 years old were selected and divided into 2 groups randomly. One group was treated with Mtwo NiTi rotary system while the other was treated with K file, the interappointment flare-ups after root canal preparation was compared between the 2 groups. The data were subjected to Mann-Whitney U test and X(2) test with SPSS13.0 software package. Less flare-ups occurred in the group of root canal preparation with NiTi rotary system, the difference was statistically significant (P=0.027). Root canal preparation with Mtwo NiTi rotary system could decrease the flare-ups after root canal therapy.
Samiei, Mohammad; Pakdel, Seyyed Mahdi Vahid; Rikhtegaran, Sahand; Shakoei, Sahar; Ebrahimpour, Delaram; Taghavi, Pedram
2014-08-01
This study evaluated the cleaning efficacy of a root canal system by Nd:YAG laser and rotary instruments. Sixty single-rooted human teeth were divided into four experimental groups (n=15). In the first group the teeth were prepared with a step-back technique using conventional K-files. In the second and third groups, tooth preparation was carried out using Nd:YAG laser and rotary NiTi instruments, respectively. Teeth in the fourth group were prepared by combined laser and rotary methods. The smear layer remaining on canal walls was then assessed by scanning electron microscopy in the coronal, middle, and apical portions. The comparison of smear layer removal efficacy between groups was carried out by Kruskal-Wallis and Mann-Whitney U tests. The mean grades of smear layer removal in rotary-laser, rotary, laser and step-back techniques were 1.34 ± 0.18, 2.2 ± 0.28, 1.91 ± 0.25, and 2.42 ± 0.19, respectively. On the whole, differences between rotary-laser and rotary groups, step-back, and the three other techniques (rotary, laser, and rotary-laser) were significant at p=0.034. Based on the findings of this study, the cleaning efficacy of rotary, laser, and rotary-laser techniques were better than the step-back technique and the combined laser and rotary technique was the most efficient method.
Bhagavaldas, Moushmi Chalakkarayil; Diwan, Abhinav; Kusumvalli, S; Pasha, Shiraz; Devale, Madhuri; Chava, Deepak Chowdary
2017-01-01
The aim of this in vitro study was to compare the efficacy of two retreatment rotary systems in the removal of Gutta-percha (GP) and sealer from the root canal walls with or without solvent. Forty-eight extracted human mandibular first premolars were prepared and obturated with GP and AH Plus sealer. Samples were then randomly divided into four groups. Group I was retreated with MtwoR rotary system without solvent, Group II was retreated with MtwoR rotary system with Endosolv R as the solvent, Group III with D-RaCe rotary system without solvent, and Group IV with D-RaCe rotary system and Endosolv R solvent. The cleanliness of canal walls was determined by stereomicroscope (×20) and AutoCAD software. Kruskal-Wallis test and Mann-Whitney U-test were used to compare the data. Results showed that none of the retreatment systems used in this study was able to completely remove the root canal filling material. D-RaCe with or without solvent showed significantly ( P > 0.05) less filling material at all levels compared to MtwoR with/without solvent. Within the limitation of the current study, D-RaCe rotary retreatment system is more effective in removing filling material from root canal walls when compared to MtwoR rotary retreatment system.
Quorum quenching bacteria can be used to inhibit the biofouling of reverse osmosis membranes.
Oh, Hyun-Suk; Tan, Chuan Hao; Low, Jiun Hui; Rzechowicz, Miles; Siddiqui, Muhammad Faisal; Winters, Harvey; Kjelleberg, Staffan; Fane, Anthony G; Rice, Scott A
2017-04-01
Over the last few decades, significant efforts have concentrated on mitigating biofouling in reverse osmosis (RO) systems, with a focus on non-toxic and sustainable strategies. Here, we explored the potential of applying quorum quenching (QQ) bacteria to control biofouling in a laboratory-scale RO system. For these experiments, Pantoea stewartii was used as a model biofilm forming organism because it was previously shown to be a relevant wastewater isolate that also forms biofilms in a quorum sensing (QS) dependent fashion. A recombinant Escherichia coli strain, which can produce a QQ enzyme, was first tested in batch biofilm assays and significantly reduced biofilm formation by P. stewartii. Subsequently, RO membranes were fouled with P. stewartii and the QQ bacterium was introduced into the RO system using two different strategies, direct injection and immobilization within a cartridge microfilter. When the QQ bacterial cells were directly injected into the system, N-acylhomoserine lactone signals were degraded, resulting in the reduction of biofouling. Similarly, the QQ bacteria controlled biofouling when immobilized within a microfilter placed downstream of the RO module to remove QS signals circulating in the system. These results demonstrate the proof-of-principle that QQ can be applied to control biofouling of RO membranes and may be applicable for use in full-scale plants. Copyright © 2017 Elsevier Ltd. All rights reserved.
Musale, P K; Mujawar, S A V
2014-04-01
This in vitro study aimed to evaluate the efficacy of rotary ProFile, ProTaper, Hero Shaper and K-files in shaping ability, cleaning efficacy, preparation time and instrument distortion in primary molars. Sixty extracted primary mandibular second molars were divided into four equal groups: Group I K-file, Group II ProFile, Group III ProTaper file and Group IV Hero Shaper file. The shaping ability was determined by comparing pre- and post-instrumentation CBCT scans and data analysed with SPSS program using the Chi-square test. Cleaning efficacy was evaluated by the degree of India ink removal from the canal walls under stereomicroscopy. Instrumentation times were calculated for each tooth and instrument distortion was visually checked and duly noted. The cleaning efficacy and instrumentation time were determined using ANOVA with Tukey's correction. Instrument distortion was analysed using Chi-square test. The canal taper was significantly more conical for rotary files as compared to K-files with Chi-square test (p < 0.05). Cleaning efficacy of rotary files with average scores (Groups II- 0.68, III- 0.48 and IV- 0.58) was significantly better than K-files (Group I- 0.93) (p < 0.05). Mean instrumentation time with K-file (20.7 min) was significantly higher than rotary files (Groups II 8.9, III 5.6, and IV 8.1 min) (p < 0.05). Instrument distortion was observed in Group I (4.3%), while none of the rotary files were distorted. Rotary files prepared more conical canals in primary teeth than manual instruments. Reduced preparation time with rotary files enhances patient cooperation especially in young children.
Sekar, Vadhana; Kumar, Ranjith; Nandini, Suresh; Ballal, Suma; Velmurugan, Natanasabapathy
2016-01-01
The purpose of this study was to assess the role of cross section on cyclic fatigue resistance of One Shape, Revo-S SU, and Mtwo rotary files in continuous rotation and reciprocating motion in dynamic testing model. A total of 90 new rotary One Shape, Revo-S SU, and Mtwo files (ISO size 25, taper 0.06, length 25 mm) were subjected to continuous rotation or reciprocating motion. A cyclic fatigue testing device was fabricated with 60° angle of curvature and 5 mm radius. The dynamic testing of these files was performed using an electric motor which permitted the reproduction of pecking motion. All instruments were rotated or reciprocated until fracture occurred. The time taken for each instrument to fracture was recorded. All the fractured files were analyzed under a scanning electron microscope (SEM) to detect the mode of fracture. Statistical analysis was performed using one-way ANOVA, followed by Tukey's honestly significant difference post hoc test. The time taken for instruments in reciprocating motion to fail under cyclic loading was significantly longer when compared with groups in continuous rotary motion. There was a statistically significant difference between Mtwo rotary and the other two groups in both continuous and reciprocating motion. One Shape rotary files recorded significantly longer duration to fracture resistance when compared with Revo-S SU files in both continuous and reciprocating motion. SEM observations showed that the instruments of all groups had undergone a ductile mode of fracture. Reciprocating motion improved the cyclic fatigue resistance of all tested groups.
Sekar, Vadhana; Kumar, Ranjith; Nandini, Suresh; Ballal, Suma; Velmurugan, Natanasabapathy
2016-01-01
Objective: The purpose of this study was to assess the role of cross section on cyclic fatigue resistance of One Shape, Revo-S SU, and Mtwo rotary files in continuous rotation and reciprocating motion in dynamic testing model. Materials and Methods: A total of 90 new rotary One Shape, Revo-S SU, and Mtwo files (ISO size 25, taper 0.06, length 25 mm) were subjected to continuous rotation or reciprocating motion. A cyclic fatigue testing device was fabricated with 60° angle of curvature and 5 mm radius. The dynamic testing of these files was performed using an electric motor which permitted the reproduction of pecking motion. All instruments were rotated or reciprocated until fracture occurred. The time taken for each instrument to fracture was recorded. All the fractured files were analyzed under a scanning electron microscope (SEM) to detect the mode of fracture. Statistical analysis was performed using one-way ANOVA, followed by Tukey's honestly significant difference post hoc test. Results: The time taken for instruments in reciprocating motion to fail under cyclic loading was significantly longer when compared with groups in continuous rotary motion. There was a statistically significant difference between Mtwo rotary and the other two groups in both continuous and reciprocating motion. One Shape rotary files recorded significantly longer duration to fracture resistance when compared with Revo-S SU files in both continuous and reciprocating motion. SEM observations showed that the instruments of all groups had undergone a ductile mode of fracture. Conclusion: Reciprocating motion improved the cyclic fatigue resistance of all tested groups. PMID:28042272
Jindal, Rahul; Singh, Smita; Gupta, Siddharth; Jindal, Punita
2012-01-01
The purpose of this study was to evaluate and compare the apical extrusion of debris and irrigant using various rotary instruments with crown down technique in the instrumentation of root canals. Thirty freshly extracted human permanent straight rooted mandibular premolars with minimum root curvature of 0-10 ° were divided in three groups with 10 teeth in each group. Each group was instrumented using one of the three rotary instrumentation systems: Rotary Hero shapers, Rotary ProTaper and Rotary Mtwo. One ml of sterile water was used as an irrigant after using each instrument. Debris extruded was collected in pre weighed glass vials and the extruded irrigant was measured quantitatively by Myers and Montgomery method and was later evaporated. The weight of the dry extruded debris was calculated by comparing the pre and post instrumentation weight of glass vials for each group. Statistical analysis was done by using by a Kruskal-Wallis One-way ANOVA test. Statistical analysis showed that all the rotary instruments used in this study caused apical extrusion of debris and irrigant. A Statistically significant difference was observed with Rotary ProTaper and Rotary Mtwo groups when compared with Rotary Hero shapers. But no significant difference was observed between Rotary ProTaper and Rotary Mtwo groups. After instrumentation with different rotary instruments, Hero shapers showed a less apical extrusion of debris and irrigant.
Bhagavaldas, Moushmi Chalakkarayil; Diwan, Abhinav; Kusumvalli, S.; Pasha, Shiraz; Devale, Madhuri; Chava, Deepak Chowdary
2017-01-01
Objectives: The aim of this in vitro study was to compare the efficacy of two retreatment rotary systems in the removal of Gutta-percha (GP) and sealer from the root canal walls with or without solvent. Materials and Methods: Forty-eight extracted human mandibular first premolars were prepared and obturated with GP and AH Plus sealer. Samples were then randomly divided into four groups. Group I was retreated with MtwoR rotary system without solvent, Group II was retreated with MtwoR rotary system with Endosolv R as the solvent, Group III with D-RaCe rotary system without solvent, and Group IV with D-RaCe rotary system and Endosolv R solvent. The cleanliness of canal walls was determined by stereomicroscope (×20) and AutoCAD software. Kruskal–Wallis test and Mann–Whitney U-test were used to compare the data. Results: Results showed that none of the retreatment systems used in this study was able to completely remove the root canal filling material. D-RaCe with or without solvent showed significantly (P > 0.05) less filling material at all levels compared to MtwoR with/without solvent. Conclusion: Within the limitation of the current study, D-RaCe rotary retreatment system is more effective in removing filling material from root canal walls when compared to MtwoR rotary retreatment system. PMID:28761246
Development of a natural gas stratified charge rotary engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sierens, R.; Verdonck, W.
A water model has been used to determine the positions of separate inlet ports for a natural gas, stratified charge rotary engine. The flow inside the combustion chamber (mainly during the induction period) has been registered by a film camera. From these tests the best locations of the inlet ports have been obtained, a prototype of this engine has been built by Audi NSU and tested in the laboratories of the university of Gent. The results of these tests, for different stratification configurations, are given. These results are comparable with the best results obtained by Audi NSU for a homogeneousmore » natural gas rotary engine.« less
A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India.
Patil, Thimmanagowda N; Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant
2017-05-01
The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher's-exact test and the Chi-Square test. Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with experience, the management of separated file was better.
A Survey on Nickel Titanium Rotary Instruments and their Usage Techniques by Endodontists in India
Saraf, Prahlad A; Penukonda, Raghavendra; Vanaki, Sneha S; Kamatagi, Laxmikant
2017-01-01
Introduction The preference and usage of nickel titanium rotary instruments varies from individual to individual based on their technique, experience with the rotary systems and the clinical situation. Very limited information is available to explain the adoption of changing concepts with respect to nickel titanium rotary instruments pertaining to the endodontists in India. Aim The aim of this study was to conduct a questionnaire survey to acquire the knowledge concerning different NiTi rotary instruments and their usage techniques by endodontists in India. Materials and Methods A Survey questionnaire was designed which consisted of 32 questions regarding designation, demographics, experience with rotary instruments, usage of different file systems, usage techniques, frequency of reuse, occurrence of file fracture, reasons and their management was distributed by hand in the national postgraduate convention and also disseminated via electronic medium to 400 and 600 endodontists respectively. Information was collected from each individual to gain insight into the experiences and beliefs of endodontists concerning the new endodontic technology of rotary NiTi instrumentation based on their clinical experience with the rotary systems. The questions were designed to ascertain the problems, patterns of use and to identify areas of perceived or potential concern regarding the rotary instruments and the data acquired was statistically evaluated using Fisher’s-exact test and the Chi-Square test. Results Overall 63.8% (638) endodontists responded. ProTaper was one of the most commonly used file system followed by M two and ProTaper Next. There was a significant co relation between the years of experience and the file re use frequency, preparation technique, file separation, management of file separation. Conclusion A large number of Endodontists prefer to reuse the rotary NiTi instruments. As there was an increase in the experience, the incidence of file separation reduced with increasing number of re use frequency and with experience, the management of separated file was better. PMID:28658903
NASA Technical Reports Server (NTRS)
Anusonti-Inthra, Phuriwat
2010-01-01
A novel Computational Fluid Dynamics (CFD) coupling framework using a conventional Reynolds-Averaged Navier-Stokes (BANS) solver to resolve the near-body flow field and a Particle-based Vorticity Transport Method (PVTM) to predict the evolution of the far field wake is developed, refined, and evaluated for fixed and rotary wing cases. For the rotary wing case, the RANS/PVTM modules are loosely coupled to a Computational Structural Dynamics (CSD) module that provides blade motion and vehicle trim information. The PVTM module is refined by the addition of vortex diffusion, stretching, and reorientation models as well as an efficient memory model. Results from the coupled framework are compared with several experimental data sets (a fixed-wing wind tunnel test and a rotary-wing hover test).
Preetam, C S; Chandrashekhar, M; Gunaranjan, T; Kumar, S Kishore; Miskeen Sahib, S A; Kumar, M Senthil
2016-08-01
The purpose of this study is to achieve an effective method to remove root canal filling material from the root canal system. The study, thus, aims to evaluate the efficacy of the cleaning ability of two different rotary Ni-Ti systems; ProTaper Retreatment files and RaCe System compared to hand instrumentation with Hedstrom files for the removal of gutta-percha during retreatment. Thirty mandibular premolars with one single straight canal were decoronated and instrumented with ProTaper files and filled with thermoplastic gutta-percha. After 30 days, the samples were divided into three groups and gutta-percha was removed with the test instruments. The postoperative radiographs were evaluated with known criteria by dividing the root into cervical third, middle third, and apical third. The results were tabulated and Statistical Package for Social Sciences Software (IBM Corporation) was used for analysis. The mean deviation of the results were first calculated and then t-test and analysis of variance test (two-tailed P value) were evaluated for establishing significant differences. The rotary instruments were effective in removing the gutta-percha from the canals. Therefore, significant difference was observed between the efficacies of the two rotary systems used. The rotary instruments showed effective gutta-percha removal in the cervical and middle one third. (P > 0.05). However, apical debridement was effective with Hedstrom files. The study concluded the use of both rotary and hand instrumentation for effective removal of gutta-percha for retreatment.
Development of a rotary power transformer and inverter drive for spacecraft
NASA Technical Reports Server (NTRS)
Mclyman, W. T.; Bridgeforth, A. O.
1983-01-01
Many future satellites and spacecraft with spun and despun configurations will require the transfer of power across rotating interfaces in lieu of slip-rings and/or flexures. This is particularly true of spacecraft that have to demonstrate a long life expectancy. The rotary transformer has the desirable characteristics of high reliability and low noise, which qualify it as a potential replacement for slip rings. Development of a rotary power transformer follows the successful completion of a task to develop rotary signal-level transformers for the Galileo Spacecraft Project. The physical configuration of a rotary power transformer has a significant effect on its magnetic and electrical characteristics and therefore impacts the design of the dc/ac inverter driver. Important characteristics addressed during this development effort include: operating frequency, efficiency, transformer gap size, leakage inductance, and leakage flux. A breadboard inverter and rotary transformer were designed, fabricated and tested.
Patel, Dishant; Bashetty, Kusum; Srirekha, A; Archana, S; Savitha, B; Vijay, R
2016-01-01
The aim of this study was to evaluate the influence of manual versus mechanical glide path (GP) on the surface changes of two different nickel-titanium rotary instruments used during root canal therapy in a moderately curved root canal. Sixty systemically healthy controls were selected for the study. Controls were divided randomly into four groups: Group 1: Manual GP followed by RaCe rotary instruments, Group 2: Manual GP followed by HyFlex rotary instruments, Group 3: Mechanical GP followed by RaCe rotary instruments, Group 4: Mechanical GP followed by HyFlex rotary instruments. After access opening, GP was prepared and rotary instruments were used according to manufacturer's instructions. All instruments were evaluated for defects under standard error mean before their use and after a single use. The scorings for the files were given at apical and middle third. Chi-squared test was used. The results showed that there is no statistical difference between any of the groups. Irrespective of the GP and rotary files used, more defects were present in the apical third when compared to middle third of the rotary instrument. Within the limitations of this study, it can be concluded that there was no effect of manual or mechanical GP on surface defects of subsequent rotary file system used.
Bolton, Glen R; Apostolidis, Alex J
2017-09-01
Fed-batch and perfusion cell culture processes used to produce therapeutic proteins can use microfilters for product harvest. In this study, new explicit mathematical models of sieving loss due to internal membrane fouling, external membrane fouling, or a combination of the two were generated. The models accounted for membrane and cake structures and hindered solute transport. Internal membrane fouling was assumed to occur due to the accumulation of foulant on either membrane pore walls (pore-retention model) or membrane fibers (fiber-retention model). External cake fouling was assumed to occur either by the growth of a single incompressible cake layer (cake-growth) or by the accumulation of a number of independent cake layers (cake-series). The pore-retention model was combined with either the cake-series or cake-growth models to obtain models that describe internal and external fouling occurring either simultaneously or sequentially. The models were tested using well-documented sieving decline data available in the literature. The sequential pore-retention followed by cake-growth model provided a good fit of sieving decline data during beer microfiltration. The cake-series and cake-growth models provided good fits of sieving decline data during the microfiltration of a perfusion cell culture. The new models provide insights into the mechanisms of fouling that result in the loss of product sieving. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:1323-1333, 2017. © 2017 American Institute of Chemical Engineers.
Pereira, Gabriel Kalil Rocha; Lançanova, Mateus; Wandscher, Vinicius Felipe; Kaizer, Osvaldo Bazzan; Limberger, Inácio; Özcan, Mutlu; Valandro, Luiz Felipe
2015-08-01
Several rotary instruments have been daily employed on clinic to promote cut aiming to adjust the length of fiber posts to the radicular conduct, but there is no information on the literature about the effects of the different rotary instruments and its impact on the micromorphology of surface and mechanical properties of the glass fiber post. This study aimed the impact of rotary instruments upon fiber-matrix integrity, micromorphology and flexural-strength of glass-fiber posts (GFP). GFP (N=110) were divided into 5 groups: Ctrl: as-received posts, DBc: coarse diamond-bur, DBff: extra-fine diamond-bur, CB: carbide-bur, DD: diamond-disc. Cutting procedures were performed under abundant irrigation. Posts exposed to rotary instruments were then subjected to 2-point inclined loading test (compression 45°) (n=10/group) and 3-point flexural-strength test (n=10/group). Fiber-matrix integrity and micromorphology at the cut surface were analyzed using a SEM (n=2/group). Cutting procedures did not significantly affect the 2-point (51.7±4.3-56.7±5.1 MPa) (p=0.0233) and 3-point flexural-strength (671.5±35.3-709.1±33.1 MPa) (p=0.0968) of the posts (One-way ANOVA and Tukey׳s test). Fiber detachment was observed only at the end point of the cut at the margins of the post. Cut surfaces of the CB group were smoother than those of the other groups. After 3-point flexural strength test, fiber-matrix separation was evident at the tensile side of the post. Rotary instruments tested with simultaneous water-cooling did not affect the resistance of the tested fiber posts but caused disintegration of the fibers from the matrix at the end of the cut, located at the margins. Copyright © 2015 Elsevier Ltd. All rights reserved.
Rotary acceleration of a subject inhibits choice reaction time to motion in peripheral vision
NASA Technical Reports Server (NTRS)
Borkenhagen, J. M.
1974-01-01
Twelve pilots were tested in a rotation device with visual simulation, alone and in combination with rotary stimulation, in experiments with variable levels of acceleration and variable viewing angles, in a study of the effect of S's rotary acceleration on the choice reaction time for an accelerating target in peripheral vision. The pilots responded to the direction of the visual motion by moving a hand controller to the right or left. Visual-plus-rotary stimulation required a longer choice reaction time, which was inversely related to the level of acceleration and directly proportional to the viewing angle.
Results from Testing of Two Rotary Percussive Drilling Systems
NASA Technical Reports Server (NTRS)
Kriechbaum, Kristopher; Brown, Kyle; Cady, Ian; von der Heydt, Max; Klein, Kerry; Kulczycki, Eric; Okon, Avi
2010-01-01
The developmental test program for the MSL (Mars Science Laboratory) rotary percussive drill examined the e ect of various drill input parameters on the drill pene- tration rate. Some of the input parameters tested were drill angle with respect to gravity and percussive impact energy. The suite of rocks tested ranged from a high strength basalt to soft Kaolinite clay. We developed a hole start routine to reduce high sideloads from bit walk. The ongoing development test program for the IMSAH (Integrated Mars Sample Acquisition and Handling) rotary percussive corer uses many of the same rocks as the MSL suite. An additional performance parameter is core integrity. The MSL development test drill and the IMSAH test drill use similar hardware to provide rotation and percussion. However, the MSL test drill uses external stabilizers, while the IMSAH test drill does not have external stabilization. In addition the IMSAH drill is a core drill, while the MSL drill uses a solid powdering bit. Results from the testing of these two related drilling systems is examined.
Jeevanandan, Ganesh; Thomas, Eapen
2018-01-01
This present study was conducted to analyze the volumetric change in the root canal space and instrumentation time between hand files, hand files in reciprocating motion, and three rotary files in primary molars. One hundred primary mandibular molars were randomly allotted to one of the five groups. Instrumentation was done using Group I; nickel-titanium (Ni-Ti) hand file, Group II; Ni-Ti hand files in reciprocating motion, Group III; Race rotary files, Group IV; prodesign pediatric rotary files, and Group V; ProTaper rotary files. The mean volumetric changes were assessed using pre- and post-operative spiral computed tomography scans. Instrumentation time was recorded. Statistical analysis to access intergroup comparison for mean canal volume and instrumentation time was done using Bonferroni-adjusted Mann-Whitney test and Mann-Whitney test, respectively. Intergroup comparison of mean canal volume showed statistically significant difference between Groups II versus IV, Groups III versus V, and Groups IV versus V. Intergroup comparison of mean instrumentation time showed statistically significant difference among all the groups except Groups IV versus V. Among the various instrumentation techniques available, rotary instrumentation is the considered to be the better instrumentation technique for canal preparation in primary teeth.
A five week series of pilot-scale incineration tests, using a synthetic waste feed, was performed at the Environmental Protection Agency's Incineration Research Facility to evaluate the fate of trace metals fed to a rotary kiln incinerator. Eight tests studied the fate of five ha...
Dental Diamond Rotary Instruments. Test and Evaluation
1983-09-01
Gov’t. agencies only; Critical Technology; Test and Evaluation; 19 NOV 1982. Other requests shall be referred to Dental Investigation Service, School of... DENTAL DIAMOND ROTARY INSTRUMENTS Test and Evaluation Cad D. Foster, Major, USAF, DC Joseph M. Powell, Colonel, USAF, DC John M. Young, Colonel, USAF...19 November 1982. Other requests for this document must be referred to the Dental Investig tion Service, USAF School of Aerospace Medicine. SUBJECT TO
Patel, Dishant; Bashetty, Kusum; Srirekha, A.; Archana, S.; Savitha, B.; Vijay, R.
2016-01-01
Aim: The aim of this study was to evaluate the influence of manual versus mechanical glide path (GP) on the surface changes of two different nickel-titanium rotary instruments used during root canal therapy in a moderately curved root canal. Materials and Methods: Sixty systemically healthy controls were selected for the study. Controls were divided randomly into four groups: Group 1: Manual GP followed by RaCe rotary instruments, Group 2: Manual GP followed by HyFlex rotary instruments, Group 3: Mechanical GP followed by RaCe rotary instruments, Group 4: Mechanical GP followed by HyFlex rotary instruments. After access opening, GP was prepared and rotary instruments were used according to manufacturer's instructions. All instruments were evaluated for defects under standard error mean before their use and after a single use. The scorings for the files were given at apical and middle third. Statistical Analysis Used: Chi-squared test was used. Results: The results showed that there is no statistical difference between any of the groups. Irrespective of the GP and rotary files used, more defects were present in the apical third when compared to middle third of the rotary instrument. Conclusion: Within the limitations of this study, it can be concluded that there was no effect of manual or mechanical GP on surface defects of subsequent rotary file system used. PMID:27994317
Preetam, C. S.; Chandrashekhar, M.; Gunaranjan, T.; Kumar, S. Kishore; Miskeen Sahib, S. A.; Kumar, M. Senthil
2016-01-01
Aim: The purpose of this study is to achieve an effective method to remove root canal filling material from the root canal system. The study, thus, aims to evaluate the efficacy of the cleaning ability of two different rotary Ni-Ti systems; ProTaper Retreatment files and RaCe System compared to hand instrumentation with Hedstrom files for the removal of gutta-percha during retreatment. Materials and Methods: Thirty mandibular premolars with one single straight canal were decoronated and instrumented with ProTaper files and filled with thermoplastic gutta-percha. After 30 days, the samples were divided into three groups and gutta-percha was removed with the test instruments. The postoperative radiographs were evaluated with known criteria by dividing the root into cervical third, middle third, and apical third. The results were tabulated and Statistical Package for Social Sciences Software (IBM Corporation) was used for analysis. Results: The mean deviation of the results were first calculated and then t-test and analysis of variance test (two-tailed P value) were evaluated for establishing significant differences. The rotary instruments were effective in removing the gutta-percha from the canals. Therefore, significant difference was observed between the efficacies of the two rotary systems used. The rotary instruments showed effective gutta-percha removal in the cervical and middle one third. (P > 0.05). However, apical debridement was effective with Hedstrom files. Conclusion: The study concluded the use of both rotary and hand instrumentation for effective removal of gutta-percha for retreatment. PMID:27652245
Kalra, Pinky; Rao, Arathi; Suman, Ethel; Shenoy, Ramya; Suprabha, Baranya-Shrikrishna
2017-02-01
Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. Experimental single blinded randomized type of in vitro study with sample of 30 single rooted teeth. Endodontic access cavities were prepared and the root canals were filled with the suspension of E. faecalis . Myers and Montogomery Model was used to collect apically extruded debris and irrigant. Canals were prepared using K files, Hand protapers and Protaper rotary files. Non Parametric test like Kruskal-Wallis and Mann-Whitney U test were applied to determine the significant differences among the group. Tests revealed statistically significant difference between the amount of debris and number of bacteria extruded by the ProTaper hand and the K-files. No statistically significant difference was observed between the amounts of irrigant extruded by the ProTaper hand and the K-file system. Statistically significant differences were observed between the amounts of bacteria and irrigant extruded by the ProTaper rotary and the Protaper hand. No statistically significant difference was observed between the amounts of debris extruded by the ProTaper hand and the K-file system. Amount of apical extrusion of irrigant solution, bacteria and debris are significantly greater with K File instruments and least with Protaper rotary instruments. Key words: Protaper, rotary, periapical extrusion.
Small Column Ion Exchange Design and Safety Strategy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huff, T.; Rios-Armstrong, M.; Edwards, R.
2011-02-07
Small Column Ion Exchange (SCIX) is a transformational technology originally developed by the Department of Energy (DOE) Environmental Management (EM-30) office and is now being deployed at the Savannah River Site (SRS) to significantly increase overall salt processing capacity and accelerate the Liquid Waste System life-cycle. The process combines strontium and actinide removal using Monosodium Titanate (MST), Rotary Microfiltration, and cesium removal using Crystalline Silicotitanate (CST, specifically UOP IONSIV{reg_sign}IE-911 ion exchanger) to create a low level waste stream to be disposed in grout and a high level waste stream to be vitrified. The process also includes preparation of the streamsmore » for disposal, e.g., grinding of the loaded CST material. These waste processing components are technically mature and flowsheet integration studies are being performed including glass formulations studies, application specific thermal modeling, and mixing studies. The deployment program includes design and fabrication of the Rotary Microfilter (RMF) assembly, ion-exchange columns (IXCs), and grinder module, utilizing an integrated system safety design approach. The design concept is to install the process inside an existing waste tank, Tank 41H. The process consists of a feed pump with a set of four RMFs, two IXCs, a media grinder, three Submersible Mixer Pumps (SMPs), and all supporting infrastructure including media receipt and preparation facilities. The design addresses MST mixing to achieve the required strontium and actinide removal and to prevent future retrieval problems. CST achieves very high cesium loadings (up to 1,100 curies per gallon (Ci/gal) bed volume). The design addresses the hazards associated with this material including heat management (in column and in-tank), as detailed in the thermal modeling. The CST must be size reduced for compatibility with downstream processes. The design addresses material transport into and out of the grinder and includes provisions for equipment maintenance including remote handling. The design includes a robust set of nuclear safety controls compliant with DOE Standard (STD)-1189, Integration of Safety into the Design Process. The controls cover explosions, spills, boiling, aerosolization, and criticality. Natural Phenomena Hazards (NPH) including seismic event, tornado/high wind, and wildland fire are considered. In addition, the SCIX process equipment was evaluated for impact to existing facility safety equipment including the waste tank itself. SCIX is an innovative program which leverages DOE's technology development capabilities to provide a basis for a successful field deployment.« less
Logani, Ajay; Shah, Naseem
2008-01-01
To comparatively evaluate the amount of apically extruded debris when ProTaper hand, ProTaper rotary and ProFile systems were used for the instrumentation of root canals. Thirty minimally curved, mature, human mandibular premolars with single canals were randomly divided into three groups of ten teeth each. Each group was instrumented using one of the three instrumentation systems: ProTaper hand, ProTaper rotary and ProFile. Five milliliters of sterile water were used as an irrigant. Debris extruded was collected in preweighed polyethylene vials and the extruded irrigant was evaporated. The weight of the dry extruded debris was established by comparing the pre- and postinstrumentation weight of polyethylene vials for each group. The Kruskal-Wallis nonparametric test and Mann-Whitney U test were applied to determine if significant differences existed among the groups ( P< 0.05). All instruments tested produced a measurable amount of debris. No statistically significant difference was observed between ProTaper hand and ProFile system ( P > 0.05). Although ProTaper rotary extruded a relatively higher amount of debris, no statistically significant difference was observed between this type and the ProTaper hand instruments ( P > 0.05). The ProTaper rotary extruded significantly more amount of debris compared to the ProFile system ( P< 0.05). Within the limitations of this study, it can be concluded that all instruments tested produced apical extrusion of debris. The ProTaper rotary extruded a significantly higher amount of debris than the ProFile.
High pressure rotary piston coal feeder
NASA Technical Reports Server (NTRS)
Gardner, J. F.; Gencsoy, H. T.; Strimbeck, D. C.
1977-01-01
This feeder concept uniquely combines the functions of solids feeding, metering, and pressurization into one compact system. Success with the rotary-piston concept would provide a lower-cost alternative to lock-hopper systems. The design of the feeder is presented, with special emphasis on the difficult problem of seal design. Initial tests will be to check seal performance. Subsequent tests will evaluate solids-feeding ability.
Passanha, Pearl; Esteves, Sandra R; Kedia, Gopal; Dinsdale, Richard M; Guwy, Alan J
2013-11-01
The production of polyhydroxyalkanoates (PHAs) using digestate liquor as culture media is a novel application to extend the existing uses of digestates. In this study, two micro-filtered digestates (0.22 μm) were evaluated as a source of complex culture media for the production of PHA by Cupriavidus necator as compared to a conventional media. Culture media using a mixture of micro-filtered liquors from food waste and from wheat feed digesters showed a maximum PHA accumulation of 12.29 g/l PHA, with 90% cell dry weight and a yield of 0.48 g PHA/g VFA consumed, the highest reported to date for C. necator studies. From the analysis of the starting and residual media, it was concluded that ammonia, potassium, magnesium, sulfate and phosphate provided in the digestate liquors were vital for the initial growth of C. necator whereas copper, iron and nickel may have played a significant role in PHA accumulation. Copyright © 2013 Elsevier Ltd. All rights reserved.
Preliminary design development of 100 KW rotary power transfer device
NASA Technical Reports Server (NTRS)
Weinberger, S. M.
1981-01-01
Contactless power transfer devices for transferring electrical power across a rotating spacecraft interface were studied. A power level of 100 KW was of primary interest and the study was limited to alternating current devices. Rotary transformers and rotary capacitors together with the required dc to ac power conditioning electronics were examined. Microwave devices were addressed. The rotary transformer with resonant circuit power conditioning was selected as the most feasible approach. The rotary capacitor would be larger while microwave devices would be less efficient. A design analysis was made of a 100 KW, 20 kHz power transfer device consisting of a rotary transformer, power conditioning electronics, drive mechanism and heat rejection system. The size, weight and efficiency of the device were determined. The characteristics of a baseline slip ring were presented. Aspects of testing the 100 KW power transfer device were examined. The power transfer device is a feasible concept which can be implemented using presently available technologies.
Prasanthi, Nalam NVD; Rambabu, Tanikonda; Sajjan, Girija S; Varma, K Madhu; Satish, R Kalyan; Padmaja, M
2016-01-01
Aim: The aim of this study was to measure the increase in root canal surface area and canal transportation after biomechanical preparation at 1, 3, and 5 mm short of the apex with three different rotary systems in both continuous rotary and reciprocating rotary motions. Materials and Methods: Sixty freshly extracted human mandibular molars with mesial root canal curvatures between 20° and 30° were included in the study. Teeth were randomly distributed into three groups (n = 20). Biomechanical preparations were done in all the mesial canals. In Group 1, instrumentation was done with ProTaper universal rotary files, Group 2, with K3XF rotary files, and Group 3, with LSX rotary files. Each group was further subdivided into subgroups A and B (n = 10) where instrumentation was done by continuous rotary and reciprocating rotary techniques, respectively. Increase in root canal surface area and canal transportation was measured using the preoperative and postoperative cone-beam computed tomography scans. Statistical Analysis: The data were analyzed by one-way ANOVA followed by Tukey pairwise multiple comparison tests. Results: Increase in root canal surface area was significantly more (P < 0.05) in ProTaper and K3XF groups when compared to LSX group. Canal transportation was significantly more (P < 0.05) in ProTaper group when compared to K3XF and LSX groups. There was no significant difference (P > 0.05) in increase of root canal surface area and canal transportation between continuous rotary and reciprocating rotary techniques for ProTaper Universal, K3XF and LSX groups. Conclusion: LSX rotary system showed minimal increase of root canal surface area and minimal canal transportation when compared to ProTaper and K3XF rotary systems. PMID:27656062
Testing and Development of a Percussive Augmenter for Rotary Drills
NASA Technical Reports Server (NTRS)
Donnelly, Christopher; Bar-Cohen, Yoseph; Chang, Zensheu; Badescu, Mircea; Sherrit, Stewart
2011-01-01
Hammering drills are effective in fracturing the drilled medium while rotary drills remove cuttings. The combination provides a highly effective penetration mechanism. Piezoelectric actuators were integrated into an adapter to produce ultrasonic percussion; augmenting rotary drilling. The drill is capable of operating at low power, low applied force and, with proper tuning, low noise. These characteristics are of great interest for future NASA missions and the construction/remodeling industry. The developed augmenter connects a commercially available drill and bit and was tested to demonstrate its capability. Input power to the drill was read using a multimeter and the augmenter received a separate input voltage. The drive frequency of the piezoelectric actuator was controlled by a hill climb algorithm that optimizes and records average power usage to operate the drill at resonating frequency. Testing the rotary drill and augmenter across a range of combinations with total power constant at 160 Watts has shown results in concrete and limestone samples that are as good as or better than the commercial drill. The drill rate was increased 1.5 to over 10 times when compared to rotation alone.
Analysis and test of insulated components for rotary engine
NASA Technical Reports Server (NTRS)
Badgley, Patrick R.; Doup, Douglas; Kamo, Roy
1989-01-01
The direct-injection stratified-charge (DISC) rotary engine, while attractive for aviation applications due to its light weight, multifuel capability, and potentially low fuel consumption, has until now required a bulky and heavy liquid-cooling system. NASA-Lewis has undertaken the development of a cooling system-obviating, thermodynamically superior adiabatic rotary engine employing state-of-the-art thermal barrier coatings to thermally insulate engine components. The thermal barrier coating material for the cast aluminum, stainless steel, and ductile cast iron components was plasma-sprayed zirconia. DISC engine tests indicate effective thermal barrier-based heat loss reduction, but call for superior coefficient-of-thermal-expansion matching of materials and better tribological properties in the coatings used.
Zulewska, Justyna; Barbano, David M
2014-05-01
Raw milk (about 500 kg) was cold (4°C) separated and then the skim milk was pasteurized at 72°C and a holding time of 16s. The milk was cooled to 4°C and stored at ≤ 4°C until processing. The skim milk was microfiltered using a pilot-scale ceramic graded permeability (GP) microfilter system equipped with 0.1-µm nominal pore diameter ceramic Membralox membranes. First, about 155 kg of pasteurized skim milk was flushed through the system to push the water out of the system. Then, additional pasteurized skim milk (about 320 kg) was microfiltered (stage 1) in a continuous feed-and-bleed 3× process using the same membranes. The retentate from stage 1 was diluted with pasteurized reverse osmosis water in a 1:2 ratio and microfiltered (stage 2) with a GP system. This was repeated 3 times, with total of 3 stages in the process (stage 1 = microfiltration; stages 2 and 3 = diafiltration). The results from first 3 stages of the experiment were compared with previous data when processing skim milk at 50°C using ceramic uniform transmembrane pressure (UTP) membranes. Microfiltration of skim milk using ceramic UTP and GP membranes resulted in similar final retentate in terms of serum proteins (SP) removed. The SP removal rate (expressed by kilogram of SP removed per meter-squared of membrane area) was higher for GP membranes for each stage compared with UTP membranes. A higher passage of SP and SP removal rate for GP than UTP membranes was achieved by using a higher cross-flow velocity when processing skim milk. Increasing flux in subsequent stages did not affect membrane permeability and fouling. We operated under conditions that produced partial membrane fouling, due to using a flux that was less than limiting flux but higher than critical flux. Because the critical flux is a function of the cross-flow velocity, the difference in critical flux between UTP and GP membranes resulted only from operating under different cross-flow velocities (6.6 vs 7.12 for UTP and GP membranes, respectively). Conditions that allow microfiltration operation at higher flux will reduce the membrane surface area required to process the same amount of milk in the same length of time. Less membrane surface area reduces investment costs and uses less energy, water, and chemicals to clean the microfiltration system. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Rotary Engine Friction Test Rig Development Report
2011-12-01
fundamental research is needed to understand the friction characteristics of the rotary engine that lead to accelerated wear and tear on the seals...that includes a turbocharger . Once the original GT-Suite model is validated, the turbocharger model will be more accurate. This validation will...prepare for turbocharger and fuel-injector testing, which will lead to further development and calibration of the model. Further details are beyond the
NASA Technical Reports Server (NTRS)
Nguyen, H. L.; Addy, H. E.; Bond, T. H.; Lee, C. M.; Chun, K. S.
1987-01-01
A computer simulation which models engine performance of the Direct Injection Stratified Charge (DISC) rotary engines was used to study the effect of variations in engine design and operating parameters on engine performance and efficiency of an Outboard Marine Corporation (OMC) experimental rotary combustion engine. Engine pressure data were used in a heat release analysis to study the effects of heat transfer, leakage, and crevice flows. Predicted engine data were compared with experimental test data over a range of engine speeds and loads. An examination of methods to improve the performance of the rotary engine using advanced heat engine concepts such as faster combustion, reduced leakage, and turbocharging is also presented.
1990-01-01
critical examination of the rotary-balance techniques used in the AGARD community for the analysis of high-angle-of-attack dynamic behavior of aircraft. It...aircraft. It was felt that sudi a critical examination should encompass both the experimental techniques used to obtain rotary-flow aerodynamic data and the...monitor the vibrational and critical structural characteristies of the apparatus and tunnel support system. Many of these systems are integrated directly
Inan, Ugur; Aydin, Cumhur
2012-01-01
A number of rotary nickel-titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system, and recently, rotary NiTi systems designed for root canal retreatment have been introduced. Because the main problem with the rotary NiTi files is fracture, the aim of this study was to compare the cyclic fatigue resistance of 3 different rotary NiTi systems designed for root canal retreatment. Total of 60 instruments of 3 different rotary NiTi systems designed for root canal retreatment were used in this study. Twenty R-Endo R3, 20 ProTaper D3, and 20 Mtwo R (Retreatment) 25.05 instruments were tested. Cyclic fatigue testing of instruments was performed by using a device that allowed the instruments to rotate freely inside an artificial canal. Each instrument was rotated until fracture occurred, and the number of cycles to fracture for each instrument was calculated. Representative samples were also evaluated under a scanning electron microscope to confirm the fracture was flexural. Data were analyzed by using 1-way analysis of variance test. R-Endo R3 instruments showed better cyclic fatigue resistance than ProTaper D3 and Mtwo R 25.05 instruments, and the difference was statistically significant (P < .05). There was no significant difference between ProTaper D3 and Mtwo R 25.05 groups. The R-Endo R3 instruments were more resistant to fatigue failure than ProTaper D3 and Mtwo R 25.05. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Kalra, Pinky; Suman, Ethel; Shenoy, Ramya; Suprabha, Baranya-Shrikrishna
2017-01-01
Background Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. Aim The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. Design Experimental single blinded randomized type of in vitro study with sample of 30 single rooted teeth. Endodontic access cavities were prepared and the root canals were filled with the suspension of E. faecalis. Myers and Montogomery Model was used to collect apically extruded debris and irrigant. Canals were prepared using K files, Hand protapers and Protaper rotary files. Statistical analysis Non Parametric test like Kruskal-Wallis and Mann-Whitney U test were applied to determine the significant differences among the group. Results Tests revealed statistically significant difference between the amount of debris and number of bacteria extruded by the ProTaper hand and the K-files. No statistically significant difference was observed between the amounts of irrigant extruded by the ProTaper hand and the K-file system. Statistically significant differences were observed between the amounts of bacteria and irrigant extruded by the ProTaper rotary and the Protaper hand. No statistically significant difference was observed between the amounts of debris extruded by the ProTaper hand and the K-file system. Conclusions Amount of apical extrusion of irrigant solution, bacteria and debris are significantly greater with K File instruments and least with Protaper rotary instruments. Key words:Protaper, rotary, periapical extrusion. PMID:28210445
Valois, Caroline R A; Silva, Luciano P; Azevedo, Ricardo B
2008-07-01
The purpose of this study was to evaluate the surface of rotary nickel-titanium (Ni-Ti) files after multiple autoclave cycles. Two different types of rotary Ni-Ti (Greater Taper and ProFile) were attached to a glass base. After 1, 5, and 10 autoclave cycles the files were positioned in the atomic force microscope. The analyses were performed on 15 different points. The same files were used as control before any autoclave cycle. The following vertical topographic parameters were measured: arithmetic mean roughness, maximum height, and root mean square. The differences were tested by analysis of variance with Tukey test. All topographic parameters were higher for both Greater Taper and ProFile after 10 cycles compared with the control (P < .05). ProFile also showed higher topographic parameters after 5 cycles compared with the control (P < .05). The results indicated that multiple autoclave cycles increase the depth of surface irregularities located on rotary Ni-Ti files.
Manipulator having thermally conductive rotary joint for transferring heat from a test specimen
Haney, Steven J.; Stulen, Richard H.; Toly, Norman F.
1985-01-01
A manipulator for rotatably moving a test specimen in an ultra-high vacuum chamber includes a translational unit movable in three mutually perpendicular directions. A manipulator frame is rigidly secured to the translational unit for rotatably supporting a rotary shaft. A first copper disc is rigidly secured to an end of the rotary shaft for rotary movement within the vacuum chamber. A second copper disc is supported upon the first disc. The second disc receives a cryogenic cold head and does not rotate with the first disc. A sapphire plate is interposed between the first and second discs to prevent galling of the copper material while maintaining high thermal conductivity between the first and second discs. A spring is disposed on the shaft to urge the second disc toward the first disc and compressingly engage the interposed sapphire plate. A specimen mount is secured to the first disc for rotation within the vacuum chamber. The specimen maintains high thermal conductivity with the second disc receiving the cryogenic transfer line.
Shahi, Shahriar; Yavari, Hamid R; Rahimi, Saeed; Reyhani, Mohammad F; Kamarroosta, Zahra; Abdolrahimi, Majid
2009-03-01
The aim of this study was to evaluate the effect of RaCe, FlexMaster and ProFile rotary instruments on smear layer formation by scanning electron microscopy. Eighty-four caries-free freshly extracted human single-rooted teeth were selected and divided into three groups, each containing 28 teeth. The teeth were instrumented with rotary instruments sequentially: Group A: ProFile Rotary Instruments; Group B: FlexMaster Rotary Instruments; and Group C: RaCe Rotary Instruments. Instrumentation was performed by the crown-down method and according to the manufacturer's instructions. The specimens were then examined with SEM according to Hülsmann's classification. One-way ANOVA and a post hoc Tukey test were used for statistical analysis. The results showed that there were no statistically significant differences among the three groups in the coronal third (P = 0.39), but at the apical and middle thirds there were statistically significant differences between the RaCe group and the other groups (P < 0.05). Smear layer in the RaCe group was less than that in the ProFile and FlexMaster groups, but the difference between the ProFile group and FlexMaster group was not statistically significant (P > 0.05). It was concluded that RaCe Rotary Instruments produce less smear layer than FlexMaster and ProFile Rotary Instruments.
Reddy, K Balakoti; Dash, Shreemoy; Kallepalli, Sowmya; Vallikanthan, Sangeetha; Chakrapani, N; Kalepu, Vamsi
2013-11-01
The present study was conducted to compare the cleaning efficacy (debris and smear layer removal) of hand and two NiTi rotary instrumentation systems (K3 and ProTaper). Sixty single rooted human maxillary anterior teeth decoronated at the cementoenamel junction were used. All the specimens were divided into four groups of 15 teeth each, group I--ProTaper rotary instrumentation done, group II--K3 rotary instrumentation done, group III--Stainless steel K-file instrumentation done, group IV--root canal irrigation without instrumentation. Root canal preparation was done in a crown down manner and 3% sodium hypochlorite was used as irrigant after each file followed by final rinse with 5 ml of 17% EDTA solution, then specimens were scanning electron microscopic (SEM) examination. Statistical analysis was done using one-way ANOVA followed by post hoc Tukey's HSD test. Group I showed highly statistical significant difference compared to other groups. There was no statistically significant difference considering smear layer at any levels among the groups with no smear layer formation in group IV. ProTaper rotary instrumentation showed the maximum cleaning efficacy followed by K3 rotary instrumentation in the coronal, middle and apical thirds of the root canal. ProTaper rotary instruments are more efficient than hand and K3 rotary instruments during root canal treatment.
Alternative Technology for Transit Bus Air Conditioning : The Rotary Screw Compressor
DOT National Transportation Integrated Search
1984-11-01
This report summarizes the results of the test and evaluation of a prototype rotary screw compressor design. The UMTA-funded R&D program consisted of two phases. The objectives of the first phase were to ascertain the extent of the problems with curr...
Rotella, Mario; Ercoli, Carlo; Funkenbusch, Paul D; Russell, Scott; Feng, Changyong
2014-01-01
As single-use rotary cutting instruments and electric handpieces become more available, the performance of these instruments with electric as compared to turbine handpieces requires evaluation. In addition, if rotary cutting instruments marketed as single-use instruments are used for multiple patients, the effects on their performance of cleaning, sterilization, and repeated use are of interest to the clinician. The purpose of the study was to evaluate how the cleaning, autoclaving, and repeated use of single-use and multiuse rotary cutting instruments, with either a turbine or electric handpiece, affected their performance. The effects on cutting performance of 2 handpieces (turbine and electric), 2 cleaning and sterilization conditions (cleaned and autoclaved versus noncleaned and nonautoclaved), and 6 different diamond rotary cutting instruments (4 single-use and 2 multiuse) during simulated tooth preparations were evaluated by using a 24-treatment condition full-factorial experimental design. A computer-controlled dedicated testing apparatus was used to simulate the cutting procedures, and machinable glass ceramic blocks were used as the cutting substrate for tangential cuts. In addition, for each treatment condition, 8 consecutive cuts, for a total of 192 cuts, were measured to assess the durability of the rotary cutting instruments. A linear mixed model was used to study the effect of instrument type, handpiece, cleaning, and sterilization, as well as the status and number of cuts on the outcome variables. The Tukey honestly significant difference test was used for the post hoc pairwise comparisons (α=.05). Performance, as measured by the rate of advancement, decreased with the repeated use of rotary cutting instruments (P<.001), while cleaning and sterilization procedures improved the average performance of the 8 cuts (P=.002). The electric handpiece showed a greater load than the turbine (P<.001) and a lower rate/load metric, but no differences in the rate of advancement. Significant differences were also detected among the different rotary cutting instruments tested with the Two Striper, which showed the highest cumulative performance of all groups. The repeated use of both single-use and multiuse rotary cutting instruments decreased cutting performance. The use of a cleaning and sterilization procedure between cuts improved the average cutting performance. During a tangential cutting process, although the ease of advancement (rate/load) was greater for the turbine, the electric handpiece did not produce a statistically different cutting rate. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Garg, Shiwani; Mahajan, Pardeep; Thaman, Deepa; Monga, Prashant
2015-01-01
To compare dentinal damage caused by hand and rotary nickel-titanium instruments using ProTaper, K3 Endo, and Easy RaCe systems after root canal preparation. One hundred and fifty freshly extracted mandibular premolars were randomly divided into five experimental groups of 30 teeth each and biomechanical preparation was done: Group 1 with unprepared teeth; Group 2 were prepared with hand files; Group 3 with ProTaper rotary instruments; Group 4 with K3 rotary; Group 5 with Easy RaCe rotary instruments. Then, roots were cut horizontally at 3, 6, and 9 mm from apex and were viewed under stereomicroscope. The presence of dentinal defects was noted. Groups were analyzed with the Chi-square test. Significant difference was seen between groups. No defects were found in unprepared roots and those prepared with hand files. ProTaper, K3 rotary, and Easy RaCe preparations resulted in dentinal defects in 23.3%, 10%, and 16.7% of teeth, respectively. More defects were shown in coronal and middle sections, and no defect was seen in apical third. The present study revealed that use of rotary instruments could result in an increased chance for dentinal defects as compared to hand instrumentation.
Comparison of near fusional vergence ranges with rotary prisms and with prism bars.
Goss, David A; Becker, Emily
2011-02-01
Common methods for determination of fusional vergence ranges make use of rotary prisms in the phoropter or prism bars out of the phoropter. This study compared near fusional vergence ranges with rotary prisms with those with prism bars. Fifty young adults served as subjects. Odd-numbered subjects had rotary prism vergences performed before prism bar vergences. For even-numbered subjects, prism bar vergences were done first. Base-in (BI) vergences were done before base-out (BO) vergences with both rotary prisms and prism bars. A coefficient of agreement was calculated by multiplying the standard deviation of the individual subject differences between rotary prisms and prism bars by 1.96, to approximate the range within which the 2 tests would agree 95% of the time. The lowest coefficient of agreement was 7.3Δ for the BI recovery. The others were high, ranging from 15.4Δ for the BO recovery to 19.5Δ for the BO break. Fusional vergence ranges determined by prism bars out of the phoropter cannot be used interchangeably with those determined by phoropter rotary prisms for the purpose of follow-up on individual patients or for the purpose of comparison with norms. Copyright © 2010 American Optometric Association. Published by Elsevier Inc. All rights reserved.
Coal desulfurization in a rotary kiln combustor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cobb, J.T. Jr.
1991-04-22
The focus of our work during the first quarter of 1991 was on combustion tests at the PEDCO rotary kiln reactor at North American Rayon (NARCO) plant in Elizabethton, TN. The tests had essentially tow related objectives: (a) to obtain basic data on the combustion of anthracite culm in a rotary kiln reactor, and (b) upon the test results, determine how best to proceed with our own planned program at the Humphrey Charcoal kiln in Brookville, PA. The rationale for the tests at PEDCO arose from process analysis which posted red flags on the feasibility of burning low-grade, hard-to-burn fuelsmore » like anthracite culms, in the rotary kiln. The PEDCO unit afforded a unique opportunity to obtain some quick answers at low cost. Two different anthracite culm fuels were tested: a so-called Jeddo culm with an average heating value of 7000 Btu/lb, and a relatively poorer culm, and Emerald'' culm, with an average heating value of 5000 Btu/lb. An attempt was also made to burn a blend of the Emerald culm with bituminous coal in 75/25 percent proportions. This report describes the tests, their chronology, and preliminary results. As it turned out, the PEDCO unit is not configured properly for the combustion of anthracite culm. As a result, it proved difficult to achieve a sustained period of steady-state combustion operation, and combustion efficiencies were low even when supplemental fuel was used to aid combustion of the culm. 1 fig., 2 tabs.« less
NASA Technical Reports Server (NTRS)
Lopez, Armando E.; Buell, Donald A.; Tinling, Bruce E.
1959-01-01
Wind-tunnel measurements were made of the static and dynamic rotary stability derivatives of an airplane model having sweptback wing and tail surfaces. The Mach number range of the tests was from 0.23 to 0.94. The components of the model were tested in various combinations so that the separate contribution to the stability derivatives of the component parts and the interference effects could be determined. Estimates of the dynamic rotary derivatives based on some of the simpler existing procedures which utilize static force data were found to be in reasonable agreement with the experimental results at low angles of attack. The results of the static and dynamic measurements were used to compute the short-period oscillatory characteristics of an airplane geometrically similar to the test model. The results of these calculations are compared with military flying qualities requirements.
A novel optical rotary encoder with eccentricity self-detection ability.
Li, Xuan; Ye, Guoyong; Liu, Hongzhong; Ban, Yaowen; Shi, Yongsheng; Yin, Lei; Lu, Bingheng
2017-11-01
Eccentricity error is the main error source of optical rotary encoders. Real-time detection and compensation of the eccentricity error is an effective way of improving the accuracy of rotary optical encoders. In this paper, a novel rotary optical encoder is presented to realize eccentricity self-detection. The proposed encoder adopts a spider-web-patterned scale grating as a measuring standard which is scanned by a dual-head scanning unit. Two scanning heads of the dual-head scanning unit, which are arranged orthogonally, have the function of scanning the periodic pattern of the scale grating along the angular and radial directions, respectively. By this means, synchronous measurement of angular and radial displacements of the scale grating is realized. This paper gives the details of the operating principle of the rotary optical encoder, developing and testing work of a prototype. The eccentricity self-detection result agrees well with the result measured by an optical microscope. The experimental result preliminarily proves the feasibility and effectiveness of the proposed optical encoder.
A novel optical rotary encoder with eccentricity self-detection ability
NASA Astrophysics Data System (ADS)
Li, Xuan; Ye, Guoyong; Liu, Hongzhong; Ban, Yaowen; Shi, Yongsheng; Yin, Lei; Lu, Bingheng
2017-11-01
Eccentricity error is the main error source of optical rotary encoders. Real-time detection and compensation of the eccentricity error is an effective way of improving the accuracy of rotary optical encoders. In this paper, a novel rotary optical encoder is presented to realize eccentricity self-detection. The proposed encoder adopts a spider-web-patterned scale grating as a measuring standard which is scanned by a dual-head scanning unit. Two scanning heads of the dual-head scanning unit, which are arranged orthogonally, have the function of scanning the periodic pattern of the scale grating along the angular and radial directions, respectively. By this means, synchronous measurement of angular and radial displacements of the scale grating is realized. This paper gives the details of the operating principle of the rotary optical encoder, developing and testing work of a prototype. The eccentricity self-detection result agrees well with the result measured by an optical microscope. The experimental result preliminarily proves the feasibility and effectiveness of the proposed optical encoder.
DOT National Transportation Integrated Search
1978-05-01
Experimental data were obtained in dynamometer tests of a 1975 Mazda 70 CID, 4V rotary engine to determine fuel consumption and emissions (hydrocarbon, carbon monoxide, oxides of nitrogen) at steady-state engine-operating modes. The objective of the ...
Manipulator having thermally conductive rotary joint for transferring heat from a test specimen
Haney, S.J.; Stulen, R.H.; Toly, N.F.
1983-05-03
A manipulator for rotatably moving a test specimen in an ultra-high vacuum chamber includes a translational unit movable in three mutually perpendicular directions. A manipulator frame is rigidly secured to the translational unit for rotatably supporting a rotary shaft. A first copper disc is rigidly secured to an end of the rotary shaft for rotary movement within the vacuum chamber. A second copper disc is supported upon the first disc. The second disc receives a cryogenic cold head and does not rotate with the first disc. The second disc receives a cryogenic cold head and does not rotate with the first disc. A sapphire plate is interposed between the first and second discs to prevent galling of the copper material while maintaining high thermal conductivity between the first and second discs. A spring is disposed on the shaft to urge the second disc toward the first disc and compressingly engage the interposed sapphire plate. A specimen mount is secured to the first disc for rotation within the vacuum chamber. The specimen maintains high thermal conductivity with the second disc receiving the cryogenic transfer line.
Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, E M G
2017-01-01
In permanent dentition, different rotary systems are used for canal cleaning and shaping. Rotary instrumentation in pediatric dentistry is an emerging concept. A very few studies have compared the efficiency of rotary instrumentation for canal preparation in primary teeth. Hence, this study was performed to compare the obturation quality and instrumentation time of two rotary files systems - Protaper, Mtwo with hand files in primary molars. Forty-five primary mandibular molars were randomly allotted to one of the three groups. Instrumentation was done using K-files in Group 1; Protaper in Group 2; and Mtwo in Group 3. Instrumentation time was recorded. The canal filling quality was assessed as underfill, optimal fill, and overfill. Statistical analysis was done using Chi-square, ANOVA, and post hoc Tukey test. No significant difference was observed in the quality of obturation among three groups. Intergroup comparison of the instrumentation time showed a statistically significant difference between the three groups. The use of rotary instrumentation in primary teeth results in marked reduction in the instrumentation time and improves the quality of obturation.
Development of natural gas rotary engines
NASA Astrophysics Data System (ADS)
Mack, J. R.
1991-08-01
Development of natural gas-fueled rotary engines was pursued on the parallel paths of converted Mazda automotive engines and of establishing technology and demonstration of a test model of a larger John Deer Technologies Incorporated (JDTI) rotary engine with power capability of 250 HP per power section for future production of multi-rotor engines with power ratings 250, 500, and 1000 HP and upward. Mazda engines were converted to natural gas and were characterized by a laboratory which was followed by nearly 12,000 hours of testing in three different field installations. To develop technology for the larger JDTI engine, laboratory and engine materials testing was accomplished. Extensive combustion analysis computer codes were modified, verified, and utilized to predict engine performance, to guide parameters for actual engine design, and to identify further improvements. A single rotor test engine of 5.8 liter displacement was designed for natural gas operation based on the JDTI 580 engine series. This engine was built and tested. It ran well and essentially achieved predicted performance. Lean combustion and low NOW emission were demonstrated.
Comparative Study of Piezoelectric and Rotary Osteotomy Technique for Third Molar Impaction.
Basheer, Sulphi A; Govind, R Jay; Daniel, Augustine; Sam, George; Adarsh, V J; Rao, Akshatha
2017-01-01
Bone removal is necessary for extracting the third molars that are erupted, partially erupted, and/or impacted in bone. Hence, it is necessary to choose a surgical method or instruments that conform to anatomic landmarks and are based on physiological principles. Many authors have reported injuries to the adjacent tooth, especially the distal part of periodontium after removal of second molar. Hence, the present study was undertaken to assess and compare the surgical and postsurgi-cal outcomes of third molar removal using piezoelectric surgery and rotary bur. A total of 30 healthy adult individuals who were in need of prophylactic removal of impacted man-dibular third molar tooth with ideal condition were included for the study. Individuals were divided randomly into study groups of 15 each, so that the difficulty of surgery will be the same in both the groups. Group I - piezoelectric osteotomy technique and group II - rotary osteotomy technique. The rotary device consists of a hand piece and a rotary speed ranging around 35,000 rpm was used. The piezoelectric device consists of a hand piece, and a frequency of 25 to 29 kHz with a microvibration of 60 to 200 mm/sec was used with a boosted working mode. Data were analyzed using unpaired t-test and qualitative data were analyzed using Fischer's exact test. The average age of the study subjects in the piezo-surgery group and rotary group was 28.40 ± 2.69 and 30.06 ± 3.15 years respectively. The time taken for removal of impacted tooth by rotary bur was less than that by piezoelectric device, which was significant statistically (p < 0.05). Until the 4th postoperative day, severity of pain experienced was more in the rotary group, which was statistically significant (p < 0.005). Mouth opening was significantly better in the piezoelectric group as compared with rotary bur until the 7th postoperative day. The piezosurgery method reduces postoperative pain, trismus, and swelling. Also, it may play an important role in increasing bone density within the extraction socket and decreasing the amount of bone loss of adjacent tooth in the distal aspect. In clinical practice, piezosurgery plays an important role because piezosurgery reduces postoperative pain, trismus, and also swelling.
Comparison between rotary and manual instrumentation in primary teeth.
Crespo, S; Cortes, O; Garcia, C; Perez, L
2008-01-01
The aim of this study was to compare the efficiency in both, preparation time and root canal shape, when using the Nickel Titanium (Ni-Ti) rotary and K-Files hand instrumentation on root canal preparation of single rooted primary teeth. Sixty single rooted primary teeth were selected and divided into two equal groups: Group (I) 30 teeth instrumented with manual K-files and group (II) 30 teeth instrumented with Ni-Ti rotary files (ProFile 0.04). Instrumentation times were calculated and root canal impressions were taken with light bodied silicone in order to evaluate the shape. The data was analyzed with SPSS program using the t-test and the Chi-square test to compare their means. The preparation time with group (I) K-files was significantly higher than in group (II) rotary files (ProFile 0.04), with a p= .005. The ProFile system showed a significantly more favorable canal taper when compared to the K-files system (P= .002). The use of rotary files in primary teeth has several advantages when compared with manual K files: the efficiency in both, preparation time and root canal shape. 1. A decreased working time, that helps maintain patient cooperation by diminishing the potential for tiredness. 2. The shape of the root canal is more conical, favoring a higher quality of the root canal filling, and increasing clinical success.
USING CERAMIC MEMBRANES TO RECYCLE TWO NONIONIC ALKALINE METAL-CLEANING SOLUTIONS
One ZrO2 ultrafilter (0.05 um pore size) and two a-Al2O3 microfilters (0.2 and 0.8 um) were used to remove one synthetic ester oil and two polyalphaolefin-based and two petroleum hydrocarbon-based oils and greases from two nonionic alkaline cleaning solutions (e.g., Turco 4215-NC...
A 5-week series of pilot-scale incineration tests, employing a synthetic waste feed, was performed at the U.S. Environmental Protection Agency's Incineration Research Facility to evaluate the fate of trace metals fed to a rotary kiln incinerator equipped with a venturi scrubber/p...
A series of pilot-scale incineration tests was performed at EPA's Incineration Research Facility (IRF) in Jefferson, Arkansas, to evaluate the fate of trace metals fed to a rotary kiln incinerator equipped with an ionizing wet scrubber (IWS) for particulate and acid gas control. ...
Flow induction by pressure forces
NASA Technical Reports Server (NTRS)
Garris, C. A.; Toh, K. H.; Amin, S.
1992-01-01
A dual experimental/computational approach to the fluid mechanics of complex interactions that take place in a rotary-jet ejector is presented. The long-range goal is to perform both detailed flow mapping and finite element computational analysis. The described work represents an initial finding on the experimental mapping program. Test results on the hubless rotary-jet are discussed.
A series of pilot-scale incineration tests was performed at EPA's Incineration Research Facility (IRF) in Jefferson, Arkansas, to evaluate the fate of trace metals fed to a rotary kiln incinerator equipped with an ionizing wet scrubber (IWS) for particulate and acid gas control. ...
Reddy, J M V Raghavendra; Latha, Prasanna; Gowda, Basavana; Manvikar, Varadendra; Vijayalaxmi, D Benal; Ponangi, Kalyana Chakravarthi
2014-02-01
Predictable successful endodontic therapy depends on correct diagnosis, effective cleaning, shaping and disinfection of the root canals and adequate obturation. Irrigation serves as a flush to remove debris, tissue solvent and lubricant from the canal irregularities; however these irregularities can restrict the complete debridement of root canal by mechanical instrumentation.Various types of hand and rotary instruments are used for the preparation of the root canal system to obtain debris free canals. The purpose of this study was to evaluate the amount of smear layer and debris removal on canal walls following the using of manual Nickel-Titanium (NiTi) files compared with rotary ProTaperNiTi files using a Scanning Electron Microscope in two individual groups. A comparative study consisting of 50 subjects randomized into two groups - 25 subjects in Group A (manual) and 25 subjects in Group B (rotary) was undertaken to investigate and compare the effects of smear layer and debris between manual and rotary NiTi instruments. Chi square test was used to find the significance of smear layer and debris removal in the coronal, middle and apical between Group A and Group B. Both systems of Rotary ProTaperNiTi and manual NiTi files used in the present study, did not create completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary ProTaperNiTi instruments. Rotary instruments were less time consuming when compared to manual instruments. Instrument separation was not found to be significant with both the groups. Both systems of Rotary ProTaperNiTi and manual NiTi files used did not produce completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary protaper instruments. How to cite the article: Reddy JM, Latha P, Gowda B, Manvikar V, Vijayalaxmi DB, Ponangi KC. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni-Ti files - An In-Vitro SEM study. J Int Oral Health 2014;6(1):89-94.
Reddy, J M V Raghavendra; Latha, Prasanna; Gowda, Basavana; Manvikar, Varadendra; Vijayalaxmi, D Benal; Ponangi, Kalyana Chakravarthi
2014-01-01
Background: Predictable successful endodontic therapy depends on correct diagnosis, effective cleaning, shaping and disinfection of the root canals and adequate obturation. Irrigation serves as a flush to remove debris, tissue solvent and lubricant from the canal irregularities; however these irregularities can restrict the complete debridement of root canal by mechanical instrumentation.Various types of hand and rotary instruments are used for the preparation of the root canal system to obtain debris free canals. The purpose of this study was to evaluate the amount of smear layer and debris removal on canal walls following the using of manual Nickel-Titanium (NiTi) files compared with rotary ProTaperNiTi files using a Scanning Electron Microscope in two individual groups. Materials & Methods: A comparative study consisting of 50 subjects randomized into two groups – 25 subjects in Group A (manual) and 25 subjects in Group B (rotary) was undertaken to investigate and compare the effects of smear layer and debris between manual and rotary NiTi instruments. Chi square test was used to find the significance of smear layer and debris removal in the coronal, middle and apical between Group A and Group B. Results: Both systems of Rotary ProTaperNiTi and manual NiTi files used in the present study, did not create completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary ProTaperNiTi instruments. Rotary instruments were less time consuming when compared to manual instruments. Instrument separation was not found to be significant with both the groups. Conclusions: Both systems of Rotary ProTaperNiTi and manual NiTi files used did not produce completely clean root canals. Manual NiTi files produced significantly less smear layer and debris compared to Rotary protaper instruments. How to cite the article: Reddy JM, Latha P, Gowda B, Manvikar V, Vijayalaxmi DB, Ponangi KC. Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni-Ti files - An In-Vitro SEM study. J Int Oral Health 2014;6(1):89-94. PMID:24653610
Kavitha, Swaminathan; Thomas, Eapen; Anadhan, Vasanthakumari; Vijayakumar, Rajendran
2016-01-01
Introduction The intention of root canal preparation is to reduce infected content and create a root canal shape allowing for a well condensed root filling. Therefore, it is not necessary to remove excessive dentine for successful root canal preparation and concern must be taken not to over instrument as perforations can occur in the thin dentinal walls of primary molars. Aim This study was done to evaluate the time preparation, the risk of lateral perforation and dentine removal of the stainless steel K file and K3 rotary instrumentation in primary teeth. Materials and Methods Seventy-five primary molars were selected and divided into three groups. Using spiral computed tomography the teeth were scanned before instrumentation. Teeth were prepared using a stainless steel K file for manual technique. All the canals were prepared up to file size 35. In K3 rotary files (.02 taper) instrumentation was done up to 35 size file. In K3 rotary files (.04 taper) the instrumentation was done up to 25 size file and simultaneously the instrumentation time was recorded. The instrumented teeth were once again scanned and the images were compared with the images of the uninstrumented canals. Statistical Analysis Data was statistically analysed using Kruskal Wallis One-way ANOVA, Mann-Whitney U-Test and Pearson’s Chi-square Test. Results K3 rotary files (.02 taper) removed a significantly less amount of dentine, required less instrumentation time than a stainless steel K file. Conclusion K3 files (.02 taper) generated less dentine removal than the stainless steel K file and K3 files (.04 taper). K3 rotary files (.02 taper) were more effective for root canal instrumentation in primary teeth. PMID:26894166
Giuliani, Valentina; Cocchetti, Roberto; Pagavino, Gabriella
2008-11-01
The aim of this study was to evaluate the efficacy of the ProTaper Universal System rotary retreatment system and of Profile 0.06 and hand instruments (K-file) in the removal of root filling materials. Forty-two extracted single-rooted anterior teeth were selected. The root canals were enlarged with nickel-titanium (NiTi) rotary files, filled with gutta-percha and sealer, and randomly divided into 3 experimental groups. The filling materials were removed with solvent in conjunction with one of the following devices and techniques: the ProTaper Universal System for retreatment, ProFile 0.06, and hand instruments (K-file). The roots were longitudinally sectioned, and the image of the root surface was photographed. The images were captured in JPEG format; the areas of the remaining filling materials and the time required for removing the gutta-percha and sealer were calculated by using the nonparametric one-way Kruskal-Wallis test and Tukey-Kramer tests, respectively. The group that showed better results for removing filling materials was the ProTaper Universal System for retreatment files, whereas the group of ProFile rotary instruments yielded better root canal cleanliness than the hand instruments, even though there was no statistically significant difference. The ProTaper Universal System for retreatment and ProFile rotary instruments worked significantly faster than the K-file. The ProTaper Universal System for retreatment files left cleaner root canal walls than the K-file hand instruments and the ProFile Rotary instruments, although none of the devices used guaranteed complete removal of the filling materials. The rotary NiTi system proved to be faster than hand instruments in removing root filling materials.
Khoshbin, Elham; Donyavi, Zakiyeh; Abbasi Atibeh, Erfan; Roshanaei, Ghodratollah; Amani, Faranak
2018-01-01
Endodontic rotary systems may result in dentinal cracks. They may propagate to vertical root fracture that compromises the outcome of endodontic treatment. This study aimed to compare Neolix and Reciproc (single-file systems), Mtwo and ProTaper (conventional rotary systems) in terms of dentinal crack formation in root canal walls. This in vitro study was conducted on 110 extracted human single-rooted teeth. The teeth were randomly divided into four experimental groups ( n =25) for root canal preparation with Neolix, Reciproc, Mtwo and ProTaper systems and two control groups ( n =5). The first control group underwent root canal instrumentation with hand files while the second control group received no preparation and was only irrigated. After instrumentation, root canals were horizontally sectioned at 3, 6 and 9 mm from the apex and inspected under a stereomicroscope under 12× magnification for detection of cracks. The data were analyzed using Chi-square, GEE test and Bonferroni tests ( P <0.05). No crack was found in the control groups. All rotary systems caused dentinal cracks. ProTaper, Reciproc, Mtwo and Neolix caused cracks in 92%, 80%, 68% and 48% of samples. ProTaper caused significantly more cracks than Neolix and Mtwo ( P <0.05). No significant differences were noted between other groups ( P >0.05). All rotary systems cause dentinal cracks and it is significantly different in apical, middle and coronal third of the root. Neolix appears to be a suitable alternative to other rotary systems since use of this single-file system saves time and cost and minimizes trauma to dentinal walls.
2018-01-01
Objectives To evaluate the mechanical properties and metallurgical characteristics of the M3 Rotary and M3 Pro Gold files (United Dental). Materials and Methods One hundred and sixty new M3 Rotary and M3 Pro Gold files (sizes 20/0.04 and 25/0.04) were used. Torque and angle of rotation at failure (n = 20) were measured according to ISO 3630-1. Cyclic fatigue resistance was tested by measuring the number of cycles to failure in an artificial stainless steel canal (60° angle of curvature and a 5-mm radius). The metallurgical characteristics were investigated by differential scanning calorimetry. Data were analyzed using analysis of variance and the Student-Newman-Keuls test. Results Comparing the same size of the 2 different instruments, cyclic fatigue resistance was significantly higher in the M3 Pro Gold files than in the M3 Rotary files (p < 0.001). No significant difference was observed between the files in the maximum torque load, while a significantly higher angular rotation to fracture was observed for M3 Pro Gold (p < 0.05). In the DSC analysis, the M3 Pro Gold files showed one prominent peak on the heating curve and 2 prominent peaks on the cooling curve. In contrast, the M3 Rotary files showed 1 small peak on the heating curve and 1 small peak on the cooling curve. Conclusions The M3 Pro Gold files showed greater flexibility and angular rotation than the M3 Rotary files, without decrement of their torque resistance. The superior flexibility of M3 Pro Gold files can be attributed to their martensite phase. PMID:29765904
Khoshbin, Elham; Donyavi, Zakiyeh; Abbasi Atibeh, Erfan; Roshanaei, Ghodratollah; Amani, Faranak
2018-01-01
Introduction: Endodontic rotary systems may result in dentinal cracks. They may propagate to vertical root fracture that compromises the outcome of endodontic treatment. This study aimed to compare Neolix and Reciproc (single-file systems), Mtwo and ProTaper (conventional rotary systems) in terms of dentinal crack formation in root canal walls. Methods and Materials: This in vitro study was conducted on 110 extracted human single-rooted teeth. The teeth were randomly divided into four experimental groups (n=25) for root canal preparation with Neolix, Reciproc, Mtwo and ProTaper systems and two control groups (n=5). The first control group underwent root canal instrumentation with hand files while the second control group received no preparation and was only irrigated. After instrumentation, root canals were horizontally sectioned at 3, 6 and 9 mm from the apex and inspected under a stereomicroscope under 12× magnification for detection of cracks. The data were analyzed using Chi-square, GEE test and Bonferroni tests (P<0.05). Results: No crack was found in the control groups. All rotary systems caused dentinal cracks. ProTaper, Reciproc, Mtwo and Neolix caused cracks in 92%, 80%, 68% and 48% of samples. ProTaper caused significantly more cracks than Neolix and Mtwo (P<0.05). No significant differences were noted between other groups (P>0.05). Conclusion: All rotary systems cause dentinal cracks and it is significantly different in apical, middle and coronal third of the root. Neolix appears to be a suitable alternative to other rotary systems since use of this single-file system saves time and cost and minimizes trauma to dentinal walls. PMID:29707009
White, Nicholas A; Danelson, Kerry A; Gayzik, F Scott; Stitzel, Joel D
2014-11-01
A finite element (FE) simulation environment has been developed to investigate aviator head and neck response during a simulated rotary-wing aircraft impact using both an FE anthropomorphic test device (ATD) and an FE human body model. The head and neck response of the ATD simulation was successfully validated against an experimental sled test. The majority of the head and neck transducer time histories received a CORrelation and analysis (CORA) rating of 0.7 or higher, indicating good overall correlation. The human body model simulation produced a more biofidelic head and neck response than the ATD experimental test and simulation, including change in neck curvature. While only the upper and lower neck loading can be measured in the ATD, the shear force, axial force, and bending moment were reported for each level of the cervical spine in the human body model using a novel technique involving cross sections. This loading distribution provides further insight into the biomechanical response of the neck during a rotary-wing aircraft impact.
Chan, W H; Chan, Alan H S
2003-01-01
This experiment studied strength and reversibility of direction-of-motion stereotypes and response times for different configurations of circular displays and rotary knobs. The effect of pointer position, instruction of turn direction, and control plane on movement compatibility was analyzed with precise quantitative measures of strength and reversibility index of stereotype. A comparison of results was made between a Computer Simulated Test and a Hardware Test with real rotary controls. There was consensus in the results of the two tests that strong and significantly reversible clockwise-for-clockwise (CC) and anticlockwise-for-anticlockwise (AA) stereotypes were obtained at the 12 o'clock position. Subjects' response times were found to be generally longer when there were no clear movement stereotypes. Nevertheless, differences of results were observed that while the CC and AA preferences were found to be dominant and reversible at all the planes and pointer positions in the Hardware Test, there was variation in the strength and reversibility of the two stereotypes amongst different testing configurations in the Simulated Test. This phenomenon was explained by the operating of the clockwise-for-right and anticlockwise-for-left principles, as shown in the analysis of contributions of component principles to the overall stereotype. The differences of results from the two tests were discussed with regard to simulation fidelity and it was suggested that a real Hardware Test should be used whenever possible for determination of design parameters of control panels in consideration of movement compatibility. Based on the Hardware Test, a pointer is recommended to be positioned at 12 o'clock position for check reading or resetting purpose, and the frontal plane is the best plane for positioning a rotary control with circular display. The results of this study provided significant implications for the industrial design of control panels used in man-machine interfaces for improved human performance.
Undergraduate students introduction to manual and rotary root canal instrumentation.
Leonardi, Denise Piotto; Haragushiku, Gisele Aihara; Tomazinho, Flavia Sens Fagundes; Furuse, Adilson Yoshio; Volpato, Lusiane; Baratto-Filho, Flares
2012-01-01
The aim of this study was to evaluate the performance of undergraduates in their first contact with manual and rotary root canal instrumentation. Forty-two students who had never worked on a root canal before instrumented 42 extracted lower-incisors. Participants were assigned to one of two groups: Rotary instrumentation or manual instrumentation. Pre- and post-operative computed tomography scans were obtained with a 3-dimensional dental imaging system. Starting and finishing times of preparation were recorded. The cross-sectional area of the root canal was analyzed with 2-mm-below-the-apex initial and final transverse images recorded through a digital imaging system and analyzed with software to measure the initial and final area of the root canal in mm(2). Data from the cross-sectional area of the root canal and time spent were subjected to the Mann-Whitney's U-test (p<0.05). The rotary instrumentation group showed smaller time for preparation (p=0.0204). No differences between rotary and manual instrumentation regarding the cross-sectional area of the root canal were observed (p=0.25). No accidents occurred. Undergraduate students showed good performance in their first contact with the manual and rotary instrumentation with regard to time spent and cross-sectional area of the root canal, with no operative accidents.
Mokhtari, Negar; Shirazi, Alireza-Sarraf
2017-01-01
Background Techniques with adequate accuracy of working length determination along with shorter duration of treatment in pulpectomy procedure seems to be essential in pediatric dentistry. The aim of the present study was to evaluate the accuracy of root canal length measurement with Root ZX II apex locator and rotary system in pulpectomy of primary teeth. Material and Methods In this randomized control clinical trial complete pulpectomy was performed on 80 mandibular primary molars in 80, 4-6-year-old children. The study population was randomly divided into case and control groups. In control group conventional pulpectomy was performed and in the case group working length was determined by electronic apex locator Root ZXII and instrumented with Mtwo rotary files. Statistical evaluation was performed using Mann-Whitney and Chi-Square tests (P<0.05). Results There were no significant differences between electronic apex locator Root ZXII and conventional method in accuracy of root canal length determination. However significantly less time was needed for instrumenting with rotary files (P=0.000). Conclusions Considering the comparable results in accuracy of root canal length determination and the considerably shorter instrumentation time in Root ZXII apex locator and rotary system, it may be suggested for pulpectomy in primary molar teeth. Key words:Rotary technique, conventional technique, pulpectomy, primary teeth. PMID:29302280
Mokhtari, Negar; Shirazi, Alireza-Sarraf; Ebrahimi, Masoumeh
2017-11-01
Techniques with adequate accuracy of working length determination along with shorter duration of treatment in pulpectomy procedure seems to be essential in pediatric dentistry. The aim of the present study was to evaluate the accuracy of root canal length measurement with Root ZX II apex locator and rotary system in pulpectomy of primary teeth. In this randomized control clinical trial complete pulpectomy was performed on 80 mandibular primary molars in 80, 4-6-year-old children. The study population was randomly divided into case and control groups. In control group conventional pulpectomy was performed and in the case group working length was determined by electronic apex locator Root ZXII and instrumented with Mtwo rotary files. Statistical evaluation was performed using Mann-Whitney and Chi-Square tests ( P <0.05). There were no significant differences between electronic apex locator Root ZXII and conventional method in accuracy of root canal length determination. However significantly less time was needed for instrumenting with rotary files ( P =0.000). Considering the comparable results in accuracy of root canal length determination and the considerably shorter instrumentation time in Root ZXII apex locator and rotary system, it may be suggested for pulpectomy in primary molar teeth. Key words: Rotary technique, conventional technique, pulpectomy, primary teeth.
Takahashi, Cristiane Midori; Cunha, Rodrigo Sanches; de Martin, Alexandre Sigrist; Fontana, Carlos Eduardo; Silveira, Cláudia Fernandes M; da Silveira Bueno, Carlos Eduardo
2009-11-01
Effective removal of gutta-percha in endodontic retreatment is a significant factor to ensure a favorable outcome from failed procedures. The purpose of this study was to evaluate the efficacy of a nickel-titanium rotary instrument system with or without a solvent versus stainless steel hand files for gutta-percha removal. Forty extracted human maxillary anterior teeth were prepared and filled. They were divided into 4 groups: Gates-Glidden and K-files, Gates-Glidden and K-files with chloroform, ProTaper Universal rotary retreatment system, and ProTaper Universal rotary retreatment system with chloroform. The operating time was recorded. The teeth were longitudinally sectioned and photographed. The images were analyzed and the filling remnants were quantified by using the IMAGE TOOL software. With Kruskall-Wallis test, statistical analysis showed that there was no significant difference between the techniques in regard to the amount of the endodontic filling remnants (P < .05); however, the ProTaper Universal rotary retreatment system was faster than the hand files (P < .05). All of the techniques proved helpful for the removal of endodontic filling material, and they were similar in material remaining after retreatment, but the ProTaper Universal rotary retreatment system without chloroform was faster.
Bürklein, S; Benten, S; Schäfer, E
2014-05-01
To assess in a laboratory setting the amount of apically extruded debris associated with different single-file nickel-titanium instrumentation systems compared to one multiple-file rotary system. Eighty human mandibular central incisors were randomly assigned to four groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the reciprocating single-file system Reciproc, the single-file rotary systems F360 and OneShape and the multiple-file rotary Mtwo instruments. The apically extruded debris was collected and dried in pre-weighed glass vials. The amount of debris was assessed with a micro balance and statistically analysed using anova and post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded. Reciproc produced significantly more debris compared to all other systems (P < 0.05). No significant difference was noted between the two single-file rotary systems and the multiple-file rotary system (P > 0.05). Instrumentation with the three single-file systems was significantly faster than with Mtwo (P < 0.05). Under the condition of this study, all systems caused apical debris extrusion. Rotary instrumentation was associated with less debris extrusion compared to reciprocal instrumentation. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Arias, Ana; de Vasconcelos, Rafaela Andrade; Hernández, Alexis; Peters, Ove A
2017-03-01
The purpose of this study was to assess the ex vivo torsional performance of a novel rotary system in small root canals after 2 different glide path preparations. Each independent canal of 8 mesial roots of mandibular molars was randomly assigned to achieve a reproducible glide path with a new set of either PathFile #1 (Dentsply Maillefer, Ballaigues, Switzerland) and #2 or ProGlider (Dentsply Maillefer) after negotiation with a 10 K-file. After glide path preparation, root canals in both groups were shaped with the same sequence of ProTaper Gold (Dentsply Tulsa Dental Specialties, Tulsa, OK) following the directions for use recommended by the manufacturer. A total of 16 new sets of each instrument of the ProTaper Gold (PTG) system were used. The tests were run in a standardized fashion in a torque-testing platform. Peak torque (Ncm) and force (N) were registered during the shaping procedure and compared with Student t tests after normal distribution of data was confirmed. No significant differences were found for any of the instruments in peak torque or force after the 2 different glide path preparations (P > .05). Data presented in this study also serve as a basis for the recommended torque for the use of PTG instruments. Under the conditions of this study, differences in the torsional performance of PTG rotary instruments after 2 different glide path preparations could not be shown. The different geometry of glide path rotary systems seemed to have no effect on peak torque and force induced by PTG rotary instruments when shaping small root canals in extracted teeth. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Taneja, Sonali; Kumari, Manju; Barua, Madhumita; Dudeja, Chetna; Malik, Meeta
2015-01-01
To compare the apical extrusion of Enterococcus faecalis after instrumentation with three different Ni-Ti rotary instruments- An in vitro study. In vitro study Methods and Material: Forty freshly extracted mandibular premolars were mounted in bacteria collection apparatus and root canals were contaminated with a suspension of Enterococcus faecalis. The contaminated teeth were divided into 4 groups of 10 teeth each according to rotary system used for instrumentation: Group1: Hyflex files, Group 2: GTX files, Group 3: Protaper files and Group 4: control group (no instrumentation). Bacteria extruded after preparations were collected into vials and microbiological samples were incubated in BHI broth for 24 hrs. The colony forming units were determined for each sample. Statistical analysis was done using one way ANOVA followed by post hoc independent " t" test. GTX files extruded least amount of bacteria followed by Hyflex files. Maximum extrusion of E. faecalis was seen in rotary Protaper group. Least amount of extrusion was seen with GTX files followed by Hyflex files and then rotary Protaper system.
da Frota, Matheus F; Espir, Camila G; Berbert, Fábio L C V; Marques, André A F; Sponchiado-Junior, Emílio C; Tanomaru-Filho, Mario; Garcia, Lucas F R; Bonetti-Filho, Idomeo
2014-12-01
As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.
Kashefinejad, Mohamad; Harandi, Azade; Eram, Saeed; Bijani, Ali
2016-01-01
Pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. Instrumentation techniques may affect the frequency and intensity of post-endodontic pain. This study aimed to compare single visit post endodontic pain using Mtwo (NiTi) rotary and hand K-file instruments. In this randomized controlled trial, 60 teeth with symptomatic irreversible pulpitis in 53 patients were selected and randomly assigned into two groups of 30 teeth. In group A, the root canals were prepared with Mtwo (NiTi) rotary instruments. In group B, the root canals were prepared with hand K-file instruments. Pain assessment was implemented using visual analog scale (VAS) at four, eight, 12 and 24 hours after treatment. The acquired data were analyzed using chi-square, Mann-Whitney U and Student's t-test (P<0.05). Patients treated with rotary instruments experienced significantly less post-endodontic pain than those treated with hand instruments (P<0.001). The use of Mtwo (NiTi) rotary instruments in root canal preparation contributed to lower incidence of postoperative pain than hand K-files.
Azar, Mohammad-Reza; Mokhtare, Maziar
2011-01-01
To compare the cleaning ability and preparation time of rotary instruments (Mtwo) and conventional manual instruments (K-file) in preparing primary and permanent molar root canals. Access cavities were prepared in 70 primary and 70 permanent teeth and India ink was injected into 120 canals of selected molars. The teeth were randomly divided into two main subgroups (n=20) and three control groups (n=10). In each of these main subgroups, either the manual instrument (K-file) or the rotary system (Mtwo) was used to prepare root canals. After cleaning the canals and clearing the teeth, dye removal was evaluated with the help of a stereomicroscope. In addition, the time needed for root canal preparation was recorded by a chronometer. Statistical analyses were done using the Kruskal-Wallis, Mann-Whitney and t tests. With regard to the cleaning ability of root canals, there were no significant differences between the K-file and Mtwo rotary system in primary and permanent teeth in the apical, middle or coronal third of the canals. Moreover, there were no significant differences between primary and permanent teeth prepared with K-files and rotary instruments. In all the groups, shorter times were recorded with the rotary technique. The working time was shorter in primary than in permanent teeth. The Mtwo rotary system showed acceptable cleaning ability in both primary and permanent teeth, and achieved results similar to those of K-files in less time.
NASA Astrophysics Data System (ADS)
Yang, C. S. Walter; DesRoches, Reginald
2014-03-01
This paper develops a smart hybrid rotary damper using a re-centering smart shape memory alloy (SMA) material as well as conventional energy-dissipating metallic plates that are easy to be replaced. The ends of the SMA and steel plates are inserted in the hinge. When the damper rotates, all the plates bend, providing energy dissipating and recentering characteristics. Such smart hybrid rotary dampers can be installed in structures to mitigate structural responses and to re-center automatically. The damaged energy-dissipating plates can be easily replaced promptly after an external excitation, reducing repair time and costs. An OpenSEES model of a smart hybrid rotary was established and calibrated to reproduce the realistic behavior measured from a full-scale experimental test. Furthermore, the seismic performance of a 3-story moment resisting model building with smart hybrid rotary dampers designed for downtown Los Angeles was also evaluated in the OpenSEES structural analysis software. Such a smart moment resisting frame exhibits perfect residual roof displacement, 0.006", extremely smaller than 18.04" for the conventional moment resisting frame subjected to a 2500 year return period ground motion for the downtown LA area (an amplified factor of 1.15 on Kobe earthquake). The smart hybrid rotary dampers are also applied into an eccentric braced steel frame, which combines a moment frame system and a bracing system. The results illustrate that adding smart hybrid rotaries in this braced system not only completely restores the building after an external excitation, but also significantly reduces peak interstory drifts.
The application of cast SiC/Al to rotary engine components
NASA Technical Reports Server (NTRS)
Stoller, H. M.; Carluccio, J. R.; Norman, J. P.
1986-01-01
A silicon carbide reinforced aluminum (SiC/Al) material fabricated by Dural Aluminum Composites Corporation was tested for various components of rotary engines. Properties investigated included hardness, high temperature strength, wear resistance, fatigue resistance, thermal conductivity, and expansion. SiC/Al appears to be a viable candidate for cast rotors, and may be applicable to other components, primarily housings.
Update on MTTF figures for linear and rotary coolers of Thales Cryogenics
NASA Astrophysics Data System (ADS)
van de Groep, W.; van der Weijden, H.; van Leeuwen, R.; Benschop, T.; Cauquil, J. M.; Griot, R.
2012-06-01
Thales Cryogenics has an extensive background in delivering linear and rotary coolers for military, civil and space programs. During the last years several technical improvements have increased the lifetime of all Thales coolers resulting in significantly higher Mean Time To Failure (MTTF) figures. In this paper not only updated MTTF values for most of the products in our portfolio will be presented but also the methodology used to come to these reliability figures will be explained. The differences between rotary and linear coolers will be highlighted including the different failure modes influencing the lifetime under operational conditions. These updated reliability figures are based on extensive test results for both rotary and linear coolers as well as Weibull analysis, failure mode identifications, various types of lifetime testing and field results of operational coolers. The impact of the cooler selection for typical applications will be outlined. This updated reliability approach will enable an improved tradeoff for cooler selection in applications where MTTF and a correct reliability assessment is key. Improbing on cooler selection and an increased insight in cooler reliability will result in a higher uptime and operability of equipment, less risk on unexpected failures and lower costs of ownership.
Liu, Rui; Kaiwar, Anjali; Shemesh, Hagay; Wesselink, Paul R; Hou, Benxiang; Wu, Min-Kai
2013-01-01
The aim of this study was to compare the incidence of apical root cracks and dentinal detachments after canal preparation with hand and rotary files at different instrumentation lengths. Two hundred forty mandibular incisors were mounted in resin blocks with simulated periodontal ligaments, and the apex was exposed. The root canals were instrumented with rotary and hand files, namely K3, ProTaper, and nickel-titanium Flex K files to the major apical foramen (AF), short AF, or beyond AF. Digital images of the apical surface of every tooth were taken during the apical enlargement at each file change. Development of dentinal defects was determined by comparing these images with the baseline image. Multinomial logistic regression test was performed to identify influencing factors. Apical crack developed in 1 of 80 teeth (1.3%) with hand files and 31 of 160 teeth (19.4%) with rotary files. Apical dentinal detachment developed in 2 of 80 teeth (2.5%) with hand files and 35 of 160 teeth (21.9%) with rotary files. Instrumentation with rotary files terminated 2 mm short of AF and did not cause any cracks. Significantly less cracks and detachments occurred when instrumentation with rotary files was terminated short of AF, as compared with that terminated at or beyond AF (P < .05). The AF deviated from the anatomic apex in 128 of 240 teeth (53%). Significantly more apical dentinal detachments appeared in teeth with a deviated AF (P = .033). Rotary instruments caused more dentinal defects than hand instruments; instrumentation short of AF reduced the risk of dentinal defects. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Mittal, Rakesh; Singla, Meenu G; Garg, Ashima; Dhawan, Anu
2015-12-01
Apical extrusion of irrigants and debris is an inherent limitation associated with cleaning and shaping of root canals and has been studied extensively because of its clinical relevance as a cause of flare-ups. Many factors affect the amount of extruded intracanal materials. The purpose of this study was to assess the bacterial extrusion by using manual, multiple-file continuous rotary system (ProTaper) and single-file continuous rotary system (One Shape). Forty-two human mandibular premolars were inoculated with Enterococcus faecalis by using a bacterial extrusion model. The teeth were divided into 3 experimental groups (n = 12) and 1 control group (n = 6). The root canals of experimental groups were instrumented according to the manufacturers' instructions by using manual technique, ProTaper rotary system, or One Shape rotary system. Sterilized saline was used as an irrigant, and bacterial extrusion was quantified as colony-forming units/milliliter. The results obtained were statistically analyzed by using one-way analysis of variance for intergroup comparison and post hoc Tukey test for pair-wise comparison. The level for accepting statistical significance was set at P < .05. All the instrumentation techniques resulted in bacterial extrusion, with manual step-back technique exhibiting significantly more bacterial extrusion than the engine-driven systems. Of the 2 engine-driven systems, ProTaper rotary extruded significantly more bacteria than One Shape rotary system (P < .05). The engine-driven nickel-titanium systems were associated with less apical extrusion. The instrument design may play a role in amount of extrusion. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Karataşlıoglu, E; Aydın, U; Yıldırım, C
2018-02-01
The aim of this in vitro study was to compare the static cyclic fatigue resistance of thermal treated rotary files with a conventional nickel-titanium (NiTi) rotary file. Four groups of 60 rotary files with similar file dimensions, geometries, and motion were selected. Groups were set as HyFlex Group [controlled memory wire (CM-Wire)], ProfileVortex Group (M-Wire), Twisted File Group (R-Phase Wire), and OneShape Group (conventional NiTi wire)] and tested using a custom-made static cyclic fatigue testing apparatus. The fracture time and fragment length of the each file was also recorded. Statistical analysis was performed using one-way analysis of variance and Tukey's test at the 95% confidence level (P = 0.05). The HyFlex group had a significantly higher mean cyclic fatigue resistance than the other three groups (P < 0.001). The OneShape groups had the least fatigue resistance. CM-Wire alloy represented the best performance in cyclic fatigue resistance, and NiTi alloy in R-Phase had the second highest fatigue resistance. CM and R-Phase manufacturing technology processed to the conventional NiTi alloy enhance the cyclic fatigue resistance of files that have similar design and size. M-wire alloy did not show any superiority in cyclic fatigue resistance when compared with conventional NiTi wire.
Chang, Yau-Zen; Liu, Mou-Chuan; Pai, Che-An; Lin, Chun-Li; Yen, Kuang-I
2011-06-01
This study investigates the application of non-destructive testing based on the impedance theory in the cyclic fatigue evaluation of endodontic Ni-Ti rotary instruments. Fifty Ni-Ti ProTaper instruments were divided into five groups (n=10 in Groups A to E). Groups A to D were subjected to cyclic fatigue within an artificial canal (Group E was the control group). The mean value of the total life limit (TLL), defined as the instrument being rotated until fracture occurred was found to be 104 s in Group A. Each rotary instrument in Groups B, C and D were rotated until the tested instruments reached 80% (84 s), 60% (62 s) and 40% (42 s) of the TLL. After fatigue testing, each rotary instrument was mounted onto a custom-developed non-destructive testing device to give the tip of the instrument a progressive sideways bend in four mutually perpendicular directions to measure the corresponding impedance value (including the resistance and the reactance). The results indicated that the impedance value showed the same trend as the resistance, implying that the impedance was primarily affected by the resistance. The impedance value for the instruments in the 80% and 60% TLL groups increased by about 6 mΩ (about 7.5%) more than that of the instruments in the intact and 40% TLL groups. The SEM analysis result showed that crack striations were only found at the tip of the thread on the cracked surface of the instrument, consistent with the impedance measurements that found the impedance value of the cracked surface to be significantly different from those in other surfaces. These findings indicate that the impedance value may represent an effective parameter for evaluating the micro-structural status of Ni-Ti rotary instruments subjected to fatigue loading. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Extended shelf-life (ESL) milk has a shelf life between that of high-temperature short-time (HTST) and ultrahigh temperature (UHT) pasteurized milk. ESL milk is usually pasteurized at temperatures exceeding 125 deg C which may give the milk a cooked taste. ESL milk produced using crossflow microfilt...
Bouton, Yvette; Buchin, Solange; Duboz, Gabriel; Pochet, Sylvie; Beuvier, Eric
2009-04-01
The effect of four associations of adjunct cultures composed of mesophilic lactobacilli and enterococci, either solely or combined, on the microbiological, biochemical and sensory characteristics of Swiss-type cheese made using microfiltered cows' milk and supplemented with propionibacteria was studied. The global pattern of growth was similar to that generally observed in raw milk cheese and interactions between microflora were highlighted during ripening. Enterococci, which negatively affected the survival of streptococci starters, seemed to play a limited role in the formation of volatile compounds, probably due to their low levels throughout ripening. On the contrary, mesophilic lactobacilli, which affected the evolution of propionibacteria, enterococci and L. delbrueckii subsp. lactis starter counts, modified free amino acid content, production of volatile compounds and organoleptic properties of mature cheese. This population appeared to be of major importance in the formation of cheese flavor as it was positively related to numerous potential flavor compounds such as alcohols and their corresponding esters, acetaldehyde and 4-methyl-4-heptanone. The original mesophilic lactobacilli present in milk could play an important role in the sensorial diversity of raw milk Swiss-type cheeses such as Comte.
NASA Astrophysics Data System (ADS)
Houben, Georg J.; Koeniger, Paul; Schloemer, Stefan; Gröger-Trampe, Jens; Sültenfuß, Jürgen
2018-02-01
Depth-specific sampling of groundwater is important for a variety of hydrogeological applications. Several sampling methods are available but comparably little is known about how their results compare. Therefore, samples from regular observation wells (short screen), micro-filters and direct push were compared for two sites with differing hydrogeological conditions and land use, both located in the Fuhrberger Feld, Germany. The encountered hydrochemical zonation requires a high resolution of 1 m or better, which the available small number of regular observation wells could only roughly mirror. Because the three methods employ significantly varying pumping rates and therefore, have varying spatial origins of the sample, individual concentrations at similar depths may differ significantly. In a hydrologically and chemically dynamical environment such as the agricultural site, this effect becomes more pronounced than for the more stable forest site. The micro-filters are probably the most depth-specific, but showed distinctly lower concentrations for dissolved gases than the other two methods, due to degassing during sampling. They should thus not be used for any method that relies on dissolved gas analysis.
Low-Cost Photolithographic Fabrication of Nanowires and Microfilters for Advanced Bioassay Devices
Doan, Nhi M.; Qiang, Liangliang; Li, Zhe; Vaddiraju, Santhisagar; Bishop, Gregory W.; Rusling, James F.; Papadimitrakopoulos, Fotios
2015-01-01
Integrated microfluidic devices with nanosized array electrodes and microfiltration capabilities can greatly increase sensitivity and enhance automation in immunoassay devices. In this contribution, we utilize the edge-patterning method of thin aluminum (Al) films in order to form nano- to micron-sized gaps. Evaporation of high work-function metals (i.e., Au, Ag, etc.) on these gaps, followed by Al lift-off, enables the formation of electrical uniform nanowires from low-cost, plastic-based, photomasks. By replacing Al with chromium (Cr), the formation of high resolution, custom-made photomasks that are ideal for low-cost fabrication of a plurality of array devices were realized. To demonstrate the feasibility of such Cr photomasks, SU-8 micro-pillar masters were formed and replicated into PDMS to produce micron-sized filters with 3–4 µm gaps and an aspect ratio of 3. These microfilters were capable of retaining 6 µm beads within a localized site, while allowing solvent flow. The combination of nanowire arrays and micro-pillar filtration opens new perspectives for rapid R&D screening of various microfluidic-based immunoassay geometries, where analyte pre-concentration and highly sensitive, electrochemical detection can be readily co-localized. PMID:25774709
NASA Technical Reports Server (NTRS)
Glass, Brian J.; Thompson, S.; Paulsen, G.
2010-01-01
Several proposed or planned planetary science missions to Mars and other Solar System bodies over the next decade require subsurface access by drilling. This paper discusses the problems of remote robotic drilling, an automation and control architecture based loosely on observed human behaviors in drilling on Earth, and an overview of robotic drilling field test results using this architecture since 2005. Both rotary-drag and rotary-percussive drills are targeted. A hybrid diagnostic approach incorporates heuristics, model-based reasoning and vibration monitoring with neural nets. Ongoing work leads to flight-ready drilling software.
The effect of alcohol blends on the performance of an air cooled Rotary Trochoidal Engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gutman, M.; Iuster, I.
Results obtained from tests on an air cooled Rotary Trochoidal Engine fueled with a gasoline-alcohol mixture, without modification of the carburetor, are presented in this paper. The tests were performed with one and two spark plugs. Amongst the obtained results, lower thermal load, better economy and improvement in cycling uniformity when running with two spark plugs were observed. The observed reduction in the rotor housing wall temperature and in the oil sump temperature presents particular advantages for an air cooled engine.
The effect of alcohol blends on the performance of an air cooled rotary trochoidal engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gutman, M.; Iuster, I.
Results obtained from tests on an air cooled Rotary Trochoidal Engine fueled with a gasoline-alcohol mixture, without modification of the carburetor, are presented in this paper. The tests were performed with one and two spark plugs. Amongst the obtained results, lower thermal load, better economy and improvement in cycling uniformity when running with two spark plugs were observed. The observed reduction in the rotor housing wall temperature and in the oil sump temperature presents particular advantages for an air cooled engine.
Pressure scanning choices - Rotary vs electronic
NASA Astrophysics Data System (ADS)
Pemberton, Addison
The choices available for present-day pressure scanning applications are described. Typical pressure scanning applications include wind tunnels, flight testing, turbine engine testing, process control, and laboratory/bench testing. The Scanivalve concept is discussed and it is noted that their use eliminates the cost of multiple individual pressure transducers and their signal conditioners as well as associated wiring for each pressure to be measured. However, they are limited to a maximum acquisition speed of 20 ports/sec/scanner. The advantages of electronic pressure scanners include in-situ calibration on demand, fast data acquisition speed, and high reliability. On the other hand, they are three times more expensive than rotary Scanivalves.
Hornby, Jonathan A; Robinson, Jim; Sterling, Milton
2017-03-01
The droplet spectrum of a mosquito adulticide spray plume determines its ability to drift through the target area, impinge on the mosquito, deliver a toxic dose, and the risk of environmental contamination. This paper provides data on droplet spectra produced from 6 nozzles in a high-pressure nozzle spray system and 5 rotary nozzle systems for common mosquito adulticides. Spray plume spectra were measured by laser diffraction. High-pressure nozzles were evaluated at pressures ranging from 500 psi to 6,000 psi. Rotary nozzles were evaluated at rotational speeds ranging from 500 rpm to 24,000 rpm. Measurements were made at wind speeds of 129 km/h (80 mph) to 225 km/h (140 mph). Adulticides included were Fyfanon ® , Aqua-Reslin ® , Dibrom ® , Duet ® , Permanone ® , and the inert mineral oil, Orchex ® 796. High-pressure nozzles produced spray plumes within the US Environmental Protection Agency (EPA) label requirements for all configurations tested except for one at a wind speed of 225 km/h, BETE ® MW125. Air speed had no significant effect on the spray plume volume median diameter (Dv (0.5) ) at the speeds tested with Fyfanon ® . The spray plume 90% drop volume diameter (Dv (0.9) ) significantly decreased, 13% at the higher wind speed of 225 km/h. Drop size was inversely related to pressure. Dilution of the product formulations increased the Dv (0.5) of the spray plume but it did not exceed the label requirements. For the PJ15 nozzle, orientation of the nozzle into the wind of up to 135° showed a significant increase in Dv (0.5) at 500 psi, 750 psi, and 1,500 psi. The Dv (0.5) varied <5 μm over the 3 angles examined for any specific pressure. Rotary nozzles produced spray plumes within the EPA label requirements for all test configurations examined. Air speed had no significant effect on Dv (0.5) or Dv (0.9) of the plume at speeds tested with Fyfanon for the ASC A20 nozzle. The rotary AU5000 nozzle using Orchex 796 produced plumes of larger drops in all configurations than any of the rotary nozzles of similar configurations using active ingredient formulations and within EPA label requirements.
ERIC Educational Resources Information Center
Brown, William R.; And Others
An evaluation was conducted of minority (Black, Hispanic, Asian, American Indian) and female performance in the Army's Initial Entry Rotary Wing flight training program. Each minority group was compared to a matched sample of majority students. The groups were matched on several test scores, education level, age, rank, and source of entry. The…
NASA Technical Reports Server (NTRS)
Mulcay, W. J.; Rose, R.
1980-01-01
Aerodynamic characteristics obtained in a helical flow environment utilizing a rotary balance located in the Langley spin tunnel are presented in plotted form. The configurations tested included the basic airplane, various control deflections, two canard locations, and wing leading edge modifications, as well as airplane components.
Alrahabi, Mothanna
2015-01-01
We evaluated the use of NiTi rotary and stainless steel endodontic instruments for canal shaping by undergraduate students. We also assessed the quality of root canal preparation as well as the occurrence of iatrogenic events during instrumentation. In total, 30 third-year dental students attending Taibah University Dental College prepared 180 simulated canals in resin blocks with NiTi rotary instruments and stainless steel hand files. Superimposed images were prepared to measure the removal of material at different levels from apical termination using the GSA image analysis software. Preparation time, procedural accidents, and canal shape after preparation were analyzed using χ 2 and t-tests. The statistical significance level was set at P < 0.05. There were significant differences in preparation time between NiTi instruments and stainless steel files; the former was associated with shorter preparation time, less ledge formation (1.1% vs. 14.4%), and greater instrument fracture (5.56% vs. 1.1%). These results indicate that NiTi rotary instruments result in better canal geometry and cause less canal transportation. Manual instrumentation using stainless steel files is safer than rotary instrumentation for inexperienced students. Intensive preclinical training is a prerequisite for using NiTi rotary instruments. These results prompted us to reconsider theoretical and practical coursework when teaching endodontics.
Surakanti, Jayaprada Reddy; Venkata, Ravi Chandra Polavarapu; Vemisetty, Hari Kumar; Dandolu, Ram Kiran; Jaya, Nagendra Krishna Muppalla; Thota, Shirisha
2014-01-01
Background and Aims: Extrusion of any debris during endodontic treatment may potentially cause post-operative complications such as flare-ups. The purpose of this in vitro study was to assess the amount of apically extruded debris during the root canal preparation using rotary and reciprocating nickel-titanium instrumentation systems. Materials and Methods: In this study, 60 human mandibular first premolars were randomly assigned to 3 groups (n = 20 teeth/group). The root canals were instrumented according to the manufacturers’ instructions using the Reciprocating single-file system WaveOne™ (Dentsply Maillefer, Ballaigues, Switzerland) and full-sequence rotary Hyflex CM™ (Coltene Whaledent, Allstetten, Switzerland) and ProTaper™ (Dentsply Maillefer, Ballaigues, Switzerland) instruments. The canals were then irrigated using bidistilled water. The debris that was extruded apically was collected in preweighed eppendorf tubes and assessed with an electronic balance and compared. Statistical Analysis Used: The debris extrusion was compared and statistically analyzed using analysis of variance and the post hoc Student-Newman-Keuls test. Results: The WaveOne™ and ProTaper™ rotary instruments produced significantly more debris compared with Hyflex CM™ rotary instruments (P < 0.05). Conclusions: Under the conditions of this study, all systems that were used resulted in extrusion of apical debris. Full-sequence rotary instrumentation was associated with less debris extrusion compared with the use of reciprocating single-file systems. PMID:24778507
Shankarappa, Pushpa; Misra, Abhinav; Sawhney, Asheesh; Sridevi, Nandamuri; Singh, Anu
2016-01-01
Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p < 0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects. PMID:27446636
The effects of cyclical axial motion on rotary endodontic instrument fatigue.
Dederich, D N; Zakariasen, K L
1986-02-01
A potential problem with the use of rotary engine-driven files to flare canals is metal fatigue and subsequent breakage. This study analyzes the effects of cyclical axial motion on instrument failure by fatigue testing of endodontic files with and without cyclical axial motion. Eighteen new instruments, sizes 15 to 45, were mounted in a lathe and turned at 1650 rpm in the lubricated lumen of a curved Pyrex capillary tube until failure occurred. Nine instruments of each size were turned with cyclical axial motion and nine were turned without it. The results indicated that cyclical axial motion can significantly extend the life span of rotary engine files. Torsional forces were not considered in this study.
Stratified charge rotary aircraft engine technology enablement program
NASA Technical Reports Server (NTRS)
Badgley, P. R.; Irion, C. E.; Myers, D. M.
1985-01-01
The multifuel stratified charge rotary engine is discussed. A single rotor, 0.7L/40 cu in displacement, research rig engine was tested. The research rig engine was designed for operation at high speeds and pressures, combustion chamber peak pressure providing margin for speed and load excursions above the design requirement for a high is advanced aircraft engine. It is indicated that the single rotor research rig engine is capable of meeting the established design requirements of 120 kW, 8,000 RPM, 1,379 KPA BMEP. The research rig engine, when fully developed, will be a valuable tool for investigating, advanced and highly advanced technology components, and provide an understanding of the stratified charge rotary engine combustion process.
Kashefinejad, Mohamad; Harandi, Azade; Bijani, Ali
2016-01-01
Objectives: Pain is an unpleasant outcome of endodontic treatment that can be unbearable to patients. Instrumentation techniques may affect the frequency and intensity of post-endodontic pain. This study aimed to compare single visit post endodontic pain using Mtwo (NiTi) rotary and hand K-file instruments. Materials and Methods: In this randomized controlled trial, 60 teeth with symptomatic irreversible pulpitis in 53 patients were selected and randomly assigned into two groups of 30 teeth. In group A, the root canals were prepared with Mtwo (NiTi) rotary instruments. In group B, the root canals were prepared with hand K-file instruments. Pain assessment was implemented using visual analog scale (VAS) at four, eight, 12 and 24 hours after treatment. The acquired data were analyzed using chi-square, Mann-Whitney U and Student’s t-test (P<0.05). Results: Patients treated with rotary instruments experienced significantly less post-endodontic pain than those treated with hand instruments (P<0.001). Conclusions: The use of Mtwo (NiTi) rotary instruments in root canal preparation contributed to lower incidence of postoperative pain than hand K-files. PMID:27536323
Dynamic analysis and vibration testing of CFRP drive-line system used in heavy-duty machine tool
NASA Astrophysics Data System (ADS)
Yang, Mo; Gui, Lin; Hu, Yefa; Ding, Guoping; Song, Chunsheng
2018-03-01
Low critical rotary speed and large vibration in the metal drive-line system of heavy-duty machine tool affect the machining precision seriously. Replacing metal drive-line with the CFRP drive-line can effectively solve this problem. Based on the composite laminated theory and the transfer matrix method (TMM), this paper puts forward a modified TMM to analyze dynamic characteristics of CFRP drive-line system. With this modified TMM, the CFRP drive-line of a heavy vertical miller is analyzed. And the finite element modal analysis model of the shafting is established. The results of the modified TMM and finite element analysis (FEA) show that the modified TMM can effectively predict the critical rotary speed of CFRP drive-line. And the critical rotary speed of CFRP drive-line is 20% higher than that of the original metal drive-line. Then, the vibration of the CFRP and the metal drive-line were tested. The test results show that application of the CFRP drive shaft in the drive-line can effectively reduce the vibration of the heavy-duty machine tool.
Li, Uei-Ming; Shin, Chow-Shing; Lan, Wan-Hong; Lin, Chun-Pin
2006-06-01
The purpose of this study was to investigate the application of nondestructive testing in cyclic fatigue evaluation of endodontic ProFile nickel-titanium (NiTi) rotary instruments. As-received ProFile instruments were made to rotate freely in sloped metal blocks by a contra-angle handpiece mounted on a testing machine. Rotation was interrupted periodically, and the instrument removed and engaged onto a device to monitor its stiffness by using two strain gauges in four different directions. This monitoring method has the potential to be developed into a convenient, nondestructive turnkey system that allows in situ assessment of the integrity of NiTi instruments in the clinic. Upon fracture, which was indicated by a change in instrument stiffness, the fractured surface would be examined under a scanning electron microscope. Microscopic evaluation indicated a small area of fatigue fracture with a large area of final ductile fracture, whereby the latter was the major cyclic failure mode. Based on the results of this study, we concluded that a potential nondestructive integrity assessment method for NiTi rotary instruments was developed.
Straight-Pore Microfilter with Efficient Regeneration
NASA Technical Reports Server (NTRS)
Liu, Han; LaConti, Anthony B.; McCallum. Thomas J.; Schmitt, Edwin W.
2010-01-01
A novel, high-efficiency gas particulate filter has precise particle size screening, low pressure drop, and a simple and fast regeneration process. The regeneration process, which requires minimal material and energy consumption, can be completely automated, and the filtration performance can be restored within a very short period of time. This filter is of a novel material composite that contains the support structure and a novel coating.
Integrated Device for Circulating Tumor Cell Capture, Characterization and Lens-Free Microscopy
2012-08-01
peripheral blood of breast cancer patients indicates high metastatic potential and increased morbidity. Development of a cost - effective CTC detection and...microfilter platform captures CTC from the cancer patients’ blood cost effectively , where the larger CTC are preferentially retained on the membrane...development of a cost - effective and high-throughput CTC analysis system would revolutionize the field of CTC detection, prognosis, and therapeutic
Root Canal Cleaning Efficacy of Rotary and Hand Files Instrumentation in Primary Molars
Nazari Moghaddam, Kiumars; Mehran, Majid; Farajian Zadeh, Hamideh
2009-01-01
INTRODUCTION: Pulpectomy of primary teeth is commonly carried out with hand files and broaches; a tricky and time consuming procedure. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous molars using hand K-files and Flex Master rotary system. MATERIALS AND METHODS: In this study, 68 canals of 23 extracted primary molars with at least two third intact roots and 7-12 mm length were selected. After preparing an access cavity, K-file size #15 was introduced into the root canal and India ink was injected with an insulin syringe. Sixty samples were randomly divided in to experimental groups in group I (n=30), root canals were prepared with hand K-files; in group II (n=30), rotary Flex Master files were used for instrumentation, and in group III 8 remained samples were considered as negative controls. After clearing and root sectioning, the removal of India ink from cervical, middle, and apical thirds was scored. Data was analyzed using student's T-test and Mann-Whitney U test. RESULTS: There was no significant difference between experimental groups cleaning efficacy at the cervical, middle and apical root canal thirds. Only the coronal third scored higher in the hand instrumented group (P<0.001). Instrumentation with Flex Master rotary files was significantly less time consuming (P<0.001). CONCLUSION: Although there was no difference in cleanliness efficacy at the apical and middle thirds, the coronal third was more effectively cleaned with hand files. Predictably, time efficiency was a significant advantage with rotary technique. PMID:23940486
Influence of axial movement on fatigue of ProFile Ni-Ti rotary instruments: an in vitro evaluation.
Avoaka, Marie-Chantal; Haïkel, Youssef
2010-05-01
The aim of this study was to evaluate the influence of the axial movement and the angle of curve (in degrees) on fatigue of nickel-titanium (Ni-Ti) ProFile rotary endodontic instruments. Ni-Ti ProFile rotary instruments (Maillefer SA, Ballaigues, Switzerland), 25 mm long in the range of ISO size 15 to 40 with two tapers (0.4 and 0.6) were evaluated. They are divided in two groups: the instruments with axial movement and those without axial movement. The system used to test the fatigue is maintained in mechanical conditions as close as possible to the clinical situation. The axial movement is in the order of 2 mm in corono-apical direction with a frequency of 1 Hz. The concave radii incorporating a notched V-form for guiding the instruments were: 5; 7,5 and 10 mm. The rotary system is mounted on an electric handpiece and rotated at 350 rpm speed as recommended by the manufacturers. The instruments are rotated until their separation, and the time, in seconds, is recorded. Statistical evaluation is undertaken using a two-way t-test to identify significant differences between variables in the study (p <0.05). We found significant statistical difference (p<0.05) between Ni-Ti engine drive ProFile instruments incorporating an axial movement and the instruments without axial movement with the same radius of curvature, size and taper.The incorporation of the axial movement increases significantly the life-span of the ProFile rotary instruments. This should reduce the risk of the instrument separation during the endodontic treatment.
Nagi, Sana Ehsen; Khan, Farhan Raza
2017-01-01
With root canal treatment, the organic debris and micro-organisms from pulp space is removed and an ideal canal preparation is achieved that is conducive of hermetic obturation. The purpose of this study was to correlate the pre-operative canal curvature with the postoperative curvature in human extracted teeth prepared with K-3 rotary systems. The root canal preparation was carried out on extracted human molars and premolars using K-3 endodontic rotary files. A pre and post-operative image of the teeth using digital radiograph were taken in order to compare pre and post-operative canal curvature. The images were saved in an images retrieval system (Gendex software, USA). Change in the canal curvature was measured using the software measuring tool (Vixwin software, USA). Student paired t-test and Pearson correlation test was applied at 0.05 level of significance. There is a statistically significant difference between pre-operative and post-operative canal curvature (p-value <0.001) and a strong positive correlation (91% correlation) between pre-operative and post-operative canal curvature in teeth prepared with the K-3 rotary files. A significant difference between pre and post instrumentation curvature was found. Degree of canal curvature was not correlated with time taken for canal preparation.
Thermal treatment of medical waste in a rotary kiln.
Bujak, J
2015-10-01
This paper presents the results of a study of an experimental system with thermal treatment (incineration) of medical waste conducted at a large complex of hospital facilities. The studies were conducted for a period of one month. The processing system was analysed in terms of the energy, environmental and economic aspects. A rotary combustion chamber was designed and built with the strictly assumed length to inner diameter ratio of 4:1. In terms of energy, the temperature distribution was tested in the rotary kiln, secondary combustion (afterburner) chamber and heat recovery system. Calorific value of medical waste was 25.0 MJ/kg and the thermal efficiency of the entire system equalled 66.8%. Next, measurements of the pollutant emissions into the atmosphere were performed. Due to the nature of the disposed waste, particular attention was paid to the one-minute average values of carbon oxide and volatile organic compounds as well as hydrochloride, hydrogen fluoride, sulphur dioxide and total dust. Maximum content of non-oxidized organic compounds in slag and bottom ash were also verified during the analyses. The best rotary speed for the combustion chamber was selected to obtain proper afterburning of the bottom slag. Total organic carbon content was 2.9%. The test results were used to determine the basic economic indicators of the test system for evaluating the profitability of its construction. Simple payback time (SPB) for capital expenditures on the implementation of the project was 4 years. Copyright © 2015 Elsevier Ltd. All rights reserved.
F/A-18 forebody vortex control. Volume 2: Rotary-balance tests
NASA Technical Reports Server (NTRS)
Kramer, Brian R.; Suarez, Carlos J.; Malcolm, Gerald N.; Ayers, Bert F.
1994-01-01
A rotary-balance wind tunnel test was conducted on a six percent model of the F/A-18 at the NASA Ames 7 X 10-Foot Low Speed Wind Tunnel. The data reduction was specially written for the test in National Instruments' LabVIEW. The data acquisition, reduction and analysis was performed with a Macintosh computer. The primary objective of the test was to evaluate the effectiveness of several forebody vortex control configurations in a rotary flow field. The devices that were found to be the most effective during the static tests (Volume 1) were investigated and included both mechanical and pneumatic configurations. The mechanical systems evaluated were small, single and dual, rotating nose tip strakes and a vertical nose strake. The jet blowing configuration used nozzles canted inboard 60 degrees. A two segment tangential slot was also evaluated. The different techniques were evaluated at angles of attack of 30 degrees, 45 degrees, 51 degrees, and 60 degrees. Sideslip and Reynolds number were varied for some of the configurations. All of the techniques proved to be effective in the rotating flow field. The vertical nose strake had the largest 'envelope' of effectiveness. Forebody vortex control provides large, robust yawing moments at medium to high angles of attack, even during combat maneuvers such as loaded roll.
Three axis electronic flight motion simulator real time control system design and implementation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gao, Zhiyuan; Miao, Zhonghua, E-mail: zhonghua-miao@163.com; Wang, Xiaohua
2014-12-15
A three axis electronic flight motion simulator is reported in this paper including the modelling, the controller design as well as the hardware implementation. This flight motion simulator could be used for inertial navigation test and high precision inertial navigation system with good dynamic and static performances. A real time control system is designed, several control system implementation problems were solved including time unification with parallel port interrupt, high speed finding-zero method of rotary inductosyn, zero-crossing management with continuous rotary, etc. Tests were carried out to show the effectiveness of the proposed real time control system.
Evaluation of Thermal Barrier and PS-200 Self-Lubricating Coatings in an Air-Cooled Rotary Engine
NASA Technical Reports Server (NTRS)
Moller, Paul S.
1995-01-01
This project provides an evaluation of the feasibility and desirability of applying a thermal barrier coating overlaid with a wear coating on the internal surfaces of the combustion area of rotary engines. Many experiments were conducted with different combinations of coatings applied to engine components of aluminum, iron and titanium, and the engines were run on a well-instrumented test stand. Significant improvements in specific fuel consumption were achieved and the wear coating, PS-200, which was invented at NASA's Lewis Research Center, held up well under severe test conditions.
Three axis electronic flight motion simulator real time control system design and implementation.
Gao, Zhiyuan; Miao, Zhonghua; Wang, Xuyong; Wang, Xiaohua
2014-12-01
A three axis electronic flight motion simulator is reported in this paper including the modelling, the controller design as well as the hardware implementation. This flight motion simulator could be used for inertial navigation test and high precision inertial navigation system with good dynamic and static performances. A real time control system is designed, several control system implementation problems were solved including time unification with parallel port interrupt, high speed finding-zero method of rotary inductosyn, zero-crossing management with continuous rotary, etc. Tests were carried out to show the effectiveness of the proposed real time control system.
NASA Technical Reports Server (NTRS)
Young, L. A.; Derby, M. R.; Demblewski, R.; Navarrete, J.
2002-01-01
This paper details ongoing work at NASA Ames Research Center as to experimental investigations and demonstrations related to rotary-wing technologies that might be applied to flight in the atmosphere of Mars. Such Mars rotorcraft would provide a 'three-dimensional mobility' to the exploration of the Red Planet. Preliminary results from isolated rotor testing in Mars-representative atmospheric densities, as well as progress towards coaxial test stand development are discussed. Additionally, work towards the development and use of surrogate flight vehicles -- in the terrestrial environment -- to demonstrate key technologies is also summarized.
Comparison of removed dentin thickness with hand and rotary instruments
Shahriari, Shahriar; Abedi, Hasan; Hashemi, Mahdi; Jalalzadeh, Seyed Mohsen
2009-01-01
INTRODUCTION: The aim of this study was to evaluate the amount of dentine removed after canal preparation using stainless steel (SS) hand instruments or rotary ProFile instruments. MATERIALS AND METHODS: Thirty-six extracted human teeth with root canal curvatures less than 30º were embedded in clear polyester resin. The roots were cut horizontally at apical 2, 4 and 7 mm. Dentin thickness was measured at each section and the sections were accurately reassembled using a muffle. Root canals were randomly prepared by SS hand instruments or rotary ProFile instruments. Root sections were again separated, and the remaining dentin thickness was measured. Mann-Whitney U and t tests were performed for analytic comparison of the results. RESULTS: The thickness of removed dentin was significantly different between the two used methods (P<0.05). Significantly greater amounts of dentin was removed mesially in all sections in hand instrumentation group (P<0.001). CONCLUSION: ProFile rotary instrumentation prepares root canals with a greater conservation of tooth structure. PMID:23940489
Pasqualini, Damiano; Scotti, Nicola; Tamagnone, Lorenzo; Ellena, Federica; Berutti, Elio
2008-03-01
The aim of this study was to compare the effective shaping time and number of rotations required by an endodontist working with hand and rotary ProTaper instruments to completely shape simulated root canals. Eighty Endo Training Blocks (curved canal shape) were used. Manual preflaring was performed with K-Flexofiles #08-10-12-15-17 and #20 Nitiflex at a working length of 18 mm. Specimens were then randomly assigned to 2 different groups (n = 40); group 1 was shaped by using hand ProTaper and group 2 with ProTaper rotary. The number of rotations made in the canal and the effective time required to achieve complete canal shaping were recorded for each instrument. Differences between groups were analyzed with the nonparametric Mann-Whitney U test (P < .05). Hand ProTaper required significantly fewer rotations (P < .001) than rotary ProTaper, whereas the effective working time to fully shape the simulated canal was significantly higher (P < .001) with hand ProTaper.
Multi-Fuel Rotary Engine for General Aviation Aircraft
NASA Technical Reports Server (NTRS)
Jones, C.; Ellis, D. R.; Meng, P. R.
1983-01-01
Design studies, conducted for NASA, of Advanced Multi-fuel General Aviation and Commuter Aircraft Rotary Stratified Charge Engines are summarized. Conceptual design studies of an advanced engine sized to provide 186/250 shaft KW/HP under cruise conditions at 7620/25,000 m/ft. altitude were performed. Relevant engine development background covering both prior and recent engine test results of the direct injected unthrottled rotary engine technology, including the capability to interchangeably operate on gasoline, diesel fuel, kerosene, or aviation jet fuel, are presented and related to growth predictions. Aircraft studies, using these resultant growth engines, define anticipated system effects of the performance and power density improvements for both single engine and twin engine airplanes. The calculated results indicate superior system performance and 30 to 35% fuel economy improvement for the Rotary-engine airplanes as compared to equivalent airframe concept designs with current baseline engines. The research and technology activities required to attain the projected engine performance levels are also discussed.
Shaping ability of nickel-titanium rotary instruments in curved root canals.
Talati, Ali; Moradi, Saeed; Forghani, Maryam; Monajemzadeh, Ali
2013-01-01
Disinfection and subsequent obturation of the root canal space require adequate mechanical enlargement of the canals. The purpose of this in vitro study was to compare the shaping ability of Mtwo, RaCe and Medin rotary instruments during the preparation of curved root canals. Sixty mesiobuccal root canals of mandibular molars with severe curvatures between 25-35(°) and radius of 4-9 mm were randomly divided into three groups of 20 canals each. Using pre- and post-instrumentation radiographs, straightening of the canal and the apical transportation were determined with AutoCAD software. The data were analyzed using Chi square, analysis of variance, and post-hoc tests and the significance level was set at P<0.05. Mtwo instruments maintained the canal curvature significantly better than Race and Medin instruments (P<0.05). There was significant difference between the rotary instruments for iatrogenic transportation of the major foramen (P>0.05). Under the conditions of this in vitro study, Mtwo instruments seemed superior to the two other rotary instruments.
Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments.
Alapati, Satish B; Brantley, William A; Iijima, Masahiro; Clark, William A T; Kovarik, Libor; Buie, Caesar; Liu, Jie; Ben Johnson, William
2009-11-01
A novel thermomechanical processing procedure has been developed that yields a superelastic (SE) nickel-titanium (NiTi) wire (M-Wire) that laboratory testing shows has improved mechanical properties compared with conventional SE austenitic NiTi wires used for manufacture of rotary instruments. The objective of this study was to determine the origin of the improved mechanical properties. Specimens from 2 batches of M-Wire prepared under different processing conditions and from 1 batch of standard-processed SE wire for rotary instruments were examined by scanning transmission electron microscopy, temperature-modulated differential scanning calorimetry, micro-x-ray diffraction, and scanning electron microscopy with x-ray energy-dispersive spectrometric analyses. The processing for M-Wire yields a microstructure containing martensite, that the proportions of NiTi phases depend on processing conditions, and that the microstructure exhibits pronounced evidence of alloy strengthening. The presence of Ti(2)Ni precipitates in both microstructures indicates that M-Wire and the conventional SE wire for rotary instruments are titanium-rich.
Multi-fuel rotary engine for general aviation aircraft
NASA Technical Reports Server (NTRS)
Jones, C.; Ellis, D. R.; Meng, P. R.
1983-01-01
Design studies of advanced multifuel general aviation and commuter aircraft rotary stratified charge engines are summarized. Conceptual design studies were performed at two levels of technology, on advanced general aviation engines sized to provide 186/250 shaft kW/hp under cruise conditions at 7620 (25000 m/ft) altitude. A follow on study extended the results to larger (2500 hp max.) engine sizes suitable for applications such as commuter transports and helicopters. The study engine designs were derived from relevant engine development background including both prior and recent engine test results using direct injected unthrottled rotary engine technology. Aircraft studies, using these resultant growth engines, define anticipated system effects of the performance and power density improvements for both single engine and twin engine airplanes. The calculated results indicate superior system performance and 27 to 33 percent fuel economy improvement for the rotary engine airplanes as compared to equivalent airframe concept designs with current baseline engines. The research and technology activities required to attain the projected engine performance levels are also discussed.
Fragmentation of Newtonian and viscoelastic liquids during rotary atomization
NASA Astrophysics Data System (ADS)
Keshavarz, Bavand; Moore, John; Houze, Eric; Koerner, Michael; McKinley, Gareth; MIT Collaboration; Axalta Coating Systems Collaboration
2015-11-01
Animals drying their wet fur by rapidly shaking their body and rotary atomization in paint coating are just a few examples in which centripetal acceleration is used to disintegrate liquid films into smaller fragments. Narrower size distributions and well-defined geometrical fluid pathlines (similar to the involute of a circle) are the main advantages of this type of atomization as compared to air-assisted atomization. Despite these inherent advantages there is a paucity of fundamental knowledge about the roles of fluid rheology in this process. We study the effects of viscosity by performing rotary atomization tests on silicone oils with a wide range of viscosities (1-1000 mPa.s). Viscoelastic effects are also probed by spraying solutions of polyethylene oxide (PEO) dissolved in water at different concentrations. Our results show that understanding the effects of liquid properties on the instabilities that control rotary atomization (primarily Rayleigh-Taylor instability during the ligament formation followed by Rayleigh-Plateau instability during droplet pinch-off) can help us understand the resulting fragment size distributions.
The effect of root canal preparation on the development of dentin cracks.
Milani, Amin Salem; Froughreyhani, Mohammad; Rahimi, Saeed; Jafarabadi, Mohammad Asghari; Paksefat, Sara
2012-01-01
Root fracture is not an instant phenomenon but a result of gradual development of tiny craze lines in tooth structure. Recent studies have shown that canal instrumentation has the potential to cause dentinal cracks. The purpose of this study was to evaluate and compare the formation of dentinal cracks caused by ProTaper rotary system to hand instrumentation. This in vitro study was carried out using 57 mandible incisor teeth. The teeth were decoronated. The roots were then examined to exclude cracked samples. A standard model for PDL simulation was used. The teeth were randomly divided into two experimental and one control group (n=19). The teeth in the experimental groups were prepared using hand or ProTaper Universal rotary instrumentation. The teeth in the control group were left unprepared. The teeth were then sectioned horizontally 3 and 6 mm from the apex, and the number of various dentinal defects was recorded using a dental operating microscope. The differences between groups were analyzed with Fisher's exact test. The hand group demonstrated significantly more defects than the control group (P=0.001). However, there was no significant difference between the rotary compared to the control and hand groups (P>0.05). There was no significant difference between groups with regards to fracture (P>0.05). Other defects including internal, external and surface cracks were more frequent in the hand than in the control or rotary groups (P=0.02), but the difference was not significant between the rotary and control groups (P>0.05). Canal preparation, whether hand or rotary, produces structural defects in dentin. The ProTaper rotary system when used according to the manufacturer's instructions, tends to produce fewer cracks and can be considered a safe preparation technique.
Celik, Davut; Taşdemir, Tamer; Er, Kürşat
2013-02-01
Some improvements have been developed with new generations of nickel-titanium (NiTi) rotary instruments that led to their successful and extensive application in clinical practice. The purpose of this in vitro study was to compare the root canal preparations performed by using GT Series X and Twisted File systems produced by innovative manufacturing process with Revo-S, RaCe, Mtwo, and ProTaper Universal systems manufactured directly from conventional nitinol and with stainless steel K-Flexofile instruments. The mesiobuccal root canals of 140 maxillary first permanent molars that had between 30°-40° curvature angle and 4- to 9-mm curvature radius of the root canal were used. After root canal preparations made by using GT Series X, Twisted File, Revo-S, RaCe, Mtwo, and ProTaper Universal NiTi rotary systems and stainless steel K-Flexofile instruments, transportation occurred in the root canal, and alteration of working length (WL) was assessed by using a modified double-digital radiographic technique. The data were compared by the post hoc Tukey honestly significant difference test. NiTi rotary systems caused less canal transportation and alteration of WL than K-Flexofile instruments (P < .05). There was no significant difference between NiTi rotary system groups at any levels (P > .05) except 2.5 mm from the WL. At this level ProTaper Universal system caused significant canal transportation (P < .05). GT Series X and Twisted File rotary systems produced with innovative process were concluded to shape the curved canals to result in minimal canal transportation, similar to Revo-S, RaCe, Mtwo, and ProTaper Universal rotary systems manufactured by traditional methods. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Enhanced photodegradation of phenolic compounds by adding TiO2 to soil in a rotary reactor.
Wang, Jing-xian; Chen, Shuo; Quan, Xie; Zhao, Hui-min; Zhao, Ya-zhi
2006-01-01
Photodegradation of pentachlorophenol (PCP) and p-nitrophenol (PNP) in soil was carried out in a designed rotary reactor, which can provide the soil particles with continually uniform irradiation, and on a series of thin soil layers. TiO2, as a kind of environmental friendly photocatalyst, was introduced to the soil to enhance the processes. Compared with that on the soil layers, photodegradation of PCP at initial concentration of 60 mg/kg was improved dramatically in the rotary reactor no matter whether TiO2 was added, with an increase of 3.0 times in the apparent first-order rate constants. The addition of 1 wt% TiO2 furthered the improvement by 1.4 times. Without addition of TiO2, PNP (initial concentration of 60 mg/kg) photodegradation rate in the rotary reactor was similar to that on the soil layers. When 1 wt% additional TiO2 was added, PNP photodegradation was enhanced obviously, and the enhancement in the rotary reactor was 2 times of that on the soil layers, which may be attributed to the higher frequency of the contact between PNP on soil particles and the photocatalyst. The effect of soil pH and initial concentrations of the target compounds on the photodegradation in the rotary reactor was investigated. The order of the degradation rate at different soil pH was relative to the aggregation of soil particles during mixing in the rotary reactor. Photodegradation of PCP and PNP at different initial concentrations showed that addition of TiO2 to enhance the photodegradation was more suitable for contaminated soil with higher concentration of PCP, while was effective for contaminated soil at each PNP concentration tested in our study.
Consideration of Sludge Formation in HFC-134a / Polyol Ester oil Refrigeration System
NASA Astrophysics Data System (ADS)
Yamamoto, Tsutomu; Yamamoto, Tethuya; Simizu, Yasuhiko; Nakayama, Yoshinori; Takizawa, Kikuo
A refrigeration test employing HFC-134a and polyol ester oil was carried out in order to make clear the causes of the sludge formation in the capillary tube. Compressors used were two types: a hermetic reciprocating compressor and a rotary compressor. Installed dryer contained desiccant of the compound zeolite type. The results showed that the amount of capillary sludge increased as the compressor temperature rose. The capillary sludge was determined to consist of desiccant and metal dust for the reciprocating compressor, and of tar-like substance for the rotary compressor. Thermal stability test which was used to check the degree of deterioration of the ester oil, suggested that the presence of desiccant and high compressor temperature might produce tar-like substance by the break down and polymerization of the ester oil. In addition, it was confirmed that factors affecting the sludge formation were the dirtiness of the refrigeration circuit for the reciprocating compressor, and the presence of desiccant, for the rotary compressor.
Cyclic fatigue of ProFile rotary instruments after prolonged clinical use.
Gambarini, G
2001-07-01
The purpose of the present study was to evaluate resistance to cyclic fatigue of new and used ProFile Ni-Ti rotary instruments. Used instruments were operated in 10 clinical cases using passive instrumentation and a crown-down preparation technique. Cyclic fatigue testing of new and used engine-driven instruments was then performed with a specific device which allowed the instruments to rotate freely inside a stainless steel artificial canal, whilst maintaining conditions close to the clinical situation. Instruments were rotated until fracture occurred and time to fracture was visually recorded with a chronometer. A significant reduction of rotation time to breakage (life span) was noted between new and used instruments. In all sizes new instruments were significantly more resistant than used ones (two-sample t-test, P < 0.01). No instrument underwent intracanal failure during clinical use. Prolonged clinical use of Ni-Ti engine-driven instruments significantly reduced their cyclic fatigue resistance. Nevertheless, each rotary instrument was successfully operated in up to 10 clinical cases without any intracanal failure.
Bürklein, Sebastian; Tsotsis, Polymnia; Schäfer, Edgar
2013-04-01
The purpose of this study was to evaluate the incidence of dentinal defects after root canal preparation with reciprocating instruments (Reciproc and WaveOne) and rotary instruments. One hundred human central mandibular incisors were randomly assigned to 5 groups (n = 20 teeth per group). The root canals were instrumented by using the reciprocating single-file systems Reciproc and WaveOne and the full-sequence rotary Mtwo and ProTaper instruments. One group was left unprepared as control. Roots were sectioned horizontally at 3, 6, and 9 mm from the apex and evaluated under a microscope by using 25-fold magnification. The presence of dentinal defects (complete/incomplete cracks and craze lines) was noted and analyzed by using the chi-square test. No defects were observed in the controls. All canal preparation created dentinal defects. Overall, instrumentation with Reciproc was associated with more complete cracks than the full-sequence files (P = .021). Although both reciprocating files produced more incomplete cracks apically (3 mm) compared with the rotary files (P = .001), no statistically significant differences were obtained concerning the summarized values of all cross sections (P > .05). Under the conditions of this study, root canal preparation with both rotary and reciprocating instruments resulted in dentinal defects. At the apical level of the canals, reciprocating files produced significantly more incomplete dentinal cracks than full-sequence rotary systems (P < .05). Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Khanna, Rajesh; Handa, Aashish; Virk, Rupam Kaur; Ghai, Deepika; Handa, Rajni Sharma; Goel, Asim
2017-01-01
The process of cleaning and shaping the canal is not an easy goal to obtain, as canal curvature played a significant role during the instrumentation of the curved canals. The present in vivo study was conducted to evaluate procedural errors during the preparation of curved root canals using hand Nitiflex and rotary K3XF instruments. Procedural errors such as ledge formation, instrument separation, and perforation (apical, furcal, strip) were determined in sixty patients, divided into two groups. In Group I, thirty teeth in thirty patients were prepared using hand Nitiflex system, and in Group II, thirty teeth in thirty patients were prepared using K3XF rotary system. The evaluation was done clinically as well as radiographically. The results recorded from both groups were compiled and put to statistical analysis. Chi-square test was used to compare the procedural errors (instrument separation, ledge formation, and perforation). In the present study, both hand Nitiflex and rotary K3XF showed ledge formation and instrument separation. Although ledge formation and instrument separation by rotary K3XF file system was less as compared to hand Nitiflex. No perforation was seen in both the instrument groups. Canal curvature played a significant role during the instrumentation of the curved canals. Procedural errors such as ledge formation and instrument separation by rotary K3XF file system were less as compared to hand Nitiflex.
González-López, Santiago; Martín-Altuve, Ernesto; Bolaños-Carmona, Victoria; Sánchez-Sánchez, Purificación; Rodríguez-Navarro, Alejandro
2013-10-01
To compare the percentage of collagen exposed in dentin root thirds after two irrigation protocols with manual or rotary instrumentation using two methacrylate resin-based sealers. Forty-eight single-root human teeth were prepared with manual (n = 24) or nickeltitanium ProFile rotary (n = 24) instrumentation, using 5% NaOCl between instruments and 5 ml 17% EDTA as final irrigant or 20% citric acid + 2% chlorhexidine (CHX) between instruments and as the final irrigant. RealSeal or EndoREZ were used as filling materials. One 1-mm slice per third was abraded and stained with Masson's trichrome method. Mean exposed collagen values were obtained in four areas from each section (at 60X magnification) and a complete factorial ANOVA was used to analyze the influence of the study variables. Non-parametric Mann-Whitney's test was used to compare groups. Differences with p < 0.05 were considered significant. A significantly higher percentage of collagen was exposed in all thirds with the use of the 20% citric acid + 2% CHX protocol with rotary vs manual instrumentation, but percent collagen exposed did not differ as a function of the filling material. After the 5% NaOCl + 17% EDTA protocol, the percentage of collagen exposed did not differ between rotary and manual instrumentation but was higher with the use of RealSeal. The highest percentage exposure of collagen was with 20% citric acid + 2% CHX using rotary instrumentation, regardless of the filling material.
Sterilization of rotary NiTi instruments within endodontic sponges.
Chan, H W A; Tan, K H; Dashper, S G; Reynolds, E C; Parashos, P
2015-08-17
To determine whether the following can be sterilized by autoclaving - endodontic sponges, rotary nickel-titanium (NiTi) instruments within endodontic sponges, and rotary NiTi instruments with rubber stoppers. Sixty-four samples of eight different endodontic sponges (n = 512) were placed into brain heart infusion broth (BHI) for 72 h. An aliquot of this was then spread onto horse blood agar and cultured aerobically and anaerobically to test sterility at purchase. Bacterial suspensions of Enterococcus faecalis, Porphyromonas gingivalis and Geobacillus stearothermophilus in BHI were used to contaminate sterile sponges and rotary NiTi instruments (with and without rubber stoppers) inserted into sponges. The various samples were autoclaved and then cultured aerobically and anaerobically. Success of sterilization was measured qualitatively as no growth. The experiment was repeated with clinically used rotary NiTi instruments (n = 512). All experiments were conducted in quadruplicate. No sponges on purchase had microbial growth when anaerobically cultured but some did when aerobically cultured. All autoclaved sponges and instruments (within or without sponges, and with or without rubber stoppers) were associated with no microbial growth. All nonautoclaved positive control samples showed microbial growth. Autoclaving was effective in the sterilization of sponges and endodontic instruments. Endodontic sponges should be autoclaved before clinical use. For clinical efficiency and cost-effectiveness, rotary NiTi instruments can be sterilized in endodontic sponges without removal of rubber stoppers. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Khanna, Rajesh; Handa, Aashish; Virk, Rupam Kaur; Ghai, Deepika; Handa, Rajni Sharma; Goel, Asim
2017-01-01
Background: The process of cleaning and shaping the canal is not an easy goal to obtain, as canal curvature played a significant role during the instrumentation of the curved canals. Aim: The present in vivo study was conducted to evaluate procedural errors during the preparation of curved root canals using hand Nitiflex and rotary K3XF instruments. Materials and Methods: Procedural errors such as ledge formation, instrument separation, and perforation (apical, furcal, strip) were determined in sixty patients, divided into two groups. In Group I, thirty teeth in thirty patients were prepared using hand Nitiflex system, and in Group II, thirty teeth in thirty patients were prepared using K3XF rotary system. The evaluation was done clinically as well as radiographically. The results recorded from both groups were compiled and put to statistical analysis. Statistical Analysis: Chi-square test was used to compare the procedural errors (instrument separation, ledge formation, and perforation). Results: In the present study, both hand Nitiflex and rotary K3XF showed ledge formation and instrument separation. Although ledge formation and instrument separation by rotary K3XF file system was less as compared to hand Nitiflex. No perforation was seen in both the instrument groups. Conclusion: Canal curvature played a significant role during the instrumentation of the curved canals. Procedural errors such as ledge formation and instrument separation by rotary K3XF file system were less as compared to hand Nitiflex. PMID:29042727
de Vasconcelos, Rafaela Andrade; Murphy, Sarah; Carvalho, Claudio Antonio Talge; Govindjee, Rajiv G; Govindjee, Sanjay; Peters, Ove A
2016-05-01
The purpose of this study was to evaluate the effect of 2 different temperatures (20°C and 37°C) on the cyclic fatigue life of rotary instruments and correlate the results with martensitic transformation temperatures. Contemporary nickel-titanium rotary instruments (n = 20 each and tip size #25, including Hyflex CM [Coltene, Cuyahoga Falls, OH], TRUShape [Dentsply Tulsa Dental Specialties, Tulsa, OK], Vortex Blue [Dentsply Tulsa Dental Specialties], and ProTaper Universal [Dentsply Tulsa Dental Specialties]) were tested for cyclic fatigue at room temperature (20°C ± 1°C) and at body temperature (37°C ± 1°C). Instruments were rotated until fracture occurred in a simulated canal with an angle curvature of about 60° and a radius curvature of 3 mm; the center of the curvature was 4.5 mm from the instrument tip. The number of cycles to fracture was measured. Phase transformation temperatures for 2 instruments of each brand were analyzed by differential scanning calorimetry. Data were analyzed using the t test and 1-way analysis of variance with the significance level set at 0.05. For the tested size and at 20°C, Hyflex CM showed the highest resistance to fracture; no significant difference was found between TRUShape and Vortex Blue, whereas ProTaper Universal showed the lowest resistance to fracture. At 37°C, resistance to fatigue fracture was significantly reduced, up to 85%, for the tested instruments (P < .001); at that temperature, Hyflex CM and Vortex Blue had similar and higher fatigue resistance compared with TRUShape and ProTaper Universal. Under the conditions of this study, using a novel testing design, immersion in water at simulated body temperature was associated with a marked decrease in the fatigue life of all rotary instruments tested. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Tang, Yadong; Shi, Jian; Li, Sisi; Wang, Li; Cayre, Yvon E.; Chen, Yong
2014-08-01
Capture of circulating tumor cells (CTCs) from peripheral blood of cancer patients has major implications for metastatic detection and therapy analyses. Here we demonstrated a microfluidic device for high efficiency and high purity capture of CTCs. The key novelty of this approach lies on the integration of a microfilter with conical-shaped holes and a micro-injector with cross-flow components for size dependent capture of tumor cells without significant retention of non-tumor cells. Under conditions of constant flow rate, tumor cells spiked into phosphate buffered saline could be recovered and then cultured for further analyses. When tumor cells were spiked in blood of healthy donors, they could also be recovered at high efficiency and high clearance efficiency of white blood cells. When the same device was used for clinical validation, CTCs could be detected in blood samples of cancer patients but not in that of healthy donors. Finally, the capture efficiency of tumor cells is cell-type dependent but the hole size of the filter should be more closely correlated to the nuclei size of the tumor cells. Together with the advantage of easy operation, low-cost and high potential of integration, this approach offers unprecedented opportunities for metastatic detection and cancer treatment monitoring.
Rotating Reverse-Osmosis for Water Purification
NASA Technical Reports Server (NTRS)
Lueptow, RIchard M.
2004-01-01
A new design for a water-filtering device combines rotating filtration with reverse osmosis to create a rotating reverse- osmosis system. Rotating filtration has been used for separating plasma from whole blood, while reverse osmosis has been used in purification of water and in some chemical processes. Reverse- osmosis membranes are vulnerable to concentration polarization a type of fouling in which the chemicals meant not to pass through the reverse-osmosis membranes accumulate very near the surfaces of the membranes. The combination of rotating filtration and reverse osmosis is intended to prevent concentration polarization and thereby increase the desired flux of filtered water while decreasing the likelihood of passage of undesired chemical species through the filter. Devices based on this concept could be useful in a variety of commercial applications, including purification and desalination of drinking water, purification of pharmaceutical process water, treatment of household and industrial wastewater, and treatment of industrial process water. A rotating filter consists of a cylindrical porous microfilter rotating within a stationary concentric cylindrical outer shell (see figure). The aqueous suspension enters one end of the annulus between the inner and outer cylinders. Filtrate passes through the rotating cylindrical microfilter and is removed via a hollow shaft. The concentrated suspension is removed at the end of the annulus opposite the end where the suspension entered.
A comparison of apical transportation between FlexMaster and Twisted Files rotary instruments.
Duran-Sindreu, Fernando; García, Marc; Olivieri, Juan Gonzalo; Mercadé, Montse; Morelló, Sergio; Roig, Miguel
2012-07-01
The aim of this study was to evaluate apical transportation in root canals after the use of Twisted Files (TF; SybronEndo, Orange, CA) and FlexMaster (VDW, Munich, Germany) #40/04 rotary files. A double-digital radiographic technique was used to compare apical transportation between the TF and FlexMaster systems. Each rotary system was used to instrument mesial canals from 80 extracted mandibular molars. The central axes of the file imaged before instrumentation (#15 K-file) and the master apical rotary file (#40/04) were superimposed digitally. AutoCAD 2008 (Autodesk Inc, San Rafael, CA) was used to measure apical transportation at 0.5 mm from the working length (WL). The data were analyzed using the Student's t test, and significance was set at P < .05. The mean amount of apical transportation at 0.5 mm from the WL was 0.17 ± 0.09 mm for the FlexMaster group and 0.19 ± 0.12 mm for the TF group. No statistically significant differences in apical transportation were found between the 2 groups. Under the conditions of the study, no statistically significant differences in apical transportation were observed between FlexMaster and TF rotary files. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Azar, Mohammad Reza; Safi, Laya; Nikaein, Afshin
2012-01-01
Background: Root canal cleaning is an important step in endodontic therapy. In order to develop better techniques, a new generation of endodontic instruments has been designed. The aim of this study was to compare the effectiveness of manual K-files (Mani Co, Tokyo, Japan) and two rotary systems–Mtwo (Dentsply-Maillefer, Ballaigues, Switzerland) and ProTaper (VDW, Munich, Germany)–for root canal preparation in primary molars. Materials and Methods: India ink was injected to 160 mesiobuccal and distal root canals of mandibular primary molars. The teeth were randomly divided into three experimental groups and one control group. In each experimental group, either manual instruments (K-files) or rotary instruments (Mtwo or ProTaper) were used to prepare root canals. After cleaning the canals and clearing the teeth, ink removal was evaluated with a stereomicroscope. Statistical analysis was done with Kruskal–Wallis and Friedman tests. Results: There were no significant differences in cleaning efficiency between manual and rotary instruments. Only ProTaper files performed significantly better in the coronal and middle thirds than in the apical third of the root canal. Conclusion: Manual K-files and the Mtwo and ProTaper rotary systems showed equally acceptable cleaning ability in primary molar root canals. PMID:22623929
Soi, Sonal; Yadav, Suman; Sharma, Sumeet; Sharma, Mohit
2015-01-01
Background and aims. During root canal preparation, debris extruded beyond the apical foramen may result in periapical inflammation and postoperative pain. To date no root canal preparation method has been developed that extrudes no periapical debris. The purpose of this study was to identify a system leading to minimal extrusion of debris from the apical foramen. The study was conducted to comparatively evaluate the amount of apical extrusion of debris during root canal preparation using hand ProTaper and GT rotary and RaCe rotary instruments using crown-down technique. Materials and methods. Ninety freshly extracted human single-rooted mandibular premolars were equally assigned to three groups (n=30). The root canals were instrumented using hand ProTaper, GT rotary and RaCe rotary systems. Debris and irrigant extruded from the apical foramen were collected into vials. The mean weight of the remaining debris was calculated for each group and subjected to statistical analysis. Results. ANOVA was used to compare the mean dry weights of the debris extruded in the three groups, followedby post hoc Tukey tests for multiple comparisons the between groups. Highly significant differences were found in the amount of debris extruded among all the groups (P<0.001). The ProTaper group exhibited the highest mean debris weight (0.8293±0.05433 mg) and the RaCe system exhibited the lowest mean debris weight (0.1280±0.01606 mg). Conclusion. All the systems tested resulted in apical extrusion of debris. However, the hand ProTaper files extruded a significantly higher amount of debris than GT and RaCe systems.
Soi, Sonal; Yadav, Suman; Sharma, Sumeet; Sharma, Mohit
2015-01-01
Background and aims. During root canal preparation, debris extruded beyond the apical foramen may result in periapical inflammation and postoperative pain. To date no root canal preparation method has been developed that extrudes no periapical debris. The purpose of this study was to identify a system leading to minimal extrusion of debris from the apical foramen. The study was conducted to comparatively evaluate the amount of apical extrusion of debris during root canal preparation using hand ProTaper and GT rotary and RaCe rotary instruments using crown-down technique. Materials and methods. Ninety freshly extracted human single-rooted mandibular premolars were equally assigned to three groups (n=30). The root canals were instrumented using hand ProTaper, GT rotary and RaCe rotary systems. Debris and irrigant extruded from the apical foramen were collected into vials. The mean weight of the remaining debris was calculated for each group and subjected to statistical analysis. Results. ANOVA was used to compare the mean dry weights of the debris extruded in the three groups, followedby post hoc Tukey tests for multiple comparisons the between groups. Highly significant differences were found in the amount of debris extruded among all the groups (P<0.001). The ProTaper group exhibited the highest mean debris weight (0.8293±0.05433 mg) and the RaCe system exhibited the lowest mean debris weight (0.1280±0.01606 mg). Conclusion. All the systems tested resulted in apical extrusion of debris. However, the hand ProTaper files extruded a significantly higher amount of debris than GT and RaCe systems. PMID:26697144
Influence of axial movement on fatigue of PROFILE* NI-TI rotary instruments: an in vitro evaluation
Avoaka, Marie-Chantal; Haïkel, Youssef
2010-01-01
The aim of this study was to evaluate the influence of the axial movement and the angle of curve (in degrees) on fatigue of nickel-titanium (Ni-Ti) ProFile’ rotary endodontic instruments. Ni-Ti ProFile’ rotary instruments (Maillefer SA, Ballaigues, Switzerland), 25 mm long in the range of ISO size 15 to 40 with two tapers (0.4 and 0.6) were evaluated. They are divided in two groups: the instruments with axial movement and those without axial movement. The system used to test the fatigue is maintained in mechanical conditions as close as possible to the clinical situation. The axial movement is in the order of 2mm in corono-apical direction with a frequency of 1Hz. The concave radii incorporating a notched V-form for guiding the instruments were: 5; 7,5 and 10 mm. The rotary system is mounted on an electric handpiece and rotated at 350 rpm speed as recommended by the manufacturers. The instruments are rotated until their separation, and the time, in seconds, is recorded. Statístícal evaluation is undertaken using a two-way t-test to identify significant differences between variables in the study (p <0,05). We found significant statistical difference (p<0,05) between Ni-Ti engine drive ProFile’ instruments incorporating an axial movement and the instruments without axial movement with the same radius of curvature, size and taper. The incorporation of the axial movement increases significantly the life-span of the ProFile’ rotary instruments. This should reduce the risk of the instrument separation during the endodontic treatment. PMID:20507289
Modification and performance evaluation of a mono-valve engine
NASA Astrophysics Data System (ADS)
Behrens, Justin W.
A four-stroke engine utilizing one tappet valve for both the intake and exhaust gas exchange processes has been built and evaluated. The engine operates under its own power, but has a reduced power capacity than the conventional 2-valve engine. The reduction in power is traced to higher than expected amounts of exhaust gases flowing back into the intake system. Design changes to the cylinder head will fix the back flow problems, but the future capacity of mono-valve engine technology cannot be estimated. The back flow of exhaust gases increases the exhaust gas recirculation (EGR) rate and deteriorates combustion. Intake pressure data shows the mono-valve engine requires an advanced intake valve closing (IVC) time to prevent back flow of charge air. A single actuation camshaft with advanced IVC was tested in the mono-valve engine, and was found to improve exhaust scavenging at TDC and nearly eliminated all charge air back flow at IVC. The optimum IVC timing is shown to be approximately 30 crank angle degrees after BDC. The mono-valve cylinder head utilizes a rotary valve positioned above the tappet valve. The open spaces inside the rotary valveand between the rotary valve and tappet valve represent a common volume that needs to be reduced in order to reduce the base EGR rate. Multiple rotary valve configurations were tested, and the size of the common volume was found to have no effect on back flow but a direct effect on the EGR rate and engine performance. The position of the rotary valve with respect to crank angle has a direct effect on the scavenging process. Optimum scavenging occurs when the intake port is opened just after TDC.
Werve, Michael E [Modesto, CA
2006-05-16
A system for inspecting a ceramic component. The ceramic component is positioned on a first rotary table. The first rotary table rotates the ceramic component. Light is directed toward the first rotary table and the rotating ceramic component. A detector is located on a second rotary table. The second rotary table is operably connected to the first rotary table and the rotating ceramic component. The second rotary table is used to move the detector at an angle to the first rotary table and the rotating ceramic component.
Ozone Technology for Pathogenic Bacteria of Shrimp (Vibrio sp.) Disinfection
NASA Astrophysics Data System (ADS)
Wulansarie, Ria; Dyah Pita Rengga, Wara; Rustamadji
2018-03-01
One of important marine commodities in Indonesia, shrimps are susceptible with Vibrio sp bacteria infection. That infection must be cleared. One of the technologies for disinfecting Vibrio sp. is ozone technology. In this research, Vibrio sp. is a pathogenic bacterium which infects Penaeus vannamei. Ozone technology is applied for threatening Vibrio sp. In this research, ozonation was performed in different pH. Those are neutral, acid (pH=4), and base (pH=9). The sample was water from shrimp embankment from Balai Besar Perikanan Budidaya Air Payau (BBPBAP) located in Jepara. That water was the habitat of Penaeus vannamei shrimp. The brand of ozonator used in this research was “AQUATIC”. The used ozonator in this research had 0,0325 g/hour concentration. The flow rate of sample used in this research was 2 L/minute. The ozonation process was performed in continuous system. A tank, pipe, pump, which was connected with microfilter, flowmeter and ozone generator were the main tools in this research. It used flowmeter and valve to set the flow rate scalable as desired. The first step was the insert of 5 L sample into the receptacle. Then, by using a pump, a sample supplied to the microfilter to be filtered and passed into the flow meter. The flow rate was set to 2 LPM. Furthermore, gas from ozonator passed to the flow for the disinfection of bacteria and then was recycled to the tank and the process run continuously. Samples of the results of ozonation were taken periodically from time 0, 3, 7, 12, 18, 24 to 30 minutes. The samples of the research were analyzed using Total Plate Count (TPC) test in BBPBAP Jepara to determine the number of Vibrio sp. bacteria. The result of this research was the optimal condition for pathogenic bacteria of shrimp (Vibrio sp.) ozonation was in neutral condition.
Tinoco, J M; De-Deus, G; Tinoco, E M B; Saavedra, F; Fidel, R A S; Sassone, L M
2014-06-01
To evaluate ex vivo, apical bacterial extrusion associated with two reciprocating single-file systems (WaveOne and Reciproc) compared with a conventional multifile rotary system (BioRace). Forty-five human single-rooted mandibular incisors were used. Endodontic access cavities were prepared, and root canals were contaminated with an Enterococcus faecalis suspension. Following incubation at 37 °C for thirty days, the contaminated teeth were divided into three groups of 15 specimens each (G1 - Reciproc, G2 - WaveOne and G3 - BioRace). Positive and negative controls consisted of 5 infected teeth and 3 uninfected incisors that were instrumented with one of the tested NiTi systems, respectively. Bacteria extruded from the apical foramen during instrumentation were collected into vials containing 0.9% NaCl. The microbiological samples were taken from the vials and incubated in brain heart agar medium for 24 h. The resulting bacterial titre, in colony-forming units (CFU) per mL, was determined, and these data were analysed by Wilcoxon matched-pairs signed rank test and Kruskal-Wallis H-test. The level of significance was set at α = 0.05. No significant difference was found in the number of CFU between the two reciprocating systems (P = 0.41). The conventional multifile rotary system group was associated with significantly higher CFU than both of the two reciprocating groups (P = 0.01). All instrumentation systems extruded bacteria beyond the foramen. However, both reciprocating single-file systems extruded fewer bacteria apically than the conventional multifile rotary system. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Update of the development on the new Audi NSU rotary engine generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
van Basshuysen, R.; Wilmers, G.
At AUDI NSU a new generation of rotary engines has been developed of which the significant layout parameters are outlined. The present status of development is characterized by a lean burn concept with fuel injection and an exhaust emission control system with catalytic converter. Test results indicate that the fuel economy ranges at the same level as comparable reciprocating engines. The future US-exhaust emission standards are kept below but in respect to the Japanese standards further reduction of NO/sub x/ is necessary. Endurance tests proving the durability of the exhaust emission control system have still to be performed.
Design of a CO2 Twin Rotary Compressor for a Heat Pump Water Heater
NASA Astrophysics Data System (ADS)
Ahn, Jong Min; Kim, Woo Young; Kim, Hyun Jin; Cho, Sung Oug; Seo, Jong Cheun
2010-06-01
For a CO2 heat pump water heater, one-stage twin rotary compressor has been designed. As a design tool, computer simulation program for the compressor performance has been made. Validation of the simulation program has been carried out for a bench model compressor in a compressor calorimeter. Cooling capacity and the compressor input power were reasonably well compared between the simulation and the calorimeter test. Good agreement on P-V diagram between the simulation and the test was also obtained. With this validated compressor simulation program, parametric study has been performed to arrive at optimum dimensions for the compression chamber.
Wellhead power production with a rotary separator turbine (RP 1196)
NASA Astrophysics Data System (ADS)
Cerini, D. J.; Record, J.
1982-12-01
A rotary-separator turbine was built with full flow capacity for a 500 F downhole temperature with a 850,000 lbm/hr production rate. The test system and results obtained in field tests are described. The preliminary design of a 10-megawatt wellhead power plant for the Roosevelt type resource is described. This system shows a specific power of .0013 kW hr per lbm, which is 20 percent greater than an optimized wellhead single stage flash plant. This is 26 percent greater than a central plant of 20 to 50 MW capacity when consideration is given to steam-gathering system pressure drop between the wells and central plant.
1989-01-11
Oct] 18 NEAR EAST & SOUTH ASIA INDIA Council for Medical Research Issues AIDS Report [THE SUNDA Y STATESMAN 13 Nov] 20 Rise in Malaria Deaths...54000026a Johannesburg THE STAR in English 2 Dec 88 p 2 [Article by Toni Younghusband, Medical Reporter] [Text] Tests at 33 schools have shown that more...Rotary Club, said: "Rotary provides those identified as having TB with one nutri- tional meal a day so that at the end of their medication they do not
Asthana, Geeta; Kapadwala, Marsrat I; Parmar, Girish J
2016-01-01
The aim of this study was to evaluate defects caused by torsional fatigue in used hand and rotary nickel-titanium (Ni-Ti) instruments by stereomicroscopic examination. One hundred five greater taper Ni-Ti instruments were used including Protaper universal hand (Dentsply Maillefer, Ballaigues, Switzerland), Protaper universal rotary (Dentsply Maillefer, Ballaigues, Switzerland), and Revo-S rotary (MicroMega, Besançon, France) files. Files were used on lower anterior teeth. After every use, the files were observed with both naked eyes and stereomicroscope at 20× magnification (Olympus, Shinjuku, Tokyo, Japan) to evaluate defects caused by torsional fatigue. Scoring was assigned to each file according to the degree of damage. The results were statistically analyzed using the Mann-Whitney U test and the Kruskal-Wallis test. A greater number of defects were seen under the stereomicroscope than on examining with naked eyes. However, the difference in methods of evaluation was not statistically significant. Revo-S files showed minimum defects, while Protaper universal hand showed maximum defects. The intergroup comparison of defects showed that the bend in Protaper universal hand instruments was statistically significant. Visible defects in Ni-Ti files due to torsional fatigue were seen by naked eyes as well as by stereomicroscope. This study emphasizes that all the files should be observed before and after every instrument cycle to minimize the risk of separation.
Proposed design modifications to reduce risk of operating rotary field mowers.
White, K L; Wells, L G; Shearer, S A; Piercy, L R
2000-11-01
The primary objective of this project was to reduce risk of injury associated with operating a rotary mower driven by a tractor power take-off (PTO) by developing and evaluating design improvements and determining their economic feasibility. Researchers have concluded that alteration of machinery design has a greater impact on the reduction of accidents than safety training. Implementation of an Operator Presence Sensing System (OPSS) and removal of the PTO are the two injury-reducing, engineering modifications evaluated by this research. Hydraulic power allows this to occur by providing dynamic braking, few moving parts (removal of the PTO), and controllable power. A hydraulic circuit was developed to power the mower and to enable an OPSS. Tractor hydraulics were simulated using a hydraulic training bench. Two mower configurations were tested: 6.55 cm3 rev(-1) (0.4 in.3 rev(-1)) displacement motor with a 0.748 kg blade and 47.5 cm3 rev(-1) (2.9 in.3 rev(-1)) displacement motor with a 9.4 kg blade. A PTO-driven rotary mower was not used to test the circuit due to spatial and safety limitations of the hydraulic training bench. Results from the first mower configuration verified the concepts behind the hydraulic circuit. The second configuration verified the OPSS and indicated the applicability of the circuit to a rotary mower.
NASA Astrophysics Data System (ADS)
Marchesan, Melissa A.; Geurisoli, Danilo M. Z.; Brugnera, Aldo, Jr.; Barbin, Eduardo L.; Pecora, Jesus D.
2002-06-01
The present study examined root canal cleaning, using the optic microscope, after rotary instrumentation with ProFile.04 with or without laser application with different output energies. Cleaning and shaping can be accomplished manually, with ultra-sonic and sub-sonic devices, with rotary instruments and recently, increasing development in laser radiation has shown promising results for disinfection and smear layer removal. In this study, 30 palatal maxillary molar roots were examined using an optic microscope after rotary instrumentation with ProFile .04 with or without Er:YAG laser application (KaVo KeyLaser II, Germany) with different output energies (2940 nm, 15 Hz, 300 pulses, 500 milli-sec duration, 42 J, 140 mJ showed on the display- input, 61 mJ at fiberoptic tip-output and 140 mJ showed on the display-input and 51 mJ at fiberoptic tip-output). Statistical analysis showed no statistical differences between the tested treatments (ANOVA, p>0.05). ANOVA also showed a statistically significant difference (p<0.01) between the root canal thirds, indicating that the middle third had less debris than the apical third. We conclude that: 1) none of the tested treatments led to totally cleaned root canals; 2) all treatments removed debris similarly, 3) the middle third had less debris than the apical third; 4) variation in output energy did not increase cleaning.
Rotary Valve & Beamline Highlights for Fiscal Year 2017
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fitsos, P
This Fiscal Year (FY) work was divided between continued testing and characterization work of the Rotary Valve (RV) and mechanical engineering support for the beamline hardware stands. This configuration is more like the final setup with the accelerator firing deuterons down the evacuated beamline toward the RV for interaction with the deuterium and neutron production. The beamline cells were part of an experiment to reduce the impact that RV gas would have on the beamline vacuum. This work will be reported separately from this report. Previous testing had been with the beamline at atmospheric pressure and now the goal wasmore » to get test results of the RV with it connected to a beamline that’s running at some level of vacuum.« less
Preliminary results on performance testing of a turbocharged rotary combustion engine
NASA Technical Reports Server (NTRS)
Meng, P. R.; Rice, W. J.; Schock, H. J.; Pringle, D. P.
1982-01-01
The performance of a turbocharged rotary engine at power levels above 75 kW (100 hp) was studied. A twin rotor turbocharged Mazda engine was tested at speeds of 3000 to 6000 rpm and boost pressures to 7 psi. The NASA developed combustion diagnostic instrumentation was used to quantify indicated and pumping mean effect pressures, peak pressure, and face to face variability on a cycle by cycle basis. Results of this testing showed that a 5900 rpm a 36 percent increase in power was obtained by operating the engine in the turbocharged configuration. When operating with lean carburetor jets at 105 hp (78.3 kW) and 4000 rpm, a brake specific fuel consumption of 0.45 lbm/lb-hr was measured.
Bürklein, Sebastian; Schäfer, Edgar
2012-06-01
The purpose of this in vitro study was to assess the amount of apically extruded debris using rotary and reciprocating nickel-titanium instrumentation systems. Eighty human mandibular central incisors were randomly assigned to 4 groups (n = 20 teeth per group). The root canals were instrumented according to the manufacturers' instructions using the 2 reciprocating single-file systems Reciproc (VDW, Munich, Germany) and WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) and the 2 full-sequence rotary Mtwo (VDW, Munich, Germany) and ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) instruments. Bidistilled water was used as irrigant. The apically extruded debris was collected in preweighted glass vials using the Myers and Montgomery method. After drying, the mean weight of debris was assessed with a microbalance and statistically analyzed using analysis of variance and the post hoc Student-Newman-Keuls test. The time required to prepare the canals with the different instruments was also recorded. The reciprocating files produced significantly more debris compared with both rotary systems (P < .05). Although no statistically significant difference was obtained between the 2 rotary instruments (P > .05), the reciprocating single-file system Reciproc produced significantly more debris compared with all other instruments (P < .05). Instrumentation was significantly faster using Reciproc than with all other instrument (P < .05). Under the condition of this study, all systems caused apical debris extrusion. Full-sequence rotary instrumentation was associated with less debris extrusion compared with the use of reciprocating single-file systems. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Dust emissions created by low-level rotary-winged aircraft flight over desert surfaces
NASA Astrophysics Data System (ADS)
Gillies, J. A.; Etyemezian, V.; Kuhns, H.; McAlpine, J. D.; King, J.; Uppapalli, S.; Nikolich, G.; Engelbrecht, J.
2010-03-01
There is a dearth of information on dust emissions from sources that are unique to U.S. Department of Defense testing and training activities. Dust emissions of PM 10 and PM 2.5 from low-level rotary-winged aircraft travelling (rotor-blade ≈7 m above ground level) over two types of desert surfaces (i.e., relatively undisturbed desert pavement and disturbed desert soil surface) were characterized at the Yuma Proving Ground (Yuma, AZ) in May 2007. Fugitive emissions are created by the shear stress of the outflow of high speed air created by the rotor-blade. The strength of the emissions was observed to scale primarily as a function of forward travel speed of the aircraft. Speed affects dust emissions in two ways: 1) as speed increases, peak shear stress at the soil surface was observed to decline proportionally, and 2) as the helicopter's forward speed increases its residence time over any location on the surface diminishes, so the time the downward rotor-generated flow is acting upon that surface must also decrease. The state of the surface over which the travel occurs also affects the scale of the emissions. The disturbed desert test surface produced approximately an order of magnitude greater emission than the undisturbed surface. Based on the measured emission rates for the test aircraft and the established scaling relationships, a rotary-winged aircraft similar to the test aircraft traveling 30 km h -1 over the disturbed surface would need to travel 4 km to produce emissions equivalent to one kilometer of travel by a light wheeled military vehicle also traveling at 30 km h -1 on an unpaved road. As rotary-winged aircraft activity is substantially less than that of off-road vehicle military testing and training activities it is likely that this source is small compared to emissions created by ground-based vehicle movements.
Arias, Ana; Paqué, Frank; Shyn, Stephanie; Murphy, Sarah; Peters, Ove A
2018-04-01
The purpose of this study was to assess the geometry of non-round root canals after preparation with TRUShape (a novel instrument with s-shaped longitudinal design) in comparison to conventional rotary instrumentation using micro-computed tomography. Twenty distal root canals of mandibular molars were randomly distributed in two groups to be shaped with either TRUShape or Vortex rotaries. Percentages of unprepared surface and volume of dentin removal for the entire canal and for the apical 4 mm were calculated. Canal transportation and the structure model index (SMI) were assessed. Data were compared with Student t-tests. Shaping with both techniques resulted in similar prepared surface and volume of dentin removed, as well as the extent of canal transportation. The SMI shape factor was significantly lower for TRUShape preparations (P = 0.04) suggesting less rounding during rotary preparation. Although both instruments were suitable for the preparation of oval canals, TRUShape appeared to better conform to the original ribbon-shaped anatomy. © 2017 Australian Society of Endodontology Inc.
Comparison of apical and coronal extrusions using reciprocating and rotary instrumentation systems.
Lu, Yan; Chen, Min; Qiao, Feng; Wu, Ligeng
2015-08-07
The aim of this study was to compare the apical and coronal extrusions by using two reciprocating and two rotary instrumentation systems. Eighty extracted human single-rooted anterior teeth were randomly assigned to four groups. Four different root canal instrumentation systems were used according to the manufacturers instructions, including two reciprocating single-file systems, Reciproc and WaveOne, and two full-sequence rotary BLX and ProTaper instruments. Debris collected from the coronal by the instruments and apical extrusions were quantified respectively. After drying the collections, the mean weight of debris collected from apical and coronal extrusions was assessed using an electronic balance and analyzed using the Kruskal-Wallis H and Mann-Whitney U tests. Statistically significant differences in the apical extrusion were observed among the four groups. Reciproc and WaveOne instruments produced significantly less debris than BLX and ProTaper instruments (P < 0.05). All of the systems produced apical extrusion of debris. However, reciprocating single-file systems produced less apical extrusion than full-sequence rotary systems. No relationship was observed between apical and coronal extrusions.
Multi-fuel rotary engine for general aviation aircraft
NASA Technical Reports Server (NTRS)
Jones, C.; Ellis, D. R.; Meng, P. R.
1983-01-01
Design studies of advanced multifuel general aviation and commuter aircraft rotary stratified charge engines are summarized. Conceptual design studies were performed at two levels of technology, an advanced general aviation engines sized to provide 186/250 shaft kW/hp under cruise conditions at 7620 (25,000 m/ft) altitude. A follow on study extended the results to larger (2500 hp max.) engine sizes suitable for applications such as commuter transports and helicopters. The study engine designs were derived from relevant engine development background including both prior and recent engine test results using direct injected unthrottled rotary engine technology. Aircraft studies, using these resultant growth engines, define anticipated system effects of the performance and power density improvements for both single engine and twin engine airplanes. The calculated results indicate superior system performance and 27 to 33 percent fuel economy improvement for the rotary engine airplanes as compared to equivalent airframe concept designs with current baseline engines. The research and technology activities required to attain the projected engine performance levels are also discussed. Previously announced in STAR as N83-18910
Bae, Jin-Hyuk; Yi, Jaeyoung; Kim, Sungtae; Shim, June-Sung; Lee, Keun-Woo
2014-01-01
Cutting efficiency is one of the most important factors to consider when a specific dental diamond rotary instrument is selected. However, the selection of a dental diamond rotary instrument is based on clinical experience rather than any scientific evidence. The purpose of this study was to identify how the cutting efficiency of different types of dental diamond rotary instrument changed with repeated cuts and disinfection. Four types of diamond rotary instrument from 2 dental manufacturers (Shofu, Jin Dental) were investigated with a high-speed air-turbine handpiece. The groups were as follows: S cham group (n=10): chamfer design from Shofu; J cham group (n=10): chamfer design from Jin Dental; S thin group (n=10): thin tapered design from Shofu; J thin group (n=10): thin tapered design from Jin Dental. Changes in the cutting efficiency of diamond rotary instruments on glass ceramic blocks were measured after repeated cuts. Changes in cutting efficiency also were measured for 30 diamond rotary instruments, the same type as those used in group J cham after disinfection with ethylene oxide gas, immersion in solution, or autoclaving. One-way ANOVA, 2-way ANOVA, and repeated-measures ANOVA were used to identify differences in cutting efficiency, in total cutting efficiency, and change trend in cutting efficiency (α=.05). The Tukey honestly significant difference method was used for the post hoc tests. The principal metal components of the diamond rotary instruments were detected with x-ray spectrometry. The mean (standard deviation [SD]) total cutting efficiency after 10 cuts in the 4 groups was in the following order: J cham group (0.210 ± 0.064 g/min) > S cham group (0.170 ± 0.064 g/min) > J thin group (0.130 ± 0.042 g/min) > S thin group (0.010 ± 0.040 g/min) (P<.05).The decrease in the cutting efficiency was greatest after the first cut. The cutting efficiency was not influenced by repeated disinfection. The cutting efficiencies of diamond rotary instruments with different designs and particle sizes showed a decreasing trend after repeated cuts but did not show any change after various disinfecting procedures. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Improvements for rotary viscous dampers used in spacecraft deployment mechanisms
NASA Technical Reports Server (NTRS)
Stewart, Alphonso; Powers, Charles; Lyons, Ron
1998-01-01
During component level thermal-vacuum deployment testing of eight rotary viscous dampers for the Tropical Rainfall Measuring Mission (TRMM) satellite, all the dampers failed to provide damping during a region of the deployment. Radiographic examination showed that air in the damping fluid caused the undamped motion when the dampers were operated in a vacuum environment. Improvements in the procedure used to fill the dampers with damping fluid, the installation of a Viton vacuum seal in the damper cover, and improved screening techniques eliminated the problem.
Kakkar, Pooja; Vats, Asit
2015-01-01
Objective: The objective of this study was to compare the smear layer formed on root canal walls during canal preparation of extracted human teeth by Twisted, Mtwo, and ProTaper rotary nickel titanium instruments. Materials and Methods: Sixty single rooted human premolar teeth with root curvature <250 were selected and randomly divided into three Groups (n= 20 teeth per Group). Three types of rotary nickel titanium instruments were used, Twisted (SybronEndo, Orange, CA, USA), Mtwo (VDW, Munich, Germany) and ProTaper (Dentsply Maillefer, Ballaigues, Switzerland) according to manufacturer’s instructions to instrument the root canals. Irrigation for all groups was performed after each instrument change with 3ml of 3% sodium hypochlorite followed by Glyde (File Prep, Dentsply, Maillefer, Ballaigues, Switzerland) as chelator paste and lubricant. Three different areas (coronal, middle and apical thirds) of the root canal were evaluated using scanning electron microscopy (SEM). The canal wall of each sample was assessed and compared using a predefined scale for the presence or absence of smear layer. Data were analysed statistically using ANOVA and Tukey HSD test Results: All three groups showed statistically significant more smear layer in the apical thirds of the canal as compared to the coronal and middle thirds (p<0.001). Mtwo rotary file system produced significantly less smear layer (p<0.001) compared to Twisted and ProTaper rotary instruments in the apical portion. Twisted Files resulted in less smear layer formation in the apical thirds of the canal compared to ProTaper rotary instruments but were statistically insignificant. Conclusion: Completely clean root canals were not found after instrumentation with any of the three instruments. Under the confines of this study Mtwo instruments produced significantly cleaner dentin wall surfaces throughout the canal length in comparison to Twisted and ProTaper rotary files. Twisted Files proved to be comparable to ProTaper rotary instruments with respect to canal cleanliness in the apical thirds of the root canal. PMID:25954704
Development of a Piezoelectric Rotary Hammer Drill
NASA Technical Reports Server (NTRS)
Domm, Lukas N.
2011-01-01
The Piezoelectric Rotary Hammer Drill is designed to core through rock using a combination of rotation and high frequency hammering powered by a single piezoelectric actuator. It is designed as a low axial preload, low mass, and low power device for sample acquisition on future missions to extraterrestrial bodies. The purpose of this internship is to develop and test a prototype of the Piezoelectric Rotary Hammer Drill in order to verify the use of a horn with helical or angled cuts as a hammering and torque inducing mechanism. Through an iterative design process using models in ANSYS Finite Element software and a Mason's Equivalent Circuit model in MATLAB, a horn design was chosen for fabrication based on the predicted horn tip motion, electromechanical coupling, and neutral plane location. The design was then machined and a test bed assembled. The completed prototype has proven that a single piezoelectric actuator can be used to produce both rotation and hammering in a drill string through the use of a torque inducing horn. Final data results include bit rotation produced versus input power, and best drilling rate achieved with the prototype.
Shivanand, Sunita; Patil, Chetan R; Thangala, Venugopal; Kumar, Pabbati Ravi; Sachdeva, Jyoti; Krishna, Akash
2013-05-01
To evaluate and compare the efficacy, cleaning ability of hand and two rotary systems in root canal retreatment. Sixty extracted premolars were retreated with following systems: Group -ProTaper Universal retreatment files, Group 2-ProFile system, Group 3-H-file. Specimens were split longitudinally and amount of remaining gutta-percha on the canal walls was assessed using direct visual scoring with the aid of stereomicroscope. Results were statistically analyzed using ANOVA test. Completely clean root canal walls were not achieved with any of the techniques investigated. However, all three systems proved to be effective for gutta-percha removal. Significant difference was found between ProTaper universal retreatment file and H-file, and also between ProFile and H-file. Under the conditions of the present study, ProTaper Universal retreatment files left significantly less guttapercha and sealer than ProFile and H-file. Rotary systems in combination with gutta-percha solvents can perform superiorly as compared to the time tested traditional hand instrumentation in root canal retreatment.
Mesgouez, C; Rilliard, F; Matossian, L; Nassiri, K; Mandel, E
2003-03-01
The aim of this study was to determine the influence of operator experience on the time needed for canal preparation when using a rotary nickel-titanium (Ni-Ti) system. A total of 100 simulated curved canals in resin blocks were used. Four operators prepared a total of 25 canals each. The operators included practitioners with prior experience of the preparation technique, and practitioners with no experience. The working length for each instrument was precisely predetermined. All canals were instrumented with rotary Ni-Ti ProFile Variable Taper Series 29 engine-driven instruments using a high-torque handpiece (Maillefer, Ballaigues, Switzerland). The time taken to prepare each canal was recorded. Significant differences between the operators were analysed using the Student's t-test and the Kruskall-Wallis and Dunn nonparametric tests. Comparison of canal preparation times demonstrated a statistically significant difference between the four operators (P < 0.001). In the inexperienced group, a significant linear regression between canal number and preparation time occurred. Time required for canal preparation was inversely related to operator experience.
Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, Emg
2017-09-01
Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary teeth.
NASA Technical Reports Server (NTRS)
Mulcay, W. J.; Rose, R. A.
1980-01-01
Aerodynamic characteristics obtained in a helical flow environment utilizing a rotary balance located in the Langley spin tunnel are presented in plotted form for a 1/6 scale, single engine, low wing, general aviation model (model C). The configurations tested included the basic airplane and control deflections, wing leading edge and fuselage modification devices, tail designs and airplane components. Data are presented without analysis for an angle of attack range of 8 deg to 90 deg and clockwise and counter clockwise rotations covering an omega b/2v range from 0 to .9.
Peters, O A; Gluskin, A K; Weiss, R A; Han, J T
2012-11-01
To determine several properties including torsional and fatigue limits, as well as torque during canal preparation, of Hyflex, a rotary instrument manufactured from so-called controlled memory nickel-titanium alloy. The instruments were tested in vitro using a special torque bench that permits both stationary torque tests according to ISO3630-1 and fatigue limit determination, as well as measurement of torque (in Ncm) and apical force (in N) during canal preparation. Fatigue limit (in numbers of cycles to failure) was determined in a 90°, 5 mm radius block-and-rod assembly. Simulated canals in plastic blocks were prepared using both a manufacturer-recommended single-length technique as well as a generic crown-down approach. anova with Bonferroni post hoc procedures was used for statistical analysis. Torque at failure ranged from 0.47 to 1.38 Ncm, with significant differences between instrument sizes (P < 0.0001). Fatigue life ranged from 260 to 2565, with the shortest and longest lifespan for instruments size 20, .04 taper and size 25, .08 taper, respectively. Torque during canal preparation was significantly higher for small instruments used in the single-length technique but lower for the size 40, .04 taper, compared to a crown-down approach. No instrument fractured; 82% of the instruments used were plastically deformed; however, only 37% of these remained deformed after a sterilization cycle. Hyflex rotary instruments are bendable and flexible and have similar torsional resistance compared to instruments made of conventional NiTi. Fatigue resistance is much higher, and torque during preparation is less, compared to other rotary instruments tested previously under similar conditions. © 2012 International Endodontic Journal.
Martinho, Frederico C; Freitas, Lilian F; Nascimento, Gustavo G; Fernandes, Aleteia M; Leite, Fabio R M; Gomes, Ana P M; Camões, Izabel C G
2015-07-01
This clinical study was conducted to compare the effectiveness of single-file reciprocating systems and rotary systems in removing endotoxins and cultivable bacteria in endodontic retreatment. Thirty endodontically treated teeth with post-treatment apical periodontitis were selected. The specimens were divided into three groups according to the system used: WaveOne (n = 10), Reciproc instrument (n = 10), and ProTaper Universal Retreatment system (n = 10). Samples were collected before and after chemomechanical preparation. The irrigation was performed by using 2.5% sodium hypochlorite. A chromogenic limulus amebocyte lysate assay test was used to quantify endotoxins. Culture techniques were used to determine bacterial colony-forming unit counts. At baseline, endotoxins and cultivable bacteria were recovered from 100% of the root canal samples in a median value of 5.84 EU/mL and 4.98 × 10(3) CFU/mL, respectively. After CMP, no differences were found in the median percentage values of endotoxin reduction achieved with reciprocating systems-WaveOne [94.11%] and Reciproc [93.29%] and with rotary systems-ProTaper [94.98%] (P > 0.05). Both single-file reciprocating systems [WaveOne (98.27%) and Reciproc (99.54%)] and rotary system [ProTaper (98.73%)] were effective in reducing bacterial load (P > 0.05). Moreover, no differences were found among the systems tested. The Reciproc and WaveOne reciprocating systems were as effective as the ProTaper system for removal of endotoxins and bacteria in endodontic retreatment. All systems tested were effective to remove cultivable bacteria and endotoxin in endodontic retreatment. As no differences among systems were observed, it is possible to suggest that clinicians should choose the preferred technique to perform endodontic.
Vadhana, Sekar; SaravanaKarthikeyan, Balasubramanian; Nandini, Suresh; Velmurugan, Natanasabapathy
2014-07-01
The purpose of this study was to evaluate and compare the cyclic fatigue resistance of RaCe (FKG Dentaire, La Chaux-de-Fonds, Switzerland) and Mtwo (VDW, Munich, Germany) rotary files in continuous rotation and reciprocating motion. A total of 60 new rotary Mtwo and RaCe files (ISO size = 25, taper = 0.06, length = 25 mm) were selected and randomly divided into 4 groups (n = 15 each): Mtc (Mtwo NiTi files in continuous rotation), Rc (RaCe NiTi files in continuous rotation), Mtr (Mtwo NiTi files in reciprocating motion), and Rr (RaCe NiTi files in reciprocating motion). A cyclic fatigue testing device was fabricated with a 60° angle of curvature and a 5-mm radius. All instruments were rotated or reciprocated until fracture occurred. The time taken for each instrument to fracture and the length of the broken fragments were recorded. All the fractured files were analyzed under a scanning electron microscope to detect the mode of fracture. The Kolmogorov-Smirnov test was used to assess the normality of samples distribution, and statistical analysis was performed using the independent sample t test. The time taken for the instruments of the Mtr and Rr groups to fail under cyclic loading was significantly longer compared with the Mtc and Rc groups (P < .001). Scanning electron microscopic observations showed that the instruments of all groups had undergone a ductile mode of fracture. The length of the fractured segments was between 5 and 6 mm, which was not statistically significant among the experimental groups. Mtwo and RaCe rotary instruments showed a significantly higher cyclic fatigue resistance in reciprocating motion compared with continuous rotation motion. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
TRACT 2 Frame Drop Test AT NASA Langley Research Center's Landin
2014-05-09
(Tract)2 Transport Rotorcraft Airframe Crash Testbed; Full Frame Drop Test: rotary wing crash worthiness, impact research at NASA Langley Research Center's Landing and Impact Research (LandIR) Facility Building 1297
Computational experience with a three-dimensional rotary engine combustion model
NASA Astrophysics Data System (ADS)
Raju, M. S.; Willis, E. A.
1990-04-01
A new computer code was developed to analyze the chemically reactive flow and spray combustion processes occurring inside a stratified-charge rotary engine. Mathematical and numerical details of the new code were recently described by the present authors. The results are presented of limited, initial computational trials as a first step in a long-term assessment/validation process. The engine configuration studied was chosen to approximate existing rotary engine flow visualization and hot firing test rigs. Typical results include: (1) pressure and temperature histories, (2) torque generated by the nonuniform pressure distribution within the chamber, (3) energy release rates, and (4) various flow-related phenomena. These are discussed and compared with other predictions reported in the literature. The adequacy or need for improvement in the spray/combustion models and the need for incorporating an appropriate turbulence model are also discussed.
Computational experience with a three-dimensional rotary engine combustion model
NASA Technical Reports Server (NTRS)
Raju, M. S.; Willis, E. A.
1990-01-01
A new computer code was developed to analyze the chemically reactive flow and spray combustion processes occurring inside a stratified-charge rotary engine. Mathematical and numerical details of the new code were recently described by the present authors. The results are presented of limited, initial computational trials as a first step in a long-term assessment/validation process. The engine configuration studied was chosen to approximate existing rotary engine flow visualization and hot firing test rigs. Typical results include: (1) pressure and temperature histories, (2) torque generated by the nonuniform pressure distribution within the chamber, (3) energy release rates, and (4) various flow-related phenomena. These are discussed and compared with other predictions reported in the literature. The adequacy or need for improvement in the spray/combustion models and the need for incorporating an appropriate turbulence model are also discussed.
de Almeida, Bernardo Corrêa; Ormiga, Fabíola; de Araújo, Marcos César Pimenta; Lopes, Ricardo Tadeu; Lima, Inayá Corrêa Barbosa; dos Santos, Bernardo Camargo; Gusman, Heloisa
2015-12-01
The aim of this study was to make a 3-dimensional comparison of the canal transportation and changes in apical geometry using micro-computed tomographic imaging after canal preparation with K3 (SybronEndo, Orange, CA) and K3XF (SybronEndo) file systems. Twenty-eight mandibular molars were randomly divided into 2 groups according to the rotary system used in instrumentation: K3 or K3XF. The specimens were scanned by micro-computed tomographic imaging before and after instrumentation. Images before and after instrumentation from each group were compared with regard to canal volume, surface area, and structure model index (SMI) (paired t test, P < .05). After instrumentation, the canals from each group were compared regarding the changes in volume, surface area, SMI, and canal transportation in the last 4 apical mm (t test, P < .05). Instrumentation with the 2 rotary systems significantly changed the canal volume, surface area, and SMI (P < .05). There were no significant differences between instrument types concerning these parameters (P > .05). There were no significant differences between the 2 groups with regard to canal transportation in the last 4 apical mm (P > .05). Both rotary systems showed adequate canal preparations with reduced values of canal transportation. Heat treatment did not influence changes in root canal geometry in the apical region. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Asthana, Geeta; Kapadwala, Marsrat I.; Parmar, Girish J.
2016-01-01
Objective: The aim of this study was to evaluate defects caused by torsional fatigue in used hand and rotary nickel-titanium (Ni-Ti) instruments by stereomicroscopic examination. Materials and Methods: One hundred five greater taper Ni-Ti instruments were used including Protaper universal hand (Dentsply Maillefer, Ballaigues, Switzerland), Protaper universal rotary (Dentsply Maillefer, Ballaigues, Switzerland), and Revo-S rotary (MicroMega, Besançon, France) files. Files were used on lower anterior teeth. After every use, the files were observed with both naked eyes and stereomicroscope at 20× magnification (Olympus, Shinjuku, Tokyo, Japan) to evaluate defects caused by torsional fatigue. Scoring was assigned to each file according to the degree of damage. Statistics: The results were statistically analyzed using the Mann-Whitney U test and the Kruskal-Wallis test. Results: A greater number of defects were seen under the stereomicroscope than on examining with naked eyes. However, the difference in methods of evaluation was not statistically significant. Revo-S files showed minimum defects, while Protaper universal hand showed maximum defects. The intergroup comparison of defects showed that the bend in Protaper universal hand instruments was statistically significant. Conclusion: Visible defects in Ni-Ti files due to torsional fatigue were seen by naked eyes as well as by stereomicroscope. This study emphasizes that all the files should be observed before and after every instrument cycle to minimize the risk of separation. PMID:27099415
DOT National Transportation Integrated Search
1967-01-01
The paper provides information that angular acceleration tests of the vestibular system transcend clinical caloric tests in revealing adaptation to angular accelerations as experienced in rotary motions, including flight situations. The caloric test ...
Alves, Vanessa de Oliveira; Bueno, Carlos Eduardo da Silveira; Cunha, Rodrigo Sanches; Pinheiro, Sérgio Luiz; Fontana, Carlos Eduardo; de Martin, Alexandre Sigrist
2012-01-01
Nickel-titanium rotary instruments reduce procedural errors and the time required to finish root canal preparation. The goal of this study was to evaluate the occurrences of apical transportation and canal aberrations produced with different instruments used to create a glide path in the preparation of curved root canals, namely manual K-files (Dentsply Maillefer, Ballaigues, Switzerland) and PathFile (Dentsply Maillefer) and Mtwo (Sweden and Martina, Padua, Italy) nickel-titanium rotary files. The mesial canals of 45 mandibular first and second molars (with curvature angles between 25° and 35°) were selected for this study. The specimens were divided randomly into 3 groups with 15 canals each, and canal preparation was performed by an endodontist using #10-15-20 K-type stainless steel manual files (group M), #13-16-19 PathFile rotary instruments (group PF), and #10-15-20 Mtwo rotary instruments (group MT). The double digital radiograph technique was used, pre- and postinstrumentation, to assess whether apical transportation and/or aberration in root canal morphology occurred. The initial and final images of the central axis of the canals were compared by superimposition through computerized analysis and with the aid of magnification. The specimens were analyzed by 3 evaluators, whose calibration was checked using the Kendall agreement test. No apical transportation or aberration in root canal morphology occurred in any of the teeth; therefore, no statistical analysis was conducted. Neither the manual instruments nor the PathFile or Mtwo rotary instruments used to create a glide path had any influence on the occurrence of apical transportation or produced any canal aberration. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Parashos, P; Messer, H H
2004-04-01
To ascertain the extent of the adoption and use of rotary nickel-titanium (NiTi) instruments and techniques in general dental practice and specialist endodontic practice in Australia in 2001. A questionnaire survey comprising 43 questions was developed by first creating questions, then pilot testing with 10 postgraduate students in endodontics, followed by a final revision. The final series of questions covered demographics, patterns of rotary NiTi usage, issues associated with NiTi usage and training in NiTi use. The sampling frame was 908, comprising 64 endodontists and 844 general dentists. The overall response rate was 87%. Rotary NiTi instruments were used by 22% of general dentists and 64% of endodontists. The two main reasons for not using rotary NiTi were 'no perceived advantage' and 'too fragile'. Instrument fracture had been experienced by 74% of respondents, and 72% of these had fractured one to five files for the two main perceived reasons of 'excessive pressure on the file' and 'over-usage'. The next two most common problems encountered were 'binding' (53%) and 'ledging' (45%). Very high proportions of positive experiences were noted. Most respondents (73%) had attended one or more continuing education courses, most of which were provided by dental supply companies (64%). The results indicate a sensible and responsible approach to the incorporation of rotary NiTi instruments and techniques into root canal treatment. Dentists were aware of the limitations of the new technology, but were taking steps to become familiar with the properties and behaviour of the instruments. Instrument fracture was common, but it was of low frequency and did not deter dentists from using the technology.
Peters, Ove A; Kappeler, Stefan; Bucher, Willi; Barbakow, Fred
2002-04-01
An increasing number of engine-driven rotary systems are marketed to shape root canals. Although these systems may improve the quality of canal preparations, the risk for instrument fracture is also increased. Unfortunately, the stresses generated in rotary instruments when shaping curved root canals have not been adequately studied. Consequently, the aim of an ongoing project was to develop a measurement platform that could more accurately detail physical parameters generated in a simulated clinical situation. Such a platform was constructed by fitting a torque-measuring device between the rotating endodontic instrument and the motor driving it. Apically directed force and instrument insertion depth were also recorded. Additional devices were constructed to assess cyclic fatigue and static fracture loads. The current pilot study evaluated GT rotary instruments during the shaping of curved canals in plastic blocks as well as "ISO 3630-1 torque to fracture" and number of rotations required for fatigue fracture. Results indicated that torques in excess of 40 Nmm were generated by rotary GT-Files, a significantly higher figure than static fracture loads (less than 13 Nmm for the size 20. 12 GT-File). Furthermore, the number of rotations needed to shape simulated canals with a 5 mm radius of curvature in plastic blocks was 10 times lower than the number of rotations needed to fracture instruments in a "cyclic fatigue test". Apical forces were always greater than 1 N, and in some specimens, scores of 8 N or more were recorded. Further studies are required using extracted natural teeth, with their wide anatomical variation, in order to reduce the incidence of fracture of rotary instruments. In this way, the clinical potential of engine-driven rotary instruments to safely prepare curved canals can be fully appreciated.
NASA Astrophysics Data System (ADS)
Cross, Jack; Schneider, John; Cariani, Pete
2013-05-01
Sierra Nevada Corporation (SNC) has developed rotary and fixed wing millimeter wave radar enhanced vision systems. The Helicopter Autonomous Landing System (HALS) is a rotary-wing enhanced vision system that enables multi-ship landing, takeoff, and enroute flight in Degraded Visual Environments (DVE). HALS has been successfully flight tested in a variety of scenarios, from brown-out DVE landings, to enroute flight over mountainous terrain, to wire/cable detection during low-level flight. The Radar Enhanced Vision Systems (REVS) is a fixed-wing Enhanced Flight Vision System (EFVS) undergoing prototype development testing. Both systems are based on a fast-scanning, threedimensional 94 GHz radar that produces real-time terrain and obstacle imagery. The radar imagery is fused with synthetic imagery of the surrounding terrain to form a long-range, wide field-of-view display. A symbology overlay is added to provide aircraft state information and, for HALS, approach and landing command guidance cuing. The combination of see-through imagery and symbology provides the key information a pilot needs to perform safe flight operations in DVE conditions. This paper discusses the HALS and REVS systems and technology, presents imagery, and summarizes the recent flight test results.
Lopes, Hélio P; Vieira, Márcia V B; Elias, Carlos N; Gonçalves, Lucio S; Siqueira, José F; Moreira, Edson J L; Vieira, Victor T L; Souza, Letícia C
2013-05-01
This study evaluated the influence of different features of canal curvature geometry on the number of cycles to fracture of a rotary nickel-titanium endodontic instrument subjected to a cyclic fatigue test. BioRaCe BR4C instruments (FKG Dentaire, La Chaux-de Fonds, Switzerland) were tested in 4 grooves simulating curved metallic artificial canals, each one measuring 1.5 mm in width, 20 mm in total length, and 3.5 mm in depth with a U-shaped bottom. The parameters of curvature including the radius and arc lengths and the position of the arc differed in the 4 canal designs. Fractured surfaces and helical shafts of the separated instruments were analyzed by scanning electron microscopy. The Student's t test showed that a significantly lower number of cycles to fracture values were observed for instruments tested in canals with the smallest radius, the longest arc, and the arc located in the middle portion of the canal. Scanning electron microscopic analysis of the fracture surfaces revealed morphologic characteristics of ductile fracture. Plastic deformation was not observed in the helical shaft of the fractured instruments. Curvature geometry including the radius and arc lengths and the position of the arc along the root canal influence the number of cycles to fracture of rotary nickel-titanium instruments subjected to flexural load. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Malcolm, G. N.; Schiff, L. B.
1985-01-01
Two rotary balance apparatuses were developed for testing airplane models in a coning motion. A large scale apparatus, developed for use in the 12-Foot Pressure Wind tunnel primarily to permit testing at high Reynolds numbers, was recently used to investigate the aerodynamics of 0.05-scale model of the F-15 fighter aircraft. Effects of Reynolds number, spin rate parameter, model attitude, presence of a nose boom, and model/sting mounting angle were investigated. A smaller apparatus, which investigates the aerodynamics of bodies of revolution in a coning motion, was used in the 6-by-6 foot Supersonic Wind Tunnel to investigate the aerodynamic behavior of a simple representation of a modern fighter, the Standard Dynamic Model (SDM). Effects of spin rate parameter and model attitude were investigated. A description of the two rigs and a discussion of some of the results obtained in the respective test are presented.
Man-Made Rotary Nanomotors: A Review of Recent Development
Kim, Kwanoh; Guo, Jianhe; Liang, Z. X.; Zhu, F. Q.; Fan, D. L.
2016-01-01
The development rotary nanomotors is an essential step towards intelligent nanomachines and nanorobots. In this article, we review the concept, design, working mechanisms, and applications of the state-of-the-art rotary nanomotors made from synthetic nanoentities. The rotary nanomotors are categorized according to the energy sources employed to drive the rotary motion, including biochemical, optical, magnetic, and electric fields. The unique advantages and limitations for each type of rotary nanomachines are discussed. The advances of rotary nanomotors is pivotal for realizing dream nanomachines for myriad applications including microfluidics, biodiagnosis, nano-surgery, and biosubstance delivery. PMID:27152885
Man-made rotary nanomotors: a review of recent developments
NASA Astrophysics Data System (ADS)
Kim, Kwanoh; Guo, Jianhe; Liang, Z. X.; Zhu, F. Q.; Fan, D. L.
2016-05-01
The development of rotary nanomotors is an essential step towards intelligent nanomachines and nanorobots. In this article, we review the concept, design, working mechanisms, and applications of state-of-the-art rotary nanomotors made from synthetic nanoentities. The rotary nanomotors are categorized according to the energy sources employed to drive the rotary motion, including biochemical, optical, magnetic, and electric fields. The unique advantages and limitations for each type of rotary nanomachines are discussed. The advances of rotary nanomotors is pivotal for realizing dream nanomachines for myriad applications including microfluidics, biodiagnosis, nano-surgery, and biosubstance delivery.
System and method for calibrating a rotary absolute position sensor
NASA Technical Reports Server (NTRS)
Davis, Donald R. (Inventor); Permenter, Frank Noble (Inventor); Radford, Nicolaus A (Inventor)
2012-01-01
A system includes a rotary device, a rotary absolute position (RAP) sensor generating encoded pairs of voltage signals describing positional data of the rotary device, a host machine, and an algorithm. The algorithm calculates calibration parameters usable to determine an absolute position of the rotary device using the encoded pairs, and is adapted for linearly-mapping an ellipse defined by the encoded pairs to thereby calculate the calibration parameters. A method of calibrating the RAP sensor includes measuring the rotary position as encoded pairs of voltage signals, linearly-mapping an ellipse defined by the encoded pairs to thereby calculate the calibration parameters, and calculating an absolute position of the rotary device using the calibration parameters. The calibration parameters include a positive definite matrix (A) and a center point (q) of the ellipse. The voltage signals may include an encoded sine and cosine of a rotary angle of the rotary device.
Mousavi, Sayed Ali; Kargar-Dehnavi, Vida; Mousavi, Sayed Amir
2012-01-01
Background: Nickel-titanium (Ni-Ti) rotary instrument files are important devices in Endodontics in root canal preparation. Ni-Ti file breakage is a critical and problematic issue and irrigation techniques were applied to decrease risk of file failure root. The aim of the present study was to compare the temperature gradient change of different irrigation solutions with Ni-Ti rotary instrument system during root canal preparation and also to define their effects on the file failure. Materials and Methods: A novel computerized instrumentation was utilized and thirty standard (ProFile #25/.04) files were divided into three groups and subjected to a filing in the root canal test. Changes in temperature on teeth under constant instrumental conditions with custom-designed computerized experimental apparatus were measured by using a temperature sensor bonded to the apical hole. A rotary instrument for canal preparation in three series of solution was used and the changes in temperature after each solution were compared. Finally, the file failure results were mentored according to each step of test. Comparisons were performed between group status clinically by using ANOVA (t) test, once the sample showed up normal and differences of P<0.01 were considered significant. All data collected were computerized and analyzed for frequency, distribution, and statistical description. Results: There was a decrease in the temperature of the instruments, which were immersed in 5% NaOCl, when compared with the water group (P<0.01). There was also a decrease in the temperature of the instruments immersed in water, when compared with the no solution group (P<0.01). Test results showed that sodium hypochlorite, water, or air of root canals does alter the properties of gradual temperature change and contributes to the failure of the instruments. Conclusion: By immersing the file in 5% NaOCl, the temperature gradient decreased and instrument failure was reduced. PMID:23087732
Motorcycle emission control demonstration. Final report April--November 1977
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ullman, T.L.; Hare, C.T.
1977-12-01
The testing of ten motorcycles for exhaust emissions of hydrocarbons (HC), carbon monoxide (CO), and oxides of nitrogen (NOx) is described. Emission rates in grams per kilometer are presented for the 1975 Federal Test Procedure and the Highway Fuel Economy Test, as well as in percent or parts per million for several steady-state conditions. The test motorcycles were equipped with 2-stroke, 4-stroke, and rotary engines ranging from about 100 to 1000 cc displacement. Several exhaust emission control techniques were applied, including minor and major carburetor enleanment with and without capacitive discharge ignition, secondary air injection with both pumps and reedmore » valves, port liners, thermal reactors, oxidation catalysts, rotary valve modification, a spark ignited afterburner, and a short-circuited air-fuel mixture extraction system. Driveability, performance, and maladjustment (stock only) testing were also performed. All testing was performed with low accumulated distance on the motorcycles. (Portions of this document are not fully legible)« less
Variation in the modal parameters of space structures
NASA Technical Reports Server (NTRS)
Crawley, Edward F.; Barlow, Mark S.; Van Schoor, Marthinus C.; Bicos, Andrew S.
1992-01-01
An analytic and experimental study of gravity and suspension influences on space structural test articles is presented. A modular test article including deployable, erectable, and rotary modules was assembled in three one- and two-dimensional structures. The two deployable modules utilized cable diagonal bracing rather than rigid cross members; within a bay of one of the deployable modules, the cable preload was adjustable. A friction lock was used on the alpha joint to either allow or prohibit rotary motion. Suspension systems with plunge fundamentals of 1, 2, and 5 Hz were used for ground testing to evaluate the influences of suspension stiffness. Assembly and reassembly testing was performed, as was testing on two separate shipsets at two test sites. Trends and statistical variances in modal parameters are presented as a function of force amplitude, joint preload, reassembly, shipset and suspension. Linear finite element modeling of each structure provided analytical results for 0-g unsuspended and 1-g suspended models, which are correlated with the analytical model.
Single ball bearing lubricant and material evaluator
NASA Technical Reports Server (NTRS)
Hall, Philip B. (Inventor); Novak, Howard L. (Inventor)
2005-01-01
A test apparatus provides an applied load to a monoball through a trolley which moves along a loading axis. While applying the load to the monoball, the torque meter is in communication with the spherical monoball, and a load cell senses the application of applied force to the monoball. Meanwhile, a rotary actuary imports rotary oscillating motion to the monoball which is sensed by a position sensor and a torque meter. Accordingly, a processor can determine the coefficient of friction in substantially real time along with a cycles per second rate.
Single Ball Bearing Lubricant and Material Evaluator
NASA Technical Reports Server (NTRS)
Hall, Philip B. (Inventor); Novak, Howard L. (Inventor)
2005-01-01
A test apparatus provides an applied load to a monoball through a trolley which moves along a loading axis. While applying the load to the monoball, the torque meter is in communication with the spherical monoball, and a load cell senses the application of applied force to the monoball. Meanwhile, a rotary actuary imports rotary oscillating motion to the monoball which is sensed by a position sensor and a torque meter. Accordingly, a processor can determine the coefficient of friction in substantially real time along with a cycles per second rate.
Ghivari, Sheetal B; Kubasad, Girish C; Deshpande, Preethi
2012-01-01
Aim: To evaluate the bacteria extruded apically during root canal preparation using two hand and rotary instrumentation techniques. Materials and Methods: Eighty freshly extracted mandibular premolars were mounted in bacteria collection apparatus. Root canals were contaminated with the pure culture of Enterococcus fecalis (ATCC 29212) and dried at 37°C for 24 h. Bacteria extruded were collected, incubated in brain heart infusion agar for 24 h at 36°C and the colony forming units (CFU) were counted. Statistical Analysis: The mean number of colony forming units were calculated by One-way ANOVA and comparison between the groups made by multiple comparison (Dunnet D) test. Results: The step-back technique extruded highest number of bacteria in comparison to other hand and rotary Ni–Ti systems. Conclusion: Under the limitation of this study all hand and rotary instrumentation techniques extruded bacteria. Among all the instrumentation techniques step-back technique extruded more number of bacteria and K-3 system the least. Further in vivo research in this direction could provide more insight into the biologic factors associated and focus on bacterial species that essentially play a major role in post instrumentation flare-ups. PMID:22368332
Influence of the helicopter environment on patient care capabilities: Flight crew perceptions
NASA Technical Reports Server (NTRS)
Meyers, K. Jeffrey; Rodenberg, Howard; Woodard, Daniel
1994-01-01
Flight crew perceptions of the effect of the rotary wing environment on patient care capabilities have not been subject to statistical analysis. We hypothesized that flight crew perceived significant difficulties in performing patient care tasks during air medical transport. A survey instrument was distributed to a convenience sample of flight crew members from twenty flight programs. Respondents were asked to compare the difficulty of performing patient care tasks in rotary wing and standard (emergency department or intensive care unit) settings. Demographic data collected on respondents included years of flight experience, flights per month, crew duty position, and primary aircraft in which the respondent worked. Statistical analysis was performed as appropriate using Student's t-test, type 111 sum of squares, and analysis of variance. Alpha was defined as p is less than or equal to .05. Fifty-five percent of programs (90 individuals) responded. All tasks were rated significantly more difficult in the rotary wing environment. Ratings were not significantly correlated with flight experience, duty position, flights per month, or aircraft used. We conclude that the performance of patient care tasks are perceived by air medical flight crew to be significantly more difficult during rotary wing air medical transport than in hospital settings.
Apical extrusion of debris in four different endodontic instrumentation systems: A meta-analysis.
Western, J Sylvia; Dicksit, Daniel Devaprakash
2017-01-01
All endodontic instrumentation systems tested so far, promote apical extrusion of debris, which is one of the main causes of postoperative pain, flare ups, and delayed healing. Of this meta-analysis was to collect and analyze in vitro studies quantifying apically extruded debris while using Hand ProTaper (manual), ProTaper Universal (rotary), Wave One (reciprocating), and self-adjusting file (SAF; vibratory) endodontic instrumentation systems and to determine methods which produced lesser extrusion of debris apically. An extensive electronic database search was done in PubMed, Scopus, Cochrane, LILACS, and Google Scholar from inception until February 2016 using the key terms "Apical Debris Extrusion, extruded material, and manual/rotary/reciprocating/SAF systems." A systematic search strategy was followed to extract 12 potential articles from a total of 1352 articles. The overall effect size was calculated from the raw mean difference of weight of apically extruded debris. Statistically significant difference was seen in the following comparisons: SAF < Wave One, SAF < Rotary ProTaper. Apical extrusion of debris was invariably present in all the instrumentation systems analyzed. SAF system seemed to be periapical tissue friendly as it caused reduced apical extrusion compared to Rotary ProTaper and Wave One.
Influence of the helicopter environment on patient care capabilities: flight crew perceptions
NASA Technical Reports Server (NTRS)
Myers, K. J.; Rodenberg, H.; Woodard, D.
1995-01-01
INTRODUCTION: Flight crew perceptions of the effect of the rotary-wing environment on patient-care capabilities have not been subject to statistical analysis. We hypothesized that flight crew members perceived significant difficulties in performing patient-care tasks during air medical transport. METHODS: A survey was distributed to a convenience sample of flight crew members from 20 flight programs. Respondents were asked to compare the difficulty of performing patient-care tasks in rotary-wing and standard (emergency department or intensive care unit) settings. Demographic data collected on respondents included years of flight experience, flights per month, crew duty position and primary aircraft in which the respondent worked. Statistical analysis was performed as appropriate using Student's t-test, type III sum of squares, and analysis of variance. Alpha was defined as p < 0.05. RESULTS: Fifty-five percent of programs (90 individuals) responded. All tasks were significantly rated more difficult in the rotary-wing environment. Ratings were not significantly correlated with flight experience, duty position, flights per month or aircraft used. CONCLUSIONS: We conclude that the performance of patient-care tasks are perceived by air medical flight crew to be significantly more difficult during rotary-wing air medical transport than in hospital settings.
Apical extrusion of debris using two hand and two rotary instrumentation techniques.
Reddy, S A; Hicks, M L
1998-03-01
The purpose of this study was to investigate the quantity of apical debris produced in vitro using two hand and two rotary instrumentation techniques. Sixty minimally curved, mature human mandibular premolars with single canals were divided into 4 groups of 15 teeth each and prepared using step-back instrumentation with K-files, balanced force with Flex-R files, Lightspeed nickel-titanium instruments, or .04 taper ProFile Series 29 rotary nickel-titanium files. Debris extruded through the apical foramen during instrumentation was collected on preweighed filters. The mean weight of extruded debris for each group was statistically analyzed using a Kruskal Wallis one-way analysis of variance and a Mann-Whitney U rank sum tested. Although all instrumentation techniques produced apically extruded debris, step-back instrumentation produced significantly more debris than the other methods (p < 0.0001). There was no difference between balanced force hand instrumentation and the two rotary nickel-titanium instrumentation methods (p > 0.05). Hand or engine-driven instrumentation that uses rotation seems to reduce significantly the amount of debris extruded apically when compared with a push-pull (filing) technique. Decreased apical extrusion of debris has strong implications for a decreased incidence of postoperative inflammation and pain.
Analysis of rotary balance data for the F-15 airplane including the effect of conformal fuel tanks
NASA Technical Reports Server (NTRS)
Barnhart, B.
1982-01-01
F-15 rotary balance data was analyzed, and the influence of control deflections, Reynolds number and airplane components, i.e., body, wing, horizontal and vertical tails, as well as conformal tanks, on the aerodynamics up to 90 degrees angle of attack are discussed. Steady state spin mode predictions using these data are presented, which show excellent correlation with spin tunnel and flight test results. Generally, the data shows damped yawing moment slopes with rotation at all angles of attack, and good control effectiveness. Differences in the rotary aerodynamics due to the addition of conformal tanks are minimal. The small differences in the region of the flat spin do, however, indicate that the resulting spin mode would be slightly flatter and faster for a conformal tank equipped airplane. The addition of conformal tanks make the airplane more departure susceptible.
A Four-Feet Walking-Type Rotary Piezoelectric Actuator with Minute Step Motion.
Liu, Yingxiang; Wang, Yun; Liu, Junkao; Xu, Dongmei; Li, Kai; Shan, Xiaobiao; Deng, Jie
2018-05-08
A four-feet walking-type rotary piezoelectric actuator with minute step motion was proposed. The proposed actuator used the rectangular motions of four driving feet to push the rotor step-by-step; this operating principle was different with the previous non-resonant actuators using direct-driving, inertial-driving, and inchworm-type mechanisms. The mechanism of the proposed actuator was discussed in detail. Transient analyses were accomplished by ANSYS software to simulate the motion trajectory of the driving foot and to find the response characteristics. A prototype was manufactured to verify the mechanism and to test the mechanical characteristics. A minimum resolution of 0.095 μrad and a maximum torque of 49 N·mm were achieved by the prototype, and the output speed was varied by changing the driving voltage and working frequency. This work provides a new mechanism for the design of a rotary piezoelectric actuator with minute step motion.
A Four-Feet Walking-Type Rotary Piezoelectric Actuator with Minute Step Motion
Wang, Yun; Liu, Junkao; Xu, Dongmei; Li, Kai; Shan, Xiaobiao; Deng, Jie
2018-01-01
A four-feet walking-type rotary piezoelectric actuator with minute step motion was proposed. The proposed actuator used the rectangular motions of four driving feet to push the rotor step-by-step; this operating principle was different with the previous non-resonant actuators using direct-driving, inertial-driving, and inchworm-type mechanisms. The mechanism of the proposed actuator was discussed in detail. Transient analyses were accomplished by ANSYS software to simulate the motion trajectory of the driving foot and to find the response characteristics. A prototype was manufactured to verify the mechanism and to test the mechanical characteristics. A minimum resolution of 0.095 μrad and a maximum torque of 49 N·mm were achieved by the prototype, and the output speed was varied by changing the driving voltage and working frequency. This work provides a new mechanism for the design of a rotary piezoelectric actuator with minute step motion. PMID:29738495
Aminsobhani, Mohsen; Razmi, Hasan; Nozari, Solmaz
2015-07-01
Cleaning and shaping of the root canal system is an important step in endodontic therapy. New instruments incorporate new preparation techniques that can improve the efficacy of cleaning and shaping. The aim of this study was to compare the efficacy of Mtwo and RaCe rotary file systems in straightening the canal curvature using only one file or the conventional method. Sixty mesial roots of extracted human mandibular molars were prepared by RaCe and Mtwo nickel-titanium (NiTi) rotary files using the conventional and only one rotary file methods. The working length was 18 mm and the curvatures of the root canals were between 15-45°. By superimposing x-ray images before and after the instrumentation, deviation of the canals was assessed using Adobe Photoshop CS3 software. Preparation time was recorded. Data were analyzed using three-way ANOVA and Tukey's post hoc test. There were no significant differences between RaCe and Mtwo or between the two root canal preparation methods in root canal deviation in buccolingual and mesiodistal radiographs (P>0.05). Changes of root canal curvature in >35° subgroups were significantly more than in other subgroups with smaller canal curvatures. Preparation time was shorter in one file only technique. According to the results, the two rotary systems and the two root canal preparation methods had equal efficacy in straightening the canals; but the preparation time was shorter in one file only group.
AERODYNAMIC CHARACTERISTICS OF TWO ROTARY WING UAV DESIGNS
NASA Technical Reports Server (NTRS)
Jones, Henry E.; Wong, Oliver D.; Noonan, Kevin W.; Reis, Deane G.; Malovrh, Brendon D.
2006-01-01
This paper presents the results of an experimental investigation of two rotary-wing UAV designs. The primary goal of the investigation was to provide a set of interactional aerodynamic data for an emerging class of rotorcraft. The present paper provides an overview of the test and an introduction to the test articles, and instrumentation. Sample data in the form of a parametric study of fixed system lift and drag coefficient response to changes in configuration and flight condition for both rotor off and on conditions are presented. The presence of the rotor is seen to greatly affect both the character and magnitude of the response. The affect of scaled stores on body drag is observed to be dependent on body shape.
Aerodynamic Characteristics of Two Rotary Wing UAV Designs
NASA Technical Reports Server (NTRS)
Jones, Henry E.; Wong, Oliver D.; Noonan, Kevin W.; Reis, Deane G.; Malovrh, Brendon D.
2006-01-01
This paper presents the results of an experimental investigation of two rotary-wing UAV designs. The primary goal of the investigation was to provide a set of interactional aerodynamic data for an emerging class of rotorcraft. The present paper provides an overview of the test and an introduction to the test articles, and instrumentation. Sample data in the form of a parametric study of fixed system lift and drag coefficient response to changes in configuration and flight condition for both rotor off and on conditions are presented. The presence of the rotor is seen to greatly affect both the character and magnitude of the response. The affect of scaled stores on body drag is observed to be dependent on body shape.
NASA Technical Reports Server (NTRS)
Ralston, J.
1983-01-01
The influence of airplane components, as well as wing location and tail length, on the rotational flow aerodynamics is discussed for a 1/6 scale general aviation airplane model. The airplane was tested in a built-up fashion (i.e., body, body-wing, body-wing-vertical, etc.) in the presence of two wing locations and two body lengths. Data were measured, using a rotary balance, over an angle-of-attack range of 8 deg to 90 deg, and for clockwise and counter-clockwise rotations covering an omega b/2V range of 0 to 0.9.
Effect of Laminating Pressure on Polymeric Multilayer Nanofibrous Membranes for Liquid Filtration.
Yalcinkaya, Fatma; Hruza, Jakub
2018-04-24
In the new century, electrospun nanofibrous webs are widely employed in various applications due to their specific surface area and porous structure with narrow pore size. The mechanical properties have a major influence on the applications of nanofiber webs. Lamination technology is an important method for improving the mechanical strength of nanofiber webs. In this study, the influence of laminating pressure on the properties of polyacrylonitrile (PAN) and polyvinylidene fluoride (PVDF) nanofibers/laminate was investigated. Heat-press lamination was carried out at three different pressures, and the surface morphologies of the multilayer nanofibrous membranes were observed under an optical microscope. In addition, air permeability, water filtration, and contact angle experiments were performed to examine the effect of laminating pressure on the breathability, water permeability and surface wettability of multilayer nanofibrous membranes. A bursting strength test was developed and applied to measure the maximum bursting pressure of the nanofibers from the laminated surface. A water filtration test was performed using a cross-flow unit. Based on the results of the tests, the optimum laminating pressure was determined for both PAN and PVDF multilayer nanofibrous membranes to prepare suitable microfilters for liquid filtration.
Rock Drilling Performance Evaluation by an Energy Dissipation Based Rock Brittleness Index
NASA Astrophysics Data System (ADS)
Munoz, H.; Taheri, A.; Chanda, E. K.
2016-08-01
To reliably estimate drilling performance both tool-rock interaction laws along with a proper rock brittleness index are required to be implemented. In this study, the performance of a single polycrystalline diamond compact (PDC) cutter cutting and different drilling methods including PDC rotary drilling, roller-cone rotary drilling and percussive drilling were investigated. To investigate drilling performance by rock strength properties, laboratory PDC cutting tests were performed on different rocks to obtain cutting parameters. In addition, results of laboratory and field drilling on different rocks found elsewhere in literature were used. Laboratory and field cutting and drilling test results were coupled with values of a new rock brittleness index proposed herein and developed based on energy dissipation withdrawn from the complete stress-strain curve in uniaxial compression. To quantify cutting and drilling performance, the intrinsic specific energy in rotary-cutting action, i.e. the energy consumed in pure cutting action, and drilling penetration rate values in percussive action were used. The results show that the new energy-based brittleness index successfully describes the performance of different cutting and drilling methods and therefore is relevant to assess drilling performance for engineering applications.
Comparison of the effect of three autogenous bone harvesting methods on cell viability in rabbits
Moradi Haghgoo, Janet; Arabi, Seyed Reza; Hosseinipanah, Seyyed Mohammad; Solgi, Ghasem; Rastegarfard, Neda; Farhadian, Maryam
2017-01-01
Background. This study was designed to compare the viability of autogenous bone grafts, harvested using different methods, in order to determine the best harvesting technique with respect to more viable cells. Methods. In this animal experimental study, three harvesting methods, including manual instrument (chisel), rotary device and piezosurgery, were used for harvesting bone grafts from the lateral body of the mandible on the left and right sides of 10 rabbits. In each group, 20 bone samples were collected and their viability was assessed using MTS kit. Statistical analyses, including ANOVA and post hoc Tukey tests, were used for evaluating significant differences between the groups. Results. One-way ANOVA showed significant differences between all the groups (P=0.000). Data analysis using post hoc Tukey tests indicated that manual instrument and piezosurgery had no significant differences with regard to cell viability (P=0.749) and the cell viability in both groups was higher than that with the use of a rotary instrument (P=0.000). Conclusion. Autogenous bone grafts harvested with a manual instrument and piezosurgery had more viable cells in comparison to the bone chips harvested with a rotary device. PMID:28748046
Kiran, S; Prakash, Sandeep; Siddharth, Pujari R; Saha, Supradip; Geojan, Naiza E; Ramachandran, Mookambika
2016-07-01
The effect of smear layer and debris on the success rate of endodontic treatment has not yet been definitely determined. So the present study was aimed to evaluate the amount of smear layer and debris on the canal walls prepared with a combination of hand and rotary ProTaper technique using NaOCl and ethylenediaminetetraacetic acid (EDTA) alternately as root canal irrigants using scanning electron microscope (SEM). Eighty intact freshly extracted human permanent mandibular premolar teeth were collected and randomly divided equally into four groups. In group I canals were prepared with hand K-Flexofiles; group II with rotary ProTaper instruments; group III with rotary ProTaper instruments and final instrumentation was done with hand K-Flexofile; group IV with rotary ProTaper instruments and final instrumentation was done with RC-Prep and irrigated with 1 mL of normal saline. In all groups canals were irrigated using NaOCl and EDTA alternately. After instrumentation, the teeth were prepared for SEM examination using five-score indices for debris and smear layer at coronal, middle, and apical third levels. Statistical analysis was performed using chi-square test (p < 0.05) and Kruskal-Wallis test (p < 0.05). Statistically significant difference was observed between the groups in cleaning the apical third. Groups I and III showed better canal cleanliness compared to group II. The use of EDTA and NaOCl in group III was more effective in removing debris and smear layer compared to EDTA and normal saline in group IV. Regardless of the instrumentation technique employed and the irrigant used, the cleaning ability decreased in the apical third, resulting in higher debris and smear layer scores compared to coronal and middle third levels. None of the instrumentation techniques in the present study could completely eliminate the smear layer and debris from the canal walls. Instrumentation of the canals with hand files after automated rotary preparation could result in cleaner canal walls. Alternate irrigation with NaOCl and EDTA is effective in the removal of debris and smear layer in the coronal and middle level, but the effectiveness in the apical third is less.
40 CFR 63.1384 - Performance test requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... performance test, the owner or operator must monitor and record the glass pull rate for each glass-melting furnace and, if different, the glass pull rate for each rotary spin manufacturing line and flame attenuation manufacturing line. Record the glass pull rate every 15 minutes during any performance test...
Govindaraju, Lavanya; Subramanian, EMG
2017-01-01
Introduction Pulp therapy in primary teeth has been performed using various instrumentation techniques. However, the conventional instrumentation technique used for root canal preparation in primary teeth is hand instrumentation. Various Nickel-Titanium (Ni-Ti) instruments are available to perform efficient root canal preparation in primary teeth. These Ni-Ti instruments has been designed to aid in better root canal preparation in permanent teeth but are rarely used in primary teeth. It is necessary to assess the feasibility of using these adult rotary files with a modified sequence in primary teeth. Aim To compare the quality of obturation and instrumentation time during root canal preparation using hand files and modified rotary file systems in primary molars. Materials and Methods Forty-five primary mandibular molars were randomly assigned to three experimental groups (n=15). Group I was instrumented using k-hand files, Group II with S2 ProTaper universal file and Group III with 0.25 tip 4% taper K3 rotary file. Standardized digital radiographs were taken before and after root canal instrumentation. Root canal preparation time was also recorded. Statistical analysis of the obtained data was done using SPSS Software version 17.0. An intergroup comparison of the instrumentation time and the quality of obturation was done using ANOVA and Chi-square test with the level of significance set at 0.05. Results No significant differences were noted with regard to the quality of obturation (p=0.791). However, a statistically significant difference was noted in the instrumentation time between the three groups (p<0.05). ProTaper rotary system had significantly lesser instrumentation time when compared to that of K3 rotary system and hand file system. Conclusion The hand files, S2 ProTaper Universal and K3 0.25 tip 4% taper files systems performed similarly with respect to the quality of obturation. There was a significant difference in instrumentation time with manual instrumentation compared to the modified rotary file systems in primary teeth. PMID:29207834
Dual motion valve with single motion input
NASA Technical Reports Server (NTRS)
Belew, Robert (Inventor)
1987-01-01
A dual motion valve includes two dual motion valve assemblies with a rotary input which allows the benefits of applying both rotary and axial motion to a rotary sealing element with a plurality of ports. The motion of the rotary sealing element during actuation provides axial engagement of the rotary sealing element with a stationary valve plate which also has ports. Fluid passages are created through the valve when the ports of the rotary sealing element are aligned with the ports of the stationary valve plate. Alignment is achieved through rotation of the rotary sealing element with respect to the stationary valve plate. The fluid passages provide direct paths which minimize fluid turbulence created in the fluid as it passes through the valve.
Dagna, Alberto; El Abed, Rashid; Hussain, Sameeha; Abu-Tahun, Ibrahim H; Visai, Livia; Bertoglio, Federico; Bosco, Floriana; Beltrami, Riccardo; Poggio, Claudio; Kim, Hyeon-Cheol
2017-11-01
This study compared the amount of apically extruded bacteria during the glide-path preparation by using multi-file and single-file glide-path establishing nickel-titanium (NiTi) rotary systems. Sixty mandibular first molar teeth were used to prepare the test apparatus. They were decoronated, blocked into glass vials, sterilized in ethylene oxide gas, infected with a pure culture of Enterococcus faecalis, randomly assigned to 5 experimental groups, and then prepared using manual stainless-steel files (group KF) and glide-path establishing NiTi rotary files (group PF with PathFiles, group GF with G-Files, group PG with ProGlider, and group OG with One G). At the end of canal preparation, 0.01 mL NaCl solution was taken from the experimental vials. The suspension was plated on brain heart infusion agar and colonies of bacteria were counted, and the results were given as number of colony-forming units (CFU). The manual instrumentation technique tested in group KF extruded the highest number of bacteria compared to the other 4 groups ( p < 0.05). The 4 groups using rotary glide-path establishing instruments extruded similar amounts of bacteria. All glide-path establishment instrument systems tested caused a measurable apical extrusion of bacteria. The manual glide-path preparation showed the highest number of bacteria extruded compared to the other NiTi glide-path establishing instruments.
PILOT-SCALE INCINERATION TEST BURN OF TCDD-CONTAMINATED TRICHLOROPHENOL PRODUCTION WASTE
A series of three tests directed at evaluating the incinerability of the toluene stillbottoms waste from trichlorophenol production previously generated by the Vertac Chemical Company were performed in the Combustion Research Facility (CRF) rotary kiln incineration system. This w...
Priya, N Tulasi; Chandrasekhar, Veeramachaneni; Anita, S; Tummala, Muralidhar; Raj, T B Phanindhar; Badami, Vijetha; Kumar, Pradeep; Soujanya, E
2014-12-01
The purpose of this study was to compare the incidence of dentinal micro cracks after instrumentation with various types of NiTi files in rotary and reciprocating motion. One hundred human extracted mandibular central incisors were taken and divided into 10 groups (n=10 teeth per group). Group 1- No preparation, Group 2 - Hand instrumentation, Groups 3,4 - ProTaper files in rotary and reciprocating motion, Groups 5,6 - ProTaper Next files in rotary and reciprocating motion, Groups 7,8 - Oneshape files in rotary and reciprocating motion, Groups 9,10 - Reciproc files in rotary and reciprocating motion. Specimens were sectioned horizontally at 3,6 and 9 mm from the apex and dentinal micro cracks were observed under a stereomicroscope. There was a statistically significant difference between the groups (p<0.05). There were no significant differences in crack formation between the groups (Protaper Next - Rot, Protaper Next - Rec, Reciproc - Rec); (ProTaper - Rot, ProTaper - Rec, Oneshape - Rot), (Oneshape - Rot, Reciproc - Rot), (One shape Reciproc, Reciproc - Rec); (p >.05). Least cracks were seen in canals instrumented with Pro Taper Next files both in rotary and reciprocating motion. Full sequence rotary systems showed less cracks than single file systems and full sequence rotary systems showed less cracks in reciprocating motion than in rotary motion.
The IRAC Shutter Mechanism: Residual Magnetism and the Rotary Solenoid
NASA Technical Reports Server (NTRS)
Schwinger, Scott; Hakun, Claef; Brown, Gary; Blumenstock, Ken
2002-01-01
The Infrared Array Camera (IRAC) Shutter mechanism was originally presented in the paper, 'A Low Power Cryogenic Shutter Mechanism for Use on Infrared Imagers' at the 34th Aerospace Mechanisms Symposium, May 2000. At that time, the shutter was believed to be performing flawlessly and there was every indication it would continue to do so. In early spring of 2001, the calibration shutter, a rotary solenoid designed to be fail-safe open, remained in a closed state with no power to the electromagnetic coils. The ensuing investigation, subsequent testing, proposed remedy, and lessons learned are the focus of this paper.
NASA Technical Reports Server (NTRS)
Mulcay, W. J.; Chu, J.
1980-01-01
Aerodynamic characteristics obtained in a helical flow environment utilizing a rotary balance located in the Langley spin tunnel are presented in plotted form for a 1/10 scale single engine agricultural airplane model. The configurations tested include the basic airplane, various wing leading edge and wing tip devices, elevator, aileron, and rudder control settings, and other modifications. Data are presented without analysis for an angle of attack range of 8 deg to 90 deg, and clockwise and counter-clockwise rotations covering a spin coefficient range from 0 to .9.
NASA Technical Reports Server (NTRS)
Pantason, P.; Dickens, W.
1979-01-01
Aerodynamic characteristics obtained in a rotational flow environment utilizing a rotary balance located in the Langley spin tunnel are presented in plotted form for a 1/6 scale, single engine trainer airplane model. The configurations tested included the basic airplane, various wing leading edge devices, elevator, aileron and rudder control settings as well as airplane components. Data are presented without analysis for an angle of attack range of 8 to 90 degrees and clockwise and counter-clockwise rotations.
Design of a high-performance rotary stratified-charge research aircraft engine
NASA Technical Reports Server (NTRS)
Jones, C.; Mount, R. E.
1984-01-01
The power section for an advanced rotary stratified-charge general aviation engine has been designed under contract to NASA. The single-rotor research engine of 40 cubic-inches displacement (RCI-40), now being procured for test initiation this summer, is targeted for 320 T.O. horse-power in a two-rotor production engine. The research engine is designed for operating on jet-fuel, gasoline or diesel fuel and will be used to explore applicable advanced technologies and to optimize high output performance variables. Design of major components of the engine is described in this paper.
NASA Technical Reports Server (NTRS)
Mulcay, W.; Rose, R.
1979-01-01
Aerodynamic characteristics obtained in a rotational flow environment utilizing a rotary balance located in the Langley spin tunnel are presented in plotted form for a 1/5-scale, single-engine, high-wing, general aviation airplane model. The configurations tested included various tail designs and fuselage shapes. Data are presented without analysis for an angle of attack range of 8 to 90 degrees and clockwise and counter-clockwise rotations covering an Omega b/2 v range from 0 to 0.85.
1989-09-01
STEEL STL STEEL TFL TEFLON TIL TILE WD WOOD WRI WROUGHT IRON Z OTHER A-14 coam Bc~ai=L a TEST PIT ois rn iEI AR AIR - ROTARY 8 BORED OR AUGERED C CABLE-TOOL...CO CORING Cs CHILLED SHOT D DUG DH DOWN THE HOLE HAMMER HA HAND AUGERED HS HOLLOW STEM AUGER J JETTED MR DIRECT CIRCULATION ROTARY , MUD p AIR ...INSTITUTE WARI WATER AND AIR RESEARCH. INC. WIL WILSON AND CO. A-18 M 0E 7 PIT E V/n.. CK: N’Y ESCI ENGINEERING -SCIENCE NA NOT APPLICABLE RB MR
Luebke, N H; Brantley, W A; Sabri, Z I; Luebke, F L; Lausten, L L
1995-05-01
A laboratory study was performed on machine-driven Canal Master drills to determine their physical dimensions, torsional performance, bending properties, and metallurgical characteristics in fracture. Physical dimensions were determined for each of the available sizes (#50 to #100) of Canal Master drills from the manufacturer that distributes these instruments in the United States. Samples were also tested in clockwise torsion using a Maillefer memocouple. Bending properties of cantilever specimens were measured with a Tinius Olsen stiffness tester. Bending fatigue testing was performed on a unique laboratory apparatus. Scanning electron microscope examination confirmed visual observations that the stainless steel Canal Master drills exhibited ductile torsional fracture. This study is part of a continuing investigation to establish standards for all machine-driven rotary endodontic instruments.
Deformation and fracture of Mtwo rotary nickel-titanium instruments after clinical use.
Inan, Ugur; Gonulol, Nihan
2009-10-01
In recent years, a number of rotary nickel titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system. Although the NiTi instruments are more flexible than the stainless steel files, the main problem with the rotary NiTi instruments is the failure of the instruments. The aim of this study was to evaluate the deformation and fracture rate of Mtwo rotary nickel-titanium instruments (VDW, Munich, Germany) discarded after routine clinical use. A total of 593 Mtwo rotary NiTi instruments were collected after clinical use from the clinic of endodontics over 12 months. The length of the files was measured using a digital caliper to determine any fracture, and then all the files were evaluated under a stereomicroscope for defects such as unwinding, curving, or bending and fracture. The fracture faces of separated files were also evaluated under a scanning electron microscope. The data were analyzed using a chi-square and z test. A percentage of all files (25.80%) showed defects, and the major defect was fracture (16.02%). The most frequently fractured file was #10.04 (30.39%). Deformations without fracture were mostly observed on #15.05 files (25.47%). A higher rate of deformation was observed for #10.04 and #15.05 files. Therefore, these files should be considered as single-use instruments. Because cyclic fatigue was the cause of 71.58% of the instrument fractures, it is also important not to exceed the maximum number of usage recommended by the manufacturer and discard the instruments on a regular basis.
Jain, Niharika; Pawar, Ajinkya M.; Ukey, Piyush D.; Jain, Prashant K.; Thakur, Bhagyashree; Gupta, Abhishek
2017-01-01
Objectives: To compare the relative axis modification and canal concentricity after glide path preparation with 20/0.02 hand K-file (NITIFLEX®) and 20/0.04 rotary file (HyFlex™ CM) with subsequent instrumentation with 1.5 mm self-adjusting file (SAF). Materials and Methods: One hundred and twenty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer, Ballaigues, Switzerland) were acquired and randomly divided into following two groups (n = 60): group 1, establishing glide path till 20/0.02 hand K-file (NITIFLEX®) followed by instrumentation with 1.5 mm SAF; and Group 2, establishing glide path till 20/0.04 rotary file (HyFlex™ CM) followed by instrumentation with 1.5 mm SAF. Pre- and post-instrumentation digital images were processed with MATLAB R 2013 software to identify the central axis, and then superimposed using digital imaging software (Picasa 3.0 software, Google Inc., California, USA) taking five landmarks as reference points. Student's t-test for pairwise comparisons was applied with the level of significance set at 0.05. Results: Training blocks instrumented with 20/0.04 rotary file and SAF were associated less deviation in canal axis (at all the five marked points), representing better canal concentricity compared to those, in which glide path was established by 20/0.02 hand K-files followed by SAF instrumentation. Conclusion: Canal geometry is better maintained after SAF instrumentation with a prior glide path established with 20/0.04 rotary file. PMID:28855752
Chakka, N V Murali Krishna; Ratnakar, P; Das, Sanjib; Bagchi, Anandamy; Sudhir, Sudhir; Anumula, Lavanya
2012-11-01
Visual and microscopic evaluation of defects caused by torsional fatigue in hand and rotary nickel titanium (NiTi) instruments. Ninety-six NiTi greater taper instruments which were routinely used for root canal treatment only in anterior teeth were selected for the study. The files taken include ProTaper for hand use, ProTaper Rotary files and Endowave rotary files. After every use, the files were observed visually and microscopically (Stereomicroscope at 10×) to evaluate the defects caused by torsional fatigue. Scoring was given according to a new classification formulated which gives an indication of the severity of the defect or damage. Data was statistically analyzed using KruskallWallis and Mann-Whitney U test. Number of files showing defects were more under stereomicroscope than visual examination. But, the difference in the evaluation methods was not statistically significant. The different types of defects observed were bent instrument, straightening/stretching of twist contour and partial reverse twisting. Endowave files showed maximum number of defects followed by ProTaper for hand use and least in ProTaper Rotary. Visible defects due to torsional fatigue do occur in NiTi instruments after clinical use. Both visual and microscopic examinations were efficient in detecting defects caused due to torsional fatigue. This study emphasizes that all files should be observed for any visible defects before and after every instrumentation cycle to minimize the risk of instrument separation and failure of endodontic therapy.
Thermal co-treatment of combustible hazardous waste and waste incineration fly ash in a rotary kiln.
Huber, Florian; Blasenbauer, Dominik; Mallow, Ole; Lederer, Jakob; Winter, Franz; Fellner, Johann
2016-12-01
As current disposal practices for municipal solid waste incineration (MSWI) fly ash are either associated with significant costs or negative environmental impacts, an alternative treatment was investigated in a field scale experiment. Thereto, two rotary kilns were fed with hazardous waste, and moistened MSWI fly ash (water content of 23%) was added to the fuel of one kiln with a ratio of 169kg/Mg hazardous waste for 54h and 300kg/Mg hazardous waste for 48h while the other kiln was used as a reference. It was shown that the vast majority (>90%) of the inserted MSWI fly ash was transferred to the bottom ash of the rotary kiln. This bottom ash complied with the legal limits for non-hazardous waste landfills, thereby demonstrating the potential of the investigated method to transfer hazardous waste (MSWI fly ash) into non-hazardous waste (bottom ash). The results of a simple mixing test (MSWI fly ash and rotary kiln bottom ash have been mixed accordingly without thermal treatment) revealed that the observed transformation of hazardous MSWI fly ash into non-hazardous bottom ash during thermal co-treatment cannot be referred to dilution, as the mixture did not comply with legal limits for non-hazardous waste landfills. For the newly generated fly ash of the kiln, an increase in the concentration of Cd, K and Pb by 54%, 57% and 22%, respectively, was observed. In general, the operation of the rotary kiln was not impaired by the MSWI fly ash addition. Copyright © 2016 Elsevier Ltd. All rights reserved.
Aminsobhani, Mohsen; Nozari, Solmaz
2015-01-01
Objectives: Cleaning and shaping of the root canal system is an important step in endodontic therapy. New instruments incorporate new preparation techniques that can improve the efficacy of cleaning and shaping. The aim of this study was to compare the efficacy of Mtwo and RaCe rotary file systems in straightening the canal curvature using only one file or the conventional method. Materials and Methods: Sixty mesial roots of extracted human mandibular molars were prepared by RaCe and Mtwo nickel-titanium (NiTi) rotary files using the conventional and only one rotary file methods. The working length was 18 mm and the curvatures of the root canals were between 15–45°. By superimposing x-ray images before and after the instrumentation, deviation of the canals was assessed using Adobe Photoshop CS3 software. Preparation time was recorded. Data were analyzed using three-way ANOVA and Tukey’s post hoc test. Results: There were no significant differences between RaCe and Mtwo or between the two root canal preparation methods in root canal deviation in buccolingual and mesiodistal radiographs (P>0.05). Changes of root canal curvature in >35° subgroups were significantly more than in other subgroups with smaller canal curvatures. Preparation time was shorter in one file only technique. Conclusion: According to the results, the two rotary systems and the two root canal preparation methods had equal efficacy in straightening the canals; but the preparation time was shorter in one file only group. PMID:26877736
Apical extrusion of debris in four different endodontic instrumentation systems: A meta-analysis
Western, J. Sylvia; Dicksit, Daniel Devaprakash
2017-01-01
Background: All endodontic instrumentation systems tested so far, promote apical extrusion of debris, which is one of the main causes of postoperative pain, flare ups, and delayed healing. Objectives: Of this meta-analysis was to collect and analyze in vitro studies quantifying apically extruded debris while using Hand ProTaper (manual), ProTaper Universal (rotary), Wave One (reciprocating), and self-adjusting file (SAF; vibratory) endodontic instrumentation systems and to determine methods which produced lesser extrusion of debris apically. Methodology: An extensive electronic database search was done in PubMed, Scopus, Cochrane, LILACS, and Google Scholar from inception until February 2016 using the key terms “Apical Debris Extrusion, extruded material, and manual/rotary/reciprocating/SAF systems.” A systematic search strategy was followed to extract 12 potential articles from a total of 1352 articles. The overall effect size was calculated from the raw mean difference of weight of apically extruded debris. Results: Statistically significant difference was seen in the following comparisons: SAF < Wave One, SAF < Rotary ProTaper. Conclusions: Apical extrusion of debris was invariably present in all the instrumentation systems analyzed. SAF system seemed to be periapical tissue friendly as it caused reduced apical extrusion compared to Rotary ProTaper and Wave One. PMID:28761250
Yazdizadeh, Mohammad; Skini, Masoumeh; Hoseini Goosheh, Seyyed Mohsen; Jafarzadeh, Mansour; Shamohammadi, Milad; Rakhshan, Vahid
2017-01-01
Introduction: Cyclic fatigue is the common reason for breakage of rotary instruments. This study was conducted to evaluate the effect of cryogenic treatment (CT) in improving the resistance to cyclic fatigue of endodontic rotary instruments. Methods and Materials: In this in vitro study, 20 RaCe and 20 Mtwo files were randomly divided into two groups of negative control and CT. CT files were stored in liquid nitrogen at -196°C for 24 h, and then were gradually warmed to the room temperature. All files were used (at torques and speeds recommended by their manufacturers) in a simulated canal with a 45° curvature until breakage. The time to fail (TF) was recorded and used to calculate the number of cycle to fail (NCF). Groups were compared using independent-samples t-test. Results: Mean NCFs were 1248.2±68.1, 1281.6±78.6, 4126.0±179.2, and 4175.4±190.1 cycles, for the Mtwo-control, Mtwo-CT, RaCe-control, and RaCe-CT, respectively. The difference between the controls and their respective CT groups were not significant (P>0.3). The difference between the systems was significant. Conclusion: Deep CT did not improve resistance to cyclic fatigue of the evaluated rotary files. PMID:28512489
Preparatory Test for First Rock Drilling by Mars Rover Curiosity
2013-02-04
The bit in the rotary-percussion drill of NASA Mars rover Curiosity left its mark in a target patch of rock called John Klein during a test on Feb. 2, 2013, in preparation for the first drilling of a rock by the rover.
Neelakantan, P; Khan, K; Li, K Y; Shetty, H; Xi, W
2018-07-01
To examine the efficacy of a novel supplementary irrigant agitating brush (Finisher GF Brush, MedicNRG, Kibbutz Afikim, Israel) on the debridement of root canals prepared with a novel stainless steel rotary instrumentation system (Gentlefile; MedicNRG), or nickel titanium rotary instruments in oval root canals. Mandibular premolars (n = 72) were selected and divided randomly into three experimental groups (n = 24) after microCT scanning: group 1, canal preparation to rotary NiTi size 20, .04 taper (R20); group 2, rotary NiTi to size 25, .04 taper (R25) and group 3, Gentlefile size 23, .04 taper (GF). Specimens were subdivided into two subgroups: subgroup A, syringe-and-needle irrigation (SNI); subgroup B, Finisher GF Brush (GB). Ten untreated canals served as controls. Specimens were processed for histological evaluation, and the remaining pulp tissue (RPT) was measured. Data were analysed using Mann-Whitney and Kruskal-Wallis tests (P = 0.05). All experimental groups had significantly less RPT than the control (P < 0.05). Group 3B (GF-GB) had significantly less RPT than groups 1B (R20-GB) and 2B (R25-GF; P < 0.05). When irrigated with SNI, there was no significant difference in the RPT between the three groups (P > 0.05). When instrumented with R20, there was no significant difference between SNI and GF (P < 0.05) whilst GB had significantly less RPT than SNI for R25 (P < 0.05). Supplementary irrigant agitation with the Finisher GF Brush improved the debridement of canals prepared with Gentlefile and size 25, .04 taper rotary NiTi. Root canal debridement did not significantly differ between the instruments when syringe irrigation was used. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.
[Engine-driven preparation of curved root canals: a platform to assess physical parameters].
Peters, O A; Kappeler, S; Bucher, W; Barbakow, F
2001-01-01
The number of engine-driven rotary instruments available on the market is steadily increasing. These instruments enable clinicians to prepare better shaped root canals, however, rotary instruments have a higher risk for fracture than hand instruments. Unfortunately, the stresses placed on engine-driven rotary instruments in curved canals are insufficiently studied. The aim of this study was to develop a device which could measure more accurately the physical parameters influencing rotary instruments in curved canals. For this purpose, a specially designed machine was constructed to measure the torque which develops between the rotary instrument and the motor. Apical forces and penetration depths could also be directly measured in real time. A variety of other measurements was also possible because of other special set-ups integrated into the device. In the current study torque was assessed for GT-Files, size 35 with a .12 and sizes 20 with a .12 to .06 taper. In additions to preparations in simulated canals in plastic blocks, the "ISO 3630-1 specification for fracture moment" and "number of cycles till fatigue fracture" was measured. The findings indicated that when instruments were used for preparations, torques up to 40 Nmm were present. This exceeded the static fracture load, which was less than than 13 Nmm for the size 20 with .12 taper. In contrast, the number of rotations were more than 10 times lower when shaping canals in plastic blocks with a 5 mm radius of curvature than the number of rotations to fracture in the "cyclic fatigue test". This suggests that a GT-instrument could be used in ten canals. The apical force was always greater than 1 N and occasionally, 8 N or more was recorded. Further studies on natural teeth with varying canal geometries are required using the specially developed torsional machine to reduce the incidence of instrument fracture. In this way an efficient clinical potential can be confirmed for engine-driven rotary instruments in canal preparation.
de Carvalho, Fredson Marcio Acris; Gonçalves, Leonardo Cantanhede de Oliveira; Marques, André Augusto Franco; Alves, Vanessa; Bueno, Carlos Eduardo da Silveira; De Martin, Alexandre Sigrist
2016-01-01
To compare cleaning effectiveness by histological analysis of a reciprocating single-file system with ProTaper rotary instruments during the preparation of curved root canals in extracted teeth. A total of 40 root canals with curvatures ranging between 20 - 40 degrees were divided into two groups of 20 canals. Canals were prepared to the following apical sizes: Reciproc size 25 (n=20); ProTaper: F2 (n=20). The normal distribution of data was tested by the Kolmogorov-Smirnov test and the values obtained for the test (Mann-Whitney U test, P < .05) were statistically analyzed using the GraphPad InStat for the Mac OS software (GraphPad Software, La Jolla, CA, USA). There were no significant differences in remaining debris (P > .05) between the two groups. The application of reciprocating motion during instrumentation did not result in increased debris when compared with continuous rotation motion, even in the apical part of curved canals. Both instruments resulted in debris in the canal lumen, irrespective of the movement kinematics applied.
A Flight Dynamic Model of Aircraft Spinning
1990-06-01
r Zaw rate about body axes S Aircraft wing area V Flight path velocity 3 a Angle of attack Sideslip angle 6, Aileron deflection, positive when right...Tests, May/June 1983 PartI. Unpublished data report. 6. MARTIN, C.A. and SECOMB, D.A. ; RAAF BPTA Phase II Wind Tun - nel Tests: Rotary Balance Tests
Root-canal shaping with manual and rotary Ni-Ti files performed by students.
Sonntag, D; Delschen, S; Stachniss, V
2003-11-01
To investigate root-canal shaping with manual and rotary Ni-Ti files performed by students. Thirty undergraduate dental students prepared 150 simulated curved root canals in resin blocks with manual Ni-Ti files with a stepback technique and 450 simulated curved canals with rotary Ni-Ti files with a crowndown technique. Incidence of fracture, preparation length, canal shape and preparation time were investigated. Questionnaires were then issued to the students for them to note their experience of the two preparation methods. Zips and elbows occurred significantly (P < 0.001) less frequently with rotary than with manual preparation. The correct preparation length was achieved significantly (P < 0.05) more often with rotary files than with manual files. Instrument fractures were recorded in only 1.3% of cases with both rotary and manual preparation. The mean time required for manual preparation was significantly (P < 0.001) longer than that required for rotary preparation. Prior experience with a hand preparation technique was not reflected in an improved quality of the subsequent rotary preparation. Approximately 83% of the students claimed to have a greater sense of security in rotary than in manual preparation. Overall 50% felt that manual and engine-driven preparation should be given equal status in undergraduate dental education. Inexperienced operators achieved better canal preparations with rotary instruments than with manual files. No difference in fracture rate was recorded between the two systems.
16 CFR 1205.5 - Walk-behind rotary power mower controls.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Walk-behind rotary power mower controls... rotary power mower controls. (a) Blade control systems—(1) Requirements for blade control. A walk-behind rotary power mower shall have a blade control system that will perform the following functions: (i...
Joseph, Mercy; Malhotra, Amit; Rao, Murali; Sharma, Abhimanyu; Talwar, Sangeeta
2016-01-01
Background Complete removal of old filling material during root canal retreatment is fundamental for predictable cleaning and shaping of canal anatomy. Most of the retreatment methods tested in earlier studies have shown inability to achieve complete removal of root canal filling. Therefore the aim of this investigation was to assess the efficacy of three different rotary nickel titanium retreatment systems and Hedstrom files in removing filling material from root canals. Material and Methods Sixty extracted mandibular premolars were decoronated to leave 15 mm root. Specimen were hand instrumented and obturated using gutta percha and AH plus root canal sealer. After storage period of two weeks, roots were retreated with three (Protaper retreatment files, Mtwo retreatment files, NRT GPR) rotary retreatment instrument systems and Hedstroem files. Subsequently, samples were sectioned longitudinally and examined under stereomicroscope. Digital images were recorded and evaluated using Digital Image Analysing Software. The retreatment time was recorded for each tooth using a stopwatch. The area of canal and the residual filling material was recorded in mm2 and the percentage of remaining filling material on canal walls was calculated. Data was analysed using ANOVA test. Results Significantly less amount of residual filling material was present in protaper and Mtwo instrumented teeth (p < 0.05) compared to NRT GPR and Hedstrom files group. Protaper instruments also required lesser time during removal of filling material followed by Mtwo instruments, NRT GPR files and Hedstrom files. Conclusions None of the instruments were able to remove the filling material completely from root canal. Protaper universal retreatment system and Mtwo retreatment files were more efficient and faster compared to NRT GPR fles and Hedstrom files. Key words:Gutta-percha removal, nickel titanium, root canal retreatment, rotary instruments. PMID:27703601
Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software
GIANNASTASIO, Daiana; da ROSA, Ricardo Abreu; PERES, Bernardo Urbanetto; BARRETO, Mirela Sangoi; DOTTO, Gustavo Nogara; KUGA, Milton Carlos; PEREIRA, Jefferson Ricardo; SÓ, Marcus Vinícius Reis
2013-01-01
Objective This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. Material and Methods Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. Results The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). Conclusion Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop. PMID:24212994
Wizard CD Plus and ProTaper Universal: analysis of apical transportation using new software.
Giannastasio, Daiana; Rosa, Ricardo Abreu da; Peres, Bernardo Urbanetto; Barreto, Mirela Sangoi; Dotto, Gustavo Nogara; Kuga, Milton Carlos; Pereira, Jefferson Ricardo; Só, Marcus Vinícius Reis
2013-01-01
This study has two aims: 1) to evaluate the apical transportation of the Wizard CD Plus and ProTaper Universal after preparation of simulated root canals; 2) to compare, with Adobe Photoshop, the ability of a new software (Regeemy) in superposing and subtracting images. Twenty five simulated root canals in acrylic-resin blocks (with 20º curvature) underwent cone beam computed tomography before and after preparation with the rotary systems (70 kVp, 4 mA, 10 s and with the 8×8 cm FoV selection). Canals were prepared up to F2 (ProTaper) and 24.04 (Wizard CD Plus) instruments and the working length was established to 15 mm. The tomographic images were imported into iCAT Vision software and CorelDraw for standardization. The superposition of pre- and post-instrumentation images from both systems was performed using Regeemy and Adobe Photoshop. The apical transportation was measured in millimetres using Image J. Five acrylic resin blocks were used to validate the superposition achieved by the software. Student's t-test for independent samples was used to evaluate the apical transportation achieved by the rotary systems using each software individually. Student's t-test for paired samples was used to compare the ability of each software in superposing and subtracting images from one rotary system per time. The values obtained with Regeemy and Adobe Photoshop were similar to rotary systems (P>0.05). ProTaper Universal and Wizard CD Plus promoted similar apical transportation regardless of the software used for image's superposition and subtraction (P>0.05). Wizard CD Plus and ProTaper Universal promoted little apical transportation. Regeemy consists in a feasible software to superpose and subtract images and appears to be an alternative to Adobe Photoshop.
Rotary Drum Separator and Pump for the Sabatier Carbon Dioxide Reduction System
NASA Technical Reports Server (NTRS)
Holder, Don; Fort, James; Barone, Michael; Murdoch, Karen
2005-01-01
A trade study conducted in 2001 selected a rotary disk separator as the best candidate to meet the requirements for an International Space Station (ISS) Carbon Dioxide Reduction Assembly (CRA). The selected technology must provide micro-gravity gasfliquid separation and pump the liquid from 10 psia at the gasfliquid interface to 18 psia at the wastewater bus storage tank. The rotary disk concept, which has pedigree in other systems currently being built for installation on the ISS, failed to achieve the required pumping head within the allotted power. The separator discussed in this paper is a new design that was tested to determine compliance with performance requirements in the CRA. The drum separator and pump @SP) design is similar to the Oxygen Generator Assembly (OGA) Rotary Separator Accumulator (RSA) in that it has a rotating assembly inside a stationary housing driven by a integral internal motor. The innovation of the DSP is the drum shaped rotating assembly that acts as the accumulator and also pumps the liquid at much less power than its predecessors. In the CRA application, the separator will rotate at slow speed while accumulating water. Once full, the separator will increase speed to generate sufficient head to pump the water to the wastewater bus. A proof-of- concept (POC) separator has been designed, fabricated and tested to assess the separation efficiency and pumping head of the design. This proof-of-concept item was flown aboard the KC135 to evaluate the effectiveness of the separator in a microgravity environment. This separator design has exceeded all of the performance requirements. The next step in the separator development is to integrate it into the Sabatier Carbon Dioxide Reduction System. This will be done with the Sabatier Engineering Development Unit at the Johnson Space Center.
The Effect of Electrical Treatment on Cyclic Fatigue of NiTi Instruments
Saghiri, Mohammad Ali; Asatourian, Armen; Garcia-Godoy, Franklin; Gutmann, James L.; Lotfi, Mehrdad; Sheibani, Nader
2016-01-01
Summary Dentists desire to use NiTi rotary instruments, which do not break inside the root canals of teeth, since the pieces from broken files are difficult to remove. The NiTi rotary instrument breakage is because of cyclic and torsional fatigue. Here the low-voltage (12 V) and high voltage (24 V) electrical treatments were used to enhance the cyclic fatigue of NiTi rotary instruments and increase their durability. In excremental groups, following electrical treatment samples of the NiTi instruments were rotated inside artificial root canals until they broke. Our results showed that electrical treatment with 12-V DC was effective in restoring NiTi instrument’s resistance to cyclic fatigue. The scanning electron microscopy images and fractograph of samples exposed to 12-V electrical treatment showed a more regular texture over the surface with less dimpling on fractured site. These patterns can improve the super elasticity of tested devices during rotational movement, and delay the NiTi instruments separation in root canal preparations. PMID:24798116
Gambarini, Gianlucca; Gergi, Richard; Grande, Nicola Maria; Osta, Nada; Plotino, Gianluca; Testarelli, Luca
2013-12-01
The aim of this study was to investigate whether cyclic fatigue resistance is increased for nickel titanium instruments manufactured with improved heating processes in clockwise or counterclockwise continuous rotation. The instruments compared were produced either using the R-phase heat treatment (K3XF; SybronEndo, Orange, CA, USA) or the M-wire alloy (ProFile Vortex; DENTSPLY Tulsa Dental Specialties, Tulsa, OK, USA). Tests were performed with a specific cyclic fatigue device that evaluated cycles to failure of rotary instruments in curved artificial canals. Results indicated no significant difference in resistance to cyclic fatigue when rotary nickel titanium instruments are used in clockwise or counterclockwise continuous rotation. In both directions of rotation, size 04-25 K3XF showed a significant increase (P < 0.05) in the mean number of cycles to failure when compared with size 04-25 ProFile Vortex. © 2012 The Authors. Australian Endodontic Journal © 2012 Australian Society of Endodontology.
Membrane fouling control using a rotary disk in a submerged anaerobic membrane sponge bioreactor.
Kim, Jungmin; Shin, Jaewon; Kim, Hyemin; Lee, Jung-Yeol; Yoon, Min-Hyuk; Won, Seyeon; Lee, Byung-Chan; Song, Kyung Guen
2014-11-01
Despite significant research efforts over the last few decades, membrane fouling in anaerobic membrane bioreactors (AnMBRs) remains an unsolved problem that increases the overall operational costs and obstructs the industrial applications. Herein, we developed a method for effectively controlling the membrane fouling in a sponge-submerged AnMBRs using an anaerobic rotary disk MBR (ARMBR). The disk rotation led the effective collision between the sponge and membrane surface; thus successfully enhanced the membrane permeability in the ARMBR. The effect of the disk rotational speed and sponge volume fraction on the membrane permeability and the relationship between the water flow direction and membrane permeability were investigated. The long-term feasibility was tested over 100days of synthetic wastewater treatment. As a result, stable and economical performance was observed without membrane replacement and washing. The proposed integrated rotary disk-supporting media appears to be a feasible and even beneficial option in the AnMBR technology. Copyright © 2014 Elsevier Ltd. All rights reserved.
Cyclic fatigue of nickel-titanium rotary instruments in a double (S-shaped) simulated curvature.
Al-Sudani, Dina; Grande, Nicola M; Plotino, Gianluca; Pompa, Giorgio; Di Carlo, Stefano; Testarelli, Luca; Gambarini, Gianluca
2012-07-01
The goal of the present study was to test the fatigue resistance of nickel-titanium rotary files in a double curvature (S-shaped) artificial root canal and to compare those results with single curvature artificial root canals. Two nickel-titanium endodontic instruments consisting of identical instrument sizes (constant .06 taper and 0.25 tip diameter) were tested, ProFile instruments and Vortex instruments. Both instruments were tested for fatigue inside an artificial canal with a double curvature and inside a curved artificial canal with a single curvature. Ten instruments for each group were tested to fracture in continuous rotary motion at 300 rpm. Number of cycles to failure (NCF) was calculated to the nearest whole number, and the length of the fractured fragment was measured in millimeters. Data were statistically analyzed with a level of significance set at 95% confidence level. The NCF value was always statistically lower in the double curved artificial canal when compared with the single curve (P < .05) in both the apical and coronal curvatures. Statistically significant differences (P < .05) were noted between instruments of the same size of different brand only in the single curve; ProFile registered a mean of 633.5 ± 75.1 NCF, whereas Vortex registered a mean of 548 ± 48.9 NCF. Regardless of the differences between the instruments used in the present study, the results suggest that the more complex is the root canal, the more adverse are the effects on the cyclic fatigue resistance of the instruments. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Harandi, Azadeh; Mirzaeerad, Sina; Mehrabani, Mahgol; Mahmoudi, Elham; Bijani, Ali
2017-01-01
Introduction: This study aimed to compare the incidence of dentinal crack formation by instrumentation with ProTaper Universal system (rotary, multi-file system), SafeSider (reciprocation movement, multi-file system) and Neolix (rotary, single-file system). Methods and Materials: In this in vitro study, 60 freshly extracted mandibular first molars were randomly divided into three experimental groups (n=15) and a control group containing unprepared teeth (n=15). Instrumentation in different groups was accomplished using either ProTaper, Neolix or SafeSider systems up to 25/0.08. The teeth were then sectioned at 3, 6 and 9 mm from the apex, and observed under a stereomicroscope for presence of dentinal cracks. Data were analyzed with Chi square test, Fisher’s exact test and Bonferroni correction. Results: Micro cracks were seen in all experimental groups (13.3% in ProTaper, 26.7% in SafeSider and 40% in Neolix). There was a significant difference between Neolix and the control groups in microcrack formation (P=0.042). Micro cracks mainly occurred in the coronal section (9 mm). No microcrack occurred in the control group. Conclusion: Neolix rotary single-file system caused more dentinal cracks compared to the unprepared roots. All the instrumentation systems increased the number of micro cracks compared to unprepared teeth. PMID:29225637
Lopes, Hélio Pereira; Chiesa, Wanderson Miguel Maia; Correia, Norbi Rodrigues; de Souza Navegante, Núbia Carvalho; Elias, Carlos Nelson; Moreira, Edson Jorge Lima; Chiesa, Bianca Esther Cabral
2011-06-01
This study evaluated the effects of curvature location along an artificial canal on cyclic fatigue (CF) of an Mtwo rotary instrument, verifying the number of cycles to fatigue fracture (NCF) and morphologic characteristics of the fractured instruments. CF testing of instruments was performed in artificial canals with curvature radii of 10 mm and arc lengths of 11 mm. Mtwo rotary instruments size 40, 0.04 taper were used in 2 groups (n = 10): group A, curvature positioned on middle part; group B, apical curvature. All instruments were rotated until fracture. The number of cycles to failure was registered. Data were analyzed by independent sample t test. Fractured surfaces and the helical shafts of the instruments were analyzed by scanning electron microscopy. NCF for groups A and B had significant statistic differences (P < .05). The highest values were found in the group where the curvature was positioned on the apical part of the canal. No plastic deformation was observed on the helical shafts. The number of cycles to fracture of the Mtwo instruments increased when the arc was changed from the middle to the apical part of the canal. The morphologic characteristics of the fractured surfaces were of the ductile type. Copyright © 2011 Mosby, Inc. All rights reserved.
Highly precise and compact ultrahigh vacuum rotary feedthrough.
Aiura, Y; Kitano, K
2012-03-01
The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.
Highly precise and compact ultrahigh vacuum rotary feedthrough
NASA Astrophysics Data System (ADS)
Aiura, Y.; Kitano, K.
2012-03-01
The precision and rigidity of compact ultrahigh vacuum (UHV) rotary feedthroughs were substantially improved by preparing and installing an optimal crossed roller bearing with mounting holes. Since there are mounting holes on both the outer and inner races, the bearing can be mounted directly to rotary and stationary stages without any fixing plates and housing. As a result, it is possible to increase the thickness of the bearing or the size of the rolling elements in the bearing without increasing the distance between the rotating and fixing International Conflat flanges of the UHV rotary feedthrough. Larger rolling elements enhance the rigidity of the UHV rotary feedthrough. Moreover, owing to the structure having integrated inner and outer races and mounting holes, the performance is almost entirely unaffected by the installation of the bearing, allowing for a precise optical encoder to be installed in the compact UHV rotary feedthrough. Using position feedback via a worm gear system driven by a stepper motor and a precise rotary encoder, the actual angle of the compact UHV rotary feedthrough can be controlled with extremely high precision.
Matwychuk, Michael J; Bowles, Walter R; McClanahan, Scott B; Hodges, Jim S; Pesun, Igor J
2007-07-01
The purpose of this study was to compare apical transportation, working-length changes, and instrumentation time by using nickel-titanium (Ni-Ti) rotary file systems (crown-down method) or stainless steel hand files (balanced-force technique) in mesiobuccal canals of extracted mandibular molars. The curvature of each canal was determined and teeth placed into three equivalent groups. Group 1 was instrumented with Sequence (Brasseler USA, Savannah, GA) rotary files, group 2 with Liberator (Miltex Inc, York, PA) rotary files, and group 3 with Flex-R (Union Broach, New York, NY) files. Pre- and postoperative radiographs were superimposed to measure loss of working length and apical transportation as shown by changes in radius of curvature and the long-axis canal angle. Sequence rotary files, Liberator rotary files, and Flex-R hand files had similar effects on apical canal transportation and changes in working length, with no significant differences detected among the 3 groups. Hand instrumentation times were longer than with either Ni-Ti rotary group, whereas the rotary NiTi groups had a higher incidence of fracture.
DOE Office of Scientific and Technical Information (OSTI.GOV)
TerraTek, A Schlumberger Company
2008-12-31
The two phase program addresses long-term developments in deep well and hard rock drilling. TerraTek believes that significant improvements in drilling deep hard rock will be obtained by applying ultra-high rotational speeds (greater than 10,000 rpm). The work includes a feasibility of concept research effort aimed at development that will ultimately result in the ability to reliably drill 'faster and deeper' possibly with smaller, more mobile rigs. The principle focus is on demonstration testing of diamond bits rotating at speeds in excess of 10,000 rpm to achieve high rate of penetration (ROP) rock cutting with substantially lower inputs of energymore » and loads. The significance of the 'ultra-high rotary speed drilling system' is the ability to drill into rock at very low weights on bit and possibly lower energy levels. The drilling and coring industry today does not practice this technology. The highest rotary speed systems in oil field and mining drilling and coring today run less than 10,000 rpm - usually well below 5,000 rpm. This document provides the progress through two phases of the program entitled 'Smaller Footprint Drilling System for Deep and Hard Rock Environments: Feasibility of Ultra-High-Speed Diamond Drilling' for the period starting 30 June 2003 and concluding 31 March 2009. The accomplishments of Phases 1 and 2 are summarized as follows: (1) TerraTek reviewed applicable literature and documentation and convened a project kick-off meeting with Industry Advisors in attendance (see Black and Judzis); (2) TerraTek designed and planned Phase I bench scale experiments (See Black and Judzis). Improvements were made to the loading mechanism and the rotational speed monitoring instrumentation. New drill bit designs were developed to provided a more consistent product with consistent performance. A test matrix for the final core bit testing program was completed; (3) TerraTek concluded small-scale cutting performance tests; (4) Analysis of Phase 1 data indicated that there is decreased specific energy as the rotational speed increases; (5) Technology transfer, as part of Phase 1, was accomplished with technical presentations to the industry (see Judzis, Boucher, McCammon, and Black); (6) TerraTek prepared a design concept for the high speed drilling test stand, which was planned around the proposed high speed mud motor concept. Alternative drives for the test stand were explored; a high speed hydraulic motor concept was finally used; (7) The high speed system was modified to accommodate larger drill bits than originally planned; (8) Prototype mud turbine motors and the high speed test stand were used to drive the drill bits at high speed; (9) Three different rock types were used during the testing: Sierra White granite, Crab Orchard sandstone, and Colton sandstone. The drill bits used included diamond impregnated bits, a polycrystalline diamond compact (PDC) bit, a thermally stable PDC (TSP) bit, and a hybrid TSP and natural diamond bit; and (10) The drill bits were run at rotary speeds up to 5500 rpm and weight on bit (WOB) to 8000 lbf. During Phase 2, the ROP as measured in depth of cut per bit revolution generally increased with increased WOB. The performance was mixed with increased rotary speed, with the depth cut with the impregnated drill bit generally increasing and the TSP and hybrid TSP drill bits generally decreasing. The ROP in ft/hr generally increased with all bits with increased WOB and rotary speed. The mechanical specific energy generally improved (decreased) with increased WOB and was mixed with increased rotary speed.« less
INITIAL ASSESSMENT OF SURFACE PRESSURE CHARACTERISTICS OF TWO ROTARY WING UAV DESIGNS
NASA Technical Reports Server (NTRS)
Jones, Henry E.; Wong, Oliver D.; Watkins, A. Neal; Noonan, Kevin W.; Reis, Deane G.; Malovrh, Brendon D.; Ingram, Joanne L.
2006-01-01
This paper presents results of an experimental investigation of two rotary-wing UAV designs. The primary goal of the investigation was to provide a set of interactional aerodynamic data for an emerging class of rotorcraft. The present paper provides an overview of the test and an introduction to the test articles, and instrumentation. Sample data in the form of fixed system pressure coefficient response to changes in configuration attitude and flight condition for both rotor off and on conditions are presented. The presence of the rotor is seen to greatly affect the magnitude of the response. Pressure coefficients were measured using both conventional pressure taps and via pressure sensitive paint. Comparisons between the two methods are presented and demonstrate that the pressure sensitive paint is a promising method; however, further work on the technique is required.
High Detent Torque Rotary Actuator Development
NASA Astrophysics Data System (ADS)
Santos, I.; Sainz, I.; Allegranza, C.
2015-09-01
In the frame of an ESA ARTES 5 Contract, SENER has performed the design, manufacturing and testing at component and mechanism levels of a High Detent Torque Rotary Actuator (DTA in short), i.e. with high capability to hold a payload when unpowered.Two configurations were developed to allow the use on specific application flight opportunity; both are identical in terms of architecture, lubrication, structural and thermal design. The exception is the angular position sensor type: the DTA 100 with contactless sensors and the DTA 120 with potentiometers.The DTA is a fully european technology. This paper provides a synthesis of the obtained parameters in front of the requirements, the evolution from the initial concept to the final configuration and the results of the extensive test campaign (DTA 120). Lessons learned and the readiness for use at upper level are also highlighted.
Percussive Augmenter of Rotary Drills (PARoD)
NASA Technical Reports Server (NTRS)
Badescu, Mircea; Hasenoehrl, Jennifer; Bar-Cohen, Yoseph; Sherrit, Stewart; Bao, Xiaoqi; Chang, Zensheu; Ostlund, Patrick; Aldrich, Jack
2013-01-01
Increasingly, NASA exploration mission objectives include sample acquisition tasks for in-situ analysis or for potential sample return to Earth. To address the requirements for samplers that could be operated at the conditions of the various bodies in the solar system, a piezoelectric actuated percussive sampling device was developed that requires low preload (as low as 10 N) which is important for operation at low gravity. This device can be made as light as 400 g, can be operated using low average power, and can drill rocks as hard as basalt. Significant improvement of the penetration rate was achieved by augmenting the hammering action by rotation and use of a fluted bit to provide effective cuttings removal. Generally, hammering is effective in fracturing drilled media while rotation of fluted bits is effective in cuttings removal. To benefit from these two actions, a novel configuration of a percussive mechanism was developed to produce an augmenter of rotary drills. The device was called Percussive Augmenter of Rotary Drills (PARoD). A breadboard PARoD was developed with a 6.4 mm (0.25 in) diameter bit and was demonstrated to increase the drilling rate of rotation alone by 1.5 to over 10 times. The test results of this configuration were published in a previous publication. Further, a larger PARoD breadboard with a 50.8 mm (2.0 in) diameter bit was developed and tested. This paper presents the design, analysis and test results of the large diameter bit percussive augmenter.
The primary objective of these tests was to demonstrate the effectiveness of incineration as a decontamination method for explosives contaminated sails. A pilot-scale rotary kiln incinerator, manufactured by ThermAll, Inc., was used to treat both sandy and clayey...
40 CFR 63.1384 - Performance test requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... parameter. (3) During each performance test, the owner or operator must monitor and record the glass pull rate for each glass-melting furnace and, if different, the glass pull rate for each rotary spin manufacturing line and flame attenuation manufacturing line. Record the glass pull rate every 15 minutes during...
40 CFR 63.1384 - Performance test requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... parameter. (3) During each performance test, the owner or operator must monitor and record the glass pull rate for each glass-melting furnace and, if different, the glass pull rate for each rotary spin manufacturing line and flame attenuation manufacturing line. Record the glass pull rate every 15 minutes during...
NASA Technical Reports Server (NTRS)
Ralston, J. N.; Barnhart, B. P.
1984-01-01
The influence of control deflections on the rotational flow aerodynamics and on predicted spin modes is discussed for a 1/6-scale general aviation airplane model. The model was tested for various control settings at both zero and ten degree sideslip angles. Data were measured, using a rotary balance, over an angle-of-attack range of 30 deg to 90 deg, and for clockwise and counter-clockwise rotations covering an omegab/2V range of 0 to 0.5.
NASA Technical Reports Server (NTRS)
Barnhart, B.
1982-01-01
The influence of horizontal tail location on the rotational flow aerodynamics is discussed for a 1/6-scale general aviation airplane model. The model was tested using various horizontal tail positions, with both a high and a low-wing location and for each of two body lengths. Data were measured, using a rotary balance, over an angle-of-attack range of 8 to 90 deg, and for clockwise and counter-clockwise rotations covering an Omega b/2V range of 0 to 0.9.
NASA Technical Reports Server (NTRS)
Hultberg, R. S.; Chu, J.
1980-01-01
Aerodynamic characteristics obtained in a helical flow environment utilizing a rotary balance located in the Langley spin g tunnel are presented in plotted form for a 1/6 scale, single engine, high wing, general aviation model. The configurations tested included the basic airplane and control deflections, wing leading edge devices, tail designs, and airplane components. Data are presented without analysis for an angle of attack range of 8 deg to 90 deg and clockwise and counter clockwise rotations covering a spin coefficient range from 0 to 0.9.
Wei, Zhao; Cui, Zhi; Yan, Ping; Jiang, Han
2017-01-09
Micro-CT (μCT) studies that combine simulated canals with meglucamine diatrizoate to evaluate the shaping ability of nickel-titanium (NiTi) rotary instruments are lacking in the literature. The purpose of this study was to evaluate the shaping ability of three new different nickel-titanium rotary instruments in simulated root canals using μCT. Thirty simulated root canals with a curvature of 60° were randomly allocated into the following 3 groups (n = 10): Group 1, ProTaper Universal (PTU) rotary system; Group 2, Reciproc single-file system; and Group 3, K3XF rotary system. Pre- and post-instrumented images of simulated canals were scanned with μCT via a radiopaque contrast technique to build a 3-dimensional (3D) model. Canal transportation, volumetric change and centring ability were evaluated in each group. Instrument failure and preparation time were also recorded. The Kruskal-Wallis test was used for statistical analysis and the significance level was set at p = 0.05. Reciproc produced greater volume change in the apical part of the canals compared with PTU and K3XF (p < 0.05). K3XF exhibited less transportation and better centring ability at the 2- and 3-mm levels from the apical foramen compared with PTU and Reciproc (p < 0.05). There were no significant differences in the centring ratio and transportation between PTU and Reciproc. Preparation time was significantly shorter in the Reciproc group (p < 0.05). Under the conditions of our study, all of the canals were 3D reconstructed successfully via the radiopaque contrast technique. Reciproc showed enhanced apical volume changes and K3XF exhibited better centring ability when compared with other groups.
Martinho, Frederico C; Gomes, Ana P M; Fernandes, Aletéia M M; Ferreira, Nádia S; Endo, Marcos S; Freitas, Lilian F; Camões, Izabel C G
2014-05-01
This clinical study was conducted to compare the effectiveness of single-file reciprocating systems and rotary systems in removing endotoxins and cultivable bacteria from primarily infected root canals. Forty-eight primarily infected root canals were selected and randomly divided into 4 groups: WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) (n = 12); Reciproc (VDW, Munich, Germany) (n = 12), ProTaper (Dentsply Maillefer) (n = 12), and Mtwo (VDW) (n = 12). Samples were collected before and after chemomechanical preparation. The irrigation was performed by using 2.5% sodium hypochlorite. A chromogenic limulus amebocyte lysate assay test was used to quantify endotoxins. Culture techniques were used to determine bacterial colony-forming unit counts. In the baseline samples (ie, samples collected before chemomechanical preparation), endotoxins and cultivable bacteria were recovered from 100% of the root canal samples. No differences were found in the median percentage values of endotoxin reduction achieved with reciprocating systems (ie, WaveOne [95.15%] and Reciproc [96.21%]) and with rotary systems (ie, ProTaper [97.98%] and Mtwo [96.34%]) (P < .05). Both single-file reciprocating systems (ie, WaveOne [99.45%] and Reciproc [99.93%]) and rotary systems (ProTaper [99.85%] and Mtwo [99.41%]) were effective in reducing the cultivable bacteria (all P < .05). Moreover, the culture analysis revealed no differences in bacterial load reduction (P > .05). Both single-file reciprocating systems (ie, WaveOne and Reciproc instruments) and rotary systems (ie, ProTaper and Mtwo instruments) showed similar effectiveness in reducing endotoxins and cultivable bacteria from primarily infected root canals, but they were not able to eliminate them from all root canals analyzed. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Zink rotary kiln seal: Cam followers. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fisher, D.L.
1994-12-09
The CIF will treat hazardous and mixed low-level radioactive waste in a rotary kiln and secondary combustion chamber. A high efficiency air pollution control system follows the secondary chamber. The rotary kiln is designed with a gas seal at each end of its rotating barrel which provides a barrier between the interior of the kiln and outside air. The internal pressure of the rotary kiln will be maintained below atmospheric pressure, so exterior air passing the seals is forced into the kiln`s interior. Positive pressure may be applied in the seal labyrinth, adding a barrier to flow. Both CIF sealsmore » will be covered entirely with exhaust hoods, drawing air over the outside of the seal and into a HEPA filtered exhaust system. Cam follower misalignment on a John Zink rotary kiln seal caused damage to the seal`s rotor. The misalignment was quantified, corrected, and checked to verify straightness. The primary purpose of the correction was to allow seal testing 1 to continue, but the information is applicable to the Consolidated Incineration Facility (CIF) since two large seals of similar design will be installed there. Cam follower straightness was off as much as 3.5{degrees}, causing followers to run untrue on the rotor. High contact forces resulted, removing flakes of metal from the rotor surface. The misalignment caused weight bearing followers on one side of the seal to back out of their threaded mounts. The root cause was poor machining of the follower mounting holes. Correction was accomplished by relieving the holes and installing machined spacers and retaining nuts. Cam followers on the CIF`s Zink seals should be inspected for straightness before the seals are installed.« less
Zarei, Mina; Javidi, Maryam; Erfanian, Mahdi; Lomee, Mahdi; Afkhami, Farzaneh
2013-01-01
Cleaning and shaping is one of the most important phases in root canal therapy. Various rotary NiTi systems minimize accidents and facilitate the shaping process. Todays NiTi files are used with air-driven and electric handpieces. This study compared the canal centering after instrumentation using the ProTaper system using Endo IT, electric torque-control motor, and NSK air-driven handpiece. This ex vivo randomized controlled trial study involved 26 mesial mandibular root canals with 10 to 35° curvature. The roots were randomly divided into 2 groups of 13 canals each. The roots were mounted in an endodontic cube with acrylic resin, sectioned horizontally at 2, 6 and 10 mm from the apex and then reassembled. The canals were instrumented according to the manufacturer's instructions using ProTaper rotary files and electric torque-control motors (group 1) or air-driven handpieces (group 2). Photographs of the cross-sections included shots before and after instrumentation, and image analysis was performed using Photoshop software. The centering ability and canal transportation was also evaluated. Repeated measurement and independent t-test provided statistical analysis of canal transportation. The comparison of the rate of transportation toward internal or external walls between the two groups was not statistically significant (p = 0.62). Comparison of the rate of transportation of sections within one group was not significant (p = 0.28). Use of rotary NiTi file with either electric torquecontrol motor or air-driven handpiece had no effect on canal centering. NiTi rotary instruments can be used with air-driven motors without any considerable changes in root canal anatomy, however it needs the clinician to be expert.
Code of Federal Regulations, 2010 CFR
2010-07-01
... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Rotary Jet Piercing § 56.7804 Refueling. When rotary jet piercing equipment requires refueling at...
Code of Federal Regulations, 2011 CFR
2011-07-01
... HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Rotary Jet Piercing § 56.7804 Refueling. When rotary jet piercing equipment requires refueling at...
Code of Federal Regulations, 2010 CFR
2010-07-01
... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7804 Refueling. When rotary jet piercing equipment requires...
Code of Federal Regulations, 2011 CFR
2011-07-01
... HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Drilling and Rotary Jet Piercing Rotary Jet Piercing-Surface Only § 57.7804 Refueling. When rotary jet piercing equipment requires...
Root canal shaping with manual stainless steel files and rotary Ni-Ti files performed by students.
Sonntag, D; Guntermann, A; Kim, S K; Stachniss, V
2003-04-01
To investigate root canal shaping with manual stainless steel files and rotary Ni-Ti files by students. Two hundred and ten simulated root canals with the same geometrical shape and size in acrylic resin blocks were prepared by 21 undergraduate dental students with manual stainless steel files using a stepback technique or with rotary Ni-Ti files in crown-down technique. Preparation length, canal shape, incidence of fracture and preparation time were investigated. Zips and elbows occurred significantly (P < 0.001) less frequently with rotary than with manual preparation. The correct preparation length was achieved significantly (P < 0.05) more often with rotary Ni-Ti files than with manual stainless steel files. Fractures occurred significantly (P < 0.05) less frequently with hand instrumentation. The mean time required for manual preparation was significantly (P < 0.001) longer than that required for rotary preparation. Prior experience with a hand preparation technique was not reflected in an improved quality of the subsequent engine-driven preparation. Inexperienced operators achieved better canal preparations with rotary Ni-Ti instruments than with manual stainless steel files. However, rotary preparation was associated with significantly more fractures.
Vieira, E P; França, E C; Martins, R C; Buono, V T L; Bahia, M G A
2008-02-01
To examine the influence of clinical use on the occurrence of deformation and fracture and on the fatigue resistance of ProTaper rotary instruments. Root canal treatments were performed on patients using the ProTaper rotary system. Ten sets of instruments were used by an experienced endodontist, each set in five molars. Another 10 sets of instruments were used by the same operator, each set in eight molars. In addition, 10 sets of instruments were used, each set in five molars, by undergraduate students with no clinical experience with the system. After clinical use, S1, S2, F1 and F2 instruments were analysed for damage by optical and scanning electron microscopy. The used sets, along with a control group of 12 sets of new instruments, were then tested in a bench device for fatigue resistance. The use of the ProTaper rotary instruments by an experienced endodontist allowed for the cleaning and shaping of the root canal system of up to eight molars without fracture. During the students work, six instruments fractured. Fatigue resistance decreased upon clinical use for all instruments analysed. Fatigue resistance of used instruments was reduced, but no significant change was observed amongst the instruments used for shaping the canals of five and eight molars. Operator experience affected the occurrence of fracture and plastic deformation during shaping.
Singbal, Kiran; Jain, Disha; Raja, Kranthi; Hoe, Tan Ming
2017-01-01
Background: Apical extrusion of debris during instrumentation is detrimental to the patient. Aim: The aim of this study was to evaluate the apical extrusion of debris during root canal instrumentation using two single file rotary Ni-Ti systems. Materials and Methods: Thirty freshly extracted mandibular premolars with straight roots were sterilized and divided into two groups instrumented using: One Shape rotary Ni-Ti system with Endoflare orifice shaper (Group 1) and Neo-Niti rotary Ni-Ti system with C1 orifice shaper (Group 2). Preweighed Eppendorf tubes fitted for each tooth before instrumentation. During instrumentation, 1 mL of distilled water with a 30-gauge needle was used to irrigate after every instrument. Tips of the tooth were irrigated with 2 ml distilled water after removal from Eppendorf tubes. The total volume of irrigant in each group was the same 8 ml. All tubes were incubated at 68°C for 15 days and subsequently weighed. The difference between pre- and post-debris weights was calculated, and statistical analysis was performed using independent t-test and level of significance was set at 0.05. Results: The difference between pre- and post-weights was significantly greater for the One Shape system. Conclusions: The Neolix Niti single file was associated with less extrusion compared to One Shape single file system. PMID:28855748
Kustarci, Alper; Akdemir, Neslihan; Siso, Seyda Herguner; Altunbas, Demet
2008-01-01
Objectives The purpose of this study was to compare in-vitro the amount of debris extruded apically from extracted teeth, using K3, Protaper rotary instruments and manual step-back technique. Methods Forty five human single-rooted mandibular premolar teeth were randomly divided into 3 groups. The teeth in 3 groups were instrumented until reaching the working length with K3, Protaper rotary instruments and K-type stainless steel instruments with manual step-back technique, respectively. Debris extruded from the apical foramen was collected into centrifuge tubes and the amount was determined. The data obtained were analyzed using Kruskal-Wallis one-way analysis of variance and Mann-Whitney U tests, with P=.05 as the level for statistical significance. Results Statistically significant difference was observed between K3, Protaper and step-back groups in terms of debris extrusion (P<.05). Step-back group had the highest mean debris weight, which was significantly different from the K3 and Protaper groups (P<.05). The lowest mean debris weight was related to K3 group, which was significantly different from the Protaper group (P<.05). Conclusions: Based on the results, all instrumentation techniques produced debris extrusion. The engine-driven Ni-Ti systems extruded significantly less apical debris than step-back technique. However, Protaper rotary instruments extruded significantly more debris than K3 rotary instruments. PMID:19212528
Kustarci, Alper; Akdemir, Neslihan; Siso, Seyda Herguner; Altunbas, Demet
2008-10-01
The purpose of this study was to compare in-vitro the amount of debris extruded apically from extracted teeth, using K3, Protaper rotary instruments and manual step-back technique. Forty five human single-rooted mandibular premolar teeth were randomly divided into 3 groups. The teeth in 3 groups were instrumented until reaching the working length with K3, Protaper rotary instruments and K-type stainless steel instruments with manual step-back technique, respectively. Debris extruded from the apical foramen was collected into centrifuge tubes and the amount was determined. The data obtained were analyzed using Kruskal-Wallis one-way analysis of variance and Mann-Whitney U tests, with P=.05 as the level for statistical significance. Statistically significant difference was observed between K3, Protaper and step-back groups in terms of debris extrusion (P<.05). Step-back group had the highest mean debris weight, which was significantly different from the K3 and Protaper groups (P<.05). The lowest mean debris weight was related to K3 group, which was significantly different from the Protaper group (P<.05). Based on the results, all instrumentation techniques produced debris extrusion. The engine-driven Ni-Ti systems extruded significantly less apical debris than step-back technique. However, Protaper rotary instruments extruded significantly more debris than K3 rotary instruments.
Singbal, Kiran; Jain, Disha; Raja, Kranthi; Hoe, Tan Ming
2017-01-01
Apical extrusion of debris during instrumentation is detrimental to the patient. The aim of this study was to evaluate the apical extrusion of debris during root canal instrumentation using two single file rotary Ni-Ti systems. Thirty freshly extracted mandibular premolars with straight roots were sterilized and divided into two groups instrumented using: One Shape rotary Ni-Ti system with Endoflare orifice shaper (Group 1) and Neo-Niti rotary Ni-Ti system with C1 orifice shaper (Group 2). Preweighed Eppendorf tubes fitted for each tooth before instrumentation. During instrumentation, 1 mL of distilled water with a 30-gauge needle was used to irrigate after every instrument. Tips of the tooth were irrigated with 2 ml distilled water after removal from Eppendorf tubes. The total volume of irrigant in each group was the same 8 ml. All tubes were incubated at 68°C for 15 days and subsequently weighed. The difference between pre- and post-debris weights was calculated, and statistical analysis was performed using independent t -test and level of significance was set at 0.05. The difference between pre- and post-weights was significantly greater for the One Shape system. The Neolix Niti single file was associated with less extrusion compared to One Shape single file system.
Design study of a high power rotary transformer
NASA Technical Reports Server (NTRS)
Weinberger, S. M.
1982-01-01
A design study was made on a rotary transformer for transferring electrical power across a rotating spacecraft interface. The analysis was performed for a 100 KW, 20 KHz unit having a ""pancake'' geometry. The rotary transformer had a radial (vertical) gap and consisted of 4-25 KW modules. It was assumed that the power conditioning comprised of a Schwarz resonant circuit with a 20 KHz switching frequency. The rotary transformer, mechanical and structural design, heat rejection system and drive mechanism which provide a complete power transfer device were examined. The rotary transformer losses, efficiency, weight and size were compared with an axial (axial symmetric) gap transformer having the same performance requirements and input characteristics which was designed as part of a previous program. The ""pancake'' geometry results in a heavier rotary transformer primarily because of inefficient use of the core material. It is shown that the radial gap rotary transformer is a feasible approach for the transfer of electrical power across a rotating interface and can be implemented using presently available technology.
2015-09-01
Transfer Pump Liner before Testing with 25/75 ATJ/JP-8 Fuel with 9-ppm CI/LI...46 Figure 26. Pump SN:16756534 Transfer Pump Liner with 251-hours Testing with 25/75 ATJ/JP-8 Fuel...Transfer Pump Liner before Testing with 25/75 ATJ/JP-8 Fuel with 9-ppm CI/LI
Research on dynamic balancing simulation of rotary shaft based on ADAMS
NASA Astrophysics Data System (ADS)
Zheng, Weiqiang; Rui, Chengjie; Yang, Jie; Liu, Pingyi
2018-02-01
Due to the design and processing technology of rotary shaft, the mass center of it does not coincide with the rotating axis of the rotary shaft and there is an unbalanced mass. The unbalanced mass can have some disadvantages, such as the centrifugal force, the vibration and so on. Those disadvantages could reduce the accuracy and service life of the equipment.In this paper, the dynamic balance of the rotary shaft is analysed by the theory analysis combined with the dynamic simulation software. This method ensures that the rotary shaft meets the dynamic balancing requirements during the design stage. It effectively supports the structural design of the rotary shift, and provides a way of thinking and method for the design and development of the same type of products.
Design of a new separable rotary transformer
NASA Astrophysics Data System (ADS)
Gong, X. F.; Zhang, L.; Feng, E. J.
2017-09-01
A new-type separable rotary transformer which can be used in rotary steerable drilling is designed to deliver power efficiently from a stationary primary source to a rotary secondary load over a relatively large air gap via magnetic coupling. In this paper, E-type magnetic cores are reasonably distributed so that rotation of the rotary secondary has the least influence on reluctance of magnetic coupling. The influence of different winding layouts and connection modes on self-inductance and coupling coefficient is studied. By analysing the influence of the different geometrical shapes of cores on magnetic path, a design principle is proposed.
Free Flight Rotorcraft Flight Test Vehicle Technology Development
NASA Technical Reports Server (NTRS)
Hodges, W. Todd; Walker, Gregory W.
1994-01-01
A rotary wing, unmanned air vehicle (UAV) is being developed as a research tool at the NASA Langley Research Center by the U.S. Army and NASA. This development program is intended to provide the rotorcraft research community an intermediate step between rotorcraft wind tunnel testing and full scale manned flight testing. The technologies under development for this vehicle are: adaptive electronic flight control systems incorporating artificial intelligence (AI) techniques, small-light weight sophisticated sensors, advanced telepresence-telerobotics systems and rotary wing UAV operational procedures. This paper briefly describes the system's requirements and the techniques used to integrate the various technologies to meet these requirements. The paper also discusses the status of the development effort. In addition to the original aeromechanics research mission, the technology development effort has generated a great deal of interest in the UAV community for related spin-off applications, as briefly described at the end of the paper. In some cases the technologies under development in the free flight program are critical to the ability to perform some applications.
Overview of the NASA Subsonic Rotary Wing Aeronautics Research Program in Rotorcraft Crashworthiness
NASA Technical Reports Server (NTRS)
Jackson, Karen E.; Kellas, Sotiris; Fuchs, Yvonne T.
2009-01-01
This paper provides an overview of rotorcraft crashworthiness research being conducted at NASA Langley Research Center under sponsorship of the Subsonic Rotary Wing (SRW) Aeronautics Program. The research is focused in two areas: development of an externally deployable energy attenuating concept and improved prediction of rotorcraft crashworthiness. The deployable energy absorber (DEA) is a composite honeycomb structure, with a unique flexible hinge design that allows the honeycomb to be packaged and remain flat until needed for deployment. The capabilities of the DEA have been demonstrated through component crush tests and vertical drop tests of a retrofitted fuselage section onto different surfaces or terrain. The research on improved prediction of rotorcraft crashworthiness is focused in several areas including simulating occupant responses and injury risk assessment, predicting multi-terrain impact, and utilizing probabilistic analysis methods. A final task is to perform a system-integrated simulation of a full-scale helicopter crash test onto a rigid surface. A brief description of each research task is provided along with a summary of recent accomplishments.
Overview of the NASA Subsonic Rotary Wing Aeronautics Research Program in Rotorcraft Crashworthiness
NASA Technical Reports Server (NTRS)
Jackson, Karen E.; Fuchs, Yvonne T.; Kellas, Sotiris
2008-01-01
This paper provides an overview of rotorcraft crashworthiness research being conducted at NASA Langley Research Center under sponsorship of the Subsonic Rotary Wing (SRW) Aeronautics Program. The research is focused in two areas: development of an externally deployable energy attenuating concept and improved prediction of rotorcraft crashworthiness. The deployable energy absorber (DEA) is a composite honeycomb structure, with a unique flexible hinge design that allows the honeycomb to be packaged and remain flat until needed for deployment. The capabilities of the DEA have been demonstrated through component crush tests and vertical drop tests of a retrofitted fuselage section onto different surfaces or terrain. The research on improved prediction of rotorcraft crashworthiness is focused in several areas including simulating occupant responses and injury risk assessment, predicting multi-terrain impact, and utilizing probabilistic analysis methods. A final task is to perform a system-integrated simulation of a full-scale helicopter crash test onto a rigid surface. A brief description of each research task is provided along with a summary of recent accomplishments.
Analysis of particulate contaminations of infusion solutions in a pediatric intensive care unit.
Jack, Thomas; Brent, Bernadette E; Boehne, Martin; Müller, Meike; Sewald, Katherina; Braun, Armin; Wessel, Armin; Sasse, Michael
2010-04-01
To examine the physical properties and chemical composition of particles captured by in-line microfilters in critically ill children, and to investigate the inflammatory and cytotoxic effects of particles on endothelial cells (HUVEC) and macrophages in vitro. Prospective, observational study of microfilters following their use in the pediatric intensive care unit. In vitro model utilizing cytokine assays to investigate the effects of particles on human endothelial cells and murine macrophages. Twenty filter membranes from nine patients and five controls were examined by electron microscopy (EM) and energy dispersion spectroscopy (EDX). The average number of particles found on the surface of the used membranes was 550 cm(2). EDX analysis confirmed silicon as a major particle constituent. Half of the filter membranes showed conglomerates containing an unaccountable number of smaller particles. In vitro, glass particles were used to mimic the high silicon content particles. HUVEC and murine macrophages were exposed to different contents of particles, and cytokine levels were assayed to assess their immune response. Levels of interleukin-1beta, interleukin-6, interleukin-8, and tumor necrosis factor alpha were suppressed. Particle contamination of infusion solutions exists despite a stringent infusion regiment. The number and composition of particles depends on the complexity of the applied admixtures. Beyond possible physical effects, the suppression of macrophage and endothelial cell cytokine secretion in vitro suggests that microparticle infusion in vivo may have immune-modulating effects. Further clinical trials are necessary to determine whether particle retention by in-line filtration has an influence on the outcome of intensive care patients.
Performance Study of Ceramic Filter Module in Recirculated Aquaculture System (RAS)
NASA Astrophysics Data System (ADS)
Ng, L. Y.; Ng, C. Y.
2017-06-01
The growth of world population has led to significant increase in seafood demand over the world. Aquaculture has been widely accepted by many countries to increase the seafood production owing to the decline of natural seafood resources. The aquaculture productivity, however, is directly linked to the pond water quality. In this study, attempts were made to employ ceramic micro-filter to improve the pond water quality through filtration processes. There were two batches of filtration processes, short term (1 hour) and long term (48 hours). Significant improvements on real pond water quality were recorded through the short term microfiltration process, which reduced turbidity (96%), total suspended solids (TSS) (80%), biochemical oxygen demand (BOD) (72%), chemical oxygen demand (COD) (55%), ammonia (60%), nitrate (96%) and phosphorus (83%). The long term filtration process also showed high efficiency in the removal of solid particle and organic matters. The results showed that all of the parameters were successfully reduced to acceptable ranges (turbidity<80 NTU, TSS<400 mg/L, BOD<5 mg/L, COD<70 mg/L, phosphate<3 mg/L and ammonia<0.05 mg/L) for fish culturing activity. Based on current study, there was a drastic increase in nitrate content after 24 hours due to the nitrification process by regenerated bacteria in the filtered pond water. Current study showed that the microfiltration using ceramic micro-filter has high potential to be used in recirculating aquaculture system throughout the aquaculture activities in order to maintain the pond water quality, thus, increase the survival rate of cultured species.
Antunes, A E C; Silva E Alves, A T; Gallina, D A; Trento, F K H S; Zacarchenco, P B; Van Dender, A G F; Moreno, I; Ormenese, R C S C; Spadoti, L M
2014-09-01
The segment of the world population showing permanent or temporary lactose intolerance is quite significant. Because milk is a widely consumed food with an high nutritional value, technological alternatives have been sought to overcome this dilemma. Microfiltration combined with pasteurization can not only extend the shelf life of milk but can also maintain the sensory, functional, and nutritional properties of the product. This studied developed a pasteurized, microfiltered, lactose hydrolyzed (delactosed) skim milk (PMLHSM). Hydrolysis was performed using β-galactosidase at a concentration of 0.4mL/L and incubation for approximately 21h at 10±1°C. During these procedures, the degree of hydrolysis obtained (>90%) was accompanied by evaluation of freezing point depression, and the remaining quantity of lactose was confirmed by HPLC. Milk was processed using a microfiltration pilot unit equipped with uniform transmembrane pressure (UTP) ceramic membranes with a mean pore size of 1.4 μm and UTP of 60 kPa. The product was submitted to physicochemical, microbiological, and sensory evaluations, and its shelf life was estimated. Microfiltration reduced the aerobic mesophilic count by more than 4 log cycles. We were able to produce high-quality PMLHSM with a shelf life of 21 to 27d when stored at 5±1°C in terms of sensory analysis and proteolysis index and a shelf life of 50d in regard to total aerobic mesophile count and titratable acidity. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
High Bandwidth Rotary Fast Tool Servos and a Hybrid Rotary/Linear Electromagnetic Actuator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Montesanti, Richard Clement
2005-09-01
This thesis describes the development of two high bandwidth short-stroke rotary fast tool servos and the hybrid rotary/linear electromagnetic actuator developed for one of them. Design insights, trade-o® methodologies, and analytical tools are developed for precision mechanical systems, power and signal electronic systems, control systems, normal-stress electromagnetic actuators, and the dynamics of the combined systems.
Evaluation of scanning earth sensor mechanism on engineering test satellite 4
NASA Technical Reports Server (NTRS)
Ikeuchi, M.; Wakabayashi, Y.; Ohkami, Y.; Kida, T.; Ishigaki, T.; Matsumoto, M.
1983-01-01
The results of the analysis and the evaluation of flight data obtained from the horizon sensor test project are described. The rotary mechanism of the scanning earth sensor composed of direct drive motor and bearings using solid lubricant is operated satisfactorily. The transmitted flight data from Engineering Test Satellite IV was evaluated in comparison with the design value.
de Carvalho, Fredson Marcio Acris; Gonçalves, Leonardo Cantanhede de Oliveira; Marques, André Augusto Franco; Alves, Vanessa; Bueno, Carlos Eduardo da Silveira; De Martin, Alexandre Sigrist
2016-01-01
Objective: To compare cleaning effectiveness by histological analysis of a reciprocating single-file system with ProTaper rotary instruments during the preparation of curved root canals in extracted teeth. Methods: A total of 40 root canals with curvatures ranging between 20 - 40 degrees were divided into two groups of 20 canals. Canals were prepared to the following apical sizes: Reciproc size 25 (n=20); ProTaper: F2 (n=20). The normal distribution of data was tested by the Kolmogorov-Smirnov test and the values obtained for the test (Mann-Whitney U test, P < .05) were statistically analyzed using the GraphPad InStat for the Mac OS software (GraphPad Software, La Jolla, CA, USA). Results: There were no significant differences in remaining debris (P > .05) between the two groups. Conclusion: The application of reciprocating motion during instrumentation did not result in increased debris when compared with continuous rotation motion, even in the apical part of curved canals. Both instruments resulted in debris in the canal lumen, irrespective of the movement kinematics applied. PMID:28217185
The Vestibular Effects of Repeated Low-Level Blasts.
Littlefield, Philip D; Pinto, Robin L; Burrows, Holly L; Brungart, Douglas S
2016-01-01
The objective of this study was to use a prospective cohort of United States Marine Corps (USMC) instructors to identify any acute or long-term vestibular dysfunction following repeated blast exposures during explosive breaching training. They were assessed in clinic and on location during training at the USMC Methods of Entry School, Quantico, VA. Subjects received comprehensive baseline vestibular assessments and these were repeated in order to identify longitudinal changes. They also received shorter assessments immediately following blast exposure in order to identify acute findings. The main outcome measures were the Neurobehavioral Symptom Inventory, vestibular Visual Analog Scale (VAS) of subjective vestibular function, videonystagmography (VNG), vestibular evoked myogenic potentials (VEMP), rotary chair (including the unilateral centrifugation test), computerized dynamic posturography, and computerized dynamic visual acuity. A total of 11 breachers and 4 engineers were followed for up to 17 months. No acute effects or longitudinal deteriorations were identified, but there were some interesting baseline group differences. Upbeat positional nystagmus was common, and correlated (p<0.005) with a history of mild traumatic brain injury (mTBI). Several instructors had abnormally short low-frequency phase leads on rotary chair testing. This study evaluated breaching instructors over a longer test period than any other study, and the results suggest that this population appears to be safe from a vestibular standpoint at the current exposure levels. Upbeat positional nystagmus correlated with a history of mTBI in this population, and this has not been described elsewhere. The data trends also suggest that this nystagmus could be an acute blast effect. However, the reasons for the abnormally short phase leads seen in rotary chair testing are unclear at this time. Further investigation seems warranted.
Herman, David T [Aiken, SC; Maxwell, David N [Aiken, SC
2011-04-19
A rotary filtration apparatus for filtering a feed fluid into permeate is provided. The rotary filtration apparatus includes a container that has a feed fluid inlet. A shaft is at least partially disposed in the container and has a passageway for the transport of permeate. A disk stack made of a plurality of filtration disks is mounted onto the shaft so that rotation of the shaft causes rotation of the filtration disks. The filtration disks may be made of steel components and may be welded together. The shaft may penetrate a filtering section of the container at a single location. The rotary filtration apparatus may also incorporate a bellows seal to prevent leakage along the shaft, and an around the shaft union rotary joint to allow for removal of permeate. Various components of the rotary filtration apparatus may be removed as a single assembly.
NASA Astrophysics Data System (ADS)
Bondarenko, J. A.; Fedorenko, M. A.; Pogonin, A. A.
2018-03-01
Large parts can be treated without disassembling machines using “Extra”, having technological and design challenges, which differ from the challenges in the processing of these components on the stationary machine. Extension machines are used to restore large parts up to the condition allowing one to use them in a production environment. To achieve the desired accuracy and surface roughness parameters, the surface after rotary grinding becomes recoverable, which greatly increases complexity. In order to improve production efficiency and productivity of the process, the qualitative rotary processing of the machined surface is applied. The rotary cutting process includes a continuous change of the cutting edge surfaces. The kinematic parameters of a rotary cutting define its main features and patterns, the cutting operation of the rotary cutting instrument.
Developing a laboratory protocol for asphalt binder recovery.
DOT National Transportation Integrated Search
2014-10-01
Asphalt binder extraction and recovery are common laboratory procedures used to provide material for research and quality : assurance testing. The most common methods of recovery performed today include the Abson method and the rotary evaporator : (o...
Comparison of cyclic fatigue resistance of original and counterfeit rotary instruments.
Ertas, Huseyin; Capar, Ismail Davut; Arslan, Hakan; Akan, Ender
2014-05-31
In recent years, with the advances in counterfeiting methods, counterfeit products have reached the dental market. The purpose of this study was to compare the cyclic fatigue resistance of original and counterfeit rotary root canal instruments. The cyclic fatigue of original and counterfeit ProTaper F2 endodontic instruments was tested (n = 20) in 3 mm radius steel canals with a 60° angle of curvature. The number of cycles to fracture (NCF) was calculated, and the data were subjected to the Student's t-test (α = 0.05). The original instruments showed better cyclic fatigue resistance than the counterfeit ones (p < .001). The mean NCF was 483 ± 84 for the original files and 186 ± 86 for the counterfeit files. The cyclic fatigue resistance of the counterfeit instruments was very low. As a result, clinicians should be careful not to purchase counterfeit products.
Middeck zero-gravity dynamics experiment - Comparison of ground and flight test data
NASA Technical Reports Server (NTRS)
Crawley, Edward F.; Barlow, Mark S.; Van Schoor, Marthinus C.; Masters, Brett; Bicos, Andrew S.
1992-01-01
An analytic and experimental study of the changes in the modal parameters of space structural test articles from one- to zero-gravity is presented. Deployable, erectable, and rotary modules was assembled to form three one- and two-dimensional structures, in which variations in bracing wire and rotary joint preload could be introduced. The structures were modeled as if hanging from a suspension system in one gravity, and unconstrained, as if free floating in zero-gravity. The analysis is compared with ground experimental measurements, made on a spring/wire suspension system with a nominal plunge frequency of one Hertz, and with measurements made on the Shuttle middeck. The degree of change in linear modal parameters as well as the change in nonlinear nature of the response is examined. Trends in modal parameters are presented as a function of force amplitude, joint preload, and ambient gravity level.
New immiscible refrigeration lubricant for HFCs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sunami, Motoshi; Takigawa, Katsuya; Suda, Satoshi
1995-12-31
This study examines the capability of a family of very low-viscosity alkylbenzenes (AB) used in high-side rotary compressors for HFCs. In the development of refrigeration lubricants for HFCs, miscibility is one of the most important problems to be solved. Therefore, PAG (polyalkylene glycols) and POE (polyol esters), which have good miscibility, have been applied in new HFC applications. However, it is difficult for these lubricants to maintain long-term durability in high-side rotary compressors. In friction tests under high HFC pressure, ABs with much lower viscosities than mineral oil maintained a much stronger oil film than the combination of mineral oil/R-12more » or POE/HFCs. These results were also proven by compressor durability tests. From the study of the solubility of ABs and HFCs, it is suggested that the total amount of refrigerant can be reduced because HFCs are barely soluble with ABs inside the high-side shell.« less
Sequenced drive for rotary valves
Mittell, Larry C.
1981-01-01
A sequenced drive for rotary valves which provides the benefits of applying rotary and linear motions to the movable sealing element of the valve. The sequenced drive provides a close approximation of linear motion while engaging or disengaging the movable element with the seat minimizing wear and damage due to scrubbing action. The rotary motion of the drive swings the movable element out of the flowpath thus eliminating obstruction to flow through the valve.
Hou, Xiao-Mei; Su, Zheng; Hou, Ben-Xiang
2017-05-25
In endodontic therapy, continuous rotary instrumentation reduced debris compared to reciprocal instrumentation, which might affect the incidence of post-endodontic pain (PP). The aim of our study was to assess whether PP incidence and levels were influenced by the choice of rotary or reciprocal instruments. In this meta-analysis the Pubmed and EM databases were searched for prospective clinical randomized trials published before April 20, 2016, using combinations of the keywords: root canal preparation/instrumentation/treatment/therapy; post-operative/endodontic pain; reciprocal and rotary instruments. Three studies were included, involving a total of 1,317 patients, 659 treated with reciprocating instruments and 658 treated with rotary instruments. PP was reported in 139 patients in the reciprocating group and 172 in the rotary group. The PP incidence odds ratio was 1.27 with 95% confidence interval (CI) (0.25, 6.52) favoring rotary instruments. The mild, moderate and severe PP levels odds ratios were 0.31 (0.11, 0.84), 2.24 (0.66, 7.59) and 11.71 (0.63, 218.15), respectively. No evidence of publication bias was found. Rotary instrument choice in endodontic therapy is associated with a lower incidence of PP than reciprocating instruments, while reciprocating instruments are associated with less mild PP incidence.
Rotary piston blood pumps: past developments and future potential of a unique pump type.
Wappenschmidt, Johannes; Autschbach, Rüdiger; Steinseifer, Ulrich; Schmitz-Rode, Thomas; Margreiter, Raimund; Klima, Günter; Goetzenich, Andreas
2016-08-01
The design of implantable blood pumps is either based on displacement pumps with membranes or rotary pumps. Both pump types have limitations to meet the clinical requirements. Rotary piston blood pumps have the potential to overcome these limitations and to merge the benefits. Compared to membrane pumps, they are smaller and with no need for wear-affected membranes and valves. Compared to rotary pumps, the blood flow is pulsatile instead of a non-physiological continuous flow. Furthermore, the risk of flow-induced blood damage and platelet activation may be reduced due to low shear stress to the blood. The past developments of rotary piston blood pumps are summarized and the main problem for long-term application is identified: insufficient seals. A new approach with seal-less drives is proposed and current research on a simplified rotary piston design is presented. Expert commentary: The development of blood pumps focuses mainly on the improvement of rotary pumps. However, medical complications indicate that inherent limitations of this pump type remain and restrict the next substantial step forward in the therapy of heart failure patients. Thus, research on different pump types is reasonable. If the development of reliable drives and bearings succeeds, rotary piston blood pumps become a promising alternative.
25. INTERIOR OF ROTARY CAR DUMPER BUILDING WITH VIEW OF ...
25. INTERIOR OF ROTARY CAR DUMPER BUILDING WITH VIEW OF ROTARY CAR DUMPER LOOKING NORTHEAST. (Jet Lowe) - U.S. Steel Duquesne Works, Blast Furnace Plant, Along Monongahela River, Duquesne, Allegheny County, PA
Percussive Augmenter of Rotary Drills (PARoD)
NASA Technical Reports Server (NTRS)
Badescu, Mircea; Bar-Cohen, Yoseph; Sherrit, Stewart; Bao, Xiaoqi; Chang, Zensheu; Donnelly, Chris; Aldrich, Jack
2012-01-01
Increasingly, NASA exploration mission objectives include sample acquisition tasks for in-situ analysis or for potential sample return to Earth. To address the requirements for samplers that could be operated at the conditions of the various bodies in the solar system, a piezoelectric actuated percussive sampling device was developed that requires low preload (as low as 10N) which is important for operation at low gravity. This device can be made as light as 400g, can be operated using low average power, and can drill rocks as hard as basalt. Significant improvement of the penetration rate was achieved by augmenting the hammering action by rotation and use of a fluted bit to provide effective cuttings removal. Generally, hammering is effective in fracturing drilled media while rotation of fluted bits is effective in cuttings removal. To benefit from these two actions, a novel configuration of a percussive mechanism was developed to produce an augmenter of rotary drills. The device was called Percussive Augmenter of Rotary Drills (PARoD). A breadboard PARoD was developed with a 6.4 mm (0.25 in) diameter bit and was demonstrated to increase the drilling rate of rotation alone by 1.5 to over 10 times. Further, a large PARoD breadboard with 50.8 mm diameter bit was developed and its tests are currently underway. This paper presents the design, analysis and preliminary test results of the percussive augmenter.
Rodrigues, Renata C V; Lopes, Hélio P; Elias, Carlos N; Amaral, Georgiana; Vieira, Victor T L; De Martin, Alexandre S
2011-11-01
The aim of this study was to evaluate, by static and dynamic cyclic fatigue tests, the number of cycles to fracture (NCF) 2 types of rotary NiTi instruments: Twisted File (SybronEndo, Orange, CA), which is manufactured by a proprietary twisting process, and RaCe files (FKG Dentaire, La Chaux-de-Fonds, Switzerland), which are manufactured by grinding. Twenty Twisted Files (TFs) and 20 RaCe files #25/.006 taper instruments were allowed to rotate freely in an artificial curved canal at 310 rpm in a static or a dynamic model until fracture occurred. Measurements of the fractured fragments showed that fracture occurred at the point of maximum flexure in the midpoint of the curved segment. The NCF was significantly lower for RaCe instruments compared with TFs. The NCF was also lower for instruments subjected to the static test compared with the dynamic model in both groups. Scanning electron microscopic analysis revealed ductile morphologic characteristics on the fractured surfaces of all instruments and no plastic deformation in their helical shafts. Rotary NiTi endodontic instruments manufactured by twisting present greater resistance to cyclic fatigue compared with instruments manufactured by grinding. The fracture mode observed in all instruments was of the ductile type. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Fracture resistance of retreated roots using different retreatment systems.
Er, Kursat; Tasdemir, Tamer; Siso, Seyda Herguner; Celik, Davut; Cora, Sabri
2011-08-01
This study was designed to evaluate the fracture resistance of retreated roots using different rotary retreatment systems. Forty eight freshly extracted human canine teeth with single straight root canals were instrumented sequentially increasing from size 30 to a size 55 using K-files whit a stepback technique. The teeth were randomly divided into three experimental and one control groups of 12 specimens each. The root canals were filled using cold lateral compaction of gutta-percha and AH Plus (Dentsply Detrey, Konstanz, Germany) sealer in experimental groups. Removal of gutta-percha was performed with the following devices and techniques: ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), R-Endo (Micro-Mega, Besançon, France), and Mtwo (Sweden & Martina, Padova, Italy) rotary retreatment systems. Control group specimens were only instrumented, not filled or retreated. The specimens were then mounted in copper rings, were filled with a self-curing polymethylmethacrylate resin, and the force required to cause vertical root fracture was measured using a universal testing device. The force of fracture of the roots was recorded and the results in the various groups were compared. Statistical analysis was accomplished by one-way ANOVA and a post hoc Tukey tests. There were statistically significant differences between the control and experimental groups (P<.05). However, there were no significant differences among the experimental groups. Based on the results, all rotary retreatment techniques used in this in vitro study produced similar root weakness.
NASA Astrophysics Data System (ADS)
Ihsani, V.; Nursasongko, B.; Djauharie, N.
2017-08-01
The concept of conserving healthy tooth structures during cavity preparation has gained popularity with chemo-mechanical caries removal. This study compared three methods of caries removal using: a chemo-mechanical caries removal papain gel; Papacarie® (these contain natural ingredients, mainly papain enzyme); and mechanical preparation with a bur rotary instrument. The purpose of this study was to compare affected dentin micro-hardness after removal of infected dentin with mechanical and chemo-mechanical techniques. Twenty-seven permanent molar teeth were randomly divided into three groups receiving removal of infected dentin. These were: Group 1: chemo-mechanical technique using papain gel; Group 2: chemo-mechanical technique using Papacarie® Group 3: mechanical technique using a bur rotary instrument. Each group was tested using Knoop Micro-hardness tester, and the data were submitted to one way ANOVA and Post-hoc Tukey test. There is a significant difference between Groups 1 and 3, and Groups 2 and 3, p = 0.000. However, there is no significant difference between Groups 1 and 2, p = 1.000. Affected dentin micro-hardness after removal of infected dentin with a bur rotary tool is higher than after use of the papain gel or Papacarie®. Affected dentin micro-hardness after removal of infected dentin with Papacarie® and papain gel give almost the same result.
Development of the RANCOR Rotary-Percussive Coring System for Mars Sample Return
NASA Technical Reports Server (NTRS)
Paulsen, Gale; Indyk, Stephen; Zacny, Kris
2014-01-01
A RANCOR drill was designed to fit a Mars Exploration Rover (MER) class vehicle. The low mass of 3 kg was achieved by using the same actuator for three functions: rotation, percussions, and core break-off. Initial testing of the drill exposed an unexpected behavior of an off-the-shelf sprag clutch used to couple and decouple rotary-percussive function from the core break off function. Failure of the sprag was due to the vibration induced during percussive drilling. The sprag clutch would back drive in conditions where it was expected to hold position. Although this did not affect the performance of the drill, it nevertheless reduced the quality of the cores produced. Ultimately, the sprag clutch was replaced with a custom ratchet system that allowed for some angular displacement without advancing in either direction. Replacing the sprag with the ratchet improved the collected core quality. Also, premature failure of a 300-series stainless steel percussion spring was observed. The 300-series percussion spring was ultimately replaced with a music wire spring based on performances of previously designed rotary-percussive drill systems.
Evaluation of cyclic flexural fatigue of M-wire nickel-titanium rotary instruments.
Al-Hadlaq, Solaiman M S; Aljarbou, Fahad A; AlThumairy, Riyadh I
2010-02-01
This study was conducted to investigate cyclic flexural fatigue resistance of GT series X rotary files made from the newly developed M-wire nickel-titanium alloy compared with GT and Profile nickel-titanium files made from a conventional nickel-titanium alloy. Fifteen files, size 30/0.04, of each type were used to evaluate the cyclic flexural fatigue resistance. A simple device was specifically constructed to measure the time each file type required to fail under cyclic flexural fatigue testing. The results of this experiment indicated that the GT series X files had superior cyclic flexural fatigue resistance than the other 2 file types made from a conventional nickel-titanium alloy (P = .004). On the other hand, the difference between the Profile and the GT files was not statistically significant. The findings of this study suggest that size 30/0.04 nickel-titanium rotary files made from the newly developed M-wire alloy have better cyclic flexural fatigue resistance than files of similar design and size made from the conventional nickel-titanium alloy. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Hultberg, R. S.; Mulcay, W.
1980-01-01
Aerodynamic characteristics obtained in a rotational flow environment utilizing a rotary balance are presented in plotted form for a 1/5 scale, single engine, low-wing, general aviation airplane model. The configuration tested included the basic airplane, various control deflections, tail designs, fuselage shapes, and wing leading edges. Data are presented without analysis for an angle of attack range of 8 to 90 deg and clockwise and counterclockwise rotations covering a range from 0 to 0.85.
NASA Technical Reports Server (NTRS)
Bihrle, W., Jr.; Hultberg, R. S.
1979-01-01
Aerodynamic characteristics obtained in a rotational flow environment utilizing a rotary balance located in the spin tunnel are presented in plotted form for a 1/6.5 scale, single engine, low wing, general aviation airplane model. The configurations tested included the basic airplane, various wing leading-edge devices, tail designs, and rudder control settings as well as airplane components. Data are presented without analysis for an angle-of-attack range of 8 deg to 90 deg and clockwise and counter-clockwise rotations covering an (omega)(b)/2V range from 0 to 0.85.
NASA Technical Reports Server (NTRS)
Bihrle, W., Jr.; Hultberg, R. S.; Mulcay, W.
1978-01-01
Aerodynamic characteristics obtained in a spinning flow environment utilizing a rotary balance located spin tunnel are presented in plotted form for a 1/5 scale single-engine low-wing general aviation airplane model. The configurations tested include the basic airplane, various airfoil shapes, tail designs, fuselage strakes and modifications as well as airplane components. Data are presented for pitch and roll angle ranges of 30 to 90 degrees and 10 to -10 degrees, respectively, and clockwise and counter-clockwise rotations covering an Omega b/2V range from 0 to .9. The data are presented without analysis.
NASA Technical Reports Server (NTRS)
Bihrle, W., Jr.; Hultberg, R. S.
1979-01-01
Aerodynamic characteristics obtained in a rotational flow environment utilizing a rotary balance located in a spin tunnel are presented in plotted form for a 1/6.5 scale, single engine, high wing, general aviation airplane model. The configurations tested included the basic airplane, various wing leading-edge devices, tail designs, and rudder control settings as well as airplane components. Data are presented without analysis for an angle of attack range of 8 deg to 90 deg and clockwise and counter-clockwise rotations covering an omega b/2V range from 0 to 0.85.
Funkenbusch, Paul D; Rotella, Mario; Chochlidakis, Konstantinos; Ercoli, Carlo
2016-10-01
Laboratory studies of tooth preparation often involve single values for all variables other than the one being tested. In contrast, in clinical settings, not all variables can be adequately controlled. For example, a new dental rotary cutting instrument may be tested in the laboratory by making a specific cut with a fixed force, but, in clinical practice, the instrument must make different cuts with individual dentists applying different forces. Therefore, the broad applicability of laboratory results to diverse clinical conditions is uncertain and the comparison of effects across studies difficult. The purpose of this in vitro study was to examine the effects of 9 process variables on the dental cutting of rotary cutting instruments used with an electric handpiece and compare them with those of a previous study that used an air-turbine handpiece. The effects of 9 key process variables on the efficiency of a simulated dental cutting operation were measured. A fractional factorial experiment was conducted by using an electric handpiece in a computer-controlled, dedicated testing apparatus to simulate dental cutting procedures with Macor blocks as the cutting substrate. Analysis of variance (ANOVA) was used to assess the statistical significance (α=.05). Four variables (targeted applied load, cut length, diamond grit size, and cut type) consistently produced large, statistically significant effects, whereas 5 variables (rotation per minute, number of cooling ports, rotary cutting instrument diameter, disposability, and water flow rate) produced relatively small, statistically insignificant effects. These results are generally similar to those previously found for an air-turbine handpiece. Regardless of whether an electric or air-turbine handpiece was used, the control exerted by the dentist, simulated in this study by targeting a specific level of applied force, was the single most important factor affecting cutting efficiency. Cutting efficiency was also significantly affected by factors simulating patient/clinical circumstances and hardware choices. These results highlight the greater importance of local clinical conditions (procedure, dentist) in understanding dental cutting as opposed to other hardware-related factors. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Nayak, Gurudutt; Singh, Inderpreet; Shetty, Shashit; Dahiya, Surya
2014-05-01
Apical extrusion of debris and irrigants during cleaning and shaping of the root canal is one of the main causes of periapical inflammation and postoperative flare-ups. The purpose of this study was to quantitatively measure the amount of debris and irrigants extruded apically in single rooted canals using two reciprocating and one rotary single file nickel-titanium instrumentation systems. Sixty human mandibular premolars, randomly assigned to three groups (n = 20) were instrumented using two reciprocating (Reciproc and Wave One) and one rotary (One Shape) single-file nickel-titanium systems. Bidistilled water was used as irrigant with traditional needle irrigation delivery system. Eppendorf tubes were used as test apparatus for collection of debris and irrigant. The volume of extruded irrigant was collected and quantified via 0.1-mL increment measure supplied on the disposable plastic insulin syringe. The liquid inside the tubes was dried and the mean weight of debris was assessed using an electronic microbalance. The data were statistically analysed using Kruskal-Wallis nonparametric test and Mann Whitney U test with Bonferroni adjustment. P-values less than 0.05 were considered significant. The Reciproc file system produced significantly more debris compared with OneShape file system (P<0.05), but no statistically significant difference was obtained between the two reciprocating instruments (P>0.05). Extrusion of irrigant was statistically insignificant irrespective of the instrument or instrumentation technique used (P >0.05). Although all systems caused apical extrusion of debris and irrigant, continuous rotary instrumentation was associated with less extrusion as compared with the use of reciprocating file systems.
Rotary Power Transformer and Inverter Circuit
NASA Technical Reports Server (NTRS)
Mclyman, C. W. T.; Bridgeforth, A. O.
1985-01-01
Noise lower than with sliprings. Rotary transformer transfers electric power across rotary joint. No wearing contacts, no contact noise, and no contamination from lubricants or wear debris. Because additional inductor not required, size and complexity of circuit reduced considerably.
DEMES rotary joint: theories and applications
NASA Astrophysics Data System (ADS)
Wang, Shu; Hao, Zhaogang; Li, Mingyu; Huang, Bo; Sun, Lining; Zhao, Jianwen
2017-04-01
As a kind of dielectric elastomer actuators, dielectric elastomer minimum energy structure (DEMES) can realize large angular deformations by small voltage-induced strains, which make them an attractive candidate for use as biomimetic robotics. Considering the rotary joint is a basic and common component of many biomimetic robots, we have been fabricated rotary joint by DEMES and developed its performances in the past two years. In this paper, we have discussed the static analysis, dynamics analysis and some characteristics of the DEMES rotary joint. Based on theoretical analysis, some different applications of the DEMES rotary joint were presented, such as a flapping wing, a biomimetic fish and a two-legged walker. All of the robots are fabricated by DEMES rotary joint and can realize some basic biomimetic motions. Comparing with traditional rigid robot, the robot based on DEMES is soft and light, so it has advantage on the collision-resistant.
NASA Technical Reports Server (NTRS)
Clark, B.; Stewart, J. D.
1974-01-01
This experiment was concerned with the effects of rotary acceleration on choice reaction time (RTc) to the motion of a luminous line on a cathode-ray tube. Specifically, it compared the (RTc) to rotary acceleration alone, visual acceleration alone, and simultaneous, double stimulation by both rotary and visual acceleration. Thirteen airline pilots were rotated about an earth-vertical axis in a precision rotation device while they observed a vertical line. The stimuli were 7 rotary and visual accelerations which were matched for rise time. The pilot responded as quickly as possible by displacing a vertical controller to the right or left. The results showed a decreasing (RTc) with increasing acceleration for all conditions, while the (RTc) to rotary motion alone was substantially longer than for all other conditions. The (RTc) to the double stimulation was significantly longer than that for visual acceleration alone.
Choice reaction time to visual motion during prolonged rotary motion in airline pilots
NASA Technical Reports Server (NTRS)
Stewart, J. D.; Clark, B.
1975-01-01
Thirteen airline pilots were studied to determine the effect of preceding rotary accelerations on the choice reaction time to the horizontal acceleration of a vertical line on a cathode-ray tube. On each trial, one of three levels of rotary and visual acceleration was presented with the rotary stimulus preceding the visual by one of seven periods. The two accelerations were always equal and were presented in the same or opposite directions. The reaction time was found to increase with increases in the time the rotary acceleration preceded the visual acceleration, and to decrease with increased levels of visual and rotary acceleration. The reaction time was found to be shorter when the accelerations were in the same direction than when they were in opposite directions. These results suggest that these findings are a special case of a general effect that the authors have termed 'gyrovisual modulation'.
NASA Astrophysics Data System (ADS)
Parsa, M. H.; Davari, H.; Hadian, A. M.; Ahmadabadi, M. Nili
2007-05-01
Hybrid Rotary Friction Welding is a modified type of common rotary friction welding processes. In this welding method parameters such as pressure, angular velocity and time of welding control temperature, stress, strain and their variations. These dependent factors play an important rule in defining optimum process parameters combinations in order to improve the design and manufacturing of welding machines and quality of welded parts. Thermo-mechanical simulation of friction welding has been carried out and it has been shown that, simulation is an important tool for prediction of generated heat and strain at the weld interface and can be used for prediction of microstructure and evaluation of quality of welds. For simulation of Hybrid Rotary Friction Welding, a commercial finite element program has been used and the effects of pressure and rotary velocity of rotary part on temperature and strain variations have been investigated.
Comparison of structural performance of one- and two-bay rotary joints for truss applications
NASA Technical Reports Server (NTRS)
Vail, J. Douglas; Lake, Mark S.
1991-01-01
The structural performance of one- and two-bay large-diameter discrete-bearing rotary joints was addressed for application to truss-beam structures such as the Space Station Freedom. Finite element analyses are performed to determine values for rotary joint parameters that give the same bending vibration frequency as the parent truss beam. The structural masses and maximum internal loads of these joints are compared to determine their relative structural efficiency. Results indicate that no significant difference exists in the masse of one- and two-bay rotary joints. This conclusion is reinforced with closed-form calculations of rotary joint structural efficiency in extension. Also, transition truss-member loads are higher in the one-bay rotary joint. However, because of the increased buckling strength of these members, the external load-carrying capability of the one-bay concept is higher than that of the two-bay concept.
More About Cutting Tool For Shaving Weld Beads
NASA Technical Reports Server (NTRS)
Oelgoetz, Peter A.; Davis, William M.
1996-01-01
Report describes modification and testing of proposed tool discussed in "Cutting Tool For Shaving Weld Beads" (MFS-30056). Modified version of commercial pneumatically driven rotary cutting tool removes such hard metals as nickel alloys, titanium, and stainless steels.
Lei, Xiao-hua; Ning, Li-na; Cao, Yu-jing; Liu, Shuang; Zhang, Shou-bing; Qiu, Zhi-fang; Hu, Hui-min; Zhang, Hui-shan; Liu, Shu; Duan, En-kui
2011-01-01
The skin is susceptible to different injuries and diseases. One major obstacle in skin tissue engineering is how to develop functional three-dimensional (3D) substitute for damaged skin. Previous studies have proved a 3D dynamic simulated microgravity (SMG) culture system as a "stimulatory" environment for the proliferation and differentiation of stem cells. Here, we employed the NASA-approved rotary bioreactor to investigate the proliferation and differentiation of human epidermal stem cells (hEpSCs). hEpSCs were isolated from children foreskins and enriched by collecting epidermal stem cell colonies. Cytodex-3 micro-carriers and hEpSCs were co-cultured in the rotary bioreactor and 6-well dish for 15 days. The result showed that hEpSCs cultured in rotary bioreactor exhibited enhanced proliferation and viability surpassing those cultured in static conditions. Additionally, immunostaining analysis confirmed higher percentage of ki67 positive cells in rotary bioreactor compared with the static culture. In contrast, comparing with static culture, cells in the rotary bioreactor displayed a low expression of involucrin at day 10. Histological analysis revealed that cells cultured in rotary bioreactor aggregated on the micro-carriers and formed multilayer 3D epidermis structures. In conclusion, our research suggests that NASA-approved rotary bioreactor can support the proliferation of hEpSCs and provide a strategy to form multilayer epidermis structure.
Rotation of artificial rotor axles in rotary molecular motors
Baba, Mihori; Iwamoto, Kousuke; Ueno, Hiroshi; Hara, Mayu; Nakanishi, Atsuko; Kishikawa, Jun-ichi; Noji, Hiroyuki; Yokoyama, Ken
2016-01-01
F1- and V1-ATPase are rotary molecular motors that convert chemical energy released upon ATP hydrolysis into torque to rotate a central rotor axle against the surrounding catalytic stator cylinder with high efficiency. How conformational change occurring in the stator is coupled to the rotary motion of the axle is the key unknown in the mechanism of rotary motors. Here, we generated chimeric motor proteins by inserting an exogenous rod protein, FliJ, into the stator ring of F1 or of V1 and tested the rotation properties of these chimeric motors. Both motors showed unidirectional and continuous rotation, despite no obvious homology in amino acid sequence between FliJ and the intrinsic rotor subunit of F1 or V1. These results showed that any residue-specific interactions between the stator and rotor are not a prerequisite for unidirectional rotation of both F1 and V1. The torque of chimeric motors estimated from viscous friction of the rotation probe against medium revealed that whereas the F1-FliJ chimera generates only 10% of WT F1, the V1-FliJ chimera generates torque comparable to that of V1 with the native axle protein that is structurally more similar to FliJ than the native rotor of F1. This suggests that the gross structural mismatch hinders smooth rotation of FliJ accompanied with the stator ring of F1. PMID:27647891
Movement kinematics and cyclic fatigue of NiTi rotary instruments: a systematic review.
Ferreira, F; Adeodato, C; Barbosa, I; Aboud, L; Scelza, P; Zaccaro Scelza, M
2017-02-01
The aim of this review was to provide a detailed analysis of the literature concerning the correlation between different movement kinematics and the cyclic fatigue resistance of NiTi rotary endodontic instruments. From June 2014 to August 2015, four independent reviewers comprehensively and systematically searched the Medline (PubMed), EMBASE, Web of Science, Scopus and Google Scholar databases for works published since January 2005, using the following search terms: endodontics; nickel-titanium rotary files; continuous rotation; reciprocating motion; cyclic fatigue. In addition to the electronic searches, manual searches were performed to include articles listed in the reference sections of high-impact published articles that were not indexed in the databases. Laboratory studies in English language were considered for this review. The electronic and manual searches resulted in identification of 75 articles. Based on the inclusion criteria, 32 articles were selected for analysis of full-text copies. Specific analysis was then made of 20 articles that described the effects of reciprocating and continuous movements on cyclic fatigue of the instruments. A wide range of testing conditions and methodologies have been used to compare the cyclic fatigue resistance of rotary endodontic instruments. Most studies report that reciprocating motion improves the fatigue resistance of endodontic instruments, compared to continuous rotation, independent of other variables such as the speed of rotation, the angle or radius of curvature of simulated canals, geometry and taper, or the surface characteristics of the NiTi instruments. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Ghogre, Priyanka; Chourasia, Hemant Ramesh; Agarwal, Manish; Singh, M P; Gurav, Sandeep; Ghogre, Rahul
2015-01-01
The aim of this study was to evaluate the number of intracanal bacteria extruded apically during root canal preparation using rotary ProTaper, K3XF, twisted, and hand K-file system. Seventy extracted single-rooted human mandibular premolar teeth were used. Access cavities were prepared and the teeth were mounted in glass vials. Root canals were then contaminated with a pure culture of Enterococcus faecalis (ATCC 29212) and incubated at 37°C for 24 h. The contaminated roots were divided into four experimental groups of 15 teeth each and one control group of 10 teeth. Group 1: ProTaper; Group 2: K3XF; Group 3: Twisted file; Group 4: Hand K-file; Group 5: Control group. Bacteria extruded from the apical foramen during instrumentation were collected into vials. The microbiological samples were incubated in culture media for 24 h. Colonies of bacteria were counted and the results were given as number of colony-forming units (CFU)/ml. The obtained data were analyzed using the Kruskal-Wallis one-way analysis of variance and Mann-Whitney U-tests. There was a significant difference between the rotary and hand instrumentation system related to the apically extruded intracanal bacteria. Both the rotary and hand instrumentation systems extruded intracanal bacteria through the apical foramen. K3XF file system showed least bacterial extrusion amongst all instrumentation groups.
Apically extruded dentin debris by reciprocating single-file and multi-file rotary system.
De-Deus, Gustavo; Neves, Aline; Silva, Emmanuel João; Mendonça, Thais Accorsi; Lourenço, Caroline; Calixto, Camila; Lima, Edson Jorge Moreira
2015-03-01
This study aims to evaluate the apical extrusion of debris by the two reciprocating single-file systems: WaveOne and Reciproc. Conventional multi-file rotary system was used as a reference for comparison. The hypotheses tested were (i) the reciprocating single-file systems extrude more than conventional multi-file rotary system and (ii) the reciprocating single-file systems extrude similar amounts of dentin debris. After solid selection criteria, 80 mesial roots of lower molars were included in the present study. The use of four different instrumentation techniques resulted in four groups (n = 20): G1 (hand-file technique), G2 (ProTaper), G3 (WaveOne), and G4 (Reciproc). The apparatus used to evaluate the collection of apically extruded debris was typical double-chamber collector. Statistical analysis was performed for multiple comparisons. No significant difference was found in the amount of the debris extruded between the two reciprocating systems. In contrast, conventional multi-file rotary system group extruded significantly more debris than both reciprocating groups. Hand instrumentation group extruded significantly more debris than all other groups. The present results yielded favorable input for both reciprocation single-file systems, inasmuch as they showed an improved control of apically extruded debris. Apical extrusion of debris has been studied extensively because of its clinical relevance, particularly since it may cause flare-ups, originated by the introduction of bacteria, pulpal tissue, and irrigating solutions into the periapical tissues.
Paqué, Frank; Rechenberg, Dan-Krister; Zehnder, Matthias
2012-05-01
Hard-tissue debris is accumulated during rotary instrumentation. This study investigated to what extent a calcium-complexing agent that has good short-term compatibility with sodium hypochlorite (NaOCl) could reduce debris accumulation when applied in an all-in-one irrigant during root canal instrumentation. Sixty extracted mandibular molars with isthmuses in the mesial root canal system were selected based on prescans using a micro-computed tomography system. Thirty teeth each were randomly assigned to be instrumented with a rotary system and irrigated with either 2.5% NaOCl or 2.5% NaOCl containing 9% (wt/vol) etidronic acid (HEBP). Using a side-vented irrigating tip, 2 mL of irrigant was applied by 1 blinded investigator to the mesial canals after each instrument. Five milliliters of irrigant was applied per canal as the final rinse. Mesial root canal systems were scanned at high resolution before and after treatment, and accumulated hard-tissue debris was calculated as vol% of the original canal anatomy. Values between groups were compared using the Student's t test (α < .05). Irrigation with 2.5% NaOCl resulted in 5.5 ± 3.6 vol% accumulated hard-tissue debris compared with 3.8 ± 1.8 vol% when HEBP was contained in the irrigant (P < .05). A hypochlorite-compatible chelator can reduce but not completely prevent hard-tissue debris accumulation during rotary root canal instrumentation. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
21 CFR 872.4840 - Rotary scaler.
Code of Federal Regulations, 2014 CFR
2014-04-01
... DENTAL DEVICES Surgical Devices § 872.4840 Rotary scaler. (a) Identification. A rotary scaler is an abrasive device intended to be attached to a powered handpiece to remove calculus deposits from teeth during dental cleaning and periodontal (gum) therapy. (b) Classification. Class II. ...
21 CFR 872.4840 - Rotary scaler.
Code of Federal Regulations, 2012 CFR
2012-04-01
... DENTAL DEVICES Surgical Devices § 872.4840 Rotary scaler. (a) Identification. A rotary scaler is an abrasive device intended to be attached to a powered handpiece to remove calculus deposits from teeth during dental cleaning and periodontal (gum) therapy. (b) Classification. Class II. ...
21 CFR 872.4840 - Rotary scaler.
Code of Federal Regulations, 2011 CFR
2011-04-01
... DENTAL DEVICES Surgical Devices § 872.4840 Rotary scaler. (a) Identification. A rotary scaler is an abrasive device intended to be attached to a powered handpiece to remove calculus deposits from teeth during dental cleaning and periodontal (gum) therapy. (b) Classification. Class II. ...
21 CFR 872.4840 - Rotary scaler.
Code of Federal Regulations, 2013 CFR
2013-04-01
... DENTAL DEVICES Surgical Devices § 872.4840 Rotary scaler. (a) Identification. A rotary scaler is an abrasive device intended to be attached to a powered handpiece to remove calculus deposits from teeth during dental cleaning and periodontal (gum) therapy. (b) Classification. Class II. ...
21 CFR 872.4840 - Rotary scaler.
Code of Federal Regulations, 2010 CFR
2010-04-01
... DENTAL DEVICES Surgical Devices § 872.4840 Rotary scaler. (a) Identification. A rotary scaler is an abrasive device intended to be attached to a powered handpiece to remove calculus deposits from teeth during dental cleaning and periodontal (gum) therapy. (b) Classification. Class II. ...
Development status of rotary engine at Toyo Kogyo. [for general aviation aircraft
NASA Technical Reports Server (NTRS)
Yamamoto, K.
1978-01-01
Progress in the development of rotary engines which use a thermal reactor as the primary part of the exhaust emission control system is reviewed. Possibilities of further improvements in fuel economy of future rotary engines are indicated.
Guelzow, A; Stamm, O; Martus, P; Kielbassa, A M
2005-10-01
To compare ex vivo various parameters of root canal preparation using a manual technique and six different rotary nickel-titanium (Ni-Ti) instruments (FlexMaster, System GT, HERO 642, K3, ProTaper, and RaCe). A total of 147 extracted mandibular molars were divided into seven groups (n = 21) with equal mean mesio-buccal root canal curvatures (up to 70 degrees), and embedded in a muffle system. All root canals were prepared to size 30 using a crown-down preparation technique for the rotary nickel-titanium instruments and a standardized preparation (using reamers and Hedströem files) for the manual technique. Length modifications and straightening were determined by standardized radiography and a computer-aided difference measurement for every instrument system. Post-operative cross-sections were evaluated by light-microscopic investigation and photographic documentation. Procedural errors, working time and time for instrumentation were recorded. The data were analysed statistically using the Kruskal-Wallis test and the Mann-Whitney U-test. No significant differences were detected between the rotary Ni-Ti instruments for alteration of working length. All Ni-Ti systems maintained the original curvature well, with minor mean degrees of straightening ranging from 0.45 degrees (System GT) to 1.17 degrees (ProTaper). ProTaper had the lowest numbers of irregular post-operative root canal diameters; the results were comparable between the other systems. Instrument fractures occurred with ProTaper in three root canals, whilst preparation with System GT, HERO 642, K3 and the manual technique resulted in one fracture each. Ni-Ti instruments prepared canals more rapidly than the manual technique. The shortest time for instrumentation was achieved with System GT (11.7 s). Under the conditions of this ex vivo study all Ni-Ti systems maintained the canal curvature, were associated with few instrument fractures and were more rapid than a standardized manual technique. ProTaper instruments created more regular canal diameters.
Liu, Sheng-Bo; Fan, Bin; Cheung, Gary S P; Peng, Bing; Fan, Ming-Wen; Gutmann, James L; Song, Ya-Ling; Fu, Qiang; Bian, Zhuan
2006-12-01
To compare the cleaning efficacy and shaping ability of engine-driven ProTaper and GT files, and manual preparation using K-Flexofile instruments in curved root canals of extracted human teeth. 45 canals of maxillary and mandibular molars with curvatures between 25 degrees and 40 degrees were divided into three groups. The groups were balanced with regard to the angle and the radius of canal curvature. Canals in each group were prepared to an apical size of 25 with either the rotary ProTaper or GT system, or manually with K-Flexofile using the modified double-flared technique. Irrigation was done with 2 mL 2.5% NaOCl after each instrument and, as the final rinse, 10 mL 2.5% NaOCl then 10 mL 17% EDTA and finally 5 mL distilled water. The double-exposure radiographic technique was used to examine for the presence of apical transportation. The time required to complete the preparation, as well as any change in working length after preparation were recorded. The roots were then grooved and split longitudinally. The amounts of debris and smear layer were evaluated at the apical, middle and coronal regions under the scanning electron microscope. Data were analyzed either parametrically with the F-test or non-parametrically using the Kruskal-Wallis test, where appropriate. Two GT files but none of the K-Flexofile and ProTaper instruments separated. For debris removal, the ProTaper group achieved a better result than GT (P < 0.05) but not the K-Flexofile group at all three regions (apical, middle and coronal). K-Flexofiles produced significantly less smear layer than ProTaper and GT files only in the middle third of the canal (P < 0.01). Both NiTi rotary instruments maintained the original canal shape better than the K-Flexofiles (P < 0.05) and required significantly less time to complete the preparation.
Input Power Characteristics of the Thyristor Variable Voltage Power Conditioner
DOT National Transportation Integrated Search
1973-11-01
A laboratory study was made of transformer and thyristor voltage control for speed control of a rotary induction motor. The test program consisted of two parts; the first dealing with measurements of the induction motor characteristics and the second...
Analysis of Apex Seal Friction Power Loss in Rotary Engines
NASA Technical Reports Server (NTRS)
Handschuh, Robert F.; Owen, A. Karl
2010-01-01
An analysis of the frictional losses from the apex seals in a rotary engine was developed. The modeling was initiated with a kinematic analysis of the rotary engine. Next a modern internal combustion engine analysis code was altered for use in a rotary engine to allow the calculation of the internal combustion pressure as a function of rotor rotation. Finally the forces from the spring, inertial, and combustion pressure on the seal were combined to provide the frictional horsepower assessment.
Buerger, Stephen; Marron, Lisa C.; Martinez, Michael A.; Spletzer, Barry Louis
2016-12-13
An electromechanical latch is described herein. The electromechanical latch is a dual-actuator latch, wherein a first actuator and a second actuator are driven with precise timing to move a first latch part relative to a second latch part, and vice versa. When the electromechanical latch is in a closed position, the first rotary latch part is positioned to prevent rotation of the second rotary latch part in a first direction. To transition the electromechanical latch from the closed position to an open position, the first actuator drives the first rotary latch part such that the second rotary latch part is able to rotate in the first direction. Thereafter, the second actuator drives the second rotary latch part in the first direction until the electromechanical latch is in the open position.
Laterally Translating Seal Carrier For A Drilling Mud Motor Sealed Bearing Assembly
Dietle, Lannie
1993-03-23
A sealing and lubrication assembly for rotating shafts intended for operation in an abrasive environment and wherein the rotary shaft may have lateral translation or excursion during its rotation. A housing receives the rotary shaft in bearing supporting relation and defines a lubricant chamber about the shaft. A seal carrier is movably positioned about the rotary shaft and has non-rotatable articulating or laterally translating relation with the housing. A high pressure rotary shaft seal is supported by the seal carrier and maintains bearing and sealing engagement with the rotary shaft during its lateral translation or excursion. The seal carrier is hydraulic force balanced and thus is not subject to pressure induced loads that might otherwise interfere with its articulation or lateral translation.
NASA Astrophysics Data System (ADS)
Gürtürk, Mert; Oztop, Hakan F.; Pambudi, Nugroho Agung
2018-04-01
In this study, the CFD analysis of the rotary kiln is carried out for examining effects of various parameters on energy consumption and efficiency of the rotary kiln. The flue gas recirculation using in many applications is a useful method for combusting of fuel unburned in the flue gas. Also, effects of flue gas recirculation on the combusting of fuel, operating temperature and efficiency of the rotary kiln are discussed in this study. The rotary kiln, which is considered in this study, is used in plaster plant. Two different CFD models were created and these models are compared according to many parameters such as temperature distribution, mixture fraction, the mass fraction of O2, CO, CO and CH4 in the combustion chamber. It is found that the plaster plant has a great potential for an increase in energy efficiency. Results obtained for producers of rotary kiln and burner will be useful for determining better design parameters.
An experimental study of the putative mechanism of a synthetic autonomous rotary DNA nanomotor
NASA Astrophysics Data System (ADS)
Dunn, K. E.; Leake, M. C.; Wollman, A. J. M.; Trefzer, M. A.; Johnson, S.; Tyrrell, A. M.
2017-03-01
DNA has been used to construct a wide variety of nanoscale molecular devices. Inspiration for such synthetic molecular machines is frequently drawn from protein motors, which are naturally occurring and ubiquitous. However, despite the fact that rotary motors such as ATP synthase and the bacterial flagellar motor play extremely important roles in nature, very few rotary devices have been constructed using DNA. This paper describes an experimental study of the putative mechanism of a rotary DNA nanomotor, which is based on strand displacement, the phenomenon that powers many synthetic linear DNA motors. Unlike other examples of rotary DNA machines, the device described here is designed to be capable of autonomous operation after it is triggered. The experimental results are consistent with operation of the motor as expected, and future work on an enhanced motor design may allow rotation to be observed at the single-molecule level. The rotary motor concept presented here has potential applications in molecular processing, DNA computing, biosensing and photonics.
NASA Astrophysics Data System (ADS)
Matsuoka, Ken; Esumi, Motoki; Ikeguchi, Ken Bryan; Kasahara, Jiro; Matsuo, Akiko; Funaki, Ikkoh
We developed a novel coaxial rotary valve for a multi-tube PDE. Since this single valve can supply three different gases (fuel, oxidizer and purge gas) into a combustor, the unification of the valve systems for three different gases is possible by using our newly designed valve. A PDRE system can be simple and lightweight by using this valve, and thus its thrust-weight ratio can be increased. We proposed the design of a multi-tube rotary-valved PDRE system by this rotary valve. Moreover, in preparation for a multi-tube rotary-valved PDRE, we carried out the multi-cycle operation experiment by the single-tube rotary-valved PDRE system. The combustion wave velocity was measured to confirm the operation of the PDRE system. Deflagration-to-detonation transition (DDT) was confirmed and DDT distance decreased under the condition of high operation frequency. In addition, a maximum operation frequency was 159 Hz.
A Summary of the Technical Pilot Selection Literature
2011-10-01
assigned to one of four groups. The apparatus tests specifically were designed to assess those causes that later were listed in the “coordination...with 15 min. allocated for each test (Staff Psychological Reseach Unit #1, 1945). One of the immediate practical problems with administering the...inventory and its eventual operational use in July 1943. One test in the Aircrew Classification Battery was designed to assess timesharing--the Rotary
Floating seal system for rotary devices
Banasiuk, Hubert A.
1983-01-01
This invention relates to a floating seal system for rotary devices to reduce gas leakage around the rotary device in a duct and across the face of the rotary device to an adjacent duct. The peripheral seal bodies are made of resilient material having a generally U-shaped cross section wherein one of the legs is secured to a support member and the other of the legs forms a contacting seal against the rotary device. The legs of the peripheral seal form an extended angle of intersection of about 10.degree. to about 30.degree. in the unloaded condition to provide even sealing forces around the periphery of the rotary device. The peripheral seal extends around the periphery of the support member except where intersected by radial seals which reduce gas leakage across the face of the rotary device and between adjacent duct portions. The radial seal assembly is fabricated from channel bars, the smaller channel bar being secured to the divider of the support member and a larger inverted rigid floating channel bar having its legs freely movable over the legs of the smaller channel bar forming therewith a tubular channel. A resilient flexible tube is positioned within the tubular channel for substantially its full length to reduce gas leakage across the tubular channel. A spacer extends beyond the face of the floating channel near each end of the floating channel a distance to provide desired clearance between the floating channel and the face of the rotary device.
Floating seal system for rotary devices
Banasiuk, H.A.
1983-08-23
This invention relates to a floating seal system for rotary devices to reduce gas leakage around the rotary device in a duct and across the face of the rotary device to an adjacent duct. The peripheral seal bodies are made of resilient material having a generally U-shaped cross section wherein one of the legs is secured to a support member and the other of the legs forms a contacting seal against the rotary device. The legs of the peripheral seal form an extended angle of intersection of about 10[degree] to about 30[degree] in the unloaded condition to provide even sealing forces around the periphery of the rotary device. The peripheral seal extends around the periphery of the support member except where intersected by radial seals which reduce gas leakage across the face of the rotary device and between adjacent duct portions. The radial seal assembly is fabricated from channel bars, the smaller channel bar being secured to the divider of the support member and a larger inverted rigid floating channel bar having its legs freely movable over the legs of the smaller channel bar forming therewith a tubular channel. A resilient flexible tube is positioned within the tubular channel for substantially its full length to reduce gas leakage across the tubular channel. A spacer extends beyond the face of the floating channel near each end of the floating channel a distance to provide desired clearance between the floating channel and the face of the rotary device. 5 figs.
Optimization of an enhanced ceramic micro-filter for concentrating E.coli in water
NASA Astrophysics Data System (ADS)
Zhang, Yushan; Guo, Tianyi; Xu, Changqing; Hong, Lingcheng
2017-02-01
Recently lower limit of detection (LOD) is necessary for rapid bacteria detection and analysis applications in clinical practices and daily life. A critical pre-conditioning step for these applications is bacterial concentration, especially for low level of pathogens. Sample volume can be largely reduced with an efficient pre-concentration process. Some approaches such as hollow-fiber ultra-filtration and electrokinetic technique have been applied to bacterial concentration. Since none of these methods can provide a concentrating method with a stable recovery efficiency, bacterial concentration still remains challenging Ceramic micro- filter can be used to concentrate the bacteria but the cross flow system keeps the bacteria in suspension. Similar harvesting bacteria using ultra-filtration showed an average recovery efficiency of 43% [1] and other studies achieved recovery rates greater than 50% [2]. In this study, an enhanced ceramic micro-filter with 0.14 μm pore size was proposed and demonstrated to optimize the concentration of E.coli. A high recovery rate (mean value >90%) and a high volumetric concentration ratio (>100) were achieved. Known quantities (104 to 106 CFU/ml) of E.coli cells were spiked to different amounts of phosphate buffered saline (0.1 to 1 L), and then concentrated to a final retentate of 5 ml to 10 ml. An average recovery efficiency of 95.3% with a standard deviation of 5.6% was achieved when the volumetric con- centration ratio was 10. No significant recovery rate loss was indicated when the volumetric concentration ratio reached up to 100. The effects of multiple parameters on E.coli recovery rate were also studied. The obtained results indicated that the optimized ceramic micro- filtration system can successfully concentrate E.coli cells in water with an average recovery rate of 90.8%.
Zheng, Siyang; Lin, Henry; Liu, Jing-Quan; Balic, Marija; Datar, Ram; Cote, Richard J; Tai, Yu-Chong
2007-08-31
This paper presents development of a parylene membrane microfilter device for single stage capture and electrolysis of circulating tumor cells (CTCs) in human blood, and the potential of this device to allow genomic analysis. The presence and number of CTCs in blood has recently been demonstrated to provide significant prognostic information for patients with metastatic breast cancer. While finding as few as five CTCs in about 7.5mL of blood (i.e., 10(10) blood cells in) is clinically significant, detection of CTCs is currently difficult and time consuming. CTC enrichment is performed by either gradient centrifugation of CTC based on their buoyant density or magnetic separation of epithelial CTC, both of which are laborious procedures with variable efficiency, and CTC identification is typically done by trained pathologists through visual observation of stained cytokeratin-positive epithelial CTC. These processes may take hours, if not days. Work presented here provides a micro-electro-mechanical system (MEMS)-based option to make this process simpler, faster, better and cheaper. We exploited the size difference between CTCs and human blood cells to achieve the CTC capture on filter with approximately 90% recovery within 10 min, which is superior to current approaches. Following capture, we facilitated polymerase chain reaction (PCR)-based genomic analysis by performing on-membrane electrolysis with embedded electrodes reaching each of the individual 16,000 filtering pores. The biggest advantage for this on-membrane in situ cell lysis is the high efficiency since cells are immobilized, allowing their direct contact with electrodes. As a proof-of-principle, we show beta actin gene PCR, the same technology can be easily extended to real time PCR for CTC-specific transcript to allow molecular identification of CTC and their further characterization.
Techniques Employed to Conduct Postshot Drilling at the former Nevada Test Site
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dekin, W D
2011-04-14
Postshot drilling provided essential data on the results of the underground nuclear tests conducted at the Nevada Test Site (NTS), now identified as the Nevada National Security Site (NNSS). It was the means by which samples from the zone of interest were obtained for radiochemical analysis. This handbook describes how Lawrence Livermore National Laboratory (LLNL) conducted postshot drilling operations at the NTS, and it provides a general understanding of the process. Postshot drilling is a specialized application of rotary drilling. Accordingly, this handbook gives a brief description of rotary drilling in Section 2 to acquaint the reader with the generalmore » subject before proceeding to the specialized techniques used in postshot drilling. In Section 3, the handbook describes the typical postshot drilling situation at the former NTS and the drilling methods used. Section 4 describes the typical sequence of operations in postshot drilling at the former NTS. Detailed information on special equipment and techniques is given in a series of appendices (A through F) at the end of the handbook.« less
The middeck 0-gravity dynamics experiment
NASA Technical Reports Server (NTRS)
Crawley, Edward F.; Vanschoor, Marthinus C.; Bokhour, Edward B.
1993-01-01
The Middeck 0-Gravity Dynamics Experiment (MODE), flown onboard the Shuttle STS-48 Mission, consists of three major elements: the Experiment Support Module, a dynamics test bed providing computer experiment control, analog signal conditioning, power conditioning, an operator interface consisting of a keypad and display, experiment electrical and thermal control, and archival data storage: the Fluid Test Article assembly, used to investigate the dynamics of fluid-structure interaction in 0-gravity; and the Structural Test Article for investigating the open-loop dynamics of structures in 0-gravity. Deployable, erectable, and rotary modules were assembled to form three one- and two-dimensional structures, in which variations in bracing wire and rotary joint preload could be introduced. Change in linear modal parameters as well as the change in nonlinear nature of the response is examined. Trends in modal parameters are presented as a function of force amplitude, joint preload, and ambient gravity. An experimental study of the lateral slosh behavior of contained fluids is also presented. A comparison of the measured earth and space results identifies and highlights the effects of gravity on the linear and nonlinear slosh behavior of these fluids.
F/A-18 and F-16 forebody vortex control, static and rotary-balance results
NASA Technical Reports Server (NTRS)
Kramer, Brian; Smith, Brooke
1994-01-01
The results from research on forebody vortex control on both the F/A-18 and the F-16 aircraft will be shown. Several methods of forebody vortex control, including mechanical and pneumatic schemes, will be discussed. The wind tunnel data includes both static and rotary balance data for forebody vortex control. Time lags between activation or deactivation of the pneumatic control and when the aircraft experiences the resultant forces are also discussed. The static (non-rotating) forces and pressures are then compared to similar configurations tested in the NASA Langley and DTRC Wind Tunnel, the NASA Ames 80'x120' Wind Tunnel, and in flight on the High Angle of Attack Research Vehicle (HARV).
Performance, optimization, and latest development of the SRI family of rotary cryocoolers
NASA Astrophysics Data System (ADS)
Dovrtel, Klemen; Megušar, Franc
2017-05-01
In this paper the SRI family of Le-tehnika rotary cryocoolers is presented (SRI401, SRI423/SRI421 and SRI474). The Stirling coolers cooling power range starts from 0.25W to 0.75W at 77K with available temperature range from 60K to 150K and are fitted to typical dewar detector sizes and powers supply voltages. The DDCA performance optimizing procedure is presented. The procedure includes cooler steady state performance mapping and optimization and cooldown optimization. The current cryogenic performance status and reliability evaluation method and figures are presented on the existing and new units. The latest improved SRI401 demonstrated MTTF close to 25'000 hours and the test is still on going.
NASA Technical Reports Server (NTRS)
Bihrle, W., Jr.; Mulcay, W.
1979-01-01
Aerodynamic characteristics obtained in a rotational flow environment utilizing a rotary balance located in the Langley spin tunnel are presented in plotted form for a 1/5 scale, single-engine, low-wing, general aviation airplane model. The configurations tested included the basic airplane, sixteen wing leading-edge modifications and lateral-directional control settings. Data are presented for all configurations without analysis for an angle of attack range of 8 deg to 35 deg and clockwise and counter-clockwise rotations covering an Omega b/2v range from 0 to 0.85. Also, data are presented above 35 deg of attack for some configurations.
A study of a direct-injection stratified-charge rotary engine for motor vehicle application
NASA Astrophysics Data System (ADS)
Kagawa, Ryoji; Okazaki, Syunki; Somyo, Nobuhiro; Akagi, Yuji
1993-03-01
A study of a direct-injection stratified-charge system (DISC), as applied to a rotary engine (RE) for motor vehicle usage, was undertaken. The goals of this study were improved fuel consumption and reduced exhaust emissions. These goals were thought feasible due to the high thermal efficiency associated with the DISC-RE. This was the first application of this technology to a motor vehicle engine. Stable ignition and ideal stratification systems were developed by means of numerical calculations, air-fuel mixture measurements, and actual engine tests. The use of DISC resulted in significantly improved fuel consumption and reduced exhaust emissions. The use of an exhaust gas recirculating system was studied and found to be beneficial in NOx reduction.
Torque-balanced vibrationless rotary coupling
Miller, Donald M.
1980-01-01
This disclosure describes a torque-balanced vibrationless rotary coupling for transmitting rotary motion without unwanted vibration into the spindle of a machine tool. A drive member drives a driven member using flexible connecting loops which are connected tangentially and at diametrically opposite connecting points through a free floating ring.
SITE TECHNOLOGY CAPSULE: SONOTECH PULSE COMBUSTION SYSTEM
Sonotech has targeted waste incineration as a potential application for this technology. Based on bench-scale rotary-kiln simulator tests, Sonotech proposed a demonstration under the SITE program to evaluate the Sonotech pulse combustion system on a larger scale at EPA's IRF in J...
Inan, U; Gurel, M
2017-02-01
Instrument fracture is a serious concern in endodontic practice. The aim of this study was to investigate the surface quality of new and used rotary nickel-titanium (NiTi) instruments manufactured by the traditional grinding process and twisting methods. Total 16 instruments of two rotary NiTi systems were used in this study. Eight Twisted Files (TF) (SybronEndo, Orange, CA, USA) and 8 Mtwo (VDW, Munich, Germany) instruments were evaluated. New and used of 4 experimental groups were evaluated using an atomic force microscopy (AFM). New and used instruments were analyzed on 3 points along a 3 mm. section at the tip of the instrument. Quantitative measurements according to the topographical deviations were recorded. The data were statistically analyzed with paired samples t-test and independent samples t-test. Mean root mean square (RMS) values for new and used TF 25.06 files were 10.70 ± 2.80 nm and 21.58 ± 6.42 nm, respectively, and the difference between them was statistically significant (P < 0.05). Mean RMS values for new and used Mtwo 25.06 files were 24.16 ± 9.30 nm and 39.15 ± 16.20 nm respectively, the difference between them also was statistically significant (P < 0.05). According to the AFM analysis, instruments produced by twisting method (TF 25.06) had better surface quality than the instruments produced by traditional grinding process (Mtwo 25.06 files).
Capar, Ismail Davut; Gok, Tuba; Orhan, Ezgi
2015-12-01
The purpose of the present study was to investigate the amount of root canal filling material after root canal filling removal with 360° rotary instrumentation or reciprocating motion with the same file sequence. Root canals of the 36 mandibular premolars were shaped with ProTaper Universal instruments up to size F2 and filled with corresponding single gutta-percha cone and sealer. The teeth were assigned to two retreatment groups (n = 18): group 1 360° rotational motion and group 2 reciprocating motion of ATR Tecnika motors (1310° clockwise and 578° counterclockwise). Retreatment procedure was performed with ProTaper Universal retreatment files with a sequence of D1-3 and ProTaper Universal F3 instruments. Total time required to remove filling material were recorded. Remaining filling material was examined under stereomicroscope at ×8 magnification. The data were analysed statistically using the Mann-Whitney U test, and testing was performed at 95 % confidence level (p < 0.05). There were no significant differences between the groups (p > 0.05) in terms of remaining filling material. The total time required for retreatment was shorter in 360° rotational motion group compared to reciprocating motion group (p < 0.05). Both continuous rotation and reciprocating motion showed similar effectiveness in terms of root canal filling material removal. Using ProTaper Universal retreatment instruments with reciprocating motion of ATR motor and conventional rotary motion have similar efficacy in root canal filling removal.
Fracture Resistance of Retreated Roots Using Different Retreatment Systems
Er, Kursat; Tasdemir, Tamer; Siso, Seyda Herguner; Celik, Davut; Cora, Sabri
2011-01-01
Objectives: This study was designed to evaluate the fracture resistance of retreated roots using different rotary retreatment systems. Methods: Forty eight freshly extracted human canine teeth with single straight root canals were instrumented sequentially increasing from size 30 to a size 55 using K-files whit a stepback technique. The teeth were randomly divided into three experimental and one control groups of 12 specimens each. The root canals were filled using cold lateral compaction of gutta-percha and AH Plus (Dentsply Detrey, Konstanz, Germany) sealer in experimental groups. Removal of gutta-percha was performed with the following devices and techniques: ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), R-Endo (Micro-Mega, Besançon, France), and Mtwo (Sweden & Martina, Padova, Italy) rotary retreatment systems. Control group specimens were only instrumented, not filled or retreated. The specimens were then mounted in copper rings, were filled with a self-curing polymethylmethacrylate resin, and the force required to cause vertical root fracture was measured using a universal testing device. The force of fracture of the roots was recorded and the results in the various groups were compared. Statistical analysis was accomplished by one-way ANOVA and a post hoc Tukey tests. Results: There were statistically significant differences between the control and experimental groups (P<.05). However, there were no significant differences among the experimental groups. Conclusions: Based on the results, all rotary retreatment techniques used in this in vitro study produced similar root weakness. PMID:21912497
Torsion and bending properties of shape memory and superelastic nickel-titanium rotary instruments.
Ninan, Elizabeth; Berzins, David W
2013-01-01
Recently introduced into the market are shape memory nickel-titanium (NiTi) rotary files. The objective of this study was to investigate the torsion and bending properties of shape memory files (CM Wire, HyFlex CM, and Phoenix Flex) and compare them with conventional (ProFile ISO and K3) and M-Wire (GT Series X and ProFile Vortex) NiTi files. Sizes 20, 30, and 40 (n = 12/size/taper) of 0.02 taper CM Wire, Phoenix Flex, K3, and ProFile ISO and 0.04 taper HyFlex CM, ProFile ISO, GT Series X, and Vortex were tested in torsion and bending per ISO 3630-1 guidelines by using a torsiometer. All data were statistically analyzed by analysis of variance and the Tukey-Kramer test (P = .05) to determine any significant differences between the files. Significant interactions were present among factors of size and file. Variability in maximum torque values was noted among the shape memory files brands, sometimes exhibiting the greatest or least torque depending on brand, size, and taper. In general, the shape memory files showed a high angle of rotation before fracture but were not statistically different from some of the other files. However, the shape memory files were more flexible, as evidenced by significantly lower bending moments (P < .008). Shape memory files show greater flexibility compared with several other NiTi rotary file brands. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Research and design of portable photoelectric rotary table data-acquisition and analysis system
NASA Astrophysics Data System (ADS)
Yang, Dawei; Yang, Xiufang; Han, Junfeng; Yan, Xiaoxu
2015-02-01
Photoelectric rotary table as the main test tracking measurement platform, widely use in shooting range and aerospace fields. In the range of photoelectric tracking measurement system, in order to meet the photoelectric testing instruments and equipment of laboratory and field application demand, research and design the portable photoelectric rotary table data acquisition and analysis system, and introduces the FPGA device based on Xilinx company Virtex-4 series and its peripheral module of the system hardware design, and the software design of host computer in VC++ 6.0 programming platform and MFC package based on class libraries. The data acquisition and analysis system for data acquisition, display and storage, commission control, analysis, laboratory wave playback, transmission and fault diagnosis, and other functions into an organic whole, has the advantages of small volume, can be embedded, high speed, portable, simple operation, etc. By photoelectric tracking turntable as experimental object, carries on the system software and hardware alignment, the experimental results show that the system can realize the data acquisition, analysis and processing of photoelectric tracking equipment and control of turntable debugging good, and measurement results are accurate, reliable and good maintainability and extensibility. The research design for advancing the photoelectric tracking measurement equipment debugging for diagnosis and condition monitoring and fault analysis as well as the standardization and normalization of the interface and improve the maintainability of equipment is of great significance, and has certain innovative and practical value.
Rotary endodontics in primary teeth – A review
George, Sageena; Anandaraj, S.; Issac, Jyoti S.; John, Sheen A.; Harris, Anoop
2015-01-01
Endodontic treatment in primary teeth can be challenging and time consuming, especially during canal preparation, which is considered one of the most important steps in root canal therapy. The conventional instrumentation technique for primary teeth remains the “gold-standard” over hand instrumentation, which makes procedures much more time consuming and adversely affects both clinicians and patients. Recently nickel–titanium (Ni–Ti) rotary files have been developed for use in pediatric endodontics. Using rotary instruments for primary tooth pulpectomies is cost effective and results in fills that are consistently uniform and predictable. This article reviews the use of nickel–titanium rotary files as root canal instrumentation in primary teeth. The pulpectomy technique is described here according to different authors and the advantages and disadvantages of using rotary files are discussed. PMID:26792964
Rotary endodontics in primary teeth - A review.
George, Sageena; Anandaraj, S; Issac, Jyoti S; John, Sheen A; Harris, Anoop
2016-01-01
Endodontic treatment in primary teeth can be challenging and time consuming, especially during canal preparation, which is considered one of the most important steps in root canal therapy. The conventional instrumentation technique for primary teeth remains the "gold-standard" over hand instrumentation, which makes procedures much more time consuming and adversely affects both clinicians and patients. Recently nickel-titanium (Ni-Ti) rotary files have been developed for use in pediatric endodontics. Using rotary instruments for primary tooth pulpectomies is cost effective and results in fills that are consistently uniform and predictable. This article reviews the use of nickel-titanium rotary files as root canal instrumentation in primary teeth. The pulpectomy technique is described here according to different authors and the advantages and disadvantages of using rotary files are discussed.
Submersible pumping system with heat transfer mechanism
Hunt, Daniel Francis Alan; Prenger, F. Coyne; Hill, Dallas D; Jankowski, Todd Andrew
2014-04-15
A submersible pumping system for downhole use in extracting fluids containing hydrocarbons from a well. In one embodiment, the pumping system comprises a rotary induction motor, a motor casing, one or more pump stages, and a cooling system. The rotary induction motor rotates a shaft about a longitudinal axis of rotation. The motor casing houses the rotary induction motor such that the rotary induction motor is held in fluid isolation from the fluid being extracted. The pump stages are attached to the shaft outside of the motor casing, and are configured to impart fluid being extracted from the well with an increased pressure. The cooling system is disposed at least partially within the motor casing, and transfers heat generated by operation of the rotary induction motor out of the motor casing.
Farid, Karim A; Mostafa, Yehya A; Kaddah, Mohammed A; El-Sharaby, Fouad Aly
2014-10-01
The aim of this study was to evaluate corticotomy-facilitated orthodontics (CFO) using piezosurgery versus conventional rotary instruments. Ten healthy adult male mongrel dogs of comparable age with a complete set of permanent dentition with average weights between 13-17 kilograms were used. CFO using conventional rotary instruments versus piezosurgery was performed on each dog in a split mouth design. For every dog, mandibular 2nd premolar retraction on each side was attempted after extracting 3rd premolars followed by corticotomy-facilitated orthodontics using conventional rotary surgical burs on the left side and an ultrasonic piezosurgery system on the right side of the same animal. Intraoral measurements of the rate of tooth movement were taken with a sliding caliper. Measurements were performed by the same operator at the time of surgery (appliance delivery) and every month for six months. The dogs were sacrificed after six months from initiation of tooth movement to evaluate the amount of tooth movement for both conventional rotary and piezosurgery corticotomy techniques. A statistically significantly higher mean amount of tooth movement for conventional rotary instrument versus the piezosurgery corticotomy technique was observed at all time intervals. Tooth movement was 1.6 times faster when CFO was done using conventional rotary instruments as compared to a piezosurgery device.
Nayak, Gurudutt; Singh, Inderpreet; Shetty, Shashit; Dahiya, Surya
2014-01-01
Objective: Apical extrusion of debris and irrigants during cleaning and shaping of the root canal is one of the main causes of periapical inflammation and postoperative flare-ups. The purpose of this study was to quantitatively measure the amount of debris and irrigants extruded apically in single rooted canals using two reciprocating and one rotary single file nickel-titanium instrumentation systems. Materials and Methods: Sixty human mandibular premolars, randomly assigned to three groups (n = 20) were instrumented using two reciprocating (Reciproc and Wave One) and one rotary (One Shape) single-file nickel-titanium systems. Bidistilled water was used as irrigant with traditional needle irrigation delivery system. Eppendorf tubes were used as test apparatus for collection of debris and irrigant. The volume of extruded irrigant was collected and quantified via 0.1-mL increment measure supplied on the disposable plastic insulin syringe. The liquid inside the tubes was dried and the mean weight of debris was assessed using an electronic microbalance. The data were statistically analysed using Kruskal-Wallis nonparametric test and Mann Whitney U test with Bonferroni adjustment. P-values less than 0.05 were considered significant. Results: The Reciproc file system produced significantly more debris compared with OneShape file system (P<0.05), but no statistically significant difference was obtained between the two reciprocating instruments (P>0.05). Extrusion of irrigant was statistically insignificant irrespective of the instrument or instrumentation technique used (P >0.05). Conclusions: Although all systems caused apical extrusion of debris and irrigant, continuous rotary instrumentation was associated with less extrusion as compared with the use of reciprocating file systems. PMID:25628665
Cyclic fatigue behavior of nickel-titanium dental rotary files in clinical simulated root canals.
Chi, Chih-Wen; Li, Chun-Chieh; Lin, Chun-Pin; Shin, Chow-Shing
2017-04-01
Dental rotary instruments can be applied in multiple conditions of canals, but unpredictable fatigue fracture may happen. This study evaluated the fatigue lives of two batches of nickel-titanium (NiTi) dental rotary files operating in clinically simulated root canals. Single-step cyclic fatigue tests were carried out to assess the performance of two batches of NiTi files (ProTaper and ProFile) in nine combinations of simulated canals (cylinder radii 5 mm, 7.5 mm, and 10 mm, and insertion angles 20°, 40°, and 60°). Two-step cyclic fatigue tests were carried out in simulated root canals with the same radius by using the following two sets of insertion angles: (20°, 40°), (20°, 60°), (40°, 20°), and (60°, 20°). Fracture surfaces were observed by scanning electron microscopy. The single-step cyclic fatigue results showed that cyclic fatigue lives of the files decreased with increasing insertion angles or decreasing cylinder radius. The ProFile #25 .04 file was more fatigue resistant than the ProTaper F2 file. In two-step cyclic fatigue tests, the total fatigue lives were usually more than 100% when the files operated at a lower strain and then at a higher strain. By scanning electron microscopy, a larger area of fatigue striation corresponded to a longer fatigue life. Cyclic fatigue life can be influenced by the strains and geometries of files. The fatigue life was prolonged when the files operated at a lower strain and then at a higher strain. However, the fatigue life was shortened if the loading sequence was reversed. Copyright © 2016. Published by Elsevier B.V.
Sacchetti, Rossella; De Luca, Giovanna; Guberti, Emilia; Zanetti, Franca
2015-01-01
Municipal tap water is increasingly treated at the point of use (POU) to improve the acceptability and palatability of its taste. The aim of this study was to assess the bacteriologic and nutritional characteristics of tap water treated at the point of use in residential healthcare facilities for the elderly. Two types of POU devices were used: microfiltered water dispensers (MWDs) and reverse-osmosis water dispensers (ROWDs). All samples of water entering the devices and leaving them were tested for the bacteriological parameters set by Italian regulations for drinking water and for opportunistic pathogens associated with various infections in healthcare settings; in addition, the degree of mineralization of the water was assessed. The results revealed widespread bacterial contamination in the POU treatment devices, particularly from potentially pathogenic species. As expected, the use of ROWDs led to a decrease in the saline content of the water. In conclusion, the use of POU treatment in healthcare facilities for the elderly can be considered advisable only if the devices are constantly and carefully maintained. PMID:26371025
Sacchetti, Rossella; De Luca, Giovanna; Guberti, Emilia; Zanetti, Franca
2015-09-09
Municipal tap water is increasingly treated at the point of use (POU) to improve the acceptability and palatability of its taste. The aim of this study was to assess the bacteriologic and nutritional characteristics of tap water treated at the point of use in residential healthcare facilities for the elderly. Two types of POU devices were used: microfiltered water dispensers (MWDs) and reverse-osmosis water dispensers (ROWDs). All samples of water entering the devices and leaving them were tested for the bacteriological parameters set by Italian regulations for drinking water and for opportunistic pathogens associated with various infections in healthcare settings; in addition, the degree of mineralization of the water was assessed. The results revealed widespread bacterial contamination in the POU treatment devices, particularly from potentially pathogenic species. As expected, the use of ROWDs led to a decrease in the saline content of the water. In conclusion, the use of POU treatment in healthcare facilities for the elderly can be considered advisable only if the devices are constantly and carefully maintained.
Wegmann, Markus; Michen, Benjamin; Luxbacher, Thomas; Fritsch, Johannes; Graule, Thomas
2008-03-01
The purpose of this study was to test the feasibility of modifying commercial microporous ceramic bacteria filters to promote adsorption of viruses. The internal surface of the filter medium was coated with ZrO(2) nanopowder via dip-coating and heat-treatment in order to impart a filter surface charge opposite to that of the target viruses. Streaming potential measurements revealed a shift in the isoelectric point from pH <3 to between pH 5.5 and 9, respectively. While the base filter elements generally exhibited only 75% retention with respect to MS2 bacteriophages, the modified elements achieved a 7log removal (99.99999%) of these virus-like particles. The coating process also increased the specific surface area of the filters from approximately 2m(2)/g to between 12.5 and 25.5m(2)/g, thereby also potentially increasing their adsorption capacity. The results demonstrate that, given more development effort, the chosen manufacturing process has the potential to yield effective virus filters with throughputs superior to those of current virus filtration techniques.
A mechanical energy harvested magnetorheological damper with linear-rotary motion converter
NASA Astrophysics Data System (ADS)
Chu, Ki Sum; Zou, Li; Liao, Wei-Hsin
2016-04-01
Magnetorheological (MR) dampers are promising to substitute traditional oil dampers because of adaptive properties of MR fluids. During vibration, significant energy is wasted due to the energy dissipation in the damper. Meanwhile, for conventional MR damping systems, extra power supply is needed. In this paper, a new energy harvester is designed in an MR damper that integrates controllable damping and energy harvesting functions into one device. The energy harvesting part of this MR damper has a unique mechanism converting linear motion to rotary motion that would be more stable and cost effective when compared to other mechanical transmissions. A Maxon motor is used as a power generator to convert the mechanical energy into electrical energy to supply power for the MR damping system. Compared to conventional approaches, there are several advantages in such an integrated device, including weight reduction, ease in installation with less maintenance. A mechanical energy harvested MR damper with linear-rotary motion converter and motion rectifier is designed, fabricated, and tested. Experimental studies on controllable damping force and harvested energy are performed with different transmissions. This energy harvesting MR damper would be suitable to vehicle suspensions, civil structures, and smart prostheses.
Shahi, Shahriar; Asghari, Vahideh; Rahimi, Saeed; Lotfi, Mehrdad; Samiei, Mohammad; Yavari, Hamidreza; Shakouie, Sahar; Nezafati, Saeed
2016-01-01
Introduction: The aim of the present study was to compare the effect of two different rotary instruments on postoperative pain in teeth with asymptomatic irreversible pulpitis. Methods and Materials: A total of 78 mandibular first and second molars were divided into two groups (n=39) and their root canal preparation was carried out with either RaCe or ProTaper rotary instruments. All the subjects underwent one-visit root canal treatment and the severity of postoperative pain was evaluated using visual analog scale (VAS) at 4-, 12-, 24-, 48- and 72-h and 1-week intervals. In addition, the need for taking analgesics was recorded. Data were analyzed with the repeated-measures ANOVA and the Mann-Whitney U test was used for two-by-two comparison. Statistical significance was set at 0.05. Results: Comparison of mean pain severity between the two groups at various postoperative intervals did not reveal any significant differences (P=0.10). The difference in amount of analgesics taken by each groups was not statistically significant (P=0.25). Conclusion: There were no significant differences in the postoperative pain reported between the two groups; which indicates the clinical acceptability of both systems. PMID:26843876
Apical extrusion of debris and irrigant using hand and rotary systems: A comparative study
Ghivari, Sheetal B; Kubasad, Girish C; Chandak, Manoj G; Akarte, NR
2011-01-01
Aim: To evaluate and compare the amount of debris and irrigant extruded quantitatively by using two hand and rotary nickel–titanium (Ni–Ti) instrumentation techniques. Materials and Methods: Eighty freshly extracted mandibular premolars having similar canal length and curvature were selected and mounted in a debris collection apparatus. After each instrument change, 1 ml of distilled water was used as an irrigant and the amount of irrigant extruded was measured using the Meyers and Montgomery method. After drying, the debris was weighed using an electronic microbalance to determine its weight. Statistical analysis used: The data was analyzed statistically to determine the mean difference between the groups. The mean weight of the dry debris and irrigant within the group and between the groups was calculated by the one-way ANOVA and multiple comparison (Dunnet D) test. Results: The step-back technique extruded a greater quantity of debris and irrigant in comparison to other hand and rotary Ni–Ti systems. Conclusions: All instrumentation techniques extrude debris and irrigant, it is prudent on the part of the clinician to select the instrumentation technique that extrudes the least amount of debris and irrigant, to prevent a flare-up phenomena. PMID:21814364
A metering rotary nanopump for microfluidic systems
Darby, Scott G.; Moore, Matthew R.; Friedlander, Troy A.; Schaffer, David K.; Reiserer, Ron S.; Wikswo, John P.
2014-01-01
We describe the design, fabrication, and testing of a microfabricated metering rotary nanopump for the purpose of driving fluid flow in microfluidic devices. The miniature peristaltic pump is composed of a set of microfluidic channels wrapped in a helix around a central cam shaft in which a non-cylindrical cam rotates. The cam compresses the helical channels to induce peristaltic flow as it is rotated. The polydimethylsiloxane (PDMS) nanopump design is able to produce intermittent delivery or removal of several nanoliters of fluid per revolution as well as consistent continuous flow rates ranging from as low as 15 nL/min to above 1.0 µL/min. At back pressures encountered in typical microfluidic devices, the pump acts as a high impedance flow source. The durability, biocompatibility, ease of integration with soft-lithographic fabrication, the use of a simple rotary motor instead of multiple synchronized pneumatic or mechanical actuators, and the absence of power consumption or fluidic conductance in the resting state all contribute to a compact pump with a low cost of fabrication and versatile implementation. This suggests that the pump design may be useful for a wide variety of biological experiments and point of care devices. PMID:20959938
NASA Astrophysics Data System (ADS)
Zhou, Peng; Peng, Zhike; Chen, Shiqian; Yang, Yang; Zhang, Wenming
2018-06-01
With the development of large rotary machines for faster and more integrated performance, the condition monitoring and fault diagnosis for them are becoming more challenging. Since the time-frequency (TF) pattern of the vibration signal from the rotary machine often contains condition information and fault feature, the methods based on TF analysis have been widely-used to solve these two problems in the industrial community. This article introduces an effective non-stationary signal analysis method based on the general parameterized time-frequency transform (GPTFT). The GPTFT is achieved by inserting a rotation operator and a shift operator in the short-time Fourier transform. This method can produce a high-concentrated TF pattern with a general kernel. A multi-component instantaneous frequency (IF) extraction method is proposed based on it. The estimation for the IF of every component is accomplished by defining a spectrum concentration index (SCI). Moreover, such an IF estimation process is iteratively operated until all the components are extracted. The tests on three simulation examples and a real vibration signal demonstrate the effectiveness and superiority of our method.
Design and Development of Sequential Rotary Valve
NASA Technical Reports Server (NTRS)
D’Orsi, Nicholas; Castillo, Priscilla
2017-01-01
Valves are used to regulate the flow of fluids through systems. This rotary valve's main purpose is to fill, pressurize, empty, and vent three smaller tanks with the supply of one larger tank. Many different designs are being taken into consideration, which are each at different stages of development. The furthest along uses three ball valves on a common shaft to open and close their respective ports as the shaft completes one full rotation or cycle. We were tasked with advancing this design to its first test as a plastic model for flow verification, as well as sizing and ordering the necessary O-rings and fasteners. A motor will also be sized to satisfy the torque requirements, and will then be programmed using a Raspberry Pi to rotate the shaft at the calculated speed and dwelling times needed to fill each tank equally. In addition, we have also been advancing designs that use a camshaft and poppets. These are earlier on in their development, currently being sized to replicate the expected flow patterns of the rotary ball valve. Expected outcomes of this valve include bi-directionality, successful sealing under pressure, and accurate cycling.
The study of heat penetration of kimchi soup on stationary and rotary retorts.
Cho, Won-Il; Park, Eun-Ji; Cheon, Hee Soon; Chung, Myong-Soo
2015-03-01
The aim of this study was to determine the heat-penetration characteristics using stationary and rotary retorts to manufacture Kimchi soup. Both heat-penetration tests and computer simulation based on mathematical modeling were performed. The sterility was measured at five different positions in the pouch. The results revealed only a small deviation of F 0 among the different positions, and the rate of heat transfer was increased by rotation of the retort. The thermal processing of retort-pouched Kimchi soup was analyzed mathematically using a finite-element model, and optimum models for predicting the time course of the temperature and F 0 were developed. The mathematical models could accurately predict the actual heat penetration of retort-pouched Kimchi soup. The average deviation of the temperature between the experimental and mathematical predicted model was 2.46% (R(2)=0.975). The changes in nodal temperature and F 0 caused by microbial inactivation in the finite-element model predicted using the NISA program were very similar to that of the experimental data of for the retorted Kimchi soup during sterilization with rotary retorts. The correlation coefficient between the simulation using the NISA program and the experimental data was very high, at 99%.
The Study of Heat Penetration of Kimchi Soup on Stationary and Rotary Retorts
Cho, Won-Il; Park, Eun-Ji; Cheon, Hee Soon; Chung, Myong-Soo
2015-01-01
The aim of this study was to determine the heat-penetration characteristics using stationary and rotary retorts to manufacture Kimchi soup. Both heat-penetration tests and computer simulation based on mathematical modeling were performed. The sterility was measured at five different positions in the pouch. The results revealed only a small deviation of F0 among the different positions, and the rate of heat transfer was increased by rotation of the retort. The thermal processing of retort-pouched Kimchi soup was analyzed mathematically using a finite-element model, and optimum models for predicting the time course of the temperature and F0 were developed. The mathematical models could accurately predict the actual heat penetration of retort-pouched Kimchi soup. The average deviation of the temperature between the experimental and mathematical predicted model was 2.46% (R2=0.975). The changes in nodal temperature and F0 caused by microbial inactivation in the finite-element model predicted using the NISA program were very similar to that of the experimental data of for the retorted Kimchi soup during sterilization with rotary retorts. The correlation coefficient between the simulation using the NISA program and the experimental data was very high, at 99%. PMID:25866751
Osteotomy in direct sinus lift. A comparative study of the rotary technique and ultrasound
Peñarrocha-Diago, Miguel; Sanchez-Recio, Cristina; Peñarrocha-Oltra, David; Romero-Millán, Javier
2012-01-01
Purpose: The present study investigates sinus membrane rupture in direct maxillary sinus lift with the rotary technique and with ultrasound, examining the survival of implants placed after sinus augmentation, and analyzing the bone gain obtained after the operation and 12 months after placement of the prosthetic restoration. Material and Methods: A retrospective study was made of 45 patients requiring maxillary sinus lift or augmentation for implant-prosthetic rehabilitation. Use was made of the hand piece and ostectomy drills for the rotary technique, and of specific tips for ultrasound. The implant success criteria were based on those developed by Buser. The bone gain obtained as a result of sinus lift was calculated from the postoperative panoramic X-rays. Results: A total of 57 direct elevations of the maxillary sinus were carried out: 32 with the rotary technique and 25 with ultrasound. Perforations of Schneider’s membrane with the rotary technique and ultrasound occurred in 7% and 1.7% of the cases, respectively, with membrane integrity being preserved in 91.2%. Of the 100 implants placed, 5 failed after one year of follow-up in the rotary technique group, while one implant failed in the ultrasound group. The rotary technique in turn afforded a bone gain of 5.9 mm, versus 6.7 mm with ultrasound. Conclusions: Perforations of the membrane sinusal in direct lift were more frequent with the rotary technique (7%) than with ultrasound (1.7%). Implant survival and bone gain were both greater when ultrasound was used. Key words:Bone sectioning, maxillary sinus augmentation, piezosurgery. PMID:22143735
This report describes the implementation and testing of control measures to reduce airborne asbestos generated by the drilling of asbestos-containing flooring materials, an OSHA Class III asbestos maintenance activity. Bosch 11224 and 11222 rotary drills were fitted with shrouds ...
A test program was performed at the Environmental Protection Agency Incineration Research Facility to study the effectiveness of incineration at low-to-moderate temperatures in decontaminating soils containing organic compounds with different volatilities (boiling points). The da...
NASA Technical Reports Server (NTRS)
Taylor, Deneen; Enriquez, Carlos; McCann, David; McFatter, Justin
2010-01-01
The Solar Alpha Rotary Joint (SARJ) is a single-axis pointing mechanism used to orient the solar power generating arrays relative to the sun for the International Space Station (ISS). Approximately 83 days after its on-orbit installation, one of the two SARJ mechanisms aboard the ISS began to exhibit high current draw. Later inspections via Extravehicular Activity (EVA) discovered that the case hardened steel race ring on the outboard side of the joint had extensive damage to one of its three rolling surfaces. A far-reaching investigation of the anomaly was undertaken, comprising metallurgical inspections, coupon tests, traction kinematics tests, detailed bearing measurements, and thermal and structural analyses. The investigation found that the race ring damage had been caused by high bearing edge stresses that resulted from inadequate lubrication of the rolling contact. The profile of the roller bearings and the metallurgical properties of the race ring were also found to be significant contributing factors.
Passive control of a biventricular assist device with compliant inflow cannulae.
Gregory, Shaun David; Pearcy, Mark John; Timms, Daniel
2012-08-01
Rotary ventricular assist device (VAD) support of the cardiovascular system is susceptible to suction events due to the limited preload sensitivity of these devices. This may be of particular concern with rotary biventricular support (BiVAD) where the native, flow balancing Starling response is diminished in both ventricles. The reliability of sensor and sensorless-based control systems which aim to control VAD flow based on preload has limitations, and, thus, an alternative solution is desired. This study introduces a compliant inflow cannula (CIC) which could improve the preload sensitivity of a rotary VAD by passively altering VAD flow depending on preload. To evaluate the design, both the CIC and a standard rigid inflow cannula were inserted into a mock circulation loop to enable biventricular heart failure support using configurations of atrial and ventricular inflow, and arterial outflow cannulation. A range of left (LVAD) and right VAD (RVAD) rotational speeds were tested as well as step changes in systemic/pulmonary vascular resistance to alter relative preloads, with resulting flow rates recorded. Simulated suction events were observed, particularly at higher VAD speeds, during support with the rigid inflow cannula, while the CIC prevented suction events under all circumstances. The compliant section passively restricted its internal diameter as preload was reduced, which increased the VAD circuit resistance and thus reduced VAD flow. Therefore, a CIC could potentially be used as a passive control system to prevent suction events in rotary left, right, and biventricular support. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Subramaniam, Priya; Tabrez, T A; Babu, K L Girish
2013-01-01
To assess the microflora of root canals in primary molars following use of rotary NiTi files and conventional hand NiTi and stainless steel files. This randomized clinical trial consisted of a total of 60 first and second primary molars requiring root canal treatment, who were selected from children aged 5-9 years. Based on type of root canal instrumentation, the teeth were randomly assigned to three groups of twenty teeth each; Group A: Rotary NiTi files, Group B: Hand NiTi files and Group C: Hand stainless steel files. Following administration of local anesthesia, isolation with rubber dam was carried out. For the purpose of instrumentation and sampling, the palatal canal of maxillary molars and the distal canal of mandibular molars were selected. Prior to sampling, the orifices of other canals in these teeth were sealed, so as to prevent any contamination. Instrumentation was carried out in each group using respective instruments along with intermittent saline irrigation. Root canal samples were obtained both before and after instrumentation, using sterile absorbent paper points and transferred to a sterile vial with transport fluid. Serial dilutions were prepared and cultured on suitable agar media. Both aerobic and anaerobic microbial counts were made. Data obtained was subjected to statistical analysis using Wilcoxon signed rank test and one-way Analysis of variance. In all three groups, there was a significant reduction in both aerobic and anaerobic mean microbial count following root canal instrumentation. (p < 0.001). Rotary NiTi files were as efficient as conventional hand instruments in significantly reducing the root canal microflora.
Martins, Renata Castro; Seijo, Marília Oliveira Saraiva; Ferreira, Efigênia Ferreira; Paiva, Saul Martins; Ribeiro Sobrinho, Antônio Paulino
2012-01-01
This study evaluated the perceptions of Brazilian undergraduate dental students about the endodontic treatments performed using NiTi rotary instruments and hand stainless steel. Data were collected using a questionnaire administered to undergraduate dental students enrolled in endodontic disciplines. The students were divided into 3 groups: G1, students who had treated straight canals with SS hand instruments; G2, students who had treated curved canals with SS hand instruments; and G3, students who had treated both straight and curved canals with NiTi rotary instruments. The number of endodontic treatments performed, types of treated teeth, students' learning, time spent, encountered difficulties, quality of endodontic treatment and characteristics of the employed technique were analyzed. There was a 91.3% rate of return for the questionnaires. Mandibular molars were the most frequently treated teeth, followed by maxillary incisors. The Kruskal-Wallis test showed no differences in learning (p=0.528) or in the characteristics of the technique employed (p=0.560) among the three groups. G3 students performed a greater number of endodontic treatments (p<0.001) in a smaller time (p<0.001) than did G1 and G2 students. Difficulties were reported primarily by students in G2 and G3 compared with G1 (p=0.048). The quality of endodontic treatments differed only between G1 and G2 (p=0.045). The use of NiTi rotary instruments should be included in undergraduate dental curriculum, contributing to the increase of patients assisted and consequently to improve the clinical experience of the students.
MEMS based shock pulse detection sensor for improved rotary Stirling cooler end of life prediction
NASA Astrophysics Data System (ADS)
Hübner, M.; Münzberg, M.
2018-05-01
The widespread use of rotary Stirling coolers in high performance thermal imagers used for critical 24/7 surveillance tasks justifies any effort to significantly enhance the reliability and predictable uptime of those coolers. Typically the lifetime of the whole imaging device is limited due to continuous wear and finally failure of the rotary compressor of the Stirling cooler, especially due to failure of the comprised bearings. MTTF based lifetime predictions, even based on refined MTTF models taking operational scenario dependent scaling factors into account, still lack in precision to forecast accurately the end of life (EOL) of individual coolers. Consequently preventive maintenance of individual coolers to avoid failures of the main sensor in critical operational scenarios are very costly or even useless. We have developed an integrated test method based on `Micro Electromechanical Systems', so called MEMS sensors, which significantly improves the cooler EOL prediction. The recently commercially available MEMS acceleration sensors have mechanical resonance frequencies up to 50 kHz. They are able to detect solid borne shock pulses in the cooler structure, originating from e.g. metal on metal impacts driven by periodical forces acting on moving inner parts of the rotary compressor within wear dependent slack and play. The impact driven transient shock pulse analyses uses only the high frequency signal <10kHz and differs therefore from the commonly used broadband low frequencies vibrational analysis of reciprocating machines. It offers a direct indicator of the individual state of wear. The predictive cooler lifetime model based on the shock pulse analysis is presented and results are discussed.
The rotary subwoofer: a controllable infrasound source.
Park, Joseph; Garcés, Milton; Thigpen, Bruce
2009-04-01
The rotary subwoofer is a novel acoustic transducer capable of projecting infrasonic signals at high sound pressure levels. The projector produces higher acoustic particle velocities than conventional transducers which translate into higher radiated sound pressure levels. This paper characterizes measured performance of a rotary subwoofer and presents a model to predict sound pressure levels.
Repulsive force actuated rotary micromirror
NASA Astrophysics Data System (ADS)
He, Siyuan; Ben Mrad, Ridha
2004-09-01
In this paper, a novel repulsive force based rotary micromirror is proposed. A repulsive force is produced in the rotary micromirror and the mirror plate is pushed up and away from the substrate. Therefore the rotation angle of the micromirror is not limited to the space underneath the mirror plate and thus the "pull-in" effect is completely circumvented. The novel rotary micromirror can achieve a large rotation angle with a large mirror plate. In addition the novel micromirror has a very simple structure and can be fabricated by standard surface micromachining technology. Numerical simulation is used to verify the working principle of the novel micromirror. A prototype of the novel rotary micromirror is fabricated by a commercially available surface microfabrication process called MUMPs. The prototype has a mirror size of 300μm x 300μm. The experimental measurements show that the prototype can achieve a mechanical rotation of 2.25 degrees (an optical angle of 4.5 degrees) at a driving voltage of 170 volts. A conventional surface micromachined attractive force based rotary micromirror of the same size can only achieve an angle of 0.1~0.2 degree.
Arya, Ashtha; Bali, Dildeep; Grewal, Mandeep S
2011-07-01
To compare the cleaning efficiency of manual and rotary instrumentation in the apical third of the root canal system. In group 1 (n=10), instrumentation was performed with stainless steel K-file; in group 2 (n=10), it was done with hand ProTaper files; and in group 3 (n=10), instrumentation was done with ProTaper rotary. Distilled water was used for irrigation. The apical third was sectioned transversally and histologically processed. The cross sections were examined under optic microscope and debris was measured using Motic software. Instrumentation with stainless steel K-files showed minimum amount of debris, followed by ProTaper hand files, and rotary ProTaper files were least effective with maximum amount of debris; however, there were no significant differences between the three experimental groups. Both the manual and rotary instrumentation are relatively efficient in cleaning the apical third of the root canal system and the choice between manual and rotary instrumentation should depend on case to case basis.
NASA Astrophysics Data System (ADS)
Rammage, Robert L.
1990-10-01
A device for sequentially testing the plurality of connectors in a wiring harness is disclosed. The harness is attached to the tester by means of adapter cables and a rotary switch is used to sequentially, individually test the connectors by passing a current through the connector. If the connector is unbroken, a light will flash to show it is electrically sound. The adapters allow a large number of cable configurations to be tested using a single tester configuration.
The machined surface of magnesium AZ31 after rotary turning at air cooling condition
NASA Astrophysics Data System (ADS)
Akhyar, G.; Purnomo, B.; Hamni, A.; Harun, S.; Burhanuddin, Y.
2018-04-01
Magnesium is a lightweight metal that is widely used as an alternative to iron and steel. Magnesium has been applied in the automotive industry to reduce the weight of a component, but the machining process has the disadvantage that magnesium is highly flammable because it has a low flash point. High temperature can cause the cutting tool wear and contributes to the quality of the surface roughness. The purpose of this study is to obtain the value of surface roughness and implement methods of rotary cutting tool and air cooling output vortex tube cooler to minimize the surface roughness values. Machining parameters that is turning using rotary cutting tool at speed the workpiece of (Vw) 50, 120, 160 m/min, cutting speed of rotary tool of (Vt) 25, 50, 75 m/min, feed rate of (f) 0.1, 0.15, 0.2 mm/rev, and depth of cut of 0.3 mm. Type of tool used is a carbide tool diameter of 16 mm and air cooling pressure of 6 bar. The results show the average value of the lowest surface roughness on the speed the workpiece of 80 m/min, cutting speed of rotary tool of 50 m/min, feed rate of 0.2 mm/rev, and depth of cut of 0.3 mm. While the average value of the highest surface roughness on the speed the workpiece of 160 m/min, cutting speed of rotary tool of 50 m/min, feed rate of 0.2 mm/rev, and depth of cut of 0.3 mm. The influence of machining parameters concluded the higher the speed of the workpiece the surface roughness value higher. Otherwise the higher cutting speed of rotary tool then the lower the surface roughness value. The observation on the surface of the rotary tool, it was found that no uniform tool wear which causes non-uniform surface roughness. The use of rotary cutting tool contributing to lower surface roughness values generated.
Protein fouling in microfiltration: deposition mechanism as a function of pressure for different pH.
Velasco, C; Ouammou, M; Calvo, J I; Hernández, A
2003-10-01
The influence of applied pressure on the fouling mechanism during bovine serum albumin (BSA) dead-end microfiltration (MF) has been investigated for a polyethersulfone acidic negatively charged membrane (ICE-450) from Pall Co. BSA solutions at pH values of 4, 5 (almost equal to the protein isoelectric point, IEP), and 6 were microfiltered through the membrane at different applied transmembrane pressures. Results have been analyzed in terms of the usual blocking filtration laws and a substantial change in the fouling mechanism was observed as the pressure was increased, this change can be related to the specific membrane-protein and protein-protein interactions.
Rotary Stirling-Cycle Engine And Generator
NASA Technical Reports Server (NTRS)
Chandler, Joseph A.
1990-01-01
Proposed electric-power generator comprises three motor generators coordinated by microprocessor and driven by rotary Stirling-cycle heat engine. Combination offers thermodynamic efficiency of Stirling cycle, relatively low vibration, and automatic adjustment of operating parameters to suit changing load on generator. Rotary Stirling cycle engine converts heat to power via compression and expansion of working gas between three pairs of rotary pistons on three concentric shafts in phased motion. Three motor/generators each connected to one of concentric shafts, can alternately move and be moved by pistons. Microprocessor coordinates their operation, including switching between motor and generator modes at appropriate times during each cycle.
Mahesh, MC; Bhandary, Shreetha
2017-01-01
Introduction Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. Aim This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. Materials and Methods In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Results Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files significantly more number of cracks were seen at WL than WL-1 (p=0.057 for RaCe files and p=0.087 for K3 files). Conclusion There was no statistical significance between stainless steel hand files and rotary files in terms of crack formation. Instrumentation length had a significant effect on the formation of cracks when rotary files were used. Using rotary instruments 1 mm short of apical foramen caused lesser crack formation. But, there was no statistically significant difference in number of cracks formed with hand files at two instrumentation levels. PMID:28274036
Devale, Madhuri R; Mahesh, M C; Bhandary, Shreetha
2017-01-01
Stresses generated during root canal instrumentation have been reported to cause apical cracks. The smaller, less pronounced defects like cracks can later propagate into vertical root fracture, when the tooth is subjected to repeated stresses from endodontic or restorative procedures. This study evaluated occurrence of apical cracks with stainless steel hand files, rotary NiTi RaCe and K3 files at two different instrumentation lengths. In the present in vitro study, 60 mandibular premolars were mounted in resin blocks with simulated periodontal ligament. Apical 3 mm of the root surfaces were exposed and stained using India ink. Preoperative images of root apices were obtained at 100x using stereomicroscope. The teeth were divided into six groups of 10 each. First two groups were instrumented with stainless steel files, next two groups with rotary NiTi RaCe files and the last two groups with rotary NiTi K3 files. The instrumentation was carried out till the apical foramen (Working Length-WL) and 1 mm short of the apical foramen (WL-1) with each file system. After root canal instrumentation, postoperative images of root apices were obtained. Preoperative and postoperative images were compared and the occurrence of cracks was recorded. Descriptive statistical analysis and Chi-square tests were used to analyze the results. Apical root cracks were seen in 30%, 35% and 20% of teeth instrumented with K-files, RaCe files and K3 files respectively. There was no statistical significance among three instrumentation systems in the formation of apical cracks (p=0.563). Apical cracks were seen in 40% and 20% of teeth instrumented with K-files; 60% and 10% of teeth with RaCe files and 40% and 0% of teeth with K3 files at WL and WL-1 respectively. For groups instrumented with hand files there was no statistical significance in number of cracks at WL and WL-1 (p=0.628). But for teeth instrumented with RaCe files and K3 files significantly more number of cracks were seen at WL than WL-1 (p=0.057 for RaCe files and p=0.087 for K3 files). There was no statistical significance between stainless steel hand files and rotary files in terms of crack formation. Instrumentation length had a significant effect on the formation of cracks when rotary files were used. Using rotary instruments 1 mm short of apical foramen caused lesser crack formation. But, there was no statistically significant difference in number of cracks formed with hand files at two instrumentation levels.
Manjunatha, M; Annapurna, Kini; Sudhakar, V; Sunil Kumar, VC; Hiremath, Vinay Kumar; Shah, Ankur
2013-01-01
Introduction: The aim of any root canal treatment is to achieve a canal free of micro organisms, residual pulp remnants, debris and smear layer for the long term success of the procedure. Manual and automated instrumentation techniques along with proper irrigation regime is used to arrive at the aforementioned goal. Many authors focused on the preparation capabilities of various manual and rotary instruments but very few investigators stressed on the actual cleaning abilities of these instruments. Aims and objectives: This study was undertaken to evaluate the cleaning efficiency of manual K flex files and rotary Pro File systems in the root canals using a scanning electron microscope. Material and Methods:Thirty single rooted mandibular first premolars were divided into two groups and randomized (the manual group-M and the ProFile group-P) with respect to the preparation technique. The Manual group was hand instrumented with stainless steel K- Flexofiles by means of a conventional filing technique. The Pro File group was instrumented according to the manufacturer's instructions using a rotary handpiece. All canals were shaped and cleaned under frequent irrigation with EDTA. Final irrigation was carried out with 3 mL of normal saline solution to neutralize the action of the irrigant. The roots were split, one half of each tooth was selected for further SEM technique analysis and examined under the scanning electron microscope. The canal walls were quantitatively evaluated for the amount of debris and smear layer. The apical, middle and coronal regions of the canal surface, were graded (1-5) for debris and smear layer. A statistical analysis was performed using a Mann-Whitney Rank Sum test. ProFile performed least effective cleaning. Manual K-Flexofiles led to a grooved pattern. Results and Conclusion: A statistically significant difference was observed (p<0.05) between the two instrumentation techniques concerning the amount of debris and smear layer at the apical level. The manually filed canals had less debris and smear layer than those using a rotary technique. It was concluded from this study that none of the instrumentation techniques employed, produced the canal walls which were free of surface debris and smear layer. The manual instrumentation technique was better in cleaning the canals compared to the ProFile rotary Ni-Ti instruments despite the step-back technique used for manual instrumentation. How to cite this article: Manjunatha M, Kini A, Sudhakar V, Sunil K V C, Hiremath V K, Shah A. Smear Layer Evaluation on Root Canal Preparation with Manual and Rotary Techniques using EDTA as an Irrigant: A Scanning Electron Microscopy Study. J Int Oral Health 2013; 5(1):66-78. PMID:24155580
Farid, Huma; Khan, Farhan Raza; Rahman, Munawar
2013-03-01
This study aimed to compare the frequency of ProTaper rotary instrument fracture with rotary (conventional) and hybrid (rotary and hand files) canal preparation techniques. Secondary objectives were to determine whether there was an association of ProTaper file fracture with the canal curvature and to compare the mean time required for canal preparation in the two techniques. An in vitro experiment was conducted on 216 buccal canals of extracted maxillary and mandibular first molars. After creating an access cavity and a glide path for each canal, a periapical radiograph was taken and the canal curvature was measured with Schneider's technique. The canals were then randomly divided into Group A (rotary technique) and Group B (hybrid technique). The length of ProTaper files were measured before and after each canal preparation. Time taken for each canal preparation was recorded. A total of seven ProTaper files fractured in Group A (P=0.014) in canals with a curvature >25 degrees (P<0.001). The mean time taken for preparation of the root canals was 104.04 sec (± 55.7 sec) in Group A versus 122.88 sec (± 41.67 sec) in Group B (P=0.007). In the teeth studied, the hybrid technique of root canal preparation with ProTaper rotary files, although time consuming, was safer in canals having a curvature greater than 25 degrees.
Field testing advanced geothermal turbodrill (AGT). Phase 1 final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maurer, W.C.; Cohen, J.H.
1999-06-01
Maurer Engineering developed special high-temperature geothermal turbodrills for LANL in the 1970s to overcome motor temperature limitations. These turbodrills were used to drill the directional portions of LANL`s Hot Dry Rock Geothermal Wells at Fenton Hill, New Mexico. The Hot Dry Rock concept is to drill parallel inclined wells (35-degree inclination), hydraulically fracture between these wells, and then circulate cold water down one well and through the fractures and produce hot water out of the second well. At the time LANL drilled the Fenton Hill wells, the LANL turbodrill was the only motor in the world that would drill atmore » the high temperatures encountered in these wells. It was difficult to operate the turbodrills continuously at low speed due to the low torque output of the LANL turbodrills. The turbodrills would stall frequently and could only be restarted by lifting the bit off bottom. This allowed the bit to rotate at very high speeds, and as a result, there was excessive wear in the bearings and on the gauge of insert roller bits due to these high rotary speeds. In 1998, Maurer Engineering developed an Advanced Geothermal Turbodrill (AGT) for the National Advanced Drilling and Excavation Technology (NADET) at MIT by adding a planetary speed reducer to the LANL turbodrill to increase its torque and reduce its rotary speed. Drilling tests were conducted with the AGT using 12 1/2-inch insert roller bits in Texas Pink Granite. The drilling tests were very successful, with the AGT drilling 94 ft/hr in Texas Pink Granite compared to 45 ft/hr with the LANL turbodrill and 42 ft/hr with a rotary drill. Field tests are currently being planned in Mexico and in geothermal wells in California to demonstrate the ability of the AGT to increase drilling rates and reduce drilling costs.« less
1981-01-01
chamber, with a 0-60,000 RPM, 300 HP dynamometer, was selected as the test facility. A rotary transformer ( brushless ) torque sensor, using air /oil... brushless ) of 100 and 500 in-lb torque ranges were selected from Lebow Associates, Inc. of Troy, Michigan. Special air / oil mist lubrication for the...period August 1979 - October 1980 I Approved for public release; distribution unlimited. _ DTIC AERO PROPULSION LABORATORY AIR FORCE WRIGHT AERONAUTICAL
Abnormal Vestibulo-Ocular Reflexes in Autism: A Potential Endophenotype
2013-06-01
Annual Report for 15 May 2012 – 14 May 2013 8 Table 5. Summary of Gaze Evoked Nystagmus Tests (no differences between groups) Target...abnormalities of vestibulo-ocular reflexes (VOR) in Autism Spectrum Disorder (ASD). Specific Aim 1: Characterize horizontal VOR post-rotary nystagmus ...without optokinetic feedback using a velocity step test. We hypothesize that in ASD vertical eye movement intrusions during horizontal nystagmus will
Viana, A C D; Pereira, E S J; Bahia, M G A; Buono, V T L
2013-09-01
To investigate the influence of cyclic flexural and torsional loading on the flexibility of ProTaper Universal, K3 and EndoSequence nickel-titanium instruments, in view of the hypothesis that these types of loading would decrease the flexibility of the selected NiTi rotary files. The instruments evaluated were S2 and F1 ProTaper Universal, sizes 20 and 25, .06 taper K3, and sizes 20 and 25, .06 taper EndoSequence. Flexibility was determined by 45° bending tests according to ISO 3630-1 specification. Values of the bending moment (MB ) obtained with new instruments were considered as the control group (CG). Bending tests were then conducted in instruments previously fatigued to one-fourth and three-fourths of their average fatigue life (fatigue groups, FG¼ and FG¾), as well as after cyclic torsional loading (torsional group, TG). Fatigue tests were carried out in a bench device that allowed the files to rotate freely inside an artificial canal with an angle of curvature of 45° and a radius of 5 mm. Cyclic torsional loading tests were performed that entailed rotating the instrument from zero angular deflection to 180° and then returning to zero applied torque in 20 cycles. Data were analysed using one-way analysis of variance at a significance level of 5%. Simulated clinical use by means of flexural fatigue tests did not affect the flexibility of the instruments, except for a significant increase in flexibility observed in a few instruments (P < 0.05). In addition, comparative statistical analyses between the values of MB measured in new instruments and after cyclic torsional loading showed no significant differences between them (P > 0.05). The flexibility of rotary ProTaper Universal, K3 and EndoSequence NiTi instruments, measured in bending tests, was not adversely affected by simulated clinical use in curved root canals. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
SUPERFUND TREATABILITY CLEARINGHOUSE: TRIAL BURN TEST REPORT, PART 1 - DATA SUMMARIES
This treatability study summary reports on the results of a trial burn of pesticide-contaminated soil from the Aberdeen, NC Superfund site. The trial burn using the Vesta mobile rotary kiln incinerator was designed to demonstrate that this system can destroy the pestici...
40 CFR 63.1383 - Monitoring requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... facility must prepare for each glass-melting furnace, rotary spin manufacturing line, and flame attenuation... initial performance tests. (b)(1) Where a baghouse is used to control PM emissions from a glass-melting... baghouse), the system instrumentation and alarm may be shared among the monitors. (v) A triboelectric bag...
Math modeling and computer mechanization for real time simulation of rotary-wing aircraft
NASA Technical Reports Server (NTRS)
Howe, R. M.
1979-01-01
Mathematical modeling and computer mechanization for real time simulation of rotary wing aircraft is discussed. Error analysis in the digital simulation of dynamic systems, such as rotary wing aircraft is described. The method for digital simulation of nonlinearities with discontinuities, such as exist in typical flight control systems and rotor blade hinges, is discussed.
33 CFR 100.914 - Trenton Rotary Roar on the River, Trenton, MI.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Trenton Rotary Roar on the River, Trenton, MI. 100.914 Section 100.914 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.914 Trenton Rotary Roar on...
Advanced rotary engine studies
NASA Technical Reports Server (NTRS)
Jones, C.
1980-01-01
A review of rotary engine developments relevant to a stratified charge rotary aircraft engine is presented. Advantages in module size and weight, fuel efficiency, reliability, and multi-fuel capability are discussed along with developments in turbocharging, increased mean effective pressure, improved apex seal/trochoid wear surfacing materials, and high strength and temperature aluminum casting alloys. A carbureted prototype aircraft engine is also described.
Determination of the spin and recovery characteristics of a typical low-wing general aviation design
NASA Technical Reports Server (NTRS)
Tischler, M. B.; Barlow, J. B.
1980-01-01
The equilibrium spin technique implemented in a graphical form for obtaining spin and recovery characteristics from rotary balance data is outlined. Results of its application to recent rotary balance tests of the NASA Low-Wing General Aviation Aircraft are discussed. The present results, which are an extension of previously published findings, indicate the ability of the equilibrium method to accurately evaluate spin modes and recovery control effectiveness. A comparison of the calculated results with available spin tunnel and full scale findings is presented. The technique is suitable for preliminary design applications as determined from the available results and data base requirements. A full discussion of implementation considerations and a summary of the results obtained from this method to date are presented.
Yan, Hong; Ren, Min; Yin, Xing-Zhe; Zhao, Shu-Yan; Zhang, Cheng-Fei
2008-04-01
To evaluate the deformation of ProTaper rotary instruments using in root canals of different curvature in vitro. Extracted first mandibular molars were divided into two experimental groups according to the curvature of mesial buccal canals: group A with moderate curvature and group B with severe curvature. Only the mesial buccal canals of all these teeth were prepared with 6 sets of new ProTaper rotary instruments individually. Additionally, the control group was established with a set of new ProTaper rotary instruments. After finishing each canal preparation, the instruments accompanied by control were examined under the stereomicroscope by an inspector without knowing the group. If distortion, unwinding, abrasion or fracture occurred within one set of instruments, then the whole set was disposed. The sets without problems were in use until 30 times. After 5, 10, 20 times canal preparation, S1, F1 files without deformation under stereomicroscope were examined under scanning electron microscope (SEM). Deformation of ProTaper rotary instruments happened after 12 times in group A and after 7 times in group B. In these two experimental groups, microcracks were found increasing with the times of use under SEM in the instruments without deformation under stereomicroscope. The microcracks on tip of instruments were deep in the early use and became smoother after 10 times. Similar changes happened on knife-edge of instruments, and the microcracks extended over the edge after 20 times use. Root canals with severe curvature tend to damage ProTaper rotary instruments more frequently than moderately curved canals. ProTaper rotary instruments are appropriate to treat less than 7 root canals with severe curvature or 12 root canals with moderate curvature. Stereomicroscope is recommended to detect early damages on Ni-Ti rotary instruments, for preventing instruments fracture in clinic.
Resonance phenomenon of the ATP motor as an ultrasensitive biosensor.
Wang, Peirong; Zhang, Xiaoguang; Zhang, Xu; Wang, Xia; Li, Xueren; Yue, Jiachang
2012-09-28
We designed a rotary biosensor as a damping effector, with the rotation of the F(0)F(1)-ATPase driven by Adenosine Triphosphate (ATP) synthesis being indicated by the fluorescence intensity and a damping effect force being induced by the binding of an RNA molecule to its probe on the rotary biosensor. We found that the damping effect could contribute to the resonance phenomenon and energy transfer process of our rotary biosensor in the liquid phase. This result indicates that the ability of the rotary motor to operate in the vibration harmonic mode depends on the environmental conditions and mechanism in that a few molecules of the rotary biosensor could induce all of the sensor molecules to fluoresce together. These findings contribute to the theory study of the ATPase motor and future development of biosensors for ultrasensitive detection. Copyright © 2012 Elsevier Inc. All rights reserved.
Rotary adsorbers for continuous bulk separations
Baker, Frederick S [Oak Ridge, TN
2011-11-08
A rotary adsorber for continuous bulk separations is disclosed. The rotary adsorber includes an adsorption zone in fluid communication with an influent adsorption fluid stream, and a desorption zone in fluid communication with a desorption fluid stream. The fluid streams may be gas streams or liquid streams. The rotary adsorber includes one or more adsorption blocks including adsorbent structure(s). The adsorbent structure adsorbs the target species that is to be separated from the influent fluid stream. The apparatus includes a rotary wheel for moving each adsorption block through the adsorption zone and the desorption zone. A desorption circuit passes an electrical current through the adsorbent structure in the desorption zone to desorb the species from the adsorbent structure. The adsorbent structure may include porous activated carbon fibers aligned with their longitudinal axis essentially parallel to the flow direction of the desorption fluid stream. The adsorbent structure may be an inherently electrically-conductive honeycomb structure.
Stewart, Alastair G.; Sobti, Meghna; Harvey, Richard P.; Stock, Daniela
2013-01-01
Rotary ATPases are molecular rotary motors involved in biological energy conversion. They either synthesize or hydrolyze the universal biological energy carrier adenosine triphosphate. Recent work has elucidated the general architecture and subunit compositions of all three sub-types of rotary ATPases. Composite models of the intact F-, V- and A-type ATPases have been constructed by fitting high-resolution X-ray structures of individual subunits or sub-complexes into low-resolution electron densities of the intact enzymes derived from electron cryo-microscopy. Electron cryo-tomography has provided new insights into the supra-molecular arrangement of eukaryotic ATP synthases within mitochondria and mass-spectrometry has started to identify specifically bound lipids presumed to be essential for function. Taken together these molecular snapshots show that nano-scale rotary engines have much in common with basic design principles of man made machines from the function of individual “machine elements” to the requirement of the right “fuel” and “oil” for different types of motors. PMID:23369889
40 CFR 63.2241 - What are the work practice requirements and how must I meet them?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Products Compliance Options, Operating Requirements, and Work Practice Requirements § 63.2241 What are the...) If you have a dry rotary dryer, you may choose to designate your dry rotary dryer as a green rotary dryer and meet the more stringent compliance options and operating requirements in § 63.2240 for green...
Split Coil Forms for Rotary Transformers
NASA Technical Reports Server (NTRS)
Mclyman, C. W. T.
1982-01-01
Split cores for rotor and stator windings of rotary transformer mounted around their respective coils (which are in bobbins) and cemented together. This arrangement simplifies winding of stator coil to go in a slot in inner diameter of stator coil. One practical application of rotary transformers fabricated according to this technique is for centrifuges, in which conventional sliprings are of uncertain reliability.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-07
...-AA00 Safety Zone; Rotary Club of Fort Lauderdale New River Raft Race, New River, Fort Lauderdale, FL... Fort Lauderdale, Florida during the Rotary Club of Fort Lauderdale New River Raft Race. The race is... safety of race participants, participant vessels, spectators, and the general public during the 550 yard...
Rotary Series Elastic Actuator
NASA Technical Reports Server (NTRS)
Ihrke, Chris A. (Inventor); Mehling, Joshua S. (Inventor); Parsons, Adam H. (Inventor); Griffith, Bryan Kristian (Inventor); Radford, Nicolaus A. (Inventor); Permenter, Frank Noble (Inventor); Davis, Donald R. (Inventor); Ambrose, Robert O. (Inventor); Junkin, Lucien Q. (Inventor)
2013-01-01
A rotary actuator assembly is provided for actuation of an upper arm assembly for a dexterous humanoid robot. The upper arm assembly for the humanoid robot includes a plurality of arm support frames each defining an axis. A plurality of rotary actuator assemblies are each mounted to one of the plurality of arm support frames about the respective axes. Each rotary actuator assembly includes a motor mounted about the respective axis, a gear drive rotatably connected to the motor, and a torsion spring. The torsion spring has a spring input that is rotatably connected to an output of the gear drive and a spring output that is connected to an output for the joint.
Rotary series elastic actuator
NASA Technical Reports Server (NTRS)
Ihrke, Chris A. (Inventor); Mehling, Joshua S. (Inventor); Parsons, Adam H. (Inventor); Griffith, Bryan Kristian (Inventor); Radford, Nicolaus A. (Inventor); Permenter, Frank Noble (Inventor); Davis, Donald R. (Inventor); Ambrose, Robert O. (Inventor); Junkin, Lucien Q. (Inventor)
2012-01-01
A rotary actuator assembly is provided for actuation of an upper arm assembly for a dexterous humanoid robot. The upper arm assembly for the humanoid robot includes a plurality of arm support frames each defining an axis. A plurality of rotary actuator assemblies are each mounted to one of the plurality of arm support frames about the respective axes. Each rotary actuator assembly includes a motor mounted about the respective axis, a gear drive rotatably connected to the motor, and a torsion spring. The torsion spring has a spring input that is rotatably connected to an output of the gear drive and a spring output that is connected to an output for the joint.
Kinematic control model for light weighting mechanism of excavator attached to rotary working device
NASA Astrophysics Data System (ADS)
Lee, Choongho; Lee, Sangsik; Cho, Youngtae; Im, Kwanghee
2007-07-01
An excavator attached to a rotary working device is used principally in industrial work. In particular, they are used in the building industry and public works. This research concerns the rotary automatic control of an excavator attached to a rotary working device. The drilling excavator is used in the crushed stone industry and the dragline excavation system is employed in the construction industry. Cases of the excavator's use in agriculture have been the subject of a relatively few studies. However, several modified excavator designs have been released in recent years. Applied excavator products are primarily utilized under relatively severe environmental conditions. In this study, we focus on the uses of an excavator in agricultural work. The readjustment of arable land and the reduction of weeds in agricultural applications both require skilled hand-operation of the machines. As such workers have been shown to develop problems with regard to working posture and proper positioning while laboring, a more appropriate excavator design may prove useful in such applications. Therefore, this pilot study is focused primarily on the rotary automatic control of an excavator attached to a rotary working device, and will adapt smart materials to the excavator applications for developing redesigned excavator having a light weight. The excavator is attached to a rotary working device on a normal excavator's platform, and the position and orientation of the mechanism between the joints and the rotary working device was determined. Simulations were also conducted of the excavator attached to the rotary working device. With an eye toward the use of this mechanism in agricultural work, we also conducted a set of kinematic analyses. The rotary working device was assumed to have 3 DOF, and was comprised of 5 links. Computer simulations were also conducted using the developed excavator model. In order to adequately evaluate the possible performance of such a system, kinetic analysis, simulation with a soil model, FEM analysis with structural strength analysis, and changes to the smart materials with high rigidity will be required in the future. In addition, experiment and analysis of a prototype, durability experiments, and analyses utilizing S-N curves will be necessary, as well further research into the overall reliability of such a product.
This report presents the results of a treatability study of rotary kiln incineration of a synthetic "Superfund soil" bearing a wide range of chemical contaminants typically occurring at Superfund sites. This surrogate soil is referred to as a synthetic analytical reference ...
Kumar, Rahul; Khambete, Neha; Patil, Suvarna; Hoshing, Upendra; Medha, Ashish; Shetty, Roshan
2013-09-01
This in vitro investigation examined the effect of early coronal flaring (CF) and late CF on the working length (WL) in curved root canals. The objective of this study was to determine if canal length is altered as a result of CF in curved canals of molar roots. The conditions compared were combinations of (a) stainless steel hand files using Gates Glidden (G. G.) drills (SS) versus nickel-titanium rotary files (Ni-Ti); and (b) early CF (flaring completed before WL determination) versus late CF (flaring completed after WL determination). Selected were 90 canals of extracted maxillary or mandibular first molars (mesial root of mandibular molars and the mesiobuccal root of the maxillary molars) from three groups. CF was accomplished for the SS group using G. G. drills and for the Ni-Ti group using rotary ProTaper and Hero Shaper files. WL was determined by a digital vernier caliper before CF, immediately after CF, and again after canal preparation. A repeated measures analysis of variance (ANOVA) test and a Tukey's multiple prosthoc test were used for this study. Results indicated that WL decreased for all canals as a result of canal preparation. The mean decrease in WL was significantly greater for the SS group (-0.77 ± 0.42 mm) than for the Ni-Ti groups (-0.33 mm ± 0.44). Less change in WL occurred in all groups when initial WL was determined after CF. WL in curved canals consistently decreases during the course of instrumentation. Clinician should keep this in mind for better treatment outcome.
Fatigue testing of a NiTi rotary instrument. Part 1: Strain-life relationship.
Cheung, G S P; Darvell, B W
2007-08-01
To examine the fatigue behaviour using a strain-life approach, and to determine the effect of water on the fatigue life of a NiTi rotary instrument. Instruments of one brand of NiTi engine-file (size 25, ProFile 0.04 and 0.06) were subjected to rotational bending either in air or under water, the number of revolutions to fracture (N(f)) being recorded using an optical counter and an electronic break-detection circuit. The effective surface strain amplitude (epsilon(a)) for each specimen was determined from the curvature of the instrument (on a photograph) and the diameter of the fracture cross-section (from a scanning electron micrograph of the fracture surface). Strain was plotted against fatigue life and the low-cycle fatigue (LCF) region identified. Values were examined using two-way analysis of variance for difference between various instrument-environment combinations. A total of 212 instruments were tested. A strain-life relationship typical of metals was found. N(f) declined with an inverse power function dependence on epsilon(a). A fatigue limit was present at about 0.7% strain. The apparent fatigue-ductility exponent, a material constant for the LCF life of metals, was found to be between -0.45 and -0.55. There was a significant effect of the environmental condition on the LCF life, water being more detrimental than air. The fatigue behaviour of NiTi rotary instrument is typical of most metals, provided that the analysis is based on the surface strain amplitude, and showed a high-cycle and a LCF region. The LCF life is adversely affected by water.
Kaul, Rudra; Farooq, Riyaz; Kaul, Vibhuti; Khateeb, Shafayat Ullah; Purra, Aamir Rashid; Mahajan, Roopali
2014-01-01
Introduction: The aim of the present study was to comparatively evaluate the physical surface changes and incidence of separation in rotary nickel-titanium (NiTi) instruments using scanning electron microscope (SEM). Methods and Materials: A total number of 210 freshly extracted human maxillary and mandibular first molars were selected and distributed between three groups. Three different systems of rotary NiTi instruments, namely ProFile (PF), RaCe (RC) and Twisted File (TF), were used to prepare the canals using crown-down technique. All instruments were evaluated by means of SEM with 500× and 1500× magnifications, at four different stages; before use, after preparation of 7 and 14 canals and after instrument separation. Photomicrographs were also taken. The data was analyzed using the Kruskal-Wallis test and the level of significance was set at 0.001. It was found that H (HAT matrix) was 15.316 with 2 degrees of freedom. Moreover the various groups were compared using the Student-Newman-Keuls test with P<0.05 and it was found that all groups were significantly different. Results: RC showed the maximum wear of the surface followed by TF (P<0.05). PF showed the minimum wear except for its tip. There was no correlation between electropolishing and file fracture. Insignificant difference was observed in the mean number of canals shaped by PF and TF before their separation. Conclusion: Clinically, TF performance was superior, followed by PF then RC. RC fracture rate was the greatest after preparing the least number of canals. PMID:25031595
Analysis of Wind Tunnel Oscillatory Data of the X-31A Aircraft
NASA Technical Reports Server (NTRS)
Smith, Mark S.
1999-01-01
Wind tunnel oscillatory tests in pitch, roll, and yaw were performed on a 19%-scale model of the X-31A aircraft. These tests were used to study the aerodynamic characteristics of the X-31A in response to harmonic oscillations at six frequencies. In-phase and out-of-phase components of the aerodynamic coefficients were obtained over a range of angles of attack from 0 to 90 deg. To account for the effect of frequency on the data, mathematical models with unsteady terms were formulated by use of two different indicial functions. Data from a reduced set of frequencies were used to estimate model parameters, including steady-state static and dynamic stability derivatives. Both models showed good prediction capability and the ability to accurately fit the measured data. Estimated static stability derivatives compared well with those obtained from static wind tunnel tests. The roll and yaw rate derivative estimates were compared with rotary-balanced wind tunnel data and theoretical predictions. The estimates and theoretical predictions were in agreement at small angles of attack. The rotary-balance data showed, in general, acceptable agreement with the steady-state derivative estimates.
Brantley, W A; Luebke, N H; Luebke, F L; Mitchell, J C
1994-05-01
A laboratory study was performed on Gates Glidden and Peeso drills to determine the incidence of shaft fracture when a bending deflection was superimposed on the rotating drills. Samples of sizes #1 to #6 stainless steel Gates Glidden drills, sizes #1 to #6 stainless steel and carbon steel-type P Peeso drills, and sizes #009 to #023 carbon steel-type B-1 Peeso drills from each of two manufacturers were evaluated with a unique apparatus that applied a 2-mm bending deflection while rotating the instruments. The apparatus did not restrict movement of the bur head during rotation. The test drills were rotated at 2500, 4000, and 7000 revolutions per minute, and the number of revolutions at failure was recorded. Scanning electron microscopic observations established that the stainless steel Gates Glidden and Peeso drills failed by ductile fracture, whereas the carbon steel Peeso drills failed by brittle fracture. Instrument fracture was always near the handpiece shank with this test, and the length of the fractured drills was measured from the working tip. It is recommended that this additional test be adopted to determine fatigue properties of engine-driven rotary endodontic instruments in establishing international performance standards.
NASA Astrophysics Data System (ADS)
Vanheyden, L.; Evertz, E.
1980-12-01
Compression type air/water heat pumps were developed for domestic heating systems rated at 20 to 150 kW. The heat pump is driven either by a reciprocating piston or rotary piston engine modified to operate on natural gas. Particular features of natural gas engines as prime movers, such as waste heat recovery and variable speed, are stressed. Two systems suitable for heat pump operation were selected from among five different mass produced car engines and were modified to incorporate reciprocating piston compressor pairs. The refrigerants used are R 12 and R 22. Test rig data transferred to field conditions show that the fuel consumption of conventional boilers can be reduced by 50% and more by the installation of engine driven heat pumps. Pilot heat pumps based on a 1,600 cc reciprocating piston engine were built for heating four two-family houses. Pilot pump operation confirms test rig findings. The service life of rotary piston and reciprocating piston engines was investigated. The tests reveal characteristic curves for reciprocating piston engines and include exhaust composition measurements.
Short Pulse Switches for Airborne High Power Supplies
1973-10-01
IB 8. Rotary Mechanical Switch 20 9. Mechanical Switch, Essential Elements 24 10. Motor , Torsion Bar Electrodynamic Drive 28 11. Fast Acting...Gas Valve 31 12. Motor Test, Conductance, and Torque 33 13. Measured Motor Characteristics 34 14. Motor Structural Test Sample 36 15. Motor ...Fig. 42. Fig. 43. Fig. 44. Fig. 45. Fig. 46. Fig. 47. Fig. 48. Mechanical Switch 49 Arcing Contacts 51 Nonarcing Contacts 53 Motor
Poggio, Claudio; Dagna, Alberto; Chiesa, Marco; Scribante, Andrea; Beltrami, Riccardo; Colombo, Marco
2014-12-30
The purpose of the present study was to investigate the cleaning efficacy of 2 different nickel-titanium (NiTi) rotary systems: a new single system Reciproc compared with the rotary full sequence Mtwo. The amount of debris and the morphology of smear layer were the parameters for the evaluation of the cleanliness of root canals. The null hypothesis of the study was that there would be no significant difference in debris scores and smear layer scores between the 2 systems. Forty single-rooted freshly extracted teeth were selected and divided into 2 groups. For each group, all root canals were shaped with 2 different NiTi instruments (Mtwo and Reciproc) and irrigated with 5.25% NaOCl and 17% ethylenediaminetetraacetic acid (EDTA) solutions by 3 trained operators. Specimens were fractured longitudinally and prepared for scanning electron microscopy (SEM) analysis at a standard magnification of ×5,000. The presence/absence of smear layer and the presence/absence of debris at the coronal, middle and apical third of each canal were evaluated using two 5-step scales for scores. Numeric data were analyzed using the Kruskal-Wallis and Mann-Whitney U statistical tests, and significance was set at a P value <0.05. This study revealed significant differences among the various groups. The Mtwo group presented significantly lower smear layer scores than the Reciproc group (P<0.01) in the middle and apical third of the canal. Conventional continuous rotary NiTi instruments associated with 5.25% NaOCl and 17% EDTA solutions seem to be better for obtaining clean dentinal canal walls. Reciprocating instruments leave a higher quantity of smear layer which covers dentinal walls and dentinal tubules.
Chi, Chih-Wen; Deng, Yu-Lun; Lee, Jyh-Wei; Lin, Chun-Pin
2017-05-01
Dental nickel-titanium (NiTi) rotary instruments are widely used in endodontic therapy because they are efficient with a higher success rate. However, an unpredictable fracture of instruments may happen due to the surface characteristics of imperfection (or irregularity). This study assessed whether a novel surface treatment could increase fatigue fracture resistance of dental NiTi rotary instruments. A 200- or 500-nm thick Ti-zirconium-boron (Ti-Zr-B) thin film metallic glass was deposited on ProTaper Universal F2 files using a physical vapor deposition process. The characteristics of coating were analyzed by scanning electron microscopy, transmission electron microscopy, and X-ray diffractometry. In cyclic fatigue tests, the files were performed in a simulated root canal (radius=5 mm, angulation=60°) under a rotating speed of 300rpm. The fatigue fractured cross sections of the files were analyzed with their fractographic performances through scanning electron microscopy images. The amorphous structure of the Ti-Zr-B coating was confirmed by transmission electron microscopy and X-ray diffractometry. The surface of treated files presented smooth morphologies without grinding irregularity. For the 200- and 500-nm surface treatment groups, the coated files exhibited higher resistance of cyclic fatigue than untreated files. In fractographic analysis, treated files showed significantly larger crack-initiation zone; however, no significant differences in the areas of fatigue propagation and catastrophic fracture were found compared to untreated files. The novel surface treatment of Ti-Zr-B thin film metallic glass on dental NiTi rotary files can effectively improve the fatigue fracture resistance by offering a smooth coated surface with amorphous microstructure. Copyright © 2016. Published by Elsevier B.V.
Spagnuolo, G; Ametrano, G; D'Antò, V; Rengo, C; Simeone, M; Riccitiello, F; Amato, M
2012-12-01
To evaluate the effects of repeated autoclave sterilization cycles on surface topography of conventional nickel-titanium ( NiTi ) and titanium nitride ( TiN )-coated rotary instruments. A total of 60 NiTi rotary instruments, 30 ProTaper (Dentsply Maillefer) and 30 TiN -coated AlphaKite (Komet/Gebr. Brasseler), were analysed. Instruments were evaluated in the as-received condition and after 1, 5 and 10 sterilization cycles. After sterilization, the samples were observed using scanning electron microscope (SEM), and surface chemical analysis was performed on each instrument with energy dispersive X-ray spectroscopy (EDS). Moreover, the samples were analysed by atomic force microscopy (AFM), and roughness average (Ra) and the root mean square value (RMS) of the scanned surface profiles were recorded. Data were analysed by means of anova followed by Tukey's test. Scanning electron microscope observations revealed the presence of pitting and deep milling marks in all instruments. EDS analysis confirmed that both types of instruments were composed mainly of nickel and titanium, whilst AlphaKite had additional nitride. After multiple autoclave sterilization cycles, SEM examinations revealed an increase in surface alterations, and EDS values indicated changes in chemical surface composition in all instruments. Ra and RMS values of ProTaper significantly increased after 5 (P = 0.006) and 10 cycles (P = 0.002) with respect to the as-received instruments, whilst AlphaKite showed significant differences compared with the controls after 10 cycles (P = 0.03). Multiple autoclave sterilization cycles modified the surface topography and chemical composition of conventional and TiN -coated NiTi rotary instruments. © 2012 International Endodontic Journal.
Plotino, Gianluca; Costanzo, Alberto; Grande, Nicola M; Petrovic, Renata; Testarelli, Luca; Gambarini, Gianluca
2012-02-01
The purpose of this study was to evaluate the effect of autoclave sterilization on cyclic fatigue resistance of rotary endodontic instruments made of traditional and new nickel-titanium (NiTi) alloys. Four NiTi rotary endodontic instruments of the same size (tip diameter 0.40 mm and constant .04 taper) were selected: K3, Mtwo, Vortex, and K3 XF prototypes. Each group was then divided into 2 subgroups, unsterilized instruments and sterilized instruments. The sterilized instruments were subjected to 10 cycles of autoclave sterilization. Twelve files from each different subgroup were tested for cyclic fatigue resistance. Means and standard deviations of number of cycles to failure (NCF) and fragment length of the fractured tip were calculated for each group, and data were statistically analyzed (P < .05). Comparing the results between unsterilized and sterilized instruments for each type of file, differences were statistically significant (P < .05) only between sterilized and unsterilized K3XF files (762 versus 651 NCF). The other instruments did not show significant differences (P > .05) in the mean NCF as a result of sterilization cycles (K3, 424 versus 439 NCF; Mtwo, 409 versus 419 NCF; Vortex, 454 versus 480 NCF). Comparing the results among the different groups, K3 XF (either sterilized or not) showed a mean NCF significantly higher than all other files (P < .05). Repeated cycles of autoclave sterilization do not seem to influence the mechanical properties of NiTi endodontic instruments except for the K3 XF prototypes of rotary instruments that demonstrated a significant increase of cyclic fatigue resistance. Copyright © 2012 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Saha, Suparna Ganguly; Vijaywargiya, Neelam; Saxena, Divya; Saha, Mainak Kanti; Bharadwaj, Anuj; Dubey, Sandeep
2017-01-01
Introduction: To evaluate the incidence of microcrack formation canal preparation with two rotary nickel–titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. Materials and Methods: One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group (n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. Results: The highest incidence of microcracks were associated with the ProTaper Next group, 80% (P = 0.00), followed by the Mtwo group, 70% (P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% (P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups (P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups (P = 0.000) as well as the Mtwo and self-adjusting file groups (P = 0.000). Conclusion: All nickel–titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next. PMID:29386786
Failure of ProTaper rotary Ni-Ti instruments used by undergraduate students
Duran-Sindreu, Fernando; Morello-Castro, Sergio; Mercade-Bellido, Montserrat; Bueno-Martínez, Rufino; Roig-Cayón, Miguel
2012-01-01
Objective: To evaluate the effect of number of uses, angle and radius of curvature and type of instrument on the fracture of ProTaper rotary instruments when used by undergraduate students. Study Design: Three hundred and seventy-six molars, with a total of 1114 root canals, extracted were instrumented by undergraduate students using ProTaper instruments according to the manufacturer´s recommendations. When fracture occurred, data were collected concerning the number of uses, type of instrument, level of fracture, angle and radius of curvature. ANOVA test were used to determine the influence of type of instrument in the incidence of instrument fracture. Logistic regression model was used to determine the influence of number of uses, angle and radius of curvature in the incidence of instrument fracture. Significance was set at p< 0.05. Results: A total of 37 Ni-Ti rotary instruments fractured during the treatment. Fracture occurred in 9.84% (37/376) of the teeth treated and 3.32% of the canals prepared with Ni-Ti rotary instruments (37/1114). A decrease in the radius of curvature of the canal significantly increased the likelihood of fracture (p=0.0001). Instrument fracture significantly increased as the number of uses increased (p=0.0037). No significant differences were found between the 6 types of ProTaper instruments (p=0.8). A reduction in the angle of curvature did not produce a significant decrease in the incidence of instrument separation (p=0.08). Conclusions: The results of this study imply that instrument fracture is linked to radius of curvature and number of uses. Key words:Fracture, ProTaper ®, root canal preparation, undergraduate students. PMID:24558555
Tu, Ming-Gene; Chen, San-Yue; Huang, Heng-Li; Tsai, Chi-Cheng
2008-05-01
Preparing a continuous tapering conical shape and maintaining the original shape of a canal are obligatory in root canal preparation. The purpose of this study was to compare the shaping performance in simulated curved canal resin blocks of the same novice dental students using hand-prepared and engine-driven nickel-titanium (NiTi) rotary ProTaper instruments in an endodontic laboratory class. Twenty-three fourth-year dental students attending China Medical University Dental School prepared 46 simulated curved canals in resin blocks with two types of NiTi rotary systems: hand and motor ProTaper files. Composite images were prepared for estimation. Material removed, canal width and canal deviation were measured at five levels in the apical 4 mm of the simulated curved canals using AutoCAD 2004 software. Data were analyzed using Wilcoxon's rank-sum test. The hand ProTaper group cut significantly wider than the motor rotary ProTaper group in the outer wall, except for the apical 0 mm point. The total canal width was cut significantly larger in the hand group than in the motor group. There was no significant difference between the two groups in centering canal shape, except at the 3 mm level. These findings show that the novice students prepared the simulated curved canal that deviated more outwardly from apical 1 mm to 4 mm using the hand ProTaper. The ability to maintain the original curvature was better in the motor rotary ProTaper group than in the hand ProTaper group. Undergraduate students, if following the preparation sequence carefully, could successfully perform canal shaping by motor ProTaper files and achieve better root canal geometry than by using hand ProTaper files within the same teaching and practicing sessions.
Saha, Suparna Ganguly; Vijaywargiya, Neelam; Saxena, Divya; Saha, Mainak Kanti; Bharadwaj, Anuj; Dubey, Sandeep
2017-01-01
To evaluate the incidence of microcrack formation canal preparation with two rotary nickel-titanium systems Mtwo and ProTaper Next along with the self-adjusting file system. One hundred and twenty mandibular premolar teeth were selected. Standardized access cavities were prepared and the canals were manually prepared up to size 20 after coronal preflaring. The teeth were divided into three experimental groups and one control group ( n = 30). Group 1: The canals were prepared using Mtwo rotary files. Group 2: The canals were prepared with ProTaper Next files. Group 3: The canals were prepared with self-adjusting files. Group 4: The canals were unprepared and used as a control. The roots were sectioned horizontally 3, 6, and 9 mm from the apex and examined under a scanning electron microscope to check for the presence of microcracks. The Pearson's Chi-square test was applied. The highest incidence of microcracks were associated with the ProTaper Next group, 80% ( P = 0.00), followed by the Mtwo group, 70% ( P = 0.000), and the least number of microcracks was noted in the self-adjusting file group, 10% ( P = 0.068). No significant difference was found between the ProTaper Next and Mtwo groups ( P = 0.368) while a significant difference was observed between the ProTaper Next and self-adjusting file groups ( P = 0.000) as well as the Mtwo and self-adjusting file groups ( P = 0.000). All nickel-titanium rotary instrument systems were associated with microcracks. However, the self-adjusting file system had significantly fewer microcracks when compared with the Mtwo and ProTaper Next.
Effectiveness of rotary or manual techniques for removing a 6-year-old filling material.
Duarte, Marco Antônio Hungaro; Só, Marcus Vinícius Reis; Cimadon, Vanessa Buffon; Zucatto, Cristiane; Vier-Pelisser, Fabiana Vieira; Kuga, Milton Carlos
2010-01-01
The aim of this study was to evaluate the effectiveness of manual and rotary instrumentation techniques for removing root fillings after different storage times. Twenty-four canals from palatal roots of human maxillary molars were instrumented and filled with gutta-percha and zinc-oxide eugenol-based sealer (Endofill) , and were stored in saline for 6 years. Non-aged control specimens were treated in the same manner and stored for 1 week. All canals were retreated using hand files or ProTaper Universal NiTi rotary system. Radiographs were taken to determine the amount of remaining material in the canals. The roots were vertically split, the halves were examined with a clinical microscope and the obtained images were digitized. The images were evaluated with AutoCAD software and the percentage of residual material was calculated. Data were analyzed with two-way ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) between the manual and rotary techniques for filling material removal regardless the ageing effect on endodontic sealers. When only the age of the filling material was analyzed microscopically, non-aged fillings that remained on the middle third of the canals presented a higher percentage of material remaining (p<0.05) compared to the aged sealers and to the other thirds of the roots. The apical third showed a higher percentage of residual filling material in both radiographic and microscopic analysis when compared to the other root thirds. In conclusion, all canals presented residual filling material after endodontic retreatment procedures. Microscopic analysis was more effective than radiographs for detection of residual filling material.
2013-01-01
Background Efforts to improve the performance of rotary NiTi instruments by enhancing the properties of NiTi alloy, or their manufacturing processes rather than changes in instrument geometries have been reported. The aim of this study was to compare in-vitro the shaping ability of three different rotary nickel-titanium instruments produced by different manufacturing methods. Methods Thirty simulated root canals with a curvature of 35˚ in resin blocks were prepared with three different rotary NiTi systems: AK- AlphaKite (Gebr. Brasseler, Germany), GTX- GT® Series X (Dentsply, Germany) and TF- Twisted Files (SybronEndo, USA). The canals were prepared according to the manufacturers’ instructions. Pre- and post-instrumentation images were recorded and assessment of canal curvature modifications was carried out with an image analysis program (GSA, Germany). The preparation time and incidence of procedural errors were recorded. Instruments were evaluated under a microscope with 15 × magnifications (Carl Zeiss OPMI Pro Ergo, Germany) for signs of deformation. The Data were statistically analyzed using SPSS (Wilcoxon and Mann–Whitney U-tests, at a confidence interval of 95%). Results Less canal transportation was produced by TF apically, although the difference among the groups was not statistically significant. GTX removed the greatest amount of resin from the middle and coronal parts of the canal and the difference among the groups was statistically significant (p < 0.05). The shortest preparation time was registered with TF (444 s) and the longest with GTX (714 s), the difference among the groups was statistically significant (p < 0.05). During the preparation of the canals no instrument fractured. Eleven instruments of TF and one of AK were deformed. Conclusion Under the conditions of this study, all rotary NiTi instruments maintained the working length and prepared a well-shaped root canal. The least canal transportation was produced by AK. GTX displayed the greatest cutting efficiency. TF prepared the canals faster than the other two systems. PMID:24341354
Kaya, E; Elbay, M; Yiğit, D
2017-06-01
The Self-Adjusting File (SAF) system has been recommended for use in permanent teeth since it offers more conservative and effective root-canal preparation when compared to traditional rotary systems. However, no study had evaluated the usage of SAF in primary teeth. The aim of this study was to evaluate and compare the use of SAF, K file (manual instrumentation) and Profile (traditional rotary instrumentation) systems for primary-tooth root-canal preparation in terms of instrumentation time and amounts of dentin removed using micro-computed tomography (μCT) technology. Study Design: The study was conducted with 60 human primary mandibular second molar teeth divided into 3 groups according to instrumentation technique: Group I: SAF (n=20); Group II: K file (n=20); Group III; Profile (n=20). Teeth were embedded in acrylic blocks and scanned with a μCT scanner prior to instrumentation. All distal root canals were prepared up to size 30 for K file,.04/30 for Profile and 2 mm thickness, size 25 for SAF; instrumentation time was recorded for each tooth, and a second μCT scan was performed after instrumentation was complete. Amounts of dentin removed were measured using the three-dimensional images by calculating the difference in root-canal volume before and after preparation. Data was statistically analysed using the Kolmogorov-Smirnov and Kruskal-Wallis tests. Manual instrumentation (K file) resulted in significantly more dentin removal when compared to rotary instrumentation (Profile and SAF), while the SAF system generated significantly less dentin removal than both manual instrumentation (K file) and traditional rotary instrumentation (Profile) (p<.05). Instrumentation time was significantly greater with manual instrumentation when compared to rotary instrumentation (p<.05), whereas instrumentation time did not differ significantly between the Profile and SAF systems. Within the experimental conditions of the present study, the SAF seems as a useful system for root-canal instrumentation in primary molars because it removed less dentin than other systems, which is especially important for the relatively thin-walled canals of primary teeth, and because it involves less clinical time, which is particularly important in the treatment of paediatric patients.
Online optimal obstacle avoidance for rotary-wing autonomous unmanned aerial vehicles
NASA Astrophysics Data System (ADS)
Kang, Keeryun
This thesis presents an integrated framework for online obstacle avoidance of rotary-wing unmanned aerial vehicles (UAVs), which can provide UAVs an obstacle field navigation capability in a partially or completely unknown obstacle-rich environment. The framework is composed of a LIDAR interface, a local obstacle grid generation, a receding horizon (RH) trajectory optimizer, a global shortest path search algorithm, and a climb rate limit detection logic. The key feature of the framework is the use of an optimization-based trajectory generation in which the obstacle avoidance problem is formulated as a nonlinear trajectory optimization problem with state and input constraints over the finite range of the sensor. This local trajectory optimization is combined with a global path search algorithm which provides a useful initial guess to the nonlinear optimization solver. Optimization is the natural process of finding the best trajectory that is dynamically feasible, safe within the vehicle's flight envelope, and collision-free at the same time. The optimal trajectory is continuously updated in real time by the numerical optimization solver, Nonlinear Trajectory Generation (NTG), which is a direct solver based on the spline approximation of trajectory for dynamically flat systems. In fact, the overall approach of this thesis to finding the optimal trajectory is similar to the model predictive control (MPC) or the receding horizon control (RHC), except that this thesis followed a two-layer design; thus, the optimal solution works as a guidance command to be followed by the controller of the vehicle. The framework is implemented in a real-time simulation environment, the Georgia Tech UAV Simulation Tool (GUST), and integrated in the onboard software of the rotary-wing UAV test-bed at Georgia Tech. Initially, the 2D vertical avoidance capability of real obstacles was tested in flight. The flight test evaluations were extended to the benchmark tests for 3D avoidance capability over the virtual obstacles, and finally it was demonstrated on real obstacles located at the McKenna MOUT site in Fort Benning, Georgia. Simulations and flight test evaluations demonstrate the feasibility of the developed framework for UAV applications involving low-altitude flight in an urban area.
Hammad, Mohammad; Qualtrough, Alison; Silikas, Nick
2008-11-01
The aim of this study was to measure the remaining filling volume of different obturation materials from root-filled extracted teeth by using 2 removal techniques. Eighty single-rooted teeth were collected and decoronated, and the root canal was prepared by using the ProTaper nickel-titanium rotary files. The teeth were randomly allocated into 4 groups, and each group was obturated by using a different material. Group 1 was filled with gutta-percha and TubliSeal sealer, group 2 was filled with EndoRez points and EndoRez sealer, group 3 was filled with RealSeal points and RealSeal sealer, and Group 4 was filled with a gutta-percha point and GuttaFlow sealer. Teeth were scanned with a micro-computed tomography scan, and then root fillings were removed by using ProTaper retreatment files or hand K-files. Teeth were scanned again, and volume measurements were carried out with micro-computed tomography software. Statistical analysis showed significant differences between the 2 removal techniques for gutta-percha and for both techniques between gutta-percha and the other groups. The present study showed that all tested filling materials were not completely removed during retreatment by using hand or rotary files. Gutta-percha was more efficiently removed by using hand K-files.
Mechanical and Metallurgical Properties of Various Nickel-Titanium Rotary Instruments
Shim, Kyu-Sang; Oh, Soram; Kim, Yu-Chan; Jee, Kwang-Koo
2017-01-01
The aim of this study was to investigate the effect of thermomechanical treatment on mechanical and metallurgical properties of nickel-titanium (NiTi) rotary instruments. Eight kinds of NiTi rotary instruments with sizes of ISO #25 were selected: ProFile, K3, and One Shape for the conventional alloy; ProTaper NEXT, Reciproc, and WaveOne for the M-wire alloy; HyFlex CM for the controlled memory- (CM-) wire; and TF for the R-phase alloy. Torsional fracture and cyclic fatigue fracture tests were performed. Products underwent a differential scanning calorimetry (DSC) analysis. The CM-wire and R-phase groups had the lowest elastic modulus, followed by the M-wire group. The maximum torque of the M-wire instrument was comparable to that of a conventional instrument, while those of the CM-wire and R-phase instruments were lower. The angular displacement at failure (ADF) for the CM-wire and R-phase instruments was higher than that of conventional instruments, and ADF of the M-wire instruments was lower. The cyclic fatigue resistance of the thermomechanically treated NiTi instruments was higher. DSC plots revealed that NiTi instruments made with the conventional alloy were primarily composed of austenite at room temperature; stable martensite and R-phase were found in thermomechanically treated instruments. PMID:29318149
Gambarini, Gianluca; Grande, Nicola Maria; Plotino, Gianluca; Somma, Francesco; Garala, Manish; De Luca, Massimo; Testarelli, Luca
2008-08-01
The aim of the present study was to investigate whether cyclic fatigue resistance is increased for nickel-titanium instruments manufactured by using new processes. This was evaluated by comparing instruments produced by using the twisted method (TF; SybronEndo, Orange, CA) and those using the M-wire alloy (GTX; Dentsply Tulsa-Dental Specialties, Tulsa, OK) with instruments produced by a traditional NiTi grinding process (K3, SybronEndo). Tests were performed with a specific cyclic fatigue device that evaluated cycles to failure of rotary instruments inside curved artificial canals. Results indicated that size 06-25 TF instruments showed a significant increase (p < 0.05) in the mean number of cycles to failure when compared with size 06-25 K3 files. Size 06-20 K3 instruments showed no significant increase (p > 0.05) in the mean number of cycles to failure when compared with size 06-20 GT series X instruments. The new manufacturing process produced nickel-titanium rotary files (TF) significantly more resistant to fatigue than instruments produced with the traditional NiTi grinding process. Instruments produced with M-wire (GTX) were not found to be more resistant to fatigue than instruments produced with the traditional NiTi grinding process.
Limongi, Orlando; de Albuquerque, Diana Santana; Baratto Filho, Flares; Vanni, José Roberto; de Oliveira, Elias P Motcy; Barletta, Fernando Branco
2007-01-01
This in vitro study compared, using computed tomography (CT), the amount of dentin removed from root canal walls by manual and mechanical rotary instrumentation techniques. Forty mandibular incisors with dental crown and a single canal were selected. The teeth were randomly assigned to two groups, according to the technique used for root canal preparation: Group I - manual instrumentation with stainless steel files; Group II - mechanical instrumentation with RaCe rotary nickel-titanium instruments. In each tooth, root dentin thickness of the buccal, lingual, mesial and distal surfaces in the apical, middle and cervical thirds of the canal was measured (in mm) using a multislice CT scanner (Siemens Emotion, Duo). Data were stored in the SPSS v. 11.5 and SigmaPlot 2001 v. 7.101 softwares. After crown opening, working length was determined, root canals were instrumented and new CT scans were taken for assessment of root dentin thickness. Pre- and post-instrumentation data were compared and analyzed statistically by ANOVA and Tukey's post-hoc test for significant differences (p=0.05). Based on the findings of this study, it may be concluded that regarding dentin removal from root canal walls during instrumentation, neither of the techniques can be considered more effective than the other.
Development of a Meso-Scale Fiberoptic Rotation Sensor for a Torsion Actuator.
Sheng, Jun; Desai, Jaydev P
2018-01-01
This paper presents the development of a meso-scale fiberoptic rotation sensor for a shape memory alloy (SMA) torsion actuator for neurosurgical applications. Within the sensor, a rotary head with a reflecting surface is capable of modulating the light intensity collected by optical fibers when the rotary head is coupled to the torsion actuator. The mechanism of light intensity modulation is modeled, followed by experimental model verification. Meanwhile, working performances for different rotary head designs, optical fibers, and fabrication materials are compared. After the calibration of the fiberoptic rotation sensor, the sensor is capable of precisely measuring rotary motion and controlling the SMA torsion actuator with feedback control.
ROTARY FUEL INJECTION PUMP WEAR TESTING USING A 30 %/ 70% ATJ/F-24 FUEL BLEND
2017-09-30
30/70 ATJ/F-24 with 24-ppm CI/LI Fuel at 77 ºC ............................................... 49 Figure 28. Pump SN:17200043 Transfer Pump Blade ...Pump SN:17200043 Transfer Pump Blade Edges with 1000-Hours Testing with 30/70 ATJ/F-24 with 24-ppm CI/LI Fuel at 77 ºC...50 Figure 30. Pump SN:17200043 Transfer Pump Blade Sides before Testing with 30/70 ATJ/F-24 with 24-ppm CI/LI Fuel at 77 ºC
1994-01-20
Category 2 - Investigation/Debug Required ..................................... 11 Table 3-1 Field Test Report Status/Corrective Action...in Table 3-1 in section 3.1. The Field Test Reports and SP/CR’s are listed below for the two categories: Table 3.0-1. Category 1 - LADS PMO Direction...symbology, consisting Wing Aircraft of the laser code A - H plus the four digit data field shall be displayed for 10 seconds, after which time only
Structure of the vacuolar H+-ATPase rotary motor reveals new mechanistic insights.
Rawson, Shaun; Phillips, Clair; Huss, Markus; Tiburcy, Felix; Wieczorek, Helmut; Trinick, John; Harrison, Michael A; Muench, Stephen P
2015-03-03
Vacuolar H(+)-ATPases are multisubunit complexes that operate with rotary mechanics and are essential for membrane proton transport throughout eukaryotes. Here we report a ∼ 1 nm resolution reconstruction of a V-ATPase in a different conformational state from that previously reported for a lower-resolution yeast model. The stator network of the V-ATPase (and by implication that of other rotary ATPases) does not change conformation in different catalytic states, and hence must be relatively rigid. We also demonstrate that a conserved bearing in the catalytic domain is electrostatic, contributing to the extraordinarily high efficiency of rotary ATPases. Analysis of the rotor axle/membrane pump interface suggests how rotary ATPases accommodate different c ring stoichiometries while maintaining high efficiency. The model provides evidence for a half channel in the proton pump, supporting theoretical models of ion translocation. Our refined model therefore provides new insights into the structure and mechanics of the V-ATPases. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Abu-Tahun, Ibrahim; El-Ma'aita, Ahmad; Khraisat, Ameen
2016-08-01
The aim of this study was to report the satisfaction of fifth year undergraduate students on the clinical use of rotary endodontic preparation compared with stainless steel standard technique and to evaluate the impact of rotary nickel-titanium instruments on undergraduate teaching. This study was carried out by the fifth year undergraduate students attending peer review sessions as a part of their training program using a questionnaire to assess their satisfaction with these two techniques. The overall results indicated a statistically significant satisfaction of the undergraduate students with the use of the nickel-titanium system (P < 0.001) compared to stainless steel standard technique. Under the conditions of this study, the results showed a positive acceptance and consensus among novice dental students regarding the use of ProTaper rotary files and the need for undergraduate teaching of rotary nickel-titanium systems in Jordan. © 2015 Australian Society of Endodontology Inc.
Dietle, Lannie L; Schroeder, John E; Kalsi, Manmohan S; Alvarez, Patricio D
2013-08-13
A rotary shaft sealing assembly in which a first fluid is partitioned from a second fluid in a housing assembly having a rotary shaft located at least partially within. In one embodiment a lip seal is lubricated and flushed with a pressure-generating seal ring preferably having an angled diverting feature. The pressure-generating seal ring and a hydrodynamic seal may be used to define a lubricant-filled region with each of the seals having hydrodynamic inlets facing the lubricant-filled region. Another aspect of the sealing assembly is having a seal to contain pressurized lubricant while withstanding high rotary speeds. Another rotary shaft sealing assembly embodiment includes a lubricant supply providing a lubricant at an elevated pressure to a region between a lip seal and a hydrodynamic seal with a flow control regulating the flow of lubricant past the lip seal. The hydrodynamic seal may include an energizer element having a modulus of elasticity greater than the modulus of elasticity of a sealing lip of the hydrodynamic seal.
Dietle, Lannie L.; Schroeder, John E.; Kalsi, Manmohan S.; Alvarez, Patricio D.
2010-09-21
A rotary shaft sealing assembly in which a first fluid is partitioned from a second fluid in a housing assembly having a rotary shaft located at least partially within. In one embodiment a lip seal is lubricated and flushed with a pressure-generating seal ring preferably having an angled diverting feature. The pressure-generating seal ring and a hydrodynamic seal may be used to define a lubricant-filled region with each of the seals having hydrodynamic inlets facing the lubricant-filled region. Another aspect of the sealing assembly is having a seal to contain pressurized lubricant while withstanding high rotary speeds. Another rotary shaft sealing assembly embodiment includes a lubricant supply providing a lubricant at an elevated pressure to a region between a lip seal and a hydrodynamic seal with a flow control regulating the flow of lubricant past the lip seal. The hydrodynamic seal may include an energizer element having a modulus of elasticity greater than the modulus of elasticity of a sealing lip of the hydrodynamic seal.
Catalysis-Enhancement via Rotary Fluctuation of F1-ATPase
Watanabe, Rikiya; Hayashi, Kumiko; Ueno, Hiroshi; Noji, Hiroyuki
2013-01-01
Protein conformational fluctuations modulate the catalytic powers of enzymes. The frequency of conformational fluctuations may modulate the catalytic rate at individual reaction steps. In this study, we modulated the rotary fluctuation frequency of F1-ATPase (F1) by attaching probes with different viscous drag coefficients at the rotary shaft of F1. Individual rotation pauses of F1 between rotary steps correspond to the waiting state of a certain elementary reaction step of ATP hydrolysis. This allows us to investigate the impact of the frequency modulation of the rotary fluctuation on the rate of the individual reaction steps by measuring the duration of rotation pauses. Although phosphate release was significantly decelerated, the ATP-binding and hydrolysis steps were less sensitive or insensitive to the viscous drag coefficient of the probe. Brownian dynamics simulation based on a model similar to the Sumi-Marcus theory reproduced the experimental results, providing a theoretical framework for the role of rotational fluctuation in F1 rate enhancement. PMID:24268150
Schirrmeister, Jörg F; Strohl, Christian; Altenburger, Markus J; Wrbas, Karl-Thomas; Hellwig, Elmar
2006-06-01
To compare the shaping ability and safety of engine-driven FlexMaster, GT Rotary, ProFile, ProTaper, and RaCe rotary instrumentation and Hedström hand instrumentation in simulated root canals. One hundred fifty simulated colored root canals with a curvature of 20 degrees and a radius of 10 mm were randomly distributed among 6 groups of 25 specimens each. After preparation to apical size 30 the area of remaining color on the canal wall indicating unprepared areas was measured in mm2 using image analyzer software. Specimens treated with RaCe left least areas of remaining color compared to all other groups (P < .001), followed by ProTaper. Preparation with ProFile left behind the highest amount of unprepared areas. The ProFile group revealed significantly more remaining color than ProTaper, GT Rotary, and FlexMaster (P < .05). Four FlexMaster files separated. RaCe rotary files were safe and more effective compared to the other instruments.
Advanced liquid-cooled, turbocharged and intercooled stratified charge rotary engines for aircraft
NASA Technical Reports Server (NTRS)
Mount, Robert E.; Bartel, John; Hady, William F.
1987-01-01
Developments concerning stratified-charge rotary (SCR) engines over the past 10 years are reviewed. Aircraft engines being developed using SCR technology are shown and described, and the ability of such technology to meet general aviation engine needs is considered. Production timing and availability of SCR technology for the development of aviation rotary engines are discussed, and continuing efforts toward improving this technology, including NASA efforts, are described.
A Short Study of Large Rotary Forged Cylinders
1979-06-01
ESR Steel Hollow ESR Steel Rotary Forge Vacuum Degassed Steel 20. ABSTRACT (Continue on reverse aide It necessary and identity by block number...treatment rging Line was used to produce steel for the Advanced ocram. Cylinders were rotary forged from cast hollow ESR ssed steel . Anomalies in the data...prompted a more detailed The results are presented. Satisfactory properties were cuum degassed steel . However, the very light forging th the very
NASA Technical Reports Server (NTRS)
Jones, C.
1978-01-01
The development of the rotary engine as a viable power plant capable of wide application is reviewed. Research results on the stratified charge engine with direct chamber injection are included. Emission control, reduced fuel consumption, and low noise level are among the factors discussed in terms of using the rotary engine in general aviation aircraft.
Geometric analysis of maxillary first premolar prepared by two nickel-titanium rotary instruments.
Al-Sudani, Dina; Almalki, Majed; Al-Shahrani, Saad; Ahlquist, Michael
2014-03-01
The present study was conducted with the aim of evaluating and comparing the shaping ability of two Nickel-titanium rotary instruments, with two disparate design features, on root canal geometry of extracted human maxillary first premolars using microcomputed tomography. Twenty four bifurcated maxillary first premolars were divided into two groups and embedded in a rubber-based impression material. Both groups were submitted to micro-computed tomography before and after canal preparation (buccal and palatal) with either ProFile Vortex or Revo-S rotary instruments. Images were reconstructed and cross-sections corresponding to a distance 1, 2, 3, 4, 5, 6, and 7 mm from the anatomical apex were selected for canal transportation analysis. Volume changes were also measured. The degree and direction of canal transportation were non-significant for both instruments. Statistically significant differences were observed only between levels in the buccal canal in both groups. There was no significant difference between the two rotary systems in regards to the volume of dentin removed. Our findings showed that ProFile Vortex and Revo-S instruments respected the original root canal anatomy and behaved similarly. ProFile Vortex rotary systems produced with innovative process were concluded to shape the upper maxillary premolar by leading minimal canal transportation, similar to Revo-S, rotary systems produced from traditional process.
Rôças, I N; Lima, K C; Siqueira, J F
2013-07-01
To compare the antibacterial efficacy of two instrumentation techniques, one using hand nickel-titanium (NiTi) instruments and the other using rotary NiTi instruments, in root canals of teeth with apical periodontitis. Root canals from single-rooted teeth were instrumented using either hand NiTi instruments in the alternated rotation motion technique or rotary BioRaCe instruments. The irrigant used in both groups was 2.5% NaOCl. DNA extracts from samples taken before and after instrumentation were subjected to quantitative analysis by real-time polymerase chain reaction (qPCR). Qualitative analysis was also performed using presence/absence data from culture and qPCR assays. Bacteria were detected in all S1 samples by both methods. In culture analysis, 45% and 35% of the canals were still positive for bacterial presence after hand and rotary NiTi instrumentation, respectively (P > 0.05). Rotary NiTi instrumentation resulted in significantly fewer qPCR-positive cases (60%) than hand NiTi instrumentation (95%) (P = 0.01). Intergroup comparison of quantitative data showed no significant difference between the two techniques. There was no significant difference in bacterial reduction in infected canals after instrumentation using hand or rotary NiTi instruments. In terms of incidence of positive results for bacteria, culture also showed no significant differences between the groups, but the rotary NiTi instrumentation resulted in more negative results in the more sensitive qPCR analysis. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Explosively Joining Dissimilar Metal Tubes.
1979-11-01
specimens were tested in axial tension-tension fatigue in a Satec high cycle fatigue test machine at 30 Hz. The applied max stress for each test was...BACK CHIP A3 ROTARY FILE ,S AR .STO P9 WIRE BRUSH y es IDENTIFY {STEEL STAMP) N INSPECT ICA) YES GRIND WEtD [LEID k R IJ CA/S. BASE METAL PPEPARATION...Type: Dog bone Test Equipment: Satec SF-1U-1099 Specimen Max. Static Dynamic F a i1 u r e Width Thickness i(No.) Stress Stress Stress(KS0 (KSI) (KSI
The rotary gallstone lithotrite to aid gallbladder extraction in laparoscopic cholecystectomy.
Sackier, J M; Hunter, J G; Paz-Partlow, M; Cuschieri, A
1992-01-01
During laparoscopic cholecystectomy, a large stone burden may cause difficulty when extracting the gallbladder through the abdominal wall. Currently, the alternatives available to the surgeon include increasing the incision, removing stones singly, or utilizing complex fragmentation techniques like the pulsed dye laser. We have employed an electromechanical rotary gallstone lithotrite (RGL) to fragment stones to an aspiratable size. Initially, cholesterol spheres were pulverized in a latex balloon to demonstrate the efficacy of the device. Then, human gallstones were placed in the balloon and reduced to fragments less than or equal to 1 mm from initial sizes of 4-24 mm. Human stones were then inserted in ex vivo porcine gallbladders in a controlled experiment and treated with the device. Ten out of 12 tests were completed within 30 s; one test required 49 s and one 105 s to achieve complete fragmentation. Blinded histological evaluation demonstrated that tissue abrasion caused by use of the device would not interfere with the diagnosis of unsuspected malignancy. Clinical trials have now commenced under the auspices of the hospital ethical committee.
Coordinate measuring machine test standard apparatus and method
Bieg, L.F.
1994-08-30
A coordinate measuring machine test standard apparatus and method are disclosed which includes a rotary spindle having an upper phase plate and an axis of rotation, a kinematic ball mount attached to the phase plate concentric with the axis of rotation of the phase plate, a groove mounted at the circumference of the phase plate, and an arm assembly which rests in the groove. The arm assembly has a small sphere at one end and a large sphere at the other end. The small sphere may be a coordinate measuring machine probe tip and may have variable diameters. The large sphere is secured in the kinematic ball mount and the arm is held in the groove. The kinematic ball mount includes at least three mounting spheres and the groove is an angular locating groove including at least two locking spheres. The arm may have a hollow inner core and an outer layer. The rotary spindle may be a ratio reducer. The device is used to evaluate the measuring performance of a coordinate measuring machine for periodic recertification, including 2 and 3 dimensional accuracy, squareness, straightness, and angular accuracy. 5 figs.
Coordinate measuring machine test standard apparatus and method
Bieg, Lothar F.
1994-08-30
A coordinate measuring machine test standard apparatus and method which iudes a rotary spindle having an upper phase plate and an axis of rotation, a kinematic ball mount attached to the phase plate concentric with the axis of rotation of the phase plate, a groove mounted at the circumference of the phase plate, and an arm assembly which rests in the groove. The arm assembly has a small sphere at one end and a large sphere at the other end. The small sphere may be a coordinate measuring machine probe tip and may have variable diameters. The large sphere is secured in the kinematic ball mount and the arm is held in the groove. The kinematic ball mount includes at least three mounting spheres and the groove is an angular locating groove including at least two locking spheres. The arm may have a hollow inner core and an outer layer. The rotary spindle may be a ratio reducer. The device is used to evaluate the measuring performance of a coordinate measuring machine for periodic recertification, including 2 and 3 dimensional accuracy, squareness, straightness, and angular accuracy.
The NASA aircraft icing research program
NASA Technical Reports Server (NTRS)
Shaw, Robert J.; Reinmann, John J.
1990-01-01
The objective of the NASA aircraft icing research program is to develop and make available to industry icing technology to support the needs and requirements for all-weather aircraft designs. Research is being done for both fixed wing and rotary wing applications. The NASA program emphasizes technology development in two areas, advanced ice protection concepts and icing simulation. Reviewed here are the computer code development/validation, icing wind tunnel testing, and icing flight testing efforts.
New Ultra-High Sensitivity, Absolute, Linear, and Rotary Encoders
NASA Technical Reports Server (NTRS)
Leviton, Douglas B.
1998-01-01
Several new types of absolute optical encoders of both rotary and linear function are discussed. The means for encoding are complete departures from conventional optical encoders and offer advantages of compact form, immunity to damage-induced dropouts of position information, and about an order of magnitude higher sensitivity over what is commercially available. Rotary versions have sensitivity from 0.02 arcseconds down to 0.003 arcsecond while linear models have sensitivity of 10 nm.
Shape-Memory Wires Switch Rotary Actuator
NASA Technical Reports Server (NTRS)
Brudnicki, Myron J.
1992-01-01
Thermomechanical rotary actuator based on shape-memory property of alloy composed of equal parts of titanium and nickel. If alloy stretched while below transition temperature, it reverts to original length when heated above transition temperature. Two capstans on same shaft wrapped with shape-memory wires. As one wire heated, it contracts and stretches opposite wire. Wires heated in alternation so they switch shaft between two extreme angular positions; "on" and "off" positions of rotary valve.
Optical Energy Transfer and Conversion System
NASA Technical Reports Server (NTRS)
Hogan, Bartholomew P. (Inventor); Stone, William C. (Inventor)
2015-01-01
An optical power transfer system comprising a fiber spooler, a fiber optic rotary joint mechanically connected to the fiber spooler, and an electrical power extraction subsystem connected to the fiber optic rotary joint with an optical waveguide. Optical energy is generated at and transferred from a base station through fiber wrapped around the spooler, through the rotary joint, and ultimately to the power extraction system at a remote mobility platform for conversion to another form of energy.
Application of a magnetic fluid seal to rotary blood pumps
NASA Astrophysics Data System (ADS)
Mitamura, Y.; Arioka, S.; Sakota, D.; Sekine, K.; Azegami, M.
2008-05-01
A magnetic fluid seal enables mechanical contact-free rotation of a shaft without frictional heat and material wear and hence has excellent durability. However, the durability of a magnetic fluid seal decreases in liquid. The life of a seal applied to a rotary blood pump is not known. We have developed a magnetic fluid seal that has a shield mechanism minimizing the influence of the rotary pump on the magnetic fluid. The developed magnetic fluid seal worked for over 286 days in a continuous flow condition, for 24 days (on-going) in a pulsatile flow condition and for 24 h (electively terminated) in blood flow. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.
Application of a magnetic fluid seal to rotary blood pumps.
Mitamura, Y; Arioka, S; Sakota, D; Sekine, K; Azegami, M
2008-05-21
A magnetic fluid seal enables mechanical contact-free rotation of a shaft without frictional heat and material wear and hence has excellent durability. However, the durability of a magnetic fluid seal decreases in liquid. The life of a seal applied to a rotary blood pump is not known. We have developed a magnetic fluid seal that has a shield mechanism minimizing the influence of the rotary pump on the magnetic fluid. The developed magnetic fluid seal worked for over 286 days in a continuous flow condition, for 24 days (on-going) in a pulsatile flow condition and for 24 h (electively terminated) in blood flow. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.
Performance of rotary kiln reactor for the elephant grass pyrolysis.
De Conto, D; Silvestre, W P; Baldasso, C; Godinho, M
2016-10-01
The influence of process conditions (rotary speed/temperature) on the performance of a rotary kiln reactor for non-catalytic pyrolysis of a perennial grass (elephant grass) was investigated. The product yields, the production of non-condensable gases as well as the biochar properties were evaluated. The maximum H2 yield was close to that observed for catalytic pyrolysis processes, while the bio-oil yield was higher than reported for pyrolysis of other biomass in rotary kiln reactors. A H2/CO ratio suitable for Fischer-Tropsch synthesis (FTS) was obtained. The biochars presented an alkaline pH (above 10) and interesting contents of nutrients, as well as low electrical conductivity, indicating a high potential as soil amendment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Capar, Ismail Davut; Kaval, Mehmet Emin; Ertas, Hüseyin; Sen, Bilge Hakan
2015-04-01
This study compared the cyclic fatigue resistance of current nickel-titanium rotary path-finding instruments. Five types of nickel-titanium rotary pathfinding instruments were used in steel canals with a 90° curvature and a curvature radius of 3 mm (n = 10) and 5 mm (n = 10). The cyclic fatigue of the following instruments was tested at 4 mm from the tip: PathFile (#16 and a .02 taper; Dentsply Maillefer, Ballaigues, Switzerland), G-File (#12 and a .03 taper; Micro-Mega, Besançon Cedex, France), Scout Race (#15 and a .02 taper; FKG Dentaire, La Chaux-de-Fonds, Switzerland), HyFlex GPF (#15 and a .02 taper; Coltene-Whaledent, Allstetten, Switzerland), and ProGlider (#16 with a mean taper of .04125 and a .02 at the first 4 mm from the tip, Dentsply Maillefer). The length of the fractured parts was measured, and the number of cycles to fracture (NCF) was calculated. The data were statistically analyzed using Kruskal-Wallis and Mann-Whitney tests (α = .05). After Bonferroni correction, the new P value was set as .005. The difference in the cyclic fatigue of all the files at both curvatures was statistically significant (P values from .0035 to less than .0001). The ranking of the instruments from the highest to the lowest NCF was as follows: HyFlex GPF, G files, ProGlider, PathFile, and Scout Race. The length of the fractured part of the instruments was similar in all the groups (P > .05). All the tested instruments had a lower NCF at a curvature radius of 3 mm when compared with a curvature radius of 5 mm (P < .0001). Within the limitations of this study, the cyclic fatigue resistance of the HyFlex GPF instrument was the highest, and the curvature radius had a significant effect on the fatigue resistance. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Pawar, Ajinkya M.; Pawar, Mansing; Kfir, Anda; Thakur, Bhagyashree; Mutha, Pooja; Banga, Kulwinder Singh
2017-01-01
Aim: The aim of this study was to test the effect of new protocol of glide path preparation by 20/0.04 rotary file on apical extrusion of debris when instrumenting fine curved mesial canals in mandibular molars with Self-adjusting File (SAF) and compare it to a glide path prepared by 20/0.02 hand K-file and rotary OneShape (OS) and reciprocating WaveOne (WO) file instrumentation. Materials and Methods: Sixty mandibular molars with curved mesial roots were selected and randomly divided into three groups (n = 20) for instrumentation. In two groups, glide path was prepared using 20/0.02 K-file for instrumentation by OS (size 25/0.06 taper) and WO (size 25/0.08 taper) files; in the remaining group, 20/0.04 rotary file was used for glide path preparation and instrumented by SAF (1.5 mm). The debris extruded during instrumentation was collected in preweighed Eppendorf tubes and stored in an incubator at 70°C for 5 days. Tubes containing the dry extruded debris were then weighed. One-way analysis of variance (ANOVA) was applied to the weights obtained, followed by Tukey's post hoc test for multiple comparison. Results: The mean debris (g) extruded apically was 0.000651 ± 0.000291, 0.000823 ± 0.000319, and 0.000473 ± 0.000238 for Group 1 (20/0.02 + OS), Group 2 (20/0.02 + WO), and Group 3 (20/0.04 + SAF), respectively. The groups exhibited a significant difference (P < 0.01; ANOVA). Group 3 resulted in least debris extrusion compared to Groups 1 and 2 (P < 0.01; Tukey's post hoc test). Conclusion: Glide path prepared to size 20/0.04 and SAF 1.5 mm instrumentation produce less debris in curved mesial canals of mandibular molars, compared to glide path established by 20/0.02 and instrumentation by OS and WO files. PMID:28855758
Basheer Ahamed, Shadir Bughari; Vanajassun, Purushothaman Pranav; Rajkumar, Kothandaraman; Mahalaxmi, Sekar
2018-04-01
Single cross-sectional nickel-titanium (NiTi) rotary instruments during continuous rotations are subjected to constant and variable stresses depending on the canal anatomy. This study was intended to create 2 new experimental, theoretic single-file designs with combinations of triple U (TU), triangle (TR), and convex triangle (CT) cross sections and to compare their bending stresses in simulated root canals with a single cross-sectional instrument using finite element analysis. A 3-dimensional model of the simulated root canal with 45° curvature and NiTi files with 5 cross-sectional designs were created using Pro/ENGINEER Wildfire 4.0 software (PTC Inc, Needham, MA) and ANSYS software (version 17; ANSYS, Inc, Canonsburg, PA) for finite element analysis. The NiTi files of 3 groups had single cross-sectional shapes of CT, TR, and TU designs, and 2 experimental groups had a CT, TR, and TU (CTU) design and a TU, TR, and CT (UTC) design. The file was rotated in simulated root canals to analyze the bending stress, and the von Mises stress value for every file was recorded in MPa. Statistical analysis was performed using the Kruskal-Wallis test and the Bonferroni-adjusted Mann-Whitney test for multiple pair-wise comparison with a P value <.05 (95 %). The maximum bending stress of the rotary file was observed in the apical third of the CT design, whereas comparatively less stress was recorded in the CTU design. The TU and TR designs showed a similar stress pattern at the curvature, whereas the UTC design showed greater stress in the apical and middle thirds of the file in curved canals. All the file designs showed a statistically significant difference. The CTU designed instruments showed the least bending stress on a 45° angulated simulated root canal when compared with all the other tested designs. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Treatment of phosphate-containing oily wastewater by coagulation and microfiltration.
Zhang, Jin; Sun, Yu-xin; Huang, Zhi-feng; Liu, Xing-qin; Meng, Guang-yao
2006-01-01
The oily wastewater generated from pretreatment unit of electrocoating industry contains oils, phosphate, organic solvents, and surfactants. In order to improve the removal efficiencies of phosphate and oils, to mitigate the membrane fouling, coagulation for ceramic membrane microfiltration of oily wastewater was performed. The results of filtration tests show that the membrane fouling decreased and the permeate flux and quality increased with coagulation as pretreatment. At the coagulant Ca (OH)2 dosage of 900 mg/L, the removal efficiency of phosphate was increased from 46.4% without coagulation to 99.6%; the removal of COD and oils were 97.0% and 99.8%, respectively. And the permeate flux was about 70% greater than that when Ca(OH)2 was not used. The permeate obtained from coagulation and microfiltration can be reused as make-up water, and the recommended operation conditions for pilot and industrial application are transmembrane pressure of 0.10 MPa and cross-flow velocity of 5 m/s. The comparison results show that 0.2 microm ZrO2 microfilter with coagulation could be used to perform the filtration rather than conventional ultrafilter, with very substantial gain in flux and removal efficiency of phosphate.
Auto-Gopher: A Wire-Line Rotary-Hammer Ultrasonic Drill
NASA Technical Reports Server (NTRS)
Badescu, Mircea; Sherrit, Stewart; Bao, Xiaogi; Bar-Cohen, Yoseph; Chen, Beck
2011-01-01
Developing technologies that would enable NASA to sample rock, soil, and ice by coring, drilling or abrading at a significant depth is of great importance for a large number of in-situ exploration missions as well as for earth applications. Proven techniques to sample Mars subsurface will be critical for future NASA astrobiology missions that will search for records of past and present life on the planet, as well as, the search for water and other resources. A deep corer, called Auto-Gopher, is currently being developed as a joint effort of the JPL's NDEAA laboratory and Honeybee Robotics Corp. The Auto-Gopher is a wire-line rotary-hammer drill that combines rock breaking by hammering using an ultrasonic actuator and cuttings removal by rotating a fluted bit. The hammering mechanism is based on the Ultrasonic/Sonic Drill/Corer (USDC) that has been developed as an adaptable tool for many of drilling and coring applications. The USDC uses an intermediate free-flying mass to transform the high frequency vibrations of the horn tip into a sonic hammering of a drill bit. The USDC concept was used in a previous task to develop an Ultrasonic/Sonic Ice Gopher. The lessons learned from testing the ice gopher were implemented into the design of the Auto-Gopher by inducing a rotary motion onto the fluted coring bit. A wire-line version of such a system would allow penetration of significant depth without a large increase in mass. A laboratory version of the corer was developed in the NDEAA lab to determine the design and drive parameters of the integrated system. The design configuration lab version of the design and fabrication and preliminary testing results are presented in this paper
Dahlström, L; Molander, A; Reit, C
2015-02-01
The aim of the study was to test the hypothesis that a further education programme relating to nickel-titanium rotary instrumentation (NTRI), with the concurrent activation of social/professional networks amongst all general dental practitioners (GDPs) in a public dental service in Sweden, would increase the adoption rate and improve root-filling quality. To activate the networks, the GDPs at the 25 clinics elected training coaches from amongst themselves. The coaches were educated by a specialist and were then free to organise and conduct the training of the local GDPs. However, collective hands-on training and discussions were mandatory. Lectures were held by an endodontist. The rate of adoption and root-filling quality was evaluated just before and 6 months after the education. Statistical tests were performed with chi-square using a 95% confidence interval. Nickel-titanium rotary instrumentation was adopted by 88%. Excellent root fillings (score 1) increased from 45% to 59% (P = 0.003). The rate of poor-quality root fillings (score 4 and score 5) was not affected. The quality ratio (score 1/score 5) increased from 5.36 (118/22) to 9.5 (133/14). Eleven dentists (17%) at nine different clinics produced 49% of the poor-quality root fillings (score 4 and score 5). Seventy-three per cent of these dentists stated that they had adopted NTRI. The introduction of NTRI will increase the adoption rate and the frequency of good-quality root fillings. However, it will not overcome the problems associated with dentists producing a low-quality level, even if a local professional network is activated. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Comparin, Daniel; Moreira, Edson Jorge Lima; Souza, Erick M; De-Deus, Gustavo; Arias, Ana; Silva, Emmanuel João Nogueira Leal
2017-07-01
The aim of this randomized clinical trial was to evaluate the influence of rotary or reciprocating retreatment techniques on the incidence, intensity, duration of postoperative pain, and medication intake. After power analysis calculations, 65 patients who needed endodontic retreatment were randomly assigned to 1 of 2 groups according to the instrumentation system used: Mtwo (VDW, Munich, Germany) or Reciproc (VDW). Retreatments were performed in a single visit by an endodontic specialist. Participants were asked to rate the incidence and intensity of the postoperative pain on a verbal rating scale 24, 48, and 72 hours after treatment. Patients were also asked to record the number of prescribed analgesic medication tablets (ibuprofen 400 mg) taken. A logistic regression analysis was used to assess both the incidence and duration of pain. Differences in the intensity of pain were analyzed using the ordinal (linear) chi-square test, and the Mann-Whitney U test was used to assess differences in the intake of analgesic medication between groups. No statistically significant difference was found among the 2 groups in relation to postoperative pain or analgesic medication intake at the 3 time points assessed (P > .05). Multivariate analysis showed a significantly higher incidence of pain after 24 hours when preoperative pain was present and a significantly longer duration of pain for men than women independently of the retreatment technique used. The reciprocating system and the continuous rotary system were found to be equivalent regarding the incidence, intensity, duration of postoperative pain, and intake of analgesic medication. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Tokita, Daisuke; Ebihara, Arata; Miyara, Kana; Okiji, Takashi
2017-08-01
This study examined the dynamic fracture behavior of nickel-titanium rotary instruments in torsional or cyclic loading at continuous or reciprocating rotation by means of high-speed digital video imaging. The ProFile instruments (size 30, 0.06 taper; Dentsply Maillefer, Ballaigues, Switzerland) were categorized into 4 groups (n = 7 in each group) as follows: torsional/continuous (TC), torsional/reciprocating (TR), cyclic/continuous (CC), and cyclic/reciprocating (CR). Torsional loading was performed by rotating the instruments by holding the tip with a vise. For cyclic loading, a custom-made device with a 38° curvature was used. Dynamic fracture behavior was observed with a high-speed camera. The time to fracture was recorded, and the fractured surface was examined with scanning electron microscopy. The TC group initially exhibited necking of the file followed by the development of an initial crack line. The TR group demonstrated opening and closing of a crack according to its rotation in the cutting and noncutting directions, respectively. The CC group separated without any detectable signs of deformation. In the CR group, initial crack formation was recognized in 5 of 7 samples. The reciprocating rotation exhibited a longer time to fracture in both torsional and cyclic fatigue testing (P < .05). The scanning electron microscopic images showed a severely deformed surface in the TR group. The dynamic fracture behavior of NiTi rotary instruments, as visualized with high-speed digital video imaging, varied between the different modes of rotation and different fatigue testing. Reciprocating rotation induced a slower crack propagation and conferred higher fatigue resistance than continuous rotation in both torsional and cyclic loads. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Vaudt, J; Bitter, K; Neumann, K; Kielbassa, A M
2009-01-01
To investigate instrumentation time, working safety and the shaping ability of two rotary nickel-titanium (NiTi) systems (Alpha System and ProTaper Universal) in comparison to stainless steel hand instruments. A total of 45 mesial root canals of extracted human mandibular molars were selected. On the basis of the degree of curvature the matched teeth were allocated randomly into three groups of 15 teeth each. In group 1 root canals were prepared to size 30 using a standardized manual preparation technique; in group 2 and 3 rotary NiTi instruments were used following the manufacturers' instructions. Instrumentation time and procedural errors were recorded. With the aid of pre- and postoperative radiographs, apical straightening of the canal curvature was determined. Photographs of the coronal, middle and apical cross-sections of the pre- and postoperative canals were taken, and superimposed using a standard software. Based on these composite images the portion of uninstrumented canal walls was evaluated. Active instrumentation time of the Alpha System was significantly reduced compared with ProTaper Universal and hand instrumentation (P < 0.05; anova). No instrument fractures occurred in any of the groups. The Alpha System revealed significantly less apical straightening compared with the other instruments (P < 0.05; Mann-Whitney U test). In the apical cross-sections Alpha System resulted in significantly less uninstrumented canal walls compared with stainless steel files (P < 0.05; chi-squared test). Despite the demonstrated differences between the systems, an apical straightening effect could not be prevented; areas of uninstrumented root canal wall were left in all regions using the various systems.