Sample records for rotated test case

  1. Comparison of shoulder internal rotation test with the elbow flexion test in the diagnosis of cubital tunnel syndrome.

    PubMed

    Ochi, Kensuke; Horiuchi, Yukio; Tanabe, Aya; Morita, Kozo; Takeda, Kentaro; Ninomiya, Ken

    2011-05-01

    To compare the shoulder internal rotation test-a new, provocative test-with the elbow flexion test in the diagnosis of cubital tunnel syndrome (CubTS). Twenty-five patients with CubTS were examined before and after surgery with 10 seconds each of the elbow flexion and shoulder internal rotation tests. Fifty-four asymptomatic individuals and 14 neuropathy patients with a diagnosis other than CubTS were also examined as control cases. For the shoulder internal rotation test, the patient's upper extremity was kept at 90° abduction, maximum internal rotation, and 10° flexion at the shoulder, with 90° elbow flexion and neutral position of the forearm and wrist, with finger extension. Test results were considered positive if any slight symptom attributable to CubTS occurred within 10 seconds. Extraneural pressure inside the cubital tunnel was intraoperatively measured with the positions of both the elbow flexion and shoulder internal rotation tests, in 15 of the CubTS cases. Statistical analyses were performed using Student's t-test with a confidence level of 95%. The preoperative sensitivity in CubTS cases was 80% in the 10-second shoulder internal rotation test and 36% in the 10-second elbow flexion test, and these differences were significant. None of the control cases had positive results in either test. All the CubTS cases improved with surgery; after surgery, neither test provoked symptoms in any surgical patient. The extraneural pressure increased in both provocative positions with no significant difference. Positive results for the 10-second shoulder internal rotation test were more sensitive than that for the elbow flexion test of the same duration and seemed specific to CubTS. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. Modeling the dissipation rate in rotating turbulent flows

    NASA Technical Reports Server (NTRS)

    Speziale, Charles G.; Raj, Rishi; Gatski, Thomas B.

    1990-01-01

    A variety of modifications to the modeled dissipation rate transport equation that have been proposed during the past two decades to account for rotational strains are examined. The models are subjected to two crucial test cases: the decay of isotropic turbulence in a rotating frame and homogeneous shear flow in a rotating frame. It is demonstrated that these modifications do not yield substantially improved predictions for these two test cases and in many instances give rise to unphysical behavior. An alternative proposal, based on the use of the tensor dissipation rate, is made for the development of improved models.

  3. Jet Engine Bird Ingestion Simulations: Comparison of Rotating to Non-Rotating Fan Blades

    NASA Technical Reports Server (NTRS)

    Howard, Samuel A.; Hammer, Jeremiah; Carney, Kelly S.; Pereira, J. Michael

    2013-01-01

    Bird strike events in commercial airliners are a fairly common occurrence. According to data collected by the US Department of Agriculture, over 80,000 bird strikes were reported in the period 1990-2007 in the US alone [1]. As a result, bird ingestion is an important factor in aero engine design and FAA certification. When it comes to bird impacts on engine fan blades, the FAA requires full-scale bird ingestion tests on an engine running at full speed to pass certification requirements. These rotating tests are complex and very expensive. To reduce development costs associated with new materials for fan blades, it is desirable to develop more cost effective testing procedures than full-scale rotating engine tests for material evaluation. An impact test on a non-rotating single blade that captures most of the salient physics of the rotating test would go a long way towards enabling large numbers of evaluative material screening tests. NASA Glenn Research Center has been working to identify a static blade test procedure that would be effective at reproducing similar results as seen in rotating tests. The current effort compares analytical simulations of a bird strike on various nonrotating blades to a bird strike simulation on a rotating blade as a baseline case. Several different concepts for simulating the rotating loads on a non-rotating blade were analyzed with little success in duplicating the deformation results seen in the rotating case. The rotating blade behaves as if it were stiffer than the non-rotating blade resulting in less plastic deformation from a given bird impact. The key factor limiting the success of the non-rotating blade simulations is thought to be the effect of gyroscopics. Prior to this effort, it was anticipated the difficulty would be in matching the pre-stress in the blade due to centrifugal forces Additional work is needed to verify this assertion, and to determine if a static test procedure can simulate the gyroscopic effects in a suitable manner. This paper describes the various non-rotating concepts analyzed, and demonstrates the effect believed to be gyroscopic in nature on the results.

  4. Jet Engine Bird Ingestion Simulations: Comparison of Rotating to Non-Rotating Fan Blades

    NASA Technical Reports Server (NTRS)

    Howard, Samuel A.; Hammer, Jeremiah T.; Carney, Kelly S.; Pereira, J. Michael

    2013-01-01

    Bird strike events in commercial airliners are a fairly common occurrence. According to data collected by the US Department of Agriculture, over 80,000 bird strikes were reported in the period 1990 to 2007 in the US alone (Ref. 1). As a result, bird ingestion is an important factor in aero engine design and FAA certification. When it comes to bird impacts on engine fan blades, the FAA requires full-scale bird ingestion tests on an engine running at full speed to pass certification requirements. These rotating tests are complex and very expensive. To reduce development costs associated with new materials for fan blades, it is desirable to develop more cost effective testing procedures than full-scale rotating engine tests for material evaluation. An impact test on a nonrotating single blade that captures most of the salient physics of the rotating test would go a long way towards enabling large numbers of evaluative material screening tests. NASA Glenn Research Center has been working to identify a static blade test procedure that would be effective at reproducing similar results as seen in rotating tests. The current effort compares analytical simulations of a bird strike on various non-rotating blades to a bird strike simulation on a rotating blade as a baseline case. Several different concepts for simulating the rotating loads on a non-rotating blade were analyzed with little success in duplicating the deformation results seen in the rotating case. The rotating blade behaves as if it were stiffer than the non-rotating blade resulting in less plastic deformation from a given bird impact. The key factor limiting the success of the non-rotating blade simulations is thought to be the effect of gyroscopics. Prior to this effort, it was anticipated the difficulty would be in matching the prestress in the blade due to centrifugal forces Additional work is needed to verify this assertion, and to determine if a static test procedure can simulate the gyroscopic effects in a suitable manner. This paper describes the various non-rotating concepts analyzed, and demonstrates the effect believed to be gyroscopic in nature on the results

  5. Comparison of 2 resident learning tools-interactive screen-based simulated case scenarios versus problem-based learning discussions: a prospective quasi-crossover cohort study.

    PubMed

    Rajan, Shobana; Khanna, Ashish; Argalious, Maged; Kimatian, Stephen J; Mascha, Edward J; Makarova, Natalya; Nada, Eman M; Elsharkawy, Hesham; Firoozbakhsh, Farhad; Avitsian, Rafi

    2016-02-01

    Simulation-based learning is emerging as an alternative educational tool in this era of a relative shortfall of teaching anesthesiologists. The objective of the study is to assess whether screen-based (interactive computer simulated) case scenarios are more effective than problem-based learning discussions (PBLDs) in improving test scores 4 and 8 weeks after these interventions in anesthesia residents during their first neuroanesthesia rotation. Prospective, nonblinded quasi-crossover study. Cleveland Clinic. Anesthesiology residents. Two case scenarios were delivered from the Anesoft software as screen-based sessions, and parallel scripts were developed for 2 PBLDs. Each resident underwent both types of training sessions, starting with the PBLD session, and the 2 cases were alternated each month (ie, in 1 month, the screen-based intervention used case 1 and the PBLD used case 2, and vice versa for the next month). Test scores before the rotation (baseline), immediately after the rotation (4 weeks after the start of the rotation), and 8 weeks after the start of rotation were collected on each topic from each resident. The effect of training method on improvement in test scores was assessed using a linear mixed-effects model. Compared to the departmental standard of PBLD, the simulation method did not improve either the 4- or 8-week mean test scores (P = .41 and P = .40 for training method effect on 4- and 8-week scores, respectively). Resident satisfaction with the simulation module on a 5-point Likert scale showed subjective evidence of a positive impact on resident education. Screen-based simulators were not more effective than PBLD for education during the neuroanesthesia rotation in anesthesia residency. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Rotational molding of pultruded profiles reinforced polyethylene

    NASA Astrophysics Data System (ADS)

    Greco, Antonio; Maffezzoli, Alfonso; Romano, Giorgio

    2014-05-01

    The aim of this paper is the production of fiber reinforced LLDPE components by rotational molding. To this purpose, a process upgrade was developed, for the incorporation of pultruded tapes in the rotational molding cycle. Pultruded tapes, made of 50% by weight of glass fibers dispersed in a high density polyethylene(HDPE) matrix, were glued on the internal surface of a cubic mold, and rotational molding process was run using the same processing conditions used for conventional LLDPE processing. During processing, melting of LLDPE powders and of HDPE allowed to incorporate the tapes inside rotational molded LLDPE. The glass fiber reinforced prototypes were characterized in terms of mechanical properties. Plate bending tests were performed on the square faces extracted from the rotational molded product. The rotational molding products were also subjected to internal hydrostatic pressure tests up to 10 bar. In any case, no failure of the cubic samples was observed. In both cases, it was found that addition of a single pultruded strips, which corresponds to addition of about 0.6% by weight of glass fibers, involved an increase of the stiffness of the faces by about 25%.

  7. A Vision-Based Dynamic Rotational Angle Measurement System for Large Civil Structures

    PubMed Central

    Lee, Jong-Jae; Ho, Hoai-Nam; Lee, Jong-Han

    2012-01-01

    In this paper, we propose a vision-based rotational angle measurement system for large-scale civil structures. Despite the fact that during the last decade several rotation angle measurement systems were introduced, they however often required complex and expensive equipment. Therefore, alternative effective solutions with high resolution are in great demand. The proposed system consists of commercial PCs, commercial camcorders, low-cost frame grabbers, and a wireless LAN router. The calculation of rotation angle is obtained by using image processing techniques with pre-measured calibration parameters. Several laboratory tests were conducted to verify the performance of the proposed system. Compared with the commercial rotation angle measurement, the results of the system showed very good agreement with an error of less than 1.0% in all test cases. Furthermore, several tests were conducted on the five-story modal testing tower with a hybrid mass damper to experimentally verify the feasibility of the proposed system. PMID:22969348

  8. A vision-based dynamic rotational angle measurement system for large civil structures.

    PubMed

    Lee, Jong-Jae; Ho, Hoai-Nam; Lee, Jong-Han

    2012-01-01

    In this paper, we propose a vision-based rotational angle measurement system for large-scale civil structures. Despite the fact that during the last decade several rotation angle measurement systems were introduced, they however often required complex and expensive equipment. Therefore, alternative effective solutions with high resolution are in great demand. The proposed system consists of commercial PCs, commercial camcorders, low-cost frame grabbers, and a wireless LAN router. The calculation of rotation angle is obtained by using image processing techniques with pre-measured calibration parameters. Several laboratory tests were conducted to verify the performance of the proposed system. Compared with the commercial rotation angle measurement, the results of the system showed very good agreement with an error of less than 1.0% in all test cases. Furthermore, several tests were conducted on the five-story modal testing tower with a hybrid mass damper to experimentally verify the feasibility of the proposed system.

  9. The effect of prevalence of disease on performance of residents and fellows during training for interpreting DBT in a test-train-test observer study

    NASA Astrophysics Data System (ADS)

    Hakim, Christiane M.; Chang Sen, Lauren; Degnan, Andrew; Delic, Joseph; Pai, Sarah; Sagreiya, Hersh; Sparrow, Mark; Thomas, Ernestine; Yannes, Michael; Gur, David

    2017-03-01

    There are no data on the effect of disease prevalence during training for interpreting digital breast tomosynthesis (DBT) based screening examinations on the performance of residents and fellows. We assessed the performance of six residents (four after one breast imaging rotation and two after two rotations) and two fellows in breast imaging when interpreting DBT screening examinations in a multi-case, mode balanced, test- train-test retrospective reader study (127 training and 160 testing cases). Half were trained with feedback of verified truth after reviewing each case with low prevalence of disease (13/127) and half with high prevalence (52/128). The pre- and post- training dataset was the same. Performance measures were compared (sensitivity, specificity and AUC). Readers trained with the low prevalence set decreased the overall recall rate of non-cancer cases (FPF from 0.21 to 0.13, <0.001), and of cases with known malignancies (TPF from 0.70 to 0.61, p=0.004, due primarily to one clearly outlier reader). Readers trained with the high prevalence increased the overall recall rate (albeit, not statistically significant) of non-cancer cases (FPF from 0.16 to 0.18, p=0.07), and a borderline significant increase of cancer cases (TPF from 0.61 to 0.66, p=0.04). Fellows post six months of specialty training in each group had no significant changes in sensitivity, specificity, or AUC after training (smallest p>0.07). Both residents with two rotations experience had significant changes in sensitivity and specificity (highest p<0.028), but not in AUC. Early training with low disease prevalence of "what not to recall" should be included during training.

  10. An Investigation into the Challenges In-Service Student Teachers Encounter in Transformational Geometry, "Reflection and Rotation". The Case of Mufulira College of Education

    ERIC Educational Resources Information Center

    Kambilombilo, Dennis; Sakala, Whyson

    2015-01-01

    The study was conducted to investigate the challenges in-service mathematics student teachers face in transformational geometry; reflection and rotation. The Van Hiele Theory of levels of Thought was used as the theoretical framework for this study. A case study was undertaken using a written test. The research was carried on second and third…

  11. Study of tethered satellite active attitude control

    NASA Technical Reports Server (NTRS)

    Colombo, G.

    1982-01-01

    Existing software was adapted for the study of tethered subsatellite rotational dynamics, an analytic solution for a stable configuration of a tethered subsatellite was developed, the analytic and numerical integrator (computer) solutions for this "test case' was compared in a two mass tether model program (DUMBEL), the existing multiple mass tether model (SKYHOOK) was modified to include subsatellite rotational dynamics, the analytic "test case,' was verified, and the use of the SKYHOOK rotational dynamics capability with a computer run showing the effect of a single off axis thruster on the behavior of the subsatellite was demonstrated. Subroutines for specific attitude control systems are developed and applied to the study of the behavior of the tethered subsatellite under realistic on orbit conditions. The effect of all tether "inputs,' including pendular oscillations, air drag, and electrodynamic interactions, on the dynamic behavior of the tether are included.

  12. Testing neoclassical and turbulent effects on poloidal rotation in the core of DIII-D

    DOE PAGES

    Chrystal, Colin; Burrell, Keith H.; Grierson, Brian A.; ...

    2014-07-09

    Experimental tests of ion poloidal rotation theories have been performed on DIII-D using a novel impurity poloidal rotation diagnostic. These tests show significant disagreements with theoretical predictions in various conditions, including L-mode plasmas with internal transport barriers (ITB), H-mode plasmas, and QH-mode plasmas. The theories tested include standard neoclassical theory, turbulence driven Reynolds stress, and fast-ion friction on the thermal ions. Poloidal rotation is observed to spin up at the formation of an ITB and makes a significant contribution to the measurement of themore » $$\\vec{E}$$ × $$\\vec{B}$$ shear that forms the ITB. In ITB cases, neoclassical theory agrees quantitatively with the experimental measurements only in the steep gradient region. Significant quantitative disagreement with neoclassical predictions is seen in the cores of ITB, QH-, and H-mode plasmas, demonstrating that neoclassical theory is an incomplete description of poloidal rotation. The addition of turbulence driven Reynolds stress does not remedy this disagreement; linear stability calculations and Doppler backscattering measurements show that disagreement increases as turbulence levels decline. Furthermore, the effect of fast-ion friction, by itself, does not lead to improved agreement; in QH-mode plasmas, neoclassical predictions are closest to experimental results in plasmas with the largest fast ion friction. Finally, predictions from a new model that combines all three effects show somewhat better agreement in the H-mode case, but discrepancies well outside the experimental error bars remain.« less

  13. Impact and Estimation of Balance Coordinate System Rotations and Translations in Wind-Tunnel Testing

    NASA Technical Reports Server (NTRS)

    Toro, Kenneth G.; Parker, Peter A.

    2017-01-01

    Discrepancies between the model and balance coordinate systems lead to biases in the aerodynamic measurements during wind-tunnel testing. The reference coordinate system relative to the calibration coordinate system at which the forces and moments are resolved is crucial to the overall accuracy of force measurements. This paper discusses sources of discrepancies and estimates of coordinate system rotation and translation due to machining and assembly differences. A methodology for numerically estimating the coordinate system biases will be discussed and developed. Two case studies are presented using this methodology to estimate the model alignment. Examples span from angle measurement system shifts on the calibration system to discrepancies in actual wind-tunnel data. The results from these case-studies will help aerodynamic researchers and force balance engineers to better the understand and identify potential differences in calibration systems due to coordinate system rotation and translation.

  14. Constraining torsion with Gravity Probe B

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mao Yi; Guth, Alan H.; Cabi, Serkan

    2007-11-15

    It is well-entrenched folklore that all torsion gravity theories predict observationally negligible torsion in the solar system, since torsion (if it exists) couples only to the intrinsic spin of elementary particles, not to rotational angular momentum. We argue that this assumption has a logical loophole which can and should be tested experimentally, and consider nonstandard torsion theories in which torsion can be generated by macroscopic rotating objects. In the spirit of action=reaction, if a rotating mass like a planet can generate torsion, then a gyroscope would be expected to feel torsion. An experiment with a gyroscope (without nuclear spin) suchmore » as Gravity Probe B (GPB) can test theories where this is the case. Using symmetry arguments, we show that to lowest order, any torsion field around a uniformly rotating spherical mass is determined by seven dimensionless parameters. These parameters effectively generalize the parametrized post-Newtonian formalism and provide a concrete framework for further testing Einstein's general theory of relativity (GR). We construct a parametrized Lagrangian that includes both standard torsion-free GR and Hayashi-Shirafuji maximal torsion gravity as special cases. We demonstrate that classic solar system tests rule out the latter and constrain two observable parameters. We show that Gravity Probe B is an ideal experiment for further constraining nonstandard torsion theories, and work out the most general torsion-induced precession of its gyroscope in terms of our torsion parameters.« less

  15. Metasurfaced Reverberation Chamber.

    PubMed

    Sun, Hengyi; Li, Zhuo; Gu, Changqing; Xu, Qian; Chen, Xinlei; Sun, Yunhe; Lu, Shengchen; Martin, Ferran

    2018-01-25

    The concept of metasurfaced reverberation chamber (RC) is introduced in this paper. It is shown that by coating the chamber wall with a rotating 1-bit random coding metasurface, it is possible to enlarge the test zone of the RC while maintaining the field uniformity as good as that in a traditional RC with mechanical stirrers. A 1-bit random coding diffusion metasurface is designed to obtain all-direction backscattering under normal incidence. Three specific cases are studied for comparisons, including a (traditional) mechanical stirrer RC, a mechanical stirrer RC with a fixed diffusion metasurface, and a RC with a rotating diffusion metasurface. Simulation results show that the compact rotating diffusion metasurface can act as a stirrer with good stirring efficiency. By using such rotating diffusion metasurface, the test region of the RC can be greatly extended.

  16. Equilibrium configurations of a charged fluid around a Kerr black hole

    NASA Astrophysics Data System (ADS)

    Trova, Audrey; Schroven, Kris; Hackmann, Eva; Karas, Vladimír; Kovář, Jiří; Slaný, Petr

    2018-05-01

    Equilibrium configurations of electrically charged perfect fluid surrounding a central rotating black hole endowed with a test electric charge and embedded in a large-scale asymptotically uniform magnetic field are presented. Following our previous studies considering the central black hole to be nonrotating, we show that in the rotating case conditions for the configurations existence change according to the spin of the black hole. We focus our attention on the charged fluid in rigid rotation, which can form toroidal configurations centered in the equatorial plane or the ones hovering above the black hole, along the symmetry axis. We conclude that a nonzero value of spin changes the existence conditions and the morphology of the solutions significantly. In the case of fast rotation, the morphology of the structures is close to an oblate shape.

  17. A web-based simulation of a longitudinal clinic used in a 4-week ambulatory rotation: a cohort study

    PubMed Central

    Wong, Rene WG; Lochnan, Heather A

    2009-01-01

    Background Residency training takes place primarily on inpatient wards. In the absence of a resident continuity clinic, internal medicine residents rely on block rotations to learn about continuity of care. Alternate methods to introduce continuity of care are needed. Methods A web-based tool, Continuity of Care Online Simulations (COCOS), was designed for use in a one-month, postgraduate clinical rotation in endocrinology. It is an interactive tool that simulates the continuing care of any patient with a chronic endocrine disease. Twenty-three residents in internal medicine participated in a study to investigate the effects of using COCOS during a clinical rotation in endocrinology on pre-post knowledge test scores and self-assessment of confidence. Results Compared to residents who did the rotation alone, residents who used COCOS during the rotation had significantly higher improvements in test scores (% increase in pre-post test scores +21.6 [standard deviation, SD, 8.0] vs. +5.9 [SD 6.8]; p < .001). Test score improvements were most pronounced for less commonly seen conditions. There were no significant differences in changes in confidence. Residents rated COCOS very highly, recommending its use as a standard part of the rotation and throughout residency. Conclusion A stand-alone web-based tool can be incorporated into an existing clinical rotation to help residents learn about continuity of care. It has the most potential to teach residents about topics that are less commonly seen during a clinical rotation. The adaptable, web-based format allows the creation of cases for most chronic medical conditions. PMID:19187554

  18. A novel torsional exciter for modal vibration testing of large rotating machinery

    NASA Astrophysics Data System (ADS)

    Sihler, Christof

    2006-10-01

    A novel exciter for applying a dynamic torsional force to a rotating structure is presented in this paper. It has been developed at IPP in order to perform vibration tests with shaft assemblies of large flywheel generators (synchronous machines). The electromagnetic exciter (shaker) needs no fixture to the rotating shaft because the torque is applied by means of the stator winding of an electrical machine. Therefore, the exciter can most easily be applied in cases where a three-phase electrical machine (a motor or generator) is part of the shaft assembly. The oscillating power for the shaker is generated in a separate current-controlled DC circuit with an inductor acting as a buffer storage of magnetic energy. An AC component with adjustable frequency is superimposed on the inductor current in order to generate pulsating torques acting on the rotating shaft with the desired waveform and frequency. Since this torsional exciter does not require an external power source, can easily be installed (without contact to the rotating structure) and provides dynamic torsional forces which are sufficient for multi-megawatt applications, it is best suited for on-site tests of large rotating machinery.

  19. Optimal control of lift/drag ratios on a rotating cylinder

    NASA Technical Reports Server (NTRS)

    Ou, Yuh-Roung; Burns, John A.

    1992-01-01

    We present the numerical solution to a problem of maximizing the lift to drag ratio by rotating a circular cylinder in a two-dimensional viscous incompressible flow. This problem is viewed as a test case for the newly developing theoretical and computational methods for control of fluid dynamic systems. We show that the time averaged lift to drag ratio for a fixed finite-time interval achieves its maximum value at an optimal rotation rate that depends on the time interval.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zaorsky, Nicholas G.; Malatesta, Theresa M.; Den, Robert B.

    Purpose: Few medical students are given proper clinical training in oncology, much less radiation oncology. We attempted to assess the value of adding a radiation oncology clinical rotation to the medical school curriculum. Methods and Materials: In July 2010, Jefferson Medical College began to offer a 3-week radiation oncology rotation as an elective course for third-year medical students during the core surgical clerkship. During 2010 to 2012, 52 medical students chose to enroll in this rotation. The rotation included outpatient clinics, inpatient consults, didactic sessions, and case-based presentations by the students. Tests of students' knowledge of radiation oncology were administeredmore » anonymously before and after the rotation to evaluate the educational effectiveness of the rotation. Students and radiation oncology faculty were given surveys to assess feedback about the rotation. Results: The students' prerotation test scores had an average of 64% (95% confidence interval [CI], 61-66%). The postrotation test scores improved to an average of 82% (95% CI, 80-83%; 18% absolute improvement). In examination question analysis, scores improved in clinical oncology from 63% to 79%, in radiobiology from 70% to 77%, and in medical physics from 62% to 88%. Improvements in all sections but radiobiology were statistically significant. Students rated the usefulness of the rotation as 8.1 (scale 1-9; 95% CI, 7.3-9.0), their understanding of radiation oncology as a result of the rotation as 8.8 (95% CI, 8.5-9.1), and their recommendation of the rotation to a classmate as 8.2 (95% CI, 7.6-9.0). Conclusions: Integrating a radiation oncology clinical rotation into the medical school curriculum improves student knowledge of radiation oncology, including aspects of clinical oncology, radiobiology, and medical physics. The rotation is appreciated by both students and faculty.« less

  1. Activity characteristics and movement patterns in people with and people without low back pain who participate in rotation-related sports

    PubMed Central

    Chimenti, Ruth L.; Scholtes, Sara A.

    2013-01-01

    Many risk factors have been identified as contributing to the development or persistence of low back pain (LBP). However, the juxtaposition of both high and low levels of physical activity being associated with LBP reflects the complexity of the relationship between a risk factor and LBP. Moreover, not everyone with an identified risk factor, such as a movement pattern of increased lumbopelvic rotation, has LBP. Objective The purpose of this study was to examine differences in activity level and movement patterns between people with and people without chronic or recurrent LBP who participate in rotation-related sports. Design Case Case-control study. Setting University laboratory environment. Participants 52 people with chronic or recurrent LBP and 25 people without LBP who all play a rotation-related sport. Main Outcome Measures Participants completed self-report measures including the Baecke Habitual Activity Questionnaire and a questionnaire on rotation-related sports. A 3-dimensional motion-capture system was used to collect movement-pattern variables during 2 lower-limb-movement tests. Results Compared with people without LBP, people with LBP reported a greater difference between the sport subscore and an average work and leisure composite subscore on the Baecke Habitual Activity Questionnaire (F = 6.55, P = .01). There were no differences between groups in either rotation-related-sport participation or movement-pattern variables demonstrated during 2 lower-limb movement tests (P > .05 for all comparisons). Conclusions People with and people without LBP who regularly play a rotation-related sport differed in the amount and nature of activity participation but not in movement pattern variables. An imbalance between level of activity during sport and daily functions may contribute to the development or persistence of LBP in people who play a rotation-related sport. PMID:23295458

  2. Rapidly rotating neutron stars with a massive scalar field—structure and universal relations

    NASA Astrophysics Data System (ADS)

    Doneva, Daniela D.; Yazadjiev, Stoytcho S.

    2016-11-01

    We construct rapidly rotating neutron star models in scalar-tensor theories with a massive scalar field. The fact that the scalar field has nonzero mass leads to very interesting results since the allowed range of values of the coupling parameters is significantly broadened. Deviations from pure general relativity can be very large for values of the parameters that are in agreement with the observations. We found that the rapid rotation can magnify the differences several times compared to the static case. The universal relations between the normalized moment of inertia and quadrupole moment are also investigated both for the slowly and rapidly rotating cases. The results show that these relations are still EOS independent up to a large extend and the deviations from pure general relativity can be large. This places the massive scalar-tensor theories amongst the few alternative theories of gravity that can be tested via the universal I-Love-Q relations.

  3. Solar system constraints on planetary Coriolis-type effects induced by rotation of distant masses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iorio, Lorenzo, E-mail: lorenzo.iorio@libero.it

    We phenomenologically put local constraints on the rotation of distant masses by using the planets of the solar system. First, we analytically compute the orbital secular precessions induced on the motion of a test particle about a massive primary by a Coriolis-like force, treated as a small perturbation, in the case of a constant angular velocity vector Ψ directed along a generic direction in space. The semimajor axis a and the eccentricity e of the test particle do not secularly change, contrary to the inclination I, the longitude of the ascending node Ω, the longitude of the pericenter varpi andmore » the mean anomaly M. Then, we compare our prediction for (dot varpi) with the corrections Δdot varpi to the usual perihelion precessions of the inner planets recently estimated by fitting long data sets with different versions of the EPM ephemerides. We obtain as preliminary upper bounds |Ψ{sub z}| ≤ 0.0006−0.013 arcsec cty{sup −1}, |Ψ{sub x}| ≤ 0.1−2.7 arcsec cty{sup −1}, |Ψ{sub y}| ≤ 0.3−2.3 arcsec cty{sup −1}. Interpreted in terms of models of space-time involving cosmic rotation, our results are able to yield constraints on cosmological parameters like the cosmological constant Λ and the Hubble parameter H{sub 0} not too far from their values determined with cosmological observations and, in some cases, several orders of magnitude better than the constraints usually obtained so far from space-time models not involving rotation. In the case of the rotation of the solar system throughout the Galaxy, occurring clockwise about the North Galactic Pole, our results for Ψ{sub z} are in disagreement with the expected value of it at more than 3−σ level. Modeling the Oort cloud as an Einstein-Thirring slowly rotating massive shell inducing Coriolis-type forces inside yields unphysical results for its putative rotation.« less

  4. Testing the recovery of stellar rotation signals from Kepler light curves using a blind hare-and-hounds exercise

    NASA Astrophysics Data System (ADS)

    Aigrain, S.; Llama, J.; Ceillier, T.; Chagas, M. L. das; Davenport, J. R. A.; García, R. A.; Hay, K. L.; Lanza, A. F.; McQuillan, A.; Mazeh, T.; de Medeiros, J. R.; Nielsen, M. B.; Reinhold, T.

    2015-07-01

    We present the results of a blind exercise to test the recoverability of stellar rotation and differential rotation in Kepler light curves. The simulated light curves lasted 1000 d and included activity cycles, Sun-like butterfly patterns, differential rotation and spot evolution. The range of rotation periods, activity levels and spot lifetime were chosen to be representative of the Kepler data of solar-like stars. Of the 1000 simulated light curves, 770 were injected into actual quiescent Kepler light curves to simulate Kepler noise. The test also included five 1000-d segments of the Sun's total irradiance variations at different points in the Sun's activity cycle. Five teams took part in the blind exercise, plus two teams who participated after the content of the light curves had been released. The methods used included Lomb-Scargle periodograms and variants thereof, autocorrelation function and wavelet-based analyses, plus spot modelling to search for differential rotation. The results show that the `overall' period is well recovered for stars exhibiting low and moderate activity levels. Most teams reported values within 10 per cent of the true value in 70 per cent of the cases. There was, however, little correlation between the reported and simulated values of the differential rotation shear, suggesting that differential rotation studies based on full-disc light curves alone need to be treated with caution, at least for solar-type stars. The simulated light curves and associated parameters are available online for the community to test their own methods.

  5. Cyclic fatigue of ProFile rotary instruments after prolonged clinical use.

    PubMed

    Gambarini, G

    2001-07-01

    The purpose of the present study was to evaluate resistance to cyclic fatigue of new and used ProFile Ni-Ti rotary instruments. Used instruments were operated in 10 clinical cases using passive instrumentation and a crown-down preparation technique. Cyclic fatigue testing of new and used engine-driven instruments was then performed with a specific device which allowed the instruments to rotate freely inside a stainless steel artificial canal, whilst maintaining conditions close to the clinical situation. Instruments were rotated until fracture occurred and time to fracture was visually recorded with a chronometer. A significant reduction of rotation time to breakage (life span) was noted between new and used instruments. In all sizes new instruments were significantly more resistant than used ones (two-sample t-test, P < 0.01). No instrument underwent intracanal failure during clinical use. Prolonged clinical use of Ni-Ti engine-driven instruments significantly reduced their cyclic fatigue resistance. Nevertheless, each rotary instrument was successfully operated in up to 10 clinical cases without any intracanal failure.

  6. Aircraft Digital Input Controlled Hydraulic Actuation and Control System.

    DTIC Science & Technology

    1981-03-01

    the individual pistons in each motor which act against its rotating swash plate to drive...single piston during each of two equal rotations of the output shaft. In the high-displacement case, the swash plate is assumed to move through an angle...for their assistance in conducting laboratory tests of the digital electrohydraulic actuation system. Vii TABLE OF CONTENTS Section Page I

  7. Genome-wide association study for rotator cuff tears identifies two significant single-nucleotide polymorphisms.

    PubMed

    Tashjian, Robert Z; Granger, Erin K; Farnham, James M; Cannon-Albright, Lisa A; Teerlink, Craig C

    2016-02-01

    The precise etiology of rotator cuff disease is unknown, but prior evidence suggests a role for genetic factors. Limited data exist identifying specific genes associated with rotator cuff tearing. The purpose of this study was to identify specific genes or genetic variants associated with rotator cuff tearing by a genome-wide association study with an independent set of rotator cuff tear cases. A set of 311 full-thickness rotator cuff tear cases genotyped on the Illumina 5M single-nucleotide polymorphism (SNP) platform were used in a genome-wide association study with 2641 genetically matched white population controls available from the Illumina iControls database. Tests of association were performed with GEMMA software at 257,558 SNPs that compose the intersection of Illumina SNP platforms and that passed general quality control metrics. SNPs were considered significant if P < 1.94 × 10(-7) (Bonferroni correction: 0.05/257,558). Tests of association revealed 2 significantly associated SNPs, one occurring in SAP30BP (rs820218; P = 3.8E-9) on chromosome 17q25 and another occurring in SASH1 (rs12527089; P = 1.9E-7) on chromosome 6q24. This study represents the first attempt to identify genetic factors influencing rotator cuff tearing by a genome-wide association study using a dense/complete set of SNPs. Two SNPs were significantly associated with rotator cuff tearing, residing in SAP30BP on chromosome 17 and SASH1 on chromosome 6. Both genes are associated with the cellular process of apoptosis. Identification of potential genes or genetic variants associated with rotator cuff tearing may help in identifying individuals at risk for the development of rotator cuff tearing. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  8. Laboratory tests of catastrophic disruption of rotating bodies

    NASA Astrophysics Data System (ADS)

    Morris, A. J. W.; Burchell, M. J.

    2017-11-01

    The results of catastrophic disruption experiments on static and rotating targets are reported. The experiments used cement spheres of diameter 10 cm as the targets. Impacts were by mm sized stainless steel spheres at speeds of between 1 and 7.75 km s-1. Energy densities (Q) in the targets ranged from 7 to 2613 J kg-1. The experiments covered both the cratering and catastrophic disruption regimes. For static, i.e. non-rotating targets the critical energy density for disruption (Q*, the value of Q when the largest surviving target fragment has a mass equal to one half of the pre-impact target mass) was Q* = 1447 ± 90 J kg-1. For rotating targets (median rotation frequency of 3.44 Hz) we found Q* = 987 ± 349 J kg-1, a reduction of 32% in the mean value. This lower value of Q* for rotating targets was also accompanied by a larger scatter on the data, hence the greater uncertainty. We suggest that in some cases the rotating targets behaved as static targets, i.e. broke up with the same catastrophic disruption threshold, but in other cases the rotation helped the break up causing a lower catastrophic disruption threshold, hence both the lower value of Q* and the larger scatter on the data. The fragment mass distributions after impact were similar in both the static and rotating target experiments with similar slopes.

  9. IMPLICATIONS OF RAPID CORE ROTATION IN RED GIANTS FOR INTERNAL ANGULAR MOMENTUM TRANSPORT IN STARS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tayar, Jamie; Pinsonneault, Marc H., E-mail: tayar.1@osu.edu

    2013-09-20

    Core rotation rates have been measured for red giant stars using asteroseismology. These data, along with helioseismic measurements and open cluster spin-down studies, provide powerful clues about the nature and timescale for internal angular momentum transport in stars. We focus on two cases: the metal-poor red giant KIC 7341231 ({sup O}tto{sup )} and intermediate-mass core helium burning stars. For both, we examine limiting case studies for angular momentum coupling between cores and envelopes under the assumption of rigid rotation on the main sequence. We discuss the expected pattern of core rotation as a function of mass and radius. In themore » case of Otto, strong post-main-sequence coupling is ruled out and the measured core rotation rate is in the range of 23-33 times the surface value expected from standard spin-down models. The minimum coupling timescale (0.17-0.45 Gyr) is significantly longer than that inferred for young open cluster stars. This implies ineffective internal angular momentum transport in early first ascent giants. By contrast, the core rotation rates of evolved secondary clump stars are found to be consistent with strong coupling given their rapid main-sequence rotation. An extrapolation to the white dwarf regime predicts rotation periods between 330 and 0.0052 days, depending on mass and decoupling time. We identify two key ingredients that explain these features: the presence of a convective core and inefficient angular momentum transport in the presence of larger mean molecular weight gradients. Observational tests that can disentangle these effects are discussed.« less

  10. The determination of the operating range of a twin-grip control yoke through biomechanical means

    NASA Technical Reports Server (NTRS)

    Gaertner, K. P.

    1978-01-01

    A twin-grip control yoke was designed as an ergonomic case study that allows dual axis control inputs, both axes being rotational. Inputs are effected by rotating the grips. How the handles were designed with respect to their shape and size and how the angular range of the control yoke in both rotational axes was evaluated. The control yoke which requires two-hand operation was tested to determine its operating range. The intention of this investigation was to find out the optimal form of the control yoke and the maximum permissible range in both rotating axes. In these experiments controls had no spring resistance.

  11. REVIEWS OF TOPICAL PROBLEMS: Motion of particles and photons in the gravitational field of a rotating body (In memory of Vladimir Afanas'evich Ruban)

    NASA Astrophysics Data System (ADS)

    Dymnikova, I. G.

    1986-03-01

    A study is made of the trajectories of free motion of test particles and photons in the Kerr metric, which describes the gravitational field of a rotating massive body. The trajectories are classified on the basis of the integrals of the motion, which have a clear physical meaning. The cases of a strong gravitational field in the neighborhood of a rotating black hole as well as the weak-field approximation describing the motion of particles in the gravitational field of a rotating star or galaxy are considered. The review includes bound states (orbits) in the field of a rotating mass, scattering and gravitational capture of particles and photons by a rotating black hole, trajectories of falling into a black hole, and the bending of light rays and the gravitational time delay of signals in the gravitational field of a rotating body.

  12. Rotation of the vermis as a cause of enlarged cisterna magna on prenatal imaging.

    PubMed

    Zalel, Y; Gilboa, Y; Gabis, L; Ben-Sira, L; Hoffman, C; Wiener, Y; Achiron, R

    2006-05-01

    Dandy-Walker complex is a continuum of developmental anomalies of the posterior fossa which includes vermian rotation. However, vermian rotation alone may be benign. The aim of this study was to describe our experience with sagittal-plane prenatal ultrasound in the diagnosis of rotation of the vermis in cases of suspected enlarged cisterna magna on routine antenatal imaging, and to describe the follow-up of these patients. Seven women, who were referred to our ultrasound unit for evaluation of an enlarged fetal cisterna magna and suspected agenesis of the vermis on axial-plane imaging, underwent further multiplanar studies of the posterior fossa and measurements of the vermis. The mean maternal age was 27 (range, 20-33) years and the mean gestational age at diagnosis was 19.5 (range, 18-31) weeks. The standard axial plane image showed a 'direct communication' between the cisterna magna and the fourth ventricle. In the mid-sagittal plane, the vermis was clearly delineated, with posterosuperior rotation. Vermis size was within normal limits for gestational age in all cases. Findings were confirmed by prenatal magnetic resonance imaging (MRI) in two cases and postnatal MRI and/or sonography in five. During a mean follow-up of 4.5 (range, 1-7.5) years, all children developed normally, with no neurological complications. The finding of an enlarged cisterna magna on standard- (axial-)plane ultrasound should be evaluated further in the sagittal plane to determine whether the cause is rotation of a normal vermis. This may spare patients unnecessary tests, anxiety and, in some cases, pregnancy termination. Copyright 2006 ISUOG

  13. Symmetry analysis of trimers rovibrational spectra: the case of Ne3★

    NASA Astrophysics Data System (ADS)

    Márquez-Mijares, Maykel; Roncero, Octavio; Villarreal, Pablo; González-Lezana, Tomás

    2018-05-01

    An approximate method to assign the symmetry to the rovibrational spectrum of homonuclear trimers based on the solution of the rotational Hamiltonian by means of a purely vibrational basis combined with standard rotational functions is applied on Ne3. The neon trimer constitutes an ideal test between heavier systems such as Ar3 for which the method proves to be an extremely useful technique and some other previously investigated cases such as H3 + where some limitations were observed. Comparisons of the calculated rovibrational energy levels are established with results from different calculations reported in the literature.

  14. Evaluating the impact of a pre-rotation workshop on student preparation for clinical advanced pharmacy practice experiences.

    PubMed

    Medina, Melissa S; Stark, Jennifer E; Vesta, Kimi S; Lockhart, Staci M

    2008-10-01

    This pilot study was designed to evaluate the impact of a pre-rotation workshop (PRW) on pharmacy students' clinical skills and preparation for clinical Advanced Pharmacy Practice Experiences (APPE) involving direct patient care. Randomized controlled trial of an educational intervention with Institutional Review Board approval. PRW activities designed to simulate rotation activities around five competencies, patient charts, medication histories, SOAP notes, patient presentations, and professionalism. Endpoints were evaluated using clinical rotation preceptors' evaluation of performance and students' performance on objective structured clinical exams (OSCE). Eight fourth-year students and eight GPA matched controls (20% of the total class) were selected to voluntarily participate. The PRW demonstrated a positive impact on students' clinical skills and preparation for rotations by improving OSCE performance. However, no significant differences were found between groups when comparing preceptor evaluations of skills on rotations. These results are limited by the small sample size, potential OSCE "test-wiseness" effects, lack of OSCE evaluator blinding to study groups, potential case specificity effects due to the limited number of cases used on the OSCE and possible lack of sensitivity of the rotation evaluation tool to capture true differences among the experimental and control group participants. The PRW was successful at advancing students' clinical skills and preparation for rotations and may be considered as a tool to help bridge didactic to clinical experiences in the Pharm.D. curriculum.

  15. Association between rotation-related impairments and activity type in people with and without low back pain

    PubMed Central

    Weyrauch, Stephanie A.; Bohall, Sara C.; Sorensen, Christopher J.; Van Dillen, Linda R.

    2015-01-01

    Objective To determine if people with low back pain (LBP) who regularly participated in a rotation-related activity displayed more rotation-related impairments than people without LBP who did and did not participate in the activity. Design Secondary analysis of data from a case-control study. Setting Musculoskeletal analysis laboratory at an academic medical center. Participants A convenience sample of 55 participants with LBP who participated in a rotation-related sport, 26 back healthy controls who participated in a rotation-related sport (BHC+RRS) and 42 back healthy controls who did not participate in a rotation-related sport (BHC-RRS). Participants were matched based on age, gender, and activity level. Interventions Not applicable. Main Outcome Measures The total number of rotation-related impairments and asymmetric rotation-related impairments identified during a standardized clinical examination. Results Compared to the BHC-RRS group, both the LBP and BHC+RRS groups displayed significantly more (1) rotation-related impairments (LBP: p<.001; BHC+RRS: p=.015) (2) asymmetric rotation-related impairments (LBP: p=.006; BHC+RRS: p=.020) and (3) rotation-related impairments with trunk movement tests (LBP: p=.002; BHC+RRS: p<.001). The LBP group had significantly more rotation-related impairments with extremity movement tests than both of the back healthy groups (BHC+RRS: p=.011; BHC-RRS: p<.001). Conclusions LBP and BHC+RRS groups demonstrated a similar number of total rotation-related impairments and asymmetric rotation-related impairments, and these numbers were greater than those of the BHC-RRS group. Compared to people without LBP, people with LBP displayed more rotation-related impairments when moving an extremity. These findings suggest that impairments associated with extremity movements may be associated with having a LBP condition. PMID:25933914

  16. Solutions to Three-Dimensional Thin-Layer Navier-Stokes Equations in Rotating Coordinates for Flow Through Turbomachinery

    NASA Technical Reports Server (NTRS)

    Ghosh, Amrit Raj

    1996-01-01

    The viscous, Navier-Stokes solver for turbomachinery applications, MSUTC has been modified to include the rotating frame formulation. The three-dimensional thin-layer Navier-Stokes equations have been cast in a rotating Cartesian frame enabling the freezing of grid motion. This also allows the flow-field associated with an isolated rotor to be viewed as a steady-state problem. Consequently, local time stepping can be used to accelerate convergence. The formulation is validated by running NASA's Rotor 67 as the test case. results are compared between the rotating frame code and the absolute frame code. The use of the rotating frame approach greatly enhances the performance of the code with respect to savings in computing time, without degradation of the solution.

  17. Rapidly rotating neutron stars with a massive scalar field—structure and universal relations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doneva, Daniela D.; Yazadjiev, Stoytcho S., E-mail: daniela.doneva@uni-tuebingen.de, E-mail: yazad@phys.uni-sofia.bg

    We construct rapidly rotating neutron star models in scalar-tensor theories with a massive scalar field. The fact that the scalar field has nonzero mass leads to very interesting results since the allowed range of values of the coupling parameters is significantly broadened. Deviations from pure general relativity can be very large for values of the parameters that are in agreement with the observations. We found that the rapid rotation can magnify the differences several times compared to the static case. The universal relations between the normalized moment of inertia and quadrupole moment are also investigated both for the slowly andmore » rapidly rotating cases. The results show that these relations are still EOS independent up to a large extend and the deviations from pure general relativity can be large. This places the massive scalar-tensor theories amongst the few alternative theories of gravity that can be tested via the universal I -Love- Q relations.« less

  18. A numerical and experimental study of three-dimensional liquid sloshing in a rotating spherical container

    NASA Technical Reports Server (NTRS)

    Chen, Kuo-Huey; Kelecy, Franklyn J.; Pletcher, Richard H.

    1992-01-01

    A numerical and experimental study of three dimensional liquid sloshing inside a partially-filled spherical container undergoing an orbital rotating motion is described. Solutions of the unsteady, three-dimensional Navier-Stokes equations for the case of a gradual spin-up from rest are compared with experimental data obtained using a rotating test rig fitted with two liquid-filled spherical tanks. Data gathered from several experiments are reduced in terms of a dimensionless free surface height for comparison with transient results from the numerical simulations. The numerical solutions are found to compare favorably with the experimental data.

  19. Single rotating stars and the formation of bipolar planetary nebula

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    García-Segura, G.; Villaver, E.; Langer, N.

    2014-03-10

    We have computed new stellar evolution models that include the effects of rotation and magnetic torques under different hypotheses. The goal is to test whether a single star can sustain the rotational velocities needed in the envelope for magnetohydrodynamical(MHD) simulations to shape bipolar planetary nebulae (PNe) when high mass-loss rates take place. Stellar evolution models with main sequence masses of 2.5 and 5 M {sub ☉} and initial rotational velocities of 250 km s{sup –1} have been followed through the PNe formation phase. We find that stellar cores have to be spun down using magnetic torques in order to reproducemore » the rotation rates observed for white dwarfs. During the asymptotic giant branch phase and beyond, the magnetic braking of the core has a practically null effect on increasing the rotational velocity of the envelope since the stellar angular momentum is efficiently removed by the wind. We have also tested the best possible case scenarios in rather non-physical contexts to give enough angular momentum to the envelope. We find that we cannot get the envelope of a single star to rotate at the speeds needed for MHD simulations to form bipolar PNe. We conclude that single stellar rotators are unlikely to be the progenitors of bipolar PNe under the current MHD model paradigm.« less

  20. Non-synchronous rotating damping effects in gyroscopic rotating systems

    NASA Astrophysics Data System (ADS)

    Brusa, Eugenio; Zolfini, Giacomo

    2005-03-01

    The effects of non-synchronous rotating damping, i.e., of energy dissipation in elements rotating at a speed different from that of the main rotor, on the dynamic behaviour of the latter have been already studied in a previous paper (J. Rotating Machinery 6 (6) (2000)) for the case of non-gyroscopic rotating systems. A planar model, namely the Jeffcott's rotor, was used. The present study is aimed at investigating, through analytical and numerical models, the behaviour of rotors having a non-negligible gyroscopic effect. The parameters of the system affecting the dynamic stability are identified and the threshold of instability is then computed. A sort of map of stability is provided to allow mechanical engineers predicting possibile range of instability for forward and backward whirling motions. An experimental validation on a simple test rig is presented in order to show the effectiveness of the proposed stability analysis. Non-synchronous rotating damping is implemented by using a non-synchronous electromagnetic damper based on eddy currents.

  1. Reverse shoulder arthroplasty for massive rotator cuff tear: risk factors for poor functional improvement.

    PubMed

    Hartzler, Robert U; Steen, Brandon M; Hussey, Michael M; Cusick, Michael C; Cottrell, Benjamin J; Clark, Rachel E; Frankle, Mark A

    2015-11-01

    Some patients unexpectedly have poor functional improvement after reverse shoulder arthroplasty (RSA) for massive rotator cuff tear without glenohumeral arthritis. Our aim was to identify risk factors for this outcome. We also assessed the value of RSA for cases with poor functional improvement vs. The study was a retrospective case-control analysis for primary RSA performed for massive rotator cuff tear without glenohumeral arthritis with minimum 2-year follow-up. Cases were defined as Simple Shoulder Test (SST) score improvement of ≤1, whereas controls improved SST score ≥2. Risk factors were chosen on the basis of previous association with poor outcomes after shoulder arthroplasty. Latissimus dorsi tendon transfer results were analyzed as a subgroup. Value was defined as improvement in American Shoulder and Elbow Surgeons (ASES) score per $10,000 hospital cost. In a multivariate binomial logistic regression analysis, neurologic dysfunction (P = .006), age <60 years (P = .02), and high preoperative SST score (P = .03) were independently associated with poor functional improvement. Latissimus dorsi tendon transfer patients significantly improved in active external rotation (-0.3° to 38.7°; P < .01). The value of RSA (ΔASES/$10,000 cost) for cases was 0.8 compared with 17.5 for controls (P < .0001). Young age, high preoperative function, and neurologic dysfunction were associated with poor functional improvement. Surgeons should consider these associations in counseling and selection of patients. Concurrent latissimus dorsi transfer was successful in restoring active external rotation in a subgroup of patients. The critical economic importance of improved patient selection is emphasized by the very low value of the procedure in the case group. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  2. Evidence for Cluster to Cluster Variations in Low-mass Stellar Rotational Evolution

    NASA Astrophysics Data System (ADS)

    Coker, Carl T.; Pinsonneault, Marc; Terndrup, Donald M.

    2016-12-01

    The concordance model for angular momentum evolution postulates that star-forming regions and clusters are an evolutionary sequence that can be modeled with assumptions about protostar-disk coupling, angular momentum loss from magnetized winds that saturates in a mass-dependent fashion at high rotation rates, and core-envelope decoupling for solar analogs. We test this approach by combining established data with the large h Per data set from the MONITOR project and new low-mass Pleiades data. We confirm prior results that young low-mass stars can be used to test star-disk coupling and angular momentum loss independent of the treatment of internal angular momentum transport. For slow rotators, we confirm the need for star-disk interactions to evolve the ONC to older systems, using h Per (age 13 Myr) as our natural post-disk case. There is no evidence for extremely long-lived disks as an alternative to core-envelope decoupling. However, our wind models cannot evolve rapid rotators from h Per to older systems consistently, and we find that this result is robust with respect to the choice of angular momentum loss prescription. We outline two possible solutions: either there is cosmic variance in the distribution of stellar rotation rates in different clusters or there are substantially enhanced torques in low-mass rapid rotators. We favor the former explanation and discuss observational tests that could be used to distinguish them. If the distribution of initial conditions depends on environment, models that test parameters by assuming a universal underlying distribution of initial conditions will need to be re-evaluated.

  3. Evaluation of the vibrational behaviour of a rotating disk by optical tip-clearance measurements

    NASA Astrophysics Data System (ADS)

    García, Iker; Zubia, Joseba; Beloki, Josu; Arrue, Jon; Villatoro, Joel

    2015-05-01

    The results of an experimental investigation on the vibrational behaviour of a rotating disk are reported. This disk is a prototype that simulates a component of an aircraft engine. The air flow through the gap between the edge of the disk and the casing, produced because of the pressure difference between the upstream and downstream parts of the disk, might force the disk to flutter under certain circumstances. This situation is simulated in a wind tunnel. The main goal of the tests is to evaluate the vibrational behaviour of a rotating disk, obtaining the correspondence between the vibration frequencies of the disk and the pressure differences when the disk is rotating at diverse speeds. An innovative noncontact technique is utilised, which employs three optical sensors that are angularly equidistributed on the casing of the wind tunnel. In order to verify the results given by the optical sensors, a strain gauge was mounted on the surface of the rotating disk. The results show a perfect agreement between the vibration frequencies detected by both kinds of sensors, proving that the combination of both allows the calculation of the nodal diameter corresponding to the vibration of the disk.

  4. Instrumental rotation for persistent fetal occiput posterior position: a way to decrease maternal and neonatal injury?

    PubMed

    Vidal, Fabien; Simon, Caroline; Cristini, Christelle; Arnaud, Catherine; Parant, Olivier

    2013-01-01

    To evaluate immediate perineal and neonatal morbidity associated with instrumental rotations performed with Thierry's spatulas for the management of persistent posterior occiput (OP) positions. Retrospective study including all persistent occiput posterior positions with vaginal OP delivery, from August 2006 to September 2007. Occiput anterior deliveries following successful instrumental rotation were included as well. We compared maternal and neonatal immediate outcomes between spontaneous deliveries, rotational and non rotational assisted deliveries, using χ(2) and Anova tests. 157 patients were enrolled, comprising 46 OP spontaneous deliveries, 58 assisted OP deliveries and 53 deliveries after rotational procedure. Instrumental rotation failed in 9 cases. Mean age and parity were significantly higher in the spontaneous delivery group, while labor duration was shorter. There were no significant differences in the rate of severe perineal tears and neonatal adverse outcomes between the 3 groups. Instrumental rotation using Thierry's spatulas was not associated with a reduced risk of maternal and neonatal morbidity for persistent OP deliveries. Further studies are required to define the true interest of such procedure in modern obstetrics.

  5. Instrumental Rotation for Persistent Fetal Occiput Posterior Position: A Way to Decrease Maternal and Neonatal Injury?

    PubMed Central

    Vidal, Fabien; Simon, Caroline; Cristini, Christelle; Arnaud, Catherine; Parant, Olivier

    2013-01-01

    Objective To evaluate immediate perineal and neonatal morbidity associated with instrumental rotations performed with Thierry’s spatulas for the management of persistent posterior occiput (OP) positions. Methods Retrospective study including all persistent occiput posterior positions with vaginal OP delivery, from August 2006 to September 2007. Occiput anterior deliveries following successful instrumental rotation were included as well. We compared maternal and neonatal immediate outcomes between spontaneous deliveries, rotational and non rotational assisted deliveries, using χ2 and Anova tests. Results 157 patients were enrolled, comprising 46 OP spontaneous deliveries, 58 assisted OP deliveries and 53 deliveries after rotational procedure. Instrumental rotation failed in 9 cases. Mean age and parity were significantly higher in the spontaneous delivery group, while labor duration was shorter. There were no significant differences in the rate of severe perineal tears and neonatal adverse outcomes between the 3 groups. Conclusion Instrumental rotation using Thierry’s spatulas was not associated with a reduced risk of maternal and neonatal morbidity for persistent OP deliveries. Further studies are required to define the true interest of such procedure in modern obstetrics. PMID:24205122

  6. Large Scale Flutter Data for Design of Rotating Blades Using Navier-Stokes Equations

    NASA Technical Reports Server (NTRS)

    Guruswamy, Guru P.

    2012-01-01

    A procedure to compute flutter boundaries of rotating blades is presented; a) Navier-Stokes equations. b) Frequency domain method compatible with industry practice. Procedure is initially validated: a) Unsteady loads with flapping wing experiment. b) Flutter boundary with fixed wing experiment. Large scale flutter computation is demonstrated for rotating blade: a) Single job submission script. b) Flutter boundary in 24 hour wall clock time with 100 cores. c) Linearly scalable with number of cores. Tested with 1000 cores that produced data in 25 hrs for 10 flutter boundaries. Further wall-clock speed-up is possible by performing parallel computations within each case.

  7. A Comparison of Trajectory Optimization Methods for the Impulsive Minimum Fuel Rendezvous Problem

    NASA Technical Reports Server (NTRS)

    Hughes, Steven P.; Mailhe, Laurie M.; Guzman, Jose J.

    2003-01-01

    In this paper we present, a comparison of trajectory optimization approaches for the minimum fuel rendezvous problem. Both indirect and direct methods are compared for a variety of test cases. The indirect approach is based on primer vector theory. The direct approaches are implemented numerically and include Sequential Quadratic Programming (SQP). Quasi- Newton and Nelder-Meade Simplex. Several cost function parameterizations are considered for the direct approach. We choose one direct approach that appears to be the most flexible. Both the direct and indirect methods are applied to a variety of test cases which are chosen to demonstrate the performance of each method in different flight regimes. The first test case is a simple circular-to-circular coplanar rendezvous. The second test case is an elliptic-to-elliptic line of apsides rotation. The final test case is an orbit phasing maneuver sequence in a highly elliptic orbit. For each test case we present a comparison of the performance of all methods we consider in this paper.

  8. Experimental test of nonlocal realistic theories without the rotational symmetry assumption.

    PubMed

    Paterek, Tomasz; Fedrizzi, Alessandro; Gröblacher, Simon; Jennewein, Thomas; Zukowski, Marek; Aspelmeyer, Markus; Zeilinger, Anton

    2007-11-23

    We analyze the class of nonlocal realistic theories that was originally considered by Leggett [Found. Phys. 33, 1469 (2003)10.1023/A:1026096313729] and tested by us in a recent experiment [Nature (London) 446, 871 (2007)10.1038/nature05677]. We derive an incompatibility theorem that works for finite numbers of polarizer settings and that does not require the previously assumed rotational symmetry of the two-particle correlation functions. The experimentally measured case involves seven different measurement settings. Using polarization-entangled photon pairs, we exclude this broader class of nonlocal realistic models by experimentally violating a new Leggett-type inequality by 80 standard deviations.

  9. Determination of rotor harmonic blade loads from acoustic measurements

    NASA Technical Reports Server (NTRS)

    Kasper, P. K.

    1975-01-01

    The magnitude of discrete frequency sound radiated by a rotating blade is strongly influenced by the presence of a nonuniform distribution of aerodynamic forces over the rotor disk. An analytical development and experimental results are provided for a technique by which harmonic blade loads are derived from acoustic measurements. The technique relates, on a one-to-one basis, the discrete frequency sound harmonic amplitudes measured at a point on the axis of rotation to the blade-load harmonic amplitudes. This technique was applied to acoustic data from two helicopter types and from a series of test results using the NASA-Langley Research Center rotor test facility. The inferred blade-load harmonics for the cases considered tended to follow an inverse power law relationship with harmonic blade-load number. Empirical curve fits to the data showed the harmonic fall-off rate to be in the range of 6 to 9 db per octave of harmonic order. These empirical relationships were subsequently used as input data in a compatible far field rotational noise prediction model. A comparison between predicted and measured off-axis sound harmonic levels is provided for the experimental cases considered.

  10. Magnetic field strengths in high-redshift galaxies - Can the galactic dynamo be tested?

    NASA Technical Reports Server (NTRS)

    Perry, Judith J.; Watson, Alan M.; Kronberg, Philipp P.

    1993-01-01

    The hypothesis that the population of strong H I absorption systems is responsible for a significant excess Faraday rotation measure in quasars is discussed, and it is concluded that the case is unproved, in contrast to a recent analysis by Wolf et al. (1991). The limitations and pitfalls inherent in attempts to derive firm magnetic field strengths from the existing integrated rotation measures of quasars are discussed, and it is shown that although it is premature to use integrated quasar rotation measures to either confirm or rule out particular mechanisms of magnetic field amplification in galaxy disks, the present observations may call for reexamination of current theories of large-scale magnetic field generation. The sources of rotation measure in the double quasar 0957+561 are also discussed.

  11. Graft Utilization in the Bridging Reconstruction of Irreparable Rotator Cuff Tears: A Systematic Review.

    PubMed

    Lewington, Matthew R; Ferguson, Devin P; Smith, T Duncan; Burks, Robert; Coady, Catherine; Wong, Ivan Ho-Bun

    2017-11-01

    Rotator cuff tears are one of the most common conditions affecting the shoulder. Because of the difficulty in managing massive rotator cuff tears and the inability of standard techniques to prevent arthropathy, surgeons have developed several novel techniques to improve outcomes and ideally alter the natural history. To systematically review the existing literature and analyze reported outcomes to evaluate the effectiveness of using a bridging graft reconstruction technique to treat large to massive irreparable rotator cuff tears. Systematic review. A systematic search of PubMed, EMBASE, CINAHL, and CENTRAL was employed with the key terms "tear," "allograft," and "rotator cuff." Eligibility was determined by a 3-phase screening process according to the outlined inclusion/exclusion criteria. Data in relation to the primary and secondary outcomes were summarized. The results were synthesized according to the origin of the graft and the level of evidence. Fifteen studies in total were included in this review: 2 comparative studies and 13 observational case series. Both the biceps tendon and the fascia lata autograft groups had significantly superior structural integrity rates on magnetic resonance imaging at 12-month minimum follow-up when compared with their partial primary repair counterparts (58% vs 26%, P = .036; 79% vs 58%, P < .05), respectively. Multiple noncomparative case series investigating allografts, xenografts, and synthetic materials for bridging reconstruction of large to massive rotator cuff tears demonstrated high structural healing rates (74%-90%, 73%-100%, and 60%-90%, respectively). Additionally, both comparative studies and case series demonstrated a general improvement of patients' functional outcome scores. Using a graft for an anatomic bridging rotator cuff repair results in improved function on objective testing and may be functionally better than nonanatomic or partial repair of large to massive rotator cuff tears. Allograft or xenograft techniques appear to be favorable options, given demonstrated functional improvement, imaging-supported graft survival, and lack of harvest complication risk. More high-quality randomized controlled studies are needed to further assess this technique.

  12. Analyzing the dynamic response of rotating blades in small-scale wind turbines

    NASA Astrophysics Data System (ADS)

    Hsiung, Wan-Ying; Huang, Yu-Ting; Loh, Chin-Hsiung; Loh, Kenneth J.; Kamisky, Robert J.; Nip, Danny; van Dam, Cornelis

    2014-03-01

    The objective of this study was to validate modal analysis, system identification and damage detection of small-scale rotating wind turbine blades in the laboratory and in the field. Here, wind turbine blades were instrumented with accelerometers and strain gages, and data acquisition was achieved using a prototype wireless sensing system. In the first portion of this study conducted in the laboratory, sensors were installed onto metallic structural elements that were fabricated to be representative of an actual wind blade. In order to control the excitation (rotation of the wind blade), a motor was used to spin the blades at controlled angular velocities. The wind turbine was installed on a shaking table for testing under rotation of turbine blades. Data measured by the sensors were recorded while the blade was operated at different speeds. On the other hand, the second part of this study utilized a small-scale wind turbine system mounted on the rooftop of a building. The main difference, as compared to the lab tests, was that the field tests relied on actual wind excitations (as opposed to a controlled motor). The raw data from both tests were analyzed using signal processing and system identification techniques for deriving the model response of the blades. The multivariate singular spectrum analysis (MSSA) and covariance-driven stochastic subspace identification method (SSI-COV) were used to identify the dynamic characteristics of the system. Damage of one turbine blade (loose bolts connection) in the lab test was also conducted. The extracted modal properties for both undamaged and damage cases under different ambient or forced excitations (earthquake loading) were compared. These tests confirmed that dynamic characterization of rotating wind turbines was feasible, and the results will guide future monitoring studies planned for larger-scale systems.

  13. Arthroscopic rotator cuff debridement without decompression for the treatment of tendinosis.

    PubMed

    Budoff, Jeffrey E; Rodin, Dennis; Ochiai, Derek; Nirschl, Robert P

    2005-09-01

    The treatment of rotator cuff injury in the absence of a full-thickness tear has traditionally consisted of acromioplasty. However, this disorder may also be treated by arthroscopic rotator cuff debridement without acromioplasty. Our previous study of 79 shoulders so treated reported 87% good or excellent results at an average 53-month follow-up. The purpose of this article is to report the long-term, average 9.5-year follow-up of this cohort. Long-term follow-up of case series. We retrospectively reviewed the records of 62 shoulders in 60 patients who had undergone arthroscopic rotator cuff debridement for partial-thickness rotator cuff tears. Demographic criteria, residual pain, and the ability to return to recreational athletics were noted. The UCLA Shoulder Score and the Simple Shoulder Test scores were determined and statistical analysis performed. Using the UCLA Shoulder Score, there were 79% excellent or good results at an average 114 months of follow-up. Patients with Workers' Compensation claims had significantly worse results, with only 40% rated good or excellent. Of the 60 patients, 77% had no or only minimal pain, 57% were still able to perform recreational athletics without difficulty, and 20% could participate at a lower level of intensity. Arthroscopic debridement of rotator cuff injury in the absence of a full-thickness tear has good long-term results and minimizes additional surgical trauma. Level IV, case series.

  14. EVIDENCE FOR CLUSTER TO CLUSTER VARIATIONS IN LOW-MASS STELLAR ROTATIONAL EVOLUTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coker, Carl T.; Pinsonneault, Marc; Terndrup, Donald M., E-mail: coker@astronomy.ohio-state.edu, E-mail: pinsono@astronomy.ohio-state.edu, E-mail: terndrup@astronomy.ohio-state.edu

    2016-12-10

    The concordance model for angular momentum evolution postulates that star-forming regions and clusters are an evolutionary sequence that can be modeled with assumptions about protostar–disk coupling, angular momentum loss from magnetized winds that saturates in a mass-dependent fashion at high rotation rates, and core-envelope decoupling for solar analogs. We test this approach by combining established data with the large h Per data set from the MONITOR project and new low-mass Pleiades data. We confirm prior results that young low-mass stars can be used to test star–disk coupling and angular momentum loss independent of the treatment of internal angular momentum transport.more » For slow rotators, we confirm the need for star–disk interactions to evolve the ONC to older systems, using h Per (age 13 Myr) as our natural post-disk case. There is no evidence for extremely long-lived disks as an alternative to core-envelope decoupling. However, our wind models cannot evolve rapid rotators from h Per to older systems consistently, and we find that this result is robust with respect to the choice of angular momentum loss prescription. We outline two possible solutions: either there is cosmic variance in the distribution of stellar rotation rates in different clusters or there are substantially enhanced torques in low-mass rapid rotators. We favor the former explanation and discuss observational tests that could be used to distinguish them. If the distribution of initial conditions depends on environment, models that test parameters by assuming a universal underlying distribution of initial conditions will need to be re-evaluated.« less

  15. Continuing Experiments on the Receptivity of Transient Disturbances to Surface Roughness and Freestream Turbulence

    DTIC Science & Technology

    2008-09-28

    rotating the spindle of the angle controller with a precision of 0.2°. The multiple-hotwire holder is designed to carry four hotwires. One hotwire is a...section and a maximum operating speed of 25 m/s. The tunnel’s design follows the recommendations of Reshotko et al. (1997) for flow quality. Operating at...This sting assembly includes a shaft that rotates in a streamlined casing and allows angular calibration of slanted hotwires. Outside the test

  16. Acoustic mode measurements in the inlet of a model turbofan using a continuously rotating rake

    NASA Astrophysics Data System (ADS)

    Heidelberg, Laurence J.; Hall, David G.

    1993-01-01

    Comprehensive measurements of the spinning acoustic mode structure in the inlet of the Advanced Ducted Propeller (ADP) have been completed. These measurements were taken using a unique and previously untried method which was first proposed by T.G. Sofrin. A continuously rotating microphone system was employed. The ADP model was designed and built by Pratt & Whitney and tested in the NASA Lewis 9- by 15-foot Anechoic Wind Tunnel. Three inlet configurations were tested with cut-on and cutoff stator vane sets. The cutoff stator was designed to suppress all modes at the blade passing frequency. Rotating rake measurements indicate that several extraneous circumferential modes were active. The mode orders suggest that their source was an interaction between the rotor and small interruptions in the casing tip treatment. The cut-on stator produced the expected circumferential modes plus higher levels of the unexpected modes seen with the cutoff stator.

  17. Acoustic Mode Measurements in the Inlet of a Model Turbofan Using a Continuously Rotating Rake

    NASA Technical Reports Server (NTRS)

    Heidelberg, Laurence J.; Hall, David G.

    1992-01-01

    Comprehensive measurements of the spinning acoustic mode structure in the inlet of the Advanced Ducted Propeller (ADP) have been completed. These measurements were taken using a unique and previously untried method which was first proposed by T.G. Sofrin. A continuously rotating microphone system was employed. The ADP model was designed and built by Pratt & Whitney and tested in the NASA Lewis 9- by 15-foot Anechoic Wind Tunnel. Three inlet configurations were tested with cut-on and cutoff stator vane sets. The cutoff stator was designed to suppress all modes at the blade passing frequency. Rotating rake measurements indicate that several extraneous circumferential modes were active. The mode orders suggest that their source was an interaction between the rotor and small interruptions in the casing tip treatment. The cut-on stator produced the expected circumferential modes plus higher levels of the unexpected modes seen with the cutoff stator.

  18. Optometric Grand Rounds.

    ERIC Educational Resources Information Center

    Townsend, John C.; Selvin, Gerald J.

    1988-01-01

    A clinical program developed for Veterans Administration optometry residents and rotating Southern California College of Optometry interns consisted of clinical patient examination followed by case discussion, a formal lecture corresponding to the ocular and systemic diseases presented in the examination, and student testing. (MSE)

  19. Estimation of attitude sensor timetag biases

    NASA Technical Reports Server (NTRS)

    Sedlak, J.

    1995-01-01

    This paper presents an extended Kalman filter for estimating attitude sensor timing errors. Spacecraft attitude is determined by finding the mean rotation from a set of reference vectors in inertial space to the corresponding observed vectors in the body frame. Any timing errors in the observations can lead to attitude errors if either the spacecraft is rotating or the reference vectors themselves vary with time. The state vector here consists of the attitude quaternion, timetag biases, and, optionally, gyro drift rate biases. The filter models the timetags as random walk processes: their expectation values propagate as constants and white noise contributes to their covariance. Thus, this filter is applicable to cases where the true timing errors are constant or slowly varying. The observability of the state vector is studied first through an examination of the algebraic observability condition and then through several examples with simulated star tracker timing errors. The examples use both simulated and actual flight data from the Extreme Ultraviolet Explorer (EUVE). The flight data come from times when EUVE had a constant rotation rate, while the simulated data feature large angle attitude maneuvers. The tests include cases with timetag errors on one or two sensors, both constant and time-varying, and with and without gyro bias errors. Due to EUVE's sensor geometry, the observability of the state vector is severely limited when the spacecraft rotation rate is constant. In the absence of attitude maneuvers, the state elements are highly correlated, and the state estimate is unreliable. The estimates are particularly sensitive to filter mistuning in this case. The EUVE geometry, though, is a degenerate case having coplanar sensors and rotation vector. Observability is much improved and the filter performs well when the rate is either varying or noncoplanar with the sensors, as during a slew. Even with bad geometry and constant rates, if gyro biases are independently known, the timetag error for a single sensor can be accurately estimated as long as its boresight is not too close to the spacecraft rotation axis.

  20. Patellofemoral pain and asymmetrical hip rotation.

    PubMed

    Cibulka, Michael T; Threlkeld-Watkins, Julie

    2005-11-01

    Patellofemoral joint problems are the most common overuse injury of the lower extremity, and altered femoral or hip rotation may play a role in patellofemoral pain. The purpose of this case report is to describe the evaluation of and intervention for a patient with asymmetrical hip rotation and patellofemoral pain. The patient was a 15-year-old girl with an 8-month history of anterior right knee pain, without known trauma or injury. Prior to intervention, her score on the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) was 24%. Right hip medial (internal) rotation was less than left hip medial rotation, and manual muscle testing showed weakness of the right hip internal rotator and abductor muscles. The intervention was aimed at increasing right hip medial rotation, improving right hip muscle strength (eg, the muscle force exerted by a muscle or a group of muscles to overcome a resistance), and eliminating anterior right knee pain. After 6 visits (14 days), passive left and right hip medial rotations were symmetrical, and her right hip internal rotator and abductor muscle grades were Good plus. Her WOMAC score was 0%. The patient had right patellofemoral pain and an uncommon pattern of asymmetrical hip rotation, with diminished hip medial rotation and excessive hip lateral (external) rotation on the right side. The patient's outcomes suggest that femoral or hip joint asymmetry may be related to patellofemoral joint pain.

  1. Are pain location and physical examinations useful in locating a tear site of the rotator cuff?

    PubMed

    Itoi, Eiji; Minagawa, Hiroshi; Yamamoto, Nobuyuki; Seki, Nobutoshi; Abe, Hidekazu

    2006-02-01

    Pain is the most common symptom of patients with rotator cuff tendinopathy, but little is known about the relationship between the site of pain and the site of cuff pathologic lesions. Also, accuracies of physical examinations used to locate a tear by assessing the muscle strength seem to be affected by the threshold for muscle weakness, but no studies have been reported regarding the efficacies of physical examinations in reference to their threshold. Pain location is useful in locating a tear site. Efficacies of physical examinations to evaluate the function of the cuff muscles depend on the threshold for muscle weakness. Case series; Level of evidence, 4. The authors retrospectively reviewed the clinical charts of 160 shoulders of 149 patients (mean age, 53 years) with either rotator cuff tears (140 shoulders) or cuff tendinitis (20 shoulders). The location of pain was recorded on a standardized form with 6 different areas. The diagnostic accuracies of the following tests were assessed with various thresholds for muscle weakness: supraspinatus test, the external rotation strength test, and the lift-off test. Lateral and anterior portions of the shoulder were the most common sites of pain regardless of existence of tear or tear location. The supraspinatus test was most accurate when it was assessed to have positive results with the muscle strength less than manual muscle testing grade 5, whereas the lift-off test was most accurate with a threshold less than grade 3. The external rotation strength test was most accurate with a threshold of less than grade 4+. The authors conclude that pain location is not useful in locating the site of a tear, whereas the physical examinations aiming to locate the tear site are clinically useful when assessed to have positive results with appropriate threshold for muscle weakness.

  2. Shoulder internal rotation elbow flexion test for diagnosing cubital tunnel syndrome.

    PubMed

    Ochi, Kensuke; Horiuchi, Yukio; Tanabe, Aya; Waseda, Makoto; Kaneko, Yasuhito; Koyanagi, Takahiro

    2012-06-01

    Shoulder internal rotation enhances symptom provocation attributed to cubital tunnel syndrome. We present a modified elbow flexion test--the shoulder internal rotation elbow flexion test--for diagnosing cubital tunnel syndrome. Fifty-five ulnar nerves in cubital tunnel syndrome patients and 123 ulnar nerves in controls were examined with 5 seconds each of elbow flexion, shoulder internal rotation, and shoulder internal rotation elbow flexion tests before and after treatment (surgery in 18; conservative in others). For the shoulder internal rotation elbow flexion test position, 90° abduction, maximum internal rotation, and 10° flexion of the shoulder were combined with the elbow flexion test position. The test was considered positive if any symptom for cubital tunnel syndrome developed <5 seconds. Influence of the shoulder internal rotation elbow flexion test was evaluated by nerve conduction studies in 10 cubital tunnel syndrome nerves and 7 control nerves. The sensitivities/specificities of the 5-second elbow flexion, shoulder internal rotation, and shoulder internal rotation elbow flexion tests were 25%/100%, 58%/100%, and 87%/98%, respectively. Sensitivity differences between the shoulder internal rotation elbow flexion test and the other two tests were significant. Shoulder internal rotation elbow flexion test results and cubital tunnel syndrome symptoms were significantly correlated. Influence of the shoulder internal rotation elbow flexion test on the ulnar nerve was seen in 8 of 10 cubital tunnel syndrome nerves but not in controls. The 5-second shoulder internal rotation elbow flexion test is specific, easy and quick provocative test for diagnosing cubital tunnel syndrome. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  3. A Bizarre, Unexplained, and Progressive External Rotation of the Shoulder as a Presentation of a Metastatic Deposit in the Rotator Cuff.

    PubMed

    El-Tawil, Sherif; Prinja, Aditya; Stanton, Jeremy

    2015-01-01

    We describe the first reported case of a tumour deposit within the rotator cuff presenting as a bizarre, progressive, and fixed external rotation deformity of the shoulder. It is also the first reported case to our knowledge of an oesophageal primary metastasising to the rotator cuff.

  4. Robust registration in case of different scaling

    NASA Astrophysics Data System (ADS)

    Gluhchev, Georgi J.; Shalev, Shlomo

    1993-09-01

    The problem of robust registration in the case of anisotropic scaling has been investigated. Registration of two images using corresponding sets of fiducial points is sensitive to inaccuracies in point placement due to poor image quality or non-rigid distortions, including possible out-of-plane rotations. An approach aimed at the detection of the most unreliable points has been developed. It is based on the a priori knowledge of the sequential ordering of rotation and scaling. A measure of guilt derived from the anomalous geometric relationships is introduced. A heuristic decision rule allowing for deletion of the most guilty points is proposed. The approach allows for more precise evaluation of the translation vector. It has been tested on phantom images with known parameters and has shown satisfactory results.

  5. Vertical Force-deflection Characteristics of a Pair of 56-inch-diameter Aircraft Tires from Static and Drop Tests with and Without Prerotation

    NASA Technical Reports Server (NTRS)

    Smiley, Robert F; Horne, Walter B

    1957-01-01

    The vertical force-deflection characteristics were experimentally determined for a pair of 56-inch-diameter tires under static and drop-test conditions with and without prerotation. For increasing force, the tires were found to be least stiff for static tests, almost the same as for the static case for prerotation drop tests as long as the tires remain rotating, and appreciably stiffer for drop tests without prerotation.

  6. Laminar Flow About a Rotating Body of Revolution in an Axial Airstream

    NASA Technical Reports Server (NTRS)

    Schlichting, H.

    1956-01-01

    We have set ourselves the problem of calculating the laminar flow on a body of revolution in an axial flow which simultaneously rotates about its axis. The problem mentioned above, the flow about a rotating disk in a flow, which we solved some time ago, represents the first step in the calculation of the flow on the rotating body of revolution in a flow insofar as, in the case of a round nose, a small region about the front stagnation point of the body of revolution may be replaced by its tangential plane. In our problem regarding the rotating body of revolution in a flow, for laminar flow, one of the limiting cases is known: that of the body which is in an axial approach flow but does not rotate. The other limiting case, namely the flow in the neighborhood of a body which rotates but is not subjected to a flow is known only for the rotating circular cylinder, aside from the rotating disk. In the case of the cylinder one deals with a distribution of the circumferential velocity according to the law v = omega R(exp 2)/r where R signifies the cylinder radius, r the distance from the center, and omega the angular velocity of the rotation. The velocity distribution as it is produced here by the friction effect is therefore the same as in the neighborhood of a potential vortex. When we treat, in what follows, the general case of the rotating body of revolution in a flow according to the calculation methods of Prandtl's boundary-layer theory, we must keep in mind that this solution cannot contain the limiting case of the body of revolution which only rotates but is not subjected to a flow. However, this is no essential limitation since this case is not of particular importance for practical purposes.

  7. A Bizarre, Unexplained, and Progressive External Rotation of the Shoulder as a Presentation of a Metastatic Deposit in the Rotator Cuff

    PubMed Central

    El-Tawil, Sherif; Prinja, Aditya; Stanton, Jeremy

    2015-01-01

    We describe the first reported case of a tumour deposit within the rotator cuff presenting as a bizarre, progressive, and fixed external rotation deformity of the shoulder. It is also the first reported case to our knowledge of an oesophageal primary metastasising to the rotator cuff. PMID:26543658

  8. A projection-based model reduction strategy for the wave and vibration analysis of rotating periodic structures

    NASA Astrophysics Data System (ADS)

    Beli, D.; Mencik, J.-M.; Silva, P. B.; Arruda, J. R. F.

    2018-05-01

    The wave finite element method has proved to be an efficient and accurate numerical tool to perform the free and forced vibration analysis of linear reciprocal periodic structures, i.e. those conforming to symmetrical wave fields. In this paper, its use is extended to the analysis of rotating periodic structures, which, due to the gyroscopic effect, exhibit asymmetric wave propagation. A projection-based strategy which uses reduced symplectic wave basis is employed, which provides a well-conditioned eigenproblem for computing waves in rotating periodic structures. The proposed formulation is applied to the free and forced response analysis of homogeneous, multi-layered and phononic ring structures. In all test cases, the following features are highlighted: well-conditioned dispersion diagrams, good accuracy, and low computational time. The proposed strategy is particularly convenient in the simulation of rotating structures when parametric analysis for several rotational speeds is usually required, e.g. for calculating Campbell diagrams. This provides an efficient and flexible framework for the analysis of rotordynamic problems.

  9. Numerical Investigation of a Two-Stage Counter-Rotating Turbine with Transition Modeling and Prediction Improvement with Time-Accurate Calculations

    DTIC Science & Technology

    2014-09-19

    by a shrouded counter-rotating low pressure (LP) rotor. The TMTF de- sign used in this test case was developed by Volvo Aero (recently acquired by...circumferential direction by the vanes (HPV) before entering the rotor. It leaves the rotor (HPR) with a negative swirl which dif- fers between hub and shroud ...with five-hole probes , which were traversed radi- ally over 90% of the blade height and over one HP vane pitch on plane C and over one TMTF strut

  10. The Role of the Away Rotation in Otolaryngology Residency.

    PubMed

    Villwock, Jennifer A; Hamill, Chelsea S; Ryan, Jesse T; Nicholas, Brian D

    2017-06-01

    Objective To determine the availability and purpose of away rotations during otolaryngology residency. Study Design Cross-sectional survey. Setting Otolaryngology residency programs. Subjects and Methods An anonymous web-based survey was sent to 98 allopathic otolaryngology training program directors, of which 38 programs responded. Fisher exact tests and nonparametric correlations were used to determine statistically significant differences among various strata of programs. A P value of <.05 was considered statistically significant. Results Thirty-nine percent (n = 38) of queried programs responded. Mandatory away rotations and elective away rotations were both present in 6 of 38 programs (16%). Neither number of faculty ( P = .119) nor residents ( P = .88) was predictive of away rotation. Away rotations were typically >151 miles from the home institution and typically used to address deficiencies in clinical exposure (67%) or case volume (50%). Participants of mandatory away rotations were universally provided housing, with other consideration such as stipend (33%), relocation allowance (33%), or food allowance (16%) sometimes offered. In contrast to mandatory rotations, half of elective rotations were to obtain a unique international mission trip experience. Nearly one-third of surveyed program directors (29%) would consider adding an away rotation to their curriculum in the next 3 years. Conclusions Mandatory and elective away rotations play a role in a small, but not insignificant, number of training programs. The rationale for these rotations is variable. Given that nearly one-third of program directors would consider adding an away rotation in the near future, further research into components of a meaningful away rotation and how to optimize the away rotation experience is warranted.

  11. Ballistic and Cyclic Rig Testing of Braided Composite Fan Case Structures

    NASA Technical Reports Server (NTRS)

    Watson, William R.; Roberts, Gary D.; Pereira, J. Michael; Braley, Michael S.

    2015-01-01

    FAA fan blade-out certification testing on turbofan engines occurs very late in an engine's development program and is very costly. It is of utmost importance to approach the FAA Certification engine test with a high degree of confidence that the containment structure will not only contain the high-energy debris, but that it will also withstand the cyclic loads that occur with engine spooldown and continued rotation as the non-running engine maintains a low rotor RPM due to forced airflow as the engine-out aircraft returns to an airport. Accurate rig testing is needed for predicting and understanding material behavior of the fan case structure during all phases of this fan blade-out event.

  12. Finite element investigation of the effect of a bifid arch on loading of the vertebral isthmus.

    PubMed

    Quah, Conal; Yeoman, Mark S; Cizinauskas, Andrius; Cooper, Kevin C; Peirce, Nick S; McNally, Donal S; Boszczyk, Bronek M

    2014-04-01

    The biomechanical effect of a bifid arch as seen in spina bifida occulta and following a midline laminectomy is poorly understood. To test the hypothesis that fatigue failure limits will be exceeded in the case of a bifid arch, but not in the intact case, when the segment is subjected to complex loading corresponding to normal sporting activities. Finite element analysis. Finite element model of an intact L4-S1 human lumbar motion segment including ligaments was used. A section of the L5 vertebral arch and spinous process was removed to create the model with a midline defect. The models were loaded axially to 1 kN and then combined with axial rotation of 3°. Bilateral stresses, alternating stresses, and shear fatigue failure on both models were assessed and compared. Under 1 kN axial load, the von Mises stresses observed in midline defect case and in the intact case were very similar (differences <5 MPa) having a maximum at the ventral end of the isthmus that decreases monotonically to the dorsal end. However, under 1 kN axial load and rotation, the maximum von Mises stresses observed in the ipsilateral L5 isthmus in the midline defect case (31 MPa) was much higher than the intact case (24.2 MPa), indicating a lack of load sharing across the vertebral arch in the midline defect case. When assessing the equivalent alternating shear stress amplitude, this was found to be 22.6 MPa for the midline defect case and 13.6 MPa for the intact case. From this, it is estimated that shear fatigue failure will occur in less than 70,000 cycles, under repetitive axial load and rotation conditions in the midline defect case, whereas for the intact case, fatigue failure will occur only after more than 10 million cycles. A bifid arch predisposes the isthmus to early fatigue fracture by generating increased stresses across the inferior isthmus of the inferior articular process, specifically in combined axial rotation and anteroposterior shear. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.

    PubMed

    Hayeri, Mohammad Reza; Keefe, Daniel T; Chang, Eric Y

    2016-05-01

    Rotator cuff repair using a suture bridge and knotless suture anchors is a relatively new, but increasingly used technique. The suture bridge technique creates an anatomically similar and more secure rotator cuff repair compared with conventional arthroscopic techniques and the use of knotless anchors eliminates the challenges associated with knot tying during arthroscopic surgery. However, previous in vitro biomechanical tests have shown that the hold of the suture in a knotless suture anchor is far lower than the pullout strength of the anchor from bone. Up until now slippage has been a theoretical concern. We present a prospectively diagnosed case of in vivo suture loosening after rotator cuff repair using a knotless bridge technique resulting in subacromial-subdeltoid bursitis.

  14. Error Field Assessment from Driven Mode Rotation: Results from Extrap-T2R Reversed-Field-Pinch and Perspectives for ITER

    NASA Astrophysics Data System (ADS)

    Volpe, F. A.; Frassinetti, L.; Brunsell, P. R.; Drake, J. R.; Olofsson, K. E. J.

    2012-10-01

    A new ITER-relevant non-disruptive error field (EF) assessment technique not restricted to low density and thus low beta was demonstrated at the Extrap-T2R reversed field pinch. Resistive Wall Modes (RWMs) were generated and their rotation sustained by rotating magnetic perturbations. In particular, stable modes of toroidal mode number n=8 and 10 and unstable modes of n=1 were used in this experiment. Due to finite EFs, and in spite of the applied perturbations rotating uniformly and having constant amplitude, the RWMs were observed to rotate non-uniformly and be modulated in amplitude (in the case of unstable modes, the observed oscillation was superimposed to the mode growth). This behavior was used to infer the amplitude and toroidal phase of n=1, 8 and 10 EFs. The method was first tested against known, deliberately applied EFs, and then against actual intrinsic EFs. Applying equal and opposite corrections resulted in longer discharges and more uniform mode rotation, indicating good EF compensation. The results agree with a simple theoretical model. Extensions to tearing modes, to the non-uniform plasma response to rotating perturbations, and to tokamaks, including ITER, will be discussed.

  15. Monitoring techniques for the X-29A aircraft's high-speed rotating power takeoff shaft

    NASA Technical Reports Server (NTRS)

    Voracek, David F.

    1990-01-01

    The experimental X-29A forward swept-wing aircraft has many unique and critical systems that require constant monitoring during ground or flight operation. One such system is the power takeoff shaft, which is the mechanical link between the engine and the aircraft-mounted accessory drive. The X-29A power takeoff shaft opertes in a range between 0 and 16,810 rpm, is longer than most jet engine power takeoff shafts, and is made of graphite epoxy material. Since the X-29A aircraft operates on a single engine, failure of the shaft during flight could lead to loss of the aircraft. The monitoring techniques and test methods used during power takeoff shaft ground and flight operations are discussed. Test data are presented in two case studies where monitoring and testing of the shaft dynamics proved instrumental in discovering and isolating X-29A power takeoff shaft problems. The first study concerns the installation of an unbalanced shaft. The effect of the unbalance on the shaft vibration data and the procedure used to correct the problem are discussed. The second study deals with the shaft exceeding the established vibration limits during flight. This case study found that the vibration of connected rotating machinery unbalances contributed to the excessive vibration level of the shaft. The procedures used to identify the contributions of other rotating machinery unbalances to the power takeoff shaft unbalance are discussed.

  16. The investigation of tethered satellite system dynamics

    NASA Technical Reports Server (NTRS)

    Lorenzini, E. C.

    1986-01-01

    The analysis of the rotational dynamics of the satellite was focused on the rotational amplitude increase of the satellite, with respect to the tether, during retrieval. The dependence of the rotational amplitude upon the tether tension variation to the power 1/4 was thoroughly investigated. The damping of rotational oscillations achievable by reel control was also quantified while an alternative solution that makes use of a lever arm attached with a universal joint to the satellite was proposed. Comparison simulations between the Smithsonian Astrophysical Observatory and the Martin Marietta (MMA) computer code of reteival maneuvers were also carried out. The agreement between the two, completely independent, codes was extremely close, demonstrating the reliability of the models. The slack tether dynamics during reel jams was analytically investigated in order to identify the limits of applicability of the SLACK3 computer code to this particular case. Test runs with SLACK3 were also carried out.

  17. Calculation of Expectation Values of Operators in the Complex Scaling Method

    DOE PAGES

    Papadimitriou, G.

    2016-06-14

    In the complex scaling method (CSM) provides with a way to obtain resonance parameters of particle unstable states by rotating the coordinates and momenta of the original Hamiltonian. It is convenient to use an L 2 integrable basis to resolve the complex rotated or complex scaled Hamiltonian H θ , with θ being the angle of rotation in the complex energy plane. Within the CSM, resonance and scattering solutions have fall-off asymptotics. Furthermore, one of the consequences is that, expectation values of operators in a resonance or scattering complex scaled solution are calculated by complex rotating the operators. In thismore » work we are exploring applications of the CSM on calculations of expectation values of quantum mechanical operators by using the regularized backrotation technique and calculating hence the expectation value using the unrotated operator. Moreover, the test cases involve a schematic two-body Gaussian model and also applications using realistic interactions.« less

  18. A method of determining attitude from magnetometer data only

    NASA Technical Reports Server (NTRS)

    Natanson, G. A.; Mclaughlin, S. F.; Nicklas, R. C.

    1990-01-01

    Presented here is a new algorithm to determine attitude using only magnetometer data under the following conditions: (1) internal torques are known and (2) external torques are negligible. Torque-free rotation of a spacecraft in thruster firing acquisition phase and its magnetic despin in the B-dot mode give typical examples of such situations. A simple analytical formula has been derived in the limiting case of a spacecraft rotating with constant angular velocity. The formula has been tested using low-frequency telemetry data for the Earth Radiation Budget Satellite (ERBS) under normal conditions. Observed small oscillation of body-fixed components of the angular velocity vector near their mean values result in relatively minor errors of approximately 5 degrees. More significant errors come from processing digital magnetometer data. Higher resolution of digitized magnetometer measurements would significantly improve the accuracy of this deterministic scheme. Tests of the general version of the developed algorithm for a free-rotating spacecraft and for the B-dot mode are in progress.

  19. Analysis on accuracy improvement of rotor-stator rubbing localization based on acoustic emission beamforming method.

    PubMed

    He, Tian; Xiao, Denghong; Pan, Qiang; Liu, Xiandong; Shan, Yingchun

    2014-01-01

    This paper attempts to introduce an improved acoustic emission (AE) beamforming method to localize rotor-stator rubbing fault in rotating machinery. To investigate the propagation characteristics of acoustic emission signals in casing shell plate of rotating machinery, the plate wave theory is used in a thin plate. A simulation is conducted and its result shows the localization accuracy of beamforming depends on multi-mode, dispersion, velocity and array dimension. In order to reduce the effect of propagation characteristics on the source localization, an AE signal pre-process method is introduced by combining plate wave theory and wavelet packet transform. And the revised localization velocity to reduce effect of array size is presented. The accuracy of rubbing localization based on beamforming and the improved method of present paper are compared by the rubbing test carried on a test table of rotating machinery. The results indicate that the improved method can localize rub fault effectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Using a Multimedia Tool to Improve Cardiac Auscultation Knowledge and Skills

    PubMed Central

    Stern, David T; Mangrulkar, Rajesh S; Gruppen, Larry D; Lang, Angela L; Grum, Cyril M; Judge, Richard D

    2001-01-01

    OBJECTIVE Today's medical school graduates have significant deficits in physical examination skills. Medical educators have been searching for methods to effectively teach and maintain these skills in students. The objective of this study was to determine if an auscultation curriculum centered on a portable multimedia CD-ROM was effective in producing and maintaining significant gains in cardiac auscultatory skills. DESIGN Controlled cohort study PARTICIPANTS All 168 third-year medical students at 1 medical school in an academic medical center. INTERVENTIONS Students were tested before and after exposure to 1 or more elements of the auscultation curriculum: teaching on ward/clinic rotations, CD-ROM comprehensive cases with follow-up seminars, and a CD-ROM 20-case miniseries. The primary outcome measures were student performance on a 10-item test of auscultation skill (listening and identifying heart sound characteristics) and a 30-item test of auscultation knowledge (factual questions about auscultation). A subset of students was tested for attenuation effects 9 or 12 months after the intervention. RESULTS Compared with the control group (1 month clinical rotation alone), students who were also exposed to the CD-ROM 20-case miniseries had significant improvements in auscultation skills scores (P < .05), but not knowledge. Additional months of clerkship, comprehensive CD-ROM cases, and follow-up seminars increased auscultation knowledge beyond the miniseries alone (P < .05), but did not further improve auscultation skills. Students' auscultation knowledge diminished one year after the intervention, but auscultation skills did not. CONCLUSION In addition to the standard curriculum of ward and conference teaching, portable multimedia tools may help improve quality of physical examination skills. PMID:11722691

  1. Using a multimedia tool to improve cardiac auscultation knowledge and skills.

    PubMed

    Stern, D T; Mangrulkar, R S; Gruppen, L D; Lang, A L; Grum, C M; Judge, R D

    2001-11-01

    Today's medical school graduates have significant deficits in physical examination skills. Medical educators have been searching for methods to effectively teach and maintain these skills in students. The objective of this study was to determine if an auscultation curriculum centered on a portable multimedia CD-ROM was effective in producing and maintaining significant gains in cardiac auscultatory skills. Controlled cohort study. All 168 third-year medical students at 1 medical school in an academic medical center. Students were tested before and after exposure to 1 or more elements of the auscultation curriculum: teaching on ward/clinic rotations, CD-ROM comprehensive cases with follow-up seminars, and a CD-ROM 20-case miniseries. The primary outcome measures were student performance on a 10-item test of auscultation skill (listening and identifying heart sound characteristics) and a 30-item test of auscultation knowledge (factual questions about auscultation). A subset of students was tested for attenuation effects 9 or 12 months after the intervention. Compared with the control group (1 month clinical rotation alone), students who were also exposed to the CD-ROM 20-case miniseries had significant improvements in auscultation skills scores (P < .05), but not knowledge. Additional months of clerkship, comprehensive CD-ROM cases, and follow-up seminars increased auscultation knowledge beyond the miniseries alone (P < .05), but did not further improve auscultation skills. Students' auscultation knowledge diminished one year after the intervention, but auscultation skills did not. In addition to the standard curriculum of ward and conference teaching, portable multimedia tools may help improve quality of physical examination skills.

  2. Vision-based measurement for rotational speed by improving Lucas-Kanade template tracking algorithm.

    PubMed

    Guo, Jie; Zhu, Chang'an; Lu, Siliang; Zhang, Dashan; Zhang, Chunyu

    2016-09-01

    Rotational angle and speed are important parameters for condition monitoring and fault diagnosis of rotating machineries, and their measurement is useful in precision machining and early warning of faults. In this study, a novel vision-based measurement algorithm is proposed to complete this task. A high-speed camera is first used to capture the video of the rotational object. To extract the rotational angle, the template-based Lucas-Kanade algorithm is introduced to complete motion tracking by aligning the template image in the video sequence. Given the special case of nonplanar surface of the cylinder object, a nonlinear transformation is designed for modeling the rotation tracking. In spite of the unconventional and complex form, the transformation can realize angle extraction concisely with only one parameter. A simulation is then conducted to verify the tracking effect, and a practical tracking strategy is further proposed to track consecutively the video sequence. Based on the proposed algorithm, instantaneous rotational speed (IRS) can be measured accurately and efficiently. Finally, the effectiveness of the proposed algorithm is verified on a brushless direct current motor test rig through the comparison with results obtained by the microphone. Experimental results demonstrate that the proposed algorithm can extract accurately rotational angles and can measure IRS with the advantage of noncontact and effectiveness.

  3. The sound field of a rotating dipole in a plug flow.

    PubMed

    Wang, Zhao-Huan; Belyaev, Ivan V; Zhang, Xiao-Zheng; Bi, Chuan-Xing; Faranosov, Georgy A; Dowell, Earl H

    2018-04-01

    An analytical far field solution for a rotating point dipole source in a plug flow is derived. The shear layer of the jet is modelled as an infinitely thin cylindrical vortex sheet and the far field integral is calculated by the stationary phase method. Four numerical tests are performed to validate the derived solution as well as to assess the effects of sound refraction from the shear layer. First, the calculated results using the derived formulations are compared with the known solution for a rotating dipole in a uniform flow to validate the present model in this fundamental test case. After that, the effects of sound refraction for different rotating dipole sources in the plug flow are assessed. Then the refraction effects on different frequency components of the signal at the observer position, as well as the effects of the motion of the source and of the type of source are considered. Finally, the effect of different sound speeds and densities outside and inside the plug flow is investigated. The solution obtained may be of particular interest for propeller and rotor noise measurements in open jet anechoic wind tunnels.

  4. Accuracy evaluation of a six-degree-of-freedom couch using cone beam CT and IsoCal phantom with an in-house algorithm.

    PubMed

    Zhang, Qinghui; Driewer, Joseph; Wang, Shuo; Li, Sicong; Zhu, Xiaofeng; Zheng, Dandan; Cao, Yijian; Zhang, Jiaju; Jamshidi, Abolghassem; Cox, Brett W; Knisely, Jonathan P S; Potters, Louis; Klein, Eric E

    2017-08-01

    The accuracy of a six degree of freedom (6DoF) couch was evaluated using a novel method. Cone beam CT (CBCT) images of a 3D phantom (IsoCal) were acquired with different, known combinations of couch pitch and roll angles. Pitch and roll angles between the maximum allowable values of 357 and 3 degrees were tested in one degree increments. A total of 49 combinations were tested at 0 degrees of yaw (couch rotation angle). The 3D positions of 16 tungsten carbide ball bearings (BBs), each 4 mm in diameter and arranged in a known geometry within the IsoCal phantom, were determined in the 49 image sets with in-house software. The BB positions at different rotation angles were determined using a rotation matrix from the original BB positions at zero pitch and roll angles. A linear least squares fit method estimated the rotation angles and differences between detected and nominal rotation angles were calculated. This study was conducted for the case with and without extra weight on the couch. Couch walk shifts for the system were investigated using eight combinations of rotation, roll and pitch. A total of 49 CBCT images with voxel sizes 0.5 × 0.5 × 1.0 mm 3 were taken for the case without extra weight on the couch. The 16 BBs were determined to evaluate the isocenter translation and rotation differences between the calculated and nominal couch values. Among all 49 calculations, the maximum rotation angle differences were 0.10 degrees for pitch, 0.15 degrees for roll and 0.09 degrees for yaw. The corresponding mean and standard deviation values were 0.028 ± 0.032, -0.043 ± 0.058, and -0.009 ± 0.033 degrees. The maximum translation differences were 0.3 mm in the left-right direction, 0.5 mm in the anterior-posterior direction and 0.4 mm in the superior-inferior direction. The mean values and corresponding standard deviations were 0.07 ± 0.12, -0.05 ± 0.25, and -0.12±0.14 mm for the planes described above. With an 80 kg phantom on the couch, the maximum translation shift was 0.69 mm. The couch walk translation shifts were less than 0.1 mm and rotation shifts were less than 0.1 degree. Errors of a new 6DoF couch were tested using CBCT images of a 3D phantom. The rotation errors were less than 0.3 degree and the translation errors were less than or equal to 0.8 mm in each direction. This level of accuracy is warranted for clinical radiotherapy utilization including stereotactic radiosurgery. © 2017 American Association of Physicists in Medicine.

  5. Kinematics of ACL and anterolateral ligament. Part II: anterolateral and anterior cruciate ligament reconstruction.

    PubMed

    Bonanzinga, T; Signorelli, C; Grassi, A; Lopomo, N; Jain, M; Mosca, M; Iacono, F; Marcacci, M; Zaffagnini, S

    2017-04-01

    To quantify the influence of Single-Bundle with Lateral Plasty and Double-Bundle reconstruction on static and dynamic laxity in combined ACL- and ALL-deficient knees. The study included 10 fresh-frozen human knees. The joints were analyzed in the following conditions: ACL + ALL resection, Single-Bundle with Lateral Plasty (SBLP) reconstruction, Double-Bundle (DB) reconstruction. Testing parameters were: anterior displacement at 30° and 90° of flexion (AP30, AP90) applying a manual maximum load; internal rotation at 30° and 90° of flexion (INT30, INT90) applying a 5 Nm torque and acceleration and internal rotation Pivot-Shift (PS) test. Kinematics was acquired by a navigation system. Paired Student's t test was conducted to assess statistical difference (P < 0.05). At both 30° and 90° of knee flexion, both SBLP and DB surgical techniques showed a significant reduction (P < 0.01) of anterior-posterior tibial displacement compared to the resection of ACL + ALL. At 30° on knee flexion it is the SBLP that allows the greatest reduction of internal rotational laxity when compared to DB reconstruction. Concerning the PS test, only SBPL procedure had a significant laxity decrease considering the acceleration reached by the joint when compared with the ACL + ALL state (P < 0.01). Clinical relevance of this study is that the internal rotation and PS test were more efficiently controlled by the SBLP technique than by the DB one at both 30° and 90° of flexion in case of ACL + ALL lesions.

  6. Normal modes of synchronous rotation

    NASA Astrophysics Data System (ADS)

    Varadi, Ferenc; Musotto, Susanna; Moore, William; Schubert, Gerald

    2005-07-01

    The dynamics of synchronous rotation and physical librations are revisited in order to establish a conceptually simple and general theoretical framework applicable to a variety of problems. Our motivation comes from disagreements between the results of numerical simulations and those of previous theoretical studies, and also because different theoretical studies disagree on basic features of the dynamics. We approach the problem by decomposing the orientation matrix of the body into perfectly synchronous rotation and deviation from the equilibrium state. The normal modes of the linearized equations are computed in the case of a circular satellite orbit, yielding both the periods and the eigenspaces of three librations. Libration in longitude decouples from the other two, vertical modes. There is a fast vertical mode with a period very close to the average rotational period. It corresponds to tilting the body around a horizontal axis while retaining nearly principal-axis rotation. In the inertial frame, this mode appears as nutation and free precession. The other vertical mode, a slow one, is the free wobble. The effects of the nodal precession of the orbit are investigated from the point of view of Cassini states. We test our theory using numerical simulations of the full equations of the dynamics and discuss the disagreements among our study and previous ones. The numerical simulations also reveal that in the case of eccentric orbits large departures from principal-axis rotation are possible due to a resonance between free precession and wobble. We also revisit the history of the Moon's rotational state and show that it switched from one Cassini state to another when it was at 46.2 Earth radii. This number disagrees with the value 34.2 derived in a previous study.

  7. Mental rotation of tactile stimuli: using directional haptic cues in mobile devices.

    PubMed

    Gleeson, Brian T; Provancher, William R

    2013-01-01

    Haptic interfaces have the potential to enrich users' interactions with mobile devices and convey information without burdening the user's visual or auditory attention. Haptic stimuli with directional content, for example, navigational cues, may be difficult to use in handheld applications; the user's hand, where the cues are delivered, may not be aligned with the world, where the cues are to be interpreted. In such a case, the user would be required to mentally transform the stimuli between different reference frames. We examine the mental rotation of directional haptic stimuli in three experiments, investigating: 1) users' intuitive interpretation of rotated stimuli, 2) mental rotation of haptic stimuli about a single axis, and 3) rotation about multiple axes and the effects of specific hand poses and joint rotations. We conclude that directional haptic stimuli are suitable for use in mobile applications, although users do not naturally interpret rotated stimuli in any one universal way. We find evidence of cognitive processes involving the rotation of analog, spatial representations and discuss how our results fit into the larger body of mental rotation research. For small angles (e.g., less than 40 degree), these mental rotations come at little cost, but rotations with larger misalignment angles impact user performance. When considering the design of a handheld haptic device, our results indicate that hand pose must be carefully considered, as certain poses increase the difficulty of stimulus interpretation. Generally, all tested joint rotations impact task difficulty, but finger flexion and wrist rotation interact to greatly increase the cost of stimulus interpretation; such hand poses should be avoided when designing a haptic interface.

  8. Trunk-rotation flexibility in collegiate softball players with or without a history of shoulder or elbow injury.

    PubMed

    Aragon, Veronica J; Oyama, Sakiko; Oliaro, Scott M; Padua, Darin A; Myers, Joseph B

    2012-01-01

    Throwing is a whole-body motion that requires the transfer of momentum from the lower extremity to the upper extremity via the trunk. No research to date examines the association between a history of shoulder or elbow injury and trunk flexibility in overhead athletes. To determine if injury history and trunk-rotation flexibility are associated and to compare trunk-rotation flexibility measured using 3 clinical tests: half-kneeling rotation test with the bar in the back, half-kneeling rotation test with the bar in the front, and seated rotation test in softball position players with or without a history of shoulder or elbow injury. Cross-sectional design. University softball facilities. Sixty-five female National Collegiate Athletic Association Division I softball position players. Trunk-rotation flexibility was measured with 3 clinical tests. Recent injury history was obtained using a questionnaire and verified by the certified athletic trainer. Binomial regression models were used to determine if injury history was associated with flexibility categories (high, normal, or limited tertiles) for each of the 6 (3 tests × 2 directions) trunk-rotation flexibility measures. Trunk-rotation flexibility measures from 3 clinical tests were compared between participants with and without a history of shoulder or elbow injury using analysis-of-variance models. When measured using the half-kneeling rotation test with the bar in the back and the seated rotation test, injury history and forward trunk-rotation flexibility were associated. However, no mean group differences were seen in trunk-rotation flexibility between participants with and without a history of shoulder or elbow injury. Limited forward trunk-rotation flexibility may be a risk factor for shoulder or elbow injuries. However, further study is needed to confirm the study finding.

  9. Errors of car wheels rotation rate measurement using roller follower on test benches

    NASA Astrophysics Data System (ADS)

    Potapov, A. S.; Svirbutovich, O. A.; Krivtsov, S. N.

    2018-03-01

    The article deals with rotation rate measurement errors, which depend on the motor vehicle rate, on the roller, test benches. Monitoring of the vehicle performance under operating conditions is performed on roller test benches. Roller test benches are not flawless. They have some drawbacks affecting the accuracy of vehicle performance monitoring. Increase in basic velocity of the vehicle requires increase in accuracy of wheel rotation rate monitoring. It determines the degree of accuracy of mode identification for a wheel of the tested vehicle. To ensure measurement accuracy for rotation velocity of rollers is not an issue. The problem arises when measuring rotation velocity of a car wheel. The higher the rotation velocity of the wheel is, the lower the accuracy of measurement is. At present, wheel rotation frequency monitoring on roller test benches is carried out by following-up systems. Their sensors are rollers following wheel rotation. The rollers of the system are not kinematically linked to supporting rollers of the test bench. The roller follower is forced against the wheels of the tested vehicle by means of a spring-lever mechanism. Experience of the test bench equipment operation has shown that measurement accuracy is satisfactory at small rates of vehicles diagnosed on roller test benches. With a rising diagnostics rate, rotation velocity measurement errors occur in both braking and pulling modes because a roller spins about a tire tread. The paper shows oscillograms of changes in wheel rotation velocity and rotation velocity measurement system’s signals when testing a vehicle on roller test benches at specified rates.

  10. A Comparison Study of Second-Order Screening Designs and Their Extension

    DTIC Science & Technology

    2013-12-01

    H2 97 V. Nonlinear Screening Designs for Defense Testing: An Overview and Case Study 5.1 Introduction “Necessity is the Mother of Invention.” Plato is...involved concepts like design resolution, minimum aber- ration , power, the number of clear (non-confounded) effects, concepts like rotatability

  11. Optical Angular Motion Sensor

    DTIC Science & Technology

    1975-04-01

    wedge at 10 Hz Background Radiation Completed Input Power Partially Transients, ripple and reverse Completed polarity power tests not per- formed...cases, indicating that the ACC was functioning properly. The changes seen were attributed to wedge angles and birefringent effects in the attenuators...noise for testing and is not within the specified value. 9.5.2 Method 2 A counter-rotating wedge of 15 arc minutes total deflection was used to measure

  12. Foam on Tile Impact Modeling for the STS-107 Investigation

    NASA Technical Reports Server (NTRS)

    Stellingwerf, R. F.; Robinson, J. H.; Richardson, S.; Evans, S. W.; Stallworth, R.; Hovater, M.

    2004-01-01

    Following the breakup of the Space Shuttle Columbia during reentry a NASA/Contractor investigation team was formed to examine the probable damage inflicted on Orbiter Thermal Protection System elements by impact of External Tank insulating foam projectiles. The authors formed a working subgroup within the larger team to apply the Smooth Particle Hydrodynamics code SPHC to the damage estimation problem. Numerical models of the Orbiter's tiles and of the Tank's foam were constructed and used as inputs into the code. Material properties needed to properly model the tiles and foam were obtained from other working subgroups who performed tests on these items for this purpose. Two- and three-dimensional models of the tiles were constructed, including the glass outer layer, the main body of LI-900 insulation, the densified lower layer of LI-900, the Nomex felt mounting layer, and the Aluminum 2024 vehicle skin. A model for the BX-250 foam including porous compression, elastic rebound, and surface erosion was developed. Code results for the tile damage and foam behavior were extensively validated through comparison with Southwest Research Institute foam-on-tile impact experiments carried out in 1999. These tests involved small projectiles striking individual tiles and small tile arrays. Following code and model validation we simulated impacts of larger foam projectiles on the examples of tile systems used on the Orbiter. Results for impacts on the main landing gear door are presented in this paper, including effects of impacts at several angles, and of rapidly rotating projectiles. General results suggest that foam impacts on tiles at about 500 mph could cause appreciable damage if the impact angle is greater than about 20 degrees. Some variations of the foam properties, such as increased brittleness or increased density could increase damage in some cases. Rotation up to 17 rps failed to increase the damage for the two cases considered. This does not rule out other cases in which the rotational energy might lead to an increase in tile damage, but suggests that in most cases rotation will not be an important factor.

  13. Separating "Rotators" from "Nonrotators" in the Mental Rotations Test: A Multigroup Latent Class Analysis

    ERIC Educational Resources Information Center

    Geiser, Christian; Lehmann, Wolfgang; Eid, Michael

    2006-01-01

    Items of mental rotation tests can not only be solved by mental rotation but also by other solution strategies. A multigroup latent class analysis of 24 items of the Mental Rotations Test (MRT) was conducted in a sample of 1,695 German pupils and students to find out how many solution strategies can be identified for the items of this test. The…

  14. The impact of manual rotation of the occiput posterior position on spontaneous vaginal delivery rate: study protocol for a randomized clinical trial (RMOS).

    PubMed

    Verhaeghe, C; Parot-Schinkel, E; Bouet, P E; Madzou, S; Biquard, F; Gillard, P; Descamps, P; Legendre, G

    2018-02-14

    The frequency of posterior presentations (occiput of the fetus towards the sacrum of the mother) in labor is approximately 20% and, of this, 5% remain posterior until the end of labor. These posterior presentations are associated with higher rates of cesarean section and instrumental delivery. Manual rotation of a posterior position in order to rotate the fetus to an anterior position has been proposed in order to reduce the rate of instrumental fetal delivery. No randomized study has compared the efficacy of this procedure to expectant management. We therefore propose a monocentric, interventional, randomized, prospective study to show the superiority of vaginal delivery rates using the manual rotation of the posterior position at full dilation over expectant management. Ultrasound imaging of the presentation will be performed at full dilation on all the singleton pregnancies for which a clinical suspicion of a posterior position was raised at more than 37 weeks' gestation (WG). In the event of an ultrasound confirming a posterior position, the patient will be randomized into an experimental group (manual rotation) or a control group (expectative management with no rotation). For a power of 90% and the hypothesis that vaginal deliveries will increase by 20%, (10% of patients lost to follow-up) 238 patients will need to be included in the study. The primary endpoint will be the rate of spontaneous vaginal deliveries (expected rate without rotation: 60%). The secondary endpoints will be the rate of fetal extractions (cesarean or instrumental) and the maternal and fetal morbidity and mortality rates. The intent-to-treat study will be conducted over 24 months. Recruitment started in February 2017. To achieve the primary objective, we will perform a test comparing the number of spontaneous vaginal deliveries in the two groups using Pearson's chi-squared test (provided that the conditions for using this test are satisfactory in terms of numbers). In the event that this test cannot be performed, we will use Fisher's exact test. Given that the efficacy of manual rotation has not been proven with a high level of evidence, the practice of this technique is not systematically recommended by scholarly societies and is, therefore, rarely performed by obstetric gynecologists. If our hypothesis regarding the superiority of manual rotation is confirmed, our study will help change delivery practices in cases of posterior fetal position. An increase in the rates of vaginal delivery will help decrease the short- and long-term rates of morbidity and mortality following cesarean section. Manual rotation is a simple and effective method with a success rate of almost 90%. Several preliminary studies have shown that manual rotation is associated with reduced rates for fetal extraction and maternal complications: Shaffer has shown that the cesarean section rate is lower in patients for whom a manual rotation is performed successfully (2%) with a 9% rate of cesarean sections when manual rotation is performed versus 41% when it is not performed. Le Ray has shown that manual rotation significantly reduces vaginal delivery rates via fetal extraction (23.2% vs 38.7%, p < 0.01). However, manual rotation is not systematically performed due to the absence of proof of its efficacy in retrospective studies and quasi-experimental before/after studies. ClinicalTrials.gov, Identifier: NCT03009435 . Registered on 30 December 2016.

  15. Effects of prolonged acceleration with or without clinostat rotation on seedlings of Arabidopsis thaliana (L.) Heynh

    NASA Technical Reports Server (NTRS)

    Brown, A. H.; Dahl, A. O.; Loercher, L.

    1974-01-01

    Three 21-day tests of the effects of chronic centrifugation were carried out on populations of Arabidopsis thaliana. In addition to 1 g the resultant g-forces tested were: 2,4,6,8,16, and 20 g. Observed end points included gross morphological characters such as size of plant organs and, at the other extreme, features of sub-cellular structure and ultrastructure. Plants were grown on banks of clinostats. The acceleration vector was directed either parallel with the plants' axes or transverse to the axes. Plant responses to chronic axial acceleration and to transverse acceleration with clinostated plants were determined. From the data obtained it was possible in some cases: (1) to determine the g-functions of specific plant developmental characters; (2) to extrapolate those functions to the hypothetical value at zero g in order to predict (tentatively) the morphology of a plant grown in space, (3) to describe morphological effects of clinostat rotation, (4) to determine which of those effects was influenced by the prevailing g-force, and (5) to put to direct test the assumption that clinostat rotation nullifies or compensates for the influence of gravity.

  16. Flexible robot control: Modeling and experiments

    NASA Technical Reports Server (NTRS)

    Oppenheim, Irving J.; Shimoyama, Isao

    1989-01-01

    Described here is a model and its use in experimental studies of flexible manipulators. The analytical model uses the equivalent of Rayleigh's method to approximate the displaced shape of a flexible link as the static elastic displacement which would occur under end rotations as applied at the joints. The generalized coordinates are thereby expressly compatible with joint motions and rotations in serial link manipulators, because the amplitude variables are simply the end rotations between the flexible link and the chord connecting the end points. The equations for the system dynamics are quite simple and can readily be formulated for the multi-link, three-dimensional case. When the flexible links possess mass and (polar moment of) inertia which are small compared to the concentrated mass and inertia at the joints, the analytical model is exact and displays the additional advantage of reduction in system dimension for the governing equations. Four series of pilot tests have been completed. Studies on a planar single-link system were conducted at Carnegie-Mellon University, and tests conducted at Toshiba Corporation on a planar two-link system were then incorporated into the study. A single link system under three-dimensional motion, displaying biaxial flexure, was then tested at Carnegie-Mellon.

  17. In Vivo Shoulder Function After Surgical Repair of a Torn Rotator Cuff

    PubMed Central

    Bey, Michael J.; Peltz, Cathryn D.; Ciarelli, Kristin; Kline, Stephanie K.; Divine, George W.; van Holsbeeck, Marnix; Muh, Stephanie; Kolowich, Patricia A.; Lock, Terrence R.; Moutzouros, Vasilios

    2015-01-01

    Background Surgical repair of a torn rotator cuff is based on the belief that repairing the tear is necessary to restore normal glenohumeral joint (GHJ) mechanics and achieve a satisfactory clinical outcome. Hypothesis Dynamic joint function is not completely restored by rotator cuff repair, thus compromising shoulder function and potentially leading to long-term disability. Study Design Controlled laboratory study and Case series; Level of evidence, 4. Methods Twenty-one rotator cuff patients and 35 control participants enrolled in the study. Biplane radiographic images were acquired bilaterally from each patient during coronal-plane abduction. Rotator cuff patients were tested at 3, 12, and 24 months after repair of a supraspinatus tendon tear. Control participants were tested once. Glenohumeral joint kinematics and joint contact patterns were accurately determined from the biplane radiographic images. Isometric shoulder strength and patient-reported outcomes were measured at each time point. Ultrasound imaging assessed rotator cuff integrity at 24 months after surgery. Results Twenty of 21 rotator cuff repairs appeared intact at 24 months after surgery. The humerus of the patients’ repaired shoulder was positioned more superiorly on the glenoid than both the patients’ contralateral shoulder and the dominant shoulder of control participants. Patient-reported outcomes improved significantly over time. Shoulder strength also increased over time, although strength deficits persisted at 24 months for most patients. Changes over time in GHJ mechanics were not detected for either the rotator cuff patients’ repaired or contralateral shoulders. Clinical outcome was associated with shoulder strength but not GHJ mechanics. Conclusion Surgical repair of an isolated supraspinatus tear may be sufficient to keep the torn rotator cuff intact and achieve satisfactory patient-reported outcomes, but GHJ mechanics and shoulder strength are not fully restored with current repair techniques. Clinical Relevance The study suggests that current surgical repair techniques may be effective for reducing pain but have not yet been optimized for restoring long-term shoulder function. PMID:21737834

  18. Quantum state preparation of homonuclear molecular ions enabled via a cold buffer gas: An ab initio study for the H2+ and the D2+ case

    NASA Astrophysics Data System (ADS)

    Schiller, S.; Kortunov, I.; Hernández Vera, M.; Gianturco, F.; da Silva, H.

    2017-04-01

    Precision vibrational spectroscopy of the molecular hydrogen ions is of significant interest for determining fundamental constants, for searching for new forces, and for testing quantum electrodynamics calculations. Future experiments can profit from the ability of preparing molecular hydrogen ions at ultralow kinetic energy and in preselected internal states, with respect to vibration, rotation, and spin degrees of freedom. For the homonuclear ions (H2+ , D2+ ), direct laser cooling of the rotational degree of freedom is not feasible. We show by quantum calculations that rotational cooling by cold He buffer gas is an effective approach. For this purpose we have computed the energy-dependent cross sections for rotationally elastic and inelastic collisions, h2+ (v =0 ,N ) +He → h2+ (v =0 ,N') +He (where h =H ,D ) , using ab initio coupled-channel calculations. We find that rotational cooling to the lowest rotational state is possible within tens of seconds under experimentally realistic conditions. We furthermore describe possible protocols for the preparation of a single quantum state, where also the spin state is well defined.

  19. Subgrid-scale models for large-eddy simulation of rotating turbulent channel flows

    NASA Astrophysics Data System (ADS)

    Silvis, Maurits H.; Bae, Hyunji Jane; Trias, F. Xavier; Abkar, Mahdi; Moin, Parviz; Verstappen, Roel

    2017-11-01

    We aim to design subgrid-scale models for large-eddy simulation of rotating turbulent flows. Rotating turbulent flows form a challenging test case for large-eddy simulation due to the presence of the Coriolis force. The Coriolis force conserves the total kinetic energy while transporting it from small to large scales of motion, leading to the formation of large-scale anisotropic flow structures. The Coriolis force may also cause partial flow laminarization and the occurrence of turbulent bursts. Many subgrid-scale models for large-eddy simulation are, however, primarily designed to parametrize the dissipative nature of turbulent flows, ignoring the specific characteristics of transport processes. We, therefore, propose a new subgrid-scale model that, in addition to the usual dissipative eddy viscosity term, contains a nondissipative nonlinear model term designed to capture transport processes, such as those due to rotation. We show that the addition of this nonlinear model term leads to improved predictions of the energy spectra of rotating homogeneous isotropic turbulence as well as of the Reynolds stress anisotropy in spanwise-rotating plane-channel flows. This work is financed by the Netherlands Organisation for Scientific Research (NWO) under Project Number 613.001.212.

  20. A plasma rotation control scheme for NSTX and NSTX-U

    NASA Astrophysics Data System (ADS)

    Goumiri, Imene

    2016-10-01

    Plasma rotation has been proven to play a key role in stabilizing large scale instabilities and improving plasma confinement by suppressing micro-turbulence. A model-based feedback system which controls the plasma rotation profile on the National Spherical Torus Experiment (NSTX) and its upgrade (NSTX-U) is presented. The first part of this work uses experimental measurements from NSTX as a starting point and models the control of plasma rotation using two different types of actuation: momentum from injected neutral beams and neoclassical toroidal viscosity generated by three-dimensional applied magnetic fields. Whether based on the data-driven model for NSTX or purely predictive modeling for NSTX-U, a reduced order model based feedback controller was designed. Predictive simulations using the TRANSP plasma transport code with the actuator input determined by the controller (controller-in-the-loop) show that the controller drives the plasma's rotation to the desired profiles in less than 100 ms given practical constraints on the actuators and the available real-time rotation measurements. This is the first time that TRANSP has been used as a plasma in simulator in a closed feedback loop test. Another approach to control simultaneously the toroidal rotation profile as well as βN is then shown for NSTX-U. For this case, the neutral beams (actuators) have been augmented in the modeling to match the upgrade version which spread the injection throughout the edge of the plasma. Control robustness in stability and performance has then been tested and used to predict the limits of the resulting controllers when the energy confinement time (τE) and the momentum diffusivity coefficient (χϕ) vary.

  1. Trunk-Rotation Flexibility in Collegiate Softball Players With or Without a History of Shoulder or Elbow Injury

    PubMed Central

    Aragon, Veronica J.; Oyama, Sakiko; Oliaro, Scott M.; Padua, Darin A.; Myers, Joseph B.

    2012-01-01

    Context: Throwing is a whole-body motion that requires the transfer of momentum from the lower extremity to the upper extremity via the trunk. No research to date examines the association between a history of shoulder or elbow injury and trunk flexibility in overhead athletes. Objective: To determine if injury history and trunk-rotation flexibility are associated and to compare trunk-rotation flexibility measured using 3 clinical tests: half-kneeling rotation test with the bar in the back, half-kneeling rotation test with the bar in the front, and seated rotation test in softball position players with or without a history of shoulder or elbow injury. Design: Cross-sectional design. Setting: University softball facilities. Patients or Other Participants: Sixty-five female National Collegiate Athletic Association Division I softball position players. Intervention(s): Trunk-rotation flexibility was measured with 3 clinical tests. Recent injury history was obtained using a questionnaire and verified by the certified athletic trainer. Main Outcome Measure(s): Binomial regression models were used to determine if injury history was associated with flexibility categories (high, normal, or limited tertiles) for each of the 6 (3 tests × 2 directions) trunk-rotation flexibility measures. Trunk-rotation flexibility measures from 3 clinical tests were compared between participants with and without a history of shoulder or elbow injury using analysis-of-variance models. Results: When measured using the half-kneeling rotation test with the bar in the back and the seated rotation test, injury history and forward trunk-rotation flexibility were associated. However, no mean group differences were seen in trunk-rotation flexibility between participants with and without a history of shoulder or elbow injury. Conclusions: Limited forward trunk-rotation flexibility may be a risk factor for shoulder or elbow injuries. However, further study is needed to confirm the study finding. PMID:23068587

  2. Distorted turbulence submitted to frame rotation: RDT and LES results

    NASA Technical Reports Server (NTRS)

    Godeferd, Fabien S.

    1995-01-01

    The objective of this effort is to carry the analysis of Lee et al. (1990) to the case of shear with rotation. We apply the RDT approximation to turbulence submitted to frame rotation for the case of a uniformly sheared flow and compare its mean statistics to results of high resolution DNS of a rotating plane channel flow. In the latter, the mean velocity profile is modified by the Coriolis force, and accordingly, different regions in the channel can be identified. The properties of the plane pure strain turbulence submitted to frame rotation are, in addition, investigated in spectral space, which shows the usefulness of the spectral RDT approach. This latter case is investigated here. Among the general class of quadratic flows, this case does not follow the same stability properties as the others since the related mean vorticity is zero.

  3. Containment of composite fan blades

    NASA Technical Reports Server (NTRS)

    Stotler, C. L.; Coppa, A. P.

    1979-01-01

    A lightweight containment was developed for turbofan engine fan blades. Subscale ballistic-type tests were first run on a number of concepts. The most promising configuration was selected and further evaluated by larger scale tests in a rotating test rig. Weight savings made possible by the use of this new containment system were determined and extrapolated to a CF6-size engine. An analytical technique was also developed to predict the released blades motion when involved in the blade/casing interaction process. Initial checkout of this procedure was accomplished using several of the tests run during the program.

  4. Pulley lesions in rotator cuff tears: prevalence, etiology, and concomitant pathologies.

    PubMed

    Hawi, Nael; Liodakis, Emmanouil; Garving, Christina; Habermeyer, Peter; Tauber, Mark

    2017-08-01

    This study aimed to demonstrate the prevalence of lesions in the biceps pulley complex in a representative, consecutive series of rotator cuff tears and rotator cuff interval treatments. We also analyzed associated tear pattern of rotator cuff injuries and superior labrum anterior-posterior (SLAP) lesions. We evaluated the relationships of these lesions to traumatic genesis and the prevalence of pulley lesions in revision cases. This retrospective study analyzed all pre- and intra-operative documentation on arthroscopic rotator cuff reconstructions and isolated pulley lesion treatments performed by a single surgeon over 2 consecutive years. According to Habermeyer et al., we classified cases into four groups, based on the presence of additional or related complete or partial rotator cuff tears, SLAP lesions, trauma, and primary or revision surgery. Among 382 patients with rotator cuff tears, 345 (90.3%) had an injured pulley system; 151 (43.8%) had partial tears of the rotator cuff; out of these, 106 (30.6%) were articular-sided. All of these articular-sided partial tears showed extension into the pulley complex. In 154 cases (44.6%), history of shoulder trauma was associated with the beginning of symptoms. In addition, concomitant SLAP lesions occurred in 25-62% of pulley lesions, correlating with the severity of pulley lesions. Among the 345 cases, there have been 32 (9.3%) revision cases where a pulley lesion was intra-operatively identified and addressed. Pulley complex lesions are present in 90.3% of surgically treated rotator cuff lesions, particularly in articular-sided injuries. In addition, we found a significant relationship between the incidence of SLAP lesions and the severity of pulley lesions. It seems reasonable to assume an important role of pulley system injuries in the pathogenesis of rotator cuff lesions.

  5. Diagnostic accuracy of the gravity stress test and clinical signs in cases of isolated supination-external rotation-type lateral malleolar fractures.

    PubMed

    Nortunen, S; Flinkkilä, T; Lantto, I; Kortekangas, T; Niinimäki, J; Ohtonen, P; Pakarinen, H

    2015-08-01

    We prospectively assessed the diagnostic accuracy of the gravity stress test and clinical findings to evaluate the stability of the ankle mortise in patients with supination-external rotation-type fractures of the lateral malleolus without widening of the medial clear space. The cohort included 79 patients with a mean age of 44 years (16 to 82). Two surgeons assessed medial tenderness, swelling and ecchymosis and performed the external rotation (ER) stress test (a reference standard). A diagnostic radiographer performed the gravity stress test. For the gravity stress test, the positive likelihood ratio (LR) was 5.80 with a 95% confidence interval (CI) of 2.75 to 12.27, and the negative LR was 0.15 (95% CI 0.07 to 0.35), suggesting a moderate change from the pre-test probability. Medial tenderness, both alone and in combination with swelling and/or ecchymosis, indicated a small change (positive LR, 2.74 to 3.25; negative LR, 0.38 to 0.47), whereas swelling and ecchymosis indicated only minimal changes (positive LR, 1.41 to 1.65; negative LR, 0.38 to 0.47). In conclusion, when gravity stress test results are in agreement with clinical findings, the result is likely to predict stability of the ankle mortise with an accuracy equivalent to ER stress test results. When clinical examination suggests a medial-side injury, however, the gravity stress test may give a false negative result. ©2015 The British Editorial Society of Bone & Joint Surgery.

  6. Laboratory and field testing of commercial rotational seismometers

    USGS Publications Warehouse

    Nigbor, R.L.; Evans, J.R.; Hutt, C.R.

    2009-01-01

    There are a small number of commercially available sensors to measure rotational motion in the frequency and amplitude ranges appropriate for earthquake motions on the ground and in structures. However, the performance of these rotational seismometers has not been rigorously and independently tested and characterized for earthquake monitoring purposes as is done for translational strong- and weak-motion seismometers. Quantities such as sensitivity, frequency response, resolution, and linearity are needed for the understanding of recorded rotational data. To address this need, we, with assistance from colleagues in the United States and Taiwan, have been developing performance test methodologies and equipment for rotational seismometers. In this article the performance testing methodologies are applied to samples of a commonly used commercial rotational seismometer, the eentec model R-1. Several examples were obtained for various test sequences in 2006, 2007, and 2008. Performance testing of these sensors consisted of measuring: (1) sensitivity and frequency response; (2) clip level; (3) self noise and resolution; and (4) cross-axis sensitivity, both rotational and translational. These sensor-specific results will assist in understanding the performance envelope of the R-1 rotational seismometer, and the test methodologies can be applied to other rotational seismometers.

  7. Impact of rotation angle on crawling and non-crawling 9-month-old infants' mental rotation ability.

    PubMed

    Gerhard, Theresa M; Schwarzer, Gudrun

    2018-06-01

    The current study investigated whether 9-month-old infants' mental rotation performance was influenced by the magnitude of the angle of object rotation and their crawling ability. A total of 76 infants were tested; of these infants, 39 had been crawling for an average of 9.0 weeks. Infants were habituated to a video of a simplified Shepard-Metzler object (Shepard & Metzler, 1971), always rotating forward through a 180° angle around the horizontal axis of the object. After habituation, in two different test conditions, infants were presented with test videos of the same object rotating farther forward through a previously unseen 90° angle and with a test video of its mirror image. The two test conditions differed in the magnitude of the gap between the end of the habituation rotations and the beginning of the test rotations. The gaps were 0° and 54°. The results revealed that the mental rotation performance was influenced by the magnitude of the gaps only for the crawling infants. Their response showed significant transition from a preference for the mirror object rotations toward a preference for the familiar habituation object rotations. Thus, the results provide first evidence that it is easier for 9-month-old crawling infants to mentally rotate an object along a small angle compared with a large one. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Trajectory optimization for dynamic couch rotation during volumetric modulated arc radiotherapy

    NASA Astrophysics Data System (ADS)

    Smyth, Gregory; Bamber, Jeffrey C.; Evans, Philip M.; Bedford, James L.

    2013-11-01

    Non-coplanar radiation beams are often used in three-dimensional conformal and intensity modulated radiotherapy to reduce dose to organs at risk (OAR) by geometric avoidance. In volumetric modulated arc radiotherapy (VMAT) non-coplanar geometries are generally achieved by applying patient couch rotations to single or multiple full or partial arcs. This paper presents a trajectory optimization method for a non-coplanar technique, dynamic couch rotation during VMAT (DCR-VMAT), which combines ray tracing with a graph search algorithm. Four clinical test cases (partial breast, brain, prostate only, and prostate and pelvic nodes) were used to evaluate the potential OAR sparing for trajectory-optimized DCR-VMAT plans, compared with standard coplanar VMAT. In each case, ray tracing was performed and a cost map reflecting the number of OAR voxels intersected for each potential source position was generated. The least-cost path through the cost map, corresponding to an optimal DCR-VMAT trajectory, was determined using Dijkstra’s algorithm. Results show that trajectory optimization can reduce dose to specified OARs for plans otherwise comparable to conventional coplanar VMAT techniques. For the partial breast case, the mean heart dose was reduced by 53%. In the brain case, the maximum lens doses were reduced by 61% (left) and 77% (right) and the globes by 37% (left) and 40% (right). Bowel mean dose was reduced by 15% in the prostate only case. For the prostate and pelvic nodes case, the bowel V50 Gy and V60 Gy were reduced by 9% and 45% respectively. Future work will involve further development of the algorithm and assessment of its performance over a larger number of cases in site-specific cohorts.

  9. Operation Ivy. Project 8. 4. Report to the Scientific Director. High-resolution spectroscopy at Ivy compared with previous tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beck, C.A.

    1985-04-01

    The high-resolution ultraviolet and visible spectra of typical test nuclear detonations up to and including Operation Ivy were analyzed and compared. Topics studied include the types of atomc and molecular material observed (with calculations, in some cases, of the relative quantities involved), the ultraviolet cutoff, and rotational temperatures. Variation of these quantities with the radiochemical yield of the bomb is indicated.

  10. Flow measurement behind a pair of vertical-axis wind turbines

    NASA Astrophysics Data System (ADS)

    Parker, Colin M.; Hummels, Raymond; Leftwich, Megan C.

    2017-11-01

    The wake from a pair of vertical-axis wind turbines (VAWTs) is measured using particle imaging velocimetry (PIV). The VAWT models are mounted in a low-speed wind tunnel and driven using a motor control system. The rotation of the turbines is synced using a proportional controller that allows the turbine's rotational position to be set relative to each other. The rotation of the turbines is also synced with the PIV system for taking phase averaged results. The VAWTs are tested for both co- and counter-rotating cases over a range of relative phase offsets. Time averaged and phase averaged results are measured at the horizontal mid-plane in the near wake. The time-averaged results compare the bulk wake profiles from the pair of turbines. Phase averaged results look at the vortex interactions in the near wake of the turbines. By changing the phase relation between the turbines we can see the impact of the structure interactions in both the phase and time averaged results.

  11. Cognitive profile of patients with rotated drawing at copy or recall: a controlled group study.

    PubMed

    Molteni, Federica; Traficante, Debora; Ferri, Francesca; Isella, Valeria

    2014-03-01

    When copying or recalling a figure from memory, some patient with dementia or focal brain lesions may rotate the drawing through ±90° or 180°. We have tried to clarify the nature of this phenomenon by investigating the cognitive profile of 22 patients who rotated the copy of the Rey-Osterrieth Complex Figure and 27 who rotated (only) the recall, and two control groups of cases with the same neuropsychiatric diagnoses, but no misorientation deficit. Brain MRI and FDG-PET images were also analysed. Predictor of rotation at the copy versus rotation at the recall was visuospatial impairment as measured by the copy of the Rey Figure; predictors of rotation at the copy versus no rotation were, again, visuospatial deficits, in addition to an abnormal performance at the task of selective attention. No specific profile of cognitive impairment distinguished patients with and without rotation at the recall. Disproportionate temporo-parieto-occipital atrophy or hypometabolism were evident in cases with misorientation of the copy, while predominant frontal abnormalities were found in cases of rotated recall. Based on these findings, rotated drawing at the copy is interpreted as a dorsal visual stream deficit, whose occurrence is more probable when attentional control is impaired. Rotation at recall seems to have a distinct, more anterior, neural substrate, but its dysexecutive nature has yet to be demonstrated. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Convergence issues in domain decomposition parallel computation of hovering rotor

    NASA Astrophysics Data System (ADS)

    Xiao, Zhongyun; Liu, Gang; Mou, Bin; Jiang, Xiong

    2018-05-01

    Implicit LU-SGS time integration algorithm has been widely used in parallel computation in spite of its lack of information from adjacent domains. When applied to parallel computation of hovering rotor flows in a rotating frame, it brings about convergence issues. To remedy the problem, three LU factorization-based implicit schemes (consisting of LU-SGS, DP-LUR and HLU-SGS) are investigated comparatively. A test case of pure grid rotation is designed to verify these algorithms, which show that LU-SGS algorithm introduces errors on boundary cells. When partition boundaries are circumferential, errors arise in proportion to grid speed, accumulating along with the rotation, and leading to computational failure in the end. Meanwhile, DP-LUR and HLU-SGS methods show good convergence owing to boundary treatment which are desirable in domain decomposition parallel computations.

  13. Numerical simulations of bistable flows in precessing spheroidal shells

    NASA Astrophysics Data System (ADS)

    Vormann, J.; Hansen, U.

    2018-05-01

    Precession of the rotation axis is an often neglected mechanical driving mechanism for flows in planetary interiors, through viscous coupling at the boundaries and topographic forcing in non-spherical geometries. We investigate precession-driven flows in spheroidal shells over a wide range of parameters and test the results against theoretical predictions. For Ekman numbers down to 8.0 × 10-7, we see a good accordance with the work of Busse, who assumed the precession-driven flow to be dominated by a rigid rotation component that is tilted to the main rotation axis. The velocity fields show localized small-scale structures for lower Ekman numbers and clear signals of inertial waves for some parameters. For the case of moderate viscosity and strong deformation, we report the realization of multiple solutions at the same parameter combination, depending on the initial condition.

  14. Rotational Flap to Enhance Buccal Gingival Thickness and Implant Emergence Profile in the Esthetic Zone: Two Cases Reports

    PubMed Central

    AL-Juboori, Mohammed Jasim

    2017-01-01

    Objective: Many techniques have been developed to enhance the gingival thickness, gingival level and emergence profile around the implant in the esthetic zone. Introduction: In this study, a buccal rotational flap was used to improve the implant site in the esthetic zone and increase gingival tissue thickness. Methods: Two cases involved the use of a rotational flap during second-stage implant surgery, one case involved the use of a temporary crown with a healing abutment, and another case involved the use of a healing abutment. Result: The cases were followed up until the final crown was placed. The implant site was improved in 2 cases; the gingival thickness increased, the gingival level was enhanced and the emergence profile was developed. Conclusion: Many factors affect the results of a rotational flap; some factors are surgical, while others are prosthetic, biological and anatomical. PMID:28839477

  15. Keeping It in Three Dimensions: Measuring the Development of Mental Rotation in Children with the Rotated Colour Cube Test (RCCT)

    ERIC Educational Resources Information Center

    Lutke, Nikolay; Lange-Kuttner, Christiane

    2015-01-01

    This study introduces the new Rotated Colour Cube Test (RCCT) as a measure of object identification and mental rotation using single 3D colour cube images in a matching-to-sample procedure. One hundred 7- to 11-year-old children were tested with aligned or rotated cube models, distracters and targets. While different orientations of distracters…

  16. Effect of an external magnetic field on particle acceleration by a rotating black hole surrounded with quintessential energy

    NASA Astrophysics Data System (ADS)

    Shaymatov, Sanjar; Ahmedov, Bobomurat; Stuchlík, Zdeněk; Abdujabbarov, Ahmadjon

    We investigate particle motion and collisions in the vicinity of rotating black holes immersed in combined cosmological quintessential scalar field and external magnetic field. The quintessential dark-energy field governing the spacetime structure is characterized by the quintessential state parameter ωq ∈ (‑1; ‑1/3) characterizing its equation of state, and the quintessential field-intensity parameter c determining the static radius where the black hole attraction is just balanced by the quintessential repulsion. The magnetic field is assumed to be test field that is uniform close to the static radius, where the spacetime is nearly flat, being characterized by strength B there. Deformations of the test magnetic field in vicinity of the black hole, caused by the Ricci non-flat spacetime structure are determined. General expression of the center-of-mass energy of the colliding charged or uncharged particles near the black hole is given and discussed in several special cases. In the case of nonrotating black holes, we discuss collisions of two particles freely falling from vicinity of the static radius, or one such a particle colliding with charged particle revolving at the innermost stable circular orbit. In the case of rotating black holes, we discuss briefly particles falling in the equatorial plane and colliding in close vicinity of the black hole horizon, concentrating attention to the interplay of the effects of the quintessential field and the external magnetic field. We demonstrate that the ultra-high center-of-mass energy can be obtained for black holes placed in an external magnetic field for an infinitesimally small quintessential field-intensity parameter c; the center-of-mass energy decreases if the quintessential field-intensity parameter c increases.

  17. [Analysis of the influence of lower premolar rotation on TMJ stress distribution by finite element method].

    PubMed

    Zhang, Yuan; Wang, Mei-qing; Ling, Wei

    2005-10-01

    To evaluate the resultant differences of stress distribution in bilateral condyle when occlusal loads were changed with teeth rotation. A three-dimensional FEA model containing human TMJ and left lower second premolar was developed using commercial FEA software ANSYS. Lower second premolar was applied with ICO occlusal loading in the load case 1. According to the same upper dentition in the load case 2, lower premolar was applied with occlusal loading when it was rotated 30 degree counter-clockwise in Frankfort horizontal plane level. In this two load cases,the different stress distributions of the condyle was investigated. The stress distribution of loading side condyle had changed abnormally when premolar rotation was performed. It had showed more disorderly than ICO loading in load case 1. In load case 1 the maximum main stress and Von Mises stress values increased from medial pole to lateral pole. In load case 2,the stress values mainly decreased from medial pole to lateral pole, but along the path there were some parts with values-increasing. The stress values of bilateral condyle in load case 2 were lower than that in load case 1, especially for the stress values of the opposite condyle. The stress distribution of loading side condyle got in disorder resulting from rotation of unilateral lower premolar.

  18. Turbocharger

    DOEpatents

    Sun, Harold Huimin; Hanna, Dave; Zhang, Jizhong; Hu, Liangjun; Krivitzky, Eric M.; Larosiliere, Louis M.; Baines, Nicholas C.

    2013-08-27

    In one example, a turbocharger for an internal combustion engine is described. The turbocharger comprises a casing containing an impeller having a full blade coupled to a hub that rotates about an axis of rotation. The casing includes a bleed port and an injection port. The full blade includes a hub edge, a casing edge, and a first distribution of angles, each angle measured between the axis of rotation and a mean line at the hub edge at a meridional distance along the hub edge. The full blade includes a second distribution of angles, each angle measured between the axis of rotation and a mean line at the casing edge at a meridional distance along the casing edge. Further, various systems are described for affecting the aerodynamic properties of the compressor and turbine components in a way that may extend the operating range of the turbocharger.

  19. Hip Rotation Range of Motion in People With and Without Low Back Pain Who Participate in Rotation-Related Sports

    PubMed Central

    Van Dillen, Linda R.; Bloom, Nancy J.; Gombatto, Sara P.; Susco, Thomas M.

    2008-01-01

    Objective To examine whether passive hip rotation motion was different between people with and without low back pain (LBP) who regularly participate in sports that require repeated rotation of the trunk and hips. We hypothesized that people with LBP would have less total hip rotation motion and more asymmetry of motion between sides than people without LBP. Design Two group, case-control. Setting University-based musculoskeletal analysis laboratory. Participants Forty-eight subjects (35 males, 13 females; mean age: 26.56±7.44 years) who reported regular participation in a rotation-related sport participated. Two groups were compared; people with LBP (N=24) and people without LBP (N=24; NoLBP). Main outcome measures Data were collected on participant-related, LBP-related, sport-related and activity-related variables. Measures of passive hip rotation range of motion were obtained. The differences between the LBP and NoLBP groups were examined. Results People with and without a history of LBP were the same with regard to all participant-related, sport-related and activity-related variables. The LBP group had significantly less total rotation (P=.035) and more asymmetry of total rotation, right hip versus left hip, (P=.022) than the NoLBP group. Left total hip rotation was more limited than right total hip rotation in the LBP group (P=.004). There were no significant differences in left and right total hip rotation for the NoLBP group (P=.323). Conclusions Among people who participate in rotation-related sports, those with LBP had less overall passive hip rotation motion and more asymmetry of rotation between sides than people without LBP. These findings suggest that the specific directional demands imposed on the hip and trunk during regularly performed activities may be an important consideration in deciding which impairments may be most relevant to test and to consider in prevention and intervention strategies. PMID:19081817

  20. Clinical Assessment of Physical Examination Maneuvers for Rotator Cuff Lesions.

    PubMed

    Somerville, Lyndsay E; Willits, Kevin; Johnson, Andrew M; Litchfield, Robert; LeBel, Marie-Eve; Moro, Jaydeep; Bryant, Dianne

    2014-08-01

    Shoulder pain and disability pose a diagnostic challenge for clinicians owing to the numerous causes that exist. Unfortunately, the evidence in support of most clinical tests is weak or absent. To determine the diagnostic validity of physical examination maneuvers for rotator cuff lesions. Cohort study (diagnosis); Level of evidence, 1. Consecutive shoulder patients recruited for this study were referred to 2 tertiary orthopaedic clinics. A surgeon took a thorough history and indicated his or her certainty about each possible diagnosis. A clinician performed the physical examination for diagnoses where uncertainty remained. Arthroscopy was considered the reference standard for patients who underwent surgery, and MRI with arthrogram was considered the reference for patients who did not. The sensitivity, specificity, and likelihood ratios were calculated to investigate whether combinations of the top tests provided stronger predictions of the presence or absence of disease. There were 139 participants. None of the tests were highly sensitive for diagnosing rotator cuff tears or tendinosis. Tests for subscapularis tears were all highly specific. No optimal combination of tests improved the ability to correctly diagnose rotator cuff tears. Closer analysis revealed the internal rotation and lateral rotation lag sign did not improve the ability to diagnose subscapularis or supraspinatus tears, respectively, although the lateral rotation lag sign demonstrated a discriminatory ability for tear size. No test in isolation is sufficient to diagnose a patient with rotator cuff damage. A combination of tests improves the ability to diagnose damage to the rotator cuff. It is recommended that the internal rotation and lateral rotation lag signs be removed from the gamut of physical examination tests for supraspinatus and subscapularis tears. © 2014 The Author(s).

  1. Functional form for plasma velocity in a rapidly rotating tokamak discharge

    DOE PAGES

    Burrell, Keith H.; Chrystal, C. olin

    2014-07-25

    A recently developed technique using charge exchange spectroscopy determines the ion poloidal rotation in tokamak plasmas from the poloidal variation in the toroidal angular rotation speed. The basis for this technique is the functional form for the plasma velocity calculated from the equilibrium equations. The initial development of this technique utilized the functional form determined for conditions where the ion toroidal rotation speed is much smaller than the ion thermal speed. There are cases, however, where the toroidal rotation can be comparable to the ion thermal speed, especially for high atomic number impurities. Furthermore, the present paper extends the previousmore » analysis to this high rotation speed case and demonstrates how to extract the poloidal rotation speed from measurements of the toroidal angular rotation speed at two points on a flux surface.« less

  2. Traumatic anterior shoulder dislocation: a case study of nonoperative management in a mixed martial arts athlete.

    PubMed

    Sims, Kevin; Spina, Andreo

    2009-12-01

    To present an evidence-informed approach to the nonoperative management of a first-time, traumatic anterior shoulder dislocation. A 30-year-old mixed martial arts athlete, with no prior shoulder injuries, presented one day following a first-time, traumatic anterior shoulder dislocation. An eight-week, individualized, intensive, nonoperative rehabilitation program was immediately begun upon presentation. Management consisted of immobilization of the shoulder in external rotation and a progressive rehabilitation program aimed at restoring range of motion, strength of the dynamic stabilizers, and proprioception of the shoulder. Eight weeks post-dislocation the patient had regained full range of motion and strength compared to the unaffected limb and apprehension and relocation tests for instability were negative. This case illustrates successful management of a first-time, traumatic, anterior shoulder dislocation using immobilization in external rotation combined with an intensive rehabilitation program.

  3. Traumatic anterior shoulder dislocation: a case study of nonoperative management in a mixed martial arts athlete

    PubMed Central

    Sims, Kevin; Spina, Andreo

    2009-01-01

    Objective: To present an evidence-informed approach to the nonoperative management of a first-time, traumatic anterior shoulder dislocation. Clinical Features: A 30-year-old mixed martial arts athlete, with no prior shoulder injuries, presented one day following a first-time, traumatic anterior shoulder dislocation. An eight-week, individualized, intensive, nonoperative rehabilitation program was immediately begun upon presentation. Intervention and Outcome: Management consisted of immobilization of the shoulder in external rotation and a progressive rehabilitation program aimed at restoring range of motion, strength of the dynamic stabilizers, and proprioception of the shoulder. Eight weeks post-dislocation the patient had regained full range of motion and strength compared to the unaffected limb and apprehension and relocation tests for instability were negative. Conclusion: This case illustrates successful management of a first-time, traumatic, anterior shoulder dislocation using immobilization in external rotation combined with an intensive rehabilitation program. PMID:20037691

  4. Can CT-based patient-matched instrumentation achieve consistent rotational alignment in knee arthroplasty?

    PubMed

    Tibesku, C O; Innocenti, B; Wong, P; Salehi, A; Labey, L

    2012-02-01

    Long-term success of contemporary total knee replacements relies to a large extent on proper implant alignment. This study was undertaken to test whether specimen-matched cutting blocks based on computed axial tomography (CT) scans could provide accurate rotational alignment of the femoral component. CT scans of five fresh frozen full leg cadaver specimens, equipped with infrared reflective markers, were used to produce a specimen-matched femoral cutting block. Using those blocks, the bone cuts were made to implant a bi-compartmental femoral component. Rotational alignment of the components in the horizontal plane was determined using an optical measurement system and compared with all relevant rotational reference axes identified on the CT scans. Average rotational alignment for the bi-compartmental component in the horizontal plane was 1.9° (range 0°-6.3°; standard deviation 2.6°). One specimen that showed the highest deviation from the planned alignment also featured a completely degraded medial articular surface. The CT-based specimen-matched cutting blocks achieved good rotational alignment accuracy except for one specimen with badly damaged cartilage. In such cases, imaging techniques that visualize the cartilage layer might be more suitable to design cutting blocks, as they will provide a better fit and increased surface support.

  5. An acute care surgery rotation contributes significant general surgical operative volume to residency training compared with other rotations.

    PubMed

    Stanley, Matthew D; Davenport, Daniel L; Procter, Levi D; Perry, Jacob E; Kearney, Paul A; Bernard, Andrew C

    2011-03-01

    Surgical resident rotations on trauma services are criticized for little operative experience and heavy workloads. This has resulted in diminished interest in trauma surgery among surgical residents. Acute care surgery (ACS) combines trauma and emergency/elective general surgery, enhancing operative volume and balancing operative and nonoperative effort. We hypothesize that a mature ACS service provides significant operative experience. A retrospective review was performed of ACGME case logs of 14 graduates from a major, academic, Level I trauma center program during a 3-year period. Residency Review Committee index case volumes during the fourth and fifth years of postgraduate training (PGY-4 and PGY-5) ACS rotations were compared with other service rotations: in total and per resident week on service. Ten thousand six hundred fifty-four cases were analyzed for 14 graduates. Mean cases per resident was 432 ± 57 in PGY-4, 330 ± 40 in PGY-5, and 761 ± 67 for both years combined. Mean case volume on ACS for both years was 273 ± 44, which represented 35.8% (273 of 761) of the total experience and exceeded all other services. Residents averaged 8.9 cases per week on the ACS service, which exceeded all other services except private general surgery, gastrointestinal/minimally invasive surgery, and pediatric surgery rotations. Disproportionately more head/neck, small and large intestine, gastric, spleen, laparotomy, and hernia cases occurred on ACS than on other services. Residents gain a large operative experience on ACS. An ACS model is viable in training, provides valuable operative experience, and should not be considered a drain on resident effort. Valuable ACS rotation experiences as a resident may encourage graduates to pursue ACS as a career. Copyright © 2011 by Lippincott Williams & Wilkins

  6. Assessing Situational Awareness in Task Force XXI.

    DTIC Science & Technology

    1997-06-01

    information dominance over the enemy and that units equipped with greater situational awareness will fight more successfully than units without the added capability. In an effort to test this hypothesis the Army conducted an Advanced Warfighter Experiment (AWE) which began at Ft. Hood, TX and culminated in a focused rotation at the National Training Center, Ft. Irwin, CA. Although many initiatives in the area of information dominance were tested in the AWE, the centerpiece of the program was a test case unit designated as Task Force Twenty-One (TF

  7. Resident away rotations allow adaptive neurosurgical training.

    PubMed

    Gephart, Melanie Hayden; Derstine, Pamela; Oyesiku, Nelson M; Grady, M Sean; Burchiel, Kim; Batjer, H Hunt; Popp, A John; Barbaro, Nicholas M

    2015-04-01

    Subspecialization of physicians and regional centers concentrate the volume of certain rare cases into fewer hospitals. Consequently, the primary institution of a neurological surgery training program may not have sufficient case volume to meet the current Residency Review Committee case minimum requirements in some areas. To ensure the competency of graduating residents through a comprehensive neurosurgical education, programs may need for residents to travel to outside institutions for exposure to cases that are either less common or more regionally focused. We sought to evaluate off-site rotations to better understand the changing demographics and needs of resident education. This would also allow prospective monitoring of modifications to the neurosurgery training landscape. We completed a survey of neurosurgery program directors and query of data from the Accreditation Council of Graduate Medical Education to characterize the current use of away rotations in neurosurgical education of residents. We found that 20% of programs have mandatory away rotations, most commonly for exposure to pediatric, functional, peripheral nerve, or trauma cases. Most of these rotations are done during postgraduate year 3 to 6, lasting 1 to 15 months. Twenty-six programs have 2 to 3 participating sites and 41 have 4 to 6 sites distinct from the host program. Programs frequently offset potential financial harm to residents rotating at a distant site by support of housing and transportation costs. As medical systems experience fluctuating treatment paradigms and demographics, over time, more residency programs may adapt to meet the Accreditation Council of Graduate Medical Education case minimum requirements through the implementation of away rotations.

  8. Testing New Physics with the Cosmic Microwave Background

    NASA Astrophysics Data System (ADS)

    Gluscevic, Vera

    2013-01-01

    In my thesis work, I have developed and applied tests of new fundamental physics that utilize high-precision CMB polarization measurements. I especially focused on a wide class of dark energy models that propose existence of new scalar fields to explain accelerated expansion of the Universe. Such fields naturally exhibit a weak interaction with photons, giving rise to "cosmic birefringence"---a rotation of the polarization plane of light traveling cosmological distances, which alters the statistics of the CMB fluctuations in the sky by inducing a characteristic B-mode polarization. A birefringent rotation of the CMB would be smoking-gun evidence that dark energy is a dynamical component rather than a cosmological constant, while its absence gives clues about the allowed regions of the parameter space for new models. I developed a full-sky formalism to search for cosmic birefringence by cross-correlating CMB temperature and polarization maps, after allowing for the rotation angle to vary across the sky. With my collaborators, I also proposed a cross-correlation of the rotation-angle estimator with the CMB temperature as a novel statistical probe which can boost signal-to-noise in the case of marginal detection and help disentangle the underlying physical models. I then investigated the degeneracy between the rotation signal and the signals from other exotic scenarios that induce a similar B-mode polarization signature, such as chiral primordial gravitational waves, and demonstrated that these effects are completely separable. Finally, I applied this formalism to WMAP-7 data and derived the first CMB constraint on the power spectrum of the birefringent-rotation angle and presented forecasts for future experiments. To demonstrate the value of this analysis method beyond the search for direction-dependent cosmic birefringence, I have also used it to probe patchy screening from the epoch of cosmic reionization with WMAP-7 data.

  9. Rotation of the planet mercury.

    PubMed

    Jefferys, W H

    1966-04-08

    The equations of motion for the rotation of Mercury are solved for the general case by an asymptotic expansion. The findings of Liu and O'Keefe, obtained by numerical integration of a special case, that it is possible for Mercury's rotation to be locked into a 2:3 resonance with its revolution, are confirmed in detail. The general solution has further applications.

  10. Energy Spectra of Strongly Stratified and Rotating Turbulence

    NASA Technical Reports Server (NTRS)

    Mahalov, Alex; Nicolaenko, Basil; Zhou, Ye

    1998-01-01

    Turbulence under strong stratification and rotation is usually characterized as quasi-two dimensional turbulence. We develop a "quasi-two dimensional" energy spectrum which changes smoothly between the Kolmogorov -5/3 law (no stratification), the -2 scalings of Zhou for the case of strong rotation, as well as the -2 scalings for the case of strong rotation and stratification. For strongly stratified turbulence, the model may give the -2 scaling predicted by Herring; and the -5/3 scaling indicated by some mesoscale observations.

  11. Neoclassical poloidal and toroidal rotation in tokamaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Y.B.; Diamond, P.H.; Groebner, R.J.

    1991-08-01

    Explicit expressions for the neoclassical poloidal and toroidal rotation speeds of primary ion and impurity species are derived via the Hirshman and Sigmar moment approach. The rotation speeds of the primary ion can be significantly different from those of impurities in various interesting cases. The rapid increase of impurity poloidal rotation in the edge region of H-mode discharges in tokamaks can be explained by a rapid steepening of the primary ion pressure gradient. Depending on ion collisionality, the poloidal rotation speed of the primary ions at the edge can be quite small and the flow direction may be opposite tomore » that of the impurities. This may cast considerable doubts on current L to H bifurcation models based on primary ion poloidal rotation only. Also, the difference between the toroidal rotation velocities of primary ions and impurities is not negligible in various cases. In Ohmic plasmas, the parallel electric field induces a large impurity toroidal rotation close to the magnetic axis, which seems to agree with experimental observations. In the ion banana and plateau regime, there can be non-negligible disparities between primary ion and impurity toroidal rotation velocities due to the ion density and temperature gradients. Detailed analytic expressions for the primary ion and impurity rotation speeds are presented, and the methodology for generalization to the case of several impurity species is also presented for future numerical evaluation.« less

  12. Comparative testing of dark matter models with 15 HSB and 15 LSB galaxies

    NASA Astrophysics Data System (ADS)

    Kun, E.; Keresztes, Z.; Simkó, A.; Szűcs, G.; Gergely, L. Á.

    2017-12-01

    Context. We assemble a database of 15 high surface brightness (HSB) and 15 low surface brightness (LSB) galaxies, for which surface brightness density and spectroscopic rotation curve data are both available and representative for various morphologies. We use this dataset to test the Navarro-Frenk-White, the Einasto, and the pseudo-isothermal sphere dark matter models. Aims: We investigate the compatibility of the pure baryonic model and baryonic plus one of the three dark matter models with observations on the assembled galaxy database. When a dark matter component improves the fit with the spectroscopic rotational curve, we rank the models according to the goodness of fit to the datasets. Methods: We constructed the spatial luminosity density of the baryonic component based on the surface brightness profile of the galaxies. We estimated the mass-to-light (M/L) ratio of the stellar component through a previously proposed color-mass-to-light ratio relation (CMLR), which yields stellar masses independent of the photometric band. We assumed an axissymetric baryonic mass model with variable axis ratios together with one of the three dark matter models to provide the theoretical rotational velocity curves, and we compared them with the dataset. In a second attempt, we addressed the question whether the dark component could be replaced by a pure baryonic model with fitted M/L ratios, varied over ranges consistent with CMLR relations derived from the available stellar population models. We employed the Akaike information criterion to establish the performance of the best-fit models. Results: For 7 galaxies (2 HSB and 5 LSB), neither model fits the dataset within the 1σ confidence level. For the other 23 cases, one of the models with dark matter explains the rotation curve data best. According to the Akaike information criterion, the pseudo-isothermal sphere emerges as most favored in 14 cases, followed by the Navarro-Frenk-White (6 cases) and the Einasto (3 cases) dark matter models. We find that the pure baryonic model with fitted M/L ratios falls within the 1σ confidence level for 10 HSB and 2 LSB galaxies, at the price of growing the M/Ls on average by a factor of two, but the fits are inferior compared to the best-fitting dark matter model.

  13. Attitude dynamics simulation subroutines for systems of hinge-connected rigid bodies with nonrigid appendages

    NASA Technical Reports Server (NTRS)

    Fleischer, G. E.; Likins, P. W.

    1975-01-01

    Three computer subroutines designed to solve the vector-dyadic differential equations of rotational motion for systems that may be idealized as a collection of hinge-connected rigid bodies assembled in a tree topology, with an optional flexible appendage attached to each body are reported. Deformations of the appendages are mathematically represented by modal coordinates and are assumed small. Within these constraints, the subroutines provide equation solutions for (1) the most general case of unrestricted hinge rotations, with appendage base bodies nominally rotating at a constant speed, (2) the case of unrestricted hinge rotations between rigid bodies, with the restriction that those rigid bodies carrying appendages are nominally nonspinning, and (3) the case of small hinge rotations and nominally nonrotating appendages. Sample problems and their solutions are presented to illustrate the utility of the computer programs.

  14. The failure mode of two reabsorbable fixation systems: Swivelock with Fibertape versus Bio-Corkscrew with Fiberwire in bovine rotator cuff.

    PubMed

    De Carli, Angelo; Lanzetti, Riccardo Maria; Monaco, Edoardo; Labianca, Luca; Mossa, Luigi; Ferretti, Andrea; Feretti, Andrea

    2012-11-01

    Despite technical advances in rotator cuff surgery, recurrent or persistent defects in the repaired tendon continue to occur. The improved strength of sutures and suture anchors has shown that the most common site of failure is the suture-tendon interface. The purpose of this study was to compare two different types of repair under both cyclic and load-to-failure conditions. The hypothesis is that the use of a fixation system with knotless anchor and taped suture results in better biomechanical performance, under both cyclic and load-to-failure conditions. Thirty bovine shoulder specimens were randomly assigned to two group tests: the Swivelock 5-mm anchor with Fibertape (Group A) and the Bio-Corkscrew 5 mm with Fiberwire (Group B). We simulated the reconstruction of a rotator cuff tear with a single-row technique, performing a tenodesis with types A and B fixation. Each specimen underwent cyclic testing from 5 to 30 N for 30 cycles, followed by load-to-failure testing, in order to calculate the ultimate failure load (UFL). Load-to-failure tests revealed a significantly higher UFL in Group A than in Group B. Wire fixing failed at the anchor loop whereas tape fixing failed at the sutures, suture-tendon interface, and anchors. Cyclic testing revealed no significantly greater slippage between the two groups. Stiffness values were not statistically significantly different. In all cases, tendons remained intact until the end of the cyclic testing. The tape structure is biomechanically stronger than the wire structure.

  15. Standardizing therapeutic parameters of acupuncture for pain suppression in rats: preliminary study.

    PubMed

    Yeo, Sujung; Lim, Hyungtaeck; Choe, Ilwhan; Kim, Sung-Hoon; Lim, Sabina

    2014-01-15

    Despite acupuncture's wide and successful use, it is still considered as lacking scientifically rigorous evidence, especially with respect to its effectiveness. To address this problem, it is necessary to re-examine the practice of acupuncture using scientific methodology. The standardization of acupuncture practices may offer a solution. As a preliminary step towards the standardization of acupuncture stimulation in animal experiments, this study attempted to clarify the various therapeutic parameters that contribute to acupuncture's efficacy. This study identified specific acupoints, temporal point of needling, rotation of the needle, duration of acupuncture, and diameter of the needle as the parameters, through formalin test. In this test, acupuncture was performed on either the ST36 or LR2 point immediately after pain induction and 5 minutes after pain induction. The formalin test yielded no significant suppression of pain in the case of ST36 and LR2 acupuncture stimulation immediately following pain induction. When acupuncture was applied 5 minutes after pain induction, however, the ST36 stimulation resulted in a significant decrease in pain, while the LR2 stimulation produced no change. The duration of acupuncture, but not the diameter of the needle, was also significant. As for the rotation of the needle, there was no significant difference in the pain reduction achieved in the rotation and non-rotation groups. We determined that specific acupoint, temporal point of needling, and duration of treatment are important factors in the inhibition of pain. These finding strongly suggest that in animal experiments, the application of a set of appropriate therapeutic parameters can significantly influence the outcome.

  16. Photogrammetric Trajectory Estimation of Foam Debris Ejected From an F-15 Aircraft

    NASA Technical Reports Server (NTRS)

    Smith, Mark S.

    2006-01-01

    Photogrammetric analysis of high-speed digital video data was performed to estimate trajectories of foam debris ejected from an F-15B aircraft. This work was part of a flight test effort to study the transport properties of insulating foam shed by the Space Shuttle external tank during ascent. The conical frustum-shaped pieces of debris, called "divots," were ejected from a flight test fixture mounted underneath the F-15B aircraft. Two onboard cameras gathered digital video data at two thousand frames per second. Time histories of divot positions were determined from the videos post flight using standard photogrammetry techniques. Divot velocities were estimated by differentiating these positions with respect to time. Time histories of divot rotations were estimated using four points on the divot face. Estimated divot position, rotation, and Mach number for selected cases are presented. Uncertainty in the results is discussed.

  17. Four cases of vertebrobasilar insufficiency.

    PubMed

    Inui, H; Yoneyama, K; Kitaoku, Y; Nakane, M; Ohue, S; Yamanaka, T; Ueda, T; Fujita, N; Miyahara, H; Matsunaga, T

    1998-01-01

    Four cases of vertebrobasilar insufficiency are reported. Case 1 was a 38-year-old man who felt a sudden onset of dizziness when he turned his head to the back. An abnormal positional nystagmus was observed when he rotated his head to the left. A magnetic resonance angiogram (MRA) demonstrated total occlusion of the left vertebral artery (VA). Case 2 was a 31-year-old woman who had a total occlusion of her left VA as observed in the MRA. Case 3 was a 68-year-old man who noted dizziness. The systolic blood pressure change on his Schellong test was 28 mmHg. On his MRA, severe displacement of the basilar and the vertebral arteries was visible. Case 4 was a 76-year-old woman who noted a blackout-like sensation. Optokinetic nystagmus was noted with a hyponystagmus pattern, and an eye tracking test showed a saccadic pattern. On her MRA, the vertebrobasilar system was narrowed. The arterial architecture and any stenosis of the blood vessels could be detected non-invasively by MRA.

  18. Pediatric surgical capacity building - a pathway to improving access to pediatric surgical care in Haiti.

    PubMed

    Kaseje, Neema; Jenny, Hillary; Jeudy, Andre Patrick; MacLee, Jean Louis; Meara, John G; Ford, Henri R

    2018-02-01

    Lack of human resources is a major barrier to accessing pediatric surgical care globally. Our aim was to establish a model for pediatric surgical training of general surgery residents in a resource constrained region. A pediatric surgical program with a pediatric surgical rotation for general surgery residents in a tertiary hospital in Haiti in 2015 was established. We conducted twice daily patient rounds, ran an outpatient clinic, and provided emergent and elective pediatric surgical care, with tasks progressively given to residents until they could run clinic and perform the most common elective and emergent procedures. We conducted baseline and post-intervention knowledge exams and dedicated 1 day a week to teaching and research activities. We measured the following outcomes: number of residents that completed the rotation, mean pre and post intervention test scores, patient volume in clinic and operating room, postoperative outcomes, resident ability to perform most common elective and emergent procedures, and resident participation in research. Nine out of 9 residents completed the rotation; 987 patients were seen in outpatient clinic, and 564 procedures were performed in children <15years old. There was a 50% increase in volume of pediatric cases and a 100% increase in procedures performed in children <4years old. Postoperative outcomes were: 0% mortality for elective cases and 18% mortality for emergent cases, 3% complication rate for elective cases and 6% complication rate for emergent cases. Outcomes did not change with increased responsibility given to residents. All senior residents (n=4) could perform the most common elective and emergent procedures without changes in mortality and complication rates. Increases in mean pre and post intervention test scores were 12% (PGY1), 24% (PGY2), and 10% (PGY3). 75% of senior residents participated in research activities as first or second authors. Establishing a program in pediatric surgery with capacity building of general surgery residents for pediatric surgical care provision is feasible in a resource constrained setting without negative effects on patient outcomes. This model can be applied in other resource constrained settings to increase human resources for global pediatric surgical care provision. III. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. The machinability of cast titanium and Ti-6Al-4V.

    PubMed

    Ohkubo, C; Watanabe, I; Ford, J P; Nakajima, H; Hosoi, T; Okabe, T

    2000-02-01

    This study investigated the machinability (ease of metal removal) of commercially pure (CP) titanium and Ti-6Al-4V alloy. Both CP Ti and Ti-6Al-4V were cast into magnesia molds. Two types of specimens (with alpha-case and without alpha-case) were made for CP Ti and Ti-6Al-4V. Machinability (n = 5) was evaluated as volume loss (mm3) by cutting/grinding the 3.0 mm surface using fissure burs and silicon carbide (SiC) under two machining conditions: (1) two machining forces (100 or 300 gf) at two rotational speeds (15000 or 30000 rpm) for 1 min, and (2) constant machining force of 100 gf and rotational speed of 15000 rpm for 1, 2, 5, 10, and 30 min. As controls, conventionally cast Co-Cr and Type IV gold alloys were evaluated in the same manner as the titanium. When fissure burs were used, there was a significant difference in the machinability between CP titanium with alpha-case and without alpha-case. On the other hand, there was no appreciable difference in the amount of metal removed for each tested metal when using the SiC points.

  20. Symmetry classes of the anisotropy tensors of quasielastic materials and a generalized Kelvin approach

    NASA Astrophysics Data System (ADS)

    Ostrosablin, N. I.

    2017-05-01

    The anisotropy matrices (tensors) of quasielastic (Cauchy-elastic) materials were obtained for all classes of crystallographic symmetries in explicit form. The fourth-rank anisotropy tensors of such materials do not have the main symmetry, in which case the anisotropy matrix is not symmetric. As a result of introducing various bases in the space of symmetric stress and strain tensors, the linear relationship between stresses and strains is represented in invariant form similar to the form in which generalized Hooke's law is written for the case of anisotropic hyperelastic materials and contains six positive Kelvin eigen moduli. It is shown that the introduction of modified rotation-induced deformation in the strain space can cause a transition to the symmetric anisotropy matrix observed in the case of hyperelasticity. For the case of transverse isotropy, there are examples of determination of the Kelvin eigen moduli and eigen bases and the rotation matrix in the strain space. It is shown that there is a possibility of existence of quasielastic media with a skew-symmetric anisotropy matrix with no symmetric part. Some techniques for the experimental testing of the quasielasticity model are proposed.

  1. Determination of consistent patterns of range of motion in the ankle joint with a computed tomography stress-test.

    PubMed

    Tuijthof, Gabriëlle Josephine Maria; Zengerink, Maartje; Beimers, Lijkele; Jonges, Remmet; Maas, Mario; van Dijk, Cornelis Niek; Blankevoort, Leendert

    2009-07-01

    Measuring the range of motion of the ankle joint can assist in accurate diagnosis of ankle laxity. A computed tomography-based stress-test (3D CT stress-test) was used that determines the three-dimensional position and orientation of tibial, calcaneal and talar bones. The goal was to establish a quantitative database of the normal ranges of motion of the talocrural and subtalar joints. A clinical case on suspected subtalar instability demonstrated the relevance the proposed method. The range of motion was measured for the ankle joints in vivo for 20 subjects using the 3D CT stress-test. Motion of the tibia and calcaneus relative to the talus for eight extreme foot positions were described by helical parameters. High consistency for finite helical axis orientation (n) and rotation (theta) was shown for: talocrural extreme dorsiflexion to extreme plantarflexion (root mean square direction deviation (eta) 5.3 degrees and theta: SD 11.0 degrees), talorucral and subtalar extreme combined eversion-dorsiflexion to combined inversion-plantarflexion (eta: 6.7 degrees , theta: SD 9.0 degrees and eta:6.3 degrees , theta: SD 5.1 degrees), and subtalar extreme inversion to extreme eversion (eta: 6.4 degrees, theta: SD 5.9 degrees). Nearly all dorsi--and plantarflexion occurs in the talocrural joint (theta: mean 63.3 degrees (SD 11 degrees)). The inversion and internal rotation components for extreme eversion to inversion were approximately three times larger for the subtalar joint (theta: mean 22.9 degrees and 29.1 degrees) than for the talocrural joint (theta: mean 8.8 degrees and 10.7 degrees). Comparison of the ranges of motion of the pathologic ankle joint with the healthy subjects showed an increased inversion and axial rotation in the talocrural joint instead of in the suspected subtalar joint. The proposed diagnostic technique and the acquired database of helical parameters of ankle joint ranges of motion are suitable to apply in clinical cases.

  2. Ultimate Lateral Capacity of Rigid Pile in c- φ Soil

    NASA Astrophysics Data System (ADS)

    Zhang, Wei-min

    2018-03-01

    To date no analytical solution of the pile ultimate lateral capacity for the general c- φ soil has been obtained. In the present study, a new dimensionless embedded ratio was proposed and the analytical solutions of ultimate lateral capacity and rotation center of rigid pile in c- φ soils were obtained. The results showed that both the dimensionless ultimate lateral capacity and dimensionless rotation center were the univariate functions of the embedded ratio. Also, the ultimate lateral capacity in the c- φ soil was the combination of the ultimate lateral capacity ( f c ) in the clay, and the ultimate lateral capacity ( f φ ) in the sand. Therefore, the Broms chart for clay, solution for clay ( φ=0) put forward by Poulos and Davis, solution for sand ( c=0) obtained by Petrasovits and Awad, and Kondner's ultimate bending moment were all proven to be the special cases of the general solution in the present study. A comparison of the field and laboratory tests in 93 cases showed that the average ratios of the theoretical values to the experimental value ranged from 0.85 to 1.15. Also, the theoretical values displayed a good agreement with the test values.

  3. Radial dependence of the dark matter distribution in M33

    NASA Astrophysics Data System (ADS)

    López Fune, E.; Salucci, P.; Corbelli, E.

    2017-06-01

    The stellar and gaseous mass distributions, as well as the extended rotation curve, in the nearby galaxy M33 are used to derive the radial distribution of dark matter density in the halo and to test cosmological models of galaxy formation and evolution. Two methods are examined to constrain the dark mass density profiles. The first method deals directly with fitting the rotation curve data in the range of galactocentric distances 0.24 ≤ r ≤ 22.72 kpc. Using the results of collisionless Λ cold dark matter numerical simulations, we confirm that the Navarro-Frenkel-White (NFW) dark matter profile provides a better fit to the rotation curve data than the cored Burkert profile (BRK) profile. The second method relies on the local equation of centrifugal equilibrium and on the rotation curve slope. In the aforementioned range of distances, we fit the observed velocity profile, using a function that has a rational dependence on the radius, and we derive the slope of the rotation curve. Then, we infer the effective matter densities. In the radial range 9.53 ≤ r ≤ 22.72 kpc, the uncertainties induced by the luminous matter (stars and gas) become negligible, because the dark matter density dominates, and we can determine locally the radial distribution of dark matter. With this second method, we tested the NFW and BRK dark matter profiles and we can confirm that both profiles are compatible with the data, even though in this case the cored BRK density profile provides a more reasonable value for the baryonic-to-dark matter ratio.

  4. Einstein-aether theory: dynamics of relativistic particles with spin or polarization in a Gödel-type universe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balakin, Alexander B.; Popov, Vladimir A., E-mail: alexander.balakin@kpfu.ru, E-mail: vladipopov@mail.ru

    In the framework of the Einstein-aether theory we consider a cosmological model, which describes the evolution of the unit dynamic vector field with activated rotational degree of freedom. We discuss exact solutions of the Einstein-aether theory, for which the space-time is of the Gödel-type, the velocity four-vector of the aether motion is characterized by a non-vanishing vorticity, thus the rotational vectorial modes can be associated with the source of the universe rotation. The main goal of our paper is to study the motion of test relativistic particles with a vectorial internal degree of freedom (spin or polarization), which is coupledmore » to the unit dynamic vector field. The particles are considered as the test ones in the given space-time background of the Gödel-type; the spin (polarization) coupling to the unit dynamic vector field is modeled using exact solutions of three types. The first exact solution describes the aether with arbitrary Jacobson's coupling constants; the second one relates to the case, when the Jacobson's constant responsible for the vorticity is vanishing; the third exact solution is obtained using three constraints for the coupling constants. The analysis of the exact expressions, which are obtained for the particle momentum and for the spin (polarization) four-vector components, shows that the interaction of the spin (polarization) with the unit vector field induces a rotation, which is additional to the geodesic precession of the spin (polarization) associated with the universe rotation as a whole.« less

  5. Intraoperative assessment of the stability of the distal tibiofibular joint in supination-external rotation injuries of the ankle: sensitivity, specificity, and reliability of two clinical tests.

    PubMed

    Pakarinen, Harri; Flinkkilä, Tapio; Ohtonen, Pasi; Hyvönen, Pekka; Lakovaara, Martti; Leppilahti, Juhana; Ristiniemi, Jukka

    2011-11-16

    This study was designed to assess the sensitivity, specificity, and interobserver reliability of the hook test and the stress test for the intraoperative diagnosis of instability of the distal tibiofibular joint following fixation of ankle fractures resulting from supination-external rotation forces. We conducted a prospective study of 140 patients with an unstable unilateral ankle fracture resulting from a supination-external rotation mechanism (Lauge-Hansen SE). After internal fixation of the malleolar fracture, a hook test and an external rotation stress test under fluoroscopy were performed independently by the lead surgeon and assisting surgeon, followed by a standardized 7.5-Nm external rotation stress test of each ankle under fluoroscopy. A positive stress test result was defined as a side-to-side difference of >2 mm in the tibiotalar or the tibiofibular clear space on mortise radiographs. The sensitivity and specificity of each test were calculated with use of the standardized 7.5-Nm external rotation stress test as a reference. Twenty-four (17%) of the 140 patients had a positive standardized 7.5-Nm external rotation stress test after internal fixation of the malleolar fracture. The hook test had a sensitivity of 0.25 (95% confidence interval, 0.12 to 0.45) and a specificity of 0.98 (95% confidence interval, 0.94 to 1.0) for the detection of the same instabilities. The external rotation stress test had a sensitivity of 0.58 (95% confidence interval, 0.39 to 0.76) and a specificity of 0.96 (95% confidence interval, 0.90 to 0.98). Both tests had excellent interobserver reliability, with 99% agreement for the hook test and 98% for the stress test. Interobserver agreement for the hook test and the clinical stress test was excellent, but the sensitivity of these tests was insufficient to adequately detect instability of the syndesmosis intraoperatively.

  6. Convection and Overshoot in Models of Doradus and Scuti Stars

    DOE PAGES

    Lovekin, Catherine C.; Guzik, Joyce Ann

    2017-10-27

    We investigate the pulsation properties of stellar models that are representative of δ Scuti and γ Doradus variables. Here we have calculated a grid of stellar models from 1.2 to 2.2 M ⊙, including the effects of both rotation and convective overshoot using MESA, and we investigate the pulsation properties of these models using GYRE. We discuss the observable patterns in the frequency spacing for p modes and the period spacings for g modes. Using the observable patterns in the g mode period spacings, it may be possible to observationally constrain the convective overshoot and rotation of a model. Wemore » also calculate the pulsation constant (Q) for all models in our grid and investigate the variation with convective overshoot and rotation. The variation in the Q values of the radial modes can be used to place constraints on the convective overshoot and rotation of stars in this region. Finally, as a test case, we apply this method to a sample of 22 High-Amplitude δ Scuti stars (HADS) and provide estimates for the convective overshoot of the sample.« less

  7. Changes in the biological activity of chestnut soils upon the long-term application of fertilizers in a rotation with oil-bearing crops

    NASA Astrophysics Data System (ADS)

    Eleshev, R. E.; Bakenova, Z. B.

    2012-11-01

    Experimental studies showed that irrigated chestnut soils on the piedmont of the Zailiiskiy Alatau Range are characterized by the moderate activity of the hydrolytic and redox enzymes. The use of these soils in the crop rotation system increases the hydrolytic activity of the enzymes (invertase, urease, and ATP synthase) by 30% in comparison with the monoculture; at the same time, it does not have a significant impact on the changes in the biological activity of the redox enzymes (catalase and dehydrogenase). The hydrolytic activity of the soils is activated to a greater extent in the crop rotation and in the monoculture against the background application of organic fertilizers. In this case, the recommended rates of mineral fertilizers do not inhibit the activity of the hydrolytic and redox enzymes. An increase in the hydrolytic activity of the enzymes directly affects the yield of oilseed flax. Therefore, indices of the hydrolytic activity of soils can be used as a test for the diagnostics of the efficiency of fertilizers both in crop rotation and monoculture systems.

  8. Convection and Overshoot in Models of Doradus and Scuti Stars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lovekin, Catherine C.; Guzik, Joyce Ann

    We investigate the pulsation properties of stellar models that are representative of δ Scuti and γ Doradus variables. Here we have calculated a grid of stellar models from 1.2 to 2.2 M ⊙, including the effects of both rotation and convective overshoot using MESA, and we investigate the pulsation properties of these models using GYRE. We discuss the observable patterns in the frequency spacing for p modes and the period spacings for g modes. Using the observable patterns in the g mode period spacings, it may be possible to observationally constrain the convective overshoot and rotation of a model. Wemore » also calculate the pulsation constant (Q) for all models in our grid and investigate the variation with convective overshoot and rotation. The variation in the Q values of the radial modes can be used to place constraints on the convective overshoot and rotation of stars in this region. Finally, as a test case, we apply this method to a sample of 22 High-Amplitude δ Scuti stars (HADS) and provide estimates for the convective overshoot of the sample.« less

  9. Convection and Overshoot in Models of γ Doradus and δ Scuti Stars

    NASA Astrophysics Data System (ADS)

    Lovekin, C. C.; Guzik, J. A.

    2017-11-01

    We investigate the pulsation properties of stellar models that are representative of δ Scuti and γ Doradus variables. We have calculated a grid of stellar models from 1.2 to 2.2 M ⊙, including the effects of both rotation and convective overshoot using MESA, and we investigate the pulsation properties of these models using GYRE. We discuss the observable patterns in the frequency spacing for p modes and the period spacings for g modes. Using the observable patterns in the g mode period spacings, it may be possible to observationally constrain the convective overshoot and rotation of a model. We also calculate the pulsation constant (Q) for all models in our grid and investigate the variation with convective overshoot and rotation. The variation in the Q values of the radial modes can be used to place constraints on the convective overshoot and rotation of stars in this region. As a test case, we apply this method to a sample of 22 High-Amplitude δ Scuti stars (HADS) and provide estimates for the convective overshoot of the sample.

  10. Large-eddy substitution via vortex cancellation for wall turbulence control

    NASA Technical Reports Server (NTRS)

    Mcginley, C. B.; Beeler, G. B.

    1985-01-01

    A system of co-rotating longitudinal vortices was used to introduce streamline (as opposed to wall) curvature into a turbulent wall flow. Two methods of vortex cancellation, unwinding and self-annihilation, were tested as a means of removing the vortices once they had processed most of the incoming turbulent boundary layer. Vortex unwinding, which uses vorticity of the opposite sign, was shown to be a viable method for cancelling the co-rotating vortices. Vortex self-annihilation, caused by interference effects resulting from a close initial spanwise vortex spacing, eliminated the vortices within 60 delta downstream. In each case, reductions in boundary layer entrainment were found once the vortices were cancelled.

  11. The horizontal computerized rotational impulse test.

    PubMed

    Furman, Joseph M; Shirey, Ian; Roxberg, Jillyn; Kiderman, Alexander

    2016-01-01

    Whole-body impulsive rotations were used to overcome several limitations associated with manual head impulse testing. A computer-controlled rotational chair delivered brief, whole-body, earth-vertical axis yaw impulsive rotations while eye movements were measured using video-oculography. Results from an unselected group of 20 patients with dizziness and a group of 22 control subjects indicated that the horizontal computerized rotational head impulse test (crHIT) is well-tolerated and provides an estimate of unidirectional vestibulo-ocular reflex gain comparable to results from caloric testing. This study demonstrates that the horizontal crHIT is a new assessment tool that overcomes many of the limitations of manual head impulse testing and provides a reliable laboratory-based measure of unilateral horizontal semicircular canal function.

  12. Analysis of Iliac Artery Geometric Properties in Fenestrated Aortic Stent Graft Rotation.

    PubMed

    Doyle, Matthew G; Crawford, Sean A; Osman, Elrasheed; Eisenberg, Naomi; Tse, Leonard W; Amon, Cristina H; Forbes, Thomas L

    2018-04-01

    A complication of fenestrated endovascular aneurysm repair is the potential for stent graft rotation during deployment causing fenestration misalignment and branch artery occlusion. The objective of this study is to demonstrate that this rotation is caused by a buildup of rotational energy as the device is delivered through the iliac arteries and to quantify iliac artery geometric properties associated with device rotation. A retrospective clinical study was undertaken in which iliac artery geometric properties were assessed from preoperative imaging for 42 cases divided into 2 groups: 27 in the nonrotation group and 15 in the rotation group. Preoperative computed tomography scans were segmented, and the iliac artery centerlines were determined. Iliac artery tortuosity, curvature, torsion, and diameter were calculated from the centerline and the segmented vessel geometry. The total iliac artery net torsion was found to be higher in the rotation group compared to the nonrotation group (23.5 ± 14.7 vs 14.6 ± 12.8 mm -1 ; P = .05). No statistically significant differences were found for the mean values of tortuosity, curvature, torsion, or diameter between the 2 groups. Stent graft rotation occurred in 36% of the cases considered in this study. Cases with high iliac artery total net torsion were found to be more likely to have stent graft rotation upon deployment. This retrospective study provides a framework for prospectively studying the influence of iliac artery geometric properties on fenestrated stent graft rotation.

  13. Experimental study on a heavy-gas cylinder accelerated by cylindrical converging shock waves

    NASA Astrophysics Data System (ADS)

    Si, T.; Zhai, Z.; Luo, X.; Yang, J.

    2014-01-01

    The Richtmyer-Meshkov instability behavior of a heavy-gas cylinder accelerated by a cylindrical converging shock wave is studied experimentally. A curved wall profile is well-designed based on the shock dynamics theory [Phys. Fluids, 22: 041701 (2010)] with an incident planar shock Mach number of 1.2 and a converging angle of in a mm square cross-section shock tube. The cylinder mixed with the glycol droplets flows vertically through the test section and is illuminated horizontally by a laser sheet. The images obtained only one per run by an ICCD (intensified charge coupled device) combined with a pulsed Nd:YAG laser are first presented and the complete evolution process of the cylinder is then captured in a single test shot by a high-speed video camera combined with a high-power continuous laser. In this way, both the developments of the first counter-rotating vortex pair and the second counter-rotating vortex pair with an opposite rotating direction from the first one are observed. The experimental results indicate that the phenomena induced by the converging shock wave and the reflected shock formed from the center of convergence are distinct from those found in the planar shock case.

  14. Forward rotor vortex effects on counter rotating propeller noise

    NASA Technical Reports Server (NTRS)

    Laur, Michele; Squires, Becky; Nagel, Robert T.

    1992-01-01

    Three configurations of a model counter rotating propeller manipulate the blade tip flow by: placing the CRP at angle of attack, installing shrouds, and turning the upstream blades to provide forward sweep. Flow visualization and flow measurements with thermal anemometry show no evidence of a tip vortex; however, a leading edge vortex was detected on aft swept blades. The modifications served to alter the strength and/or path of the leading edge vortex. The vortical flow is eliminated by forward sweep on the upstream propeller blades. Far field acoustic data from each test indicate only small influences on the level and directivity of the BPFs. The interaction tone at the sum of the two BPF's was significantly altered in a consistent manner. As the vortex system varied, the interaction tone was affected: far field noise levels in the forward quandrant increased and the characteristic noise minimum near the plane of rotation became less pronounced and in some cases were eliminated. If the forward propeller leading edge vortex system does not impact the rear propeller in the standard manner, a net increase in the primary interaction tone occurs for the model tested. If the leading edge vortex is removed, the interaction tone increases.

  15. High School Students' Performance on Vandenberg's Mental Rotations Test: Art Ability, Gender, Activities, Academic Performance, Strategies, and Ease of Taking the Test.

    ERIC Educational Resources Information Center

    Gurny, Helen Graham

    This study tested whether mental rotation performance of 186 high school students (80 males and 106 females) in grades 9 through 12 in art and nonart classes on Vandenbergs Mental Rotations test (S. Vandenberg and Kuse, 1978) was affected by gender, visual-spatial activities, strategies used while performing the test, and the ease of test taking.…

  16. On the Stability of Periodic Mercury-type Rotations

    NASA Astrophysics Data System (ADS)

    Churkina, Tatyana E.; Stepanov, Sergey Y.

    2017-12-01

    We consider the stability of planar periodic Mercury-type rotations of a rigid body around its center of mass in an elliptical orbit in a central Newtonian field of forces. Mercurytype rotations mean that the body makes 3 turns around its center of mass during 2 revolutions of the center of mass in its orbit (resonance 3:2). These rotations can be 1) symmetrical 2π- periodic, 2) symmetrical 4π-periodic and 3) asymmetrical 4π-periodic. The stability of rotations of type 1) was investigated by A.P.Markeev. In our paper we present a nonlinear stability analysis for some rotations of types 2) and 3) in 3rd- and 4th-order resonant cases, in the nonresonant case and at the boundaries of regions of linear stability.

  17. Co-existence and switching between fast and Ω-slow wind solutions in rapidly rotating massive stars

    NASA Astrophysics Data System (ADS)

    Araya, I.; Curé, M.; ud-Doula, A.; Santillán, A.; Cidale, L.

    2018-06-01

    Most radiation-driven winds of massive stars can be modelled with m-CAK theory, resulting in the so-called fast solution. However, the most rapidly rotating stars among them, especially when the rotational speed is higher than {˜ } 75 per cent of the critical rotational speed, can adopt a different solution, the so-called Ω-slow solution, characterized by a dense and slow wind. Here, we study the transition region of the solutions where the fast solution changes to the Ω-slow solution. Using both time-steady and time-dependent numerical codes, we study this transition region for various equatorial models of B-type stars. In all cases, in a certain range of rotational speeds we find a region where the fast and the Ω-slow solution can co-exist. We find that the type of solution obtained in this co-existence region depends stongly on the initial conditions of our models. We also test the stability of the solutions within the co-existence region by performing base-density perturbations in the wind. We find that under certain conditions, the fast solution can switch to the Ω-slow solution, or vice versa. Such solution-switching may be a possible contributor of material injected into the circumstellar environment of Be stars, without requiring rotational speeds near critical values.

  18. Muscle Weakness in the Empty and Full Can Tests Cannot Differentiate Rotator Cuff Tear from Cervical Spondylotic Amyotrophy: Pain Provocation is a Useful Finding.

    PubMed

    Iwata, Eiichiro; Shigematsu, Hideki; Inoue, Kazuya; Egawa, Takuya; Sakamoto, Yoshihiro; Tanaka, Yasuhito

    2017-01-01

    Rotator cuff tears and cervical spondylotic amyotrophy (CSA) are often confused as the main symptom in those with difficulty in shoulder elevation. Empty and full can tests are frequently used for the clinical diagnosis of rotator cuff tears. The aim of the present study was to investigate whether the empty and full can test results can help differentiate rotator cuff tears from CSA. Twenty-seven consecutive patients with rotator cuff tears and 25 with CSA were enrolled. We prospectively performed empty and full can tests in patients with rotator cuff tears and CSA. The following signs were considered positive: (a) muscle weakness during the empty can test, (b) muscle weakness during the full can test, (c) pain provocation during the empty can test, and (d) pain provocation during the full can test. We calculated the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of rotator cuff tears for each positive finding. The sensitivity and specificity of each index were as follows (sensitivity, specificity, PPV, NPV): (a) 77.8%, 0%, 45.7%, 0%; (b) 66.7%, 4.0%, 42.9%, 10.0%; (c) 88.9%, 96.0%, 96.0%, 88.9%; and (d) 74.1%, 96.0%, 95.2%, 77.4%. There were significant differences for each index. Muscle weakness during the empty and full can tests was not useful in differentiating rotator cuff tears from CSA because of low specificity and PPV. However, pain provocation was useful in differentiating these two conditions because of high specificity and PPV.

  19. Correlation of glenohumeral internal rotation deficit and total rotational motion to shoulder injuries in professional baseball pitchers.

    PubMed

    Wilk, Kevin E; Macrina, Leonard C; Fleisig, Glenn S; Porterfield, Ronald; Simpson, Charles D; Harker, Paul; Paparesta, Nick; Andrews, James R

    2011-02-01

    Glenohumeral internal rotation deficit (GIRD) indicates a 20° or greater loss of internal rotation of the throwing shoulder compared with the nondominant shoulder. To determine whether GIRD and a deficit in total rotational motion (external rotation + internal rotation) compared with the nonthrowing shoulder correlate with shoulder injuries in professional baseball pitchers. Case series; Level of evidence, 4. Over 3 competitive seasons (2005 to 2007), passive range of motion measurements were evaluated on the dominant and nondominant shoulders for 170 pitcher-seasons. This included 122 professional pitchers during the 3 seasons of data collection, in which some pitchers were measured during multiple seasons. Ranges of motion were measured with a bubble goniometer during the preseason, by the same examiner each year. External and internal rotation of the glenohumeral joint was assessed with the participant supine and the arm abducted 90° in the plane of the scapula, with the scapula stabilized anteriorly at the coracoid process. The reproducibility of the test methods had an intraclass correlation coefficient of .81. Days in which the player was unable to participate because of injury or surgery were recorded during the season by the medical staff of the team and defined as an injury. Pitchers with GIRD (n = 40) were nearly twice as likely to be injured as those without but without statistical significance (P = .17). Pitchers with total rotational motion deficit greater than 5° had a higher rate of injury. Minor league pitchers were more likely than major league pitchers to be injured. However, when players were injured, major league pitchers missed a significantly greater number of games than minor league pitchers. Compared with pitchers without GIRD, pitchers with GIRD appear to be at a higher risk for injury and shoulder surgery.

  20. Sleep disturbance associated with rotator cuff tear: correction with arthroscopic rotator cuff repair.

    PubMed

    Austin, Luke; Pepe, Matthew; Tucker, Bradford; Ong, Alvin; Nugent, Robert; Eck, Brandon; Tjoumakaris, Fotios

    2015-06-01

    Sleep disturbance is a common complaint of patients with a rotator cuff tear. Inadequate and restless sleep, along with pain, is often a driving symptom for patients to proceed with rotator cuff repair. To date, no studies have examined sleep disturbance in patients undergoing rotator cuff repair, and there is no evidence that surgery improves sleep disturbance. Sleep disturbance is prevalent in patients with a symptomatic rotator cuff tear, and sleep disturbance improves after arthroscopic rotator cuff repair. Case series; Level of evidence, 4. A total of 56 patients undergoing arthroscopic rotator cuff repair for full-thickness tears were enrolled in a prospective study. Patients were surveyed preoperatively and postoperatively at intervals of 2, 6, 12, 18, and 24 weeks. Patient outcomes were scored using the Pittsburgh Sleep Quality Index (PSQI), Simple Shoulder Test (SST), visual analog scale for pain (VAS), and single assessment numeric evaluation (SANE). Demographic and surgical factors were also collected for analysis. Preoperative PSQI scores indicative of sleep disturbance were reported in 89% of patients. After surgery, a statistically significant improvement in PSQI was achieved at 3 months (P = .0012; 91% follow-up) and continued through 6 months (P = .0179; 93% follow-up). Six months after surgery, only 38% of patients continued to have sleep disturbance. Multivariable linear regression of all surgical and demographic factors versus PSQI was performed and demonstrated that preoperative and prolonged postoperative narcotic use negatively affected sleep. Sleep disturbance is common in patients undergoing rotator cuff repair. After surgery, sleep disturbance improves to levels comparable with those of the general public. Preoperative and prolonged postoperative use of narcotic pain medication negatively affects sleep. © 2015 The Author(s).

  1. The Effect of Spanwise System Rotation on Turbulent Poiseuille Flow at Very-Low-Reynolds Number

    NASA Astrophysics Data System (ADS)

    Iida, Oaki; Fukudome, K.; Iwata, T.; Nagano, Y.

    Direct numerical simulations (DNSs) with a spectral method are performed with large and small computational domains to study the effects of spanwise rotation on a turbulent Poiseuille flow at the very low-Reynolds numbers. In the case without system rotation, quasi-laminar and turbulent states appear side by side in the same computational domain, which is coined as laminar-turbulence pattern. However, in the case with system rotation, the pattern disappears and flow is dominated by quasi-laminar region including very long low-speed streaks coiled by chain-like vortical structures. Increasing the Reynolds number can not generate the laminar-turbulence pattern as long as system rotation is imposed.

  2. Reliability of Measurement of Glenohumeral Internal Rotation, External Rotation, and Total Arc of Motion in 3 Test Positions

    PubMed Central

    Kevern, Mark A.; Beecher, Michael; Rao, Smita

    2014-01-01

    Context: Athletes who participate in throwing and racket sports consistently demonstrate adaptive changes in glenohumeral-joint internal and external rotation in the dominant arm. Measurements of these motions have demonstrated excellent intrarater and poor interrater reliability. Objective: To determine intrarater reliability, interrater reliability, and standard error of measurement for shoulder internal rotation, external rotation, and total arc of motion using an inclinometer in 3 testing procedures in National Collegiate Athletic Association Division I baseball and softball athletes. Design: Cross-sectional study. Setting: Athletic department. Patients or Other Participants Thirty-eight players participated in the study. Shoulder internal rotation, external rotation, and total arc of motion were measured by 2 investigators in 3 test positions. The standard supine position was compared with a side-lying test position, as well as a supine test position without examiner overpressure. Results: Excellent intrarater reliability was noted for all 3 test positions and ranges of motion, with intraclass correlation coefficient values ranging from 0.93 to 0.99. Results for interrater reliability were less favorable. Reliability for internal rotation was highest in the side-lying position (0.68) and reliability for external rotation and total arc was highest in the supine-without-overpressure position (0.774 and 0.713, respectively). The supine-with-overpressure position yielded the lowest interrater reliability results in all positions. The side-lying position had the most consistent results, with very little variation among intraclass correlation coefficient values for the various test positions. Conclusions: The results of our study clearly indicate that the side-lying test procedure is of equal or greater value than the traditional supine-with-overpressure method. PMID:25188316

  3. Prospective Randomized Trial Comparing Embryo Transfers of Cases with and without Catheter Rotation during Its Withdrawal.

    PubMed

    Yayla Abide, Cigdem; Ozkaya, Enis; Sanverdi, Ilhan; Bostancı Ergen, Evrim; Kurek Eken, Meryem; Devranoglu, Belgin; Bilgiç, Bulent Emre; Kilicci, Cetin; Kayatas Eser, Semra

    2018-05-14

    To compare embryo transfer (ET) technique based on catheter rotation during its withdrawal in cases with unexplained infertility in a prospective, randomized trial (NCT03097042). Two hundred intracytoplasmic sperm injection (ICSI) patients undergoing ET with cleaving or blastocyst-stage fresh embryos were randomized into 2 groups: cases with (n = 100), and without (n = 100) catheter rotation during its withdrawal. Groups were matched for age and some clinical parameters. A soft catheter was used to transfer a single embryo with catheter rotation during its withdrawal in the study group and without rotation in the control. The use of a stiff catheter or tenaculum was not needed in any case. Groups were compared in terms of cycle characteristics and clinical pregnancy rates. Pregnancy rate was significantly higher in the study group (41 vs. 26%, p = 0.04). Clinical pregnancy rate was also significantly higher in the study group (39 vs. 25%, OR 1.9 [1.1-3.5], p = 0.05). On the other hand, the ongoing pregnancy rate was similar between the 2 groups (33 vs. 23%, p = 0.2). Catheter rotation during its withdrawal may be associated with increased pregnancy and clinical pregnancy rates; however, the difference in ongoing pregnancy rates did not reach statistical significance. © 2018 S. Karger AG, Basel.

  4. A novel approach of magnetorheological abrasive fluid finishing with swirling-assisted inlet flow

    NASA Astrophysics Data System (ADS)

    Kheradmand, Saeid; Esmailian, Mojtaba; Fatahy, A.

    Abrasive flow machining has been the pioneer of new finishing processes. Rotating workpiece and imposing a magnetic field using magnetorheological working medium are some assisting manipulations to improve surface finishing, because they can increase the forces on the workpiece surface. Similarly, swirling the inlet flow using stationary swirler vanes, as a novel idea, may also increase forces on the surface, and then raise the material removal, with a lower expense and energy consumption compared with the case of workpiece rotation. Thus, in this paper, surface roughness improvement is studied in a pipe with rotating inlet flow of a magnetorheological finishing medium under imposing a magnetic field. The results are compared with the case of rotating workpiece, using 3D numerical simulation. The governing hydrodynamic parameters are investigated in both cases to monitor the flow variations. It is shown that surface roughness is improved by rotating inlet flow. However, it is found that finishing in the entrance length of swirling-assisted inlet flow can be so economical for short length workpieces, compared with the case of rotating workpiece, with very near Ra values. By comparison of the numerical results and published experimental data, current study also shows the ability of the numerical simulation, as an inexpensive and efficient tool, to predict the surface roughness changes in finishing processes.

  5. Does autologous leukocyte-platelet-rich plasma improve tendon healing in arthroscopic repair of large or massive rotator cuff tears?

    PubMed

    Charousset, Christophe; Zaoui, Amine; Bellaïche, Laurence; Piterman, Michel

    2014-04-01

    To evaluate the clinical and magnetic resonance imaging (MRI) outcome of arthroscopic rotator cuff repair with the use of leukocyte-platelet-rich plasma (L-PRP) in patients with large or massive rotator cuff tears. A comparative cohort of patients with large or massive rotator cuff tears undergoing arthroscopic repair was studied. Two consecutive groups of patients were included: rotator cuff repairs with L-PRP injection (group 1, n = 35) and rotator cuff repairs without L-PRP injection (group 2, n = 35). A double-row cross-suture cuff repair was performed by a single surgeon with the same rehabilitation protocol. Patients were clinically evaluated with the Constant score; Simple Shoulder Test score; University of California, Los Angeles (UCLA) score; and strength measurements by use of a handheld dynamometer. Rotator cuff healing was evaluated by postoperative MRI using the Sugaya classification (type 1 to type 5). We prospectively evaluated the 2 groups at a minimum 2-year follow-up. The results did not show differences in cuff healing between the 2 groups (P = .16). The size of recurrent tears (type 4 v type 5), however, was significantly smaller in group 1 (P = .008). There was no statistically significant difference in the recurrent tear rate (types 4 and 5) between the 2 groups (P = .65). There was no significant difference between group 1 and group 2 in terms of University of California, Los Angeles score (29.1 and 30.3, respectively; P = .90); Simple Shoulder Test score (9.9 and 10.2, respectively; P = .94); Constant score (77.3 and 78.1, respectively; P = .82); and strength (7.5 and 7.0, respectively; P = .51). In our study the use of autologous L-PRP did not improve the quality of tendon healing in patients undergoing arthroscopic repair of large or massive rotator cuff tears based on postoperative MRI evaluation. The only significant advantage was that the L-PRP patients had smaller iterative tears. However, the functional outcome was similar in the 2 groups of patients. Level III, case-control study. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. The Test Case of HD 26965: Difficulties Disentangling Weak Doppler Signals from Stellar Activity

    NASA Astrophysics Data System (ADS)

    Díaz, Matías R.; Jenkins, James S.; Tuomi, Mikko; Butler, R. Paul; Soto, Maritza G.; Teske, Johanna K.; Feng, Fabo; Shectman, Stephen A.; Arriagada, Pamela; Crane, Jeffrey D.; Thompson, Ian B.; Vogt, Steven S.

    2018-03-01

    We report the discovery of a radial velocity signal that can be interpreted as a planetary-mass candidate orbiting the K dwarf HD 26965, with an orbital period of 42.364 ± 0.015 days, or alternatively, as the presence of residual, uncorrected rotational activity in the data. Observations include data from HIRES, PFS, CHIRON, and HARPS, where 1111 measurements were made over 16 years. Our best solution for HD 26965 b is consistent with a super-Earth that has a minimum mass of 6.92 ± 0.79 {M}\\oplus orbiting at a distance of 0.215 ± 0.008 au from its host star. We have analyzed the correlation between spectral activity indicators and the radial velocities from each instrument, showing moderate correlations that we include in our model. From this analysis, we recover a ∼38-day signal, which matches some literature values of the stellar rotation period. However, from independent Mt. Wilson HK data for this star, we find evidence for a significant 42-day signal after subtraction of longer period magnetic cycles, casting doubt on the planetary hypothesis for this period. Although our statistical model strongly suggests that the 42-day signal is Doppler in origin, we conclude that the residual effects of stellar rotation are difficult to fully model and remove from this data set, highlighting the difficulties to disentangle small planetary signals and photospheric noise, particularly when the orbital periods are close to the rotation period of the star. This study serves as an excellent test case for future works that aim to detect small planets orbiting “Sun-like” stars using radial velocity measurements. Some of the data presented herein were obtained at the W.M. Keck Observatory, which is operated as a scientific partnership among the California Institute of Technology, the University of California, and the National Aeronautics and Space Administration. The Observatory was made possible by the generous financial support of the W.M. Keck Foundation.

  7. Mechanical stability of the subtalar joint after lateral ligament sectioning and ankle brace application: a biomechanical experimental study.

    PubMed

    Kamiya, Tomoaki; Kura, Hideji; Suzuki, Daisuke; Uchiyama, Eiichi; Fujimiya, Mineko; Yamashita, Toshihiko

    2009-12-01

    The roles of each ligament supporting the subtalar joint have not been clarified despite several biomechanical studies. The effects of ankle braces on subtalar instability have not been shown. The ankle brace has a partial effect on restricting excessive motion of the subtalar joint. Controlled laboratory study. Ten normal fresh-frozen cadaveric specimens were used. The angular motions of the talus were measured via a magnetic tracking system. The specimens were tested while inversion and eversion forces, as well as internal and external rotation torques, were applied. The calcaneofibular ligament, cervical ligament, and interosseous talocalcaneal ligament were sectioned sequentially, and the roles of each ligament, as well as the stabilizing effects of the ankle brace, were examined. Complete sectioning of the ligaments increased the angle between the talus and calcaneus in the frontal plane to 51.7 degrees + or - 11.8 degrees compared with 35.7 degrees + or - 6.0 degrees in the intact state when inversion force was applied. There was a statistically significant difference in the angles between complete sectioning of the ligaments and after application of the brace (34.1 degrees + or - 7.3 degrees ) when inversion force was applied. On the other hand, significant differences in subtalar rotation were not found between complete sectioning of the ligaments and application of the brace when internal and external rotational torques were applied. The ankle brace limited inversion of the subtalar joint, but it did not restrict motion after application of internal or external rotational torques. In cases of severe ankle sprains involving the calcaneofibular ligament, cervical ligament, and interosseous talocalcaneal ligament injuries, application of an ankle brace might be less effective in limiting internal-external rotational instabilities than in cases of inversion instabilities in the subtalar joint. An improvement in the design of the brace is needed to restore better rotational stability in the subtalar joint.

  8. Compressible Analysis of Bénard Convection of Magneto Rotatory Couple-Stress Fluid

    NASA Astrophysics Data System (ADS)

    Mehta, C. B.; Singh, M.

    2018-02-01

    Thermal Instability (Benard's Convection) in the presence of uniform rotation and uniform magnetic field (separately) is studied. Using the linearized stability theory and normal mode analyses the dispersion relation is obtained in each case. In the case of rotatory Benard's stationary convection compressibility and rotation postpone the onset of convection whereas the couple-stress have duel character onset of convection depending on rotation parameter. While in the absence of rotation couple-stress always postpones the onset of convection. On the other hand, magnetic field on thermal instability problem on couple-stress fluid for stationary convection couple-stress parameter and magnetic field postpones the onset of convection. The effect of compressibility also postpones the onset of convection in both cases as rotation and magnetic field. Graphs have been plotted by giving numerical values to the parameters to depict the stationary characteristics. Further, the magnetic field and rotation are found to introduce oscillatory modes which were non-existent in their absence and then the principle of exchange of stability is valid. The sufficient conditions for non-existence of overstability are also obtained.

  9. Exploratory Bi-factor Analysis: The Oblique Case.

    PubMed

    Jennrich, Robert I; Bentler, Peter M

    2012-07-01

    Bi-factor analysis is a form of confirmatory factor analysis originally introduced by Holzinger and Swineford (Psychometrika 47:41-54, 1937). The bi-factor model has a general factor, a number of group factors, and an explicit bi-factor structure. Jennrich and Bentler (Psychometrika 76:537-549, 2011) introduced an exploratory form of bi-factor analysis that does not require one to provide an explicit bi-factor structure a priori. They use exploratory factor analysis and a bifactor rotation criterion designed to produce a rotated loading matrix that has an approximate bi-factor structure. Among other things this can be used as an aid in finding an explicit bi-factor structure for use in a confirmatory bi-factor analysis. They considered only orthogonal rotation. The purpose of this paper is to consider oblique rotation and to compare it to orthogonal rotation. Because there are many more oblique rotations of an initial loading matrix than orthogonal rotations, one expects the oblique results to approximate a bi-factor structure better than orthogonal rotations and this is indeed the case. A surprising result arises when oblique bi-factor rotation methods are applied to ideal data.

  10. Shoulder dislocation in patients older than 60 years of age

    PubMed Central

    Rapariz, Jose M.; Martin-Martin, Silvia; Pareja-Bezares, Antonio; Ortega-Klein, Jose

    2010-01-01

    Purpose: Recurrent anterior shoulder dislocation in elderly patients is a little studied condition. The goal of this paper is to clarify the role of associated injuries with respect to loss of function and recurrence of dislocation. Materials and Methods: We have conducted a retrospective, descriptive study on 29 patients older than 60 years at the moment they suffered their first dislocation episode. All patients were assessed clinically (Constant test) and by imaging testing (X-ray, MRI). Results: Nine (31.03%) out of 29 patients had a recurrent dislocation. Four of them required reconstructive surgery to maintain joint stability. Injury to the anterior support (anterior labrum, anterior glenoid rim) showed a statistically significant relation to the recurrence of dislocations. The occurrence or non-occurrence of a rotator cuff tear does have an impact on the shoulder function. The degree of rotator cuff involvement on the coronal plane does not significantly affect the shoulder’s functional outcome. The tear extension on the sagittal plane does cause impairment on the Constant test. Conclusions: Labrum and/or anterior glenoid involvement should be suspected in elderly patients presenting with recurrent shoulder dislocation. Recurrence is due to an injury in the anterior support or both (anterior and posterior), even though shoulder function gets impaired when a rotation cuff tear occurs with anterior extension on the sagittal plane. Evidence level: IV Case series. PMID:21655003

  11. Modal testing of a rotating wind turbine

    NASA Astrophysics Data System (ADS)

    Carne, T. G.; Nord, A. R.

    1982-11-01

    A testing technique was developed to measure the modes of vibration of a rotating vertical-axis wind turbine. This technique was applied to the Sandia Two-Meter Turbine, where the changes in individual modal frequencies as a function of the rotational speed were tracked from 0 rpm (parked) to 600 rpm. During rotational testing, the structural response was measured using a combination of strain gages and accelerometers, passing the signals through slip rings. Excitation of the turbine structure was provided by a scheme which suddenly released a pretensioned cable, thus plucking the turbine as it was rotating at a set speed. In addition to calculating the real modes of the parked turbine, the modes of the rotating turbine were also determined at several rotational speeds. The modes of the rotating system proved to be complex due to centrifugal and Coriolis effects. The modal data for the parked turbine were used to update a finite-element model. Also, the measured modal parameters for the rotating turbine were compared to the analytical results, thus verifying the analytical procedures used to incorporate the effects of the rotating coordinate system.

  12. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT.

    PubMed

    Montoya, J C; Li, Y; Strother, C; Chen, G-H

    2018-05-01

    Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose. A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts. Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies. Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure required to obtain clinically useful 3D rotational angiography. © 2018 by American Journal of Neuroradiology.

  13. Three-dimensional volume-rendering technique in the angiographic follow-up of intracranial aneurysms embolized with coils.

    PubMed

    Zhou, Bing; Li, Ming-Hua; Wang, Wu; Xu, Hao-Wen; Cheng, Yong-De; Wang, Jue

    2010-03-01

    The authors conducted a study to evaluate the advantages of a 3D volume-rendering technique (VRT) in follow-up digital subtraction (DS) angiography of coil-embolized intracranial aneurysms. One hundred nine patients with 121 intracranial aneurysms underwent endovascular coil embolization and at least 1 follow-up DS angiography session at the authors' institution. Two neuroradiologists independently evaluated the conventional 2D DS angiograms, rotational angiograms, and 3D VRT images obtained at the interventional procedures and DS angiography follow-up. If multiple follow-up sessions were performed, the final follow-up was mainly considered. The authors compared the 3 techniques for their ability to detect aneurysm remnants (including aneurysm neck and sac remnants) and parent artery stenosis based on the angiographic follow-up. The Kruskal-Wallis test was used for group comparisons, and the kappa test was used to measure interobserver agreement. Statistical analyses were performed using commercially available software. There was a high statistical significance among 2D DS angiography, rotational angiography, and 3D VRT results (X(2) = 9.9613, p = 0.0069) when detecting an aneurysm remnant. Further comparisons disclosed a statistical significance between 3D VRT and rotational angiography (X(2) = 4.9754, p = 0.0257); a high statistical significance between 3D VRT and 2D DS angiography (X(2) = 8.9169, p = 0.0028); and no significant difference between rotational angiography and 2D DS angiography (X(2) = 0.5648, p = 0.4523). There was no statistical significance among the 3 techniques when detecting parent artery stenosis (X(2) = 2.5164, p = 0.2842). One case, in which parent artery stenosis was diagnosed by 2D DS angiography and rotational angiography, was excluded by 3D VRT following observations of multiple views. The kappa test showed good agreement between the 2 observers. The 3D VRT is more sensitive in detecting aneurysm remnants than 2D DS angiography and rotational angiography and is helpful for identifying parent artery stenosis. The authors recommend this technique for the angiographic follow-up of patients with coil-embolized aneurysms.

  14. Turbine and method for reducing shock losses in a turbine

    DOEpatents

    Ristau, Neil

    2015-09-01

    A turbine includes a rotor and a casing that circumferentially surrounds at least a portion of the rotor. The rotor and the casing at least partially define a gas path through the turbine. A last stage of rotating blades is circumferentially arranged around the rotor and includes a downstream swept portion radially outward from the rotor. A method for reducing shock losses in a turbine includes removing a last stage of rotating blades circumferentially arranged around a rotor and replacing the last stage of rotating blades with rotating blades having a downstream swept portion radially outward from the rotor.

  15. Reynolds number dependency of an insect-based flapping wing.

    PubMed

    Han, Jong-Seob; Chang, Jo-Won; Kim, Sun-Tae

    2014-01-01

    Aerodynamic characteristics depending on Reynolds number (Re) ranges were studied to investigate the suitable design parameters of an insect-based micro air vehicle (MAV). The tests centered on the wing rotation timing and Re ranges, and were conducted to understand the lift augmentations and unsteady effects. A dynamically scaled-up flapping wing controlled by a pair of servos was installed underwater with a micro force/torque sensor. A high-speed camera and a laser sheet were also put in front of the water tank for the time-resolved digital particle image velocimetry (DPIV). The lift augmentations clearly appeared at low Re and were well reflected on the insect's flight range. In the case of the high Re, however, the peak standing for the wing–wake interaction was delayed, and the pitching-up rotation was not able to lead to another lift enhancement, i.e., rotational lift. In such Re, the mean CL and the L/D of the advanced rotation were substantially decreased from those of the other rotations. The DPIV results at high Re well described turbulent characteristics such as the irregular, unstable, and high-intensity vortex structures with a short temporal delay. In the advanced rotation, the LEV in the rotational phase could not maintain the attachment. Thus, the rotational lift was not able to work. On the contrary, the temporal response delay benefitted the wing in the delayed rotation. Therefore, the wing in the delayed rotation had both a similar level of the mean CL and a higher marked L/D than those of the advanced rotation. Such results indicate that the high Re could interrupt lift augmentation mechanisms, and these augmentations would not be suitable for a heavier MAV. In conclusion, using adequate wing kinematics to acquire estimations of the weight and range of the Re is highly recommended at the aerodynamic design step.

  16. Relationship between Spatial Abilities, Mental Rotation and Functional Anatomy Learning

    ERIC Educational Resources Information Center

    Guillot, Aymeric; Champely, Stephane; Batier, Christophe; Thiriet, Patrice; Collet, Christian

    2007-01-01

    This study investigated the relationship between visuo-spatial representation, mental rotation (MR) and functional anatomy examination results. A total of 184 students completed the Group Embedded Figures Test (GEFT), Mental Rotation Test (MRT) and Gordon Test of Visual Imagery Control. The time spent on personal assignment was also considered.…

  17. Motion Controllers for Learners to Manipulate and Interact with 3D Objects for Mental Rotation Training

    ERIC Educational Resources Information Center

    Yeh, Shih-Ching; Wang, Jin-Liang; Wang, Chin-Yeh; Lin, Po-Han; Chen, Gwo-Dong; Rizzo, Albert

    2014-01-01

    Mental rotation is an important spatial processing ability and an important element in intelligence tests. However, the majority of past attempts at training mental rotation have used paper-and-pencil tests or digital images. This study proposes an innovative mental rotation training approach using magnetic motion controllers to allow learners to…

  18. Video Head Impulse Testing (vHIT) and the Assessment of Horizontal Semicircular Canal Function.

    PubMed

    Riska, Kristal M; Murnane, Owen; Akin, Faith W; Hall, Courtney

    2015-05-01

    Vestibular function (specifically, horizontal semicircular canal function) can be assessed across a broad frequency range using several different techniques. The head impulse test is a qualitative test of horizontal semicircular canal function that can be completed at bedside. Recently, a new instrument (video head impulse test [vHIT]) has been developed to provide an objective assessment to the clinical test. Questions persist regarding how this test may be used in the overall vestibular test battery. The purpose of this case report is to describe vestibular test results (vHIT, rotational testing, vestibular evoked myogenic potentials, and balance and gait performance) in an individual with a 100% unilateral caloric weakness who was asymptomatic for dizziness, vertigo or imbalance. Comprehensive assessment was completed to evaluate vestibular function. Caloric irrigations, rotary chair testing, vHIT, and vestibular evoked myogenic potentials were completed. A 100% left-sided unilateral caloric weakness was observed in an asymptomatic individual. vHIT produced normal gain with covert saccades. This case demonstrates the clinical usefulness of vHIT as a diagnostic tool and indicator of vestibular compensation and functional status. American Academy of Audiology.

  19. A generalized rotationally symmetric case of the centroaffine Minkowski problem

    NASA Astrophysics Data System (ADS)

    Lu, Jian

    2018-05-01

    In this paper the centroaffine Minkowski problem, a critical case of the Lp-Minkowski problem in the n + 1 dimensional Euclidean space, is studied. By its variational structure and the method of blow-up analyses, we obtain two sufficient conditions for the existence of solutions, for a generalized rotationally symmetric case of the problem.

  20. Misperceptions of angular velocities influence the perception of rigidity in the kinetic depth effect

    NASA Technical Reports Server (NTRS)

    Domini, F.; Caudek, C.; Proffitt, D. R.; Kaiser, M. K. (Principal Investigator)

    1997-01-01

    Accuracy in discriminating rigid from nonrigid motion was investigated for orthographic projections of three-dimension rotating objects. In 3 experiments the hypothesis that magnitudes of angular velocity are misperceived in the kinetic depth effect was tested, and in 4 other experiments the hypothesis that misperceiving angular velocities leads to misperceiving rigidity was tested. The principal findings were (a) the magnitude of perceived angular velocity is derived heuristically as a function of a property of the first-order optic flow called deformation and (b) perceptual performance in discriminating rigid from nonrigid motion is accurate in cases when the variability of the deformations of the individual triplets of points of the stimulus displays favors this interpretation and not accurate in other cases.

  1. Misperceptions of angular velocities influence the perception of rigidity in the kinetic depth effect.

    PubMed

    Domini, F; Caudek, C; Proffitt, D R

    1997-08-01

    Accuracy in discriminating rigid from nonrigid motion was investigated for orthographic projections of three-dimension rotating objects. In 3 experiments the hypothesis that magnitudes of angular velocity are misperceived in the kinetic depth effect was tested, and in 4 other experiments the hypothesis that misperceiving angular velocities leads to misperceiving rigidity was tested. The principal findings were (a) the magnitude of perceived angular velocity is derived heuristically as a function of a property of the first-order optic flow called deformation and (b) perceptual performance in discriminating rigid from nonrigid motion is accurate in cases when the variability of the deformations of the individual triplets of points of the stimulus displays favors this interpretation and not accurate in other cases.

  2. Whirl measurements on leakage flows in turbomachine models

    NASA Technical Reports Server (NTRS)

    Addlesee, A. J.; Altiparmak, D.; Pan, S.

    1994-01-01

    The beneficial effects claimed for whirl control devices demonstrate that the dynamic behavior of rotors is influenced by the fluid whirl in shaft and balance drum seals. The present paper reports results from two series of experiments, the first on the factors affecting the whirl at the seal inlet, and the second on the variation of whirl velocity along the seal. In both cases the LDA measurement technique required the clearance between the fixed and rotating parts of the models to be substantially greater than occurs in real machines, but the results are indicative nevertheless. Experimental and theoretical results are given for the radial distribution of whirl velocity in the gap between impeller shroud and pump casing. Results of tests with modified stator surfaces are also shown. This work leads naturally into the second series of experiments where some preliminary measurements of velocity distribution in the clearance between a fixed stator and a rotating shaft are reported for a range of inlet whirl conditions.

  3. Effect of tibial positioning on the diagnosis of posterolateral rotatory instability in the posterior cruciate ligament-deficient knee.

    PubMed

    Strauss, Eric J; Ishak, Charbel; Inzerillo, Christopher; Walsh, Michael; Yildirim, Gokce; Walker, Peter; Jazrawi, Laith; Rosen, Jeffrey

    2007-08-01

    To determine whether positioning of the tibia affects the degree of tibial external rotation seen during a dial test in the posterior cruciate ligament (PCL)-posterolateral corner (PLC)-deficient knee. Laboratory investigation. Biomechanics laboratory. An anterior force applied to the tibia in the combined PCL-PLC-deficient knee will yield increased tibial external rotation during a dial test. The degree of tibial external rotation was measured with 5 Nm of external rotation torque applied to the tibia at both 30 degrees and 90 degrees of knee flexion. Before the torque was applied, an anterior force, a posterior force, or neutral (normal, reduced control) force was applied to the tibia. External rotation measurements were repeated after sequential sectioning of the PCL, the posterolateral structures and the fibular collateral ligament (FCL). Baseline testing of the intact specimens demonstrated a mean external rotation of 18.6 degrees with the knee flexed to 30 degrees (range 16.1-21.0 degrees ), and a mean external rotation of 17.3 degrees with the knee flexed to 90 degrees (range 13.8-20.0 degrees ). Sequential sectioning of the PCL, popliteus and popliteofibular ligament, and the FCL led to a significant increase in tibial external rotation compared with the intact knee for all testing scenarios. After sectioning of the popliteus and popliteofibular ligament, the application of an anterior force during testing led to a mean tibial external rotation that was 5 degrees greater than during testing in the neutral position and 7.5 degrees greater than during testing with a posterior force. In the PCL, popliteus/popliteofibular ligament and FCL-deficient knee, external rotation was 9 degrees and 12 degrees greater with the application of an anterior force during testing compared with neutral positioning and the application of a posterior force, respectively. An anterior force applied to the tibia during the dial test in a combined PCL-PLC-injured knee increased the overall amount of observed tibial external rotation during the dial test. The anterior force reduced the posterior tibial subluxation associated with PCL injury, which is analogous to what is observed when the dial test is performed with the patient in the prone position. Reducing the tibia with either an anterior force when the patient is supine or performing the dial test with the patient in the prone position increases the ability of an examiner to detect a concomitant PLC injury in the setting of a PCL-deficient knee.

  4. The use of a robotic tibial rotation device and an electromagnetic tracking system to accurately reproduce the clinical dial test.

    PubMed

    Stinton, S K; Siebold, R; Freedberg, H; Jacobs, C; Branch, T P

    2016-03-01

    The purpose of this study was to: (1) determine whether a robotic tibial rotation device and an electromagnetic tracking system could accurately reproduce the clinical dial test at 30° of knee flexion; (2) compare rotation data captured at the footplates of the robotic device to tibial rotation data measured using an electromagnetic sensor on the proximal tibia. Thirty-two unilateral ACL-reconstructed patients were examined using a robotic tibial rotation device that mimicked the dial test. The data reported in this study is only from the healthy legs of these patients. Torque was applied through footplates and was measured using servomotors. Lower leg motion was measured at the foot using the motors. Tibial motion was also measured through an electromagnetic tracking system and a sensor on the proximal tibia. Load-deformation curves representing rotational motion of the foot and tibia were compared using Pearson's correlation coefficients. Off-axis motions including medial-lateral translation and anterior-posterior translation were also measured using the electromagnetic system. The robotic device and electromagnetic system were able to provide axial rotation data and translational data for the tibia during the dial test. Motion measured at the foot was not correlated to motion of the tibial tubercle in internal rotation or in external rotation. The position of the tibial tubercle was 26.9° ± 11.6° more internally rotated than the foot at torque 0 Nm. Medial-lateral translation and anterior-posterior translation were combined to show the path of the tubercle in the coronal plane during tibial rotation. The information captured during a manual dial test includes both rotation of the tibia and proximal tibia translation. All of this information can be captured using a robotic tibial axial rotation device with an electromagnetic tracking system. The pathway of the tibial tubercle during tibial axial rotation can provide additional information about knee instability without relying on side-to-side comparison between knees. The translation of the proximal tibia is important information that must be considered in addition to axial rotation of the tibia when performing a dial test whether done manually or with a robotic device. Instrumented foot position cannot provide the same information. IV.

  5. Behavior of a test gyroscope moving towards a rotating traversable wormhole

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chakraborty, Chandrachur; Pradhan, Parthapratim, E-mail: chandrachur.chakraborty@tifr.res.in, E-mail: pppradhan77@gmail.com

    2017-03-01

    The geodesic structure of the Teo wormhole is briefly discussed and some observables are derived that promise to be of use in detecting a rotating traversable wormhole indirectly, if it does exist. We also deduce the exact Lense-Thirring (LT) precession frequency of a test gyroscope moving toward a rotating traversable Teo wormhole. The precession frequency diverges on the ergoregion, a behavior intimately related to and governed by the geometry of the ergoregion, analogous to the situation in a Kerr spacetime. Interestingly, it turns out that here the LT precession is inversely proportional to the angular momentum ( a ) ofmore » the wormhole along the pole and around it in the strong gravity regime, a behavior contrasting with its direct variation with a in the case of other compact objects. In fact, divergence of LT precession inside the ergoregion can also be avoided if the gyro moves with a non-zero angular velocity in a certain range. As a result, the spin precession frequency of the gyro can be made finite throughout its whole path, even very close to the throat, during its travel to the wormhole. Furthermore, it is evident from our formulation that this spin precession not only arises due to curvature or rotation of the spacetime but also due to the non-zero angular velocity of the spin when it does not move along a geodesic in the strong gravity regime. If in the future, interstellar travel indeed becomes possible through a wormhole or at least in its vicinity, our results would prove useful in determining the behavior of a test gyroscope which is known to serve as a fundamental navigation device.« less

  6. Numerical Simulation of the Borehole Magnetic Field for Resolving the Possible Rotation of Tectonic Basins and Plates during ICDP and IODP Experiments

    NASA Astrophysics Data System (ADS)

    Lee, S. M.; Parq, J. H.

    2017-12-01

    An accurate measurement of magnetic field inside the borehole, together with a right set of paleomagnetic measurements on the recovered core samples, should allow one to resolve important elements such as the rotation of the basin or the plate on which the basin is located. The ability to resolve the rotation of the basin can be crucial during drilling experiments by International Continental Scientific Drilling Program (ICDP) and International Ocean Discovery Program (IODP). A good example where the rotation is a central question is the Philippine Sea Plate, which is thought to have rotated about 90° clockwise during the last 55 million years. Despite the significance, previous borehole magnetometers were not accurate enough to achieve such a goal because, among various technical issues, determining the orientation of the sensor inside the borehole to a very high level of accuracy was not easy. The next-generation (third-generation) borehole magnetometer (3GBM) was developed to overcome this difficulty and to bring paleomagnetic investigations to a new level. Even with the new development, however, there are still concerns whether the new instrument can really resolve the rotation because the magnetic field anomalies generated by the sediment is generally very low. In this paper, we present numerical simulations based on finite element method of the magnetic field inside the borehole that were conducted as part of a test to demonstrate that, despite low levels of magnetization, the magnetic fields can be resolved. The results also served as an important input on the design requirements of the borehole magnetometer. Various cases were considered, including the situation where the sedimentary layer is horizontal and inclined. We also explored the cases where volcanic sills were present within the sedimentary layer as they may provide a greater magnetic signature than having sediment alone, and thus improving our chances of determining the rotation. Simulations are necessary because they provide us useful guidelines for planning a future drill experiment as well as on the first-hand interpretation of the borehole measurement results.

  7. Prognostic Factors Affecting Rotator Cuff Healing After Arthroscopic Repair in Small to Medium-sized Tears.

    PubMed

    Park, Ji Soon; Park, Hyung Jun; Kim, Sae Hoon; Oh, Joo Han

    2015-10-01

    Small and medium-sized rotator cuff tears usually have good clinical and anatomic outcomes. However, healing failure still occurs in some cases. To evaluate prognostic factors for rotator cuff healing in patients with only small to medium-sized rotator cuff tears. Case-control study; Level of evidence, 3. Data were prospectively collected from 339 patients with small to medium-sized rotator cuff tears who underwent arthroscopic repair by a single surgeon between March 2004 and August 2012 and who underwent magnetic resonance imaging or computed tomographic arthrography at least 1 year after surgery. The mean age of the patients was 59.8 years (range, 39-80 years), and the mean follow-up time was 20.8 months (range, 12-66 months). The functional evaluation included the visual analog scale (VAS) for pain, American Shoulder and Elbow Surgeons score, Constant-Murley score, and Simple Shoulder Test. Postoperative VAS for pain and functional scores improved significantly compared with preoperative values (P < .001). Forty-five healing failures occurred (13.3%), and fatty degeneration of the infraspinatus muscle, tear size (anteroposterior dimension), and age were significant factors affecting rotator cuff healing (P < .001, = .018, and = .011, respectively) in multivariate logistic regression analysis. Grade II and higher infraspinatus fatty degeneration correlated with a higher failure rate. The failure rate was also significantly higher in patients with a tear >2 cm in size (34.2%) compared with patients with a tear ≤2 cm (10.6%) (P < .001). A receiver operating characteristic curve was used to determine the predictive cut-off value for the oldest age and the largest tear size for successful healing, which were calculated as 69 years and 2 cm, respectively, with a specificity of 90%. In small to medium-sized rotator cuff tears, grade II fatty degeneration of the infraspinatus muscle according to the Goutallier classification could be a reference point for successful healing, and anatomic outcomes might be better if repair is performed before the patient is 69 years old and the tear size exceeds 2 cm. © 2015 The Author(s).

  8. Design and Testing of an H2/O2 Predetonator for a Simulated Rotating Detonation Engine Channel

    DTIC Science & Technology

    2013-03-01

    Diameter PDE Pulse Detonation Engines RDE Rotating Detonation Engine WPAFB Wright Patterson Air Force Base ZND Zeldovich, von Neumann and Doring xv...DESIGN AND TESTING OF AN H2/O2 PREDETONATOR FOR A SIMULATED ROTATING DETONATION ENGINE CHANNEL THESIS Stephen J. Miller, 2Lt, USAF AFIT-ENY-13-M-23...RELEASE; DISTRIBUTION UNLIMITED AFIT-ENY-13-M-23 DESIGN AND TESTING OF AN H2/O2 PREDETONATOR FOR A SIMULATED ROTATING DETONATION ENGINE CHANNEL Stephen

  9. Test Plan for SSR Antenna Rotation Rate Stabilization

    DOT National Transportation Integrated Search

    1981-10-01

    A comprehensive test plan is presented to evaluate the impact of wind and ice loading on the rotation rate stability of a Secondary Surveillance Radar (SSR) antenna used for air traffic control surveillance. Antenna rotation rate variations may intro...

  10. Some experiments on Yaw stability of wind turbines with various coning angles

    NASA Technical Reports Server (NTRS)

    Bundas, D.; Dugundji, J.

    1981-01-01

    A horizontal axis wind turbine was constructed to study the effect of coning angle on the yawing moments produced. Coning angles of 0 deg, +10 deg and -10 deg were studied in the upwind and downwind cases. Moment and rotational frequency of the blades at each yaw angle setting were taken. It was found that as the coning angle increased from -10 deg to +10 deg in either the upwind or downwind case the stability decreased. The downwind case was slightly more stable for all coning angles than was the upwind case. It is found that all the previous cases were stable for high rotation speeds, but at lower rotation speeds, they were all unstable and could not self start unless held in the wind.

  11. Users' manual for the Langley high speed propeller noise prediction program (DFP-ATP)

    NASA Technical Reports Server (NTRS)

    Dunn, M. H.; Tarkenton, G. M.

    1989-01-01

    The use of the Dunn-Farassat-Padula Advanced Technology Propeller (DFP-ATP) noise prediction program which computes the periodic acoustic pressure signature and spectrum generated by propellers moving with supersonic helical tip speeds is described. The program has the capacity of predicting noise produced by a single-rotation propeller (SRP) or a counter-rotation propeller (CRP) system with steady or unsteady blade loading. The computational method is based on two theoretical formulations developed by Farassat. One formulation is appropriate for subsonic sources, and the other for transonic or supersonic sources. Detailed descriptions of user input, program output, and two test cases are presented, as well as brief discussions of the theoretical formulations and computational algorithms employed.

  12. The impact of rotator cuff tendinopathy on proprioception, measuring force sensation.

    PubMed

    Maenhout, Annelies G; Palmans, Tanneke; De Muynck, Martine; De Wilde, Lieven F; Cools, Ann M

    2012-08-01

    The impact of rotator cuff tendinopathy and related impingement on proprioception is not well understood. Numerous quantitative and qualitative changes in shoulder muscles have been shown in patients with rotator cuff tendinopathy. These findings suggest that control of force might be affected. This investigation wants to evaluate force sensation, a submodality of proprioception, in patients with rotator cuff tendinopathy. Thirty-six patients with rotator cuff tendinopathy and 30 matched healthy subjects performed force reproduction tests to isometric external and internal rotation to investigate how accurately they could reproduce a fixed target (50% MVC). Relative error, constant error, and force steadiness were calculated to evaluate respectively magnitude of error made during the test, direction of this error (overshoot or undershoot), and fluctuations of produced forces. Patients significantly overshoot the target (mean, 6.04% of target) while healthy subjects underestimate the target (mean, -5.76% of target). Relative error and force steadiness are similar in patients with rotator cuff tendinopathy and healthy subjects. Force reproduction tests, as executed in this study, were found to be highly reliable (ICC 0.849 and 0.909). Errors were significantly larger during external rotation tests, compared to internal rotation. Patients overestimate the target during force reproduction tests. This should be taken into account in the rehabilitation of patients with rotator cuff tendinopathy; however, precision of force sensation and steadiness of force exertion remains unaltered. This might indicate that control of muscle force is preserved. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  13. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    PubMed

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally, the combination of MR imaging and clinical tests does not improve diagnostic accuracy. Level II, Diagnostic study.

  14. Pixel-based absolute surface metrology by three flat test with shifted and rotated maps

    NASA Astrophysics Data System (ADS)

    Zhai, Dede; Chen, Shanyong; Xue, Shuai; Yin, Ziqiang

    2018-03-01

    In traditional three flat test, it only provides the absolute profile along one surface diameter. In this paper, an absolute testing algorithm based on shift-rotation with three flat test has been proposed to reconstruct two-dimensional surface exactly. Pitch and yaw error during shift procedure is analyzed and compensated in our method. Compared with multi-rotation method proposed before, it only needs a 90° rotation and a shift, which is easy to carry out especially in condition of large size surface. It allows pixel level spatial resolution to be achieved without interpolation or assumption to the test surface. In addition, numerical simulations and optical tests are implemented and show the high accuracy recovery capability of the proposed method.

  15. Anatomical landmarks of the distal femoral condyles are not always parallel to the tibial bone cut surface in flexion during total knee arthroplasty.

    PubMed

    Itokazu, Maki; Minoda, Yukihide; Ikebuchi, Mitsuhiko; Mizokawa, Shigekazu; Ohta, Yoichi; Nakamura, Hiroaki

    2016-08-01

    Soft tissue balancing is crucial to the success of total knee arthroplasty (TKA). To create a rectangular flexion joint gap, the rotation of the femoral component is important. The purpose of this study is to determine whether or not anatomical landmarks of the distal femoral condyles are parallel to the tibial bone cut surface in flexion. Forty-eight patients (three male and 45 female) with a mean age of 74years were examined. During the operation, we estimated the flexion joint gap with the following three techniques. 1) a three degree external cut to the posterior condylar line (MR1), 2) a parallel cut to the surgical transepicondylar axis (MR2), and 3) a parallel cut to the anatomical transepicondylar axis (MR3). The flexion joint gap was 1.1±3.0° (mean±standard deviation (SD)) in internal rotation in the case of MR1, 0.9±3.4° in internal rotation in the case of MR2, and 2.1±3.4° in external rotation in the case of MR3. An outlier (flexion joint gap >3.0°) was observed in 12 cases (25%) in MR1, 13 cases (27%) in MR2, and 15 cases (31%) in MR3. The anatomical landmarks of the distal femoral condyles are not always parallel to the tibial bone cut surface in flexion. To create a rectangular flexion joint gap, the rotation of the femoral component rotation is based not only on the anatomical landmarks but also on the ligament balance. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Mental rotation and the human body: Children's inflexible use of embodiment mirrors that of adults.

    PubMed

    Krüger, Markus; Ebersbach, Mirjam

    2017-12-25

    Adults' mental rotation performance with body-like stimuli is enhanced if these stimuli are anatomically compatible with a human body, but decreased by anatomically incompatible stimuli. In this study, we investigated these effects for kindergartners and first-graders: When asked to mentally rotate cube configurations attached with human body parts in an anatomically compatible way, allowing for the projection of a human body, children performed better than with pure cube combinations. By contrast, when body parts were attached in an anatomically incompatible way, disallowing the projection of a human body, children performed worse than with pure combinations. This experiment is of specific interest against the background of two different theoretical approaches concerning imagery and the motor system in development: One approach assumes an increasing integration of motor processes and imagery over time that enables older children and adults to requisition motor resources for imagery processes, while the other postulates that imagery stems from early sensorimotor processes in the first place, and is disentangled from it over time. The finding that children of the two age groups tested show exactly the same effects as adults when mentally rotating anatomically compatible and incompatible stimuli is interpreted in favour of the latter approach. Statement of contribution What is already known on this subject? In mental rotation, adults perform better when rotating anatomically possible stimuli as compared to rotating standard cube combinations. Performance is worse when rotating anatomically impossible stimuli. What does this study add? The present study shows that children's mental transformations mirror those of adults in these respects. In case of the anatomically impossible stimuli, this highlights an inflexible use of embodiment in both age groups. This is in line with the Piagetian assumption of imagery being based on sensorimotor processes. © 2017 The British Psychological Society.

  17. Steady States of the Parametric Rotator and Pendulum

    ERIC Educational Resources Information Center

    Bouzas, Antonio O.

    2010-01-01

    We discuss several steady-state rotation and oscillation modes of the planar parametric rotator and pendulum with damping. We consider a general elliptic trajectory of the suspension point for both rotator and pendulum, for the latter at an arbitrary angle with gravity, with linear and circular trajectories as particular cases. We treat the…

  18. 14 CFR 125.177 - Control of engine rotation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Control of engine rotation. 125.177 Section... Requirements § 125.177 Control of engine rotation. (a) Except as provided in paragraph (b) of this section... flight. (b) In the case of turbine engine installations, a means of stopping rotation need be provided...

  19. Effect of the collector tube profile on Pitot pump performances

    NASA Astrophysics Data System (ADS)

    Komaki, K.; Kanemoto, T.; Sagara, K.; Umekage, T.

    2013-12-01

    The pitot pump is composed of the rotating casing with the impeller channel and the pitot tube type collector as the discharge line. The radial impeller feeds water to the rotating casing. The water rotating together with the casing is caught by the stationary pitot tube type collector, and then discharges to the outside. This type pump, as the extra high head pump, is provided mainly for boiler feed systems, and has been designed by trial and error. To optimize the pump profiles, it is desirable to investigate not only performances but also internal flow conditions. This paper discusses experimentally and numerically the relation between the pump performances and the flow conditions in the rotating casing. The moderately larger dimensions of the collector make the pump head and the discharge high with the higher hydraulic efficiency. The flow in the casing is almost the forced vortex type whose velocity is in proportion to the radius but the core velocity is affected with the drag force of the stationary collector. Based upon the above results, the profile of the pitot tube type collector was optimized with the numerical simulation.

  20. Uniformly rotating, axisymmetric, and triaxial quark stars in general relativity

    NASA Astrophysics Data System (ADS)

    Zhou, Enping; Tsokaros, Antonios; Rezzolla, Luciano; Xu, Renxin; Uryū, Kōji

    2018-01-01

    Quasiequilibrium models of uniformly rotating axisymmetric and triaxial quark stars are computed in a general-relativistic gravity scenario. The Isenberg-Wilson-Mathews (IWM) formulation is employed and the Compact Object Calculator (cocal) code is extended to treat rotating stars with finite surface density and new equations of state (EOSs). Besides the MIT bag model for quark matter which is composed of deconfined quarks, we examine a new EOS proposed by Lai and Xu that is based on quark clustering and results in a stiff EOS that can support masses up to 3.3 M⊙ in the case we considered. We perform convergence tests for our new code to evaluate the effect of finite surface density in the accuracy of our solutions and construct sequences of solutions for both small and high compactness. The onset of secular instability due to viscous dissipation is identified and possible implications are discussed. An estimate of the gravitational wave amplitude and luminosity based on quadrupole formulas is presented and comparison with neutron stars is discussed.

  1. Accurate interatomic force fields via machine learning with covariant kernels

    NASA Astrophysics Data System (ADS)

    Glielmo, Aldo; Sollich, Peter; De Vita, Alessandro

    2017-06-01

    We present a novel scheme to accurately predict atomic forces as vector quantities, rather than sets of scalar components, by Gaussian process (GP) regression. This is based on matrix-valued kernel functions, on which we impose the requirements that the predicted force rotates with the target configuration and is independent of any rotations applied to the configuration database entries. We show that such covariant GP kernels can be obtained by integration over the elements of the rotation group SO (d ) for the relevant dimensionality d . Remarkably, in specific cases the integration can be carried out analytically and yields a conservative force field that can be recast into a pair interaction form. Finally, we show that restricting the integration to a summation over the elements of a finite point group relevant to the target system is sufficient to recover an accurate GP. The accuracy of our kernels in predicting quantum-mechanical forces in real materials is investigated by tests on pure and defective Ni, Fe, and Si crystalline systems.

  2. Parallel Computing of Upwelling in a Rotating Stratified Flow

    NASA Astrophysics Data System (ADS)

    Cui, A.; Street, R. L.

    1997-11-01

    A code for the three-dimensional, unsteady, incompressible, and turbulent flow has been implemented on the IBM SP2, using message passing. The effects of rotation and variable density are included. A finite volume method is used to discretize the Navier-Stokes equations in general curvilinear coordinates on a non-staggered grid. All the spatial derivatives are approximated using second-order central differences with the exception of the convection terms, which are handled with special upwind-difference schemes. The semi-implicit, second-order accurate, time-advancement scheme employs the Adams-Bashforth method for the explicit terms and Crank-Nicolson for the implicit terms. A multigrid method, with the four-color ZEBRA as smoother, is used to solve the Poisson equation for pressure, while the momentum equations are solved with an approximate factorization technique. The code was successfully validated for a variety test cases. Simulations of a laboratory model of coastal upwelling in a rotating annulus are in progress and will be presented.

  3. Deformation and Life Analysis of Composite Flywheel Disk and Multi-disk Systems

    NASA Technical Reports Server (NTRS)

    Arnold, S. M.; Saleeb, A. F.; AlZoubi, N. R.

    2001-01-01

    In this study an attempt is made to put into perspective the problem of a rotating disk, be it a single disk or a number of concentric disks forming a unit. An analytical model capable of performing an elastic stress analysis for single/multiple, annular/solid, anisotropic/isotropic disk systems, subjected to both pressure surface tractions, body forces (in the form of temperature-changes and rotation fields) and interfacial misfits is derived and discussed. Results of an extensive parametric study are presented to clearly define the key design variables and their associated influence. In general the important parameters were identified as misfit, mean radius, thickness, material property and/or load gradation, and speed; all of which must be simultaneously optimized to achieve the "best" and most reliable design. Also, the important issue of defining proper performance/merit indices (based on the specific stored energy), in the presence of multiaxiality and material anisotropy is addressed. These merit indices are then utilized to discuss the difference between flywheels made from PMC and TMC materials with either an annular or solid geometry. Finally two major aspects of failure analysis, that is the static and cyclic limit (burst) speeds are addressed. In the case of static limit loads, upper, lower, and out-of-plane bounds for disks with constant thickness are presented for both the case of internal pressure loading (as one would see in a hydroburst test) and pure rotation (as in the case of a free spinning disk). The results (interaction diagrams) are displayed graphically in designer friendly format. For the case of fatigue, a representative fatigue/life master curve is illustrated in which the normalized limit speed versus number of applied cycles is given for a cladded TMC disk application.

  4. Gravitational instability of slowly rotating isothermal spheres

    NASA Astrophysics Data System (ADS)

    Chavanis, P. H.

    2002-12-01

    We discuss the statistical mechanics of rotating self-gravitating systems by allowing properly for the conservation of angular momentum. We study analytically the case of slowly rotating isothermal spheres by expanding the solutions of the Boltzmann-Poisson equation in a series of Legendre polynomials, adapting the procedure introduced by Chandrasekhar (1933) for distorted polytropes. We show how the classical spiral of Lynden-Bell & Wood (1967) in the temperature-energy plane is deformed by rotation. We find that gravitational instability occurs sooner in the microcanonical ensemble and later in the canonical ensemble. According to standard turning point arguments, the onset of the collapse coincides with the minimum energy or minimum temperature state in the series of equilibria. Interestingly, it happens to be close to the point of maximum flattening. We generalize the singular isothermal solution to the case of a slowly rotating configuration. We also consider slowly rotating configurations of the self-gravitating Fermi gas at non-zero temperature.

  5. Three Investigations of Low Mass Stars in the Milky Way Using New Technology Surveys

    NASA Astrophysics Data System (ADS)

    Lurie, John C.

    At least 80% of stars in the Milky Way have masses less than or equal to the Sun. These long lived stars are the most likely hosts of planets where complex life can develop. Although relatively stable on the timescale of billions of years, many low mass stars possess strong magnetic fields that are manifested in energetic surface activity, which may pose a hazard to both life and technology. Magnetic activity also influences the evolution of a low mass star through a feedback process that slows the rotation rate, which in turn tends to decrease the amount of activity. In this way, the rotation rate and activity level of a low mass star may provide an estimate of its age. Beyond their rotation-activity evolution as isolated objects, a small but important fraction of low mass stars have a close binary companion that influences the rotational and orbital properties of the system. Binary interaction can lead to phenomena such as supernovae, cataclysmic variables, and degenerate object mergers. From a larger perspective, low mass stars trace Galactic structure, and through their longevity serve as archives of the dynamical and chemical history of the Milky Way. Thus a full picture of low mass stars, and by extension the Milky Way, requires understanding their rotation and activity; their interaction in close binaries; and their spatial and kinematic distribution throughout the Galaxy. Historically, these topics have been approached from two separate but complementary modes of observation. Time series photometric surveys measure the stellar variability caused by rotation, activity, and binary interaction, while wide field surveys measure the brightnesses and colors of millions of stars to map their distribution in the Galaxy. The first generation of digital detectors and computing technology limited intensive time series surveys to a small number of stars, and limited wide field surveys to little if any variability information. Today those limitations are falling away. This thesis is composed of three investigations of low mass stars using two recent surveys at the cutting edge of detector technology. The Kepler space telescope carried the largest camera ever launched into space, and continuously monitored the brightnesses of hundreds of thousands of stars with unprecedented precision and cadence. The Pan-STARRS survey was equipped with the largest camera ever constructed, and imaged 75% percent of the sky to greater depth than any previous optical survey. The first investigation in this thesis used Kepler observations of a binary system containing two stars that are about one third the mass of the Sun. The convective motions in these stars extend to their centers, and so there is no interface with a radiative core to drive a solar-like dynamo that powers the magnetic activity of stars like the Sun. By virtue of being in a binary, the stars have the same age, providing a control for the interdependent effects of activity and rotation. The investigation found that the stars have nearly the same level of activity, despite one star rotating almost three times faster than the other. This suggests that in fully convective stars, there is a threshold rotation rate above which activity is no longer correlated with rotation. The second investigation also used Kepler observations, but in this case focused on low mass stars in close binaries, where tidal interactions are expected to circularize the orbit and synchronize the rotation rates to the orbital period. Prior to this investigation, there were few observational constraints on the tidal synchronization of stars with convective envelopes, and this investigation resulted in rotation period measurements for over 800 such stars. At orbital periods below approximately ten days, nearly all binaries are synchronized, while beyond ten days most binaries have eccentric orbits and rotation rates that are synchronized to the angular velocity at periastron. An unexpected result was that 15% of binaries with orbital periods below ten days are rotating about 13% slower than the synchronized rate. It was suggested that the equators of the stars are in fact synchronized, and that the subsynchronous signal originates from slower rotating high latitudes. The subsynchronous population presents a new test for theories of activity and differential rotation in tidally interacting binaries. The final investigation used Pan-STARRS observations to search for asymmetries in the disk of the Milky Way. In this case, low mass stars served as tracers of Galactic structure. Previous deep optical surveys avoided the Galactic plane, but Pan-STARRS enabled a comprehensive search. In particular, asymmetries in the stellar density distribution may be the result of interactions with satellite galaxies, and the frequency and nature of the interactions provide an observational test case for theories of galaxy formation. (Abstract shortened by ProQuest.).

  6. Turbulent flow in rib-roughened channel under the effect of Coriolis and rotational buoyancy forces

    NASA Astrophysics Data System (ADS)

    Coletti, Filippo; Jacono, David Lo; Cresci, Irene; Arts, Tony

    2014-04-01

    The turbulent flow inside a rotating channel provided with transverse ribs along one wall is studied by means of two-dimensional time-resolved particle image velocimetry. The measurement set-up is mounted on the same rotating disk with the test section, allowing to obtain the same accuracy and resolution as in a non-rotating rig. The Reynolds number is 15 000, and the rotation number is 0.38. As the ribbed wall is heated, both the Coriolis force and the centrifugal force play a role in the fluid dynamics. The mean velocity fields highlight the major impact of the rotational buoyancy (characterized by a buoyancy number of 0.31) on the flow along the leading side of the duct. In particular, since the flow is directed radially outward, the near-wall layers experience significant centripetal buoyancy. The recirculation area behind the obstacles is enlarged to the point of spanning the whole inter-rib space. Also the turbulent fluctuations are significantly altered, and overall augmented, with respect to the non-buoyant case, resulting in higher turbulence levels far from the rib. On the other hand the centrifugal force has little or no impact on the flow along the trailing wall. Vortex identification, proper orthogonal decomposition, and two-point correlations are used to highlight rotational effects, and in particular to determine the dominant scales of the turbulent unsteady flow, the time-dependent behavior of the shear layer and of the recirculation bubble behind the wall-mounted obstacles, the lifetime and advection velocity of the coherent structures.

  7. Heat transfer in a rotating cavity with a stationary stepped casing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mirzaee, I.; Quinn, P.; Wilson, M.

    1999-04-01

    In the system considered here, corotating turbine disks are cooled by air supplied at the periphery of the system. The system comprises two corotating disks, connected by a rotating cylindrical hub and shrouded by a stepped, stationary cylindrical outer casing. Cooling air enters the system through holes in the periphery of one disk, and leaves through the clearances between the outer casing and the disks. The paper describes a combined computational and experimental study of the heat transfer in the above-described system. In the experiments, one rotating disk is heated, the hub and outer casing are insulated, and the othermore » disk is quasi-adiabatic. Thermocouples and fluxmeters attached to the heated disc enable the Nusselt numbers, Nu, to be determined for a wide range of rotational speeds and coolant flow rates. Computations are carried out using an axisymmetric elliptic solver incorporating the Launder-Sharma low-Reynolds-number {kappa}-{epsilon} turbulence model. The flow structure is shown to be complex and depends strongly on the so-called turbulent flow parameter, {lambda}{sub T}, which incorporates both rotational speed and flow rate. For a given value of {lambda}{sub T}, the computations show that Nu increases as Re{sub {phi}}, the rotational Reynolds number, increases. Despite the complexity of the flow, the agreement between the computed and measured Nusselt numbers is reasonably good.« less

  8. Test Results for Rotordynamic Coefficients of the SSME HPOTP Turbine Interstage Seal with Two Swirl Brakes

    NASA Technical Reports Server (NTRS)

    Childs, Dara W.; Baskharone, Erian; Ramsey, Christopher

    1991-01-01

    Test results are presented for the HPOTP Turbine Interstage Seal with both the current and an alternate, aerodynamically designed, swirl brake. Tests were conducted at speeds out to 16,000 rpm, supply pressures up to 18.3 bars, and the following three inlet tangential velocity conditions: (1) no preswirl; (2) intermediate preswirl in the direction of rotation; and (3) high preswirl in the direction of rotation. The back pressure can be controlled independently and was varied to yield the following four pressure ratios: 0.4, 0.45, 0.56, and 0.67. The central and simplest conclusion to be obtained from the test series is that the alternate swirl brake consistently outperforms the current swirl brake in terms of stability performance. The alternate swirl brake's whirl frequency ratio was generally about one half or less than corresponding values for the current design. In many cases, the alternate design yielded negative whirl frequency ratio values in comparison to positive values for the current design. The alternate design can be directly substituted into the space currently occupied by the current design. There is no change in leakage performance.

  9. Plasma-based Compressor Stall Control

    NASA Astrophysics Data System (ADS)

    McGowan, Ryan; Corke, Thomas

    2017-11-01

    The use of dielectric barrier discharge (DBD) plasma actuator casing treatment to prevent or delay stall inception in an axial fan is examined. The actuators are powered by a pulsed-DC waveform which induces a larger peak velocity than a purely AC waveform such as a sine or sawtooth wave. With this system, a high-voltage DC source is supplied to both electrodes, remaining constant in time for the exposed electrode. Meanwhile, the covered electrode is periodically grounded for several microseconds and allowed to rise back to the source DC level. To test the actuators' ability to interact with and modify the formation of stall cells, a facility has been designed and constructed around nonconductive fan blades. The actuators are installed in the fan casing near the blade tips. The instrumentation allows for the measurement of rotating pressure disturbances (traveling stall cells) in this tip gap region as well as fan performance characteristics including pressure rise and flow rate. The casing plasma actuation is found to reduce the correlation of the rotating stall cells, thereby extending the stall margin of the fan. Various azimuthal arrangements of the plasma actuator casing treatment is explored, as well as input voltage levels to the actuator to determine optimum conditions. NASA SBIR Contract NNX14CC12C.

  10. Rotating black holes with non-Abelian hair

    NASA Astrophysics Data System (ADS)

    Kleihaus, Burkhard; Kunz, Jutta; Navarro-Lérida, Francisco

    2016-12-01

    We here review asymptotically flat rotating black holes in the presence of non-Abelian gauge fields. Like their static counterparts these black holes are no longer uniquely determined by their global charges. In the case of pure SU(2) Yang-Mills fields, the rotation generically induces an electric charge, while the black holes do not carry a magnetic charge. When a Higgs field is coupled, rotating black holes with monopole hair arise in the case of a Higgs triplet, while in the presence of a complex Higgs doublet the black holes carry sphaleron hair. The inclusion of a dilaton allows for Smarr type mass formulae.

  11. Zig-zag tape influence in NREL Phase VI wind turbine

    NASA Astrophysics Data System (ADS)

    Gomez-Iradi, Sugoi; Munduate, Xabier

    2014-06-01

    Two bladed 10 metre diameter wind turbine was tested in the 24.4m × 36.6m NASA-Ames wind tunnel (Phase VI). These experiments have been extensively used for validation purposes for CFD and other engineering tools. The free transition case (S), has been, and is, the most employed one for validation purposes, and consist in a 3° pitch case with a rotational speed of 72rpm upwind configuration with and without yaw misalignment. However, there is another less visited case (M) where identical configuration was tested but with the inclusion of a zig-zag tape. This was called transition fixed sequence. This paper shows the differences between the free and the fix transition cases, that should be more appropriate for comparison with fully turbulent simulations. Steady k-ω SST fully turbulent computations performed with WMB CFD method are compared with the experiments showing, better predictions in the attached flow region when it is compared with the transition fixed experiments. This work wants to prove the utility of M case (transition fixed) and show its differences respect the S case (free transition) for validation purposes.

  12. A novel approach for evaluation of prostate deformation and associated dosimetric implications in IGRT of the prostate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayyas, Essa, E-mail: emayyas1@hfhs.org, E-mail: ortonc@comcast.net; Kim, Jinkoo; Kumar, Sanath

    2014-09-15

    Purpose: Prostate deformation is assumed to be a secondary correction and is typically ignored in the planning target volume (PTV) margin calculations. This assumption needs to be tested, especially when planning margins are reduced with daily image-guidance. In this study, deformation characteristics of the prostate and seminal vesicles were determined, and the dosimetric impact on treatment plans with different PTV margins was investigated. Methods: Ten prostate cancer patients were retrospectively selected for the study, each with three fiducial markers implanted in the prostate. Two hundred CBCT images were registered to respective planning CT images using a B-spline-based deformable image registrationmore » (DIR) software. A manual bony anatomy-based match was first applied based on the alignment of the pelvic bones and fiducial landmarks. DIR was then performed. For each registration, deformation vector fields (DVFs) of the prostate and seminal vesicles (SVs) were quantified using deformation-volume histograms. In addition, prostate rotation was evaluated and compared with prostate deformation. For a patient demonstrating small and large prostate deformations, target coverage degradation was analyzed in each of three treatment plans with PTV margins of 10 mm (6 mm at the prostate/rectum interface), as well as 5, and 3 mm uniformly. Results: Deformation of the prostate was most significant in the anterior direction. Maximum prostate deformation of greater than 10, 5, and 3 mm occurred in 1%, 17%, and 76% of the cases, respectively. Based on DVF-histograms, DVF magnitudes greater than 5 and 3 mm occurred in 2% and 27% of the cases, respectively. Deformation of the SVs was most significant in the posterior direction, and it was greater than 5 and 3 mm in 7.5% and 44.9% of the cases, respectively. Prostate deformation was found to be poorly correlated with rotation. Fifty percent of the cases showed rotation with negligible deformation and 7% of the cases showed significant deformation with minimal rotation (<3°). Average differences in the D{sub 95} dose to the prostate + SVs between the planning CT and CBCT images was 0.4% ± 0.5%, 3.0% ± 2.8%, and 6.6% ± 6.1%, respectively, for the plans with 10/6, 5, and 3 mm margins. For the case with both a large degree of prostate deformation (≈10% of the prostate volume) and rotation (≈8°), D{sub 95} was reduced by 0.5% ± 0.1%, 6.8% ± 0.6%, and 20.9% ± 1.6% for 10/6, 5, and 3 mm margin plans, respectively. For the case with large prostate deformation but negligible rotation (<1°), D{sub 95} was reduced by 0.4 ± 0.3, 3.9 ± 1.0, and 11.5 ± 2.5 for 10/6, 5, and 3 mm margin plans, respectively. Conclusions: Prostate deformation over a course of fractionated prostate radiotherapy may not be insignificant and may need to be accounted for in the planning margin design. A consequence of these results is that use of highly reduced planning margins must be viewed with caution.« less

  13. Satellite angular velocity estimation based on star images and optical flow techniques.

    PubMed

    Fasano, Giancarmine; Rufino, Giancarlo; Accardo, Domenico; Grassi, Michele

    2013-09-25

    An optical flow-based technique is proposed to estimate spacecraft angular velocity based on sequences of star-field images. It does not require star identification and can be thus used to also deliver angular rate information when attitude determination is not possible, as during platform de tumbling or slewing. Region-based optical flow calculation is carried out on successive star images preprocessed to remove background. Sensor calibration parameters, Poisson equation, and a least-squares method are then used to estimate the angular velocity vector components in the sensor rotating frame. A theoretical error budget is developed to estimate the expected angular rate accuracy as a function of camera parameters and star distribution in the field of view. The effectiveness of the proposed technique is tested by using star field scenes generated by a hardware-in-the-loop testing facility and acquired by a commercial-off-the shelf camera sensor. Simulated cases comprise rotations at different rates. Experimental results are presented which are consistent with theoretical estimates. In particular, very accurate angular velocity estimates are generated at lower slew rates, while in all cases the achievable accuracy in the estimation of the angular velocity component along boresight is about one order of magnitude worse than the other two components.

  14. Satellite Angular Velocity Estimation Based on Star Images and Optical Flow Techniques

    PubMed Central

    Fasano, Giancarmine; Rufino, Giancarlo; Accardo, Domenico; Grassi, Michele

    2013-01-01

    An optical flow-based technique is proposed to estimate spacecraft angular velocity based on sequences of star-field images. It does not require star identification and can be thus used to also deliver angular rate information when attitude determination is not possible, as during platform de tumbling or slewing. Region-based optical flow calculation is carried out on successive star images preprocessed to remove background. Sensor calibration parameters, Poisson equation, and a least-squares method are then used to estimate the angular velocity vector components in the sensor rotating frame. A theoretical error budget is developed to estimate the expected angular rate accuracy as a function of camera parameters and star distribution in the field of view. The effectiveness of the proposed technique is tested by using star field scenes generated by a hardware-in-the-loop testing facility and acquired by a commercial-off-the shelf camera sensor. Simulated cases comprise rotations at different rates. Experimental results are presented which are consistent with theoretical estimates. In particular, very accurate angular velocity estimates are generated at lower slew rates, while in all cases the achievable accuracy in the estimation of the angular velocity component along boresight is about one order of magnitude worse than the other two components. PMID:24072023

  15. Intersection of reality and fiction in art perception: pictorial space, body sway and mental imagery.

    PubMed

    Ganczarek, Joanna; Ruggieri, V; Nardi, D; Olivetti Belardinelli, M

    2015-09-01

    The thesis of embodied cognition claims that perception of the environment entails a complex set of multisensory processes which forms a basis for the agent's potential and immediate actions. However, in the case of artworks, an agent becomes an observer and action turns into a reaction. This raises questions about the presence of embodied or situated cognition involved in art reception. The study aimed to assess the bodily correlates of perceiving fictional pictorial spaces in the absence of a possibility of an actual physical immersion or manipulation of represented forms. The subjects were presented with paintings by Vermeer and De Hooch, whilst their body sway and eye movements were recorded. Moreover, test and questionnaires on mental imagery (MRT, VVIQ and OSIQ) were administered. Three major results were obtained: (1) the degree of pictorial depth did not influence body sway; (2) fixations to distant elements in paintings (i.e. backgrounds) were accompanied by an increase in body sway; and (3) mental rotation test scores correlated positively with body sway. Our results suggest that in certain cases--despite the fictional character of art--observers' reactions resemble reactions to real stimuli. It is proposed that these reactions are mediated by mental imagery (e.g. mental rotation) that contributes to the act of representing alternative to real artistic spaces.

  16. Keeping It in Three Dimensions: Measuring the Development of Mental Rotation in Children with the Rotated Colour Cube Test (RCCT).

    PubMed

    Lütke, Nikolay; Lange-Küttner, Christiane

    2015-08-03

    This study introduces the new Rotated Colour Cube Test (RCCT) as a measure of object identification and mental rotation using single 3D colour cube images in a matching-to-sample procedure. One hundred 7- to 11-year-old children were tested with aligned or rotated cube models, distracters and targets. While different orientations of distracters made the RCCT more difficult, different colours of distracters had the opposite effect and made the RCCT easier because colour facilitated clearer discrimination between target and distracters. Ten-year-olds performed significantly better than 7- to 8-year-olds. The RCCT significantly correlated with children's performance on the Raven's Coloured Progressive Matrices Test (RCPM) presumably due to the shared multiple-choice format, but the RCCT was easier, as it did not require sequencing. Children from families with a high socio-economic status performed best on both tests, with boys outperforming girls on the more difficult RCCT test sections.

  17. Effects of enhanced stratification on equatorward dynamo wave propagation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Käpylä, Petri J.; Mantere, Maarit J.; Cole, Elizabeth

    We present results from simulations of rotating magnetized turbulent convection in spherical wedge geometry representing parts of the latitudinal and longitudinal extents of a star. Here we consider a set of runs for which the density stratification is varied, keeping the Reynolds and Coriolis numbers at similar values. In the case of weak stratification, we find quasi-steady dynamo solutions for moderate rotation and oscillatory ones with poleward migration of activity belts for more rapid rotation. For stronger stratification, the growth rate tends to become smaller. Furthermore, a transition from quasi-steady to oscillatory dynamos is found as the Coriolis number ismore » increased, but now there is an equatorward migrating branch near the equator. The breakpoint where this happens corresponds to a rotation rate that is about three to seven times the solar value. The phase relation of the magnetic field is such that the toroidal field lags behind the radial field by about π/2, which can be explained by an oscillatory α{sup 2} dynamo caused by the sign change of the α-effect about the equator. We test the domain size dependence of our results for a rapidly rotating run with equatorward migration by varying the longitudinal extent of our wedge. The energy of the axisymmetric mean magnetic field decreases as the domain size increases and we find that an m = 1 mode is excited for a full 2π azimuthal extent, reminiscent of the field configurations deduced from observations of rapidly rotating late-type stars.« less

  18. Alternative Gravity Rotation Curves for the LITTLE THINGS Survey

    NASA Astrophysics Data System (ADS)

    O’Brien, James G.; Chiarelli, Thomas L.; Dentico, Jeremy; Stulge, Modestas; Stefanski, Brian; Moss, Robert; Chaykov, Spasen

    2018-01-01

    Galactic rotation curves have proven to be the testing ground for dark matter bounds in spiral galaxies of all morphologies. Dwarf galaxies serve as an increasingly interesting case of rotation curve dynamics due to their typically rising rotation curve as opposed to the flattening curve of large spirals. Dwarf galaxies usually vary in galactic structure and mostly terminate at small radial distances. This, coupled with the fact that Cold Dark Matter theories struggle with the universality of galactic rotation curves, allow for exclusive features of alternative gravitational models to be analyzed. Recently, The H I Nearby Galactic Survey (THINGS) has been extended to include a sample of 25 dwarf galaxies now known as the LITTLE THINGS Survey. Here, we show an application of alternative gravitational models to the LITTLE THINGS survey, specifically focusing on conformal gravity (CG) and Modified Newtonian Dynamics (MOND). In this work, we provide an analysis and discussion of the rotation curve predictions of each theory to the sample. Furthermore, we show how these two alternative gravitational models account for the recently observed universal trends in centripetal accelerations in spiral galaxies. This work highlights the similarities and differences of the predictions of the two theories in dwarf galaxies. The sample is not large or diverse enough to strongly favor a single theory, but we posit that both CG and MOND can provide an accurate description of the galactic dynamics in the LITTLE THINGS sample without the need for dark matter.

  19. Ultrasound and Functional Assessment of Transtendinous Repairs of Partial-Thickness Articular-Sided Rotator Cuff Tears.

    PubMed

    Ostrander, Roger V; Klauser, Jeffrey M; Menon, Sanjay; Hackel, Joshua G

    2017-03-01

    Partial-thickness articular-sided rotator cuff tears are a frequent source of shoulder pain. Despite conservative measures, some patients continue to be symptomatic and require surgical management. However, there is some controversy as to which surgical approach results in the best outcomes for grade 3 tears. The purpose of this study was to evaluate repair integrity and the clinical results of patients treated with transtendinous repair of high-grade partial-thickness articular-sided rotator cuff tears. Our hypothesis was that transtendinous repairs would result in reliable healing and acceptable functional outcomes. Case series; Level of evidence, 4. Twenty patients with a minimum follow-up of 2 years were included in the study. All patients underwent arthroscopic repair of high-grade partial-thickness rotator cuff tears utilizing a transtendinous technique by a single surgeon. At latest follow-up, the repair integrity was evaluated using ultrasound imaging, and functional scores were calculated. Ultrasound evaluation demonstrated that 18 of 20 patients had complete healing with a normal-appearing rotator cuff. Two patients had a minor residual partial tear. Sixteen of 20 patients had no pain on visual analog scale. Four patients complained of mild intermittent residual pain. All patients were rated as "excellent" by both the University of California at Los Angeles Shoulder Score and the Simple Shoulder Test. The transtendon technique for the repair of articular-sided high-grade partial rotator cuff tears results in reliable tendon healing and excellent functional outcomes.

  20. Reynolds-Stress and Triple-Product Models Applied to Flows with Rotation and Curvature

    NASA Technical Reports Server (NTRS)

    Olsen, Michael E.

    2016-01-01

    Predictions for Reynolds-stress and triple product turbulence models are compared for flows with significant rotational effects. Driver spinning cylinder flowfield and Zaets rotating pipe case are to be investigated at a minimum.

  1. Delayed rotation of the cerebellar vermis: a pitfall in early second-trimester fetal magnetic resonance imaging.

    PubMed

    Pinto, J; Paladini, D; Severino, M; Morana, G; Pais, R; Martinetti, C; Rossi, A

    2016-07-01

    We describe two cases in which delayed rotation of the cerebellar vermis simulated a Dandy-Walker malformation (DWM) on early second-trimester magnetic resonance imaging (MRI). Two pregnant women with suspected fetal posterior fossa anomaly on ultrasound examination underwent fetal MRI at 21 (Case 1) and 19 (Case 2) weeks' gestation. In both cases, upward rotation of the cerebellar vermis was noted; on midsagittal imaging, the brainstem-vermis angle was 28° and 43°, respectively, while cerebellar morphometry showed a reduced vermian anteroposterior diameter compared to reference data. The posterior fossa appeared to be mildly enlarged, while all other findings were normal. Follow-up MRI at 28 + 3 weeks' gestation (Case 1) and at 1 postnatal year (Case 2) showed completely normal findings. Both children had normal psychomotor development and neurological examinations at 1 year of age. Incomplete rotation of the cerebellar vermis can be a physiological finding on early second-trimester fetal MRI examination and can simulate DWM or other forms of cerebellar hypoplasia. Embryologically, delayed permeabilization of Blake's pouch could account for the delayed vermian rotation. Follow-up imaging at a later gestational age is crucial to ensure that this condition is not over-reported and to avoid the potential risk of unnecessary pregnancy interruption. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  2. Comparison of helical scan and standard rotation methods in single-crystal X-ray data collection strategies.

    PubMed

    Polsinelli, Ivan; Savko, Martin; Rouanet-Mehouas, Cecile; Ciccone, Lidia; Nencetti, Susanna; Orlandini, Elisabetta; Stura, Enrico A; Shepard, William

    2017-01-01

    X-ray radiation in macromolecular crystallography can chemically alter the biological material and deteriorate the integrity of the crystal lattice with concomitant loss of resolution. Typical alterations include decarboxylation of glutamic and aspartic residues, breaking of disulfide bonds and the reduction of metal centres. Helical scans add a small translation to the crystal in the rotation method, so that for every image the crystal is shifted to expose a fresh part. On beamline PROXIMA 2A at Synchrotron SOLEIL, this procedure has been tested with various parameters in an attempt to understand how to mitigate the effects of radiation damage. Here, the strategies used and the crystallographic metrics for various scenarios are reported. Among these, the loss of bromine from bromophenyl moieties appears to be a useful monitor of radiation damage as the carbon-bromine bond is very sensitive to X-ray irradiation. Two cases are focused on where helical scans are shown to be superior in obtaining meaningful data compared with conventional methods. In one case the initial resolution of the crystal is extended over time, and in the second case the anomalous signal is preserved to provide greater effective multiplicity and easier phasing.

  3. A weighted adjustment of a similarity transformation between two point sets containing errors

    NASA Astrophysics Data System (ADS)

    Marx, C.

    2017-10-01

    For an adjustment of a similarity transformation, it is often appropriate to consider that both the source and the target coordinates of the transformation are affected by errors. For the least squares adjustment of this problem, a direct solution is possible in the cases of specific-weighing schemas of the coordinates. Such a problem is considered in the present contribution and a direct solution is generally derived for the m-dimensional space. The applied weighing schema allows (fully populated) point-wise weight matrices for the source and target coordinates, both weight matrices have to be proportional to each other. Additionally, the solutions of two borderline cases of this weighting schema are derived, which only consider errors in the source or target coordinates. The investigated solution of the rotation matrix of the adjustment is independent of the scaling between the weight matrices of the source and the target coordinates. The mentioned borderline cases, therefore, have the same solution of the rotation matrix. The direct solution method is successfully tested on an example of a 3D similarity transformation using a comparison with an iterative solution based on the Gauß-Helmert model.

  4. Innominate movement patterns, rotation trends and range of motion in individuals with low back pain of sacroiliac joint origin.

    PubMed

    Adhia, Divya Bharatkumar; Milosavljevic, Stephan; Tumilty, Steve; Bussey, Melanie D

    2016-02-01

    Innominate kinematic anomalies resulting in low back pain (LBP) of sacroiliac joint (SIJ) origin (SIJ-positive), has always been a topic of contention, owing to difficultly in its evaluation. Recent technique of electromagnetic palpation-digitization has been able to accurately quantify innominate kinematics in healthy individuals. The purpose of this study is to determine if participants with LBP of SIJ origin (SIJ-positive) demonstrate significantly different innominate kinematics than participants with LBP of non-SIJ origin (SIJ-negative). Single-blinded cross-sectional case-control study. Participants [n(122)] between the ages of 18 to 50 years, suffering from chronic non-specific LBP (≥3 months) volunteered in the study. An experienced musculoskeletal physiotherapist evaluated and classified participants into either SIJ-positive [n(45)] or SIJ-negative [n(77)] group, using the reference standard pain provocation tests [≥3 positive tests = SIJ-positive]. A research physiotherapist, blinded to clinical groups, conducted the innominate kinematic testing using a valid and reliable electromagnetic palpation-digitization technique, during prone lying incremental hip abduction-external rotation test positions. The results of the mixed model regression analyses demonstrated that SIJ-positive participants exhibited significantly different innominate movement patterns and trends of rotation, but not innominate ranges of motion, when compared with SIJ-negative LBP participants. These findings demonstrate association between SIJ pain and altered innominate kinematics, and have led the groundwork for further exploration of clinical measurement, relevance, and management of these potentially important movement observations. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Clinical investigation of vestibular damage by antituberculous drugs.

    PubMed

    Nakayama, M; Natori, Y; Tachi, H; Yoshizawa, M; Takayama, S; Miura, H; Kanayama, M; Kamei, T

    1986-01-01

    Vestibular function testing was done regularly on the cases given streptomycin, kanamycin, or enviomycin and a method to detect the cases of vestibular dysfunction at an early stage was discussed, as well as the time these drugs should be discontinued. Subjects were 85 cases of tuberculosis treated with streptomycin, kanamycin, or enviomycin who were admitted to our hospital from December 1984 to May 1986. The method of equilibrium examination performed at regular intervals is as follows: standing test (Romberg test), stepping test, and Meyer zum Gottesberge's head-shaking test were done once a week for a month after starting antituberculous injections and they were re-examined once every 2 weeks for at least 3 months after beginning the injections. After the 3 months these tests were done once a month. Eight cases of vestibular damage due to streptomycin or enviomycin could be easily detected at an early stage by performing Meyer zum Gottesberge's head-shaking test, together with the standing test and the stepping test. Vestibular dysfunction is apt to occur after about 1 month or within a month from the start of daily injections especially with streptomycin. Therefore, the method of equilibrium examination, we suggest, is that the Meyer zum Gottesberge's head-shaking test, the standing test (Romberg test), and the stepping test should be performed once a week during the first month after the start of this drug. When the result of the Meyer zum Gottesberge's head-shaking test is less than 50% and swaying and/or rotation occur in the stepping test, the drugs being given should be discontinued.

  6. Improved source inversion from joint measurements of translational and rotational ground motions

    NASA Astrophysics Data System (ADS)

    Donner, S.; Bernauer, M.; Reinwald, M.; Hadziioannou, C.; Igel, H.

    2017-12-01

    Waveform inversion for seismic point (moment tensor) and kinematic sources is a standard procedure. However, especially in the local and regional distances a lack of appropriate velocity models, the sparsity of station networks, or a low signal-to-noise ratio combined with more complex waveforms hamper the successful retrieval of reliable source solutions. We assess the potential of rotational ground motion recordings to increase the resolution power and reduce non-uniquenesses for point and kinematic source solutions. Based on synthetic waveform data, we perform a Bayesian (i.e. probabilistic) inversion. Thus, we avoid the subjective selection of the most reliable solution according the lowest misfit or other constructed criterion. In addition, we obtain unbiased measures of resolution and possible trade-offs. Testing different earthquake mechanisms and scenarios, we can show that the resolution of the source solutions can be improved significantly. Especially depth dependent components show significant improvement. Next to synthetic data of station networks, we also tested sparse-network and single station cases.

  7. Holographic Optical Elements as Scanning Lidar Telescopes

    NASA Technical Reports Server (NTRS)

    Schwemmer, Geary K.; Rallison, Richard D.; Wilkerson, Thomas D.; Guerra, David V.

    2005-01-01

    We have developed and investigated the use of holographic optical elements (HOEs) and holographic transmission gratings for scanning lidar telescopes. For example, rotating a flat HOE in its own plane with the focal spot on the rotation axis makes a very simple and compact conical scanning telescope. We developed and tested transmission and reflection HOEs for use at the first three harmonic wavelengths of Nd:YAG lasers. The diffraction efficiency, diffraction angle, focal length, focal spot size and optical losses were measured for several HOEs and holographic gratings, and found to be suitable for use as lidar receiver telescopes, and in many cases could also serve as the final collimating and beam steering optic for the laser transmitter. Two lidar systems based on this technology have been designed, built, and successfully tested in atmospheric science applications. This technology will enable future spaceborne lidar missions by significantly lowering the size, weight, power requirement and cost of a large aperture, narrow field of view scanning telescope.

  8. Extracting black-hole rotational energy: The generalized Penrose process

    NASA Astrophysics Data System (ADS)

    Lasota, J.-P.; Gourgoulhon, E.; Abramowicz, M.; Tchekhovskoy, A.; Narayan, R.

    2014-01-01

    In the case involving particles, the necessary and sufficient condition for the Penrose process to extract energy from a rotating black hole is absorption of particles with negative energies and angular momenta. No torque at the black-hole horizon occurs. In this article we consider the case of arbitrary fields or matter described by an unspecified, general energy-momentum tensor Tμν and show that the necessary and sufficient condition for extraction of a black hole's rotational energy is analogous to that in the mechanical Penrose process: absorption of negative energy and negative angular momentum. We also show that a necessary condition for the Penrose process to occur is for the Noether current (the conserved energy-momentum density vector) to be spacelike or past directed (timelike or null) on some part of the horizon. In the particle case, our general criterion for the occurrence of a Penrose process reproduces the standard result. In the case of relativistic jet-producing "magnetically arrested disks," we show that the negative energy and angular-momentum absorption condition is obeyed when the Blandford-Znajek mechanism is at work, and hence the high energy extraction efficiency up to ˜300% found in recent numerical simulations of such accretion flows results from tapping the black hole's rotational energy through the Penrose process. We show how black-hole rotational energy extraction works in this case by describing the Penrose process in terms of the Noether current.

  9. General principles in motion vision: color blindness of object motion depends on pattern velocity in honeybee and goldfish.

    PubMed

    Stojcev, Maja; Radtke, Nils; D'Amaro, Daniele; Dyer, Adrian G; Neumeyer, Christa

    2011-07-01

    Visual systems can undergo striking adaptations to specific visual environments during evolution, but they can also be very "conservative." This seems to be the case in motion vision, which is surprisingly similar in species as distant as honeybee and goldfish. In both visual systems, motion vision measured with the optomotor response is color blind and mediated by one photoreceptor type only. Here, we ask whether this is also the case if the moving stimulus is restricted to a small part of the visual field, and test what influence velocity may have on chromatic motion perception. Honeybees were trained to discriminate between clockwise- and counterclockwise-rotating sector disks. Six types of disk stimuli differing in green receptor contrast were tested using three different rotational velocities. When green receptor contrast was at a minimum, bees were able to discriminate rotation directions with all colored disks at slow velocities of 6 and 12 Hz contrast frequency but not with a relatively high velocity of 24 Hz. In the goldfish experiment, the animals were trained to detect a moving red or blue disk presented in a green surround. Discrimination ability between this stimulus and a homogenous green background was poor when the M-cone type was not or only slightly modulated considering high stimulus velocity (7 cm/s). However, discrimination was improved with slower stimulus velocities (4 and 2 cm/s). These behavioral results indicate that there is potentially an object motion system in both honeybee and goldfish, which is able to incorporate color information at relatively low velocities but is color blind with higher speed. We thus propose that both honeybees and goldfish have multiple subsystems of object motion, which include achromatic as well as chromatic processing.

  10. Spiral galaxy HI models, rotation curves and kinematic classifications

    NASA Astrophysics Data System (ADS)

    Wiegert, Theresa B. V.

    Although galaxy interactions cause dramatic changes, galaxies also continue to form stars and evolve when they are isolated. The dark matter (DM) halo may influence this evolution since it generates the rotational behaviour of galactic disks which could affect local conditions in the gas. Therefore we study neutral hydrogen kinematics of non-interacting, nearby spiral galaxies, characterising their rotation curves (RC) which probe the DM halo; delineating kinematic classes of galaxies; and investigating relations between these classes and galaxy properties such as disk size and star formation rate (SFR). To generate the RCs, we use GalAPAGOS (by J. Fiege). My role was to test and help drive the development of this software, which employs a powerful genetic algorithm, constraining 23 parameters while using the full 3D data cube as input. The RC is here simply described by a tanh-based function which adequately traces the global RC behaviour. Extensive testing on artificial galaxies show that the kinematic properties of galaxies with inclination >40 degrees, including edge-on galaxies, are found reliably. Using a hierarchical clustering algorithm on parametrised RCs from 79 galaxies culled from literature generates a preliminary scheme consisting of five classes. These are based on three parameters: maximum rotational velocity, turnover radius and outer slope of the RC. To assess the relationship between DM content and the kinematic classes, we generate mass models for 10 galaxies from the THINGS and WHISP surveys, and J. Irwin's sample. In most cases mass models using GalAPAGOS RCs were similar to those using traditional "tilted-ring'' method RCs. The kinematic classes are mainly distinguished by their rotational velocity. We confirm correlations between increasing velocity and B-magnitude, optical disk size, and find earlier type galaxies among the strong rotators. SFR also increases with maximum rotational velocity. Given our limited subsample, we cannot discern a trend of velocity with DM halo properties such as Mhalo/Mbaryon. Using this strategy on upcoming large databases should reveal relationships between the DM halo and our kinematic classification scheme. If NGC 2841, NGC 3521 and NGC 5055 are understood to have declining RC after further investigation, this cannot be explained by the usual morphology scenarios.

  11. Reliability and Concurrent Validity of Dynamic Rotator Stability Test-A Cross Sectional study.

    PubMed

    Binoy Mathew, K V; Eapen, Charu; Kumar, P Senthil

    2012-01-01

    To find intra rater and inter rater reliability of Dynamic Rotator Stability Test (DRST) and to find concurrent validity of Dynamic Rotator Stability Test (DRST) with University of Pennsylvania Shoulder Score (PENN) Scale. 40 subjects of either gender between the age group of 18-70 with painful shoulder conditions of musculoskeletal origin was selected through convenient sampling. Tester 1 and tester 2 administered DRST and PENN scale randomly. In a subgroup of 20 subjects DRST was administered by both the testers to find the inter rater reliability. 180° Standard Universal Goniometer was used to take measurements. For intra-rater reliability, all the test variables were showing highly significant correlation (p=.94 - 1). For inter -rater, with tester 2, test variables like position, ROM, force, direction of abnormal translation, pain during the test, compensatory movement during test were found to be significant (p=.71-1).only some variables of DRST showed significant correlation with PENN scale (P=.320-.450). Dynamic Rotator Stability Test has good intra rater and moderate inter rater reliability. Concurrent validity of Dynamic Rotator Stability Test was found to be poor when compared to PENN Shoulder Score.

  12. Design and testing of a rotational brake with shear thickening fluids

    NASA Astrophysics Data System (ADS)

    Tian, Tongfei; Nakano, Masami

    2017-03-01

    A rotational brake working with shear thickening fluid (STF) was designed and tested in this study. With the optimisation in design, most of the STF in the brake can receive the same shear rate when the brake rotates. The parts of this brake were fabricated with a 3D printer and then assembled manually. Three types of STFs with various carrier fluids and different particles were fabricated and tested with a rheometer. Then the brake with each STF was separately tested with the rheometer. The estimated and measured torques as a function of the angular velocity fit each other well. The stability of the rotational STF brake was investigated in repeated tests, which proved the function of the brake for a long time.

  13. Six-degree-of-freedom local seismic records from micro-earthquakes and anthropogenic events

    NASA Astrophysics Data System (ADS)

    Brokešová, J.; Málek, J.

    2012-04-01

    Full ground motion description, including both translational and rotational components, attracts still more attention in modern seismology. There is a need for portable rotational sensors, easily installed and operated in the field, sensitive enough to provide 6DOF records in a wide range of amplitudes excited not only by strong but also weak motion events. A new prototype of our rotational seismic sensor system (Rotaphone) designed to measure three rotation rate and three ground velocity components is presented. Our method is based on measurements of the differential motions between paired low-frequency geophones attached to a rigid skeleton, the size of which is much smaller than the wavelength of interest. This approach is conditioned by a precise calibration of each paired geophone in the system. A method of our in-situ calibration is explained and demonstrated. The device was thoroughly tested at the Albuquerque Seismological Laboratory, U.S. Geological Survey, with focus on linearity and cross-axis errors. Results of these tests confirm its proper function. The Rotaphone operates in the frequency range 2-40 Hz and its dynamic range is at least 120 dB. It was successfully applied to measure 6DOF ground motions from local shallow micro-earthquakes in the West Bohemia swarm area (Czech Republic), at Hronov-Pozíčí fault zone in East Bohemia (Czech Republic), and in the vicinity of the salt-works of Provadia (Bulgaria). It was also used to obtain records from anthropogenic sources (blasts, rockbursts). Three-axial rotation rate records for these types of events are shown and discussed. Their peak amplitudes reach values from 10-7 rad/s to 10-4 rad/s. To characterize the significance of rotation we define the rotation to translation ratio (RTR) relating peak amplitudes of rotation rate and translational velocity. The RTR factor for different types of local events is discussed in view of its dependence on hypocentral distance, source type and probably on radiation pattern and geological structure along the wavepaths. Thanks to our method of retrieving rotation rates, their records are not contaminated by translational motions. Opposite is not true. Special attention is devoted to the problem of contamination of translational records by rotations. Our approach enables to compensate for this contamination. This procedure is especially important for horizontal translational components that contain a non-negligible contribution from gravity in the case of tilting of the instrument. Possible application of Rotaphones in local seismic networks and seismic prospecting is discussed.

  14. A seal test facility for the measurement of isotropic and anisotropic linear rotordynamic characteristics

    NASA Technical Reports Server (NTRS)

    Adams, M. L.; Yang, T.; Pace, S. E.

    1989-01-01

    A new seal test facility for measuring high-pressure seal rotor-dynamic characteristics has recently been made operational at Case Western Reserve University (CWRU). This work is being sponsored by the Electric Power Research Institute (EPRI). The fundamental concept embodied in this test apparatus is a double-spool-shaft spindle which permits independent control over the spin speed and the frequency of an adjustable circular vibration orbit for both forward and backward whirl. Also, the static eccentricity between the rotating and non-rotating test seal parts is easily adjustable to desired values. By accurately measuring both dynamic radial displacement and dynamic radial force signals, over a wide range of circular orbit frequency, one is able to solve for the full linear-anisotropic model's 12 coefficients rather than the 6 coefficients of the more restrictive isotropic linear model. Of course, one may also impose the isotropic assumption in reducing test data, thereby providing a valid qualification of which seal configurations are well represented by the isotropic model and which are not. In fact, as argued in reference (1), the requirement for maintaining a symmetric total system mass matrix means that the resulting isotropic model needs 5 coefficients and the anisotropic model needs 11 coefficients.

  15. High-fidelity simulation versus case-based discussion for teaching medical students in Brazil about pediatric emergencies.

    PubMed

    Couto, Thomaz Bittencourt; Farhat, Sylvia C L; Geis, Gary L; Olsen, Orjan; Schvartsman, Claudio

    2015-06-01

    To compare high-fidelity simulation with case-based discussion for teaching medical students about pediatric emergencies, as assessed by a knowledge post-test, a knowledge retention test and a survey of satisfaction with the method. This was a non-randomized controlled study using a crossover design for the methods, as well as multiple-choice questionnaire tests and a satisfaction survey. Final-year medical students were allocated into two groups: group 1 participated in an anaphylaxis simulation and a discussion of a supraventricular tachycardia case, and conversely, group 2 participated in a discussion of an anaphylaxis case and a supraventricular tachycardia simulation. Students were tested on each theme at the end of their rotation (post-test) and 4-6 months later (retention test). Most students (108, or 66.3%) completed all of the tests. The mean scores for simulation versus case-based discussion were respectively 43.6% versus 46.6% for the anaphylaxis pre-test (p=0.42), 63.5% versus 67.8% for the post-test (p=0.13) and 61.5% versus 65.5% for the retention test (p=0.19). Additionally, the mean scores were respectively 33.9% versus 31.6% for the supraventricular tachycardia pre-test (p=0.44), 42.5% versus 47.7% for the post-test (p=0.09) and 41.5% versus 39.5% for the retention test (p=0.47). For both themes, there was improvement between the pre-test and the post-test (p<0.05), and no significant difference was observed between the post-test and the retention test (p>0.05). Moreover, the satisfaction survey revealed a preference for simulation (p<0.001). As a single intervention, simulation is not significantly different from case-based discussion in terms of acquisition and retention of knowledge but is superior in terms of student satisfaction.

  16. High-fidelity simulation versus case-based discussion for teaching medical students in Brazil about pediatric emergencies

    PubMed Central

    Couto, Thomaz Bittencourt; Farhat, Sylvia C.L.; Geis, Gary L; Olsen, Orjan; Schvartsman, Claudio

    2015-01-01

    OBJECTIVE: To compare high-fidelity simulation with case-based discussion for teaching medical students about pediatric emergencies, as assessed by a knowledge post-test, a knowledge retention test and a survey of satisfaction with the method. METHODS: This was a non-randomized controlled study using a crossover design for the methods, as well as multiple-choice questionnaire tests and a satisfaction survey. Final-year medical students were allocated into two groups: group 1 participated in an anaphylaxis simulation and a discussion of a supraventricular tachycardia case, and conversely, group 2 participated in a discussion of an anaphylaxis case and a supraventricular tachycardia simulation. Students were tested on each theme at the end of their rotation (post-test) and 4–6 months later (retention test). RESULTS: Most students (108, or 66.3%) completed all of the tests. The mean scores for simulation versus case-based discussion were respectively 43.6% versus 46.6% for the anaphylaxis pre-test (p=0.42), 63.5% versus 67.8% for the post-test (p=0.13) and 61.5% versus 65.5% for the retention test (p=0.19). Additionally, the mean scores were respectively 33.9% versus 31.6% for the supraventricular tachycardia pre-test (p=0.44), 42.5% versus 47.7% for the post-test (p=0.09) and 41.5% versus 39.5% for the retention test (p=0.47). For both themes, there was improvement between the pre-test and the post-test (p<0.05), and no significant difference was observed between the post-test and the retention test (p>0.05). Moreover, the satisfaction survey revealed a preference for simulation (p<0.001). CONCLUSION: As a single intervention, simulation is not significantly different from case-based discussion in terms of acquisition and retention of knowledge but is superior in terms of student satisfaction. PMID:26106956

  17. A non-contacting approach for full field dynamic strain monitoring of rotating structures using the photogrammetry, finite element, and modal expansion techniques

    NASA Astrophysics Data System (ADS)

    Baqersad, Javad

    Health monitoring of rotating structures such as wind turbines and helicopter rotors is generally performed using conventional sensors that provide a limited set of data at discrete locations near or on the hub. These sensors usually provide no data on the blades or interior locations where failures may occur. Within this work, an unique expansion algorithm was extended and combined with finite element (FE) modeling and an optical measurement technique to identify the dynamic strain in rotating structures. The merit of the approach is shown by using the approach to predict the dynamic strain on a small non-rotating and rotating wind turbine. A three-bladed wind turbine having 2.3-meter long blades was placed in a semi-built-in boundary condition using a hub, a machining chuck, and a steel block. A finite element model of the three wind turbine blades assembled to the hub was created and used to extract resonant frequencies and mode shapes. The FE model was validated and updated using experimental modal tests. For the non-rotating optical test, the turbine was excited using a sinusoidal excitation, a pluck test, arbitrary impacts on three blades, and random force excitations with a mechanical shaker. The response of the structure to the excitations was measured using three-dimensional point tracking. A pair of high-speed cameras was used to measure the displacement of optical targets on the structure when the blades were vibrating. The measured displacements at discrete locations were expanded and applied to the finite element model of the structure to extract the full-field dynamic strain. The results of the work show an excellent correlation between the strain predicted using the proposed approach and the strain measured with strain-gages for all of the three loading conditions. Similar to the non-rotating case, optical measurements were also preformed on a rotating wind turbine. The point tracking technique measured both rigid body displacement and flexible deformation of the blades at target locations. The measured displacements were expanded and applied to the finite element model of the turbine to extract full-field dynamic strain on the structure. In order to validate the results for the rotating turbine, the predicted strain was compared to strain measured at four locations on the spinning blades using a wireless strain-gage system. The approach used in this work to predict the strain showed higher accuracy than measurements obtainable by using the digital image correlation technique. The new expansion approach is able to extract dynamic strain all over the entire structure, even inside the structure beyond the line of sight of the measurement system. Because the method is based on a non-contacting measurement approach, it can be readily applied to a variety of structures having different boundary and operating conditions, including rotating blades.

  18. Investigation of Rotating Stall Phenomena in Axial Flow Compressors. Volume I. Basic Studies of Rotating Stall

    DTIC Science & Technology

    1976-06-01

    rotating stall control system which was tested both on a low speed rig and a J-85-S engine. The second objective was to perform fundamental studies of the...Stator Stage 89 6 Annular Cascade Configuration Used for Rotating Stall Studies on Rotoi-Stator Stage ..... .............. ... 90 7 Static Pressure Rise...ground tests on a J-8S-S turbojet engine. The work i3 reported in three separate volumes. Volume I entitled, "Basic Studies of Rotating Stall", covers

  19. Search for subgrid scale parameterization by projection pursuit regression

    NASA Technical Reports Server (NTRS)

    Meneveau, C.; Lund, T. S.; Moin, Parviz

    1992-01-01

    The dependence of subgrid-scale stresses on variables of the resolved field is studied using direct numerical simulations of isotropic turbulence, homogeneous shear flow, and channel flow. The projection pursuit algorithm, a promising new regression tool for high-dimensional data, is used to systematically search through a large collection of resolved variables, such as components of the strain rate, vorticity, velocity gradients at neighboring grid points, etc. For the case of isotropic turbulence, the search algorithm recovers the linear dependence on the rate of strain (which is necessary to transfer energy to subgrid scales) but is unable to determine any other more complex relationship. For shear flows, however, new systematic relations beyond eddy viscosity are found. For the homogeneous shear flow, the results suggest that products of the mean rotation rate tensor with both the fluctuating strain rate and fluctuating rotation rate tensors are important quantities in parameterizing the subgrid-scale stresses. A model incorporating these terms is proposed. When evaluated with direct numerical simulation data, this model significantly increases the correlation between the modeled and exact stresses, as compared with the Smagorinsky model. In the case of channel flow, the stresses are found to correlate with products of the fluctuating strain and rotation rate tensors. The mean rates of rotation or strain do not appear to be important in this case, and the model determined for homogeneous shear flow does not perform well when tested with channel flow data. Many questions remain about the physical mechanisms underlying these findings, about possible Reynolds number dependence, and, given the low level of correlations, about their impact on modeling. Nevertheless, demonstration of the existence of causal relations between sgs stresses and large-scale characteristics of turbulent shear flows, in addition to those necessary for energy transfer, provides important insight into the relation between scales in turbulent flows.

  20. Influence of fluid temperature gradient on the flow within the shaft gap of a PLR pump

    NASA Astrophysics Data System (ADS)

    Qian, W.; Rosic, B.; Zhang, Q.; Khanal, B.

    2016-03-01

    In nuclear power plants the primary-loop recirculation (PLR) pump circulates the high temperature/high-pressure coolant in order to remove the thermal energy generated within the reactor. The pump is sealed using the cold purge flow in the shaft seal gap between the rotating shaft and stationary casing, where different forms of Taylor-Couette flow instabilities develop. Due to the temperature difference between the hot recirculating water and the cold purge water (of order of 200 °C), the flow instabilities in the gap cause temperature fluctuations, which can lead to shaft or casing thermal fatigue cracks. The present work numerically investigated the influence of temperature difference and rotating speed on the structure and dynamics of the Taylor-Couette flow instabilities. The CFD solver used in this study was extensively validated against the experimental data published in the open literature. Influence of temperature difference on the fluid dynamics of Taylor vortices was investigated in this study. With large temperature difference, the structure of the Taylor vortices is greatly stretched at the interface region between the annulus gap and the lower recirculating cavity. Higher temperature difference and rotating speed induce lower fluctuating frequency and smaller circumferential wave number of Taylor vortices. However, the azimuthal wave speed remains unchanged with all the cases tested. The predicted axial location of the maximum temperature fluctuation on the shaft is in a good agreement with the experimental data, identifying the region potentially affected by the thermal fatigue. The physical understandings of such flow instabilities presented in this paper would be useful for future PLR pump design optimization.

  1. Stability of binaries. Part 1: Rigid binaries

    NASA Astrophysics Data System (ADS)

    Sharma, Ishan

    2015-09-01

    We consider the stability of binary asteroids whose members are possibly granular aggregates held together by self-gravity alone. A binary is said to be stable whenever each member is orbitally and structurally stable to both orbital and structural perturbations. To this end, we extend the stability test for rotating granular aggregates introduced by Sharma (Sharma, I. [2012]. J. Fluid Mech., 708, 71-99; Sharma, I. [2013]. Icarus, 223, 367-382; Sharma, I. [2014]. Icarus, 229, 278-294) to the case of binary systems comprised of rubble members. In part I, we specialize to the case of a binary with rigid members subjected to full three-dimensional perturbations. Finally, we employ the stability test to critically appraise shape models of four suspected binary systems, viz., 216 Kleopatra, 25143 Itokawa, 624 Hektor and 90 Antiope.

  2. Clinical rotation in pathology: description of a case based approach.

    PubMed

    Bezuidenhout, J; Wasserman, E; Mansvelt, E; Meyer, C; van Zyl, G; Orth, H; Els, A

    2006-04-01

    The implementation of a system based, integrated curriculum at the Faculty of Health Sciences of Stellenbosch University, Western Cape, South Africa, resulted in less contact time for the pathology disciplines during theoretical modules, while a weekly rotation in pathology was introduced during clinical training in the fourth and fifth years. To describe a problem based approach for this rotation. Students are presented with a clinical "paper" case daily, integrating as many of the pathology disciplines as possible to demonstrate the interdependence of the various disciplines. They receive chemical pathology tutorials, visit the various laboratories, and receive practical training in fine needle aspiration biopsy. On the final day, the case studies are assessed and discussed. Most students appreciated all activities. This rotation enhanced student interactivity and autonomy and guaranteed immediate feedback. On evaluation of the rotation it was found that the students enjoyed the rotation, learnt something new, and realised the value of group work. This innovation integrates pathology with clinical practice and illustrates the use of laboratory medicine in the management of common diseases seen in this country. Students appreciate learning practical skills and having to request special investigations under a pathologist's supervision changes their approach to pathology requests. Familiarity with the pathology environment empowers the student to use pathology with greater ease. A bank of case studies that can be expanded to include all medical disciplines will facilitate the application of a problem based approach and enhance communication between the basic science disciplines and the clinical and pathology disciplines.

  3. The Development of Modal Testing Technology for Wind Turbines: A Historical Perspective

    NASA Technical Reports Server (NTRS)

    James, George H., III; Carne, Thomas G.

    2007-01-01

    Wind turbines are very large, flexible structures, with aerodynamic forces on the rotating blades producing periodic forces with frequencies at the harmonics of the rotation frequency. Due to design consideration, these rotational frequencies are comparable to the modal frequencies; thus avoiding resonant conditions is a critical consideration. Consequently, predicting and experimentally validating the modal frequencies of wind turbines has been important to their successful design and operation. Performing modal tests on flexible structures over 120 meters tall is a substantial challenge, which has inspired innovative developments in modal test technology. A further trial to the analyst and experimentalist is that the modal frequencies are dependent on the turbine rotation speed, so testing a parked turbine does not fully validate the analytical predictions. The history and development of this modal testing technology will be reviewed, showing historical tests and techniques, ranging from two-meter to 100-meter turbines for both parked and rotating tests. The NExT (Natural Excitation Technique) was developed in the 1990's, as a predecessor to OMA to overcome these challenges. We will trace the difficulties and successes of wind turbine modal testing over the past twenty-five years from 1982 to the present.

  4. Foam on Tile Impact Modeling for the Space Shuttle Program

    NASA Technical Reports Server (NTRS)

    Stellingwerf, R. F.; Robinson, J. H.; Richardson, S.; Evans, S. W.; Stallworth, R.; Hovater, M.

    2003-01-01

    Following the breakup of the Space Shuttle Columbia during reentry a NASA-wide investigation team was formed to examine the probable damage inflicted on Orbiter Thermal Protection System (TPS) elements by impact of External Tank insulating foam projectiles. Our team was to apply rigorous, physics-based analysis techniques to help determine parameters of interest for an experimental test program, utilize validated codes to investigate the full range of impact scenarios, and use analysis derived models to predict aero-thermal-structural responses to entry conditions. We were to operate on a non-interference basis with the j Team, and were to supply significant findings to that team and to the Orbiter Vehicle Engineering Working Group, being responsive to any solicitations for support from these entities. The authors formed a working sub-group within the larger team to apply the Smooth Particle Hydrodynamics code SPHC to the damage estimation problem. Numerical models of the LI-900 TPS tiles and of the BX-250 foam were constructed and used as inputs into the code. Material properties needed to properly model the tiles and foam were obtained from other working sub-groups who performed tests on these items for this purpose. Two- and three- dimensional models of the tiles were constructed, including the glass outer layer, the densified lower layer of LI-900 insulation, the Nomex felt Strain Isolation Pad (SIP) mounting layer, and the underlying aluminum 2024 vehicle skin. A model for the BX-250 foam including porous compression, elastic rebound, and surface erosion was developed. Code results for the tile damage and foam behavior were extensively validated through comparison with the Southwest Research Institute (SwRI) foam-on-tile impact experiments carried out in 1999. These tests involved small projectiles striking individual tiles and small tile arrays. Following code and model validation we simulated impacts of larger ET foam projectiles on the TPS tile systems used on the wings of the orbiter. Tiles used on the Wing Acreage, the Main Landing Gear Door, and the Carrier Panels near the front edge of the wing were modeled. Foam impacts shot for the CAB investigation were modeled, as well as impacts at larger angles, including rapid rotation of the projectile, and with varying foam properties. General results suggest that foam impacts on tiles at about 500 mph could cause appreciable damage if the impact angle is greater than about 20 degrees. Some variations of the foam properties, such as increased brittleness or increased density could increase damage in some cases. Rapid (17 rps) rotation failed to increase the damage for the two cases considered. This does not rule out other cases in which the rotational energy might lead to an increase in tile damage, but suggests that in most cases rotation will not be an important factor. Similar models will be applied for other impacting materials, other velocities, and other geometries as part of the Return to Flight process.

  5. Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roper, Justin, E-mail: justin.roper@emory.edu; Department of Biostatistics and Bioinformatics, Winship Cancer Institute of Emory University, Atlanta, Georgia; Chanyavanich, Vorakarn

    2015-11-01

    Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was relatedmore » to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values <95%. Coverage worsened substantially when the rotational error increased to 2.0°: D95 and V95 values were >95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.« less

  6. Analysis of Hydrodynamic Stability of Solar Tachocline Latitudinal Differential Rotation using a Shallow-Water Model

    NASA Astrophysics Data System (ADS)

    Dikpati, Mausumi; Gilman, Peter A.

    2001-04-01

    We examine the global, hydrodynamic stability of solar latitudinal differential rotation in a ``shallow-water'' model of the tachocline. Charbonneau, Dikpati, & Gilman have recently shown that two-dimensional disturbances are stable in the tachocline (which contains a pole-to-equator differential rotation s<18%). In our model, the upper boundary of the thin shell is allowed to deform in latitude, longitude, and time, thus including simplified three-dimensional effects. We examine the stability of differential rotation as a function of the effective gravity of the stratification in the tachocline. High effective gravity corresponds to the radiative part of the tachocline; for this case, the instability is similar to the strictly two-dimensional case (appearing only for s>=18%), driven primarily by the kinetic energy of differential rotation extracted through the work of the Reynolds stress. For low effective gravity, which corresponds to the overshoot part of the tachocline, a second mode of instability occurs, fed again by the kinetic energy of differential rotation, which is primarily extracted by additional stresses and correlations of perturbations arising in the deformed shell. In this case, instability occurs for differential rotation as low as about 11% between equator and pole. If this mode occurs in the Sun, it should destabilize the latitudinal differential rotation in the overshoot part of the tachocline, even without a toroidal field. For the full range of effective gravity, the vorticity associated with the perturbations, coupled with radial motion due to horizontal divergence/convergence of the fluid, gives rise to a longitude-averaged, net kinetic helicity pattern, and hence a source of α-effect in the tachocline. Thus there could be a dynamo in the tachocline, driven by this α-effect and the latitudinal and radial gradients of rotation.

  7. Electrohydrodynamic interactions of spherical particles under Quincke rotation

    NASA Astrophysics Data System (ADS)

    Das, Debasish; Saintillan, David

    2012-11-01

    Quincke rotation denotes the spontaneous rotation of dielectric particles immersed in a slightly dielectric liquid when subjected to a high enough DC electric field. It occurs when the charge relaxation time of the particles is greater than that of the fluid medium, causing the particles to become polarized in a direction opposite to that of the electric field and therefore giving rise to an unstable equilibrium position. When slightly perturbed, the particles start to rotate, and if the electric field exceeds a critical value the perturbations do not decay and the particle rotations reach a steady state with a constant angular velocity. We use a combination of numerical simulations and asymptotic theory to study the effect of electrohydrodynamic interactions between particles under Quincke rotation. We study the prototypical case of two equally charged spheres carrying no net charge and interacting with each other both hydrodynamically and electrically. The case of spherical particles free to roll on a horizontal grounded electrode is also described. We show that Quincke rotation results in self-propulsion of the particles in the plane of the electrode, and interactions between a pair of such ``rollers'' are analyzed.

  8. Rotating-disk sorptive extraction: effect of the rotation mode of the extraction device on mass transfer efficiency.

    PubMed

    Jachero, Lourdes; Ahumada, Inés; Richter, Pablo

    2014-05-01

    The extraction device used in rotating-disk sorptive extraction consists of a Teflon disk in which a sorptive phase is fixed on one of its surfaces. Depending on the configuration, the rotation axis of the disk device can be either perpendicular or parallel to its radius, giving rise to two different mass transfer patterns when rotating-disk sorptive extraction is applied in liquid samples. In the perpendicular case (configuration 1), which is the typical configuration, the disk contains an embedded miniature stir bar that allows the disk rotation to be driven using a common laboratory magnetic stirrer. In the parallel case (configuration 2), the disk is driven by a rotary rod connected to an electric stirrer. In this study, triclosan and its degradation product methyl triclosan were used as analyte models to demonstrate the significant effect of the rotation configuration of the disk on the efficiency of analyte mass transfer from water to a sorptive phase of polydimethylsiloxane. Under the same experimental conditions and at a rotation velocity of 1,250 rpm, extraction equilibrium was reached at 80 min when the disk was rotated in configuration 1 and at 30 min when the disk was rotated in configuration 2. The extraction equilibration time decreased to 14 min when the rotation velocity was increased to 2,000 rpm in configuration 2. Because the rotation pattern affects the mass transfer efficiency, each rotation configuration was characterized through the Reynolds number; Re values of 6,875 and 16,361 were achieved with configurations 1 and 2, respectively, at 1,250 rpm.

  9. Validation of the kinetic-turbulent-neoclassical theory for edge intrinsic rotation in DIII-D

    NASA Astrophysics Data System (ADS)

    Ashourvan, Arash; Grierson, B. A.; Battaglia, D. J.; Haskey, S. R.; Stoltzfus-Dueck, T.

    2018-05-01

    In a recent kinetic model of edge main-ion (deuterium) toroidal velocity, intrinsic rotation results from neoclassical orbits in an inhomogeneous turbulent field [T. Stoltzfus-Dueck, Phys. Rev. Lett. 108, 065002 (2012)]. This model predicts a value for the toroidal velocity that is co-current for a typical inboard X-point plasma at the core-edge boundary (ρ ˜ 0.9). Using this model, the velocity prediction is tested on the DIII-D tokamak for a database of L-mode and H-mode plasmas with nominally low neutral beam torque, including both signs of plasma current. Values for the flux-surface-averaged main-ion rotation velocity in the database are obtained from the impurity carbon rotation by analytically calculating the main-ion—impurity neoclassical offset. The deuterium rotation obtained in this manner has been validated by direct main-ion measurements for a limited number of cases. Key theoretical parameters of ion temperature and turbulent scale length are varied across a wide range in an experimental database of discharges. Using a characteristic electron temperature scale length as a proxy for a turbulent scale length, the predicted main-ion rotation velocity has a general agreement with the experimental measurements for neutral beam injection (NBI) powers in the range PNBI < 4 MW. At higher NBI power, the experimental rotation is observed to saturate and even degrade compared to theory. TRANSP-NUBEAM simulations performed for the database show that for discharges with nominally balanced—but high powered—NBI, the net injected torque through the edge can exceed 1 Nm in the counter-current direction. The theory model has been extended to compute the rotation degradation from this counter-current NBI torque by solving a reduced momentum evolution equation for the edge and found the revised velocity prediction to be in agreement with experiment. Using the theory modeled—and now tested—velocity to predict the bulk plasma rotation opens up a path to more confidently projecting the confinement and stability in ITER.

  10. Retrospective study of sonographic findings in bone involvement associated with rotator cuff calcific tendinopathy: preliminary results of a case series*

    PubMed Central

    Nogueira-Barbosa, Marcello H.; Gregio-Junior, Everaldo; Lorenzato, Mario Muller

    2015-01-01

    Objective The present study was aimed at investigating bone involvement secondary to rotator cuff calcific tendonitis at ultrasonography. Materials and Methods Retrospective study of a case series. The authors reviewed shoulder ultrasonography reports of 141 patients diagnosed with rotator cuff calcific tendonitis, collected from the computer-based data records of their institution over a four-year period. Imaging findings were retrospectively and consensually analyzed by two experienced musculoskeletal radiologists looking for bone involvement associated with calcific tendonitis. Only the cases confirmed by computed tomography were considered for descriptive analysis. Results Sonographic findings of calcific tendinopathy with bone involvement were observed in 7/141 (~ 5%) patients (mean age, 50.9 years; age range, 42-58 years; 42% female). Cortical bone erosion adjacent to tendon calcification was the most common finding, observed in 7/7 cases. Signs of intraosseous migration were found in 3/7 cases, and subcortical cysts in 2/7 cases. The findings were confirmed by computed tomography. Calcifications associated with bone abnormalities showed no acoustic shadowing at ultrasonography, favoring the hypothesis of resorption phase of the disease. Conclusion Preliminary results of the present study suggest that ultrasonography can identify bone abnormalities secondary to rotator cuff calcific tendinopathy, particularly the presence of cortical bone erosion. PMID:26811551

  11. Retrospective study of sonographic findings in bone involvement associated with rotator cuff calcific tendinopathy: preliminary results of a case series.

    PubMed

    Nogueira-Barbosa, Marcello H; Gregio-Junior, Everaldo; Lorenzato, Mario Muller

    2015-01-01

    The present study was aimed at investigating bone involvement secondary to rotator cuff calcific tendonitis at ultrasonography. Retrospective study of a case series. The authors reviewed shoulder ultrasonography reports of 141 patients diagnosed with rotator cuff calcific tendonitis, collected from the computer-based data records of their institution over a four-year period. Imaging findings were retrospectively and consensually analyzed by two experienced musculoskeletal radiologists looking for bone involvement associated with calcific tendonitis. Only the cases confirmed by computed tomography were considered for descriptive analysis. Sonographic findings of calcific tendinopathy with bone involvement were observed in 7/141 (~ 5%) patients (mean age, 50.9 years; age range, 42-58 years; 42% female). Cortical bone erosion adjacent to tendon calcification was the most common finding, observed in 7/7 cases. Signs of intraosseous migration were found in 3/7 cases, and subcortical cysts in 2/7 cases. The findings were confirmed by computed tomography. Calcifications associated with bone abnormalities showed no acoustic shadowing at ultrasonography, favoring the hypothesis of resorption phase of the disease. Preliminary results of the present study suggest that ultrasonography can identify bone abnormalities secondary to rotator cuff calcific tendinopathy, particularly the presence of cortical bone erosion.

  12. Rotating Beam Fatigue Testing and Hybrid Ceramic Bearings.

    DTIC Science & Technology

    1994-07-01

    Runout and Fast Fracture ......... 20 FIG.7 Stress-life Plots of Rotating Beam Fatigue Testing ............. 23 FIG.8 Fractograph of Rotating Beam...Chand-Kare Engineering Ceramics, Worcester, MA. Diamond wheels of 600 grits were used with longitudinal grinding applied for the final finishing of...stress in the range of 600-850 MPa. Three test completion modes were encountered, i.e. fast fracture at setup, fatigue fracture and runout (no failure

  13. WFC3/UVIS External CTE Monitor: Single-Chip CTE Measurements

    NASA Astrophysics Data System (ADS)

    Gosmeyer, C. M.; Baggett, S.

    2016-12-01

    We present the first results of single-chip measurements of charge transfer efficiency (CTE) in the UVIS channel of the Hubble Space Telescope Wide Field Camera 3 (HST/WFC3). This test was performed in Cycle 20 in two visits. In the first visit a field in the star cluster NGC 6583 was observed. In a second visit, the telescope returned to the field, but rotated by 180 degrees and with a shift in pointing that allowed the same stars to be imaged, near and far from the amplifiers, on the same chip of the two-chip UVIS field of-view. This dataset enables a measurement of CTE loss on each separate chip. The current CTE monitor measures CTE loss as an average of the two chips because it dithers by a chip-height to obtain observations of the same sources near and far from the amplifiers, instead of the more difficult to-schedule 180-degree rotation. We find that CTE loss is worse on Chip 1 than on Chip 2 across all cases for which we had data: short and long exposures and w! ith and without the pixel-based CTE correction. In the best case, for long exposures with the CTE correction applied, the max difference between the two chip's flux losses is 3%/2048 pixels. This case should apply for most science observations where the background is 12 e-/pixel. In the worst case of low-background short exposures, e.g. those without post-flash, the max difference between the two chips is 17% flux loss/2048 pixels. Uncertainties are <0.01% flux loss/2048 pixels. Because of the two chips' different CTE loss rates, we will consider adding this test as part of the routine yearly monitor and creating a chip-specific CTE correction software.

  14. A Kaluza-Klein subtractor

    NASA Astrophysics Data System (ADS)

    Jana, Sanjib; Krishnan, Chethan

    2014-05-01

    We generalize the results of arXiv:1212.1875 and arXiv:1212.6919 on attraction basins and their boundaries to the case of a specific class of rotating black holes, namely the ergo-free branch of extremal black holes in Kaluza-Klein theory. We find that exact solutions that span the attraction basin can be found even in the rotating case by appealing to certain symmetries of the equations of motion. They are characterized by two asymptotic parameters that generalize those of the non-rotating case, and the boundaries of the basin are spinning versions of the (generalized) subtractor geometry. We also give examples to illustrate that the shape of the attraction basin can drastically change depending on the theory.

  15. Reversal of orbital angular momentum arising from an extreme Doppler shift

    PubMed Central

    Toninelli, Ermes; Horsley, Simon A. R.; Hendry, Euan; Phillips, David B.; Padgett, Miles J.

    2018-01-01

    The linear Doppler shift is familiar as the rise and fall in pitch of a siren as it passes by. Less well known is the rotational Doppler shift, proportional to the rotation rate between source and receiver, multiplied by the angular momentum carried by the beam. In extreme cases the Doppler shift can be larger than the rest-frame frequency and for a red shift, the observed frequency then becomes “negative.” In the linear case, this effect is associated with the time reversal of the received signal, but it can be observed only with supersonic relative motion between the source and receiver. However, the rotational case is different; if the radius of rotation is smaller than the wavelength, then the velocities required to observe negative frequencies are subsonic. Using an acoustic source at ≈100 Hz we create a rotational Doppler shift larger than the laboratory-frame frequency. We observe that once the red-shifted wave passes into the “negative frequency” regime, the angular momentum associated with the sound is reversed in sign compared with that of the laboratory frame. These low-velocity laboratory realizations of extreme Doppler shifts have relevance to superoscillatory fields and offer unique opportunities to probe interactions with rotating bodies and aspects of pseudorelativistic frame translation. PMID:29581257

  16. Absolute Configuration of 3-METHYLCYCLOHEXANONE by Chiral Tag Rotational Spectroscopy and Vibrational Circular Dichroism

    NASA Astrophysics Data System (ADS)

    Evangelisti, Luca; Holdren, Martin S.; Mayer, Kevin J.; Smart, Taylor; West, Channing; Pate, Brooks

    2017-06-01

    The absolute configuration of 3-methylcyclohexanone was established by chiral tag rotational spectroscopy measurements using 3-butyn-2-ol as the tag partner. This molecule was chosen because it is a benchmark measurement for vibrational circular dichroism (VCD). A comparison of the analysis approaches of chiral tag rotational spectroscopy and VCD will be presented. One important issue in chiral analysis by both methods is the conformational flexibility of the molecule being analyzed. The analysis of conformational composition of samples will be illustrated. In this case, the high spectral resolution of molecular rotational spectroscopy and potential for spectral simplification by conformational cooling in the pulsed jet expansion are advantages for chiral tag spectroscopy. The computational chemistry requirements for the two methods will also be discussed. In this case, the need to perform conformer searches for weakly bound complexes and to perform reasonably high level quantum chemistry geometry optimizations on these complexes makes the computational time requirements less favorable for chiral tag rotational spectroscopy. Finally, the issue of reliability of the determination of the absolute configuration will be considered. In this case, rotational spectroscopy offers a "gold standard" analysis method through the determination of the ^{13}C-subsitution structure of the complex between 3-methylcyclohexanone and an enantiopure sample of the 3-butyn-2-ol tag.

  17. Relationships between spatial activities and scores on the mental rotation test as a function of sex.

    PubMed

    Ginn, Sheryl R; Pickens, Stefanie J

    2005-06-01

    Previous results suggested that female college students' scores on the Mental Rotations Test might be related to their prior experience with spatial tasks. For example, women who played video games scored better on the test than their non-game-playing peers, whereas playing video games was not related to men's scores. The present study examined whether participation in different types of spatial activities would be related to women's performance on the Mental Rotations Test. 31 men and 59 women enrolled at a small, private church-affiliated university and majoring in art or music as well as students who participated in intercollegiate athletics completed the Mental Rotations Test. Women's scores on the Mental Rotations Test benefitted from experience with spatial activities; the more types of experience the women had, the better their scores. Thus women who were athletes, musicians, or artists scored better than those women who had no experience with these activities. The opposite results were found for the men. Efforts are currently underway to assess how length of experience and which types of experience are related to scores.

  18. Ordered structures in rotating ultracold Bose gases

    NASA Astrophysics Data System (ADS)

    Barberán, N.; Lewenstein, M.; Osterloh, K.; Dagnino, D.

    2006-06-01

    Two-dimentional systems of trapped samples of few cold bosonic atoms submitted to strong rotation around the perpendicular axis may be realized in optical lattices and microtraps. We investigate theoretically the evolution of ground state structures of such systems as the rotational frequency Ω increases. Various kinds of ordered structures are observed. In some cases, hidden interference patterns exhibit themselves only in the pair correlation function; in some other cases explicit broken-symmetry structures appear that modulate the density. For N<10 atoms, the standard scenario, valid for large sytems is absent, and is only gradually recovered as N increases. On the one hand, the Laughlin state in the strong rotational regime contains ordered structures much more similar to a Wigner molecule than to a fermionic quantum liquid. On the other hand, in the weak rotational regime, the possibility to obtain equilibrium states, whose density reveals an array of vortices, is restricted to the vicinity of some critical values of the rotational frequency Ω .

  19. Development of a Muon Rotating Target for J-PARC/MUSE

    NASA Astrophysics Data System (ADS)

    Makimura, Shunsuke; Kobayashi, Yasuo; Miyake, Yasuhiro; Kawamura, Naritoshi; Strasser, Patrick; Koda, Akihiro; Shimomura, Koichiro; Fujimori, Hiroshi; Nishiyama, Kusuo; Kato, Mineo; Kojima, Kenji; Higemoto, Wataru; Ito, Takashi; Shimizu, Ryou; Kadono, Ryosuke

    At the J-PARC muon science facility (J-PARC/MUSE), a graphite target with a thickness of 20 mm has been used in vacuum to obtain an intense pulsed muon beam from the RCS 3-GeV proton beam [1], [2]. In the current design, the target frame is constructed using copper with a stainless steel tube embedded for water cooling. The energy deposited by the proton beam at 1 MW is evaluated to be 3.3 kW on the graphite target and 600 W on the copper frame by a Monte-Carlo simulation code, PHITS [3]. Graphite materials are known to lose their crystal structure and can be shrunk under intense proton beam irradiation. Consequently, the lifetime of the muon target is essentially determined by the radiation damage in graphite, and is evaluated to be half a year [4]. Hence, we are planning to distribute the radiation damage by rotating a graphite wheel. Although the lifetime of graphite in this case will be more than 10 years, the design of the bearing must be carefully considered. Because the bearing in JPARC/MUSE is utilized in vacuum, under high radiation, and at high temperature, an inorganic and solid lubricant must be applied to the bearing. Simultaneously, the temperature of the bearing must also be decreased to extend the lifetime. In 2009, a mock-up of the Muon Rotating Target, which could heat up and rotate a graphite wheel, was fabricated. Then several tests were started to select the lubricant and to determine the structure of the Muon Rotating Target, the control system and so on. In this report, the present status of the Muon Rotating Target for J-PARC/MUSE, especially the development of a rotation system in vacuum, is described.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirano, Teruyuki; Winn, Joshua N.; Albrecht, Simon

    We present an improved formula for the anomalous radial velocity of the star during planetary transits due to the Rossiter-McLaughlin (RM) effect. The improvement comes from a more realistic description of the stellar absorption line profiles, taking into account stellar rotation, macroturbulence, thermal broadening, pressure broadening, and instrumental broadening. Although the formula is derived for the case in which radial velocities are measured by cross-correlation, we show through numerical simulations that the formula accurately describes the cases where the radial velocities are measured with the iodine absorption-cell technique. The formula relies on prior knowledge of the parameters describing macroturbulence, instrumentalmore » broadening, and other broadening mechanisms, but even 30% errors in those parameters do not significantly change the results in typical circumstances. We show that the new analytic formula agrees with previous ones that had been computed on a case-by-case basis via numerical simulations. Finally, as one application of the new formula, we reassess the impact of the differential rotation on the RM velocity anomaly. We show that differential rotation of a rapidly rotating star may have a significant impact on future RM observations.« less

  1. Bottom boundary layer forced by finite amplitude long and short surface waves motions

    NASA Astrophysics Data System (ADS)

    Elsafty, H.; Lynett, P.

    2018-04-01

    A multiple-scale perturbation approach is implemented to solve the Navier-Stokes equations while including bottom boundary layer effects under a single wave and under two interacting waves. In this approach, fluid velocities and the pressure field are decomposed into two components: a potential component and a rotational component. In this study, the two components are exist throughout the entire water column and each is scaled with appropriate length and time scales. A one-way coupling between the two components is implemented. The potential component is assumed to be known analytically or numerically a prior, and the rotational component is forced by the potential component. Through order of magnitude analysis, it is found that the leading-order coupling between the two components occurs through the vertical convective acceleration. It is shown that this coupling plays an important role in the bottom boundary layer behavior. Its effect on the results is discussed for different wave-forcing conditions: purely harmonic forcing and impurely harmonic forcing. The approach is then applied to derive the governing equations for the bottom boundary layer developed under two interacting wave motions. Both motions-the shorter and the longer wave-are decomposed into two components, potential and rotational, as it is done in the single wave. Test cases are presented wherein two different wave forcings are simulated: (1) two periodic oscillatory motions and (2) short waves interacting with a solitary wave. The analysis of the two periodic motions indicates that nonlinear effects in the rotational solution may be significant even though nonlinear effects are negligible in the potential forcing. The local differences in the rotational velocity due to the nonlinear vertical convection coupling term are found to be on the order of 30% of the maximum boundary layer velocity for the cases simulated in this paper. This difference is expected to increase with the increase in wave nonlinearity.

  2. Analysis of mechanical strength to fixing the femoral neck fracture in synthetic bone type Asnis

    PubMed Central

    Freitas, Anderson; Lula, Welder Fernandes; de Oliveira, Jonathan Sampaio; Maciel, Rafael Almeida; Souto, Diogo Ranier de Macedo; Godinho, Patrick Fernandes

    2014-01-01

    OBJECTIVE: To analyze the results of biomechanical assays of fixation of Pauwels type III femoral neck fracture in synthetic bone, using 7.5mm cannulated screws in inverted triangle formation, in relation to the control group. METHODS: Ten synthetic bones were used, from a domestic brand, divided into two groups: test and control. In the test group, a 70° tilt osteotomy of the femoral neck was fixated using three cannulated screws in inverted triangle formation. The resistance of this fixation and its rotational deviation were analyzed at 5mm displacement (phase 1) and 10mm displacement (phase 2). The control group was tested in its integrity until the fracture of the femoral neck occurred. The Mann-Whitney test was used for group analysis and comparison. RESULTS: The values in the test group in phase 1, in samples 1-5, showed a mean of 579N and SD =77N. Rotational deviations showed a mean of 3.33°, SD = 2.63°. In phase 2, the mean was 696N and SD =106N. The values of the maximum load in the control group had a mean of 1329N and SD=177N. CONCLUSION: The analysis of mechanical strength between the groups determined a statistically significant lower value in the test group. Level of Evidence III, Control Case. PMID:25246851

  3. Mental Rotation Performance in Primary School Age Children: Are There Gender Differences in Chronometric Tests?

    ERIC Educational Resources Information Center

    Jansen, P.; Schmelter, A.; Quaiser-Pohl, C.; Neuburger, S.; Heil, M.

    2013-01-01

    In contrast to the well documented male advantage in psychometric mental rotation tests, gender differences in chronometric experimental designs are still under dispute. Therefore, a systematic investigation of gender differences in mental rotation performance in primary-school children is presented in this paper. A chronometric mental rotation…

  4. On the Relationship between Solution Strategies in Two Mental Rotation Tasks

    ERIC Educational Resources Information Center

    Janssen, Anne B.; Geiser, Christian

    2010-01-01

    Individual differences in solution strategies have frequently been reported for different measures of mental rotation (MR) ability. In the present study (N=346 German students), we investigated the relationship between solution strategies on two tests commonly used to identify different patterns of strategies: the Mental Rotations Test (MRT;…

  5. Finite-element analysis and modal testing of a rotating wind turbine

    NASA Astrophysics Data System (ADS)

    Carne, T. G.; Lobitz, D. W.; Nord, A. R.; Watson, R. A.

    1982-10-01

    A finite element procedure, which includes geometric stiffening, and centrifugal and Coriolis terms resulting from the use of a rotating coordinate system, was developed to compute the mode shapes and frequencies of rotating structures. Special applications of this capability was made to Darrieus, vertical axis wind turbines. In a parallel development effort, a technique for the modal testing of a rotating vertical axis wind turbine is established to measure modal parameters directly. Results from the predictive and experimental techniques for the modal frequencies and mode shapes are compared over a wide range of rotational speeds.

  6. Finite element analysis and modal testing of a rotating wind turbine

    NASA Astrophysics Data System (ADS)

    Carne, T. G.; Lobitz, D. W.; Nord, A. R.; Watson, R. A.

    A finite element procedure, which includes geometric stiffening, and centrifugal and Coriolis terms resulting from the use of a rotating coordinate system, has been developed to compute the mode shapes and frequencies of rotating structures. Special application of this capability has been made to Darrieus, vertical axis wind turbines. In a parallel development effort, a technique for the modal testing of a rotating vertical axis wind turbine has been established to measure modal parameters directly. Results from the predictive and experimental techniques for the modal frequencies and mode shapes are compared over a wide range of rotational speeds.

  7. Spatially homogeneous rotating world models.

    NASA Technical Reports Server (NTRS)

    Ozsvath, I.

    1971-01-01

    The mathematical problem encountered when looking for the simplest expanding and rotating model of the universe without the compactness condition for the space sections is formulated. The Lagrangian function is derived for four different rotating universes simultaneously. These models correspond in a certain sense to Godel's (1950) ?symmetric case.'

  8. Magnetic island and plasma rotation under external resonant magnetic perturbation in the T-10 tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eliseev, L. G.; Ivanov, N. V., E-mail: ivanov-nv@nrcki.ru; Kakurin, A. M.

    2015-05-15

    Experimental comparison of the m = 2, n = 1 mode and plasma rotation velocities at q = 2 magnetic surface in a wide range of the mode amplitudes is presented. Phase velocity of the mode rotation is measured with a set of poloidal magnetic field sensors located at the inner side of the vacuum vessel wall. Plasma rotation velocity at the q = 2 magnetic surface in the direction of the mode phase velocity is measured with the heavy ion beam probe diagnostics. In the presence of a static Resonant Magnetic Perturbation (RMP), the rotation is irregular that appears as cyclical variations of the mode and plasmamore » instantaneous velocities. The period of these variations is equal to the period of the mode oscillations. In the case of high mode amplitude, the rotation irregularity of the mode is consistent with the rotation irregularity of the resonant plasma layer. On the contrary, the observed rise of the mode rotation irregularity in the case of low mode amplitude occurs without an increase of the rotation irregularity of the resonant plasma layer. The experimental results are simulated and analyzed with the TEAR code based on the two-fluid MHD approximation. Calculated irregularities of the mode and plasma rotation depend on the mode amplitude similar to the experimental data. For large islands, the rotation irregularity is attributed to oscillations of the electromagnetic torque applied to the resonant plasma layer. For small islands, the deviation of the mode rotation velocity from the plasma velocity occurs due to the effect of finite plasma resistivity.« less

  9. Black hole Brownian motion in a rotating environment

    NASA Astrophysics Data System (ADS)

    Lingam, Manasvi

    2018-01-01

    A Langevin equation is set up to model the dynamics of a supermassive black hole (massive particle) in a rotating environment (of light particles), typically the inner region of the galaxy, under the influence of dynamical friction, gravity and stochastic forces. The formal solution is derived, and the displacement and velocity two-point correlation functions are computed. The correlators perpendicular to the axis of rotation are equal to one another and different from those parallel to the axis. By computing this difference, it is suggested that one can, perhaps, observationally determine the magnitude of the rotation. In the case with sufficiently fast rotation, it is suggested that this model can lead to an ejection. If either one of dynamical friction and Eddington accretion is included, it is shown that a near-identical Langevin equation follows, allowing us to treat the two cases in a unified manner. The limitations of the model are also presented and compared against previous results.

  10. Variable displacement blower

    DOEpatents

    Bookout, Charles C.; Stotts, Robert E.; Waring, Douglass R.; Folsom, Lawrence R.

    1986-01-01

    A blower having a stationary casing for rotatably supporting a rotor assembly having a series of open ended chambers arranged to close against the surrounding walls of the casing. Pistons are slidably mounted within each chamber with the center of rotation of the pistons being offset in regard to the center of rotation of the rotor assembly whereby the pistons reciprocate in the chambers as the rotor assembly turns. As inlet port communicates with the rotor assembly to deliver a working substance into the chamber as the pistons approach a top dead center position in the chamber while an outlet port also communicates with the rotor to exhaust the working substance as the pistons approach a bottom dead center position. The displacement of the blower is varied by adjusting the amount of eccentricity between the center of rotation of the pistons and the center of rotation of the rotor assembly.

  11. Methyl Group Internal Rotation in the Pure Rotational Spectrum of 1,1-DIFLUOROACETONE

    NASA Astrophysics Data System (ADS)

    Grubbs, G. S. Grubbs, II; Cooke, S. A.; Groner, P.

    2011-06-01

    We have used chirped pulse Fourier transform microwave spectroscopy to record the pure rotational spectrum of the title molecule. The spectrum was doubled owing to the internal rotation of the methyl group. The spectrum has been assigned and two approaches to the spectral analysis have been performed. In the first case, the A and E components were fit separately using a principal axis method with the SPFIT code of Pickett. In the second case, the A and E states were fit simultaneously using the ERHAM code. For a satisfactory analysis of the spectral data it has been found that the choice of Hamiltonian reduction, i.e. Watson A or S, is very important. The barrier to the internal rotation has been determined to be 261.1(8) Cm-1 and it will be compared to that of acetone and other halogenated acetone species recently studied in our laboratory.

  12. Attitude of Medical Students towards Psychiatry: The case of Jimma University, Southwest Ethiopia.

    PubMed

    Hailesilassie, Hailemariam; Kerebih, Habtamu; Negash, Alemayehu; Girma, Eshetu; Siebeck, Mathias; Tesfaye, Markos

    2017-05-01

    The inability to attract medical graduates to specialize in psychiatry has always been a serious challenge to psychiatry training programs. Therefore, the aim of this study was to assess the attitude of medical students towards psychiatry. A comparative cross-sectional survey was conducted among 122 fourth year medical students of Jimma University. The attitude of medical students towards psychiatry was measured by Attitude toward Psychiatry - 30 (ATP-30). The collected Data were analyzed by SPSS version-20 using independent samples t-test plus bivariate and multivariate logistic regression. The level of significance was determined at 95% confidence interval. Medical students who did not take psychiatry clinical rotation had a higher ATP-30 mean score 55.52(±15.2) indicating positive attitude towards psychiatry than those who completed psychiatry clinical rotation (mean= 49.75 ±10.67). Female medical students had significantly more positive attitude towards psychiatry than males (OR=9.23, 95% CI: 2.32; 36.76). Medical students who did not take psychiatry clinical rotation had more positive attitude towards psychiatry than students who completed the psychiatry clinical rotation (OR=7.58, 95% CI: 2.02; 28.37). Subjective experience of mental illness and reported family history of mental illness significantly predicted positive attitude toward psychiatry. The findings suggest that doing psychiatry rotation might have affected the attitude of medical students towards psychiatry. Future research should assess the experiential factors during psychiatry training of medical students that affect their attitudes. Also, future research needs to evaluate the attitudes of fourth year medical students before and after their psychiatry clinical rotation.

  13. Rotation-vibration interactions in the spectra of polycyclic aromatic hydrocarbons: Quinoline as a test-case species

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pirali, O.; Gruet, S.; Institut des Sciences Moléculaires d’Orsay, UMR8214 CNRS – Université Paris-Sud, Bât. 210, 91405 Orsay cedex

    2015-03-14

    Polycyclic aromatic hydrocarbons (PAHs) are highly relevant for astrophysics as possible, though controversial, carriers of the unidentified infrared emission bands that are observed in a number of different astronomical objects. In support of radio-astronomical observations, high resolution laboratory spectroscopy has already provided the rotational spectra in the vibrational ground state of several molecules of this type, although the rotational study of their dense infrared (IR) bands has only recently become possible using a limited number of experimental set-ups. To date, all of the rotationally resolved data have concerned unperturbed spectra. We presently report the results of a high resolution studymore » of the three lowest vibrational states of quinoline C{sub 9}H{sub 7}N, an N-bearing naphthalene derivative. While the pure rotational ground state spectrum of quinoline is unperturbed, severe complications appear in the spectra of the ν{sub 45} and ν{sub 44} vibrational modes (located at about 168 cm{sup −1} and 178 cm{sup −1}, respectively). In order to study these effects in detail, we employed three different and complementary experimental techniques: Fourier-transform microwave spectroscopy, millimeter-wave spectroscopy, and Fourier-transform far-infrared spectroscopy with a synchrotron radiation source. Due to the high density of states in the IR spectra of molecules as large as PAHs, perturbations in the rotational spectra of excited states should be ubiquitous. Our study identifies for the first time this effect and provides some insights into an appropriate treatment of such perturbations.« less

  14. Black hole spin from wobbling and rotation of the M87 jet and a sign of a magnetically arrested disc

    NASA Astrophysics Data System (ADS)

    Sob'yanin, Denis Nikolaevich

    2018-06-01

    New long-term Very Long Baseline Array observations of the well-known jet in the M87 radio galaxy at 43 GHz show that the jet experiences a sideways shift with an approximately 8-10 yr quasi-periodicity. Such jet wobbling can be indicative of a relativistic Lense-Thirring precession resulting from a tilted accretion disc. The wobbling period together with up-to-date kinematic data on jet rotation opens up the possibility for estimating angular momentum of the central supermassive black hole. In the case of a test-particle precession, the specific angular momentum is J/Mc = (2.7 ± 1.5) × 1014 cm, implying moderate dimensionless spin parameters a = 0.5 ± 0.3 and 0.31 ± 0.17 for controversial gas-dynamic and stellar-dynamic black hole masses. However, in the case of a solid-body-like precession, the spin parameter is much smaller for both masses, 0.15 ± 0.05. Rejecting this value on the basis of other independent spin estimations requires the existence of a magnetically arrested disc in M87.

  15. Rainbows in rotationally inelastic scattering: a comparative study of different model potential surfaces and dynamical approximations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schinke, R.; Korsch, H.J.; Poppe, D.

    1982-12-15

    Rainbow structures in rotationally elastic and inelastic differential cross sections in atom--diatom collisions are investigated by comparison of three model potential energy surfaces labeled I, II, and III which are represented by V(R,..gamma..) = V/sub 0/(R)+V/sub 2/(R)P/sub 2/(cos ..gamma..). The cross sections are calculated within the quantal infinite-order-sudden (IOS) approximation. The anisotropic part V/sub 2/ is the same for all potentials and purely repulsive. The isotropic part V/sub 0/ for potential I is also repulsive and the differential cross sections show the well-studied rotational rainbow structures. Structural changes occur for collisions in potential II and III which have V/sub 0/more » terms being attractive at intermediate and large atom--molecule separations and having well depths of 10% and 25% of the collision energy, respectively. For example, the elastic cross section has no classical rainbow in the case of potential I but three in the case of potential III. The rainbow structures are analyzed within the classical and semiclassical versions of the IOS approximation and interpreted in terms of catastrophe theory. The quantitative comparison of the classical with the quantal IOS cross sections manifests possible quantum effects, i.e., tunneling into nonclassical regions and interference effects due to the superposition of several contributions (up to six in the present study). They can be very prominent and thus we conclude that much caution is needed if experimental data are compared with classical calculations. The accuracy of the IOS approximation is tested by comparison of classical IOS cross sections with cross sections obtained from exact classical trajectory calculations. The agreement is generally good with the exemption of the rainbow region and small angle, rotationally elastic scattering.« less

  16. The K2 M67 Study: Establishing the Limits of Stellar Rotation Period Measurements in M67 with K2 Campaign 5 Data

    NASA Astrophysics Data System (ADS)

    Esselstein, Rebecca; Aigrain, Suzanne; Vanderburg, Andrew; Smith, Jeffrey C.; Meibom, Soren; Van Saders, Jennifer; Mathieu, Robert

    2018-06-01

    The open cluster M67 offers a unique opportunity to measure rotation periods for solar-age stars across a range of masses, potentially filling a critical gap in the understanding of angular momentum loss in older main sequence stars. The observation of M67 by NASA K2 Campaign 5 provided light curves with high enough precision to make this task possible, albeit challenging, as the pointing instability, 75 day observation window, crowded field, and typically low-amplitude signals mean that determining accurate rotation periods on the order of 25–30 days is inherently difficult. Lingering, non-astrophysical signals with power at ≥25 days found in a set of Campaign 5 A and F stars compounds the problem. To achieve a quantitative understanding of the best-case scenario limits for reliable period detection imposed by these inconveniences, we embarked on a comprehensive set of injection tests, injecting 120,000 sinusoidal signals with periods ranging from 5 to 35 days and amplitudes from 0.05% to 3.0% into real Campaign 5 M67 light curves processed using two different pipelines. We attempted to recover the signals using a normalized version of the Lomb–Scargle periodogram and setting a detection threshold. We find that, while the reliability of detected periods is high, the completeness (sensitivity) drops rapidly with increasing period and decreasing amplitude, maxing at a 15% recovery rate for the solar case (i.e., 25 day period, 0.1% amplitude). This study highlights the need for caution in determining M67 rotation periods from Campaign 5 data, but this can be extended to other clusters observed by K2 (and soon, TESS).

  17. Klein-Gordon oscillator with position-dependent mass in the rotating cosmic string spacetime

    NASA Astrophysics Data System (ADS)

    Wang, Bing-Qian; Long, Zheng-Wen; Long, Chao-Yun; Wu, Shu-Rui

    2018-02-01

    A spinless particle coupled covariantly to a uniform magnetic field parallel to the string in the background of the rotating cosmic string is studied. The energy levels of the electrically charged particle subject to the Klein-Gordon oscillator are analyzed. Afterwards, we consider the case of the position-dependent mass and show how these energy levels depend on the parameters in the problem. Remarkably, it shows that for the special case, the Klein-Gordon oscillator coupled covariantly to a homogeneous magnetic field with the position-dependent mass in the rotating cosmic string background has the similar behaviors to the Klein-Gordon equation with a Coulomb-type configuration in a rotating cosmic string background in the presence of an external magnetic field.

  18. Generalisation, decision making, and embodiment effects in mental rotation: A neurorobotic architecture tested with a humanoid robot.

    PubMed

    Seepanomwan, Kristsana; Caligiore, Daniele; Cangelosi, Angelo; Baldassarre, Gianluca

    2015-12-01

    Mental rotation, a classic experimental paradigm of cognitive psychology, tests the capacity of humans to mentally rotate a seen object to decide if it matches a target object. In recent years, mental rotation has been investigated with brain imaging techniques to identify the brain areas involved. Mental rotation has also been investigated through the development of neural-network models, used to identify the specific mechanisms that underlie its process, and with neurorobotics models to investigate its embodied nature. Current models, however, have limited capacities to relate to neuro-scientific evidence, to generalise mental rotation to new objects, to suitably represent decision making mechanisms, and to allow the study of the effects of overt gestures on mental rotation. The work presented in this study overcomes these limitations by proposing a novel neurorobotic model that has a macro-architecture constrained by knowledge held on brain, encompasses a rather general mental rotation mechanism, and incorporates a biologically plausible decision making mechanism. The model was tested using the humanoid robot iCub in tasks requiring the robot to mentally rotate 2D geometrical images appearing on a computer screen. The results show that the robot gained an enhanced capacity to generalise mental rotation to new objects and to express the possible effects of overt movements of the wrist on mental rotation. The model also represents a further step in the identification of the embodied neural mechanisms that may underlie mental rotation in humans and might also give hints to enhance robots' planning capabilities. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. Numerical simulation of rotating stall and surge alleviation in axial compressors

    NASA Astrophysics Data System (ADS)

    Niazi, Saeid

    Axial compression systems are widely used in many aerodynamic applications. However, the operability of such systems is limited at low-mass flow rates by fluid dynamic instabilities. These instabilities lead the compressor to rotating stall or surge. In some instances, a combination of rotating stall and surge, called modified surge, has also been observed. Experimental and computational methods are two approaches for investigating these adverse aerodynamic phenomena. In this study, numerical investigations have been performed to study these phenomena, and to develop control strategies for alleviation of rotating stall and surge. A three-dimensional unsteady Navier-Stokes analysis capable of modeling multistage turbomachinery components has been developed. This method uses a finite volume approach that is third order accurate in space, and first or second order in time. The scheme is implicit in time, permitting the use of large time steps. A one-equation Spalart-Allmaras model is used to model the effects of turbulence. The analysis is cast in a very general form so that a variety of configurations---centrifugal compressors and multistage compressors---may be analyzed with minor modifications to the analysis. Calculations have been done both at design and off-design conditions for an axial compressor tested at NASA Glenn Research Center. At off-design conditions the calculations show that the tip leakage flow becomes strong, and its interaction with the tip shock leads to compressor rotating stall and modified surge. Both global variations to the mass flow rate, associated with surge, and azimuthal variations in flow conditions indicative of rotating stall, were observed. It is demonstrated that these adverse phenomena may be eliminated, and stable operation restored, by the use of bleed valves located on the diffuser walls. Two types of controls were examined: open-loop and closed-loop. In the open-loop case mass is removed at a fixed, preset rate from the diffuser. In the closed-loop case, the rate of bleed is linked to pressure fluctuations upstream of the compressor face. The bleed valve is activated when the amplitude of pressure fluctuations sensed by the probes exceeds a certain range. Calculations show that both types of bleeding eliminate both rotating stall and modified surge, and suppress the precursor disturbances upstream of the compressor face. It is observed that smaller amounts of compressed air need to be removed with the closed-loop control, as compared to open-loop control.

  20. Job Rotation at Cardiff University Library Service: A Pilot Study

    ERIC Educational Resources Information Center

    Earney, Sally; Martins, Ana

    2009-01-01

    This paper presents case study research of a job rotation pilot involving six library assistants in Cardiff University Library Service (ULS). Firstly, it investigates whether job rotation improves motivation and secondly, whether there is an improvement in skills, both technical and "soft". Following a review of the literature,…

  1. 14 CFR 121.279 - Control of engine rotation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Control of engine rotation. 121.279 Section... REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Special Airworthiness Requirements § 121.279 Control... case of turbine engine installations, a means of stopping the rotation need be provided only if the...

  2. Spatio-temporal brain activity related to rotation method during a mental rotation task of three-dimensional objects: an MEG study.

    PubMed

    Kawamichi, Hiroaki; Kikuchi, Yoshiaki; Ueno, Shoogo

    2007-09-01

    During mental rotation tasks, subjects perform mental simulation to solve tasks. However, detailed neural mechanisms underlying mental rotation of three-dimensional (3D) objects, particularly, whether higher motor areas related to mental simulation are activated, remain unknown. We hypothesized that environmental monitoring-a process based on environmental information and is included in motor execution-is as a key factor affecting the utilization of higher motor areas. Therefore, using magnetoencephalography (MEG), we measured spatio-temporal brain activities during two types (two-dimensional (2D) and 3D rotation tasks) of mental rotation of 3D objects. Only the 3D rotation tasks required subjects to mentally rotate objects in a depth plane with visualization of hidden parts of the visual stimuli by acquiring and retrieving 3D information. In cases showing significant differences in the averaged activities at 100-ms intervals between the two rotations, the activities were located in the right dorsal premotor (PMd) at approximately 500 ms. In these cases, averaged activities during 3D rotation were greater than those during 2D rotation, implying that the right PMd activities are related to environmental monitoring. During 3D rotation, higher activities were observed from 200 to 300 ms in the left PMd and from 400 to 700 ms in the right PMd. It is considered that the left PMd is related to primary motor control, whereas the right PMd plays a supplementary role during mental simulation. Further, during 3D rotation, late higher activities related to mental simulation are observed in the right superior parietal lobule (SPL), which is connected to PMd.

  3. Can turned inward patella predict an excess of femoral anteversion during gait in spastic diplegic children?

    PubMed

    Simon, Anne-Laure; Presedo, Ana; Ilharreborde, Brice; Mallet, Cindy; Mazda, Keyvan; Penneçot, Georges-François

    2014-06-01

    Determining patellar orientation in the transverse plane during observational gait analysis is a fundamental aspect of physical examinations. Many physicians consider that an abnormal position of the patella in the transverse planes is only explained by a rotational abnormality of the proximal femur. A total of 188 spastic diplegic children with cerebral palsy were reviewed (376 lower limbs). The physical examination included observation of patellar orientation at midstride and measuring femoral anteversion (FA). All patients also underwent 3-dimensional (3D) computerized gait analysis of pelvic and hip rotation kinematics. Observational gait analysis and videotapes found 103 children (206 lower limbs) with inturned patella at midstance. Kinematic data from 3D gait analysis showed that the visual impression of turned inward patella was erroneous in 48 limbs. Of the remaining 158 lower limbs, 117 (74%) exhibited excessive FA and 41 (26%) did not. Of the 117 with excessive FA, kinematics showed only 66 (56%) with excessive internal hip rotation (with or without excessive internal pelvic rotation). Of the 41 lower limbs without excessive FA, 25 were explained by excessive internal pelvic rotation and 16 were explained by excessive internal hip rotation (isolated spasticity and/or contracture of internal rotator muscles). Turned inward patella was caused by isolated excessive internal pelvic rotation in 48%, excessive internal hip rotation in 35% (including 44 cases with excessive FA and 12 cases with isolated spasticity and/or contracture of internal hip rotators), and excessive internal hip rotation combined with excessive internal pelvic rotation in 17%. Excessive FA was not the only cause of turned inward patella gait and could not explain this gait anomaly by itself. Excessive internal pelvic rotation was the most frequent cause of turned inward patella gait. Level IV.

  4. POPLITEUS STRAIN WITH CONCURRENT DELTOID LIGAMENT SPRAIN IN AN ELITE SOCCER ATHLETE: A CASE REPORT

    PubMed Central

    Beaumont, Josh; Tarnay, Lorena; Silvers, Holly

    2013-01-01

    Study Design: Case Report (Differential diagnosis) Background and Purpose: Differential diagnosis of knee pathology after trauma may be difficult when diagnosing an isolated popliteus strain and concurrent medial deltoid ligament sprain. Upon a thorough search of the published literature, the authors found no reports delineating a popliteus strain in professional soccer in the United States. The joints most affected by injury in soccer players are the knee and ankle joints. The purpose of this case report is to describe the presentation of and difficulties encountered in diagnosing a popliteus strain in a Major League Soccer athlete. Case Description: During an in-season away game, an outside defender was slide-tackled from behind when his right shank was caught in an externally rotated position underneath himself and the opposing player. The initial point of contact was made to the proximal third of the posterior right shank with an anteromedially directed force. The medial longitudinal arch of the foot was forced into a more midfoot pronated position and the subtalar joint was forced into eversion. Diagnosis: The athlete was diagnosed with a moderate strain of the right popliteus muscle with a concurrent medial deltoid ligament sprain of the right ankle. This mechanism of injury, pain with passive knee flexion and internal rotation during McMurray's test, pain with Garrick's Test and magnetic resonance imaging (MRI) study confirmed the diagnosis. The athlete returned to full ninety-minute game participation after an intensive 15-day rehabilitation program. Discussion: This case is unique because the injury manifested itself at multiple joints and specifically involved the popliteus muscle. The mechanism of injury can be associated with many other soft tissue injuries to the knee, and thus, may not lead the clinician initially to consider the diagnosis of a popliteus strain. Diagnosis of this entity may be difficult due to the possible shared attachment of the popliteus muscle to the lateral meniscus, and the lack of available testing methods to assess damage to the popliteus muscle. Level of Evidence: Level 5 PMID:24175131

  5. Assessment of Durability of Online and Multisensory Learning Using an Ophthalmology Model.

    PubMed

    Lippa, Linda Mottow; Anderson, Craig L

    2015-10-01

    To explore the impact of online learning and multisensory small-group teaching on acquisition and retention of specialty knowledge and diagnostic skills during a third-year family medicine rotation. Exploratory, observational, longitudinal, and multiple-skill measures. Two medical school classes (n = 199) at a public medical school in California. Students engaged in online self-study, small-group interactive diagnostic sessions, picture identification of critical pathologic features, and funduscopic simulator examinations. The authors compared performance on testing immediately after online learning with testing at end-rotation, as well as picture identification versus simulator diagnostic ability in students with (n = 94) and without (n = 105) practice tracing contours on whiteboard projections of those same slides depicting fundus pathologic features of common systemic diseases. Picture identification, accuracy of funduscopic descriptions, online module post-tests, and end-rotation tests. Proprioceptive reinforcement of fundus pattern recognition significantly reduced the need for remediation for misdiagnosing optic disc edema during end-rotation funduscopic simulator testing, but it had no effect on fundus pattern recognition or diagnostic ability overall. Near-perfect immediate online post-test scores contrasted sharply with poor end-rotation scores on an in-house test (average, 59.4%). Rotation timing was not a factor because the patterns remained consistent throughout the academic school year. Neither multisensory teaching nor online self-study significantly improved retention of ophthalmic knowledge and diagnostic skills by the end of a month-long third-year rotation. Timing such training closer to internship when application is imminent may enhance students' appreciation for its value and perhaps may improve retention. Pulsed quizzes over time also may be necessary to motivate students to retain the knowledge gained. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. Call for NASA Mission Supporting Observations

    NASA Astrophysics Data System (ADS)

    Binzel, Richard P.

    2018-04-01

    Lightcurve observations are requested to support NASA missions planned for launch to study main-belt and Trojan asteroids. In some cases, the rotations of the target asteroids are unknown. In other cases, the periods are well established and ongoing measurements will deliver the precision needed to deduce the rotation phase at the time of encounter more than a decade away.

  7. Electrohydrodynamic interaction of spherical particles under Quincke rotation.

    PubMed

    Das, Debasish; Saintillan, David

    2013-04-01

    Weakly conducting dielectric particles suspended in a dielectric liquid of higher conductivity can undergo a transition to spontaneous sustained rotation when placed in a sufficiently strong dc electric field. This phenomenon of Quincke rotation has interesting implications for the rheology of these suspensions, whose effective viscosity can be controlled and reduced by application of an external field. While previous models based on the rotation of isolated particles have provided accurate estimates for this viscosity reduction in dilute suspensions, discrepancies have been reported in more concentrated systems where particle-particle interactions are likely significant. Motivated by this observation, we extend the classic description of Quincke rotation based on the Taylor-Melcher leaky dielectric model to account for pair electrohydrodynamic interactions between two identical spheres using the method of reflections. A coupled system of evolution equations for the dipole moments and angular velocities of the spheres is derived that accounts for electric dipole-dipole interactions and hydrodynamic rotlet interactions up to order O(R(-5)), where R is the separation distance between the spheres. A linear stability analysis of this system shows that interactions modify the value of the critical electric field for the onset of Quincke rotation: both electric and hydrodynamic interactions can either stabilize or destabilize the system depending on the orientation of the spheres, but the leading effect of interactions on the onset of rotation is hydrodynamic. We also analyze the dynamics in the nonlinear regime by performing numerical simulations of the governing equations. In the case of a pair of spheres that are fixed in space, we find that particle rotations always synchronize in magnitude at long times, though the directions of rotation of the spheres need not be the same. The steady-state angular velocity magnitude depends on the configuration of the spheres and electric field strength and agrees very well with an asymptotic estimate derived for corotating spheres. In the case of freely-suspended spheres, dipolar interactions are observed to lead to a number of distinct behaviors depending on the initial relative configuration of the spheres and on any infinitesimal initial perturbation introduced in the system: in some cases the spheres slowly separate in space while steadily rotating, while in other cases they pair up and either corotate or counterrotate depending on their orientation relative to the field.

  8. Electrohydrodynamic interaction of spherical particles under Quincke rotation

    NASA Astrophysics Data System (ADS)

    Das, Debasish; Saintillan, David

    2013-04-01

    Weakly conducting dielectric particles suspended in a dielectric liquid of higher conductivity can undergo a transition to spontaneous sustained rotation when placed in a sufficiently strong dc electric field. This phenomenon of Quincke rotation has interesting implications for the rheology of these suspensions, whose effective viscosity can be controlled and reduced by application of an external field. While previous models based on the rotation of isolated particles have provided accurate estimates for this viscosity reduction in dilute suspensions, discrepancies have been reported in more concentrated systems where particle-particle interactions are likely significant. Motivated by this observation, we extend the classic description of Quincke rotation based on the Taylor-Melcher leaky dielectric model to account for pair electrohydrodynamic interactions between two identical spheres using the method of reflections. A coupled system of evolution equations for the dipole moments and angular velocities of the spheres is derived that accounts for electric dipole-dipole interactions and hydrodynamic rotlet interactions up to order O(R-5), where R is the separation distance between the spheres. A linear stability analysis of this system shows that interactions modify the value of the critical electric field for the onset of Quincke rotation: both electric and hydrodynamic interactions can either stabilize or destabilize the system depending on the orientation of the spheres, but the leading effect of interactions on the onset of rotation is hydrodynamic. We also analyze the dynamics in the nonlinear regime by performing numerical simulations of the governing equations. In the case of a pair of spheres that are fixed in space, we find that particle rotations always synchronize in magnitude at long times, though the directions of rotation of the spheres need not be the same. The steady-state angular velocity magnitude depends on the configuration of the spheres and electric field strength and agrees very well with an asymptotic estimate derived for corotating spheres. In the case of freely-suspended spheres, dipolar interactions are observed to lead to a number of distinct behaviors depending on the initial relative configuration of the spheres and on any infinitesimal initial perturbation introduced in the system: in some cases the spheres slowly separate in space while steadily rotating, while in other cases they pair up and either corotate or counterrotate depending on their orientation relative to the field.

  9. Counter-rotating accretion discs

    NASA Astrophysics Data System (ADS)

    Dyda, S.; Lovelace, R. V. E.; Ustyugova, G. V.; Romanova, M. M.; Koldoba, A. V.

    2015-01-01

    Counter-rotating discs can arise from the accretion of a counter-rotating gas cloud on to the surface of an existing corotating disc or from the counter-rotating gas moving radially inwards to the outer edge of an existing disc. At the interface, the two components mix to produce gas or plasma with zero net angular momentum which tends to free-fall towards the disc centre. We discuss high-resolution axisymmetric hydrodynamic simulations of viscous counter-rotating discs for the cases where the two components are vertically separated and radially separated. The viscosity is described by an isotropic α-viscosity including all terms in the viscous stress tensor. For the vertically separated components, a shear layer forms between them and the middle part of this layer free-falls to the disc centre. The accretion rates are increased by factors of ˜102-104 over that for a conventional disc rotating in one direction with the same viscosity. The vertical width of the shear layer and the accretion rate are strongly dependent on the viscosity and the mass fraction of the counter-rotating gas. In the case of radially separated components where the inner disc corotates and the outer disc rotates in the opposite direction, a gap between the two components opens and closes quasi-periodically. The accretion rates are ≳25 times larger than those for a disc rotating in one direction with the same viscosity.

  10. Solitary waves in shallow water hydrodynamics and magnetohydrodynamics in rotating spherical coordinates

    NASA Astrophysics Data System (ADS)

    London, Steven D.

    2018-01-01

    In a recent paper (London, Geophys. Astrophys. Fluid Dyn. 2017, vol. 111, pp. 115-130, referred to as L1), we considered a perfect electrically conducting rotating fluid in the presence of an ambient toroidal magnetic field, governed by the shallow water magnetohydrodynamic (MHD) equations in a modified equatorial ?-plane approximation. In conjunction with a WKB type approximation, we used a multiple scale asymptotic scheme, previously developed by Boyd (J. Phys. Oceanogr. 1980, vol. 10, pp. 1699-1717) for equatorial solitary hydrodynamic waves, and found solitary MHD waves. In this paper, as in L1, we apply a WKB type approximation in order to extend the results of L1 from the modified ?-plane to the full spherical geometry. We have included differential rotation in the analysis in order to make the results more relevant to the solar case. In addition, we consider the case of hydrodynamic waves on the rotating sphere in the presence of a differential rotation intended to roughly model the varying large scale currents in the oceans and atmosphere. In the hydrodynamic case, we find the usual equatorial solitary waves as found by Boyd, as well as waves in bands away from the equator for sufficiently strong currents. In the MHD case, we find basically the same equatorial waves found in L1. L1 also found non-equatorial modes; no such modes are found in the full spherical geometry.

  11. Case report - calcification of the medial collateral ligament of the knee with simultaneous calcifying tendinitis of the rotator cuff.

    PubMed

    Kamawal, Yama; Steinert, Andre F; Holzapfel, Boris M; Rudert, Maximilian; Barthel, Thomas

    2016-07-13

    Calcification of the medial collateral ligament (MCL) of the knee is a very rare disease. We report on a case of a patient with a calcifying lesion within the MCL and simultaneous calcifying tendinitis of the rotator cuff in both shoulders. Calcification of the MCL was diagnosed both via x-ray and magnetic resonance imaging (MRI) and was successfully treated surgically. Calcifying tendinitis of the rotator cuff was successfully treated applying conservative methods. This is the first case report of a patient suffering from both a calcifying lesion within the medial collateral ligament and calcifying tendinitis of the rotator cuff in both shoulders. Clinical symptoms, radio-morphological characteristics and macroscopic features were very similar and therefore it can be postulated that the underlying pathophysiology is the same in both diseases. Our experience suggests that magnetic resonance imaging and x-ray are invaluable tools for the diagnosis of this inflammatory calcifying disease of the ligament, and that surgical repair provides a good outcome if conservative treatment fails. It seems that calcification of the MCL is more likely to require surgery than calcifying tendinitis of the rotator cuff. However, the exact reason for this remains unclear to date.

  12. Influence of third-degree geometric nonlinearities on the vibration and stability of pretwisted, preconed, rotating blades

    NASA Technical Reports Server (NTRS)

    Subrahmanyam, K. B.; Kaza, K. R. V.

    1986-01-01

    The governing coupled flapwise bending, edgewise bending, and torsional equations are derived including third-degree geometric nonlinear elastic terms by making use of the geometric nonlinear theory of elasticity in which the elongations and shears are negligible compared to unity. These equations are specialized for blades of doubly symmetric cross section with linear variation of pretwist over the blade length. The nonlinear steady state equations and the linearized perturbation equations are solved by using the Galerkin method, and by utilizing the nonrotating normal modes for the shape functions. Parametric results obtained for various cases of rotating blades from the present theoretical formulation are compared to those produced from the finite element code MSC/NASTRAN, and also to those produced from an in-house experimental test rig. It is shown that the spurious instabilities, observed for thin, rotating blades when second degree geometric nonlinearities are used, can be eliminated by including the third-degree elastic nonlinear terms. Furthermore, inclusion of third degree terms improves the correlation between the theory and experiment.

  13. Internal performance of a nonaxisymmetric nozzle with a rotating upper flap and a center-pivoted lower flap

    NASA Technical Reports Server (NTRS)

    Wing, David J.; Leavitt, Laurence D.; Re, Richard J.

    1993-01-01

    An investigation was conducted at wind-off conditions in the static-test facility of the Langley 16-Foot Transonic Tunnel to determine the internal performance characteristics of a single expansion-ramp nozzle with thrust-vectoring capability to 105 degrees. Thrust vectoring was accomplished by the downward rotation of an upper flap with adaptive capability for internal contouring and a corresponding rotation of a center-pivoted lower flap. The static internal performance of configurations with pitch thrust-vector angles of 0 degrees, 60 degrees, and 105 degrees each with two throat areas, was investigated. The nozzle pressure ratio was varied from 1.5 to approximately 8.0 (5.0 for the maximum throat area configurations). Results of this study indicated that the nozzle configuration of the present investigation, when vectored, provided excellent flow-turning capability with relatively high levels of internal performance. In all cases, the thrust vector angle was a function of the nozzle pressure ratio. This result is expected because the flow is bounded by a single expansion surface on both vectored- and unvectored-nozzle geometries.

  14. A new potential energy surface for vibration-vibration coupling in HF-HF collisions. Formulation and quantal scattering calculations

    NASA Astrophysics Data System (ADS)

    Schwenke, David W.; Truhlar, Donald G.

    1988-04-01

    We present new ab initio calculations of the HF-HF interaction potential for the case where both molecules are simultaneously displaced from their equilibrium internuclear distance. These and previous ab initio calculations are then fit to a new analytic representation which is designed to be efficient to evaluate and to provide an especially faithful account of the forces along the vibrational coordinates. We use the new potential for two sets of quantal scattering calculations for collisions in three dimensions with total angular momentum zero. First we test that the angular harmonic representation of the anisotropy is adequate by comparing quantal rigid rotator calculations to those carried out for potentials involving higher angular harmonics and for which the expansion in angular harmonics is systematically increased to convergence. Then we carry out large-scale quantal calculations of vibration-vibration energy transfer including the coupling of both sets of vibrational and rotational coordinates. These calculations indicate that significant rotational energy transfer accompanies the vibration-to-vibration energy transfer process.

  15. Analysis of a spacecraft instrument ball bearing assembly lubricated by a perfluoroalkylether

    NASA Technical Reports Server (NTRS)

    Morales, W.; Jones, W. R., Jr.; Buckley, D. H.

    1986-01-01

    An analysis of a spacecraft instrument ball bearing assembly, subjected to a scanning life test, was performed to determine the possible case of rotational problems involving these units aboard several satellites. The analysis indicated an ineffective transfer of a fluorinated liquid lubricant from a phenolic retainer to the bearing balls. Part of the analysis led to a novel HPLC separation method employing a fluorinated mobile phase in conjunction with silica based size exclusion columns.

  16. Intra- and interrater reliability of the 'lumbar-locked thoracic rotation test' in competitive swimmers ages 10 through 18 years.

    PubMed

    Feijen, Stef; Kuppens, Kevin; Tate, Angela; Baert, Isabel; Struyf, Thomas; Struyf, Filip

    2018-04-17

    Measuring thoracic spine mobility can be of interest to competitive swimmers as it has been associated with shoulder girdle function and scapular position in subjects with and without shoulder pain. At present, no reliability data of thoracic spine mobility measurements are available in the swimming population. This study aims to evaluate the within-session intra- and interrater reliability of the "lumbar-locked rotation test" for thoracic spine rotation in competitive swimmers aged 10 to 18 years. This reliability study is part of a larger prospective cohort study investigating potential risk factors for the development of shoulder pain in competitive swimmers. Within-session, intra- and inter-rater reliability. Competitive swimming clubs in Belgium. 21 competitive swimmers. Intra- and inter-rater reliability of the lumbar-locked thoracic rotation test. Intraclass correlation coefficients (ICCs) ranged from 0.91 (95% CI 0.78 to 0.96) to 0.96 (0.89-0.98) for intra-rater reliability. Results for inter-rater reliability ranged from 0.89 (0.72-0.95) to 0.86 (0.65-0.94) respectively for right and left thoracic rotation. Results suggest good to excellent reliability of the lumbar-locked thoracic rotation test, indicating this test can be used reliably in clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. High velocity impact on composite link of aircraft wing flap mechanism

    NASA Astrophysics Data System (ADS)

    Heimbs, Sebastian; Lang, Holger; Havar, Tamas

    2012-12-01

    This paper describes the numerical investigation of the mechanical behaviour of a structural component of an aircraft wing flap support impacted by a wheel rim fragment. The support link made of composite materials was modelled in the commercial finite element code Abaqus/Explicit, incorporating intralaminar and interlaminar failure modes by adequate material models and cohesive interfaces. Validation studies were performed step by step using quasi-static tensile test data and low velocity impact test data. Finally, high velocity impact simulations with a metallic rim fragment were performed for several load cases involving different impact angles, impactor rotation and pre-stress. The numerical rim release analysis turned out to be an efficient approach in the development process of such composite structures and for the identification of structural damage and worst case impact loading scenarios.

  18. Effects of reset stators and a rotating, grooved stator hub on performance of a 1.92-pressure-ratio compressor stage

    NASA Technical Reports Server (NTRS)

    Lewis, G. W., Jr.; Urasek, D. C.; Reid, L.

    1977-01-01

    The overall performance and blade-element performance of a transonic fan stage are presented for two modified test configurations and are compared with the unmodified stage. Tests were conducted with reset stators 2 deg open and reset stators with a rotating grooved stator hub. Detailed radial and circumferential (behind stator) surveys of the flow conditions were made over the stable operating range at rotative speeds of 70, 90, and 100 percent of design speed. Reset stator blade tests indicated a small increase in stage efficiency, pressure ratio, and maximum weight flow at each speed. Performance with reset stators and a rotating, grooved stator hub resulted in an additional increase in stage efficiency and pressure ratio at all speeds. The rotating grooved stator hub reduced hub losses considerably.

  19. [Surgical treatment of pronation and supination external rotation trimalleolar fractures].

    PubMed

    Xu, Ye-qing; Zhan, Bei-lei; He, Fei-xiong; Wei, Hong-da

    2008-04-01

    To explore the operative method and its clinical effects of pronation and supination external rotation trimalleolar fractures. From March 2000 to July 2006,42 patients of the pronation and supination external rotation trimalleolar fractures treated with open reduction and internal fixation. Thirty-one were males and 11 were females,with an average age of 40.5 years (from 19 to 76 years). Four cases were open fractures and 38 cases close fractures. The fractures were classified as pronation-external rotation (grade IV) injury in 18 cases and supination-external rotation (grade IV)in 24 cases according to the system of Lauge-Hansen. The time of injury to operation was 2 hours to 27 days. The medial, lateral and posterior malleolus were exposed by standard anteromedial and Gatellier-Chastang approaches. The reduction and internal fixation started with the posterior,then the medial and the lateral malleolus and distal tibiofibular syndesmosis in sequence. The anteroposterior, lateral and mostise X-ray films were taken after operation. All the patients were followed up for an average time of 13.5 months(from 6 to 24 months). The time of union was from 12 to 16 weeks. The results were excellent in 20,good in 16, fair in 4 and poor in 2 cases according to Baird-Jackson ankle scoring system based on pain, stability, walking ability,range of motion and radiological manifestations. The excellent and good rate was 85.7%. There were no infection,malunion and nonunion of the fractures except that the inserted screw to distal tibiofibular syndesmosis was broken in 1 case. The key of operative treatment is to restore the anatomy of ankle and to regain the ankle function maximally.

  20. Towards 3D mapping of BO₆ octahedron rotations at perovskite heterointerfaces, unit cell by unit cell

    DOE PAGES

    He, Qian; Ishikawa, Ryo; Lupini, Andrew R.; ...

    2015-07-15

    The rich functionalities in the ABO₃ perovskite oxides originate at least partly from the ability of the corner-connected BO₆ octahedral network to host a large variety of cations through distortions and rotations. Characterizing these rotations, which significantly affect both fundamental aspects of materials behavior and possible applications, remains a major challenge. In this work, we have developed a unique method of investigating BO₆ rotation patterns in complex oxides ABO₃ with unit cell resolution at heterointerfaces, where novel properties often emerge. Our method involves column shape analysis in annular bright field - scanning transmission electron microscope images of the ABO₃ heterointerfacesmore » taken in specific orientations. The rotating phase of BO₆ octahedra can be identified for all three spatial dimensions without the need of case-by-case simulation. In several common rotation systems, it is now possible to quantitatively measure all three rotation angles. With this method, we examined interfaces between perovskites with distinct tilt systems as well as interfaces between tilted and untilted perovskites, identifying an unusual coupling behavior at the CaTiO₃/LSAT interface. We believe this unique method will significantly improve our knowledge of the complex oxide heterointerfaces.« less

  1. QED Effects in Molecules: Test on Rotational Quantum States of H2

    NASA Astrophysics Data System (ADS)

    Salumbides, E. J.; Dickenson, G. D.; Ivanov, T. I.; Ubachs, W.

    2011-07-01

    Quantum electrodynamic effects have been systematically tested in the progression of rotational quantum states in the XΣg+1, v=0 vibronic ground state of molecular hydrogen. High-precision Doppler-free spectroscopy of the EFΣg+1-XΣg+1 (0,0) band was performed with 0.005cm-1 accuracy on rotationally hot H2 (with rotational quantum states J up to 16). QED and relativistic contributions to rotational level energies as high as 0.13cm-1 are extracted, and are in perfect agreement with recent calculations of QED and high-order relativistic effects for the H2 ground state.

  2. The Effects of Posterior Rotator Cuff Cable Tears on Glenohumeral Biomechanics in a Cadaveric Model of the Throwing Shoulder

    PubMed Central

    Photopoulos, Christos Demetris; ElAttrache, Neal S.; Doermann, Alex; Akeda, Masaki; McGarry, Michelle H.; Lee, Thay Q.

    2017-01-01

    Objectives: The rotator cuff cable has been postulated to be the primary load bearing substructure of the superior part of the rotator cuff. Tears of the posterior rotator cable are frequently seen in overhead throwing athletes. Although the biomechanical significance of the anterior rotator cable has been well described, our current understanding of the relevance of the posterior cable is limited. The purpose of this study was to examine how partial-thickness tears and full-thickness tears of the posterior rotator cable would alter glenohumeral biomechanics and kinematics in cadaveric shoulder models. Methods: Eight fresh-frozen cadaveric shoulder specimens were prepared and tested. To simulate the sequence of glenohumeral positions during the throwing motion, specimens were mounted on a custom shoulder testing system with the humerus positioned at 90° of abduction (30° scapular upward rotation, 60° glenohumeral abduction) and tested at 30, 60, 90, and 120 degrees of external rotation. After a circumferential capsulotomy was performed, rotator cuff muscles were loaded based on physiologic cross-sectional area ratios, and testing for each specimen was performed on each the following three conditions: intact posterior cable, partial-thickness (50%) articular-sided posterior cable tear, and full-thickness posterior cable tear. Primary outcome measures tested for each condition under the various degrees of glenohumeral rotation were: 1) anterior and total glenohumeral translation after application of a 30N anterior force; 2) path of glenohumeral articulation; 3) glenohumeral joint force. Results: With a 30N anterior force at 120° of external rotation, there was a significant increase in anterior glenohumeral translation between intact and full-thickness tear specimens (7.28±2.00mm and 17.49±3.75mm, respectively; p<0.05). Similarly, total joint translation at 120° of external rotation significantly increased between intact and full-thickness tear specimens (10.37±3.18mm and 23.37±5.05mm, respectively; p<0.05). No significant differences were apparent at other degrees of rotation (30, 60, 90 degrees), or with partial-thickness tears. Changes in the path of glenohumeral articulation were likewise most evident at 120° of external rotation, with a progressively anterior, inferior, and lateral shift in articulation with sequential sectioning of the posterior cable. Lastly, with regards to alterations in glenohumeral joint force, no significant changes were seen in any of the conditions. Conclusion: In this cadaveric shoulder model of the throwing shoulder, tears of the posterior rotator cuff cable lead to altered glenohumeral biomechanics and kinematics. These changes were most profound at 120° of external rotation, suggesting the importance of an intact posterior cable as a potential stabilizer during the late-cocking phase of throwing.

  3. Job Rotation Designed to Prevent Musculoskeletal Disorders and Control Risk in Manufacturing Industries: A Systematic Review

    PubMed Central

    Padula, Rosimeire Simprini; Comper, Maria Luiza Caires; Sparer, Emily H.; Dennerlein, Jack T

    2017-01-01

    To better understand job rotation in the manufacturing industry, we completed a systematic review asking the following questions: 1) How do job-rotation programs impact work-related musculoskeletal disorders (MSDs) and related risk control for these MSDs, as well as psychosocial factors? and 2) How best should the job rotation programs be designed? We searched MEDLINE, EMBASE, Business Source Premier, ISI Web of Knowledge, CINAHL, PsyINFO, Scopus, and SciELO databases for articles published in peer-reviewed journals. Eligible studies were examined by two independent reviewers for relevance (population of manufacturing workers, outcomes of musculoskeletal disease, physical factors, psychosocial factors, and strategies used in job-rotation implantation) and methodological quality rating. From 10,809 potential articles, 71 were read for full text analysis. Of the 14 studies included for data extraction, two were non-randomized control trial studies, one was a case-control study, and 11 were cross-sectional comparisons. Only one, with a case-control design, was scored with good methodological quality. Currently, weak evidence exists supporting job rotation as a strategy for the prevention and control of musculoskeletal disorders. Job rotation did not appear to reduce the exposure of physical risk factors; yet, there are positive correlations between job rotation and higher job satisfaction. Worker training has been described as a crucial component of a successful job-rotation program. The studies reported a range of parameters used to implement and measure job-rotation programs. More rigorous studies are needed to better understand the full impact of job rotation on production and health. PMID:27633235

  4. Rotational elasticity

    NASA Astrophysics Data System (ADS)

    Vassiliev, Dmitri

    2017-04-01

    We consider an infinite three-dimensional elastic continuum whose material points experience no displacements, only rotations. This framework is a special case of the Cosserat theory of elasticity. Rotations of material points are described mathematically by attaching to each geometric point an orthonormal basis that gives a field of orthonormal bases called the coframe. As the dynamical variables (unknowns) of our theory, we choose the coframe and a density. We write down the general dynamic variational functional for our rotational theory of elasticity, assuming our material to be physically linear but the kinematic model geometrically nonlinear. Allowing geometric nonlinearity is natural when dealing with rotations because rotations in dimension three are inherently nonlinear (rotations about different axes do not commute) and because there is no reason to exclude from our study large rotations such as full turns. The main result of the talk is an explicit construction of a class of time-dependent solutions that we call plane wave solutions; these are travelling waves of rotations. The existence of such explicit closed-form solutions is a non-trivial fact given that our system of Euler-Lagrange equations is highly nonlinear. We also consider a special case of our rotational theory of elasticity which in the stationary setting (harmonic time dependence and arbitrary dependence on spatial coordinates) turns out to be equivalent to a pair of massless Dirac equations. The talk is based on the paper [1]. [1] C.G.Boehmer, R.J.Downes and D.Vassiliev, Rotational elasticity, Quarterly Journal of Mechanics and Applied Mathematics, 2011, vol. 64, p. 415-439. The paper is a heavily revised version of preprint https://arxiv.org/abs/1008.3833

  5. Reversal of orbital angular momentum arising from an extreme Doppler shift.

    PubMed

    Gibson, Graham M; Toninelli, Ermes; Horsley, Simon A R; Spalding, Gabriel C; Hendry, Euan; Phillips, David B; Padgett, Miles J

    2018-04-10

    The linear Doppler shift is familiar as the rise and fall in pitch of a siren as it passes by. Less well known is the rotational Doppler shift, proportional to the rotation rate between source and receiver, multiplied by the angular momentum carried by the beam. In extreme cases the Doppler shift can be larger than the rest-frame frequency and for a red shift, the observed frequency then becomes "negative." In the linear case, this effect is associated with the time reversal of the received signal, but it can be observed only with supersonic relative motion between the source and receiver. However, the rotational case is different; if the radius of rotation is smaller than the wavelength, then the velocities required to observe negative frequencies are subsonic. Using an acoustic source at [Formula: see text]100 Hz we create a rotational Doppler shift larger than the laboratory-frame frequency. We observe that once the red-shifted wave passes into the "negative frequency" regime, the angular momentum associated with the sound is reversed in sign compared with that of the laboratory frame. These low-velocity laboratory realizations of extreme Doppler shifts have relevance to superoscillatory fields and offer unique opportunities to probe interactions with rotating bodies and aspects of pseudorelativistic frame translation. Copyright © 2018 the Author(s). Published by PNAS.

  6. Diagnostic value of clinical tests for degenerative rotator cuff disease in medical practice.

    PubMed

    Lasbleiz, S; Quintero, N; Ea, K; Petrover, D; Aout, M; Laredo, J D; Vicaut, E; Bardin, T; Orcel, P; Beaudreuil, J

    2014-06-01

    To assess the diagnostic value of clinical tests for degenerative rotator cuff disease (DRCD) in medical practice. Patients with DRCD were prospectively included. Eleven clinical tests of the rotator cuff have been done. One radiologist performed ultrasonography (US) of the shoulder. Results of US were expressed as normal tendon, tendinopathy or full-thickness tear (the reference). For each clinical test and each US criteria, sensitivity, specificity, negative predictive value and positive predictive value, accuracy, negative likelihood ratio (NLR) and positive likelihood ratio (PLR) were calculated. Clinical relevance was defined as PLR ≥2 and NLR ≤0.5. For 35 patients (39 shoulders), Jobe (PLR: 2.08, NLR: 0.31) and full-can (2, 0.5) test results were relevant for diagnosis of supraspinatus tears and resisted lateral rotation (2.42, 0.5) for infraspinatus tears, with weakness as response criteria. The lift-off test (8.50, 0.27) was relevant for subscapularis tears with lag sign as response criteria. Yergason's test (3.7, 0.41) was relevant for tendinopathy of the long head of the biceps with pain as a response criterion. There was no relevant clinical test for diagnosis of tendinopathy of supraspinatus, infraspinatus or subscapularis. Five of 11 clinical tests were relevant for degenerative rotator cuff disease. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  7. Pre-Test Assessment of the Use Envelope of the Normal Force of a Wind Tunnel Strain-Gage Balance

    NASA Technical Reports Server (NTRS)

    Ulbrich, N.

    2016-01-01

    The relationship between the aerodynamic lift force generated by a wind tunnel model, the model weight, and the measured normal force of a strain-gage balance is investigated to better understand the expected use envelope of the normal force during a wind tunnel test. First, the fundamental relationship between normal force, model weight, lift curve slope, model reference area, dynamic pressure, and angle of attack is derived. Then, based on this fundamental relationship, the use envelope of a balance is examined for four typical wind tunnel test cases. The first case looks at the use envelope of the normal force during the test of a light wind tunnel model at high subsonic Mach numbers. The second case examines the use envelope of the normal force during the test of a heavy wind tunnel model in an atmospheric low-speed facility. The third case reviews the use envelope of the normal force during the test of a floor-mounted semi-span model. The fourth case discusses the normal force characteristics during the test of a rotated full-span model. The wind tunnel model's lift-to-weight ratio is introduced as a new parameter that may be used for a quick pre-test assessment of the use envelope of the normal force of a balance. The parameter is derived as a function of the lift coefficient, the dimensionless dynamic pressure, and the dimensionless model weight. Lower and upper bounds of the use envelope of a balance are defined using the model's lift-to-weight ratio. Finally, data from a pressurized wind tunnel is used to illustrate both application and interpretation of the model's lift-to-weight ratio.

  8. Wear studies of all UHMWPE couples under various bio-tribological conditions.

    PubMed

    Joyce, T J; Unsworth, A

    2004-01-01

    Wear tests were undertaken in which ultra high molecular weight polyethylene (UHMWPE) was rubbed against itself. Tests primarily employed a pin-on-plate wear test machine, with distilled water, Ringer solution and dilute bovine serum being used as the lubricants. Loads of 10N and 40N were employed, and some test pins had a rotational motion added. In all cases wear was high, with mean wear factors of up to 91 10 -6 mm3/Nm being measured, but the addition of rotation reduced the amount of material worn from the test plates. In the presence of bovine serum and under reciprocation only, pin wear was relatively low. With bovine serum as the lubricant, total mean wear factors for the UHMWPE couples were calculated to be in the range of 35 to 58 10-6mm3/Nm. Therefore the pin-on-plate tests showed that the choice of lubricant as well as the motion applied to the test pin had a significant influence on the wear volumes measured. A two-piece UHMWPE 'prosthesis' with matching hemispherical faces was fabricated and tested on a finger simulator. Distilled water was used as the lubricant and wear factors were found to be greater for the metacarpal component, 21 10 -6mm3/Nm, than the phalangeal component, 3 10-6mm3/Nm, after ten million cycles of testing. This result paralleled the greater wear seen by the plate than by the pin in the pin-on-plate tests under reciprocating motion. (Journal of Applied Biomaterials & Biomechanics 2004; 2: 29-34).

  9. Rotation curve for the Milky Way galaxy in conformal gravity

    NASA Astrophysics Data System (ADS)

    O'Brien, James G.; Moss, Robert J.

    2015-05-01

    Galactic rotation curves have proven to be the testing ground for dark matter bounds in galaxies, and our own Milky Way is one of many large spiral galaxies that must follow the same models. Over the last decade, the rotation of the Milky Way galaxy has been studied and extended by many authors. Since the work of conformal gravity has now successfully fit the rotation curves of almost 140 galaxies, we present here the fit to our own Milky Way. However, the Milky Way is not just an ordinary galaxy to append to our list, but instead provides a robust test of a fundamental difference of conformal gravity rotation curves versus standard cold dark matter models. It was shown by Mannheim and O'Brien that in conformal gravity, the presence of a quadratic potential causes the rotation curve to eventually fall off after its flat portion. This effect can currently be seen in only a select few galaxies whose rotation curve is studied well beyond a few multiples of the optical galactic scale length. Due to the recent work of Sofue et al and Kundu et al, the rotation curve of the Milky Way has now been studied to a degree where we can test the predicted fall off in the conformal gravity rotation curve. We find that - like the other galaxies already studied in conformal gravity - we obtain amazing agreement with rotational data and the prediction includes the eventual fall off at large distances from the galactic center.

  10. Factors affecting healing rates after arthroscopic double-row rotator cuff repair.

    PubMed

    Tashjian, Robert Z; Hollins, Anthony M; Kim, Hyun-Min; Teefey, Sharlene A; Middleton, William D; Steger-May, Karen; Galatz, Leesa M; Yamaguchi, Ken

    2010-12-01

    Double-row arthroscopic rotator cuff repairs were developed to improve initial biomechanical strength of repairs to improve healing rates. Despite biomechanical improvements, failure of healing remains a clinical problem. To evaluate the anatomical results after double-row arthroscopic rotator cuff repair with ultrasound to determine postoperative repair integrity and the effect of various factors on tendon healing. Case series; Level of evidence, 4. Forty-eight patients (49 shoulders) who had a complete arthroscopic rotator cuff repair (double-row technique) were evaluated with ultrasound at a minimum of 6 months after surgery. Outcome was evaluated at a minimum of 1-year follow-up with standardized history and physical examination, visual analog scale for pain, active forward elevation, and preoperative and postoperative shoulder scores according to the system of the American Shoulder and Elbow Surgeons and the Simple Shoulder Test. Quantitative strength was measured postoperatively. Ultrasound and physical examinations were performed at a minimum of 6 months after surgery (mean, 16 months; range, 6 to 36 months) and outcome questionnaire evaluations at a minimum of 12 months after surgery (mean, 29 months; range, 12 to 55 months). Of 49 repairs, 25 (51%) were healed. Healing rates were 67% in single-tendon tears (16 of 24 shoulders) and 36% in multitendon tears (9 of 25 shoulders). Older age and longer duration of follow-up were correlated with poorer tendon healing (P < .03). Visual analog scale for pain, active forward elevation, American Shoulder and Elbow Surgeons scores, and Simple Shoulder Test scores all had significant improvement from baseline after repair (P < .0001). Increased age and longer duration of follow-up were associated with lower healing rates after double-row rotator cuff repair. The biological limitation at the repair site, as reflected by the effects of age on healing, appears to be the most important factor influencing tendon healing, even after maximizing repair biomechanical strength with a double-row construct.

  11. Does crop rotational diversity increase soil microbial resistance and resilience to drought and flooding?

    NASA Astrophysics Data System (ADS)

    Schnecker, Jörg; Calderon, Francisco; Cavigelli, Michel; Lehman, Michael; Tiemann, Lisa; Grandy, Stuart

    2017-04-01

    Future climate scenarios indicate more frequent and stronger extreme weather events. This includes more severe droughts but also an increase in heavy rain events and flooding. Agricultural systems are of special interest in this context because of their role in food security but also because of their potentially changing role in global carbon and nutrient cycling under these extreme conditions. Plant diversification strategies like more complex crop rotations which support more diverse soil microbial communities with higher functional redundancy might be more resistant to drought and flooding and could help to reduce impacts on microbial carbon and nutrient cycling. To test how crop diversification affects the response of soil microbial processes to drought and flooding and reoccurring drought and flooding, we manipulated water regimes in lab incubation experiments using soils from four long term rotation experiments across the USA, including a low (one or two crops) vs. high (>3 crops) diversity rotations at each site. The sites range from low precipitation (Colorado), over intermediate precipitation (Michigan and South Dakota) to high precipitation in Maryland. Replicate sets of samples were either allowed to dry out, were gradually flooded or kept at a constant water content (control). We monitored CO2 production during five stress cycles. Additionally, we determined microbial biomass, enzyme activities and N pools during the first and last stress cycle in soils from the precipitation extremes. After a total incubation length of 165 days and five stress cycles only the soils from short rotations in Maryland and South Dakota that had been subjected to reoccurring drought showed significantly less cumulative CO2 loss compared to their respective controls. All the other sites and rotation length did not significantly differ from control when subjected to reoccurring drought or flooding. A Principal component analysis using all measured parameters of Colorado and Maryland soils showed a clear clustering of samples by site and in case of Maryland also by rotation length before the first stress. During the stress, samples were significantly separated by the treatment (drought and flooding). Immediately after the stress, samples again clustered by site and rotation length. After four stress cycles, soils from the long rotation in Colorado were the only samples that did not show a significant response to the laboratory treatments anymore. Our results indicate that agricultural soils, irrespective of the climatic region they are from and the rotation regime, are highly susceptible to changes in water content, especially drought. We did however also found that all tested soils were quickly recovering from the applied stress treatment and that plant diversification might help to increase the microbial resistance to water stress in certain soil systems.

  12. High pressure rotating reverse osmosis for long term space missions

    NASA Astrophysics Data System (ADS)

    Christensen Pederson, Cynthia Lynn

    Rotating reverse osmosis, which uses reverse osmosis to purify water and rotating filtration to improve the efficacy of filtration, has great potential for wastewater recycling on a long term space mission. Previous investigations of a proof-of-concept device indicated that the most efficient method to improve rotating reverse osmosis performance is to increase the operational pressure. Thus, a second generation device and fluid circuit were designed, fabricated, and tested to permit high pressure operation for long time periods. The design overcame several obstacles including membrane attachment, rotating seal design, and fluid and pressure management. A theoretical model of rotating reverse osmosis was modified to properly account for the flow conditions in the new design. Tests lasting a week were conducted with a variety of model wastewaters. Significant fouling and a decrease in flux were observed after three days of testing regardless of the operational parameters. A semi-empirical model, the fouling potential, was added to the theoretical model to account for the fouling. This allowed the simulation of 48 hour cleaning cycles that significantly increased the flux of the device. Experimental investigation of the rotational speed and concentrate flow rate indicated that an increase in either parameter decreased the fouling slightly. A week long test of a wastewater ersatz with a biocide did not exhibit a decrease in flux around day three that otherwise occurred. Therefore, biofouling was identified as the primary mechanism of fouling. Rotating reverse osmosis was compared with conventional spiral wound reverse osmosis and displayed increased rejection under dead end filtration conditions. The rotating device exhibited similar rejection and increased flux compared to a tubular reverse osmosis device previously used in a NASA wastewater recovery system. The integration of the rotating device into a NASA water recovery management system was evaluated. Lastly, a theoretical model of rotating hemofiltration was developed that demonstrated that the device is not clinically feasible given the permeability of available hemofiltration membranes.

  13. The Influence of Juggling on Mental Rotation Performance in Children

    ERIC Educational Resources Information Center

    Jansen, Petra; Lange, Leonie F.; Heil, Martin

    2011-01-01

    Study aim: To assess the influence of juggling training on mental rotation performance in children. Material and methods: Two groups of girls aged 6-14 years were studied: experimental (EG; n = 26) and control (CG; n = 24). All girls solved a mental rotation task with 3-D block figures on computer screen (pre-test). After the initial test, EG…

  14. Hypervelocity Impact Test Fragment Modeling: Modifications to the Fragment Rotation Analysis and Lightcurve Code

    NASA Technical Reports Server (NTRS)

    Gouge, Michael F.

    2011-01-01

    Hypervelocity impact tests on test satellites are performed by members of the orbital debris scientific community in order to understand and typify the on-orbit collision breakup process. By analysis of these test satellite fragments, the fragment size and mass distributions are derived and incorporated into various orbital debris models. These same fragments are currently being put to new use using emerging technologies. Digital models of these fragments are created using a laser scanner. A group of computer programs referred to as the Fragment Rotation Analysis and Lightcurve code uses these digital representations in a multitude of ways that describe, measure, and model on-orbit fragments and fragment behavior. The Dynamic Rotation subroutine generates all of the possible reflected intensities from a scanned fragment as if it were observed to rotate dynamically while in orbit about the Earth. This calls an additional subroutine that graphically displays the intensities and the resulting frequency of those intensities as a range of solar phase angles in a Probability Density Function plot. This document reports the additions and modifications to the subset of the Fragment Rotation Analysis and Lightcurve concerned with the Dynamic Rotation and Probability Density Function plotting subroutines.

  15. Advances in measuring techniques for turbine cooling test rigs - Status report

    NASA Technical Reports Server (NTRS)

    Pollack, F. G.

    1974-01-01

    Instrumentation development pertaining to turbine cooling research has resulted in the design and testing of several new systems. Pressure measurements on rotating components are being made with a rotating system incorporating ten miniature transducers and a slip-ring assembly. The system has been tested successfully up to speeds of 9000 rpm. An advanced system development combining pressure transducer and thermocouple signals is also underway. Thermocouple measurements on rotating components are transferred off the shaft by a 72-channel rotating data system. Thermocouple data channels are electronically processed on board and then removed from the shaft in the form of a digital serial train by one winding of a rotary transformer.

  16. Validity of eyeball estimation for range of motion during the cervical flexion rotation test compared to an ultrasound-based movement analysis system.

    PubMed

    Schäfer, Axel; Lüdtke, Kerstin; Breuel, Franziska; Gerloff, Nikolas; Knust, Maren; Kollitsch, Christian; Laukart, Alex; Matej, Laura; Müller, Antje; Schöttker-Königer, Thomas; Hall, Toby

    2018-08-01

    Headache is a common and costly health problem. Although pathogenesis of headache is heterogeneous, one reported contributing factor is dysfunction of the upper cervical spine. The flexion rotation test (FRT) is a commonly used diagnostic test to detect upper cervical movement impairment. The aim of this cross-sectional study was to investigate concurrent validity of detecting high cervical ROM impairment during the FRT by comparing measurements established by an ultrasound-based system (gold standard) with eyeball estimation. Secondary aim was to investigate intra-rater reliability of FRT ROM eyeball estimation. The examiner (6 years experience) was blinded to the data from the ultrasound-based device and to the symptoms of the patients. FRT test result (positive or negative) was based on visual estimation of range of rotation less than 34° to either side. Concurrently, range of rotation was evaluated using the ultrasound-based device. A total of 43 subjects with headache (79% female), mean age of 35.05 years (SD 13.26) were included. According to the International Headache Society Classification 23 subjects had migraine, 4 tension type headache, and 16 multiple headache forms. Sensitivity and specificity were 0.96 and 0.89 for combined rotation, indicating good concurrent reliability. The area under the ROC curve was 0.95 (95% CI 0.91-0.98) for rotation to both sides. Intra-rater reliability for eyeball estimation was excellent with Fleiss Kappa 0.79 for right rotation and left rotation. The results of this study indicate that the FRT is a valid and reliable test to detect impairment of upper cervical ROM in patients with headache.

  17. Deficiency in Mental Rotation of Upper and Lower-Limbs in Patients With Multiple Sclerosis and Its Relation With Cognitive Functions.

    PubMed

    Azin, Mahdieh; Zangiabadi, Nasser; Moghadas Tabrizi, Yousef; Iranmanesh, Farhad; Baneshi, Mohammad Reza

    2016-08-01

    Mental rotation is a cognitive motor process which was impaired in different neurologic disorders. We investigated whether there were deficits in response pattern, reaction time and response accuracy rate of mental rotation in multiple sclerosis (MS) patients compared to healthy subjects and whether cognitive dysfunctions in MS patients were correlated with mental rotation deficits. Moreover, we showed whether there was a difference between upper and lower-limbs mental rotation in MS patients. Thirty-five MS patients and 25 healthy subjects performed hand mental rotation (HMR) and foot mental rotation (FMR) tasks. Visual information processing speed, spatial learning and memory ability, and visuospatial processing were assessed by Symbol Digit Modalities Test (SDMT), Brief Visuospatial Memory Test-Revised (BVMT-R), and Judgment of Line Orientation Test (JLO) respectively in MS patients. Reaction time for both hand and foot stimuli increased, and response accuracy rate for hand stimuli decreased in MS patients compared to healthy subjects, but response pattern of mental rotation in MS patients persisted. Similar to healthy subjects, MS patients performed upper-limbs mental rotation more easily than a lower-limbs mental rotation with more speed and response accuracy rate. Reaction time and response accuracy rate were correlated with the mentioned cognitive functions. MS patients made use of the correct response pattern for problem solving of increasing orientation from upright stimuli. Reaction time and response accuracy rate altered in these patients and this alteration might occur along with impairment in motor planning. Subjects' better responding to hand stimuli was due to more familiarity with hand stimuli. The correlation of mental rotation ability with cognitive functions indicates the possible role of cognitive functions in mental rotation.

  18. The Nature of Relationships between Mental Rotation, Math, and Language in Deaf Signers

    ERIC Educational Resources Information Center

    Halper, Elizabeth Blaisdell

    2009-01-01

    Three mental rotation tasks, the Card Rotation Task (CRT), the Vandenberg Mental Rotation Test (VMRT), and the Money Road-Map of Direction Sense (MRM), were administered to 60 deaf students from Gallaudet University to determine if mental rotation was predictive of scores on the ACT English or Math subtests. Other predictor variables, such as…

  19. [Impacts of rotating or lifting-thrusting manipulation on distant vision of naked eye in patients of juvenile myopia: a randomized controlled trial].

    PubMed

    Tao, Xiao-Yan; Zhao, Bai-Yiao; Han, Xiao; Dong, Xiao-Yu; Yan, An; Ren, Xu-Ru; Liu, Yan-Wen; Qu, Chang; Xia, Shu-Fen; Yang, Jia-Le

    2014-05-01

    To compare the differences in the efficacy on distant version of naked eye in the patients of juvenile myopia between rotating manipulation and lifting-thrusting manipulation of acupuncture. One hundred and twenty cases (240 eyes) were randomized into a rotating manipulation group and a lifting-thrusting manipulation group, 60 cases (120 eyes) in each group. Additionally, a corrective lenses group, 60 cases (120 eyes), was set up as the control. In both manipulation groups, Cuanzhu (BL 2),Yuyao (EX-HN 4), Sizhukong (TE 23), Taiyang (EX-HN 5), Fengchi (GB 20), Zusanli (ST 36), Guangming (GB 37) and Sanyinjiao (SP 6) were punctured, but stimulated with rotating manipulation and lifting-thrusting manipulation respectively three times per week, 10 times as a treatment session and totally one session was required. In the corrective lenses group, the glasses were applied at daytime. The clinical efficacy and the changes in distant vision of naked eye before and after treatment were compared among the three groups. The total effective rate was 87.5% (105/120) in the rotating manipulation group, which was better than 69.2% (83/120) in the lifting-thrusting manipulation group (P < 0.05). The distant vision of naked eye was improved apparently in the rotating manipulation group and the lifting-thrusting manipulation group after treatment (both P < 0.05). But it was not improved in the corrective lenses group (P > 0.05). The distant vision of naked eye was improved more apparently after treatment in the rotating manipulation group as compared with that in the lifting-thrusting manipulation group (0.75 +/- 0.23 vs 0.68 +/- 0.24, P < 0.05). For 96 cases (192 eyes) with acupuncture treatment, in 3-month follow-up, 87.0% (167/192) of the cases maintained the stable vision as the original level and 13.0% (25/192) of them were reduced in the vision In the acupuncture groups, it was found that the improvement of distant vision of naked eye was more obvious after treatment with younger age, better basic vision and shorter duration of sickness (all P < 0.05). Acupuncture achieves the positive and sustainable clinical effect on juvenile myopia, and the results of rotating manipulation are superior to that of lifting-thrusting manipulation. Age, basic vision and duration of sickness impact the clinical efficacy.

  20. Tidal resonances in binary star systems. II - Slowly rotating stars

    NASA Astrophysics Data System (ADS)

    Alexander, M. E.

    1988-12-01

    The potential energy of tidal interactions in a binary system with rotating components is formulated as a perturbation Hamiltonian which self-consistently couples the dynamics of the rotating stars' oscillations and orbital motion. The action-angle formalism used to discuss tidal resonances in the nonrotating case (Alexander, 1987) is extended to rotating stars. The behavior of a two-mode system and the procedure for treating an arbitrary number of modes are discussed.

  1. Reverse intestinal rotation: a rare case of volvulus around a vitelline duct remnant

    PubMed Central

    Dreyer, Stephan; Kaczynski, Jakub; Hrobar, Petr; Collins, Patrick

    2014-01-01

    We present a rare case of reverse intestinal rotation with volvulus around a Meckel's diverticulum attached to a vitelline duct remnant. The diagnosis was established by CT. The patient was treated with exploratory laparotomy and small bowel resection. The patient made a full recovery and was discharged home on the seventh postoperative day. PMID:25246458

  2. Twist effects in quantum vortices and phase defects

    NASA Astrophysics Data System (ADS)

    Zuccher, Simone; Ricca, Renzo L.

    2018-02-01

    In this paper we show that twist, defined in terms of rotation of the phase associated with quantum vortices and other physical defects effectively deprived of internal structure, is a property that has observable effects in terms of induced axial flow. For this we consider quantum vortices governed by the Gross-Pitaevskii equation (GPE) and perform a number of test cases to investigate and compare the effects of twist in two different contexts: (i) when this is artificially superimposed on an initially untwisted vortex ring; (ii) when it is naturally produced on the ring by the simultaneous presence of a central straight vortex. In the first case large amplitude perturbations quickly develop, generated by the unnatural setting of the initial condition that is not an analytical solution of the GPE. In the second case much milder perturbations emerge, signature of a genuine physical process. This scenario is confirmed by other test cases performed at higher twist values. Since the second setting corresponds to essential linking, these results provide new evidence of the influence of topology on physics.

  3. Embedding patient simulation in a pediatric cardiology rotation: a unique opportunity for improving resident education.

    PubMed

    Mohan, Shaun; Follansbee, Christopher; Nwankwo, Ugonna; Hofkosh, Dena; Sherman, Frederick S; Hamilton, Melinda F

    2015-01-01

    High-fidelity patient simulation (HFPS) has been used in medical education to bridge gaps in medical knowledge and clinical skills. Few studies have analyzed the impact of HFPS in subspecialty rotations for pediatric residents. We hypothesized that pediatric residents exposed to HFPS with a structured content curriculum would perform better on a case quiz than residents without exposure to HFPS. Prospective randomized controlled Tertiary-care free standing children's hospital During a cardiology rotation, senior pediatric residents completed an online pediatric cardiology curriculum and a cardiology quiz. After randomization into two groups, the study group participated in a fully debriefed HFPS session. The control group had no HFPS. Both groups completed a case quiz. Confidence surveys pre- and postsimulation were completed. From October 2010 through March 2013, 55 residents who rotated through the pediatric cardiology rotation were used in the final analysis (30 control, 25 in the study group). There was no significant difference between groups on the initial cardiology quiz. The study group scored higher on the case quiz compared with the control group (P = .024). Based on pre- and postsimulation questionnaires, residents' confidence in approaching a pediatric cardiology patient improved from an average Likert score of 5.1 to 7.5 (on scale of 0-10) (P < .001). Incorporation of HFPS into a preexisting pediatric cardiology rotation was feasible and well received. Our study suggests that simulation promotes increased confidence and may modestly improve clinical reasoning compared to traditional educational techniques. Targeted simulation sessions may readily be incorporated into pediatric subspecialty rotations. © 2014 Wiley Periodicals, Inc.

  4. Time-varying Entry Heating Profile Replication with a Rotating Arc Jet Test Article

    NASA Technical Reports Server (NTRS)

    Grinstead, Jay Henderson; Venkatapathy, Ethiraj; Noyes, Eric A.; Mach, Jeffrey J.; Empey, Daniel M.; White, Todd R.

    2014-01-01

    A new approach for arc jet testing of thermal protection materials at conditions approximating the time-varying conditions of atmospheric entry was developed and demonstrated. The approach relies upon the spatial variation of heat flux and pressure over a cylindrical test model. By slowly rotating a cylindrical arc jet test model during exposure to an arc jet stream, each point on the test model will experience constantly changing applied heat flux. The predicted temporal profile of heat flux at a point on a vehicle can be replicated by rotating the cylinder at a prescribed speed and direction. An electromechanical test model mechanism was designed, built, and operated during an arc jet test to demonstrate the technique.

  5. The effect of the long head of the biceps on glenohumeral kinematics.

    PubMed

    Youm, Thomas; ElAttrache, Neal S; Tibone, James E; McGarry, Michelle H; Lee, Thay Q

    2009-01-01

    The long head of the biceps has been described as a stabilizing force in the setting of glenohumeral instability. However, data are lacking on the effect of loading the long head of the biceps on glenohumeral kinematics. Six cadaveric shoulders were tested for glenohumeral rotational range of motion and translation using a custom shoulder testing system and the Microscribe 3DLX (Immersion, San Jose, CA). The path of glenohumeral articulation (PGA) was measured by calculating the humeral head center with respect to the glenoid articular surface at maximal internal rotation, 30 degrees, 60 degrees, 90 degrees, and maximal external rotation. Significant decreases in glenohumeral rotational range of motion and translation were found with 22-N biceps loading vs the unloaded group. With respect to the PGA, the humeral rotation center was shifted posterior with biceps loading at maximal internal rotation, 30 degrees, and 60 degrees of external rotation. Loading the long head of the biceps significantly affects glenohumeral rotational range of motion, translations, and kinematics.

  6. Review of the Usefulness of Various Rotational Seismometers with Laboratory Results of Fibre-Optic Ones Tested for Engineering Applications

    PubMed Central

    Jaroszewicz, Leszek R.; Kurzych, Anna; Krajewski, Zbigniew; Marć, Paweł; Kowalski, Jerzy K.; Bobra, Piotr; Zembaty, Zbigniew; Sakowicz, Bartosz; Jankowski, Robert

    2016-01-01

    Starting with descriptions of rotational seismology, areas of interest and historical field measurements, the fundamental requirements for rotational seismometers for seismological and engineering application are formulated. On the above basis, a review of all existing rotational seismometers is presented with a description of the principles of their operation as well as possibilities to fulfill formulated requirements. This review includes mechanical, acoustical, electrochemical and optical devices and shows that the last of these types are the most promising. It is shown that optical rotational seismometer based on the ring-laser gyroscope concept is the best for seismological applications, whereas systems based on fiber-optic gyroscopes demonstrate parameters which are also required for engineering applications. Laboratory results of the Fibre-Optic System for Rotational Events & Phenomena Monitoring using a small 1-D shaking table modified to generate rotational excitations are presented. The harmonic and time-history tests demonstrate its usefulness for recording rotational motions with rates up to 0.25 rad/s. PMID:27999299

  7. The experimental behavior of spinning pretwisted laminated composite plates

    NASA Technical Reports Server (NTRS)

    Kosmatka, John B.; Lapid, Alex J.

    1993-01-01

    The purpose of the research is to gain an understanding of the material and geometric couplings present in advanced composite turbo-propellers. Twelve pre-twisted laminated composite plates are tested. Three different ply lay-ups (2 symmetric and 1 asymmetric) and four different geometries (flat and 30x pre-twist about the mid-chord, quarter-chord, and leading edge) distinguish each plate from one another. Four rotating and non-rotating tests are employed to isolate the material and geometric couplings of an advanced turbo propeller. The first series of tests consist of non-rotating static displacement, strain, and vibrations. These tests examine the effects of ply lay-up and geometry. The second series of tests consist of rotating displacement, strain, and vibrations with various pitch and sweep settings. These tests utilize the Dynamic Spin Rig Facility at the NASA Lewis Research Center. The rig allows the spin testing of the plates in a near vacuum environment. The tests examine how the material and plate geometry interact with the pitch and sweep geometry of an advanced turbo-propeller.

  8. Using flow information to support 3D vessel reconstruction from rotational angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Waechter, Irina; Bredno, Joerg; Weese, Juergen

    2008-07-15

    For the assessment of cerebrovascular diseases, it is beneficial to obtain three-dimensional (3D) morphologic and hemodynamic information about the vessel system. Rotational angiography is routinely used to image the 3D vascular geometry and we have shown previously that rotational subtraction angiography has the potential to also give quantitative information about blood flow. Flow information can be determined when the angiographic sequence shows inflow and possibly outflow of contrast agent. However, a standard volume reconstruction assumes that the vessel tree is uniformly filled with contrast agent during the whole acquisition. If this is not the case, the reconstruction exhibits artifacts. Here,more » we show how flow information can be used to support the reconstruction of the 3D vessel centerline and radii in this case. Our method uses the fast marching algorithm to determine the order in which voxels are analyzed. For every voxel, the rotational time intensity curve (R-TIC) is determined from the image intensities at the projection points of the current voxel. Next, the bolus arrival time of the contrast agent at the voxel is estimated from the R-TIC. Then, a measure of the intensity and duration of the enhancement is determined, from which a speed value is calculated that steers the propagation of the fast marching algorithm. The results of the fast marching algorithm are used to determine the 3D centerline by backtracking. The 3D radius is reconstructed from 2D radius estimates on the projection images. The proposed method was tested on computer simulated rotational angiography sequences with systematically varied x-ray acquisition, blood flow, and contrast agent injection parameters and on datasets from an experimental setup using an anthropomorphic cerebrovascular phantom. For the computer simulation, the mean absolute error of the 3D centerline and 3D radius estimation was 0.42 and 0.25 mm, respectively. For the experimental datasets, the mean absolute error of the 3D centerline was 0.45 mm. Under pulsatile and nonpulsatile conditions, flow information can be used to enable a 3D vessel reconstruction from rotational angiography with inflow and possibly outflow of contrast agent. We found that the most important parameter for the quality of the reconstruction of centerline and radii is the range through which the x-ray system rotates in the time span of the injection. Good results were obtained if this range was at least 135 deg. . As a standard c-arm can rotate 205 deg., typically one third of the acquisition can show inflow or outflow of contrast agent, which is required for the quantification of blood flow from rotational angiography.« less

  9. Optical EVPA rotations in blazars: testing a stochastic variability model with RoboPol data

    NASA Astrophysics Data System (ADS)

    Kiehlmann, S.; Blinov, D.; Pearson, T. J.; Liodakis, I.

    2017-12-01

    We identify rotations of the polarization angle in a sample of blazars observed for three seasons with the RoboPol instrument. A simplistic stochastic variability model is tested against this sample of rotation events. The model is capable of producing samples of rotations with parameters similar to the observed ones, but fails to reproduce the polarization fraction at the same time. Even though we can neither accept nor conclusively reject the model, we point out various aspects of the observations that are fully consistent with a random walk process.

  10. An assumed-stress hybrid 4-node shell element with drilling degrees of freedom

    NASA Technical Reports Server (NTRS)

    Aminpour, M. A.

    1992-01-01

    An assumed-stress hybrid/mixed 4-node quadrilateral shell element is introduced that alleviates most of the deficiencies associated with such elements. The formulation of the element is based on the assumed-stress hybrid/mixed method using the Hellinger-Reissner variational principle. The membrane part of the element has 12 degrees of freedom including rotational or 'drilling' degrees of freedom at the nodes. The bending part of the element also has 12 degrees of freedom. The bending part of the element uses the Reissner-Mindlin plate theory which takes into account the transverse shear contributions. The element formulation is derived from an 8-node isoparametric element by expressing the midside displacement degrees of freedom in terms of displacement and rotational degrees of freedom at corner nodes. The element passes the patch test, is nearly insensitive to mesh distortion, does not 'lock', possesses the desirable invariance properties, has no hidden spurious modes, and for the majority of test cases used in this paper produces more accurate results than the other elements employed herein for comparison.

  11. Needle puncture in rabbit functional spinal units alters rotational biomechanics.

    PubMed

    Hartman, Robert A; Bell, Kevin M; Quan, Bichun; Nuzhao, Yao; Sowa, Gwendolyn A; Kang, James D

    2015-04-01

    An in vitro biomechanical study for rabbit lumbar functional spinal units (FSUs) using a robot-based spine testing system. To elucidate the effect of annular puncture with a 16 G needle on mechanical properties in flexion/extension, axial rotation, and lateral bending. Needle puncture of the intervertebral disk has been shown to alter mechanical properties of the disk in compression, torsion, and bending. The effect of needle puncture in FSUs, where intact spinal ligaments and facet joints may mitigate or amplify these changes in the disk, on spinal motion segment stability subject to physiological rotations remains unknown. Rabbit FSUs were tested using a robot testing system whose force/moment and position precision were assessed to demonstrate system capability. Flexibility testing methods were developed by load-to-failure testing in flexion/extension, axial rotation, and lateral bending. Subsequent testing methods were used to examine a 16 G needle disk puncture and No. 11 blade disk stab (positive control for mechanical disruption). Flexibility testing was used to assess segmental range-of-motion (degrees), neutral zone stiffness (N m/degrees) and width (degrees and N m), and elastic zone stiffness before and after annular injury. The robot-based system was capable of performing flexibility testing on FSUs-mean precision of force/moment measurements and robot system movements were <3% and 1%, respectively, of moment-rotation target values. Flexibility moment targets were 0.3 N m for flexion and axial rotation and 0.15 N m for extension and lateral bending. Needle puncture caused significant (P<0.05) changes only in flexion/extension range-of-motion and neutral zone stiffness and width (N m) compared with preintervention. No. 11 blade-stab significantly increased range-of-motion in all motions, decreased neutral zone stiffness and width (N m) in flexion/extension, and increased elastic zone stiffness in flexion and lateral bending. These findings suggest that disk puncture and stab can destabilize FSUs in primary rotations.

  12. Rotator cuff repair healing influenced by platelet-rich plasma construct augmentation.

    PubMed

    Barber, F Alan; Hrnack, Scott A; Snyder, Stephen J; Hapa, Onur

    2011-08-01

    To assess the effect of platelet-rich plasma fibrin matrix (PRPFM) construct augmentation on postoperative tendon healing as determined by magnetic resonance imaging (MRI) and clinical outcome of arthroscopic rotator cuff repair. A comparative series of patients undergoing arthroscopic rotator cuff repair was studied. Two matched groups of patients (20 each) were included: rotator cuff repairs without PRPFM augmentation (group 1) and rotator cuff repairs augmented with 2 sutured platelet-rich plasma (PRP) constructs (group 2). A single-row cuff repair to the normal footprint without tension or marrow vents was performed by a single surgeon. Postoperative rehabilitation was held constant. Postoperative MRI scans were used to evaluate rotator cuff healing. Outcome measures included American Shoulder and Elbow Surgeons, Rowe, Single Assessment Numeric Evaluation, Simple Shoulder Test, and Constant scores. We followed up 40 patients (2 matched groups with 20 patients each) with a mean age of 57 years (range, 44 to 69 years) for a mean of 31 months (range, 24 to 44 months). Postoperative MRI studies showed persistent full-thickness tendon defects in 60% of controls (12 of 20) and 30% of PRPFM-augmented repairs (6 of 20) (P = .03). Of the control group tears measuring less than 3 cm in anteroposterior length, 50% (7 of 14) healed fully, whereas 86% of the PRPFM group tears measuring less than 3 cm in anteroposterior length (12 of 14) healed fully (P < .05). There was no significant difference between groups 1 and 2 in terms of American Shoulder and Elbow Surgeons (94.7 and 95.7, respectively; P = .35), Single Assessment Numeric Evaluation (93.7 and 94.5, respectively; P = .37), Simple Shoulder Test (11.4 and 11.3, respectively; P = .41), and Constant (84.7 and 88.1, respectively; P = .19) scores. The Rowe scores (84.8 and 94.9, respectively; P = .03) were statistically different. The addition of 2 PRPFM constructs sutured into a primary rotator cuff tendon repair resulted in lower retear rates identified on MRI than repairs without the constructs. Other than the Rowe scores, there was no postoperative clinical difference by use of standard outcome measures. Level III, case-control study. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Anatomical knowledge retention in third-year medical students prior to obstetrics and gynecology and surgery rotations.

    PubMed

    Jurjus, Rosalyn A; Lee, Juliet; Ahle, Samantha; Brown, Kirsten M; Butera, Gisela; Goldman, Ellen F; Krapf, Jill M

    2014-01-01

    Surgical anatomy is taught early in medical school training. The literature shows that many physicians, especially surgical specialists, think that anatomical knowledge of medical students is inadequate and nesting of anatomical sciences later in the clinical curriculum may be necessary. Quantitative data concerning this perception of an anatomical knowledge deficit are lacking, as are specifics as to what content should be reinforced. This study identifies baseline areas of strength and weakness in the surgical anatomy knowledge of medical students entering surgical rotations. Third-year medical students completed a 20-25-question test at the beginning of the General Surgery and Obstetrics and Gynecology rotations. Knowledge of inguinal anatomy (45.3%), orientation in abdominal cavity (38.8%), colon (27.7%), and esophageal varices (12.8%) was poor. The numbers in parentheses are the percentage of questions answered correctly per topic. In comparing those scores to matched test items from this cohort as first-year students in the anatomy course, the drop in retention overall was very significant (P = 0.009) from 86.9 to 51.5%. Students also scored lower in questions relating to pelvic organs (46.7%), urogenital development (54.0%), pulmonary development (17.8%), and pregnancy (17.8%). These data showed that indeed, knowledge of surgical anatomy is poor for medical students entering surgical clerkships. These data collected will be utilized to create interactive learning modules, aimed at improving clinically relevant anatomical knowledge retention. These modules, which will be available to students during their inpatient surgical rotations, connect basic anatomy principles to clinical cases, with the ultimate goal of closing the anatomical knowledge gap. © 2014 American Association of Anatomists.

  14. Relationship between femoroacetabular contact areas and hip position in the normal joint: an in vitro evaluation.

    PubMed

    Signorelli, Cecilia; Lopomo, Nicola; Bonanzinga, Tommaso; Marcheggiani Muccioli, Giulio Maria; Safran, Marc R; Marcacci, Maurilio; Zaffagnini, Stefano

    2013-02-01

    Different approaches have been proposed to diagnose femoroacetabular impingement (FAI) condition and hip instability. It is still debatable which test is the most effective to make a correct diagnosis. The true mechanics of the hip during particular physical examination manoeuvres is unknown. Eight fresh frozen hips were passively taken through 3 different commonly used positions for FAI diagnosis and hip instability: 90° Flexion-Adduction-Internal Rotation, Hyperextension-Adduction-External Rotation and Hyperextension-Neutral-External Rotation. Kinematics and anatomical data were acquired by an optoelectronic system. The contact areas between acetabulum and femoral head were analysed to determine whether these tests are able to localize regions of the hip that may give patients pain. In the hip positions where the femur was in Hyperextension-External Rotation, the contact area was mainly concentrated in the posterosuperior area of the acetabulum, while during 90° Flexion-Adduction-Internal Rotation position, there was a wider distribution of contact, not specific to the anterolateral acetabulum. The results confirm the ability of the Hyperextension-External Rotation tests to particularly analyse the posterior region of the acetabulum. Placing the hip in 90° of Flexion-Adduction-Internal Rotation allows for testing a wider zone of the acetabulum and is not specific to abutment of the femoral head-neck region against the anterolateral acetabulum.

  15. Artificial atlanto-odontoid joint replacement through a transoral approach.

    PubMed

    Lu, Bin; He, Xi Jing; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong

    2009-01-01

    Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1-C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P B 0.021) and NZ (P B 0.002) and a significantly increased stiffness (P \\ 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P C 0.719), NZ (P C 0.580), and stiffness (P C 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test. This artificial atlanto-odontoid joint may be useful in cases of odontoid resection due to malunion or nonunion of odontoid fracture, atraumatic odontoid fracture, irreducible atlas dislocation, posterior atlantoaxial subluxation, or congenital skull base abnormalities.

  16. Artificial atlanto-odontoid joint replacement through a transoral approach

    PubMed Central

    Lu, Bin; Zhao, Chen Guang; Li, Hao Peng; Wang, Dong

    2008-01-01

    Resection of the odontoid process and anterior arch of the atlas results in atlantoaxial instability, which if left uncorrected may lead to severe neurological complications. Currently, such atlantoaxial instability is corrected by anterior and/or posterior C1–C2 fusion. However, this results in considerable loss of rotation function of the atlantoaxial complex. From the viewpoint of retaining the rotation function and providing stability, we designed an artificial atlanto-odontoid joint based on anatomical measurements of 50 pairs of dry atlantoaxial specimens by digital calipers and 10 fresh cadaveric specimens by microsurgical techniques. The metal-on-metal titanium alloy joint has an arc-shaped atlas component, and a hollow cylindrical bushing into which fits a rotation axle of an inverted v-shaped axis component and is implanted through a transoral approach. After the joint was implanted onto specimens with anterior decompression, biomechanical tests were performed to compare the stability parameters in the intact state, after decompression, after artificial joint replacement, and after fatigue test. Compared to the intact state, artificial joint replacement resulted in a significant decrease in the range of motion (ROM) and neutral zone (NZ) during flexion, extension, and lateral bending (P < 0.001); however, with regard to axial rotation, there was no significant difference in ROM (P = 0.405), a significant increase in NZ (P = 0.008), and a significant decrease in stiffness (P = 0.003). Compared to the decompressed state, artificial joint replacement resulted in a significantly decreased ROM (P ≤ 0.021) and NZ (P ≤ 0.002) and a significantly increased stiffness (P < 0.001) in all directions. Following artificial joint replacement, there was no significant difference in ROM (P ≥ 0.719), NZ (P ≥ 0.580), and stiffness (P ≥ 0.602) in all directions before and after the fatigue test. The artificial joint showed no signs of wear and tear after the fatigue test. This artificial atlanto-odontoid joint may be useful in cases of odontoid resection due to malunion or nonunion of odontoid fracture, atraumatic odontoid fracture, irreducible atlas dislocation, posterior atlantoaxial subluxation, or congenital skull base abnormalities. PMID:19043745

  17. [Benefit of rotational exercises for patients with Meniere's syndrome, method used by the ENT department of St-Luc university clinic].

    PubMed

    Nyabenda, A; Briart, C; Deggouj, N; Gersdorff, M

    2003-12-01

    To date, the effectiveness of balanced rehabilitation for patients with Meniere's syndrome has not been unanimously acknowledged by all physicians and physiotherapists. The purpose of this study is to assess the therapeutic efficacy of rotational exercises in the treatment of disequilibrium for patients with unilateral Meniere's syndrome. Rotational stimuli were used to symmetrize and reduce postrotatory nystagmic response. Three reference sources were used to assess the efficacy of this management: vestibulospinal function tests: pre- and post-treatment results at the Romberg test, the Unterberger-Fukuda stepping test, the Babinski-Weil test, and gait testing with eyes closed; rotational tests: pre- and post-treatment results; and the self-perceived impact of vertigo: assessed by the Dizziness Handicap Inventory (DHI) and a scale based on the guidelines of the Japanese Society of Equilibrium Research (JSER, 1993). The JSER scale provides quantitative vertigo evaluation; the DHI reflects the patient's perceptual evaluation of handicap. Patients required 11 sessions (mean value) to attain subjective improvement. Of the 23 patients, only seven required optokinetic stimulation (mean requirement: three sessions). Rotational tests and dynamic tests of the vestibulospinal function improved. The DHI and JSER results show that patients' post-rehabilitation perceptual evaluation significantly improved. The objective and subjective measures of disequilibrium in patients with unilateral Meniere's syndrome were significantly improved.

  18. THE NEXT GENERATION VIRGO CLUSTER SURVEY XVI: THE ANGULAR MOMENTUM OF DWARF EARLY-TYPE GALAXIES FROM GLOBULAR CLUSTER SATELLITES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toloba, Elisa; Guhathakurta, Puragra; Li, Biao

    2016-05-01

    We analyze the kinematics of six Virgo cluster dwarf early-type galaxies (dEs) from their globular cluster (GC) systems. We present new Keck/DEIMOS spectroscopy for three of them and re-analyze the data found in the literature for the remaining three. We use two independent methods to estimate the rotation amplitude ( V {sub rot}) and velocity dispersion ( σ {sub GC}) of the GC systems and evaluate their statistical significance by simulating non-rotating GC systems with the same number of GC satellites and velocity uncertainties. Our measured kinematics agree with the published values for the three galaxies from the literature and,more » in all cases, some rotation is measured. However, our simulations show that the null hypothesis of being non-rotating GC systems cannot be ruled out. In the case of VCC 1861, the measured V {sub rot} and the simulations indicate that it is not rotating. In the case of VCC 1528, the null hypothesis can be marginally ruled out, and thus it might be rotating although further confirmation is needed. In our analysis, we find that, in general, the measured V {sub rot} tends to be overestimated and the measured σ {sub GC} tends to be underestimated by amounts that depend on the intrinsic V {sub rot}/ σ {sub GC}, the number of observed GCs ( N {sub GC}), and the velocity uncertainties. The bias is negligible when N {sub GC} ≳ 20. In those cases where a large N {sub GC} is not available, it is imperative to obtain data with small velocity uncertainties. For instance, errors of ≤2 km s{sup −1} lead to V {sub rot} < 10 km s{sup −1} for a system that is intrinsically not rotating.« less

  19. Medialized repair for retracted rotator cuff tears.

    PubMed

    Kim, Young-Kyu; Jung, Kyu-Hak; Won, Jun-Sung; Cho, Seung-Hyun

    2017-08-01

    The purpose of this study was to evaluate the functional outcomes of medialized rotator cuff repair and the continuity of repaired tendon in chronic retracted rotator cuff tears. Thirty-five consecutive patients were selected from 153 cases that underwent arthroscopic rotator cuff repair for more than medium-sized posterosuperior rotator cuff tears between July 2009 and July 2012 performed with the medialized repair. All cases were available for at least 2 years of postoperative follow-up. The visual analog scale of pain, muscle strength, Constant score, American Shoulder and Elbow Surgeons (ASES) score, and University of California-Los Angeles score were evaluated. At the final follow-up, all clinical outcomes were significantly improved. The visual analog scale score for pain improved from 6 ± 1 preoperatively to 2 ± 1 postoperatively. The range of motion increased from preoperatively to postoperatively: active forward elevation, from 134° ± 49° to 150° ± 16°; active external rotation at the side, from 47° ± 15° to 55° ± 10°; and active internal rotation, from L3 to L1. The shoulder score also improved: Constant score, from 53.5 ± 16.7 to 79 ± 10; American Shoulder and Elbow Surgeons score, from 51 ± 15 to 82 ± 8; and University of California-Los Angeles score, from 14 ± 4 to 28 ± 4. The retear cases at the final follow-up were 6 (17%). Medialized repair may be useful in cases in which anatomic bone-to-tendon repair would be difficult because of the excessive tension of the repaired tendon and a torn tendon that does not reach the anatomic insertion. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. C2 spondylotic radiculopathy: the nerve root impingement mechanism investigated by para-sagittal CT/MRI, dynamic rotational CT, intraoperative microscopic findings, and treated by microscopic posterior foraminotomy.

    PubMed

    Fujiwara, Yasushi; Izumi, Bunichiro; Fujiwara, Masami; Nakanishi, Kazuyoshi; Tanaka, Nobuhiro; Adachi, Nobuo; Manabe, Hideki

    2017-04-01

    C2 radiculopathy is known to cause occipito-cervical pain, but their pathology is unclear because of its rarity and unique anatomy. In this paper, we investigated the mechanism of C2 radiculopathy that underwent microscopic cervical foraminotomies (MCF). Three cases with C2 radiculopathy treated by MCF were investigated retrospectively. The mean follow-up period was 24 months. Pre-operative symptoms, imaging studies including para-sagittal CT and MRI, rotational dynamic CT, and intraoperative findings were investigated. There were 1 male and 2 females. The age of patients were ranged from 50 to 79 years. All cases had intractable occipito-cervical pain elicited by the cervical rotation. C2 nerve root block was temporally effective. There was unilateral spondylosis in symptomatic side without obvious atlatoaxial instability. Para-sagittal MRI and CT showed severe foraminal stenosis at C1-C2 due to the bony spur derived from the lateral atlanto-axial joints. In one case, dynamic rotational CT showed that the symptomatic foramen became narrower on rotational position. MCF was performed in all cases, and the C2 nerve root was impinged between the inferior edge of the C1 posterior arch and bony spur from the C1-C2 joint. After surgery, occipito-cervical pain disappeared. This study demonstrated that mechanical impingement of the C2 nerve root is one of the causes of occipito-cervical pain and it was successfully treated by microscopic resection of the inferior edge of the C1 posterior arch. Para-sagittal CT and MRI, rotational dynamic CT, and nerve root block were effective for diagnosis.

  1. Computer program for determining rotational line intensity factors for diatomic molecules

    NASA Technical Reports Server (NTRS)

    Whiting, E. E.

    1973-01-01

    A FORTRAN IV computer program, that provides a new research tool for determining reliable rotational line intensity factors (also known as Honl-London factors), for most electric and magnetic dipole allowed diatomic transitions, is described in detail. This users manual includes instructions for preparing the input data, a program listing, detailed flow charts, and three sample cases. The program is applicable to spin-allowed dipole transitions with either or both states intermediate between Hund's case (a) and Hund's case (b) coupling and to spin-forbidden dipole transitions with either or both states intermediate between Hund's case (c) and Hund's case (b) coupling.

  2. SU-G-TeP4-15: The Roucoulette: A Set of Quality Control Tests for Dynamic Trajectory (4Pi) Treatment Delivery Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teke, T

    Purpose: To present and validate a set of quality control tests for trajectory treatment delivery using synchronized dynamic couch (translation and rotation), MLC and collimator motion. Methods: The quality control tests are based on the Picket fence test, which consist of 5 narrow band 2mm width spaced at 2.5cm intervals, and adds progressively synchronized dynamic motions. The tests were exposed on GafChromic EBT3 films. The first test is a regular (no motion and MLC static while beam is on) Picket Fence test used as baseline. The second test includes simultaneous collimator and couch rotation, each stripe corresponding to a differentmore » rotation speed. Errors in these tests were introduced (0.5 degree and 1 degree error in rotation synchronization) to assess the error sensitivity of this test. The second test is similar to the regular Picket Fence but now including dynamic MLC motion and couch translation (including acceleration during delivery) while the beam is on. Finally in the third test, which is a combination of the first and second test, the Picket Fence pattern is delivered using synchronized collimator and couch rotation and synchronized dynamic MLC and couch translation including acceleration. Films were analyzed with FilmQA Pro. Results: The distance between the peaks in the dose profile where measured (18.5cm away from the isocentre in the inplane direction where non synchronized rotation would have the largest effect) and compared to the regular Picket Fence tests. For well synchronized motions distances between peaks where between 24.9–25.4 mm identical to the regular Picket Fence test. This range increased to 24.4–26.4mm and 23.4–26.4mm for 0.5 degree and 1 degree error respectively. The amplitude also decreased up to 15% when errors are introduced. Conclusion: We demonstrated that the Roucoulette tests can be used as a quality control tests for trajectory treatment delivery using synchronized dynamic motion.« less

  3. Dynamical Stability and Long-term Evolution of Rotating Stellar Systems

    NASA Astrophysics Data System (ADS)

    Varri, Anna L.; Vesperini, E.; McMillan, S. L. W.; Bertin, G.

    2011-05-01

    We present the first results of an extensive survey of N-body simulations designed to investigate the dynamical stability and the long-term evolution of two new families of self-consistent stellar dynamical models, characterized by the presence of internal rotation. The first family extends the well-known King models to the case of axisymmetric systems flattened by solid-body rotation while the second family is characterized by differential rotation. The equilibrium configurations thus obtained can be described in terms of two dimensionless parameters, which measure the concentration and the amount of rotation, respectively. Slowly rotating configurations are found to be dynamically stable and we followed their long-term evolution, in order to evaluate the interplay between collisional relaxation and angular momentum transport. We also studied the stability of rapidly rotating models, which are characterized by the presence of a toroidal core embedded in an otherwise quasi-spherical configuration. In both cases, a description in terms of the radial and global properties, such as the ratio between the ordered kinetic energy and the gravitational energy of the system, is provided. Because the role of angular momentum in the process of cluster formation is only partly understood, we also undertook a preliminary investigation of the violent relaxation of simple systems initially characterized by approximate solid-body rotation. The properties of the final equilibrium configurations thus obtained are compared with those of the above-described family of differentially rotating models.

  4. Numerical Simulation of Earth Pressure on Head Chamber of Shield Machine with FEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li Shouju; Kang Chengang; Sun, Wei

    2010-05-21

    Model parameters of conditioned soils in head chamber of shield machine are determined based on tree-axial compression tests in laboratory. The loads acting on tunneling face are estimated according to static earth pressure principle. Based on Duncan-Chang nonlinear elastic constitutive model, the earth pressures on head chamber of shield machine are simulated in different aperture ratio cases for rotating cutterhead of shield machine. Relationship between pressure transportation factor and aperture ratio of shield machine is proposed by using aggression analysis.

  5. National Trends in Surgery for Rotator Cuff Disease in Korea

    PubMed Central

    2017-01-01

    The objective of this study was to investigate the national trends in rotator cuff surgery in Korea and analyze hospital type-specific trends. We analyzed a nationwide database acquired from the Korean Health Insurance Review and Assessment Service (HIRA) from 2007 to 2015. International Classification of Diseases, 10th revision (ICD-10) codes, procedure codes, and arthroscopic device code were used to identify patients who underwent surgical treatment for rotator cuff disease. A total of 383,719 cases of rotator cuff surgeries were performed from 2007 to 2015. The mean annual percentage change in the age-adjusted rate of rotator cuff surgery per population of 100,000 persons rapidly increased from 2007 to 2012 (53.3%, P < 0.001), while that between 2012 to 2015 remained steady (2.3%, P = 0.34). The proportion of arthroscopic surgery among all rotator cuff surgeries steadily rose from 89.9% in 2007 to 96.8% in 2015 (P < 0.001). In terms of hospital types, the rate of rotator cuff surgery increased to the greatest degree in hospitals with 30–100 inpatient beds, and isolated acromioplasty procedure accounted for a larger proportion of the rotator cuff surgeries in small hospitals and clinics compared to large hospitals. Overall, our findings indicate that cases of rotator cuff surgery have increased rapidly recently in Korea, of which arthroscopic surgeries account for the greatest proportion. While rotator cuff surgery is a popular procedure that is commonly performed even in small hospitals, there was a difference in the component ratio of the procedure code in accordance with hospital type. PMID:28049250

  6. Adaptive changes in the dominant shoulders of female professional overhead athletes: mutual association and relation to shoulder injury.

    PubMed

    Tonin, Katarina; Stražar, Klemen; Burger, Helena; Vidmar, Gaj

    2013-09-01

    The aim of our study was to evaluate adaptive changes in the dominant shoulders of female professional overhead athletes, their mutual association, and relation between adaptive changes and shoulder injury. Thirty-six female professional volleyball and handball players were divided into two groups: 14 athletes were included in the symptomatic group (positive shoulder injury history and specific shoulder tests) and 22 athletes were included in the asymptomatic group (negative shoulder injury history and specific shoulder tests). Clinical examinations with specific shoulder tests, evaluation of rotational mobility, and symptoms of malposition and dyskinesis of the dominant scapula (SICK scapula syndrome) were performed. Glenohumeral rotators were isokinetically tested at 60 and 150°/s, with evaluation of stability ratios and rotator fatigability. On average, the participants had decreased internal rotation (P<0.001) and increased external rotation (P<0.001), lower spiking (P<0.01 at 60 and 150°/s) and conventional ratios (P≤0.01 at 60 and 150°/s), lower eccentric external rotator peak torques (eER) (P≤0.05 at 60 and 150°/s), and marginally lower eccentric internal rotator peak torques at 60°/s (P=0.061) on the dominant side compared with the nondominant side. The symptomatic group showed decreased ER (P=0.021), higher deficit of dominant eER at 60°/s (P=0.049), and higher fatigability of internal (P=0.013) and external rotators (P=0.028). The athletes with increased ER had more scapular lateralization (ρ=0.340, P=0.042), higher spiking ratios at 60°/s (ρ=0.349, P=0.037) and 150°/s (ρ=0.330, P=0.049), and lower cocking ratios at 60°/s (ρ=-0.477, P=0.003). Decreased dominant ER, higher deficit of dominant eccentric ER peak torques, and higher dominant rotator fatigability correlate with previous shoulder pain/injury. Different adaptive changes (rotational mobility, SICK scapula signs, and glenohumeral muscular imbalance) are inter-related. As a form of both prevention and rehabilitation for the athletes at risk, we recommend individually adjusted shoulder training on the basis of clinical and isokinetic testing.

  7. Experimental investigation of the microscale rotor-stator cavity flow with rotating superhydrophobic surface

    NASA Astrophysics Data System (ADS)

    Wang, Chunze; Tang, Fei; Li, Qi; Wang, Xiaohao

    2018-03-01

    The flow characteristics of microscale rotor-stator cavity flow and the drag reduction mechanism of the superhydrophobic surface with high shearing stress were investigated. A microscale rotating flow testing system was established based on micro particle image velocimetry (micro-PIV), and the flow distribution under different Reynolds numbers (7.02 × 103 ≤ Re ≤ 3.51 × 104) and cavity aspect ratios (0.013 ≤ G ≤ 0.04) was measured. Experiments show that, for circumferential velocity, the flow field distributes linearly in rotating Couette flow in the case of low Reynolds number along the z-axis, while the boundary layer separates and forms Batchelor flow as the Reynolds number increases. The separation of the boundary layer is accelerated with the increase of cavity aspect ratio. The radial velocities distribute in an S-shape along the z-axis. As the Reynolds number and cavity aspect ratio increase, the maximum value of radial velocity increases, but the extremum position at rotating boundary remains at Z* = 0.85 with no obvious change, while the extremum position at the stationary boundary changes along the z-axis. The model for the generation of flow disturbance and the transmission process from the stationary to the rotating boundary was given by perturbation analysis. Under the action of superhydrophobic surface, velocity slip occurs near the rotating boundary and the shearing stress reduces, which leads to a maximum drag reduction over 51.4%. The contours of vortex swirling strength suggest that the superhydrophobic surface can suppress the vortex swirling strength and repel the vortex structures, resulting in the decrease of shearing Reynolds stress and then drag reduction.

  8. Activation of biceps femoris long head reduces tibiofemoral anterior shear force and tibial internal rotation torque in healthy subjects

    PubMed Central

    Azmi, Nur Liyana; Ding, Ziyun; Xu, Rui

    2018-01-01

    The anterior cruciate ligament (ACL) provides resistance to tibial internal rotation torque and anterior shear at the knee. ACL deficiency results in knee instability. Optimisation of muscle contraction through functional electrical stimulation (FES) offers the prospect of mitigating the destabilising effects of ACL deficiency. The hypothesis of this study is that activation of the biceps femoris long head (BFLH) reduces the tibial internal rotation torque and the anterior shear force at the knee. Gait data of twelve healthy subjects were measured with and without the application of FES and taken as inputs to a computational musculoskeletal model. The model was used to investigate the optimum levels of BFLH activation during FES gait in reducing the anterior shear force to zero. This study found that FES significantly reduced the tibial internal rotation torque at the knee during the stance phase of gait (p = 0.0322) and the computational musculoskeletal modelling revealed that a mean BFLH activation of 20.8% (±8.4%) could reduce the anterior shear force to zero. At the time frame when the anterior shear force was zero, the internal rotation torque was reduced by 0.023 ± 0.0167 Nm/BW, with a mean 188% reduction across subjects (p = 0.0002). In conclusion, activation of the BFLH is able to reduce the tibial internal rotation torque and the anterior shear force at the knee in healthy control subjects. This should be tested on ACL deficient subject to consider its effect in mitigating instability due to ligament deficiency. In future clinical practice, activating the BFLH may be used to protect ACL reconstructions during post-operative rehabilitation, assist with residual instabilities post reconstruction, and reduce the need for ACL reconstruction surgery in some cases. PMID:29304102

  9. Activation of biceps femoris long head reduces tibiofemoral anterior shear force and tibial internal rotation torque in healthy subjects.

    PubMed

    Azmi, Nur Liyana; Ding, Ziyun; Xu, Rui; Bull, Anthony M J

    2018-01-01

    The anterior cruciate ligament (ACL) provides resistance to tibial internal rotation torque and anterior shear at the knee. ACL deficiency results in knee instability. Optimisation of muscle contraction through functional electrical stimulation (FES) offers the prospect of mitigating the destabilising effects of ACL deficiency. The hypothesis of this study is that activation of the biceps femoris long head (BFLH) reduces the tibial internal rotation torque and the anterior shear force at the knee. Gait data of twelve healthy subjects were measured with and without the application of FES and taken as inputs to a computational musculoskeletal model. The model was used to investigate the optimum levels of BFLH activation during FES gait in reducing the anterior shear force to zero. This study found that FES significantly reduced the tibial internal rotation torque at the knee during the stance phase of gait (p = 0.0322) and the computational musculoskeletal modelling revealed that a mean BFLH activation of 20.8% (±8.4%) could reduce the anterior shear force to zero. At the time frame when the anterior shear force was zero, the internal rotation torque was reduced by 0.023 ± 0.0167 Nm/BW, with a mean 188% reduction across subjects (p = 0.0002). In conclusion, activation of the BFLH is able to reduce the tibial internal rotation torque and the anterior shear force at the knee in healthy control subjects. This should be tested on ACL deficient subject to consider its effect in mitigating instability due to ligament deficiency. In future clinical practice, activating the BFLH may be used to protect ACL reconstructions during post-operative rehabilitation, assist with residual instabilities post reconstruction, and reduce the need for ACL reconstruction surgery in some cases.

  10. Performance after rotator cuff tear and operative treatment: a case-control study of major league baseball pitchers.

    PubMed

    Namdari, Surena; Baldwin, Keith; Ahn, Albert; Huffman, G Russell; Sennett, Brian J

    2011-01-01

    Little is known about pitching performance or lack of it among Major League Baseball (MLB) pitchers who undergo operative treatment of rotator cuff tears. To assess pitching performance outcomes in MLB players who needed operative treatment of rotator cuff tears and to compare performance in these athletes with that in a control group of MLB players. Case-control study. Publicly available player profiles, press releases, and team injury reports. Thirty-three MLB pitchers with documented surgery to treat rotator cuff tears and 117 control pitchers who did not have documented rotator cuff tears were identified. Major League Baseball pitching attrition and performance variables. Players who underwent rotator cuff surgery were no more likely not to play than control players. Performance variables of players who underwent surgery improved after surgery but never returned to baseline preoperative status. Players who needed rotator cuff surgery typically were more experienced and had better earned run averages than control players. Pitchers who had symptomatic rotator cuff tears that necessitated operative treatment tended to decline gradually in performance leading up to their operations and to improve gradually over the next 3 seasons. In contrast to what we expected, they did not have a greater attrition rate than their control counterparts; however, their performances did not return to preoperative levels over the course of the study.

  11. The 2D dynamics of radiative zones of low-mass stars

    NASA Astrophysics Data System (ADS)

    Hypolite, D.; Mathis, S.; Rieutord, M.

    2018-02-01

    Context. Helioseismology and asteroseismology allow us to probe the differential rotation deep within low-mass stars. In the solar convective envelope, the rotation varies with latitude with an equator rotating faster than the pole, which results in a shear applied on the radiative zone below. However, a polar acceleration of the convective envelope can be obtained through 3D numerical simulations in other low-mass stars and the dynamical interaction of the surface convective envelope with the radiative core needs to be investigated in the general case. Aim. In the context of secular evolution, we aim to describe the dynamics of the radiative core of low-mass stars to get a deeper understanding of the internal transport of angular momentum in such stars, which results in a solid rotation in the Sun from 0.7R⊙ to 0.2R⊙ and a weak radial core-envelope differential rotation in solar-type stars. This study requires at least a 2D description to capture the latitudinal variations of the differential rotation. Methods: We build 2D numerical models of a radiative core on the top of which we impose a latitudinal shear so as to reproduce a conical or cylindrical differential rotation in a convective envelope. We perform a systematic study over the Rossby number ℛo = ΔΩ/2Ω0 measuring the latitudinal differential rotation at the radiative-convective interface. We provide a 2D description of the differential rotation and the associated meridional circulation in the incompressible and stably stratified cases using the Boussinesq approximation. Results: The imposed shear generates a geostrophic flow implying a cylindrical differential rotation in the case of an isotropic viscosity. When compared to the baroclinic flow that arises from the stable stratification, we find that the geostrophic flow is dominant when the Rossby number is high enough (ℛo ≥ 1) with a cylindrical rotation profile. For low Rossby numbers (ℛo < 1), the baroclinic solution dominates with a quasi-shellular rotation profile. Using scaling laws from 3D simulations, we show that slow rotators (Ω0 < 30Ω⊙) are expected to have a cylindrical rotation profile. Fast rotators (Ω0 > 30Ω⊙) may have a shellular profile at the beginning of the main sequence in stellar radiative zones. Conclusions: This study enables us to predict different types of differential rotation and emphasizes the need for a new generation of 2D rotating stellar models developed in synergy with 3D numerical simulations. The shear induced by a surface convective zone has a strong impact on the dynamics of the underlying radiative zone in low-mass stars. However, it cannot produce a flat internal rotation profile in a solar configuration calling for additional processes for the transport of angular momentum in both radial and latitudinal directions.

  12. Absolute plate motions and true polar wander in the absence of hotspot tracks.

    PubMed

    Steinberger, Bernhard; Torsvik, Trond H

    2008-04-03

    The motion of continents relative to the Earth's spin axis may be due either to rotation of the entire Earth relative to its spin axis--true polar wander--or to the motion of individual plates. In order to distinguish between these over the past 320 Myr (since the formation of the Pangaea supercontinent), we present here computations of the global average of continental motion and rotation through time in a palaeomagnetic reference frame. Two components are identified: a steady northward motion and, during certain time intervals, clockwise and anticlockwise rotations, interpreted as evidence for true polar wander. We find approximately 18 degrees anticlockwise rotation about 250-220 Myr ago and the same amount of clockwise rotation about 195-145 Myr ago. In both cases the rotation axis is located at about 10-20 degrees W, 0 degrees N, near the site that became the North American-South American-African triple junction at the break-up of Pangaea. This was followed by approximately 10 degrees clockwise rotation about 145-135 Myr ago, followed again by the same amount of anticlockwise rotation about 110-100 Myr ago, with a rotation axis in both cases approximately 25-50 degrees E in the reconstructed area of North Africa and Arabia. These rotation axes mark the maxima of the degree-two non-hydrostatic geoid during those time intervals, and the fact that the overall net rotation since 320 Myr ago is nearly zero is an indication of long-term stability of the degree-two geoid and related mantle structure. We propose a new reference frame, based on palaeomagnetism, but corrected for the true polar wander identified in this study, appropriate for relating surface to deep mantle processes from 320 Myr ago until hotspot tracks can be used (about 130 Myr ago).

  13. Job rotation designed to prevent musculoskeletal disorders and control risk in manufacturing industries: A systematic review.

    PubMed

    Padula, Rosimeire Simprini; Comper, Maria Luiza Caires; Sparer, Emily H; Dennerlein, Jack T

    2017-01-01

    To better understand job rotation in the manufacturing industry, we completed a systematic review asking the following questions: 1) How do job-rotation programs impact work-related musculoskeletal disorders (MSDs) and related risk control for these MSDs, as well as psychosocial factors? and 2) How best should the job rotation programs be designed? We searched MEDLINE, EMBASE, Business Source Premier, ISI Web of Knowledge, CINAHL, PsyINFO, Scopus, and SciELO databases for articles published in peer-reviewed journals. Eligible studies were examined by two independent reviewers for relevance (population of manufacturing workers, outcomes of musculoskeletal disorders, physical factors, psychosocial factors, and strategies used in job-rotation implantation) and methodological quality rating. From 10,809 potential articles, 71 were read for full text analysis. Of the 14 studies included for data extraction, two were non-randomized control trial studies, one was a case-control study, and 11 were cross-sectional comparisons. Only one, with a case-control design, was scored with good methodological quality. Currently, weak evidence exists supporting job rotation as a strategy for the prevention and control of musculoskeletal disorders. Job rotation did not appear to reduce the exposure of physical risk factors; yet, there are positive correlations between job rotation and higher job satisfaction. Worker training has been described as a crucial component of a successful job-rotation program. The studies reported a range of parameters used to implement and measure job-rotation programs. More rigorous studies are needed to better understand the full impact of job rotation on production and health. CRD42014013319. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Asymmetric pelvic and hip rotation in children with bilateral cerebral palsy: uni- or bilateral femoral derotation osteotomy?

    PubMed

    Niklasch, M; Döderlein, L; Klotz, M C; Braatz, F; Wolf, S I; Dreher, T

    2015-02-01

    Internal rotation gait is common among children with bilateral cerebral palsy. However, despite bilaterally increased femoral anteversion asymmetric internal rotation gait is often found. Femoral derotation osteotomy (FDO) is commonly performed bilaterally. Variable functional outcomes are reported especially in cases with mild internal hip rotation during gait and abnormal preoperative pelvic rotation. A major question is if a unilateral treatment of the more involved side in asymmetric cases leads to a comparable or even superior outcome. One hundred and nine children with spastic bilateral CP treated with FDO with pre- and 1-year postoperative 3D gait analysis were retrospectively collected. The asymmetry was calculated from the preoperative difference between both limbs in hip rotation obtained by 3D gait analysis. Twenty-eight children with asymmetry larger than 20° were selected and classified into two groups, according to whether they obtained a unilateral or bilateral FDO. Preoperative clinical examination and pre- and postoperative hip and pelvic rotation in gait analysis on the more and the less involved side did not differ significantly between both groups. Interestingly, in both groups, hip rotation did not change significantly in less-involved limbs, although intraoperative derotation averaged 25°. After unilateral FDO a significant change in pelvic rotation resulted, whereas this was not found after bilateral FDO. The results of this study suggest that unilateral FDO in children with asymmetric internal rotation gait leads to a comparable functional outcome compared to bilateral treatment. Furthermore, it was shown for the first time that considering the asymmetry has a positive effect on pelvic rotation. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. A Case for Basic Rotating Detonation Engine Research

    NASA Technical Reports Server (NTRS)

    Paxson, Daniel E.

    2016-01-01

    A brief review is provided covering the benefits to air breathing and chemical rocket propulsion found from pressure gain combustion in general, and rotating detonation in particular. Challenges are also identified.

  16. The influence of applied internal and external rotation on the pivot shift phenomenon.

    PubMed

    Kopf, Sebastian; Musahl, Volker; Perka, Carsten; Kauert, Ralf; Hoburg, Arnd; Becker, Roland

    2017-04-01

    The pivot shift test is performed in different techniques and the rotation of the tibia seems to have a significant impact on the amount of the pivot shift phenomenon. It has been hypothesised that external rotation will increase the phenomenon due to less tension at the iliotibial band in knee extension. Twenty-four patients with unilateral anterior cruciate ligament insufficiency were included prospectively. The pivot shift test was performed bilaterally in internal and external tibial rotation under general anaesthesia. Knee motion was captured using a femoral and a tibial inertial sensor. The difference between positive and negative peak values in Euclidean norm of acceleration was calculated to evaluate the amount of the pivot shift phenomenon. The pivot shift phenomenon was significantly increased in patients with ACL insufficiency when the test was performed in external [mean 5.2 ms - 2 (95% CI 4.3-6.0)] compared to internal tibial rotation [mean 4.4 ms - 2 (95% CI 3.5-5.4)] (p = 0.002). In healthy, contralateral knees did not show any difference between external [mean 4.0 ms - 2 (95% CI 3.3-4.7)] and internal tibial rotation [mean 4.0 ms - 2 (95% CI 3.4-4.6)] (ns). The pivot shift phenomenon was increased with external rotation in ACL-insufficient knees, and therefore, one should perform the pivot shift test, rather, in external rotation to easily evoke the, sometimes difficult to detect, pivot shift phenomenon. I (diagnostic study).

  17. DIZZINESS AND HEAD INJURY.

    PubMed

    BARBER, H O

    1965-05-01

    Dizziness, whether vague or specifically rotational, is a common sequel to head injury, and is often postural. One hundred and sixty-five patients with this symptom were examined. The simple posture tests employed to detect positional nystagmus are described. This physical finding was present in one-quarter of the entire group, and in nearly one-half of cases of longitudinal fracture of temporal bone. In such cases, it is an objective finding that corresponds precisely to the patient's complaint of vertigo.Transverse fracture of temporal bone destroys the inner ear in both cochlear and vestibular parts. Longitudinal fracture is commoner and causes bleeding from the ear; inner-ear damage is usually minor.In the rare cases where persisting postural vertigo and positional nystagmus are disabling, relief of the symptom may be achieved by vestibular denervation of the affected side.

  18. Effect of a novel mobilization with movement procedure on anterolateral ankle impingement - A case report.

    PubMed

    Anandkumar, Sudarshan

    2018-07-01

    This case report describes a 50-year-old male who presented with right anterolateral ankle pain managed unsuccessfully with rest, medications, bracing, injection, physical therapy, and massage therapy. Clinical diagnosis of anterolateral ankle impingement was based on concordant symptom reproduction with palpatory tenderness and a positive lateral synovial impingement test. This case report is a potential first time description of the successful management of anterolateral ankle impingement utilizing a novel Mulligan's mobilization with movement procedure (consisting of internal rotation of the distal tibia) and taping with immediate improvements noted in pain, range of motion, and function. The patient was seen twice a week and was discharged after four treatment sessions. A follow-up after 4 months revealed that the patient was pain free and fully functional.

  19. Motion Sickness-Induced Food Aversions in the Squirrel Monkey

    NASA Technical Reports Server (NTRS)

    Roy, M. Aaron; Brizzee, Kenneth R.

    1979-01-01

    Conditioned aversions to colored, flavored water were established in Squirrel monkeys (Saimiri sciureus) by following consumption with 90 min of simultaneous rotational and vertical stimulation. The experimental group (N= 13) drank significantly less of the green, almond-flavored test solution than did the control group (N=14) during three post-treatment preference testing days. Individual differences were noted in that two experimental monkeys readily drank the test solution after rotational stimulation. Only two of the experimental monkeys showed emesis during rotation, yet 10 monkeys in this group developed an aversion. These results suggest that: (1) motion sickness can be readily induced in Squirrel monkeys with simultaneous rotational and vertical stimulation, and (2) that conditioned food aversions are achieved in the absence of emesis in this species.

  20. An Investigation of the Visual and Tactile Spatial Reasoning Abilities of the Hearing Impaired/Deaf Student.

    ERIC Educational Resources Information Center

    Hauptman, Anna R.

    Two experiments involving 42 students from the Model Secondary School for the Deaf investigated both the visual and tactile components in the processing of spatial information. Test measures used were the Figures Rotations Test, Group Embedded Figures Test, and Tactile Rotations Test. The study suggested that spatial reasoning is a determining…

  1. A NEW CLINICAL MUSCLE FUNCTION TEST FOR ASSESSMENT OF HIP EXTERNAL ROTATION STRENGTH: AUGUSTSSON STRENGTH TEST.

    PubMed

    Augustsson, Jesper

    2016-08-01

    Dynamic clinical tests of hip strength applicable on patients, non-athletes and athletes alike, are lacking. The aim of this study was therefore to develop and evaluate the reliability of a dynamic muscle function test of hip external rotation strength, using a novel device. A second aim was to determine if gender differences exist in absolute and relative hip strength using the new test. Fifty-three healthy sport science students (34 women and 19 men) were tested for hip external rotation strength using a device that consisted of a strap connected in series with an elastic resistance band loop, and a measuring tape connected in parallel with the elastic resistance band. The test was carried out with the subject side lying, positioned in 45 ° of hip flexion and the knees flexed to 90 ° with the device firmly fastened proximally across the knees. The subject then exerted maximal concentric hip external rotation force against the device thereby extending the elastic resistance band. The displacement achieved by the subject was documented by the tape measure and the corresponding force production was calculated. Both right and left hip strength was measured. Fifteen of the subjects were tested on repeated occasions to evaluate test-retest reliability. No significant test-retest differences were observed. Intra-class correlation coefficients ranged 0.93-0.94 and coefficients of variation 2.76-4.60%. In absolute values, men were significantly stronger in hip external rotation than women (right side 13.2 vs 11.0 kg, p = 0.001, left side 13.2 vs 11.5 kg, p = 0.002). There were no significant differences in hip external rotation strength normalized for body weight (BW) between men and women (right side 0.17 kg/BW vs 0.17 kg/BW, p = 0.675, left side 0.17 kg/BW vs 0.18 kg/BW, p = 0.156). The new muscle function test showed high reliability and thus could be useful for measuring dynamic hip external rotation strength in patients, non-athletes and athletes. The test is practical and easy to perform in any setting and could therefore provide additional information to the common clinical hip examination, in the rehabilitation or research setting, as well as when conducting on-the-field testing in sports. 3.

  2. Anterior stability of the reverse shoulder arthroplasty depending on implant configuration and rotator cuff condition.

    PubMed

    Pastor, Marc-Frederic; Kraemer, Manuel; Wellmann, Mathias; Hurschler, Christof; Smith, Tomas

    2016-11-01

    The aim of this study was to investigate the stabilizing influence of the rotator cuff as well as the importance of glenosphere and onlay configuration on the anterior stability of the reverse total shoulder replacement (RTSR). A reverse total shoulder replacement was implanted into eight human cadaveric shoulders, and biomechanical testing was performed under three conditions: after implantation of the RTSR, after additional dissection of the subscapularis tendon, and after additional dissection of the infraspinatus and teres minor tendon. Testing was performed in 30° of abduction and three rotational positions: 30° internal rotation, neutral rotation, and 30° external rotation. Furthermore, the 38-mm and 42-mm glenospheres were tested in combination with a standard and a high-mobility humeral onlay. A gradually increased force was applied to the glenohumeral joint in anterior direction until the RTSR dislocated. The 42-mm glenosphere showed superior stability compared with the 38-mm glenosphere. The standard humeral onlay required significantly higher anterior dislocation forces than the more shallow high-mobility onlay. External rotation was the most stable position. Furthermore, isolated detachment of the subscapularis and combined dissection of the infraspinatus, teres minor, and subscapularis tendon increased anterior instability. This study showed superior stability with the 42-mm glenosphere and the more conforming standard onlay. External rotation was the most stable position. Detachment of the subscapularis as well as dissection of the complete rotator cuff decreased anterior stability.

  3. Experimental Investigation of Rotating Stall in a Research Multistage Axial Compressor

    NASA Technical Reports Server (NTRS)

    Lepicovsky, Jan; Braunscheidel, Edward P.; Welch, Gerard E.

    2007-01-01

    A collection of experimental data acquired in the NASA low-speed multistage axial compressor while operated in rotating stall is presented in this paper. The compressor was instrumented with high-response wall pressure modules and a static pressure disc probe for in-flow measurement, and a split-fiber probe for simultaneous measurements of velocity magnitude and flow direction. The data acquired to-date have indicated that a single fully developed stall cell rotates about the flow annulus at 50.6% of the rotor speed. The stall phenomenon is substantially periodic at a fixed frequency of 8.29 Hz. It was determined that the rotating stall cell extends throughout the entire compressor, primarily in the axial direction. Spanwise distributions of the instantaneous absolute flow angle, axial and tangential velocity components, and static pressure acquired behind the first rotor are presented in the form of contour plots to visualize different patterns in the outer (midspan to casing) and inner (hub to mid-span) flow annuli during rotating stall. In most of the cases observed, the rotating stall started with a single cell. On occasion, rotating stall started with two emerging stall cells. The root cause of the variable stall cell count is unknown, but is not attributed to operating procedures.

  4. Three-dimensional rotational plasma flows near solid surfaces in an axial magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gorshunov, N. M., E-mail: gorshunov-nm@nrcki.ru; Potanin, E. P., E-mail: potanin45@yandex.ru

    2016-11-15

    A rotational flow of a conducting viscous medium near an extended dielectric disk in a uniform axial magnetic field is analyzed in the magnetohydrodynamic (MHD) approach. An analytical solution to the system of nonlinear differential MHD equations of motion in the boundary layer for the general case of different rotation velocities of the disk and medium is obtained using a modified Slezkin–Targ method. A particular case of a medium rotating near a stationary disk imitating the end surface of a laboratory device is considered. The characteristics of a hydrodynamic flow near the disk surface are calculated within the model ofmore » a finite-thickness boundary layer. The influence of the magnetic field on the intensity of the secondary flow is studied. Calculations are performed for a weakly ionized dense plasma flow without allowance for the Hall effect and plasma compressibility. An MHD flow in a rotating cylinder bounded from above by a retarding cap is considered. The results obtained can be used to estimate the influence of the end surfaces on the main azimuthal flow, as well as the intensities of circulating flows in various devices with rotating plasmas, in particular, in plasma centrifuges and laboratory devices designed to study instabilities of rotating plasmas.« less

  5. EXERCISE REHABILITATION IN THE NON-OPERATIVE MANAGEMENT OF ROTATOR CUFF TEARS: A REVIEW OF THE LITERATURE

    PubMed Central

    Edwards, Peter; Ebert, Jay; Joss, Brendan; Bhabra, Gev; Ackland, Tim; Wang, Allan

    2016-01-01

    The incidence of rotator cuff tears increases with age, with full-thickness rotator cuff tears present in approximately 25% of individuals in their sixties, and more than 50% of those in their eighties. While surgery is considered an effective treatment, recurrent tears at the insertion site are common, especially with degenerative tears, which are frequent in the older population. More recently, there has been increasing interest in exercise rehabilitation and physical therapy as a means to manage partial and full thickness tears of the rotator cuff by addressing weakness and functional deficits. Recent studies have suggested that patients opting for physical therapy have demonstrated high satisfaction, an improvement in function, and success in avoiding surgery. When considering the increasing rate of shoulder surgery and the associated economic and social burden rotator cuff surgery places on both the patient and the health care system, non-surgical management such as physical therapy and exercise may, in selected cases, be a treatment alternative to surgical repair. The purpose of this clinical commentary is to provide an overview of rotator cuff pathology and pathogenesis, and to present an evidence-based case for the role of conservative rehabilitation in the management of rotator cuff injuries. Level of Evidence Level 5 PMID:27104061

  6. Measurements of the Structure of the Plasma Rotation in Slowly Rotating Tearing Modes in DIII-D

    NASA Astrophysics Data System (ADS)

    Taylor, N. Z.; Ferraro, N. M.; La Haye, R. J.; Petty, C. C.; Bowman, C.

    2014-10-01

    A helically modified ion flow by an island can lead to helical ion polarization currents which can affect tearing mode stability. This issue is of particular importance to ITER where large inertia and relatively low torque will likely result in low rotation. In DIII-D cases either (1) a m/n = 2/1 mode is slowed down to ~1 kHz (faster than the inverse wall time) by near balanced neutral beams or (2) an island is entrained by applied rotating n = 1 magnetic field at 10 Hz (slower than the inverse wall time). The n = 1 island structure is measured with electron cyclotron emission radiometry. The ion rotation and temperature are measured by fast resolution (274 μ s) charge exchange recombination (CER) spectroscopy in the 1 kHz freely rotating case and by standard CER (5 ms) in the 10 Hz entrainment. Tangential and vertical CER arrays allow for the radial profile of the helically perturbed rotation to be determined. A comparison of the measured nonlinear island structures with that from the linear resistive stability code M3D-C1 will be presented. Work supported in part by the US Department of Energy under DE-FG02-95ER54309 and DE-FC02-04ER54698.

  7. The kinematic determinants of anuran swimming performance: an inverse and forward dynamics approach.

    PubMed

    Richards, Christopher T

    2008-10-01

    The aims of this study were to explore the hydrodynamic mechanism of Xenopus laevis swimming and to describe how hind limb kinematics shift to control swimming performance. Kinematics of the joints, feet and body were obtained from high speed video of X. laevis frogs (N=4) during swimming over a range of speeds. A blade element approach was used to estimate thrust produced by both translational and rotational components of foot velocity. Peak thrust from the feet ranged from 0.09 to 0.69 N across speeds ranging from 0.28 to 1.2 m s(-1). Among 23 swimming strokes, net thrust impulse from rotational foot motion was significantly higher than net translational thrust impulse, ranging from 6.1 to 29.3 N ms, compared with a range of -7.0 to 4.1 N ms from foot translation. Additionally, X. laevis kinematics were used as a basis for a forward dynamic anuran swimming model. Input joint kinematics were modulated to independently vary the magnitudes of foot translational and rotational velocity. Simulations predicted that maximum swimming velocity (among all of the kinematics patterns tested) requires that maximal translational and maximal rotational foot velocity act in phase. However, consistent with experimental kinematics, translational and rotational motion contributed unequally to total thrust. The simulation powered purely by foot translation reached a lower peak stroke velocity than the pure rotational case (0.38 vs 0.54 m s(-1)). In all simulations, thrust from the foot was positive for the first half of the power stroke, but negative for the second half. Pure translational foot motion caused greater negative thrust (70% of peak positive thrust) compared with pure rotational simulation (35% peak positive thrust) suggesting that translational motion is propulsive only in the early stages of joint extension. Later in the power stroke, thrust produced by foot rotation overcomes negative thrust (due to translation). Hydrodynamic analysis from X. laevis as well as forward dynamics give insight into the differential roles of translational and rotational foot motion in the aquatic propulsion of anurans, providing a mechanistic link between joint kinematics and swimming performance.

  8. Effects of rotational symmetry breaking in polymer-coated nanopores

    NASA Astrophysics Data System (ADS)

    Osmanović, D.; Kerr-Winter, M.; Eccleston, R. C.; Hoogenboom, B. W.; Ford, I. J.

    2015-01-01

    The statistical theory of polymers tethered around the inner surface of a cylindrical channel has traditionally employed the assumption that the equilibrium density of the polymers is independent of the azimuthal coordinate. However, simulations have shown that this rotational symmetry can be broken when there are attractive interactions between the polymers. We investigate the phases that emerge in these circumstances, and we quantify the effect of the symmetry assumption on the phase behavior of the system. In the absence of this assumption, one can observe large differences in the equilibrium densities between the rotationally symmetric case and the non-rotationally symmetric case. A simple analytical model is developed that illustrates the driving thermodynamic forces responsible for this symmetry breaking. Our results have implications for the current understanding of the behavior of polymers in cylindrical nanopores.

  9. Effects of rotational symmetry breaking in polymer-coated nanopores

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Osmanović, D.; Hoogenboom, B. W.; Ford, I. J.

    2015-01-21

    The statistical theory of polymers tethered around the inner surface of a cylindrical channel has traditionally employed the assumption that the equilibrium density of the polymers is independent of the azimuthal coordinate. However, simulations have shown that this rotational symmetry can be broken when there are attractive interactions between the polymers. We investigate the phases that emerge in these circumstances, and we quantify the effect of the symmetry assumption on the phase behavior of the system. In the absence of this assumption, one can observe large differences in the equilibrium densities between the rotationally symmetric case and the non-rotationally symmetricmore » case. A simple analytical model is developed that illustrates the driving thermodynamic forces responsible for this symmetry breaking. Our results have implications for the current understanding of the behavior of polymers in cylindrical nanopores.« less

  10. Supination and Pronation Strength Deficits Persist at 2-4 Years after Treatment of Distal Radius Fractures.

    PubMed

    Ploegmakers, Joris; The, Bertram; Wang, Allan; Brutty, Mike; Ackland, Tim

    2015-10-01

    Forearm rotation is a key function in the upper extremity. Following distal radius fracture, residual disability may occur in tasks requiring forearm rotation. The objectives of this study are to define pronation and supination strength profiles tested through the range of forearm rotation in normal individuals, and to evaluate the rotational strength profiles and rotational strength deficits across the testing range in a cohort of patients treated for distal radius fracture associated with an ulnar styloid base fracture. In a normative cohort of 29 subjects the supination strength profile showed an increasing linear relationship from supination to pronation. Twelve subjects were evaluated 2-4 years after anatomical open reduction and volar plate fixation of a distal radius fracture. The injured wrist was consistently weaker (corrected for hand dominance) in both supination and pronation strength in all testing positions, with the greatest loss in 60 degrees supination. Mean supination strength loss across all testing positions was significantly correlated with worse PRWE scores, highlighting the importance of supination in wrist function.

  11. Dynamic interaction of rotating momentum wheels with spacecraft elements

    NASA Astrophysics Data System (ADS)

    Shankar Narayan, S.; Nair, P. S.; Ghosal, Ashitava

    2008-09-01

    In modern spacecraft with the requirement of increased accuracy of payloads, the on-orbit structural dynamic behavior of spacecraft is increasingly influencing the design and performance of spacecraft. During the integrated spacecraft testing of one of the satellites, a strong coupling between rotating momentum wheels and an earth sensor was detected. This resulted in corruption of the earth sensor data at certain wheel speeds. This paper deals with the dynamic coupling problem of a rotating momentum wheel with its support brackets affecting other subsystems of spacecraft. As part of this investigation, extensive modal tests and vibration tests were carried out on the momentum wheel bracket assembly with wheels in stationary and rotating conditions. It was found that the effects of gyroscopic forces arising out of rotating wheels are significant and this aspect needs to be taken into account while designing the mounting brackets. Results of analysis and tests were used to redesign the bracket leading to a significant reduction in the interaction and associated problems. A procedure for design of a support structure using a low-order mathematical model is also shown.

  12. Radiation from an accelerating neutral body: The case of rotation

    NASA Astrophysics Data System (ADS)

    Yarman, Tolga; Arik, Metin; Kholmetskii, Alexander L.

    2013-11-01

    When an object is bound at rest to an attractional field, its rest mass (owing to the law of energy conservation, including the mass and energy equivalence of the Special Theory of Relativity) must decrease. The mass deficiency coming into play indicates a corresponding rest energy discharge. Thus, bringing an object to a rotational motion means that the energy transferred for this purpose serves to extract just as much rest mass (or similarly "rest energy", were the speed of light in empty space taken to be unity) out of it. Here, it is shown that during angular acceleration, photons of fundamental energy are emitted, while the object is kept on being delivered to a more and more intense rotational accelerational field, being the instantaneous angular velocity of the rotating object. This fundamental energy, as seen, does not depend on anything else (such as the mass or charge of the object), and it is in harmony with Bohr's Principle of Correspondence. This means at the same time, that emission will be achieved, as long as the angular velocity keeps on increasing, and will cease right after the object reaches a stationary rotational motion (a constant centrifugal acceleration), but if the object were brought to rotation in vacuum with no friction. By the same token, one can affirm that even the rotation at a macroscopic level is quantized, and can only take on "given angular velocities" (which can only be increased, bit by bit). The rate of emission of photons of concern is, on the other hand, proportional to the angular acceleration of the object, similarly to the derivative of the tangential acceleration with respect to time. It is thus constant for a "constant angular acceleration", although the energy of the emitted photons will increase with increasing , until the rotation reaches a stationary level, after which we expect no emission --let us stress-- if the object is in rotation in vacuum, along with no whatsoever friction (such as the case of a rotating diatomic molecule, for instance). If the object reaches its final state in a given medium, say air, and "friction" is present, such as the case of a dental drill, then energy should keep being supplied to it, to overcome friction, which is present either inside the "inner mechanism of rotation" or in its surroundings. In other words, the object in the latter case, would be constantly subject to a friction force, countering its motion, and tending to make it fall to lower rotational energy states. Any fluctuations in the power supply, on the other hand, will slow down the rotating object, no matter how indiscernibly. The small decrease in the rotational velocity is yet reincreased by restoring the power supply, thus perpetually securing a stationary rotational motion. Thereby, the object in this final state, due to fluctuations in either friction or power supply, or both, shall further be expected to emit a radiation of energy , where is the final angular velocity of the object in rotation. What is more is that our team has very successfully measured what is predicted here, and they will report their experimental results in a subsequent article. The approach presented here seems to shed light on the mysterious sonoluminescence. It also triggers the possibility of sensing earthquakes due to radiation that should be emitted by the faults, on which the seismic stress keeps increasing until the crackdown. By the same token, also two colliding (neutral) objects are expected to emit radiation.

  13. Cost-Effectiveness of Reverse Total Shoulder Arthroplasty Versus Arthroscopic Rotator Cuff Repair for Symptomatic Large and Massive Rotator Cuff Tears.

    PubMed

    Makhni, Eric C; Swart, Eric; Steinhaus, Michael E; Mather, Richard C; Levine, William N; Bach, Bernard R; Romeo, Anthony A; Verma, Nikhil N

    2016-09-01

    To compare the cost-effectiveness within the United States health care system of arthroscopic rotator cuff repair versus reverse total shoulder arthroplasty in patients with symptomatic large and massive rotator cuff tears without cuff-tear arthropathy. An expected-value decision analysis was constructed comparing the costs and outcomes of patients undergoing arthroscopic rotator cuff repair and reverse total shoulder arthroplasty for large and massive rotator cuff tears (and excluding cases of cuff-tear arthropathy). Comprehensive literature search provided input data to extrapolate costs and health utility states for these outcomes. The primary outcome assessed was that of incremental cost-effectiveness ratio (ICER) of reverse total shoulder arthroplasty versus rotator cuff repair. For the base case, both arthroscopic rotator cuff repair and reverse total shoulder were superior to nonoperative care, with an ICER of $15,500/quality-adjusted life year (QALY) and $37,400/QALY, respectively. Arthroscopic rotator cuff repair was dominant over primary reverse total shoulder arthroplasty, with lower costs and slightly improved clinical outcomes. Arthroscopic rotator cuff repair was the preferred strategy as long as the lifetime progression rate from retear to end-stage cuff-tear arthropathy was less than 89%. However, when the model was modified to account for worse outcomes when reverse shoulder arthroplasty was performed after a failed attempted rotator cuff repair, primary reverse total shoulder had superior outcomes with an ICER of $90,000/QALY. Arthroscopic rotator cuff repair-despite high rates of tendon retearing-for patients with large and massive rotator cuff tears may be a more cost-effective initial treatment strategy when compared with primary reverse total shoulder arthroplasty and when assuming no detrimental impact of previous surgery on outcomes after arthroplasty. Clinical judgment should still be prioritized when formulating treatment plans for these patients. LEVEL OF EVIDENCE: Level II, economic decision analysis. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  14. Inducer Hydrodynamic Forces in a Cavitating Environment

    NASA Technical Reports Server (NTRS)

    Skelley, Stephen E.

    2004-01-01

    Marshall Space Flight Center has developed and demonstrated a measurement device for sensing and resolving the hydrodynamic loads on fluid machinery. The device - a derivative of the six-component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This rotating balance was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining the amplitude and frequency content associated with operating in various cavitation modes. The rotating balance was calibrated statically using a dead-weight load system in order to generate the 6 x 12 calibration matrix later used to convert measured voltages to engineering units. Structural modeling suggested that the rotating assembly first bending mode would be significantly reduced with the balance s inclusion. This reduction in structural stiffness was later confirmed experimentally with a hammer-impact test. This effect, coupled with the relatively large damping associated with the rotating balance waterproofing material, limited the device s bandwidth to approximately 50 Hertz Other pre-test validations included sensing the test article rotating assembly built-in imbalance for two configurations and directly measuring the assembly mass and buoyancy while submerged under water. Both tests matched predictions and confirmed the device s sensitivity while stationary and rotating. The rotating balance was then demonstrated in a water test of a full-scale Space Shuttle Main Engine high-pressure liquid oxygen pump inducer. Experimental data was collected a scaled operating conditions at three flow coefficients across a range of cavitation numbers for the single inducer geometry and radial clearance. Two distinct cavitation modes were observed symmetric tip vortex cavitation and alternate-blade cavitation. Although previous experimental tests on the same inducer demonstrated two additional cavitation modes at lower inlet pressures, these conditions proved unreachable with the rotating balance installed due to the intense dynamic environment. The sensed radial load was less influenced by flow coefficient than by cavitation number or cavitation mode although the flow coefficient range was relatively narrow. Transition from symmetric tip vortex to alternate-blade cavitation corresponded to changes in both radial load magnitude and radial load orientation relative to the inducer. Sensed moments indicated that the effective load center moved downstream during this change in cavitation mode. An occurrence of "higher+rdex cavitation" was also detected in both the stationary pressures and the rotating balance data although the frequency of the phenomena was well above the reliable bandwidth of the rotating balance. In summary the experimental tests proved both the concept and device s capability despite the limitations and confirmed that hydrodynamically-induced forces and moments develop in response to the unbalanced pressure field, which is, in turn, a product of the cavitation environment.

  15. Is the Male Advantage in Mental-Rotation Performance Task Independent? On the Usability of Chronometric Tests and Paper-and-Pencil Tests in Children

    ERIC Educational Resources Information Center

    Quaiser-Pohl, Claudia; Neuburger, Sarah; Heil, Martin; Jansen, Petra; Schmelter, Andrea

    2014-01-01

    This article presents a reanalysis of the data of 862 second and fourth graders collected in two previous studies, focusing on the influence of method (psychometric vs. chronometric) and stimulus type on the gender difference in mental-rotation accuracy. The children had to solve mental-rotation tasks with animal pictures, letters, or cube…

  16. Role of strategies and prior exposure in mental rotation.

    PubMed

    Cherney, Isabelle D; Neff, Nicole L

    2004-06-01

    The purpose of these two studies was to examine sex differences in strategy use and the effect of prior exposure on the performance on Vandenberg and Kuse's 1978 Mental Rotation Test. A total of 152 participants completed the spatial task and self-reported their strategy use. Consistent with previous studies, men outperformed women. Strategy usage did not account for these differences, although guessing did. Previous exposure to the Mental Rotation Test, American College Test scores and frequent computer or video game play predicted performance on the test. These results suggest that prior exposure to spatial tasks may provide cues to improve participants' performance.

  17. Observations on Rotating Cavitation and Cavitation Surge from the Development of the Fastrac Engine Turbopump

    NASA Technical Reports Server (NTRS)

    Zoladz, Thomas F.

    2000-01-01

    Observations regarding rotating cavitation and cavitation surge experienced during the development of the Fastrac engine turbopump are discussed. Detailed observations acquired from the analysis of both water flow and liquid oxygen test data are offered in this paper. Scaling and general comparison of rotating cavitation between water flow and liquid oxygen testing are discussed. Complex data features linking the localized rotating cavitation mechanism of the inducer to system surge components are described in detail. Finally a description of a lumped-parameter hydraulic system model developed to better understand observed data is given.

  18. Overview of Rotating Cavitation and Cavitation Surge in the Fastrac Engine LOX Turbopump

    NASA Technical Reports Server (NTRS)

    Zoladz, Thomas; Turner, Jim (Technical Monitor)

    2001-01-01

    Observations regarding rotating cavitation and cavitation surge experienced during the development of the Fastrac 60 Klbf engine turbopump are discussed. Detailed observations from the analysis of both water flow and liquid oxygen test data are offered. Scaling and general comparison of rotating cavitation between water flow and liquid oxygen testing are discussed. Complex data features linking the localized rotating cavitation mechanism of the inducer to system surge components are described in detail. Finally a description of a simple lumped-parameter hydraulic system model developed to better understand observed data is given.

  19. Rotational coherent anti-stokes Raman spectroscopy measurements in a rotating cavity with axial throughflow of cooling air: oxygen concentration measurements.

    PubMed

    Black, J D; Long, C A

    1992-07-20

    In a rotating cavity rig, which models cooling air flow in the spaces between disks of a gas turbine compressor, the buildup of oxygen concentration after the cooling gas was changed from nitrogen to air was monitored using rotational coherent anti-Stokes Raman spectroscopy (CARS). From this information an estimate of the fraction of the throughflow entering the rotating cavity was obtained. This demonstrates that rotational CARS can be applied as a nonintrusive concentration-measurement technique in a rotating engineering test rig.

  20. Implementing a hybrid web-based curriculum for an elective medical student clerkship in a busy surgical intensive care unit (ICU): effect on test and satisfaction scores.

    PubMed

    Kumar, Avinash B; Hata, J Steven; Bayman, Emine O; Krishnan, Sundar

    2013-01-01

    To determine whether a hybrid traditional and web-based curriculum improves test scores and enrollment among senior medical students in an elective critical care rotation. Retrospective study in a surgical ICU at a major academic center. One hundred twenty-one fourth year medical students completing an elective ICU clerkship between 2007 and 2010. Pre-test and post-test during a 4-week rotation. We implemented a hybrid curriculum that involved both traditional teaching methods and a new online core curriculum that incorporating audio, video, and text using screen capture technology. The curriculum was hosted on a secure online portal called ICON (Desire2Learn Inc., Ontario, Canada). The core curriculum covered topics that were considered essential to meet the didactic objectives of the rotation. MEASUREMENTS AND EVALUATIONS: A pre-test was administered online on day 1 of the rotation. A post-test was administered on the second to last day of the rotation. Both tests were composed of 20 questions randomly chosen from a question bank of 100 questions. The tests are managed (administering, grading, and reporting) exclusively online. One hundred twenty-one medical students have successfully completed the clerkship since implementing the new curriculum. Each group of students showed an improvement in the mean post-test score by at least 17%+ to 10%. The satisfaction scores of the clerkship improved consistently from 2007 and is currently rated at 4.31 ± 0.85 (on a 5-point scale). The rotation is in the top 25(th) percentile of all clinical clerkships offered at the University of Iowa. A systematically implemented hybrid web-based critical care curriculum can improve knowledge based test scores and overall clerkship satisfaction scores in a busy surgical ICU. Copyright © 2013 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  1. Rotating rake design for unique measurement of fan-generated spinning acoustic modes

    NASA Technical Reports Server (NTRS)

    Konno, Kevin E.; Hausmann, Clifford R.

    1993-01-01

    In light of the current emphasis on noise reduction in subsonic aircraft design, NASA has been actively studying the source of and propagation of noise generated by subsonic fan engines. NASA/LeRC has developed and tested a unique method of accurately measuring these spinning acoustic modes generated by an experimental fan. This mode measuring method is based on the use of a rotating microphone rake. Testing was conducted in the 9 x 15 Low-speed Wind Tunnel. The rotating rake was tested with the Advanced Ducted Propeller (ADP) model. This memorandum discusses the design and performance of the motor/drive system for the fan-synchronized rotating acoustic rake. This novel motor/drive design approach is now being adapted for additional acoustic mode studies in new test rigs as baseline data for the future design of active noise control for subsonic fan engines. Included in this memorandum are the research requirements, motor/drive specifications, test performance results, and a description of the controls and software involved.

  2. Lift Production on Flapping and Rotary Wings at Low Reynolds Numbers

    DTIC Science & Technology

    2016-02-26

    though parameter variations were also performed. For the rotating cases, the wing was an aspect ratio 2 rectangular flat plate , and the root cutout (i.e...rectangular flat plate . 2 U (Side View) (a) 1A: Rectilinear pitch U (Side View) (b) 1B: Rectilinear surge (Top View) (Side View) (c) 2A: Rotational...0.5c φ (b) A=2 flat plate wing Figure 2: Schematic of the AVT-202 rotating wing kinematics and geometry, from Ref. 12. 3.2 Experimental Setup Rotating

  3. Rotating Rake Turbofan Duct Mode Measurement System

    NASA Technical Reports Server (NTRS)

    Sutliff, Daniel L.

    2005-01-01

    An experimental measurement system was developed and implemented by the NASA Glenn Research Center in the 1990s to measure turbofan duct acoustic modes. The system is a continuously rotating radial microphone rake that is inserted into the duct. This Rotating Rake provides a complete map of the acoustic duct modes present in a ducted fan and has been used on a variety of test articles: from a low-speed, concept test rig, to a full-scale production turbofan engine. The Rotating Rake has been critical in developing and evaluating a number of noise reduction concepts as well as providing experimental databases for verification of several aero-acoustic codes. More detailed derivation of the unique Rotating Rake equations are presented in the appendix.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilbeck, J.S.

    Ten 1/11-scale model turbine-missile-impact tests were conducted at the Naval Air Propulsion Center under the supervision of Southwest Research Institute. These tests were conducted in support of the EPRI program to assess turbine-missile effects in nuclear plant design. The objective of the tests was to determine the effects of missile spin, blade crush, and target edge conditions on the impact of turbine disk fragments on the steel casing. The burst of a modified gas-turbine rotor in a high-speed spin chamber provided three missiles with the proper rotational and translational velocities of actual steam-turbine fragments. Tests of unbladed, spinning missiles weremore » compared with previous tests of unbladed, nonspinning missiles. The total residual energy of the spinning missiles was the same as that of the nonspinning missiles launched in a piercing orientation. Tests with bladed missiles showed that for equal burst speeds, the residual energy of bladed missiles is less than that of unbladed missiles.« less

  5. Improved initial guess with semi-subpixel level accuracy in digital image correlation by feature-based method

    NASA Astrophysics Data System (ADS)

    Zhang, Yunlu; Yan, Lei; Liou, Frank

    2018-05-01

    The quality initial guess of deformation parameters in digital image correlation (DIC) has a serious impact on convergence, robustness, and efficiency of the following subpixel level searching stage. In this work, an improved feature-based initial guess (FB-IG) scheme is presented to provide initial guess for points of interest (POIs) inside a large region. Oriented FAST and Rotated BRIEF (ORB) features are semi-uniformly extracted from the region of interest (ROI) and matched to provide initial deformation information. False matched pairs are eliminated by the novel feature guided Gaussian mixture model (FG-GMM) point set registration algorithm, and nonuniform deformation parameters of the versatile reproducing kernel Hilbert space (RKHS) function are calculated simultaneously. Validations on simulated images and real-world mini tensile test verify that this scheme can robustly and accurately compute initial guesses with semi-subpixel level accuracy in cases with small or large translation, deformation, or rotation.

  6. HR 1362 - A test case for stellar dynamo theories

    NASA Technical Reports Server (NTRS)

    Strassmeier, Klaus G.; Hall, Douglas S.; Barksdale, William S.; Jusick, Anthony T.; Henry, Gregory W.

    1990-01-01

    An analysis of 11 yr of photometry of HR 1362 = EK Eri has shown a well-established photometric period of 335 days. This confirms an earlier period determination of about 310 days from 3 yr of APT data and is consistent with a new v sin i determination of 2 + or - 2 km/s. Recent Ca II H and K observations show moderately strong H and K emission lines at a flux level of log F prime (K) of about 6.5 ergs sq m/s. If the photometric period is interpreted as the rotation period, this surface flux is more than one order of magnitude larger than what can be expected from empirical activity versus rotation relationships. The spectrum and the U-B and B-V colors are consistent with a single G8 III-IV spectral classification, while the V-R and V-I values indicate a small color excess, typical of chromospherically active stars.

  7. Computer Experience and Gender Differences in Undergraduate Mental Rotation Performance.

    ERIC Educational Resources Information Center

    De Lisi, Richard; Cammarano, Diane M.

    1996-01-01

    This study surveyed undergraduates (27 men, 83 women) to investigate gender differences in mental rotation. It compared pretesting on the Vandenberg Test of Mental Rotation (VTMR) and posttesting after two sessions of computer games. Men typically scored higher on pretest VTMR. After playing a game requiring mental rotation of figures, women…

  8. Shoulder disorders in an outpatient clinic: an epidemiological study.

    PubMed

    Malavolta, Eduardo Angeli; Gracitelli, Mauro Emilio Conforto; Assunção, Jorge Henrique; Pinto, Gustavo de Mello Ribeiro; da Silveira, Arthur Zorzi Freire; Ferreira, Arnaldo Amado

    2017-01-01

    To describe shoulder disorders in patients evaluated by two shoulder and elbow surgeons. This cross-sectional study analyzed patients evaluated by two authors, excluding acute fractures and dislocations and patients with symptoms not involving the shoulder. Age and sex distribution was determined for the different diagnoses. We evaluated 1001 patients. Mean age was 51.43±15.15 years and 51.0% were female. Disorders of the rotator cuff occurred in 64.3% (41.2% tendinopathy, 11.0% partial tears and 12.2% full-thickness tears). Adhesive capsulitis occurred in 13.5% of cases and glenohumeral instability in 8.1%. Rotator cuff disorders were more common in women, with a peak between 50 and 59 years for tendinopathy and partial tears and between 60 and 69 years for full-thickness tears. Glenohumeral instability was more frequent in men, with a peak between 30 and 39 years. The most frequent diagnosis was rotator cuff tendinopathy, followed by adhesive capsulitis, full-thickness rotator cuff tears, partial rotator cuff tears and glenohumeral instability. Rotator cuff lesions were more common in women, with a peak between 60 and 69 years for full-thickness tears. Level of Evidence IV, Case Series.

  9. Rotational and fine structure of open-shell molecules in nearly degenerate electronic states

    NASA Astrophysics Data System (ADS)

    Liu, Jinjun

    2018-03-01

    An effective Hamiltonian without symmetry restriction has been developed to model the rotational and fine structure of two nearly degenerate electronic states of an open-shell molecule. In addition to the rotational Hamiltonian for an asymmetric top, this spectroscopic model includes the energy separation between the two states due to difference potential and zero-point energy difference, as well as the spin-orbit (SO), Coriolis, and electron spin-molecular rotation (SR) interactions. Hamiltonian matrices are computed using orbitally and fully symmetrized case (a) and case (b) basis sets. Intensity formulae and selection rules for rotational transitions between a pair of nearly degenerate states and a nondegenerate state have also been derived using all four basis sets. It is demonstrated using real examples of free radicals that the fine structure of a single electronic state can be simulated with either a SR tensor or a combination of SO and Coriolis constants. The related molecular constants can be determined precisely only when all interacting levels are simulated simultaneously. The present study suggests that analysis of rotational and fine structure can provide quantitative insights into vibronic interactions and related effects.

  10. Understanding the rotation of coronal holes

    NASA Astrophysics Data System (ADS)

    Wang, Y.-M.; Sheeley, N. R., Jr.

    1993-09-01

    In an earlier study we found that the rotation of coronal holes could be understood on the basis of a nearly current-free coronal field, with the holes representing open magnetic regions. In this paper we illustrate the model by focusing on the case of CH1, the rigidly rotating boot-shaped hole observed by Skylab. We show that the interaction between the polar fields and the flux associated with active regions produces distortions in the coronal field configuration and thus in the polar-hole boundaries; these distortions corotate with the perturbing nonaxisymmetric flux. In the case of CH1, positive-polarity field lines in the northern hemisphere 'collided' with like-polarity field lines fanning out from a decaying active region complex located just below the equator, producing a midlatitude corridor of open field lines rotating at the rate of the active region complex. Sheared coronal holes result when nonaxisymmetric flux is present at high latitudes, or equivalently, when the photospheric neutral line extends to high latitudes. We demonstrate how a small active region, rotating at the local photospheric rate, can drift through a rigidly rotating hole like CH1. Finally, we discuss the role of field-line reconnection in maintaining a quasi-potential coronal configuration.

  11. The Global Non-Holonomity of the Rotating Space of the Earth Affects Hafele-Keating Experiment

    NASA Astrophysics Data System (ADS)

    Rabounski, Dmitri; Borissova, Larissa

    2013-04-01

    The deviation of time registered in the ``around-the-world clocks experiment'' (Hafele J. and Keating R., Science, 14 July 1972, 166-170) is originally explained due to: 1) General Relativity (gravitation is lower at the flying airplane's altitude); 2) Special Relativity (the airplane's speed and the Earth's rotation). However as was shown in the 1940's by Schouten and then Zelmanov, if the observer cannot be moved to the rotation-free frame, the space rotation is a non-vanishing effect of General Relativity, and is due to the non-holonomity of space (the non-orthogonality of the three-space to the lines of time). This is the case of Hafele-Keating experiment (the Earth's rotation cannot be stopped). We thus constructed the metric of the real space of the Earth which bears the gravitational field and rotation. We then proved that this metric satisfies Einstein's equations. Finally, an exact formula is deduced for Hafele-Keating experiment. Despite a hundred nanoseconds of the time correction, and the use of the GPS navigation, the obtained result is useful in the case where is no the GPS connexion, in a long-term submarine travel for instance.

  12. Validation of theoretical models of intrinsic torque in DIII-D

    NASA Astrophysics Data System (ADS)

    Grierson, B. A.; Wang, W. X.; Battaglia, D. J.; Chrystal, C.; Solomon, W. M.; Degrassie, J. S.; Staebler, G. M.; Boedo, J. A.

    2016-10-01

    Plasma rotation experiments in DIII-D are validating models of main-ion intrinsic rotation by testing Reynolds stress induced toroidal flow in the plasma core and intrinsic rotation induced by ion orbit losses in the plasma edge. In the core of dominantly electron heated plasmas with Te=Ti, the main-ion intrinsic toroidal rotation undergoes a reversal that correlates with the critical gradient for ITG turbulence. Residual stress arising from zonal-flow ExB shear and turbulence intensity gradient produce residual stress and counter-current intrinsic torque, which is balanced by momentum diffusion, creating the hollow profile. Quantitative agreement is obtained for the first time between the measured main-ion toroidal rotation and the rotation profile predicted by nonlinear GTS gyrokinetic simulations. At the plasma boundary, new main-ion CER measurements show a co-current rotation layer and this is tested against ion orbit loss models as the source of bulk plasma rotation. Work supported by the US Department of Energy under DE-AC02-09CH11466 and DE-FC02-04ER54698.

  13. Beyond Genetics in Mental Rotation Test Performance: The Power of Effort Attribution

    ERIC Educational Resources Information Center

    Moe, Angelica; Pazzaglia, Francesca

    2010-01-01

    This study compares the effects on Mental Rotation Test (MRT) performance of instructions that stress the importance of (a) personal effort, and (b) genetically driven ability. A total of 120 high-school students were assigned to three groups, and administered two sub-tests of the MRT. Between the first and second sub-tests, the groups received…

  14. Autocollimation system for measuring angular deformations with reflector designed by quaternionic method

    NASA Astrophysics Data System (ADS)

    Hoang, Phong V.; Konyakhin, Igor A.

    2017-06-01

    Autocollimators are widely used for angular measurements in instrument-making and the manufacture of elements of optical systems (wedges, prisms, plane-parallel plates) to check their shape parameters (rectilinearity, parallelism and planarity) and retrieve their optical parameters (curvature radii, measure and test their flange focusing). Autocollimator efficiency is due to the high sensitivity of the autocollimation method to minor rotations of the reflecting control element or the controlled surface itself. We consider using quaternions to optimize reflector parameters during autocollimation measurements as compared to the matrix technique. Mathematical model studies have demonstrated that the orthogonal positioning of the two basic unchanged directions of the tetrahedral reflector of the autocollimator is optimal by the criterion of reducing measurement errors where the axis of actual rotation is in a bisecting position towards them. Computer results are presented of running quaternion models that yielded conditions for diminishing measurement errors provided apriori information is available on the position of rotation axis. A practical technique is considered for synthesizing the parameters of the tetrahedral reflector that employs the newly-retrieved relationships. Following the relationships found between the angles of the tetrahedral reflector and the angles of the parameters of its initial orientation, an applied technique was developed to synthesize the control element for autocollimation measurements in case apriori information is available on the axis of actual rotation during monitoring measurements of shaft or pipeline deformation.

  15. Hydrodynamic interactions between a self-rotation rotator and passive particles

    NASA Astrophysics Data System (ADS)

    Ouyang, Zhenyu; Lin, Jian-Zhong; Ku, Xiaoke

    2017-10-01

    In this paper, we numerically investigate the hydrodynamic interaction between a self-rotation rotator and passive particles in a two-dimensional confined cavity at two typical Reynolds numbers according to the different flow features. Both the fluid-particle interaction and particle-particle interaction through fluid media are taken into consideration. The results show that from the case of a rotator and one passive particle to the case of a rotator and two passive particles, the system becomes much more complex because the relative displacement between the rotator and the passive particles and the velocity of passive particles are strongly dependent on the Reynolds number and the initial position of passive particles. For the system of two particles, the passive particle gradually departs from the rotator although its relative displacement to the rotator exhibits a periodic oscillation at the lower Reynolds number. Furthermore, the relative distance between the two particles and the rotator's rotational frequency are responsible for the oscillation amplitude and frequency of the passive particle's velocity. For the system of three particles, the passive particle's velocities exhibit a superposition of a large amplitude oscillation and a small amplitude oscillation at the lower Reynolds number, and the large amplitude oscillation will disappear at the higher Reynolds number. The change of the included angle of the two passive particles is dependent on the initial positions of the passive particles at the lower Reynolds number, whereas the included angle of the two passive particles finally approaches a fixed value at the higher Reynolds number. It is interesting that the two passive particles periodically approach and depart from each other when the included angle is not equal to π, while all the three particles (including the rotator) keep the positions in a straight line when the included angle is equal to π because the interference between two passive particles disappears. In addition, the passive particle rotates not only around the rotator but also around its own axis, and the rotation speed of the former is far greater than that of the latter.

  16. A novel method for the photographic recovery of fingermark impressions from ammunition cases using digital imaging.

    PubMed

    Porter, Glenn; Ebeyan, Robert; Crumlish, Charles; Renshaw, Adrian

    2015-03-01

    The photographic preservation of fingermark impression evidence found on ammunition cases remains problematic due to the cylindrical shape of the deposition substrate preventing complete capture of the impression in a single image. A novel method was developed for the photographic recovery of fingermarks from curved surfaces using digital imaging. The process involves the digital construction of a complete impression image made from several different images captured from multiple camera perspectives. Fingermark impressions deposited onto 9-mm and 0.22-caliber brass cartridge cases and a plastic 12-gauge shotgun shell were tested using various image parameters, including digital stitching method, number of images per 360° rotation of shell, image cropping, and overlap. The results suggest that this method may be successfully used to recover fingermark impression evidence from the surfaces of ammunition cases or other similar cylindrical surfaces. © 2014 American Academy of Forensic Sciences.

  17. Slit scan radiographic system for intermediate size rocket motors

    NASA Astrophysics Data System (ADS)

    Bernardi, Richard T.; Waters, David D.

    1992-12-01

    The development of slit-scan radiography capability for the NASA Advanced Computed Tomography Inspection System (ACTIS) computed tomography (CT) scanner at MSFC is discussed. This allows for tangential case interface (bondline) inspection at 2 MeV of intermediate-size rocket motors like the Hawk. Motorized mounting fixture hardware was designed, fabricated, installed, and tested on ACTIS. The ACTIS linear array of x-ray detectors was aligned parallel to the tangent line of a horizontal Hawk motor case. A 5 mm thick x-ray fan beam was used. Slit-scan images were produced with continuous rotation of a horizontal Hawk motor. Image features along Hawk motor case interfaces were indicated. A motorized exit cone fixture for ACTIS slit-scan inspection was also provided. The results of this SBIR have shown that slit scanning is an alternative imaging technique for case interface inspection. More data is required to qualify the technique for bondline inspection.

  18. Rotational and peak torque stiffness of rugby shoes.

    PubMed

    Ballal, Moez S; Usuelli, Federico Giuseppe; Montrasio, Umberto Alfieri; Molloy, Andy; La Barbera, Luigi; Villa, Tomaso; Banfi, Giuseppe

    2014-09-01

    Sports people always strive to avoid injury. Sports shoe designs in many sports have been shown to affect traction and injury rates. The aim of this study is to demonstrate the differing stiffness and torque in rugby boots that are designed for the same effect. Five different types of rugby shoes commonly worn by scrum forwards were laboratory tested for rotational stiffness and peak torque on a natural playing surface generating force patterns that would be consistent with a rugby scrum. The overall internal rotation peak torque was 57.75±6.26 Nm while that of external rotation was 56.55±4.36 Nm. The Peak internal and external rotational stiffness were 0.696±0.1 and 0.708±0.06 Nm/deg respectively. Our results, when compared to rotational stiffness and peak torques of football shoes published in the literature, show that shoes worn by rugby players exert higher rotational and peak torque stiffness compared to football shoes when tested on the same natural surfaces. There was significant difference between the tested rugby shoes brands. In our opinion, to maximize potential performance and lower the potential of non-contact injury, care should be taken in choosing boots with stiffness appropriate to the players main playing role. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Isolated Subscapularis Repair in Irreparable Posterosuperior Massive Rotator Cuff Tears Involving the Subscapularis Tendon.

    PubMed

    Kim, Sung-Jae; Choi, Yun-Rak; Jung, Min; Lee, Won-Yong; Chun, Yong-Min

    2017-05-01

    No previous study has examined whether isolated subscapularis tendon repair in irreparable posterosuperior massive rotator tears involving the subscapularis tendon in relatively young patients without arthritis can yield satisfactory outcomes. We hypothesized that this procedure would produce favorable outcomes in patients who might otherwise be candidates for reverse arthroplasty. Case series; Level of evidence, 4. This retrospective study included 24 patients in their 50s and 60s, without shoulder arthritis, who underwent arthroscopic isolated subscapularis repair for an irreparable massive rotator cuff tear involving the subscapularis tendon. Preoperative and postoperative visual analog scale (VAS) pain scores, subjective shoulder values (SSVs), University of California at Los Angeles (UCLA) shoulder scores, American Shoulder and Elbow Surgeons (ASES) scores, subscapularis strength (modified bell-press test; maximum of 5), and shoulder active range of motion (ROM) were assessed. Postoperative magnetic resonance arthrography (MRA) was performed 6 months postoperatively to assess structural integrity of the repaired subscapularis. At a mean 34.8 months (range, 24-49 months) of follow-up, VAS pain scores (improved from 7.1 to 2.5), SSVs (33.3 to 75.2), ASES scores (35.9 to 76.0), UCLA shoulder scores (11.6 to 24.8), subscapularis strength, and ROM were significantly improved compared with preoperative measurements ( P < .001). Subscapularis muscle strength improved from 3.7 to 4.2 ( P < .001). For active ROM, forward flexion and internal rotation improved significantly ( P < .001); however, external rotation exhibited no significant improvement. Follow-up MRA was performed in 22 patients (92%) and showed retear of the repaired subscapularis in 6 (27% of the 22). Isolated repair of the subscapularis tendon in irreparable massive rotator cuff tears involving the subscapularis tendon yielded satisfactory short-term outcomes and structural integrity in patients in their 50s and 60s without arthritis. If patients with irreparable massive rotator cuff tears involving the subscapularis tendon are relatively young or have minimal concomitant arthritis, this repair can be worthwhile.

  20. Sex Differences in Spatial Performance as Related to Cerebral Lateralization.

    ERIC Educational Resources Information Center

    Freedman, Rita Jackaway; And Others

    The extent to which sex differences on a mental rotation test were related to ocular dominance, handedness, and familial handedness was explored. The Vandenberg revision of the Shepard-Metzlar mental rotation test was administered to 206 college students. The test consisted of 20 criterion figures, each followed by two correct and two incorrect…

  1. Psychometric Properties of the Revised Purdue Spatial Visualization Tests: Visualization of Rotations (The Revised PSVT-R)

    ERIC Educational Resources Information Center

    Yoon, So Yoon

    2011-01-01

    Working under classical test theory (CTT) and item response theory (IRT) frameworks, this study investigated psychometric properties of the Revised Purdue Spatial Visualization Tests: Visualization of Rotations (Revised PSVT:R). The original version, the PSVT:R was designed by Guay (1976) to measure spatial visualization ability in…

  2. Autogenic-feedback training as a treatment for airsickness in high-performance military aircraft: Two case studies

    NASA Technical Reports Server (NTRS)

    Cowings, Patricia S.; Toscano, William B.; Miller, Neal E.; Reynoso, Samuel

    1994-01-01

    The purpose of this paper is to present a detailed description of the physiological and performance responses of two military pilots undergoing a treatment for motion sickness. The treatment used, Autogenic-Feedback Training (AFT), is an operant conditioning procedure where subjects are taught to control several of their autonomic responses and thereby suppress their motion sickness symptoms. Two male, active duty military pilots (U.S. Navy and U. S. Marine Corps), ages 30 and 35, were each given twelve 30-minute training sessions. The primary criterion for success of training was the subject's ability to tolerate rotating chair motion sickness tests for progressively longer periods of time and at higher rotational velocities. A standardized diagnostic scale was used during motion sickness to assess changes in the subject's perceived malaise. Physiological data were obtained from one pilot during tactical maneuvers in an F-18 aircraft after completion of his training. A significant increase in tolerance to laboratory-induced motion sickness tests and a reduction in autonomic nervous system (ANS) response variability was observed for both subjects after training. Both pilots were successful in applying AFT for controlling their airsickness during subsequent qualification tests on F-18 and T-38 aircraft and were returned to active duty flight status.

  3. Description of the Posterolateral Rotatory Drawer Maneuver for the Identification of Posterolateral Corner Injury

    PubMed Central

    Angelini, Fábio Janson; Bonadio, Marcelo Batista; Helito, Camilo Partezani; da Mota e Albuquerque, Roberto Freire; Pécora, José Ricardo; Camanho, Gilberto Luis

    2014-01-01

    Injury to the posterolateral corner (PLC) is difficult to diagnose; most lesions of this type are included within the context of complex knee injuries. Study of the posterolateral complex is growing in importance because of the complex instability generated by these injuries. Although various physical examination tests are described for the diagnosis of PLC lesions, in 72% of cases these lesions are not identified at their initial presentation, which shows the difficulty in both performing these tests and interpreting the results. The maneuver described in this report is performed by executing external rotation of the leg. With the thumb of the proximally positioned hand, the examiner evaluates the positioning of the lateral tibial plateau in relation to the femoral condyle. With this maneuver, in lesions of the PLC and particularly lesions of its external rotation–restricting structures, we observe external rotation of the tibia and posterior subluxation of the lateral tibial plateau that cause the anterior edge of the tibial plateau to be posteriorized in relation to the anterior edge of the lateral femoral condyle. The idea behind this maneuver is not to eliminate the use of other tests but, rather, to add it to a diagnostic arsenal that still has interpretation flaws. PMID:24904781

  4. Abnormal origins of the long head of the biceps tendon can lead to rotator cuff pathology: a report of two cases.

    PubMed

    Zhang, Alan L; Gates, Cameron H; Link, Thomas M; Ma, C Benjamin

    2014-11-01

    Previous case reports have highlighted various anomalous origins of the long head of the biceps tendon (LHBT) that do not originate from the superior glenoid labrum or supraglenoid tubercle. Yet, these cases were all reported as incidental findings and were not thought to cause any significant shoulder pathology. We present the magnetic resonance (MR) imaging and clinical treatment of two cases where aberrant intra-articular origins of the long head of the biceps tendon from the anterior edge of the supraspinatus tendon may have contributed to symptomatic rotator cuff pathology. Arthroscopy confirmed MR findings of partial articular-sided supraspinatus lesions in close proximity to the anomalous origins and treatment with tenodesis of the LHBT successfully relieved symptoms. Although rare occurrences with subtle and potentially misleading imaging findings, it is important to be aware of aberrant origins of the LHBT that may contribute to concomitant rotator cuff pathology.

  5. Heat Exchanger Design and Testing for a 6-Inch Rotating Detonation Engine

    DTIC Science & Technology

    2013-03-01

    Engine Research Facility HHV Higher heating value LHV Lower heating value PDE Pulsed detonation engine RDE Rotating detonation engine RTD...the combustion community are pulse detonation engines ( PDEs ) and rotating detonation engines (RDEs). 1.1 Differences between Pulsed and Rotating ...steadier than that of a PDE (2, 3). (2) (3) Figure 1. Unrolled rotating detonation wave from high-speed video (4) Another difference that

  6. Comparison of range of motion tests with throwing kinematics in elite team handball players.

    PubMed

    van den Tillaar, Roland

    2016-10-01

    The aim of this study was to compare the active and passive range of motion (ROM) of the glenohumeral external rotation with the maximal external rotation and throwing performance during different throws with different wind-up techniques in elite team handball players. Twenty-two elite team handball players participated in the study in which the maximal ball release velocity and maximal external rotation during standing, with run-up and jump throws with two types of wind-ups were measured together with the maximal active and passive glenohumeral ROM of the external rotation, lying supine on a bench. Higher maximal external rotation was found during the throws with the whip-like wind-up in comparison to circular-like wind-up throws together with a lower external rotation during the active ROM test. No correlations were found between the ROM of the external rotation with the maximal ball release velocity and the maximal external rotation measured during the throws. It was concluded that ROM of the external rotation measured on the bench does not give any information about the maximal throwing performance or the external rotation angle during throwing and therefore cannot be used to identify potential fast throwers or injuries in elite team handball players.

  7. Compensations for increased rotational inertia during human cutting turns.

    PubMed

    Qiao, Mu; Brown, Brian; Jindrich, Devin L

    2014-02-01

    Locomotion in a complex environment is often not steady state, but unsteady locomotion (stability and maneuverability) is not well understood. We investigated the strategies used by humans to perform sidestep cutting turns when running. Previous studies have argued that because humans have small yaw rotational moments of inertia relative to body mass, deceleratory forces in the initial velocity direction that occur during the turning step, or 'braking' forces, could function to prevent body over-rotation during turns. We tested this hypothesis by increasing body rotational inertia and testing whether braking forces during stance decreased. We recorded ground reaction force and body kinematics from seven participants performing 45 deg sidestep cutting turns and straight running at five levels of body rotational inertia, with increases up to fourfold. Contrary to our prediction, braking forces remained consistent at different rotational inertias, facilitated by anticipatory changes to body rotational speed. Increasing inertia revealed that the opposing effects of several turning parameters, including rotation due to symmetrical anterior-posterior forces, result in a system that can compensate for fourfold changes in rotational inertia with less than 50% changes to rotational velocity. These results suggest that in submaximal effort turning, legged systems may be robust to changes in morphological parameters, and that compensations can involve relatively minor adjustments between steps to change initial stance conditions.

  8. Compensations for increased rotational inertia during human cutting turns

    PubMed Central

    Qiao, Mu; Brown, Brian; Jindrich, Devin L.

    2014-01-01

    Locomotion in a complex environment is often not steady state, but unsteady locomotion (stability and maneuverability) is not well understood. We investigated the strategies used by humans to perform sidestep cutting turns when running. Previous studies have argued that because humans have small yaw rotational moments of inertia relative to body mass, deceleratory forces in the initial velocity direction that occur during the turning step, or ‘braking’ forces, could function to prevent body over-rotation during turns. We tested this hypothesis by increasing body rotational inertia and testing whether braking forces during stance decreased. We recorded ground reaction force and body kinematics from seven participants performing 45 deg sidestep cutting turns and straight running at five levels of body rotational inertia, with increases up to fourfold. Contrary to our prediction, braking forces remained consistent at different rotational inertias, facilitated by anticipatory changes to body rotational speed. Increasing inertia revealed that the opposing effects of several turning parameters, including rotation due to symmetrical anterior–posterior forces, result in a system that can compensate for fourfold changes in rotational inertia with less than 50% changes to rotational velocity. These results suggest that in submaximal effort turning, legged systems may be robust to changes in morphological parameters, and that compensations can involve relatively minor adjustments between steps to change initial stance conditions. PMID:24115061

  9. In vitro evaluation of translating and rotating plates using a robot testing system under follower load.

    PubMed

    Yan, Y; Bell, K M; Hartman, R A; Hu, J; Wang, W; Kang, J D; Lee, J Y

    2017-01-01

    Various modifications to standard "rigid" anterior cervical plate designs (constrained plate) have been developed that allow for some degree of axial translation and/or rotation of the plate (semi-constrained plate)-theoretically promoting proper load sharing with the graft and improved fusion rates. However, previous studies about rigid and dynamic plates have not examined the influence of simulated muscle loading. The objective of this study was to compare rigid, translating, and rotating plates for single-level corpectomy procedures using a robot testing system with follower load. In-vitro biomechanical test. N = 15 fresh-frozen human (C3-7) cervical specimens were biomechanically tested. The follower load was applied to the specimens at the neutral position from 0 to 100 N. Specimens were randomized into a rigid plate group, a translating plate group and a rotating plate group and then tested in flexion, extension, lateral bending and axial rotation to a pure moment target of 2.0 Nm under 100N of follower load. Range of motion, load sharing, and adjacent level effects were analyzed using a repeated measures analysis of variance (ANOVA). No significant differences were observed between the translating plate and the rigid plate on load sharing at neutral position and C4-6 ROM, but the translating plate was able to maintain load through the graft at a desired level during flexion. The rotating plate shared less load than rigid and translating plates in the neutral position, but cannot maintain the graft load during flexion. This study demonstrated that, in the presence of simulated muscle loading (follower load), the translating plate demonstrated superior performance for load sharing compared to the rigid and rotating plates.

  10. Occupant Motion Sensors : Development and Testing of Piezoresistive Mouthpiece Rotational Accelerometer

    DOT National Transportation Integrated Search

    1973-07-01

    A miniature piezoresistive mouthpiece rotational accelerometer has been developed to measure the angular acceleration of a head during a simulated vehicle crash. Corrections have been electronically applied to the rotational accelerometer to reduce i...

  11. Crankshaft motion in a highly congested bis(triarylmethyl)peroxide.

    PubMed

    Khuong, Tinh-Alfredo V; Zepeda, Gerardo; Sanrame, Carlos N; Dang, Hung; Bartberger, Michael D; Houk, K N; Garcia-Garibay, Miguel A

    2004-11-17

    Crankshaft motion has been proposed in the solid state for molecular fragments consisting of three or more rotors linked by single bonds, whereby the two terminal rotors are static and the internal rotors experience circular motion. Bis-[tri-(3,5-di-tert-butyl)phenylmethyl]-peroxide 2 was tested as a model in search of crankshaft motion at the molecular level. In the case of peroxide 2, the bulky trityl groups may be viewed as the external static rotors, while the two peroxide oxygens can undergo the sought after internal rotation. Evidence for this process in the case of peroxide 2 was obtained from conformational dynamics determined by variable-temperature (13)C and (1)H NMR between 190 and 375 K in toluene-d(8). Detailed spectral assignments for the interpretation of two coalescence processes were based on a correlation between NMR spectra obtained in solution at low temperature, in the solid state by (13)C CPMAS NMR, and by GIAO calculations based on a B3LYP/6-31G structure of 2 obtained from its X-ray coordinates as the input. Evidence supporting crankshaft rotation rather than slippage of the trityl groups was obtained from molecular mechanics calculations.

  12. Pool boiling from rotating and stationary spheres in liquid nitrogen

    NASA Technical Reports Server (NTRS)

    Cuan, Winston M.; Schwartz, Sidney H.

    1988-01-01

    Results are presented for a preliminary experiment involving saturated pool boiling at 1 atm from rotating 2 and 3 in. diameter spheres which were immersed in liquid nitrogen (LN2). Additional results are presented for a stationary, 2 inch diameter sphere, quenched in LN2, which were obtained utilizing a more versatile and complete experimental apparatus that will eventually be used for additional rotating sphere experiments. The speed for the rotational tests was varied from 0 to 10,000 rpm. The stationary experiments parametrically varied pressure and subcooling levels from 0 to 600 psig and from 0 to 50 F, respectively. During the rotational tests, a high speed photographic analysis was undertaken to measure the thickness of the vapor film surrounding the sphere. The average Nusselt number over the cooling period was plotted against the rotational Reynolds number. Stationary sphere results included local boiling heat transfer coefficients at different latitudinal locations, for various pressure and subcooling levels.

  13. High heat-flux self-rotating plasma-facing component: Concept and loading test in TEXTOR

    NASA Astrophysics Data System (ADS)

    Terra, A.; Sergienko, G.; Hubeny, M.; Huber, A.; Mertens, Ph.; Philipps, V.; The Textor Team

    2015-08-01

    This contribution reports on the concept of a circular self-rotating and temperature self-stabilising plasma-facing component (PFC), and test of a related prototype in TEXTOR tokamak. This PFC uses the Lorentz force induced by plasma current and magnet field (J × B) to create a torque applied on metallic discs which produce a rotational movement. Additional thermionic current, present at high operation temperatures, brings additional temperature stabilisation ability. This self-rotating disk limiter was exposed to plasma in the TEXTOR tokamak under different radial positions to vary the heat flux. This disk structure shows the interesting ability to stabilise its maximum temperature through the fact that the self-induced rotation is modulated by the thermal emission current. It was observed that the rotation speed increased following both the current collected by the limiter, and the temperature of the tungsten disks.

  14. Some current research in rotating-disc systems.

    PubMed

    Owen, J M; Wilson, M

    2001-05-01

    Rotating-disc systems are used to model the flow and heat transfer that occurs inside the cooling-air systems of gas-turbine engines. In this paper, recent computational and experimental research in three systems is discussed: rotor-stator systems, rotating cavities with superposed flow and buoyancy-induced flow in a rotating cavity. Discussion of the first two systems concentrates respectively on pre-swirl systems and rotating cavities with a peripheral inflow and outflow of cooling air. Buoyancy-induced flow in a rotating cavity is one of the most difficult problems facing computationalists and experimentalists, and there are similarities between the circulation in the Earth's atmosphere and the flow inside gas-turbine rotors. For this case, results are presented for heat transfer in sealed annuli and in rotating cavities with an axial throughflow of cooling air.

  15. Response to “Comment on ‘General rotating quantum vortex filaments in the low-temperature Svistunov model of the local induction approximation’” [Phys. Fluids 26, 119101 (2014)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Gorder, Robert A., E-mail: rav@knights.ucf.edu

    2014-11-15

    In R. A. Van Gorder, “General rotating quantum vortex filaments in the low-temperature Svistunov model of the local induction approximation,” Phys. Fluids 26, 065105 (2014) I discussed properties of generalized vortex filaments exhibiting purely rotational motion under the low-temperature Svistunov model of the local induction approximation. Such solutions are stationary in terms of translational motion. In the Comment [N. Hietala, “Comment on ‘General rotating quantum vortex filaments in the low-temperature Svistunov model of the local induction approximation’ [Phys. Fluids 26, 065105 (2014)],” Phys. Fluids 26, 119101 (2014)], the author criticizes my paper for not including translational motion (although it wasmore » clearly stated that the filament motion was assumed rotational). As it turns out, if one is interested in studying the geometric structure of solutions (which was the point of my paper), one obtains the needed qualitative results on the structure of such solutions by studying the purely rotational case. Nevertheless, in this Response I shall discuss the vortex filaments that have both rotational and translational motions. I then briefly discuss why one might want to study such generalized rotating filament solutions, in contrast to simple the standard helical or planar examples (which are really special cases). I also discuss how one can study the time evolution of filaments which exhibit more complicated dynamics than pure translation and rotation. Doing this, one can study non-stationary solutions which initially appear purely rotational and gradually display other dynamics as the filaments evolve.« less

  16. Characterisation of parallel misalignment in rotating machines by means of the modulated signal of incremental encoders

    NASA Astrophysics Data System (ADS)

    Meroño Pérez, P. A.; Gómez de León, F. C.; Zaghar, L.

    2014-10-01

    There are many defects in rotating machines which, when analysed by means of the Fourier spectrum of transversal vibration, show several harmonics of the rotational speed, more specifically the first and the second, although higher harmonics may also be present. Misalignments, looseness, the breakage of fastening screws, broken mechanical seals, are just some of the problems. Nevertheless, the effects of some of these defects differ when the angular vibration is measured using an incremental rotating encoder, which offers an additional aid for diagnosing the problem. In this paper, we analyse the characteristics measurements made of the angular vibrations by means of an incremental rotating encoder, in cases of a parallel misalignment between coupled shafts. The spectral frequency lines obtained from the pulse signal generated by the encoder show a series of equidistant lateral bands around the main frequency, which reveals the existence of a specific angular vibration and, therefore, the frequency modulation produced. The phenomenon is explained using the Bessel functions, which establishes a relationship between the frequency spectrum of the angular vibration and the modulated signal from the encoder. The spectral analysis of the pulsating signal of the encoder displays a set of main lines, which are multiples of the main frequency of the pulses, and a set of sidebands around each one of these spectral lines. The method proposed is verified by means of measurements made on laboratory test benches and on industrial equipment, comparing and analysing the angular vibrations, which are measured using a laser interferometer and incremental encoders.

  17. Design & fabrication of two seated aircraft with an advanced rotating leading edge wing

    NASA Astrophysics Data System (ADS)

    Al Ahmari, Saeed Abdullah Saeed

    The title of this thesis is "Design & Fabrication of two Seated Aircraft with an Advanced Rotating Leading Edge Wing", this gives almost a good description of the work has been done. In this research, the moving surface boundary-layer control (MSBC) concept was investigated and implemented. An experimental model was constructed and tested in wind tunnel to determine the aerodynamic characteristics using the leading edge moving surface of modified semi-symmetric airfoil NACA1214. The moving surface is provided by a high speed rotating cylinder, which replaces the leading edge of the airfoil. The angle of attack, the cylinder surfaces velocity ratio Uc/U, and the flap deflection angle effects on the lift and drag coefficients and the stall angle of attack were investigated. This new technology was applied to a 2-seat light-sport aircraft that is designed and built in the Aerospace Engineering Department at KFUPM. The project team is led by the aerospace department chairman Dr. Ahmed Z. AL-Garni and Dr. Wael G. Abdelrahman and includes graduate and under graduate student. The wing was modified to include a rotating cylinder along the leading edge of the flap portion. This produced very promising results such as the increase of the maximum lift coefficient at Uc/U=3 by 82% when flaps up and 111% when flaps down at 40° and stall was delayed by 8degrees in both cases. The laboratory results also showed that the effective range of the leading-edge rotating cylinder is at low angles of attack which reduce the need for higher angles of attack for STOL aircraft.

  18. Process Parameters Optimization in Single Point Incremental Forming

    NASA Astrophysics Data System (ADS)

    Gulati, Vishal; Aryal, Ashmin; Katyal, Puneet; Goswami, Amitesh

    2016-04-01

    This work aims to optimize the formability and surface roughness of parts formed by the single-point incremental forming process for an Aluminium-6063 alloy. The tests are based on Taguchi's L18 orthogonal array selected on the basis of DOF. The tests have been carried out on vertical machining center (DMC70V); using CAD/CAM software (SolidWorks V5/MasterCAM). Two levels of tool radius, three levels of sheet thickness, step size, tool rotational speed, feed rate and lubrication have been considered as the input process parameters. Wall angle and surface roughness have been considered process responses. The influential process parameters for the formability and surface roughness have been identified with the help of statistical tool (response table, main effect plot and ANOVA). The parameter that has the utmost influence on formability and surface roughness is lubrication. In the case of formability, lubrication followed by the tool rotational speed, feed rate, sheet thickness, step size and tool radius have the influence in descending order. Whereas in surface roughness, lubrication followed by feed rate, step size, tool radius, sheet thickness and tool rotational speed have the influence in descending order. The predicted optimal values for the wall angle and surface roughness are found to be 88.29° and 1.03225 µm. The confirmation experiments were conducted thrice and the value of wall angle and surface roughness were found to be 85.76° and 1.15 µm respectively.

  19. Large Eddy Simulation of turbulence induced secondary flows in stationary and rotating straight square ducts

    NASA Astrophysics Data System (ADS)

    Sudjai, W.; Juntasaro, V.; Juttijudata, V.

    2018-01-01

    The accuracy of predicting turbulence induced secondary flows is crucially important in many industrial applications such as turbine blade internal cooling passages in a gas turbine and fuel rod bundles in a nuclear reactor. A straight square duct is popularly used to reveal the characteristic of turbulence induced secondary flows which consists of two counter rotating vortices distributed in each corner of the duct. For a rotating duct, the flow can be divided into the pressure side and the suction side. The turbulence induced secondary flows are converted to the Coriolis force driven two large circulations with a pair of additional vortices on the pressure wall due to the rotational effect. In this paper, the Large Eddy Simulation (LES) of turbulence induced secondary flows in a straight square duct is performed using the ANSYS FLUENT CFD software. A dynamic kinetic energy subgrid-scale model is used to describe the three-dimensional incompressible turbulent flows in the stationary and the rotating straight square ducts. The Reynolds number based on the friction velocity and the hydraulic diameter is 300 with the various rotation numbers for the rotating cases. The flow is assumed fully developed by imposing the constant pressure gradient in the streamwise direction. For the rotating cases, the rotational axis is placed perpendicular to the streamwise direction. The simulation results on the secondary flows and the turbulent statistics are found to be in good agreement with the available Direct Numerical Simulation (DNS) data. Finally, the details of the Coriolis effects are discussed.

  20. Axial Plane Deformity of the Shoulder in Adolescent Idiopathic Scoliosis.

    PubMed

    Menon, Venugopal K; Tahasildar, Naveen; Pillay, Haroon M; M, Anbuselvam

    2017-05-01

    Prospective observational study. To study axial plane deformation of the shoulder in adolescent idiopathic scoliosis (AIS) and try to correlate it with curve type and surgical correction. It is established that AIS is a 3-dimensional deformity. The rib hump is the most common manifestation of axial plane deformations; the least common manifestation seems to be upper trunk and shoulder rotation, which has been hitherto undescribed. Fourteen consecutive, operated cases of AIS were analyzed prospectively. Preoperative and postoperative x-rays of the spine and clinical photographs were studied. Clinical photographs (top view) were taken with patients in the sitting position, to show shoulder level in relation to the axis of the head and pelvis. Chest computed tomography scans were also studied to determine the direction of apical vertebra and trunk torsion. All 14 patients in this series had their right shoulders anteriorly rotated preoperatively (anticlockwise). The direction of rotation seemed unrelated to the curve type and shoulder elevation, although most had rib humps on the right. This shoulder rotation was corrected postoperatively by routine maneuvers done for scoliosis correction. Minor residual rotation was seen in 6 patients who also had minimal persisting rib hump. In 1 case the axial plane rotation worsened, although the shoulder level and trunk symmetry improved significantly. The apical vertebral rotation on computed tomography had little bearing on the direction of shoulder rotation. Axial plane rotation of the shoulder is a hitherto un-described dimension of AIS deformity complex. Much of it corrects spontaneously with correction of the thoracic spinal deformity.

  1. Quantifying entanglement of rotor chains using basis truncation: Application to dipolar endofullerene peapods.

    PubMed

    Halverson, Tom; Iouchtchenko, Dmitri; Roy, Pierre-Nicholas

    2018-02-21

    We propose a variational approach for the calculation of the quantum entanglement entropy of assemblies of rotating dipolar molecules. A basis truncation scheme based on the total angular momentum quantum number is proposed. The method is tested on hydrogen fluoride (HF) molecules confined in C 60 fullerene cages themselves trapped in a nanotube to form a carbon peapod. The rotational degrees of freedom of the HF molecules and dipolar interactions between neighboring molecules are considered in our model Hamiltonian. Both screened and unscreened dipoles are simulated and results are obtained for the ground state and one excited state that is expected to be accessible via a far-infrared collective excitation. The effect of basis truncation on energetic and entanglement properties is examined and discussed in terms of size extensivity. It is empirically found that for unscreened dipoles, a total angular momentum cutoff that increases linearly with the number of rotors is required in order to obtain proper system size scaling of the chemical potential and entanglement entropy. Recent experiments [A. Krachmalnicoff et al., Nat. Chem. 8, 953 (2016)] suggest substantial screening of the HF dipole moment, so much smaller basis sets are required to obtain converged results in this realistic case. Static correlation functions are also computed and are shown to decay much quicker in the case of screened dipoles. Our variational results are also used to test the accuracy of perturbative and pairwise ansatz treatments.

  2. Probable Rotation States of Rocket Bodies in Low Earth Orbit

    NASA Technical Reports Server (NTRS)

    Ojakangas, Gregory W.; Anz-Meador, P.; Cowardin, H.

    2012-01-01

    In order for Active Debris Removal to be accomplished, it is critically important to understand the probable rotation states of orbiting, spent rocket bodies. As compared to the question of characterizing small unresolved debris, in this problem there are several advantages: (1) objects are of known size, mass, shape and color, (2) they have typically been in orbit for a known period of time, (3) they are large enough that resolved images may be obtainable for verification of predicted orientation, and (4) the dynamical problem is simplified to first order by largely cylindrical symmetry. It is also nearly certain for realistic rocket bodies that internal friction is appreciable in the case where residual liquid or, to a lesser degree, unconsolidated solid fuels exist. Equations of motion have been developed for this problem in which internal friction as well as torques due to solar radiation, magnetic induction, and gravitational gradient are included. In the case of pure cylindrical symmetry, the results are compared to analytical predictions patterned after the standard approach for analysis of symmetrical tops. This is possible because solar radiation and gravitational torques may be treated as conservative. Agreement between results of both methods ensures their mutual validity. For monotone symmetric cylinders, solar radiation torque vanishes if the center of mass resides at the geometric center of the object. Results indicate that in the absence of solar radiation effects, rotation states tend toward an equilibrium configuration in which rotation is about the axis of maximum inertia, with the axis of minimum inertia directed toward the center of the earth. Solar radiation torque introduces a modification to this orientation. The equilibrium state is asymptotically approached within a characteristic timescale given by a simple ratio of relevant characterizing parameters for the body in question. Light curves are simulated for the expected asymptotic final rotation states of model objects, and these are compared to data derived from physical models of the same objects, tested in the Optical Measurements Center at JSC. Comparison to relevant light curves from actual orbiting rocket bodies are also performed, and diagnostic features of such curves are examined.

  3. Are Strong Zonal Winds in Giant Planets Caused by Density-Stratification?

    NASA Astrophysics Data System (ADS)

    Verhoeven, J.; Stellmach, S.

    2012-12-01

    One of the most striking features of giant planets like Jupiter and Saturn are the zonal wind patterns observed on their surfaces. The mechanism that drives this differential rotation is still not clearly identified and is currently strongly debated in the astro- and geophysics community. Different mechanisms have been proposed over the last decades. Here, a recently discovered mechanism based on background density stratification (Glatzmaier et al., 2009) is investigated. This mechanism has the potential to overcome known difficulties of previous explanations and its efficiency has been demonstrated in 2-d simulations covering equatorial planes. By performing highly resolved numerical simulations in a local Cartesian geometry, we are able to test the efficiency and functionality of this mechanism in turbulent, rotating convection in three spatial dimensions. The choice of a Cartesian model geometry naturally excludes other known mechanisms capable of producing differential rotation, thus allowing us to investigate the role of density stratification in isolation. Typically, the dynamics can be classified into two main regimes: A regime exhibiting strong zonal winds for weak to moderate thermal driving and a regime where zonal winds are largely absent in the case of a strong thermal forcing. Our results indicate that previous 2-d results must be handled with care and can only explain parts of the full 3-d behavior. We show that the density-stratification mechanism tends to operate in a more narrow parameter range in 3-d as compared to 2-d simulations. The dynamics of the regime transition is shown to differ in both cases, which renders scaling laws derived from two-dimensional studies questionable. Based on our results, we provide estimates for the importance of the density-stratification mechanism for giant planets like Jupiter (strong density stratification), for systems like the Earth's core (weak density stratification) and compare its efficiency with other suggested mechanisms for driving differential rotation. Gary A. Glatzmaier, Martha Evonuk and Tamara M. Rogers (2009), Differential rotation in giant planets maintained by density-stratified turbulent convection. Geophysical and Astrophysical Fluid Dynamics, Vol. 103, No. 1, 31-51.

  4. Rotating night shifts too quickly may cause anxiety and decreased attentional performance, and impact prolactin levels during the subsequent day: a case control study.

    PubMed

    Chang, Yu-San; Chen, Hsiang-Lan; Wu, Yu-Hsuan; Hsu, Chung-Yao; Liu, Ching-Kuan; Hsu, Chin

    2014-08-05

    We investigated circadian changes and effects on mood, sleep-related hormones and cognitive performance when nurses worked consecutive night shifts in a rapidly rotating shift system. Daytime cognitive function, sleep propensity and sleep-related hormones (growth hormone, cortisol, prolactin, thyrotropin) were compared after participants worked two and four consecutive night shifts. Twenty-three off-duty nurses, 20 nurses working two consecutive night shifts and 16 nurses working four consecutive night shifts were enrolled. All participants completed the Maintenance of Wakefulness Test, State-Trait Anxiety Inventory, Stanford Sleepiness Scale, visual attention tasks (VAT), Wisconsin Card Sorting Test, and modified Multiple Sleep Latency Test. Hormone levels were also measured four times throughout the day, at 2-h intervals. During the day, the participants in the night shift groups were less able to maintain wakefulness, had poor performance on VAT, and higher thyrotropin levels than did those in the off-duty group. Participants who worked two night shifts were better able to maintain wakefulness, had higher anxiety scale scores, poorer initial performance and lack of learning effect on VAT, and higher prolactin levels compared with those who worked four night shifts. There were no differences in cortisol levels between the two- and four- shift groups. Rotating night shifts too quickly may cause anxiety and decreased attentional performance, and may impact daytime prolactin levels after night shifts. It is possible that the two-shift group had a higher cortisol level than did the four-shift group, which would be consistent with the group's higher state anxiety scores. The negative findings may be due to the small sample size. Further studies on the effects of consecutive night shifts on mood and cortisol levels during the daytime after sleep restriction would be valuable.

  5. Synchrotron radiation Mössbauer spectra of a rotating absorber with implications for testing velocity and acceleration time dilation.

    PubMed

    Friedman, Y; Yudkin, E; Nowik, I; Felner, I; Wille, H-C; Röhlsberger, R; Haber, J; Wortmann, G; Arogeti, S; Friedman, M; Brand, Z; Levi, N; Shafir, I; Efrati, O; Frumson, T; Finkelstein, A; Chumakov, A I; Kantor, I; Rüffer, R

    2015-05-01

    Many Mössbauer spectroscopy (MS) experiments have used a rotating absorber in order to measure the second-order transverse Doppler (TD) shift, and to test the validity of the Einstein time dilation theory. From these experiments, one may also test the clock hypothesis (CH) and the time dilation caused by acceleration. In such experiments the absorption curves must be obtained, since it cannot be assumed that there is no broadening of the curve during the rotation. For technical reasons, it is very complicated to keep the balance of a fast rotating disk if there are moving parts on it. Thus, the Mössbauer source on a transducer should be outside the disk. Friedman and Nowik have already predicted that the X-ray beam finite size dramatically affects the MS absorption line and causes its broadening. We provide here explicit formulas to evaluate this broadening for a synchrotron Mössbauer source (SMS) beam. The broadening is linearly proportional to the rotation frequency and to the SMS beam width at the rotation axis. In addition, it is shown that the TD shift and the MS line broadening are affected by an additional factor assigned as the alignment shift which is proportional to the frequency of rotation and to the distance between the X-ray beam center and the rotation axis. This new shift helps to align the disk's axis of rotation to the X-ray beam's center. To minimize the broadening, one must focus the X-ray on the axis of the rotating disk and/or to add a slit positioned at the center, to block the rays distant from the rotation axis of the disk. Our experiment, using the (57)Fe SMS, currently available at the Nuclear Resonance beamline (ID18) at the ESRF, with a rotating stainless steel foil, confirmed our predictions. With a slit installed at the rotation axis (reducing the effective beam width from 15.6 µm to 5.4 µm), one can measure a statistically meaningful absorption spectrum up to 300 Hz, while, without a slit, such spectra could be obtained up to 100 Hz only. Thus, both the broadening and the alignment shift are very significant and must be taken into consideration in any rotating absorber experiment. Here a method is offered to measure accurately the TD shift and to test the CH.

  6. Geometry of tracer trajectories in rotating turbulent flows

    NASA Astrophysics Data System (ADS)

    Alards, Kim M. J.; Rajaei, Hadi; Del Castello, Lorenzo; Kunnen, Rudie P. J.; Toschi, Federico; Clercx, Herman J. H.

    2017-04-01

    The geometry of passive tracer trajectories is studied in two different types of rotating turbulent flows; rotating Rayleigh-Bénard convection (RBC; experiments and direct numerical simulations) and rotating electromagnetically forced turbulence (EFT; experiments). This geometry is fully described by the curvature and torsion of trajectories, and from these geometrical quantities we can subtract information on the typical flow structures at different rotation rates. Previous studies, focusing on nonrotating homogeneous isotropic turbulence (HIT), show that the probability density functions (PDFs) of curvature and torsion reveal pronounced power laws. However, the set-ups studied here involve inhomogeneous turbulence, and in RBC the flow near the horizontal plates is definitely anisotropic. We investigate how the typical shapes of the curvature and torsion PDFs, including the pronounced scaling laws, are influenced by this level of anisotropy and inhomogeneity and how this effect changes with rotation. A first effect of rotation is observed as a shift of the curvature and torsion PDFs towards higher values in the case of RBC and towards lower values in the case of EFT. This shift is related to the length scale of typical vortical structures that decreases with rotation in RBC, but increases with rotation in EFT, explaining the opposite shifts of the curvature (and torsion) PDFs. A second remarkable observation is that in RBC the HIT scaling laws are always recovered, as long as the boundary layer (BL) is excluded. This suggests that these scaling laws are very robust and hold as long as we measure in the turbulent bulk. In the BL of the RBC cell, however, the scaling deviates from the HIT prediction for lower rotation rates. This scaling behavior is found to be consistent with the coupling between the boundary layer dynamics and the bulk flow, which changes under rotation. In particular, it is found that the active coupling of the Ekman-type boundary layer with the bulk flow suppresses anisotropy in the BL region for increasing rotation rates.

  7. Numerical and experimental investigation of the bending response of thin-walled composite cylinders

    NASA Technical Reports Server (NTRS)

    Fuchs, J. P.; Hyer, M. W.; Starnes, J. H., Jr.

    1993-01-01

    A numerical and experimental investigation of the bending behavior of six eight-ply graphite-epoxy circular cylinders is presented. Bending is induced by applying a known end-rotation to each end of the cylinders, analogous to a beam in bending. The cylinders have a nominal radius of 6 inches, a length-to-radius ratio of 2 and 5, and a radius-to-thickness ratio of approximately 160. A (+/- 45/0/90)S quasi-isotropic layup and two orthotropic layups, (+/- 45/0 sub 2)S and (+/- 45/90 sub 2)S, are studied. A geometrically nonlinear special-purpose analysis, based on Donnell's nonlinear shell equations, is developed to study the prebuckling responses and gain insight into the effects of non-ideal boundary conditions and initial geometric imperfections. A geometrically nonlinear finite element analysis is utilized to compare with the prebuckling solutions of the special-purpose analysis and to study the buckling and post buckling responses of both geometrically perfect and imperfect cylinders. The imperfect cylinder geometries are represented by an analytical approximation of the measured shape imperfections. Extensive experimental data are obtained from quasi-static tests of the cylinders using a test fixture specifically designed for the present investigation. A description of the test fixture is included. The experimental data are compared to predictions for both perfect and imperfect cylinder geometries. Prebuckling results are presented in the form of displacement and strain profiles. Buckling end-rotations, moments, and strains are reported, and predicted mode shapes are presented. Observed and predicted moment vs. end-rotation relations, deflection patterns, and strain profiles are illustrated for the post buckling responses. It is found that a geometrically nonlinear boundary layer behavior characterizes the prebuckling responses. The boundary layer behavior is sensitive to laminate orthotropy, cylinder geometry, initial geometric imperfections, applied end-rotation, and non-ideal boundary conditions. Buckling end-rotations, strains, and moments are influenced by laminate orthotropy and initial geometric imperfections. Measured buckling results correlate well with predictions for the geometrically imperfect specimens. The postbuckling analyses predict equilibrium paths with a number of scallop-shaped branches that correspond to unique deflection patterns. The observed postbuckling deflection patterns and measured strain profiles show striking similarities to the predictions in some cases. Ultimate failure of the cylinders is attributed to an interlaminar shear failure mode along the nodal lines of the postbuckling deflection patterns.

  8. Wandering spleen with gastric volvulus and intestinal non-rotation in an adult male patient

    PubMed Central

    Kohda, Eiichi; Iizuka, Yuo; Nagamoto, Masashi; Ishii, Tomotaka; Saida, Yoshihisa; Shimizu, Norikazu; Gomi, Tatsuya

    2013-01-01

    We report an extremely rare case of wandering spleen (WS) complicated with gastric volvulus and intestinal non-rotation in a male adult. A 22-year-old man who had been previously treated for Wilson disease was admitted with severe abdominal pain. Radiological findings showed WS in the midline of the pelvic area. The stomach was mesenteroaxially twisted and intestinal non-rotation was observed. Radiology results did not show any evidence of splenic or gastrointestinal (GI) infarction. Elective emergency laparoscopy confirmed WS and intestinal non-rotation; however, gastric volvulus was not observed. It was suspected that the stomach had untwisted when gastric and laparoscopic tubes were inserted. Surgery is strongly recommended for WS because of the high risk of serious complications; however, some asymptomatic adult patients are still treated conservatively, such as the patient in this study. The present case is reported with reference to the literature. PMID:24349711

  9. Wandering spleen with gastric volvulus and intestinal non-rotation in an adult male patient.

    PubMed

    Ooka, Minako; Kohda, Eiichi; Iizuka, Yuo; Nagamoto, Masashi; Ishii, Tomotaka; Saida, Yoshihisa; Shimizu, Norikazu; Gomi, Tatsuya

    2013-01-01

    We report an extremely rare case of wandering spleen (WS) complicated with gastric volvulus and intestinal non-rotation in a male adult. A 22-year-old man who had been previously treated for Wilson disease was admitted with severe abdominal pain. Radiological findings showed WS in the midline of the pelvic area. The stomach was mesenteroaxially twisted and intestinal non-rotation was observed. Radiology results did not show any evidence of splenic or gastrointestinal (GI) infarction. Elective emergency laparoscopy confirmed WS and intestinal non-rotation; however, gastric volvulus was not observed. It was suspected that the stomach had untwisted when gastric and laparoscopic tubes were inserted. Surgery is strongly recommended for WS because of the high risk of serious complications; however, some asymptomatic adult patients are still treated conservatively, such as the patient in this study. The present case is reported with reference to the literature.

  10. Effect of Spacecraft Rotation on Fluid Convection Under Microgravity

    NASA Technical Reports Server (NTRS)

    Yuferev, Valentin S.; Kolesnikova, Elvira N.; Polovko, Yuri A.; Zhmakin, Alexander I.

    1996-01-01

    The influence of the rotational effects on two-dimensional fluid convection in a rectangular enclosure with rigid walls during the orbital flight is considered. It is shown that the Coriolis force influence both on steady and oscillatory convection becomes significant at Ekman numbers which are quite attainable in the space orbital conditions. In the case of harmonic oscillations of the gravity force appearance of the resonance phenomena is demonstrated. Dependence of the height and shape of the resonance peak on aspect ratio of a rectangular domain and orientation of vectors of the gravity force and the angular rotation velocity is studied. Special attention is given to non-linear effects caused by convective terms of Navier-Stokes equations. The convection produced by variations of the angular rotation velocity of a spacecraft is also discussed. It is shown that in some cases the latter convection can be comparable with another kinds of convection.

  11. Hydrostatic Equilibria of Rotating Stars with Realistic Equation of State

    NASA Astrophysics Data System (ADS)

    Yasutake, Nobutoshi; Fujisawa, Kotaro; Okawa, Hirotada; Yamada, Shoichi

    Stars rotate generally, but it is a non-trivial issue to obtain hydrostatic equilibria for rapidly rotating stars theoretically, especially for baroclinic cases, in which the pressure depends not only on the density, but also on the temperature and compositions. It is clear that the stellar structures with realistic equation of state are the baroclinic cases, but there are not so many studies for such equilibria. In this study, we propose two methods to obtain hydrostatic equilibria considering rotation and baroclinicity, namely the weak-solution method and the strong-solution method. The former method is based on the variational principle, which is also applied to the calculation of the inhomogeneous phases, known as the pasta structures, in crust of neutron stars. We found this method might break the balance equation locally, then introduce the strong-solution method. Note that our method is formulated in the mass coordinate, and it is hence appropriated for the stellar evolution calculations.

  12. Shadow casted by a Konoplya-Zhidenko rotating non-Kerr black hole

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Mingzhi; Chen, Songbai; Jing, Jiliang, E-mail: wmz9085@126.com, E-mail: csb3752@hunnu.edu.cn, E-mail: jljing@hunnu.edu.cn

    We have investigated the shadow of a Konoplya-Zhidenko rotating non-Kerr black hole with an extra deformation parameter. The spacetime structure arising from the deformed parameter affects sharply the black hole shadow. With the increase of the deformation parameter, the size of the shadow of black hole increase and its shape becomes more rounded for arbitrary rotation parameter. The D-shape shadow of black hole emerges only in the case a <2√3/3\\, M with the proper deformation parameter. Especially, the black hole shadow possesses a cusp shape with small eye lashes in the cases with a >M, and the shadow becomes lessmore » cuspidal with the increase of the deformation parameter. Our result show that the presence of the deformation parameter yields a series of significant patterns for the shadow casted by a Konoplya-Zhidenko rotating non-Kerr black hole.« less

  13. Nonlinear dynamics and anisotropic structure of rotating sheared turbulence.

    PubMed

    Salhi, A; Jacobitz, F G; Schneider, K; Cambon, C

    2014-01-01

    Homogeneous turbulence in rotating shear flows is studied by means of pseudospectral direct numerical simulation and analytical spectral linear theory (SLT). The ratio of the Coriolis parameter to shear rate is varied over a wide range by changing the rotation strength, while a constant moderate shear rate is used to enable significant contributions to the nonlinear interscale energy transfer and to the nonlinear intercomponental redistribution terms. In the destabilized and neutral cases, in the sense of kinetic energy evolution, nonlinearity cannot saturate the growth of the largest scales. It permits the smallest scale to stabilize by a scale-by-scale quasibalance between the nonlinear energy transfer and the dissipation spectrum. In the stabilized cases, the role of rotation is mainly nonlinear, and interacting inertial waves can affect almost all scales as in purely rotating flows. In order to isolate the nonlinear effect of rotation, the two-dimensional manifold with vanishing spanwise wave number is revisited and both two-component spectra and single-point two-dimensional energy components exhibit an important effect of rotation, whereas the SLT as well as the purely two-dimensional nonlinear analysis are unaffected by rotation as stated by the Proudman theorem. The other two-dimensional manifold with vanishing streamwise wave number is analyzed with similar tools because it is essential for any shear flow. Finally, the spectral approach is used to disentangle, in an analytical way, the linear and nonlinear terms in the dynamical equations.

  14. Surgical Pathology Resident Rotation Restructuring at a Tertiary Care Academic Center.

    PubMed

    Mehr, Chelsea R; Obstfeld, Amrom E; Barrett, Amanda C; Montone, Kathleen T; Schwartz, Lauren E

    2017-01-01

    Changes in the field of pathology and resident education necessitate ongoing evaluation of residency training. Evolutionary change is particularly important for surgical pathology rotations, which form the core of anatomic pathology training programs. In the past, we organized this rotation based on subjective insight. When faced with the recent need to restructure the rotation, we strove for a more evidence-based process. Our approach involved 2 primary sources of data. We quantified the number of cases and blocks submitted per case type to estimate workload and surveyed residents about the time required to gross specimens in all organ systems. A multidisciplinary committee including faculty, residents, and staff evaluated the results and used the data to model how various changes to the rotation would affect resident workload, turnaround time, and other variables. Finally, we identified rotation structures that equally distributed work and created a point-based system that capped grossing time for residents of different experience. Following implementation, we retrospectively compared turnaround time and duty hour violations before and after these changes and surveyed residents about their experiences with both systems. We evaluated the accuracy of the point-based system by examining grossing times and comparing them to the assigned point values. We found overall improvement in the rotation following the implementation. As there is essentially no literature on the subject of surgical pathology rotation organization, we hope that our experience will provide a road map to improve pathology resident education at other institutions.

  15. STABILITY OF ROTATING MAGNETIZED JETS IN THE SOLAR ATMOSPHERE. I. KELVIN–HELMHOLTZ INSTABILITY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zaqarashvili, Teimuraz V.; Zhelyazkov, Ivan; Ofman, Leon, E-mail: teimuraz.zaqarashvili@uni-graz.at

    2015-11-10

    Observations show various jets in the solar atmosphere with significant rotational motions, which may undergo instabilities leading to heat ambient plasma. We study the Kelvin–Helmholtz instability (KHI) of twisted and rotating jets caused by the velocity jumps near the jet surface. We derive a dispersion equation with appropriate boundary conditions for total pressure (including centrifugal force of tube rotation), which governs the dynamics of incompressible jets. Then, we obtain analytical instability criteria of KHI in various cases, which were verified by numerical solutions to the dispersion equation. We find that twisted and rotating jets are unstable to KHI when themore » kinetic energy of rotation is more than the magnetic energy of the twist. Our analysis shows that the azimuthal magnetic field of 1–5 G can stabilize observed rotations in spicule/macrospicules and X-ray/extreme-ultraviolet (EUV) jets. On the other hand, nontwisted jets are always unstable to KHI. In this case, the instability growth time is several seconds for spicule/macrospicules and a few minutes (or less) for EUV/X-ray jets. We also find that standing kink and torsional Alfvén waves are always unstable near the antinodes, owing to the jump of azimuthal velocity at the surface, while the propagating waves are generally stable. Kelvin–Helmholtz (KH) vortices may lead to enhanced turbulence development and heating of surrounding plasma; therefore, rotating jets may provide energy for chromospheric and coronal heating.« less

  16. Rotating gravity currents. Part 1. Energy loss theory

    NASA Astrophysics Data System (ADS)

    Martin, J. R.; Lane-Serff, G. F.

    2005-01-01

    A comprehensive energy loss theory for gravity currents in rotating rectangular channels is presented. The model is an extension of the non-rotating energy loss theory of Benjamin (J. Fluid Mech. vol. 31, 1968, p. 209) and the steady-state dissipationless theory of rotating gravity currents of Hacker (PhD thesis, 1996). The theory assumes the fluid is inviscid, there is no shear within the current, and the Boussinesq approximation is made. Dissipation is introduced using a simple method. A head loss term is introduced into the Bernoulli equation and it is assumed that the energy loss is uniform across the stream. Conservation of momentum, volume flux and potential vorticity between upstream and downstream locations is then considered. By allowing for energy dissipation, results are obtained for channels of arbitrary depth and width (relative to the current). The results match those from earlier workers in the two limits of (i) zero rotation (but including dissipation) and (ii) zero dissipation (but including rotation). Three types of flow are identified as the effect of rotation increases, characterized in terms of the location of the outcropping interface between the gravity current and the ambient fluid on the channel boundaries. The parameters for transitions between these cases are quantified, as is the detailed behaviour of the flow in all cases. In particular, the speed of the current can be predicted for any given channel depth and width. As the channel depth increases, the predicted Froude number tends to surd 2, as for non-rotating flows.

  17. Experimental impact testing and analysis of composite fan cases

    NASA Astrophysics Data System (ADS)

    Vander Klok, Andrew Joe

    For aircraft engine certification, one of the requirements is to demonstrate the ability of the engine to withstand a fan blade-out (FBO) event. A FBO event may be caused by fatigue failure of the fan blade itself or by impact damage of foreign objects such as bird strike. An un-contained blade can damage flight critical engine components or even the fuselage. The design of a containment structure is related to numerous parameters such as the blade tip speed; blade material, size and shape; hub/tip diameter; fan case material, configuration, rigidity, etc. To investigate all parameters by spin experiments with a full size rotor assembly can be prohibitively expensive. Gas gun experiments can generate useful data for the design of engine containment cases at much lower costs. To replicate the damage modes similar to that on a fan case in FBO testing, the gas gun experiment has to be carefully designed. To investigate the experimental procedure and data acquisition techniques for FBO test, a low cost, small spin rig was first constructed. FBO tests were carried out with the small rig. The observed blade-to-fan case interactions were similar to those reported using larger spin rigs. The small rig has the potential in a variety of applications from investigating FBO events, verifying concept designs of rotors, to developing spin testing techniques. This rig was used in the developments of the notched blade releasing mechanism, a wire trigger method for synchronized data acquisition, high speed video imaging and etc. A relationship between the notch depth and the release speed was developed and verified. Next, an original custom designed spin testing facility was constructed. Driven by a 40HP, 40,000rpm air turbine, the spin rig is housed in a vacuum chamber of phi72inx40in (1829mmx1016mm). The heavily armored chamber is furnished with 9 viewports. This facility enables unprecedented investigations of FBO events. In parallel, a 15.4ft (4.7m) long phi4.1inch (105mm) diameter single stage gas gun was developed. A thermodynamic based relationship between the required gas pressure and targeted velocity was proposed. The predicted velocity was within +/-7%. Quantitative measurements of force and displacement were attempted. The transmitted impact force was measured with load cells. The out-of-plane deformation was measured with a projection grating profilometry method. The composite panels and fan cases used in this work were made of S2-glass plain weave fabrics with API SC-15 toughened epoxy resin using the vacuum assisted resin transfer molding (VARTM) method. Using the gas gun, the impact behavior of the composite was investigated at velocities ranging from 984ft/s to 1502ft/s (300m/s to 458m/s) following a draft ASTM testing standard. To compare the ballistic protection capability of different materials, a new parameter EBL, the projectile kinetic energy at the target ballistic limit normalized by the contact area of the projectile, was proposed. S2-glass/epoxy composite is ranked very high in EBL per areal weight. Finally, a testing method for replicating spin pit testing with a gas gun test was developed. Major differences between the two tests are the initial conditions of the blade upon contact with the target. In spin testing, the released blade has two velocity components, rotational and translational whereas in gas gun testing, the projectile has only the translational velocity. To account for the influence of the rotational velocity, three projectile designs were experimentally investigated. The results show that to generate similar damage modes in gas gun testing, it is critical to ensure the deformation of the projectile before testing is similar to that of a released blade. With the pre-bent blade, the gas gun experiment was able to replicate the damage modes of the fan case in FBO test on flat composite panels.

  18. The value of physical examination in the diagnosis of hip osteoarthritis.

    PubMed

    Chong, Timothy; Don, Darren W; Kao, Ming-Chih; Wong, Dexter; Mitra, Raj

    2013-01-01

    To compare the sensitivity of physical examination (internal rotation of the hip) with radiographs (using the Kellgren-Lawrence grading scale) in the diagnosis of clinically significant hip osteoarthritis. Case Series, Retrospective chart review of hip pain patients that underwent fluoroscopically guided hip steroid and anesthetic injections. 10 patients with hip pain patients seen at an academic outpatient center over a 2 year period were analyzed. Fluoroscopically guided hip steroid and anesthetic injection. Pain relief and change in VAS pain score after intra-articular hip steroid and lidocaine injection was the main outcome measure. Based on Fisher's exact test, there was no association between severity of radiographic hip arthritis and pain relief with intra-articular anesthetic/steroid injection (p=0.45). Physical examination (provocative hip internal rotation) however was associated with a significant decrease in VAS pain score after intra-articular lidocaine and corticosteroid hip injection (p=0.022). Simple hip radiographs alone are not sufficient to diagnose clinically significant hip osteoarthritis. Physical examination (hip internal rotation) was found to be more accurate than simple radiographs in the diagnosis of clinically significant hip osteoarthritis. Radiographs seem to best utilized when they are an extension of the physical examination and patient history.

  19. A simple depth-averaged model for dry granular flow

    NASA Astrophysics Data System (ADS)

    Hung, Chi-Yao; Stark, Colin P.; Capart, Herve

    Granular flow over an erodible bed is an important phenomenon in both industrial and geophysical settings. Here we develop a depth-averaged theory for dry erosive flows using balance equations for mass, momentum and (crucially) kinetic energy. We assume a linearized GDR-Midi rheology for granular deformation and Coulomb friction along the sidewalls. The theory predicts the kinematic behavior of channelized flows under a variety of conditions, which we test in two sets of experiments: (1) a linear chute, where abrupt changes in tilt drive unsteady uniform flows; (2) a rotating drum, to explore steady non-uniform flow. The theoretical predictions match the experimental results well in all cases, without the need to tune parameters or invoke an ad hoc equation for entrainment at the base of the flow. Here we focus on the drum problem. A dimensionless rotation rate (related to Froude number) characterizes flow geometry and accounts not just for spin rate, drum radius and gravity, but also for grain size, wall friction and channel width. By incorporating Coriolis force the theory can treat behavior under centrifuge-induced enhanced gravity. We identify asymptotic flow regimes at low and high dimensionless rotation rates that exhibit distinct power-law scaling behaviors.

  20. Rotational stability test for the diagnosis of radial collateral ligament rupture in the fingers: Anatomical study.

    PubMed

    Lazarus, P; Hidalgo Diaz, J J; Prunières, G; Pire, E; Taleb, C; Honecker, S; Bellemère, P; Fontaine, C; Liverneaux, P A

    2017-04-01

    Diagnosing rupture of the radial collateral ligament (RCL) of the finger metacarpophalangeal (MCP) joints is difficult. The aim of this cadaver study was to validate a rotational test for the MCP after RCL transection. With the MCP and proximal interphalangeal joints in flexion, rotation along the axis of the proximal phalanx was applied through an extended distal interphalangeal joint to 36 cadaver fingers. Each finger's pulp described an arc of pronation and supination that was noted on the palm. The test was repeated three times: before transection, after transection of the proper collateral ligament (CL) and after transection of both the proper and accessory CLs. Rotational arcs were measured in pronation and supination. Mean length of the pronation arc after transection of the main RCL was 17.53mm, while it was only 12.41mm before transection for the supination arc. Mean length of the pronation arc after transection of both CLs was 22.83mm compared to only 11.93mm before transection. Our results show a significant difference in pronation stability of the MCP joint after transection of the RCL proper. We can conclude that this rotational stability test is a valid test for diagnosing RCL rupture in MCP joints. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  1. Multi-Layer Artificial Neural Networks Based MPPT-Pitch Angle Control of a Tidal Stream Generator

    PubMed Central

    Bouallègue, Soufiene; Garrido, Aitor J.; Haggège, Joseph

    2018-01-01

    Artificial intelligence technologies are widely investigated as a promising technique for tackling complex and ill-defined problems. In this context, artificial neural networks methodology has been considered as an effective tool to handle renewable energy systems. Thereby, the use of Tidal Stream Generator (TSG) systems aim to provide clean and reliable electrical power. However, the power captured from tidal currents is highly disturbed due to the swell effect and the periodicity of the tidal current phenomenon. In order to improve the quality of the generated power, this paper focuses on the power smoothing control. For this purpose, a novel Artificial Neural Network (ANN) is investigated and implemented to provide the proper rotational speed reference and the blade pitch angle. The ANN supervisor adequately switches the system in variable speed and power limitation modes. In order to recover the maximum power from the tides, a rotational speed control is applied to the rotor side converter following the Maximum Power Point Tracking (MPPT) generated from the ANN block. In case of strong tidal currents, a pitch angle control is set based on the ANN approach to keep the system operating within safe limits. Two study cases were performed to test the performance of the output power. Simulation results demonstrate that the implemented control strategies achieve a smoothed generated power in the case of swell disturbances. PMID:29695127

  2. Multi-Layer Artificial Neural Networks Based MPPT-Pitch Angle Control of a Tidal Stream Generator.

    PubMed

    Ghefiri, Khaoula; Bouallègue, Soufiene; Garrido, Izaskun; Garrido, Aitor J; Haggège, Joseph

    2018-04-24

    Artificial intelligence technologies are widely investigated as a promising technique for tackling complex and ill-defined problems. In this context, artificial neural networks methodology has been considered as an effective tool to handle renewable energy systems. Thereby, the use of Tidal Stream Generator (TSG) systems aim to provide clean and reliable electrical power. However, the power captured from tidal currents is highly disturbed due to the swell effect and the periodicity of the tidal current phenomenon. In order to improve the quality of the generated power, this paper focuses on the power smoothing control. For this purpose, a novel Artificial Neural Network (ANN) is investigated and implemented to provide the proper rotational speed reference and the blade pitch angle. The ANN supervisor adequately switches the system in variable speed and power limitation modes. In order to recover the maximum power from the tides, a rotational speed control is applied to the rotor side converter following the Maximum Power Point Tracking (MPPT) generated from the ANN block. In case of strong tidal currents, a pitch angle control is set based on the ANN approach to keep the system operating within safe limits. Two study cases were performed to test the performance of the output power. Simulation results demonstrate that the implemented control strategies achieve a smoothed generated power in the case of swell disturbances.

  3. Sex Differences in Mental Rotation Tasks: Not Just in the Mental Rotation Process!

    ERIC Educational Resources Information Center

    Boone, Alexander P.; Hegarty, Mary

    2017-01-01

    The paper-and-pencil Mental Rotation Test (Vandenberg & Kuse, 1978) consistently produces large sex differences favoring men (Voyer, Voyer, & Bryden, 1995). In this task, participants select 2 of 4 answer choices that are rotations of a probe stimulus. Incorrect choices (i.e., foils) are either mirror reflections of the probe or…

  4. Asymmetrical perception of body rotation after unilateral injury to human vestibular cortex.

    PubMed

    Philbeck, John W; Behrmann, Marlene; Biega, Tim; Levy, Lucien

    2006-01-01

    Vestibular information plays a key role in many perceptual and cognitive functions, but surprisingly little is known about how vestibular signals are processed at the cortical level in humans. To address this issue, we tested the ability of two patients, with damage to key components of the vestibular network in either the left or right hemisphere, to perceive passive whole-body rotations (25-125 degrees) about the yaw axis. In both patients, the posterior insula, hippocampus, putamen, and thalamus were extensively damaged. The patients' responses were compared with those of nine age- and sex-matched neurologically intact participants. The body rotations were conducted without vision and the peak angular velocities ranged from 40 degrees to 90 degrees per second. Perceived rotation was assessed by open-loop manual pointing. The right hemisphere patient exhibited poor sensitivity for body rotations toward the contralesional (left) hemispace and generally underestimated the rotations. By contrast, his judgments of rotations toward the ipsilesional (right) hemispace greatly overestimated the physical rotation by 50-70 degrees for all tested magnitudes. The left hemisphere patient's responses were more appropriately scaled for both rotation directions, falling in the low-normal range. These findings suggest that there is some degree of hemispheric specialization in the cortical processing of dynamic head rotations in the yaw plane. In this view, right hemisphere structures play a dominant role, processing rotations in both directions, while left hemisphere structures process rotations only toward the contralesional hemispace.

  5. Counter-Rotatable Fan Gas Turbine Engine with Axial Flow Positive Displacement Worm Gas Generator

    NASA Technical Reports Server (NTRS)

    Giffin, Rollin George (Inventor); Murrow, Kurt David (Inventor); Fakunle, Oladapo (Inventor)

    2014-01-01

    A counter-rotatable fan turbine engine includes a counter-rotatable fan section, a worm gas generator, and a low pressure turbine to power the counter-rotatable fan section. The low pressure turbine maybe counter-rotatable or have a single direction of rotation in which case it powers the counter-rotatable fan section through a gearbox. The gas generator has inner and outer bodies having offset inner and outer axes extending through first, second, and third sections of a core assembly. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes and extending radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. A combustor section extends through at least a portion of the second section.

  6. Three-dimensional simulations of rapidly rotating core-collapse supernovae: finding a neutrino-powered explosion aided by non-axisymmetric flows

    NASA Astrophysics Data System (ADS)

    Takiwaki, Tomoya; Kotake, Kei; Suwa, Yudai

    2016-09-01

    We report results from a series of three-dimensional (3D) rotational core-collapse simulations for 11.2 and 27 M⊙ stars employing neutrino transport scheme by the isotropic diffusion source approximation. By changing the initial strength of rotation systematically, we find a rotation-assisted explosion for the 27 M⊙ progenitor , which fails in the absence of rotation. The unique feature was not captured in previous two-dimensional (2D) self-consistent rotating models because the growing non-axisymmetric instabilities play a key role. In the rapidly rotating case, strong spiral flows generated by the so-called low T/|W| instability enhance the energy transport from the proto-neutron star (PNS) to the gain region, which makes the shock expansion more energetic. The explosion occurs more strongly in the direction perpendicular to the rotational axis, which is different from previous 2D predictions.

  7. Socio-ecological implications of modifying rotation lengths in forestry.

    PubMed

    Roberge, Jean-Michel; Laudon, Hjalmar; Björkman, Christer; Ranius, Thomas; Sandström, Camilla; Felton, Adam; Sténs, Anna; Nordin, Annika; Granström, Anders; Widemo, Fredrik; Bergh, Johan; Sonesson, Johan; Stenlid, Jan; Lundmark, Tomas

    2016-02-01

    The rotation length is a key component of even-aged forest management systems. Using Fennoscandian forestry as a case, we review the socio-ecological implications of modifying rotation lengths relative to current practice by evaluating effects on a range of ecosystem services and on biodiversity conservation. The effects of shortening rotations on provisioning services are expected to be mostly negative to neutral (e.g. production of wood, bilberries, reindeer forage), while those of extending rotations would be more varied. Shortening rotations may help limit damage by some of today's major damaging agents (e.g. root rot, cambium-feeding insects), but may also increase other damage types (e.g. regeneration pests) and impede climate mitigation. Supporting (water, soil nutrients) and cultural (aesthetics, cultural heritage) ecosystem services would generally be affected negatively by shortened rotations and positively by extended rotations, as would most biodiversity indicators. Several effect modifiers, such as changes to thinning regimes, could alter these patterns.

  8. Three-dimensional solutions of the magnetohydrostatic equations for rigidly rotating magnetospheres in cylindrical coordinates

    NASA Astrophysics Data System (ADS)

    Wilson, F.; Neukirch, T.

    2018-01-01

    We present new analytical three-dimensional solutions of the magnetohydrostatic equations, which are applicable to the co-rotating frame of reference outside a rigidly rotating cylindrical body, and have potential applications to planetary magnetospheres and stellar coronae. We consider the case with centrifugal force only, and use a transformation method in which the governing equation for the "pseudo-potential" (from which the magnetic field can be calculated) becomes the Laplace partial differential equation. The new solutions extend the set of previously found solutions to those of a "fractional multipole" nature, and offer wider possibilities for modelling than before. We consider some special cases, and present example solutions.

  9. Full-field Deformation Measurement Techniques for a Rotating Composite Shaft

    NASA Technical Reports Server (NTRS)

    Kohlman, Lee W.; Ruggeri, Charles R.; Martin, Richard E.; Roberts, Gary D.; Handschuh, Robert F.; Roth, Don J.

    2012-01-01

    Test methods were developed to view global and local deformation in a composite tube during a test in which the tube is rotating at speeds and torques relevant to rotorcraft shafts. Digital image correlation (DIC) was used to provide quantitative displacement measurements during the tests. High speed cameras were used for the DIC measurements in order to capture images at sufficient frame rates and with sufficient resolution while the tube was rotating at speeds up to 5,000 rpm. Surface displacement data was resolved into cylindrical coordinates in order to measure rigid body rotation and global deformation of the tube. Tests were performed on both undamaged and impact damaged tubes in order to evaluate the capability to detect local deformation near an impact damaged site. Measurement of radial displacement clearly indicated a local buckling deformation near the impacted site in both dynamic and static tests. X-ray computed tomography (CT) was used to investigate variations in fiber architecture within the composite tube and to detect impact damage. No growth in the impact damage area was observed by DIC during dynamic testing or by x-ray CT in post test inspection of the composite tube.

  10. Hawking radiation in a rotating Kaluza-Klein black hole with squashed horizons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen Songbai; Wang Bin; Su Rukeng

    2008-01-15

    We explore the signature of the extra dimension in the Hawking radiation in a rotating Kaluza-Klein black hole with squashed horizons. Comparing with the spherical case, we find that the rotating parameter brings richer physics. We obtain the appropriate size of the extra dimension which can enhance the Hawking radiation and may open a window to detect the extra dimensions.

  11. Instability in Rotating Machinery

    NASA Technical Reports Server (NTRS)

    1985-01-01

    The proceedings contain 45 papers on a wide range of subjects including flow generated instabilities in fluid flow machines, cracked shaft detection, case histories of instability phenomena in compressors, turbines, and pumps, vibration control in turbomachinery (including antiswirl techniques), and the simulation and estimation of destabilizing forces in rotating machines. The symposium was held to serve as an update on the understanding and control of rotating machinery instability problems.

  12. Reliabilities of mental rotation tasks: limits to the assessment of individual differences.

    PubMed

    Hirschfeld, Gerrit; Thielsch, Meinald T; Zernikow, Boris

    2013-01-01

    Mental rotation tasks with objects and body parts as targets are widely used in cognitive neuropsychology. Even though these tasks are well established to study between-groups differences, the reliability on an individual level is largely unknown. We present a systematic study on the internal consistency and test-retest reliability of individual differences in mental rotation tasks comparing different target types and orders of presentations. In total n = 99 participants (n = 63 for the retest) completed the mental rotation tasks with hands, feet, faces, and cars as targets. Different target types were presented in either randomly mixed blocks or blocks of homogeneous targets. Across all target types, the consistency (split-half reliability) and stability (test-retest reliabilities) were good or acceptable both for intercepts and slopes. At the level of individual targets, only intercepts showed acceptable reliabilities. Blocked presentations resulted in significantly faster and numerically more consistent and stable responses. Mental rotation tasks-especially in blocked variants-can be used to reliably assess individual differences in global processing speed. However, the assessment of the theoretically important slope parameter for individual targets requires further adaptations to mental rotation tests.

  13. Assessment and treatment strategies for rotator cuff tears

    PubMed Central

    Al-Hakim, Wisam; Noorani, Ali

    2014-01-01

    Tears of the rotator cuff are common and becoming an increasingly frequent problem. There is a vast amount of literature on the merits and limitations of the various methods of clinical and radiological assessment of rotator cuff tears. This is also the case with regard to treatment strategies. Certain popular beliefs and principles practiced widely and the basis upon which they are derived may be prone to inaccuracy. We provide an overview of the historical management of rotator cuff tears, as well as an explanation for how and why rotator cuff tears should be managed, and propose a structured methodology for their assessment and treatment. PMID:27582960

  14. The pulsation-rotation interaction: Greatest hits and the B-side

    NASA Astrophysics Data System (ADS)

    Townsend, Rich

    2014-02-01

    It has long been known that rotation can have an appreciable impact on stellar pulsation - by modifying the usual p and g modes found in the non-rotating case, and by introducing new classes of modes. However, it's only relatively recently that advances in numerical simulations and complementary theoretical treatments have enabled us to model these phenomena in any great detail. In this talk I'll review highlights in this area (the `Greatest Hits'), before considering the flip side (or the `B-side', for those of us old enough to remember vinyl records) of the pulsation-rotation interaction: how pulsation can itself influence internal rotation profiles.

  15. Behaviour of Rotating Bose Einstein Condensates Under Shrinking

    NASA Astrophysics Data System (ADS)

    Zhai, Hui; Zhou, Qi

    2005-01-01

    When the repulsive interaction strength between atoms decreases, the size of a rotating Bose-Einstein condensate will consequently shrink. We find that the rotational frequency will increase during the shrinking of condensate, which is a quantum mechanical analogy to ballet dancing. Compared to a non-rotating condensate, the size of a rotating BEC will eventually be saturated at a finite value when the interaction strength is gradually reduced. We also calculate the vortex dynamics induced by the atomic current, and discuss the difference of vortex dynamics in this case and that observed in a recent experiment carried out by the JILA group [Phys. Rev. Lett. 90 (2003) 170405].

  16. The fiber optic gyroscope - a portable rotational ground motion sensor

    NASA Astrophysics Data System (ADS)

    Wassermann, J. M.; Bernauer, F.; Guattari, F.; Igel, H.

    2016-12-01

    It was already shown that a portable broadband rotational ground motion sensor will have large impact on several fields of seismological research such as volcanology, marine geophysics, seismic tomography and planetary seismology. Here, we present results of tests and experiments with one of the first broadband rotational motion sensors available. BlueSeis-3A, is a fiber optic gyroscope (FOG) especially designed for the needs of seismology, developed by iXBlue, France, in close collaboration with researchers financed by the European Research council project ROMY (Rotational motions - a new observable for seismology). We first present the instrument characteristics which were estimated by different standard laboratory tests, e.g. self noise using operational range diagrams or Allan deviation. Next we present the results of a field experiment which was designed to demonstrate the value of a 6C measurement (3 components of translation and 3 components of rotation). This field test took place at Mt. Stromboli volcano, Italy, and is accompanied by seismic array installation to proof the FOG output against more commonly known array derived rotation. As already shown with synthetic data an additional direct measurement of three components of rotation can reduce the ambiguity in source mechanism estimation and can be taken to correct for dynamic tilt of the translational sensors (i.e. seismometers). We can therefore demonstrate that the deployment of a weak motion broadband rotational motion sensor is in fact producing superior results by a reduction of the number of deployed instruments.

  17. Testing of the line element of special relativity with rotating systems

    NASA Technical Reports Server (NTRS)

    Vargas, Jose G.; Torr, Douglas G.

    1989-01-01

    Experiments with rotating systems are examined from the point of view of a test theory of the Lorentz transformations (LTs), permitting, in principle, the verification of the simultaneity relation. The significance of the experiments involved in the testing of the LTs can be determined using Robertson's test theory (RTT). A revised RTT is discussed, and attention is given to the Ehrenfest paradox in connection with the testing of the LTs.

  18. Modeling the Conducting Stably-Stratified Layer of the Earth's Core

    NASA Astrophysics Data System (ADS)

    Petitdemange, L.; Philidet, J.; Gissinger, C.

    2017-12-01

    Observations of the Earth magnetic field as well as recent theoretical works tend to show that the Earth's outer liquid core is mostly comprised of a convective zone in which the Earth's magnetic field is generated - likely by dynamo action -, but also features a thin, stably stratified layer at the top of the core.We carry out direct numerical simulations by modeling this thin layer as an axisymmetric spherical Couette flow for a stably stratified fluid embedded in a dipolar magnetic field. The dynamo region is modeled by a conducting inner core rotating slightly faster than the insulating mantle due to magnetic torques acting on it, such that a weak differential rotation (low Rossby limit) can develop in the stably stratified layer.In the case of a non-stratified fluid, the combined action of the differential rotation and the magnetic field leads to the well known regime of `super-rotation', in which the fluid rotates faster than the inner core. Whereas in the classical case, this super-rotation is known to vanish in the magnetostrophic limit, we show here that the fluid stratification significantly extends the magnitude of the super-rotation, keeping this phenomenon relevant for the Earth core. Finally, we study how the shear layers generated by this new state might give birth to magnetohydrodynamic instabilities or waves impacting the secular variations or jerks of the Earth's magnetic field.

  19. Semidiurnal thermal tides in asynchronously rotating hot Jupiters

    NASA Astrophysics Data System (ADS)

    Auclair-Desrotour, P.; Leconte, J.

    2018-05-01

    Context. Thermal tides can torque the atmosphere of hot Jupiters into asynchronous rotation, while these planets are usually assumed to be locked into spin-orbit synchronization with their host star. Aims: In this work, our goal is to characterize the tidal response of a rotating hot Jupiter to the tidal semidiurnal thermal forcing of its host star by identifying the structure of tidal waves responsible for variation of mass distribution, their dependence on the tidal frequency, and their ability to generate strong zonal flows. Methods: We develop an ab initio global modelling that generalizes the early approach of Arras & Socrates (2010, ApJ, 714, 1) to rotating and non-adiabatic planets. We analytically derive the torque exerted on the body and the associated timescales of evolution, as well as the equilibrium tidal response of the atmosphere in the zero-frequency limit. Finally, we numerically integrate the equations of thermal tides for three cases, including dissipation and rotation step by step. Results: The resonances associated with tidally generated gravito-inertial waves significantly amplify the resulting tidal torque in the range 1-30 days. This torque can globally drive the atmosphere into asynchronous rotation, as its sign depends on the tidal frequency. The resonant behaviour of the tidal response is enhanced by rotation, which couples the forcing to several Hough modes in the general case, while the radiative cooling tends to regularize it and diminish its amplitude.

  20. Pressure ulcers and lateral rotation beds: a case study.

    PubMed

    Russell, Teresa; Logsdon, Angela

    2003-05-01

    During a 6-month period, the WOC nurses at a 500-bed medical treatment facility noticed the development of nosocomial pressure ulcers on the sacrum, occiput, and heel areas of patients who were placed on lateral rotation specialty beds because they had pulmonary disorders. Measures were taken to address the problem by repositioning the patients and through a staff education program. Repositioning included repositioning the patient's head every 2 hours, thorough skin assessments every 2 hours, and ensuring that the patient's heels were subject to zero pressure. Staff education centered on the importance of using a risk assessment tool (the Braden scale) and understanding the clinical uses for lateral rotation beds. During the subsequent 6 months, the incidence of hospital-acquired pressure ulcers decreased by 52%. Efforts to further decrease the number of pressure ulcers related to the use of lateral rotation beds continue. Issues such as length of stay on the bed and the appropriateness of manufacturer's guidelines still need to be addressed at this facility. This case study highlights the potential issues associated with lateral rotation beds and identifies the need for further research.

  1. DNA Packaging in Bacteriophage: Is Twist Important?

    PubMed Central

    Spakowitz, Andrew James; Wang, Zhen-Gang

    2005-01-01

    We study the packaging of DNA into a bacteriophage capsid using computer simulation, specifically focusing on the potential impact of twist on the final packaged conformation. We perform two dynamic simulations of packaging a polymer chain into a spherical confinement: one where the chain end is rotated as it is fed, and one where the chain is fed without end rotation. The final packaged conformation exhibits distinct differences in these two cases: the packaged conformation from feeding with rotation exhibits a spool-like character that is consistent with experimental and previous theoretical work, whereas feeding without rotation results in a folded conformation inconsistent with a spool conformation. The chain segment density shows a layered structure, which is more pronounced for packaging with rotation. However, in both cases, the conformation is marked by frequent jumps of the polymer chain from layer to layer, potentially influencing the ability to disentangle during subsequent ejection. Ejection simulations with and without Brownian forces show that Brownian forces are necessary to achieve complete ejection of the polymer chain in the absence of external forces. PMID:15805174

  2. DNA packaging in bacteriophage: is twist important?

    PubMed

    Spakowitz, Andrew James; Wang, Zhen-Gang

    2005-06-01

    We study the packaging of DNA into a bacteriophage capsid using computer simulation, specifically focusing on the potential impact of twist on the final packaged conformation. We perform two dynamic simulations of packaging a polymer chain into a spherical confinement: one where the chain end is rotated as it is fed, and one where the chain is fed without end rotation. The final packaged conformation exhibits distinct differences in these two cases: the packaged conformation from feeding with rotation exhibits a spool-like character that is consistent with experimental and previous theoretical work, whereas feeding without rotation results in a folded conformation inconsistent with a spool conformation. The chain segment density shows a layered structure, which is more pronounced for packaging with rotation. However, in both cases, the conformation is marked by frequent jumps of the polymer chain from layer to layer, potentially influencing the ability to disentangle during subsequent ejection. Ejection simulations with and without Brownian forces show that Brownian forces are necessary to achieve complete ejection of the polymer chain in the absence of external forces.

  3. Some in-field experiences of non-synchronous vibrations in large rotating machinery

    NASA Technical Reports Server (NTRS)

    Colnago, Giuseppe; Frigeri, Claudio; Vallini, Andrea; Zanetta, Gian Antonio

    1989-01-01

    Some problems associated with non-synchronous vibrations are analyzed by describing three cases experienced with fairly large rotating machines in operating conditions. In each case, a brief description is first given of the machine and of the instrumentation used. The experimental results are then presented, with reference to time or frequency domain recordings. The lines followed in diagnosis are then discussed and, lastly, the corrective action undertaken is presented.

  4. Spacetime Non-Commutativity Corrections to the Cardy-Verlinde Formula of Achúcarro-Ortiz Black Hole

    NASA Astrophysics Data System (ADS)

    Setare, M. R.

    2007-02-01

    In this letter we compute the corrections to the Cardy-Verlinde formula of Achúcarro-Ortiz black hole, which is the most general two-dimensional black hole derived from the three-dimensional rotating Banados-Teitelboim-Zanelli black hole. These corrections stem from the space non-commutativity. We show that in non-commutative case, non-rotating Achúcarro-Ortiz black hole in contrast with commutative case has two horizons.

  5. A Case Report of an Acromioclavicular Joint Ganglion Associated with a Rotator Cuff Tear.

    PubMed

    Tanaka, Suguru; Gotoh, Masafumi; Mitsui, Yasuhiro; Shirachi, Isao; Okawa, Takahiro; Higuchi, Fujio; Shiba, Naoto

    2017-04-13

    We report a case of subcutaneous ganglion adjacent to the acromioclavicular joint with massive rotator cuff tear [1-7]. An 81-year-old woman presented with a ganglion adjacent to the acromioclavicular joint that had first been identified 9 months earlier. The ganglion had recurred after having been aspirated by her local physician, so she was referred to our hospital. The puncture fluid was yellowish, clear and viscous. Magnetic resonance imaging identified a massive rotator cuff tear with multi- lobular cystic lesions continuous to the acromioclavicular joint, presenting the "geyser sign". During arthroscopy, distal clavicular resection and excision of the ganglion were performed together with joint debridement. At present, the ganglion has not recurred and the patient has returned to normal daily activity. In this case, the ganglion may have developed subsequent to the concomitant massive cuff tear, due to subcutaneous fluid flow through the damaged acromioclavicular joint.

  6. Dynamic Electrorheological Effects of Rotating Particles:

    NASA Astrophysics Data System (ADS)

    Yu, K. W.; Gu, G. Q.; Huang, J. P.; Xiao, J. J.

    Particle rotation leads to a steady-state which is different from the equilibrium state in the absence of rotational motion. The change of the polarization of the particle due to the rotational motion is called the dynamic electrorheological effect (DER). There are three cases to be considered: rotating particles in a dc field, particle rotation due to a rotating field and spontaneous rotation of particle in dc field (Quincke rotation). In the DER of rotating particles, the particle rotational motion generally reduces the interparticle force between the particles. The effect becomes pronounced when the frequency is on the order of the relaxation rate of the surface charges. In the electrorotation of particles, the mutual interaction between approaching particles will change the electrorotation spectrum significantly. The electrorotation spectrum depends strongly on the medium conductivity as well as the conductivity contrast between the particle and the medium. In the collective behaviors of Quincke rotors, the mutual interactions between the individual rotors lead to the assembly of chain-like structures which make an angle with the applied field. This has an implication of a new class of material.

  7. Traversing probe system

    DOEpatents

    Mashburn, Douglas N.; Stevens, Richard H.; Woodall, Harold C.

    1977-01-01

    This invention comprises a rotatable annular probe-positioner which carries at least one radially disposed sensing probe, such as a Pitot tube having a right-angled tip. The positioner can be coaxially and rotatably mounted within a compressor casing or the like and then actuated to orient the sensing probe as required to make measurements at selected stations in the annulus between the positioner and compressor casing. The positioner can be actuated to (a) selectively move the probe along its own axis, (b) adjust the yaw angle of the right-angled probe tip, and (c) revolve the probe about the axis common to the positioner and casing. A cam plate engages a cam-follower portion of the probe and normally rotates with the positioner. The positioner includes a first-motor-driven ring gear which effects slidable movement of the probe by rotating the positioner at a time when an external pneumatic cylinder is actuated to engage the cam plate and hold it stationary. When the pneumatic cylinder is not actuated, this ring gear can be driven to revolve the positioner and thus the probe to a desired circumferential location about the above-mentioned common axis. A second motor-driven ring gear included in the positioner can be driven to rotate the probe about its axis, thus adjusting the yaw angle of the probe tip. The positioner can be used in highly corrosive atmosphere, such as gaseous uranium hexafluoride.

  8. Two-View Gravity Stress Imaging Protocol for Nondisplaced Type II Supination External Rotation Ankle Fractures: Introducing the Gravity Stress Cross-Table Lateral View.

    PubMed

    Boffeli, Troy J; Collier, Rachel C; Gervais, Samuel J

    Assessing ankle stability in nondisplaced Lauge-Hansen supination external rotation type II injuries requires stress imaging. Gravity stress mortise imaging is routinely used as an alternative to manual stress imaging to assess deltoid integrity with the goal of differentiating type II from type IV injuries in cases without a posterior or medial fracture. A type II injury with a nondisplaced fibula fracture is typically treated with cast immobilization, and a type IV injury is considered unstable and often requires operative repair. The present case series (two patients) highlights a standardized 2-view gravity stress imaging protocol and introduces the gravity stress cross-table lateral view. The gravity stress cross-table lateral view provides a more thorough evaluation of the posterior malleolus owing to the slight external rotation and posteriorly directed stress. External rotation also creates less bony overlap between the tibia and fibula, allowing for better visualization of the fibula fracture. Gravity stress imaging confirmed medial-sided injury in both cases, confirming the presence of supination external rotation type IV or bimalleolar equivalent fractures. Open reduction and internal fixation was performed, and both patients achieved radiographic union. No further treatment was required at 21 and 33 months postoperatively. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Visual Vestibular Interaction in the Dynamic Visual Acuity Test during Voluntary Head Rotation

    NASA Technical Reports Server (NTRS)

    Lee, Moo Hoon; Durnford, Simon; Crowley, John; Rupert, Angus

    1996-01-01

    Although intact vestibular function is essential in maintaining spatial orientation, no good screening tests of vestibular function are available to the aviation community. High frequency voluntary head rotation was selected as a vestibular stimulus to isolate the vestibulo-ocular reflex (VOR) from visual influence. A dynamic visual acuity test that incorporates voluntary head rotation was evaluated as a potential vestibular function screening tool. Twenty-seven normal subjects performed voluntary sinusoidal head rotation at frequencies from 0.7-4.0 Hz under three different visual conditions: visually-enhanced VOR, normal VOR, and visually suppressed VOR. Standardized Baily-Lovie chart letters were presented on a computer monitor in front of the subject, who then was asked to read the letters while rotating his head horizontally. The electro-oculogram and dynamic visual acuity score were recorded and analyzed. There were no significant differences in gain or phase shift among three visual conditions in the frequency range of 2.8 to 4.0 Hz. The dynamic visual acuity score shifted less than 0.3 logMAR at frequencies under 2.0 Hz. The dynamic visual acuity test at frequencies a round 2.0 Hz can be recommended for evaluating vestibular function.

  10. Inflight source noise of an advanced full-scale single-rotation propeller

    NASA Technical Reports Server (NTRS)

    Woodward, Richard P.; Loeffler, Irvin J.

    1991-01-01

    Flight tests to define the far field tone source at cruise conditions were completed on the full scale SR-7L advanced turboprop which was installed on the left wing of a Gulfstream II aircraft. This program, designated Propfan Test Assessment (PTA), involved aeroacoustic testing of the propeller over a range of test conditions. These measurements defined source levels for input into long distance propagation models to predict en route noise. Inflight data were taken for 7 test cases. The sideline directivities measured by the Learjet showed expected maximum levels near 105 degrees from the propeller upstream axis. However, azimuthal directivities based on the maximum observed sideline tone levels showed highest levels below the aircraft. An investigation of the effect of propeller tip speed showed that the tone level of reduction associated with reductions in propeller tip speed is more significant in the horizontal plane than below the aircraft.

  11. Simplified analysis of a generalized bias test for fabrics with two families of inextensible fibres

    NASA Astrophysics Data System (ADS)

    Cuomo, M.; dell'Isola, F.; Greco, L.

    2016-06-01

    Two tests for woven fabrics with orthogonal fibres are examined using simplified kinematic assumptions. The aim is to analyse how different constitutive assumptions may affect the response of the specimen. The fibres are considered inextensible, and the kinematics of 2D continua with inextensible chords due to Rivlin is adopted. In addition to two forms of strain energy depending on the shear deformation, also two forms of energy depending on the gradient of shear are examined. It is shown that this energy can account for the bending of the fibres. In addition to the standard bias extension test, a modified test has been examined, in which the head of the specimen is rotated rather than translated. In this case more bending occurs, so that the results of the simulation carried out with the different energy models adopted differ more that what has been found for the BE test.

  12. Correcting a Widespread Error concerning the Angular Velocity of a Rotating Rigid Body.

    ERIC Educational Resources Information Center

    Leubner, C.

    1981-01-01

    Since many texts use an incorrect argument in obtaining the instantaneous velocity of a rotating body, a correct and concise derivation of this quantity for a rather general case is given. (Author/SK)

  13. Dizziness and Head Injury

    PubMed Central

    Barber, H. O.

    1965-01-01

    Dizziness, whether vague or specifically rotational, is a common sequel to head injury, and is often postural. One hundred and sixty-five patients with this symptom were examined. The simple posture tests employed to detect positional nystagmus are described. This physical finding was present in one-quarter of the entire group, and in nearly one-half of cases of longitudinal fracture of temporal bone. In such cases, it is an objective finding that corresponds precisely to the patient's complaint of vertigo. Transverse fracture of temporal bone destroys the inner ear in both cochlear and vestibular parts. Longitudinal fracture is commoner and causes bleeding from the ear; inner-ear damage is usually minor. In the rare cases where persisting postural vertigo and positional nystagmus are disabling, relief of the symptom may be achieved by vestibular denervation of the affected side. PMID:14285289

  14. Variational energy principle for compressible, baroclinic flow. 1: First and second variations of total kinetic action

    NASA Technical Reports Server (NTRS)

    Schmid, L. A.

    1977-01-01

    The case of a cold gas in the absence of external force fields is considered. Since the only energy involved is kinetic energy, the total kinetic action (i.e., the space-time integral of the kinetic energy density) should serve as the total free-energy functional in this case, and as such should be a local minimum for all possible fluctuations about stable flow. This conjecture is tested by calculating explicit, manifestly covariant expressions for the first and second variations of the total kinetic action in the context of Lagrangian kinematics. The general question of the correlation between physical stability and the convexity of any action integral that can be interpreted as the total free-energy functional of the flow is discussed and illustrated for the cases of rectillinear and rotating shearing flows.

  15. Open cycle ocean thermal energy conversion steam control and bypass system

    DOEpatents

    Wittig, J. Michael; Jennings, Stephen J.

    1980-01-01

    Two sets of hinged control doors for regulating motive steam flow from an evaporator to a condenser alternatively through a set of turbine blades in a steam bypass around the turbine blades. The evaporator has a toroidal shaped casing situated about the turbine's vertical axis of rotation and an outlet opening therein for discharging motive steam into an annular steam flow path defined between the turbine's radially inner and outer casing structures. The turbine blades extend across the steam flow path intermediate the evaporator and condenser. The first set of control doors is arranged to prevent steam access to the upstream side of the turbine blades and the second set of control doors acts as a bypass around the blades so as to maintain equilibrium between the evaporator and condenser during non-rotation of the turbine. The first set of control doors preferably extend, when closed, between the evaporator casing and the turbine's outer casing and, when open, extend away from the axis of rotation. The second set of control doors preferably constitute a portion of the turbine's outer casing downstream from the blades when closed and extend, when open, toward the axis of rotation. The first and second sets of control doors are normally held in the open and closed positions respectively by locking pins which may be retracted upon detecting an abnormal operating condition respectively to permit their closing and opening and provide steam flow from the evaporator to the condenser.

  16. Is subscapularis recruited in a similar manner during shoulder internal rotation exercises and belly press and lift off tests?

    PubMed

    Ginn, Karen A; Reed, Darren; Jones, Chelsea; Downes, Anthony; Cathers, Ian; Halaki, Mark

    2017-06-01

    Although the belly press and lift off tests are recommended to assess subscapularis function, shoulder internal rotation (IR) exercises performed in other shoulder positions are more commonly used to restore subscapularis function. It is not known if shoulder IR exercises specifically activate subscapularis to the same degree as the lift off and belly press tests, and thus have the potential to effect subscapularis strength gains. Therefore, the aim was to compare subscapularis activation levels with those of other shoulder internal rotator muscles during the belly press and lift off tests and shoulder IR exercise positions. Original research. Twenty asymptomatic volunteers performed maximal isometric contractions during the belly press and lift off tests and shoulder IR performed at 90° and 0° abduction in an upright position and supported at 90° abduction in supine. Muscle activation levels were recorded using a combination of indwelling and surface electrodes. Data were normalized to maximum voluntary contractions and averaged. Moderate average subscapularis activation levels were recorded during all shoulder IR tasks examined with no significant difference between tasks (p=0.18). The belly press test was the only IR task in which subscapularis activation levels were significantly higher than all other shoulder internal rotator muscles (p<0.05). Shoulder IR exercises activate subscapularis to similar moderate levels as the belly press and lift off tests and therefore, have similar potential to strengthen subscapularis. However, the belly press test, with significantly higher subscapularis activation than other shoulder internal rotators, more specifically targets subscapularis. Copyright © 2016. Published by Elsevier Ltd.

  17. Dissolution of steroid crystals in a nematic droplet: effect of rotation

    NASA Astrophysics Data System (ADS)

    Gvozdovskyy, I. A.; Terenetskaya, Irina P.; Reshetnyak, Victor Y.

    2003-12-01

    The nematic liquid crystals (LCs) can be converted into cholesteric LCs by different chiral dopants. For the first time the dynamics of a cholesteric phase induction was investigated on dissolution of the single steroid crystal (vitamin D isomers and relative compounds) at the nematic droplet and the new effect of the crystal rotation has been discovered. In all cases the correlation between the rotation direction and screw sense of the cholesteric helix was found. A theoretical model and interpretation of the rotation effect has been proposed.

  18. Spectroscopic line parameters of NH3 and PH3 in the far infrared

    NASA Technical Reports Server (NTRS)

    Husson, N.; Goldman, A.; Orton, G.

    1982-01-01

    NH3 and PH3 rotation and rotation-inversion line parameters in the far to medium IR are calculated for remote sounding purposes of planetary atmospheres; 1607 lines of (N-14)H3, 362 lines of (N-15)H3 and 325 lines of PH3 are compiled. The absolute intensity formulation has been reviewed in the case of rotation and rotation-inversion lines of molecules with C(3v) symmetry. The justification for the general agreement between the authors, and comparisons with other published expressions are given.

  19. The Maximum Mass of Rotating Strange Stars

    NASA Astrophysics Data System (ADS)

    Szkudlarek, M.; Gondek-Rosiń; ska, D.; Villain, L.; Ansorg, M.

    2012-12-01

    Strange quark stars are considered as a possible alternative to neutron stars as compact objects (e.g. Weber 2003). A hot compact star (a proto-neutron star or a strange star) born in a supernova explosion or a remnant of neutron stars binary merger are expected to rotate differentially and be important sources of gravitational waves. We present results of the first relativistic calculations of differentially rotating strange quark stars for broad ranges of degree of differential rotation and maximum densities. Using a highly accurate, relativistic code we show that rotation may cause a significant increase of maximum allowed mass of strange stars, much larger than in the case of neutron stars with the same degree of differential rotation. Depending on the maximum allowed mass a massive neutron star (strange star) can be temporarily stabilized by differential rotation or collapse to a black hole.

  20. Effect of steady crucible rotation on the segregation of impurities in vertical Bridgman growth of multi-crystalline silicon

    NASA Astrophysics Data System (ADS)

    Bellmann, M. P.; Meese, E. A.

    2011-10-01

    We have performed axisymmetric, transient simulations of the vertical Bridgman growth of multi-crystalline (mc) silicon to study the effect of the steady crucible rotation on the melt flow and impurity segregation. A solute transport model has been applied to predict the final segregation pattern of impurities in a circular ingot. Imposing rotation rates of 1-5 rpm on the system makes radial segregation much worse compared to the non-rotating case. Low rotation rates at 1-2 rpm increase radial segregation in the first half period of solidification, whereas at rotation rates above the effect is insignificantly small. Contrary behavior was observed for the second half period of solidification. Here radial segregation is increased at high rotation rates from 3 to 5 rpm with small impact at 1-2 rpm.

  1. Impacts of crop rotations on soil organic carbon sequestration

    NASA Astrophysics Data System (ADS)

    Gobin, Anne; Vos, Johan; Joris, Ingeborg; Van De Vreken, Philippe

    2013-04-01

    Agricultural land use and crop rotations can greatly affect the amount of carbon sequestered in the soil. We developed a framework for modelling the impacts of crop rotations on soil carbon sequestration at the field scale with test case Flanders. A crop rotation geo-database was constructed covering 10 years of crop rotation in Flanders using the IACS parcel registration (Integrated Administration and Control System) to elicit the most common crop rotation on major soil types in Flanders. In order to simulate the impact of crop cover on carbon sequestration, the Roth-C model was adapted to Flanders' environment and coupled to common crop rotations extracted from the IACS geodatabases and statistical databases on crop yield. Crop allometric models were used to calculate crop residues from common crops in Flanders and subsequently derive stable organic matter fluxes to the soil (REGSOM). The REGSOM model was coupled to Roth-C model was run for 30 years and for all combinations of seven main arable crops, two common catch crops and two common dosages of organic manure. The common crops are winter wheat, winter barley, sugar beet, potato, grain maize, silage maize and winter rapeseed; the catch crops are yellow mustard and Italian ryegrass; the manure dosages are 35 ton/ha cattle slurry and 22 ton/ha pig slurry. Four common soils were simulated: sand, loam, sandy loam and clay. In total more than 2.4 million simulations were made with monthly output of carbon content for 30 years. Results demonstrate that crop cover dynamics influence carbon sequestration for a very large percentage. For the same rotations carbon sequestration is highest on clay soils and lowest on sandy soils. Crop residues of grain maize and winter wheat followed by catch crops contribute largely to the total carbon sequestered. This implies that agricultural policies that impact on agricultural land management influence soil carbon sequestration for a large percentage. The framework is therefore suited for further scenario analysis and impact assessment in order to support agri-environmental policy decisions.

  2. Arthroscopic modified Mason-Allen technique for large U- or L-shaped rotator cuff tears.

    PubMed

    Jung, Sung-Weon; Kim, Dong-Hee; Kang, Seung-Hoon; Lee, Ji-Heon

    2017-07-01

    While a conventional single- or double-row repair technique could be applied for repair of C-shaped tears, a different surgical strategy should be considered for repair of U- or L-shaped tears because they typically have complex patterns with anterior, posterior, or both mobile leaves. This study was performed to examine the outcomes of the modified Mason-Allen technique for footprint restoration in the treatment of large U- or L-shaped rotator cuff tears. Thirty-two patients who underwent an arthroscopic modified Mason-Allen technique for large U- or L-shaped rotator cuff tears between January 2012 and December 2013 were included in this study. Margin convergence was first performed to reduce the tear gap and tension, and then, an arthroscopic Mason-Allen technique was performed to restore the rotator cuff footprint in a side-to-end repair fashion. All patients were evaluated preoperatively and for a minimum of 2 years of follow-up with a visual analog scale (VAS) for pain, Constant score, and ultrasonography. There was significant improvement in all VAS and Constant scores compared with the preoperative values (P < 0.001). Functional results by Constant scores included 9 cases that were classified as excellent, 11 cases as good, 8 cases as fair, and 2 cases as poor. Binary logistic regression analysis revealed that heavy work, pseudoparalysis, joint space narrowing, fatty degeneration of the SST and IST, and a positive tangent sign were found to significantly correlate with functional outcomes. Multivariable logistic regression analysis revealed that only fatty degeneration of the SST was a risk factor for fair/poor clinical outcomes. Complications occurred in 5 of the 32 patients (15.6 %), and the reoperation rate due to complications was 6.3 % (2 of 32 patients). An arthroscopic modified Mason-Allen technique was sufficient to restore the footprint of the rotator cuff in our data. Overall satisfactory results were achieved in most patients, with the exception of those with severe fatty degeneration. An arthroscopic modified Mason-Allen technique could be an effective and reliable alternative for patients with large U- or L-shaped rotator cuff tears. Case Series, Therapeutic Level IV.

  3. Stress induced near fault-zone breakout rotation: Two case studies in TCDP and JFAST

    NASA Astrophysics Data System (ADS)

    Wu, H. Y.; Brodsky, E. E.; Moe, K.; Kinoshita, M.

    2014-12-01

    Within the past decade, two successful rapid-response drilling projects have measured breakouts within the nearfault of a recently ruptured fault. Breakout observation is the direct way to detect the far and near filed stress orientation in drilling. Here we compare those data. In 2006, ICDP performed an inland drilling project to penetrate Chelungpu fault plane in central of Taiwan, which had recently slipped in 1999 Mw 7.6 Chi-Chi earthquake. This drilling project succeeded in full coring and collecting comprehensive logging data in the borehole. The resistivity images run by Formation Micro Imager (FMI) indicated that a breakout rotation in the vicinity of the fault (1111mbf). Leak-off tests on site constrained the magnitude of minimum horizontal principal stress. Here we use these data to determine the stress variation in the fault plane in our breakout dislocation model. Based on the amount of breakout azimuth, rotation and fault geometry, the stress drop can be estimated in this model. In 2012, IODP initiated a rapid drilling project after the 2011 Mw9.0 Tohoku earthquake in Japan Trench. Due to the deep-water depth, only a real-time resistivity image recorded by Logging While Drilling (LWD) and few core samples are recovered by this expedition. However, the breakout azimuth occurred near the plate boundary (820mbsf) represents the stress disturbance after the dramatic slip comparing to TCDP case. In this research, we are attempting to discuss the possible effect factors and reconstruct the geo-mechanical models to interpret the breakout distribution observed from logging data and the stress state after these huge earthquakes.

  4. Reverse shoulder arthroplasty for deltoid-deficient shoulder following latissimus dorsi flap transfer. Case report.

    PubMed

    Dosari, Mohamed Al Ateeq Al; Hameed, Shamsi; Mukhtar, Khalid; Elmhiregh, Aissam

    2017-01-01

    The usual indication for reverse shoulder arthroplasty is glenohumeral arthritis with inadequate rotator cuff and intact deltoid muscle. We report here a case of reverse shoulder arthroplasty using a lattisimus dorsi flap in a patient with deltoid-deficient shoulder following a gunshot injury. The patient was an otherwise healthy 51-year-old male with a history of gunshot injury of the left shoulder 2006. Upon presentation in 2011, the patient had a loss of most of his shoulder bony and muscular structures. Due to deltoid muscle deficiency, the patient underwent Lattisimus Dorsi muscle flap followed by reverse shoulder arthroplasty in order to establish an upper limb function. Upon discharge, 11days after the surgery, the patient was able to achieve 150° flexion and 90° abduction while in the supine position and 45° in each direction, while sitting. He was able to perform internal rotation (behind back) up to the level of the L1 vertebra, assisted active abduction of 90°, and external rotation of 20°. Power tests showed power of grade 4/5 for both shoulder flexion and extension and grade 2+/5 for both abduction and adduction. At the last follow up one year after the operation, The patient still had passive pain-free full range of motion, but no progress in active range of motion beyond that upon discharge. Reverse shoulder arthroplasty after Latissmus dori flap in patient with deltoid deficient shoulders can be a successful and reproducible approach to treat such conditions. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. Posterior axilla sling traction for shoulder dystocia: case review and a new method of shoulder rotation with the sling.

    PubMed

    Cluver, Catherine Anne; Hofmeyr, G Justus

    2015-06-01

    The purpose of this study was to report on all cases in which posterior axilla sling traction (PAST) has been used to deliver cases of intractable shoulder dystocia and to describe a new method of shoulder rotation with the sling. A record of all published and known cases was collected that included information on preliminary obstetric techniques that were used and how the PAST technique was performed. Maternal outcomes that included maternal injury and length of hospital stay and fetal outcomes, which included birthweight, Apgar scores, nerve injuries, fractures, hospital stay, and outcome, were documented. We have recorded 19 cases where PAST has been used. In 5 cases, the babies had died in utero. Ten were assisted deliveries. PAST was successful in 18 cases. In one case, it was partially successful because it enabled delivery of the posterior shoulder with digital axillary traction. The most commonly used material was suction tubing. Once the posterior shoulder was delivered, the shoulder dystocia was resolved in all cases. Time from insertion to delivery was <3 minutes when recorded. The birthweights of the infants varied from 3200-4800 g. Posterior arm humerus fractures occurred in 3 cases. There was one case of a permanent Erb's palsy and 4 cases of transient Erb's palsies. None were of the posterior arm. During this review, we found that, when direct delivery of the posterior shoulder was difficult because of very severe impaction, the sling could be used to rotate the shoulders easily through 180 degrees assisted by counter pressure on the back of the anterior shoulder. This new method was used in 5 cases and may reduce fetal trauma further during difficult shoulder delivery. This review confirms that PAST can be a lifesaving technique when all another techniques for shoulder dystocia fail. Advantages are that it is easy to use (even by someone who has not seen it used previously), that the sling material is readily available, and that it is inserted quickly with 2 fingers. This is the first report of its use to rotate the posterior shoulder to the anterior position for delivery. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. The Unruh effect for eccentric uniformly rotating observers

    NASA Astrophysics Data System (ADS)

    Ramezani-Aval, H.

    It is common to use Galilean rotational transformation (GRT) to investigate the Unruh effect for uniformly rotating observers. However, the rotating observer in this subject is an eccentric observer while GRT is only valid for centrally rotating observers. Thus, the reliability of the results of applying GRT to the study of the Unruh effect might be considered as questionable. In this work, the rotational analog of the Unruh effect is investigated by employing two relativistic rotational transformations corresponding to the eccentric rotating observer, and it is shown that in both cases, the detector response function is nonzero. It is also shown that although consecutive Lorentz transformations cannot give a frame within which the canonical construction can be carried out, the expectation value of particle number operator in canonical approach will be zero if we use modified Franklin transformation. These conclusions reinforce the claim that correspondence between vacuum states defined via canonical field theory and a detector is broken for rotating observers. Some previous conclusions are commented on and some controversies are also discussed.

  7. Effects of humeral head compression taping on the isokinetic strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis.

    PubMed

    Kim, Moon-Hwan; Oh, Jae-Seop

    2015-01-01

    [Purpose] The purpose of this study was to examine the effects of humeral head compression taping (HHCT) on the strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis. [Subjects and Methods] Twenty patients with rotator cuff tendinitis were recruited. The shoulder external rotator strength was measured using a Biodex isokinetic dynamometer system. A paired t-test was performed to evaluate within-group differences in the strength of the shoulder external rotator muscle. [Results] Significantly higher shoulder external rotator peak torque and peak torque per body weight were found in the HHCT condition than in the no-taping condition. [Conclusion] HHCT may effectively increase the shoulder external rotator muscle strength in patients with rotator cuff tendinitis.

  8. Absence of sex differences in mental rotation performance in autism spectrum disorder.

    PubMed

    Rohde, Melanie S; Georgescu, Alexandra L; Vogeley, Kai; Fimmers, Rolf; Falter-Wagner, Christine M

    2017-08-01

    Mental rotation is one of the most investigated cognitive functions showing consistent sex differences. The 'Extreme Male Brain' hypothesis attributes the cognitive profile of individuals with autism spectrum disorder to an extreme version of the male cognitive profile. Previous investigations focused almost exclusively on males with autism spectrum disorder with only limited implications for affected females. This study is the first testing a sample of 12 female adults with high-functioning autism spectrum disorder compared to 14 males with autism spectrum disorder, 12 typically developing females and 14 typically developing males employing a computerised version of the mental rotation test. Reaction time and accuracy served as dependent variables. Their linear relationship with degree of rotation allows separation of rotational aspects of the task, indicated by slopes of the psychometric function, and non-rotational aspects, indicated by intercepts of the psychometric function. While the typical and expected sex difference for rotational task aspects was corroborated in typically developing individuals, no comparable sex difference was found in autism spectrum disorder individuals. Autism spectrum disorder and typically developing individuals did not differ in mental rotation performance. This finding does not support the extreme male brain hypothesis of autism.

  9. Homogeneous wave turbulence driven by tidal flows

    NASA Astrophysics Data System (ADS)

    Favier, B.; Le Reun, T.; Barker, A.; Le Bars, M.

    2017-12-01

    When a moon orbits around a planet, the rotation of the induced tidal bulge drives a homogeneous, periodic, large-scale flow. The combination of such an excitation with the rotating motion of the planet has been shown to drive parametric resonance of a pair of inertial waves in a mechanism called the elliptical instability. Geophysical fluid layers can also be stratified: this is the case for instance of the Earth's oceans and, as suggested by several studies, of the upper part of the Earth's liquid Outer Core. We thus investigate the stability of a rotating and stratified layer undergoing tidal distortion in the limit where either rotation or stratification is dominant. We show that the periodic tidal flow drives a parametric subharmonic resonance of inertial (resp. internal) waves in the rotating (resp. stratified) case. The instability saturates into a wave turbulence pervading the whole fluid layer. In such a state, the instability mechanism conveys the tidal energy from the large scale tidal flow to the resonant modes, which then feed a succession of triadic resonances also generating small spatial scales. In the rotating case, we observe a kinetic energy spectrum with a k-2 slope for which the Coriolis force is dominant at all spatial scales. In the stratified case, where the timescale separation is increased between the tidal excitation and the Brunt-Väisälä frequencies, the temporal spectrum decays with a ω-2 power law up to the cut-off frequency beyond which waves do not exist. This result is reminiscent of the Garrett and Munk spectrum measured in the oceans and theoretically described as a manifestation of internal wave turbulence. In addition to revealing an instability driving homogeneous turbulence in geophysical fluid layers, our approach is also an efficient numerical tool to investigate the possibly universal properties of wave turbulence in a geophysical context.

  10. Rotation of vertically oriented objects during earthquakes

    NASA Astrophysics Data System (ADS)

    Hinzen, Klaus-G.

    2012-10-01

    Vertically oriented objects, such as tombstones, monuments, columns, and stone lanterns, are often observed to shift and rotate during earthquake ground motion. Such observations are usually limited to the mesoseismal zone. Whether near-field rotational ground motion components are necessary in addition to pure translational movements to explain the observed rotations is an open question. We summarize rotation data from seven earthquakes between 1925 and 2009 and perform analog and numeric rotation testing with vertically oriented objects. The free-rocking motion of a marble block on a sliding table is disturbed by a pulse in the direction orthogonal to the rocking motion. When the impulse is sufficiently strong and occurs at the `right' moment, it induces significant rotation of the block. Numeric experiments of a free-rocking block show that the initiation of vertical block rotation by a cycloidal acceleration pulse applied orthogonal to the rocking axis depends on the amplitude of the pulse and its phase relation to the rocking cycle. Rotation occurs when the pulse acceleration exceeds the threshold necessary to provoke rocking of a resting block, and the rocking block approaches its equilibrium position. Experiments with blocks subjected to full 3D strong motion signals measured during the 2009 L'Aquila earthquake confirm the observations from the tests with analytic ground motions. Significant differences in the rotational behavior of a monolithic block and two stacked blocks exist.

  11. The effect of different screw-rod design on the anti-rotational torque: a biomechanical comparison of three conventional screw-rod constructs.

    PubMed

    Huang, Zifang; Wang, Chongwen; Fan, Hengwei; Sui, Wenyuan; Li, Xueshi; Wang, Qifei; Yang, Junlin

    2017-07-28

    Screw-rod constructs have been widely used to correct spinal deformities, but the effects of different screw-rod systems on anti-rotational torque have not been determined. This study aimed to analyze the biomechanical effect of different rod-screw constructs on anti-rotational torque. Three conventional spinal screw-rod systems (Legacy, RF-F-10 and USSII) were used to test the anti-rotational torque in the material test machine. ANOVA was performed to evaluate the anti-rotational capacity of different pedicle screws-rod constructs. The anti-rotational torque of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm, with a P value lower than 0.05. This results indicated that the Legacy screws-rod construct could provide a highest anti-rotation capacity, which is 68% and 210% greater than RF-F-10 screw-rod construct and USSII screw-rod respectively. The anti-rotational torque may be mainly affected by screw cap and groove design. Our result showed the anti-rotational torque are: Legacy system > RF-F-10 system > USSII system, suggesting that appropriate rod-screw constructs selection in surgery may be vital for anti-rotational torque improvement and preventing derotation correction loss.

  12. Descriptive profile of hip rotation range of motion in elite tennis players and professional baseball pitchers.

    PubMed

    Ellenbecker, Todd S; Ellenbecker, Gail A; Roetert, E Paul; Silva, Rogerio Teixeira; Keuter, Greg; Sperling, Fabio

    2007-08-01

    Repetitive loading to the hip joint in athletes has been reported as a factor in the development of degenerative joint disease and intra-articular injury. Little information is available on the bilateral symmetry of hip rotational measures in unilaterally dominant upper extremity athletes. Side-to-side differences in hip joint range of motion may be present because of asymmetrical loading in the lower extremities of elite tennis players and professional baseball pitchers. Cohort (cross-sectional) study (prevalence); Level of evidence, 1. Descriptive measures of hip internal and external rotation active range of motion were taken in the prone position of 64 male and 83 female elite tennis players and 101 male professional baseball pitchers using digital photos and computerized angle calculation software. Bilateral differences in active range of motion between the dominant and nondominant hip were compared using paired t tests and Bonferroni correction for hip internal, external, and total rotation range of motion. A Pearson correlation test was used to test the relationship between years of competition and hip rotation active range of motion. No significant bilateral difference (P > .005) was measured for mean hip internal or external rotation for the elite tennis players or the professional baseball pitchers. An analysis of the number of subjects in each group with a bilateral difference in hip rotation greater than 10 degrees identified 17% of the professional baseball pitchers with internal rotation differences and 42% with external rotation differences. Differences in the elite male tennis players occurred in only 15% of the players for internal rotation and 9% in external rotation. Female subjects had differences in 8% and 12% of the players for internal and external rotation, respectively. Statistical differences were found between the mean total arc of hip range of internal and external rotation in the elite tennis players with the dominant side being greater by a clinically insignificant mean value of 2.5 degrees. Significantly less (P < .005) dominant hip internal rotation and less dominant and nondominant hip total rotation range of motion were found in the professional baseball pitchers compared with the elite male tennis players. This study established typical range of motion patterns and identified bilaterally symmetric hip active range of motion rotation values in elite tennis players and professional baseball pitchers. Asymmetric hip joint rotational active range of motion encountered during clinical examination and screening may indicate abnormalities and would indicate the application of flexibility training, rehabilitation, and further evaluation.

  13. Benchmarking in a differentially heated rotating annulus experiment: Multiple equilibria in the light of laboratory experiments and simulations

    NASA Astrophysics Data System (ADS)

    Vincze, Miklos; Harlander, Uwe; Borchert, Sebastian; Achatz, Ulrich; Baumann, Martin; Egbers, Christoph; Fröhlich, Jochen; Hertel, Claudia; Heuveline, Vincent; Hickel, Stefan; von Larcher, Thomas; Remmler, Sebastian

    2014-05-01

    In the framework of the German Science Foundation's (DFG) priority program 'MetStröm' various laboratory experiments have been carried out in a differentially heated rotating annulus configuration in order to test, validate and tune numerical methods to be used for modeling large-scale atmospheric processes. This classic experimental set-up is well known since the late 1940s and is a widely studied minimal model of the general mid-latitude atmospheric circulation. The two most relevant factors of cyclogenesis, namely rotation and meridional temperature gradient are quite well captured in this simple arrangement. The tabletop-size rotating tank is divided into three sections by coaxial cylindrical sidewalls. The innermost section is cooled whereas the outermost annular cavity is heated, therefore the working fluid (de-ionized water) in the middle annular section experiences differential heat flow, which imposes thermal (density) stratification on the fluid. At high enough rotation rates the isothermal surfaces tilt, leading to baroclinic instability. The extra potential energy stored in this unstable configuration is then converted into kinetic energy, exciting drifting wave patterns of temperature and momentum anomalies. The signatures of these baroclinic waves at the free water surface have been analysed via infrared thermography in a wide range of rotation rates (keeping the radial temperature difference constant) and under different initial conditions (namely, initial spin-up and "spin-down"). Paralelly to the laboratory simulations of BTU Cottbus-Senftenberg, five other groups from the MetStröm collaboration have conducted simulations in the same parameter regime using different numerical approaches and solvers, and applying different initial conditions and perturbations for stability analysis. The obtained baroclinic wave patterns have been evaluated via determining and comparing their Empirical Orthogonal Functions (EOFs), drift rates and dominant wave modes. Thus certain "benchmarks" have been created that can later be used as test cases for atmospheric numerical model validation. Both in the experiments and in the numerics multiple equilibrium states have been observed in the form of hysteretic behavior depending on the initial conditions. The precise quantification of these state and wave mode transitions may shed light to some aspects of the basic underlying dynamics of the baroclinic annulus configuration, still to be understood.

  14. Bifurcation of rotating liquid drops: Results from USML-1 experiments in space

    NASA Technical Reports Server (NTRS)

    Wang, Taylor G.; Anilkumar, A. V.; Lee, C. P.; Lin, K. C.

    1994-01-01

    Experiments on rotational bifurcation of liquid drops, in which the drops were levitated and spun using acoustic fields in a low-gravity environment, were conducted during the first United States Microgravity Laboratory (USML-1) Space Shuttle flight. The experiments have successfully resolved the discrepancies existing between the previous experimental results and the theoretical predictions. In the case of a spherical drop, for which theory exists, the results agree well with the predictions. In the case of flattened drops, the experiments have extablished a family of curves, with the spherical drop as the limiting case.

  15. Optimal Elevation and Configuration of Hanford's Double-Shell Tank Waste Mixer Pumps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Onishi, Yasuo; Yokuda, Satoru T.; Majumder, Catherine A.

    The objective of this study was to compare the mixing performance of the Lawrence pump, which has injection nozzles at the top, with an alternative pump that has injection nozzles at the bottom, and to determine the optimal elevation for the alternative pump. Sixteen cases were evaluated: two sludge thicknesses at eight levels. A two-step evaluation approach was used: Step 1 to evaluate all 16 cases with the non-rotating mixer pump model and Step 2 to further evaluate four of those cases with the more realistic rotating mixer pump model. The TEMPEST code was used.

  16. [Rotator cuff diseases in occupational medicine between occupational diseases and accidents: medical-legal considerations].

    PubMed

    Spigno, F; Galli, R; Casali, C; Lagattolla, N; De Lucchi, M

    2010-01-01

    The authors have gone through the complaints concerning all the cases of shoulder accidents at work filed by the Genoa office of the Italian Workers' National compensation Agency (INAIL) during the two years' period 2006-2007, reviewing in particular those somehow affecting rotator components. The aim of this paper is to assess the real role played by the occupational trauma in the rotator cuff tear. The data gathered so far have shown, on the one hand, a high prevalence of pre-existing inflammatory and degenerative diseases and, on the other, a rather modest influence of the trauma which, for this reason, has usually borne, as an immediate medico-legal consequence, the rejection of a cause-effect relationship between the accident and the rotator cuff lesion, without taking into any account whether the worker was likely to be affected by an occupational disease (ex table Ministerial Decree n. 81 April 9th 2008- item 78). In such cases a systematic and in-depth investigation of the occupational case history is suggested, in order to highlight the possible pre-existence of a former biomechanical overload of the upper limbs, so as to allow the physician to detect a pathology often misdiagnosed.

  17. Rotating shielded crane system

    DOEpatents

    Commander, John C.

    1988-01-01

    A rotating, radiation shielded crane system for use in a high radiation test cell, comprises a radiation shielding wall, a cylindrical ceiling made of radiation shielding material and a rotatable crane disposed above the ceiling. The ceiling rests on an annular ledge intergrally attached to the inner surface of the shielding wall. Removable plugs in the ceiling provide access for the crane from the top of the ceiling into the test cell. A seal is provided at the interface between the inner surface of the shielding wall and the ceiling.

  18. Stability Analysis for Rotating Stall Dynamics in Axial Flow Compressors

    DTIC Science & Technology

    1999-01-01

    modes determines collectively local stability of the compressor model. Explicit conditions are obtained for local stability of rotating stall which...critical modes determines the stability for rotating stall collectively . We point out that although in a special case our stability condition for...strict crossing assumption implies that the zero solution changes its stability as ~, crosses ~’c. For instance, odk (yc ) > 0 implies that the zero

  19. Vortices in a rotating two-component Bose–Einstein condensate with tunable interactions and harmonic potential

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Xiao-Fei, E-mail: xfzhang@ntsc.ac.cn; Du, Zhi-Jing; Tan, Ren-Bing

    We consider a pair of coupled nonlinear Schrödinger equations modeling a rotating two-component Bose–Einstein condensate with tunable interactions and harmonic potential, with emphasis on the structure of vortex states by varying the strength of inter-component interaction, rotational frequency, and the aspect ratio of the harmonic potential. Our results show that the inter-component interaction greatly enhances the effect of rotation. For the case of isotropic harmonic potential and small inter-component interaction, the initial vortex structure remains unchanged. As the ratio of inter- to intra-component interactions increases, each component undergoes a transition from a vortex lattice (vortex line) in an isotropic (anisotropic)more » harmonic potential to an alternatively arranged stripe pattern, and eventually to the interwoven “serpentine” vortex sheets. Moreover, in the case of anisotropic harmonic potential the system can develop to a rotating droplet structure. -- Highlights: •Different vortex structures are obtained within the full parameter space. •Effects of system parameters on the ground state structure are discussed. •Phase transition between different vortex structures is also examined. •Present one possible way to obtain the rotating droplet structure. •Provide many possibilities to manipulate vortex in two-component BEC.« less

  20. Generalization of Jacobi's Decomposition Theorem to the Rotation and Translation of a Solid in a Fluid.

    NASA Astrophysics Data System (ADS)

    Chiang, Rong-Chang

    Jacobi found that the rotation of a symmetrical heavy top about a fixed point is composed of the two torque -free rotations of two triaxial bodies about their centers of mass. His discovery rests on the fact that the orthogonal matrix which represents the rotation of a symmetrical heavy top is decomposed into a product of two orthogonal matrices, each of which represents the torque-free rotations of two triaxial bodies. This theorem is generalized to the Kirchhoff's case of the rotation and translation of a symmetrical solid in a fluid. This theorem requires the explicit computation, by means of theta functions, of the nine direction cosines between the rotating body axes and the fixed space axes. The addition theorem of theta functions makes it possible to decompose the rotational matrix into a product of similar matrices. This basic idea of utilizing the addition theorem is simple but the carry-through of the computation is quite involved and the full proof turns out to be a lengthy process of computing rather long and complex expressions. For the translational motion we give a new treatment. The position of the center of mass as a function of the time is found by a direct evaluation of the elliptic integral by means of a new theta interpretation of Legendre's reduction formula of the elliptic integral. For the complete solution of the problem we have added further the study of the physical aspects of the motion. Based on a complete examination of the all possible manifolds of the steady helical cases it is possible to obtain a full qualitative description of the motion. Many numerical examples and graphs are given to illustrate the rotation and translation of the solid in a fluid.

Top