  1. Limited rotation of the mobile-bearing in a rotating platform total knee prosthesis.

    PubMed

    Garling, E H; Kaptein, B L; Nelissen, R G H H; Valstar, E R

    2007-01-01

    The hypothesis of this study was that the polyethylene bearing in a rotating platform total knee prosthesis shows axial rotation during a step-up motion, thereby facilitating the theoretical advantages of mobile-bearing knee prostheses. We examined 10 patients with rheumatoid arthritis who had a rotating platform total knee arthroplasty (NexGen LPS mobile, Zimmer Inc. Warsaw, USA). Fluoroscopic data was collected during a step-up motion six months postoperatively. A 3D-2D model fitting technique was used to reconstruct the in vivo 3D kinematics. The femoral component showed more axial rotation than the polyethylene mobile-bearing insert compared to the tibia during extension. In eight knees, the femoral component rotated internally with respect to the tibia during extension. In the other two knees the femoral component rotated externally with respect to the tibia. In all 10 patients, the femur showed more axial rotation than the mobile-bearing insert indicating the femoral component was sliding on the polyethylene of the rotating platform during the step-up motion. Possible explanations are a too limited conformity between femoral component and insert, the anterior located pivot location of the investigated rotating platform design, polyethylene on metal impingement and fibrous tissue formation between the mobile-bearing insert and the tibial plateau.

  2. Late dislocation of rotating platform in New Jersey Low-Contact Stress knee prosthesis.

    PubMed

    Huang, Chun-Hsiung; Ma, Hon-Ming; Liau, Jiann-Jong; Ho, Fang-Yuan; Cheng, Cheng-Kung

    2002-12-01

    Five patients with late rotational dislocation of the rotating platform bearing in the New Jersey Low-Contact Stress total knee arthroplasty are reported. The prostheses had functioned well for 8 to 12 years before failure. Preoperative radiographs showed asymmetric femorotibial joint spaces. Entrapment of the dislocated bearing in three patients and spontaneous reduction of the dislocated bearing in another two patients were seen at revision. Femorotibial ligamentous instability was found after reduction. The retrieved polyethylene bearings showed advanced wear and cold flow deformities and the thickness was reduced. The revision arthroplasty was accomplished by replacement with a thicker bearing element. Progressive femorotibial ligament laxity and reduction of the thickness of polyethylene with wearing break down the originally well-balanced soft tissue tension of the knee. The rotational degree of the rotating platform bearing is unrestricted, which may result in late dislocation. Polyethylene wear is unavoidable in knee prostheses using metal contact with polyethylene even with a mobile-bearing design. Efforts to reduce polyethylene wear are mandatory.

  3. Improvement in the clinical practicability of roentgen stereophotogrammetric analysis (RSA): free from the use of the dual X-ray equipment.

    PubMed

    Shih, Kao-Shang; Lee, Chian-Her; Syu, Ci-Bin; Lai, Jiing-Yih; Chen, Kuo-Jen; Lin, Shang-Chih

    2012-10-01

    After total knee replacement, the monitoring of the prosthetic performance is often done by roentgenographic examination. However, the two-dimensional (2D) roentgen images only provide information about the projection onto the anteroposterior (AP) and mediolateral (ML) planes. Historically, the model-based roentgen stereophotogrammetric analysis (RSA) technique has been developed to predict the spatial relationship between prostheses by iteratively comparing the projective data for the prosthetic models and the roentgen images. During examination, the prosthetic poses should be stationary. This should be ensured, either by the use of dual synchronized X-ray equipment or by the use of a specific posture. In practice, these methods are uncommon or technically inconvenient during follow-up examination. This study aims to develop a rotation platform to improve the clinical applicability of the model-based RSA technique. The rotation platform allows the patient to assume a weight-bearing posture, while being steadily rotated so that both AP and ML knee images can be obtained. This study uses X-ray equipment with a single source and flat panel detectors (FPDs). Four tests are conducted to evaluate the quality of the FPD images, steadiness of the rotation platform, and accuracy of the RSA results. The results show that the distortion-induced error of the FPD image is quite minor, and the prosthetic size can be cautiously calibrated by means of the scale ball(s). The rotation platform should be placed closer to the FPD and orthogonal to the projection axis of the X-ray source. Image overlap of the prostheses can be avoided by adjusting both X-ray source and knee posture. The device-induced problems associated with the rotation platform include the steadiness of the platform operation and the balance of the rotated subject. Sawbone tests demonstrate that the outline error, due to the platform, is of the order of the image resolution (= 0.145 mm). In conclusion, the rotation platform with steady rotation, a knee support, and a handle can serve as an alternative method to take prosthetic images, without the loss in accuracy associated with the RSA method.

  4. Apparatus and method for materials processing utilizing a rotating magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muralidharan, Govindarajan; Angelini, Joseph A.; Murphy, Bart L.

    An apparatus for materials processing utilizing a rotating magnetic field comprises a platform for supporting a specimen, and a plurality of magnets underlying the platform. The plurality of magnets are configured for rotation about an axis of rotation intersecting the platform. A heat source is disposed above the platform for heating the specimen during the rotation of the plurality of magnets. A method for materials processing utilizing a rotating magnetic field comprises providing a specimen on a platform overlying a plurality of magnets; rotating the plurality of magnets about an axis of rotation intersecting the platform, thereby applying a rotatingmore » magnetic field to the specimen; and, while rotating the plurality of magnets, heating the specimen to a desired temperature.« less

  5. 10-year evaluation of the cementless low-contact- stress rotating-platform total knee arthroplasty.

    PubMed

    Efstathopoulos, Nikolaos; Mavrogenis, Andreas F; Lallos, Stergios; Nikolaou, Vassilios; Papagelopoulos, Panayiotis J; Savvidou, Olga D; Korres, Demetrios S

    2009-01-01

    We present the clinical and radiographic outcomes of the cementless low-contact-stress (LCS) rotating-platform total knee arthroplasty. Overall, 423 prostheses were implanted in 393 consecutive patients (30 patients had bilateral total knee replacement) for primary varus gonarthrosis (381 patients) and rheumatoid arthritis (12 patients). There were 81 men and 312 women with a mean age of 73 years (range, 58-85 years). Patella replacement was not performed in any case. Clinical and radiographic evaluation was performed using the Knee Society Score (KSS) and the Knee Society Assessment Form, respectively. The mean follow-up was 10 years (range, 5-15 years). Three patients were lost to follow-up. Survival of the prostheses was 98% at 10 years; three prostheses required revision for deep infection, bearing dislocation, and periprosthetic fracture. The mean KSS improved significantly, from 42 and 44 points preoperatively to 90 and 79 points, respectively, at the latest evaluation (P < 0.001); results were excellent in 278 cases, good in 106, fair in 27, and poor in nine. Radiolucent lines were observed in 80 cases; revision arthroplasty was not performed in any of these cases. Complications included deep infection in one patient, bearing dislocation in one, skin necrosis in four, and a supracondylar fracture in one. The cementless LCS rotating-platform total knee arthroplasty is associated with excellent mid- and long-term results for patients with osteoarthritis and rheumatoid arthritis of the knee.

  6. Increased risk of aseptic loosening for 43,525 rotating-platform vs. fixed-bearing total knee replacements

    PubMed Central

    Gothesen, Oystein; Lygre, Stein Hakon L; Lorimer, Michelle; Graves, Stephen; Furnes, Ove

    2017-01-01

    Background and purpose — Given similar functional outcomes with mobile and fixed bearings, a difference in survivorship may favor either. This study investigated the risk of aseptic loosening for the most used subtypes of mobile-bearing rotating-platform knees, in Norway and Australia. Patients and methods — Primary TKRs reported to the Norwegian and Australian joint registries, between 2003 and 2014, were analyzed with aseptic loosening as primary end-point and all revisions as secondary end-point. We hypothesized that no difference would be found in the rate of revision between rotating-platform and the most used fixed-bearing TKRs, or between keeled and non-keeled tibia. Kaplan–Meier estimates and curves, and Cox regression relative risk estimates adjusted for age, sex, and diagnosis were used for comparison. Results — The rotating-platform TKRs had an increased risk of revision for aseptic loosening compared with the most used fixed-bearing knees, in Norway (RR =6, 95% CI 4–8) and Australia (RR =2.1, 95% CI 1.8–2.5). The risk of aseptic loosening as a reason for revision was highest in Norway compared with Australia (RR =1.7, 95% CI 1.4–2.0). The keeled tibial component had the same risk of aseptic loosening as the non-keeled tibia (Australia). Fixation method and subtypes of the tibial components had no impact on the risk of aseptic loosening in these mobile-bearing knees. Interpretation — The rotating-platform TKRs in this study appeared to have a higher risk of revision for aseptic loosening than the most used fixed-bearing TKRs. PMID:28929828

  7. Comparison of the clinical outcomes after total knee arthroplasty with the LCS rotating platform mobile bearing knee system and the PFC Sigma RP-F mobile bearing knee system.

    PubMed

    Kwak, Ju-Yeong; Jeong, Jae-Heon; Lee, Sang-Hak; Jung, Ho-Joong; Jung, Young-Bok

    2012-12-01

    We compared clinical outcomes after total knee arthroplasty with the Low Contact Stress (LCS) rotating platform mobile bearing knee system and the Press Fit Condylar Sigma rotating platform high flexion (PFC Sigma RP-F) mobile bearing knee system. Fifty cases of total knee arthroplasty were performed with the PFC Sigma RP-F mobile bearing knee system and sixty-one cases were performed with the LCS mobile bearing total knee arthroplasty. The average duration of follow-up was 2.9 years. The mean Hospital for Special Surgery (HSS) knee score was 62.1 (range, 52 to 75) in the LCS group and 61.9 (range, 50 to 74) in the Sigma RP-F group preoperatively, and 90.1 (range, 84 to 100) in the LCS group and 89.8 (range, 83 to 100) in the Sigma RP-F group at the final follow-up. The mean preoperative flexion contracture was 6.7° (range, 0° to 10°) in the LCS group and 9.3° (range, 0° to 15°) in the Sigma RP-F group preoperatively. The mean range of motion was 124.6° (range, 105° to 150°) in the LCS group and 126.1° (range, 104° to 145°) in the Sigma RP-F group at the final follow-up. After a minimum duration of follow-up of two years, we found no significant differences between the two groups with regard to the range of knee motion or the clinical or radiographic results.

  8. Studies of superresolution range-Doppler imaging

    NASA Astrophysics Data System (ADS)

    Zhu, Zhaoda; Ye, Zhenru; Wu, Xiaoqing; Yin, Jun; She, Zhishun

    1993-02-01

    This paper presents three superresolution imaging methods, including the linear prediction data extrapolation DFT (LPDEDFT), the dynamic optimization linear least squares (DOLLS), and the Hopfield neural network nonlinear least squares (HNNNLS). Live data of a metalized scale model B-52 aircraft, mounted on a rotating platform in a microwave anechoic chamber, have in this way been processed, as has a flying Boeing-727 aircraft. The imaging results indicate that, compared to the conventional Fourier method, either higher resolution for the same effective bandwidth of transmitted signals and total rotation angle in imaging, or equal-quality images from smaller bandwidth and total rotation, angle may be obtained by these superresolution approaches. Moreover, these methods are compared in respect of their resolution capability and computational complexity.

  9. Silicon-on-insulator polarization splitting and rotating device for polarization diversity circuits.

    PubMed

    Liu, Liu; Ding, Yunhong; Yvind, Kresten; Hvam, Jørn M

    2011-06-20

    A compact and efficient polarization splitting and rotating device built on the silicon-on-insulator platform is introduced, which can be readily used for the interface section of a polarization diversity circuit. The device is compact, with a total length of a few tens of microns. It is also simple, consisting of only two parallel silicon-on-insulator wire waveguides with different widths, and thus requiring no additional and nonstandard fabrication steps. A total insertion loss of -0.6 dB and an extinction ratio of 12 dB have been obtained experimentally in the whole C-band.

  10. System for damping vibrations in a turbine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roberts, III, Herbert Chidsey; Johnson, Curtis Alan; Taxacher, Glenn Curtis

    2015-11-24

    A system for damping vibrations in a turbine includes a first rotating blade having a first ceramic airfoil, a first ceramic platform connected to the first ceramic airfoil, and a first root connected to the first ceramic platform. A second rotating blade adjacent to the first rotating blade includes a second ceramic airfoil, a second ceramic platform connected to the second ceramic airfoil, and a second root connected to the second ceramic platform. A non-metallic platform damper has a first position in simultaneous contact with the first and second ceramic platforms.

  11. A novel rotating experimental platform in a superconducting magnet.

    PubMed

    Chen, Da; Cao, Hui-Ling; Ye, Ya-Jing; Dong, Chen; Liu, Yong-Ming; Shang, Peng; Yin, Da-Chuan

    2016-08-01

    This paper introduces a novel platform designed to be used in a strong static magnetic field (in a superconducting magnet). The platform is a sample holder that rotates in the strong magnetic field. Any samples placed in the platform will rotate due to the rotation of the sample holder. With this platform, a number of experiments such as material processing, culture of biological systems, chemical reactions, or other processes can be carried out. In this report, we present some preliminary experiments (protein crystallization, cell culture, and seed germination) conducted using this platform. The experimental results showed that the platform can affect the processes, indicating that it provides a novel environment that has not been investigated before and that the effects of such an environment on many different physical, chemical, or biological processes can be potentially useful for applications in many fields.

  12. 76 FR 61750 - Vehicle-Mounted Elevating and Rotating Work Platforms (Aerial Lifts); Extension of the Office of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-05

    ...] Vehicle-Mounted Elevating and Rotating Work Platforms (Aerial Lifts); Extension of the Office of... requirement contained in the Standard on Vehicle-Mounted Elevating and Rotating Work Platforms (Aerial Lifts... by ensuring that aerial lifts are in safe operating condition. DATES: Comments must be submitted...

  13. Comparison of fixed-bearing and mobile-bearing total knee arthroplasty after high tibial osteotomy.

    PubMed

    Hernigou, Philippe; Huys, Maxime; Pariat, Jacques; Roubineau, François; Flouzat Lachaniette, Charles Henri; Dubory, Arnaud

    2018-02-01

    There is no information comparing the results of fixed-bearing total knee replacement and mobile-bearing total knee replacement in the same patients previously treated by high tibial osteotomy. The purpose was therefore to compare fixed-bearing and mobile-bearing total knee replacements in patients treated with previous high tibial osteotomy. We compared the results of 57 patients with osteoarthritis who had received a fixed-bearing prosthesis after high tibial osteotomy with the results of 41 matched patients who had received a rotating platform after high tibial osteotomy. The match was made for length of follow-up period. The mean follow-up was 17 years (range, 15-20 years). The patients were assessed clinically and radiographically. The pre-operative knee scores had no statistically significant differences between the two groups. So was the case with the intra-operative releases, blood loss, thromboembolic complications and infection rates in either group. There was significant improvement in both groups of knees, and no significant difference was observed between the groups (i.e., fixed-bearing and mobile-bearing knees) for the mean Knee Society knee clinical score (95 and 92 points, respectively), or the Knee Society knee functional score (82 and 83 points, respectively) at the latest follow-up. However, the mean post-operative knee motion was higher for the fixed-bearing group (117° versus 110°). In the fixed-bearing group, one knee was revised because of periprosthetic fracture. In the rotating platform mobile-bearing group, one knee was revised because of aseptic loosening of the tibial component. The Kaplan-Meier survivorship for revision at ten years of follow-up was 95.2% for the fixed bearing prosthesis and 91.1% for the rotating platform mobile-bearing prosthesis. Although we did manage to detect significant differences mainly in clinical and radiographic results between the two groups, we found no superiority or inferiority of the mobile-bearing total knee prosthesis over the fixed-bearing total knee prosthesis for patients previously operated by high tibial osteotomy.

  14. Turbine blade and non-integral platform with pin attachment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, Christian X; Eng, Darryl; Marra, John J

    Platforms (36, 38) span between turbine blades (23, 24, 25) on a disk (32). Each platform may be individually mounted to the disk by a pin attachment (42). Each platform (36) may have a rotationally rearward edge portion (50) that underlies a forward portion (45) of the adjacent platform (38). This limits centrifugal bending of the rearward portion of the platform, and provides coolant sealing. The rotationally forward edge (44A, 44B) of the platform overlies a seal element (51) on the pressure side (28) of the forwardly adjacent blade, and does not underlie a shelf on that blade. The pinmore » attachment allows radial mounting of each platform onto the disk via tilting (60) of the platform during mounting to provide mounting clearance for the rotationally rearward edge portion (50). This facilitates quick platform replacement without blade removal.« less

  15. Turbine blade and non-integral platform with pin attachment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, Christian Xavier; Eng, Darryl; Marra, John J.

    2016-08-02

    Platforms (36, 38) span between turbine blades (23, 24, 25) on a disk (32). Each platform may be individually mounted to the disk by a pin attachment (42). Each platform (36) may have a rotationally rearward edge portion (50) that underlies a forward portion (45) of the adjacent platform (38). This limits centrifugal bending of the rearward portion of the platform, and provides coolant sealing. The rotationally forward edge (44A, 44B) of the platform overlies a seal element (51) on the pressure side (28) of the forwardly adjacent blade, and does not underlie a shelf on that blade. The pinmore » attachment allows radial mounting of each platform onto the disk via tilting (60) of the platform during mounting to provide mounting clearance for the rotationally rearward edge portion (50). This facilitates quick platform replacement without blade removal.« less

  16. Helicopter Flight Simulation Motion Platform Requirements

    NASA Technical Reports Server (NTRS)

    Schroeder, Jeffery Allyn

    1999-01-01

    To determine motion fidelity requirements, a series of piloted simulations was performed. Several key results were found. First, lateral and vertical translational platform cues had significant effects on fidelity. Their presence improved performance and reduced pilot workload. Second, yaw and roll rotational platform cues were not as important as the translational platform cues. In particular, the yaw rotational motion platform cue did not appear at all useful in improving performance or reducing workload. Third, when the lateral translational platform cue was combined with visual yaw rotational cues, pilots believed the platform was rotating when it was not. Thus, simulator systems can be made more efficient by proper combination of platform and visual cues. Fourth, motion fidelity specifications were revised that now provide simulator users with a better prediction of motion fidelity based upon the frequency responses of their motion control laws. Fifth, vertical platform motion affected pilot estimates of steady-state altitude during altitude repositioning. Finally, the combined results led to a general method for configuring helicopter motion systems and for developing simulator tasks that more likely represent actual flight. The overall results can serve as a guide to future simulator designers and to today's operators.

  17. Single-ended counter-rotating radial turbine for space application

    DOEpatents

    Coomes, E.P.; Wilson, D.G.; Webb, B.J.; McCabe, S.J.

    1987-05-13

    A single-ended turbine with counter-rotating blades operating with sodium as the working fluid. The single-ended, counter-rotating feature of the turbine results in zero torque application to a space platform. Thus, maneuvering of the platform is not adversely affected by the turbine. 4 figs.

  18. A new family of omnidirectional and holonomic wheeled platforms for mobile robots

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pin, F.G.; Killough, S.M.

    1994-08-01

    This paper presents the concepts for a new family of holonomic wheeled platforms that feature full omnidirectionality with simultaneous and independently controlled rotational and translational motion capabilities. The authors first present the orthogonal-wheels'' concept and the two major wheel assemblies on which these platforms are based. The authors then describe how a combination of these assemblies with appropriate control can be used to generate an omnidirectional capability for mobile robot platforms. Several alternative designs are considered, and their respective characteristics with respect to rotational and translational motion control are discussed. The design and control of a prototype platform developed tomore » test and demonstrate the proposed concepts is then described, and experimental results illustrating the full omnidirectionality of the platforms with decoupled rotational and translational degrees of freedom are presented.« less

  19. Intraoperative evaluation of total knee replacement: kinematic assessment with a navigation system.

    PubMed

    Casino, Daniela; Zaffagnini, Stefano; Martelli, Sandra; Lopomo, Nicola; Bignozzi, Simone; Iacono, Francesco; Russo, Alessandro; Marcacci, Maurilio

    2009-04-01

    Interest in the kinematics of reconstructed knees has increased since it was shown that the alteration of knee motion could lead to abnormal wear and damage to soft tissues. We performed intraoperative kinematic measurements using a navigation system to study knee kinematics before and after posterior substituting rotating platform total knee arthroplasty (TKA). We verified intraoperatively (1) if varus/valgus (VV) laxity and anterior/posterior (AP) laxity were restored after TKA; (2) if TKA induced abnormal femoral rollback; and (3) how tibial axial rotation was influenced by TKA throughout the range of flexion. We found that TKA improved alignment in preoperative osteoarthritic varus knees which became neutral after surgery and maintained a neutral alignment in neutral knees. The VV stability at 0 degrees was restored while AP laxity at 90 degrees significantly increased after TKA. Following TKA, the femur had an abnormal anterior translation up to 60 degrees of flexion, followed by a small rollback of 12 +/- 5 mm. TKA influenced the tibia rotation pattern during flexion, but not the total amount of internal/external rotation throughout whole range of flexion, which was preserved after TKA (6 degrees +/- 5 degrees ). This study showed that the protocol proposed might be useful to adjust knee stability at time zero and that knee kinematic outcome during total knee replacement can be monitored by a navigation system.

  20. Multi-axis planar slide system

    DOEpatents

    Bieg, Lothar F.

    2002-01-01

    An apparatus for positioning an item that provides two-dimensional, independent orthogonal motion of a platform in a X-Y plane. A pair of master and slave disks engages opposite sides of the platform. Rotational drivers are connected to master disks so the disks rotate eccentrically about axes of rotation. Opposing slave disks are connected to master disks on opposite sides of the platform by a timing belt, or are electronically synchronized together using stepper motors, to effect coordinated motion. The coordinated eccentric motion of the pairs of master/slave disks compels smooth linear motion of the platform in the X-Y plane without backlash. The apparatus can be a planar mechanism implemented in a MEMS device.

  1. Compensation to whole body active rotation perturbation.

    PubMed

    Rossi, S; Gazzellini, S; Petrarca, M; Patanè, F; Salfa, I; Castelli, E; Cappa, P

    2014-01-01

    The aim of the present study is the exploration of the compensation mechanisms in healthy adults elicited by superimposing a horizontal perturbation, through a rotation of the support base, during a whole body active rotation around the participant's own vertical body axis. Eight healthy participants stood on a rotating platform while executing 90° whole body rotations under three conditions: no concurrent platform rotation (NP), support surface rotation of ± 45° in the same (45-S) and opposite (45-O) directions. Participants' kinematics and CoP displacements were analyzed with an optoelectronic system and a force platform. In both 45-S and 45-O conditions, there was a tendency for the head to be affected by the external perturbation and to be the last and least perturbed segment while the pelvis was the most perturbed. The observed reduced head perturbation in 45-S and 45-O trials is consistent with a goal-oriented strategy mediated by vision and vestibular information, whereas the tuning of lumbar rotation is consistent with control mechanisms mediated by somato-sensory information. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Design, Analysis, Hybrid Testing and Orientation Control of a Floating Platform with Counter-Rotating Vertical-Axis Wind Turbines

    NASA Astrophysics Data System (ADS)

    Kanner, Samuel Adam Chinman

    The design and operation of two counter-rotating vertical-axis wind turbines on a floating, semi-submersible platform is studied. The technology, called the Multiple Integrated and Synchronized Turbines (MIST) platform has the potential to reduce the cost of offshore wind energy per unit of installed capacity. Attached to the platform are closely-spaced, counter-rotating turbines, which can achieve a higher power density per planform area because of synergistic interaction effects. The purpose of the research is to control the orientation of the platform and rotational speeds of the turbines by modifying the energy absorbed by each of the generators of the turbines. To analyze the various aspects of the platform and wind turbines, the analysis is drawn from the fields of hydrodynamics, electromagnetics, aerodynamics and control theory. To study the hydrodynamics of the floating platform in incident monochromatic waves, potential theory is utilized, taking into account the slow-drift yaw motion of the platform. Steady, second-order moments that are spatially dependent (i.e., dependent on the platform's yaw orientation relative to the incident waves) are given special attention since there are no natural restoring yaw moment. The aerodynamics of the counter-rotating turbines are studied in collaboration with researchers at the UC Berkeley Mathematics Department using a high-order, implicit, large-eddy simulation. An element flipping technique is utilized to extend the method to a domain with counter-rotating turbines and the effects from the closely-spaced turbines is compared with existing experimental data. Hybrid testing techniques on a model platform are utilized to prove the controllability of the platform in lieu of a wind-wave tank. A 1:82 model-scale floating platform is fabricated and tested at the UC Berkeley Physical-Model Testing Facility. The vertical-axis wind turbines are simulated by spinning, controllable actuators that can be updated in real-time of the model scale. Under certain wind and wave headings, it is possible to control the orientation of the platform in regular waves to maximize the power output from the turbines. A time-domain numerical simulation tool is able to confirm some of the experimental findings, taking into account the decoupled properties of the slow-drift hydrodynamics and wind turbine aerodynamics. Future platform designs are discussed, including the French-based, pre-commercial design from Nenuphar Wind, called the TwinFloat, which is closely related to concepts examined in the thesis.

  3. Helicopter flight simulation motion platform requirements

    NASA Astrophysics Data System (ADS)

    Schroeder, Jeffery Allyn

    Flight simulators attempt to reproduce in-flight pilot-vehicle behavior on the ground. This reproduction is challenging for helicopter simulators, as the pilot is often inextricably dependent on external cues for pilot-vehicle stabilization. One important simulator cue is platform motion; however, its required fidelity is unknown. To determine the required motion fidelity, several unique experiments were performed. A large displacement motion platform was used that allowed pilots to fly tasks with matched motion and visual cues. Then, the platform motion was modified to give cues varying from full motion to no motion. Several key results were found. First, lateral and vertical translational platform cues had significant effects on fidelity. Their presence improved performance and reduced pilot workload. Second, yaw and roll rotational platform cues were not as important as the translational platform cues. In particular, the yaw rotational motion platform cue did not appear at all useful in improving performance or reducing workload. Third, when the lateral translational platform cue was combined with visual yaw rotational cues, pilots believed the platform was rotating when it was not. Thus, simulator systems can be made more efficient by proper combination of platform and visual cues. Fourth, motion fidelity specifications were revised that now provide simulator users with a better prediction of motion fidelity based upon the frequency responses of their motion control laws. Fifth, vertical platform motion affected pilot estimates of steady-state altitude during altitude repositionings. This refutes the view that pilots estimate altitude and altitude rate in simulation solely from visual cues. Finally, the combined results led to a general method for configuring helicopter motion systems and for developing simulator tasks that more likely represent actual flight. The overall results can serve as a guide to future simulator designers and to today's operators.

  4. Rotating Desk for Collaboration by Two Computer Programmers

    NASA Technical Reports Server (NTRS)

    Riley, John Thomas

    2005-01-01

    A special-purpose desk has been designed to facilitate collaboration by two computer programmers sharing one desktop computer or computer terminal. The impetus for the design is a trend toward what is known in the software industry as extreme programming an approach intended to ensure high quality without sacrificing the quantity of computer code produced. Programmers working in pairs is a major feature of extreme programming. The present desk design minimizes the stress of the collaborative work environment. It supports both quality and work flow by making it unnecessary for programmers to get in each other s way. The desk (see figure) includes a rotating platform that supports a computer video monitor, keyboard, and mouse. The desk enables one programmer to work on the keyboard for any amount of time and then the other programmer to take over without breaking the train of thought. The rotating platform is supported by a turntable bearing that, in turn, is supported by a weighted base. The platform contains weights to improve its balance. The base includes a stand for a computer, and is shaped and dimensioned to provide adequate foot clearance for both users. The platform includes an adjustable stand for the monitor, a surface for the keyboard and mouse, and spaces for work papers, drinks, and snacks. The heights of the monitor, keyboard, and mouse are set to minimize stress. The platform can be rotated through an angle of 40 to give either user a straight-on view of the monitor and full access to the keyboard and mouse. Magnetic latches keep the platform preferentially at either of the two extremes of rotation. To switch between users, one simply grabs the edge of the platform and pulls it around. The magnetic latch is easily released, allowing the platform to rotate freely to the position of the other user

  5. No Differences Identified in Transverse Plane Biomechanics Between Medial Pivot and Rotating Platform Total Knee Implant Designs.

    PubMed

    Papagiannis, Georgios I; Roumpelakis, Ilias M; Triantafyllou, Athanasios I; Makris, Ioannis N; Babis, George C

    2016-08-01

    Total knee arthroplasties (TKAs) using well-designed, fixed bearing prostheses, such as medial pivot (MP), have produced good long-term results. Rotating-platform, posterior-stabilized (RP-PS) mobile bearing implants were designed to decrease polyethylene wear. Sagittal and coronal plane TKA biomechanics are well examined and correlated to polyethylene wear. However, limited research findings describe this relationship in transverse plane. We assumed that although axial plane biomechanics might not be the most destructive parameters on polyethylene wear, it is important to clarify their role because both joint kinematics and kinetics in all 3 planes are important input parameters for TKA wear testing (International Organization for Standardization 14243-1 and 14343-3). Our hypothesis was that transverse plane overall range of motion (ROM) and/or peak moment show differences that reflect on wear advantages when compared RP-PS implants to MP designs. Two groups (MPs = 24 and RP-PSs = 22 subjects) were examined by using 3D gait analysis. The variables were total internal-external rotation (IER) ROM and peak IER moments. No statistically significant difference was demonstrated between the 2 groups in kinetics (P = .389) or kinematics (P = .275). In the present study, no wear advantages were found between 2 TKAs. Both designs showed identical kinetics at the transverse plane in level-ground walking. Kinematic analysis could not illustrate any statistically significant difference in terms of overall IER ROM. Nevertheless, kinematic gait pattern differences observed possibly reflect different patterns of joint surface motion or abnormal gait patterns. Thus, wear testing with various input waveforms combined with functional data analysis will be necessary to identify the actual effects of gait variability on polyethylene wear. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Three Accessories for a Rotating Platform.

    ERIC Educational Resources Information Center

    Riley, James A.; Fryer, Oscar G.

    1980-01-01

    Describes three accessories developed to be used in conjunction with the rotating platform or turntable. Three demonstrations using these accessories are included. These demonstrations are: (a) conservation of angular momentum; (b) gravity-defying goblets; and (c) direct measurement of centripetal force. (HM)

  7. Bi-directional planar slide mechanism

    DOEpatents

    Bieg, Lothar F.

    2003-11-04

    A bi-directional slide mechanism. A pair of master and slave disks engages opposite sides of the platform. Rotational drivers are connected to master disks so the disks rotate eccentrically about their respective axes of rotation. Opposing slave disks are connected to master disks on opposite sides of the platform by a circuitous mechanical linkage, or are electronically synchronized together using stepper motors, to effect coordinated motion. The synchronized eccentric motion of the pairs of master/slave disks compels smooth linear motion of the platform forwards and backwards without backlash. The apparatus can be incorporated in a MEMS device.

  8. Two-step tomographic reconstructions of temperature and species concentration in a flame based on laser absorption measurements with a rotation platform

    NASA Astrophysics Data System (ADS)

    Xia, Huihui; Kan, Ruifeng; Xu, Zhenyu; He, Yabai; Liu, Jianguo; Chen, Bing; Yang, Chenguang; Yao, Lu; Wei, Min; Zhang, Guangle

    2017-03-01

    We present a system for accurate tomographic reconstruction of the combustion temperature and H2O vapor concentration of a flame based on laser absorption measurements, in combination with an innovative two-step algebraic reconstruction technique. A total of 11 collimated laser beams generated from outputs of fiber-coupled diode lasers formed a two-dimensional 5 × 6 orthogonal beam grids and measured at two H2O absorption transitions (7154.354/7154.353 cm-1 and 7467.769 cm-1). The measurement system was designed on a rotation platform to achieve a two-folder improvement in spatial resolution. Numerical simulation showed that the proposed two-step algebraic reconstruction technique for temperature and concentration, respectively, greatly improved the reconstruction accuracy of species concentration when compared with a traditional calculation. Experimental results demonstrated the good performances of the measurement system and the two-step reconstruction technique for applications such as flame monitoring and combustion diagnosis.

  9. Comprehensive Study of the Flow Control Strategy in a Wirelessly Charged Centrifugal Microfluidic Platform with Two Rotation Axes.

    PubMed

    Zhu, Yunzeng; Chen, Yiqi; Meng, Xiangrui; Wang, Jing; Lu, Ying; Xu, Youchun; Cheng, Jing

    2017-09-05

    Centrifugal microfluidics has been widely applied in the sample-in-answer-out systems for the analyses of nucleic acids, proteins, and small molecules. However, the inherent characteristic of unidirectional fluid propulsion limits the flexibility of these fluidic chips. Providing an extra degree of freedom to allow the unconstrained and reversible pumping of liquid is an effective strategy to address this limitation. In this study, a wirelessly charged centrifugal microfluidic platform with two rotation axes has been constructed and the flow control strategy in such platform with two degrees of freedom was comprehensively studied for the first time. Inductively coupled coils are installed on the platform to achieve wireless power transfer to the spinning stage. A micro servo motor is mounted on both sides of the stage to alter the orientation of the device around a secondary rotation axis on demand during stage rotation. The basic liquid operations on this platform, including directional transport of liquid, valving, metering, and mixing, are comprehensively studied and realized. Finally, a chip for the simultaneous determination of hexavalent chromium [Cr(VI)] and methanal in water samples is designed and tested based on the strategy presented in this paper, demonstrating the potential use of this platform for on-site environmental monitoring, food safety testing, and other life science applications.

  10. Apparatus to position a microelectromechanical platform

    DOEpatents

    Miller, Samuel Lee; Rodgers, Murray Steven

    2003-09-23

    The present invention comprises a microelectromechanical positioner to achieve substantially translational positioning of a platform without rotational motion, thereby maintaining a constant angular orientation of the platform during movement. A linkage mechanism of the positioner can comprise parallelogram linkages to constrain the rotational motion of the platform. Such linkages further can comprise flexural hinges or other turning joints at the linkage pivots to eliminate the need for rubbing surfaces. A plurality of the linkage mechanisms can be used to enable translational motion of the platform with two degrees of freedom. A variety of means can be used to actuate the positioner. Independent actuation of the anchor links of the linkage mechanisms with rotary electrostatic actuators can be used to provide controlled translational movement of the platform.

  11. Linear prediction data extrapolation superresolution radar imaging

    NASA Astrophysics Data System (ADS)

    Zhu, Zhaoda; Ye, Zhenru; Wu, Xiaoqing

    1993-05-01

    Range resolution and cross-range resolution of range-doppler imaging radars are related to the effective bandwidth of transmitted signal and the angle through which the object rotates relatively to the radar line of sight (RLOS) during the coherent processing time, respectively. In this paper, linear prediction data extrapolation discrete Fourier transform (LPDEDFT) superresolution imaging method is investigated for the purpose of surpassing the limitation imposed by the conventional FFT range-doppler processing and improving the resolution capability of range-doppler imaging radar. The LPDEDFT superresolution imaging method, which is conceptually simple, consists of extrapolating observed data beyond the observation windows by means of linear prediction, and then performing the conventional IDFT of the extrapolated data. The live data of a metalized scale model B-52 aircraft mounted on a rotating platform in a microwave anechoic chamber and a flying Boeing-727 aircraft were processed. It is concluded that, compared to the conventional Fourier method, either higher resolution for the same effective bandwidth of transmitted signals and total rotation angle of the object or equal-quality images from smaller bandwidth and total angle may be obtained by LPDEDFT.

  12. Knee stability before and after total and unicondylar knee replacement: in vivo kinematic evaluation utilizing navigation.

    PubMed

    Casino, Daniela; Martelli, Sandra; Zaffagnini, Stefano; Lopomo, Nicola; Iacono, Francesco; Bignozzi, Simone; Visani, Andrea; Marcacci, Maurilio

    2009-02-01

    Surgical navigation systems are currently used to guide the surgeon in the correct alignment of the implant. The aim of this study was to expand the use of navigation systems by proposing a surgical protocol for intraoperative kinematics evaluations during knee arthroplasty. The protocol was evaluated on 20 patients, half undergoing unicondylar knee arthroplasty (UKA) and half undergoing posterior-substituting, rotating-platform total knee arthroplasty (TKA). The protocol includes a simple acquisition procedure and an original elaboration methodology. Kinematic tests were performed before and after surgery and included varus/valgus stress at 0 and 30 degrees and passive range of motion. Both UKA and TKA improved varus/valgus stability in extension and preserved the total magnitude of screw-home motion during flexion. Moreover, compared to preoperative conditions, values assumed by tibial axial rotation during flexion in TKA knees were more similar to the rotating patterns of UKA knees. The analysis of the anteroposterior displacement of the knee compartments confirmed that the two prostheses did not produce medial pivoting, but achieved a postoperative normal behavior. These results demonstrated that proposed intraoperative kinematics evaluations by a navigation system provided new information on the functional outcome of the reconstruction useful to restore knee kinematics during surgery.

  13. Automated centrifugal-microfluidic platform for DNA purification using laser burst valve and coriolis effect.

    PubMed

    Choi, Min-Seong; Yoo, Jae-Chern

    2015-04-01

    We report a fully automated DNA purification platform with a micropored membrane in the channel utilizing centrifugal microfluidics on a lab-on-a-disc (LOD). The microfluidic flow in the LOD, into which the reagents are injected for DNA purification, is controlled by a single motor and laser burst valve. The sample and reagents pass successively through the micropored membrane in the channel when each laser burst valve is opened. The Coriolis effect is used by rotating the LOD bi-directionally to increase the purity of the DNA, thereby preventing the mixing of the waste and elution solutions. The total process from the lysed sample injection into the LOD to obtaining the purified DNA was finished within 7 min with only one manual step. The experimental result for Salmonella shows that the proposed microfluidic platform is comparable to the existing devices in terms of the purity and yield of DNA.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abercrombie, Robert Knox; Richardson, Gregory David; Scudiere, Matthew Bligh

    A pad is disclosed for use in a weighing system for weighing a load. The pad includes a weighing platform, load cells, and foot members. Improvements to the pad reduce or substantially eliminate rotation of one or more of the corner foot members. A flexible foot strap disposed between the corner foot members reduces rotation of the respective foot members about vertical axes through the corner foot members and couples the corner foot members such that rotation of one corner foot member results in substantially the same amount of rotation of the other corner foot member. In a strapless variantmore » one or more fasteners prevents substantially all rotation of a foot member. In a diagonal variant, a foot strap extends between a corner foot member and the weighing platform to reduce rotation of the foot member about a vertical axis through the corner foot member.« less

  15. Measuring Lift with the Wright Airfoils

    ERIC Educational Resources Information Center

    Heavers, Richard M.; Soleymanloo, Arianne

    2011-01-01

    In this laboratory or demonstration exercise, we mount a small airfoil with its long axis vertical at one end of a nearly frictionless rotating platform. Air from a leaf blower produces a sidewise lift force L on the airfoil and a drag force D in the direction of the air flow (Fig. 1). The rotating platform is kept in equilibrium by adding weights…

  16. Visible and infrared polarization ratio spectroreflectometer

    NASA Technical Reports Server (NTRS)

    Batten, C. E. (Inventor)

    1980-01-01

    The instrument assists in determining the refractive index and absorption index, at different spectral frequencies, of a solid sample by illuminating the sample at various angles in incidence and measuring the corresponding reflected intensities at various spectral frequencies and polarization angles. The ratio of the intensity of the reflected light for parallel polarized light to that for perpendicular polarized light at two different angles of incidence can be used to determine the optical constants of the sample. The invention involves an apparatus for facilitating the utilization of a wide variety of angles of incidence. The light source and polarizing element are positioned on an outer platform; the sample is positioned on an inner platform. The two platforms rotate about a common axis and cooperate in their rotation such that the sample is rotated one degree for every two degrees of rotation of the light source. This maintains the impingement of the reflected light upon the detector for any angle of incidence without moving or adjusting the detector which allows a continuous change in the angle of incidence.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qian, X; Wuu, C; Admovics, J

    Purpose: A 3-D radiochromic plastic dosimeter has been used to cross-test the isocentricity of a high resolution image-guided small animal microirradiation platform. In this platform, the mouse stage rotating for cone beam CT imaging is perpendicular to the gantry rotation for sub-millimeter radiation delivery. A 3-D dosimeter can be used to verify both imaging and irradiation coordinates. Methods: A 3-D dosimeter and optical CT scanner were used in this study. In the platform, both mouse stage and gantry can rotate 360° with rotation axis perpendicular to each other. Isocentricity and coincidence of mouse stage and gantry rotations were evaluated usingmore » star patterns. A 3-D dosimeter was placed on mouse stage with center at platform isocenter approximately. For CBCT isocentricity, with gantry moved to 90°, the mouse stage rotated horizontally while the x-ray was delivered to the dosimeter at certain angles. For irradiation isocentricity, the gantry rotated 360° to deliver beams to the dosimeter at certain angles for star patterns. The uncertainties and agreement of both CBCT and irradiation isocenters can be determined from the star patterns. Both procedures were repeated 3 times using 3 dosimeters to determine short-term reproducibility. Finally, dosimeters were scanned using optical CT scanner to obtain the results. Results: The gantry isocentricity is 0.9 ± 0.1 mm and mouse stage rotation isocentricity is about 0.91 ± 0.11 mm. Agreement between the measured isocenters of irradiation and imaging coordinates was determined. The short-term reproducibility test yielded 0.5 ± 0.1 mm between the imaging isocenter and the irradiation isocenter, with a maximum displacement of 0.7 ± 0.1 mm. Conclusion: The 3-D dosimeter can be very useful in precise verification of targeting for a small animal irradiation research. In addition, a single 3-D dosimeter can provide information in both geometric and dosimetric uncertainty, which is crucial for translational studies.« less

  18. Latex Micro-balloon Pumping in Centrifugal Microfluidic Platforms

    PubMed Central

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Al-Faqheri, Wisam; Thio, Tzer Hwai Gilbert; Kazemzadeh, Amin; Wadi harun, Sulaiman; Madou, Marc

    2014-01-01

    Centrifugal microfluidic platforms have emerged as point-of-care diagnostic tools. However, the unidirectional nature of the centrifugal force limits the available space for multi-stepped processes on a single microfluidics disc. To overcome this limitation, a passive pneumatic pumping method actuated at high rotational speeds has been previously proposed to pump liquid against the centrifugal force. In this paper, a novel micro-balloon pumping method that relies on elastic energy stored in a latex membrane is introduced. It operates at low rotational speeds and pumps a larger volume of liquid towards the centre of the disc. Two different micro-balloon pumping designs have been developed to study the pump performance and capacity at a range of rotational frequencies from 0 to 1500 rpm. The behaviour of the micro-balloon pump on the centrifugal microfluidic platforms has been theoretically analysed and compared with the experimental data. The experimental data shows that, the developed pumping method dramatically decreases the required rotational speed to pump liquid compared to the previously developed pneumatic pumping methods. It also shows that within a range of rotational speed, desirable volume of liquid can be stored and pumped by adjusting the size of the micro-balloon. PMID:24441792

  19. Power turbine ventilation system

    NASA Technical Reports Server (NTRS)

    Wakeman, Thomas G. (Inventor); Brown, Richard W. (Inventor)

    1991-01-01

    Air control mechanism within a power turbine section of a gas turbine engine. The power turbine section includes a rotor and at least one variable pitch propulsor blade. The propulsor blade is coupled to and extends radially outwardly of the rotor. A first annular fairing is rotatable with the propulsor blade and interposed between the propulsor blade and the rotor. A second fairing is located longitudinally adjacent to the first fairing. The first fairing and the second fairing are differentially rotatable. The air control mechanism includes a platform fixedly coupled to a radially inner end of the propulsor blade. The platform is generally positioned in a first opening and a first fairing. The platform and the first fairing define an outer space. In a first position corresponding with a first propulsor blade pitch, the platform is substantially conformal with the first fairing. In a second position corresponding with the second propulsor blade pitch, an edge portion of the platform is displaced radially outwardly from the first fairing. When the blades are in the second position and rotating about the engine axis, the displacement of the edge portion with respect to the first fairing allows air to flow from the outer space to the annular cavity.

  20. Performance assessment of a programmable five degrees-of-freedom motion platform for quality assurance of motion management techniques in radiotherapy.

    PubMed

    Huang, Chen-Yu; Keall, Paul; Rice, Adam; Colvill, Emma; Ng, Jin Aun; Booth, Jeremy T

    2017-09-01

    Inter-fraction and intra-fraction motion management methods are increasingly applied clinically and require the development of advanced motion platforms to facilitate testing and quality assurance program development. The aim of this study was to assess the performance of a 5 degrees-of-freedom (DoF) programmable motion platform HexaMotion (ScandiDos, Uppsala, Sweden) towards clinically observed tumor motion range, velocity, acceleration and the accuracy requirements of SABR prescribed in AAPM Task Group 142. Performance specifications for the motion platform were derived from literature regarding the motion characteristics of prostate and lung tumor targets required for real time motion management. The performance of the programmable motion platform was evaluated against (1) maximum range, velocity and acceleration (5 DoF), (2) static position accuracy (5 DoF) and (3) dynamic position accuracy using patient-derived prostate and lung tumor motion traces (3 DoF). Translational motion accuracy was compared against electromagnetic transponder measurements. Rotation was benchmarked with a digital inclinometer. The static accuracy and reproducibility for translation and rotation was <0.1 mm or <0.1°, respectively. The accuracy of reproducing dynamic patient motion was <0.3 mm. The motion platform's range met the need to reproduce clinically relevant translation and rotation ranges and its accuracy met the TG 142 requirements for SABR. The range, velocity and acceleration of the motion platform are sufficient to reproduce lung and prostate tumor motion for motion management. Programmable motion platforms are valuable tools in the investigation, quality assurance and commissioning of motion management systems in radiation oncology.

  1. Effects of the humeral tray component positioning for onlay reverse shoulder arthroplasty design: a biomechanical analysis.

    PubMed

    Berhouet, Julien; Kontaxis, Andreas; Gulotta, Lawrence V; Craig, Edward; Warren, Russel; Dines, Joshua; Dines, David

    2015-04-01

    Recent shoulder prostheses have introduced a concept of a universal humeral stem component platform that has an onlay humeral tray for the reverse total shoulder arthroplasty (RTSA). No studies have reported how humeral tray positioning can affect the biomechanics of RTSA. The Newcastle Shoulder Model was used to investigate the biomechanical effect of humeral tray positioning in the Biomet Comprehensive Total Shoulder System (Biomet, Warsaw, IN, USA) RTSA. Five humeral tray configuration positions were tested: no offset, and 5 mm offset in the anterior, posterior, medial, and lateral positions. Superior and inferior impingement were evaluated for abduction, scapular plane elevation, forward flexion, and external/internal rotation with the elbow at the side (adduction) and at 90° of shoulder abduction. Muscle lengths and moment arms (elevating and rotational) were calculated for the deltoid, the infraspinatus, the teres minor, and the subscapularis. Inferior impingement was not affected by the humeral tray position. There was less superior impingement during abduction, scapular plane elevation, and rotation with the shoulder when the tray was placed laterally or posteriorly. The subscapularis rotational moment arm was increased with a posterior offset, whereas infraspinatus and teres minor rotational moment arms were increased with an anterior offset. Very little change was observed for the deltoid elevating moment arm or for its muscle length. Positioning the humeral tray with posterior offset offers a biomechanical advantage for patients needing RTSA by decreasing superior impingement and increasing the internal rotational moment arm of the subscapularis, without creating inferior impingement. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  2. Posterior Shift of Contact Point between Femoral Component and Polyethylene in the LCS Rotating Platform Implant under Weight Bearing Condition.

    PubMed

    Oh, Won Seok; Lee, Yong Seuk; Kim, Byung Kak; Sim, Jae Ang; Lee, Beom Koo

    2016-06-01

    To analyze the contact mechanics of the femoral component and polyethylene of the Low Contact Stress rotating platform (LCS-RP) in nonweight bearing and weight bearing conditions using full flexion lateral radiographs. From May 2009 to December 2013, 58 knees in 41 patients diagnosed with osteoarthritis and treated with total knee arthroplasty (TKA) were included in this study. TKA was performed using an LCS-RP knee prosthesis. Full flexion lateral radiographs in both weight bearing and nonweight bearing condition were taken at least one month postoperatively (average, 28.8 months). Translation of femoral component was determined by the contact point between the femoral component and polyethylene. Maximum flexion was measured as the angle between the lines drawn at the midpoint of the femur and tibia. Posterior shift of the contact point in LCS-RP TKA was observed under weight bearing condition, which resulted in deeper flexion compared to LCS-RP TKA under nonweight bearing condition. In the LCS-RP TKA, the contact point between the femoral component and polyethylene moved posteriorly under weight bearing condition, and the joint was more congruent and maximum flexion increased with weight bearing.

  3. Linear thermal circulator based on Coriolis forces.

    PubMed

    Li, Huanan; Kottos, Tsampikos

    2015-02-01

    We show that the presence of a Coriolis force in a rotating linear lattice imposes a nonreciprocal propagation of the phononic heat carriers. Using this effect we propose the concept of Coriolis linear thermal circulator which can control the circulation of a heat current. A simple model of three coupled harmonic masses on a rotating platform permits us to demonstrate giant circulating rectification effects for moderate values of the angular velocities of the platform.

  4. Experiment research on inertia-aided adaptive electronic image stabilization of optical stable platform

    NASA Astrophysics Data System (ADS)

    Lu, Xiaodong; Wu, Tianze; Zhou, Jun; Zhao, Bin; Ma, Xiaoyuan; Tang, Xiucheng

    2016-03-01

    An electronic image stabilization method compounded with inertia information, which can compensate the coupling interference caused by the pitch-yaw movement of the optical stable platform system, has been proposed in this paper. Firstly the mechanisms of coning rotation and lever-arm translation of line of sight (LOS) are analyzed during the stabilization process under moving carriers, and the mathematical model which describes the relationship between LOS rotation angle and platform attitude angle are derived. Then the image spin angle caused by coning rotation is estimated by using inertia information. Furthermore, an adaptive block matching method, which based on image edge and angular point, is proposed to smooth the jitter created by the lever-arm translation. This method optimizes the matching process and strategies. Finally, the results of hardware-in-the-loop simulation verified the effectiveness and real-time performance of the proposed method.

  5. Mobile-bearing knees reduce rotational asymmetric wear.

    PubMed

    Ho, Fang-Yuan; Ma, Hon-Ming; Liau, Jiann-Jong; Yeh, Chuan-Ren; Huang, Chun-Hsiung

    2007-09-01

    Polyethylene wear of bearing components is the most common long-term complication in total knee arthroplasty. One would anticipate differing kinematics would generate different wear patterns (including wear type, degree, and symmetry) on the articulating surface of mobile-bearing and fixed-bearing inserts. Because mobile-bearing designs facilitate movement of the insert relative to the tray when the knee rotates, we hypothesized mobile-bearing designs would reduce the incidence of rotational asymmetric wear. We examined 51 worn tibial inserts, including 15 from mobile-bearing rotating-platform posterior-cruciate-sacrificing dished prostheses and 36 from fixed-bearing posterior-cruciate-retaining flat prostheses, which were retrieved at revision surgery with an average implantation time of 115 months. We divided wear types into low-grade wear (burnishing, abrasion, and cold flow) and high-grade wear (scratching, pitting, metal embedding, and delamination) to assess wear degree of polyethylene. To assess symmetry of wear, the insert surface was divided into medial and lateral sides and each side was further divided into three equal zones along the anteroposterior direction. Low-grade wear was more common in mobile-bearing knees, whereas high-grade wear was more common in fixed-bearing knees. We identified no internal/external rotational asymmetric wear or anteroposterior asymmetric wear in mobile-bearing knees.

  6. Omni-directional and holonomic rolling platform with decoupled rotational and translational degrees of freedom

    DOEpatents

    Pin, F.G.; Killough, S.M.

    1994-12-20

    A wheel assembly includes a support, a cage rotatably mounted on the support and having a longitudinal rotation axis, a first ball wheel rotatably mounted in the cage and having a rotation axis orthogonal to the rotation axis of the cage, and a second ball wheel rotatably mounted in the cage and having a rotation axis orthogonal to the rotation axis or the cage and to the rotation axis of the first ball wheel. A control circuit includes a photodetector signal which indicates ground contact for each ball wheel, and a tachometer which indicates actual drive shaft velocity. 6 figures.

  7. Omni-directional and holonomic rolling platform with decoupled rotational and translational degrees of freedom

    DOEpatents

    Pin, Francois G.; Killough, Stephen M.

    1994-01-01

    A wheel assembly includes a support, a cage rotatably mounted on the support and having a longitudinal rotation axis, a first ball wheel rotatably mounted in the cage and having a rotation axis orthogonal to the rotation axis of the cage, and a second ball wheel rotatably mounted in the cage and having a rotation axis orthogonal to the rotation axis or the cage and to the rotation axis of the first ball wheel. A control circuit includes a photodetector signal which indicates ground contact for each ball wheel, and a tachometer which indicates actual drive shaft velocity.

  8. A compensation method of lever arm effect for tri-axis hybrid inertial navigation system based on fiber optic gyro

    NASA Astrophysics Data System (ADS)

    Liu, Zengjun; Wang, Lei; Li, Kui; Gao, Jiaxin

    2017-05-01

    Hybrid inertial navigation system (HINS) is a new kind of inertial navigation system (INS), which combines advantages of platform INS, strap-down INS and rotational INS. HINS has a physical platform to isolate the angular motion as platform INS does, HINS also uses strap-down attitude algorithms and applies rotation modulation technique. Tri-axis HINS has three gimbals to isolate the angular motion in the dynamic base, in which way the system can reduce the effects of angular motion and improve the positioning precision. However, the angular motion will affect the compensation of some error parameters, especially for the lever arm effect. The lever arm effect caused by position errors between the accelerometers and rotation center cannot be ignored due to the rapid rotation of inertial measurement unit (IMU) and it will cause fluctuation and stage in velocity in HINS. The influences of angular motion on the lever arm effect compensation are analyzed firstly in this paper, and then the compensation method of lever arm effect based on the photoelectric encoders in dynamic base is proposed. Results of experiments on turntable show that after compensation, the fluctuations and stages in velocity curve disappear.

  9. Conversion to Reverse Total Shoulder Arthroplasty with and without Humeral Stem Retention: The Role of a Convertible-Platform Stem.

    PubMed

    Crosby, Lynn A; Wright, Thomas W; Yu, Stephen; Zuckerman, Joseph D

    2017-05-03

    Revision shoulder arthroplasty is a technically challenging procedure. It is associated with increased blood loss and operative time, and it frequently necessitates revision implants, augments, and bone-grafting. Shoulder arthroplasty systems with a convertible-platform humeral stem have been developed to reduce the complexity of revision procedures by eliminating the need for humeral component explantation when converting from anatomic shoulder arthroplasty (hemiarthroplasty or total shoulder arthroplasty) to reverse total shoulder arthroplasty (rTSA). A multicenter, retrospective analysis involving 102 consecutive shoulders (102 patients) that underwent revision of an anatomic shoulder arthroplasty to an rTSA was conducted. During the revision, 73 of the shoulders needed exchange of the humeral stem (the exchange group) and 29 had retention of a convertible-platform humeral component (the retention group). Patient demographics, operative time, blood management, range of motion, complications, and patient-reported outcomes were compared between the 2 groups. Patients with retention had significantly shorter operative time (mean and standard deviation, 130 ± 48 versus 195 ± 58 minutes; p < 0.001) and lower estimated blood loss (292 ± 118 versus 492 ± 334 mL; p = 0.034). The rate of intraoperative complications was lower in the retention group (0% versus 15%; p = 0.027). Patients with retention had slightly better postoperative range of motion (active external rotation, 26° ± 23° versus 11° ± 23° [p = 0.006]; active forward elevation, 112° ± 37° versus 96° ± 33° [p = 0.055]). Shoulder arthroplasty systems that utilize a convertible-platform humeral stem offer an advantage for rTSA conversion in that a well-fixed, well-positioned humeral stem can be retained. There were significantly fewer complications as well as significantly decreased blood loss and operative time when a convertible-platform stem was utilized (p < 0.050). Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  10. Stepping in Place While Voluntarily Turning Around Produces a Long-Lasting Posteffect Consisting in Inadvertent Turning While Stepping Eyes Closed

    PubMed Central

    2016-01-01

    Training subjects to step in place on a rotating platform while maintaining a fixed body orientation in space produces a posteffect consisting in inadvertent turning around while stepping in place eyes closed (podokinetic after-rotation, PKAR). We tested the hypothesis that voluntary turning around while stepping in place also produces a posteffect similar to PKAR. Sixteen subjects performed 12 min of voluntary turning while stepping around their vertical axis eyes closed and 12 min of stepping in place eyes open on the center of a platform rotating at 60°/s (pretests). Then, subjects continued stepping in place eyes closed for at least 10 min (posteffect). We recorded the positions of markers fixed to head, shoulder, and feet. The posteffect of voluntary turning shared all features of PKAR. Time decay of angular velocity, stepping cadence, head acceleration, and ratio of angular velocity after to angular velocity before were similar between both protocols. Both postrotations took place inadvertently. The posteffects are possibly dependent on the repeated voluntary contraction of leg and foot intrarotating pelvic muscles that rotate the trunk over the stance foot, a synergy common to both protocols. We propose that stepping in place and voluntary turning can be a scheme ancillary to the rotating platform for training body segment coordination in patients with impairment of turning synergies of various origin. PMID:27635264

  11. Experimental research on a vibration isolation platform for momentum wheel assembly

    NASA Astrophysics Data System (ADS)

    Zhou, Weiyong; Li, Dongxu

    2013-03-01

    This paper focuses on experimental research on a vibration isolation platform for momentum wheel assembly (MWA). A vibration isolation platform, consisting of four folded beams, was designed to isolate the microvibrations produced by MWA during operation. The performance of the platform was investigated with an impact test to verify the natural frequencies and damping coefficients of the system when the MWA was at rest, and with a measurement system consisting of a Kistler table and an optical tabletop to monitor the microvibrations produced when the MWA operated at stable speed. The results show that although the sixth natural frequency of the system is 26.29 Hz (1577 rev/min) when the MWA is at rest, the critical speed occurs at 2600 rev/min due to the gyroscopic effect of the flywheel, and that the platform can effectively isolate the high frequency disturbances in the 100-300 Hz range in all six degrees of freedom. Thus, the gyroscopic effect force deserves more attention in the design and analysis of vibration isolation platform for rotating wheel assembly, and the platform in this paper is particularly effective for MWA, which generally operates at high rotating speed range.

  12. Of drops and bubbles - The technology of space processing

    NASA Technical Reports Server (NTRS)

    Subramanian, R. Shankar

    1984-01-01

    It is possible to manipulate a large, molten mass of material, such as a glass, aboard an orbital platform using acoustic fields. Attention is presently given to the problem of bubble removal from such a melt; it is desirable to make small bubbles coalesce into larger ones through floating melt rotation, to create an artificial convective field in which the bubbles will move centripetally to the axis of rotation. Computer models of bubble migration have been developed in order to define the operational conditions required aboard such experiment platforms as the Space Shuttle Orbiter.

  13. Using Kokkos for Performant Cross-Platform Acceleration of Liquid Rocket Simulations

    DTIC Science & Technology

    2017-05-08

    NUMBER (Include area code) 08 May 2017 Briefing Charts 05 April 2017 - 08 May 2017 Using Kokkos for Performant Cross-Platform Acceleration of Liquid ...ERC Incorporated RQRC AFRL-West Using Kokkos for Performant Cross-Platform Acceleration of Liquid Rocket Simulations 2DISTRIBUTION A: Approved for... Liquid Rocket Combustion Simulation SPACE simulation of rotating detonation engine (courtesy of Dr. Christopher Lietz) 3DISTRIBUTION A: Approved

  14. Note: computer controlled rotation mount for large diameter optics.

    PubMed

    Rakonjac, Ana; Roberts, Kris O; Deb, Amita B; Kjærgaard, Niels

    2013-02-01

    We describe the construction of a motorized optical rotation mount with a 40 mm clear aperture. The device is used to remotely control the power of large diameter laser beams for a magneto-optical trap. A piezo-electric ultrasonic motor on a printed circuit board provides rotation with a precision better than 0.03° and allows for a very compact design. The rotation unit is controlled from a computer via serial communication, making integration into most software control platforms straightforward.

  15. 29 CFR 1910.67 - Vehicle-mounted elevating and rotating work platforms.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....67 Section 1910.67 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR OCCUPATIONAL SAFETY AND HEALTH STANDARDS Powered Platforms, Manlifts, and...) Bursting safety factor. All critical hydraulic and pneumatic components shall comply with the provisions of...

  16. Motorized manipulator for positioning a TEM specimen

    DOEpatents

    Schmid, Andreas Karl; Andresen, Nord

    2010-12-14

    The invention relates to a motorized manipulator for positioning a TEM specimen holder with sub-micron resolution parallel to a y-z plane and rotating the specimen holder in the y-z plane, the manipulator comprising a base (2), and attachment means (30) for attaching the specimen holder to the manipulator, characterized in that the manipulator further comprises at least three nano-actuators (3.sup.a, 3.sup.b, 3.sup.c) mounted on the base, each nano-actuator showing a tip (4.sup.a, 4.sup.b, 4.sup.c), the at least three tips defining the y-z plane, each tip capable of moving with respect to the base in the y-z plane; a platform (5) in contact with the tips of the nano-actuators; and clamping means (6) for pressing the platform against the tips of the nano-actuators; as a result of which the nano-actuators can rotate the platform with respect to the base in the y-z plane and translate the platform parallel to the y-z plane.

  17. AC electric field induced dipole-based on-chip 3D cell rotation.

    PubMed

    Benhal, Prateek; Chase, J Geoffrey; Gaynor, Paul; Oback, Björn; Wang, Wenhui

    2014-08-07

    The precise rotation of suspended cells is one of the many fundamental manipulations used in a wide range of biotechnological applications such as cell injection and enucleation in nuclear transfer (NT) cloning. Noticeably scarce among the existing rotation techniques is the three-dimensional (3D) rotation of cells on a single chip. Here we present an alternating current (ac) induced electric field-based biochip platform, which has an open-top sub-mm square chamber enclosed by four sidewall electrodes and two bottom electrodes, to achieve rotation about the two axes, thus 3D cell rotation. By applying an ac potential to the four sidewall electrodes, an in-plane (yaw) rotating electric field is generated and in-plane rotation is achieved. Similarly, by applying an ac potential to two opposite sidewall electrodes and the two bottom electrodes, an out-of-plane (pitch) rotating electric field is generated and rolling rotation is achieved. As a prompt proof-of-concept, bottom electrodes were constructed with transparent indium tin oxide (ITO) using the standard lift-off process and the sidewall electrodes were constructed using a low-cost micro-milling process and then assembled to form the chip. Through experiments, we demonstrate rotation of bovine oocytes of ~120 μm diameter about two axes, with the capability of controlling the rotation direction and the rate for each axis through control of the ac potential amplitude, frequency, and phase shift, and cell medium conductivity. The maximum observed rotation rate reached nearly 140° s⁻¹, while a consistent rotation rate reached up to 40° s⁻¹. Rotation rate spectra for zona pellucida-intact and zona pellucida-free oocytes were further compared and found to have no effective difference. This simple, transparent, cheap-to-manufacture, and open-top platform allows additional functional modules to be integrated to become a more powerful cell manipulation system.

  18. Photometrical Research of GSS ≪INTELSAT 10-02≫

    NASA Astrophysics Data System (ADS)

    Sukhov, P. P.; Karpenko, G. F.; Epishev, V. P.; Motrunych, I. I.

    On example of the studies the obtained coordinate and photometrical data GSS ≪Intelsat 10-02≫ is shown as possible surveillance with the help of ground-based optical facilities dynamic state satellite and his behaviors on orbit. The analysis of variation character of the light curves in B,V,R filters, time intervals between the flashes, the color indexes variation shows that the systems of stabilization of the platform, the transceiving antennas and the solar panels worked in operating normal mode during the dates of observation. The solar panels orientation relative to the Sun maintains well enough, rotated practically along the equtor plane tracking the Sun's path (the Earth's rotation). Orientation to axis of the rotation of the platform practically remains to be unchanged to direction on the centre of the masses of the Earth.

  19. First order coupled dynamic model of flexible space structures with time-varying configurations

    NASA Astrophysics Data System (ADS)

    Wang, Jie; Li, Dongxu; Jiang, Jianping

    2017-03-01

    This paper proposes a first order coupled dynamic modeling method for flexible space structures with time-varying configurations for the purpose of deriving the characteristics of the system. The model considers the first time derivative of the coordinate transformation matrix between the platform's body frame and the appendage's floating frame. As a result it can accurately predict characteristics of the system even if flexible appendages rotate with complex trajectory relative to the rigid part. In general, flexible appendages are fixed on the rigid platform or forced to rotate with a slow angular velocity. So only the zero order of the transformation matrix is considered in conventional models. However, due to neglecting of time-varying terms of the transformation matrix, these models introduce severe error when appendages, like antennas, for example, rotate with a fast speed relative to the platform. The first order coupled dynamic model for flexible space structures proposed in this paper resolve this problem by introducing the first time derivative of the transformation matrix. As a numerical example, a central core with a rotating solar panel is considered and the results are compared with those given by the conventional model. It has been shown that the first order terms are of great importance on the attitude of the rigid body and dynamic response of the flexible appendage.

  20. Difference in knee rotation between total and unicompartmental knee arthroplasties during stair climbing.

    PubMed

    Jung, Myung-Chul; Chung, Jun Young; Son, Kwang-Hyun; Wang, Hui; Hwang, Jaejin; Kim, Jay Joong; Kim, Joon Ho; Min, Byoung-Hyun

    2014-08-01

    The purpose of this study was to compare knee kinematics during stair walking in patients with simultaneous total knee arthroplasty (TKA) and unicompartmental knee arthroplasties (UKA). It was hypothesized that UKA would reproduce more normalized knee kinematics than TKA during stair ascent and descent. Six patients who received UKA in one knee and TKA in the other knee were included in the study. For this study, a four-step staircase was assembled with two force platforms being positioned at the centre of the second and third steps. Each patient was attached with 16 reflective markers at both lower extremities and was asked to perform five roundtrip trials of stair climbing. Kinematic parameters including stance duration, knee angle, vertical ground reaction force (GRF), joint reaction force, and moments were obtained and analysed using a10-camera motion system (VICON, Oxford, UK). Nonparametric Friedman test was used to compare the results between two arthroplasty methods and between stair ascent and descent. Compared to TKA, UKA knees exhibited significantly greater degree of rotation in transverse planes (5.0 degrees during ascent and 6.0 degrees during descent on average), but showed no difference in terms of the other parameters. When comparing the results during stair ascent with descent, overall greater knee angle, vertical GRF, joint reaction force, and moment were observed during stair descent. Both UKA and TKA knees have shown overall similar knee kinematics, though UKA knee may allow greater degree of rotation freedom, which resembles normal knee kinematics during stair walking.

  1. Report on the Second ARM Mobile Facility (AMF2) Stabilization Platform: Control Strategy and Implementation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coulter, Richard J.; Martin, Timothy J.

    One of the primary objectives of the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) Climate Research Facility’s second Mobile Facility (AMF2) is to obtain reliable measurements from ocean-going vessels. A pillar of the AMF2 strategy in this effort is the use of a stable platform for those instruments that 1) need to look directly at, or be shaded from, direct sunlight or 2) require a truly vertical orientation. Some ARM instruments that fall into these categories include the Multi-Filter Rotating Shadow Band Radiometer (MFRSR) and the Total Sky Imager (TSI), both of which have a shadow band mechanism, upward-lookingmore » radiometry that should be exposed only to the sky, a Microwave Radiometer (MWR) that looks vertically and at specified tilt angles, and vertically pointing radars, for which the vertical component of motion is critically important. During the design and construction phase of AMF2, an inexpensive stable platform was purchased to perform the stabilization tasks for some of these instruments. Computer programs were developed to communicate with the platform controller and with an inertial measurements platform that measures true ship motion components (roll, pitch, yaw, surge, sway, and heave). The platform was then tested on a 3-day cruise aboard the RV Connecticut during June 16-18, 2010, off the east coast of the United States. This initial test period was followed by continued development of the platform control strategy and implementation as time permitted. This is a report of the results of these efforts and the critical points in moving forward.« less

  2. Deep subwavelength fourfold rotationally symmetric split-ring-resonator metamaterials for highly sensitive and robust biosensing platform

    PubMed Central

    Tobing, Landobasa Y. M.; Tjahjana, Liliana; Zhang, Dao Hua; Zhang, Qing; Xiong, Qihua

    2013-01-01

    Metamaterials provide a good platform for biochemical sensing due to its strong field localization at nanoscale. In this work, we show that electric and magnetic resonant modes in split-ring-resonator (SRR) can be efficiently excited under unpolarized light illumination when the SRRs are arranged in fourfold rotationally symmetric lattice configuration. The fabrication and characterization of deep subwavelength (~λ/15) gold-based SRR structures with resonator size as small as ~ 60 nm are reported with magnetic resonances in Vis-NIR spectrum range. The feasibility for sensing is demonstrated with refractive index sensitivity as high as ~ 636 nm/RIU. PMID:23942416

  3. Robotic follow system and method

    DOEpatents

    Bruemmer, David J [Idaho Falls, ID; Anderson, Matthew O [Idaho Falls, ID

    2007-05-01

    Robot platforms, methods, and computer media are disclosed. The robot platform includes perceptors, locomotors, and a system controller, which executes instructions for a robot to follow a target in its environment. The method includes receiving a target bearing and sensing whether the robot is blocked front. If the robot is blocked in front, then the robot's motion is adjusted to avoid the nearest obstacle in front. If the robot is not blocked in front, then the method senses whether the robot is blocked toward the target bearing and if so, sets the rotational direction opposite from the target bearing, and adjusts the rotational velocity and translational velocity. If the robot is not blocked toward the target bearing, then the rotational velocity is adjusted proportional to an angle of the target bearing and the translational velocity is adjusted proportional to a distance to the nearest obstacle in front.

  4. Independent walking as a major skill for the development of anticipatory postural control: evidence from adjustments to predictable perturbations.

    PubMed

    Cignetti, Fabien; Zedka, Milan; Vaugoyeau, Marianne; Assaiante, Christine

    2013-01-01

    Although there is suggestive evidence that a link exists between independent walking and the ability to establish anticipatory strategy to stabilize posture, the extent to which this skill facilitates the development of anticipatory postural control remains largely unknown. Here, we examined the role of independent walking on the infants' ability to anticipate predictable external perturbations. Non-walking infants, walking infants and adults were sitting on a platform that produced continuous rotation in the frontal plane. Surface electromyography (EMG) of neck and lower back muscles and the positions of markers located on the platform, the upper body and the head were recorded. Results from cross-correlation analysis between rectified and filtered EMGs and platform movement indicated that although muscle activation already occurred before platform movement in non-walking infants, only walking infants demonstrated an adult-like ability for anticipation. Moreover, results from further cross-correlation analysis between segmental angular displacement and platform movement together with measures of balance control at the end-points of rotation of the platform evidenced two sorts of behaviour. The adults behaved as a non-rigid non-inverted pendulum, rather stabilizing head in space, while both the walking and non-walking infants followed the platform, behaving as a rigid inverted pendulum. These results suggest that the acquisition of independent walking plays a role in the development of anticipatory postural control, likely improving the internal model for the sensorimotor control of posture. However, despite such improvement, integrating the dynamics of an external object, here the platform, within the model to maintain balance still remains challenging in infants.

  5. Analysis of the Motion Control Methods for Stratospheric Balloon-Borne Gondola Platform

    NASA Astrophysics Data System (ADS)

    Wang, H. H.; Yuan, Z. H.; Wu, J.

    2006-10-01

    At present, gondola platform is one of the stratospheric balloon-borne platforms being in research focus at home and overseas. Comparing to other stratospheric balloon-borne platforms, such as airship platform, gondola platform has advantages of higher stability, rapid in motion regulation and lower energy cost but disadvantages of less supporting capacity and be incapable of fixation. While all platforms have the same goal of keeping them at accurate angle and right pose for the requirements of instruments and objects installed in the platforms, when platforms rotate round the ground level perpendicular. That is accomplishing motion control. But, platform control system has factors of low damper, excessive and uncertain disturbances by the reason of its being hung over balloon in the air, it is hard to achieve the desired control precision because platform is ease to deviate its benchmark motion. Thus, in the controlling procedure in order to get higher precision, it is crucial to perceive the platform's swing synchronously and rapidly, and restrain the influence of disturbances effectively, keep the platform's pose steadily. Furthermore, while the platform in the air regard control center in the ground as reference object, it is ultimate to select a appropriate reference frame and work out the coordinates and implement the adjustment by the PC104 controller. This paper introduces the methods of the motion control based on stratospheric balloon-borne gondola platform. Firstly, this paper compares the characteristic of the flywheel and CMG and specifies the key methods of obtaining two significant states which are 'orientation stability' state and 'orientation tracking' state for platform motion control procedure using CMG as the control actuator. These two states reduce the deviation amplitude of rotation and swing of gondola's motion relative to original motion due to stratospheric intense atmosphere disturbance. We define it as the first procedure. In next procedure, we use the transfer matrix of earth reference frame to geographic reference frame to transform the data measured by the magnetic orientation sensors and the gyroscope to the space orientations, then the PC104 controller use the space orientations value as feedback to complete revises.

  6. Atom interferometric gravity gradiometer: Disturbance compensation and mobile gradiometry

    NASA Astrophysics Data System (ADS)

    Mahadeswaraswamy, Chetan

    First ever mobile gravity gradient measurement based on Atom Interferometric sensors has been demonstrated. Mobile gravity gradiometers play a significant role in high accuracy inertial navigation systems in order to distinguish inertial acceleration and acceleration due to gravity. The gravity gradiometer consists of two atom interferometric accelerometers. In each of the accelerometer an ensemble of laser cooled Cesium atoms is dropped and using counter propagating Raman pulses (pi/2-pi-pi/2) the ensemble is split into two states for carrying out atom interferometry. The interferometer phase is proportional to the specific force experienced by the atoms which is a combination of inertial acceleration and acceleration due to gravity. The difference in phase between the two atom interferometric sensors is proportional to gravity gradient if the platform does not undergo any rotational motion. However, any rotational motion of the platform induces spurious gravity gradient measurements. This apparent gravity gradient due to platform rotation is considerably different for an atom interferometric sensor compared to a conventional force rebalance type sensor. The atoms are in free fall and are not influenced by the motion of the case except at the instants of Raman pulses. A model for determining apparent gravity gradient due to rotation of platform was developed and experimentally verified for different frequencies. This transfer function measurement also lead to the development of a new technique for aligning the Raman laser beams with the atom clusters to within 20 mu rad. This gravity gradiometer is situated in a truck for the purpose of undertaking mobile surveys. A disturbance compensation system was designed and built in order to compensate for the rotational disturbances experienced on the floor of a truck. An electric drive system was also designed specifically to be able to move the truck in a uniform motion at very low speeds of about 1cm/s. A 250 x10-9 s-2 gravity gradient signature due to an underground void at Hansen Experimental Physics Building at Stanford was successfully measured using this mobile gradiometer.

  7. Noncontact Measurement Of Sizes And Eccentricities Of Holes

    NASA Technical Reports Server (NTRS)

    Chern, Engmin J.

    1993-01-01

    Semiautomatic eddy-current-probe apparatus makes noncontact measurements of nominally round holes in electrically conductive specimens and processes measurement data into diameters and eccentricities of holes. Includes x-y translation platform, which holds specimen and moves it horizontally. Probe mounted on probe scanner, positioning probe along vertical (z) direction and rotates probe about vertical axis at preset low speed. Eddy-current sensing coil mounted in side of probe near tip. As probe rotates, impedance analyzer measures electrical impedance (Z) of coil as function of instantaneous rotation angle. Translation and rotation mechanisms and impedance analyzer controlled by computer, which also processes impedance-measurement data.

  8. Enhanced Faraday rotation in one dimensional magneto-plasmonic structure due to Fano resonance

    NASA Astrophysics Data System (ADS)

    Sadeghi, S.; Hamidi, S. M.

    2018-04-01

    Enhanced Faraday rotation in a new type of magneto-plasmonic structure with the capability of Fano resonance, has been reported theoretically. A magneto-plasmonic structure composed of a gold corrugated layer deposited on a magneto-optically active layer was studied by means of Lumerical software based on finite-difference time-domain. In our proposed structure, plasmonic Fano resonance and localized surface plasmon have induced enhancement in magneto-optical Faraday rotation. It is shown that the influence of geometrical parameters in gold layer offers a desirable platform for engineering spectral position of Fano resonance and enhancement of Faraday rotation.

  9. 29 CFR 1910.67 - Vehicle-mounted elevating and rotating work platforms.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (b) General requirements. (1) Unless otherwise provided in this section, aerial devices (aerial lifts.... Aerial lifts acquired for use before July 1, 1975 which do not meet the requirements of ANSI A92.2—1969... lifts whether or not they are capable of rotating about a substantially vertical axis. (2) Aerial lifts...

  10. 29 CFR 1910.67 - Vehicle-mounted elevating and rotating work platforms.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .... (b) General requirements. (1) Unless otherwise provided in this section, aerial devices (aerial lifts.... Aerial lifts acquired for use before July 1, 1975 which do not meet the requirements of ANSI A92.2—1969... lifts whether or not they are capable of rotating about a substantially vertical axis. (2) Aerial lifts...

  11. Flywheels Would Compensate for Rotor Imbalance

    NASA Technical Reports Server (NTRS)

    Hrastar, J. A. S.

    1982-01-01

    Spinning flywheels within rotor can null imbalance forces in rotor. Flywheels axes are perpendicular to each other and to rotor axis. Feedback signals from accelerometers or strain gages in platform control flywheel speeds and rotation directions. Concept should be useful for compensating rotating bodies on Earth. For example, may be applied to large industrial centrifuge, particularly if balance changes during operation.

  12. Inertial-space disturbance rejection for robotic manipulators

    NASA Technical Reports Server (NTRS)

    Holt, Kevin

    1992-01-01

    The disturbance rejection control problem for a 6-DOF (degree of freedom) PUMA manipulator mounted on a 3-DOF platform is investigated. A control algorithm is designed to track the desired position and attitude of the end-effector in inertial space, subject to unknown disturbances in the platform axes. Conditions for the stability of the closed-loop system are derived. The performance of the controller is compared for step, sinusoidal, and random disturbances in the platform rotational axis and in the neighborhood of kinematic singularities.

  13. Humanoid monocular stereo measuring system with two degrees of freedom using bionic optical imaging system

    NASA Astrophysics Data System (ADS)

    Du, Jia-Wei; Wang, Xuan-Yin; Zhu, Shi-Qiang

    2017-10-01

    Based on the process by which the spatial depth clue is obtained by a single eye, a monocular stereo vision to measure the depth information of spatial objects was proposed in this paper and a humanoid monocular stereo measuring system with two degrees of freedom was demonstrated. The proposed system can effectively obtain the three-dimensional (3-D) structure of spatial objects of different distances without changing the position of the system and has the advantages of being exquisite, smart, and flexible. The bionic optical imaging system we proposed in a previous paper, named ZJU SY-I, was employed and its vision characteristic was just like the resolution decay of the eye's vision from center to periphery. We simplified the eye's rotation in the eye socket and the coordinated rotation of other organs of the body into two rotations in the orthogonal direction and employed a rotating platform with two rotation degrees of freedom to drive ZJU SY-I. The structure of the proposed system was described in detail. The depth of a single feature point on the spatial object was deduced, as well as its spatial coordination. With the focal length adjustment of ZJU SY-I and the rotation control of the rotation platform, the spatial coordinates of all feature points on the spatial object could be obtained and then the 3-D structure of the spatial object could be reconstructed. The 3-D structure measurement experiments of two spatial objects with different distances and sizes were conducted. Some main factors affecting the measurement accuracy of the proposed system were analyzed and discussed.

  14. Sports activity following total knee arthroplasty in patients older than 60 years.

    PubMed

    Mayr, Hermann O; Reinhold, Maik; Bernstein, Anke; Suedkamp, Norbert P; Stoehr, Amelie

    2015-01-01

    In a retrospective study with a population over 65 years, sports activity was conducted 6 years after cruciate retaining (CR) total condylar knee arthroplasty (TKA) with rotating platform (RP). Eighty-one Patients (71.8±5.4years) were examined at follow-up 6.4±0.9 years postoperative. Sport was practiced 5.3 hours every week in mean. Patients were active in sports 3.5times per week. Twenty-five percent performed high impact sports, 47% medium impact sports and 52% low impact sports at follow-up. In KOOS sports 60±28 was reached, in WOMAC 12.1±15.1. It can be concluded that in this population 50% of patients were active in medium and low impact sport 6 years after surgery. However, a quarter of patients were also active in high impact sports. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Genome-wide association study for rotator cuff tears identifies two significant single-nucleotide polymorphisms.

    PubMed

    Tashjian, Robert Z; Granger, Erin K; Farnham, James M; Cannon-Albright, Lisa A; Teerlink, Craig C

    2016-02-01

    The precise etiology of rotator cuff disease is unknown, but prior evidence suggests a role for genetic factors. Limited data exist identifying specific genes associated with rotator cuff tearing. The purpose of this study was to identify specific genes or genetic variants associated with rotator cuff tearing by a genome-wide association study with an independent set of rotator cuff tear cases. A set of 311 full-thickness rotator cuff tear cases genotyped on the Illumina 5M single-nucleotide polymorphism (SNP) platform were used in a genome-wide association study with 2641 genetically matched white population controls available from the Illumina iControls database. Tests of association were performed with GEMMA software at 257,558 SNPs that compose the intersection of Illumina SNP platforms and that passed general quality control metrics. SNPs were considered significant if P < 1.94 × 10(-7) (Bonferroni correction: 0.05/257,558). Tests of association revealed 2 significantly associated SNPs, one occurring in SAP30BP (rs820218; P = 3.8E-9) on chromosome 17q25 and another occurring in SASH1 (rs12527089; P = 1.9E-7) on chromosome 6q24. This study represents the first attempt to identify genetic factors influencing rotator cuff tearing by a genome-wide association study using a dense/complete set of SNPs. Two SNPs were significantly associated with rotator cuff tearing, residing in SAP30BP on chromosome 17 and SASH1 on chromosome 6. Both genes are associated with the cellular process of apoptosis. Identification of potential genes or genetic variants associated with rotator cuff tearing may help in identifying individuals at risk for the development of rotator cuff tearing. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Strategies utilized to transfer weight during knee flexion and extension with rotation for individuals with a total knee replacement.

    PubMed

    Ferris, Lauren A; Denney, Linda M; Maletsky, Lorin P

    2013-02-01

    Functional activities in daily life can require squatting and shifting body weight during transverse plane rotations. Stability of the knee can be challenging for people with a total knee replacement (TKR) due to reduced proprioception, nonconforming articular geometry, muscle strength, and soft tissue weakness. The objective of this study was to identify strategies utilized by individuals with TKR in double-stance transferring load during rotation and flexion. Twenty-three subjects were recruited for this study: 11 TKR subjects (age: 65 ± 6 years; BMI 27.4 ± 4.1) and 12 healthy subjects (age: 63 ± 7; BMI 24.6 ± 3.8). Each subject completed a novel crossover button push task where rotation, flexion, and extension of the knee were utilized. Each subject performed two crossover reaching tasks where the subject used the opposite hand to cross over their body and press a button next to either their shoulder (high) or knee (low), then switched hands and rotated to press the opposite button, either low or high. The two tasks related to the order they pressed the buttons while crossing over, either low-to-high (L2H) or high-to-low (H2L). Force platforms measured ground reaction forces under each foot, which were then converted to lead force ratios (LFRs) based on the total force. Knee flexion angles were also measured. No statistical differences were found in the LFRs during the H2L and L2H tasks for the different groups, although differences in the variation of the loading within subjects were noted. A significant difference was found between healthy and unaffected knee angles and a strong trend between healthy and affected subject's knee angles in both H2L and L2H tasks. Large variations in the LFR at mid-task in the TKR subjects suggested possible difficulties in maintaining positional stability during these tasks. The TKR subjects maintained more of an extended knee, which is a consistent quadriceps avoidance strategy seen by other researchers in different tasks. These outcomes suggest that individuals with a TKR utilize strategies, such as keeping an extended knee, to achieve rotary tasks during knee flexion and extension. Repeated compensatory movements could result in forces that may cause difficulty over time in the hip joints or low back. Early identification of these strategies could improve TKR success and the return to activities of daily living that involve flexion and rotation.

  17. Simulation of cooperating robot manipulators on a mobile platform

    NASA Technical Reports Server (NTRS)

    Murphy, Stephen H.; Wen, John Ting-Yung; Saridis, George N.

    1991-01-01

    The dynamic equations of motion are presented for two or more cooperating manipulators on a freely moving mobile platform. The system of cooperating robot manipulators forms a closed kinematic chain where the force of interaction must be included in the formulation of robot and platform dynamics. The formulation includes the full dynamic interactions from arms to platform and arm tip to arm tip, and the possible translation and rotation of the platform. The equations of motion are shown to be identical in structure to the fixed-platform cooperative manipulator dynamics. The number of DOFs of the system is sufficiently large to make recursive dynamic calculation methods potentially more efficient than closed-form solutions. A complete simulation with two 6-DOF manipulators of a free-floating platform is presented along a with a multiple-arm controller to position the common load.

  18. STS-30 Atlantis, OV-104, at KSC LC Pad 39B atop mobile launcher platform

    NASA Technical Reports Server (NTRS)

    1989-01-01

    STS-30 Atlantis, Orbiter Vehicle (OV) 104, arrives at Kennedy Space Center (KSC) Launch Complex (LC) Pad 39B atop mobile launcher platform. The fixed service structure (FSS) towers above OV-104, its external tank (ET), and its solid rocket boosters (SRBs). The rotating service structure (RSS) is retracted. The launch tower catwalks are also retracted.

  19. Rotation and direction judgment from visual images head-slaved in two and three degrees-of-freedom.

    PubMed

    Adelstein, B D; Ellis, S R

    2000-03-01

    The contribution to spatial awareness of adding a roll degree-of-freedom (DOF) to telepresence camera platform yaw and pitch was examined in an experiment where subjects judged direction and rotation of stationary target markers in a remote scene. Subjects viewed the scene via head-slaved camera images in a head-mounted display. Elimination of the roll DOF affected rotation judgment, but only at extreme yaw and pitch combinations, and did not affect azimuth and elevation judgement. Systematic azimuth overshoot occurred regardless of roll condition. Observed rotation misjudgments are explained by kinematic models for eye-head direction of gaze.

  20. Body surface posture evaluation: construction, validation and protocol of the SPGAP system (Posture evaluation rotating platform system).

    PubMed

    Schwertner, Debora Soccal; Oliveira, Raul; Mazo, Giovana Zarpellon; Gioda, Fabiane Rosa; Kelber, Christian Roberto; Swarowsky, Alessandra

    2016-05-04

    Several posture evaluation devices have been used to detect deviations of the vertebral column. However it has been observed that the instruments present measurement errors related to the equipment, environment or measurement protocol. This study aimed to build, validate, analyze the reliability and describe a measurement protocol for the use of the Posture Evaluation Rotating Platform System (SPGAP, Brazilian abbreviation). The posture evaluation system comprises a Posture Evaluation Rotating Platform, video camera, calibration support and measurement software. Two pilot studies were carried out with 102 elderly individuals (average age 69 years old, SD = ±7.3) to establish a protocol for SPGAP, controlling the measurement errors related to the environment, equipment and the person under evaluation. Content validation was completed with input from judges with expertise in posture measurement. The variation coefficient method was used to validate the measurement by the instrument of an object with known dimensions. Finally, reliability was established using repeated measurements of the known object. Expert content judges gave the system excellent ratings for content validity (mean 9.4 out of 10; SD 1.13). The measurement of an object with known dimensions indicated excellent validity (all measurement errors <1 %) and test-retest reliability. A total of 26 images were needed to stabilize the system. Participants in the pilot studies indicated that they felt comfortable throughout the assessment. The use of only one image can offer measurements that underestimate or overestimate the reality. To verify the images of objects with known dimensions the values for the width and height were, respectively, CV 0.88 (width) and 2.33 (height), SD 0.22 (width) and 0.35 (height), minimum and maximum values 24.83-25.2 (width) and 14.56 - 15.75 (height). In the analysis of different images (similar) of an individual, greater discrepancies were observed in the values found. The cervical index, for example, presented minimum and maximum values of 15.38 and 37.5, a coefficient of variation of 0.29 and a standard deviation of 6.78. The SPGAP was shown to be a valid and reliable instrument for the quantitative analysis of body posture with applicability and clinical use, since it managed to reduce several measurement errors, amongst which parallax distortion.

  1. Hip rotation range of motion in sitting and prone positions in healthy Japanese adults

    PubMed Central

    Han, Heonsoo; Kubo, Akira; Kurosawa, Kazuo; Maruichi, Shizuka; Maruyama, Hitoshi

    2015-01-01

    [Purpose] The aim of this study was to elucidate the difference in hip external and internal rotation ranges of motion (ROM) between the prone and sitting positions. [Subjects] The subjects included 151 students. [Methods] Hip rotational ROM was measured with the subjects in the prone and sitting positions. Two-way repeated measures analysis of variance (ANOVA) was used to analyze ipsilateral hip rotation ROM in the prone and sitting positions in males and females. The total ipsilateral hip rotation ROM was calculated by adding the measured values for external and internal rotations. [Results] Ipsilateral hip rotation ROM revealed significant differences between two positions for both left and right internal and external rotations. Hip rotation ROM was significantly higher in the prone position than in the sitting position. Hip rotation ROM significantly differed between the men and women. Hip external rotation ROM was significantly higher in both positions in men; conversely, hip internal rotation ROM was significantly higher in both positions in women. [Conclusion] Hip rotation ROM significantly differed between the sexes and between the sitting and prone positions. Total ipsilateral hip rotation ROM, total angle of external rotation, and total angle of internal rotation of the left and right hips greatly varied, suggesting that hip joint rotational ROM is widely distributed. PMID:25729186

  2. Event-triggered logical flow control for comprehensive process integration of multi-step assays on centrifugal microfluidic platforms.

    PubMed

    Kinahan, David J; Kearney, Sinéad M; Dimov, Nikolay; Glynn, Macdara T; Ducrée, Jens

    2014-07-07

    The centrifugal "lab-on-a-disc" concept has proven to have great potential for process integration of bioanalytical assays, in particular where ease-of-use, ruggedness, portability, fast turn-around time and cost efficiency are of paramount importance. Yet, as all liquids residing on the disc are exposed to the same centrifugal field, an inherent challenge of these systems remains the automation of multi-step, multi-liquid sample processing and subsequent detection. In order to orchestrate the underlying bioanalytical protocols, an ample palette of rotationally and externally actuated valving schemes has been developed. While excelling with the level of flow control, externally actuated valves require interaction with peripheral instrumentation, thus compromising the conceptual simplicity of the centrifugal platform. In turn, for rotationally controlled schemes, such as common capillary burst valves, typical manufacturing tolerances tend to limit the number of consecutive laboratory unit operations (LUOs) that can be automated on a single disc. In this paper, a major advancement on recently established dissolvable film (DF) valving is presented; for the very first time, a liquid handling sequence can be controlled in response to completion of preceding liquid transfer event, i.e. completely independent of external stimulus or changes in speed of disc rotation. The basic, event-triggered valve configuration is further adapted to leverage conditional, large-scale process integration. First, we demonstrate a fluidic network on a disc encompassing 10 discrete valving steps including logical relationships such as an AND-conditional as well as serial and parallel flow control. Then we present a disc which is capable of implementing common laboratory unit operations such as metering and selective routing of flows. Finally, as a pilot study, these functions are integrated on a single disc to automate a common, multi-step lab protocol for the extraction of total RNA from mammalian cell homogenate.

  3. Acoustic Dirac degeneracy and topological phase transitions realized by rotating scatterers

    NASA Astrophysics Data System (ADS)

    Wen, Xinhua; Qiu, Chunyin; Lu, Jiuyang; He, Hailong; Ke, Manzhu; Liu, Zhengyou

    2018-03-01

    The artificial crystals for classical waves provide a good platform to explore the topological physics proposed originally in condensed matter systems. In this paper, acoustic Dirac degeneracy is realized by simply rotating the scatterers in sonic crystals, where the degeneracy is induced accidentally by modulating the scattering strength among the scatterers during the rotation process. This gives a flexible way to create a topological phase transition in acoustic systems. Edge states are further observed along the interface separating the two topologically distinct gapped sonic crystals.

  4. Tiltmeter leveling mechanism

    DOEpatents

    Hunter, Steven L.; Boro, Carl O.; Farris, Alvis

    2002-01-01

    A tiltmeter device having a pair of orthogonally disposed tilt sensors that are levelable within an inner housing containing the sensors. An outer housing can be rotated to level at least one of the sensor pair while the inner housing can be rotated to level the other sensor of the pair. The sensors are typically rotated up to about plus or minus 100 degrees. The device is effective for measuring tilts in a wide range of angles of inclination of wells and can be employed to level a platform containing a third sensor.

  5. Computing Dynamics Of A Robot Of 6+n Degrees Of Freedom

    NASA Technical Reports Server (NTRS)

    Quiocho, Leslie J.; Bailey, Robert W.

    1995-01-01

    Improved formulation speeds and simplifies computation of dynamics of robot arm of n rotational degrees of freedom mounted on platform having three translational and three rotational degrees of freedom. Intended for use in dynamical modeling of robotic manipulators attached to such moving bases as spacecraft, aircraft, vessel, or land vehicle. Such modeling important part of simulation and control of robotic motions.

  6. 33 CFR 149.535 - What are the requirements for rotating beacons on platforms?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... beacon must: (a) Have an effective intensity of at least 15,000 candela; (b) Flash at least once every 20 seconds; (c) Provide a white light signal; (d) Operate in wind speeds of up to 100 knots at a rotation rate that is within 6 percent of the operating speed displayed on the beacon; (e) Have one or more...

  7. 33 CFR 149.535 - What are the requirements for rotating beacons on platforms?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... beacon must: (a) Have an effective intensity of at least 15,000 candela; (b) Flash at least once every 20 seconds; (c) Provide a white light signal; (d) Operate in wind speeds of up to 100 knots at a rotation rate that is within 6 percent of the operating speed displayed on the beacon; (e) Have one or more...

  8. 33 CFR 149.535 - What are the requirements for rotating beacons on platforms?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... beacon must: (a) Have an effective intensity of at least 15,000 candela; (b) Flash at least once every 20 seconds; (c) Provide a white light signal; (d) Operate in wind speeds of up to 100 knots at a rotation rate that is within 6 percent of the operating speed displayed on the beacon; (e) Have one or more...

  9. 33 CFR 149.535 - What are the requirements for rotating beacons on platforms?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... beacon must: (a) Have an effective intensity of at least 15,000 candela; (b) Flash at least once every 20 seconds; (c) Provide a white light signal; (d) Operate in wind speeds of up to 100 knots at a rotation rate that is within 6 percent of the operating speed displayed on the beacon; (e) Have one or more...

  10. 33 CFR 149.535 - What are the requirements for rotating beacons on platforms?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... beacon must: (a) Have an effective intensity of at least 15,000 candela; (b) Flash at least once every 20 seconds; (c) Provide a white light signal; (d) Operate in wind speeds of up to 100 knots at a rotation rate that is within 6 percent of the operating speed displayed on the beacon; (e) Have one or more...

  11. Cost-Effectiveness of Reverse Total Shoulder Arthroplasty Versus Arthroscopic Rotator Cuff Repair for Symptomatic Large and Massive Rotator Cuff Tears.

    PubMed

    Makhni, Eric C; Swart, Eric; Steinhaus, Michael E; Mather, Richard C; Levine, William N; Bach, Bernard R; Romeo, Anthony A; Verma, Nikhil N

    2016-09-01

    To compare the cost-effectiveness within the United States health care system of arthroscopic rotator cuff repair versus reverse total shoulder arthroplasty in patients with symptomatic large and massive rotator cuff tears without cuff-tear arthropathy. An expected-value decision analysis was constructed comparing the costs and outcomes of patients undergoing arthroscopic rotator cuff repair and reverse total shoulder arthroplasty for large and massive rotator cuff tears (and excluding cases of cuff-tear arthropathy). Comprehensive literature search provided input data to extrapolate costs and health utility states for these outcomes. The primary outcome assessed was that of incremental cost-effectiveness ratio (ICER) of reverse total shoulder arthroplasty versus rotator cuff repair. For the base case, both arthroscopic rotator cuff repair and reverse total shoulder were superior to nonoperative care, with an ICER of $15,500/quality-adjusted life year (QALY) and $37,400/QALY, respectively. Arthroscopic rotator cuff repair was dominant over primary reverse total shoulder arthroplasty, with lower costs and slightly improved clinical outcomes. Arthroscopic rotator cuff repair was the preferred strategy as long as the lifetime progression rate from retear to end-stage cuff-tear arthropathy was less than 89%. However, when the model was modified to account for worse outcomes when reverse shoulder arthroplasty was performed after a failed attempted rotator cuff repair, primary reverse total shoulder had superior outcomes with an ICER of $90,000/QALY. Arthroscopic rotator cuff repair-despite high rates of tendon retearing-for patients with large and massive rotator cuff tears may be a more cost-effective initial treatment strategy when compared with primary reverse total shoulder arthroplasty and when assuming no detrimental impact of previous surgery on outcomes after arthroplasty. Clinical judgment should still be prioritized when formulating treatment plans for these patients. LEVEL OF EVIDENCE: Level II, economic decision analysis. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Predictive factor analysis for successful performance of iris recognition-assisted dynamic rotational eye tracking during laser in situ keratomileusis.

    PubMed

    Prakash, Gaurav; Ashok Kumar, Dhivya; Agarwal, Amar; Jacob, Soosan; Sarvanan, Yoga; Agarwal, Athiya

    2010-02-01

    To analyze the predictive factors associated with success of iris recognition and dynamic rotational eye tracking on a laser in situ keratomileusis (LASIK) platform with active assessment and correction of intraoperative cyclotorsion. Interventional case series. Two hundred seventy-five eyes of 142 consecutive candidates underwent LASIK with attempted iris recognition and dynamic rotational tracking on the Technolas 217z100 platform (Techolas Perfect Vision, St Louis, Missouri, USA) at a tertiary care ophthalmic hospital. The main outcome measures were age, gender, flap creation method (femtosecond, microkeratome, epi-LASIK), success of static rotational tracking, ablation algorithm, pulses, and depth; preablation and intraablation rotational activity were analyzed and evaluated using regression models. Preablation static iris recognition was successful in 247 eyes, without difference in flap creation methods (P = .6). Age (partial correlation, -0.16; P = .014), amount of pulses (partial correlation, 0.39; P = 1.6 x 10(-8)), and gender (P = .02) were significant predictive factors for the amount of intraoperative cyclodeviation. Tracking difficulties leading to linking the ablation with a new intraoperatively acquired iris image were more with femtosecond-assisted flaps (P = 2.8 x 10(-7)) and the amount of intraoperative cyclotorsion (P = .02). However, the number of cases having nonresolvable failure of intraoperative rotational tracking was similar in the 3 flap creation methods (P = .22). Intraoperative cyclotorsional activity depends on the age, gender, and duration of ablation (pulses delivered). Femtosecond flaps do not seem to have a disadvantage over microkeratome flaps as far as iris recognition and success of intraoperative dynamic rotational tracking is concerned. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  13. Fast instantaneous center of rotation estimation algorithm for a skied-steered robot

    NASA Astrophysics Data System (ADS)

    Kniaz, V. V.

    2015-05-01

    Skid-steered robots are widely used as mobile platforms for machine vision systems. However it is hard to achieve a stable motion of such robots along desired trajectory due to an unpredictable wheel slip. It is possible to compensate the unpredictable wheel slip and stabilize the motion of the robot using visual odometry. This paper presents a fast optical flow based algorithm for estimation of instantaneous center of rotation, angular and longitudinal speed of the robot. The proposed algorithm is based on Horn-Schunck variational optical flow estimation method. The instantaneous center of rotation and motion of the robot is estimated by back projection of optical flow field to the ground surface. The developed algorithm was tested using skid-steered mobile robot. The robot is based on a mobile platform that includes two pairs of differential driven motors and a motor controller. Monocular visual odometry system consisting of a singleboard computer and a low cost webcam is mounted on the mobile platform. A state-space model of the robot was derived using standard black-box system identification. The input (commands) and the output (motion) were recorded using a dedicated external motion capture system. The obtained model was used to control the robot without visual odometry data. The paper is concluded with the algorithm quality estimation by comparison of the trajectories estimated by the algorithm with the data from motion capture system.

  14. Paleomagnetic Investigations on the Tectonic Evolution of the Southeastern Anatolian Ophiolites in Late Cretaceous

    NASA Astrophysics Data System (ADS)

    Cengiz Cinku, M.; Karabulut, S.; Parlak, O.; Cabuk, B. S.; Ustaömer, T.; Hisarli, M. Z.

    2016-12-01

    Two E-W trending ophiolite belts crop out in SE Turkey, The southerly located ophiolites (Hatay, Koçali) were emplaced onto the Arabian Platform in Late Cretaceous whereas the northerly located ophiolites (Göksun, İspendere, Kömürhan, Guleman) were underthrust the S Tauride margin (i.e. Malatya-Keban Platform) in Late Cretaceous. Here we report our first paleomagnetic results from 155 different sites which was was focused on to the sheeted dyke complex, cumulate gabbros and extrusive sequences of each ophiolite from the N and S belts, while the cover units where sampled to distinguish emplacement related tectonic rotations from post-emplacement tectonic rotations. Rock magnetic experiments showed evidence of magnetite/titanomagnetite as the main magnetic carriers at the majority of sites. Progressive thermal and alternating demagnetization revealed that the characteristic remanent component is removed between 500 and 580 °C or 30-100 mT, respectively. Our new paleomagnetic results from the ophiolitic rocks emplaced in Arabian platform and the SE Anatolia show important implications to the spreading centre of the former ocean (s). Large counterclockwise rotations up to 100° are obtained from the sheeded dykes of the Hatay ophiolite in the Arabian plate with a paleolatitude of 16°, in contrast to the sheeded dykes of the Göksun ophiolite emplaced in the SE Anatolian with clockwise rotation of 90° and a paleolatitude of 22°. The relative movement of the ophiolitic series show their emplacement in the different zones. This study was financially supported by the project of the Scientific and Technical Research Council of Turkey (TUBITAK) with Project number 114R024.

  15. Partnering with patients using social media to develop a hypertension management instrument.

    PubMed

    Kear, Tamara; Harrington, Magdalena; Bhattacharya, Anand

    2015-09-01

    Hypertension is a lifelong condition; thus, long-term adherence to lifestyle modification, self-monitoring, and medication regimens remains a challenge for patients. The aim of this study was to develop a patient-reported hypertension instrument that measured attitudes, lifestyle behaviors, adherence, and barriers to hypertension management using patient-reported outcome data. The study was conducted using the Open Research Exchange software platform created by PatientsLikeMe. A total of 360 participants completed the psychometric phase of the study; incomplete responses were obtained from 147 patients, and 150 patients opted out. Principal component analysis with orthogonal (varimax) rotation was executed on a data set with all completed responses (N = 249) and applied to 43 items. Based on the review of the factor solution, eigenvalues, and item loadings, 16 items were eliminated and model with 29 items was tested. The process was repeated two more times until final model with 14 items was established. In interpreting the rotated factor pattern, an item was said to load on any given component if the factor loading was ≥0.40 for that component and was <0.40 for the other. In addition to the newly generated instrument, demographic and self-reported clinical characteristics of the study participants such as the type of prescribed hypertension medications, frequency of blood pressure monitoring, and comorbid conditions were examined. The Open Research Exchange platform allowed for ongoing input from patients through each stage of the 14-item instrument development. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Design principles of a rotating medium speed mechanism

    NASA Technical Reports Server (NTRS)

    Hostenkamp, R. G.; Achtermann, E.; Bentall, R. H.

    1976-01-01

    Design principles of a medium speed mechanism (MSM) are presented, including discussion on the relative merits of beryllium and aluminium as structural materials. Rotating at a speed of 60 rpm, the application envisaged for the MSM was as a despin bearing for the despun platform or despun antenna of a spin stabilized satellite. The MSM was built and tested to qualification level and is currently undergoing real time life testing.

  17. Optical binding of two microparticles levitated in vacuum

    NASA Astrophysics Data System (ADS)

    Arita, Yoshihiko; Wright, Ewan M.; Dholakia, Kishan

    2017-04-01

    Optical binding refers to an optically mediated inter-particle interaction that creates new equilibrium positions for closely spaced particles [1-5]. Optical binding of mesoscopic particles levitated in vacuum can pave the way towards the realisation of a large scale quantum bound array in cavity-optomechanics [6-9]. Recently we have demonstrated trapping and rotation of two mesoscopic particles in vacuum using a spatial-light-modulator-based approach to trap more than one particle, induce controlled rotation of individual particles, and mediate interparticle separation [10]. By trapping and rotating two vaterite particles, we observe intensity modulation of the scattered light at the sum and difference frequencies with respect to the individual rotation rates. This first demonstration of optical interference between two microparticles in vacuum has lead to a platform to explore optical binding. Here we demonstrate for the first time optically bound two microparticles mediated by light scattering in vacuum. We investigate autocorrelations between the two normal modes of oscillation, which are determined by the centre-of-mass and the relative positions of the two-particle system. In situ determination of the optical restoring force acting on the bound particles are based on measurement of the oscillation frequencies of the autocorrelation functions of the two normal modes, thereby providing a powerful and original platform to explore multiparticle entanglement in cavity-optomechanics.

  18. Glenohumeral joint rotation range of motion in competitive swimmers.

    PubMed

    Riemann, Bryan L; Witt, Joe; Davies, George J

    2011-08-01

    Much research has examined shoulder range of motion adaptations in overhead-unilateral athletes. Based on the void examining overhead-bilateral athletes, especially competitive swimmers, we examined shoulder external rotation, isolated internal rotation, composite internal rotation, and total arc of motion range of motion of competitive swimmers. The range of motion of registered competitive swimmers (n = 144, age = 12-61 years) was compared by limb (dominant, non-dominant), sex, and age group (youth, high school, college, masters). Significantly (P < 0.05) greater dominant external rotation was observed for both men and women high school and college swimmers, youth women swimmers, and men masters swimmers compared with the non-dominant limb. The isolated internal rotation (glenohumeral rotation), composite internal rotation (glenohumeral rotation plus scapulothoracic protraction), and total arc of motion (external rotation plus composite internal rotation) of the non-dominant limb was significantly greater than that of the dominant limb by sex and age group. Youth and high school swimmers demonstrated significantly greater composite internal rotation than college and masters swimmers. Youth swimmers displayed significantly greater total arc of motion than all other age groups. These data will aid in the interpretation of shoulder range of motion values in competitive swimmers during preseason screenings, injury evaluations and post-rehabilitation programmes, with the results suggesting that differences exist in bilateral external rotation, isolated internal rotation, composite internal rotation, and total arc of motion range of motion.

  19. The degrees to which transtrochanteric rotational osteotomy moves the region of osteonecrotic femoral head out of the weight-bearing area as evaluated by computer simulation.

    PubMed

    Chen, Weng-Pin; Tai, Ching-Lung; Tan, Chih-Feng; Shih, Chun-Hsiung; Hou, Shun-Hsin; Lee, Mel S

    2005-01-01

    Transtrochanteric rotational osteotomy is a technical demanding procedure. Currently, the pre-operative planning of the transtrochanteric rotational osteotomy is mostly based on X-ray images. The surgeons would need to reconstruct the three-dimensional structure of the femoral head and the necrosis in their mind. This study develops a simulation platform using computer models based on the computed tomography images of the femoral head to evaluate the degree to which transtrochanteric rotational osteotomy moves the region of osteonecrotic femoral head out of the weight-bearing area in stance and gait cycle conditions. Based on this simulation procedure, the surgeons would be better informed before the surgery and the indication can be carefully assessed. A case with osteonecrosis involving 15% of the femoral head was recruited. Virtual models with the same size lesion but at different locations were devised. Computer models were created using SolidWorks 2000 CAD software. The area ratio of weight-bearing zone occupied by the necrotic lesion on two conditions, stance and gait cycle, were measured after surgery simulations. For the specific case and virtual models devised in this study, computer simulation showed the following two findings: (1) The degrees needed to move the necrosis out of the weight-bearing zone in stance were less by anterior rotational osteotomy as compared to that of posterior rotational osteotomy. However, the necrotic region would still overlap with the weight-bearing area during gait cycle. (2) Because the degrees allowed for posterior rotation were less restricted than anterior rotation, posterior rotational osteotomies were often more effective to move the necrotic region out of the weight-bearing area during gait cycle. The computer simulation platform by registering actual CT images is a useful tool to assess the direction and degrees needed for transtrochanteric rotational osteotomy. Although the results indicated that anterior rotational osteotomy was more effective to move the necrosis out of the weight-bearing zone in stance for models devised in this study, in circumstances where the necrotic region located at various locale, considering the limitation of anterior rotation inherited with the risk of vascular compromise, it might be more beneficial to perform posterior rotation osteotomy in taking account of gait cycle.

  20. Development of a New Robotic Ankle Rehabilitation Platform for Hemiplegic Patients after Stroke

    PubMed Central

    Duan, Lihong

    2018-01-01

    A large amount of hemiplegic survivors are suffering from motor impairment. Ankle rehabilitation exercises act an important role in recovering patients' walking ability after stroke. Currently, patients mainly perform ankle exercise to reobtain range of motion (ROM) and strength of the ankle joint under a therapist's assistance by manual operation. However, therapists suffer from high work intensity, and most of the existed rehabilitation devices focus on ankle functional training and ignore the importance of neurological rehabilitation in the early hemiplegic stage. In this paper, a new robotic ankle rehabilitation platform (RARP) is proposed to assist patients in executing ankle exercise. The robotic platform consists of two three-DOF symmetric layer-stacking mechanisms, which can execute ankle internal/external rotation, dorsiflexion/plantarflexion, and inversion/eversion exercise while the rotation center of the distal zone of the robotic platform always coincides with patients' ankle pivot center. Three exercise modes including constant-speed exercise, constant torque-impedance exercise, and awareness exercise are developed to execute ankle training corresponding to different rehabilitation stages. Experiments corresponding to these three ankle exercise modes are performed, the result demonstrated that the RARP is capable of executing ankle rehabilitation, and the novel awareness exercise mode motivates patients to proactively participate in ankle training. PMID:29736231

  1. Hip Rotation Range of Motion in People With and Without Low Back Pain Who Participate in Rotation-Related Sports

    PubMed Central

    Van Dillen, Linda R.; Bloom, Nancy J.; Gombatto, Sara P.; Susco, Thomas M.

    2008-01-01

    Objective To examine whether passive hip rotation motion was different between people with and without low back pain (LBP) who regularly participate in sports that require repeated rotation of the trunk and hips. We hypothesized that people with LBP would have less total hip rotation motion and more asymmetry of motion between sides than people without LBP. Design Two group, case-control. Setting University-based musculoskeletal analysis laboratory. Participants Forty-eight subjects (35 males, 13 females; mean age: 26.56±7.44 years) who reported regular participation in a rotation-related sport participated. Two groups were compared; people with LBP (N=24) and people without LBP (N=24; NoLBP). Main outcome measures Data were collected on participant-related, LBP-related, sport-related and activity-related variables. Measures of passive hip rotation range of motion were obtained. The differences between the LBP and NoLBP groups were examined. Results People with and without a history of LBP were the same with regard to all participant-related, sport-related and activity-related variables. The LBP group had significantly less total rotation (P=.035) and more asymmetry of total rotation, right hip versus left hip, (P=.022) than the NoLBP group. Left total hip rotation was more limited than right total hip rotation in the LBP group (P=.004). There were no significant differences in left and right total hip rotation for the NoLBP group (P=.323). Conclusions Among people who participate in rotation-related sports, those with LBP had less overall passive hip rotation motion and more asymmetry of rotation between sides than people without LBP. These findings suggest that the specific directional demands imposed on the hip and trunk during regularly performed activities may be an important consideration in deciding which impairments may be most relevant to test and to consider in prevention and intervention strategies. PMID:19081817

  2. Note: Sub-Kelvin refrigeration with dry-coolers on a rotating system.

    PubMed

    Oguri, S; Ishitsuka, H; Choi, J; Kawai, M; Tajima, O

    2014-08-01

    We developed a cryogenic system on a rotating table that achieves sub-Kelvin conditions. The cryogenic system consists of a helium sorption cooler and a pulse tube cooler in a cryostat mounted on a rotating table. Two rotary-joint connectors for electricity and helium gas circulation enable the coolers to be operated and maintained with ease. We performed cool-down tests under a condition of continuous rotation at 20 rpm. We obtained a temperature of 0.23 K with a holding time of more than 24 h, thus complying with catalog specifications. We monitored the system's performance for four weeks; two weeks with and without rotation. A few-percent difference in conditions was observed between these two states. Most applications can tolerate such a slight difference. The technology developed is useful for various scientific applications requiring sub-Kelvin conditions on rotating platforms.

  3. Analysis of 3D Scan Measurement Distribution with Application to a Multi-Beam Lidar on a Rotating Platform.

    PubMed

    Morales, Jesús; Plaza-Leiva, Victoria; Mandow, Anthony; Gomez-Ruiz, Jose Antonio; Serón, Javier; García-Cerezo, Alfonso

    2018-01-30

    Multi-beam lidar (MBL) rangefinders are becoming increasingly compact, light, and accessible 3D sensors, but they offer limited vertical resolution and field of view. The addition of a degree-of-freedom to build a rotating multi-beam lidar (RMBL) has the potential to become a common solution for affordable rapid full-3D high resolution scans. However, the overlapping of multiple-beams caused by rotation yields scanning patterns that are more complex than in rotating single beam lidar (RSBL). In this paper, we propose a simulation-based methodology to analyze 3D scanning patterns which is applied to investigate the scan measurement distribution produced by the RMBL configuration. With this purpose, novel contributions include: (i) the adaption of a recent spherical reformulation of Ripley's K function to assess 3D sensor data distribution on a hollow sphere simulation; (ii) a comparison, both qualitative and quantitative, between scan patterns produced by an ideal RMBL based on a Velodyne VLP-16 (Puck) and those of other 3D scan alternatives (i.e., rotating 2D lidar and MBL); and (iii) a new RMBL implementation consisting of a portable tilting platform for VLP-16 scanners, which is presented as a case study for measurement distribution analysis as well as for the discussion of actual scans from representative environments. Results indicate that despite the particular sampling patterns given by a RMBL, its homogeneity even improves that of an equivalent RSBL.

  4. Analysis of 3D Scan Measurement Distribution with Application to a Multi-Beam Lidar on a Rotating Platform

    PubMed Central

    Plaza-Leiva, Victoria; Serón, Javier

    2018-01-01

    Multi-beam lidar (MBL) rangefinders are becoming increasingly compact, light, and accessible 3D sensors, but they offer limited vertical resolution and field of view. The addition of a degree-of-freedom to build a rotating multi-beam lidar (RMBL) has the potential to become a common solution for affordable rapid full-3D high resolution scans. However, the overlapping of multiple-beams caused by rotation yields scanning patterns that are more complex than in rotating single beam lidar (RSBL). In this paper, we propose a simulation-based methodology to analyze 3D scanning patterns which is applied to investigate the scan measurement distribution produced by the RMBL configuration. With this purpose, novel contributions include: (i) the adaption of a recent spherical reformulation of Ripley’s K function to assess 3D sensor data distribution on a hollow sphere simulation; (ii) a comparison, both qualitative and quantitative, between scan patterns produced by an ideal RMBL based on a Velodyne VLP-16 (Puck) and those of other 3D scan alternatives (i.e., rotating 2D lidar and MBL); and (iii) a new RMBL implementation consisting of a portable tilting platform for VLP-16 scanners, which is presented as a case study for measurement distribution analysis as well as for the discussion of actual scans from representative environments. Results indicate that despite the particular sampling patterns given by a RMBL, its homogeneity even improves that of an equivalent RSBL. PMID:29385705

  5. Dynamics of flow control in an emulated boundary layer-ingesting offset diffuser

    NASA Astrophysics Data System (ADS)

    Gissen, A. N.; Vukasinovic, B.; Glezer, A.

    2014-08-01

    Dynamics of flow control comprised of arrays of active (synthetic jets) and passive (vanes) control elements , and its effectiveness for suppression of total-pressure distortion is investigated experimentally in an offset diffuser, in the absence of internal flow separation. The experiments are conducted in a wind tunnel inlet model at speeds up to M = 0.55 using approach flow conditioning that mimics boundary layer ingestion on a Blended-Wing-Body platform. Time-dependent distortion of the dynamic total-pressure field at the `engine face' is measured using an array of forty total-pressure probes, and the control-induced distortion changes are analyzed using triple decomposition and proper orthogonal decomposition (POD). These data indicate that an array of the flow control small-scale synthetic jet vortices merge into two large-scale, counter-rotating streamwise vortices that exert significant changes in the flow distortion. The two most energetic POD modes appear to govern the distortion dynamics in either active or hybrid flow control approaches. Finally, it is shown that the present control approach is sufficiently robust to reduce distortion with different inlet conditions of the baseline flow.

  6. Improved assessment of accuracy and performance using a rotational paper-based device for multiplexed detection of heavy metals.

    PubMed

    Sun, Xiange; Li, Bowei; Qi, Anjin; Tian, Chongguo; Han, Jinglong; Shi, Yajun; Lin, Bingcheng; Chen, Lingxin

    2018-02-01

    In this work, a novel rotational microfluidic paper-based device was developed to improve the accuracy and performance of the multiplexed colorimetric detection by effectively avoiding the diffusion of colorimetric reagent on the detection zone. The integrated paper-based rotational valves were used to control the connection or disconnection between detection zones and fluid channels. Based on the manipulation of the rotational valves, this rotational paper-based device could prevent the random diffusion of colorimetric reagent and reduce the error of quantitative analysis considerably. The multiplexed colorimetric detection of heavy metals Ni(II), Cu(II) and Cr(VI) were implemented on the rotational device and the detection limits could be found to be 4.8, 1.6, and 0.18mg/L, respectively. The developed rotational device showed the great advantage in improving the detection accuracy and was expected to be a low-cost, portable analytical platform for the on-site detection. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Sample holder for X-ray diffractometry

    DOEpatents

    Hesch, Victor L.

    1992-01-01

    A sample holder for use with X-ray diffractometers with the capability to rotate the sample, as well as to adjust the position of the sample in the x, y, and z directions. Adjustment in the x direction is accomplished through loosening set screws, moving a platform, and retightening the set screws. Motion translators are used for adjustment in the y and z directions. An electric motor rotates the sample, and receives power from the diffractometer.

  8. Methods for multi-material stereolithography

    DOEpatents

    Wicker, Ryan [El Paso, TX; Medina, Francisco [El Paso, TX; Elkins, Christopher [Redwood City, CA

    2011-06-14

    Methods and systems of stereolithography for building cost-efficient and time-saving multi-material, multi-functional and multi-colored prototypes, models and devices configured for intermediate washing and curing/drying is disclosed including: laser(s), liquid and/or platform level sensing system(s), controllable optical system(s), moveable platform(s), elevator platform(s), recoating system(s) and at least one polymer retaining receptacle. Multiple polymer retaining receptacles may be arranged in a moveable apparatus, wherein each receptacle is adapted to actively/passively maintain a uniform, desired level of polymer by including a recoating device and a material fill/remove system. The platform is movably accessible to the polymer retaining receptacle(s), elevator mechanism(s) and washing and curing/drying area(s) which may be housed in a shielded enclosure(s). The elevator mechanism is configured to vertically traverse and rotate the platform, thus providing angled building, washing and curing/drying capabilities. A horizontal traversing mechanism may be included to facilitate manufacturing between components of SL cabinet(s) and/or alternative manufacturing technologies.

  9. A gravity exercise system. [for muscle conditioning during manned space flight

    NASA Technical Reports Server (NTRS)

    Brandt, W. E.; Clark, A. L.

    1973-01-01

    An effective method for muscle conditioning during weightlessness flight is derived from isometric exercise. The basic principle of gravity exercise is to periodically displace the human body upon reactionless rollers so that spacial equilibrium can only be maintained by the proper tension and relaxation of the body's muscles. A rotating platform mounted upon two degrees of freedom rollers provides such a condition of gravitational reaction stress throughout each of its 360 deg rotation.

  10. In-line rotating torque sensor with on-board amplifier

    DOEpatents

    Kronberg, James W.

    1990-01-01

    A rotating torque sensor apparatus and method for measuring small torques comprising a shaft, a platform having a circuit board and a first moment arm attached to the shaft, a rotatable wheel coaxial with the shaft and having a second moment arm spaced apart from the first moment arm with a load cell therebetween for generating an electric signal as the torque is applied to the shaft and transferred through the moment arms to the load cell. The electrical signal is conducted from the load cell to the circuit board for filtering and amplification before being extracted from the torque assembly through a slip ring.

  11. Prolonged asymmetric vestibular stimulation induces opposite, long-term effects on self-motion perception and ocular responses.

    PubMed

    Pettorossi, V E; Panichi, R; Botti, F M; Kyriakareli, A; Ferraresi, A; Faralli, M; Schieppati, M; Bronstein, A M

    2013-04-01

    Self-motion perception and the vestibulo-ocular reflex (VOR) were investigated in healthy subjects during asymmetric whole body yaw plane oscillations while standing on a platform in the dark. Platform oscillation consisted of two half-sinusoidal cycles of the same amplitude (40°) but different duration, featuring a fast (FHC) and a slow half-cycle (SHC). Rotation consisted of four or 20 consecutive cycles to probe adaptation further with the longer duration protocol. Self-motion perception was estimated by subjects tracking with a pointer the remembered position of an earth-fixed visual target. VOR was measured by electro-oculography. The asymmetric stimulation pattern consistently induced a progressive increase of asymmetry in motion perception, whereby the gain of the tracking response gradually increased during FHCs and decreased during SHCs. The effect was observed already during the first few cycles and further increased during 20 cycles, leading to a totally distorted location of the initial straight-ahead. In contrast, after some initial interindividual variability, the gain of the slow phase VOR became symmetric, decreasing for FHCs and increasing for SHCs. These oppositely directed adaptive effects in motion perception and VOR persisted for nearly an hour. Control conditions using prolonged but symmetrical stimuli produced no adaptive effects on either motion perception or VOR. These findings show that prolonged asymmetric activation of the vestibular system leads to opposite patterns of adaptation of self-motion perception and VOR. The results provide strong evidence that semicircular canal inputs are processed centrally by independent mechanisms for perception of body motion and eye movement control. These divergent adaptation mechanisms enhance awareness of movement toward the faster body rotation, while improving the eye stabilizing properties of the VOR.

  12. Prolonged asymmetric vestibular stimulation induces opposite, long-term effects on self-motion perception and ocular responses

    PubMed Central

    Pettorossi, V E; Panichi, R; Botti, F M; Kyriakareli, A; Ferraresi, A; Faralli, M; Schieppati, M; Bronstein, A M

    2013-01-01

    Self-motion perception and the vestibulo-ocular reflex (VOR) were investigated in healthy subjects during asymmetric whole body yaw plane oscillations while standing on a platform in the dark. Platform oscillation consisted of two half-sinusoidal cycles of the same amplitude (40°) but different duration, featuring a fast (FHC) and a slow half-cycle (SHC). Rotation consisted of four or 20 consecutive cycles to probe adaptation further with the longer duration protocol. Self-motion perception was estimated by subjects tracking with a pointer the remembered position of an earth-fixed visual target. VOR was measured by electro-oculography. The asymmetric stimulation pattern consistently induced a progressive increase of asymmetry in motion perception, whereby the gain of the tracking response gradually increased during FHCs and decreased during SHCs. The effect was observed already during the first few cycles and further increased during 20 cycles, leading to a totally distorted location of the initial straight-ahead. In contrast, after some initial interindividual variability, the gain of the slow phase VOR became symmetric, decreasing for FHCs and increasing for SHCs. These oppositely directed adaptive effects in motion perception and VOR persisted for nearly an hour. Control conditions using prolonged but symmetrical stimuli produced no adaptive effects on either motion perception or VOR. These findings show that prolonged asymmetric activation of the vestibular system leads to opposite patterns of adaptation of self-motion perception and VOR. The results provide strong evidence that semicircular canal inputs are processed centrally by independent mechanisms for perception of body motion and eye movement control. These divergent adaptation mechanisms enhance awareness of movement toward the faster body rotation, while improving the eye stabilizing properties of the VOR. PMID:23318876

  13. Identification of Mobile Phones Using the Built-In Magnetometers Stimulated by Motion Patterns.

    PubMed

    Baldini, Gianmarco; Dimc, Franc; Kamnik, Roman; Steri, Gary; Giuliani, Raimondo; Gentile, Claudio

    2017-04-06

    We investigate the identification of mobile phones through their built-in magnetometers. These electronic components have started to be widely deployed in mass market phones in recent years, and they can be exploited to uniquely identify mobile phones due their physical differences, which appear in the digital output generated by them. This is similar to approaches reported in the literature for other components of the mobile phone, including the digital camera, the microphones or their RF transmission components. In this paper, the identification is performed through an inexpensive device made up of a platform that rotates the mobile phone under test and a fixed magnet positioned on the edge of the rotating platform. When the mobile phone passes in front of the fixed magnet, the built-in magnetometer is stimulated, and its digital output is recorded and analyzed. For each mobile phone, the experiment is repeated over six different days to ensure consistency in the results. A total of 10 phones of different brands and models or of the same model were used in our experiment. The digital output from the magnetometers is synchronized and correlated, and statistical features are extracted to generate a fingerprint of the built-in magnetometer and, consequently, of the mobile phone. A SVM machine learning algorithm is used to classify the mobile phones on the basis of the extracted statistical features. Our results show that inter-model classification (i.e., different models and brands classification) is possible with great accuracy, but intra-model (i.e., phones with different serial numbers and same model) classification is more challenging, the resulting accuracy being just slightly above random choice.

  14. Identification of Mobile Phones Using the Built-In Magnetometers Stimulated by Motion Patterns

    PubMed Central

    Baldini, Gianmarco; Dimc, Franc; Kamnik, Roman; Steri, Gary; Giuliani, Raimondo; Gentile, Claudio

    2017-01-01

    We investigate the identification of mobile phones through their built-in magnetometers. These electronic components have started to be widely deployed in mass market phones in recent years, and they can be exploited to uniquely identify mobile phones due their physical differences, which appear in the digital output generated by them. This is similar to approaches reported in the literature for other components of the mobile phone, including the digital camera, the microphones or their RF transmission components. In this paper, the identification is performed through an inexpensive device made up of a platform that rotates the mobile phone under test and a fixed magnet positioned on the edge of the rotating platform. When the mobile phone passes in front of the fixed magnet, the built-in magnetometer is stimulated, and its digital output is recorded and analyzed. For each mobile phone, the experiment is repeated over six different days to ensure consistency in the results. A total of 10 phones of different brands and models or of the same model were used in our experiment. The digital output from the magnetometers is synchronized and correlated, and statistical features are extracted to generate a fingerprint of the built-in magnetometer and, consequently, of the mobile phone. A SVM machine learning algorithm is used to classify the mobile phones on the basis of the extracted statistical features. Our results show that inter-model classification (i.e., different models and brands classification) is possible with great accuracy, but intra-model (i.e., phones with different serial numbers and same model) classification is more challenging, the resulting accuracy being just slightly above random choice. PMID:28383482

  15. Interchange rotation factors and player characteristics influence physical and technical performance in professional Australian Rules football.

    PubMed

    Dillon, Patrick A; Kempton, Thomas; Ryan, Samuel; Hocking, Joel; Coutts, Aaron J

    2018-03-01

    To examine the effects of match-related and individual player characteristics on activity profile and technical performance during rotations in professional Australian football. Longitudinal observational study. Global positioning system data and player rating scores were collected from 33 professional Australian football players during 15 Australian football League matches. Player rating scores were time aligned with their relative total and high-speed running (HSR) distance (>20kmh -1 ) for each on ground rotation. Individual players' maximal aerobic running speed (MAS) was determined from a two-kilometre trial. A multilevel linear mixed model was used to examine the influence of rotations on physical activity profiles and skill execution during match play. Rotation duration and accumulated distance resulted in a trivial-to-moderate reduction in relative total and HSR distances as well as relative rating points. The number of disposals in a rotation had a small positive effect on relative total and HSR distances and a large positive effect on relative rating points. MAS was associated with a moderate-to-large increase in relative total distance, but had a large negative effect on relative rating points. Previous rotation time, stoppages and the number of rotations in the quarter had a trivial-to-small negative effect on relative total and HSR distances. A greater speed (mmin -1 ) was associated with a trivial increase in rating points during a rotation, while there was a trivial decrease in relative total distance as rating points increased. The complex relationship between factors that influence activity profile and technical performance during rotations in Australian football needs to be considered when interpreting match performance. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. Deck the Halls. Animated Displays III: Mechanical Puzzles.

    ERIC Educational Resources Information Center

    Pizzo, Joe, Ed.

    1993-01-01

    Describes an exhibit containing four basic demonstrations relating to center of gravity and rotational equilibrium. The demonstrations involve (1) the stack of bricks, (2) the double cone, (3) the spool roller, and (4) the platform balance. (MDH)

  17. Fiber Bragg grating ring resonators under rotation for angular velocity sensing.

    PubMed

    Campanella, C E; De Leonardis, F; Passaro, V M N

    2015-05-20

    In this paper we investigate the possibility of using hybrid resonators based on fiber Bragg grating ring resonators (FBGRRs) and π-shifted FBGRRs (i.e., defective FBGRRs) as rotation sensitive elements for gyroscope applications. In particular, we model the conventional fiber Bragg grating (FBG) with the coupled mode theory by taking into account how the Sagnac effect, induced by the rotation, modifies the eigenvalues, the photonic band gap, and the spectral response of the FBG. Then, on the basis of the FBG model under rotation conditions, the spectral responses of the FBGRR and π-FBGRR have been evaluated, confirming that the Sagnac effect manifests itself with a spectral shift of the eigensolutions. This physical investigation can be exploited for opening new ways in the optical gyroscope platforms.

  18. Mechanical features of the shuttle rotating service structure

    NASA Technical Reports Server (NTRS)

    Crump, J. M.

    1985-01-01

    With the development of the space shuttle launching facilities, it became mandatory to develop a shuttle rotating service structure to provide for the insertion and/or removal of payloads at the launch pads. The rotating service structure is a welded tubular steel space frame 189 feet high, 65 feet wide, and weighing 2100 tons. At the pivot column the structure is supported on a 30 inch diameter hemispherical bearing. At the opposite terminus the structure is supported on two truck assemblies each having eight 36 inch diameter double flanged wheels. The following features of the rotating service structure are discussed: (1) thermal expansion and contraction; (2) hurricane tie downs; (3) payload changeout room; (4) payload ground handling mechanism; (5) payload and orbiter access platforms; and (6) orbiter cargo bay access.

  19. Simulating the dynamic behavior of a vertical axis wind turbine operating in unsteady conditions

    NASA Astrophysics Data System (ADS)

    Battisti, L.; Benini, E.; Brighenti, A.; Soraperra, G.; Raciti Castelli, M.

    2016-09-01

    The present work aims at assessing the reliability of a simulation tool capable of computing the unsteady rotational motion and the associated tower oscillations of a variable speed VAWT immersed in a coherent turbulent wind. As a matter of fact, since the dynamic behaviour of a variable speed turbine strongly depends on unsteady wind conditions (wind gusts), a steady state approach can't accurately catch transient correlated issues. The simulation platform proposed here is implemented using a lumped mass approach: the drive train is described by resorting to both the polar inertia and the angular position of rotating parts, also considering their speed and acceleration, while rotor aerodynamic is based on steady experimental curves. The ultimate objective of the presented numerical platform is the simulation of transient phenomena, driven by turbulence, occurring during rotor operation, with the aim of supporting the implementation of efficient and robust control algorithms.

  20. Realization of LOS (Line of Sight) stabilization based on reflector using carrier attitude compensation method

    NASA Astrophysics Data System (ADS)

    Mao, Yao; Tian, Jing; Ma, Jia-guang

    2015-02-01

    The techonology of LOS stabilization is widely applicated in moving carrier photoelectric systems such as shipborne, airborne and so on. In application situations with compact structure, such as LOS stabilization system of unmanned aerial vehicle, LOS stabilization based on reflector is adopted, and the detector is installed on the carrier to reduce the volume of stabilized platform and loading weight. However, the LOS deflection angle through reflector and the rotation angle of the reflector has a ratio relation of 2:1, simple reflector of stable inertial space can not make the optical axis stable. To eliminate the limitation of mirror stabilizing method, this article puts forward the carrier attitude compensation method, which uses the inertial sensor installed on the carrier to measure the attitude change of the carrier, and the stabilized platform rotating half of the carrier turbulence angle to realize the LOS stabilization.

  1. Metasurface Freeform Nanophotonics.

    PubMed

    Zhan, Alan; Colburn, Shane; Dodson, Christopher M; Majumdar, Arka

    2017-05-10

    Freeform optics aims to expand the toolkit of optical elements by allowing for more complex phase geometries beyond rotational symmetry. Complex, asymmetric curvatures are employed to enhance the performance of optical components while minimizing their size. Unfortunately, these high curvatures and complex forms are often difficult to manufacture with current technologies, especially at the micron scale. Metasurfaces are planar sub-wavelength structures that can control the phase, amplitude, and polarization of incident light, and can thereby mimic complex geometric curvatures on a flat, wavelength-scale thick surface. We present a methodology for designing analogues of freeform optics using a silicon nitride based metasurface platform for operation at visible wavelengths. We demonstrate a cubic phase plate with a point spread function exhibiting enhanced depth of field over 300 micron along the optical axis with potential for performing metasurface-based white light imaging, and an Alvarez lens with a tunable focal length range of over 2.5 mm corresponding to a change in optical power of ~1600 diopters with 100 micron of total mechanical displacement. The adaptation of freeform optics to a sub-wavelength metasurface platform allows for further miniaturization of optical components and offers a scalable route toward implementing near-arbitrary geometric curvatures in nanophotonics.

  2. Orbital construction demonstration study. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A conceptual design and program plan for an Orbital Construction Demonstration Article (OCDA), that can be used for technology growth and verification, and as the construction facility for a variety of large structures is presented. The OCDA design includes a large work platform, a rotating manipulator boom, a 250 kw solar array, and a core module of subsystems with a total mass of 37,093 kg, that can be assembled in three shuttle flights. An analysis of OCDA continued utility potential indicates that a shuttle tended platform with 250 kW of power can effectively be used to construct highly beneficial antenna systems and large demonstration articles that advance solar power satellite technologies. The construction of 100 m parabolic reflectors for use as a radiometer for measuring soil moisture and water salinity was found to be within the capabilities of OCDA concept. With 252 fixed beams for high population centers, and 16 scanning beams for rural areas, the antenna has the potential to significantly improve U.S. space based communications systems. The OCDA, that is slightly increased in size, was found adequate to build a large 2 MW solar array which, when coupled to a transmit antenna, demonstrate power transfer from space to ground.

  3. Annual Report 1984.

    DTIC Science & Technology

    1985-01-01

    equipped with data collection platforms (DCP) by the end of FY 1985. (b) Communication. The DCP’s transmit the remote gaging station data over the...activated 78 platforms in FY 84 bringing the total number of operating stations to 85. Plans are to activate seven more platforms in FY 85. c. Acoustic... Platforms . The total program cost for FY 1984 is shown in Table VI-3. The total program cost for FY 1985 will be $172,720. (2) National Weather Service

  4. Protonmotive force: development of electrostatic drivers for synthetic molecular motors.

    PubMed

    Crowley, James D; Steele, Ian M; Bosnich, Brice

    2006-12-04

    Ferrocene has been investigated as a platform for developing protonmotive electrostatic drivers for molecular motors. When two 3-pyridine groups are substituted to the (rapidly rotating) cyclopentadienyl (Cp) rings of ferrocene, one on each Cp, it is shown that the (Cp) eclipsed, pi-stacked rotameric conformation is preferred both in solution and in the solid state. Upon quaternization of both of the pyridines substituents, either by protonation or by alkylation, it is shown that the preferred rotameric conformation is one where the pyridinium groups are rotated away from the fully pi-stacked conformation. Electrostatic calculations indicate that the rotation is caused by the electrostatic repulsion between the charges. Consistently, when the pi-stacking energy is increased pi-stacked population increases, and conversely when the electrostatic repulsion is increased pi-stacked population is decreased. This work serves to provide an approximate estimate of the amount of torque that the electrostatically driven ferrocene platform can generate when incorporated into a molecular motor. The overall conclusion is that the electrostatic interaction energy between dicationic ferrocene dipyridyl systems is similar to the pi-stacking interaction energy and, consequently, at least tricationic systems are required to fully uncouple the pi-stacked pyridine substituents.

  5. A lab-in-a-droplet bioassay strategy for centrifugal microfluidics with density difference pumping, power to disc and bidirectional flow control.

    PubMed

    Wang, Guanghui; Ho, Ho-Pui; Chen, Qiulan; Yang, Alice Kar-Lai; Kwok, Ho-Chin; Wu, Shu-Yuen; Kong, Siu-Kai; Kwan, Yiu-Wa; Zhang, Xuping

    2013-09-21

    In this paper, we present a lab-in-a-droplet bioassay strategy for a centrifugal microfluidics or lab-on-a-disc (LOAD) platform with three important advancements including density difference pumping, power to disc and bidirectional flow control. First, with the water based bioassay droplets trapped in a micro-channel filled with mineral oil, centrifugal force due to the density difference between the water and oil phases actuates droplet movement while the oil based medium remains stationary. Second, electricity is coupled to the rotating disc through a split-core transformer, thus enabling on-chip real-time heating in selected areas as desired and wireless programmable functionality. Third, an inertial mechanical structure is proposed to achieve bidirectional flow control within the spinning disc. The droplets can move back and forth between two heaters upon changing the rotational speed. Our platform is an essential and versatile solution for bioassays such as those involving DNA amplification, where localized temperature cycling is required. Finally, without the loss of generality, we demonstrate the functionality of our platform by performing real-time polymerase chain reaction (RT-PCR) in a linear microchannel made with PTFE (Teflon) micro-tubing.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dewyngaert, K; Jozsef, G; Formenti, S

    Purpose: To report on the clinical validation of the Varian Pivotal™ Treatment Solution for Prone Breast Care: a platform for prone breast radiation therapy. Methods: Patients treated using Breast Conserving Radiation Therapy may benefit from treatment in the prone position with the breast tissue falling freely away from the body. This geometry allows the breast tissue to be treated while avoiding the lung and heart tissue. Eighteen patients simulated and treated using the Varian Medical Systems Pivotal™ Treatment Solution for Prone Breast Care were monitored over the course of treatment for positioning integrity and reproducibility. As this carbon-fiber platform actuallymore » replaces a portion of the couch top, indexing is inherent to its design. Patients were positioned on the couch and aligned using fiducial markers and lateral SSD to the breast fiducial point. The daily couch coordinates then serves as indicators for positioning variability with this system. Results: The variations in couch vertical, longitudinal and lateral positions were centered on a mean value of zero with standard deviations of 0.44cm, 0.75cm and 0.79cm respectively. Other factors explored were variations in distance of mid-sternum to table edge and patient rotation into the opening. The median rotation of the chest wall was found to be 11.5 degrees at CT-Simulation with a median distance of 2.5cm from midsternum to support opening. Patient rotation was not associated with either breast size or distance from edge of platform. Conclusion: The Pivotal™ Treatment solution consists of a couch top that replaces the standard top and as such is open from beneath without obstruction. This is a distinction from all other solutions which rely on a platform positioned above and indexed to the treatment couch. We found the reproducibility to be consistent with our historical measures while offering benefits of an integrated solution as stated above. supported by Professional Services Agreeement with Varian Medical Systems.« less

  7. Artificial gravity considerations for a mars exploration mission

    NASA Technical Reports Server (NTRS)

    Young, L. R.

    1999-01-01

    Artificial gravity (AG), as a means of preventing physiological deconditioning of astronauts during long-duration space flights, presents certain special challenges to the otolith organs and the adaptive capabilities of the CNS. The key issues regarding the choice of AG acceleration, radius, and rotation rate are reviewed from the viewpoints of physiological requirements and human factors disturbances. Head movements and resultant Coriolis forces on the rotating platform may limit the usefulness of economical short centrifuges for other than brief periods of intermittent stimulation.

  8. Modular design attitude control system

    NASA Technical Reports Server (NTRS)

    Chichester, F. D.

    1982-01-01

    A hybrid multilevel linear quadratic regulator (ML-LQR) approach was developed and applied to the attitude control of models of the rotational dynamics of a prototype flexible spacecraft and of a typical space platform. Three axis rigid body flexible suspension models were developed for both the spacecraft and the space platform utilizing augmented body methods. Models of the spacecraft with hybrid ML-LQR attitude control and with LQR attitude control were simulated and their response with the two different types of control were compared.

  9. Preliminary Airworthiness Evaluation OH-58C Helicopter Configured with a Mast Mounted Sight

    DTIC Science & Technology

    1980-05-01

    r’assemnbled on tlhc bench and measured for component allirnment. It was found tlait the nonrotating platform had a 0.026 inch radial runout and a 0(020 face... runout with respect to the mast axis of rotation. The contractor determined that this runout was sufficient to cause a I,’rev vibration at the MMS cc...mast to nonrotating platform allignment. By selectively matching the above components, the final configuration resulted in a face runout of 0.002

  10. Technology Assessment for External Implementation of Artificial Gravity Utilizing the Deep Space Gateway Platform

    NASA Astrophysics Data System (ADS)

    Raychev, R.; Griko, Y. V.

    2018-02-01

    Scenario drafting for early technology assessment of the external space centrifuge with little mass and variable radius of rotation is proposed to counteract micro gravity-associated physiological alterations in all physiological systems.

  11. Rotational glenohumeral adaptations are associated with shoulder pathology in professional male handball players.

    PubMed

    Lubiatowski, Przemyslaw; Kaczmarek, Piotr; Cisowski, Pawel; Breborowicz, Ewa; Grygorowicz, Monika; Dzianach, Marcin; Krupecki, Tomasz; Laver, Lior; Romanowski, Leszek

    2018-01-01

    Glenohumeral range of motion adaptations may affect throwing athletes and contribute to shoulder injury. The purpose of this study was to evaluate shoulder rotation deficits among elite professional handball players and its correlation to the presence of shoulder pain and morphological changes. Eighty-seven elite professional handball players and 41 healthy non-athlete volunteers participated in the study. Evaluations included measurement of range of internal and external rotation, total arch of motion, identification of shoulder pain and ultrasound scan for diagnosis of rotator cuff tears and internal impingement. Glenohumeral rotational deficits (>20-25°) were found among 11 players group (13%). The throwing shoulders in the players group showed a decrease in internal rotation and an increase in external rotation with significantly larger ranges among players compared to the non-athlete group. Internal rotation deficit >20° was associated with higher incidence of shoulder pain among players. Both internal rotation deficits (>25°) and total arch of motion deficit (>20°) co-existed with higher incidence of internal impingement. Shoulder pain was common (36/97-41%) and was associated with decreased external rotation and total arch of motion. Internal impingement (found in 13/87-15%) correlated with decreased rotation ranges and a greater deficit in total arch of motion, whereas higher gain in external rotation correlated with a partial rotator cuff tear (found in 12/87-14%). Shoulder pathologies and problems commonly affected the group of handball players. Greater glenohumeral rotational deficits in throwing shoulders of handball players correlate with shoulder pain and internal impingement, while increased external rotation with partial rotator cuff tears. Such deficits affect 13% of the athlete population. Major clinical relevance of the study is to monitor handball players' shoulders both clinically and by proper imaging. Evaluation of range of rotation seems to identify shoulders at risk of the pathology. Cross-Sectional study with control group, Level II.

  12. The behavior of bouncing disks and pizza tossing

    NASA Astrophysics Data System (ADS)

    Liu, K.-C.; Friend, J.; Yeo, L.

    2009-03-01

    We investigate the dynamics of a disk bouncing on a vibrating platform - a variation of the classic bouncing ball problem - that captures the physics of pizza tossing and the operation of certain standing-wave ultrasonic motors (SWUMs). The system's dynamics explains why certain tossing motions are used by dough-toss performers for different tricks: a helical trajectory is used in single tosses because it maximizes energy efficiency and the dough's airborne rotational speed, a semi-elliptical motion is used in multiple tosses because it is easier for maintaining dough rotation at the maximum rotational speed. The system's bifurcation diagram and basins of attraction also informs SWUM designers about the optimal design for high speed and minimal sensitivity to perturbation.

  13. Six-degree-of-freedom multi-axes positioning apparatus

    DOEpatents

    Bieg, L.F.X.

    1999-05-11

    A six-degree-of-freedom multi-axes positioning apparatus is comprised of a geometry of six independent angle connectors. Each angle connector connects two fixed length rods to a pivot on one of two opposing platforms. The combination of an angle connector, at least two pivots and at least two rods having free ends connected to the pivots comprises a leg assembly. The spatial location of the upper platform is changed in relation to the lower platform by angular changes within each angle connector. This angular change results in degrees of motion within the apparatus defined as X, Y, Z, Tip, Tilt, and Rotation, or a combination of the above. This invention is known as a ROTOPOD. 9 figs.

  14. Six-degree-of-freedom multi-axes positioning apparatus

    DOEpatents

    Bieg, Lothar F. X.

    1999-01-01

    A six-degree-of-freedom multi-axes positioning apparatus is comprised of a geometry of six independent angle connectors. Each angle connector connects two fixed length rods to a pivot on one of two opposing platforms. The combination of an angle connector, at least two pivots and at least two rods having free ends connected to the pivots comprises a leg assembly. The spatial location of the upper platform is changed in relation to the lower platform by angular changes within each angle connector. This angular change results in degrees of motion within the apparatus defined as X, Y, Z, Tip, Tilt, and Rotation, or a combination of the above. This invention is known as a ROTOPOD.

  15. Response of semicircular canal dependent units in vestibular nuclei to rotation of a linear acceleration vector without angular acceleration

    PubMed Central

    Benson, A. J.; Guedry, F. E.; Jones, G. Melvill

    1970-01-01

    1. Recent experiments have shown that rotation of a linear acceleration vector round the head can generate involuntary ocular nystagmus in the absence of angular acceleration. The present experiments examine the suggestion that adequate stimulation of the semicircular canals may contribute to this response. 2. Decerebrate cats were located in a stereotaxic device on a platform, slung from four parallel cables, which could be driven smoothly round a circular orbit without inducing significant angular movement of the platform. This Parallel Swing Rotation (PSR) generated a centripetal acceleration of 4·4 m/sec2 which rotated round the head at 0·52 rev/sec. 3. The discharge frequency of specifically lateral canal-dependent neural units in the vestibular nuclei of cats was recorded during PSR to right and left, and in the absence of motion. The dynamic responses to purely angular motion were also examined on a servo-driven turntable. 4. Without exception all proven canal-dependent cells examined (twenty-nine cells in nine cats) were more active during PSR in the direction of endolymph circulation assessed to be excitatory to the unit, than during PSR in the opposite direction. 5. The observed changes in discharge frequency are assessed to have been of a magnitude appropriate for the generation of the involuntary oculomotor response induced by the same stimulus in the intact animal. 6. The findings suggest that a linear acceleration vector which rotates in the plane of the lateral semicircular canals can be an adequate stimulus to ampullary receptors, though an explanation which invokes the modulation of canal cells by a signal dependent upon the sequential activation of macular receptors cannot be positively excluded. PMID:5501270

  16. HELIRADAR technology for helicopter all-weather operations

    NASA Astrophysics Data System (ADS)

    Kreitmair-Steck, Wolfgang; Braun, Guenter

    1997-06-01

    Currently available radar instruments are not capable of guiding a helicopter pilot safely during approach and landing under poor visibility conditions. This is due to lack of resolution and lack of elevation information. The RADAR technology that promises to improve this situation is called ROSAR, which stands for Synthetic Aperture Radar based on ROtating Antennas. In 1992 Eurocopter and Daimler- Benz Aerospace investigated the feasibility of an imaging radar based on ROSAR technology. The objective was to provide a video-like image with a resolution good enough to safely guide a helicopter pilot under poor visibility conditions. ROSAR proved to be especially well suited for this type of application since it allows for a stationary carrier platform: Rotating arms with antennas integrated into their tips can be mounted on top of the rotor head. In this way the scanning region of the antennas can cover 360 degree(s). While rotating, the antenna scans the environment from various visual angles without assuming a movement of the carrier platform itself. The signal is then processed as a function of the rotation angle of the antenna movement along a circular path. A radar system of this type is now under development at Eurocopter and Daimler-Benz Aerospace: HeliRadar. HeliRadar is designed as a frequency modulated continuous wave radar working in a frequency band around 35 GHz. The complete transmitter/receiver system is fixed mounted on top of the rotating axis of the helicopter. The received signals are transferred through the center of the rotor axis down into the cabin of the helicopter, where they are processed in a high performance digital signal processor (processing power: 10 GFLOPS). First encouraging results have been obtained from an experiment with `slow motion' movement of the antenna arm.

  17. Long-lasting effects of neck muscle vibration and contraction on self-motion perception of vestibular origin.

    PubMed

    Pettorossi, Vito Enrico; Panichi, Roberto; Botti, Fabio Massimo; Biscarini, Andrea; Filippi, Guido Maria; Schieppati, Marco

    2015-10-01

    To show that neck proprioceptive input can induce long-term effects on vestibular-dependent self-motion perception. Motion perception was assessed by measuring the subject's error in tracking in the dark the remembered position of a fixed target during whole-body yaw asymmetric rotation of a supporting platform, consisting in a fast rightward half-cycle and a slow leftward half-cycle returning the subject to the initial position. Neck muscles were relaxed or voluntarily contracted, and/or vibrated. Whole-body rotation was administered during or at various intervals after the vibration train. The tracking position error (TPE) at the end of the platform rotation was measured during and after the muscle conditioning maneuvers. Neck input produced immediate and sustained changes in the vestibular perceptual response to whole-body rotation. Vibration of the left sterno-cleido-mastoideus (SCM) or right splenius capitis (SC) or isometric neck muscle effort to rotate the head to the right enhanced the TPE by decreasing the perception of the slow rotation. The reverse effect was observed by activating the contralateral muscle. The effects persisted after the end of SCM conditioning, and slowly vanished within several hours, as tested by late asymmetric rotations. The aftereffect increased in amplitude and persistence by extending the duration of the vibration train (from 1 to 10min), augmenting the vibration frequency (from 5 to 100Hz) or contracting the vibrated muscle. Symmetric yaw rotation elicited a negligible TPE, upon which neck muscle vibrations were ineffective. Neck proprioceptive input induces enduring changes in vestibular-dependent self-motion perception, conditional on the vestibular stimulus feature, and on the side and the characteristics of vibration and status of vibrated muscles. This shows that our perception of whole-body yaw-rotation is not only dependent on accurate vestibular information, but is modulated by proprioceptive information related to previously experienced position of head with respect to trunk. Tonic proprioceptive inflow, as might occur as a consequence of enduring or permanent head postures, can induce adaptive plastic changes in vestibular-dependent motion sensitiveness. These changes might be counteracted by vibration of selected neck muscles. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  18. Different intraoperative kinematics with comparable clinical outcomes of ultracongruent and posterior stabilized mobile-bearing total knee arthroplasty.

    PubMed

    Kim, Tae Woo; Lee, Sang Min; Seong, Sang Cheol; Lee, Sahnghoon; Jang, Jak; Lee, Myung Chul

    2016-09-01

    There remains no consensus as to whether mobile total knee arthroplasty (TKA) should use a posterior cruciate ligament-sacrificing ultracongruent (UC) or a posterior cruciate ligament-substituting posterior stabilized (PS) prosthesis. The purpose of this study was to assess intraoperative kinematics and clinical outcomes of UC and PS rotating platform mobile-bearing TKA. In this randomized controlled study, mobile UC TKA prostheses (n = 45) were compared with mobile PS TKA prostheses (n = 45) with regard to intraoperative kinematics and clinical outcomes. The passive kinematic study using intraoperative navigation system included anterior/posterior translation, varus/valgus alignment and rotation of femur during flexion. The patients were clinically and radiographically evaluated over a 3-year follow-up. Paradoxical anterior translation of the femur was 10.8 ± 5.2 mm in the UC knee from 0° to 82° of knee flexion and 8.7 ± 3.0 mm in the PS knee from 0° to 70° of knee flexion (p = 0.027). Paradoxical internal rotation of the femur was 5.8° in the UC knees and 9.9° in the PS knees (p = 0.003). But, there was no significant difference between the groups in regard to the coronal alignment. There was no significant difference in the range of motion, KS knee scores, KS function scores, and WOMAC index scores. Despite different intraoperative kinematics between mobile UC and mobile PS TKA, neither design reproduced physiologic knee kinematics and there was no difference in clinical outcomes between the two groups. The clinical relevance of the study is that despite different intraoperative kinematics, UC design can be a considerable alternative to PS design in mobile-bearing TKA in respect of clinical outcomes. II.

  19. Paleomagnetic results from Northeast Anatolia: remagnetization in Late Cretaceous sandstones and tectonic rotation at the Eastern extension of the Izmir-Ankara-Erzincan suture zone

    NASA Astrophysics Data System (ADS)

    Cengiz Çinku, Mualla

    2017-12-01

    Paleomagnetic results obtained from Upper Cretaceous sandstones in Northeastern Anatolia demonstrate that the entire area from Erzincan to Kars has been remagnetised. The remagnetisation was acquired before the Middle Eocene collision between the Eastern Pontides and the Arabian Platform because Middle Eocene sandstones carry primary natural remanent magnetisations. The post-folding in situ mean direction of the Upper Cretaceous sandstones is compared with mean directions of younger, Middle Eocene to present rock formations. As a result, a two-stage antagonistic rotation mechanism is proposed. First, the collision between the Pontides and the Taurides between Late Cretaceous and Middle Eocene was associated by clockwise rotation of 26°. In the second stage between Middle Eocene and Middle Miocene and beyond, counterclockwise rotations up to 52° of the Pontide and Anatolide blocks and clockwise rotations of the Van Block were characterised by regional shortening and westward escape.

  20. Note: Device for obtaining volumetric, three-component velocity fields inside cylindrical cavities.

    PubMed

    Ramírez, G; Núñez, J; Hernández, G N; Hernández-Cruz, G; Ramos, E

    2015-11-01

    We describe a device designed and built to obtain the three-component, steady state velocity field in the whole volume occupied by a fluid in motion contained in a cavity with cylindrical walls. The prototype comprises a two-camera stereoscopic particle image velocimetry system mounted on a platform that rotates around the volume under analysis and a slip ring arrangement that transmits data from the rotating sensors to the data storage elements. Sample observations are presented for natural convection in a cylindrical container but other flows can be analyzed.

  1. KSC-99pc0142

    NASA Image and Video Library

    1999-01-28

    The KSC-developed X-33 weight simulator (top), known as the "iron bird," is lifted to a vertical position at the X-33 launch site as part of launch equipment testing on Edwards Air Force Base, CA. The simulator matches the 75,000-pound weight and 63-foot height of the X-33 vehicle that will be using the launch equipment. KSC's Vehicle Positioning System (VPS) placed the simulator on the rotating launch platform prior to the rotation. The new VPS will dramatically reduce the amount of manual labor required to position a reusable launch vehicle for liftoff

  2. KSC-99pc0145

    NASA Image and Video Library

    1999-01-28

    The KSC-developed X-33 weight simulator (top, right), known as the "iron bird," is lifted to a vertical position at the X-33 launch site as part of launch equipment testing on Edwards Air Force Base, CA. The simulator matches the 75,000-pound weight and 63-foot height of the X-33 vehicle that will be using the launch equipment. KSC's Vehicle Positioning System (VPS) placed the simulator on the rotating launch platform prior to the rotation. The new VPS will dramatically reduce the amount of manual labor required to position a reusable launch vehicle for liftoff

  3. KSC-99pc0144

    NASA Image and Video Library

    1999-01-28

    The KSC-developed X-33 weight simulator (left), known as the "iron bird," is fully raised to a vertical position at the X-33 launch site as part of launch equipment testing on Edwards Air Force Base, CA. The simulator matches the 75,000-pound weight and 63-foot height of the X-33 vehicle that will be using the launch equipment. KSC's Vehicle Positioning System (VPS) placed the simulator on the rotating launch platform prior to the rotation. The new VPS will dramatically reduce the amount of manual labor required to position a reusable launch vehicle for liftoff

  4. Electrifying the disk: a modular rotating platform for wireless power and data transmission for Lab on a disk application.

    PubMed

    Höfflin, Jens; Torres Delgado, Saraí M; Suárez Sandoval, Fralett; Korvink, Jan G; Mager, Dario

    2015-06-21

    We present a design for wireless power transfer, via inductively coupled coils, to a spinning disk. The rectified and stabilised power feeds an Arduino-compatible microcontroller (μC) on the disc, which in turn drives and monitors various sensors and actuators. The platform, which has been conceived to flexibly prototype such systems, demonstrates the feasibility of a wireless power supply and the use of a μC circuit, for example for Lab-on-a-disk applications, thereby eliminating the need for cumbersome slip rings or batteries, and adding a cogent and new degree of freedom to the setup. The large number of sensors and actuators included demonstrate that a wide range of physical parameters can be easily monitored and altered. All devices are connected to the μC via an I(2)C bus, therefore can be easily exchanged or augmented by other devices in order to perform a specific task on the disk. The wireless power supply takes up little additional physical space and should work in conjunction with most existing Lab-on-a-disk platforms as a straightforward add-on, since it does not require modification of the rotation axis and can be readily adapted to specific geometrical requirements.

  5. KSC-98pc1180

    NASA Image and Video Library

    1998-09-28

    KENNEDY SPACE CENTER, FLA. -- At left, the payload canister for Space Shuttle Discovery is lifted from its canister movement vehicle to the top of the Rotating Service Structure on Launch Pad 39-B. Discovery (right), sitting atop the Mobile Launch Platform and next to the Fixed Service Structure, is scheduled for launch on Oct. 29, 1998, for the STS-95 mission. That mission includes the International Extreme Ultraviolet Hitchhiker (IEH-3), the Hubble Space Telescope Orbital Systems Test Platform, the Spartan solar-observing deployable spacecraft, and the SPACEHAB single module with experiments on space flight and the aging process

  6. LIMAO: Cross-platform software for simulating laser-induced alignment and orientation dynamics of linear-, symmetric- and asymmetric tops

    NASA Astrophysics Data System (ADS)

    Szidarovszky, Tamás; Jono, Maho; Yamanouchi, Kaoru

    2018-07-01

    A user-friendly and cross-platform software called Laser-Induced Molecular Alignment and Orientation simulator (LIMAO) has been developed. The program can be used to simulate within the rigid rotor approximation the rotational dynamics of gas phase molecules induced by linearly polarized intense laser fields at a given temperature. The software is implemented in the Java and Mathematica programming languages. The primary aim of LIMAO is to aid experimental scientists in predicting and analyzing experimental data representing laser-induced spatial alignment and orientation of molecules.

  7. Haemoglobin content modulated deformation dynamics of red blood cells on a compact disc.

    PubMed

    Kar, Shantimoy; Ghosh, Uddipta; Maiti, Tapas Kumar; Chakraborty, Suman

    2015-12-21

    We investigate the deformation characteristics of red blood cells (RBCs) on a rotating compact disc platform. Our study brings out the interplay between haemoglobin content and RBC deformability in a centrifugally actuated microfluidic environment. We reveal that RBC deformations follow the similar trend of principal stress distributed throughout the radial direction, rendering an insight into the mechano-physical processes involved. This study can be used as a diagnostic marker to determine haematological disorders in diseased blood samples tested on compact disc based microfluidic platforms.

  8. Isokinetic strength differences between patients with primary reverse and total shoulder prostheses: muscle strength quantified with a dynamometer.

    PubMed

    Alta, Tjarco D W; Veeger, DirkJan H E J; de Toledo, Joelly M; Janssen, Thomas W J; Willems, W Jaap

    2014-11-01

    Range of motion after total shoulder arthroplasty is better than after reverse shoulder arthroplasty, however with similar clinical outcome. It is unclear if this difference can only be found in the different range of motion or also in the force generating capacity. (1) are isokinetically produced joint torques of reverse shoulder arthroplasty comparable to those of total shoulder arthroplasty? (2) Does this force-generating capacity correlate with functional outcome? Eighteen reverse shoulder arthroplasty patients (71years (SD 9years)) (21 shoulders, follow-up of 21months (SD 10months)) were recruited, 12 total shoulder arthroplasty patients (69years (SD 9years)) (14 shoulders, follow-up of 35months (SD 11months)). Pre- and post-operative Constant-Murley scores were obtained; two isokinetic protocols (ab-/adduction and ex-/internal rotations) at 60°/s were performed. Twelve of 18 reverse shoulder arthroplasty patients generated enough speed to perform the test (13 shoulders). Mean ab-/adduction torques are 16.3Nm (SD 5.6Nm) and 20.4Nm (SD 11.8Nm). All total shoulder arthroplasty patients generated enough speed (14 shoulders). Mean ab-/adduction torques are 32.1Nm (SD 13.3Nm) and 43.1Nm (SD 21.5Nm). Only 8 reverse shoulder arthroplasty patients (9 shoulders) could perform ex-/internal rotation tasks and all total shoulder arthroplasty patients. Mean ex-/internal rotation torques are 9.3Nm (SD 4.7Nm) and 9.2Nm (SD 2.1Nm) for reverse shoulder arthroplasty, and 17.9Nm (SD 7.7Nm) and 23.5Nm (SD 10.6Nm) for total shoulder arthroplasty. Significant correlations between sub-scores: activity, mobility and strength and external rotation torques for reverse shoulder arthroplasty. Moderate to strong correlation for sub-scores: strength in relation to abduction, adduction and internal rotation torques for total shoulder arthroplasty. Shoulders with a total shoulder arthroplasty are stronger. This can be explained by the absence of rotator cuff muscles and (probably) medialized center of rotation in reverse shoulder arthroplasty. The strong correlation between external rotation torques and post-operative Constant-Murley sub-scores demonstrates that external rotation is essential for good clinical functioning in reverse shoulder arthroplasty. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Control mechanism of double-rotator-structure ternary optical computer

    NASA Astrophysics Data System (ADS)

    Kai, SONG; Liping, YAN

    2017-03-01

    Double-rotator-structure ternary optical processor (DRSTOP) has two characteristics, namely, giant data-bits parallel computing and reconfigurable processor, which can handle thousands of data bits in parallel, and can run much faster than computers and other optical computer systems so far. In order to put DRSTOP into practical application, this paper established a series of methods, namely, task classification method, data-bits allocation method, control information generation method, control information formatting and sending method, and decoded results obtaining method and so on. These methods form the control mechanism of DRSTOP. This control mechanism makes DRSTOP become an automated computing platform. Compared with the traditional calculation tools, DRSTOP computing platform can ease the contradiction between high energy consumption and big data computing due to greatly reducing the cost of communications and I/O. Finally, the paper designed a set of experiments for DRSTOP control mechanism to verify its feasibility and correctness. Experimental results showed that the control mechanism is correct, feasible and efficient.

  10. Coupled simulation of the propulsion system and vehicle using the ESPSS satellite library

    NASA Astrophysics Data System (ADS)

    Koppel, C. R.; Di Matteo, F.; Moral, J.; Steelant, J.

    2018-06-01

    The paper documents the implementation and validation of the coupled simulation of the propulsion system and vehicle performed during the 4th development phase of the ESPSS (European Space Propulsion System Simulation) library running on the existing platform EcosimPro®. This covers a significant update of the spacecraft propulsion system modeling: the Fluid flow, Tanks and Combustion chamber components are updated to allow coupling to the vehicle's motion, the Archimedes pressure coming from acceleration and rotations given by the vehicle or by any perturbation forces are taken into account, several new features are added to the Satellite library along with new components enabling full attitude control of a platform. A new powerful compact equation is presented for solving elegantly the Archimedes pressure coming from combined acceleration and rotation in the most general case (noncollinear). Eventually, a propulsion system is modeled to check the correct implementation of the new components especially those dealing with the effects of the mission on the propulsion subsystem.

  11. Effect of rotational alignment on outcome of total knee arthroplasty

    PubMed Central

    Breugem, Stefan J; van den Bekerom, Michel PJ; Tuinebreijer, Willem E; van Geenen, Rutger C I

    2015-01-01

    Background and purpose Poor outcomes have been linked to errors in rotational alignment of total knee arthroplasty components. The aims of this study were to determine the correlation between rotational alignment and outcome, to review the success of revision for malrotated total knee arthroplasty, and to determine whether evidence-based guidelines for malrotated total knee arthroplasty can be proposed. Patients and methods We conducted a systematic review including all studies reporting on both rotational alignment and functional outcome. Comparable studies were used in a correlation analysis and results of revision were analyzed separately. Results 846 studies were identified, 25 of which met the inclusion criteria. From this selection, 11 studies could be included in the correlation analysis. A medium positive correlation (ρ = 0.44, 95% CI: 0.27–0.59) and a large positive correlation (ρ = 0.68, 95% CI: 0.64–0.73) were found between external rotation of the tibial component and the femoral component, respectively, and the Knee Society score. Revision for malrotation gave positive results in all 6 studies in this field. Interpretation Medium and large positive correlations were found between tibial and femoral component rotational alignment on the one hand and better functional outcome on the other. Revision of malrotated total knee arthroplasty may be successful. However, a clear cutoff point for revision for malrotated total knee arthroplasty components could not be identified. PMID:25708694

  12. Knee braces can decrease tibial rotation during pivoting that occurs in high demanding activities.

    PubMed

    Giotis, Dimitrios; Tsiaras, Vasilios; Ristanis, Stavros; Zampeli, Franceska; Mitsionis, Grigoris; Stergiou, Nicholas; Georgoulis, Anastasios D

    2011-08-01

    The purpose of this study was to investigate whether knee braces could effectively decrease tibial rotation during high demanding activities. Using an in vivo three-dimensional kinematic analysis, 21 physically active, healthy, male subjects were evaluated. Each subject performed two tasks that were used extensively in the literature because they combine increased rotational and translational loads on the knee, (1) descending from a stair and subsequent pivoting and (2) landing from a platform and subsequent pivoting under three conditions: (A) wearing a prophylactic brace (braced), (B) wearing a patellofemoral brace (sleeved), and (C) unbraced condition. In the first task, tibial rotation during the pivoting phase was significantly decreased in the braced condition as compared to the sleeved condition (P = 0.019) and the non-braced condition (P = 0.002). In the second task, the same variable was significantly decreased in the braced condition as compared to the sleeved (P = 0.001) and the unbraced condition (P < 0.001). The sleeved condition also produced significantly decreased tibial rotation with respect to the unbraced condition (P = 0.021). Bracing decreased tibial rotation in activities where increased translational and rotational forces were applied. Because knee braces decreased tibial rotation, they can possibly be used with ACL-reconstructed and ACL-deficient patients to prevent such problems. Case-control study, Level III.

  13. WE-DE-BRA-03: Construction of An Ultrasound Guidance Platform for Image-Guided Radiotherapy with the Intent to Treat Transitional Cell Carcinoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sick, J; Rancilio, N; Fulkerson, C

    Purpose: Ultrasound (US) is a noninvasive, nonradiographic imaging technique with high spatial and temporal resolution that can be used for localizing soft-tissue structures and tumors in real-time during radiotherapy (inter- and intra-fraction). A detailed methodology integrating 3D-US within RT is presented. This method is easier to adopt into current treatment protocol than current US based systems and reduces user variability for image acquisition, thus eliminating transducer induced changes that limit CT planning system. Methods: We designed an in-house integrated US manipulator and platform to relate CT, 3D-US and linear accelerator coordinate systems. To validate the platform, an agar-based phantom withmore » measured densities and speed-of-sound consistent with tissues surrounding the bladder, was rotated (0–45°) resulting in translations (up to 55mm) relative to the CT and US coordinate systems. After acquiring and integrating CT and US images into the treatment planning system, US-to-US and US-to-CT images were co-registered to re-align the phantom relative to the linear accelerator. Errors in the transformation matrix components were calculate to determine precision of this method under different patient positions. Results: Statistical errors from US-US registrations for different patient orientations ranged from 0.06–1.66mm for x, y, and z translational components, and 0.00–1.05° for rotational components. Statistical errors from US-CT registrations were 0.23–1.18mm for the x, y and z translational components, and 0.08–2.52° for the rotational components. Conclusion: Based on our result, this is consistent with currently used techniques for positioning prostate patients if couch re-positioning is less than a 5 degree rotation. We are now testing this on a dog patient to obtain both inter and intra-fractional positional errors. Additional design considerations include the future use of ultrasound-based functionality (photoacoustics, radioacoustics, Doppler) to monitor blood flow and hypoxia and/or in-vivo dosimetry for applications in other therapeutic techniques, such as hyperthermia, anti-angiogenesis, and particle therapy.« less

  14. KSC-02pd0130

    NASA Image and Video Library

    2002-02-14

    KENNEDY SPACE CENTER, FLA. - Sir David Attenborough (center) works with a film crew on Launch Pad 39A. Space Shuttle Columbia, atop the Mobile Launcher Platform, is seen in the background. At left are the Rotating Service Structure, which is open, and the Fixed Service Structure. Attenborough is filming commentary for a documentary

  15. Structures of rotating traditional neutron stars and hyperon stars in the relativistic σ -ω model

    NASA Astrophysics Data System (ADS)

    Wen, De-hua; Chen, Wei; Wang, Xian-ju; Ai, Bao-quan; Liu, Guo-tao; Dong, Dong-qiao; Liu, Liang-gang

    The influence of rotation on the total masses and radii of neutron stars is calculated by Hartle's slow-rotation formalism, while the equation of state is considered in a relativistic σ -ω model. As the changes of the mass and radius of a real neutron star caused by rotation are very small in comparison with the total mass and radius, one can see that Hartle's approximate method is rational to deal with the rotating neutron stars. If three property values, mass, radius and period, are observed for the same neutron star, then the EOS of this neutron star could be decided entirely.

  16. Is it possible to re-establish pre-operative patellar kinematics using a ligament-balanced technique in total knee arthroplasty? A cadaveric investigation.

    PubMed

    Keshmiri, Armin; Springorum, Hans; Baier, Clemens; Zeman, Florian; Grifka, Joachim; Maderbacher, Günther

    2015-03-01

    Several authors emphasise that the appearance of patellar maltracking after total knee arthroplasty (TKA) is caused by rotational malalignment of the femoral and tibial components. Ligament-balanced femoral component rotation was not found to be associated with abnormal postoperative patellar position. We hypothesised that a ligament-balanced technique in TKA has the ability to best re-establish patellar kinematics. In ten cadaveric knees TKA was performed assessing femoral rotation in ligament-balanced and different femoral and tibial component rotation alignments. Patellar kinematics after different component rotations were analysed using a commercial computer navigation system. Ligament-balanced femoral rotation showed the best re-establishment of patellar kinematics after TKA compared to the healthy pre-operative knee. In contrast to tibial component rotation, femoral component rotation had a major impact on patellofemoral kinematics. This investigation suggests that a ligament-balanced technique in TKA is most likely to re-establish natural patellofemoral kinematics. Tibial component rotation did not influence patellar kinematics.

  17. Scanning sky monitor (SSM) onboard AstroSat

    NASA Astrophysics Data System (ADS)

    Ramadevi, M. C.; Seetha, S.; Bhattacharya, Dipankar; Ravishankar, B. T.; Sitaramamurthy, N.; Meena, G.; Sharma, M. Ramakrishna; Kulkarni, Ravi; Babu, V. Chandra; Kumar; Singh, Brajpal; Jain, Anand; Yadav, Reena; Vaishali, S.; Ashoka, B. N.; Agarwal, Anil; Balaji, K.; Nagesh, G.; Kumar, Manoj; Gaan, Dhruti Ranjan; Kulshresta, Prashanth; Agarwal, Pankaj; Sebastian, Mathew; Rajarajan, A.; Radhika, D.; Nandi, Anuj; Girish, V.; Agarwal, Vivek Kumar; Kushwaha, Ankur; Iyer, Nirmal Kumar

    2017-10-01

    Scanning Sky Monitor (SSM) onboard AstroSat is an Xray sky monitor in the soft X-ray band designed with a large field of view to detect and locate transient X-ray sources and alert the astronomical community about interesting phenomena in the X-ray sky. SSM comprises position sensitive proportional counters with 1D coded mask for imaging. There are three detector units mounted on a platform capable of rotation which helps covering about 50% of the sky in one full rotation. This paper discusses the elaborate details of the instrument and few immediate results from the instrument after launch.

  18. Exhibit D modular design attitude control system study

    NASA Technical Reports Server (NTRS)

    Chichester, F.

    1984-01-01

    A dynamically equivalent four body approximation of the NASTRAN finite element model supplied for hybrid deployable truss to support the digital computer simulation of the ten body model of the flexible space platform that incorporates the four body truss model were investigated. Coefficients for sensitivity of state variables of the linearized model of the three axes rotational dynamics of the prototype flexible spacecraft were generated with respect to the model's parameters. Software changes required to accommodate addition of another rigid body to the five body model of the rotational dynamics of the prototype flexible spacecraft were evaluated.

  19. KSC-08pd2799

    NASA Image and Video Library

    2008-09-21

    CAPE CANAVERAL, Fla. - On Launch Pad 39A at NASA's Kennedy Space Center, the payload canister is in place at the payload changeout room on the rotating service structure. The canister contains four carriers holding various equipment for the STS-125 mission aboard space shuttle Atlantis to service NASA’s Hubble Space Telescope. At right is Atlantis, atop the mobile launcher platform. The changeout room is the enclosed, environmentally controlled portion of the rotating service structure that supports cargo delivery to the pad and subsequent vertical installation into the shuttle’s payload bay. Launch of Atlantis is targeted for Oct. 10. Photo credit: NASA/Jack Pfaller

  20. KSC-99pc0143

    NASA Image and Video Library

    1999-01-28

    As part of X-33 launch equipment testing at Edwards Air Force Base, CA, the KSC-developed X-33 weight simulator (top), known as the "iron bird," is lifted to a vertical position at the X-33 launch site. The simulator matches the 75,000-pound weight and 63-foot height of the X-33 vehicle that will be using the launch equipment. KSC's Vehicle Positioning System (VPS) placed the simulator on the rotating launch platform prior to the rotation. The new VPS will dramatically reduce the amount of manual labor required to position a reusable launch vehicle for liftoff

  1. What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?: A 5-10 years followup by a nondesigner.

    PubMed

    Vaidya, Shrinand V; Virani, Siddharth; Phunde, Rajendra; Mahajan, Abhishek

    2016-01-01

    Total joint arthroplasties of the hip and knee represent a remarkable feat of modern medicine in terms of reducing pain and restoring function to millions of patients afflicted with severe arthritis. Oftentimes, the performance and longevity of new implants and devices are based on limited data. This is the first study by a non-designer on the press fit condylar rotating platform posterior stabilized (PFC-RP-PS) design with 100' success. This has a relevance, vis-á -vis bias that one may have in terms of reproducibility of technique and funding from the manufacturer. We associate our excellent mid-term results to intra operative technical aspects and stringent intra operative exclusion criteria. Our study includes a cohort of 121 selected knees operated between January 2003 and October 2010. We used cemented, posterior stabilized (PS), mobile bearing (MB), and RP prosthesis from the same manufacturer in all these 121 knees. The patients were evaluated bi-annually with the calculation of their Knee Society Scores (KSS) and a radiological assessment for loosening/osteolysis. 120 knees were available for followup. The average Knee Society clinical and functional scores, respectively, were 27 points and 40 points preoperatively and 93 points and 95 points postoperatively. This indicates a mean increase of about 71' in the clinical score and about 58' in the functional score, which is statistically significant. The mean postoperative flexion was 124°, a mean increase of 23° from the preoperative flexion of 101°. There were no revisions (Kaplan--Meier survivorship of 100'). We feel durable and reproducible results of PFC-RP-PS design knees are very technique sensitive. The way ahead with the PFC-RP-PS knees looks promising when the exclusion criteria for this design are strictly met. Coming from a non-designer, this study acquires a higher degree of relevance without any designer's or manufacturer's bias.

  2. Primate-inspired vehicle navigation using optic flow and mental rotations

    NASA Astrophysics Data System (ADS)

    Arkin, Ronald C.; Dellaert, Frank; Srinivasan, Natesh; Kerwin, Ryan

    2013-05-01

    Robot navigation already has many relatively efficient solutions: reactive control, simultaneous localization and mapping (SLAM), Rapidly-Exploring Random Trees (RRTs), etc. But many primates possess an additional inherent spatial reasoning capability: mental rotation. Our research addresses the question of what role, if any, mental rotations can play in enhancing existing robot navigational capabilities. To answer this question we explore the use of optical flow as a basis for extracting abstract representations of the world, comparing these representations with a goal state of similar format and then iteratively providing a control signal to a robot to allow it to move in a direction consistent with achieving that goal state. We study a range of transformation methods to implement the mental rotation component of the architecture, including correlation and matching based on cognitive studies. We also include a discussion of how mental rotations may play a key role in understanding spatial advice giving, particularly from other members of the species, whether in map-based format, gestures, or other means of communication. Results to date are presented on our robotic platform.

  3. Use of a platform in an automated open-field to enhance assessment of anxiety-like behaviors in mice.

    PubMed

    Pogorelov, Vladimir M; Lanthorn, Thomas H; Savelieva, Katerina V

    2007-05-15

    The present report describes a setup for simultaneously measuring anxiety-like behaviors and locomotor activity in mice. Animals are placed in a brightly lit, standard automated open-field (OF) in which a rectangular ceramic platform 8 cm high covers one quadrant of the floor. Mice preferred to stay under the platform, avoiding the area with bright illumination. Activities under and outside the platform were measured for 5 min. Chlordiazepoxide and buspirone dose-dependently increased time spent outside the platform (L-Time) and the light distance to total OF distance ratio (L:T-TD) in both genders without changing total OF distance. By contrast, amphetamine decreased L-Time and L:T-TD in males, thus displaying an anxiogenic effect. Imipramine was without selective effect on L-Time or L:T-TD, but decreased total OF distance at the highest dose indicative of a sedative effect. Drug effects were also evaluated in the OF without platform using conventional anxiety measures. Introduction of the platform into the OF apparatus strongly enhanced the sensitivity to anxiolytics. Comparison of strains differing in activity or anxiety levels showed that L-Time and L:T-TD can be used as measures of anxiety-like behavior independent of locomotor activity. Changes in motor activity are reflected in the total distance traveled under and outside the platform. Therefore, the platform test is fully automated, sensitive to both anxiolytic and anxiogenic effects of drugs and genetic phenotypes with little evidence of gender-specific responses, and can be easily utilized by most laboratories measuring behavior.

  4. Light diffraction studies of single muscle fibers as a function of fiber rotation.

    PubMed Central

    Gilliar, W G; Bickel, W S; Bailey, W F

    1984-01-01

    Light diffraction patterns from single glycerinated frog semitendinosus muscle fibers were examined photographically and photoelectrically as a function of diffraction angle and fiber rotation. The total intensity diffraction pattern indicates that the order maxima change both position and intensity periodically as a function of rotation angle. The total diffracted light, light diffracted above and below the zero-order plane, and light diffracted into individual orders gives information about the fiber's longitudinal and rotational structure and its noncylindrical symmetry. Images FIGURE 2 PMID:6611174

  5. Low profile, high load vertical rolling positioning stage

    DOEpatents

    Shu, Deming; Barraza, Juan

    1996-01-01

    A stage or support platform assembly for use in a synchrotron accurately positions equipment to be used in the beam line of the synchrotron. The support platform assembly includes an outer housing in which is disposed a lifting mechanism having a lifting platform or stage at its upper extremity on which the equipment is mounted. A worm gear assembly is located in the housing and is adapted to raise and lower a lifting shaft that is fixed to the lifting platform by an anti-binding connection. The lifting platform is moved vertically as the lifting shaft is moved vertically. The anti-binding connection prevents the shaft from rotating with respect to the platform, but does permit slight canting of the shaft with respect to the lifting platform so as to eliminate binding and wear due to possible tolerance mismatches. In order to ensure that the lifting mechanism does not move in a horizontal direction as it is moved vertically, at least three linear roller bearing assemblies are arranged around the outer-periphery of the lifting mechanism. One of the linear roller bearing assemblies can be adjusted so that the roller bearings apply a loading force against the lifting mechanism. Alternatively, a cam mechanism can be used to provide such a loading force.

  6. General surgery resident rotations in surgical critical care, trauma, and burns: what is optimal for residency training?

    PubMed

    Napolitano, Lena M; Biester, Thomas W; Jurkovich, Gregory J; Buyske, Jo; Malangoni, Mark A; Lewis, Frank R

    2016-10-01

    There are no specific Accreditation Council for Graduate Medical Education General Surgery Residency Program Requirements for rotations in surgical critical care (SCC), trauma, and burn. We sought to determine the experience of general surgery residents in SCC, trauma, and burn rotations. Data analysis of surgical rotations of American Board of Surgery general surgery resident applicants (n = 7,299) for the last 8 years (2006 to 2013, inclusive) was performed through electronic applications to the American Board of Surgery Qualifying Examination. Duration (months) spent in SCC, trauma, and burn rotations, and postgraduate year (PGY) level were examined. The total months in SCC, trauma and burn rotations was mean 10.2 and median 10.0 (SD 3.9 months), representing approximately 16.7% (10 of 60 months) of a general surgery resident's training. However, there was great variability (range 0 to 29 months). SCC rotation duration was mean 3.1 and median 3.0 months (SD 2, min to max: 0 to 15), trauma rotation duration was mean 6.3 and median 6.0 months (SD 3.5, min to max: 0 to 24), and burn rotation duration was mean 0.8 and median 1.0 months (SD 1.0, min to max: 0 to 6). Of the total mean 10.2 months duration, the longest exposure was 2 months as PGY-1, 3.4 months as PGY-2, 1.9 months as PGY-3, 2.2 months as PGY-4 and 1.1 months as PGY-5. PGY-5 residents spent a mean of 1 month in SCC, trauma, and burn rotations. PGY-4/5 residents spent the majority of this total time in trauma rotations, whereas junior residents (PGY-1 to 3) in SCC and trauma rotations. There is significant variability in total duration of SCC, trauma, and burn rotations and PGY level in US general surgery residency programs, which may result in significant variability in the fund of knowledge and clinical experience of the trainee completing general surgery residency training. As acute care surgery programs have begun to integrate emergency general surgery with SCC, trauma, and burn rotations, it is an ideal time to determine the optimal curriculum and duration of these important rotations for general surgery residency training. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Reliability of Measurement of Glenohumeral Internal Rotation, External Rotation, and Total Arc of Motion in 3 Test Positions

    PubMed Central

    Kevern, Mark A.; Beecher, Michael; Rao, Smita

    2014-01-01

    Context: Athletes who participate in throwing and racket sports consistently demonstrate adaptive changes in glenohumeral-joint internal and external rotation in the dominant arm. Measurements of these motions have demonstrated excellent intrarater and poor interrater reliability. Objective: To determine intrarater reliability, interrater reliability, and standard error of measurement for shoulder internal rotation, external rotation, and total arc of motion using an inclinometer in 3 testing procedures in National Collegiate Athletic Association Division I baseball and softball athletes. Design: Cross-sectional study. Setting: Athletic department. Patients or Other Participants Thirty-eight players participated in the study. Shoulder internal rotation, external rotation, and total arc of motion were measured by 2 investigators in 3 test positions. The standard supine position was compared with a side-lying test position, as well as a supine test position without examiner overpressure. Results: Excellent intrarater reliability was noted for all 3 test positions and ranges of motion, with intraclass correlation coefficient values ranging from 0.93 to 0.99. Results for interrater reliability were less favorable. Reliability for internal rotation was highest in the side-lying position (0.68) and reliability for external rotation and total arc was highest in the supine-without-overpressure position (0.774 and 0.713, respectively). The supine-with-overpressure position yielded the lowest interrater reliability results in all positions. The side-lying position had the most consistent results, with very little variation among intraclass correlation coefficient values for the various test positions. Conclusions: The results of our study clearly indicate that the side-lying test procedure is of equal or greater value than the traditional supine-with-overpressure method. PMID:25188316

  8. Virtual Distances Methodology as Verification Technique for AACMMs with a Capacitive Sensor Based Indexed Metrology Platform.

    PubMed

    Acero, Raquel; Santolaria, Jorge; Brau, Agustin; Pueo, Marcos

    2016-11-18

    This paper presents a new verification procedure for articulated arm coordinate measuring machines (AACMMs) together with a capacitive sensor-based indexed metrology platform (IMP) based on the generation of virtual reference distances. The novelty of this procedure lays on the possibility of creating virtual points, virtual gauges and virtual distances through the indexed metrology platform's mathematical model taking as a reference the measurements of a ball bar gauge located in a fixed position of the instrument's working volume. The measurements are carried out with the AACMM assembled on the IMP from the six rotating positions of the platform. In this way, an unlimited number and types of reference distances could be created without the need of using a physical gauge, therefore optimizing the testing time, the number of gauge positions and the space needed in the calibration and verification procedures. Four evaluation methods are presented to assess the volumetric performance of the AACMM. The results obtained proved the suitability of the virtual distances methodology as an alternative procedure for verification of AACMMs using the indexed metrology platform.

  9. Influence of Electrotactile Tongue Feedback on Controlling Upright Stance during Rotational and/or Translational Sway-referencing with Galvanic Vestibular Stimulation

    NASA Technical Reports Server (NTRS)

    Wood, Scott J.; Tyler, Mitchell E.; Bach-y-Rita, Paul; MacDougall, Hamish G.; Moore, Steven T.; Stallings, Valerie L.; Paloski, William H.; Black, F. Owen

    2007-01-01

    Integration of multi-sensory inputs to detect tilts relative to gravity is critical for sensorimotor control of upright orientation. Displaying body orientation using electrotactile feedback to the tongue has been developed by Bach-y-Rita and colleagues as a sensory aid to maintain upright stance with impaired vestibular feedback. MacDougall et al. (2006) recently demonstrated that unpredictably varying Galvanic vestibular stimulation (GVS) significantly increased anterior-posterior (AP) sway during rotational sway referencing with eyes closed. The purpose of this study was to assess the influence of electrotactile feedback on postural control performance with pseudorandom binaural bipolar GVS. Postural equilibrium was measured with a computerized hydraulic platform in 10 healthy adults (6M, 4F, 24-65 y). Tactile feedback (TF) of pitch and roll body orientation was derived from a two-axis linear accelerometer mounted on a torso belt and displayed on a 144-point electrotactile array held against the anterior dorsal tongue (BrainPort, Wicab, Inc., Middleton, WI). Subjects were trained to use TF by voluntarily swaying to draw figures on their tongue, both with and without GVS. Subjects were required to keep the intraoral display in their mouths on all trials, including those that did not provide TF. Subjects performed 24 randomized trials (20 s duration with eyes closed) including four support surface conditions (fixed, rotational sway-referenced, translating the support surface proportional to AP sway, and combined rotational-translational sway-referencing), each repeated twice with and without GVS, and with combined GVS and TF. Postural performance was assessed using deviations from upright (peak-to-peak and RMS sway) and convergence toward stability limits (time and distance to base of support boundaries). Postural stability was impaired with GVS in all platform conditions, with larger decrements in performance during trials with rotation sway-referencing. Electrotactile feedback improved performance with GVS toward non-GVS levels, again with the greatest improvement during trials with rotation sway-referencing. These results demonstrate the effectiveness of tongue electrotactile feedback in providing sensory substitution to maintain postural stability with distorted vestibular input.

  10. Stability of soil organic carbon changes in successive rotations of Chinese fir (Cunninghamia lanceolata (Lamb.) Hook) plantations.

    PubMed

    Zhang, Jian; Wang, Silong; Feng, Zongwei; Wang, Qingkui

    2009-01-01

    The importance of soil organic carbon (SOC) under forests in the global carbon cycle depends on the stability of the soil carbon and its availability to soil microbial biomass. We investigated the effects of successive rotations of Chinese fir (Cunninghamia lanceolata (Lamb.) Hook) plantations on the stability of SOC and its availability to microbes by adopting the two-step hydrolysis with H2SO4 and density fractionation. The results showed that successive rotations of Chinese fir decreased the quantity of total SOC, recalcitrant fraction, and carbohydrates in Labile Pool I (LP I), and microbial properties evidently, especially at 0-10 cm horizon. However, cellulose included in Labile Pool II (LP II) and the cellulose/total carbohydrates ratio increased in successive rotations of Chinese fir. The non-cellulose of carbohydrates included in LP I maybe highly available to soil microbial biomass. Hence the availability of SOC to microbial biomass declined over the successive rotations. Although there was no significant change in recalcitrance of SOC over the successive rotations of Chinese fir, the percentage of heavy fraction to total SOC increased, suggesting that the degree of physical protection for SOC increased and SOC became more stable over the successive rotations. The degradation of SOC quality in successive rotation soils may be attributed to worse environmental conditions resulted from disturbance that related to "slash and burn" site preparation. Being highly correlated with soil microbial properties, the cellulose/total carbohydrates ratio as an effective indicator of changes in availability of SOC to microbial biomass brought by management practices in forest soils.

  11. Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?

    PubMed

    Figueroa, José; Guarachi, Juan Pablo; Matas, José; Arnander, Magnus; Orrego, Mario

    2016-04-01

    Computed tomography (CT) is widely used to assess component rotation in patients with poor results after total knee arthroplasty (TKA). The purpose of this study was to simultaneously determine the accuracy and reliability of CT in measuring TKA component rotation. TKA components were implanted in dry-bone models and assigned to two groups. The first group (n = 7) had variable femoral component rotations, and the second group (n = 6) had variable tibial tray rotations. CT images were then used to assess component rotation. Accuracy of CT rotational assessment was determined by mean difference, in degrees, between implanted component rotation and CT-measured rotation. Intraclass correlation coefficient (ICC) was applied to determine intra-observer and inter-observer reliability. Femoral component accuracy showed a mean difference of 2.5° and the tibial tray a mean difference of 3.2°. There was good intra- and inter-observer reliability for both components, with a femoral ICC of 0.8 and 0.76, and tibial ICC of 0.68 and 0.65, respectively. CT rotational assessment accuracy can differ from true component rotation by approximately 3° for each component. It does, however, have good inter- and intra-observer reliability.

  12. Microbial Monitoring of Pathogens by Comparing Multiple Real-Time PCR Platforms for Potential Space Applications

    NASA Technical Reports Server (NTRS)

    Birmele, Michele

    2012-01-01

    The International Space Station (ISS) is a closed environment wih rotations of crew and equipment each introducing their own microbial flora making it necessary to monitor the air, surfaces, and water for microbial contamination. Current microbial monitoring includes labor and time intensive methods to enumerate total bacterial and fungal cells with limited characterization during in-flight testing. Although this culture-based method has been sufficient for monitoring the ISS, future long duration missions will need to perform more comprehensive characterization in-flight, since sample return and ground characterization may not be available. A workshop was held in 2011 at the Johnson Space Center to discuss alternative methodologies and technologies suitable for microbial monitoring for these longterm exploration missions where molecular-based methodologies, such as polymerase chain reaction (PCR), were recommended. In response, a multi-center (Marshall Space Flight Center, Johnson Space Center, Jet Propulsion Laboratory, and Kennedy Space Center) collaborative research effort was initiated to explore novel commercial-off-the-shelf hardware options for spaceflight environmental monitoring. The goal was to evaluate quantitative/semi-quantitative PCR approaches to space applications for low cost in-flight rapid identification of microorganisms affecting crew safety. The initial phase of this project identified commercially available platforms that could be minimally modified to perform nominally in microgravity followed by proof-of-concept testing on the highest qualifying candidates with a universally available test organism, Salmonella enterica. The platforms evaluated during proof-of-concept testing included the iCubate 2.0(TradeMark) (iCubate, Huntsville, AL), RAZOR EX (BioFire Diagnostics; Salt Lake City, Utah) and SmartCycler(TradeMark) (Cepheid; Sunnyvale, CA). The analysis identified two potential technologies (iCubate 2.0 and RAZOR EX) that were able to perform sample-to-answer testing with cell sample concentrations between SO to 400 cells. In addition, the commercial systems were evaluated for initial flight safety and readiness, sample concentration needs were reviewed, and a competitive procurement of commercially available platforms was initiated.

  13. Centrifugo-pneumatic valving utilizing dissolvable films.

    PubMed

    Gorkin, Robert; Nwankire, Charles E; Gaughran, Jennifer; Zhang, Xin; Donohoe, Gerard G; Rook, Martha; O'Kennedy, Richard; Ducrée, Jens

    2012-08-21

    In this article we introduce a novel technology that utilizes specialized water dissolvable thin films for valving in centrifugal microfluidic systems. In previous work (William Meathrel and Cathy Moritz, IVD Technologies, 2007), dissolvable films (DFs) have been assembled in laminar flow devices to form efficient sacrificial valves where DFs simply open by direct contact with liquid. Here, we build on the original DF valving scheme to leverage sophisticated, merely rotationally actuated vapour barriers and flow control for enabling comprehensive assay integration with low-complexity instrumentation on "lab-on-a-disc" platforms. The advanced sacrificial valving function is achieved by creating an inverted gas-liquid stack upstream of the DF during priming of the system. At low rotational speeds, a pocket of trapped air prevents a surface-tension stabilized liquid plug from wetting the DF membrane. However, high-speed rotation disrupts the metastable gas/liquid interface to wet the DF and thus opens the valve. By judicious choice of the radial position and geometry of the valve, the burst frequency can be tuned over a wide range of rotational speeds nearly 10 times greater than those attained by common capillary burst valves based on hydrophobic constrictions. The broad range of reproducible burst frequencies of the DF valves bears the potential for full integration and automation of comprehensive, multi-step biochemical assay protocols. In this report we demonstrate DF valving, discuss the biocompatibility of using the films, and show a potential sequential valving system including the on-demand release of on-board stored liquid reagents, fast centrifugal sedimentation and vigorous mixing; thus providing a viable basis for use in lab-on-a-disc platforms for point-of-care diagnostics and other life science applications.

  14. Far Ultraviolet Imaging from the Image Spacecraft

    NASA Technical Reports Server (NTRS)

    Mende, S. B.; Heetderks, H.; Frey, H. U.; Lampton, M.; Geller, S. P.; Stock, J. M.; Abiad, R.; Siegmund, O. H. W.; Tremsin, A. S.; Habraken, S.

    2000-01-01

    Direct imaging of the magnetosphere by the IMAGE spacecraft will be supplemented by observation of the global aurora. The IMAGE satellite instrument complement includes three Far Ultraviolet (FUV) instruments. The Wideband Imaging Camera (WIC) will provide broad band ultraviolet images of the aurora for maximum spatial and temporal resolution by imaging the LBH N2 bands of the aurora. The Spectrographic Imager (SI), a novel form of monochromatic imager, will image the aurora, filtered by wavelength. The proton-induced component of the aurora will be imaged separately by measuring the Doppler-shifted Lyman-a. Finally, the GEO instrument will observe the distribution of the geocoronal emission to obtain the neutral background density source for charge exchange in the magnetosphere. The FUV instrument complement looks radially outward from the rotating IMAGE satellite and, therefore, it spends only a short time observing the aurora and the Earth during each spin. To maximize photon collection efficiency and use efficiently the short time available for exposures the FUV auroral imagers WIC and SI both have wide fields of view and take data continuously as the auroral region proceeds through the field of view. To minimize data volume, the set of multiple images are electronically co-added by suitably shifting each image to compensate for the spacecraft rotation. In order to minimize resolution loss, the images have to be distort ion-corrected in real time. The distortion correction is accomplished using high speed look up tables that are pre-generated by least square fitting to polynomial functions by the on-orbit processor. The instruments were calibrated individually while on stationary platforms, mostly in vacuum chambers. Extensive ground-based testing was performed with visible and near UV simulators mounted on a rotating platform to emulate their performance on a rotating spacecraft.

  15. Engine-driven preparation of curved root canals: measuring cyclic fatigue and other physical parameters.

    PubMed

    Peters, Ove A; Kappeler, Stefan; Bucher, Willi; Barbakow, Fred

    2002-04-01

    An increasing number of engine-driven rotary systems are marketed to shape root canals. Although these systems may improve the quality of canal preparations, the risk for instrument fracture is also increased. Unfortunately, the stresses generated in rotary instruments when shaping curved root canals have not been adequately studied. Consequently, the aim of an ongoing project was to develop a measurement platform that could more accurately detail physical parameters generated in a simulated clinical situation. Such a platform was constructed by fitting a torque-measuring device between the rotating endodontic instrument and the motor driving it. Apically directed force and instrument insertion depth were also recorded. Additional devices were constructed to assess cyclic fatigue and static fracture loads. The current pilot study evaluated GT rotary instruments during the shaping of curved canals in plastic blocks as well as "ISO 3630-1 torque to fracture" and number of rotations required for fatigue fracture. Results indicated that torques in excess of 40 Nmm were generated by rotary GT-Files, a significantly higher figure than static fracture loads (less than 13 Nmm for the size 20. 12 GT-File). Furthermore, the number of rotations needed to shape simulated canals with a 5 mm radius of curvature in plastic blocks was 10 times lower than the number of rotations needed to fracture instruments in a "cyclic fatigue test". Apical forces were always greater than 1 N, and in some specimens, scores of 8 N or more were recorded. Further studies are required using extracted natural teeth, with their wide anatomical variation, in order to reduce the incidence of fracture of rotary instruments. In this way, the clinical potential of engine-driven rotary instruments to safely prepare curved canals can be fully appreciated.

  16. Settling dynamics of asymmetric rigid fibers

    Treesearch

    E.J. Tozzi; C Tim Scott; David Vahey; D.J. Klingenberg

    2011-01-01

    The three-dimensional motion of asymmetric rigid fibers settling under gravity in a quiescent fluid was experimentally measured using a pair of cameras located on a movable platform. The particle motion typically consisted of an initial transient after which the particle approached a steady rate of rotation about an axis parallel to the acceleration of gravity, with...

  17. Motion picture history of the erection and operation of the Smith-Putnam wind generator

    NASA Technical Reports Server (NTRS)

    Wilcox, C.

    1973-01-01

    A color movie presentation is discussed that presents the various stages in assemblying the major subsystems of a synchronous wind generator, such as installing the rotor blades and the rotating platform at the top of the tower. In addition scenes are shown of the wind generator in operation.

  18. Cabana Multi-User Spaceport Tour of KSC

    NASA Image and Video Library

    2017-02-17

    Inside Boeing’s Commercial Crew and Cargo Processing Facility at NASA's Kennedy Space Center in Florida members of the news media view work platforms that will be used in manufacturing Boeing's CST-100 Starliner spacecraft for flight tests and crew rotation missions to the International Space Station as part of the agency's Commercial Crew Program.

  19. An Inversion Recovery NMR Kinetics Experiment

    ERIC Educational Resources Information Center

    Williams, Travis J.; Kershaw, Allan D.; Li, Vincent; Wu, Xinping

    2011-01-01

    A convenient laboratory experiment is described in which NMR magnetization transfer by inversion recovery is used to measure the kinetics and thermochemistry of amide bond rotation. The experiment utilizes Varian spectrometers with the VNMRJ 2.3 software, but can be easily adapted to any NMR platform. The procedures and sample data sets in this…

  20. Pathology informatics fellowship retreats: The use of interactive scenarios and case studies as pathology informatics teaching tools.

    PubMed

    Lee, Roy E; McClintock, David S; Balis, Ulysses J; Baron, Jason M; Becich, Michael J; Beckwith, Bruce A; Brodsky, Victor B; Carter, Alexis B; Dighe, Anand S; Haghighi, Mehrvash; Hipp, Jason D; Henricks, Walter H; Kim, Jiyeon Y; Klepseis, Veronica E; Kuo, Frank C; Lane, William J; Levy, Bruce P; Onozato, Maristela L; Park, Seung L; Sinard, John H; Tuthill, Mark J; Gilbertson, John R

    2012-01-01

    Last year, our pathology informatics fellowship added informatics-based interactive case studies to its existing educational platform of operational and research rotations, clinical conferences, a common core curriculum with an accompanying didactic course, and national meetings. The structure of the informatics case studies was based on the traditional business school case study format. Three different formats were used, varying in length from short, 15-minute scenarios to more formal multiple hour-long case studies. Case studies were presented over the course of three retreats (Fall 2011, Winter 2012, and Spring 2012) and involved both local and visiting faculty and fellows. Both faculty and fellows found the case studies and the retreats educational, valuable, and enjoyable. From this positive feedback, we plan to incorporate the retreats in future academic years as an educational component of our fellowship program. Interactive case studies appear to be valuable in teaching several aspects of pathology informatics that are difficult to teach in more traditional venues (rotations and didactic class sessions). Case studies have become an important component of our fellowship's educational platform.

  1. Three legged walking mobile platform: Kinematic and dynamic analysis and simulation

    NASA Technical Reports Server (NTRS)

    Mcmurray, Gary V.; Maclaren, Brice K.

    1988-01-01

    The three legged walker is proposed as a mobile work platform for numerous tasks associated with lunar base site preparation and construction. It is seen as one of several forms of surface transportation, each of which will be best suited for its respective tasks. Utilizing the principle of dynamic stability and taking advantage of the Moon's gravity, it appears to be capable of walking in any radial direction and rotating about a point. Typical curved path walking could involve some combination of the radial and rotational movements. Comprised mainly of a body, six actuators, and six moving parts, it is mechanically quite simple. Each leg connects to the body at a hip joint and has a femur, a knee joint, and a tibia that terminates at a foot. Also capable of enabling or enhancing the dexterity of a series of implements, the walker concept provides a mechanically simple and weight efficient means of drilling, digging, mining, and transporting cargo, and performing other like tasks. A proof of principle machine demonstrated the feasibility of the walking concept.

  2. Hip2Norm: an object-oriented cross-platform program for 3D analysis of hip joint morphology using 2D pelvic radiographs.

    PubMed

    Zheng, G; Tannast, M; Anderegg, C; Siebenrock, K A; Langlotz, F

    2007-07-01

    We developed an object-oriented cross-platform program to perform three-dimensional (3D) analysis of hip joint morphology using two-dimensional (2D) anteroposterior (AP) pelvic radiographs. Landmarks extracted from 2D AP pelvic radiographs and optionally an additional lateral pelvic X-ray were combined with a cone beam projection model to reconstruct 3D hip joints. Since individual pelvic orientation can vary considerably, a method for standardizing pelvic orientation was implemented to determine the absolute tilt/rotation. The evaluation of anatomically morphologic differences was achieved by reconstructing the projected acetabular rim and the measured hip parameters as if obtained in a standardized neutral orientation. The program had been successfully used to interactively objectify acetabular version in hips with femoro-acetabular impingement or developmental dysplasia. Hip(2)Norm is written in object-oriented programming language C++ using cross-platform software Qt (TrollTech, Oslo, Norway) for graphical user interface (GUI) and is transportable to any platform.

  3. OCILOW-Wheeled Platform Controls Executable Set

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jansen, John F.

    2005-11-30

    The OCILOW Controls Executable Set is the complete set of machine executable instructions to control the motion of wheeled platforms that incorporate Off-Centered In-Line Omni-directional Wheels (OCILOW). The controls utilize command signals for the desired motion of the platform (X, Y and Theta) and calculate and control the steering and rolling motion required of each OCILOW wheels to achieve the desired translational and rotational platform motion. The controls utilize signals from the wheel steering and rolling resolvers, and from three load cells located at each wheels, to coordinate the motion of all wheels, while respecting their non-holonomic constraints (i.e., keepingmore » internal stresses and slippage due to possible errors, uneven floors, bumps, misalignment, etc. bounded). The OCILOW Controls Executable Set, which is copyrighted here, is an embodiment of the generic OCILOW algorithms (patented separately) developed specifically for controls of the Proof-of-Principle-Transporter (POP-T) system that has been developed to demonstrate the overall OCILOW controls feasibility and capabilities.« less

  4. Microscale screening systems for 3D cellular microenvironments: platforms, advances, and challenges

    PubMed Central

    Montanez-Sauri, Sara I.; Beebe, David J.; Sung, Kyung Eun

    2015-01-01

    The increasing interest in studying cells using more in vivo-like three-dimensional (3D) microenvironments has created a need for advanced 3D screening platforms with enhanced functionalities and increased throughput. 3D screening platforms that better mimic in vivo microenvironments with enhanced throughput would provide more in-depth understanding of the complexity and heterogeneity of microenvironments. The platforms would also better predict the toxicity and efficacy of potential drugs in physiologically relevant conditions. Traditional 3D culture models (e.g. spinner flasks, gyratory rotation devices, non-adhesive surfaces, polymers) were developed to create 3D multicellular structures. However, these traditional systems require large volumes of reagents and cells, and are not compatible with high throughput screening (HTS) systems. Microscale technology offers the miniaturization of 3D cultures and allows efficient screening of various conditions. This review will discuss the development, most influential works, and current advantages and challenges of microscale culture systems for screening cells in 3D microenvironments. PMID:25274061

  5. Algorithms and uncertainties for the determination of multispectral irradiance components and aerosol optical depth from a shipborne rotating shadowband radiometer

    NASA Astrophysics Data System (ADS)

    Witthuhn, Jonas; Deneke, Hartwig; Macke, Andreas; Bernhard, Germar

    2017-03-01

    The 19-channel rotating shadowband radiometer GUVis-3511 built by Biospherical Instruments provides automated shipborne measurements of the direct, diffuse and global spectral irradiance components without a requirement for platform stabilization. Several direct sun products, including spectral direct beam transmittance, aerosol optical depth, Ångström exponent and precipitable water, can be derived from these observations. The individual steps of the data analysis are described, and the different sources of uncertainty are discussed. The total uncertainty of the observed direct beam transmittances is estimated to be about 4 % for most channels within a 95 % confidence interval for shipborne operation. The calibration is identified as the dominating contribution to the total uncertainty. A comparison of direct beam transmittance with those obtained from a Cimel sunphotometer at a land site and a manually operated Microtops II sunphotometer on a ship is presented. Measurements deviate by less than 3 and 4 % on land and on ship, respectively, for most channels and in agreement with our previous uncertainty estimate. These numbers demonstrate that the instrument is well suited for shipborne operation, and the applied methods for motion correction work accurately. Based on spectral direct beam transmittance, aerosol optical depth can be retrieved with an uncertainty of 0.02 for all channels within a 95 % confidence interval. The different methods to account for Rayleigh scattering and gas absorption in our scheme and in the Aerosol Robotic Network processing for Cimel sunphotometers lead to minor deviations. Relying on the cross calibration of the 940 nm water vapor channel with the Cimel sunphotometer, the column amount of precipitable water can be estimated with an uncertainty of ±0.034 cm.

  6. Using the Flow-3D General Moving Object Model to Simulate Coupled Liquid Slosh - Container Dynamics on the SPHERES Slosh Experiment: Aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Schulman, Richard; Kirk, Daniel; Marsell, Brandon; Roth, Jacob; Schallhorn, Paul

    2013-01-01

    The SPHERES Slosh Experiment (SSE) is a free floating experimental platform developed for the acquisition of long duration liquid slosh data aboard the International Space Station (ISS). The data sets collected will be used to benchmark numerical models to aid in the design of rocket and spacecraft propulsion systems. Utilizing two SPHERES Satellites, the experiment will be moved through different maneuvers designed to induce liquid slosh in the experiment's internal tank. The SSE has a total of twenty-four thrusters to move the experiment. In order to design slosh generating maneuvers, a parametric study with three maneuvers types was conducted using the General Moving Object (GMO) model in Flow-30. The three types of maneuvers are a translation maneuver, a rotation maneuver and a combined rotation translation maneuver. The effectiveness of each maneuver to generate slosh is determined by the deviation of the experiment's trajectory as compared to a dry mass trajectory. To fully capture the effect of liquid re-distribution on experiment trajectory, each thruster is modeled as an independent force point in the Flow-3D simulation. This is accomplished by modifying the total number of independent forces in the GMO model from the standard five to twenty-four. Results demonstrate that the most effective slosh generating maneuvers for all motions occurs when SSE thrusters are producing the highest changes in SSE acceleration. The results also demonstrate that several centimeters of trajectory deviation between the dry and slosh cases occur during the maneuvers; while these deviations seem small, they are measureable by SSE instrumentation.

  7. Differential color brightness as a body orientation cue

    NASA Technical Reports Server (NTRS)

    Barbour, Christopher G.; Coss, Richard G.

    1988-01-01

    Ninety male and female college students reclining on their backs in the dark were disoriented when positioned on a rotating platform under a slowly rotating disk that filled their entire visual field. Half of the disk was painted with a brighter value (about 69 percent higher luminance level) of the color on the other half. The effects of red, blue, and yellow were examined. Subjects wearing frosted goggles viewed the illuminated disk for three rotations. The disk was stopped when the subjects felt that they were right side up. A significant proportion of subjects selected the disk position in which the brighter side of each of the three colors filled their upper visual field. These results suggest that color brightness as well as lighting variation could provide Space Station crew members with body orientation cues as they move around.

  8. Autonomous navigation system and method

    DOEpatents

    Bruemmer, David J [Idaho Falls, ID; Few, Douglas A [Idaho Falls, ID

    2009-09-08

    A robot platform includes perceptors, locomotors, and a system controller, which executes instructions for autonomously navigating a robot. The instructions repeat, on each iteration through an event timing loop, the acts of defining an event horizon based on the robot's current velocity, detecting a range to obstacles around the robot, testing for an event horizon intrusion by determining if any range to the obstacles is within the event horizon, and adjusting rotational and translational velocity of the robot accordingly. If the event horizon intrusion occurs, rotational velocity is modified by a proportion of the current rotational velocity reduced by a proportion of the range to the nearest obstacle and translational velocity is modified by a proportion of the range to the nearest obstacle. If no event horizon intrusion occurs, translational velocity is set as a ratio of a speed factor relative to a maximum speed.

  9. Modulation of cosmic microwave background polarization with a warm rapidly rotating half-wave plate on the Atacama B-Mode Search instrument.

    PubMed

    Kusaka, A; Essinger-Hileman, T; Appel, J W; Gallardo, P; Irwin, K D; Jarosik, N; Nolta, M R; Page, L A; Parker, L P; Raghunathan, S; Sievers, J L; Simon, S M; Staggs, S T; Visnjic, K

    2014-02-01

    We evaluate the modulation of cosmic microwave background polarization using a rapidly rotating, half-wave plate (HWP) on the Atacama B-Mode Search. After demodulating the time-ordered-data (TOD), we find a significant reduction of atmospheric fluctuations. The demodulated TOD is stable on time scales of 500-1000 s, corresponding to frequencies of 1-2 mHz. This facilitates recovery of cosmological information at large angular scales, which are typically available only from balloon-borne or satellite experiments. This technique also achieves a sensitive measurement of celestial polarization without differencing the TOD of paired detectors sensitive to two orthogonal linear polarizations. This is the first demonstration of the ability to remove atmospheric contamination at these levels from a ground-based platform using a rapidly rotating HWP.

  10. Development of an Adjustable board and a Rotational Board for Scaffold

    NASA Astrophysics Data System (ADS)

    Jang, Myunghoun

    2017-06-01

    Scaffold is widely used in high work-places inside and outside of a building construction site. It is inexpensive and is installed and dismantled easily. Although standards and ledgers of a steel tube and coupler scaffold are installed in a regular distance, the distances of transoms are not equal in some places. Sometimes a working platform or a board is absent in the corner of scaffold. This may cause safety accidents because a foothold is not stable on the transoms. An adjustable safety board and a rotational safety board are suggested in this paper. The adjustable board consists of two footholds. The small one is inserted into the large one. The rotational board covers not only right angle but also acute or obtuse angles. These safety boards for scaffold help to decrease safety accidents in construction sites.

  11. Detection Thresholds for Rotation and Translation Gains in 360° Video-Based Telepresence Systems.

    PubMed

    Zhang, Jingxin; Langbehn, Eike; Krupke, Dennis; Katzakis, Nicholas; Steinicke, Frank

    2018-04-01

    Telepresence systems have the potential to overcome limits and distance constraints of the real-world by enabling people to remotely visit and interact with each other. However, current telepresence systems usually lack natural ways of supporting interaction and exploration of remote environments (REs). In particular, single webcams for capturing the RE provide only a limited illusion of spatial presence, and movement control of mobile platforms in today's telepresence systems are often restricted to simple interaction devices. One of the main challenges of telepresence systems is to allow users to explore a RE in an immersive, intuitive and natural way, e.g., by real walking in the user's local environment (LE), and thus controlling motions of the robot platform in the RE. However, the LE in which the user's motions are tracked usually provides a much smaller interaction space than the RE. In this context, redirected walking (RDW) is a very suitable approach to solve this problem. However, so far there is no previous work, which explored if and how RDW can be used in video-based 360° telepresence systems. In this article, we conducted two psychophysical experiments in which we have quantified how much humans can be unknowingly redirected on virtual paths in the RE, which are different from the physical paths that they actually walk in the LE. Experiment 1 introduces a discrimination task between local and remote translations, and in Experiment 2 we analyzed the discrimination between local and remote rotations. In Experiment 1 participants performed straightforward translations in the LE that were mapped to straightforward translations in the RE shown as 360° videos, which were manipulated by different gains. Then, participants had to estimate if the remotely perceived translation was faster or slower than the actual physically performed translation. Similarly, in Experiment 2 participants performed rotations in the LE that were mapped to the virtual rotations in a 360° video-based RE to which we applied different gains. Again, participants had to estimate whether the remotely perceived rotation was smaller or larger than the actual physically performed rotation. Our results show that participants are not able to reliably discriminate the difference between physical motion in the LE and the virtual motion from the 360° video RE when virtual translations are down-scaled by 5.8% and up-scaled by 9.7%, and virtual rotations are about 12.3% less or 9.2% more than the corresponding physical rotations in the LE.

  12. Exploring the origin of the internal rotational barrier for molecules with one rotatable dihedral angle

    PubMed Central

    Liu, Shubin; Govind, Niranjan; Pedersen, Lee G.

    2008-01-01

    Continuing our recent endeavor, we systematically investigate in this work the origin of internal rotational barriers for small molecules using the new energy partition scheme proposed recently by one of the authors [S. B. Liu, J. Chem. Phys. 126, 244103 (2007)], where the total electronic energy is decomposed into three independent components, steric, electrostatic, and fermionic quantum. Specifically, we focus in this work on six carbon, nitrogen, and oxygen containing hydrides, CH3CH3, CH3NH2, CH3OH, NH2NH2, NH2OH, and H2O2, with only one rotatable dihedral angle ∠H–X–Y–H (X,Y=C,N,O). The relative contributions of the different energy components to the total energy difference as a function of the internal dihedral rotation will be considered. Both optimized-geometry (adiabatic) and fixed-geometry (vertical) differences are examined, as are the results from the conventional energy partition and natural bond orbital analysis. A wealth of strong linear relationships among the total energy difference and energy component differences for different systems have been observed but no universal relationship applicable to all systems for both cases has been discovered, indicating that even for simple systems such as these, there exists no omnipresent, unique interpretation on the nature and origin of the internal rotation barrier. Different energy components can be employed for different systems in the rationalization of the barrier height. Confirming that the two differences, adiabatic and vertical, are disparate in nature, we find that for the vertical case there is a unique linear relationship applicable to all the six molecules between the total energy difference and the sum of the kinetic and electrostatic energy differences. For the adiabatic case, it is the total potential energy difference that has been found to correlate well with the total energy difference except for ethane whose rotation barrier is dominated by the quantum effect. PMID:19044862

  13. Stabilization of gaze during circular locomotion in darkness. II. Contribution of velocity storage to compensatory eye and head nystagmus in the running monkey

    NASA Technical Reports Server (NTRS)

    Solomon, D.; Cohen, B.

    1992-01-01

    1. Yaw eye in head (Eh) and head on body velocities (Hb) were measured in two monkeys that ran around the perimeter of a circular platform in darkness. The platform was stationary or could be counterrotated to reduce body velocity in space (Bs) while increasing gait velocity on the platform (Bp). The animals were also rotated while seated in a primate chair at eccentric locations to provide linear and angular accelerations similar to those experienced while running. 2. Both animals had head and eye nystagmus while running in darkness during which slow phase gaze velocity on the body (Gb) partially compensated for body velocity in space (Bs). The eyes, driven by the vestibuloocular reflex (VOR), supplied high-frequency characteristics, bringing Gb up to compensatory levels at the beginning and end of the slow phases. The head provided substantial gaze compensation during the slow phases, probably through the vestibulocollic reflex (VCR). Synchronous eye and head quick phases moved gaze in the direction of running. Head movements occurred consistently only when animals were running. This indicates that active body and limb motion may be essential for inducing the head-eye gaze synergy. 3. Gaze compensation was good when running in both directions in one animal and in one direction in the other animal. The animals had long VOR time constants in these directions. The VOR time constant was short to one side in one animal, and it had poor gaze compensation in this direction. Postlocomotory nystagmus was weaker after running in directions with a long VOR time constant than when the animals were passively rotated in darkness. We infer that velocity storage in the vestibular system had been activated to produce continuous Eh and Hb during running and to counteract postrotatory afterresponses. 4. Continuous compensatory gaze nystagmus was not produced by passive eccentric rotation with the head stabilized or free. This indicates that an aspect of active locomotion, most likely somatosensory feedback, was responsible for activating velocity storage. 5. Nystagmus was compared when an animal ran in darkness and in light. the beat frequency of eye and head nystagmus was lower, and the quick phases were larger in darkness. The duration of head and eye quick phases covaried. Eye quick phases were larger when animals ran in darkness than when they were passively rotated. The maximum velocity and duration of eye quick phases were the same in both conditions. 6. The platform was counterrotated under one monkey in darkness while it ran in the direction of its long vestibular time constant.(ABSTRACT TRUNCATED AT 400 WORDS).

  14. Twin-Mirrored-Galvanometer Laser-Light-Sheet Generator

    NASA Technical Reports Server (NTRS)

    Rhodes, David B.; Franke, John M.; Jones, Stephen B.; Leighty, Bradley D.

    1991-01-01

    Multiple, rotating laser-light sheets generated to illuminate flows in wind tunnels. Designed and developed to provide flexibility and adaptability to wide range of applications. Design includes capability to control size and location of laser-light sheet in real time, to generate horizontal or vertical sheets, to sweep sheet repeatedly through volume, to generate multiple sheets with controllable separation, and to rotate single or multiple laser-light sheets. Includes electronic equipment and laser mounted on adjustable-height platform. Twin-mirrored galvanometer unit supported by tripod to reduce vibration. Other possible applications include use in construction industry to align beams of building. Artistic or display applications also possible.

  15. Kinesthetic control simulator. [for pilot training

    NASA Technical Reports Server (NTRS)

    Hill, P. R.; Thomas, D. F., Jr. (Inventor)

    1975-01-01

    A kinesthetic control simulator is reported that has a flat base upon which rests a support structure having a lower spherical surface for rotation on the base plate with columns which support a platform above the support structure at a desired location with respect to the center of curvature of the spherical surface. A handrail is at approximately the elevation of the hips of the operator above the platform with a ring attached to the support structure which may be used to limit the angle of tilt. Five degree freedom-of-motion can be obtained by utilizing an air pad structure for support of the control simulator.

  16. Comparison of aliphatic hydrocarbons, polycyclic aromatic hydrocarbons, polychlorinated biphenyls, polybrominated diphenylethers, and organochlorine pesticides in Pacific sanddab (Citharichthys sordidus) from offshore oil platforms and natural reefs along the California coast

    USGS Publications Warehouse

    Gale, Robert W.; Tanner, Michael J.; Love, Milton S.; Nishimoto, Mary M.; Schroeder, Donna M.

    2013-01-01

    Recently, the relative exposure of Pacific sanddab (Citharichthys sordidus) to polycyclic aromatic hydrocarbons (PAHs) at oil-production platforms was reported, indicating negligible exposure to PAHs and no discernible differences between exposures at platforms and nearby natural areas sites. In this report, the potential for chronic PAH exposure in fish is reported, by measurement of recalcitrant, higher molecular weight PAHs in tissues of fish previously investigated for PAH metabolites in bile. A total of 34 PAHs (20 PAHs, 11 alkylated PAHs, and 3 polycyclic aromatic thiophenes) were targeted. In addition, legacy contaminants—polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs),—and current contaminants, polybrominated diphenylethers (PBDEs) linked to endocrine disruption, were measured by gas chromatography with electron-capture or mass spectrometric detection, to form a more complete picture of the contaminant-related status of fishes at oil production platforms in the Southern California Bight. No hydrocarbon profiles or unresolved complex hydrocarbon background were found in fish from platforms and from natural areas, and concentrations of aliphatics were low less than 100 nanograms per gram (ng/g) per component]. Total-PAH concentrations in fish ranged from 15 to 37 ng/g at natural areas and from 8.7 to 22 ng/g at platforms. Profiles of PAHs were similar at all natural and platform sites, consisting mainly of naphthalene and methylnaphthalenes, phenanthrene, fluoranthene, and pyrene. Total-PCB concentrations (excluding non-ortho-chloro-substituted congeners) in fish were low, ranging from 7 to 22 ng/g at natural areas and from 10 to 35 ng/g at platforms. About 50 percent of the total-PCBs at all sites consisted of 11 congeners: 153 > 138/163/164 > 110 > 118 > 15 > 99 > 187 > 149 > 180. Most OCPs, except dichlorodiphenyltrichloroethane (DDT)-related compounds, were not detectable or were at concentrations of less than 1 ng/g in fish. p,p′-dichlorodiphenyltrichloroethane (p,p′-DDE) ranged from 5.6 to 33 ng/g at natural areas and from 17 to 76 ng/g at platforms, and comprised greater than 90 percent of the total-DDT concentrations at all sites. The only detectable PBDE congeners were PBDE-47 and PBDE-100, the total concentrations of which ranged from 0.4 to 1.8 ng/g at natural areas and from 0.5 to 3.0 ng/g at platforms. Total-PAH, -PCB, and -DDT concentrations were compared with other Southern California Bight studies involving shoreline mussel, (Mytilus Species, Kimbrough and others, 2008) and near shore sampling (Pacific sanddab, Schiff and Allen, 2000). At corresponding sites, only total-PCB concentrations agreed well with results from this study; total-DDT concentrations were generally much lower than concentrations documented in previous studies for samples collected nearer to shore by sewage treatment outfalls or 14 years earlier or closer in time to when DDT production was halted (1970). Natural areas and platforms in the Bight do not appear to be affected by harbor or urban pollution. Platforms were no more polluted than the nearby natural areas, with these locations exhibiting only low concentrations of PAHs, PCBs, DDTs, and other contaminants.

  17. Combining a Disturbance Observer with Triple-Loop Control Based on MEMS Accelerometers for Line-of-Sight Stabilization

    PubMed Central

    Huang, Yongmei; Deng, Chao; Ren, Wei; Wu, Qiongyan

    2017-01-01

    In the CCD-based fine tracking optical system (FTOS), the whole disturbance suppression ability (DSA) is the product of the inner loop and outer position loop. Traditionally, high sampling fiber-optic gyroscopes (FOGs) are added to the platform to stabilize the line-of-sight (LOS). However, because of the FOGs’ high cost and relatively big volume relative to the back narrow space of small rotating mirrors, we attempt in this work to utilize a cheaper and smaller micro-electro-mechanical system (MEMS) accelerometer to build the inner loop, replacing the FOG. Unfortunately, since accelerometers are susceptible to the low-frequency noise, according to the classical way of using accelerometers, the crucial low-frequency DSA of the system is insufficient. To solve this problem, in this paper, we propose an approach based on MEMS accelerometers combining disturbance observer (DOB) with triple-loop control (TLC) in which the composite velocity loop is built by acceleration integration and corrected by CCD. The DOB is firstly used to reform the platform, greatly improving the medium-frequency DSA. Then the composite velocity loop exchanges a part of medium-frequency performance for the low-frequency DSA. A detailed analysis and experiments verify the proposed method has a better DSA than the traditional way and could totally substitute FOG in the LOS stabilization. PMID:29149050

  18. How a disaster preparedness rotation helps teach the seven NAVMEC professional competencies: the Texas A&M University Experience.

    PubMed

    Bissett, Wesley T; Zoran, Debra L; Clendenin, Angela; Espitia, Noberto F; Moyer, William; Rogers, Kenita S

    2013-01-01

    Changing societal expectations provide new challenges and opportunities for the veterinary medical profession. These changing expectations and approaches to the education of veterinary students in the future are reflected in the North American Veterinary Medical Education Consortium's report "Roadmap for Veterinary Medical Education in the 21st Century: Responsive, Collaborative, Flexible." They are also reflected in the expectations of the populace, who no longer find it acceptable that animals are not included in both planning for and responding to natural or manmade disasters. In response to the changing needs of society and the veterinary profession, Texas A&M University College of Veterinary Medicine has developed a required rotation in the fourth-year curriculum on emergency planning and response. The unique requirements of emergency preparedness and response and the design of the rotation provide an ideal platform for providing this valued public service while simultaneously addressing the seven professional competencies outlined in the NAVMEC roadmap. This article describes an overview of the rotation and its content and identifies opportunities for students to practice these important professional competencies using the tools introduced in this new rotation.

  19. Design and experimental research of a novel inchworm type piezo-driven rotary actuator with the changeable clamping radius.

    PubMed

    Zhao, Hongwei; Fu, Lu; Ren, Luquan; Huang, Hu; Fan, Zunqiang; Li, Jianping; Qu, Han

    2013-01-01

    In this paper, a novel piezo-driven rotary actuator with the changeable clamping radius is developed based on the inchworm principle. This actuator mainly utilizes three piezoelectric actuators, a flexible gripper, a clamping block, and a rotor to achieve large stroke rotation with high resolution. The design process of the flexible gripper consisting of the driving unit and the clamping unit is described. Lever-type mechanisms were used to amplify the micro clamping displacements. The amplifying factor and parasitic displacement of the lever-type mechanism in the clamping unit was analyzed theoretically and experimentally. In order to investigate the rotation characteristics of the actuator, a series of experiments was carried out. Experimental results indicate that the actuator can rotate at a speed of 77,488 μrad/s with a driving frequency of 167 Hz. The rotation resolution and maximum load torque of the actuator are 0.25 μrad and 37 N mm, respectively. The gripper is movable along the z direction based on an elevating platform, and the clamping radius can change from 10.6 mm to 25 mm. Experimental results confirm that the actuator can achieve different rotation speeds by changing the clamping radius.

  20. An Investigation of Single- and Dual-Rotation Propellers at Positive and Negative Thrust, and in Combination with an NACA 1-series D-Type Cowling at Mach Numbers up to 0.84

    NASA Technical Reports Server (NTRS)

    Reynolds, Robert M; Samonds, Robert I; Walker, John H

    1957-01-01

    An investigation has been made to determine the aerodynamic characteristics of the NACA 4-(5)(05)-041 four-blade, single-relation propeller and the NACA 4-(5)(05)-037 six- and eight-blade, dual-rotation propellers in combination with various spinners and NACA d-type spinner-cowling combinations at Mach numbers up to 0.84. Propeller force characteristics, local velocity distributions in the propeller planes, inlet pressure recoveries, and static-pressure distributions on the cowling surfaces were measured for a wide range of blade angles, advance ratios, and inlet-velocity ratios. Included are data showing: (a) the effect of extended cylindrical spinners on the characteristics of the single-rotation propeller, (b) the effect of variation of the difference in blade angle setting between the front and rear components of the dual-rotation propellers, (c) the negative- and static-thrust characteristics of the propellers with 1 series spinners, and (d) the effects of ideal- and platform-type propeller-spinner junctures on the pressure-recovery characteristics of the single-rotation propeller-spinner-cowling combination.

  1. Can walking motions improve visually induced rotational self-motion illusions in virtual reality?

    PubMed

    Riecke, Bernhard E; Freiberg, Jacob B; Grechkin, Timofey Y

    2015-02-04

    Illusions of self-motion (vection) can provide compelling sensations of moving through virtual environments without the need for complex motion simulators or large tracked physical walking spaces. Here we explore the interaction between biomechanical cues (stepping along a rotating circular treadmill) and visual cues (viewing simulated self-rotation) for providing stationary users a compelling sensation of rotational self-motion (circular vection). When tested individually, biomechanical and visual cues were similarly effective in eliciting self-motion illusions. However, in combination they yielded significantly more intense self-motion illusions. These findings provide the first compelling evidence that walking motions can be used to significantly enhance visually induced rotational self-motion perception in virtual environments (and vice versa) without having to provide for physical self-motion or motion platforms. This is noteworthy, as linear treadmills have been found to actually impair visually induced translational self-motion perception (Ash, Palmisano, Apthorp, & Allison, 2013). Given the predominant focus on linear walking interfaces for virtual-reality locomotion, our findings suggest that investigating circular and curvilinear walking interfaces offers a promising direction for future research and development and can help to enhance self-motion illusions, presence and immersion in virtual-reality systems. © 2015 ARVO.

  2. An MR-compatible gyroscope-based arm movement tracking system.

    PubMed

    Shirinbayan, S Iman; Rieger, Jochem W

    2017-03-15

    Functional magnetic resonance imaging is well suited to link neural population activation with movement parameters of complex natural arm movements. However, currently existing MR-compatible arm tracking devices are not constructed to measure arm joint movement parameters of unrestricted movements. Therefore, to date most research focuses on simple arm movements or includes very little knowledge about the actual movement kinematics. We developed a low cost gyroscope-based arm movement tracking system (GAMTS) that features MR-compatibility. The system consists of dual-axis analogue gyroscopes that measure rotations of upper and lower arm joints. After MR artifact reduction, the rotation angles of the individual arm joints are calculated and used to animate a realistic arm model that is implemented in the OpenSim platform. The OpenSim platform can then provide the kinematics of any point on the arm model. In order to demonstrate the capabilities of the system, we first assessed the quality of reconstructed wrist movements in a low-noise environment where typical MR-related problems are absent and finally, we validated the reconstruction in the MR environment. The system provides the kinematics of the whole arm when natural unrestricted arm movements are performed inside the MR-scanner. The GAMTS is reliably capable of reconstructing the kinematics of trajectories and the reconstruction error is small in comparison with the movement induced variation of speed, displacement, and rotation. Moreover, the system can be used to probe brain areas for their correlation with movement kinematics. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Glenohumeral internal rotation deficit in throwing athletes: current perspectives

    PubMed Central

    Rose, Michael B; Noonan, Thomas

    2018-01-01

    Glenohumeral internal rotation deficit (GIRD) is an adaptive process in which the throwing shoulder experiences a loss of internal rotation (IR). GIRD has most commonly been defined by a loss of >20° of IR compared to the contralateral shoulder. Total rotational motion of the shoulder is the sum of internal and external rotation and may be more important than the absolute value of IR loss. Pathologic GIRD has been defined as a loss of IR combined with a loss of total rotational motion. The leading pathologic process in GIRD is posterior capsular and rotator-cuff tightness, due to the repetitive cocking that occurs with the overhead throwing motion. GIRD has been associated with numerous pathologic conditions, including posterior superior labral tears, partial articular-sided rotator-cuff tears, and superior labral anterior-to-posterior tears. The mainstay of treatment for patients with GIRD is posterior capsular stretching and strengthening to improve scapular mechanics. In patients who fail nonoperative therapy, shoulder arthroscopy can be performed. Arthroscopic surgery in the high-level throwing athlete should be to restore them to their functional baseline with the minimum amount of intervention possible. PMID:29593438

  4. Geostationary platform systems concepts definition study. Volume 2: Technical, book 1

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The initial selection and definition of operational geostationary platform concepts is discussed. Candidate geostationary platform missions and payloads were identified from COMSAT, Aerospace, and NASA studies. These missions and payloads were cataloged; classified with to communications, military, or scientific uses; screened for application and compatibility with geostationary platforms; and analyzed to identify platform requirements. Two platform locations were then selected (Western Hemisphere - 110 deg W, and Atlantic - 15 deg W), and payloads allocated based on nominal and high traffic models. Trade studies were performed leading to recommendation of selected concepts. Of 30 Orbit Transfer Vehicle (0TV) configuration and operating mode options identified, 18 viable candidates compatible with the operational geostationary platform missions were selected for analysis. Each was considered using four platform operational modes - 8 or 16 year life, and serviced or nonserviced, providing a total of 72 OTV/platform-mode options. For final trade study concept selection, a cost program was developed considering payload and platform costs and weight; transportation unit and total costs for the shuttle and OTV; and operational costs such as assembly or construction time, mating time, and loiter time. Servicing costs were added for final analysis and recommended selection.

  5. Age-related changes in posture response under a continuous and unexpected perturbation.

    PubMed

    Tsai, Yi-Ching; Hsieh, Lin-Fen; Yang, Saiwei

    2014-01-22

    Aging is a critical factor to influence the functional performance during daily life. Without an appropriate posture control response when experiencing an unexpected external perturbation, fall may occur. A novel six-degree-of freedom platform with motion control protocol was designed to provide a real-life simulation of unexpected disturbance in order to discriminate the age-related changes of the balance control and the recovery ability. Twenty older adults and 20 healthy young adults participated in the study. The subjects stood barefoot on the novel movable platform, data of the center of mass (COM) excursion, joint rotation angle and electromyography (EMG) were recorded and compared. The results showed that the older adults had similar patterns of joint movement and COM excursion as the young adults during the balance reactive-recovery. However, larger proximal joint rotation in elderly group induced larger COM sway envelop and therefore loss of the compensatory strategy of posture recovery. The old adults also presented a lower muscle power. In order to keep an adequate joint stability preventing from falling, the EMG activity was increased, but the asymmetric pattern might be the key reason of unstable postural response. This novel design of moveable platform and test protocol comprised the computerized dynamic posturography (CDP) demonstrate its value to assess the possible sensory, motor, and central adaptive impairments to balance control and could be the training tool for posture inability person. © 2013 Elsevier Ltd. All rights reserved.

  6. Influence of Component Rotation in Total Knee Arthroplasty on Tibiofemoral Kinematics-A Cadaveric Investigation.

    PubMed

    Maderbacher, Guenther; Keshmiri, Armin; Springorum, Hans R; Maderbacher, Hermann; Grifka, Joachim; Baier, Clemens

    2017-09-01

    Physiological tibiofemoral kinematics have been shown to be important for good knee function after total knee arthroplasty (TKA). The purpose of the present study was to investigate the influence of component rotation on tibiofemoral kinematics during knee flexion. We asked which axial component alignment best reconstructs physiological tibiofemoral kinematics and which combinations should be avoided. Ten healthy cadaveric knees were examined. By means of a navigational device, tibiofemoral kinematics between 0° and 90° of flexion were assessed before and after TKA using the following different rotational component alignment: femoral components: ligament balanced, 6° internal, 3° external rotation, and 6° external rotation in relation to the posterior condylar line; tibial components: self-adapted, 6° internal rotation, and 6° external rotation. Physiological tibiofemoral kinematics could be partly reconstructed by TKA. Ligament-balanced femoral rotation and 6° femoral external rotation both in combination with 6° tibial component external rotation, and 3° femoral external rotation in combination with 6° tibial component internal rotation or self-aligning tibial component were able to restore tibial longitudinal rotation. Largest kinematical differences were found for the combination femoral component internal and tibial component external rotations. From a kinematic-based view, surgeons should avoid internal rotation of femoral components. However, even often recommended combinations of rotational component alignment (3° femoral external and tibial external rotation) significantly change tibiofemoral kinematics. Self-aligning tibial components solely restored tibiofemoral kinematics with the combination of 3° femoral component of external rotation. For the future, navigational devices might help to axially align components to restore patient-specific and natural tibiofemoral kinematics. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Relationship between extrinsic factors and the acromio-humeral distance.

    PubMed

    Mackenzie, Tanya Anne; Herrington, Lee; Funk, Lenard; Horsley, Ian; Cools, Ann

    2016-06-01

    Maintenance of the subacromial space is important in impingement syndromes. Research exploring the correlation between biomechanical factors and the subacromial space would be beneficial. To establish if relationship exists between the independent variables of scapular rotation, shoulder internal rotation, shoulder external rotation, total arc of shoulder rotation, pectoralis minor length, thoracic curve, and shoulder activity level with the dependant variables: AHD in neutral, AHD in 60° arm abduction, and percentage reduction in AHD. Controlled laboratory study. Data from 72 male control shoulders (24.28years STD 6.81 years) and 186 elite sportsmen's shoulders (25.19 STD 5.17 years) were included in the analysis. The independent variables were quantified and real time ultrasound was used to measure the dependant variable acromio-humeral distance. Shoulder internal rotation and pectoralis minor length, explained 8% and 6% respectively of variance in acromio-humeral distance in neutral. Pectoralis minor length accounted for 4% of variance in 60° arm abduction. Total arc of rotation, shoulder external rotation range, and shoulder activity levels explained 9%, 15%, and 16%-29% of variance respectively in percentage reduction in acromio-humeral distance during arm abduction to 60°. Pectorals minor length, shoulder rotation ranges, total arc of shoulder rotation, and shoulder activity levels were found to have weak to moderate relationships with acromio-humeral distance. Existence and strength of relationship was population specific and dependent on arm position. Relationships only accounted for small variances in AHD indicating that in addition to these factors there are other factors involved in determining AHD. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Dynamic control of a moving platform using the CAREN system to optimize walking in virtual reality environments.

    PubMed

    Makssoud, Hassan El; Richards, Carol L; Comeau, François

    2009-01-01

    Virtual reality (VR) technology offers the opportunity to expose patients to complex physical environments without physical danger and thus provides a wide range of opportunities for locomotor training or the study of human postural and walking behavior. A VR-based locomotor training system has been developed for gait rehabilitation post-stroke. A clinical study has shown that persons after stroke are able to adapt and benefit from this novel system wherein they walk into virtual environments (VEs) on a self-paced treadmill mounted on a platform with 6 degrees of freedom. This platform is programmed to mimic changes in the terrain encountered in the VEs. While engaging in these VEs, excessive trunk movements and speed alterations have been observed, especially during the pitch perturbations accompanying uphill or downhill terrain changes. An in-depth study of the subject's behavior in relation to the platform movements revealed that the platform rotational axes need to be modified, as previously shown by Barton et al, and in addition did not consider the subject's position on the treadmill. The aim of this study was to determine an optimal solution to simulate walking in real life when engaging in VEs.

  9. The neurochemical and neuropharmacological basis of motion sickness

    NASA Technical Reports Server (NTRS)

    Walker, C. A.

    1990-01-01

    An apparatus suitable for producing motion sickness in laboratory animals and constructed at the university is herein described. The apparatus is a modified version of that previously described by Fox and Daunton. It consists of a 66-inch steel arm anchored at the center to a wooden platform and attached to a motor that makes the arm move in a see-saw fashion. At each end of the steel arm is mounted an aluminum disc that can be rotated by a motorized device. Detachable cages are mounted on each disc for animal holding. The animal can then be exposed to rotational motion by rotation of the aluminum disc, or to see-saw motion simultaneously (Cross-coupled). The apparatus is presently being used in our laboratory to study the neuropharmacological basis of motion sickness in the rat. The device can be adapted for use with other animal species by modifying the cage mounted on the aluminum discs.

  10. Motion-induced eddy current thermography for high-speed inspection

    NASA Astrophysics Data System (ADS)

    Wu, Jianbo; Li, Kongjing; Tian, Guiyun; Zhu, Junzhen; Gao, Yunlai; Tang, Chaoqing; Chen, Xiaotian

    2017-08-01

    This letter proposes a novel motion-induced eddy current based thermography (MIECT) for high-speed inspection. In contrast to conventional eddy current thermography (ECT) based on a time-varying magnetic field created by an AC coil, the motion-induced eddy current is induced by the relative motion between magnetic field and inspected objects. A rotating magnetic field created by three-phase windings is used to investigate the heating principle and feasibility of the proposed method. Firstly, based on Faraday's law the distribution of MIEC is investigated, which is then validated by numerical simulation. Further, experimental studies are conducted to validate the proposed method by creating rotating magnetic fields at different speeds from 600 rpm to 6000 rpm, and it is verified that rotating speed will increase MIEC intensity and thereafter improve the heating efficiency. The conclusion can be preliminarily drawn that the proposed MIECT is a platform suitable for high-speed inspection.

  11. Rotational homogeneity in graphene grown on Au(111)

    NASA Astrophysics Data System (ADS)

    Wofford, Joseph; Starodub, Elena; Walter, Andrew; Nie, Shu; Bostwick, Aaron; Bartelt, Norman; Thürmer, Konrad; Rotenberg, Eli; McCarty, Kevin; Dubon, Oscar

    2012-02-01

    The set of properties offered by the (111) surface of gold makes it intriguing as a platform on which to study the fundamental processes that underpin graphene growth on metals. Among these are the low carbon solubility and an interaction strength with graphene that is predicted to be smaller than most transition metals. We have investigated this synthesis process using low-energy electron microscopy and diffraction to monitor the sample surface in real time, and found that the resulting graphene film possesses a remarkable degree of rotational homogeneity. The dominant orientation of the graphene is aligned with the Au lattice, with a small minority rotated by 30 degrees. The origins of this in-plane structuring are puzzling because angularly resolved photo-emission spectroscopy and scanning tunneling microscopy experiments both suggest only a relatively small interaction between the two materials. Finally, the implications of these findings for the growth of high structural-quality graphene films are discussed.

  12. Controllable High-Speed Rotation of Nanowires

    NASA Astrophysics Data System (ADS)

    Fan, D. L.; Zhu, F. Q.; Cammarata, R. C.; Chien, C. L.

    2005-06-01

    We report a versatile method for executing controllable high-speed rotation of nanowires by ac voltages applied to multiple electrodes. The rotation of the nanowires can be instantly switched on or off with precisely controlled rotation speed (to at least 1800 rpm), definite chirality, and total angle of rotation. We have determined the torque due to the fluidic drag force on nanowire of different lengths. We also demonstrate a micromotor using a rotating nanowire driving a dust particle into circular motion. This method has been used to rotate magnetic and nonmagnetic nanowires as well as carbon nanotubes.

  13. A solar activity monitoring platform for SCADM

    NASA Technical Reports Server (NTRS)

    Kissell, K. E.; Ratcliff, D. D.

    1980-01-01

    The adaptation of proven space probe technology is proposed as a means of providing a solar activity monitoring platform which could be injected behind the Earth's orbital position to give 3 to 6 days advanced coverage of the solar phenomenon on the backside hemisphere before it rotates into view and affects terrestrial activities. The probe would provide some three dimensional discrimination within the ecliptic latitude. This relatively simple off-Earth probe could provide very high quality data to support the SCADM program, by transmitting both high resolution video data of the solar surface and such measurements of solar activity as particle, X-ray, ultraviolet, and radio emission fluxes. Topics covered include the orbit; constraints on the spacecraft; subsystems and their embodiments; optical imaging sensors and their operation; and the radiation-pressure attitude control system are described. The platform would be capable of mapping active regions on an hourly basis with one arc-second resolution.

  14. 3D range-gated super-resolution imaging based on stereo matching for moving platforms and targets

    NASA Astrophysics Data System (ADS)

    Sun, Liang; Wang, Xinwei; Zhou, Yan

    2017-11-01

    3D range-gated superresolution imaging is a novel 3D reconstruction technique for target detection and recognition with good real-time performance. However, for moving targets or platforms such as airborne, shipborne, remote operated vehicle and autonomous vehicle, 3D reconstruction has a large error or failure. In order to overcome this drawback, we propose a method of stereo matching for 3D range-gated superresolution reconstruction algorithm. In experiment, the target is a doll of Mario with a height of 38cm at the location of 34m, and we obtain two successive frame images of the Mario. To confirm our method is effective, we transform the original images with translation, rotation, scale and perspective, respectively. The experimental result shows that our method has a good result of 3D reconstruction for moving targets or platforms.

  15. Assessment of the midflexion rotational laxity in posterior-stabilized total knee arthroplasty.

    PubMed

    Hino, Kazunori; Kutsuna, Tatsuhiko; Oonishi, Yoshio; Watamori, Kunihiko; Kiyomatsu, Hiroshi; Iseki, Yasutake; Watanabe, Seiji; Ishimaru, Yasumitsu; Miura, Hiromasa

    2017-11-01

    To evaluate changes in midflexion rotational laxity before and after posterior-stabilized (PS)-total knee arthroplasty (TKA). Twenty-nine knees that underwent PS-TKA were evaluated. Manual mild passive rotational stress was applied to the knees, and the internal-external rotational angle was measured automatically by a navigation system at 30°, 45°, 60°, and 90° of knee flexion. The post-operative internal rotational laxity was statistically significantly increased compared to the preoperative level at 30°, 45°, 60°, and 90° of flexion. The post-operative external rotational laxity was statistically significantly decreased compared to the preoperative level at 45° and 60° of flexion. The post-operative internal-external rotational laxity was statistically significantly increased compared to the preoperative level only at 30° of flexion. The preoperative and post-operative rotational laxity showed a significant correlation at 30°, 45°, 60°, and 90° of flexion. Internal-external rotational laxity increases at the initial flexion range due to resection of both the anterior or posterior cruciate ligaments and retention of the collateral ligaments in PS-TKA. Preoperative and post-operative rotational laxity indicated a significant correlation at the midflexion range. This study showed that a large preoperative rotational laxity increased the risk of a large post-operative laxity, especially at the initial flexion range in PS-TKA. III.

  16. Ab initio study of charge transfer in B2+ low-energy collisions with atomic hydrogen

    NASA Astrophysics Data System (ADS)

    Turner, A. R.; Cooper, D. L.; Wang, J. G.; Stancil, P. C.

    2003-07-01

    Charge transfer processes due to collisions of ground state B2+(2s 2S) ions with atomic hydrogen are investigated using the quantum-mechanical molecular-orbital close-coupling (MOCC) method. The MOCC calculations utilize ab initio adiabatic potentials and nonadiabatic radial and rotational coupling matrix elements obtained with the spin-coupled valence-bond approach. Total and state-selective cross sections and rate coefficients are presented. Comparison with the existing experiments shows our results to be in good agreement. When E<80 eV/u, the differences between the current total MOCC cross sections with and without rotational coupling are small (<3%). Rotational coupling becomes more important with increasing energy: for collision energies E>400 eV/u, inclusion of rotational coupling increases the total cross section by 50% 80%, improving the agreement between the current calculations and experiments. For state-selective cross sections, rotational coupling induces mixing between different symmetries; however, its effect, especially at low collision energies, is not as important as had been suggested in previous work.

  17. Rapid, Sensitive Detection of Botulinum Toxin on a Flexible Microfluidics Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warner, Marvin G.; Dockendorff, Brian P.; Feldhaus, Michael J.

    2004-10-30

    In this paper we will describe how high affinity reagents and a sensor configuration enabling rapid mass transport can be combined for rapid, sensitive biodetection. The system that we have developed includes a renewable surface immunoassay, which involves on-column detection of a fluorescently labeled secondary antibody in a sandwich immunoassay. Yeast display and directed molecular evolution were used to create high affinity antibodies to the botulinum toxin heavy chain receptor binding domain, AR1 and 3D12. A rotating rod renewable surface microcolumn was used to form a microliter-sized column containing beads functionalized with the capture antibody (AR1). The column was perfusedmore » with sample, wash solutions, and a fluorescently labeled secondary antibody (3D12) while the on-column fluorescence was monitored. Detection was accomplished in less than 5 minutes, with a total processing time of about 10 minutes. On-column detection of botulinum toxin was more sensitive and much faster than flow cytometry analysis on microbeads using the same reagents.« less

  18. A comparative analysis between fixed bearing total knee arthroplasty (PFC Sigma) and rotating platform total knee arthroplasty (PFC-RP) with minimum 3-year follow-up.

    PubMed

    Jawed, Akram; Kumar, Vijay; Malhotra, R; Yadav, C S; Bhan, S

    2012-06-01

    Since the introduction of mobile bearing total knee designs nearly 30 years back, many studies have been done to evaluate its long-term result. Comparison with fixed bearing designs has been done in the past, but the studies were confounded by variables such as disease, surgeon, bone quality, pain tolerance, etc. We attempt to eliminate these variables in this study. A total of 50 patients who had bilateral arthritis of the knee with similar deformity and pre-operative range of motion on both sides agreed to have one knee replaced with mobile bearing total knee design (PFC-RP) and the other with a fixed bearing design (PFC Sigma) were prospectively evaluated. Comparative analysis of both the designs was done at a mean follow-up of 40 months, minimizing patient, surgeon and observer related bias. Clinical and radiographic outcome, survival and complication rates were compared. At a mean follow-up of 40 months (range 36-47 months), no benefit of mobile bearing (PFC-RP) over fixed bearing design (PFC Sigma) could be demonstrated with respect to Knee Society scores, pain scores, range of flexion, subject preference or patello-femoral complication rates. Radiographs showed no difference in prosthetic alignment. No patient required a revision surgery till last follow-up. Our study demonstrated no advantage of the mobile-bearing arthroplasty over fixed bearing arthroplasty with regard to clinical results at short-term follow-up. However, longer follow-up is necessary to confirm whether these results are sustained.

  19. Seismogenic rotational slumps and translational glides in pelagic deep-water carbonates. Upper Tithonian-Berriasian of Southern Tethyan margin (W Sicily, Italy)

    NASA Astrophysics Data System (ADS)

    Basilone, Luca

    2017-07-01

    Soft-sediment deformation structures (SSDSs), which reflect sediment mobilization processes, are helpful to identify punctual events of paleoenvironmental stresses. In the upper Tithonian-Berriasian calpionellid pelagic limestone of the Lattimusa Fm. outcropping in the Barracù section (W Sicily), paleoenvironmental restoration reveals the occurrence of a deep-water flat basin, characterised by undeformed planar bedding, laterally passing to a gentle slope where the deformed horizons alternate with undeformed beds. Here, two types of gravity slides have been differentiated on the basis of different kinds of SSDSs, brittle deformation, involved lithofacies, geometry and morphology. Type 1 slump sheets, involving marl-limestone couplets, are characterised by chaotic stratification, truncated beds, recumbent folds, tension gashes, clastic dikes and small-scale listric normal faults and thrusts. They moved downslope as a rotational slump, displaying the typical wedge-shaped morphology, becoming thicker toe-wards. Type 2 slump sheets, involving bed packages of lime mudstone, are characterised by arcuate slump scars developing downwards as listric normal faults, associated with rotational beds and bulging. Displaying tabular geometries, they moved coherently along an overall bedding parallel detachment surface as a translational glide characterised by sediment creep. Regional geology indicates that the basin (Sicanian), bordered by a stepped carbonate platform, was affected by synsedimentary tectonics throughout the Mesozoic. The synsedimentary extensional tectonics that affect the Upper Triassic-Jurassic deposits with steeped normal faults, causing tilt-block and instability of the seafloor through fluidization processes, triggered the rotational slumps of the lower portion of the section. Seismic shocks, induced by outside sector tectonics, like those recorded in the adjacent Busambra stepped carbonate platform margin, triggered the rotational slumps that are not related to local-scale faults. To explain the translational glides of the upper portion of the section, the aforementioned outside sector earthquakes produced instability of the sea-floor through thixotropy of marls. In this case, the driving forces (i.e., gravitational) were favoured by the uplifting trend that is well recorded in the Southern Tethyan continental margin. We suggest that the various early deformations represent rotational slump and sediment creep that may be characteristic for slump structures in pelagic carbonates, depending on the involved lithologies (i.e., paleoenvironmental setting) and the intensity/distance of the trigger mechanism (i.e., earthquake epicentre).

  20. Biomechanical comparison of reverse total shoulder arthroplasty systems in soft tissue-constrained shoulders.

    PubMed

    Henninger, Heath B; King, Frank K; Tashjian, Robert Z; Burks, Robert T

    2014-05-01

    Numerous studies have examined the biomechanics of isolated variables in reverse total shoulder arthroplasty. This study directly compared the composite performance of two reverse total shoulder arthroplasty systems; each system was designed around either a medialized or a lateralized glenohumeral center of rotation. Seven pairs of shoulders were tested on a biomechanical simulator. Center of rotation, position of the humerus, passive and active range of motion, and force to abduct the arm were quantified. Native arms were tested, implanted with a Tornier Aequalis or DJO Surgical Reverse Shoulder Prosthesis (RSP), and then retested. Differences from the native state were then documented. Both systems shifted the center of rotation medially and inferiorly relative to native. Medial shifts were greater in the Aequalis implant (P < .037). All humeri shifted inferior compared with native but moved medially with the Aequalis (P < .001). Peak passive abduction, internal rotation, and external rotation did not differ between systems (P > .05). Both reverse total shoulder arthroplasty systems exhibited adduction deficits, but the RSP implant deficit was smaller (P = .046 between implants). Both systems reduced forces to abduct the arm compared with native, although the Aequalis required more force to initiate motion from the resting position (P = .022). Given the differences in system designs and configurations, outcome variables were generally comparable. The RSP implant allowed slightly more adduction, had a more lateralized humeral position, and required less force to initiate elevation. These factors may play roles in limiting scapular notching, improving active external rotation by normalizing the residual rotator cuff length, and limiting excessive stress on the deltoid. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  1. Vortex Generators in a Streamline-Traced, External-Compression Supersonic Inlet

    NASA Technical Reports Server (NTRS)

    Baydar, Ezgihan; Lu, Frank K.; Slater, John W.; Trefny, Charles J.

    2017-01-01

    Vortex generators within a streamline-traced, external-compression supersonic inlet for Mach 1.66 were investigated to determine their ability to increase total pressure recovery and reduce total pressure distortion. The vortex generators studied were rectangular vanes arranged in counter-rotating and co-rotating arrays. The vane geometric factors of interest included height, length, spacing, angle-of-incidence, and positions upstream and downstream of the inlet terminal shock. The flow through the inlet was simulated numerically through the solution of the steady-state, Reynolds-averaged Navier-Stokes equations on multi-block, structured grids using the Wind-US flow solver. The vanes were simulated using a vortex generator model. The inlet performance was characterized by the inlet total pressure recovery and the radial and circumferential total pressure distortion indices at the engine face. Design of experiments and statistical analysis methods were applied to quantify the effect of the geometric factors of the vanes and search for optimal vane arrays. Co-rotating vane arrays with negative angles-of-incidence positioned on the supersonic diffuser were effective in sweeping low-momentum flow from the top toward the sides of the subsonic diffuser. This distributed the low-momentum flow more evenly about the circumference of the subsonic diffuser and reduced distortion. Co-rotating vane arrays with negative angles-of-incidence or counter-rotating vane arrays positioned downstream of the terminal shock were effective in mixing higher-momentum flow with lower-momentum flow to increase recovery and decrease distortion. A strategy of combining a co-rotating vane array on the supersonic diffuser with a counter-rotating vane array on the subsonic diffuser was effective in increasing recovery and reducing distortion.

  2. Automated system for the calibration of magnetometers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petrucha, Vojtech; Kaspar, Petr; Ripka, Pavel

    2009-04-01

    A completely nonmagnetic calibration platform has been developed and constructed at DTU Space (Technical University of Denmark). It is intended for on-site scalar calibration of high-precise fluxgate magnetometers. An enhanced version of the same platform is being built at the Czech Technical University. There are three axes of rotation in this design (compared to two axes in the previous version). The addition of the third axis allows us to calibrate more complex devices. An electronic compass based on a vector fluxgate magnetometer and micro electro mechanical systems (MEMS) accelerometer is one example. The new platform can also be used tomore » evaluate the parameters of the compass in all possible variations in azimuth, pitch, and roll. The system is based on piezoelectric motors, which are placed on a platform made of aluminum, brass, plastic, and glass. Position sensing is accomplished through custom-made optical incremental sensors. The system is controlled by a microcontroller, which executes commands from a computer. The properties of the system as well as calibration and measurement results will be presented.« less

  3. Virtual Distances Methodology as Verification Technique for AACMMs with a Capacitive Sensor Based Indexed Metrology Platform

    PubMed Central

    Acero, Raquel; Santolaria, Jorge; Brau, Agustin; Pueo, Marcos

    2016-01-01

    This paper presents a new verification procedure for articulated arm coordinate measuring machines (AACMMs) together with a capacitive sensor-based indexed metrology platform (IMP) based on the generation of virtual reference distances. The novelty of this procedure lays on the possibility of creating virtual points, virtual gauges and virtual distances through the indexed metrology platform’s mathematical model taking as a reference the measurements of a ball bar gauge located in a fixed position of the instrument’s working volume. The measurements are carried out with the AACMM assembled on the IMP from the six rotating positions of the platform. In this way, an unlimited number and types of reference distances could be created without the need of using a physical gauge, therefore optimizing the testing time, the number of gauge positions and the space needed in the calibration and verification procedures. Four evaluation methods are presented to assess the volumetric performance of the AACMM. The results obtained proved the suitability of the virtual distances methodology as an alternative procedure for verification of AACMMs using the indexed metrology platform. PMID:27869722

  4. Mode Tracker for Mode-Hop-Free Operation of a Laser

    NASA Technical Reports Server (NTRS)

    Wysocki, Gerard; Tittel, Frank K.; Curl, Robert F.

    2010-01-01

    A mode-tracking system that includes a mode-controlling subsystem has been incorporated into an external-cavity (EC) quantum cascade laser that operates in a mid-infrared wavelength range. The mode-tracking system makes it possible to perform mode-hop-free wavelength scans, as needed for high-resolution spectroscopy and detection of trace gases. The laser includes a gain chip, a beam-collimating lens, and a diffraction grating. The grating is mounted on a platform, the position of which can be varied to effect independent control of the EC length and the grating angle. The position actuators include a piezoelectric stage for translation control and a motorized stage for coarse rotation control equipped with a piezoelectric actuator for fine rotation control. Together, these actuators enable control of the EC length over a range of about 90 m with a resolution of 0.9 nm, and control of the grating angle over a coarse-tuning range of +/-6.3deg and a fine-tuning range of +/-520 microrad with a resolution of 10 nrad. A mirror mounted on the platform with the grating assures always the same direction of the output laser beam.

  5. Contribution of self-motion perception to acoustic target localization.

    PubMed

    Pettorossi, V E; Brosch, M; Panichi, R; Botti, F; Grassi, S; Troiani, D

    2005-05-01

    The findings of this study suggest that acoustic spatial perception during head movement is achieved by the vestibular system, which is responsible for the correct dynamic of acoustic target pursuit. The ability to localize sounds in space during whole-body rotation relies on the auditory localization system, which recognizes the position of sound in a head-related frame, and on the sensory systems, namely the vestibular system, which perceive head and body movement. The aim of this study was to analyse the contribution of head motion cues to the spatial representation of acoustic targets in humans. Healthy subjects standing on a rotating platform in the dark were asked to pursue with a laser pointer an acoustic target which was horizontally rotated while the body was kept stationary or maintained stationary while the whole body was rotated. The contribution of head motion to the spatial acoustic representation could be inferred by comparing the gains and phases of the pursuit in the two experimental conditions when the frequency was varied. During acoustic target rotation there was a reduction in the gain and an increase in the phase lag, while during whole-body rotations the gain tended to increase and the phase remained constant. The different contributions of the vestibular and acoustic systems were confirmed by analysing the acoustic pursuit during asymmetric body rotation. In this particular condition, in which self-motion perception gradually diminished, an increasing delay in target pursuit was observed.

  6. Shoulder-Rotator Strength, Range of Motion, and Acromiohumeral Distance in Asymptomatic Adolescent Volleyball Attackers

    PubMed Central

    Harput, Gulcan; Guney, Hande; Toprak, Ugur; Kaya, Tunca; Colakoglu, Fatma Filiz; Baltaci, Gul

    2016-01-01

    Context: Sport-specific adaptations at the glenohumeral joint could occur in adolescent athletes because they start participating in high-performance sports in early childhood. Objective: To investigate shoulder-rotator strength, internal-rotation (IR) and external-rotation (ER) range of motion (ROM), and acromiohumeral distance (AHD) in asymptomatic adolescent volleyball attackers to determine if they have risk factors for injury. Design: Cross-sectional study. Setting: University laboratory. Participants: Thirty-nine adolescent high school-aged volleyball attackers (22 boys, 17 girls; age = 16.0 ± 1.4 years, height = 179.2 ± 9.0 cm, mass = 67.1 ± 10.9 kg, body mass index = 20.7 ± 2.6 kg/m2). Main Outcome Measure(s): Shoulder IR and ER ROM, total-rotation ROM, glenohumeral IR deficit, AHD, and concentric and eccentric strength of the shoulder internal and external rotators were tested bilaterally. Results: External-rotation ROM was greater (t38 = 4.92, P < .001), but IR ROM (t38 = −8.61, P < .001) and total ROM (t38 = −3.55, P = .01) were less in the dominant shoulder, and 15 athletes had a glenohumeral IR deficit (IR ROM loss > 18°). We observed greater concentric internal-rotator (t38 = 2.89, P = .006) and eccentric external-rotator (t38 = 2.65, P = .01) strength in the dominant than in the nondominant shoulder. The AHD was less in the dominant shoulder (t38 = −3.60, P < .001). Conclusions: Adolescent volleyball attackers demonstrated decreased IR ROM, total ROM, and AHD and increased ER ROM in their dominant shoulder. Therefore, routine screening of adolescent athletes and designing training programs for hazardous adaptive changes could be important in preventing shoulder injuries. PMID:27813683

  7. Shoulder-Rotator Strength, Range of Motion, and Acromiohumeral Distance in Asymptomatic Adolescent Volleyball Attackers.

    PubMed

    Harput, Gulcan; Guney, Hande; Toprak, Ugur; Kaya, Tunca; Colakoglu, Fatma Filiz; Baltaci, Gul

    2016-09-01

    Sport-specific adaptations at the glenohumeral joint could occur in adolescent athletes because they start participating in high-performance sports in early childhood. To investigate shoulder-rotator strength, internal-rotation (IR) and external-rotation (ER) range of motion (ROM), and acromiohumeral distance (AHD) in asymptomatic adolescent volleyball attackers to determine if they have risk factors for injury. Cross-sectional study. University laboratory. Thirty-nine adolescent high school-aged volleyball attackers (22 boys, 17 girls; age = 16.0 ± 1.4 years, height = 179.2 ± 9.0 cm, mass = 67.1 ± 10.9 kg, body mass index = 20.7 ± 2.6 kg/m 2 ). Shoulder IR and ER ROM, total-rotation ROM, glenohumeral IR deficit, AHD, and concentric and eccentric strength of the shoulder internal and external rotators were tested bilaterally. External-rotation ROM was greater (t 38 = 4.92, P < .001), but IR ROM (t 38 = -8.61, P < .001) and total ROM (t 38 = -3.55, P = .01) were less in the dominant shoulder, and 15 athletes had a glenohumeral IR deficit (IR ROM loss > 18°). We observed greater concentric internal-rotator (t 38 = 2.89, P = .006) and eccentric external-rotator (t 38 = 2.65, P = .01) strength in the dominant than in the nondominant shoulder. The AHD was less in the dominant shoulder (t 38 = -3.60, P < .001). Adolescent volleyball attackers demonstrated decreased IR ROM, total ROM, and AHD and increased ER ROM in their dominant shoulder. Therefore, routine screening of adolescent athletes and designing training programs for hazardous adaptive changes could be important in preventing shoulder injuries.

  8. Correlation of glenohumeral internal rotation deficit and total rotational motion to shoulder injuries in professional baseball pitchers.

    PubMed

    Wilk, Kevin E; Macrina, Leonard C; Fleisig, Glenn S; Porterfield, Ronald; Simpson, Charles D; Harker, Paul; Paparesta, Nick; Andrews, James R

    2011-02-01

    Glenohumeral internal rotation deficit (GIRD) indicates a 20° or greater loss of internal rotation of the throwing shoulder compared with the nondominant shoulder. To determine whether GIRD and a deficit in total rotational motion (external rotation + internal rotation) compared with the nonthrowing shoulder correlate with shoulder injuries in professional baseball pitchers. Case series; Level of evidence, 4. Over 3 competitive seasons (2005 to 2007), passive range of motion measurements were evaluated on the dominant and nondominant shoulders for 170 pitcher-seasons. This included 122 professional pitchers during the 3 seasons of data collection, in which some pitchers were measured during multiple seasons. Ranges of motion were measured with a bubble goniometer during the preseason, by the same examiner each year. External and internal rotation of the glenohumeral joint was assessed with the participant supine and the arm abducted 90° in the plane of the scapula, with the scapula stabilized anteriorly at the coracoid process. The reproducibility of the test methods had an intraclass correlation coefficient of .81. Days in which the player was unable to participate because of injury or surgery were recorded during the season by the medical staff of the team and defined as an injury. Pitchers with GIRD (n = 40) were nearly twice as likely to be injured as those without but without statistical significance (P = .17). Pitchers with total rotational motion deficit greater than 5° had a higher rate of injury. Minor league pitchers were more likely than major league pitchers to be injured. However, when players were injured, major league pitchers missed a significantly greater number of games than minor league pitchers. Compared with pitchers without GIRD, pitchers with GIRD appear to be at a higher risk for injury and shoulder surgery.

  9. Use of a shoulder abduction brace after arthroscopic rotator cuff repair: A study on gait performance and falls.

    PubMed

    Sonoda, Yuma; Nishioka, Takashi; Nakajima, Ryo; Imai, Shinji; Vigers, Piers; Kawasaki, Taku

    2018-04-01

    Fall prevention is essential in patients after arthroscopic rotator cuff repair because of the high risk of re-rupture. However, there are no reports related to falls that occur during the early postoperative period, while the affected limb is immobilized. This study assessed gait performance and falls in patients using a shoulder abduction brace after arthroscopic rotator cuff repair. Prospective cohort and postoperative repeated measures. This study included 29 patients (mean age, 67.1 ± 7.4 years) who underwent arthroscopic rotator cuff repair followed by rehabilitation. The timed up and go test, Geriatric Depression Scale, and Falls Efficacy Scale were measured, and the numbers of falls were compared between those shoulder abduction brace users and patients who had undergone total hip or knee arthroplasty. In arthroscopic rotator cuff repair patients, there were significant improvements in timed up and go test and Geriatric Depression Scale, but no significant differences in Falls Efficacy Scale, between the second and fifth postoperative weeks ( p < 0.05). Additionally, arthroscopic rotator cuff repair patients fell more often than patients with total hip arthroplasty or total knee arthroplasty during the same period. The findings suggest that rehabilitation in arthroscopic rotator cuff repair patients is beneficial, but decreased gait performance due to the immobilizing shoulder abduction brace can lead to falls. Clinical relevance Although rehabilitation helps motor function and mental health after arthroscopic rotator cuff repair, shoulder abduction brace use is associated with impaired gait performance, high Falls Efficacy Scale scores, and risk of falls, so awareness of risk factors including medications and lower limb dysfunctions is especially important after arthroscopic rotator cuff repair.

  10. Visual Acuity Using Head-fixed Displays During Passive Self and Surround Motion

    NASA Technical Reports Server (NTRS)

    Wood, Scott J.; Black, F. Owen; Stallings, Valerie; Peters, Brian

    2007-01-01

    The ability to read head-fixed displays on various motion platforms requires the suppression of vestibulo-ocular reflexes. This study examined dynamic visual acuity while viewing a head-fixed display during different self and surround rotation conditions. Twelve healthy subjects were asked to report the orientation of Landolt C optotypes presented on a micro-display fixed to a rotating chair at 50 cm distance. Acuity thresholds were determined by the lowest size at which the subjects correctly identified 3 of 5 optotype orientations at peak velocity. Visual acuity was compared across four different conditions, each tested at 0.05 and 0.4 Hz (peak amplitude of 57 deg/s). The four conditions included: subject rotated in semi-darkness (i.e., limited to background illumination of the display), subject stationary while visual scene rotated, subject rotated around a stationary visual background, and both subject and visual scene rotated together. Visual acuity performance was greatest when the subject rotated around a stationary visual background; i.e., when both vestibular and visual inputs provided concordant information about the motion. Visual acuity performance was most reduced when the subject and visual scene rotated together; i.e., when the visual scene provided discordant information about the motion. Ranges of 4-5 logMAR step sizes across the conditions indicated the acuity task was sufficient to discriminate visual performance levels. The background visual scene can influence the ability to read head-fixed displays during passive motion disturbances. Dynamic visual acuity using head-fixed displays can provide an operationally relevant screening tool for visual performance during exposure to novel acceleration environments.

  11. On the stiffness matrix of the intervertebral joint: application to total disk replacement.

    PubMed

    O'Reilly, Oliver M; Metzger, Melodie F; Buckley, Jenni M; Moody, David A; Lotz, Jeffrey C

    2009-08-01

    The traditional method of establishing the stiffness matrix associated with an intervertebral joint is valid only for infinitesimal rotations, whereas the rotations featured in spinal motion are often finite. In the present paper, a new formulation of this stiffness matrix is presented, which is valid for finite rotations. This formulation uses Euler angles to parametrize the rotation, an associated basis, which is known as the dual Euler basis, to describe the moments, and it enables a characterization of the nonconservative nature of the joint caused by energy loss in the poroviscoelastic disk and ligamentous support structure. As an application of the formulation, the stiffness matrix of a motion segment is experimentally determined for the case of an intact intervertebral disk and compared with the matrices associated with the same segment after the insertion of a total disk replacement system. In this manner, the matrix is used to quantify the changes in the intervertebral kinetics associated with total disk replacements. As a result, this paper presents the first such characterization of the kinetics of a total disk replacement.

  12. Deficits in glenohumeral passive range of motion increase risk of elbow injury in professional baseball pitchers: a prospective study.

    PubMed

    Wilk, Kevin E; Macrina, Leonard C; Fleisig, Glenn S; Aune, Kyle T; Porterfield, Ron A; Harker, Paul; Evans, Timothy J; Andrews, James R

    2014-09-01

    Injuries to the elbow joint in baseball pitchers appear common. There appears to be a correlation between shoulder range of motion and elbow injuries. To prospectively determine whether decreased ROM of the throwing shoulder is correlated with the onset of elbow injuries in professional baseball pitchers. Cohort study; Level of evidence, 2. For 8 consecutive years (2005-2012), passive range of motion of both the throwing and nonthrowing shoulders of all major and minor league pitchers within a single professional baseball organization were measured by using a bubble goniometer during spring training. In total, 505 examinations were conducted on 296 pitchers. Glenohumeral external rotation and internal rotation were assessed in the supine position with the arm at 90° of abduction and in the plane of the scapula. The scapula was stabilized per methods previously established. Total rotation was defined as the sum of external rotation and internal rotation. Passive shoulder flexion was assessed with the subject supine and the scapula stabilized per methods previously established. Elbow injuries and days missed because of elbow injuries were assessed and recorded by the medical staff of the team. Throwing and nonthrowing shoulder measurements were compared by using Student t tests; 1-tailed Fisher exact tests were performed to identify significant associations between shoulder motion and elbow injury. Nominal logistic regression was performed to determine the odds of elbow injury. Significant differences were noted during side-to-side comparisons within subjects. There were 49 elbow injuries and 8 surgeries in 38 players, accounting for a total of 2551 days missed. Neither glenohumeral internal rotation deficit nor external rotation insufficiency was correlated with elbow injuries. Pitchers with deficits of >5° in total rotation in their throwing shoulders had a 2.6 times greater risk for injury. Pitchers with deficit of ≥5° in flexion of the throwing shoulder had a 2.8 times greater risk for injury. Bilateral differences in shoulder total rotation and flexion had a significant effect on the risk for elbow injuries in pitchers. Clinicians need to be aware of these findings and plan preventive programs that address these issues in hopes of reducing elbow injuries. © 2014 The Author(s).

  13. Influence of Playing a Prolonged Tennis Match on Shoulder Internal Range of Motion.

    PubMed

    Martin, Caroline; Kulpa, Richard; Ezanno, Felix; Delamarche, Paul; Bideau, Benoit

    2016-08-01

    Shoulder range of motion (ROM) deficits have been identified as an injury risk factor among tennis players. It is well known that shoulder internal rotation deficit increases with age and years of play, but there is a lack of knowledge regarding the influence of a prolonged tennis match on shoulder ROM. To examine changes in shoulder ROM during a prolonged tennis match. Descriptive laboratory study. Shoulder passive internal and external rotation ROM were measured on 8 male tennis players before, every 30 minutes during, and just after a 3-hour tennis match. Total ROM was calculated as the combination of shoulder internal and external rotations. Ball velocity on the serve was measured with a radar gun before, at midmatch, and just after the match. Decreases in shoulder internal rotation (-20.8°; P = .005), total ROM (-24.6°; P = .001), and serve velocity (-1.8 m/s; P = .002) were observed at the end of the match. No statistically significant difference was observed for shoulder external rotation after the match (P = .460). Passive shoulder internal rotation and total ROM are significantly decreased during a 3-hour tennis match. The results show that a prolonged tennis match play can modify values of shoulder ROM. © 2016 The Author(s).

  14. Association between rotation-related impairments and activity type in people with and without low back pain

    PubMed Central

    Weyrauch, Stephanie A.; Bohall, Sara C.; Sorensen, Christopher J.; Van Dillen, Linda R.

    2015-01-01

    Objective To determine if people with low back pain (LBP) who regularly participated in a rotation-related activity displayed more rotation-related impairments than people without LBP who did and did not participate in the activity. Design Secondary analysis of data from a case-control study. Setting Musculoskeletal analysis laboratory at an academic medical center. Participants A convenience sample of 55 participants with LBP who participated in a rotation-related sport, 26 back healthy controls who participated in a rotation-related sport (BHC+RRS) and 42 back healthy controls who did not participate in a rotation-related sport (BHC-RRS). Participants were matched based on age, gender, and activity level. Interventions Not applicable. Main Outcome Measures The total number of rotation-related impairments and asymmetric rotation-related impairments identified during a standardized clinical examination. Results Compared to the BHC-RRS group, both the LBP and BHC+RRS groups displayed significantly more (1) rotation-related impairments (LBP: p<.001; BHC+RRS: p=.015) (2) asymmetric rotation-related impairments (LBP: p=.006; BHC+RRS: p=.020) and (3) rotation-related impairments with trunk movement tests (LBP: p=.002; BHC+RRS: p<.001). The LBP group had significantly more rotation-related impairments with extremity movement tests than both of the back healthy groups (BHC+RRS: p=.011; BHC-RRS: p<.001). Conclusions LBP and BHC+RRS groups demonstrated a similar number of total rotation-related impairments and asymmetric rotation-related impairments, and these numbers were greater than those of the BHC-RRS group. Compared to people without LBP, people with LBP displayed more rotation-related impairments when moving an extremity. These findings suggest that impairments associated with extremity movements may be associated with having a LBP condition. PMID:25933914

  15. A simple model for studying rotation errors of gimbal mount axes in laser tracking system based on spherical mirror as a reflection unit

    NASA Astrophysics Data System (ADS)

    Song, Huixu; Shi, Zhaoyao; Chen, Hongfang; Sun, Yanqiang

    2018-01-01

    This paper presents a novel experimental approach and a simple model for verifying that spherical mirror of laser tracking system could lessen the effect of rotation errors of gimbal mount axes based on relative motion thinking. Enough material and evidence are provided to support that this simple model could replace complex optical system in laser tracking system. This experimental approach and model interchange the kinematic relationship between spherical mirror and gimbal mount axes in laser tracking system. Being fixed stably, gimbal mount axes' rotation error motions are replaced by spatial micro-displacements of spherical mirror. These motions are simulated by driving spherical mirror along the optical axis and vertical direction with the use of precision positioning platform. The effect on the laser ranging measurement accuracy of displacement caused by the rotation errors of gimbal mount axes could be recorded according to the outcome of laser interferometer. The experimental results show that laser ranging measurement error caused by the rotation errors is less than 0.1 μm if radial error motion and axial error motion are under 10 μm. The method based on relative motion thinking not only simplifies the experimental procedure but also achieves that spherical mirror owns the ability to reduce the effect of rotation errors of gimbal mount axes in laser tracking system.

  16. Humeral component retroversion in reverse total shoulder arthroplasty: a biomechanical study.

    PubMed

    Gulotta, Lawrence V; Choi, Dan; Marinello, Patrick; Knutson, Zakary; Lipman, Joseph; Wright, Timothy; Cordasco, Frank A; Craig, Edward V; Warren, Russell F

    2012-09-01

    Reverse total shoulder arthroplasty offers pain relief and functional improvement for patients with rotator cuff-deficient shoulders. The purpose of this study was to determine the optimal amount of humeral retroversion for this prosthesis. Six cadaveric shoulders underwent computed tomography (CT) imaging and were then dissected of soft tissues, except for their tendinous attachments. A reverse total shoulder arthroplasty was implanted in 0°, 20°, 30°, and 40° of retroversion, and the shoulders were mounted on a simulator to determine the muscle forces required to achieve 30° and 60° of scaption. CT images were converted into 3-dimensional models, and the amount of internal and external rotation was determined with computer modeling at various scaption angles. No differences were found in the forces required for 30° or 60° of scaption for any muscle, at any retroversion. With increasing retroversion, more impingement-free external rotation was obtained, with a concomitant decrease in the amount of internal rotation. Above 60°, the humerus was allowed to rotate around the glenosphere unencumbered. Increasing retroversion did not affect the muscle force requirements for scaption across the shoulder. Placing the humeral component in 0° to 20° of retroversion allows maximum internal rotation with the arm at the side, a movement that is required for daily activities. This limits external rotation with the arm at the side, but has no effect on external rotation with the arm elevated. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  17. Rotation invariants of vector fields from orthogonal moments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Bo; Kostková, Jitka; Flusser, Jan

    Vector field images are a type of new multidimensional data that appear in many engineering areas. Although the vector fields can be visualized as images, they differ from graylevel and color images in several aspects. In order to analyze them, special methods and algorithms must be originally developed or substantially adapted from the traditional image processing area. Here, we propose a method for the description and matching of vector field patterns under an unknown rotation of the field. Rotation of a vector field is so-called total rotation, where the action is applied not only on the spatial coordinates but alsomore » on the field values. Invariants of vector fields with respect to total rotation constructed from orthogonal Gaussian–Hermite moments and Zernike moments are introduced. Their numerical stability is shown to be better than that of the invariants published so far. We demonstrate their usefulness in a real world template matching application of rotated vector fields.« less

  18. Rotation invariants of vector fields from orthogonal moments

    DOE PAGES

    Yang, Bo; Kostková, Jitka; Flusser, Jan; ...

    2017-09-11

    Vector field images are a type of new multidimensional data that appear in many engineering areas. Although the vector fields can be visualized as images, they differ from graylevel and color images in several aspects. In order to analyze them, special methods and algorithms must be originally developed or substantially adapted from the traditional image processing area. Here, we propose a method for the description and matching of vector field patterns under an unknown rotation of the field. Rotation of a vector field is so-called total rotation, where the action is applied not only on the spatial coordinates but alsomore » on the field values. Invariants of vector fields with respect to total rotation constructed from orthogonal Gaussian–Hermite moments and Zernike moments are introduced. Their numerical stability is shown to be better than that of the invariants published so far. We demonstrate their usefulness in a real world template matching application of rotated vector fields.« less

  19. Basin analysis in the Southern Tethyan margin: Facies sequences, stratal pattern and subsidence history highlight extension-to-inversion processes in the Cretaceous Panormide carbonate platform (NW Sicily)

    NASA Astrophysics Data System (ADS)

    Basilone, Luca; Sulli, Attilio

    2018-01-01

    In the Mediterranean, the South-Tethys paleomargin experienced polyphased tectonic episodes and paleoenvironmental perturbations during Mesozoic time. The Cretaceous shallow-water carbonate successions of the Panormide platform, outcropping in the northern edge of the Palermo Mountains (NW Sicily), were studied by integrating facies and stratal pattern with backstripping analysis to recognize the tectonics vs. carbonate sedimentation interaction. The features of the Requienid limestone, including geometric configuration, facies sequence, lithological changes and significance of the top-unconformity, highlight that at the end of the Lower Cretaceous the carbonate platform was tectonically dismembered in various rotating fault-blocks. The variable trends of the subsidence curves testify to different responses, both uplift and downthrow, of various platform-blocks impacted by extensional tectonics. Physical stratigraphic and facies analysis of the Rudistid limestone highlight that during the Upper Cretaceous the previously carbonate platform faulted-blocks were subjected to vertical movements in the direction opposite to the displacement produced by the extensional tectonics, indicating a positive tectonic inversion. Comparisons with other sectors of the Southern Tethyan and Adria paleomargins indicate that during the Cretaceous these areas underwent the same extensional and compressional stages occurring in the Panormide carbonate platform, suggesting a regional scale significance, in time and kinematics, for these tectonic events.

  20. Application of virtual distances methodology to laser tracker verification with an indexed metrology platform

    NASA Astrophysics Data System (ADS)

    Acero, R.; Santolaria, J.; Pueo, M.; Aguilar, J. J.; Brau, A.

    2015-11-01

    High-range measuring equipment like laser trackers need large dimension calibrated reference artifacts in their calibration and verification procedures. In this paper, a new verification procedure for portable coordinate measuring instruments based on the generation and evaluation of virtual distances with an indexed metrology platform is developed. This methodology enables the definition of an unlimited number of reference distances without materializing them in a physical gauge to be used as a reference. The generation of the virtual points and reference lengths derived is linked to the concept of the indexed metrology platform and the knowledge of the relative position and orientation of its upper and lower platforms with high accuracy. It is the measuring instrument together with the indexed metrology platform one that remains still, rotating the virtual mesh around them. As a first step, the virtual distances technique is applied to a laser tracker in this work. The experimental verification procedure of the laser tracker with virtual distances is simulated and further compared with the conventional verification procedure of the laser tracker with the indexed metrology platform. The results obtained in terms of volumetric performance of the laser tracker proved the suitability of the virtual distances methodology in calibration and verification procedures for portable coordinate measuring instruments, broadening and expanding the possibilities for the definition of reference distances in these procedures.

  1. Descriptive profile of hip rotation range of motion in elite tennis players and professional baseball pitchers.

    PubMed

    Ellenbecker, Todd S; Ellenbecker, Gail A; Roetert, E Paul; Silva, Rogerio Teixeira; Keuter, Greg; Sperling, Fabio

    2007-08-01

    Repetitive loading to the hip joint in athletes has been reported as a factor in the development of degenerative joint disease and intra-articular injury. Little information is available on the bilateral symmetry of hip rotational measures in unilaterally dominant upper extremity athletes. Side-to-side differences in hip joint range of motion may be present because of asymmetrical loading in the lower extremities of elite tennis players and professional baseball pitchers. Cohort (cross-sectional) study (prevalence); Level of evidence, 1. Descriptive measures of hip internal and external rotation active range of motion were taken in the prone position of 64 male and 83 female elite tennis players and 101 male professional baseball pitchers using digital photos and computerized angle calculation software. Bilateral differences in active range of motion between the dominant and nondominant hip were compared using paired t tests and Bonferroni correction for hip internal, external, and total rotation range of motion. A Pearson correlation test was used to test the relationship between years of competition and hip rotation active range of motion. No significant bilateral difference (P > .005) was measured for mean hip internal or external rotation for the elite tennis players or the professional baseball pitchers. An analysis of the number of subjects in each group with a bilateral difference in hip rotation greater than 10 degrees identified 17% of the professional baseball pitchers with internal rotation differences and 42% with external rotation differences. Differences in the elite male tennis players occurred in only 15% of the players for internal rotation and 9% in external rotation. Female subjects had differences in 8% and 12% of the players for internal and external rotation, respectively. Statistical differences were found between the mean total arc of hip range of internal and external rotation in the elite tennis players with the dominant side being greater by a clinically insignificant mean value of 2.5 degrees. Significantly less (P < .005) dominant hip internal rotation and less dominant and nondominant hip total rotation range of motion were found in the professional baseball pitchers compared with the elite male tennis players. This study established typical range of motion patterns and identified bilaterally symmetric hip active range of motion rotation values in elite tennis players and professional baseball pitchers. Asymmetric hip joint rotational active range of motion encountered during clinical examination and screening may indicate abnormalities and would indicate the application of flexibility training, rehabilitation, and further evaluation.

  2. Optimized functional femoral rotation in navigated total knee arthroplasty considering ligament tension.

    PubMed

    Walde, T A; Bussert, J; Sehmisch, S; Balcarek, P; Stürmer, K M; Walde, H J; Frosch, K H

    2010-12-01

    Femoral malrotation in total knee arthroplasty is correlated to an increased number of revisions. Anatomic landmarks such as Whiteside line, posterior condyle axis and transepicondylar axis are used for determining femoral component rotation. The femoral rotation achieved with the anatomical landmarks is compared to the femoral rotation achieved by a navigated ligament tension-based tibia-first technique. Ninety-three consecutive patients with gonarthritis were prospectively enrolled. Intraoperatively the anatomical landmarks for femoral rotation and the achieved femoral rotation using a navigated tension-based tibia-first technique were determined and stored for further comparison. A pre- and postoperative functional diagram displaying the extension and flexion and varus or valgus positions was also part of the evaluation. Using anatomical landmarks the rotational errors ranged from 12.2° of internal rotation to 15.5° of external rotation from parallel to the tibial resection surface at 90° flexion. A statistical significant improved femoral rotation was achieved using the ligament tension-based method with a rotational error ranged from 3.0° of internal rotation to 2.4° of external rotation. The functional analyses demonstrated statistical significant lower varus/valgus deviations within the flexion range and an improved maximum varus deviation at 90° flexion using the ligament tension-based method. Compared to the anatomical landmarks a balanced, almost parallel flexion gap was achieved using a navigation technique taking the ligament tension of the knee joint into account. As a result the improved femoral rotation was demonstrated by the functional evaluation. Unilateral overloading of the polyethylene inlay and unilateral instability can thus be avoided. Copyright © 2009 Elsevier B.V. All rights reserved.

  3. Solar rotational modulations of spectral irradiance and correlations with the variability of total solar irradiance

    NASA Astrophysics Data System (ADS)

    Lee, Jae N.; Cahalan, Robert F.; Wu, Dong L.

    2016-09-01

    Aims: We characterize the solar rotational modulations of spectral solar irradiance (SSI) and compare them with the corresponding changes of total solar irradiance (TSI). Solar rotational modulations of TSI and SSI at wavelengths between 120 and 1600 nm are identified over one hundred Carrington rotational cycles during 2003-2013. Methods: The SORCE (Solar Radiation and Climate Experiment) and TIMED (Thermosphere Ionosphere Mesosphere Energetics and Dynamics)/SEE (Solar EUV Experiment) measured and SATIRE-S modeled solar irradiances are analyzed using the EEMD (Ensemble Empirical Mode Decomposition) method to determine the phase and amplitude of 27-day solar rotational variation in TSI and SSI. Results: The mode decomposition clearly identifies 27-day solar rotational variations in SSI between 120 and 1600 nm, and there is a robust wavelength dependence in the phase of the rotational mode relative to that of TSI. The rotational modes of visible (VIS) and near infrared (NIR) are in phase with the mode of TSI, but the phase of the rotational mode of ultraviolet (UV) exhibits differences from that of TSI. While it is questionable that the VIS to NIR portion of the solar spectrum has yet been observed with sufficient accuracy and precision to determine the 11-year solar cycle variations, the temporal variations over one hundred cycles of 27-day solar rotation, independent of the two solar cycles in which they are embedded, show distinct solar rotational modulations at each wavelength.

  4. Solar Rotational Modulations of Spectral Irradiance and Correlations with the Variability of Total Solar Irradiance

    NASA Technical Reports Server (NTRS)

    Lee, Jae N.; Cahalan, Robert F.; Wu, Dong L.

    2016-01-01

    Aims: We characterize the solar rotational modulations of spectral solar irradiance (SSI) and compare them with the corresponding changes of total solar irradiance (TSI). Solar rotational modulations of TSI and SSI at wavelengths between 120 and 1600 nm are identified over one hundred Carrington rotational cycles during 2003-2013. Methods: The SORCE (Solar Radiation and Climate Experiment) and TIMED (Thermosphere Ionosphere Mesosphere Energetics and Dynamics)/SEE (Solar EUV Experiment) measured and SATIRE-S modeled solar irradiances are analyzed using the EEMD (Ensemble Empirical Mode Decomposition) method to determine the phase and amplitude of 27-day solar rotational variation in TSI and SSI. Results: The mode decomposition clearly identifies 27-day solar rotational variations in SSI between 120 and 1600 nm, and there is a robust wavelength dependence in the phase of the rotational mode relative to that of TSI. The rotational modes of visible (VIS) and near infrared (NIR) are in phase with the mode of TSI, but the phase of the rotational mode of ultraviolet (UV) exhibits differences from that of TSI. While it is questionable that the VIS to NIR portion of the solar spectrum has yet been observed with sufficient accuracy and precision to determine the 11-year solar cycle variations, the temporal variations over one hundred cycles of 27-day solar rotation, independent of the two solar cycles in which they are embedded, show distinct solar rotational modulations at each wavelength.

  5. Assessing the Effects of Software Platforms on Volumetric Segmentation of Glioblastoma

    PubMed Central

    Dunn, William D.; Aerts, Hugo J.W.L.; Cooper, Lee A.; Holder, Chad A.; Hwang, Scott N.; Jaffe, Carle C.; Brat, Daniel J.; Jain, Rajan; Flanders, Adam E.; Zinn, Pascal O.; Colen, Rivka R.; Gutman, David A.

    2017-01-01

    Background Radiological assessments of biologically relevant regions in glioblastoma have been associated with genotypic characteristics, implying a potential role in personalized medicine. Here, we assess the reproducibility and association with survival of two volumetric segmentation platforms and explore how methodology could impact subsequent interpretation and analysis. Methods Post-contrast T1- and T2-weighted FLAIR MR images of 67 TCGA patients were segmented into five distinct compartments (necrosis, contrast-enhancement, FLAIR, post contrast abnormal, and total abnormal tumor volumes) by two quantitative image segmentation platforms - 3D Slicer and a method based on Velocity AI and FSL. We investigated the internal consistency of each platform by correlation statistics, association with survival, and concordance with consensus neuroradiologist ratings using ordinal logistic regression. Results We found high correlations between the two platforms for FLAIR, post contrast abnormal, and total abnormal tumor volumes (spearman’s r(67) = 0.952, 0.959, and 0.969 respectively). Only modest agreement was observed for necrosis and contrast-enhancement volumes (r(67) = 0.693 and 0.773 respectively), likely arising from differences in manual and automated segmentation methods of these regions by 3D Slicer and Velocity AI/FSL, respectively. Survival analysis based on AUC revealed significant predictive power of both platforms for the following volumes: contrast-enhancement, post contrast abnormal, and total abnormal tumor volumes. Finally, ordinal logistic regression demonstrated correspondence to manual ratings for several features. Conclusion Tumor volume measurements from both volumetric platforms produced highly concordant and reproducible estimates across platforms for general features. As automated or semi-automated volumetric measurements replace manual linear or area measurements, it will become increasingly important to keep in mind that measurement differences between segmentation platforms for more detailed features could influence downstream survival or radio genomic analyses. PMID:29600296

  6. Millimeter wave radar system on a rotating platform for combined search and track functionality with SAR imaging

    NASA Astrophysics Data System (ADS)

    Aulenbacher, Uwe; Rech, Klaus; Sedlmeier, Johannes; Pratisto, Hans; Wellig, Peter

    2014-10-01

    Ground based millimeter wave radar sensors offer the potential for a weather-independent automatic ground surveillance at day and night, e.g. for camp protection applications. The basic principle and the experimental verification of a radar system concept is described, which by means of an extreme off-axis positioning of the antenna(s) combines azimuthal mechanical beam steering with the formation of a circular-arc shaped synthetic aperture (SA). In automatic ground surveillance the function of search and detection of moving ground targets is performed by means of the conventional mechanical scan mode. The rotated antenna structure designed as a small array with two or more RX antenna elements with simultaneous receiver chains allows to instantaneous track multiple moving targets (monopulse principle). The simultaneously operated SAR mode yields areal images of the distribution of stationary scatterers. For ground surveillance application this SAR mode is best suited for identifying possible threats by means of change detection. The feasibility of this concept was tested by means of an experimental radar system comprising of a 94 GHz (W band) FM-CW module with 1 GHz bandwidth and two RX antennas with parallel receiver channels, placed off-axis at a rotating platform. SAR mode and search/track mode were tested during an outdoor measurement campaign. The scenery of two persons walking along a road and partially through forest served as test for the capability to track multiple moving targets. For SAR mode verification an image of the area composed of roads, grassland, woodland and several man-made objects was reconstructed from the measured data.

  7. Rapid learning of magnetic compass direction by C57BL/6 mice in a 4-armed 'plus' water maze.

    PubMed

    Phillips, John B; Youmans, Paul W; Muheim, Rachel; Sloan, Kelly A; Landler, Lukas; Painter, Michael S; Anderson, Christopher R

    2013-01-01

    Magnetoreception has been demonstrated in all five vertebrate classes. In rodents, nest building experiments have shown the use of magnetic cues by two families of molerats, Siberian hamsters and C57BL/6 mice. However, assays widely used to study rodent spatial cognition (e.g. water maze, radial arm maze) have failed to provide evidence for the use of magnetic cues. Here we show that C57BL/6 mice can learn the magnetic direction of a submerged platform in a 4-armed (plus) water maze. Naïve mice were given two brief training trials. In each trial, a mouse was confined to one arm of the maze with the submerged platform at the outer end in a predetermined alignment relative to magnetic north. Between trials, the training arm and magnetic field were rotated by 180(°) so that the mouse had to swim in the same magnetic direction to reach the submerged platform. The directional preference of each mouse was tested once in one of four magnetic field alignments by releasing it at the center of the maze with access to all four arms. Equal numbers of responses were obtained from mice tested in the four symmetrical magnetic field alignments. Findings show that two training trials are sufficient for mice to learn the magnetic direction of the submerged platform in a plus water maze. The success of these experiments may be explained by: (1) absence of alternative directional cues (2), rotation of magnetic field alignment, and (3) electromagnetic shielding to minimize radio frequency interference that has been shown to interfere with magnetic compass orientation of birds. These findings confirm that mice have a well-developed magnetic compass, and give further impetus to the question of whether epigeic rodents (e.g., mice and rats) have a photoreceptor-based magnetic compass similar to that found in amphibians and migratory birds.

  8. Rapid Learning of Magnetic Compass Direction by C57BL/6 Mice in a 4-Armed ‘Plus’ Water Maze

    PubMed Central

    Phillips, John B.; Youmans, Paul W.; Muheim, Rachel; Sloan, Kelly A.; Landler, Lukas; Painter, Michael S.; Anderson, Christopher R.

    2013-01-01

    Magnetoreception has been demonstrated in all five vertebrate classes. In rodents, nest building experiments have shown the use of magnetic cues by two families of molerats, Siberian hamsters and C57BL/6 mice. However, assays widely used to study rodent spatial cognition (e.g. water maze, radial arm maze) have failed to provide evidence for the use of magnetic cues. Here we show that C57BL/6 mice can learn the magnetic direction of a submerged platform in a 4-armed (plus) water maze. Naïve mice were given two brief training trials. In each trial, a mouse was confined to one arm of the maze with the submerged platform at the outer end in a predetermined alignment relative to magnetic north. Between trials, the training arm and magnetic field were rotated by 180° so that the mouse had to swim in the same magnetic direction to reach the submerged platform. The directional preference of each mouse was tested once in one of four magnetic field alignments by releasing it at the center of the maze with access to all four arms. Equal numbers of responses were obtained from mice tested in the four symmetrical magnetic field alignments. Findings show that two training trials are sufficient for mice to learn the magnetic direction of the submerged platform in a plus water maze. The success of these experiments may be explained by: (1) absence of alternative directional cues (2), rotation of magnetic field alignment, and (3) electromagnetic shielding to minimize radio frequency interference that has been shown to interfere with magnetic compass orientation of birds. These findings confirm that mice have a well-developed magnetic compass, and give further impetus to the question of whether epigeic rodents (e.g., mice and rats) have a photoreceptor-based magnetic compass similar to that found in amphibians and migratory birds. PMID:24023673

  9. Kinematic analysis of hip and knee rotation and other contributors to ballet turnout.

    PubMed

    Quanbeck, Amy E; Russell, Jeffrey A; Handley, Sara C; Quanbeck, Deborah S

    2017-02-01

    Turnout, or external rotation (ER) of the lower extremities, is essential in ballet. The purpose of this study was to utilise physical examination and a biomechanical method for obtaining functional kinematic data using hip and knee joint centres to identify the relative turnout contributions from hip rotation, femoral anteversion, knee rotation, tibial torsion, and other sources. Ten female dancers received a lower extremity alignment assessment, including passive hip rotation, femoral anteversion, tibial torsion, weightbearing foot alignment, and Beighton hypermobility score. Next, turnout was assessed using plantar pressure plots and three-dimensional motion analysis; participants performed turnout to ballet first position on both a plantar pressure mat and friction-reducing discs. A retro-reflective functional marker motion capture system mapped the lower extremities and hip and knee joint centres. Mean total turnout was 129±15.7° via plantar pressure plots and 135±17.8° via kinematics. Bilateral hip ER during turnout was 49±10.2° (36% of total turnout). Bilateral knee ER during turnout was 41±5.9° (32% of total turnout). Hip ER contribution to total turnout measured kinematically was less than expected compared to other studies, where hip ER was determined without functional kinematic data. Knee ER contributed substantially more turnout than expected or previously reported. This analysis method allows precise assessment of turnout contributors.

  10. The value of a core clinical rotation in urology for medical students.

    PubMed

    Patel, Premal; Nayak, Jasmir G; McGregor, Thomas B

    2015-01-01

    In 2013, our institution underwent a change to the undergraduate medical curriculum whereby a clinical urology rotation became mandatory. In this paper, we evaluated the perceived utility and value of this change in the core curriculum. Third year medical students, required to complete a mandatory 1-week clinical urology rotation, were asked to complete a survey before and after their rotation. Fourth year medical students, not required to complete this rotation, were also asked to complete a questionnaire. Chi-squared and Fisher's exact test were used for data analysis. In total, 108 third year students rotated through urology during the study period. Of these, 66 (61%) completed the pre-rotation survey and 54 (50%) completed the post-rotation survey. In total, there were 110 fourth year students. Of these, 44 (40%) completed the questionnaire. After completing their mandatory rotations, students felt more comfortable managing and investigating common urological problems, such as hematuria and renal colic. Students felt they had a better understanding of how to insert a Foley catheter and felt comfortable independently inserting a Foley catheter. Importantly, students felt they knew when to consult urology and were also more likely to consider a career in urology. Compared to fourth year students, third year students felt urology was an important component to a family medicine practice and felt they had a better understanding of when to consult urology. The introduction of a mandatory urology rotation for undergraduate medical students leads to a perceived improvement in fundamental urological knowledge and skill set of rotating students. This mandatory rotation provides a valuable experience that validates its inclusion.

  11. Indications for reverse total shoulder arthroplasty in rotator cuff disease.

    PubMed

    Drake, Gregory N; O'Connor, Daniel P; Edwards, T Bradley

    2010-06-01

    Reverse total shoulder arthroplasty (RTSA) was introduced to treat rotator cuff tear arthropathy but is now used to treat a variety of problems. Although its use has expanded substantially since the FDA's approval in 2004, the appropriateness in patients with rotator cuff disease is unclear. We review the use of RTSA in patients with rotator cuff disease to (1) describe classification of rotator cuff tear reparability and the concept of a balanced shoulder; (2) explore the theory behind RTSA design relative to rotator cuff arthropathy; (3) discuss the indications and contraindications for RTSA; and (4) review published outcomes of RTSA for rotator cuff arthropathy. We performed a selective review of the literature on the use of RTSA in the treatment of rotator cuff disease. Modern RTSA designs restore deltoid tension and a functional fulcrum to the rotator cuff deficient shoulder, which allows recovery of active shoulder elevation and effectively restores function in short- and medium-term followup studies. In short-term followup the RTSA relieves symptoms and restores function for patients with cuff tear arthropathy and irreparable rotator cuff tears with pseudoparalysis (preserved deltoid contraction but loss of active elevation). Severely impaired deltoid function, an isolated supraspinatus tear, and the presence of full active shoulder elevation with a massive rotator cuff tear and arthritis are contraindications to RTSA. For properly selected patients who have symptomatic and disabling rotator cuff deficiency, RTSA can result in life-changing improvements in pain, motion, function, and patient satisfaction. Level V therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  12. Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

    NASA Astrophysics Data System (ADS)

    Li, J.; Xiong, L. Y.; Peng, N.; Dong, B.; Wang, P.; Liu, L. Q.

    2014-01-01

    An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemens S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.

  13. Anser EMT: the first open-source electromagnetic tracking platform for image-guided interventions.

    PubMed

    Jaeger, Herman Alexander; Franz, Alfred Michael; O'Donoghue, Kilian; Seitel, Alexander; Trauzettel, Fabian; Maier-Hein, Lena; Cantillon-Murphy, Pádraig

    2017-06-01

    Electromagnetic tracking is the gold standard for instrument tracking and navigation in the clinical setting without line of sight. Whilst clinical platforms exist for interventional bronchoscopy and neurosurgical navigation, the limited flexibility and high costs of electromagnetic tracking (EMT) systems for research investigations mitigate against a better understanding of the technology's characterisation and limitations. The Anser project provides an open-source implementation for EMT with particular application to image-guided interventions. This work provides implementation schematics for our previously reported EMT system which relies on low-cost acquisition and demodulation techniques using both National Instruments and Arduino hardware alongside MATLAB support code. The system performance is objectively compared to other commercial tracking platforms using the Hummel assessment protocol. Positional accuracy of 1.14 mm and angular rotation accuracy of [Formula: see text] are reported. Like other EMT platforms, Anser is susceptible to tracking errors due to eddy current and ferromagnetic distortion. The system is compatible with commercially available EMT sensors as well as the Open Network Interface for image-guided therapy (OpenIGTLink) for easy communication with visualisation and medical imaging toolkits such as MITK and 3D Slicer. By providing an open-source platform for research investigations, we believe that novel and collaborative approaches can overcome the limitations of current EMT technology.

  14. Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, J.; Xiong, L. Y.; Peng, N.

    2014-01-29

    An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemensmore » S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.« less

  15. Towards a Low-Cost Quadrotor Research Platform

    DTIC Science & Technology

    2010-03-01

    FIGURES Figure 1. Quadrotor schematic showing rotor direction of rotation (From [2])................3 Figure 2. Toy quadrotor: Walkera UFO (from...Some examples are the Walkera UFO #5, Walkera UFO #8, Dragonfly, and Alien Air Jump Jet. Figure 2. Toy quadrotor: Walkera UFO (from Walkera...the X- UFO made by Silverlit Electronics used small mechanical gyros. These were relatively cheap due to low-cost labor, but suffered from mechanical

  16. Managing External and Internal Support Requirements

    DTIC Science & Technology

    2016-03-14

    and the management of medical evacu- ation platforms within the medical company. BSB Rehearsals A contributing factor to the in- ability to separate...the two support areas is often observed during JRTC rotations when BSBs do not have a battalion-level rehearsal (incorporat- ing movement and...occupation) but instead incorporate battalion internal operations into the BCT sustain- ment rehearsal . Th is quickly leads to confusion on the objective

  17. Kinematics of Laying an Automated Weapon System

    DTIC Science & Technology

    2017-07-19

    mathematical transformation is required to move the firing solution from its reference frame to a reference frame that is meaningful to the weapon system. This...Procedures 2 Conventions and Variable Definitions 2 Rotation Matrices 5 Transformation of a Vector 5 Conversion Between Cartestian and Spherical...Coordinate Systems 6 Transformation of Earth Referenced Lay to Platform Reference Frame 6 Results and Discussions 7 Conclusions 8 Bibliography 9

  18. A conjugated microporous polymer based visual sensing platform for aminoglycoside antibiotics in water.

    PubMed

    Bhunia, Subhajit; Dey, Nilanjan; Pradhan, Anirban; Bhattacharya, Santanu

    2018-06-20

    A donor-acceptor based conjugated microporous polymer, PER@NiP-CMOP-1, has been synthesized which can achieve highly sensitive stereo-specific "Turn ON" biosensing of an aminoglycoside up to the ppb level. The coordination-driven inhibition of photo-induced electron transfer (d-PET) for d-electrons and the rotational freezing are the key factors for the recovery of the emission.

  19. General view of the Solid Rocket Booster's (SRB) Solid Rocket ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    General view of the Solid Rocket Booster's (SRB) Solid Rocket Motor Segments in the Surge Building of the Rotation Processing and Surge Facility at Kennedy Space Center awaiting transfer to the Vehicle Assembly Building and subsequent mounting and assembly on the Mobile Launch Platform. - Space Transportation System, Solid Rocket Boosters, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX

  20. U.S. Marine Corps Level-Dependent Hearing Protector Assessment: Objective Measures of Hearing Protection Devices

    DTIC Science & Technology

    2014-01-01

    12 4.2.1 Loudspeaker Array ...Instrumentation 4.2.1 Loudspeaker Array Target stimuli were presented from a spherical loudspeaker array consisting of 57 Meyer Sound MM-4XP miniature... loudspeaker array on a raised platform that placed their ears at the same elevation as the 0° loudspeaker ring. The chair was free to rotate 360° and

  1. Effect of voluntary soft tissue tension and articular conformity after total knee arthroplasty on in vivo anteroposterior displacement.

    PubMed

    Ishii, Y; Noguchi, H; Takeda, M; Kiga, H; Toyabe, S I

    2011-01-01

    The in vivo relationship between the degree of voluntary soft tissue tension and articular conformity after total knee arthroplasty (TKA) and anteroposterior (AP) displacement was simultaneously investigated by analyzing LCS prostheses (posterior cruciate ligament-sacrificing rotating platform design) in 20 knees from 20 patients. AP displacement was measured using the KT-2000 arthrometer, at 30° and 75° flexion, while patients were conscious and under anesthesia; 30° flexion was regarded as high conformity and 75° as low conformity. Mean displacements at 30° and 75° were 5.1mm and 7.0mm, respectively, in conscious patients, and 6.7 mm and 7.7 mm, respectively, in patients under anesthesia. AP displacement was significantly associated with soft tissue tension (p=0.026) and conformity (p=0.001). No interaction was observed between the two variables (p=0.193). Surgeons should recognize that AP displacement is greater in anesthetized patients than in conscious patients, regardless of the degree of conformity, and that higher conformity shows less displacement, regardless of the degree of soft tissue tension. These results may help surgeons to determine the intra-operative AP displacement required for proper postoperative displacement in the current prosthetic design. Copyright © 2009 Elsevier B.V. All rights reserved.

  2. Staying connected: Service-specific orientation can be successfully achieved using a mobile application for onboarding care providers

    PubMed Central

    Chreiman, Kristen M; Prakash, Priya S; Kim, Patrick K; Mehta, Samir; McGinnis, Kelly; Gallagher, John J; Reilly, Patrick M

    2017-01-01

    Communicating service-specific practice patterns, guidelines, and provider information to a new team of learners that rotate frequently can be challenging. Leveraging individual and healthcare electronic resources, a mobile device platform was implemented into a newly revised resident onboarding process. We hypothesized that offering an easy-to-use mobile application would improve communication across multiple disciplines as well as improve provider experiences when transitioning to a new rotation. A mobile platform was created and deployed to assist with enhancing communication within a trauma service and its resident onboarding process. The platform had resource materials such as: divisional policies, Clinical Practice Guidelines (CMGs), and onboarding manuals along with allowing for the posting of divisional events, a divisional directory that linked to direct dialing, text or email messaging, as well as on-call schedules. A mixed-methods study, including an anonymous survey, aimed at providing information on team member's impressions and usage of the mobile application was performed. Usage statistics over a 3-month period were analyzed on those providers who completed the survey. After rotation on the trauma service, trainees were asked to complete an anonymous, online survey addressing both the experience with, as well as the utility of, the mobile app. Thirty of the 37 (81%) residents and medical students completed the survey. Twenty-five (83%) trainees stated that this was their first experience rotating on the trauma service and 6 (20%) were from outside of the health system. According to those surveyed, the most useful function of the app were access to the directory (15, 50%), the divisional calendar (4, 13.3%), and the on-call schedules (3, 10%). Overall, the app was felt to be easy to use (27, 90%) and was accessed an average of 7 times per day (1–50, SD 9.67). Over half the survey respondents felt that the mobile app was helpful in completing their everyday tasks (16, 53.3%). Fifteen (50%) of the respondents stated that the app made the transition to the trauma service easier. Twenty-five (83.3%) stated it was valuable knowing about departmental events and announcements, and 17 (56.7%) felt more connected to the division. The evolution of mobile technology is rapidly becoming fundamental in medical education and training. We found that integrating a service-specific mobile application improved the learner's experience when transitioning to a new service and was a valuable onboarding instrument. Level of evidence IV. PMID:29766089

  3. Staying connected: Service-specific orientation can be successfully achieved using a mobile application for onboarding care providers.

    PubMed

    Chreiman, Kristen M; Prakash, Priya S; Martin, Niels D; Kim, Patrick K; Mehta, Samir; McGinnis, Kelly; Gallagher, John J; Reilly, Patrick M

    2017-01-01

    Communicating service-specific practice patterns, guidelines, and provider information to a new team of learners that rotate frequently can be challenging. Leveraging individual and healthcare electronic resources, a mobile device platform was implemented into a newly revised resident onboarding process. We hypothesized that offering an easy-to-use mobile application would improve communication across multiple disciplines as well as improve provider experiences when transitioning to a new rotation. A mobile platform was created and deployed to assist with enhancing communication within a trauma service and its resident onboarding process. The platform had resource materials such as: divisional policies, Clinical Practice Guidelines (CMGs), and onboarding manuals along with allowing for the posting of divisional events, a divisional directory that linked to direct dialing, text or email messaging, as well as on-call schedules. A mixed-methods study, including an anonymous survey, aimed at providing information on team member's impressions and usage of the mobile application was performed. Usage statistics over a 3-month period were analyzed on those providers who completed the survey. After rotation on the trauma service, trainees were asked to complete an anonymous, online survey addressing both the experience with, as well as the utility of, the mobile app. Thirty of the 37 (81%) residents and medical students completed the survey. Twenty-five (83%) trainees stated that this was their first experience rotating on the trauma service and 6 (20%) were from outside of the health system. According to those surveyed, the most useful function of the app were access to the directory (15, 50%), the divisional calendar (4, 13.3%), and the on-call schedules (3, 10%). Overall, the app was felt to be easy to use (27, 90%) and was accessed an average of 7 times per day (1-50, SD 9.67). Over half the survey respondents felt that the mobile app was helpful in completing their everyday tasks (16, 53.3%). Fifteen (50%) of the respondents stated that the app made the transition to the trauma service easier. Twenty-five (83.3%) stated it was valuable knowing about departmental events and announcements, and 17 (56.7%) felt more connected to the division. The evolution of mobile technology is rapidly becoming fundamental in medical education and training. We found that integrating a service-specific mobile application improved the learner's experience when transitioning to a new service and was a valuable onboarding instrument. Level of evidence IV.

  4. Influence of number of dental autoclave treatment cycles on rotational performance of commercially available air-turbine handpieces.

    PubMed

    Nagai, Masahiro; Takakuda, Kazuo

    2006-06-01

    The influence of number of autoclave treatment cycles (N) on rotational speed and total indicated run-out of commercially available air-turbine handpieces from five manufacturers was investigated at N=0, 50, 100, 150, 200, 250 and 300 cycles, and the significance in the test results was assessed by Dunnett's multiple comparison test. Some air-turbine handpieces showed the significant differences in rotational speed at N=300 cycles, however, the decreases of the rotational speeds were only 1 to 3.5 percent. Some air-turbine handpieces showed the significant differences in total indicated run-out, however, the respective values were smaller than that at N=0 cycle. Accordingly, it can be considered that the ball bearing in the air-turbine handpieces is not affected significantly by autoclave. To further evaluate rotational performance, this study focused on the rotational vibration of the ball bearing components of the air-turbine, as measured by Fast Fourier Transform (FFT) analysis; the power spectra of frequency of the ball's revolution, frequency of the cage's rotation and frequency of the ball's rotation were comparatively investigated at N=0, 150 and 300 cycles, and the influence of autoclave was evaluated qualitatively. No abnormalities in the ball bearings were recognized.

  5. C. G. Doris participation in the development of Abu-Al-Bu Koosh Field (in English and French)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    On behalf of the total-ABK group, the company, C.G. Doris, has taken an active part in the development of the gas-lift and water injection installations in the Abu-Al-Bu Koosh Fields. The gas lift platform is a 4-legged jacket in 30 m of water with 2 deck levels. It is joined by a bridge to the production platform. Total load of the new platform is 1000 tons of steel plus 200 tons of piles. The 2 water injection tripods in 41 and 27 m of water also are pile-supported jackets with the vertical and 2 inclined legs. Also, the 2 workovermore » platforms have been thoroughly rechecked by C.G. Doris. Furthermore, a living quarters platform was designed and contracted by the company on a turn-key basis. Capacity is 60 people, with a possibility of expansion.« less

  6. The influence of patient factors on femoral rotation after total hip arthroplasty.

    PubMed

    Tezuka, Taro; Inaba, Yutaka; Kobayashi, Naomi; Choe, Hyonmin; Higashihira, Syota; Saito, Tomoyuki

    2018-06-09

    A postoperative change in femoral rotation following total hip arthroplasty (THA) might be the cause of dislocation due to the change in combined anteversion. However, very few studies have evaluated the femoral rotation angle following THA, or the factors that influence femoral rotation. We aimed to evaluate changes in femoral rotation after THA, and to investigate preoperative patient factors that influence femoral rotation after THA. This study involved 211 hips treated with primary THA. We used computed tomography to measure the femoral rotation angle before and one week after THA. In addition, multiple regression analysis was performed to evaluate preoperative patient factors that could influence femoral rotation after THA. The femoral rotation angle was 0.2 ± 14° externally before surgery and 4.4 ± 12° internally after surgery (p < 0.001). Multiple regression analysis revealed that sex (β = 0.19; p = 0.003), age (β = 0.15; p = 0.017), preoperative anatomical femoral anteversion (β = - 0.25; p = 0.002), and preoperative femoral rotation angle (β = 0.36; p < 0.001) were significantly associated with the postoperative femoral rotation angle. The final model of the regression formula was described by the following equation: [postoperative femoral rotation angle = 5.41 × sex (female: 0, male: 1) + 0.15 × age - 0.22 × preoperative anatomical femoral anteversion + 0.33 × preoperative femoral rotation angle - 10.1]. The current study showed the mean internal change of 4.6° in the femoral rotation angle one week after THA. Sex, age, preoperative anatomical femoral anteversion and preoperative femoral rotation were associated with postoperative femoral rotation. The patients who were male, older, and who exhibited lesser preoperative anatomical femoral anteversion or greater preoperative femoral rotation angles, tended to demonstrate an externally rotated femur after THA. Conversely, patients who were female, younger, and who exhibited greater preoperative anatomical femoral anteversion or lesser preoperative femoral rotation angles, tended to demonstrate an internal rotation of the femur after THA.

  7. Perioperative Serum Lipid Status and Statin Use Affect the Revision Surgery Rate After Arthroscopic Rotator Cuff Repair.

    PubMed

    Cancienne, Jourdan M; Brockmeier, Stephen F; Rodeo, Scott A; Werner, Brian C

    2017-11-01

    Recent animal studies have demonstrated that hyperlipidemia is associated with poor tendon-bone healing after rotator cuff repair; however, these findings have not been substantiated in human studies. To examine any association between hyperlipidemia and the failure of arthroscopic rotator cuff repair requiring revision surgery and to investigate whether the use of statin lipid-lowering agents had any influence on observed associations. Cohort study; Level of evidence, 3. From a national insurance database, patients who underwent arthroscopic rotator cuff repair with perioperative lipid levels (total cholesterol, low-density lipoprotein [LDL], and triglycerides) recorded were reviewed. For each lipid test, patients were stratified into normal, moderate, and high groups based on published standards. For the total cholesterol and LDL cohorts, a subgroup analysis of patients stratified by statin use was performed. The primary outcome measure was ipsilateral revision rotator cuff surgery, including revision repair or debridement. A logistic regression analysis controlling for patient demographics and comorbidities was utilized for comparison. There were 30,638 patients included in the study. The rate of revision rotator cuff surgery was significantly increased in patients with moderate (odds ratio [OR], 1.20; 95% CI, 1.03-1.40; P = .022) and high total cholesterol levels (OR, 1.36; 95% CI, 1.10-1.55; P = .006) compared with patients with normal total cholesterol levels perioperatively. Within each of these groups, patients without statin use had significantly higher rates of revision surgery, while those with statin prescriptions did not. The absolute risk reduction for statin use ranged from 0.24% to 1.87% when stratified by the total cholesterol level, yielding a number needed to treat from 54 to 408 patients. The rate of revision surgery was significantly increased in patients with moderate (OR, 1.24; 95% CI, 1.10-1.41; P = .001) and high LDL levels (OR, 1.46; 95% CI, 1.08-1.99; P = .014) compared with patients with normal LDL levels perioperatively. Again, patients without statin prescriptions had significantly increased rates of revision surgery, whereas patients with statin use did not. The absolute risk reduction for statin use ranged from 0.26% to 1.89% when stratified by the LDL level, yielding a number needed to treat from 53 to 387 patients. There were no significant differences in the rates of revision rotator cuff surgery between patients with moderate and high triglyceride levels compared with patients with normal triglyceride levels. The present study found a significant association between moderate and high perioperative total cholesterol and LDL levels and the rate of revision surgery after primary arthroscopic rotator cuff repair. Furthermore, the use of statin agents appeared to mitigate the need for revision rotator cuff repair. Further prospective studies are necessary to validate these preliminary findings and determine if better perioperative lipid control can improve clinical outcomes after arthroscopic rotator cuff repair.

  8. Longitudinal Long-term Magnetic Resonance Imaging and Clinical Follow-up After Single-Row Arthroscopic Rotator Cuff Repair: Clinical Superiority of Structural Tendon Integrity.

    PubMed

    Heuberer, Philipp R; Smolen, Daniel; Pauzenberger, Leo; Plachel, Fabian; Salem, Sylvia; Laky, Brenda; Kriegleder, Bernhard; Anderl, Werner

    2017-05-01

    The number of arthroscopic rotator cuff surgeries is consistently increasing. Although generally considered successful, the reported number of retears after rotator cuff repair is substantial. Short-term clinical outcomes are reported to be rarely impaired by tendon retears, whereas to our knowledge, there is no study documenting long-term clinical outcomes and tendon integrity after arthroscopic rotator cuff repair. To investigate longitudinal long-term repair integrity and clinical outcomes after arthroscopic rotator cuff reconstruction. Case series; Level of evidence, 4. Thirty patients who underwent arthroscopic rotator cuff repair with suture anchors for a full-tendon full-thickness tear of the supraspinatus or a partial-tendon full-thickness tear of the infraspinatus were included. Two and 10 years after initial arthroscopic surgery, tendon integrity was analyzed using magnetic resonance imaging (MRI). The University of California, Los Angeles (UCLA) score and Constant score as well as subjective questions regarding satisfaction with the procedure and return to normal activity were used to evaluate short- and long-term outcomes. At the early MRI follow-up, 42% of patients showed a full-thickness rerupture, while 25% had a partial rerupture, and 33% of tendons remained intact. The 10-year MRI follow-up (129 ± 11 months) showed 50% with a total rerupture, while the other half of the tendons were partially reruptured (25%) or intact (25%). The UCLA and Constant scores significantly improved from preoperatively (UCLA total: 50.6% ± 20.2%; Constant total: 44.7 ± 10.5 points) to 2 years (UCLA total: 91.4% ± 16.0% [ P < .001]; Constant total: 87.8 ± 15.3 points [ P < .001]) and remained significantly higher after 10 years (UCLA total: 89.7% ± 15.9% [ P < .001]; Constant total: 77.5 ± 15.6 points [ P < .001]). The Constant total score and Constant strength subscore, but not the UCLA score, were also significantly better at 10 years postoperatively in patients with intact tendons compared with patients with retorn tendons (Constant total: 89.0 ± 7.8 points vs 75.7 ± 14.1 points, respectively [ P = .034]; Constant strength: 18.0 ± 4.9 points vs 9.2 ± 5.2 points, respectively [ P = .006]). The majority of patients rated their satisfaction with the procedure as "excellent" (83.3%), and 87.5% returned to their normal daily activities. Arthroscopic rotator cuff repair showed good clinical long-term results despite a high rate of retears. Nonetheless, intact tendons provided significantly superior clinical long-term outcomes, making the improvement of tendon healing and repair integrity important goals of future research efforts.

  9. [Effects of different crop rotations on growth of continuous cropping sorghum and its rhizosphere soil micro-environment.

    PubMed

    Wang, Jin Song; Fan, Fang Fang; Guo, Jun; Wu, Ai Lian; Dong, Er Wei; Bai, Wen Bin; Jiao, Xiao Yan

    2016-07-01

    The effects of crop rotation on sorghum [Sorghum biocolor (L) Moench] growth, rhizosphere microbial community and the activity of soil enzymes for successive crops of sorghum were evaluated. Five years of continuous monoculture sorghum as the control (CK) was compared to alfalfa and scallion planted in the fourth year. The results showed that incorporation of alfalfa and scallion into the rotation significantly improved sorghum shoot growth. Specifically, sorghum grain yield increased by 16.5% in the alfalfa rotation plots compared to the CK. The rotations also increased sorghum root system growth, with alfalfa or scallion rotation increasing sorghum total root length by 0.3 and 0.4 times, total root surface area by 0.6 and 0.5 times, root volume by 1.2 and 0.6 times, and root biomass by 1.0 and 0.3 times, respectively. Alfalfa rotation also expanded sorghum root distribution below the 10 cm soil depth. A Biolog analysis on biome functions in the sorghum flowering period indicated significantly higher microbial activity in the rotation plots. The alfalfa and scallion rotation increased the Shannon index by 0.2 and 0.1 times compared to the CK, and improved the sucrose activity in the rhizosphere soil. It was concluded that including alfalfa in rotation with sorghum improved sorghum rhizosphere soil environment, enhanced soil microbial enzyme activity, alleviated the obstacle of continuous cropping and thus increased the sorghum yield.

  10. Analysis of Iliac Artery Geometric Properties in Fenestrated Aortic Stent Graft Rotation.

    PubMed

    Doyle, Matthew G; Crawford, Sean A; Osman, Elrasheed; Eisenberg, Naomi; Tse, Leonard W; Amon, Cristina H; Forbes, Thomas L

    2018-04-01

    A complication of fenestrated endovascular aneurysm repair is the potential for stent graft rotation during deployment causing fenestration misalignment and branch artery occlusion. The objective of this study is to demonstrate that this rotation is caused by a buildup of rotational energy as the device is delivered through the iliac arteries and to quantify iliac artery geometric properties associated with device rotation. A retrospective clinical study was undertaken in which iliac artery geometric properties were assessed from preoperative imaging for 42 cases divided into 2 groups: 27 in the nonrotation group and 15 in the rotation group. Preoperative computed tomography scans were segmented, and the iliac artery centerlines were determined. Iliac artery tortuosity, curvature, torsion, and diameter were calculated from the centerline and the segmented vessel geometry. The total iliac artery net torsion was found to be higher in the rotation group compared to the nonrotation group (23.5 ± 14.7 vs 14.6 ± 12.8 mm -1 ; P = .05). No statistically significant differences were found for the mean values of tortuosity, curvature, torsion, or diameter between the 2 groups. Stent graft rotation occurred in 36% of the cases considered in this study. Cases with high iliac artery total net torsion were found to be more likely to have stent graft rotation upon deployment. This retrospective study provides a framework for prospectively studying the influence of iliac artery geometric properties on fenestrated stent graft rotation.

  11. Design and Functional Validation of a Mechanism for Dual-Spinning CubeSats

    NASA Technical Reports Server (NTRS)

    Peters, Eric; Dave, Pratik; Kingsbury, Ryan; Marinan, Anne; Wise, Evan; Pong, Chris; Prinkey, Meghan; Cahoy, Kerri; Miller, David W.; Sklair, Devon

    2014-01-01

    The mission of the Micro-sized Microwave Atmospheric Satellite (MicroMAS) is to collect useful atmospheric images using a miniature passive microwave radiometer payload hosted on a low-cost CubeSat platform. In order to collect this data, the microwave radiometer payload must rotate to scan the ground-track perpendicular to the satellite's direction of travel. A custom motor assembly was developed to facilitate the rotation of the payload while allowing the spacecraft bus to remained fixed in the local-vertical, local-horizontal (LVLH) frame for increased pointing accuracy. This paper describes the mechanism used to enable this dual-spinning operation for CubeSats, and the lessons learned during the design, fabrication, integration, and testing phases of the mechanism's development lifecycle.

  12. Subsychronous vibration of multistage centrifugal compressors forced by rotating stall

    NASA Technical Reports Server (NTRS)

    Fulton, J. W.

    1987-01-01

    A multistage centrifugal compressor, in natural gas re-injection service on an offshore petroleum production platform, experienced subsynchronous vibrations which caused excessive bearing wear. Field performance testing correlated the subsynchronous amplitude with the discharge flow coefficient, demonstrating the excitation to be aerodynamic. Adding two impellers allowed an increase in the diffuser flow angle (with respect to tangential) to meet the diffuser stability criteria based on factory and field tests correlated using the theory of Senoo (for rotating stall in a vaneless diffuser). This modification eliminated all significant subsynchronous vibrations in field service, thus confirming the correctness of the solution. Other possible sources of aerodynamically induced vibrations were considered, but the judgment that those are unlikely has been confirmed by subsequent experience with other similar compressors.

  13. Multiple piece turbine rotor blade

    DOEpatents

    Kimmel, Keith D.; Plank, William L.

    2016-07-19

    A spar and shell turbine rotor blade with a spar and a tip cap formed as a single piece, the spar includes a bottom end with dovetail or fir tree slots that engage with slots on a top end of a root section, and a platform includes an opening on a top surface for insertion of the spar in which a shell made from an exotic high temperature resistant material is secured between the tip cap and the platform. The spar is tapered to form thinner walls at the tip end to further reduce the weight and therefore a pulling force due to blade rotation. The spar and tip cap piece is made from a NiAL material to further reduce the weight and the pulling force.

  14. Forces and pressures beneath the saddle during mounting from the ground and from a raised mounting platform.

    PubMed

    Geutjens, C A; Clayton, H M; Kaiser, L J

    2008-03-01

    The objective was to use an electronic pressure mat to measure and compare forces and pressures of the saddle on a horse's back when riders mounted from the ground and with the aid of a mounting platform. Ten riders mounted a horse three times each from the ground and from a 35 cm high mounting platform in random order. Total force (summation of forces over all 256 sensors) was measured and compared at specific points on the force-time curve. Total force was usually highest as the rider's right leg was swinging upwards and was correlated with rider mass. When normalized to rider mass, total force and peak pressure were significantly higher when mounting from the ground than from a raised platform (P<0.05). The area of highest pressure was on the right side of the withers in 97% of mounting efforts, confirming the importance of the withers in stabilizing the saddle during mounting.

  15. Relationship between Spatial Abilities, Mental Rotation and Functional Anatomy Learning

    ERIC Educational Resources Information Center

    Guillot, Aymeric; Champely, Stephane; Batier, Christophe; Thiriet, Patrice; Collet, Christian

    2007-01-01

    This study investigated the relationship between visuo-spatial representation, mental rotation (MR) and functional anatomy examination results. A total of 184 students completed the Group Embedded Figures Test (GEFT), Mental Rotation Test (MRT) and Gordon Test of Visual Imagery Control. The time spent on personal assignment was also considered.…

  16. Individual Differences in the Mental Rotation Skills of Turkish Prospective Teachers

    ERIC Educational Resources Information Center

    Turgut, Melih

    2015-01-01

    This study investigated the effects of gender, academic performance and preschool education on mental rotation skills among Turkish prospective teachers. A total of 525 undergraduate students (364 female) from a government university located in western Turkey completed the Mental Rotation Test (MRT). A three-way [2 (gender) × 5 (academic…

  17. ROTATING STARS FROM KEPLER OBSERVED WITH GAIA DR1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davenport, James R. A.

    2017-01-20

    Astrometric data from the recent Gaia Data Release 1 have been matched against the sample of stars from Kepler with known rotation periods. A total of 1299 bright rotating stars were recovered from the subset of Gaia sources with good astrometric solutions, most with temperatures above 5000 K. From these sources, 894 were selected as lying near the main sequence using their absolute G -band magnitudes. These main-sequence stars show a bimodality in their rotation period distribution, centered roughly around a 600 Myr rotation isochrone. This feature matches the bimodal period distribution found in cooler stars with Kepler , butmore » was previously undetected for solar-type stars due to sample contamination by subgiants. A tenuous connection between the rotation period and total proper motion is found, suggesting that the period bimodality is due to the age distribution of stars within ∼300 pc of the Sun, rather than a phase of rapid angular momentum loss. This work emphasizes the unique power for understanding stellar populations that is created by combining temporal monitoring from Kepler with astrometric data from Gaia .« less

  18. Rotating bouncing disks, tossing pizza dough, and the behavior of ultrasonic motors

    NASA Astrophysics Data System (ADS)

    Liu, Kuang-Chen; Friend, James; Yeo, Leslie

    2009-10-01

    Pizza tossing and certain forms of standing-wave ultrasonic motors (SWUMs) share a similar process for converting reciprocating input into continuous rotary motion. We show that the key features of this motion conversion process such as collision, separation and friction coupling are captured by the dynamics of a disk bouncing on a vibrating platform. The model shows that the linear or helical hand motions commonly used by pizza chefs and dough-toss performers for single tosses maximize energy efficiency and the dough’s airborne rotational speed; on the other hand, the semielliptical hand motions used for multiple tosses make it easier to maintain dough rotation at the maximum speed. The system’s bifurcation diagram and basins of attraction also provide a physical basis for understanding the peculiar behavior of SWUMs and provide a means to design them. The model is able to explain the apparently chaotic oscillations that occur in SWUMs and predict the observed trends in steady-state speed and stall torque as preload is increased.

  19. Rotating bouncing disks, tossing pizza dough, and the behavior of ultrasonic motors.

    PubMed

    Liu, Kuang-Chen; Friend, James; Yeo, Leslie

    2009-10-01

    Pizza tossing and certain forms of standing-wave ultrasonic motors (SWUMs) share a similar process for converting reciprocating input into continuous rotary motion. We show that the key features of this motion conversion process such as collision, separation and friction coupling are captured by the dynamics of a disk bouncing on a vibrating platform. The model shows that the linear or helical hand motions commonly used by pizza chefs and dough-toss performers for single tosses maximize energy efficiency and the dough's airborne rotational speed; on the other hand, the semielliptical hand motions used for multiple tosses make it easier to maintain dough rotation at the maximum speed. The system's bifurcation diagram and basins of attraction also provide a physical basis for understanding the peculiar behavior of SWUMs and provide a means to design them. The model is able to explain the apparently chaotic oscillations that occur in SWUMs and predict the observed trends in steady-state speed and stall torque as preload is increased.

  20. General circular velocity relation of a test particle in a 3D gravitational potential: application to the rotation curves analysis and total mass determination of UGC 8490 and UGC 9753

    NASA Astrophysics Data System (ADS)

    Repetto, P.; Martínez-García, E. E.; Rosado, M.; Gabbasov, R.

    2018-06-01

    In this paper, we derive a novel circular velocity relation for a test particle in a 3D gravitational potential applicable to every system of curvilinear coordinates, suitable to be reduced to orthogonal form. As an illustration of the potentiality of the determined circular velocity expression, we perform the rotation curves analysis of UGC 8490 and UGC 9753 and we estimate the total and dark matter mass of these two galaxies under the assumption that their respective dark matter haloes have spherical, prolate, and oblate spheroidal mass distributions. We employ stellar population synthesis models and the total H I density map to obtain the stellar and H I+He+metals rotation curves of both galaxies. The subtraction of the stellar plus gas rotation curves from the observed rotation curves of UGC 8490 and UGC 9753 generates the dark matter circular velocity curves of both galaxies. We fit the dark matter rotation curves of UGC 8490 and UGC 9753 through the newly established circular velocity formula specialized to the spherical, prolate, and oblate spheroidal mass distributions, considering the Navarro, Frenk, and White, Burkert, Di Cintio, Einasto, and Stadel dark matter haloes. Our principal findings are the following: globally, cored dark matter profiles Burkert and Einasto prevail over cuspy Navarro, Frenk, and White, and Di Cintio. Also, spherical/oblate dark matter models fit better the dark matter rotation curves of both galaxies than prolate dark matter haloes.

  1. Numerical Investigation of Vortex Generator Flow Control for External-Compression Supersonic Inlets

    NASA Astrophysics Data System (ADS)

    Baydar, Ezgihan

    Vortex generators (VGs) within external-compression supersonic inlets for Mach 1.6 were investigated to determine their ability to increase total pressure recovery and reduce total pressure distortion. Ramp and vane-type VGs were studied. The geometric factors of interest included height, length, spacing, angle-of-incidence, and positions upstream and downstream of the inlet terminal shock. The flow through the inlet was simulated numerically through the solution of the steady-state, Reynolds-averaged Navier-Stokes equations on multi-block, structured grids using the Wind-US flow solver. The inlet performance was characterized by the inlet total pressure recovery and the radial and circumferential total pressure distortion indices at the engine face. Previous research of downstream VGs in the low-boom supersonic inlet demonstrated improvement in radial distortion up to 24% while my work on external-compression supersonic inlets improved radial distortion up to 86%, which is significant. The design of experiments and statistical analysis methods were applied to quantify the effect of the geometric factors of VGs and search for optimal VG arrays. From the analysis, VG angle-of-incidence and VG height were the most influential factors in increasing total pressure recovery and reducing distortion. The study on the two-dimensional external-compression inlet determined which passive flow control devices, such as counter-rotating vanes or ramps, reduce high distortion levels and improve the health of the boundary layer, relative to the baseline. Downstream vanes demonstrate up to 21% improvement in boundary layer health and 86% improvement in radial distortion. Upstream vanes demonstrated up to 3% improvement in boundary layer health and 9% improvement in radial distortion. Ramps showed no improvement in boundary layer health and radial distortion. Micro-VGs were preferred for their reduced viscous drag and improvement in total pressure recovery at the AIP. Although traditional VGs energize the flow with stronger vortex structures compared to micro-VGs, the AIP is affected with overwhelming amounts of reduced and enhanced flow regions. In summary, vanes are exceptional in reducing radial distortion and improving the health of the boundary layer compared to the ramps. In the study of the STEX inlet, vane-type vortex generators were the preferred devices for boundary layer flow control. In the supersonic diffuser, co-rotating vane arrays and counter-rotating vane arrays did not show improvement. In the subsonic diffuser, co-rotating vane arrays with negative angles-of-incidence and counter-rotating vane arrays were exceptional in reducing radial distortion and improving total pressure recovery. Downstream co-rotating vanes demonstrated up to 41% improvement in radial distortion whereas downstream counter-rotating vanes demonstrated up to 73% improvement. For downstream counter-rotating vanes, a polynomial trend between VG height and radial distortion indicate that increasing VG height improves inlet distortion. In summary, downstream vanes are exceptional in improving total pressure recovery compared to upstream vanes.

  2. A Novel Fault Diagnosis Method for Rotating Machinery Based on a Convolutional Neural Network

    PubMed Central

    Yang, Tao; Gao, Wei

    2018-01-01

    Fault diagnosis is critical to ensure the safety and reliable operation of rotating machinery. Most methods used in fault diagnosis of rotating machinery extract a few feature values from vibration signals for fault diagnosis, which is a dimensionality reduction from the original signal and may omit some important fault messages in the original signal. Thus, a novel diagnosis method is proposed involving the use of a convolutional neural network (CNN) to directly classify the continuous wavelet transform scalogram (CWTS), which is a time-frequency domain transform of the original signal and can contain most of the information of the vibration signals. In this method, CWTS is formed by discomposing vibration signals of rotating machinery in different scales using wavelet transform. Then the CNN is trained to diagnose faults, with CWTS as the input. A series of experiments is conducted on the rotor experiment platform using this method. The results indicate that the proposed method can diagnose the faults accurately. To verify the universality of this method, the trained CNN was also used to perform fault diagnosis for another piece of rotor equipment, and a good result was achieved. PMID:29734704

  3. A Novel Fault Diagnosis Method for Rotating Machinery Based on a Convolutional Neural Network.

    PubMed

    Guo, Sheng; Yang, Tao; Gao, Wei; Zhang, Chen

    2018-05-04

    Fault diagnosis is critical to ensure the safety and reliable operation of rotating machinery. Most methods used in fault diagnosis of rotating machinery extract a few feature values from vibration signals for fault diagnosis, which is a dimensionality reduction from the original signal and may omit some important fault messages in the original signal. Thus, a novel diagnosis method is proposed involving the use of a convolutional neural network (CNN) to directly classify the continuous wavelet transform scalogram (CWTS), which is a time-frequency domain transform of the original signal and can contain most of the information of the vibration signals. In this method, CWTS is formed by discomposing vibration signals of rotating machinery in different scales using wavelet transform. Then the CNN is trained to diagnose faults, with CWTS as the input. A series of experiments is conducted on the rotor experiment platform using this method. The results indicate that the proposed method can diagnose the faults accurately. To verify the universality of this method, the trained CNN was also used to perform fault diagnosis for another piece of rotor equipment, and a good result was achieved.

  4. Opioid Rotation in Cancer Pain Treatment.

    PubMed

    Schuster, Michael; Bayer, Oliver; Heid, Florian; Laufenberg-Feldmann, Rita

    2018-03-02

    Rotating several different WHO level III opioid drugs is a therapeutic option for patients with chronic cancer-related pain who suffer from inadequate analgesia and/or intolerable side effects. The evidence favoring opioid rotation is controversial, and the current guidelines in Germany and other countries contain only weak recommendations for it. This review is based on pertinent publications retrieved by a systematic review of the literature on opioid rotation for adult patients with chronic cancerrelated pain who are regularly taking WHO level III opioids by the oral or trans - dermal route. 9 individual studies involving a total of 725 patients were included in the analysis, and 3 previous systematic reviews of studies involving a total of 2296 patients were also analyzed. Morphine, oxycodone, fentanyl, hydromorphone, and buprenorphine were used as first-line opioid drugs, and hydromorphone, bupre - norphine, tapentadol, fentanyl, morphine, oxymorphone, and methadone were used as second-line opioid drugs. In all of the studies, pain control was achieved for 14 days after each rotation. In most of them, the dose of the new drug introduced in each rotation needed to be increased above the dose initially calculated from a rotation ratio, with the exception of rotations to methadone. The frequency of side effects was only rarely lessened, but patients largely considered the result of opioid rotation to be positive. No particular opioid drug was found to be best. Opioid rotation can improve analgesia and patient satisfaction. The success of opioid rotation appears to depend on the magnitude of the initial dose, among other factors. Tables of equianalgesic doses should be considered no more than a rough guide for determining the dose of the new drug. Rotations to methadone should be carried out under clinical supervision in experienced hands.

  5. Do modern total knee replacements improve tibial coverage?

    PubMed

    Meier, Malin; Webb, Jonathan; Collins, Jamie E; Beckmann, Johannes; Fitz, Wolfgang

    2018-01-25

    The purpose of the present study is to compare newer designs of various symmetric and asymmetric tibial components and measure tibial bone coverage using the rotational safe zone defined by two commonly utilized anatomic rotational landmarks. Computed tomography scans (CT scans) of one hundred consecutive patients scheduled for total knee arthroplasty were obtained pre-operatively. A virtual proximal tibial cut was performed and two commonly used rotational axes were added for each image: the medio-lateral axis (ML-axis) and the medial 1/3 tibial tubercle axis (med-1/3-axis). Different symmetric and asymmetric implant designs were then superimposed in various rotational positions for best cancellous and cortical coverage. The images were imported to a public domain imaging software, and cancellous and cortical bone coverage was computed for each image, with each implant design in various rotational positions. One single implant type could not be identified that provided the best cortical and cancellous coverage of the tibia, irrespective of using the med-1/3-axis or the ML-axis for rotational alignment. However, it could be confirmed that the best bone coverage was dependent on the selected rotational landmark. Furthermore, improved bone coverage was observed when tibial implant positions were optimized between the two rotational axes. Tibial coverage is similar for symmetric and asymmetric designs, but depends on the rotational landmark for which the implant is designed. The surgeon has the option to improve tibial coverage by optimizing placement between the two anatomic rotational alignment landmarks, the medial 1/3 and the ML-axis. Surgeons should be careful assessing intraoperative rotational tibial placement using the described anatomic rotational landmarks to optimize tibial bony coverage without compromising patella tracking. III.

  6. Optimization design about gimbal structure of high-precision autonomous celestial navigation tracking mirror system

    NASA Astrophysics Data System (ADS)

    Huang, Wei; Yang, Xiao-xu; Han, Jun-feng; Wei, Yu; Zhang, Jing; Xie, Mei-lin; Yue, Peng

    2016-01-01

    High precision tracking platform of celestial navigation with control mirror servo structure form, to solve the disadvantages of big volume and rotational inertia, slow response speed, and so on. It improved the stability and tracking accuracy of platform. Due to optical sensor and mirror are installed on the middle-gimbal, stiffness and resonant frequency requirement for high. Based on the application of finite element modality analysis theory, doing Research on dynamic characteristics of the middle-gimbal, and ANSYS was used for the finite element dynamic emulator analysis. According to the result of the computer to find out the weak links of the structure, and Put forward improvement suggestions and reanalysis. The lowest resonant frequency of optimization middle-gimbal avoid the bandwidth of the platform servo mechanism, and much higher than the disturbance frequency of carrier aircraft, and reduces mechanical resonance of the framework. Reaching provides a theoretical basis for the whole machine structure optimization design of high-precision of autonomous Celestial navigation tracking mirror system.

  7. MathWorks Simulink and C++ integration with the new VLT PLC-based standard development platform for instrument control systems

    NASA Astrophysics Data System (ADS)

    Kiekebusch, Mario J.; Di Lieto, Nicola; Sandrock, Stefan; Popovic, Dan; Chiozzi, Gianluca

    2014-07-01

    ESO is in the process of implementing a new development platform, based on PLCs, for upcoming VLT control systems (new instruments and refurbishing of existing systems to manage obsolescence issues). In this context, we have evaluated the integration and reuse of existing C++ libraries and Simulink models into the real-time environment of BECKHOFF Embedded PCs using the capabilities of the latest version of TwinCAT software and MathWorks Embedded Coder. While doing so the aim was to minimize the impact of the new platform by adopting fully tested solutions implemented in C++. This allows us to reuse the in house expertise, as well as extending the normal capabilities of the traditional PLC programming environments. We present the progress of this work and its application in two concrete cases: 1) field rotation compensation for instrument tracking devices like derotators, 2) the ESO standard axis controller (ESTAC), a generic model-based controller implemented in Simulink and used for the control of telescope main axes.

  8. Design and Proof-of-Concept Use of a Circular PMMA Platform with 16-Well Sample Capacity for Microwave-Accelerated Bioassays.

    PubMed

    Mohammed, Muzaffer; Aslan, Kadir

    2013-01-01

    We demonstrate the design and the proof-of-concept use of a new, circular poly(methyl methacrylate)-based bioassay platform (PMMA platform), which affords for the rapid processing of 16 samples at once. The circular PMMA platform (5 cm in diameter) was coated with a silver nanoparticle film to accelerate the bioassay steps by microwave heating. A model colorimetric bioassay for biotinylated albumin (using streptavidin-labeled horse radish peroxidase) was performed on the PMMA platform coated with and without silver nanoparticles (a control experiment), and at room temperature and using microwave heating. It was shown that the simulated temperature profile of the PMMA platform during microwave heating were comparable to the real-time temperature profile during actual microwave heating of the constructed PMMA platform in a commercial microwave oven. The model colorimetric bioassay for biotinylated albumin was successfully completed in ~2 min (total assay time) using microwave heating, as compared to 90 min at room temperature (total assay time), which indicates a ~45-fold decrease in assay time. Our PMMA platform design afforded for significant reduction in non-specific interactions and low background signal as compared to non-silvered PMMA surfaces when employed in a microwave-accelerated bioassay carried out in a conventional microwave cavity.

  9. Deficits in Glenohumeral Passive Range of Motion Increase Risk of Shoulder Injury in Professional Baseball Pitchers: A Prospective Study.

    PubMed

    Wilk, Kevin E; Macrina, Leonard C; Fleisig, Glenn S; Aune, Kyle T; Porterfield, Ron A; Harker, Paul; Evans, Timothy J; Andrews, James R

    2015-10-01

    Shoulder injuries from repetitive baseball pitching continue to be a serious, common problem. To determine whether passive range of motion of the glenohumeral joint was predictive of shoulder injury or shoulder surgery in professional baseball pitchers. Cohort study; Level of evidence, 2. Passive range of motion of the glenohumeral joint was assessed with a bubble goniometer during spring training for all major and minor league pitchers of a single professional baseball organization over a period of 8 successive seasons (2005-2012). Investigators performed a total of 505 examinations on 296 professional pitchers. Glenohumeral external and internal rotation was assessed with the pitcher supine and the arm abducted to 90° in the scapular plane with the scapula stabilized anteriorly at the coracoid process. Total rotation was defined as the sum of internal and external glenohumeral rotation. Passive shoulder flexion was measured with the pitcher supine and the lateral border of the scapula manually stabilized. After examination, shoulder injuries and injury durations were recorded by each pitcher's respective baseball organization and reported to the league as an injury transaction as each player was placed on the disabled list. Highly significant side-to-side differences were noted within subjects for each range of motion measurement. There were 75 shoulder injuries and 20 surgeries recorded among 51 pitchers, resulting in 5570 total days on the disabled list. Glenohumeral internal rotation deficit, total rotation deficit, and flexion deficit were not significantly related to shoulder injury or surgery. Pitchers with insufficient external rotation (<5° greater external rotation in the throwing shoulder) were 2.2 times more likely to be placed on the disabled list for a shoulder injury (P = .014; 95% CI, 1.2-4.1) and were 4.0 times more likely to require shoulder surgery (P = .009; 95% CI, 1.5-12.6). Insufficient shoulder external rotation on the throwing side increased the likelihood of shoulder injury and shoulder surgery. Sports medicine clinicians should be aware of these findings and develop a preventive plan that addresses this study's findings to reduce pitchers' risk of shoulder injury and surgery. © 2015 The Author(s).

  10. Platforms for hyperspectral imaging, in-situ optical and acoustical imaging in urbanized regions

    NASA Astrophysics Data System (ADS)

    Bostater, Charles R.; Oney, Taylor

    2016-10-01

    Hyperspectral measurements of the water surface of urban coastal waters are presented. Oblique bidirectional reflectance factor imagery was acquired made in a turbid coastal sub estuary of the Indian River Lagoon, Florida and along coastal surf zone waters of the nearby Atlantic Ocean. Imagery was also collected using a pushbroom hyperspectral imager mounted on a fixed platform with a calibrated circular mechatronic rotation stage. Oblique imagery of the shoreline and subsurface features clearly shows subsurface bottom features and rip current features within the surf zone water column. In-situ hyperspectral optical signatures were acquired from a vessel as a function of depth to determine the attenuation spectrum in Palm Bay. A unique stationary platform methodology to acquire subsurface acoustic images showing the presence of moving bottom boundary nephelometric layers passing through the acoustic fan beam. The acoustic fan beam imagery indicated the presence of oscillatory subsurface waves in the urbanized coastal estuary. Hyperspectral imaging using the fixed platform techniques are being used to collect hyperspectral bidirectional reflectance factor (BRF) measurements from locations at buildings and bridges in order to provide new opportunities to advance our scientific understanding of aquatic environments in urbanized regions.

  11. General view of the Aft Solid Rocket Motor Segment mated ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    General view of the Aft Solid Rocket Motor Segment mated with the Aft Skirt Assembly and External Tank Attach Ring in the Rotation Processing and Surge Facility at Kennedy Space Center and awaiting transfer to the Vehicle Assembly Building where it will be mounted onto the Mobile Launch Platform. - Space Transportation System, Solid Rocket Boosters, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX

  12. Active-Reserve Force Cost Model

    DTIC Science & Technology

    2015-01-01

    structure to be maintained for a given level of expenditure. We have developed this methodology and set of associated computer-based tools to...rotational, and deployed units or systems • Attain acceptable steady state operational or presence levels , as measured by the number of units a...at the community level . By community, we mean the set of units of a given type: mission, platform, or capability. We do this because AC-RC force-mix

  13. Symposium P: Three-Dimensional Architectures for Energy Generation and Storage

    DTIC Science & Technology

    2010-09-02

    anodic oxidation of aluminum to produce anodic aluminum oxide ( AAO ). The nanopores have diameters 15-100nm and depths 1-30um... aluminum oxide ( AAO ) template which can be successfully applied for fabrication of vertically aligned SiNWs. Then, we have investigated the electrical...performed in quiescent and rotating disc electrode (RDE) experiments. PSJfl Lateral Growth of Deep Nanopores in Anodic Aluminum Oxide as a Platform

  14. The Instrumented Frisbee(Registered TradeMark) as a Prototype for Planetary Entry Probes

    NASA Technical Reports Server (NTRS)

    Lorenz, Ralph D.

    2005-01-01

    A Frisbee has been equipped with sensors, batteries and micro-controllers for data acquisition to record its translational accelerations and attitude motion. The experiments explore the capabilities and limitations of sensors on a rapidly-rotating platform moving in air, and illustrate several of the complex gyrodynamic aspects of frisbee flight. The experiments constitute an instructive exercise in aerospace vehicle systems integration and in attitude reconstruction.

  15. The General Electric F404 - Engine of the RAAF’s New Fighter.

    DTIC Science & Technology

    1985-07-01

    turbine stages, high pressure and low pressure, stationary and rotating, are cooled, as well as rotors, cooling plates, blade and vane platforms and...such engine components as turbine rotor blading . disks and seals. This has led to the development of design methods that enable extended usage to...Scientific Adviser RAN Aircraft Maintenance and Flight Trials Unit Directorate of Naval Aircraft Engineering Directorate of Naval Aviation Policy

  16. Liquid crystal photonic bandgap fiber components

    NASA Astrophysics Data System (ADS)

    Scolari, L.; Alkeskjold, T. T.; Noordegraaf, D.; Tartarini, G.; Bassi, P.; Bjarklev, A.

    2007-11-01

    Liquid crystal photonic bandgap fibers represent a promising platform for the design of all-in-fiber optical devices, which show a high degree of tunability and exhibit novel optical properties for the manipulation of guided light. In this review paper we present tunable fiber devices for spectral filtering, such as Gaussian filters and notch filters, and devices for polarization control and analysis, such as birefringence control devices and switchable and rotatable polarizers.

  17. RMAIS: RFID-based medication Adherence Intelligence System.

    PubMed

    McCall, Corey; Maynes, Branden; Zou, Cliff C; Zhang, Ning J

    2010-01-01

    There has been compelling evidence that outpatients, especially those who are elderly or taking multiple complexly scheduled drugs, are not taking their medicines as directed, leading to unnecessary disease progression, complications, functional disabilities, lower quality of life, and even mortality. Existing technologies for monitoring and improving drug adherence are either costly or too complicated for general patients to use. In this paper, we introduce the detailed design and the complete prototype of a marketable Radio-Frequency Identification (RFID)-based Medication Adherence Intelligence System (RMAIS) that can be conveniently used at a residential home by ordinary patients. RMAIS is designed to maintain patients' independence and enable them to take multiple daily medicine dosages of the right amount at the right time. The system is patient-centered and user-friendly by reminding a patient of the prescribed time for medication and dispensing it in a fully automatic and fool-proof way. This is achieved mainly due to its novel design of a motorized rotation platform and the smooth integration of a scale, an RFID reader, and the rotation platform. In addition, this system has an Internet-based notification function that is used to alert the patient when it is time to take medicine as well as report deviations from the prescribed schedule to the primary care physicians or pharmacists.

  18. Calibration of a fluxgate magnetometer array and its application in magnetic object localization

    NASA Astrophysics Data System (ADS)

    Pang, Hongfeng; Luo, Shitu; Zhang, Qi; Li, Ji; Chen, Dixiang; Pan, Mengchun; Luo, Feilu

    2013-07-01

    The magnetometer array is effective for magnetic object detection and localization. Calibration is important to improve the accuracy of the magnetometer array. A magnetic sensor array built with four three-axis DM-050 fluxgate magnetometers is designed, which is connected by a cross aluminum frame. In order to improve the accuracy of the magnetometer array, a calibration process is presented. The calibration process includes magnetometer calibration, coordinate transformation and misalignment calibration. The calibration system consists of a magnetic sensor array, a GSM-19T proton magnetometer, a two-dimensional nonmagnetic rotation platform, a 12 V-dc portable power device and two portable computers. After magnetometer calibration, the RMS error has been decreased from an original value of 125.559 nT to a final value of 1.711 nT (a factor of 74). After alignment, the RMS error of misalignment has been decreased from 1322.3 to 6.0 nT (a factor of 220). Then, the calibrated array deployed on the nonmagnetic rotation platform is used for ferromagnetic object localization. Experimental results show that the estimated errors of X, Y and Z axes are -0.049 m, 0.008 m and 0.025 m, respectively. Thus, the magnetometer array is effective for magnetic object detection and localization in three dimensions.

  19. A mock heart engineered with helical aramid fibers for in vitro cardiovascular device testing.

    PubMed

    Jansen-Park, So-Hyun; Hsu, Po-Lin; Müller, Indra; Steinseifer, Ulrich; Abel, Dirk; Autschbach, Rüdiger; Rossaint, Rolf; Schmitz-Rode, Thomas

    2017-04-01

    Mock heart circulation loops (MHCLs) serve as in-vitro platforms to investigate the physiological interaction between circulatory systems and cardiovascular devices. A mock heart (MH) engineered with silicone walls and helical aramid fibers, to mimic the complex contraction of a natural heart, has been developed to advance the MHCL previously developed in our group. A mock aorta with an anatomical shape enables the evaluation of a cannulation method for ventricular assist devices (VADs) and investigation of the usage of clinical measurement systems like pressure-volume catheters. Ventricle and aorta molds were produced based on MRI data and cast with silicone. Aramid fibers were layered in the silicone ventricle to reproduce ventricle torsion. A rotating hollow shaft was connected to the apex enabling the rotation of the MH and the connection of a VAD. Silicone wall thickness, aramid fiber angle and fiber pitch were varied to generate different MH models. All MH models were placed in a tank filled with variable amounts of water and air simulating the compliance. In this work, physiological ventricular torsion angles (15°-26°) and physiological pressure-volume loops were achieved. This MHCL can serve as a comprehensive testing platform for cardiovascular devices, such as artificial heart valves and cannulation of VADs.

  20. Real-time mandibular angle reduction surgical simulation with haptic rendering.

    PubMed

    Wang, Qiong; Chen, Hui; Wu, Wen; Jin, Hai-Yang; Heng, Pheng-Ann

    2012-11-01

    Mandibular angle reduction is a popular and efficient procedure widely used to alter the facial contour. The primary surgical instruments, the reciprocating saw and the round burr, employed in the surgery have a common feature: operating at a high-speed. Generally, inexperienced surgeons need a long-time practice to learn how to minimize the risks caused by the uncontrolled contacts and cutting motions in manipulation of instruments with high-speed reciprocation or rotation. A virtual reality-based surgical simulator for the mandibular angle reduction was designed and implemented on a CUDA-based platform in this paper. High-fidelity visual and haptic feedbacks are provided to enhance the perception in a realistic virtual surgical environment. The impulse-based haptic models were employed to simulate the contact forces and torques on the instruments. It provides convincing haptic sensation for surgeons to control the instruments under different reciprocation or rotation velocities. The real-time methods for bone removal and reconstruction during surgical procedures have been proposed to support realistic visual feedbacks. The simulated contact forces were verified by comparing against the actual force data measured through the constructed mechanical platform. An empirical study based on the patient-specific data was conducted to evaluate the ability of the proposed system in training surgeons with various experiences. The results confirm the validity of our simulator.

  1. Effects of a Short-Duration Stretching Drill After Pitching on Elbow and Shoulder Range of Motion in Professional Baseball Pitchers.

    PubMed

    Escamilla, Rafael F; Yamashiro, Kyle; Mikla, Tony; Collins, Jeff; Lieppman, Keith; Andrews, James R

    2017-03-01

    A glenohumeral internal rotation (IR) deficit or a total rotational motion (IR plus external rotation [ER]) deficit in the throwing shoulder compared with the nonthrowing shoulder has been shown to increase the risk of shoulder and elbow injuries. After a pitching session, both IR and total rotational motion deficits have been shown to occur naturally for an extended period of time in asymptomatic pitchers, but it is unclear how to best control these deficits between pitching sessions. Purpose/Hypothesis: The purpose of this study was to determine whether performing a short-duration stretching/calisthenics drill after pitching will result in an increase in IR, ER, total rotational motion, and elbow extension in professional baseball pitchers. It was hypothesized that these shoulder and elbow passive range of motion (PROM) measurements would all decrease after pitching but would subsequently return to prepitching values after the short-duration stretching/calisthenics drill. Controlled laboratory study. A convenience sample of 20 male professional baseball pitchers served as study participants. The following sequence of activities was performed for all participants: (1) a 5- to 10-minute dynamic warm-up consisting of running and light throwing, (2) elbow extension and IR and ER PROM measurements taken before pitching, (3) 40 full-effort pitches off the pitching mound, (4) 8 minutes of rest, (5) elbow extension and IR and ER PROM measurements taken after pitching, (6) a short-duration stretching/calisthenics drill (two-out drill), and (7) elbow extension and IR and ER PROM measurements taken after the two-out drill. A 1-way repeated-measures analysis of variance ( P < .05) was employed to assess differences in elbow extension, IR, ER, and total rotational motion in the 3 measurement conditions (prepitching, postpitching, and postdrill). To assess intrarater and interrater reliability, intraclass correlation coefficients (ICCs) were calculated, and the measurement error was calculated using the standard error of measurement (SEM). Significant differences were observed among the 3 conditions for ER ( P = .002), IR ( P = .027), and total rotational motion ( P < .001), but there was no significant difference in elbow extension ( P = .117). Bonferroni post hoc analyses revealed (1) significantly greater ER during prepitching and postdrill versus the postpitching condition (94° ± 7° [prepitching] and 94° ± 8° [postdrill] vs 88° ± 8°; P = .010 and .005, respectively), (2) significantly greater IR during prepitching and postdrill versus the postpitching condition (36° ± 10° [prepitching] and 35° ± 9° [postdrill] vs 30° ± 10°; P = .034 and .043, respectively), and (3) significantly greater total rotational motion during prepitching and postdrill versus the postpitching condition (129° ± 13° [prepitching] and 129° ± 13° [postdrill] vs 119° ± 13°; P = .034 and .004, respectively). There were no significant differences in ER, IR, or total rotational motion between the prepitching and postdrill conditions ( P > .999 for all). The intrarater reliability (ICC 3,1 ) was 0.91 for ER (SEM, 1.3°) and 0.90 for IR (SEM, 1.9°), and the interrater reliability (ICC 2,1 ) was 0.81 for ER (SEM, 3.3°) and 0.77 for IR (SEM, 4.3°). After a 40-pitch bullpen session, IR and ER PROM as well as total rotational motion were significantly lower than prepitching values; however, these deficits were restored back to their prepitching levels after the players performed the two-out drill, which may increase pitching performance and decrease the risk of shoulder and elbow injuries. More research is needed to test these hypotheses and assess the clinical efficacy of the two-out drill. The findings from the current study will assist clinicians better understand the positive effects of performing a short duration stretching/calisthenics drill on shoulder internal and external rotation range of motion between innings while pitching during a baseball game.

  2. Concentration and characterization of airborne particles in Tehran's subway system.

    PubMed

    Kamani, Hosein; Hoseini, Mohammad; Seyedsalehi, Mahdi; Mahdavi, Yousef; Jaafari, Jalil; Safari, Gholam Hosein

    2014-06-01

    Particulate matter is an important air pollutant, especially in closed environments like underground subway stations. In this study, a total of 13 elements were determined from PM10 and PM2.5 samples collected at two subway stations (Imam Khomeini and Sadeghiye) in Tehran's subway system. Sampling was conducted in April to August 2011 to measure PM concentrations in platform and adjacent outdoor air of the stations. In the Imam Khomeini station, the average concentrations of PM10 and PM2.5 were 94.4 ± 26.3 and 52.3 ± 16.5 μg m(-3) in the platform and 81.8 ± 22.2 and 35 ± 17.6 μg m(-3) in the outdoor air, respectively. In the Sadeghiye station, mean concentrations of PM10 and PM2.5 were 87.6 ± 23 and 41.3 ± 20.4 μg m(-3) in the platform and 73.9 ± 17.3 and 30 ± 15 μg m(-3), in the outdoor air, respectively. The relative contribution of elemental components in each particle fraction were accounted for 43% (PM10) and 47.7% (PM2.5) in platform of Imam Khomeini station and 15.9% (PM10) and 18.5% (PM2.5) in the outdoor air of this station. Also, at the Sadeghiye station, each fraction accounted for 31.6% (PM10) and 39.8% (PM2.5) in platform and was 11.7% (PM10) and 14.3% (PM2.5) in the outdoor. At the Imam Khomeini station, Fe was the predominant element to represent 32.4 and 36 % of the total mass of PM10 and PM2.5 in the platform and 11.5 and 13.3% in the outdoor, respectively. At the Sadeghiye station, this element represented 22.7 and 29.8% of total mass of PM10 and PM2.5 in the platform and 8.7 and 10.5% in the outdoor air, respectively. Other major crustal elements were 5.8% (PM10) and 5.3% (PM2.5) in the Imam Khomeini station platform and 2.3 and 2.4% in the outdoor air, respectively. The proportion of other minor elements was significantly lower, actually less than 7% in total samples, and V was the minor concentration in total mass of PM10 and PM2.5 in both platform stations.

  3. Use of a nesting platform by Gull-billed Terns and Black Skimmers at the Salton Sea, California

    USGS Publications Warehouse

    Molina, Kathy C.; Ricca, Mark A.; Miles, A. Keith; Schoneman, Christian

    2009-01-01

    In 2006, we constructed an elevated nesting platform at the Salton Sea, California, and monitored its use by Gull-billed Terns and Black Skimmers over three subsequent breeding seasons. Black Skimmers were the first to colonize the platform with a total of five nests in 2006. In 2007 Gull-billed Terns colonized the platform with a total of 28 nests and the number of Black Skimmer nests increased to 20. Neither species nested on the platform in 2008. Low success for both species was probably influenced by at least two factors. First, when both species nested on the platform, nest densities were higher than is typical of their colonies on larger, earthen islands, and colony success may have been reduced by overcrowding. Second, lack of access to water may have reduced chicks' ability to thermoregulate effectively in the hot environment of the Salton Sea. Refinements to the size, design, and location of artificial nesting habitats are necessary to enhance productivity of colonial groundnesting birds at the Salton Sea successfully.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, J; Nguyen, D; O’Brien, R

    Purpose: Kilovoltage intrafraction monitoring (KIM) scheme has been successfully used to simultaneously monitor 3D tumor motion during radiotherapy. Recently, an iterative closest point (ICP) algorithm was implemented in KIM to also measure rotations about three axes, enabling real-time tracking of tumor motion in six degrees-of-freedom (DoF). This study aims to evaluate the accuracy of the six DoF motion estimates of KIM by comparing it with the corresponding motion (i) measured by the Calypso; and (ii) derived from kV/MV triangulation. Methods: (i) Various motions (static and dynamic) were applied to a CIRS phantom with three embedded electromagnetic transponders (Calypso Medical) usingmore » a 5D motion platform (HexaMotion) and a rotating treatment couch while both KIM and Calypso were used to concurrently track the phantom motion in six DoF. (ii) KIM was also used to retrospectively estimate six DoF motion from continuous sets of kV projections of a prostate, implanted with three gold fiducial markers (2 patients with 80 fractions in total), acquired during the treatment. Corresponding motion was obtained from kV/MV triangulation using a closed form least squares method based on three markers’ positions. Only the frames where all three markers were present were used in the analysis. The mean differences between the corresponding motion estimates were calculated for each DoF. Results: Experimental results showed that the mean of absolute differences in six DoF phantom motion measured by Calypso and KIM were within 1.1° and 0.7 mm. kV/MV triangulation derived six DoF prostate tumor better agreed with KIM estimated motion with the mean (s.d.) difference of up to 0.2° (1.36°) and 0.2 (0.25) mm for rotation and translation, respectively. Conclusion: These results suggest that KIM can provide an accurate six DoF intrafraction tumor during radiotherapy.« less

  5. Soil total carbon and crop yield affected by crop rotation and cultural practice

    USDA-ARS?s Scientific Manuscript database

    Stacked crop rotation and improved cultural practice have been used to control pests, but their impact on soil organic C (SOC) and crop yield are lacking. We evaluated the effects of stacked vs. alternate-year rotations and cultural practices on SOC at the 0- to 125-cm depth and annualized crop yiel...

  6. Optimization and testing of solid thin film lubrication deposition processes

    NASA Astrophysics Data System (ADS)

    Danyluk, Michael J.

    A novel method for testing solid thin films in rolling contact fatigue (RCF) under ultra-high vacuum (UHV) and high rotational speeds (130 Hz) is presented in this thesis. The UHV-RCF platform is used to quantify the adhesion and lubrication aspects of two thin film coatings deposited on ball-bearings using a physical vapor deposition ion plating process. Plasma properties during ion plating were measured using a Langmuir probe and there is a connection between ion flux, film stress, film adhesion, process voltage, pressure, and RCF life. The UHV-RCF platform and vacuum chamber were constructed using off-the-shelf components and 88 RCF tests in high vacuum have been completed. Maximum RCF life was achieved by maintaining an ion flux between 10 13 to 1015 (cm-2 s-1) with a process voltage and pressure near 1.5 kV and 15 mTorr. Two controller schemes were investigated to maintain optimal plasma conditions for maximum RCF life: PID and LQR. Pressure disturbances to the plasma have a detrimental effect on RCF life. Control algorithms that mitigate pressure and voltage disturbances already exist. However, feedback from the plasma to detect disturbances has not been explored related to deposition processes in the thin-film science literature. Manometer based pressure monitoring systems have a 1 to 2 second delay time and are too slow to detect common pressure bursts during the deposition process. Plasma diagnostic feedback is much faster, of the order of 0.1 second. Plasma total-current feedback was used successfully to detect a typical pressure disturbance associated with the ion plating process. Plasma current is related to ion density and process pressure. A real-time control application was used to detect the pressure disturbance by monitoring plasma-total current and converting it to feedback-input to a pressure control system. Pressure overshoot was eliminated using a nominal PID controller with feedback from a plasma-current diagnostic measurement tool.

  7. Anterior stability of the reverse shoulder arthroplasty depending on implant configuration and rotator cuff condition.

    PubMed

    Pastor, Marc-Frederic; Kraemer, Manuel; Wellmann, Mathias; Hurschler, Christof; Smith, Tomas

    2016-11-01

    The aim of this study was to investigate the stabilizing influence of the rotator cuff as well as the importance of glenosphere and onlay configuration on the anterior stability of the reverse total shoulder replacement (RTSR). A reverse total shoulder replacement was implanted into eight human cadaveric shoulders, and biomechanical testing was performed under three conditions: after implantation of the RTSR, after additional dissection of the subscapularis tendon, and after additional dissection of the infraspinatus and teres minor tendon. Testing was performed in 30° of abduction and three rotational positions: 30° internal rotation, neutral rotation, and 30° external rotation. Furthermore, the 38-mm and 42-mm glenospheres were tested in combination with a standard and a high-mobility humeral onlay. A gradually increased force was applied to the glenohumeral joint in anterior direction until the RTSR dislocated. The 42-mm glenosphere showed superior stability compared with the 38-mm glenosphere. The standard humeral onlay required significantly higher anterior dislocation forces than the more shallow high-mobility onlay. External rotation was the most stable position. Furthermore, isolated detachment of the subscapularis and combined dissection of the infraspinatus, teres minor, and subscapularis tendon increased anterior instability. This study showed superior stability with the 42-mm glenosphere and the more conforming standard onlay. External rotation was the most stable position. Detachment of the subscapularis as well as dissection of the complete rotator cuff decreased anterior stability.

  8. Calibration of gyro G-sensitivity coefficients with FOG monitoring on precision centrifuge

    NASA Astrophysics Data System (ADS)

    Lu, Jiazhen; Yang, Yanqiang; Li, Baoguo; Liu, Ming

    2017-07-01

    The advantages of mechanical gyros, such as high precision, endurance and reliability, make them widely used as the core parts of inertial navigation systems (INS) utilized in the fields of aeronautics, astronautics and underground exploration. In a high-g environment, the accuracy of gyros is degraded. Therefore, the calibration and compensation of the gyro G-sensitivity coefficients is essential when the INS operates in a high-g environment. A precision centrifuge with a counter-rotating platform is the typical equipment for calibrating the gyro, as it can generate large centripetal acceleration and keep the angular rate close to zero; however, its performance is seriously restricted by the angular perturbation in the high-speed rotating process. To reduce the dependence on the precision of the centrifuge and counter-rotating platform, an effective calibration method for the gyro g-sensitivity coefficients under fiber-optic gyroscope (FOG) monitoring is proposed herein. The FOG can efficiently compensate spindle error and improve the anti-interference ability. Harmonic analysis is performed for data processing. Simulations show that the gyro G-sensitivity coefficients can be efficiently estimated to up to 99% of the true value and compensated using a lookup table or fitting method. Repeated tests indicate that the G-sensitivity coefficients can be correctly calibrated when the angular rate accuracy of the precision centrifuge is as low as 0.01%. Verification tests are performed to demonstrate that the attitude errors can be decreased from 0.36° to 0.08° in 200 s. The proposed measuring technology is generally applicable in engineering, as it can reduce the accuracy requirements for the centrifuge and the environment.

  9. A high resolution small animal radiation research platform (SARRP) with x-ray tomographic guidance capabilities

    PubMed Central

    Wong, John; Armour, Elwood; Kazanzides, Peter; Iordachita, Iulian; Tryggestad, Erik; Deng, Hua; Matinfar, Mohammad; Kennedy, Christopher; Liu, Zejian; Chan, Timothy; Gray, Owen; Verhaegen, Frank; McNutt, Todd; Ford, Eric; DeWeese, Theodore L.

    2008-01-01

    Purpose To demonstrate the CT imaging, conformal irradiation and treatment planning capabilities of a small animal radiation research platform (SARRP). Methods The SARRP employs a dual-focal spot, constant voltage x-ray source mounted on a gantry with a source-to-isocenter distance of 35 cm. Gantry rotation is limited to 120° from vertical. Eighty to 100 kVp x-rays from the smaller 0.4 mm focal spot are used for imaging. Both 0.4 mm and 3.0 mm focal spots operate at 225 kVp for irradiation. Robotic translate/rotate stages are used to position the animal. Cone-beam (CB) CT imaging is achieved by rotating the horizontal animal between the stationary x-ray source and a flat-panel detector. Radiation beams range from 0.5 mm in diameter to (60 × 60) mm2. Dosimetry is measured with radio-chromic films. Monte Carlo dose calculations are employed for treatment planning. The combination of gantry and robotic stage motions facilitate conformal irradiation. Results The SARRP spans 3 ft × 4 ft × 6 ft (WxLxH). Depending on filtration, the isocenter dose outputs at 1 cm depth in water range from 22 to 375 cGy/min from the smallest to the largest radiation fields. The 20% to 80% dose fall-off spans 0.16 mm. CBCT with (0.6 × 0.6 × 0.6) mm3 voxel resolution is acquired with less than 1 cGy. Treatment planning is performed at sub-mm resolution. Conclusions The capability of the SARRP to deliver highly focal beams to multiple animal model systems provides new research opportunities that more realistically bridge laboratory research and clinical translation. PMID:18640502

  10. SDSS-IV MaNGA: the different quenching histories of fast and slow rotators

    NASA Astrophysics Data System (ADS)

    Smethurst, R. J.; Masters, K. L.; Lintott, C. J.; Weijmans, A.; Merrifield, M.; Penny, S. J.; Aragón-Salamanca, A.; Brownstein, J.; Bundy, K.; Drory, N.; Law, D. R.; Nichol, R. C.

    2018-01-01

    Do the theorized different formation mechanisms of fast and slow rotators produce an observable difference in their star formation histories? To study this, we identify quenching slow rotators in the MaNGA sample by selecting those that lie below the star-forming sequence and identify a sample of quenching fast rotators that were matched in stellar mass. This results in a total sample of 194 kinematically classified galaxies, which is agnostic to visual morphology. We use u - r and NUV - u colours from the Sloan Digital Sky Survey and GALEX and an existing inference package, STARPY, to conduct a first look at the onset time and exponentially declining rate of quenching of these galaxies. An Anderson-Darling test on the distribution of the inferred quenching rates across the two kinematic populations reveals they are statistically distinguishable (3.2σ). We find that fast rotators quench at a much wider range of rates than slow rotators, consistent with a wide variety of physical processes such as secular evolution, minor mergers, gas accretion and environmentally driven mechanisms. Quenching is more likely to occur at rapid rates (τ ≲ 1 Gyr) for slow rotators, in agreement with theories suggesting slow rotators are formed in dynamically fast processes, such as major mergers. Interestingly, we also find that a subset of the fast rotators quench at these same rapid rates as the bulk of the slow rotator sample. We therefore discuss how the total gas mass of a merger, rather than the merger mass ratio, may decide a galaxy's ultimate kinematic fate.

  11. Attitude control for on-orbit servicing spacecraft using hybrid actuator

    NASA Astrophysics Data System (ADS)

    Wu, Yunhua; Han, Feng; Zheng, Mohong; He, Mengjie; Chen, Zhiming; Hua, Bing; Wang, Feng

    2018-03-01

    On-orbit servicing is one of the research hotspots of space missions. A small satellite equipped with multiple robotic manipulators is expected to carry out device replacement task for target large spacecraft. Attitude hyperstable control of a small satellite platform under rotations of the manipulators is a challenging problem. A hybrid momentum exchanging actuator consists of Control Moment Gyro (CMG) and Reaction Wheel (RW) is proposed to tackle the above issue, due to its huge amount of momentum storage capacity of the CMG and high control accuracy of the RW, in which the CMG produces large command torque while the RW offers additional control degrees. The constructed dynamic model of the servicing satellite advises that it's feasible for attitude hyperstable control of the platform with arbitrary manipulators through compensating the disturbance generated by rapid rotation of the manipulators. Then, null motion between the CMG and RW is exploited to drive the system to the expected target with favorable performance, and to overcome the CMG inherent geometric singularity and RW saturation. Simulations with different initial situations, including CMG hyperbolic and elliptic singularities and RW saturation, are executed. Compared to the scenarios where the CMG or RW fails stabilizing the platform, large control torque, precise control effect and escape of singularity are guaranteed by the introduced hybrid actuator, CMGRW (CMGRW refers to the hybrid momentum exchanging devices in this paper, consisting of 4 CMGs in classical pyramid cluster and 3 RWs in an orthogonal group (specific description can been found in Section 4)). The feasible performance of the satellite, CMG and RW under large disturbance demonstrates that the control architecture proposed is capable of attitude control for on-orbit servicing satellite with multiple robotic manipulators.

  12. Navigation-based tibial rotation at 90° of flexion is associated with better range of motion in navigated total knee arthroplasty.

    PubMed

    Ishida, Kazunari; Shibanuma, Nao; Matsumoto, Tomoyuki; Sasaki, Hiroshi; Takayama, Koji; Hiroshima, Yuji; Kuroda, Ryosuke; Kurosaka, Masahiro

    2016-08-01

    In clinical practice, people with better femorotibial rotation in the flexed position often achieve a favourable postoperative maximum flexion angle (MFA). However, no objective data have been reported to support this clinical observation. In the present study, we aimed to investigate the correlation between the amount of intraoperative rotation and the pre- and postoperative flexion angles. Fifty-five patients with varus osteoarthritis undergoing computer-assisted posterior-stabilized total knee arthroplasty (TKA) were enrolled. After registration, rotational stress was applied towards the knee joint, and the rotational angles were recorded by using a navigation system at maximum extension and 90° of flexion. After implantation, rotational stress was applied for a second time, and the angles were recorded once more. The MFA was measured before surgery and 1 month after surgery, and the correlation between the amount of femorotibial rotation during surgery and the MFA was statistically evaluated. Although the amount of tibial rotation at maximum extension was not correlated with the MFA, the amount of tibial rotation at 90° of flexion after registration was positively correlated with the pre- and postoperative MFA (both p < 0.005). However, no significant relationship was observed between the amount of tibial rotation after implantation and the postoperative MFA (n.s.). The results showed that better femorotibial rotation at 90° of flexion is associated with a favourable postoperative MFA, suggesting that the flexibility of the surrounding soft tissues is an important factor for obtaining a better MFA, which has important clinical relevance. Hence, further evaluation of navigation-based kinematics during TKA may provide useful information on MFA. Diagnostic studies, development of diagnostic criteria in a consecutive series of patients, and a universally applied "gold" standard, Level II.

  13. Comparisons of weed community, soil health and economic performance between wheat-maize and garlic-soybean rotation systems under different weed managements

    PubMed Central

    Muminov, Mahmud A.; Guo, Liyue; Song, Yanjie; Gu, Xian; Cen, Yu; Meng, Jie

    2018-01-01

    This study compared the impacts of different weed managements on weed community, soil health and economic performance between the wheat–maize (WM) and garlic–soybean (GS) rotations. A total of four treatments (H0T, tillage without herbicide; H0T0, without both herbicide and tillage; HT, both herbicide and tillage; HT0, herbicide without tillage) were designed for both rotations. A total of 16 weed species were recorded in the WM rotation, with life forms of 62% for annuals, 12% for annual + perennial and 20% for perennials. While in the GS rotation, there were 17 weed species, with 71% being annuals. When crop rotation changed from WM to GS, the topsoil layer seed bank (0–5 cm) decreased by 137%. GS rotation always had higher earthworm densities than that of WM under the same condition. Organic weed control (H0T, H0T0) from both WM and GS added more soil organic matters than the chemical methods (HT and HT0). Economically, up to 69% higher net profit had been achieved in the GS than WM for their organic products. This study provides an ecological basis to guide organic farming practices, especially for weed management in the future. PMID:29868258

  14. EFFECT OF CHERENKOV LIGHT POLARIZATION ON TOTAL REFLECTION COUNTER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowell, J.D.; Duteil, P.; Leontic, B.

    1963-01-01

    A rugged total internal reflection counter with a 3- to 5cm thick compact radiator was used at the CERN proton synchrotron for beam analysis. The threshold behavior of this counter was compared when filled with glycerol and with turpentine. Turpentine is optically active and rotates the plane of polarization about 7 un. Concent 85% /cm. Figures illustrate the effect of this polarization rotation. (A.G.W.)

  15. Three-Dimensional Root Phenotyping with a Novel Imaging and Software Platform1[C][W][OA

    PubMed Central

    Clark, Randy T.; MacCurdy, Robert B.; Jung, Janelle K.; Shaff, Jon E.; McCouch, Susan R.; Aneshansley, Daniel J.; Kochian, Leon V.

    2011-01-01

    A novel imaging and software platform was developed for the high-throughput phenotyping of three-dimensional root traits during seedling development. To demonstrate the platform’s capacity, plants of two rice (Oryza sativa) genotypes, Azucena and IR64, were grown in a transparent gellan gum system and imaged daily for 10 d. Rotational image sequences consisting of 40 two-dimensional images were captured using an optically corrected digital imaging system. Three-dimensional root reconstructions were generated and analyzed using a custom-designed software, RootReader3D. Using the automated and interactive capabilities of RootReader3D, five rice root types were classified and 27 phenotypic root traits were measured to characterize these two genotypes. Where possible, measurements from the three-dimensional platform were validated and were highly correlated with conventional two-dimensional measurements. When comparing gellan gum-grown plants with those grown under hydroponic and sand culture, significant differences were detected in morphological root traits (P < 0.05). This highly flexible platform provides the capacity to measure root traits with a high degree of spatial and temporal resolution and will facilitate novel investigations into the development of entire root systems or selected components of root systems. In combination with the extensive genetic resources that are now available, this platform will be a powerful resource to further explore the molecular and genetic determinants of root system architecture. PMID:21454799

  16. Late orogenic, large-scale rotations in the Tien Shan and adjacent mobile belts in Kyrgyzstan and Kazakhstan

    NASA Astrophysics Data System (ADS)

    Van der Voo, Rob; Levashova, Natalia M.; Skrinnik, Ludmila I.; Kara, Taras V.; Bazhenov, Mikhail L.

    2006-11-01

    Most of Kazakhstan belongs to the central part of the Eurasian Paleozoic mobile belts for which previously proposed tectonic scenarios have been rather disparate. Of particular interest is the origin of strongly curved Middle and Late Paleozoic volcanic belts of island-arc and Andean-arc affinities that dominate the structure of Kazakhstan. We undertook a paleomagnetic study of Carboniferous to Upper Permian volcanics and sediments from several localities in the Ili River basin between the Tien Shan and the Junggar-Alatau ranges in southeast Kazakhstan. Our main goal was to investigate the Permian kinematic evolution of these belts, particularly in terms of rotations about vertical axes, in the hope of deciphering the dynamics that played a role during the latest Paleozoic deformation in this area. This deformation, in turn, can then be related to the amalgamation of this area with Baltica, Siberia, and Tarim in the expanding Eurasian supercontinent. Thermal demagnetization revealed that most Permian rocks retained a pretilting and likely primary component, which is of reversed polarity at three localities and normal at the fourth. In contrast, most Carboniferous rocks are dominated by postfolding reversed overprints of probably "mid-Permian" age, whereas presumably primary components are isolated from a few sites at two localities. Mean inclinations of primary components generally agree with coeval reference values extrapolated from Baltica, whereas declinations from primary as well as secondary components are deflected counterclockwise (ccw) by up to ˜ 90°. Such ccw rotated directions have previously also been observed in other Tien Shan sampling areas and in the adjacent Tarim Block to the south. However, two other areas in Kazakhstan show clockwise (cw) rotations of Permian magnetization directions. One area is located in the Kendyktas block about 300 km to the west of the Ili River valley, and the other is found in the Chingiz Range, to the north of Lake Balkhash and about 400 km to the north of the Ili River valley. The timing of the ccw as well as cw rotations is clearly later than the disappearance of any marine basins from northern Tarim, the Tien Shan and eastern Kazakhstan, so that the rotations cannot be attributed to island-arc or Andean-margin plate settings — instead we attribute the rotations to large-scale, east-west (present-day coordinates), sinistral wrenching in an intracontinental setting, related to convergence between Siberia and Baltica, as recently proposed by Natal'in and Şengör [Natal'in, B.A., and Şengör, A.M.C., 2005. Late Palaeozoic to Triassic evolution of the Turan and Scythian platforms: the pre-history of the palaeo-Tethyan closure, Tectonophysics, 404, 175-202.]. Our previous work in the Chingiz and North Tien Shan areas on Ordovician and Silurian rocks suggested relative rotations of ˜ 180°, whereas the Permian declination differences are of the order of 90° between the two areas. Thus, we assume that about 50% of the total post-Ordovician rotations are of pre-Late Permian age, with the other half of Late Permian-earliest Mesozoic age. The pre-Late Permian rotations are likely related to oroclinal bending during plate boundary evolution in a supra-subduction setting, given the calc-alkaline character of nearly all of the pre-Late Permian volcanics in the strongly curved belts.

  17. Advanced Silicon Photonic Device Architectures for Optical Communications: Proposals and Demonstrations

    NASA Astrophysics Data System (ADS)

    Sacher, Wesley David

    Photonic integrated circuits implemented on silicon (Si) hold the potential for densely integrated electro-optic and passive devices manufactured by the high-volume fabrication and sophisticated assembly processes used for complementary metal-oxide-semiconductor (CMOS) electronics. However, high index contrast Si photonics has a number of functional limitations. In this thesis, several devices are proposed, designed, and experimentally demonstrated to overcome challenges in the areas of resonant modulation, waveguide loss, fiber-to-chip coupling, and polarization control. The devices were fabricated using foundry services at IBM and A*STAR Institute of Microelectronics (IME). First, we describe coupling modulated microrings, in which the coupler between a microring and the bus waveguide is modulated. The device circumvents the modulation bandwidth vs. resonator linewidth trade-off of conventional intracavity modulated microrings. We demonstrate a Si coupling modulated microring with a small-signal modulation response free of the parasitic resonator linewidth limitations at frequencies up to about 6x the linewidth. Comparisons of eye diagrams show that coupling modulation achieved data rates > 2x the rate attainable with intracavity modulation. Second, we demonstrate a silicon nitride (Si3N4)-on-Si photonic platform with independent Si3N4 and Si waveguides and taper transitions to couple light between the layers. The platform combines the excellent passive waveguide properties of Si3N4 and the compatibility of Si waveguides with electro-optic devices. Within the platform, we propose and demonstrate dual-level, Si3N 4-on-Si, fiber-to-chip grating couplers that simultaneously have wide bandwidths and high coupling efficiencies. Conventional Si and Si3N 4 grating couplers suffer from a trade-off between bandwidth and coupling efficiency. The dual-level grating coupler achieved a peak coupling efficiency of -1.3 dB and a 1-dB bandwidth of 80 nm, a record for the coupling efficiency-bandwidth product. Finally, we describe polarization rotator-splitters and controllers based on mode conversion between the fundamental transverse magnetic polarized mode and a high order transverse electric polarized mode in vertically asymmetric waveguides. We demonstrate the first polarization rotator-splitters and controllers that are fully compatible with standard active Si photonic platforms and extend the concept to our Si3N4-on-Si photonic platform.

  18. Rapid Assessment of Age-Related Differences in Standing Balance

    PubMed Central

    Kalisch, Tobias; Kattenstroth, Jan-Christoph; Noth, Sebastian; Tegenthoff, Martin; Dinse, Hubert R.

    2011-01-01

    As life expectancy continues to rise, in the future there will be an increasing number of older people prone to falling. Accordingly, there is an urgent need for comprehensive testing of older individuals to collect data and to identify possible risk factors for falling. Here we use a low-cost force platform to rapidly assess deficits in balance under various conditions. We tested 21 healthy older adults and 24 young adults during static stance, unidirectional and rotational displacement of their centre of pressure (COP). We found an age-related increase in postural sway during quiet standing and a reduction of maximal COP displacement in unidirectional and rotational displacement tests. Our data show that even low-cost computerized assessment tools allow for the comprehensive testing of balance performance in older subjects. PMID:21629742

  19. The high resolution submillimetre spectrum of the stratosphere

    NASA Technical Reports Server (NTRS)

    Carli, B.

    1984-01-01

    The structure of the stratospheric spectrum, measured with a resolution of 0.0033/cm unapodized in the 7-90/cm spectral interval is described. The spectra from measurements recorded on April 24, 1979 from a balloon-borne platform at about 39 km altitude launched from the National Scientific Balloon Facility of Palestine, TX are presented. The main spectroscopic constituents include a few strong and saturated lines due to the rotational spectrum of water vapor, to magnetic dipole transitions of oxygen, and to the rotational spectrum of ozone. It is shown that the lines of ozone prevent the positive identification of the contribution to the submillimeter spectrum of several minor constituents such as HF, HCl, HCN, HNO3, and N2O. The assignments which are possible in the spectra are revised.

  20. 76 FR 1192 - Standard on Powered Platforms for Building Maintenance; Extension of the Office of Management and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-07

    ...] Standard on Powered Platforms for Building Maintenance; Extension of the Office of Management and Budget's... specified in its Standard on Powered Platforms for Building Maintenance (29 CFR 1910.66). DATES: Comments... Building Maintenance (29 CFR 1910.66). The Agency is requesting to retain its current burden hour total of...

  1. Electrically-Generated Spin Polarization in Non-Magnetic Semiconductors

    DTIC Science & Technology

    2016-03-31

    resolved Faraday rotation data due to electron spin polarization from previous pump pulses was characterized, and an analytic solution for this phase...electron spin polarization was shown to produce nuclear hyperpolarization through dynamic nuclear polarization. Time-resolved Faraday rotation...Distribution approved for public release. 3    Figure 3. Total magnetic field measured using time-resolved Faraday rotation with the electrically

  2. IUE observations of the M dwarfs CM Draconis and Rossiter 137 B - Magnetic activity at saturated levels

    NASA Technical Reports Server (NTRS)

    Vilhu, O.; Brandenburg, A.; Ambruster, C. W.; Neff, J. E.; Linsky, J. L.

    1989-01-01

    IUE observations of two active M dwarfs with known rotation rate or age and presumed to be almost totally convective are presented. The first of these stars, CM Draconis (Gl 630.1), is an old Population II binary with its components in tidally induced rapid rotation (P = 1.27 d, dM 4 + dM 4). The other one, Rossiter 137 B, forms with HD 36705 (AB Dor) a visual pair of young active stars. The activity of CM Dra is due to the forced rotation in a close binary, while Rst 137 B is assumed to rotate fast enough to generate its magnetica activity. These results are compared with those for M dwarfs, particularly AU Mic and YZ CMi, that have known rotational periods and measured ultraviolet emission line fluxes. The chromospheric-coronal saturation levels of cool dwarfs between 0.3 less than B-V less than 1.6 is determined. It is found that saturated F stars have stronger chromospheres than saturated M stars, but the opposite is true for the corona. Results of these observations seem to favor a rotation-dependent distributed dynamo generating magnetic flux in totally convective stars.

  3. Large-scale HTS bulks for magnetic application

    NASA Astrophysics Data System (ADS)

    Werfel, Frank N.; Floegel-Delor, Uta; Riedel, Thomas; Goebel, Bernd; Rothfeld, Rolf; Schirrmeister, Peter; Wippich, Dieter

    2013-01-01

    ATZ Company has constructed about 130 HTS magnet systems using high-Tc bulk magnets. A key feature in scaling-up is the fabrication of YBCO melts textured multi-seeded large bulks with three to eight seeds. Except of levitation, magnetization, trapped field and hysteresis, we review system engineering parameters of HTS magnetic linear and rotational bearings like compactness, cryogenics, power density, efficiency and robust construction. We examine mobile compact YBCO bulk magnet platforms cooled with LN2 and Stirling cryo-cooler for demonstrator use. Compact cryostats for Maglev train operation contain 24 pieces of 3-seed bulks and can levitate 2500-3000 N at 10 mm above a permanent magnet (PM) track. The effective magnetic distance of the thermally insulated bulks is 2 mm only; the stored 2.5 l LN2 allows more than 24 h operation without refilling. 34 HTS Maglev vacuum cryostats are manufactured tested and operate in Germany, China and Brazil. The magnetic levitation load to weight ratio is more than 15, and by group assembling the HTS cryostats under vehicles up to 5 t total loads levitated above a magnetic track is achieved.

  4. KSC-98pc1179

    NASA Image and Video Library

    1998-09-28

    KENNEDY SPACE CENTER, FLA. -- At left, the payload canister for Space Shuttle Discovery is lifted from its canister movement vehicle to the top of the Rotating Service Structure on Launch Pad 39-B. Discovery (right), sitting atop the Mobile Launch Platform and next to the Fixed Service Structure (FSS), is scheduled for launch on Oct. 29, 1998, for the STS-95 mission. That mission includes the International Extreme Ultraviolet Hitchhiker (IEH-3), the Hubble Space Telescope Orbital Systems Test Platform, the Spartan solar-observing deployable spacecraft, and the SPACEHAB single module with experiments on space flight and the aging process. At the top of the FSS can be seen the 80-foot lightning mast . The 4-foot-high lightning rod on top helps prevent lightning current from passing directly through the Space Shuttle and the structures on the pad

  5. Novel liquid equilibrium valving on centrifugal microfluidic CD platform.

    PubMed

    Al-Faqheri, Wisam; Ibrahim, Fatimah; Thio, Tzer Hwai Gilbert; Arof, Hamzah; Madou, Marc

    2013-01-01

    One of the main challenges faced by researchers in the field of microfluidic compact disc (CD) platforms is the control of liquid movement and sequencing during spinning. This paper presents a novel microfluidic valve based on the principle of liquid equilibrium on a rotating CD. The proposed liquid equilibrium valve operates by balancing the pressure produced by the liquids in a source and a venting chamber during spinning. The valve does not require external forces or triggers, and is able to regulate burst frequencies with high accuracy. In this work, we demonstrate that the burst frequency can be significantly raised by making just a small adjustment of the liquid height in the vent chamber. Finally, the proposed valve ng method can be used separately or combined with other valving methods in advance microfluidic processes.

  6. The role of British Aerospace in satellite TV broadcasting

    NASA Astrophysics Data System (ADS)

    Blonstein, J. L.

    DBS spacecraft development (completed, underway, and planned) at British Aerospace is surveyed and illustrated with diagrams, graphs, drawings, maps, and tables. The satellites briefly characterized include OTS, ECS, Olympus, Eurostar, and Unisat. The growth in the number and power of DBS channels available is described, and the design concept of a 15-kW platform combining sun-pointing solar panels and outer structure with a slowly rotating earth-pointing inner antenna structure is presented.

  7. An additional reference axis improves femoral rotation alignment in image-free computer navigation assisted total knee arthroplasty.

    PubMed

    Inui, Hiroshi; Taketomi, Shuji; Nakamura, Kensuke; Sanada, Takaki; Tanaka, Sakae; Nakagawa, Takumi

    2013-05-01

    Few studies have demonstrated improvement in accuracy of rotational alignment using image-free navigation systems mainly due to the inconsistent registration of anatomical landmarks. We have used an image-free navigation for total knee arthroplasty, which adopts the average algorithm between two reference axes (transepicondylar axis and axis perpendicular to the Whiteside axis) for femoral component rotation control. We hypothesized that addition of another axis (condylar twisting axis measured on a preoperative radiograph) would improve the accuracy. One group using the average algorithm (double-axis group) was compared with the other group using another axis to confirm the accuracy of the average algorithm (triple-axis group). Femoral components were more accurately implanted for rotational alignment in the triple-axis group (ideal: triple-axis group 100%, double-axis group 82%, P<0.05). Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Immunohistochemistry practices of cytopathology laboratories: a survey of participants in the College of American Pathologists Nongynecologic Cytopathology Education Program.

    PubMed

    Fischer, Andrew H; Schwartz, Mary R; Moriarty, Ann T; Wilbur, David C; Souers, Rhona; Fatheree, Lisa; Booth, Christine N; Clayton, Amy C; Kurtyz, Daniel F I; Padmanabhan, Vijayalakshmi; Crothers, Barbara A

    2014-09-01

    Immunohistochemistry (IHC) is important for cytology but poses special challenges because preanalytic conditions may differ from the conditions of IHC-positive controls. To broadly survey cytology laboratories to quantify preanalytic platforms for cytology IHC and identify problems with particular platforms or antigens. To discover how validation guidelines for HER2 testing have affected cytology. A voluntary survey of cytology IHC practices was sent to 1899 cytology laboratories participating in the College of American Pathologists Nongynecologic Cytopathology Education Program in the fall of 2009. A total of 818 laboratories (43%) responded to the survey by April 2010. Three hundred fourty-five of 791 respondents (44%) performed IHC on cytology specimens. Seventeen different fixation and processing platforms prior to antibody reaction were reported. A total of 59.2% of laboratories reported differences between the platforms for cytology specimens and positive controls, but most (155 of 184; 84%) did not alter antibody dilutions or antigen retrieval for cytology IHC. When asked to name 2 antibodies for which staining conditions differed between cytology and surgical samples, there were 18 responses listing 14 antibodies. A total of 30.6% of laboratories performing IHC offered HER2 testing before publication of the 2007 College of American Pathologists/American Society of Clinical Oncologists guidelines, compared with 33.6% afterward, with increased performance of testing by reference laboratories. Three laboratories validated a nonformalin HER2 platform. The platforms for cytology IHC and positive controls differ for most laboratories, yet conditions are uncommonly adjusted for cytology specimens. Except for the unsuitability of air-dried smears for HER2 testing, the survey did not reveal evidence of systematic problems with any antibody or platform.

  9. Improving Evidence Dissemination and Accessibility through a Mobile-based Resource Platform.

    PubMed

    Zhu, Zheng; Xing, Weijie; Hu, Yan; Zhou, Yingfeng; Gu, Ying

    2018-05-28

    Current mobile information technologies fundamentally influence evidence dissemination from the perspective of both evidence seekers and evidence providers. However, there is no related study which tried using a mobile-based platform to disseminate evidence in China. The main object of this study is to develop a mobile-based evidence resource platform and to evaluate its effects of improving nurses' access to evidence-based practice resources and meeting users' demands. The mobile-based evidence resource platform was developed in 2014. A cross-sectional study was conducted over a period of 2 months between December 2015 and January 2016 to evaluate user experiences of and preferences regarding the platform. Descriptive analysis was adopted to analyze information and its communication effects from December 2014 to March 2017. A total of 472 participants met the inclusion criteria and responded to the survey. High scores were received for the overall rating (4.34 ± 0.67), evidence section (4.30 ± 0.63), learning materials section (4.26 ± 0.65), news section (4.27 ± 0.66), readability (4.38 ± 0.63), design and structure (4.38 ± 0.63), and interactivity (3.58 ± 0.84). As of March 31, 2017, the total number of followers was 28,954. The total number of readings was 584,834. The most current WCI value was 388.72. Our study demonstrated that the mobile-based platform for evidence transfer can promote the accessibility of evidence and meet users' demands. This mobile-based platform is currently available in the WeChat application environment. It will be a wise option for healthcare professionals for the purposes of learning about EBP and disseminating evidence in China.

  10. Favourable rotational alignment outcomes in PSI knee arthroplasty: A Level 1 systematic review and meta-analysis.

    PubMed

    Mannan, A; Smith, T O

    2016-03-01

    Implant malposition in total knee arthroplasty (TKA) often results in unsatisfactory outcomes. Rotational malalignment leads to impaired patellar tracking, stability and joint biomechanics. Patient-specific instrumentation aims to improve three-dimensional implant positioning while reducing overall costs of instrumentation. A PRISMA compliant search of all relevant literature between 2000 and 2014 was performed. The primary outcome of interest was deviation from a neutral femoral and tibial axial alignment of patient-specific instrumentation (PSI) vs conventional instrumentation. Femoral rotation was measured with reference to the transepicondylar axis. Tibial rotation was reported with reference to the anterior tibial tuberosity and a "best fit" with the anterior tibial cortex. Six randomised studies met the inclusion criteria reporting on a total of 444 knees. Computed tomography (CT) based PSI systems were used exclusively in three studies, and two further studies in association with magnetic resonance imaging (MRI). MRI was used exclusively in one study. Mean femoral rotation in the conventional group was: -1.7 to 1.6° (vs -1.7 to 1° in the PSI group). Meta-analysis demonstrated a significant treatment effect favouring PSI with increased accuracy in "three-degree outliers" with femoral rotation: Z=2.07, P=0.04. A single study reported tibial rotational outcomes with no significant difference demonstrated in conventional instrumentation vs PSI. This Level 1 meta-analysis demonstrates favourable femoral rotational alignment outcomes in PSI knee arthroplasty. Only limited data is available for tibial rotational outcomes. Further studies with standardised "gold-standard" measurement criteria are required to clarify tibial rotational outcomes in PSI TKA. 1. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty.

    PubMed

    Maderbacher, Günther; Matussek, Jan; Keshmiri, Armin; Greimel, Felix; Baier, Clemens; Grifka, Joachim; Maderbacher, Hermann

    2018-02-17

    Intramedullary rods are widely used to align the distal femoral cut in total knee arthroplasty. We hypothesised that both coronal (varus/valgus) and sagittal (extension/flexion) cutting plane are affected by rotational changes of intramedullary femoral alignment guides. Distal femoral cuts using intramedullary alignment rods were simulated by means of a computer-aided engineering software in 4°, 6°, 8°, 10°, and 12° of valgus in relation to the femoral anatomical axis and 4° extension, neutral, as well as 4°, 8°, and 12° of flexion in relation to the femoral mechanical axis. This reflects the different angles between anatomical and mechanical axis in coronal and sagittal planes. To assess the influence of rotation of the alignment guide on the effective distal femoral cutting plane, all combinations were simulated with the rod gradually aligned from 40° of external to 40° of internal rotation. Rotational changes of the distal femoral alignment guides affect both the coronal and sagittal cutting planes. When alignment rods are intruded neutrally with regards to sagittal alignment, external rotation causes flexion, while internal rotation causes extension of the sagittal cutting plane. Simultaneously the coronal effect (valgus) decreases resulting in an increased varus of the cutting plane. However, when alignment rods are intruded in extension or flexion partly contradictory effects are observed. Generally the effect increases with the degree of valgus preset, rotation and flexion. As incorrect rotation of intramedullary alignment guides for distal femoral cuts causes significant cutting errors, exact rotational alignment is crucial. Coronal cutting errors in the distal femoral plane might result in overall leg malalignment, asymmetric extension gaps and subsequent sagittal cutting errors.

  12. Reduced glenohumeral rotation, external rotation weakness and scapular dyskinesis are risk factors for shoulder injuries among elite male handball players: a prospective cohort study.

    PubMed

    Clarsen, Benjamin; Bahr, Roald; Andersson, Stig Haugsboe; Munk, Rikke; Myklebust, Grethe

    2014-09-01

    To determine whether rotator cuff strength, glenohumeral joint range of motion and scapular control are associated with shoulder injuries among elite male handball players. A total of 206 players in the Norwegian elite handball league for men were tested prior to the 2011-2012 season. Measures included: (1) glenohumeral internal and external rotation range of motion, (2) isometric internal rotation, external rotation and abduction strength and (3) assessment of scapular dyskinesis. Players were followed prospectively for the entire regular season (30 weeks), with shoulder problems registered bi-weekly using the Oslo Sports Trauma Research Center Overuse Injury Questionnaire. A cumulative severity score was calculated for each player based on their questionnaire responses. This was used as the outcome measure in risk factor analyses. The average prevalence of shoulder problems throughout the season was 28% (95% CI 25% to 31%). The prevalence of substantial shoulder problems, defined as those leading to moderate or severe reductions in handball participation or performance, or to time loss, was 12% (95% CI 11% to 13%). Significant associations were found between obvious scapular dyskinesis (OR 8.41, 95% CI 1.47 to 48.1, p<0.05), total rotational motion (OR 0.77 per 5° change, 95% CI 0.56 to 0.995, p<0.05) and external rotation strength (OR 0.71 per 10 Nm change, 95% CI 0.44 to 0.99, p<0.05) and shoulder injury. Injury prevention programmes should incorporate interventions aimed at improving glenohumeral rotational range of motion, external rotation strength and scapular control. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. The role of the deep medial collateral ligament in controlling rotational stability of the knee.

    PubMed

    Cavaignac, Etienne; Carpentier, Karel; Pailhé, Regis; Luyckx, Thomas; Bellemans, Johan

    2015-10-01

    The tibial insertion of the deep medial collateral ligament (dMCL) is frequently sacrificed when the proximal tibial cut is performed during total knee arthroplasty. The role of the dMCL in controlling the knee's rotational stability is still controversial. The aim of this study was to quantify the rotational laxity induced by an isolated lesion of the dMCL as it occurs during tibial preparation for knee arthroplasty. An isolated resection of the deep MCL was performed in 10 fresh-frozen cadaver knees. Rotational laxity was measured during application of a standard 5.0 N.m rotational torque. Maximal tibial rotation was measured at different knee flexion angles using an image-guided navigation system (Medivision Surgetics system, Praxim, Grenoble, France) before and after dMCL resection. In all cases, internal and external tibial rotation increased after dMCL resection. Total rotational laxity increased significantly for all knee flexion angles, with an average difference of +7.8° (SD 5.7) with the knee in extension, +8.9° (SD 1.9) in 30° flexion, +7° (SD 2.9) in 60° flexion and +5.3° (SD 2.8) in 90° flexion. Sacrificing the tibial insertion of the deep MCL increases rotational laxity of the knee by 5°-9°, depending on the knee flexion angle. Based on our findings, new surgical techniques and implants that preserve the dMCL insertion such as tibial inlay components should be developed. Further clinical evaluations are necessary.

  14. Total Petroleum Systems of the Carpathian - Balkanian Basin Province of Romania and Bulgaria

    USGS Publications Warehouse

    Pawlewicz, Mark

    2007-01-01

    The U.S. Geological Survey defined the Moesian Platform Composite Total Petroleum System and the Dysodile Schist-Tertiary Total Petroleum System, which contain three assessment units, in the Carpathian-Balkanian Basin Province of Romania and Bulgaria. The Moesian Platform Assessment Unit, contained within the Moesian Platform Composite Total Petroleum System, is composed of Mesozoic and Cenozoic rocks within the Moesian platform region of southern Romania and northern Bulgaria and also within the Birlad depression in the northeastern platform area. In Romania, hydrocarbon sources are identified as carbonate rocks and bituminous claystones within the Middle Devonian, Middle Jurassic, Lower Cretaceous, and Neogene stratigraphic sequences. In the Birlad depression, Neogene pelitic strata have the best potential for generating hydrocarbons. In Bulgaria, Middle and Upper Jurassic shales are the most probable hydrocarbon sources. The Romania Flysch Zone Assessment Unit in the Dysodile Schist-Tertiary Total Petroleum System encompasses three structural and paleogeographic subunits within the Pre-Carpathian Mountains region: (1) the Getic depression, a segment of the Carpathian foredeep; (2) the flysch zone of the eastern Carpathian Mountains (also called the Marginal Fold nappe); and (3) the Miocene zone (also called the Sub-Carpathian nappe). Source rocks are interpreted to be Oligocene dysodile schist and black claystone, along with Miocene black claystone and marls. Also part of the Dysodile Schist-Tertiary Total Petroleum System is the Romania Ploiesti Zone Assessment Unit, which includes a zone of diapir folds. This zone lies between the Rimnicu Sarat and Dinibovita valleys and between the folds of the inner Carpathian Mountains and the external flanks of the Carpathian foredeep. The Oligocene Dysodile Schist is considered the main hydrocarbon source rock and Neogene black marls and claystones are likely secondary sources; all are thought to be at their maximum thermal maturation. Undiscovered resources in the Carpathian-Balkanian Basin Province are estimated, at the mean, to be 2,076 billion cubic feet of gas, 1,013 million barrels of oil, and 116 million barrels of natural gas liquids.

  15. Devices and tasks involved in the objective assessment of standing dynamic balancing - A systematic literature review.

    PubMed

    Petró, Bálint; Papachatzopoulou, Alexandra; Kiss, Rita M

    2017-01-01

    Static balancing assessment is often complemented with dynamic balancing tasks. Numerous dynamic balancing assessment methods have been developed in recent decades with their corresponding balancing devices and tasks. The aim of this systematic literature review is to identify and categorize existing objective methods of standing dynamic balancing ability assessment with an emphasis on the balancing devices and tasks being used. Three major scientific literature databases (Science Direct, Web of Science, PLoS ONE) and additional sources were used. Studies had to use a dynamic balancing device and a task described in detail. Evaluation had to be based on objectively measureable parameters. Functional tests without instrumentation evaluated exclusively by a clinician were excluded. A total of 63 articles were included. The data extracted during full-text assessment were: author and date; the balancing device with the balancing task and the measured parameters; the health conditions, size, age and sex of participant groups; and follow-up measurements. A variety of dynamic balancing assessment devices were identified and categorized as 1) Solid ground, 2) Balance board, 3) Rotating platform, 4) Horizontal translational platform, 5) Treadmill, 6) Computerized Dynamic Posturography, and 7) Other devices. The group discrimination ability of the methods was explored and the conclusions of the studies were briefly summarized. Due to the wide scope of this search, it provides an overview of balancing devices and do not represent the state-of-the-art of any single method. The identified dynamic balancing assessment methods are offered as a catalogue of candidate methods to complement static assessments used in studies involving postural control.

  16. Is adapted measured resection superior to gap-balancing in determining femoral component rotation in total knee replacement?

    PubMed

    Luyckx, T; Peeters, T; Vandenneucker, H; Victor, J; Bellemans, J

    2012-09-01

    Obtaining a balanced flexion gap with correct femoral component rotation is one of the prerequisites for a successful outcome after total knee replacement (TKR). Different techniques for achieving this have been described. In this study we prospectively compared gap-balancing versus measured resection in terms of reliability and accuracy for femoral component rotation in 96 primary TKRs performed in 96 patients using the Journey system. In 48 patients (18 men and 30 women) with a mean age of 65 years (45 to 85) a tensor device was used to determine rotation. In the second group of 48 patients (14 men and 34 women) with a mean age of 64 years (41 to 86), an 'adapted' measured resection technique was used, taking into account the native rotational geometry of the femur as measured on a pre-operative CT scan. Both groups systematically reproduced a similar external rotation of the femoral component relative to the surgical transepicondylar axis: 2.4° (SD 2.5) in the gap-balancing group and 1.7° (SD 2.1) in the measured resection group (p = 0.134). Both gap-balancing and adapted measured resection techniques proved equally reliable and accurate in determining femoral component rotation after TKR. There was a tendency towards more external rotation in the gap-balancing group, but this difference was not statistically significant (p = 0.134). The number of outliers for our 'adapted' measured resection technique was much lower than reported in the literature.

  17. Reduction of Tribocorrosion Products When using the Platform-Switching Concept.

    PubMed

    Alrabeah, G O; Knowles, J C; Petridis, H

    2018-03-01

    The reduced marginal bone loss observed when using the platform-switching concept may be the result of reduced amounts of tribocorrosion products released to the peri-implant tissues. Therefore, the purpose of this study was to compare the tribocorrosion product release from various platform-matched and platform-switched implant-abutment couplings under cyclic loading. Forty-eight titanium implants were coupled with pure titanium, gold alloy, cobalt-chrome alloy, and zirconia abutments forming either platform-switched or platform-matched groups ( n = 6). The specimens were subjected to cyclic occlusal forces in a wet acidic environment for 24 h followed by static aqueous immersion for 6 d. The amount of metal ions released was measured using inductively coupled plasma mass spectrometry. Microscopic evaluations were performed pre- and postimmersion under scanning electron microscope (SEM) equipped with energy-dispersive spectroscopy X-ray for corrosion assessment at the interface and wear particle characterization. All platform-switched groups showed less metal ion release compared with their platform-matched counterparts within each abutment material group ( P < 0.001). Implants connected to platform-matched cobalt-chrome abutments demonstrated the highest total mean metal ion release (218 ppb), while the least total mean ion release (11 ppb) was observed in the implants connected to platform-switched titanium abutments ( P ≤ 0.001). Titanium was released from all test groups, with its highest mean release (108 ppb) observed in the implants connected to platform-matched gold abutments ( P < 0.001). SEM images showed surface tribocorrosion features such as pitting and bands of fretting scars. Wear particles were mostly titanium, ranging from submicron to 48 µm in length. The platform-matched groups demonstrated a higher amount of metal ion release and more surface damage. These findings highlight the positive effect of the platform-switching concept in the reduction of tribocorrosion products released from dental implants, which consequently may minimize the adverse tissue reactions that lead to peri-implant bone loss.

  18. The 1980 Large space systems technology. Volume 2: Base technology

    NASA Technical Reports Server (NTRS)

    Kopriver, F., III (Compiler)

    1981-01-01

    Technology pertinent to large antenna systems, technology related to large space platform systems, and base technology applicable to both antenna and platform systems are discussed. Design studies, structural testing results, and theoretical applications are presented with accompanying validation data. A total systems approach including controls, platforms, and antennas is presented as a cohesive, programmatic plan for large space systems.

  19. Suitable Stimuli to Obtain (No) Gender Differences in the Speed of Cognitive Processes Involved in Mental Rotation

    ERIC Educational Resources Information Center

    Jansen-Osmann, Petra; Heil, Martin

    2007-01-01

    Gender differences in speed of perceptual comparison, of picture-plane mental rotation, and in switching costs between trials that do and do not require mental rotation, were investigated as a function of stimulus material with a total sample size of N=360. Alphanumeric characters, PMA symbols, animal drawings, polygons and 3D cube figures were…

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, J; Kim, S; Hristov, D

    Purpose: To assess the potential benefit of trajectory modulated arc therapy (TMAT) for treatments of small benign intracranial tumor, pituitary adenoma. Methods: A TMAT planning platform that incorporates complex source motion trajectory involving synchronized gantry rotation with translational and rotational couch movement was used for the study. The platform couples an interactive trajectory generation tool with a VMAT algorithm that performs multi-resolution, progressive sampling MLC optimization on a user-designed trajectory. A continuous couch rotation of 160° angular span with ±20° mini gantry arcs was used to emulate a non-coplanar horizontal arc-like trajectory. Compared to conventional non-coplanar gantry arcs (60°-100° gantrymore » rotation with couch kicks), TMAT limited the unnecessary low to medium dose spread in the anterior and posterior directions, where primary OARs (e.g., brainstem, optic chiasm, optic nerves, and lens) are in close proximity to the targeted pituitary tumor volume. For 5 standard fractionation pituitary adenoma cases (50.4Gy/28fractions), TMAT and non-coplanar VMAT plans were generated and compared under equivalent objectives/constraints. TMAT delivery was implemented and demonstrated on Varian TrueBeam via XML scripts. Results: Both techniques showed good target coverage while OARs were able to meet the constraints on QUANTEC guidelines. Notably, TMAT decreased the dose deposition in the anterior-to-posterior direction surrounding PTV. TMAT significantly reduced the mean doses on brainstem, optic nerves, eyes and lens by 47.29%±13.17%, 28.51%±8.68%, 80.82%±8.71% and 65.38%±19.99% compared with VMAT, all p≤0.01. Percentage reductions of maximum point dose in eyes and lens were 75.68%±10.30% and 70.72%±18.62% respectively for TMAT versus VMAT, all p≤0.01. A representative isocentric TMAT pituitary plan was delivered via an XML script with 200 control points and 282 MUs. Conclusion: Deliverable TMAT plans were achieved in developer mode in TrueBeam. TMAT was shown to be superior for pituitary adenoma irradiation in terms of OARs sparing.« less

  1. Conversion of Conservation Tillage to Rotational Tillage to Reduce Phosphorus Losses during Snowmelt Runoff in the Canadian Prairies.

    PubMed

    Liu, Kui; Elliott, Jane A; Lobb, David A; Flaten, Don N; Yarotski, Jim

    2014-09-01

    In a preceding study, converting conventional tillage (ConvT) to conservation tillage (ConsT) was reported to decrease nitrogen (N) but to increase phosphorus (P) losses during snowmelt runoff. A field-scale study was conducted from 2004 to 2012 to determine if conversion of ConsT to rotational tillage (RotaT), where conservation tillage was interrupted by a fall tillage pass every other year, could effectively reduce P losses compared with ConsT. The RotaT study was conducted on long-term paired watersheds established in 1993. The ConvT field in the pair has remained under ConvT practice since 1993, whereas tillage was minimized on the ConsT field from 1997 until 2007. In fall 2007, RotaT was introduced to the ConsT field, and heavy-duty cultivator passes were conducted in the late fall of years 2007, 2009, and 2011. Runoff volume and nutrient content were monitored at the edge of the two fields, and soil and crop residue samples were taken in each field. Greater soil Olsen P and more P released from crop residue are likely the reasons for the increased P losses in the ConsT treatment (2004-2007) relative to the ConvT treatment (2004-2007). Analysis of covariance indicated that, compared with ConsT (2004-2007), RotaT (2008-2012) increased the concentrations of dissolved organic carbon (DOC) by 62%, total dissolved N (TDN) by 190%, and total N (TN) by 272% and increased the loads of DOC by 34%, TDN by 34%, and TN by 60%. However, RotaT (2008-2012) decreased soil test P in surface soil, P released from crop residue, and duration of runoff compared with ConsT (2004-2007) and thus decreased the concentrations of total dissolved P (TDP) by 46% and total P (TP) by 38% and decreased the loads of TDP by 56% and TP by 42%. In the Canadian Prairies, where P is a major environmental concern compared with N, RotaT was demonstrated to be an effective practice to reduce P losses compared with ConsT. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  2. [Relationships among job rotation perception and intention, job satisfaction and job performance: a study of Tainan area nurses].

    PubMed

    Pan, Yueh-Chiu; Huang, Pei-Wen; Lee, Jin-Chuan; Chang, Ching-Lu

    2012-04-01

    There have been major changes to the medical care system and heightened standards for quality in the nursing profession in recent decades. Multifunctional capabilities are closely related to individual working attitudes, and work satisfaction directly affects group performance. Hospital administrators increasingly expect to utilize nursing staffs flexibly in terms of working hours and shift rotation assignments. This study addresses the need to provide appropriate educational training to nurses and effectively delegate and utilize human resources in order to help nurses adapt to the rapidly changing medical environment. This study on nursing staff in Tainan area explored the relationships between job rotation, work performance and satisfaction. We used a questionnaire sampling method to survey nurses working in the Tainan area of southern Taiwan. Subjects were volunteers and a total 228 valid questionnaires (99.13%) were returned out of a total 230 sent. Both job satisfaction and performance correlated positively with job rotation perception and intention; Job satisfaction and job performance were positively related; Job satisfaction was found to affect work performance via job rotation perception and intention. This study found the hospital nursing staff rotation plan to be an effective management method that facilitates social evolution to increase positive perceptions of work rotation. Nursing staffs thus become more accepting of new positions that may enhance job satisfaction.

  3. Orthopaedic Surgery Residency: Perspectives of Applicants and Program Directors on Medical Student Away Rotations.

    PubMed

    O'Donnell, Seth W; Drolet, Brian C; Brower, Jonathan P; LaPorte, Dawn; Eberson, Craig P

    2017-01-01

    Senior medical students frequently rotate at orthopaedic residency programs away from their home medical schools. However, to our knowledge, the perspective of program directors (PDs) and applicants on the value, objectives, and costs of these rotations has not been studied. Surveys evaluating the frequency, costs, benefits, and objectives of away rotations were distributed to all orthopaedic residency PDs in the United States and applicants in the 2014-2015 Match cycle. Data analysis was conducted to perform inferential and descriptive statistics; comparisons were made between and among PD and applicant groups using two-tailed means Student t-test and analysis of variance. A total of 74 PD (46.0%) and 524 applicant (49.3%) responses were obtained from a national distribution. Applicants completed an average of 2.4 away rotations, with an average cost of $2,799. When stratified on self-reported likelihood of Matching, there were no substantial differences in the total number of rotations performed. The only marked differences between these groups were the United States Medical Licensing Examination Step 1 score and the number of applications to residency programs. PDs reported that significantly fewer rotations should be allowed, whereas applicants suggested higher limits (2.42 rotations versus 6.24, P < 0.001). PDs and applicants had similar perspectives on the value of away rotations; both groups reported more value in finding a "good fit" and making a good impression at the program and placed less value on the educational impact. The value of orthopaedic away rotations appears more utilitarian than educational for both PDs and applicants. Rotations are performed regardless of perceived likelihood of Matching and are used by students and programs to identify a "good fit." Therefore, given the portion of an academic year that is spent on orthopaedic rotations, findings showing perceived low educational value and marked discrepancies between the expected number of rotations by PDs and applicants indicate that the current structure of away rotations may not be well aligned with the mission of undergraduate medical education. V.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Danguy des Deserts, L.M.J.; Michael, D.; Sedillot, F.G.

    An oscillating platform is described for work at sea, the platform having a weight, comprising a deck, a lattice tower having an upper part and a lower part, the tower further having a total buoyancy center, and a center of gravity, an articulation formed by flexible piles. The articulation has a center; the flexible piles are driven into the sea bed and fixed to the upper part of the tower; the tower comprising floaters in its upper part and a ballast compartment in its lower part, as well as means for resisting shear forces; the product of the total buoyancymore » of the tower by the distance between the buoyancy center of the tower and the center of the articulation are at least equal to 1.25 times the product of the weight of the platform by the distance between the center of gravity of the platform and the center of the articulation.« less

  5. Sorting photons of different rotational Doppler shifts (RDS) by orbital angular momentum of single-photon with spin-orbit-RDS entanglement.

    PubMed

    Chen, Lixiang; She, Weilong

    2008-09-15

    We demonstrate that single photons from a rotating q-plate exhibit an entanglement in three degrees of freedom of spin, orbital angular momentum, and the rotational Doppler shift (RDS) due to the nonconservation of total spin and orbital angular momenta. We find that the rotational Doppler shift deltaomega = Omega((delta)s + deltal) , where s, l and Omega are quantum numbers of spin, orbital angular momentum, and rotating velocity of the q-plate, respectively. Of interest is that the rotational Doppler shift directly reflects the rotational symmetry of q-plates and can be also expressed as deltaomega = (Omega)n , where n = 2(q-1) denotes the fold number of rotational symmetry. Besides, based on this single-photon spin-orbit-RDS entanglement, we propose an experimental scheme to sort photons of different frequency shifts according to individual orbital angular momentum.

  6. Sensorimotor aspects of high-speed artificial gravity: II. The effect of head position on illusory self motion

    NASA Technical Reports Server (NTRS)

    Mast, F. W.; Newby, N. J.; Young, L. R.

    2002-01-01

    The effects of cross-coupled stimuli on the semicircular canals are shown to be influenced by the position of the subject's head with respect to gravity and the axis of rotation, but not by the subject's head position relative to the trunk. Seventeen healthy subjects made head yaw movements out of the horizontal plane while lying on a horizontal platform (MIT short radius centrifuge) rotating at 23 rpm about an earth-vertical axis. The subjects reported the magnitude and duration of the illusory pitch or roll sensations elicited by the cross-coupled rotational stimuli acting on the semicircular canals. The results suggest an influence of head position relative to gravity. The magnitude estimation is higher and the sensation decays more slowly when the head's final position is toward nose-up (gravity in the subject's head x-z-plane) compared to when the head is turned toward the side (gravity in the subject's head y-z-plane). The results are discussed with respect to artificial gravity in space and the possible role of pre-adaptation to cross-coupled angular accelerations on earth.

  7. Total-Internal-Reflection Platforms for Chemical and Biological Sensing Applications

    NASA Astrophysics Data System (ADS)

    Sapsford, Kim E.

    Sensing platforms based on the principle of total internal reflection (TIR) represent a fairly mature yet still expanding and exciting field of research. Sensor development has mainly been driven by the need for rapid, stand-alone, automated devices for application in the fields of clinical diagnosis and screening, food and water safety, environmental monitoring, and chemical and biological warfare agent detection. The technologies highlighted in this chapter are continually evolving, taking advantage of emerging advances in microfabrication, lab-on-a-chip, excitation, and detection techniques. This chapter describes many of the underlying principles of TIR-based sensing platforms and additionally focusses on planar TIR fluorescence (TIRF)-based chemical and biological sensors.

  8. How to install platforms in tidal deltaic areas: The 25-year experience of Total in Kalimantan (Indonesia)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quenelle, A.; Metz, R.; Poirier, D.

    1994-12-31

    Due to the extended work by TOTAL, since 1971, offshore and within the Mahakam delta (East Kalimantan), several installation and platform concepts have been used. The present paper only concerns the installations at Handil and Tambora sites located in the Mahakam delta (in-shore) where water depths are between 2 and 4 meters, water current is 2 knots max. and tide is 2 meters as an average. The experience gained by the company in this kind of job made it possible to recently install in a single piece large and heavy integrated decks (up to 2,600 t) with the optimum usemore » of local skills, non-sophisticated technology and at low costs. The following shows the historical and evolutive experience of TOTAL up to now in platform concepts in this area of the world and gives, by the way, some useful information for future work.« less

  9. [Relationship between occupational stress and mental health in offshore oil platform workers].

    PubMed

    Wu, Hongtao; Xiao, Taiqin; Zou, Jianfang; Shan, Yongle; Li, Zijian

    2014-02-01

    To investigate the relationship between occupational stress and mental health in offshore oil platform workers and to provide a scientific basis for protection of their mental health. A total of 768 workers on offshore oil platform were surveyed with the Occupational Stress Inventory Revised Edition and Symptom Check List-90 (SCL-90). The total score of Occupational Role Questionnaire (ORQ) for the workers (160.27±24.63) was significantly lower than the national norm (166.52±27.01) (P < 0.01); the total score of Personal Strain Questionnaire (PSQ) (101.96±19.8) was significantly higher than the national norm (92.45±17.33) (P < 0.01). The total score of Personal Resource Questionnaire (PRQ) for the workers was not significantly different from the national norm (P > 0.05), but the items of recreation, social support, and rational/cognitive found significant difference (P < 0.05). The total score of SCL-90 was positively correlated with all items of ORQ and PSQ (P < 0.01) and negatively correlated with all items of PRQ (P < 0.01). The multiple stepwise regression analysis showed that current work seniority, education background, drinking, role overload, role insufficiency, role ambiguity, responsibility, physical environment, and rational/cognitive conduct impacted the score of SCL-90 (P < 0.05). The mental health of workers on offshore oil platform is related to occupational stress, and role overload, role ambiguity, physical environment, and rational/cognitive conduct, etc, are closely associated with the workers' mental health.

  10. Within-step modulation of leg muscle activity by afferent feedback in human walking

    PubMed Central

    Klint, Richard af; Nielsen, Jens Bo; Cole, Jonathan; Sinkjaer, Thomas; Grey, Michael J

    2008-01-01

    To maintain smooth and efficient gait the motor system must adjust for changes in the ground on a step-to-step basis. In the present study we investigated the role of sensory feedback as 19 able-bodied human subjects walked over a platform that mimicked an uneven supporting surface. Triceps surae muscle activation was assessed during stance as the platform was set to different inclinations (±3 deg, ±2 deg and 0 deg rotation in a parasagittal plane about the ankle). Normalized triceps surae muscle activity was significantly increased when the platform was inclined (2 deg: 0.153 ± 0.051; 3 deg: 0.156 ± 0.053) and significantly decreased when the platform was declined (−3 deg: 0.133 ± 0.048; −2 deg: 0.132 ± 0.049) compared with level walking (0.141 ± 0.048) for the able-bodied subjects. A similar experiment was performed with a subject who lacked proprioception and touch sensation from the neck down. In contrast with healthy subjects, no muscle activation changes were observed in the deafferented subject. Our results demonstrate that the ability to compensate for small irregularities in the ground surface relies on automatic within-step sensory feedback regulation rather than conscious predictive control. PMID:18669536

  11. Multilevel microvibration test for performance predictions of a space optical load platform

    NASA Astrophysics Data System (ADS)

    Li, Shiqi; Zhang, Heng; Liu, Shiping; Wang, Yue

    2018-05-01

    This paper presents a framework for the multilevel microvibration analysis and test of a space optical load platform. The test framework is conducted on three levels, including instrument, subsystem, and system level. Disturbance source experimental investigations are performed to evaluate the vibration amplitude and study vibration mechanism. Transfer characteristics of space camera are validated by a subsystem test, which allows the calculation of transfer functions from various disturbance sources to optical performance outputs. In order to identify the influence of the source on the spacecraft performance, a system level microvibration measurement test has been performed on the ground. From the time domain analysis and spectrum analysis of multilevel microvibration tests, we concluded that the disturbance source has a significant effect on its installation position. After transmitted through mechanical links, the residual vibration reduces to a background noise level. In addition, the angular microvibration of the platform jitter is mainly concentrated in the rotation of y-axes. This work is applied to a real practical application involving the high resolution satellite camera system.

  12. Investigation of Slosh Dynamics on Flight and Ground Platforms

    NASA Astrophysics Data System (ADS)

    Vergalla, Michael; Zhou, Ran

    The slosh dynamics in cryogenic fuel tanks under microgravity is a problem that severely affects the reliability of spacecraft launching. To investigate slosh dynamics and their effects on space vehicle dynamics three levels of testing are presently in progress. Platforms include a 3-DOF ground testing table, parabolic flights, sounding rockets and finally the International Space Station. Ground tests provide an economically viable platform for investigating rotational, translational, and coupled feed-back modes due to repeatable CNC motions. The parabolic flight campaign has conducted four successful flights aboard multiple aircraft using static and tethered slosh packages. Using the PANTHER II student designed rocket, a slosh package was launched as a payload. Finally with collaboration between Florida Institute of Technology and Massachusetts Institute of Technology SPHERES project, two test sessions investigating feedback using partially and fully filled propellant tanks have been completed aboard the In-ternational Space Station. Motion data from all tests will be input to in house Dynamic Mesh Model to further establish confidence in the versatility and accuracy of the method. The results show that it is necessary to construct additional hardware for slosh studies.

  13. Fly's Eye camera system: optical imaging using a hexapod platform

    NASA Astrophysics Data System (ADS)

    Jaskó, Attila; Pál, András.; Vida, Krisztián.; Mészáros, László; Csépány, Gergely; Mező, György

    2014-07-01

    The Fly's Eye Project is a high resolution, high coverage time-domain survey in multiple optical passbands: our goal is to cover the entire visible sky above the 30° horizontal altitude with a cadence of ~3 min. Imaging is going to be performed by 19 wide-field cameras mounted on a hexapod platform resembling a fly's eye. Using a hexapod developed and built by our team allows us to create a highly fault-tolerant instrument that uses the sky as a reference to define its own tracking motion. The virtual axis of the platform is automatically aligned with the Earth's rotational axis; therefore the same mechanics can be used independently from the geographical location of the device. Its enclosure makes it capable of autonomous observing and withstanding harsh environmental conditions. We briefly introduce the electrical, mechanical and optical design concepts of the instrument and summarize our early results, focusing on sidereal tracking. Due to the hexapod design and hence the construction is independent from the actual location, it is considerably easier to build, install and operate a network of such devices around the world.

  14. Effects of whole body vibration training on postural control in older individuals: a 1 year randomized controlled trial.

    PubMed

    Bogaerts, An; Verschueren, Sabine; Delecluse, Christophe; Claessens, Albrecht L; Boonen, Steven

    2007-07-01

    This randomized controlled trial investigated the effects of a 12 month whole body vibration training program on postural control in healthy older adults. Two hundred and twenty people were randomly assigned to a whole body vibration group (n=94), a fitness group (n=60) or a control group (n=66). The whole body vibration and fitness groups trained three times a week for 1 year. The vibration group performed exercises on a vibration platform and the fitness group performed cardiovascular, strength, balance and stretching exercises. Balance was measured using dynamic computerized posturography at baseline and after 6 and 12 months. Whole body vibration training was associated with reduced falls frequency on a moving platform when vision was disturbed and improvements in the response to toes down rotations at the ankle induced by the moving platform. The fitness group showed reduced falls frequency on the moving surface when vision was disturbed. Thus, whole body vibration training may improve some aspects of postural control in community dwelling older individuals.

  15. Clinical Track Program Expansion Increases Rotation Capacity for Experiential Program.

    PubMed

    Tofade, Toyin S; Brueckl, Mark; Ross, Patricia A

    2017-10-01

    Objective. To evaluate the rotation capacity at the University of Maryland School of Pharmacy and see if the implementation of clinical track programs across the state correlates to an increase in rotation capacity for the school. Methods. The following information was collected: number of preceptors over the years in the school's experiential learning program, number of clinical track programs from 2012 to 2015, rotation type, availability submissions per rotation type per year, and availability submissions per hospital participant in the clinical track program per year. The rotation capacity and rotation types from 2012 to 2015 academic years were assessed and compared to see if there was any impact on the clinical track programs implemented. Results. There was no statistically significant difference in the frequency distribution of rotation types among all sites from 2012 through 2015 academic years. However, there was a statistically significant difference in the total number/capacity of rotations from 2012 to 2015 academic years. There were also statistically significant differences in the rotation capacity in all sites except for three sites. Conclusion. Adding clinical track programs can help increase the capacity of a school's clinical rotations.

  16. Design and Analysis of a Seismically Stable Platform. An Evaluation

    DTIC Science & Technology

    1980-08-01

    Electronics Center, Cambridge, MA: "Design of a Precision Tilt and Rotational Vibration Isolation System for Inertial Sensor Testing", AIAA Paper 68-894...Again, the measurements are made random walk. There is some evidence that this with tiltmeters and azimuth information is not process is actually an...made with tiltmeters . However, kept in mind in interpreting the data. First, it is it has not been observed with gyros or with other valid only for

  17. Degradable Magnetic Composites for Minimally Invasive Interventions: Device Fabrication, Targeted Drug Delivery, and Cytotoxicity Tests.

    PubMed

    Peters, Christian; Hoop, Marcus; Pané, Salvador; Nelson, Bradley J; Hierold, Christofer

    2016-01-20

    Superparamagnetic nanoparticles and a functional, degradable polymer matrix based on poly(ethylene glycol) are combined to enable fully degradable magnetic microdevices for minimally invasive biomedical applications. A bioinspired helical microrobot platform mimicking Escherichia coli bacteria is fabricated and actuated using weak rotating magnetic fields. Locomotion based on corkscrew propulsion, targeted drug delivery, and low-degradation-product cytotoxicity are demonstrated. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Fan; Wang, Yuanqing, E-mail: yqwang@nju.edu.cn; Li, Fenfang

    The avalanche-photodiode-array (APD-array) laser detection and ranging (LADAR) system has been continually developed owing to its superiority of nonscanning, large field of view, high sensitivity, and high precision. However, how to achieve higher-efficient detection and better integration of the LADAR system for real-time three-dimensional (3D) imaging continues to be a problem. In this study, a novel LADAR system using four linear mode APDs (LmAPDs) is developed for high-efficient detection by adopting a modulation and multiplexing technique. Furthermore, an automatic control system for the array LADAR system is proposed and designed by applying the virtual instrumentation technique. The control system aimsmore » to achieve four functions: synchronization of laser emission and rotating platform, multi-channel synchronous data acquisition, real-time Ethernet upper monitoring, and real-time signal processing and 3D visualization. The structure and principle of the complete system are described in the paper. The experimental results demonstrate that the LADAR system is capable of achieving real-time 3D imaging on an omnidirectional rotating platform under the control of the virtual instrumentation system. The automatic imaging LADAR system utilized only 4 LmAPDs to achieve 256-pixel-per-frame detection with by employing 64-bit demodulator. Moreover, the lateral resolution is ∼15 cm and range accuracy is ∼4 cm root-mean-square error at a distance of ∼40 m.« less

  19. Design and Development of Micro-Power Generating Device for Biomedical Applications of Lab-on-a-Disc.

    PubMed

    Joseph, Karunan; Ibrahim, Fatimah; Cho, Jongman; Thio, Tzer Hwai Gilbert; Al-Faqheri, Wisam; Madou, Marc

    2015-01-01

    The development of micro-power generators for centrifugal microfluidic discs enhances the platform as a green point-of-care diagnostic system and eliminates the need for attaching external peripherals to the disc. In this work, we present micro-power generators that harvest energy from the disc's rotational movement to power biomedical applications on the disc. To implement these ideas, we developed two types of micro-power generators using piezoelectric films and an electromagnetic induction system. The piezoelectric-based generator takes advantage of the film's vibration during the disc's rotational motion, whereas the electromagnetic induction-based generator operates on the principle of current generation in stacks of coil exposed to varying magnetic flux. We have successfully demonstrated that at the spinning speed of 800 revolutions per minute (RPM) the piezoelectric film-based generator is able to produce up to 24 microwatts using 6 sets of films and the magnetic induction-based generator is capable of producing up to 125 milliwatts using 6 stacks of coil. As a proof of concept, a custom made localized heating system was constructed to test the capability of the magnetic induction-based generator. The heating system was able to achieve a temperature of 58.62 °C at 2200 RPM. This development of lab-on-a-disc micro power generators preserves the portability standards and enhances the future biomedical applications of centrifugal microfluidic platforms.

  20. Effects of Grazing Management and Buffer Strips on Metal Runoff from Pastures Fertilized with Poultry Litter.

    PubMed

    Pilon, C; Moore, P A; Pote, D H; Martin, J W; DeLaune, P B

    2017-03-01

    Metal runoff from fields fertilized with poultry litter may pose a threat to aquatic systems. Buffer strips located adjacent to fields may reduce nutrients and solids in runoff. However, scant information exists on the long-term effects of buffer strips combined with grazing management on metal runoff from pastures. The objective of this study was to assess the 12-yr impact of grazing management and buffer strips on metal runoff from pastures receiving poultry litter. The research was conducted using 15 watersheds (25 m wide and 57 m long) with five treatments: hayed (H), continuously grazed (CG), rotationally grazed (R), rotationally grazed with a buffer strip (RB), and rotationally grazed with a fenced riparian buffer strip (RBR). Poultry litter was applied annually in spring at 5.6 Mg ha. Runoff samples were collected after every rainfall event. Aluminum (Al) and iron (Fe) concentrations were strongly and positively correlated with total suspended solids, indicating soil erosion was the primary source. Soluble Al and Fe were not related to total Al and Fe. However, there was a strong positive correlation between soluble and total copper (Cu) concentrations. The majority of total Cu and zinc was in water-soluble form. The CG treatment had the highest metal concentrations and loads of all treatments. The RBR and H treatments resulted in lower concentrations of total Al, Cu, Fe, potassium, manganese, and total organic carbon in the runoff. Rotational grazing with a fenced riparian buffer and converting pastures to hayfields appear to be effective management systems for decreasing concentrations and loads of metals in surface runoff from pastures fertilized with poultry litter. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.

  1. Serum metal ion levels after rotating-hinge knee arthroplasty: comparison between a standard device and a megaprosthesis.

    PubMed

    Friesenbichler, Joerg; Maurer-Ertl, Werner; Sadoghi, Patrick; Lovse, Thomas; Windhager, Reinhard; Leithner, Andreas

    2012-03-01

    The effects of systemic metal ion exposure in patients with implants made of common prosthetic alloys continue to be a matter of concern. The aim of the study was to determine the measurement values of cobalt (Co), chromium (Cr) and molybdenum (Mo) in serum following rotating-hinge knee arthroplasty. Blood was taken from 25 patients [mean follow-up 35 (range nine to 67) months] treated with megaprostheses (n=17) or standard rotating-hinge devices (n=8) and analysed using electrothermal graphite furnace atomic absorption spectrometry (ET-ASS). Determining the concentrations of metal ions following rotating-hinge knee arthroplasty revealed increments for Co and Cr but not Mo. Metal ion release was significantly higher in patients with megaprostheses compared to a standard rotating-hinge knee device (Co p=0,024; Cr p=0.025). The authors believe there might be an additional metal ion release from the surface of the prosthesis and not only from the articulating surfaces because, in cases of rotating-hinge knee prosthesis, there is a metal-on-polyethylene articulation and not a direct metal-on-metal junction. Nevertheless, long-term studies are required to determine adverse effects of Co, Cr and Mo following total hip replacement and total knee arthroplasty.

  2. Effect of shoe insert construction on foot and leg movement.

    PubMed

    Nigg, B M; Khan, A; Fisher, V; Stefanyshyn, D

    1998-04-01

    The purpose of this study was to quantify changes in foot eversion and tibial rotation during running resulting from systematic changes of material composition of five shoe inserts of the same shape. Tests were performed with 12 subjects. The inserts had a bilayer design using two different materials at the top and bottom of the insert. The functional kinematic variables examined in this study were the foot-leg in-eversion angle, beta, and the leg-foot tibial rotation, rho. Additionally, the subject characteristics of arch height, relative arch deformation, and active range of motion were quantified. The statistical analysis used was a two way repeated measures MANOVA (within trials and inserts). The average group changes resulting from the studied inserts in total shoe eversion, total foot eversion, and total internal tibial rotation were typically smaller than 1 degree when compared with the no-insert condition and were statistically not significant. The measured ranges of total foot eversion for all subjects were smallest for the softest and about twice as large for the hardest insert construction. Thus, the soft insert construction was more restrictive, forcing all feet into a similar movement pattern, whereas the harder combinations allowed for more individual variation of foot and leg movement and did not force the foot into a preset movement pattern. The individual results showed substantial differences between subjects and a trend: Subjects who generally showed a reduction of tibial rotation with all tested inserts typically had a flexible foot. However, subjects who generally showed an increase of tibial rotation typically had a stiff foot. The results of this study suggest that subject specific factors such as static, dynamic, and neuro-physiological characteristics of foot and leg are important to match specific feet and shoe inserts optimally.

  3. Posterior tibial slope and femoral sizing affect posterior cruciate ligament tension in posterior cruciate-retaining total knee arthroplasty.

    PubMed

    Kuriyama, Shinichi; Ishikawa, Masahiro; Nakamura, Shinichiro; Furu, Moritoshi; Ito, Hiromu; Matsuda, Shuichi

    2015-08-01

    During cruciate-retaining total knee arthroplasty, surgeons sometimes encounter increased tension of the posterior cruciate ligament. This study investigated the effects of femoral size, posterior tibial slope, and rotational alignment of the femoral and tibial components on forces at the posterior cruciate ligament in cruciate-retaining total knee arthroplasty using a musculoskeletal computer simulation. Forces at the posterior cruciate ligament were assessed with the standard femoral component, as well as with 2-mm upsizing and 2-mm downsizing in the anterior-posterior dimension. These forces were also determined with posterior tibial slope angles of 5°, 7°, and 9°, and lastly, were measured in 5° increments when the femoral (tibial) components were positioned from 5° (15°) of internal rotation to 5° (15°) of external rotation. Forces at the posterior cruciate ligament increased by up to 718N with the standard procedure during squatting. The 2-mm downsizing of the femoral component decreased the force at the posterior cruciate ligament by up to 47%. The 2° increment in posterior tibial slope decreased the force at the posterior cruciate ligament by up to 41%. In addition, posterior cruciate ligament tension increased by 11% during internal rotation of the femoral component, and increased by 18% during external rotation of the tibial component. These findings suggest that accurate sizing and bone preparation are very important to maintain posterior cruciate ligament forces in cruciate-retaining total knee arthroplasty. Care should also be taken regarding malrotation of the femoral and tibial components because this increases posterior cruciate ligament tension. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. The correlation between the total magnetic flux and the total jet power

    NASA Astrophysics Data System (ADS)

    Nokhrina, Elena E.

    2017-12-01

    Magnetic field threading a black hole ergosphere is believed to play the key role in both driving the powerful relativistic jets observed in active galactic nuclei and extracting the rotational energy from a black hole via Blandford-Znajek process. The magnitude of magnetic field and the magnetic flux in the vicinity of a central black hole is predicted by theoretical models. On the other hand, the magnetic field in a jet can be estimated through measurements of either the core shift effect or the brightness temperature. In both cases the obtained magnetic field is in the radiating domain, so its direct application to the calculation of the magnetic flux needs some theoretical assumptions. In this paper we address the issue of estimating the magnetic flux contained in a jet using the measurements of a core shift effect and of a brightness temperature for the jets, directed almost at the observer. The accurate account for the jet transversal structure allow us to express the magnetic flux through the observed values and an unknown rotation rate of magnetic surfaces. If we assume the sources are in a magnetically arrested disk state, the lower limit for the rotation rate can be obtained. On the other hand, the flux estimate may be tested against the total jet power predicted by the electromagnetic energy extraction model. The resultant expression for power depends logarithmically weakly on an unknown rotation rate. We show that the total jet power estimated through the magnetic flux is in good agreement with the observed power. We also obtain the extremely slow rotation rates, which may be an indication that the majority of the sources considered are not in the magnetically arrested disk state.

  5. A Low Noise, Microprocessor-Controlled, Internally Digitizing Rotating-Vane Electric Field Mill for Airborne Platforms

    NASA Technical Reports Server (NTRS)

    Bateman, M. G.; Stewart, M. F.; Blakeslee, R. J.; Podgorny, s. J.; Christian, H. J.; Mach, D. M.; Bailey, J. C.; Daskar, D.

    2006-01-01

    This paper reports on a new generation of aircraft-based rotating-vane style electric field mills designed and built at NASA's Marshall Spaceflight Center. The mills have individual microprocessors that digitize the electric field signal at the mill and respond to commands from the data system computer. The mills are very sensitive (1 V/m per bit), have a wide dynamic range (115 dB), and are very low noise (+/-1 LSB). Mounted on an aircraft, these mills can measure fields from +/-1 V/m to +/-500 kV/m. Once-per-second commanding from the data collection computer to each mill allows for precise timing and synchronization. The mills can also be commanded to execute a self-calibration in flight, which is done periodically to monitor the status and health of each mill.

  6. French comparison exercise with the rotating neutron spectrometer, 'ROSPEC'.

    PubMed

    Crovisier, P; Asselineau, B; Pelcot, G; Van-Ryckeghem, L; Cadiou, A; Truffert, H; Groetz, J E; Benmosbah, M

    2005-01-01

    The French laboratories in charge of 'neutron' dosimetry using the spectrometer 'ROSPEC', formed a working group in 2001. The participants began to study the behaviour of the instrument with a comparison exercise in broad energy neutron fields recommended by the International Organisation for Standardisation (ISO) and available at the LMDN in Cadarache. The complete version of the ROSPEC is made up of six spherical proportional counters fixed to a rotating platform. These counters cover different energy ranges which overlap each other to provide a link between the detectors, within the energy range from thermal neutrons to 4.5 MeV. The irradiation configurations chosen were ISO standard sources (252Cf, (252Cf+D2O)(/Cd), 241Am-Be) and the SIGMA facility. The results show that the 'thermal and epithermal' neutron fluence was widely overestimated by the spectrometer in all configurations.

  7. Payload canister for Discovery is lifted in place for transfer

    NASA Technical Reports Server (NTRS)

    1998-01-01

    At left, the payload canister for Space Shuttle Discovery is lifted from its canister movement vehicle to the top of the Rotating Service Structure on Launch Pad 39-B. Discovery (right), sitting atop the Mobile Launch Platform and next to the Fixed Service Structure (FSS), is scheduled for launch on Oct. 29, 1998, for the STS-95 mission. That mission includes the International Extreme Ultraviolet Hitchhiker (IEH-3), the Hubble Space Telescope Orbital Systems Test Platform, the Spartan solar- observing deployable spacecraft, and the SPACEHAB single module with experiments on space flight and the aging process. At the top of the FSS can be seen the 80-foot lightning mast . The 4- foot-high lightning rod on top helps prevent lightning current from passing directly through the Space Shuttle and the structures on the pad.

  8. Turbine blade platform seal

    DOEpatents

    Zagar, Thomas W.; Schiavo, Anthony L.

    2001-01-01

    A rotating blade group 90 for a turbo-machine having an improved device for sealing the gap 110 between the edges 112,114 of adjacent blade platforms 96,104. The gap 110 between adjacent blades 92,100 is sealed by a seal pin 20 its central portion 110 and by a seal plate 58,60 at each of the front 54 and rear 56 portions. The seal plates 58,60 are inserted into corresponding grooves 62,64 formed in the adjacent edges 112,114 of adjoining blades 92,100 and held in place by end plates 40,42. The end of the seal plates 58,60 may be chamfered 78,80 to improve the seal against the end plate 40,42. The seal pin 20 provides the required damping between the blades 92,100 and the seal plates 58,60 provide improved sealing effectiveness.

  9. Practical UAV Optical Sensor Bench with Minimal Adjustability

    NASA Technical Reports Server (NTRS)

    Pilgrim, Jeffrey; Gonzales, Paula

    2013-01-01

    A multiple-pass optical platform eliminates essentially all optical alignment degrees of freedom, save one. A four-pass absorption spectrometer architecture is made rigid by firmly mounting dielectric-coated mirror prisms with no alignment capability to the platform. The laser diode beam is collimated by a small, custom-developed lens, which has only a rotational degree of freedom along the standard optical "z" axis. This degree is itself eliminated by adhesive after laser collimation. Only one degree of freedom is preserved by allowing the laser diode chip and mount subassembly to move relative to the collimating lens by using over-sized mounting holes. This allows full 360 deg motion of a few millimeters relative to the lens, which, due to the high numerical aperture of the lens, provides wide directional steering of the collimated laser beam.

  10. Going "open" with mesoscopy: a new dimension on multi-view imaging.

    PubMed

    Gualda, Emilio; Moreno, Nuno; Tomancak, Pavel; Martins, Gabriel G

    2014-03-01

    OpenSPIM and OpenSpinMicroscopy emerged as open access platforms for Light Sheet and Optical Projection Imaging, often called as optical mesoscopy techniques. Both projects can be easily reproduced using comprehensive online instructions that should foster the implementation and further development of optical imaging techniques with sample rotation control. This additional dimension in an open system offers the possibility to make multi-view microscopy easily modified and will complement the emerging commercial solutions. Furthermore, it is deeply based on other open platforms such as MicroManager and Arduino, enabling development of tailored setups for very specific biological questions. In our perspective, the open access principle of OpenSPIM and OpenSpinMicroscopy is a game-changer, helping the concepts of light sheet and optical projection tomography (OPT) to enter the mainstream of biological imaging.

  11. Whole-body vibration therapy in children with severe motor disabilities.

    PubMed

    Kilebrant, Sophie; Braathen, Gunnar; Emilsson, Roger; Glansén, Ulla; Söderpalm, Ann-Charlott; Zetterlund, Bo; Westerberg, Barbro; Magnusson, Per; Swolin-Eide, Diana

    2015-03-01

    To study the effect of whole-body vibration therapy on bone mass, bone turnover and body composition in severely disabled children. Nineteen non-ambulatory children aged 5.1-16.3 years (6 males, 13 females) with severe motor disabilities participated in an intervention programme with standing exercise on a self-controlled dynamic platform, which included whole-body vibration therapy (vibration, jump and rotation movements). Whole-body vibration therapy was performed at 40-42 Hz, with an oscillation amplitude of 0.2 mm, 5-15 min/treatment, twice/week for 6 months. Bone mass parameters and bone markers were measured at the study start, and after 6 and 12 months. Whole-body vibration therapy was appreciated by the children. Total-body bone mineral density increased during the study period (p < 0.05). Z-scores for total-body bone mineral density ranged from -5.10 to -0.60 at study start and remained unchanged throughout. Approximately 50% of the subjects had increased levels of carboxy-terminal telopeptides of type I collagen and decreased levels of osteocalcin at the start. Body mass index did not change during the intervention period, but had increased by the 12-month follow-up (p < 0.05). Whole-body vibration therapy appeared to be well tolerated by children with severe motor disabilities. Total-body bone mineral density increased after 6 months of whole-body vibration therapy. Higher carboxy-terminal telopeptides of type I collagen and lower osteocalcin values indicated that severely disabled children have a reduced capacity for bone acquisition.

  12. Platform C North Arrival

    NASA Image and Video Library

    2016-08-30

    A section of the second half of the C-level platforms, C North, for NASA’s Space Launch System (SLS) rocket, arrives at the agency’s Kennedy Space Center in Florida. The platform was offloaded from a heavy lift transport truck and secured in a staging area in the west parking lot of the Vehicle Assembly Building (VAB). The Ground Systems Development and Operations Program is overseeing upgrades and modifications to VAB High Bay 3 to support processing of the SLS and Orion spacecraft. A total of 10 levels of new platforms, 20 platform halves altogether, will surround the SLS rocket and Orion spacecraft and provide access for testing and processing.

  13. Spatial variability of soil total and DTPA-extractable cadmium caused by long-term application of phosphate fertilizers, crop rotation, and soil characteristics.

    PubMed

    Jafarnejadi, A R; Sayyad, Gh; Homaee, M; Davamei, A H

    2013-05-01

    Increasing cadmium (Cd) accumulation in agricultural soils is undesirable due to its hazardous influences on human health. Thus, having more information on spatial variability of Cd and factors effective to increase its content on the cultivated soils is very important. Phosphate fertilizers are main contamination source of cadmium (Cd) in cultivated soils. Also, crop rotation is a critical management practice which can alter soil Cd content. This study was conducted to evaluate the effects of long-term consumption of the phosphate fertilizers, crop rotations, and soil characteristics on spatial variability of two soil Cd species (i.e., total and diethylene triamine pentaacetic acid (DTPA) extractable) in agricultural soils. The study was conducted in wheat farms of Khuzestan Province, Iran. Long-term (27-year period (1980 to 2006)) data including the rate and the type of phosphate fertilizers application, the respective area, and the rotation type of different regions were used. Afterwards, soil Cd content (total or DTPA extractable) and its spatial variability in study area (400,000 ha) were determined by sampling from soils of 255 fields. The results showed that the consumption rate of di-ammonium phosphate fertilizer have been varied enormously in the period study. The application rate of phosphorus fertilizers was very high in some subregions with have extensive agricultural activities (more than 95 kg/ha). The average and maximum contents of total Cd in the study region were obtained as 1.47 and 2.19 mg/kg and DTPA-extractable Cd as 0.084 and 0.35 mg/kg, respectively. The spatial variability of Cd indicated that total and DTPA-extractable Cd contents were over 0.8 and 0.1 mg/kg in 95 and 25 % of samples, respectively. The spherical model enjoys the best fitting and lowest error rate to appraise the Cd content. Comparing the phosphate fertilizer consumption rate with spatial variability of the soil cadmium (both total and DTPA extractable) revealed the high correlation between the consumption rate of P fertilizers and soil Cd content. Rotation type was likely the main effective factor on variations of the soil DTPA-extractable Cd contents in some parts (eastern part of study region) and could explain some Cd variation. Total Cd concentrations had significant correlation with the total neutralizing value (p < 0.01), available P (p < 0.01), cation exchange capacity (p < 0.05), and organic carbon (p < 0.05) variables. The DTPA-extractable Cd had significant correlation with OC (p < 0.01), pH, and clay content (p < 0.05). Therefore, consumption rate of the phosphate fertilizers and crop rotation are important factors on solubility and hence spatial variability of Cd content in agricultural soils.

  14. T sub 1-echo sequence: Protecting the State of a Qubit in the Presence of Coherent Interaction

    DTIC Science & Technology

    2012-09-25

    memory is at energy m, and they are coupled with a coupling strength v⊥. We write the coupling in the rotating - wave approximation , assuming q,m...important for the time evolution. In the validity range of the rotating - wave approximation , the above Hamiltonian preserves the total number of...excited state) in total is involved in the dynamics, the underlying Jaynes - Cummings Hamiltonian will lead to the same results as the ones presented here

  15. Active Control of a Pneumatic Isolation System,

    DTIC Science & Technology

    A pneumatically isolated test platform has been modified to provide active control to the local gravity vector. A combination of sensors , including... tiltmeters , angular accelerometers, seismometers, and a gyrocompass measure total platform motion between 0 and 100 Hz. Electrical-to-pressure

  16. Does lateral versus medial exposure influence total knee tibial component final external rotation? A CT based study.

    PubMed

    Passeron, D; Gaudot, F; Boisrenoult, P; Fallet, L; Beaufils, P

    2009-10-01

    A previous study demonstrated that performing a total knee arthroplasty through a lateral approach including anterior tibial tuberosity (ATT) osteotomy (refixed in its original position) presented numerous advantages: correcting the preoperative patella lateral tilt and improving postoperative patella tracking. We hypothesized that these improvements in patella centering were, at least in part, due to an increased external rotation of the tibial component. Postoperative scannographic studies were, therefore, undertaken to measure tibial component rotation and analyze the results according the medial and lateral exposure used. Rotational positioning of the tibial component is influenced by the lateral or medial approach selected at surgery. Forty-five CAT scans, performed according to the protocol criteria of the French Hip and Knee Society (SFHG), were studied 3 months postoperatively: 15 knees operated through the lateral approach and 30 knees operated through a standard medial approach. The total knee utilized in all these cases was a posteriorly stabilized, fixed-bearing, design. We measured first the angle formed between the perpendicular to the transverse axis of the tibial component and the axis joining the ATT to the center of the knee; second we also measured the coronal distance between the center of the component and the anterior tibial tuberosity (ATT). In the group using the medial approach, the lateral position of the ATT was 7 + or - 3mm with a rotation angle of 18 degrees . In the group using the lateral approach these measurements were respectively 1 + or - 4mm and 2 degrees (p<0.0001). External rotation of the tibial component is substantially increased by the lateral approach compared to the medial approach. Better exposure of the lateral tibial plateau is probably responsible of this difference. This increased external rotation improves postoperative patella tracking. Prospective; comparative; non-randomized study; level 3. 2009 Elsevier Masson SAS. All rights reserved.

  17. Comparison of the effect of the rotation palatoplasty and V-Y pushback palatoplasty techniques on palate elongation with magnetic resonance imaging.

    PubMed

    Isik, D; Bora, A; Yuce, S; Davran, R; Kocak, O F; Canbaz, Y; Avcu, S; Atik, B

    2015-06-01

    Most surgical techniques used in cleft palate repair require the extension of the palate to the pharynx. However, no adequate information exists regarding the extent to which this elongation obtained during operation continues in late postoperative period. In this study, we compared and measured palate elongation in patients with a cleft palate who underwent a V-Y pushback or rotation palatoplasty, by means of magnetic resonance images obtained before and 1 year after surgery. The hard palate, soft palate, and total palate lengths were measured for all of the patients, and the velopharyngeal opening area width was calculated. In patients who underwent the V-Y pushback technique (n=13), the total palate and soft palate lengths were shortened by an average of 0.10 and 0.14cm after surgery, respectively. However, the hard palate length was elongated by an average of 0.13cm. In the rotation palatoplasty group (n=13), the total palate, hard palate, and soft palate lengths were elongated by 0.57, 0.10, and 0.49cm, respectively. The velopharyngeal opening was narrowed by 0.06cm(2) using the V-Y pushback technique and by 0.29cm(2) using the rotational palatoplasty. This study demonstrated that the palate does not elongate during the V-Y pushback technique, as expected. However, rotational palatoplasty elongates the soft palate. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  18. Aksu-Dinar Fault System: Its bearing on the evolution of the Isparta Angle (SW Turkey)

    NASA Astrophysics Data System (ADS)

    Kaymakci, Nuretdin; Özacar, Arda; Langereis, Cornelis G.; Özkaptan, Murat; Gülyüz, Erhan; van Hinsbergen, Douwe J. J.; Uzel, Bora; McPhee, Peter; Sözbilir, Hasan

    2017-04-01

    The Isparta Angle is a triangular structure in SW Turkey with NE-SW trending western and NW-SE trending eastern flanks. Aksu Fault is located within the core of this structure and have been taken-up large E-W shortening and sinistral translation since the Late Miocene. It is an inherited structure which emplaced Antalya nappes over the Beydaǧları Platform during the late Eocene to Late Miocene and was reactivated by the Pliocene as a high angle reverse fault to accommodate the counter-clockwise rotation of Beydaǧları and SW Anatolia. On the other hand, the Dinar Fault is a normal fault with slight sinistral component has been active since Pliocene. These two structures are collinear and delimit areas with clockwise and counter-clockwise rotations. The areas to the north and east of these structures rotated clockwise while southern and western areas are rotated counter-clockwise. We claim that the Dinar-Aksu Fault System facilitate rotational deformation in the region as a scissor like mechanism about a pivot point north of Burdur. This mechanism resulted in the normal motion along the Dinar and reverse motion along the Aksu faults with combined sinistral translation component on both structures. We claim that the driving force for the motion of these faults and counter-clockwise rotation of the SW Anatolia seems to be slab-pull forces exerted by the east dipping Antalya Slab, a relic of Tethys oceanic lithosphere. The research for this paper is supported by TUBITAK - Grant Number 111Y239. Key words: Dinar Fault, Aksu Fault, Isparta Angle, SW Turkey, Burdur Pivot, Normal Fault, Reverse Fault

  19. The effect of technique change on knee loads during sidestep cutting.

    PubMed

    Dempsey, Alasdair R; Lloyd, David G; Elliott, Bruce C; Steele, Julie R; Munro, Bridget J; Russo, Kylie A

    2007-10-01

    To identify the effect of modifying sidestep cutting technique on knee loads and predict what impact such change would have on the risk of noncontact anterior cruciate ligament injury. A force platform and motion-analysis system were used to record ground-reaction forces and track the trajectories of markers on 15 healthy males performing sidestep cutting tasks using their normal technique and nine different imposed techniques. A kinematic and inverse dynamic model was used to calculate the three-dimensional knee postures and moments. The imposed techniques of foot wide and torso leaning in the opposite direction to the cut resulted in increased peak valgus moments experienced in weight acceptance. Higher peak internal rotation moments were found for the foot wide and torso rotation in the opposite direction to the cut techniques. The foot rotated in technique resulted in lower mean flexion/extension moments, whereas the foot wide condition resulted in higher mean flexion/extension moments. The flexed knee, torso rotated in the opposite direction to the cut and torso leaning in the same direction as the cut techniques had significantly more knee flexion at heel strike. Sidestep cutting technique had a significant effect on loads experienced at the knee. The techniques that produced higher valgus and internal rotation moments at the knee, such as foot wide, torso leaning in the opposite direction to the cut and torso rotating in the opposite direction to the cut, may place an athlete at higher risk of injury because these knee loads have been shown to increase the strain on the anterior cruciate ligament. Training athletes to avoid such body positions may result in a reduced risk of noncontact anterior cruciate ligament injures.

  20. Biomimetic fetal rotation bioreactor for engineering bone tissues-Effect of cyclic strains on upregulation of osteogenic gene expression.

    PubMed

    Ravichandran, Akhilandeshwari; Wen, Feng; Lim, Jing; Chong, Mark Seow Khoon; Chan, Jerry K Y; Teoh, Swee-Hin

    2018-04-01

    Cells respond to physiological mechanical stresses especially during early fetal development. Adopting a biomimetic approach, it is necessary to develop bioreactor systems to explore the effects of physiologically relevant mechanical strains and shear stresses for functional tissue growth and development. This study introduces a multimodal bioreactor system that allows application of cyclic compressive strains on premature bone grafts that are cultured under biaxial rotation (chamber rotation about 2 axes) conditions for bone tissue engineering. The bioreactor is integrated with sensors for dissolved oxygen levels and pH that allow real-time, non-invasive monitoring of the culture parameters. Mesenchymal stem cells-seeded polycaprolactone-β-tricalcium phosphate scaffolds were cultured in this bioreactor over 2 weeks in 4 different modes-static, cyclic compression, biaxial rotation, and multimodal (combination of cyclic compression and biaxial rotation). The multimodal culture resulted in 1.8-fold higher cellular proliferation in comparison with the static controls within the first week. Two weeks of culture in the multimodal bioreactor utilizing the combined effects of optimal fluid flow conditions and cyclic compression led to the upregulation of osteogenic genes alkaline phosphatase (3.2-fold), osteonectin (2.4-fold), osteocalcin (10-fold), and collagen type 1 α1 (2-fold) in comparison with static cultures. We report for the first time, the independent and combined effects of mechanical stimulation and biaxial rotation for bone tissue engineering using a bioreactor platform with non-invasive sensing modalities. The demonstrated results show leaning towards the futuristic vision of using a physiologically relevant bioreactor system for generation of autologous bone grafts for clinical implantation. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Laser-driven clockwise molecular rotation for a transient spinning waveplate.

    PubMed

    York, Andrew G

    2009-08-03

    Our simulations show a copropagating pair of laser pulses polarized in two different directions can selectively excite clockwise or counterclockwise molecular rotation in a gas of linear molecules. The resulting birefringence of the gas rotates on a femtosecond timescale and shows a periodic revival structure. The total duration of the pulse pair can be subpicosecond, allowing molecular alignment at the high densities and temperatures necessary to create a transient spinning waveplate.

  2. Implementation of formal learning objectives during a physical medicine and rehabilitation sports medicine rotation.

    PubMed

    Smith, Jay; Laskowski, Edward R; Newcomer-Aney, Karen L; Thompson, Jeffrey M; Schaefer, Michael P; Morfe, Erasmus G

    2005-04-01

    To develop and implement formal learning objectives during a physical medicine and rehabilitation sports medicine rotation and characterize resident experiences with the objectives over a 16-mo period. Prospective, including learning objective development, implementation, and postrotation survey. A total of 69 learning objectives were developed by physical medicine and rehabilitation staff physician consensus, including 39 core objectives. Eighteen residents completed 4-wk sports medicine rotations from January 2003 through April 2004. Residents completed an average of 31 total objectives (45%; range, 3-52), of which 24 (62%; range, 3-35) were core. Residents completed the highest percentage of knee (60%), shoulder (57%), and ankle-foot (57%) objectives and reported that objectives related to these areas were most effective to facilitate learning. In general, residents reported that objective content was good and that the objectives delineated important concepts to learn during the rotation. Seventeen of 18 residents indicated that the objectives should be permanently implemented into the sports rotation and that similar objectives should be developed for other rotations. Based on our experience and the recommendations of residents, the average resident should be able to complete approximately 30 objectives during a typical 4-wk rotation. Successful implementation of specific, consensus-derived learning objectives is possible within the context of a busy clinical practice. Our initial physician staff and resident experience with the objectives suggests that this model may be useful as a supplementary educational tool in physical medicine and rehabilitation residency programs.

  3. Navigation-based femorotibial rotation pattern correlated with flexion angle after total knee arthroplasty.

    PubMed

    Ishida, Kazunari; Shibanuma, Nao; Matsumoto, Tomoyuki; Sasaki, Hiroshi; Takayama, Koji; Matsuzaki, Tokio; Tei, Katsumasa; Kuroda, Ryosuke; Kurosaka, Masahiro

    2016-01-01

    To investigate whether intraoperative kinematics obtained by navigation systems can be divided into several kinematic patterns and to assess the correlation between the intraoperative kinematics with maximum flexion angles before and after total knee arthroplasty (TKA). Fifty-four posterior-stabilised (PS) TKA implanted using an image-free navigation system were evaluated. At registration and after implantation, tibial internal rotation angles at maximum extension, 30°, 45°, 60°, 90°, and maximum flexion were collected. The rotational patterns were divided into four groups and were examined the correlation with maximum flexion before and after operation. Tibial internal rotation from 90° of flexion to maximum flexion at registration was correlated with maximum flexion angles pre- and postoperatively. The four groups showed statistically different kinematic patterns. The group with tibial external rotation up to 90° of flexion, following tibial internal rotation at registration, achieved better flexion angles, compared to those of another groups (126.7° ± 12.0°, p < 0.05). The group with tibial external rotation showed the worst flexion angles (80.0° ± 40.4°, p < 0.05). Furthermore, the group with limited extension showed worse flexion angles (111.6° ± 8.9°, p < 0.05). Navigation-based kinematic patterns found at registration predict postoperative maximum flexion angle in PS TKA. Navigation-based kinematics can be useful information during TKA surgery. Diagnostic studies, development of diagnostic criteria in a consecutive series of patients and a universally applied "gold" standard, Level II.

  4. The geomorphic effect of recent storms - Quantifying meso scale abrasion across a shore platform

    NASA Astrophysics Data System (ADS)

    Cullen, Niamh; Bourke, Mary; Naylor, Larissa

    2017-04-01

    Boulder abrasion trails (BATs) are lineations on the surface of rock platforms formed by the movement of traction-load clasts by waves. They have been observed on a variety of platform lithologies, including limestone, granite and basalt. Despite previous reporting of these features, the abrasion styles and geomorphic work done by boulder transport has not been quantified. We present the first quantitative measurement of shore platform erosion by boulder transport during extreme storms that occurred in the winter of 2015-2016. Following two storm events in 2016 we mapped and measured 33 individual BATs on a sandstone platform on the west coast of Ireland. The total (minimum) abraded surface area was 10m2. The total (minimum) volume of material abraded was 0.2m3. In order to test the efficacy of this process during non-storm conditions we conducted field experiments on the same platform. We identified two sites on the platform that were similar, but differed in their intertidal roughness. We installed an RBR solo wave pressure transducer (PT) at 0m OD at both locations to record wave data. We measured platform roughness, determined as the fractal dimension of the platform profiles at both sites. We deployed an array of boulders of known dimensions and mass, parallel to the shoreline at 0.5m intervals from the PTs. The experiments were conducted 1. during relatively calm conditions and 2. during higher energy conditions. Data was collected for one tidal cycle. Any boulder displacement distance and direction was measured and geomorphic effects were documented. We find that BATs are formed under a range of wave energy conditions. Our observations indicate that along the North Atlantic coastline, BATs can occur at a high frequency, only limited by sediment supply. Our data show that abrasion by boulder transport is a potentially significant geomorphological process acting to abrade platforms under contemporary climate conditions. In addition, our preliminary findings suggest that platform roughness exerts a strong influence on wave energy and potential boulder transport. We find that abrasion of the platform surface is a fundamentally important process which contributes to lowering of the platform surface over time.

  5. STS-27 Atlantis, Orbiter Vehicle (OV) 104, at KSC Launch Complex (LC) pad 39B

    NASA Technical Reports Server (NTRS)

    1988-01-01

    STS-27 Atlantis, Orbiter Vehicle (OV) 104, sits atop the mobile launcher platform at Kennedy Space Center (KSC) Launch Complex (LC) pad 39B. Profile of OV-104 mounted on external tank and flanked by solid rocket boosters (SRBs) is obscured by a flock of seagulls in the foreground. The fixed service structure (FSS) with rotating service structure (RSS) retracted appears in the background. Water resevoir is visible at the base of the launch pad concrete structure.

  6. Angular sensitivities of scintillator slab configurations for location of gamma ray bursts

    NASA Technical Reports Server (NTRS)

    Gregory, J. C.

    1976-01-01

    Thin flat scintillator slabs are a useful means of measuring the angular location of gamma ray fluxes of astronomical interest. A statistical estimate of position error was made of two scintillator systems suitable for gamma ray burst location from a balloon or satellite platform. A single rotating scintillator with associated flux monitor is compared with a pair of stationary orthogonal scintillators. Position error for a strong burst is of the order of a few arcmin if systematic errors are ignored.

  7. SSTAC/ARTS review of the draft Integrated Technology Plan (ITP). Volume 6: Controls and guidance

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Viewgraphs of briefings from the Space Systems and Technology Advisory Committee (SSTAC)/ARTS review of the draft Integrated Technology Plan (ITP) on controls and guidance are included. Topics covered include: strategic avionics technology planning and bridging programs; avionics technology plan; vehicle health management; spacecraft guidance research; autonomous rendezvous and docking; autonomous landing; computational control; fiberoptic rotation sensors; precision instrument and telescope pointing; microsensors and microinstruments; micro guidance and control initiative; and earth-orbiting platforms controls-structures interaction.

  8. Control of Crazyflie nano quadcopter using Simulink

    NASA Astrophysics Data System (ADS)

    Gopabhat Madhusudhan, Meghana

    This thesis focuses on developing a mathematical model in Simulink to Crazyflie, an open source platform. Attitude, altitude and position controllers of a Crazyflie are designed in the mathematical model. The mathematical model is developed based on the quadcopter system dynamics using a non-linear approach. The parameters of translational and rotational dynamics of the quadcopter system are linearized and tuned individually. The tuned attitude and altitude controllers from the mathematical model are implemented on real time Crazyflie Simulink model to achieve autonomous and controlled flight.

  9. [Anthropogenic sources of radiation hazard in the near-Earth space].

    PubMed

    Fedoseev, G A

    2004-01-01

    All plausible artificial radioactive sources entering the near-Earth space (NES) were systematized and consequences of various large radiation accidents and catastrophes to Earth and NES were analyzed. Aggressive "population" of near-Earth orbits by space stations with rotating crews, unmanned research platforms and observatories extends "borderlines" of the noosphere raising at the same time concerns about the noosphere radiation safety and global radioecology. Specifically, consideration is given to the facts of negative effects of space power reactor facilities on results of orbital astrophysical investigations.

  10. PKPass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adamson, Ryan M.

    Password management solutions exist, but few are designed for enterprise systems administrators sharing oncall rotations. Due to the Multi-Factor Level of Assurance 4 effort, DOE is now distributing PIV cards with cryptographically signed certificate and private key pairs to administrators and other security-significant users. We utilize this public key infrastructure (PKI) to encrypt passwords for other recipients in a secure way. This is cross platform (works on OSX and Linux systems), and has already been adopted internally by the NCCS systems administration staff to replace their old password book system.

  11. Development and Testing of a Hybrid Wheg (trademark)-Mobile Platform for Autonomous Surf-Zone Operations

    DTIC Science & Technology

    2011-12-01

    7 Figure 2.1 Force body diagram of a wheel. . . . . . . . . . . . . . . . . . . . . . 9 Figure 2.2 Force body diagram of a person climbing stairs ...person climbing stairs . . . . . 10 Figure 2.4 Plot of the height of center above ground vs. rotation angle for a wheel and Wheg...tail was able to climb an obstacle six centimeters higher than a similar robot with six Whegs [6].The addition of a tail shifted the center of mass

  12. Operations and maintenance manual for the linear accelerator (sled)

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The Linear Accelerator, a sliding chair which is pulled along a stationary platform in a horizontal axis is described. The driving force is a motor controlled by a velocity loop amplifier, and the mechanical link to the chair is a steel cable. The chair is moved in forward and reverse directions as indicated by the direction of motor rotation. The system operation is described with emphasis on the electronic control and monitoring functions. Line-by-line schematics and wire lists are included.

  13. Anatomical glenohumeral internal rotation deficit and symmetric rotational strength in male and female young beach volleyball players.

    PubMed

    Saccol, Michele Forgiarini; Almeida, Gabriel Peixoto Leão; de Souza, Vivian Lima

    2016-08-01

    Beach volleyball is a sport with a high demand of shoulder structures that may lead to adaptations in range of motion (ROM) and strength like in other overhead sports. Despite of these possible alterations, no study evaluated the shoulder adaptations in young beach volleyball athletes. The aim of this study was to compare the bilateral ROM and rotation strength in the shoulders of young beach volleyball players. Goniometric passive shoulder ROM of motion and isometric rotational strength were evaluated in 19 male and 14 female asymptomatic athletes. External and internal ROM, total rotation motion, glenohumeral internal rotation deficit (GIRD), external rotation and internal rotation strength, bilateral deficits and external rotation to internal rotation ratio were measured. The statistical analysis included paired Student's t-test and analysis of variance with repeated measures. Significantly lower dominant GIRD was found in both groups (p<0.05), but only 6 athletes presented pathological GIRD. For strength variables, no significant differences for external or internal rotation were evident. Young beach volleyball athletes present symmetric rotational strength and shoulder ROM rotational adaptations that can be considered as anatomical. These results indicate that young practitioners of beach volleyball are subject to moderate adaptations compared to those reported for other overhead sports. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Latissimus dorsi transfer to restore external rotation with reverse shoulder arthroplasty: a biomechanical study.

    PubMed

    Favre, Philippe; Loeb, Michael D; Helmy, Naeder; Gerber, Christian

    2008-01-01

    In patients with pseudoparesis of the shoulder resulting from irreparable rotator cuff tears, reverse shoulder arthroplasty (RSA) can restore active elevation, but external rotation remains less predictable. Latissimus dorsi transfer (LDT) has been shown to be effective in restoring external rotation in patients with posterosuperior tears of the rotator cuff. The aim of this study is to determine the capacity of the LDT to restore external rotation in combination with RSA and to investigate the mechanical advantage produced by 3 different insertion sites. A biomechanical model was created using a reverse total shoulder prosthesis with 3 different transfer insertions. Moment arms were measured for 2 static positions and 1 motion of the humerus. The moment arm analysis showed that LDT can improve active external rotation in the setting of a reverse prosthesis. An insertion site on the posterior side of the greater tuberosity (adjacent to the teres minor insertion) produced a greater external rotation moment arm.

  15. Water table management reduces tile nitrate loss in continuous corn and in a soybean-corn rotation.

    PubMed

    Drury, C F; Tan, C S; Gaynor, J D; Reynolds, W D; Welacky, T W; Oloya, T O

    2001-10-25

    Water table management systems can be designed to alleviate soil water excesses and deficits, as well as reduce nitrate leaching losses in tile discharge. With this in mind, a standard tile drainage (DR) system was compared over 8 years (1991 to 1999) to a controlled tile drainage/subirrigation (CDS) system on a low-slope (0.05 to 0.1%) Brookston clay loam soil (Typic Argiaquoll) in southwestern Ontario, Canada. In the CDS system, tile discharge was controlled to prevent excessive drainage, and water was pumped back up the tile lines (subirrigation) to replenish the crop root zone during water deficit periods. In the first phase of the study (1991 to 1994), continuous corn (Zea mays, L.) was grown with annual nitrogen (N) fertilizer inputs as per local soil test recommendations. In the second phase (1995 to 1999), a soybean (Glycine max L., Merr.)-corn rotation was used with N fertilizer added only during the two corn years. In Phase 1 when continuous corn was grown, CDS reduced total tile discharge by 26% and total nitrate loss in tile discharge by 55%, compared to DR. In addition, the 4-year flow weighted mean (FWM) nitrate concentration in tile discharge exceeded the Canadian drinking water guideline (10 mg N l(-1)) under DR (11.4 mg N l(-1)), but not under CDS (7.0 mg N l(-1)). In Phase 2 during the soybean-corn rotation, CDS reduced total tile discharge by 38% and total nitrate loss in tile discharge by 66%, relative to DR. The 4-year FWM nitrate concentration during Phase 2 in tile discharge was below the drinking water guideline for both DR (7.3 mg N l(-1)) and CDS (4.0 mg N l(-1)). During both phases of the experiment, the CDS treatment caused only minor increases in nitrate loss in surface runoff relative to DR. Hence CDS decreased FWM nitrate concentrations, total drainage water loss, and total nitrate loss in tile discharge relative to DR. In addition, soybean-corn rotation reduced FWM nitrate concentrations and total nitrate loss in tile discharge relative to continuous corn. CDS and crop rotations with reduced N fertilizer inputs can thus improve the quality of tile discharge water substantially.

  16. Platform C South Arrival

    NASA Image and Video Library

    2016-08-05

    A heavy load transport truck from Tillett Heavy Hauling in Titusville, Florida, arrives at the Vehicle Assembly Building (VAB) at NASA’s Kennedy Space Center in Florida, carrying the second section of the first half of the C-level work platforms, C South, for the agency’s Space Launch System (SLS) rocket. The platform will be offloaded in the VAB staging area in the west parking lot. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to VAB High Bay 3 to support processing of the SLS and Orion spacecraft. A total of 10 levels of new platforms, 20 platform halves altogether, will surround the SLS rocket and Orion spacecraft and provide access for testing and processing.

  17. Platform C South Arrival

    NASA Image and Video Library

    2016-08-04

    A heavy load transport truck from Tillett Heavy Hauling in Titusville, Florida, arrives at the Vehicle Assembly Building (VAB) at NASA’s Kennedy Space Center in Florida, carrying a section of the first half of the C-level work platforms, C south, for the agency’s Space Launch System (SLS) rocket. The platform will be delivered to the VAB staging area in the west parking lot. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to VAB High Bay 3 to support processing of the SLS and Orion spacecraft. A total of 10 levels of new platforms, 20 platform halves altogether, will surround the SLS rocket and Orion spacecraft and provide access for testing and processing.

  18. VAB Platform K(2) Lift & Install into Highbay 3

    NASA Image and Video Library

    2016-03-07

    Work is underway to secure the second half of the K-level work platforms for NASA’s Space Launch System (SLS) rocket in High Bay 3 inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida. The platform is being secured into position on tower E, about 86 feet above the floor. The K work platforms will provide access to NASA's Space Launch System (SLS) core stage and solid rocket boosters during processing and stacking operations on the mobile launcher. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to High Bay 3 to support processing of the SLS and Orion spacecraft. A total of 10 levels of new platforms, 20 platform halves altogether, will surround the SLS rocket and Orion spacecraft.

  19. VAB Platform K(2) Lift & Install into Highbay 3

    NASA Image and Video Library

    2016-03-07

    A 250-ton crane is used to lower the second half of the K-level work platforms for NASA’s Space Launch System (SLS) rocket into High Bay 3 inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida. The platform will be secured about 86 feet above the VAB floor, on tower E of the high bay. The K work platforms will provide access to the SLS core stage and solid rocket boosters during processing and stacking operations on the mobile launcher. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to High Bay 3 to support processing of the SLS and Orion spacecraft. A total of 10 levels of new platforms, 20 platform halves altogether, will surround the SLS rocket and Orion spacecraft.

  20. Nonlinear Finite Element Analysis of a General Composite Shell

    DTIC Science & Technology

    1988-12-01

    strain I Poisson’s ratio ix I I iI I I 1 Total potential energy a Normal stress rShear stress Rotational terms Distance from midsurface e ,Y ,0 Rotations...respectively 0 0 Subscript "e" indicates element reference Subscript "g" indicates global reference Superscript "o" indicates midsurface values...surface strains and rotations are small, and displacements away from the midsurface are restricted by the Kirchhoff-Love hypotheses [3]. With these

  1. Bracing can partially limit tibial rotation during stressful activities after anterior crucial ligament reconstruction with a hamstring graft.

    PubMed

    Giotis, D; Paschos, N K; Zampeli, F; Pappas, E; Mitsionis, G; Georgoulis, A D

    2016-09-01

    Hamstring graft has substantial differences with BPTB graft regarding initial mechanical strength, healing sequence, and vascularization, which may imply that a different approach during rehabilitation period is required. The purpose of this study was to investigate the influence of knee bracing on tibial rotation in ACL-reconstructed patients with a hamstring autograft during high loading activities. The hypothesis was that there would be a decrease in tibial rotation in the ACL-reconstructed braced knee as compared to the unbraced knee. Twenty male patients having undergone unilateral ACL reconstruction with a semitendinosus/gracilis autograft were assessed. Kinematic data were collected with an eight-camera optoelectronic system during two stressful tasks: (1) descending from a stair and subsequent pivoting; and (2) landing from a platform and subsequent pivoting. In each patient, three different experimental conditions were evaluated: (A) wearing a prophylactic brace (braced condition); (B) wearing a patellofemoral brace (sleeved condition); (C) without brace (unbraced condition). The intact knee without brace served as a control. Tibial rotation was significantly lower in the intact knee compared to all three conditions of the ACL-reconstructed knee (P≤0.01 for both tasks). Presence of a brace or sleeve resulted in lower tibial rotation than in the unbraced condition (p=0.003 for descending/pivot and P=0.0004 for landing/pivot). The braced condition resulted in lower rotation than the sleeved condition for descending/pivoting (P=0.031) while no differences were found for landing/pivoting (P=0.230). Knee bracing limited the excessive tibial rotation during pivoting under high loading activities in ACL-reconstructed knees with a hamstring graft. This partial restoration of normal kinematics may have a potential beneficial effect in patients recovering from ACL reconstruction with a hamstring autograft. Level III, case-control therapeutic study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  2. Integrated polymer polarization rotator based on tilted laser ablation

    NASA Astrophysics Data System (ADS)

    Poulopoulos, Giannis; Kalavrouziotis, Dimitrios; Missinne, Jeroen; Bosman, Erwin; Van Steenberge, Geert; Apostolopoulos, Dimitrios; Avramopoulos, Hercules

    2017-02-01

    The ubiquitous need for compact, low-cost and mass production photonic devices, for next generation photonic enabled applications, necessitates the development of integrated components exhibiting functionalities that are, to date, carried out by free space elements or standard fiber equipment. The polarization rotator is a typical example of such tendency, as it is a crucial part of the PBS operation of future transceiver modules that leverage polarization multiplexing schemes for increasing the optical network capacity. Up to now, a variety of integrated polarization rotating concepts has been proposed and reported, relying, mainly, on special waveguide crossection configurations for achieving the rotation. Nevertheless, most of those concepts employ SiPh or III-V integration platforms, significantly increasing the fabrication complexity required for customizing the waveguide crossection, which in turn leads to either prohibitively increased cost or compromised quality and performance. In this manuscript we demonstrate the extensive design of a low-cost integrated polymer polarization rotator employing a right-trapezoidal waveguide interfaced to standard square polymer waveguides. First the crossection of the waveguide is defined by calculating and analyzing the components of the hybrid modes excited in the waveguide structure, using a Finite Difference mode solver. Mode overlaps between the fundamental polymer mode and each hybrid mode reveal the optimum lateral offset between the square polymer and the trapezoidal waveguide that ensures both minimum interface loss and maximized polarization rotation performance. The required trapezoidal waveguide length is obtained through EigenMode Expansion (EME) propagation simulations, while more than 95% maximum theoretical conversion efficiency is reported over the entire C-band, resulting to more than 13dB polarization extinction ratio. The polarization rotator design relies on the development of angled polymer waveguide sidewalls, employing the tilted laser ablation technology, currently available at CMST. Therefore, the aforementioned simulation steps adhere fully to the respective design rules, taking into account the anticipated fabrication variations

  3. Significant association of full-thickness rotator cuff tears and estrogen-related receptor-β (ESRRB).

    PubMed

    Teerlink, Craig C; Cannon-Albright, Lisa A; Tashjian, Robert Z

    2015-02-01

    The precise etiology of rotator cuff disease is unknown, but prior evidence suggests a role for genetic factors. Variants of estrogen-related receptor-β (ESRRB) have been previously associated with rotator cuff disease. The purpose of the present study was to confirm the association between multiple candidate genes, including ESRRB, and rotator cuff disease in an independent set of patients with rotator cuff tear. The Illumina 5M (Illumina Inc, San Diego, CA, USA) single nucleotide polymorphism (SNP) platform was used to genotype 175 patients with rotator cuff tear. Genotypes were used to select a set of 2595 genetically matched Caucasian controls available from the Illumina iControls database. Tests of association were performed with Genome-wide Efficient Mixed Model Association (GEMMA) software at 69 SNPs that fell within 20 kb of 6 candidate genes (DEFB1, DENND2C, ESRRB, FGF3, FGF10, and FGFR1). Tests of association revealed 1 significantly associated SNP occurring in ESRRB (rs17583842; P = 4.4E-4). Another SNP within ESRRB (rs7157192) had a nominal P value of 7.8E-3. FastPHASE software estimated 2 frequent haplotypes among 54 individuals who carried both risk alleles at these 2 SNPs. The first haplotype had a frequency of 13.9% (n = 15) in risk-allele carriers and only 2.2% in controls (odds ratio, 6.9; 95% confidence interval, 3.9-2.2). The second haplotype had a frequency of 12.9% in risk-allele carriers and only 2.7% in controls (odds ratio, 5.3; 95% confidence interval, 3.0-9.5). The significant association and the presence of high-risk haplotypes identified in the ESRRB gene confirm the association of variants in ESRRB and rotator cuff disease. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  4. Development of a Mechanical Scanning Device With High-Frequency Ultrasound Transducer for Ultrasonic Capsule Endoscopy.

    PubMed

    Wang, Xingying; Seetohul, Vipin; Chen, Ruimin; Zhang, Zhiqiang; Qian, Ming; Shi, Zhehao; Yang, Ge; Mu, Peitian; Wang, Congzhi; Huang, Zhihong; Zhou, Qifa; Zheng, Hairong; Cochran, Sandy; Qiu, Weibao

    2017-09-01

    Wireless capsule endoscopy has opened a new era by enabling remote diagnostic assessment of the gastrointestinal tract in a painless procedure. Video capsule endoscopy is currently commercially available worldwide. However, it is limited to visualization of superficial tissue. Ultrasound (US) imaging is a complementary solution as it is capable of acquiring transmural information from the tissue wall. This paper presents a mechanical scanning device incorporating a high-frequency transducer specifically as a proof of concept for US capsule endoscopy (USCE), providing information that may usefully assist future research. A rotary solenoid-coil-based motor was employed to rotate the US transducer with sectional electronic control. A set of gears was used to convert the sectional rotation to circular rotation. A single-element focused US transducer with 39-MHz center frequency was used for high-resolution US imaging, connected to an imaging platform for pulse generation and image processing. Key parameters of US imaging for USCE applications were evaluated. Wire phantom imaging and tissue phantom imaging have been conducted to evaluate the performance of the proposed method. A porcine small intestine specimen was also used for imaging evaluation in vitro. Test results demonstrate that the proposed device and rotation mechanism are able to offer good image resolution ( [Formula: see text]) of the lumen wall, and they, therefore, offer a viable basis for the fabrication of a USCE device.

  5. Influence of Medial Collateral Ligament Release for Internal Rotation of Tibia in Posterior-Stabilized Total Knee Arthroplasty: A Cadaveric Study.

    PubMed

    Wada, Keizo; Hamada, Daisuke; Tamaki, Shunsuke; Higashino, Kosaku; Fukui, Yoshihiro; Sairyo, Koichi

    2017-01-01

    Previous studies suggested that changes in kinematics in total knee arthroplasty (TKA) affected satisfaction level. The aim of this cadaveric study was to evaluate the effect of medial collateral ligament (MCL) release by multiple needle puncture on knee rotational kinematics in posterior-stabilized TKA. Six fresh, frozen cadaveric knees were included in this study. All TKA procedures were performed with an image-free navigation system using a 10-mm polyethylene insert. Tibial internal rotation was assessed to evaluate intraoperative knee kinematics. Multiple needle puncturing was performed 5, 10, and 15 times for the hard portion of the MCL at 90° knee flexion. Kinematic analysis was performed after every 5 punctures. After performing 15 punctures, a 14-mm polyethylene insert was inserted, and kinematic analysis was performed. The tibial internal rotation angle at maximum knee flexion without multiple needle puncturing was significantly larger (9.42°) than that after 15 punctures (3°). Negative correlation (Pearson r = -0.715, P < .001) between tibial internal rotation angle at maximum knee flexion and frequency of puncture was observed. The tibial internal rotation angle with a 14-mm insert was significantly larger (7.25°) compared with the angle after 15 punctures. Tibial internal rotation during knee flexion was reduced by extensive MCL release using multiple needle puncturing and was recovered by increasing of medial tightness. From the point of view of knee kinematics, medial tightness should be allowed to maintain the internal rotation angle of the tibia during knee flexion which might lead to patient satisfaction. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. A biomechanical investigation of dual growing rods used for fusionless scoliosis correction.

    PubMed

    Quick, M E; Grant, C A; Adam, C J; Askin, G N; Labrom, R D; Pearcy, M J

    2015-01-01

    The use of dual growing rods is a fusionless surgical approach to the treatment of early onset scoliosis which aims to harness potential growth and correct spinal deformity. The purpose of this study was to compare the in-vitro biomechanical response of two different dual rod designs under axial rotation loading. Six porcine spines were dissected into seven level thoracolumbar multi-segment units. Each specimen was mounted and tested in a biaxial Instron machine, undergoing nondestructive left and right axial rotation to peak moments of 4 Nm at a constant rotation rate of 8 deg. s(-1). A motion tracking system (Optotrak) measured 3D displacements of individual vertebrae. Each spine was tested in an un-instrumented state first and then with appropriately sized semi-constrained and 'rigid' growing rods in alternating sequence. The range of motion, neutral zone size and stiffness were calculated from the moment-rotation curves and intervertebral range of motion was calculated from Optotrak data. Irrespective of test sequence, rigid rods showed a significant reduction of total rotation across all instrumented levels (with increased stiffness) whilst semi-constrained rods exhibited similar rotational behavior to the un-instrumented spines (P<0.05). An 11.1% and 8.0% increase in stiffness for left and right axial rotation respectively and 14.9% reduction in total range of motion were recorded with dual rigid rods compared with semi-constrained rods. Based on these findings, the Semi-constrained growing rods were shown to not increase axial rotation stiffness compared with un-instrumented spines. This is thought to provide a more physiological environment for the growing spine compared to dual rigid rod constructs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Percutaneous Vertebroplasty: Preliminary Experiences with Rotational Acquisitions and 3D Reconstructions for Therapy Control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hodek-Wuerz, Roman; Martin, Jean-Baptiste; Wilhelm, Kai

    Percutaneous vertebroplasty (PVP) is carried out under fluoroscopic control in most centers. The exclusion of implant leakage and the assessment of implant distribution might be difficult to assess based on two-dimensional radiographic projection images only. We evaluated the feasibility of performing a follow-up examination after PVP with rotational acquisitions and volumetric reconstructions in the angio suite. Twenty consecutive patients underwent standard PVP procedures under fluoroscopic control. Immediate postprocedure evaluation of the implant distribution in the angio suite (BV 3000; Philips, The Netherlands) was performed using rotational acquisitions (typical parameters for the image acquisition included a 17-cm field-of-view, 200 acquired imagesmore » for a total angular range of 180{sup o}). Postprocessing of acquired volumetric datasets included multiplanar reconstruction (MPR), maximum intensity projection (MIP), and volume rendering technique (VRT) images that were displayed as two-dimensional slabs or as entire three-dimensional volumes. Image evaluation included lesion and implant assessment with special attention given to implant leakage. Findings from rotational acquisitions were compared to findings from postinterventional CT. The time to perform and to postprocess the rotational acquisitions was in all cases less then 10 min. Assessment of implant distribution after PVP using rotational image acquisition methods and volumetric reconstructions was possible in all patients. Cement distribution and potential leakage sites were visualized best on MIP images presented as slabs. From a total of 33 detected leakages with CT, 30 could be correctly detected by rotational image acquisition. Rotational image acquisitions and volumetric reconstruction methods provided a fast method to control radiographically the result of PVP in our cases.« less

  8. Emission-angle and polarization-rotation effects in the lensed CMB

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lewis, Antony; Hall, Alex; Challinor, Anthony, E-mail: antony@cosmologist.info, E-mail: ahall@roe.ac.uk, E-mail: a.d.challinor@ast.cam.ac.uk

    Lensing of the CMB is an important effect, and is usually modelled by remapping the unlensed CMB fields by a lensing deflection. However the lensing deflections also change the photon path so that the emission angle is no longer orthogonal to the background last-scattering surface. We give the first calculation of the emission-angle corrections to the standard lensing approximation from dipole (Doppler) sources for temperature and quadrupole sources for temperature and polarization. We show that while the corrections are negligible for the temperature and E-mode polarization, additional large-scale B-modes are produced with a white spectrum that dominates those from post-Bornmore » field rotation (curl lensing). On large scales about one percent of the total lensing-induced B-mode amplitude is expected to be due to this effect. However, the photon emission angle does remain orthogonal to the perturbed last-scattering surface due to time delay, and half of the large-scale emission-angle B modes cancel with B modes from time delay to give a total contribution of about half a percent. While not important for planned observations, the signal could ultimately limit the ability of delensing to reveal low amplitudes of primordial gravitational waves. We also derive the rotation of polarization due to multiple deflections between emission and observation. The rotation angle is of quadratic order in the deflection angle, and hence negligibly small: polarization typically rotates by less than an arcsecond, orders of magnitude less than a small-scale image rotates due to post-Born field rotation (which is quadratic in the shear). The field-rotation B modes dominate the other effects on small scales.« less

  9. Development of a finite element model of the ligamentous cervical vertebral column of a Great Dane.

    PubMed

    Bonelli, Marília de Albuquerque; Shah, Anoli; Goel, Vijay; Costa, Fabiano Séllos; da Costa, Ronaldo Casimiro

    2018-06-01

    Cervical spondylomyelopathy (CSM), also known as wobbler syndrome, affects mainly large and giant-breed dogs, causing compression of the cervical spinal cord and/or nerve roots. Structural and dynamic components seem to play a role in the development of CSM; however, pathogenesis is not yet fully understood. Finite element models have been used for years in human medicine to study the dynamic behavior of structures, but it has been mostly overlooked in veterinary studies. To our knowledge, no specific ligamentous spine models have been developed to investigate naturally occurring canine myelopathies and possible surgical treatments. The goal of this study was to develop a finite element model (FEM) of the C 2 -C 7 segment of the ligamentous cervical vertebral column of a neurologically normal Great Dane without imaging changes. The FEM of the intact C 2 -C 7 cervical vertebral column had a total of 188,906 elements (175,715 tetra elements and 12,740 hexa elements). The range of motion (in degrees) for the FEM subjected to a moment of 2Nm was approximately 27.94 in flexion, 25.86 in extension, 24.14 in left lateral bending, 25.27 in right lateral bending, 17.44 in left axial rotation, and 16.72 in right axial rotation. We constructed a ligamentous FEM of the C 2 -C 7 vertebral column of a Great Dane dog, which can serve as a platform to be modified and adapted for studies related to biomechanics of the cervical vertebral column and to further improve studies on osseous-associated cervical spondylomyelopathy. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. VAB Platform K(2) Lift & Install into Highbay 3

    NASA Image and Video Library

    2016-03-07

    A 250-ton crane is used to lift the second half of the K-level work platforms for NASA’s Space Launch System (SLS) rocket high above the transfer aisle inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida. The platform is being lifted up for transfer into High Bay 3 for installation. The platform will be secured about 86 feet above the VAB floor, on tower E of the high bay. The K work platforms will provide access to the SLS core stage and solid rocket boosters during processing and stacking operations on the mobile launcher. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to High Bay 3 to support processing of the SLS and Orion spacecraft. A total of 10 levels of new platforms, 20 platform halves altogether, will surround the SLS rocket and Orion spacecraft.

  11. Fine-filter method for Raman lidar based on wavelength division multiplexing and fiber Bragg grating.

    PubMed

    Wang, Jun; Zheng, Jiao; Lu, Hong; Yan, Qing; Wang, Li; Liu, Jingjing; Hua, Dengxin

    2017-11-01

    Atmospheric temperature is one of the important parameters for the description of the atmospheric state. Most of the detection approaches to atmospheric temperature monitoring are based on rotational Raman scattering for better understanding atmospheric dynamics, thermodynamics, atmospheric transmission, and radiation. In this paper, we present a fine-filter method based on wavelength division multiplexing, incorporating a fiber Bragg grating in the visible spectrum for the rotational Raman scattering spectrum. To achieve high-precision remote sensing, the strong background noise is filtered out by using the secondary cascaded light paths. Detection intensity and the signal-to-noise ratio are improved by increasing the utilization rate of return signal form atmosphere. Passive temperature compensation is employed to reduce the temperature sensitivity of fiber Bragg grating. In addition, the proposed method provides a feasible solution for the filter system with the merits of miniaturization, high anti-interference, and high stability in the space-based platform.

  12. Testing single point incremental forming moulds for rotomoulding operations

    NASA Astrophysics Data System (ADS)

    Afonso, Daniel; de Sousa, Ricardo Alves; Torcato, Ricardo

    2017-10-01

    Low pressure polymer processes as thermoforming or rotational moulding use much simpler moulds than high pressure processes like injection. However, despite the low forces involved in the process, moulds manufacturing for these applications is still a very material, energy and time consuming operation. Particularly in rotational moulding there is no standard for the mould manufacture and very different techniques are applicable. The goal of this research is to develop and validate a method for manufacturing plastically formed sheet metal moulds by single point incremental forming (SPIF) for rotomoulding and rotocasting operations. A Stewart platform based SPIF machine allow the forming of thick metal sheets, granting the required structural stiffness for the mould surface, and keeping a short manufacture lead time and low thermal inertia. The experimental work involves the proposal of a hollow part, design and fabrication of a sheet metal mould using dieless incremental forming techniques and testing its operation in the production of prototype parts.

  13. Research on Operation Assessment Method for Energy Meter

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Huang, Rui; Shen, Liman; chen, Hao; Xiong, Dezhi; Xiao, Xiangqi; Liu, Mouhai; Xu, Renheng

    2018-03-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  14. A Method of Evaluating Operation of Electric Energy Meter

    NASA Astrophysics Data System (ADS)

    Chen, Xiangqun; Li, Tianyang; Cao, Fei; Chu, Pengfei; Zhao, Xinwang; Huang, Rui; Liu, Liping; Zhang, Chenglin

    2018-05-01

    The existing electric energy meter rotation maintenance strategy regularly checks the electric energy meter and evaluates the state. It only considers the influence of time factors, neglects the influence of other factors, leads to the inaccuracy of the evaluation, and causes the waste of resources. In order to evaluate the running state of the electric energy meter in time, a method of the operation evaluation of the electric energy meter is proposed. The method is based on extracting the existing data acquisition system, marketing business system and metrology production scheduling platform that affect the state of energy meters, and classified into error stability, operational reliability, potential risks and other factors according to the influencing factors, based on the above basic test score, inspecting score, monitoring score, score of family defect detection. Then, according to the evaluation model according to the scoring, we evaluate electric energy meter operating state, and finally put forward the corresponding maintenance strategy of rotation.

  15. Contribution of eye position to movement perception.

    PubMed

    Pettorossi, V E; Panichi, R; Bambagioni, D; Grassi, S; Botti, F M

    2004-05-01

    To investigate the influence of gaze eccentricity on movement perception during asymmetric vestibular stimulation. Subjects (n = 10) were placed on a rotating platform and oscillated asymmetrically in the dark. Subjects were asked to reproduce with a pointer the location in space of a light spot that was turned off at the beginning of the oscillation. The target was presented in centric and eccentric (0 degrees, 20 degrees and 40 degrees) positions. In the centric position a large shift from the real position of the target was observed in the opposite direction to that of the faster vestibular stimulation. The shift increased when the target was placed eccentrically toward the slower vestibular stimulation side and decreased when it was placed in the opposite direction. The dependence of rotation perception on the target position suggests that the eye deviation, imposed by the eccentricity of the target, is able to influence the perception of body movement and may modulate the internal reference frame.

  16. Resonantly driven CNOT gate for electron spins.

    PubMed

    Zajac, D M; Sigillito, A J; Russ, M; Borjans, F; Taylor, J M; Burkard, G; Petta, J R

    2018-01-26

    Single-qubit rotations and two-qubit CNOT operations are crucial ingredients for universal quantum computing. Although high-fidelity single-qubit operations have been achieved using the electron spin degree of freedom, realizing a robust CNOT gate has been challenging because of rapid nuclear spin dephasing and charge noise. We demonstrate an efficient resonantly driven CNOT gate for electron spins in silicon. Our platform achieves single-qubit rotations with fidelities greater than 99%, as verified by randomized benchmarking. Gate control of the exchange coupling allows a quantum CNOT gate to be implemented with resonant driving in ~200 nanoseconds. We used the CNOT gate to generate a Bell state with 78% fidelity (corrected for errors in state preparation and measurement). Our quantum dot device architecture enables multi-qubit algorithms in silicon. Copyright © 2018, The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  17. Pattern-free thermal modulator via thermal radiation between Van der Waals materials

    NASA Astrophysics Data System (ADS)

    Liu, Xianglei; Shen, Jiadong; Xuan, Yimin

    2017-10-01

    Modulating heat flux provides a platform for a plethora of emerging devices such as thermal diodes, thermal transistors, and thermal memories. Here, a pattern-free noncontact thermal modulator is proposed based on the mechanical rotation between two Van der Waals films with optical axes parallel to the surfaces. A modulation contrast can reach a value higher than 5 for hexagonal Boron Nitride (hBN) films separated by a nanoscale gap distance. The dominant radiative heat exchange comes from the excitation of both Type I and Type II hyperbolic surface phonon polaritons (HSPhPs) at the vacuum-hBN interface for different orientations, while the large modulation contrast is mainly attributed to the mismatching Type I HSPhPs induced by rotation. This work opens the possibility to design cheap thermal modulators without relying on nanofabrication techniques, and paves the way to apply natural Van der Waals materials in manipulating heat currents in an active way.

  18. Mental Rotation Ability and Computer Game Experience

    ERIC Educational Resources Information Center

    Gecu, Zeynep; Cagiltay, Kursat

    2015-01-01

    Computer games, which are currently very popular among students, can affect different cognitive abilities. The purpose of the present study is to examine undergraduate students' experiences and preferences in playing computer games as well as their mental rotation abilities. A total of 163 undergraduate students participated. The results showed a…

  19. A climatology of total ozone mapping spectrometer data using rotated principal component analysis

    NASA Astrophysics Data System (ADS)

    Eder, Brian K.; Leduc, Sharon K.; Sickles, Joseph E.

    1999-02-01

    The spatial and temporal variability of total column ozone (Ω) obtained from the total ozone mapping spectrometer (TOMS version 7.0) during the period 1980-1992 was examined through the use of a multivariate statistical technique called rotated principal component analysis. Utilization of Kaiser's varimax orthogonal rotation led to the identification of 14, mostly contiguous subregions that together accounted for more than 70% of the total Ω variance. Each subregion displayed statistically unique Ω characteristics that were further examined through time series and spectral density analyses, revealing significant periodicities on semiannual, annual, quasi-biennial, and longer term time frames. This analysis facilitated identification of the probable mechanisms responsible for the variability of Ω within the 14 homogeneous subregions. The mechanisms were either dynamical in nature (i.e., advection associated with baroclinic waves, the quasi-biennial oscillation, or El Niño-Southern Oscillation) or photochemical in nature (i.e., production of odd oxygen (O or O3) associated with the annual progression of the Sun). The analysis has also revealed that the influence of a data retrieval artifact, found in equatorial latitudes of version 6.0 of the TOMS data, has been reduced in version 7.0.

  20. Platform C South Arrival

    NASA Image and Video Library

    2016-08-05

    The second section of the first half of the C-level work platforms, C South, for NASA’s Space Launch System (SLS) rocket was offloaded from a heavy transport truck in a staging area on the west side of the Vehicle Assembly Building (VAB) at the agency’s Kennedy Space Center in Florida. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to VAB High Bay 3 to support processing of the SLS and Orion spacecraft. A total of 10 levels of new platforms, 20 platform halves altogether, will surround the SLS rocket and Orion spacecraft and provide access for testing and processing.

  1. Acceptability and Impact of a Required Palliative Care Rotation with Prerotation and Postrotation Observed Simulated Clinical Experience during Internal Medicine Residency Training on Primary Palliative Communication Skills.

    PubMed

    Vergo, Maxwell T; Sachs, Sharona; MacMartin, Meredith A; Kirkland, Kathryn B; Cullinan, Amelia M; Stephens, Lisa A

    2017-05-01

    Improving communication training for primary palliative care using a required palliative care rotation for internal medicine (IM) residents has not been assessed. To assess skills acquisition and acceptability for IM residents not selecting an elective. A consecutive, single-arm cohort underwent preobjective structured clinical examination (OSCE) with learner-centric feedback, two weeks of clinical experience, and finally a post-OSCE to crystallize learner-centric take home points. IM second year residents from Dartmouth-Hitchcock were exposed to a required experiential palliative care rotation. Pre- and post-OSCE using a standardized score card for behavioral skills, including patient-centered interviewing, discussing goals of care/code status, and responding to emotion, as well as a confidential mixed qualitative and quantitative evaluation of the experience. Twelve residents were included in the educational program (two were excluded because of shortened experiences) and showed statistically significant improvements in overall communication and more specifically in discussing code status and responding to emotions. General patient-centered interviewing skills were not significantly improved, but prerotation scores reflected pre-existing competency in this domain. Residents viewed the observed simulated clinical experience (OSCE) and required rotation as positive experiences, but wished for more opportunities to practice communication skills in real clinical encounters. A required palliative care experiential rotation flanked by OSCEs at our institution improved the acquisition of primary palliative care communication skills similarly to other nonclinical educational platforms, but may better meet the needs of the resident and faculty as well as address all required ACGME milestones.

  2. Development of a Rotating Human Research Facility

    NASA Technical Reports Server (NTRS)

    Mulenburg, Gerald M.; Caldwell, William F.; Tucker, John; Wade, Charles E. (Technical Monitor)

    1994-01-01

    A unique facility has been developed at the NASA Ames Research Center to provide scientists with unusual research opportunities at greater than Earth's gravity. In addition to its use for basic research, this facility will help provide answers to many of the questions posed by proponents of rotating human space vehicles. This paper describes the design and planned use of this facility, the Spaceflight Environmental Simulator. Using an existing 52-foot diameter cylindrical rotating platform design centrifuge, the revised facility design includes the provision of two human habitats for long duration studies of the effects of hypergravity. Up to four humans (per habitat) will be able to live at up to 2 G for as long as one month without stopping the centrifuge. Each habitat, constructed of lightweight honeycomb sandwich panels, is nominally 9 ft high x 11 ft wide x 25 1/2 ft long. A radial positioning system provides for positioning each habitat at a distance of 15 to 21 feet from the centrifuge's axis of rotation to the midpoint of the habitat's interior floor. As centrifugal acceleration changes with rotation rate, a habitat floor-mounted accelerometer signal provides automatic servo controlled adjustment of each habitat's angle of inclination to provide an environment for the habitat's crew and cargo in which the resultant gravity vector is normal to the habitat floor at all times. Design of the habitats and modifications to the centrifuge are complete, and are currently under construction. Design philosophy and operational rationale are presented along with complete descriptions of the facility and its systems.

  3. The molecular inventory around protostars: water, organic molecules, and the missing oxygen problem

    NASA Astrophysics Data System (ADS)

    Neufeld, David A.

    2018-06-01

    Massive star formation is accompanied by significant chemical evolution in the surrounding interstellar gas. Here, grains are heated up and icy mantles evaporate, releasing a rich inventory of water and organic molecules into the gas-phase within “hot core” regions surrounding massive protostars. Because molecules on the grain surface present broad infrared features without rotational structure, only the most abundant molecules can be identified unambiguously in the solid phase; once released into the gas-phase, however, where they are free to rotate, the constituents of grain mantles can be identified easily by means of rotational spectroscopy at millimeter and submillimeter wavelengths or through rovibrational spectroscopy in the mid-infrared. While observations of pure-rotational emission lines provide a broad view of hot core chemistry, absorption line spectroscopy of rovibrational transitions can probe the very hottest material closest to the protostar. With access to the mid-infrared spectral region from above 99% of Earth’s water vapor, SOFIA provides a unique platform for high-resolution rovibrational spectroscopy of water and organic molecules, many of which have vibrational transitions in the 5 – 8 micron spectral region that is unobservable from the ground. High spectral resolution is essential for disentangling the rotational structure and providing reliable measurements of the molecular column densities and temperatures. Future SOFIA observations will help elucidate the inventory of water and organic molecules around young protostars, and can address a puzzle related to the “oxygen budget” in the interstellar medium: surprisingly, the main interstellar reservoirs of the third-most abundant element in the Universe have yet to be identified.

  4. Characteristics of produced water discharged to the Gulf of Mexico hypoxiczone.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veil, J. A.; Kimmell, T. A.; Rechner, A. C.

    2005-08-24

    Each summer, an area of low dissolved oxygen (the hypoxic zone) forms in the shallow nearshore Gulf of Mexico waters from the Mississippi River Delta westward to near the Texas/Louisiana border. Most scientists believe that the leading contributor to the hypoxic zone is input of nutrients (primarily nitrogen and phosphorus compounds) from the Mississippi and Atchafalaya Rivers. The nutrients stimulate growth of phytoplankton. As the phytoplankton subsequently die, they fall to the bottom waters where they are decomposed by microorganisms. The decomposition process consumes oxygen in the bottom waters to create hypoxic conditions. Sources other than the two rivers mentionedmore » above may also contribute significant quantities of oxygen-demanding pollutants. One very visible potential source is the hundreds of offshore oil and gas platforms located within or near the hypoxic zone. Many of these platforms discharge varying volumes of produced water. However, only limited data characterizing oxygen demand and nutrient concentration and loading from offshore produced water discharges have been collected. No comprehensive and coordinated oxygen demand data exist for produced water discharges in the Gulf of Mexico. This report describes the results of a program to sample 50 offshore oil and gas platforms located within the Gulf of Mexico hypoxic zone. The program was conducted in response to a requirement in the U.S. Environmental Protection Agency (EPA) general National Pollutant Discharge Elimination System (NPDES) permit for offshore oil and gas discharges. EPA requested information on the amount of oxygen-demanding substances contained in the produced water discharges. This information is needed as inputs to several water quality models that EPA intends to run to estimate the relative contributions of the produced water discharges to the occurrence of the hypoxic zone. Sixteen platforms were sampled 3 times each at approximately one-month intervals to give an estimate of temporal variability. An additional 34 platforms were sampled one time. The 50 sampled platforms were scattered throughout the hypoxic zone to give an estimate of spatial variability. Each platform was sampled for biochemical oxygen demand (BOD), total organic carbon (TOC), nitrogen (ammonia, nitrate, nitrite, and total Kjeldahl nitrogen [TKN]), and phosphorus (total phosphorus and orthophosphate). In addition to these parameters, each sample was monitored for pH, conductivity, salinity, and temperature. The sampling provided average platform concentrations for each parameter. Table ES-1 shows the mean, median, maximum, and minimum for the sampled parameters. For some of the parameters, the mean is considerably larger than the median, suggesting that one or a few data points are much higher than the rest of the points (outliers). Chapter 4 contains an extensive discussion of outliers and shows how the sample results change if outliers are deleted from consideration. A primary goal of this study is to estimate the mass loading (lb/day) of each of the oxygen-demanding pollutants from the 50 platforms sampled in the study. Loading is calculated by multiplying concentrations by the discharge volume and then by a conversion factor to allow units to match. The loadings calculated in this study of 50 platforms represent a produced water discharge volume of about 176,000 bbl/day. The total amount of produced water generated in the hypoxic zone during the year 2003 was estimated as 508,000 bbl/day. This volume is based on reports by operators to the Minerals Management Service each year. It reflects the volume of produced water that is generated from each lease, not the volume that is discharged from each platform. The mass loadings from offshore oil and gas discharges to the entire hypoxic zone were estimated by multiplying the 50-platform loadings by the ratio of total water generated to 50-platform discharge volume. The loadings estimated for the 50 platforms and for the entire hypoxic zone are shown in Table ES-2. These estimates and the sampling data from 50 platforms represent the most complete and comprehensive effort ever undertaken to characterize the amount and potential sources of the oxygen demand in offshore oil and gas produced water discharges.« less

  5. Biodegradation in seawater of PAH and alkylphenols from produced water of a North Sea platform.

    PubMed

    Lofthus, Synnøve; Almås, Inger K; Evans, Peter; Pelz, Oliver; Brakstad, Odd Gunnar

    2018-09-01

    Operational planned discharges of produced water (PW) to the marine environment from offshore oil production installations, contain low concentrations of dispersed oil compounds, like polycyclic aromatic hydrocarbons (PAHs) and alkylated phenols (APs). Biotransformation in natural seawater (SW) of naphthalenes/PAHs and phenol/APs in field-collected PW from a North Sea platform was investigated in this biodegradation study. The PW was diluted in SW from a Norwegian fjord, and the biodegradation study was performed in slowly rotating carousels at 13 °C over a period of 62 days. Naphthalenes/PAHs and phenol/APs biotransformation was determined by first-order rate kinetics, after normalization against the recalcitrant biomarker 17α(H),21β(H)-Hopane. The results from this study showed total biotransformation half-lives ranging from 10 to 19 days for groups of naphthalenes and PAHs, while half-lives for APs (C0- to C9-alkylated) were 10-14 days. Biotransformation half-lives of single compounds ranged from 8 to >100 days for naphthalenes and PAHs (median 16 days), and from 5 to 70 days (median 15 days) for phenols and APs. Four of the tested PAHs (chrysene, benzo(b)fluoranthene, benzo(e)pyrene, benzo(g,h,i)perylene) and one AP (4-tert-butylphenol) showed biotransformation half-lives >50 days. This is one of a few studies that has investigated the potential for biodegradation of PW in natural SW. Methods and data from this study may be used as a part of Risk Based Approaches (RBA) for assessments of environmental fate of PW released to the marine environment and as part of the persistence related to risk. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  6. Microbial Monitoring of Common Opportunistic Pathogens by Comparing Multiple Real-Time PCR Platforms for Potential Space Applications

    NASA Technical Reports Server (NTRS)

    Oubre, Cherie M.; Birmele, Michele N.; Castro, Victoria A.; Venkateswaran, Kasthuri J.; Vaishampayan, Parag A.; Jones, Kathy U.; Singhal, Adesh; Johnston, Angela S.; Roman, Monserrate C.; Ozbolt, Tamra A.; hide

    2013-01-01

    Because the International Space Station is a closed environment with rotations of astronauts and equipment that each introduce their own microbial flora, it is necessary to monitor the air, surfaces, and water for microbial contamination. Current microbial monitoring includes labor- and time-intensive methods to enumerate total bacterial and fungal cells, with limited characterization, during in-flight testing. Although this culture-based method is sufficient for monitoring the International Space Station, on future long-duration missions more detailed characterization will need to be performed during flight, as sample return and ground characterization may not be available. At a workshop held in 2011 at NASA's Johnson Space Center to discuss alternative methodologies and technologies suitable for microbial monitoring for these long-term exploration missions, molecular-based methodologies such as polymerase chain reaction (PCR) were recommended. In response, a multi-center (Marshall Space Flight Center, Johnson Space Center, Jet Propulsion Laboratory, and Kennedy Space Center) collaborative research effort was initiated to explore novel commercial-off-the-shelf hardware options for space flight environmental monitoring. The goal was to evaluate quantitative or semi-quantitative PCR approaches for low-cost in-flight rapid identification of microorganisms that could affect crew safety. The initial phase of this project identified commercially available platforms that could be minimally modified to perform nominally in microgravity. This phase was followed by proof-of-concept testing of the highest qualifying candidates with a universally available challenge organism, Salmonella enterica. The analysis identified two technologies that were able to perform sample-to-answer testing with initial cell sample concentrations between 50 and 400 cells. In addition, the commercial systems were evaluated for initial flight safety and readiness.

  7. Visualization of molecular structures using HoloLens-based augmented reality

    PubMed Central

    Hoffman, MA; Provance, JB

    2017-01-01

    Biological molecules and biologically active small molecules are complex three dimensional structures. Current flat screen monitors are limited in their ability to convey the full three dimensional characteristics of these molecules. Augmented reality devices, including the Microsoft HoloLens, offer an immersive platform to change how we interact with molecular visualizations. We describe a process to incorporate the three dimensional structures of small molecules and complex proteins into the Microsoft HoloLens using aspirin and the human leukocyte antigen (HLA) as examples. Small molecular structures can be introduced into the HoloStudio application, which provides native support for rotating, resizing and performing other interactions with these molecules. Larger molecules can be imported through the Unity gaming development platform and then Microsoft Visual Developer. The processes described here can be modified to import a wide variety of molecular structures into augmented reality systems and improve our comprehension of complex structural features. PMID:28815109

  8. Micromechanical torsional digital-to-analog converter for open-loop angular positioning applications

    NASA Astrophysics Data System (ADS)

    Zhou, Guangya; Tay, Francis E. H.; Chau, Fook Siong; Zhao, Yi; Logeeswaran, VJ

    2004-05-01

    This paper reports a novel micromechanical torsional digital-to-analog converter (MTDAC), operated in open-loop with digitally controlled precise multi-level tilt angles. The MTDAC mechanism presented is analogous to that of an electrical binary-weighted-input digital-to-analog converter (DAC). It consists of a rigid tunable platform, an array of torsional microactuators, each operating in a two-state (on/off) mode, and a set of connection beams with binary-weighted torsional stiffnesses that connect the actuators to the platform. The feasibility of the proposed MTDAC mechanism was verified numerically by finite element simulations and experimentally with a commercial optical phase-shifting interferometric system. A prototype 2-bit MTDAC was implemented using the poly-MUMPS process achieving a full-scale output tilt angle of 1.92° with a rotation step of 0.64°. This mechanism can be configured for many promising applications, particularly in beam steering-based OXC switches.

  9. KSC-02pd0390

    NASA Image and Video Library

    2002-04-03

    KENNEDY SPACE CENTER, FLA. -- Space Shuttle Atlantis is revealed as the Rotating Service Structure rolls back into launch position. The RSS provides protected access to the orbiter for changeout and servicing of payloads at the pad. The structure has access platforms at five levels to provide access to the payload bay. The Shuttle rests on the Mobile Launcher Platform (MLP), which straddles the flame trench below. The flame trench is part of the Flame Deflector System that insulates pad structures from the intense heat of the launch. Above the golden external tank is the vent hood (known as the "beanie cap") at the end of the gaseous oxygen vent arm. Vapors are created as the liquid oxygen in the external tank boil off. The hood vents the gaseous oxygen vapors away from the Space Shuttle vehicle. Mission STS-110 is scheduled to launch April 4 on its 11-day mission to the International Space Station

  10. Voyager 2 Saturn encounter attitude and articulation control experience

    NASA Technical Reports Server (NTRS)

    Hill, M.

    1982-01-01

    A description is given of the Voyager Attitude and Articulation Control System (AACS). The complex series of maneuvers required for Voyager 2 during the near encounter period to obtain fields and particle data, track the limb of Saturn during the earth occultation period, and reflect the RF beam off the Saturnian ring system are discussed. It is noted that some of these maneuvers involved rotating the spacecraft simultaneously about multiple axes while maintaining accurate pointing of the scan platform, a first for interplanetary missions. Also described are two anomalies experienced by the AACS during the near encounter period. The first was the significant roll attitude error that occurred shortly after all axis inertial control and that continued to grow until celestial reacquisition. The second was that the scan platform slewing in the azimuth axis stopped midway through the near encounter. These anomalies are analyzed, and their effect on future missions is assessed.

  11. Generating a Crop Rotation Dataset for the U.S and its Application in Inferring Land Use Change Induced Wetland Losses in the Prairie Pothole Region

    NASA Astrophysics Data System (ADS)

    Sahajpal, R.; Zhang, X.; Izaurralde, R. C.; Hurtt, G. C.

    2013-12-01

    Agricultural management practices plays a major role in the global fluxes of greenhouse gases, soil carbon sequestration and production of ecosystem services. A key component of these practices are the crop rotations selected by the farmer. Here, we present an algorithm to create a crop rotation dataset for the U.S and demonstrate the tradeoffs between the number and accuracy of rotations comprising a state. To generate the rotations, we use the USDA Cropland Data Layer (CDL) available for the entire U.S at a resolution of 30 m from 2010 to 2012. Several studies have generated rotations simply by merging several years of CDL data, resulting in thousands of rotations per state. Alternatively, they tend to aggregate the rotations into a few predefined categories. This over simplification can lead to erroneous acreage values impacting both biogeochemical model estimates and land use change studies. Our algorithm uses the edit distance metric to combine similar rotations to obtain a product which retains the accuracy of CDL while minimizing the number of rotations. We find that 180 unique rotations are needed to represent the entire U.S with an accuracy exceeding 80% when compared to the underlying CDL datasets for rotations from 2010 to 2012. For the agriculturally important and diverse Western corn belt, the number of rotations needed to represent each state with an accuracy exceeding 90% when compared to the CDL dataset, ranges from 3 unique rotations for Iowa to more than 50 for North Dakota. As an application of the dataset, we examine the findings of Wright and Wimberly (1), who reported in a recent issue of PNAS that recent grassland conversion to corn and soybean cropping (GRCS) from 2006 to 2011 in the Prairie Pothole Region (PPR) is concentrated in the vicinity of wetlands. Their analysis implicitly assumes that all wetlands affected by GRCS in the PPR existed in or after 2006. However, the areal extent of wetlands was based on National Wetland Inventory maps, which were produced from aerial photography taken in the 1970s and 1980s. Thus, we conclude that Wright and Wimberly overestimated the total area of agricultural expansion through GRCS within 500 m of wetlands. Instead of attributing historical wetland conversion to recent land use changes in the PPR, here we provide separate estimates of wetland conversion from 1982 - 2007 and 2006 - 2011 using data from National Resources Inventory and rotations generated using CDL data from 2006 to 2011. We use the rotations generated using CDL data from 2006 to 2011, to estimate the total area of agricultural expansion through GRCS within 500 m of wetlands in the PPR. We find that the total grassland acreage in close proximity to wetlands that was converted to corn/soybean cropping between 2006 and 2011 was 58% of the nearly 400,000 ha estimated by Wright and Wimberly. While biofuel production impacts land use decisions, it is critical to use appropriate tools and datasets to inform our analysis of environmental impacts of these decisions, lest it divert our focus from other drivers of land use change. Reference: 1. Wright CK, Wimberly MC (2013) Recent land use change in the Western Corn Belt threatens grasslands and wetlands. PNAS.

  12. Investigation into three dimensional hip anatomy in anterior dislocation after THA. Influence of the position of the hip rotation centre.

    PubMed

    Sariali, Elhadi; Klouche, Shahnez; Mamoudy, Patrick

    2012-07-01

    The components position is a major factor under the surgeon's control in determining the risk of dislocation post total hip arthroplasty. The aim of this study was to investigate the proper three-dimensional components position including the centre of rotation in the case of anterior dislocation. Among 1764 consecutive patients who underwent total hip arthroplasty using a direct anterior approach, 27 experienced anterior dislocation. The three-dimensional hip anatomy was investigated in 12 patients who were paired with 12 patients from the same initial cohort who did not experience dislocation and also with 36 control patients with osteoarthritis. A pelvic Cartesian referential was defined to perform the acetabular analysis. The coordinates were expressed as percentages of the pelvic width, height and depth. The anteversion angles were measured. The hip centre of rotation was significantly shifted medially and posteriorly in the dislocation group when compared to the non-dislocation group and also to the control group. There was no significant difference in component angular position between the dislocation-group and the non-dislocation group. However, the stem anteversion in the dislocation group was increased in comparison to the mean natural femoral anteversion of the control group. A medial and posterior displacement of the hip rotation centre was found to correlate to anterior dislocation post total hip arthoplasty. These results suggest the importance of an accurate restoration of the centre of rotation, whilst avoiding an excessive acetabular reaming which may induce a medial and a posterior displacement. III comparative non randomised. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Insight into the process of product expulsion in cellobiohydrolase Cel6A from Trichoderma reesei by computational modeling.

    PubMed

    Huang, Houhou; Han, Fei; Guan, Shanshan; Qian, Mengdan; Wan, Yongfeng; Shan, Yaming; Zhang, Hao; Wang, Song

    2018-03-24

    Glycoside hydrolase cellulase family 6 from Trichoderma reesei (TrCel6A) is an important cellobiohydrolase to hydrolyze cellooligosaccharide into cellobiose. The knowledge of enzymatic mechanisms is critical for improving the conversion efficiency of cellulose into ethanol or other chemicals. However, the process of product expulsion, a key component of enzymatic depolymerization, from TrCel6A has not yet been described in detail. Here, conventional molecular dynamics and steered molecular dynamics (SMD) were applied to study product expulsion from TrCel6A. Tyr103 may be a crucial residue in product expulsion given that it exhibits two different posthydrolytic conformations. In one conformation, Tyr103 rotates to open the -3 subsite. However, Tyr103 does not rotate in the other conformation. Three different routes for product expulsion were proposed on the basis of the two different conformations. The total energy barriers of the three routes were calculated through SMD simulations. The total energy barrier of product expulsion through Route 1, in which Tyr103 does not rotate, was 22.2 kcal·mol -1 . The total energy barriers of product expulsion through Routes 2 and 3, in which Tyr103 rotates to open the -3 subsite, were 10.3 and 14.4 kcal·mol -1 , respectively. Therefore, Routes 2 and 3 have lower energy barriers than Route 1, and Route 2 is the thermodynamically optimal route for product expulsion. Consequently, the rotation of Tyr103 may be crucial for product release from TrCel6A. Results of this work have potential applications in cellulase engineering.

  14. Bone mineral density of the femoral neck in resurfacing hip arthroplasty

    PubMed Central

    Ovesen, Ole; Brixen, Kim; Varmarken, Jens-Erik; Overgaard, SØren

    2010-01-01

    Background and purpose Resurfacing total hip arthroplasty (RTHA) may preserve the femoral neck bone stock postoperatively. Bone mineral density (BMD) may be affected by the hip position, which might bias longitudinal studies. We investigated the dependency of BMD precision on type of ROI and hip position. Method We DXA-scanned the femoral neck of 15 resurfacing patients twice with the hip in 3 different rotations: 15° internal, neutral, and 15° external. For each position, BMD was analyzed with 3 surface area models. One model measured BMD in the total femoral neck, the second model divided the neck in two, and the third model had 6 divisions. Results When all hip positions were pooled, average coefficients of variation (CVs) of 3.1%, 3.6%, and 4.6% were found in the 1-, 2-, and 6-region models, respectively. The externally rotated hip position was less reproducible. When rotating in increments of 15° or 30°, the average CVs rose to 7.2%, 7.3%, and 12% in the 3 models. Rotation affected the precision most in the model that divided the neck in 6 subregions, predominantly in the lateral and distal regions. For larger-region models, some rotation could be allowed without compromising the precision. Interpretation If hip rotation is strictly controlled, DXA can reliably provide detailed topographical information about the BMD changes around an RTHA. As rotation strongly affects the precision of the BMD measurements in small regions, we suggest that a less detailed model should be used for analysis in studies where the leg position has not been firmly controlled. PMID:20367420

  15. [A sign of the rotational impact of the gunshot projectile on the flat bone].

    PubMed

    Leonov, S V

    2014-01-01

    The objective of the present work was to study the mechanisms of formation of the gunshot fracture of the flat bones with special reference to the translational and rotational motion of the projectile. A total of 120 real and experimental injuries of this type were available for the investigation with the use of simulation by the finite-elemental analysis. A set of morphological features has been identified that make it possible to determine the direction of rotation of the gunshot projectile.

  16. Scale-dependent cyclone-anticyclone asymmetry in a forced rotating turbulence experiment

    NASA Astrophysics Data System (ADS)

    Gallet, B.; Campagne, A.; Cortet, P.-P.; Moisy, F.

    2014-03-01

    We characterize the statistical and geometrical properties of the cyclone-anticyclone asymmetry in a statistically steady forced rotating turbulence experiment. Turbulence is generated by a set of vertical flaps which continuously inject velocity fluctuations towards the center of a tank mounted on a rotating platform. We first characterize the cyclone-anticyclone asymmetry from conventional single-point vorticity statistics. We propose a phenomenological model to explain the emergence of the asymmetry in the experiment, from which we predict scaling laws for the root-mean-square velocity in good agreement with the experimental data. We further quantify the cyclone-anticyclone asymmetry using a set of third-order two-point velocity correlations. We focus on the correlations which are nonzero only if the cyclone-anticyclone symmetry is broken. They offer two advantages over single-point vorticity statistics: first, they are defined from velocity measurements only, so an accurate resolution of the Kolmogorov scale is not required; second, they provide information on the scale-dependence of the cyclone-anticyclone asymmetry. We compute these correlation functions analytically for a random distribution of independent identical vortices. These model correlations describe well the experimental ones, indicating that the cyclone-anticyclone asymmetry is dominated by the large-scale long-lived cyclones.

  17. Fabry-Perot enhanced Faraday rotation in graphene.

    PubMed

    Ubrig, Nicolas; Crassee, Iris; Levallois, Julien; Nedoliuk, Ievgeniia O; Fromm, Felix; Kaiser, Michl; Seyller, Thomas; Kuzmenko, Alexey B

    2013-10-21

    We demonstrate that giant Faraday rotation in graphene in the terahertz range due to the cyclotron resonance is further increased by constructive Fabry-Perot interference in the supporting substrate. Simultaneously, an enhanced total transmission is achieved, making this effect doubly advantageous for graphene-based magneto-optical applications. As an example, we present far-infrared spectra of epitaxial multilayer graphene grown on the C-face of 6H-SiC, where the interference fringes are spectrally resolved and a Faraday rotation up to 0.15 radians (9°) is attained. Further, we discuss and compare other ways to increase the Faraday rotation using the principle of an optical cavity.

  18. Left-sided breast cancer irradiation using rotational and fixed-field radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qi, X. Sharon, E-mail: xqi@mednet.ucla.edu; Liu, Tian X.; Liu, Arthur K.

    2014-10-01

    The 3-dimensional conformal radiotherapy (3DCRT) technique is the standard for breast cancer radiotherapy. During treatment planning, not only the coverage of the planning target volume (PTV) but also the minimization of the dose to critical structures, such as the lung, heart, and contralateral breast tissue, need to be considered. Because of the complexity and variations of patient anatomy, more advanced radiotherapy techniques are sometimes desired to better meet the planning goals. In this study, we evaluated external-beam radiation treatment techniques for left breast cancer using various delivery platforms: fixed-field including TomoDirect (TD), static intensity-modulated radiotherapy (sIMRT), and rotational radiotherapy includingmore » Elekta volumetric-modulated arc therapy (VMAT) and tomotherapy helical (TH). A total of 10 patients with left-sided breast cancer who did or did not have positive lymph nodes and were previously treated with 3DCRT/sIMRT to the entire breast were selected, their treatment was planned with Monaco VMAT, TD, and TH. Dosimetric parameters including PTV coverage, organ-at-risk (OAR) sparing, dose-volume histograms, and target minimum/maximum/mean doses were evaluated. It is found that for plans providing comparable PTV coverage, the Elekta VMAT plans were generally more inhomogeneous than the TH and TD plans. For the cases with regional node involvement, the average mean doses administered to the heart were 9.2 (± 5.2) and 8.8 (± 3.0) Gy in the VMAT and TH plans compared with 11.9 (± 6.4) and 11.8 (± 9.2) Gy for the 3DCRT and TD plans, respectively, with slightly higher doses given to the contralateral lung or breast or both. On average, the total monitor units for VMAT plans are 11.6% of those TH plans. Our studies have shown that VMAT and TH plans offer certain dosimetric advantages over fixed-field IMRT plans for advanced breast cancer requiring regional nodal treatment. However, for early-stage breast cancer fixed-field radiotherapy is potentially more beneficial in terms of OAR sparing.« less

  19. Left-sided breast cancer irradiation using rotational and fixed-field radiotherapy.

    PubMed

    Qi, X Sharon; Liu, Tian X; Liu, Arthur K; Newman, Francis; Rabinovitch, Rachel; Kavanagh, Brian; Hu, Y Angie

    2014-01-01

    The 3-dimensional conformal radiotherapy (3DCRT) technique is the standard for breast cancer radiotherapy. During treatment planning, not only the coverage of the planning target volume (PTV) but also the minimization of the dose to critical structures, such as the lung, heart, and contralateral breast tissue, need to be considered. Because of the complexity and variations of patient anatomy, more advanced radiotherapy techniques are sometimes desired to better meet the planning goals. In this study, we evaluated external-beam radiation treatment techniques for left breast cancer using various delivery platforms: fixed-field including TomoDirect (TD), static intensity-modulated radiotherapy (sIMRT), and rotational radiotherapy including Elekta volumetric-modulated arc therapy (VMAT) and tomotherapy helical (TH). A total of 10 patients with left-sided breast cancer who did or did not have positive lymph nodes and were previously treated with 3DCRT/sIMRT to the entire breast were selected, their treatment was planned with Monaco VMAT, TD, and TH. Dosimetric parameters including PTV coverage, organ-at-risk (OAR) sparing, dose-volume histograms, and target minimum/maximum/mean doses were evaluated. It is found that for plans providing comparable PTV coverage, the Elekta VMAT plans were generally more inhomogeneous than the TH and TD plans. For the cases with regional node involvement, the average mean doses administered to the heart were 9.2 (± 5.2) and 8.8 (± 3.0)Gy in the VMAT and TH plans compared with 11.9 (± 6.4) and 11.8 (± 9.2)Gy for the 3DCRT and TD plans, respectively, with slightly higher doses given to the contralateral lung or breast or both. On average, the total monitor units for VMAT plans are 11.6% of those TH plans. Our studies have shown that VMAT and TH plans offer certain dosimetric advantages over fixed-field IMRT plans for advanced breast cancer requiring regional nodal treatment. However, for early-stage breast cancer fixed-field radiotherapy is potentially more beneficial in terms of OAR sparing. Copyright © 2014 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  20. Design and Development of Micro-Power Generating Device for Biomedical Applications of Lab-on-a-Disc

    PubMed Central

    Joseph, Karunan; Ibrahim, Fatimah; Cho, Jongman; Thio, Tzer Hwai Gilbert; Al-Faqheri, Wisam; Madou, Marc

    2015-01-01

    The development of micro-power generators for centrifugal microfluidic discs enhances the platform as a green point-of-care diagnostic system and eliminates the need for attaching external peripherals to the disc. In this work, we present micro-power generators that harvest energy from the disc’s rotational movement to power biomedical applications on the disc. To implement these ideas, we developed two types of micro-power generators using piezoelectric films and an electromagnetic induction system. The piezoelectric-based generator takes advantage of the film’s vibration during the disc’s rotational motion, whereas the electromagnetic induction-based generator operates on the principle of current generation in stacks of coil exposed to varying magnetic flux. We have successfully demonstrated that at the spinning speed of 800 revolutions per minute (RPM) the piezoelectric film-based generator is able to produce up to 24 microwatts using 6 sets of films and the magnetic induction-based generator is capable of producing up to 125 milliwatts using 6 stacks of coil. As a proof of concept, a custom made localized heating system was constructed to test the capability of the magnetic induction-based generator. The heating system was able to achieve a temperature of 58.62°C at 2200 RPM. This development of lab-on-a-disc micro power generators preserves the portability standards and enhances the future biomedical applications of centrifugal microfluidic platforms. PMID:26422249

  1. A multi-reference filtered-x-Newton narrowband algorithm for active isolation of vibration and experimental investigations

    NASA Astrophysics Data System (ADS)

    Wang, Chun-yu; He, Lin; Li, Yan; Shuai, Chang-geng

    2018-01-01

    In engineering applications, ship machinery vibration may be induced by multiple rotational machines sharing a common vibration isolation platform and operating at the same time, and multiple sinusoidal components may be excited. These components may be located at frequencies with large differences or at very close frequencies. A multi-reference filtered-x Newton narrowband (MRFx-Newton) algorithm is proposed to control these multiple sinusoidal components in an MIMO (multiple input and multiple output) system, especially for those located at very close frequencies. The proposed MRFx-Newton algorithm can decouple and suppress multiple sinusoidal components located in the same narrow frequency band even though such components cannot be separated from each other by a narrowband-pass filter. Like the Fx-Newton algorithm, good real-time performance is also achieved by the faster convergence speed brought by the 2nd-order inverse secondary-path filter in the time domain. Experiments are also conducted to verify the feasibility and test the performance of the proposed algorithm installed in an active-passive vibration isolation system in suppressing the vibration excited by an artificial source and air compressor/s. The results show that the proposed algorithm not only has comparable convergence rate as the Fx-Newton algorithm but also has better real-time performance and robustness than the Fx-Newton algorithm in active control of the vibration induced by multiple sound sources/rotational machines working on a shared platform.

  2. Insect-controlled Robot: A Mobile Robot Platform to Evaluate the Odor-tracking Capability of an Insect.

    PubMed

    Ando, Noriyasu; Emoto, Shuhei; Kanzaki, Ryohei

    2016-12-19

    Robotic odor source localization has been a challenging area and one to which biological knowledge has been expected to contribute, as finding odor sources is an essential task for organism survival. Insects are well-studied organisms with regard to odor tracking, and their behavioral strategies have been applied to mobile robots for evaluation. This "bottom-up" approach is a fundamental way to develop biomimetic robots; however, the biological analyses and the modeling of behavioral mechanisms are still ongoing. Therefore, it is still unknown how such a biological system actually works as the controller of a robotic platform. To answer this question, we have developed an insect-controlled robot in which a male adult silkmoth (Bombyx mori) drives a robot car in response to odor stimuli; this can be regarded as a prototype of a future insect-mimetic robot. In the cockpit of the robot, a tethered silkmoth walked on an air-supported ball and an optical sensor measured the ball rotations. These rotations were translated into the movement of the two-wheeled robot. The advantage of this "hybrid" approach is that experimenters can manipulate any parameter of the robot, which enables the evaluation of the odor-tracking capability of insects and provides useful suggestions for robotic odor-tracking. Furthermore, these manipulations are non-invasive ways to alter the sensory-motor relationship of a pilot insect and will be a useful technique for understanding adaptive behaviors.

  3. Orientation and Rotational Motions of Single Molecules by Polarized Total Internal Reflection Fluorescence Microscopy (polTIRFM)

    PubMed Central

    Beausang, John F.; Sun, Yujie; Quinlan, Margot E.; Forkey, Joseph N.; Goldman, Yale E.

    2013-01-01

    In this article, we describe methods to detect the spatial orientation and rotational dynamics of single molecules using polarized total internal reflection fluorescence microscopy (polTIRFM). polTIRFM determines the three-dimensional angular orientation and the extent of wobble of a fluorescent probe bound to the macromolecule of interest. We discuss single-molecule versus ensemble measurements, as well as single-molecule techniques for orientation and rotation, and fluorescent probes for orientation studies. Using calmodulin (CaM) as an example of a target protein, we describe a method for labeling CaM with bifunctional rhodamine (BR). We also describe the physical principles and experimental setup of polTIRFM. We conclude with a brief introduction to assays using polTIRFM to assess the interaction of actin and myosin. PMID:22550303

  4. Kinematic comparison between mobile-bearing and fixed-bearing inserts in NexGen legacy posterior stabilized flex total knee arthroplasty.

    PubMed

    Shi, Kenrin; Hayashida, Kenji; Umeda, Naoya; Yamamoto, Kengo; Kawai, Hideo

    2008-02-01

    Femoral component rollback and tibial rotation were evaluated using lateral radiographs taken during passive knee flexion under fluoroscopy in NexGen Legacy Posterior Stabilized Flex (Zimmer, Warsaw, Ind) total knee arthroplasties (TKAs; 30 with mobile insert and 26 with fixed insert). Measured maximal flexion angle demonstrated no significant differences. Femoral component rollback was observed predominantly in TKAs with fixed insert in more than 45 degrees flexion and correlated with maximal flexion angle in each group. Tibial internal rotation was more significant in TKAs with mobile insert in maximal flexion. However, tibial internal rotation from 90 degrees to maximal flexion, which demonstrated correlation with maximal flexion angle in each group, did not show significant difference. The kinematic differences between 2 inserts seemed to have little relevance to the maximal flexion angle.

  5. TU-CD-304-01: FEATURED PRESENTATION and BEST IN PHYSICS (THERAPY): Trajectory Modulated Arc Therapy: Development of Novel Arc Delivery Techniques Integrating Dynamic Table Motion for Extended Volume Treatments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chin, E; Hoppe, R; Million, L

    2015-06-15

    Purpose: Integration of coordinated robotic table motion with inversely-planned arc delivery has the potential to resolve table-top delivery limitations of large-field treatments such as Total Body Irradiation (TBI), Total Lymphoid Irradiation (TLI), and Cranial-Spinal Irradiation (CSI). We formulate the foundation for Trajectory Modulated Arc Therapy (TMAT), and using Varian Developer Mode capabilities, experimentally investigate its practical implementation for such techniques. Methods: A MATLAB algorithm was developed for inverse planning optimization of the table motion, MLC positions, and gantry motion under extended-SSD geometry. To maximize the effective field size, delivery trajectories for TMAT TBI were formed with the table rotated atmore » 270° IEC and dropped vertically to 152.5cm SSD. Preliminary testing of algorithm parameters was done through retrospective planning analysis. Robotic delivery was programmed using custom XML scripting on the TrueBeam Developer Mode platform. Final dose was calculated using the Eclipse AAA algorithm. Initial verification of delivery accuracy was measured using OSLDs on a solid water phantom of varying thickness. Results: A comparison of DVH curves demonstrated that dynamic couch motion irradiation was sufficiently approximated by static control points spaced in intervals of less than 2cm. Optimized MLC motion decreased the average lung dose to 68.5% of the prescription dose. The programmed irradiation integrating coordinated table motion was deliverable on a TrueBeam STx linac in 6.7 min. With the couch translating under an open 10cmx20cm field angled at 10°, OSLD measurements along the midline of a solid water phantom at depths of 3, 5, and 9cm were within 3% of the TPS AAA algorithm with an average deviation of 1.2%. Conclusion: A treatment planning and delivery system for Trajectory Modulated Arc Therapy of extended volumes has been established and experimentally demonstrated for TBI. Extension to other treatment techniques such as TLI and CSI is readily achievable through the developed platform. Grant Funding by Varian Medical Systems.« less

  6. Mobile remote manipulator vehicle system

    NASA Technical Reports Server (NTRS)

    Bush, Harold G. (Inventor); Mikulas, Martin M., Jr. (Inventor); Wallsom, Richard E. (Inventor); Jensen, J. Kermit (Inventor)

    1987-01-01

    A mobile remote manipulator system is disclosed for assembly, repair and logistics transport on, around and about a space station square bay truss structure. The vehicle is supported by a square track arrangement supported by guide pins integral with the space station truss structure and located at each truss node. Propulsion is provided by a central push-pull drive mechanism that extends out from the vehicle one full structural bay over the truss and locks drive rods into the guide pins. The draw bar is now retracted and the mobile remote manipulator system is pulled onto the next adjacent structural bay. Thus, translation of the vehicle is inchworm style. The drive bar can be locked onto two guide pins while the extendable draw bar is within the vehicle and then push the vehicle away one bay providing bidirectional push-pull drive. The track switches allow the vehicle to travel in two orthogonal directions over the truss structure which coupled with the bidirectional drive, allow movement in four directions on one plane. The top layer of this trilayered vehicle is a logistics platform. This platform is capable of 369 degees of rotation and will have two astronaut foot restraint platforms and a space crane integral.

  7. Metallo-Graphene Nanocomposite Electrocatalytic Platform for the Determination of Toxic Metal Ions

    PubMed Central

    Willemse, Chandre M.; Tlhomelang, Khotso; Jahed, Nazeem; Baker, Priscilla G.; Iwuoha, Emmanuel I.

    2011-01-01

    A Nafion-Graphene (Nafion-G) nanocomposite solution in combination with an in situ plated mercury film electrode was used as a highly sensitive electrochemical platform for the determination of Zn2+, Cd2+, Pb2+ and Cu2+ in 0.1 M acetate buffer (pH 4.6) by square-wave anodic stripping voltammetry (SWASV). Various operational parameters such as deposition potential, deposition time and electrode rotation speed were optimized. The Nafion-G nanocomposite sensing platform exhibited improved sensitivity for metal ion detection, in addition to well defined, reproducible and sharp stripping signals. The linear calibration curves ranged from 1 μg L−1 to 7 μg L−1 for individual analysis. The detection limits (3σ blank/slope) obtained were 0.07 μg L−1 for Pb2+, Zn2+ and Cu2+ and 0.08 μg L−1 for Cd2+ at a deposition time of 120 s. For practical applications recovery studies was done by spiking test samples with known concentrations and comparing the results with inductively coupled plasma mass spectrometry (ICP-MS) analyses. This was followed by real sample analysis. PMID:22163831

  8. Structure and tectonic evolution of the NE segment of the Polish-Ukrainian Carpathians during the Late Cenozoic: subsurface cross-sections and palinspastic models

    NASA Astrophysics Data System (ADS)

    Kuśmierek, Jan; Baran, Urszula

    2016-08-01

    The discrepant arrangement of the Carpathian nappes and syntectonic deposits of the Carpathian Foredeep reveals the oroclinal migration of the subduction direction of the platform margin during the Late Cenozoic. Formation of the nappes was induced by their detachment from disintegrated segments of the European Platform; the segments were shortened as a result of their vertical rotation in zones of compressional sutures. It finds expression in local occurrence of the backward vergence of folding against the generally forward vergence toward the Carpathian Foredeep. The precompressional configuration of sedimentation areas of particular nappes was reconstructed with application of the palinspastic method, on the basis of the hitherto undervalued model which emphasizes the influence of the subduction and differentiated morphology of the platform basement on the tectonic evolution of the fold and thrust belt. Superposition of the palaeogeographic representations and the present geometry of the orogen allows understanding of the impact of the magnitudes of tectonic displacements on the differentiation of the geological structure in the NE segment of the Carpathians. The differentiation has inspired different views of Polish and Ukrainian geologists on structural classification and evolution of the frontal thrusts.

  9. Platform C South Arrival

    NASA Image and Video Library

    2016-08-04

    A heavy load transport truck from Tillett Heavy Hauling in Titusville, Florida, arrives at the Vehicle Assembly Building (VAB) at NASA’s Kennedy Space Center in Florida, carrying a section of the first half of the C-level work platforms, C South, for the agency’s Space Launch System (SLS) rocket. The platform is being lifted and transferred onto support stands in the VAB staging area in the west parking lot. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to VAB High Bay 3 to support processing of the SLS and Orion spacecraft. A total of 10 levels of new platforms, 20 platform halves altogether, will surround the SLS rocket and Orion spacecraft and provide access for testing and processing.

  10. SU-F-BRE-05: Development and Evaluation of a Real-Time Robotic 6D Quality Assurance Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Belcher, AH; Liu, X; Grelewicz, Z

    Purpose: A 6 degree-of-freedom robotic phantom capable of reproducing dynamic tumor motion in 6D was designed to more effectively match solid tumor movements throughout pre-treatment scanning and radiation therapy. With the abundance of optical and x-ray 6D real-time tumor tracking methodologies clinically available, and the substantial dosimetric consequences of failing to consider tumor rotation as well as translation, this work presents the development and evaluation of a 6D instrument with the facility to improve quality assurance. Methods: An in-house designed and built 6D robotic motion phantom was constructed following the so-called Stewart-Gough parallel kinematics platform archetype. The device was thenmore » controlled using an inverse kinematics formulation, and precise movements in all six degrees of freedom (X, Y, Z, pitch, roll, and yaw) as well as previously obtained cranial motion, were effectively executed. The robotic phantom movements were verified using a 15 fps 6D infrared marker tracking system (Polaris, NDI), and quantitatively compared to the input trajectory. Thus, the accuracy and repeatability of 6D motion was investigated and the phantom performance was characterized. Results: Evaluation of the 6D platform demonstrated translational RMSE values of 0.196 mm, 0.260 mm, and 0.101 mm over 20 mm in X and Y and 10 mm in Z, respectively, and rotational RMSE values of 0.068 degrees, 0.0611 degrees, and 0.095 degrees over 10 degrees of pitch, roll, and yaw, respectively. The robotic stage also effectively performed controlled 6D motions, as well as reproduced cranial trajectories over 15 minutes, with a maximal RMSE of 0.044 mm translationally and 0.036 degrees rotationally. Conclusion: This 6D robotic phantom has proven to be accurate under clinical standards and capable of reproducing tumor motion in 6D. Consequently, such a robotics device has the potential to serve as a more effective system for IGRT QA that involves both translational and rotational dimensions. Research was partially funded by NIH Grant T32 EB002103-21 from NIBIB. Contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIBIB or NIH.« less

  11. Nitrogen and phosphorus effluent loads from a paddy-field district adopting collective crop rotation.

    PubMed

    Hama, T; Aoki, T; Osuga, K; Sugiyama, S; Iwasaki, D

    2012-01-01

    Japanese paddy rice systems commonly adopt the rotation of vegetables, wheat and soybeans with paddy rice. Crop rotation may, however, increase the nutrient load in effluent discharged from the district because more fertilizer is applied to the rotation crops than is applied to paddy crops. We investigated a paddy-field district subject to collective crop rotation and quantified the annual nutrient load of effluent from the district in three consecutive years. The total annual exports of nitrogen and phosphorus over the investigation period ranged from 30.3 to 40.6 kg N ha(-1) and 2.62 to 3.13 kg P ha(-1). The results suggest that rotation cropping increases the effluent nutrient load because applied fertilizer is converted to nitrate, and surface runoff is increased due to the absence of shuttering boards at the field outlets.

  12. Spacecraft platform cost estimating relationships

    NASA Technical Reports Server (NTRS)

    Gruhl, W. M.

    1972-01-01

    The three main cost areas of unmanned satellite development are discussed. The areas are identified as: (1) the spacecraft platform (SCP), (2) the payload or experiments, and (3) the postlaunch ground equipment and operations. The SCP normally accounts for over half of the total project cost and accurate estimates of SCP costs are required early in project planning as a basis for determining total project budget requirements. The development of single formula SCP cost estimating relationships (CER) from readily available data by statistical linear regression analysis is described. The advantages of single formula CER are presented.

  13. Nimbus-7 Earth radiation budget calibration history. Part 1: The solar channels

    NASA Technical Reports Server (NTRS)

    Kyle, H. Lee; Hoyt, Douglas V.; Hickey, John R.; Maschhoff, Robert H.; Vallette, Brenda J.

    1993-01-01

    The Earth Radiation Budget (ERB) experiment on the Nimbus-7 satellite measured the total solar irradiance plus broadband spectral components on a nearly daily basis from 16 Nov. 1978, until 16 June 1992. Months of additional observations were taken in late 1992 and in 1993. The emphasis is on the electrically self calibrating cavity radiometer, channel 10c, which recorded accurate total solar irradiance measurements over the whole period. The spectral channels did not have inflight calibration adjustment capabilities. These channels can, with some additional corrections, be used for short-term studies (one or two solar rotations - 27 to 60 days), but not for long-term trend analysis. For channel 10c, changing radiometer pointing, the zero offsets, the stability of the gain, the temperature sensitivity, and the influences of other platform instruments are all examined and their effects on the measurements considered. Only the question of relative accuracy (not absolute) is examined. The final channel 10c product is also compared with solar measurements made by independent experiments on other satellites. The Nimbus experiment showed that the mean solar energy was about 0.1 percent (1.4 W/sqm) higher in the excited Sun years of 1979 and 1991 than in the quiet Sun years of 1985 and 1986. The error analysis indicated that the measured long-term trends may be as accurate as +/- 0.005 percent. The worse-case error estimate is +/- 0.03 percent.

  14. Finite Element Analysis of Influence of Axial Position of Center of Rotation of a Cervical Total Disc Replacement on Biomechanical Parameters: Simulated 2-Level Replacement Based on a Validated Model.

    PubMed

    Li, Yang; Zhang, Zhenjun; Liao, Zhenhua; Mo, Zhongjun; Liu, Weiqiang

    2017-10-01

    Finite element models have been widely used to predict biomechanical parameters of the cervical spine. Previous studies investigated the influence of position of rotational centers of prostheses on cervical biomechanical parameters after 1-level total disc replacement. The purpose of this study was to explore the effects of axial position of rotational centers of prostheses on cervical biomechanics after 2-level total disc replacement. A validated finite element model of C3-C7 segments and 2 prostheses, including the rotational center located at the superior endplate (SE) and inferior endplate (IE), was developed. Four total disc replacement models were used: 1) IE inserted at C4-C5 disc space and IE inserted at C5-C6 disc space (IE-IE), 2) IE-SE, 3) SE-IE, and 4) SE-SE. All models were subjected to displacement control combined with a 50 N follower load to simulate flexion and extension motions in the sagittal plane. For each case, biomechanical parameters, including predicted moments, range of rotation at each level, facet joint stress, and von Mises stress on the ultra-high-molecular-weight polyethylene core of the prostheses, were calculated. The SE-IE model resulted in significantly lower stress at the cartilage level during extension and at the ultra-high-molecular-weight polyethylene cores when compared with the SE-SE construct and did not generate hypermotion at the C4-C5 level compared with the IE-SE and IE-IE constructs. Based on the present analysis, the SE-IE construct is recommended for treating cervical disease at the C4-C6 level. This study may provide a useful model to inform clinical operations. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Three-dimensional knee joint kinematics during golf swing and stationary cycling after total knee arthroplasty.

    PubMed

    Hamai, Satoshi; Miura, Hiromasa; Higaki, Hidehiko; Shimoto, Takeshi; Matsuda, Shuichi; Okazaki, Ken; Iwamoto, Yukihide

    2008-12-01

    The expectation of returning to sports activities after total knee arthroplasty (TKA) has become more important to patients than ever. To our knowledge, no studies have been published evaluating the three-dimensional knee joint kinematics during sports activity after TKA. Continuous X-ray images of the golf swing and stationary cycling were taken using a large flat panel detector for four and eight post-arthroplasty knees, respectively. The implant flexion and axial rotation angles were determined using a radiographic-based, image-matching technique. Both the golf swing from the set-up position to the top of the backswing, and the stationary cycling from the top position of the crank to the bottom position of the crank, produced progressive axial rotational motions (p = 0.73). However, the golf swing from the top of the backswing to the end of the follow-through produced significantly larger magnitudes of rotational motions in comparison to stationary cycling (p < 0.01). Excessive internal-external rotations generated from the top of the backswing to the end of the follow-through could contribute to accelerated polyethylene wear. However, gradual rotational movements were consistently demonstrated during the stationary cycling. Therefore, stationary cycling is recommended rather than playing golf for patients following a TKA who wish to remain physically active.

  16. Mobile-bearing total knee arthroplasty: a full traumatic rotation of 180°.

    PubMed

    Sudanese, Alessandra; Castiello, Emanuela; Affatato, Saverio

    2013-06-25

    From February 2008 to September 2012 we implanted 204 mobile-bearing knee prostheses in 192 patients. All the prostheses were cemented (both femoral and tibial components), and the patella was not replaced. Only one early complication of the implants (1/204 = 0.004%) occurred after a traumatic event as a full 180° rotation of the mobile-bearing polyethylene insert. A 78-year-old woman presented with swelling and severe pain at her right knee. This traumatic event was the only case among our mobile-bearing insert patients. 
The failed polyethylene inserts were retrieved and studied using a scanning electron microscope (SEM, ZEISS EVO 50 EP, Cambridge, UK) operating at 20 kV. 
Scratching and pitting were found on the UHMWPE insert perpendicular to the machining tracks for the concave surface. SEM micrographs of the insert showed burnishing on the concave surfaces and longitudinal scratches were clearly detectable and well-marked on the analyzed surfaces. 
A traumatic, fully rotating, polyethylene insert is rare and our case is the first report describing a traumatic event with a complete 180 degree rotation mobile-bearing in a total knee prosthesis. 
In the literature few reports discuss clinical outcomes after total knee arthroplasty in patients with Parkinson's disease and they cite mixed results. However, some authors suggest that posterior-stabilized and cruciate-retaining TKA should work well while others prefer cruciate-retaining, condylar constrained kinetics, or hinged devices. Although we did not implant a posterior-stabilized mobile-bearing total knee prosthesis or a constrained prosthesis, we obtained good clinical and radiological results at the 2-year followup.

  17. Impact of a postgraduate six-month rotation in palliative care on knowledge and attitudes of junior residents.

    PubMed

    Duong, Phuc H; Zulian, Gilbert B

    2006-07-01

    Fifty junior residents completed a six-month training period. An anonymous postal questionnaire was sent to collect the residents' opinions on improvements in their knowledge, perception of priorities and usefulness of training. Responses were rated from 5 (a great deal) to 1 (not at all improved). A total of 33 (66%) questionnaires were returned. A mean score of 4.48 was obtained on general improvement of knowledge, 4.91 +/- 0.29 on pain control, 4.17 +/- 0.58 on neurological symptoms, 4.09 +/- 0.77 on psychological symptoms, 4.64 +/- 0.60 on communication skills and 4.4 +/- 0.91 on physician attitudes. Some 58% of residents began the training with apprehension, 85% outlined their priorities and 76% reached these objectives. A total of 70% were fully satisfied with the tuition and support received and 98% recommended such clinical rotation. Data suggest that a six-month rotation in palliative care results in high levels of perception of improvement in knowledge and satisfaction. Exposure to palliative care patients during clinical rotations in specialized centres must be encouraged.

  18. Testing Modified Newtonian Dynamics with Low Surface Brightness Galaxies: Rotation Curve FITS

    NASA Astrophysics Data System (ADS)

    de Blok, W. J. G.; McGaugh, S. S.

    1998-11-01

    We present modified Newtonian dynamics (MOND) fits to 15 rotation curves of low surface brightness (LSB) galaxies. Good fits are readily found, although for a few galaxies minor adjustments to the inclination are needed. Reasonable values for the stellar mass-to-light ratios are found, as well as an approximately constant value for the total (gas and stars) mass-to-light ratio. We show that the LSB galaxies investigated here lie on the one, unique Tully-Fisher relation, as predicted by MOND. The scatter on the Tully-Fisher relation can be completely explained by the observed scatter in the total mass-to-light ratio. We address the question of whether MOND can fit any arbitrary rotation curve by constructing a plausible fake model galaxy. While MOND is unable to fit this hypothetical galaxy, a normal dark-halo fit is readily found, showing that dark matter fits are much less selective in producing fits. The good fits to rotation curves of LSB galaxies support MOND, especially because these are galaxies with large mass discrepancies deep in the MOND regime.

  19. Real-time MRI-guided hyperthermia treatment using a fast adaptive algorithm

    NASA Astrophysics Data System (ADS)

    Stakhursky, Vadim L.; Arabe, Omar; Cheng, Kung-Shan; MacFall, James; Maccarini, Paolo; Craciunescu, Oana; Dewhirst, Mark; Stauffer, Paul; Das, Shiva K.

    2009-04-01

    Magnetic resonance (MR) imaging is promising for monitoring and guiding hyperthermia treatments. The goal of this work is to investigate the stability of an algorithm for online MR thermal image guided steering and focusing of heat into the target volume. The control platform comprised a four-antenna mini-annular phased array (MAPA) applicator operating at 140 MHz (used for extremity sarcoma heating) and a GE Signa Excite 1.5 T MR system, both of which were driven by a control workstation. MR proton resonance frequency shift images acquired during heating were used to iteratively update a model of the heated object, starting with an initial finite element computed model estimate. At each iterative step, the current model was used to compute a focusing vector, which was then used to drive the next iteration, until convergence. Perturbation of the driving vector was used to prevent the process from stalling away from the desired focus. Experimental validation of the performance of the automatic treatment platform was conducted with two cylindrical phantom studies, one homogeneous and one muscle equivalent with tumor tissue (conductivity 50% higher) inserted, with initial focal spots being intentionally rotated 90° and 50° away from the desired focus, mimicking initial setup errors in applicator rotation. The integrated MR-HT treatment platform steered the focus of heating into the desired target volume in two quite different phantom tissue loads which model expected patient treatment configurations. For the homogeneous phantom test where the target was intentionally offset by 90° rotation of the applicator, convergence to the proper phase focus in the target occurred after 16 iterations of the algorithm. For the more realistic test with a muscle equivalent phantom with tumor inserted with 50° applicator displacement, only two iterations were necessary to steer the focus into the tumor target. Convergence improved the heating efficacy (the ratio of integral temperature in the tumor to integral temperature in normal tissue) by up to six-fold, compared to the first iteration. The integrated MR-HT treatment algorithm successfully steered the focus of heating into the desired target volume for both the simple homogeneous and the more challenging muscle equivalent phantom with tumor insert models of human extremity sarcomas after 16 and 2 iterations, correspondingly. The adaptive method for MR thermal image guided focal steering shows promise when tested in phantom experiments on a four-antenna phased array applicator.

  20. Patch-Augmented Rotator Cuff Repair and Superior Capsule Reconstruction

    PubMed Central

    Petri, M.; Greenspoon, J.A.; Moulton, S.G.; Millett, P.J.

    2016-01-01

    Background: Massive rotator cuff tears in active patients with minimal glenohumeral arthritis remain a particular challenge for the treating surgeon. Methods: A selective literature search was performed and personal surgical experiences are reported. Results: For patients with irreparable rotator cuff tears, a reverse shoulder arthroplasty or a tendon transfer are often performed. However, both procedures have rather high complication rates and debatable long-term results, particularly in younger patients. Therefore, patch-augmented rotator cuff repair or superior capsule reconstruction (SCR) have been recently developed as arthroscopically applicable treatment options, with promising biomechanical and early clinical results. Conclusion: For younger patients with irreparable rotator cuff tears wishing to avoid tendon transfers or reverse total shoulder arthroplasty, both patch-augmentation and SCR represent treatment options that may delay the need for more invasive surgery. PMID:27708733

  1. [Relationship of job stress with job burnout and quality of work life in workers for offshore oil platforms].

    PubMed

    Zhang, Y; Liu, X L; Wei, T D; Lan, Y J

    2017-03-20

    Objective: To evaluate the current status of job burnout and qual ity of work life (QWL) in workers for offshore oil platforms, and to analyze the relationship of job stress with job burnout and QWL and the direct and indirect effects of job stress on QWL. Methods: Cluster random sampling was used to select 382 work-ers for 8 oil platforms of China National Offshore Oil Corporation in October 2015. A self - designed questionnaire was used to collect the individual characteristics of subjects. The Quality of Work Life Scale (QWL7 - 32) , Occupa-tional Stress Inventory - Revised Edition (OSI - R) , and Maslach Burnout Inventory - General Survey (MBI - GS) were used to investigate the QWL, job stress, and job burnout of subjects. Results: Among all the workers for offshore oil platforms, 87.2% had mild job burnout. The total QWL score was 116.01 ± 16.73; 8.3% of the workers had poor QWL, and 68.5% had moderate QWL. QWL was reduced with heavier task, vaguer task, and increasing mental stress and physical stress ( P <0.05) , and increased with more social support ( P <0.05) . Job stress had di-rect and indirect effects on QWL; stress reaction had the most effect on QWL (total effect size - 0.509) , followed by social support (total effect size 0.444) . Conclusion: Most workers for offshore oil platforms have mild job burn-out and moderate QWL. Job stress is associated with job burnout and QWL, and stress reaction and social support have relatively high influence on QWL.

  2. Simplified modelling and analysis of a rotating Euler-Bernoulli beam with a single cracked edge

    NASA Astrophysics Data System (ADS)

    Yashar, Ahmed; Ferguson, Neil; Ghandchi-Tehrani, Maryam

    2018-04-01

    The natural frequencies and mode shapes of the flapwise and chordwise vibrations of a rotating cracked Euler-Bernoulli beam are investigated using a simplified method. This approach is based on obtaining the lateral deflection of the cracked rotating beam by subtracting the potential energy of a rotating massless spring, which represents the crack, from the total potential energy of the intact rotating beam. With this new method, it is assumed that the admissible function which satisfies the geometric boundary conditions of an intact beam is valid even in the presence of a crack. Furthermore, the centrifugal stiffness due to rotation is considered as an additional stiffness, which is obtained from the rotational speed and the geometry of the beam. Finally, the Rayleigh-Ritz method is utilised to solve the eigenvalue problem. The validity of the results is confirmed at different rotational speeds, crack depth and location by comparison with solid and beam finite element model simulations. Furthermore, the mode shapes are compared with those obtained from finite element models using a Modal Assurance Criterion (MAC).

  3. Uncommon Indications for Reverse Total Shoulder Arthroplasty

    PubMed Central

    Hyun, Yoon Suk; Huri, Gazi; Garbis, Nickolas G.

    2013-01-01

    Total shoulder arthroplasty and shoulder hemiarthroplasty have been the traditional method for treating a variety of shoulder conditions, including arthritis, cuff tear arthropathy, and some fracture types. However, these procedures did not provide consistently good results for patients with torn rotator cuffs. The development of the reverse prosthesis by Grammont in the late 20th century revolutionized the treatment of the rotator-cuff-deficient shoulder with arthritis. The main indication for the reverse prosthesis remains the patient with cuff tear arthropathy who has pain and loss of motion. Because the reverse total shoulder arthroplasty produced such good results in these patients, the indications for the reverse prosthesis have expanded to include other shoulder conditions that have previously been difficult to treat successfully and predictably. This review discusses and critically reviews these newer indications for the reverse total shoulder arthroplasty. PMID:24340143

  4. Comparison of ultrasonographic findings of the rotator cuff between diabetic and nondiabetic patients with chronic shoulder pain: a retrospective study.

    PubMed

    Kang, Jiunn-Horng; Tseng, Sung-Hui; Jaw, Fu-Shan; Lai, Chien-Hung; Chen, Hung-Chou; Chen, Shih-Ching

    2010-11-01

    It is still unclear whether diabetic mellitus (DM) is associated with rotator cuff lesions. The object of this retrospective study was to compare the ultrasonographic (US) findings of rotator cuffs in diabetic patients with those of nondiabetic patients with chronic shoulder pain. In total, 419 patients (80 diabetic, 339 nondiabetic) who had chronic shoulder pain and had been referred to receive US examination between January 2005 and January 2008 in a medical center were included in this study. The US findings of rotator cuff lesions were classified into two main categories: rotator cuff tears (RCTs) and calcifying tendinopathy (CT). In total, 114 (25.2%) shoulders with CT of the rotator cuff and 160 (35.3%), 15 (3.3%) and 5 (1.1%) shoulders with supraspinatus, infraspinatus and subscapularis tears, respectively, were noted. No difference in the ratio of tears of RCTs was found on US examinations between two groups. The crude odds ratio (OR) for CT of diabetic patients was 1.85 (p = 0.014); however, the adjusted OR for CT in diabetic patients became insignificant after controlling for the other variables (OR = 1.59, p = 0.08). To our knowledge, this is the first study to explore US findings among diabetic and nondiabetic patients with chronic shoulder pain. Further study is advised to confirm our findings. Copyright © 2010 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Absolute NMR shielding scales and nuclear spin–rotation constants in {sup 175}LuX and {sup 197}AuX (X = {sup 19}F, {sup 35}Cl, {sup 79}Br and {sup 127}I)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Demissie, Taye B., E-mail: taye.b.demissie@uit.no; Komorovsky, Stanislav; Repisky, Michal

    2015-10-28

    We present nuclear spin–rotation constants, absolute nuclear magnetic resonance (NMR) shielding constants, and shielding spans of all the nuclei in {sup 175}LuX and {sup 197}AuX (X = {sup 19}F, {sup 35}Cl, {sup 79}Br, {sup 127}I), calculated using coupled-cluster singles-and-doubles with a perturbative triples (CCSD(T)) correction theory, four-component relativistic density functional theory (relativistic DFT), and non-relativistic DFT. The total nuclear spin–rotation constants determined by adding the relativistic corrections obtained from DFT calculations to the CCSD(T) values are in general in agreement with available experimental data, indicating that the computational approach followed in this study allows us to predict reliable results formore » the unknown spin–rotation constants in these molecules. The total NMR absolute shielding constants are determined for all the nuclei following the same approach as that applied for the nuclear spin–rotation constants. In most of the molecules, relativistic effects significantly change the computed shielding constants, demonstrating that straightforward application of the non-relativistic formula relating the electronic contribution to the nuclear spin–rotation constants and the paramagnetic contribution to the shielding constants does not yield correct results. We also analyze the origin of the unusually large absolute shielding constant and its relativistic correction of gold in AuF compared to the other gold monohalides.« less

  6. Patient-oriented Functional Results of Total Femoral Endoprosthetic Reconstruction Following Oncologic Resection

    PubMed Central

    Jones, Kevin B.; Griffin, Anthony M.; Chandrasekar, Coonoor R.; Biau, David; Babinet, Antoine; Deheshi, Benjamin; Bell, Robert S.; Grimer, Robert J.; Wunder, Jay S.; Ferguson, Peter C.

    2011-01-01

    Background and Objectives Functional outcomes following oncologic total femoral endoprosthetic reconstruction (TFR) are lacking. We compared patient-oriented functional results of TFRs to proximal femur and distal femur reconstructions (PFR and DFR). We also compared function and complications with regard to knee and hip componentry. Methods 54 TFR patients were identified from 3 institutional prospective databases. 41 had fixed- and 13 had rotating-hinge knees, 37 hemiarthroplasty and 17 total hip arthroplasty componentry. Toronto Extremity Salvage Scores (TESS) for n=27 were compared between groups and to cohorts of PFR (n=31) and DFR (n=85) patients using the Mann-Whitney U test. Results Follow-up averaged 4 years. Mechanical complications included 5 hip dislocations and 1 femoral malrotation. Four dislocations were in fixed-hinge implants, all in those lacking abductor reattachment. TESS averaged 69.3±17.8, statistically decreased from DFR (p=0.002) and PFR patients (p=0.036). No significant differences were detected between patients in the fixed-hinge (n=18) and rotating-hinge (n=9) groups (p = 0.944), or total hip (n=8) and hemiarthroplasty (n=19) groups (p=0.633). Conclusions TFR is reserved for extreme cases of limb salvage, portending a poor prognosis overall. Function reflects additive impairments from PFR and DFR. TFR outcomes differ little with rotating- or fixed-hinge, total hip or hemiarthroplasty implants. PMID:21695701

  7. Modular Multi-Function Multi-Band Airborne Radio System (MFBARS). Volume II. Detailed Report.

    DTIC Science & Technology

    1981-06-01

    Three Platforms in a Field of Hyperbolic LOP’s.......................... 187 76 Comparison, MFBARS Versus Baseline .......... 190 77 Program Flow Chart...configure, from a set of common modules, a given total CNI capability on specific platforms for a given mission " the ability to take advantage of...X Comm/Nav GPS L-Band; Spread Spectrum Nay X X SEEK TALK UHF Spread; Spectrum Comm X X SINCGARS VHF; Freq. Hop Comm (some platforms ) AFSATCOM UHF

  8. ACUTE CHANGES IN PASSIVE GLENOHUMERAL ROTATION FOLLOWING TENNIS PLAY EXPOSURE IN ELITE FEMALE PLAYERS

    PubMed Central

    Kibler, W. Ben; Myers, Natalie L.; Smith, Belinda J.

    2016-01-01

    Background Alterations in glenohumeral (GH) rotation especially internal rotation and total range of motion have been associated with altered GH kinematics and susceptibility to injury. Researchers have evaluated long-term change in baseball and tennis players, and short-term changes in baseball players. However, acute (short-term) changes in GH rotation have not been evaluated in tennis players. Hypotheses/Purpose The purpose of this study was to quantify short-term glenohumeral rotational changes within a group of professional women's tennis players following competitive play. It was hypothesized that there would be acute alterations in passive glenohumeral internal rotation and total range of motion following episodes of tennis play. Study Design Cohort Study Methods Passive glenohumeral external rotation (GER), glenohumeral internal rotation (GIR), and total range of motion (TROM) were evaluated in a cohort of 79 professional adult female tennis players. Measurements were taken at three different time points (TP): baseline before match play (TP1), immediately after match play (TP2), and 24-hours after baseline (TP3). Results There was a statistically significant decrease in the mean GIR from TP1 (43 ± 11 °) to TP2 (39 ± 9 °) (p=0.002) and from TP1 to TP3 (38 ± 10 °) (p=0.001). All measures were at the level of minimal detectable change (MDC) (4 °) indicating clinical significance. There was a decrease in mean TROM from TP1 (146 ± 11 °) to TP2 (142 ± 12 °) (p=0.04), which was not above MDC (7 °). Subgroup analysis showed that 47% of the players demonstrated a decrease in GIR beyond MDC, and 37% demonstrated a decrease in TROM beyond MDC. GER remained unchanged across all time points (p>0.05). Conclusion Both GIR and TROM were reduced after acute exposure to tennis play. In a large subgroup of the cohort, the changes were clinically significant and approached values previously demonstrated to be associated with increased injury risk. Given the changes in glenohumeral motion following acute exposure to tennis, evaluation of players for significant motion alterations following overhead activity and intervention strategies to minimize such alterations in these players are recommended for high level tennis players. Level of evidence Level 3 PMID:27104056

  9. Training in pathology informatics: implementation at the University of Pittsburgh.

    PubMed

    Harrison, James H; Stewart, Jimmie

    2003-08-01

    Pathology informatics is generally recognized as an important component of pathology training, but the scope, form, and goals of informatics training vary substantially between pathology residency programs. The Training and Education Committee of the Association for Pathology Informatics (API TEC) has developed a standard set of knowledge and skills objectives that are recommended for inclusion in pathology informatics training and may serve to standardize and formalize training programs in this area. The University of Pittsburgh (Pittsburgh, Pa) core rotation in pathology informatics includes most of these goals and is offered as an implementation model for pathology informatics training. The core rotation in pathology informatics is a 3-week, full-time rotation including didactic sessions and hands-on laboratories. Topics include general desktop computing and the Internet, but the primary focus of the rotation is vocabulary and concepts related to enterprise and pathology information systems, pathology practice, and research. The total contact time is 63 hours, and a total of 19 faculty and staff contribute. Pretests and posttests are given at the start and end of the rotation. Performance and course evaluation data were collected for 3 years (a total of 21 residents). The rotation implements 84% of the knowledge objectives and 94% of the skills objectives recommended by the API TEC. Residents scored an average of about 20% on the pretest and about 70% on the posttest for an average increase during the course of 50%. Posttest scores did not correlate with pretest scores or self-assessed computer skill level. The size of the pretest/posttest difference correlated negatively with the pretest scores and self-assessed computing skill level. Pretest scores were generally low regardless of whether residents were familiar with desktop computing and productivity applications, indicating that even residents who are computer "savvy" have limited knowledge of pathology informatics topics. Posttest scores showed that all residents' knowledge increased substantially during the course and that residents who were computing novices were not disadvantaged. In fact, novices tended to have higher pretest/posttest differences, indicating that the rotation effectively supported initially less knowledgeable residents in "catching up" to their peers and achieving an appropriate competency level. This rotation provides a formal training model that implements the API TEC recommendations with demonstrated success.

  10. Impact of rotation angle on crawling and non-crawling 9-month-old infants' mental rotation ability.

    PubMed

    Gerhard, Theresa M; Schwarzer, Gudrun

    2018-06-01

    The current study investigated whether 9-month-old infants' mental rotation performance was influenced by the magnitude of the angle of object rotation and their crawling ability. A total of 76 infants were tested; of these infants, 39 had been crawling for an average of 9.0 weeks. Infants were habituated to a video of a simplified Shepard-Metzler object (Shepard & Metzler, 1971), always rotating forward through a 180° angle around the horizontal axis of the object. After habituation, in two different test conditions, infants were presented with test videos of the same object rotating farther forward through a previously unseen 90° angle and with a test video of its mirror image. The two test conditions differed in the magnitude of the gap between the end of the habituation rotations and the beginning of the test rotations. The gaps were 0° and 54°. The results revealed that the mental rotation performance was influenced by the magnitude of the gaps only for the crawling infants. Their response showed significant transition from a preference for the mirror object rotations toward a preference for the familiar habituation object rotations. Thus, the results provide first evidence that it is easier for 9-month-old crawling infants to mentally rotate an object along a small angle compared with a large one. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Cultivation-Based and Molecular Assessment of Bacterial Diversity in the Rhizosheath of Wheat under Different Crop Rotations

    PubMed Central

    Tahir, Muhammad; Mirza, M. Sajjad; Hameed, Sohail; Dimitrov, Mauricio R.; Smidt, Hauke

    2015-01-01

    A field study was conducted to compare the formationand bacterial communities of rhizosheaths of wheat grown under wheat-cotton and wheat-rice rotation and to study the effects of bacterial inoculation on plant growth. Inoculation of Azospirillum sp. WS-1 and Bacillus sp. T-34 to wheat plants increased root length, root and shoot dry weight and dry weight of rhizosheathsoil when compared to non-inoculated control plants, and under both crop rotations. Comparing both crop rotations, root length, root and shoot dry weight and dry weight of soil attached with roots were higher under wheat-cotton rotation. Organic acids (citric acid, malic acid, acetic acid and oxalic acid) were detected in rhizosheaths from both rotations, with malic acid being most abundant with 24.8±2 and 21.3±1.5 μg g-1 dry soil in wheat-cotton and wheat-rice rotation, respectively. Two sugars (sucrose, glucose) were detected in wheat rhizosheath under both rotations, with highest concentrations of sucrose (4.08±0.5 μg g-1and 7.36±1.0 μg g-1) and glucose (3.12±0.5 μg g-1 and 3.01± μg g-1) being detected in rhizosheaths of non-inoculated control plants under both rotations. Diversity of rhizosheath-associated bacteria was evaluated by cultivation, as well as by 454-pyrosequencing of PCR-tagged 16S rRNA gene amplicons. A total of 14 and 12 bacterial isolates predominantly belonging to the genera Arthrobacter, Azospirillum, Bacillus, Enterobacter and Pseudomonaswere obtained from the rhizosheath of wheat grown under wheat-cotton and wheat-rice rotation, respectively. Analysis of pyrosequencing data revealed Proteobacteria, Bacteriodetes and Verrucomicrobia as the most abundant phyla in wheat-rice rotation, whereas Actinobacteria, Firmicutes, Chloroflexi, Acidobacteria, Planctomycetes and Cyanobacteria were predominant in wheat-cotton rotation. From a total of 46,971 sequences, 10.9% showed ≥97% similarity with 16S rRNA genes of 32 genera previously shown to include isolates with plant growth promoting activity (nitrogen fixation, phosphate-solubilization, IAA production). Among these, the most predominant genera were Arthrobacter, Azoarcus, Azospirillum, Bacillus, Cyanobacterium, Paenibacillus, Pseudomonas and Rhizobium. PMID:26121588

  12. The Effects of Posterior Rotator Cuff Cable Tears on Glenohumeral Biomechanics in a Cadaveric Model of the Throwing Shoulder

    PubMed Central

    Photopoulos, Christos Demetris; ElAttrache, Neal S.; Doermann, Alex; Akeda, Masaki; McGarry, Michelle H.; Lee, Thay Q.

    2017-01-01

    Objectives: The rotator cuff cable has been postulated to be the primary load bearing substructure of the superior part of the rotator cuff. Tears of the posterior rotator cable are frequently seen in overhead throwing athletes. Although the biomechanical significance of the anterior rotator cable has been well described, our current understanding of the relevance of the posterior cable is limited. The purpose of this study was to examine how partial-thickness tears and full-thickness tears of the posterior rotator cable would alter glenohumeral biomechanics and kinematics in cadaveric shoulder models. Methods: Eight fresh-frozen cadaveric shoulder specimens were prepared and tested. To simulate the sequence of glenohumeral positions during the throwing motion, specimens were mounted on a custom shoulder testing system with the humerus positioned at 90° of abduction (30° scapular upward rotation, 60° glenohumeral abduction) and tested at 30, 60, 90, and 120 degrees of external rotation. After a circumferential capsulotomy was performed, rotator cuff muscles were loaded based on physiologic cross-sectional area ratios, and testing for each specimen was performed on each the following three conditions: intact posterior cable, partial-thickness (50%) articular-sided posterior cable tear, and full-thickness posterior cable tear. Primary outcome measures tested for each condition under the various degrees of glenohumeral rotation were: 1) anterior and total glenohumeral translation after application of a 30N anterior force; 2) path of glenohumeral articulation; 3) glenohumeral joint force. Results: With a 30N anterior force at 120° of external rotation, there was a significant increase in anterior glenohumeral translation between intact and full-thickness tear specimens (7.28±2.00mm and 17.49±3.75mm, respectively; p<0.05). Similarly, total joint translation at 120° of external rotation significantly increased between intact and full-thickness tear specimens (10.37±3.18mm and 23.37±5.05mm, respectively; p<0.05). No significant differences were apparent at other degrees of rotation (30, 60, 90 degrees), or with partial-thickness tears. Changes in the path of glenohumeral articulation were likewise most evident at 120° of external rotation, with a progressively anterior, inferior, and lateral shift in articulation with sequential sectioning of the posterior cable. Lastly, with regards to alterations in glenohumeral joint force, no significant changes were seen in any of the conditions. Conclusion: In this cadaveric shoulder model of the throwing shoulder, tears of the posterior rotator cuff cable lead to altered glenohumeral biomechanics and kinematics. These changes were most profound at 120° of external rotation, suggesting the importance of an intact posterior cable as a potential stabilizer during the late-cocking phase of throwing.

  13. Two-dimensional planning can result in internal rotation of the femoral component in total knee arthroplasty.

    PubMed

    Okamoto, Shigetoshi; Mizu-uchi, Hideki; Okazaki, Ken; Hamai, Satoshi; Tashiro, Yasutaka; Nakahara, Hiroyuki; Iwamoto, Yukihide

    2016-01-01

    The first purpose of this study was to compare the reproducibility of two-dimensional (2D) and three-dimensional (3D) measurements for preoperative planning of the femoral side in total knee arthroplasty (TKA). The second purpose was to evaluate the factors affecting the differences between the 2D and 3D measurements. Two-dimensional and 3D measurements for preoperative planning of the femoral side in TKA were evaluated in 75 varus knees with osteoarthritis. The femoral valgus angle, defined as the angle between the mechanical and anatomical axes of the femur, and the clinical rotation angle and surgical rotation angle, defined by the angles between the posterior condylar line and the clinical or surgical transepicondylar axes, respectively, were analysed using 2D (radiographs and axial CT slices) and 3D (3D bone models reconstructed from CT images) measurements. For all variables, 3D measurements were more reliable and reproducible than 2D measurements. The medians and ranges of the clinical rotation angle and surgical rotation angle were 6.6° (-1.7° to 12.1°) and 2.3° (-2.5° to 8.6°) in 2D, and 7.1° (2.7° to 11.4°) and 3.0° (-2.0° to 7.5°) in 3D. Varus/valgus alteration of the CT scanning direction relative to the mechanical axis affected the difference in clinical rotation angles between 2D and 3D measurements. Significantly, smaller values of the clinical rotation angle and surgical rotation angle were obtained by 2D compared to 3D measurements, which could result in internal rotation of the femoral component even if the surgeon performs the bone cutting precisely. Regarding clinical relevance, first, this study confirmed the reliability of 3D measurements. Second, it underscored the risk of internal rotation of the femoral component when using 2D measurement, even with precise bone cutting technique. These results will help surgeons avoid malpositioning of the femoral component if 2D measurements are used for preoperative planning in TKA. Prospective comparative study, Level Ш.

  14. Effect of limb rotation on radiographic alignment in total knee arthroplasties.

    PubMed

    Radtke, Kerstin; Becher, Christoph; Noll, Yvonne; Ostermeier, Sven

    2010-04-01

    Even in a well-aligned total knee arthroplasty (TKA), limb rotation at the time of radiographic assessment will alter the measurement of alignment. This could influence the radiographic outcome of TKA. The purpose of this study was to evaluate the effect of limb rotation on radiographic alignment after TKA and to establish a re-calculation of this rotation by using existing radiographic landmarks. Synthetic femur and tibia (Sawbones), Inc. Vashon Island, WA) were used to create a TKA of the Triathlon knee prosthesis system (Stryker), Limerick, Ireland). The femoral alignment was 6.5 degrees valgus. The model was fixed in an upright stand. Five series of nine anteroposterior (AP) long leg radiographs were taken on a 30 cm x 120 cm plates in full extension with the limb rotated, in 5 degrees increments, from 20 degrees external rotation to 20 degrees internal rotation. After digitizing each radiograph (Scanner Hewlett Packard XJ 527), an observer measured the anatomic mechanical angle of the femur [AMA ( degrees )], the mechanical lateral proximal femur angle [mLPFA ( degrees )], the mechanical lateral distal femur angle [mLDFA ( degrees )], the mechanical medial proximal tibia angle [mMPTA ( degrees )] and the mechanical lateral distal tibia angle [mLDTA ( degrees )] using a digital measurement software (MediCAD, Hectec, Altfraunhofen, Germany). Besides, the observer measured the geometrical distances of the femoral component figured on the long leg radiograph. A ratio of one distance to another was measured (called femoral component distance ratio). The average radiographic anatomic alignment ranged from 6.827 degrees AMA (SD = 0.22 degrees ) in 20 degrees internal rotation to 4.627 degrees AMA (SD = 0.22 degrees ) in 20 degrees external rotation. Average mLPFA ( degrees ) ranged from 101.63 degrees (SD = 0.63) in 20 degrees internal rotation to 93.60 degrees (SD = 0.74 degrees ) in 20 degrees external rotation. Average mLDFA ( degrees ) ranged from 90.59 degrees (SD = 3.01 degrees ) in 20 degrees internal rotation to 86.76 degrees (SD = 0.36 degrees ) in 20 degrees external rotation. Average mMPTA ( degrees ) ranged from 90.35 degrees (SD = 0.81 degrees ) in 20 degrees internal rotation to 88.49 degrees (SD = 0.52 degrees ) in 20 degrees external rotation. Average mLDTA ( degrees ) ranged from 98.89 degrees (SD = 2.3 degrees ) in 20 degrees internal rotation to 90.53 degrees (SD = 3.39 degrees ) in 20 degrees external rotation. Without an application of limb rotation, the femoral component distance ratio was measured to be 0.89 (SD = 0.01), in 20 degrees internal rotation 0.63 (SD = 0.01) and in 20 degrees external rotation 1.16 (SD = 0.01). Limb rotation had a highly statistically significant effect on measured anatomic alignment and mechanical angles. A correlation between limb rotation, anatomic mechanical angle, mechanical angles measured at femur and tibia and the femoral component distance ratio was established. As the anatomic mechanical angle and the femoral component distance ratio change linearly in the range of 20 degrees internal and external limb rotation, a calculation of the femoral component distance ratio could be used to re-calculate the limb rotation at the time of radiographic assessment to evaluate the evidence of a long leg radiograph.

  15. A Highly Sensitive Porous Silicon (P-Si)-Based Human Kallikrein 2 (hK2) Immunoassay Platform toward Accurate Diagnosis of Prostate Cancer

    PubMed Central

    Lee, Sang Wook; Hosokawa, Kazuo; Kim, Soyoun; Jeong, Ok Chan; Lilja, Hans; Laurell, Thomas; Maeda, Mizuo

    2015-01-01

    Levels of total human kallikrein 2 (hK2), a protein involved the pathology of prostate cancer (PCa), could be used as a biomarker to aid in the diagnosis of this disease. In this study, we report on a porous silicon antibody immunoassay platform for the detection of serum levels of total hK2. The surface of porous silicon has a 3-dimensional macro- and nanoporous structure, which offers a large binding capacity for capturing probe molecules. The tailored pore size of the porous silicon also allows efficient immobilization of antibodies by surface adsorption, and does not require chemical immobilization. Monoclonal hK2 capture antibody (6B7) was dispensed onto P-Si chip using a piezoelectric dispenser. In total 13 × 13 arrays (169 spots) were spotted on the chip with its single spot volume of 300 pL. For an optimization of capture antibody condition, we firstly performed an immunoassay of the P-Si microarray under a titration series of hK2 in pure buffer (PBS) at three different antibody densities (75, 100 and 145 µg/mL). The best performance of the microarray platform was seen at 100 µg/mL of the capture antibody concentration (LOD was 100 fg/mL). The platform then was subsequently evaluated for a titration series of serum-spiked hK2 samples. The developed platform utilizes only 15 µL of serum per test and the total assay time is about 3 h, including immobilization of the capture antibody. The detection limit of the hK2 assay was 100 fg/mL in PBS buffer and 1 pg/mL in serum with a dynamic range of 106 (10−4 to 102 ng/mL). PMID:26007739

  16. A Highly Sensitive Porous Silicon (P-Si)-Based Human Kallikrein 2 (hK2) Immunoassay Platform toward Accurate Diagnosis of Prostate Cancer.

    PubMed

    Lee, Sang Wook; Hosokawa, Kazuo; Kim, Soyoun; Jeong, Ok Chan; Lilja, Hans; Laurell, Thomas; Maeda, Mizuo

    2015-05-22

    Levels of total human kallikrein 2 (hK2), a protein involved the pathology of prostate cancer (PCa), could be used as a biomarker to aid in the diagnosis of this disease. In this study, we report on a porous silicon antibody immunoassay platform for the detection of serum levels of total hK2. The surface of porous silicon has a 3-dimensional macro- and nanoporous structure, which offers a large binding capacity for capturing probe molecules. The tailored pore size of the porous silicon also allows efficient immobilization of antibodies by surface adsorption, and does not require chemical immobilization. Monoclonal hK2 capture antibody (6B7) was dispensed onto P-Si chip using a piezoelectric dispenser. In total 13 × 13 arrays (169 spots) were spotted on the chip with its single spot volume of 300 pL. For an optimization of capture antibody condition, we firstly performed an immunoassay of the P-Si microarray under a titration series of hK2 in pure buffer (PBS) at three different antibody densities (75, 100 and 145 µg/mL). The best performance of the microarray platform was seen at 100 µg/mL of the capture antibody concentration (LOD was 100 fg/mL). The platform then was subsequently evaluated for a titration series of serum-spiked hK2 samples. The developed platform utilizes only 15 µL of serum per test and the total assay time is about 3 h, including immobilization of the capture antibody. The detection limit of the hK2 assay was 100 fg/mL in PBS buffer and 1 pg/mL in serum with a dynamic range of 106 (10(-4) to 10(2) ng/mL).

  17. VAB Platform K(2) Lift & Install into Highbay 3

    NASA Image and Video Library

    2016-03-07

    Preparations are underway to lift the second half of the K-level work platforms for NASA’s Space Launch System (SLS) rocket up from High Bay 4 inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida. The platform will be lifted up and over the transfer aisle and then lowered into High Bay 3 for installation. It will be secured about 86 feet above the VAB floor, on tower E of the high bay. The K work platforms will provide access to the SLS core stage and solid rocket boosters during processing and stacking operations on the mobile launcher. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to High Bay 3 to support processing of the SLS and Orion spacecraft. A total of 10 levels of new platforms, 20 platform halves altogether, will surround the SLS rocket and Orion spacecraft.

  18. VAB Platform K(2) Lift & Install into Highbay 3

    NASA Image and Video Library

    2016-03-07

    A 250-ton crane is used to lift the second half of the K-level work platforms for NASA’s Space Launch System (SLS) rocket up from High Bay 4 inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida. The platform will be lifted up and over the transfer aisle and then lowered into High Bay 3 for installation. It will be secured about 86 feet above the VAB floor, on tower E of the high bay. The K work platforms will provide access to the SLS core stage and solid rocket boosters during processing and stacking operations on the mobile launcher. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to High Bay 3 to support processing of the SLS and Orion spacecraft. A total of 10 levels of new platforms, 20 platform halves altogether, will surround the SLS rocket and Orion spacecraft.

  19. VAB Platform K(2) Lift & Install into Highbay 3

    NASA Image and Video Library

    2016-03-07

    A 250-ton crane is used to lift the second half of the K-level work platforms for NASA’s Space Launch System (SLS) rocket up from High Bay 4 inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida. The platform is being lifted up and over the transfer aisle and will be lowered into High Bay 3 for installation. It will be secured about 86 feet above the VAB floor, on tower E of the high bay. The K work platforms will provide access to the SLS core stage and solid rocket boosters during processing and stacking operations on the mobile launcher. The Ground Systems Development and Operations Program is overseeing upgrades and modifications to High Bay 3 to support processing of the SLS and Orion spacecraft. A total of 10 levels of new platforms, 20 platform halves altogether, will surround the SLS rocket and Orion spacecraft.

  20. Contribution of calcaneal and leg segment rotations to ankle joint dorsiflexion in a weight-bearing task.

    PubMed

    Chizewski, Michael G; Chiu, Loren Z F

    2012-05-01

    Joint angle is the relative rotation between two segments where one is a reference and assumed to be non-moving. However, rotation of the reference segment will influence the system's spatial orientation and joint angle. The purpose of this investigation was to determine the contribution of leg and calcaneal rotations to ankle rotation in a weight-bearing task. Forty-eight individuals performed partial squats recorded using a 3D motion capture system. Markers on the calcaneus and leg were used to model leg and calcaneal segment, and ankle joint rotations. Multiple linear regression was used to determine the contribution of leg and calcaneal segment rotations to ankle joint dorsiflexion. Regression models for left (R(2)=0.97) and right (R(2)=0.97) ankle dorsiflexion were significant. Sagittal plane leg rotation had a positive influence (left: β=1.411; right: β=1.418) while sagittal plane calcaneal rotation had a negative influence (left: β=-0.573; right: β=-0.650) on ankle dorsiflexion. Sagittal plane rotations of the leg and calcaneus were positively correlated (left: r=0.84, P<0.001; right: r=0.80, P<0.001). During a partial squat, the calcaneus rotates forward. Simultaneous forward calcaneal rotation with ankle dorsiflexion reduces total ankle dorsiflexion angle. Rear foot posture is reoriented during a partial squat, allowing greater leg rotation in the sagittal plane. Segment rotations may provide greater insight into movement mechanics that cannot be explained via joint rotations alone. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Total Lightning Characteristics with Respect to Radar-Derived Mesocyclone Strength

    NASA Technical Reports Server (NTRS)

    Stough, Sarah M.; Carey, Lawrence D.; Schultz, Christopher J.

    2015-01-01

    Recent work investigating the microphysical and kinematic relationship between a storm's updraft, its total lightning production, and manifestations of severe weather has resulted in development of tools for improved nowcasting of storm intensity. The total lightning jump algorithm, which identifies rapid increases in total lightning flash rate that often precede severe events, has shown particular potential to benefit warning operations. Maximizing this capability of total lightning and its operational implementation via the lightning jump may best be done through its fusion with radar and radar-derived intensity metrics. Identification of a mesocyclone, or quasi-steady rotating updraft, in Doppler velocity is the predominant radar-inferred early indicator of severe potential in a convective storm. Fused lightning-radar tools that capitalize on the most robust intensity indicators would allow enhanced situational awareness for increased warning confidence. A foundational step toward such tools comes from a better understanding of the updraft-centric relationship between intensification of total lightning production and mesocyclone development and strength. The work presented here utilizes a sample of supercell case studies representing a spectrum of severity. These storms are analyzed with respect to total lightning flash rate and the lightning jump alongside mesocyclone strength derived objectively from the National Severe Storms Laboratory (NSSL) Mesocyclone Detection Algorithm (MDA) and maximum azimuthal shear through a layer. Early results indicate that temporal similarities exist in the trends between total lightning flash rate and low- to mid-level rotation in supercells. Other characteristics such as polarimetric signatures of rotation, flash size, and cloud-to-ground flash ratio are explored for added insight into the significance of these trends with respect to the updraft and related processes of severe weather production.

  2. Integrated micro-optofluidic platform for real-time detection of airborne microorganisms

    NASA Astrophysics Data System (ADS)

    Choi, Jeongan; Kang, Miran; Jung, Jae Hee

    2015-11-01

    We demonstrate an integrated micro-optofluidic platform for real-time, continuous detection and quantification of airborne microorganisms. Measurements of the fluorescence and light scattering from single particles in a microfluidic channel are used to determine the total particle number concentration and the microorganism number concentration in real-time. The system performance is examined by evaluating standard particle measurements with various sample flow rates and the ratios of fluorescent to non-fluorescent particles. To apply this method to real-time detection of airborne microorganisms, airborne Escherichia coli, Bacillus subtilis, and Staphylococcus epidermidis cells were introduced into the micro-optofluidic platform via bioaerosol generation, and a liquid-type particle collection setup was used. We demonstrate successful discrimination of SYTO82-dyed fluorescent bacterial cells from other residue particles in a continuous and real-time manner. In comparison with traditional microscopy cell counting and colony culture methods, this micro-optofluidic platform is not only more accurate in terms of the detection efficiency for airborne microorganisms but it also provides additional information on the total particle number concentration.

  3. Integrated micro-optofluidic platform for real-time detection of airborne microorganisms

    PubMed Central

    Choi, Jeongan; Kang, Miran; Jung, Jae Hee

    2015-01-01

    We demonstrate an integrated micro-optofluidic platform for real-time, continuous detection and quantification of airborne microorganisms. Measurements of the fluorescence and light scattering from single particles in a microfluidic channel are used to determine the total particle number concentration and the microorganism number concentration in real-time. The system performance is examined by evaluating standard particle measurements with various sample flow rates and the ratios of fluorescent to non-fluorescent particles. To apply this method to real-time detection of airborne microorganisms, airborne Escherichia coli, Bacillus subtilis, and Staphylococcus epidermidis cells were introduced into the micro-optofluidic platform via bioaerosol generation, and a liquid-type particle collection setup was used. We demonstrate successful discrimination of SYTO82-dyed fluorescent bacterial cells from other residue particles in a continuous and real-time manner. In comparison with traditional microscopy cell counting and colony culture methods, this micro-optofluidic platform is not only more accurate in terms of the detection efficiency for airborne microorganisms but it also provides additional information on the total particle number concentration. PMID:26522006

  4. Comparison of epidemiology and outcomes of arthroscopic rotator cuff repair for anterosuperior and posterosuperior rotator cuff tears.

    PubMed

    Teratani, Takeshi

    2017-12-01

    The purpose of this study was to investigate the prevalence, epidemiology, and outcomes of anterosuperior (A group) rotator cuff tears (RCTs) and posterosuperior (P group) RCTs treated by arthroscopic rotator cuff repair (ARCR). A total of 67 A group patients and 14 P group patients were included in the study. The prevalence of the A group (82.3%) was significantly higher than that of the P group (17.7%). The outcomes in both groups were good, even though the A group had a higher rate of injury to the LHB than the P group. Level III, case-control Study, treatment study.

  5. Reducing N losses through surface runoff from rice-wheat rotation by improving fertilizer management.

    PubMed

    Cao, Yansheng; Sun, Huifeng; Liu, Yaqin; Fu, Zishi; Chen, Guifa; Zou, Guoyan; Zhou, Sheng

    2017-02-01

    To better understand N runoff losses from rice-wheat rotation and demonstrate the effectiveness of improved fertilizer management in reducing N runoff losses, a field study was conducted for three consecutive rice-wheat rotations. Nitrogen losses through surface runoff were measured for five treatments, including CK without N application, C200, C300 simulating the conventional practices, CO200, and CO300. Optimum N rate was applied for C200 and CO200, and 30% of chemical fertilizer was substituted with organic fertilizer for CO200 and CO300 with respect to C200 and C300, respectively. Rice season had higher runoff coefficients than wheat season. Approximately 52% of total N was lost as NH 4 + -N in rice season, ranging from 21 to 83%, and in wheat season, the proportion of NO 3 - -N in total N averaged 53% with a variation from 38 to 67%. The N treatments lost less total N in rice season (1.67-10.7 kg N ha -1 ) than in wheat season (1.72-17.1 kg N ha -1 ). These suggested that a key to controlling N runoff losses from rice-wheat rotation was to limit NO 3 - -N accumulation in wheat season. In both seasons, N runoff losses for C200 and CO300 were lower than those for C300. CO200 better cut N losses than C200 and CO300, with 64 and 57% less N in rice and wheat seasons than C300, respectively. Compared with the conventional practices, optimum N inputs integrated with co-application of organic and chemical fertilizers could reduce N runoff losses with a better N balance under rice-wheat rotation.

  6. An acute care surgery rotation contributes significant general surgical operative volume to residency training compared with other rotations.

    PubMed

    Stanley, Matthew D; Davenport, Daniel L; Procter, Levi D; Perry, Jacob E; Kearney, Paul A; Bernard, Andrew C

    2011-03-01

    Surgical resident rotations on trauma services are criticized for little operative experience and heavy workloads. This has resulted in diminished interest in trauma surgery among surgical residents. Acute care surgery (ACS) combines trauma and emergency/elective general surgery, enhancing operative volume and balancing operative and nonoperative effort. We hypothesize that a mature ACS service provides significant operative experience. A retrospective review was performed of ACGME case logs of 14 graduates from a major, academic, Level I trauma center program during a 3-year period. Residency Review Committee index case volumes during the fourth and fifth years of postgraduate training (PGY-4 and PGY-5) ACS rotations were compared with other service rotations: in total and per resident week on service. Ten thousand six hundred fifty-four cases were analyzed for 14 graduates. Mean cases per resident was 432 ± 57 in PGY-4, 330 ± 40 in PGY-5, and 761 ± 67 for both years combined. Mean case volume on ACS for both years was 273 ± 44, which represented 35.8% (273 of 761) of the total experience and exceeded all other services. Residents averaged 8.9 cases per week on the ACS service, which exceeded all other services except private general surgery, gastrointestinal/minimally invasive surgery, and pediatric surgery rotations. Disproportionately more head/neck, small and large intestine, gastric, spleen, laparotomy, and hernia cases occurred on ACS than on other services. Residents gain a large operative experience on ACS. An ACS model is viable in training, provides valuable operative experience, and should not be considered a drain on resident effort. Valuable ACS rotation experiences as a resident may encourage graduates to pursue ACS as a career. Copyright © 2011 by Lippincott Williams & Wilkins

  7. Effect of deltoid tension and humeral version in reverse total shoulder arthroplasty: a biomechanical study.

    PubMed

    Henninger, Heath B; Barg, Alexej; Anderson, Andrew E; Bachus, Kent N; Tashjian, Robert Z; Burks, Robert T

    2012-04-01

    No clear recommendations exist regarding optimal humeral component version and deltoid tension in reverse total shoulder arthroplasty (TSA). A biomechanical shoulder simulator tested humeral versions (0°, 10°, 20° retroversion) and implant thicknesses (-3, 0, +3 mm from baseline) after reverse TSA in human cadavers. Abduction and external rotation ranges of motion as well as abduction and dislocation forces were quantified for native arms and arms implanted with 9 combinations of humeral version and implant thickness. Resting abduction angles increased significantly (up to 30°) after reverse TSA compared with native shoulders. With constant posterior cuff loads, native arms externally rotated 20°, whereas no external rotation occurred in implanted arms (20° net internal rotation). Humeral version did not affect rotational range of motion but did alter resting abduction. Abduction forces decreased 30% vs native shoulders but did not change when version or implant thickness was altered. Humeral center of rotation was shifted 17 mm medially and 12 mm inferiorly after implantation. The force required for lateral dislocation was 60% less than anterior and was not affected by implant thickness or version. Reverse TSA reduced abduction forces compared with native shoulders and resulted in limited external rotation and abduction ranges of motion. Because abduction force was reduced for all implants, the choice of humeral version and implant thickness should focus on range of motion. Lateral dislocation forces were less than anterior forces; thus, levering and inferior/posterior impingement may be a more probable basis for dislocation (laterally) than anteriorly directed forces. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  8. Effect of lateral offset center of rotation in reverse total shoulder arthroplasty: a biomechanical study.

    PubMed

    Henninger, Heath B; Barg, Alexej; Anderson, Andrew E; Bachus, Kent N; Burks, Robert T; Tashjian, Robert Z

    2012-09-01

    Lateral offset center of rotation (COR) reduces the incidence of scapular notching and potentially increases external rotation range of motion (ROM) after reverse total shoulder arthroplasty (rTSA). The purpose of this study was to determine the biomechanical effects of changing COR on abduction and external rotation ROM, deltoid abduction force, and joint stability. A biomechanical shoulder simulator tested cadaveric shoulders before and after rTSA. Spacers shifted the COR laterally from baseline rTSA by 5, 10, and 15 mm. Outcome measures of resting abduction and external rotation ROM, and abduction and dislocation (lateral and anterior) forces were recorded. Resting abduction increased 20° vs native shoulders and was unaffected by COR lateralization. External rotation decreased after rTSA and was unaffected by COR lateralization. The deltoid force required for abduction significantly decreased 25% from native to baseline rTSA. COR lateralization progressively eliminated this mechanical advantage. Lateral dislocation required significantly less force than anterior dislocation after rTSA, and both dislocation forces increased with lateralization of the COR. COR lateralization had no influence on ROM (adduction or external rotation) but significantly increased abduction and dislocation forces. This suggests the lower incidence of scapular notching may not be related to the amount of adduction deficit after lateral offset rTSA but may arise from limited impingement of the humeral component on the lateral scapula due to a change in joint geometry. Lateralization provides the benefit of increased joint stability, but at the cost of increasing deltoid abduction forces. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  9. KSC-02pd0537

    NASA Image and Video Library

    2002-04-22

    KENNEDY SPACE CENTER, FLA. -- Inside the Orbiter Processing Facility, spectators watch as Endeavour is rolled out of the bay on top of a transporter. The orbiter is being moved to the Vehicle Assembly Building for mating to the External Tank/Solid Rocket Boosters atop the Mobile Launcher Platform. Endeavour is targeted to launch May 30, 2002, on mission STS-111 to the International Space Station. Mission goals include delivering and installing the Mobile Base System to complete the Canadian Mobile Service System and carrying the Expedition 5 crew to the Station for rotation with Expedition 4.

  10. Active Thermal Architecture for Cryogenic Optical Instrumentation (ATACOI)

    NASA Technical Reports Server (NTRS)

    Swenson, Charles; Hunter, Roger C.; Baker, Christopher E.

    2018-01-01

    The Active Thermal Architecture for Cryogenic Optical Instrumentation (ATACOI) project will demonstrate an advanced thermal control system for CubeSats and enable the use of cryogenic electro-optical instrumentation on small satellite platforms. Specifically, the project focuses on the development of a deployable solar tracking radiator, a rotationally flexible rotary union fluid joint, and a thermal/vibrational isolation system for miniature cryogenic detectors. This technology will represent a significant improvement over the current state of the art for CubeSat thermal control, which generally relies on simple passive and conductive methods.

  11. Motion at the Tibial and Polyethylene Component Interface in a Mobile-Bearing Total Ankle Replacement.

    PubMed

    Lundeen, Gregory A; Clanton, Thomas O; Dunaway, Linda J; Lu, Minggen

    2016-08-01

    Normal biomechanics of the ankle joint includes sagittal as well as axial rotation. Current understanding of mobile-bearing motion at the tibial-polyethylene interface in total ankle arthroplasty (TAA) is limited to anterior-posterior (AP) motion of the polyethylene component. The purpose of our study was to define the motion of the polyethylene component in relation to the tibial component in a mobile-bearing TAA in both the sagittal and axial planes in postoperative patients. Patients who were a minimum of 12 months postoperative from a third-generation mobile-bearing TAA were identified. AP images were saved at maximum internal and external rotation, and the lateral images were saved in maximum plantarflexion and dorsiflexion. Sagittal range of motion and AP translation of the polyethylene component were measured from the lateral images. Axial rotation was determined by measuring the relative position of the 2 wires within the polyethylene component on AP internal and external rotation imaging. This relationship was compared to a table developed from fluoroscopic images taken at standardized degrees of axial rotation of a nonimplanted polyethylene with the associated length relationship of the 2 imbedded wires. Sixteen patients were included in this investigation, 9 (56%) were male and average age was 68 (range, 49-80) years. Time from surgery averaged 25 (range, 12-38) months. Total sagittal range of motion averaged 23±9 (range, 9-33) degrees. Axial motion for total internal and external rotation of the polyethylene component on the tibial component averaged 6±5 (range, 0-18) degrees. AP translation of the polyethylene component relative to the tibial component averaged 1±1 (range, 0-3) mm. There was no relationship between axial rotation or AP translation of the polyethylene component and ankle joint range of motion (P > .05). To our knowledge, this is the first investigation to measure axial and sagittal motion of the polyethylene component at the tibial implant interface in patients following a mobile-bearing TAA. Based on outcome scores and range-of-motion measurements, we believe the patients in this study are a representative cross section of subjects compared to other TAA research results. The results from this investigation indicate the potential for a mobile-bearing TAA to fall within the parameters of normal polyaxial ankle motion. The multiplanar articulation in a mobile-bearing TAA may reduce excessively high peak pressures during the complex dynamic tibial and talar motion, which may have a positive influence on gait pattern, polyethylene wear, and implant longevity. Level IV, case series. © The Author(s) 2016.

  12. Measuring intra-operative decision-making during laparoscopic cholecystectomy: validity evidence for a novel interactive Web-based assessment tool.

    PubMed

    Madani, Amin; Watanabe, Yusuke; Bilgic, Elif; Pucher, Philip H; Vassiliou, Melina C; Aggarwal, Rajesh; Fried, Gerald M; Mitmaker, Elliot J; Feldman, Liane S

    2017-03-01

    Errors in judgment during laparoscopic cholecystectomy can lead to bile duct injuries and other complications. Despite correlations between outcomes, expertise and advanced cognitive skills, current methods to evaluate these skills remain subjective, rater- and situation-dependent and non-systematic. The purpose of this study was to develop objective metrics using a Web-based platform and to obtain validity evidence for their assessment of decision-making during laparoscopic cholecystectomy. An interactive online learning platform was developed ( www.thinklikeasurgeon.com ). Trainees and surgeons from six institutions completed a 12-item assessment, developed based on a cognitive task analysis. Five items required subjects to draw their answer on the surgical field, and accuracy scores were calculated based on an algorithm derived from experts' responses ("visual concordance test", VCT). Test-retest reliability, internal consistency, and correlation with self-reported experience, Global Operative Assessment of Laparoscopic Skills (GOALS) score and Objective Performance Rating Scale (OPRS) score were calculated. Questionnaires were administered to evaluate the platform's usability, feasibility and educational value. Thirty-nine subjects (17 surgeons, 22 trainees) participated. There was high test-retest reliability (intraclass correlation coefficient = 0.95; n = 10) and internal consistency (Cronbach's α = 0.87). The assessment demonstrated significant differences between novices, intermediates and experts in total score (p < 0.01) and VCT score (p < 0.01). There was high correlation between total case number and total score (ρ = 0.83, p < 0.01) and between total case number and VCT (ρ = 0.82, p < 0.01), and moderate to high correlations between total score and GOALS (ρ = 0.66, p = 0.05), VCT and GOALS (ρ = 0.83, p < 0.01), total score and OPRS (ρ = 0.67, p = 0.04), and VCT and OPRS (ρ = 0.78, p = 0.01). Most subjects agreed or strongly agreed that the platform and assessment was easy to use [n = 29 (78 %)], facilitates learning intra-operative decision-making [n = 28 (81 %)], and should be integrated into surgical training [n = 28 (76 %)]. This study provides preliminary validity evidence for a novel interactive platform to objectively assess decision-making during laparoscopic cholecystectomy.

  13. Rotating Wheel Wake

    NASA Astrophysics Data System (ADS)

    Lombard, Jean-Eloi; Xu, Hui; Moxey, Dave; Sherwin, Spencer

    2016-11-01

    For open wheel race-cars, such as Formula One, or IndyCar, the wheels are responsible for 40 % of the total drag. For road cars, drag associated to the wheels and under-carriage can represent 20 - 60 % of total drag at highway cruise speeds. Experimental observations have reported two, three or more pairs of counter rotating vortices, the relative strength of which still remains an open question. The near wake of an unsteady rotating wheel. The numerical investigation by means of direct numerical simulation at ReD =400-1000 is presented here to further the understanding of bifurcations the flow undergoes as the Reynolds number is increased. Direct numerical simulation is performed using Nektar++, the results of which are compared to those of Pirozzoli et al. (2012). Both proper orthogonal decomposition and dynamic mode decomposition, as well as spectral analysis are leveraged to gain unprecedented insight into the bifurcations and subsequent topological differences of the wake as the Reynolds number is increased.

  14. Measurement of total electron content of midlatitude ionosphere and protonosphere via Faraday rotation and group relay techniques using transmission from geostationary satellites ATS-3 and ATS-6

    NASA Technical Reports Server (NTRS)

    Paul, M. P.

    1982-01-01

    Measurement of integrated columnar electron content and total electron content for the local ionosphere and the overlying protonosphere via Faraday rotation and group delay techniques has proven very useful. A field station was established having the geographic location of 31.5 deg N latitude and 91.06 deg W longitude to accomplish these objectives. A polarimeter receiving system was set up in the beginning to measure the Faraday rotation of 137.35 MHz radio signal from geostationary satellite ATS 3 to yield the integrated columnar electron content of the local ionosphere. The measurement was continued regularly, and the analysis of the data thus collected provided a synopsis of the statistical variation of the ionosphere along with the transient variations that occurred during the periods of geomagnetic and other disturbances.

  15. Harvesting costs and utilization of hardwood plantations

    Treesearch

    Tim P. McDonald; Bryce J. Stokes

    1994-01-01

    The use of short rotation, intensive culture (SRIC) practices in hardwoods to meet fiber supply needs is becoming increasingly widespread. Total plated area of short rotation hardwood fiber plantations is currently about 22,000 ha (McDonald and Stokes 1993). That figure should certainly to grow in response to public concerns over loss of natural hardwood stands. With...

  16. A Rotating Stellar Collapse Model for Supernova 1987A

    NASA Astrophysics Data System (ADS)

    Nakamura, T.; Fukugita, M.

    It is shown that the bunch structure of the Kamiokande neutrino events associated with SN 1987A can be naturally understood, if one assumes that the core of the progenitor star was rotating moderately with q(≡Jc/GM2) ≈ 3 with J the total angular momentum and M the gravitational mass of the core.

  17. Thinning even-aged, upland oak stands

    Treesearch

    Donald E. Hilt; Martin E. Dale

    1989-01-01

    Thinning produces bigger and better trees faster. Thinning removes poor quality trees and concentrates growth on the best. Total wood production increases because trees that would otherwise die from competition are harvested. Rotation ages for sawtimber can be shortened as much as 20 years. Or, we can grow bigger, more valuable trees using the same rotation age as an...

  18. The influence of motion control shoes on the running gait of mature and young females.

    PubMed

    Lilley, Kim; Stiles, Vicky; Dixon, Sharon

    2013-03-01

    This study compared the running gait of mature and young females, and investigated the effect of a motion control shoe. First, it was hypothesised that in a neutral shoe, mature females would display significantly greater rearfoot eversion, knee internal rotation and external adductor moments when compared to a younger group. Secondly, the motion control shoe would reduce rearfoot eversion and knee internal rotation in both groups. Thirdly it was hypothesised that the motion control shoe would increase knee external adductor moment, through an increase in knee varus and moment arm. 15 mature (40-60 years) and 15 young (18-25 years) females performed 10 running trials at 3.5ms(-1)±5% over a force platform. Two shoes were tested, the Adidas Supernova Glide (neutral), and the Adidas Supernova Sequence (motion control). Ankle and knee joint dynamics were analysed for the right leg, and the mean of ten trials was calculated. Joint moments were calculated using inverse dynamics. In the neutral condition, mature females presented greater peak rearfoot eversion, knee internal rotation, and external adductor moments than young females (p<0.05). A motion control shoe significantly reduced peak rearfoot eversion and knee internal rotation among both groups (p<0.05). No between shoe differences in knee external adductor moment were observed. A motion control shoe is recommended to reduce risk of injury associated with rearfoot eversion and knee internal rotation in mature females. However since the knee external adductor moment is a variable commonly associated with medial knee loading it is suggested that alternative design features are required to influence this moment. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Effects of foot rotation positions on knee valgus during single-leg drop landing: Implications for ACL injury risk reduction.

    PubMed

    Teng, P S P; Kong, P W; Leong, K F

    2017-06-01

    Non-contact anterior cruciate ligament (ACL) injuries commonly occur when athletes land in high risk positions such as knee valgus. The position of the foot at landing may influence the transmission of forces from the ankle to the knee. Using an experimental approach to manipulate foot rotation positions, this study aimed to provide new insights on how knee valgus during single-leg landing may be influenced by foot positions. Eleven male recreational basketball players performed single-leg drop landings from a 30-cm high platform in three foot rotation positions (toe-in, toe-forward and toe-out) at initial contact. A motion capture system and a force plate were used to measure lower extremity kinematics and kinetics. Knee valgus angles at initial contact (KVA) and maximum knee valgus moments (KVM), which were known risk factors associated with ACL injury, were measured. A one-way repeated measures Analysis of Variance was conducted (α=0.05) to compare among the three foot positions. Foot rotation positions were found to have a significant effect on KVA (p<0.001, η 2 =0.66) but the difference between conditions (about 1°) was small and not clinically meaningful. There was a significant effect of foot position on KVM (p<0.001, η 2 =0.55), with increased moment observed in the toe-out position as compared to toe-forward (p=0.012) or toe-in positions (p=0.002). When landing with one leg, athletes should avoid extreme toe-out foot rotation positions to minimise undesirable knee valgus loading associated with non-contact ACL injury risks. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Laboratory Rotational Spectroscopy of the Interstellar Diatomic Hydride Ion SH+ (X 3Σ-)

    NASA Astrophysics Data System (ADS)

    Halfen, DeWayne; Ziurys, Lucy M.

    2016-06-01

    Diatomic hydride are among the most common molecular species in the interstellar medium (ISM). The low molecular mass and thus moments of inertia cause their rotational spectra to lie principally in the submillimeter and far-infrared regions. Diatomic hydrides, both neutral (MH) and ionic (MH+) forms, are also basic building blocks of interstellar chemistry. In ionic form, they may be the “hidden” carriers of refractory elements in dense gas. They are therefore extremely good targets for space-borne and airborne platforms such as Herschel, SOFIA, and SAFIR. However, in order to detect these species in the ISM, their rotational spectra must first be measured in the laboratory. To date, there is very little high resolution data available for many hydride species, in particular the ionic form. Using submillimeter/THz direct absorption methods in the Ziurys laboratory, spectra of the interstellar diatomic hydride SH+ (X 3Σ-) have been recorded. Recent work has concerned measurement of all three fine structure components of the fundamental rotational transition N = 1 ← 0 in the range 345 - 683 GHz. SH+ was generated from H2S and argon in an AC discharge. The data have been analyzed, and spectroscopic constants for this species have been refined. SH+ is found in Photon Dominated Regions (PDRs) and X-ray Dominated Regions (XDRs) and is thought to trace energetic processes in the ISM. These current measurements confirm recent observations of this species at submillimeter/THz wavelengths with ALMA and other ground-based telescopes.

Top