Sample records for rotation

  1. Rotational joint assembly and method for constructing the same

    NASA Technical Reports Server (NTRS)

    Bandera, Pablo (Inventor); Buchele, Paul (Inventor)

    2012-01-01

    A rotational joint assembly and a method for constructing a rotational joint assembly are provided. The rotational joint assembly includes a first rotational component, a second rotational component coupled to the first rotational component such that the second rotational component is rotatable relative to the first rotational component in first and second rotational directions about an axis, and a flexure member, being deflectable in first and second deflection directions, coupled to at least one of the first and second rotational components such that when the second rotational component is rotated relative to the first rotational component in each of the first and second rotational directions about the axis, the flexure member is deflected in the first deflection direction and exerts a force on the second rotational component opposing the rotation.

  2. In touch with mental rotation: interactions between mental and tactile rotations and motor responses.

    PubMed

    Lohmann, Johannes; Rolke, Bettina; Butz, Martin V

    2017-04-01

    Although several process models have described the cognitive processing stages that are involved in mentally rotating objects, the exact nature of the rotation process itself remains elusive. According to embodied cognition, cognitive functions are deeply grounded in the sensorimotor system. We thus hypothesized that modal rotation perceptions should influence mental rotations. We conducted two studies in which participants had to judge if a rotated letter was visually presented canonically or mirrored. Concurrently, participants had to judge if a tactile rotation on their palm changed direction during the trial. The results show that tactile rotations can systematically influence mental rotation performance in that same rotations are favored. In addition, the results show that mental rotations produce a response compatibility effect: clockwise mental rotations facilitate responses to the right, while counterclockwise mental rotations facilitate responses to the left. We conclude that the execution of mental rotations activates cognitive mechanisms that are also used to perceive rotations in different modalities and that are associated with directional motor control processes.

  3. Response of plasma rotation to resonant magnetic perturbations in J-TEXT tokamak

    NASA Astrophysics Data System (ADS)

    Yan, W.; Chen, Z. Y.; Huang, D. W.; Hu, Q. M.; Shi, Y. J.; Ding, Y. H.; Cheng, Z. F.; Yang, Z. J.; Pan, X. M.; Lee, S. G.; Tong, R. H.; Wei, Y. N.; Dong, Y. B.; J-TEXT Team

    2018-03-01

    The response of plasma toroidal rotation to the external resonant magnetic perturbations (RMP) has been investigated in Joint Texas Experimental Tokamak (J-TEXT) ohmic heating plasmas. For the J-TEXT’s plasmas without the application of RMP, the core toroidal rotation is in the counter-current direction while the edge rotation is near zero or slightly in the co-current direction. Both static RMP experiments and rotating RMP experiments have been applied to investigate the plasma toroidal rotation. The core toroidal rotation decreases to lower level with static RMP. At the same time, the edge rotation can spin to more than 20 km s-1 in co-current direction. On the other hand, the core plasma rotation can be slowed down or be accelerated with the rotating RMP. When the rotating RMP frequency is higher than mode frequency, the plasma rotation can be accelerated to the rotating RMP frequency. The plasma confinement is improved with high frequency rotating RMP. The plasma rotation is decelerated to the rotating RMP frequency when the rotating RMP frequency is lower than the mode frequency. The plasma confinement also degrades with low frequency rotating RMP.

  4. The role of pairing an anesthesiology rotation with the general surgery clerkship: positive impact on surgical and perioperative education

    PubMed Central

    2018-01-01

    Background The use of an anesthesiology rotation in the realm of surgical education is not very well studied. Several studies show the importance of an anesthesiology rotation in the grand scheme of undergraduate medical education. However, its importance in perioperative medicine and surgical education is not very well understood. This study attempts to look at this relationship and determine whether or not a temporal relationship between this anesthesiology rotation and a surgical rotation is important. Methods I used an online survey tool to survey medical students who took the anesthesiology rotation (required rotation) in 2014 and 2015 (when rotation was coupled to surgical rotation) and compared those data to the data of students who took the rotation in 2016 (when the rotation was not coupled to surgery). I asked several questions looking at the importance of the anesthesiology rotation to surgical education and to perioperative medicine. Results Having a required anesthesiology rotation appears to add value to the general surgery rotation in undergraduate medical education. Furthermore, when this rotation is paired with the general surgery rotation, it appears that the students learn more about perioperative medicine than when the rotation is paired with other “advanced” rotation. Conclusion The pairing of anesthesiology with a general surgery rotation does indeed improve the perioperative medicine education and knowledge of students. Students appreciate having a week of anesthesiology with the surgical rotation, and they note that it adds value to the general surgery rotation. PMID:29445309

  5. Three-Dimensional Mapping of Microenvironmental Control of Methyl Rotational Barriers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hembree, William I; Baudry, Jerome Y

    2011-01-01

    Sterical (van der Waals-induced) rotational barriers of methyl groups are investigated theoretically, using ab initio and empirical force field calculations, for various three-dimensional microenvironmental conditions around the methyl group rotator of a model neopentane molecule. The destabilization (reducing methyl rotational barriers) or stabilization (increasing methyl rotational barriers) of the staggered conformation of the methyl rotator depends on a combination of microenvironmental contributions from (i) the number of atoms around the rotator, (ii) the distance between the rotator and the microenvironmental atoms, and (iii) the dihedral angle between the stator, rotator, and molecular environment around the rotator. These geometrical criteria combinemore » their respective effects in a linearly additive fashion, with no apparent cooperative effects, and their combination in space around a rotator may increase, decrease, or leave the rotator s rotational barrier unmodified. This is exemplified in a geometrical analysis of the alanine dipeptide crystal where microenvironmental effects on methyl rotators barrier of rotation fit the geometrical mapping described in the neopentane model.« less

  6. Sample rotating turntable kit for infrared spectrometers

    DOEpatents

    Eckels, Joel Del [Livermore, CA; Klunder, Gregory L [Oakland, CA

    2008-03-04

    An infrared spectrometer sample rotating turntable kit has a rotatable sample cup containing the sample. The infrared spectrometer has an infrared spectrometer probe for analyzing the sample and the rotatable sample cup is adapted to receive the infrared spectrometer probe. A reflectance standard is located in the rotatable sample cup. A sleeve is positioned proximate the sample cup and adapted to receive the probe. A rotator rotates the rotatable sample cup. A battery is connected to the rotator.

  7. Mental object rotation and the planning of hand movements.

    PubMed

    Wohlschläger, A

    2001-05-01

    Recently, we showed that the simultaneous execution of rotational hand movements interferes with mental object rotation, provided that the axes of rotation coincide in space. We hypothesized that mental object rotation and the programming of rotational hand movements share a common process presumably involved in action planning. Two experiments are reported here that show that the mere planning of a rotational hand movement is sufficient to cause interference with mental object rotation. Subjects had to plan different spatially directed hand movements that they were asked to execute only after they had solved a mental object rotation task. Experiment 1 showed that mental object rotation was slower if hand movements were planned in a direction opposite to the presumed mental rotation direction, but only if the axes of hand rotation and mental object rotation were parallel in space. Experiment 2 showed that this interference occurred independent of the preparatory hand movements observed in Experiment 1. Thus, it is the planning of hand movements and not their preparation or execution that interferes with mental object rotation. This finding underlines the idea that mental object rotation is an imagined (covert) action, rather than a pure visual-spatial imagery task, and that the interference between mental object rotation and rotational hand movements is an interference between goals of actions.

  8. Hip rotation range of motion in sitting and prone positions in healthy Japanese adults

    PubMed Central

    Han, Heonsoo; Kubo, Akira; Kurosawa, Kazuo; Maruichi, Shizuka; Maruyama, Hitoshi

    2015-01-01

    [Purpose] The aim of this study was to elucidate the difference in hip external and internal rotation ranges of motion (ROM) between the prone and sitting positions. [Subjects] The subjects included 151 students. [Methods] Hip rotational ROM was measured with the subjects in the prone and sitting positions. Two-way repeated measures analysis of variance (ANOVA) was used to analyze ipsilateral hip rotation ROM in the prone and sitting positions in males and females. The total ipsilateral hip rotation ROM was calculated by adding the measured values for external and internal rotations. [Results] Ipsilateral hip rotation ROM revealed significant differences between two positions for both left and right internal and external rotations. Hip rotation ROM was significantly higher in the prone position than in the sitting position. Hip rotation ROM significantly differed between the men and women. Hip external rotation ROM was significantly higher in both positions in men; conversely, hip internal rotation ROM was significantly higher in both positions in women. [Conclusion] Hip rotation ROM significantly differed between the sexes and between the sitting and prone positions. Total ipsilateral hip rotation ROM, total angle of external rotation, and total angle of internal rotation of the left and right hips greatly varied, suggesting that hip joint rotational ROM is widely distributed. PMID:25729186

  9. Infant perception of the rotating Kanizsa square.

    PubMed

    Yoshino, Daisuke; Idesawa, Masanori; Kanazawa, So; Yamaguchi, Masami K

    2010-04-01

    This study examined the perception of the rotating Kanizsa square by using a fixed-trial familiarization method. If the Kanizsa square is rotated across the pacmen, adult observers perceive not only a rotating illusory square, but also an illusory expansion/contraction motion of this square. The phenomenon is called a "rotational dynamic illusion". In experiments 1 and 2, we investigated whether infants perceived the rotational dynamic illusion, finding that 3-8-month-old infants perceived the rotational dynamic illusion as a simple rotation of the Kanizsa square. In experiment 3, we investigated whether infants perceived the rotational dynamic illusion as a rotation of the Kanizsa square or as a deformation of shape, finding that 3-4-month-old infants did perceive the rotational dynamic illusion as a rotation of the Kanizsa square. Our results show that while 3-8-month-old infants perceive the rotating Kanizsa square, however, it is difficult for the infants to extract expansion/contraction motion from the rotational dynamic illusion. Copyright 2010 Elsevier Inc. All rights reserved.

  10. Rotational nonequilibrium mechanisms in pulsed H/sub 2/+F/sub 2/ chain reaction lasers. 2: Effect of VR energy exchange

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerber, R.L.; Brown, R.C.; Emery, K.A.

    1980-01-15

    The occurrence of pure rotational-to-rotational lasing from high J levels suggests that present rotational nonequilibrium mechanisms are inadequate to explain all lasing behavior of the HF laser. A possible mechanism for explaining this behavior is vibrational-to-rotational energy transfer. The usual assumption that vibrational relaxation occurs with rotational levels at equilibrium at the translational temperature is replaced with a near resonant multiquanta VR process that results in the formation of highly excited rotational states. Computer simulations incorporating VR relaxation predicted significant occurrence of rotational lasing. A simpler model that produced rotational nonequilibrium from pumping and P-branch lasing did not exhibit rotationalmore » lasing. Rotational lasing did not decrease energy available to P-branch lasing and produced effects resembling an increase in rotational relaxation rates. Rotational lasing is very sensitive to kinetics for both VR energy exchange and rotational relaxation.« less

  11. Omni-directional and holonomic rolling platform with decoupled rotational and translational degrees of freedom

    DOEpatents

    Pin, F.G.; Killough, S.M.

    1994-12-20

    A wheel assembly includes a support, a cage rotatably mounted on the support and having a longitudinal rotation axis, a first ball wheel rotatably mounted in the cage and having a rotation axis orthogonal to the rotation axis of the cage, and a second ball wheel rotatably mounted in the cage and having a rotation axis orthogonal to the rotation axis or the cage and to the rotation axis of the first ball wheel. A control circuit includes a photodetector signal which indicates ground contact for each ball wheel, and a tachometer which indicates actual drive shaft velocity. 6 figures.

  12. Omni-directional and holonomic rolling platform with decoupled rotational and translational degrees of freedom

    DOEpatents

    Pin, Francois G.; Killough, Stephen M.

    1994-01-01

    A wheel assembly includes a support, a cage rotatably mounted on the support and having a longitudinal rotation axis, a first ball wheel rotatably mounted in the cage and having a rotation axis orthogonal to the rotation axis of the cage, and a second ball wheel rotatably mounted in the cage and having a rotation axis orthogonal to the rotation axis or the cage and to the rotation axis of the first ball wheel. A control circuit includes a photodetector signal which indicates ground contact for each ball wheel, and a tachometer which indicates actual drive shaft velocity.

  13. Visual perception of axes of head rotation

    PubMed Central

    Arnoldussen, D. M.; Goossens, J.; van den Berg, A. V.

    2013-01-01

    Registration of ego-motion is important to accurately navigate through space. Movements of the head and eye relative to space are registered through the vestibular system and optical flow, respectively. Here, we address three questions concerning the visual registration of self-rotation. (1) Eye-in-head movements provide a link between the motion signals received by sensors in the moving eye and sensors in the moving head. How are these signals combined into an ego-rotation percept? We combined optic flow of simulated forward and rotational motion of the eye with different levels of eye-in-head rotation for a stationary head. We dissociated simulated gaze rotation and head rotation by different levels of eye-in-head pursuit. We found that perceived rotation matches simulated head- not gaze-rotation. This rejects a model for perceived self-rotation that relies on the rotation of the gaze line. Rather, eye-in-head signals serve to transform the optic flow's rotation information, that specifies rotation of the scene relative to the eye, into a rotation relative to the head. This suggests that transformed visual self-rotation signals may combine with vestibular signals. (2) Do transformed visual self-rotation signals reflect the arrangement of the semi-circular canals (SCC)? Previously, we found sub-regions within MST and V6+ that respond to the speed of the simulated head rotation. Here, we re-analyzed those Blood oxygenated level-dependent (BOLD) signals for the presence of a spatial dissociation related to the axes of visually simulated head rotation, such as have been found in sub-cortical regions of various animals. Contrary, we found a rather uniform BOLD response to simulated rotation along the three SCC axes. (3) We investigated if subject's sensitivity to the direction of the head rotation axis shows SCC axes specifcity. We found that sensitivity to head rotation is rather uniformly distributed, suggesting that in human cortex, visuo-vestibular integration is not arranged into the SCC frame. PMID:23919087

  14. Rotation in Xenopus laevis embryos during the second cell cycle.

    PubMed

    Starodubov, Sergey M; Golychenkov, Vladimir A

    2009-01-01

    Using time-lapse video recording and comparing successive digital images, we found that 38% of Xenopus laevis embryos (n=118) exhibited rotation during the second cell cycle. This rotation, which we term the second rotation, started approximately during the appearance of the first cleavage furrow and proceeded clockwise or counterclockwise around the vertical axis. Rotations lasted for 5-30 minutes, i.e. up to the beginning of the third cell cycle. The mean rotation angle was 36.4 degrees, with a maximum rotation of 77 degrees. No mortality was observed among the embryos exhibiting rotation. The second rotation was observed to be similar to the well-known fertilization rotation which takes place during the first cell cycle. The possible nature and significance of the second rotation are discussed.

  15. Influence of Component Rotation in Total Knee Arthroplasty on Tibiofemoral Kinematics-A Cadaveric Investigation.

    PubMed

    Maderbacher, Guenther; Keshmiri, Armin; Springorum, Hans R; Maderbacher, Hermann; Grifka, Joachim; Baier, Clemens

    2017-09-01

    Physiological tibiofemoral kinematics have been shown to be important for good knee function after total knee arthroplasty (TKA). The purpose of the present study was to investigate the influence of component rotation on tibiofemoral kinematics during knee flexion. We asked which axial component alignment best reconstructs physiological tibiofemoral kinematics and which combinations should be avoided. Ten healthy cadaveric knees were examined. By means of a navigational device, tibiofemoral kinematics between 0° and 90° of flexion were assessed before and after TKA using the following different rotational component alignment: femoral components: ligament balanced, 6° internal, 3° external rotation, and 6° external rotation in relation to the posterior condylar line; tibial components: self-adapted, 6° internal rotation, and 6° external rotation. Physiological tibiofemoral kinematics could be partly reconstructed by TKA. Ligament-balanced femoral rotation and 6° femoral external rotation both in combination with 6° tibial component external rotation, and 3° femoral external rotation in combination with 6° tibial component internal rotation or self-aligning tibial component were able to restore tibial longitudinal rotation. Largest kinematical differences were found for the combination femoral component internal and tibial component external rotations. From a kinematic-based view, surgeons should avoid internal rotation of femoral components. However, even often recommended combinations of rotational component alignment (3° femoral external and tibial external rotation) significantly change tibiofemoral kinematics. Self-aligning tibial components solely restored tibiofemoral kinematics with the combination of 3° femoral component of external rotation. For the future, navigational devices might help to axially align components to restore patient-specific and natural tibiofemoral kinematics. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Rotator cuff tendon connections with the rotator cable.

    PubMed

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  17. Predictors of human rotation.

    PubMed

    Stochl, Jan; Croudace, Tim

    2013-01-01

    Why some humans prefer to rotate clockwise rather than anticlockwise is not well understood. This study aims to identify the predictors of the preferred rotation direction in humans. The variables hypothesised to influence rotation preference include handedness, footedness, sex, brain hemisphere lateralisation, and the Coriolis effect (which results from geospatial location on the Earth). An online questionnaire allowed us to analyse data from 1526 respondents in 97 countries. Factor analysis showed that the direction of rotation should be studied separately for local and global movements. Handedness, footedness, and the item hypothesised to measure brain hemisphere lateralisation are predictors of rotation direction for both global and local movements. Sex is a predictor of the direction of global rotation movements but not local ones, and both sexes tend to rotate clockwise. Geospatial location does not predict the preferred direction of rotation. Our study confirms previous findings concerning the influence of handedness, footedness, and sex on human rotation; our study also provides new insight into the underlying structure of human rotation movements and excludes the Coriolis effect as a predictor of rotation.

  18. Electrorotation of a metal sphere immersed in an electrolyte of finite Debye length.

    PubMed

    García-Sánchez, Pablo; Ramos, Antonio

    2015-11-01

    We theoretically study the rotation induced on a metal sphere immersed in an electrolyte and subjected to a rotating electric field. The rotation arises from the interaction of the field with the electric charges induced at the metal-electrolyte interface, i.e., the induced electrical double layer (EDL). Particle rotation is due to the torque on the induced dipole, and also from induced-charge electro-osmostic flow (ICEO). The interaction of the electric field with the induced dipole on the system gives rise to counterfield rotation, i.e., the direction opposite to the rotation of the electric field. ICEO generates co-field rotation of the sphere. For thin EDL, ICEO generates negligible rotation. For increasing size of EDL, co-field rotation appears and, in the limit of very thick EDL, it compensates the counter-field rotation induced by the electrical torque. We also report computations of the rotating fluid velocity field around the sphere.

  19. Computation of turbulent rotating channel flow with an algebraic Reynolds stress model

    NASA Technical Reports Server (NTRS)

    Warfield, M. J.; Lakshminarayana, B.

    1986-01-01

    An Algebraic Reynolds Stress Model has been implemented to modify the Kolmogorov-Prandtl eddy viscosity relation to produce an anisotropic turbulence model. The eddy viscosity relation becomes a function of the local turbulent production to dissipation ratio and local turbulence/rotation parameters. The model is used to predict fully-developed rotating channel flow over a diverse range of rotation numbers. In addition, predictions are obtained for a developing channel flow with high rotation. The predictions are compared with the experimental data available. Good predictions are achieved for mean velocity and wall shear stress over most of the rotation speeds tested. There is some prediction breakdown at high rotation (rotation number greater than .10) where the effects of the rotation on turbulence become quite complex. At high rotation and low Reynolds number, the laminarization on the trailing side represents a complex effect of rotation which is difficult to predict with the described models.

  20. Glenohumeral joint rotation range of motion in competitive swimmers.

    PubMed

    Riemann, Bryan L; Witt, Joe; Davies, George J

    2011-08-01

    Much research has examined shoulder range of motion adaptations in overhead-unilateral athletes. Based on the void examining overhead-bilateral athletes, especially competitive swimmers, we examined shoulder external rotation, isolated internal rotation, composite internal rotation, and total arc of motion range of motion of competitive swimmers. The range of motion of registered competitive swimmers (n = 144, age = 12-61 years) was compared by limb (dominant, non-dominant), sex, and age group (youth, high school, college, masters). Significantly (P < 0.05) greater dominant external rotation was observed for both men and women high school and college swimmers, youth women swimmers, and men masters swimmers compared with the non-dominant limb. The isolated internal rotation (glenohumeral rotation), composite internal rotation (glenohumeral rotation plus scapulothoracic protraction), and total arc of motion (external rotation plus composite internal rotation) of the non-dominant limb was significantly greater than that of the dominant limb by sex and age group. Youth and high school swimmers demonstrated significantly greater composite internal rotation than college and masters swimmers. Youth swimmers displayed significantly greater total arc of motion than all other age groups. These data will aid in the interpretation of shoulder range of motion values in competitive swimmers during preseason screenings, injury evaluations and post-rehabilitation programmes, with the results suggesting that differences exist in bilateral external rotation, isolated internal rotation, composite internal rotation, and total arc of motion range of motion.

  1. Effects of humeral head compression taping on the isokinetic strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis.

    PubMed

    Kim, Moon-Hwan; Oh, Jae-Seop

    2015-01-01

    [Purpose] The purpose of this study was to examine the effects of humeral head compression taping (HHCT) on the strength of the shoulder external rotator muscle in patients with rotator cuff tendinitis. [Subjects and Methods] Twenty patients with rotator cuff tendinitis were recruited. The shoulder external rotator strength was measured using a Biodex isokinetic dynamometer system. A paired t-test was performed to evaluate within-group differences in the strength of the shoulder external rotator muscle. [Results] Significantly higher shoulder external rotator peak torque and peak torque per body weight were found in the HHCT condition than in the no-taping condition. [Conclusion] HHCT may effectively increase the shoulder external rotator muscle strength in patients with rotator cuff tendinitis.

  2. Effect of classification-specific treatment on lumbopelvic motion during hip rotation in people with low back pain

    PubMed Central

    Hoffman, Shannon L; Johnson, Molly B; Zou, Dequan; Harris-Hayes, Marcie; Van Dillen, Linda R

    2010-01-01

    Increased and early lumbopelvic motion during trunk and limb movements is thought to contribute to low back pain (LBP). Therefore, reducing lumbopelvic motion could be an important component of physical therapy treatment. Our purpose was to examine the effects of classification-specific physical therapy treatment (Specific) based on the Movement System Impairment (MSI) model and non-specific treatment (Non-Specific) on lumbopelvic movement patterns during hip rotation in people with chronic LBP. We hypothesized that following treatment people in the Specific group would display decreased lumbopelvic rotation and achieve more hip rotation before lumbopelvic rotation began. We hypothesized that people in the Non-Specific group would display no change in these variables. Kinematic data collected before and after treatment for hip lateral and medial rotation in prone were analyzed. The Specific group (N=16) demonstrated significantly decreased lumbopelvic rotation and achieved greater hip rotation before the onset of lumbopelvic rotation after treatment with both hip lateral and medial rotation. The Non-Specific group (N=16) demonstrated significantly increased lumbopelvic rotation and no change in hip rotation achieved before the onset of lumbopelvic rotation. People who received treatment specific to their MSI LBP classification displayed decreased and later lumbopelvic motion with hip rotation, whereas people who received generalized non-specific treatment did not. PMID:21256073

  3. Gender differences in rotation of the shank during single-legged drop landing and its relation to rotational muscle strength of the knee.

    PubMed

    Kiriyama, Shinya; Sato, Haruhiko; Takahira, Naonobu

    2009-01-01

    Increased shank rotation during landing has been considered to be one of the factors for noncontact anterior cruciate ligament injuries in female athletes. There have been no known gender differences in rotational knee muscle strength, which is expected to inhibit exaggerated shank rotation. Women have less knee external rotator strength than do men. Lower external rotator strength is associated with increased internal shank rotation at the time of landing. Controlled laboratory study. One hundred sixty-nine healthy young subjects (81 female and 88 male; age, 17.0 +/- 1.0 years) volunteered to participate in this study. The subjects performed single-legged drop landings from a 20-cm height. Femoral and shank kinematics were measured using a 3D optoelectronic tracking system during the drop landings, and then the joint angles around the knee (flexion/extension, valgus/varus, and internal/external rotation) were calculated. The maximal isometric rotational muscle strength of the knee was measured at 30 degrees of knee flexion in a supine position using a dynamometer. The female subjects had significantly less external shank rotation strength than did the male subjects (P < .001). Female subjects also exhibited significantly greater peak shank internal rotation angles than did males during landing (P < .05). Moderate but significant association was found between the maximum shank external rotation strength and the peak shank internal rotation angle during landing (r = -0.322, P < .01). Female subjects tended to have poor shank external rotator strength. This may lead to large shank internal rotation movement during the single-legged drop landing. Improving strength training of the external rotator muscle may help decrease the rates of anterior cruciate ligament injury in female athletes.

  4. Gait in Pregnancy-related Pelvic girdle Pain: amplitudes, timing, and coordination of horizontal trunk rotations.

    PubMed

    Wu, Wen Hua; Meijer, Onno G; Bruijn, Sjoerd M; Hu, Hai; van Dieën, Jaap H; Lamoth, Claudine J C; van Royen, Barend J; Beek, Peter J

    2008-09-01

    Walking is impaired in Pregnancy-related Pelvic girdle Pain (PPP). Walking velocity is reduced, and in postpartum PPP relative phase between horizontal pelvis and thorax rotations was found to be lower at higher velocities, and rotational amplitudes tended to be larger. While attempting to confirm these findings for PPP during pregnancy, we wanted to identify underlying mechanisms. We compared gait kinematics of 12 healthy pregnant women and 12 pregnant women with PPP, focusing on the amplitudes of transverse segmental rotations, the timing and relative phase of these rotations, and the amplitude of spinal rotations. In PPP during pregnancy walking velocity was lower than in controls, and negatively correlated with fear of movement. While patients' rotational amplitudes were larger, with large inter-individual differences, spinal rotations did not differ between groups. In the patients, peak thorax rotation occurred earlier in the stride cycle at higher velocities, and relative phase was lower. The earlier results on postpartum PPP were confirmed for PPP during pregnancy. Spinal rotations remained unaffected, while at higher velocities the peak of thorax rotations occurred earlier in the stride cycle. The latter change may serve to avoid excessive spine rotations caused by the larger segmental rotations.

  5. Gait in Pregnancy-related Pelvic girdle Pain: amplitudes, timing, and coordination of horizontal trunk rotations

    PubMed Central

    Wu, Wen Hua; Bruijn, Sjoerd M.; Hu, Hai; van Dieën, Jaap H.; Lamoth, Claudine J. C.; van Royen, Barend J.; Beek, Peter J.

    2008-01-01

    Walking is impaired in Pregnancy-related Pelvic girdle Pain (PPP). Walking velocity is reduced, and in postpartum PPP relative phase between horizontal pelvis and thorax rotations was found to be lower at higher velocities, and rotational amplitudes tended to be larger. While attempting to confirm these findings for PPP during pregnancy, we wanted to identify underlying mechanisms. We compared gait kinematics of 12 healthy pregnant women and 12 pregnant women with PPP, focusing on the amplitudes of transverse segmental rotations, the timing and relative phase of these rotations, and the amplitude of spinal rotations. In PPP during pregnancy walking velocity was lower than in controls, and negatively correlated with fear of movement. While patients’ rotational amplitudes were larger, with large inter-individual differences, spinal rotations did not differ between groups. In the patients, peak thorax rotation occurred earlier in the stride cycle at higher velocities, and relative phase was lower. The earlier results on postpartum PPP were confirmed for PPP during pregnancy. Spinal rotations remained unaffected, while at higher velocities the peak of thorax rotations occurred earlier in the stride cycle. The latter change may serve to avoid excessive spine rotations caused by the larger segmental rotations. PMID:18661160

  6. The influence of patient factors on femoral rotation after total hip arthroplasty.

    PubMed

    Tezuka, Taro; Inaba, Yutaka; Kobayashi, Naomi; Choe, Hyonmin; Higashihira, Syota; Saito, Tomoyuki

    2018-06-09

    A postoperative change in femoral rotation following total hip arthroplasty (THA) might be the cause of dislocation due to the change in combined anteversion. However, very few studies have evaluated the femoral rotation angle following THA, or the factors that influence femoral rotation. We aimed to evaluate changes in femoral rotation after THA, and to investigate preoperative patient factors that influence femoral rotation after THA. This study involved 211 hips treated with primary THA. We used computed tomography to measure the femoral rotation angle before and one week after THA. In addition, multiple regression analysis was performed to evaluate preoperative patient factors that could influence femoral rotation after THA. The femoral rotation angle was 0.2 ± 14° externally before surgery and 4.4 ± 12° internally after surgery (p < 0.001). Multiple regression analysis revealed that sex (β = 0.19; p = 0.003), age (β = 0.15; p = 0.017), preoperative anatomical femoral anteversion (β = - 0.25; p = 0.002), and preoperative femoral rotation angle (β = 0.36; p < 0.001) were significantly associated with the postoperative femoral rotation angle. The final model of the regression formula was described by the following equation: [postoperative femoral rotation angle = 5.41 × sex (female: 0, male: 1) + 0.15 × age - 0.22 × preoperative anatomical femoral anteversion + 0.33 × preoperative femoral rotation angle - 10.1]. The current study showed the mean internal change of 4.6° in the femoral rotation angle one week after THA. Sex, age, preoperative anatomical femoral anteversion and preoperative femoral rotation were associated with postoperative femoral rotation. The patients who were male, older, and who exhibited lesser preoperative anatomical femoral anteversion or greater preoperative femoral rotation angles, tended to demonstrate an externally rotated femur after THA. Conversely, patients who were female, younger, and who exhibited greater preoperative anatomical femoral anteversion or lesser preoperative femoral rotation angles, tended to demonstrate an internal rotation of the femur after THA.

  7. On the Behavior of Velocity Fluctuations in Rapidly Rotating Flows

    NASA Technical Reports Server (NTRS)

    Girimaji, S. S.; Ristorcelli, J. R.

    1997-01-01

    The behavior of velocity fluctuations subjected to rapid rotation is examined. The rapid rotation considered is any arbitrary combination of two basic forms of rotation, reference frame rotation and mean flow rotation. It is recognized that the two types of rotating flows differ in the manner in which the fluctuating fields are advected. The first category is comprised of flows in rotating systems of which synoptic scale geophysical flows are a good example. In this class of flows the fluctuating velocity field advects and rotates with the mean flow. In the rapid rotation limit, the Taylor-Proudman theorem describes the behavior of this class of fluctuations. Velocity fluctuations that are advected without rotation by the mean flow constitute the second category which includes vortical flows of aerodynamic interest. The Taylor-Proudman theorem is not pertinent to I his class flows and a new result appropriate to this second category of fluctuations is derived. The present development demonstrates that the fluctuating velocity fields are rendered two-dimensional and horizontally non-divergent in the limit of any large combination of reference frame rotation and mean-flow rotation. The concommitant 'geostrophic' balance of the momentum equation is, however, dependent upon the form of rapid rotation. It is also demonstrated that the evolution equations of a two-dimensional fluctuating velocity fields are frame-indifferent with any imposed mean-flow rotation. The analyses and results of this paper highlight many fundamental aspects of rotating flows and have important consequences for their turbulence closures in inertial and non-inertial frames.

  8. The Optimal Forest Rotation: A Discussion and Annotated Bibliography

    Treesearch

    David H. Newman

    1988-01-01

    The literature contains six different criteria of the optimal forest rotation: (1) maximum single-rotation physical yield, (2) maximum single-rotation annual yield, (3) maximum single-rotation discounted net revenues, (4) maximum discounted net revenues from an infinite series of rotations, (5) maximum annual net revenues, and (6) maximum internal rate of return. First...

  9. Dependence of locked mode behavior on frequency and polarity of a rotating external magnetic perturbation

    NASA Astrophysics Data System (ADS)

    Inoue, S.; Shiraishi, J.; Takechi, M.; Matsunaga, G.; Isayama, A.; Hayashi, N.; Ide, S.

    2018-02-01

    Active control and stabilization of locked modes (LM) via rotating external magnetic perturbations are numerically investigated under a realistic low resistivity condition. To explore plasma responses to rotating and/or static external magnetic perturbations, we have developed a resistive magnetohydrodynamic code ‘AEOLUS-IT’. By using AEOLUS-IT, dependencies of mode behavior on frequency and polarity of the rotating magnetic perturbation are successfully clarified. Here, the rotational direction of the rotating magnetic perturbation to the equilibrium plasma rotation in the laboratory frame is referred to as ‘polarity’. The rotating magnetic perturbation acts on the background rotating plasma in the presence of a static field. Under such circumstances, there exist bifurcated states of the background rotating plasma, which should be taken into account when studying the dependence of the mode behavior on the rotating magnetic perturbation. It is found that there exist an optimum frequency and polarity of the rotating magnetic perturbation to control the LM, and that the LM is effectively stabilized by a co-polarity magnetic perturbation in comparison with a counter-polarity one.

  10. Inelastic electron tunneling mediated by a molecular quantum rotator

    NASA Astrophysics Data System (ADS)

    Sugimoto, Toshiki; Kunisada, Yuji; Fukutani, Katsuyuki

    2017-12-01

    Inelastic electron tunneling (IET) accompanying nuclear motion is not only of fundamental physical interest but also has strong impacts on chemical and biological processes in nature. Although excitation of rotational motion plays an important role in enhancing electric conductance at a low bias, the mechanism of rotational excitation remains veiled. Here, we present a basic theoretical framework of IET that explicitly takes into consideration quantum angular momentum, focusing on a molecular H2 rotator trapped in a nanocavity between two metallic electrodes as a model system. It is shown that orientationally anisotropic electrode-rotator coupling is the origin of angular-momentum exchange between the electron and molecule; we found that the anisotropic coupling imposes rigorous selection rules in rotational excitation. In addition, rotational symmetry breaking induced by the anisotropic potential lifts the degeneracy of the energy level of the degenerated rotational state of the quantum rotator and tunes the threshold bias voltage that triggers rotational IET. Our theoretical results provide a paradigm for physical understanding of the rotational IET process and spectroscopy, as well as molecular-level design of electron-rotation coupling in nanoelectronics.

  11. Rotational seismology

    USGS Publications Warehouse

    Lee, William H K.

    2016-01-01

    Rotational seismology is an emerging study of all aspects of rotational motions induced by earthquakes, explosions, and ambient vibrations. It is of interest to several disciplines, including seismology, earthquake engineering, geodesy, and earth-based detection of Einstein’s gravitation waves.Rotational effects of seismic waves, together with rotations caused by soil–structure interaction, have been observed for centuries (e.g., rotated chimneys, monuments, and tombstones). Figure 1a shows the rotated monument to George Inglis observed after the 1897 Great Shillong earthquake. This monument had the form of an obelisk rising over 19 metres high from a 4 metre base. During the earthquake, the top part broke off and the remnant of some 6 metres rotated about 15° relative to the base. The study of rotational seismology began only recently when sensitive rotational sensors became available due to advances in aeronautical and astronomical instrumentations.

  12. Optical rotation compensation for a holographic 3D display with a 360 degree horizontal viewing zone.

    PubMed

    Sando, Yusuke; Barada, Daisuke; Yatagai, Toyohiko

    2016-10-20

    A method for a continuous optical rotation compensation in a time-division-based holographic three-dimensional (3D) display with a rotating mirror is presented. Since the coordinate system of wavefronts after the mirror reflection rotates about the optical axis along with the rotation angle, compensation or cancellation is absolutely necessary to fix the reconstructed 3D object. In this study, we address this problem by introducing an optical image rotator based on a right-angle prism that rotates synchronously with the rotating mirror. The optical and continuous compensation reduces the occurrence of duplicate images, which leads to the improvement of the quality of reconstructed images. The effect of the optical rotation compensation is experimentally verified and a demonstration of holographic 3D display with the optical rotation compensation is presented.

  13. Relative mobility of the pelvis and spine during trunk axial rotation in chronic low back pain patients: A case-control study

    PubMed Central

    Ibuki, Satoko; Ichihashi, Noriaki

    2017-01-01

    Background Trunk axial rotation is a risk factor for chronic low back pain (CLBP). The characteristics of rotational mobility in the pelvis and spine among CLBP patients are not fully understood. Purpose The purpose of this study was to examine three-dimensional kinematic changes, and to compare the differences of rotational mobility and coupled motion, in patients with and without CLBP. Methods Fifteen patients with CLBP and 15 age and sex matched healthy subjects participated in this study. Each subject performed trunk rotation to maximum range of motion (ROM) in a standing position. The kinematics data was collected using a three-dimensional motion analysis system. The outcomes measured were the rotational ROM and the spine/pelvis ratio (SPR) in transvers plane at both maximum and 50% rotation position. The coupled angles in sagittal and frontal planes were also measured. Results No significant differences in rotational ROM of the thorax, pelvis, and spine were observed between two groups at maximum rotation position. However, there was a significant interaction between groups and rotational ROM of pelvis and spine (F = 4.57, p = 0.04), and the SPR in CLBP patients was significantly greater than that of the healthy subjects (CLBP; 0.50 ± 0.10 Control; 0.41 ± 0.12, p = 0.04). The results at 50% rotation position were similar to that at maximum rotation. This indicates a relative increase in spinal rotation in the CLBP patients during trunk rotation. Moreover, the CLBP patients exhibited a significantly higher anterior tilt of the pelvis and extension of the spine in the sagittal plane coupled with rotation. Conclusions CLBP patients had relative hyper rotational mobility of the spine as well as excessive spinal extension coupled with trunk rotation. These results suggest that uncoordinated trunk rotation might be a functional failure associated with CLBP. PMID:29040298

  14. Relative mobility of the pelvis and spine during trunk axial rotation in chronic low back pain patients: A case-control study.

    PubMed

    Taniguchi, Masashi; Tateuchi, Hiroshige; Ibuki, Satoko; Ichihashi, Noriaki

    2017-01-01

    Trunk axial rotation is a risk factor for chronic low back pain (CLBP). The characteristics of rotational mobility in the pelvis and spine among CLBP patients are not fully understood. The purpose of this study was to examine three-dimensional kinematic changes, and to compare the differences of rotational mobility and coupled motion, in patients with and without CLBP. Fifteen patients with CLBP and 15 age and sex matched healthy subjects participated in this study. Each subject performed trunk rotation to maximum range of motion (ROM) in a standing position. The kinematics data was collected using a three-dimensional motion analysis system. The outcomes measured were the rotational ROM and the spine/pelvis ratio (SPR) in transvers plane at both maximum and 50% rotation position. The coupled angles in sagittal and frontal planes were also measured. No significant differences in rotational ROM of the thorax, pelvis, and spine were observed between two groups at maximum rotation position. However, there was a significant interaction between groups and rotational ROM of pelvis and spine (F = 4.57, p = 0.04), and the SPR in CLBP patients was significantly greater than that of the healthy subjects (CLBP; 0.50 ± 0.10 Control; 0.41 ± 0.12, p = 0.04). The results at 50% rotation position were similar to that at maximum rotation. This indicates a relative increase in spinal rotation in the CLBP patients during trunk rotation. Moreover, the CLBP patients exhibited a significantly higher anterior tilt of the pelvis and extension of the spine in the sagittal plane coupled with rotation. CLBP patients had relative hyper rotational mobility of the spine as well as excessive spinal extension coupled with trunk rotation. These results suggest that uncoordinated trunk rotation might be a functional failure associated with CLBP.

  15. Effect of rotation on a rotating hot-wire sensor

    NASA Technical Reports Server (NTRS)

    Hah, C.; Lakshminarayana, B.

    1978-01-01

    An investigation was conducted to discern the effects of centrifugal and Coriolis forces on a rotating hot-wire. The probe was calibrated in a wind tunnel as well as in a rotating mode. The effect of rotation was found to be negligibly small. A small change in cold resistance (1.5%) was observed in the rotating wire. The rotation seems to have a negligible effect on the fluid mechanics, heat transfer and material characteristics of the wire. This is a significant conclusion in view of the potential application of the hot-wire probe in a rotating passage (such as turbomachinery).

  16. Quantum measurement of a rapidly rotating spin qubit in diamond.

    PubMed

    Wood, Alexander A; Lilette, Emmanuel; Fein, Yaakov Y; Tomek, Nikolas; McGuinness, Liam P; Hollenberg, Lloyd C L; Scholten, Robert E; Martin, Andy M

    2018-05-01

    A controlled qubit in a rotating frame opens new opportunities to probe fundamental quantum physics, such as geometric phases in physically rotating frames, and can potentially enhance detection of magnetic fields. Realizing a single qubit that can be measured and controlled during physical rotation is experimentally challenging. We demonstrate quantum control of a single nitrogen-vacancy (NV) center within a diamond rotated at 200,000 rpm, a rotational period comparable to the NV spin coherence time T 2 . We stroboscopically image individual NV centers that execute rapid circular motion in addition to rotation and demonstrate preparation, control, and readout of the qubit quantum state with lasers and microwaves. Using spin-echo interferometry of the rotating qubit, we are able to detect modulation of the NV Zeeman shift arising from the rotating NV axis and an external DC magnetic field. Our work establishes single NV qubits in diamond as quantum sensors in the physically rotating frame and paves the way for the realization of single-qubit diamond-based rotation sensors.

  17. Quantum measurement of a rapidly rotating spin qubit in diamond

    PubMed Central

    Fein, Yaakov Y.; Hollenberg, Lloyd C. L.; Scholten, Robert E.

    2018-01-01

    A controlled qubit in a rotating frame opens new opportunities to probe fundamental quantum physics, such as geometric phases in physically rotating frames, and can potentially enhance detection of magnetic fields. Realizing a single qubit that can be measured and controlled during physical rotation is experimentally challenging. We demonstrate quantum control of a single nitrogen-vacancy (NV) center within a diamond rotated at 200,000 rpm, a rotational period comparable to the NV spin coherence time T2. We stroboscopically image individual NV centers that execute rapid circular motion in addition to rotation and demonstrate preparation, control, and readout of the qubit quantum state with lasers and microwaves. Using spin-echo interferometry of the rotating qubit, we are able to detect modulation of the NV Zeeman shift arising from the rotating NV axis and an external DC magnetic field. Our work establishes single NV qubits in diamond as quantum sensors in the physically rotating frame and paves the way for the realization of single-qubit diamond-based rotation sensors. PMID:29736417

  18. Behavior of a Light Solid in a Rotating Horizontal Cylinder with Liquid Under Vibration

    NASA Astrophysics Data System (ADS)

    Karpunin, I. E.; Kozlova, A. N.; Kozlov, N. V.

    2018-06-01

    Dynamics of a cylindrical body in a rotating cavity is experimentally studied under transversal translational vibrations of the cavity rotation axis. Experiments are run at high rotation rate, when under the action of centrifugal force the body shifts to the rotation axis (the centrifuged state). In the absence of vibrations, the lagging rotation of the body is observed, due to the body radial shift from the axis of rotation caused by gravity. The body average rotation regime depends on the cavity rotation rate. The vibrations lead to the excitation of different regimes of body differential rotation (leading or lagging) associated with the excitation of its inertial oscillations. The dependence of the differential speed of the body rotation on the vibration frequency is investigated. The body dynamics has a complex character depending on the dimensionless vibration frequency. The analysis of body oscillation trajectory revealed that the body oscillatory motion consists of several modes, which contribute to the averaged dynamics of the body and the flows in the cavity.

  19. Rotating superconductor magnet for producing rotating lobed magnetic field lines

    DOEpatents

    Hilal, Sadek K.; Sampson, William B.; Leonard, Edward F.

    1978-01-01

    This invention provides a rotating superconductor magnet for producing a rotating lobed magnetic field, comprising a cryostat; a superconducting magnet in the cryostat having a collar for producing a lobed magnetic field having oppositely directed adjacent field lines; rotatable support means for selectively rotating the superconductor magnet; and means for energizing the superconductor magnet.

  20. Apparatus and method for materials processing utilizing a rotating magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muralidharan, Govindarajan; Angelini, Joseph A.; Murphy, Bart L.

    An apparatus for materials processing utilizing a rotating magnetic field comprises a platform for supporting a specimen, and a plurality of magnets underlying the platform. The plurality of magnets are configured for rotation about an axis of rotation intersecting the platform. A heat source is disposed above the platform for heating the specimen during the rotation of the plurality of magnets. A method for materials processing utilizing a rotating magnetic field comprises providing a specimen on a platform overlying a plurality of magnets; rotating the plurality of magnets about an axis of rotation intersecting the platform, thereby applying a rotatingmore » magnetic field to the specimen; and, while rotating the plurality of magnets, heating the specimen to a desired temperature.« less

  1. Rotational Seismology: AGU Session, Working Group, and Website

    USGS Publications Warehouse

    Lee, William H.K.; Igel, Heiner; Todorovska, Maria I.; Evans, John R.

    2007-01-01

    Introduction Although effects of rotational motions due to earthquakes have long been observed (e. g., Mallet, 1862), nevertheless Richter (1958, p. 213) stated that: 'Perfectly general motion would also involve rotations about three perpendicular axes, and three more instruments for these. Theory indicates, and observation confirms, that such rotations are negligible.' However, Richter provided no references for this claim. Seismology is based primarily on the observation and modeling of three-component translational ground motions. Nevertheless, theoretical seismologists (e.g., Aki and Richards, 1980, 2002) have argued for decades that the rotational part of ground motions should also be recorded. It is well known that standard seismometers are quite sensitive to rotations and therefore subject to rotation-induced errors. The paucity of observations of rotational motions is mainly the result of a lack, until recently, of affordable rotational sensors of sufficient resolution. Nevertheless, in the past decade, a number of authors have reported direct observations of rotational motions and rotations inferred from rigid-body rotations in short baseline accelerometer arrays, creating a burgeoning library of rotational data. For example, ring laser gyros in Germany and New Zealand have led to the first significant and consistent observations of rotational motions from distant earthquakes (Igel et al., 2005, 2007). A monograph on Earthquake Source Asymmetry, Structural Media and Rotation Effects was published recently as well by Teisseyre et al. (2006). Measurement of rotational motions has implications for: (1) recovering the complete ground-displacement history from seismometer recordings; (2) further constraining earthquake rupture properties; (3) extracting information about subsurface properties; and (4) providing additional ground motion information to earthquake engineers for seismic design. A special session on Rotational Motions in Seismology was convened by H. Igel, W.H.K. Lee, and M. Todorovska during the 2006 AGU Fall Meeting. The goal of this session was to discuss rotational sensors, observations, modeling, theoretical aspects, and potential applications of rotational ground motions. The session was accompanied by the inauguration of an International Working Group on Rotational Seismology (IWGoRS) which aims to promote investigations of all aspects of rotational motions in seismology and their implications for related fields such as earthquake engineering, geodesy, strong-motion seismology, and tectonics, as well as to share experience, data, software, and results in an open Web-based environment. The primary goal of this article is to make the Earth Science Community aware of the emergence of the field of rotational seismology.

  2. Improper trunk rotation sequence is associated with increased maximal shoulder external rotation angle and shoulder joint force in high school baseball pitchers.

    PubMed

    Oyama, Sakiko; Yu, Bing; Blackburn, J Troy; Padua, Darin A; Li, Li; Myers, Joseph B

    2014-09-01

    In a properly coordinated throwing motion, peak pelvic rotation velocity is reached before peak upper torso rotation velocity, so that angular momentum can be transferred effectively from the proximal (pelvis) to distal (upper torso) segment. However, the effects of trunk rotation sequence on pitching biomechanics and performance have not been investigated. The aim of this study was to investigate the effects of trunk rotation sequence on ball speed and on upper extremity biomechanics that are linked to injuries in high school baseball pitchers. The hypothesis was that pitchers with improper trunk rotation sequence would demonstrate lower ball velocity and greater stress to the joint. Descriptive laboratory study. Three-dimensional pitching kinematics data were captured from 72 high school pitchers. Subjects were considered to have proper or improper trunk rotation sequences when the peak pelvic rotation velocity was reached either before or after the peak upper torso rotation velocity beyond the margin of error (±3.7% of the time from stride-foot contact to ball release). Maximal shoulder external rotation angle, elbow extension angle at ball release, peak shoulder proximal force, shoulder internal rotation moment, and elbow varus moment were compared between groups using independent t tests (α < 0.05). Pitchers with improper trunk rotation sequences (n = 33) demonstrated greater maximal shoulder external rotation angle (mean difference, 7.2° ± 2.9°, P = .016) and greater shoulder proximal force (mean difference, 9.2% ± 3.9% body weight, P = .021) compared with those with proper trunk rotation sequences (n = 22). No other variables differed significantly different between groups. High school baseball pitchers who demonstrated improper trunk rotation sequences demonstrated greater maximal shoulder external rotation angle and shoulder proximal force compared with pitchers with proper trunk rotation sequences. Improper sequencing of the trunk and torso alter upper extremity joint loading in ways that may influence injury risk. As such, exercises that reinforce the use of a proper trunk rotation sequence during the pitching motion may reduce the stress placed on the structures around the shoulder joint and lead to the prevention of injuries. © 2014 The Author(s).

  3. Visual information processing in the lion-tailed macaque (Macaca silenus): mental rotation or rotational invariance?

    PubMed

    Burmann, Britta; Dehnhardt, Guido; Mauck, Björn

    2005-01-01

    Mental rotation is a widely accepted concept indicating an image-like mental representation of visual information and an analogue mode of information processing in certain visuospatial tasks. In the task of discriminating between image and mirror-image of rotated figures, human reaction times increase with the angular disparity between the figures. In animals, tests of this kind yield inconsistent results. Pigeons were found to use a time-independent rotational invariance, possibly indicating a non-analogue information processing system that evolved in response to the horizontal plane of reference birds perceive during flight. Despite similar ecological demands concerning the visual reference plane, a sea lion was found to use mental rotation in similar tasks, but its processing speed while rotating three-dimensional stimuli seemed to depend on the axis of rotation in a different way than found for humans in similar tasks. If ecological demands influence the way information processing systems evolve, hominids might have secondarily lost the ability of rotational invariance while retreating from arboreal living and evolving an upright gait in which the vertical reference plane is more important. We therefore conducted mental rotation experiments with an arboreal living primate species, the lion-tailed macaque. Performing a two-alternative matching-to-sample procedure, the animal had to decide between rotated figures representing image and mirror-image of a previously shown upright sample. Although non-rotated stimuli were recognized faster than rotated ones, the animal's mean reaction times did not clearly increase with the angle of rotation. These results are inconsistent with the mental rotation concept but also cannot be explained assuming a mere rotational invariance. Our study thus seems to support the idea of information processing systems evolving gradually in response to specific ecological demands.

  4. Anatomical glenohumeral internal rotation deficit and symmetric rotational strength in male and female young beach volleyball players.

    PubMed

    Saccol, Michele Forgiarini; Almeida, Gabriel Peixoto Leão; de Souza, Vivian Lima

    2016-08-01

    Beach volleyball is a sport with a high demand of shoulder structures that may lead to adaptations in range of motion (ROM) and strength like in other overhead sports. Despite of these possible alterations, no study evaluated the shoulder adaptations in young beach volleyball athletes. The aim of this study was to compare the bilateral ROM and rotation strength in the shoulders of young beach volleyball players. Goniometric passive shoulder ROM of motion and isometric rotational strength were evaluated in 19 male and 14 female asymptomatic athletes. External and internal ROM, total rotation motion, glenohumeral internal rotation deficit (GIRD), external rotation and internal rotation strength, bilateral deficits and external rotation to internal rotation ratio were measured. The statistical analysis included paired Student's t-test and analysis of variance with repeated measures. Significantly lower dominant GIRD was found in both groups (p<0.05), but only 6 athletes presented pathological GIRD. For strength variables, no significant differences for external or internal rotation were evident. Young beach volleyball athletes present symmetric rotational strength and shoulder ROM rotational adaptations that can be considered as anatomical. These results indicate that young practitioners of beach volleyball are subject to moderate adaptations compared to those reported for other overhead sports. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. An immediate effect of axial neck rotation training with real time visual feedback using a smartphone inclinometer on improvement in axial neck rotation function.

    PubMed

    Park, Kyue-Nam; Kwon, Oh-Yun; Kim, Si-Hyun; Jeon, In-Cheol

    2017-03-01

    The purpose of this study was to compare the immediate effects of axial neck rotation training (Axi-NRT) with and without real-time visual feedback (VF) using a smartphone inclinometer on the range of motion (ROM) for axial neck rotation and the onset of compensatory neck lateral bending and extension during active neck rotation. Twenty participants with restricted ROM for neck rotation but no neck pain (21.1 ± 1.6 years and 8 males, 12 females) were recruited for Axi-NRT with VF, and twenty age- and gender-matched participants with restricted ROM for neck rotation were recruited for Axi-NRT without VF. Changes in ROM for neck rotation and the onset time of compensatory neck movement during active neck rotation were measured using an electromagnetic tracking system. Axi-NRT with VF was more effective in increasing ROM for neck rotation and decreasing and delaying the onset of compensatory neck movements during active neck rotation compared with Axi-NRT without VF. Repeated Axi-NRT using VF is useful to educate participants in maintaining the axis of the cervical spine and to increase ROM for axial neck rotation with less compensatory neck motion in participants with a restricted range of neck rotations.

  6. Studies on dynamic behavior of rotating mirrors

    NASA Astrophysics Data System (ADS)

    Li, Jingzhen; Sun, Fengshan; Gong, Xiangdong; Huang, Hongbin; Tian, Jie

    2005-02-01

    A rotating mirror is a kernel unit in a Miller-type high speed camera, which is both as an imaging element in optical path and as an element to implement ultrahigh speed photography. According to Schardin"s Principle, information capacity of an ultrahigh speed camera with rotating mirror depends on primary wavelength of lighting used by the camera and limit linear velocity on edge of the rotating-mirror: the latter is related to material (including specifications in technology), cross-section shape and lateral structure of rotating mirror. In this manuscript dynamic behavior of high strength aluminium alloy rotating mirrors is studied, from which it is preliminarily shown that an aluminium alloy rotating mirror can be absolutely used as replacement for a steel rotating-mirror or a titanium alloy rotating-mirror in framing photographic systems, and it could be also used as a substitute for a beryllium rotating-mirror in streak photographic systems.

  7. Contribution of calcaneal and leg segment rotations to ankle joint dorsiflexion in a weight-bearing task.

    PubMed

    Chizewski, Michael G; Chiu, Loren Z F

    2012-05-01

    Joint angle is the relative rotation between two segments where one is a reference and assumed to be non-moving. However, rotation of the reference segment will influence the system's spatial orientation and joint angle. The purpose of this investigation was to determine the contribution of leg and calcaneal rotations to ankle rotation in a weight-bearing task. Forty-eight individuals performed partial squats recorded using a 3D motion capture system. Markers on the calcaneus and leg were used to model leg and calcaneal segment, and ankle joint rotations. Multiple linear regression was used to determine the contribution of leg and calcaneal segment rotations to ankle joint dorsiflexion. Regression models for left (R(2)=0.97) and right (R(2)=0.97) ankle dorsiflexion were significant. Sagittal plane leg rotation had a positive influence (left: β=1.411; right: β=1.418) while sagittal plane calcaneal rotation had a negative influence (left: β=-0.573; right: β=-0.650) on ankle dorsiflexion. Sagittal plane rotations of the leg and calcaneus were positively correlated (left: r=0.84, P<0.001; right: r=0.80, P<0.001). During a partial squat, the calcaneus rotates forward. Simultaneous forward calcaneal rotation with ankle dorsiflexion reduces total ankle dorsiflexion angle. Rear foot posture is reoriented during a partial squat, allowing greater leg rotation in the sagittal plane. Segment rotations may provide greater insight into movement mechanics that cannot be explained via joint rotations alone. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. The Role of the Away Rotation in Otolaryngology Residency.

    PubMed

    Villwock, Jennifer A; Hamill, Chelsea S; Ryan, Jesse T; Nicholas, Brian D

    2017-06-01

    Objective To determine the availability and purpose of away rotations during otolaryngology residency. Study Design Cross-sectional survey. Setting Otolaryngology residency programs. Subjects and Methods An anonymous web-based survey was sent to 98 allopathic otolaryngology training program directors, of which 38 programs responded. Fisher exact tests and nonparametric correlations were used to determine statistically significant differences among various strata of programs. A P value of <.05 was considered statistically significant. Results Thirty-nine percent (n = 38) of queried programs responded. Mandatory away rotations and elective away rotations were both present in 6 of 38 programs (16%). Neither number of faculty ( P = .119) nor residents ( P = .88) was predictive of away rotation. Away rotations were typically >151 miles from the home institution and typically used to address deficiencies in clinical exposure (67%) or case volume (50%). Participants of mandatory away rotations were universally provided housing, with other consideration such as stipend (33%), relocation allowance (33%), or food allowance (16%) sometimes offered. In contrast to mandatory rotations, half of elective rotations were to obtain a unique international mission trip experience. Nearly one-third of surveyed program directors (29%) would consider adding an away rotation to their curriculum in the next 3 years. Conclusions Mandatory and elective away rotations play a role in a small, but not insignificant, number of training programs. The rationale for these rotations is variable. Given that nearly one-third of program directors would consider adding an away rotation in the near future, further research into components of a meaningful away rotation and how to optimize the away rotation experience is warranted.

  9. Cell envelopes of chemotaxis mutants of Escherichia coli rotate their flagella counterclockwise.

    PubMed Central

    Szupica, C J; Adler, J

    1985-01-01

    Flagella rotated exclusively counterclockwise in Escherichia coli cell envelopes prepared from wild-type cells, whose flagella rotated both clockwise and counterclockwise, from mutants rotating their flagella counterclockwise only, and even from mutants rotating their flagella primarily clockwise. Some factor needed for clockwise flagellar rotation appeared to be missing or defective in the cell envelopes. PMID:3884599

  10. Lattice QCD in rotating frames.

    PubMed

    Yamamoto, Arata; Hirono, Yuji

    2013-08-23

    We formulate lattice QCD in rotating frames to study the physics of QCD matter under rotation. We construct the lattice QCD action with the rotational metric and apply it to the Monte Carlo simulation. As the first application, we calculate the angular momenta of gluons and quarks in the rotating QCD vacuum. This new framework is useful to analyze various rotation-related phenomena in QCD.

  11. Dynactin-dependent cortical dynein and spherical spindle shape correlate temporally with meiotic spindle rotation in Caenorhabditis elegans

    PubMed Central

    Crowder, Marina E.; Flynn, Jonathan R.; McNally, Karen P.; Cortes, Daniel B.; Price, Kari L.; Kuehnert, Paul A.; Panzica, Michelle T.; Andaya, Armann; Leary, Julie A.; McNally, Francis J.

    2015-01-01

    Oocyte meiotic spindles orient with one pole juxtaposed to the cortex to facilitate extrusion of chromosomes into polar bodies. In Caenorhabditis elegans, these acentriolar spindles initially orient parallel to the cortex and then rotate to the perpendicular orientation. To understand the mechanism of spindle rotation, we characterized events that correlated temporally with rotation, including shortening of the spindle in the pole-to pole axis, which resulted in a nearly spherical spindle at rotation. By analyzing large spindles of polyploid C. elegans and a related nematode species, we found that spindle rotation initiated at a defined spherical shape rather than at a defined spindle length. In addition, dynein accumulated on the cortex just before rotation, and microtubules grew from the spindle with plus ends outward during rotation. Dynactin depletion prevented accumulation of dynein on the cortex and prevented spindle rotation independently of effects on spindle shape. These results support a cortical pulling model in which spindle shape might facilitate rotation because a sphere can rotate without deforming the adjacent elastic cytoplasm. We also present evidence that activation of spindle rotation is promoted by dephosphorylation of the basic domain of p150 dynactin. PMID:26133383

  12. Difference in perception of angular displacement according to applied waveforms.

    PubMed

    Kushiro, Keisuke; Goto, Fumiyuki

    2013-05-01

    This study shows that the differences in the waveforms of angular rotation affect the perception and memory of angular displacement. During daily life, when we turn our head during various activities, our brain calculates how much angular displacement our head has undergone. However, how we obtain an accurate estimation of this angular displacement remains unclarified. This study aims to clarify this issue by investigating the perception and memory of passive rotation for three different waveforms of angular velocity rotation (sinusoidal (sine), triangle, and step). Thirteen healthy young subjects sitting on a servo-controlled chair were passively rotated at 60° or 120° about the earth-vertical axis by using one of these three angular velocity waveforms. They then attempted to reproduce the rotation angle by rotating the chair in the same direction in which they had been passively rotated using a handheld controller. The gain (reproduced angle/passively rotated angle) was calculated and used for the evaluation of the perception and memory of angular rotation. The gain for step rotation was larger than that for sine and triangle rotations, with statistical significance. This confirms that the difference in the waveforms of angular rotation affects the perception and memory of angular displacement.

  13. Judging sound rotation when listeners and sounds rotate: Sound source localization is a multisystem process.

    PubMed

    Yost, William A; Zhong, Xuan; Najam, Anbar

    2015-11-01

    In four experiments listeners were rotated or were stationary. Sounds came from a stationary loudspeaker or rotated from loudspeaker to loudspeaker around an azimuth array. When either sounds or listeners rotate the auditory cues used for sound source localization change, but in the everyday world listeners perceive sound rotation only when sounds rotate not when listeners rotate. In the everyday world sound source locations are referenced to positions in the environment (a world-centric reference system). The auditory cues for sound source location indicate locations relative to the head (a head-centric reference system), not locations relative to the world. This paper deals with a general hypothesis that the world-centric location of sound sources requires the auditory system to have information about auditory cues used for sound source location and cues about head position. The use of visual and vestibular information in determining rotating head position in sound rotation perception was investigated. The experiments show that sound rotation perception when sources and listeners rotate was based on acoustic, visual, and, perhaps, vestibular information. The findings are consistent with the general hypotheses and suggest that sound source localization is not based just on acoustics. It is a multisystem process.

  14. Composition of Muscle Fiber Types in Rat Rotator Cuff Muscles.

    PubMed

    Rui, Yongjun; Pan, Feng; Mi, Jingyi

    2016-10-01

    The rat is a suitable model to study human rotator cuff pathology owing to the similarities in morphological anatomy structure. However, few studies have reported the composition muscle fiber types of rotator cuff muscles in the rat. In this study, the myosin heavy chain (MyHC) isoforms were stained by immunofluorescence to show the muscle fiber types composition and distribution in rotator cuff muscles of the rat. It was found that rotator cuff muscles in the rat were of mixed fiber type composition. The majority of rotator cuff fibers labeled positively for MyHCII. Moreover, the rat rotator cuff muscles contained hybrid fibers. So, compared with human rotator cuff muscles composed partly of slow-twitch fibers, the majority of fast-twitch fibers in rat rotator cuff muscles should be considered when the rat model study focus on the pathological process of rotator cuff muscles after injury. Gaining greater insight into muscle fiber types in rotator cuff muscles of the rat may contribute to elucidate the mechanism of pathological change in rotator cuff muscles-related diseases. Anat Rec, 299:1397-1401, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Limits on radial differential rotation in Sun-like stars from parametric fits to oscillation power spectra

    NASA Astrophysics Data System (ADS)

    Nielsen, M. B.; Schunker, H.; Gizon, L.; Schou, J.; Ball, W. H.

    2017-06-01

    Context. Rotational shear in Sun-like stars is thought to be an important ingredient in models of stellar dynamos. Thanks to helioseismology, rotation in the Sun is characterized well, but the interior rotation profiles of other Sun-like stars are not so well constrained. Until recently, measurements of rotation in Sun-like stars have focused on the mean rotation, but little progress has been made on measuring or even placing limits on differential rotation. Aims: Using asteroseismic measurements of rotation we aim to constrain the radial shear in five Sun-like stars observed by the NASA Kepler mission: KIC 004914923, KIC 005184732, KIC 006116048, KIC 006933899, and KIC 010963065. Methods: We used stellar structure models for these five stars from previous works. These models provide the mass density, mode eigenfunctions, and the convection zone depth, which we used to compute the sensitivity kernels for the rotational frequency splitting of the modes. We used these kernels as weights in a parametric model of the stellar rotation profile of each star, where we allowed different rotation rates for the radiative interior and the convective envelope. This parametric model was incorporated into a fit to the oscillation power spectrum of each of the five Kepler stars. This fit included a prior on the rotation of the envelope, estimated from the rotation of surface magnetic activity measured from the photometric variability. Results: The asteroseismic measurements without the application of priors are unable to place meaningful limits on the radial shear. Using a prior on the envelope rotation enables us to constrain the interior rotation rate and thus the radial shear. In the five cases that we studied, the interior rotation rate does not differ from the envelope by more than approximately ± 30%. Uncertainties in the rotational splittings are too large to unambiguously determine the sign of the radial shear.

  16. Rotational glenohumeral adaptations are associated with shoulder pathology in professional male handball players.

    PubMed

    Lubiatowski, Przemyslaw; Kaczmarek, Piotr; Cisowski, Pawel; Breborowicz, Ewa; Grygorowicz, Monika; Dzianach, Marcin; Krupecki, Tomasz; Laver, Lior; Romanowski, Leszek

    2018-01-01

    Glenohumeral range of motion adaptations may affect throwing athletes and contribute to shoulder injury. The purpose of this study was to evaluate shoulder rotation deficits among elite professional handball players and its correlation to the presence of shoulder pain and morphological changes. Eighty-seven elite professional handball players and 41 healthy non-athlete volunteers participated in the study. Evaluations included measurement of range of internal and external rotation, total arch of motion, identification of shoulder pain and ultrasound scan for diagnosis of rotator cuff tears and internal impingement. Glenohumeral rotational deficits (>20-25°) were found among 11 players group (13%). The throwing shoulders in the players group showed a decrease in internal rotation and an increase in external rotation with significantly larger ranges among players compared to the non-athlete group. Internal rotation deficit >20° was associated with higher incidence of shoulder pain among players. Both internal rotation deficits (>25°) and total arch of motion deficit (>20°) co-existed with higher incidence of internal impingement. Shoulder pain was common (36/97-41%) and was associated with decreased external rotation and total arch of motion. Internal impingement (found in 13/87-15%) correlated with decreased rotation ranges and a greater deficit in total arch of motion, whereas higher gain in external rotation correlated with a partial rotator cuff tear (found in 12/87-14%). Shoulder pathologies and problems commonly affected the group of handball players. Greater glenohumeral rotational deficits in throwing shoulders of handball players correlate with shoulder pain and internal impingement, while increased external rotation with partial rotator cuff tears. Such deficits affect 13% of the athlete population. Major clinical relevance of the study is to monitor handball players' shoulders both clinically and by proper imaging. Evaluation of range of rotation seems to identify shoulders at risk of the pathology. Cross-Sectional study with control group, Level II.

  17. Joint representation of translational and rotational components of optic flow in parietal cortex

    PubMed Central

    Sunkara, Adhira; DeAngelis, Gregory C.; Angelaki, Dora E.

    2016-01-01

    Terrestrial navigation naturally involves translations within the horizontal plane and eye rotations about a vertical (yaw) axis to track and fixate targets of interest. Neurons in the macaque ventral intraparietal (VIP) area are known to represent heading (the direction of self-translation) from optic flow in a manner that is tolerant to rotational visual cues generated during pursuit eye movements. Previous studies have also reported that eye rotations modulate the response gain of heading tuning curves in VIP neurons. We tested the hypothesis that VIP neurons simultaneously represent both heading and horizontal (yaw) eye rotation velocity by measuring heading tuning curves for a range of rotational velocities of either real or simulated eye movements. Three findings support the hypothesis of a joint representation. First, we show that rotation velocity selectivity based on gain modulations of visual heading tuning is similar to that measured during pure rotations. Second, gain modulations of heading tuning are similar for self-generated eye rotations and visually simulated rotations, indicating that the representation of rotation velocity in VIP is multimodal, driven by both visual and extraretinal signals. Third, we show that roughly one-half of VIP neurons jointly represent heading and rotation velocity in a multiplicatively separable manner. These results provide the first evidence, to our knowledge, for a joint representation of translation direction and rotation velocity in parietal cortex and show that rotation velocity can be represented based on visual cues, even in the absence of efference copy signals. PMID:27095846

  18. Differential Rotation in Sun-like Stars from Surface Variability and Asteroseismology

    NASA Astrophysics Data System (ADS)

    Nielsen, Martin Bo

    2017-03-01

    The Sun and other stars are known to oscillate. Through the study of small perturbations to the frequencies of these oscillations the rotation of the deep interior can be inferred. However, thus far the internal rotation of other Sun-like stars is unknown. The NASA Kepler mission has observed a multitude of Sun-like stars over a period of four years. This has provided high-quality photometric data that can be used to study the rotation of stars with two different techniques: asteroseismology and surface activity. Asteroseismology provides a means of measuring rotation in the stellar interior, while photometric variability from magnetically active regions are sensitive to rotation at the stellar surface. The combination of these two methods can be used to constrain the radial differential rotation in Sun-like stars. First, we developed an automated method for measuring the rotation of stars using surface variability. This method was initially applied to the entire Kepler catalog, out of which we detected signatures of rotation in 12,000 stars across the main sequence, providing robust estimates of the surface rotation rates and the associated errors. Second, we performed an asteroseismic analysis of six Sun-like stars, where we were able to measure the rotational splitting as a function of frequency in the p-mode envelope. This was done by dividing the oscillation spectrum into individual segments, and fitting a model independently to each segment. We found that the measured splittings were all consistent with a constant value, indicating little differential rotation. Third, we compared the asteroseismic rotation rates of five Sun-like stars to their surface rotation rates. We found that the values were in good agreement, again indicating little differential rotation between the regions where the two methods are most sensitive. Finally, we discuss how the surface rotation rates may be used as a prior on the seismic envelope rotation rate in a double-zone model, consisting of an independently-rotating radiative interior and convective envelope. Using such a prior we find that the rotation rates of the radiative interior and convective envelope likely do not differ by more than 50%. This further supports the idea that Sun-like stars likely show a rotation pattern similar to that of the Sun. Results from the analysis presented herein provide physical limits on the internal differential rotation of Sun-like stars, and show that this method may be easily applied to a wider variety of stars.

  19. Influence of the axial rotation angle on tool mark striations.

    PubMed

    Garcia, Derrel Louis; Pieterman, René; Baiker, Martin

    2017-10-01

    A tool's axial rotation influences the geometric properties of a tool mark. The larger the axial rotation angle, the larger the compression of structural details like striations. This complicates comparing tool marks at different axial rotations. Using chisels, tool marks were made from 0° to 75° axial rotation and compared using an automated approach Baiker et al. [10]. In addition, a 3D topographic surface of a chisel was obtained to generate virtual tool marks and to test whether the axial rotation angle of a mark could be predicted. After examination of the tool mark and chisel data-sets it was observed that marks lose information with increasing rotation due to the change in relative distance between geometrical details on the tool and the disappearance of smaller details. The similarity and repeatability were high for comparisons between marks with no difference in axial rotation, but decreasing with increased rotation angle from 0° to 75°. With an increasing difference in the rotation angles, the tool marks had to be corrected to account for the different compression factors between them. For compression up to 7.5%, this was obtained automatically by the tool mark alignment method. For larger compression, manually re-sizing the marks to the uncompressed widths at 0° rotation before the alignment was found suitable for successfully comparing even large differences in axial rotation. The similarity and repeatability were decreasing however, with increasing degree of re-sizing. The quality was assessed by determining the similarity at different detail levels within a tool mark. With an axial rotation up to 75°, tool marks were found to reliably represent structural details down to 100μm. The similarity of structural details below 100μm was dependent on the angle, with the highest similarity at small rotation angles and the lowest similarity at large rotation angles. Filtering to remove the details below 100μm lead to consistently higher similarity between tool marks at all angles and allowed for a comparison of marks up to 75° axial rotation. Finally, generated virtual tool mark profiles with an axial rotation were compared to experimental tool marks. The similarity between virtual and experimental tool marks remained high up to 60° rotation after which it decreased due to the loss in quality in both marks. Predicting the rotation angle is possible under certain conditions up to 45° rotation with an accuracy of 2.667±0.577° rotation. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Trirotron: triode rotating beam radio frequency amplifier

    DOEpatents

    Lebacqz, Jean V.

    1980-01-01

    High efficiency amplification of radio frequencies to very high power levels including: establishing a cylindrical cloud of electrons; establishing an electrical field surrounding and coaxial with the electron cloud to bias the electrons to remain in the cloud; establishing a rotating electrical field that surrounds and is coaxial with the steady field, the circular path of the rotating field being one wavelength long, whereby the peak of one phase of the rotating field is used to accelerate electrons in a beam through the bias field in synchronism with the peak of the rotating field so that there is a beam of electrons continuously extracted from the cloud and rotating with the peak; establishing a steady electrical field that surrounds and is coaxial with the rotating field for high-energy radial acceleration of the rotating beam of electrons; and resonating the rotating beam of electrons within a space surrounding the second field, the space being selected to have a phase velocity equal to that of the rotating field to thereby produce a high-power output at the frequency of the rotating field.

  1. Dynamic Electrorheological Effects of Rotating Particles:

    NASA Astrophysics Data System (ADS)

    Yu, K. W.; Gu, G. Q.; Huang, J. P.; Xiao, J. J.

    Particle rotation leads to a steady-state which is different from the equilibrium state in the absence of rotational motion. The change of the polarization of the particle due to the rotational motion is called the dynamic electrorheological effect (DER). There are three cases to be considered: rotating particles in a dc field, particle rotation due to a rotating field and spontaneous rotation of particle in dc field (Quincke rotation). In the DER of rotating particles, the particle rotational motion generally reduces the interparticle force between the particles. The effect becomes pronounced when the frequency is on the order of the relaxation rate of the surface charges. In the electrorotation of particles, the mutual interaction between approaching particles will change the electrorotation spectrum significantly. The electrorotation spectrum depends strongly on the medium conductivity as well as the conductivity contrast between the particle and the medium. In the collective behaviors of Quincke rotors, the mutual interactions between the individual rotors lead to the assembly of chain-like structures which make an angle with the applied field. This has an implication of a new class of material.

  2. Clinical Track Program Expansion Increases Rotation Capacity for Experiential Program.

    PubMed

    Tofade, Toyin S; Brueckl, Mark; Ross, Patricia A

    2017-10-01

    Objective. To evaluate the rotation capacity at the University of Maryland School of Pharmacy and see if the implementation of clinical track programs across the state correlates to an increase in rotation capacity for the school. Methods. The following information was collected: number of preceptors over the years in the school's experiential learning program, number of clinical track programs from 2012 to 2015, rotation type, availability submissions per rotation type per year, and availability submissions per hospital participant in the clinical track program per year. The rotation capacity and rotation types from 2012 to 2015 academic years were assessed and compared to see if there was any impact on the clinical track programs implemented. Results. There was no statistically significant difference in the frequency distribution of rotation types among all sites from 2012 through 2015 academic years. However, there was a statistically significant difference in the total number/capacity of rotations from 2012 to 2015 academic years. There were also statistically significant differences in the rotation capacity in all sites except for three sites. Conclusion. Adding clinical track programs can help increase the capacity of a school's clinical rotations.

  3. Hexagonal pattern instabilities in rotating Rayleigh-Bénard convection of a non-Boussinesq fluid: experimental results.

    PubMed

    Guarino, Alessio; Vidal, Valerie

    2004-06-01

    Motivated by the Küppers-Lortz instability of roll patterns in the presence of rotation, we have investigated the effects of rotation on a hexagonal pattern in Rayleigh-Bénard convection. While several theoretical models have been developed, experimental data cannot be found in the literature. In order to check the validity of the predictions and to study the effects of rotation on the behavior of the system, we present experimental results for a non-Boussinesq Rayleigh-Bénard convection with rotation about the vertical axis. Rotation introduces an additional control parameter, namely the dimensionless rotation rate Omega= 2 pi f d(2)/nu, where f is the rotation rate (in Hz), d is the thickness of the cell, and nu is the kinematic viscosity. We observe that the cell rotation induces a slow rotation of the pattern in the opposite direction (approximately Omega x 10(-4) ) in the rotating frame. Moreover, it tends to destroy the convective pattern. No oscillation of the hexagonal pattern over the range of its existence (Omega< or =6) has been observed.

  4. Beyond the Unified Model

    NASA Astrophysics Data System (ADS)

    Frauendorf, S.

    2018-04-01

    The key elements of the Unified Model are reviewed. The microscopic derivation of the Bohr Hamiltonian by means of adiabatic time-dependent mean field theory is presented. By checking against experimental data the limitations of the Unified Model are delineated. The description of the strong coupling between the rotational and intrinsic degrees of freedom in framework of the rotating mean field is presented from a conceptual point of view. The classification of rotational bands as configurations of rotating quasiparticles is introduced. The occurrence of uniform rotation about an axis that differs from the principle axes of the nuclear density distribution is discussed. The physics behind this tilted-axis rotation, unknown in molecular physics, is explained on a basic level. The new symmetries of the rotating mean field that arise from the various orientations of the angular momentum vector with respect to the triaxial nuclear density distribution and their manifestation by the level sequence of rotational bands are discussed. Resulting phenomena, as transverse wobbling, rotational chirality, magnetic rotation and band termination are discussed. Using the concept of spontaneous symmetry breaking the microscopic underpinning of the rotational degrees is refined.

  5. Quasi-radial modes of rotating stars in general relativity

    NASA Astrophysics Data System (ADS)

    Yoshida, Shin'ichirou; Eriguchi, Yoshiharu

    2001-04-01

    By using the Cowling approximation, quasi-radial modes of rotating general relativistic stars are computed along equilibrium sequences from non-rotating to maximally rotating models. The eigenfrequencies of these modes are decreasing functions of the rotational frequency. The eigenfrequency curve of each mode as a function of the rotational frequency has discontinuities, which arise from the avoided crossing with other curves of axisymmetric modes.

  6. Premolar and molar rotation in wild Japanese serow populations on Honshu Island, Japan.

    PubMed

    Natsume, Asuka; Koyasu, Kazuhiro; Oda, Sen-ichi; Nakagaki, Haruo; Hanamura, Hajime

    2006-11-01

    The skulls of 1195 Japanese serow (Capricornis crispus) from six geographically distinct populations were examined for tooth rotation. Our objectives were to determine tooth rotation patterns in Japanese serows, investigate geographical variation in tooth rotation and examine whether space limitations in the jaw accounted for variations. We then sought to explain the origin of tooth rotation in the Japanese serow. Rotated teeth were found in 131 specimens (62 males, 57 females and 12 unknown gender), with no statistically significant difference between males and females (chi(2)=0.03, P=0.86, d.f.=1). Among the six populations, the frequency of tooth rotation varied from 3.7-32.1% (average 11.0%). Most tooth rotation occurred in the upper third and fourth premolars. The lingual cusp of anomalous teeth was rotated 30 degrees -90 degrees mesially or distally from the buccolingual tooth axis, and the rotation direction differed among populations. However, we found no difference in skull or tooth morphology between normal individuals and those with tooth rotation. Therefore, hereditary factors may be involved in Japanese serow tooth rotation. We concluded that genetic differentiation occurred in the past among local Japanese serow populations isolated in mountainous habitats. Gene frequencies were likely subject to random drift, especially during possible population bottlenecks, when genetic factors could most strongly affect the direction of rotation.

  7. Rotational characterization of methyl methacrylate: Internal dynamics and structure determination

    NASA Astrophysics Data System (ADS)

    Herbers, Sven; Wachsmuth, Dennis; Obenchain, Daniel A.; Grabow, Jens-Uwe

    2018-01-01

    Rotational constants, Watson's S centrifugal distortion coefficients, and internal rotation parameters of the two most stable conformers of methyl methacrylate were retrieved from the microwave spectrum. Splittings of rotational energy levels were caused by two non equivalent methyl tops. Constraining the centrifugal distortion coefficients and internal rotation parameters to the values of the main isotopologues, the rotational constants of all single substituted 13C and 18O isotopologues were determined. From these rotational constants the substitution structures and semi-empirical zero point structures of both conformers were precisely determined.

  8. Controllable High-Speed Rotation of Nanowires

    NASA Astrophysics Data System (ADS)

    Fan, D. L.; Zhu, F. Q.; Cammarata, R. C.; Chien, C. L.

    2005-06-01

    We report a versatile method for executing controllable high-speed rotation of nanowires by ac voltages applied to multiple electrodes. The rotation of the nanowires can be instantly switched on or off with precisely controlled rotation speed (to at least 1800 rpm), definite chirality, and total angle of rotation. We have determined the torque due to the fluidic drag force on nanowire of different lengths. We also demonstrate a micromotor using a rotating nanowire driving a dust particle into circular motion. This method has been used to rotate magnetic and nonmagnetic nanowires as well as carbon nanotubes.

  9. Rotational coherent anti-stokes Raman spectroscopy measurements in a rotating cavity with axial throughflow of cooling air: oxygen concentration measurements.

    PubMed

    Black, J D; Long, C A

    1992-07-20

    In a rotating cavity rig, which models cooling air flow in the spaces between disks of a gas turbine compressor, the buildup of oxygen concentration after the cooling gas was changed from nitrogen to air was monitored using rotational coherent anti-Stokes Raman spectroscopy (CARS). From this information an estimate of the fraction of the throughflow entering the rotating cavity was obtained. This demonstrates that rotational CARS can be applied as a nonintrusive concentration-measurement technique in a rotating engineering test rig.

  10. Recovering Wood and McCarthy's ERP-prototypes by means of ERP-specific procrustes-rotation.

    PubMed

    Beauducel, André

    2018-02-01

    The misallocation of treatment-variance on the wrong component has been discussed in the context of temporal principal component analysis of event-related potentials. There is, until now, no rotation-method that can perfectly recover Wood and McCarthy's prototypes without making use of additional information on treatment-effects. In order to close this gap, two new methods: for component rotation were proposed. After Varimax-prerotation, the first method identifies very small slopes of successive loadings. The corresponding loadings are set to zero in a target-matrix for event-related orthogonal partial Procrustes- (EPP-) rotation. The second method generates Gaussian normal distributions around the peaks of the Varimax-loadings and performs orthogonal Procrustes-rotation towards these Gaussian distributions. Oblique versions of this Gaussian event-related Procrustes- (GEP) rotation and of EPP-rotation are based on Promax-rotation. A simulation study revealed that the new orthogonal rotations recover Wood and McCarthy's prototypes and eliminate misallocation of treatment-variance. In an additional simulation study with a more pronounced overlap of the prototypes GEP Promax-rotation reduced the variance misallocation slightly more than EPP Promax-rotation. Comparison with Existing Method(s): Varimax- and conventional Promax-rotations resulted in substantial misallocations of variance in simulation studies when components had temporal overlap. A substantially reduced misallocation of variance occurred with the EPP-, EPP Promax-, GEP-, and GEP Promax-rotations. Misallocation of variance can be minimized by means of the new rotation methods: Making use of information on the temporal order of the loadings may allow for improvements of the rotation of temporal PCA components. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. How good a clock is rotation? The stellar rotation-mass-age relationship for old field stars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Epstein, Courtney R.; Pinsonneault, Marc H., E-mail: epstein@astronomy.ohio-state.edu, E-mail: pinsono@astronomy.ohio-state.edu

    2014-01-10

    The rotation-mass-age relationship offers a promising avenue for measuring the ages of field stars, assuming the attendant uncertainties to this technique can be well characterized. We model stellar angular momentum evolution starting with a rotation distribution from open cluster M37. Our predicted rotation-mass-age relationship shows significant zero-point offsets compared to an alternative angular momentum loss law and published gyrochronology relations. Systematic errors at the 30% level are permitted by current data, highlighting the need for empirical guidance. We identify two fundamental sources of uncertainty that limit the precision of rotation-based ages and quantify their impact. Stars are born with amore » range of rotation rates, which leads to an age range at fixed rotation period. We find that the inherent ambiguity from the initial conditions is important for all young stars, and remains large for old stars below 0.6 M {sub ☉}. Latitudinal surface differential rotation also introduces a minimum uncertainty into rotation period measurements and, by extension, rotation-based ages. Both models and the data from binary star systems 61 Cyg and α Cen demonstrate that latitudinal differential rotation is the limiting factor for rotation-based age precision among old field stars, inducing uncertainties at the ∼2 Gyr level. We also examine the relationship between variability amplitude, rotation period, and age. Existing ground-based surveys can detect field populations with ages as old as 1-2 Gyr, while space missions can detect stars as old as the Galactic disk. In comparison with other techniques for measuring the ages of lower main sequence stars, including geometric parallax and asteroseismology, rotation-based ages have the potential to be the most precise chronometer for 0.6-1.0 M {sub ☉} stars.« less

  12. Association between rotation-related impairments and activity type in people with and without low back pain

    PubMed Central

    Weyrauch, Stephanie A.; Bohall, Sara C.; Sorensen, Christopher J.; Van Dillen, Linda R.

    2015-01-01

    Objective To determine if people with low back pain (LBP) who regularly participated in a rotation-related activity displayed more rotation-related impairments than people without LBP who did and did not participate in the activity. Design Secondary analysis of data from a case-control study. Setting Musculoskeletal analysis laboratory at an academic medical center. Participants A convenience sample of 55 participants with LBP who participated in a rotation-related sport, 26 back healthy controls who participated in a rotation-related sport (BHC+RRS) and 42 back healthy controls who did not participate in a rotation-related sport (BHC-RRS). Participants were matched based on age, gender, and activity level. Interventions Not applicable. Main Outcome Measures The total number of rotation-related impairments and asymmetric rotation-related impairments identified during a standardized clinical examination. Results Compared to the BHC-RRS group, both the LBP and BHC+RRS groups displayed significantly more (1) rotation-related impairments (LBP: p<.001; BHC+RRS: p=.015) (2) asymmetric rotation-related impairments (LBP: p=.006; BHC+RRS: p=.020) and (3) rotation-related impairments with trunk movement tests (LBP: p=.002; BHC+RRS: p<.001). The LBP group had significantly more rotation-related impairments with extremity movement tests than both of the back healthy groups (BHC+RRS: p=.011; BHC-RRS: p<.001). Conclusions LBP and BHC+RRS groups demonstrated a similar number of total rotation-related impairments and asymmetric rotation-related impairments, and these numbers were greater than those of the BHC-RRS group. Compared to people without LBP, people with LBP displayed more rotation-related impairments when moving an extremity. These findings suggest that impairments associated with extremity movements may be associated with having a LBP condition. PMID:25933914

  13. Calculation of impurity poloidal rotation from measured poloidal asymmetries in the toroidal rotation of a tokamak plasma.

    PubMed

    Chrystal, C; Burrell, K H; Grierson, B A; Groebner, R J; Kaplan, D H

    2012-10-01

    To improve poloidal rotation measurement capabilities on the DIII-D tokamak, new chords for the charge exchange recombination spectroscopy (CER) diagnostic have been installed. CER is a common method for measuring impurity rotation in tokamak plasmas. These new chords make measurements on the high-field side of the plasma. They are designed so that they can measure toroidal rotation without the need for the calculation of atomic physics corrections. Asymmetry between toroidal rotation on the high- and low-field sides of the plasma is used to calculate poloidal rotation. Results for the main impurity in the plasma are shown and compared with a neoclassical calculation of poloidal rotation.

  14. Centrifugally activated bearing for high-speed rotating machinery

    DOEpatents

    Post, Richard F.

    1994-01-01

    A centrifugally activated bearing is disclosed. The bearing includes an annular member that extends laterally and radially from a central axis. A rotating member that rotates about the central axis relative to the annular member is also included. The rotating member has an interior chamber that surrounds the central axis and in which the annular member is suspended. Furthermore, the interior chamber has a concave shape for retaining a lubricant therein while the rotating member is at rest and for retaining a lubricant therein while the rotating member is rotating. The concave shape is such that while the rotating member is rotating a centrifugal force causes a lubricant to be forced away from the central axis to form a cylindrical surface having an axis collinear with the central axis. This centrifugally displaced lubricant provides restoring forces to counteract lateral displacement during operation.

  15. Advanced Prop-fan Engine Technology (APET) single- and counter-rotation gearbox/pitch change mechanism

    NASA Technical Reports Server (NTRS)

    Reynolds, C. N.

    1985-01-01

    The preliminary design of advanced technology (1992) turboprop engines for single-rotation prop-fans and conceptual designs of pitch change mechanisms for single- and counter-rotation prop-fan application are discussed. The single-rotation gearbox is a split path, in-line configuration. The counter-rotation gearbox is an in-line, differential planetary design. The pitch change mechanisms for both the single- and counter-rotation arrangements are rotary/hydraulic. The advanced technology single-rotation gearbox yields a 2.4 percent improvement in aircraft fuel burn and a one percent improvement in operating cost relative to a current technology gearbox. The 1992 counter-rotation gearbox is 15 percent lighter, 15 percent more reliable, 5 percent lower in cost, and 45 percent lower in maintenance cost than the 1992 single-rotation gearbox. The pitch controls are modular, accessible, and external.

  16. Job rotation in nursing: a study of job rotation among nursing personnel from the literature and via a questionnaire.

    PubMed

    Järvi, Maija; Uusitalo, Tarja

    2004-09-01

    To obtain information on job rotation among nursing personnel from the literature and via a questionnaire. A nursing career no longer means a series of steps leading up a hierarchy. It has become more like a process of individual growth, involving improvement of employee expertise and skills. Job rotation in connection with career development in a Finnish hospital is considered essential, and participating in job rotation is one requirement for newly vacant nursing posts. Describing job rotation by means of reference to literature, and studying a survey on attitudes of ophthalmic nurses (n = 84) to job rotation. There has been little theoretical or empirical research on job rotation. In this study, one in three had participated in job rotation that was most often considered a positive experience. Self-development was rated substantially useful, but fewer were interested in participating in various kinds of developmental activities. Employee's motivation is the foundation of successful development activity, e.g. job rotation.

  17. Communication: Creation of molecular vibrational motions via the rotation-vibration coupling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shu, Chuan-Cun; School of Engineering and Information Technology, University of New South Wales at the Australian Defence Force Academy, Canberra, ACT 2600; Henriksen, Niels E., E-mail: neh@kemi.dtu.dk

    2015-06-14

    Building on recent advances in the rotational excitation of molecules, we show how the effect of rotation-vibration coupling can be switched on in a controlled manner and how this coupling unfolds in real time after a pure rotational excitation. We present the first examination of the vibrational motions which can be induced via the rotation-vibration coupling after a pulsed rotational excitation. A time-dependent quantum wave packet calculation for the HF molecule shows how a slow (compared to the vibrational period) rotational excitation leads to a smooth increase in the average bond length whereas a fast rotational excitation leads to amore » non-stationary vibrational motion. As a result, under field-free postpulse conditions, either a stretched stationary bond or a vibrating bond can be created due to the coupling between the rotational and vibrational degrees of freedom. The latter corresponds to a laser-induced breakdown of the adiabatic approximation for rotation-vibration coupling.« less

  18. Isometric hip-rotator torque production at varying degrees of hip flexion.

    PubMed

    Johnson, Sam; Hoffman, Mark

    2010-02-01

    Hip torque production is associated with certain knee injuries. The hip rotators change function depending on hip angle. To compare hip-rotator torque production between 3 angles of hip flexion, limbs, and sexes. Descriptive. University sports medicine research laboratory. 15 men and 15 women, 19-39 y. Three 6-s maximal isometric contractions of the hip external and internal rotators at 10 degrees, 40 degrees, and 90 degrees of hip flexion on both legs. Average torque normalized to body mass. Internal-rotation torque was greatest at 90 degrees of hip flexion, followed by 40 degrees of hip flexion and finally 10 degrees of hip flexion. External-rotation torque was not different based on hip flexion. The nondominant leg's external rotators were stronger than the dominant leg's, but the reverse was true for internal rotators. Finally, the men had more overall rotator torque. Hip-rotation torque production varies between flexion angle, leg, and sex. Clinicians treating lower extremity problems need to be aware of these differences.

  19. Rotational properties of planetary satellites

    NASA Technical Reports Server (NTRS)

    Peale, S. J.

    1991-01-01

    Properties of satellite rotation that are observable in principle, include the rotation period, the orientation of the spin axis relative to the orbit plane, precession of the spin axis due to gravitational torques, nonprincipal axis rotation or wobble, and deviations from uniform principle axis rotation or libration. Considerable order is observed in current satellite rotation states, and it is of interest to ascertain how this order came about and why some satellites do not conform to the dominant norm. There is a strong coupling between the spin and orbital motions that is primarily responsible for maintaining the ordered rotation states in most cases, but this coupling is equally responsible for destroying any chance of orderly rotation for Saturn's satellite Hyperion. Understanding the processes which constrain current rotation states as well as those of an evolutionary nature which could have brought the individual satellites to their observed rotation and orbit states allows us to sometimes infer interior properties of some satellite or even of its primary planet, although, attempts to deduce primordial rotation states are usually frustrated. The observed rotational properties of the planetary satellites are summarized, and the understanding of the processes maintaining and those leading to the observed states are outlined. Some of the inferences that can be drawn about intrinsic properties of the bodies themselves are indicated.

  20. A study of safety and tolerability of rotatory vestibular input for preschool children

    PubMed Central

    Su, Wen-Ching; Lin, Chin-Kai; Chang, Shih-Chung

    2015-01-01

    The objectives of this study were to determine a safe rotatory vestibular stimulation input for preschool children and to study the effects of grade level and sex of preschool children during active, passive, clockwise, and counterclockwise rotation vestibular input. This study adopted purposive sampling with 120 children from three kindergarten levels (K1, K2, and K3) in Taiwan. The subjects ranged in age from 46 to 79 months of age (mean: 62.1 months; standard deviation =9.60). This study included testing with four types of vestibular rotations. The number, duration, and speed of rotations were recorded. The study found that the mean number of active rotations was 10.28; the mean duration of rotation was 24.17 seconds; and the mean speed was 2.29 seconds per rotation. The mean number of passive rotations was 23.04. The differences in number of rotations in clockwise, counterclockwise, active, and passive rotations were not statistically significant. Sex and grade level were not important related factors in the speed and time of active rotation. Different sexes, rotation methods (active, passive), and grades made significant differences in the number of rotations. The safety and tolerability of rotatory vestibular stimulation input data obtained in this study can provide useful reference data for therapists using sensory integration therapy. PMID:25657579

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Triana, S. A.; Moravveji, E.; Pápics, P. I.

    The internal angular momentum distribution of a star is the key to determining its evolution. Fortunately, stellar internal rotation can be probed through studies of rotationally split nonradial oscillation modes. In particular, the detection of nonradial gravity modes (g modes) in massive young stars has recently become feasible thanks to the Kepler space mission. Our goal is to derive the internal rotation profile of the Kepler B8V star KIC 10526294 through asteroseismology. We interpret the observed rotational splittings of its dipole g modes using four different approaches based on the best seismic models of the star and their rotational kernels.more » We show that these kernels can resolve differential rotation within the radiative envelope if a smooth rotational profile is assumed and if the observational errors are small. Based on Kepler data, we find that the rotation rate near the core-envelope boundary is well constrained to 163 ± 89 nHz. The seismic data are consistent with rigid rotation but a profile with counter-rotation within the envelope has a statistical advantage over constant rotation. Our study should be repeated for other massive stars with a variety of stellar parameters in order to determine the physical conditions that control the internal rotation profile of young massive stars, with the aim of improving the input physics of their models.« less

  2. Left ventricular rotation and torsion in patients with perimembranous ventricular septal defect.

    PubMed

    Zhuang, Yan; Yong, Yong-hong; Yao, Jing; Ji, Ling; Xu, Di

    2014-03-01

    Assessment of left ventricular (LV) rotation has become an important approach for quantifying LV function. In this study, we sought to analyze LV rotation and twist using speckle tracking imaging (STI) in adult patients with isolated ventricular septal defects. Using STI, the peak rotation and time to peak rotation of 6 segments in basal and apical short-axis were measured, respectively, in 32 patients with ventricular septal defect and 30 healthy subjects as controls. The global rotation of the 6 segments in basal and apical and LV twist versus time profile were drawn, the peak rotation and twist of LV were calculated. All the time to peak rotation/twist were expressed as a percentage of end-systole (end-systole = 100%). Left ventricular ejection fraction was measured by biplane Simpson method. In patients group, the peak rotation of posterior, inferior, and postsept wall in basal was higher(P ≤ 0.05) and LV twist was also higher (P ≤ 0.05) than healthy controls. There were no significant differences between 2 groups in the peak rotation of the other 9 segments and left ventricular ejection fraction. Different from the control group, the time to peak rotation of the 6 segments in basal were delayed and the global rotation of the base was delayed (P ≤ 0.05) in ventricular septal defect group. Left ventricular volume overload due to ventricular septal defect has significant effect on LV rotation and twist, and LV rotation and twist may be a new index predicting LV systolic function. © 2013, Wiley Periodicals, Inc.

  3. Femoral component rotation in patellofemoral joint replacement.

    PubMed

    van Jonbergen, Hans-Peter W; Westerbeek, Robin E

    2018-06-01

    Clinical outcomes in patellofemoral joint replacement may be related to femoral component rotation. Assessment of rotational alignment is however difficult as patients with isolated patellofemoral osteoarthritis often have trochlear dysplasia. The use of the medial malleolus as a landmark to guide rotation has been suggested. The purpose of our study was to evaluate this technique with regard to femoral component rotation, and to correlate rotation with clinical outcomes at one-year follow-up. Forty-one knees in 39 patients had patellofemoral joint replacement using the Zimmer Gender-Solutions patellofemoral prosthesis. Intraoperatively, we determined femoral component rotational alignment using an extramedullary rod aimed at the inferior tip of the medial malleolus. Postoperatively, we measured the angle between the femoral component and the anatomical transepicondylar axis using CT. The amount of rotation was correlated with clinical outcomes at one-year follow-up. Forty knees in 38 patients were available for one-year follow-up. Mean femoral component rotation relative to the anatomical transepicondylar axis was 1.4° external rotation (range, -3.8 to 5.7°). We found no statistically significant correlation between femoral component rotation and change from baseline KOOS subscales at one-year follow-up. Our findings show that when using the medial malleolus as a landmark to guide rotation, the femoral component of the patellofemoral prosthesis was oriented in external rotation relative to the anatomical transepicondylar axis in 80% of knees. Our study did not show a relation between the amount of external rotation and clinical outcomes. Level III. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Does proprioceptive acuity during active knee rotation in the transverse plane vary at different ranges?

    PubMed

    Muaidi, Qassim I

    2016-11-21

    Knee proprioception in the sagittal plane has been widely investigated in prospective studies, however limited information is known about proprioceptive acuity during active knee rotation and the way most commonly injured. To investigate whether proprioceptive acuity during active internal and external knee rotation varies at different ranges in the transverse plane. Healthy volunteers (N: 26) without previous injury or surgery of the knee joint participated in the study.Knee rotation proprioceptive acuity was measured using a custom-designed device. The measure of proprioceptive acuity used in this study was the just-noticeable-difference (JND). Participants actively rotated the knee at different intervals(initial, mid, and terminal internal or external rotation range) to one of four movement blocks and the magnitude of the permitted motion was judged. The means of the JND for proprioceptive acuity at initial internal rotation (0.80° ± 0.06) were significantly (p< 0.002) lower than for mid (1.62° ± 0.18), and terminal (2.08° ± 0.35) internal rotation. The means of the JND for proprioceptive acuity at initial external rotation (1.16° ± 0.10) were significantly (p< 0.04) lower than for mid (1.95° ± 0.30), and terminal (1.97° ± 0.24) internal rotation. Participants perceived smaller differences between active internal and external rotation movements at initial rotation range than at the mid and terminal rotation range of movement. This suggests better proprioceptive acuity at the initial rotation range of movement in the transverse plane.

  5. Managing carbon sinks in rubber (Hevea brasilensis) plantation by changing rotation length in SW China.

    PubMed

    Nizami, Syed Moazzam; Yiping, Zhang; Liqing, Sha; Zhao, Wei; Zhang, Xiang

    2014-01-01

    Extension of the rotation length in forest management has been highlighted in Article 3.4 of the Kyoto Protocol to help the countries in their commitments for reduction in greenhouse gas emissions. CO2FIX Model Ver.3.2 was used to examine the dynamics of carbon stocks (C stocks) in a rubber plantation in South Western China with the changing rotation lengths. To estimate the efficiency of increasing the rotation length as an Article 3.4 activity, study predicted that the rubber production and C stocks of the ecosystem increased with the increasing rotation (25, 30, 35, 40 and 45 years). While comparing the pace of growth both in economical (rubber production) and ecological (C stocks) terms in each rotation, 40 years rotation length showed maximum production and C stocks. After elongation of 40 year rotation to four consecutive cycles, it was concluded that the total C stocks of the ecosystem were 186.65 Mg ha(-1). The longer rotation lengths showed comparatively increased C stocks in below ground C stock after consecutive four rotations. The pace of C input (Mg C ha(-1) yr(-1)) and rubber production indicated that 40 years rotation is best suited for rubber plantation. The study has developed carbon mitigation based on four rotation scenarios. The possible stimulated increase in C stocks of the entire ecosystem after consecutive long rotations indicated that the emphasis must be paid on deciding the rotation of rubber plantation in SW China for reporting under article 3.4 of the Kyoto Protocol.

  6. Managing Carbon Sinks in Rubber (Hevea brasilensis) Plantation by Changing Rotation length in SW China

    PubMed Central

    Nizami, Syed Moazzam; Yiping, Zhang; Liqing, Sha; Zhao, Wei; Zhang, Xiang

    2014-01-01

    Extension of the rotation length in forest management has been highlighted in Article 3.4 of the Kyoto Protocol to help the countries in their commitments for reduction in greenhouse gas emissions. CO2FIX Model Ver.3.2 was used to examine the dynamics of carbon stocks (C stocks) in a rubber plantation in South Western China with the changing rotation lengths. To estimate the efficiency of increasing the rotation length as an Article 3.4 activity, study predicted that the rubber production and C stocks of the ecosystem increased with the increasing rotation (25, 30, 35, 40 and 45 years). While comparing the pace of growth both in economical (rubber production) and ecological (C stocks) terms in each rotation, 40 years rotation length showed maximum production and C stocks. After elongation of 40 year rotation to four consecutive cycles, it was concluded that the total C stocks of the ecosystem were 186.65 Mg ha-1. The longer rotation lengths showed comparatively increased C stocks in below ground C stock after consecutive four rotations. The pace of C input (Mg C ha-1yr-1) and rubber production indicated that 40years rotation is best suited for rubber plantation. The study has developed carbon mitigation based on four rotation scenarios. The possible stimulated increase in C stocks of the entire ecosystem after consecutive long rotations indicated that the emphasis must be paid on deciding the rotation of rubber plantation in SW China for reporting under article 3.4 of the Kyoto Protocol. PMID:25536041

  7. Effects of the Tongue-in-Groove Maneuver on Nasal Tip Rotation.

    PubMed

    Antunes, Marcelo B; Quatela, Vito C

    2018-03-27

    Changes in nasal tip rotation is a very common maneuver performed during rhinoplasty. Among the many techniques used to achieve this goal is the tongue-in-groove (TIG). This study addresses the long-term effect of the TIG on the nasal tip rotation 1 year after rhinoplasty. The authors prospectively identified patients who were submitted to a rhinoplasty with a TIG maneuver over a period of 1 year. The angle of rotation was measured along the nostril axis angle. The data was analyzed using the t-test and a linear regression model. Seventeen patients were included. The average preoperative tip rotation was 93.95° (SD, 3.12°). Immediate postoperative tip rotation averaged 114.47° (SD, 3.79°). At the 1-year follow-up appointment, the tip rotation averaged 106.55° (SD, 3.54°). There was a significant loss of rotation at the 1-year postoperative visit (p<0.0001), with an average loss of 7.9° (SD, 3.25°), which amounted to 6.8%. The preoperative rotation didn't affect the amount of loss of rotation (p=0.04). It can be estimated that, for every degree of rotation that is changed at surgery it can be expected to lose 0.35 degrees over the first year. TIG is a more dependable technique than the ones that rely on healing and contraction to obtain rotation. Our data demonstrated a significant loss of rotation during the first year. This suggests that the surgeon needs to slightly overcorrect the tip rotation to account for this loss.

  8. Does a critical rotator cuff tear stage exist?: a biomechanical study of rotator cuff tear progression in human cadaver shoulders.

    PubMed

    Oh, Joo Han; Jun, Bong Jae; McGarry, Michelle H; Lee, Thay Q

    2011-11-16

    It is unknown at which stage of rotator cuff tear the biomechanical environment is altered. The purpose of this study was to determine if a critical rotator cuff tear stage exists that alters glenohumeral joint biomechanics throughout the rotational range of shoulder motion, and to evaluate the biomechanical effect of parascapular muscle-loading. Eight cadaver shoulders were used with a custom testing system. Four progressive rotator cuff tear stages were investigated on the basis of footprint anatomy. Three muscle-loading conditions were examined: rotator cuff only; rotator cuff with deltoid muscle; and rotator cuff, deltoid, pectoralis major, and latissimus dorsi muscles. Testing was performed in the scapular plane with 0°, 30°, and 60° of shoulder abduction. The maximum internal and external rotations were measured with 3.4 Nm of torque. The position of the humeral head apex with respect to the glenoid was calculated with use of a MicroScribe 3DLX digitizing system throughout the rotational range of motion. The abduction capability was determined as the abduction angle achieved with increasing deltoid load. Tear of the entire supraspinatus tendon significantly increased maximum external rotation and significantly decreased abduction capability with higher deltoid loads (p < 0.05). Tear of the entire supraspinatus tendon and half of the infraspinatus tendon significantly shifted the humeral head apex posteriorly at the midrange of rotation and superiorly at maximum internal rotation (p < 0.05). Loading the pectoralis major and latissimus dorsi muscles decreased the amount of humeral head elevation due to deltoid loading. Tear of the entire supraspinatus tendon was the critical stage for increasing rotational range of shoulder motion and for decreased abduction capability. Further tear progression to the infraspinatus muscle was the critical stage for significant changes in humeral head kinematics. The pectoralis major and latissimus dorsi muscles played an important role in stabilizing the humeral head as the rotator cuff tear progressed.

  9. Trunk rotational strength asymmetry in adolescents with idiopathic scoliosis: an observational study

    PubMed Central

    McIntire, Kevin L; Asher, Marc A; Burton, Douglas C; Liu, Wen

    2007-01-01

    Background Recent reports have suggested a rotational strength weakness in rotations to the concave side in patients with idiopathic scoliosis. There have been no studies presenting normative values of female adolescent trunk rotational strength to which a comparison of female adolescents with idiopathic scoliosis could be made. The purpose of this study was to determine trunk rotational strength asymmetry in a group of female adolescents with AIS and a comparison group of healthy female adolescents without scoliosis. Methods Twenty-six healthy adolescent females served as the healthy group (HG) (average age 14 years) and fourteen otherwise healthy adolescent females with idiopathic scoliosis served as the idiopathic scoliosis group (ISG) (average age 13.5 years, average Cobb 28°). Participant's isometric trunk rotational strength was measured in five randomly ordered trunk positions: neutral, 18° and 36° of right and left pre-rotation. Rotational strength asymmetry was compared within each group and between the two groups using several different measures. Results The HG showed strength asymmetry in the 36° pre-rotated trunk positions when rotating towards the midline (p < 0.05). The ISG showed strength asymmetry when rotating towards the concavity of their primary curve from the neutral position (p < 0.05) and when rotating towards the concavity from the 18° (p < 0.05) and 36° (p < 0.05) concave pre-rotated positions. The ISG is significantly weaker than the HG when rotating away from the midline toward the concave (ISG)-left (HG) side from the concave/left pre-rotated 18° (p < 0.05) and 36° (p < 0.05) positions. Conclusion The AIS females were found to be significantly weaker when contracting toward their main curve concavity in the neutral and concave pre-rotated positions compared to contractions toward the convexity. These weaknesses were also demonstrated when compared to the group of healthy female adolescent controls. Possible mechanisms for the strength asymmetry in ISG are discussed. PMID:17620141

  10. Mental Rotation, Pictured Rotation, and Tandem Rotation in Depth

    DTIC Science & Technology

    1997-01-01

    field. Such an explanation by natural geometry conflates visual comparison with physical measurement. This application of geometry is called natural in...the theory of vision parasitic on geometry: it is unclear what could be meant by a ’mental operation of rotation’, except by reference to physical ...operation, a mental analogue of the physical operation of rotation in space. Since then the story of mental rotation has become far more complicated

  11. Thrust rollers

    NASA Technical Reports Server (NTRS)

    Vranish, John M. (Inventor)

    2007-01-01

    A thrust roller bearing system comprising an inner rotating member, an outer rotating member and multiple rollers coupling the inner rotating member with outer rotating member. The inner and outer rotating members include thrust lips to enable the rollers to act as thrust rollers. The rollers contact inner and outer rotating members at bearing contact points along a contact line. Consequently, the radial/tilt and thrust forces move synchronously and simultaneously to create a bearing action with no slipping.

  12. Impact of a counter-rotating planetary rotation system on thin-film thickness and uniformity

    DOE PAGES

    Oliver, J. B.

    2017-06-12

    Planetary rotation systems incorporating forward- and counter-rotating planets are used as a means of increasing coating-system capacity for large oblong substrates. Comparisons of planetary motion for the two types of rotating systems are presented based on point tracking for multiple revolutions, as well as comparisons of quantitative thickness and uniformity. Counter-rotation system geometry is shown to result in differences in thin-film thickness relative to standard planetary rotation for precision optical coatings. As a result, this systematic error in thin-film thickness will reduce deposition yields for sensitive coating designs.

  13. Impact of a counter-rotating planetary rotation system on thin-film thickness and uniformity.

    PubMed

    Oliver, J B

    2017-06-20

    Planetary rotation systems incorporating forward- and counter-rotating planets are used as a means of increasing coating-system capacity for large oblong substrates. Comparisons of planetary motion for the two types of rotating systems are presented based on point tracking for multiple revolutions as well as comparisons of quantitative thickness and uniformity. Counter-rotation system geometry is shown to result in differences in thin-film thickness relative to standard planetary rotation for precision optical coatings. This systematic error in thin-film thickness will reduce deposition yields for sensitive coating designs.

  14. Rotatable non-circular forebody flow controller

    NASA Technical Reports Server (NTRS)

    Moskovitz, Cary A. (Inventor)

    1991-01-01

    The invention is a rotatable, non-circular forebody flow controller. The apparatus comprises a small geometric device located at a nose of a forebody of an aircraft and a non-circular cross-sectional area that extends toward the apex of the aircraft. The device is symmetrical about a reference plane and preferably attaches to an axle which in turn attaches to a rotating motor. The motor rotates the device about an axis of rotation. Preferably, a control unit connected to an aircraft flight control computer signals to the rotating motor the proper rotational positioning of the geometric device.

  15. Detection of Brownian Torque in a Magnetically-Driven Rotating Microsystem

    PubMed Central

    Romodina, Maria N.; Lyubin, Evgeny V.; Fedyanin, Andrey A.

    2016-01-01

    Thermal fluctuations significantly affect the behavior of microscale systems rotating in shear flow, such as microvortexes, microbubbles, rotating micromotors, microactuators and other elements of lab-on-a-chip devices. The influence of Brownian torque on the motion of individual magnetic microparticles in a rotating magnetic field is experimentally determined using optical tweezers. Rotational Brownian motion induces the flattening of the breakdown transition between the synchronous and asynchronous modes of microparticle rotation. The experimental findings regarding microparticle rotation in the presence of Brownian torque are compared with the results of numerical Brownian dynamics simulations. PMID:26876334

  16. Impact of a counter-rotating planetary rotation system on thin-film thickness and uniformity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oliver, J. B.

    Planetary rotation systems incorporating forward- and counter-rotating planets are used as a means of increasing coating-system capacity for large oblong substrates. Comparisons of planetary motion for the two types of rotating systems are presented based on point tracking for multiple revolutions, as well as comparisons of quantitative thickness and uniformity. Counter-rotation system geometry is shown to result in differences in thin-film thickness relative to standard planetary rotation for precision optical coatings. As a result, this systematic error in thin-film thickness will reduce deposition yields for sensitive coating designs.

  17. Rotationally Vibrating Electric-Field Mill

    NASA Technical Reports Server (NTRS)

    Kirkham, Harold

    2008-01-01

    A proposed instrument for measuring a static electric field would be based partly on a conventional rotating-split-cylinder or rotating-split-sphere electric-field mill. However, the design of the proposed instrument would overcome the difficulty, encountered in conventional rotational field mills, of transferring measurement signals and power via either electrical or fiber-optic rotary couplings that must be aligned and installed in conjunction with rotary bearings. Instead of being made to rotate in one direction at a steady speed as in a conventional rotational field mill, a split-cylinder or split-sphere electrode assembly in the proposed instrument would be set into rotational vibration like that of a metronome. The rotational vibration, synchronized with appropriate rapid electronic switching of electrical connections between electric-current-measuring circuitry and the split-cylinder or split-sphere electrodes, would result in an electrical measurement effect equivalent to that of a conventional rotational field mill. A version of the proposed instrument is described.

  18. Centrifugally activated bearing for high-speed rotating machinery

    DOEpatents

    Post, R.F.

    1994-02-15

    A centrifugally activated bearing is disclosed. The bearing includes an annular member that extends laterally and radially from a central axis. A rotating member that rotates about the central axis relative to the annular member is also included. The rotating member has an interior chamber that surrounds the central axis and in which the annular member is suspended. Furthermore, the interior chamber has a concave shape for retaining a lubricant therein while the rotating member is at rest and for retaining a lubricant therein while the rotating member is rotating. The concave shape is such that while the rotating member is rotating a centrifugal force causes a lubricant to be forced away from the central axis to form a cylindrical surface having an axis collinear with the central axis. This centrifugally displaced lubricant provides restoring forces to counteract lateral displacement during operation. 4 figures.

  19. Resistive magnetohydrodynamics with toroidal rotation in toroidal plasmas

    NASA Astrophysics Data System (ADS)

    Cao, Jintao; Cai, Huishan

    2018-01-01

    Toroidal rotation has always existed in tokamak plasmas, and its Mach number can reach unity during neutral beam injection. Toroidal rotation can affect plasma equilibrium and magnetohydrodynamic instabilities significantly. Based on linearized equations including the toroidal rotation effect, the toroidal model derived by Glasser et al. [Phys. Fluids 18, 875 (1975)] is extended to include this effect, and a set of resistive equations including the toroidal rotation effect in the axi-symmetry toroidal geometry is derived. Based on these derived equations, the effect of toroidal rotation on tearing modes is considered, and the growth rate of tearing modes is obtained analytically. It is shown that the effect of toroidal rotation on tearing modes depends on both the direction of toroidal rotation flow and the sign of toroidal rotation flow shear. When they have the same sign, they play a role in stabilizing tearing modes, while when they have opposite signs, they have a destabilizing effect on tearing modes.

  20. Research on motor rotational speed measurement in regenerative braking system of electric vehicle

    NASA Astrophysics Data System (ADS)

    Pan, Chaofeng; Chen, Liao; Chen, Long; Jiang, Haobin; Li, Zhongxing; Wang, Shaohua

    2016-01-01

    Rotational speed signals acquisition and processing techniques are widely used in rotational machinery. In order to realized precise and real-time control of motor drive and regenerative braking process, rotational speed measurement techniques are needed in electric vehicles. Obtaining accurate motor rotational speed signal will contribute to the regenerative braking force control steadily and realized higher energy recovery rate. This paper aims to develop a method that provides instantaneous speed information in the form of motor rotation. It addresses principles of motor rotational speed measurement in the regenerative braking systems of electric vehicle firstly. The paper then presents ideal and actual Hall position sensor signals characteristics, the relation between the motor rotational speed and the Hall position sensor signals is revealed. Finally, Hall position sensor signals conditioning and processing circuit and program for motor rotational speed measurement have been carried out based on measurement error analysis.

  1. Controllable rotating behavior of individual dielectric microrod in a rotating electric field.

    PubMed

    Liu, Weiyu; Ren, Yukun; Tao, Ye; Li, Yanbo; Chen, Xiaoming

    2017-06-01

    We report herein controllable rotating behavior of an individual dielectric microrod driven by a background rotating electric field. By disposing or removing structured floating microelectrode, the rigid rod suspended in electrolyte solution accordingly exhibits cofield or antifield rotating motion. In the absence of the ideally polarizable metal surface, the dielectric rod rotates opposite to propagation of electric field, with the measured rotating rate much larger than predicted by Maxwell-Wager interfacial polarization theory incorporating surface conduction of fixed bond charge. Surprisingly, with floating electrode embedded, a novel kind of cofield rotation mode occurs in the presence of induced double-layer polarization, due to the action of hydrodynamic torque from rotating induced-charge electroosmosis. This method of achieving switchable spin modes of dielectric particles would direct implications in constructing flexible electrokinetic framework for analyzing 3D profile of on-chip biomicrofluidic samples. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Asteroid rotation. I - Tabulation and analysis of rates, pole positions and shapes. II - A theory for the collisional evolution of rotation rates

    NASA Technical Reports Server (NTRS)

    Harris, A. W.; Burns, J. A.

    1979-01-01

    Rotation properties and shape data for 182 asteroids are compiled and analyzed, and a collisional model for the evolution of the mean rotation rate of asteroids is proposed. Tabulations of asteroid rotation rates, taxonomic types, pole positions, sizes and shapes and plots of rotation frequency and light curve amplitude against size indicate that asteroid rotational frequency increases with decreasing size for all asteroids except those of the C or S classes. Light curve data also indicate that small asteroids are more irregular in shape than large asteroids. The dispersion in rotation rates observed is well represented by a three dimensional Maxwellian distribution, suggestive of collisional encounters between asteroids. In the proposed model, the rotation rate is found to tend toward an equilibrium value, at which spin-up due to infrequent, large collisions is balanced by a drag due to the larger number of small collisions. The lower mean rotation rate of C-type asteroids is attributed to a lower means density of that class, and the increase in rotation rate with decreasing size is interpreted as indicative of a substantial population of strong asteroids.

  3. Is computed tomography an accurate and reliable method for measuring total knee arthroplasty component rotation?

    PubMed

    Figueroa, José; Guarachi, Juan Pablo; Matas, José; Arnander, Magnus; Orrego, Mario

    2016-04-01

    Computed tomography (CT) is widely used to assess component rotation in patients with poor results after total knee arthroplasty (TKA). The purpose of this study was to simultaneously determine the accuracy and reliability of CT in measuring TKA component rotation. TKA components were implanted in dry-bone models and assigned to two groups. The first group (n = 7) had variable femoral component rotations, and the second group (n = 6) had variable tibial tray rotations. CT images were then used to assess component rotation. Accuracy of CT rotational assessment was determined by mean difference, in degrees, between implanted component rotation and CT-measured rotation. Intraclass correlation coefficient (ICC) was applied to determine intra-observer and inter-observer reliability. Femoral component accuracy showed a mean difference of 2.5° and the tibial tray a mean difference of 3.2°. There was good intra- and inter-observer reliability for both components, with a femoral ICC of 0.8 and 0.76, and tibial ICC of 0.68 and 0.65, respectively. CT rotational assessment accuracy can differ from true component rotation by approximately 3° for each component. It does, however, have good inter- and intra-observer reliability.

  4. The role of rotational hand movements and general motor ability in children’s mental rotation performance

    PubMed Central

    Jansen, Petra; Kellner, Jan

    2015-01-01

    Mental rotation of visual images of body parts and abstract shapes can be influenced by simultaneous motor activity. Children in particular have a strong coupling between motor and cognitive processes. We investigated the influence of a rotational hand movement performed by rotating a knob on mental rotation performance in primary school-age children (N = 83; age range: 7.0–8.3 and 9.0–10.11 years). In addition, we assessed the role of motor ability in this relationship. Boys in the 7- to 8-year-old group were faster when mentally and manually rotating in the same direction than in the opposite direction. For girls and older children this effect was not found. A positive relationship was found between motor ability and accuracy on the mental rotation task: stronger motor ability related to improved mental rotation performance. In both age groups, children with more advanced motor abilities were more likely to adopt motor processes to solve mental rotation tasks if the mental rotation task was primed by a motor task. Our evidence supports the idea that an overlap between motor and visual cognitive processes in children is influenced by motor ability. PMID:26236262

  5. The role of rotational hand movements and general motor ability in children's mental rotation performance.

    PubMed

    Jansen, Petra; Kellner, Jan

    2015-01-01

    Mental rotation of visual images of body parts and abstract shapes can be influenced by simultaneous motor activity. Children in particular have a strong coupling between motor and cognitive processes. We investigated the influence of a rotational hand movement performed by rotating a knob on mental rotation performance in primary school-age children (N = 83; age range: 7.0-8.3 and 9.0-10.11 years). In addition, we assessed the role of motor ability in this relationship. Boys in the 7- to 8-year-old group were faster when mentally and manually rotating in the same direction than in the opposite direction. For girls and older children this effect was not found. A positive relationship was found between motor ability and accuracy on the mental rotation task: stronger motor ability related to improved mental rotation performance. In both age groups, children with more advanced motor abilities were more likely to adopt motor processes to solve mental rotation tasks if the mental rotation task was primed by a motor task. Our evidence supports the idea that an overlap between motor and visual cognitive processes in children is influenced by motor ability.

  6. Visuomotor mental rotation of a saccade: The contingent negative variation scales to the angle of rotation.

    PubMed

    Heath, Matthew; Colino, Francisco L; Chan, Jillian; Krigolson, Olave E

    2018-02-01

    The visuomotor mental rotation (VMR) of a saccade requires a response to a region of space that is dissociated from a stimulus by a pre-specified angle, and work has shown a monotonic increase in reaction times as a function of increasing oblique angles of rotation. These results have been taken as evidence of a continuous process of rotation and have generated competing hypotheses. One hypothesis asserts that rotation is mediated via frontoparietal structures, whereas a second states that a continuous shift in the activity of direction-specific neurons in the superior colliculus (SC) supports rotation. Research to date, however, has not examined the neural mechanisms underlying VMR saccades and both hypotheses therefore remain untested. The present study measured the behavioural data and event-related brain potentials (ERP) of standard (i.e., 0° of rotation) and VMR saccades involving 35°, 70° and 105° of rotation. Behavioural results showed that participants adhered to task-based rotation demands and ERP findings showed that the amplitude of the contingent negative variation (CNV) linearly decreased with increasing angle of rotation. The cortical generators of the CNV are linked to frontoparietal structures supporting movement preparation. Although our ERP design does not allow us to exclude a possible role of the SC in the rotation of a VMR saccade, they do demonstrate that such actions are supported by a continuous and cortically based rotation process. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Rotational movements of mandibular two-implant overdentures.

    PubMed

    Kimoto, Suguru; Pan, Shaoxia; Drolet, Nicolas; Feine, Jocelyne S

    2009-08-01

    Clinicians have reported that their patients complain that their mandibular two-implant overdentures (IOD) rotate. Therefore, we studied the frequency and severity of rotation of IODs with two-ball attachments, how rotation may influence perceived satisfaction ratings of chewing ability, and the factors that are involved in the rotation of IODs. Seventy-nine participants were recruited and asked to rate their general satisfaction of their IODs, as well as their ability to chew foods, the existence of any mandibular denture rotation, and to what degree denture rotation bothered them. Data on participant sociodemographic, anatomical, and prosthesis characteristics were also collected. Student's t-test and logistic regression analyses were performed to analyze the differences between participants who did (R group) and did not report (NR group) denture rotation. Thirty-seven of 79 participants were aware of rotational movement in their IODs. These patients were significantly less satisfied with their chewing ability than those who felt no rotation (69.1 mm R group vs. 82.9 mm), and discomfort caused by the rotation bothered them moderately (39/100 mm). The multivariate logistic regression analysis revealed that the arrangement of the anterior teeth and the length of the denture are significantly associated with awareness of denture rotation. Thirty-eight percent in the R group and 31% in the NR group had non-scheduled visits. Rotational movement with a mandibular two-IOD has a negative effect on perceived chewing ability and is associated with anterior tooth arrangement and denture length.

  8. Shoulder internal rotation elbow flexion test for diagnosing cubital tunnel syndrome.

    PubMed

    Ochi, Kensuke; Horiuchi, Yukio; Tanabe, Aya; Waseda, Makoto; Kaneko, Yasuhito; Koyanagi, Takahiro

    2012-06-01

    Shoulder internal rotation enhances symptom provocation attributed to cubital tunnel syndrome. We present a modified elbow flexion test--the shoulder internal rotation elbow flexion test--for diagnosing cubital tunnel syndrome. Fifty-five ulnar nerves in cubital tunnel syndrome patients and 123 ulnar nerves in controls were examined with 5 seconds each of elbow flexion, shoulder internal rotation, and shoulder internal rotation elbow flexion tests before and after treatment (surgery in 18; conservative in others). For the shoulder internal rotation elbow flexion test position, 90° abduction, maximum internal rotation, and 10° flexion of the shoulder were combined with the elbow flexion test position. The test was considered positive if any symptom for cubital tunnel syndrome developed <5 seconds. Influence of the shoulder internal rotation elbow flexion test was evaluated by nerve conduction studies in 10 cubital tunnel syndrome nerves and 7 control nerves. The sensitivities/specificities of the 5-second elbow flexion, shoulder internal rotation, and shoulder internal rotation elbow flexion tests were 25%/100%, 58%/100%, and 87%/98%, respectively. Sensitivity differences between the shoulder internal rotation elbow flexion test and the other two tests were significant. Shoulder internal rotation elbow flexion test results and cubital tunnel syndrome symptoms were significantly correlated. Influence of the shoulder internal rotation elbow flexion test on the ulnar nerve was seen in 8 of 10 cubital tunnel syndrome nerves but not in controls. The 5-second shoulder internal rotation elbow flexion test is specific, easy and quick provocative test for diagnosing cubital tunnel syndrome. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  9. Optimized functional femoral rotation in navigated total knee arthroplasty considering ligament tension.

    PubMed

    Walde, T A; Bussert, J; Sehmisch, S; Balcarek, P; Stürmer, K M; Walde, H J; Frosch, K H

    2010-12-01

    Femoral malrotation in total knee arthroplasty is correlated to an increased number of revisions. Anatomic landmarks such as Whiteside line, posterior condyle axis and transepicondylar axis are used for determining femoral component rotation. The femoral rotation achieved with the anatomical landmarks is compared to the femoral rotation achieved by a navigated ligament tension-based tibia-first technique. Ninety-three consecutive patients with gonarthritis were prospectively enrolled. Intraoperatively the anatomical landmarks for femoral rotation and the achieved femoral rotation using a navigated tension-based tibia-first technique were determined and stored for further comparison. A pre- and postoperative functional diagram displaying the extension and flexion and varus or valgus positions was also part of the evaluation. Using anatomical landmarks the rotational errors ranged from 12.2° of internal rotation to 15.5° of external rotation from parallel to the tibial resection surface at 90° flexion. A statistical significant improved femoral rotation was achieved using the ligament tension-based method with a rotational error ranged from 3.0° of internal rotation to 2.4° of external rotation. The functional analyses demonstrated statistical significant lower varus/valgus deviations within the flexion range and an improved maximum varus deviation at 90° flexion using the ligament tension-based method. Compared to the anatomical landmarks a balanced, almost parallel flexion gap was achieved using a navigation technique taking the ligament tension of the knee joint into account. As a result the improved femoral rotation was demonstrated by the functional evaluation. Unilateral overloading of the polyethylene inlay and unilateral instability can thus be avoided. Copyright © 2009 Elsevier B.V. All rights reserved.

  10. Trunk-rotation flexibility in collegiate softball players with or without a history of shoulder or elbow injury.

    PubMed

    Aragon, Veronica J; Oyama, Sakiko; Oliaro, Scott M; Padua, Darin A; Myers, Joseph B

    2012-01-01

    Throwing is a whole-body motion that requires the transfer of momentum from the lower extremity to the upper extremity via the trunk. No research to date examines the association between a history of shoulder or elbow injury and trunk flexibility in overhead athletes. To determine if injury history and trunk-rotation flexibility are associated and to compare trunk-rotation flexibility measured using 3 clinical tests: half-kneeling rotation test with the bar in the back, half-kneeling rotation test with the bar in the front, and seated rotation test in softball position players with or without a history of shoulder or elbow injury. Cross-sectional design. University softball facilities. Sixty-five female National Collegiate Athletic Association Division I softball position players. Trunk-rotation flexibility was measured with 3 clinical tests. Recent injury history was obtained using a questionnaire and verified by the certified athletic trainer. Binomial regression models were used to determine if injury history was associated with flexibility categories (high, normal, or limited tertiles) for each of the 6 (3 tests × 2 directions) trunk-rotation flexibility measures. Trunk-rotation flexibility measures from 3 clinical tests were compared between participants with and without a history of shoulder or elbow injury using analysis-of-variance models. When measured using the half-kneeling rotation test with the bar in the back and the seated rotation test, injury history and forward trunk-rotation flexibility were associated. However, no mean group differences were seen in trunk-rotation flexibility between participants with and without a history of shoulder or elbow injury. Limited forward trunk-rotation flexibility may be a risk factor for shoulder or elbow injuries. However, further study is needed to confirm the study finding.

  11. Stress field rotation or block rotation: An example from the Lake Mead fault system

    NASA Technical Reports Server (NTRS)

    Ron, Hagai; Nur, Amos; Aydin, Atilla

    1990-01-01

    The Coulomb criterion, as applied by Anderson (1951), has been widely used as the basis for inferring paleostresses from in situ fault slip data, assuming that faults are optimally oriented relative to the tectonic stress direction. Consequently if stress direction is fixed during deformation so must be the faults. Freund (1974) has shown that faults, when arranged in sets, must generally rotate as they slip. Nur et al., (1986) showed how sufficiently large rotations require the development of new sets of faults which are more favorably oriented to the principal direction of stress. This leads to the appearance of multiple fault sets in which older faults are offset by younger ones, both having the same sense of slip. Consequently correct paleostress analysis must include the possible effect of fault and material rotation, in addition to stress field rotation. The combined effects of stress field rotation and material rotation were investigated in the Lake Meade Fault System (LMFS) especially in the Hoover Dam area. Fault inversion results imply an apparent 60 degrees clockwise (CW) rotation of the stress field since mid-Miocene time. In contrast structural data from the rest of the Great Basin suggest only a 30 degrees CW stress field rotation. By incorporating paleomagnetic and seismic evidence, the 30 degrees discrepancy can be neatly resolved. Based on paleomagnetic declination anomalies, it is inferred that slip on NW trending right lateral faults caused a local 30 degrees counter-clockwise (CCW) rotation of blocks and faults in the Lake Mead area. Consequently the inferred 60 degrees CW rotation of the stress field in the LMFS consists of an actual 30 degrees CW rotation of the stress field (as for the entire Great Basin) plus a local 30 degrees CCW material rotation of the LMFS fault blocks.

  12. Stress field rotation or block rotation: An example from the Lake Mead fault system

    NASA Astrophysics Data System (ADS)

    Ron, Hagai; Nur, Amos; Aydin, Atilla

    1990-02-01

    The Coulomb criterion, as applied by Anderson (1951), has been widely used as the basis for inferring paleostresses from in situ fault slip data, assuming that faults are optimally oriented relative to the tectonic stress direction. Consequently if stress direction is fixed during deformation so must be the faults. Freund (1974) has shown that faults, when arranged in sets, must generally rotate as they slip. Nur et al., (1986) showed how sufficiently large rotations require the development of new sets of faults which are more favorably oriented to the principal direction of stress. This leads to the appearance of multiple fault sets in which older faults are offset by younger ones, both having the same sense of slip. Consequently correct paleostress analysis must include the possible effect of fault and material rotation, in addition to stress field rotation. The combined effects of stress field rotation and material rotation were investigated in the Lake Meade Fault System (LMFS) especially in the Hoover Dam area. Fault inversion results imply an apparent 60 degrees clockwise (CW) rotation of the stress field since mid-Miocene time. In contrast structural data from the rest of the Great Basin suggest only a 30 degrees CW stress field rotation. By incorporating paleomagnetic and seismic evidence, the 30 degrees discrepancy can be neatly resolved. Based on paleomagnetic declination anomalies, it is inferred that slip on NW trending right lateral faults caused a local 30 degrees counter-clockwise (CCW) rotation of blocks and faults in the Lake Mead area. Consequently the inferred 60 degrees CW rotation of the stress field in the LMFS consists of an actual 30 degrees CW rotation of the stress field (as for the entire Great Basin) plus a local 30 degrees CCW material rotation of the LMFS fault blocks.

  13. Effect of forearm axially rotated posture on shoulder load and shoulder abduction / flexion angles in one-armed arrest of forward falls.

    PubMed

    Hsu, Hsiu-Hao; Chou, You-Li; Lou, Shu-Zon; Huang, Ming-Jer; Chou, Paul Pei-Hsi

    2011-03-01

    Falling onto the outstretched hand is the most common cause of upper extremity injury. This study develops an experimental model for evaluating the shoulder load during a simulated forward fall onto one hand with three different forearm axially rotated postures, and examines the shoulder abduction angle and shoulder flexion angle in each case. Fifteen healthy young male subjects with an average age of 23.7 years performed a series of one-armed arrests from a height of 5 cm onto a force plate. The kinematics and kinetics of the upper extremity were analyzed for three different forearm postures, namely 45° externally rotated, non-rotated, and 45° internally rotated. The shoulder joint load and shoulder abduction/flexion angles were significantly dependent on the rotational posture of the forearm. The shoulder medio-lateral shear forces in the externally rotated group were found to be 1.61 and 2.94 times higher than those in the non-rotated and internally rotated groups, respectively. The shoulder flexion angles in the externally rotated, non-rotated and internally rotated groups were 0.6°, 8.0° and 19.2°, respectively, while the corresponding shoulder abduction angles were 6.1°, 34.1° and 46.3°, respectively. In falls onto the outstretched hand, an externally rotated forearm posture should be avoided in order to reduce the medio-lateral shear force acting on the shoulder joint. In falls of this type, a 45° internally rotated forearm posture represents the most effective fall strategy in terms of minimizing the risk of upper extremity injuries. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. On the experimental prediction of the stability threshold speed caused by rotating damping

    NASA Astrophysics Data System (ADS)

    Vervisch, B.; Derammelaere, S.; Stockman, K.; De Baets, P.; Loccufier, M.

    2016-08-01

    An ever increasing demand for lighter rotating machinery and higher operating speeds results in a raised probability of instabilities. Rotating damping is one of the reasons, instability occurs. Rotating damping, or rotor internal damping, is the damping related to all rotating parts while non-rotating damping appearing in the non-rotating parts. The present study describes a rotating setup, designed to investigate rotating damping experimentally. An efficient experimental procedure is presented to predict the stability threshold of a rotating machine. The setup consists of a long thin shaft with a disk in the middle and clamped boundary conditions. The goal is to extract the system poles as a function of the rotating speed. The real parts of these poles are used to construct the decay rate plot, which is an indication for the stability. The efficiency of the experimental procedure relies on the model chosen for the rotating shaft. It is shown that the shaft behavior can be approximated by a single degree of freedom model that incorporates a speed dependent damping. As such low measurement effort and only one randomly chosen measurement location are needed to construct the decay rate plot. As an excitation, an automated impact hammer is used and the response is measured by eddy current probes. The proposed method yields a reliable prediction of the stability threshold speed which is validated through measurements.

  15. M Dwarf Rotation from the K2 Young Clusters to the Field. I. A Mass-Rotation Correlation at 10 Myr

    NASA Astrophysics Data System (ADS)

    Somers, Garrett; Stauffer, John; Rebull, Luisa; Cody, Ann Marie; Pinsonneault, Marc

    2017-12-01

    Recent observations of the low-mass (0.1-0.6 {M}⊙ ) rotation distributions of the Pleiades and Praesepe clusters have revealed a ubiquitous correlation between mass and rotation, such that late M dwarfs rotate an order-of-magnitude faster than early M dwarfs. In this paper, we demonstrate that this mass-rotation correlation is present in the 10 Myr Upper Scorpius association, as revealed by new K2 rotation measurements. Using rotational evolution models, we show that the low-mass rotation distribution of the 125 Myr Pleiades cluster can only be produced if it hosted an equally strong mass-rotation correlation at 10 Myr. This suggests that physical processes important in the early pre-main sequence (PMS; star formation, accretion, disk-locking) are primarily responsible for the M dwarf rotation morphology, and not quirks of later angular momentum (AM) evolution. Such early mass trends must be taken into account when constructing initial conditions for future studies of stellar rotation. Finally, we show that the average M star loses ˜25%-40% of its AM between 10 and 125 Myr, a figure accurately and generically predicted by modern solar-calibrated wind models. Their success rules out a lossless PMS and validates the extrapolation of magnetic wind laws designed for solar-type stars to the low-mass regime at early times.

  16. Patellofemoral pain and asymmetrical hip rotation.

    PubMed

    Cibulka, Michael T; Threlkeld-Watkins, Julie

    2005-11-01

    Patellofemoral joint problems are the most common overuse injury of the lower extremity, and altered femoral or hip rotation may play a role in patellofemoral pain. The purpose of this case report is to describe the evaluation of and intervention for a patient with asymmetrical hip rotation and patellofemoral pain. The patient was a 15-year-old girl with an 8-month history of anterior right knee pain, without known trauma or injury. Prior to intervention, her score on the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) was 24%. Right hip medial (internal) rotation was less than left hip medial rotation, and manual muscle testing showed weakness of the right hip internal rotator and abductor muscles. The intervention was aimed at increasing right hip medial rotation, improving right hip muscle strength (eg, the muscle force exerted by a muscle or a group of muscles to overcome a resistance), and eliminating anterior right knee pain. After 6 visits (14 days), passive left and right hip medial rotations were symmetrical, and her right hip internal rotator and abductor muscle grades were Good plus. Her WOMAC score was 0%. The patient had right patellofemoral pain and an uncommon pattern of asymmetrical hip rotation, with diminished hip medial rotation and excessive hip lateral (external) rotation on the right side. The patient's outcomes suggest that femoral or hip joint asymmetry may be related to patellofemoral joint pain.

  17. Cognitive profile of patients with rotated drawing at copy or recall: a controlled group study.

    PubMed

    Molteni, Federica; Traficante, Debora; Ferri, Francesca; Isella, Valeria

    2014-03-01

    When copying or recalling a figure from memory, some patient with dementia or focal brain lesions may rotate the drawing through ±90° or 180°. We have tried to clarify the nature of this phenomenon by investigating the cognitive profile of 22 patients who rotated the copy of the Rey-Osterrieth Complex Figure and 27 who rotated (only) the recall, and two control groups of cases with the same neuropsychiatric diagnoses, but no misorientation deficit. Brain MRI and FDG-PET images were also analysed. Predictor of rotation at the copy versus rotation at the recall was visuospatial impairment as measured by the copy of the Rey Figure; predictors of rotation at the copy versus no rotation were, again, visuospatial deficits, in addition to an abnormal performance at the task of selective attention. No specific profile of cognitive impairment distinguished patients with and without rotation at the recall. Disproportionate temporo-parieto-occipital atrophy or hypometabolism were evident in cases with misorientation of the copy, while predominant frontal abnormalities were found in cases of rotated recall. Based on these findings, rotated drawing at the copy is interpreted as a dorsal visual stream deficit, whose occurrence is more probable when attentional control is impaired. Rotation at recall seems to have a distinct, more anterior, neural substrate, but its dysexecutive nature has yet to be demonstrated. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Impact of rotation angle on crawling and non-crawling 9-month-old infants' mental rotation ability.

    PubMed

    Gerhard, Theresa M; Schwarzer, Gudrun

    2018-06-01

    The current study investigated whether 9-month-old infants' mental rotation performance was influenced by the magnitude of the angle of object rotation and their crawling ability. A total of 76 infants were tested; of these infants, 39 had been crawling for an average of 9.0 weeks. Infants were habituated to a video of a simplified Shepard-Metzler object (Shepard & Metzler, 1971), always rotating forward through a 180° angle around the horizontal axis of the object. After habituation, in two different test conditions, infants were presented with test videos of the same object rotating farther forward through a previously unseen 90° angle and with a test video of its mirror image. The two test conditions differed in the magnitude of the gap between the end of the habituation rotations and the beginning of the test rotations. The gaps were 0° and 54°. The results revealed that the mental rotation performance was influenced by the magnitude of the gaps only for the crawling infants. Their response showed significant transition from a preference for the mirror object rotations toward a preference for the familiar habituation object rotations. Thus, the results provide first evidence that it is easier for 9-month-old crawling infants to mentally rotate an object along a small angle compared with a large one. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Mental Rotation: Cross-Task Training and Generalization

    ERIC Educational Resources Information Center

    Stransky, Debi; Wilcox, Laurie M.; Dubrowski, Adam

    2010-01-01

    It is well established that performance on standard mental rotation tasks improves with training (Peters et al., 1995), but thus far there is little consensus regarding the degree of transfer to other tasks which also involve mental rotation. In Experiment 1, we assessed the effect of mental rotation training on participants' Mental Rotation Test…

  20. Instability of counter-rotating stellar disks

    NASA Astrophysics Data System (ADS)

    Hohlfeld, R. G.; Lovelace, R. V. E.

    2015-09-01

    We use an N-body simulation, constructed using GADGET-2, to investigate an accretion flow onto an astrophysical disk that is in the opposite sense to the disk's rotation. In order to separate dynamics intrinsic to the counter-rotating flow from the impact of the flow onto the disk, we consider an initial condition in which the counter-rotating flow is in an annular region immediately exterior the main portion of the astrophysical disk. Such counter-rotating flows are seen in systems such as NGC 4826 (known as the "Evil Eye Galaxy"). Interaction between the rotating and counter-rotating components is due to two-stream instability in the boundary region. A multi-armed spiral density wave is excited in the astrophysical disk and a density distribution with high azimuthal mode number is excited in the counter-rotating flow. Density fluctuations in the counter-rotating flow aggregate into larger clumps and some of the material in the counter-rotating flow is scattered to large radii. Accretion flow processes such as this are increasingly seen to be of importance in the evolution of multi-component galactic disks.

  1. Attitudes towards rotating shift work in clinical nurses: a Q-methodology study.

    PubMed

    Ha, Eun-Ho

    2015-09-01

    To identify clinical nurses' attitudes towards rotating shift work. Many hospitals worldwide employ rotating shift work patterns to staff their facilities. Attitudes of clinical nurses towards rotating shift work vary. To understand clinical nurses' attitudes towards rotating shift work, Q-methodology, a method for the analysis of subjective viewpoints with the strengths of both qualitative and quantitative methods, was used. Forty-six selected Q-statements from each of the 39 participants were classified into a normal distribution using an 11-point bipolar scale. The collected data were analysed using pc-QUANL program. Three discrete factors emerged as follows: factor I (rotating shift work is frustrating: objectionable perspective), factor II (rotating shift work is satisfactory: constructive perspective) and factor III (rotating shift work is problematic, but necessary: ambivalent perspective). The subjective viewpoints of the three identified factors can be applied in developing various roster designs for nurses engaging in rotating shift work. The findings provide the baseline for nurse leaders in helping nurses adjust and deal with rotating shift work. © 2015 John Wiley & Sons Ltd.

  2. A Computational Model of Afterimage Rotation in the Peripheral Drift Illusion Based on Retinal ON/OFF Responses

    PubMed Central

    Hayashi, Yuichiro; Ishii, Shin; Urakubo, Hidetoshi

    2014-01-01

    Human observers perceive illusory rotations after the disappearance of circularly repeating patches containing dark-to-light luminance. This afterimage rotation is a very powerful phenomenon, but little is known about the mechanisms underlying it. Here, we use a computational model to show that the afterimage rotation can be explained by a combination of fast light adaptation and the physiological architecture of the early visual system, consisting of ON- and OFF-type visual pathways. In this retinal ON/OFF model, the afterimage rotation appeared as a rotation of focus lines of retinal ON/OFF responses. Focus lines rotated clockwise on a light background, but counterclockwise on a dark background. These findings were consistent with the results of psychophysical experiments, which were also performed by us. Additionally, the velocity of the afterimage rotation was comparable with that observed in our psychophysical experiments. These results suggest that the early visual system (including the retina) is responsible for the generation of the afterimage rotation, and that this illusory rotation may be systematically misinterpreted by our high-level visual system. PMID:25517906

  3. Towards the automatic detection and analysis of sunspot rotation

    NASA Astrophysics Data System (ADS)

    Brown, Daniel S.; Walker, Andrew P.

    2016-10-01

    Torsional rotation of sunspots have been noted by many authors over the past century. Sunspots have been observed to rotate up to the order of 200 degrees over 8-10 days, and these have often been linked with eruptive behaviour such as solar flares and coronal mass ejections. However, most studies in the literature are case studies or small-number studies which suffer from selection bias. In order to better understand sunspot rotation and its impact on the corona, unbiased large-sample statistical studies are required (including both rotating and non-rotating sunspots). While this can be done manually, a better approach is to automate the detection and analysis of rotating sunspots using robust methods with well characterised uncertainties. The SDO/HMI instrument provide long-duration, high-resolution and high-cadence continuum observations suitable for extracting a large number of examples of rotating sunspots. This presentation will outline the analysis of SDI/HMI data to determine the rotation (and non-rotation) profiles of sunspots for the complete duration of their transit across the solar disk, along with how this can be extended to automatically identify sunspots and initiate their analysis.

  4. Modal testing of a rotating wind turbine

    NASA Astrophysics Data System (ADS)

    Carne, T. G.; Nord, A. R.

    1982-11-01

    A testing technique was developed to measure the modes of vibration of a rotating vertical-axis wind turbine. This technique was applied to the Sandia Two-Meter Turbine, where the changes in individual modal frequencies as a function of the rotational speed were tracked from 0 rpm (parked) to 600 rpm. During rotational testing, the structural response was measured using a combination of strain gages and accelerometers, passing the signals through slip rings. Excitation of the turbine structure was provided by a scheme which suddenly released a pretensioned cable, thus plucking the turbine as it was rotating at a set speed. In addition to calculating the real modes of the parked turbine, the modes of the rotating turbine were also determined at several rotational speeds. The modes of the rotating system proved to be complex due to centrifugal and Coriolis effects. The modal data for the parked turbine were used to update a finite-element model. Also, the measured modal parameters for the rotating turbine were compared to the analytical results, thus verifying the analytical procedures used to incorporate the effects of the rotating coordinate system.

  5. Spin Chirality of Cu3 and V3 Nanomagnets. 1. Rotation Behavior of Vector Chirality, Scalar Chirality, and Magnetization in the Rotating Magnetic Field, Magnetochiral Correlations.

    PubMed

    Belinsky, Moisey I

    2016-05-02

    The rotation behavior of the vector chirality κ, scalar chirality χ, and magnetization M in the rotating magnetic field H1 is considered for the V3 and Cu3 nanomagnets, in which the Dzialoshinsky-Moriya coupling is active. The polar rotation of the field H1 of the given strength H1 results in the energy spectrum characterized by different vector and scalar chiralities in the ground and excited states. The magnetochiral correlations between the vector and scalar chiralities, energy, and magnetization in the rotating field were considered. Under the uniform polar rotation of the field H1, the ground-state chirality vector κI performs sawtooth oscillations and the magnetization vector MI performs the sawtooth oscillating rotation that is accompanied by the correlated transformation of the scalar chirality χI. This demonstrates the magnetochiral effect of the joint rotation behavior and simultaneous frustrations of the spin chiralities and magnetization in the rotating field, which are governed by the correlation between the chiralities and magnetization.

  6. REVIEWS OF TOPICAL PROBLEMS: The differential rotation of stars

    NASA Astrophysics Data System (ADS)

    Kitchatinov, Leonid L.

    2005-05-01

    Astronomical observations of recent years have substantially extended our knowledge of the rotation of stars. Helioseismology has found out that the equator-to-pole decline in the angular velocity observed on the solar surface traces down to the deep interior of the Sun. New information has been gained regarding the dependence of the rotational nonuniformities on the angular velocity and mass of the star. These achievements have prompted the development of the theory of differential rotation, which is the focal point of this review. Nonuniform rotation results from the interaction of turbulent convection with rotation. The investigation into the turbulent mechanisms of angular-momentum transport has reached a level at which the obtained results can serve as the basis for developing quantitative models of stellar rotation. Such models contain virtually no free parameters but closely reproduce the helioseismological data on the internal rotation of the Sun. The theoretical predictions on the differential rotation of the stars agree with observations. A brief discussion is held here on the relation between the magnetic activity of stars and the nonuniformity of their rotation and on prospects for further development of the theory.

  7. Effect of limb rotation on radiographic alignment in total knee arthroplasties.

    PubMed

    Radtke, Kerstin; Becher, Christoph; Noll, Yvonne; Ostermeier, Sven

    2010-04-01

    Even in a well-aligned total knee arthroplasty (TKA), limb rotation at the time of radiographic assessment will alter the measurement of alignment. This could influence the radiographic outcome of TKA. The purpose of this study was to evaluate the effect of limb rotation on radiographic alignment after TKA and to establish a re-calculation of this rotation by using existing radiographic landmarks. Synthetic femur and tibia (Sawbones), Inc. Vashon Island, WA) were used to create a TKA of the Triathlon knee prosthesis system (Stryker), Limerick, Ireland). The femoral alignment was 6.5 degrees valgus. The model was fixed in an upright stand. Five series of nine anteroposterior (AP) long leg radiographs were taken on a 30 cm x 120 cm plates in full extension with the limb rotated, in 5 degrees increments, from 20 degrees external rotation to 20 degrees internal rotation. After digitizing each radiograph (Scanner Hewlett Packard XJ 527), an observer measured the anatomic mechanical angle of the femur [AMA ( degrees )], the mechanical lateral proximal femur angle [mLPFA ( degrees )], the mechanical lateral distal femur angle [mLDFA ( degrees )], the mechanical medial proximal tibia angle [mMPTA ( degrees )] and the mechanical lateral distal tibia angle [mLDTA ( degrees )] using a digital measurement software (MediCAD, Hectec, Altfraunhofen, Germany). Besides, the observer measured the geometrical distances of the femoral component figured on the long leg radiograph. A ratio of one distance to another was measured (called femoral component distance ratio). The average radiographic anatomic alignment ranged from 6.827 degrees AMA (SD = 0.22 degrees ) in 20 degrees internal rotation to 4.627 degrees AMA (SD = 0.22 degrees ) in 20 degrees external rotation. Average mLPFA ( degrees ) ranged from 101.63 degrees (SD = 0.63) in 20 degrees internal rotation to 93.60 degrees (SD = 0.74 degrees ) in 20 degrees external rotation. Average mLDFA ( degrees ) ranged from 90.59 degrees (SD = 3.01 degrees ) in 20 degrees internal rotation to 86.76 degrees (SD = 0.36 degrees ) in 20 degrees external rotation. Average mMPTA ( degrees ) ranged from 90.35 degrees (SD = 0.81 degrees ) in 20 degrees internal rotation to 88.49 degrees (SD = 0.52 degrees ) in 20 degrees external rotation. Average mLDTA ( degrees ) ranged from 98.89 degrees (SD = 2.3 degrees ) in 20 degrees internal rotation to 90.53 degrees (SD = 3.39 degrees ) in 20 degrees external rotation. Without an application of limb rotation, the femoral component distance ratio was measured to be 0.89 (SD = 0.01), in 20 degrees internal rotation 0.63 (SD = 0.01) and in 20 degrees external rotation 1.16 (SD = 0.01). Limb rotation had a highly statistically significant effect on measured anatomic alignment and mechanical angles. A correlation between limb rotation, anatomic mechanical angle, mechanical angles measured at femur and tibia and the femoral component distance ratio was established. As the anatomic mechanical angle and the femoral component distance ratio change linearly in the range of 20 degrees internal and external limb rotation, a calculation of the femoral component distance ratio could be used to re-calculate the limb rotation at the time of radiographic assessment to evaluate the evidence of a long leg radiograph.

  8. Immobilization in External Rotation Versus Internal Rotation After Primary Anterior Shoulder Dislocation: A Meta-analysis of Randomized Controlled Trials.

    PubMed

    Whelan, Daniel B; Kletke, Stephanie N; Schemitsch, Geoffrey; Chahal, Jaskarndip

    2016-02-01

    The recurrence rate after primary anterior shoulder dislocation is high, especially in young, active individuals. Recent studies have suggested external rotation immobilization as a method to reduce the rate of recurrent shoulder dislocation in comparison to traditional sling immobilization. To assess and summarize evidence from randomized controlled trials on the effect of internal rotation versus external rotation immobilization on the rate of recurrence after primary anterior shoulder dislocation. Meta-analysis. PubMed, MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, and abstracts from recent proceedings were searched for eligible studies. Two reviewers selected studies for inclusion, assessed methodological quality, and extracted data. Six randomized controlled trials (632 patients) were included in this review. Demographic and prognostic variables measured at baseline were similar in the pooled groups. The average age was 30.1 years in the pooled external rotation group and 30.3 years in the pooled internal rotation group. Two studies found that external rotation immobilization reduced the rate of recurrence after initial anterior shoulder dislocation compared with conventional internal rotation immobilization, whereas 4 studies failed to find a significant difference between the 2 groups. This meta-analysis suggested no overall significant difference in the rate of recurrence among patients treated with internal rotation versus external rotation immobilization (risk ratio, 0.69; 95% CI, 0.42-1.14; P = .15). There was no significant difference in the rate of compliance between internal and external rotation immobilization (P = .43). The Western Ontario Shoulder Instability Index scores were pooled across 3 studies, and there was no significant difference between the 2 groups (P = .54). Immobilization in external rotation is not significantly more effective in reducing the recurrence rate after primary anterior shoulder dislocation than immobilization in internal rotation. Additionally, this review suggests that there is minimal difference in patients' perceptions of their health-related quality of life after immobilization in internal versus external rotation. © 2015 The Author(s).

  9. Dynamical Model for Spindown of Solar-type Stars

    NASA Astrophysics Data System (ADS)

    Sood, Aditi; Kim, Eun-jin; Hollerbach, Rainer

    2016-12-01

    After their formation, stars slow down their rotation rates by the removal of angular momentum from their surfaces, e.g., via stellar winds. Explaining how this rotation of solar-type stars evolves in time is currently an interesting but difficult problem in astrophysics. Despite the complexity of the processes involved, a traditional model, where the removal of angular momentum by magnetic fields is prescribed, has provided a useful framework to understand observational relations between stellar rotation, age, and magnetic field strength. Here, for the first time, a spindown model is proposed where loss of angular momentum by magnetic fields evolves dynamically, instead of being prescibed kinematically. To this end, we evolve the stellar rotation and magnetic field simultaneously over stellar evolution time by extending our previous work on a dynamo model which incorporates nonlinear feedback mechanisms on rotation and magnetic fields. We show that our extended model reproduces key observations and is capable of explaining the presence of the two branches of (fast and slow rotating) stars which have different relations between rotation rate Ω versus time (age), magnetic field strength | B| versus rotation rate, and frequency of magnetic field {ω }{cyc} versus rotation rate. For fast rotating stars we find that: (I) there is an exponential spindown {{Ω }}\\propto {e}-1.35t, with t measured in Gyr; (II) magnetic activity saturates for higher rotation rate; (III) {ω }{cyc}\\propto {{{Ω }}}0.83. For slow rotating stars we find: (I) a power-law spindown {{Ω }}\\propto {t}-0.52; (II) that magnetic activity scales roughly linearly with rotation rate; (III) {ω }{cyc}\\propto {{{Ω }}}1.16. The results obtained from our investigations are in good agreement with observations. The Vaughan-Preston gap is consistently explained in our model by the shortest spindown timescale in this transition from fast to slow rotators. Our results highlight the importance of self-regulation of magnetic fields and rotation by direct and indirect interactions involving nonlinear feedback in stellar evolution.

  10. AC electric field induced dipole-based on-chip 3D cell rotation.

    PubMed

    Benhal, Prateek; Chase, J Geoffrey; Gaynor, Paul; Oback, Björn; Wang, Wenhui

    2014-08-07

    The precise rotation of suspended cells is one of the many fundamental manipulations used in a wide range of biotechnological applications such as cell injection and enucleation in nuclear transfer (NT) cloning. Noticeably scarce among the existing rotation techniques is the three-dimensional (3D) rotation of cells on a single chip. Here we present an alternating current (ac) induced electric field-based biochip platform, which has an open-top sub-mm square chamber enclosed by four sidewall electrodes and two bottom electrodes, to achieve rotation about the two axes, thus 3D cell rotation. By applying an ac potential to the four sidewall electrodes, an in-plane (yaw) rotating electric field is generated and in-plane rotation is achieved. Similarly, by applying an ac potential to two opposite sidewall electrodes and the two bottom electrodes, an out-of-plane (pitch) rotating electric field is generated and rolling rotation is achieved. As a prompt proof-of-concept, bottom electrodes were constructed with transparent indium tin oxide (ITO) using the standard lift-off process and the sidewall electrodes were constructed using a low-cost micro-milling process and then assembled to form the chip. Through experiments, we demonstrate rotation of bovine oocytes of ~120 μm diameter about two axes, with the capability of controlling the rotation direction and the rate for each axis through control of the ac potential amplitude, frequency, and phase shift, and cell medium conductivity. The maximum observed rotation rate reached nearly 140° s⁻¹, while a consistent rotation rate reached up to 40° s⁻¹. Rotation rate spectra for zona pellucida-intact and zona pellucida-free oocytes were further compared and found to have no effective difference. This simple, transparent, cheap-to-manufacture, and open-top platform allows additional functional modules to be integrated to become a more powerful cell manipulation system.

  11. Self-gravitational instability of dense degenerate viscous anisotropic plasma with rotation

    NASA Astrophysics Data System (ADS)

    Sharma, Prerana; Patidar, Archana

    2017-12-01

    The influence of finite Larmor radius correction, tensor viscosity and uniform rotation on self-gravitational and firehose instabilities is discussed in the framework of the quantum magnetohydrodynamic and Chew-Goldberger-Low (CGL) fluid models. The general dispersion relation is obtained for transverse and longitudinal modes of propagation. In both the modes of propagation the dispersion relation is further analysed with respect to the direction of the rotational axis. In the analytical discussion the axis of rotation is considered in parallel and in the perpendicular direction to the magnetic field. (i) In the transverse mode of propagation, when rotation is parallel to the direction of the magnetic field, the Jeans instability criterion is affected by the rotation, finite Larmor radius (FLR) and quantum parameter but remains unaffected due to the presence of tensor viscosity. The calculated critical Jeans masses for rotating and non-rotating dense degenerate plasma systems are \\odot $ and \\odot $ respectively. It is clear that the presence of rotation enhances the threshold mass of the considered system. (ii) In the case of longitudinal mode of propagation when rotation is parallel to the direction of the magnetic field, Alfvén and viscous self-gravitating modes are obtained. The Alfvén mode is modified by FLR corrections and rotation. The analytical as well as graphical results show that the presence of FLR and rotation play significant roles in stabilizing the growth rate of the firehose instability by suppressing the parallel anisotropic pressure. The viscous self-gravitating mode is significantly affected by tensor viscosity, anisotropic pressure and the quantum parameter while it remains free from rotation and FLR corrections. When the direction of rotation is perpendicular to the magnetic field, the rotation of the considered system coupled the Alfvén and viscous self-gravitating modes to each other. The finding of the present work is applicable to strongly magnetized dense degenerate plasma.

  12. Hip Rotation Range of Motion in People With and Without Low Back Pain Who Participate in Rotation-Related Sports

    PubMed Central

    Van Dillen, Linda R.; Bloom, Nancy J.; Gombatto, Sara P.; Susco, Thomas M.

    2008-01-01

    Objective To examine whether passive hip rotation motion was different between people with and without low back pain (LBP) who regularly participate in sports that require repeated rotation of the trunk and hips. We hypothesized that people with LBP would have less total hip rotation motion and more asymmetry of motion between sides than people without LBP. Design Two group, case-control. Setting University-based musculoskeletal analysis laboratory. Participants Forty-eight subjects (35 males, 13 females; mean age: 26.56±7.44 years) who reported regular participation in a rotation-related sport participated. Two groups were compared; people with LBP (N=24) and people without LBP (N=24; NoLBP). Main outcome measures Data were collected on participant-related, LBP-related, sport-related and activity-related variables. Measures of passive hip rotation range of motion were obtained. The differences between the LBP and NoLBP groups were examined. Results People with and without a history of LBP were the same with regard to all participant-related, sport-related and activity-related variables. The LBP group had significantly less total rotation (P=.035) and more asymmetry of total rotation, right hip versus left hip, (P=.022) than the NoLBP group. Left total hip rotation was more limited than right total hip rotation in the LBP group (P=.004). There were no significant differences in left and right total hip rotation for the NoLBP group (P=.323). Conclusions Among people who participate in rotation-related sports, those with LBP had less overall passive hip rotation motion and more asymmetry of rotation between sides than people without LBP. These findings suggest that the specific directional demands imposed on the hip and trunk during regularly performed activities may be an important consideration in deciding which impairments may be most relevant to test and to consider in prevention and intervention strategies. PMID:19081817

  13. A life-cycle model for wave-dominated tidal inlets along passive margin coasts of North America

    NASA Astrophysics Data System (ADS)

    Seminack, Christopher T.; McBride, Randolph A.

    2018-03-01

    A regional overview of 107 wave-dominated tidal inlets along the U.S. Atlantic coast, U.S. Gulf of Mexico coast, and Canadian Gulf of St. Lawrence coast yielded a generalized wave-dominated tidal inlet life-cycle model that recognized the rotational nature of tidal inlets. Tidal inlets are influenced by concurrently acting processes transpiring over two timescales: short-term, event-driven processes and long-term, evolutionary processes. Wave-dominated tidal inlets are classified into three rotational categories based on net longshore sediment transport direction and rotation direction along the landward (back-barrier) portion of the inlet channel: downdrift channel rotation, updrift channel rotation, or little-to-no channel rotation. Lateral shifting of the flood-tidal delta depocenter in response to available estuarine accommodation space appears to control inlet channel rotation. Flood-tidal delta deposits fill accommodation space locally within the estuary (i.e., creating bathymetric highs), causing the tidal-inlet channel to rotate. External influences, such as fluvial discharge, pre-existing back-barrier channels, and impeding salt marsh will also influence inlet-channel rotation. Storm events may rejuvenate the tidal inlet by scouring sediment within the flood-tidal delta, increasing local accommodation space. Wave-dominated tidal inlets are generally unstable and tend to open, concurrently migrate laterally and rotate, infill, and close. Channel rotation is a primary reason for wave-dominated tidal inlet closure. During rotation, the inlet channel lengthens and hydraulic efficiency decreases, thus causing tidal prism to decrease. Tidal prism, estuarine accommodation space, and sediment supply to the flood-tidal delta are the primary variables responsible for tidal inlet rotation. Stability of wave-dominated tidal inlets is further explained by: stability (S) = tidal prism (Ω) + estuarine accommodation space (V) - volume of annual sediment supply (Mt). Rotating wave-dominated tidal inlets follow a six-stage evolutionary model; whereas wave-dominated tidal inlets that exhibit little-to-no rotation follow a five-stage evolutionary model.

  14. Electro-hydrodynamic propulsion of counter-rotating Pickering drops

    NASA Astrophysics Data System (ADS)

    Dommersnes, P.; Mikkelsen, A.; Fossum, J. O.

    2016-07-01

    Insulating particles or drops suspended in carrier liquids may start to rotate with a constant frequency when subjected to a uniform DC electric field. This is known as the Quincke rotation electro-hydrodynamic instability. A single isolated rotating particle exhibit no translational motion at low Reynolds number, however interacting rotating particles may move relative to one another. Here we present a simple system consisting of two interacting and deformable Quincke rotating particle covered drops, i.e. deformable Pickering drops. The drops attract one another and spontaneously form a counter-rotating pair that exhibits electro-hydrodynamic driven propulsion at low Reynolds number flow.

  15. Effect of rotating electric field on 3D complex (dusty) plasma

    NASA Astrophysics Data System (ADS)

    Wörner, L.; Nosenko, V.; Ivlev, A. V.; Zhdanov, S. K.; Thomas, H. M.; Morfill, G. E.; Kroll, M.; Schablinski, J.; Block, D.

    2011-06-01

    The effect of rotating electric field on 3D particle clusters suspended in rf plasma was studied experimentally. Spheroidal clusters were suspended inside a glass box mounted on the lower horizontal rf electrode, with gravity partially balanced by thermophoretic force. Clusters rotated in the horizontal plane, in response to rotating electric field that was created inside the box using conducting coating on its inner surfaces ("rotating wall" technique). Cluster rotation was always in the direction of applied field and had a shear in the vertical direction. The angular speed of rotation was 104-107 times lower than applied frequency. The experiment is compared to a recent theory.

  16. Rotator cuff problems

    MedlinePlus

    ... smooth layer) lining these tendons. A rotator cuff tear occurs when one of the tendons is torn ... Poor posture over many years Aging Rotator cuff tears TEARS Rotator cuff tears may occur in two ...

  17. Paleomagnetic constraints on the interpretation of early Cenozoic Pacific Northwest paleogeography

    USGS Publications Warehouse

    Wells, Ray E.

    1984-01-01

    Widespread Cenozoic clockwise tectonic rotation in the Pacific Northwest is an established fact; however, the geologic reconstructions based on these rotations are the subject of continuing debate. Three basic mechanisms have been proposed to explain the rotations: (1) simple shear rotation of marginal terranes caught in the dextral shear couple between oceanic plates and North America; (2) rotation during oblique microplate collision and accretion to the continental margin; and (3) rotation of continental margin areas during episodes of intracontinental extension. In areas where detailed structure and stratigraphy are available, distributed shear rotations are amplv demonstrated paleomagnetically. However, rotation due to asymmetric interarc extension must be significant, especially for the Oregon Coast Range, in light of recent estimates of large Tertiary extension across the northern Basin and Range. The relative importance of shear versus extension is difficult to determine, but shear could account for nearly onehalf of the observed rotations. Oblique microplate collision has not contributed significantly to the observed Cenozoic rotations because most of the rotation post-dates collision-related deformation in the Oregon and Washington. Coast Range. The resultant continental reconstructions suggest that about 300 km of extension has occurred at 42°N. latitude (southern Oregon border) since early Eocene time. This reconstruction suggests that Cretaceous sedimentary basins east of the Klamath Mountains have undergone significant Tertiary extension (about f<0%) , but little rotation. Upper Cretaceous sedimentary rocks in the Blue Mountains of Oregon near Mitchell are probably rotated at least 15° and perhaps as much as 60°, which allows considerable latitude in the restoration of that part of the basin.

  18. Three-dimensional numerical investigation of vortex-induced vibration of a rotating circular cylinder in uniform flow

    NASA Astrophysics Data System (ADS)

    Munir, Adnan; Zhao, Ming; Wu, Helen; Lu, Lin; Ning, Dezhi

    2018-05-01

    The vortex-induced vibration (VIV) of an elastically mounted rotating circular cylinder vibrating in a uniform flow is studied numerically. The cylinder is allowed to vibrate only in the cross-flow direction. In the numerical simulations, the Reynolds number, the mass ratio, and the damping ratio are kept constants to 500, 11.5, and 0, respectively. Simulations are performed for rotation rates of α = 0, 0.5, and 1 and a range of reduced velocities from 1 to 13, which covers the entire lock-in regime. It is found that the lock-in regime of a rotating cylinder is wider than that of a non-rotating cylinder for α = 0, 0.5, and 1. The vortex shedding pattern of a rotating cylinder is found to be similar to that of a non-rotating cylinder. Next, simulations are performed for three typical reduced velocities inside the lock-in regime and a range of higher rotation rates from α = 1.5 to 3.5 to investigate the effect of the rotation rate on the suppression of VIV. It is found that the VIV is suppressed when the rotation rate exceeds a critical value, which is dependent on the reduced velocity. For a constant reduced velocity, the amplitude of the vibration is found to increase with increasing rotation rate until the latter reaches its critical value for VIV suppression, beyond which the vibration amplitude becomes extremely small. If the rotation rate is greater than its critical value, vortex shedding ceases and hairpin vortices are observed due to the rotation of the cylinder.

  19. Rotating-disk sorptive extraction: effect of the rotation mode of the extraction device on mass transfer efficiency.

    PubMed

    Jachero, Lourdes; Ahumada, Inés; Richter, Pablo

    2014-05-01

    The extraction device used in rotating-disk sorptive extraction consists of a Teflon disk in which a sorptive phase is fixed on one of its surfaces. Depending on the configuration, the rotation axis of the disk device can be either perpendicular or parallel to its radius, giving rise to two different mass transfer patterns when rotating-disk sorptive extraction is applied in liquid samples. In the perpendicular case (configuration 1), which is the typical configuration, the disk contains an embedded miniature stir bar that allows the disk rotation to be driven using a common laboratory magnetic stirrer. In the parallel case (configuration 2), the disk is driven by a rotary rod connected to an electric stirrer. In this study, triclosan and its degradation product methyl triclosan were used as analyte models to demonstrate the significant effect of the rotation configuration of the disk on the efficiency of analyte mass transfer from water to a sorptive phase of polydimethylsiloxane. Under the same experimental conditions and at a rotation velocity of 1,250 rpm, extraction equilibrium was reached at 80 min when the disk was rotated in configuration 1 and at 30 min when the disk was rotated in configuration 2. The extraction equilibration time decreased to 14 min when the rotation velocity was increased to 2,000 rpm in configuration 2. Because the rotation pattern affects the mass transfer efficiency, each rotation configuration was characterized through the Reynolds number; Re values of 6,875 and 16,361 were achieved with configurations 1 and 2, respectively, at 1,250 rpm.

  20. Speed control system for an access gate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bzorgi, Fariborz M

    2012-03-20

    An access control apparatus for an access gate. The access gate typically has a rotator that is configured to rotate around a rotator axis at a first variable speed in a forward direction. The access control apparatus may include a transmission that typically has an input element that is operatively connected to the rotator. The input element is generally configured to rotate at an input speed that is proportional to the first variable speed. The transmission typically also has an output element that has an output speed that is higher than the input speed. The input element and the outputmore » element may rotate around a common transmission axis. A retardation mechanism may be employed. The retardation mechanism is typically configured to rotate around a retardation mechanism axis. Generally the retardation mechanism is operatively connected to the output element of the transmission and is configured to retard motion of the access gate in the forward direction when the first variable speed is above a control-limit speed. In many embodiments the transmission axis and the retardation mechanism axis are substantially co-axial. Some embodiments include a freewheel/catch mechanism that has an input connection that is operatively connected to the rotator. The input connection may be configured to engage an output connection when the rotator is rotated at the first variable speed in a forward direction and configured for substantially unrestricted rotation when the rotator is rotated in a reverse direction opposite the forward direction. The input element of the transmission is typically operatively connected to the output connection of the freewheel/catch mechanism.« less

  1. Mental rotation of tactile stimuli: using directional haptic cues in mobile devices.

    PubMed

    Gleeson, Brian T; Provancher, William R

    2013-01-01

    Haptic interfaces have the potential to enrich users' interactions with mobile devices and convey information without burdening the user's visual or auditory attention. Haptic stimuli with directional content, for example, navigational cues, may be difficult to use in handheld applications; the user's hand, where the cues are delivered, may not be aligned with the world, where the cues are to be interpreted. In such a case, the user would be required to mentally transform the stimuli between different reference frames. We examine the mental rotation of directional haptic stimuli in three experiments, investigating: 1) users' intuitive interpretation of rotated stimuli, 2) mental rotation of haptic stimuli about a single axis, and 3) rotation about multiple axes and the effects of specific hand poses and joint rotations. We conclude that directional haptic stimuli are suitable for use in mobile applications, although users do not naturally interpret rotated stimuli in any one universal way. We find evidence of cognitive processes involving the rotation of analog, spatial representations and discuss how our results fit into the larger body of mental rotation research. For small angles (e.g., less than 40 degree), these mental rotations come at little cost, but rotations with larger misalignment angles impact user performance. When considering the design of a handheld haptic device, our results indicate that hand pose must be carefully considered, as certain poses increase the difficulty of stimulus interpretation. Generally, all tested joint rotations impact task difficulty, but finger flexion and wrist rotation interact to greatly increase the cost of stimulus interpretation; such hand poses should be avoided when designing a haptic interface.

  2. Thermal casting of polymers in centrifuge for producing X-ray optics

    DOEpatents

    Hill, Randy M [Livermore, CA; Decker, Todd A [Livermore, CA

    2012-03-27

    An optic is produced by the steps of placing a polymer inside a rotateable cylindrical chamber, the rotateable cylindrical chamber having an outside wall, rotating the cylindrical chamber, heating the rotating chamber forcing the polymer to the outside wall of the cylindrical chamber, allowing the rotateable cylindrical chamber to cool while rotating producing an optic substrate with a substrate surface, sizing the optic substrate, and coating the substrate surface of the optic substrate to produce the optic with an optic surface.

  3. Vectors and Rotations in 3-Dimensions: Vector Algebra for the C++ Programmer

    DTIC Science & Technology

    2016-12-01

    Proving Ground, MD 21005-5068 This report describes 2 C++ classes: a Vector class for performing vector algebra in 3-dimensional space ( 3D ) and a Rotation...class for performing rotations of vectors in 3D . Each class is self-contained in a single header file (Vector.h and Rotation.h) so that a C...vector, rotation, 3D , quaternion, C++ tools, rotation sequence, Euler angles, yaw, pitch, roll, orientation 98 Richard Saucier 410-278-6721Unclassified

  4. Flexibility of internal and external glenohumeral rotation of junior female tennis players and its correlation with performance ranking.

    PubMed

    Chiang, Ching-Cheng; Hsu, Chih-Chia; Chiang, Jinn-Yen; Chang, Weng-Cheng; Tsai, Jong-Chang

    2016-12-01

    [Purpose] The purpose of this study was to compare the internal and external rotation of the dominant and nondominant shoulders of adolescent female tennis players. The correlation between the shoulder rotation range of motion and the player's ranking was also analyzed. [Subjects and Methods] Twenty-one female junior tennis players who were 13 to 18 years old participated in this study. A standard goniometer was used to measure the internal and external rotation of both glenohumeral joints. The difference in internal and external rotation was calculated as the glenohumeral rotation deficit. The year-end ranking of each player was obtained from the Chinese Taipei Tennis Association. [Results] The internal rotation of the dominant shoulder was significantly smaller than that of the nondominant shoulder. Moreover, player ranking was significantly and negatively correlated with the internal rotation range of motion of both shoulders. On the other hand, the correlations of the internal and external rotation ranges of motion with the age, height, and weight were not significant. [Conclusion] The flexibility of the glenohumeral internal rotation is smaller in the dominant shoulder than of the nondominant shoulder in these junior female tennis players. Flexibility of the glenohumeral internal rotation may be a factor affecting performance in junior female tennis players.

  5. Limited rotation of the mobile-bearing in a rotating platform total knee prosthesis.

    PubMed

    Garling, E H; Kaptein, B L; Nelissen, R G H H; Valstar, E R

    2007-01-01

    The hypothesis of this study was that the polyethylene bearing in a rotating platform total knee prosthesis shows axial rotation during a step-up motion, thereby facilitating the theoretical advantages of mobile-bearing knee prostheses. We examined 10 patients with rheumatoid arthritis who had a rotating platform total knee arthroplasty (NexGen LPS mobile, Zimmer Inc. Warsaw, USA). Fluoroscopic data was collected during a step-up motion six months postoperatively. A 3D-2D model fitting technique was used to reconstruct the in vivo 3D kinematics. The femoral component showed more axial rotation than the polyethylene mobile-bearing insert compared to the tibia during extension. In eight knees, the femoral component rotated internally with respect to the tibia during extension. In the other two knees the femoral component rotated externally with respect to the tibia. In all 10 patients, the femur showed more axial rotation than the mobile-bearing insert indicating the femoral component was sliding on the polyethylene of the rotating platform during the step-up motion. Possible explanations are a too limited conformity between femoral component and insert, the anterior located pivot location of the investigated rotating platform design, polyethylene on metal impingement and fibrous tissue formation between the mobile-bearing insert and the tibial plateau.

  6. A novel method of measuring spatial rotation angle using MEMS tilt sensors

    NASA Astrophysics Data System (ADS)

    Cao, Jian'an; Zhu, Xin; Wu, Hao; Zhang, Leping

    2017-10-01

    This paper presents a novel method of measuring spatial rotation angle with a dual-axis micro-electro-mechanical systems tilt sensor. When the sensor is randomly mounted on the surface of the rotating object, there are three unpredictable and unknown mounting position parameters: α, the sensor’s swing angle on the measuring plane; β, the angle between the rotation axis and the horizontal plane; and γ, the angle between the measuring plane and the rotation axis. Thus, the sensor’s spatial rotation model is established to describe the relationship between the measuring axis, rotation axis, and horizontal plane, and the corresponding analytical equations are derived. Furthermore, to eliminate the deviation caused by the uncertain direction of the rotation axis, an extra perpendicularly mounted, single-axis tilt sensor is combined with the dual-axis tilt sensor, forming a three-axis tilt sensor. Then, by measuring the sensors’ three tilts and solving the model’s equations, the object’s spatial rotation angle is obtained. Finally, experimental results show that the developed tilt sensor is capable of measuring spatial rotation angle in the range of  ±180° with an accuracy of 0.2° if the angle between the rotation axis and the horizontal plane is less than 75°.

  7. Prediction of the body rotation-induced torques on the arm during reaching movements: evidence from a proprioceptively deafferented subject.

    PubMed

    Guillaud, Etienne; Simoneau, Martin; Blouin, Jean

    2011-06-01

    Reaching for a target while rotating the trunk generates substantial Coriolis and centrifugal torques that push the arm in the opposite direction of the rotations. These torques rarely perturb movement accuracy, suggesting that they are compensated for during the movement. Here we tested whether signals generated during body motion (e.g., vestibular) can be used to predict the torques induced by the body rotation and to modify the motor commands accordingly. We asked a deafferented subject to reach for a memorized visual target in darkness. At the onset of the reaching, the patient was rotated 25° or 40° in the clockwise or the counterclockwise directions. During the rotation, the patient's head remained either fixed in space (Head-Fixed condition) or fixed on the trunk (Head Rotation condition). At the rotation onset, the deafferented patient's hand largely deviated from the mid-sagittal plane in both conditions. The hand deviations were compensated for in the Head Rotation condition only. These results highlight the computational faculty of the brain and show that body rotation-related information can be processed for predicting the consequence of the rotation dynamics on the reaching arm movements. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Rotating Casimir systems: Magnetic-field-enhanced perpetual motion, possible realization in doped nanotubes, and laws of thermodynamics

    NASA Astrophysics Data System (ADS)

    Chernodub, M. N.

    2013-01-01

    Recently, we have demonstrated that for a certain class of Casimir-type systems (“devices”) the energy of zero-point vacuum fluctuations reaches its global minimum when the device rotates about a certain axis rather than remains static. This rotational vacuum effect may lead to the emergence of permanently rotating objects provided the negative rotational energy of zero-point fluctuations cancels the positive rotational energy of the device itself. In this paper, we show that for massless electrically charged particles the rotational vacuum effect should be drastically (astronomically) enhanced in the presence of a magnetic field. As an illustration, we show that in a background of experimentally available magnetic fields the zero-point energy of massless excitations in rotating torus-shaped doped carbon nanotubes may indeed overwhelm the classical energy of rotation for certain angular frequencies so that the permanently rotating state is energetically favored. The suggested “zero-point-driven” devices—which have no internally moving parts—correspond to a perpetuum mobile of a new, fourth kind: They do not produce any work despite the fact that their equilibrium (ground) state corresponds to a permanent rotation even in the presence of an external environment. We show that our proposal is consistent with the laws of thermodynamics.

  9. Fork rotation and DNA precatenation are restricted during DNA replication to prevent chromosomal instability.

    PubMed

    Schalbetter, Stephanie A; Mansoubi, Sahar; Chambers, Anna L; Downs, Jessica A; Baxter, Jonathan

    2015-08-18

    Faithful genome duplication and inheritance require the complete resolution of all intertwines within the parental DNA duplex. This is achieved by topoisomerase action ahead of the replication fork or by fork rotation and subsequent resolution of the DNA precatenation formed. Although fork rotation predominates at replication termination, in vitro studies have suggested that it also occurs frequently during elongation. However, the factors that influence fork rotation and how rotation and precatenation may influence other replication-associated processes are unknown. Here we analyze the causes and consequences of fork rotation in budding yeast. We find that fork rotation and precatenation preferentially occur in contexts that inhibit topoisomerase action ahead of the fork, including stable protein-DNA fragile sites and termination. However, generally, fork rotation and precatenation are actively inhibited by Timeless/Tof1 and Tipin/Csm3. In the absence of Tof1/Timeless, excessive fork rotation and precatenation cause extensive DNA damage following DNA replication. With Tof1, damage related to precatenation is focused on the fragile protein-DNA sites where fork rotation is induced. We conclude that although fork rotation and precatenation facilitate unwinding in hard-to-replicate contexts, they intrinsically disrupt normal chromosome duplication and are therefore restricted by Timeless/Tipin.

  10. Rotator cuff strength in recurrent anterior shoulder instability.

    PubMed

    Edouard, Pascal; Degache, Francis; Beguin, Laurent; Samozino, Pierre; Gresta, Giorgio; Fayolle-Minon, Isabelle; Farizon, Frédéric; Calmels, Paul

    2011-04-20

    Although rotator-cuff muscle contraction plays an important role in stabilizing the glenohumeral joint, little is known about the role of these muscles in the pathophysiology of recurrent anterior instability. We intended to analyze the association between isokinetic internal rotator and external rotator muscle strength and glenohumeral joint instability in patients with recurrent anterior instability that was not previously treated surgically. We enrolled thirty-seven patients with unilateral recurrent anterior posttraumatic shoulder dislocation and eleven healthy nonathletic subjects in this controlled study. The association between internal rotator and external rotator strength and shoulder instability was analyzed by side-to-side comparisons and comparisons with a control group. Isokinetic internal rotator and external rotator strength was evaluated with a Con-Trex dynamometer, with the subject seated and the shoulder abducted 45° in the scapular plane. Tests were performed at 180°/s, 120°/s, and 60°/s in concentric mode for both sides. Peak torque normalized to body weight and external rotator to internal rotator ratio were calculated for each angular velocity. Clinical and isokinetic evaluation was done by the same rehabilitation physician. The association between shoulder instability and internal rotator and external rotator strength was associated with side-to-side differences (p < 0.05). Compared with a control group, strength values were lower on the pathological shoulder side of the patients with shoulder instability than on the healthy contralateral shoulder of control subjects at 180°/s and 120°/s (p < 0.05). The side-to-side differences were increased when the nondominant upper-extremity side was involved and were decreased when the dominant side was involved. There was no association between glenohumeral joint instability and external rotator to internal rotator ratio. Internal rotator and external rotator weakness was associated with recurrent anterior instability, and side-to-side differences depended on the side of hand dominance. Use of a control group may help in the analysis of the influence of constraints on shoulder strength. Further prospective studies are necessary to determine whether the weakness is a cause or an effect of the instability.

  11. A Bizarre, Unexplained, and Progressive External Rotation of the Shoulder as a Presentation of a Metastatic Deposit in the Rotator Cuff.

    PubMed

    El-Tawil, Sherif; Prinja, Aditya; Stanton, Jeremy

    2015-01-01

    We describe the first reported case of a tumour deposit within the rotator cuff presenting as a bizarre, progressive, and fixed external rotation deformity of the shoulder. It is also the first reported case to our knowledge of an oesophageal primary metastasising to the rotator cuff.

  12. Development of a cryogenic rotating heat pipe joint

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The performance of two critical technology components required for a continuously rotatable heat pipe: (1) a low-leakage rotatable coupling for the heat pipe pressure vessel, and (2) a rotatable internal wick, is reported. Performance and leakage requirements were established based on 12 months operation of a cryogenic rotatable heat pipe on a satellite in earth orbit.

  13. The Nature of Relationships between Mental Rotation, Math, and Language in Deaf Signers

    ERIC Educational Resources Information Center

    Halper, Elizabeth Blaisdell

    2009-01-01

    Three mental rotation tasks, the Card Rotation Task (CRT), the Vandenberg Mental Rotation Test (VMRT), and the Money Road-Map of Direction Sense (MRM), were administered to 60 deaf students from Gallaudet University to determine if mental rotation was predictive of scores on the ACT English or Math subtests. Other predictor variables, such as…

  14. Sex differences on a computerized mental rotation task disappear with computer familiarization.

    PubMed

    Roberts, J E; Bell, M A

    2000-12-01

    The area of cognitive research that has produced the most consistent sex differences is spatial ability. Particularly, men consistently perform better on mental rotation tasks than do women. This study examined the effects of familiarization with a computer on performance of a computerized two-dimensional mental rotation task. Two groups of college students (N=44) performed the rotation task, with one group performing a color-matching task that allowed them to be familiarized with the computer prior to the rotation task. Among the participants who only performed the rotation task, the 11 men performed better than the 11 women. Among the participants who performed the computer familiarization task before the rotation task, how ever, there were no sex differences on the mental rotation task between the 10 men and 12 women. These data indicate that sex differences on this two-dimensional task may reflect familiarization with the computer, not the mental rotation component of the task. Further research with larger samples and increased range of task difficulty is encouraged.

  15. Is it possible to re-establish pre-operative patellar kinematics using a ligament-balanced technique in total knee arthroplasty? A cadaveric investigation.

    PubMed

    Keshmiri, Armin; Springorum, Hans; Baier, Clemens; Zeman, Florian; Grifka, Joachim; Maderbacher, Günther

    2015-03-01

    Several authors emphasise that the appearance of patellar maltracking after total knee arthroplasty (TKA) is caused by rotational malalignment of the femoral and tibial components. Ligament-balanced femoral component rotation was not found to be associated with abnormal postoperative patellar position. We hypothesised that a ligament-balanced technique in TKA has the ability to best re-establish patellar kinematics. In ten cadaveric knees TKA was performed assessing femoral rotation in ligament-balanced and different femoral and tibial component rotation alignments. Patellar kinematics after different component rotations were analysed using a commercial computer navigation system. Ligament-balanced femoral rotation showed the best re-establishment of patellar kinematics after TKA compared to the healthy pre-operative knee. In contrast to tibial component rotation, femoral component rotation had a major impact on patellofemoral kinematics. This investigation suggests that a ligament-balanced technique in TKA is most likely to re-establish natural patellofemoral kinematics. Tibial component rotation did not influence patellar kinematics.

  16. Flux density measurement of radial magnetic bearing with a rotating rotor based on fiber Bragg grating-giant magnetostrictive material sensors.

    PubMed

    Ding, Guoping; Zhang, Songchao; Cao, Hao; Gao, Bin; Zhang, Biyun

    2017-06-10

    The rotational magnetic field of radial magnetic bearings characterizes remarkable time and spatial nonlinearity due to the eddy current and induced electromagnetic field. It is significant to experimentally obtain the features of the rotational magnetic field of the radial magnetic bearings to validate the theoretical analysis and reveal the discipline of a rotational magnetic field. This paper developed thin-slice fiber Bragg grating-giant magnetostrictive material (FBG-GMM) magnetic sensors to measure air-gap flux density of a radial magnetic bearing with a rotating rotor; a radial magnetic bearing test rig was constructed and the rotational magnetic field with different rotation speed was measured. Moreover, the finite element method (FEM) was used to simulate the rotational magnetic field; the measurement results and FEM results were investigated, and it was concluded that the FBG-GMM sensors were capable of measuring the radial magnetic bearing's air gap flux density with a rotating rotor, and the measurement results showed a certain degree of accuracy.

  17. Constraining movement alters the recruitment of motor processes in mental rotation.

    PubMed

    Moreau, David

    2013-02-01

    Does mental rotation depend on the readiness to act? Recent evidence indicates that the involvement of motor processes in mental rotation is experience-dependent, suggesting that different levels of expertise in sensorimotor interactions lead to different strategies to solve mental rotation problems. Specifically, experts in motor activities perceive spatial material as objects that can be acted upon, triggering covert simulation of rotations. Because action simulation depends on the readiness to act, movement restriction should therefore disrupt mental rotation performance in individuals favoring motor processes. In this experiment, wrestlers and non-athletes judged whether pairs of three-dimensional stimuli were identical or different, with their hands either constrained or unconstrained. Wrestlers showed higher performance than controls in the rotation of geometric stimuli, but this difference disappeared when their hands were constrained. However, movement restriction had similar consequences for both groups in the rotation of hands. These findings suggest that expert's advantage in mental rotation of abstract objects is based on the readiness to act, even when physical manipulation is impossible.

  18. Edge localized mode rotation and the nonlinear dynamics of filaments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morales, J. A.; Bécoulet, M.; Garbet, X.

    2016-04-15

    Edge Localized Modes (ELMs) rotating precursors were reported few milliseconds before an ELM crash in several tokamak experiments. Also, the reversal of the filaments rotation at the ELM crash is commonly observed. In this article, we present a mathematical model that reproduces the rotation of the ELM precursors as well as the reversal of the filaments rotation at the ELM crash. Linear ballooning theory is used to establish a formula estimating the rotation velocity of ELM precursors. The linear study together with nonlinear magnetohydrodynamic simulations give an explanation to the rotations observed experimentally. Unstable ballooning modes, localized at the pedestal,more » grow and rotate in the electron diamagnetic direction in the laboratory reference frame. Approaching the ELM crash, this rotation decreases corresponding to the moment when the magnetic reconnection occurs. During the highly nonlinear ELM crash, the ELM filaments are cut from the main plasma due to the strong sheared mean flow that is nonlinearly generated via the Maxwell stress tensor.« less

  19. KEPLER RAPIDLY ROTATING GIANT STARS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Costa, A. D.; Martins, B. L. Canto; Bravo, J. P.

    2015-07-10

    Rapidly rotating giant stars are relatively rare and may represent important stages of stellar evolution, resulting from stellar coalescence of close binary systems or accretion of substellar companions by their hosting stars. In the present Letter, we report 17 giant stars observed in the scope of the Kepler space mission exhibiting rapid rotation behavior. For the first time, the abnormal rotational behavior for this puzzling family of stars is revealed by direct measurements of rotation, namely from photometric rotation period, exhibiting a very short rotation period with values ranging from 13 to 55 days. This finding points to remarkable surfacemore » rotation rates, up to 18 times the rotation of the Sun. These giants are combined with six others recently listed in the literature for mid-infrared (IR) diagnostics based on Wide-field Infrared Survey Explorer information, from which a trend for an IR excess is revealed for at least one-half of the stars, but at a level far lower than the dust excess emission shown by planet-bearing main-sequence stars.« less

  20. Actuator assembly including a single axis of rotation locking member

    DOEpatents

    Quitmeyer, James N.; Benson, Dwayne M.; Geck, Kellan P.

    2009-12-08

    An actuator assembly including an actuator housing assembly and a single axis of rotation locking member fixedly attached to a portion of the actuator housing assembly and an external mounting structure. The single axis of rotation locking member restricting rotational movement of the actuator housing assembly about at least one axis. The single axis of rotation locking member is coupled at a first end to the actuator housing assembly about a Y axis and at a 90.degree. angle to an X and Z axis providing rotation of the actuator housing assembly about the Y axis. The single axis of rotation locking member is coupled at a second end to a mounting structure, and more particularly a mounting pin, about an X axis and at a 90.degree. angle to a Y and Z axis providing rotation of the actuator housing assembly about the X axis. The actuator assembly is thereby restricted from rotation about the Z axis.

  1. The Unruh effect for eccentric uniformly rotating observers

    NASA Astrophysics Data System (ADS)

    Ramezani-Aval, H.

    It is common to use Galilean rotational transformation (GRT) to investigate the Unruh effect for uniformly rotating observers. However, the rotating observer in this subject is an eccentric observer while GRT is only valid for centrally rotating observers. Thus, the reliability of the results of applying GRT to the study of the Unruh effect might be considered as questionable. In this work, the rotational analog of the Unruh effect is investigated by employing two relativistic rotational transformations corresponding to the eccentric rotating observer, and it is shown that in both cases, the detector response function is nonzero. It is also shown that although consecutive Lorentz transformations cannot give a frame within which the canonical construction can be carried out, the expectation value of particle number operator in canonical approach will be zero if we use modified Franklin transformation. These conclusions reinforce the claim that correspondence between vacuum states defined via canonical field theory and a detector is broken for rotating observers. Some previous conclusions are commented on and some controversies are also discussed.

  2. Staff rotation: implications for occupational therapy.

    PubMed

    Taylor, A; Andriuk, M L; Langlois, P; Provost, E

    1995-10-01

    Occupational therapy departments of tertiary care hospitals can provide staff with opportunities to gain diverse clinical experience if they rotate through the various services such as surgery, medicine, geriatrics, plastic surgery and orthopaedics. The system of rotation offers both advantages and disadvantages for the staff and the institution. The Royal Victoria Hospital in Montreal, a large university teaching hospital, had traditionally offered staff the opportunity to rotate. Changes in staffing and their needs however, resulted in rotation becoming an important issue within the department. This article presents the pros and the cons of rotation and non-rotation systems as identified by therapists and administrators across Canada. Staff rotation was found to have an effect on job satisfaction and a therapist's career orientation. Given these findings, administrators may want to reconsider the role of the generalist and specialist in their facilities.

  3. The rotational elements of Mars and its satellites

    NASA Astrophysics Data System (ADS)

    Jacobson, R. A.; Konopliv, A. S.; Park, R. S.; Folkner, W. M.

    2018-03-01

    The International Astronomical Union (IAU) defines planet and satellite coordinate systems relative to their axis of rotation and the angle about that axis. The rotational elements of the bodies are the right ascension and declination of the rotation axis in the International Celestial Reference Frame and the rotation angle, W, measured easterly along the body's equator. The IAU specifies the location of the body's prime meridian by providing a value for W at epoch J2000. We provide new trigonometric series representations of the rotational elements of Mars and its satellites, Phobos and Deimos. The series for Mars are from a least squares fit to the rotation model used to orient the Martian gravity field. The series for the satellites are from a least squares fit to rotation models developed in accordance with IAU conventions from recent ephemerides.

  4. Functional form for plasma velocity in a rapidly rotating tokamak discharge

    DOE PAGES

    Burrell, Keith H.; Chrystal, C. olin

    2014-07-25

    A recently developed technique using charge exchange spectroscopy determines the ion poloidal rotation in tokamak plasmas from the poloidal variation in the toroidal angular rotation speed. The basis for this technique is the functional form for the plasma velocity calculated from the equilibrium equations. The initial development of this technique utilized the functional form determined for conditions where the ion toroidal rotation speed is much smaller than the ion thermal speed. There are cases, however, where the toroidal rotation can be comparable to the ion thermal speed, especially for high atomic number impurities. Furthermore, the present paper extends the previousmore » analysis to this high rotation speed case and demonstrates how to extract the poloidal rotation speed from measurements of the toroidal angular rotation speed at two points on a flux surface.« less

  5. Potential of mechanical metamaterials to induce their own global rotational motion

    NASA Astrophysics Data System (ADS)

    Dudek, K. K.; Wojciechowski, K. W.; Dudek, M. R.; Gatt, R.; Mizzi, L.; Grima, J. N.

    2018-05-01

    The potential of several classes of mechanical metamaterials to induce their own overall rotational motion through the individual rotation of their subunits is examined. Using a theoretical approach, we confirm that for various rotating rigid unit systems, if by design the sum of angular momentum of subunits rotating in different directions is made to be unequal, then the system will experience an overall rotation, the extent of which may be controlled through careful choice of the geometric parameters defining these systems. This phenomenon of self-induced rotation is also confirmed experimentally. Furthermore, we discuss how these systems can be designed in a special way so as to permit extended rotations which allows them to overcome geometric lockage and the relevance of this concept in applications ranging from satellites to spacecraft and telescopes employed in space.

  6. The Effect of Rotation on Oscillatory Double-diffusive Convection (Semiconvection)

    NASA Astrophysics Data System (ADS)

    Moll, Ryan; Garaud, Pascale

    2017-01-01

    Oscillatory double-diffusive convection (ODDC, more traditionally called semiconvection) is a form of linear double-diffusive instability that occurs in fluids that are unstably stratified in temperature (Schwarzschild unstable), but stably stratified in chemical composition (Ledoux stable). This scenario is thought to be quite common in the interiors of stars and giant planets, and understanding the transport of heat and chemical species by ODDC is of great importance to stellar and planetary evolution models. Fluids unstable to ODDC have a tendency to form convective thermocompositional layers that significantly enhance the fluxes of temperature and chemical composition compared with microscopic diffusion. Although a number of recent studies have focused on studying properties of both layered and nonlayered ODDC, few have addressed how additional physical processes such as global rotation affect its dynamics. In this work, we study first how rotation affects the linear stability properties of rotating ODDC. Using direct numerical simulations, we then analyze the effect of rotation on properties of layered and nonlayered ODDC, and we study how the angle of the rotation axis with respect to the direction of gravity affects layering. We find that rotating systems can be broadly grouped into two categories based on the strength of rotation. The qualitative behavior in the more weakly rotating group is similar to nonrotating ODDC, but strongly rotating systems become dominated by vortices that are invariant in the direction of the rotation vector and strongly influence transport. We find that whenever layers form, rotation always acts to reduce thermal and compositional transport.

  7. Defensive Abdominal Rotation Patterns of Tenebrionid Beetle, Zophobas atratus, Pupae

    PubMed Central

    Ichikawa, Toshio; Nakamura, Tatsuya; Yamawaki, Yoshifumi

    2012-01-01

    Exarate pupae of the beetle Zophobas atratus Fab. (Coleoptera: Tenebrionidae) have free appendages (antenna, palp, leg, and elytron) that are highly sensitive to mechanical stimulation. A weak tactile stimulus applied to any appendage initiated a rapid rotation of abdominal segments. High-speed photography revealed that one cycle of defensive abdominal rotation was induced in an all-or-none fashion by bending single or multiple mechanosensory hairs on a leg or prodding the cuticular surface of appendages containing campaniform sensilla. The direction of the abdominal rotation completely depended on the side of stimulation; stimulation of a right appendage induced a right-handed rotation about the anterior-posterior axis of the pupal body and vice versa. The trajectories of the abdominal rotations had an ellipsoidal or pear-shaped pattern. Among the trajectory patterns of the rotations induced by stimulating different appendages, there were occasional significant differences in the horizontal (right-left) component of abdominal rotational movements. Simultaneous stimulation of right and left appendages often induced variable and complex patterns of abdominal movements, suggesting an interaction between sensory signals from different sides. When an abdominal rotation was induced in a freely lying pupa, the rotation usually made the pupa move away from or turn its dorsum toward the source of stimulation with the aid of the caudal processes (urogomphi), which served as a fulcrum for transmitting the power of the abdominal rotation to the movement or turning of the whole body. Pattern generation mechanisms for the abdominal rotation were discussed. PMID:23448289

  8. Asymmetrical perception of body rotation after unilateral injury to human vestibular cortex.

    PubMed

    Philbeck, John W; Behrmann, Marlene; Biega, Tim; Levy, Lucien

    2006-01-01

    Vestibular information plays a key role in many perceptual and cognitive functions, but surprisingly little is known about how vestibular signals are processed at the cortical level in humans. To address this issue, we tested the ability of two patients, with damage to key components of the vestibular network in either the left or right hemisphere, to perceive passive whole-body rotations (25-125 degrees) about the yaw axis. In both patients, the posterior insula, hippocampus, putamen, and thalamus were extensively damaged. The patients' responses were compared with those of nine age- and sex-matched neurologically intact participants. The body rotations were conducted without vision and the peak angular velocities ranged from 40 degrees to 90 degrees per second. Perceived rotation was assessed by open-loop manual pointing. The right hemisphere patient exhibited poor sensitivity for body rotations toward the contralesional (left) hemispace and generally underestimated the rotations. By contrast, his judgments of rotations toward the ipsilesional (right) hemispace greatly overestimated the physical rotation by 50-70 degrees for all tested magnitudes. The left hemisphere patient's responses were more appropriately scaled for both rotation directions, falling in the low-normal range. These findings suggest that there is some degree of hemispheric specialization in the cortical processing of dynamic head rotations in the yaw plane. In this view, right hemisphere structures play a dominant role, processing rotations in both directions, while left hemisphere structures process rotations only toward the contralesional hemispace.

  9. Defensive abdominal rotation patterns of tenebrionid beetle, Zophobas atratus, pupae.

    PubMed

    Ichikawa, Toshio; Nakamura, Tatsuya; Yamawaki, Yoshifumi

    2012-01-01

    Exarate pupae of the beetle Zophobas atratus Fab. (Coleoptera: Tenebrionidae) have free appendages (antenna, palp, leg, and elytron) that are highly sensitive to mechanical stimulation. A weak tactile stimulus applied to any appendage initiated a rapid rotation of abdominal segments. High-speed photography revealed that one cycle of defensive abdominal rotation was induced in an all-or-none fashion by bending single or multiple mechanosensory hairs on a leg or prodding the cuticular surface of appendages containing campaniform sensilla. The direction of the abdominal rotation completely depended on the side of stimulation; stimulation of a right appendage induced a right-handed rotation about the anterior-posterior axis of the pupal body and vice versa. The trajectories of the abdominal rotations had an ellipsoidal or pear-shaped pattern. Among the trajectory patterns of the rotations induced by stimulating different appendages, there were occasional significant differences in the horizontal (right-left) component of abdominal rotational movements. Simultaneous stimulation of right and left appendages often induced variable and complex patterns of abdominal movements, suggesting an interaction between sensory signals from different sides. When an abdominal rotation was induced in a freely lying pupa, the rotation usually made the pupa move away from or turn its dorsum toward the source of stimulation with the aid of the caudal processes (urogomphi), which served as a fulcrum for transmitting the power of the abdominal rotation to the movement or turning of the whole body. Pattern generation mechanisms for the abdominal rotation were discussed.

  10. Influence of fixation point of latissimus dorsi tendon transfer for irreparable rotator cuff tear on glenohumeral external rotation: A cadaver study.

    PubMed

    Bargoin, K; Boissard, M; Kany, J; Grimberg, J

    2016-12-01

    Latissimus dorsi tendon transfer is a surgical option for treating irreparable posterosuperior rotator cuff tears, notably when attempting to reconstruct active external rotation. We hypothesized that the positioning of the transfer's point of fixation would differ depending on the desired elbow-to-body external rotation or external rotation with the elbow abducted. Seven shoulders from four whole frozen cadavers were used. We created two systems to install the subject in a semi-seated position to allow external rotation elbow to body and the arm abducted 90°. Traction sutures were positioned on the latissimus dorsi muscle and a massive tear of the rotator cuff was created. We tested six different transfer positions. Muscle contraction of the latissimus dorsi was stimulated using 10-N and 20-N suspended weights. The point of fixation of the latissimus dorsi on the humeral head had an influence on the elbow-to-body external rotation and with 90° abduction (P<0.001). The fixation point for a maximum external rotation with the elbow to the body was the anterolateral position (P<0.016). The fixation point for a maximum external rotation at 90° abduction was the position centered on the infraspinatus footprint (P<0.078). The optimal point of fixation differs depending on whether external rotation is restored at 0° or 90° abduction. Fundamental study, anatomic study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  11. Neovascularization prevalence in the supraspinatus of patients with rotator cuff tendinopathy.

    PubMed

    Kardouni, Joseph R; Seitz, Amee L; Walsworth, Matthew K; Michener, Lori A

    2013-11-01

    A high prevalence of neovascularity in lower extremity tendinopathies has been reported. Neovascularity in those with rotator cuff tendinopathy exclusively has not been examined. The objective was to determine the prevalence of neovascularization in patients with rotator cuff tendinopathy compared with asymptomatic controls. Single-blind cross-sectional study. Research laboratory. Participants (n = 40; age = 44.9 years, 23-62 years; 20 females) with rotator cuff tendinopathy (n = 20) but without full-thickness rotator cuff tears, and asymptomatic controls that were age, gender, and hand dominance matched (n = 20) to the patients. The participants laying in supine had their shoulder positioned in internal rotation and extension. Ultrasound images were collected of the supraspinatus tendon and subacromial bursae in the transverse and longitudinal planes using a linear transducer in color Doppler mode. Images were assessed for neovascularization by 2 trained raters who were blinded to group (rotator cuff tendinopathy or asymptomatic group). No statistically significant difference in neovascularization was identified between participants with and without rotator cuff tendinopathy (χ = 0.13, df = 1, P = 0.72). Neovascularization was identified in 6 of 20 patients with rotator cuff tendinopathy (30%) and 5 of 20 asymptomatic control participants (25%). The authors found no differences in neovascularization rate in patients with rotator cuff tendinopathy (30%) and asymptomatic controls (25%). The study indicates that neovascularization is not related to presence of symptomatic tendinopathy in those with rotator cuff tendinopathy. Neovascularization may not be a relevant sonographic finding to aid the clinical assessment of those with rotator cuff tendinopathy.

  12. Inertial measurement unit using rotatable MEMS sensors

    DOEpatents

    Kohler, Stewart M [Albuquerque, NM; Allen, James J [Albuquerque, NM

    2007-05-01

    A MEM inertial sensor (e.g. accelerometer, gyroscope) having integral rotational means for providing static and dynamic bias compensation is disclosed. A bias compensated MEM inertial sensor is described comprising a MEM inertial sense element disposed on a rotatable MEM stage. A MEM actuator drives the rotation of the stage between at least two predetermined rotational positions. Measuring and comparing the output of the MEM inertial sensor in the at least two rotational positions allows for both static and dynamic bias compensation in inertial calculations based on the sensor's output. An inertial measurement unit (IMU) comprising a plurality of independently rotatable MEM inertial sensors and methods for making bias compensated inertial measurements are disclosed.

  13. Inertial measurement unit using rotatable MEMS sensors

    DOEpatents

    Kohler, Stewart M.; Allen, James J.

    2006-06-27

    A MEM inertial sensor (e.g. accelerometer, gyroscope) having integral rotational means for providing static and dynamic bias compensation is disclosed. A bias compensated MEM inertial sensor is described comprising a MEM inertial sense element disposed on a rotatable MEM stage. A MEM actuator for drives the rotation of the stage between at least two predetermined rotational positions. Measuring and comparing the output of the MEM inertial sensor in the at least two rotational positions allows, for both static and dynamic bias compensation in inertial calculations based on the sensor's output. An inertial measurement unit (IMU) comprising a plurality of independently rotatable MEM inertial sensors and methods for making bias compensated inertial measurements are disclosed.

  14. Teaching and learning in an 80-hour work week: a novel day-float rotation for medical residents.

    PubMed

    Wong, Jeffrey G; Holmboe, Eric S; Huot, Stephen J

    2004-05-01

    The 80-hour workweek limit for residents provides an opportunity for residency directors to creatively innovate their programs. Our novel day-float rotation augmented both the educational structure within the inpatient team setting and the ability for house staff to complete their work within the mandated limits. Descriptive evaluation of the rotation was performed through an end-of-rotation questionnaire. The average length of the ward residents' work week was quantified before and after the rotation's implementation. Educational portfolios and mentored peer-teaching opportunities enriched the rotation. As measured by our evaluation, this new rotation enhanced learning and patient care while reducing work hours for inpatient ward residents.

  15. Algorithmic support for graphic images rotation in avionics

    NASA Astrophysics Data System (ADS)

    Kniga, E. V.; Gurjanov, A. V.; Shukalov, A. V.; Zharinov, I. O.

    2018-05-01

    The avionics device designing has an actual problem of development and research algorithms to rotate the images which are being shown in the on-board display. The image rotation algorithms are a part of program software of avionics devices, which are parts of the on-board computers of the airplanes and helicopters. Images to be rotated have the flight location map fragments. The image rotation in the display system can be done as a part of software or mechanically. The program option is worse than the mechanic one in its rotation speed. The comparison of some test images of rotation several algorithms is shown which are being realized mechanically with the program environment Altera QuartusII.

  16. NMR system and method having a permanent magnet providing a rotating magnetic field

    DOEpatents

    Schlueter, Ross D [Berkeley, CA; Budinger, Thomas F [Berkeley, CA

    2009-05-19

    Disclosed herein are systems and methods for generating a rotating magnetic field. The rotating magnetic field can be used to obtain rotating-field NMR spectra, such as magic angle spinning spectra, without having to physically rotate the sample. This result allows magic angle spinning NMR to be conducted on biological samples such as live animals, including humans.

  17. A Bizarre, Unexplained, and Progressive External Rotation of the Shoulder as a Presentation of a Metastatic Deposit in the Rotator Cuff

    PubMed Central

    El-Tawil, Sherif; Prinja, Aditya; Stanton, Jeremy

    2015-01-01

    We describe the first reported case of a tumour deposit within the rotator cuff presenting as a bizarre, progressive, and fixed external rotation deformity of the shoulder. It is also the first reported case to our knowledge of an oesophageal primary metastasising to the rotator cuff. PMID:26543658

  18. Assessment of Dominant/Codominant Height Growth for Second Rotation Slash Pine Plantations in South Georgia and North Florida

    Treesearch

    Charles E. Rose; Barry D. Shiver

    2002-01-01

    A slash pine (Pinus elliottii Engelm.) successive rotation plantation study was established in 1978-79 for the north Florida and south Georgia fiatwoods. The second rotation duplicated the first rotation seed source, site preparation, planting method, and density. The comparison between the two rotations is based on the mean height differential...

  19. Influence of a rural family medicine rotation on residency selection: MS3 versus MS4.

    PubMed

    Geske, Jenenne A; Hartman, Teresa; Goodman, Barbara; Paulman, Paul

    2011-09-01

    Many family medicine educators feel that a required clinical rotation in family medicine has a positive influence on medical students' selection of family medicine residencies. We investigated the effect of a rural family medicine rotation on students' residency choices and examined the differences between a third-year and a fourth-year rotation. We surveyed 1,260 students before and after they participated in a required rural family medicine rotation. The rotation had a small positive effect on student interest in family medicine. Over 20 years, there was a net gain of 4.7% (93 students) from before to after the rotation. Moving the rural rotation from the MS4 to the MS3 year resulted in a significant decline in the number of students who switched their preferences toward family medicine and ultimately matched to a family medicine residency. When the rotation occurs in the third year, there is more time following the rotation for other influences to exert an impact on a student's specialty choice, resulting in a small "bleed" away from family medicine. It might be useful to develop programs that continue to pique the interest in family medicine during their fourth year.

  20. Dynamic behaviour of a rotating cracked beam

    NASA Astrophysics Data System (ADS)

    Yashar, Ahmed; Ghandchi-Tehrani, Maryam; Ferguson, Neil

    2016-09-01

    This paper presents a new approach to investigate and analyse the vibrational behaviour of cracked rotating cantilever beams, which can for example represent helicopter or wind turbine blades. The analytical Hamiltonian method is used in modelling the rotating beam and two numerical methods, the Rayleigh-Ritz and FEM, are used to study the natural frequencies and the mode shapes of the intact rotating beams. Subsequently, a crack is introduced into the FE model and simulations are performed to identify the modal characteristics for an open cracked rotating beam. The effect of various parameters such as non-dimensional rotating speed, hub ratio and slenderness ratio are investigated for both the intact and the cracked rotating beam, and in both directions of chordwise and flapwise motion. The veering phenomena in the natural frequencies as a function of the rotational speed and the buckling speed are considered with respect to the slenderness ratio. In addition, the mode shapes obtained for the flapwise vibration are compared using the modal assurance criterion (MAC). Finally, a new three dimensional design chart is produced, showing the effect of crack location and depth on the natural frequencies of the rotating beam. This chart will be subsequently important in identifying crack defects in rotating blades.

  1. Fundamentally Distributed Information Processing Integrates the Motor Network into the Mental Workspace during Mental Rotation.

    PubMed

    Schlegel, Alexander; Konuthula, Dedeepya; Alexander, Prescott; Blackwood, Ethan; Tse, Peter U

    2016-08-01

    The manipulation of mental representations in the human brain appears to share similarities with the physical manipulation of real-world objects. In particular, some neuroimaging studies have found increased activity in motor regions during mental rotation, suggesting that mental and physical operations may involve overlapping neural populations. Does the motor network contribute information processing to mental rotation? If so, does it play a similar computational role in both mental and manual rotation, and how does it communicate with the wider network of areas involved in the mental workspace? Here we used multivariate methods and fMRI to study 24 participants as they mentally rotated 3-D objects or manually rotated their hands in one of four directions. We find that information processing related to mental rotations is distributed widely among many cortical and subcortical regions, that the motor network becomes tightly integrated into a wider mental workspace network during mental rotation, and that motor network activity during mental rotation only partially resembles that involved in manual rotation. Additionally, these findings provide evidence that the mental workspace is organized as a distributed core network that dynamically recruits specialized subnetworks for specific tasks as needed.

  2. Collisionality Scaling of Main-ion Toroidal and Poloidal Rotation in Low Torque DIII-D Plasmas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    B A Grierson, et al

    In tokamak plasmas with low levels of toroidal rotation, the radial electric fi eld Er is a combination of pressure gradient and toroidal and poloidal rotation components, all having similar magnitudes. In order to assess the validity of neoclassical poloidal rotation theory for determining the poloidal rotation contribution to Er , Dα emission from neutral beam heated tokamak discharges in DIII-D [J.L. Luxon, Nucl. Fusion 42 , 614 (2002)] has been evaluated in a sequence of low torque (electron cyclotron resonance heating and balanced diagnostic neutral beam pulse) discharges to determine the local deuterium toroidal rotation velocity. By invoking themore » radial force balance relation the deuterium poloidal rotation can be inferred. It is found that the deuterium poloidal low exceeds the neoclassical value in plasmas with collisionality νi < 0: 1, being more ion diamagnetic, and with a stronger dependence on collisionality than neoclassical theory predicts. At low toroidal rotation, the poloidal rotation contribution to the radial electric fi eld and its shear is signi cant. The eff ect of anomalous levels of poloidal rotation on the radial electric fi eld and cross fi eld heat transport is investigated for ITER parameters.« less

  3. Disentangling rotational velocity distribution of stars

    NASA Astrophysics Data System (ADS)

    Curé, Michel; Rial, Diego F.; Cassetti, Julia; Christen, Alejandra

    2017-11-01

    Rotational speed is an important physical parameter of stars: knowing the distribution of stellar rotational velocities is essential for understanding stellar evolution. However, rotational speed cannot be measured directly and is instead the convolution between the rotational speed and the sine of the inclination angle vsin(i). The problem itself can be described via a Fredhoml integral of the first kind. A new method (Curé et al. 2014) to deconvolve this inverse problem and obtain the cumulative distribution function for stellar rotational velocities is based on the work of Chandrasekhar & Münch (1950). Another method to obtain the probability distribution function is Tikhonov regularization method (Christen et al. 2016). The proposed methods can be also applied to the mass ratio distribution of extrasolar planets and brown dwarfs (in binary systems, Curé et al. 2015). For stars in a cluster, where all members are gravitationally bounded, the standard assumption that rotational axes are uniform distributed over the sphere is questionable. On the basis of the proposed techniques a simple approach to model this anisotropy of rotational axes has been developed with the possibility to ``disentangling'' simultaneously both the rotational speed distribution and the orientation of rotational axes.

  4. Spatio-temporal brain activity related to rotation method during a mental rotation task of three-dimensional objects: an MEG study.

    PubMed

    Kawamichi, Hiroaki; Kikuchi, Yoshiaki; Ueno, Shoogo

    2007-09-01

    During mental rotation tasks, subjects perform mental simulation to solve tasks. However, detailed neural mechanisms underlying mental rotation of three-dimensional (3D) objects, particularly, whether higher motor areas related to mental simulation are activated, remain unknown. We hypothesized that environmental monitoring-a process based on environmental information and is included in motor execution-is as a key factor affecting the utilization of higher motor areas. Therefore, using magnetoencephalography (MEG), we measured spatio-temporal brain activities during two types (two-dimensional (2D) and 3D rotation tasks) of mental rotation of 3D objects. Only the 3D rotation tasks required subjects to mentally rotate objects in a depth plane with visualization of hidden parts of the visual stimuli by acquiring and retrieving 3D information. In cases showing significant differences in the averaged activities at 100-ms intervals between the two rotations, the activities were located in the right dorsal premotor (PMd) at approximately 500 ms. In these cases, averaged activities during 3D rotation were greater than those during 2D rotation, implying that the right PMd activities are related to environmental monitoring. During 3D rotation, higher activities were observed from 200 to 300 ms in the left PMd and from 400 to 700 ms in the right PMd. It is considered that the left PMd is related to primary motor control, whereas the right PMd plays a supplementary role during mental simulation. Further, during 3D rotation, late higher activities related to mental simulation are observed in the right superior parietal lobule (SPL), which is connected to PMd.

  5. The effect of bronchoscope rotation on tracheal tube orientation at the glottic level in a mannequin.

    PubMed

    Wong, David T; Yau, Brian; Thapar, Shikha; Adhikary, Sanjib D

    2010-10-01

    This study examined the effect of external fibreoptic bronchoscope (FOB) rotations on endotracheal tube (ETT) orientations at the glottic level. Using a mannequin, a nasal FOB was inserted for image capture. A second FOB with a preloaded ETT taped to its top was inserted orally into mid-trachea. The FOB with the taped ETT was rotated as a unit in the axial plane to five different external angles (-90°, -45°, 0°, +45°, +90°). At each external rotation, the ETT was advanced into the trachea. The image of the ETT at the glottic level was captured. Endotracheal tube orientation was quantified according to the glottic zone faced by the ETT. The ETT orientations were compared amongst the five external FOB rotations using the Kruskal-Wallis Test, while the ETT orientations at -90°, -45°, +45°, and +90° FOB rotations were compared with 0° rotation using the Mann-Whitney U test. There was a significant difference in the ETT orientations amongst the five FOB rotations (P < 0.001). The ETT orientations at -90°, -45°, +45°, and +90° FOB rotations were different from the 0° rotation (P < 0.001 for all comparisons). A -90° FOB rotation was most effective in turning the ETT tip away from the right laryngeal structures and the interarytenoid tissue. With the ETT loaded on a FOB, rotation of the FOB prior to advancing the ETT is effective in changing the ETT orientation at the glottis. A -90° FOB rotation is most effective in turning the ETT tip away from the right laryngeal structures and interarytenoid tissue.

  6. Electromyographic activity of selected scapular stabilizers during glenohumeral internal and external rotation contractions.

    PubMed

    Schachter, Aaron K; McHugh, Malachy P; Tyler, Timothy F; Kreminic, Ian J; Orishimo, Karl F; Johnson, Christopher; Ben-Avi, Simon; Nicholas, Stephen J

    2010-09-01

    An important synergistic relationship exists between the scapular stabilizers and the glenohumeral rotators. Information on the relative contribution of the scapular stabilizers to glenohumeral rotation would be useful for exercise prescription for overhead athletes and for patients with shoulder pathology. We hypothesized that the scapular stabilizers would be highly active during both maximal and submaximal internal and external rotation. Eight healthy male volunteers (16 shoulders) performed internal and external glenohumeral rotation testing at maximal and submaximal intensities. They also performed a scapular retraction rowing exercise at maximal and submaximal levels. Electromyographic (EMG) signals were recorded from the infraspinatus, pectoralis major, serratus anterior, and middle trapezius. Values were compared among muscle groups, among individual muscles at different intensity levels, and among individual muscles at different points in the arc of motion. For submaximal glenohumeral internal rotation, activity in the scapular stabilizers was not different (P = .1-.83) from activity in the internal rotator throughout the range of motion. For the initial two-thirds of maximal internal rotation, middle trapezius activity and pectoralis major activity were higher (P < .05) than serratus anterior activity. For submaximal external rotation, activity in the scapular stabilizers during the middle phase of the motion was higher (P < .05) than activity in the external rotators. For maximal external rotation these differences were present throughout the motion with middle trapezius activity exceeding 100% maximal voluntary contraction. The scapular stabilizers functioned at a similar or higher intensity than the glenohumeral rotators during internal and external rotation. This highlights the importance of training the scapular stabilizers in upper extremity athletes and in patients with shoulder pathology. (c) 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  7. Effects of underestimating the kinematics of trunk rotation on simultaneous reaching movements: predictions of a biomechanical model

    PubMed Central

    2013-01-01

    Background Rotation of the torso while reaching produces torques (e.g., Coriolis torque) that deviate the arm from its planned trajectory. To ensure an accurate reaching movement, the brain may take these perturbing torques into account during movement planning or, alternatively, it may correct hand trajectory during movement execution. Irrespective of the process selected, it is expected that an underestimation of trunk rotation would likely induce inaccurate shoulder and elbow torques, resulting in hand deviation. Nonetheless, it is still undetermined to what extent a small error in the perception of trunk rotations, translating into an inappropriate selection of motor commands, would affect reaching accuracy. Methods To investigate, we adapted a biomechanical model (J Neurophysiol 89: 276-289, 2003) to predict the consequences of underestimating trunk rotations on right hand reaching movements performed during either clockwise or counter clockwise torso rotations. Results The results revealed that regardless of the degree to which the torso rotation was underestimated, the amplitude of hand deviation was much larger for counter clockwise rotations than for clockwise rotations. This was attributed to the fact that the Coriolis and centripetal joint torques were acting in the same direction during counter clockwise rotation yet in opposite directions during clockwise rotations, effectively cancelling each other out. Conclusions These findings suggest that in order to anticipate and compensate for the interaction torques generated during torso rotation while reaching, the brain must have an accurate prediction of torso rotation kinematics. The present study proposes that when designing upper limb prostheses controllers, adding a sensor to monitor trunk kinematics may improve prostheses control and performance. PMID:23758968

  8. Translational head movements of pigeons in response to a rotating pattern: characteristics and tool to analyse mechanisms underlying detection of rotational and translational optical flow.

    PubMed

    Nalbach, H O

    1992-01-01

    Pigeons freely standing in the centre of a two-dimensionally textured cylinder not only rotate but also laterally translate their head in response to the pattern sinusoidally oscillating or unidirectionally rotating around their vertical axis. The translational head movement dominates the response at high oscillation frequencies, whereas in a unidirectionally rotating drum head translation declines at about the same rate as the rotational response increases. It is suggested that this is a consequence of charging the 'velocity storage' in the vestibulo-ocular system. Similar to the rotational head movement (opto-collic reflex), the translational head movement is elicited via a wide-field motion sensitive system. The underlying mechanism can be described as vector integration of movement vectors tangential to the pattern rotation. Stimulation of the frontal visual field elicits largest translational responses while rotational responses can be elicited equally well from any azimuthal position of a moving pattern. Experiments where most of the pattern is occluded by a screen and the pigeon is allowed to view the stimulus through one or two windows demonstrate a short-range inhibition and long-range excitation between movement detectors that feed into the rotational system. Furthermore, the results obtained from such types of experiments suggest that the rotational system inhibits the translational system. These mechanisms may help the pigeon to decompose image flow into its translational and rotational components. Because of their translational response to a rotational stimulus, it is concluded, however, that pigeons either generally cannot perfectly perform the task or they need further visual information, like differential image motion, that was not available to them in the paradigms.

  9. Can turned inward patella predict an excess of femoral anteversion during gait in spastic diplegic children?

    PubMed

    Simon, Anne-Laure; Presedo, Ana; Ilharreborde, Brice; Mallet, Cindy; Mazda, Keyvan; Penneçot, Georges-François

    2014-06-01

    Determining patellar orientation in the transverse plane during observational gait analysis is a fundamental aspect of physical examinations. Many physicians consider that an abnormal position of the patella in the transverse planes is only explained by a rotational abnormality of the proximal femur. A total of 188 spastic diplegic children with cerebral palsy were reviewed (376 lower limbs). The physical examination included observation of patellar orientation at midstride and measuring femoral anteversion (FA). All patients also underwent 3-dimensional (3D) computerized gait analysis of pelvic and hip rotation kinematics. Observational gait analysis and videotapes found 103 children (206 lower limbs) with inturned patella at midstance. Kinematic data from 3D gait analysis showed that the visual impression of turned inward patella was erroneous in 48 limbs. Of the remaining 158 lower limbs, 117 (74%) exhibited excessive FA and 41 (26%) did not. Of the 117 with excessive FA, kinematics showed only 66 (56%) with excessive internal hip rotation (with or without excessive internal pelvic rotation). Of the 41 lower limbs without excessive FA, 25 were explained by excessive internal pelvic rotation and 16 were explained by excessive internal hip rotation (isolated spasticity and/or contracture of internal rotator muscles). Turned inward patella was caused by isolated excessive internal pelvic rotation in 48%, excessive internal hip rotation in 35% (including 44 cases with excessive FA and 12 cases with isolated spasticity and/or contracture of internal hip rotators), and excessive internal hip rotation combined with excessive internal pelvic rotation in 17%. Excessive FA was not the only cause of turned inward patella gait and could not explain this gait anomaly by itself. Excessive internal pelvic rotation was the most frequent cause of turned inward patella gait. Level IV.

  10. Rotational malalignment after closed intramedullary nailing of femoral shaft fractures and its influence on daily life.

    PubMed

    Karaman, Ozgur; Ayhan, Egemen; Kesmezacar, Hayrettin; Seker, Ali; Unlu, Mehmet Can; Aydingoz, Onder

    2014-10-01

    Any intraoperative rotational malalignment during intramedullary nailing (IMN) of femoral shaft fractures will become permanent. We hypothesized that rotational malalignment of the femur and its compensatory biomechanics may induce problems in the hip, knee, patellofemoral and ankle joints. We purposed to clarify the influence of a femoral rotational malalignment of ≥10° on daily activities. Twenty-four femoral shaft fracture patients treated with closed antegrade IMN were included. At last follow-up, to reveal any rotational malalignment, computerized tomography (CT) scans of both femurs (injured and uninjured sides) were examined. The patient groups with or without CT-detected true rotational malalignment ≥10° were compared with respect to the activity scores. Ten of the 24 patients (41.7%) had a CT-detected true rotational malalignment of ≥10° compared with the unaffected side. The AOFAS scores were 100.00 for all of the patients. LKS, WOMAC knee, and WOMAC hip scores were significantly decreased in the patients with rotational malalignment compared to those without. Patients without rotational malalignment tolerated climbing stairs significantly better than those with rotational malalignment. Patients who could not tolerate climbing stairs were consistently complaining of anterior knee pain. A femoral rotational malalignment of ≥10° is symptomatic for the patients, and the hip, knee, and patellofemoral joints were affected. Because of the possibly altered joint loadings and biomechanics, these could render patients prone to degenerative joint disease. In addition, due to the high rates of rotational malalignment after femoral shaft fracture and consequent malpractice claims, it is important for surgeons to be more aware of rotational alignment during surgery.

  11. Shear-induced autorotation of freely rotatable cylinder in a channel flow at moderate Reynolds number

    NASA Astrophysics Data System (ADS)

    Xia, Yi; Lin, Jianzhong; Ku, Xiaoke; Chan, Tatleung

    2018-04-01

    Flow past a center-pinned freely rotatable cylinder asymmetrically confined in a two-dimensional channel is simulated with the lattice Boltzmann method for a range of Reynolds number 0.1 ≤ Re ≤ 200, eccentricity ratio 0/8 ≤ ɛ ≤ 7/8, and blockage ratio 0.1 ≤ β ≤ 0.5. It is found that the inertia tends to facilitate the anomalous clockwise rotation of the cylinder. As the eccentricity ratio increases, the cylinder rotates faster in the counterclockwise direction and then slows down at a range of Re < 10. At a range of Re > 40, there exists an anomalous clockwise rotation for the cylinder at a low eccentricity ratio and the domain where the cylinder rotates anomalously becomes larger with the increase in the Reynolds number. In a channel with a higher blockage ratio, the rotation of the cylinder is more sensitive to the change of cylinder lateral position, and the separatrix at which the cylinder remains a state of rest moves upward generally. The cylinder is more likely to rotate counterclockwise and the rotating velocity is larger. At a lower blockage ratio, the anomalous clockwise rotation is more likely to occur, and the largest rotating velocity occurs when the blockage ratio is equal to 0.3. The mechanism of distinct rotational behavior of the cylinder is attributed to the transformation of distribution of shear stress which is resulted from the variation of pressure drop, the shift of maximum or minimum pressure zones along the upper and lower semi-cylinder surface, and the movement of stagnant point and separate point. Finally, the effects of the cylinder rotation on the flow structure and hydrodynamic force exerted on the cylinder surface are analyzed as well.

  12. Early postoperative fluoroquinolone use is associated with an increased revision rate after arthroscopic rotator cuff repair.

    PubMed

    Cancienne, Jourdan M; Brockmeier, Stephen F; Rodeo, Scott A; Young, Chris; Werner, Brian C

    2017-07-01

    To evaluate the association of postoperative fluoroquinolone use following arthroscopic primary rotator cuff repair with failure requiring revision rotator cuff repair. An insurance database was queried for patients undergoing rotator cuff repair from 2007 to 2015. These patients were divided into three groups: (1) patients prescribed fluoroquinolones within 6 months postoperatively (divided into 0-2, 2-4, and 4-6 months), (2) a matched negative control cohort of patients not prescribed fluoroquinolones, and (3) a matched positive control cohort of patients prescribed fluoroquinolones between 6 and 18 months following rotator cuff repair. Rates of failure requiring revision rotator cuff repair were compared within 2 years. A total of 1292 patients were prescribed fluoroquinolones within 6 months after rotator cuff repair, including 442 within 2 months, 433 within 2 to 4 months, and 417 within 4 to 6 months, and were compared to 5225 matched negative controls and 1597 matched positive controls. The rate of revision rotator cuff repair was significantly higher in patients prescribed fluoroquinolones within 2 months (6.1 %) compared to matched negative (2.2 %, P = 0.0009) and positive controls (2.4 %, P = 0.0026). There were no significant differences in the rate of revision rotator cuff repair when fluoroquinolones were prescribed >2 months after rotator cuff repair. Early use of fluoroquinolones following rotator cuff repair was independently associated with significantly increased rates of failure requiring revision rotator cuff repair. This is the first clinical study examining the association of postoperative fluoroquinolone use with failure following arthroscopic rotator cuff repair. III.

  13. Determining if an axially rotated solenoid will induce a radial EMF

    NASA Astrophysics Data System (ADS)

    MacDermott, Dustin R.

    The nature of the electromagnetic field of an axially rotated solenoid or magnet is investigated. The investigations reviewed suggest the possibility of a radially emitted electric field by either: axially rotated magnetic field lines, or a relativistic change in charge of the electron. For a very long solenoid a relativistic change in charge leaves no electric field inside while leaving an electric field outside. The concept of axially rotating magnetic field lines gives an opposite prediction. They both seem to be in contradiction to the standard model of induction, which gives no change in the electric field for a rotated solenoid or magnet. An experiment by Joseph B. Tate [48], [49] conducted in 1968 seemed to have measured a change in charge outside of a rotated solenoid. Another experiment by Barnett [3] in 1912 reported measuring no electric field inside of a rotated solenoid. Further experimentation was decided necessary and the method decided upon to attempt detection of the radial E or EMF induced by an axially rotating B field or change in charge is two concentric capacitor plates, one inside and the other outside an axially rotated solenoid. The solenoid was rotated on a lathe for the test. A concentric capacitor around an axially rotated permanent neodymium magnet was also used as a test. These experiments proved very challenging because of the small magnitude of the predicted effect. Nevertheless, the bulk of the evidence obtained indicates that no induced E arises when a magnetic source is rotated about its magnetic axis, thus supporting the standard field model of electromagnetic induction, and casting doubt on the alternative theories of magnetic field line rotation or relativistic charge enhancement.

  14. AN ACTIVITY–ROTATION RELATIONSHIP AND KINEMATIC ANALYSIS OF NEARBY MID-TO-LATE-TYPE M DWARFS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    West, Andrew A.; Weisenburger, Kolby L.; Irwin, Jonathan

    Using spectroscopic observations and photometric light curves of 238 nearby M dwarfs from the MEarth exoplanet transit survey, we examine the relationships between magnetic activity (quantified by Hα emission), rotation period, and stellar age. Previous attempts to investigate the relationship between magnetic activity and rotation in these stars were hampered by the limited number of M dwarfs with measured rotation periods (and the fact that v sin i measurements probe only rapid rotation). However, the photometric data from MEarth allows us to probe a wide range of rotation periods for hundreds of M dwarf stars (from shorter than one tomore » longer than 100 days). Over all M spectral types that we probe, we find that the presence of magnetic activity is tied to rotation, including for late-type, fully convective M dwarfs. We also find evidence that the fraction of late-type M dwarfs that are active may be higher at longer rotation periods compared to their early-type counterparts, with several active, late-type, slowly rotating stars present in our sample. Additionally, we find that all M dwarfs with rotation periods shorter than 26 days (early-type; M1–M4) and 86 days (late-type; M5–M8) are magnetically active. This potential mismatch suggests that the physical mechanisms that connect stellar rotation to chromospheric heating may be different in fully convective stars. A kinematic analysis suggests that the magnetically active, rapidly rotating stars are consistent with a kinematically young population, while slow-rotators are less active or inactive and appear to belong to an older, dynamically heated stellar population.« less

  15. Does rotational strain at screw tightening affect the attainment or maintenance of osseointegration?

    PubMed

    Moriya, Katsunori; Maruo, Yukinori; Minagi, Shogo

    2006-08-01

    This study investigated whether rotational strain affects osseointegration. A total of 135 male rats were divided into five groups: 2-w rotation, 4-w rotation, 8-w rotation, 12-w rotation and control. Two hundred and seventy implants were inserted in rat tibia. The control group received no strain, while the 2-w, 4-w, 8-w and 12-w rotation groups received rotational strain at 2, 4, 8 and 12 weeks after implant placement, respectively. Removal torque (N cm) was measured in vivo. Bone contact rate (%) was calculated histomorphologically. Immunostaining for osteonectin (ON), osteopontin (OPN) and osteocalcin (OCN) was performed. The removal torque and bone contact rate were analyzed using one-way analyses of variance and the Scheffé method. At 4 weeks, the torque was significantly higher in the 2-w rotation group (1.30+/-0.44 N cm) than in the control group (0.79+/-0.67 N cm). From 8 to 16 weeks, the strained groups showed no significant differences from the control group. From the bone contact rates, bone formation was larger in the 4-week rotation group (62.9+/-10.7%) than in the control group (42.1+/-17.9%) at 8 weeks. The 4-week rotation group showed higher bone contact rate (61.1+/-11.3%) compared with the other strained groups and maintained this higher value until 16 weeks, showing no significant difference from the control group (72+/-5.2%). At the implant-bone interface, OPN was widely distributed and OCN was detected at a low level; however, ON could not be observed in any group. The bone contact rate changed when rotational strain was exerted at different periods after implant placement. However, the removal torque and distribution of extracellular matrix proteins were not adversely affected by the rotational strain.

  16. Unlocking the talus by eversion limits medial ankle injury risk during external rotation.

    PubMed

    Button, Keith D; Wei, Feng; Haut, Roger C

    2015-10-15

    Eversion prior to excessive external foot rotation has been shown to predispose the anterior tibiofibular ligament (ATiFL) to failure, yet protect the anterior deltoid ligament (ADL) from failure despite high levels of foot rotation. The purpose of the current study was to measure the rotations of both the subtalar and talocrural joints during foot external rotation at sub-failure levels in either a neutral or a pre-everted position as a first step towards understanding the mechanisms of injury in previous studies. Fourteen (seven pairs) cadaver lower extremities were externally rotated 20° in either a pre-everted or neutral configuration, without producing injury. Motion capture was performed to track the tibia, talus, and calcaneus motions, and a joint coordinate system was used to analyze motions of the two joints. While talocrural joint rotation was greater in the neutral ankle (13.3±2.0° versus 10.5±2.7°, p=0.006), subtalar joint rotation was greater in the pre-everted ankle (2.4±1.9° versus 1.1±1.0°, p=0.014). Overall, the talocrural joint rotated more than the subtalar joint (11.9±2.8° versus 1.8±1.6°, p<0.001). It was proposed that the calcaneus and talus 'lock' in a neutral position, but 'unlock' when the ankle is everted prior to rotation. This locking/unlocking mechanism could be responsible for an increased subtalar rotation, but decreased talocrural rotation when the ankle is pre-everted, protecting the ADL from failure. This study may provide information valuable to the study of external rotation kinematics and injury risk. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Broadband integrated polarization rotator using three-layer metallic grating structures

    DOE PAGES

    Fan, Ren -Hao; Liu, Dong; Peng, Ru -Wen; ...

    2018-01-05

    In this work, we demonstrate broadband integrated polarization rotator (IPR) with a series of three-layer rotating metallic grating structures. This transmissive optical IPR can conveniently rotate the polarization of linearly polarized light to any desired directions at different spatial locations with high conversion efficiency, which is nearly constant for different rotation angles. The linear polarization rotation originates from multi-wave interference in the three-layer grating structure. As a result, we anticipate that this type of IPR will find wide applications in analytical chemistry, biology, communication technology, imaging, etc.

  18. Nonuniformity of the Earth's rotation and the motion of the poles

    NASA Technical Reports Server (NTRS)

    Sidorenkov, N. S.

    1983-01-01

    The study of the nonuniformity of the Earth's rotation and the motion of the poles has great practical and theoretical significance. This study makes it possible to determine the coordinates of celestial and terrestrial objects, and to gain information in many domains of earth science. This paper reviews studies of rotation nonuniformity and polar motion, giving attention to astronomical data; the nature of periodic oscillations of the Earth's rotation; the nature of long-period variations of the Earth's rotation rate; and the use of Earth-rotation data in hydrometeorology.

  19. Broadband integrated polarization rotator using three-layer metallic grating structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan, Ren -Hao; Liu, Dong; Peng, Ru -Wen

    In this work, we demonstrate broadband integrated polarization rotator (IPR) with a series of three-layer rotating metallic grating structures. This transmissive optical IPR can conveniently rotate the polarization of linearly polarized light to any desired directions at different spatial locations with high conversion efficiency, which is nearly constant for different rotation angles. The linear polarization rotation originates from multi-wave interference in the three-layer grating structure. As a result, we anticipate that this type of IPR will find wide applications in analytical chemistry, biology, communication technology, imaging, etc.

  20. Synergic effects of 10°/s constant rotation and rotating background on visual cognitive processing

    NASA Astrophysics Data System (ADS)

    He, Siyang; Cao, Yi; Zhao, Qi; Tan, Cheng; Niu, Dongbin

    In previous studies we have found that constant low-speed rotation facilitated the auditory cognitive process and constant velocity rotation background sped up the perception, recognition and assessment process of visual stimuli. In the condition of constant low-speed rotation body is exposed into a new physical state. In this study the variations of human brain's cognitive process under the complex condition of constant low-speed rotation and visual rotation backgrounds with different speed were explored. 14 university students participated in the ex-periment. EEG signals were recorded when they were performing three different cognitive tasks with increasing mental load, that is no response task, selective switch responses task and selec-tive mental arithmetic task. Rotary chair was used to create constant low-speed10/srotation. Four kinds of background were used in this experiment, they were normal black background and constant 30o /s, 45o /s or 60o /s rotating simulated star background. The P1 and N1 compo-nents of brain event-related potentials (ERP) were analyzed to detect the early visual cognitive processing changes. It was found that compared with task performed under other backgrounds, the posterior P1 and N1 latencies were shortened under 45o /s rotating background in all kinds of cognitive tasks. In the no response task, compared with task performed under black back-ground, the posterior N1 latencies were delayed under 30o /s rotating background. In the selec-tive switch responses task and selective mental arithmetic task, compared with task performed under other background, the P1 latencies were lengthened under 60o /s rotating background, but the average amplitudes of the posterior P1 and N1 were increased. It was suggested that under constant 10/s rotation, the facilitated effect of rotating visual background were changed to an inhibited one in 30o /s rotating background. Under vestibular new environment, not all of the rotating backgrounds accelerated the early process of visual cognition. There is a synergic effect between the effects of constant low-speed rotation and rotating speed of the background. Under certain conditions, they both served to facilitate the visual cognitive processing, and it had been started at the stage when extrastriate cortex perceiving the visual signal. Under the condition of constant low-speed rotation in higher cognitive load tasks, the rapid rotation of the background enhanced the magnitude of the signal transmission in the visual path, making signal to noise ratio increased and a higher signal to noise ratio is clearly in favor of target perception and recognition. This gave rise to the hypothesis that higher cognitive load tasks with higher top-down control had more power in counteracting the inhibition effect of higher velocity rotation background. Acknowledgements: This project was supported by National Natural Science Foundation of China (No. 30670715) and National High Technology Research and Development Program of China (No.2007AA04Z254).

  1. Effects of Successive Rotation Regimes on Carbon Stocks in Eucalyptus Plantations in Subtropical China Measured over a Full Rotation.

    PubMed

    Li, Xiaoqiong; Ye, Duo; Liang, Hongwen; Zhu, Hongguang; Qin, Lin; Zhu, Yuling; Wen, Yuanguang

    2015-01-01

    Plantations play an important role in carbon sequestration and the global carbon cycle. However, there is a dilemma in that most plantations are managed on short rotations, and the carbon sequestration capacities of these short-rotation plantations remain understudied. Eucalyptus has been widely planted in the tropics and subtropics due to its rapid growth, high adaptability, and large economic return. Eucalyptus plantations are primarily planted in successive rotations with a short rotation length of 6~8 years. In order to estimate the carbon-stock potential of eucalyptus plantations over successive rotations, we chose a first rotation (FR) and a second rotation (SR) stand and monitored the carbon stock dynamics over a full rotation from 1998 to 2005. Our results showed that carbon stock in eucalyptus trees (TC) did not significantly differ between rotations, while understory vegetation (UC) and soil organic matter (SOC) stored less carbon in the SR (1.01 vs. 2.76 Mg.ha(-1) and 70.68 vs. 81.08 Mg. ha(-1), respectively) and forest floor carbon (FFC) conversely stored more (2.80 vs. 2.34 Mg. ha(-1)). The lower UC and SOC stocks in the SR stand resulted in 1.13 times lower overall ecosystem carbon stock. Mineral soils and overstory trees were the two dominant carbon pools in eucalyptus plantations, accounting for 73.77%~75.06% and 20.50%~22.39%, respectively, of the ecosystem carbon pool. However, the relative contribution (to the ecosystem pool) of FFC stocks increased 1.38 times and that of UC decreased 2.30 times in the SR versus FR stand. These carbon pool changes over successive rotations were attributed to intensive successive rotation regimes of eucalyptus plantations. Our eight year study suggests that for the sustainable development of short-rotation plantations, a sound silvicultural strategy is required to achieve the best combination of high wood yield and carbon stock potential.

  2. Observed changes in radiographic measurements of the first ray after frontal plane rotation of the first metatarsal in a cadaveric foot model.

    PubMed

    Dayton, Paul; Feilmeier, Mindi; Hirschi, Jordan; Kauwe, Merrell; Kauwe, John S K

    2014-01-01

    We observed the changes in the angular measurements commonly used in the evaluation of the first metatarsal and first metatarsophalangeal joint in cadaveric specimens before and after frontal plane rotation of the first metatarsal. Measurements of the first and second intermetatarsal angle (IMA), hallux abductus angle, proximal articular set angle, and tibial sesamoid position (TSP) were taken after varying degrees of varus and valgus rotation of the first metatarsal. Standard dorsoplantar radiographs were taken at 0°, 10°, 20°, and 30° of valgus rotation of the first metatarsal and repeated at 10°, 20°, and 30° varus rotation of the first metatarsal. The data were analyzed using a mixed linear model to compare the change in each angle measurement over the range of valgus and varus rotation. The change in the TSP was significant in both valgus and varus rotations (p = .0004 and p = .028, respectively), an increase in valgus rotation causing an increase in the TSP and an increase in varus rotation causing a decrease in TSP. The change in the IMA was significant compared with valgus rotation (p = .028), showing that as the valgus rotation increased, the IMA also increased. However, compared with the varus rotation, the correlation was not significant (p = .18). The proximal articular set angle and hallux abductus angle measurements, compared with metatarsal rotation, showed positive trends but were not statistically significant. From our results and a review of the published data, we have hypothesized that frontal plane rotation of the first metatarsal is an integral component of hallux abducto valgus pathologic features, specifically in relation to the TSP and IMA. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Trunk-Rotation Flexibility in Collegiate Softball Players With or Without a History of Shoulder or Elbow Injury

    PubMed Central

    Aragon, Veronica J.; Oyama, Sakiko; Oliaro, Scott M.; Padua, Darin A.; Myers, Joseph B.

    2012-01-01

    Context: Throwing is a whole-body motion that requires the transfer of momentum from the lower extremity to the upper extremity via the trunk. No research to date examines the association between a history of shoulder or elbow injury and trunk flexibility in overhead athletes. Objective: To determine if injury history and trunk-rotation flexibility are associated and to compare trunk-rotation flexibility measured using 3 clinical tests: half-kneeling rotation test with the bar in the back, half-kneeling rotation test with the bar in the front, and seated rotation test in softball position players with or without a history of shoulder or elbow injury. Design: Cross-sectional design. Setting: University softball facilities. Patients or Other Participants: Sixty-five female National Collegiate Athletic Association Division I softball position players. Intervention(s): Trunk-rotation flexibility was measured with 3 clinical tests. Recent injury history was obtained using a questionnaire and verified by the certified athletic trainer. Main Outcome Measure(s): Binomial regression models were used to determine if injury history was associated with flexibility categories (high, normal, or limited tertiles) for each of the 6 (3 tests × 2 directions) trunk-rotation flexibility measures. Trunk-rotation flexibility measures from 3 clinical tests were compared between participants with and without a history of shoulder or elbow injury using analysis-of-variance models. Results: When measured using the half-kneeling rotation test with the bar in the back and the seated rotation test, injury history and forward trunk-rotation flexibility were associated. However, no mean group differences were seen in trunk-rotation flexibility between participants with and without a history of shoulder or elbow injury. Conclusions: Limited forward trunk-rotation flexibility may be a risk factor for shoulder or elbow injuries. However, further study is needed to confirm the study finding. PMID:23068587

  4. MOJAVE: Monitoring of Jets in Active Galactic Nuclei with VLBA Experiments. VIII. Faraday Rotation in Parsec-scale AGN Jets

    NASA Astrophysics Data System (ADS)

    Hovatta, Talvikki; Lister, Matthew L.; Aller, Margo F.; Aller, Hugh D.; Homan, Daniel C.; Kovalev, Yuri Y.; Pushkarev, Alexander B.; Savolainen, Tuomas

    2012-10-01

    We report observations of Faraday rotation measures for a sample of 191 extragalactic radio jets observed within the MOJAVE program. Multifrequency Very Long Baseline Array observations were carried out over 12 epochs in 2006 at four frequencies between 8 and 15 GHz. We detect parsec-scale Faraday rotation measures in 149 sources and find the quasars to have larger rotation measures on average than BL Lac objects. The median core rotation measures are significantly higher than in the jet components. This is especially true for quasars where we detect a significant negative correlation between the magnitude of the rotation measure and the de-projected distance from the core. We perform detailed simulations of the observational errors of total intensity, polarization, and Faraday rotation, and concentrate on the errors of transverse Faraday rotation measure gradients in unresolved jets. Our simulations show that the finite image restoring beam size has a significant effect on the observed rotation measure gradients, and spurious gradients can occur due to noise in the data if the jet is less than two beams wide in polarization. We detect significant transverse rotation measure gradients in four sources (0923+392, 1226+023, 2230+114, and 2251+158). In 1226+023 the rotation measure is for the first time seen to change sign from positive to negative over the transverse cuts, which supports the presence of a helical magnetic field in the jet. In this source we also detect variations in the jet rotation measure over a timescale of three months, which are difficult to explain with external Faraday screens and suggest internal Faraday rotation. By comparing fractional polarization changes in jet components between the four frequency bands to depolarization models, we find that an external purely random Faraday screen viewed through only a few lines of sight can explain most of our polarization observations, but in some sources, such as 1226+023 and 2251+158, internal Faraday rotation is needed.

  5. Effects of Successive Rotation Regimes on Carbon Stocks in Eucalyptus Plantations in Subtropical China Measured over a Full Rotation

    PubMed Central

    Li, Xiaoqiong; Ye, Duo; Liang, Hongwen; Zhu, Hongguang; Qin, Lin; Zhu, Yuling; Wen, Yuanguang

    2015-01-01

    Plantations play an important role in carbon sequestration and the global carbon cycle. However, there is a dilemma in that most plantations are managed on short rotations, and the carbon sequestration capacities of these short-rotation plantations remain understudied. Eucalyptus has been widely planted in the tropics and subtropics due to its rapid growth, high adaptability, and large economic return. Eucalyptus plantations are primarily planted in successive rotations with a short rotation length of 6~8 years. In order to estimate the carbon-stock potential of eucalyptus plantations over successive rotations, we chose a first rotation (FR) and a second rotation (SR) stand and monitored the carbon stock dynamics over a full rotation from 1998 to 2005. Our results showed that carbon stock in eucalyptus trees (TC) did not significantly differ between rotations, while understory vegetation (UC) and soil organic matter (SOC) stored less carbon in the SR (1.01 vs. 2.76 Mg.ha-1 and 70.68 vs. 81.08 Mg. ha-1, respectively) and forest floor carbon (FFC) conversely stored more (2.80 vs. 2.34 Mg. ha-1). The lower UC and SOC stocks in the SR stand resulted in 1.13 times lower overall ecosystem carbon stock. Mineral soils and overstory trees were the two dominant carbon pools in eucalyptus plantations, accounting for 73.77%~75.06% and 20.50%~22.39%, respectively, of the ecosystem carbon pool. However, the relative contribution (to the ecosystem pool) of FFC stocks increased 1.38 times and that of UC decreased 2.30 times in the SR versus FR stand. These carbon pool changes over successive rotations were attributed to intensive successive rotation regimes of eucalyptus plantations. Our eight year study suggests that for the sustainable development of short-rotation plantations, a sound silvicultural strategy is required to achieve the best combination of high wood yield and carbon stock potential. PMID:26186367

  6. Observations of Near-Field Rotational Motions from Oklahoma Seismicity using Applied Technology Associate Sensors

    NASA Astrophysics Data System (ADS)

    Ringler, A. T.; Anthony, R. E.; Holland, A. A.; Wilson, D. C.

    2017-12-01

    Characterizing rotational motions from moderate-sized earthquakes in the near-field has the potential to improve earthquake engineering and seismic gradiometry by better characterizing the rotational component of the seismic wavefield, but has remained challenging due to the limited development of portable, low-noise rotational sensors. Here, we test Applied Technology Associate (ATA) Proto-Seismic Magnetohydrodynamic (SMHD) three-component rotational rate sensors at Albuquerque Seismological Laboratory (ASL) for self-noise and sensitivity before deploying them at U.S. Geological Survey (USGS) temporary aftershock station OK38 in Waynoka, Oklahoma. The sensors have low self-noise levels below 2 Hz, making them ideal to record local rotations. From April 11, 2017 to June 6, 2017 we recorded the translational and rotational motions of over 155 earthquakes of ML≥2.0 within 2 degrees of the station. Using the recorded events we compare Peak Ground Velocity (PGV) with Peak Ground Rotation Rate (PG). For example, we measured a maximal PG of 0.00211 radians/s and 0.00186 radians/s for the horizontal components of the two rotational sensors during the Mwr=4.2 event on May 13, 2017 which was 0.5 km from that station. Similarly, our PG for the vertical rotational components were 0.00112 radians/s and 0.00085 radians/s. We also measured Peak Ground Rotations (PGω) as a function of seismic moment, as well as mean vertical Power Spectral Density (PSD) with mean horizontal PSD power levels. We compute apparent phase velocity directly from the rotational data, which may have may improve estimates of local site effects. Finally, by comparing various rotational and translational components we look at potential implications for estimating local event source parameters, which may help in identifying phenomena such as repeating earthquakes by using differences in the rotational components correlation.

  7. Evaluating gyrochronology on the zero-age-main-sequence: rotation periods in the southern open cluster Blanco 1 from the Kelt-South survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cargile, P. A.; Pepper, J.; Siverd, R.

    2014-02-10

    We report periods for 33 members of Blanco 1 as measured from Kilodegree Extremely Little Telescope-South light curves, the first reported rotation periods for this benchmark zero-age-main-sequence open cluster. The distribution of these stars spans from late-A or early-F dwarfs to mid-K with periods ranging from less than a day to ∼8 days. The rotation period distribution has a morphology similar to the coeval Pleiades cluster, suggesting the universal nature of stellar rotation distributions. Employing two different gyrochronology methods, we find an age of 146{sub −14}{sup +13} Myr for the cluster. Using the same techniques, we infer an age ofmore » 134{sub −10}{sup +9} Myr for the Pleiades measured from existing literature rotation periods. These rotation-derived ages agree with independently determined cluster ages based on the lithium depletion boundary technique. Additionally, we evaluate different gyrochronology models and quantify levels of agreement between the models and the Blanco 1/Pleiades rotation period distributions, including incorporating the rotation distributions of clusters at ages up to 1.1 Gyr. We find the Skumanich-like spin-down rate sufficiently describes the rotation evolution of stars hotter than the Sun; however, we find cooler stars rotating faster than predicted by a Skumanich law, suggesting a mass dependence in the efficiency of stellar angular momentum loss rate. Finally, we compare the Blanco 1 and Pleiades rotation period distributions to available nonlinear angular momentum evolution models. We find they require a significant mass dependence on the initial rotation rate of solar-type stars to reproduce the observed range of rotation periods at a given stellar mass and are furthermore unable to predict the observed over-density of stars along the upper envelope of the clusters' rotation distributions.« less

  8. MO-F-CAMPUS-T-05: Correct Or Not to Correct for Rotational Patient Set-Up Errors in Stereotactic Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briscoe, M; Ploquin, N; Voroney, JP

    2015-06-15

    Purpose: To quantify the effect of patient rotation in stereotactic radiation therapy and establish a threshold where rotational patient set-up errors have a significant impact on target coverage. Methods: To simulate rotational patient set-up errors, a Matlab code was created to rotate the patient dose distribution around the treatment isocentre, located centrally in the lesion, while keeping the structure contours in the original locations on the CT and MRI. Rotations of 1°, 3°, and 5° for each of the pitch, roll, and yaw, as well as simultaneous rotations of 1°, 3°, and 5° around all three axes were applied tomore » two types of brain lesions: brain metastasis and acoustic neuroma. In order to analyze multiple tumour shapes, these plans included small spherical (metastasis), elliptical (acoustic neuroma), and large irregular (metastasis) tumour structures. Dose-volume histograms and planning target volumes were compared between the planned patient positions and those with simulated rotational set-up errors. The RTOG conformity index for patient rotation was also investigated. Results: Examining the tumour volumes that received 80% of the prescription dose in the planned and rotated patient positions showed decreases in prescription dose coverage of up to 2.3%. Conformity indices for treatments with simulated rotational errors showed decreases of up to 3% compared to the original plan. For irregular lesions, degradation of 1% of the target coverage can be seen for rotations as low as 3°. Conclusions: This data shows that for elliptical or spherical targets, rotational patient set-up errors less than 3° around any or all axes do not have a significant impact on the dose delivered to the target volume or the conformity index of the plan. However the same rotational errors would have an impact on plans for irregular tumours.« less

  9. A CBCT study of the gravity-induced movement in rotating rabbits

    NASA Astrophysics Data System (ADS)

    Barber, Jeffrey; Shieh, Chun-Chien; Counter, William; Sykes, Jonathan; Bennett, Peter; Ahern, Verity; Corde, Stéphanie; Heng, Soo-Min; White, Paul; Jackson, Michael; Liu, Paul; Keall, Paul J.; Feain, Ilana

    2018-05-01

    Fixed-beam radiotherapy systems with subjects rotating about a longitudinal (horizontal) axis are subject to gravity-induced motion. Limited reports on the degree of this motion, and any deformation, has been reported previously. The purpose of this study is to quantify the degree of anatomical motion caused by rotating a subject around a longitudinal axis, using cone-beam CT (CBCT). In the current study, a purpose-made longitudinal rotating was aligned to a Varian TrueBeam kV imaging system. CBCT images of three live rabbits were acquired at fixed rotational offsets of the cradle. Rigid and deformable image registrations back to the original position were used to quantify the motion experienced by the subjects under rotation. In the rotation offset CBCTs, the mean magnitude of rigid translations was 5.7  ±  2.7 mm across all rabbits and all rotations. The translation motion was reproducible between multiple rotations within 2.1 mm, 1.1 mm, and 2.8 mm difference for rabbit 1, 2, and 3, respectively. The magnitude of the mean and absolute maximum deformation vectors were 0.2  ±  0.1 mm and 5.4  ±  2.0 mm respectively, indicating small residual deformations after rigid registration. In the non-rotated rabbit 4DCBCT, respiratory diaphragm motion up to 5 mm was observed, and the variation in respiratory motion as measured from a series of 4DCBCT scans acquired at each rotation position was small. The principle motion of the rotated subjects was rigid translational motion. The deformation of the anatomy under rotation was found to be similar in scale to normal respiratory motion. This indicates imaging and treatment of rotated subjects with fixed-beam systems can use rigid registration as the primary mode of motion estimation. While the scaling of deformation from rabbits to humans is uncertain, these proof-of-principle results indicate promise for fixed-beam treatment systems.

  10. Critical study of the distribution of rotational velocities of Be stars. II: Differential rotation and some hidden effects interfering with the interpretation of the V sin I parameter

    NASA Astrophysics Data System (ADS)

    Zorec, J.; Frémat, Y.; Domiciano de Souza, A.; Royer, F.; Cidale, L.; Hubert, A.-M.; Semaan, T.; Martayan, C.; Cochetti, Y. R.; Arias, M. L.; Aidelman, Y.; Stee, P.

    2017-06-01

    Aims: We assume that stars may undergo surface differential rotation to study its impact on the interpretation of Vsini and on the observed distribution Φ(u) of ratios of true rotational velocities u = V/Vc (Vc is the equatorial critical velocity). We discuss some phenomena affecting the formation of spectral lines and their broadening, which can obliterate the information carried by Vsini concerning the actual stellar rotation. Methods: We studied the line broadening produced by several differential rotational laws, but adopted Maunder's expression Ω(θ) = Ω0(1 + αcos2θ) as an attempt to account for all of these laws with the lowest possible number of free parameters. We studied the effect of the differential rotation parameter α on the measured Vsini parameter and on the distribution Φ(u) of ratios u = V/Vc. Results: We conclude that the inferred Vsini is smaller than implied by the actual equatorial linear rotation velocity Veq if the stars rotate with α < 0, but is larger if the stars have α > 0. For a given | α | the deviations of Vsini are larger when α < 0. If the studied Be stars have on average α < 0, the number of rotators with Veq ≃ 0.9Vc is larger than expected from the observed distribution Φ(u); if these stars have on average α > 0, this number is lower than expected. We discuss seven phenomena that contribute either to narrow or broaden spectral lines, which blur the information on the rotation carried by Vsini and, in particular, to decide whether the Be phenomenon mostly rely on the critical rotation. We show that two-dimensional radiation transfer calculations are needed in rapid rotators to diagnose the stellar rotation more reliably.

  11. Control of π-Electron Rotations in Chiral Aromatic Molecules Using Intense Laser Pulses

    NASA Astrophysics Data System (ADS)

    Kanno, Manabu; Kono, Hirohiko; Fujimura, Yuichi

    Our recent theoretical studies on laser-induced π-electron rotations in chiral aromatic molecules are reviewed. π electrons of a chiral aromatic molecule can be rotated along its aromatic ring by a nonhelical, linearly polarized laser pulse. An ansa aromatic molecule with a six-membered ring, 2,5-dichloro[n](3,6) pyrazinophane, which belongs to a planar-chiral molecule group, and its simplified molecule 2,5-dichloropyrazine are taken as model molecules. Electron wavepacket simulations in the frozen-molecular-vibration approximation show that the initial direction of π-electron rotation depends on the polarization direction of a linearly polarized laser pulse applied. Consecutive unidirectional rotation can be achieved by applying a sequence of linearly polarized pump and dump pulses to prevent reverse rotation. Optimal control simulations of π-electron rotation show that another controlling factor for unidirectional rotation is the relative optical phase between the different frequency components of an incident pulse in addition to photon polarization direction. Effects of nonadiabatic coupling between π-electron rotation and molecular vibrations are also presented, where the constraints of the frozen approximation are removed. The angular momentum gradually decays mainly owing to nonadiabatic coupling, while the vibrational amplitudes greatly depend on their rotation direction. This suggests that the direction of π-electron rotation on an attosecond timescale can be identified by detecting femtosecond molecular vibrations.

  12. Nearshore sandbar rotation at single-barred embayed beaches

    NASA Astrophysics Data System (ADS)

    Blossier, B.; Bryan, K. R.; Daly, C. J.; Winter, C.

    2016-04-01

    The location of a shore-parallel nearshore sandbar derived from 7 years of video imagery data at the single-barred embayed Tairua Beach (NZ) is investigated to assess the contribution of barline rotation to the overall morphodynamics of sandbars in embayed environments and to characterize the process of rotation in relation to external conditions. Rotation induces cross-shore barline variations at the embayment extremities on the order of magnitude of those induced by alongshore uniform cross-shore migration of the bar. Two semiempirical models have been developed to relate the barline cross-shore migration and rotation to external wave forcing conditions. The rotation model is directly derived from the cross-shore migration model. Therefore, its formulation advocates for a primary role of cross-shore processes in the rotation of sandbars at embayed beaches. The orientation evolves toward an equilibrium angle directly related to the alongshore wave energy gradient due to two different mechanisms. Either the bar extremities migrate in opposite directions with no overall cross-shore bar migration (pivotal rotation) or the rotation relates to an overall migration of the barline which is not uniform along the beach (migration-driven rotation). Migration and rotation characteristic response times are similar, ranging from 10 to 30 days for mild and energetic wave conditions and above 200 days during very calm conditions or when the bar is located far offshore.

  13. Hemodynamic Improvement in Cardiac Resynchronization Does Not Require Improvement in Left Ventricular Rotation Mechanics

    PubMed Central

    Ashikaga, Hiroshi; Leclercq, Christophe; Wang, Jiangxia; Kass, David A.; McVeigh, Elliot R.

    2010-01-01

    Background Earlier studies have yielded conflicting evidence on whether or not cardiac resynchronization therapy (CRT) improves left ventricular (LV) rotation mechanics. Methods and Results In dogs with left bundle branch block and pacing-induced heart failure (n=7), we studied the effects of CRT on LV rotation mechanics in vivo by 3-dimensional tagged magnetic resonance imaging with a temporal resolution of 14 ms. CRT significantly improved hemodynamic parameters but did not significantly change the LV rotation or rotation rate. LV torsion, defined as LV rotation of each slice with respect to that of the most basal slice, was not significantly changed by CRT. CRT did not significantly change the LV torsion rate. There was no significant circumferential regional heterogeneity (anterior, lateral, inferior, and septal) in LV rotation mechanics in either left bundle branch block with pacing-induced heart failure or CRT, but there was significant apex-to-base regional heterogeneity. Conclusions CRT acutely improves hemodynamic parameters without improving LV rotation mechanics. There is no significant circumferential regional heterogeneity of LV rotation mechanics in the mechanically dyssynchronous heart. These results suggest that LV rotation mechanics is an index of global LV function, which requires coordination of all regions of the left ventricle, and improvement in LV rotation mechanics appears to be a specific but insensitive index of acute hemodynamic response to CRT. PMID:20478988

  14. Correlation between physical examination and three-dimensional gait analysis in the assessment of rotational abnormalities in children with cerebral palsy.

    PubMed

    Teixeira, Fernando Borge; Ramalho Júnior, Amancio; Morais Filho, Mauro César de; Speciali, Danielli Souza; Kawamura, Catia Miyuki; Lopes, José Augusto Fernandes; Blumetti, Francesco Camara

    2018-01-01

    Objective To evaluate the correlation between physical examination data concerning hip rotation and tibial torsion with transverse plane kinematics in children with cerebral palsy; and to determine which time points and events of the gait cycle present higher correlation with physical examination findings. Methods A total of 195 children with cerebral palsy seen at two gait laboratories from 2008 and 2016 were included in this study. Physical examination measurements included internal hip rotation, external hip rotation, mid-point hip rotation and the transmalleolar axis angle. Six kinematic parameters were selected for each segment to assess hip rotation and shank-based foot rotation. Correlations between physical examination and kinematic measures were analyzed by Spearman correlation coefficients, and a significance level of 5% was considered. Results Comparing physical examination measurements of hip rotation and hip kinematics, we found moderate to strong correlations for all variables (p<0.001). The highest coefficients were seen between the mid-point hip rotation on physical examination and hip rotation kinematics (rho range: 0.48-0.61). Moderate correlations were also found between the transmalleolar axis angle measurement on physical examination and foot rotation kinematics (rho range 0.44-0.56; p<0.001). Conclusion These findings may have clinical implications in the assessment and management of transverse plane gait deviations in children with cerebral palsy.

  15. Assessment of the midflexion rotational laxity in posterior-stabilized total knee arthroplasty.

    PubMed

    Hino, Kazunori; Kutsuna, Tatsuhiko; Oonishi, Yoshio; Watamori, Kunihiko; Kiyomatsu, Hiroshi; Iseki, Yasutake; Watanabe, Seiji; Ishimaru, Yasumitsu; Miura, Hiromasa

    2017-11-01

    To evaluate changes in midflexion rotational laxity before and after posterior-stabilized (PS)-total knee arthroplasty (TKA). Twenty-nine knees that underwent PS-TKA were evaluated. Manual mild passive rotational stress was applied to the knees, and the internal-external rotational angle was measured automatically by a navigation system at 30°, 45°, 60°, and 90° of knee flexion. The post-operative internal rotational laxity was statistically significantly increased compared to the preoperative level at 30°, 45°, 60°, and 90° of flexion. The post-operative external rotational laxity was statistically significantly decreased compared to the preoperative level at 45° and 60° of flexion. The post-operative internal-external rotational laxity was statistically significantly increased compared to the preoperative level only at 30° of flexion. The preoperative and post-operative rotational laxity showed a significant correlation at 30°, 45°, 60°, and 90° of flexion. Internal-external rotational laxity increases at the initial flexion range due to resection of both the anterior or posterior cruciate ligaments and retention of the collateral ligaments in PS-TKA. Preoperative and post-operative rotational laxity indicated a significant correlation at the midflexion range. This study showed that a large preoperative rotational laxity increased the risk of a large post-operative laxity, especially at the initial flexion range in PS-TKA. III.

  16. Frequency Response Function Expansion for Unmeasured Translation and Rotation Dofs for Impedance Modelling Applications

    NASA Astrophysics Data System (ADS)

    Avitabile, P.; O'Callahan, J.

    2003-07-01

    Inclusion of rotational effects is critical for the accuracy of the predicted system characteristics, in almost all system modelling studies. However, experimentally derived information for the description of one or more of the components for the system will generally not have any rotational effects included in the description of the component. The lack of rotational effects has long affected the results from any system model development whether using a modal-based approach or an impedance-based approach. Several new expansion processes are described herein for the development of FRFs needed for impedance-based system models. These techniques expand experimentally derived mode shapes, residual modes from the modal parameter estimation process and FRFs directly to allow for the inclusion of the necessary rotational dof. The FRFs involving translational to rotational dofs are developed as well as the rotational to rotational dof. Examples are provided to show the use of these techniques.

  17. Analysis of the velocity law in the wind of the Be star Lambda Pavonis

    NASA Technical Reports Server (NTRS)

    Chen, Haiqi; Ringuelet, Adela; Sahade, Jorge; Kondo, Yoji

    1989-01-01

    This paper reanalyzes the IUE spectra of Lambda Pavonis secured in 1982 (Sahade et al.). It is found that the profiles of the broad UV lines are either rotationally broadened or nonrotationally broadened and that the rotationally broadened profiles can be sorted out in two groups characterized by rotational velocity values of 170 km/s and of 210 km/s, respectively. From the analysis of the rotational and of the radial velocities it is possible to distinguish two regions in the extended atmosphere of the star, namely, a region which is rotating and a region which is expanding. In the rotating region, the radial velocities are about zero, and the rotational velocity increases from 170 km/s to 250 km/s. In the expanding region, the rotational energy dissipates, the wind is accelerated to a maximum of -155 km/s, and farther out it decelerates.

  18. Sorting photons of different rotational Doppler shifts (RDS) by orbital angular momentum of single-photon with spin-orbit-RDS entanglement.

    PubMed

    Chen, Lixiang; She, Weilong

    2008-09-15

    We demonstrate that single photons from a rotating q-plate exhibit an entanglement in three degrees of freedom of spin, orbital angular momentum, and the rotational Doppler shift (RDS) due to the nonconservation of total spin and orbital angular momenta. We find that the rotational Doppler shift deltaomega = Omega((delta)s + deltal) , where s, l and Omega are quantum numbers of spin, orbital angular momentum, and rotating velocity of the q-plate, respectively. Of interest is that the rotational Doppler shift directly reflects the rotational symmetry of q-plates and can be also expressed as deltaomega = (Omega)n , where n = 2(q-1) denotes the fold number of rotational symmetry. Besides, based on this single-photon spin-orbit-RDS entanglement, we propose an experimental scheme to sort photons of different frequency shifts according to individual orbital angular momentum.

  19. Cerebellar contribution to mental rotation: a cTBS study.

    PubMed

    Picazio, Silvia; Oliveri, Massimiliano; Koch, Giacomo; Caltagirone, Carlo; Petrosini, Laura

    2013-12-01

    A cerebellar role in spatial information processing has been advanced even in the absence of physical manipulation, as occurring in mental rotation. The present study was aimed at investigating the specific involvement of left and right cerebellar hemispheres in two tasks of mental rotation. We used continuous theta burst stimulation to downregulate cerebellar hemisphere excitability in healthy adult subjects performing two mental rotation tasks: an Embodied Mental Rotation (EMR) task, entailing an egocentric strategy, and an Abstract Mental Rotation (AMR) task entailing an allocentric strategy. Following downregulation of left cerebellar hemisphere, reaction times were slower in comparison to sham stimulation in both EMR and AMR tasks. Conversely, identical reaction times were obtained in both tasks following right cerebellar hemisphere and sham stimulations. No effect of cerebellar stimulation side was found on response accuracy. The present findings document a specialization of the left cerebellar hemisphere in mental rotation regardless of the kind of stimulus to be rotated.

  20. Counter-Rotatable Fan Gas Turbine Engine with Axial Flow Positive Displacement Worm Gas Generator

    NASA Technical Reports Server (NTRS)

    Giffin, Rollin George (Inventor); Murrow, Kurt David (Inventor); Fakunle, Oladapo (Inventor)

    2014-01-01

    A counter-rotatable fan turbine engine includes a counter-rotatable fan section, a worm gas generator, and a low pressure turbine to power the counter-rotatable fan section. The low pressure turbine maybe counter-rotatable or have a single direction of rotation in which case it powers the counter-rotatable fan section through a gearbox. The gas generator has inner and outer bodies having offset inner and outer axes extending through first, second, and third sections of a core assembly. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes and extending radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. A combustor section extends through at least a portion of the second section.

  1. Three-dimensional simulations of rapidly rotating core-collapse supernovae: finding a neutrino-powered explosion aided by non-axisymmetric flows

    NASA Astrophysics Data System (ADS)

    Takiwaki, Tomoya; Kotake, Kei; Suwa, Yudai

    2016-09-01

    We report results from a series of three-dimensional (3D) rotational core-collapse simulations for 11.2 and 27 M⊙ stars employing neutrino transport scheme by the isotropic diffusion source approximation. By changing the initial strength of rotation systematically, we find a rotation-assisted explosion for the 27 M⊙ progenitor , which fails in the absence of rotation. The unique feature was not captured in previous two-dimensional (2D) self-consistent rotating models because the growing non-axisymmetric instabilities play a key role. In the rapidly rotating case, strong spiral flows generated by the so-called low T/|W| instability enhance the energy transport from the proto-neutron star (PNS) to the gain region, which makes the shock expansion more energetic. The explosion occurs more strongly in the direction perpendicular to the rotational axis, which is different from previous 2D predictions.

  2. Construction and laboratory test of the fiber optic rotational seismograph FOSREM for rotational seismology area of interest

    NASA Astrophysics Data System (ADS)

    Kurzych, Anna; Jaroszewicz, Leszek R.; Kowalski, Jerzy K.

    2017-05-01

    A relatively young field of study named Rotational Seismology caused a highly interest in an investigation of rotational movements generated by earthquakes, explosions, and ambient vibrations. It includes a wide range of scientific branches. However, this field needs to apply appropriate rotational sensors which should fulfill restrict technical requirements. The presented in this work system FOSREM (Fibre-Optic System for Rotational Events and Phenomena Monitoring) seems to be a promising rotational sensor for such investigation. FOSREM works by measuring the Sagnac effect and generally consists of two basic elements: optical sensor and electronic part. Regarding to its theoretical sensitivity equals 2·10-8 rad/s/Hz1/2, it enables to measure rotation in a wide range of signal amplitude (10-8 rad/s ÷ 10 rad/s) and frequency (DC ÷ 328.12 Hz). Moreover, FOSREM is mobile and remotely controlled via Internet using a special designed software.

  3. Socio-ecological implications of modifying rotation lengths in forestry.

    PubMed

    Roberge, Jean-Michel; Laudon, Hjalmar; Björkman, Christer; Ranius, Thomas; Sandström, Camilla; Felton, Adam; Sténs, Anna; Nordin, Annika; Granström, Anders; Widemo, Fredrik; Bergh, Johan; Sonesson, Johan; Stenlid, Jan; Lundmark, Tomas

    2016-02-01

    The rotation length is a key component of even-aged forest management systems. Using Fennoscandian forestry as a case, we review the socio-ecological implications of modifying rotation lengths relative to current practice by evaluating effects on a range of ecosystem services and on biodiversity conservation. The effects of shortening rotations on provisioning services are expected to be mostly negative to neutral (e.g. production of wood, bilberries, reindeer forage), while those of extending rotations would be more varied. Shortening rotations may help limit damage by some of today's major damaging agents (e.g. root rot, cambium-feeding insects), but may also increase other damage types (e.g. regeneration pests) and impede climate mitigation. Supporting (water, soil nutrients) and cultural (aesthetics, cultural heritage) ecosystem services would generally be affected negatively by shortened rotations and positively by extended rotations, as would most biodiversity indicators. Several effect modifiers, such as changes to thinning regimes, could alter these patterns.

  4. Seismic shear waves as Foucault pendulum

    NASA Astrophysics Data System (ADS)

    Snieder, Roel; Sens-Schönfelder, Christoph; Ruigrok, Elmer; Shiomi, Katsuhiko

    2016-03-01

    Earth's rotation causes splitting of normal modes. Wave fronts and rays are, however, not affected by Earth's rotation, as we show theoretically and with observations made with USArray. We derive that the Coriolis force causes a small transverse component for P waves and a small longitudinal component for S waves. More importantly, Earth's rotation leads to a slow rotation of the transverse polarization of S waves; during the propagation of S waves the particle motion behaves just like a Foucault pendulum. The polarization plane of shear waves counteracts Earth's rotation and rotates clockwise in the Northern Hemisphere. The rotation rate is independent of the wave frequency and is purely geometric, like the Berry phase. Using the polarization of ScS and ScS2 waves, we show that the Foucault-like rotation of the S wave polarization can be observed. This can affect the determination of source mechanisms and the interpretation of observed SKS splitting.

  5. Studies in Non-Equilibrium Statistical Mechanics.

    DTIC Science & Technology

    1982-09-01

    in the formalism, and this is used to simulate the effects of rotational states and collisions. At each stochastic step the energy changes in the...uses of this method. 10. A Scaling Theoretical Analysis of Vibrational Relaxation Experiments: Rotational Effects and Long-Range Collisions 0...in- elude rotational effects through the rotational energy gaps and the rotational distributions. The variables in this theory are a fundamental set

  6. Real-time estimation of prostate tumor rotation and translation with a kV imaging system based on an iterative closest point algorithm.

    PubMed

    Tehrani, Joubin Nasehi; O'Brien, Ricky T; Poulsen, Per Rugaard; Keall, Paul

    2013-12-07

    Previous studies have shown that during cancer radiotherapy a small translation or rotation of the tumor can lead to errors in dose delivery. Current best practice in radiotherapy accounts for tumor translations, but is unable to address rotation due to a lack of a reliable real-time estimate. We have developed a method based on the iterative closest point (ICP) algorithm that can compute rotation from kilovoltage x-ray images acquired during radiation treatment delivery. A total of 11 748 kilovoltage (kV) images acquired from ten patients (one fraction for each patient) were used to evaluate our tumor rotation algorithm. For each kV image, the three dimensional coordinates of three fiducial markers inside the prostate were calculated. The three dimensional coordinates were used as input to the ICP algorithm to calculate the real-time tumor rotation and translation around three axes. The results show that the root mean square error was improved for real-time calculation of tumor displacement from a mean of 0.97 mm with the stand alone translation to a mean of 0.16 mm by adding real-time rotation and translation displacement with the ICP algorithm. The standard deviation (SD) of rotation for the ten patients was 2.3°, 0.89° and 0.72° for rotation around the right-left (RL), anterior-posterior (AP) and superior-inferior (SI) directions respectively. The correlation between all six degrees of freedom showed that the highest correlation belonged to the AP and SI translation with a correlation of 0.67. The second highest correlation in our study was between the rotation around RL and rotation around AP, with a correlation of -0.33. Our real-time algorithm for calculation of rotation also confirms previous studies that have shown the maximum SD belongs to AP translation and rotation around RL. ICP is a reliable and fast algorithm for estimating real-time tumor rotation which could create a pathway to investigational clinical treatment studies requiring real-time measurement and adaptation to tumor rotation.

  7. Real-time estimation of prostate tumor rotation and translation with a kV imaging system based on an iterative closest point algorithm

    NASA Astrophysics Data System (ADS)

    Nasehi Tehrani, Joubin; O'Brien, Ricky T.; Rugaard Poulsen, Per; Keall, Paul

    2013-12-01

    Previous studies have shown that during cancer radiotherapy a small translation or rotation of the tumor can lead to errors in dose delivery. Current best practice in radiotherapy accounts for tumor translations, but is unable to address rotation due to a lack of a reliable real-time estimate. We have developed a method based on the iterative closest point (ICP) algorithm that can compute rotation from kilovoltage x-ray images acquired during radiation treatment delivery. A total of 11 748 kilovoltage (kV) images acquired from ten patients (one fraction for each patient) were used to evaluate our tumor rotation algorithm. For each kV image, the three dimensional coordinates of three fiducial markers inside the prostate were calculated. The three dimensional coordinates were used as input to the ICP algorithm to calculate the real-time tumor rotation and translation around three axes. The results show that the root mean square error was improved for real-time calculation of tumor displacement from a mean of 0.97 mm with the stand alone translation to a mean of 0.16 mm by adding real-time rotation and translation displacement with the ICP algorithm. The standard deviation (SD) of rotation for the ten patients was 2.3°, 0.89° and 0.72° for rotation around the right-left (RL), anterior-posterior (AP) and superior-inferior (SI) directions respectively. The correlation between all six degrees of freedom showed that the highest correlation belonged to the AP and SI translation with a correlation of 0.67. The second highest correlation in our study was between the rotation around RL and rotation around AP, with a correlation of -0.33. Our real-time algorithm for calculation of rotation also confirms previous studies that have shown the maximum SD belongs to AP translation and rotation around RL. ICP is a reliable and fast algorithm for estimating real-time tumor rotation which could create a pathway to investigational clinical treatment studies requiring real-time measurement and adaptation to tumor rotation.

  8. Jet Engine Bird Ingestion Simulations: Comparison of Rotating to Non-Rotating Fan Blades

    NASA Technical Reports Server (NTRS)

    Howard, Samuel A.; Hammer, Jeremiah; Carney, Kelly S.; Pereira, J. Michael

    2013-01-01

    Bird strike events in commercial airliners are a fairly common occurrence. According to data collected by the US Department of Agriculture, over 80,000 bird strikes were reported in the period 1990-2007 in the US alone [1]. As a result, bird ingestion is an important factor in aero engine design and FAA certification. When it comes to bird impacts on engine fan blades, the FAA requires full-scale bird ingestion tests on an engine running at full speed to pass certification requirements. These rotating tests are complex and very expensive. To reduce development costs associated with new materials for fan blades, it is desirable to develop more cost effective testing procedures than full-scale rotating engine tests for material evaluation. An impact test on a non-rotating single blade that captures most of the salient physics of the rotating test would go a long way towards enabling large numbers of evaluative material screening tests. NASA Glenn Research Center has been working to identify a static blade test procedure that would be effective at reproducing similar results as seen in rotating tests. The current effort compares analytical simulations of a bird strike on various nonrotating blades to a bird strike simulation on a rotating blade as a baseline case. Several different concepts for simulating the rotating loads on a non-rotating blade were analyzed with little success in duplicating the deformation results seen in the rotating case. The rotating blade behaves as if it were stiffer than the non-rotating blade resulting in less plastic deformation from a given bird impact. The key factor limiting the success of the non-rotating blade simulations is thought to be the effect of gyroscopics. Prior to this effort, it was anticipated the difficulty would be in matching the pre-stress in the blade due to centrifugal forces Additional work is needed to verify this assertion, and to determine if a static test procedure can simulate the gyroscopic effects in a suitable manner. This paper describes the various non-rotating concepts analyzed, and demonstrates the effect believed to be gyroscopic in nature on the results.

  9. Jet Engine Bird Ingestion Simulations: Comparison of Rotating to Non-Rotating Fan Blades

    NASA Technical Reports Server (NTRS)

    Howard, Samuel A.; Hammer, Jeremiah T.; Carney, Kelly S.; Pereira, J. Michael

    2013-01-01

    Bird strike events in commercial airliners are a fairly common occurrence. According to data collected by the US Department of Agriculture, over 80,000 bird strikes were reported in the period 1990 to 2007 in the US alone (Ref. 1). As a result, bird ingestion is an important factor in aero engine design and FAA certification. When it comes to bird impacts on engine fan blades, the FAA requires full-scale bird ingestion tests on an engine running at full speed to pass certification requirements. These rotating tests are complex and very expensive. To reduce development costs associated with new materials for fan blades, it is desirable to develop more cost effective testing procedures than full-scale rotating engine tests for material evaluation. An impact test on a nonrotating single blade that captures most of the salient physics of the rotating test would go a long way towards enabling large numbers of evaluative material screening tests. NASA Glenn Research Center has been working to identify a static blade test procedure that would be effective at reproducing similar results as seen in rotating tests. The current effort compares analytical simulations of a bird strike on various non-rotating blades to a bird strike simulation on a rotating blade as a baseline case. Several different concepts for simulating the rotating loads on a non-rotating blade were analyzed with little success in duplicating the deformation results seen in the rotating case. The rotating blade behaves as if it were stiffer than the non-rotating blade resulting in less plastic deformation from a given bird impact. The key factor limiting the success of the non-rotating blade simulations is thought to be the effect of gyroscopics. Prior to this effort, it was anticipated the difficulty would be in matching the prestress in the blade due to centrifugal forces Additional work is needed to verify this assertion, and to determine if a static test procedure can simulate the gyroscopic effects in a suitable manner. This paper describes the various non-rotating concepts analyzed, and demonstrates the effect believed to be gyroscopic in nature on the results

  10. Muscle activity response to external moment during single-leg drop landing in young basketball players: the importance of biceps femoris in reducing internal rotation of knee during landing.

    PubMed

    Fujii, Meguru; Sato, Haruhiko; Takahira, Naonobu

    2012-01-01

    Internal tibial rotation with the knee close to full extension combined with valgus collapse during drop landing generally results in non-contact anterior cruciate ligament (ACL) injury. The purpose of this study was to investigate the relationship between internal rotation of the knee and muscle activity from internal and external rotator muscles, and between the internal rotation of knee and externally applied loads on the knee during landing in collegiate basketball players. Our hypothesis was that the activity of biceps femoris muscle would be an important factor reducing internal knee rotation during landing. The subjects were 10 collegiate basketball students: 5 females and 5 males. The subjects performed a single-leg drop landing from a 25-cm height. Femoral and tibial kinematics were measured using a 3D optoelectronic tracking system during the drop landings, and then the knee angular motions were determined. Ground reaction forces and muscle activation patterns (lateral hamstring and medial hamstring) were simultaneously measured and computed. Results indicated that lower peak internal tibial rotation angle at the time of landing was associated with greater lateral hamstring activity (r = -0.623, p < 0.001). When gender was considered, the statistically significant correlation remained only in females. There was no association between the peak internal tibial rotation angle and the knee internal rotation moment. Control of muscle activity in the lateral to medial hamstring would be an important factor in generating sufficient force to inhibit excessive internal rotation during landing. Strengthening the biceps femoris might mitigate the higher incidence of non-contact ACL injury in female athletes. Key pointsLower activity of the external rotator muscle of the knee, which inhibits internal rotation of the knee, may be the reason why females tend to show a large internal rotation of the knee during drop landing.Externally applied internal rotation moment of the knee during landing would not be expected to explain why female athletes tend to show excessive internal knee rotation.Biceps femoris strength training might help decrease the incidence of non-contact ACL injury in female athletes.

  11. Hydrodynamic interactions between a self-rotation rotator and passive particles

    NASA Astrophysics Data System (ADS)

    Ouyang, Zhenyu; Lin, Jian-Zhong; Ku, Xiaoke

    2017-10-01

    In this paper, we numerically investigate the hydrodynamic interaction between a self-rotation rotator and passive particles in a two-dimensional confined cavity at two typical Reynolds numbers according to the different flow features. Both the fluid-particle interaction and particle-particle interaction through fluid media are taken into consideration. The results show that from the case of a rotator and one passive particle to the case of a rotator and two passive particles, the system becomes much more complex because the relative displacement between the rotator and the passive particles and the velocity of passive particles are strongly dependent on the Reynolds number and the initial position of passive particles. For the system of two particles, the passive particle gradually departs from the rotator although its relative displacement to the rotator exhibits a periodic oscillation at the lower Reynolds number. Furthermore, the relative distance between the two particles and the rotator's rotational frequency are responsible for the oscillation amplitude and frequency of the passive particle's velocity. For the system of three particles, the passive particle's velocities exhibit a superposition of a large amplitude oscillation and a small amplitude oscillation at the lower Reynolds number, and the large amplitude oscillation will disappear at the higher Reynolds number. The change of the included angle of the two passive particles is dependent on the initial positions of the passive particles at the lower Reynolds number, whereas the included angle of the two passive particles finally approaches a fixed value at the higher Reynolds number. It is interesting that the two passive particles periodically approach and depart from each other when the included angle is not equal to π, while all the three particles (including the rotator) keep the positions in a straight line when the included angle is equal to π because the interference between two passive particles disappears. In addition, the passive particle rotates not only around the rotator but also around its own axis, and the rotation speed of the former is far greater than that of the latter.

  12. Magnetic island and plasma rotation under external resonant magnetic perturbation in the T-10 tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eliseev, L. G.; Ivanov, N. V., E-mail: ivanov-nv@nrcki.ru; Kakurin, A. M.

    2015-05-15

    Experimental comparison of the m = 2, n = 1 mode and plasma rotation velocities at q = 2 magnetic surface in a wide range of the mode amplitudes is presented. Phase velocity of the mode rotation is measured with a set of poloidal magnetic field sensors located at the inner side of the vacuum vessel wall. Plasma rotation velocity at the q = 2 magnetic surface in the direction of the mode phase velocity is measured with the heavy ion beam probe diagnostics. In the presence of a static Resonant Magnetic Perturbation (RMP), the rotation is irregular that appears as cyclical variations of the mode and plasmamore » instantaneous velocities. The period of these variations is equal to the period of the mode oscillations. In the case of high mode amplitude, the rotation irregularity of the mode is consistent with the rotation irregularity of the resonant plasma layer. On the contrary, the observed rise of the mode rotation irregularity in the case of low mode amplitude occurs without an increase of the rotation irregularity of the resonant plasma layer. The experimental results are simulated and analyzed with the TEAR code based on the two-fluid MHD approximation. Calculated irregularities of the mode and plasma rotation depend on the mode amplitude similar to the experimental data. For large islands, the rotation irregularity is attributed to oscillations of the electromagnetic torque applied to the resonant plasma layer. For small islands, the deviation of the mode rotation velocity from the plasma velocity occurs due to the effect of finite plasma resistivity.« less

  13. Assessment of the rotation motion at the papillary muscle short-axis plane with normal subjects by two-dimensional speckle tracking imaging: a basic clinical study.

    PubMed

    Ni, Xian-Da; Huang, Jun; Hu, Yuan-Ping; Xu, Rui; Yang, Wei-Yu; Zhou, Li-Ming

    2013-01-01

    The aim of this study was to observe the rotation patterns at the papillary muscle plane in the Left Ventricle(LV) with normal subjects using two-dimensional speckle tracking imaging(2D-STI). We acquired standard of the basal, the papillary muscle and the apical short-axis images of the LV in 64 subjects to estimate the LV rotation motion by 2D-STI. The rotational degrees at the papillary muscle short-axis plane were measured at 15 different time points in the analysis of two heart cycles. There were counterclockwise rotation, clockwise rotation, and counterclockwise to clockwise rotation at the papillary muscle plane in the LV with normal subjects, respectively. The ROC analysis of the rotational degrees was performed at the papillary muscle short-axis plane at the peak LV torsion for predicting whether the turnaround point of twist to untwist motion pattern was located at the papillary muscle level. Sensitivity and specificity were 97% and 67%, respectively, with a cut-off value of 0.34°, and an area under the ROC curve of 0.8. At the peak LV torsion, there was no correlation between the rotational degrees at the papillary muscle short-axis plane and the LVEF in the normal subjects(r = 0.000, p = 0.998). In the study, we conclude that there were three rotation patterns at the papillary muscle short-axis levels, and the transition from basal clockwise rotation to apical counterclockwise rotation is located at the papillary muscle level.

  14. Asteroseismology of Red-Giant Stars: Mixed Modes, Differential Rotation, and Eccentric Binaries

    NASA Astrophysics Data System (ADS)

    Beck, Paul G.

    2013-12-01

    Astronomers are aware of rotation in stars since Galileo Galilei attributed the movement of sunspots to rotation of the Sun in 1613. In contrast to the Sun, whose surface can be resolved by small telescopes or even the (protected) eye, we detect stars as point sources with no spatial information. Numerous techniques have been developed to derive information about stellar rotation. Unfortunately, most observational data allow only for the surface rotational rate to be inferred. The internal rotational profile, which has a great effect on the stellar structure and evolution, remains hidden below the top layers of the star - the essential is hidden to the eyes. Asteroseismology allows us to "sense" indirectly deep below the stellar surface. Oscillations that propagate through the star provide information about the deep stellar interiors while they also distort the stellar surface in characteristic patterns leading to detectable brightness or velocity variations. Also, certain oscillation modes are sensitive to internal rotation and carry information on how the star is spinning deep inside. Thanks to the unprecedented quality of NASA's space telescope Kepler, numerous detailed observations of stars in various evolutionary stages are available. Such high quality data allow that for many stars, rotation can not only be constrained from surface rotation, but also investigated through seismic studies. The work presented in this thesis focuses on the oscillations and internal rotational gradient of evolved single and binary stars. It is shown that the seismic analysis can reach the cores of oscillating red-giant stars and that these cores are rapidly rotating, while nested in a slowly rotating convective envelope.

  15. The value of a core clinical rotation in urology for medical students.

    PubMed

    Patel, Premal; Nayak, Jasmir G; McGregor, Thomas B

    2015-01-01

    In 2013, our institution underwent a change to the undergraduate medical curriculum whereby a clinical urology rotation became mandatory. In this paper, we evaluated the perceived utility and value of this change in the core curriculum. Third year medical students, required to complete a mandatory 1-week clinical urology rotation, were asked to complete a survey before and after their rotation. Fourth year medical students, not required to complete this rotation, were also asked to complete a questionnaire. Chi-squared and Fisher's exact test were used for data analysis. In total, 108 third year students rotated through urology during the study period. Of these, 66 (61%) completed the pre-rotation survey and 54 (50%) completed the post-rotation survey. In total, there were 110 fourth year students. Of these, 44 (40%) completed the questionnaire. After completing their mandatory rotations, students felt more comfortable managing and investigating common urological problems, such as hematuria and renal colic. Students felt they had a better understanding of how to insert a Foley catheter and felt comfortable independently inserting a Foley catheter. Importantly, students felt they knew when to consult urology and were also more likely to consider a career in urology. Compared to fourth year students, third year students felt urology was an important component to a family medicine practice and felt they had a better understanding of when to consult urology. The introduction of a mandatory urology rotation for undergraduate medical students leads to a perceived improvement in fundamental urological knowledge and skill set of rotating students. This mandatory rotation provides a valuable experience that validates its inclusion.

  16. Indications for reverse total shoulder arthroplasty in rotator cuff disease.

    PubMed

    Drake, Gregory N; O'Connor, Daniel P; Edwards, T Bradley

    2010-06-01

    Reverse total shoulder arthroplasty (RTSA) was introduced to treat rotator cuff tear arthropathy but is now used to treat a variety of problems. Although its use has expanded substantially since the FDA's approval in 2004, the appropriateness in patients with rotator cuff disease is unclear. We review the use of RTSA in patients with rotator cuff disease to (1) describe classification of rotator cuff tear reparability and the concept of a balanced shoulder; (2) explore the theory behind RTSA design relative to rotator cuff arthropathy; (3) discuss the indications and contraindications for RTSA; and (4) review published outcomes of RTSA for rotator cuff arthropathy. We performed a selective review of the literature on the use of RTSA in the treatment of rotator cuff disease. Modern RTSA designs restore deltoid tension and a functional fulcrum to the rotator cuff deficient shoulder, which allows recovery of active shoulder elevation and effectively restores function in short- and medium-term followup studies. In short-term followup the RTSA relieves symptoms and restores function for patients with cuff tear arthropathy and irreparable rotator cuff tears with pseudoparalysis (preserved deltoid contraction but loss of active elevation). Severely impaired deltoid function, an isolated supraspinatus tear, and the presence of full active shoulder elevation with a massive rotator cuff tear and arthritis are contraindications to RTSA. For properly selected patients who have symptomatic and disabling rotator cuff deficiency, RTSA can result in life-changing improvements in pain, motion, function, and patient satisfaction. Level V therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

  17. Generalisation, decision making, and embodiment effects in mental rotation: A neurorobotic architecture tested with a humanoid robot.

    PubMed

    Seepanomwan, Kristsana; Caligiore, Daniele; Cangelosi, Angelo; Baldassarre, Gianluca

    2015-12-01

    Mental rotation, a classic experimental paradigm of cognitive psychology, tests the capacity of humans to mentally rotate a seen object to decide if it matches a target object. In recent years, mental rotation has been investigated with brain imaging techniques to identify the brain areas involved. Mental rotation has also been investigated through the development of neural-network models, used to identify the specific mechanisms that underlie its process, and with neurorobotics models to investigate its embodied nature. Current models, however, have limited capacities to relate to neuro-scientific evidence, to generalise mental rotation to new objects, to suitably represent decision making mechanisms, and to allow the study of the effects of overt gestures on mental rotation. The work presented in this study overcomes these limitations by proposing a novel neurorobotic model that has a macro-architecture constrained by knowledge held on brain, encompasses a rather general mental rotation mechanism, and incorporates a biologically plausible decision making mechanism. The model was tested using the humanoid robot iCub in tasks requiring the robot to mentally rotate 2D geometrical images appearing on a computer screen. The results show that the robot gained an enhanced capacity to generalise mental rotation to new objects and to express the possible effects of overt movements of the wrist on mental rotation. The model also represents a further step in the identification of the embodied neural mechanisms that may underlie mental rotation in humans and might also give hints to enhance robots' planning capabilities. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. A description of rotations for DEM models of particle systems

    NASA Astrophysics Data System (ADS)

    Campello, Eduardo M. B.

    2015-06-01

    In this work, we show how a vector parameterization of rotations can be adopted to describe the rotational motion of particles within the framework of the discrete element method (DEM). It is based on the use of a special rotation vector, called Rodrigues rotation vector, and accounts for finite rotations in a fully exact manner. The use of fictitious entities such as quaternions or complicated structures such as Euler angles is thereby circumvented. As an additional advantage, stick-slip friction models with inter-particle rolling motion are made possible in a consistent and elegant way. A few examples are provided to illustrate the applicability of the scheme. We believe that simple vector descriptions of rotations are very useful for DEM models of particle systems.

  19. Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror

    NASA Technical Reports Server (NTRS)

    Li, Steven

    2011-01-01

    A laser cavity was designed and implemented by using a wedged polarization rotator and a Porro prism in order to reduce the parts count, and to improve the laser reliability. In this invention, a z-cut quartz polarization rotator is used to compensate the wavelength retardance introduced by the Porro prism. The polarization rotator rotates the polarization of the linear polarized beam with a designed angle that is independent of the orientation of the rotator. This unique property was used to combine the retardance compensation and a Risley prism to a single optical component: a wedged polarization rotator. This greatly simplifies the laser alignment procedure and reduces the number of the laser optical components.

  20. In-line rotating capacitive torque sensor

    DOEpatents

    Kronberg, James W.

    1991-01-01

    A method and apparatus for measuring torques developed along a rotating mechanical assembly comprising a rotating inner portion and a stationary outer portion. The rotating portion has an electrically-conductive flexing section fitted between two coaxial shafts in a configuration which varies radially in accordance with applied torque. The stationary portion comprises a plurality of conductive plates forming a surface concentric with and having a diameter slightly larger than the diameter of the rotating portion. The capacitance between the outer, nonrotating and inner, rotating portion varies with changes in the radial configuration of the rotating portion. Signal output varies approximately linearly with torque for small torques, nonlinearly for larger torques. The sensor is preferably surrounded by a conductive shell to minimize electrical interference from external sources.

  1. Influence of toroidal rotation on resistive tearing modes in tokamaks

    NASA Astrophysics Data System (ADS)

    Wang, S.; Ma, Z. W.

    2015-12-01

    Influence of toroidal equilibrium plasma rotation on m/n = 2/1 resistive tearing modes is studied numerically using a 3D toroidal MHD code (CLT). It is found that the toroidal rotation with or without shear can suppress the tearing instability and the Coriolis effect in the toroidal geometry plays a dominant role on the rotation induced stabilization. For a high viscosity plasma (τR/τV ≫ 1, where τR and τV represent resistive and viscous diffusion time, respectively), the effect of the rotation shear combined with the viscosity appears to be stabilizing. For a low viscosity plasmas (τR/τV ≪ 1), the rotation shear shows a destabilizing effect when the rotation is large.

  2. SU-E-J-170: Dosimetric Consequences of Uncorrected Rotational Setup Errors During Stereotactic Body Radiation Therapy (SBRT) Treatment of Pancreatic Cancers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Maso, L; Forbang, R Teboh; Zhang, Y

    Purpose: To explore the dosimetric consequences of uncorrected rotational setup errors during SBRT for pancreatic cancer patients. Methods: This was a retrospective study utilizing data from ten (n=10) previously treated SBRT pancreas patients. For each original planning CT, we applied rotational transformations to derive additional CT images representative of possible rotational setup errors. This resulted in 6 different sets of rotational combinations, creating a total of 60 CT planning images. The patients’ clinical dosimetric plans were then applied to their corresponding rotated CT images. The 6 rotation sets encompassed a 3, 2 and 1-degree rotation in each rotational direction andmore » a 3-degree in just the pitch, a 3-degree in just the yaw and a 3-degree in just the roll. After the dosimetric plan was applied to the rotated CT images, the resulting plan was then evaluated and compared with the clinical plan for tumor coverage and normal tissue sparing. Results: PTV coverage, defined here by V33 throughout all of the patients’ clinical plans, ranged from 92–98%. After an n degree rotation in each rotational direction that range decreased to 68–87%, 85–92%, and 88– 94% for n=3, 2 and 1 respectively. Normal tissue sparing defined here by the proximal stomach V15 throughout all of the patients’ clinical plans ranged from 0–8.9 cc. After an n degree rotation in each rotational direction that range increased to 0–17 cc, 0–12 cc, and 0–10 cc for n=3, 2, and 1 respectively. Conclusion: For pancreatic SBRT, small rotational setup errors in the pitch, yaw and roll direction on average caused under dosage to PTV and over dosage to proximal normal tissue. The 1-degree rotation was on average the least detrimental to the normal tissue and the coverage of the PTV. The 3-degree yaw created on average the lowest increase in volume coverage to normal tissue. This research was sponsored by the AAPM Education Council through the AAPM Education and Research Fund for the AAPM Summer Undergraduate Fellowship Program.« less

  3. Remote Evaluation of Rotational Velocity Using a Quadrant Photo-Detector and a DSC Algorithm

    PubMed Central

    Zeng, Xiangkai; Zhu, Zhixiong; Chen, Yang

    2016-01-01

    This paper presents an approach to remotely evaluate the rotational velocity of a measured object by using a quadrant photo-detector and a differential subtraction correlation (DSC) algorithm. The rotational velocity of a rotating object is determined by two temporal-delay numbers at the minima of two DSCs that are derived from the four output signals of the quadrant photo-detector, and the sign of the calculated rotational velocity directly represents the rotational direction. The DSC algorithm does not require any multiplication operations. Experimental calculations were performed to confirm the proposed evaluation method. The calculated rotational velocity, including its amplitude and direction, showed good agreement with the given one, which had an amplitude error of ~0.3%, and had over 1100 times the efficiency of the traditional cross-correlation method in the case of data number N > 4800. The confirmations have shown that the remote evaluation of rotational velocity can be done without any circular division disk, and that it has much fewer error sources, making it simple, accurate and effective for remotely evaluating rotational velocity. PMID:27120607

  4. Simultaneous measurement of bacterial flagellar rotation rate and swimming speed.

    PubMed Central

    Magariyama, Y; Sugiyama, S; Muramoto, K; Kawagishi, I; Imae, Y; Kudo, S

    1995-01-01

    Swimming speeds and flagellar rotation rates of individual free-swimming Vibrio alginolyticus cells were measured simultaneously by laser dark-field microscopy at 25, 30, and 35 degrees C. A roughly linear relation between swimming speed and flagellar rotation rate was observed. The ratio of swimming speed to flagellar rotation rate was 0.113 microns, which indicated that a cell progressed by 7% of pitch of flagellar helix during one flagellar rotation. At each temperature, however, swimming speed had a tendency to saturate at high flagellar rotation rate. That is, the cell with a faster-rotating flagellum did not always swim faster. To analyze the bacterial motion, we proposed a model in which the torque characteristics of the flagellar motor were considered. The model could be analytically solved, and it qualitatively explained the experimental results. The discrepancy between the experimental and the calculated ratios of swimming speed to flagellar rotation rate was about 20%. The apparent saturation in swimming speed was considered to be caused by shorter flagella that rotated faster but produced less propelling force. Images FIGURE 1 FIGURE 4 PMID:8580359

  5. Cargos Rotate at Microtubule Intersections during Intracellular Trafficking.

    PubMed

    Gao, Yuan; Anthony, Stephen M; Yu, Yanqi; Yi, Yi; Yu, Yan

    2018-06-19

    Intracellular cargos are transported by molecular motors along actin and microtubules, but how their dynamics depends on the complex structure of the cytoskeletal network remains unclear. In this study, we investigated this longstanding question by measuring simultaneously the rotational and translational dynamics of cargos at microtubule intersections in living cells. We engineered two-faced particles that are fluorescent on one hemisphere and opaque on the other and used their optical anisotropy to report the rotation of cargos. We show that cargos undergo brief episodes of unidirectional and rapid rotation while pausing at microtubule intersections. Probability and amplitude of the cargo rotation depend on the geometry of the intersecting filaments. The cargo rotation is not random motion due to detachment from microtubules, as revealed by statistical analyses of the translational and rotational dynamics. Instead, it is an active rotation driven by motor proteins. Although cargos are known to pause at microtubule intersections, this study reveals a different dimension of dynamics at this seemingly static state and, more importantly, provides direct evidence showing the correlation between cargo rotation and the geometry of underlying microtubule intersections. Copyright © 2018 Biophysical Society. All rights reserved.

  6. Exploratory Bi-factor Analysis: The Oblique Case.

    PubMed

    Jennrich, Robert I; Bentler, Peter M

    2012-07-01

    Bi-factor analysis is a form of confirmatory factor analysis originally introduced by Holzinger and Swineford (Psychometrika 47:41-54, 1937). The bi-factor model has a general factor, a number of group factors, and an explicit bi-factor structure. Jennrich and Bentler (Psychometrika 76:537-549, 2011) introduced an exploratory form of bi-factor analysis that does not require one to provide an explicit bi-factor structure a priori. They use exploratory factor analysis and a bifactor rotation criterion designed to produce a rotated loading matrix that has an approximate bi-factor structure. Among other things this can be used as an aid in finding an explicit bi-factor structure for use in a confirmatory bi-factor analysis. They considered only orthogonal rotation. The purpose of this paper is to consider oblique rotation and to compare it to orthogonal rotation. Because there are many more oblique rotations of an initial loading matrix than orthogonal rotations, one expects the oblique results to approximate a bi-factor structure better than orthogonal rotations and this is indeed the case. A surprising result arises when oblique bi-factor rotation methods are applied to ideal data.

  7. How imagery changes self-motion perception

    PubMed Central

    Nigmatullina, Y.; Arshad, Q.; Wu, K.; Seemungal, B.M.; Bronstein, A.M.; Soto, D.

    2015-01-01

    Imagery and perception are thought to be tightly linked, however, little is known about the interaction between imagery and the vestibular sense, in particular, self-motion perception. In this study, the observers were seated in the dark on a motorized chair that could rotate either to the right or to the left. Prior to the physical rotation, observers were asked to imagine themselves rotating leftward or rightward. We found that if the direction of imagined rotation was different to the physical rotation of the chair (incongruent trials), the velocity of the chair needed to be higher for observers to experience themselves rotating relative to when the imagined and the physical rotation matched (on congruent trials). Accordingly, the vividness of imagined rotations was reduced on incongruent relative to congruent trials. Notably, we found that similar effects of imagery were found at the earliest stages of vestibular processing, namely, the onset of the vestibular–ocular reflex was modulated by the congruency between physical and imagined rotations. Together, the results demonstrate that mental imagery influences self-motion perception by exerting top-down influences over the earliest vestibular response and subsequent perceptual decision-making. PMID:25637805

  8. Palaeomagnetic evidence for post-thrusting tectonic rotation in the Southeast Pyrenees, Spain

    NASA Astrophysics Data System (ADS)

    Keller, P.; Lowrie, W.; Gehring, A. U.

    1994-12-01

    The structural framework of the Southeast Pyrenees led to two conflicting interpretations—thrust tectonics vs. wrench tectonics—to explain the geometry of this mountain range. In the present study palaeomagnetic data are presented in an attempt to resolve this conflict. The data reveal different magnetisation directions that indicate tectonic rotations about vertical axes. By means of a regionally homogeneous pattern of rotation, three tectonic units could be distinguished in the Southeast Pyrenees. The Internal Unit in the north reveals no rotation since the Permian. The External Unit to the south shows anticlockwise rotation of 25°, younger than the Early Oligocene. The Pedraforca Unit, placed on the External Unit, shows 57° clockwise rotation which can be assigned to the Neogene. The anticlockwise rotation of the External Unit can be explained by differential compression during the last phase of Pyrenean thrusting, whereas the clockwise rotation of the Pedraforca Unit can be interpreted by post-thrusting tectonics. The rotation pattern of the Southeast Pyrenees provides evidence for both Cretaceous to Paleogene N-S compression and Neogene right-lateral wrench tectonics.

  9. Freely-tunable broadband polarization rotator for terahertz waves

    NASA Astrophysics Data System (ADS)

    Peng, Ru-Wen; Fan, Ren-Hao; Zhou, Yu; Jiang, Shang-Chi; Xiong, Xiang; Huang, Xian-Rong; Wang, Mu

    It is known that commercially-available terahertz (THz) emitters usually generate linearly polarized waves only along certain directions, but in practice, a polarization rotator that is capable of rotating the polarization of THz waves to any direction is particularly desirable and it will have various important applications. In this work, we demonstrate a freely tunable polarization rotator for broadband THz waves using a three-rotating-layer metallic grating structure, which can conveniently rotate the polarization of a linearly polarized THz wave to any desired direction with nearly perfect conversion efficiency. The device performance has been experimentally demonstrated by both THz transmission spectra and direct imaging. The polarization rotation originates from multi wave interference in the three-layer grating structure based on the scattering-matrix analysis. We can expect that this active broadband polarization rotator has wide applications in analytical chemistry, biology, communication technology, imaging, etc.. Reference: R. H. Fan, Y. Zhou, X. P. Ren, R. W. Peng, S. C. Jiang, D. H. Xu, X. Xiong, X. R. Huang, and Mu Wang, Advanced Materials 27,1201(2015). Freely-tunable broadband polarization rotator for terahertz waves.

  10. Dynamic train-track interaction at high vehicle speeds—Modelling of wheelset dynamics and wheel rotation

    NASA Astrophysics Data System (ADS)

    Torstensson, P. T.; Nielsen, J. C. O.; Baeza, L.

    2011-10-01

    Vertical dynamic train-track interaction at high vehicle speeds is investigated in a frequency range from about 20 Hz to 2.5 kHz. The inertial effects due to wheel rotation are accounted for in the vehicle model by implementing a structural dynamics model of a rotating wheelset. Calculated wheel-rail contact forces using the flexible, rotating wheelset model are compared with contact forces based on rigid, non-rotating models. For a validation of the train-track interaction model, calculated contact forces are compared with contact forces measured using an instrumented wheelset. When the system is excited at a frequency where two different wheelset mode shapes, due to the wheel rotation, have coinciding resonance frequencies, significant differences are found in the contact forces calculated with the rotating and non-rotating wheelset models. Further, the use of a flexible, rotating wheelset model is recommended for load cases leading to large magnitude contact force components in the high-frequency range (above 1.5 kHz). In particular, the influence of the radial wheel eigenmodes with two or three nodal diameters is significant.

  11. Rotator cuff tendinopathy: a model for the continuum of pathology and related management.

    PubMed

    Lewis, Jeremy S

    2010-10-01

    Pathology of the soft tissues of the shoulder including the musculotendinous rotator cuff and subacromial bursa are extremely common and are a principal cause of pain and suffering. Competing theories have been proposed to explain the pathoaetiology of rotator cuff pathology at specific stages and presentations of the condition. This review proposes a model to describe the continuum of the rotator cuff pathology from asymptomatic tendon through full thickness rotator cuff tears. The pathoaetiology of rotator cuff failure is multifactorial and results from a combination of intrinsic, extrinsic and environmental factors. Recently a new and generic model detailing the continuum of tendon pathology has been proposed. This model is relevant for the rotator cuff and provides a framework to stage the continuity of rotator cuff pathology. Furthermore, it provides a structure to identify the substantial deficiencies in our knowledge base and areas where research would improve our understanding of the pathological and repair process, together with assessment and management. The strength of this model adapted for the rotator cuff tendons and subacromial bursa will be tested in its ability to incorporate and adapt to emerging research.

  12. Response to 'Comment on 'Three-dimensional numerical investigation of electron transport with rotating spoke in a cylindrical anode layer Hall plasma accelerator''[Phys. Plasmas 20, 014701 (2013)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tang, D. L.; Qiu, X. M.; Geng, S. F.

    The numerical simulation described in our paper [D. L. Tang et al., Phys. Plasmas 19, 073519 (2012)] shows a rotating dense plasma structure, which is the critical characteristic of the rotating spoke. The simulated rotating spoke has a frequency of 12.5 MHz with a rotational speed of {approx}1.0 Multiplication-Sign 10{sup 6} m/s on the surface of the anode. Accompanied by the almost uniform azimuthal ion distribution, the non-axisymmetric electron distribution introduces two azimuthal electric fields with opposite directions. The azimuthal electric fields have the same rotational frequency and speed together with the rotating spoke. The azimuthal electric fields excite themore » axial electron drift upstream and downstream due to the additional E{sub {theta}} x B field and then the axial shear flow is generated. The axial local charge separation induced by the axial shear electron flow may be compensated by the azimuthal electron transport, finally resulting in the azimuthal electric field rotation and electron transport with the rotating spoke.« less

  13. Descriptive profile of hip rotation range of motion in elite tennis players and professional baseball pitchers.

    PubMed

    Ellenbecker, Todd S; Ellenbecker, Gail A; Roetert, E Paul; Silva, Rogerio Teixeira; Keuter, Greg; Sperling, Fabio

    2007-08-01

    Repetitive loading to the hip joint in athletes has been reported as a factor in the development of degenerative joint disease and intra-articular injury. Little information is available on the bilateral symmetry of hip rotational measures in unilaterally dominant upper extremity athletes. Side-to-side differences in hip joint range of motion may be present because of asymmetrical loading in the lower extremities of elite tennis players and professional baseball pitchers. Cohort (cross-sectional) study (prevalence); Level of evidence, 1. Descriptive measures of hip internal and external rotation active range of motion were taken in the prone position of 64 male and 83 female elite tennis players and 101 male professional baseball pitchers using digital photos and computerized angle calculation software. Bilateral differences in active range of motion between the dominant and nondominant hip were compared using paired t tests and Bonferroni correction for hip internal, external, and total rotation range of motion. A Pearson correlation test was used to test the relationship between years of competition and hip rotation active range of motion. No significant bilateral difference (P > .005) was measured for mean hip internal or external rotation for the elite tennis players or the professional baseball pitchers. An analysis of the number of subjects in each group with a bilateral difference in hip rotation greater than 10 degrees identified 17% of the professional baseball pitchers with internal rotation differences and 42% with external rotation differences. Differences in the elite male tennis players occurred in only 15% of the players for internal rotation and 9% in external rotation. Female subjects had differences in 8% and 12% of the players for internal and external rotation, respectively. Statistical differences were found between the mean total arc of hip range of internal and external rotation in the elite tennis players with the dominant side being greater by a clinically insignificant mean value of 2.5 degrees. Significantly less (P < .005) dominant hip internal rotation and less dominant and nondominant hip total rotation range of motion were found in the professional baseball pitchers compared with the elite male tennis players. This study established typical range of motion patterns and identified bilaterally symmetric hip active range of motion rotation values in elite tennis players and professional baseball pitchers. Asymmetric hip joint rotational active range of motion encountered during clinical examination and screening may indicate abnormalities and would indicate the application of flexibility training, rehabilitation, and further evaluation.

  14. Rotating Connection for Electrical Cables

    NASA Technical Reports Server (NTRS)

    Manges, D. R.

    1986-01-01

    Cable reel provides electrical connections between fixed structure and rotating one. Reel carries power and signal lines while allowing rotating structure to turn up to 360 degrees with respect to fixed structure. Reel replaces sliprings. Can be used to electrically connect arm of robot with body. Reel releases cable to rotating part as it turns and takes up cable as rotating part comes back to its starting position, without tangling, twisting, or kinking.

  15. Heat Exchanger Design and Testing for a 6-Inch Rotating Detonation Engine

    DTIC Science & Technology

    2013-03-01

    Engine Research Facility HHV Higher heating value LHV Lower heating value PDE Pulsed detonation engine RDE Rotating detonation engine RTD...the combustion community are pulse detonation engines ( PDEs ) and rotating detonation engines (RDEs). 1.1 Differences between Pulsed and Rotating ...steadier than that of a PDE (2, 3). (2) (3) Figure 1. Unrolled rotating detonation wave from high-speed video (4) Another difference that

  16. Separating "Rotators" from "Nonrotators" in the Mental Rotations Test: A Multigroup Latent Class Analysis

    ERIC Educational Resources Information Center

    Geiser, Christian; Lehmann, Wolfgang; Eid, Michael

    2006-01-01

    Items of mental rotation tests can not only be solved by mental rotation but also by other solution strategies. A multigroup latent class analysis of 24 items of the Mental Rotations Test (MRT) was conducted in a sample of 1,695 German pupils and students to find out how many solution strategies can be identified for the items of this test. The…

  17. Rotational Symmetry Breaking in Baby Skyrme Models

    NASA Astrophysics Data System (ADS)

    Karliner, Marek; Hen, Itay

    We discuss one of the most interesting phenomena exhibited by baby skyrmions - breaking of rotational symmetry. The topics we will deal with here include the appearance of rotational symmetry breaking in the static solutions of baby Skyrme models, both in flat as well as in curved spaces, the zero-temperature crystalline structure of baby skyrmions, and finally, the appearance of spontaneous breaking of rotational symmetry in rotating baby skyrmions.

  18. Keeping It in Three Dimensions: Measuring the Development of Mental Rotation in Children with the Rotated Colour Cube Test (RCCT)

    ERIC Educational Resources Information Center

    Lutke, Nikolay; Lange-Kuttner, Christiane

    2015-01-01

    This study introduces the new Rotated Colour Cube Test (RCCT) as a measure of object identification and mental rotation using single 3D colour cube images in a matching-to-sample procedure. One hundred 7- to 11-year-old children were tested with aligned or rotated cube models, distracters and targets. While different orientations of distracters…

  19. Rotating samples in FT-RAMAN spectrometers

    NASA Astrophysics Data System (ADS)

    De Paepe, A. T. G.; Dyke, J. M.; Hendra, P. J.; Langkilde, F. W.

    1997-11-01

    It is customary to rotate samples in Raman spectroscopy to avoid absorption or sample heating. In FT-Raman experiments the rotation is always shown (typically 30-60 rpm) because higher speeds are thought to generate noise in the spectra. In this article we show that more rapid rotation is possible. A tablet containing maleic acid and one made up of sub-millimetre silica particles with metoprolol succinate as active ingredient were rotated at different speeds, up to 6760 rpm. The FT-Raman spectra were recorded and studied. We conclude that it is perfectly acceptable to rotate samples up to 1500 rpm.

  20. SEAL FOR ROTATING SHAFT

    DOEpatents

    Coffman, R.T.

    1957-12-10

    A seal is described for a rotatable shaft that must highly effective when the shaft is not rotating but may be less effective while the shaft is rotating. Weights distributed about a sealing disk secured to the shaft press the sealing disk against a tubular section into which the shiilt extends, and whem the shaft rotates, the centrifugal forces on the weights relieve the pressurc of the sealing disk against the tubular section. This action has the very desirible result of minimizing the wear of the rotating disk due to contact with the tubular section, while affording maximum sealing action when it is needed.

  1. Observation of plasma rotation driven by static nonaxisymmetric magnetic fields in a tokamak.

    PubMed

    Garofalo, A M; Burrell, K H; DeBoo, J C; deGrassie, J S; Jackson, G L; Lanctot, M; Reimerdes, H; Schaffer, M J; Solomon, W M; Strait, E J

    2008-11-07

    We present the first evidence for the existence of a neoclassical toroidal rotation driven in a direction counter to the plasma current by nonaxisymmetric, nonresonant magnetic fields. At high beta and with large injected neutral beam momentum, the nonresonant field torque slows down the plasma toward the neoclassical "offset" rotation rate. With small injected neutral beam momentum, the toroidal rotation is accelerated toward the offset rotation, with resulting improvement in the global energy confinement time. The observed magnitude, direction, and radial profile of the offset rotation are consistent with neoclassical theory predictions.

  2. Homopolar motor with dual rotors

    DOEpatents

    Hsu, J.S.

    1998-12-01

    A homopolar motor has a field rotor mounted on a frame for rotation in a first rotational direction and for producing an electromagnetic field, and an armature rotor mounted for rotation on said frame within said electromagnetic field and in a second rotational direction counter to said first rotational direction of said field rotor. The two rotors are coupled through a 1:1 gearing mechanism, so as to travel at the same speed but in opposite directions. This doubles the output voltage and output power, as compared to a motor in which only the armature is rotated. Several embodiments are disclosed. 7 figs.

  3. Seismic diagnosis from gravity modes strongly affected by rotation

    NASA Astrophysics Data System (ADS)

    Prat, Vincent; Mathis, Stéphane; Lignières, François; Ballot, Jérôme; Culpin, Pierre-Marie

    2017-10-01

    Most of the information we have about the internal rotation of stars comes from modes that are weakly affected by rotation, for example by using rotational splittings. In contrast, we present here a method, based on the asymptotic theory of Prat et al. (2016), which allows us to analyse the signature of rotation where its effect is the most important, that is in low-frequency gravity modes that are strongly affected by rotation. For such modes, we predict two spectral patterns that could be confronted to observed spectra and those computed using fully two-dimensional oscillation codes.

  4. Comparison of range of motion tests with throwing kinematics in elite team handball players.

    PubMed

    van den Tillaar, Roland

    2016-10-01

    The aim of this study was to compare the active and passive range of motion (ROM) of the glenohumeral external rotation with the maximal external rotation and throwing performance during different throws with different wind-up techniques in elite team handball players. Twenty-two elite team handball players participated in the study in which the maximal ball release velocity and maximal external rotation during standing, with run-up and jump throws with two types of wind-ups were measured together with the maximal active and passive glenohumeral ROM of the external rotation, lying supine on a bench. Higher maximal external rotation was found during the throws with the whip-like wind-up in comparison to circular-like wind-up throws together with a lower external rotation during the active ROM test. No correlations were found between the ROM of the external rotation with the maximal ball release velocity and the maximal external rotation measured during the throws. It was concluded that ROM of the external rotation measured on the bench does not give any information about the maximal throwing performance or the external rotation angle during throwing and therefore cannot be used to identify potential fast throwers or injuries in elite team handball players.

  5. A phenomenological treatment of rotating turbulence

    NASA Technical Reports Server (NTRS)

    Zhou, YE

    1995-01-01

    The strong similarity between the magnetohydrodynamic (MHD) turbulence and initially isotropic turbulence subject to rotation is noted. We then apply the MHD phenomenologies of Kraichnan and Matthaeus & Zhou to rotating turbulence. When the turbulence is subject to a strong rotation, the energy spectrum is found to scale as E(k) = C(sub Omega)(Omega(sub epsilon))(sup 1/2)k(sup -2), where Omega is the rotation rate, k is the wavenumber, and epsilon is the dissipation rate. This spectral form is consistent with a recent letter by Zeman. However, here the constant C(sub Omega) is found to be related to the Kolmogorov constant and is estimated in the range 1.22 - 1.87 for the typical values of the latter constant. A 'rule' that relates spectral transfer times to the eddy turnover time and the time scale for decay of the triple correlations is deduced. A hypothesis for the triple correlation decay rate leads to the spectral law which varies between the '-5/3' (without rotation) and '-2' laws (with strong rotation). For intermediate rotation rates, the spectrum varies according to the value of a dimensionless parameter that measures the strength of the rotation wavenumber k(sub Omega) = (Omega(sup 3)/epsiolon)(sup 1/2) relative to the wavenumber k. An eddy viscosity is derived with an explicit dependence on the rotation rate.

  6. Oscillations and instabilities of fast and differentially rotating relativistic stars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krueger, Christian; Gaertig, Erich; Kokkotas, Kostas D.

    2010-04-15

    We study nonaxisymmetric oscillations of rapidly and differentially rotating relativistic stars in the Cowling approximation. Our equilibrium models are sequences of relativistic polytropes, where the differential rotation is described by the relativistic j-constant law. We show that a small degree of differential rotation raises the critical rotation value for which the quadrupolar f-mode becomes prone to the Chandrasekhar-Friedman-Schutz (CFS) instability, while the critical value of T/|W| at the mass-shedding limit is raised even more. For stiffer equations of state these effects are even more pronounced. When increasing differential rotation further to a high degree, the neutral point of the CFSmore » instability first reaches a local maximum and is lowered afterwards. For stars with a rather high compactness we find that for a large degree of differential rotation the absolute value of the critical T/|W| is below the corresponding value for rigid rotation. We conclude that the onset of the CFS instability is eased for a small degree of differential rotation and for a large degree at least in stars with a higher compactness. Moreover, we were able to extract the eigenfrequencies and the eigenfunctions of r-modes for differentially rotating stars and our simulations show a good qualitative agreement with previous Newtonian results.« less

  7. Evaluation of denitrification potential of rotating biological contactors for treatment of municipal wastewater.

    PubMed

    Hanhan, O; Orhon, D; Krauth, Kh; Günder, B

    2005-01-01

    In this study the effect of retention time and rotation speed in the denitrification process in two full-scale rotating biological contactors (RBC) which were operated parallel and fed with municipal wastewater is evaluated. Each rotating biological contactor was covered to prevent oxygen input. The discs were 40% submerged. On the axle of one of the rotating biological contactors lamellas were placed (RBC1). During the experiments the nitrate removal performance of the rotating biological contactor with lamellas was observed to be less than the other (RBC2) since the lamellas caused oxygen diffusion through their movement. The highest nitrate removal observed was 2.06 g/m2.d achieved by a contact time of 28.84 minutes and a recycle flow of 1 l/s. The rotation speed during this set had the constant value of 0.8 min(-1). Nitrate removal efficiency on RBC1 was decreasing with increasing rotation speed. On the rotating biological contactor without lamellas no effect on denitrification could be determined within a speed range from 0.67 to 2.1 min-1. If operated in proper conditions denitrification on RBC is a very suitable alternative for nitrogen removal that can easily fulfil the nutrient limitations in coastal areas due to the rotating biological contactors economical benefits and uncomplicated handling.

  8. Interfacial Octahedral Rotation Mismatch Control of the Symmetry and Properties of SrRuO 3

    DOE PAGES

    Gao, Ran; Dong, Yongqi; Xu, Han; ...

    2016-05-24

    We can use epitaxial strain to tune the properties of complex oxides with perovskite structure. Beyond just lattice mismatch, the use of octahedral rotation mismatch at heterointerfaces could also provide a route to manipulate material properties. We examine the evolution of the lattice (i.e., parameters, symmetry, and octahedral rotations) of SrRuO 3 films grown on substrates engineered to have the same lattice parameters, but 2 different octahedral rotations. SrRuO 3 films grown on SrTiO 3 (001) (no octahedral rotations) and GdScO 3-buffered SrTiO 3 (001) (with octahedral rotations) substrates are found to exhibit monoclinic and tetragonal symmetry, respectively. Electrical transportmore » and magnetic measurements reveal that the tetragonal films exhibit higher resistivity, lower magnetic Curie temperatures, and more isotropic magnetism as compared to those with monoclinic structure. Synchrotron-based half-order Bragg peak analysis reveals that the octahedral rotation pattern in both film variants is the same (albeit with slightly different magnitudes of in-plane rotation angles). Furthermore, the abnormal rotation pattern observed in tetragonal SrRuO 3 indicates a possible decoupling between the internal octahedral rotation and lattice symmetry, which could provide new opportunities to engineer thin-film structure and properties.« less

  9. Titrating decision processes in the mental rotation task.

    PubMed

    Provost, Alexander; Heathcote, Andrew

    2015-10-01

    Shepard and Metzler's (1971) seminal mental-rotation task-which requires participants to decide if 1 object is a rotated version of another or its mirror image-has played a central role in the study of spatial cognition. We provide the first quantitative model of behavior in this task that is comprehensive in the sense of simultaneously providing an account of both error rates and the full distribution of response times. We used Brown and Heathcote's (2008) model of choice processing to separate out the contributions of mental rotation and decision stages. This model-based titration process was applied to data from a paradigm where converging evidence supported performance being based on rotation rather than other strategies. Stimuli were similar to Shepard and Metzler's block figures except a long major axis made rotation angle well defined for mirror stimuli, enabling comprehensive modeling of both mirror and normal responses. Results supported a mental rotation stage based on Larsen's (2014) model, where rotation takes a variable amount of time with a mean and variance that increase linearly with rotation angle. Differences in response threshold differences were largely responsible for mirror responses being slowed, and for errors increasing with rotation angle for some participants. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  10. Ultrasound determination of rotator cuff tear repairability

    PubMed Central

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p < 0.0001) and a specificity of 67% (p < 0.0001). The strongest predictors of rotator cuff repairability were tear size (p < 0.001) and age (p = 0.004). Sonographic assessments of tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  11. The Rotator Cuff Organ: Integrating Developmental Biology, Tissue Engineering, and Surgical Considerations to Treat Chronic Massive Rotator Cuff Tears.

    PubMed

    Rothrauff, Benjamin B; Pauyo, Thierry; Debski, Richard E; Rodosky, Mark W; Tuan, Rocky S; Musahl, Volker

    2017-08-01

    The torn rotator cuff remains a persistent orthopedic challenge, with poor outcomes disproportionately associated with chronic, massive tears. Degenerative changes in the tissues that comprise the rotator cuff organ, including muscle, tendon, and bone, contribute to the poor healing capacity of chronic tears, resulting in poor function and an increased risk for repair failure. Tissue engineering strategies to augment rotator cuff repair have been developed in an effort to improve rotator cuff healing and have focused on three principal aims: (1) immediate mechanical augmentation of the surgical repair, (2) restoration of muscle quality and contractility, and (3) regeneration of native enthesis structure. Work in these areas will be reviewed in sequence, highlighting the relevant pathophysiology, developmental biology, and biomechanics, which must be considered when designing therapeutic applications. While the independent use of these strategies has shown promise, synergistic benefits may emerge from their combined application given the interdependence of the tissues that constitute the rotator cuff organ. Furthermore, controlled mobilization of augmented rotator cuff repairs during postoperative rehabilitation may provide mechanotransductive cues capable of guiding tissue regeneration and restoration of rotator cuff function. Present challenges and future possibilities will be identified, which if realized, may provide solutions to the vexing condition of chronic massive rotator cuff tears.

  12. The interrelationship of the thorax and pelvis under varying task constraints.

    PubMed

    Delphinus, Elias M; Sayers, Mark Gregory Leigh

    2013-01-01

    The purpose of this study was to investigate the interrelationship between the thorax and pelvis during coupled movement patterns. Fifty-seven participants were assessed using an infrared motion analysis system to track trunk movement during maximal pelvis and thorax rotations over four trunk inclinations and two pelvic constraint conditions. A repeated-measures multivariate analysis of variance investigated the effects of forward trunk inclination and pelvic constraint on thorax and pelvic rotation. Forward trunk inclination from neutral to 45° resulted in a 46% (p < 0.001) decrease in axial pelvic rotation and a 15% (p < 0.001) decrease in axial thorax rotation with an unconstrained pelvis. A constrained pelvis resulted in a 15% (p < 0.001) decrease in axial thorax rotation. An externally constrained pelvis allowed the thorax to achieve an average of 18° (SD = 2°) greater rotational range of motion across all angles. This study reinforced the importance of allowing the pelvis to rotate during whole body axial rotation tasks. Results indicated that maximum axial trunk rotation is best achieved in a neutral posture, when the pelvis is allowed to contribute and flexion at the hips should be minimised. For example, if a recumbent task requires rotation of the torso, then the chair seat should be allowed to swivel.

  13. Compensations for increased rotational inertia during human cutting turns.

    PubMed

    Qiao, Mu; Brown, Brian; Jindrich, Devin L

    2014-02-01

    Locomotion in a complex environment is often not steady state, but unsteady locomotion (stability and maneuverability) is not well understood. We investigated the strategies used by humans to perform sidestep cutting turns when running. Previous studies have argued that because humans have small yaw rotational moments of inertia relative to body mass, deceleratory forces in the initial velocity direction that occur during the turning step, or 'braking' forces, could function to prevent body over-rotation during turns. We tested this hypothesis by increasing body rotational inertia and testing whether braking forces during stance decreased. We recorded ground reaction force and body kinematics from seven participants performing 45 deg sidestep cutting turns and straight running at five levels of body rotational inertia, with increases up to fourfold. Contrary to our prediction, braking forces remained consistent at different rotational inertias, facilitated by anticipatory changes to body rotational speed. Increasing inertia revealed that the opposing effects of several turning parameters, including rotation due to symmetrical anterior-posterior forces, result in a system that can compensate for fourfold changes in rotational inertia with less than 50% changes to rotational velocity. These results suggest that in submaximal effort turning, legged systems may be robust to changes in morphological parameters, and that compensations can involve relatively minor adjustments between steps to change initial stance conditions.

  14. Compensations for increased rotational inertia during human cutting turns

    PubMed Central

    Qiao, Mu; Brown, Brian; Jindrich, Devin L.

    2014-01-01

    Locomotion in a complex environment is often not steady state, but unsteady locomotion (stability and maneuverability) is not well understood. We investigated the strategies used by humans to perform sidestep cutting turns when running. Previous studies have argued that because humans have small yaw rotational moments of inertia relative to body mass, deceleratory forces in the initial velocity direction that occur during the turning step, or ‘braking’ forces, could function to prevent body over-rotation during turns. We tested this hypothesis by increasing body rotational inertia and testing whether braking forces during stance decreased. We recorded ground reaction force and body kinematics from seven participants performing 45 deg sidestep cutting turns and straight running at five levels of body rotational inertia, with increases up to fourfold. Contrary to our prediction, braking forces remained consistent at different rotational inertias, facilitated by anticipatory changes to body rotational speed. Increasing inertia revealed that the opposing effects of several turning parameters, including rotation due to symmetrical anterior–posterior forces, result in a system that can compensate for fourfold changes in rotational inertia with less than 50% changes to rotational velocity. These results suggest that in submaximal effort turning, legged systems may be robust to changes in morphological parameters, and that compensations can involve relatively minor adjustments between steps to change initial stance conditions. PMID:24115061

  15. Axisymmetric modes of rotating relativistic stars in the Cowling approximation

    NASA Astrophysics Data System (ADS)

    Font, José A.; Dimmelmeier, Harald; Gupta, Anshu; Stergioulas, Nikolaos

    2001-08-01

    Axisymmetric pulsations of rotating neutron stars can be excited in several scenarios, such as core collapse, crust- and core-quakes or binary mergers, and could become detectable in either gravitational waves or high-energy radiation. Here, we present a comprehensive study of all low-order axisymmetric modes of uniformly and rapidly rotating relativistic stars. Initial stationary configurations are appropriately perturbed and are numerically evolved using an axisymmetric, non-linear relativistic hydrodynamics code, assuming time-independence of the gravitational field (Cowling approximation). The simulations are performed using a high-resolution shock-capturing finite-difference scheme accurate enough to maintain the initial rotation law for a large number of rotational periods, even for stars at the mass-shedding limit. Through Fourier transforms of the time evolution of selected fluid variables, we compute the frequencies of quasi-radial and non-radial modes with spherical harmonic indices l=0, 1, 2 and 3, for a sequence of rotating stars from the non-rotating limit to the mass-shedding limit. The frequencies of the axisymmetric modes are affected significantly by rotation only when the rotation rate exceeds about 50 per cent of the maximum allowed. As expected, at large rotation rates, apparent mode crossings between different modes appear. In addition to the above modes, several axisymmetric inertial modes are also excited in our numerical evolutions.

  16. Advanced Wastewater Treatment Engineering—Investigating Membrane Fouling in both Rotational and Static Membrane Bioreactor Systems Using Empirical Modelling

    PubMed Central

    Paul, Parneet; Jones, Franck Anderson

    2016-01-01

    Advanced wastewater treatment using membranes are popular environmental system processes since they allow reuse and recycling. However, fouling is a key limiting factor and so proprietary systems such as Avanti’s RPU-185 Flexidisks membrane bioreactor (MBR) use novel rotating membranes to assist in ameliorating it. In earlier research, this rotating process was studied by creating a simulation model based on first principles and traditional fouling mechanisms. In order to directly compare the potential benefits of this rotational system, this follow-up study was carried out using Avanti’s newly developed static (non-rotating) Flexidisks MBR system. The results from operating the static pilot unit were simulated and modelled using the rotational fouling model developed earlier however with rotational switching functions turned off and rotational parameters set to a static mode. The study concluded that a rotating MBR system could increase flux throughput when compared against a similar static system. It is thought that although the slowly rotating spindle induces a weak crossflow shear, it is still able to even out cake build up across the membrane surface, thus reducing the likelihood of localised critical flux being exceeded at the micro level and lessening the potential of rapid trans-membrane pressure increases at the macro level. PMID:26742053

  17. Mental rotation training: transfer and maintenance effects on spatial abilities.

    PubMed

    Meneghetti, Chiara; Borella, Erika; Pazzaglia, Francesca

    2016-01-01

    One of the aims of research in spatial cognition is to examine whether spatial skills can be enhanced. The goal of the present study was thus to assess the benefit and maintenance effects of mental rotation training in young adults. Forty-eight females took part in the study: 16 were randomly assigned to receive the mental rotation training (based on comparing pairs of 2D or 3D objects and rotation games), 16 served as active controls (performing parallel non-spatial activities), and 16 as passive controls. Transfer effects to both untrained spatial tasks (testing both object rotation and perspective taking) and visual and verbal tasks were examined. Across the training sessions, the group given mental rotation training revealed benefits in the time it took to make judgments when comparing 3D and 2D objects, but their mental rotation speed did not improve. When compared with the other groups, the mental rotation training group did show transfer effects, however, in tasks other than those practiced (i.e., in object rotation and perspective-taking tasks), and these benefits persisted after 1 month. The training had no effect on visual or verbal tasks. These findings are discussed from the spatial cognition standpoint and with reference to the (rotation) training literature.

  18. Think spatial: the representation in mental rotation is nonvisual.

    PubMed

    Liesefeld, Heinrich R; Zimmer, Hubert D

    2013-01-01

    For mental rotation, introspection, theories, and interpretations of experimental results imply a certain type of mental representation, namely, visual mental images. Characteristics of the rotated representation can be examined by measuring the influence of stimulus characteristics on rotational speed. If the amount of a given type of information influences rotational speed, one can infer that it was contained in the rotated representation. In Experiment 1, rotational speed of university students (10 men, 11 women) was found to be influenced exclusively by the amount of represented orientation-dependent spatial-relational information but not by orientation-independent spatial-relational information, visual complexity, or the number of stimulus parts. As information in mental-rotation tasks is initially presented visually, this finding implies that at some point during each trial, orientation-dependent information is extracted from visual information. Searching for more direct evidence for this extraction, we recorded the EEG of another sample of university students (12 men, 12 women) during mental rotation of the same stimuli. In an early time window, the observed working memory load-dependent slow potentials were sensitive to the stimuli's visual complexity. Later, in contrast, slow potentials were sensitive to the amount of orientation-dependent information only. We conclude that only orientation-dependent information is contained in the rotated representation. (PsycINFO Database Record (c) 2013 APA, all rights reserved).

  19. Material and Stress Rotations: Anticipating the 1992 Landers, CA Earthquake

    NASA Astrophysics Data System (ADS)

    Nur, A. M.

    2014-12-01

    "Rotations make nonsense of the two-dimensional reconstructions that are still so popular among structural geologists". (McKenzie, 1990, p. 109-110) I present a comprehensive tectonic model for the strike-slip fault geometry, seismicity, material rotation, and stress rotation, in which new, optimally oriented faults can form when older ones have rotated about a vertical axis out of favorable orientations. The model was successfully tested in the Mojave region using stress rotation and three independent data sets: the alignment of epicenters and fault plane solutions from the six largest central Mojave earthquakes since 1947, material rotations inferred from paleomagnetic declination anomalies, and rotated dike strands of the Independence dike swarm. The model led not only to the anticipation of the 1992 M7.3 Landers, CA earthquake but also accounts for the great complexity of the faulting and seismicity of this event. The implication of this model for crustal deformation in general is that rotations of material (faults and the blocks between them) and of stress provide the key link between the complexity of faults systems in-situ and idealized mechanical theory of faulting. Excluding rotations from the kinematical and mechanical analysis of crustal deformation makes it impossible to explain the complexity of what geologists see in faults, or what seismicity shows us about active faults. However, when we allow for rotation of material and stress, Coulomb's law becomes consistent with the complexity of faults and faulting observed in situ.

  20. Understanding rotation profile structures in ECH-heated plasmas using nonlinear gyrokinetic simulations

    NASA Astrophysics Data System (ADS)

    Wang, Weixing; Brian, B.; Ethier, S.; Chen, J.; Startsev, E.; Diamond, P. H.; Lu, Z.

    2015-11-01

    A non-diffusive momentum flux connecting edge momentum sources/sinks and core plasma flow is required to establish the off-axis peaked ion rotation profile typically observed in ECH-heated DIII-D plasmas without explicit external momentum input. The understanding of the formation of such profile structures provides an outstanding opportunity to test the physics of turbulence driving intrinsic rotation, and validate first-principles-based gyrokinetic simulation models. Nonlinear, global gyrokinetic simulations of DIII-D ECH plasmas indicate a substantial ITG fluctuation-induced residual stress generated around the region of peaked toroidal rotation, along with a diffusive momentum flux. The residual stress profile shows an anti-gradient, dipole structure, which is critical for accounting for the formation of the peaked rotation profile. It is showed that both turbulence intensity gradient and zonal flow ExB shear contribute to the generation of k// asymmetry needed for residual stress generation. By balancing the simulated residual stress and the momentum diffusion, a rotation profile is calculated. In general, the radial structure of core rotation profile is largely determined by the residual stress profile, while the amplitude of core rotation depends on the edge toroidal rotation velocity, which is determined by edge physics and used as a boundary condition in our model. The calculated core rotation profile is consistent with the experimental measurements. Also discussed is the modification of turbulence-generated Reynolds stress on poloidal rotation in those plasmas. Work supported by U.S. DOE Contract DE-AC02-09-CH11466.

  1. Solar rotational modulations of spectral irradiance and correlations with the variability of total solar irradiance

    NASA Astrophysics Data System (ADS)

    Lee, Jae N.; Cahalan, Robert F.; Wu, Dong L.

    2016-09-01

    Aims: We characterize the solar rotational modulations of spectral solar irradiance (SSI) and compare them with the corresponding changes of total solar irradiance (TSI). Solar rotational modulations of TSI and SSI at wavelengths between 120 and 1600 nm are identified over one hundred Carrington rotational cycles during 2003-2013. Methods: The SORCE (Solar Radiation and Climate Experiment) and TIMED (Thermosphere Ionosphere Mesosphere Energetics and Dynamics)/SEE (Solar EUV Experiment) measured and SATIRE-S modeled solar irradiances are analyzed using the EEMD (Ensemble Empirical Mode Decomposition) method to determine the phase and amplitude of 27-day solar rotational variation in TSI and SSI. Results: The mode decomposition clearly identifies 27-day solar rotational variations in SSI between 120 and 1600 nm, and there is a robust wavelength dependence in the phase of the rotational mode relative to that of TSI. The rotational modes of visible (VIS) and near infrared (NIR) are in phase with the mode of TSI, but the phase of the rotational mode of ultraviolet (UV) exhibits differences from that of TSI. While it is questionable that the VIS to NIR portion of the solar spectrum has yet been observed with sufficient accuracy and precision to determine the 11-year solar cycle variations, the temporal variations over one hundred cycles of 27-day solar rotation, independent of the two solar cycles in which they are embedded, show distinct solar rotational modulations at each wavelength.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moll, Ryan; Garaud, Pascale, E-mail: rmoll@soe.ucsc.edu

    Oscillatory double-diffusive convection (ODDC, more traditionally called semiconvection) is a form of linear double-diffusive instability that occurs in fluids that are unstably stratified in temperature (Schwarzschild unstable), but stably stratified in chemical composition (Ledoux stable). This scenario is thought to be quite common in the interiors of stars and giant planets, and understanding the transport of heat and chemical species by ODDC is of great importance to stellar and planetary evolution models. Fluids unstable to ODDC have a tendency to form convective thermocompositional layers that significantly enhance the fluxes of temperature and chemical composition compared with microscopic diffusion. Although a numbermore » of recent studies have focused on studying properties of both layered and nonlayered ODDC, few have addressed how additional physical processes such as global rotation affect its dynamics. In this work, we study first how rotation affects the linear stability properties of rotating ODDC. Using direct numerical simulations, we then analyze the effect of rotation on properties of layered and nonlayered ODDC, and we study how the angle of the rotation axis with respect to the direction of gravity affects layering. We find that rotating systems can be broadly grouped into two categories based on the strength of rotation. The qualitative behavior in the more weakly rotating group is similar to nonrotating ODDC, but strongly rotating systems become dominated by vortices that are invariant in the direction of the rotation vector and strongly influence transport. We find that whenever layers form, rotation always acts to reduce thermal and compositional transport.« less

  3. Femoral neck radiography: effect of flexion on visualization.

    PubMed

    Garry, Steven C; Jhangri, Gian S; Lambert, Robert G W

    2005-06-01

    To determine whether flexion improves radiographic visualization of the femoral neck when the femur is externally rotated. Five human femora, with varying neck-shaft and anteversion angles, were measured and immobilized. Degree of flexion required to bring the femoral neck horizontal was measured, varying the rotation. Next, one bone was radiographed in 16 positions, varying rotation in 15 degrees and flexion in 10 degrees increments. Radiographs were presented in randomized blinded fashion to 15 staff radiologists for scoring of femoral neck visualization. Following this, all 5 bones were radiographed in 4 positions of rotation and at 0 degree and 20 degrees flexion, and blinded randomized review of radiographs was repeated. Comparisons between angles and rotations were made using the Mann-Whitney test. The flexion angle required to bring the long axis of the femoral neck horizontal correlated directly with the degree of external rotation (p < 0.05). Visualization of the femoral neck in the extended position progressively deteriorated from 15 degrees internal rotation to 30 degrees external rotation (p < 0.01). However, when 20 degrees flexion was applied to bones in external rotation, visualization significantly improved at 15 degrees (p < 0.05) and 30 degrees (p < 0.01). Flexion of the externally rotated femur can bring the femoral neck into horizontal alignment, and a relatively small amount (20 degrees) of flexion can significantly improve radiographic visualization. This manoeuvre could be useful for radiography of the femoral neck when initial radiographs are inadequate because of external rotation of the leg.

  4. Heart disease and left ventricular rotation - a systematic review and quantitative summary.

    PubMed

    Phillips, Aaron A; Cote, Anita T; Bredin, Shannon S D; Warburton, Darren E R

    2012-06-24

    Left ventricular (LV) rotation is increasingly examined in those with heart disease. The available evidence measuring LV rotation in those with heart diseases has not been systematically reviewed. To review systematically the evidence measuring LV rotational changes in various heart diseases compared to healthy controls, literature searches were conducted for appropriate articles using several electronic databases (e.g., MEDLINE, EMBASE). All randomized-controlled trials, prospective cohort and case-controlled studies that assessed LV rotation in relation to various heart conditions were included. Three independent reviewers evaluated each investigation's quality using validated scales. Results were tabulated and levels of evidence assigned. A total of 1,782 studies were found through the systematic literature search. Upon review of the articles, 47 were included. The articles were separated into those investigating changes in LV rotation in participants with: aortic stenosis, myocardial infarction, hypertrophic cardiomyopathy, dilated cardiomyopathy, non-compaction, restrictive cardiomyopathy/ constrictive pericarditis, heart failure, diastolic dysfunction, heart transplant, implanted pacemaker, coronary artery disease and cardiovascular disease risk factors. Evidence showing changes in LV rotation due to various types of heart disease was supported by evidence with limited to moderate methodological quality. Despite a relatively low quality and volume of evidence, the literature consistently shows that heart disease leads to marked changes in LV rotation, while rotational systolic-diastolic coupling is preserved. No prognostic information exists on the potential value of rotational measures of LV function. The literature suggests that measures of LV rotation may aid in diagnosing subclinical aortic stenosis and diastolic dysfunction.

  5. Two routes to expertise in mental rotation.

    PubMed

    Provost, Alexander; Johnson, Blake; Karayanidis, Frini; Brown, Scott D; Heathcote, Andrew

    2013-01-01

    The ability to imagine objects undergoing rotation (mental rotation) improves markedly with practice, but an explanation of this plasticity remains controversial. Some researchers propose that practice speeds up the rate of a general-purpose rotation algorithm. Others maintain that performance improvements arise through the adoption of a new cognitive strategy-repeated exposure leads to rapid retrieval from memory of the required response to familiar mental rotation stimuli. In two experiments we provide support for an integrated explanation of practice effects in mental rotation by combining behavioral and EEG measures in a way that provides more rigorous inference than is available from either measure alone. Before practice, participants displayed two well-established signatures of mental rotation: Both response time and EEG negativity increased linearly with rotation angle. After extensive practice with a small set of stimuli, both signatures of mental rotation had all but disappeared. In contrast, after the same amount of practice with a much larger set both signatures remained, even though performance improved markedly. Taken together, these results constitute a reversed association, which cannot arise from variation in a single cause, and so they provide compelling evidence for the existence of two routes to expertise in mental rotation. We also found novel evidence that practice with the large but not the small stimulus set increased the magnitude of an early visual evoked potential, suggesting increased rotation speed is enabled by improved efficiency in extracting three-dimensional information from two-dimensional stimuli. © 2013 Cognitive Science Society, Inc.

  6. Solar Rotational Modulations of Spectral Irradiance and Correlations with the Variability of Total Solar Irradiance

    NASA Technical Reports Server (NTRS)

    Lee, Jae N.; Cahalan, Robert F.; Wu, Dong L.

    2016-01-01

    Aims: We characterize the solar rotational modulations of spectral solar irradiance (SSI) and compare them with the corresponding changes of total solar irradiance (TSI). Solar rotational modulations of TSI and SSI at wavelengths between 120 and 1600 nm are identified over one hundred Carrington rotational cycles during 2003-2013. Methods: The SORCE (Solar Radiation and Climate Experiment) and TIMED (Thermosphere Ionosphere Mesosphere Energetics and Dynamics)/SEE (Solar EUV Experiment) measured and SATIRE-S modeled solar irradiances are analyzed using the EEMD (Ensemble Empirical Mode Decomposition) method to determine the phase and amplitude of 27-day solar rotational variation in TSI and SSI. Results: The mode decomposition clearly identifies 27-day solar rotational variations in SSI between 120 and 1600 nm, and there is a robust wavelength dependence in the phase of the rotational mode relative to that of TSI. The rotational modes of visible (VIS) and near infrared (NIR) are in phase with the mode of TSI, but the phase of the rotational mode of ultraviolet (UV) exhibits differences from that of TSI. While it is questionable that the VIS to NIR portion of the solar spectrum has yet been observed with sufficient accuracy and precision to determine the 11-year solar cycle variations, the temporal variations over one hundred cycles of 27-day solar rotation, independent of the two solar cycles in which they are embedded, show distinct solar rotational modulations at each wavelength.

  7. Rotation Frequencies of Small Jovian Trojan Asteroids: An Excess of Slow Rotators

    NASA Astrophysics Data System (ADS)

    French, Linda M.; Stephens, Robert D.; James, David J.; Coley, Daniel; Connour, Kyle

    2015-11-01

    Several lines of evidence support a common origin for, and possible hereditary link between, cometary nuclei and jovian Trojan asteroids. Due to their distance and low albedos, few comet-sized Trojans have been studied. We discuss the rotation properties of Jovian Trojan asteroids less than 30 km in diameter. Approximately half the 131 objects discussed here were studied using densely sampled lightcurves (French et al. 2015a, b); Stephens et al. 2015), and the other half were sparse lightcurves obtained by the Palomar Transient Factory (PTF; Waszcazk et al. 2015).A significant fraction (~40%) of the objects in the ground-based sample rotate slowly (P > 24h), with measured periods as long as 375 h (Warner and Stephens 2011). The PTF data show a similar excess of slow rotators. Only 5 objects in the combined data set have rotation periods of less than six hours. Three of these fast rotators were contained in the data set of French et al. these three had a geometric mean rotation period of 5.29 hours. A prolate spheroid held together by gravity rotating with this period would have a critical density of 0.43 gm/cm3, a density similar to that of comets (Lamy et al. 2004).Harris et al. (2012) and Warner et al. (2011) have explored the possible effects on asteroid rotational statistics with the results from wide-field surveys. We will examine Trojan rotation statistics with and without the results from the PTF.

  8. 14 CFR 33.74 - Continued rotation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Design and Construction; Turbine Aircraft Engines § 33.74 Continued rotation. If any of the engine main rotating systems continue to rotate after the engine is shutdown for any reason...

  9. 14 CFR 33.74 - Continued rotation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: AIRCRAFT ENGINES Design and Construction; Turbine Aircraft Engines § 33.74 Continued rotation. If any of the engine main rotating systems continue to rotate after the engine is shutdown for any reason...

  10. A Study about the Taboo of Rotation Timing for the Flapping Wing Flight

    NASA Astrophysics Data System (ADS)

    Wang, An-Bang; Hsueh, Chia-Hsien; Chen, Shih-Shen

    2004-11-01

    Influence of rotation timing for flapping wing flight on the flying lift has been experimentally investigated in this study. Since the insects cannot extend and shrink their wings like birds, the rotation timing of wings becomes the major influential factor to affect the flying lift of the flapping wing flight. The results reveal that rotation timing has significant influence on the flying lift. The averaged flying lift increases for high rotation wing velocity. Based on the comparisons of flying lift, too late A-rotation (connecting from wing downward motion to upward one) is the most serious taboo for the motion design of the micro air vehicles with flapping wings. Too late B-rotation (connection from upward motion to downward one) should also be avoided.

  11. Report of the IAU/IAG Working Group on cartographic coordinates and rotational elements: 2006

    USGS Publications Warehouse

    Seidelmann, P.K.; Archinal, B.A.; A'Hearn, M.F.; Conrad, A.; Consolmagno, G.J.; Hestroffer, D.; Hilton, J.L.; Krasinsky, G.A.; Neumann, G.; Oberst, J.; Stooke, P.; Tedesco, E.F.; Tholen, D.J.; Thomas, P.C.; Williams, I.P.

    2007-01-01

    Every three years the IAU/IAG Working Group on Cartographic Coordinates and Rotational Elements revises tables giving the directions of the poles of rotation and the prime meridians of the planets, satellites, minor planets, and comets. This report introduces improved values for the pole and rotation rate of Pluto, Charon, and Phoebe, the pole of Jupiter, the sizes and shapes of Saturn satellites and Charon, and the poles, rotation rates, and sizes of some minor planets and comets. A high precision realization for the pole and rotation rate of the Moon is provided. The expression for the Sun's rotation has been changed to be consistent with the planets and to account for light travel time ?? 2007 Springer Science+Business Media B.V.

  12. Detection of Sound Image Movement During Horizontal Head Rotation

    PubMed Central

    Ohba, Kagesho; Iwaya, Yukio; Suzuki, Yôiti

    2016-01-01

    Movement detection for a virtual sound source was measured during the listener’s horizontal head rotation. Listeners were instructed to do head rotation at a given speed. A trial consisted of two intervals. During an interval, a virtual sound source was presented 60° to the right or left of the listener, who was instructed to rotate the head to face the sound image position. Then in one of a pair of intervals, the sound position was moved slightly in the middle of the rotation. Listeners were asked to judge the interval in a trial during which the sound stimuli moved. Results suggest that detection thresholds are higher when listeners do head rotation. Moreover, this effect was found to be independent of the rotation velocity. PMID:27698993

  13. Notes on rotating turbulence

    NASA Technical Reports Server (NTRS)

    Zeman, Otto

    1994-01-01

    This work investigates the turbulent constitutive relation when turbulence is subjected to solid body rotation. Laws regarding spectra and asymptotic decay of rotating homogeneous turbulence were confirmed through large-eddy simulation (LES) computations. Rotating turbulent flows exist in many industrial, geophysical, and astrophysical applications. From Lagrangian analysis a relation between turbulent stress and strain in rotating homogeneous turbulence was inferred. This relation was used to derive the spectral energy flux and, ultimately, the energy spectrum form. If the rotation wavenumber k(sub Omega) lies in the inertial subrange, then for wavenumbers less than k(sub Omega) the turbulence motions are affected by rotation and the energy spectrum slope is modified. Energy decay laws inferred in other reports and the present results suggest a modification of the epsilon model equation and eddy viscosity in k-epsilon models.

  14. Some current research in rotating-disc systems.

    PubMed

    Owen, J M; Wilson, M

    2001-05-01

    Rotating-disc systems are used to model the flow and heat transfer that occurs inside the cooling-air systems of gas-turbine engines. In this paper, recent computational and experimental research in three systems is discussed: rotor-stator systems, rotating cavities with superposed flow and buoyancy-induced flow in a rotating cavity. Discussion of the first two systems concentrates respectively on pre-swirl systems and rotating cavities with a peripheral inflow and outflow of cooling air. Buoyancy-induced flow in a rotating cavity is one of the most difficult problems facing computationalists and experimentalists, and there are similarities between the circulation in the Earth's atmosphere and the flow inside gas-turbine rotors. For this case, results are presented for heat transfer in sealed annuli and in rotating cavities with an axial throughflow of cooling air.

  15. Stellar Rotation: New Insight from CoRoT

    NASA Astrophysics Data System (ADS)

    Catala, C.; Goupil, M. J.; Michel, E.; Baglin, A.; de Medeiros, J. Renan; Gondoin, Ph.

    2009-02-01

    We present an overview of the new insight provided by the CoRoT satellite on stellar rotation. Thanks to its ultra-high precision, high duty cycle, long photometric monitoring of thousands of stars, CoRoT gives us a powerful tool to study stellar rotational modulation, and therefore to measure stellar rotational periods and to study active structures at the surface of stars. This paper presents preliminary results concerning this type of study. CoRoT will also provide us with an insight of internal stellar rotation via the measurement and exploitation of rotational splittings of oscillation modes. This approach to stellar rotation with CoRoT will require a careful analysis of the oscillation power spectra, which is in progress, but prospects for such measurements are presented.

  16. A compact rotating dilution refrigerator

    NASA Astrophysics Data System (ADS)

    Fear, M. J.; Walmsley, P. M.; Chorlton, D. A.; Zmeev, D. E.; Gillott, S. J.; Sellers, M. C.; Richardson, P. P.; Agrawal, H.; Batey, G.; Golov, A. I.

    2013-10-01

    We describe the design and performance of a new rotating dilution refrigerator that will primarily be used for investigating the dynamics of quantized vortices in superfluid 4He. All equipment required to operate the refrigerator and perform experimental measurements is mounted on two synchronously driven, but mechanically decoupled, rotating carousels. The design allows for relative simplicity of operation and maintenance and occupies a minimal amount of space in the laboratory. Only two connections between the laboratory and rotating frames are required for the transmission of electrical power and helium gas recovery. Measurements on the stability of rotation show that rotation is smooth to around 10-3 rad s-1 up to angular velocities in excess of 2.5 rad s-1. The behavior of a high-Q mechanical resonator during rapid changes in rotation has also been investigated.

  17. Imagining physically impossible self-rotations: geometry is more important than gravity.

    PubMed

    Creem, S H; Wraga, M; Proffitt, D R

    2001-08-01

    Previous studies found that it is easier for observers to spatially update displays during imagined self-rotation versus array rotation. The present study examined whether either the physics of gravity or the geometric relationship between the viewer and array guided this self-rotation advantage. Experiments 1-3 preserved a real or imagined orthogonal relationship between the viewer and the array, requiring a rotation in the observer's transverse plane. Despite imagined self-rotations that defied gravity, a viewer advantage remained. Without this orthogonal relationship (Experiment 4), the viewer advantage was lost. We suggest that efficient transformation of the egocentric reference frame relies on the representation of body-environment relations that allow rotation around the observer's principal axis. This efficiency persists across different and conflicting physical and imagined postures.

  18. Imagining physically impossible self-rotations: geometry is more important than gravity

    NASA Technical Reports Server (NTRS)

    Creem, S. H.; Wraga, M.; Proffitt, D. R.; Kaiser, M. K. (Principal Investigator)

    2001-01-01

    Previous studies found that it is easier for observers to spatially update displays during imagined self-rotation versus array rotation. The present study examined whether either the physics of gravity or the geometric relationship between the viewer and array guided this self-rotation advantage. Experiments 1-3 preserved a real or imagined orthogonal relationship between the viewer and the array, requiring a rotation in the observer's transverse plane. Despite imagined self-rotations that defied gravity, a viewer advantage remained. Without this orthogonal relationship (Experiment 4), the viewer advantage was lost. We suggest that efficient transformation of the egocentric reference frame relies on the representation of body-environment relations that allow rotation around the observer's principal axis. This efficiency persists across different and conflicting physical and imagined postures.

  19. In-line rotating capacitive torque sensor

    DOEpatents

    Kronberg, J.W.

    1991-09-10

    Disclosed are a method and apparatus for measuring torques developed along a rotating mechanical assembly comprising a rotating inner portion and a stationary outer portion. The rotating portion has an electrically-conductive flexing section fitted between two coaxial shafts in a configuration which varies radially in accordance with applied torque. The stationary portion comprises a plurality of conductive plates forming a surface concentric with and having a diameter slightly larger than the diameter of the rotating portion. The capacitance between the outer, nonrotating and inner, rotating portion varies with changes in the radial configuration of the rotating portion. Signal output varies approximately linearly with torque for small torques, nonlinearly for larger torques. The sensor is preferably surrounded by a conductive shell to minimize electrical interference from external sources. 18 figures.

  20. Non-contact measurement of rotation angle with solo camera

    NASA Astrophysics Data System (ADS)

    Gan, Xiaochuan; Sun, Anbin; Ye, Xin; Ma, Liqun

    2015-02-01

    For the purpose to measure a rotation angle around the axis of an object, a non-contact rotation angle measurement method based on solo camera was promoted. The intrinsic parameters of camera were calibrated using chessboard on principle of plane calibration theory. The translation matrix and rotation matrix between the object coordinate and the camera coordinate were calculated according to the relationship between the corners' position on object and their coordinates on image. Then the rotation angle between the measured object and the camera could be resolved from the rotation matrix. A precise angle dividing table (PADT) was chosen as the reference to verify the angle measurement error of this method. Test results indicated that the rotation angle measurement error of this method did not exceed +/- 0.01 degree.

  1. Opioid Rotation in Cancer Pain Treatment.

    PubMed

    Schuster, Michael; Bayer, Oliver; Heid, Florian; Laufenberg-Feldmann, Rita

    2018-03-02

    Rotating several different WHO level III opioid drugs is a therapeutic option for patients with chronic cancer-related pain who suffer from inadequate analgesia and/or intolerable side effects. The evidence favoring opioid rotation is controversial, and the current guidelines in Germany and other countries contain only weak recommendations for it. This review is based on pertinent publications retrieved by a systematic review of the literature on opioid rotation for adult patients with chronic cancerrelated pain who are regularly taking WHO level III opioids by the oral or trans - dermal route. 9 individual studies involving a total of 725 patients were included in the analysis, and 3 previous systematic reviews of studies involving a total of 2296 patients were also analyzed. Morphine, oxycodone, fentanyl, hydromorphone, and buprenorphine were used as first-line opioid drugs, and hydromorphone, bupre - norphine, tapentadol, fentanyl, morphine, oxymorphone, and methadone were used as second-line opioid drugs. In all of the studies, pain control was achieved for 14 days after each rotation. In most of them, the dose of the new drug introduced in each rotation needed to be increased above the dose initially calculated from a rotation ratio, with the exception of rotations to methadone. The frequency of side effects was only rarely lessened, but patients largely considered the result of opioid rotation to be positive. No particular opioid drug was found to be best. Opioid rotation can improve analgesia and patient satisfaction. The success of opioid rotation appears to depend on the magnitude of the initial dose, among other factors. Tables of equianalgesic doses should be considered no more than a rough guide for determining the dose of the new drug. Rotations to methadone should be carried out under clinical supervision in experienced hands.

  2. Assessment of the Rotation Motion at the Papillary Muscle Short-Axis Plane with Normal Subjects by Two-Dimensional Speckle Tracking Imaging: A Basic Clinical Study

    PubMed Central

    Ni, Xian-Da; Huang, Jun; Hu, Yuan-Ping; Xu, Rui; Yang, Wei-Yu; Zhou, Li-Ming

    2013-01-01

    Background The aim of this study was to observe the rotation patterns at the papillary muscle plane in the Left Ventricle(LV) with normal subjects using two-dimensional speckle tracking imaging(2D-STI). Methods We acquired standard of the basal, the papillary muscle and the apical short-axis images of the LV in 64 subjects to estimate the LV rotation motion by 2D-STI. The rotational degrees at the papillary muscle short-axis plane were measured at 15 different time points in the analysis of two heart cycles. Results There were counterclockwise rotation, clockwise rotation, and counterclockwise to clockwise rotation at the papillary muscle plane in the LV with normal subjects, respectively. The ROC analysis of the rotational degrees was performed at the papillary muscle short-axis plane at the peak LV torsion for predicting whether the turnaround point of twist to untwist motion pattern was located at the papillary muscle level. Sensitivity and specificity were 97% and 67%, respectively, with a cut-off value of 0.34°, and an area under the ROC curve of 0.8. At the peak LV torsion, there was no correlation between the rotational degrees at the papillary muscle short-axis plane and the LVEF in the normal subjects(r = 0.000, p = 0.998). Conclusions In the study, we conclude that there were three rotation patterns at the papillary muscle short-axis levels, and the transition from basal clockwise rotation to apical counterclockwise rotation is located at the papillary muscle level. PMID:24376634

  3. The effect of trunk rotation during shoulder exercises on the activity of the scapular muscle and scapular kinematics.

    PubMed

    Yamauchi, Taishi; Hasegawa, Satoshi; Matsumura, Aoi; Nakamura, Masatoshi; Ibuki, Satoko; Ichihashi, Noriaki

    2015-06-01

    In patients with shoulder disease, kinetic chain exercises including hip or trunk movement are recommended. However, the actual muscle activation and scapular kinematics of these exercises are not known. The purpose of this study was to examine the effect of trunk rotation on shoulder exercises that are devised to improve scapular function. Thirteen healthy young men participated in this study. Scaption, external rotation in the first and second positions, and prone scapular retraction at 45°, 90°, and 145° of shoulder abduction were performed with and without trunk rotation. Electromyography was used to assess the scapular muscle activity of the upper trapezius (UT), middle trapezius (MT), lower trapezius (LT), and serratus anterior (SA), and electromagnetic motion capture was used to assess scapular motion. The muscle activity ratio, which is the activity of the UT to the MT, LT, and SA, was calculated. These data were compared between 2 conditions (with and without trunk rotation) for each exercise. Adding trunk rotation to scaption, the first external rotation, and the second external rotation significantly increased scapular external rotation and posterior tilt, and all 3 exercises increased LT activation. In addition, trunk rotation with scapular retraction at 90° and 145° of shoulder abduction significantly decreased the UT/LT ratio. Our findings suggest that shoulder exercises with trunk rotation in this study may be effective in patients who have difficulty in enhancing LT activity and suppressing excessive activation of the UT or in cases in which a decreased scapular external rotation or posterior tilt is observed. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. The functional role of dorso-lateral premotor cortex during mental rotation: an event-related fMRI study separating cognitive processing steps using a novel task paradigm.

    PubMed

    Lamm, Claus; Windischberger, Christian; Moser, Ewald; Bauer, Herbert

    2007-07-15

    Subjects deciding whether two objects presented at angular disparity are identical or mirror versions of each other usually show response times that linearly increase with the angle between objects. This phenomenon has been termed mental rotation. While there is widespread agreement that parietal cortex plays a dominant role in mental rotation, reports concerning the involvement of motor areas are less consistent. From a theoretical point of view, activation in motor areas suggests that mental rotation relies upon visuo-motor rather than visuo-spatial processing alone. However, the type of information that is processed by motor areas during mental rotation remains unclear. In this study we used event-related fMRI to assess whether activation in parietal and dorsolateral premotor areas (dPM) during mental rotation is distinctively related to processing spatial orientation information. Using a newly developed task paradigm we explicitly separated the processing steps (encoding, mental rotation proper and object matching) required by mental rotation tasks and additionally modulated the amount of spatial orientation information that had to be processed. Our results show that activation in dPM during mental rotation is not strongly modulated by the processing of spatial orientation information, and that activation in dPM areas is strongest during mental rotation proper. The latter finding suggests that dPM is involved in more generalized processes such as visuo-spatial attention and movement anticipation. We propose that solving mental rotation tasks is heavily dependent upon visuo-motor processes and evokes neural processing that may be considered as an implicit simulation of actual object rotation.

  5. Predicting Rotator Cuff Tears Using Data Mining and Bayesian Likelihood Ratios

    PubMed Central

    Lu, Hsueh-Yi; Huang, Chen-Yuan; Su, Chwen-Tzeng; Lin, Chen-Chiang

    2014-01-01

    Objectives Rotator cuff tear is a common cause of shoulder diseases. Correct diagnosis of rotator cuff tears can save patients from further invasive, costly and painful tests. This study used predictive data mining and Bayesian theory to improve the accuracy of diagnosing rotator cuff tears by clinical examination alone. Methods In this retrospective study, 169 patients who had a preliminary diagnosis of rotator cuff tear on the basis of clinical evaluation followed by confirmatory MRI between 2007 and 2011 were identified. MRI was used as a reference standard to classify rotator cuff tears. The predictor variable was the clinical assessment results, which consisted of 16 attributes. This study employed 2 data mining methods (ANN and the decision tree) and a statistical method (logistic regression) to classify the rotator cuff diagnosis into “tear” and “no tear” groups. Likelihood ratio and Bayesian theory were applied to estimate the probability of rotator cuff tears based on the results of the prediction models. Results Our proposed data mining procedures outperformed the classic statistical method. The correction rate, sensitivity, specificity and area under the ROC curve of predicting a rotator cuff tear were statistical better in the ANN and decision tree models compared to logistic regression. Based on likelihood ratios derived from our prediction models, Fagan's nomogram could be constructed to assess the probability of a patient who has a rotator cuff tear using a pretest probability and a prediction result (tear or no tear). Conclusions Our predictive data mining models, combined with likelihood ratios and Bayesian theory, appear to be good tools to classify rotator cuff tears as well as determine the probability of the presence of the disease to enhance diagnostic decision making for rotator cuff tears. PMID:24733553

  6. Deficiency in Mental Rotation of Upper and Lower-Limbs in Patients With Multiple Sclerosis and Its Relation With Cognitive Functions.

    PubMed

    Azin, Mahdieh; Zangiabadi, Nasser; Moghadas Tabrizi, Yousef; Iranmanesh, Farhad; Baneshi, Mohammad Reza

    2016-08-01

    Mental rotation is a cognitive motor process which was impaired in different neurologic disorders. We investigated whether there were deficits in response pattern, reaction time and response accuracy rate of mental rotation in multiple sclerosis (MS) patients compared to healthy subjects and whether cognitive dysfunctions in MS patients were correlated with mental rotation deficits. Moreover, we showed whether there was a difference between upper and lower-limbs mental rotation in MS patients. Thirty-five MS patients and 25 healthy subjects performed hand mental rotation (HMR) and foot mental rotation (FMR) tasks. Visual information processing speed, spatial learning and memory ability, and visuospatial processing were assessed by Symbol Digit Modalities Test (SDMT), Brief Visuospatial Memory Test-Revised (BVMT-R), and Judgment of Line Orientation Test (JLO) respectively in MS patients. Reaction time for both hand and foot stimuli increased, and response accuracy rate for hand stimuli decreased in MS patients compared to healthy subjects, but response pattern of mental rotation in MS patients persisted. Similar to healthy subjects, MS patients performed upper-limbs mental rotation more easily than a lower-limbs mental rotation with more speed and response accuracy rate. Reaction time and response accuracy rate were correlated with the mentioned cognitive functions. MS patients made use of the correct response pattern for problem solving of increasing orientation from upright stimuli. Reaction time and response accuracy rate altered in these patients and this alteration might occur along with impairment in motor planning. Subjects' better responding to hand stimuli was due to more familiarity with hand stimuli. The correlation of mental rotation ability with cognitive functions indicates the possible role of cognitive functions in mental rotation.

  7. Away Rotations and Matching in Integrated Plastic Surgery Residency: Applicant and Program Director Perspectives.

    PubMed

    Drolet, Brian C; Brower, Jonathan P; Lifchez, Scott D; Janis, Jeffrey E; Liu, Paul Y

    2016-04-01

    Although nearly all medical students pursuing integrated plastic surgery residency participate in elective rotations away from their home medical school, the value and costs of these "away" rotations have not been well studied. The authors surveyed all integrated plastic surgery program directors and all applicants in the 2015 National Residency Matching Program. Forty-two program directors and 149 applicants (64 percent and 70 percent response rate, respectively) completed the survey. Applicants reported 13.7 weeks spent on plastic surgery rotations during medical school, including a mean of 9.2 weeks on away rotations. Average reported cost for away rotations was $3591 per applicant. Both applicants and program directors most commonly reported "making a good impression" (44.6 percent and 36.6 percent, respectively) or finding a "good-fit" program (27.7 percent and 48.8 percent, respectively) as the primary goal for away rotations. Almost all applicants (91.1 percent) believed an away rotation made them more competitive for matching to a program at which they rotated. Program directors ranked a strong away rotation performance as the most important residency selection criterion. Twenty-seven percent of postgraduate year-1 positions were filled by an away rotatorm and an additional 17 percent were filled by a home medical student. Away rotations appear to be mutually beneficial for applicants and programs in helping to establish a good fit between students and training programs through an extended interaction with the students, residents, and faculty. In addition, making a good impression on a senior elective rotation (home or away) may improve an applicant's chance of matching to a residency program.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zaorsky, Nicholas G.; Malatesta, Theresa M.; Den, Robert B.

    Purpose: Few medical students are given proper clinical training in oncology, much less radiation oncology. We attempted to assess the value of adding a radiation oncology clinical rotation to the medical school curriculum. Methods and Materials: In July 2010, Jefferson Medical College began to offer a 3-week radiation oncology rotation as an elective course for third-year medical students during the core surgical clerkship. During 2010 to 2012, 52 medical students chose to enroll in this rotation. The rotation included outpatient clinics, inpatient consults, didactic sessions, and case-based presentations by the students. Tests of students' knowledge of radiation oncology were administeredmore » anonymously before and after the rotation to evaluate the educational effectiveness of the rotation. Students and radiation oncology faculty were given surveys to assess feedback about the rotation. Results: The students' prerotation test scores had an average of 64% (95% confidence interval [CI], 61-66%). The postrotation test scores improved to an average of 82% (95% CI, 80-83%; 18% absolute improvement). In examination question analysis, scores improved in clinical oncology from 63% to 79%, in radiobiology from 70% to 77%, and in medical physics from 62% to 88%. Improvements in all sections but radiobiology were statistically significant. Students rated the usefulness of the rotation as 8.1 (scale 1-9; 95% CI, 7.3-9.0), their understanding of radiation oncology as a result of the rotation as 8.8 (95% CI, 8.5-9.1), and their recommendation of the rotation to a classmate as 8.2 (95% CI, 7.6-9.0). Conclusions: Integrating a radiation oncology clinical rotation into the medical school curriculum improves student knowledge of radiation oncology, including aspects of clinical oncology, radiobiology, and medical physics. The rotation is appreciated by both students and faculty.« less

  9. Hypertrophy of the extra-articular tendon of the long head of biceps correlates with the location and size of a rotator cuff tear.

    PubMed

    Takahashi, N; Sugaya, H; Matsuki, K; Miyauchi, H; Matsumoto, M; Tokai, M; Onishi, K; Hoshika, S; Ueda, Y

    2017-06-01

    The aim of this study was to assess hypertrophy of the extra-articular tendon of the long head of biceps (LHB) in patients with a rotator cuff tear. The study involved 638 shoulders in 334 patients (175 men, 159 women, mean age 62.6 years; 25 to 81) with unilateral symptomatic rotator cuff tears. The cross-sectional area (CSA) of the LHB tendon in the bicipital groove was measured pre-operatively in both shoulders using ultrasound. There were 154 asymptomatic rotator cuff tears in the contralateral shoulder. Comparisons were made between those with a symptomatic tear, an asymptomatic tear and those with no rotator cuff tear. In the affected shoulders, the CSAs were compared in relation to the location and size of the rotator cuff tear. The mean CSA was 21.0 mm 2 (4 to 71) in those with a symptomatic rotator cuff tear, 19.9 mm 2 (4 to 75) in those with an asymptomatic rotator cuff tear and 14.1 mm 2 (5 to 43) in those with no rotator cuff tear. The mean CSA in patients with both symptomatic and asymptomatic rotator cuff tears was significantly larger than in those with no rotator cuff tear (p < 0.001). In the affected shoulders, there were significant differences between patients with more than a medium sized posterosuperior cuff tear and those with an antero-superior cuff tear. Regardless of the symptoms, there was significant hypertrophy of the extra-articular LHB tendon in patients with a rotator cuff tear. The values were significantly related to the size of the tear. Cite this article: Bone Joint J 2017;99-B:806-11. ©2017 The British Editorial Society of Bone & Joint Surgery.

  10. Adaptive Changes in the Perception of Fast and Slow Movement at Different Head Positions.

    PubMed

    Panichi, Roberto; Occhigrossi, Chiara; Ferraresi, Aldo; Faralli, Mario; Lucertini, Marco; Pettorossi, Vito E

    2017-05-01

    This paper examines the subjective sense of orientation during asymmetric body rotations in normal subjects. Self-motion perception was investigated in 10 healthy individuals during asymmetric whole-body rotation with different head orientations. Both on-vertical axis and off-vertical axis rotations were employed. Subjects tracked a remembered earth-fixed visual target while rotating in the dark for four cycles of asymmetric rotation (two half-sinusoidal cycles of the same amplitude, but of different duration). The rotations induced a bias in the perception of velocity (more pronounced with fast than with slow motion). At the end of rotation, a marked target position error (TPE) was present. For the on-vertical axis rotations, the TPE was no different if the rotations were performed with a 30° nose-down, a 60° nose-up, or a 90° side-down head tilt. With off-vertical axis rotations, the simultaneous activation of the semicircular canals and otolithic receptors produced a significant increase of TPE for all head positions. This difference between on-vertical and off-vertical axis rotation was probably partly due to the vestibular transfer function and partly due to different adaptation to the speed of rotation. Such a phenomenon might be generated in different components of the vestibular system. The adaptive process enhancing the perception of dynamic movement around the vertical axis is not related to the specific semicircular canals that are activated; the addition of an otolithic component results in a significant increase of the TPE.Panichi R, Occhigrossi C, Ferraresi A, Faralli M, Lucertini M, Pettorossi VE. Adaptive changes in the perception of fast and slow movement at different head positions. Aerosp Med Hum Perform. 2017; 88(5):463-468.

  11. Analysis of rotation sensor data from the SINAPS@ Kefalonia (Greece) post-seismic experiment—link to surface geology and wavefield characteristics

    NASA Astrophysics Data System (ADS)

    Sbaa, Sarah; Hollender, Fabrice; Perron, Vincent; Imtiaz, Afifa; Bard, Pierre-Yves; Mariscal, Armand; Cochard, Alain; Dujardin, Alain

    2017-09-01

    Although rotational seismology has progressed in recent decades, the links between rotational ground motion and site soil conditions are poorly documented. New experiments were performed on Kefalonia Island (Greece) following two large earthquakes ( M W = 6.0, M W = 5.9) in early 2014 on two well-characterized sites (soft soil, V S30 250 m/s; rock, V S30 830 m/s, V S30 being harmonic average shear-wave velocity between 0 and 30 m depth). These earthquakes led to large six-component (three translations and three rotations) datasets of hundreds of well-recorded events. The relationship between peak translational acceleration versus peak rotational velocity is found sensitive to the site conditions mainly for the rotation around the vertical axis (torsion; dominated by Love waves): the stiffer the soil, the lower the torsion, for a given level of translational acceleration. For rotation around the horizontal axes (rocking; dominated by Rayleigh waves), this acceleration/rotation relationship exhibits much weaker differences between soft and rock sites. Using only the rotation sensor, an estimate of the Love-to-Rayleigh energy ratios could be carried out and provided the same results as previous studies that have analyzed the Love- and Rayleigh-wave energy proportions using data from translational arrays deployed at the same two sites. The coupling of translational and rotational measurements appears to be useful, not only for direct applications of engineering seismology, but also to investigate the composition of the wavefield, while avoiding deployment of dense arrays. The availability of new, low-noise rotation sensors that are easy to deploy in the field is of great interest and should extend the use of rotation sensors and expand their possible applications.[Figure not available: see fulltext.

  12. Pelvic step: the contribution of horizontal pelvis rotation to step length in young healthy adults walking on a treadmill.

    PubMed

    Liang, Bo Wei; Wu, Wen Hua; Meijer, Onno G; Lin, Jian Hua; Lv, Go Rong; Lin, Xiao Cong; Prins, Maarten R; Hu, Hai; van Dieën, Jaap H; Bruijn, Sjoerd M

    2014-01-01

    Transverse plane pelvis rotations during walking may be regarded as the "first determinant of gait". This would assume that pelvis rotations increase step length, and thereby reduce the vertical movements of the centre of mass-"the pelvic step". We analysed the pelvic step using 20 healthy young male subjects, walking on a treadmill at 1-5 km/h, with normal or big steps. Step length, pelvis rotation amplitude, leg-pelvis relative phase, and the contribution of pelvis rotation to step length were calculated. When speed increased in normal walking, pelvis rotation changed from more out-of-phase to in-phase with the upper leg. Consequently, the contribution of pelvis rotation to step length was negative at lower speeds, switching to positive at 3 km/h. With big steps, leg and pelvis were more in-phase, and the contribution of pelvis rotation to step length was always positive, and relatively large. Still, the overall contribution of pelvis rotations to step length was small, less than 3%. Regression analysis revealed that leg-pelvis relative phase predicted about 60% of the variance of this contribution. The results of the present study suggest that, during normal slow walking, pelvis rotations increase, rather than decrease, the vertical movements of the centre of mass. With large steps, this does not happen, because leg and pelvis are in-phase at all speeds. Finally, it has been suggested that patients with hip flexion limitation may use larger pelvis rotations to increase step length. This, however, may only work as long as the pelvis rotates in-phase with the leg. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Impact of abutment rotation and angulation on marginal fit: theoretical considerations.

    PubMed

    Semper, Wiebke; Kraft, Silvan; Mehrhof, Jurgen; Nelson, Katja

    2010-01-01

    Rotational freedom of various implant positional index designs has been previously calculated. To investigate its clinical relevance, a three-dimensional simulation was performed to demonstrate the influence of rotational displacements of the abutment on the marginal fit of prosthetic superstructures. Idealized abutments with different angulations (0, 5, 10, 15, and 20 degrees) were virtually constructed (SolidWorks Office Premium 2007). Then, rotational displacement was simulated with various degrees of rotational freedom (0.7, 0.95, 1.5, 1.65, and 1.85 degrees). The resulting horizontal displacement of the abutment from the original position was quantified in microns, followed by a simulated pressure-less positioning of superstructures with defined internal gaps (5 µm, 60 µm, and 100 µm). The resulting marginal gap between the abutment and the superstructure was measured vertically with the SolidWorks measurement tool. Rotation resulted in a displacement of the abutment of up to 157 µm at maximum rotation and angulation. Interference of a superstructure with a defined internal gap of 5 µm placed on the abutment resulted in marginal gaps up to 2.33 mm at maximum rotation and angulation; with a 60-µm internal gap, the marginal gaps reached a maximum of 802 µm. Simulation using a superstructure with an internal gap of 100 µm revealed a marginal gap of 162 µm at abutment angulation of 20 degrees and rotation of 1.85 degrees. The marginal gaps increased with the degree of abutment angulation and the extent of rotational freedom. Rotational displacement of the abutment influenced prosthesis misfit. The marginal gaps between the abutment and the superstructure increased with the rotational freedom of the index and the angulation of the abutment.

  14. Do modern total knee replacements improve tibial coverage?

    PubMed

    Meier, Malin; Webb, Jonathan; Collins, Jamie E; Beckmann, Johannes; Fitz, Wolfgang

    2018-01-25

    The purpose of the present study is to compare newer designs of various symmetric and asymmetric tibial components and measure tibial bone coverage using the rotational safe zone defined by two commonly utilized anatomic rotational landmarks. Computed tomography scans (CT scans) of one hundred consecutive patients scheduled for total knee arthroplasty were obtained pre-operatively. A virtual proximal tibial cut was performed and two commonly used rotational axes were added for each image: the medio-lateral axis (ML-axis) and the medial 1/3 tibial tubercle axis (med-1/3-axis). Different symmetric and asymmetric implant designs were then superimposed in various rotational positions for best cancellous and cortical coverage. The images were imported to a public domain imaging software, and cancellous and cortical bone coverage was computed for each image, with each implant design in various rotational positions. One single implant type could not be identified that provided the best cortical and cancellous coverage of the tibia, irrespective of using the med-1/3-axis or the ML-axis for rotational alignment. However, it could be confirmed that the best bone coverage was dependent on the selected rotational landmark. Furthermore, improved bone coverage was observed when tibial implant positions were optimized between the two rotational axes. Tibial coverage is similar for symmetric and asymmetric designs, but depends on the rotational landmark for which the implant is designed. The surgeon has the option to improve tibial coverage by optimizing placement between the two anatomic rotational alignment landmarks, the medial 1/3 and the ML-axis. Surgeons should be careful assessing intraoperative rotational tibial placement using the described anatomic rotational landmarks to optimize tibial bony coverage without compromising patella tracking. III.

  15. Convergence of linear acceleration and yaw rotation signals on non-eye movement neurons in the vestibular nucleus of macaques.

    PubMed

    Newlands, Shawn D; Abbatematteo, Ben; Wei, Min; Carney, Laurel H; Luan, Hongge

    2018-01-01

    Roughly half of all vestibular nucleus neurons without eye movement sensitivity respond to both angular rotation and linear acceleration. Linear acceleration signals arise from otolith organs, and rotation signals arise from semicircular canals. In the vestibular nerve, these signals are carried by different afferents. Vestibular nucleus neurons represent the first point of convergence for these distinct sensory signals. This study systematically evaluated how rotational and translational signals interact in single neurons in the vestibular nuclei: multisensory integration at the first opportunity for convergence between these two independent vestibular sensory signals. Single-unit recordings were made from the vestibular nuclei of awake macaques during yaw rotation, translation in the horizontal plane, and combinations of rotation and translation at different frequencies. The overall response magnitude of the combined translation and rotation was generally less than the sum of the magnitudes in responses to the stimuli applied independently. However, we found that under conditions in which the peaks of the rotational and translational responses were coincident these signals were approximately additive. With presentation of rotation and translation at different frequencies, rotation was attenuated more than translation, regardless of which was at a higher frequency. These data suggest a nonlinear interaction between these two sensory modalities in the vestibular nuclei, in which coincident peak responses are proportionally stronger than other, off-peak interactions. These results are similar to those reported for other forms of multisensory integration, such as audio-visual integration in the superior colliculus. NEW & NOTEWORTHY This is the first study to systematically explore the interaction of rotational and translational signals in the vestibular nuclei through independent manipulation. The results of this study demonstrate nonlinear integration leading to maximum response amplitude when the timing and direction of peak rotational and translational responses are coincident.

  16. Effects of 6-week sling-based training of the external-rotator muscles on the shoulder profile in elite female high school handball players.

    PubMed

    Genevois, Cyril; Berthier, Philippe; Guidou, Vincent; Muller, Franck; Thiebault, Boris; Rogowski, Isabelle

    2014-11-01

    In women's handball, the large numbers of throws and passes make the shoulder region vulnerable to overuse injuries. Repetitive throwing motions generate imbalance between shoulder internal- and external-rotator muscles. It has not yet been established whether sling-based training can improve shoulder external-rotator muscle strength. This study investigated the effectiveness of a 6-wk strengthening program in improving shoulder functional profile in elite female high school handball players. Crossover study. National elite handball training center. 25 elite female high school handball players. The program, completed twice per week for 6 wk, included sling-based strengthening exercises using a suspension trainer for external rotation with scapular retraction and scapular retraction alone. Maximal shoulder external- and internal-rotation strength, shoulder external- and internal-rotation range of motion (ROM), and maximal throwing velocity were assessed preintervention and postintervention for dominant and nondominant sides. After sling training, external- and internal-rotation strength increased significantly for both sides (P ≤ .001, and P = .004, respectively), with the result that there was no significant change in external- and internal-rotation strength ratios for either the dominant or the nondominant shoulder. No significant differences were observed for external-rotation ROM, while internal-rotation ROM decreased moderately, in particular in the dominant shoulder (P = .005). Maximal throwing velocity remained constant for the dominant arm, whereas a significant increase was found for the nondominant arm (P = .017). This 6-wk strengthening program was effective in improving shoulder external-rotator muscle strength but resulted in a decrease in the ROM in shoulder internal rotation, while throwing velocity remained stable. Adding a stretching program to this type of sling-based training program might help avoid potential detrimental effects on shoulder ROM.

  17. Progress in geophysical aspects of the rotation of the earth

    NASA Technical Reports Server (NTRS)

    Lambeck, K.

    1978-01-01

    The geophysical causes and consequences of the Earth's rotation are reviewed. Specific topics covered include: (1) the motion of the rotation axis in space, precession and nutation; (2) the motion of the rotation axis relative to the Earth, polar motion; and (3) the rate of rotation about this axis, or changes in the length of day. Secular decrease in obliquity and evolution of the Earth-Moon system are also discussed.

  18. Changes in Pelvic Incidence, Pelvic Tilt, and Sacral Slope in Situations of Pelvic Rotation.

    PubMed

    Jin, Hai-Ming; Xu, Dao-Liang; Xuan, Jun; Chen, Jiao-Xiang; Chen, Kai; Goswami, Amit; Chen, Yu; Kong, Qiu-Yan; Wang, Xiang-Yang

    2017-08-01

    Digitally reconstructed radiograph-based study. Using a computer-based method to determine what degree of pelvic rotation is acceptable for measuring the pelvic incidence (PI), pelvic tilt (PT), and sacral slope (SS). The effectiveness of a geometrical formula used to calculate the angle of pelvic rotation proposed in a previous article was assessed. It is unclear whether PI, PT, and SS are valid with pelvic rotation while acquiring a radiograph. Ten 3-dimensionally reconstructed models were established with software and placed in a neutral orientation to orient all of the bones in a standing position. Next, 140 digitally reconstructed radiographs were obtained by rotating the models around the longitudinal axis of each pelvis in the software from 0 to 30 degrees at 2.5-degree intervals. PI, PT, and SS were measured. The rotation angle was considered to be acceptable when the change in the measured angle (compared with the "correct" position) was <6 degrees. The rotation angle (α) on the images was calculated by a geometrical formula. Consistency between the measured value and the set angle was assessed. The acceptable maximum angle of rotation for reliable measurements of PI was 17.5 degrees, and the changes in PT and SS were within an acceptable range (<6 degrees) when the pelvic rotation increased from 0 to 30 degrees. The effectiveness of the geometrical formula was shown by the consistency between the set and the calculated rotation angles of the pelvis (intraclass correlation coefficient=0.99). Our study provides insight into the influence of pelvic rotation on the PI, PT, and SS. PI changes with pelvic rotation. The acceptable maximum angle for reliable values of PI, PT, and SS was 17.5 degrees, and the rotation angle of the pelvis on a lateral spinopelvic radiograph can be calculated reliably.

  19. Economics, energy, and environmental assessment of diversified crop rotations in sub-Himalayas of India.

    PubMed

    Singh, Raman Jeet; Meena, Roshan Lal; Sharma, N K; Kumar, Suresh; Kumar, Kuldeep; Kumar, Dileep

    2016-02-01

    Reducing the carbon footprint and increasing energy use efficiency of crop rotations are the two most important sustainability issues of the modern agriculture. Present study was undertaken to assess economics, energy, and environmental parameters of common diversified crop rotations (maize-tomato, and maize-toria-wheat) vis-a-vis traditional crop rotations like maize-wheat, maize + ginger and rice-wheat of the north-western Himalayan region of India. Results revealed that maize-tomato and maize + ginger crop rotations being on par with each other produced significantly higher system productivity in terms of maize equivalent yield (30.2-36.2 t/ha) than other crop rotations (5.04-7.68 t/ha). But interestingly in terms of energy efficiencies, traditional maize-wheat system (energy efficiency 7.9, human energy profitability of 177.8 and energy profitability of 6.9 MJ/ha) was significantly superior over other systems. Maize + ginger rotation showed greater competitive advantage over other rotations because of less consumption of non-renewable energy resources. Similarly, maize-tomato rotation had ability of the production process to exploit natural resources due to 14-38% less use of commercial or purchased energy sources over other crop rotations. Vegetable-based crop rotations (maize + ginger and maize-tomato) maintained significantly the least carbon footprint (0.008 and 0.019 kg CO2 eq./kg grain, respectively) and the highest profitability (154,322 and 274,161 Rs./ha net return, respectively) over other crop rotations. As the greatest inputs of energy and carbon across the five crop rotations were nitrogen fertilizer (15-29% and 17-28%, respectively), diesel (14-24% and 8-19%, respectively) and irrigation (10-27% and 11-44%, respectively), therefore, alternative sources like organic farming, conservation agriculture practices, soil and water conservation measures, rain water harvesting etc. should be encouraged to reduce dependency of direct energy and external carbon inputs particularly in sub-Himalayas of India.

  20. Paleomagnetic evidence from land-based and ODP cores for clockwise rotation and northward translation of the Phillippine Sea plate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cisowski, S.M.; Fuller, M.; Haston, R.B.

    1990-06-01

    On-land and deep-sea core paleomagnetic data have been collected from around the Philippine Sea plate. Data from the Palau islands suggest 70{degree} of clockwise rotation and northward translation since the mid-Oligocene. The authors interpret this rotation as a rotation of the West Philippine Sea basin as a whole. New paleomagnetic data from Guam indicate 70{degree} of clockwise rotation and northward translation since the early Oligocene. Although Eocene results have been previously quoted, the new data suggest that there is no reliable Eocene data from Guam. New data from Saipan suggest 50-60{degree} of clockwise rotation since the Late Eocene and 20{degree}more » of clockwise rotation since the mid-Miocene, along with northward translation. During ODP Leg 126, a new technique utilizing the formation microscanner logging tool was employed to obtain orientated drill cores from the Bonin forearc basin. Preliminary results indicate that 70-110{degree} of clockwise rotation has occurred there since the mid-Oligocene. Inclination studies on cores from ODP Legs 125 and 126 along with the on-land paleomagnetic data support 15{degree} of northward translation of the Philippine Sea plate since the mid-Oligocene. The consistent clockwise rotations found around the Philippine Sea plate suggest that the entire plate, including the Bonin and Mariana arcs, has rotated more than 50{degree} since the mid-Oligocene. The similarity of Oligocene results from the Bonin forearc and Guam suggest that little or no relative rotation has occurred between these two points. This implies that the shape of the Mariana arc is probably not due to rotational deformation. The northward translation and clockwise rotation of the Philippine Sea plate established oblique subduction along the proto-Philippine margin, which could account for the 600 km of subducted slab beneath the eastern Celebes Sea.« less

  1. In situ forces and length patterns of the fibular collateral ligament under controlled loading: an in vitro biomechanical study using a robotic system.

    PubMed

    Liu, Ping; Wang, Jianquan; Xu, Yan; Ao, Yingfang

    2015-04-01

    The aim of this study was to determine the in situ forces and length patterns of the fibular collateral ligament (FCL) and kinematics of the knee under various loading conditions. Six fresh-frozen cadaveric knees were used (mean age 46 ± 14.4 years; range 20-58). In situ forces and length patterns of FCL and kinematics of the knee were determined under the following loading conditions using a robotic/universal force-moment sensor testing system: no rotation, varus (10 Nm), external rotation (5 Nm), and internal rotation (5 Nm) at 0°, 15°, 30°, 60º, 90°, and 120° of flexion, respectively. Under no rotation loading, the distances between the centres of the FCL attachments decreased as the knee flexed. Under varus loading, the force in FCL peaked at 15° of flexion and decreased with further knee flexion, while distances remained nearly constant and the varus rotation increased with knee flexion. Using external rotation, the force in the FCL also peaked at 15° flexion and decreased with further knee flexion, the distances decreased with flexion, and external rotation increased with knee flexion. Using internal rotation load, the force in the FCL was relatively small across all knee flexion angles, and the distances decreased with flexion; the amount of internal rotation was fairly constant. FCL has a primary role in preventing varus and external rotation at 15° of flexion. The FCL does not perform isometrically following knee flexion during neutral rotation, and tibia rotation has significant effects on the kinematics of the FCL. Varus and external rotation laxity increased following knee flexion. By providing more realistic data about the function and length patterns of the FCL and the kinematics of the intact knee, improved reconstruction and rehabilitation protocols can be developed.

  2. Grading apical vertebral rotation without a computed tomography scan: a clinically relevant system based on the radiographic appearance of bilateral pedicle screws.

    PubMed

    Upasani, Vidyadhar V; Chambers, Reid C; Dalal, Ali H; Shah, Suken A; Lehman, Ronald A; Newton, Peter O

    2009-08-01

    Bench-top and retrospective analysis to assess vertebral rotation based on the appearance of bilateral pedicle screws in patients with adolescent idiopathic scoliosis (AIS). To develop a clinically relevant radiographic grading system for evaluating postoperative thoracic apical vertebral rotation that would correlate with computed tomography (CT) measures of rotation. The 3-column vertebral body control provided by bilateral pedicle screws has enabled scoliosis surgeons to develop advanced techniques of direct vertebral derotation. Our ability to accurately quantify spinal deformity in the axial plane, however, continues to be limited. Trigonometry was used to define the relationship between the position of bilateral pedicle screws and vertebral rotation. This relationship was validated using digital photographs of a bench-top model. The mathematical relationships were then used to calculate vertebral rotation from standing postoperative, posteroanterior radiographs in AIS patients and correlated with postoperative CT measures of rotation. Fourteen digital photographs of the bench-top model were independently analyzed twice by 3 coauthors. The mathematically calculated degree of rotation was found to correlate significantly with the actual degree of rotation (r = 0.99; P < 0.001) and the intra- and interobserver reliability for these measurements were both excellent (kappa = 0.98 and kappa = 0.97, respectively). In the retrospective analysis of 17 AIS patients, the average absolute difference between the radiographic measurement of rotation and the CT measure was only 1.9 degrees +/- 2.0 degrees (r = 0.92; P < 0.001). Based on these correlations a simple radiographic grading system for postoperative apical vertebral rotation was developed. An accurate assessment of vertebral rotation can be performed radiographically, using screw lengths and screw tip-to-rod distances of bilateral segmental pedicle screws and a trigonometric calculation. These data support the use of a simple radiographic grading system to approximate apical vertebral rotation in AIS patients treated with bilateral apical pedicle screws.

  3. Counterclockwise and Clockwise Rotation of QRS Transitional Zone: Prospective Correlates of Change and Time-Varying Associations With Cardiovascular Outcomes.

    PubMed

    Patel, Siddharth; Kwak, Lucia; Agarwal, Sunil K; Tereshchenko, Larisa G; Coresh, Josef; Soliman, Elsayed Z; Matsushita, Kunihiro

    2017-11-03

    A few studies have recently reported clockwise and counterclockwise rotations of QRS transition zone as predictors of mortality. However, their prospective correlates and associations with individual cardiovascular disease (CVD) outcomes are yet to be investigated. Among 13 567 ARIC (Atherosclerosis Risk in Communities) study participants aged 45 to 64 years, we studied key correlates of changes in the status of clockwise and counterclockwise rotation over time as well as the association of rotation status with incidence of coronary heart disease (2408 events), heart failure (2196 events), stroke (991 events), composite CVD (4124 events), 898 CVD deaths, and 3469 non-CVD deaths over 23 years of follow-up. At baseline, counterclockwise rotation was most prevalent (52.9%), followed by no (40.5%) and clockwise (6.6%) rotation. Of patients with no rotation, 57.9% experienced counterclockwise or clockwise rotation during follow-up, with diabetes mellitus and black race significantly predicting clockwise and counterclockwise conversion, respectively. Clockwise rotation was significantly associated with higher risk of heart failure (hazard ratio, 1.20; 95% confidence interval [CI], 1.02-1.41) and non-CVD death (hazard ratio, 1.28; 95% CI, 1.12-1.46) after adjusting for potential confounders including other ECG parameters. On the contrary, counterclockwise rotation was significantly related to lower risk of composite CVD (hazard ratio, 0.93; 95% CI, 0.87-0.99]), CVD mortality (hazard ratio, 0.76; 95% CI, 0.65-0.88), and non-CVD deaths (hazard ratio, 0.92; 95% CI, 0.85-0.99 [borderline significance with heart failure]). Counterclockwise rotation, the most prevalent QRS transition zone pattern, demonstrated the lowest risk of CVD and mortality, whereas clockwise rotation was associated with the highest risk of heart failure and non-CVD mortality. These results have implications on how to interpret QRS transition zone rotation when ECG was recorded. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  4. Cost-Effectiveness of Reverse Total Shoulder Arthroplasty Versus Arthroscopic Rotator Cuff Repair for Symptomatic Large and Massive Rotator Cuff Tears.

    PubMed

    Makhni, Eric C; Swart, Eric; Steinhaus, Michael E; Mather, Richard C; Levine, William N; Bach, Bernard R; Romeo, Anthony A; Verma, Nikhil N

    2016-09-01

    To compare the cost-effectiveness within the United States health care system of arthroscopic rotator cuff repair versus reverse total shoulder arthroplasty in patients with symptomatic large and massive rotator cuff tears without cuff-tear arthropathy. An expected-value decision analysis was constructed comparing the costs and outcomes of patients undergoing arthroscopic rotator cuff repair and reverse total shoulder arthroplasty for large and massive rotator cuff tears (and excluding cases of cuff-tear arthropathy). Comprehensive literature search provided input data to extrapolate costs and health utility states for these outcomes. The primary outcome assessed was that of incremental cost-effectiveness ratio (ICER) of reverse total shoulder arthroplasty versus rotator cuff repair. For the base case, both arthroscopic rotator cuff repair and reverse total shoulder were superior to nonoperative care, with an ICER of $15,500/quality-adjusted life year (QALY) and $37,400/QALY, respectively. Arthroscopic rotator cuff repair was dominant over primary reverse total shoulder arthroplasty, with lower costs and slightly improved clinical outcomes. Arthroscopic rotator cuff repair was the preferred strategy as long as the lifetime progression rate from retear to end-stage cuff-tear arthropathy was less than 89%. However, when the model was modified to account for worse outcomes when reverse shoulder arthroplasty was performed after a failed attempted rotator cuff repair, primary reverse total shoulder had superior outcomes with an ICER of $90,000/QALY. Arthroscopic rotator cuff repair-despite high rates of tendon retearing-for patients with large and massive rotator cuff tears may be a more cost-effective initial treatment strategy when compared with primary reverse total shoulder arthroplasty and when assuming no detrimental impact of previous surgery on outcomes after arthroplasty. Clinical judgment should still be prioritized when formulating treatment plans for these patients. LEVEL OF EVIDENCE: Level II, economic decision analysis. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. CURRENT CONCEPTS ON THE GENETIC FACTORS IN ROTATOR CUFF PATHOLOGY AND FUTURE IMPLICATIONS FOR SPORTS PHYSICAL THERAPISTS

    PubMed Central

    Paré, Jessica; Froehlich, John E

    2017-01-01

    Context Recent advances within the field of genetics are currently changing many of the methodologies in which medicine is practiced. These advances are also beginning to influence the manner in which physical therapy services are rendered. Rotator cuff pathology is one of the most common diagnoses treated by the sports physical therapist. The purpose of this commentary is to educate sports physical therapists on the recent advances regarding how genetics influences rotator cuff pathology, including rotator cuff tears, and provide a perspective on how this information will likely influence post-operative shoulder rehabilitation in the near future. Evidence Acquisition A comprehensive review of the literature was completed using the Medline database along with individual searches of relevant physical therapy, surgical, cell biology, and sports medicine journals. Search terms included: shoulder, rotator cuff pathology, genetics, apoptosis, and physical therapy. Search results were compiled and evaluated; relevant primary studies and review articles were gathered; the results from this comprehensive review are summarized here. Study Design Clinical Commentary, Review of the Literature Results Recent advances within the understanding of rotator cuff pathology have further elucidated the cellular and molecular mechanisms associated with rotator cuff tears. There appears to be a hypoxic-induced apoptotic cellular pathway that contributes to rotator cuff tears. Activation of specific proteins termed matrix metalloproteinases appear to be involved in not only primary rotator cuff tears, but also may influence the re-tear rate after surgical intervention. Further advancements in the understanding of the cellular mechanisms contributing to rotator cuff tears and postoperative techniques to help prevent re-tears, may soon influence the methodology in which physical therapy services are provided to patients sustaining a rotator cuff injury. Conclusions At this time continued research is required to more fully develop a comprehensive understanding of the role of genetic variables both within primary rotator cuff tears and their influences on post-operative rehabilitation from rotator cuff repair surgery. Level of Evidence Level 5 PMID:28515982

  6. The Immediate Effects of Upper Thoracic Translatoric Spinal Manipulation on Cervical Pain and Range of Motion: A Randomized Clinical Trial

    PubMed Central

    Krauss, John; Creighton, Doug; Ely, Jonathan D.; Podlewska-Ely, Joanna

    2008-01-01

    This study examined the effect of translatoric spinal manipulation (TSM) on cervical pain and cervical active motion restriction when applied to upper thoracic (T1-T4) segments. Active cervical rotation range of motion was measured re- and post-intervention with a cervical inclinometer (CROM), and cervical pain status was monitored before and after manipulation with a Faces Pain Scale. Study participants included a sample of convenience that included 32 patients referred to physical therapy with complaints of pain in the mid-cervical region and restricted active cervical rotation. Twenty-two patients were randomly assigned to the experimental group and ten were assigned to the control group. Pre- and post-intervention cervical range of motion and pain scale measurements were taken by a physical therapist assistant who was blinded to group assignment. The experimental group received TSM to hypomobile upper thoracic segments. The control group received no intervention. Paired t-tests were used to analyze within-group changes in cervical rotation and pain, and a 2-way repeated-measure ANOVA was used to analyze between-group differences in cervical rotation and pain. Significance was accepted at p = 0.05. Significant changes that exceeded the MDC95 were detected for cervical rotation both within group and between groups with the TSM group demonstrating increased mean (SD) in right rotation of 8.23° (7.41°) and left rotation of 7.09° (5.83°). Pain levels perceived during post-intervention cervical rotation showed significant improvement during right rotation for patients experiencing pain during bilateral rotation only (p=.05). This study supports the hypothesis that spinal manipulation applied to the upper thoracic spine (T1-T4 motion segments) significantly increases cervical rotation ROM and may reduce cervical pain at end range rotation for patients experiencing pain during bilateral cervical rotation. PMID:19119394

  7. Dynamic Collimator Angle Adjustments During Volumetric Modulated Arc Therapy to Account for Prostate Rotations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boer, Johan de; Wolf, Anne Lisa; Szeto, Yenny Z.

    2015-04-01

    Purpose: Rotations of the prostate gland induce considerable geometric uncertainties in prostate cancer radiation therapy. Collimator and gantry angle adjustments can correct these rotations in intensity modulated radiation therapy. Modern volumetric modulated arc therapy (VMAT) treatments, however, include a wide range of beam orientations that differ in modulation, and corrections require dynamic collimator rotations. The aim of this study was to implement a rotation correction strategy for VMAT dose delivery and validate it for left-right prostate rotations. Methods and Materials: Clinical VMAT treatment plans of 5 prostate cancer patients were used. Simulated left-right prostate rotations between +15° and −15° weremore » corrected by collimator rotations. We compared corrected and uncorrected plans by dose volume histograms, minimum dose (D{sub min}) to the prostate, bladder surface receiving ≥78 Gy (S78) and rectum equivalent uniform dose (EUD; n=0.13). Each corrected plan was delivered to a phantom, and its deliverability was evaluated by γ-evaluation between planned and delivered dose, which was reconstructed from portal images acquired during delivery. Results: On average, clinical target volume minimum dose (D{sub min}) decreased up to 10% without corrections. Negative left-right rotations were corrected almost perfectly, whereas D{sub min} remained within 4% for positive rotations. Bladder S78 and rectum EUD of the corrected plans matched those of the original plans. The average pass rate for the corrected plans delivered to the phantom was 98.9% at 3% per 3 mm gamma criteria. The measured dose in the planning target volume approximated the original dose, rotated around the simulated left-right angle, well. Conclusions: It is feasible to dynamically adjust the collimator angle during VMAT treatment delivery to correct for prostate rotations. This technique can safely correct for left-right prostate rotations up to 15°.« less

  8. Yield and Economic Responses of Peanut to Crop Rotation Sequence

    USDA-ARS?s Scientific Manuscript database

    Proper crop rotation is essential to maintaining high peanut yield and quality. However, the economic considerations of maintaining or altering crop rotation sequences must incorporate the commodity prices, production costs, and yield responses of all crops in, or potentially in, the crop rotation ...

  9. 77 FR 71008 - Guidance for Industry: Enforcement Policy Concerning Rotational Warning Plans for Smokeless...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-28

    ...] Guidance for Industry: Enforcement Policy Concerning Rotational Warning Plans for Smokeless Tobacco... ``Enforcement Policy Concerning Rotational Warning Plans for Smokeless Tobacco Products,'' that was announced in... Concerning Rotational Warning Plans for Smokeless Tobacco Products.'' This guidance provided information to...

  10. A laboratory comparison of clockwise and counter-clockwise rapidly rotating shift schedules, part I, sleep : final report.

    DOT National Transportation Integrated Search

    2002-05-01

    INTRODUCTION. Many air traffic control specialists work relatively unique counter-clockwise, rapidly rotating shift schedules. Researchers recommend, however, that if rotating schedules are to be used, they should rotate in a clockwise, rather than a...

  11. Holographic flow visualization in rotating turbomachinery

    NASA Astrophysics Data System (ADS)

    Parker, R. J.; Reeves, M.

    1990-11-01

    Holographic flow visualization has found many applications in rotating turbomachinery. Applications in the design of aeroengine fans, automotive turbochargers, turbines, helicopter rotors, and advanced propfans are discussed. Work in ducted rotating flows and rotating free aerofoils is brought together and new developments in each field are revealed.

  12. THE EFFECT OF GRAVITATION ON THE POLARIZATION STATE OF A LIGHT RAY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghosh, Tanay; Sen, A. K.

    In the present work, detailed calculations have been carried out on the rotation of the polarization vector of an electromagnetic wave due to the presence of a gravitational field of a rotating body. This has been done using the general expression of Maxwell’s equation in curved spacetime. Considering the far-field approximation (i.e., the impact parameter is greater than the Schwarzschild radius and rotation parameter), the amount of rotation of the polarization vector as a function of impact parameter has been obtained for a rotating body (considering Kerr geometry). The present work shows that the rotation of the polarization vector cannotmore » be observed in the case of Schwarzschild geometry. This work also calculates the rotational effect when considering prograde and retrograde orbits for the light ray. Although the present work demonstrates the effect of rotation of the polarization vector, it confirms that there would be no net polarization of an electromagnetic wave due to the curved spacetime geometry in a Kerr field.« less

  13. Analytical Solution for the Anisotropic Rabi Model: Effects of Counter-Rotating Terms

    NASA Astrophysics Data System (ADS)

    Zhang, Guofeng; Zhu, Hanjie

    2015-03-01

    The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the numerical calculations in a wide range of the parameters including the ultrastrong coupling regime. In the weak counter-rotating coupling limit we find out that the counter-rotating terms can be considered as the shifts to the parameters of the Jaynes-Cummings model. This modification shows the validness of the rotating-wave approximation on the assumption of near-resonance and relatively weak coupling. Moreover, the analytical expressions of several physics quantities are also derived, and the results show the break-down of the U(1)-symmetry and the deviation from the Jaynes-Cummings model.

  14. Analytical solution for the anisotropic Rabi model: effects of counter-rotating terms.

    PubMed

    Zhang, Guofeng; Zhu, Hanjie

    2015-03-04

    The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the numerical calculations in a wide range of the parameters including the ultrastrong coupling regime. In the weak counter-rotating coupling limit we find out that the counter-rotating terms can be considered as the shifts to the parameters of the Jaynes-Cummings model. This modification shows the validness of the rotating-wave approximation on the assumption of near-resonance and relatively weak coupling. Moreover, the analytical expressions of several physics quantities are also derived, and the results show the break-down of the U(1)-symmetry and the deviation from the Jaynes-Cummings model.

  15. Viscoelastic flow in rotating curved pipes

    NASA Astrophysics Data System (ADS)

    Chen, Yitung; Chen, Huajun; Zhang, Jinsuo; Zhang, Benzhao

    2006-08-01

    Fully developed viscoelastic flows in rotating curved pipes with circular cross section are investigated theoretically and numerically employing the Oldroyd-B fluid model. Based on Dean's approximation, a perturbation solution up to the secondary order is obtained. The governing equations are also solved numerically by the finite volume method. The theoretical and numerical solutions agree with each other very well. The results indicate that the rotation, as well as the curvature and elasticity, plays an important role in affecting the friction factor, the secondary flow pattern and intensity. The co-rotation enhances effects of curvature and elasticity on the secondary flow. For the counter-rotation, there is a critical rotational number RΩ', which can make the effect of rotation counteract the effect of curvature and elasticity. Complicated flow behaviors are found at this value. For the relative creeping flow, RΩ' can be estimated according to the expression RΩ'=-4Weδ. Effects of curvature and elasticity at different rotational numbers on both relative creeping flow and inertial flow are also analyzed and discussed.

  16. Latissimus dorsi transfer to restore external rotation with reverse shoulder arthroplasty: a biomechanical study.

    PubMed

    Favre, Philippe; Loeb, Michael D; Helmy, Naeder; Gerber, Christian

    2008-01-01

    In patients with pseudoparesis of the shoulder resulting from irreparable rotator cuff tears, reverse shoulder arthroplasty (RSA) can restore active elevation, but external rotation remains less predictable. Latissimus dorsi transfer (LDT) has been shown to be effective in restoring external rotation in patients with posterosuperior tears of the rotator cuff. The aim of this study is to determine the capacity of the LDT to restore external rotation in combination with RSA and to investigate the mechanical advantage produced by 3 different insertion sites. A biomechanical model was created using a reverse total shoulder prosthesis with 3 different transfer insertions. Moment arms were measured for 2 static positions and 1 motion of the humerus. The moment arm analysis showed that LDT can improve active external rotation in the setting of a reverse prosthesis. An insertion site on the posterior side of the greater tuberosity (adjacent to the teres minor insertion) produced a greater external rotation moment arm.

  17. Universal relations for differentially rotating relativistic stars at the threshold to collapse

    NASA Astrophysics Data System (ADS)

    Bozzola, Gabriele; Stergioulas, Nikolaos; Bauswein, Andreas

    2018-03-01

    A binary neutron star merger produces a rapidly and differentially rotating compact remnant whose lifespan heavily affects the electromagnetic and gravitational emissions. Its stability depends on both the equation of state (EOS) and the rotation law and it is usually investigated through numerical simulations. Nevertheless, by means of a sufficient criterion for secular instability, equilibrium sequences can be used as a computational inexpensive way to estimate the onset of dynamical instability, which, in general, is close to the secular one. This method works well for uniform rotation and relies on the location of turning points: stellar models that are stationary points in a sequence of equilibrium solutions with constant rest mass or angular momentum. Here, we investigate differentially rotating models (using a large number of EOSs and different rotation laws) and find that several universal relations between properly scaled gravitational mass, rest mass and angular momentum of the turning-point models that are valid for uniform rotation are insensitive to the degree of differential rotation, to high accuracy.

  18. Radiation area monitor device and method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vencelj, Matjaz; Stowe, Ashley C.; Petrovic, Toni

    A radiation area monitor device/method, utilizing: a radiation sensor; a rotating radiation shield disposed about the radiation sensor, wherein the rotating radiation shield defines one or more ports that are transparent to radiation; and a processor operable for analyzing and storing a radiation fingerprint acquired by the radiation sensor as the rotating radiation shield is rotated about the radiation sensor. Optionally, the radiation sensor includes a gamma and/or neutron radiation sensor. The device/method selectively operates in: a first supervised mode during which a baseline radiation fingerprint is acquired by the radiation sensor as the rotating radiation shield is rotated aboutmore » the radiation sensor; and a second unsupervised mode during which a subsequent radiation fingerprint is acquired by the radiation sensor as the rotating radiation shield is rotated about the radiation sensor, wherein the subsequent radiation fingerprint is compared to the baseline radiation fingerprint and, if a predetermined difference threshold is exceeded, an alert is issued.« less

  19. Rotation of lathe-cut hydrogel lenses on the eye.

    PubMed

    Harris, M G; Harris, K L; Ruddell, D

    1976-01-01

    The rotation lathe-cut HydroCurveTM gel contact lens was measured on six eyes to evaluate the parameters that influence lens rotation and to determine if this lens could be used to correct astigmatism. Of the 72 observations made, 73.6% showed some lens rotation, and 33.4% of the sample rotated more than 5 degrees per 10 blinks. Of the observations in which rotation was noted, 88.7% were encyclorotation. These results are similar to those found for spin-cast hydrogel lenses. None of the lens parameters evaluated seemed to be related to lens rotation, whereas the eye parameters studied were. Lenses were more likely to rotate on eyes with smaller corneal diameters, smaller palpebral apertures, and corneal curvatures steeper than 4 3.00 DK (X2, N =72, p less than 0.05). Our findings indicate that some method of lens stabilization will be needed before lathe-cut hydrogel lenses can be used to effectively correct astigmatism.

  20. Analytical Solution for the Anisotropic Rabi Model: Effects of Counter-Rotating Terms

    PubMed Central

    Zhang, Guofeng; Zhu, Hanjie

    2015-01-01

    The anisotropic Rabi model, which was proposed recently, differs from the original Rabi model: the rotating and counter-rotating terms are governed by two different coupling constants. This feature allows us to vary the counter-rotating interaction independently and explore the effects of it on some quantum properties. In this paper, we eliminate the counter-rotating terms approximately and obtain the analytical energy spectrums and wavefunctions. These analytical results agree well with the numerical calculations in a wide range of the parameters including the ultrastrong coupling regime. In the weak counter-rotating coupling limit we find out that the counter-rotating terms can be considered as the shifts to the parameters of the Jaynes-Cummings model. This modification shows the validness of the rotating-wave approximation on the assumption of near-resonance and relatively weak coupling. Moreover, the analytical expressions of several physics quantities are also derived, and the results show the break-down of the U(1)-symmetry and the deviation from the Jaynes-Cummings model. PMID:25736827

  1. The effect of the long head of the biceps on glenohumeral kinematics.

    PubMed

    Youm, Thomas; ElAttrache, Neal S; Tibone, James E; McGarry, Michelle H; Lee, Thay Q

    2009-01-01

    The long head of the biceps has been described as a stabilizing force in the setting of glenohumeral instability. However, data are lacking on the effect of loading the long head of the biceps on glenohumeral kinematics. Six cadaveric shoulders were tested for glenohumeral rotational range of motion and translation using a custom shoulder testing system and the Microscribe 3DLX (Immersion, San Jose, CA). The path of glenohumeral articulation (PGA) was measured by calculating the humeral head center with respect to the glenoid articular surface at maximal internal rotation, 30 degrees, 60 degrees, 90 degrees, and maximal external rotation. Significant decreases in glenohumeral rotational range of motion and translation were found with 22-N biceps loading vs the unloaded group. With respect to the PGA, the humeral rotation center was shifted posterior with biceps loading at maximal internal rotation, 30 degrees, and 60 degrees of external rotation. Loading the long head of the biceps significantly affects glenohumeral rotational range of motion, translations, and kinematics.

  2. Reynolds-Stress and Triple-Product Models Applied to a Flow with Rotation and Curvature

    NASA Technical Reports Server (NTRS)

    Olsen, Michael E.

    2016-01-01

    Turbulence models, with increasing complexity, up to triple product terms, are applied to the flow in a rotating pipe. The rotating pipe is a challenging case for turbulence models as it contains significant rotational and curvature effects. The flow field starts with the classic fully developed pipe flow, with a stationary pipe wall. This well defined condition is then subjected to a section of pipe with a rotating wall. The rotating wall introduces a second velocity scale, and creates Reynolds shear stresses in the radial-circumferential and circumferential-axial planes. Furthermore, the wall rotation introduces a flow stabilization, and actually reduces the turbulent kinetic energy as the flow moves along the rotating wall section. It is shown in the present work that the Reynolds stress models are capable of predicting significant reduction in the turbulent kinetic energy, but triple product improves the predictions of the centerline turbulent kinetic energy, which is governed by convection, dissipation and transport terms, as the production terms vanish on the pipe axis.

  3. Review of the Usefulness of Various Rotational Seismometers with Laboratory Results of Fibre-Optic Ones Tested for Engineering Applications

    PubMed Central

    Jaroszewicz, Leszek R.; Kurzych, Anna; Krajewski, Zbigniew; Marć, Paweł; Kowalski, Jerzy K.; Bobra, Piotr; Zembaty, Zbigniew; Sakowicz, Bartosz; Jankowski, Robert

    2016-01-01

    Starting with descriptions of rotational seismology, areas of interest and historical field measurements, the fundamental requirements for rotational seismometers for seismological and engineering application are formulated. On the above basis, a review of all existing rotational seismometers is presented with a description of the principles of their operation as well as possibilities to fulfill formulated requirements. This review includes mechanical, acoustical, electrochemical and optical devices and shows that the last of these types are the most promising. It is shown that optical rotational seismometer based on the ring-laser gyroscope concept is the best for seismological applications, whereas systems based on fiber-optic gyroscopes demonstrate parameters which are also required for engineering applications. Laboratory results of the Fibre-Optic System for Rotational Events & Phenomena Monitoring using a small 1-D shaking table modified to generate rotational excitations are presented. The harmonic and time-history tests demonstrate its usefulness for recording rotational motions with rates up to 0.25 rad/s. PMID:27999299

  4. Competition of Faraday rotation and birefringence in femtosecond laser direct written waveguides in magneto-optical glass.

    PubMed

    Liu, Qiang; Gross, S; Dekker, P; Withford, M J; Steel, M J

    2014-11-17

    We consider the process of Faraday rotation in femtosecond laser direct-write waveguides. The birefringence commonly associated with such waveguides may be expected to impact the observable Faraday rotation. Here, we theoretically calculate and experimentally verify the competition between Faraday rotation and birefringence in two waveguides created by laser writing in a commercial magneto-optic glass. The magnetic field applied to induce Faraday rotation is nonuniform, and as a result, we find that the two effects can be clearly separated and used to accurately determine even weak birefringence. The birefringence in the waveguides was determined to be on the scale of Δn = 10(-6) to 10(-5). The reduction in Faraday rotation caused by birefringence of order Δn = 10(-6) was moderate and we obtained approximately 9° rotation in an 11 mm waveguide. In contrast, for birefringence of order 10(-5), a significant reduction in the polarization azimuth change was found and only 6° rotation was observed.

  5. Influence of glenoid component design and humeral component retroversion on internal and external rotation in reverse shoulder arthroplasty: a cadaver study.

    PubMed

    Berhouet, J; Garaud, P; Favard, L

    2013-12-01

    A common disadvantage of reverse shoulder arthroplasty is limitation of the range of arm rotation. Several changes to the prosthesis design and implantation technique have been suggested to improve rotation range of motion (ROM). Glenoid component design and degree of humeral component retroversion influence rotation ROM after reverse shoulder arthroplasty. The Aequalis Reversed™ shoulder prosthesis (Tornier Inc., Edina, MN, USA) was implanted into 40 cadaver shoulders. Eight glenoid component combinations were tested, five with the 36-mm sphere (centred seating, eccentric seating, inferior tilt, centred with a 5-mm thick lateralised spacer, and centred with a 7-mm thick lateralised spacer) and three with the 42-mm sphere (centred with no spacer or with a 7-mm or 10-mm spacer). Humeral component position was evaluated with 0°, 10°, 20°, 30°, and 40° of retroversion. External and internal rotation ROMs to posterior and anterior impingement on the scapular neck were measured with the arm in 20° of abduction. The large glenosphere (42 mm) was associated with significantly (P<0.05) greater rotation ROMs, particularly when combined with a lateralised spacer (46° internal and 66° external rotation). Rotation ROMs were smallest with the 36-mm sphere. Greater humeral component retroversion was associated with a decrease in internal rotation and a significant increase (P<0.05) in external rotation. The best balance between rotation ROMs was obtained with the native retroversion, which was estimated at 17.5° on average in this study. Our anatomic study in a large number of cadavers involved a detailed and reproducible experimental protocol. However, we did not evaluate the variability in scapular anatomy. Earlier studies of the influence of technical parameters did not take humeral component retroversion into account. In addition, no previous studies assessed rotation ROMs. Rotation ROM should be improved by the use of a large-diameter glenosphere with a spacer to lateralise the centre of rotation of the gleno-humeral joint, as well as by positioning the humeral component at the patient's native retroversion value. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  6. Effects of Crossed Brassiere Straps on Pain, Range of Motion, and Electromyographic Activity of Scapular Upward Rotators in Women With Scapular Downward Rotation Syndrome.

    PubMed

    Kang, Min-Hyeok; Choi, Ji-Young; Oh, Jae-seop

    2015-12-01

    Scapular downward rotation syndrome manifests as an abnormally downward-rotated scapula at rest or with arm motion and typically results in neck and shoulder pain. The brassiere strap has been suggested as a possible contributing factor to scapula downward rotation and pain in the upper trapezius because of increased downward rotational force on the lateral aspect of the scapula. No study, however, has examined the influences of a modified brassiere strap on pain in and the function of the scapular muscles. To examine the effects of crossed brassiere straps on the pressure pain threshold (PPT) of the upper trapezius, neck rotation range of motion (ROM), and electromyographic activity of the scapular upward rotators in females with scapular downward rotation syndrome. Cross-over design. Laboratory. In total, 15 female subjects with scapular downward rotation syndrome were recruited at hospitals and a local university. All participants performed neck rotation and humeral elevation under 2 different conditions: parallel and crossed brassiere straps. The PPT of the upper trapezius was measured using an analog algometer, whereas neck rotation ROM was quantified with a 3-dimensional ultrasonic motion analysis system. The electromyographic activities of the upper trapezius, serratus anterior, and lower trapezius during humeral elevation were assessed with a surface electromyography system. Outcome measures were assessed under parallel and crossed brassiere strap conditions, and differences in outcomes between the conditions were analyzed using a paired t-test. The PPT and neck rotation ROM were increased when the subject was wearing the brassiere with crossed versus parallel straps (P < .001). Greater electromyographic activities of the serratus anterior, lower trapezius, and lesser upper trapezius muscles during humeral elevation were found under the crossed strap condition than the parallel strap condition (P < .05). These findings provide useful information for clinicians when designing management programs to decrease pain and improve biomechanical function for females with scapular downward rotation syndrome. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  7. Orthopaedic Surgery Residency: Perspectives of Applicants and Program Directors on Medical Student Away Rotations.

    PubMed

    O'Donnell, Seth W; Drolet, Brian C; Brower, Jonathan P; LaPorte, Dawn; Eberson, Craig P

    2017-01-01

    Senior medical students frequently rotate at orthopaedic residency programs away from their home medical schools. However, to our knowledge, the perspective of program directors (PDs) and applicants on the value, objectives, and costs of these rotations has not been studied. Surveys evaluating the frequency, costs, benefits, and objectives of away rotations were distributed to all orthopaedic residency PDs in the United States and applicants in the 2014-2015 Match cycle. Data analysis was conducted to perform inferential and descriptive statistics; comparisons were made between and among PD and applicant groups using two-tailed means Student t-test and analysis of variance. A total of 74 PD (46.0%) and 524 applicant (49.3%) responses were obtained from a national distribution. Applicants completed an average of 2.4 away rotations, with an average cost of $2,799. When stratified on self-reported likelihood of Matching, there were no substantial differences in the total number of rotations performed. The only marked differences between these groups were the United States Medical Licensing Examination Step 1 score and the number of applications to residency programs. PDs reported that significantly fewer rotations should be allowed, whereas applicants suggested higher limits (2.42 rotations versus 6.24, P < 0.001). PDs and applicants had similar perspectives on the value of away rotations; both groups reported more value in finding a "good fit" and making a good impression at the program and placed less value on the educational impact. The value of orthopaedic away rotations appears more utilitarian than educational for both PDs and applicants. Rotations are performed regardless of perceived likelihood of Matching and are used by students and programs to identify a "good fit." Therefore, given the portion of an academic year that is spent on orthopaedic rotations, findings showing perceived low educational value and marked discrepancies between the expected number of rotations by PDs and applicants indicate that the current structure of away rotations may not be well aligned with the mission of undergraduate medical education. V.

  8. SU-E-P-12: Pinnacle-Based Tool to Evaluate the Effect of Prostate Rotation as Determined by Calypso

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narayanan, S; Velasco-Schmitz, R; Claeys, K

    Purpose: When the Calypso reports a large prostate rotation and one does not have the means to make corrections, it is helpful to quantify its dosimetric effects. We have devised a simple scheme to achieve this in Pinnacle TPS. If it is determined that the PTV margin is inadequate, an alternate larger-margin plan may be adapted for the day. Methods: A three-step process using the Pinnacle Image fusion module was formulated to analyze the clinical effect of prostate rotation. The process includes (1) translating the image set such that the rotational axis is about the isocenter, (2) performing 3D rotationsmore » of the structures of interest, and (3) restoring the coordinates associated with the plan. The rotated structures are imported and overlayed on the original plan for evaluation. The tool was applied to three prostate cancer patients with relatively large rotations (95 fractions total). Prostate rotations are primarily due to variations in bladder and rectal filling, which may also affect the seminal vesicles. It is difficult to estimate the perturbation of seminal vesicles for a given prostate rotation. Therefore, the Calypso-derived rotation matrix was applied only to CTV and PTV (CTV+5mm). Results: The rotations were predominantly in the pitch direction with an absolute value ranging from 0–29 degrees (Median = 10°, Average = 14.5°). For various magnitudes of rotation, the CTV V100 decreased from the original 100% to 99.6%/99%/95% for 10°/15°/29° rotations, respectively. Likewise, the PTV V100 diminished from 95% to 92%/89%/82%. Conclusion: A tool, consisting only of features within a TPS, was used to evaluate the dosimetric effect of prostate rotation. Our study shows that under large uncorrected rotations, the tumor coverage is degraded and may require intervention in the form of plan adaptation. To this end, alternate plans with variable margins can be generated in advance for daily adaption.« less

  9. MOJAVE: MONITORING OF JETS IN ACTIVE GALACTIC NUCLEI WITH VLBA EXPERIMENTS. VIII. FARADAY ROTATION IN PARSEC-SCALE AGN JETS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hovatta, Talvikki; Lister, Matthew L.; Aller, Margo F.

    2012-10-01

    We report observations of Faraday rotation measures for a sample of 191 extragalactic radio jets observed within the MOJAVE program. Multifrequency Very Long Baseline Array observations were carried out over 12 epochs in 2006 at four frequencies between 8 and 15 GHz. We detect parsec-scale Faraday rotation measures in 149 sources and find the quasars to have larger rotation measures on average than BL Lac objects. The median core rotation measures are significantly higher than in the jet components. This is especially true for quasars where we detect a significant negative correlation between the magnitude of the rotation measure andmore » the de-projected distance from the core. We perform detailed simulations of the observational errors of total intensity, polarization, and Faraday rotation, and concentrate on the errors of transverse Faraday rotation measure gradients in unresolved jets. Our simulations show that the finite image restoring beam size has a significant effect on the observed rotation measure gradients, and spurious gradients can occur due to noise in the data if the jet is less than two beams wide in polarization. We detect significant transverse rotation measure gradients in four sources (0923+392, 1226+023, 2230+114, and 2251+158). In 1226+023 the rotation measure is for the first time seen to change sign from positive to negative over the transverse cuts, which supports the presence of a helical magnetic field in the jet. In this source we also detect variations in the jet rotation measure over a timescale of three months, which are difficult to explain with external Faraday screens and suggest internal Faraday rotation. By comparing fractional polarization changes in jet components between the four frequency bands to depolarization models, we find that an external purely random Faraday screen viewed through only a few lines of sight can explain most of our polarization observations, but in some sources, such as 1226+023 and 2251+158, internal Faraday rotation is needed.« less

  10. Maternal and neonatal morbidity in relation to the instrument used for mid-cavity rotational operative vaginal delivery: a prospective cohort study.

    PubMed

    Bahl, R; Van de Venne, M; Macleod, M; Strachan, B; Murphy, D J

    2013-11-01

    To compare the maternal and neonatal morbidity associated with alternative instruments used to perform a mid-cavity rotational delivery. A prospective cohort study. Two university teaching hospitals in Scotland and England. Three hundred and eighty-one nulliparous women who had a mid-cavity rotational operative vaginal delivery. A data collection sheet was completed by the research team following delivery. Postpartum haemorrhage, third- and fourth-degree perineal tears, low cord pH, neonatal trauma, and failed or sequential operative vaginal delivery. One hundred and sixty-three women (42.8%) underwent manual rotation followed by non-rotational forceps delivery, 73 (19.1%) had a rotational vacuum delivery, and 145 (38.1%) delivered with the assistance of rotational (Kielland) forceps. The rates of postpartum haemorrhage were similar when comparing manual rotation with rotational vacuum (adjusted OR 1.42, 95% CI 0.66-3.98), and when comparing manual rotation with Kielland forceps (adjusted OR 1.22, 95% CI 0.71-2.88). The results were comparable for third- and fourth-degree perineal tears (adjusted OR 0.85, 95% CI 0.13-1.89; adjusted OR 0.94, 95% CI 0.39-1.82), low cord pH (adjusted OR 1.76, 95% CI 0.44-6.91; adjusted OR 1.12, 95% CI 0.44-2.83), neonatal trauma (adjusted OR 0.50, 95% CI 0.16-1.55; adjusted OR 3.25, 95% CI 0.65-16.17), and admission to the neonatal intensive care unit (adjusted OR 1.47, 95% CI 0.45-4.81; adjusted OR 1.04, 95% CI 0.49-2.19). The sequential use of instruments was less likely with manual rotation and forceps than with rotational vacuum delivery (0.6 versus 36.9%, OR 0.01, 95% CI 0.002-0.090). Maternal and perinatal outcomes are comparable with Kielland forceps, vacuum extraction, and manual rotation, with few serious adverse outcomes. With appropriate training mid-cavity rotational delivery can be practiced safely, including the use of Kielland forceps. © 2013 RCOG.

  11. Sex differences in mental rotation with polygons of different complexity: Do men utilize holistic processes whereas women prefer piecemeal ones?

    PubMed

    Heil, Martin; Jansen-Osmann, Petra

    2008-05-01

    Sex differences in mental rotation were investigated as a function of stimulus complexity with a sample size of N = 72. Replicating earlier findings with polygons, mental rotation was faster for males than for females, and reaction time increased with more complex polygons. Additionally, sex differences increased for complex polygons. Most importantly, however, mental rotation speed decreased with increasing complexity for women but did not change for men. Thus, the sex effects reflect a difference in strategy, with women mentally rotating the polygons in an analytic, piecemeal fashion and men using a holistic mode of mental rotation.

  12. The Dissipation Rate Transport Equation and Subgrid-Scale Models in Rotating Turbulence

    NASA Technical Reports Server (NTRS)

    Rubinstein, Robert; Ye, Zhou

    1997-01-01

    The dissipation rate transport equation remains the most uncertain part of turbulence modeling. The difficulties arc increased when external agencies like rotation prevent straightforward dimensional analysis from determining the correct form of the modelled equation. In this work, the dissipation rate transport equation and subgrid scale models for rotating turbulence are derived from an analytical statistical theory of rotating turbulence. In the strong rotation limit, the theory predicts a turbulent steady state in which the inertial range energy spectrum scales as k(sup -2) and the turbulent time scale is the inverse rotation rate. This scaling has been derived previously by heuristic arguments.

  13. Homopolar motor with dual rotors

    DOEpatents

    Hsu, John S.

    1998-01-01

    A homopolar motor (10) has a field rotor (15) mounted on a frame (11) for rotation in a first rotational direction and for producing an electromagnetic field, and an armature rotor (17) mounted for rotation on said frame (11) within said electromagnetic field and in a second rotational direction counter to said first rotational direction of said field rotor (15). The two rotors (15, 17) are coupled through a 1:1 gearing mechanism (19), so as to travel at the same speed but in opposite directions. This doubles the output voltage and output power, as compared to a motor in which only the armature is rotated. Several embodiments are disclosed.

  14. Orthotic arm joint. [for use in mechanical arms

    NASA Technical Reports Server (NTRS)

    Dane, D. H. (Inventor)

    1974-01-01

    An improved orthopedic (orthotic) arm joint that can be used in various joint of mechanical arms is described. The arm joints includes a worm, which is coupled to an electric motor for rotating a worm gear carried within a rotatable housing. The worm gear is supported on a thrust bearing and the rotatable housing is supported on a radial thrust bearing. A bolt extends through the housing, bearings, and worm gear for securing the device together. A potentiometer extends through the bolt, and is coupled to the rotatable housing for rotating therewith, so as to produce an electrical signal indicating the angular position of the rotatable housing.

  15. Resonance rotational level crossing in the fluorosulfate radical FSO3rad and experimental determination of the rotational A and the centrifugal distortion DK constants

    NASA Astrophysics Data System (ADS)

    Kolesniková, Lucie; Koucký, Jan; Kania, Patrik; Uhlíková, Tereza; Beckers, Helmut; Urban, Štěpán

    2018-01-01

    The resonance crossing of rotational levels with different fine-structure components and different k rotational quantum numbers was observed in the rotational spectra of the symmetric top fluorosulfate radical FSO3rad. Detailed measurements were performed to analyze these weak resonances as well as the A1-A2 splittings of the K = 3 and K = 6 transitions. The resonance level crossing enabled the experimental determination of "forbidden" parameters, the rotational A and the centrifugal distortion DK constants as well as the corresponding resonance off-diagonal matrix element.

  16. Video- Demonstrations of Stable and Unstable Solid Body Rotation on the International Space Station

    NASA Technical Reports Server (NTRS)

    2003-01-01

    Saturday Morning Science, the science of opportunity series of applied experiments and demonstrations, performed aboard the International Space Station (ISS) by Expedition 6 astronaut Dr. Don Pettit, revealed some remarkable findings. In this video clip, Pettit demonstrates stable and unstable modes for solid body rotation on the ISS. Using a hard cover textbook, he demonstrates that it will rotate stably about the longest and shortest axis, which represent the maximum and minimum movements of Inertia. Trying to rotate the book around an intermediate axis results in an unstable rotation in which the book appears to flip-flop while it rotates.

  17. Tracking single-particle rotation during macrophage uptake

    DOE PAGES

    Sanchez, Lucero; Patton, Paul; Anthony, Stephen Michael; ...

    2015-06-10

    We investigated the rotational dynamics of single microparticles during their internalization by macrophage cells. The microparticles used were triblock patchy particles that display two fluorescent patches on their two poles. The optical anisotropy made it possible to directly visualize and quantify the orientation and rotation of the particles. We show that particles exhibit a mixture of fast and slow rotation as they are uptaken by macrophages and transiently undergo directional rotation during their entry into the cell. As a result, the size of the particles and the surface presentation of ligands exerted a negligible influence on this heterogeneity of particlemore » rotation.« less

  18. Factors affecting rotator cuff healing.

    PubMed

    Mall, Nathan A; Tanaka, Miho J; Choi, Luke S; Paletta, George A

    2014-05-07

    Several studies have noted that increasing age is a significant factor for diminished rotator cuff healing, while biomechanical studies have suggested the reason for this may be an inferior healing environment in older patients. Larger tears and fatty infiltration or atrophy negatively affect rotator cuff healing. Arthroscopic rotator cuff repair, double-row repairs, performing a concomitant acromioplasty, and the use of platelet-rich plasma (PRP) do not demonstrate an improvement in structural healing over mini-open rotator cuff repairs, single-row repairs, not performing an acromioplasty, or not using PRP. There is conflicting evidence to support postoperative rehabilitation protocols using early motion over immobilization following rotator cuff repair.

  19. From the RSNA refresher courses: US of the rotator cuff: pitfalls, limitations, and artifacts.

    PubMed

    Rutten, Matthieu J C M; Jager, Gerrit J; Blickman, Johan G

    2006-01-01

    High-resolution ultrasonography (US) has gained increasing popularity as a diagnostic tool for assessment of the soft tissues in shoulder impingement syndrome. US is a powerful and accurate method for diagnosis of rotator cuff tears and other rotator cuff abnormalities, provided the examiner has a detailed knowledge of shoulder anatomy, uses a standardized examination technique, and has a thorough understanding of the potential pitfalls, limitations, and artifacts. False-positive sonographic findings of rotator cuff tears can be caused by the technique (anisotropy, transducer positioning, acoustic shadowing by the deltoid septum), by the anatomy (rotator cuff interval, supraspinatus-infraspinatus interface, musculotendinous junction, fibrocartilaginous insertion), or by disease (criteria for diagnosis of rotator cuff tears, tendon inhomogeneity, acoustic shadowing by scar tissue or calcification, rotator cuff thinning). False-negative sonographic findings of rotator cuff tears can be caused by the technique (transducer frequency, suboptimal focusing, imaging protocol, transducer handling), by the anatomy (nondiastasis of the ruptured tendon fibers, posttraumatic obscuration of landmarks), by disease (tendinosis, calcifications, synovial proliferation, granulation or scar tissue, bursal thickening, massive rotator cuff tears), or by patient factors (obesity, muscularity, limited shoulder motion). (c) RSNA, 2006.

  20. Rotation Reveals the Importance of Configural Cues in Handwritten Word Perception

    PubMed Central

    Barnhart, Anthony S.; Goldinger, Stephen D.

    2013-01-01

    A dramatic perceptual asymmetry occurs when handwritten words are rotated 90° in either direction. Those rotated in a direction consistent with their natural tilt (typically clockwise) become much more difficult to recognize, relative to those rotated in the opposite direction. In Experiment 1, we compared computer-printed and handwritten words, all equated for degrees of leftward and rightward tilt, and verified the phenomenon: The effect of rotation was far larger for cursive words, especially when rotated in a tilt-consistent direction. In Experiment 2, we replicated this pattern with all items presented in visual noise. In both experiments, word frequency effects were larger for computer-printed words and did not interact with rotation. The results suggest that handwritten word perception requires greater configural processing, relative to computer print, because handwritten letters are variable and ambiguous. When words are rotated, configural processing suffers, particularly when rotation exaggerates natural tilt. Our account is similar to theories of the “Thatcher Illusion,” wherein face inversion disrupts holistic processing. Together, the findings suggest that configural, word-level processing automatically increases when people read handwriting, as letter-level processing becomes less reliable. PMID:23589201

  1. Experimental study of icing accretion on a rotating conical spinner

    NASA Astrophysics Data System (ADS)

    Chen, Ningli; Ji, Honghu; Hu, Yaping; Wang, Jian; Cao, Guangzhou

    2015-12-01

    A reduced scale experiment has been conducted to investigate the icing accretion procedure on a rotating spinner of 60° cone angle. The experiment was carried out in a small scale ice wind tunnel with three different rotating speeds of the spinner. The experimental conditions were determined from the actual icing condition of the spinner of a turbofan engine by using the similarity theory, which considers the rotating effects. The ice thickness on the spinner was got from the image taken by the high speed camera, by image processing. The results of this investigation show that under the experimental condition, ice on the spinner's tip of three different rotating speeds are all glaze ice and about the same thick. However, on the downstream surface of the spinner, ice shape on the rotating spinner is different from that on the stationary spinner. It is uneven glaze ice on the stationary spinner while it is `particle ice' when the rotating speed is 8240 rpm and it is `needle ice' when the rotating speed is 15,200 rpm. The experiment also reveals that when the rotating speed is higher, the ice layer is thicker.

  2. Laboratory and field testing of commercial rotational seismometers

    USGS Publications Warehouse

    Nigbor, R.L.; Evans, J.R.; Hutt, C.R.

    2009-01-01

    There are a small number of commercially available sensors to measure rotational motion in the frequency and amplitude ranges appropriate for earthquake motions on the ground and in structures. However, the performance of these rotational seismometers has not been rigorously and independently tested and characterized for earthquake monitoring purposes as is done for translational strong- and weak-motion seismometers. Quantities such as sensitivity, frequency response, resolution, and linearity are needed for the understanding of recorded rotational data. To address this need, we, with assistance from colleagues in the United States and Taiwan, have been developing performance test methodologies and equipment for rotational seismometers. In this article the performance testing methodologies are applied to samples of a commonly used commercial rotational seismometer, the eentec model R-1. Several examples were obtained for various test sequences in 2006, 2007, and 2008. Performance testing of these sensors consisted of measuring: (1) sensitivity and frequency response; (2) clip level; (3) self noise and resolution; and (4) cross-axis sensitivity, both rotational and translational. These sensor-specific results will assist in understanding the performance envelope of the R-1 rotational seismometer, and the test methodologies can be applied to other rotational seismometers.

  3. Rotation Capacity of Bolted Flush End-Plate Stiffened Beam-to-Column Connection

    NASA Astrophysics Data System (ADS)

    Ostrowski, Krzysztof; Kozłowski, Aleksander

    2017-06-01

    One of the flexibility parameters of semi-rigid joints is rotation capacity. Plastic rotation capacity is especially important in plastic design of framed structures. Current design codes, including Eurocode 3, do not posses procedures enabling designers to obtain value of rotation capacity. In the paper the calculation procedure of the rotation capacity for stiffened bolted flush end-plate beam-to-column connections has been proposed. Theory of experiment design was applied with the use of Hartley's PS/DS-P:Ha3 plan. The analysis was performed with the use of finite element method (ANSYS), based on the numerical experiment plan. The determination of maximal rotation angle was carried out with the use of regression analysis. The main variables analyzed in parametric study were: pitch of the bolt "w" (120-180 mm), the distance between the bolt axis and the beam upper edge cg1 (50-90 mm) and the thickness of the end-plate tp (10-20 mm). Power function was proposed to describe available rotation capacity of the joint. Influence of the particular components on the rotation capacity was also investigated. In the paper a general procedure for determination of rotation capacity was proposed.

  4. Pre-registration house officer rotations incorporating general practice: does the order of rotation matter?

    PubMed

    Williams, C; Cantillon, P; Cochrane, M

    2001-06-01

    In relation to pre-registration house officer (PRHO) rotations incorporating general practice, previous research has recommended that where possible, no PRHO should undertake general practice as the first placement, because of the difficulties encountered. It was recognized that logistically, this could make such schemes almost unworkable. Within the context of a larger qualitative evaluation comparing how 24 PRHOs learned in hospital and general practice settings, the issue of rotation order was explored. In-depth semistructured interviews were conducted with the 12 PRHOs who were involved in general practice rotations. They were interviewed at the beginning and end of the PRHO year, and following their return to hospital work after the general practice placement. Each rotation order had both advantages and disadvantages, with no particular rotation order being obviously better or worse for the PRHOs involved. This small qualitative evaluation has highlighted a number of advantages and disadvantages specific to each rotation order, and makes some practical recommendations to help alleviate the problems encountered. It is important that future evaluations of similar schemes consider this issue, as there are conflicting reports about the significance of the rotation order.

  5. Characteristics and Clinical Outcomes in Overhead Sports Athletes after Rotator Cuff Repair

    PubMed Central

    Inui, Hiroaki; Ninomiya, Hiroki; Tanaka, Hiroshi; Nobuhara, Katsuya

    2017-01-01

    Rotator cuff tears in young overhead sports athletes are rare. The pathomechanism causing rotator cuff tears in young overhead athletes is different from that in aged patients. The purpose of this study was to investigate rotator cuff tear characteristics in young overhead sports athletes to reveal the pathomechanism causing these injuries. This study included 25 overhead sports athletes less than 30 years old with atraumatic rotator cuff tears necessitating repair. Rotator cuff tear characteristics were evaluated intraoperatively, including rotator cuff tear shape and injured rotator cuff tendon. Clinical outcome measures were assessed before surgery and at the final follow-up. In this study, 22 patients reported minimal to no shoulder pain and returned to sports without significant complaints at last follow-up. The isolated infraspinatus tendon was most often injured; the incidence rate of the tear at this site was 32% (8 cases). In the deceleration phase of overhead motion, the eccentric contraction force of the ISP (infraspinatus) tendon peaks and the increased load leads to injury at the ISP tendon. The pathomechanism of rotator cuff injuries in young overhead athletes might be not only internal or subacromial impingement, but also these mechanisms. PMID:28702502

  6. Investigation of intrinsic toroidal rotation scaling in KSTAR

    NASA Astrophysics Data System (ADS)

    Yoo, J. W.; Lee, S. G.; Ko, S. H.; Seol, J.; Lee, H. H.; Kim, J. H.

    2017-07-01

    The behaviors of an intrinsic toroidal rotation without any external momentum sources are investigated in KSTAR. In these experiments, pure ohmic discharges with a wide range of plasma parameters are carefully selected and analyzed to speculate an unrevealed origin of toroidal rotation excluding any unnecessary heating sources, magnetic perturbations, and strong magneto-hydrodynamic activities. The measured core toroidal rotation in KSTAR is mostly in the counter-current direction and its magnitude strongly depends on the ion temperature divided by plasma current (Ti/IP). Especially the core toroidal rotation in the steady-state is well fitted by Ti/IP scaling with a slope of ˜-23, and the possible explanation of the scaling is compared with various candidates. As a result, the calculated offset rotation could not explain the measured core toroidal rotation since KSTAR has an extremely low intrinsic error field. For the stability conditions for ion and electron turbulences, it is hard to determine a dominant turbulence mode in this study. In addition, the intrinsic toroidal rotation level in ITER is estimated based on the KSTAR scaling since the intrinsic rotation plays an important role in stabilizing resistive wall modes for future reference.

  7. Geometry of tracer trajectories in turbulent rotating convection

    NASA Astrophysics Data System (ADS)

    Alards, Kim; Rajaei, Hadi; Kunnen, Rudie; Toschi, Federico; Clercx, Herman

    2016-11-01

    In Rayleigh-Bénard convection rotation is known to cause transitions in flow structures and to change the level of anisotropy close to the horizontal plates. To analyze this effect of rotation, we collect curvature and torsion statistics of passive tracer trajectories in rotating Rayleigh-Bénard convection, using both experiments and direct numerical simulations. In previous studies, focusing on homogeneous isotropic turbulence (HIT), curvature and torsion PDFs are found to reveal pronounced power laws. In the center of the convection cell, where the flow is closest to HIT, we recover these power laws, regardless of the rotation rate. However, near the top plate, where we expect the flow to be anisotropic, the scaling of the PDFs deviates from the HIT prediction for lower rotation rates. This indicates that anisotropy clearly affects the geometry of tracer trajectories. Another effect of rotation is observed as a shift of curvature and torsion PDFs towards higher values. We expect this shift to be related to the length scale of typical flow structures. Using curvature and torsion statistics, we can characterize how these typical length scales evolve under rotation and moreover analyze the effect of rotation on more complicated flow characteristics, such as anisotropy.

  8. BREAKDOWN OF I-LOVE-Q UNIVERSALITY IN RAPIDLY ROTATING RELATIVISTIC STARS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doneva, Daniela D.; Yazadjiev, Stoytcho S.; Kokkotas, Kostas D.

    It was shown recently that normalized relations between the moment of inertia (I), the quadrupole moment (Q), and the tidal deformability (Love number) exist and for slowly rotating neutron stars they are almost independent of the equation of state (EOS). We extend the computation of the I-Q relation to models rotating up to the mass-shedding limit and show that the universality of the relations is lost. With increasing rotation rate, the normalized I-Q relation departs significantly from its slow-rotation limit, deviating up to 40% for neutron stars and up to 75% for strange stars. The deviation is also EOS dependentmore » and for a broad set of hadronic and strange matter EOSs the spread due to rotation is comparable to the spread due to the EOS, if one considers sequences with fixed rotational frequency. Still, for a restricted sample of modern realistic EOSs one can parameterize the deviations from universality as a function of rotation only. The previously proposed I-Love-Q relations should thus be used with care, because they lose their universality in astrophysical situations involving compact objects rotating faster than a few hundred Hz.« less

  9. Effect of preceding crop on Fusarium species and mycotoxin contamination of wheat grains.

    PubMed

    Qiu, Jianbo; Dong, Fei; Yu, Mingzheng; Xu, Jianhong; Shi, Jianrong

    2016-10-01

    The Fusarium graminearum species complex infects several cereals and causes the reduction of grain yield and quality. Many factors influence the extent of Fusarium infection and mycotoxin levels. Such factors include crop rotation. In the present study, we explored the effect of rice or maize as former crops on mycotoxin accumulation in wheat grains. More than 97% of samples were contaminated with deoxynivalenol (DON). DON concentrations in wheat grains from rice and maize rotation fields were 884.37 and 235.78 µg kg(-1) . Zearalenone (ZEN) was detected in 45% of samples which were mainly collected from maize-wheat rotation systems. Fusarium strains were isolated and more F. graminearum sensu stricto (s. str.) isolates were cultured from wheat samples obtained from maize rotation fields. DON levels produced by Fusarium isolates from rice rotation fields were higher than those of samples from maize rotation fields. Rice-wheat rotation favours DON accumulation, while more ZEN contamination may occur in maize-wheat rotation models. Appropriate crop rotation may help to reduce toxin levels in wheat grains. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  10. Investigation of the asymptotic state of rotating turbulence using large-eddy simulation

    NASA Technical Reports Server (NTRS)

    Squires, Kyle D.; Chasnov, Jeffrey R.; Mansour, Nagi N.; Cambon, Claude

    1993-01-01

    Study of turbulent flows in rotating reference frames has long been an area of considerable scientific and engineering interest. Because of its importance, the subject of turbulence in rotating reference frames has motivated over the years a large number of theoretical, experimental, and computational studies. The bulk of these previous works has served to demonstrate that the effect of system rotation on turbulence is subtle and remains exceedingly difficult to predict. A rotating flow of particular interest in many studies, including the present work, is examination of the effect of solid-body rotation on an initially isotropic turbulent flow. One of the principal reasons for the interest in this flow is that it represents the most basic turbulent flow whose structure is altered by system rotation but without the complicating effects introduced by mean strains or flow inhomogeneities. The assumption of statistical homogeneity considerably simplifies analysis and computation. The principal objective of the present study has been to examine the asymptotic state of solid-body rotation applied to an initially isotropic, high Reynolds number turbulent flow. Of particular interest has been to determine the degree of two-dimensionalization and the existence of asymptotic self-similar states in homogeneous rotating turbulence.

  11. Form features provide a cue to the angular velocity of rotating objects

    PubMed Central

    Blair, Christopher David; Goold, Jessica; Killebrew, Kyle; Caplovitz, Gideon Paul

    2013-01-01

    As an object rotates, each location on the object moves with an instantaneous linear velocity dependent upon its distance from the center of rotation, while the object as a whole rotates with a fixed angular velocity. Does the perceived rotational speed of an object correspond to its angular velocity, linear velocities, or some combination of the two? We had observers perform relative speed judgments of different sized objects, as changing the size of an object changes the linear velocity of each location on the object’s surface, while maintaining the object’s angular velocity. We found that the larger a given object is, the faster it is perceived to rotate. However, the observed relationships between size and perceived speed cannot be accounted for simply by size-related changes in linear velocity. Further, the degree to which size influences perceived rotational speed depends on the shape of the object. Specifically, perceived rotational speeds of objects with corners or regions of high contour curvature were less affected by size. The results suggest distinct contour features, such as corners or regions of high or discontinuous contour curvature, provide cues to the angular velocity of a rotating object. PMID:23750970

  12. Form features provide a cue to the angular velocity of rotating objects.

    PubMed

    Blair, Christopher David; Goold, Jessica; Killebrew, Kyle; Caplovitz, Gideon Paul

    2014-02-01

    As an object rotates, each location on the object moves with an instantaneous linear velocity, dependent upon its distance from the center of rotation, whereas the object as a whole rotates with a fixed angular velocity. Does the perceived rotational speed of an object correspond to its angular velocity, linear velocities, or some combination of the two? We had observers perform relative speed judgments of different-sized objects, as changing the size of an object changes the linear velocity of each location on the object's surface, while maintaining the object's angular velocity. We found that the larger a given object is, the faster it is perceived to rotate. However, the observed relationships between size and perceived speed cannot be accounted for simply by size-related changes in linear velocity. Further, the degree to which size influences perceived rotational speed depends on the shape of the object. Specifically, perceived rotational speeds of objects with corners or regions of high-contour curvature were less affected by size. The results suggest distinct contour features, such as corners or regions of high or discontinuous contour curvature, provide cues to the angular velocity of a rotating object. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  13. Temporal Variation of the Rotation of the Solar Mean Magnetic Field

    NASA Astrophysics Data System (ADS)

    Xie, J. L.; Shi, X. J.; Xu, J. C.

    2017-04-01

    Based on continuous wavelet transformation analysis, the daily solar mean magnetic field (SMMF) from 1975 May 16 to 2014 July 31 is analyzed to reveal its rotational behavior. Both the recurrent plot in Bartels form and the continuous wavelet transformation analysis show the existence of rotational modulation in the variation of the daily SMMF. The dependence of the rotational cycle lengths on solar cycle phase is also studied, which indicates that the yearly mean rotational cycle lengths generally seem to be longer during the rising phase of solar cycles and shorter during the declining phase. The mean rotational cycle length for the rising phase of all of the solar cycles in the considered time is 28.28 ± 0.67 days, while for the declining phase it is 27.32 ± 0.64 days. The difference of the mean rotational cycle lengths between the rising phase and the declining phase is 0.96 days. The periodicity analysis, through the use of an auto-correlation function, indicates that the rotational cycle lengths have a significant period of about 10.1 years. Furthermore, the cross-correlation analysis indicates that there exists a phase difference between the rotational cycle lengths and solar activity.

  14. Enhanced Stellar Activity for Slow Antisolar Differential Rotation?

    NASA Astrophysics Data System (ADS)

    Brandenburg, Axel; Giampapa, Mark S.

    2018-03-01

    High-precision photometry of solar-like members of the open cluster M67 with Kepler/K2 data has recently revealed enhanced activity for stars with a large Rossby number, which is the ratio of rotation period to the convective turnover time. Contrary to the well established behavior for shorter rotation periods and smaller Rossby numbers, the chromospheric activity of the more slowly rotating stars of M67 was found to increase with increasing Rossby number. Such behavior has never been reported before, although it was theoretically predicted to emerge as a consequence of antisolar differential rotation (DR) for stars with Rossby numbers larger than that of the Sun, because in those models the absolute value of the DR was found to exceed that for solar-like DR. Using gyrochronological relations and an approximate age of 4 Gyr for the members of M67, we compare with computed rotation rates using just the B ‑ V color. The resulting rotation–activity relation is found to be compatible with that obtained by employing the measured rotation rate. This provides additional support for the unconventional enhancement of activity at comparatively low rotation rates and the possible presence of antisolar differential rotation.

  15. Breakdown of I-Love-Q Universality in Rapidly Rotating Relativistic Stars

    NASA Astrophysics Data System (ADS)

    Doneva, Daniela D.; Yazadjiev, Stoytcho S.; Stergioulas, Nikolaos; Kokkotas, Kostas D.

    2014-01-01

    It was shown recently that normalized relations between the moment of inertia (I), the quadrupole moment (Q), and the tidal deformability (Love number) exist and for slowly rotating neutron stars they are almost independent of the equation of state (EOS). We extend the computation of the I-Q relation to models rotating up to the mass-shedding limit and show that the universality of the relations is lost. With increasing rotation rate, the normalized I-Q relation departs significantly from its slow-rotation limit, deviating up to 40% for neutron stars and up to 75% for strange stars. The deviation is also EOS dependent and for a broad set of hadronic and strange matter EOSs the spread due to rotation is comparable to the spread due to the EOS, if one considers sequences with fixed rotational frequency. Still, for a restricted sample of modern realistic EOSs one can parameterize the deviations from universality as a function of rotation only. The previously proposed I-Love-Q relations should thus be used with care, because they lose their universality in astrophysical situations involving compact objects rotating faster than a few hundred Hz.

  16. A Parametric Study of Erupting Flux Rope Rotation: Modeling the 'Cartwheel CME' on 9 April 2008

    NASA Technical Reports Server (NTRS)

    Kliem, B.; Toeroek, T.; Thompson, W. T.

    2012-01-01

    The rotation of erupting filaments in the solar corona is addressed through a parametric simulation study of unstable, rotating flux ropes in bipolar force-free initial equilibrium. The Lorentz force due to the external shear-field component and the relaxation of tension in the twisted field are the major contributors to the rotation in this model, while reconnection with the ambient field is of minor importance, due to the field's simple structure. In the low-beta corona, the rotation is not guided by the changing orientation of the vertical field component's polarity inversion line with height. The model yields strong initial rotations which saturate in the corona and differ qualitatively from the profile of rotation vs. height obtained in a recent simulation of an eruption without preexisting flux rope. Both major mechanisms writhe the flux rope axis, converting part of the initial twist helicity, and produce rotation profiles which, to a large part, are very similar within a range of shear-twist combinations. A difference lies in the tendency of twist-driven rotation to saturate at lower heights than shear-driven rotation. For parameters characteristic of the source regions of erupting filaments and coronal mass ejections, the shear field is found to be the dominant origin of rotations in the corona and to be required if the rotation reaches angles of order 90 degrees and higher; it dominates even if the twist exceeds the threshold of the helical kink instability. The contributions by shear and twist to the total rotation can be disentangled in the analysis of observations if the rotation and rise profiles are simultaneously compared with model calculations. The resulting twist estimate allows one to judge whether the helical kink instability occurred. This is demonstrated for the erupting prominence in the "Cartwheel CME" on 9 April 2008, which has shown a rotation of approximately 115 deg. up to a height of 1.5 Solar R above the photosphere. Out of a range of initial equilibria which include strongly kink-unstable (Phi = 5 pi), weakly kink-unstable (Phi = 3.5 pi), and kink-stable (Phi = 2.5 pi) configurations, only the evolution of the weakly kink-unstable flux rope matches the observations in their entirety.

  17. Seismic constraints on the radial dependence of the internal rotation profiles of six Kepler subgiants and young red giants

    NASA Astrophysics Data System (ADS)

    Deheuvels, S.; Doğan, G.; Goupil, M. J.; Appourchaux, T.; Benomar, O.; Bruntt, H.; Campante, T. L.; Casagrande, L.; Ceillier, T.; Davies, G. R.; De Cat, P.; Fu, J. N.; García, R. A.; Lobel, A.; Mosser, B.; Reese, D. R.; Regulo, C.; Schou, J.; Stahn, T.; Thygesen, A. O.; Yang, X. H.; Chaplin, W. J.; Christensen-Dalsgaard, J.; Eggenberger, P.; Gizon, L.; Mathis, S.; Molenda-Żakowicz, J.; Pinsonneault, M.

    2014-04-01

    Context. We still do not understand which physical mechanisms are responsible for the transport of angular momentum inside stars. The recent detection of mixed modes that contain the clear signature of rotation in the spectra of Kepler subgiants and red giants gives us the opportunity to make progress on this question. Aims: Our aim is to probe the radial dependence of the rotation profiles for a sample of Kepler targets. For this purpose, subgiants and early red giants are particularly interesting targets because their rotational splittings are more sensitive to the rotation outside the deeper core than is the case for their more evolved counterparts. Methods: We first extracted the rotational splittings and frequencies of the modes for six young Kepler red giants. We then performed a seismic modeling of these stars using the evolutionary codes Cesam2k and astec. By using the observed splittings and the rotational kernels of the optimal models, we inverted the internal rotation profiles of the six stars. Results: We obtain estimates of the core rotation rates for these stars, and upper limits to the rotation in their convective envelope. We show that the rotation contrast between the core and the envelope increases during the subgiant branch. Our results also suggest that the core of subgiants spins up with time, while their envelope spins down. For two of the stars, we show that a discontinuous rotation profile with a deep discontinuity reproduces the observed splittings significantly better than a smooth rotation profile. Interestingly, the depths that are found to be most probable for the discontinuities roughly coincide with the location of the H-burning shell, which separates the layers that contract from those that expand. Conclusions: We characterized the differential rotation pattern of six young giants with a range of metallicities, and with both radiative and convective cores on the main sequence. This will bring observational constraints to the scenarios of angular momentum transport in stars. Moreover, if the existence of sharp gradients in the rotation profiles of young red giants is confirmed, it is expected to help in distinguishing between the physical processes that could transport angular momentum in the subgiant and red giant branches. Appendices and Tables 3-9 are available in electronic form at http://www.aanda.org

  18. Analysis of preexistent vertebral rotation in the normal infantile, juvenile, and adolescent spine.

    PubMed

    Janssen, Michiel M A; Kouwenhoven, Jan-Willem M; Schlösser, Tom P C; Viergever, Max A; Bartels, Lambertus W; Castelein, René M; Vincken, Koen L

    2011-04-01

    Vertebral rotation was systematically analyzed in the normal, nonscoliotic thoracic spine of children aged 0 to 16 years. Subgroups were created to match the infantile, juvenile, and adolescent age groups according to the criteria of the Scoliosis Research Society. To determine whether a distinct pattern of vertebral rotation in the transverse plane exists in the normal, nonscoliotic infantile, juvenile, and adolescent spine. We assume that, once the spine starts to deteriorate into a scoliotic deformity, it will follow a preexisting rotational pattern. Recently, we identified a rotational pattern in the normal nonscoliotic adult spine that corresponds to the most common curve types in adolescent idiopathic scoliosis. In infantile idiopathic scoliosis, curves are typically left sided and boys are affected more often than girls, whereas in adolescent idiopathic scoliosis, the thoracic curve is typically right sided and predominantly girls are affected. The present study is the first systematic analysis of vertebral rotation in the normal children's spine. Vertebral rotation in the transverse plane of T2-T12 was measured by using a semiautomatic method on 146 computed tomographic scans of children (0-16 years old) without clinical or radiologic evidence of spinal pathology. Scans were mainly made for reasons such as recurrent respiratory tract infections, malignancies, or immune disorders. Vertebral rotational patterns were analyzed in the infantile (0-3-year-old), juvenile (4-9-year-old), and adolescent (10-16-year-old) boys and girls. In the infantile spine, vertebrae T2-T6 were significantly rotated to the left (P < 0.001). In the juvenile spine, T4 was significantly rotated to the left. In the adolescent spine, T6-T12 were significantly rotated to the right (P ≤ 0.001). Rotation to the left was more pronounced in infantile boys than in the girls (P = 0.023). In juvenile and adolescent children, no statistical differences in rotation were found between the sexes. These data support the hypothesis that the direction of the spinal curve in idiopathic scoliosis is determined by the built-in rotational pattern that the spine exhibits at the time of onset. The well-known predominance of right-sided thoracic curves in adolescent idiopathic scoliosis and left-sided curves in infantile idiopathic scoliosis can be explained by the observed patterns of vertebral rotation that preexist at the corresponding age.

  19. The use of a robotic tibial rotation device and an electromagnetic tracking system to accurately reproduce the clinical dial test.

    PubMed

    Stinton, S K; Siebold, R; Freedberg, H; Jacobs, C; Branch, T P

    2016-03-01

    The purpose of this study was to: (1) determine whether a robotic tibial rotation device and an electromagnetic tracking system could accurately reproduce the clinical dial test at 30° of knee flexion; (2) compare rotation data captured at the footplates of the robotic device to tibial rotation data measured using an electromagnetic sensor on the proximal tibia. Thirty-two unilateral ACL-reconstructed patients were examined using a robotic tibial rotation device that mimicked the dial test. The data reported in this study is only from the healthy legs of these patients. Torque was applied through footplates and was measured using servomotors. Lower leg motion was measured at the foot using the motors. Tibial motion was also measured through an electromagnetic tracking system and a sensor on the proximal tibia. Load-deformation curves representing rotational motion of the foot and tibia were compared using Pearson's correlation coefficients. Off-axis motions including medial-lateral translation and anterior-posterior translation were also measured using the electromagnetic system. The robotic device and electromagnetic system were able to provide axial rotation data and translational data for the tibia during the dial test. Motion measured at the foot was not correlated to motion of the tibial tubercle in internal rotation or in external rotation. The position of the tibial tubercle was 26.9° ± 11.6° more internally rotated than the foot at torque 0 Nm. Medial-lateral translation and anterior-posterior translation were combined to show the path of the tubercle in the coronal plane during tibial rotation. The information captured during a manual dial test includes both rotation of the tibia and proximal tibia translation. All of this information can be captured using a robotic tibial axial rotation device with an electromagnetic tracking system. The pathway of the tibial tubercle during tibial axial rotation can provide additional information about knee instability without relying on side-to-side comparison between knees. The translation of the proximal tibia is important information that must be considered in addition to axial rotation of the tibia when performing a dial test whether done manually or with a robotic device. Instrumented foot position cannot provide the same information. IV.

  20. General surgery resident rotations in surgical critical care, trauma, and burns: what is optimal for residency training?

    PubMed

    Napolitano, Lena M; Biester, Thomas W; Jurkovich, Gregory J; Buyske, Jo; Malangoni, Mark A; Lewis, Frank R

    2016-10-01

    There are no specific Accreditation Council for Graduate Medical Education General Surgery Residency Program Requirements for rotations in surgical critical care (SCC), trauma, and burn. We sought to determine the experience of general surgery residents in SCC, trauma, and burn rotations. Data analysis of surgical rotations of American Board of Surgery general surgery resident applicants (n = 7,299) for the last 8 years (2006 to 2013, inclusive) was performed through electronic applications to the American Board of Surgery Qualifying Examination. Duration (months) spent in SCC, trauma, and burn rotations, and postgraduate year (PGY) level were examined. The total months in SCC, trauma and burn rotations was mean 10.2 and median 10.0 (SD 3.9 months), representing approximately 16.7% (10 of 60 months) of a general surgery resident's training. However, there was great variability (range 0 to 29 months). SCC rotation duration was mean 3.1 and median 3.0 months (SD 2, min to max: 0 to 15), trauma rotation duration was mean 6.3 and median 6.0 months (SD 3.5, min to max: 0 to 24), and burn rotation duration was mean 0.8 and median 1.0 months (SD 1.0, min to max: 0 to 6). Of the total mean 10.2 months duration, the longest exposure was 2 months as PGY-1, 3.4 months as PGY-2, 1.9 months as PGY-3, 2.2 months as PGY-4 and 1.1 months as PGY-5. PGY-5 residents spent a mean of 1 month in SCC, trauma, and burn rotations. PGY-4/5 residents spent the majority of this total time in trauma rotations, whereas junior residents (PGY-1 to 3) in SCC and trauma rotations. There is significant variability in total duration of SCC, trauma, and burn rotations and PGY level in US general surgery residency programs, which may result in significant variability in the fund of knowledge and clinical experience of the trainee completing general surgery residency training. As acute care surgery programs have begun to integrate emergency general surgery with SCC, trauma, and burn rotations, it is an ideal time to determine the optimal curriculum and duration of these important rotations for general surgery residency training. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Spin-stabilized magnetic levitation without vertical axis of rotation

    DOEpatents

    Romero, Louis [Albuquerque, NM; Christenson, Todd [Albuquerque, NM; Aaronson, Gene [Albuquerque, NM

    2009-06-09

    The symmetry properties of a magnetic levitation arrangement are exploited to produce spin-stabilized magnetic levitation without aligning the rotational axis of the rotor with the direction of the force of gravity. The rotation of the rotor stabilizes perturbations directed parallel to the rotational axis.

  2. Two Routes to Expertise in Mental Rotation

    ERIC Educational Resources Information Center

    Provost, Alexander; Johnson, Blake; Karayanidis, Frini; Brown, Scott D.; Heathcote, Andrew

    2013-01-01

    The ability to imagine objects undergoing rotation (mental rotation) improves markedly with practice, but an explanation of this plasticity remains controversial. Some researchers propose that practice speeds up the rate of a general-purpose rotation algorithm. Others maintain that performance improvements arise through the adoption of a new…

  3. Rotating plug bearing and seal

    DOEpatents

    Wade, Elman E.

    1977-01-01

    A bearing and seal structure for nuclear reactors utilizing rotating plugs above the nuclear reactor vessel. The structure permits lubrication of bearings and seals of the rotating plugs without risk of the lubricant draining into the reactor vessel below. The structure permits lubrication by utilizing a rotating outer race bearing.

  4. Effect of viewing distance and location of the axis of head rotation on the monkey's vestibuloocular reflex. I. Eye movement responses.

    PubMed

    Snyder, L H; King, W M

    1992-04-01

    1. The vestibuloocular reflex (VOR) stabilizes images on the retina against movements of the head in space. Viewing distance, target eccentricity, and location of the axis of rotation may influence VOR responses because rotation of the head about most axes in space rotates and translates the eyes relative to visual targets. To study the VOR response to combined rotation and translation, monkeys were placed on a rate table and rotated briefly in the dark about a vertical axis that was located in front of or behind the eyes. The monkeys fixated a near or far visual target that was extinguished before the rotation. Eye movements were recorded from both eyes by the use of the search coil technique. 2. Peak eye velocity evoked by the VOR was linearly related to vergence angle for any axis of rotation. The percent change in the VOR with near target viewing relative to far target viewing at a vergence angle of 20 degrees was linearly related to the location of the axis of rotation. Axes located behind the eyes produced positive changes in VOR amplitude, and axes located in front of the eyes produced negative changes in VOR amplitude. An axis of rotation located in the coronal plane containing the centers of rotation of the eyes produced no modification of VOR amplitude. For any axis, the VOR compensated for approximately 90% of the translation of the eye relative to near targets. 3. The initial VOR response was not correct in magnitude but was refined by a series of three temporally delayed corrections of increasing complexity. The earliest VOR-evoked eye movement (10-20 ms after rotation onset) was independent of viewing distance and rotational axis location. In the next 100 ms, eye speed appeared to be sequentially modified three times: within 20 ms by viewing distance; within 30 ms by otolith translation; and within 100 ms by eye translation relative to the visual target. 4. These data suggest a formal model of the VOR consisting of four channels. Channel 1 conveys an unmodified head rotation signal with a pure delay of 10 ms. Channel 2 conveys an angular head velocity signal, modified by viewing distance with a pure delay of 20 ms, but invariant with respect to the location of the axis of rotation. Channel 3 conveys a linear head velocity signal, dependent on the location of the axis of rotation, that is modified by viewing distance with a pure delay of 30 ms.(ABSTRACT TRUNCATED AT 400 WORDS)

  5. Self-defrosting recuperative air-to-air heat exchanger

    DOEpatents

    Drake, Richard L.

    1993-01-01

    A heat exchanger includes a stationary spirally or concentrically wound heat exchanger core with rotating baffles on upper and lower ends thereof. The rotating baffles include rotating inlets and outlets which are in communication with respective fixed inlets and outlets via annuli. The rotation of the baffles causes a concurrent rotation of the temperature distribution within the stationary exchanger core, thereby preventing frost build-up in some applications and preventing the formation of hot spots in other applications.

  6. Modeling of Prosthetic Limb Rotation Control by Sensing Rotation of Residual Arm Bone

    PubMed Central

    Kuiken, Todd A.

    2011-01-01

    We proposed a new approach to improve the control of prosthetic arm rotation in amputees. Arm rotation is sensed by implanting a small permanent magnet into the distal end of the residual bone, which produces a magnetic field. The position of the bone rotation can be derived from magnetic field distribution detected with magnetic sensors on the arm surface, and then conveyed to the prosthesis controller to manipulate the rotation of the prosthesis. Proprioception remains intact for residual limb skeletal structures; thus, this control system should be natural and easy-to-use. In this study, simulations have been conducted in an upper arm model to assess the feasibility and performance of sensing the voluntary rotation of residual humerus with an implanted magnet. A sensitivity analysis of the magnet size and arm size was presented. The influence of relative position of the magnet to the magnetic sensors, orientation of the magnet relative to the limb axis, and displacement of the magnetic sensors on the magnetic field was evaluated. The performance of shielding external magnetostatic interference was also investigated. The simulation results suggest that the direction and angle of rotation of residual humerus could be obtained by decoding the magnetic field signals with magnetic sensors built into a prosthetic socket. This pilot study provides important guidelines for developing a practical interface between the residual bone rotation and the prosthesis for control of prosthetic rotation. PMID:18713682

  7. Effect of direction of head movement on motion sickness caused by Coriolis stimulation.

    PubMed

    Woodman, P D; Griffin, M J

    1997-02-01

    During constant speed rotation of the body, head rotation about an axis other than the axis of rotation of the body (i.e., Coriolis is stimulation) induces motion sickness. The position of the body relative to the center of rotation will influence the sickness caused by Coriolis stimulation; the direction of head movement will not affect the sickness caused by Coriolis stimulation. There were 24 seated subjects (12 male, 12 female) who made 30 degrees pitch motions of the head every 30 s while rotating about a vertical axis at 10 r.p.m. on a turntable at two separate locations: a) at the center of rotation; and b) 0.75 m from the center of rotation. After each head movement the subjects gave ratings of motion illness. There was no significant difference between illness 0.75 m from the center of rotation and illness at the center of rotation, or between the illness ratings from male and female subjects. Moving the head up from the horizontal caused significantly fewer increases in ratings of motion illness than moving the head back down to the horizontal. Precise location of the body at the center of rotation is not critical during Coriolis stimulation, but the direction of head movement has a large effect on nausea. An influence of somatosensory information on sickness caused by Coriolis stimulation is suggested.

  8. Rotation of vertically oriented objects during earthquakes

    NASA Astrophysics Data System (ADS)

    Hinzen, Klaus-G.

    2012-10-01

    Vertically oriented objects, such as tombstones, monuments, columns, and stone lanterns, are often observed to shift and rotate during earthquake ground motion. Such observations are usually limited to the mesoseismal zone. Whether near-field rotational ground motion components are necessary in addition to pure translational movements to explain the observed rotations is an open question. We summarize rotation data from seven earthquakes between 1925 and 2009 and perform analog and numeric rotation testing with vertically oriented objects. The free-rocking motion of a marble block on a sliding table is disturbed by a pulse in the direction orthogonal to the rocking motion. When the impulse is sufficiently strong and occurs at the `right' moment, it induces significant rotation of the block. Numeric experiments of a free-rocking block show that the initiation of vertical block rotation by a cycloidal acceleration pulse applied orthogonal to the rocking axis depends on the amplitude of the pulse and its phase relation to the rocking cycle. Rotation occurs when the pulse acceleration exceeds the threshold necessary to provoke rocking of a resting block, and the rocking block approaches its equilibrium position. Experiments with blocks subjected to full 3D strong motion signals measured during the 2009 L'Aquila earthquake confirm the observations from the tests with analytic ground motions. Significant differences in the rotational behavior of a monolithic block and two stacked blocks exist.

  9. Symmetric rotating-wave approximation for the generalized single-mode spin-boson system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albert, Victor V.; Scholes, Gregory D.; Brumer, Paul

    2011-10-15

    The single-mode spin-boson model exhibits behavior not included in the rotating-wave approximation (RWA) in the ultra and deep-strong coupling regimes, where counter-rotating contributions become important. We introduce a symmetric rotating-wave approximation that treats rotating and counter-rotating terms equally, preserves the invariances of the Hamiltonian with respect to its parameters, and reproduces several qualitative features of the spin-boson spectrum not present in the original rotating-wave approximation both off-resonance and at deep-strong coupling. The symmetric rotating-wave approximation allows for the treatment of certain ultra- and deep-strong coupling regimes with similar accuracy and mathematical simplicity as does the RWA in the weak-coupling regime.more » Additionally, we symmetrize the generalized form of the rotating-wave approximation to obtain the same qualitative correspondence with the addition of improved quantitative agreement with the exact numerical results. The method is readily extended to higher accuracy if needed. Finally, we introduce the two-photon parity operator for the two-photon Rabi Hamiltonian and obtain its generalized symmetric rotating-wave approximation. The existence of this operator reveals a parity symmetry similar to that in the Rabi Hamiltonian as well as another symmetry that is unique to the two-photon case, providing insight into the mathematical structure of the two-photon spectrum, significantly simplifying the numerics, and revealing some interesting dynamical properties.« less

  10. Intraplate Crustal Deformation Within the Northern Sinai Microplate: Evidence from Paleomagnetic Directions and Mechanical Modeling

    NASA Astrophysics Data System (ADS)

    Dembo, N.; Granot, R.; Hamiel, Y.

    2017-12-01

    The intraplate crustal deformation found in the northern part of the Sinai Microplate, located near the northern Dead Sea Fault plate boundary, is examined. Previous studies have suggested that distributed deformation in Lebanon is accommodated by regional uniform counterclockwise rigid block rotations. However, remanent magnetization directions observed near the Lebanese restraining bend are not entirely homogeneous suggesting that an unexplained and complex internal deformation pattern exists. In order to explain the variations in the amount of vertical-axis rotations we construct a mechanical model of the major active faults in the region that simulates the rotational deformation induced by motion along these faults. The rotational pattern calculated by the mechanical modeling predicts heterogeneous distribution of rotations around the faults. The combined rotation field that considers both the fault induced rotations and the already suggested regional block rotations stands in general agreement with the observed magnetization directions. Overall, the modeling results provide a more detailed and complete picture of the deformation pattern in this region and show that rotations induced by motion along the Dead Sea Fault act in parallel to rigid block rotations. Finally, the new modeling results unravel important insights as to the fashion in which crustal deformation is distributed within the northern part of the Sinai Microplate and propose an improved deformational mechanism that might be appropriate for other plate margins as well.

  11. Understanding and predicting profile structure and parametric scaling of intrinsic rotation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, W. X.; Grierson, B. A.; Ethier, S.

    2017-08-10

    This study reports on a recent advance in developing physical understanding and a first-principles-based model for predicting intrinsic rotation profiles in magnetic fusion experiments. It is shown for the first time that turbulent fluctuation-driven residual stress (a non-diffusive component of momentum flux) along with diffusive momentum flux can account for both the shape and magnitude of the observed intrinsic toroidal rotation profile. Both the turbulence intensity gradient and zonal flow E×B shear are identified as major contributors to the generation of the k ∥-asymmetry needed for the residual stress generation. The model predictions of core rotation based on global gyrokineticmore » simulations agree well with the experimental measurements of main ion toroidal rotation for a set of DIII-D ECH discharges. The validated model is further used to investigate the characteristic dependence of residual stress and intrinsic rotation profile structure on the multi-dimensional parametric space covering the turbulence type, q-profile structure, and up-down asymmetry in magnetic geometry with the goal of developing the physics understanding needed for rotation profile control and optimization. It is shown that in the flat-q profile regime, intrinsic rotations driven by ITG and TEM turbulence are in the opposite direction (i.e., intrinsic rotation reverses). The predictive model also produces reversed intrinsic rotation for plasmas with weak and normal shear q-profiles.« less

  12. Gastight Hydrodynamic Electrochemistry: Design for a Hermetically Sealed Rotating Disk Electrode Cell.

    PubMed

    Jung, Suho; Kortlever, Ruud; Jones, Ryan J R; Lichterman, Michael F; Agapie, Theodor; McCrory, Charles C L; Peters, Jonas C

    2017-01-03

    Rotating disk electrodes (RDEs) are widely used in electrochemical characterization to analyze the mechanisms of various electrocatalytic reactions. RDE experiments often make use of or require collection and quantification of gaseous products. The combination of rotating parts and gaseous analytes makes the design of RDE cells that allow for headspace analysis challenging due to gas leaks at the interface of the cell body and the rotator. In this manuscript we describe a new, hermetically sealed electrochemical cell that allows for electrode rotation while simultaneously providing a gastight environment. Electrode rotation in this new cell design is controlled by magnetically coupling the working electrode to a rotating magnetic driver. Calibration of the RDE using a tachometer shows that the rotation speed of the electrode is the same as that of the magnetic driver. To validate the performance of this cell for hydrodynamic measurements, limiting currents from the reduction of a potassium ferrocyanide (K 4 [Fe(CN) 6 ]·3H 2 O) were measured and shown to compare favorably with calculated values from the Levich equation and with data obtained using more typical, nongastight RDE cells. Faradaic efficiencies of ∼95% were measured in the gas phase for oxygen evolution in alkaline media at an Inconel 625 alloy electrocatalyst during rotation at 1600 rpm. These data verify that a gastight environment is maintained even during rotation.

  13. Rotation-invariant image and video description with local binary pattern features.

    PubMed

    Zhao, Guoying; Ahonen, Timo; Matas, Jiří; Pietikäinen, Matti

    2012-04-01

    In this paper, we propose a novel approach to compute rotation-invariant features from histograms of local noninvariant patterns. We apply this approach to both static and dynamic local binary pattern (LBP) descriptors. For static-texture description, we present LBP histogram Fourier (LBP-HF) features, and for dynamic-texture recognition, we present two rotation-invariant descriptors computed from the LBPs from three orthogonal planes (LBP-TOP) features in the spatiotemporal domain. LBP-HF is a novel rotation-invariant image descriptor computed from discrete Fourier transforms of LBP histograms. The approach can be also generalized to embed any uniform features into this framework, and combining the supplementary information, e.g., sign and magnitude components of the LBP, together can improve the description ability. Moreover, two variants of rotation-invariant descriptors are proposed to the LBP-TOP, which is an effective descriptor for dynamic-texture recognition, as shown by its recent success in different application problems, but it is not rotation invariant. In the experiments, it is shown that the LBP-HF and its extensions outperform noninvariant and earlier versions of the rotation-invariant LBP in the rotation-invariant texture classification. In experiments on two dynamic-texture databases with rotations or view variations, the proposed video features can effectively deal with rotation variations of dynamic textures (DTs). They also are robust with respect to changes in viewpoint, outperforming recent methods proposed for view-invariant recognition of DTs.

  14. Perceptual Strategies of Pigeons to Detect a Rotational Centre—A Hint for Star Compass Learning?

    PubMed Central

    Helduser, Sascha; Mouritsen, Henrik; Güntürkün, Onur

    2015-01-01

    Birds can rely on a variety of cues for orientation during migration and homing. Celestial rotation provides the key information for the development of a functioning star and/or sun compass. This celestial compass seems to be the primary reference for calibrating the other orientation systems including the magnetic compass. Thus, detection of the celestial rotational axis is crucial for bird orientation. Here, we use operant conditioning to demonstrate that homing pigeons can principally learn to detect a rotational centre in a rotating dot pattern and we examine their behavioural response strategies in a series of experiments. Initially, most pigeons applied a strategy based on local stimulus information such as movement characteristics of single dots. One pigeon seemed to immediately ignore eccentric stationary dots. After special training, all pigeons could shift their attention to more global cues, which implies that pigeons can learn the concept of a rotational axis. In our experiments, the ability to precisely locate the rotational centre was strongly dependent on the rotational velocity of the dot pattern and it crashed at velocities that were still much faster than natural celestial rotation. We therefore suggest that the axis of the very slow, natural, celestial rotation could be perceived by birds through the movement itself, but that a time-delayed pattern comparison should also be considered as a very likely alternative strategy. PMID:25807499

  15. Neoclassical poloidal and toroidal rotation in tokamaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Y.B.; Diamond, P.H.; Groebner, R.J.

    1991-08-01

    Explicit expressions for the neoclassical poloidal and toroidal rotation speeds of primary ion and impurity species are derived via the Hirshman and Sigmar moment approach. The rotation speeds of the primary ion can be significantly different from those of impurities in various interesting cases. The rapid increase of impurity poloidal rotation in the edge region of H-mode discharges in tokamaks can be explained by a rapid steepening of the primary ion pressure gradient. Depending on ion collisionality, the poloidal rotation speed of the primary ions at the edge can be quite small and the flow direction may be opposite tomore » that of the impurities. This may cast considerable doubts on current L to H bifurcation models based on primary ion poloidal rotation only. Also, the difference between the toroidal rotation velocities of primary ions and impurities is not negligible in various cases. In Ohmic plasmas, the parallel electric field induces a large impurity toroidal rotation close to the magnetic axis, which seems to agree with experimental observations. In the ion banana and plateau regime, there can be non-negligible disparities between primary ion and impurity toroidal rotation velocities due to the ion density and temperature gradients. Detailed analytic expressions for the primary ion and impurity rotation speeds are presented, and the methodology for generalization to the case of several impurity species is also presented for future numerical evaluation.« less

  16. ON THE ROTATION OF SUNSPOTS AND THEIR MAGNETIC POLARITY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, Jianchuan; Yang, Zhiliang; Guo, Kaiming

    2016-07-20

    The rotation of sunspots of 2 yr in two different solar cycles is studied with the data from the Helioseismic and Magnetic Imager on board the Solar Dynamics Observatory and the Michelson Doppler Imager instrument on board the Solar and Heliospheric Observataory . We choose the α sunspot groups and the relatively large and stable sunspots of complex active regions in our sample. In the year of 2003, the α sunspot groups and the preceding sunspots tend to rotate counterclockwise and have positive magnetic polarity in the northern hemisphere. In the southern hemisphere, the magnetic polarity and rotational tendency ofmore » the α sunspot groups and the preceding sunspots are opposite to the northern hemisphere. The average rotational speed of these sunspots in 2003 is about 0.°65 hr{sup 1}. From 2014 January to 2015 February, the α sunspot groups and the preceding sunspots tend to rotate clockwise and have negative magnetic polarity in the northern hemisphere. The patterns of rotation and magnetic polarity of the southern hemisphere are also opposite to those of the northern hemisphere. The average rotational speed of these sunspots in 2014/2015 is about 1.°49 hr{sup 1}. The rotation of the relatively large and stable preceding sunspots and that of the α sunspot groups located in the same hemisphere have opposite rotational direction in 2003 and 2014/2015.« less

  17. STRONG DEPENDENCE OF THE INNER EDGE OF THE HABITABLE ZONE ON PLANETARY ROTATION RATE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Jun; Abbot, Dorian S.; Boué, Gwenaël

    2014-05-20

    Planetary rotation rate is a key parameter in determining atmospheric circulation and hence the spatial pattern of clouds. Since clouds can exert a dominant control on planetary radiation balance, rotation rate could be critical for determining the mean planetary climate. Here we investigate this idea using a three-dimensional general circulation model with a sophisticated cloud scheme. We find that slowly rotating planets (like Venus) can maintain an Earth-like climate at nearly twice the stellar flux as rapidly rotating planets (like Earth). This suggests that many exoplanets previously believed to be too hot may actually be habitable, depending on their rotationmore » rate. The explanation for this behavior is that slowly rotating planets have a weak Coriolis force and long daytime illumination, which promotes strong convergence and convection in the substellar region. This produces a large area of optically thick clouds, which greatly increases the planetary albedo. In contrast, on rapidly rotating planets a much narrower belt of clouds form in the deep tropics, leading to a relatively low albedo. A particularly striking example of the importance of rotation rate suggested by our simulations is that a planet with modern Earth's atmosphere, in Venus' orbit, and with modern Venus' (slow) rotation rate would be habitable. This would imply that if Venus went through a runaway greenhouse, it had a higher rotation rate at that time.« less

  18. The effect of different screw-rod design on the anti-rotational torque: a biomechanical comparison of three conventional screw-rod constructs.

    PubMed

    Huang, Zifang; Wang, Chongwen; Fan, Hengwei; Sui, Wenyuan; Li, Xueshi; Wang, Qifei; Yang, Junlin

    2017-07-28

    Screw-rod constructs have been widely used to correct spinal deformities, but the effects of different screw-rod systems on anti-rotational torque have not been determined. This study aimed to analyze the biomechanical effect of different rod-screw constructs on anti-rotational torque. Three conventional spinal screw-rod systems (Legacy, RF-F-10 and USSII) were used to test the anti-rotational torque in the material test machine. ANOVA was performed to evaluate the anti-rotational capacity of different pedicle screws-rod constructs. The anti-rotational torque of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm, with a P value lower than 0.05. This results indicated that the Legacy screws-rod construct could provide a highest anti-rotation capacity, which is 68% and 210% greater than RF-F-10 screw-rod construct and USSII screw-rod respectively. The anti-rotational torque may be mainly affected by screw cap and groove design. Our result showed the anti-rotational torque are: Legacy system > RF-F-10 system > USSII system, suggesting that appropriate rod-screw constructs selection in surgery may be vital for anti-rotational torque improvement and preventing derotation correction loss.

  19. Rotational actuator of motor based on carbon nanotubes

    DOEpatents

    Zettl, Alexander K.; Fennimore, Adam M.; Yuzvinsky, Thomas D.

    2008-11-18

    A rotational actuator/motor based on rotation of a carbon nanotube is disclosed. The carbon nanotube is provided with a rotor plate attached to an outer wall, which moves relative to an inner wall of the nanotube. After deposit of a nanotube on a silicon chip substrate, the entire structure may be fabricated by lithography using selected techniques adapted from silicon manufacturing technology. The structures to be fabricated may comprise a multiwall carbon nanotube (MWNT), two in plane stators S1, S2 and a gate stator S3 buried beneath the substrate surface. The MWNT is suspended between two anchor pads and comprises a rotator attached to an outer wall and arranged to move in response to electromagnetic inputs. The substrate is etched away to allow the rotor to freely rotate. Rotation may be either in a reciprocal or fully rotatable manner.

  20. RoboPol: connection between optical polarization plane rotations and gamma-ray flares in blazars

    NASA Astrophysics Data System (ADS)

    Blinov, D.; Pavlidou, V.; Papadakis, I.; Kiehlmann, S.; Liodakis, I.; Panopoulou, G. V.; Angelakis, E.; Baloković, M.; Hovatta, T.; King, O. G.; Kus, A.; Kylafis, N.; Mahabal, A.; Maharana, S.; Myserlis, I.; Paleologou, E.; Papamastorakis, I.; Pazderski, E.; Pearson, T. J.; Ramaprakash, A.; Readhead, A. C. S.; Reig, P.; Tassis, K.; Zensus, J. A.

    2018-02-01

    We use results of our 3 yr polarimetric monitoring programme to investigate the previously suggested connection between rotations of the polarization plane in the optical emission of blazars and their gamma-ray flares in the GeV band. The homogeneous set of 40 rotation events in 24 sources detected by RoboPol is analysed together with the gamma-ray data provided by Fermi-LAT. We confirm that polarization plane rotations are indeed related to the closest gamma-ray flares in blazars and the time lags between these events are consistent with zero. Amplitudes of the rotations are anticorrelated with amplitudes of the gamma-ray flares. This is presumably caused by higher relativistic boosting (higher Doppler factors) in blazars that exhibit smaller amplitude polarization plane rotations. Moreover, the time-scales of rotations and flares are marginally correlated.

  1. The Maximum Mass of Rotating Strange Stars

    NASA Astrophysics Data System (ADS)

    Szkudlarek, M.; Gondek-Rosiń; ska, D.; Villain, L.; Ansorg, M.

    2012-12-01

    Strange quark stars are considered as a possible alternative to neutron stars as compact objects (e.g. Weber 2003). A hot compact star (a proto-neutron star or a strange star) born in a supernova explosion or a remnant of neutron stars binary merger are expected to rotate differentially and be important sources of gravitational waves. We present results of the first relativistic calculations of differentially rotating strange quark stars for broad ranges of degree of differential rotation and maximum densities. Using a highly accurate, relativistic code we show that rotation may cause a significant increase of maximum allowed mass of strange stars, much larger than in the case of neutron stars with the same degree of differential rotation. Depending on the maximum allowed mass a massive neutron star (strange star) can be temporarily stabilized by differential rotation or collapse to a black hole.

  2. Influence of toroidal rotation on resistive tearing modes in tokamaks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, S.; Ma, Z. W., E-mail: zwma@zju.edu.cn

    Influence of toroidal equilibrium plasma rotation on m/n = 2/1 resistive tearing modes is studied numerically using a 3D toroidal MHD code (CLT). It is found that the toroidal rotation with or without shear can suppress the tearing instability and the Coriolis effect in the toroidal geometry plays a dominant role on the rotation induced stabilization. For a high viscosity plasma (τ{sub R}/τ{sub V} ≫ 1, where τ{sub R} and τ{sub V} represent resistive and viscous diffusion time, respectively), the effect of the rotation shear combined with the viscosity appears to be stabilizing. For a low viscosity plasmas (τ{sub R}/τ{sub V} ≪ 1), the rotation shearmore » shows a destabilizing effect when the rotation is large.« less

  3. Rotational actuator or motor based on carbon nanotubes

    DOEpatents

    Zetti, Alexander K.; Fennimore, Adam M.; Yuzvinsky, Thomas D.

    2006-05-30

    A rotational actuator/motor based on rotation of a carbon nanotube is disclosed. The carbon nanotube is provided with a rotor plate attached to an outer wall, which moves relative to an inner wall of the nanotube. After deposit of a nanotube on a silicon chip substrate, the entire structure may be fabricated by lithography using selected techniques adapted from silicon manufacturing technology. The structures to be fabricated may comprise a multiwall carbon nanotube (MWNT), two in plane stators S1, S2 and a gate stator S3 buried beneath the substrate surface. The MWNT is suspended between two anchor pads and comprises a rotator attached to an outer wall and arranged to move in response to electromagnetic inputs. The substrate is etched away to allow the rotor to freely rotate. Rotation may be either in a reciprocal or fully rotatable manner.

  4. Effect of steady crucible rotation on the segregation of impurities in vertical Bridgman growth of multi-crystalline silicon

    NASA Astrophysics Data System (ADS)

    Bellmann, M. P.; Meese, E. A.

    2011-10-01

    We have performed axisymmetric, transient simulations of the vertical Bridgman growth of multi-crystalline (mc) silicon to study the effect of the steady crucible rotation on the melt flow and impurity segregation. A solute transport model has been applied to predict the final segregation pattern of impurities in a circular ingot. Imposing rotation rates of 1-5 rpm on the system makes radial segregation much worse compared to the non-rotating case. Low rotation rates at 1-2 rpm increase radial segregation in the first half period of solidification, whereas at rotation rates above the effect is insignificantly small. Contrary behavior was observed for the second half period of solidification. Here radial segregation is increased at high rotation rates from 3 to 5 rpm with small impact at 1-2 rpm.

  5. Andreas Vesalius' five hundreth anniversary: initiation of the rotator cuff concept.

    PubMed

    Brinkman, Romy J; Hage, J Joris

    2015-12-01

    The rotator cuff concept refers to the four scapulohumeral muscles that stabilize and rotate the humerus relative to the scapula. To date, the first description of the rotator cuff remained unidentified. In light of the 500th birthday of Andreas Vesalius (1515-1564) we searched his 1543 masterwork "Fabrica Corporis Humani Libri Septem" for references to the morphology and function of the rotator cuff muscles. Even though he distinguished three rather than four scapulohumeral muscles, Vesalius recognized the need for structures that prevent dislocation of the shoulder inherent to the morphology of the humeral caput and scapular socket. He recorded "three strong ligaments" and the "three muscles that rotate the arm" of which the tendons completely "embrace the ligaments of the joint" as such structures. Vesalius defined the rotator cuff concept avant la lettre.

  6. Mechanical seal assembly

    DOEpatents

    Kotlyar, Oleg M.

    2001-01-01

    An improved mechanical seal assembly is provided for sealing rotating shafts with respect to their shaft housings, wherein the rotating shafts are subject to substantial axial vibrations. The mechanical seal assembly generally includes a rotating sealing ring fixed to the shaft, a non-rotating sealing ring adjacent to and in close contact with the rotating sealing ring for forming an annular seal about the shaft, and a mechanical diode element that applies a biasing force to the non-rotating sealing ring by means of hemispherical joint. The alignment of the mechanical diode with respect to the sealing rings is maintained by a series of linear bearings positioned axially along a desired length of the mechanical diode. Alternative embodiments include mechanical or hydraulic amplification components for amplifying axial displacement of the non-rotating sealing ring and transferring it to the mechanical diode.

  7. Mechanical seal assembly

    DOEpatents

    Kotlyar, Oleg M.

    2002-01-01

    An improved mechanical seal assembly is provided for sealing rotating shafts with respect to their shaft housings, wherein the rotating shafts are subject to substantial axial vibrations. The mechanical seal assembly generally includes a rotating sealing ring fixed to the shaft, a non-rotating sealing ring adjacent to and in close contact with the rotating sealing ring for forming an annular seal about the shaft, and a mechanical diode element that applies a biasing force to the non-rotating sealing ring by means of hemispherical joint. The alignment of the mechanical diode with respect to the sealing rings is maintained by a series of linear bearings positioned axially along a desired length of the mechanical diode. Alternative embodiments include mechanical or hydraulic amplification components for amplifying axial displacement of the non-rotating sealing ring and transfering it to the mechanical diode.

  8. Recognition of rotated images using the multi-valued neuron and rotation-invariant 2D Fourier descriptors

    NASA Astrophysics Data System (ADS)

    Aizenberg, Evgeni; Bigio, Irving J.; Rodriguez-Diaz, Eladio

    2012-03-01

    The Fourier descriptors paradigm is a well-established approach for affine-invariant characterization of shape contours. In the work presented here, we extend this method to images, and obtain a 2D Fourier representation that is invariant to image rotation. The proposed technique retains phase uniqueness, and therefore structural image information is not lost. Rotation-invariant phase coefficients were used to train a single multi-valued neuron (MVN) to recognize satellite and human face images rotated by a wide range of angles. Experiments yielded 100% and 96.43% classification rate for each data set, respectively. Recognition performance was additionally evaluated under effects of lossy JPEG compression and additive Gaussian noise. Preliminary results show that the derived rotation-invariant features combined with the MVN provide a promising scheme for efficient recognition of rotated images.

  9. Interplay between intrinsic plasma rotation and magnetic island evolution in disruptive discharges

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ronchi, G.; Severo, J. H. F.; Salzedas, F.

    The behavior of the intrinsic toroidal rotation of the plasma column during the growth and eventual saturation of m/n = 2/1 magnetic islands, triggered by programmed density rise, has been carefully investigated in disruptive discharges in TCABR. The results show that, as the island starts to grow and rotate at a speed larger than that of the plasma column, the angular frequency of the intrinsic toroidal rotation increases and that of the island decreases, following the expectation of synchronization. As the island saturates at a large size, just before a major disruption, the angular speed of the intrinsic rotation decreasesmore » quite rapidly, even though the island keeps still rotating at a reduced speed. This decrease of the toroidal rotation is quite reproducible and can be considered as an indicative of disruption.« less

  10. Differential rotation in Jupiter: A comparison of methods

    NASA Astrophysics Data System (ADS)

    Wisdom, J.; Hubbard, W. B.

    2016-03-01

    Whether Jupiter rotates as a solid body or has some element of differential rotation along concentric cylinders is unknown. But Jupiter's zonal wind is not north/south symmetric so at most some average of the north/south zonal winds could be an expression of cylinders. Here we explore the signature in the gravitational moments of such a smooth differential rotation. We carry out this investigation with two general methods for solving for the interior structure of a differentially rotating planet: the CMS method of Hubbard (Hubbard, W.B. [2013]. Astrophys. J. 768, 1-8) and the CLC method of Wisdom (Wisdom, J. [1996]. Non-Perturbative Hydrostatic Equilibrium. http://web.mit.edu/wisdom/www/interior.pdf). The two methods are in remarkable agreement. We find that for smooth differential rotation the moments do not level off as they do for strong differential rotation.

  11. Lagrangian particle drift and surface deformation in a rotating wave on a free liquid surface

    NASA Astrophysics Data System (ADS)

    Fontana, Paul W.; Francois, Nicolas; Xia, Hua; Punzmann, Horst; Shats, Michael

    2017-11-01

    A nonlinear model of a rotating wave on the free surface of a liquid is presented. The flow is assumed to be inviscid and irrotational. The wave is constructed as a superposition of two perpendicular, monochromatic standing Stokes waves and is standing-wave-like, but with ``antinodes'' or cells consisting of rotating surface gradients of alternating polarity. Lagrangian fluid particle trajectories show a rotational drift about each cell in the direction of wave rotation, corresponding to a rotating Stokes drift. Each cell therefore has a circulating flow and localized angular momentum even though the Eulerian flow is irrotational. Meanwhile, the wave sets up a static displacement of the free surface, making a trough in each cell. This static surface gradient provides a centripetal force that may account for additional rotation seen in experiments.

  12. Faraday rotation dispersion microscopy imaging of diamagnetic and chiral liquids with pulsed magnetic field.

    PubMed

    Suwa, Masayori; Nakano, Yusuke; Tsukahara, Satoshi; Watarai, Hitoshi

    2013-05-21

    We have constructed an experimental setup for Faraday rotation dispersion imaging and demonstrated the performance of a novel imaging principle. By using a pulsed magnetic field and a polarized light synchronized to the magnetic field, quantitative Faraday rotation images of diamagnetic organic liquids in glass capillaries were observed. Nonaromatic hydrocarbons, benzene derivatives, and naphthalene derivatives were clearly distinguished by the Faraday rotation images due to the difference in Verdet constants. From the wavelength dispersion of the Faraday rotation images in the visible region, it was found that the resonance wavelength in the UV region, which was estimated based on the Faraday B-term, could be used as characteristic parameters for the imaging of the liquids. Furthermore, simultaneous acquisition of Faraday rotation image and natural optical rotation image was demonstrated for chiral organic liquids.

  13. The 2D dynamics of radiative zones of low-mass stars

    NASA Astrophysics Data System (ADS)

    Hypolite, D.; Mathis, S.; Rieutord, M.

    2018-02-01

    Context. Helioseismology and asteroseismology allow us to probe the differential rotation deep within low-mass stars. In the solar convective envelope, the rotation varies with latitude with an equator rotating faster than the pole, which results in a shear applied on the radiative zone below. However, a polar acceleration of the convective envelope can be obtained through 3D numerical simulations in other low-mass stars and the dynamical interaction of the surface convective envelope with the radiative core needs to be investigated in the general case. Aim. In the context of secular evolution, we aim to describe the dynamics of the radiative core of low-mass stars to get a deeper understanding of the internal transport of angular momentum in such stars, which results in a solid rotation in the Sun from 0.7R⊙ to 0.2R⊙ and a weak radial core-envelope differential rotation in solar-type stars. This study requires at least a 2D description to capture the latitudinal variations of the differential rotation. Methods: We build 2D numerical models of a radiative core on the top of which we impose a latitudinal shear so as to reproduce a conical or cylindrical differential rotation in a convective envelope. We perform a systematic study over the Rossby number ℛo = ΔΩ/2Ω0 measuring the latitudinal differential rotation at the radiative-convective interface. We provide a 2D description of the differential rotation and the associated meridional circulation in the incompressible and stably stratified cases using the Boussinesq approximation. Results: The imposed shear generates a geostrophic flow implying a cylindrical differential rotation in the case of an isotropic viscosity. When compared to the baroclinic flow that arises from the stable stratification, we find that the geostrophic flow is dominant when the Rossby number is high enough (ℛo ≥ 1) with a cylindrical rotation profile. For low Rossby numbers (ℛo < 1), the baroclinic solution dominates with a quasi-shellular rotation profile. Using scaling laws from 3D simulations, we show that slow rotators (Ω0 < 30Ω⊙) are expected to have a cylindrical rotation profile. Fast rotators (Ω0 > 30Ω⊙) may have a shellular profile at the beginning of the main sequence in stellar radiative zones. Conclusions: This study enables us to predict different types of differential rotation and emphasizes the need for a new generation of 2D rotating stellar models developed in synergy with 3D numerical simulations. The shear induced by a surface convective zone has a strong impact on the dynamics of the underlying radiative zone in low-mass stars. However, it cannot produce a flat internal rotation profile in a solar configuration calling for additional processes for the transport of angular momentum in both radial and latitudinal directions.

  14. Job Rotation Designed to Prevent Musculoskeletal Disorders and Control Risk in Manufacturing Industries: A Systematic Review

    PubMed Central

    Padula, Rosimeire Simprini; Comper, Maria Luiza Caires; Sparer, Emily H.; Dennerlein, Jack T

    2017-01-01

    To better understand job rotation in the manufacturing industry, we completed a systematic review asking the following questions: 1) How do job-rotation programs impact work-related musculoskeletal disorders (MSDs) and related risk control for these MSDs, as well as psychosocial factors? and 2) How best should the job rotation programs be designed? We searched MEDLINE, EMBASE, Business Source Premier, ISI Web of Knowledge, CINAHL, PsyINFO, Scopus, and SciELO databases for articles published in peer-reviewed journals. Eligible studies were examined by two independent reviewers for relevance (population of manufacturing workers, outcomes of musculoskeletal disease, physical factors, psychosocial factors, and strategies used in job-rotation implantation) and methodological quality rating. From 10,809 potential articles, 71 were read for full text analysis. Of the 14 studies included for data extraction, two were non-randomized control trial studies, one was a case-control study, and 11 were cross-sectional comparisons. Only one, with a case-control design, was scored with good methodological quality. Currently, weak evidence exists supporting job rotation as a strategy for the prevention and control of musculoskeletal disorders. Job rotation did not appear to reduce the exposure of physical risk factors; yet, there are positive correlations between job rotation and higher job satisfaction. Worker training has been described as a crucial component of a successful job-rotation program. The studies reported a range of parameters used to implement and measure job-rotation programs. More rigorous studies are needed to better understand the full impact of job rotation on production and health. PMID:27633235

  15. Effect of Rotation on Scaffold Motion and Cell Growth in Rotating Bioreactors.

    PubMed

    Varley, Mark C; Markaki, Athina E; Brooks, Roger A

    2017-06-01

    Efficient use of different bioreactor designs to improve cell growth in three-dimensional scaffolds requires an understanding of their mechanism of action. To address this for rotating wall vessel bioreactors, fluid and scaffold motion were investigated experimentally at different rotation speeds and vessel fill volumes. Low cost bioreactors with single and dual axis rotation were developed to investigate the effect of these systems on human osteoblast proliferation in free floating and constrained collagen-glycosaminoglycan porous scaffolds. A range of scaffold motions (free fall, periodic oscillation, and orbital motion) were observed at the rotation speeds and vessel fluid/air ratios used, with 85% fluid fill and an outer vessel wall velocity of ∼14 mm s -1 producing a scaffold in a free fall state. The cell proliferation results showed that after 14 and 21 days of culture, this combination of fluid fill and speed of rotation produced significantly greater cell numbers in the scaffolds than when lower or higher rotation speeds (p < 0.002) or when the chamber was 60% or 100% full (p < 0.01). The fluid flow and scaffold motion experiments show that biaxial rotation would not improve the mass transfer of medium into the scaffold as the second axis of rotation can only transition the scaffold toward oscillatory or orbital motion and, hence, reduce mass transport to the scaffold. The cell culture results confirmed that there was no benefit to the second axis of rotation with no significant difference in cell proliferation either when the scaffolds were free floating or constrained (p > 0.05).

  16. Effect of Rotation on Scaffold Motion and Cell Growth in Rotating Bioreactors

    PubMed Central

    Varley, Mark C.; Markaki, Athina E.

    2017-01-01

    Efficient use of different bioreactor designs to improve cell growth in three-dimensional scaffolds requires an understanding of their mechanism of action. To address this for rotating wall vessel bioreactors, fluid and scaffold motion were investigated experimentally at different rotation speeds and vessel fill volumes. Low cost bioreactors with single and dual axis rotation were developed to investigate the effect of these systems on human osteoblast proliferation in free floating and constrained collagen-glycosaminoglycan porous scaffolds. A range of scaffold motions (free fall, periodic oscillation, and orbital motion) were observed at the rotation speeds and vessel fluid/air ratios used, with 85% fluid fill and an outer vessel wall velocity of ∼14 mm s−1 producing a scaffold in a free fall state. The cell proliferation results showed that after 14 and 21 days of culture, this combination of fluid fill and speed of rotation produced significantly greater cell numbers in the scaffolds than when lower or higher rotation speeds (p < 0.002) or when the chamber was 60% or 100% full (p < 0.01). The fluid flow and scaffold motion experiments show that biaxial rotation would not improve the mass transfer of medium into the scaffold as the second axis of rotation can only transition the scaffold toward oscillatory or orbital motion and, hence, reduce mass transport to the scaffold. The cell culture results confirmed that there was no benefit to the second axis of rotation with no significant difference in cell proliferation either when the scaffolds were free floating or constrained (p > 0.05). PMID:28125920

  17. Sex differences in mental rotation tasks: Not just in the mental rotation process!

    PubMed

    Boone, Alexander P; Hegarty, Mary

    2017-07-01

    The paper-and-pencil Mental Rotation Test (Vandenberg & Kuse, 1978) consistently produces large sex differences favoring men (Voyer, Voyer, & Bryden, 1995). In this task, participants select 2 of 4 answer choices that are rotations of a probe stimulus. Incorrect choices (i.e., foils) are either mirror reflections of the probe or structurally different. In contrast, in the mental rotation experimental task (Shepard & Metzler, 1971) participants judge whether 2 stimuli are the same but rotated or different by mirror reflection. The goal of the present research was to examine sources of sex differences in mental rotation, including the ability to capitalize on the availability of structure foils. In 2 experiments, both men and women had greater accuracy and faster reaction times (RTs) for structurally different compared with mirror foils in different versions of the Vandenberg and Kuse Mental Rotation Test (Experiment 1) and the Shepard and Metzler experimental task (Experiment 2). A significant male advantage in accuracy but not response time was found for both trial types. The male advantage was evident when all foils were structure foils so that mental rotation was not necessary (Experiment 3); however, when all foils were structure foils and participants were instructed to look for structure foils a significant sex difference was no longer evident (Experiment 4). Results suggest that the mental rotation process is not the only source of the sex difference in mental rotation tasks. Alternative strategy use is another source of sex differences in these tasks. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. Are Prior Experience and Subspecialty Training Time Predictive of Pediatric Anesthesia Exit Exam Scores for Rotating CA-2 Residents?

    PubMed

    Nelson, Jonathon H; Deutsch, Nina; Cohen, Ira T; Reddy, Srijaya K

    2017-01-01

    Anesthesiology residency programs commonly have rotations at free-standing children's hospitals to provide and/or supplement their residents' training in pediatric anesthesia. Length and timing of these rotations differ from program to program as can their residents' existing medical knowledge and clinical skills. We predicted that residents with prior pediatric anesthesia experience, who rotate at our pediatric institution for two consecutive months, will score higher on an exit exam compared to residents without prior pediatric experience or those that only rotate for one month. A 50-question multiple choice test was created using pediatric questions released from The American Board of Anesthesiology (ABA) written examinations. The test was administered and proctored at the end of each rotation. Study participants came from three different programs: Program A offers prior pediatric anesthesia experience and a one month rotation; Program B - offers prior pediatric anesthesia experience and a two month rotation; and Program C - does not offer prior pediatric anesthesia experience but includes a two month rotation. The 2014-2015 cohort consisted of 26 rotating second-year clinical anesthesia (CA-2) residents. One resident's exam scores were excluded from this study due to protocol violation. Mean exam scores for Program A, B, and C were 70.5% ± 5.7, 64.2% ± 7.0, and 67.3% ± 4.3, respectively. There was no statistically significant difference in the exit exam scores among the three groups. Prior pediatric anesthesia experience or length of time for subspecialty rotation was not associated with any significant difference in exit exam scores for CA-2 residents.

  19. Weight-bearing computed tomography findings in varus ankle osteoarthritis: abnormal internal rotation of the talus in the axial plane.

    PubMed

    Kim, Ji-Beom; Yi, Young; Kim, Jae-Young; Cho, Jae-Ho; Kwon, Min-Soo; Choi, Seung-Hyuk; Lee, Woo-Chun

    2017-08-01

    To assess the incidence of abnormal internal rotation of the talus in the axial plane in patients with varus ankle osteoarthritis, and to determine whether this incidence differs from the severity of varus ankle osteoarthritis (moderate versus severe). We retrospectively evaluated weight-bearing computed tomography (CT) and plain radiographs of 52 ankles with no abnormalities (control group) and 96 ankles with varus osteoarthritis (varus-OA group), which were further stratified into a moderate-OA subgroup (50 ankles) and a severe-OA subgroup (46 ankles). A new radiographic parameter on weight-bearing CT, the talus rotation ratio, was used to assess the rotation of the talus in the axial plane. The normal range of the talus rotation ratio was defined as the 95% prediction interval for talus rotation ratio values in the control group. Abnormal internal rotation of the talus was defined for talus rotation ratio values above the normal range. We determined the incidence of abnormal internal rotation of the talus in the varus-OA group, moderate-OA subgroup, and severe-OA subgroup. In the varus-OA group, the incidence of abnormal internal rotation of the talus was 45% (43 ankles), which corresponded to an incidence of 32% (16 ankles) in the moderate-OA subgroup and 59% (27 ankles) in the severe-OA subgroup (p = 0.013). Our study demonstrates that abnormal internal rotation of the talus occurs in patients with varus ankle osteoarthritis, and is more frequently noted in severe than in moderate varus ankle osteoarthritis.

  20. Heart Disease and Left Ventricular Rotation – A Systematic Review and Quantitative Summary

    PubMed Central

    2012-01-01

    Background Left ventricular (LV) rotation is increasingly examined in those with heart disease. The available evidence measuring LV rotation in those with heart diseases has not been systematically reviewed. Methods To review systematically the evidence measuring LV rotational changes in various heart diseases compared to healthy controls, literature searches were conducted for appropriate articles using several electronic databases (e.g., MEDLINE, EMBASE). All randomized-controlled trials, prospective cohort and case–controlled studies that assessed LV rotation in relation to various heart conditions were included. Three independent reviewers evaluated each investigation’s quality using validated scales. Results were tabulated and levels of evidence assigned. Results A total of 1,782 studies were found through the systematic literature search. Upon review of the articles, 47 were included. The articles were separated into those investigating changes in LV rotation in participants with: aortic stenosis, myocardial infarction, hypertrophic cardiomyopathy, dilated cardiomyopathy, non-compaction, restrictive cardiomyopathy/ constrictive pericarditis, heart failure, diastolic dysfunction, heart transplant, implanted pacemaker, coronary artery disease and cardiovascular disease risk factors. Evidence showing changes in LV rotation due to various types of heart disease was supported by evidence with limited to moderate methodological quality. Conclusions Despite a relatively low quality and volume of evidence, the literature consistently shows that heart disease leads to marked changes in LV rotation, while rotational systolic-diastolic coupling is preserved. No prognostic information exists on the potential value of rotational measures of LV function. The literature suggests that measures of LV rotation may aid in diagnosing subclinical aortic stenosis and diastolic dysfunction. PMID:22726250

  1. Differences between two subgroups of low back pain patients in lumbopelvic rotation and symmetry in the erector spinae and hamstring muscles during trunk flexion when standing.

    PubMed

    Kim, Min-hee; Yoo, Won-gyu; Choi, Bo-ram

    2013-04-01

    The present study was performed to examine lumbopelvic rotation and to identify asymmetry of the erector spinae and hamstring muscles in people with and without low back pain (LBP). The control group included 16 healthy subjects, the lumbar-flexion-rotation syndrome LBP group included 17 subjects, and the lumbar-extension-rotation syndrome LBP group included 14 subjects. Kinematic parameters were recorded using a 3D motion-capture system, and electromyography parameters were measured using a Noraxon TeleMyo 2400T. The two LBP subgroups showed significantly more lumbopelvic rotation during trunk flexion in standing than did the control group. The muscle activity and flexion-relaxation ratio asymmetries of the erector spinae muscles in the lumbar-flexion-rotation syndrome LBP group were significantly greater than those in the control group, and the muscle activity and flexion-relaxation ratio asymmetry of the hamstring muscles in the lumbar-extension-rotation syndrome LBP group were significantly greater than those in the control group. Imbalance or asymmetry of passive tissue could lead to asymmetry of muscular activation. Muscle imbalance can cause asymmetrical alignment or movements such as unexpected rotation. The results showed a greater increase in lumbopelvic rotation during trunk flexion in standing among the lumbar-flexion-rotation syndrome and lumbar-extension-rotation syndrome LBP groups compared with the control group. The differences between the two LBP subgroups may be a result of imbalance and asymmetry in erector spinae and hamstring muscle properties. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Arthroscopic undersurface rotator cuff repair versus conventional arthroscopic double-row rotator cuff repair - Comparable results at 2-year follow-up.

    PubMed

    Ang, Benjamin Fu Hong; Chen, Jerry Yongqiang; Yeo, William; Lie, Denny Tijauw Tjoen; Chang, Paul Chee Cheng

    2018-01-01

    The aim of our study is to compare the improvement in clinical outcomes after conventional arthroscopic double-row rotator cuff repair and arthroscopic undersurface rotator cuff repair. A consecutive series of 120 patients who underwent arthroscopic rotator cuff repair was analysed. Sixty-one patients underwent conventional double-row rotator cuff repair and 59 patients underwent undersurface rotator cuff repair. Several clinical outcomes, including numerical pain rating scale (NPRS), constant shoulder score (CSS), Oxford shoulder score (OSS) and University of California Los Angeles shoulder score (UCLASS), were prospectively recorded by a trained healthcare professional preoperatively and at 3, 6, 12 and 24 months after surgery. Comparing both groups, there were no differences in age, gender and preoperative NPRS, CSS, OSS and UCLASS. However, the tear size was 0.7 ± 0.2 (95% confidence interval (CI) 0.3-1.1) cm larger in the conventional group ( p = 0.002). There was no difference in the improvement of NPRS, CSS, OSS and UCLASS at all time points of follow-up, that is, at 3, 6, 12 and 24 months after surgery. The duration of operation was shorter by 35 ± 3 (95% CI 28-42) min in the undersurface group ( p < 0.001). Both arthroscopic undersurface rotator cuff repair and conventional arthroscopic double-row rotator cuff repair showed marked improvements in clinical scores when compared preoperatively, and there was no difference in improvements between both groups. Arthroscopic undersurface rotator cuff repair is a faster technique compared to the conventional arthroscopic double-row rotator cuff repair.

  3. Theoretical axial wall angulation for rotational resistance form in an experimental-fixed partial denture

    PubMed Central

    2017-01-01

    PURPOSE The aim of this study was to determine the influence of long base lengths of a fixed partial denture (FPD) to rotational resistance with variation of vertical wall angulation. MATERIALS AND METHODS Trigonometric calculations were done to determine the maximum wall angle needed to resist rotational displacement of an experimental-FPD model in 2-dimensional plane. The maximum wall angle calculation determines the greatest taper that resists rotation. Two different axes of rotation were used to test this model with five vertical abutment heights of 3-, 3.5-, 4-, 4.5-, and 5-mm. The two rotational axes were located on the mesial-side of the anterior abutment and the distal-side of the posterior abutment. Rotation of the FPD around the anterior axis was counter-clockwise, Posterior-Anterior (P-A) and clockwise, Anterior-Posterior (A-P) around the distal axis in the sagittal plane. RESULTS Low levels of vertical wall taper, ≤ 10-degrees, were needed to resist rotational displacement in all wall height categories; 2–to–6–degrees is generally considered ideal, with 7–to–10–degrees as favorable to the long axis of the abutment. Rotation around both axes demonstrated that two axial walls of the FPD resisted rotational displacement in each direction. In addition, uneven abutment height combinations required the lowest wall angulations to achieve resistance in this study. CONCLUSION The vertical height and angulation of FPD abutments, two rotational axes, and the long base lengths all play a role in FPD resistance form. PMID:28874995

  4. Errors of car wheels rotation rate measurement using roller follower on test benches

    NASA Astrophysics Data System (ADS)

    Potapov, A. S.; Svirbutovich, O. A.; Krivtsov, S. N.

    2018-03-01

    The article deals with rotation rate measurement errors, which depend on the motor vehicle rate, on the roller, test benches. Monitoring of the vehicle performance under operating conditions is performed on roller test benches. Roller test benches are not flawless. They have some drawbacks affecting the accuracy of vehicle performance monitoring. Increase in basic velocity of the vehicle requires increase in accuracy of wheel rotation rate monitoring. It determines the degree of accuracy of mode identification for a wheel of the tested vehicle. To ensure measurement accuracy for rotation velocity of rollers is not an issue. The problem arises when measuring rotation velocity of a car wheel. The higher the rotation velocity of the wheel is, the lower the accuracy of measurement is. At present, wheel rotation frequency monitoring on roller test benches is carried out by following-up systems. Their sensors are rollers following wheel rotation. The rollers of the system are not kinematically linked to supporting rollers of the test bench. The roller follower is forced against the wheels of the tested vehicle by means of a spring-lever mechanism. Experience of the test bench equipment operation has shown that measurement accuracy is satisfactory at small rates of vehicles diagnosed on roller test benches. With a rising diagnostics rate, rotation velocity measurement errors occur in both braking and pulling modes because a roller spins about a tire tread. The paper shows oscillograms of changes in wheel rotation velocity and rotation velocity measurement system’s signals when testing a vehicle on roller test benches at specified rates.

  5. Rotational elasticity

    NASA Astrophysics Data System (ADS)

    Vassiliev, Dmitri

    2017-04-01

    We consider an infinite three-dimensional elastic continuum whose material points experience no displacements, only rotations. This framework is a special case of the Cosserat theory of elasticity. Rotations of material points are described mathematically by attaching to each geometric point an orthonormal basis that gives a field of orthonormal bases called the coframe. As the dynamical variables (unknowns) of our theory, we choose the coframe and a density. We write down the general dynamic variational functional for our rotational theory of elasticity, assuming our material to be physically linear but the kinematic model geometrically nonlinear. Allowing geometric nonlinearity is natural when dealing with rotations because rotations in dimension three are inherently nonlinear (rotations about different axes do not commute) and because there is no reason to exclude from our study large rotations such as full turns. The main result of the talk is an explicit construction of a class of time-dependent solutions that we call plane wave solutions; these are travelling waves of rotations. The existence of such explicit closed-form solutions is a non-trivial fact given that our system of Euler-Lagrange equations is highly nonlinear. We also consider a special case of our rotational theory of elasticity which in the stationary setting (harmonic time dependence and arbitrary dependence on spatial coordinates) turns out to be equivalent to a pair of massless Dirac equations. The talk is based on the paper [1]. [1] C.G.Boehmer, R.J.Downes and D.Vassiliev, Rotational elasticity, Quarterly Journal of Mechanics and Applied Mathematics, 2011, vol. 64, p. 415-439. The paper is a heavily revised version of preprint https://arxiv.org/abs/1008.3833

  6. Inertial rotation measurement with atomic spins: From angular momentum conservation to quantum phase theory

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Yuan, H.; Tang, Z.; Quan, W.; Fang, J. C.

    2016-12-01

    Rotation measurement in an inertial frame is an important technology for modern advanced navigation systems and fundamental physics research. Inertial rotation measurement with atomic spin has demonstrated potential in both high-precision applications and small-volume low-cost devices. After rapid development in the last few decades, atomic spin gyroscopes are considered a promising competitor to current conventional gyroscopes—from rate-grade to strategic-grade applications. Although it has been more than a century since the discovery of the relationship between atomic spin and mechanical rotation by Einstein [Naturwissenschaften, 3(19) (1915)], research on the coupling between spin and rotation is still a focus point. The semi-classical Larmor precession model is usually adopted to describe atomic spin gyroscope measurement principles. More recently, the geometric phase theory has provided a different view of the rotation measurement mechanism via atomic spin. The theory has been used to describe a gyroscope based on the nuclear spin ensembles in diamond. A comprehensive understanding of inertial rotation measurement principles based on atomic spin would be helpful for future applications. This work reviews different atomic spin gyroscopes and their rotation measurement principles with a historical overlook. In addition, the spin-rotation coupling mechanism in the context of the quantum phase theory is presented. The geometric phase is assumed to be the origin of the measurable rotation signal from atomic spins. In conclusion, with a complete understanding of inertial rotation measurements using atomic spin and advances in techniques, wide application of high-performance atomic spin gyroscopes is expected in the near future.

  7. Reports on block rotations, fault domains and crustal deformation

    NASA Technical Reports Server (NTRS)

    Nur, Amos

    1990-01-01

    Studies of block rotations, fault domains and crustal deformation in the western United States, Israel, and China are discussed. Topics include a three-dimensional model of crustal fracture by distributed fault sets, distributed deformation and block rotation in 3D, stress field rotation, and multiple strike slip fault sets.

  8. Factor Rotation and Standard Errors in Exploratory Factor Analysis

    ERIC Educational Resources Information Center

    Zhang, Guangjian; Preacher, Kristopher J.

    2015-01-01

    In this article, we report a surprising phenomenon: Oblique CF-varimax and oblique CF-quartimax rotation produced similar point estimates for rotated factor loadings and factor correlations but different standard error estimates in an empirical example. Influences of factor rotation on asymptotic standard errors are investigated using a numerical…

  9. Long-term rotation history and previous crop effects on corn seedling health

    USDA-ARS?s Scientific Manuscript database

    Diverse rotations provide benefits to agroecosystems through changes in the soil environment. A long term experiment was established to study four different four-year rotation sequences in which the crop phase prior to corn was sampled. Soils from rotations ending with soybean, sunflower, corn and p...

  10. Rotations with Rodrigues' Vector

    ERIC Educational Resources Information Center

    Pina, E.

    2011-01-01

    The rotational dynamics was studied from the point of view of Rodrigues' vector. This vector is defined here by its connection with other forms of parametrization of the rotation matrix. The rotation matrix was expressed in terms of this vector. The angular velocity was computed using the components of Rodrigues' vector as coordinates. It appears…

  11. Structure and symmetry in coherent perfect polarization rotation

    NASA Astrophysics Data System (ADS)

    Crescimanno, Michael; Zhou, Chuanhong; Andrews, James H.; Baker, Michael A.

    2015-01-01

    Theoretical investigations of different routes to coherent perfect polarization rotation illustrate its phenomenological connection with coherent perfect absorption. Our study of systems with broken parity, layering, combined Faraday rotation and optical activity, or a rotator-loaded optical cavity highlights their similarity and suggests alternate approaches to improving and miniaturizing optical devices.

  12. Highly accurate calculation of rotating neutron stars

    NASA Astrophysics Data System (ADS)

    Ansorg, M.; Kleinwächter, A.; Meinel, R.

    2002-01-01

    A new spectral code for constructing general-relativistic models of rapidly rotating stars with an unprecedented accuracy is presented. As a first application, we reexamine uniformly rotating homogeneous stars and compare our results with those obtained by several previous codes. Moreover, representative relativistic examples corresponding to highly flattened rotating bodies are given.

  13. Controlling Data Collection to Support SAR Image Rotation

    DOEpatents

    Doerry, Armin W.; Cordaro, J. Thomas; Burns, Bryan L.

    2008-10-14

    A desired rotation of a synthetic aperture radar (SAR) image can be facilitated by adjusting a SAR data collection operation based on the desired rotation. The SAR data collected by the adjusted SAR data collection operation can be efficiently exploited to form therefrom a SAR image having the desired rotational orientation.

  14. Think Spatial: The Representation in Mental Rotation Is Nonvisual

    ERIC Educational Resources Information Center

    Liesefeld, Heinrich R.; Zimmer, Hubert D.

    2013-01-01

    For mental rotation, introspection, theories, and interpretations of experimental results imply a certain type of mental representation, namely, visual mental images. Characteristics of the rotated representation can be examined by measuring the influence of stimulus characteristics on rotational speed. If the amount of a given type of information…

  15. Sex Differences in the Mental Rotation of Chemistry Representations

    ERIC Educational Resources Information Center

    Stieff, Mike

    2013-01-01

    Mental-rotation ability modestly predicts chemistry achievement. As such, sex differences in mental-rotation ability have been implicated as a causal factor that can explain sex differences in chemistry achievement and degree attainment. Although there is a correlation between mental-rotation ability and chemistry achievement, laboratory and field…

  16. Hall effect in the presence of rotation

    NASA Astrophysics Data System (ADS)

    Zubkov, M. A.

    2018-02-01

    A rotating relativistic fermion system is considered. The consideration is based on the Dirac equation written in the laboratory (non-rotating) reference frame. Rotation in this approach gives rise to the effective magnetic and electric fields that act in the same way both on positive and negative electric charges. In the presence of external electric field in the given system the electric current appears orthogonal to both the electric field and the axis of rotation. The possible applications to the physics of quark-gluon plasma are discussed.

  17. Rotational joint assembly for the prosthetic leg

    NASA Technical Reports Server (NTRS)

    Owens, L. J.; Jones, W. C. (Inventor)

    1977-01-01

    A rotational joint assembly for a prosthetic leg has been devised, which enables an artificial foot to rotate slightly when a person is walking, running or turning. The prosthetic leg includes upper and lower tubular members with the rotational joint assembly interposed between them. The assembly includes a restrainer mechanism which consists of a pivotably mounted paddle element. This device applies limiting force to control the rotation of the foot and also restores torque to return the foot back to its initial position.

  18. Pediatric Oncology Branch - training- medical student rotations | Center for Cancer Research

    Cancer.gov

    Medical Student Rotations Select 4th-year medical students may be approved for a 4-week elective rotation at the Pediatric Oncology Branch. This rotation emphasizes the important connection between research and patient care in pediatric oncology. The student is supervised directly by the Branch’s attending physician and clinical fellows. Students attend daily in-patient and out-patient rounds and multiple weekly Branch conferences, and are expected to research relevant topics and present a 30-minute talk near the end of their rotation.

  19. Rotational Spectrum of 1,1-Difluoroethane: Internal Rotation Analysis and Structure

    NASA Astrophysics Data System (ADS)

    Villamanan, R. M.; Chen, W. D.; Wlodarczak, G.; Demaison, J.; Lesarri, A. G.; Lopez, J. C.; Alonso, J. L.

    1995-05-01

    The rotational spectrum of CH3CHF2 in its ground state was measured up to 653 GHz. Accurate rotational and centrifugal distortion constants were determined. The internal rotation splittings were analyzed using the internal axis method. An ab initio structure has been calculated and a near-equilibrium structure has been estimated using offsets derived empirically. This structure was compared to an experimental r0 structure. The four lowest excited states (including the methyl torsion) have also been assigned.

  20. Self-defrosting recuperative air-to-air heat exchanger

    DOEpatents

    Drake, R.L.

    1993-12-28

    A heat exchanger is described which includes a stationary spirally or concentrically wound heat exchanger core with rotating baffles on upper and lower ends thereof. The rotating baffles include rotating inlets and outlets which are in communication with respective fixed inlets and outlets via annuli. The rotation of the baffles causes a concurrent rotation of the temperature distribution within the stationary exchanger core, thereby preventing frost build-up in some applications and preventing the formation of hot spots in other applications. 3 figures.

  1. Space station rotational equations of motion

    NASA Technical Reports Server (NTRS)

    Rheinfurth, M. H.; Carroll, S. N.

    1985-01-01

    Dynamic equations of motion are developed which describe the rotational motion for a large space structure having rotating appendages. The presence of the appendages produce torque coupling terms which are dependent on the inertia properties of the appendages and the rotational rates for both the space structure and the appendages. These equations were formulated to incorporate into the Space Station Attitude Control and Stabilization Test Bed to accurately describe the influence rotating solar arrays and thermal radiators have on the dynamic behavior of the Space Station.

  2. Jeans instability of rotating magnetized dusty plasma

    NASA Astrophysics Data System (ADS)

    Sharma, S.; Sutar, D. L.; Kumar, V.; Pensia, R. K.

    2018-05-01

    It has been shown that rotation has to play a predominant important role in the formation of many astrophysical objects and the stability of molecular clouds. In this paper the theoretical investigation of the presence of rotation in the magnetized dusty plasma. The general dispersion relation is obtained normal mode analysis technique, and we found the Alfven mode is modified due to the presence of rotation and magnetic field. The graphical presentation shows that rotation and Alfven wave velocity have a stabilizing in the system.

  3. Cooling for a rotating anode X-ray tube

    DOEpatents

    Smither, Robert K.

    1998-01-01

    A method and apparatus for cooling a rotating anode X-ray tube. An electromagnetic motor is provided to rotate an X-ray anode with cooling passages in the anode. These cooling passages are coupled to a cooling structure located adjacent the electromagnetic motor. A liquid metal fills the passages of the cooling structure and electrical power is provided to the motor to rotate the anode and generate a rotating magnetic field which moves the liquid metal through the cooling passages and cooling structure.

  4. Gravity controlled anti-reverse rotation device

    DOEpatents

    Dickinson, Robert J.; Wetherill, Todd M.

    1983-01-01

    A gravity assisted anti-reverse rotation device for preventing reverse rotation of pumps and the like. A horizontally mounted pawl is disposed to mesh with a fixed ratchet preventing reverse rotation when the pawl is advanced into intercourse with the ratchet by a vertically mounted lever having a lumped mass. Gravitation action on the lumped mass urges the pawl into mesh with the ratchet, while centrifugal force on the lumped mass during forward, allowed rotation retracts the pawl away from the ratchet.

  5. On geodesics of the rotation group SO(3)

    NASA Astrophysics Data System (ADS)

    Novelia, Alyssa; O'Reilly, Oliver M.

    2015-11-01

    Geodesics on SO(3) are characterized by constant angular velocity motions and as great circles on a three-sphere. The former interpretation is widely used in optometry and the latter features in the interpolation of rotations in computer graphics. The simplicity of these two disparate interpretations belies the complexity of the corresponding rotations. Using a quaternion representation for a rotation, we present a simple proof of the equivalence of the aforementioned characterizations and a straightforward method to establish features of the corresponding rotations.

  6. Probing molecular potentials with an optical centrifuge.

    PubMed

    Milner, A A; Korobenko, A; Hepburn, J W; Milner, V

    2017-09-28

    We use an optical centrifuge to excite coherent rotational wave packets in N 2 O, OCS, and CS 2 molecules with rotational quantum numbers reaching up to J≈465, 690, and 1186, respectively. Time-resolved rotational spectroscopy at such ultra-high levels of rotational excitation can be used as a sensitive tool to probe the molecular potential energy surface at internuclear distances far from their equilibrium values. Significant bond stretching in the centrifuged molecules results in the growing period of the rotational revivals, which are experimentally detected using coherent Raman scattering. We measure the revival period as a function of the centrifuge-induced rotational frequency and compare it with the numerical calculations based on the known Morse-cosine potentials.

  7. Probing molecular potentials with an optical centrifuge

    NASA Astrophysics Data System (ADS)

    Milner, A. A.; Korobenko, A.; Hepburn, J. W.; Milner, V.

    2017-09-01

    We use an optical centrifuge to excite coherent rotational wave packets in N2O, OCS, and CS2 molecules with rotational quantum numbers reaching up to J ≈465 , 690, and 1186, respectively. Time-resolved rotational spectroscopy at such ultra-high levels of rotational excitation can be used as a sensitive tool to probe the molecular potential energy surface at internuclear distances far from their equilibrium values. Significant bond stretching in the centrifuged molecules results in the growing period of the rotational revivals, which are experimentally detected using coherent Raman scattering. We measure the revival period as a function of the centrifuge-induced rotational frequency and compare it with the numerical calculations based on the known Morse-cosine potentials.

  8. Theoretical prediction of a rotating magnon wave packet in ferromagnets.

    PubMed

    Matsumoto, Ryo; Murakami, Shuichi

    2011-05-13

    We theoretically show that the magnon wave packet has a rotational motion in two ways: a self-rotation and a motion along the boundary of the sample (edge current). They are similar to the cyclotron motion of electrons, but unlike electrons the magnons have no charge and the rotation is not due to the Lorentz force. These rotational motions are caused by the Berry phase in momentum space from the magnon band structure. Furthermore, the rotational motion of the magnon gives an additional correction term to the magnon Hall effect. We also discuss the Berry curvature effect in the classical limit of long-wavelength magnetostatic spin waves having macroscopic coherence length.

  9. Forced convection in vertical Bridgman configuration with the submerged heater

    NASA Astrophysics Data System (ADS)

    Meyer, S.; Ostrogorsky, A. G.

    1997-02-01

    Ga-doped Ge single crystals were grown in vertical Bridgman configuration, using the submerged heater method (SHM). When used without rotation, the submerged heater drastically reduces convection at the solid-liquid interface. When the submerged heater is set in to rotation or oscillatory rotation, it acts as a centrifugal viscous pump, inducing forced convection (radial-inward flow) along the interface. The flow produced by a rotation and oscillatory rotation of the submerged heater was visualized using a 1 : 1 scale model. The vigorous mixing produced by the oscillatory rotation creates a nearly perfectly stirred melt, and yields a uniform lateral distribution of the dopant. The crystals were free of unintentionally produced striae.

  10. Effect of weak rotation on large-scale circulation cessations in turbulent convection.

    PubMed

    Assaf, Michael; Angheluta, Luiza; Goldenfeld, Nigel

    2012-08-17

    We investigate the effect of weak rotation on the large-scale circulation (LSC) of turbulent Rayleigh-Bénard convection, using the theory for cessations in a low-dimensional stochastic model of the flow previously studied. We determine the cessation frequency of the LSC as a function of rotation, and calculate the statistics of the amplitude and azimuthal velocity fluctuations of the LSC as a function of the rotation rate for different Rayleigh numbers. Furthermore, we show that the tails of the reorientation PDF remain unchanged for rotating systems, while the distribution of the LSC amplitude and correspondingly the cessation frequency are strongly affected by rotation. Our results are in close agreement with experimental observations.

  11. A priori predictions of the rotational constants for HC13N, HC15N, C5O

    NASA Technical Reports Server (NTRS)

    DeFrees, D. J.; McLean, A. D.

    1989-01-01

    Ab initio molecular orbital theory is used to estimate the rotational constant for several carbon-chain molecules that are candidates for discovery in interstellar space. These estimated rotational constants can be used in laboratory or astronomical searches for the molecules. The rotational constant for HC13N is estimated to be 0.1073 +/- 0.0002 GHz and its dipole moment 5.4 D. The rotational constant for HC15N is estimated to be 0.0724 GHz, with a somewhat larger uncertainty. The rotational constant of C5O is estimated to be 1.360 +/- 2% GHz and its dipole moment 4.4. D.

  12. Giant optical rotation in a three-dimensional semiconductor chiral photonic crystal.

    PubMed

    Takahashi, S; Tandaechanurat, A; Igusa, R; Ota, Y; Tatebayashi, J; Iwamoto, S; Arakawa, Y

    2013-12-02

    Optical rotation is experimentally demonstrated in a semiconductor-based three-dimensional chiral photonic crystal (PhC) at a telecommunication wavelength. We design a rotationally-stacked woodpile PhC structure, where neighboring layers are rotated by 45° and four layers construct a single helical unit. The mirror-asymmetric PhC made from GaAs with sub-micron periodicity is fabricated by a micro-manipulation technique. The linearly polarized light incident on the structure undergoes optical rotation during transmission. The obtained results show good agreement with numerical simulations. The measurement demonstrates the largest optical rotation angle as large as ∼ 23° at 1.3 μm wavelength for a single helical unit.

  13. Biocentrifuge system capable of exchanging specimen cages while in operational mode

    NASA Technical Reports Server (NTRS)

    Belew, R. R. (Inventor)

    1981-01-01

    The centrifuge comprises a generally circular, rotatably mounted frame carrying a plurality of removable and replaceable cages for the animal specimens. Pairs of opposing cages may be removed from the frame while it is rotating by means of a cage exchanger which rotates concentrically within the centrifuge and the speed of which is controlled independently of the frame speed. An image rotator is provided for selective observation of the rotating animals. The system further includes a waste conveyor system, a food supply system, and a water supply system for each cage for creating a life sustaining environment so that the animals can live in the rotating centrifuge for extended periods.

  14. A homogeneous 2D deformation of geological interest: Rotation shear

    NASA Astrophysics Data System (ADS)

    Bastida, Fernando; Bobillo-Ares, Nilo C.; Aller, Jesús; Lisle, Richard J.

    2018-07-01

    We define a simple two-dimensional deformation called "rotation shear". It has one line of no finite longitudinal strain with invariant direction and another one that rotates with the deformation. An analysis of this deformation is carried out. Rotation shear superficially resembles simple shear but the analysis reveals that the two deformations have very different properties. In general, lines deformed by simple shear show a more complex deformation history and undergo greater longitudinal strain, i.e. are more extended, than lines deformed by rotation shear. Rotation shear is used to explain the development of geological structures such as kink bands, ideal similar folds, crenulation and crenulation cleavage and shear zones.

  15. How Should We Perform Rotational Atherectomy to an Angulated Calcified Lesion?

    PubMed

    Sakakura, Kenichi; Taniguchi, Yousuke; Matsumoto, Mitsunari; Wada, Hiroshi; Momomura, Shin-Ichi; Fujita, Hideo

    2016-05-25

    Rotational atherectomy to an angulated calcified lesion is always challenging. The risk of catastrophic complications such as a burr becoming stuck or vessel perforation is greater when the calcified lesion is angulated. We describe the case of an 83-year-old female suffering from unstable angina. Diagnostic coronary angiography revealed an angulated calcified lesion in the proximal segment of the right coronary artery. We performed rotational atherectomy to the lesion, but intentionally did not advance the rotational atherectomy burr beyond the top of the angulation. We controlled the rotational atherectomy burr and stopped it just before the top of the angulation to avoid complications. Following rotational atherectomy, balloon dilatation with a non-compliant balloon was performed, and drug-eluting stents were successfully deployed. In this manuscript, we provide a review of the literature on this topic, and discuss how rotational atherectomy to an angulated calcified lesion should be performed.

  16. Internal rotation in halogenated toluenes: Rotational spectrum of 2,3-difluorotoluene

    NASA Astrophysics Data System (ADS)

    Nair, K. P. Rajappan; Herbers, Sven; Grabow, Jens-Uwe; Lesarri, Alberto

    2018-07-01

    The microwave rotational spectrum of 2,3-difluorotoluene has been studied by pulsed supersonic jet using Fourier transform microwave spectroscopy. The tunneling splitting due to the methyl internal rotation in the ground torsional state could be unambiguously identified and the three-fold (V3) potential barrier hindering the internal rotation of the methyl top was determined as 2518.70(15) J/mol. The ground-state rotational parameters for the parent and seven 13C isotopic species in natural abundance were determined with high accuracy, including all quartic centrifugal distortion constants. The molecular structure was derived using the substitution (rs) method. From the rotational constants of the different isotopic species the rs structure as well as the r0 structure was determined. Supporting ab initio (MP2) and DFT (B3LYP) calculations provided comparative values for the potential barrier and molecular parameters.

  17. Polygons on a rotating fluid surface.

    PubMed

    Jansson, Thomas R N; Haspang, Martin P; Jensen, Kåre H; Hersen, Pascal; Bohr, Tomas

    2006-05-05

    We report a novel and spectacular instability of a fluid surface in a rotating system. In a flow driven by rotating the bottom plate of a partially filled, stationary cylindrical container, the shape of the free surface can spontaneously break the axial symmetry and assume the form of a polygon rotating rigidly with a speed different from that of the plate. With water, we have observed polygons with up to 6 corners. It has been known for many years that such flows are prone to symmetry breaking, but apparently the polygonal surface shapes have never been observed. The creation of rotating internal waves in a similar setup was observed for much lower rotation rates, where the free surface remains essentially flat [J. M. Lopez, J. Fluid Mech. 502, 99 (2004). We speculate that the instability is caused by the strong azimuthal shear due to the stationary walls and that it is triggered by minute wobbling of the rotating plate.

  18. Capacity for visual features in mental rotation

    PubMed Central

    Xu, Yangqing; Franconeri, Steven L.

    2015-01-01

    Although mental rotation is a core component of scientific reasoning, we still know little about its underlying mechanism. For instance - how much visual information can we rotate at once? Participants rotated a simple multi-part shape, requiring them to maintain attachments between features and moving parts. The capacity of this aspect of mental rotation was strikingly low – only one feature could remain attached to one part. Behavioral and eyetracking data showed that this single feature remained ‘glued’ via a singular focus of attention, typically on the object’s top. We argue that the architecture of the human visual system is not suited for keeping multiple features attached to multiple parts during mental rotation. Such measurement of the capacity limits may prove to be a critical step in dissecting the suite of visuospatial tools involved in mental rotation, leading to insights for improvement of pedagogy in science education contexts. PMID:26174781

  19. The Role of Platelet Rich Plasma (PRP) and Other Biologics for Rotator Cuff Repair.

    PubMed

    Greenspoon, Joshua A; Moulton, Samuel G; Millett, Peter J; Petri, Maximilian

    2016-01-01

    Surgical treatment of rotator cuff tears has consistently demonstrated good clinical and functional outcomes. However, in some cases, the rotator cuff fails to heal. While improvements in rotator cuff constructs and biomechanics have been made, the role of biologics to aid healing is currently being investigated. A selective literature search was performed and personal surgical experiences are reported. Biologic augmentation of rotator cuff repairs can for example be performed wtableith platelet-rich plasma (PRP) and mesenchymal stem cells (MSCs). Clinical results on PRP application have been controversial. Application of MSCs has shown promise in animal studies, but clinical data on its effectiveness is presently lacking. The role of Matrix Metalloproteinase (MMP) inhibitors is another interesting field for potential targeted drug therapy after rotator cuff repair. Large randomized clinical studies need to confirm the benefit of these approaches, in order to eventually lower retear rates and improve clinical outcomes after rotator cuff repair.

  20. Domains of pulsational instability of low-frequency modes in rotating upper main sequence stars

    NASA Astrophysics Data System (ADS)

    Szewczuk, Wojciech; Daszyńska-Daszkiewicz, Jadwiga

    2017-07-01

    We determine instability domains on the Hertzsprung-Russell diagram for rotating main sequence stars with masses of 2-20 M⊙. The effects of the Coriolis force are treated wihin the traditional approximation. High-order g modes with harmonic degrees ℓ up to 4 and mixed gravity-Rossby modes with |m| up to 4 are considered. We include the effects of rotation in wider instability strips for a given ℓ compared to the non-rotating case and in an extension of the pulsational instability to hotter and more massive models. We present results for a fixed value of the initial rotation velocity as well as for a fixed ratio of the angular rotation frequency to its critical value. Moreover, we check how the initial hydrogen abundance, metallicity, overshooting from the convective core and opacity affect the pulsational instability domains. The effect of rotation on the period spacing is also discussed.

  1. Sex and hemisphere differences when mentally rotating meaningful and meaningless stimuli.

    PubMed

    Rilea, Stacy L

    2008-05-01

    The purpose of the current study was to investigate the influence of stimulus type and sex on strategy use and hemispheric processing during the mental rotation task. Participants included 67 right-handed men and women who completed three mental rotation tasks, all presented bilaterally. Participants rotated human stick figures, alphanumeric stimuli, and a two-dimensional (2D) meaningless object. No hemispheric differences were observed when rotating human stick figures, suggesting that men and women may rely on the same strategy. A left hemisphere advantage was observed in women when rotating alphanumeric stimuli, suggesting they may be relying on a verbal strategy, whereas no hemispheric differences were observed for men. Finally, inconsistent with predictions, no hemisphere differences were observed when rotating two-dimensional objects. The findings from the current study suggest that both the meaningfulness and the type of stimulus presented may influence strategy use differently for men and women.

  2. Optically tunable Quincke rotation of a nanometer-thin oblate spheroid

    NASA Astrophysics Data System (ADS)

    Gu, Yu; Zeng, Haibo

    2017-08-01

    Ever since the discovery of Quincke rotation (spontaneous rotation of a particle in fluid under a dc electric field) more than 100 years ago [G. Quincke, Ann. Phys. (Leipzig) 295, 417 (1896), 10.1002/andp.18962951102], the strength of the dc field has been the only external parameter to actively tune the rotation speed. In this paper we theoretically propose an optically tunable Quincke rotor exploiting the photoconductivity of a semiconducting nanometer-thin oblate spheroid. A full analysis of the instability of the Quincke rotation reveals that, unlike a prolate spheroid, no bistability is possible in such a dynamical system. In addition, the required material property and the strength of the dc electric field needed to realize the rotation are also elucidated. It is also predicted that light can be used to tune the spinning speed or simply turn on and off the Quincke rotation very effectively.

  3. DC conductivity of a suspension of insulating particles with internal rotation

    NASA Astrophysics Data System (ADS)

    Pannacci, N.; Lemaire, E.; Lobry, L.

    2009-04-01

    We analyse the consequences of Quincke rotation on the conductivity of a suspension. Quincke rotation refers to the spontaneous rotation of insulating particles dispersed in a slightly conducting liquid and subject to a high DC electric field: above a critical field, each particle rotates continuously around itself with an axis pointing in any direction perpendicular to the DC field. When the suspension is subject to an electric field lower than the threshold one, the presence of insulating particles in the host liquid decreases the bulk conductivity since the particles form obstacles to ion migration. But for electric fields higher than the critical one, the particles rotate and facilitate ion migration: the effective conductivity of the suspension is increased. We provide a theoretical analysis of the impact of Quincke rotation on the apparent conductivity of a suspension and we present experimental results obtained with a suspension of PMMA particles dispersed in weakly conducting liquids.

  4. Lunar Rotation, Orientation and Science

    NASA Astrophysics Data System (ADS)

    Williams, J. G.; Ratcliff, J. T.; Boggs, D. H.

    2004-12-01

    The Moon is the most familiar example of the many satellites that exhibit synchronous rotation. For the Moon there is Lunar Laser Ranging measurements of tides and three-dimensional rotation variations plus supporting theoretical understanding of both effects. Compared to uniform rotation and precession the lunar rotational variations are up to 1 km, while tidal variations are about 0.1 m. Analysis of the lunar variations in pole direction and rotation about the pole gives moment of inertia differences, third-degree gravity harmonics, tidal Love number k2, tidal dissipation Q vs. frequency, dissipation at the fluid-core/solid-mantle boundary, and emerging evidence for an oblate boundary. The last two indicate a fluid core, but a solid inner core is not ruled out. Four retroreflectors provide very accurate positions on the Moon. The experience with the Moon is a starting point for exploring the tides, rotation and orientation of the other synchronous bodies of the solar system.

  5. Motor learning and consolidation: the case of visuomotor rotation.

    PubMed

    Krakauer, John W

    2009-01-01

    Adaptation to visuomotor rotation is a particular form of motor learning distinct from force-field adaptation, sequence learning, and skill learning. Nevertheless, study of adaptation to visuomotor rotation has yielded a number of findings and principles that are likely of general importance to procedural learning and memory. First, rotation learning is implicit and appears to proceed through reduction in a visual prediction error generated by a forward model, such implicit adaptation occurs even when it is in conflict with an explicit task goal. Second, rotation learning is subject to different forms of interference: retrograde, anterograde through aftereffects, and contextual blocking of retrieval. Third, opposite rotations can be recalled within a short time interval without interference if implicit contextual cues (effector change) rather than explicit cues (color change) are used. Fourth, rotation learning consolidates both over time and with increased initial training (saturation learning).

  6. The Effect of Improved Sub-Daily Earth Rotation Models on Global GPS Data Processing

    NASA Astrophysics Data System (ADS)

    Yoon, S.; Choi, K. K.

    2017-12-01

    Throughout the various International GNSS Service (IGS) products, strong periodic signals have been observed around the 14 day period. This signal is clearly visible in all IGS time-series such as those related to orbit ephemerides, Earth rotation parameters (ERP) and ground station coordinates. Recent studies show that errors in the sub-daily Earth rotation models are the main factors that induce such noise. Current IGS orbit processing standards adopted the IERS 2010 convention and its sub-daily Earth rotation model. Since the IERS convention had published, recent advances in the VLBI analysis have made contributions to update the sub-daily Earth rotation models. We have compared several proposed sub-daily Earth rotation models and show the effect of using those models on orbit ephemeris, Earth rotation parameters and ground station coordinates generated by the NGS global GPS data processing strategy.

  7. The effect of shift rotation on variations of cortisol, fatigue and sleep in sound engineers.

    PubMed

    Vangelova, Katia

    2008-10-01

    The aim was to study the effect of rotation direction on the time-of-day variations of cortisol, fatigue and sleep in sound engineers broadcasting in a life show. The salivary cortisol and ratings of stress, sleepiness and fatigue were followed at three hour intervals in 25 sound engineers: 13 working very fast forward-rotating shifts and 12 working very fast backward-rotating shifts. Cortisol was assessed with radioimmunological kits. The participants reported for stress symptoms and filled sleep diary. Cortisol retained the typical diurnal pattern. The rotation direction interacted with the shift significantly and as a result higher cortisol values during the morning and night shifts in the backward rotating group were found as well as worse quality of sleep. Higher salivary cortisol during morning and night shifts and worse quality of sleep in engineers working very fast backward-rotating shifts may be an indication for insufficient recovery.

  8. Improved turbulence models based on large eddy simulation of homogeneous, incompressible turbulent flows

    NASA Technical Reports Server (NTRS)

    Bardino, J.; Ferziger, J. H.; Reynolds, W. C.

    1983-01-01

    The physical bases of large eddy simulation and subgrid modeling are studied. A subgrid scale similarity model is developed that can account for system rotation. Large eddy simulations of homogeneous shear flows with system rotation were carried out. Apparently contradictory experimental results were explained. The main effect of rotation is to increase the transverse length scales in the rotation direction, and thereby decrease the rates of dissipation. Experimental results are shown to be affected by conditions at the turbulence producing grid, which make the initial states a function of the rotation rate. A two equation model is proposed that accounts for effects of rotation and shows good agreement with experimental results. In addition, a Reynolds stress model is developed that represents the turbulence structure of homogeneous shear flows very well and can account also for the effects of system rotation.

  9. Capacity for Visual Features in Mental Rotation.

    PubMed

    Xu, Yangqing; Franconeri, Steven L

    2015-08-01

    Although mental rotation is a core component of scientific reasoning, little is known about its underlying mechanisms. For instance, how much visual information can someone rotate at once? We asked participants to rotate a simple multipart shape, requiring them to maintain attachments between features and moving parts. The capacity of this aspect of mental rotation was strikingly low: Only one feature could remain attached to one part. Behavioral and eye-tracking data showed that this single feature remained "glued" via a singular focus of attention, typically on the object's top. We argue that the architecture of the human visual system is not suited for keeping multiple features attached to multiple parts during mental rotation. Such measurement of capacity limits may prove to be a critical step in dissecting the suite of visuospatial tools involved in mental rotation, leading to insights for improvement of pedagogy in science-education contexts. © The Author(s) 2015.

  10. Rotating reverse osmosis: a dynamic model for flux and rejection

    NASA Technical Reports Server (NTRS)

    Lee, S.; Lueptow, R. M.

    2001-01-01

    Reverse osmosis (RO) is a compact process for the removal of ionic and organic pollutants from contaminated water. However, flux decline and rejection deterioration due to concentration polarization and membrane fouling hinders the application of RO technology. In this study, a rotating cylindrical RO membrane is theoretically investigated as a novel method to reduce polarization and fouling. A dynamic model based on RO membrane transport incorporating concentration polarization is used to predict the performance of rotating RO system. Operating parameters such as rotational speed and transmembrane pressure play an important role in determining the flux and rejection in rotating RO. For a given geometry, a rotational speed sufficient to generate Taylor vortices in the annulus is essential to maintain high flux as well as high rejection. The flux and rejection were calculated for wide range of operating pressures and rotational speeds. c 2001 Elsevier Science B.V. All rights reserved.

  11. Immobilization in Neutral Rotation for a Glenohumeral Dislocation Using a Sling and Splint

    PubMed Central

    2008-01-01

    The purpose of this manuscript is to provide an expedient means of immobilizing a glenohumeral dislocation in neutral rotation. This technique for post-reduction immobilization of a glenohumeral dislocation is inexpensive and easy to fabricate. Anterior glenohumeral dislocations often involve an avulsion of the labrum from the glenoid rim. In contrast to immobilization in internal rotation, positioning the shoulder in 0-45° of external rotation approximates the labrum and glenoid rim. It is hypothesized that placing the shoulder in a more externally rotated position could allow for better healing and increased joint stability. This technique places the shoulder in neutral rotation, because 45° of external rotation is awkward and may interfere with certain activities of daily living. Structural aluminum malleable (SAM) splints are used as an alternative to a bolster sling. The SAM splints are lightweight, simply shaped, and easily stored. PMID:21509136

  12. Using record player demonstrations as analog models for geophysical fluids

    NASA Astrophysics Data System (ADS)

    Grannan, A. M.; Cheng, J. S.; Hawkins, E. K.; Ribeiro, A.; Aurnou, J. M.

    2015-12-01

    All celestial bodies, including stars, planets, satellites, and asteroids, rotate. The influence of rotation on the fluid layers in these bodies plays an important and diverse role, affecting many processes including oceanic and atmospheric circulation at the surface and magnetic field generation occurring in the interior. To better understand these large-scale processes, record players and containers of water are used as analog models to demonstrate the basic interplay between rotation and fluid motions. To contrast between rotating and non-rotating fluid motions, coffee creamer and food coloring are used as fluid tracers to provide a hands-on method of understanding the influence of rotation on the shapes of the planets, weather patterns, and the alignment of magnetic fields with rotational axes. Such simple demonstrations have been successfully employed for children in public outreach events and for adults in graduate level fluid dynamics courses.

  13. Surface dimpling on rotating work piece using rotation cutting tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhapkar, Rohit Arun; Larsen, Eric Richard

    A combined method of machining and applying a surface texture to a work piece and a tool assembly that is capable of machining and applying a surface texture to a work piece are disclosed. The disclosed method includes machining portions of an outer or inner surface of a work piece. The method also includes rotating the work piece in front of a rotating cutting tool and engaging the outer surface of the work piece with the rotating cutting tool to cut dimples in the outer surface of the work piece. The disclosed tool assembly includes a rotating cutting tool coupledmore » to an end of a rotational machining device, such as a lathe. The same tool assembly can be used to both machine the work piece and apply a surface texture to the work piece without unloading the work piece from the tool assembly.« less

  14. Closed Timelike Loops in Homogeneous Rotating Λ-dust Cosmologies

    NASA Astrophysics Data System (ADS)

    Lindsay, David

    2015-04-01

    We first describes what a ``rotating'' Λ-dust universe is in general relativity: basically, our universe plus a small amount of rotation. We then mention the Canonical example, the Gödel solution, which would add one rotation to our universe in about 200 billion years. Then we describe what we believe to be all known homogeneous rotating Λ-dust cosmologies. A plot of their characteristics shows that they cannot comprise all such solutions, though the literature claims (in several places) that all rotating solutions with a non-zero Λ term have been discovered. Our research has investigated these solutions for closed timelike loops (CTLs), i.e., time-machines, and concluded that exactly those with Λ < 0 possess CTLs. This observation calls into question the standard bias in GR that ``too much'' rotation leads to non-causal behavior; instead, it appears that a negative cosmological constant is the culprit.

  15. Object permanence in dogs: invisible displacement in a rotation task.

    PubMed

    Miller, Holly C; Gipson, Cassie D; Vaughan, Aubrey; Rayburn-Reeves, Rebecca; Zentall, Thomas R

    2009-02-01

    Dogs were tested for object permanence using an invisible displacement in which an object was hidden in one of two containers at either end of a beam and the beam was rotated. Consistent with earlier research, when the beam was rotated 180 degrees , the dogs failed to find the object. However, when the beam was rotated only 90 degrees , they were successful. Furthermore, when the dogs were led either 90 degrees or 180 degrees around the apparatus, they were also successful. In a control condition, when the dogs could not see the direction of the 90 degrees rotation, they failed to find the object. The results suggest that the 180 degrees rotation may produce an interfering context that can be reduced by rotating the apparatus only 90 degrees or by changing the dogs' perspective. Once the conflict is eliminated, dogs show evidence of object permanence that includes invisibly displaced objects.

  16. Off-vertical rotation produces conditioned taste aversion and suppressed drinking in mice

    NASA Technical Reports Server (NTRS)

    Fox, R. A.; Lauber, A. H.; Daunton, N. G.; Phillips, M.; Diaz, L.

    1984-01-01

    The effects of off-vertical rotation upon the intake of tap water immediately after rotation and upon conditioned taste aversion were assessed in mice with the tilt of the rotation axis varying from 5 to 20 deg from the earth-vertical. Conditioned taste aversion occurred in all mice that were rotated, but the intake of tap water was suppressed only in mice that were rotated at 15 or 20 deg of tilt. The greater suppression of tap-water intake and the stronger conditioned aversion in the mouse as the angle of tilt was increased in this experiment are consistent with predictions from similar experiments with human subjects, where motion sickness develops more rapidly as the angle of tilt is increased. It was suggested that off-vertical rotation may be a useful procedure for insuring experimental control over vestibular stimulation in animal studies of motion sickness.

  17. Rotational response of superconductors: Magnetorotational isomorphism and rotation-induced vortex lattice

    NASA Astrophysics Data System (ADS)

    Babaev, Egor; Svistunov, Boris

    2014-03-01

    The analysis of nonclassical rotational response of superfluids and superconductors was performed by Onsager [Onsager, Nuovo Cimento, Suppl. 6, 279 (1949), 10.1007/BF02780991] and London [Superfluids (Wiley, New York, 1950)] and crucially advanced by Feynman [Prog. Low Temp. Phys. 1, 17 (1955), 10.1016/S0079-6417(08)60077-3]. It was established that, in the thermodynamic limit, neutral superfluids rotate by forming—without any threshold—a vortex lattice. In contrast, the rotation of superconductors at angular frequency Ω—supported by uniform magnetic field BL∝Ω due to surface currents—is of the rigid-body type (London law). Here we show that, neglecting the centrifugal effects, the behavior of a rotating superconductor is identical to that of a superconductor placed in a uniform fictitious external magnetic field H ˜=-BL. In particular, the isomorphism immediately implies the existence of two critical rotational frequencies in type-2 superconductors.

  18. Tumbling asteroid rotation with the YORP torque and inelastic energy dissipation

    NASA Astrophysics Data System (ADS)

    Breiter, S.; Murawiecka, M.

    2015-05-01

    The Yarkovsky-O'Keefe-Radzievskii-Paddack (YORP) effect and rotational energy dissipation due to inelastic deformations are two key mechanisms affecting rotation of tumbling asteroids in long term. Each of the effects used to be discussed separately. We present the first results concerning a simulation of their joint action. Asteroids (3103) Eger and (99942) Apophis, as well as their scaled variants, are used as test bodies. Plugging in the dissipation destroys limit cycles of the pure YORP, but creates a new asymptotic state of stationary tumbling with a fixed rotation period. The present model does not contradict finding Eger in the principal axis rotation. For Apophis, the model suggests that its current rotation state should be relatively young. In general, the fraction of initial conditions leading to the principal axis rotation is too small, compared to the actual data. The model requires a stronger energy dissipation and weaker YORP components in the nutation angle and obliquity.

  19. Confidence mediates the sex difference in mental rotation performance.

    PubMed

    Estes, Zachary; Felker, Sydney

    2012-06-01

    On tasks that require the mental rotation of 3-dimensional figures, males typically exhibit higher accuracy than females. Using the most common measure of mental rotation (i.e., the Mental Rotations Test), we investigated whether individual variability in confidence mediates this sex difference in mental rotation performance. In each of four experiments, the sex difference was reliably elicited and eliminated by controlling or manipulating participants' confidence. Specifically, confidence predicted performance within and between sexes (Experiment 1), rendering confidence irrelevant to the task reliably eliminated the sex difference in performance (Experiments 2 and 3), and manipulating confidence significantly affected performance (Experiment 4). Thus, confidence mediates the sex difference in mental rotation performance and hence the sex difference appears to be a difference of performance rather than ability. Results are discussed in relation to other potential mediators and mechanisms, such as gender roles, sex stereotypes, spatial experience, rotation strategies, working memory, and spatial attention.

  20. Unstable domains of tearing and Kelvin-Helmholtz instabilities in a rotating cylindrical plasma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan, D. M.; Wei, L.; Wang, Z. X., E-mail: zxwang@dlut.edu.cn

    2014-09-15

    Effects of poloidal rotation profile on tearing and Kelvin-Helmholtz (KH) instabilities in a cylindrical plasma are investigated by using a reduced magnetohydrodynamic model. Since the poloidal rotation has different effects on the tearing and KH modes in different rotation regimes, four unstable domains are numerically identified, i.e., the destabilized tearing mode domain, stabilized tearing mode domain, stable-window domain, and unstable KH mode domain. It is also found that when the rotation layer is in the outer region of the rational surface, the stabilizing role of the rotation can be enhanced so significantly that the stable window domain is enlarged. Moreover,more » Alfvén resonances can be induced by the tearing and KH modes in such rotating plasmas. Radially wide profiles of current and vorticity perturbations can be formed when multiple current sheets on different resonance positions are coupled together.« less

  1. REVIEWS OF TOPICAL PROBLEMS: Motion of particles and photons in the gravitational field of a rotating body (In memory of Vladimir Afanas'evich Ruban)

    NASA Astrophysics Data System (ADS)

    Dymnikova, I. G.

    1986-03-01

    A study is made of the trajectories of free motion of test particles and photons in the Kerr metric, which describes the gravitational field of a rotating massive body. The trajectories are classified on the basis of the integrals of the motion, which have a clear physical meaning. The cases of a strong gravitational field in the neighborhood of a rotating black hole as well as the weak-field approximation describing the motion of particles in the gravitational field of a rotating star or galaxy are considered. The review includes bound states (orbits) in the field of a rotating mass, scattering and gravitational capture of particles and photons by a rotating black hole, trajectories of falling into a black hole, and the bending of light rays and the gravitational time delay of signals in the gravitational field of a rotating body.

  2. [Effects of Geometrical Dimensions and Material Properties on the Rotation Characteristics of Head].

    PubMed

    Chen, Yue; Cui, Shihai; Li, Haiyan; Ruan, Shijie

    2016-08-01

    The validated finite element head model(FEHM)of a 3-year-old child,a 6-year-old child and a 50 th percentile adult were used to investigate the effects of head dimension and material parameters of brain tissues on the head rotational responses based on experimental design.Results showed that the effects of head dimension and directions of rotation on the head rotational responses were not significant under the same rotational loading condition,and the same results appeared in the viscoelastic material parameters of brain tissues.However,the head rotational responses were most sensitive to the shear modulus(G)of brain tissues relative to decay constant(β)and bulk modulus(K).Therefore,the selection of material parameters of brain tissues is most important to the accuracy of simulation results,especially in the study of brain injury criterion under the rotational loading conditions.

  3. Computer Experience and Gender Differences in Undergraduate Mental Rotation Performance.

    ERIC Educational Resources Information Center

    De Lisi, Richard; Cammarano, Diane M.

    1996-01-01

    This study surveyed undergraduates (27 men, 83 women) to investigate gender differences in mental rotation. It compared pretesting on the Vandenberg Test of Mental Rotation (VTMR) and posttesting after two sessions of computer games. Men typically scored higher on pretest VTMR. After playing a game requiring mental rotation of figures, women…

  4. Effective Rotations: Action Effects Determine the Interplay of Mental and Manual Rotations

    ERIC Educational Resources Information Center

    Janczyk, Markus; Pfister, Roland; Crognale, Michael A.; Kunde, Wilfried

    2012-01-01

    The last decades have seen a growing interest in the impact of action on perception and other concurrent cognitive processes. One particularly interesting example is that manual rotation actions facilitate mental rotations in the same direction. The present study extends this research in two fundamental ways. First, Experiment 1 demonstrates that…

  5. Systems and assemblies for transferring high power laser energy through a rotating junction

    DOEpatents

    Norton, Ryan J.; McKay, Ryan P.; Fraze, Jason D.; Rinzler, Charles C.; Grubb, Daryl L.; Faircloth, Brian O.; Zediker, Mark S.

    2016-01-26

    There are provided high power laser devices and systems for transmitting a high power laser beam across a rotating assembly, including optical slip rings and optical rotational coupling assemblies. These devices can transmit the laser beam through the rotation zone in free space or within a fiber.

  6. Steady States of the Parametric Rotator and Pendulum

    ERIC Educational Resources Information Center

    Bouzas, Antonio O.

    2010-01-01

    We discuss several steady-state rotation and oscillation modes of the planar parametric rotator and pendulum with damping. We consider a general elliptic trajectory of the suspension point for both rotator and pendulum, for the latter at an arbitrary angle with gravity, with linear and circular trajectories as particular cases. We treat the…

  7. A Model Job Rotation Plan: A 10-Year Follow-up.

    ERIC Educational Resources Information Center

    Robinson, Daniel C.; Delbridge-Parker, Linda

    1991-01-01

    Describes model job rotation plan in a college student affairs division in which a staff member (intern) rotates among departments as a staff development opportunity. A 10-year follow-up evaluation underscored the success of the program. Concludes job rotation is not just learning experience, but it is also sharing experience. (Author/ABL)

  8. 14 CFR 125.177 - Control of engine rotation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Control of engine rotation. 125.177 Section... Requirements § 125.177 Control of engine rotation. (a) Except as provided in paragraph (b) of this section, each airplane must have a means of individually stopping and restarting the rotation of any engine in...

  9. 14 CFR 121.279 - Control of engine rotation.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Control of engine rotation. 121.279 Section... of engine rotation. (a) Except as provided in paragraph (b) of this section, each airplane must have a means of individually stopping and restarting the rotation of any engine in flight. (b) In the...

  10. Visualizing Compound Rotations with Virtual Reality

    ERIC Educational Resources Information Center

    Flanders, Megan; Kavanagh, Richard C.

    2013-01-01

    Mental rotations are among the most difficult of all spatial tasks to perform, and even those with high levels of spatial ability can struggle to visualize the result of compound rotations. This pilot study investigates the use of the virtual reality-based Rotation Tool, created using the Virtual Reality Modeling Language (VRML) together with…

  11. Motor Processes in Children's Mental Rotation

    ERIC Educational Resources Information Center

    Frick, Andrea; Daum, Moritz M.; Walser, Simone; Mast, Fred W.

    2009-01-01

    Previous studies with adult human participants revealed that motor activities can influence mental rotation of body parts and abstract shapes. In this study, we investigated the influence of a rotational hand movement on mental rotation performance from a developmental perspective. Children at the age of 5, 8, and 11 years and adults performed a…

  12. 14 CFR 125.177 - Control of engine rotation.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Control of engine rotation. 125.177 Section... Requirements § 125.177 Control of engine rotation. (a) Except as provided in paragraph (b) of this section... flight. (b) In the case of turbine engine installations, a means of stopping rotation need be provided...

  13. Children's Performance in Mental Rotation Tasks: Orientation-Free Features Flatten the Slope

    ERIC Educational Resources Information Center

    Perrucci, Vittore; Agnoli, Franca; Albiero, Paolo

    2008-01-01

    Studies of the development of mental rotation have yielded conflicting results, apparently because different mental rotation tasks draw on different cognitive abilities. Children may compare two stimuli at different orientations without mental rotation if the stimuli contain orientation-free features. Two groups of children (78 6-year-olds and 92…

  14. The Rigid Orthogonal Procrustes Rotation Problem

    ERIC Educational Resources Information Center

    ten Berge, Jos M. F.

    2006-01-01

    The problem of rotating a matrix orthogonally to a best least squares fit with another matrix of the same order has a closed-form solution based on a singular value decomposition. The optimal rotation matrix is not necessarily rigid, but may also involve a reflection. In some applications, only rigid rotations are permitted. Gower (1976) has…

  15. 14 CFR 121.279 - Control of engine rotation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Control of engine rotation. 121.279 Section... of engine rotation. (a) Except as provided in paragraph (b) of this section, each airplane must have a means of individually stopping and restarting the rotation of any engine in flight. (b) In the...

  16. 14 CFR 125.177 - Control of engine rotation.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Control of engine rotation. 125.177 Section... Requirements § 125.177 Control of engine rotation. (a) Except as provided in paragraph (b) of this section, each airplane must have a means of individually stopping and restarting the rotation of any engine in...

  17. 14 CFR 125.177 - Control of engine rotation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Control of engine rotation. 125.177 Section... Requirements § 125.177 Control of engine rotation. (a) Except as provided in paragraph (b) of this section, each airplane must have a means of individually stopping and restarting the rotation of any engine in...

  18. 14 CFR 125.177 - Control of engine rotation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Control of engine rotation. 125.177 Section... Requirements § 125.177 Control of engine rotation. (a) Except as provided in paragraph (b) of this section, each airplane must have a means of individually stopping and restarting the rotation of any engine in...

  19. 14 CFR 121.279 - Control of engine rotation.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Control of engine rotation. 121.279 Section... of engine rotation. (a) Except as provided in paragraph (b) of this section, each airplane must have a means of individually stopping and restarting the rotation of any engine in flight. (b) In the...

  20. 14 CFR 121.279 - Control of engine rotation.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Control of engine rotation. 121.279 Section... of engine rotation. (a) Except as provided in paragraph (b) of this section, each airplane must have a means of individually stopping and restarting the rotation of any engine in flight. (b) In the...

Top