  1. How Should We Perform Rotational Atherectomy to an Angulated Calcified Lesion?

    PubMed

    Sakakura, Kenichi; Taniguchi, Yousuke; Matsumoto, Mitsunari; Wada, Hiroshi; Momomura, Shin-Ichi; Fujita, Hideo

    2016-05-25

    Rotational atherectomy to an angulated calcified lesion is always challenging. The risk of catastrophic complications such as a burr becoming stuck or vessel perforation is greater when the calcified lesion is angulated. We describe the case of an 83-year-old female suffering from unstable angina. Diagnostic coronary angiography revealed an angulated calcified lesion in the proximal segment of the right coronary artery. We performed rotational atherectomy to the lesion, but intentionally did not advance the rotational atherectomy burr beyond the top of the angulation. We controlled the rotational atherectomy burr and stopped it just before the top of the angulation to avoid complications. Following rotational atherectomy, balloon dilatation with a non-compliant balloon was performed, and drug-eluting stents were successfully deployed. In this manuscript, we provide a review of the literature on this topic, and discuss how rotational atherectomy to an angulated calcified lesion should be performed.

  2. Current status of rotational atherectomy.

    PubMed

    Tomey, Matthew I; Kini, Annapoorna S; Sharma, Samin K

    2014-04-01

    Rotational atherectomy facilitates percutaneous coronary intervention for complex de novo lesions with severe calcification. A strategy of routine rotational atherectomy has not, however, conferred reduction in restenosis or major adverse cardiac events. As it is technically demanding, rotational atherectomy is also uncommon. At this 25-year anniversary since the introduction of rotational atherectomy, we sought to review the current state-of-the-art in rotational atherectomy technique, safety, and efficacy data in the modern era of drug-eluting stents, strategies to prevent and manage complications, including slow-flow/no-reflow and burr entrapment, and appropriate use in the context of the broader evolution in the management of stable ischemic heart disease. Fundamental elements of optimal technique include use of a single burr with burr-to-artery ratio of 0.5 to 0.6-rotational speed of 140,000 to 150,000 rpm, gradual burr advancement using a pecking motion, short ablation runs of 15 to 20 s, and avoidance of decelerations >5,000 rpm. Combined with meticulous technique, optimal antiplatelet therapy, vasodilators, flush solution, and provisional use of atropine, temporary pacing, vasopressors, and mechanical support may prevent slow-flow/no-reflow, which in contemporary series is reported in 0.0% to 2.6% of cases. On the basis of the results of recent large clinical trials, a subset of patients with complex coronary artery disease previously assigned to rotational atherectomy may be directed instead to medical therapy alone or bypass surgery. For patients with de novo severely calcified lesions for which rotational atherectomy remains appropriate, referral centers of excellence are required. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  3. Patient Selection and Procedural Considerations for Coronary Orbital Atherectomy System

    PubMed Central

    Sotomi, Yohei; Shlofmitz, Richard A; Colombo, Antonio; Serruys, Patrick W

    2016-01-01

    Despite advances in technology, percutaneous coronary intervention (PCI) of severely calcified coronary lesions remains challenging. Rotational atherectomy is one of the current therapeutic options to manage calcified lesions, but has a limited role in facilitating the dilation or stenting of lesions that cannot be crossed or expanded with other PCI techniques due to unfavourable clinical outcome in long-term follow-up. However the results of orbital atherectomy presented in the ORBIT I and ORBIT II trials were encouraging. In addition to these encouraging data, necessity for sufficient lesion preparation before implantation of bioresorbable scaffolds lead to resurgence in the use of atherectomy. This article summarises currently available publications on orbital atherectomy (Cardiovascular Systems Inc.) and compares them with rotational atherectomy. PMID:29588702

  4. Successful Expansion of an Underexpanded Stent by Rotational Atherectomy

    PubMed Central

    Vales, Lori; Coppola, John; Kwan, Tak

    2013-01-01

    The current routine use of intracoronary stents in percutaneous coronary intervention (PCI) has significantly reduced rates of restenosis, compared with balloon angioplasty alone. On the contrary, small post-stenting luminal dimensions due to undilatable, heavily calcified plaques have repeatedly been shown to significantly increase the rates of in-stent restenosis. Rotational atherectomy of lesions is an alternative method to facilitate PCI and prevent underexpansion of stents, when balloon angioplasty fails to successfully dilate a lesion. Stentablation, using rotational atherectomy to expand underexpanded stents deployed in heavily calcified plaques, has also been reported. We report a case via the transradial approach of rotational-atherectomy–facilitated PCI of in-stent restenosis of a severely underexpanded stent due to a heavily calcified plaque. We review the literature and suggest rotational atherectomy may have a role in treating a refractory, severely underexpanded stent caused by a heavily calcified plaque through various proposed mechanisms. PMID:24436587

  5. Complex coronary lesions and rotational atherectomy: one hospital’s experience*

    PubMed Central

    Jiang, Jun; Sun, Yong; Xiang, Mei-xiang; Dong, Liang; Liu, Xian-bao; Hu, Xin-yang; Feng, Yan; Wang, Jian-an

    2012-01-01

    Objective: To evaluate the safety and effectiveness of rotational atherectomy followed by drug eluting stent (DES) implantation in patients with complex coronary lesions. Methods: From August 2006 to August 2012, 253 consecutive patients with 289 lesions and who underwent rotational atherectomy in our center were enrolled in this study. Results: The overall procedure success rate was 98% with the cost of two (0.8%) coronary perforations, three (1.2%) dissections, five (2.0%) slow flows or no flows, three (1.2%) peri-procedure myocardial infarctions, and two (0.8%) in hospital deaths. During follow-up (mean three years), one (0.4%) patient died, two (0.8%) patients had acute myocardial infarction, 14 (5.5%) had restenosis, and target lesion revascularization occurred in eight patients (3.2%). Conclusions: Rotational atherectomy followed by DES implantation is a safe and effective technique for patients with complex coronary lesions, especially calcified and non-dilatable lesions. PMID:22843185

  6. Atherectomy for calcified coronary lesions: When and how?

    PubMed

    Karatasakis, Aris; Brilakis, Emmanouil S

    2016-03-01

    Percutaneous coronary intervention of heavily calcified lesions can be challenging. Although the ROTAXUS trial did not demonstrate long-term clinical benefit with routine rotational atherectomy, atherectomy remains an indispensable tool to achieve acute procedural success. Until new data becomes available determining when and how to optimally use coronary atherectomy depends heavily on personal experience and clinical judgment. © 2016 Wiley Periodicals, Inc.

  7. A polymer driveshaft for use in orbital and rotational atherectomy

    NASA Astrophysics Data System (ADS)

    Grothe, Preston Lee

    Driveshafts used in atherectomy medical devices are often comprised of coiled or braided metal wires. These constructions are designed to tolerate delivery through tortuous vessels and can endure high speed rotation used during activation of the atherectomy treatment. This research investigated polymer driveshaft designs, which were comprised of polymer inner and outer layers, and coiled or braided stainless steel wires. The polymer driveshaft materials included polyimide, nylon 12, and polytetrafluoroethylene (PTFE). Mechanical testing of polymer driveshafts was conducted to determine material response in bending, tension, compression, and torsion. The polymer driveshaft test results were then compared with current coiled metal wire driveshaft constructions. The investigation identified polymer driveshaft options that could feasibly work in an atherectomy application.

  8. Promotion of artery occlusion in dogs by percutaneous rotational atherectomy.

    PubMed

    Hou, Chuan-Ju; Zhang, Duan-Zhen; Wang, Qi-Guang; Cui, Chun-Sheng; Kuang, Li; Chen, Bing; Wang, Yang

    2014-07-01

    This study aims to offer experimental data and indirect evidences for the application of percutaneous rotational atherectomy to treat patent ductus arteriosus (PDA). Eleven dogs (6 male dogs and 5 female dogs; aged 14-20 months, with an average of 16.7±3.2 months; weight 20-25 kg, with an average of 22.7±2.5 kg) were enrolled in this study. The diameters of the left and right arteries ranged from 3.2 to 4.8 mm (average 3.9±0.6 mm) on percutaneous angiography. Percutaneous rotational atherectomy with proper rotablator (the size was 1-1.5 mm larger than the artery diameter) was performed in the arterial intima. After 4 weeks from percutaneous rotational atherectomy, arteriography was conducted to observe the changes in artery diameter. Then all dogs were sacrificed and the pathologic examination was conducted on the left and right axillary arteries. There were obvious changes with different degrees in 22 arteries, including 8 arteries with complete occlusion and 12 arteries with stenosis (≥2/3, 1/2, and 1/3 stenosis in 4, 4, and 4 arteries, respectively). The occlusion rate was 36.4% and the total effective rate was 90.9%. It was considered failure in other 2 arteries with <1/3 of stenosis. Percutaneous rotational atherectomy of arterial intima can promote the occlusion of arteries. This has provided a new choice for the treatment of PDA. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. A critical view of the peripheral atherectomy data in the treatment of infrainguinal arterial disease.

    PubMed

    Quevedo, Henry C; Arain, Salman A; Ali, Gholam; Abi Rafeh, Nidal

    2014-01-01

    Revascularization of the peripheral arteries remains technically challenging. By decreasing the volume of the atherosclerotic plaque, debulking procedures may confer superior primary patency after revascularization. To assess the impact of atherectomy on primary patency rates at 12 months compared to balloon angioplasty and/or stent placement alone in patients with infrainguinal arterial disease. A database search for "directional," "orbital," "rotational," and "laser atherectomy" in peripheral arterial disease (PAD) was performed. Studies were screened according to the STROBE (Strengthening the Reporting of Observational studies in Epidemiology) critical appraisal tool and summarized by population, methodology, and outcomes (primary patency and major adverse events). Only two randomized studies were found. Most of the data were obtained from single-arm studies and registries. The primary patency with directional atherectomy approaches 60% at 12 months as a stand-alone technique, whereas orbital atherectomy in conjunction with balloon angioplasty and stenting achieved primary patency rates of 90%. Laser atherectomy is universally employed with balloon angioplasty and stenting for in-stent restenosis lesions with a primary patency rate of 64%. Although there are data for the safe use of rotational atherectomy, robust data to support its effectiveness are lacking. The combination of drug-coated balloons and atherectomy for the treatment of heavily calcified lesions in patients with critical limb ischemia is under evaluation. Despite the successful procedural outcomes reported in clinical registries, the available data do not support the use of atherectomy alone in PAD. Larger randomized controlled studies are warranted to define its role in contemporary endovascular practice.

  10. Atherectomy in complex infrainguinal lesions: a review.

    PubMed

    Engelberger, S; van den Berg, J C

    2015-02-01

    In the femoropopliteal segment, endovascular revascularization techniques have gained the role as a first line treatment strategy. Nitinol stent placement has improved the short- and mid-term primary patency rates in most lesion types and is therefore widely applied. Stenting has several shortcomings as in-stent restenosis, stent fractures and foreign material being left behind in the vessel. The concept of atherectomy is plaque debulking. This results in a potential reduction of inflation pressure requirements in angioplasty. Stent placement and consecutive in-stent restenosis may be avoided. In this non systematic literature review, the performance of different atherectomy techniques, such as direct atherectomy, orbital atherectomy, laser debulking and rotational atherectomy in the treatment of complex femoropopliteal lesions, including long lesions, moderately to heavily calcified lesions as well as occlusions and in-stent restenosis, has been analyzed.

  11. Two-Year Clinical Outcomes of Newer-Generation Drug-Eluting Stent Implantation Following Rotational Atherectomy for Heavily Calcified Lesions.

    PubMed

    Jinnouchi, Hiroyuki; Kuramitsu, Shoichi; Shinozaki, Tomohiro; Kobayashi, Yohei; Hiromasa, Takashi; Morinaga, Takashi; Mazaki, Toru; Sakakura, Kenichi; Soga, Yoshimitsu; Hyodo, Makoto; Shirai, Shinichi; Ando, Kenji

    2015-01-01

    Clinical outcomes of implantation of the newer-generation drug-eluting stent (DES) following rotational atherectomy for heavily calcified lesions remain unclear in the real-world setting. We enrolled 252 consecutive patients (273 lesions) treated with newer-generation DES following rotational atherectomy. The primary endpoint was the cumulative 2-year incidence of major adverse cardiovascular events (MACE), defined as cardiac death, myocardial infarction, clinically-driven target lesion revascularization, and definite stent thrombosis. Complete clinical follow-up information at 2-year was obtained for all patients. The mean age was 73.2±9.0 years and 155 patients (61.5%) were male. Cumulative 2-year incidence of MACE (cardiac death, myocardial infarction, clinically-driven target lesion revascularization and definite stent thrombosis) was 20.3% (7.0%, 2.1%, 18.1% and 2.1%, respectively). Predictors of MACE were presenting with acute coronary syndrome (hazard ratio [HR]: 3.80, 95% confidence interval [CI]: 1.29-11.2, P=0.02), hemodialysis (HR: 1.93, 95% CI: 1.04-3.56, P=0.04) and previous coronary artery bypass graft (HR: 2.26, 95% CI: 1.02-5.00, P=0.045). PCI for calcified lesions requiring rotational atherectomy is still challenging even in the era of newer-generation DES.

  12. Mechanism of lumen gain with a novel rotational aspiration atherectomy system for peripheral arterial disease: examination by intravascular ultrasound.

    PubMed

    Hassan, Ali H M; Ako, Junya; Waseda, Katsuhisa; Honda, Yasuhiro; Zeller, Thomas; Leon, Martin B; Fitzgerald, Peter J

    2010-01-01

    The purpose of this study was to evaluate the mechanism of luminal gain with a novel atheroablation system (Pathway PV) for the treatment of peripheral artery disease using intravascular ultrasound (IVUS). The atherectomy system is a rotational atherectomy device, which employs expandable rotating blades with ports that allow flushing and aspiration of the plaque material or thrombus. In this first-in-man clinical study, IVUS analysis was available in 6 patients with lower limb ischemia treated with this device. The treatment results were assessed using IVUS at pre and post atherectomy. Lumen beyond burr size (LBB) was defined as lumen gain divided by the estimated burr area determined by the burr-size. IVUS analysis was available in six patients (superficial femoral artery n=3, popliteal artery n=2, posterior tibial artery n=1). Atheroablation achieved a significant increase in lumen area (LA) (preintervention 3.9+/-0.4, postatheroablation 8.0+/-1.7 mm(2), P<.05), and significant reduction in plaque area (27.5+/-4.0, 23.7+/-3.1 mm(2), P=.001), while there was no change in the vessel area (31.3+/-4.2, 32.1+/-2.8 mm(2), P=.4). LBB was 57.4+/-51.3%. This novel rotational aspiration atherectomy device achieved significant luminal gain by debulking in the absence of vessel stretching. The LA was greater than burr-sized lumen expectancy at cross-sections along the treated segments, suggesting a complimentary role of aspiration in luminal gain in atherosclerotic peripheral artery lesions.

  13. Safety and efficacy of rotational atherectomy for the treatment of undilatable underexpanded stents implanted in calcific lesions.

    PubMed

    Ferri, Luca A; Jabbour, Richard J; Giannini, Francesco; Benincasa, Susanna; Ancona, Marco; Regazzoli, Damiano; Mangieri, Antonio; Montorfano, Matteo; Colombo, Antonio; Latib, Azeem

    2017-08-01

    Coronary stent underexpansion is a known risk factor for in-stent restenosis and stent thrombosis. There are limited options once noncompliant balloons have failed to achieve optimal stent expansion. Excimer Laser Coronary Angioplasty with contrast medium injection is one possibility, but not readily available. Rotational atherectomy is an alternative, and has been described in case reports, but concerns exist regarding safety. All consecutive patients undergoing rotational atherectomy for symptomatic in-stent restenosis due to stent underexpansion resistant to noncompliant balloon postdilatation between January 2005 and December 2015 were analysed. A total of 16 patients underwent treatment during the study period and the procedure was successful in 14 cases (87.5%). The mean postprocedural minimal lumen diameter increased by 2.3 ± 0.8 mm and percentage diameter stenosis decreased from 82.17% ± 17.2% to 11.9% ± 9.1%. Intraprocedural complications occurred in two patients (burr entrapment successfully managed percutaneously and periprocedural myocardial infarction). At 1-year follow-up, the incidence of target lesion revascularisation was 13.3% (2 out of 15 patients), and one patient died from noncardiac death. In this small series of underexpanded stents, rotational atherectomy was an effective treatment for resistant stent underexpansion with acceptable outcomes. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Experimental investigation of the abrasive crown dynamics in orbital atherectomy.

    PubMed

    Zheng, Yihao; Belmont, Barry; Shih, Albert J

    2016-07-01

    Orbital atherectomy is a catheter-based minimally invasive procedure to modify the plaque within atherosclerotic arteries using a diamond abrasive crown. This study was designed to investigate the crown motion and its corresponding contact force with the vessel. To this end, a transparent arterial tissue-mimicking phantom made of polyvinyl chloride was developed, a high-speed camera and image processing technique were utilized to visualize and quantitatively analyze the crown motion in the vessel phantom, and a piezoelectric dynamometer measured the forces on the phantom during the procedure. Observed under typical orbital atherectomy rotational speeds of 60,000, 90,000, and 120,000rpm in a 4.8mm caliber vessel phantom, the crown motion was a combination of high-frequency rotation at 1000, 1500, and 1660.4-1866.1Hz and low-frequency orbiting at 18, 38, and 40Hz, respectively. The measured forces were also composed of these high and low frequencies, matching well with the rotation of the eccentric crown and the associated orbital motion. The average peak force ranged from 0.1 to 0.4N at different rotational speeds. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. Contemporary clinical outcomes of patients treated with or without rotational coronary atherectomy--an analysis of the UK central cardiac audit database.

    PubMed

    Cockburn, James; Hildick-Smith, David; Cotton, James; Doshi, Sagar; Hanratty, Colm; Ludman, Peter; Robinson, Derek; Redwood, Simon; de Belder, Mark; de Belder, Adam

    2014-01-01

    Rotational atherectomy (RA) is widely used for treating calcified coronary lesions. Clinical data however remain limited. We assessed outcome and survival among patients undergoing percutaneous coronary intervention (PCI) with or without RA in the UK between September 2007 and March 2011. Data from 221,669 percutaneous coronary intervention (PCI) procedures were analysed; 2152 patients (0.97%) underwent RA (RA+); the remainder underwent conventional PCI (RA-). RA+ patients were older (71.7±9.6 vs. 64.1±12.8 year; p<0.001), and had a higher incidence of diabetes (26.4% vs. 18.0%; p<0.001), hypertension, (61.9% vs. 49.4%; p<0.001), peripheral vascular disease (9.9% vs. 4.2%, p<0.001), cerebrovascular disease (5.5% vs. 3.4%, p<0.001), renal impairment (3.4% vs. 1.5%, p<0.001) and poor left ventricular function (11.4% vs. 4.3%,p<0.001). Procedural success was lower among RA+ patients (90.3% vs 94.6%; p<0.001) and procedural complications were more frequent (9.7% vs 5.4%; p<0.001). After 2.4±1.2 years follow-up, unadjusted Cox proportional hazard modeling demonstrated poorer survival for RA+ patients (HR 2.21, 95%CI 1.97-2.49; p<0.0001). This disadvantage remained after adjustment for adverse variables (HR 1.26, 95%CI 1.11-1.44; p=0.0004) and following propensity analysis. There was evidence however of improved survival for RA+ patients with left main stem disease (HR 0.52, 95%CI 0.35-0.75, p<0.0001), and peripheral vascular disease (HR 0.65, 95%CI 0.43-0.98, p<0.0005). Rotational atherectomy was undertaken in patients with higher pre-procedural risk. Medium term survival was worse among patients undergoing rotational atherectomy, and this survival disadvantage remained after correction for available adverse factors. Rotational atherectomy however remains clinically useful for patients with calcified coronary lesions. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  16. Orbital atherectomy for severely calcified lesions: More dissections in women but similar 30-day outcomes to men.

    PubMed

    Chandrasekhar, Jaya; Mehran, Roxana

    2016-03-01

    Calcified lesions are associated with lower rates of successful percutaneous coronary intervention (PCI), greater stent thrombosis, and increased target vessel revascularization. Women undergoing PCI are more often older than men and likely to present with severe lesion calcification. The ORBIT II study, for the first time compares the effect of the orbital atherectomy system (OAS) in men and women undergoing PCI for severely calcified lesions. Although the adjusted risk of severe dissections was higher in women, the incidence of in-hospital and 30-day outcomes was similar to men. Randomized comparisons of the OAS with rotational atherectomy and with stenting without atherectomy are needed to further elucidate sex-based differences in calcified lesion PCI. © 2016 Wiley Periodicals, Inc.

  17. Clinical outcomes of atherectomy prior to percutaneous coronary intervention: A comparison of outcomes following rotational versus orbital atherectomy (COAP-PCI study).

    PubMed

    Meraj, Perwaiz M; Shlofmitz, Evan; Kaplan, Barry; Jauhar, Rajiv; Doshi, Rajkumar

    2018-04-29

    Because of the challenges in treating calcified coronary artery disease (CAD), lesion preparation has become increasingly important prior to percutaneous coronary intervention (PCI). Despite growing data for both rotational atherectomy (RA) and orbital atherectomy (OA), there have been no multicenter studies comparing the safety and efficacy of both. We sought to examine the clinical outcomes of patients with calcified CAD who underwent atherectomy. A total of 39 870 patients from five tertiary care hospitals who had PCI from January 2011 to January 2017 were identified. 907 patients who had RA or OA were included. This multicenter, prospectively collected observational analysis compared OA and RA. The primary end-point was myocardial infarction and safety outcomes including significant dissection, perforation, cardiac tamponade, and vascular complications. Propensity score matching (1:1) was performed to reduce selection bias. After matching, 546 patients were included in the final analysis. The primary endpoint, myocardial infarction occurred less frequently with OA compared to RA (6.7% vs 13.8%, P ≤ 0.01) in propensity score matched cohorts. Procedural safety outcomes were comparable between the groups. The secondary outcome of death on discharge occurred less in the OA group as compared with RA (0% vs 2.2%, P = 0.01). Fluoroscopy time was less in patients who were treated with OA (21.9 vs 25.6 min, P ≤ 0.01). Additional secondary outcomes were comparable between groups. In this non-randomized, multicenter comparison of contemporary atherectomy devices, OA was associated with significantly decreased in-hospital myocardial infarction and mortality after propensity score matching with decreased fluoroscopy time. © 2018, Wiley Periodicals, Inc.

  18. Application of rotational atherectomy in the drug-eluting stent era

    PubMed Central

    Chen, Chun-Chi; Hsieh, I-Chang

    2013-01-01

    Rotational atherectomy (RA) was introduced in the interventional arena in 1988 as a dedicated device for calcified lesions. Due to the complexity of the technique, the development of alternative methods such as the cutting balloon procedure, and the high restenosis rate of subsequent bare metal stenting in long lesions, its use had later declined. However, with the increasing use of drug-eluting stents (DES) and the aggressive treatment of longer lesions, the number of procedure performed with RA has increased significantly again in recent years. In this article, we reviewed the application of RA in DES era. PMID:24133506

  19. JETSTREAM Atherectomy: A Review of Technique, Tips, and Tricks in Treating the Femoropopliteal Lesions

    PubMed Central

    Shammas, Nicolas W.

    2014-01-01

    JETSTREAM (Bayer, Whippany, NJ) atherectomy is a highly effective rotational atherectomy device with active aspiration capacity approved in the United States to treat infrainguinal obstructive peripheral arterial disease. The technique in using the JETSTREAM is critical and relies on appropriate wire use, appropriate sizing, and speed in advancing the cutter as well as the use of fluoroscopic imaging and tactile and auditory senses. Using the right technique, the device appears to have a low rate of distal embolization and complications and results in high procedural success. We describe our own experience with the JETSTREAM device and the techniques used in our endovascular laboratory. PMID:26060377

  20. Morphological differences in coronary arteries following rotational atherectomy versus balloon angioplasty: ultrasound and angioscopic observations

    NASA Astrophysics Data System (ADS)

    Bass, Theodore A.; Gilmore, Paul S.; White, Christopher J.; Chami, Youssef G.; Kircher, Barbara J.; Conetta, Donald A.

    1993-09-01

    Percutaneous transluminal coronary rotational atherectomy (PTCRA) is an exciting new device to recannulate obstructed coronary arteries. This device works as a high speed `drill,' selectively cutting hard atherosclerotic plaque while preferentially sparing the softer, less diseased vascular luminal surface. At speeds as high as 200,000 rpm the plaque is pulverized into small particles easily handled by the circulatory system with no untoward clinical sequela. Balloon angioplasty does not remove atherosclerotic plaque. It dilates the vessel by mechanically stretching, compressing and splitting the plaque and vessel lining. We compare morphological and surface luminal characteristics of vessels post PTCRA to vessels post PTCA.

  1. Debulking Atherectomy in the Peripheral Arteries: Is There a Role and What is the Evidence?

    PubMed

    Katsanos, Konstantinos; Spiliopoulos, Stavros; Reppas, Lazaros; Karnabatidis, Dimitris

    2017-07-01

    Traditional percutaneous balloon angioplasty and stent placement is based on mechanical plaque disruption and displacement within the arterial wall. On the contrary, transcatheter atherectomy achieves atherosclerotic plaque clearance by means of directional plaque excision or rotational plaque removal or laser plaque ablation. Debulking atherectomy may allow for a more uniform angioplasty result at lower pressures with consequently less vessel barotrauma and improved luminal gain, thereby decreasing the risk of plaque recoil and dissection that may require permanent metal stenting. It has been also argued that atherectomy may disrupt the calcium barrier and optimize drug transfer and delivery in case of drug-coated balloon applications. The authors discuss the various types of atherectomy devices available in clinical practice to date and critically appraise their mode of action as well as relevant published data in each case. Overall, amassed randomized and observational evidence indicates that percutaneous atherectomy of the femoropopliteal and infrapopliteal arteries may achieve high technical success rates and seems to lessen the frequency of bailout stenting, however, at the expense of increased risk of peri-procedural distal embolization. Long-term clinical outcomes reported to date do not support the superiority of percutaneous atherectomy over traditional balloon angioplasty and stent placement in terms of vessel patency or limb salvage. The combination of debulking atherectomy and drug-coated balloons has shown promise in early studies, especially in the treatment of more complex lesions. Unanswered questions and future perspectives of this continuously evolving endovascular technology as part of a broader treatment algorithm are discussed.

  2. Optical coherence tomography assessment of the mechanistic effects of rotational and orbital atherectomy in severely calcified coronary lesions.

    PubMed

    Kini, Annapoorna S; Vengrenyuk, Yuliya; Pena, Jacobo; Motoyama, Sadako; Feig, Jonathan E; Meelu, Omar A; Rajamanickam, Anitha; Bhat, Arjun M; Panwar, Sadik; Baber, Usman; Sharma, Samin K

    2015-11-15

    This study sought to assess the mechanistic effect of rotational atherectomy (RA) and orbital atherectomy (OA) on heavily calcified coronary lesions and subsequent stent placement using optical coherence tomography (OCT). RA and OA are two main approaches to ablate coronary calcium. While small case reports have described the mechanistic effect of RA in calcified coronary lesions, there has been no imaging study to assess the effect of OA on coronary artery architecture and/or compare the effects of two atherectomy devices. This study analyzed 20 consecutive patients with OCT imaging performed after atherectomy and after stent implantation, RA (n = 10) and OA (n = 10). Postatherectomy OCT analysis identified tissue modification with deep dissections in around a third of lesions after RA and OA; however, post OA dissections ("lacunae") were significantly deeper (1.14 vs. 0.82 mm, P = 0.048). Post OA/RA lesions with dissections had significantly higher percentage of lipid rich plaques and smaller calcification arcs as compared to plaques without dissections. Stents after OA were associated with a significantly lower percent of stent strut malapposition than post RA stents (4.36 vs. 8.02%, P = 0.038). Although the incidence of dissections was comparable between RA and OA cases, OA resulted in deeper tissue modifications (lacunae) as shown by OCT imaging. The finding might provide an explanation for a better stent apposition after OA as compared to RA. Their impact on long-term outcome needs to be determined. © 2015 Wiley Periodicals, Inc.

  3. Successful rotational atherectomy over RG3 guidewire after failure of various techniques to deliver RotaWire.

    PubMed

    Kaneko, Umihiko; Kashima, Yoshifumi; Kanno, Daitaro; Sugie, Takuro; Kobayashi, Ken; Fujita, Tsutomu

    2017-10-01

    Although performing rotational atherectomy (RA) requires guidewire exchange for the dedicated guidewire, RotaWire guidewire (Boston Scientific) exhibits much lower performance than conventional guidewire. Consequently, there are times when RotaWire cannot be advanced past the lesion independently or using a microcatheter exchange technique, rendering RA impossible. We present a case of a heavily calcified, device-uncrossable, and non-expansible chronic total occlusion lesion successfully revascularized with RA over RG3 guidewire (Asahi Intecc), which has a length of 330 cm, hydrophilic coating, and a 0.010-inch-long shaft. RG3 provided excellent cross-ability and RA could also be performed over RG3 without guidewire exchange for the RotaWire.

  4. Comparison of the Efficacy and Safety of Orbital and Rotational Atherectomy in Calcified Narrowings in Patients Who Underwent Percutaneous Coronary Intervention.

    PubMed

    Koifman, Edward; Garcia-Garcia, Hector M; Kuku, Kayode O; Kajita, Alexandre H; Buchanan, Kyle D; Steinvil, Arie; Rogers, Toby; Bernardo, Nelson L; Lager, Robert; Gallino, Robert A; Ben-Dor, Itsik; Pichard, Augusto D; Torguson, Rebecca; Gai, Jiaxiang; Satler, Lowell F; Waksman, Ron

    2018-04-15

    We aimed to compare the safety and efficacy of rotational atherectomy (RA) and orbital atherectomy (OA) during percutaneous coronary intervention in an all-comer population with severely calcified lesions. We included all patients who underwent percutaneous coronary intervention with OA or RA in our institution from October 2013 until October 2016. Comparison of baseline and procedural characteristics, along with acute complication rates and postprocedural cardiac enzyme elevation, was performed. There were 191 RA and 57 OA patients. Other than creatinine clearance, which was lower in patients with OA (p = 0.01), there were no differences in baseline characteristics. OA was more frequent in left anterior descending artery lesions (p = 0.02), whereas RA was more common in right coronary artery lesions (p = 0.01). Intracoronary imaging rates were above 60% in both groups. There was a higher rate of coronary dissections with OA compared with RA (p = 0.003), but there was no difference in periprocedural events. Maximal troponin levels were similar in both groups. Residual stenosis measured by intravascular ultrasound in 29 patients revealed no significant differences between OA and RA (p = 0.58). In conclusion, RA and OA have similar safety and efficacy profiles in treating patients with calcified coronary lesions, and intracoronary imaging is highly beneficial in identifying coronary injury after atherectomy procedures. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Directional coronary atherectomy (DCA)

    MedlinePlus Videos and Cool Tools

    ... catheter called a nosecone, and removed after the intervention is complete. Together with rotation of the catheter, ... artery to keep the vessel open. After the intervention is completed the doctor injects contrast media and ...

  6. Atherectomy for peripheral arterial disease.

    PubMed

    Ambler, Graeme K; Radwan, Rami; Hayes, Paul D; Twine, Christopher P

    2014-03-17

    Symptomatic peripheral arterial disease may be treated by a number of options including exercise therapy, angioplasty, stenting and bypass surgery. Atherectomy is an alternative technique where atheroma is excised by a rotating cutting blade. The objective of this review was to analyse randomised controlled trials comparing atherectomy against any established treatment for peripheral arterial disease in order to evaluate the effectiveness of atherectomy. The Cochrane Peripheral Vascular Diseases Group Trials Search Co-ordinator searched the Specialised Register (last searched November 2013) and CENTRAL (2013, Issue 10). Trials databases were searched for details of ongoing or unpublished studies. Randomised controlled trials (RCTs) comparing atherectomy and other established treatments were selected for inclusion. All participants had symptomatic peripheral arterial disease with either claudication or critical limb ischaemia and evidence of lower limb arterial disease. Two review authors (GA and CT) screened studies for inclusion, extracted data and assessed the quality of the trials. Any disagreements were resolved through discussion. Four trials were included with a total of 220 participants (118 treated with atherectomy, 102 treated with balloon angioplasty) and 259 treated vessels (129 treated with atherectomy, 130 treated with balloon angioplasty). All studies compared atherectomy with angioplasty. No study was properly powered or assessors blinded to the procedures and there was a high risk of selection, attrition, detection and reporting biases.The estimated risk of success was similar between the treatment modalities although the confidence interval (CI) was compatible with small benefits of either treatment for the initial procedural success rate (Mantel-Haenszel risk ratio (RR) 0.92, 95% CI 0.44 to 1.91, P = 0.82), patency at six months (Mantel-Haenszel RR 0.92, 95% CI 0.51 to 1.66, P = 0.79) and patency at 12 months (Mantel-Haenszel RR 1.17, 95% CI 0.72 to 1.90, P = 0.53) following the procedure. The reduction in all-cause mortality with atherectomy was most likely due to an unexpectedly high mortality in the balloon angioplasty group in one of the two trials that reported mortality (Mantel-Haenszel RR 0.24, 95% CI 0.06 to 0.91, P = 0.04). Cardiovascular events were not reported in any study. There was a reduction in the rate of bailout stenting following atherectomy (Mantel-Haenszel RR 0.45, 95% CI 0.24 to 0.84, P = 0.01), and balloon inflation pressures were lower following atherectomy (mean difference -2.73 mmHg, 95% CI -3.48 to -1.98, P < 0.00001). Complications such as embolisation and vessel dissection were reported in two trials indicating more embolisations in the atherectomy group and more vessel dissections in the angioplasty group, but the data could not be pooled. From the limited data available, there was no clear evidence of different rates of adverse events between the atherectomy and balloon angioplasty groups for target vessel revascularisation and above-knee amputation. Quality of life and clinical and symptomatic outcomes such as walking distance or symptom relief were not reported in the studies. This review has identified poor quality evidence to support atherectomy as an alternative to balloon angioplasty in maintaining primary patency at any time interval. There was no evidence for superiority of atherectomy over angioplasty on any outcome, and distal embolisation was not reported in all trials of atherectomy. Properly powered trials are recommended.

  7. Rotational atherectomy ablation for an unexpandable stent under the guide of IVUS

    PubMed Central

    Si, Daoyuan; Liu, Guohui; Tong, Yaliang; He, Yuquan

    2018-01-01

    Abstract Rationale: Inadequate stent expansion due to rigid calcified may result in restenosis lesions, but the available options are limited. Patient concerns: We report a case via the trans-radial approach of the severely underexpanded freshly deployed stent due to heavily calcified plaques Diagnoses: Coronary angiography revealed that there was no adequate expansion of the freshly deployed stent. Interventions: Under the guide of intravascular ultrasound (IVUS), rotational atherectomy (RA) successfully ablated the stent layers and the protruding calcified plaque. Followed by balloon angioplasty, the ablated segment was scaffolded with another stent, well expanded and documented by IVUS. Outcomes: The patient was uneventful during the procedure and remained angina free at the point of one year of clinical follow-up. Lessons: This case indicated that RA via the trans-radial approach could be a useful remedy in the situation of under-expansion of implanted stents, and the debulking should be performed under IVUS-guidance. PMID:29443790

  8. From debulking to delivery: sequential use of rotational atherectomy and Guidezilla™ for complex saphenous vein grafts intervention.

    PubMed

    Pellicano, Mariano; Floré, Vincent; Barbato, Emanuele; De Bruyne, Bernard

    2018-06-19

    Percutaneous coronary interventions (PCI) of old calcified saphenous vein grafts (SVGs) is challenging and is associated with a considerably high risk of adverse ischemic events in the short- and long-term as compared to native coronary arteries. We report a case in which a non-dilatable, calcified SVG lesion is successfully treated with rotational atherectomy followed by PCI and stenting with local stent delivery (LSD) technique using the Guidezilla™ guide extension catheter (5-in-6 Fr) in the "child-in-mother" fashion. A 70 years-old man with a dilated ischemic cardiomyopathy, triple coronary artery bypass grafting (CABG) in 1990 and chronic renal failure (baseline GFR: 45 ml/min/1.73 m 2 ) underwent a coronary angiography for a Non-ST segment elevation myocardial infarction (NSTEMI). Native coronary circulation was completely occluded at the proximal segments. Grafts angiography showed a tandem calcified lesions of SVG on distal right coronary artery (RCA) and an ostial stenosis of the SVG on first obtuse marginal branch (OM1). Left internal mammary artery on the mid left anterior descending artery was patent. Ad Hoc PCI of SVG on RCA was attempted. The proximal calcified stenosis has been crossed with a 1.5 x 12 mm balloon only with the support of Guidezilla™, however the non-compliant (NC) balloon 2.5 x 15 mm was unable to break the hard and calcified plaque. After several attempts, the procedure was interrupted with a suboptimal result. An elective transradial PCI of SVG on RCA with rotational atherectomy was performed. Two runs with 1.25 mm burr and 2 runs with 1.5 mm burr were carried out. Then, the use of distal anchoring balloon warranted support and tracking, made as centring rail for the advance of the tip of the "mother-and-child" catheter into the SVG. During slow deflation of the balloon, the Guidezilla™ was advanced distal to the stenoses to be stented, thus allowing the placement of two long drug eluting stents according to a LSD technique. Rotational atherectomy is a feasible option for non-dilatable stenoses in old SVGs when there is no evidence of thrombus or vessel dissection and the subsequent use of "mother-and-child" catheter has a key role, especially in case of radial approach, for long stents delivery.

  9. JetStream Rotational and Aspiration Atherectomy in Treating In-Stent Restenosis of the Femoropopliteal Arteries: Results of the JETSTREAM-ISR Feasibility Study.

    PubMed

    Shammas, Nicolas W; Shammas, Gail A; Banerjee, Subhash; Popma, Jeffrey J; Mohammad, Atif; Jerin, Michael

    2016-04-01

    To evaluate the outcomes and stent-device interaction of the JetStream atherectomy device in the treatment of in-stent restenosis (ISR) of the femoropopliteal segment. The JetStream XC atherectomy device, a rotational cutter with aspiration capacity, was evaluated in a prospective cohort of 29 patients (mean age 69.9 ± 11.7 years; 11 men) with femoropopliteal ISR in 32 limbs (ClinicalTrials.gov identifier NCT01722877). Lesion length was 17.4 ± 13.1 cm. The primary effectiveness outcome was acute success (≤ 30% residual narrowing with no serious adverse events). The primary safety endpoint was major adverse events. Secondary endpoints included clinically driven target lesion revascularization (TLR) at 6 months and 1 year and loss of stent integrity as assessed by an angiographic core laboratory. Treated length was 19.5 ± 12.9 cm. Acute success was obtained in 29/32 (91%) limbs. Acute device success (<50% residual narrowing after atherectomy alone) was 76% (22/29). Adjunctive balloon angioplasty was performed in all cases at a mean pressure of 11.6 ± 3.3 atm. Embolic filter protection was used in 16 (50%) of 32 limbs. Macrodebris was noted in 2 (12%) of 16 filters. Distal embolization requiring treatment occurred in 3/32 (9.4%) limbs (2 with no filter). Other non-procedure-related adverse events were 1 (3%) death (nonvascular) and 1 (3%) case of major bleeding. There were no new stent fractures or deformities (n=24) postatherectomy. Follow-up was completed on 27 patients (29 limbs) at 6 and 12 months. TLR at these time points occurred in 4/29 (14%) and 12/29 (41%) patients. Patency (duplex-derived peak systolic velocity ratio <2.4) was 72% at 6 months. JetStream atherectomy using the XC device has favorable acute results in treating femoropopliteal ISR with high procedure success, no device-stent interaction, and favorably low TLR rates. A multicenter trial is needed to confirm these results. © The Author(s) 2016.

  10. Coronary Intervention with the Excimer Laser: Review of the Technology and Outcome Data

    PubMed Central

    Rawlins, John; Din, Jehangir N; Talwar, Suneel

    2016-01-01

    Excimer laser coronary atherectomy (ELCA) is a long-established adjunctive therapy that can be applied during percutaneous coronary intervention (PCI). Technical aspects have evolved and there is an established safety and efficacy record across a number of clinical indications in contemporary interventional practice where complex lesions are routinely encountered. The role of ELCA during PCI for thrombus, non-crossable or non-expandable lesions, chronic occlusions and stent under-expansion are discussed in this review. The key advantage of ELCA over alternative atherectomy interventions is delivery on a standard 0.014-inch guidewire. Additionally, the technique can be mastered by any operator after a short period of training. The major limitation is presence of heavy calcification although when rotational atherectomy (RA) is required but cannot be applied due to inability to deliver the dedicated RotaWireTM (Boston Scientific), ELCA can create an upstream channel to permit RotaWire passage and complete the case with RA – the RASER technique. PMID:29588701

  11. Complete "in situ" avulsion of the radial artery complicating transradial coronary rotational atherectomy.

    PubMed

    Mouawad, Nicolas J; Capers, Quinn; Allen, Christopher; James, Iyore; Haurani, Mounir J

    2015-01-01

    Transradial percutaneous access (TR) is promoted because of increased patient comfort and convenience as well as a lower risk of access site and cardiac complications in the literature. Increased use of the TR purports a new set of possible complications for which the vascular surgeon must be capable to recognize and manage. A 48-year-old, devout Jehovah's Witness, woman with a history of coronary artery bypass surgery presented with a non-ST-segment elevation acute myocardial infarction. Pretransfer catheterization demonstrated a heavily calcified, 90% distal left main stenosis with an occluded left internal mammary artery graft to the left anterior descending coronary artery. To minimize the risk of bleeding requiring a blood transfusion, a coronary rotational atherectomy via a TR was performed. A nonhydrophilic, 7F sheath was used to accommodate the larger rotational atherectomy burr sizes. The coronary procedure was successful, but the sheath removal was complicated by significant resistance to pullback while the patient complained of severe pain. Post procedure she developed a hematoma with motor and neurological deficits of her hand. Emergent surgical exploration with fasciotomy was planned. The radial artery was explored and found to be redundant and pulseless, prompting proximal evaluation and revealing complete avulsion of the radial artery at its origin. An intraoperative arteriogram revealed that the brachial and ulnar arteries and interosseous branches were patent and filled the palmar arch and surgical ligation of the radial artery was conducted. Vascular surgeons need to be aware of potential complications related to TR which are likely to increase as this method is more widely disseminated. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Tissue removal by ultrasound evaluation (the TRUE study): the Jetstream G2 system post-market peripheral vascular IVUS study.

    PubMed

    Singh, Tejwant; Koul, Deepak; Szpunar, Susanna; Torey, James; Dhabuwala, Jigishu; Saigh, Lisa; Pires, Luis A; Davis, Thomas

    2011-07-01

    Balloon angioplasty and stenting of infra-inguinal lesions is limited by poor long-term patency rates. Atherectomy decreases plaque burden and provides an alternative means of revascularizing patients with peripheral arterial disease. The Jetstream G2™ (Pathway Medical Technologies, Inc., Kirkland, Washington) is a newer rotational aspiration atherectomy device, uniquely combining rotablation with aspiration capability. We evaluated the debulking properties of this device by analyzing changes in the plaque volume and composition and vessel size using intravascular ultrasound (IVUS) and virtual histology (VH). Freedom from target lesion revascularization (TLR) at 6 and 12 months was also evaluated. Eighteen patients with peripheral arterial disease requiring intervention (severe claudication despite optimal medical treatment or critical limb ischemia) were treated with rotational atherectomy. The mean age was 69.6 ± 11 years, 66.7% were male, and 44.4% had diabetes. The mean total plaque volume decreased by 56.6 mm³ (479.8 ± 172.5 mm³ to 423.2 ± 156.6 mm³; p < 0.0001), which resulted in a mean luminal volume increase of 64.3 mm³ (148.4 ± 84.1 mm³ to 212.7 ± 72.1 mm³; p < 0.0001). This was achieved without significant Dotter effect with either technique, as evidenced by the virtually unchanged vessel volume before and after treatment (628.3 ± 158.5 mm³ and 635.9 ± 169.0 mm³, respectively; p = 0.22). There was a significant reduction in fibrotic and fibro-fatty plaque volume, with no appreciable effect on necrotic core and dense calcium. There were no reported procedure-related complications and the 6- and 12-month TLR rate was 11% (2/18). Atherectomy with the Jetstream G2 system results in substantial plaque volume reduction by removing fibrotic and fibro-fatty plaque. This resulted in substantial luminal volume expansion without concomitant vessel expansion. There were no major procedure-related complications, along with a relatively low 6- and 12-month rate of TLR. Future studies involving a larger number of patients are warranted to examine the potential clinical benefits of this promising technology.

  13. A rotational ablation tool for calcified atherosclerotic plaque removal.

    PubMed

    Kim, Min-Hyeng; Kim, Hyung-Jung; Kim, Nicholas N; Yoon, Hae-Sung; Ahn, Sung-Hoon

    2011-12-01

    Atherosclerosis is a major cardiovascular disease involving accumulations of lipids, white blood cells, and other materials on the inside of artery walls. Since the calcification found in the advanced stage of atherosclerosis dramatically enhances the mechanical properties of the plaque, restoring the original lumen of the artery remains a challenge. High-speed rotational atherectomy, when performed with an ablating grinder to remove the plaque, produces much better results in the treatment of calcified plaque compared to other methods. However, the high-speed rotation of the Rotablator commercial rotational atherectomy device produces microcavitation, which should be avoided because of the serious complications it can cause. This research involves the development of a high-speed rotational ablation tool that does not generate microcavitation. It relies on surface modification to achieve the required surface roughness. The surface roughness of the tool for differential cutting was designed based on lubrication theory, and the surface of the tool was modified using Nd:YAG laser beam engraving. Electron microscope images and profiles indicated that the engraved surface of the tool had approximately 1 μm of root mean square surface roughness. The ablation experiment was performed on hydroxyapatite/polylactide composite with an elastic modulus similar to that of calcified plaque. In addition, differential cutting was verified on silicone rubber with an elastic modulus similar to that of a normal artery. The tool performance and reliability were evaluated by measuring the ablation force exerted, the size of the debris generated during ablation, and through visual inspection of the silicone rubber surface.

  14. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis.

    PubMed

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A; Quiles, Katherine G; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2018-01-01

    The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis.

  15. Intravascular ultrasound guided directional atherectomy versus directional atherectomy guided by angiography for the treatment of femoropopliteal in-stent restenosis

    PubMed Central

    Krishnan, Prakash; Tarricone, Arthur; K-Raman, Purushothaman; Majeed, Farhan; Kapur, Vishal; Gujja, Karthik; Wiley, Jose; Vasquez, Miguel; Lascano, Rheoneil A.; Quiles, Katherine G.; Distin, Tashanne; Fontenelle, Ran; Atallah-Lajam, Farah; Kini, Annapoorna; Sharma, Samin

    2017-01-01

    Background: The aim of this study was to compare 1-year outcomes for patients with femoropopliteal in-stent restenosis using directional atherectomy guided by intravascular ultrasound (IVUS) versus directional atherectomy guided by angiography. Methods and results: This was a retrospective analysis for patients with femoropopliteal in-stent restenosis treated with IVUS-guided directional atherectomy versus directional atherectomy guided by angiography from a single center between March 2012 and February 2016. Clinically driven target lesion revascularization was the primary endpoint and was evaluated through medical chart review as well as phone call follow up. Conclusions: Directional atherectomy guided by IVUS reduces clinically driven target lesion revascularization for patients with femoropopliteal in-stent restenosis. PMID:29265002

  16. High-speed coronary rotational angioplasty with the rotablator

    NASA Astrophysics Data System (ADS)

    Zacca, Nadim M.; Kleiman, Neal S.; Asimacopoulos, P. J.

    1992-08-01

    Percutaneous mechanical rotational ablation with the rotablator can be used effectively as a stand alone treatment for coronary arterial lesions, including those with angiographic morphology considered unfavorable for balloon angioplasty (eccentric, at bends, bifurcating, calcified, ulcerated, completely occluded_, as well as for balloon angioplasty procedure failures. The use of single rather than multiple burrs without balloon assistance, the use of fewer passes and of the nitroglycerine infusion through the rotablator catheter have considerably shortened the time necessary to complete a rotational atherectomy. Further, the apparently infrequent occurrence of post procedure abrupt closure makes this technique attractive in the clinical management of patients with complex coronary artery lesions.

  17. Rotational atherectomy as endovascular haute couture: a road map of tools and techniques for the interventional management of burr entrapment.

    PubMed

    Dahdouh, Ziad; Abdel-Massih, Tony; Roule, Vincent; Sarkis, Antoine; Grollier, Gilles

    2013-12-01

    Rotational atherectomy (RA) is used as a debulking technique prior to stenting in some specialized cardiac centers for calcified coronary lesions amenable to percutaneous coronary intervention (PCI). A specific possible complication, burr entrapment, is unusual but carries serious risks and may sometimes necessitate surgery as a rescue procedure. However, different modalities using a percutaneous approach were proposed as a bail-out. We aim to propose a framework for possible management for trapped RA burr. A literature review of the most relevant cases of entrapped burr during PCI was performed. Twelve cases were reported and different solutions were discussed. Surgery was needed in only 1 patient to retrieve the trapped burr, and in all the other cases, different percutaneous solutions were successful to retract the trapped device. These cases illustrate that burr entrapment during RA, albeit rare, may occur and may transform a relatively simple PCI to a procedure failure. Although prevention is better than treatment, the operators should be aware of such serious complication and they should keep in mind that various possible percutaneous solutions may be successful to retrieve the burr and to avoid surgery. © 2013, Wiley Periodicals, Inc.

  18. Atherectomy devices: technology update

    PubMed Central

    Akkus, Nuri I; Abdulbaki, Abdulrahman; Jimenez, Enrique; Tandon, Neeraj

    2015-01-01

    Atherectomy is a procedure which is performed to remove atherosclerotic plaque from diseased arteries. Atherosclerotic plaques are localized in either coronary or peripheral arterial vasculature and may have different characteristics depending on the texture of the plaque. Atherectomy has been used effectively in treatment of both coronary and peripheral arterial disease. Atherectomy devices are designed differently to either cut, shave, sand, or vaporize these plaques and have different indications. In this article, current atherectomy devices are reviewed. PMID:25565904

  19. Number of Blades-up Runs Using JetStream XC Atherectomy for Optimal Tissue Debulking in Patients with Femoropopliteal Artery In-Stent Restenosis.

    PubMed

    Shammas, Nicolas W; Shammas, Gail A; Aasen, Nicole; Jarvis, Gary

    2015-12-01

    Rotational atherectomy with the use of the JetStream XC device is indicated for treatment of infrainguinal arterial obstructive disease. The number of blades-up (BU) runs needed for optimal tissue debulking in femoropopliteal in-stent restenosis (ISR) is unknown. In the present series, 6 patients (15 lesions) were treated for femoropopliteal ISR with the JetStream XC device. Minimal luminal diameter or percent stenosis improved significantly from baseline after 2 BU runs, but no further gain was seen between 2 and 4 BU runs (P > .05). However, adjunctive balloon angioplasty reduced percent stenosis significantly following BU runs. In conclusion, the JetStream XC device achieved optimal acute angiographic results in treating femoropopliteal ISR following 2 BU runs and adjunctive balloon angioplasty. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  20. Percutaneous treatment of delayed post-atherectomy superficial femoral artery pseudoaneurysm.

    PubMed

    Akkus, Nuri Ilker; Fay, Matt; Varma, Jai

    2012-10-01

    SilverHawk atherectomy is commonly used in lower extremity percutaneous interventions. Minor perforations during SilverHawk atherectomy procedures are reported at a range of 0.8%. There are few reported cases in the literature about very late pseuodoaneursym formation after SilverHawk atherectomy. Herein we report a very unusual, late, concealed, acute rupture of superficial femoral artery with a large, painful pseuodoaneursym formation, 1 week after Silver- Hawk atherectomy and its treatment with Viabahn stent graft (W.L. Gore & Associates).

  1. Is Atherectomy the Best First-Line Therapy for Limb Salvage in Patients With Critical Limb Ischemia?

    PubMed Central

    Loor, Gabriel; Skelly, Christopher L.; Wahlgren, Carl-Magnus; Bassiouny, Hisham S.; Piano, Giancarlo; Shaalan, Wael

    2010-01-01

    Objective To determine the efficacy of atherectomy for limb salvage compared with open bypass in patients with critical limb ischemia. Methods Ninety-nine consecutive bypass and atherectomy procedures performed for critical limb ischemia between January 2003 and October 2006 were reviewed. Results A total of 99 cases involving TASC C (n = 43, 44%) and D (n = 56, 56%) lesions were treated with surgical bypass in 59 patients and atherectomy in 33 patients. Bypass and atherectomy achieved similar 1-year primary patency (64% vs 63%; P = .2). However, the 1-year limb salvage rate was greater in the bypass group (87% vs 69%; P = .004). In the tissue loss subgroup, there was a greater limb salvage rate for bypass patients versus atherectomy (79% vs 60%; P = .04). Conclusions Patients with critical limb ischemia may do better with open bypass compared with atherectomy as first-line therapy for limb salvage. PMID:19640919

  2. Orbital atherectomy: device evolution and clinical data.

    PubMed

    Staniloae, Cezar S; Korabathina, Ravikiran

    2014-05-01

    A number of atherectomy devices were developed in the last few years. Among them, the DiamondBack 360° Peripheral Orbital Atherectomy System (Cardiovascular Systems, Inc) was specifically designed to work in severely calcified plaque. This article reviews the history, mechanism of action, evolution, clinical data, and future applications of this particular atherectomy device.

  3. Endovascular Management of the Popliteal Artery: Comparison of Atherectomy and Angioplasty

    PubMed Central

    Semaan, Elie; Hamburg, Naomi; Nasr, Wael; Shaw, Palma; Eberhardt, Robert; Woodson, Jonathan; Doros, Gheorghe; Rybin, Denis; Farber, Alik

    2013-01-01

    Purpose Symptomatic atherosclerotic disease of the popliteal artery presents challenges for endovascular therapy. We evaluated the technical success, complications and midterm outcomes of atherectomy and angioplasty involving the popliteal segment. Methods We conducted a retrospective review of outcomes of popliteal artery intervention using atherectomy or angioplasty performed between 2003 and 2008. Results A total of 56 patients (36% women, age 72.8±12.2 years, 77% critical limb ischemia) underwent popliteal atherectomy (n=18) or angioplasty (n=38). These patients had similar clinical characteristics, TASC/TASC II classification, mean lesion length, and run-off scores. We observed a trend toward higher rates of technical success defined as <30% residual stenosis after atherectomy compared to angioplasty (94% vs. 71%, p=0.08). While angioplasty was associated with a higher frequency of arterial dissection (23% vs. 0%, p=0.003), atherectomy was associated with a higher rate of thromboembolic events (22% vs 0%, p=0.01). Adjunctive stenting was used more frequently following angioplasty compared to atherectomy (45% vs. 6%, p=0.005). Thrombolysis was used to treat embolization in 4 patients in the atherectomy group. The improvement in the ankle-brachial index was similar between the two treatment groups. Primary patency of the popliteal artery at 3, 6, and 12 months was 94%, 88%, and 75% in the atherectomy group and 89%, 82%, and 73% in the angioplasty group (p=NS). There were no significant differences in limb salvage and freedom from reintervention at 1 year between the atherectomy and angioplasty groups. Conclusions Our experience with popliteal artery endovascular therapy indicates a distinct pattern of procedural complications with atherectomy compared to angioplasty but similar midterm patency, limb salvage and freedom from intervention. PMID:19942598

  4. Percutaneous lower-extremity arterial interventions with primary balloon angioplasty versus Silverhawk atherectomy and adjunctive balloon angioplasty: randomized trial.

    PubMed

    Shammas, Nicolas W; Coiner, Denise; Shammas, Gail A; Dippel, Eric J; Christensen, Lori; Jerin, Michael

    2011-09-01

    Target lesion revascularization (TLR) with primary percutaneous transluminal angioplasty (PTA) versus SilverHawk atherectomy and adjunctive PTA of de novo infrainguinal disease has not been well defined. This study was conducted to compare the two approaches. In this prospective, two-center randomized trial of PTA versus atherectomy of infrainguinal vessels, the primary endpoint of TLR was evaluated at 1 year. Secondary endpoints included the rate of "bailout" stent placement for suboptimal acute angiographic results and the rate of target vessel revascularization (TVR). Fifty-eight patients were included in the study. Of these, 29 (36 vessels) were randomized to the atherectomy arm and 29 (48 vessels) to the PTA arm. Final acute angiographic success rates were 100% in the PTA arm and 97.2% in the atherectomy arm (P value not significant). There was no statistical difference in TLR (16.7% vs 11.1%) or TVR (21.4% vs 11.1%) between the PTA and atherectomy groups, respectively. Bailout stent placement was performed in 18 of 29 patients (62.1%) in the PTA arm and eight of 29 patients (27.6%) in the atherectomy arm (P = .017). Major adverse events were similar between the PTA and atherectomy arms. Finally, when embolic filter protection was used, distal macroembolization occurred in 11 of 17 patients (64.7%) treated with atherectomy versus none of 10 in the PTA group (P < .001). TLR and TVR at 1 year were statistically similar in atherectomy and primary PTA. Atherectomy reduced the need for bailout stent placement compared with primary PTA. Copyright © 2011 SIR. Published by Elsevier Inc. All rights reserved.

  5. Evolution of atherectomy devices.

    PubMed

    Al Khoury, G; Chaer, R

    2011-08-01

    Percutaneous atherectomy provides an alternative approach to the endovascular treatment of peripheral atherosclerotic occlusive disease beyond angioplasty and stenting, and has the theoretical advantage of lesion debulking and minimizing barotrauma to the vessel wall. Atherectomy has evolved greatly during the last decade, with currently four FDA approved devices for the treatment of peripheral arterial disease. Several reports have focused on the initial technical success rates, and demonstrated the safety and short as well as mid-term efficacy of atherectomy devices. This article will review the evolution of current atherectomy devices and the associated literature.

  6. In-Hospital Outcomes of Atherectomy During Endovascular Lower Extremity Revascularization.

    PubMed

    Panaich, Sidakpal S; Arora, Shilpkumar; Patel, Nilay; Patel, Nileshkumar J; Patel, Samir V; Savani, Chirag; Singh, Vikas; Jhamnani, Sunny; Sonani, Rajesh; Lahewala, Sopan; Thakkar, Badal; Patel, Achint; Dave, Abhishek; Shah, Harshil; Bhatt, Parth; Jaiswal, Radhika; Ghatak, Abhijit; Gupta, Vishal; Deshmukh, Abhishek; Kondur, Ashok; Schreiber, Theodore; Grines, Cindy; Badheka, Apurva O

    2016-02-15

    Contemporary data on clinical outcomes after utilization of atherectomy in lower extremity endovascular revascularization are sparse. The study cohort was derived from Healthcare Cost and Utilization Project nationwide inpatient sample database from the year 2012. Peripheral endovascular interventions including atherectomy were identified using appropriate International Classification of Diseases, Ninth Revision, Clinical Modification diagnostic and procedural codes. The subjects were divided and compared in 2 groups: atherectomy versus no atherectomy. Two-level hierarchical multivariate mixed models were created. The coprimary outcomes were in-hospital mortality and amputation; secondary outcome was a composite of in-hospital mortality and periprocedural complications. Hospitalization costs were also assessed. Atherectomy utilization (odds ratio, 95% CI, p value) was independently predictive of lower in-hospital mortality (0.46, 0.28 to 0.75, 0.002) and lower amputation rates (0.83, 0.71 to 0.97, 0.020). Atherectomy use was also predictive of significantly lower secondary composite outcome of in-hospital mortality and complications (0.79, 0.69 to 0.90, 0.001). In the propensity-matched cohort, atherectomy utilization was again associated with a lower rate of amputation (11.18% vs 12.92%, p = 0.029), in-hospital mortality (0.71% vs 1.53%, p 0.001), and any complication (13.24% vs 16.09%, p 0.001). However, atherectomy use was also associated with higher costs ($24,790 ± 397 vs $22635 ± 251, p <0.001). Atherectomy use in conjunction with angioplasty (with or without stenting) was associated with improved in-hospital outcomes in terms of lower amputation rates, mortality, and postprocedural complications. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. [Meta-analysis of percutaneous transluminal atherectomy in the treatment for in-stent restenosis of lower extremity peripheral artery disease].

    PubMed

    Li, Weihao; Zhang, Tao; Liu, Yunfeng; Zhang, Yongbao; Li, Qingle; Zhang, Xiaoming; Shen, Chenyang

    2015-11-24

    To evaluate the clinical safety and efficacy of percutaneous transluminal atherectomy for in-stent restenosis (ISR) in patients with low extremity peripheral arterial diseases (PAD). PubMed, Elsevier, EBSCO, Spring databases and Cochrane Library were searched for relevant articles. Based on the different mechanisms of atherectomy, the patients were divided into mechanic atherectomy group and laser atherectomy group. The safety end points included the rate of distal embolism and severe arterial wall injuries. And the efficacy end points included primary patency rate and freedom from target vessel revascularization (TVR-free) 6 months and 12 months after surgery. A total of 9 studies and 620 patients (published between 2006 and 2014) were accepted. The rate of distal embolism was 4.2% (95% confidence interval (CI): 1.7%-6.7%), while that of severe arterial wall injuries was 1.9% (95%CI: 0.9%-3.0%), respectively. Laser atherectomy was responsible for more distal embolism (6.8%) compared to mechanic atherectomy (2.0%), which was significantly different (Q=21.66, P=0.010). At 6-month follow-up, primary patency rate and rate of TVR-free were 63.0% (95% CI: 55.5%-70.6%) and 80.4% (95% CI: 70.5%-90.3%), while at 12-month follow-up were 43.5% (95%CI: 32.2%-54.9%) and 58.0% (95% CI: 52.1%-63.9%), respectively. The free-TVR rate at 6 months follow-up in mechanical atherectomy group was 77.9%, and was inferior to that in laser atherectomy group (80.8%, Q=13.49, P=0.009). Published bias was discovered at the analysis of 12-month TVR-free rate by means of Begg Test (P=0.039). Meta analysis concerned about the 3 randomized controlled trials demonstrated that there was no significant improvement using atherectomy for ISR comparing to standard balloon at 6-month TVR-free rate (OR=1.34, 95% CI: 0.86-2.07, P=0.196). To treat ISR lesion in lower extremities, laser atherectomy has a lower free-TVR rate in the middle term follow-up.A higher rate of distal embolism is noted though. On balance, percutaneous transluminal atherectomy demonstrates no significant improvement compared to plain balloon angioplasty for ISR lesions.

  8. Aggressive plaque modification with rotational atherectomy and cutting balloon for optimal stent expansion in calcified lesions

    PubMed Central

    Tang, Zhe; Bai, Jing; Su, Shao-Ping; Lee, Pui-Wai; Peng, Liang; Zhang, Tao; Sun, Ting; Nong, Jing-Guo; Li, Tian-De; Wang, Yu

    2016-01-01

    Objective To evaluate the factors affecting optimal stent expansion in calcified lesions treated by aggressive plaque modification with rotational atherectomy (RA) and a cutting balloon (CB). Methods From January 2014 to May 2015, 92 patients with moderate to severe coronary calcified lesions underwent rotational atherectomy and intravascular ultrasound imaging at Chinese PLA General Hospital (Beijing, China) were included in this study. They were divided into a rotational artherectomy combined with cutting balloon (RACB) group (46 patients treated with RA followed by CB angioplasty) and an RA group (46 patients treated with RA followed by plain balloon angioplasty). Another 40 patients with similar severity of their calcified lesions treated with plain old balloon angioplasty (POBA) were demographically matched to the other groups and defined as the POBA group. All patients received a drug-eluting stent after plaque preparation. Lumen diameter and lumen diameter stenosis (LDS) were measured by quantitative coronary angiography at baseline, after RA, after dilatation, and after stenting. Optimal stent expansion was defined as the final LDS < 10%. Results The initial and post-RA LDS values were similar among the three groups. However, after dilatation, the LDS significantly decreased in the RACB group (from 54.5% ± 8.9% to 36.1% ± 7.1%) but only moderately decreased (from 55.7% ± 7.8% to 46.9% ± 9.4%) in the RA group (time × group, P < 0.001). After stenting, there was a higher rate of optimal stent expansion in the RACB group (71.7% in the RACB group, 54.5% in the RA group, and 15% in the POBA group, P < 0.001), and the final LDS was significantly diminished in the RACB group compared to the other two groups (6.0% ± 2.3%, 10.8% ± 3.3%, 12.7% ± 2.1%, P < 0.001). Moreover, an LDS ≤ 40% after plaque preparation (OR = 2.994, 95% CI: 1.297–6.911) was associated with optimal stent expansion, which also had a positive correlation with the appearance of a calcified ring split (r = 0.581, P < 0.001). Conclusions Aggressive plaque modification with RA and CB achieve more optimal stent expansion. An LDS ≤ 40% after plaque modification was a predictive factor for optimal stent expansion in calcified lesions. This parameter was also associated with the presence of calcified ring split. PMID:28321242

  9. OCT evaluation of directional atherectomy compared to balloon angioplasty.

    PubMed

    Marmagkiolis, Konstantinos; Lendel, Vasili; Cilingiroglu, Mehmet

    2015-09-01

    Directional atherectomy (DA) is one of the most commonly used modalities for the treatment of obstructive femoropopliteal peripheral arterial disease (PAD), especially in patients with large and calcified atherosclerotic plaques. The effect of directional atherectomy to the vascular wall compared to balloon angioplasty by optical coherence tomography (OCT) has not been previously described. We present the first case of OCT after directional atherectomy with SilverHawk followed by angiosculpt balloon angioplasty. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Laser Atherectomy for Treatment of Femoropopliteal In-Stent Restenosis.

    PubMed

    Armstrong, Ehrin J; Thiruvoipati, Thejasvi; Tanganyika, Kundai; Singh, Gagan D; Laird, John R

    2015-08-01

    To investigate if laser atherectomy with adjunctive balloon angioplasty can improve endovascular treatment outcomes for femoropopliteal in-stent restenosis (ISR). A dual center study included 135 symptomatic patients (mean age 71 years; 76 men) who underwent endovascular treatment of femoropopliteal ISR between 2006 and 2013. Of these, 54 (40%) were treated with laser atherectomy and the remaining 81 patients with balloon angioplasty alone. Angiographic images were reviewed for lesion morphology and characteristics, TransAtlantic InterSociety Consensus (TASC) II classification, and distal runoff. Class I ISR was defined as focal lesions ≤50 mm, class II ISR as lesions >50 mm, and class III ISR as stent total occlusion. Recurrent ISR was determined by a peak systolic velocity ratio >2.4 by duplex ultrasound. Patients treated with laser atherectomy had longer mean ISR lesion length (222 vs 114 mm, p<0.001) and more class III ISR (69% vs 20%, p=0.001). There was no association between laser atherectomy and rates of recurrent restenosis or occlusion for patients with class I/II ISR, but there was a significantly lower rate of target lesion revascularization at 2 years among patients treated with laser atherectomy (14% vs 44%, p=0.05). In comparison, patients with class III ISR treated with laser atherectomy had lower rates of recurrent restenosis at 1 year (54% vs 91%, p=0.05) and 2 years (69% vs 100%, p=0.05). Patients with class III ISR treated with laser atherectomy also had lower rates of recurrent in-stent occlusion at 2-year follow-up (33% vs 71%, p=0.04). When used to treat complex ISR, including in-stent occlusions, laser atherectomy with adjunctive balloon angioplasty may be associated with improved patency. © The Author(s) 2015.

  11. Orbital Atherectomy in the Renal Artery: A New Frontier for an Emerging Technology?

    PubMed

    Valle, Javier A; Armstrong, Ehrin J; Waldo, Stephen W

    2017-01-01

    Orbital atherectomy has been developed as a method to modify calcified plaque in the peripheral vasculature, with extensive experience and data supporting its use in infrainguinal peripheral arterial disease. However, calcific atherosclerotic disease occurs in other vascular beds and may benefit from the application of this technology. In this case report, we describe the first reported use of orbital atherectomy in a renal artery. A 55-year-old male with severe drug-refractory hypertension was found to have renal artery stenosis, with severe calcification of the right renal artery. Orbital atherectomy was utilized for initial plaque modification, and he underwent stenting of the renal artery lesion with an excellent angiographic and clinical result at follow-up. In conclusion, orbital atherectomy is a safe and effective means of plaque modification for severely calcified lesions. The safe and effective use of orbital atherectomy in the renal vasculature suggests an opportunity for ongoing evaluation into expanded roles for this technology beyond the coronary and lower-extremity arterial beds.

  12. Atherectomy offers no benefits over balloon angioplasty in tibial interventions for critical limb ischemia.

    PubMed

    Todd, Kevin E; Ahanchi, Sadaf S; Maurer, Christian A; Kim, Jung H; Chipman, Candice R; Panneton, Jean M

    2013-10-01

    Endovascular adjuncts, like atherectomy, were developed to improve outcomes of endovascular arterial interventions. The true impact of atherectomy on endovascular outcomes remains to be determined, and little data exist on the influence of atherectomy on tibial interventions. Our study compares early and late outcomes of tibial intervention with angioplasty vs atherectomy-assisted interventions. We completed a retrospective review of all tibial interventions between 2008 and 2010. Outcomes were analyzed using single and multivariate analysis, Cox regression, and Kaplan-Meier curves. Primary outcomes were primary, primary assisted, and secondary patency rates, as well as limb salvage and survival rates. Over a 2-year period, 480 tibial interventions were completed for 421 patients. Eighty-seven percent (n = 418) of interventions were performed for critical limb ischemia (CLI) and 13% (n = 62) for claudication. The CLI cohort of 418 interventions was analyzed. These patients had a mean age of 71 years with a mean follow-up time of 16 ± 15 months (range, 0-59 months). Of the 418 interventions, 339 underwent percutaneous transluminal angioplasty (PTA): 333 PTA alone, six PTA + stent. The remaining 79 interventions received atherectomy: 33 laser, 13 directional, and 33 orbital either alone or in conjunction with PTA (11 atherectomy only, 68 atherectomy + PTA). The groups did not differ significantly in terms of demographics, risk factors, or technical success. The atherectomy group had more TASC B lesions (54% vs 38%; P = .013), while the PTA-alone group had more TASC D lesions (25% vs 13%; P = .004). TASC A and C lesions did not differ significantly between the groups. No significant differences existed with respect to the early (30-day) outcomes of loss of patency (11% vs 13%; P = .699), complications (8% vs 13%; P = .292), or major amputation (17% vs 13%; P = .344) in the PTA-alone group vs the atherectomy-assisted group. Kaplan-Meier analysis revealed no difference for all primary outcomes of PTA alone vs the atherectomy-assisted group at 12 and 36 months: primary patency (69%, 55% vs 61%, 46%; P = .158), primary assisted patency (83%, 71% vs 85%, 67%; P = .801), secondary patency (94%, 89% vs 95%, 89%; P = .892), limb salvage (79%, 70% vs 81%, 77%; P = .485), or survival (77%, 56% vs 80%, 50%; P = .944). The adjunctive use of atherectomy offered no improvement in primary outcomes over PTA alone in either early or late outcomes in CLI patients who underwent endovascular tibial interventions. Considering the additional cost and increased procedural time, these findings put into question the routine use of adjunctive atherectomy. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  13. Very high-pressure dilatation for undilatable coronary lesions: indications and results with a new dedicated balloon.

    PubMed

    Secco, Gioel Gabrio; Ghione, Matteo; Mattesini, Alessio; Dall'Ara, Gianni; Ghilencea, Liviu; Kilickesmez, Kadriye; De Luca, Giuseppe; Fattori, Rossella; Parisi, Rosario; Marino, Paolo Nicola; Lupi, Alessandro; Foin, Nicolas; Di Mario, Carlo

    2016-06-20

    Calcific coronary lesions impose a rigid obstacle to optimal balloon and stent expansion and the 20 to 30 atm limit that non-compliant (NC) balloons reach can be insufficient. The aim of our study was to evaluate the safety and efficacy of a new dedicated super high-pressure NC balloon (OPN NC®; SIS Medical AG, Winterthur, Switzerland). We retrospectively evaluated a consecutive series of 91 lesions in which conventional NC balloons at maximal pressure failed to achieve an adequate post-dilatation luminal gain and were therefore treated with an OPN NC balloon up to 40 atm. Angiographic success was defined as residual angiographic diameter stenosis <30%. MLD and %DS were measured at baseline, after NC balloon, OPN NC balloon and stent implantation. Angiographic success was achieved in 84 lesions (92.3%). All of the remaining lesions received rotational atherectomy with the exception of two cases in which rotational atherectomy was not attempted because of small vessel size and excessive tortuosity. MLD and acute gain were significantly greater and %DS was significantly lower post OPN NC balloon compared with conventional NC balloon inflation (p<0.001). No coronary perforations occurred. No acute or 30-day follow-up MACE was reported. When conventional NC balloons fail, the new OPN NC dedicated high-pressure balloon provides an effective and safe alternative strategy for the dilatation of resistant coronary lesions.

  14. Peripheral Atherectomy: Applications and Techniques.

    PubMed

    Mittleider, Derek; Russell, Erich

    2016-06-01

    Peripheral atherectomy is a class of procedures that is rapidly increasing in volume. Multiple classes of devices exist, and newer variants are added to the market annually. The devices see wide application for de novo lesions, in-stent restenosis, and adjunctive therapy for drug-coated balloons. The body of evidence supporting atherectomy is less robust than for many other peripheral therapies. The frequency and severity of complications from atherectomy can be significant compared with angioplasty and stenting, and familiarity with preventative and bailout techniques is essential for the interventionalist. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Short-term outcomes of excisional atherectomy in lower limb arterial disease.

    PubMed

    Werner-Gibbings, Keagan; Dubenec, Steven

    2017-06-01

    Endovascular interventions are increasingly utilized in managing occlusive peripheral vascular disease. Angioplasty and stenting remain the mainstay of endovascular management; however, newer treatment modalities such as excisional atherectomy provide the clinician with additional treatment options. While demonstrating promising results in available trials, a paucity of data exist regarding peripheral atherectomy. The purpose of this retrospective clinical study was to assess the efficacy and safety of excisional atherectomy with the TurboHawk atherectomy device (Covidien/ev3, Plymouth, MN, USA) in the treatment of lower limb peripheral vascular disease and to evaluate the learning curve involved in the institution of a new treatment modality. A retrospective analysis was performed on all patients undergoing atherectomy for symptomatic lower limb peripheral vascular disease by a single clinician between November 2011 and June 2013. Forty-seven vessels on 28 legs in 24 patients were treated during the period. Atherectomy was possible in 98% of cases. The 6- and 12-month primary patency was 72.6 and 58.9%, respectively. The primary-assisted patency was 93.2% at 6 months and 74.6% at 12 months. There were significantly greater patency rates in the TransAtlantic Inter-Society Consensus A + B lesions and a non-significant trend towards improved patency rates in claudicants versus critical limb ischaemia. There were four instances of embolization and four cases of dissection. Excisional atherectomy provides a further option for the minimally invasive management of peripheral vascular disease. It has similar patency rates to established endovascular therapies and should be considered among the treatment options in patients with favourable pathology. © 2014 Royal Australasian College of Surgeons.

  16. Outcomes in Diabetic Patients Undergoing Orbital Atherectomy System.

    PubMed

    Lee, Michael S; Shlofmitz, Evan; Nguyen, Heajung; Shlofmitz, Richard A

    2016-10-01

    We evaluated the angiographic and clinical outcomes of orbital atherectomy to treat severely calcified coronary lesions in diabetic and non-diabetic patients. Diabetics have increased risk for death, myocardial infarction, and target vessel revascularization after percutaneous coronary intervention. Severely calcified coronary lesions are associated with increased cardiac events. Orbital atherectomy facilitates stent delivery and optimizes stent expansion by modifying severely calcified plaque. Outcomes in diabetic patients who undergo orbital atherectomy have not been reported. Our retrospective multicenter registry included 458 consecutive real-world patients with severely calcified coronary arteries who underwent orbital atherectomy. The primary safety endpoint was the rate of major adverse cardiac and cerebrovascular events at 30 days. Diabetics represented 42.1% (193/458) of the entire cohort. The primary endpoint was similar in diabetics and non-diabetics (1.0% vs. 3.0%%, P = 0.20), as were 30-day rates of death (0.5% vs. 1.9%, P = 0.41), myocardial infarction (0.5% vs. 1.5%, P = 0.40), target vessel revascularization (0% vs. 0%, P = 1), and stroke (0% vs. 0.4%, P > 0.9). Angiographic complications and stent thrombosis rate were low and did not differ between the 2 groups. Diabetics represented a sizeable portion of patients who underwent orbital atherectomy. Diabetics who had severely calcified coronary arteries and underwent orbital atherectomy had low event rates that were similar to non-diabetics. Orbital atherectomy appears to be a viable treatment strategy for diabetic patients. Randomized trials with longer-term follow-up are needed to determine the ideal treatment strategy for diabetics. © 2016, Wiley Periodicals, Inc.

  17. Incidence of Bradycardia and Outcomes of Patients Who Underwent Orbital Atherectomy Without a Temporary Pacemaker.

    PubMed

    Lee, Michael S; Nguyen, Heajung; Shlofmitz, Richard

    2017-02-01

    We analyzed the incidence of bradycardia and the safety of patients with severely calcified coronary lesions who underwent orbital atherectomy without the insertion of a temporary pacemaker. The presence of severely calcified coronary lesions can increase the complexity of percutaneous coronary intervention due to the difficulty in advancing and optimally expanding the stent. High-pressure inflations to predilate calcified lesions may cause angiographic complications like perforation and dissection. Suboptimal stent expansion is associated with stent thrombosis and restenosis. Orbital atherectomy safely and effectively modifies calcified plaque to facilitate optimal stent expansion. The incidence of bradycardia in orbital atherectomy is unknown. Fifty consecutive patients underwent orbital atherectomy from February 2014 to September 2016 at our institution, none of whom underwent insertion of a temporary pacemaker. The final analysis included 47 patients in this retrospective study as 3 patients were excluded because of permanent pacemaker implantation. The primary endpoint was significant bradycardia, defined as bradycardia requiring emergent pacemaker placement or a heart rate <50 bpm at the end of atherectomy. The primary endpoint occurred in 4% of all patients, all driven by patients who experienced a heart rate decreasing to <50 bpm. The major adverse cardiac and cerebral event rate was 6%, driven by death (2%) and myocardial infarction (4%). No patient experienced target-vessel revascularization, stroke, or stent thrombosis. Angiographic complications included perforation in 2%, slow-flow in 4%, and flow-limiting dissection in 0%. Significant bradycardia was uncommon during orbital atherectomy. Performing orbital atherectomy without a temporary pacemaker appears to be safe.

  18. Embolic Protection using the WIRION Embolic Protection System with JetStream Atherectomy in a Patient with Superficial Femoral Artery Chronic total Occlusion.

    PubMed

    Shammas, Nicolas W

    2017-06-01

    Distal embolization is a common occurrence with peripheral arterial interventions and is more frequent with the use of atherectomy devices. We report the first case of JetStream atherectomy (Boston Scientific, Maple Grove, MN) with the use of the novel WIRION embolic protection system filter. The procedure was performed successfully with no distal embolizations beyond the filter and with no complications in the delivery or retrieval of the filter. The pros and cons of the off label use of this filter with JetStream atherectomy are discussed.

  19. Comparison of in-hospital and follow-up results of directional atherectomy and stenting for ostial lesions of the left anterior descending coronary artery.

    PubMed

    Gambhir, D S; Batra, R; Singh, S; Sudha, R; Trehen, V; Arora, R

    1998-01-01

    Lesions at the ostium of the left anterior descending coronary artery constitute a distinct group because of suboptimal results and higher restenosis rate after balloon angioplasty. Several non-balloon devices have been used to improve the outcome of dilatation of such lesions. We retrospectively compared the in-hospital and follow-up results of directional coronary artherectomy and stents for the treatment of ostial lesions of the left anterior descending artery. Out of 37 patients, 12 underwent directional coronary atherectomy and 25, stent implantation. The two strategies were deployed at different periods over the past five years. The baseline clinical and angiographic characteristics were comparable in the two groups. Directional coronary atherectomy was done using 7Fr atherocath with adjunctive balloon angioplasty in all. All the stents were deployed using moderate to high pressure balloon inflation after adequate predilatation. While the pre-procedure luminal diameter stenosis was similar in the two groups (87.3 +/- 8.8% vs 89.3 +/- 7.2%; p = NS), the residual stenosis was significantly lower in the stent group (5 +/- 2.8%) compared to directional coronary atherectomy (18.7 +/- 9.8; p = 0.02). There was no significant difference in the primary success rate between the two devices (91.6% directional coronary atherectomy vs 100% stent; p = NS). One patient in the directional coronary atherectomy group developed acute closure followed by emergency coronary artery bypass graft surgery and death. No major complication was observed in the stent group. Over a mean follow-up of 9.9 +/- 11.6 months following directional coronary atherectomy and 8.6 +/- 4.4 months after stenting, significantly higher number of patients (60%) developed recurrence of angina or any event following directional coronary atherectomy compared to stent (15.8%; p < 0.02). There was no myocardial infarction, coronary artery bypass graft surgery or death in either group on follow-up. The need for target lesion revascularisation was significantly higher in the directional coronary atherectomy group (50%) compared to stenting (10.5%; p < 0.02). Comparing directional coronary atherectomy with stent, the event-free survival was 80 percent vs 94.7 percent at three months and 50 percent vs 84.7 percent, both at six and nine months, respectively. In conclusion, stenting of the left anterior descending artery ostial lesion results in a significantly lesser post-procedure residual stenosis, improved in-hospital outcome, a lesser need for target lesion revascularisation and much improved event-free survival on follow-up as compared to directional coronary atherectomy. Therefore, stenting appears to be a more favourable treatment option compared to directional coronary atherectomy for the treatment of ostial lesions in the left anterior descending artery.

  20. Late presenting, contained rupture of the superficial femoral artery following atherectomy and stenting: case report and literature review.

    PubMed

    Clegg, Stacey; Aghel, Arash; Rogers, R Kevin

    2014-08-01

    Excisional atherectomy alone or followed by stenting is considered an appropriate treatment strategy for patients with lifestyle-limiting claudication due to obstructive infra-inguinal peripheral arterial disease (Ramaiah et al., J Endovasc Ther 2006;13:592-6021). We present a case of a 69-year-old man with eccentric severely calcified disease of the superficial femoral artery (SFA) treated with excisional atherectomy followed by stenting with an interwoven nitinol stent. The procedure was complicated by extravascular stent migration associated with a contained rupture presenting 30 days after the intervention. The complication was successfully treated with a stent graft. Although rare, pseudoaneurysms have been reported at the site of prior atherectomy; however, this case is the first description of a contained rupture post atherectomy associated with erosion of a nitinol stent into an extra-luminal position. The mechanism and management of this complication are discussed. © 2014 Wiley Periodicals, Inc.

  1. Maximizing Lumen Gain With Directional Atherectomy.

    PubMed

    Stanley, Gregory A; Winscott, John G

    2016-08-01

    To describe the use of a low-pressure balloon inflation (LPBI) technique to delineate intraluminal plaque and guide directional atherectomy in order to maximize lumen gain and achieve procedure success. The technique is illustrated in a 77-year-old man with claudication who underwent superficial femoral artery revascularization using a HawkOne directional atherectomy catheter. A standard angioplasty balloon was inflated to 1 to 2 atm during live fluoroscopy to create a 3-dimensional "lumenogram" of the target lesion. Directional atherectomy was performed only where plaque impinged on the balloon at a specific fluoroscopic orientation. The results of the LPBI technique were corroborated with multimodality diagnostic imaging, including digital subtraction angiography, intravascular ultrasound, and intra-arterial pressure measurements. With the LPBI technique, directional atherectomy can routinely achieve <10% residual stenosis, as illustrated in this case, thereby broadly supporting a no-stent approach to lower extremity endovascular revascularization. © The Author(s) 2016.

  2. Jetstream Atherectomy System treatment of femoropopliteal arteries: Results of the post-market JET Registry.

    PubMed

    Gray, William A; Garcia, Lawrence A; Amin, Ali; Shammas, Nicolas W

    2017-12-27

    To report on procedural, safety, and effectiveness outcomes of real-world practice with the Jetstream rotational atherectomy system for treatment of femoropopliteal artery lesions. Safety and effectiveness of treatment with the Jetstream device has been demonstrated in clinical trials, but outcomes during real-world clinical practice have yet to be examined. 241 patients (66% male, mean age 67years, 41% diabetes; Rutherford 1-3) with de novo or restenotic (non-stent) femoropopliteal lesions ≥4cm in length were recruited. Major adverse events (MAE), defined as amputation, death, target lesion/vessel revascularization (TLR/TVR), myocardial infarction, or angiographic distal embolization that required a separate intervention; and binary restenosis were assessed at 30days and 12months. The mean (±SD) lesion length was 16.4±13.6cm; 35% of patients received adjunctive stents. Procedural success was achieved for 98.3% of lesions. The 30-day MAE rate was 2% (5/219; 2 TLR/TVR and 3 distal embolization); there were no deaths, index limb amputations, or myocardial infarctions. At 12months, the overall estimated freedom from TLR/TVR was 81.7% and 77.2% (44/57) of patients were free from duplex ultrasound-assessed restenosis. Efficacy and patency in a diabetic subset were similar to those of the overall cohort, while maintaining a similar safety profile. In a cohort reflecting real-world practice, the Jetstream Atherectomy System demonstrated a high procedural success rate with a low rate of complications and reinterventions, especially given the relatively long lesions studied. Copyright © 2017. Published by Elsevier Inc.

  3. Treatment of an ostial and a bifurcation lesion with a new directional atherectomy device

    PubMed Central

    Favero, L; Simpson, J B; Reimers, B

    2004-01-01

    Two cases of directional coronary atherectomy performed with a new 8 French monorail device for selective plaque excision are illustrated. This report underlines the technical characteristics of this new device, which allows the negotiation of complex coronary anatomy and emphasises the potential utility of directional coronary atherectomy in bifurcation and ostial lesions. PMID:15253988

  4. Endovascular Revascularization of Symptomatic Infrapopliteal Arteriosclerotic Occlusive Disease: Comparison of Atherectomy and Angioplasty

    PubMed Central

    Tan, Tze-Woei; Semaan, Elie; Nasr, Wael; Eberhardt, Robert T.; Hamburg, Naomi; Doros, Gheorghe; Rybin, Denis; Shaw, Palma M.; Farber, Alik

    2011-01-01

    The preferred method for revascularization of symptomatic infrapopliteal arterial occlusive disease (IPAD) has traditionally been open vascular bypass. Endovascular techniques have been increasingly applied to treat tibial disease with mixed results. We evaluated the short-term outcome of percutaneous infrapopliteal intervention and compared the different techniques used. A retrospective analysis of consecutive patients undergoing endovascular treatment for infrapopliteal arterial occlusive lesions between 2003 and 2007 in a tertiary teaching hospital was performed. Patient demographic data, indication for intervention, and periprocedural complications were recorded. Periprocedural and short-term outcomes were measured and compared. Forty-nine infrapopliteal arteries in 35 patients were treated. Twenty vessels (15 patients) underwent angioplasty and 29 vessels (20 patients) were treated with atherectomy. Demographic and angiographic characteristics were similar between the groups. Twenty-six patients had concurrent femoral and/or popliteal artery interventions. Overall, technical success was 90% and similar between angioplasty and atherectomy groups (85% versus 93%, p = NS). The vessel-specific complication rate was 10% and was similar between both groups (angioplasty 5% versus atherectomy 14%, p = NS). One dissection occurred in the angioplasty group; one perforation and three thromboembolic events occurred in the atherectomy group. Limb salvage and freedom from reintervention at 6 months were 81% and 68%, respectively, and were not significantly different between the angioplasty and atherectomy groups. Endovascular intervention for IPAD had acceptable periprocedural and short-term success rates in our high-risk patient population. Both atherectomy and angioplasty can be used successfully to treat symptomatic IPAD. PMID:22532766

  5. Calcification Remodeling Index Characterized by Cardiac CT as a Novel Parameter to Predict the Use of Rotational Atherectomy for Coronary Intervention of Lesions with Moderate to Severe Calcification

    PubMed Central

    Yu, Mengmeng; Li, Yuehua; Li, Wenbin; Lu, Zhigang; Wei, Meng

    2017-01-01

    Objective To assess the feasibility of calcification characterization by coronary computed tomography angiography (CCTA) to predict the use of rotational atherectomy (RA) for coronary intervention of lesions with moderate to severe calcification. Materials and Methods Patients with calcified lesions treated by percutaneous coronary intervention (PCI) who underwent both CCTA and invasive coronary angiography were retrospectively included in this study. Calcification remodeling index was calculated as the ratio of the smallest vessel cross-sectional area of the lesion to the proximal reference luminal area. Other parameters such as calcium volume, regional Agatston score, calcification length, and involved calcium arc quadrant were also recorded. Results A total of 223 patients with 241 calcified lesions were finally included. Lesions with RA tended to have larger calcium volume, higher regional Agatston score, more involved calcium arc quadrants, and significantly smaller calcification remodeling index than lesions without RA. Receiver operating characteristic curve analysis revealed that the best cutoff value of calcification remodeling index was 0.84 (area under curve = 0.847, p < 0.001). Calcification remodeling index ≤ 0.84 was the strongest independent predictor (odds ratio: 251.47, p < 0.001) for using RA. Conclusion Calcification remodeling index was significantly correlated with the incidence of using RA to aid PCI. Calcification remodeling index ≤ 0.84 was the strongest independent predictor for using RA prior to stent implantation. PMID:28860893

  6. Efficacy of the RADPAD protective drape during real world complex percutaneous coronary intervention procedures.

    PubMed

    Murphy, John C; Darragh, Karen; Walsh, Simon J; Hanratty, Colm G

    2011-11-15

    The RADPAD is a lead-free surgical drape containing bismuth and barium that has been demonstrated to reduce scatter radiation exposure to primary operators during fluoroscopic procedures. It is not known to what degree the RADPAD reduces radiation exposure in operators who perform highly complex percutaneous coronary intervention (PCI) requiring prolonged fluoroscopic screening times. Sixty consecutive patients due to undergo elective complex PCI involving rotational atherectomy, multivessel PCI, or chronic total occlusions were randomized in a 1:1 pattern to have their procedures performed with and without the RADPAD drape in situ. Dosimetry was performed on the left arm of the primary operator. There were 40 cases of chronic total occlusion, including 28 with contralateral injections; 15 cases involving rotational atherectomy; and 5 cases of multivessel PCI. There was no significant difference in screening times or dose-area products between the 2 patient groups. Primary operator radiation dose relative to screening time (RADPAD: slope = 1.44, R² = 0.25; no RADPAD: slope = 4.60, R² = 0.26; analysis of covariance F = 4.81, p = 0.032) and dose-area product (RADPAD: slope = 0.003, R² = 0.26; no RADPAD: slope = 0.011, R² = 0.52; analysis of covariance F = 12.54, p = 0.008) was significantly smaller in the RADPAD cohort compared to the no-RADPAD group. In conclusion, the RADPAD significantly reduces radiation exposure to primary operators during prolonged, complex PCI cases. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Rotational atherectomy before paclitaxel-eluting stent implantation in complex calcified coronary lesions: Two-year clinical outcome of the randomized ROTAXUS trial.

    PubMed

    de Waha, Suzanne; Allali, Abdelhakim; Büttner, Heinz-Joachim; Toelg, Ralph; Geist, Volker; Neumann, Franz-Josef; Khattab, Ahmed A; Richardt, Gert; Abdel-Wahab, Mohamed

    2016-03-01

    In the randomized ROTAXUS trial, routine lesion preparation of complex calcified coronary lesions using rotational atherectomy (RA) prior to paclitaxel-eluting stent implantation did not reduce the primary endpoint of angiographic late lumen loss at 9 months compared to stenting without RA. So far, no long-term data of prospective head-to-head comparisons between both treatment strategies have been reported. ROTAXUS randomly assigned patients with complex calcified coronary lesions to RA followed by stenting (n = 120) or stenting without RA (n = 120). The primary endpoint of the current analysis was the occurrence of major adverse cardiac events (MACE) at 2-year follow-up defined as the composite of death, myocardial infarction, and target vessel revascularization (TVR). At 2 years, MACE occurred in 32 patients in the RA group and 37 patients in the standard therapy group (29.4% vs. 34.3%, P = 0.47). The rates of death (8.3% vs. 7.4%, P = 1.00), myocardial infarction (8.3% vs. 6.5%, P = 0.80), target lesion revascularization (TLR, 13.8% vs. 16.7%, P = 0.58), and TVR (19.3% vs. 22.2%, P = 0.62) were similar in both groups. Despite high rates of initial angiographic success, nearly one third of patients enrolled in ROTAXUS experienced MACE within 2-year follow-up, with no differences between patients treated with or without RA. © 2015 Wiley Periodicals, Inc.

  8. Atherectomy in Peripheral Artery Disease: A Review.

    PubMed

    Bhat, Tariq M; Afari, Maxwell E; Garcia, Lawrence A

    2017-04-01

    Peripheral arterial disease (PAD) is a clinical manifestation of systemic atherosclerosis and is associated with significant morbidity and mortality. The physiological force and shear stress from angioplasty and stenting have made PAD treatment challenging. Atherectomy devices have continued to emerge as a major therapy in the management of peripheral vascular disease. This article presents a review of the current literature for the atherectomy devices used in PAD.

  9. Percutaneous Coronary Intervention in Severely Calcified Unprotected Left Main Coronary Artery Disease: Initial Experience With Orbital Atherectomy.

    PubMed

    Lee, Michael S; Shlofmitz, Evan; Kaplan, Barry; Shlofmitz, Richard

    2016-04-01

    We report the clinical outcomes of patients who underwent percutaneous coronary intervention (PCI) with orbital atherectomy for severely calcified unprotected left main coronary artery (ULMCA) disease. Although surgical revascularization is the gold standard for patients with ULMCA disease, not all patients are candidates for this. PCI is increasingly used to treat complex coronary artery disease, including ULMCA disease. The presence of severely calcified lesions increases the complexity of PCI. Orbital atherectomy can be used to facilitate stent delivery and expansion in severely calcified lesions. The clinical outcomes of patients treated with orbital atherectomy for severely calcified ULMCA disease have not been reported. From May 2014 to July 2015, a total of 14 patients who underwent PCI with orbital atherectomy for ULMCA disease were retrospectively evaluated. The primary endpoint was major cardiac and cerebrovascular event (cardiac death, myocardial infarction, stroke, and target-lesion revascularization) at 30 days. The mean age was 78.2 ± 5.8 years. The mean ejection fraction was 41.8 ± 19.8%. Distal bifurcation disease was present in 9 of 14 patients. Procedural success was achieved in all 14 patients. The 30-day major adverse cardiac and cerebrovascular event rate was 0%. One patient had coronary dissection that was successfully treated with stenting. No patient had perforation, slow flow, or thrombosis. Orbital atherectomy in patients with severely calcified ULMCA disease is feasible, even in high-risk patients who were considered poor surgical candidates. Randomized trials are needed to determine the role of orbital atherectomy in ULMCA disease.

  10. Atherectomy of the femoropopliteal artery: a systematic review and meta-analysis of randomized controlled trials.

    PubMed

    Diamantopoulos, A; Katsanos, K

    2014-10-01

    A systematic review was performed to provide a qualitative analysis and quantitative data synthesis of randomized controlled trials (RCTs) assessing debulking atherectomy versus balloon angioplasty for treatment of femoropopliteal artery occlusive disease. PubMed (MEDLINE), EMBASE, AMED, Scopus, online content and meeting abstracts were searched in May 2014 for eligible RCTs following the PRISMA selection process. Risk of bias was assessed using the Cochrane Collaboration's tool. Pooled risks were calculated with a random effects model to account for clinical and conceptual heterogeneity. Sensitivity analysis was employed to test the robustness of the results. Six RCTs comprising 287 patients (328 lesions) treated with either debulking atherectomy or balloon angioplasty for femoropopliteal artery disease were analyzed and synthesized. Technical success was similar between the atherectomy and the angioplasty group (93.6% vs. 96.2%, RR: 0.99. 95%CI: 0.95-1.03, P=0.57, I(2)=0%). Need for bail-out stenting and distal arterial embolization were largely similar between atherectomy and balloon angioplasty alone. After a median follow-up of 9 months the 2 groups showed similar primary patency (RR: 0.90, 95%CI: 0.56-1.46, P=0.68, I(2)=69%). Only 2 low-quality studies reported amputation and mortality rates, both of which were found significantly less in the atherectomy arms. Analysis of a limited body of low quality evidence with high risk of bias showed that debulking atherectomy of the femoropopliteal artery does not seem to confer any procedural advantage or improvement of clinical outcomes over balloon angioplasty alone.

  11. Atherectomy-Associated Complications in the Southern California Vascular Outcomes Improvement Collaborative.

    PubMed

    Azar, Yara; DeRubertis, Brian; Baril, Donald; Woo, Karen

    2018-05-01

    Atherectomy has become an increasingly utilized modality for the endovascular treatment of peripheral arterial occlusive disease. The objective of this study was to determine the incidence and risk factors for atherectomy-associated complications. A retrospective review was performed for all atherectomy procedures performed between January 2011 and December 2015 in the Southern California Vascular Outcomes Improvement Collaborative. Atherectomy was defined as laser, orbital, or excisional atherectomy. Complications were dissection, perforation, and distal embolization. Seven hundred twenty-nine atherectomy procedures were performed at 7 institutions by 27 practitioners. The mean age was 73 years with 415 (57%) males. Four hundred nineteen (57%) were diabetic, 673 (92%) hypertensive, 457 (63%) smokers, and 244 (34%) had coronary artery disease. Dissection occurred in 51 (7%) procedures, embolization in 23 (3.1%), and perforation in 12 (1.6%). The mean number of lesions treated per artery was the same at 1.6 in patients with any complication and no complication (P = 0.77). The total occluded length was 7.4 cm for complications versus 7.2 cm for no complication (P = 0.73). The total treated length was 12.9 cm for complications versus 11.3 cm for no complication (P = 0.03). The incidence of complications for Trans-Atlantic Inter-Society Consensus (TASC) C/D lesions were 13% compared to 10% for TASC A/B lesions (P = 0.05). The incidence of complications in superficial femoral/popliteal lesions was 12.9% vs. 10.4% in tibial lesions (P = 0.13). In multivariable analysis, treatment length was associated with a small increased risk of complication (odds ratio = 1.02, 95% confidence interval = 1.0-1.04). Increased treatment length is associated with an increased risk of atherectomy-associated complications. Demographic factors and comorbidities were not predictors of complications. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Rotational and aspiration atherectomy for infrainguinal in-stent restenosis.

    PubMed

    Beschorner, Ulrich; Krankenberg, Hans; Scheinert, Dierk; Sievert, Horst; Tübler, Thilo; Sixt, Sebastian; Noory, Elias; Rastan, Aljoscha; Macharzina, Roland; Zeller, Thomas

    2013-03-01

    To report feasibility and safety of the Pathway PV™ Atherectomy System during percutaneous peripheral vascular interventions of in-stent restenosis. 33 patients (66.7 % men; mean age 68.7 years; 39.4 % diabetics) with symptomatic infrainguinal in-stent restenosis were enrolled at 5 study sites. Primary study endpoint was the 30-day serious adverse event (SAE) rate. At one study site a subgroup of 13 patients was scheduled for additional follow-up examinations with duplex. Forty lesions with a mean lesion length of 85.7 mm (range 6 - 370 mm) were treated including total occlusions (20 %) and infrapopliteal lesions (5 %). In sixteen target lesions (40 %) procedural success was reached with atherectomy alone, 23 lesions (57.5 %) received adjunctive percutaneous transluminal angioplasty to obtain a sufficient angiographic result. Freedom from device-related SAEs was 100 %. Overall there were 11 unexpected adverse events in 11 patients, two of which were serious (retroperitoneal bleeding and access site infection). The ankle-brachial index increased significantly from 0.65 ± 0.13 at baseline to 0.82 ± 0.15 at 30 days. Mean Rutherford category improved from 2.8 ± 0.7 at baseline to 1.0 ± 1.2. In the subgroup with longer follow- up primary patency was 33 % after 12 months and 25 % after 24 months. Secondary patency was 92 % after 12 and 24 months. The use of the Pathway PV™ System during percutaneous peripheral vascular interventions of in-stent restenosis appears to be feasible and safe but does not seem to offer a sustainable solution regarding long term patency. A combination with drug eluting balloon angioplasty could be an interesting option and should be evaluated in further clinical trials.

  13. [Atherectomy for peripheral arterial disease].

    PubMed

    Londero, Louise Skovgaard; Høgh, Annette Langager; Lindholt, Jes Sanddal

    2015-04-13

    Symptomatic peripheral arterial disease is managed according to national and international guidelines and the number of vascular reconstructions performed each year has increased over the past decade mainly due to an increasing frequency of endovascular procedures. Atherectomy as an alternative to the established treatment of symptomatic peripheral arterial disease has recently been analysed in a Cochrane review. In Denmark, atherectomy is not performed and so far the evidence is poor as the method is not an alternative to the established treatment in this country.

  14. Treating peripheral arterial disease percutaneously with atherectomy.

    PubMed

    Schwartz, Bryan G; Kloner, Robert A; Burstein, Steven; Economides, Christina; Mayeda, Guy S

    2012-06-01

    To determine clinical outcomes of patients who underwent percutaneous revascularization (PR) with multiple devices. PR cases at a private, tertiary referral hospital were reviewed retrospectively. Limb salvage and patency rates were calculated by the Kaplan Meier method. Historical and procedural factors were analyzed by multivariate Cox proportional hazards models. We identified 66 patients and 87 limbs with 261 lesions, including 38 patients with critical limb ischemia (CLI) (51 limbs, 171 lesions). PR incorporated multiple devices (2.0 ± 1.2 devices/lesion, 2.4 ± 1.6 devices/procedure), including balloon angioplasty (57%), excisional atherectomy (54%), orbital atherectomy (44%), and stenting (13%). Last imaged patency was at 18 ± 13 months and last clinical follow-up was 22 ± 12 months. Thirty-five of 87 limbs had ≥1 repeat PR. In 51 limbs with CLI, limb salvage was 75% at 3 years. Independent predictors of amputation were higher creatinine (P=.01; hazard ratio [HR], 1.4), Rutherford category (P=.03; HR, 3.5), and history of coronary artery bypass graft (CABG) (P=.03; HR, 8.9). Overall patency remained 75% through 3 years. Loss of patency or primary patency (patency without repeat PR) was predicted by higher creatinine, Rutherford category, chronic total occlusion, history of CABG, female gender, current and past smoking. Use of excisional atherectomy maintained overall patency (P=.01; HR, 0.36). An aggressive approach to PR with frequent use of atherectomy resulted in high rates of limb salvage and patency. Smoking cessation and excisional atherectomy may improve patency rates.

  15. Peripheral atherectomy practice patterns in the United States from the Vascular Quality Initiative.

    PubMed

    Mohan, Sathish; Flahive, Julie M; Arous, Edward J; Judelson, Dejah R; Aiello, Francesco A; Schanzer, Andres; Simons, Jessica P

    2018-06-21

    Peripheral atherectomy has been shown to have technical success in single-arm studies, but clinical advantages over angioplasty and stenting have not been demonstrated, leaving its role unclear. We sought to describe patterns of atherectomy use in a real-world U.S. cohort to understand how it is currently being applied. The Vascular Quality Initiative was queried to identify all patients who underwent peripheral vascular intervention from January 2010 to September 2016. Descriptive statistics were performed to analyze demographics of the patients, comorbidities, indication, treatment modalities, and lesion characteristics. The intermittent claudication (IC) and critical limb ischemia (CLI) cohorts were analyzed separately. Of 85,605 limbs treated, treatment indication was IC in 51% (n = 43,506) and CLI in 49% (n = 42,099). Atherectomy was used in 15% (n = 13,092) of cases, equivalently for IC (15%; n = 6674) and CLI (15%; n = 6418). There was regional variation in use of atherectomy, ranging from a low of 0% in one region to a high of 32% in another region. During the study period, there was a significant increase in the proportion of cases that used atherectomy (11% in 2010 vs 18% in 2016; P < .0001). Compared with nonatherectomy cases, those with atherectomy use had higher incidence of prior peripheral vascular intervention (IC, 55% vs 43% [P < .0001]; CLI, 47% vs 41% [P < .0001]), greater mean number of arteries treated (IC, 1.8 vs 1.6 [P < .0001]; CLI, 2.1 vs 1.7 [P < .0001]), and lower proportion of prior leg bypass (IC, 10% vs 14% [P < .0001]; CLI, 11% vs 17% [P < .0001]). There was lower incidence of failure to cross the lesion (IC, 1% vs 4% [P < .0001]; CLI, 4% vs 7% [P < .0001]) but higher incidence of distal embolization (IC, 1.9% vs 0.8% [P < .0001]; CLI, 3.0% vs 1.4% [P < .0001]) and, in the CLI cohort, arterial perforation (1.4% vs 1.0%; P = .01). Despite a lack of evidence for atherectomy over angioplasty and stenting, its use has increased across the United States from 2010 to 2016. It is applied equally to IC and CLI populations, with no identifiable pattern of comorbidities or lesion characteristics, suggesting that indications are not clearly delineated or agreed on. This study places impetus on further understanding of the optimal role for atherectomy and its long-term clinical benefit in the management of peripheral arterial disease. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  16. Successful Use of Orbital Atherectomy as an Adjunct in Treating Extensively Calcified Mesenteric Artery Lesions.

    PubMed

    Richard, Michele; Krol, Emilia; Dietzek, Alan

    2016-10-01

    To describe the use of orbital technique of atherectomy as an adjunct to successful angioplasty and stent placement of the superior mesenteric artery (SMA). The technique is demonstrated in a 68-year-old man with critical SMA stenosis. The SMA was cannulated with 0.014-in wire, but the lesion was highly stenotic and densely calcified and prevented the passage of even the smallest 1.5-mm balloon. Orbital atherectomy was thus performed with a 1.25-mm CSI crown. Balloon angioplasty was then possible with a 4 mm × 2 cm balloon followed by placement of a 7 mm × 22 mm balloon-mounted stent. The use of atherectomy as an adjunct to angioplasty and stenting in extensive, calcified SMA lesions supports the value of this technique to avoid a much larger and morbid open procedure. Published by Elsevier Inc.

  17. Gender-Based Differences in Outcomes After Orbital Atherectomy for the Treatment of De Novo Severely Calcified Coronary Lesions.

    PubMed

    Lee, Michael S; Shlofmitz, Evan; Mansourian, Pejman; Sethi, Sanjum; Shlofmitz, Richard A

    2016-11-01

    We evaluated the relationship between gender and angiographic and clinical outcomes in patients with severely calcified lesions who underwent orbital atherectomy. Female gender is associated with increased risk of adverse clinical events after percutaneous coronary intervention (PCI). Severe coronary artery calcification increases the complexity of PCI and increases the risk of adverse cardiac events. Orbital atherectomy is effective in plaque modification, which facilitates stent delivery and expansion. Whether gender differences exist after orbital atherectomy is unclear. Our analysis retrospectively analyzed 458 consecutive real-world patients (314 males and 144 females) from three centers who underwent orbital atherectomy. The primary endpoint was the major adverse cardiac and cerebrovascular event (MACCE) rate, defined as the composite of death, myocardial infarction (MI), target-vessel revascularization (TVR), and stroke, at 30 days. The primary endpoint of MACCE was low and similar in females and males (0.7% vs 2.9%; P=.14). The individual endpoints of death (0.7% vs 1.6%; P=.43), MI (0.7% vs 1.3%; P=.58), TVR (0% vs 0%; P>.99), and stroke (0% vs 0.3%; P=.50) were low in both groups and did not differ. Angiographic complications were low: perforation (0.8% vs 0.7%; P>.90), dissection (0.8% vs 1.1%; P=.80), and no-reflow (0.8% vs 0.7%; P>.90). Plaque modification with orbital atherectomy was safe and provided similar angiographic and clinical outcomes between females and males. Randomized trials with longer-term follow-up are needed to support our results.

  18. Real‐World Multicenter Registry of Patients with Severe Coronary Artery Calcification Undergoing Orbital Atherectomy

    PubMed Central

    Shlofmitz, Evan; Kaplan, Barry; Alexandru, Dragos; Meraj, Perwaiz; Shlofmitz, Richard

    2016-01-01

    Objectives We evaluated the safety and efficacy of orbital atherectomy in real‐world patients with severe coronary artery calcification (CAC). Background The presence of severe CAC increases the complexity of percutaneous coronary intervention as it may impede stent delivery and optimal stent expansion. Atherectomy may be an indispensable tool for uncrossable or undilatable lesions by modifying severe CAC. Although the ORBIT I and II trials report that orbital atherectomy was safe and effective for the treatment of severe CAC, patients with kidney disease, recent myocardial infarction, long diffuse disease, severe left ventricular dysfunction, and unprotected left main disease were excluded. Methods This retrospective study included 458 consecutive patients with severe CAC who underwent orbital atherectomy followed by stenting from October 2013 to December 2015 at 3 centers. Results The primary endpoint of major adverse cardiac and cerebrovascular events at 30 days was 1.7%. Low rates of 30‐day all‐cause mortality (1.3%), myocardial infarction (1.1%), target vessel revascularization (0%), stroke (0.2%), and stent thrombosis (0.9%) were observed. Angiographic complications were low: perforation was 0.7%, dissection 0.9%, and no‐reflow 0.7%. Emergency coronary artery bypass graft surgery was performed in 0.2% of patients. Conclusion In the largest real‐world study of patients who underwent orbital atherectomy, including high‐risk patients who were not surgical candidates as well as those with very complex coronary anatomy, acute and short‐term adverse clinical event rates were low. A randomized clinical trial is needed to identify the ideal treatment strategy for patients with severe CAC. PMID:27358246

  19. Coronary Atherectomy in the United States (from a Nationwide Inpatient Sample).

    PubMed

    Arora, Shilpkumar; Panaich, Sidakpal S; Patel, Nilay; Patel, Nileshkumar J; Savani, Chirag; Patel, Samir V; Thakkar, Badal; Sonani, Rajesh; Jhamnani, Sunny; Singh, Vikas; Lahewala, Sopan; Patel, Achint; Bhatt, Parth; Shah, Harshil; Jaiswal, Radhika; Gupta, Vishal; Deshmukh, Abhishek; Kondur, Ashok; Schreiber, Theodore; Badheka, Apurva O; Grines, Cindy

    2016-02-15

    Contemporary real-world data on clinical outcomes after utilization of coronary atherectomy are sparse. The study cohort was derived from Healthcare Cost and Utilization Project Nationwide Inpatient Sample database from year 2012. Percutaneous coronary interventions including atherectomy were identified using appropriate International Classification of Diseases, 9th Revision diagnostic and procedural codes. Two-level hierarchical multivariate mixed models were created. The primary outcome was a composite of in-hospital mortality and periprocedural complications; the secondary outcome was in-hospital mortality. Hospitalization costs were also assessed. A total of 107,131 procedures were identified in 2012. Multivariate analysis revealed that atherectomy utilization was independently predictive of greater primary composite outcome of in-hospital mortality and complications (odds ratio 1.34, 95% confidence interval 1.22 to 1.47, p <0.001) but was not associated with any significant difference in terms of in-hospital mortality alone (odds ratio 1.22, 95% confidence interval 0.99 to 1.52, p 0.063). In the propensity-matched cohort, atherectomy utilization was again associated with a higher rate of complications (12.88% vs 10.99%, p = 0.001), in-hospital mortality +a ny complication (13.69% vs 11.91%, p = 0.003) with a nonsignificant difference in terms of in-hospital mortality alone (3.45% vs 2.88%, p = 0.063) and higher hospitalization costs ($25,341 ± 353 vs $21,984 ± 87, p <0.001). Atherectomy utilization during percutaneous coronary intervention is associated with a higher rate of postprocedural complications without any significant impact on in-hospital mortality. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Clinical predictors of mortality following rotational atherectomy and stent implantation in high‐risk patients: A single center experience

    PubMed Central

    Édes, István F.; Ruzsa, Zoltán; Szabó, György; Nardai, Sándor; Becker, Dávid; Benke, Kálmán; Szilveszter, Bálint

    2015-01-01

    Objectives Our aim was to assess the procedural success and determine the clinical predictors of postprocedure mortality, following rotational atherectomy (RA) and stenting in high‐risk patients. Background RA is mainly used to facilitate stenting in complex lesions. Outcomes involving RA and stenting have been investigated, yet high‐risk patients have not been adequately described. Methods Data of 218 consecutive patients who underwent RA were evaluated in a prospective register. Primary endpoints were the angiographic success and long‐term mortality. Secondary endpoints were procedural success, consumption of the angioplasty equipment, and periprocedural major adverse cardiac events. The impact of the relevant angiographic and clinical characteristics on long‐term mortality was analyzed using uni‐ and multivariate Cox regression analysis. Results Mean age of the patients was 70 ± 8.2 years, diabetes was present in 44%, and chronic renal failure in 29%. Prior myocardial infarction and three‐vessel disease amounted to 42.2% and 32.6%, respectively. Altogether, 52.8% of patients underwent RA after a failed, non‐RA intervention attempt, and 30.7% of cases presented as acute coronary syndromes. Angiographic success was 100%, and all patients received stents after RA. Periprocedural major adverse cardiac events occurred in five (2.3%) patients. Postprocedural death was investigated, with a mean follow‐up of 36 months. Mortality amounted to 37.2%. Multivariate analysis revealed that left ventricular ejection fraction < 50%, glomerular filtration rate < 60 ml/min, cardiogenic shock, and diabetes were the only independent mortality predictors. Conclusions We have found that RA and stenting is feasible and viable in an elderly high‐risk population, with exceptional procedural success and acceptable long‐term results. © 2015 Wiley Periodicals, Inc. PMID:26032270

  1. Clinical Outcomes of Patients Undergoing Rotational Atherectomy Followed by Drug-eluting Stent Implantation: A Single-center Real-world Experience

    PubMed Central

    Cuenza, Lucky R.; Jayme, Ada Cherryl; Khe Sui, James Ho

    2017-01-01

    Background: Rotational atherectomy (RA) is used to improve procedural success of percutaneous catheter interventions (PCIs) of complex and heavily calcified coronary lesions. We report the clinical experience and outcomes in our institution with the use of RA, followed by drug-eluting stent implantation. Materials and Methods: Data of 81 patients treated with PCI and adjunctive RA were analyzed. Clinical follow-up for the occurrence of major adverse events (MAEs) was obtained in all patients and correlated with significant variables using multivariate Cox proportional hazards analysis. Results: Mean age was 67.9 ± 9.2 years, 61.7% had diabetes, 20.9% had chronic kidney disease, and 48.1% had previous acute coronary syndrome (ACS). Mean SYNTAX score was 29.8 ± 12.2, with a 92.5% angiographic success rate achieved. In-hospital MAEs rate was 7.4% while mortality rate was 8.6%. On median follow-up of 12.2 months, incidence of MAEs of 13.5% with a 75% free incidence from MAEs at 34 months. Multivariate analysis revealed that a history of previous ACS, ejection fraction, neutrophil to lymphocyte ratio, platelet to lymphocyte ratio, SYNTAX score, burr to artery ratio, and attainment of angiographic success were significant predictors of MAEs. Conclusion: RA followed by drug-eluting stent implantation is a safe and effective method in improving procedural success as well as short- and long-term outcomes of PCI in our center. A combination of clinical and procedural factors is predictive for the occurrence of MAEs and should be taken into account in the application of this technique. PMID:29326773

  2. Outcomes in Elderly Patients With Severely Calcified Coronary Lesions Undergoing Orbital Atherectomy.

    PubMed

    Lee, Michael S; Shlofmitz, Evan; Lluri, Gentian; Shlofmitz, Richard A

    2017-04-01

    We evaluated the clinical outcomes of elderly patients who underwent orbital atherectomy for the treatment of severe coronary artery calcification (CAC) prior to stenting. Percutaneous coronary intervention (PCI) of severe CAC is associated with worse clinical outcomes including death, myocardial infarction (MI), and target vessel revascularization (TVR). The elderly represents a high-risk group of patients, often have more comorbid conditions, and have worse outcomes after PCI compared to younger patients. Clinical trials and a large multicenter registry have demonstrated the safety and efficacy of orbital atherectomy for the treatment of severe CAC. Clinical outcomes of elderly patients who undergo orbital atherectomy are unknown. Of the 458 patients, 229 were ≥75 years old (elderly) and 229 were <75 years old (younger). The primary endpoint was rate of 30-day major adverse cardiac and cerebrovascular events (MACCE), comprised of cardiac death, MI, TVR, and stroke. The primary endpoint was similar in the elderly and younger groups (2.2% vs. 2.2%, P = 1), as were the individual endpoints of death (2.2% vs. 0.4%, P = 0.1), MI (0.9% vs. 1.3%, P = 0.65), TVR (0% vs. 0%, P = 1), and stroke (0% vs. 0.4%, P = 0.32). The rates of angiographic complications and stent thrombosis were similarly low in both groups. The elderly represented a sizeable number of patients who underwent orbital atherectomy. It is a safe and effective treatment strategy for elderly patients with severe CAC as the clinical outcomes were similar to their younger counterparts. A randomized trial should further clarify the role of orbital atherectomy in these patients. © 2017, Wiley Periodicals, Inc.

  3. Outcomes After Orbital Atherectomy of Severely Calcified Left Main Lesions: Analysis of the ORBIT II Study.

    PubMed

    Lee, Michael S; Shlofmitz, Evan; Shlofmitz, Richard; Sahni, Sheila; Martinsen, Brad; Chambers, Jeffrey

    2016-09-01

    The ORBIT II trial reported excellent outcomes in patients with severely calcified coronary lesions treated with orbital atherectomy. Severe calcification of the left main (LM) artery represents a complex coronary lesion subset. This study evaluated the safety and efficacy of coronary orbital atherectomy to prepare severely calcified protected LM artery lesions for stent placement. The ORBIT II trial was a prospective, multicenter clinical trial that enrolled 443 patients with severely calcified coronary lesions in the United States. The major adverse cardiac event (MACE) rate through 2 years post procedure, defined by cardiac death, myocardial infarction (CK-MB >3x upper limit of normal with or without a new pathologic Q-wave) and target-vessel revascularization, was compared in the LM and non-left main (NLM) groups. Among the 443 patients, a total of 10 underwent orbital atherectomy of protected LM artery lesions. At 2 years, there was no significant difference in the 2-year MACE rate in the LM and NLM groups (30.0% vs 19.1%, respectively; P=.36). Cardiac death was low in both groups (0% vs 4.4%, respectively; P=.99). Myocardial infarction occurred within 30 days in both groups (10.0% vs 9.7%, respectively; P=.99). Severe dissection, perforation, persistent slow flow, and persistent no reflow did not occur in the LM group. Abrupt closure occurred in 1 patient in the LM group. Orbital atherectomy for patients with heavily calcified LM coronary artery lesions is safe and feasible. Further studies are needed to assess the safety and efficacy of orbital atherectomy in patients with severely calcified LM artery lesions.

  4. Real-World Multicenter Registry of Patients with Severe Coronary Artery Calcification Undergoing Orbital Atherectomy.

    PubMed

    Lee, Michael S; Shlofmitz, Evan; Kaplan, Barry; Alexandru, Dragos; Meraj, Perwaiz; Shlofmitz, Richard

    2016-08-01

    We evaluated the safety and efficacy of orbital atherectomy in real-world patients with severe coronary artery calcification (CAC). The presence of severe CAC increases the complexity of percutaneous coronary intervention as it may impede stent delivery and optimal stent expansion. Atherectomy may be an indispensable tool for uncrossable or undilatable lesions by modifying severe CAC. Although the ORBIT I and II trials report that orbital atherectomy was safe and effective for the treatment of severe CAC, patients with kidney disease, recent myocardial infarction, long diffuse disease, severe left ventricular dysfunction, and unprotected left main disease were excluded. This retrospective study included 458 consecutive patients with severe CAC who underwent orbital atherectomy followed by stenting from October 2013 to December 2015 at 3 centers. The primary endpoint of major adverse cardiac and cerebrovascular events at 30 days was 1.7%. Low rates of 30-day all-cause mortality (1.3%), myocardial infarction (1.1%), target vessel revascularization (0%), stroke (0.2%), and stent thrombosis (0.9%) were observed. Angiographic complications were low: perforation was 0.7%, dissection 0.9%, and no-reflow 0.7%. Emergency coronary artery bypass graft surgery was performed in 0.2% of patients. In the largest real-world study of patients who underwent orbital atherectomy, including high-risk patients who were not surgical candidates as well as those with very complex coronary anatomy, acute and short-term adverse clinical event rates were low. A randomized clinical trial is needed to identify the ideal treatment strategy for patients with severe CAC. © 2016 The Authors. Journal of Interventional Cardiology Published by Wiley Periodicals, Inc.

  5. Ubiquitous Nature of Distal Athero/Thromboembolic Events during Lower Extremity Atherectomy Procedures Involving the Superficial Femoral Artery

    PubMed Central

    Wasty, Najam; Khakwani, M. Z.; Kotev, Spas; Boiangiu, Catalin; Hasan, Omar; Anna, Manjusha; Tayal, Rajiv; Kaid, Khalil; Baker, Gail; Cohen, Marc

    2016-01-01

    This study aims to evaluate occurrence, size, composition, and clinical significance of embolized debris during superficial femoral artery atherectomy using all commercially available atherectomy devices. Distal athero/thromboembolic events (DATE) are a universal phenomenon in lower extremity atherectomy procedures (LEAPs) due to the sheer volume of atheroma and the thrombus burden in peripheral arterial disease. Some of these events can be clinically significant. We prospectively gathered clinical and histopathological data on all commercially available atherectomy devices by using embolic protection devices (EPD) in every case. After intervention, the contents of EPD were examined both microscopically and macroscopically. Data from 59 consecutive patients undergoing LEAP were analyzed. DATE occurred 100% of the time. The composition of particulate debris varied with the device used. Grossly visible agglomerated debris was captured by the filter in the majority of patients 54/59 (91.5%). Clinically significant debris, defined by the Preventing Lower Extremity Distal Embolization Using Embolic Filter Protection registry as particle diameter > 0.2 cm, was found in 33/59 (56%) patients. The size of captured debris particles ranged from 0.1 to 2.4 mm. While DATE occurred in all patients, clinically significant DATE occurred in 56% patients undergoing LEAP regardless of the atherectomy device. In spite of a large fraction of the clinically significant debris occurring on our routine dual antiplatelet regimen, no patient suffered an amputation. Although DATE was prevented by the use of EPD in all 59 cases, more data are needed to determine whether the use of EPD translates into a long-term clinical benefit. Use of EPD and optimal thromboprophylaxis should be considered in patients, especially in the setting of compromised distal runoff. PMID:27867291

  6. Alterations of Blood Flow Through Arteries Following Atherectomy and the Impact on Pressure Variation and Velocity.

    PubMed

    Plourde, Brian D; Vallez, Lauren J; Sun, Biyuan; Nelson-Cheeseman, Brittany B; Abraham, John P; Staniloae, Cezar S

    2016-09-01

    Simulations were made of the pressure and velocity fields throughout an artery before and after removal of plaque using orbital atherectomy plus adjunctive balloon angioplasty or stenting. The calculations were carried out with an unsteady computational fluid dynamic solver that allows the fluid to naturally transition to turbulence. The results of the atherectomy procedure leads to an increased flow through the stenotic zone with a coincident decrease in pressure drop across the stenosis. The measured effect of atherectomy and adjunctive treatment showed decrease the systolic pressure drop by a factor of 2.3. Waveforms obtained from a measurements were input into a numerical simulation of blood flow through geometry obtained from medical imaging. From the numerical simulations, a detailed investigation of the sources of pressure loss was obtained. It is found that the major sources of pressure drop are related to the acceleration of blood through heavily occluded cross sections and the imperfect flow recovery downstream. This finding suggests that targeting only the most occluded parts of a stenosis would benefit the hemodynamics. The calculated change in systolic pressure drop through the lesion was a factor of 2.4, in excellent agreement with the measured improvement. The systolic and cardiac-cycle-average pressure results were compared with measurements made in a multi-patient study treated with orbital atherectomy and adjunctive treatment. The agreements between the measured and calculated systolic pressure drop before and after the treatment were within 3%. This excellent agreement adds further confidence to the results. This research demonstrates the use of orbital atherectomy to facilitate balloon expansion to restore blood flow and how pressure measurements can be utilized to optimize revascularization of occluded peripheral vessels.

  7. Study to determine the clinical significance of HEmolysis During Orbital AtheRectomy (CLEAR study).

    PubMed

    Staniloae, Cezar S; Korabathina, Ravikiran; Lane, Thomas A; Dattilo, Raymond; Church, Kevin J; Mody, Kanika P; Mayeda, Guy S

    2011-02-01

    To evaluate the incidence of clinically evident hemolysis associated with orbital atherectomy used to treat severe peripheral artery disease. The observational CLEAR study enrolled 31 subjects (16 men; mean age 71 ± 10 years, range 44-92) with claudication (58.1%) or critical limb ischemia (38.7%) who underwent orbital atherectomy with the Diamondback 360 system at 4 US centers. The 42 lesions in 31 limbs were located in the superficial femoral (n = 19, 45.2%), popliteal (n = 8, 19.0%), and tibial arteries (n = 15, 35.8%). The majority of lesions (34, 81.0%) were de novo; moderate or severe calcification was identified in 90.5% of cases. Lesion and procedural parameters were analyzed at a core laboratory. Blood samples were collected during and post procedure and analyzed for markers of hemolysis. The primary endpoint was the occurrence of clinically significant hemolysis. The secondary endpoints included the occurrence of any clinical symptoms/signs potentially related to hemolysis. Statistical analysis was performed to identify predictors for hemolysis. Laboratory evidence of hemolysis was seen in 11 (35.5%) subjects. No one met the clinical event criteria, and so the primary endpoint of the study was not reached. The secondary endpoints were hypertensive crisis (1, 3.2%) and transient hemoglobinuria (3, 9.7%). Lower glomerular filtration rates, calcified plaque, long atherectomy runs, and solid crown selection were independent predictors of hemolysis. There was no clinically significant hemolysis after orbital atherectomy. The results of this study will enable users to predict conditions that predispose to high levels of red cell hemolysis following orbital atherectomy and to take appropriate measures to limit its occurrence.

  8. The disproportionate growth of office-based atherectomy.

    PubMed

    Mukherjee, Dipankar; Hashemi, Homayoun; Contos, Brian

    2017-02-01

    The purpose of this study was to evaluate the trends in procedure volume, clinical sites of care, and Medicare expenditure for peripheral vascular interventions (PVIs) for lower extremity occlusive disease since the Centers for Medicare and Medicaid Services instituted reimbursement policy changes that broadened payment for procedures performed in physician-owned office-based laboratories (OBLs). We analyzed fee-for-service Medicare claims data from 2011 to 2014 to obtain the frequency of use of PVI by type, care setting, and physician specialty. We also assessed changes in the total Medicare cost for PVI by setting. There was a 60% increase in atherectomy cases among Medicare beneficiaries between 2011 and 2014. During the same period, OBLs experienced a 298% increase in atherectomy volume vs a 27% increase in hospital outpatient settings and an 11% decrease for inpatient hospital settings. In 2014, OBLs were the most common setting for atherectomy. Nonatherectomy PVIs grew more modestly at just 3% but also experienced site of care shifts. Vascular surgeons and cardiologists accounted for the majority of office-based PVIs in 2014. Total Medicare costs for PVIs increased 18% from 2011 to 2014. Hospital inpatient costs declined 1%, whereas costs for hospital outpatient PVIs increased by 41% and physician office costs increased by 258%. The migration of revascularization procedures for lower extremity peripheral arterial occlusive disease continues from the inpatient to the outpatient setting and especially to OBLs. Increased use of atherectomy in all segments of the lower extremity arterial system has been observed, particularly in OBLs, without substantial evidence in the literature of increased efficacy compared with standard angioplasty with or without stenting. Generous Medicare reimbursement for in-office atherectomy procedures is likely contributing to the volume shifts observed. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. Longitudinal outcomes after tibioperoneal angioplasty alone compared to tibial stenting and atherectomy for critical limb ischemia.

    PubMed

    Reynolds, Shaun; Galiñanes, Edgar Luis; Dombrovskiy, Viktor Y; Vogel, Todd R

    2013-10-01

    There are limited data available evaluating longitudinal outcomes after tibioperoneal angioplasty (TA) alone compared to adjunctive tibial procedures including stenting and atherectomy. Using the Centers for Medicare & Medicaid Services inpatient claims (2005-2007), patients evaluated TA only, TA plus stent placement (TA + S), and TA plus atherectomy (TA + A). A total of 2080 patients with critical limb ischemia underwent percutaneous tibioperoneal intervention for the indication of ulceration. Procedures included TA (56.3%), TA + S (16.2%), and TA + A (27.5%). Rates of amputation were not statistically different between the groups at 30, 90, and 365 days after the intervention. Mean total hospital charges were TA ($35,867), TA + A ($41,698; P = .0004), and TA + S ($51,040; P < .0001). Patients undergoing TA alone compared to concomitant stenting or atherectomy for ulceration demonstrated no improvement in limb salvage. Future analysis of adjunctive tibioperoneal interventions is essential to temper cost, as they fail to improve long-term limb salvage.

  10. [Microscopic investigation of vessel wall after endovascular catheter atherectomy].

    PubMed

    Tsygankov, V N; Khovalkin, R G; Chekmareva, I A; Kalinin, D V; Filippova, E M

    2014-01-01

    Endovascular target catheter atherectomy (ETCA) - method of artery patency allowing to obtain occlusion substrate. Given the high destructive effect of atherectome's elements on tissue the objective was determination possibility of histological and electron microscopic investigation of this substrate after atherectomy. The research included 8 patients who underwent ETCA of legs arteries. It was observed substrate removal from broken stent in 1 case. 2 of 8 patients had diabetes. Obtained substrate was available for histological and electron microscopic investigation. Atherosclerosis was confirmed in all cases. It was not observed substrate significant morphological changes in patients with presence or absence of diabetes. Microscopic investigation of substrate from broken stent shows pronounced development of granulation tissue that was regarded as special form of reparative regeneration. Finding internal elastic membrane during microscopic investigation in some cases proves radical intervention. The authors consider that microscopic investigation of substrate after ETCA may be used for diagnosis verification, thorough analysis of morphological changes in lesion area and radicalism of atherectomy.

  11. Comparison of orbital atherectomy plus balloon angioplasty vs. balloon angioplasty alone in patients with critical limb ischemia: results of the CALCIUM 360 randomized pilot trial.

    PubMed

    Shammas, Nicolas W; Lam, Russell; Mustapha, Jihad; Ellichman, Jonathan; Aggarwala, Gaurav; Rivera, Ernesto; Niazi, Khusrow; Balar, Nilesh

    2012-08-01

    To evaluate the role of orbital atherectomy in calcified infrapopliteal arteries in patients with critical limb ischemia compared to balloon angioplasty (BA) alone. A randomized multicenter study was undertaken to evaluate short and 1-year outcomes in 50 patients (32 men; mean age 71 years, range 40-90) with confirmed calcified lesions using 1∶1 randomization to the Diamondback 360° Orbital Atherectomy System followed by BA vs. BA alone. All patients had severe (≥50% stenosis) peripheral artery disease (Rutherford classification 4-6) in the popliteal, tibial, and/or peroneal arteries. The primary endpoint was defined as restoration of a normal lumen (residual stenosis ≤30%) with no bailout stenting or dissection types C through F. Scheduled follow-up visits were conducted according to a common protocol at 1, 6, and 12 months. Procedural success was 93.1% (27/29 lesions) for atherectomy + BA patients and 82.4% (28/34 lesions) for BA alone (p = 0.27). Bailout stenting was needed in 2 (6.9%) of the 29 atherectomy + BA lesions and in 5 (14.3%) of the 35 BA-treated lesions (p = 0.44). At 1 year, there were no amputations in either group related to the index procedure. Estimates for freedom from target vessel revascularization and all-cause mortality were 93.3% and 100% in the atherectomy + BA group vs. 80.0% (p = 0.14) and 68.4% (p = 0.01) in the BA group, respectively. Proportional hazard models evaluating survival time vs. status of residual stenosis determined a hazard ratio for major adverse events of 5.6 for patients with an acute post-procedure residual stenosis >30% (p = 0.01). Debulking with orbital atherectomy appeared to increase the chance of reaching a desirable angioplasty result, with less acute need for bailout stenting and a higher procedure success. A negative association between procedure success and risk of serious adverse outcomes should encourage larger confirmatory studies.

  12. Safety and Effectiveness of the Nav-6 Filter in Preventing Distal Embolization During Jetstream Atherectomy of Infrainguinal Peripheral Artery Lesions.

    PubMed

    Banerjee, Avantika; Sarode, Karan; Mohammad, Atif; Brilakis, Emmanouil S; Banerjee, Subhash; Shammas, Gail A; Shammas, Nicolas W

    2016-08-01

    The risk of distal embolization (DE) during infrainguinal peripheral artery interventions (PAI) is often mitigated by the use of embolic protection devices. There are limited data on the use of filters with the Jetstream (JS) atherectomy device, a rotational cutter with aspiration capacity. The Nav-6 filter is uniquely suited for use with the JS due to its wire compatibility and detachment from the filter; however, data on the off-label use of this combination have not been reported. Consecutive patients between October 2008 and April 2015 undergoing endovascular infrainguinal PAI with JS were analyzed as part of the Excellence in Peripheral Artery Disease (XL-PAD) registry (NCT01904851). Patients were divided into two subgroups with Nav-6 filter use vs no filter use. Descriptive and univariate analyses were performed. Among 141 patients (mean age, 67.8 ± 10.8 years; 169 lesions) included in this study, the Nav-6 filter was used in 82 (59%). Use of a filter was more frequent in longer lesions (146 ± 106 mm vs 91 ± 72 mm; P=.01), in more severe stenoses (95% vs 87%; P=.04), and in chronic total occlusions (33% vs 8.3%; P=.01). Patients receiving filters had longer procedure duration (102 ± 51 min vs 66 ± 41 min; P=.01) and longer fluoroscopy times (31 ± 16 min vs 21 ± 10 min; P<.001). Use of the Nav-6 filter with the JS during PAI was associated with numerically lower rates of DE (1.8% vs 8%; P=.10) and similar rates of death and amputation. At 12 months, the target-lesion revascularization rate was higher in the filter group (22% vs 2.7%; P=.02), likely secondary to use of the filter in more complex lesions. Nav-6 filter during JS atherectomy was predominantly used during complex infrainguinal PAI and was associated with less occurrence of DE.

  13. Optimal use of atherectomy in critical limb ischemia.

    PubMed

    Rundback, John H; Herman, Kevin Chaim

    2014-09-01

    Critical limb ischemia (CLI) is the most severe and debilitating form of peripheral arterial disease and is associated with high rates of limb loss and cardiovascular mortality. The unique physical environment of tibial occlusive disease underlying most CLI cases limits treatment options and long-term durability, with resulting frequent rates of persistent obstruction, restenosis, and reintervention. Atherectomy represents a potential strategy to improve acute and late results when treating patients with CLI. Available atherectomy devices each have specific performance characteristics, evidentiary rationale, and limitations that mandate a clear understanding of the optimal albeit evolving use of this category of interventional tools. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. The added benefits and efficacy of atherectomy in the lower limb.

    PubMed

    VAN DEN Berg, Jos C

    2016-08-01

    Atherectomy has been used as an adjunct therapy for balloon angioplasty and/or stent placement in the superficial femoral artery for many years, but has never gained global popularity in the treatment of peripheral arterial disease, most probably related to the conflicting results as published in the literature. Novel techniques that have been developed over the past years are yielding promising results in the infrainguinal region. This paper will describe the added benefits of atherectomy as compared to plain old balloon angioplasty and bail-out bare-metal stenting, both in the treatment of primary lesions of the superficial femoral artery as well as in cases of in-stent restenosis.

  15. Revascularization of a thrombosed, previously stented aorto-renal graft using combined directional atherectomy and AngioJet thrombectomy.

    PubMed

    Seth, A; Mathur, A; Chandra, P; Aggarwal, P; Khanna, N

    1999-01-01

    We report an interesting case with bilateral PTFE aorto-renal grafts of which one graft underwent balloon angioplasty and stenting for proximal stenosis. Combined debulking by AngioJet thrombectomy and Simpsons directional atherectomy was performed within the stent following reocclusion of the graft 9 months later.

  16. Treatment of Angio-Seal-Related Femoral Artery Occlusion Using Directional Atherectomy-Primary Results and Midterm Follow-Up.

    PubMed

    Babaev, Anvar; Gokhale, Rohit; Zavlunova, Susanna; Attubato, Michael

    2016-11-01

    We describe a novel approach for the endovascular treatment of femoral artery occlusion as a result of Angio-Seal closure device deployment. Angio-Seal is the most commonly used vascular closure device following percutaneous coronary and peripheral catheterizations worldwide. A rare complication of Angio-Seal deployment is an occlusion of the femoral artery leading to limb ischemia requiring revascularization. Given its unique ability to cut both atherosclerotic plaque and the Angio-Seal anchor with a collagen plug at operator-directed planes, TurboHawk/HawkOne atherectomy device can be a fast and effective approach to treat Angio-Seal-associated femoral artery occlusions. We studied 13 consecutive patients who developed Angio-Seal-associated femoral artery occlusions that occurred from 3 hours to several weeks after catheterization. These patients were successfully treated with TurboHawk/HawkOne directional atherectomy followed by balloon angioplasty with no complications. During a mean follow-up period of 20.4 ± 17.3 months, 12 patients remained claudication free with no evidence of obstructive arterial disease of the treated segment on imaging studies. One patient developed restenosis that was treated with repeat atherectomy and balloon angioplasty following which he was asymptomatic at follow-up. The use of directional atherectomy followed by balloon angioplasty is a quick, safe, and effective endovascular approach to treating Angio-Seal-associated femoral artery occlusions. It is associated with an excellent success rate, no complications, and good midterm outcomes.

  17. Directional atherectomy facilitates the interventional procedure and leads to a low rate of recurrent stenosis in left anterior descending and left circumflex artery ostium stenoses: subgroup analysis of the FLEXI‐CUT study

    PubMed Central

    Dahm, J B; Ruppert, J; Hartmann, S; Vogelgesang, D; Hummel, A; Felix, S B

    2006-01-01

    Objectives To examine by retrospective analysis of data from the FLEXI‐CUT monocentre registry whether atherectomy can effectively simplify complex stent implantation in ostial bifurcation lesions by reducing the procedure to stenting of the left anterior descending (LAD) or left circumflex (LCX) artery ostium alone. Patients and methods All patients who had been enrolled in the prospective FLEXI‐CUT study (directional atherectomy with adjunctive balloon angioplasty) were retrospectively analysed on the basis of significant LAD or LCX ostial stenosis (⩾ 70% stenosis) deriving from an undiseased left main stem. The primary combined end point was the rate of target lesion revascularisation (TLR) and binary restenosis; secondary end points were procedural success and major adverse cardiac events (MACE) at the six‐month follow up. Results Of 30 patients enrolled with significant LAD or LCX ostium stenosis, 29 were effectively treated with directional atherectomy (96.7% procedural success). All patients underwent single‐vessel stenting procedures of solely the LAD or LCX ostium. At follow up, binary stenosis was 25% (6 of 24), TLR (angiographic plus clinical) 10.3% (3 of 29) and total MACE 6.9% (2 of 29). Conclusions Directional atherectomy with single‐vessel stenting procedures facilitates the interventional treatment of LAD and LCX ostium stenosis, and leads to remarkably low TLR and binary stenosis at follow up. PMID:16449510

  18. Subanalysis of the CONFIRM Registries: Acute Procedural Outcomes in Claudicant and Critical Limb Ischemia Patients With Varying Levels of Calcification Treated for Peripheral Arterial Disease With Orbital Atherectomy.

    PubMed

    Adams, George L; Das, Tony; Lee, Michael S; Beasley, Robert; Mustapha, Jihad

    2015-11-01

    Patients with peripheral arterial disease (PAD) can be classified into groups based upon the severity of the disease using the Rutherford classification system. This analysis compares the procedural outcomes of PAD patients treated with orbital atherectomy stratified by Rutherford class (1-3 = intermittent claudication; 4-6 = critical limb ischemia [CLI]), and acute angiographic outcomes of these patients stratified by degree of lesion calcification. The CONFIRM registry series was analyzed and included 1697 patients with intermittent claudication (Rutherford class 1-3) and 1320 patients with CLI (Rutherford class 4-6) treated with orbital atherectomy. The composite rate of dissection, perforation, slow-flow, vessel closure, spasm, embolism, and thrombus formation was compared between claudicants and CLI patients with varying degrees of lesion calcification. Patients with CLI were older and had a higher prevalence of diabetes, coronary artery disease, and renal disease (P<.001). Claudicants with moderately/severely calcified lesions had a lower rate of dissection (both non-flow limiting and flow-limiting) than claudicants with mildly/minimally calcified lesions. CLI patients with mildly/minimally calcified lesions had higher rates of embolism and thrombus than CLI patients with moderately/severely calcified lesions. Plaque modification with orbital atherectomy resulted in similar low procedural complication rates in the CLI group compared with the claudicant group. These results suggest that orbital atherectomy is safe and effective for treating calcified lesions in high-risk patients with varying severity of PAD symptoms.

  19. Orbital atherectomy for treating de novo, severely calcified coronary lesions: 3-year results of the pivotal ORBIT II trial.

    PubMed

    Lee, Michael; Généreux, Philippe; Shlofmitz, Richard; Phillipson, Daniel; Anose, Bynthia M; Martinsen, Brad J; Himmelstein, Stevan I; Chambers, Jeff W

    2017-06-01

    The presence of heavy coronary artery calcification increases the complexity of percutaneous coronary intervention (PCI) and increases the incidence of major adverse cardiac events (MACE): death, myocardial infarction (MI), target vessel revascularization (TVR), and stent thrombosis. The ORBIT II (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) trial reported low rates of procedural, 30-day, 1-year, and 2-year ischemic complications after treatment of de novo, severely calcified lesions with the Diamondback 360° Coronary Orbital Atherectomy System (OAS) (Cardiovascular Systems, Inc.). ORBIT II was a single-arm trial that enrolled 443 patients at 49U.S. sites; in this study, de novo, severely calcified coronary lesions were treated with OAS prior to stenting. The primary safety endpoint was 30-day MACE: the composite of cardiac death, MI, and TVR (inclusive of target lesion revascularization (TLR)). The primary efficacy endpoint was procedural success: stent delivery with a residual stenosis of <50% without the occurrence of in-hospital MACE.The present analysis reports the final, 3-year follow-up results from ORBIT II. The majority of subjects (88.2%) underwent PCI with drug-eluting stents after orbital atherectomy. There were 360 (81.3%) subjects who completed the protocol-mandated 3-year visit.The overall cumulative rate of 3-year MACE was 23.5%, including cardiac death (6.7%), MI (11.2%), and TVR (10.2%). The 3-year target lesion revascularization rate was 7.8%. In the final 3-year analysis of the ORBIT II trial, orbital atherectomy of severely calcified coronary lesions followed by stenting resulted in a low rate of adverse ischemic events compared with historical controls.Orbital atherectomy represents a safe and effective revascularization strategy for patients with severely calcified coronary lesions. The ORBIT II trial enrolled 443 subjects to study orbital atherectomy followed by stenting for de novo severely calcified coronary lesions. The overall cumulative 3-year MACE rate was 23.5%, including cardiac death (6.7%), MI (11.2%), and TVR (10.2%); the 3-year target lesion revascularization rate was 7.8%. Orbital atherectomy of heavily calcified coronary lesions followed by stenting results in a low rate of adverse ischemic events compared with historical controls; it represents a reasonable revascularization strategy for patients with severely calcified coronary lesions. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Percutaneous common femoral artery interventions using angioplasty, atherectomy, and stenting.

    PubMed

    Mehta, Manish; Zhou, Yi; Paty, Philip S K; Teymouri, Medhi; Jafree, Kamran; Bakhtawar, Humayun; Hnath, Jeffrey; Feustel, Paul

    2016-08-01

    This study evaluated the feasibility, safety, and effectiveness of endovascular interventions for common femoral artery (CFA) occlusive disease. Using a prospectively maintained multicenter database, we analyzed outcomes in 167 consecutive patients who underwent percutaneous CFA interventions for Rutherford class 3 to class 6 (R3-R6) disease. The standardized treatment approach included primary percutaneous transluminal angioplasty (PTA) only, atherectomy + PTA, and provisional stenting. Outcomes included technical failure rate, recurrence, complications, and major or minor amputation rate. Data were analyzed using multivariate regression analysis. During a 7-year period, 167 patients with R3 (n = 91 [54.5%]) and R4 to R6 (n = 76 [45.5%]) disease underwent CFA interventions that included PTA only (n = 114 [68.2%]), atherectomy ± PTA (n = 38 [22.8%]), and provisional stenting (n = 15 [9.0%]) for failed atherectomy ± PTA. Procedure-related complications included pseudoaneurysm (n = 1 [0.6%]), thrombosis (n = 1 [0.6%]), distal embolization (n = 1 [0.6%]), and death (R6, n = 1 [0.06%]). CFA restenosis was observed in 34 (20.4%) patents; these underwent further percutaneous (n = 18 [10.8%]) or surgical (n = 17 [10.2%]) revascularization that included CFA endarterectomy ± femoral distal bypass. Major or minor amputations were observed in none of the R3 patients and in only three (3.9%) and five (6.5%) of the R4 to R6 patients, respectively. Compared with the atherectomy + PTA group, patients in the PTA-only group had a significantly lower patency. Furthermore, during long-term mean follow-up of 42.5 months, the CFA provisional stent group had a 100% primary patency, which was significantly better than the primary patency in the CFA nonstent groups combined (77.0%; P = .0424). Data from this study to date would suggest that percutaneous CFA interventions in select patients are relatively safe and effective. In the long term, CFA stenting has significantly better primary patency than CFA atherectomy and PTA combined. CFA atherectomy + PTA has significantly better primary patency than CFA PTA-only at midterm, especially in patients with claudication. Future randomized controlled trials are warranted. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  1. Adjunctive Strategies in the Management of Resistant, ‘Undilatable’ Coronary Lesions After Successfully Crossing a CTO with a Guidewire

    PubMed Central

    Fairley, Sara L.; Spratt, James C.; Rana, Omar; Talwar, Suneel; Hanratty, Colm; Walsh, Simon

    2014-01-01

    Successful revascularisation of chronic total occlusions (CTOs) remains one of the greatest challenges in the era of contemporary percutaneous coronary intervention (PCI). Such lesions are encountered with increasing frequency in current clinical practice. A predictable increase in the future burden of CTO management can be anticipated given the ageing population, increased rates of renal failure, graft failure and diabetes mellitus. Given recent advances and developments in CTO PCI management, successful recanalisation can be anticipated in the majority of procedures undertaken at high-volume centres when performed by expert operators. Despite advances in device technology, the management of resistant, calcific lesions remains one of the greatest challenges in successful CTO intervention. Established techniques to modify calcific lesions include the use of high-pressure non-compliant balloon dilation, cutting-balloons, anchor balloons and high speed rotational atherectomy (HSRA). Novel approaches have proven to be safe and technically feasible where standard approaches have failed. A step-wise progression of strategies is demonstrated, from well-recognised techniques to techniques that should only be considered when standard manoeuvres have proven unsuccessful. These methods will be described in the setting of clinical examples and include use of very high-pressure non-compliant balloon dilation, intentional balloon rupture with vessel dissection or balloon assisted micro-dissection (BAM), excimer coronary laser atherectomy (ECLA) and use of HSRA in various ‘offlabel’ settings. PMID:24694106

  2. Critical hand ischemia treatment via orbital atherectomy-A single center observational retrospective analysis.

    PubMed

    Bahro, Abdul; Igyarto, Zsuzsanna; Martinsen, Brad

    2017-03-01

    Critical hand ischemia (CHI) can be devastating and may result in amputation. Distal vessel calcification has been shown to be a major factor in causing CHI. Atherectomy in the upper extremities is not typically considered due to the small anatomy; however, the Diamondback 360° Peripheral Orbital Atherectomy System (OAS) (Cardiovascular Systems, Inc.) can access treatment areas with a reference vessel diameter of 1.5mm. A retrospective, observational, single center (Merit Health Center, Jackson, MS) analysis of 11 CHI patients with calcific disease of the radial artery treated with orbital atherectomy (OAS) was completed. Demographics and procedural to 30-day outcomes were assessed. All patients had good blood flow to the hand after intervention and none experienced complications during or immediately post-procedure. At 30-days the freedom from revascularization and amputation was 100%, and all the wounds were healed. The following important principles were followed during the use of OAS for CHI: (1) ACT was therapeutic (~250s); (2) Gentle wire manipulation; (3) Utilization of a small OAS crown (1.25mm); (4) Aggressive vasodilator use-given through the exchange catheter; (5) Angioplasty balloon was matched to the size of the vessel and long and low pressure inflations were completed. Critical hand ischemia can be treated with endovascular techniques. Obtaining good outflow to the fingers is critical for wound healing and preventing amputation. Orbital atherectomy is a useful tool in preparing vessels for balloon angioplasty; particularly in cases where calcification is present. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Histopathological Evidence of Adventitial or Medial Injury Is a Strong Predictor of Restenosis During Directional Atherectomy for Peripheral Artery Disease.

    PubMed

    Tarricone, Arthur; Ali, Ziad; Rajamanickam, Anitha; Gujja, Karthik; Kapur, Vishal; Purushothaman, K-Raman; Purushothaman, Meerarani; Vasquez, Miguel; Zalewski, Adrian; Parides, Micheal; Overbey, Jessica; Wiley, Jose; Krishnan, Prakash

    2015-10-01

    To investigate the impact on restenosis rates of deep injury to the adventitial layer during directional atherectomy. Between 2007 and 2010, 116 consecutive patients (mean age 69.6 years; 56 men) with symptomatic femoropopliteal stenoses were treated with directional atherectomy at a single center. All patients had claudication and TASC A/B lesions in the superficial femoral or popliteal arteries. Histopathology analysis of atherectomy specimens was performed to identify adventitial injury. Clinical follow-up included physical examination and duplex ultrasound scans at 3, 6, and 12 months in all patients. The primary endpoint was the duplex-documented 1-year rate of restenosis, which was determined by a peak systolic velocity ratio <2.4. Patients were dichotomized by the presence or absence of adventitial or medial cuts as evaluated by histopathology. Adventitial injury were identified in 62 (53%) of patients. There were no differences in baseline demographic and clinical features (p>0.05), lesion length (58.7±12.8 vs 56.2±13.6 mm, p=0.40), or vessel runoff (1.9±0.6 vs 2.0±0.6, p=0.37) between patients with and without adventitial injury, respectively. The overall 1-year incidence of restenosis was 57%, but the rate was significantly higher (p<0.0001) in patients with adventitial or medial injury (97%, 60/62) as compared with those without (11%, 6/54). Lack of adventitial injury after atherectomy for femoropopliteal stenosis is strongly related to patency at 1 year. © The Author(s) 2015.

  4. Drug-coated balloon angioplasty after directional atherectomy improves outcome in restenotic femoropopliteal arteries.

    PubMed

    Sixt, Sebastian; Carpio Cancino, Oscar Gerardo; Treszl, András; Beschorner, Ulrich; Macharzina, Roland; Rastan, Aljoscha; Krankenberg, Hans; Neumann, Franz-Josef; Zeller, Thomas

    2013-09-01

    Restenosis remains an unresolved problem despite different treatment modalities and new stent technology in femoropopliteal arteries. No standard therapy has proven to provide acceptable outcome data for this entity. Directional atherectomy alone did not result in satisfactory long-term patency rates. The outcome might be improved in conjunction with drug-coated balloon angioplasty. In this retrospective study, restenotic lesions of the femoropopliteal arteries were treated with directed atherectomy in 89 lesions of consecutive patients (58% male; mean age, 69 ± 11 years). All patients received adjunctive treatment with conventional balloon percutaneous angioplasty (PTA; n = 60) or drug-coated balloon angioplasty (DCB; n = 29). Lesion location was in the stent (DCB [n = 27] vs PTA [n = 36]) and in native restenotic vessels (DCB [n = 2] vs PTA [n = 25]). The 1-year Kaplan-Meier freedom from restenosis estimates (95% confidence intervals) in the DCB and PTA groups were 84.7% (70.9%-98.5%) and 43.8% (30.5%-57.1%), respectively. In a multivariable Cox model for restenosis, DCB treatment had a hazard ratio (95% confidence interval) of 0.28 (0.12-0.66; P = .0036) compared with the PTA group. In the multivariable model for procedural success, the effect of treatment did not differ between PTA and DCB (P = .134). The combination of directed atherectomy with adjunctive DCB is associated with a better event-free survival at 12 months of follow-up compared with PTA after directed atherectomy. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  5. Orbital atherectomy as an adjunct to debulk difficult calcified lesions prior to mesenteric artery stenting.

    PubMed

    Manunga, Jesse M; Oderich, Gustavo S

    2012-08-01

    To describe a technique in which percutaneous orbital atherectomy is used to debulk heavily calcified superior mesenteric artery (SMA) occlusions as an adjunct in patients undergoing angioplasty and stenting. The technique is demonstrated in a 62-year-old woman with a replaced right hepatic artery originating from an SMA occluded by densely calcified lesions. Via a left transbrachial approach, a 7-F MPA guide catheter was used to engage the ostium of the SMA, which was crossed using a catheter and guidewire. The calcified lesion was debulked using the 2-mm Diamondback 360° orbital atherectomy system. The wire was exchanged for a 0.014-inch filter wire and 0.018-inch guidewire. Using a 2-guidewire technique, the SMA was stented with a self-expanding stent for the distal lesion that crossed side branches and a balloon-expandable stent at the ostium. A 0.014-inch guidewire was placed into the replaced hepatic artery through a cell of the self-expanding stent, followed by deployment of a small balloon-expandable stent to address the residual lesion. The use of orbital atherectomy to debulk occluded and heavily calcified SMA lesions may optimize the technical results with angioplasty and stenting.

  6. Directional atherectomy of a heavy calcified axillary artery stenosis inducing critical hand ischemia.

    PubMed

    Anzuini, Angelo; Palloshi, Altin; Aprigliano, Gianfranco; Ielasi, Alfonso

    2013-07-01

    The presence of a severe calcified peripheral artery lesion is responsible for a poor response to balloon dilation, due to significant acute vessel recoil and frequent flow-limiting dissections requiring stent implantation. This possibility could be associated with very high compression and/or fracture rates particularly in cases of lesion located at the mobile joints. In this setting directional atherectomy offers the theoretical advantages of eliminating stretch injury on arterial walls and reducing the restenosis rate by direct plaque excision. In this report, we present a case of critical hand ischemia due to a heavily calcified axillary artery lesion managed by directional atherectomy and balloon angioplasty followed by immediate angiographic success and sustained clinical benefit up to 3 years of follow-up.

  7. Temporal changes in radial access use, associates and outcomes in patients undergoing PCI using rotational atherectomy between 2007 and 2014: results from the British Cardiovascular Intervention Society national database.

    PubMed

    Kinnaird, Tim; Cockburn, James; Gallagher, Sean; Choudhury, Anirban; Sirker, Alex; Ludman, Peter; de Belder, Mark; Copt, Samuel; Mamas, Mamas; de Belder, Adam

    2018-04-01

    Access site choice for cases requiring rotational atherectomy (PCI-ROTA) is poorly defined. Using the British Cardiovascular Intervention Society PCI database, temporal changes and contemporary associates/outcomes of access site choice for PCI-ROTA were studied. Data were analysed from 11,444 PCI-ROTA procedures performed in England and Wales between 2007 and 2014. Multivariate logistic regression was used to identify predictors of access site choice and its association with outcomes. For PCI-ROTA, radial access increased from 19.6% in 2007 to 58.6% in 2014. Adoption of radial access was slower in females, those with prior CABG, and in patients with chronic occlusive (CTO) or left main disease. In 2013/14, the strongest predictors of femoral artery use were age (OR 1.02, [1.005-1.036], P = .008), CTO intervention (OR 1.95, [1.209-3.314], P = .006), and history of previous CABG (OR 1.68, [1.124-2.515], P = .010). Radial access was associated with reductions in overall length of stay, and increased rates of same-day discharge. Procedural success rates were similar although femoral access use was associated with increased access site complications (2.4 vs. 0.1%, P < .001). After adjustment for baseline differences, arterial complications (OR 15.6, P < .001), transfusion (OR 12.5, P = .023) and major bleeding OR 6.0, P < .001) remained more common with FA use. Adjusted mortality and MACE rates were similar in both groups. In contemporary practice, radial access for PCI-ROTA results in similar procedural success when compared to femoral access but is associated with shorter length of stay, and lower rates of vascular complication, major bleeding and transfusion. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. An Algorithm for the Use of Embolic Protection During Atherectomy for Femoral Popliteal Lesions.

    PubMed

    Krishnan, Prakash; Tarricone, Arthur; Purushothaman, K Raman; Purushothaman, Meerarani; Vasquez, Miguel; Kovacic, Jason; Baber, Usman; Kapur, Vishal; Gujja, Karthik; Kini, Annapoorna; Sharma, Samin

    2017-02-27

    This study sought to identify an algorithm for the use of distal embolic protection on the basis of angiographic lesion morphology and vascular anatomy for patients undergoing atherectomy for femoropopliteal lesions. Atherectomy has been shown to create more embolic debris than angioplasty alone. Distal embolic protection has been shown to be efficacious in capturing macroemboli; however, no consensus exists for the appropriate lesions to use distal embolic protection during atherectomy. Patients with symptomatic lower extremity peripheral artery disease treated with atherectomy and distal embolic protection were evaluated to identify potential predictors of DE. Plaque collected from the SilverHawk nose cone subset was sent to pathology for analysis to evaluate the accuracy of angiography in assessing plaque morphology. Significant differences were found in lesion length (142.1 ± 62.98 vs. 56.91 ± 41.04; p = 0.0001), low-density lipoprotein (82.3 ± 40.3 vs. 70.9 ± 23.2; p = 0.0006), vessel runoff (1.18 ± 0.9 vs. 1.8 ± 0.9; p = 0.0001), chronic total occlusion (131 vs. 10; p = 0.001), in-stent restenosis (33 vs. 6; p = 0.0081), and calcified lesions (136 vs. 65; p < 0.001). In simple logistic regression analysis lesion length, reference vessel diameter, chronic total occlusion, runoff vessels, and in-stent restenosis were found to be strongly associated with macroemboli. Angiographic assessment of plaque morphology was accurate. Positive predictive value of 92.31, negative predictive value of 95.35, sensitivity of 92.31, and specificity of 95.35 for calcium; positive predictive value of 95.56, negative predictive value of 100, sensitivity of 100, and specificity of 92.31 for atherosclerotic plaque. Thrombus/in-stent restenosis was correctly predicted. Chronic total occlusion, in-stent restenosis, thrombotic, calcific lesions >40 mm, and atherosclerotic lesions >140 mm identified by peripheral angiography necessitate concomitant filter use during atherectomy to prevent embolic complications. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  9. Intravascular ultrasound evaluation of JETSTREAM atherectomy removal of superficial calcium in peripheral arteries.

    PubMed

    Maehara, Akiko; Mintz, Gary S; Shimshak, Thomas M; Ricotta, Joseph J; Ramaiah, Venkatesh; Foster, Malcolm T; Davis, Thomas P; Gray, William A

    2015-05-01

    Endovascular treatment of calcified femoral-popliteal disease is challenging. We sought to evaluate the mechanism of lumen gain when using the JETSTREAM Atherectomy System to treat calcified peripheral artery lesions. The JETSTREAM Calcium Study was a prospective, single-arm, multicentre study to evaluate the JETSTREAM Atherectomy System for severely calcified femoral-popliteal artery lesions, i.e., patients with claudication and lesions with superficial calcium >90° and >5 mm in length as determined by intravascular ultrasound (IVUS). The 2.1 mm catheter was used in this study without distal protection. Fifty-five patients underwent angiographic screening: 26 (45%) met IVUS inclusion criteria. Angiographic calcium was moderate in eight cases and severe in 14, with no available data for four cases. Visual diameter stenosis was 86±9% pre-treatment, 37±13% post atherectomy, and 10±6% post adjunctive treatment (adjunctive PTA+stenting in eight and adjunct PTA alone in 16). IVUS showed lumen area increased from 6.6±3.7 mm2 to 10.0±3.6 mm2 (p=0.001): calcium reduction was responsible for 86±23% of the lumen increase. Although the superficial calcium arc did not change (151±70° to 146±71°, p=0.83), the arc of reverberation increased (23±20° to 65±40°, p=0.006), indicating device-related modification of calcium. Adjunctive balloon angioplasty was performed in 62% of the lesions, and stent implantation in 31%. In 11 cases with adjunctive balloon dilation, the MLA increased from 7.1 (6.4, 7.8) mm2 post atherectomy to 11.9 (10.3, 13.5) mm2 post balloon (p<0.001) without flow-limiting dissection. No major adverse events occurred up to 30 days post procedure in either the study group or the patients who were excluded from the analysis. The JETSTREAM Atherectomy System increased lumen dimensions in moderately or severely calcified femoral-popliteal lesions by removing superficial calcium without major complications.

  10. Effective endovascular treatment of calcified femoropopliteal disease with directional atherectomy and distal embolic protection: final results of the DEFINITIVE Ca⁺⁺ trial.

    PubMed

    Roberts, David; Niazi, Khusrow; Miller, William; Krishnan, Prakash; Gammon, Roger; Schreiber, Theodore; Shammas, Nicolas W; Clair, Daniel

    2014-08-01

    The purpose of the DEFINITIVE Ca(++) study was to evaluate the safety and effectiveness of directional atherectomy and distal embolic protection, used together to treat moderate to severely calcified femoropopliteal lesions. Despite advances in endovascular treatment modalities, treatment of calcified lesions remains a challenge. A total of 133 subjects with 168 moderate to severely calcified lesions were enrolled. Lesions were treated with directional atherectomy devices, coupled with distal embolic protection. The 30-day freedom from MAE rate was 93.1%. Per angiographic core laboratory assessment, the primary effectiveness endpoint (≤50% residual diameter stenosis) was achieved in 92.0% (lower confidence bound of 87.6%) of lesions. By core lab analysis, these results did not achieve the success criteria (90%) for the primary effectiveness objective. Per site assessment, the objective was met with the endpoint being achieved in 97.0% (lower confidence bound 93.8%). A mean residual diameter stenosis of 33.3% was achieved with the directional atherectomy device. This was further decreased to 24.1% with the use of adjunctive therapy. The proportion of asymptomatic subjects [Rutherford Clinical Category (RCC) = 0] increased from 0% at baseline to 52.3% at the 30-day follow-up visit. In total, 88.5% of subjects experienced an improvement of one or more Rutherford categories. The results of the DEFINITIVE Ca++ study demonstrate that the SilverHawk and TurboHawk atherectomy devices are safe and effective in the endovascular treatment of moderate to severely calcified lesions in the superficial femoral and/or popliteal arteries when used with the SpiderFX distal embolic protection device. © 2014 The Authors. Catheterization and Cardiovascular Interventions. Published by Wiley Periodicals, Inc.

  11. Pooled analysis of the CONFIRM registries: impact of gender on procedure and angiographic outcomes in patients undergoing orbital atherectomy for peripheral artery disease.

    PubMed

    Lee, Michael S; Canan, Timothy; Rha, Seung-Woon; Mustapha, Jihad; Adams, George L

    2015-02-01

    To compare the acute procedure and angiographic outcomes of peripheral artery disease (PAD) patients treated with orbital atherectomy stratified by gender. The CONFIRM I, II, and III registries are US multicenter, nonrandomized, all-comers registries of PAD patients who were treated with orbital atherectomy. All patients with gender specified in the registry database were included in the current analysis, which compared the final residual stenosis achieved after atherectomy and the rate of acute complications in female and male patients. The 3 registries included 3131 patients with 4761 lesions: 1261 women (mean age 73.2 ± 10.7 years) with 1874 lesions and 1870 men (mean age 70.4 ± 10.2) with 2887 lesions. The women were older (p < 0.001) and had a higher but nonsignificant prevalence of critical limb ischemia (p = 0.075). After treatment, the final residual stenosis in women vs. men was 9% ± 11% vs. 11% ± 11%, respectively (p < 0.001). Women had a higher rate of all types of dissection (13.3% vs. 9.9%, p<0.001). However, both genders had similar rates of flow-limiting dissections (1.6% vs. 1.4%, p = 0.61), perforation, slow flow, vessel closure, spasm, embolism, and thrombus formation. The gender analysis of the CONFIRM registries revealed that there was successful lesion modification with orbital atherectomy in both men and women; however, women had a higher rate of dissection (all types). This difference is likely because of the older age and higher percentage of critical limb ischemia in women in this cohort. These results, however, suggest that additional studies should be completed to further understand the increased risks for women vs. men during endovascular procedures. © The Author(s) 2015.

  12. Expression of tumour necrosis factor alpha and accumulation of fibronectin in coronary artery restenotic lesions retrieved by atherectomy.

    PubMed Central

    Clausell, N.; de Lima, V. C.; Molossi, S.; Liu, P.; Turley, E.; Gotlieb, A. I.; Adelman, A. G.; Rabinovitch, M.

    1995-01-01

    BACKGROUND--The formation of coronary artery neointima experimentally induced in piglets after cardiac transplantation is related to an immune-inflammatory reaction associated with increased expression of T cells and inflammatory mediators (tumour necrosis factor alpha and interleukin 1 beta) and upregulation of fibronectin. In vivo blockade of tumour necrosis factor alpha in rabbits after cardiac transplantation results in reduced neointimal formation. The objective of this study was to investigate the hypothesis that coronary restenosis after atherectomy or percutaneous balloon angioplasty is associated with a similar inflammatory cascade initiated by mechanical injury. METHODS--Specimens taken at coronary atherectomy were analysed from 16 patients. Nine had had the procedure performed twice, firstly, to remove a primary lesion, and secondly, to remove a restenotic lesion. Seven had percutaneous balloon angioplasty after removal of restenotic tissue. Coronary atherectomy specimens were analysed by immunohistochemistry for the presence of T cells, macrophages, major histocompatibility complex II, interleukin 1 beta, tumour necrosis factor alpha, fibronectin, and the receptor for hyaluronan mediated motility. RESULTS--The groups were clinically and angiographically similar with equivalent lumens before and after atherectomy. Restenotic lesions had increased expression of tumour necrosis factor alpha and fibronectin compared with the primary lesions (P < 0.05 for both). There was also a trend towards a greater number of T cells and increased expression of interleukin 1 beta. CONCLUSIONS--Restenosis is associated with increased expression of tumour necrosis factor alpha and fibronectin, suggesting that an immune-inflammatory reaction probably contributes to neointimal formation and may represent a form of wound healing and repair secondary to mechanical injury. Images PMID:7626352

  13. Preintervention lesion remodelling affects operative mechanisms of balloon optimised directional coronary atherectomy procedures: a volumetric study with three dimensional intravascular ultrasound

    PubMed Central

    von Birgelen, C; Mintz, G; de Vrey, E A; Serruys, P; Kimura, T; Nobuyoshi, M; Popma, J; Leon, M; Erbel, R; de Feyter, P J

    2000-01-01

    AIMS—To classify atherosclerotic coronary lesions on the basis of adequate or inadequate compensatory vascular enlargement, and to examine changes in lumen, plaque, and vessel volumes during balloon optimised directional coronary atherectomy procedures in relation to the state of adaptive remodelling before the intervention.
DESIGN—29 lesion segments in 29 patients were examined with intravascular ultrasound before and after successful balloon optimised directional coronary atherectomy procedures, and a validated volumetric intravascular ultrasound analysis was performed off-line to assess the atherosclerotic lesion remodelling and changes in plaque and vessel volumes that occurred during the intervention. Based on the intravascular ultrasound data, lesions were classified according to whether there was inadequate (group I) or adequate (group II) compensatory enlargement.
RESULTS—There was no significant difference in patient and lesion characteristics between groups I and II (n = 10 and 19), including lesion length and details of the intervention. Quantitative coronary angiographic data were similar for both groups. However, plaque and vessel volumes were significantly smaller in group I than in II. In group I, 9 (4)% (mean (SD)) of the plaque volume was ablated, while in group II 16 (11)% was ablated (p = 0.01). This difference was reflected in a lower lumen volume gain in group I than in group II (46 (18) mm3 v 80 (49) mm3 (p < 0.02)).
CONCLUSIONS—Preintervention lesion remodelling has an impact on the operative mechanisms of balloon optimised directional coronary atherectomy procedures. Plaque ablation was found to be particularly low in lesions with inadequate compensatory vascular enlargement.


Keywords: intravascular ultrasound; ultrasonics; remodelling; coronary artery disease; atherectomy PMID:10648496

  14. Impact of Advanced Age on Procedural and Acute Angiographic Outcomes in Patients Treated for Peripheral Artery Disease With Orbital Atherectomy: A CONFIRM Registries Subanalysis.

    PubMed

    Lee, Michael S; Beasley, Robert; Adams, George L

    2015-08-01

    Data on the outcomes of elderly patients with peripheral arterial disease (PAD) who undergo orbital atherectomy are limited. This analysis compares the procedural and acute angiographic outcomes of PAD patients treated with orbital atherectomy stratified by age (≥ 75 years of age [elderly] vs <75 years of age [younger]). The CONFIRM registry series with non-missing age was analyzed and included 2995 real-world PAD patients (4557 lesions) with 1753 younger patients (2637 lesions) and 1242 elderly patients (1920 lesions) treated with orbital atherectomy. The composite rate of adverse events including dissection, perforation, slow flow, vessel closure, spasm, embolism, and thrombus formation was compared between groups. Elderly patients had a higher proportion of females (47.5% vs 35.3%; P<.001), more patients with critical limb ischemia (49.9% vs 39.3%; P<.001), longer lesion length (75.0 ± 74.1 mm vs 69.9 ± 68.9 mm; P=.01), and more lesions treated below the knee (38.9% vs 34.4%; P=.01). Younger and elderly patients had similar rates of composite adverse events (22.0% vs 21.3%; P=.81), dissection (11.4% vs 10.5%; P=.72), vessel closure (1.7% vs 1.1%; P=.13), spasm (6.3% vs 6.4%; P=.96), and embolism (2.5% vs 1.6%; P=.31). Elderly patients had a lower rate of thrombus formation (0.9% vs 1.6%; P=.03), but a higher perforation rate (1.2% vs 0.4%; P=.01). Orbital atherectomy resulted in similar composite rates of adverse events despite the elderly having unfavorable baseline Rutherford classification and lesion characteristics. The higher rate of perforation may be explained by longer and more below-the-knee lesions.

  15. Effective Endovascular Treatment of Calcified Femoropopliteal Disease With Directional Atherectomy and Distal Embolic Protection: Final Results of the DEFINITIVE Ca++ Trial

    PubMed Central

    Roberts, David; Niazi, Khusrow; Miller, William; Krishnan, Prakash; Gammon, Roger; Schreiber, Theodore; Shammas, Nicolas W; Clair, Daniel

    2014-01-01

    Objectives The purpose of the DEFINITIVE Ca++ study was to evaluate the safety and effectiveness of directional atherectomy and distal embolic protection, used together to treat moderate to severely calcified femoropopliteal lesions. Background Despite advances in endovascular treatment modalities, treatment of calcified lesions remains a challenge. Methods A total of 133 subjects with 168 moderate to severely calcified lesions were enrolled. Lesions were treated with directional atherectomy devices, coupled with distal embolic protection. Results The 30-day freedom from MAE rate was 93.1%. Per angiographic core laboratory assessment, the primary effectiveness endpoint (≤50% residual diameter stenosis) was achieved in 92.0% (lower confidence bound of 87.6%) of lesions. By core lab analysis, these results did not achieve the success criteria (90%) for the primary effectiveness objective. Per site assessment, the objective was met with the endpoint being achieved in 97.0% (lower confidence bound 93.8%). A mean residual diameter stenosis of 33.3% was achieved with the directional atherectomy device. This was further decreased to 24.1% with the use of adjunctive therapy. The proportion of asymptomatic subjects [Rutherford Clinical Category (RCC) = 0] increased from 0% at baseline to 52.3% at the 30-day follow-up visit. In total, 88.5% of subjects experienced an improvement of one or more Rutherford categories. Conclusions The results of the DEFINITIVE Ca++ study demonstrate that the SilverHawk™ and TurboHawk™ atherectomy devices are safe and effective in the endovascular treatment of moderate to severely calcified lesions in the superficial femoral and/or popliteal arteries when used with the SpiderFX™ distal embolic protection device. © 2014 Wiley Periodicals, Inc. PMID:24402764

  16. A Comparison of Clinical Outcomes for Diabetic and Nondiabetic Patients Following Directional Atherectomy in the DEFINITIVE LE Claudicant Cohort.

    PubMed

    Garcia, Lawrence A; Jaff, Michael R; Rocha-Singh, Krishna J; Zeller, Thomas; Bosarge, Christopher; Kamat, Suraj; McKinsey, James F

    2015-10-01

    To report a subset analysis that evaluated the hypothesis that directional atherectomy for peripheral artery disease in diabetic claudicants has noninferior primary patency at 12 months compared with nondiabetic claudicants. DEFINITIVE LE, a US/European multicenter study, assessed the effectiveness of directional atherectomy using SilverHawk/TurboHawk systems for treatment of peripheral artery disease in the superficial femoral, popliteal, and infrapopliteal arteries. Of the 800 patients enrolled in the study, only the 598 claudicant patients (mean age 69.5±10.4 years; 336 men) who were classified at baseline as Rutherford category 1-3 were eligible for this subset analysis. Of these, 46.8% (280/598) had diabetes. Follow-up to 12 months included duplex ultrasound examination, functional assessments, and adverse event evaluations. Independent angiographic and duplex ultrasound core laboratories assessed primary patency and secondary endpoints; a clinical events committee adjudicated adverse events. Although diabetics had significantly more baseline comorbidities, 12-month primary patency (77.0%) was no different than for nondiabetics (77.9%; superiority p=0.98; noninferiority p<0.001) across all anatomic territories treated. Freedom from clinically driven target lesion revascularization was no different between diabetics (83.8%) and nondiabetics (87.5%) overall (p=0.19) or by lesion locations. Secondary clinical outcomes (Rutherford category, ankle-brachial index, and walking impairment) improved at 12 months for both diabetics and nondiabetics. Noninferior 12-month patency rates demonstrate that directional atherectomy is an effective treatment in diabetic as well as nondiabetic claudicants. Directional atherectomy remains an attractive treatment option, improving luminal diameters without stents, which preserves future treatment options for both diabetic and nondiabetic patients with progressive, diffuse vascular disease. © The Author(s) 2015.

  17. Mechanical Recanalization of Subacute Vessel Occlusion in Peripheral Arterial Disease with a Directional Atherectomy Catheter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Massmann, Alexander, E-mail: Alexander.Massmann@uks.eu; Katoh, Marcus; Shayesteh-Kheslat, Roushanak

    2012-10-15

    Purpose: To retrospectively examine the technical feasibility and safety of directional atherectomy for treatment of subacute infrainguinal arterial vessel occlusions. Methods: Five patients (one woman, four men, age range 51-81 years) with peripheral arterial disease who experienced sudden worsening of their peripheral arterial disease-related symptoms during the last 2-6 weeks underwent digital subtraction angiography, which revealed vessel occlusion in native popliteal artery (n = 4) and in-stent occlusion of the superficial femoral artery (n = 1). Subsequently, all patients were treated by atherectomy with the SilverHawk (ev3 Endovascular, USA) device. Results: The mean diameter of treated vessels was 5.1 {+-}more » 1.0 mm. The length of the occlusion ranged 2-14 cm. The primary technical success rate was 100%. One patient experienced a reocclusion during hospitalization due to heparin-induced thrombocytopenia. There were no further periprocedural complications, in particular no peripheral embolizations, until hospital discharge or during the follow-up period of 1 year. Conclusion: The recanalization of infrainguinal arterial vessel occlusions by atherectomy with the SilverHawk device is technically feasible and safe. In our limited retrospective study, it was associated with a high technical success rate and a low procedure-related complication rate.« less

  18. Focusing optical waves with a rotationally symmetric sharp-edge aperture

    NASA Astrophysics Data System (ADS)

    Hu, Yanwen; Fu, Shenhe; Li, Zhen; Yin, Hao; Zhou, Jianying; Chen, Zhenqiang

    2018-04-01

    While there has been various kinds of patterned structures proposed for wave focusing, these patterned structures usually involve complicated lithographic techniques since the element size of the patterned structures should be precisely controlled in microscale or even nanoscale. Here we propose a new and straightforward method for focusing an optical plane wave in free space with a rotationally symmetric sharp-edge aperture. The focusing phenomenon of wave is realized by superposition of a portion of the higher-order symmetric plane waves generated from the sharp edges of the apertures, in contrast to previously focusing techniques which usually depend on a curved phase. We demonstrate both experimentally and theoretically the focusing effect with a series of apertures having different rotational symmetry, and find that the intensity of the hotspots could be controlled by the symmetric strength of the sharp-edge apertures. The presented results would advance the conventional wisdom that light would diffract in all directions and become expanding when it propagates through an aperture. The proposed method is easy to be processed, and might open potential applications in interferometry, image, and superresolution.

  19. Safety and effectiveness of the Phoenix Atherectomy System in lower extremity arteries: Early and midterm outcomes from the prospective multicenter EASE study.

    PubMed

    Davis, Thomas; Ramaiah, Venkatesh; Niazi, Khusrow; Martin Gissler, Hans; Crabtree, Tami

    2017-12-01

    Objectives To evaluate the novel Phoenix Atherectomy System as percutaneous treatment of de novo and restenotic infrainguinal arterial lesions. Methods This prospective, multicenter, nonrandomized investigational device exemption trial was conducted across 16 US and German centers between August 2010 and April 2013. Intention-to-treat enrollment was 128 patients (mean age: 71.8 years, 59% male) with 149 lesions (mean length: 34 mm, mean diameter stenosis: 89.5%), and the primary analysis per-protocol population consisted of 105 patients with 123 lesions. The primary efficacy endpoint, technical success, was the achievement of acute debulking with a post-atherectomy residual diameter stenosis ≤50% (before adjunctive therapy). The primary safety endpoint was the major adverse event (MAE) rate through 30 days. Results For the primary analysis per-protocol population, the rate of lesion technical success was 95.1% (117/123), with the lower limit of the 95% CI 90.6%, meeting the prospectively established target performance goal of ≥86%. After post-atherectomy adjunctive therapy, residual stenosis was ≤30% for 99.2% (122/123) of lesions (mean final diameter stenosis 10.5%). Improvement of ≥1 Rutherford class occurred for 74.5% of patients through 30 days and for 80% through six months. MAEs were experienced by 5.7% (6/105) of patients through 30 days (with the upper limit of the 95% CI 11.0%, meeting the target performance goal of <20%), and 16.8% through six months. Six-month freedom from TLR and TVR was 88.0% and 86.1%, respectively. Conclusions Based on the high rate of technical success and the low rates of MAEs through six months, the Phoenix Atherectomy System is safe and effective for the debulking of lower-extremity arterial lesions. ClinicalTrials.gov identifier NCT01541774.

  20. Ultrasound detection of cavitation as a phenomenon common to intervention devices causing tissue ablation

    NASA Astrophysics Data System (ADS)

    Bach, David S.; Armstrong, William F.; Erbel, Raimund; Ellis, Stephen G.; Sousa, Joao; Rosenschein, Uri

    1992-08-01

    Cavitation previously has been observed in association with ultrasonic angioplasty and high- frequency rotational atherectomy. This study evaluates the production of cavitation accompanying the use of several catheter-based devices under development or in current use in the practice of interventional cardiology. Catheters were examined in an in vitro model, and cavitation was evaluated using standard ultrasound imaging equipment. Cavitation was detected with each of the devices that effects tissue ablation, but not tissue resection. Devices produced characteristic patterns of cavitation dependent on the mode of energy release of the device. The size, but not the intensity, of the cavitation effect was proportional to the energy output of the devices. The precise role of cavitation in the mechanism of tissue ablation remains uncertain.

  1. Three-year results after directional atherectomy of calcified stenotic lesions of the superficial femoral artery.

    PubMed

    Minko, P; Buecker, A; Jaeger, S; Katoh, M

    2014-10-01

    To investigate the 3-year outcome of patients with peripheral arterial disease (PAD) and heavily calcified stenotic lesions of the superficial femoral artery after directional atherectomy. Fifty-three patients (mean age 67 ± 10 years; 18 females, 35 males, TASC B and C, mean lesion length 7.9 ± 3.5 cm) with PAD (Rutherford 2-6) were enrolled into this prospective monocentric study. In total, 59 calcified lesions of the superficial femoral artery were treated with the Silverhawk atherectomy device (Covidien, Plymouth, MN, USA). Patients were followed-up for 36 months with a 6-month interval to perform clinical re-evaluation, including measurement of maximum walking distance and ankle-brachial index (ABI) as well as duplex-sonography. The primary success rate of the procedure was 92 %. In five cases (8 %), additional balloon-PTA and/or stent-PTA was necessary. Procedure-related embolization occurred in seven cases (12 %), which were all successfully treated by aspiration. The primary patency rate after 3 years was 55 %. Median Rutherford score decreased significantly from 5 to 0 after 36 months (p < 0.001). At the same time, the ABI increased from 0.65 to 1.12 (not significant). The limb-salvage rate after 3 years was 87 %. In this subgroup of patients with POD and calcified stenotic lesions, atherectomy was successfully applied to decrease the plaque burden. Results after 3 years showed a significant decrease of Rutherford score with persistent improvement of ABI and reasonable patency rate.

  2. One-Year Outcomes Following Directional Atherectomy of Popliteal Artery Lesions: Subgroup Analysis of the Prospective, Multicenter DEFINITIVE LE Trial

    PubMed Central

    Rastan, Aljoscha; McKinsey, James F.; Garcia, Lawrence A.; Rocha-Singh, Krishna J.; Jaff, Michael R.; Harlin, Stuart; Kamat, Suraj; Janzer, Sean; Zeller, Thomas

    2017-01-01

    Purpose: To report the effectiveness of directional atherectomy for the treatment of popliteal artery occlusive disease. Methods: This subset of the prospective, multicenter, single-arm DEFINITIVE LE trial included 158 patients (mean age 72.0±10.9 years; 82 men) who underwent directional atherectomy in 162 popliteal artery lesions between 2009 and 2011. Forty-eight (30.4%) patients were suffering from critical limb ischemia (CLI). The mean lesion length was 5.8±3.9 cm; 38 (23.5%) arteries were occluded. The primary outcome measure for patients with intermittent claudication (IC) was duplex ultrasound–defined primary patency at 1 year; the outcome for subjects with CLI was freedom from major amputation of the target limb at 1 year. Outcomes and adverse events were independently assessed. Results: Procedure success (≤30% residual stenosis) was achieved in 84.4% of treated lesions; adjunctive stenting was required in 6 (3.7%) of the 162 lesions. The 1-year primary patency rate was 75.0% (IC patients 78.2% and CLI patients 67.5%, p=0.118). The freedom from major amputation in both cohorts was 100%. In both IC and CLI patients, significant improvements were demonstrated at 1 year in the Rutherford category, walking distance, and quality of life in comparison to baseline. Conclusion: This study indicates that directional atherectomy in popliteal arteries leads to favorable technical and clinical results at 1 year for claudicant as well as CLI patients. PMID:29117818

  3. One-Year Outcomes Following Directional Atherectomy of Popliteal Artery Lesions: Subgroup Analysis of the Prospective, Multicenter DEFINITIVE LE Trial.

    PubMed

    Rastan, Aljoscha; McKinsey, James F; Garcia, Lawrence A; Rocha-Singh, Krishna J; Jaff, Michael R; Harlin, Stuart; Kamat, Suraj; Janzer, Sean; Zeller, Thomas

    2018-02-01

    To report the effectiveness of directional atherectomy for the treatment of popliteal artery occlusive disease. This subset of the prospective, multicenter, single-arm DEFINITIVE LE trial included 158 patients (mean age 72.0±10.9 years; 82 men) who underwent directional atherectomy in 162 popliteal artery lesions between 2009 and 2011. Forty-eight (30.4%) patients were suffering from critical limb ischemia (CLI). The mean lesion length was 5.8±3.9 cm; 38 (23.5%) arteries were occluded. The primary outcome measure for patients with intermittent claudication (IC) was duplex ultrasound-defined primary patency at 1 year; the outcome for subjects with CLI was freedom from major amputation of the target limb at 1 year. Outcomes and adverse events were independently assessed. Procedure success (≤30% residual stenosis) was achieved in 84.4% of treated lesions; adjunctive stenting was required in 6 (3.7%) of the 162 lesions. The 1-year primary patency rate was 75.0% (IC patients 78.2% and CLI patients 67.5%, p=0.118). The freedom from major amputation in both cohorts was 100%. In both IC and CLI patients, significant improvements were demonstrated at 1 year in the Rutherford category, walking distance, and quality of life in comparison to baseline. This study indicates that directional atherectomy in popliteal arteries leads to favorable technical and clinical results at 1 year for claudicant as well as CLI patients.

  4. Restenosis after hot-tip laser-balloon angioplasty: histologic evaluation of the samples removed by Simpson atherectomy

    NASA Astrophysics Data System (ADS)

    Barbieri, Enrico; Tanganelli, Pietro; Taddei, Giuseppe; Perbellini, Antonio; Attino, Vito; Destro, Gianni; Zardini, Piero

    1991-05-01

    Laser balloon angioplasty has been used in recent years to treat peripheral artery disease. Despite a primary success the technique is plagued by a high restenosis rate. Directional atherectomy was performed in a small group of patients affected by primitive stenosis or restenosis after an invasive procedure. Light microscopy, immunohistochemistry, and transmission electron microscopy have identified the cellular component of intimal hyperplasia as smooth muscle cells in an active synthetic phenotype. The arterial healing process after invasive procedures seems to develop similarly independently of the device employed.

  5. Immediate and intermediate-term results of optical coherence tomography guided atherectomy in the treatment of peripheral arterial disease: Initial results from the VISION trial.

    PubMed

    Cawich, Ian; Paixao, Andre R M; Marmagkiolis, Konstantinos; Lendel, Vasili; Rodriguez-Araujo, Gerardo; Rollefson, William A; Mego, David M; Cilingiroglu, Mehmet

    Long-term patency rates for percutaneous peripheral arterial interventions are suboptimal. Optical coherence tomography (OCT) guided atherectomy may yield superior patency by optimizing plaque removal while preserving the tunica media and adventitia. The VISION study is a multicenter prospective study of patients with peripheral arterial disease undergoing OCT guided atherectomy with the Pantheris™ device. In 11 patients enrolled in a single center, we report procedural and clinical outcomes, at 30days and 6months. The mean age was 63±11years and 73% (n=8) were men. The target lesion was in the superficial femoral artery in 82% (n=9) of the patients. Mean stenosis severity was 87%±10% and mean lesion length was 39±31mm. Procedural success was observed in all patients with no device related complications. Mean post-atherectomy stenosis was 18%±15%. Almost all excised tissue consisted of intimal plaque (94%). At 30days, significant improvements in Rutherford class, VascuQoL scores and ABI were observed, 0.9±0.8 vs. 3.1±0.7 (p=0.01), 4.9±1.9 vs. 3.6±1.5 (p=0.03) and 1.04±0.19 vs. 0.80±0.19 (p<0.01) respectively. At 6months, there were significant improvements in Rutherford class (1.0±1.0 vs. 3.1±0.7, p=0.01) and ABI (0.93±0.19 versus 0.80±0.19, p=0.02) but not in VascuQoL scores (3.7±1.4 versus 3.6±1.5, p=0.48). Target lesion revascularization occurred in 18% (n=2) of the patients. OCT guided atherectomy resulted in high procedural success, no device related complications and encouraging results up to 6months. Histological analysis suggested little injury to the media and adventitia. Larger studies are needed to confirm the efficacy of this approach. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Neointimal Hyperplasia after Silverhawk Atherectomy versus Percutaneous Transluminal Angioplasty (PTA) in Femoropopliteal Stent Reobstructions: A Controlled, Randomized Pilot Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brodmann, Marianne, E-mail: marianne.brodmann@medunigraz.at; Rief, Peter; Froehlich, Harald

    2013-02-15

    Due to intimal hyperplasia instent reobstruction in the femoropopliteal arterial segment is still an unsolved problem. Different techniques have been discussed in case of reintervention to guarantee longlasting patency rate. We conducted a randomized, controlled, pilot trial comparing Silverhawk atherectomy with percutaneous transluminal angioplasty (PTA) in patients with a first instent reobstruction in the femoropopliteal arterial segment, to evaluate intima media thickness (IMT) within the treated segment, as a parameter of recurrence of intimal hyperplasia. In a total 19 patients were included: 9 patients in the atherectomy device and 10 patients in the PTA arm. IMT within the treated segmentmore » was statistically significantly elevated in all patients treated with the Silverhawk device versus the patients treated with PTA. The obvious differentiation in elevation of IMT in nonfavor for patients treated with the Silverhawk device started at month 2 (max IMT SH 0.178 mm vs. IMT PTA 0.1 mm, p = 0.001) with a spike at month 5 (max IMT SH 0.206 mm vs. IMT PTA 0.145 mm, p = 0.003) and a decline once again at month 6 (max IMT SH 0.177 mm vs. IMT PTA 0.121 mm, p = 0.02). The values for mean IMT performed the same way. Although Silverhawk atherectomy provides good results at first sight, in the midterm follow-up of treatment of first instent restenosis it did not perform better than PTA as it showed elevated reoccurrence of intimal media hyperplasia.« less

  7. Neointimal hyperplasia after silverhawk atherectomy versus percutaneous transluminal angioplasty (PTA) in femoropopliteal stent reobstructions: a controlled, randomized pilot trial.

    PubMed

    Brodmann, Marianne; Rief, Peter; Froehlich, Harald; Dorr, Andreas; Gary, Thomas; Eller, Philipp; Hafner, Franz; Deutschmann, Hannes; Seinost, Gerald; Pilger, Ernst

    2013-02-01

    Due to intimal hyperplasia instent reobstruction in the femoropopliteal arterial segment is still an unsolved problem. Different techniques have been discussed in case of reintervention to guarantee longlasting patency rate. We conducted a randomized, controlled, pilot trial comparing Silverhawk atherectomy with percutaneous transluminal angioplasty (PTA) in patients with a first instent reobstruction in the femoropopliteal arterial segment, to evaluate intima media thickness (IMT) within the treated segment, as a parameter of recurrence of intimal hyperplasia. In a total 19 patients were included: 9 patients in the atherectomy device and 10 patients in the PTA arm. IMT within the treated segment was statistically significantly elevated in all patients treated with the Silverhawk device versus the patients treated with PTA. The obvious differentiation in elevation of IMT in nonfavor for patients treated with the Silverhawk device started at month 2 (max IMT SH 0.178 mm vs. IMT PTA 0.1 mm, p = 0.001) with a spike at month 5 (max IMT SH 0.206 mm vs. IMT PTA 0.145 mm, p = 0.003) and a decline once again at month 6 (max IMT SH 0.177 mm vs. IMT PTA 0.121 mm, p = 0.02). The values for mean IMT performed the same way. Although Silverhawk atherectomy provides good results at first sight, in the midterm follow-up of treatment of first instent restenosis it did not perform better than PTA as it showed elevated reoccurrence of intimal media hyperplasia.

  8. Lower Extremity Revascularization Using Optical Coherence Tomography-Guided Directional Atherectomy: Final Results of the EValuatIon of the PantheriS OptIcal COherence Tomography ImagiNg Atherectomy System for Use in the Peripheral Vasculature (VISION) Study.

    PubMed

    Schwindt, Arne G; Bennett, J Gray; Crowder, William H; Dohad, Suhail; Janzer, Sean F; George, Jon C; Tedder, Barry; Davis, Thomas P; Cawich, Ian M; Gammon, Roger S; Muck, Patrick E; Pigott, John P; Dishmon, Dwight A; Lopez, Lou A; Golzar, Jaafer A; Chamberlin, Jack R; Moulton, Michael J; Zakir, Ramzan M; Kaki, Amir K; Fishbein, Gary J; McDaniel, Huey B; Hezi-Yamit, Ayala; Simpson, John B; Desai, Arjun

    2017-06-01

    To evaluate the safety and efficacy of a novel optical coherence tomography (OCT)-guided atherectomy catheter in treating patients with symptomatic femoropopliteal disease. The VISION trial ( ClinicalTrials.gov identifier NCT01937351) was a single-arm, multicenter, global investigational device exemption study enrolling 158 subjects (mean age 67.2±10.5 years; 87 men) across 20 participating sites. In this cohort, 198 lesions were treated with an average length of 53±40 mm using the Pantheris catheter alone or Pantheris + adjunctive therapy. The primary safety endpoint was the composite of major adverse events (MAEs) through 6 months (objective performance goal 43.2%). Technical success (primary efficacy outcome) was defined as the percent of target lesions with a residual diameter stenosis ≤50% after treatment with the Pantheris device alone (objective performance goal 87.0%). Procedural success was defined as reduction in stenosis to ≤30% after Pantheris ± adjunctive therapy. Tissue specimens retrieved from each treated lesion were histologically analyzed to evaluate the accuracy and precision of OCT image guidance. The primary efficacy outcome was achieved in 192 (97.0%) of the 198 lesions treated with the Pantheris catheter. Across all lesions, mean diameter stenosis was reduced from 78.7%±15.1% at baseline to 30.3%±11.8% after Pantheris alone (p<0.001) and to 22.4%±9.9% after Pantheris ± adjunctive therapy (p<0.001). Of the 198 target lesions, 104 (52.5%) were treated with the Pantheris alone, 84 (42.4%) were treated with Pantheris + adjunctive angioplasty, and 10 (5.1%) with Pantheris + angioplasty + stenting. The composite MAE outcome through 6 months occurred in 25 (16.6%) of 151 subjects. There were no clinically significant perforations, 1 (0.5%) catheter-related dissection, 4 (2%) embolic events, and a 6.4% clinically driven target lesion revascularization rate at 6 months. The 40-lesion chronic total occlusion (CTO) subset (mean lesion length 82±38 mm) achieved a similar significant reduction in stenosis to 35.5%±13.6% after Pantheris alone (p<0.001). Histological analysis of atherectomy specimens confirmed <1% adventitia in 82.1% of the samples, highlighting the precision of OCT guidance. Characterization of the OCT-guided lesions revealed evidence of an underestimation of disease burden when using fluoroscopy. OCT-guided atherectomy for femoropopliteal disease is safe and effective. Additionally, the precision afforded by OCT guidance leads to greater removal of plaque during atherectomy while sparing the adventitia.

  9. Impact of lesion location on procedural and acute angiographic outcomes in patients with critical limb ischemia treated for peripheral artery disease with orbital atherectomy: A CONFIRM registries subanalysis.

    PubMed

    Lee, Michael S; Mustapha, Jihad; Beasley, Robert; Chopra, Paramjit; Das, Tony; Adams, George L

    2016-02-15

    This analysis compares the procedural and acute angiographic outcomes in patients with critical limb ischemia (CLI) treated with orbital atherectomy in above-the-knee (ATK)/popliteal (POP) lesions versus below-the-knee (BTK) lesions. Lesion location affects the procedural outcomes and the opportunity for limb salvage in patients with CLI suffering from peripheral artery disease (PAD). The CONFIRM registry series was analyzed and includes 1109 real-world patients (1544 lesions) suffering from CLI treated with orbital atherectomy. The rates of dissection, perforation, slow flow, vessel closure, spasm, embolism, and thrombus formation were compared between CLI patients with ATK/POP lesions and BTK lesions. Patients with ATK/POP lesions had a higher final residual stenosis (10 vs. 9%; P = 0.004) and use of more adjunctive therapies (e.g. balloons and stents; 1.3 vs. 1.1%; P < 0.001) compared to patients with BTK lesions. Patients with BTK had higher incidence of perforation (1.5 vs. 0.2%; P = 0.005), slow flow (7.7 vs. 5.0%; P = 0.03) and spasm (10.3 vs. 4.2%; P < 0.001) but lower incidence of embolism (0.4 vs. 5.1%; P < 0.001). Plaque modification with orbital atherectomy was successful in CLI patients regardless of lesion location. BTK lesions were associated with increased rates of perforation, slow flow and spasm which may be explained by more challenging procedural characteristics in these patients such as smaller vessel size and tortuosity. The higher incidence of emboli in ATK/POP lesions is most likely attributed to the higher prevalence of severe calcium observed in this cohort. © 2015 Wiley Periodicals, Inc.

  10. Expression of IGF-I, IGF-I receptor and IGF binding proteins-1, -2, -3, -4 and -5 in human atherectomy specimens.

    PubMed

    Grant, M B; Wargovich, T J; Ellis, E A; Tarnuzzer, R; Caballero, S; Estes, K; Rossing, M; Spoerri, P E; Pepine, C

    1996-12-17

    The molecular and cellular processes that induce rapid atherosclerotic plaque progression in patients with unstable angina and initiate restenosis following coronary interventional procedures are uncertain. We examined primary (de novo) and restenotic lesions retrieved at the time of directional coronary atherectomy for expression of insulin-like-growth factor-I (IGF-I). IGF-I receptor, and five IGF binding proteins (IGFBPs), IGFBP-1, IGFBP-2, IGFBP-3, IGFBP-4, and IGFBP-5 in smooth muscle cells (SMCs) using colloidal gold immunocytochemistry. IGF-1, its receptor and binding proteins were not detected in SMCs of normal coronary arteries. IGF-I localized primarily in synthetic smooth muscle cells (sSMCs) in both de novo and restenotic plaques. IGF-I receptor localized on sSMCs and their processes and colocalized with IGF-I. Although morphometric analysis of IGF-I and IGF-I receptor immunoreactivity in sSMCs of de novo and restenotic lesions showed comparable levels of IGF-I (3.2 +/- 1.0 and 2.9 +/- 0.9, respectively). IGF-I receptor was significantly higher in de novo lesions as compared to restenotic lesions (10.7 +/- 2.5 and 4.2 +/- 1.3, P < 0.05, respectively). IGFBP-1, IGFBP-2, IGFBP-3, IGFBP-4 and IGFBP-5 localized in the cytoplasm of sSMCs and in the extracellular matrix. Quantitative reverse transcription polymerase chain reaction (QRT-PCR) performed on de novo atherectomy specimens identified mRNA for IGF-I, IGF-I receptor, IGFBP-1, IGFBP-2, IGFBP-4, IGFBP-5 levels and detected mRNA for IGFBP-3. The expression of IGF-I, IGF-I receptor, and IGFBPs in atherectomy plaques suggests that the development of coronary obstructive lesions may be a result of changes in the IGF system.

  11. Improved liquid-film electron stripper

    DOEpatents

    Gavin, B.F.

    1984-11-01

    An improved liquid-film electron stripper particularly for high intensity heavy ion beams which produces constant regenerated, stable, free-standing liquid films having an adjustable thickness between 0.3 to 0.05 microns. The improved electron stripper is basically composed of at least one high speed, rotating disc with a very sharp, precision-like, ground edge on one side of the disc's periphery and with highly polished, flat, radial surface adjacent the sharp edge. A fine stream of liquid, such as oil, impinges at a 90/sup 0/ angle adjacent the disc's sharp outer edge. Film terminators, located at a selected distance from the disc perimeter are positioned approximately perpendicular to the film. The terminators support, shape, and stretch the film and are arranged to assist in the prevention of liquid droplet formation by directing the collected film to a reservoir below without breaking or interfering with the film. One embodiment utilizes two rotating discs and associated terminators, with the discs rotating so as to form films in opposite directions, and with the second disc being located down beam-line relative to the first disc.

  12. Liquid-film electron stripper

    DOEpatents

    Gavin, Basil F.

    1986-01-01

    An improved liquid-film electron stripper particularly for high intensity heavy ion beams which produces constant regenerated, stable, free-standing liquid films having an adjustable thickness between 0.3 to 0.05 microns. The improved electron stripper is basically composed of at least one high speed, rotating disc with a very sharp, precision-like, ground edge on one said of the disc's periphery and with a highly polished, flat, radial surface adjacent the sharp edge. A fine stream of liquid, such as oil, impinges at a 90.degree. angle adjacent the disc's sharp outer edge. Film terminators, located at a selected distance from the disc perimeter are positioned approximately perpendicular to the film. The terminators support, shape, and stretch the film and are arranged to assist in the prevention of liquid droplet formation by directing the collected film to a reservoir below without breaking or interfering with the film. One embodiment utilizes two rotating discs and associated terminators, with the discs rotating so as to form films in opposite directions, and with the second disc being located down beam-line relative to the first disc.

  13. Impact of Angioscopic Evaluation for Femoropopliteal In-Stent Restenosis Before and After Excimer Laser Atherectomy.

    PubMed

    Idemoto, Akiko; Okamoto, Naotaka; Tanaka, Akihiro; Mori, Naoki; Nakamura, Daisuke; Yano, Masamichi; Makino, Nobuhiko; Egami, Yasuyuki; Shutta, Ryu; Tanouchi, Jun; Nishino, Masami

    2017-07-01

    In-stent restenosis (ISR) is a prevalent problem following stenting of femoropopliteal lesions. A potential novel treatment modality for ISR including excimer laser atherectomy (ELA) has become available. We performed ELA for in-stent chronic total occlusion (CTO) of femoropopliteal lesions and evaluated lesion morphology before and after ELA by angioscopy in 2 patients. The angioscopic findings clearly showed removal of in-stent thrombi after ELA. Thus, ELA may be effective for in-stent CTO of femoropopliteal lesions. This is the first report describing the direct visualization of ELA effect for vaporization of thrombi in femoropopliteal in-stent lesions by angioscopy.

  14. Orbital atherectomy for the treatment of severely calcified coronary lesions: evidence, technique, and best practices.

    PubMed

    Shlofmitz, Evan; Martinsen, Brad J; Lee, Michael; Rao, Sunil V; Généreux, Philippe; Higgins, Joe; Chambers, Jeffrey W; Kirtane, Ajay J; Brilakis, Emmanouil S; Kandzari, David E; Sharma, Samin K; Shlofmitz, Richard

    2017-11-01

    The presence of severe coronary artery calcification is associated with higher rates of angiographic complications during percutaneous coronary intervention (PCI), as well as higher major adverse cardiac events compared with non-calcified lesions. Incorporating orbital atherectomy (OAS) for effective preparation of severely calcified lesions can help maximize the benefits of PCI by attaining maximal luminal gain (or stent expansion) and improve long-term outcomes (by reducing need for revascularization). Areas covered: In this manuscript, the prevalence, risk factors, and impact of coronary artery calcification on PCI are reviewed. Based on current data and experience, the authors review orbital atherectomy technique and best practices to optimize lesion preparation. Expert Commentary: The coronary OAS is the only device approved for use in the U.S. as a treatment for de novo, severely calcified coronary lesions to facilitate stent delivery. Advantages of the device include its ease of use and a mechanism of action that treats bi-directionally, allowing for continuous blood flow during treatment, minimizing heat damage, slow flow, and subsequent need for revascularization. The OAS technique tips reviewed in this article will help inform interventional cardiologists treating patients with severely calcified lesions.

  15. Angioscopic assessment of various percutaneous treatments for arteriosclerosis obliterance

    NASA Astrophysics Data System (ADS)

    Kusaba, Hiroyasu; Watanabe, Kazuo; Shiraishi, Shohzo; Sato, Takashi; Koga, Nobuhiko

    1993-06-01

    We have evaluated the angioscopic findings before and after various percutaneous techniques to treat 39 lesions in 32 cases of arteriosclerosis obliterans (ASO). We applied a laser (CL50: SLT, Japan), percutaneous transluminal angioplasty (PTA), and atherectomy -- either singly or in combination, with angioscopic luminal observation (angioscope: PF14L & PF18L Olympus, Japan) recorded before and after the treatments. In the case of a complete obstruction, we employed PTA as the first choice. We used a laser prior to PTA when the PTA guide-wire failed to penetrate the lumen. For eccentric and calcified lesions atherectomy was applied. A sufficient enlargement was obtained initially in 37 of the 39 lesions. The angioscopic observations after treatment revealed carbonization (3/5) and attachment of small thrombi (3/5) after using the laser, intimal rupture (3/8), dissection (2/8), flap formation (2/8), and attachment of small thrombi (4/8) after PTA, and attachment of small thrombi (9/19), flap formation (6/19), and dissection (2/19) after atherectomy. We established the efficacy of angioscopic assessment demonstrating beneficial clinical results. The angioscopic findings suggest that attachment of small thrombi may be responsible for a poor prognosis. Additional angioscopic observations with angiography are recommended for improved understanding of the luminal changes.

  16. Pooled analysis of the CONFIRM registries: safety outcomes in diabetic patients treated with orbital atherectomy for peripheral artery disease.

    PubMed

    Lee, Michael S; Yang, Tae; Adams, George

    2014-04-01

    To compare the acute outcomes of orbital atherectomy treatment in diabetic vs. non-diabetic patients with peripheral artery disease (PAD). The CONFIRM registry series contained 1842 diabetic patients (1111 men; mean age 70.6±10.2 years) with 2819 lesions and 1247 non-diabetic patients (732 men; mean age 72.9±10.7 years) with 1885 lesions. The composite rate of procedure-related complications, including dissection, perforation, slow flow, vessel closure, spasm, embolism, and thrombus formation, was analyzed for the diabetic and non-diabetic groups. Diabetics were younger but had a higher prevalence of coronary artery disease (p<0.001), renal disease (p<0.001), hypertension (p<0.001), hyperlipidemia (p<0.001), and lower ankle-brachial index scores (p=0.007). Diabetics had more severe PAD (Rutherford category 4-6; p<0.001), longer lesions (p<0.001), more infrapopliteal lesions (58% vs. 46%, p<0.001), and more lesions with severe and moderate calcium (86% vs. 78%, p<0.001). Diabetic and non-diabetic patients had the same (21.8%) composite rate of procedure-related complications, as well as similar rates of dissection (11.4% vs. 10.8%, p=0.68), embolism (2.2% vs. 2.4%, p=0.67), and thrombus formation (1.3% vs. 1.1%, p=0.75). However, diabetics had lower rates of perforation (0.5% vs. 1.1%, p=0.03) and spasm (5.5% vs. 7.6%, p=0.005), but a higher rate of slow flow (5.0% vs. 3.5%, p=0.02) and a tendency toward increased vessel closure (1.7% vs. 0.9%, p=0.06). Plaque modification with orbital atherectomy resulted in similar low procedure-related complication rates in both the diabetic and non-diabetic groups, despite diabetics having more unfavorable baseline clinical and lesion characteristics. This study suggests that orbital atherectomy is a safe and effective treatment modality in both the diabetic and the non-diabetic populations.

  17. A comparative study of percutaneous atherectomy for femoropopliteal arterial occlusive disease.

    PubMed

    Gu, Yongquan; Malas, Mahmoud B; Qi, Lixing; Guo, Lianrui; Guo, Jianming; Yu, Hengxi; Tong, Zhu; Gao, Xixiang; Zhang, Jian; Wang, Zhonggao

    2017-08-01

    SilverHawk™ directional atherectomy has been used to treat more than 300 thousand cases of lower extremity atherosclerotic occlusive disease in the world since it was approved by FDA in 2003. This study aimed to analyze the safety and effectiveness of symptomatic femoral popliteal atherosclerotic disease treated by directional atherectomy (DA). Clinical data of all consecutive patients treated with percutaneous atherectomy utilizing the SilverHawk™ plaque excision was retrospectively analyzed. The anatomic criteria of the atherosclerotic lesions were divided into four types: type I stenosis; type II occlusion; type III in-stent restenosis; type IV stent occlusion. There were 160 patients treated during the study period. Intermittent claudication in 75 patients (47%), rest pain in 55 patients (34.5%) and tissue loss in 30 patients (18.5%). The number of patients was 72, 15, 49 and 24 in type I, II, III and IV lesions, respectively. Technical success rate was 98.6%, 93.3%, 97.9% and 91.7% in type I, II, III and IV lesions, respectively. Debris of intimal plaque was captured by protection device in 92 patients (71.3%). The mean follow-up period was 23.5±10.4 months. Restenosis rate of type I to IV lesions was 21%, 36%, 36% and 40% respectively. Restenosis rate in type I lesion was significantly lower than that in type III and IV lesions (P<0.05). Patients with tissue loss responded to revascularization as follow: type I, 11/13 healed or reduced (84.6%), type II, 3/3 patients improved (100%), type III, 5/6 patients improved (83.3%) and type IV 4/4 healed (100%). In type IV group, four patients had in-stent thrombosis found by postoperative Duplex ultrasonography. They all underwent DA after catheter-directed thrombolysis with good angiographic results. Percutaneous DA is safe and effective for both de-novo atherosclerotic and in-stent stenotic or occlusive lesions. Thrombolysis before plaque excision is recommended in case of in-stenting thrombosis.

  18. Laser angioplasty for cardiovascular disease

    NASA Astrophysics Data System (ADS)

    Okada, Masayoshi

    2005-07-01

    Recently, endovascular interventions such as balloon angioplasty, atherectomy and the stenting method, except for conventional surgery have been clinically employed for the patients with atheromatous plaques of the peripheral- and the coronary arteries, because the number of patients with arteriosclerosis is now increasing in the worldwide. Among these procedures, restenoses after endovascular interventions have been remarkably disclosed in 20-40 % of the patients who underwent percutaneous coronary interventions. Thus, there are still some problems in keeping long-term patency by means of endovascular techniques such as balloon angioplasty and atherectomy (1, 2). For reduction of these problems , laser angioplasty using Argon laser was applied experimentally and clinically. Based on excellent experimental studies, laser was employed for 115 patients with stenotic ,or obstructive lesions occluding more thasn 75 % of the peripheral and the coronary arteries angiographycally.

  19. Pre-processing, registration and selection of adaptive optics corrected retinal images.

    PubMed

    Ramaswamy, Gomathy; Devaney, Nicholas

    2013-07-01

    In this paper, the aim is to demonstrate enhanced processing of sequences of fundus images obtained using a commercial AO flood illumination system. The purpose of the work is to (1) correct for uneven illumination at the retina (2) automatically select the best quality images and (3) precisely register the best images. Adaptive optics corrected retinal images are pre-processed to correct uneven illumination using different methods; subtracting or dividing by the average filtered image, homomorphic filtering and a wavelet based approach. These images are evaluated to measure the image quality using various parameters, including sharpness, variance, power spectrum kurtosis and contrast. We have carried out the registration in two stages; a coarse stage using cross-correlation followed by fine registration using two approaches; parabolic interpolation on the peak of the cross-correlation and maximum-likelihood estimation. The angle of rotation of the images is measured using a combination of peak tracking and Procrustes transformation. We have found that a wavelet approach (Daubechies 4 wavelet at 6th level decomposition) provides good illumination correction with clear improvement in image sharpness and contrast. The assessment of image quality using a 'Designer metric' works well when compared to visual evaluation, although it is highly correlated with other metrics. In image registration, sub-pixel translation measured using parabolic interpolation on the peak of the cross-correlation function and maximum-likelihood estimation are found to give very similar results (RMS difference 0.047 pixels). We have confirmed that correcting rotation of the images provides a significant improvement, especially at the edges of the image. We observed that selecting the better quality frames (e.g. best 75% images) for image registration gives improved resolution, at the expense of poorer signal-to-noise. The sharpness map of the registered and de-rotated images shows increased sharpness over most of the field of view. Adaptive optics assisted images of the cone photoreceptors can be better pre-processed using a wavelet approach. These images can be assessed for image quality using a 'Designer Metric'. Two-stage image registration including correcting for rotation significantly improves the final image contrast and sharpness. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  20. Dynamical mechanism for sharp orientation tuning in an integrate-and-fire model of a cortical hypercolumn.

    PubMed

    Bressloff, P C; Bressloff, N W; Cowan, J D

    2000-11-01

    Orientation tuning in a ring of pulse-coupled integrate-and-fire (IF) neurons is analyzed in terms of spontaneous pattern formation. It is shown how the ring bifurcates from a synchronous state to a non-phase-locked state whose spike trains are characterized by clustered but irregular fluctuations of the interspike intervals (ISIs). The separation of these clusters in phase space results in a localized peak of activity as measured by the time-averaged firing rate of the neurons. This generates a sharp orientation tuning curve that can lock to a slowly rotating, weakly tuned external stimulus. Under certain conditions, the peak can slowly rotate even to a fixed external stimulus. The ring also exhibits hysteresis due to the subcritical nature of the bifurcation to sharp orientation tuning. Such behavior is shown to be consistent with a corresponding analog version of the IF model in the limit of slow synaptic interactions. For fast synapses, the deterministic fluctuations of the ISIs associated with the tuning curve can support a coefficient of variation of order unity.

  1. The role of atherectomy in the treatment of lower extremity peripheral artery disease

    PubMed Central

    2012-01-01

    Background The incidence of lower extremity peripheral artery disease (LE-PAD) continues to increase and associated morbidity remains high. Despite the significant development of percutaneous revascularization strategies, over the past decade, LE-PAD still represents a unique challenge for interventional cardiologists and vascular surgeons. Method Typical features of atherosclerosis that affects peripheral vascular bed (diffuse nature, poor distal runoff, critical limb ischemia, chronic total occlusion) contribute to the disappointing results of traditional percutaneous transluminal angioplasty (PTA). New technologies have been developed in attempt to improve the safety and effectiveness of percutaneous revascularization. Among these, atherectomy, debulking and removing atherosclerotic plaque, offers the potential advantage of eliminating stretch on arterial walls and reducing rates of restenosis. Conclusions This review summarizes the features and the current applications of new debulking devices. PMID:23173800

  2. Acute procedural outcomes of orbital atherectomy for the treatment of common femoral artery disease: Sub-analysis of the CONFIRM Registries.

    PubMed

    Lee, Michael S; Heikali, Daniel; Mustapha, Jihad; Adams, George; Mahmud, Ehtisham

    2017-08-01

    This analysis compared the angiographic outcomes of patients treated with orbital atherectomy for calcified common femoral artery (CFA) and superficial femoral artery (SFA) disease. The ideal revascularization strategy for CFA disease is unknown. Endarterectomy has been considered the standard of care for CFA disease for over 50 years. Endovascular intervention is becoming more commonly used to revascularize the CFA given the advances in technology and the less invasive nature of the procedure. Patient demographics, lesion characteristics, and procedure data for all CONFIRM patients with at least one CFA lesion location ( n=147 patients; n=200 lesions) were compared to patients with at least one SFA lesion location ( n=1508 patients; n=2367 lesions). The primary endpoint was angiographic complication, defined as the composite of dissection, perforation, slow flow, closure, spasm, embolism, or thrombosis. The CFA group had more patients with Rutherford class 4 and shorter lesion length. The CFA group had a higher final residual stenosis, shorter total run time, and shorter total inflation time. The primary endpoint was lower in the CFA group compared with the SFA group (17% vs 24%, p=0.02), driven by a lower dissection rate (10% vs 15%, p=0.04). Plaque modification of the CFA with orbital atherectomy was safe and compared favorably with SFA disease. The need for bail-out stenting was low. A randomized trial is needed to determine the ideal treatment strategy for calcified CFA disease.

  3. Rotation Periods of Open Cluster Stars. IV.

    NASA Astrophysics Data System (ADS)

    Prosser, Charles F.; Grankin, Konstantin N.

    We present the results from a photometric monitoring program of primarily solar-type open cluster stars obtained during 1994 and 1995. Several members of the α Persei cluster have been monitored and the corresponding relation between coronal x-ray activity and rotation period derived. The relation among mid-G/K type members illustrates both the previously noticed downturn in L_X/L_bol at high rotation rates and the sharp decrease in coronal activity at long rotation periods as seen among Pleiades stars. Intensive observation of one slowly rotating G-type member of IC 4665 has enabled a period determination of 8-10 days to be made and illustrates the need for (and limitations of) high quality observations.

  4. Use of orbital atherectomy in acute myocardial infarction via the transradial approach

    PubMed Central

    Mowakeaa, Samer; Snyder, Branden; Kakouros, Nikolaos

    2016-01-01

    Severe coronary artery calcifications pose an ongoing challenge when performing percutaneous coronary interventions, resulting in an increased likelihood of procedural complications. Orbital atherectomy (OA) has emerged as a promising technology that helps improve outcomes in this complex patient population. Its safety and efficacy are yet to be demonstrated in the setting of acute myocardial infarction. We present a case of a patient with acute ST-elevation myocardial infarction (STEMI) evaluated with emergent transradial coronary angiography. The culprit lesion was a severely stenotic, heavily calcified, segment of the right coronary artery. The use of OA facilitated lesion expansion and implantation of a drug-eluting stent. Although OA should be considered as contraindicated for the management of soft-ruptured plaque, which accounts for the majority of STEMI presentations, it may be well applied to the small subset of patients with calcified nodule pathology, even in the acute setting. PMID:28180008

  5. Determining Angular Frequency from Video with a Generalized Fast Fourier Transform

    DTIC Science & Technology

    2012-03-22

    depicted in the first row, where n = (0, . . . , 7). It turns out the Mercedes - Benz shape in these images is rotating by a factor of 3(2π 8 ) radians in...a GST rotation example of data length N = 8 applied to the Mercedes - Benz shape. The first row is the original X sequence. Each column under that...rate of rotation by computing the sharpness of the sum. In Figure 2, GST(X[3]) appears to be the sharpest GST image; this confirms that the Mercedes

  6. Liquid-film electron stripper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gavin, B.F.

    1986-12-02

    This patent describes an improved liquid-film electron stripper for high intensity heavy ion beams comprising: at least one rotatable disc mounted in a housing, means for rotating the disc, a liquid reservoir operatively connected to the housing, means for directing liquid from the reservoir onto the rotatable disc for forming a film of liquid as liquid is spun from the disc, the disc being configured to define a sharp edge located at one side of the periphery of the disc, and configured to include a flat, smooth radially outer section located adjacent the sharp edge, the liquid being directed ontomore » the flat, smooth section of the disc, the means for directing liquid onto the disc including a nozzle positioned with respect to the disc so that liquid from the nozzle impinges at about a 90/sup 0/ angle with respect to the flat, smooth surface of the disc, and liquid film terminator means located in spaced relation to the disc and approximately perpendicular to a formed liquid film, the terminator means comprising at least one ribbon of material secured to the housing.« less

  7. Method of making hollow elastomeric bodies

    NASA Technical Reports Server (NTRS)

    Broyles, H. F.; Moacanin, J.; Cuddihy, E. F. (Inventor)

    1976-01-01

    Annular elastomeric bodies having intricate shapes are cast by dipping a heated, rotating mandrel into a solution of the elastomer, permitting the elastomer to creep into sharp recesses, drying the coated mandrel and repeating the operation until the desired thickness has been achieved. A bladder for a heart assist pump in which a cylindrical body terminating in flat, sharp horizontal flanges fabricated by this procedure has been subjected to over 2,500 hours of simulated life conditions with no visible signs of degradation.

  8. Quantum rotations in natural methane-clathrates from the Pacific sea-floor

    NASA Astrophysics Data System (ADS)

    Gutt, C.; Asmussen, B.; Press, W.; Merkl, C.; Casalta, H.; Greinert, J.; Bohrmann, G.; Tse, J. S.; Hüller, A.

    1999-11-01

    We report inelastic neutron scattering experiments from natural methane hydrates sampled from the Pacific sea-floor during an expedition of the research ship SONNE. The experiments verify directly the content of methane by measuring the rotational spectrum of the CH4 molecules. The existence of almost free rotational levels excludes off-center positions of the molecules in the cages. In addition we could assign the observed peaks in the energy regime up to 5 meV to rotational excitations only. The observed relative sharp excitations prove a surprisingly good crystallinity of the geological sample. The finite width is attributed to frozen-in hydrogen disorder of the ice cages.

  9. One-Year Outcomes Following Directional Atherectomy of Infrapopliteal Artery Lesions: Subgroup Results of the Prospective, Multicenter DEFINITIVE LE Trial.

    PubMed

    Rastan, Aljoscha; McKinsey, James F; Garcia, Lawrence A; Rocha-Singh, Krishna J; Jaff, Michael R; Noory, Elias; Zeller, Thomas

    2015-12-01

    To report a subgroup analysis of the prospective, multicenter, single-arm DEFINITIVE LE trial to assess the effectiveness of directional atherectomy for the treatment of infrapopliteal artery lesions at 1 year. In the DEFINITIVE LE trial, follow-up assessments occurred up to 1 year postprocedure. Of the 800 patients enrolled, 145 subjects with 189 infrapopliteal lesions met the criteria for this analysis. Seventy (48.3%) and 75 (51.7%) patients were suffering critical limb ischemia (CLI) and intermittent claudication, respectively; 68.3% (99/145) had diabetes. The mean lesion length was 58±44 mm (all lesions); 20.2% were occluded. The primary endpoint for patients with claudication was duplex ultrasound-derived primary patency, while for subjects with CLI it was freedom from major amputation of the target limb at 1 year. Endpoints and adverse events were independently assessed. Procedure success (≤30% residual stenosis) was achieved in 84% of treated lesions. The 1-year primary patency rate was 84% (claudicants 89.6% and CLI patients 78%, p=0.11), and the freedom from major amputation rate was 97.1% (claudicants 100% and CLI 93.8%, p=0.03). In both claudication and CLI patients, significant improvements in Rutherford category and objective measures of walking distance and quality of life were seen at 1 year in comparison to baseline. This study demonstrates that directional atherectomy in infrapopliteal arteries results in promising technical and clinical results at 1 year for claudicant as well as CLI patients. © The Author(s) 2015.

  10. Successful retrieval of an entrapped Rotablator burr using 5 Fr guiding catheter.

    PubMed

    Kimura, Masayoshi; Shiraishi, Jun; Kohno, Yoshio

    2011-10-01

    Although burr entrapment is a rare complication of the Rotablator, it is extremely difficult to retrieve a fixedly entrapped burr without surgical procedure. An 84-year-old male with effort angina had heavily calcified coronary trees as well as severe stenosis in the mid LCx, and moderate stenosis in the proximal LCx, and in the LMT. We planned to perform rotational atherectomy in the LCx lesions. Using 7 Fr Q-curve guiding catheter and Rotawire floppy, we began to ablate using 1.5-mm burr at 200,000 rpm. Because the burr could not pass the proximal stenosis, we exchanged the wire for Rotawire extrasupport and the burr for 1.25-mm burr, and restarted the ablation at 220,000 rpm. Although the burr could manage to pass the proximal stenosis, it had become trapped in the mid LCx lesion. Simple pull on the Rotablator, rotation of the burr, and crossing the Conquest (Confianza) wire could not retrieve it. Thus, we cut off the drive shaft and sheath of the Rotablator, inserted 5 Fr 120-cm straight guiding catheter (Heartrail ST01; Terumo) through the remaining Rotablator system, pushed the catheter tip to the lesion around the burr as well as simultaneously pulled the Rotablator, and finally could retrieve it. Then we implanted stents in the LCx and in the LMT without difficulty. The 5 Fr straight guiding catheter might be useful for retrieving an entrapped burr (1.25-mm burr). Copyright © 2011 Wiley-Liss, Inc.

  11. Boiler for generating high quality vapor

    NASA Technical Reports Server (NTRS)

    Gray, V. H.; Marto, P. J.; Joslyn, A. W.

    1972-01-01

    Boiler supplies vapor for use in turbines by imparting a high angular velocity to the liquid annulus in heated rotating drum. Drum boiler provides a sharp interface between boiling liquid and vapor, thereby, inhibiting the formation of unwanted liquid droplets.

  12. Pooled analysis of the CONFIRM Registries: outcomes in renal disease patients treated for peripheral arterial disease using orbital atherectomy.

    PubMed

    Lee, Michael S; Yang, Tae; Adams, George L; Mustapha, Jihad; Das, Tony

    2014-08-01

    Patients with renal disease typically have severely calcified peripheral arterial disease. As a result, this population may have worse clinical outcomes following endovascular intervention compared to patients without renal insufficiency. Clinical trials typically exclude this patient population. Analysis of the CONFIRM I-III registries revealed 1105 patients with renal disease (1777 lesions) and 1969 patients without renal disease (2907 lesions) who underwent orbital atherectomy. This subanalysis compared the composite procedural complication rate including dissection, perforation, slow flow, vessel closure, spasm, embolism, and thrombus formation in patients with and without renal disease. Patients with renal disease had a higher prevalence of diabetes (P<.001), hypertension (P<.001), hyperlipidemia (P<.001), and coronary artery disease (P<.001), Rutherford 5 or 6 lesions (P<.001), as well as more lesions treated (P<.001), more vessels treated (P<.001), and more below-the-knee lesions (P<.001). The renal disease and non-renal disease groups had similar composite procedural complication rates (21.3% vs. 22.4%; P=.46), dissection (11.1% vs. 11.5%; P=.83), perforation (0.6% vs. 0.8%; P=.55), slow flow (5.0% vs. 4.2%; P=.19), spasm (6.7% vs. 6.2%; P=.40), embolism (1.7% vs. 2.6%; P=.12), and thrombus formation (1.4% vs. 1.0%; P=.56). The renal disease group had a trend toward decreased vessel closure (1.1% vs. 1.6%; P=.08). Plaque modification with orbital atherectomy resulted in similar low rates of procedural complications in the renal disease group compared with the non-renal disease group despite more unfavorable baseline clinical and lesion characteristics in the renal disease group.

  13. Combined Directional Atherectomy and Drug-Eluting Balloon Angioplasty for Isolated Popliteal Artery Lesions in Patients With Peripheral Artery Disease.

    PubMed

    Stavroulakis, Konstantinos; Bisdas, Theodosios; Torsello, Giovanni; Stachmann, Arne; Schwindt, Arne

    2015-12-01

    To evaluate the midterm results of combined directional atherectomy (DA) and drug-eluting balloon (DEB) angioplasty for atherosclerotic lesions of the popliteal artery. In a single-arm, prospective study, 21 patients (mean age 63±16 years; 16 men) with isolated popliteal artery lesions were enrolled and underwent treatment with combined DA and DEB angioplasty under filter protection between October 2009 and February 2014. The majority (18, 86%) presented with lifestyle-limiting intermittent claudication and 3 with critical limb ischemia. Fifteen (71%) target sites were de novo lesions; 4 were occlusions. The main outcome was primary patency; secondary outcomes were technical success, secondary patency, and early and midterm morbidity and mortality. The TurboHawk atherectomy device was used in 15 (71%) patients and the SilverHawk peripheral plaque excision system in the remaining 6 patients. The In.Pact Admiral/Pacific DEB was used in the majority of cases (15, 71%). The technical success rate was 90% (n=19). One flow-limiting dissection was treated with bailout stenting. Complications included a perforation of the popliteal artery and 2 puncture site hematomas; there was no distal embolic event. The mean follow-up was 18±12 months. Two restenoses were retreated successfully. Kaplan-Meier estimates of primary patency at 12 and 18 months were 95% and 90%, respectively; the secondary patency was 100%. One (5%) patient died in follow-up. None of the patients had an amputation. In this prospective single-arm study, the combined therapy of DA and DEB angioplasty for popliteal artery lesions showed promising midterm performance. The combination of DA and DEB may, in highly selected patients, overcome the challenges presented by the mobility of the knee joint. © The Author(s) 2015.

  14. Long-term safety and performance of the orbital atherectomy system for treating calcified coronary artery lesions: 5-Year follow-up in the ORBIT I trial.

    PubMed

    Bhatt, Parloop; Parikh, Parth; Patel, Apurva; Chag, Milan; Chandarana, Anish; Parikh, Roosha; Parikh, Keyur

    2015-06-01

    The ORBIT I trial, a first-in-man study, was conducted to evaluate the safety and performance of the orbital atherectomy system (OAS) in treating de novo calcified coronary lesions. Fifty patients were enrolled between May and July 2008 based on several criteria, and were treated with the OAS followed by stent placement. The safety and performance of the OAS were evaluated by procedural success, device success, and overall major adverse cardiovascular event (MACE) rates, including cardiac death, myocardial infarction (MI) and need for target lesion revascularization (TLR). Our institution enrolled and treated 33 of the 50 patients and continued follow-up for 5 years. Average age was 54 years and 91% were males. Mean lesion length was 15.9 mm. Device success was 100%, and average number of orbital atherectomy devices (OAD) used per patient was 1.3. Stents were placed directly after OAS in 31/32 patients (96.9%). All stents (average stent per lesion 1.1) were successfully deployed with 0.3% residual stenosis. The overall cumulative MACE rate was 6.1% in-hospital, 9.1% at 30 days, 12.1% at 6 months, 15.2% at 2 years, 18.2% at 3 years and 21.2% at 5 years (4 total cardiac deaths). None of the patients had Q-wave MIs. Angiographic complications were observed in 5 patients. No flow/slow flow due to distal embolization was observed. The ORBIT I trial suggests that OAS treatment continues to offer a safe and effective method to change compliance of calcified coronary lesions to facilitate optimal stent placement in these difficult-to-treat patients. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  15. Biological effect of orbital atherectomy and adjunctive paclitaxel-coated balloon therapy on vascular healing and drug retention: early experimental insights into the familial hypercholesterolaemic swine model of femoral artery stenosis.

    PubMed

    Tellez, Armando; Dattilo, Raymond; Mustapha, Jihad A; Gongora, Carlos A; Hyon, Chelsea M; Palmieri, Taylor; Rousselle, Serge; Kaluza, Greg L; Granada, Juan F

    2014-12-01

    The efficacy of paclitaxel-coated balloons (PCB) for the treatment of superficial femoral artery (SFA) disease has been demonstrated in the clinical setting. Due to the high frequency of arterial calcification found in this vascular territory, the adjunctive use of atherectomy plus PCB has been proposed. In this study, we aimed to evaluate the biological effect on vascular healing and drug retention of this combination approach in the familial hypercholesterolaemic swine (FHS) model of femoral artery stenosis. Eleven femoral arteries (six superficial and five profunda arteries) were included. Vessels were injured (x2) over a 28-day period and all animals were maintained on a high cholesterol diet for 60 days following initial injury. Vessels were randomised to PCB (n=5) or orbital atherectomy system (OAS) plus PCB (n=6). At 28 days following therapy, vessels were followed with angiography, intravascular ultrasound (IVUS) and optical coherence tomography (OCT). Vessels were harvested for histological and pharmacokinetic analysis. Angiographic findings were comparable at termination between both groups. The OCT findings were comparable at termination. There were no differences in the vascular healing profile between both groups. The paclitaxel levels at termination were comparable between both groups (PCB=5.16 vs. OAS+PCB=3.03 ng/mg). In the experimental setting, the combination of OAS+PCB appears to be safe by demonstrating a vascular healing profile and drug tissue levels comparable to PCB only. The vascular effect of PCB may be enhanced by the use of OAS by decreasing plaque burden and cholesterol crystals.

  16. Endovascular Therapy of the Superficial Femoral Artery Via a Stand-Alone Transradial Access: A Single-Center Experience.

    PubMed

    Hanna, Elias B; Ababneh, Bashar A; Amin, Amit N

    2018-02-01

    We describe our experience in transradial recanalization of the superficial femoral artery (SFA), and we provide a stepwise approach accounting for the patient's height and optimizing the yield of currently available devices. Fifteen patients with simple SFA disease, including 4 patients with total SFA occlusions <15 cm, were selected for stand-alone transradial recanalization. A 6F, 125-cm multipurpose guiding catheter was used to cannulate the limb of interest and support device delivery. The procedure was successful in all patients and consisted of balloon angioplasty (using 0.014″, 200-cm shaft monorail balloons) in all patients, and orbital atherectomy in 6 patients. We illustrate the steps and challenges of the transradial approach, namely the limited support in complex disease and the limited reach of current equipment. In patients with simple SFA disease, transradial recanalization appears feasible and safe but currently limited to balloon angioplasty ± orbital atherectomy. Proximal SFA stenting may be feasible in patients <160 cm in height.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amano, Yasuo; Gemma, Kazuhito; Kawamata, Hiroshi

    Fat-suppressed, three-dimensional magnetic resonance angiography (3D MRA) was performed on nine patients with 11 iliac artery stenoses following atherectomy or stent placement. The MRA accurately depicted continued patency, restenosis, or aneurysm formation when compared with immediate posttreatment conventional arteriography. Therefore MRA is accurate and can be used independently for clinical decision making.

  18. Thermally activated rotational disorder in CaMoO 4 nanocrystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Culver, Sean P.; Brutchey, Richard L.

    2016-04-12

    In this study, a dual-space approach, combining Rietveld and pair distribution function (PDF) analyses, has been applied to temperature-dependent synchrotron X-ray total scattering data collected on vapor diffusion sol–gel derived CaMoO 4 nanocrystals. A sharp transition in Ca–O bond distances in the range of 151–163 K was identified by PDF analysis, which is attributed to the thermal activation of rotational disorder associated with the rigid MoO 4 tetrahedra.

  19. On mechanisms separating stars into normal and chemically peculiar

    NASA Astrophysics Data System (ADS)

    Glagolevskij, Yu. V.

    2017-10-01

    The paper argues in favor of the assumption that magnetic and non-magnetic protostars, from which CP stars were formed, are the objects that had rotation velocities of the parent cloud V smaller than a critical value V c . At V greater than the critical value, differential rotation emerges in the collapsing protostellar cloud, which twists magnetic lines of force into an' invisible' toroidal shape and disturbs the stability of the atmosphere. In magnetic protostars, the loss of angular momentum is due to magnetic braking, while in metallic protostars, the loss of rotation momentum occurs due to tidal interactions with a close component. HgMn stars are most likely not affected by some braking mechanism, but originated from the slowest protostellar rotators. The boundary of V c where the differential rotation occurs is not sharp. The slower the protostar rotates, the greater the probability of suppressing the differential rotation and the more likely the possibility of CP star birth.

  20. Sharp magnetic structures from dynamos with density stratification

    NASA Astrophysics Data System (ADS)

    Jabbari, Sarah; Brandenburg, Axel; Kleeorin, Nathan; Rogachevskii, Igor

    2017-05-01

    Recent direct numerical simulations (DNS) of large-scale turbulent dynamos in strongly stratified layers have resulted in surprisingly sharp bipolar structures at the surface. Here, we present new DNS of helically and non-helically forced turbulence with and without rotation and compare with corresponding mean-field simulations (MFS) to show that these structures are a generic outcome of a broader class of dynamos in density-stratified layers. The MFS agree qualitatively with the DNS, but the period of oscillations tends to be longer in the DNS. In both DNS and MFS, the sharp structures are produced by converging flows at the surface and might be driven in non-linear stage of evolution by the Lorentz force associated with the large-scale dynamo-driven magnetic field if the dynamo number is at least 2.5 times supercritical.

  1. The feasibility of transradial laser atherectomy for chronic total occlusion using the 5 Fr sheath system.

    PubMed

    Sherif, Khaled; Yaqub, Yasir; Suarez, Jose A

    2016-05-01

    We present a case of chronic total occlusion (CTO) approached with LASER endovascular intervention by radial artery approach using a 5 French sheath. A 57-year-old man presented to our hospital having had retrosternal chest pain for two days. Physical examination was normal at the time of presentation. The laboratory tests were within normal limits, including cardiac enzymes except the lipid panel which showed hypertriglyceridemia. The patient underwent a myocardial perfusion scintigraphy stress test that revealed inferior wall ischemia, with normal left ventricular ejection fraction. A 5-French vascular sheath was placed in the right radial artery. Selective coronary artery angiography was performed, which showed right coronary artery (RCA) CTO. A 5-French JR4 guide catheter successfully engaged the RCA and Laser angioplasty was performed across the CTO into the RCA. A marked improvement of flow was evident thereafter. To best of our knowledge this is the first case report showing the feasibility of laser atherectomy using the 5 French sheath system in a coronary arterial CTO. Copyright © 2016 by Academy of Sciences and Arts of Bosnia and Herzegovina.

  2. Intraluminal laser atherectomy with ultrasound and electromagnetic guidance

    NASA Astrophysics Data System (ADS)

    Gregory, Kenton W.; Aretz, H. Thomas; Martinelli, Michael A.; LeDet, Earl G.; Hatch, G. F.; Gregg, Richard E.; Sedlacek, Tomas; Haase, Wayne C.

    1991-05-01

    The MagellanTM coronary laser atherectomy system is described. It uses high- resolution ultrasound imaging and electromagnetic sensing to provide real-time guidance and control of laser therapy in the coronary arteries. The system consists of a flexible catheter, an electromagnetic navigation antenna, a sensor signal processor and a computer for image processing and display. The small, flexible catheter combines an ultrasound transducer and laser delivery optics, aimed at the artery wall, and an electromagnetic receiving sensor. An extra-corporeal electromagnetic transmit antenna, in combination with catheter sensors, locates the position of the ultrasound and laser beams in the artery. Navigation and ultrasound data are processed electronically to produce real-time, transverse, and axial cross-section images of the artery wall at selected locations. By exploiting the ability of ultrasound to image beneath the surface of artery walls, it is possible to identify candidate treatment sites and perform safe radial laser debulking of atherosclerotic plaque with reduced danger of perforation. The utility of the system in plaque identification and ablation is demonstrated with imaging and experimental results.

  3. How automated access verification can help organizations demonstrate HIPAA compliance: A case study.

    PubMed

    Hill, Linda

    2006-01-01

    This case study of Sharp HealthCare takes an in depth look at how the organization has embedded security policies into its business process and automated workflow to ensure users are granted only the IT access that is necessary for them to perform their jobs and to ensure patient privacy Some of the most pressing audit and compliance concerns in healthcare organizations today revolve around the need to constantly review and give an account for users' IT access. The need for this at Sharp is exacerbated because of the high rate of change within the organization and the large percentage of non-employee staff such as traveling nurses moving throughout hospital departments on their rotations. By implementing a software solution to verify the accuracy of user access rights or automatically initiate appropriate corrective actions, Sharp is now able to extend the responsibility and accountability for compliance to the most appropriate resources.

  4. Case study of the operational usefulness of the Sharp Workstation in forecasting a mesocyclone-induced cold sector Tornado event in California. Technical memo

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Monteverdi, J.P.

    1993-03-01

    An illustration of the operational usefulness of the SHARP Workstation in providing supplementary guidance to forecasters in a situation in which two tornadoes occurred in California's Sacramento Valley is presented. Use of the SHARP Workstation in analyzing the initial hodograph and in producing a bogus afternoon sounding and hodograph for the Sacramento Valley indicated that buoyancy and shear were in the correct range for moderate to strong mesocyclone-induced tornadoes. Conventional wisdom would have suggested that weak funnel clouds and small hail were the chief threats in the weather pattern. However, forecasters, aware of the role of shear in inducing stormmore » rotation and of the potential for the weather pattern to be associated with favorable buoyancy and shear parameters in certain regions of California, would have been alert to the possibility of damaging and potentially life-threatening tornadoes.« less

  5. Differences in patient selection and outcomes between SilverHawk atherectomy and laser ablation in the treatment of femoropopliteal in-stent restenosis: a retrospective analysis from a single center.

    PubMed

    Shammas, Nicolas W; Shammas, Gail A; Jerin, Michael

    2013-12-01

    To analyze differences in the application and outcomes of SilverHawk atherectomy (SH) and excimer laser ablation (ELA) in the treatment of femoropopliteal in-stent restenosis (ISR) in an unselected cohort of patients treated at a single center. Between January 2005 and June 2010, 81 consecutive patients (46 men; mean age 69.1 years, range 43-86) underwent directional atherectomy (41 SH, 40 ELA) for femoropopliteal ISR lesions. Data were reviewed retrospectively on procedural outcomes, major adverse events, and 1-year target lesion revascularization (TLR) obtained from medical records and supplemented with telephone calls. The primary endpoint was symptom-driven TLR at 1 year; secondary endpoints were death and amputation. ELA was utilized more frequently than SH in longer lesions (210.4±104 vs. 126.2±79.3 mm, respectively; p=0.001), subacute presentation (55% vs. 14.6%, p=0.001), TASC D lesions (47.5% vs. 12.2%), and in patients with more angiographic thrombus (42.5% vs. 4.9%, p=0.001). Final angiographic success (<30% residual narrowing post final treatment) was similar between ELA and SH (92.5% vs. 100%, respectively, p=0.12). Bailout stenting was significantly higher with ELA vs. SH (50.0% vs. 24.4%, p=0.022). At 1 year, TLR had occurred in 48.7% of the ELA patients vs. 31.7% of the SH cases (p=0.171). Regression analysis confirmed that SH was a predictor of TLR at 1 year (hazard ratio 2.679, 95% CI 1.015 to 7.073, p=0.047). Both SH and ELA continue to have a high TLR rate in treating ISR of the femoral and popliteal arteries. A higher rate of delayed failure is seen with SH and an earlier, steeper loss of TLR-free survival is seen with ELA.

  6. Meta-analysis of randomized trials of percutaneous transluminal coronary angioplasty versus atherectomy, cutting balloon atherotomy, or laser angioplasty.

    PubMed

    Bittl, John A; Chew, Derek P; Topol, Eric J; Kong, David F; Califf, Robert M

    2004-03-17

    We conducted a systematic overview (meta-analysis) of randomized trials of balloon angioplasty versus coronary atherectomy, laser angioplasty, or cutting balloon atherotomy to evaluate the effects of plaque modification during percutaneous coronary intervention. Several mechanical approaches have been developed that ablate or section atheromatous plaque during percutaneous coronary interventions to optimize acute results, minimize intimal injury, and reduce complications and restenosis. Sixteen trials (9,222 patients) constitute the randomized controlled experience with atherectomy, laser, or atherotomy versus balloon angioplasty with or without coronary stenting. Each trial tested the hypothesis that ablative therapy would result in better clinical or angiographic results than balloon dilation alone. Short-term death rates (<31 days) were not improved by the use of ablative procedures (0.3% vs. 0.4%, odds ratio [OR] 0.94 [95% confidence interval 0.46 to 1.92]), but periprocedural myocardial infarctions (4.4% vs. 2.5%, OR 1.83 [95% CI 1.43 to 2.34]) and major adverse cardiac events (5.1% vs. 3.3%, OR 1.54 [95% CI 1.25 to 1.89]) were increased. Angiographic restenosis rates (6,958 patients) were not improved with the ablative devices (38.9% vs. 37.4%, OR 1.06 [95% CI 0.97 to 1.17]). No reduction in revascularization rates (25.2% vs. 24.5%, OR 1.04 [95% CI 0.94 to 1.14]) or cumulative adverse cardiac events rates up to one year after treatment were seen with ablative devices (27.8% vs. 26.1%, OR 1.09 [95% CI 0.99 to 1.20]). The combined experience from randomized trials suggests that ablative devices failed to achieve predefined clinical and angiographic outcomes. This meta-analysis does not support the hypothesis that routine ablation or sectioning of atheromatous tissue is beneficial during percutaneous coronary interventions.

  7. On sharp vorticity gradients in elongating baroclinic eddies and their stabilization with a solid-body rotation

    NASA Astrophysics Data System (ADS)

    Sutyrin, Georgi G.

    2016-06-01

    Wide compensated vortices are not able to remain circular in idealized two-layer models unless the ocean depth is assumed to be unrealistically large. Small perturbations on both cyclonic and anticyclonic eddies grow slower if a middle layer with uniform potential vorticity (PV) is added, owing to a weakening of the vertical coupling between the upper and lower layers and a reduction of the PV gradient in the deep layer. Numerical simulations show that the nonlinear development of the most unstable elliptical mode causes self-elongation of the upper vortex core and splitting of the deep PV anomaly into two corotating parts. The emerging tripolar flow pattern in the lower layer results in self-intensification of the fluid rotation in the water column around the vortex center. Further vortex evolution depends on the model parameters and initial conditions, which limits predictability owing to multiple equilibrium attractors existing in the dynamical system. The vortex core strips thin filaments, which roll up into submesoscale vortices to result in substantial mixing at the vortex periphery. Stirring and damping of vorticity by bottom friction are found to be essential for subsequent vortex stabilization. The development of sharp PV gradients leads to nearly solid-body rotation inside the vortex core and formation of transport barriers at the vortex periphery. These processes have important implications for understanding the longevity of real-ocean eddies.

  8. An ignition key for atomic-scale engines

    NASA Astrophysics Data System (ADS)

    Dundas, Daniel; Cunningham, Brian; Buchanan, Claire; Terasawa, Asako; Paxton, Anthony T.; Todorov, Tchavdar N.

    2012-10-01

    A current-carrying resonant nanoscale device, simulated by non-adiabatic molecular dynamics, exhibits sharp activation of non-conservative current-induced forces with bias. The result, above the critical bias, is generalized rotational atomic motion with a large gain in kinetic energy. The activation exploits sharp features in the electronic structure, and constitutes, in effect, an ignition key for atomic-scale motors. A controlling factor for the effect is the non-equilibrium dynamical response matrix for small-amplitude atomic motion under current. This matrix can be found from the steady-state electronic structure by a simpler static calculation, providing a way to detect the likely appearance, or otherwise, of non-conservative dynamics, in advance of real-time modelling.

  9. Imaging the dynamics of free-electron Landau states

    PubMed Central

    Schattschneider, P.; Schachinger, Th.; Stöger-Pollach, M.; Löffler, S.; Steiger-Thirsfeld, A.; Bliokh, K. Y.; Nori, Franco

    2014-01-01

    Landau levels and states of electrons in a magnetic field are fundamental quantum entities underlying the quantum Hall and related effects in condensed matter physics. However, the real-space properties and observation of Landau wave functions remain elusive. Here we report the real-space observation of Landau states and the internal rotational dynamics of free electrons. States with different quantum numbers are produced using nanometre-sized electron vortex beams, with a radius chosen to match the waist of the Landau states, in a quasi-uniform magnetic field. Scanning the beams along the propagation direction, we reconstruct the rotational dynamics of the Landau wave functions with angular frequency ~100 GHz. We observe that Landau modes with different azimuthal quantum numbers belong to three classes, which are characterized by rotations with zero, Larmor and cyclotron frequencies, respectively. This is in sharp contrast to the uniform cyclotron rotation of classical electrons, and in perfect agreement with recent theoretical predictions. PMID:25105563

  10. Shaping effects on toroidal magnetohydrodynamic modes in the presence of plasma and wall resistivity

    NASA Astrophysics Data System (ADS)

    Rhodes, Dov J.; Cole, A. J.; Brennan, D. P.; Finn, J. M.; Li, M.; Fitzpatrick, R.; Mauel, M. E.; Navratil, G. A.

    2018-01-01

    This study explores the effects of plasma shaping on magnetohydrodynamic mode stability and rotational stabilization in a tokamak, including both plasma and wall resistivity. Depending upon the plasma shape, safety factor, and distance from the wall, the β-limit for rotational stabilization is given by either the resistive-plasma ideal-wall (tearing mode) limit or the ideal-plasma resistive-wall (resistive wall mode) limit. In order to explore this broad parameter space, a sharp-boundary model is developed with a realistic geometry, resonant tearing surfaces, and a resistive wall. The β-limit achievable in the presence of stabilization by rigid plasma rotation, or by an equivalent feedback control with imaginary normal-field gain, is shown to peak at specific values of elongation and triangularity. It is shown that the optimal shaping with rotation typically coincides with transitions between tearing-dominated and wall-dominated mode behavior.

  11. Surgical treatment for Ellis type 3 coronary perforation during percutaneous catheter intervention.

    PubMed

    Totsugawa, Toshinori; Kuinose, Masahiko; Yoshitaka, Hidenori; Katayama, Keijiro; Tsushima, Yoshimasa; Ishida, Atsuhisa; Chikazawa, Genta; Hiraoka, Arudo

    2012-01-01

    Coronary perforation (CP) is a rare, but sometimes lethal, complication of percutaneous catheter intervention (PCI). We reviewed surgically-treated cases of type 3 CP during PCI. From 2007 to 2010, 5 patients underwent surgical repair for type 3 CP (3 men, 2 women; mean age, 74 years). The mean number of diseased coronary branches was 2.6 and the mean SYNTAX score was 45. The target lesions were the left anterior descending artery in 4 cases and the right coronary artery in 1 case. Types of American Heart Association/American College of Cardiology classification were type B2 in only one case and type C in 4 cases. The causes of perforation were balloon inflation in 4 patients and rotational atherectomy in 1 patient. The in-hospital mortality rate was 20%. In the cases of CP associated with balloon inflation, coronary lacerations were so severe that re-bleeding occurred even if the covered stent could temporarily achieve hemostasis, and percutaneous cardiopulmonary support and emergency surgery were required. CP induced by balloon inflation tends to result in a serious condition compared with rotablator-induced CP. Surgery should be immediately performed even after covered stent implantation if there is any possibility of re-bleeding in the case of balloon-induced type 3 CP.

  12. Intraluminal ultrasound guidance of transverse laser coronary atherectomy

    NASA Astrophysics Data System (ADS)

    Aretz, H. Thomas; Martinelli, Michael A.; LeDet, Earl G.; Sedlacek, Tomas; Hatch, G. F.; Gregg, Richard E.

    1990-07-01

    A coronary laser atherectomy system combining laser delivery and ultrasonic imaging capability is described. The system is being developed by Intra-Sonix, Inc. to treat severe stenoses. The imaging system provides the clinician with the guidance needed to remove substantial plaque without perforation. The ultrasound transducers and laser optics are mounted in a small (less than 4 F), flexible catheter, that is deliverable over a standard guidewire (0.016 inch). The laser and ultrasound beams are directed at the artery wall to permit debulking of lesions and ultrasonic depth profiling of the tissue structure throughout the thickness of the artery. This allows the physician to determine the level of therapy to be applied and to monitor the plaque removal as the therapy progresses. The precise location of the ultrasound and laser beams in the artery is determined by a navigation system. Navigation data are processed electronically in conjunction with ultrasound data to produce real-time cross-sectional and longitudinal images of the artery wall at selected locations, which are updated as the catheter progresses through the vessel lumen. Results of in vitro tests on human atherosclerotic arteries and early in vivo experiments in a canine-human xenograft model showing image construction and radial laser delivery are discussed.

  13. Titan's ion exosphere observed from Voyager 1

    NASA Technical Reports Server (NTRS)

    Hartle, R. E.; Sittler, E. C., Jr.; Ogilvie, K. W.; Scudder, J. D.; Lazarus, A. J.; Atreya, S. K.

    1982-01-01

    The plasma wake surrounding Titan in Saturn's rotating magnetosphere is characterized by a plasma which is denser and cooler than the surrounding subsonic magnetospheric plasma, and which is produced by the deflection of magnetospheric plasma around Titan and the addition of exospheric ions picked up by the rotating magnetosphere. A resemblance to the interaction between the solar wind and Venus is shown for the case of ion pickup in the ion exosphere outside Titan's magnetic tail and ion flow within the boundaries of the tail as Saturn's rotating magnetosphere interacts with Titan. The boundary of the tail is indicated by a sharp reduction in the flux of high-energy electrons, which are removed by inelastic scattering with the atmosphere and centrifugal drift produced when the electrons traverse the magnetic field draped around Saturn.

  14. Acupuncture sensation during ultrasound guided acupuncture needling

    PubMed Central

    Park, Jongbae J.; Akazawa, Margeaux; Ahn, Jaeki; Beckman-Harned, Selena; Lin, Feng-Chang; Lee, Kwangjae; Fine, Jason; Davis, Robert T; Langevin, Helene

    2014-01-01

    Background Although acupuncture sensation (also known as de qi) is a cornerstone of traditional acupuncture therapy, most research has accepted the traditional method of defining acupuncture sensation only through subjective patient reports rather than on any quantifiable physiological basis. Purpose To preliminarily investigate the frequency of key sensations experienced while needling to specific, quantifiable tissue levels (TLs) guided by ultrasound (US) imaging. Methods Five participants received needling at two acupuncture points and two control points at four TLs. US scans were used to determine when each TL was reached. Each volunteer completed 32 sets of modified Southampton Needle Sensation Questionnaires. Part one of the study tested sensations experienced at each TL and part two compared the effect of oscillation alone versus oscillation + rotation. Results In all volunteers, the frequency of pricking, sharp sensations was significantly greater in shallower TLs than deeper (p=0.007); the frequency of sensations described as deep, dull and heavy, as spreading, and as electric shocks was significantly greater in deeper TLs than shallower (p=0.002). Sensations experienced did not significantly differ between real and control points within each of three TLs (p>0.05) except TL 4 (p=0.006). The introduction of needle rotation significantly increased deep, dull, heavy sensations, but not pricking and sharp sensations; within each level, the spectrum of sensation experienced during both oscillation + rotation and oscillation alone did not significantly differ between acupuncture and control points. Conclusion The preliminary study indicates a strong connection between acupuncture sensation and both tissue depth and needle rotation. Furthermore, the new methodology has been proven feasible. A further study with an objective measurement is warranted. PMID:21642648

  15. Orbital Atherectomy for Treating De Novo Severely Calcified Coronary Narrowing (1-Year Results from the Pivotal ORBIT II Trial).

    PubMed

    Généreux, Philippe; Lee, Arthur C; Kim, Christopher Y; Lee, Michael; Shlofmitz, Richard; Moses, Jeffrey W; Stone, Gregg W; Chambers, Jeff W

    2015-06-15

    Percutaneous coronary intervention of severely calcified lesions has historically been associated with major adverse cardiac event (MACE) rates as high as 30%. In the ORBIT II (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) trial, treatment of de novo severely calcified lesions with the Diamondback 360° Coronary Orbital Atherectomy System (OAS) resulted in low rates of procedural and 30-day adverse ischemic events. The long-term results from this trial have not been reported. We sought to determine the 1-year outcomes after orbital atherectomy of severely calcified coronary lesions. ORBIT II was a single-arm trial enrolling 443 subjects at 49 US sites with severely calcified lesions usually excluded from randomized trials. OAS utilizes a centrifugal differential sanding mechanism of action for plaque modification prior to stent implantation. After OAS drug-eluting stents were implanted in 88.2% of the patients. The primary safety end point was 30-day MACE, the composite of cardiac death, myocardial infarction, or target vessel revascularization [TVR]. The present analysis reports the 1-year follow-up results from ORBIT II. One-year data were available in 433 of 443 patients (97.7%), with median follow-up time of 16.7 months. The 1-year MACE rate was 16.4%, including cardiac death (3.0%), myocardial infarction (9.7%), and target vessel revascularization (5.9%). The 1-year target lesion revascularization rate was 4.7%, and stent thrombosis occurred in 1 patient (0.2%). Independent predictors of 1-year MACE and target vessel revascularization were diameter stenosis at baseline and the use of bare-metal stents. In patients with severely calcified lesions who underwent percutaneous coronary intervention, the use of OAS was associated with low rates of 1-year adverse ischemic events compared with historical controls. This finding has important clinical implications for the selection of optimum treatment strategies for patients with severely calcified lesions. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Tyrosine phosphorylation of platelet derived growth factor β receptors in coronary artery lesions: implications for vascular remodelling after directional coronary atherectomy and unstable angina pectoris

    PubMed Central

    Abe, J; Deguchi, J; Takuwa, Y; Hara, K; Ikari, Y; Tamura, T; Ohno, M; Kurokawa, K

    1998-01-01

    Background—Growth factors such as platelet derived growth factor (PDGF) have been postulated to be important mediators of neointimal proliferation observed in atherosclerotic plaques and restenotic lesions following coronary interventions. Binding of PDGF to its receptor results in intrinsic receptor tyrosine kinase activation and subsequent cellular migration, proliferation, and vascular contraction.
Aims—To investigate whether the concentration of PDGF β receptor tyrosine phosphorylation obtained from directional coronary atherectomy (DCA) samples correlate with atherosclerotic plaque burden, the ability of diseased vessels to remodel, coronary risk factors, and clinical events.
Methods—DCA samples from 59 patients and 15 non-atherosclerotic left internal thoracic arteries (LITA) were analysed for PDGF β receptor tyrosine phosphorylation content by receptor immunoprecipitation and antiphosphotyrosine western blot. The amount of PDGF β receptor phosphorylation was analysed in relation to angiographic follow up data and clinical variables.
Results—PDGF β receptor tyrosine phosphorylation in the 59 DCA samples was greater than in the 15 non-atherosclerotic LITA (mean (SD) 0.84 (0.67) v 0.17 (0.08) over a control standard, p < 0.0001). As evaluated by stepwise regression analysis, incorporation of both PDGF β receptor tyrosine phosphorylation and immediate gain correlated strongly (adjusted r2 = 0.579) with late loss, although PDGF β receptor tyramine phosphorylation alone correlated poorly with late loss. Multivariate regression analysis of coronary risk factors and clinical events revealed unstable angina as the most significant correlate of PDGF β receptor tyrosine phosphorylation (F value 20.009, p < 0.0001).
Conclusions—PDGF β receptor tyrosine phosphorylation in atherosclerotic lesions is increased compared with non-atherosclerotic arterial tissues. The association of PDGF β receptor tyrosine phosphorylation with immediate gain strongly correlates with vascular remodelling. PDGF β receptor tyrosine phosphorylation correlates with unstable angina pectoris.

 Keywords: PDGF receptors;  atherosclerosis;  directional coronary atherectomy;  restenosis PMID:9616351

  17. Cost-effectiveness analysis of orbital atherectomy plus balloon angioplasty vs balloon angioplasty alone in subjects with calcified femoropopliteal lesions

    PubMed Central

    Weinstock, Barry; Dattilo, Raymond; Diage, Tiffini

    2014-01-01

    Introduction As cost considerations become increasingly critical when selecting optimal endovascular treatment strategies, a cost-benefit analysis was conducted comparing the Diamondback 360°® Orbital Atherectomy System (OAS) (Cardiovascular Systems, Inc., St Paul, MN, USA) and balloon angioplasty (BA) vs BA alone for treatment of calcified femoropopliteal lesions. Patients and methods The clinical outcomes from COMPLIANCE 360°, a prospective, multicenter, randomized study comparing OAS+BA vs BA alone for treatment of calcified femoropopliteal lesions, were correlated with cost data and previously published quality of life data. Site of service, hospital charges, and associated medical resource utilization were obtained from Uniform Billing statements for index treatments and associated revascularizations out to 1 year. Hospital costs were estimated using hospital-specific, procedure-specific cost-to-charge ratios. Length of stay and procedural data were collected from participating study sites. Results Twenty-five subjects with 38 lesions and 25 subjects with 27 lesions were randomized to the OAS+BA and BA-alone groups, respectively. Mean hospital charges (US$51,755 vs US$39,922) and estimated hospital costs (US$15,100 vs US$11,016) were higher for OAS+BA compared with BA alone (not statistically significant). Stent utilization was statistically significantly higher with BA-alone treatment for all subjects (1.1 vs 0.1, P=0.001) and in the subset of subjects with one lesion (1.0 vs 0.1, P<0.00001). There was a significant difference in cost for single-lesion versus multiple-lesion treatment. Using costs and quality-adjusted life years (QALYs) for the single-lesion cohort, the 1-year incremental cost of OAS+BA vs BA alone was US$549, and incremental QALY was 0.16. This results in an incremental cost-effectiveness ratio of US$3,441, well below the US$50,000 threshold. Conclusion One-year index procedure cost and cost-effectiveness were comparable for OAS+BA vs BA alone. This study provides compelling cost-effectiveness data for using atherectomy for treatment of calcified femoropopliteal lesions, a longstanding challenge for peripheral artery disease interventionalists. PMID:24672251

  18. Cost-effectiveness analysis of orbital atherectomy plus balloon angioplasty vs balloon angioplasty alone in subjects with calcified femoropopliteal lesions.

    PubMed

    Weinstock, Barry; Dattilo, Raymond; Diage, Tiffini

    2014-01-01

    As cost considerations become increasingly critical when selecting optimal endovascular treatment strategies, a cost-benefit analysis was conducted comparing the Diamondback 360°® Orbital Atherectomy System (OAS) (Cardiovascular Systems, Inc., St Paul, MN, USA) and balloon angioplasty (BA) vs BA alone for treatment of calcified femoropopliteal lesions. The clinical outcomes from COMPLIANCE 360°, a prospective, multicenter, randomized study comparing OAS+BA vs BA alone for treatment of calcified femoropopliteal lesions, were correlated with cost data and previously published quality of life data. Site of service, hospital charges, and associated medical resource utilization were obtained from Uniform Billing statements for index treatments and associated revascularizations out to 1 year. Hospital costs were estimated using hospital-specific, procedure-specific cost-to-charge ratios. Length of stay and procedural data were collected from participating study sites. Twenty-five subjects with 38 lesions and 25 subjects with 27 lesions were randomized to the OAS+BA and BA-alone groups, respectively. Mean hospital charges (US$51,755 vs US$39,922) and estimated hospital costs (US$15,100 vs US$11,016) were higher for OAS+BA compared with BA alone (not statistically significant). Stent utilization was statistically significantly higher with BA-alone treatment for all subjects (1.1 vs 0.1, P=0.001) and in the subset of subjects with one lesion (1.0 vs 0.1, P<0.00001). There was a significant difference in cost for single-lesion versus multiple-lesion treatment. Using costs and quality-adjusted life years (QALYs) for the single-lesion cohort, the 1-year incremental cost of OAS+BA vs BA alone was US$549, and incremental QALY was 0.16. This results in an incremental cost-effectiveness ratio of US$3,441, well below the US$50,000 threshold. One-year index procedure cost and cost-effectiveness were comparable for OAS+BA vs BA alone. This study provides compelling cost-effectiveness data for using atherectomy for treatment of calcified femoropopliteal lesions, a longstanding challenge for peripheral artery disease interventionalists.

  19. Relativistic Dynamos in Magnetospheres of Rotating Compact Objects

    NASA Astrophysics Data System (ADS)

    Tomimatsu, Akira

    2000-01-01

    The kinematic evolution of axisymmetric magnetic fields in rotating magnetospheres of relativistic compact objects is analytically studied, based on relativistic Ohm's law in stationary axisymmetric geometry. By neglecting the poloidal flows of plasma in simplified magnetospheric models, we discuss a self-excited dynamo due to the frame-dragging effect (originally pointed out by Khanna & Camenzind) and propose alternative processes to generate axisymmetric magnetic fields against ohmic dissipation. The first process (which may be called ``induced excitation'') is caused by the help of a background uniform magnetic field in addition to the dragging of inertial frames. It is shown that excited multipolar components of poloidal and azimuthal fields are sustained as stationary modes, and outgoing Poynting flux converges toward the rotation axis. The second process is a self-excited dynamo through azimuthal convection current, which is found to be effective if plasma rotation becomes highly relativistic with a sharp gradient in the angular velocity. In this case, no frame-dragging effect is needed, and the coupling between charge separation and plasma rotation becomes important. We discuss briefly the results in relation to active phenomena in the relativistic magnetospheres.

  20. IUE observations of rapidly rotating low-mass stars in young clusters - The relation between chromospheric activity and rotation

    NASA Technical Reports Server (NTRS)

    Simon, Theodore

    1990-01-01

    If the rapid spindown of low-mass stars immediately following their arrival on the ZAMS results from magnetic braking by coronal winds, an equally sharp decline in their chromospheric emission may be expected. To search for evidence of this effect, the IUE spacecraft was used to observe the chromospheric Mg II emission lines of G-M dwarfs in the nearby IC 2391, Alpha Persei, Pleiades, and Hyades clusters. Similar observations were made of a group of X-ray-selected 'naked' T Tauri stars in Taurus-Auriga. The existence of a decline in activity cannot be confirmed from the resulting data. However, the strength of the chromospheric emission in the Mg II lines of the cluster stars is found to be correlated with rotation rate, being strongest for the stars with the shortest rotation periods and weakest for those with the longest periods. This provides indirect support for such an evolutionary change in activity. Chromospheric activity may thus be only an implicit function of age.

  1. Development of a lemon cutting machine.

    PubMed

    Hrishikesh Tavanandi, A; Deepak, S; Venkateshmurthy, K; Raghavarao, K S M S

    2014-12-01

    Cutting of lemon and other similar fruits is conventionally done manually by sharp knife, which is labor intensive and often un-hygienic. In the present work, a device has been designed and developed for cutting of lemon hygienically into four pieces of similar shape based on stationery cutters and rotating centralizing/locating slit plate concept. Machine has a unique knife assembly consisting of two bird wing shaped knives, joined by welding perpendicularly to a vertical knife, so that the lemon can be cut into four pieces in a single sweep. Six numbers of rotating centralizing/locating slit plates are welded on to the side plates and the plates carry a groove on its inner face, to enable the wing shaped knife to complete the horizontal cut. The rotating slit plates, having centralizing angle of 90°, are rotated by an electric geared motor. The prototype machine has capacity of over 5,000 lemons/h with a power consumption of 0.11 kW.

  2. The use of drug-coated balloons in the treatment of femoropopliteal and infrapopliteal disease.

    PubMed

    Li, Jun; Karim, Adham; Shishehbor, Mehdi

    2018-05-25

    While the field of endovascular interventions has evolved in the last decade, technological advancements have rendered drug-coated balloons (DCBs) to be the first line therapy for femoropopliteal artery disease. As the knowledge continues to advance, the application of DCB to the infrapopliteal segments and its role in the setting of plaque modification atherectomy to minimize stent utilization will be further elucidated.

  3. Atherectomy using a solid-state laser at 355 nm wavelength.

    PubMed

    Herzog, Amir; Oszkinis, Grzegorz; Planer, David; Ziaja, Krzysztof; Kruszyna, Łukasz; Stanisić, Michał Goran; Ziaja, Damian; Ishaaya, Amiel A; Kuczmik, Wacław

    2017-10-01

    Peripheral arterial disease (PAD), caused by atherosclerotic processes, is allied with an increased risk of ischemic events, limb loss, and death. Recently, the use of a solid-state laser at 355 nm within a hybrid catheter was suggested for that purpose. In this work, short nanosecond pulses of a solid-state laser at 355 nm delivered through a hybrid catheter, composed of optical fibers and a blunt mechanical blade, are used to conduct a pre-clinical study and two clinical cases. The pre-clinical study consisted of an atherosclerotic calcified cadaveric leg and a porcine in vivo trial within the iliac artery, respectively. The clinical cases include chronic total occlusions with a calcified lesion. The occluded cadaveric leg is recanalized successfully and no evidence of thermal necrosis is indicated in the histopathology analysis of the porcine study. No arterial wall damage is demonstrated on the animals' treated arteries and no significant impact on blood count and biochemistry analysis is noted in the animal trial. Successful recanalization of the occluded arteries followed by balloon angioplasty is obtained in both clinical cases. Our work constitutes a proof of concept for using a solid-state pulsed laser at 355 nm in atherectomy. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Sharp Interface Tracking in Rotating Microflows of Solvent Extraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glimm, James; Almeida, Valmor de; Jiao, Xiangmin

    2013-01-08

    The objective of this project is to develop a specialized sharp interface tracking simulation capability for predicting interaction of micron-sized drops and bubbles in rotating flows relevant to optimized design of contactor devices used in solvent extraction processes of spent nuclear fuel reprocessing. The primary outcomes of this project include the capability to resolve drops and bubbles micro-hydrodynamics in solvent extraction contactors, determining from first principles continuum fluid mechanics how micro-drops and bubbles interact with each other and the surrounding shearing fluid for realistic flows. In the near term, this effort will play a central role in providing parameters andmore » insight into the flow dynamics of models that average over coarser scales, say at the millimeter unit length. In the longer term, it will prove to be the platform to conduct full-device, detailed simulations as parallel computing power reaches the exaflop level. The team will develop an accurate simulation tool for flows containing interacting droplets and bubbles with sharp interfaces under conditions that mimic those found in realistic contactor operations. The main objective is to create an off-line simulation capability to model drop and bubble interactions in a domain representative of the averaged length scale. The technical approach is to combine robust interface tracking software, subgrid modeling, validation quality experiments, powerful computational hardware, and a team with simulation modeling, physical modeling and technology integration experience. Simulations will then fully resolve the microflow of drops and bubbles at the microsecond time scale. This approach is computationally intensive but very accurate in treating important coupled physical phenomena in the vicinity of interfaces. The method makes it possible to resolve spatial scales smaller than the typical distance between bubbles and to model some non-equilibrium thermodynamic features such as finite critical tension in cavitating liquids« less

  5. Evaluation Of Rotation Frequency Gas-Diesel Engines When Using Automatic Control System

    NASA Astrophysics Data System (ADS)

    Zhilenkov, A.; Efremov, A.

    2017-01-01

    A possibility of quality improvement of stabilization of rotation frequency of the gas-diesels used as prime mover of generator set in the multigenerator units working for abruptly variable load of large power is considered. An evaluation is made on condition of fuzzy controller use developed and described by the authors in a number of articles. An evaluation has shown that theoretically, the revolution range of gas-diesel engine may be reduced at 25-30 times at optimal settings of the controller in all the power range. The results of modeling showing a considerable quality improvement of transient processes in the investigated system at a sharp change of loading are presented in this article.

  6. Associative electron detachment - O(-) + H yields OH + e(-)

    NASA Astrophysics Data System (ADS)

    Acharya, P. K.; Kendall, R. A.; Simons, J.

    1985-10-01

    Diatomic associative electron detachment (AED) involves the ejection of an electron when a atomic anion and another atom collisionally associate to produce a neutral diatomic molecule in a vibration-rotation state labeled V-prime, J-prime. Electron ejection rate calculations are discussed, taking into account aspects of rate expressions, calculations of ingredients in rate expression, initial-condition weighting factors, and the vibration and rotation dependence of ejection rates. The results of ab initio theoretical simulations indicate that AED in O(-) + H is so slow (approximately 10,000 per s) that it is likely to be inaccessible to present experimental observation. Propensity for producing OH in high vibrational levels does occur but the propensity is not sharp.

  7. Tunable electromagnetically induced transparency in coupled three-dimensional split-ring-resonator metamaterials

    PubMed Central

    Han, Song; Cong, Longqing; Lin, Hai; Xiao, Boxun; Yang, Helin; Singh, Ranjan

    2016-01-01

    Metamaterials have recently enabled coupling induced transparency due to interference effects in coupled subwavelength resonators. In this work, we present a three dimensional (3-D) metamaterial design with six-fold rotational symmetry that shows electromagnetically induced transparency with a strong polarization dependence to the incident electromagnetic wave due to the ultra-sharp resonance line width as a result of interaction between the constituent meta-atoms. However, when the six-fold rotationally symmetric unit cell design was re-arranged into a fourfold rotational symmetry, we observed the excitation of a polarization insensitive dual-band transparency. Thus, the 3-D split-ring resonators allow new schemes to observe single and multi-band classical analogues of electromagnetically induced transparencies that has huge potential applications in slowing down light, sensing modalities, and filtering functionalities either in the passive mode or the active mode where such effects could be tuned by integrating materials with dynamic properties. PMID:26857034

  8. Flows with fractional quantum circulation in Bose-Einstein condensates induced by nontopological phase defects

    NASA Astrophysics Data System (ADS)

    Kanai, Toshiaki; Guo, Wei; Tsubota, Makoto

    2018-01-01

    It is a common view that rotational motion in a superfluid can exist only in the presence of topological defects, i.e., quantized vortices. However, in our numerical studies on the merging of two concentric Bose-Einstein condensates with axial symmetry in two-dimensional space, we observe the emergence of a spiral dark soliton when one condensate has a nonzero initial angular momentum. This spiral dark soliton enables the transfer of angular momentum between the condensates and allows the merged condensate to rotate even in the absence of quantized vortices. Our examination of the flow field around the soliton strikingly reveals that its sharp endpoint can induce flow like a vortex point but with a fraction of a quantized circulation. This interesting nontopological "phase defect" may generate broad interest since rotational motion is essential in many quantum transport processes.

  9. A Detailed Study of Sonar Tomographic Imaging

    DTIC Science & Technology

    2013-08-01

    BPA ) to form an object image. As the data is collected radially about the axis of rotation, one computation method computes an inverse Fourier...images are not quite as sharp. It is concluded UNCLASSIFIED iii DSTO–RR–0394 UNCLASSIFIED that polar BPA processing requires an appropriate choice of...attenuation factor to reduce the effect of the specular reflections, while for the 2DIFT BPA approach the degrading effect from these reflections is

  10. The Rotation of M Dwarfs Observed by the Apache Point Galactic Evolution Experiment

    NASA Astrophysics Data System (ADS)

    Gilhool, Steven H.; Blake, Cullen H.; Terrien, Ryan C.; Bender, Chad; Mahadevan, Suvrath; Deshpande, Rohit

    2018-01-01

    We present the results of a spectroscopic analysis of rotational velocities in 714 M-dwarf stars observed by the SDSS-III Apache Point Galactic Evolution Experiment (APOGEE) survey. We use a template-fitting technique to estimate v\\sin i while simultaneously estimating {log}g, [{{M}}/{{H}}], and {T}{eff}. We conservatively estimate that our detection limit is 8 km s‑1. We compare our results to M-dwarf rotation studies in the literature based on both spectroscopic and photometric measurements. Like other authors, we find an increase in the fraction of rapid rotators with decreasing stellar temperature, exemplified by a sharp increase in rotation near the M4 transition to fully convective stellar interiors, which is consistent with the hypothesis that fully convective stars are unable to shed angular momentum as efficiently as those with radiative cores. We compare a sample of targets observed both by APOGEE and the MEarth transiting planet survey and find no cases where the measured v\\sin i and rotation period are physically inconsistent, requiring \\sin i> 1. We compare our spectroscopic results to the fraction of rotators inferred from photometric surveys and find that while the results are broadly consistent, the photometric surveys exhibit a smaller fraction of rotators beyond the M4 transition by a factor of ∼2. We discuss possible reasons for this discrepancy. Given our detection limit, our results are consistent with a bimodal distribution in rotation that is seen in photometric surveys.

  11. Giant enhancement of Faraday rotation due to electromagnetically induced transparency in all-dielectric magneto-optical metasurfaces.

    PubMed

    Christofi, Aristi; Kawaguchi, Yuma; Alù, Andrea; Khanikaev, Alexander B

    2018-04-15

    In this Letter we introduce a new class of Fano-resonant all-dielectric metasurfaces for enhanced, high figure of merit magneto-optical response. The metasurfaces are formed by an array of magneto-optical bismuth-substituted yttrium iron garnet nano-disks embedded into a low-index matrix. The strong field enhancement in the magneto-optical disks, which results in over an order of magnitude enhancement of Faraday rotation, is achieved by engineering two (electric and magnetic) resonances. It is shown that while enhancement of rotation also takes place for spectrally detuned resonances, the resonant excitation inevitably results in stronger reflection and low figure of merit of the device. We demonstrate that this can be circumvented by overlapping electric and magnetic resonances of the nanodisks, yielding a sharp electromagnetically induced transparency peak in the transmission spectrum, which is accompanied by gigantic Faraday rotation. Our results show that one can simultaneously obtain a large Faraday rotation enhancement along with almost 100% transmittance in an all-dielectric metasurface as thin as 300 nm. A simple analytical model based on coupled-mode theory is introduced to explain the effects observed in first-principle finite element method simulations.

  12. Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency: Twelve-Month Results of the DEFINITIVE AR Study.

    PubMed

    Zeller, Thomas; Langhoff, Ralf; Rocha-Singh, Krishna J; Jaff, Michael R; Blessing, Erwin; Amann-Vesti, Beatrice; Krzanowski, Marek; Peeters, Patrick; Scheinert, Dierk; Torsello, Giovanni; Sixt, Sebastian; Tepe, Gunnar

    2017-09-01

    Studies assessing drug-coated balloons (DCB) for the treatment of femoropopliteal artery disease are encouraging. However, challenging lesions, such as severely calcified, remain difficult to treat with DCB alone. Vessel preparation with directional atherectomy (DA) potentially improves outcomes of DCB. DEFINITIVE AR study (Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency-A Pilot Study of Anti-Restenosis Treatment) was a multicenter randomized trial designed to estimate the effect of DA before DCB to facilitate the development of future end point-driven randomized studies. One hundred two patients with claudication or rest pain were randomly assigned 1:1 to DA+DCB (n=48) or DCB alone (n=54), and 19 additional patients with severely calcified lesions were treated with DA+DCB. Mean lesion length was 11.2±4.0 cm for DA+DCB and 9.7±4.1 cm for DCB ( P =0.05). Predilation rate was 16.7% for DA+DCB versus 74.1% for DCB; postdilation rate was 6.3% for DA+DCB versus 33.3% for DCB. Technical success was superior for DA+DCB (89.6% versus 64.2%; P =0.004). Overall bail-out stenting rate was 3.7%, and rate of flow-limiting dissections was 19% for DCB and 2% for DA+DCB ( P =0.01). One-year primary outcome of angiographic percent diameter stenosis was 33.6±17.7% for DA+DCB versus 36.4±17.6% for DCB ( P =0.48), and clinically driven target lesion revascularization was 7.3% for DA+DCB and 8.0% for DCB ( P =0.90). Duplex ultrasound patency was 84.6% for DA+DCB, 81.3% for DCB ( P =0.78), and 68.8% for calcified lesions. Freedom from major adverse events at 1 year was 89.3% for DA+DCB and 90.0% for DCB ( P =0.86). DA+DCB treatment was effective and safe, but the study was not powered to show significant differences between the 2 methods of revascularization in 1-year follow-up. An adequately powered randomized trial is warranted. http://www.clinicaltrials.gov. Unique Identifier: NCT01366482. Copyright © 2017 The Author(s).

  13. Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency

    PubMed Central

    Langhoff, Ralf; Rocha-Singh, Krishna J.; Jaff, Michael R.; Blessing, Erwin; Amann-Vesti, Beatrice; Krzanowski, Marek; Peeters, Patrick; Scheinert, Dierk; Torsello, Giovanni; Sixt, Sebastian; Tepe, Gunnar

    2017-01-01

    Background— Studies assessing drug-coated balloons (DCB) for the treatment of femoropopliteal artery disease are encouraging. However, challenging lesions, such as severely calcified, remain difficult to treat with DCB alone. Vessel preparation with directional atherectomy (DA) potentially improves outcomes of DCB. Methods and Results— DEFINITIVE AR study (Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency—A Pilot Study of Anti-Restenosis Treatment) was a multicenter randomized trial designed to estimate the effect of DA before DCB to facilitate the development of future end point-driven randomized studies. One hundred two patients with claudication or rest pain were randomly assigned 1:1 to DA+DCB (n=48) or DCB alone (n=54), and 19 additional patients with severely calcified lesions were treated with DA+DCB. Mean lesion length was 11.2±4.0 cm for DA+DCB and 9.7±4.1 cm for DCB (P=0.05). Predilation rate was 16.7% for DA+DCB versus 74.1% for DCB; postdilation rate was 6.3% for DA+DCB versus 33.3% for DCB. Technical success was superior for DA+DCB (89.6% versus 64.2%; P=0.004). Overall bail-out stenting rate was 3.7%, and rate of flow-limiting dissections was 19% for DCB and 2% for DA+DCB (P=0.01). One-year primary outcome of angiographic percent diameter stenosis was 33.6±17.7% for DA+DCB versus 36.4±17.6% for DCB (P=0.48), and clinically driven target lesion revascularization was 7.3% for DA+DCB and 8.0% for DCB (P=0.90). Duplex ultrasound patency was 84.6% for DA+DCB, 81.3% for DCB (P=0.78), and 68.8% for calcified lesions. Freedom from major adverse events at 1 year was 89.3% for DA+DCB and 90.0% for DCB (P=0.86). Conclusions— DA+DCB treatment was effective and safe, but the study was not powered to show significant differences between the 2 methods of revascularization in 1-year follow-up. An adequately powered randomized trial is warranted. Clinical Trial Registration— http://www.clinicaltrials.gov. Unique Identifier: NCT01366482. PMID:28916599

  14. ORBIT II sub-analysis: Impact of impaired renal function following treatment of severely calcified coronary lesions with the Orbital Atherectomy System.

    PubMed

    Lee, Michael S; Lee, Arthur C; Shlofmitz, Richard A; Martinsen, Brad J; Hargus, Nick J; Elder, Mahir D; Généreux, Philippe; Chambers, Jeffrey W

    2017-04-01

    To investigate the safety and efficacy of the coronary Orbital Atherectomy System (OAS) to prepare severely calcified lesions for stent deployment in patients grouped by renal function. Percutaneous coronary intervention (PCI) of severely calcified lesions is associated with increased rates of major adverse cardiac events (MACE), including death, myocardial infarction (MI), and target vessel revascularization (TVR) compared with PCI of non-calcified vessels. Patients with chronic kidney disease (CKD) are at increased risk for MACE after PCI. The impact of CKD on coronary orbital atherectomy treatment has not been well characterized. ORBIT II was a prospective, multicenter trial in the U.S., which enrolled 443 patients with severely calcified coronary lesions. The MACE rate was defined as a composite of cardiac death, MI, and target vessel revascularization. Of the 441 patients enrolled with known estimated glomerular filtration rate (eGFR) values at baseline, 333 (75.5%) patients had eGFR < 90 ml/min/1.73 m 2 and 108 patients had eGFR ≥ 90 ml/min/1.73 m 2 . The mean eGFR at baseline in the eGFR < 90 ml/min/1.73 m 2 and eGFR ≥ 90 ml/min/1.73 m 2 groups was 65.0 ± 0.9 ml/min/1.73 m 2 and 109.1 ± 2.0 ml/min/1.73 m 2 , respectively. Freedom from MACE was lower in the eGFR < 90 ml/min/1.73 m 2 group at 30 days (87.4% vs. 96.3%, P = 0.02) and 1-year (80.6% vs. 90.7%, P = 0.02). Patients with renal impairment had a higher MACE rate through one year follow-up due to a higher rate of periprocedural MI. Interestingly, the rates of cardiac death and revascularization through 1-year were similar in patients with eGFR < 90 ml/min/1.73 m 2 and eGFR ≥ 90 ml/min/1.73 m 2 . Future studies are needed to identify the ideal revascularization strategy for patients with renal impairment and severely calcified coronary lesions. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  15. Photogeological analysis of Europan tectonic features

    NASA Technical Reports Server (NTRS)

    Tufts, B. R.

    1993-01-01

    Preliminary photogeological analyses of the Pelorus Linea and Sidon Flexus regions of Europa were conducted to explore the proposal by Schenk that lateral motion of crustal blocks has occurred in a 'rift zone' including possible strike-slip, tension fracturing, and geometric plate rotation about an Euler pole. These analyses revealed features interpreted as tensional structures and block rotation in a strike-slip regime consistent with the Schenk hypotheses and implied the presence of at least two stages of crustal deformation consistent with a chronology developed by Lucchitta. Confirmation of regional scale Euler pole rotation was ambiguous, however. Up to 80 kilometers of possible extension was identified in the rift zone; to accommodate this, 'cryosubduction' is speculatively proposed as a mechanism for recycling Europan 'ice lithosphere'. The cumulative width of wedge-shaped bands included in the rift zone was measured and plotted versus distance from the inferred rotation pole. Three sharp decreases in the total width were noted. These occur roughly where certain triple bands cross the rift zone suggesting that the bands are structural features that predate and influence the zone. While the curve hints at one or more sinusoidal relationships consistent with rotation geometry, given the low photographic resolution and the preliminary nature of this examination the question of whether the observations represent coherent regional rotation modified by crosscutting structures or instead imply independent local rotations separated by these structures is unanswered by this analysis.

  16. Using the modern Silverhawk™ atherectomy catheter to characterize biliary structures that appear malignant: review of initial experience

    PubMed Central

    Schwartz, Jason J; Thiesset, Heather F; Clayton, Frederic; Adler, Douglas G; Hutson, William R; Carlisle, James G

    2011-01-01

    Background Diagnosis of a biliary stricture often hinges on cytological interpretation. In the absence of accompanying stroma, these results can often be equivocal. In theory, advanced shave biopsy techniques would allow for the preservation of tissue architecture and a more accurate definition of biliary pathology. Objectives We sought to determine the initial diagnostic utility of the modern Silverhawk™ atherectomy (SA) catheter in the evaluation of biliary strictures that appear to be malignant. Methods A total of 141 patients with biliary pathology were identified during a retrospective review of medical records for the years 2006–2011. The SA catheter was employed 12 times in seven patients for whom a tissue diagnosis was otherwise lacking. Results Neoplasia was definitively excluded in seven specimens from four patients. These four individuals were followed for 1–5 years to exclude the development of cholangiocarcinoma (CC). Samples were positive for CC in three patients, one of whom became eligible for neoadjuvant therapy and orthotopic liver transplantation. Conclusions The SA catheter appears to be a useful adjunct in diagnosing patients with biliary pathology. The existence of this technique, predicated on tissue architecture, may impact therapy, allow more timely diagnosis, and exclude cases of equivocal cytology. Although the initial results of SA use are promising, more experience is required to effectively determine its clinical accuracy. PMID:21999597

  17. Orbital Atherectomy Plaque Modification Assessment of the Femoropopliteal Artery Via Intravascular Ultrasound (TRUTH Study)

    PubMed Central

    Zavlunova, Susanna; Attubato, Michael J.; Martinsen, Brad J.; Mintz, Gary S.; Maehara, Akiko

    2015-01-01

    Objective: The Tissue Removal Assessment with Ultrasound of the SFA and Popliteal (TRUTH) study assessed the performance of the orbital atherectomy system (OAS) to treat femoropopliteal arteries, including determining its effect on plaque removal. Methods: Patients with symptomatic femoropopliteal peripheral arterial disease were treated with the OAS followed by adjunctive balloon angioplasty (BA). Intravascular ultrasound (IVUS) images were collected pre- and post-OAS and post-OAS BA. Patients were followed through 12 months post-procedure. Results: Twenty-nine lesions were treated with OAS-BA in 25 patients. The mean maximum balloon inflation pressure was 5.2 ± 1.2 atm. Virtual histology IVUS (VH-IVUS) analysis revealed at the maximum calcium ablation site that calcium reduction was responsible for 86% of the lumen area increase. The minimum lumen area increased from 4.0 mm2 to 9.1 mm2 (<.0001), and the percentage of area stenosis decreased from 76.9% to 43.0% (<.0001) after OAS-BA. At 12 months, the target lesion revascularization rate was 8.2%, and ankle–brachial index and Rutherford classification improved significantly from baseline through follow-up. Conclusion: The VH-IVUS analysis reveals that OAS modifies the calcified component of the plaque burden. It is hypothesized that calcium modification by OAS changes the lesion compliance, allowing for low pressure adjunctive BA. The clinical outcomes were favorable through 12-month follow-up. PMID:26490645

  18. Combined use of directional atherectomy and drug-coated balloon for the endovascular treatment of common femoral artery disease: immediate and one-year outcomes.

    PubMed

    Cioppa, Angelo; Stabile, Eugenio; Salemme, Luigi; Popusoi, Grigore; Pucciarelli, Armando; Iacovelli, Fortunato; Arcari, Antonella; Coscioni, Enrico; Trimarco, Bruno; Esposito, Giovanni; Tesorio, Tullio

    2017-02-20

    Surgical endarterectomy is the therapy of choice for atherosclerotic common femoral artery (CFA) obstruction. Recently, some large single-centre series have shown encouraging results for the percutaneous treatment of CFA obstructions. The purpose of this study was to evaluate the safety, feasibility, and one-year efficacy of the endovascular treatment of CFA obstructions with combined use of directional atherectomy (DA) and a paclitaxel-coated balloon (DCB). Between January 2012 and July 2014, 30 consecutive patients with severely calcified obstructions of the common femoral artery were treated in our centre using DA followed by DCB dilatation. Provisional stenting was allowed in the case of a suboptimal result. Twenty cases (66%) were isolated CFA interventions, whereas five (17%) and five (17%) also involved inflow and outflow vessels, respectively. Chronic total CFA occlusions (CTO) were recanalised in six cases (20%). Procedural success was achieved in all cases; stenting was needed in three cases (10%). At one year, restenosis and target lesion revascularisation were observed in two of 30 (6.6%) and one of 30 (3.3%) patients, respectively. The secondary patency rate was 96.7%. This single-centre prospective study suggests that the combined use of DA and DCB is a safe and effective alternative to surgery, a treatment option for common femoral artery lesions and provides encouraging results in this setting.

  19. Orbital Atherectomy Plaque Modification Assessment of the Femoropopliteal Artery Via Intravascular Ultrasound (TRUTH Study).

    PubMed

    Babaev, Anvar; Zavlunova, Susanna; Attubato, Michael J; Martinsen, Brad J; Mintz, Gary S; Maehara, Akiko

    2015-10-01

    The Tissue Removal Assessment with Ultrasound of the SFA and Popliteal (TRUTH) study assessed the performance of the orbital atherectomy system (OAS) to treat femoropopliteal arteries, including determining its effect on plaque removal. Patients with symptomatic femoropopliteal peripheral arterial disease were treated with the OAS followed by adjunctive balloon angioplasty (BA). Intravascular ultrasound (IVUS) images were collected pre- and post-OAS and post-OAS BA. Patients were followed through 12 months post-procedure. Twenty-nine lesions were treated with OAS-BA in 25 patients. The mean maximum balloon inflation pressure was 5.2 ± 1.2 atm. Virtual histology IVUS (VH-IVUS) analysis revealed at the maximum calcium ablation site that calcium reduction was responsible for 86% of the lumen area increase. The minimum lumen area increased from 4.0 mm(2) to 9.1 mm(2) (<.0001), and the percentage of area stenosis decreased from 76.9% to 43.0% (<.0001) after OAS-BA. At 12 months, the target lesion revascularization rate was 8.2%, and ankle-brachial index and Rutherford classification improved significantly from baseline through follow-up. The VH-IVUS analysis reveals that OAS modifies the calcified component of the plaque burden. It is hypothesized that calcium modification by OAS changes the lesion compliance, allowing for low pressure adjunctive BA. The clinical outcomes were favorable through 12-month follow-up. © The Author(s) 2015.

  20. A beam-splitter-type 3-D endoscope for front view and front-diagonal view images.

    PubMed

    Kamiuchi, Hiroki; Masamune, Ken; Kuwana, Kenta; Dohi, Takeyoshi; Kim, Keri; Yamashita, Hiromasa; Chiba, Toshio

    2013-01-01

    In endoscopic surgery, surgeons must manipulate an endoscope inside the body cavity to observe a large field-of-view while estimating the distance between surgical instruments and the affected area by reference to the size or motion of the surgical instruments in 2-D endoscopic images on a monitor. Therefore, there is a risk of the endoscope or surgical instruments physically damaging body tissues. To overcome this problem, we developed a Ø7- mm 3-D endoscope that can switch between providing front and front-diagonal view 3-D images by simply rotating its sleeves. This 3-D endoscope consists of a conventional 3-D endoscope and an outer and inner sleeve with a beam splitter and polarization plates. The beam splitter was used for visualizing both the front and front-diagonal view and was set at 25° to the outer sleeve's distal end in order to eliminate a blind spot common to both views. Polarization plates were used to avoid overlap of the two views. We measured signal-to-noise ratio (SNR), sharpness, chromatic aberration (CA), and viewing angle of this 3-D endoscope and evaluated its feasibility in vivo. Compared to the conventional 3-D endoscope, SNR and sharpness of this 3-D endoscope decreased by 20 and 7 %, respectively. No significant difference was found in CA. The viewing angle for both the front and front-diagonal views was about 50°. In the in vivo experiment, this 3-D endoscope can provide clear 3-D images of both views by simply rotating its inner sleeve. The developed 3-D endoscope can provide the front and front-diagonal view by simply rotating the inner sleeve, therefore the risk of damage to fragile body tissues can be significantly decreased.

  1. The nature of the late B-type stars HD 67044 and HD 42035

    NASA Astrophysics Data System (ADS)

    Monier, R.; Gebran, M.; Royer, F.

    2016-04-01

    While monitoring a sample of apparently slowly rotating superficially normal bright late B and early A stars in the northern hemisphere, we have discovered that HD 67044 and HD 42035, hitherto classified as normal late B-type stars, are actually respectively a new chemically peculiar star and a new spectroscopic binary containing a very slow rotator HD 42035 S with ultra-sharp lines (v_{{e}}sin i= 3.7 km s^{-1}) and a fast rotator HD 42035 B with broad lines. The lines of Ti ii, Cr ii, Mn ii, Sr ii, Y ii, Zr ii and Ba ii are conspicuous features in the high resolution SOPHIE spectrum (R=75000) of HD 67044. The Hg ii line at 3983.93 Å is also present as a weak feature. The composite spectrum of HD 42035 is characterised by very sharp lines formed in HD 42035 S superimposed onto the shallow and broad lines of HD 42035 B. These very sharp lines are mostly due to light elements from C to Ni, the only heavy species definitely present are strontium and barium. Selected lines of 21 chemical elements from He up to Hg have been synthesized using model atmospheres computed with ATLAS9 and the spectrum synthesis code SYNSPEC48 including hyperfine structure of various isotopes when relevant. These synthetic spectra have been adjusted to high resolution high signal-to-noise spectra of HD 67044 and HD 42035 S in order to derive abundances of these key elements. HD 67044 is found to have distinct enhancements of Ti, Cr, Mn, Sr, Y, Zr, Ba and Hg and underabundances in He, C, O, Ca and Sc which shows that this star is not a superficially normal late B-type star, but actually is a new CP star most likely of the HgMn type. HD 42035 S has provisional underabundances of the light elements from C to Ti and overabundances of heavier elements (except for Fe and Sr which are also underabundant) up to barium. These values are lower limits to the actual abundances as we cannot currently place properly the continuum of HD 42035 S. More accurate fundamental parameters and abundances for HD 42035 S and HD 42035 B will be derived if we manage to disentangle their spectra. They will help clarify the status of the two components in this interesting new spectroscopic binary.

  2. Electronic differential for tramcar bogies: system development and performance evaluation by means of numerical simulation

    NASA Astrophysics Data System (ADS)

    Barbera, Andrea N.; Bucca, Giuseppe; Corradi, Roberto; Facchinetti, Alan; Mapelli, Ferdinando

    2014-05-01

    The dynamic behaviour of railway vehicles depends on the wheelset configuration, i.e. solid axle wheelset or independently rotating wheels (IRWs). The self-centring behaviour, peculiar of the solid axle wheelset, makes this kind of wheelset very suitable for tangent track running at low speed: the absence of the self-centring mechanism in the IRWs may lead to anomalous wheel/rail wear, reduced vehicle safety and passengers' discomfort. On the contrary, during negotiation of the sharp curves typical of urban tramways, solid axle wheelsets produce lateral contact forces higher than those of IRWs. This paper illustrates an electronic differential system to be applied to tramcar bogies equipped with wheel-hub motors which allows switching from solid axle in tangent track to IRWs in sharp curve (and vice versa). An electro-mechanical vehicle model is adopted for the design of the control system and for the evaluation of the vehicle dynamic performances.

  3. Shear banding, discontinuous shear thickening, and rheological phase transitions in athermally sheared frictionless disks

    NASA Astrophysics Data System (ADS)

    Vâgberg, Daniel; Olsson, Peter; Teitel, S.

    2017-05-01

    We report on numerical simulations of simple models of athermal, bidisperse, soft-core, massive disks in two dimensions, as a function of packing fraction ϕ , inelasticity of collisions as measured by a parameter Q , and applied uniform shear strain rate γ ˙. Our particles have contact interactions consisting of normally directed elastic repulsion and viscous dissipation, as well as tangentially directed viscous dissipation, but no interparticle Coulombic friction. Mapping the phase diagram in the (ϕ ,Q ) plane for small γ ˙, we find a sharp first-order rheological phase transition from a region with Bagnoldian rheology to a region with Newtonian rheology, and show that the system is always Newtonian at jamming. We consider the rotational motion of particles and demonstrate the crucial importance that the coupling between rotational and translational degrees of freedom has on the phase structure at small Q (strongly inelastic collisions). At small Q , we show that, upon increasing γ ˙, the sharp Bagnoldian-to-Newtonian transition becomes a coexistence region of finite width in the (ϕ ,γ ˙) plane, with coexisting Bagnoldian and Newtonian shear bands. Crossing this coexistence region by increasing γ ˙ at fixed ϕ , we find that discontinuous shear thickening can result if γ ˙ is varied too rapidly for the system to relax to the shear-banded steady state corresponding to the instantaneous value of γ ˙.

  4. Resonances in the Field-Angle-Resolved Thermal Conductivity of CeCoIn 5

    DOE PAGES

    Kim, Duk Y.; Lin, Shi -Zeng; Weickert, Franziska; ...

    2017-05-12

    Here, the thermal conductivity measurement in a rotating magnetic field is a powerful probe of the structure of the superconducting energy gap. We present high-precision measurements of the low-temperature thermal conductivity in the unconventional heavy-fermion superconductor CeCoIn 5, with the heat current J along the nodal [110] direction of its d x2–y2 order parameter and the magnetic field up to 7 T rotating in the ab plane. In contrast to the smooth oscillations found previously for J∥[100], we observe a sharp resonancelike peak in the thermal conductivity when the magnetic field is also in the [110] direction, parallel to themore » heat current. We explain this peak qualitatively via a model of the heat transport in a d-wave superconductor. In addition, we observe two smaller but also very sharp peaks in the thermal conductivity for the field directions at angles Θ≈±33° with respect to J. The origin of the observed resonances at Θ≈±33° at present defies theoretical explanation. The challenge of uncovering their source will dictate exploring theoretically more complex models, which might include, e.g., fine details of the Fermi surface, Andreev bound vortex core states, a secondary superconducting order parameter, and the existence of gaps in spin and charge excitations.« less

  5. Resonances in the Field-Angle-Resolved Thermal Conductivity of CeCoIn 5

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Duk Y.; Lin, Shi -Zeng; Weickert, Franziska

    Here, the thermal conductivity measurement in a rotating magnetic field is a powerful probe of the structure of the superconducting energy gap. We present high-precision measurements of the low-temperature thermal conductivity in the unconventional heavy-fermion superconductor CeCoIn 5, with the heat current J along the nodal [110] direction of its d x2–y2 order parameter and the magnetic field up to 7 T rotating in the ab plane. In contrast to the smooth oscillations found previously for J∥[100], we observe a sharp resonancelike peak in the thermal conductivity when the magnetic field is also in the [110] direction, parallel to themore » heat current. We explain this peak qualitatively via a model of the heat transport in a d-wave superconductor. In addition, we observe two smaller but also very sharp peaks in the thermal conductivity for the field directions at angles Θ≈±33° with respect to J. The origin of the observed resonances at Θ≈±33° at present defies theoretical explanation. The challenge of uncovering their source will dictate exploring theoretically more complex models, which might include, e.g., fine details of the Fermi surface, Andreev bound vortex core states, a secondary superconducting order parameter, and the existence of gaps in spin and charge excitations.« less

  6. THE FORMATION OF ROTATIONAL DISCONTINUITIES IN COMPRESSIVE THREE-DIMENSIONAL MHD TURBULENCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Liping; Feng, Xueshang; Zhang, Lei

    Measurements of solar wind turbulence reveal the ubiquity of discontinuities. In this study we investigate how the discontinuities, especially rotational discontinuities (RDs), are formed in MHD turbulence. In a simulation of the decaying compressive three-dimensional (3D) MHD turbulence with an imposed uniform background magnetic field, we detect RDs with sharp field rotations and little variations of magnetic field intensity, as well as mass density. At the same time, in the de Hoffman–Teller frame, the plasma velocity is nearly in agreement with the Alfvén speed, and is field-aligned on both sides of the discontinuity. We take one of the identified RDsmore » to analyze its 3D structure and temporal evolution in detail. By checking the magnetic field and plasma parameters, we find that the identified RD evolves from the steepening of the Alfvén wave with moderate amplitude, and that steepening is caused by the nonuniformity of the Alfvén speed in the ambient turbulence.« less

  7. Importance of counter-rotating coupling in the superfluid-to-Mott-insulator quantum phase transition of light in the Jaynes-Cummings lattice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng Hang; Takada, Yasutami

    2011-10-15

    The quantum phase transition between Mott insulator and superfluid is studied in the two-dimensional Jaynes-Cummings square lattice in which the counter-rotating coupling (CRC) is included. Both the ground state and the spectra of low-lying excitations are obtained with use of a sophisticated unitary transformation. This CRC is shown not only to induce a long-range interaction between cavities, favoring the long-range superfluid order, but also to break the conservation of local polariton number at each site, leading to the absence of the Mott lobes in the phase diagram, in sharp contrast with the case without the CRC as well as thatmore » of the Bose-Hubbard model.« less

  8. A quality evaluation of stabilization of rotation frequency of gas-diesel engines when using an adaptive automatic control system

    NASA Astrophysics Data System (ADS)

    Zhilenkov, A. A.; Efremov, A. A.

    2017-02-01

    A possibility of quality improvement of stabilization of rotation frequency of the gas-diesels used as prime mover of generator set in the multigenerator units working for abruptly variable load of large power is considered. An evaluation is made on the condition of fuzzy controller use developed and described by the authors in a number of articles. An evaluation has shown that theoretically, the revolution range of a gas-diesel engine may be reduced 25-30 times in case of optimal settings of the controller in the whole power range. The results of modelling showing a considerable quality improvement of transient processes in the investigated system during a sharp change of loading are presented in this article.

  9. Technique optimization of orbital atherectomy in calcified peripheral lesions of the lower extremities: the CONFIRM series, a prospective multicenter registry.

    PubMed

    Das, Tony; Mustapha, Jihad; Indes, Jeffrey; Vorhies, Robert; Beasley, Robert; Doshi, Nilesh; Adams, George L

    2014-01-01

    The purpose of CONFIRM registry series was to evaluate the use of orbital atherectomy (OA) in peripheral lesions of the lower extremities, as well as optimize the technique of OA. Methods of treating calcified arteries (historically a strong predictor of treatment failure) have improved significantly over the past decade and now include minimally invasive endovascular treatments, such as OA with unique versatility in modifying calcific lesions above and below-the-knee. Patients (3135) undergoing OA by more than 350 physicians at over 200 US institutions were enrolled on an "all-comers" basis, resulting in registries that provided site-reported patient demographics, ABI, Rutherford classification, co-morbidities, lesion characteristics, plaque morphology, device usage parameters, and procedural outcomes. Treatment with OA reduced pre-procedural stenosis from an average of 88-35%. Final residual stenosis after adjunctive treatments, typically low-pressure percutaneous transluminal angioplasty (PTA), averaged 10%. Plaque removal was most effective for severely calcified lesions and least effective for soft plaque. Shorter spin times and smaller crown sizes significantly lowered procedural complications which included slow flow (4.4%), embolism (2.2%), and spasm (6.3%), emphasizing the importance of treatment regimens that focus on plaque modification over maximizing luminal gain. The OA technique optimization, which resulted in a change of device usage across the CONFIRM registry series, corresponded to a lower incidence of adverse events irrespective of calcium burden or co-morbidities. Copyright © 2013 The Authors. Wiley Periodicals, Inc.

  10. Column formation and hysteresis in a two-fluid tornado

    NASA Astrophysics Data System (ADS)

    Sharifullin, B. R.; Naumov, I. V.; Herrada, M. A.; Shtern, V. N.

    2018-03-01

    This experimental and numerical study addresses a flow of water and sunflower oil. This flow is driven by the rotating lid in a sealed vertical cylinder. The experiments were performed in a glass container with a radius of 45 mm and a height of 45 mm with the water volume fraction of 20%. Different densities and immiscibility of liquids provide the stable and sharp interface. At the rest, the interface is flat and horizontal. As the rotation speeds up, a new water-flow cell emerges near the bottom center. This cell expands and occupies almost the entire water domain while the initial water circulation shrinks into a thin layer adjacent to the interface. The water, rising near the container axis, strongly deforms the interface (upward near the axis and downward near the sidewall). A new oil-flow cell emerges above the interface near the axis. This cell disappears as the interface approaches the lid. The water separates from the sidewall, reaches the lid, and forms a column. As the rotation is decreased, the scenario reverses, but the flow states differ from those for the increasing rotation, i.e., a hysteresis is observed. The numerical simulations agree with the experiment and help explain the flow metamorphoses.

  11. Liquid-film electron stripper

    DOEpatents

    Leemann, Beat T.; Yourd, Roland B.

    1984-01-01

    A thin freestanding oil film is produced in vacuum by directing an oil stream radially inward to the hollow-ground sharp outer edge of a rotating disc. The sides of the edge are roughened somewhat to aid in dispersing oil from the disc. Oil is removed from the surface of disc to prevent formation of oil droplets which might spin off the disc and disrupt the oil film. An ion beam is directed through the thin oil film so that electrons are stripped from the ions to increase their charge.

  12. Liquid-film electron stripper

    DOEpatents

    Leemann, B.T.; Yourd, R.B.

    1982-03-09

    A thin freestanding oil film is produced in vacuum by directing an oil stream radially inward to the hollow-ground sharp outer edge of a rotating disc. The sides of the edge are roughened somewhat to aid in dispersing oil from the disc. Oil is removed from the surface of disc to prevent formation of oil droplets which might spin off the disc and disrupt the oil film. An ion beam is directed through the thin oil film so that electrons are stripped from the ions to increase their charge.

  13. Optical Tamm states in one-dimensional magnetophotonic structures.

    PubMed

    Goto, T; Dorofeenko, A V; Merzlikin, A M; Baryshev, A V; Vinogradov, A P; Inoue, M; Lisyansky, A A; Granovsky, A B

    2008-09-12

    We demonstrate the existence of a spectrally narrow localized surface state, the so-called optical Tamm state, at the interface between one-dimensional magnetophotonic and nonmagnetic photonic crystals. The state is spectrally located inside the photonic band gaps of each of the photonic crystals comprising this magnetophotonic structure. This state is associated with a sharp transmission peak through the sample and is responsible for the substantial enhancement of the Faraday rotation for the corresponding wavelength. The experimental results are in excellent agreement with the theoretical predictions.

  14. Conservative Management of Uncomplicated Mechanical Neck Pain in a Military Aviator

    DTIC Science & Technology

    2010-01-01

    head to the right. The neck pain became more bothersome during and after ACM. Typically the pain was described as being dull and aching in...outcome of exposure to high gravi- tational (G) forces.2 The weight of the helmet and oxygen mask and the various non-neutral head postures assumed when...character; however it could become sharp with rapid right rotation of the neck or under high G situations. He experienced diffi culty turning his head to

  15. Dynamic modeling for rigid rotor bearing systems with a localized defect considering additional deformations at the sharp edges

    NASA Astrophysics Data System (ADS)

    Liu, Jing; Shao, Yimin

    2017-06-01

    Rotor bearing systems (RBSs) play a very valuable role for wind turbine gearboxes, aero-engines, high speed spindles, and other rotational machinery. An in-depth understanding of vibrations of the RBSs is very useful for condition monitoring and diagnosis applications of these machines. A new twelve-degree-of-freedom dynamic model for rigid RBSs with a localized defect (LOD) is proposed. This model can formulate the housing support stiffness, interfacial frictional moments including load dependent and load independent components, time-varying displacement excitation caused by a LOD, additional deformations at the sharp edges of the LOD, and lubricating oil film. The time-varying displacement model is determined by a half-sine function. A new method for calculating the additional deformations at the sharp edges of the LOD is analytical derived based on an elastic quarter-space method presented in the literature. The proposed dynamic model is utilized to analyze the influences of the housing support stiffness and LOD sizes on the vibration characteristics of the rigid RBS, which cannot be predicted by the previous dynamic models in the literature. The results show that the presented method can give a new dynamic modeling method for vibration formulation for a rigid RBS with and without the LOD on the races.

  16. Spreading out and staying sharp - creating diverse rotation curves via baryonic and self-interaction effects

    NASA Astrophysics Data System (ADS)

    Creasey, Peter; Sameie, Omid; Sales, Laura V.; Yu, Hai-Bo; Vogelsberger, Mark; Zavala, Jesús

    2017-06-01

    Galactic rotation curves are a fundamental constraint for any cosmological model. We use controlled N-body simulations of galaxies to study the gravitational effect of baryons in a scenario with collisionless cold dark matter (CDM) versus one with a self-interacting dark matter (SIDM) component. In particular, we examine the inner profiles of the rotation curves in the velocity range Vmax = [30-250] km s-1, whose diversity has been found to be greater than predicted by the ΛCDM scenario. We find that the scatter in the observed rotation curves exceeds that predicted by dark matter only mass-concentration relations in either the CDM nor SIDM models. Allowing for realistic baryonic content and spatial distributions, however, helps create a large variety of rotation curve shapes, which is in a better agreement with observations in the case of self-interactions due to the characteristic cored profiles being more accommodating to the slowly rising rotation curves than CDM. We find individual fits to model two of the most remarkable outliers of similar Vmax, UGC 5721 and IC 2574 - the former a cusp-like rotation curve and the latter a seemingly 8-kpc-cored profile. This diversity in SIDM arises as permutations of overly concentrated haloes with compact baryonic distributions versus underdense haloes with extended baryonic discs. The SIDM solution is promising and its feasibility ultimately depends on the sampling of the halo mass-concentration relation and its interplay with the baryonic profiles, emphasizing the need for a better understanding of the frequency of extreme outliers present in current observational samples.

  17. The SLUGGS survey: globular cluster kinematics in a `double sigma' galaxy - NGC 4473

    NASA Astrophysics Data System (ADS)

    Alabi, Adebusola B.; Foster, Caroline; Forbes, Duncan A.; Romanowsky, Aaron J.; Pastorello, Nicola; Brodie, Jean P.; Spitler, Lee R.; Strader, Jay; Usher, Christopher

    2015-09-01

    NGC 4473 is a so-called double sigma (2σ) galaxy, i.e. a galaxy with rare, double peaks in its 2D stellar velocity dispersion. Here, we present the globular cluster (GC) kinematics in NGC 4473 out to ˜10Re (effective radii) using data from combined Hubble Space Telescope/Advanced Camera for Surveys and Subaru/Suprime-Cam imaging and Keck/Deep Imaging Multi-Object Spectrograph. We find that the 2σ nature of NGC 4473 persists up to 3Re, though it becomes misaligned to the photometric major axis. We also observe a significant offset between the stellar and GC rotation amplitudes. This offset can be understood as a co-addition of counter-rotating stars producing little net stellar rotation. We identify a sharp radial transition in the GC kinematics at ˜4Re suggesting a well defined kinematically distinct halo. In the inner region (<4Re), the blue GCs rotate along the photometric major axis, but in an opposite direction to the galaxy stars and red GCs. In the outer region (>4Re), the red GCs rotate in an opposite direction compared to the inner region red GCs, along the photometric major axis, while the blue GCs rotate along an axis intermediate between the major and minor photometric axes. We also find a kinematically distinct population of very red GCs in the inner region with elevated rotation amplitude and velocity dispersion. The multiple kinematic components in NGC 4473 highlight the complex formation and evolutionary history of this 2σ galaxy, as well as a distinct transition between the inner and outer components.

  18. INTERNAL ROTATION OF THE RED-GIANT STAR KIC 4448777 BY MEANS OF ASTEROSEISMIC INVERSION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Mauro, M. P.; Cardini, D.; Ventura, R.

    We study the dynamics of the stellar interior of the early red-giant star KIC 4448777 by asteroseismic inversion of 14 splittings of the dipole mixed modes obtained from Kepler observations. In order to overcome the complexity of the oscillation pattern typical of red-giant stars, we present a procedure to extract the rotational splittings from the power spectrum. We find not only that the core rotates from a minimum of 8 to a maximum of 17 times faster than the surface, confirming previous inversion results generated for other red giants (Deheuvels et al.), but we also estimate the variation of the angularmore » velocity within the helium core with a spatial resolution of 0.001R and verify the hypothesis of a sharp discontinuity in the inner stellar rotation. The results show that the entire core rotates rigidly and provide evidence for an angular velocity gradient around the base of the hydrogen-burning shell; however, we do not succeed in characterizing the rotational slope, due to the intrinsic limits of the applied techniques. The angular velocity, from the edge of the core, appears to decrease with increasing distance from the center, reaching an average value in the convective envelope of 68 ± 22 nHz. We conclude that a set of data that includes only dipolar modes is sufficient to infer quite accurately the rotation of a red giant not only in the dense core but also, with a lower level of confidence, in part of the radiative region and in the convective envelope.« less

  19. Studies on the concentration dependence of specific rotation of Alpha lactose monohydrate (α-LM) aqueous solutions and growth of α-LM single crystals

    NASA Astrophysics Data System (ADS)

    Vinodhini, K.; Divya Bharathi, R.; Srinivasan, K.

    2018-02-01

    Lactose is an optically active substance. As it is one of the reducing sugars, exhibits mutarotation in solution when it dissolves in any solvent. In solution, lactose exists in two isomeric forms, alpha-Lactose (α-L) and beta-lactose (β-L) through the mutarotation reaction. Mutarotation produces a dynamic equilibrium between two isomers in a solution and kinetics of this process determines the growth rate of alpha lactose monohydrate (α-LM) crystals. Since no data were available on the specific rotation of aqueous α-LM solutions at different concentrations at 33 °C, the initial experiments were carried out on the specific rotation of aqueous α-LM solutions at different concentrations at 33 °C. The specific rotations of the solutions were decreased with increasing time through the mutarotation reaction. The initial and final (equilibrium) specific rotations of the solutions were determined by using automatic digital polarimeter. The compositions of α and β-L in all prepared solutions were calculated from initial and final optical rotations by the method of Sharp and Doob. The composition of α-L decreased whereas, the composition of β-L increased in solutions with increasing concentration of α-LM at 33 °C. Experimental results revealed that this method could be easily and safely employed to study the dependence of specific rotation of solutions on their concentration. The effect of β-lactose on the morphology of nucleated α-LM single crystals has been studied at different experimental conditions.

  20. Effect of ring rotation upon gas adsorption in SIFSIX-3-M (M = Fe, Ni) pillared square grid networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elsaidi, Sameh K.; Mohamed, Mona H.; Simon, Cory M.

    The study of the mobility/rotation of the organic linkers in porous metal-organic frameworks could provide a valuable information about the guest/framework interaction and the factors control the kinetics of adsorption. Here, we analyzed the dynamics of pyrazine ring rotation in a series of pillared square grid frameworks, namely SIFSIX-3-M (M = Fe, Ni). It was found that the rotation of pyrazine ring is influenced by the variation of metal cation, temperature and the guest molecule. The Fe-analogue, [Fe(pz)2(SiF6)2] (pz= Pyrazine), , showed no pronounced ring rotation and exhibited a high affinity toward Xe gas over Kr as exemplified by themore » sharp Xe uptake at low loading (~0.1 bar) and its high isosteric heat of adsorption (Qst~ 27.4 kJmol-1) compared to the current benchmark materials. The Ni analogue, on the contrary, showed a two-regime adsorption isotherm for Xe with a temperature-dependent inflection point. However, this behavior is not observed with the other gases such as CO2, N2, and Kr which showed one-step adsorption isotherms without any inflection. Using molecular models and simulations, we hypothesize that the inflection point is due to a disordered to ordered transition of the rotational configurations of the pz rings in SIFSIX-3-Ni. These results further support the impact of tuning the pore size and chemistry on the adsorption behavior of porous materials.« less

  1. Shape matters: improved flight in tapered auto-rotating wings

    NASA Astrophysics Data System (ADS)

    Liu, Yucen; Vincent, Lionel; Kanso, Eva

    2017-11-01

    Many plants use gravity and wind to disperse their seeds. The shape of seed pods influence their aerodynamics. For example, Liana seeds form aerodynamic gliders and Sycamore trees release airborne ``helicopters.'' Here, we use carefully-controlled experiments and high-speed photography to examine dispersion by tumbling (auto-rotation) and we focus on the effect of geometry on flight characteristics. We consider four families of shapes: rectangular, elliptic, tapered, and sharp-tip wings, and we vary the span-to-chord ratio. We find that tapered wings exhibit extended flight time and range, that is, better performance. A quasi-steady two-dimensional model is used to highlight the mechanisms by which shape affects flight performance. These findings could have significant implications on linking seedpod designs to seed dispersion patterns as well as on optimizing wing design in active flight problems.

  2. Resonant vibrational-excitation cross sections and rate constants for low-energy electron scattering by molecular oxygen

    NASA Astrophysics Data System (ADS)

    Laporta, V.; Celiberto, R.; Tennyson, J.

    2013-04-01

    Resonant vibrational-excitation cross sections and rate constants for electron scattering by molecular oxygen are presented. Transitions between all 42 vibrational levels of O_2({X}\\, ^3\\Sigma_g^{-}) are considered. Molecular rotations are parametrized by the rotational quantum number J, which is considered in the range 1-151. The lowest four resonant states of O_2^- , 2Πg, 2Πu, ^4\\Sigma_u^- and ^2\\Sigma_u^- are taken into account. The calculations are performed using the fixed-nuclei R-matrix approach to determine the resonance positions and widths, and the boomerang model to characterize the nuclei motion. Two energy regions below and above 4 eV are investigated: the first one is characterized by sharp structures in the cross section and the second by a broad resonance peaked at 10 eV. The computed cross sections are compared with theoretical and experimental results available in the literature for both energy regions, and are made available for use by modelers. The effect of including rotational motion is found to be non-negligible.

  3. Diffraction effects in mechanically chopped laser pulses

    NASA Astrophysics Data System (ADS)

    Gambhir, Samridhi; Singh, Mandip

    2018-06-01

    A mechanical beam chopper consists of a rotating disc of regularly spaced wide slits which allow light to pass through them. A continuous light beam, after passing through the rotating disc, is switched-on and switched-off periodically, and a series of optical pulses are produced. The intensity of each pulse is expected to rise and fall smoothly with time. However, a careful study has revealed that the edges of mechanically chopped laser light pulses consist of periodic intensity undulations which can be detected with a photo detector. In this paper, it is shown that the intensity undulations in mechanically chopped laser pulses are produced by diffraction of light from the rotating disc, and a detailed explanation is given of the intensity undulations in mechanically chopped laser pulses. An experiment presented in this paper provides an efficient method to capture a one dimensional diffraction profile of light from a straight sharp-edge in the time domain. In addition, the experiment accurately measures wavelengths of three different laser beams from the undulations in mechanically chopped laser light pulses.

  4. Long-term changes in the chemical composition of soil organic matter, depending on fertilization and crop rotation

    NASA Astrophysics Data System (ADS)

    Tammik, Kerttu; Kauer, Karin; Astover, Alar

    2017-04-01

    The objective of this study was to determine whether it is possible to assess the impact of different management practices (crop rotation, fertilization (organic and mineral fertilizers) on the chemical composition of soil organic matter, using Fourier transform infrared spectroscopy (FTIR). The study is based IOSDV long-term (established in 1989) three field crop rotation (potato-wheat-barely) experiment located in Tartu, Estonia. Soil samples (Stagnic Albeluvisol) were collected from the 0-20 cm depth in the autumn of 2015, air dried, sieved to 2 mm and grinded to obtain homogeneous samples. The content of soil organic matter was measured by the dry combustion method in a varioMax CNS elemental analyser (ELEMENTAR, Germany). The samples were analysed using Thermo-Nicolet iS10 Fourier Transform Infrared Spectrophotometer (FT-IR) and OMNIC software. An intense and sharp peak was recorded in the region of Si-O vibrations of clay minerals and polysaccharides in all samples analysed. The volume of the peak correlated with the quantity of fertilizers administered

  5. Chaos in the classical mechanics of bound and quasi-bound HX-4He complexes with X = F, Cl, Br, CN.

    PubMed

    Gamboa, Antonio; Hernández, Henar; Ramilowski, Jordan A; Losada, J C; Benito, R M; Borondo, F; Farrelly, David

    2009-10-01

    The classical dynamics of weakly bound floppy van der Waals complexes have been extensively studied in the past except for the weakest of all, i.e., those involving He atoms. These complexes are of considerable current interest in light of recent experimental work focussed on the study of molecules trapped in small droplets of the quantum solvent (4)He. Despite a number of quantum investigations, details on the dynamics of how quantum solvation occurs remain unclear. In this paper, the classical rotational dynamics of a series of van der Waals complexes, HX-(4)He with X = F, Cl, Br, CN, are studied. In all cases, the ground state dynamics are found to be almost entirely chaotic, in sharp contrast to other floppy complexes, such as HCl-Ar, for which chaos sets in only at relatively high energies. The consequences of this result for quantum solvation are discussed. We also investigate rotationally excited states with J = 1 which, except for HCN-(4)He, are actually resonances that decay by rotational pre-dissociation.

  6. Experimental study of mixing mechanisms in stably stratified Taylor-Couette flow

    NASA Astrophysics Data System (ADS)

    Augier, Pierre; Caulfield, Colm-Cille; Dalziel, Stuart

    2014-11-01

    We consider experimentally the mechanisms of mixing in stably stratified Taylor-Couette (TC) flow in a TC apparatus for which both cylinders can rotate independently. In the case for which only the inner cylinder rotates, centrifugal instability rapidly splits an initially linear density profile into an array of thin nearly homogeneous layers. Shadowgraph, PIV and density profiles measured by a moving conductivity probe allow us to characterise this process and the resulting flow. In particular, we observe turbulent intrusions of mixed fluid propagating relatively slowly around the tank at the interfaces between the layers, leading to a time-dependent variation in the sharpness and turbulent activity at these interfaces, whose period scales with (but is much larger than) the rotation period. Interestingly, the turbulent intrusions are anti-correlated between adjacent interfaces leading to snake-skin-like patterns in the spatio-temporal diagrams of the density profiles. We also explore how the presence of a density stratification modifies end effects at the top and bottom of the cylinders, in both the presence and absence of primary centrifugal instability.

  7. Observation of pulsed hard X-rays/gamma-rays from PSR 1509-58

    NASA Astrophysics Data System (ADS)

    Gunji, S.; Hirayama, M.; Kamae, T.; Miyazaki, S.; Sekimoto, Y.; Takahashi, T.; Tamura, T.; Tanaka, M.; Yamasaki, N.; Yamagami, T.; Nomachi, M.; Murakami, H.; Braga, J.; Neri, J. A.

    1994-06-01

    We observed a young rotation-powered pulsar, PSR 1509-58, in the hard X-ray/gamma-ray or the soft gamma-ray band with a balloon-borne detector in Brazil on 1991 November 19 (UT). With a timing analysis we detected pulsations in the energy band 94-240 keV at the 150.687 ms period determined from radio observations. The pulsating flux is (7.1 +/- 1.7) x 10-4 per sq cm per sec in this band, and the energy spectrum follows a power law with photon index alpha = 1.64 +/- 0.4. The averaged pulse profile shows a broad single peak with a sharp rise and has a duty cycle around 50% or higher: these features are similar to what have been observed in the X-ray band by the Ginga satellite. Based on the data available now, the fraction of energy transformed from rotational energy loss to pulsed/nonpulsed soft gamma-ray radiation is estimated. If the solid angle swept by the pulsed beam is about the same as for the Crab pulsar (PSR 0531+21) and the Vela pulsar (PSR 0833-45), PSR 1509-58 turn out to be an extremely efficient pulsar, converting a large fraction of its rotational energy loss to radiation, as the outer gap model predicts. The observed pulsed spectrum, however, is strong in the soft gamma-ray band, in a sharp contrast to what has been observed in the Vela pulsar, a pulsar expected to be similar PSR 1509-58 in the outer gap model. The fact that the pulse profile remains broad and single-peaked in the soft gamma-ray band is also new for Crab-like pulsars. In these regards, PSR 1509-58 may require some alteration to the standard outer gap model or even a new model for gamma-ray emission in pulsars.

  8. Technique Optimization of Orbital Atherectomy in Calcified Peripheral Lesions of the Lower Extremities: The CONFIRM Series, A Prospective Multicenter Registry

    PubMed Central

    Das, Tony; Mustapha, Jihad; Indes, Jeffrey; Vorhies, Robert; Beasley, Robert; Doshi, Nilesh; Adams, George L

    2014-01-01

    Objectives The purpose of CONFIRM registry series was to evaluate the use of orbital atherectomy (OA) in peripheral lesions of the lower extremities, as well as optimize the technique of OA. Background Methods of treating calcified arteries (historically a strong predictor of treatment failure) have improved significantly over the past decade and now include minimally invasive endovascular treatments, such as OA with unique versatility in modifying calcific lesions above and below-the-knee. Methods Patients (3135) undergoing OA by more than 350 physicians at over 200 US institutions were enrolled on an “all-comers” basis, resulting in registries that provided site-reported patient demographics, ABI, Rutherford classification, co-morbidities, lesion characteristics, plaque morphology, device usage parameters, and procedural outcomes. Results Treatment with OA reduced pre-procedural stenosis from an average of 88–35%. Final residual stenosis after adjunctive treatments, typically low-pressure percutaneous transluminal angioplasty (PTA), averaged 10%. Plaque removal was most effective for severely calcified lesions and least effective for soft plaque. Shorter spin times and smaller crown sizes significantly lowered procedural complications which included slow flow (4.4%), embolism (2.2%), and spasm (6.3%), emphasizing the importance of treatment regimens that focus on plaque modification over maximizing luminal gain. Conclusion The OA technique optimization, which resulted in a change of device usage across the CONFIRM registry series, corresponded to a lower incidence of adverse events irrespective of calcium burden or co-morbidities. © 2013 The Authors. Wiley Periodicals, Inc. PMID:23737432

  9. Long-Term Outcomes After Percutaneous Lower Extremity Arterial Interventions With Atherectomy vs. Balloon Angioplasty - Propensity Score-Matched Registry.

    PubMed

    Janas, Adam; Buszman, Piotr P; Milewski, Krzysztof P; Wiernek, Szymon; Janas, Ksenia; Pruski, Maciej; Wojakowski, Wojciech; Błachut, Aleksandra; Picheta, Wojciech; Buszman, Pawel; Kiesz, Stefan

    2017-02-24

    The impact of endovascular revascularization of the lower extremity arteries with atherectomy (AT) compared with percutaneous transluminal angioplasty (PTA) is still unclear. Therefore, the aim of the study was to compare long-term outcomes after percutaneous PTA and AT in patients requiring endovascular revascularization.Methods and Results:This was a single-center, retrospective registry of obstructive and symptomatic PAD patients who underwent endovascular revascularization. PTA was performed in 215 patients, and AT in 204 (Silver Hawk, EV3, n=125; CSI 360°, n=66; Pathway Medical Technologies, n=13). There were no significant between-group differences in baseline characteristics except for increased CAD, dialysis and CLI prevalence in the PTA group. Following propensity score analysis 131 well-matched pairs were included in analysis. Bail-out stenting was more frequent in the reference group (PTA, 6.1% vs. AT, 0%; P=0.004). At 6- and 12-month follow-up there were no differences in TLR between the groups (PTA, 8.3% vs. AT, 5.3%; P=0.47; and PTA, 16.7% vs. AT, 13.7%; P=0.73, respectively). The difference was in favor of AT at 24-month follow-up (PTA, 29.0% vs. AT, 16.7%; P=0.05). No difference was observed in amputation rate (PTA, 0.7% vs AT, 1.5%; P=0.62). On Kaplan-Meier analysis there were no significant differences between groups in time to TLR, amputation or death. AT was associated with lower risk of TLR, and this should be confirmed in randomized controlled trials.

  10. High-throughput simultaneous analysis of RNA, protein, and lipid biomarkers in heterogeneous tissue samples.

    PubMed

    Reiser, Vladimír; Smith, Ryan C; Xue, Jiyan; Kurtz, Marc M; Liu, Rong; Legrand, Cheryl; He, Xuanmin; Yu, Xiang; Wong, Peggy; Hinchcliffe, John S; Tanen, Michael R; Lazar, Gloria; Zieba, Renata; Ichetovkin, Marina; Chen, Zhu; O'Neill, Edward A; Tanaka, Wesley K; Marton, Matthew J; Liao, Jason; Morris, Mark; Hailman, Eric; Tokiwa, George Y; Plump, Andrew S

    2011-11-01

    With expanding biomarker discovery efforts and increasing costs of drug development, it is critical to maximize the value of mass-limited clinical samples. The main limitation of available methods is the inability to isolate and analyze, from a single sample, molecules requiring incompatible extraction methods. Thus, we developed a novel semiautomated method for tissue processing and tissue milling and division (TMAD). We used a SilverHawk atherectomy catheter to collect atherosclerotic plaques from patients requiring peripheral atherectomy. Tissue preservation by flash freezing was compared with immersion in RNAlater®, and tissue grinding by traditional mortar and pestle was compared with TMAD. Comparators were protein, RNA, and lipid yield and quality. Reproducibility of analyte yield from aliquots of the same tissue sample processed by TMAD was also measured. The quantity and quality of biomarkers extracted from tissue prepared by TMAD was at least as good as that extracted from tissue stored and prepared by traditional means. TMAD enabled parallel analysis of gene expression (quantitative reverse-transcription PCR, microarray), protein composition (ELISA), and lipid content (biochemical assay) from as little as 20 mg of tissue. The mean correlation was r = 0.97 in molecular composition (RNA, protein, or lipid) between aliquots of individual samples generated by TMAD. We also demonstrated that it is feasible to use TMAD in a large-scale clinical study setting. The TMAD methodology described here enables semiautomated, high-throughput sampling of small amounts of heterogeneous tissue specimens by multiple analytical techniques with generally improved quality of recovered biomolecules.

  11. The stability of a thin water layer over a rotating disk revisited

    NASA Astrophysics Data System (ADS)

    Poncet, Sébastien

    2014-08-01

    The flow driven by a rotating disk of a thin fluid layer in a fixed cylindrical casing is studied by direct numerical simulation and experimental flow visualizations. The characteristics of the flow are first briefly discussed but the focus of this work is to understand the transition to the primary instability. The primary bifurcation is 3D and appears as spectacular sharp-cornered polygonal patterns located along the shroud. The stability diagram is established experimentally in a ( Re, G plane, where G is the aspect ratio of the cavity and Re the rotational Reynolds number and confirmed numerically. The number of vortices scales well with the Ekman number based on the water depth, which confirms the existence of a Stewartson layer along the external cylinder. The critical mixed Reynolds number is found to be constant as in other rotating flows involving a shear-layer instability. Hysteresis cycles are observed highlighting the importance of the spin-up and spin-down processes. In some particular cases, a crossflow instability appears under the form of high azimuthal wave number spiral patterns, similar to those observed in a rotor-stator cavity with throughflow and coexists with the polygons. The DNS calculations confirm the experimental results under the flat free surface hypothesis.

  12. Coronary revascularization in Japan. Part 2: comparison of facilities between 1997 and 1999.

    PubMed

    Tsuchihashi, M; Tsutsui, H; Shihara, M; Shigematsu, H; Yamamoto, S; Koike, G; Kono, S; Takeshita, A

    2001-12-01

    A nation-wide survey on the procedures and facilities of coronary revascularization, percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) conducted by the Japanese Coronary Intervention Study (JCIS) group during 1997 revealed that PCI is more often used than CABG and is mainly carried out in low-volume facilities without surgical backup. The present study aimed to investigate the temporal changes in the usage of revascularization therapies and facilities from 1997 to 1999. A questionnaire was mailed in 1998 to the delegates of 1,086 PCI and 582 CABG facilities identified by the previous survey, and 89% of PCIs surveyed and 94% of CABGs surveyed reported back. The number of PCI procedures had increased by 19% from 97,831 to 116,479 and that of CABG procedures also increased by 21% from 16,374 to 19,846. The ratio of PCI to CABG was 5.9 in 1999, showing no significant change from 6.0 in 1997. In parallel, the number of PCI and CABG facilities increased from 888 to 941 and from 442 to 453, respectively. The use of coronary stents and other interventional devices increased during these 2 years. Coronary stents were used regardless of the annual procedural volume of the facilities, whereas other interventional devices, directional and rotational coronary atherectomy, were used mainly in the high-volume laboratories (p<0.01). Beating-heart, off-pump CABG had increased from 2% to 11% of total cases. Continued monitoring of trends in PCI and CABG facilities and procedures will be needed for nation-wide assessment of the use of new technology.

  13. [Normal anatomy and related pathological changes of shoulder on MRI].

    PubMed

    Zhu, Q; Katsuya, N

    2000-04-01

    To describe the normal anatomy and common abnormal changes of rotator cuff impingement and tears and recurrent anterior instability of shoulder joint in MRI pictures. MRI was compared in 285 patients with shoulder diseases and 20 patients with symptomatic shoulder diseases. On oblique coronal image, the supraspinatus presented moderate signal intensity and low signal intensity in its tendon-muscle conjunction ranging from the humeral head to the greater tuberosity. The MRI manifestations of impingement lesion of the rotator cuff were as follows: high signal intensity of tendons, changes of their shapes, retraction of tendon-muscle conjunction, and muscle atrophy with high signal intensity. On T1-weighted axial image, the anterior and posterior glenohumeral labrum, the long head biceps tendon were displayed in low signal intensity. The anterior labrum manifested a sharp triangle contour and the posterior labrum a round one. The whole four muscles of the rotator cuff manifested on oblique sagital image. However, it was of less value in detecting the abnormalities of the rotator cuff and the glenohumeral labrum on sagittal imaging. The sensitivity in demonstrating rotator cuff complete tear was 95% for MRI and 91% for arthrography; the specificity was 88% for MRI and 100% for arthrography. The sensitivity and specificity of MRI were 96% and 75% for detecting glenoid labrum abnormalities, and 78% and 88% for detecting labrum tear in anterior recurrent dislocation of the shoulder. Magnetic resonance imaging with its excellent contrast resolution in multiple anatomic planes allows noninvasive visualization of bone and soft tissues in the rotator cuff and labrum.

  14. MRI artifact reduction and quality improvement in the upper abdomen with PROPELLER and prospective acquisition correction (PACE) technique.

    PubMed

    Hirokawa, Yuusuke; Isoda, Hiroyoshi; Maetani, Yoji S; Arizono, Shigeki; Shimada, Kotaro; Togashi, Kaori

    2008-10-01

    The purpose of this study was to evaluate the effectiveness of the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER [BLADE in the MR systems from Siemens Medical Solutions]) with a respiratory compensation technique for motion correction, image noise reduction, improved sharpness of liver edge, and image quality of the upper abdomen. Twenty healthy adult volunteers with a mean age of 28 years (age range, 23-42 years) underwent upper abdominal MRI with a 1.5-T scanner. For each subject, fat-saturated T2-weighted turbo spin-echo (TSE) sequences with respiratory compensation (prospective acquisition correction [PACE]) were performed with and without the BLADE technique. Ghosting artifact, artifacts except ghosting artifact such as respiratory motion and bowel movement, sharpness of liver edge, image noise, and overall image quality were evaluated visually by three radiologists using a 5-point scale for qualitative analysis. The Wilcoxon's signed rank test was used to determine whether a significant difference existed between images with and without BLADE. A p value less than 0.05 was considered to be statistically significant. In the BLADE images, image artifacts, sharpness of liver edge, image noise, and overall image quality were significantly improved (p < 0.001). With the BLADE technique, T2-weighted TSE images of the upper abdomen could provide reduced image artifacts including ghosting artifact and image noise and provide better image quality.

  15. Seismic constraints on the radial dependence of the internal rotation profiles of six Kepler subgiants and young red giants

    NASA Astrophysics Data System (ADS)

    Deheuvels, S.; Doğan, G.; Goupil, M. J.; Appourchaux, T.; Benomar, O.; Bruntt, H.; Campante, T. L.; Casagrande, L.; Ceillier, T.; Davies, G. R.; De Cat, P.; Fu, J. N.; García, R. A.; Lobel, A.; Mosser, B.; Reese, D. R.; Regulo, C.; Schou, J.; Stahn, T.; Thygesen, A. O.; Yang, X. H.; Chaplin, W. J.; Christensen-Dalsgaard, J.; Eggenberger, P.; Gizon, L.; Mathis, S.; Molenda-Żakowicz, J.; Pinsonneault, M.

    2014-04-01

    Context. We still do not understand which physical mechanisms are responsible for the transport of angular momentum inside stars. The recent detection of mixed modes that contain the clear signature of rotation in the spectra of Kepler subgiants and red giants gives us the opportunity to make progress on this question. Aims: Our aim is to probe the radial dependence of the rotation profiles for a sample of Kepler targets. For this purpose, subgiants and early red giants are particularly interesting targets because their rotational splittings are more sensitive to the rotation outside the deeper core than is the case for their more evolved counterparts. Methods: We first extracted the rotational splittings and frequencies of the modes for six young Kepler red giants. We then performed a seismic modeling of these stars using the evolutionary codes Cesam2k and astec. By using the observed splittings and the rotational kernels of the optimal models, we inverted the internal rotation profiles of the six stars. Results: We obtain estimates of the core rotation rates for these stars, and upper limits to the rotation in their convective envelope. We show that the rotation contrast between the core and the envelope increases during the subgiant branch. Our results also suggest that the core of subgiants spins up with time, while their envelope spins down. For two of the stars, we show that a discontinuous rotation profile with a deep discontinuity reproduces the observed splittings significantly better than a smooth rotation profile. Interestingly, the depths that are found to be most probable for the discontinuities roughly coincide with the location of the H-burning shell, which separates the layers that contract from those that expand. Conclusions: We characterized the differential rotation pattern of six young giants with a range of metallicities, and with both radiative and convective cores on the main sequence. This will bring observational constraints to the scenarios of angular momentum transport in stars. Moreover, if the existence of sharp gradients in the rotation profiles of young red giants is confirmed, it is expected to help in distinguishing between the physical processes that could transport angular momentum in the subgiant and red giant branches. Appendices and Tables 3-9 are available in electronic form at http://www.aanda.org

  16. Rayleigh- and Prandtl-number dependence of the large-scale flow-structure in weakly-rotating turbulent thermal convection

    NASA Astrophysics Data System (ADS)

    Weiss, Stephan; Wei, Ping; Ahlers, Guenter

    2015-11-01

    Turbulent thermal convection under rotation shows a remarkable variety of different flow states. The Nusselt number (Nu) at slow rotation rates (expressed as the dimensionless inverse Rossby number 1/Ro), for example, is not a monotonic function of 1/Ro. Different 1/Ro-ranges can be observed with different slopes ∂Nu / ∂ (1 / Ro) . Some of these ranges are connected by sharp transitions where ∂Nu / ∂ (1 / Ro) changes discontinuously. We investigate different regimes in cylindrical samples of aspect ratio Γ = 1 by measuring temperatures at the sidewall of the sample for various Prandtl numbers in the range 3 < Pr < 35 and Rayleigh numbers in the range of 108 < Ra < 4 ×1011 . From these measurements we deduce changes of the flow structure. We learn about the stability and dynamics of the large-scale circulation (LSC), as well as about its breakdown and the onset of vortex formation close to the top and bottom plate. We shall examine correlations between these measurements and changes in the heat transport. This work was supported by NSF grant DRM11-58514. SW acknowledges support by the Deutsche Forschungsgemeinschaft.

  17. The equilibrium of overpressurized polytropes

    NASA Astrophysics Data System (ADS)

    Huré, J.-M.; Hersant, F.; Nasello, G.

    2018-03-01

    We investigate the impact of an external pressure on the structure of self-gravitating polytropes for axially symmetric ellipsoids and rings. The confinement of the fluid by photons is accounted for through a boundary condition on the enthalpy H. Equilibrium configurations are determined numerically from a generalized `self-consistent-field' method. The new algorithm incorporates an intraloop re-scaling operator R(H), which is essential for both convergence and getting self-normalized solutions. The main control parameter is the external-to-core enthalpy ratio. In the case of uniform rotation rate and uniform surrounding pressure, we compute the mass, the volume, the rotation rate and the maximum enthalpy. This is repeated for a few polytropic indices, n. For a given axial ratio, overpressurization globally increases all output quantities, and this is more pronounced for large n. Density profiles are flatter than in the absence of an external pressure. When the control parameter asymptotically tends to unity, the fluid converges towards the incompressible solution, whatever the index, but becomes geometrically singular. Equilibrium sequences, obtained by varying the axial ratio, are built. States of critical rotation are greatly exceeded or even disappear. The same trends are observed with differential rotation. Finally, the typical response to a photon point source is presented. Strong irradiation favours sharp edges. Applications concern star-forming regions and matter orbiting young stars and black holes.

  18. An All-Dielectric Coaxial Waveguide.

    PubMed

    Ibanescu; Fink; Fan; Thomas; Joannopoulos

    2000-07-21

    An all-dielectric coaxial waveguide that can overcome problems of polarization rotation and pulse broadening in the transmission of optical light is presented here. It consists of a coaxial waveguiding region with a low index of refraction, bounded by two cylindrical, dielectric, multilayer, omnidirectional reflecting mirrors. The waveguide can be designed to support a single mode whose properties are very similar to the unique transverse electromagnetic mode of a traditional metallic coaxial cable. The new mode has radial symmetry and a point of zero dispersion. Moreover, because the light is not confined by total internal reflection, the waveguide can guide light around very sharp corners.

  19. Rotational Spectroscopy Unveils Eleven Conformers of Adrenaline

    NASA Astrophysics Data System (ADS)

    Cabezas, C.; Cortijo, V.; Mata, S.; Lopez, J. C.; Alonso, J. L.

    2013-06-01

    Recent improvements in our LA-MB-FTMW instrumentation have allowed the characterization of eleven and eight conformers for the neurotransmitters adrenaline and noradrenaline respectively. The observation of this rich conformational behavior is in accordance with the recent observation of seven conformers for dopamine and in sharp contrast with the conformational reduction proposed for catecholamines. C. Cabezas, I. Peña, J. C. López, J. L. Alonso J. Phys. Chem. Lett. 2013, 4, 486. H. Mitsuda, M. Miyazaki, I. B. Nielsen, P. Carcabal,C. Dedonder, C. Jouvet, S. Ishiuchi, M. Fujii J. Phys. Chem. Lett. 2010, 1, 1130.

  20. SDSS-IV MaNGA: stellar angular momentum of about 2300 galaxies: unveiling the bimodality of massive galaxy properties

    NASA Astrophysics Data System (ADS)

    Graham, Mark T.; Cappellari, Michele; Li, Hongyu; Mao, Shude; Bershady, Matthew A.; Bizyaev, Dmitry; Brinkmann, Jonathan; Brownstein, Joel R.; Bundy, Kevin; Drory, Niv; Law, David R.; Pan, Kaike; Thomas, Daniel; Wake, David A.; Weijmans, Anne-Marie; Westfall, Kyle B.; Yan, Renbin

    2018-07-01

    We measure λ _{R_e}, a proxy for galaxy specific stellar angular momentum within one effective radius, and the ellipticity, ɛ, for about 2300 galaxies of all morphological types observed with integral field spectroscopy as part of the Mapping Nearby Galaxies at Apache Point Observatory survey, the largest such sample to date. We use the (λ _{R_e}, ɛ ) diagram to separate early-type galaxies into fast and slow rotators. We also visually classify each galaxy according to its optical morphology and two-dimensional stellar velocity field. Comparing these classifications to quantitative λ _{R_e} measurements reveals tight relationships between angular momentum and galaxy structure. In order to account for atmospheric seeing, we use realistic models of galaxy kinematics to derive a general approximate analytic correction for λ _{R_e}. Thanks to the size of the sample and the large number of massive galaxies, we unambiguously detect a clear bimodality in the (λ _{R_e}, ɛ ) diagram which may result from fundamental differences in galaxy assembly history. There is a sharp secondary density peak inside the region of the diagram with low λ _{R_e} and ɛ < 0.4, previously suggested as the definition for slow rotators. Most of these galaxies are visually classified as non-regular rotators and have high velocity dispersion. The intrinsic bimodality must be stronger, as it tends to be smoothed by noise and inclination. The large sample of slow rotators allows us for the first time to unveil a secondary peak at ±90° in their distribution of the misalignments between the photometric and kinematic position angles. We confirm that genuine slow rotators start appearing above M ≥ 2 × 1011 M⊙ where a significant number of high-mass fast rotators also exist.

  1. SDSS-IV MaNGA: Stellar angular momentum of about 2300 galaxies: unveiling the bimodality of massive galaxy properties

    NASA Astrophysics Data System (ADS)

    Graham, Mark T.; Cappellari, Michele; Li, Hongyu; Mao, Shude; Bershady, Matthew; Bizyaev, Dmitry; Brinkmann, Jonathan; Brownstein, Joel R.; Bundy, Kevin; Drory, Niv; Law, David R.; Pan, Kaike; Thomas, Daniel; Wake, David A.; Weijmans, Anne-Marie; Westfall, Kyle B.; Yan, Renbin

    2018-03-01

    We measure λ _{R_e}, a proxy for galaxy specific stellar angular momentum within one effective radius, and the ellipticity, ɛ, for about 2300 galaxies of all morphological types observed with integral field spectroscopy as part of the MaNGA survey, the largest such sample to date. We use the (λ _{R_e}, ɛ ) diagram to separate early-type galaxies into fast and slow rotators. We also visually classify each galaxy according to its optical morphology and two-dimensional stellar velocity field. Comparing these classifications to quantitative λ _{R_e} measurements reveals tight relationships between angular momentum and galaxy structure. In order to account for atmospheric seeing, we use realistic models of galaxy kinematics to derive a general approximate analytic correction for λ _{R_e}. Thanks to the size of the sample and the large number of massive galaxies, we unambiguously detect a clear bimodality in the (λ _{R_e}, ɛ ) diagram which may result from fundamental differences in galaxy assembly history. There is a sharp secondary density peak inside the region of the diagram with low λ _{R_e} and ɛ < 0.4, previously suggested as the definition for slow rotators. Most of these galaxies are visually classified as non-regular rotators and have high velocity dispersion. The intrinsic bimodality must be stronger, as it tends to be smoothed by noise and inclination. The large sample of slow rotators allows us for the first time to unveil a secondary peak at ±90○ in their distribution of the misalignments between the photometric and kinematic position angles. We confirm that genuine slow rotators start appearing above M ≥ 2 × 1011M⊙ where a significant number of high-mass fast rotators also exist.

  2. Non-resonant divertors for stellarators

    NASA Astrophysics Data System (ADS)

    Boozer, Allen; Punjabi, Alkesh

    2017-10-01

    The outermost confining magnetic surface in optimized stellarators has sharp edges, which resemble tokamak X-points. The plasma cross section has an even number of edges at the beginning but an odd number half way through the period. Magnetic field lines cannot cross sharp edges, but stellarator edges have a finite length and do not determine the rotational transform on the outermost confining surface. Just outside the last confining surface, surfaces formed by magnetic field lines have splits containing two adjacent magnetic flux tubes: one with entering and the other with an equal existing flux to the walls. The splits become wider with distance outside the outermost confining surface. These flux tubes form natural non-resonant stellarator divertors, which we are studying using maps. This work is supported by the US DOE Grants DE-FG02-95ER54333 to Columbia University and DE-FG02-01ER54624 and DE-FG02-04ER54793 to Hampton University and used resources of the NERSC, supported by the Office of Science, US DOE, under Contract No. DE-AC02-.

  3. Effects of Phytoplankton Growth Phase on Delayed Settling Behavior of Marine Snow Aggregates at Sharp Density Transitions

    NASA Astrophysics Data System (ADS)

    Proctor, K. W.; Montgomery, Q. W.; Prairie, J. C.

    2016-02-01

    Marine snow aggregates play a fundamental role in the marine carbon cycle. Since marine snow aggregates are larger and thus sink faster than individual phytoplankton, aggregates often dominate carbon flux. Previous studies have shown that marine snow aggregates will significantly decrease their settling velocity when passing through sharp density transitions within the ocean, a phenomenon defined as delayed settling. Given the importance of aggregate settling to carbon export, these small-scale changes in aggregate settling dynamics may have significant impacts on the efficiency of the biological pump. However, there is still a lack of knowledge about how different physical properties of aggregates can affect this delayed settling. In this study, we investigated the effect of phytoplankton growth phase on delayed settling behavior. Using phytoplankton cultures stopped at four different growth phases, we formed marine snow aggregates in the laboratory in rotating cylindrical tanks. We then observed individual aggregates as they settled through a stratified tank. We will present data which illustrates that aggregates experience greatly reduced settling rates when passing through sharp density gradients and that the growth phase of the phytoplankton used to form these aggregates has a significant effect on this delayed settling behavior. A thorough understanding of the impact of phytoplankton growth phase on the delayed settling behavior of marine snow will offer insight into the way phytoplankton growth phase may influence the efficiency of the biological pump, carbon flux, and the carbon cycle as a whole.

  4. Reynolds stress and heat flux in spherical shell convection

    NASA Astrophysics Data System (ADS)

    Käpylä, P. J.; Mantere, M. J.; Guerrero, G.; Brandenburg, A.; Chatterjee, P.

    2011-07-01

    Context. Turbulent fluxes of angular momentum and enthalpy or heat due to rotationally affected convection play a key role in determining differential rotation of stars. Their dependence on latitude and depth has been determined in the past from convection simulations in Cartesian or spherical simulations. Here we perform a systematic comparison between the two geometries as a function of the rotation rate. Aims: Here we want to extend the earlier studies by using spherical wedges to obtain turbulent angular momentum and heat transport as functions of the rotation rate from stratified convection. We compare results from spherical and Cartesian models in the same parameter regime in order to study whether restricted geometry introduces artefacts into the results. In particular, we want to clarify whether the sharp equatorial profile of the horizontal Reynolds stress found in earlier Cartesian models is also reproduced in spherical geometry. Methods: We employ direct numerical simulations of turbulent convection in spherical and Cartesian geometries. In order to alleviate the computational cost in the spherical runs, and to reach as high spatial resolution as possible, we model only parts of the latitude and longitude. The rotational influence, measured by the Coriolis number or inverse Rossby number, is varied from zero to roughly seven, which is the regime that is likely to be realised in the solar convection zone. Cartesian simulations are performed in overlapping parameter regimes. Results: For slow rotation we find that the radial and latitudinal turbulent angular momentum fluxes are directed inward and equatorward, respectively. In the rapid rotation regime the radial flux changes sign in accordance with earlier numerical results, but in contradiction with theory. The latitudinal flux remains mostly equatorward and develops a maximum close to the equator. In Cartesian simulations this peak can be explained by the strong "banana cells". Their effect in the spherical case does not appear to be as large. The latitudinal heat flux is mostly equatorward for slow rotation but changes sign for rapid rotation. Longitudinal heat flux is always in the retrograde direction. The rotation profiles vary from anti-solar (slow equator) for slow and intermediate rotation to solar-like (fast equator) for rapid rotation. The solar-like profiles are dominated by the Taylor-Proudman balance. Movies and Appendix A are available in electronic form at http://www.aanda.org

  5. On the correlation between ‘non-local’ effects and intrinsic rotation reversals in Alcator C-Mod

    NASA Astrophysics Data System (ADS)

    Rodriguez-Fernandez, P.; Rice, J. E.; Cao, N. M.; Creely, A. J.; Howard, N. T.; Hubbard, A. E.; Irby, J. H.; White, A. E.

    2017-07-01

    Contemporary predictive models for heat and particle transport in tokamak plasmas are based on the assumption that local fluxes can be described in terms of local plasma parameters, where electromagnetic drift-wave-type turbulence is driven by local gradients and results in cross-field transport. The question of whether or not transport could be dominated by non-local terms in certain circumstances is essential for our understanding of transport in magnetically confined plasmas, and critical for developing predictive models for future tokamaks, such as ITER. Perturbative transport experiments using cold-pulse injections at low density seem to challenge the local closure of anomalous transport: a rapid temperature increase in the core of the plasma following a sharp edge cooling is widely observed in tokamaks and helical devices. Past work in Ohmic plasmas in Alcator C-Mod and in ECH plasmas in KSTAR found that the temperature inversions disappear at higher densities, above the intrinsic toroidal rotation reversal density. These observations suggested that the so-called ‘non-local’ heat transport effects were related to the intrinsic rotation reversal, and therefore to changes in momentum transport. In this work, new experiments and analysis at Alcator C-Mod show that intrinsic rotation reversals and disappearance of temperature inversions are not concomitant in Ohmic plasmas at high plasma current and in ICRH L-modes. This new data set shows that the correlation between transient temperature inversions and intrinsic rotation reversals is not universal, suggesting that ‘non-local’ heat transport and momentum transport effects may be affected by different physical mechanisms.

  6. Spectral Deconvolution of the 6196 and 6614 Å Diffuse Interstellar Bands Supports a Common-carrier Origin

    NASA Astrophysics Data System (ADS)

    Bernstein, L. S.; Shroll, R. M.; Galazutdinov, G. A.; Beletsky, Y.

    2018-06-01

    We explore the common-carrier hypothesis for the 6196 and 6614 Å diffuse interstellar bands (DIBs). The observed DIB spectra are sharpened using a spectral deconvolution algorithm. This reveals finer spectral features that provide tighter constraints on candidate carriers. We analyze a deconvolved λ6614 DIB spectrum and derive spectroscopic constants that are then used to model the λ6196 spectra. The common-carrier spectroscopic constants enable quantitative fits to the contrasting λ6196 and λ6614 spectra from two sightlines. Highlights of our analysis include (1) sharp cutoffs for the maximum values of the rotational quantum numbers, J max = K max, (2) the λ6614 DIB consisting of a doublet and a red-tail component arising from different carriers, (3) the λ6614 doublet and λ6196 DIBs sharing a common carrier, (4) the contrasting shapes of the λ6614 doublet and λ6196 DIBs arising from different vibration–rotation Coriolis coupling constants that originate from transitions from a common ground state to different upper electronic state degenerate vibrational levels, and (5) the different widths of the two DIBs arising from different effective rotational temperatures associated with principal rotational axes that are parallel and perpendicular to the highest-order symmetry axis. The analysis results suggest a puckered oblate symmetric top carrier with a dipole moment aligned with the highest-order symmetry axis. An example candidate carrier consistent with these specifications is corannulene (C20H10), or one of its symmetric ionic or dehydrogenated forms, whose rotational constants are comparable to those obtained from spectral modeling of the DIB profiles.

  7. Paleomagnetism of the Chinle and Kayenta Formations, New Mexico and Arizona

    NASA Astrophysics Data System (ADS)

    Bazard, David R.; Butler, Robert F.

    1991-06-01

    Paleomagnetic data were obtained from 22 sites (6-10 samples/site) in the Upper Shale Member of the Chinle Formation, 43 sites in the Owl Rock Member of the Chinle Formation, and 35 sites in the Kayenta Formation. Thermal demagnetization and data analyses indicate that within-site dispersion is an important criterion for selecting sites which retain a high unblocking temperature characteristic remanent magnetization (ChRM). Site-mean directions define at least four antipodal polarity zones within each member/formation, suggesting the ChRM was acquired soon after deposition. Fifteen site-mean virtual geomagnetic poles (VGPs) from the Upper Shale Member of the Chinle Formation yield an early Norian paleomagnetic pole position of 57.4°N, 87.8°E (K = 60, A95 = 5.0°). Eighteen site-mean VGPs from the Owl Rock Member of the Chinle Formation yield a middle Norian paleomagnetic pole position of 56.5°N, 66.4°E (K = 183, A95 = 2.6°). Twenty-three site-mean VGPs from the Kayenta Formation yield a Pliensbachian pole position of 59.0°N, 66.6°E (K = 155, A95 = 2.4°). Combined with paleomagnetic poles from the Moenave Formation and the Shinarump Member of the Chinle Formation, these data record ˜30 m.y. of North American apparent polar wander (APW) within a regional stratigraphic succession. During the Camian and Norian stages of the Late Triassic, Chinle poles progress westward. During the Hettangian through Pliensbachian stages of the Early Jurassic, the pattern of APW changed to an eastward progression. Even after correction for 4° clockwise rotation of the Colorado Plateau, a sharp comer in the APW path (J1 cusp) is resolved near the pole from the Hettangian/Sinemurian (˜200 Ma) Moenave Formation (59.4°N, 59.2°E). Amongst other implications, the sharp change in the APW path at the J1 cusp implies an abrupt change from counterclockwise rotation of Pangea prior to 200 Ma to clockwise rotation thereafter.

  8. Coronary Perforation Complicating Percutaneous Coronary Intervention in Patients With a History of Coronary Artery Bypass Surgery: An Analysis of 309 Perforation Cases From the British Cardiovascular Intervention Society Database.

    PubMed

    Kinnaird, Tim; Anderson, Richard; Ossei-Gerning, Nick; Cockburn, James; Sirker, Alex; Ludman, Peter; de Belder, Mark; Johnson, Thomas W; Copt, Samuel; Zaman, Azfar; Mamas, Mamas A

    2017-09-01

    The evidence base for coronary perforation (CP) occurring during percutaneous coronary intervention in patients with a history of coronary artery bypass surgery (PCI-CABG) is limited and the long-term effects unclear. Using a national PCI database, the incidence, predictors, and outcomes of CP during PCI-CABG were defined. Data were analyzed on all PCI-CABG procedures performed in England and Wales between 2005 and 2013. Multivariate logistic regressions and propensity scores were used to identify predictors of CP and its association with outcomes. During the study period, 309 CPs were recorded during 59 644 PCI-CABG procedures with the incidence rising from 0.32% in 2005 to 0.68% in 2013 ( P <0.001 for trend). Independent associates of perforation in native vessels included age, chronic occlusive disease intervention, rotational atherectomy use, number of stents, hypertension, and female sex. In graft PCI, predictors of perforation were history of stroke, New York Heart Association class, and number of stents used. In-hospital clinical complications including Q-wave myocardial infarction (2.9% versus 0.2%; P <0.001), major bleeding (14.0% versus 0.9%; P <0.001), blood transfusion (3.7% versus 0.2%; P <0.001), and death (10.0% versus 1.1%; P <0.001) were more frequent in patients with CP. A continued excess mortality occurred after perforation, with an odds ratio for 12-month mortality of 1.35 for perforation survivors compared with matched nonperforation survivors without a CP ( P <0.0001). CP is an infrequent event during PCI-CABG but is closely associated with adverse clinical outcomes. A legacy effect of perforation on 12-month mortality was observed. © 2017 American Heart Association, Inc.

  9. Feasibility and efficacy of the 2.5 L and 3.8 L impella percutaneous left ventricular support device during high-risk, percutaneous coronary intervention in patients with severe aortic stenosis.

    PubMed

    Spiro, Jon; Venugopal, Vinod; Raja, Yogesh; Ludman, Peter F; Townend, Jonathan N; Doshi, Sagar N

    2015-05-01

    Assessment of the feasibility and outcomes of the 2.5 L and 3.8 L Impella cardiac pump in patients with severe aortic stenosis (AS) and left ventricular impairment undergoing percutaneous revascularization (PCI) with or without balloon aortic valvuloplasty (BAV). We reviewed the clinical and procedural findings from a consecutive series of unselected patients with severe AS who underwent PCI during Impella support. In addition, we describe novel "balloon-assist" techniques that allowed implantation of Impella into the left ventricle (LV) when initial unassisted attempts failed. Five patients with severe AS were identified (four males, age 78.2 years, aortic valve area (AVA) 0.6 cm(2) , left ventricular ejection fraction (LVEF) 24 ± 5%, mean Society of Thoracic Surgeons (STS) mortality 11% (range 3-17%)). The Impella catheter traversed the aortic valve (AV) unassisted in only one patient, with four cases requiring balloon-assist techniques. All patients underwent planned revascularisation; mean procedure time 177 min (range 135-252 min), mean number of stents 3.4 (range 1-8), with three patients requiring rotational atherectomy. All procedures were well tolerated, with absence of arrhythmia, hypotension, pulmonary edema, stroke, or myocardial infarction. One patient died 48 hr post-PCI of multi-organ failure. The four remaining patients were well at 30 days. Implantation of the 2.5 and 3.8 L Impella appears feasible in patients with severe AS and left ventricle (LV) impairment. A balloon-assist technique may be used to facilitate device implantation when initial unassisted attempts fail. Improved hemodynamic stability may enhance the tolerability of lengthy and complex procedures. © 2014 Wiley Periodicals, Inc.

  10. VizieR Online Data Catalog: Detection of Kepler multiple M-star systems (Rappaport+, 2014)

    NASA Astrophysics Data System (ADS)

    Rappaport, S.; Swift, J.; Levine, A.; Joss, M.; Sanchis-Ojeda, R.; Barclay, T.; Still, M.; Handler, G.; Olah, K.; Muirhead, P. S.; Huber, D.; Vida, K.

    2017-07-01

    In all, we find 297 of the 3897 targets exhibit the requisite significant Fourier transform (FT) signal comprising a base frequency plus its harmonic, with the base frequency exceeding 0.5 cycles/day (i.e., Prot<2 days). We believe that the majority of these periodicities are likely to be due to stellar rotation manifested via starspots, but a significant number may be due to planet transits and binary eclipses. The individual FTs for these systems were further examined to eliminate those which were clearly not due to rotating starspots. In all cases we folded the data modulo the detected fundamental period, and were readily able to rule out cases due to transiting planets since their well-known sharp, relatively rectangular dipping profiles are characteristic. Of course, we also checked the KOI list for matches. Any of the objects that appear in the Kepler eclipsing binary ("EB") star catalog (e.g., Matijevic et al. 2012AJ....143..123M) were likewise eliminated. (2 data files).

  11. Thermal Transport in Nd-doped CeCoIn5

    NASA Astrophysics Data System (ADS)

    Kim, Duk Y.; Lin, Shi-Zeng; Weickert, Franziska; Rosa, P. F. S.; Bauer, Eric D.; Ronning, Filip; Thompson, J. D.; Movshovich, Roman

    Heavy-fermion superconductor CeCoIn5 shows spin-density-wave (SDW) magnetic order in its superconducting state when a high magnetic field is applied. In this Q-phase, the antiferromagnetic order has a single ordering wave vector, and switches its orientation very sharply as magnetic field is rotated within the ab -plane around the [100] (anti-nodal) direction. This hypersensitivity induces a sharp jump of the thermal conductivity. Recently, the SDW with the same ordering wave vector was observed in Nd-doped CeCoIn5 in zero magnetic field. We have measured the thermal conductivity of 5% Nd-doped CeCoIn5 in the magnetic field rotating within the ab -plane. The anisotropy is significantly smaller in the doped material, and the switching transition is much broader. The superconducting transition near Hc 2 is first order, as for the pure CeCoIn5, which indicates the Pauli limited superconductivity. We gratefully acknowledge the support of the U.S. Department of Energy through the LANL/LDRD Program.

  12. Optimizing binary phase and amplitude filters for PCE, SNR, and discrimination

    NASA Technical Reports Server (NTRS)

    Downie, John D.

    1992-01-01

    Binary phase-only filters (BPOFs) have generated much study because of their implementation on currently available spatial light modulator devices. On polarization-rotating devices such as the magneto-optic spatial light modulator (SLM), it is also possible to encode binary amplitude information into two SLM transmission states, in addition to the binary phase information. This is done by varying the rotation angle of the polarization analyzer following the SLM in the optical train. Through this parameter, a continuum of filters may be designed that span the space of binary phase and amplitude filters (BPAFs) between BPOFs and binary amplitude filters. In this study, we investigate the design of optimal BPAFs for the key correlation characteristics of peak sharpness (through the peak-to-correlation energy (PCE) metric), signal-to-noise ratio (SNR), and discrimination between in-class and out-of-class images. We present simulation results illustrating improvements obtained over conventional BPOFs, and trade-offs between the different performance criteria in terms of the filter design parameter.

  13. Chandler wobble: two more large phase jumps revealed

    NASA Astrophysics Data System (ADS)

    Malkin, Zinovy; Miller, Natalia

    2010-12-01

    Investigations of the anomalies in the Earth rotation, in particular, the polar motion components, play an important role in our understanding of the processes that drive changes in the Earth's surface, interior, atmosphere, and ocean. This paper is primarily aimed at investigation of the Chandler wobble (CW) at the whole available 163-year interval to search for the major CW amplitude and phase variations. First, the CW signal was extracted from the IERS (International Earth Rotation and Reference Systems Service) Pole coordinates time series using two digital filters: the singular spectrum analysis and Fourier transform. The CW amplitude and phase variations were examined by means of the wavelet transform and Hilbert transform. Results of our analysis have shown that, besides the well-known CW phase jump in the 1920s, two other large phase jumps have been found in the 1850s and 2000s. As in the 1920s, these phase jumps occurred contemporarily with a sharp decrease in the CW amplitude.

  14. Energy Landscape and Transition State of Protein-Protein Association

    NASA Astrophysics Data System (ADS)

    Alsallaq, Ramzi; Zhou, Huan-Xiang

    2006-11-01

    Formation of a stereospecific protein complex is favored by specific interactions between two proteins but disfavored by the loss of translational and rotational freedom. Echoing the protein folding process, we have previously proposed a transition state for protein-protein association. Here we clarify the specification of the transition state by working with two toy models for protein association. The models demonstrate that a sharp transition between the bound state with numerous short-range interactions but restricted translation and rotational freedom and the unbound state with at most a small number of interactions but expanded configurational freedom. This transition sets the outer boundary of the bound state as well as the transition state for association. The energy landscape is funnel-like, with the deep well of the bound state surrounded by a broad shallow basin. This formalism of protein-protein association is applied to four protein-protein complexes, and is found to give accurate predictions for the effects of charge mutations and ionic strength on the association rates.

  15. Preparation of Regular Specimens for Atom Probes

    NASA Technical Reports Server (NTRS)

    Kuhlman, Kim; Wishard, James

    2003-01-01

    A method of preparation of specimens of non-electropolishable materials for analysis by atom probes is being developed as a superior alternative to a prior method. In comparison with the prior method, the present method involves less processing time. Also, whereas the prior method yields irregularly shaped and sized specimens, the present developmental method offers the potential to prepare specimens of regular shape and size. The prior method is called the method of sharp shards because it involves crushing the material of interest and selecting microscopic sharp shards of the material for use as specimens. Each selected shard is oriented with its sharp tip facing away from the tip of a stainless-steel pin and is glued to the tip of the pin by use of silver epoxy. Then the shard is milled by use of a focused ion beam (FIB) to make the shard very thin (relative to its length) and to make its tip sharp enough for atom-probe analysis. The method of sharp shards is extremely time-consuming because the selection of shards must be performed with the help of a microscope, the shards must be positioned on the pins by use of micromanipulators, and the irregularity of size and shape necessitates many hours of FIB milling to sharpen each shard. In the present method, a flat slab of the material of interest (e.g., a polished sample of rock or a coated semiconductor wafer) is mounted in the sample holder of a dicing saw of the type conventionally used to cut individual integrated circuits out of the wafers on which they are fabricated in batches. A saw blade appropriate to the material of interest is selected. The depth of cut and the distance between successive parallel cuts is made such that what is left after the cuts is a series of thin, parallel ridges on a solid base. Then the workpiece is rotated 90 and the pattern of cuts is repeated, leaving behind a square array of square posts on the solid base. The posts can be made regular, long, and thin, as required for samples for atom-probe analysis. Because of their small volume and regularity, the amount of FIB-milling time can be much less than that of the method of sharp shards. Individual posts can be broken off for mounting in a manner similar to that of the method of sharp shards. Alternatively, the posts can be left intact on the base and the base can be cut to a small square (e.g., 3 by 3 mm) suitable for mounting in an atom probe of a type capable of accepting multiple-tip specimens. The advantage of multiple-tip specimens is the possibility of analyzing many tips without the time-consuming interchange of specimens.

  16. Study of polarization properties of fiber-optics probes with use of a binary phase plate.

    PubMed

    Alferov, S V; Khonina, S N; Karpeev, S V

    2014-04-01

    We conduct a theoretical and experimental study of the distribution of the electric field components in the sharp focal domain when rotating a zone plate with a π-phase jump placed in the focused beam. Comparing the theoretical and experimental results for several kinds of near-field probes, an analysis of the polarization sensitivity of different types of metal-coated aperture probes is conducted. It is demonstrated that with increasing diameter of the non-metal-coated tip part there occurs an essential redistribution of sensitivity in favor of the transverse electric field components and an increase of the probe's energy throughput.

  17. Tunable plasmon-induced transparency in plasmonic metamaterial composed of three identical rings

    NASA Astrophysics Data System (ADS)

    Tian, Yuchen; Ding, Pei; Fan, Chunzhen

    2017-10-01

    We numerically investigated the plasmon-induced transparency (PIT) effect in a three-dimensional plasmonic metamaterial composed of three identical rings. It is illustrated that the PIT effect appears as a result of the destructive interference between the electric dipole and the quadrupole resonance mode. By tuning gap distance, radius or rotation angle of the metamaterial, the required transmission spectra with a narrow sharp transparency peak can be realized. In particular, it is found that an on-to-off amplitude modulation of the PIT transparency window can be achieved by moving or rotating the horizontal ring. Two dips move to high frequency and low frequency regions, respectively, in the transmission spectra by moving the horizontal ring, namely, the width of transmission peak becomes larger. With the rotation of horizontal ring, both width and position of transmission peak are kept invariant. Our designed structure achieved a maximum group index of 352 in the visible frequency range, which has a significant slow light effect. Moreover, the PIT effect is explained based on the classical two-oscillator theory, which is in well agreement with the numerical results. It indicates our proposed structure and theoretical analysis may open up avenues for the tunable control of light in highly integrated optical circuits.

  18. Infrared Spectroscopy of the H2/HD/D2-O2 Van Der Waals Complexes

    NASA Astrophysics Data System (ADS)

    Raston, Paul; Bunn, Hayley

    2016-06-01

    Hydrogen is the most abundant element in the universe and oxygen is the third, so understanding the interaction between the two in their different forms is important to understanding astrochemical processes. The interaction between H2 and O2 has been explored in low energy scattering experiments and by far infrared synchrotron spectroscopy of the van der Waals complex. The far infrared spectra suggest a parallel stacked average structure with seven bound rotationally excited states. Here, we present the far infrared spectrum of HD/D2-O2 and the mid infrared spectrum of H2-O2 at 80 K, recorded at the infrared beamline facility of the Australian Synchrotron. We observed 'sharp' peaks in the mid infrared region, corresponding to the end over end rotation of H2-O2, that are comparatively noisier than analogous peaks in the far infrared where the synchrotron light is brightest. The larger reduced mass of HD and D2 compared to H2 is expected to result in more rotational bound states and narrower bands. The latest results in our ongoing efforts to explore this system will be presented. Y. Kalugina, et al., Phys. Chem. Chem. Phys. 14, 16458 (2012) S. Chefdeville et al. Science 341, 1094 (2013) H. Bunn et al. ApJ 799, 65 (2015)

  19. Cole-Davidson dynamics of simple chain models.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dotson, Taylor C.; McCoy, John Dwane; Adolf, Douglas Brian

    2008-10-01

    Rotational relaxation functions of the end-to-end vector of short, freely jointed and freely rotating chains were determined from molecular dynamics simulations. The associated response functions were obtained from the one-sided Fourier transform of the relaxation functions. The Cole-Davidson function was used to fit the response functions with extensive use being made of Cole-Cole plots in the fitting procedure. For the systems studied, the Cole-Davidson function provided remarkably accurate fits [as compared to the transform of the Kohlrausch-Williams-Watts (KWW) function]. The only appreciable deviations from the simulation results were in the high frequency limit and were due to ballistic or freemore » rotation effects. The accuracy of the Cole-Davidson function appears to be the result of the transition in the time domain from stretched exponential behavior at intermediate time to single exponential behavior at long time. Such a transition can be explained in terms of a distribution of relaxation times with a well-defined longest relaxation time. Since the Cole-Davidson distribution has a sharp cutoff in relaxation time (while the KWW function does not), it makes sense that the Cole-Davidson would provide a better frequency-domain description of the associated response function than the KWW function does.« less

  20. White Dwarf Rotation as a Function of Mass and a Dichotomy of Mode Line Widths: Kepler Observations of 27 Pulsating DA White Dwarfs through K2 Campaign 8

    NASA Astrophysics Data System (ADS)

    Hermes, J. J.; Gänsicke, B. T.; Kawaler, Steven D.; Greiss, S.; Tremblay, P.-E.; Gentile Fusillo, N. P.; Raddi, R.; Fanale, S. M.; Bell, Keaton J.; Dennihy, E.; Fuchs, J. T.; Dunlap, B. H.; Clemens, J. C.; Montgomery, M. H.; Winget, D. E.; Chote, P.; Marsh, T. R.; Redfield, S.

    2017-10-01

    We present photometry and spectroscopy for 27 pulsating hydrogen-atmosphere white dwarfs (DAVs; a.k.a. ZZ Ceti stars) observed by the Kepler space telescope up to K2 Campaign 8, an extensive compilation of observations with unprecedented duration (>75 days) and duty cycle (>90%). The space-based photometry reveals pulsation properties previously inaccessible to ground-based observations. We observe a sharp dichotomy in oscillation mode line widths at roughly 800 s, such that white dwarf pulsations with periods exceeding 800 s have substantially broader mode line widths, more reminiscent of a damped harmonic oscillator than a heat-driven pulsator. Extended Kepler coverage also permits extensive mode identification: we identify the spherical degree of 87 out of 201 unique radial orders, providing direct constraints of the rotation period for 20 of these 27 DAVs, more than doubling the number of white dwarfs with rotation periods determined via asteroseismology. We also obtain spectroscopy from 4 m-class telescopes for all DAVs with Kepler photometry. Using these homogeneously analyzed spectra, we estimate the overall mass of all 27 DAVs, which allows us to measure white dwarf rotation as a function of mass, constraining the endpoints of angular momentum in low- and intermediate-mass stars. We find that 0.51-0.73 M ⊙ white dwarfs, which evolved from 1.7-3.0 M ⊙ ZAMS progenitors, have a mean rotation period of 35 hr with a standard deviation of 28 hr, with notable exceptions for higher-mass white dwarfs. Finally, we announce an online repository for our Kepler data and follow-up spectroscopy, which we collect at http://k2wd.org.

  1. SDSS-IV MaNGA: Uncovering the Angular Momentum Content of Central and Satellite Early-type Galaxies

    NASA Astrophysics Data System (ADS)

    Greene, J. E.; Leauthaud, A.; Emsellem, E.; Ge, J.; Aragón-Salamanca, A.; Greco, J.; Lin, Y.-T.; Mao, S.; Masters, K.; Merrifield, M.; More, S.; Okabe, N.; Schneider, D. P.; Thomas, D.; Wake, D. A.; Pan, K.; Bizyaev, D.; Oravetz, D.; Simmons, A.; Yan, R.; van den Bosch, F.

    2018-01-01

    We study 379 central and 159 satellite early-type galaxies with two-dimensional kinematics from the integral-field survey Mapping Nearby Galaxies at APO (MaNGA) to determine how their angular momentum content depends on stellar and halo mass. Using the Yang et al. group catalog, we identify central and satellite galaxies in groups with halo masses in the range {10}12.5 {h}-1 {M}ȯ < {M}200b< {10}15 {h}-1 {M}ȯ . As in previous work, we see a sharp dependence on stellar mass, in the sense that ∼70% of galaxies with stellar mass {M}* > {10}11 {h}-2 {M}ȯ tend to have very little rotation, while nearly all galaxies at lower mass show some net rotation. The ∼30% of high-mass galaxies that have significant rotation do not stand out in other galaxy properties, except for a higher incidence of ionized gas emission. Our data are consistent with recent simulation results suggesting that major merging and gas accretion have more impact on the rotational support of lower-mass galaxies. When carefully matching the stellar mass distributions, we find no residual differences in angular momentum content between satellite and central galaxies at the 20% level. Similarly, at fixed mass, galaxies have consistent rotation properties across a wide range of halo mass. However, we find that errors in classification of central and satellite galaxies with group finders systematically lower differences between satellite and central galaxies at a level that is comparable to current measurement uncertainties. To improve constraints, the impact of group-finding methods will have to be forward-modeled via mock catalogs.

  2. White Dwarf Rotation as a Function of Mass and a Dichotomy of Mode Line Widths: Kepler  Observations of 27 Pulsating DA White Dwarfs through K2 Campaign 8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermes, J. J.; Fanale, S. M.; Dennihy, E.

    We present photometry and spectroscopy for 27 pulsating hydrogen-atmosphere white dwarfs (DAVs; a.k.a. ZZ Ceti stars) observed by the Kepler space telescope up to K2 Campaign 8, an extensive compilation of observations with unprecedented duration (>75 days) and duty cycle (>90%). The space-based photometry reveals pulsation properties previously inaccessible to ground-based observations. We observe a sharp dichotomy in oscillation mode line widths at roughly 800 s, such that white dwarf pulsations with periods exceeding 800 s have substantially broader mode line widths, more reminiscent of a damped harmonic oscillator than a heat-driven pulsator. Extended Kepler coverage also permits extensive modemore » identification: we identify the spherical degree of 87 out of 201 unique radial orders, providing direct constraints of the rotation period for 20 of these 27 DAVs, more than doubling the number of white dwarfs with rotation periods determined via asteroseismology. We also obtain spectroscopy from 4 m-class telescopes for all DAVs with Kepler photometry. Using these homogeneously analyzed spectra, we estimate the overall mass of all 27 DAVs, which allows us to measure white dwarf rotation as a function of mass, constraining the endpoints of angular momentum in low- and intermediate-mass stars. We find that 0.51–0.73 M {sub ⊙} white dwarfs, which evolved from 1.7–3.0 M {sub ⊙} ZAMS progenitors, have a mean rotation period of 35 hr with a standard deviation of 28 hr, with notable exceptions for higher-mass white dwarfs. Finally, we announce an online repository for our Kepler data and follow-up spectroscopy, which we collect at http://k2wd.org.« less

  3. 3D Reconstruction of a Rotating Erupting Prominence

    NASA Technical Reports Server (NTRS)

    Thompson, W. T.; Kliem, B.; Torok, T.

    2011-01-01

    A bright prominence associated with a coronal mass ejection (CME) was seen erupting from the Sun on 9 April 2008. This prominence was tracked by both the Solar Terrestrial Relations Observatory (STEREO) EUVI and COR1 telescopes, and was seen to rotate about the line of sight as it erupted; therefore, the event has been nicknamed the "Cartwheel CME." The threads of the prominence in the core of the CME quite clearly indicate the structure of a weakly to moderately twisted flux rope throughout the field of view, up to heliocentric heights of 4 solar radii. Although the STEREO separation was 48 deg, it was possible to match some sharp features in the later part of the eruption as seen in the 304 Angstrom line in EUVI and in the H alpha-sensitive bandpass of COR1 by both STEREO Ahead and Behind. These features could then be traced out in three dimensional space, and reprojected into a view in which the eruption is directed towards the observer. The reconstructed view shows that the alignment of the prominence to the vertical axis rotates as it rises up to a leading-edge height of approximately equals 2.5 solar radii, and then remains approximately constant. The alignment at 2.5 solar radii differs by about 115 deg. from the original filament orientation inferred from H alpha and EUV data, and the height profile of the rotation, obtained here for the first time, shows that two thirds of the total rotation is reached within approximately equals 0.5 solar radii above the photosphere. These features are well reproduced by numerical simulations of an unstable moderately twisted flux rope embedded in external flux with a relatively strong shear field component.

  4. Two Blades-Up Runs Using the JetStream Navitus Atherectomy Device Achieve Optimal Tissue Debulking of Nonocclusive In-Stent Restenosis: Observations From a Porcine Stent/Balloon Injury Model.

    PubMed

    Shammas, Nicolas W; Aasen, Nicole; Bailey, Lynn; Budrewicz, Jay; Farago, Trent; Jarvis, Gary

    2015-08-01

    To determine the number of runs with blades up (BU) using the JetStream Navitus to achieving optimal debulking in a porcine model of femoropopliteal artery in-stent restenosis (ISR). In this porcine model, 8 limbs were implanted with overlapping nitinol self-expanding stents. ISR was treated initially with 2 blades-down (BD) runs followed by 4 BU runs (BU1 to BU4). Quantitative vascular angiography (QVA) was performed at baseline, after 2 BD runs, and after each BU run. Plaque surface area and percent stenosis within the treated stented segment were measured. Intravascular ultrasound (IVUS) was used to measure minimum lumen area (MLA) and determine IVUS-derived plaque surface area. QVA showed that plaque surface area was significantly reduced between baseline (83.9%±14.8%) and 2 BD (67.7%±17.0%, p=0.005) and BU1 (55.4%±9.0%, p=0.005) runs, and between BU1 and BU2 runs (50.7%±9.7%, p<0.05). Percent stenosis behaved similarly with no further reduction after BU2. There were no further reductions in plaque surface area or percent stenosis with BU 3 and 4 runs (p=0.10). Similarly, IVUS (24 lesions) confirmed optimal results with BU2 runs and no additional gain in MLA or reduction in plaque surface area with BU3 and 4. IVUS confirmed no orbital cutting with JetStream Navitus. There were no stent strut discontinuities on high-resolution radiographs following atherectomy. JetStream Navitus achieved optimal tissue debulking after 2 BD and 2 BU runs with no further statistical gain in debulking after the BU2 run. Operators treating ISR with JetStream Navitus may be advised to limit their debulking to 2 BD and 2 BU runs to achieve optimal debulking. © The Author(s) 2015.

  5. Correlation Between Arterial FDG Uptake and Biomarkers in Peripheral Artery Disease

    PubMed Central

    Myers, Kelly S.; Rudd, James H. F.; Hailman, Eric P.; Bolognese, James A.; Burke, Joanne; Pinto, Cathy Anne; Klimas, Michael; Hargreaves, Richard; Dansky, Hayes M.; Fayad, Zahi A.

    2014-01-01

    OBJECTIVES A prospective, multicenter 18fluorine-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) imaging study was performed to estimate the correlations among arterial FDG uptake and atherosclerotic plaque biomarkers in patients with peripheral artery disease. BACKGROUND Inflammation within atherosclerotic plaques is associated with instability of the plaque and future cardiovascular events. Previous studies have shown that 18F-FDG-PET/CT is able to quantify inflammation within carotid artery atherosclerotic plaques, but no studies to date have investigated this correlation in peripheral arteries with immunohistochemical confirmation. METHODS Thirty patients across 5 study sites underwent 18F-FDG-PET/CT imaging before Silver-Hawk atherectomy (FoxHollow Technologies, Redwood City, California) for symptomatic common or superficial femoral arterial disease. Vascular FDG uptake (expressed as target-to-background ratio) was measured in the carotid arteries and aorta and femoral arteries, including the region of atherectomy. Immunohistochemistry was performed on the excised atherosclerotic plaque extracts, and cluster of differentiation 68 (CD68) level as a measure of macrophage content was determined. Correlations between target-to-background ratio of excised lesions, as well as entire arterial regions, and CD68 levels were determined. Imaging was performed during the 2 weeks before surgery in all cases. RESULTS Twenty-one patients had adequate-quality 18F-FDG-PET/CT peripheral artery images, and 34 plaque specimens were obtained. No significant correlation between lesion target-to-background ratio and CD68 level was observed. CONCLUSIONS There were no significant correlations between CD68 level (as a measure of macrophage content) and FDG uptake in the peripheral arteries in this multicenter study. Differences in lesion extraction technique, lesion size, the degree of inflammation, and imaging coregistration techniques may have been responsible for the failure to observe the strong correlations with vascular FDG uptake observed in previous studies of the carotid artery and in several animal models of atherosclerosis. PMID:22239891

  6. Investigation of the shell stars omicron and theta Per, and of the eclipsing binary beta Lyr

    NASA Technical Reports Server (NTRS)

    Plavec, M.

    1975-01-01

    All three stars showed rather complicated spectra, which require a very detailed spectroscopic analysis. The far UV spectrum of Beta Lyrae is clearly peculiar, with a multitude of emission lines not observed on any other star so far scanned with Copernicus. This made this star at once the most interesting and also, in a sense, easier to study. The other two stars display a spectrum rich in absorption lines, some of them being fairly broad (as expected for photospheric lines of rapidly rotating objects), some sharp. The later were clearly non-photospheric lines. An attempt was made to distinguish the circumstellar from the interstellar components.

  7. Wear of sharp aggregates in a rotating drum

    NASA Astrophysics Data System (ADS)

    Deiros Quintanilla, Ivan; Combe, Gaël; Emeriault, Fabrice; Toni, Jean-Benoît; Voivret, Charles; Ferellec, Jean François

    2017-06-01

    Aggregates constituting ballast layer wear due to the continuous passage of trains and during the necessary maintenance operations of the track. In order to develop efficient solutions for ballasted tracks design and maintenance, a proper knowledge of the degradation laws of ballast grains is needed. In tribology, the amount of wear due to friction when two surfaces are in contact is classically predicted by Archard's equation. However, due to the continuous evolution of grain angularity and roughness, at the macro-scale wear coefficient cannot be assumed to remain constant, but will depend on the state of degradation of the grain surface. In order to adjust the model to this particular case, the Micro-Deval Attrition test is used. The rotating drum is stopped at intermediate stages and the amount of generated fine particles is measured. Thus the curve of mass loss along time is built. These results are then linked to Archard's model using the values of contact forces and relative displacements extracted from discrete element simulations. Finally, a morphology analysis is performed tracking shape and roughness parameters at different stages of degradation using X-ray tomography and a laser profilometer.

  8. Fabrication of Polyhedral Particles from Spherical Colloids and Their Self-Assembly into Rotator Phases**

    PubMed Central

    Vutukuri, Hanumantha Rao; Imhof, Arnout; van Blaaderen, Alfons

    2014-01-01

    Particle shape is a critical parameter that plays an important role in self-assembly, for example, in designing targeted complex structures with desired properties. Over the last decades, an unprecedented range of monodisperse nanoparticle systems with control over the shape of the particles have become available. In contrast, the choice of micrometer-sized colloidal building blocks of particles with flat facets, that is, particles with polygonal shapes, is significantly more limited. This can be attributed to the fact that in contrast to nanoparticles, the larger colloids are significantly harder to synthesize as single crystals. It is now shown that a very simple building block, such as a micrometer-sized polymeric spherical colloidal particle, is already enough to fabricate particles with regularly placed flat facets, including completely polygonal shapes with sharp edges. As an illustration that the yields are high enough for further self-assembly studies, the formation of three-dimensional rotator phases of fluorescently labelled, micrometer-sized, and charged rhombic dodecahedron particles was demonstrated. This method for fabricating polyhedral particles opens a new avenue for designing new materials. PMID:25366869

  9. Walther Nernst, Albert Einstein, Otto Stern, and the Specific Heat of Hydrogen.

    NASA Astrophysics Data System (ADS)

    Gearhart, Clayton

    2007-04-01

    In 1911, the German physical chemist Walther Nernst observed that the new quantum theory might both clarify unresolved problems in the specific heats of gases and shed new light on quantum theory itself. He noted that measurements of the specific heat of hydrogen gas at low temperatures might be particularly informative. Arnold Euken, working in Nernst's laboratory in Berlin, published the first measurements in 1912. They showed a sharp drop, corresponding to the rotational degrees of freedom ``freezing out.'' Nernst also developed a theory in his 1911 paper, in which, remarkably, rotational energies were not quantized. Instead, the specific heat fell off because the gas was in equilibrium with quantized Planck oscillators. Nernst's theory was flawed But Einstein adopted an improved version at the 1911 Solvay Conference, and in 1913, he and Otto Stern published a more detailed treatment, in which they suggested tentatively that Planck's recently introduced zero-point energy might reduce or even eliminate the need to quantize physical systems. This episode points out just how mysterious quantum phenomena seemed early in the 20th century.

  10. Interfacial Symmetry Control of Emergent Ferromagnetism

    NASA Astrophysics Data System (ADS)

    Grutter, Alexander; Borchers, Julie; Kirby, Brian; He, Chunyong; Arenholz, Elke; Vailionis, Arturas; Flint, Charles; Suzuki, Yuri

    Atomically precise complex oxide heterostructures provide model systems for the discovery of new emergent phenomena since their magnetism, structure and electronic properties are strongly coupled. Octahedral tilts and rotations have been shown to alter the magnetic properties of complex oxide heterostructures, but typically induce small, gradual magnetic changes. Here, we demonstrate sharp switching between ferromagnetic and antiferromagnetic order at the emergent ferromagnetic interfaces of CaRuO3/CaMnO3 superlattices. Through synchrotron X-ray diffraction and neutron reflectometry, we show that octahedral distortions in superlattices with an odd number of CaMnO3 unit cells in each layer are symmetry mismatched across the interface. In this case, the rotation symmetry switches across the interface, reducing orbital overlap, suppressing charge transfer from Ru to Mn, and disrupting the interfacial double exchange. This disruption switches half of the interfaces from ferromagnetic to antiferromagnetic and lowers the saturation magnetic of the superlattice from 1.0 to 0.5 μB/interfacial Mn. By targeting a purely interfacial emergent magnetic system, we achieve drastic alterations to the magnetic ground state with extremely small changes in layer thickness.

  11. Tectonic evolution of Gorda Ridge inferred from sidescan sonar images

    USGS Publications Warehouse

    Masson, D.G.; Cacchione, D.A.; Drake, D.E.

    1988-01-01

    Gorda Ridge is the southern segment of the Juan de Fuca Ridge complex, in the north-east Pacific. Along-strike spreading-rate variation on Gorda Ridge and deformation of Gorda Plate are evidence for compression between the Pacific and Gorda Plates. GLORIA sidescan sonographs allow the spreading fabric associated with Gorda Ridge to be mapped in detail. Between 5 and 2 Ma, a pair of propagating rifts re-orientated the northern segment of Gorda Ridge by about 10?? clockwise, accommodating a clockwise shift in Pacific-Juan de Fuca plate motion that occurred around 5 Ma. Deformation of Gorda Plate, associated with southward decreasing spreading rates along southern Gorda Ridge, is accommodated by a combination of clockwise rotation of Gorda Plate crust, coupled with left-lateral motion on the original normal faults of the ocean crust. Segments of Gorda Plate which have rotated by different amounts are separated by narrow deformation zones across which sharp changes in ocean fabric trend are seen. Although minor lateral movement may occur on these NW to WNW structures, no major right-lateral movement, as predicted by previous models, is observed. ?? 1988 Kluwer Academic Publishers.

  12. Occupational safety among dental health-care workers.

    PubMed

    Shimoji, Shigehiro; Ishihama, Kohji; Yamada, Hidefumi; Okayama, Masaki; Yasuda, Kouichi; Shibutani, Tohru; Ogasawara, Tadashi; Miyazawa, Hiroo; Furusawa, Kiyofumi

    2010-01-01

    Compared to other health-care workers, dental health-care workers come in close contact with patients and use a variety of sharp and high-speed rotating instruments. It is important to understand the characteristics of the occupational accidents that occur. We reviewed incident reports from April 1, 2005, to March 31, 2010, at Matsumoto Dental University Hospital. In addition, questionnaires dealing with identification of occupational safety issues, especially splash exposures, were conducted for dentists, dental hygienists, and nurses. Thirty-two occupational injuries were reported during the study period, including 23 sharp instrument injuries (71.9%), 6 splash exposures (18.8%), and 3 others. Of the six splash exposures, only two cases involved potential contamination with blood or other potentially infectious patient material. Of the 66 workers who experienced sharps injuries, 20 workers (30.3%, 20/66) reported them to the hospital work safety team. The questionnaire revealed high incident of splash exposures and conjunctiva exposures: 87.9% (51/58) and 60.3% (35/58) in dentists and 88.6% (39/44) and 61.4% (27/44) in dental hygienists. The compliance rate for routine use of protective eyewear was 60.3% (35/58) for dentists and 34.1% (15/44) for hygienists. Of the presented informational items included in the questionnaire, those that strongly persuaded respondents to use protective eyewear were 'splatters from the patient's mouth contain blood' (90%, 99/110) and 'dental operations at our clinic are performed based only on a questionnaire without serious examinations for HBV, HCV, and HIV' (71.8%, 79/110). The reason of low compliance of protective eyewear among dentists might relate to fine dental procedures. Appropriate information is important for the motive of wearing personal protective equipment, and an early educational program may have a potential to increase compliance with the use of that equipment.

  13. Mount Sharp 'Photobombs' Curiosity

    NASA Image and Video Library

    2018-01-31

    This self-portrait of NASA's Curiosity Mars rover shows the vehicle on Vera Rubin Ridge, which it's been investigating for the past several months. Directly behind the rover is the start of a clay-rich slope scientists are eager to begin exploring. In the coming week, Curiosity will begin to climb this slope. North is on the left and west is on the right, with Gale Crater's rim on the horizon of both edges. Poking up just behind Curiosity's mast is Mount Sharp, photobombing the robot's selfie. Curiosity landed on Mars five years ago with the intention of studying lower Mount Sharp, where it will remain for all of its time on Mars. The mountain's base provides access to layers formed over millions of years. These layers formed in the presence of water -- likely due to a lake or lakes that sat at the bottom of the mountain, which sits inside of Gale Crater. This mosaic was assembled from dozens of images taken by Curiosity's Mars Hands Lens Imager (MAHLI). They were all taken on Jan. 23, 2018, during Sol 1943. The view does not include the rover's arm nor the MAHLI camera itself, except in the miniature scene reflected upside down in the parabolic mirror at the top of the mast. That mirror is part of Curiosity's Chemistry and Camera (ChemCam) instrument. MAHLI appears in the center of the mirror. Wrist motions and turret rotations on the arm allowed MAHLI to acquire the mosaic's component images. The arm was positioned out of the shot in the images, or portions of images, that were used in this mosaic. A full-resolution image is available at https://photojournal.jpl.nasa.gov/catalog/PIA22207

  14. Backbendings of superdeformed bands in 36;40Ar

    NASA Astrophysics Data System (ADS)

    Xiang, Xu-Hui; He, Xiao-Tao

    2018-05-01

    Experimentally observed superdeformed (SD) rotational bands in 36Ar and 40Ar are studied by the cranked shell model (CSM) with the pairing correlations treated by a particle-number-conserving (PNC) method. This is the first time that PNC-CSM calculations have been performed on the light nuclear mass region around A=40. The experimental kinematic moments of inertia J (1) versus rotational frequency are reproduced well. The backbending of the SD band at frequency around ℏω=1.5 MeV in 36Ar is attributed to the sharp rise of the simultaneous alignments of the neutron and proton 1d 5/2[202]5/2 pairs and 1f 7/2[321]3/2 pairs, which is a consequence of the band crossing between the 1d 5/2[202]5/2 and 1f 7/2[321]3/2 configuration states. The gentle upbending at low frequency of the SD band in 40Ar is mainly affected by the alignments of the neutron 1f 7/2[321]3/2 pairs and proton 1d 5/2[202]5/2 pairs. The PNC-CSM calculations show that besides the diagonal parts, the off-diagonal parts of the alignments play an important role in the rotational behavior of the SD bands. Supported by National Natural Science Foundation of China (11775112 and 11275098) and the Priority Academic Program Development of Jiangsu Higher Education Institutions

  15. Review of the Latest Percutaneous Devices in Critical Limb Ischemia.

    PubMed

    Haghighat, Leila; Altin, Sophia Elissa; Attaran, Robert R; Mena-Hurtado, Carlos; Regan, Christopher J

    2018-04-14

    Critical limb ischemia (CLI) is a terminal stage of peripheral arterial disease that, in the absence of intervention, may lead to lower extremity amputation or death. Endovascular interventions have become a first-line approach to the management of CLI and have advanced considerably within the past decade. This review summarizes the types of percutaneous devices and the techniques that are available for the management of CLI and the data supporting their use. These include devices that establish and maintain vessel patency, including percutaneous transluminal angioplasty, drug-coated balloons, bare metal stents, drug-eluting stents, bioresorbable vascular scaffolds, and atherectomy; devices that provide protection from embolization; and, cell-based therapies. Additionally, ongoing trials with important implications for the field are discussed.

  16. Vertical-Axis Rotations Within Columbia River Basalt Flows Define a Sharp Eastern Boundary of the Coast Range Block with Potentially Increased Seismic Risk for Portland, Oregon

    NASA Astrophysics Data System (ADS)

    Hagstrum, J. T.; Wells, R. E.; Evarts, R. C.; Blakely, R. J.; Beeson, M. H.

    2006-12-01

    Paleomagnetic analysis of the Miocene Columbia River Basalt Group (CRBG) in the northern Willamette Valley of Oregon was undertaken as part of a larger mapping and hydrogeologic investigation of the CRBG's internal stratigraphy and structure. Differences in paleomagnetic directions between flows due to geomagnetic reversals and paleosecular variation, in combination with geochemical data, provide the most reliable means of flow identification. In addition, vertical-axis rotations between CRBG sites in the Portland area and sampling localities within the same flow units on the relatively stable Columbia Plateau were calculated. Clockwise rotations for sites within the northern Willamette Valley are remarkably consistent and have a weighted mean of 29°±3° (N=94). Available paleomagnetic data from CRBG sites along the Oregon coast at Cape Lookout (19°±22°, N=4) and Cape Foulweather (29°±18°, N=4) show similar results. East of the Portland Hills fault zone along the Columbia River Gorge, however, clockwise rotations are much less averaging 12°±3° (N=15). North of Portland, the CRBG rotational values drop abruptly from ~29° to 6°±17° (N=3) across an unnamed fault near Woodland, WA, identified using aeromagnetic data; to the south, the values drop from ~29° to 18°±3° (N=6) across the Mt. Angel-Gales Creek fault zone east of Salem, OR. The eastern boundary of the Oregon Coast Range block is thus defined by three offset NW-trending fault segments, with the offsets corresponding to the Portland and Willamette pull-apart basins. North of the Coast Range block's northern boundary, which is roughly coincident with the Columbia River, CRBG rotations also are about half that (15°±3°, N=15) found within the block. Northward movement and clockwise rotation of the Oregon Coast Range block have previously been modeled as decreasing continuously eastward to the Columbia Plateau. Our new paleomagnetic data indicate an abrupt step down of rotational values by half in the vicinity of the Portland metropolitan area, and that the Portland Hills-Clackamas River and other parallel structural zones could be the loci of larger and more dangerous strike-slip earthquakes than previously thought.

  17. An experimental system for the study of active vibration control - Development and modeling

    NASA Astrophysics Data System (ADS)

    Batta, George R.; Chen, Anning

    A modular rotational vibration system designed to facilitate the study of active control of vibrating systems is discussed. The model error associated with four common types of identification problems has been studied. The general multiplicative uncertainty shape for a vibration system is small in low frequencies, large at high frequencies. The frequency-domain error function has sharp peaks near the frequency of each mode. The inability to identify a high-frequency mode causes an increase of uncertainties at all frequencies. Missing a low-frequency mode causes the uncertainties to be much larger at all frequencies than missing a high-frequency mode. Hysteresis causes a small increase of uncertainty at low frequencies, but its overall effect is relatively small.

  18. Nonlinear dynamics of a pulse-coupled neural oscillator model of orientation tuning in the visual cortex

    NASA Astrophysics Data System (ADS)

    Bressloff, P. C.; Bressloff, N. W.

    2000-02-01

    Orientation tuning in a ring of pulse-coupled integrate-and-fire (IF) neurons is analyzed in terms of spontaneous pattern formation. It is shown how the ring bifurcates from a synchronous state to a non-phase-locked state whose spike trains are characterized by quasiperiodic variations of the inter-spike intervals (ISIs) on closed invariant circles. The separation of these invariant circles in phase space results in a localized peak of activity as measured by the time-averaged firing rate of the neurons. This generates a sharp orientation tuning curve that can lock to a slowly rotating, weakly tuned external stimulus. For fast synapses, breakup of the quasiperiodic orbits occurs leading to high spike time variability suggestive of chaos.

  19. Bat noseleaf model: echolocation function, design considerations, and experimental verification.

    PubMed

    Kuc, Roman

    2011-05-01

    This paper describes a possible bat noseleaf echolocation function that improves target elevation resolution. Bats with a protruding noseleaf can rotate the lancet to act as an acoustic mirror that reflects the nostril emission, modeled as a virtual nostril that produces a delayed emission. The cancellation of the nostril and virtual nostril components at a target produces a sharp spectral notch whose frequency location relates to target elevation. This notch can be observed directly from the swept-frequency emission waveform, suggesting cochlear processing capabilities. Physical acoustic principles indicate the design considerations and trade-offs that a bat can accomplish through noseleaf shape and emission characteristics. An experimental model verifies the analysis and exhibits an elevation versus notch frequency sensitivity of approximately 1°/kHz.

  20. Space-variant restoration of images degraded by camera motion blur.

    PubMed

    Sorel, Michal; Flusser, Jan

    2008-02-01

    We examine the problem of restoration from multiple images degraded by camera motion blur. We consider scenes with significant depth variations resulting in space-variant blur. The proposed algorithm can be applied if the camera moves along an arbitrary curve parallel to the image plane, without any rotations. The knowledge of camera trajectory and camera parameters is not necessary. At the input, the user selects a region where depth variations are negligible. The algorithm belongs to the group of variational methods that estimate simultaneously a sharp image and a depth map, based on the minimization of a cost functional. To initialize the minimization, it uses an auxiliary window-based depth estimation algorithm. Feasibility of the algorithm is demonstrated by three experiments with real images.

  1. Ultraviolet Spectroscopy of Asteroid(4) Vesta

    NASA Technical Reports Server (NTRS)

    Li, Jian-Yang; Bodewits, Dennis; Feaga, Lori M.; Landsman, Wayne; A'Hearn, Michael F.; Mutchler, Max J.; Russell, Christopher T.; McFadden, Lucy A.; Raymond, Carol A.

    2011-01-01

    We report a comprehensive review of the UV-visible spectrum and rotational lightcurve of Vesta combining new observations by Hubble Space Telescope and Swift with archival International Ultraviolet Explorer observations. The geometric albedos of Vesta from 220 nm to 953 nm arc derived by carefully comparing these observations from various instruments at different times and observing geometries. Vesta has a rotationally averaged geometric albedo of 0.09 at 250 nm, 0.14 at 300 nm, 0.26 at 373 nm, 0.38 at 673 nm, and 0.30 at 950 nm. The linear spectral slope in the ultraviolet displays a sharp minimum ncar sub-Earth longitude of 20deg, and maximum in the eastern hemisphere. This is completely consistent with the distribution of the spectral slope in the visible wavelength. The uncertainty of the measurement in the ultraviolet is approx.20%, and in the visible wavelengths better than 10%. The amplitude of Vesta's rotational lightcurves is approx.10% throughout the range of wavelengths we observed, but is smaller at 950 nm (approx.6%) ncar the 1-micron mafic band center. Contrary to earlier reports, we found no evidence for any difference between the phasing of the ultraviolet and visible/ncar-infrared lightcurves with respect to sub-Earth longitude. Vesta's average spectrum between 220 and 950 nm can well be described by measured reflectance spectra of fine particle howardite-like materials of basaltic achondrite meteorites. Combining this with the in-phase behavior of the ultraviolet, visible. and ncar-infrared lightcurves, and the spectral slopes with respect to the rotational phase, we conclude that there is no global ultraviolet/visible reversal on Vesta. Consequently, this implies lack of global space weathering on Vesta. Keyword,: Asteroid Vesta; Spectrophotometry; Spectroscopy; Ultraviolet observations; Hubble Space Telescope observations

  2. A Small Fullerene (C{sub 24}) may be the Carrier of the 11.2 μ m Unidentified Infrared Band

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bernstein, L. S.; Shroll, R. M.; Lynch, D. K.

    2017-02-20

    We analyze the spectrum of the 11.2 μ m unidentified infrared band (UIR) from NGC 7027 and identify a small fullerene (C{sub 24}) as a plausible carrier. The blurring effects of lifetime and vibrational anharmonicity broadening obscure the narrower, intrinsic spectral profiles of the UIR band carriers. We use a spectral deconvolution algorithm to remove the blurring, in order to retrieve the intrinsic profile of the UIR band. The shape of the intrinsic profile—a sharp blue peak and an extended red tail—suggests that the UIR band originates from a molecular vibration–rotation band with a blue band head. The fractional areamore » of the band-head feature indicates a spheroidal molecule, implying a nonpolar molecule and precluding rotational emission. Its rotational temperature should be well approximated by that measured for nonpolar molecular hydrogen, ∼825 K for NGC 7027. Using this temperature, and the inferred spherical symmetry, we perform a spectral fit to the intrinsic profile, which results in a rotational constant implying C{sub 24} as the carrier. We show that the spectroscopic parameters derived for NGC 7027 are consistent with the 11.2 μ m UIR bands observed for other objects. We present density functional theory (DFT) calculations for the frequencies and infrared intensities of C{sub 24}. The DFT results are used to predict a spectral energy distribution (SED) originating from absorption of a 5 eV photon, and characterized by an effective vibrational temperature of 930 K. The C{sub 24} SED is consistent with the entire UIR spectrum and is the dominant contributor to the 11.2 and 12.7 μ m bands.« less

  3. Molecular dynamics simulations of quinoline in the liquid phase.

    PubMed

    Soetens, Jean-Christophe; Ahmad, Norariza; Adnan, Rohana; Millot, Claude

    2012-05-17

    Molecular dynamics simulations of liquid quinoline have been performed at experimental densities corresponding to the temperature range 276-320 K. The intermolecular potential is a simple effective two-body potential between rigid molecules having 17 atomic Lennard-Jones and electrostatic Coulomb interaction sites. The vaporization enthalpy is overestimated by 8-9% with respect to the experimental value. The translational diffusion coefficient exhibits a small non-Arrhenius behavior with a change in temperatures near 290 and 303 K. The rotational diffusion tensor is rotated around the z axis perpendicular to the molecular plane by an angle of 4-6° with respect to the frame of reference defined by the principal axes of inertia. The rotational diffusion tensor presents a significant anisotropy with D(rot,y)/D(rot,x) ≃ 0.6-0.5 and D(rot,z)/D(rot,x) ≃ 1.6-1.3 between 276 and 320 K when the x axis is defined as the long molecular axis and the y axis is situated nearly along the central C-C bond. The rotational diffusion coefficients, the reorientational correlation times of the C-H vectors, and the T1(13)C NMR relaxation times present a non-Arrhenius break around 288-290 K in agreement with several experimental results. In addition, a non-Arrhenius break can also be observed at 303 K for these properties. It has been found that the structure evolves smoothly in the studied temperature range. Center of mass-center of mass and atom-atom radial distribution functions show a monotonous evolution with temperature. Various types of first-neighbor dimers have been defined, and their population analysis has revealed a continuous monotonous evolution with temperature. Thus, the non-Arrhenius behavior observed for translational and rotational diffusion is correlated with the monotonous evolution of the population of first-neighbor dimers at a microscopic level and not with a sharp structural transition.

  4. Faraday effect on the Rb D{sub 1} line in a cell with a thickness of half the wavelength of light

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sargsyan, A., E-mail: sarmeno@mail.ru, E-mail: sargsyanarmen85@gmail.com; Pashayan-Leroy, Y.; Leroy, C.

    2016-09-15

    The rotation of the radiation polarization plane in a longitudinal magnetic field (Faraday effect) on the D{sub 1} line in atomic Rb vapor has been studied with the use of a nanocell with the thickness L varying in the range of 100–900 nm. It has been shown that an important parameter is the ratio L/λ, where λ = 795 nm is the wavelength of laser radiation resonant with the D{sub 1} line. The best parameters of the signal of rotation of the radiation polarization plane have been obtained at the thickness L = λ/2 = 397.5 nm. The fabricated nanocellmore » had a large region with such a thickness. The spectral width of the signal reached at the thickness L = 397.5 nm is approximately 30 MHz, which is much smaller than the spectral width (≈ 500 MHz) reached with ordinary cells with a thickness in the range of 1–100 mm. The parameters of the Faraday rotation signal have been studied as functions of the temperature of the nanocell, the laser power, and the magnetic field strength. The signal has been reliably detected at the laser power P{sub L} ≥ 1 μW, magnetic field strength B ≥ 0.5 G, and the temperature of the nanocell T ≥ 100°C. It has been shown that the maximum rotation angle of the polarization plane in the longitudinal magnetic field is reached on the F{sub g} = 3 → F{sub e} = 2 transition of the {sup 85}Rb atom. The spectral profile of the Faraday rotation signal has a specific shape with a sharp peak, which promotes its applications. In particular, Rb atomic transitions in high magnetic fields about 1000 G are split into a large number of components, which are completely spectrally resolved and allow the study of the behavior of an individual transition.« less

  5. One-year clinical outcome of biodegradable polymer sirolimus-eluting stent in all-comers population. Insight from the ULISSE registry (ULtimaster Italian multicenter all comerS Stent rEgistry).

    PubMed

    Godino, Cosmo; Beneduce, Alessandro; Ferrante, Giuseppe; Ielasi, Alfonso; Pivato, Andrea Carlo; Chiarito, Mauro; Cappelletti, Alberto; Perfetti, Giulia; Magni, Valeria; Prati, Eugenio; Falcone, Stefania; Pierri, Adele; De Martini, Stefano; Montorfano, Matteo; Parisi, Rosario; Rutigliano, David; Locuratolo, Nicola; Anzuini, Angelo; Tespilli, Maurizio; Margonato, Alberto; Benassi, Alberto; Briguori, Carlo; Fabbiocchi, Franco; Reimers, Bernhard; Bartorelli, Antonio; Colombo, Antonio

    2018-06-01

    This study was designed to confirm in a large population of unselected patients the promising results of Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) already shown in previous trial. ULISSE is an observational, multicenter, national registry evaluating all patients undergoing PCI with the Ultimaster® BP-SES. Incidence of 1-year TLF (cardiac death or target vessel MI or clinically indicated TLR) was the primary endpoint. Pre-specified subgroup analysis was performed for diabetic patients and for those with lesion longer than 25 mm, bifurcation and CTO lesions. 1660 patients were enrolled in 9 Italian cardiology centers, 82% were males, mean age of 68 ± 10 years, and 29% were diabetics. Overall 2422 lesions were treated, 65% type B2/C lesions, 7% CTOs, 17% bifurcations and 38% long lesions. The incidence of 1-year TLF was 5%, with 3.2% of clinically indicated TLR. TLF occurred in 8% of the patients with diabetes mellitus, and 7% in bifurcation, 6.7% in CTO and 6.2% in long lesions. Definite overall ST was 0.9%, and 1.2% in patients treated for type B2/C lesions. Multivariate logistic regression analysis identified stenting on unprotected LMT (OR = 4.80), stenting on ISR lesion (OR = 3.19) and need for rotational atherectomy (OR = 6.24) as the strongest independent predictors of TLF. The results of this national all-comers registry show that the Ultimaster® BP-SES real-world performance was comparable with that observed in the clinical trial, with low rate of primary endpoint and TLR. Long term follow-up will be necessary to prove the theoretical advantage of the BP-SES over time. Copyright © 2017. Published by Elsevier B.V.

  6. Utility of the ACC/AHA lesion classification as a predictor of procedural, 30-day and 12-month outcomes in the contemporary percutaneous coronary intervention era.

    PubMed

    Theuerle, James; Yudi, Matias B; Farouque, Omar; Andrianopoulos, Nick; Scott, Peter; Ajani, Andrew E; Brennan, Angela; Duffy, Stephen J; Reid, Christopher M; Clark, David J

    2017-11-15

    Correlations between the ACC/AHA coronary lesion classification and clinical outcomes in the contemporary percutaneous coronary intervention (PCI) era are not well established. We analyzed clinical characteristics and outcomes according to ACC/AHA lesion classification (A, B1, B2, C) in 13,701 consecutive patients from the Melbourne Interventional Group (MIG) registry. Patients presenting with STEMI, cardiogenic shock and out-of-hospital cardiac arrest were excluded. The primary endpoints were 30-day and 12-month mortality. Secondary endpoints were procedural success as well as 30-day and 12-month major adverse cardiac events. Of the 13,701 patients treated, 1,246 (9.1%) had type A lesions, 5,519 (40.3%) had type B1 lesions, 4,449 (32.5%) had Type B2 lesions and 2,487 (18.2%) had Type C lesions. Patients with type C lesions were more likely to be older and have impaired renal function, diabetes, previous myocardial infarction, peripheral vascular disease and prior bypass graft surgery (all P < 0.01). They were also more likely to require rotational atherectomy, drug-eluting stents and longer stent lengths (all P < 0.01). Increasing lesion complexity was associated with lower procedural success (99.6% vs. 99.1% vs. 96.6% vs. 82.7%, P < 0.001) and worse 30-day (0.2% vs. 0.3% vs. 0.7% vs. 0.6%, P < 0.001) and 12-month mortality (2.2% vs. 2.0% vs. 3.2% vs. 2.9%, P <0.01). Kaplan Meier analysis showed complex lesions (type B2 and C) had lower survival at 12-months (P = 0.003). PCI to more complex lesions continues to be associated with lower procedural success rates as well as inferior medium-term clinical outcomes. Thus the ACC/AHA lesion classification should still be calculated preprocedure to predict acute PCI success and clinical outcomes. © 2017 Wiley Periodicals, Inc.

  7. High-dose, single-bolus eptifibatide: a safe and cost-effective alternative to conventional glycoprotein IIb/IIIa inhibitor use for elective coronary interventions.

    PubMed

    Fischell, Tim A; Attia, Tamer; Rane, Santosh; Salman, Waddah

    2006-10-01

    Adjunctive pharmacotherapy with eptifibatide, a glycoprotein (GP) IIb/IIIa inhibitor, as an intravenous bolus followed by infusion has been shown to improve outcomes in elective coronary interventions (PCI). However, bleeding complications and costs have limited the routine adoption of this regimen. The goal of this study was to examine the safety, efficacy and cost-effectiveness of high-dose, single-bolus eptifibatide, without post-intervention infusion, in "real-world" patients undergoing elective PCI. We studied 401 patients with stable and unstable angina who were treated with a high-dose (20 mg), single bolus of eptifibatide plus heparin prior to the start of elective PCI. Exclusion criteria included recent MI, stenting of bypass graft(s), rotational atherectomy and/or brachytherapy. The primary study endpoints were major adverse clinical events (MACE), defined as the in-hospital and 30-day incidence of death from any cause, Q-wave or non-Q-wave MI, repeat target vessel revascularization and/or major bleeding complications. Relevant demographic and procedural characteristics included mean age: 66.4 +/- 11.2; male gender: 242/401 (61%); number of vessels treated per patient: 1.46 +/- 0.42; and number of stents deployed per patient: 1.82 +/- 0.65. In-hospital non-Q-wave MI (CPK and/or CPK-MB > 3 times the upper limit of normal) occurred in 7/401 patients (1.75%) and MACE was 2.25%. Major bleeding complications were seen in 2/401 patients (0.49%). There were 4 additional MACE events at 30-day follow up (total MACE and bleeding = 3.25%). The average anticoagulation cost was 66 dollars/patient. Intravenous eptifibatide, administered as a high-dose (20 mg) single-vial bolus, is a safe, effective and highly cost-effective alternative to the conventional regimens of bolus plus prolonged intravenous GP IIb/IIIa inhibitor infusion for patients undergoing elective PCI.

  8. Understanding sharps injuries in home healthcare: The Safe Home Care qualitative methods study to identify pathways for injury prevention.

    PubMed

    Markkanen, Pia; Galligan, Catherine; Laramie, Angela; Fisher, June; Sama, Susan; Quinn, Margaret

    2015-04-11

    Home healthcare is one of the fastest growing sectors in the United States. Percutaneous injuries from sharp medical devices (sharps) are a source of bloodborne pathogen infections among home healthcare workers and community members. Sharps use and disposal practices in the home are highly variable and there is no comprehensive analysis of the system of sharps procurement, use and disposal in home healthcare. This gap is a barrier to effective public health interventions. The objectives of this study were to i) identify the full range of pathways by which sharps enter and exit the home, stakeholders involved, and barriers for using sharps with injury prevention features; and ii) assess the leverage points for preventive interventions. This study employed qualitative research methods to develop two systems maps of the use of sharps and prevention of sharps injuries in home healthcare. Twenty-six in-depth interview sessions were conducted including home healthcare agency clinicians, public health practitioners, sharps device manufacturers, injury prevention advocates, pharmacists and others. Interview transcripts were audio-recorded and analyzed thematically using NVIVO qualitative research analysis software. Analysis of supporting archival material also was conducted. All findings guided development of the two maps. Sharps enter the home via multiple complex pathways involving home healthcare providers and home users. The providers reported using sharps with injury prevention features. However, home users' sharps seldom had injury prevention features and sharps were commonly re-used for convenience and cost-savings. Improperly discarded sharps present hazards to caregivers, waste handlers, and community members. The most effective intervention potential exists at the beginning of the sharps systems maps where interventions can eliminate or minimize sharps injuries, in particular with needleless treatment methods and sharps with injury prevention features. Manufacturers and insurance providers can improve safety with more affordable and accessible sharps with injury prevention features for home users. Sharps disposal campaigns, free-of-charge disposal containers, and convenient disposal options remain essential. Sharps injuries are preventable through public health actions that promote needleless treatment methods, sharps with injury prevention features, and safe disposal practices. Communication about hazards regarding sharps is needed for all home healthcare stakeholders.

  9. Flight trajectory of a rotating golf ball with grooves

    NASA Astrophysics Data System (ADS)

    Baek, Moonheum; Kim, Jooha; Choi, Haecheon

    2014-11-01

    Dimples are known to reduce drag on a sphere by the amount of 50% as compared to a smooth surface. Despite the advantage of reducing drag, dimples deteriorate the putting accuracy owing to their sharp edges. To minimize this putting error but maintain the same flight distance, we have devised a grooved golf ball (called G ball hereafter) for several years. In this study, we modify the shape and pattern of grooves, and investigate the flow characteristics of the G ball by performing wind-tunnel experiments at the Reynolds numbers of 0 . 5 ×105 - 2 . 5 ×105 and the spin ratios (ratio of surface velocity to the free-stream velocity) of 0 - 0.6 that include the real golf-ball velocity and rotational speed. We measure the drag and lift forces on the rotating G ball and compare them with those of a smooth ball and two well-known dimpled balls. The lift-to-drag ratio of the G ball is much higher than that of a smooth ball and is in between those of the two dimpled balls. The trajectories of flying golf balls are computed. The flight distance of G ball is almost the same as that of one dimpled ball but slightly shorter than that of the other dimpled ball. The fluid-dynamic aspects of these differences will be discussed at the talk. Supported by 2011-0028032, 2014M3C1B1033980.

  10. Torsional Oscillations in a Global Solar Dynamo

    NASA Astrophysics Data System (ADS)

    Beaudoin, P.; Charbonneau, P.; Racine, E.; Smolarkiewicz, P. K.

    2013-02-01

    We characterize and analyze rotational torsional oscillations developing in a large-eddy magnetohydrodynamical simulation of solar convection (Ghizaru, Charbonneau, and Smolarkiewicz, Astrophys. J. Lett. 715, L133, 2010; Racine et al., Astrophys. J. 735, 46, 2011) producing an axisymmetric, large-scale, magnetic field undergoing periodic polarity reversals. Motivated by the many solar-like features exhibited by these oscillations, we carry out an analysis of the large-scale zonal dynamics. We demonstrate that simulated torsional oscillations are not driven primarily by the periodically varying large-scale magnetic torque, as one might have expected, but rather via the magnetic modulation of angular-momentum transport by the large-scale meridional flow. This result is confirmed by a straightforward energy analysis. We also detect a fairly sharp transition in rotational dynamics taking place as one moves from the base of the convecting layers to the base of the thin tachocline-like shear layer formed in the stably stratified fluid layers immediately below. We conclude by discussing the implications of our analyses with regard to the mechanism of amplitude saturation in the global dynamo operating in the simulation, and speculate on the possible precursor value of torsional oscillations for the forecast of solar-cycle characteristics.

  11. NuSTAR AND SWIFT Observations of the Fast Rotating Magnetized White Dwarf AE Aquarii

    NASA Technical Reports Server (NTRS)

    Kitaguchi, Takao; An, Hongjun; Beloborodov, Andrei M.; Gotthelf, Eric V.; Hayashi, Takayuki; Kaspi, Victoria M.; Rana, Vikram R.; Boggs, Steven E.; Christensen, Finn E.; Craig, William W.; hide

    2014-01-01

    AE Aquarii is a cataclysmic variable with the fastest known rotating magnetized white dwarf (P(sub spin) = 33.08 s). Compared to many intermediate polars, AE Aquarii shows a soft X-ray spectrum with a very low luminosity (LX (is) approximately 10(exp 31) erg per second). We have analyzed overlapping observations of this system with the NuSTAR and the Swift X-ray observatories in 2012 September. We find the 0.5-30 keV spectra to be well fitted by either an optically thin thermal plasma model with three temperatures of 0.75(+0.18 / -0.45), 2.29(+0.96 / -0.82), and 9.33 (+6.07 / -2.18) keV, or an optically thin thermal plasma model with two temperatures of 1.00 (+0.34 / -0.23) and 4.64 (+1.58 / -0.84) keV plus a power-law component with photon index of 2.50 (+0.17 / -0.23). The pulse profile in the 3-20 keV band is broad and approximately sinusoidal, with a pulsed fraction of 16.6% +/- 2.3%. We do not find any evidence for a previously reported sharp feature in the pulse profile.

  12. NuStar and Swift Observations of the Fast Rotating Magnetized White Dwarf AE Aquarii

    NASA Technical Reports Server (NTRS)

    Kitaguchi, Takao; An, Hongjun; Beloborodov, Andrei M.; Gotthelf, Eric V.; Hayashi, Takayuki; Kaspi, Victoria M.; Rana, Vikram R.; Boggs, Steven E.; Christensen, Finn E.; Craig, William W.; hide

    2014-01-01

    AE Aquarii is a cataclysmic variable with the fastest known rotating magnetized white dwarf (P(sub spin) = 33.08 s). Compared to many intermediate polars, AE Aquarii shows a soft X-ray spectrum with a very low luminosity (LX (is) approximately 10(exp 31) erg per second). We have analyzed overlapping observations of this system with the NuSTAR and the Swift X-ray observatories in 2012 September. We find the 0.5-30 keV spectra to be well fitted by either an optically thin thermal plasma model with three temperatures of 0.75(+0.18 / -0.45), 2.29(+0.96 / -0.82), and 9.33 (+6.07 / -2.18) keV, or an optically thin thermal plasma model with two temperatures of 1.00 (+0.34 / -0.23) and 4.64 (+1.58 / -0.84) keV plus a power-law component with photon index of 2.50 (+0.17 / -0.23). The pulse profile in the 3-20 keV band is broad and approximately sinusoidal, with a pulsed fraction of 16.6% +/- 2.3%. We do not find any evidence for a previously reported sharp feature in the pulse profile.

  13. High-Resolution Infrared Spectrscopy of the Hydroxymethyl Radical in Solid Parahydrogen

    NASA Astrophysics Data System (ADS)

    Balabanoff, Morgan E.; Anderson, David T.

    2016-06-01

    Interest in the hydroxymethyl radical, CH2OH, stems primarily from its importance as a reaction intermediate. However, this radical is also of interest from a spectroscopic point of view with large amplitude COH torsional tunneling and out of plane CH2 wagging motions. The first IR detection of CH2OH was accomplished via matrix isolation spectroscopy over 40 years ago by Jacox. Reisler and co-workers detected CH2OH in the gas-phase using the sensitivity of double resonance ionization detected IR spectroscopy to probe the OH stretch, asymmetric CH stretch, and symmetric CH stretch vibrational modes with partial rotational resolution (0.4 wn). Most recently, the Nesbitt group published the first fully rotationally resolved IR spectrum of CH2OH via the Ka=0←0 band of the symmetric CH stretch. These researchers were able to unambiguously assign the identified transitions to a Watson A-reduced symmetric top Hamiltonian thereby producing improved values for the symmetric CH stretch rotational constants and vibrational band origin. However, in this same work the authors point out a number of remaining unresolved issues. Motivated by these gas-phase observations, we decided to return to the matrix isolation studies of CH2OH, however utilizing solid parahydrogen as a matrix host to improve upon the sensitivity and resolution of the previous matrix isolation studies. Based on our measurements, while the end-over-end rotation of the CH2OH radical is quenched, rotational motion around the a-axis is nearly free permitting both A-type and B-type transitions to be resolved. In the case of the OH stretch mode, both A-type and B-type transitions are observed with an energy difference that makes sense based on the gas-phase CH2OH rotational constants. However, for the symmetric CH stretch mode, the same mode recently assigned by Nesbitt and co-workers, two absorption features are also observed but the energy difference and intensities of the two features do not match predictions based on the rotational constants. M.E. Jacox, D.E. Milligan, J. Mol. Spec. 47, 148-162 (1973) L. Feng, J. Wei, H. Reisler, J. Phys. Chem. A 108, 7903-7908 (2004). M.A. Roberts, E.N. Sharp-Williams, D.J. Nesbitt, J. Phys. Chem. A 117, 7042-7049 (2013).

  14. Angle-independent measure of motion for image-based gating in 3D coronary angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lehmann, Glen C.; Holdsworth, David W.; Drangova, Maria

    2006-05-15

    The role of three-dimensional (3D) image guidance for interventional procedures and minimally invasive surgeries is increasing for the treatment of vascular disease. Currently, most interventional procedures are guided by two-dimensional x-ray angiography, but computed rotational angiography has the potential to provide 3D geometric information about the coronary arteries. The creation of 3D angiographic images of the coronary arteries requires synchronization of data acquisition with respect to the cardiac cycle, in order to minimize motion artifacts. This can be achieved by inferring the extent of motion from a patient's electrocardiogram (ECG) signal. However, a direct measurement of motion (from the 2Dmore » angiograms) has the potential to improve the 3D angiographic images by ensuring that only projections acquired during periods of minimal motion are included in the reconstruction. This paper presents an image-based metric for measuring the extent of motion in 2D x-ray angiographic images. Adaptive histogram equalization was applied to projection images to increase the sharpness of coronary arteries and the superior-inferior component of the weighted centroid (SIC) was measured. The SIC constitutes an image-based metric that can be used to track vessel motion, independent of apparent motion induced by the rotational acquisition. To evaluate the technique, six consecutive patients scheduled for routine coronary angiography procedures were studied. We compared the end of the SIC rest period ({rho}) to R-waves (R) detected in the patient's ECG and found a mean difference of 14{+-}80 ms. Two simultaneous angular positions were acquired and {rho} was detected for each position. There was no statistically significant difference (P=0.79) between {rho} in the two simultaneously acquired angular positions. Thus we have shown the SIC to be independent of view angle, which is critical for rotational angiography. A preliminary image-based gating strategy that employed the SIC was compared to an ECG-based gating strategy in a porcine model. The image-based gating strategy selected 61 projection images, compared to 45 selected by the ECG-gating strategy. Qualitative comparison revealed that although both the SIC-based and ECG-gated reconstructions decreased motion artifact compared to reconstruction with no gating, the SIC-based gating technique increased the conspicuity of smaller vessels when compared to ECG gating in maximum intensity projections of the reconstructions and increased the sharpness of a vessel cross section in multi-planar reformats of the reconstruction.« less

  15. Directional Atherectomy With Antirestenotic Therapy vs Drug-Coated Balloon Angioplasty Alone for Isolated Popliteal Artery Lesions.

    PubMed

    Stavroulakis, Konstantinos; Schwindt, Arne; Torsello, Giovanni; Stachmann, Arne; Hericks, Christiane; Bosiers, Michel J; Beropoulis, Efthymios; Stahlhoff, Stefan; Bisdas, Theodosios

    2017-04-01

    To report a single-center study comparing drug-coated balloon (DCB) angioplasty vs directional atherectomy with antirestenotic therapy (DAART) for isolated lesions of the popliteal artery. Seventy-two patients were treated with either DCB angioplasty alone (n=31) or with DAART (n=41) for isolated popliteal artery stenotic disease between October 2009 and December 2015. The majority of patients presented with lifestyle-limiting claudication (74% vs 86%, respectively). Vessel calcification (29% vs 29%, respectively), mean lesion length (47 vs 42 mm, respectively), and number of runoff vessels were comparable between the groups. The primary outcome measure was primary patency; secondary outcomes were technical success (<30% residual stenosis or bailout stenting), secondary patency, and freedom from clinically driven target lesion revascularization (TLR). The technical success rate following DCB was 84% vs 93% (p=0.24) after DAART. The 12-month primary patency rate was significantly higher in the DAART group (65% vs 82%; hazard ratio 2.64, 95% confidence interval 1.09 to 6.37, p=0.021), while freedom from TLR did not differ between the 2 treatment strategies (82% vs 94%, p=0.072). Secondary patency at 12 months was identical for both groups (96% vs 96%). Although not statistically significant, bailout stenting was more common after DCB angioplasty (16% vs 5% for DAART, p=0.13) and aneurysmal degeneration of the popliteal artery was seen more often after DAART (7% vs 0% for DCB alone, p=0.25). Popliteal artery injury was observed in 2 patients treated using DAART (5% vs 0% for DCB alone, p=0.5), whereas distal embolization rates were comparable between the groups (3% for DCB alone vs 5% for DAART, p=0.99). In this study, the use of DAART was associated with a higher primary patency rate compared with DCB angioplasty for isolated popliteal lesions. Nonetheless, both treatment options were associated with excellent 12-month secondary patency. Aneurysmal degeneration of the popliteal artery and increased bailout stenting could compromise the outcomes of DAART and DCB, respectively.

  16. Randomized Comparison of Paclitaxel-Eluting Balloon and Stenting Versus Plain Balloon Plus Stenting Versus Directional Atherectomy for Femoral Artery Disease (ISAR-STATH).

    PubMed

    Ott, Ilka; Cassese, Salvatore; Groha, Philipp; Steppich, Birgit; Hadamitzky, Martin; Ibrahim, Tareq; Kufner, Sebastian; Dewitz, Karl; Hiendlmayer, Regina; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan; Fusaro, Massimiliano

    2017-06-06

    Atherosclerosis in the superficial femoral artery is common in patients suffering from peripheral artery disease. Paclitaxel-eluting balloon (PEB) angioplasty, stenting, and directional atherectomy (DA) have provided new options for the treatment of superficial femoral artery disease; however, the comparative efficacy of these interventional strategies remains uncertain. One hundred and fifty-five patients with symptomatic peripheral artery disease due to de novo superficial femoral artery stenotic or occlusive lesions were randomized to treatment with plain balloon angioplasty (BA) followed by PEB angioplasty and stenting (n=48), BA and stenting (n=52), or DA with distal protection and bailout stenting (n=55). The primary end point of the study was percentage diameter stenosis after 6 months measured by angiography. Other end points included target lesion revascularization, thrombosis, ipsilateral amputation, binary restenosis, and all-cause mortality at 6 and 24 months. Baseline and lesion characteristics were comparable in all groups with a mean lesion length of 65.9±46.8 mm and 56% total occlusions. At 6 months angiography, the percent diameter stenosis was significantly lower in patients treated by PEB angioplasty and stenting (34±31%) as compared with BA angioplasty and stenting (56±29%, P =0.009) or DA (55±29%, P =0.007). Similarly, binary restenosis was significantly lower after treatment with PEB and stenting as compared with BA and stenting or DA. Clinical follow-up at 24 months revealed a lower risk for target lesion revascularization after PEB angioplasty and stenting as compared with BA and stenting or DA. We found no difference in terms of target lesion thrombosis and mortality among groups, and no patient underwent amputation. Treatment of de novo superficial femoral artery lesions with PEB angioplasty and stenting is superior to BA angioplasty and stenting or DA in terms of angiographic diameter stenosis at 6 months and target lesion revascularization at 24 months. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00986752. © 2017 American Heart Association, Inc.

  17. The potential cost-effectiveness of the Diamondback 360® Coronary Orbital Atherectomy System for treating de novo, severely calcified coronary lesions: an economic modeling approach

    PubMed Central

    Chambers, Jeffrey; Généreux, Philippe; Lee, Arthur; Lewin, Jack; Young, Christopher; Crittendon, Janna; Mann, Marita; Garrison, Louis P.

    2015-01-01

    Background: Patients who undergo percutaneous coronary intervention (PCI) for severely calcified coronary lesions have long been known to have worse clinical and economic outcomes than patients with no or mildly calcified lesions. We sought to assess the likely cost-effectiveness of using the Diamondback 360® Orbital Atherectomy System (OAS) in the treatment of de novo, severely calcified lesions from a health-system perspective. Methods and results: In the absence of a head-to-head trial and long-term follow up, cost-effectiveness was based on a modeled synthesis of clinical and economic data. A cost-effectiveness model was used to project the likely economic impact. To estimate the net cost impact, the cost of using the OAS technology in elderly (⩾ 65 years) Medicare patients with de novo severely calcified lesions was compared with cost offsets. Elderly OAS patients from the ORBIT II trial (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) [ClinicalTrials.gov identifier: NCT01092426] were indirectly compared with similar patients using observational data. For the index procedure, the comparison was with Medicare data, and for both revascularization and cardiac death in the following year, the comparison was with a pooled analysis of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI)/Acute Catheterization and Urgent Intervention Triage Strategy (ACUITY) trials. After adjusting for differences in age, gender, and comorbidities, the ORBIT II mean index procedure costs were 17% (p < 0.001) lower, approximately US$2700. Estimated mean revascularization costs were lower by US$1240 in the base case. These cost offsets in the first year, on average, fully cover the cost of the device with an additional 1.2% cost savings. Even in the low-value scenario, the use of the OAS is cost-effective with a cost per life-year gained of US$11,895. Conclusions: Based on economic modeling, the recently approved coronary OAS device is projected to be highly cost-effective for patients who undergo PCI for severely calcified lesions. PMID:26702147

  18. Mid-term outcomes of orbital atherectomy combined with drug-coated balloon angioplasty for treatment of femoropopliteal disease.

    PubMed

    Foley, T Raymond; Cotter, Ryan P; Kokkinidis, Damianos G; Nguyen, Daniel D; Waldo, Stephen W; Armstrong, Ehrin J

    2017-05-01

    To assess the intraprocedural and mid-term outcomes of orbital atherectomy (OA) combined with drug-coated balloon (DCB) angioplasty for the treatment of calcified femoropopliteal disease. In this single-center cohort, 89 patients (139 lesions) were treated with DCB angioplasty for claudication or critical limb ischemia (CLI). Angiographic characteristics and procedural outcomes were reviewed for patients treated with or without adjunctive OA. Lesion calcification was graded using two previously published scoring systems, the angiographic calcium score (ACS) and the peripheral artery calcification scoring system (PACSS). Among 139 lesions, 40 (29%) were treated with OA + DCB. Mean lesion length was 135 ± 100 mm for lesions treated with OA + DCB and 139 ± 100 mm for DCB alone (P = 0.9). Moderate to severe calcification was present in 83% of patients treated with OA, compared to 42% of patients treated with DCB alone (P < 0.001). Lesions treated with OA + DCB were less likely to require bailout stenting (18% vs. 39%, P =0.01). Rates of embolization (0% in OA + DCB vs. 2% in DCB only, P = 0.4), dissection (13% vs. 14%, P = 0.8), and perforation (0%) did not differ significantly between groups. The freedom from TLR at 1 year was 82% in both groups (P = 0.6) while primary patency was 81% in-patients treated with DCB alone and 77% in-patients treated with DCB with concomitant OA (P = 0.8). In this single-center analysis of patients undergoing DCB angioplasty for claudication or CLI, OA was most often used for the treatment of severely calcified lesions. These lesions were more likely to be treated with scoring balloons and less likely to require bailout stenting. At 1 year, target lesion revascularization and primary patency was similar in patients treated with and without adjunctive OA, despite the higher lesion complexity among those receiving the combination procedure. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  19. Lower extremity revascularization using directional atherectomy: 12-month prospective results of the DEFINITIVE LE study.

    PubMed

    McKinsey, James F; Zeller, Thomas; Rocha-Singh, Krishna J; Jaff, Michael R; Garcia, Lawrence A

    2014-08-01

    The aim of this study was to assess the safety and effectiveness of directional atherectomy (DA) for endovascular treatment of peripheral arterial disease (PAD) in infrainguinal arteries in patients with claudication or critical limb ischemia. To date, no prospective, multicenter, independently-adjudicated study has evaluated the effectiveness and durability of DA in the treatment of PAD. Previous DA studies have not been prospectively powered to evaluate any differences in outcomes in patients with and without diabetes. DEFINITIVE LE (Determination of EFfectiveness of the SilverHawk(®) PerIpheral Plaque ExcisioN System (SIlverHawk Device) for the Treatment of Infrainguinal VEssels / Lower Extremities) prospectively enrolled subjects at 47 multinational centers with an infrainguinal lesion length up to 20 cm. Primary endpoints were defined as primary patency at 12 months for claudicants and freedom from major unplanned amputation for critical limb ischemia (CLI) subjects. A pre-specified statistical hypothesis evaluated noninferiority of primary patency in diabetic versus nondiabetic claudicants. Independent angiographic and sonographic core laboratories assessed outcomes, and events were adjudicated by a clinical events committee. A total of 800 subjects were enrolled. The 12-month primary patency was 78% (95% confidence interval: 74.0% to 80.6%) in claudicants, with a 77% rate in the diabetic subgroup versus 78% in the nondiabetic subgroup (noninferior, p < 0.001). The rate of freedom from major unplanned amputation of the target limb at 12 months in CLI subjects was 95% (95% confidence interval: 90.7% to 97.4%). Periprocedural adverse events included embolization (3.8%), perforation (5.3%), and abrupt closure (2.0%). The bail-out stent rate was 3.2%. The DEFINITIVE LE study demonstrated that DA is a safe and effective treatment modality at 12 months for a diverse patient population with either claudication or CLI. Furthermore, DA was shown to be noninferior for treating PAD in patients with diabetes compared with those without diabetes. (Study of SilverHawk/TurboHawk in Lower Extremity Vessels [DEFINITIVE LE]; NCT00883246). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. The potential cost-effectiveness of the Diamondback 360® Coronary Orbital Atherectomy System for treating de novo, severely calcified coronary lesions: an economic modeling approach.

    PubMed

    Chambers, Jeffrey; Généreux, Philippe; Lee, Arthur; Lewin, Jack; Young, Christopher; Crittendon, Janna; Mann, Marita; Garrison, Louis P

    2016-04-01

    Patients who undergo percutaneous coronary intervention (PCI) for severely calcified coronary lesions have long been known to have worse clinical and economic outcomes than patients with no or mildly calcified lesions. We sought to assess the likely cost-effectiveness of using the Diamondback 360(®) Orbital Atherectomy System (OAS) in the treatment of de novo, severely calcified lesions from a health-system perspective. In the absence of a head-to-head trial and long-term follow up, cost-effectiveness was based on a modeled synthesis of clinical and economic data. A cost-effectiveness model was used to project the likely economic impact. To estimate the net cost impact, the cost of using the OAS technology in elderly (⩾ 65 years) Medicare patients with de novo severely calcified lesions was compared with cost offsets. Elderly OAS patients from the ORBIT II trial (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) [ClinicalTrials.gov identifier: NCT01092426] were indirectly compared with similar patients using observational data. For the index procedure, the comparison was with Medicare data, and for both revascularization and cardiac death in the following year, the comparison was with a pooled analysis of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI)/Acute Catheterization and Urgent Intervention Triage Strategy (ACUITY) trials. After adjusting for differences in age, gender, and comorbidities, the ORBIT II mean index procedure costs were 17% (p < 0.001) lower, approximately US$2700. Estimated mean revascularization costs were lower by US$1240 in the base case. These cost offsets in the first year, on average, fully cover the cost of the device with an additional 1.2% cost savings. Even in the low-value scenario, the use of the OAS is cost-effective with a cost per life-year gained of US$11,895. Based on economic modeling, the recently approved coronary OAS device is projected to be highly cost-effective for patients who undergo PCI for severely calcified lesions. © The Author(s), 2015.

  1. Lower extremity endovascular interventions: can we improve cost-efficiency?

    PubMed

    O'Brien-Irr, Monica S; Harris, Linda M; Dosluoglu, Hasan H; Dayton, Merril; Dryjski, Maciej L

    2008-05-01

    Management of lower extremity arterial disease with endovascular intervention is on the rise. Current practice patterns vary widely across and within specialty practices that perform endovascular intervention. This study evaluated reimbursement and costs of different approaches for offering endovascular intervention and identified strategies to improve cost-efficiency. The medical records of all patients admitted to a university health system during 2005 for an endovascular intervention were retrospectively reviewed. Procedure type, setting, admission status, and financial data were recorded. Groups were compared using analysis of variance, Student t test for independent samples, and chi2. A total of 296 endovascular interventions were completed, and 184 (62%) met inclusion criteria. Atherectomy and stenting were significantly more costly when performed in the operating room than in the radiology suite: atherectomy, dollars 6596 vs dollars 4867 (P = .002); stent, dollars 5884 vs dollars 3292, (P < .001); angioplasty, dollars 2251 vs dollars 1881 (P = .46). Reimbursement was significantly higher for inpatient vs ambulatory admissions (P < .001). Costs were lowest when the endovascular intervention was done in the radiology suite on an ambulatory basis and highest when done as an inpatient in the operating room (dollars 5714 vs dollars 12,278; P < .001). Contribution margins were significantly higher for inpatients. Net profit was appreciated only for interventions done as an inpatient in the radiology suite. Reimbursement, contribution margins, and net profit were significantly lower among private pay patients in both the ambulatory and inpatient setting. The 30-day hospital readmission after ambulatory procedures was seven patients (6%). Practice patterns for endovascular interventions differ considerably. Costs vary by procedure and setting, and reimbursement depends on admission status and accurate documentation; these dynamics affect affordability. Organizing vascular services within a hub will ensure that care is delivered in the most cost-efficient manner. Guidelines may include designating the radiology suite as the primary venue for endovascular interventions because it is less costly than the operating room. Selective stenting policies should be considered. Contracts with private insurers must include carve-outs for stent costs and commensurate reimbursement for ambulatory procedures, and Current Procedural Terminology (CPT; American Medical Association, Chicago, Ill) coding must be proficient to make ambulatory endovascular interventions fiscally acceptable.

  2. Morin-like spin canting in the magnetic CaFe5O7 ferrite: A combined neutron and Mössbauer study

    NASA Astrophysics Data System (ADS)

    Delacotte, C.; Bréard, Y.; Caignaert, V.; Hardy, V.; Greneche, J. M.; Hébert, S.; Suard, E.; Pelloquin, D.

    2017-03-01

    Magnetic structure of CaFe5O7 ferrite has been studied jointly from neutron powder diffraction data and spectroscopic Mössbauer measurements in the thermal range from 5 to 500 K. This coupled work highlights three distinct magnetic domains around two specific temperatures: TM=125 K and TN=360 K. The latter corroborates the structural monoclinic-orthorhombic transition previously reported by transmission electron microscopy techniques and X-ray thermodiffractometry. Complementary heat capacity measurements have confirmed this first order transition with a sharp peak at 360 K. Interestingly, this large study has revealed a second magnetic transition associated to a spin rotation at 125 K similar to this one reported by Morin in α-Fe2O3 hematite at TM=260 K.

  3. Determination of the light ion abundances in the strong-helium star HR 3089

    NASA Technical Reports Server (NTRS)

    Lester, J. B.

    1975-01-01

    Using line blanketed model stellar atmospheres and a spectrum synthesis approach, a differential abundance study of the ultraviolet spectrum of HR 3089 relative to the normal star lambda Sco was performed. Both stars were found to have the same abundances of carbon and silicon, but the helium and nitrogen are significantly enhanced in HR 3089. The atmospheric parameters and the distribution of abundances found for HR 3089 agree well with the results of Osmer and Peterson on sharp-lined helium-rich stars. The rotational velocity of 160 km/sec found for HR 3089 places a constraint on the role of diffusion in producing the abundance anomalies. Examination of the resonance lines of C II, N II, Si III and Si IV shows no evidence for mass loss in either star.

  4. Formation of Iapetus' extreme albedo dichotomy by exogenically triggered thermal ice migration.

    PubMed

    Spencer, John R; Denk, Tilmann

    2010-01-22

    The extreme albedo asymmetry of Saturn's moon Iapetus, which is about 10 times as bright on its trailing hemisphere as on its leading hemisphere, has been an enigma for three centuries. Deposition of exogenic dark material on the leading side has been proposed as a cause, but this alone cannot explain the global shape, sharpness, and complexity of the transition between Iapetus' bright and dark terrain. We demonstrate that all these characteristics, and the asymmetry's large amplitude, can be plausibly explained by runaway global thermal migration of water ice, triggered by the deposition of dark material on the leading hemisphere. This mechanism is unique to Iapetus among the saturnian satellites because its slow rotation produces unusually high daytime temperatures and water ice sublimation rates for a given albedo.

  5. Residual motion compensation in ECG-gated interventional cardiac vasculature reconstruction

    NASA Astrophysics Data System (ADS)

    Schwemmer, C.; Rohkohl, C.; Lauritsch, G.; Müller, K.; Hornegger, J.

    2013-06-01

    Three-dimensional reconstruction of cardiac vasculature from angiographic C-arm CT (rotational angiography) data is a major challenge. Motion artefacts corrupt image quality, reducing usability for diagnosis and guidance. Many state-of-the-art approaches depend on retrospective ECG-gating of projection data for image reconstruction. A trade-off has to be made regarding the size of the ECG-gating window. A large temporal window is desirable to avoid undersampling. However, residual motion will occur in a large window, causing motion artefacts. We present an algorithm to correct for residual motion. Our approach is based on a deformable 2D-2D registration between the forward projection of an initial, ECG-gated reconstruction, and the original projection data. The approach is fully automatic and does not require any complex segmentation of vasculature, or landmarks. The estimated motion is compensated for during the backprojection step of a subsequent reconstruction. We evaluated the method using the publicly available CAVAREV platform and on six human clinical datasets. We found a better visibility of structure, reduced motion artefacts, and increased sharpness of the vessels in the compensated reconstructions compared to the initial reconstructions. At the time of writing, our algorithm outperforms the leading result of the CAVAREV ranking list. For the clinical datasets, we found an average reduction of motion artefacts by 13 ± 6%. Vessel sharpness was improved by 25 ± 12% on average.

  6. Backbending in the {}_{90}^{223}{Th} nucleus: presentation of the consistency of two different experiments

    NASA Astrophysics Data System (ADS)

    Maquart, G.; Astier, A.; Ducoin, C.; Guinet, D.; Stézowski, O.; Augey, L.; Chaix, L.; Companis, I.; Dudouet, J.; Lehaut, G.; Mancuso, C.; Redon, N.; Vancraeyenest, A.

    2017-06-01

    The detailed level structure of {}223{Th} has been investigated in measurements of γ radiations following the fusion-evaporation channel of the {}208{Pb}{(}18{{O}},3n{)}223{Th} reaction at 85 MeV beam energy. The present data are extracted from two different experiments performed with the EUROBALL IV and JUROGAM II γ-ray detector array, respectively. The level structure has been extended up to spin 49/2 and 33 new γ-rays have been added using triple-γ coincidence data. The spins and parities of the newly observed states have been confirmed by angular distribution ratios. In addition to the two known yrast bands based on a K=5/2 configuration, a non-yrast band has been established up to spin 35/2. This observation has brought to light a sharp backbending occuring at the highest spins promoting the {}223{Th} as the heavier thorium isotope having an accident observed in its moment of inertia at high spin. We interpret this new structure as based on the same configuration as the yrast band in {}221{Th} having dominant K=1/2 contribution. At the highest spin a backbending occurs around a rotational frequency of {\\hslash }ω =0.23 {MeV}, very close to the one predicted in the {}222{Th} where a sharp transition to a reflection-symmetric shape is expected.

  7. Occupational safety among dental health-care workers

    PubMed Central

    Shimoji, Shigehiro; Ishihama, Kohji; Yamada, Hidefumi; Okayama, Masaki; Yasuda, Kouichi; Shibutani, Tohru; Ogasawara, Tadashi; Miyazawa, Hiroo; Furusawa, Kiyofumi

    2010-01-01

    Compared to other health-care workers, dental health-care workers come in close contact with patients and use a variety of sharp and high-speed rotating instruments. It is important to understand the characteristics of the occupational accidents that occur. We reviewed incident reports from April 1, 2005, to March 31, 2010, at Matsumoto Dental University Hospital. In addition, questionnaires dealing with identification of occupational safety issues, especially splash exposures, were conducted for dentists, dental hygienists, and nurses. Thirty-two occupational injuries were reported during the study period, including 23 sharp instrument injuries (71.9%), 6 splash exposures (18.8%), and 3 others. Of the six splash exposures, only two cases involved potential contamination with blood or other potentially infectious patient material. Of the 66 workers who experienced sharps injuries, 20 workers (30.3%, 20/66) reported them to the hospital work safety team. The questionnaire revealed high incident of splash exposures and conjunctiva exposures: 87.9% (51/58) and 60.3% (35/58) in dentists and 88.6% (39/44) and 61.4% (27/44) in dental hygienists. The compliance rate for routine use of protective eyewear was 60.3% (35/58) for dentists and 34.1% (15/44) for hygienists. Of the presented informational items included in the questionnaire, those that strongly persuaded respondents to use protective eyewear were ‘splatters from the patient’s mouth contain blood’ (90%, 99/110) and ‘dental operations at our clinic are performed based only on a questionnaire without serious examinations for HBV, HCV, and HIV’ (71.8%, 79/110). The reason of low compliance of protective eyewear among dentists might relate to fine dental procedures. Appropriate information is important for the motive of wearing personal protective equipment, and an early educational program may have a potential to increase compliance with the use of that equipment. PMID:23745061

  8. SU-E-J-29: Automatic Image Registration Performance of Three IGRT Systems for Prostate Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barber, J; University of Sydney, Sydney, NSW; Sykes, J

    Purpose: To compare the performance of an automatic image registration algorithm on image sets collected on three commercial image guidance systems, and explore its relationship with imaging parameters such as dose and sharpness. Methods: Images of a CIRS Virtually Human Male Pelvis phantom (VHMP) were collected on the CBCT systems of Varian TrueBeam/OBI and Elekta Synergy/XVI linear accelerators, across a range of mAs settings; and MVCT on a Tomotherapy Hi-ART accelerator with a range of pitch. Using the 6D correlation ratio algorithm of XVI, each image was registered to a mask of the prostate volume with a 5 mm expansion.more » Registrations were repeated 100 times, with random initial offsets introduced to simulate daily matching. Residual registration errors were calculated by correcting for the initial phantom set-up error. Automatic registration was also repeated after reconstructing images with different sharpness filters. Results: All three systems showed good registration performance, with residual translations <0.5mm (1σ) for typical clinical dose and reconstruction settings. Residual rotational error had larger range, with 0.8°, 1.2° and 1.9° for 1σ in XVI, OBI and Tomotherapy respectively. The registration accuracy of XVI images showed a strong dependence on imaging dose, particularly below 4mGy. No evidence of reduced performance was observed at the lowest dose settings for OBI and Tomotherapy, but these were above 4mGy. Registration failures (maximum target registration error > 3.6 mm on the surface of a 30mm sphere) occurred in 5% to 10% of registrations. Changing the sharpness of image reconstruction had no significant effect on registration performance. Conclusions: Using the present automatic image registration algorithm, all IGRT systems tested provided satisfactory registrations for clinical use, within a normal range of acquisition settings.« less

  9. The Helioseismic and Magnetic Imager (HMI) Vector Magnetic Field Pipeline: Overview and Performance

    NASA Astrophysics Data System (ADS)

    Hoeksema, J. Todd; Liu, Yang; Hayashi, Keiji; Sun, Xudong; Schou, Jesper; Couvidat, Sebastien; Norton, Aimee; Bobra, Monica; Centeno, Rebecca; Leka, K. D.; Barnes, Graham; Turmon, Michael

    2014-09-01

    The Helioseismic and Magnetic Imager (HMI) began near-continuous full-disk solar measurements on 1 May 2010 from the Solar Dynamics Observatory (SDO). An automated processing pipeline keeps pace with observations to produce observable quantities, including the photospheric vector magnetic field, from sequences of filtergrams. The basic vector-field frame list cadence is 135 seconds, but to reduce noise the filtergrams are combined to derive data products every 720 seconds. The primary 720 s observables were released in mid-2010, including Stokes polarization parameters measured at six wavelengths, as well as intensity, Doppler velocity, and the line-of-sight magnetic field. More advanced products, including the full vector magnetic field, are now available. Automatically identified HMI Active Region Patches (HARPs) track the location and shape of magnetic regions throughout their lifetime. The vector field is computed using the Very Fast Inversion of the Stokes Vector (VFISV) code optimized for the HMI pipeline; the remaining 180∘ azimuth ambiguity is resolved with the Minimum Energy (ME0) code. The Milne-Eddington inversion is performed on all full-disk HMI observations. The disambiguation, until recently run only on HARP regions, is now implemented for the full disk. Vector and scalar quantities in the patches are used to derive active region indices potentially useful for forecasting; the data maps and indices are collected in the SHARP data series, hmi.sharp_720s. Definitive SHARP processing is completed only after the region rotates off the visible disk; quick-look products are produced in near real time. Patches are provided in both CCD and heliographic coordinates. HMI provides continuous coverage of the vector field, but has modest spatial, spectral, and temporal resolution. Coupled with limitations of the analysis and interpretation techniques, effects of the orbital velocity, and instrument performance, the resulting measurements have a certain dynamic range and sensitivity and are subject to systematic errors and uncertainties that are characterized in this report.

  10. Analysis of sharpness increase by image noise

    NASA Astrophysics Data System (ADS)

    Kurihara, Takehito; Aoki, Naokazu; Kobayashi, Hiroyuki

    2009-02-01

    Motivated by the reported increase in sharpness by image noise, we investigated how noise affects sharpness perception. We first used natural images of tree bark with different amounts of noise to see whether noise enhances sharpness. Although the result showed sharpness decreased as noise amount increased, some observers seemed to perceive more sharpness with increasing noise, while the others did not. We next used 1D and 2D uni-frequency patterns as stimuli in an attempt to reduce such variability in the judgment. The result showed, for higher frequency stimuli, sharpness decreased as the noise amount increased, while sharpness of the lower frequency stimuli increased at a certain noise level. From this result, we thought image noise might reduce sharpness at edges, but be able to improve sharpness of lower frequency component or texture in image. To prove this prediction, we experimented again with the natural image used in the first experiment. Stimuli were made by applying noise separately to edge or to texture part of the image. The result showed noise, when added to edge region, only decreased sharpness, whereas when added to texture, could improve sharpness. We think it is the interaction between noise and texture that sharpens image.

  11. Evidence for Bolgiano-Obukhov scaling in rotating stratified turbulence using high-resolution direct numerical simulations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Duane L; Pouquet, Dr. Annick; Mininni, Dr. Pablo D.

    2015-01-01

    We report results on rotating stratified turbulence in the absence of forcing, with large-scale isotropic initial conditions, using direct numerical simulations computed on grids of up tomore » $4096^3$ points. The Reynolds and Froude numbers are respectively equal to $$Re=5.4\\times 10^4$$ and $Fr=0.0242$$. The ratio of the Brunt-V\\"ais\\"al\\"a to the inertial wave frequency, $$N/f$, is taken to be equal to 5, a choice appropriate to model the dynamics of the southern abyssal ocean at mid latitudes. This gives a global buoyancy Reynolds number $$R_B=ReFr^2=32$$, a value sufficient for some isotropy to be recovered in the small scales beyond the Ozmidov scale, but still moderate enough that the intermediate scales where waves are prevalent are well resolved. We concentrate on the large-scale dynamics and confirm that the Froude number based on a typical vertical length scale is of order unity, with strong gradients in the vertical. Two characteristic scales emerge from this computation, and are identified from sharp variations in the spectral distribution of either total energy or helicity. A spectral break is also observed at a scale at which the partition of energy between the kinetic and potential modes changes abruptly, and beyond which a Kolmogorov-like spectrum recovers. Large slanted layers are ubiquitous in the flow in the velocity and temperature fields, and a large-scale enhancement of energy is also observed, directly attributable to the effect of rotation.« less

  12. The Molecular Structure of Phenetole Studied by Microwave Spectroscopy and Quantum Chemical Calculations

    NASA Astrophysics Data System (ADS)

    Ferres, Lynn; Stahl, Wolfgang; Nguyen, Ha Vinh Lam

    2016-06-01

    A pulsed molecular beam Fourier transform microwave spectrometer operating in the frequency range 2 - 26.5 GHz was used to measure the spectrum of phenetole (ethyl phenyl ether or ethoxybenzene, C6H5OC2H5). The conformational landscape is completely determined by the orientations of the phenyl ring and the ethyl group. A two-dimensional potential energy surface was calculated at the MP2/6-311++G(d,p) level of theory. Two conformers were found: The trans conformer has a Cs symmetry, and the gauche conformer has the ethyl group tilted out of the phenyl plane by about 70°. Totally 186 rotational transitions were assigned to the more stable planar trans conformer, and fitted using a semi-rigid rotor model to measurement accuracy of 2 kHz. Highly accurate rotational and centrifugal distortion constants were determined. Several method and basis set combinations were applied to check for convergence and to compare with the experimentally deduced molecular parameters. The inertial defect of the observed conformer Δc = (Ic - Ia - Ib) = -6.718 uÅ2 confirms that the heavy atom skeleton is planar with two pairs of hydrogen atoms out of plane. All lines in the spectrum could be assigned to the trans conformer, which confirms that the gauche conformer cannot be observed under our measurement conditions. In agreement with the rather high torsional barrier of the methyl group (V3 = 1168 wn) calculated by quantum chemical methods, all assigned lines appeared sharp and no signs of splittings were observed for the methyl internal rotation.

  13. Effect of composition gradient on magnetothermal instability modified by shear and rotation

    NASA Astrophysics Data System (ADS)

    Gupta, Himanshu; Chaudhuri, Anya; Sadhukhan, Shubhadeep; Chakraborty, Sagar

    2018-02-01

    We model the intracluster medium as a weakly collisional plasma that is a binary mixture of the hydrogen and the helium ions, along with free electrons. When, owing to the helium sedimentation, the gradient of the mean-molecular weight (or equivalently, composition or helium ions' concentration) of the plasma is not negligible, it can have appreciable influence on the stability criteria of the thermal convective instabilities, e.g. the heat-flux-buoyancy instability and the magnetothermal instability (MTI). These instabilities are consequences of the anisotropic heat conduction occurring preferentially along the magnetic field lines. In this paper, without ignoring the magnetic tension, we first present the mathematical criterion for the onset of composition gradient modified MTI. Subsequently, we relax the commonly adopted equilibrium state in which the plasma is at rest, and assume that the plasma is in a sheared state which may be due to differential rotation. We discuss how the concentration gradient affects the coupling between the Kelvin-Helmholtz instability and the MTI in rendering the plasma unstable or stable. We derive exact stability criterion by working with the sharp boundary case in which the physical variables - temperature, mean-molecular weight, density and magnetic field - change discontinuously from one constant value to another on crossing the boundary. Finally, we perform the linear stability analysis for the case of the differentially rotating plasma that is thermally and compositionally stratified as well. By assuming axisymmetric perturbations, we find the corresponding dispersion relation and the explicit mathematical expression determining the onset of the modified MTI.

  14. ROTATING ACCRETION FLOWS: FROM INFINITY TO THE BLACK HOLE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Jason; Ostriker, Jeremiah; Sunyaev, Rashid, E-mail: jgli@astro.princeton.edu

    2013-04-20

    Accretion onto a supermassive black hole of a rotating inflow is a particularly difficult problem to study because of the wide range of length scales involved. There have been broadly utilized analytic and numerical treatments of the global properties of accretion flows, but detailed numerical simulations are required to address certain critical aspects. We use the ZEUS code to run hydrodynamical simulations of rotating, axisymmetric accretion flows with Bremsstrahlung cooling, considering solutions for which the centrifugal balance radius significantly exceeds the Schwarzschild radius, with and without viscous angular momentum transport. Infalling gas is followed from well beyond the Bondi radiusmore » down to the vicinity of the black hole. We produce a continuum of solutions with respect to the single parameter M-dot{sub B}/ M-dot{sub Edd}, and there is a sharp transition between two general classes of solutions at an Eddington ratio of M-dot{sub B}/M-dot{sub Edd}{approx}few Multiplication-Sign 10{sup -2}. Our high inflow solutions are very similar to the standard Shakura and Sunyaev results. But our low inflow results are to zeroth order the stationary Papaloizou and Pringle solution, which has no accretion. To next order in the small, assumed viscosity they show circulation, with disk and conical wind outflows almost balancing inflow. These solutions are characterized by hot, vertically extended disks, and net accretion proceeds at an extremely low rate, only of order {alpha} times the inflow rate. Our simulations have converged with respect to spatial resolution and temporal duration, and they do not depend strongly on our choice of boundary conditions.« less

  15. Oscillation of the human ankle joint in response to applied sinusoidal torque on the foot

    PubMed Central

    Agarwal, Gyan C.; Gottlieb, Gerald L.

    1977-01-01

    1. Low-frequency (3-30 Hz) oscillatory rotation of the ankle joint in plantarflexion—dorsiflexion was generated with a torque motor. Torque, rotation about the ankle and electromyograms (e.m.g.s) for the gastrocnemius—soleus and the anterior tibial muscles were recorded. 2. Fourier coefficients at each drive frequency were used to calculate the effective compliance (ratio of rotation and torque). The compliance has a sharp resonance when tonic, voluntary muscle activity is present. 3. The resonant frequency of compliance is between 3 and 8 Hz. The location of the resonant frequency and the magnitude of the compliance at resonance depend upon both the degree of tonic muscle activity and the amplitude of the driving torque. The resonant frequency increases with increasing tonic activity. 4. With tonic muscle activity, the compliance in the frequency range below resonance increases with increasing amplitudes of driving torque. 5. The e.m.g., when evoked by the rhythmic stretch, lags the start of stretching by between 50 and 70 msec. 6. When tonic muscle activity is present, the resonant frequency of the stretch reflex is between 5 and 6·5 Hz. 7. Following the start of driven oscillation at frequencies near resonance, slowly increasing amplitudes of angular rotation (to a limit) are observed. 8. Distortion (from the sinusoidal wave shape) of angular rotation is frequently observed with drive frequencies between 8 and 12 Hz during which there sometimes occur spontaneous recurrences of oscillation at the drive frequency. For the angular rotation, a significant portion of the power may be in subharmonic frequency components of the drive frequency when that frequency is between 8 and 12 Hz. 9. Self-sustaining oscillation (clonus) near the resonant frequency of the compliance is sometimes observed after the modulation signal to the motor is turned off. This is most often seen when the gastrocnemius—soleus muscles are fatigued. Clonus may be evoked by driven oscillation at any frequency. 10. The hypothesis that physiological tremor, which occurs between 8 and 12 Hz, is a consequence of stretch reflex servo properties seems to be at odds with the observations of resonance in the compliance and of self-generated clonus both occurring in the 5-8 Hz region. PMID:874886

  16. Leg coordination during turning on an extremely narrow substrate in a bug, Mesocerus marginatus (Heteroptera, Coreidae).

    PubMed

    Frantsevich, Leonid I; Cruse, Holk

    2005-10-01

    The turning movement of a bug, Mesocerus marginatus, is observed when it walks upside-down below a horizontal beam and, at the end of the beam, performs a sharp turn by 180 degrees . The turn at the end of the beam is accomplished in three to five steps, without strong temporal coordination among legs. During the stance, leg endpoints (tarsi) run through rounded trajectories, rotating to the same side in all legs. During certain phases of the turn, a leg is strongly depressed and the tarsus crosses the midline. Swing movements rotate to the same side as do leg endpoints in stance, in strong contrast to the typical swing movements found in turns or straight walk on a flat surface. Terminal location is found after the search through a trajectory that first moves away from the body and then loops back to find substrate. When a leg during stance has crossed the midline, in the following swing movement the leg may move even stronger on the contralateral side, i.e. is stronger depressed, in contrast to swing movements in normal walking, where the leg is elevated. These results suggest that the animals apply a different control strategy compared to walking and turning on a flat surface.

  17. Structure and Properties of a Non-processive, Salt-requiring, and Acidophilic Pectin Methylesterase from Aspergillus niger Provide Insights into the Key Determinants of Processivity Control.

    PubMed

    Kent, Lisa M; Loo, Trevor S; Melton, Laurence D; Mercadante, Davide; Williams, Martin A K; Jameson, Geoffrey B

    2016-01-15

    Many pectin methylesterases (PMEs) are expressed in plants to modify plant cell-wall pectins for various physiological roles. These pectins are also attacked by PMEs from phytopathogens and phytophagous insects. The de-methylesterification by PMEs of the O6-methyl ester groups of the homogalacturonan component of pectin, exposing galacturonic acids, can occur processively or non-processively, respectively, describing sequential versus single de-methylesterification events occurring before enzyme-substrate dissociation. The high resolution x-ray structures of a PME from Aspergillus niger in deglycosylated and Asn-linked N-acetylglucosamine-stub forms reveal a 10⅔-turn parallel β-helix (similar to but with less extensive loops than bacterial, plant, and insect PMEs). Capillary electrophoresis shows that this PME is non-processive, halophilic, and acidophilic. Molecular dynamics simulations and electrostatic potential calculations reveal very different behavior and properties compared with processive PMEs. Specifically, uncorrelated rotations are observed about the glycosidic bonds of a partially de-methyl-esterified decasaccharide model substrate, in sharp contrast to the correlated rotations of processive PMEs, and the substrate-binding groove is negatively not positively charged. © 2016 by The American Society for Biochemistry and Molecular Biology, Inc.

  18. Advances in Non-contact Measurement of Creep Properties

    NASA Technical Reports Server (NTRS)

    Hyers, Robert W.; Canepari, Stacy; Rogers, Jan. R.

    2009-01-01

    Our team has developed a novel approach to measuring creep at extremely high temperatures using electrostatic levitation (ESL). This method has been demonstrated on niobium up to 2300 C, while ESL has melted tungsten (3400 C). High-precision machined spheres of the sample are levitated in the NASA MSFC ESL, a national user facility, and heated with a laser. The laser is aligned off-center so that the absorbed photons transfer their momentum to the sample, causing it to rotate at up to 250,000+ RPM. The rapid rotation loads the sample through centripetal acceleration, causing it to deform. The deformation of the sample is captured on high-speed video, which is analyzed by machine-vision software from the University of Massachusetts. The deformations are compared to finite element models to determine the constitutive constants in the creep relation. Furthermore, the noncontact method exploits stress gradients within the sample to determine the stress exponent in a single test. This method was validated in collaboration with the University of Tennessee for niobium at 1985 C, with agreement within the uncertainty of the conventional measurements. A similar method is being employed on Ultra-High-Temperature ZrB2- SiC composites, which may see application in rocket nozzles and sharp leading edges for hypersonic vehicles.

  19. Isolation, characterization, and complementation of a motility mutant of Spiroplasma citri.

    PubMed Central

    Jacob, C; Nouzières, F; Duret, S; Bové, J M; Renaudin, J

    1997-01-01

    The helical mollicute Spiroplasma citri, when growing on low-agar medium, forms fuzzy colonies with occasional surrounding satellite colonies due to the ability of the spiroplasmal cells to move through the agar matrix. In liquid medium, these helical organisms flex, twist, and rotate rapidly. By using Tn4001 insertion mutagenesis, a motility mutant was isolated on the basis of its nondiffuse, sharp-edged colonies. Dark-field microscopy observations revealed that the organism flexed at a low frequency and had lost the ability to rotate about the helix axis. In this mutant, the transposon was shown to be inserted into an open reading frame encoding a putative polypeptide of 409 amino acids for which no significant homology with known proteins was found. The corresponding gene, named scm1, was recovered from the wild-type strain and introduced into the motility mutant by using the S. citri oriC plasmid pBOT1 as the vector. The appearance of fuzzy colonies and the observation that spiroplasma cells displayed rotatory and flexional movements showed the motile phenotype to be restored in the spiroplasmal transformants. The functional complementation of the motility mutant proves the scm1 gene product to be involved in the motility mechanism of S. citri. PMID:9244268

  20. Quantum theory of rotational isomerism and Hill equation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ugulava, A.; Toklikishvili, Z.; Chkhaidze, S.

    2012-06-15

    The process of rotational isomerism of linear triatomic molecules is described by the potential with two different-depth minima and one barrier between them. The corresponding quantum-mechanical equation is represented in the form that is a special case of the Hill equation. It is shown that the Hill-Schroedinger equation has a Klein's quadratic group symmetry which, in its turn, contains three invariant subgroups. The presence of these subgroups makes it possible to create a picture of energy spectrum which depends on a parameter and has many merging and branch points. The parameter-dependent energy spectrum of the Hill-Schroedinger equation, like Mathieu-characteristics, containsmore » branch points from the left and from the right of the demarcation line. However, compared to the Mathieu-characteristics, in the Hill-Schroedinger equation spectrum the 'right' points are moved away even further for some distance that is the bigger, the bigger is the less deep well. The asymptotic wave functions of the Hill-Schroedinger equation for the energy values near the potential minimum contain two isolated sharp peaks indicating a possibility of the presence of two stable isomers. At high energy values near the potential maximum, the height of two peaks decreases, and between them there appear chaotic oscillations. This form of the wave functions corresponds to the process of isomerization.« less

  1. Spin Vector and Shape of (6070) Rheinland and Their Implications

    NASA Astrophysics Data System (ADS)

    Vokrouhlický, David; Ďurech, Josef; Polishook, David; Krugly, Yurij N.; Gaftonyuk, Ninel N.; Burkhonov, Otabek A.; Ehgamberdiev, Shukhrat A.; Karimov, Rivkat; Molotov, Igor E.; Pravec, Petr; Hornoch, Kamil; Kušnirák, Peter; Oey, Julian; Galád, Adrián; Žižka, Jindřich

    2011-11-01

    Main belt asteroids (6070) Rheinland and (54827) 2001 NQ8 belong to a small population of couples of bodies that reside in very similar heliocentric orbits. Vokrouhlický & Nesvorný promoted the term "asteroid pairs," pointing out their common origin within the past tens to hundreds of kyr. Previous attempts to reconstruct the initial configuration of Rheinland and 2001 NQ8 at the time of their separation have led to the prediction that Rheinland's rotation should be retrograde. Here, we report extensive photometric observations of this asteroid and use the light curve inversion technique to directly determine its rotation state and shape. We confirm the retrograde sense of rotation of Rheinland, with obliquity value constrained to be >=140°. The ecliptic longitude of the pole position is not well constrained as yet. The asymmetric behavior of Rheinland's light curve reflects a sharp, near-planar edge in our convex shape representation of this asteroid. Our calibrated observations in the red filter also allow us to determine HR = 13.68 ± 0.05 and G = 0.31 ± 0.05 values of the H-G system. With the characteristic color index V - R = 0.49 ± 0.05 for S-type asteroids, we thus obtain H = 14.17 ± 0.07 for the absolute magnitude of (6070) Rheinland. This is a significantly larger value than previously obtained from analysis of astrometric survey observations. We next use the obliquity constraint for Rheinland to eliminate some degree of uncertainty in the past propagation of its orbit. This is because the sign of the past secular change of its semimajor axis due to the Yarkovsky effect is now constrained. The determination of the rotation state of the secondary component, asteroid (54827) 2001 NQ8, is the key element in further constraining the age of the pair and its formation process.

  2. IUE and Einstein survey of late-type giant and supergiant stars and the dividing line

    NASA Technical Reports Server (NTRS)

    Haisch, Bernhard M.; Bookbinder, Jay A.; Maggio, A.; Vaiana, G. S.; Bennett, Jeffrey O.

    1990-01-01

    Results are presented on an IUE UV survey of 255 late-type G, K, and M stars, complementing the Maggio et al. (1990) Einstein X-ray survey of 380 late-type stars. The large data sample of X-ray and UV detections make it possible to examine the activity relationship between the X-ray and the UV emissions. The results confirm previous finding of a trend involving a steeply-dropping upper envelope of the transition region line fluxes, f(line)/f(V), as the dividing line is approached. This suggests that a sharp decrease in maximum activity accompanies the advancing spectral type, with the dividing line corresponding to this steep gradient region. The results confirm the rotation-activity connection for stars in this region of the H-R diagram.

  3. The importance of cantilever dynamics in the interpretation of Kelvin probe force microscopy.

    PubMed

    Satzinger, Kevin J; Brown, Keith A; Westervelt, Robert M

    2012-09-15

    A realistic interpretation of the measured contact potential difference (CPD) in Kelvin probe force microscopy (KPFM) is crucial in order to extract meaningful information about the sample. Central to this interpretation is a method to include contributions from the macroscopic cantilever arm, as well as the cone and sharp tip of a KPFM probe. Here, three models of the electrostatic interaction between a KPFM probe and a sample are tested through an electrostatic simulation and compared with experiment. In contrast with previous studies that treat the KPFM cantilever as a rigid object, we allow the cantilever to bend and rotate; accounting for cantilever bending provides the closest agreement between theory and experiment. We demonstrate that cantilever dynamics play a major role in CPD measurements and provide a simulation technique to explore this phenomenon.

  4. Simulating the interaction of the heliosphere with the local interstellar medium: MHD results from a finite volume approach, first bidimensional results

    NASA Technical Reports Server (NTRS)

    Chanteur, G.; Khanfir, R.

    1995-01-01

    We have designed a full compressible MHD code working on unstructured meshes in order to be able to compute accurately sharp structures embedded in large scale simulations. The code is based on a finite volume method making use of a kinetic flux splitting. A bidimensional version of the code has been used to simulate the interaction of a moving interstellar medium, magnetized or unmagnetized with a rotating and magnetized heliopspheric plasma source. Being aware that these computations are not realistic due to the restriction to two dimensions, we present it to demonstrate the ability of this new code to handle this problem. An axisymetric version, now under development, will be operational in a few months. Ultimately we plan to run a full 3d version.

  5. Non-Zhang-Rice Singlet Character of the First Ionization State of T-CuO

    NASA Astrophysics Data System (ADS)

    Adolphs, Clemens P. J.; Moser, Simon; Sawatzky, George A.; Berciu, Mona

    2016-02-01

    We argue that tetragonal CuO (T-CuO) has the potential to finally settle long-standing modeling issues for cuprate physics. We compare the one-hole quasiparticle (qp) dispersion of T-CuO to that of cuprates, in the framework of the strongly correlated (Ud d→∞ ) limit of the three-band Emery model. Unlike in CuO2 , magnetic frustration in T-CuO breaks the C4 rotational symmetry and leads to strong deviations from the Zhang-Rice singlet picture in parts of the reciprocal space. Our results are consistent with angle-resolved photoemission spectroscopy data but in sharp contradiction to those of a one-band model previously suggested for them. These differences identify T-CuO as an ideal material to test a variety of scenarios proposed for explaining cuprate phenomenology.

  6. Sharps Injuries and Other Blood and Body Fluid Exposures Among Home Health Care Nurses and Aides

    PubMed Central

    Markkanen, Pia K.; Galligan, Catherine J.; Kriebel, David; Chalupka, Stephanie M.; Kim, Hyun; Gore, Rebecca J.; Sama, Susan R.; Laramie, Angela K.; Davis, Letitia

    2009-01-01

    Objectives. We quantified risks of sharp medical device (sharps) injuries and other blood and body fluid exposures among home health care nurses and aides, identified risk factors, assessed the use of sharps with safety features, and evaluated underreporting in workplace-based surveillance. Methods. We conducted a questionnaire survey and workplace-based surveillance, collaborating with 9 home health care agencies and 2 labor unions from 2006 to 2007. Results. Approximately 35% of nurses and 6.4% of aides had experienced at least 1 sharps injury during their home health care career; corresponding figures for other blood and body fluid exposures were 15.1% and 6.7%, respectively. Annual sharps injuries incidence rates were 5.1 per 100 full-time equivalent (FTE) nurses and 1.0 per 100 FTE aides. Medical procedures contributing to sharps injuries were injecting medications, administering fingersticks and heelsticks, and drawing blood. Other contributing factors were sharps disposal, contact with waste, and patient handling. Sharps with safety features frequently were not used. Underreporting of sharps injuries to the workplace-based surveillance system was estimated to be about 50%. Conclusions. Sharps injuries and other blood and body fluid exposures are serious hazards for home health care nurses and aides. Improvements in hazard intervention are needed. PMID:19890177

  7. Needlestick and Sharps Injuries in Dermatologic Surgery: A Review of Preventative Techniques and Post-exposure Protocols

    PubMed Central

    Monroe, Holly; Orengo, Ida; Rosen, Theodore

    2016-01-01

    Background: Needlestickand sharps injuries are the leading causes of morbidity in the dermatologicfield. Among medical specialties, surgeons and dermatologists have the highest rates of needlestickand sharps injuries.The high rates of needlestickand sharps injuries in dermatology not only apply to physicians, but also to nurses, physician assistants, and technicians in the demnatologic field. Needlestickand sharps injuries are of great concern due to the monetary, opportunity, social, and emotional costs associated with their occurrence. Objective: A review of preventative techniques and post-exposure protocols for the majortypes of sharps injuries encountered in dermatologic practice. Design: The terms “needle-stick injuryT’sharps injuryTdermatologic surgery? “post-exposure prophylaxis,”and “health-care associated injury” were used in combinations to search the PubMed database. Relevant studies were reviewed for validity and included. Results The authors discuss the major types of sharps injuries that occur in the dermatologic surgery setting and summarize preventative techniques with respect to each type of sharps injury.The authors also summarize and discuss relevant post-exposure protocols in the event of a sharps injury. Conclusion: The adoption of the discussed methods, techniques, practices, and attire can result in the elimination of the vast majority of dermatologic sharps injuries. PMID:27847548

  8. Analysis and Optimization of the Production Process of Cooked Sausage Meat Matrices

    NASA Astrophysics Data System (ADS)

    Diez, L.; Rauh, C.; Delgado, A.

    2010-09-01

    In the production of cooked sausages a critical step for product quality is the cutting process, where the comminuting and mixing of meat, fat, ice and spices are carried out. These processes take usually place in bowl cutters, which main control parameters are the working time, knife geometry (shape and sharpness) and rotational velocities of the knives and the bowl. The choice of the geometry and sharpness of the knives influences not only the meat matrix properties (mechanical, rheological, etc.) and, as a consequence, the sensory value of the sausages (size of connective tissue particles, water binding, etc.), but also the energetic demand for the production. However, the cutting process proves to be understood only fragmentarily due to the complex colloid chemical and mechanical behavior of the product. This is documented on the one hand by numerous knife types on the market, extremely empirical approach during determination of geometry and process parameters in practice as well as, on the other hand, by contradictory statements and explanation approaches of observed phenomena present in literature. The present contribution applies numerical simulations to analyze thermo fluid mechanical phenomena, e.g. shear stresses, during the cutting process of the non-Newtonian meat matrix. Combining these results with selected experimental investigations from literature, e.g. sensory properties, knife geometry, velocity of the knife and bowl, improvements of the cutting and mixing process are proposed using cognitive algorithms (Artificial neural networks) aiming at an optimization regarding energy and time demand and product quality.

  9. Relationship between Bruxism and Malocclusion among Preschool Children in Isfahan

    PubMed Central

    Ghafournia, Maryam; Hajenourozali Tehrani, Maryam

    2012-01-01

    Background and aims Bruxism is defined as a habitual nonfunctional forceful contact between occlusal tooth surfaces. In younger children bruxism may be a consequence of the masticatory neuromuscular system immaturity. The aim of this study was to assess the prevalence of bruxism and investigate the relationship between occlusal factors and bruxism among preschool children. Materials and methods In this cross-sectional survey, 400 3-6-year-old children were selected randomly from different preschools in Isfahan, Iran. The subjects were divided into two groups of bruxers and non-bruxers as determined by the clinical examination and their parents’ reports. The examiner recorded the primary canines (Class I, Class II, and Class III) and molars (mesial step, distal step, flash terminal plane) relationship, existence of anterior and posterior crossbite, open and deep bite. Also, rotated teeth, food impaction, sharp tooth edges, high restorations, extensive tooth caries, and painful teeth (categorized as irritating tooth conditions) were evaluated. The relationship between bruxism and occlusal factors and irritating tooth conditions was evaluated with chi-square test. Results Bruxism was seen in 12.75% of the subjects. Statistically significant relationships existed between bruxism and some occlusal factors, such as flash terminal plane (P = 0.023) and mesial step (P = 0.001) and also, between food impaction, extensive tooth caries, tooth pain, sharp tooth edge and bruxism. Conclusion The results showed significant relationship of bruxism with primary molar relationships and irritating tooth conditions among preschool children. PMID:23277860

  10. Spacecraft Health Automated Reasoning Prototype (SHARP): The fiscal year 1989 SHARP portability evaluations task for NASA Solar System Exploration Division's Voyager project

    NASA Technical Reports Server (NTRS)

    Atkinson, David J.; Doyle, Richard J.; James, Mark L.; Kaufman, Tim; Martin, R. Gaius

    1990-01-01

    A Spacecraft Health Automated Reasoning Prototype (SHARP) portability study is presented. Some specific progress is described on the portability studies, plans for technology transfer, and potential applications of SHARP and related artificial intelligence technology to telescience operations. The application of SHARP to Voyager telecommunications was a proof-of-capability demonstration of artificial intelligence as applied to the problem of real time monitoring functions in planetary mission operations. An overview of the design and functional description of the SHARP system is also presented as it was applied to Voyager.

  11. Flow and Heat Transfer in 180-Degree Turn Square Ducts: Effects of Turning Configuration and System Rotation

    NASA Technical Reports Server (NTRS)

    Wang, Ten-See; Chyu, Ming-King

    1993-01-01

    Forced flow through channels connected by sharp bends is frequently encountered in various rocket and gas turbine engines. For example, the transfer ducts, the coolant channels surround the combustion chamber, the internal cooling passage in a blade or vane, the flow path in the fuel element of a nuclear rocket engine, the flow around a pressure relieve valve piston, and the recirculated base flow of multiple engine clustered nozzles. Transport phenomena involved in such a flow passage are complex and considered to be very different from those of conventional turning flow with relatively mild radii of curvature. While previous research pertaining to this subject has been focused primarily on the experimental heat transfer, very little analytical work is directed to understanding the flowfield and energy transport in the passage. Therefore, the primary goal of this paper is to benchmark the predicted wall heat fluxes using a state-of-the-art computational fluid dynamics (CFD) formulation against those of measurement for a rectangular turn duct. Other secondary goals include studying the effects of turning configurations, e.g., the semi-circular turn, and the rounded-corner turn, and the effect of system rotation. The computed heat fluxes for the rectangular turn duct compared favorably with those of the experimental data. The results show that the flow pattern, pressure drop, and heat transfer characteristics are different among the three turning configurations, and are substantially different with system rotation. Also demonstrated in this work is that the present computational approach is quite effective and efficient and will be suitable for flow and thermal modeling in rocket and turbine engine applications.

  12. High-Resolution Faraday Rotation and Electron-Phonon Coupling in Surface States of the Bulk-Insulating Topological Insulator Cu_{0.02}Bi_{2}Se_{3}.

    PubMed

    Wu, Liang; Tse, Wang-Kong; Brahlek, M; Morris, C M; Aguilar, R Valdés; Koirala, N; Oh, S; Armitage, N P

    2015-11-20

    We have utilized time-domain magnetoterahertz spectroscopy to investigate the low-frequency optical response of the topological insulator Cu_{0.02}Bi_{2}Se_{3} and Bi_{2}Se_{3} films. With both field and frequency dependence, such experiments give sufficient information to measure the mobility and carrier density of multiple conduction channels simultaneously. We observe sharp cyclotron resonances (CRs) in both materials. The small amount of Cu incorporated into the Cu_{0.02}Bi_{2}Se_{3} induces a true bulk insulator with only a single type of conduction with a total sheet carrier density of ~4.9×10^{12}/cm^{2} and mobility as high as 4000 cm^{2}/V·s. This is consistent with conduction from two virtually identical topological surface states (TSSs) on the top and bottom of the film with a chemical potential ~145 meV above the Dirac point and in the bulk gap. The CR broadens at high fields, an effect that we attribute to an electron-phonon interaction. This assignment is supported by an extended Drude model analysis of the zero-field Drude conductance. In contrast, in normal Bi_{2}Se_{3} films, two conduction channels were observed, and we developed a self-consistent analysis method to distinguish the dominant TSSs and coexisting trivial bulk or two-dimensional electron gas states. Our high-resolution Faraday rotation spectroscopy on Cu_{0.02}Bi_{2}Se_{3} paves the way for the observation of quantized Faraday rotation under experimentally achievable conditions to push the chemical potential in the lowest Landau level.

  13. Midlatitude D region variations measured from broadband radio atmospherics

    NASA Astrophysics Data System (ADS)

    Han, Feng

    The high power, broadband very low frequency (VLF, 3--30 kHz) and extremely low frequency (ELF, 3--3000 Hz) electromagnetic waves generated by lightning discharges and propagating in the Earth-ionosphere waveguide can be used to measure the average electron density profile of the lower ionosphere (D region) across the wave propagation path due to several reflections by the upper boundary (lower ionosphere) of the waveguide. This capability makes it possible to frequently and even continuously monitor the D region electron density profile variations over geographically large regions, which are measurements that are essentially impossible by other means. These guided waves, usually called atmospherics (or sferics for short), are recorded by our sensors located near Duke University. The purpose of this work is to develop and implement algorithms to derive the variations of D region electron density profile which is modeled by two parameters (one is height and another is sharpness), by comparing the recorded sferic spectra to a series of model simulated sferic spectra from using a finite difference time domain (FDTD) code. In order to understand the time scales, magnitudes and sources for the midlatitude nighttime D region variations, we analyzed the sferic data of July and August 2005, and extracted both the height and sharpness of the D region electron density profile. The heights show large temporal variations of several kilometers on some nights and the relatively stable behavior on others. Statistical calculations indicate that the hourly average heights during the two months range between 82.0 km and 87.2 km with a mean value of 84.9 km and a standard deviation of 1.1 km. We also observed spatial variations of height as large as 2.0 km over 5 degrees latitudes on some nights, and no spatial variation on others. In addition, the measured height variations exhibited close correlations with local lightning occurrence rate on some nights but no correlation with local lightning or displaced lightning on others. The nighttime profile sharpness during 2.5 hours in two different nights was calculated, and the results were compared to the equivalent sharpness derived from International Reference Ionosphere (IRI) models. Both the absolute values and variation trends in IRI models are different from those in broadband measurements. Based on sferic data similar to those for nighttime, we also measured the day-time D region electron density profile variations in July and August 2005 near Duke University. As expected, the solar radiation is the dominant but not the only determinant source for the daytime D region profile height temporal variations. The observed quiet time heights showed close correlations with solar zenith angle changes but unexpected spatial variations not linked to the solar zenith angle were also observed on some days, with 15% of days exhibiting regional differences larger than 0.5 km. During the solar flare, the induced height change was approximately proportional to the logarithm of the X-ray fluxes. During the rising and decaying phases of the solar flare, the height changes correlated more consistently with the short (wavelength 0.5--4 A), rather than the long (wavelength 1--8 A) X-ray flux changes. The daytime profile sharpness during morning, noontime and afternoon periods in three different days and for the solar zenith angle range 20 to 75 degrees was calculated. These broadband measured results were compared to narrowband VLF measurements, IRI models and Faraday rotation base IRI models (called FIRI). The estimated sharpness from all these sources was more consistent when the solar zenith angle was small than when it was large. By applying the nighttime and daytime measurement techniques, we also derived the D region variations during sunrise and sunset periods. The measurements showed that both the electron density profile height and sharpness decrease during the sunrise period while increase during the sunset period.

  14. Resistivity of Rotated Graphite-Graphene Contacts.

    PubMed

    Chari, Tarun; Ribeiro-Palau, Rebeca; Dean, Cory R; Shepard, Kenneth

    2016-07-13

    Robust electrical contact of bulk conductors to two-dimensional (2D) material, such as graphene, is critical to the use of these 2D materials in practical electronic devices. Typical metallic contacts to graphene, whether edge or areal, yield a resistivity of no better than 100 Ω μm but are typically >10 kΩ μm. In this Letter, we employ single-crystal graphite for the bulk contact to graphene instead of conventional metals. The graphite contacts exhibit a transfer length up to four-times longer than in conventional metallic contacts. Furthermore, we are able to drive the contact resistivity to as little as 6.6 Ω μm(2) by tuning the relative orientation of the graphite and graphene crystals. We find that the contact resistivity exhibits a 60° periodicity corresponding to crystal symmetry with additional sharp decreases around 22° and 39°, which are among the commensurate angles of twisted bilayer graphene.

  15. Visualizing polarization singularities in Bessel-Poincaré beams.

    PubMed

    Shvedov, V; Karpinski, P; Sheng, Y; Chen, X; Zhu, W; Krolikowski, W; Hnatovsky, C

    2015-05-04

    We demonstrate that an annulus of light whose polarization is linear at each point, but the plane of polarization gradually rotates by π radians can be used to generate Bessel-Poincaré beams. In any transverse plane this beam exhibits concentric rings of polarization singularities in the form of L-lines, where the polarization is purely linear. Although the L-lines are invisible in terms of light intensity variations, we present a simple way to visualize them as dark rings around a sharp peak of intensity in the beam center. To do this we use a segmented polarizer whose transmission axes are oriented differently in each segment. The radius of the first L-line is always smaller than the radius of the central disk of the zero-order Bessel beam that would be produced if the annulus were homogeneously polarized and had no phase circulation along it.

  16. The dynamical role of the central molecular ring within the framework of a seven-component Galaxy model

    NASA Astrophysics Data System (ADS)

    Simin, A. A.; Fridman, A. M.; Haud, U. A.

    1991-09-01

    A Galaxy model in which the surface density of the gas component has a sharp (two orders of magnitude) jump in the region of the outer radius of the molecular ring is constructed on the basis of observational data. This model is used to calculate the contributions of each population to the model curve of Galactic rotation. The value of the dimensionless increment of hydrodynamical instability for the gas component, being much less than 1, coincides with a similar magnitude for the same gas in the gravity field of the entire Galaxy. It is concluded that the unstable gas component of the Galaxy lies near the limit of the hydrodynamical instability, which is in accordance with the Le Chatelier principle. The stellar populations of the Galaxy probably do not affect the generation of the spiral structure in the gaseous component.

  17. Color View of Ceres

    NASA Technical Reports Server (NTRS)

    2005-01-01

    This is a NASA Hubble Space Telescope color image of Ceres, the largest object in the asteroid belt.

    Astronomers enhanced the sharpness in these Advanced Camera for Surveys images to bring out features on Ceres' surface, including brighter and darker regions that could be asteroid impact features. The observations were made in visible and ultraviolet light between December 2003 and January 2004.

    The colors represent the differences between relatively red and blue regions. These differences may simply be due to variation on the surface among different types of material.

    Ceres' round shape suggests that its interior is layered like those of terrestrial planets such as Earth. Ceres may have a rocky inner core, an icy mantle, and a thin, dusty outer crust inferred from its density and rotation rate of 9 hours. Ceres is approximately 590 miles (950 kilometers) across and was first discovered in 1801.

  18. Membrane-less variable focus liquid lens with manual actuation

    NASA Astrophysics Data System (ADS)

    Patra, Roshan; Agarwal, Shivam; Kondaraju, Sasidhar; Bahga, Supreet Singh

    2017-04-01

    We present a tunable, membrane-less, mechanical-wetting liquid lens that can be actuated manually using a linear actuator such as screw or piston. The operation of the liquid lens is based on deforming the interface separating two immiscible liquids with different refractive indices, while pinning the three-phase contact line at the sharp edge of lens aperture. Our lens design improves upon the existing designs of mechanical-wetting lenses by eliminating the use of complex actuation mechanisms, without compromising on the optical performance. We demonstrate the operation of the liquid lens by tuning its power back and forth from negative to positive by simple rotation of a screw. We also present an analytical description of the focal length of the lens and validate it with detailed experimental measurements. Our experiments show that the focal length of the liquid lens can be tuned repeatably without any adverse effects of hysteresis and gravity.

  19. Process development of starch hydrolysis using mixing characteristics of Taylor vortices.

    PubMed

    Masuda, Hayato; Horie, Takafumi; Hubacz, Robert; Ohmura, Naoto; Shimoyamada, Makoto

    2017-04-01

    In food industries, enzymatic starch hydrolysis is an important process that consists of two steps: gelatinization and saccharification. One of the major difficulties in designing the starch hydrolysis process is the sharp change in its rheological properties. In this study, Taylor-Couette flow reactor was applied to continuous starch hydrolysis process. The concentration of reducing sugar produced via enzymatic hydrolysis was evaluated by varying operational variables: rotational speed of the inner cylinder, axial velocity (reaction time), amount of enzyme, and initial starch content in the slurry. When Taylor vortices were formed in the annular space, efficient hydrolysis occurred because Taylor vortices improved the mixing of gelatinized starch with enzyme. Furthermore, a modified inner cylinder was proposed, and its mixing performance was numerically investigated. The modified inner cylinder showed higher potential for enhanced mixing of gelatinized starch and the enzyme than the conventional cylinder.

  20. Large Eddy Simulation of Ducted Propulsors in Crashback

    NASA Astrophysics Data System (ADS)

    Jang, Hyunchul; Mahesh, Krishnan

    2009-11-01

    Flow around a ducted marine propulsor is computed using the large eddy simulation methodology under crashback conditions. Crashback is an operating condition where a propulsor rotates in the reverse direction while the vessel moves in the forward direction. It is characterized by massive flow separation and highly unsteady propeller loads, which affect both blade life and maneuverability. The simulations are performed on unstructured grids using the discrete kinetic energy conserving algorithm developed by Mahesh at al. (2004, J. Comput. Phys 197). Numerical challenges posed by sharp blade edges and small blade tip clearances are discussed. The flow is computed at the advance ratio J=-0.7 and Reynolds number Re=480,000 based on the propeller diameter. Average and RMS values of the unsteady loads such as thrust, torque, and side force on the blades and duct are compared to experiment, and the effect of the duct on crashback is discussed.

  1. Sensitive bistable magnetic sensors using twisted amorphous magnetostrictive ribbons due to Matteucci effect

    NASA Astrophysics Data System (ADS)

    Mohri, K.; Takeuchi, S.

    1982-11-01

    New sensitive magnetic-field sensors are presented using twisted amorphous magnetostrictive ribbons such as Fe80B20 and Fe81-xCrxB17Si2. Sharp voltage pulses are induced between ends of the ribbon of as short as 25 mm or at the terminals of the detecting coil against external fields of as low as 1 Oe and 0.01 Hz-6 kHz. The domain nucleation field at the bistable flux reversal is very constant for 130 °C, 600 h using Fe79Cr2B17Si2, and a possible maximum operating temperature is about 180 °C. Small sized magnetic sensors without any windings for detecting rotational speed, distance, and other mechanical quantities are realized using the twisted ribbons by combining with small magnets. These sensitive and reliable magnetic sensors with digital outputs are suitable for applications in industrial robots and automobiles controlled with microcomputers.

  2. Magnetic properties of permalloy wires in vycor capillaries

    NASA Astrophysics Data System (ADS)

    Lubitz, P.; Ayers, J. D.; Davis, A.

    1991-11-01

    Thin wires of NiFe alloys with compositions near 80% Ni were prepared by melting the alloy in vycor tubes and drawing fibers from the softened glass. The resulting fibers consist of relatively thick-walled vycor capillaries containing permalloy wires filling a few percent of the volume. The wires are continuous over considerable lengths, uniform in circular cross section, nearly free of contact with the walls and can be drawn to have diameters less than 1 μm. Their magnetic properties are generally similar to bulk permalloy, but show a variety of magnetic switching behaviors for fields along the wire axis, depending on composition, wire diameter, and thermal history. As pulled, the wires can show sharp switching, reversible rotation or mixed behavior. This method can produce NiFe alloy wires suitable for use in applications as sensor, memory or inductive elements; other alloys, such as supermalloy and sendust, also can be fabricated as fine wires by this method.

  3. THE OUTBURST OF THE BLAZAR S5 0716+71 IN 2011 OCTOBER: SHOCK IN A HELICAL JET

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larionov, V. M.; Jorstad, S. G.; Morozova, D. A.

    We present the results of optical (R band) photometric and polarimetric monitoring and Very Long Baseline Array (VLBA) imaging of the blazar S5 0716+714 along with Fermi {gamma}-ray data during a multi-waveband outburst in 2011 October. We analyze total and polarized intensity images of the blazar obtained with the VLBA at 43 GHz during and after the outburst. Monotonic rotation of the linear polarization vector at a rate of {approx}> 50 Degree-Sign per night coincided with a sharp maximum in {gamma}-ray and optical flux. At the same time, within the uncertainties, a new superluminal knot appeared with an apparent speedmore » of 21 {+-} 2c. The general multi-frequency behavior of the outburst can be explained within the framework of a shock wave propagating along a helical path in the blazar's jet.« less

  4. Study of A-site doping of SrBi4Ti4O15 Bi-layered compounds using micro-Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Hao, H.; Liu, H. X.; Cao, M. H.; Min, X. M.; Ouyang, S. X.

    2006-10-01

    The temperature-dependent Raman spectra of Mg- and La-doped SrBi4Ti4O15 (SBT) were studied in the range 40 590 °C. A quantum chemistry calculation was employed to estimate these two substitution states. It was found that A-site doping in this study not only caused multiplicative substitution states, but also the Raman spectra changed with the substitution amount. In a La-doped perovskite-like layer, La would occupy the Bi site when x>0.10 and the 314 and 550 cm-1 modes related to the rotating and tilting of the TiO6 octahedron firstly became wide and then became sharp. With the increase of the substitution amount, both substitution states of Mg-doped SBT lead to the widening of 270 and 520 cm-1 peaks.

  5. Physical Orbit for Lam Vir and Testing of Stellar Evolution Models

    NASA Astrophysics Data System (ADS)

    Zhao, M.; Monnier, J. D.; Torres, G.; Pedretti, E.; Millan-Gabet, R.; Berger, J.-P.; Traub, W. A.; Schloerb, F. P.

    2005-12-01

    Lambda Virginis is a well-known double-lined spectroscopic Am binary with the interesting property that both stars are very similar in abundance but one is sharp-lined and the other is broad-lined. The differing rotation rates and the unusual metallic-lined nature of this system presents a unique opportunity to test stellar evolution models. In this poster, we present high resolution observations of Lam Vir, taken with the Infrared-Optical Telescopes Array (IOTA) between 2003 and 2005. By combining our interferometric data with double-lined radial velocity data, we determined for the first time the physical orbit of Lam Vir, as well as the orbital parallax of the system. In addition, the masses of the two components are determined with 1% and 1.5% errors respectively. Our preliminary result from comparison with stellar evolution models suggests a discrepancy between Lam Vir and standard models.

  6. Autoresonant Control of Elliptical Non-neutral Plasmas

    NASA Astrophysics Data System (ADS)

    Friedland, Lazar

    1999-11-01

    It is shown that placing a magnetized non-neutral plasma column in a weak oscillating transverse quadrupolar potential with chirped oscillation frequency allows excitation and control of the ellipticity and rotation phase of the plasma cross section. For a given chirp rate of the driving frequency, the phenomenon has a sharp threshold on the amplitude of the perturbing potential. The effect is analogous to that reported in controlling Kirchhoff vortices in fluid dynamics [1]. The ellipticity of the plasma cross section is manipulated by using autoresonance (nonlinear phase locking) in the system between the ExB drifting plasma particles and adiabatically varying driving potential. A similar idea was used recently in controlling the l=1 diocotron mode in a non-neutral plasma [2]. [1] L. Friedland, Phys. Rev. E59, 4106 (1999). [2] J. Fajans, E. Gilson, and L. Friedland, Phys. Rev. Lett. 82, 4444 (1999).

  7. Ferromagnetism and superconductivity in CeFeAs1-xPxO (0⩽x⩽40)

    NASA Astrophysics Data System (ADS)

    Jesche, A.; Förster, T.; Spehling, J.; Nicklas, M.; de Souza, M.; Gumeniuk, R.; Luetkens, H.; Goltz, T.; Krellner, C.; Lang, M.; Sichelschmidt, J.; Klauss, H.-H.; Geibel, C.

    2012-07-01

    We report on superconductivity in CeFeAs1-xPxO and the possible coexistence with Ce ferromagnetism (FM) in a small homogeneity range around x=30% with ordering temperatures of TSC≅TC≅4 K. The antiferromagnetic (AFM) ordering temperature of Fe at this critical concentration is suppressed to TNFe≈40 K and does not shift to lower temperatures with a further increase of the P concentration. Therefore, a quantum-critical-point scenario with TNFe→0 K which is widely discussed for the iron based superconductors can be excluded for this alloy series. Surprisingly, thermal expansion and x-ray powder diffraction indicate the absence of an orthorhombic distortion despite clear evidence for short-range AFM Fe ordering from muon-spin-rotation measurements. Furthermore, we discovered the formation of a sharp electron spin resonance signal unambiguously connected with the emergence of FM ordering.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jesche, A.; Förster, T.; Spehling, J.

    We report on superconductivity in CeFeAs 1-xP xO and the possible coexistence with Ce ferromagnetism (FM) in a small homogeneity range around x=30% with ordering temperatures of T SC≅T C≅4 K. The antiferromagnetic (AFM) ordering temperature of Fe at this critical concentration is suppressed to Tmore » $$Fe\\atop{N}$$≈40 K and does not shift to lower temperatures with a further increase of the P concentration. Therefore, a quantum-critical-point scenario with T$$Fe\\atop{N}$$→0 K which is widely discussed for the iron based superconductors can be excluded for this alloy series. Surprisingly, thermal expansion and x-ray powder diffraction indicate the absence of an orthorhombic distortion despite clear evidence for short-range AFM Fe ordering from muon-spin-rotation measurements. Furthermore, we discovered the formation of a sharp electron spin resonance signal unambiguously connected with the emergence of FM ordering.« less

  9. Incidence, Determinants, and Outcomes of Coronary Perforation During Percutaneous Coronary Intervention in the United Kingdom Between 2006 and 2013: An Analysis of 527 121 Cases From the British Cardiovascular Intervention Society Database.

    PubMed

    Kinnaird, Tim; Kwok, Chun Shing; Kontopantelis, Evangelos; Ossei-Gerning, Nicholas; Ludman, Peter; deBelder, Mark; Anderson, Richard; Mamas, Mamas A

    2016-08-01

    As coronary perforation (CP) is a rare but serious complication of percutaneous coronary intervention (PCI) the current evidence base is limited to small series. Using a national PCI database, the incidence, predictors, and outcomes of CP as a complication of PCI were defined. Data were prospectively collected and retrospectively analyzed from the British Cardiovascular Intervention Society data set on all PCI procedures performed in England and Wales between 2006 and 2013. Multivariate logistic regressions and propensity scores were used to identify predictors of CP and its association with outcomes. In total, 1762 CPs were recorded from 527 121 PCI procedures (incidence of 0.33%). Patients with CP were more often women or older, with a greater burden of comorbidity and underwent more complex PCI procedures. Factors predictive of CP included age per year (odds ratio [OR], 1.03; 95% confidence intervals, 1.02-1.03; P<0.001), previous coronary artery bypass graft (OR, 1.44; 95% confidence intervals, 1.17-1.77; P<0.001), left main (OR, 1.54; 95% confidence intervals, 1.21-1.96; P<0.001), use of rotational atherectomy (OR, 2.37; 95% confidence intervals, 1.80-3.11; P<0.001), and chronic total occlusions intervention (OR, 3.96; 95% confidence intervals, 3.28-4.78; P<0.001). Adjusted odds of adverse outcomes were higher in patients with CP for all major adverse coronary events, including stroke, bleeding, and mortality. Emergency surgery was required in 3% of cases. Predictors of mortality in patients with CP included age, diabetes mellitus, previous myocardial infarction, renal disease, ventilatory support, use of circulatory support, glycoprotein inhibitor use, and stent type. Using a national PCI database for the first time, the incidence, predictors, and outcomes of CP were defined. Although CP as a complication of PCI occurred rarely, it was strongly associated with poor outcomes. © 2016 American Heart Association, Inc.

  10. Mice Lacking the Circadian Modulators SHARP1 and SHARP2 Display Altered Sleep and Mixed State Endophenotypes of Psychiatric Disorders

    PubMed Central

    Shahmoradi, Ali; Reinecke, Lisa; Kroos, Christina; Wichert, Sven P.; Oster, Henrik; Wehr, Michael C.; Taneja, Reshma; Hirrlinger, Johannes; Rossner, Moritz J.

    2014-01-01

    Increasing evidence suggests that clock genes may be implicated in a spectrum of psychiatric diseases, including sleep and mood related disorders as well as schizophrenia. The bHLH transcription factors SHARP1/DEC2/BHLHE41 and SHARP2/DEC1/BHLHE40 are modulators of the circadian system and SHARP1/DEC2/BHLHE40 has been shown to regulate homeostatic sleep drive in humans. In this study, we characterized Sharp1 and Sharp2 double mutant mice (S1/2-/-) using online EEG recordings in living animals, behavioral assays and global gene expression profiling. EEG recordings revealed attenuated sleep/wake amplitudes and alterations of theta oscillations. Increased sleep in the dark phase is paralleled by reduced voluntary activity and cortical gene expression signatures reveal associations with psychiatric diseases. S1/2-/- mice display alterations in novelty induced activity, anxiety and curiosity. Moreover, mutant mice exhibit impaired working memory and deficits in prepulse inhibition resembling symptoms of psychiatric diseases. Network modeling indicates a connection between neural plasticity and clock genes, particularly for SHARP1 and PER1. Our findings support the hypothesis that abnormal sleep and certain (endo)phenotypes of psychiatric diseases may be caused by common mechanisms involving components of the molecular clock including SHARP1 and SHARP2. PMID:25340473

  11. Enhancements to the SHARP Build System and NEK5000 Coupling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCaskey, Alex; Bennett, Andrew R.; Billings, Jay Jay

    The SHARP project for the Department of Energy's Nuclear Energy Advanced Modeling and Simulation (NEAMS) program provides a multiphysics framework for coupled simulations of advanced nuclear reactor designs. It provides an overall coupling environment that utilizes custom interfaces to couple existing physics codes through a common spatial decomposition and unique solution transfer component. As of this writing, SHARP couples neutronics, thermal hydraulics, and structural mechanics using PROTEUS, Nek5000, and Diablo respectively. This report details two primary SHARP improvements regarding the Nek5000 and Diablo individual physics codes: (1) an improved Nek5000 coupling interface that lets SHARP achieve a vast increase inmore » overall solution accuracy by manipulating the structure of the internal Nek5000 spatial mesh, and (2) the capability to seamlessly couple structural mechanics calculations into the framework through improvements to the SHARP build system. The Nek5000 coupling interface now uses a barycentric Lagrange interpolation method that takes the vertex-based power and density computed from the PROTEUS neutronics solver and maps it to the user-specified, general-order Nek5000 spectral element mesh. Before this work, SHARP handled this vertex-based solution transfer in an averaging-based manner. SHARP users can now achieve higher levels of accuracy by specifying any arbitrary Nek5000 spectral mesh order. This improvement takes the average percentage error between the PROTEUS power solution and the Nek5000 interpolated result down drastically from over 23 % to just above 2 %, and maintains the correct power profile. We have integrated Diablo into the SHARP build system to facilitate the future coupling of structural mechanics calculations into SHARP. Previously, simulations involving Diablo were done in an iterative manner, requiring a large amount manual work, and left only as a task for advanced users. This report will detail a new Diablo build system that was implemented using GNU Autotools, mirroring much of the current SHARP build system, and easing the use of structural mechanics calculations for end-users of the SHARP multiphysics framework. It lets users easily build and use Diablo as a stand-alone simulation, as well as fully couple with the other SHARP physics modules. The top-level SHARP build system was modified to allow Diablo to hook in directly. New dependency handlers were implemented to let SHARP users easily build the framework with these new simulation capabilities. The remainder of this report will describe this work in full, with a detailed discussion of the overall design philosophy of SHARP, the new solution interpolation method introduced, and the Diablo integration work. We will conclude with a discussion of possible future SHARP improvements that will serve to increase solution accuracy and framework capability.« less

  12. [Perceptual sharpness metric for visible and infrared color fusion images].

    PubMed

    Gao, Shao-Shu; Jin, Wei-Qi; Wang, Xia; Wang, Ling-Xue; Luo, Yuan

    2012-12-01

    For visible and infrared color fusion images, objective sharpness assessment model is proposed to measure the clarity of detail and edge definition of the fusion image. Firstly, the contrast sensitivity functions (CSF) of the human visual system is used to reduce insensitive frequency components under certain viewing conditions. Secondly, perceptual contrast model, which takes human luminance masking effect into account, is proposed based on local band-limited contrast model. Finally, the perceptual contrast is calculated in the region of interest (contains image details and edges) in the fusion image to evaluate image perceptual sharpness. Experimental results show that the proposed perceptual sharpness metrics provides better predictions, which are more closely matched to human perceptual evaluations, than five existing sharpness (blur) metrics for color images. The proposed perceptual sharpness metrics can evaluate the perceptual sharpness for color fusion images effectively.

  13. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, HVLP COATING EQUIPMENT, SHARPE MANUFACTURING COMPANY PLATINUM 2012 HVLP SPRAY GUN

    EPA Science Inventory

    This report presents the results of the verification test of the Sharpe Platinum 2013 high-volume, low-pressure gravity-feed spray gun, hereafter referred to as the Sharpe Platinum, which is designed for use in automotive refinishing. The test coating chosen by Sharpe Manufacturi...

  14. 77 FR 52061 - Notice of Proposed Exemption Involving Sharp HealthCare Located in San Diego, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-28

    ...This document contains a notice of pendency (the Notice) before the Department of Labor (the Department) of a proposed individual exemption from certain prohibited transaction restrictions of the Employee Retirement Income Security Act of 1974 (the Act or ERISA). The transactions involve the Sharp HealthCare Health and Dental Plan (the Plan). The proposed exemption, if granted, would affect the Plan, its participants and beneficiaries, Sharp Healthcare (Sharp), and the Sharp Health Plan (the HMO).

  15. Implementing AORN recommended practices for sharps safety.

    PubMed

    Ford, Donna A

    2014-01-01

    Prevention of percutaneous sharps injuries in perioperative settings remains a challenge. Occupational transmission of bloodborne pathogens, not only from patients to health care providers but also from health care providers to patients, is a significant concern. Legislation and position statements geared toward ensuring the safety of patients and health care workers have not resulted in significantly reduced sharps injuries in perioperative settings. Awareness and understanding of the types of percutaneous injuries that occur in perioperative settings is fundamental to developing an effective sharps injury prevention program. The AORN "Recommended practices for sharps safety" clearly delineates evidence-based recommendations for sharps injury prevention. Perioperative RNs can lead efforts to change practice for the safety of patients and perioperative team members by promoting the elimination of sharps hazards; the use of engineering, work practice, and administrative controls; and the proper use of personal protective equipment, including double gloving. Copyright © 2014 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  16. The SHARP Program: Giving Kids Chances to Excel

    ERIC Educational Resources Information Center

    Kenney, Rich

    2007-01-01

    In this article, the author describes the Sports, Habilitation, and Recreation Program (SHARP), a program of the Foundation for Blind Children in Phoenix, Arizona. The SHARP program aims to help children, who have visual impairments, achieve goals, develop independence, and make friends. One of the unique features of the SHARP program is that it…

  17. Quantifying Arabia-Eurasia convergence accommodated in the Greater Caucasus by paleomagnetic reconstruction

    NASA Astrophysics Data System (ADS)

    van der Boon, A.; van Hinsbergen, D. J. J.; Rezaeian, M.; Gürer, D.; Honarmand, M.; Pastor-Galán, D.; Krijgsman, W.; Langereis, C. G.

    2018-01-01

    Since the late Eocene, convergence and subsequent collision between Arabia and Eurasia was accommodated both in the overriding Eurasian plate forming the Greater Caucasus orogen and the Iranian plateau, and by subduction and accretion of the Neotethys and Arabian margin forming the East Anatolian plateau and the Zagros. To quantify how much Arabia-Eurasia convergence was accommodated in the Greater Caucasus region, we here provide new paleomagnetic results from 97 volcanic sites (∼500 samples) in the Talysh Mountains of NW Iran, that show ∼15° net clockwise rotation relative to Eurasia since the Eocene. We apply a first-order kinematic restoration of the northward convex orocline that formed to the south of the Greater Caucasus, integrating our new data with previously published constraints on rotations of the Eastern Pontides and Lesser Caucasus. This suggests that north of the Talysh ∼120 km of convergence must have been accommodated. North of the Eastern Pontides and Lesser Caucasus this is significantly more: 200-280 km. Our reconstruction independently confirms previous Caucasus convergence estimates. Moreover, we show for the first time a sharp contrast of convergence between the Lesser Caucasus and the Talysh. This implies that the ancient Paleozoic-Mesozoic transform plate boundary, preserved between the Iranian and East-Anatolian plateaus, was likely reactivated as a right-lateral transform fault since late Eocene time.

  18. Dixon water-fat separation in PROPELLER MRI acquired with two interleaved echoes.

    PubMed

    Schär, Michael; Eggers, Holger; Zwart, Nicholas R; Chang, Yuchou; Bakhru, Akshay; Pipe, James G

    2016-02-01

    To propose a novel combination of robust Dixon fat suppression and motion insensitive PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) MRI. Two different echoes were acquired interleaved in each shot enabling water-fat separation on individual blades. Fat, which was blurred in standard PROPELLER because the water-fat shift (WFS) rotated with the blades, was shifted back in each blade. Additionally, field maps obtained from the water-fat separation were used to unwarp off-resonance-induced shifts in each blade. PROPELLER was then applied to the water, corrected fat, or recombined water-fat blades. This approach was compared quantitatively in volunteers with regard to motion estimation and signal-to-noise ratio (SNR) to a standard PROPELLER acquisition with minimal WFS and fat suppression. Shifting the fat back in each blade reduced errors in the translation correction. SNR in the proposed Dixon PROPELLER was 21% higher compared with standard PROPELLER with identical scan time. High image quality was achieved even when the volunteers were moving during data acquisition. Furthermore, sharp water-fat borders and image details were seen in areas where standard PROPELLER suffered from blurring when acquired with a low readout bandwidth. The proposed method enables motion-insensitive PROPELLER MRI with robust fat suppression and reduced blurring. Additionally, fat images are available if desired. © 2015 Wiley Periodicals, Inc.

  19. Contact sheet recording with a self-acting negative air bearing

    NASA Technical Reports Server (NTRS)

    Muftu , Sinan (Inventor); Hinteregger, Hans F (Inventor)

    2000-01-01

    A flat head and a tape transport arrangement impart a wrap angle to the tape at the upstream corner of the head. The wrap angle, corner sharpness and tape stiffness are sufficient to cause a moving tape to form a hollow bump at the upstream corner, thereby creating a hollow into which entrained air can expand, causing a subambient pressure within and downstream of the bump. This pressure keeps the tape in contact with the head. It is created without the need for a groove or complex pressure relief slot(s). No contact pressure arises at the signal exchange site due to media wrap. The highest contact pressures are developed at a wrapped upstream corner. For a tape drive, traveling in both forward and reverse, the wrap can be at both the upstream and downstream (which is the reverse upstream) corners. Heads that are not flat can also be used, if the wrap angle relative to a main surface is sufficient and not too large. The wrapped head can also be used with rotating media, such as disks (floppy and hard) and rotating heads, such as helical wound heads for video recording. Multiple flat tape bearing surfaces can be separated by grooves and/or angles. Each flat can carry heads along one or more gap lines. Multiple adjacent narrow tracks can thus be written for extreme high track density recording.

  20. Synthesis and characterization of carboxymethyl potato starch and its application in reactive dye printing.

    PubMed

    Zhang, Bing; Gong, Honghong; Lü, Shaoyu; Ni, Boli; Liu, Mingzhu; Gao, Chunmei; Huang, Yinjuan; Han, Fei

    2012-11-01

    Carboxymethyl potato starch (CMPS) was synthesized with a simple dry and multi-step method as a product of the reaction of native potato starch and monochloroacetic acid in the presence of sodium hydroxide. The influence of the molar ratio of sodium hydroxide to anhydroglucose unit, the volume of 95% (v/v) ethanol, the rotation rate of motor driven stirrer and the reaction time for degree of substitution (DS) were evaluated. The product was characterized by Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and X-ray diffractometry (XRD). FTIR spectrometry showed new bonds at 1618 and 1424 cm⁻¹ when native starch underwent carboxymethylation. SEM pictures showed that the smooth surface of native starch particles was mostly ruptured. XRD revealed that starch crystallinity was reduced after carboxymethylation. The viscosity of the mixture paste of carboxymethyl starch and sodium alginate (SA) was measured using a rotational viscometer. In addition, the applied effect of mixed paste in reactive dye printing was examined by assessing the fabric stiffness, color yield and sharp edge to the printed image in comparison with SA. And the results indicated that the mixed paste could partially replace SA as thickener in reactive dye printing. The study also showed that the method was low cost and eco-friendly and the product would have an extensive application in reactive dye printing. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Vibrational Population Distribution in Formaldehyde Expanding from Chen Pyrolysis Nozzle Measured by Chirped Pulse Millimeter Wave Spectroscopy

    NASA Astrophysics Data System (ADS)

    Kuyanov-Prozument, Kirill; Vasiliou, Angayle; Park, G. Barratt; Muenter, John S.; Stanton, John F.; Ellison, G. Barney; Field, Robert W.

    2011-06-01

    Knowing the vibrational population distribution of unimolecular fragmentation reaction products can reveal the reaction mechanism. Here, we applied Chirped Pulse Millimeter Wave (CPmmW) spectroscopy, invented by Brooks Pate and co-workers, to detect the vibrational population distribution of formaldehyde produced by pyrolysis of methyl nitrite (CH_3ONO) or ethyl nitrite (CH_3CH_2ONO). The pure rotational spectrum contains information about vibrational populations via the known vibration dependence of the rotational constants, which is easily observed in the millimeter-wave spectrum. Only two of six vibrational modes of formaldehyde are significantly populated in both pyrolysis decomposition reactions and in an expansion of pure formaldehyde, suggesting that it is the collisional energy transfer that primarily determines the vibrational population distribution. The non-Boltzmann population distribution among the observed vibrational modes demonstrates non-statistical vibrational energy transfer in formaldehyde. It is in sharp contrast with the equilibrated population distribution measured in OCS and the almost complete vibrational relaxation observed in acetaldehyde. This work is supported by grants from the US Department of Energy and the ACS Petroleum Research Fund, and the National Science Foundation grant "Organic Radicals in Biomass Decomposition: Mechanisms & Dynamics," (CHE-0848606) G. G. Brown, B. C. Dian, K. O. Douglass, S. M. Geyer, S. T. Shipman and B. H. Pate Rev. Sci. Instrum. 79, 053103 (1995).

  2. Insulin stimulates the expression of the SHARP-1 gene via multiple signaling pathways.

    PubMed

    Takagi, K; Asano, K; Haneishi, A; Ono, M; Komatsu, Y; Yamamoto, T; Tanaka, T; Ueno, H; Ogawa, W; Tomita, K; Noguchi, T; Yamada, K

    2014-06-01

    The rat enhancer of split- and hairy-related protein-1 (SHARP-1) is a basic helix-loop-helix transcription factor. An issue of whether SHARP-1 is an insulin-inducible transcription factor was examined. Insulin rapidly increased the level of SHARP-1 mRNA both in vivo and in vitro. Then, signaling pathways involved with the increase of SHARP-1 mRNA by insulin were determined in H4IIE rat hepatoma cells. Pretreatments with LY294002, wortmannin, and staurosporine completely blocked the induction effect, suggesting the involvement of both phosphoinositide 3-kinase (PI 3-K) and protein kinase C (PKC) pathways. In fact, overexpression of a dominant negative form of atypical protein kinase C lambda (aPKCλ) significantly decreased the induction of the SHARP-1 mRNA. In addition, inhibitors for the small GTPase Rac or Jun N-terminal kinase (JNK) also blocked the induction of SHARP-1 mRNA by insulin. Overexpression of a dominant negative form of Rac1 prevented the activation by insulin. Furthermore, actinomycin D and cycloheximide completely blocked the induction of SHARP-1 mRNA by insulin. Finally, when a SHARP-1 expression plasmid was transiently transfected with various reporter plasmids into H4IIE cells, the promoter activity of PEPCK reporter plasmid was specifically decreased. Thus, we conclude that insulin induces the SHARP-1 gene expression at the transcription level via a both PI 3-K/aPKCλ/JNK- and a PI 3-K/Rac/JNK-signaling pathway; protein synthesis is required for this induction; and that SHARP-1 is a potential repressor of the PEPCK gene expression. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Background field removal technique using regularization enabled sophisticated harmonic artifact reduction for phase data with varying kernel sizes.

    PubMed

    Kan, Hirohito; Kasai, Harumasa; Arai, Nobuyuki; Kunitomo, Hiroshi; Hirose, Yasujiro; Shibamoto, Yuta

    2016-09-01

    An effective background field removal technique is desired for more accurate quantitative susceptibility mapping (QSM) prior to dipole inversion. The aim of this study was to evaluate the accuracy of regularization enabled sophisticated harmonic artifact reduction for phase data with varying spherical kernel sizes (REV-SHARP) method using a three-dimensional head phantom and human brain data. The proposed REV-SHARP method used the spherical mean value operation and Tikhonov regularization in the deconvolution process, with varying 2-14mm kernel sizes. The kernel sizes were gradually reduced, similar to the SHARP with varying spherical kernel (VSHARP) method. We determined the relative errors and relationships between the true local field and estimated local field in REV-SHARP, VSHARP, projection onto dipole fields (PDF), and regularization enabled SHARP (RESHARP). Human experiment was also conducted using REV-SHARP, VSHARP, PDF, and RESHARP. The relative errors in the numerical phantom study were 0.386, 0.448, 0.838, and 0.452 for REV-SHARP, VSHARP, PDF, and RESHARP. REV-SHARP result exhibited the highest correlation between the true local field and estimated local field. The linear regression slopes were 1.005, 1.124, 0.988, and 0.536 for REV-SHARP, VSHARP, PDF, and RESHARP in regions of interest on the three-dimensional head phantom. In human experiments, no obvious errors due to artifacts were present in REV-SHARP. The proposed REV-SHARP is a new method combined with variable spherical kernel size and Tikhonov regularization. This technique might make it possible to be more accurate backgroud field removal and help to achive better accuracy of QSM. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Summer High School Apprenticeship Research Program (SHARP)

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The summer of 1997 will not only be noted by NASA for the mission to Mars by the Pathfinder but also for the 179 brilliant apprentices that participated in the SHARP Program. Apprentice participation increased 17% over last year's total of 153 participants. As indicated by the End-of-the-Program Evaluations, 96% of the programs' participants rated the summer experience from very good to excellent. The SHARP Management Team began the year by meeting in Cocoa Beach, Florida for the annual SHARP Planning Conference. Participants strengthened their Education Division Computer Aided Tracking System (EDCATS) skills, toured the world-renowned Kennedy Space Center, and took a journey into space during the Alien Encounter Exercise. The participants returned to their Centers with the same goals and objectives in mind. The 1997 SHARP Program goals were: (1) Utilize NASA's mission, unique facilities and specialized workforce to provide exposure, education, and enrichment experiences to expand participants' career horizons and inspire excellence in formal education and lifelong learning. (2) Develop and implement innovative education reform initiatives which support NASA's Education Strategic Plan and national education goals. (3) Utilize established statistical indicators to measure the effectiveness of SHARP's program goals. (4) Explore new recruiting methods which target the student population for which SHARP was specifically designed. (5) Increase the number of participants in the program. All of the SHARP Coordinators reported that the goals and objectives for the overall program as well as their individual program goals were achieved. Some of the goals and objectives for the Centers were: (1) To increase the students' awareness of science, mathematics, engineering, and computer technology; (2) To provide students with the opportunity to broaden their career objectives; and (3) To expose students to a variety of enrichment activities. Most of the Center goals and objectives were consistent with the overall program goals. Modem Technology Systems, Inc., was able to meet the SHARP Apprentices, Coordinators and Mentors during their site visits to Stennis Space Center, Ames Research Center and Dryden Flight Research Center. All three Centers had very efficient programs and adhered to SHARP's general guidelines and procedures. MTSI was able to meet the apprentices from the other Centers via satellite in July during the SHARP Video-Teleconference(ViTS). The ViTS offered the apprentices and the NASA and SHARP Coordinators the opportunity to introduce themselves. The apprentices from each Center presented topical "Cutting Edge Projects". Some of the accomplishments for the 1997 SHARP Program year included: MTSI hiring apprentices from four of the nine NASA Centers, the full utilization of the EDCATS by apprentices and NASA/SHARP Coordinators, the distribution of the SHARP Apprentice College and Scholarship Directory, a reunion with former apprentices from Langley Research Center and the development of a SHARP Recruitment Poster. MTSI developed another exciting newsletter containing graphics and articles submitted by the apprentices and the SHARP Management Team.

  5. Titan's Atmospheric Dynamics and Meteorology

    NASA Technical Reports Server (NTRS)

    Flasar, F. M.; Baines, K. H.; Bird, M. K.; Tokano, T.; West, R. A.

    2008-01-01

    Titan, after Venus, is the second example of an atmosphere with a global cyclostrophic circulation in the solar system, but a circulation that has a strong seasonal modulation in the middle atmosphere. Direct measurement of Titan's winds, particularly observations tracking the Huygens probe at 10degS, indicate that the zonal winds are generally in the sense of the satellites rotation. They become cyclostrophic approx. 35 km above the surface and generally increase with altitude, with the exception of a sharp minimum centered near 75 km, where the wind velocity decreases to nearly zero. Zonal winds derived from the temperature field retrieved from Cassini measurements, using the thermal wind equation, indicate a strong winter circumpolar vortex, with maximum winds at mid northern latitudes of 190 ms-' near 300 km. Above this level, the vortex decays. Curiously, the zonal winds and temperatures are symmetric about a pole that is offset from the surface pole by approx.4 degrees. The cause of this is not well understood, but it may reflect the response of a cyclostrophic circulation to the offset between the equator, where the distance to the rotation axis is greatest, and the solar equator. The mean meridional circulation can be inferred from the temperature field and the meridional distribution of organic molecules and condensates and hazes. Both the warm temperatures in the north polar region near 400 km and the enhanced concentration of several organic molecules suggests subsidence there during winter and early spring. Stratospheric condensates are localized at high northern latitudes, with a sharp cut-off near 50degN. Titan's winter polar vortex appears to share many of the same characteristics of winter vortices on Earth-the ozone holes. Global mapping of temperatures, winds, and composition in he troposphere, by contrast, is incomplete. The few suitable discrete clouds that have bee found for tracking indicate smaller velocities than aloft, consistent with the Huygens measurements. At low latitudes the zonal winds near the surface appear not to be westward as on Earth, but eastward. Because the net zonal-mean time-averaged torq exerted by the surface on the atmosphere should vanish, this implies westward flow o part of the surface; the question is where. The latitude contrast in tropospheric temperatures, deduced from radio occultations at low, mid, and high latitudes, is small approx.5 K at the tropopause and approx.3 K at the surface.

  6. SHARP: Spacecraft Health Automated Reasoning Prototype

    NASA Technical Reports Server (NTRS)

    Atkinson, David J.

    1991-01-01

    The planetary spacecraft mission OPS as applied to SHARP is studied. Knowledge systems involved in this study are detailed. SHARP development task and Voyager telecom link analysis were examined. It was concluded that artificial intelligence has a proven capability to deliver useful functions in a real time space flight operations environment. SHARP has precipitated major change in acceptance of automation at JPL. The potential payoff from automation using AI is substantial. SHARP, and other AI technology is being transferred into systems in development including mission operations automation, science data systems, and infrastructure applications.

  7. The Formation of Magnetic Depletions and Flux Annihilation Due to Reconnection in the Heliosheath

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Drake, J. F.; Swisdak, M.; Opher, M.

    The misalignment of the solar rotation axis and the magnetic axis of the Sun produces a periodic reversal of the Parker spiral magnetic field and the sectored solar wind. The compression of the sectors is expected to lead to reconnection in the heliosheath (HS). We present particle-in-cell simulations of the sectored HS that reflect the plasma environment along the Voyager 1 and 2 trajectories, specifically including unequal positive and negative azimuthal magnetic flux as seen in the Voyager data. Reconnection proceeds on individual current sheets until islands on adjacent current layers merge. At late time, bands of the dominant fluxmore » survive, separated by bands of deep magnetic field depletion. The ambient plasma pressure supports the strong magnetic pressure variation so that pressure is anticorrelated with magnetic field strength. There is little variation in the magnetic field direction across the boundaries of the magnetic depressions. At irregular intervals within the magnetic depressions are long-lived pairs of magnetic islands where the magnetic field direction reverses so that spacecraft data would reveal sharp magnetic field depressions with only occasional crossings with jumps in magnetic field direction. This is typical of the magnetic field data from the Voyager spacecraft. Voyager 2 data reveal that fluctuations in the density and magnetic field strength are anticorrelated in the sector zone, as expected from reconnection, but not in unipolar regions. The consequence of the annihilation of subdominant flux is a sharp reduction in the number of sectors and a loss in magnetic flux, as documented from the Voyager 1 magnetic field and flow data.« less

  8. Curiosity Self-Portrait at Martian Sand Dune

    NASA Image and Video Library

    2016-01-29

    This self-portrait of NASA's Curiosity Mars rover shows the vehicle at "Namib Dune," where the rover's activities included scuffing into the dune with a wheel and scooping samples of sand for laboratory analysis. The scene combines 57 images taken on Jan. 19, 2016, during the 1,228th Martian day, or sol, of Curiosity's work on Mars. The camera used for this is the Mars Hand Lens Imager (MAHLI) at the end of the rover's robotic arm. Namib Dune is part of the dark-sand "Bagnold Dune Field" along the northwestern flank of Mount Sharp. Images taken from orbit have shown that dunes in the Bagnold field move as much as about 3 feet (1 meter) per Earth year. The location of Namib Dune is show on a map of Curiosity's route at http://mars.nasa.gov/msl/multimedia/images/?ImageID=7640. The relationship of Bagnold Dune Field to the lower portion of Mount Sharp is shown in a map at PIA16064. The view does not include the rover's arm. Wrist motions and turret rotations on the arm allowed MAHLI to acquire the mosaic's component images. The arm was positioned out of the shot in the images, or portions of images, that were used in this mosaic. This process was used previously in acquiring and assembling Curiosity self-portraits taken at sample-collection sites, including "Rocknest" (PIA16468), "Windjana" (PIA18390) and "Buckskin" (PIA19807). For scale, the rover's wheels are 20 inches (50 centimeters) in diameter and about 16 inches (40 centimeters) wide. Other Curiosity self-portraits are available at http://photojournal.jpl.nasa.gov/catalog/PIA20316

  9. Behavior of healthcare workers after injuries from sharp instruments.

    PubMed

    Adib-Hajbaghery, Mohsen; Lotfi, Mohammad Sajjad

    2013-09-01

    Injuries with sharps are common occupational hazards for healthcare workers. Such injuries predispose the staff to dangerous infections such as hepatitis B, C and HIV. The present study was conducted to investigate the behaviors of healthcare workers in Kashan healthcare centers after needle sticks and injuries with sharps in 2012. A cross-sectional study was conducted on 298 healthcare workers of medical centers governed by Kashan University of Medical Sciences. A questionnaire was used in this study. The first part included questions about demographic characteristics. The second part of the questionnaire consisted of 16 items related to the sharp instrument injuries. For data analysis, descriptive and analytical statistics (chi-square, ANOVA and Pearson correlation coefficient) SPSS version 16.0 software was used. From a total of 298 healthcare workers, 114 (38.3%) had a history of injury from needles and sharp instruments in the last six months. Most needle stick and sharp instrument injuries had occurred among the operating room nurses and midwifes; 32.5% of injuries from sharp instruments occurred in the morning shift. Needles were responsible for 46.5% of injuries. The most common actions taken after needle stick injuries were compression (27.2%) and washing the area with soap and water (15.8%). Only 44.6% of the injured personnel pursued follow-up measures after a needle stick or sharp instrument injury. More than a half of the healthcare workers with needle stick or sharp instrument injury had refused follow-up for various reasons. The authorities should implement education programs along with protocols to be implemented after needle stick injuries or sharps.

  10. The impact of sharps injuries on student nurses: a systematic review.

    PubMed

    Hambridge, Kevin; Nichols, Andrew; Endacott, Ruth

    2016-10-27

    The purpose of this review was to discover the impact of sharps injuries in the student nurse population. Much is known and reported about sharps injuries in registered nurses, but there has been a lack of published evidence regarding sharps injuries within the student nurse population. A systematic review of nursing, health and psychology databases was conducted. The limits set were publications between 1980 and 2014 in the English language. Studies were identified then, following a rigorous critical and quality appraisal with validated tools, were selected for the systematic review. A total of 40 articles met the inclusion criteria, reporting studies conducted in 18 countries. Psychological and physical impacts of sharps injuries in student nurses were reported, such as fear, anxiety and depression, although these impacts were not quantified using a validated instrument. The impact of sharps injuries can be severe, both psychological and physical. This systematic review shows that further research is needed into this, especially in under-researched areas such as the UK, to establish the impact of sharps injuries within this population. Further research would also aid the education and prevention of this harmful problem. The review also emphasises the psychological issues relating to sharps injuries, the impact these can have on individuals and the support and counselling that student nurses require after injury. These findings highlight the potential psychological issues that can result from sharps injuries in this population.

  11. An acoustofluidic micromixer based on oscillating sidewall sharp-edges.

    PubMed

    Huang, Po-Hsun; Xie, Yuliang; Ahmed, Daniel; Rufo, Joseph; Nama, Nitesh; Chen, Yuchao; Chan, Chung Yu; Huang, Tony Jun

    2013-10-07

    Rapid and homogeneous mixing inside a microfluidic channel is demonstrated via the acoustic streaming phenomenon induced by the oscillation of sidewall sharp-edges. By optimizing the design of the sharp-edges, excellent mixing performance and fast mixing speed can be achieved in a simple device, making our sharp-edge-based acoustic micromixer a promising candidate for a wide variety of applications.

  12. Composite, ordered material having sharp surface features

    DOEpatents

    D'Urso, Brian R.; Simpson, John T.

    2006-12-19

    A composite material having sharp surface features includes a recessive phase and a protrusive phase, the recessive phase having a higher susceptibility to a preselected etchant than the protrusive phase, the composite material having an etched surface wherein the protrusive phase protrudes from the surface to form a sharp surface feature. The sharp surface features can be coated to make the surface super-hydrophobic.

  13. Hindered rotations probed by rare earths in crystals: Er3+ and Tm3+ in BaY2F8

    NASA Astrophysics Data System (ADS)

    Baraldi, A.; Buffagni, E.; Capelletti, R.; Mazzera, M.; Magnani, N.; Carini, G., Jr.; D'Angelo, G.

    2009-10-01

    The sharpness of absorption lines induced by crystal-field (CF) transitions of rare earths (RE) can be exploited to disclose the rotational structure usually hidden under the more common broad electronic absorptions. In the present work the effectiveness of such an approach is proved by the analysis of the fine structure (FS) accompanying the Er3+ and Tm3+ CF lines in BaY2F8 single crystals. Sequences of weak, very narrow (0.03-0.1cm-1) , closely spaced (˜0.2-0.8cm-1) lines were monitored in high-resolution (as fine as 0.01cm-1 ), low-temperature (9 K) absorption spectra in the 2000-24000cm-1 range. The FS covers a few cm-1 on both sides of the narrowest among the RE-CF lines and is tightly associated with them, as proved by the amplitude dependence on the RE concentration (in the 0.5-20at.% range) and by linear dichroism measurements. The FS lines vanishing at temperatures as low as 40-60 K and the close spacing suggest that they may be ascribed to the simultaneous excitation of both RE-CF electronic transition and hindered rotation (or libration) mode of RE3+-F- group. The attribution is supported both by the specific structure of the host matrix which allows some F- mobility and by the very small line spacing which is in excellent agreement with the RE3+-F- rotational constant (2B=0.39cm-1) . Complementary specific-heat measurements in the temperature range 1.5-25 K show that Er3+ -doped samples display contributions, in addition to the vibrational one of a pure sample, which scale with the Er3+ concentration. The extra specific heat is interpreted in terms of Schottky anomalies; that peaking at ˜17K accounts for electronic transitions between the lowest sublevels of the I415/2 ground manifold, in agreement with the CF spectroscopy results while those occurring below 3.5 K are consistent with level pairs separated by 0.55 and 0.36cm-1 , in agreement with the FS line spacing.

  14. Paleomagnetic reconstruction of the Neotethyan Suture in Central Anatolia (Turkey)

    NASA Astrophysics Data System (ADS)

    Ozkaptan, M.; Gulyuz, E.; Kaymakci, N.; Langereis, C. G.

    2016-12-01

    The consumption of the Neo-Tethyan Ocean and the accretion of intervening continental blocks such as the Taurides and Kırşehir Block in the south and the Pontides in the north since the Mesozoic occurred along two sutures. The İzmir-Ankara Suture Zone (IASZ) between the Pontides in the north and the Taurides in the south and Intra-Tauride suture Zone (ITSZ) between the Taurides and the Kırşehir block meets around the Haymana Basin. The IASZ follows roughly an E-W trend and makes a sharp bend of approximately of 90° along the western margin of the Çankırı Basin. The ITSZ, on the other hand, follows a NW-SE trend parallel to the Tuz Gölü Fault Zone and overprinted by the structures related to the İASZ in the north. From West to East; the Haymana, Tuz Gölü and Çankırı basins straddle these suture zones and are developed in relation to the subduction and collision processes, which make them invaluable for unraveling deformation history and evolution of the Neotethys. In this regard we have conducted a very detailed paleomagnetic study to determine vertical axis rotations in the region, mainly on the Late Cretaceous to Recent infill of these basins. Results have shown that the region undergone strong clockwise (CW) and counter-clockwise (CCW) rotations, up to ±90° in places, resulting in the present geometry of the region. The central part of the Haymana Basin rotated as much as 90° CCW sense while its northern parts and the Tuz Gölü basin rotated 30° CW sense, which contradicts with almost all the published paleomagnetic results from the region. The restored geometries, based on new paleomagnetic data indicate that Haymana, Tuz Gölü basins and the SW margin of the Çankırı Basin were initially oriented in N-S direction prior to the Eocene. These results indicate that the most of the paleogeographical maps and evolutionary scenarios and models proposed for the region previously requires major re-thinking and serious revisions.

  15. Fourier Transform Microwave Spectrum of CO{_2} -(CH{_3}){_2} S

    NASA Astrophysics Data System (ADS)

    Kawashima, Yoshiyuki; Moritani, Takayuki; Hirota, Eizi

    2012-06-01

    In spite of the fact that the oxygen and sulfur atoms belong to the same group in the periodic table, oxygen-containing molecules and their corresponding sulfur analogues often exhibit characteristic differences in their chemical and physical properties. We have been interested in these differences and have investigated, in a systematic way using Fourier transform microwave (FTMW) spectroscopy combined with ab initio molecular orbital calculations, complexes consisting of dimethyl ether (DME)/dimethyl sulfide (DMS) and ethylene oxide (EO)/ ethylene sulfide (ES), each being attached to either one of rare gas atoms (Rg), CO, N{_2}, or CO{_2}. Among others the CO{_2}-DMS complex should be mentioned, which, in sharp contrast with its counterpart: CO{_2}-DME behaves anomalously, presumably because of low-frequency internal motions, and we have decided to explore it in detail by a FTMW spectrometer. We have generated the CO{_2}-DMS complex by supersonic expansion of a CO{_2} and DMS mixture diluted with Ar, and have scanned the frequency region from 5 to 24 GHz to record the rotational spectra of the complex. We have found it difficult to fit the observed transition frequencies to the ordinary rotational Hamiltonian, but have succeeded to assign 75 transitions by sum rules among the observed transition frequencies. We are suspecting the anomalous behavior of the complex to be caused by a low-frequency torsion of the moieties. In the case of the CO{_2}-DME, the internal rotations of the two methyl groups of the DME were shown to be locked to the CO{_2} by hydrogen bonding, whereas, for the CO{_2}-DMS, we have observed internal-rotation splittings of the two methyl groups of the DMS, indicating the structure of the CO{_2}-DMS complex being considerably different from that of the CO{_2}-DME. We will report the structure at the potential minima and the internal motion of the CO{_2}-DMS, in comparison with the results predicted by quantum chemical calculations. Y. Kawashima, A. Sato, Y. Orita, and E. Hirota J. Phys. Chem. A 116, 1224 2012. J. J. Newby, R. A. Peebles, and S. A. Peebles J. Phys. Chem. A 108, 11234 2004.

  16. An acoustofluidic micromixer based on oscillating sidewall sharp-edges†

    PubMed Central

    Huang, Po-Hsun; Xie, Yuliang; Ahmed, Daniel; Rufo, Joseph; Nama, Nitesh; Chen, Yuchao; Chan, Chung Yu; Huang, Tony Jun

    2014-01-01

    Rapid and homogeneous mixing inside a microfluidic channel is demonstrated via the acoustic streaming phenomenon induced by the oscillation of sidewall sharp-edges. By optimizing the design of the sharp-edges, excellent mixing performance and fast mixing speed can be achieved in a simple device, making our sharp-edge-based acoustic micromixer a promising candidate for a wide variety of applications. PMID:23896797

  17. SHARP User Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Y. Q.; Shemon, E. R.; Thomas, J. W.

    SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculationmore » with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.« less

  18. Microstructural and hardness investigations on a dissimilar metal weld between low alloy steel and Alloy 82 weld metal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Z.R., E-mail: raymix@aliyun.com

    The investigation on microstructure and hardness at the fusion boundary (FB) region of a dissimilar metal weld (DMW) between low alloy steel (LAS) A508-III and Alloy 82 weld metal (WM) was carried out. The results indicated that there were two kinds of FBs, martensite FB and sharp FB, with obvious different microstructures, alternately distributed in the same FB. The martensite FB region had a gradual change of elemental concentration across FB, columnar WM grains with high length/width ratios, a thick martensite layer and a wide heat affected zone (HAZ) with large prior austenite grains. By comparison, the sharp FB regionmore » had a relatively sharp change of elemental concentration across the FB, WM grains with low length/width ratios and a narrow HAZ with smaller prior austenite grains. The martensite possessed a K-S orientation relationship with WM grains, while no orientation relationship was found between the HAZ grains and WM grains at the sharp FB. Compared with sharp FB there were much more Σ3 boundaries in the HAZ beside martensite FB. The hardness maximum of the martensite FB was much higher than that of the sharp FB, which was attributed to the martensite layer at the martensite FB. - Highlights: •Martensite and sharp FBs with different microstructures were found in the same FB. •There were high length/width-ratio WM grains and a wide HAZ beside martensite FB. •There were low length/width-ratio WM grains and a narrow HAZ beside sharp FB. •Compared with sharp FB, there were much more Σ3 boundaries in HAZ of martensite FB. •Hardness maximium of martensite FB was much higher than that of sharp FB.« less

  19. Notes on breeding sharp-shinned hawks and cooper’s hawks in Barnwell County, South Carolina

    Treesearch

    Mark Vukovich; John C. Kilgo

    2009-01-01

    Breeding records of Accipiter striatus (Sharp-shinned Hawks) in the southeastern US are scattered and isolated. We documented a Sharp-shinned Hawk and Accipiter cooperii (Cooper’s Hawk) nest while conducting a telemetry study on Melanerpes erythrocephalus (Red-headed Woodpeckers) in Barnwell County, SC in 2006 and 2007. We report the first known nest of a Sharp-shinned...

  20. Edge Sharpness Assessment by Parametric Modeling: Application to Magnetic Resonance Imaging.

    PubMed

    Ahmad, R; Ding, Y; Simonetti, O P

    2015-05-01

    In biomedical imaging, edge sharpness is an important yet often overlooked image quality metric. In this work, a semi-automatic method to quantify edge sharpness in the presence of significant noise is presented with application to magnetic resonance imaging (MRI). The method is based on parametric modeling of image edges. First, an edge map is automatically generated and one or more edges-of-interest (EOI) are manually selected using graphical user interface. Multiple exclusion criteria are then enforced to eliminate edge pixels that are potentially not suitable for sharpness assessment. Second, at each pixel of the EOI, an image intensity profile is read along a small line segment that runs locally normal to the EOI. Third, the profiles corresponding to all EOI pixels are individually fitted with a sigmoid function characterized by four parameters, including one that represents edge sharpness. Last, the distribution of the sharpness parameter is used to quantify edge sharpness. For validation, the method is applied to simulated data as well as MRI data from both phantom imaging and cine imaging experiments. This method allows for fast, quantitative evaluation of edge sharpness even in images with poor signal-to-noise ratio. Although the utility of this method is demonstrated for MRI, it can be adapted for other medical imaging applications.

  1. S-HARP: A parallel dynamic spectral partitioner

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sohn, A.; Simon, H.

    1998-01-01

    Computational science problems with adaptive meshes involve dynamic load balancing when implemented on parallel machines. This dynamic load balancing requires fast partitioning of computational meshes at run time. The authors present in this report a fast parallel dynamic partitioner, called S-HARP. The underlying principles of S-HARP are the fast feature of inertial partitioning and the quality feature of spectral partitioning. S-HARP partitions a graph from scratch, requiring no partition information from previous iterations. Two types of parallelism have been exploited in S-HARP, fine grain loop level parallelism and coarse grain recursive parallelism. The parallel partitioner has been implemented in Messagemore » Passing Interface on Cray T3E and IBM SP2 for portability. Experimental results indicate that S-HARP can partition a mesh of over 100,000 vertices into 256 partitions in 0.2 seconds on a 64 processor Cray T3E. S-HARP is much more scalable than other dynamic partitioners, giving over 15 fold speedup on 64 processors while ParaMeTiS1.0 gives a few fold speedup. Experimental results demonstrate that S-HARP is three to 10 times faster than the dynamic partitioners ParaMeTiS and Jostle on six computational meshes of size over 100,000 vertices.« less

  2. Mid-infrared coronary laser angioplasty with multifiber catheters

    NASA Astrophysics Data System (ADS)

    White, Christopher J.; Ramee, Stephen R.; Collins, Tyrone J.

    1993-06-01

    Mid-infrared laser wavelengths offer advantages as a source for coronary angioplasty based upon the excellent fiberoptic transmission and the enhanced tissue absorption of these photons. We report the results of a pilot clinical trial of a Holmium:YAG (2.1 micrometers ) coronary laser angioplasty using a prototype (1.6 mm and 2.0 mm) multifiber catheters. Coronary laser angioplasty with or without adjunctive balloon angioplasty or directional atherectomy was performed in 14 patients with 17 coronary stenoses. Laser success was obtained in 13/14 (93%) patients and 16/17 (94%) lesions. Uncomplicated procedural success was achieved in 9/14 (64%) patients and 12/17 (71%) lesions. Our initial laser success rate was very encouraging using this prototype multifiber catheter with a holmium:YAG laser. However, our overall procedural success rate was disappointing, and not superior to that expected with conventional angioplasty alone. The holmium laser remains an attractive energy source for laser angioplasty, but its utility is limited by catheters which create inadequate channels for stand-alone laser angioplasty.

  3. Display Considerations For Intravascular Ultrasonic Imaging

    NASA Astrophysics Data System (ADS)

    Gessert, James M.; Krinke, Charlie; Mallery, John A.; Zalesky, Paul J.

    1989-08-01

    A display has been developed for intravascular ultrasonic imaging. Design of this display has a primary goal of providing guidance information for therapeutic interventions such as balloons, lasers, and atherectomy devices. Design considerations include catheter configuration, anatomy, acoustic properties of normal and diseased tissue, catheterization laboratory and operating room environment, acoustic and electrical safety, acoustic data sampling issues, and logistical support such as image measurement, storage and retrieval. Intravascular imaging is in an early stage of development so design flexibility and expandability are very important. The display which has been developed is capable of acquisition and display of grey scale images at rates varying from static B-scans to 30 frames per second. It stores images in a 640 X 480 X 8 bit format and is capable of black and white as well as color display in multiplevideo formats. The design is based on the industry standard PC-AT architecture and consists of two AT style circuit cards, one for high speed sampling and the other for scan conversion, graphics and video generation.

  4. Endovascular surgery for peripheral arterial occlusive disease. A critical review.

    PubMed Central

    Ahn, S S; Eton, D; Moore, W S

    1992-01-01

    Endovascular surgery is a new multidisciplinary field that applies the recently innovated techniques of angioscopy, intraluminal ultrasound, balloon angioplasty, laser, mechanical atherectomy, and stents. This field can be defined as a diagnostic and therapeutic discipline that uses catheter-based systems to treat vascular disease. As such, it integrates the subspecialties of vascular surgery, interventional radiology, interventional cardiology, and biomedical engineering for the common purpose of improving arterial hemodynamics. Endovascular surgery offers many potential benefits: long incisions are replaced with a puncture wound, the need for postoperative intensive care is significantly reduced, major cardiac and pulmonary complications from general anesthesia are side stepped, and the dollar savings could be dramatic as the need for intensive care unit and in-hospital stay diminishes. Despite these technological advancements, endovascular surgery is still in its infancy and currently has limited applications. This review provides an updated summary of endovascular surgery today and addresses some of the obstacles still preventing its widespread use. PMID:1385944

  5. Induction of the SHARP-2 mRNA level by insulin is mediated by multiple signaling pathways.

    PubMed

    Kanai, Yukiko; Asano, Kosuke; Komatsu, Yoshiko; Takagi, Katsuhiro; Ono, Moe; Tanaka, Takashi; Tomita, Koji; Haneishi, Ayumi; Tsukada, Akiko; Yamada, Kazuya

    2017-02-01

    The rat enhancer of split- and hairy-related protein-2 (SHARP-2) is an insulin-inducible transcription factor which represses transcription of the rat phosphoenolpyruvate carboxykinase gene. In this study, a regulatory mechanism of the SHARP-2 mRNA level by insulin was analyzed. Insulin rapidly induced the level of SHARP-2 mRNA. This induction was blocked by inhibitors for phosphoinositide 3-kinase (PI 3-K), protein kinase C (PKC), and mammalian target of rapamycin (mTOR), actinomycin D, and cycloheximide. Whereas an adenovirus infection expressing a dominant negative form of atypical PKC lambda (aPKCλ) blocked the insulin-induction of the SHARP-2 mRNA level, insulin rapidly activated the mTOR. Insulin did not enhance transcriptional activity from a 3.7 kb upstream region of the rat SHARP-2 gene. Thus, we conclude that insulin induces the expression of the rat SHARP-2 gene at the transcription level via both a PI 3-K/aPKCλ- and a PI 3-K/mTOR- pathways and that protein synthesis is required for this induction.

  6. Audit of sharp weapon deaths in metropolis of Karachi--an autopsy based study.

    PubMed

    Mirza, Farhat Hussain; Hasan, Qudsia; Memon, Akhtar Amin; Adil, Syeda Ezz-e-Rukhshan

    2010-01-01

    Sharp weapons are one of the most violent and abhorrent means of deaths. This study assesses the frequency of sharp weapon deaths in Karachi. This was a cross sectional study, and involves the deaths by sharp weapons autopsied in Karachi during Mar 2008-Feb 2009. This study reports that the frequency of sharp weapon deaths in Karachi is similar to some other studies conducted in different regions of Pakistan, yet it is very high as the population of Karachi is way more than any other metropolis of Pakistan. Our study reported that out of 2090 medico-legal deaths in Karachi during the study period, 91 deaths were due to sharp weapons, including 73 (80.2%) males and 18 (19.8%) females. 100% of the deaths were homicides, so none were suicides. Deaths were more frequent in age group ranging from 20-39 years (59.3%). Sharp weapon deaths continue to be a means of quite a number of deaths in Karachi. Such violence depicts intolerant and frustrated nature of the citizens.

  7. Sumoylation of the Basic Helix-Loop-Helix Transcription Factor Sharp-1 Regulates Recruitment of the Histone Methyltransferase G9a and Function in Myogenesis*

    PubMed Central

    Wang, Yaju; Shankar, Shilpa Rani; Kher, Devaki; Ling, Belinda Mei Tze; Taneja, Reshma

    2013-01-01

    Sumoylation is an important post-translational modification that alters the activity of many transcription factors. However, the mechanisms that link sumoylation to alterations in chromatin structure, which culminate in tissue specific gene expression, are not fully understood. In this study, we demonstrate that SUMO modification of the transcription factor Sharp-1 is required for its full transcriptional repression activity and function as an inhibitor of skeletal muscle differentiation. Sharp-1 is modified by sumoylation at two conserved lysine residues 240 and 255. Mutation of these SUMO acceptor sites in Sharp-1 does not impact its subcellular localization but attenuates its ability to act as a transcriptional repressor and inhibit myogenic differentiation. Consistently, co-expression of the SUMO protease SENP1 with wild type Sharp-1 abrogates Sharp-1-dependent inhibition of myogenesis. Interestingly, sumoylation acts as a signal for recruitment of the co-repressor G9a. Thus, enrichment of G9a, and histone H3 lysine 9 dimethylation (H3K9me2), a signature of G9a activity, is dramatically reduced at muscle promoters in cells expressing sumoylation-defective Sharp-1. Our findings demonstrate how sumoylation of Sharp-1 exerts an impact on chromatin structure and transcriptional repression of muscle gene expression through recruitment of G9a. PMID:23637228

  8. Confirmation of the Factor Structure and Measurement Invariance of the Children's Scale of Hostility and Aggression: Reactive/Proactive in Clinic-Referred Children With and Without Autism Spectrum Disorder.

    PubMed

    Farmer, Cristan A; Kaat, Aaron J; Mazurek, Micah O; Lainhart, Janet E; DeWitt, Mary Beth; Cook, Edwin H; Butter, Eric M; Aman, Michael G

    2016-02-01

    The measurement of aggression in its different forms (e.g., physical and verbal) and functions (e.g., impulsive and instrumental) is given little attention in subjects with developmental disabilities (DD). In this study, we confirm the factor structure of the Children's Scale for Hostility and Aggression: Reactive/Proactive (C-SHARP) and demonstrate measurement invariance (consistent performance across clinical groups) between clinic-referred groups with and without autism spectrum disorder (ASD). We also provide evidence of the construct validity of the C-SHARP. Caregivers provided C-SHARP, Child Behavior Checklist (CBCL), and Proactive/Reactive Rating Scale (PRRS) ratings for 644 children, adolescents, and young adults 2-21 years of age. Five types of measurement invariance were evaluated within a confirmatory factor analytic framework. Associations among the C-SHARP, CBCL, and PRRS were explored. The factor structure of the C-SHARP had a good fit to the data from both groups, and strict measurement invariance between ASD and non-ASD groups was demonstrated (i.e., equivalent structure, factor loadings, item intercepts and residuals, and latent variance/covariance between groups). The C-SHARP Problem Scale was more strongly associated with CBCL Externalizing than with CBCL Internalizing, supporting its construct validity. Subjects classified with the PRRS as both Reactive and Proactive had significantly higher C-SHARP Proactive Scores than those classified as Reactive only, who were rated significantly higher than those classified by the PRRS as Neither Reactive nor Proactive. A similar pattern was observed for the C-SHARP Reactive Score. This study provided evidence of the validity of the C-SHARP through confirmation of its factor structure and its relationship with more established scales. The demonstration of measurement invariance demonstrates that differences in C-SHARP factor scores were the result of differences in the construct rather than to error or unmeasured/nuisance variables. These data suggest that the C-SHARP is useful for quantifying subtypes of aggressive behavior in children, adolescents, and young adults with DD.

  9. Randomized controlled study of excimer laser atherectomy for treatment of femoropopliteal in-stent restenosis: initial results from the EXCITE ISR trial (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis).

    PubMed

    Dippel, Eric J; Makam, Prakash; Kovach, Richard; George, Jon C; Patlola, Raghotham; Metzger, D Christopher; Mena-Hurtado, Carlos; Beasley, Robert; Soukas, Peter; Colon-Hernandez, Pedro J; Stark, Matthew A; Walker, Craig

    2015-01-01

    The purpose of this study was to evaluate the safety and efficacy of excimer laser atherectomy (ELA) with adjunctive percutaneous transluminal angioplasty (PTA) versus PTA alone for treating patients with chronic peripheral artery disease with femoropopliteal bare nitinol in-stent restenosis (ISR). Femoropopliteal stenting has shown superiority to PTA for lifestyle-limiting claudication and critical limb ischemia, although treating post-stenting artery reobstruction, or ISR, remains challenging. The multicenter, prospective, randomized, controlled EXCITE ISR (EXCImer Laser Randomized Controlled Study for Treatment of FemoropopliTEal In-Stent Restenosis) trial was conducted across 40 U.S. centers. Patients with Rutherford Class 1 to 4 and lesions of target lesion length ≥4 cm, vessel diameter 5 to 7 mm were enrolled and randomly divided into ELA + PTA and PTA groups by a 2:1 ratio. The primary efficacy endpoint was target lesion revascularization (TLR) at 6-month follow up. The primary safety endpoint was major adverse event (death, amputation, or TLR) at 30 days post-procedure. Study enrollment was stopped at 250 patients due to early efficacy demonstrated at a prospectively-specified interim analysis. A total of 169 ELA + PTA subjects (62.7% male; mean age 68.5 ± 9.8 years) and 81 PTA patients (61.7% male; mean age 67.8 ± 10.3 years) were enrolled. Mean lesion length was 19.6 ± 12.0 cm versus 19.3 ± 11.9 cm, and 30.5% versus 36.8% of patients exhibited total occlusion. ELA + PTA subjects demonstrated superior procedural success (93.5% vs. 82.7%; p = 0.01) with significantly fewer procedural complications. ELA + PTA and PTA subject 6-month freedom from TLR was 73.5% versus 51.8% (p < 0.005), and 30-day major adverse event rates were 5.8% versus 20.5% (p < 0.001), respectively. ELA + PTA was associated with a 52% reduction in TLR (hazard ratio: 0.48; 95% confidence interval: 0.31 to 0.74). The EXCITE ISR trial is the first large, prospective, randomized study to demonstrate superiority of ELA + PTA versus PTA alone for treating femoropopliteal ISR. (Randomized Study of Laser and Balloon Angioplasty Versus Balloon Angioplasty to Treat Peripheral In-stent Restenosis [EXCITE ISR]; NCT01330628). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Laser induced local modification of magnetic domain in Co/Pt multilayer

    NASA Astrophysics Data System (ADS)

    Talapatra, A.; Mohanty, J.

    2016-11-01

    Manipulation of magnetic system by the use of laser has drawn the attention of contemporary research. We demonstrate here the modification of magnetic domain in perpendicularly magnetized Co/Pt multilayer by using ultrashort laser pulse. The as-prepared sample shows an out-of-plane saturation magnetic field of 803.4 mT and almost zero remanence with a labyrinth-like domain pattern at room temperature. Atomistic simulation showed that interaction with femto-second laser results in demagnetization of the material in 200 fs followed by a slower recovery. As it indicates a net loss in magnetization, so magnetic force microscopy is carried out to investigate the equilibrium state after the system is relaxed. Demagnetized random domains appeared at the centre of the laser spot with having a rim at the boundary which signifies a deterministic switching with respect to the neighbouring area. Rotation of domains at the central area with the application of small transverse field (100 mT) proves the region to be magnetically weaker. Systematic 3D micromagnetic simulation has been performed to model the laser induced change by selective reduction of anisotropy which is discussed in detail. This shows shrinking of domains to a near circular pattern to minimize the magnetostatic energy. 50% reduction in anisotropy energy is observed with increasing the total energy of the system and a sharp increase in demagnetization energy also takes place simultaneously. This also satisfies the anisotropy in domain rotation with the application of transverse field.

  11. Morin-like spin canting in the magnetic CaFe{sub 5}O{sub 7} ferrite: A combined neutron and Mössbauer study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Delacotte, C.; Bréard, Y.; Caignaert, V.

    2017-03-15

    Magnetic structure of CaFe{sub 5}O{sub 7} ferrite has been studied jointly from neutron powder diffraction data and spectroscopic Mössbauer measurements in the thermal range from 5 to 500 K. This coupled work highlights three distinct magnetic domains around two specific temperatures: T{sub M}=125 K and T{sub N}=360 K. The latter corroborates the structural monoclinic-orthorhombic transition previously reported by transmission electron microscopy techniques and X-ray thermodiffractometry. Complementary heat capacity measurements have confirmed this first order transition with a sharp peak at 360 K. Interestingly, this large study has revealed a second magnetic transition associated to a spin rotation at 125 Kmore » similar to this one reported by Morin in α-Fe{sub 2}O{sub 3} hematite at T{sub M}=260 K. - Graphical abstract: Magnetic structure of CaFe{sub 5}O{sub 7} ferrite has been studied jointly from neutron powder diffraction data and spectroscopic Mössbauer measurements in the thermal range from 5 to 500 K. This coupled work highlights three distinct magnetic domains around two specific temperatures: T{sub M}=125 K and T{sub N}=360 K. Interestingly, this large study has revealed a magnetic transition associated to a spin rotation at 125 K similar to this one reported by Morin in α-Fe{sub 2}O{sub 3} hematite at T{sub M}=260 K.« less

  12. Multiwavelength Polarization of Rotation-Powered Pulsars

    NASA Technical Reports Server (NTRS)

    Harding, Alice K.; Kalapotharakos, Constantinos

    2017-01-01

    Polarization measurements provide strong constraints on models for emission from rotation-powered pulsars. We present multiwavelength polarization predictions showing that measurements over a range of frequencies can be particularly important for constraining the emission location, radiation mechanisms, and system geometry. The results assume a generic model for emission from the outer magnetosphere and current sheet in which optical to hard X-ray emission is produced by synchrotron radiation (SR) from electron-positron pairs and gamma-ray emission is produced by curvature radiation (CR) or SR from accelerating primary electrons. The magnetic field structure of a force-free magnetosphere is assumed and the phase-resolved and phase-averaged polarization is calculated in the frame of an inertial observer. We find that large position angle (PA) swings and deep depolarization dips occur during the light-curve peaks in all energy bands. For synchrotron emission, the polarization characteristics are strongly dependent on photon emission radius with larger, nearly 180deg, PA swings for emission outside the light cylinder (LC)‚ as the line of sight crosses the current sheet. The phase-averaged polarization degree for SR is less that 10% and around 20% for emission starting inside and outside the LC, respectively, while the polarization degree for CR is much larger, up to 40%-60%. Observing a sharp increase in polarization degree and a change in PA at the transition between X-ray and gamma-ray spectral components would indicate that CR is the gamma-ray emission mechanism.

  13. Adiabatic sweep pulses for earth's field NMR with a surface coil

    NASA Astrophysics Data System (ADS)

    Conradi, Mark S.; Altobelli, Stephen A.; Sowko, Nicholas J.; Conradi, Susan H.; Fukushima, Eiichi

    2018-03-01

    Adiabatic NMR sweep pulses are described for inversion and excitation in very low magnetic fields B0 and with broad distribution of excitation field amplitude B1. Two aspects distinguish the low field case: (1) when B1 is comparable to or greater than B0, the rotating field approximation fails and (2) inversion sweeps cannot extend to values well below the Larmor frequency because they would approach or pass through zero frequency. Three approaches to inversion are described. The first is a conventional tangent frequency sweep down to the Larmor frequency, a 180° phase shift, and a sweep back up to the starting frequency. The other two are combined frequency and amplitude sweeps covering a narrower frequency range; one is a symmetric sweep from above to below the Larmor frequency and the other uses a smooth decrease of B1 immediately before and after the 180° phase shift. These two AM/FM sweeps show excellent inversion efficiencies over a wide range of B1, a factor of 30 or more. We also demonstrate an excitation sweep that works well in the presence of the same wide range of B1. We show that the primary effect of the counter-rotating field (i.e., at low B0) is that the magnetization suffers large, periodic deviations from where it would be at large B0. Thus, successful sweep pulses must avoid any sharp features in the amplitude, phase, or frequency.

  14. Multiwavelength Polarization of Rotation-powered Pulsars

    NASA Astrophysics Data System (ADS)

    Harding, Alice K.; Kalapotharakos, Constantinos

    2017-05-01

    Polarization measurements provide strong constraints on models for emission from rotation-powered pulsars. We present multiwavelength polarization predictions showing that measurements over a range of frequencies can be particularly important for constraining the emission location, radiation mechanisms, and system geometry. The results assume a generic model for emission from the outer magnetosphere and current sheet in which optical to hard X-ray emission is produced by synchrotron radiation (SR) from electron-positron pairs and γ-ray emission is produced by curvature radiation (CR) or SR from accelerating primary electrons. The magnetic field structure of a force-free magnetosphere is assumed and the phase-resolved and phase-averaged polarization is calculated in the frame of an inertial observer. We find that large position angle (PA) swings and deep depolarization dips occur during the light-curve peaks in all energy bands. For synchrotron emission, the polarization characteristics are strongly dependent on photon emission radius with larger, nearly 180°, PA swings for emission outside the light cylinder (LC) as the line of sight crosses the current sheet. The phase-averaged polarization degree for SR is less that 10% and around 20% for emission starting inside and outside the LC, respectively, while the polarization degree for CR is much larger, up to 40%-60%. Observing a sharp increase in polarization degree and a change in PA at the transition between X-ray and γ-ray spectral components would indicate that CR is the γ-ray emission mechanism.

  15. Multiwavelength Polarization of Rotation-powered Pulsars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harding, Alice K.; Kalapotharakos, Constantinos

    Polarization measurements provide strong constraints on models for emission from rotation-powered pulsars. We present multiwavelength polarization predictions showing that measurements over a range of frequencies can be particularly important for constraining the emission location, radiation mechanisms, and system geometry. The results assume a generic model for emission from the outer magnetosphere and current sheet in which optical to hard X-ray emission is produced by synchrotron radiation (SR) from electron–positron pairs and γ -ray emission is produced by curvature radiation (CR) or SR from accelerating primary electrons. The magnetic field structure of a force-free magnetosphere is assumed and the phase-resolved andmore » phase-averaged polarization is calculated in the frame of an inertial observer. We find that large position angle (PA) swings and deep depolarization dips occur during the light-curve peaks in all energy bands. For synchrotron emission, the polarization characteristics are strongly dependent on photon emission radius with larger, nearly 180°, PA swings for emission outside the light cylinder (LC) as the line of sight crosses the current sheet. The phase-averaged polarization degree for SR is less that 10% and around 20% for emission starting inside and outside the LC, respectively, while the polarization degree for CR is much larger, up to 40%–60%. Observing a sharp increase in polarization degree and a change in PA at the transition between X-ray and γ -ray spectral components would indicate that CR is the γ -ray emission mechanism.« less

  16. The Sharpness of Blades Used in Dermatologic Surgery.

    PubMed

    Awadalla, Farah; Hexsel, Camile; Goldberg, Leonard H

    2016-01-01

    There are numerous blades available for use in dermatologic procedures. There are different advantages that are inhere.nt to different blades due to their shape and size. One aspect of the blade that is instrumental to its performance, but is not objectively defined, is sharpness. This information could be useful when choosing a blade for a particular procedure. This study aims to objectively define the sharpness of blades used in dermatologic surgery. The Sharpness Tester (Cutlery and Allied Trades Research Association, Sheffield, UK) was used to test the force in Newtons a blade requires to cut through a silicone cylinder. New blades were used to determine a standard for the sharpness of new blades. Blades used for surgery were tested to determine the sharpness after use. The sharpest blade is the double-edged razor blade (0.395 N) followed by the dermablade (0.46 N), plastic handled #15 (0.541 N), #15c (0.575 N), #10 (0.647 N), and the #15 blade (0.664 N). The sharpness of a blade is an important factor in its ability to perform a task and should be taken into account when choosing a particular blade for a particular procedure.

  17. Activity trends in young solar-type stars

    NASA Astrophysics Data System (ADS)

    Lehtinen, J.; Jetsu, L.; Hackman, T.; Kajatkari, P.; Henry, G. W.

    2016-04-01

    Aims: We study a sample of 21 young and active solar-type stars with spectral types ranging from late F to mid K and characterize the behaviour of their activity. Methods: We apply the continuous period search (CPS) time series analysis method on Johnson B- and V-band photometry of the sample stars, collected over a period of 16 to 27 years. Using the CPS method, we estimate the surface differential rotation and determine the existence and behaviour of active longitudes and activity cycles on the stars. We supplement the time series results by calculating new log R'HK = log F'HK/σTeff4 emission indices for the stars from high resolution spectroscopy. Results: The measurements of the photometric rotation period variations reveal a positive correlation between the relative differential rotation coefficient and the rotation period as k ∝ Prot1.36, but do not reveal any dependence of the differential rotation on the effective temperature of the stars. Secondary period searches reveal activity cycles in 18 of the stars and temporary or persistent active longitudes in 11 of them. The activity cycles fall into specific activity branches when examined in the log Prot/Pcyc vs. log Ro-1, where Ro-1 = 2Ωτc, or log Prot/Pcyc vs. log R'HK diagram. We find a new split into sub-branches within this diagram, indicating multiple simultaneously present cycle modes. Active longitudes appear to be present only on the more active stars. There is a sharp break at approximately log R'HK = -4.46 separating the less active stars with long-term axisymmetric spot distributions from the more active ones with non-axisymmetric configurations. In seven out of eleven of our stars with clearly detected long-term non-axisymmetric spot activity the estimated active longitude periods are significantly shorter than the mean photometric rotation periods. This systematic trend can be interpreted either as a sign of the active longitudes being sustained from a deeper level in the stellar interior than the individual spots or as azimuthal dynamo waves exhibiting prograde propagation. Based on observations made as part of the automated astronomy program at Tennessee State University and with the Nordic Optical Telescope, operated on the island of La Palma jointly by Denmark, Finland, Iceland, Norway, and Sweden, in the Spanish Observatorio del Roque de los Muchachos of the Instituto de Astrofisica de Canarias.Photometric data and results are only available at the CDS via anonymous ftp to http://cdsarc.u-strasbg.fr (ftp://130.79.128.5) or via http://cdsarc.u-strasbg.fr/viz-bin/qcat?J/A+A/588/A38

  18. High-angular-resolution NIR astronomy with large arrays (SHARP I and SHARP II)

    NASA Astrophysics Data System (ADS)

    Hofmann, Reiner; Brandl, Bernhard; Eckart, Andreas; Eisenhauer, Frank; Tacconi-Garman, Lowell E.

    1995-06-01

    SHARP I and SHARP II are near infrared cameras for high-angular-resolution imaging. Both cameras are built around a 256 X 256 pixel NICMOS 3 HgCdTe array from Rockwell which is sensitive in the 1 - 2.5 micrometers range. With a 0.05'/pixel scale, they can produce diffraction limited K-band images at 4-m-class telescopes. For a 256 X 256 array, this pixel scale results in a field of view of 12.8' X 12.8' which is well suited for the observation of galactic and extragalactic near-infrared sources. Photometric and low resolution spectroscopic capabilities are added by photometric band filters (J, H, K), narrow band filters ((lambda) /(Delta) (lambda) approximately equals 100) for selected spectral lines, and a CVF ((lambda) /(Delta) (lambda) approximately equals 70). A cold shutter permits short exposure times down to about 10 ms. The data acquisition electronics permanently accepts the maximum frame rate of 8 Hz which is defined by the detector time constants (data rate 1 Mbyte/s). SHARP I has been especially designed for speckle observations at ESO's 3.5 m New Technology Telescope and is in operation since 1991. SHARP II is used at ESO's 3.6 m telescope together with the adaptive optics system COME-ON + since 1993. A new version of SHARP II is presently under test, which incorporates exchangeable camera optics for observations with scales of 0.035, 0.05, and 0.1'/pixel. The first scale extends diffraction limited observations down to the J-band, while the last one provides a larger field of view. To demonstrate the power of the cameras, images of the galactic center obtained with SHARP I, and images of the R136 region in 30 Doradus observed with SHARP II are presented.

  19. The risk of capsular breakage from phacoemulsification needle contact with the lens capsule: a laboratory study.

    PubMed

    Meyer, Jay J; Kuo, Annie F; Olson, Randall J

    2010-06-01

    To determine capsular breakage risk from contact by phacoemulsification needles by machine and tip type. Experimental laboratory investigation. Infiniti (Alcon, Inc.) with Intrepid cartridges and Signature (Abbott Medical Optics, Inc.) phacoemulsification machines were tested using 19- and 20-gauge sharp and rounded tips. Actual and unoccluded flow vacuum were determined at 550 mm Hg, bottle height of 75 cm, and machine-indicated flow rate of 60 mL/minute. Breakage from brief tip contact with a capsular surrogate and human cadaveric lenses was calculated. Nineteen-gauge tips had more flow and less unoccluded flow vacuum than 20-gauge tips for both machines, with highest unoccluded flow vacuum in the Infiniti. The 19-gauge sharp tip was more likely than the 20-gauge sharp tip to cause surrogate breakage for Signature with micropulse and Ellips (Abbott Medical Optics, Inc.) ultrasound at 100% power. For Infiniti using OZil (Alcon, Inc.) ultrasound, 20-gauge sharp tips were more likely than 19-gauge sharp tips to break the membrane. For cadaveric lenses, using rounded 20-gauge tips at 100% power, breakage rates were micropulse (2.3%), Ellips (2.3%), OZil (5.3%). Breakage rates for sharp 20-gauge Ellips tips were higher than for rounded tips. Factors influencing capsular breakage may include active vacuum at the tip, flow rate, needle gauge, and sharpness. Nineteen-gauge sharp tips were more likely than 20-gauge tips to cause breakage in lower vacuum methods. For higher-vacuum methods, breakage is more likely with 20-gauge than with 19-gauge tips. Rounded-edge tips are less likely than sharp-edged tips to cause breakage. Copyright 2010 Elsevier Inc. All rights reserved.

  20. SHARP Multiphysics Tutorials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Y. Q.; Shemon, E. R.; Mahadevan, Vijay S.

    SHARP, developed under the NEAMS Reactor Product Line, is an advanced modeling and simulation toolkit for the analysis of advanced nuclear reactors. SHARP is comprised of three physics modules currently including neutronics, thermal hydraulics, and structural mechanics. SHARP empowers designers to produce accurate results for modeling physical phenomena that have been identified as important for nuclear reactor analysis. SHARP can use existing physics codes and take advantage of existing infrastructure capabilities in the MOAB framework and the coupling driver/solver library, the Coupled Physics Environment (CouPE), which utilizes the widely used, scalable PETSc library. This report aims at identifying the coupled-physicsmore » simulation capability of SHARP by introducing the demonstration example called sahex in advance of the SHARP release expected by Mar 2016. sahex consists of 6 fuel pins with cladding, 1 control rod, sodium coolant and an outer duct wall that encloses all the other components. This example is carefully chosen to demonstrate the proof of concept for solving more complex demonstration examples such as EBR II assembly and ABTR full core. The workflow of preparing the input files, running the case and analyzing the results is demonstrated in this report. Moreover, an extension of the sahex model called sahex_core, which adds six homogenized neighboring assemblies to the full heterogeneous sahex model, is presented to test homogenization capabilities in both Nek5000 and PROTEUS. Some primary information on the configuration and build aspects for the SHARP toolkit, which includes capability to auto-download dependencies and configure/install with optimal flags in an architecture-aware fashion, is also covered by this report. A step-by-step instruction is provided to help users to create their cases. Details on these processes will be provided in the SHARP user manual that will accompany the first release.« less

  1. Lithium and Isotopic Ratio Li6/Li7 in Magnetic roAp Stars as an Indicator of Active Processes

    NASA Astrophysics Data System (ADS)

    Polosukhina, N.; Shavrina, A.; Lyashko, D.; Nesvacil, N.; Drake, N.; Smirnova, M.

    2015-04-01

    The lines of lithium at 6708 Å and 6103 Å are analyzed in high resolution spectra of some sharp-lined and slowly rotating roAp stars. Three spectral synthesis codes— STARSP, ZEEMAN2, and SYNTHM—were used. New lines of rare earth elements (REE) from the DREAM database and the lines calculated on the basis of the NIST energy levels were included. Magnetic splitting and other line broadening processes were taken into account. For both lithium lines, the enhanced abundances of lithium in the atmospheres of the stars studied are obtained. The lithium abundance determined from the Li 6103 Å line is higher than that from the Li 6708 Å for all the stars. This may be evidence of vertical lithium stratification, abnormal temperature distribution, or unidentified blending of the 6103 Å line. Our work on two roAp stars, HD 83368 and HD 60435 (Shavrina et al. 2001) provides evidence of an enhanced lithium abundance near the magnetic-field poles. We can expect similar effects in the sharp-lined roAp stars. High lithium abundance for all the stars and the estimates of the 6Li/7Li ratio (0.2-0.5) can be explained by production of Li in the cosmic ray spallation reactions in the interstellar medium where the stars were born, and by preservation of the original 6Li and 7Li by strong magnetic fields of these stars. The values of the 6Li/7Li ratio expected from production by cosmic rays are about 0.5-0.8 (Knauth et al. 2003; Webber et al. 2002). New laboratory and theoretical gf-values for REE lines are necessary in order to refine our estimates of lithium abundances and the isotopic ratio.

  2. Tidal dissipation in a homogeneous spherical body. II. Three examples: Mercury, Io, and Kepler-10 b

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Makarov, Valeri V.; Efroimsky, Michael, E-mail: vvm@usno.navy.mil, E-mail: michael.efroimsky@usno.navy.mil

    In Efroimsky and Makarov (Paper I), we derived from the first principles a formula for the tidal heating rate in a homogeneous sphere, compared it with the previously used formulae, and noted the differences. Now we present case studies: Mercury, Kepler-10 b, and a triaxial Io. A sharp frequency dependence of k {sub 2}/Q near spin-orbit resonances yields a sharp dependence of k {sub 2}/Q (and, therefore, of tidal heating) upon the spin rate. Thereby physical libration plays a major role in tidal heating of synchronously rotating planets. The magnitude of libration in the spin rate being defined by themore » planet's triaxiality, the latter becomes a factor determining the dissipation rate. Other parameters equal, a strongly triaxial synchronized body generates more heat than a similar body of a more symmetrical shape. After an initially triaxial object melts and loses its triaxiality, dissipation becomes less intensive; the body can solidify, with the tidal bulge becoming a new figure with triaxiality lower than the original. We derive approximate expressions for the dissipation rate in a Maxwell planet with the Maxwell time longer than the inverse tidal frequency. The expressions derived pertain to the 1:1 and 3:2 resonances and a nonresonant case; so they are applicable to most close-in super-Earths detected. In these planets, the heating outside synchronism is weakly dependent on the eccentricity and obliquity, provided both these parameters's values are moderate. According to our calculation, Kepler-10 b could hardly survive the intensive tidal heating without being synchronized, circularized, and reshaped through a complete or partial melt-down.« less

  3. The remarkable eclipsing asynchronous AM Herculis binary RX J19402-1025

    NASA Technical Reports Server (NTRS)

    Patterson, Joseph; Skillman, David R.; Thorstensen, John; Hellier, Coel

    1995-01-01

    We report on two years of photometric and spectroscopic observation of the recently discovered AM Herculis star RX J19402-1025. A sharp eclipse feature is present in the optical and X-ray light curves, repeating with a period of 12116.290 +/- 0.003 s. The out-of-eclipse optical waveform contains approximately equal contributions from a signal at the same period and another signal at 12150 s. As these signals drift in and out of phase, the wave form of the light curve changes in a complex but predictable manner. After one entire 'supercycle' of 50 days (the beat period between the shorter periods), the light curve returns to its initial shape. We present long-term ephemerides for each of these periods. It is highly probable that the eclipse period is the underlying orbital period, while the magnetic white dwarf rotates with P = 12150 s. The eclipses appear to be eclipses of the white dwarf by the secondary star. But there is probably also a small obscuring effect from cold gas surrounding the secondary, especially on the orbit-leading side where the stream begins to fall towards the white dwarf. The latter hypothesis can account for several puzzling effects in this star, as well as the tendency among most AM Her stars for the sharp emission-line components to slightly precede the actual motion of the secondary. The presence of eclipses in an asynchronous AM Her star provides a marvelous opportunity to study how changes in the orientation of magnetic field lines affect the accretion flows. Repeated polarimetric light curves and high-resolution studies of the emission lines are now critical to exploit this potential.

  4. Antiferromagnetic Resonance and Terahertz Continuum in α-RuCl_{3}.

    PubMed

    Little, A; Wu, Liang; Lampen-Kelley, P; Banerjee, A; Patankar, S; Rees, D; Bridges, C A; Yan, J-Q; Mandrus, D; Nagler, S E; Orenstein, J

    2017-12-01

    We report measurements of optical absorption in the zigzag antiferromagnet α-RuCl_{3} as a function of temperature T, magnetic field B, and photon energy ℏω in the range ∼0.3-8.3 meV, using time-domain terahertz spectroscopy. Polarized measurements show that threefold rotational symmetry is broken in the honeycomb plane from 2 to 300 K. We find a sharp absorption peak at 2.56 meV upon cooling below the Néel temperature of 7 K at B=0 that we identify as the magnetic-dipole excitation of a zero-wave-vector magnon, or antiferromagnetic resonance (AFMR). With the application of B, the AFMR broadens and shifts to a lower frequency as long-range magnetic order is lost in a manner consistent with transitioning to a spin-disordered phase. From a direct, internally calibrated measurement of the AFMR spectral weight, we place an upper bound on the contribution to the dc susceptibility from a magnetic excitation continuum.

  5. Antiferromagnetic Resonance and Terahertz Continuum in α - RuCl 3

    DOE PAGES

    Little, A.; Wu, Liang; Lampen-Kelley, P.; ...

    2017-11-28

    We report measurements of optical absorption in the zigzag antiferromagnet α-RuCl 3 as a function of temperature T , magnetic field B , and photon energy ℏ ω in the range ~ 0.3 –8.3 meV, using time-domain terahertz spectroscopy. Polarized measurements show that threefold rotational symmetry is broken in the honeycomb plane from 2 to 300 K. We find a sharp absorption peak at 2.56 meV upon cooling below the Néel temperature of 7 K at B = 0 that we identify as the magnetic-dipole excitation of a zero-wave-vector magnon, or antiferromagnetic resonance (AFMR). With the application of B ,more » the AFMR broadens and shifts to a lower frequency as long-range magnetic order is lost in a manner consistent with transitioning to a spin-disordered phase. From a direct, internally calibrated measurement of the AFMR spectral weight, we place an upper bound on the contribution to the dc susceptibility from a magnetic excitation continuum.« less

  6. Running and tumbling with E. coli in polymeric solutions

    PubMed Central

    Patteson, A. E.; Gopinath, A.; Goulian, M.; Arratia, P. E.

    2015-01-01

    Run-and-tumble motility is widely used by swimming microorganisms including numerous prokaryotic and eukaryotic organisms. Here, we experimentally investigate the run-and-tumble dynamics of the bacterium E. coli in polymeric solutions. We find that even small amounts of polymer in solution can drastically change E. coli dynamics: cells tumble less and their velocity increases, leading to an enhancement in cell translational diffusion and a sharp decline in rotational diffusion. We show that suppression of tumbling is due to fluid viscosity while the enhancement in swimming speed is mainly due to fluid elasticity. Visualization of single fluorescently labeled DNA polymers reveals that the flow generated by individual E. coli is sufficiently strong to stretch polymer molecules and induce elastic stresses in the fluid, which in turn can act on the cell in such a way to enhance its transport. Our results show that the transport and spread of chemotactic cells can be independently modified and controlled by the fluid material properties. PMID:26507950

  7. Modeling Mars Cyclogenesis and Frontal Waves: Seasonal Variations and Implications on Dust Activity

    NASA Technical Reports Server (NTRS)

    Hollingsworth, J. L.; Kahre, M. A.

    2014-01-01

    Between late autumn through early spring,middle and high latitudes onMars exhibit strong equator-to-polemean temperature contrasts (i.e., "baroclinicity"). Data collected during the Viking era and observations from both the Mars Global Surveyor (MGS) and Mars Reconnaissance Orbiter (MRO) indicate that such strong baroclinicity supports vigorous, large-scale eastward traveling weather systems (i.e., transient synoptic period waves) [1, 2]. For a rapidly rotating, differentially heated, shallow atmosphere such as on Earth and Mars, these large-scale, extratropical weather disturbances are critical components of the global circulation. The wave-like disturbances serve as agents in the transport of heat and momentum between low and high latitudes of the planet. Through cyclonic/anticyclonic winds, intense shear deformations, contractions-dilatations in temperature and density, and sharp perturbations amongst atmospheric tracers (i.e., dust, volatiles (e.g., water vapor) and condensates (e.g., water-ice cloud particles)), Mars' extratropical weather systems have significant sub-synoptic scale ramifications by supporting atmospheric frontal waves (Fig. 1).

  8. The HD molecule in small and medium cages of clathrate hydrates: Quantum dynamics studied by neutron scattering measurements and computation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colognesi, Daniele; Celli, Milva; Ulivi, Lorenzo, E-mail: lorenzo.ulivi@isc.cnr.it

    2014-10-07

    We report inelastic neutron scattering (INS) measurements on molecular hydrogen deuteride (HD) trapped in binary cubic (sII) and hexagonal (sH) clathrate hydrates, performed at low temperature using two different neutron spectrometers in order to probe both energy and momentum transfer. The INS spectra of binary clathrate samples exhibit a rich structure containing sharp bands arising from both the rotational transitions and the rattling modes of the guest molecule. For the clathrates with sII structure, there is a very good agreement with the rigorous fully quantum simulations which account for the subtle effects of the anisotropy, angular and radial, of themore » host cage on the HD microscopic dynamics. The sH clathrate sample presents a much greater challenge, due to the uncertainties regarding the crystal structure, which is known only for similar crystals with different promoter, but nor for HD (or H{sub 2}) plus methyl tert-butyl ether (MTBE-d12)« less

  9. Extratropical Cyclogenesis and Frontal Waves on Mars: Influences on Dust, Weather and the Planet's climate

    NASA Technical Reports Server (NTRS)

    Hollingsworth, J. L.; Kahre, Melinda A.

    2012-01-01

    Between late autumn and early spring, middle and high latitudes on Mars exhibit strong equatortopole mean temperature contrasts (i.e., "baroclinicity"). Data collected during the Viking era and observations from both the Mars Global Surveyor (MGS) and Mars Reconnaissance Orbiter (MRO) indicate that this strong baroclinicity supports vigorous, large-scale eastward traveling weather systems (i.e., transient synoptic periodwaves) [1,2]. For a rapidly rotating, differentially heated, shallow atmosphere such as on Earth and Mars, these large-scale, extratropical weather disturbances are critical components of the global circulation. The wavelike disturbances act as agents in the transport of heat and momentum between low and high latitudes of the planet. Through cyclonic/anticyclonic winds, intense shear deformations, contractions-dilatations in temperature and density, and sharp perturbations amongst atmospheric tracers (i.e., dust, volatiles (e.g., water vapor) and condensates (e.g., water-ice cloud particles)), Mars extratropical weather systems have significant subsynoptic scale ramifications by supporting atmospheric frontal waves (Fig. 1).

  10. Asteroid spectral reflectivities.

    NASA Technical Reports Server (NTRS)

    Chapman, C. R.; Mccord, T. B.; Johnson, T. V.

    1973-01-01

    We measured spectral reflectivities (0.3-1.1 micron) for 32 asteroids. There are at least 14 different curve types. Common types are: (a) reddish curves with 10% absorptions near 0.95 micron or beyond 1.0 micron, due to Fe(2+) in minerals such as pyroxenes; (b) flat curves in the visible and near-IR with sharp decreases in the UV and (c) flat curves even into the UV. Several asteroids show probable color variations with rotation, especially 6 Hebe. A sample of 102 asteroids with reliably known colors is derived from the reflectivities and from earlier colorimetry. Several correlations of colors and spectral curve types with orbital and physical parameters are examined: (1) asteroids with large aphelia have flat reflectivities while those with small perihelia are mostly reddish, (2) curve types show evidence for clustering on an a vs e plot, with 0.95 micron bands occuring mainly for Mars-approaching asteroids, (3) no strong correlation exists between color and either proper eccentricity or proper inclination.

  11. Running and tumbling with E. coli in polymeric solutions

    NASA Astrophysics Data System (ADS)

    Patteson, A. E.; Gopinath, A.; Goulian, M.; Arratia, P. E.

    2015-10-01

    Run-and-tumble motility is widely used by swimming microorganisms including numerous prokaryotic and eukaryotic organisms. Here, we experimentally investigate the run-and-tumble dynamics of the bacterium E. coli in polymeric solutions. We find that even small amounts of polymer in solution can drastically change E. coli dynamics: cells tumble less and their velocity increases, leading to an enhancement in cell translational diffusion and a sharp decline in rotational diffusion. We show that suppression of tumbling is due to fluid viscosity while the enhancement in swimming speed is mainly due to fluid elasticity. Visualization of single fluorescently labeled DNA polymers reveals that the flow generated by individual E. coli is sufficiently strong to stretch polymer molecules and induce elastic stresses in the fluid, which in turn can act on the cell in such a way to enhance its transport. Our results show that the transport and spread of chemotactic cells can be independently modified and controlled by the fluid material properties.

  12. An electron spin resonance study of gamma-ray irradiated ginseng.

    PubMed

    Nakamura, Hideo; Ukai, Mitsuko; Shimoyama, Yuhei

    2006-03-13

    Using electron spin resonance (ESR) spectroscopy, we revealed the presence of four radical species in gamma-ray irradiated ginseng (Agaliaceae). Before irradiation, the representative ESR spectrum of ginseng is composed of a sextet centered at g = 2.0, a sharp singlet at the same g-value, and a singlet at about g = 4.0. The first one is attributable to a hyperfine (hf) signal of Mn2+ ion (hf constant: 7.4 mT). The second one is due to an organic free radical. The third one is originated from Fe3+. Upon gamma-ray irradiation, a new ESR (the fourth) signal was detectable in the vicinity of g = 2.0 region. The progressive saturation behaviors of the ESR signals at various microwave power levels were indicative of different relaxation time for those radicals. The anisotropic ESR spectra were detected by the angular rotation of the sample tube. This is due to the existence of anisotropic microcrystalline in the ginseng powder sample.

  13. Latitude dependence of solar wind velocity observed at not less than 1 AU

    NASA Technical Reports Server (NTRS)

    Mitchell, D. G.; Roelof, E. C.; Wolfe, J. H.

    1981-01-01

    The large-scale solar wind velocity structure in the outer heliosphere has been systematically analyzed for Carrington rotations 1587-1541 (March 1972 to April 1976). Spacecraft data were taken from Imp 7/8 at earth, Pioneer 6, 8, and 9 near 1 AU, and Pioneer 10 and 11 between 1.6 and 5 AU. Using the constant radial velocity solar wind approximation to map all of the velocity data to its high coronal emission heliolongitude, the velocity structure observed at different spacecraft was examined for latitudinal dependence and compared with coronal structure in soft X-rays and H-alpha absorption features. The constant radial velocity approximation usually remains self-consistent in decreasing or constant velocity solar wind out to 5 AU, enabling us to separate radial from latitudinal propagation effects. Several examples of sharp nonmeridional stream boundaries in interplanetary space (about 5 deg latitude in width), often directly associated with features in coronal X-rays and H-alpha were found.

  14. An electron spin resonance study of γ-ray irradiated ginseng

    NASA Astrophysics Data System (ADS)

    Nakamura, Hideo; Ukai, Mitsuko; Shimoyama, Yuhei

    2006-03-01

    Using electron spin resonance (ESR) spectroscopy, we revealed the presence of four radical species in γ-ray irradiated ginseng ( Agaliaceae). Before irradiation, the representative ESR spectrum of ginseng is composed of a sextet centered at g = 2.0, a sharp singlet at the same g-value, and a singlet at about g = 4.0. The first one is attributable to a hyperfine (hf) signal of Mn 2+ ion (hf constant: 7.4 mT). The second one is due to an organic free radical. The third one is originated from Fe 3+. Upon γ-ray irradiation, a new ESR (the fourth) signal was detectable in the vicinity of g = 2.0 region. The progressive saturation behaviors of the ESR signals at various microwave power levels were indicative of different relaxation time for those radicals. The anisotropic ESR spectra were detected by the angular rotation of the sample tube. This is due to the existence of anisotropic microcrystalline in the ginseng powder sample.

  15. Compact hybrid optoelectrical unit for image processing and recognition

    NASA Astrophysics Data System (ADS)

    Cheng, Gang; Jin, Guofan; Wu, Minxian; Liu, Haisong; He, Qingsheng; Yuan, ShiFu

    1998-07-01

    In this paper a compact opto-electric unit (CHOEU) for digital image processing and recognition is proposed. The central part of CHOEU is an incoherent optical correlator, which is realized with a SHARP QA-1200 8.4 inch active matrix TFT liquid crystal display panel which is used as two real-time spatial light modulators for both the input image and reference template. CHOEU can do two main processing works. One is digital filtering; the other is object matching. Using CHOEU an edge-detection operator is realized to extract the edges from the input images. Then the reprocessed images are sent into the object recognition unit for identifying the important targets. A novel template- matching method is proposed for gray-tome image recognition. A positive and negative cycle-encoding method is introduced to realize the absolute difference measurement pixel- matching on a correlator structure simply. The system has god fault-tolerance ability for rotation distortion, Gaussian noise disturbance or information losing. The experiments are given at the end of this paper.

  16. Infrared spectra of seeded hydrogen clusters: (para-H2)N-N2O and (ortho-H2)N-N2O, N = 2-13.

    PubMed

    Tang, Jian; McKellar, A R W

    2005-09-15

    High-resolution infrared spectra of clusters containing para-H2 and/or ortho-H2 and a single nitrous oxide molecule are studied in the 2225-cm(-1) region of the upsilon1 fundamental band of N2O. The clusters are formed in pulsed supersonic jet expansions from a cooled nozzle and probed using a tunable infrared diode laser spectrometer. The simple symmetric rotor-type spectra generally show no resolved K structure, with prominent Q-branch features for ortho-H2 but not para-H2 clusters. The observed vibrational shifts and rotational constants are reported. There is no obvious indication of superfluid effects for para-H2 clusters up to N=13. Sharp transitions due to even larger clusters are observed, but no definite assignments are possible. Mixed (para-H2)N-(ortho-H2)M-N2O cluster line positions can be well predicted by linear interpolation between the corresponding transitions of the pure clusters.

  17. Critical thickness investigation of magnetic properties in exchange-coupled bilayers

    NASA Astrophysics Data System (ADS)

    Rodríguez-Suárez, R. L.; Vilela-Leão, L. H.; Bueno, T.; Oliveira, A. B.; de Almeida, J. R. L.; Landeros, P.; Rezende, S. M.; Azevedo, A.

    2011-06-01

    We present a systematic investigation of the magnetic properties of two series of polycrystalline ferromagnetic-antiferromagnetic bilayers (FM-AF) of Ni81Fe19(10nm)/Ir20Mn80(tAF) grown by dc magnetron sputtering. One series was grown at an oblique angle of 50° and the other one was grown at 0°. Ferromagnetic resonance (FMR) was used to measure the exchange bias field HE, the rotatable anisotropy field HRA, and the FMR linewidth ΔH as a function of the antiferromagnetic layer thickness tAF. Three relaxation channels due to isotropic Gilbert damping, anisotropic two-magnon scattering, and mosaicity effects are simultaneously distinguished through the angular dependence of the FMR linewidth. In the regime of small IrMn layer thicknesses, not enough to establish the exchange bias anisotropy, the FMR linewidth shows a sharp peak due to the contribution of the two-magnon scattering mechanism. The results presented here are of general importance for understanding the dynamics of magnetization in the FM-AF structures.

  18. Maintaining knife sharpness in industrial meat cutting: A matter of knife or meat cutter ability.

    PubMed

    Karltun, J; Vogel, K; Bergstrand, M; Eklund, J

    2016-09-01

    Knife sharpness is imperative in meat cutting. The aim of this study was to compare the impact of knife blade steel quality with meat cutters' individual ability to maintain the cutting edge sharp in an industrial production setting. Twelve meat cutters in two different companies using three different knives during normal production were studied in this quasi-experimental study. Methods included were measuring knife cutting force before and after knife use, time knives were used, ratings of sharpness and discomfort and interviews. Results showed that the meat cutters' skill of maintaining sharpness during work had a much larger effect on knife sharpness during work than the knife steel differences. The ability was also related to feelings of discomfort and to physical exertion. It was found that meat cutters using more knives were more likely to suffer from discomfort in the upper limbs, which is a risk for developing MSD. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. NASA-Ames Summer High School Apprenticeship Research Program (SHARP)

    NASA Technical Reports Server (NTRS)

    Powell, P.

    1983-01-01

    The function of SHARP is to recognize high school juniors who have demonstrated unusually high promise for sucess in mathemtics and science. Twenty academically talented students who will be seniors in high school in September were chosen to participate in SHARP 83. Mentors were selected to provide students with first-hand experiences in a research and development environment in order that each student might try out his or her tentative professional career choice. Some special features of SHARP included field trips to private industries doing similar and related research, special lectures on topics of research here at ARC, individual and group counseling sessions, written research papers and oral reports, and primarily the opportunity to be exposed to the present frontiers in space exploration and research. The long-range goal of SHARP is to contribute to the future recruitment of needed scientists and engineers. This final report is summary of all the phases of the planning and implemenation of the 1983 Summer High School Apprenticeship Research Program (SHARP).

  20. Weapon Use in Korean Homicide: Differences Between Homicides Involving Sharp and Blunt Instruments.

    PubMed

    Park, Jisun; Son, Hyeonseo

    2017-10-23

    On the basis of information regarding 276 homicides committed in South Korea between 1987 and 2008, we compared offenders' and victims' characteristics, injury locations, weapon-related behavior, and offending behavior between homicides involving sharp and blunt instruments. The victims of sharp-force homicide were much younger relative to those of blunt-force homicide. In addition, homicides involving blunt instruments were more likely to be committed by offenders who lived with the victims. Most sharp-force homicides involved injuries to the torso, while blunt-force homicides involved mainly head injuries. Furthermore, perpetrators of sharp-force homicides tended to preselect their weapons, while those of blunt-force homicides were likely to use weapons of opportunity. Logistic regression analysis identified a number of factors, including injury location and body transportation, which significantly predicted weapon type. As this was the first South Korean study to compare sharp- and blunt-force homicides, the results have practical implications for homicide investigations. © 2017 American Academy of Forensic Sciences.

  1. Improvement in perception of image sharpness through the addition of noise and its relationship with memory texture

    NASA Astrophysics Data System (ADS)

    Wan, Xiazi; Kobayashi, Hiroyuki; Aoki, Naokazu

    2015-03-01

    In a preceding study, we investigated the effects of image noise on the perception of image sharpness using white noise, and one- and two-dimensional single-frequency sinusoidal patterns as stimuli. This study extends our preceding study by evaluating natural color images, rather than black-and-white patterns. The results showed that the effect of noise in improving image sharpness perception is more evident in blurred images than in sharp images. This is consistent with the results of the preceding study. In another preceding study, we proposed "memory texture" to explain the preferred granularity of images, as a concept similar to "memory color" for preferred color reproduction. We observed individual differences in type of memory texture for each object, that is, white or 1/f noise. This study discusses the relationship between improvement of sharpness perception by adding noise, and the memory texture, following its individual differences. We found that memory texture is one of the elements that affect sharpness perception.

  2. More about solar g modes

    NASA Astrophysics Data System (ADS)

    Fossat, E.; Schmider, F. X.

    2018-04-01

    Context. The detection of asymptotic solar g-mode parameters was the main goal of the GOLF instrument onboard the SOHO space observatory. This detection has recently been reported and has identified a rapid mean rotation of the solar core, with a one-week period, nearly four times faster than all the rest of the solar body, from the surface to the bottom of the radiative zone. Aim. We present here the detection of more g modes of higher degree, and a more precise estimation of all their parameters, which will have to be exploited as additional constraints in modeling the solar core. Methods: Having identified the period equidistance and the splitting of a large number of asymptotic g modes of degrees 1 and 2, we test a model of frequencies of these modes by a cross-correlation with the power spectrum from which they have been detected. It shows a high correlation peak at lag zero, showing that the model is hidden but present in the real spectrum. The model parameters can then be adjusted to optimize the position (at exactly zero lag) and the height of this correlation peak. The same method is then extended to the search for modes of degrees 3 and 4, which were not detected in the previous analysis. Results: g-mode parameters are optimally measured in similar-frequency bandwidths, ranging from 7 to 8 μHz at one end and all close to 30 μHz at the other end, for the degrees 1 to 4. They include the four asymptotic period equidistances, the slight departure from equidistance of the detected periods for l = 1 and l = 2, the measured amplitudes, functions of the degree and the tesseral order, and the splittings that will possibly constrain the estimated sharpness of the transition between the one-week mean rotation of the core and the almost four-week rotation of the radiative envelope. The g-mode periods themselves are crucial inputs in the solar core structure helioseismic investigation.

  3. The use of roving discs and orthogonal natural frequencies for crack identification and location in rotors

    NASA Astrophysics Data System (ADS)

    Haji, Zyad N.; Olutunde Oyadiji, S.

    2014-11-01

    A variety of approaches that have been developed for the identification and localisation of cracks in a rotor system, which exploit natural frequencies, require a finite element model to obtain the natural frequencies of the intact rotor as baseline data. In fact, such approaches can give erroneous results about the location and depth of a crack if an inaccurate finite element model is used to represent an uncracked model. A new approach for the identification and localisation of cracks in rotor systems, which does not require the use of the natural frequencies of an intact rotor as a baseline data, is presented in this paper. The approach, named orthogonal natural frequencies (ONFs), is based only on the natural frequencies of the non-rotating cracked rotor in the two lateral bending vibration x-z and y-z planes. The approach uses the cracked natural frequencies in the horizontal x-z plane as the reference data instead of the intact natural frequencies. Also, a roving disc is traversed along the rotor in order to enhance the dynamics of the rotor at the cracked locations. At each spatial location of the roving disc, the two ONFs of the rotor-disc system are determined from which the corresponding ONF ratio is computed. The ONF ratios are normalised by the maximum ONF ratio to obtain normalised orthogonal natural frequency curves (NONFCs). The non-rotating cracked rotor is simulated by the finite element method using the Bernoulli-Euler beam theory. The unique characteristics of the proposed approach are the sharp, notched peaks at the crack locations but rounded peaks at non-cracked locations. These features facilitate the unambiguous identification and locations of cracks in rotors. The effects of crack depth, crack location, and mass of a roving disc are investigated. The results show that the proposed method has a great potential in the identification and localisation of cracks in a non-rotating cracked rotor.

  4. Structure and Rotation of the Solar Interior: Initial Results from the MDI Medium-L Program

    NASA Technical Reports Server (NTRS)

    Kosovichev, A. G.; Schou, J.; Scherrer, P. H.; Bogart, R. S.; Bush, R. I.; Hoeksema, J. T.; Aloise, J.; Bacon, L.; Burnette, A.; DeForest, C.; hide

    1997-01-01

    The medium-l program of the Michelson Doppler Imager instrument on board SOHO provides continuous observations of oscillation modes of angular degree, l, from 0 to approximately 300. The data for the program are partly processed on board because only about 3% of MDI observations can be transmitted continuously to the ground. The on-board data processing, the main component of which is Gaussian-weighted binning, has been optimized to reduce the negative influence of spatial aliasing of the high-degree oscillation modes. The data processing is completed in a data analysis pipeline at the SOI Stanford Support Center to determine the mean multiplet frequencies and splitting coefficients. The initial results show that the noise in the medium-l oscillation power spectrum is substantially lower than in ground-based measurements. This enables us to detect lower amplitude modes and, thus, to extend the range of measured mode frequencies. This is important for inferring the Sun's internal structure and rotation. The MDI observations also reveal the asymmetry of oscillation spectral lines. The line asymmetries agree with the theory of mode excitation by acoustic sources localized in the upper convective boundary layer. The sound-speed profile inferred from the mean frequencies gives evidence for a sharp variation at the edge of the energy-generating core. The results also confirm the previous finding by the GONG (Gough et al., 1996) that, in a thin layer just beneath the convection zone, helium appears to be less abundant than predicted by theory. Inverting the multiplet frequency splittings from MDI, we detect significant rotational shear in this thin layer. This layer is likely to be the place where the solar dynamo operates. In order to understand how the Sun works, it is extremely important to observe the evolution of this transition layer throughout the 11-year activity cycle.

  5. Ground-based Characterization of Earth Quasi Satellite (469219) 2016 HO3

    NASA Astrophysics Data System (ADS)

    Reddy, Vishnu; Kuhn, Olga; Thirouin, Audrey; Conrad, Al; Malhotra, Renu; Sanchez, Juan A.; Veillet, Christian

    2017-10-01

    (469219) 2016 HO3 is a small, <100 meter-size, near-Earth object (NEO) that while orbiting the Sun, also appears to circle around the Earth just beyond the Hill sphere as a Earth quasi-satellite. Only five quasi-satellites have been discovered so far, but 2016 HO3 is the most stable of them. The provenance of this object is unknown. On timescales of many centuries, 2016 HO3 remains within 38-100 lunar distance from us making it a prime target for future robotic and human exploration, provided it can be established it is indeed a natural object. In an effort to constrain its rotation period and surface composition, we observed 2016 HO3 on April 14 and 18 2017 (UTC) with the Large Binocular Telescope (LBT) and the Discovery Channel Telescope (DCT). We derive a rotation period of about 28 minutes based on our lightcurve observations. We obtained low-resolution (R ˜ 150 - 500) spectra of 2016 HO3 on 2017 April 14 (UTC) using the pair of MODS spectrographs mounted at the direct Gregorian foci of the LBT, obtaining the entire spectrum from 0.39-0.97 microns simultaneously. The visible wavelength spectrum shows a sharp rise in reflectance between 0.4-0.65 microns with a broad plateau beyond. The scatter near 0.8 microns makes it challenging to confirm the presence of a silicate absorption band at ~1 micron. Color ratios derived from the spectrum all suggest an S taxonomic type. We also derive an updated diameter of 36 meters for 2016 HO3 using an absolute magnitude of 24.3 and S-type albedo of 0.25. The derived rotation period and the spectrum are not uncommon amongst small NEOs, suggesting that 2016 HO3 is a natural object of similar provenance to other small NEOs. NASA Near-Earth Object Observations Program Grant NNX17AJ19G (PI: Reddy) funded parts of this work.

  6. Intensity modulated operating mode of the rotating gamma system.

    PubMed

    Sengupta, Bishwambhar; Gulyas, Laszlo; Medlin, Donald; Koroknai, Tibor; Takacs, David; Filep, Gyorgy; Panko, Peter; Godo, Bence; Hollo, Tamas; Zheng, Xiao Ran; Fedorcsak, Imre; Dobai, Jozsef; Bognar, Laszlo; Takacs, Endre

    2018-05-01

    The purpose of this work was to explore two novel operation modalities of the rotating gamma systems (RGS) that could expand its clinical application to lesions in close proximity to critical organs at risk (OAR). The approach taken in this study consists of two components. First, a Geant4-based Monte Carlo (MC) simulation toolkit is used to model the dosimetric properties of the RGS Vertex 360™ for the normal, intensity modulated radiosurgery (IMRS), and speed modulated radiosurgery (SMRS) operation modalities. Second, the RGS Vertex 360™ at the Rotating Gamma Institute in Debrecen, Hungary is used to collect experimental data for the normal and IMRS operation modes. An ion chamber is used to record measurements of the absolute dose. The dose profiles are measured using Gafchromic EBT3 films positioned within a spherical water equivalent phantom. A strong dosimetric agreement between the measured and simulated dose profiles and penumbra was found for both the normal and IMRS operation modes for all collimator sizes (4, 8, 14, and 18 mm diameter). The simulated falloff and maximum dose regions agree better with the experimental results for the 4 and 8 mm diameter collimators. Although the falloff regions align well in the 14 and 18 mm collimators, the maximum dose regions have a larger difference. For the IMRS operation mode, the simulated and experimental dose distributions are ellipsoidal, where the short axis aligns with the blocked angles. Similarly, the simulated dose distributions for the SMRS operation mode also adopt an ellipsoidal shape, where the short axis aligns with the angles where the orbital speed is highest. For both modalities, the dose distribution is highly constrained with a sharper penumbra along the short axes. Dose modulation of the RGS can be achieved with the IMRS and SMRS modes. By providing a highly constrained dose distribution with a sharp penumbra, both modes could be clinically applicable for the treatment of lesions in close proximity to critical OARs. © 2018 American Association of Physicists in Medicine.

  7. Surface-enhanced Raman scattering on periodic metal nanotips with tunable sharpness.

    PubMed

    Linn, Nicholas C; Sun, Chih-Hung; Arya, Ajay; Jiang, Peng; Jiang, Bin

    2009-06-03

    This paper reports on a scalable bottom-up technology for producing periodic gold nanotips with tunable sharpness as surface-enhanced Raman scattering (SERS) substrates. Inverted silicon pyramidal pits, which are templated from non-close-packed colloidal crystals prepared by a spin-coating technology, are used as structural templates to replicate arrays of polymer nanopyramids with nanoscale sharp tips. The deposition of a thin layer of gold on the polymer nanopyramids leads to the formation of SERS-active substrates with a high enhancement factor (up to 10(8)). The thickness of the deposited metal determines the sharpness of the nanotips and the resulting Raman enhancement factor. Finite-element electromagnetic modeling shows that the nanotips can significantly enhance the local electromagnetic field and the sharpness of nanotips greatly affects the SERS enhancement.

  8. Relationship of intentional self-harm using sharp objects with depressive and dissociative tendencies in pre-adolescence-adolescence.

    PubMed

    Sho, Noriko; Oiji, Arata; Konno, Chizue; Toyohara, Koji; Minami, Tatsuya; Arai, Takashi; Seike, Yoji

    2009-06-01

    The objectives of the present study were to (i) evaluate the prevalence of children and adolescents who have engaged in intentional self-harm using a sharp object; and (ii) investigate the relationship between self-harm with sharp objects and depressive tendencies or dissociative tendencies. A total of 1938 students in grades 5-12 in Yokohama, Japan, were enrolled, and they completed anonymous self-report questionnaires including a question about intentional self-harm with a sharp object, the Depression Self-Rating Scale for Children (DSRSC) and the Adolescent Dissociative Experiences Scale (A-DES). The prevalence of self-harm using sharp object was 5.4% among male 5th-6th graders, 4.0% among female 5th-6th graders, 5.3% among male 7th-9th graders, 15.1% among female 7th-9th graders, 6.6% among male 10th-12th graders, and 9.6% among female 10th-12th graders. Categorical regression analysis showed that a small amount of variance in self-harm by sharp object was explained by DSRSC and A-DES scores. Self-harm with a sharp object was prevalent among pre-adolescents and adolescents and was associated with depressive and dissociative tendencies.

  9. The Helioseismic and Magnetic Imager (HMI) Vector Magnetic Field Pipeline: SHARPs - Space-Weather HMI Active Region Patches

    NASA Astrophysics Data System (ADS)

    Bobra, M. G.; Sun, X.; Hoeksema, J. T.; Turmon, M.; Liu, Y.; Hayashi, K.; Barnes, G.; Leka, K. D.

    2014-09-01

    A new data product from the Helioseismic and Magnetic Imager (HMI) onboard the Solar Dynamics Observatory (SDO) called Space-weather HMI Active Region Patches ( SHARPs) is now available. SDO/HMI is the first space-based instrument to map the full-disk photospheric vector magnetic field with high cadence and continuity. The SHARP data series provide maps in patches that encompass automatically tracked magnetic concentrations for their entire lifetime; map quantities include the photospheric vector magnetic field and its uncertainty, along with Doppler velocity, continuum intensity, and line-of-sight magnetic field. Furthermore, keywords in the SHARP data series provide several parameters that concisely characterize the magnetic-field distribution and its deviation from a potential-field configuration. These indices may be useful for active-region event forecasting and for identifying regions of interest. The indices are calculated per patch and are available on a twelve-minute cadence. Quick-look data are available within approximately three hours of observation; definitive science products are produced approximately five weeks later. SHARP data are available at jsoc.stanford.edu and maps are available in either of two different coordinate systems. This article describes the SHARP data products and presents examples of SHARP data and parameters.

  10. Geology of the Early Arikareean sharps formation on the Pine Ridge Indian Reservation and surrounding areas of South Dakota and Nebraska.

    PubMed

    McConnell, Thomas H; Dibenedetto, Joseph N

    2012-01-01

    Based on geologic mapping, measured sections, and lithologic correlations, the local features of the upper and lower type areas of the Early Arikareean (30.8-20.6 million years ago) Sharps Formation are revised and correlated. The Sharps Formation above the basal Rockyford Member is divided into two members of distinct lithotypes. The upper 233 feet of massive siltstones and sandy siltstones is named the Gooseneck Road Member. The middle member, 161 feet of eolian volcaniclastic siltstones with fluvially reworked volcaniclastic lenses and sandy siltstone sheets, is named the Wolff Camp Member. An ashey zone at the base of the Sharps Formation is described and defined as the Rockyford Ash Zone (RAZ) in the same stratigraphic position as the Nonpareil Ash Zone (NPAZ) in Nebraska. Widespread marker beds of fresh water limestones at 130 feet above the base of the Sharps Formation and a widespread reddish-brown clayey siltstone at 165 feet above the base of the Sharps Formation are described. The Brown Siltstone Beds of Nebraska are shown to be a southern correlative of the Wolff Camp Member and the Rockyford Member of the Sharps Formation. Early attempts to correlate strata in the Great Plains were slow in developing. Recognition of the implications of the paleomagnetic and lithologic correlations of this paper will provide an added datum assisting researchers in future biostratigraphic studies. Based on similar lithologies, the Sharps Formation, currently assigned to the Arikaree Group, should be reassigned to the White River Group.

  11. A comparison of coupled freshwater-saltwater sharp-interface and convective-dispersive models of saltwater intrusion in a layered aquifer system

    USGS Publications Warehouse

    Hill, Mary C.

    1988-01-01

    Simulated results of the coupled freshwater-saltwater sharp interface and convective-dispersive numerical models are compared by using steady-state cross-sectional simulations. The results indicate that in some aquifers the calculated sharp interface is located further landward than would be expected.

  12. Notes on distribution and ecology of Philonthus spinipes Sharp (Coleoptera: Staphylinidae) in the Polish Carpathians.

    PubMed

    Mazur, Andrzej; Guo, Wanyue; Górz, Andrzej

    2017-11-30

    Philonthus spinipes Sharp for the first time was described from East Asia (Sharp 1874). Presently the species occurs in the whole Palaearctic region. Original distribution of this species is difficult to define because it has obviously extended its distribution range westwards (Schillhammer 1999).

  13. Development of the Adult Scale of Hostility and Aggression: Reactive-Proactive (A-SHARP)

    ERIC Educational Resources Information Center

    Matlock, Scott Thomas; Aman, Michael G.

    2011-01-01

    In this study, the authors developed the Adult Scale of Hostility and Aggression Reactive-Proactive (A-SHARP). Sixty-one caregivers rated 512 individuals with intellectual and developmental disabilities on the A-SHARP. Exploratory factor analysis revealed 5 factors on the Problem Scale: (a) Verbal Aggression, (b) Physical Aggression, (c) Hostile…

  14. The Russian Way of War: Post Soviet Adaptations in the Russian Military

    DTIC Science & Technology

    2013-12-13

    226Thomas Goltz , Georgia Diary (London: M. E. Sharpe, 2006), 253. 227Pavel Felgenhauer, “After August 7: The Escalation of the Russian-Georgian War,” in The...Sharpe, 2009. Goltz , Thomas. Georgia Diary. London: M. E. Sharpe, 2006. Goytisolo, Juan. Landscapes of War: From Sarajevo to Chechnya. Translated

  15. Numerical analysis of mixing by sharp-edge-based acoustofluidic micromixer

    NASA Astrophysics Data System (ADS)

    Nama, Nitesh; Huang, Po-Hsun; Jun Huang, Tony; Costanzo, Francesco

    2015-11-01

    Recently, acoustically oscillated sharp-edges have been employed to realize rapid and homogeneous mixing at microscales (Huang, Lab on a Chip, 13, 2013). Here, we present a numerical model, qualitatively validated by experimental results, to analyze the acoustic mixing inside a sharp-edge-based micromixer. We extend our previous numerical model (Nama, Lab on a Chip, 14, 2014) to combine the Generalized Lagrangian Mean (GLM) theory with the convection-diffusion equation, while also allowing for the presence of a background flow as observed in a typical sharp-edge-based micromixer. We employ a perturbation approach to divide the flow variables into zeroth-, first- and second-order fields which are successively solved to obtain the Lagrangian mean velocity. The Langrangian mean velocity and the background flow velocity are further employed with the convection-diffusion equation to obtain the concentration profile. We characterize the effects of various operational and geometrical parameters to suggest potential design changes for improving the mixing performance of the sharp-edge-based micromixer. Lastly, we investigate the possibility of generation of a spatio-temporally controllable concentration gradient by placing sharp-edge structures inside the microchannel.

  16. SHARP: A multi-mission artificial intelligence system for spacecraft telemetry monitoring and diagnosis

    NASA Technical Reports Server (NTRS)

    Lawson, Denise L.; James, Mark L.

    1989-01-01

    The Spacecraft Health Automated Reasoning Prototype (SHARP) is a system designed to demonstrate automated health and status analysis for multi-mission spacecraft and ground data systems operations. Telecommunications link analysis of the Voyager 2 spacecraft is the initial focus for the SHARP system demonstration which will occur during Voyager's encounter with the planet Neptune in August, 1989, in parallel with real time Voyager operations. The SHARP system combines conventional computer science methodologies with artificial intelligence techniques to produce an effective method for detecting and analyzing potential spacecraft and ground systems problems. The system performs real time analysis of spacecraft and other related telemetry, and is also capable of examining data in historical context. A brief introduction is given to the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory. The current method of operation for monitoring the Voyager Telecommunications subsystem is described, and the difficulties associated with the existing technology are highlighted. The approach taken in the SHARP system to overcome the current limitations is also described, as well as both the conventional and artificial intelligence solutions developed in SHARP.

  17. A Note on Trader Sharpe Ratios

    PubMed Central

    Coates, John M.; Page, Lionel

    2009-01-01

    Traders in the financial world are assessed by the amount of money they make and, increasingly, by the amount of money they make per unit of risk taken, a measure known as the Sharpe Ratio. Little is known about the average Sharpe Ratio among traders, but the Efficient Market Hypothesis suggests that traders, like asset managers, should not outperform the broad market. Here we report the findings of a study conducted in the City of London which shows that a population of experienced traders attain Sharpe Ratios significantly higher than the broad market. To explain this anomaly we examine a surrogate marker of prenatal androgen exposure, the second-to-fourth finger length ratio (2D∶4D), which has previously been identified as predicting a trader's long term profitability. We find that it predicts the amount of risk taken by traders but not their Sharpe Ratios. We do, however, find that the traders' Sharpe Ratios increase markedly with the number of years they have traded, a result suggesting that learning plays a role in increasing the returns of traders. Our findings present anomalous data for the Efficient Markets Hypothesis. PMID:19946367

  18. SHARPs - A Near-Real-Time Space Weather Data Product from HMI

    NASA Astrophysics Data System (ADS)

    Bobra, M.; Turmon, M.; Baldner, C.; Sun, X.; Hoeksema, J. T.

    2012-12-01

    A data product from the Helioseismic and Magnetic Imager (HMI) on the Solar Dynamics Observatory (SDO), called Space-weather HMI Active Region Patches (SHARPs), is now available through the SDO Joint Science Operations Center (JSOC) and the Virtual Solar Observatory. SHARPs are magnetically active regions identified on the solar disk and tracked automatically in time. SHARP data are processed within a few hours of the observation time. The SHARP data series contains active region-sized disambiguated vector magnetic field data in both Lambert Cylindrical Equal-Area and CCD coordinates on a 12 minute cadence. The series also provides simultaneous HMI maps of the line-of-sight magnetic field, continuum intensity, and velocity on the same ~0.5 arc-second pixel grid. In addition, the SHARP data series provides space weather quantities computed on the inverted, disambiguated, and remapped data. The values for each tracked region are computed and updated in near real time. We present space weather results for several X-class flares; furthermore, we compare said space weather quantities with helioseismic quantities calculated using ring-diagram analysis.

  19. A note on trader Sharpe Ratios.

    PubMed

    Coates, John M; Page, Lionel

    2009-11-25

    Traders in the financial world are assessed by the amount of money they make and, increasingly, by the amount of money they make per unit of risk taken, a measure known as the Sharpe Ratio. Little is known about the average Sharpe Ratio among traders, but the Efficient Market Hypothesis suggests that traders, like asset managers, should not outperform the broad market. Here we report the findings of a study conducted in the City of London which shows that a population of experienced traders attain Sharpe Ratios significantly higher than the broad market. To explain this anomaly we examine a surrogate marker of prenatal androgen exposure, the second-to-fourth finger length ratio (2D:4D), which has previously been identified as predicting a trader's long term profitability. We find that it predicts the amount of risk taken by traders but not their Sharpe Ratios. We do, however, find that the traders' Sharpe Ratios increase markedly with the number of years they have traded, a result suggesting that learning plays a role in increasing the returns of traders. Our findings present anomalous data for the Efficient Markets Hypothesis.

  20. SHARP: A multi-mission AI system for spacecraft telemetry monitoring and diagnosis

    NASA Technical Reports Server (NTRS)

    Lawson, Denise L.; James, Mark L.

    1989-01-01

    The Spacecraft Health Automated Reasoning Prototype (SHARP) is a system designed to demonstrate automated health and status analysis for multi-mission spacecraft and ground data systems operations. Telecommunications link analysis of the Voyager II spacecraft is the initial focus for the SHARP system demonstration which will occur during Voyager's encounter with the planet Neptune in August, 1989, in parallel with real-time Voyager operations. The SHARP system combines conventional computer science methodologies with artificial intelligence techniques to produce an effective method for detecting and analyzing potential spacecraft and ground systems problems. The system performs real-time analysis of spacecraft and other related telemetry, and is also capable of examining data in historical context. A brief introduction is given to the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory. The current method of operation for monitoring the Voyager Telecommunications subsystem is described, and the difficulties associated with the existing technology are highlighted. The approach taken in the SHARP system to overcome the current limitations is also described, as well as both the conventional and artificial intelligence solutions developed in SHARP.

  1. How sharp is sharp? Towards quantification of the sharpness and penetration ability of kitchen knives used in stabbings.

    PubMed

    Hainsworth, S V; Delaney, R J; Rutty, G N

    2008-07-01

    Stabbing is the most common method for violent death in the UK. As part of their investigation, forensic pathologists are commonly asked to estimate or quantify the degree of force required to create a wound. The force required to penetrate the skin and body by a knife is a complex function of the sharpness of the knife, the area of the body and alignment with cleavage lines of the skin, the angle of attack and the relative movement of the person stabbing relative to the victim being stabbed. This makes it difficult for the forensic pathologist to give an objective answer to the question; hence, subjective estimations are often used. One area where some degree of quantification is more tractable is in assessing how sharp an implement (particularly a knife) is. This paper presents results of a systematic study of how the different aspects of knife geometry influence sharpness and presents a simple test for assessing knife sharpness using drop testing. The results show that the radius of the blunt edge at the tip is important for controlling the penetration ability of a kitchen knife. Using high-speed video, it also gives insight into the mechanism of knife penetration into the skin. The results of the study will aid pathologists in giving a more informed answer to the question of the degree of force used in stabbing.

  2. Absolute plate motion of Africa around Hawaii-Emperor bend time

    NASA Astrophysics Data System (ADS)

    Maher, S. M.; Wessel, P.; Müller, R. D.; Williams, S. E.; Harada, Y.

    2015-06-01

    Numerous regional plate reorganizations and the coeval ages of the Hawaiian Emperor bend (HEB) and Louisville bend of 50-47 Ma have been interpreted as a possible global tectonic plate reorganization at ˜chron 21 (47.9 Ma). Yet for a truly global event we would expect a contemporaneous change in Africa absolute plate motion (APM) reflected by physical evidence distributed on the Africa Plate. This evidence has been postulated to take the form of the Réunion-Mascarene bend which exhibits many HEB-like features, such as a large angular change close to ˜chron 21. However, the Réunion hotspot trail has recently been interpreted as a sequence of continental fragments with incidental hotspot volcanism. Here we show that the alternative Réunion-Mascarene Plateau trail can also satisfy the age progressions and geometry of other hotspot trails on the Africa Plate. The implied motion, suggesting a pivoting of Africa from 67 to 50 Ma, could explain the apparent bifurcation of the Tristan hotspot chain, the age reversals seen along the Walvis Ridge, the sharp curve of the Canary trail, and the diffuse nature of the St. Helena chain. To test this hypothesis further we made a new Africa APM model that extends back to ˜80 Ma using a modified version of the Hybrid Polygonal Finite Rotation Method. This method uses seamount chains and their associated hotspots as geometric constraints for the model, and seamount age dates to determine APM through time. While this model successfully explains many of the volcanic features, it implies an unrealistically fast global lithospheric net rotation, as well as improbable APM trajectories for many other plates, including the Americas, Eurasia and Australia. We contrast this speculative model with a more conventional model in which the Mascarene Plateau is excluded in favour of the Chagos-Laccadive Ridge rotated into the Africa reference frame. This second model implies more realistic net lithospheric rotation and far-field APMs, but fails to explain key details of the Atlantic Ocean volcanic chains. Both models predict a Canary plume influence beneath the Madeiras. Neither model, when projected via the global plate circuit into the Pacific, predicts any significant change in plate motion around chron 21. Consequently, Africa APM models do not appear to provide independent support for a chron 21 global reorganization.

  3. Large Vertical Axis Rotations along Neotethyan Sutures in TURKEY

    NASA Astrophysics Data System (ADS)

    Ozkaptan, M.; Gulyuz, E.; Kaymakci, N.; Langereis, C. G.; Ozacar, A. A.; Lefebvre, C.

    2014-12-01

    Two Neotethyan Sutures,Izmir-Ankara and Intra-Tauride suture zones meet around Ankara region appx. at right angles.The northerly located Izmir-Ankara Suture zone follows approximately E-W trend and it makes a sharp approximately 90° bend at the east along the western margin of the Çankiri Basin.The Intra-Tauride suture follows approximately the Tuzgölü Fault Zone and trends NW-SE and seems to be overprinted by the structures related to the Izmir-Ankara suture zone. These two sutures meet southeastern corner of the Haymana Basin where the basin makes major eastwards counterclockwise bend.From west to East, the Haymana, Tuzgölü and Çankiri Basins straddle these suture zones and are developed in relation to the subduction and collision processes in the region, making them the perfect sites to unravel deformation history and paleogeography of the Neotethyan suture zones in the region. In order to accomplish this, the tectono-stratigraphic evolution of the basin and its paleogeographical positions, in different time slices, constructed by conducting a very detailed study on the Late Cretaceous to Recent infill of the Haymana, Tuzgölü, and Çankiri Basins. We collected more than 4500 sedimentary paleomagnetic samples for paleomagnetic purposes from 112 different locations within 250 km diameter area.Before the demagnetization process, nearly 3000 core specimens were measured for anisotropy of magnetic susceptibility (AMS) in order to understand deformation amounts and kinematics.The paleomagnetic results show that the region underwent strong clockwise and counterclockwise rotations more than 90° in places, resulting in the present geometry of the suture zones. The central part of the Haymana basin rotated as high as 90° counterclockwise while its northern part together with the southwestern part of the Çankiri basin and northern part of the Tuzgölü basin rotated approximately 30° clockwise contrary to almost all published paleomagnetic data from the region.The restored orientations based on this new paleomagnetic data indicate that Haymana, Tuzgölü Basin and the SW margin of the Çankiri basins were initially oriented N-S prior to Eocene.These results indicate that the most of the paleogeographical maps and evolutionary scenarios and models of the region requires major re-thinking and serious revisions.

  4. Wind Variability of B Supergiants. No. 2; The Two-component Stellar Wind of gamma Arae

    NASA Technical Reports Server (NTRS)

    Prinja, R. K.; Massa, D.; Fullerton, A. W.; Howarth, I. D.; Pontefract, M.

    1996-01-01

    The stellar wind of the rapidly rotating early-B supergiant, gamma Ara, is studied using time series, high-resolution IUE spectroscopy secured over approx. 6 days in 1993 March. Results are presented based on an analysis of several line species, including N(N), C(IV), Si(IV), Si(III), C(II), and Al(III). The wind of this star is grossly structured, with evidence for latitude-dependent mass loss which reflects the role of rapid rotation. Independent, co-existing time variable features are identified at low-velocity (redward of approx. -750 km/s) and at higher-speeds extending to approx. -1500 km/s. The interface between these structures is 'defined' by the appearance of a discrete absorption component which is extremely sharp (in velocity space). The central velocity of this 'Super DAC' changes only gradually, over several days, between approx. -400 and -750 km/s in most of the ions. However, its location is shifted redward by almost 400 km/s in Al(III) and C(II), indicating that the physical structure giving rise to this feature has a substantial velocity and ionization jump. Constraints on the relative ionization properties of the wind structures are discussed, together with results based on SEI line-profile-fitting methods. The overall wind activity in gamma Ara exhibits a clear ion dependence, such that low-speed features are promoted in low-ionization species, including Al(III), C(II), and Si(III). We also highlight that - in contrast to most OB stars - there are substantial differences in the epoch-to-epoch time-averaged wind profiles of gamma Ara. We interpret the results in terms of a two-component wind model for gamma Ara, with an equatorially compressed low ionization region, and a high speed, higher-ionization polar outflow. This picture is discussed in the context of the predicted bi-stability mechanism for line-driven winds in rapidly rotating early-B type stars, and the formation of compressed wind regions in rapidly rotating hot stars. The apparent absence of a substantial shift in the wind ionization mixture of gamma Ara, and the normal nature of its photospheric spectrum, suggests wind-compression as the likely dominant cause for the observed equatorial density enhancements.

  5. The Relevance of Culturally Based Curriculum and Instruction: The Case of Nancy Sharp

    ERIC Educational Resources Information Center

    Lipka, Jerry; Sharp, Nancy; Brenner, Betsy; Yanez, Evelyn; Sharp, Ferdinand

    2005-01-01

    Ms. Sharp's case is particularly instructive as it shows how this experienced Yup'ik teacher steeped in the traditions of her culture effectively implemented a culturally based math module. Ms. Sharp's pedagogical creatively allowed her to authentically bring together a core academic content area, math, with Yup'ik traditions, knowledge, and ways…

  6. Evaluating Continuing Education Needs and Program Effectiveness Using a Survey of Virginia's SHARP Logger Program Participants

    ERIC Educational Resources Information Center

    Barrett, Scott M.; Bolding, M. Chad; Munsell, John F.

    2012-01-01

    Virginia's SHARP logger program is a Cooperative Extension program currently providing training to over 1,500 loggers, foresters, and others. We conducted a mail survey of SHARP loggers to characterize program participants, assess programming needs, and evaluate program effectiveness. Results indicate a diverse group of participants in terms of…

  7. 78 FR 59425 - Proposed Collection: Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-26

    ... required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A). Currently the... Service, Bruce A. Sharp, 200 Third Street A4-A, Parkersburg, WV 26106-1328, or bruce.sharp@bpd.treas.gov... INFORMATION CONTACT: Requests for additional information or copies should be directed to Bruce A. Sharp...

  8. 77 FR 13176 - Proposed Collection: Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-05

    ... 104-13 (44 U.S.C. 3506(c)(2)(A). Currently the Bureau of the Public Debt within the Department of the.... Sharp, 200 Third Street A4-A, Parkersburg, WV 26106-1328, or bruce.sharp@bpd.treas.gov . The opportunity...: Requests for additional information or copies should be directed to Bruce A. Sharp, Bureau of the Public...

  9. 77 FR 31689 - Proposed Information Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-29

    ... required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A). Currently the.... Sharp, 200 Third Street A4-A, Parkersburg, WV 26106-1328, or bruce.sharp@bpd.treas.gov . The opportunity...: Requests for additional information or copies should be directed to Bruce A. Sharp, Bureau of the Public...

  10. 77 FR 32179 - Proposed Collection: Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A)). Currently the.... Sharp, 200 Third Street A4-A, Parkersburg, WV 26106-1328, or bruce.sharp@bpd.treas.gov . The opportunity...: Requests for additional information or copies should be directed to Bruce A. Sharp, Bureau of the Public...

  11. 78 FR 21706 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-11

    ... required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A). Currently the... Public Debt, Bruce A. Sharp, 200 Third Street A4-A, Parkersburg, WV 26106-1328, or bruce.sharp@bpd.treas... INFORMATION CONTACT: Requests for additional information or copies should be directed to Bruce A. Sharp...

  12. 77 FR 60026 - Proposed Collection: Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-01

    ... required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A). Currently the... Public Debt, Bruce A. Sharp, 200 Third Street A4-A, Parkersburg, WV 26106-1328, or bruce.sharp@bpd.treas... INFORMATION CONTACT: Requests for additional information or copies should be directed to Bruce A. Sharp...

  13. 77 FR 19424 - Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-30

    ..., as required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A..., Bruce A. Sharp, 200 Third Street A4-A, Parkersburg, WV 26106-1328, or bruce.sharp@bpd.treas.gov . The...: Requests for additional information or copies should be directed to Bruce A. Sharp, Bureau of the Public...

  14. 77 FR 32180 - Proposed Collection: Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A). Currently the... the Public Debt, Bruce A. Sharp, 200 Third Street A4-A, Parkersburg, WV 26106-1328, or bruce.sharp@bpd... INFORMATION CONTACT: Requests for additional information or copies should be directed to Bruce A. Sharp...

  15. The Formation and Erosion History of Mt. Sharp

    NASA Technical Reports Server (NTRS)

    Allen, Carlton C.; Dapremont, Angela M.

    2014-01-01

    The Curiosity rover is exploring 155 km diameter Gale crater and Mt. Sharp, Gale's 5 km high central mound (Fig. 1). This study addresses the formation and erosion history of Mt. Sharp. Gale lies on the topographic dichotomy between the southern highlands and the northern plains - a drop of over 2 km [1,2]. Altitude differences between the north and south rim reflect this regional slope, as do altitude differences between the deep annulus north of Mt. Sharp and the southern crater floor. Orbiter and rover images demonstrate that most exposed areas on Mt. Sharp consist of thin, sub-parallel units interpreted as sedimentary layers [3]. Gale is typical of the 50 large martian craters that have been totally or partially filled with such layers [4,5]. In many craters these sediments have been deeply eroded. Central Peak and Peak Ring: The highest point on Mt. Sharp, near the crater's center, is interpreted as a central peak [6]. The peak has a massive lower portion and a thin, smooth capping deposit (Fig. 2). Gale's size is transitional between martian craters with single central peaks and craters with peak rings approximately half the crater's diameter [2,6]. The boundaries of Mt. Sharp, as well as an arc of hills to the southeast of the mountain, closely match a circle approximately 80 km in diameter (Fig. 3). This morphology suggests that the Gale impact may have formed both a central peak and a partial peak ring, which is covered by the sediments of Mt. Sharp in the north and possibly exposed in the arc of eroded hills in the southeast quadrant (Figs. 3,4).

  16. A comprehensive numerical analysis of background phase correction with V-SHARP.

    PubMed

    Özbay, Pinar Senay; Deistung, Andreas; Feng, Xiang; Nanz, Daniel; Reichenbach, Jürgen Rainer; Schweser, Ferdinand

    2017-04-01

    Sophisticated harmonic artifact reduction for phase data (SHARP) is a method to remove background field contributions in MRI phase images, which is an essential processing step for quantitative susceptibility mapping (QSM). To perform SHARP, a spherical kernel radius and a regularization parameter need to be defined. In this study, we carried out an extensive analysis of the effect of these two parameters on the corrected phase images and on the reconstructed susceptibility maps. As a result of the dependence of the parameters on acquisition and processing characteristics, we propose a new SHARP scheme with generalized parameters. The new SHARP scheme uses a high-pass filtering approach to define the regularization parameter. We employed the variable-kernel SHARP (V-SHARP) approach, using different maximum radii (R m ) between 1 and 15 mm and varying regularization parameters (f) in a numerical brain model. The local root-mean-square error (RMSE) between the ground-truth, background-corrected field map and the results from SHARP decreased towards the center of the brain. RMSE of susceptibility maps calculated with a spatial domain algorithm was smallest for R m between 6 and 10 mm and f between 0 and 0.01 mm -1 , and for maps calculated with a Fourier domain algorithm for R m between 10 and 15 mm and f between 0 and 0.0091 mm -1 . We demonstrated and confirmed the new parameter scheme in vivo. The novel regularization scheme allows the use of the same regularization parameter irrespective of other imaging parameters, such as image resolution. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  17. Understanding the Hospital Sharps Injury Reporting Pathway

    PubMed Central

    Boden, Leslie I.; Petrofsky, Yolanta V.; Hopcia, Karen; Wagner, Gregory R.; Hashimoto, Dean

    2016-01-01

    Introduction Patient-care workers are frequently exposed to sharps injuries, which can involve the risk of serious illness. Underreporting of these injuries can compromise prevention efforts. Materials and Methods We linked survey responses of 1572 non-physician patient-care workers with the Occupational Health Services (OHS) database at two academic hospitals. We determined whether survey respondents who said they had sharps injuries indicated that they had reported them and whether reported injuries were recorded in the OHS database. Results Respondents said that they reported 62 of 78 sharps injuries occurring over a 12-month period. Only 28 appeared in the OHS data. Safety practices were positively associated with respondents’ saying they reported sharps injuries but not with whether reported injuries appeared in the OHS data. Conclusions Administrators should consider creating reporting mechanisms that are simpler and more direct. Administrators and researchers should attempt to understand how incidents might be lost before they are recorded. PMID:25308763

  18. Implementation of Structures in the CMS: Part 2, Weir

    DTIC Science & Technology

    2013-08-01

    sharp - crested weir , it is between 0.55 and 0.58, and a broad - crested ...implementation, different weir coefficients are specified for the weir structure design, sharp - crested or broad - crested weir . The lowest value in the...coefficient range is used for the sharp - crested (0.55) and broad - crested (0.46) weir , respectively; the flux comparison between these two

  19. 78 FR 60376 - Proposed Collection: Direct Deposit Sign-Up Form

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-01

    ..., as required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A... Fiscal Service, Bruce A. Sharp, 200 Third Street A4-A, Parkersburg, WV 26106-1328, or bruce.sharp@bpd.... Sharp, Bureau of the Fiscal Service, 200 Third Street A4-A, Parkersburg, WV 26106-1328, (304) 480- 8150...

  20. 77 FR 38394 - Proposed Collection: Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-27

    ... required by the Paperwork Reduction Act of 1995, Public Law 104-13 (44 U.S.C. 3506(c)(2)(A). Currently the... of the Public Debt, Bruce A. Sharp, 200 Third Street A4-A, Parkersburg, WV 26106-1328, or bruce.sharp.... Sharp, Bureau of the Public Debt, 200 Third Street A4-A, Parkersburg, WV 26106-1328, (304) 480-8150...

  1. Consideration of vision and picture quality: psychological effects induced by picture sharpness

    NASA Astrophysics Data System (ADS)

    Kusaka, Hideo

    1989-08-01

    A psychological hierarchy model of human vision(1)(2) suggests that the visual signals are processed in a serial manner from lower to higher stages: that is "sensation" - "perception" - "emotion." For designing a future television system, it is important to find out what kinds of physical factors affect the "emotion" experienced by an observer in front of the display. This paper describes the psychological effects induced by the sharpness of the picture. The subjective picture quality was evaluated for the same pictures with five different levels of sharpness. The experiment was performed on two kinds of printed pictures: (A) a woman's face, and (B) a town corner. From these experiments, it was found that the amount of high-frequency peaking (physical value of the sharpness) which psychologically gives the best picture quality, differs between pictures (A) and (B). That is, the optimum picture sharpness differs depending on the picture content. From these results, we have concluded that the psychophysical sharpness of the picture is not only determined at the stage of "perception" (e.g., resolution or signal to noise ratio, which everyone can judge immediately), but also at the stage of "emotion" (e.g., sensation of reality or beauty).

  2. Objective assessment of knife sharpness over a working day cutting meat.

    PubMed

    Savescu, Adriana; Cuny-Guerrier, Aude; Wild, Pascal; Reno, Gilles; Aublet-Cuvelier, Agnès; Claudon, Laurent

    2018-04-01

    Knife sharpness is one of multiple factors involved in musculoskeletal disorders in industrial meat cutting. The aim of this study was to objectively evaluate, in real working situations, how knife sharpness changed over a working day cutting meat, and to analyse the impact of sharpening, steeling and meat-cutting activities on these variations. Twenty-two meat-cutting workers from three different companies participated in the study. The methods included measurements of knife sharpness in relation to real work situations and consideration of the way meat-cutting and sharpening operations were organised. Results showed that the type of meat-cutting activities, the steeling strategy adopted by the worker, including the types of tool used, and the overall organisation of the sharpening task all had a significant influence on how knife sharpness evolved over a 2-h period and over an entire working day. To improve MSD prevention, sharpening and steeling operations should not be considered as independent activities, but taken into account as a continuity of working actions. Appropriate assessment of knife sharpness by meat cutters affects how they organise meat-cutting and sharpening tasks. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. A Sharp methodology for VLSI layout

    NASA Astrophysics Data System (ADS)

    Bapat, Shekhar

    1993-01-01

    The layout problem for VLSI circuits is recognized as a very difficult problem and has been traditionally decomposed into the several seemingly independent sub-problems of placement, global routing, and detailed routing. Although this structure achieves a reduction in programming complexity, it is also typically accompanied by a reduction in solution quality. Most current placement research recognizes that the separation is artificial, and that the placement and routing problems should be solved ideally in tandem. We propose a new interconnection model, Sharp and an associated partitioning algorithm. The Sharp interconnection model uses a partitioning shape that roughly resembles the musical sharp 'number sign' and makes extensive use of pre-computed rectilinear Steiner trees. The model is designed to generate strategic routing information along with the partitioning results. Additionally, the Sharp model also generates estimates of the routing congestion. We also propose the Sharp layout heuristic that solves the layout problem in its entirety. The Sharp layout heuristic makes extensive use of the Sharp partitioning model. The use of precomputed Steiner tree forms enables the method to model accurately net characteristics. For example, the Steiner tree forms can model both the length of the net and more importantly its route. In fact, the tree forms are also appropriate for modeling the timing delays of nets. The Sharp heuristic works to minimize both the total layout area by minimizing total net length (thus reducing the total wiring area), and the congestion imbalances in the various channels (thus reducing the unused or wasted channel area). Our heuristic uses circuit element movements amongst the different partitioning blocks and selection of alternate minimal Steiner tree forms to achieve this goal. The objective function for the algorithm can be modified readily to include other important circuit constraints like propagation delays. The layout technique first computes a very high-level approximation of the layout solution (i.e., the positions of the circuit elements and the associated net routes). The approximate solution is alternately refined, objective function. The technique creates well defined sub-problems and offers intermediary steps that can be solved in parallel, as well as a parallel mechanism to merge the sub-problem solutions.

  4. DIVERGENT HORIZONTAL SUB-SURFACE FLOWS WITHIN ACTIVE REGION 11158

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jain, Kiran; Tripathy, S. C.; Hill, F., E-mail: kjain@nso.edu, E-mail: stripathy@nso.edu, E-mail: fhill@nso.edu

    We measure the horizontal subsurface flow in a fast emerging active region (AR; NOAA 11158) using the ring-diagram technique and the Helioseismic and Magnetic Imager high spatial resolution Dopplergrams. This AR had a complex magnetic structure and displayed significant changes in morphology during its disk passage. Over a period of six days from 2011 February 11 to 16, the temporal variation in the magnitude of the total velocity is found to follow the trend of magnetic field strength. We further analyze regions of individual magnetic polarity within AR 11158 and find that the horizontal velocity components in these sub-regions havemore » significant variation with time and depth. The leading and trailing polarity regions move faster than the mixed-polarity region. Furthermore, both zonal and meridional components have opposite signs for trailing and leading polarity regions at all depths showing divergent flows within the AR. We also find a sharp decrease in the magnitude of total horizontal velocity in deeper layers around major flares. It is suggested that the re-organization of magnetic fields during flares, combined with the sunspot rotation, decreases the magnitude of horizontal flows or that the flow kinetic energy has been converted into the energy released by flares. After the decline in flare activity and sunspot rotation, the flows tend to follow the pattern of magnetic activity. We also observe less variation in the velocity components near the surface but these tend to increase with depth, further demonstrating that the deeper layers are more affected by the topology of ARs.« less

  5. Anisotropic non-gaussianity from rotational symmetry breaking excited initial states

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashoorioon, Amjad; Casadio, Roberto; Dipartimento di Fisica e Astronomia, Alma Mater Università di Bologna,via Irnerio 46, 40126 Bologna

    2016-12-01

    If the initial quantum state of the primordial perturbations broke rotational invariance, that would be seen as a statistical anisotropy in the angular correlations of the cosmic microwave background radiation (CMBR) temperature fluctuations. This can be described by a general parameterisation of the initial conditions that takes into account the possible direction-dependence of both the amplitude and the phase of particle creation during inflation. The leading effect in the CMBR two-point function is typically a quadrupole modulation, whose coefficient is analytically constrained here to be |B|≲0.06. The CMBR three-point function then acquires enhanced non-gaussianity, especially for the local configurations. Inmore » the large occupation number limit, a distinctive prediction is a modulation of the non-gaussianity around a mean value depending on the angle that short and long wavelength modes make with the preferred direction. The maximal variations with respect to the mean value occur for the configurations which are coplanar with the preferred direction and the amplitude of the non-gaussianity increases (decreases) for the short wavelength modes aligned with (perpendicular to) the preferred direction. For a high scale model of inflation with maximally pumped up isotropic occupation and ϵ≃0.01 the difference between these two configurations is about 0.27, which could be detectable in the future. For purely anisotropic particle creation, the non-Gaussianity can be larger and its anisotropic feature very sharp. The non-gaussianity can then reach f{sub NL}∼30 in the preferred direction while disappearing from the correlations in the orthogonal plane.« less

  6. Validation of Community Models: 2. Development of a Baseline, Using the Wang-Sheeley-Arge Model

    NASA Technical Reports Server (NTRS)

    MacNeice, Peter

    2009-01-01

    This paper is the second in a series providing independent validation of community models of the outer corona and inner heliosphere. Here I present a comprehensive validation of the Wang-Sheeley-Arge (WSA) model. These results will serve as a baseline against which to compare the next generation of comparable forecasting models. The WSA model is used by a number of agencies to predict Solar wind conditions at Earth up to 4 days into the future. Given its importance to both the research and forecasting communities, it is essential that its performance be measured systematically and independently. I offer just such an independent and systematic validation. I report skill scores for the model's predictions of wind speed and interplanetary magnetic field (IMF) polarity for a large set of Carrington rotations. The model was run in all its routinely used configurations. It ingests synoptic line of sight magnetograms. For this study I generated model results for monthly magnetograms from multiple observatories, spanning the Carrington rotation range from 1650 to 2074. I compare the influence of the different magnetogram sources and performance at quiet and active times. I also consider the ability of the WSA model to forecast both sharp transitions in wind speed from slow to fast wind and reversals in the polarity of the radial component of the IMF. These results will serve as a baseline against which to compare future versions of the model as well as the current and future generation of magnetohydrodynamic models under development for forecasting use.

  7. Improved Statistical Sampling and Accuracy with Accelerated Molecular Dynamics on Rotatable Torsions.

    PubMed

    Doshi, Urmi; Hamelberg, Donald

    2012-11-13

    In enhanced sampling techniques, the precision of the reweighted ensemble properties is often decreased due to large variation in statistical weights and reduction in the effective sampling size. To abate this reweighting problem, here, we propose a general accelerated molecular dynamics (aMD) approach in which only the rotatable dihedrals are subjected to aMD (RaMD), unlike the typical implementation wherein all dihedrals are boosted (all-aMD). Nonrotatable and improper dihedrals are marginally important to conformational changes or the different rotameric states. Not accelerating them avoids the sharp increases in the potential energies due to small deviations from their minimum energy conformations and leads to improvement in the precision of RaMD. We present benchmark studies on two model dipeptides, Ace-Ala-Nme and Ace-Trp-Nme, simulated with normal MD, all-aMD, and RaMD. We carry out a systematic comparison between the performances of both forms of aMD using a theory that allows quantitative estimation of the effective number of sampled points and the associated uncertainty. Our results indicate that, for the same level of acceleration and simulation length, as used in all-aMD, RaMD results in significantly less loss in the effective sample size and, hence, increased accuracy in the sampling of φ-ψ space. RaMD yields an accuracy comparable to that of all-aMD, from simulation lengths 5 to 1000 times shorter, depending on the peptide and the acceleration level. Such improvement in speed and accuracy over all-aMD is highly remarkable, suggesting RaMD as a promising method for sampling larger biomolecules.

  8. Experience With Intravascular Ultrasound Imaging Of Human Atherosclerotic Arteries

    NASA Astrophysics Data System (ADS)

    Mallery, John A.; Gessert, James M.; Maciel, Mario; Tobis, John M.; Griffith, James M.; Berns, Michael W.; Henry, Walter L.

    1989-08-01

    Normal human arteries have a well-defined structure on intravascular images. The intima appears very thin and is most likely represented by a bright reflection arising from the internal elastic lamina. The smooth muscle tunica media is echo-lucent on the ultrasound image and appears as a dark band separating the intima from the adventitia. The adventitia is a brightly reflective layer of variable thickness. The thickness of the intima, and therefore of the atherosclerotic plaque can be accurately measured from the ultrasound images and correlates well with histology. Calcification within the wall of arteries is seen as bright echo reflection with shadowing of the peripheral wall. Fibrotic regions are highly reflective but do not shadow. Necrotic liquid regions within advanced atherosclerotic plaques are seen on ultrasound images as large lucent zones surrounded by echogenic tissue. Imaging can be performed before and after interventional procedures, such as laser angioplasty, balloon angioplasty and atherectomy. Intravascular ultrasound appears to provide an imaging modality for identifying the histologic characteristics of diseased arteries and for quantifying plaque thickness. It might be possible to perform such quantification to evaluate the results of interventional procedures.

  9. A report on SHARP (Spacecraft Health Automated Reasoning Prototype) and the Voyager Neptune encounter

    NASA Technical Reports Server (NTRS)

    Martin, R. G. (Editor); Atkinson, D. J.; James, M. L.; Lawson, D. L.; Porta, H. J.

    1990-01-01

    The development and application of the Spacecraft Health Automated Reasoning Prototype (SHARP) for the operations of the telecommunications systems and link analysis functions in Voyager mission operations are presented. An overview is provided of the design and functional description of the SHARP system as it was applied to Voyager. Some of the current problems and motivations for automation in real-time mission operations are discussed, as are the specific solutions that SHARP provides. The application of SHARP to Voyager telecommunications had the goal of being a proof-of-capability demonstration of artificial intelligence as applied to the problem of real-time monitoring functions in planetary mission operations. AS part of achieving this central goal, the SHARP application effort was also required to address the issue of the design of an appropriate software system architecture for a ground-based, highly automated spacecraft monitoring system for mission operations, including methods for: (1) embedding a knowledge-based expert system for fault detection, isolation, and recovery within this architecture; (2) acquiring, managing, and fusing the multiple sources of information used by operations personnel; and (3) providing information-rich displays to human operators who need to exercise the capabilities of the automated system. In this regard, SHARP has provided an excellent example of how advanced artificial intelligence techniques can be smoothly integrated with a variety of conventionally programmed software modules, as well as guidance and solutions for many questions about automation in mission operations.

  10. The stratigraphy and evolution of lower Mount Sharp from spectral, morphological, and thermophysical orbital data sets.

    PubMed

    Fraeman, A A; Ehlmann, B L; Arvidson, R E; Edwards, C S; Grotzinger, J P; Milliken, R E; Quinn, D P; Rice, M S

    2016-09-01

    We have developed a refined geologic map and stratigraphy for lower Mount Sharp using coordinated analyses of new spectral, thermophysical, and morphologic orbital data products. The Mount Sharp group consists of seven relatively planar units delineated by differences in texture, mineralogy, and thermophysical properties. These units are (1-3) three spatially adjacent units in the Murray formation which contain a variety of secondary phases and are distinguishable by thermal inertia and albedo differences, (4) a phyllosilicate-bearing unit, (5) a hematite-capped ridge unit, (6) a unit associated with material having a strongly sloped spectral signature at visible near-infrared wavelengths, and (7) a layered sulfate unit. The Siccar Point group consists of the Stimson formation and two additional units that unconformably overlie the Mount Sharp group. All Siccar Point group units are distinguished by higher thermal inertia values and record a period of substantial deposition and exhumation that followed the deposition and exhumation of the Mount Sharp group. Several spatially extensive silica deposits associated with veins and fractures show that late-stage silica enrichment within lower Mount Sharp was pervasive. At least two laterally extensive hematitic deposits are present at different stratigraphic intervals, and both are geometrically conformable with lower Mount Sharp strata. The occurrence of hematite at multiple stratigraphic horizons suggests redox interfaces were widespread in space and/or in time, and future measurements by the Mars Science Laboratory Curiosity rover will provide further insights into the depositional settings of these and other mineral phases.

  11. Secure Container For Discarded Hypodermic Needles

    NASA Technical Reports Server (NTRS)

    Lee, Angelene M.

    1992-01-01

    Container designed for safe retention of discarded blood-collecting hypodermic needles and similar sharp objects used in life-science experiments aboard spacecraft. Needles inserted through self-closing lid and retained magnetically. They are inserted, sharp end first, through spring-loaded flap. Long needles and needles on syringes cannot turn around in container. Can be emptied, cleaned, and reused. Used on Earth to provide unusually secure containment of sharp objects.

  12. Injuries caused by sharp instruments among healthcare workers--international and Polish perspectives.

    PubMed

    Goniewicz, Mariusz; Włoszczak-Szubzda, Anna; Niemcewicz, Marcin; Witt, Magdalena; Marciniak-Niemcewicz, Anna; Jarosz, Mirosław Jerzy

    2012-01-01

    Health care workers (HCW) worldwide are especially exposed to injury by sharp instruments in the course of their duty. The most often executed procedures with injury risk are: intramuscular or subcutaneous injection (22%), taking blood samples, or during intravenous cannulation (20%), and repeatedly replacing the cap on an already used needle (30%). Even a minor sharp injury with only a small loss of blood carries the risk of transfer of over 20 pathogens: Hepatitis B Virus (HBV), Hepatitis C Virus (HCV), HIV/AIDS virus, malaria, syphilis, tuberculosis, brucellosis, herpes virus and diphtheria. The World Health Organization (WHO) estimates that more than two million health care workers experience the stressful event of a percutaneous injury with a contaminated sharp object each year (25-90% of them, however, remain unreported). These exposures result in about 16,000 infections with HCV, 66,000 with HBV and about 1,000 (200-5000) with HIV, which lead to about 1,100 deaths or significant disability. Exposures to sharp injuries and their consequences are highly preventable through simple interventions, such as HBV vaccination, education and providing containers for sharp instruments. Specific guidelines, similar to the American Occupational Safety and Health Administration (OSHA) regulations that have lowered by up to 88% of needle stabbing incidents, should be introduced by the European Union (EU) and other countries. The results of a review of reports leads to the following conclusions: 1) elaboration and implementation of new State regulations, especially in EU countries and in countries where such regulations do not exist; 2) the training of health care personnel should always be undertaken for new employees, and periodically for those already employed; 3) periodical control by appointed inspectors of knowledge of procedures for the prevention of injuries by sharp instruments among health care workers; 4) introducing and training in the use of equipment, which can prevent the sharp injuries; 5) an advanced monitoring system of sharp injuries sustained by worker should also be introduced. Successful implementation of these prevention measures will result in progress for public health and HCW's health and safety.

  13. Surface-Wave Pulse Routing around Sharp Right Angles

    NASA Astrophysics Data System (ADS)

    Gao, Z.; Xu, H.; Gao, F.; Zhang, Y.; Luo, Y.; Zhang, B.

    2018-04-01

    Surface-plasmon polaritons (SPPs), or localized electromagnetic surface waves propagating on a metal-dielectric interface, are deemed promising information carriers for future subwavelength terahertz and optical photonic circuitry. However, surface waves fundamentally suffer from scattering loss when encountering sharp corners in routing and interconnection of photonic signals. Previous approaches enabling scattering-free surface-wave guidance around sharp corners are limited to either volumetric waveguide environments or extremely narrow bandwidth, being unable to guide a surface-wave pulse (SPP wave packet) on an on-chip platform. Here, in a surface-wave band-gap crystal implemented on a single metal surface, we demonstrate in time-domain routing a surface-wave pulse around multiple sharp right angles without perceptible scattering. Our work not only offers a solution to on-chip surface-wave pulse routing along an arbitrary path, but it also provides spatiotemporal information on the interplay between surface-wave pulses and sharp corners, both of which are desirable in developing high-performance large-scale integrated photonic circuits.

  14. Predictors of failure and success of tibial interventions for critical limb ischemia.

    PubMed

    Fernandez, Nathan; McEnaney, Ryan; Marone, Luke K; Rhee, Robert Y; Leers, Steven; Makaroun, Michel; Chaer, Rabih A

    2010-10-01

    The efficacy of tibial artery endovascular intervention (TAEI) for critical limb ischemia (CLI) and particularly for wound healing is not fully defined. The purpose of this study is to determine predictors of failure and success for TAEI in the setting of CLI. All TAEI for tissue loss or rest pain (Rutherford classes 4, 5, and 6) from 2004 to 2008 were retrospectively reviewed. Clinical outcomes and patency rates were analyzed by multivariable Cox proportional hazards regression and life table analysis. One hundred twenty-three limbs in 111 patients (62% male, mean age 74) were treated. Sixty-seven percent of patients were diabetics, 55% had renal insufficiency, and 21% required hemodialysis. One hundred two limbs (83%) exhibited tissue loss; all others had ischemic rest pain. All patients underwent tibial angioplasty (PTA). Tibial excimer laser atherectomy was performed in 14% of the patients. Interventions were performed on multiple tibial vessels in 20% of limbs. Isolated tibial procedures were performed on 50 limbs (41%), while 73 patients had concurrent ipsilateral superficial femoral artery or popliteal interventions. The mean distal popliteal and tibial runoff score improved from 11.8 ± 3.6 to 6.7 ± 1.6 (P < .001), and the mean ankle-brachial index increased from 0.61 ± 0.26 to 0.85 ± 0.22 (P < .001). Surgical bypass was required in seven patients (6%). The mean follow up was 6.8 ± 6.6 months, while the 1-year primary, primary-assisted, and secondary patency rates were 33%, 50%, and 56% respectively. Limb salvage rate at 1 year was 75%. Factors found to be associated with impaired limb salvage included renal insufficiency (hazard ratio [HR] = 5.7; P = .03) and the need for pedal intervention (HR = 13.75; P = .04). TAEI in an isolated peroneal artery (odds ratio = 7.80; P = .01) was associated with impaired wound healing, whereas multilevel intervention (HR = 2.1; P = .009) and tibial laser atherectomy (HR = 3.1; P = .01) were predictors of wound healing. In patients with tissue loss, 41% achieved complete closure (mean time to healing, 10.7 ± 7.4 months), and 39% exhibited partial wound healing (mean follow up, 4.4 ± 4.8 months) at last follow up. Diabetes, smoking, statin therapy, and revascularization of > 1 tibial vessel had no impact on limb salvage or wound healing. Re-intervention rate was 50% at 1 year. TAEI is an effective treatment for CLI with acceptable limb salvage and wound healing rates, but requires a high rate of reintervention. Patients with renal failure, pedal disease, or isolated peroneal runoff have poor outcomes with TAEI and should be considered for surgical bypass. Copyright © 2010 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  15. 16 CFR 1500.48 - Technical requirements for determining a sharp point in toys and other articles intended for use...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... sharp point in toys and other articles intended for use by children under 8 years of age. 1500.48... requirements for determining a sharp point in toys and other articles intended for use by children under 8... intended for use by children under 8 years of age, and such points exposed in normal use or as a result of...

  16. 16 CFR § 1500.48 - Technical requirements for determining a sharp point in toys and other articles intended for use...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... sharp point in toys and other articles intended for use by children under 8 years of age. § 1500.48... by children under 8 years of age. (a) Objective. The sharp point test prescribed by paragraph (d) of... and other articles intended for use by children under 8 years of age, and such points exposed in...

  17. 16 CFR 1500.48 - Technical requirements for determining a sharp point in toys and other articles intended for use...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... sharp point in toys and other articles intended for use by children under 8 years of age. 1500.48... requirements for determining a sharp point in toys and other articles intended for use by children under 8... intended for use by children under 8 years of age, and such points exposed in normal use or as a result of...

  18. 16 CFR 1500.48 - Technical requirements for determining a sharp point in toys and other articles intended for use...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... sharp point in toys and other articles intended for use by children under 8 years of age. 1500.48... requirements for determining a sharp point in toys and other articles intended for use by children under 8... intended for use by children under 8 years of age, and such points exposed in normal use or as a result of...

  19. Investigation of micromixing by acoustically oscillated sharp-edges

    PubMed Central

    Nama, Nitesh; Huang, Po-Hsun; Huang, Tony Jun; Costanzo, Francesco

    2016-01-01

    Recently, acoustically oscillated sharp-edges have been utilized to achieve rapid and homogeneous mixing in microchannels. Here, we present a numerical model to investigate acoustic mixing inside a sharp-edge-based micromixer in the presence of a background flow. We extend our previously reported numerical model to include the mixing phenomena by using perturbation analysis and the Generalized Lagrangian Mean (GLM) theory in conjunction with the convection-diffusion equation. We divide the flow variables into zeroth-order, first-order, and second-order variables. This results in three sets of equations representing the background flow, acoustic response, and the time-averaged streaming flow, respectively. These equations are then solved successively to obtain the mean Lagrangian velocity which is combined with the convection-diffusion equation to predict the concentration profile. We validate our numerical model via a comparison of the numerical results with the experimentally obtained values of the mixing index for different flow rates. Further, we employ our model to study the effect of the applied input power and the background flow on the mixing performance of the sharp-edge-based micromixer. We also suggest potential design changes to the previously reported sharp-edge-based micromixer to improve its performance. Finally, we investigate the generation of a tunable concentration gradient by a linear arrangement of the sharp-edge structures inside the microchannel. PMID:27158292

  20. Investigation of micromixing by acoustically oscillated sharp-edges.

    PubMed

    Nama, Nitesh; Huang, Po-Hsun; Huang, Tony Jun; Costanzo, Francesco

    2016-03-01

    Recently, acoustically oscillated sharp-edges have been utilized to achieve rapid and homogeneous mixing in microchannels. Here, we present a numerical model to investigate acoustic mixing inside a sharp-edge-based micromixer in the presence of a background flow. We extend our previously reported numerical model to include the mixing phenomena by using perturbation analysis and the Generalized Lagrangian Mean (GLM) theory in conjunction with the convection-diffusion equation. We divide the flow variables into zeroth-order, first-order, and second-order variables. This results in three sets of equations representing the background flow, acoustic response, and the time-averaged streaming flow, respectively. These equations are then solved successively to obtain the mean Lagrangian velocity which is combined with the convection-diffusion equation to predict the concentration profile. We validate our numerical model via a comparison of the numerical results with the experimentally obtained values of the mixing index for different flow rates. Further, we employ our model to study the effect of the applied input power and the background flow on the mixing performance of the sharp-edge-based micromixer. We also suggest potential design changes to the previously reported sharp-edge-based micromixer to improve its performance. Finally, we investigate the generation of a tunable concentration gradient by a linear arrangement of the sharp-edge structures inside the microchannel.

  1. Sample Skewness as a Statistical Measurement of Neuronal Tuning Sharpness

    PubMed Central

    Samonds, Jason M.; Potetz, Brian R.; Lee, Tai Sing

    2014-01-01

    We propose using the statistical measurement of the sample skewness of the distribution of mean firing rates of a tuning curve to quantify sharpness of tuning. For some features, like binocular disparity, tuning curves are best described by relatively complex and sometimes diverse functions, making it difficult to quantify sharpness with a single function and parameter. Skewness provides a robust nonparametric measure of tuning curve sharpness that is invariant with respect to the mean and variance of the tuning curve and is straightforward to apply to a wide range of tuning, including simple orientation tuning curves and complex object tuning curves that often cannot even be described parametrically. Because skewness does not depend on a specific model or function of tuning, it is especially appealing to cases of sharpening where recurrent interactions among neurons produce sharper tuning curves that deviate in a complex manner from the feedforward function of tuning. Since tuning curves for all neurons are not typically well described by a single parametric function, this model independence additionally allows skewness to be applied to all recorded neurons, maximizing the statistical power of a set of data. We also compare skewness with other nonparametric measures of tuning curve sharpness and selectivity. Compared to these other nonparametric measures tested, skewness is best used for capturing the sharpness of multimodal tuning curves defined by narrow peaks (maximum) and broad valleys (minima). Finally, we provide a more formal definition of sharpness using a shape-based information gain measure and derive and show that skewness is correlated with this definition. PMID:24555451

  2. The stratigraphy and evolution of lower Mount Sharp from spectral, morphological, and thermophysical orbital data sets

    PubMed Central

    Ehlmann, B. L.; Arvidson, R. E.; Edwards, C. S.; Grotzinger, J. P.; Milliken, R. E.; Quinn, D. P.; Rice, M. S.

    2016-01-01

    Abstract We have developed a refined geologic map and stratigraphy for lower Mount Sharp using coordinated analyses of new spectral, thermophysical, and morphologic orbital data products. The Mount Sharp group consists of seven relatively planar units delineated by differences in texture, mineralogy, and thermophysical properties. These units are (1–3) three spatially adjacent units in the Murray formation which contain a variety of secondary phases and are distinguishable by thermal inertia and albedo differences, (4) a phyllosilicate‐bearing unit, (5) a hematite‐capped ridge unit, (6) a unit associated with material having a strongly sloped spectral signature at visible near‐infrared wavelengths, and (7) a layered sulfate unit. The Siccar Point group consists of the Stimson formation and two additional units that unconformably overlie the Mount Sharp group. All Siccar Point group units are distinguished by higher thermal inertia values and record a period of substantial deposition and exhumation that followed the deposition and exhumation of the Mount Sharp group. Several spatially extensive silica deposits associated with veins and fractures show that late‐stage silica enrichment within lower Mount Sharp was pervasive. At least two laterally extensive hematitic deposits are present at different stratigraphic intervals, and both are geometrically conformable with lower Mount Sharp strata. The occurrence of hematite at multiple stratigraphic horizons suggests redox interfaces were widespread in space and/or in time, and future measurements by the Mars Science Laboratory Curiosity rover will provide further insights into the depositional settings of these and other mineral phases. PMID:27867788

  3. Relationship between sharps disposal containers and Clostridium difficile infections in acute care hospitals.

    PubMed

    Pogorzelska-Maziarz, Monika

    2015-10-01

    Sharps disposal containers are ubiquitous in health care facilities; however, there is paucity of data on their potential role in pathogen transmission. This study assessed the relationship between use of single-use versus reusable sharps containers and rates of Clostridium difficile infections in a national sample of hospitals. A 2013 survey of 1,990 hospitals collected data on the use of sharps containers. Responses were linked to the 2012 Medicare Provider Analysis and Review dataset. Bivariate and multivariable negative binomial regression were conducted to examine differences in C difficile rates between hospitals using single-use versus reusable containers. There were 604 hospitals who completed the survey; of these, 539 provided data on use of sharps containers in 2012 (27% response rate). Hospitals had, on average, 289 beds (SD ± 203) and were predominantly non-for-profit (67%) and nonteaching (63%). Most used reusable sharps containers (72%). In bivariate regression, hospitals using single-use containers had significantly lower rates of C difficile versus hospitals using reusable containers (incidence rate ratio [IRR] = 0.846, P = .001). This relationship persisted in multivariable regression (IRR = 0.870, P = .003) after controlling for other hospital characteristics. This is the first study to show a link between use of single-use sharps containers and lower C difficile rates. Future research should investigate the potential for environmental contamination of reusable containers and the role they may play in pathogen transmission. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  4. Risk of Potential Exposure Incident in Non-healthcare Workers in Contact with Infectious and Municipal Waste

    PubMed Central

    Kanisek, Sanja; Gmajnić, Rudika; Barać, Ivana

    2018-01-01

    Abstract Introduction The proper classification of sharp and infectious waste in situ by the healthcare workers is an important measure of prevention of sharps and other exposure incidents in non-healthcare workers, who handle such waste. The aim was to examine the practice of classifying sharp and infectious waste in family and dental practices. Methods An analysis of 50 bags of infectious and 50 bags of municipal waste from five family and five dental practices for five days in October 2016 at the Health centre Osijek. Results Healthcare workers in 70% of the practices deposited sharps in infectious waste. In 56% of infectious waste bags, sharp object were found. More risky bags of infectious waste were produced by family practices (64%), but with no significant differences in relation to dental practices (48%), (P=0.143). Disposing of infectious into municipal waste was the case in 90% of the practitioners, where in 60% of municipal waste bags, infectious waste was disposed. Dental practices produced more risky bags of municipal waste (76%) in relation to family practices (44%), but with no significant difference (P=0.714). Conclusions The results of this research point to importance of performing audits of proper disposal of sharps and infectious waste to reduce the risks of injury to non-healthcare workers who come into contact with the said waste. Given results could be used for framing written protocols of proper disposal of sharps and infectious waste that should be visibly available in family and dental practices and for education of healthcare workers. PMID:29651317

  5. The Einstein soft X-ray survey of the Pleiades

    NASA Technical Reports Server (NTRS)

    Caillault, J.-P.; Helfand, D. J.

    1985-01-01

    The results of a 0.1-4.5-keV X-ray survey of a 2 x 2-deg area centered on the Pleiades open cluster, performed using the imaging proportional counter and high-resolution imager of the Einstein Observatory on four days in 1980-1981, are presented in extensive tables, graphs, maps, histograms, and finding charts and characterized. A total of 61 sources are detected, and 44 of these are identified with cluster members of spectral types B-M. Findings discussed include Lx/Lbol of 10 the -7th for early-type stars; F-star mean Lx like that of F stars in the Hyades and in the field (denying time evolution of Lx); mean G-star Lx = 3.7 x 10 to the 29th erg/sec; G-star activity decay more gradual than 1/sq rt t, with sharp fall for t greater than 1 Gyr; and no evidence for X-ray-emissivity/rotational-velocity correlation in a homogeneous sample of K dwarfs or a sample of K and M stars with established V sin i data.

  6. Suprascapular neuropathy after intensive progressive resistive exercise: case report.

    PubMed

    Agre, J C; Ash, N; Cameron, M C; House, J

    1987-04-01

    A healthy 30-year-old man developed pain in the posterior shoulder region approximately one month after initiating an intensive weightlifting program to increase upper extremity strength. This program especially emphasized shoulder abduction exercises. The pain intensified as he continued and finally he noted weakness of the involved shoulder, which led him to seek medical advice. Examination was normal except for atrophy of the infraspinatus muscle on the involved side and decreased strength of shoulder abduction and external rotation. Electromyographic examination demonstrated 3+ positive sharp waves in the infraspinatus muscle, delayed conduction to the supraspinatus muscle, and absence of an evoked response to the infraspinatus muscle. Surgical decompression of the suprascapular nerve within the suprascapular notch was then performed. Two weeks after surgery the pain was much less and the conduction velocities had improved. Eight months after surgery the patient was free of pain, the conduction velocities had returned to normal, and electromyography revealed reinnervation of the denervated muscle fibers. Intensive shoulder exercise, especially involving repeated forceful abduction movements, should be considered in the etiology of suprascapular neuropathy.

  7. XFEL diffraction: Developing processing methods to optimize data quality

    DOE PAGES

    Sauter, Nicholas K.

    2015-01-29

    Serial crystallography, using either femtosecond X-ray pulses from free-electron laser sources or short synchrotron-radiation exposures, has the potential to reveal metalloprotein structural details while minimizing damage processes. However, deriving a self-consistent set of Bragg intensities from numerous still-crystal exposures remains a difficult problem, with optimal protocols likely to be quite different from those well established for rotation photography. Here several data processing issues unique to serial crystallography are examined. It is found that the limiting resolution differs for each shot, an effect that is likely to be due to both the sample heterogeneity and pulse-to-pulse variation in experimental conditions. Shotsmore » with lower resolution limits produce lower-quality models for predicting Bragg spot positions during the integration step. Also, still shots by their nature record only partial measurements of the Bragg intensity. An approximate model that corrects to the full-spot equivalent (with the simplifying assumption that the X-rays are monochromatic) brings the distribution of intensities closer to that expected from an ideal crystal, and improves the sharpness of anomalous difference Fourier peaks indicating metal positions.« less

  8. Launch pad lightning protection effectiveness

    NASA Technical Reports Server (NTRS)

    Stahmann, James R.

    1991-01-01

    Using the striking distance theory that lightning leaders will strike the nearest grounded point on their last jump to earth corresponding to the striking distance, the probability of striking a point on a structure in the presence of other points can be estimated. The lightning strokes are divided into deciles having an average peak current and striking distance. The striking distances are used as radii from the points to generate windows of approach through which the leader must pass to reach a designated point. The projections of the windows on a horizontal plane as they are rotated through all possible angles of approach define an area that can be multiplied by the decile stroke density to arrive at the probability of strokes with the window average striking distance. The sum of all decile probabilities gives the cumulative probability for all strokes. The techniques can be applied to NASA-Kennedy launch pad structures to estimate the lightning protection effectiveness for the crane, gaseous oxygen vent arm, and other points. Streamers from sharp points on the structure provide protection for surfaces having large radii of curvature. The effects of nearby structures can also be estimated.

  9. Electrochemical way of molybdenum extraction from the Bimetallic systems of Mo-W

    NASA Astrophysics Data System (ADS)

    Kudreeva, L. K.; Nauryzbaev, M. K.; Kurbatov, A. P.; Kamysbaev, D. H.; Adilbekova, A. O.; Mukataeva, Z. S.

    2015-12-01

    Electrochemical dissolution of molybdenum and tungsten was investigated in water- dimethylsulfoxide (DMSO) media at different concentrations of lithium chloride and magnesium perchlorate. The terms of efficient extraction of molybdenum from bimetallic systems of Mo-W have been determined. The polarization curves of the electrooxidation of molybdenum in the solution of 0.25 M LiCl in the DMSO at the different rates of rotations and the scan rate equal to 50 mV/s were obtained. In the presence of the addition of water at the potential of 0.1-0.75 V the small area of polarizability occurs, then with increasing potentials above 1.5 V there is a sharp increase of the oxidation current. Comparison of the current values of anodic dissolution of molybdenum and tungsten showed that the rate of anodic dissolution of molybdenum significantly exceeds the rate of anodic dissolution of tungsten. In the case of molybdenum, the dissolution process is limited by diffusion, in the case of tungsten - by the passive film formation on the electrode surface.

  10. A study of X-ray multiple diffraction by means of section topography.

    PubMed

    Kohn, V G; Smirnova, I A

    2015-09-01

    The results of theoretical and experimental study are presented for the question of how the X-ray multiple diffraction in a silicon single crystal influences the interference fringes of section topography for the 400 reflection in the Laue case. Two different cases of multiple diffraction are discovered for zero and very small values of the azimuthal angle for the sample in the form of a plate with the surface normal to the 001 direction. The cases are seen on the same topogram without rotation of the crystal. Accurate computer simulations of the section topogram for the case of X-ray multiple diffraction are performed for the first time. It is shown that the structure of interference fringes on the section topogram in the region of multiple diffraction becomes more complicated. It has a very sharp dependence on the azimuthal angle. The experiment is carried out using a laboratory source under conditions of low resolution over the azimuthal angle. Nevertheless, the characteristic inclination of the interference fringes on the tails of the multiple diffraction region is easily seen. This phenomenon corresponds completely to the computer simulations.

  11. Viscosity Measurements of "FeO"-SiO2 Slag in Equilibrium with Metallic Fe

    NASA Astrophysics Data System (ADS)

    Chen, Mao; Raghunath, Sreekanth; Zhao, Baojun

    2013-06-01

    The current study delivered the measurements of viscosities in the system "FeO"-SiO2 in equilibrium with metallic Fe in the composition range between 15 and 40 wt pct SiO2. The experiments were carried out in the temperature range of 1473 K to 1773 K (1200 °C to 1500 °C) using a rotational spindle technique. An analysis of the quenched sample by electron probe X-ray microanalysis (EPMA) after the viscosity measurement enables the composition and microstructure of the slag to be directly linked with the viscosity. The current results are compared with available literature data. The significant discrepancies of the viscosity measurements in this system have been clarified. The possible reasons affecting the accuracy of the viscosity measurement have been discussed. The activation energies derived from the experimental data have a sharp increase at about 33 wt pct SiO2, which corresponds to the composition of fayalite (Fe2SiO4). The modified quasi-chemical model was constructed in the system "FeO"-SiO2 to describe the current viscosity data.

  12. Kerr black holes with scalar hair.

    PubMed

    Herdeiro, Carlos A R; Radu, Eugen

    2014-06-06

    We present a family of solutions of Einstein's gravity minimally coupled to a complex, massive scalar field, describing asymptotically flat, spinning black holes with scalar hair and a regular horizon. These hairy black holes (HBHs) are supported by rotation and have no static limit. Besides mass M and angular momentum J, they carry a conserved, continuous Noether charge Q measuring the scalar hair. HBHs branch off from the Kerr metric at the threshold of the superradiant instability and reduce to spinning boson stars in the limit of vanishing horizon area. They overlap with Kerr black holes for a set of (M, J) values. A single Killing vector field preserves the solutions, tangent to the null geodesic generators of the event horizon. HBHs can exhibit sharp physical differences when compared to the Kerr solution, such as J/M^{2}>1, a quadrupole moment larger than J^{2}/M, and a larger orbital angular velocity at the innermost stable circular orbit. Families of HBHs connected to the Kerr geometry should exist in scalar (and other) models with more general self-interactions.

  13. Strong interplay between stripe spin fluctuations, nematicity and superconductivity in FeSe

    DOE PAGES

    Wang, Qisi; Shen, Yao; Pan, Bingying; ...

    2015-12-07

    In iron-based superconductors the interactions driving the nematic order (that breaks four-fold rotational symmetry in the iron plane) may also mediate the Cooper pairing. The experimental determination of these interactions, which are believed to depend on the orbital or the spin degrees of freedom, is challenging because nematic order occurs at, or slightly above, the ordering temperature of a stripe magnetic phase. In this paper, we study FeSe—which exhibits a nematic (orthorhombic) phase transition at T s = 90 K without antiferromagnetic ordering—by neutron scattering, finding substantial stripe spin fluctuations coupled with the nematicity that are enhanced abruptly on coolingmore » through T s. A sharp spin resonance develops in the superconducting state, whose energy (~4 meV) is consistent with an electron–boson coupling mode revealed by scanning tunnelling spectroscopy. The magnetic spectral weight in FeSe is found to be comparable to that of the iron arsenides. Finally, our results support recent theoretical proposals that both nematicity and superconductivity are driven by spin fluctuations.« less

  14. Strong interplay between stripe spin fluctuations, nematicity and superconductivity in FeSe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Qisi; Shen, Yao; Pan, Bingying

    In iron-based superconductors the interactions driving the nematic order (that breaks four-fold rotational symmetry in the iron plane) may also mediate the Cooper pairing. The experimental determination of these interactions, which are believed to depend on the orbital or the spin degrees of freedom, is challenging because nematic order occurs at, or slightly above, the ordering temperature of a stripe magnetic phase. In this paper, we study FeSe—which exhibits a nematic (orthorhombic) phase transition at T s = 90 K without antiferromagnetic ordering—by neutron scattering, finding substantial stripe spin fluctuations coupled with the nematicity that are enhanced abruptly on coolingmore » through T s. A sharp spin resonance develops in the superconducting state, whose energy (~4 meV) is consistent with an electron–boson coupling mode revealed by scanning tunnelling spectroscopy. The magnetic spectral weight in FeSe is found to be comparable to that of the iron arsenides. Finally, our results support recent theoretical proposals that both nematicity and superconductivity are driven by spin fluctuations.« less

  15. Sediment Scaling for Mud Mountain Fish Barrier Structure

    DTIC Science & Technology

    2017-06-28

    2nd Int. Conf. on the Application of Physical Modeling to Port and Coastal Protection – Coastlab ’08, International Association for Hydro...Structure by Jeremy A. Sharp, Gary L. Brown, and Gary L. Bell PURPOSE: This Coastal and Hydraulics Laboratory technical note describes the process of... Coastal and Hydraulics Laboratory. Questions about this technical note can be addressed to Mr. Sharp at 601-634-4212 or Jeremy.A.Sharp@usace.army.mil

  16. A faunistic study of genus Chasmogenus Sharp, 1882 of China (Coleoptera, Hydrophilidae).

    PubMed

    Jia, Fenglong; Tang, Yu-Dan

    2018-01-01

    Chasmogenus Sharp, 1882 is newly reported from the Chinese Mainland. A new species, C. parorbus sp. n. , is described from China (Yunnan). Chasmogenus orbus Watanabe, 1987 is reported from Hong Kong, the first record outside Japan. Chasmogenus abnormalis (Sharp, 1890) is reported from the Chinese mainland for the first time. The male genitalia of each species are illustrated. A key to the Chinese species of the genus is provided.

  17. Novel Laser-Based Technique for Measurements of Primary Atomization Characteristics of Liquid Jets

    DTIC Science & Technology

    2012-08-22

    worth noting that round supercavitating nozzles were used that had sharp edged inlets and exits, with length-to-diameter ratios smaller than 3. This...noting that round supercavitating nozzles were used that had sharp edged inlets and exits, with length-to-diameter ratios smaller than 3. This...breakup. It is worth noting that round supercavitating nozzles were used that had sharp edged inlets and exits, with length-to-diameter ratios

  18. Occurrence of Greater Sage-Grouse X Sharp-tailed Grouse hybrids in Alberta

    USGS Publications Warehouse

    Aldridge, Cameron L.; Oyler-McCance, S.J.; Brigham, R.M.

    2001-01-01

    Two distinct grouse were regularly observed at two Greater Sage-Grouse (Centrocercus urophasianus) leks in both 1999 and 2000 in southeastern Alberta. Physically and behaviorally, the birds exhibited characteristics of both Greater Sage-Grouse and Sharp-tailed Grouse (Tympanuchus phasianellus), suggesting they were hybrids. DNA analyses of blood and feather samples indicated that both birds were males with Greater Sage-Grouse mothers and thus, fathers that were likely Sharp-tailed Grouse.

  19. UHTC Research at NASA Ames

    NASA Technical Reports Server (NTRS)

    Johnson, Sylvia M.

    2011-01-01

    For enhanced aerodynamic performance. Materials for sharp leading edges can be reusable but need different properties because of geometry and very high temperatures. Require materials with significantly higher temperature capabilities, but for short duration. Current shuttle RCC leading edge materials: T approx. 1650 C. Materials for vehicles with sharp leading edges: T>2000 C. >% Figure depicts: High Temperature at Tip and Steep Temperature Gradient. Passive cooling is simplest option to manage the intense heating on sharp leading edges.

  20. Testing local-realism and macro-realism under generalized dichotomic measurements

    NASA Astrophysics Data System (ADS)

    Das, Debarshi; Mal, Shiladitya; Home, Dipankar

    2018-04-01

    Generalized quantum measurements with two outcomes are fully characterized by two real parameters, dubbed as sharpness parameter and biasedness parameter and they can be linked with different aspects of the experimental setup. It is known that sharpness parameter characterizes precision of the measurements and decreasing sharpness parameter of the measurements reduces the possibility of probing quantum features like quantum mechanical (QM) violation of local-realism (LR) or macro-realism (MR). Here we investigate the effect of biasedness together with that of sharpness of measurements and find a trade-off between those two parameters in the context of probing QM violations of LR and MR. Interestingly, we also find that the above mentioned trade-off is more robust in the latter case.